WorldWideScience

Sample records for single-shot echo-planar imaging

  1. Single-shot echo-planar imaging of multiple sclerosis: effects of varying echo time

    International Nuclear Information System (INIS)

    Wolansky, L.J.; Chong, S.; Liu, W.C.; Kang, E.; Simpson, S.W.; Karimi, S.; Akbari, H.

    1999-01-01

    Our aim was to determine the relative merits of short and long echo times (TE) with single-shot echo-planar imaging for imaging cerebral lesions such as multiple sclerosis. We examined seven patients with clinically definite multiple sclerosis were imaged at 1.5 T. Patients were scanned with spin-echo, single-shot echo-planar imaging, using TEs of 45, 75, 105, and 135 ms. Region of interest (ROI) measurements were performed on 36 lesions at or above the level of the corona radiata. The mean image contrast (IC) was highest (231.1) for a TE of 45 ms, followed by 75 ms (218.9), 105 ms (217.9), and 135 ms (191.6). When mean contrast-to-noise ratios (C/N) were compared, the value was again highest (29.7) for TE 45 ms, followed by 75 ms (28.9), 105 ms (28.5), and 135 ms (26.3). In a lesion-by-lesion comparison, TE 45 ms had the highest IC and C/N in the largest number of cases (50 % and 47.2 %, respectively). IC and C/N for TE 45 ms were superior to those of 75 ms in 64 % and 58 %, respectively. These results support the use of relatively short TEs for single-shot echo-planar imaging in the setting of cerebral lesions such as multiple sclerosis. (orig.) (orig.)

  2. Ultrafast bold fMRI using single-shot spin-echo echo planar imaging

    Directory of Open Access Journals (Sweden)

    Boujraf Said

    2009-01-01

    Full Text Available The choice of imaging parameters for functional MRI can have an impact on the accuracy of functional localization by affecting the image quality and the degree of blood oxygenation-dependent (BOLD contrast achieved. By improving sampling efficiency, parallel acquisition techniques such as sensitivity encoding (SENSE have been used to shorten readout trains in single-shot (SS echo planar imaging (EPI. This has been applied to susceptibility artifact reduction and improving spatial resolution. SENSE together with single-shot spin-echo (SS-SE imaging may also reduce off-resonance artifacts. The goal of this work was to investigate the BOLD response of a SENSE-adapted SE-EPI on a three Tesla scanner. Whole-brain fMRI studies of seven healthy right hand-dominant volunteers were carried out in a three Tesla scanner. fMRI was performed using an SS-SE EPI sequence with SENSE. The data was processed using statistical parametric mapping. Both, group and individual subject data analyses were performed. Individual average percentage and maximal percentage signal changes attributed to the BOLD effect in M1 were calculated for all the subjects as a function of echo time. Corresponding activation maps and the sizes of the activated clusters were also calculated. Our results show that susceptibility artifacts were reduced with the use of SENSE; and the acquired BOLD images were free of the typical quadrature artifacts of SS-EPI. Such measures are crucial at high field strengths. SS SE-EPI with SENSE offers further benefits in this regard and is more specific for oxygenation changes in the microvasculature bed. Functional brain activity can be investigated with the help of single-shot spin echo EPI using SENSE at high magnetic fields.

  3. Readout-Segmented Echo-Planar Imaging in Diffusion-Weighted MR Imaging in Breast Cancer: Comparison with Single-Shot Echo-Planar Imaging in Image Quality

    International Nuclear Information System (INIS)

    Kim, Yun Ju; Kim, Sung Hun; Kang, Bong Joo; Park, Chang Suk; Kim, Hyeon Sook; Son, Yo Han; Porter, David Andrew; Song, Byung Joo

    2014-01-01

    The purpose of this study was to compare the image quality of standard single-shot echo-planar imaging (ss-EPI) and that of readout-segmented EPI (rs-EPI) in patients with breast cancer. Seventy-one patients with 74 breast cancers underwent both ss-EPI and rs-EPI. For qualitative comparison of image quality, three readers independently assessed the two sets of diffusion-weighted (DW) images. To evaluate geometric distortion, a comparison was made between lesion lengths derived from contrast enhanced MR (CE-MR) images and those obtained from the corresponding DW images. For assessment of image parameters, signal-to-noise ratio (SNR), lesion contrast, and contrast-to-noise ratio (CNR) were calculated. The rs-EPI was superior to ss-EPI in most criteria regarding the qualitative image quality. Anatomical structure distinction, delineation of the lesion, ghosting artifact, and overall image quality were significantly better in rs-EPI. Regarding the geometric distortion, lesion length on ss-EPI was significantly different from that of CE-MR, whereas there were no significant differences between CE-MR and rs-EPI. The rs-EPI was superior to ss-EPI in SNR and CNR. Readout-segmented EPI is superior to ss-EPI in the aspect of image quality in DW MR imaging of the breast

  4. Diffusion-weighted single shot echo planar imaging of colorectal cancer using a sensitivity-encoding technique

    International Nuclear Information System (INIS)

    Nasu, Katsuhiro; Kuroki, Yoshihumi; Murakami, Koji; Nawano, Shigeru; Kuroki, Seiko; Moriyama, Noriyuki

    2004-01-01

    We wanted to determine the feasibility of diffusion-weighted single shot echo planar imaging using a sensitivity encoding diffusion weighted imaging (SENSE-DWI) technique in depicting colorectal cancer. Forty-two patients with sigmoid colon cancer and rectal cancer, all proven pathologically, were examined on T2-turbo spin echo (TSE) and SENSE-DWI. No bowel preparation was performed before examination. The b-factors used in SENSE-DWI were zero and 1000 s/mm 2 . In 10 randomly selected cases, the images whose b-factors were 250 and 500 s/mm 2 were also obtained. The reduction factor of SENSE was 2.0 in all sequences. Two radiologists evaluated the obtained images from the viewpoints of tumor detectability, image distortion and misregistration of the tumors. The apparent diffusion coefficients (ADCs) of the tumors and urine in the urinary bladders in each patient were measured to evaluate the correlation between ADC and pathological classification of each tumor. All tumors were depicted hyperintensely on SENSE-DWI. Even though single shot echo planar imaging (EPI) was used, the image distortion and misregistration was quite pronounced because of simultaneous use of SENSE. On SENSE-DWI whose b-factor was 1000 s/mm 2 , the normal colon wall and feces were always hypointense and easily differentiated from the tumors. The mean ADC value of each tumor was 1.02±0.1 (x 10 -3 ) mm 2 /s. No overt correlation can be pointed out between ADC and pathological classification of each tumor. SENSE-DWI is a feasible method for depicting colorectal cancer. SENSE-DWI provides strong contrast among colorectal cancers, normal rectal wall and feces. (authors)

  5. Readout-segmented echo-planar imaging improves the image quality of diffusion-weighted MR imaging in rectal cancer: Comparison with single-shot echo-planar diffusion-weighted sequences

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Chun-chao; Liu, Xi; Peng, Wan-lin; Li, Lei; Zhang, Jin-ge [Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Meng, Wen-jian; Deng, Xiang-bing [Department of Gastrointestinal Surgery, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Zuo, Pan-li [Siemens Healthcare, MR Collaborations NE Asia, 100010, Beijing (China); Li, Zhen-lin, E-mail: lzlcd01@126.com [Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China)

    2016-10-15

    Purpose: To determine whether readout-segmented echo-planar imaging (rs-EPI) diffusion-weighted imaging (DWI) can improve the image quality in patients with rectal cancer compared with single-shot echo-planar imaging (ss-EPI) DWI using 3.0 T magnetic resonance (MR) imaging. Materials and methods: This study was approved by the Institutional Review Board, and informed consent was obtained from all patients. Seventy-one patients with rectal cancer were enrolled in this study. For all patients, both rs-EPI and ss-EPI DWI were performed using a 3T MR scanner. Two radiologists independently assessed the overall image quality, lesion conspicuity, geometric distortion and distinction of anatomical structures. The signal-to-noise ratio (SNR), lesion contrast, contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC) were also measured. Comparisons of the quantitative and qualitative parameters between the two sequences were performed using the paired t-test and the Wilcoxon signed rank test. Results: The scores of overall image quality, lesion conspicuity, geometric distortion and distinction of anatomical structures of rs-EPI were all significantly higher than those of ss-EPI (all p < 0.05). The SNR and CNR were higher in rs-EPI than those in ss-EPI (all p < 0.05). There was no significant difference between ss-EPI and rs-EPI with regard to ROI size and mean ADCs of the tumour (p = 0.574 and p = 0.479, respectively), but the mean ADC of the normal tissue was higher in rs-EPI than in ss-EPI (1.73 ± 0.30 × 10{sup −3} mm{sup 2}/s vs. 1.60 ± 0.31 × 10{sup −3} mm{sup 2}/s, p = 0.001). Conclusions: DW imaging based on readout-segmented echo-planar imaging is a clinically useful technique to improve the image quality for the purpose of evaluating lesions in patients with rectal tumours.

  6. Reduced field-of -view diffusion-weighted magnetic resonance imaging of the pancreas: Comparison with conventional single-shot echo-planar imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyung Jin; Lee, Jeong Min; Yoon, Jeong Hee; Jang, Jin Young; Kim, Sun Whe; Ryu, Ji Kon; Han, Joon Koo; Choi, Byung Ihn [Seoul National University Hospital, Seoul (Korea, Republic of); Kannengiesser, Stephan [Siemens Healthcare, Erlangen (Germany)

    2015-12-15

    To investigate the image quality (IQ) and apparent diffusion coefficient (ADC) of reduced field-of-view (FOV) diffusion-weighted imaging (DWI) of pancreas in comparison with full FOV DWI. In this retrospective study, 2 readers independently performed qualitative analysis of full FOV DWI (FOV, 38 × 38 cm; b-value, 0 and 500 s/mm{sup 2}) and reduced FOV DWI (FOV, 28 × 8.5 cm; b-value, 0 and 400 s/mm{sup 2}). Both procedures were conducted with a two-dimensional spatially selective radiofrequency excitation pulse, in 102 patients with benign or malignant pancreatic diseases (mean size, 27.5 ± 14.4 mm). The study parameters included 1) anatomic structure visualization, 2) lesion conspicuity, 3) artifacts, 4) IQ score, and 5) subjective clinical utility for confirming or excluding initially considered differential diagnosis on conventional imaging. Another reader performed quantitative ADC measurements of focal pancreatic lesions and parenchyma. Wilcoxon signed-rank test was used to compare qualitative scores and ADCs between DWI sequences. Mann Whitney U-test was used to compare ADCs between the lesions and parenchyma. On qualitative analysis, reduced FOV DWI showed better anatomic structure visualization (2.76 ± 0.79 at b = 0 s/mm{sup 2} and 2.81 ± 0.64 at b = 400 s/mm{sup 2}), lesion conspicuity (3.11 ± 0.99 at b = 0 s/mm{sup 2} and 3.15 ± 0.79 at b = 400 s/mm{sup 2}), IQ score (8.51 ± 2.05 at b = 0 s/mm{sup 2} and 8.79 ± 1.60 at b = 400 s/mm{sup 2}), and higher clinical utility (3.41 ± 0.64), as compared to full FOV DWI (anatomic structure, 2.18 ± 0.59 at b = 0 s/mm{sup 2} and 2.56 ± 0.47 at b = 500 s/mm{sup 2}; lesion conspicuity, 2.55 ± 1.07 at b = 0 s/mm{sup 2} and 2.89 ± 0.86 at b = 500 s/mm{sup 2}; IQ score, 7.13 ± 1.83 at b = 0 s/mm{sup 2} and 8.17 ± 1.31 at b = 500 s/mm{sup 2}; clinical utility, 3.14 ± 0.70) (p < 0.05). Artifacts were significantly improved on reduced FOV DWI (2.65 ± 0.68) at b = 0 s/mm{sup 2} (full FOV DWI, 2.41 ± 0.63) (p

  7. Single-shot echo-planar MR sequences in the diagnosis of intracranial infectious diseases

    International Nuclear Information System (INIS)

    Tsuchiya, Kazuhiro; Katase, Shichiro; Yoshino, Ayako; Yamakami, Norio; Hachiya, Junichi

    1998-01-01

    The purpose of this study was to present our preliminary experience in the application of echo-planar-imaging (EPI) MR sequences for the diagnosis of intracranial infectious diseases and to assess the value of these sequences. We reviewed single-shot EPI MR images obtained at 1.5 T in 17 patients and compared these images with conventional or fast spin-echo (SE) or fluid attenuated inversion-recovery (FLAIR) images. The clinical diagnoses for the 17 patients were meningitis (2 patients), encephalitis or meningoencephalitis (7 patients), brain abscess (5 patients), epidural empyema (2 patients) and Creutzfeldt-Jakob disease (1 patient). We obtained EPI-T 2 -weighted (T 2 W) images in 8 patients, EPI-FLAIR images in 13 patients and EPI-diffusion-weighted (DW) images in 14 patients. Among the 8 patients for whom EPI-T 2 W imaging was performed, EPI-T 2 W imaging yielded superior results compared with SE-T 2 W imaging in 3 patients as a consequence of patient motion and equal results compared with SE-T 2 W imaging in 5 patients. Among the 13 patients for whom EPI-FLAIR imaging was performed, the EPI-FLAIR images were superior to conventional FLAIR images in 3 unstable patients. In the remaining 10 patients for whom EPI-FLAIR imaging was performed, EPI-FLAIR images were equivalent or inferior to conventional FLAIR images. In 6 patients with encephalitis or meningoencephalitis, the encephalitic lesions showed hyperintensity in EPI-DW images to a greater extent than in images obtained with the other techniques. In 3 patients, EPI-DW images also demonstrated hyperintensity for the contents of abscesses or areas of empyema that was not seen with the other imaging techniques. The value of EPI-T 2 W and EPI-FLAIR imaging is limited in uncooperative patients. EPI-DW imaging was found to be of value for the evaluation of several intracranial infectious diseases. (author)

  8. Single-shot echo-planar MR sequences in the diagnosis of intracranial infectious diseases

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiya, Kazuhiro; Katase, Shichiro; Yoshino, Ayako; Yamakami, Norio; Hachiya, Junichi [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine

    1998-06-01

    The purpose of this study was to present our preliminary experience in the application of echo-planar-imaging (EPI) MR sequences for the diagnosis of intracranial infectious diseases and to assess the value of these sequences. We reviewed single-shot EPI MR images obtained at 1.5 T in 17 patients and compared these images with conventional or fast spin-echo (SE) or fluid attenuated inversion-recovery (FLAIR) images. The clinical diagnoses for the 17 patients were meningitis (2 patients), encephalitis or meningoencephalitis (7 patients), brain abscess (5 patients), epidural empyema (2 patients) and Creutzfeldt-Jakob disease (1 patient). We obtained EPI-T{sub 2}-weighted (T{sub 2}W) images in 8 patients, EPI-FLAIR images in 13 patients and EPI-diffusion-weighted (DW) images in 14 patients. Among the 8 patients for whom EPI-T{sub 2}W imaging was performed, EPI-T{sub 2}W imaging yielded superior results compared with SE-T{sub 2}W imaging in 3 patients as a consequence of patient motion and equal results compared with SE-T{sub 2}W imaging in 5 patients. Among the 13 patients for whom EPI-FLAIR imaging was performed, the EPI-FLAIR images were superior to conventional FLAIR images in 3 unstable patients. In the remaining 10 patients for whom EPI-FLAIR imaging was performed, EPI-FLAIR images were equivalent or inferior to conventional FLAIR images. In 6 patients with encephalitis or meningoencephalitis, the encephalitic lesions showed hyperintensity in EPI-DW images to a greater extent than in images obtained with the other techniques. In 3 patients, EPI-DW images also demonstrated hyperintensity for the contents of abscesses or areas of empyema that was not seen with the other imaging techniques. The value of EPI-T{sub 2}W and EPI-FLAIR imaging is limited in uncooperative patients. EPI-DW imaging was found to be of value for the evaluation of several intracranial infectious diseases. (author)

  9. Single-Shot Echo-Planar Diffusion-Weighted MR Imaging at 3T and 1.5T for Differentiation of Benign Vertebral Fracture Edema and Tumor Infiltration

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hee Jin; Lee, So Yeon; Rho, Myung Ho; Chung, Eun Chul; Kim, Mi Sung; Kwon, Heon Ju; Youn, In Young [Department of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul 03181 (Korea, Republic of)

    2016-11-01

    To compare the apparent diffusion coefficient (ADC) value using single-shot echo-planar imaging sequences at 3T and 1.5T for differentiation of benign fracture edema and tumor infiltration of the vertebral body. A total of 46 spinal examinations were included in the 1.5T MRI group, and a total of 40 spinal examinations were included in the 3T MRI group. The ADC values of the lesion were measured and calculated. The diagnostic performance of the conventional MR image containing sagittal T2-weighted fat saturated image and each diffusion weighted image (DWI) with an ADC value with different b values were evaluated. The mean ADC value of the benign lesions was higher than that of the malignant lesions on 1.5T and 3T (p < 0.05). The sensitivity of the diagnostic performance was higher with an additional DWI in both 1.5T and 3T, but the sensitivities were similar with the addition of b values of 400 and 1000. The specificities of the diagnostic performances did not show significant differences (p value > 0.05). The diagnostic accuracies were higher when either of the DWIs (b values of 400 and 1000) was added to routine MR image for 1.5T and 3T. Statistical differences between 1.5T and 3T or between b values of 400 and 1000 were not seen. The ADC values of the benign lesions were significantly higher than those of the malignant lesions on 1.5T and 3T. There was no statistically significant difference in the diagnostic performances when either of the DWIs (b values of 400 and 1000) was added to the routine MR image for 1.5T and 3T.

  10. Can a single-shot black-blood T2-weighted spin-echo echo-planar imaging sequence with sensitivity encoding replace the respiratory-triggered turbo spin-echo sequence for the liver? An optimization and feasibility study.

    Science.gov (United States)

    Hussain, Shahid M; De Becker, Jan; Hop, Wim C J; Dwarkasing, Soendersing; Wielopolski, Piotr A

    2005-03-01

    To optimize and assess the feasibility of a single-shot black-blood T2-weighted spin-echo echo-planar imaging (SSBB-EPI) sequence for MRI of the liver using sensitivity encoding (SENSE), and compare the results with those obtained with a T2-weighted turbo spin-echo (TSE) sequence. Six volunteers and 16 patients were scanned at 1.5T (Philips Intera). In the volunteer study, we optimized the SSBB-EPI sequence by interactively changing the parameters (i.e., the resolution, echo time (TE), diffusion weighting with low b-values, and polarity of the phase-encoding gradient) with regard to distortion, suppression of the blood signal, and sensitivity to motion. The influence of each change was assessed. The optimized SSBB-EPI sequence was applied in patients (N = 16). A number of items, including the overall image quality (on a scale of 1-5), were used for graded evaluation. In addition, the signal-to-noise ratio (SNR) of the liver was calculated. Statistical analysis was carried out with the use of Wilcoxon's signed rank test for comparison of the SSBB-EPI and TSE sequences, with P = 0.05 considered the limit for significance. The SSBB-EPI sequence was improved by the following steps: 1) less frequency points than phase-encoding steps, 2) a b-factor of 20, and 3) a reversed polarity of the phase-encoding gradient. In patients, the mean overall image quality score for the optimized SSBB-EPI (3.5 (range: 1-4)) and TSE (3.6 (range: 3-4)), and the SNR of the liver on SSBB-EPI (mean +/- SD = 7.6 +/- 4.0) and TSE (8.9 +/- 4.6) were not significantly different (P > .05). Optimized SSBB-EPI with SENSE proved to be feasible in patients, and the overall image quality and SNR of the liver were comparable to those achieved with the standard respiratory-triggered T2-weighted TSE sequence. (c) 2005 Wiley-Liss, Inc.

  11. Initial experience in perfusion MR imaging of intracranial major artery occlusion with echo-planar technique

    International Nuclear Information System (INIS)

    Tsuchiya, Kazuhiro; Mizutani, Yoshiyuki; Inaoka, Sayuki; Hachiya, Junichi

    1997-01-01

    The purpose of this study was to evaluate the usefulness of perfusion MR imaging using a single-shot echo-planar technique in occlusion of intracranial main arteries. Our patient group consisted of 16 patients with internal carotid artery occlusion (n=9), Moyamoya disease (n=4), and middle cerebral artery occlusion (n=3). We performed the echo-planar perfusion studies with a 1.5-T unit using a free-induction-decay-type echo-planar sequence. With a bolus injection of Gd-DTPA, 30 consecutive scans were obtained at 10 sections every 2 seconds. The data were analyzed in three ways: a time-intensity curves in the territory of the involved artery (n=16); semiquantitative flow map of each section representing signal changes due to passage of Gd-DTPA (n=15); and serial images at a selected section (n=7). The time intensity curves were abnormal in 13 patients. The peak of signal drop was delayed in all of them. Flow maps showed focal flow abnormalities in 11 patients, but they were apparently normal in 4 patients probably due to collateral flow. In serial images, delay in appearance and/or disappearance of Gd-DTPA was noted in 6 patients. In patients with occlusion of intracranial main arteries, MR single-shot echo-planar technique is of clinical use because it can provide information about hemodynamic changes in a short examination time, in multiple sections, and with good temporal resolution. (author)

  12. Calculation of T2 relaxation time from ultrafast single shot sequences for differentiation of liver tumors. Comparison of echo-planar, HASTE, and spin-echo sequences

    International Nuclear Information System (INIS)

    Abe, Yasuko; Yamashita, Yasuyuki; Tang, Yi; Namimoto, Tomohiro; Takahashi, Mutsumasa

    2000-01-01

    The purpose of this study was to evaluate the accuracy of T2 calculation from single shot imaging sequences such as echo-planar imaging (EPI) and half-Fourier single shot turbo spin-echo (HASTE) imaging. For the phantom study, we prepared vials containing different concentrations of agarose, copper sulfate, and nickel chloride. The temperature of the phantom was kept at 22 deg C. MR images were obtained with a 1.5-Tesla superconductive magnet. Spin-echo (SE)-type EPI and HASTE sequences with different TEs were obtained for T2 calculation, and the T2 values were compared with those obtained from the Carr-Purcell-Meiborm-Gill (CPMG) sequence. The clinical study group consisted of 30 consecutive patients referred for MR imaging to characterize focal liver lesions. A total of 40 focal liver lesions were evaluated, including 25 primary or metastatic solid masses and 15 non-solid lesions. Single shot SE-type EPI and HASTE were both performed with TEs of 64 and 90 msec. In the phantom study, the T2 values obtained from both single shot sequences showed significant correlations with those from the CPMG sequence (T2 on EPI vs. T2 on CPMG: r=0.98, p<0.01; T2 on HASTE vs. T2 on CPMG: r=0.99, p<0.01). In the clinical study, mean T2 values for liver calculated from EPI (42 msec) were significantly shorter than those calculated from the HASTE sequence (58 msec) (p<0.001). Mean T2 values for solid tumors were 95 msec with HASTE and 72 msec with EPI, and mean T2 values for non-solid lesions were 128 msec with HASTE and 159 msec with EPI. Although mean T2 values between solid and non-solid lesions were significantly different for both EPI and HASTE sequences (p=0.01 for HASTE, p<0.001 for EPI), the overlap of solid and non-solid lesions was less frequent in EPI than in HASTE. With single shot sequences, it is possible to obtain the T2 values that show excellent correlation with the CPMG sequence. Although both HASTE and EPI are useful to calculate T2 values, EPI appears to be more

  13. Single-Shot MR Spectroscopic Imaging with Partial Parallel Imaging

    Science.gov (United States)

    Posse, Stefan; Otazo, Ricardo; Tsai, Shang-Yueh; Yoshimoto, Akio Ernesto; Lin, Fa-Hsuan

    2010-01-01

    An MR spectroscopic imaging (MRSI) pulse sequence based on Proton-Echo-Planar-Spectroscopic-Imaging (PEPSI) is introduced that measures 2-dimensional metabolite maps in a single excitation. Echo-planar spatial-spectral encoding was combined with interleaved phase encoding and parallel imaging using SENSE to reconstruct absorption mode spectra. The symmetrical k-space trajectory compensates phase errors due to convolution of spatial and spectral encoding. Single-shot MRSI at short TE was evaluated in phantoms and in vivo on a 3 T whole body scanner equipped with 12-channel array coil. Four-step interleaved phase encoding and 4-fold SENSE acceleration were used to encode a 16×16 spatial matrix with 390 Hz spectral width. Comparison with conventional PEPSI and PEPSI with 4-fold SENSE acceleration demonstrated comparable sensitivity per unit time when taking into account g-factor related noise increases and differences in sampling efficiency. LCModel fitting enabled quantification of Inositol, Choline, Creatine and NAA in vivo with concentration values in the ranges measured with conventional PEPSI and SENSE-accelerated PEPSI. Cramer-Rao lower bounds were comparable to those obtained with conventional SENSE-accelerated PEPSI at the same voxel size and measurement time. This single-shot MRSI method is therefore suitable for applications that require high temporal resolution to monitor temporal dynamics or to reduce sensitivity to tissue movement. PMID:19097245

  14. Echo Planar Diffusion-Weighted Imaging: Possibilities and Considerations with 12- and 32-Channel Head Coils

    Directory of Open Access Journals (Sweden)

    John N Morelli

    2012-01-01

    Full Text Available Interest in clinical brain magnetic resonance imaging using 32-channel head coils for signal reception continues to increase. The present investigation assesses possibilities for improving diffusion-weighted image quality using a 32-channel in comparison to a conventional 12-channel coil. The utility of single-shot (ss and an approach to readout-segmented (rs echo planar imaging (EPI are examined using both head coils. Substantial image quality improvements are found with rs-EPI. Imaging with a 32-channel head coil allows for implementation of greater parallel imaging acceleration factors or acquisition of scans at a higher resolution. Specifically, higher resolution imaging with rs-EPI can be achieved by increasing the number of readout segments without increasing echo-spacing or echo time to the degree necessary with ss-EPI - a factor resulting in increased susceptibility artifact and reduced signal-to-noise with the latter.

  15. Ultra-high-speed inversion recovery echo planar MR imaging

    International Nuclear Information System (INIS)

    Stehling, M.K.; Ordidge, R.J.; Coxon, R.; Chapman, B.; Houseman, A.M.; Guifoyle, D.; Blamire, A.; Gibbs, P.; Mansfield, P.

    1988-01-01

    Fast two-dimensional FT MR imaging techniques such as fast low-angle shot do not allow inversion recovery (IR). Rapid repetition of low-angle pulses is incompatible with a 180 0 inversion pulse. Echo planar imaging (EPI) can be applied in conjunction with IR, because after preparation of the spin system, a complete image is acquired. Data acquisition in less than 100 msec and real-time display allows interactive optimization of inversion time (4.0-9,000 msec) with little time penalty. The authors have applied IR EPI to the study of the brain, liver, and kidneys in normal volunteers and patients. Technical details are presented, and the applications of this first ultra-high-speed IR technique will be shown

  16. Multishot echo-planar MREIT for fast imaging of conductivity, current density, and electric field distributions.

    Science.gov (United States)

    Chauhan, Munish; Vidya Shankar, Rohini; Ashok Kumar, Neeta; Kodibagkar, Vikram D; Sadleir, Rosalind

    2018-01-01

    Magnetic resonance electrical impedance tomography (MREIT) sequences typically use conventional spin or gradient echo-based acquisition methods for reconstruction of conductivity and current density maps. Use of MREIT in functional and electroporation studies requires higher temporal resolution and faster sequences. Here, single and multishot echo planar imaging (EPI) based MREIT sequences were evaluated to see whether high-quality MREIT phase data could be obtained for rapid reconstruction of current density, conductivity, and electric fields. A gel phantom with an insulating inclusion was used as a test object. Ghost artifact, geometric distortion, and MREIT correction algorithms were applied to the data. The EPI-MREIT-derived phase-projected current density and conductivity images were compared with simulations and spin-echo images as a function of EPI shot number. Good agreement among measures in simulated, spin echo, and EPI data was achieved. Current density errors were stable and below 9% as the shot number decreased from 64 to 2, but increased for single-shot images. Conductivity reconstruction relative contrast ratios were stable as the shot number decreased. The derived electric fields also agreed with the simulated data. The EPI methods can be combined successfully with MREIT reconstruction algorithms to achieve fast imaging of current density, conductivity, and electric field. Magn Reson Med 79:71-82, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  17. Evaluation of cardiac function using multi-shot echo planar imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nakanishi, Tadashi; Tanitame, Nobuko; Hata, Ryoichiro; Hirai, Nobuhiko; Ikeda, Midori; Ono, Chiaki; Fukuoka, Haruhito; Ito, Katsuhide [Hiroshima Univ. (Japan). School of Medicine

    1998-01-01

    In this study, we performed multi-shot echo planar imaging (8 shot, TR/TE/FL=55 ms/18 ms/60 degrees) and k-space segmented fast gradient echo sequence (8 views per segment, TR/TE/FL=9.9 ms/1.8 ms/30 degrees) to assess cardiac function in healthy volunteers. Transaxial sections of the entire heart were obtained with both sequences in ECG triggered, breath hold, and with a 256 x 128 matrix. Resulting temporal resolution was 55 ms for echo planar imaging, and 71 ms for k-space segmented fast gradient echo sequence, respectively. Ventricular volume and ejection fraction of both ventricles and left ventricular mass obtained with multi-shot echo planar imaging were assessed in comparison with k-space segmented fast gradient echo sequence. Measurements of left ventricular volume, ejection fraction and mass obtained with multi-shot echo planar imaging demonstrated close correlation with those obtained with k-space segmented fast gradient echo sequence. Right ventricular volumes obtained with echo planar imaging were significantly higher than those obtained with k-space segmented fast gradient echo sequence. This tendency is considered to be due to differing contrast between right ventricular myocardium and fat tissue observed with echo planar imaging relative to that observed with fast gradient echo sequence, because fat suppression is always performed in echo planar images. Multi-shot echo planar imaging can be a reliable tool for measurement of cardiac functional parameters, although wall motion analysis of the left ventricle requires higher temporal resolution and a short axial section. (K.H.)

  18. Single-shot magnetic resonance spectroscopic imaging with partial parallel imaging.

    Science.gov (United States)

    Posse, Stefan; Otazo, Ricardo; Tsai, Shang-Yueh; Yoshimoto, Akio Ernesto; Lin, Fa-Hsuan

    2009-03-01

    A magnetic resonance spectroscopic imaging (MRSI) pulse sequence based on proton-echo-planar-spectroscopic-imaging (PEPSI) is introduced that measures two-dimensional metabolite maps in a single excitation. Echo-planar spatial-spectral encoding was combined with interleaved phase encoding and parallel imaging using SENSE to reconstruct absorption mode spectra. The symmetrical k-space trajectory compensates phase errors due to convolution of spatial and spectral encoding. Single-shot MRSI at short TE was evaluated in phantoms and in vivo on a 3-T whole-body scanner equipped with a 12-channel array coil. Four-step interleaved phase encoding and fourfold SENSE acceleration were used to encode a 16 x 16 spatial matrix with a 390-Hz spectral width. Comparison with conventional PEPSI and PEPSI with fourfold SENSE acceleration demonstrated comparable sensitivity per unit time when taking into account g-factor-related noise increases and differences in sampling efficiency. LCModel fitting enabled quantification of inositol, choline, creatine, and N-acetyl-aspartate (NAA) in vivo with concentration values in the ranges measured with conventional PEPSI and SENSE-accelerated PEPSI. Cramer-Rao lower bounds were comparable to those obtained with conventional SENSE-accelerated PEPSI at the same voxel size and measurement time. This single-shot MRSI method is therefore suitable for applications that require high temporal resolution to monitor temporal dynamics or to reduce sensitivity to tissue movement.

  19. Single-shot spiral imaging enabled by an expanded encoding model: Demonstration in diffusion MRI.

    Science.gov (United States)

    Wilm, Bertram J; Barmet, Christoph; Gross, Simon; Kasper, Lars; Vannesjo, S Johanna; Haeberlin, Max; Dietrich, Benjamin E; Brunner, David O; Schmid, Thomas; Pruessmann, Klaas P

    2017-01-01

    The purpose of this work was to improve the quality of single-shot spiral MRI and demonstrate its application for diffusion-weighted imaging. Image formation is based on an expanded encoding model that accounts for dynamic magnetic fields up to third order in space, nonuniform static B 0 , and coil sensitivity encoding. The encoding model is determined by B 0 mapping, sensitivity mapping, and concurrent field monitoring. Reconstruction is performed by iterative inversion of the expanded signal equations. Diffusion-tensor imaging with single-shot spiral readouts is performed in a phantom and in vivo, using a clinical 3T instrument. Image quality is assessed in terms of artefact levels, image congruence, and the influence of the different encoding factors. Using the full encoding model, diffusion-weighted single-shot spiral imaging of high quality is accomplished both in vitro and in vivo. Accounting for actual field dynamics, including higher orders, is found to be critical to suppress blurring, aliasing, and distortion. Enhanced image congruence permitted data fusion and diffusion tensor analysis without coregistration. Use of an expanded signal model largely overcomes the traditional vulnerability of spiral imaging with long readouts. It renders single-shot spirals competitive with echo-planar readouts and thus deploys shorter echo times and superior readout efficiency for diffusion imaging and further prospective applications. Magn Reson Med 77:83-91, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  20. Clinical evaluation of single-shot and readout-segmented diffusion-weighted imaging in stroke patients at 3 T

    International Nuclear Information System (INIS)

    Morelli, John; Porter, David; Ai, Fei

    2013-01-01

    Background: Diffusion-weighted imaging (DWI) magnetic resonance imaging (MRI) is most commonly performed utilizing a single-shot echo-planar imaging technique (ss-EPI). Susceptibility artifact and image blur are severe when this sequence is utilized at 3 T. Purpose: To evaluate a readout-segmented approach to DWI MR in comparison with single-shot echo planar imaging for brain MRI. Material and Methods: Eleven healthy volunteers and 14 patients with acute and early subacute infarctions underwent DWI MR examinations at 1.5 and 3T with ss-EPI and readout-segmented echo-planar (rs-EPI) DWI at equal nominal spatial resolutions. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) calculations were made, and two blinded readers ranked the scans in terms of high signal intensity bulk susceptibility artifact, spatial distortions, image blur, overall preference, and motion artifact. Results: SNR and CNR were greatest with rs-EPI (8.1 ± 0.2 SNR vs. 6.0 ± 0.2; P -4 at 3T). Spatial distortions were greater with single-shot (0.23 ± 0.03 at 3T; P <0.001) than with rs-EPI (0.12 ± 0.02 at 3T). Combined with blur and artifact reduction, this resulted in a qualitative preference for the readout-segmented scans overall. Conclusion: Substantial image quality improvements are possible with readout-segmented vs. single-shot EPI - the current clinical standard for DWI - regardless of field strength (1.5 or 3 T). This results in improved image quality secondary to greater real spatial resolution and reduced artifacts from susceptibility in MR imaging of the brain

  1. Anatomical details of the brainstem and cranial nerves visualized by high resolution readout-segmented multi-shot echo-planar diffusion-weighted images using unidirectional MPG at 3T

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Yamazaki, Masahiro; Kawai, Hisashi; Sone, Michihiko; Nakashima, Tsutomu; Isoda, Haruo

    2011-01-01

    We compared diffusion-weighted imaging (DWI) with readout-segmented multi-shot echo-planar imaging (rs-EPI) and single-shot EPI, both using unidirectional motion-probing gradient, in 10 patients for visualization of the anatomical structures in the brainstem. DWI by rs-EPI was significantly better than DWI by single-shot EPI for visualizing the medial longitudinal fasciculus, lateral lemniscus, corticospinal tract, and seventh/eighth cranial nerves and offered significantly less distortion of the brainstem. (author)

  2. Automatic cortical surface reconstruction of high-resolution T1 echo planar imaging data

    OpenAIRE

    Renvall, Ville; Witzel, Thomas; Wald, Lawrence L.; Polimeni, Jonathan R.

    2016-01-01

    Echo planar imaging (EPI) is the method of choice for the majority of functional magnetic resonance imaging (fMRI), yet EPI is prone to geometric distortions and thus misaligns with conventional anatomical reference data. The poor geometric correspondence between functional and anatomical data can lead to severe misplacements and corruption of detected activation patterns. However, recent advances in imaging technology have provided EPI data with increasing quality and resolution. Here we pre...

  3. Study of turbulent flow using Half-Fourier Echo-Planar imaging

    International Nuclear Information System (INIS)

    Rodriguez, A.O.

    2006-01-01

    The Echo-Planar Imaging technique combined with a partial Fourier acquisition method was used to obtain velocity images for liquid flows in a circular cross-section pipe at Reynolds number of up to 8000. This partial-Fourier imaging scheme is able to generate shorter echo times than the full-Fourier Echo-Planar Imaging methods, reducing the signal attenuation due to T2 * and flow. Velocity images along the z axis were acquired with a time-scale of 80 ms thus obtaining a real-time description of flow in both the laminar and turbulent regimes. Velocity values and velocity fluctuations were computed with the flow image data. A comparison plot of NMR velocity and bulk velocity and a plot of velocity fluctuations were calculated to investigate the feasibility of this imaging technique. Flow encoded Echo-Planar Imaging together with a reduced data acquisition method can provide us with a real-time technique to capture instantaneous images of the flow field for both laminar and turbulent regimes. (author)

  4. Comparison of Fourier transform and continuous wavelet transform to study echo-planar imaging flow maps

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez G, A.; Bowtell, R.; Mansfield, P. [Area de Procesamiento Digital de Senales e Imagenes Biomedicas. Universidad Autonoma Metropolitana Iztapalapa. Mexico D.F. 09340 Mexico (Mexico)

    1998-12-31

    Velocity maps were studied combining Doyle and Mansfield method (1986) with each of the following transforms: Fourier, window Fourier and wavelet (Mexican hat). Continuous wavelet transform was compared against the two Fourier transform to determine which technique is best suited to study blood maps generated by Half Fourier Echo-Planar Imaging. Coefficient images were calculated and plots of the pixel intensity variation are presented. Finally, contour maps are shown to visualize the behavior of the blood flow in the cardiac chambers for the wavelet technique. (Author)

  5. Comparison of Fourier transform and continuous wavelet transform to study echo-planar imaging flow maps

    International Nuclear Information System (INIS)

    Rodriguez G, A.; Bowtell, R.; Mansfield, P.

    1998-01-01

    Velocity maps were studied combining Doyle and Mansfield method (1986) with each of the following transforms: Fourier, window Fourier and wavelet (Mexican hat). Continuous wavelet transform was compared against the two Fourier transform to determine which technique is best suited to study blood maps generated by Half Fourier Echo-Planar Imaging. Coefficient images were calculated and plots of the pixel intensity variation are presented. Finally, contour maps are shown to visualize the behavior of the blood flow in the cardiac chambers for the wavelet technique. (Author)

  6. Efficacy of dynamic susceptibility contrast MRI using echo-planar imaging in differential diagnosis of breast tumors

    International Nuclear Information System (INIS)

    Yoshino, Ayako

    1998-01-01

    It has been shown that T1-weighted dynamic MR imaging is a useful method in differentiating malignant breast tumors from benign lesions. Invasive breast carcinomas enhance more rapidly than benign lesions such as fibroadenomas, papillomas, and proliferative fibrocystic diseases. However, significant overlap in the dynamic profile of benign and malignant lesions may occur, resulting in relatively low specificity, which is an inherent limitation of this technique. The author attempted to improve diagnostic accuracy by utilizing dynamic susceptibility contrast MR imaging (DSC-MRI) with a single-shot echo-planar imaging sequence. Twenty-two patients underwent DSC-MRI using a 1.5-T unit (Magnetom Vision, Siemens). Images were obtained before, during and after the bolus injection of 20 mL of gadopentetate dimeglumine. The signal reduction rate within the first 30 seconds (ΔRT2) was calculated by the following equation: ΔRT2 = (postcontrast signal intensity-precontrast signal intensity) /precontrast signal intensity. A rapid, strong decrease in signal intensity was observed on the first pass of the contrast material in all cases of carcinoma, whereas no or only a minimal decrease in signal intensity was observed in all but one of the benign lesions. This method seems to be more accurate than T1-weighted dynamic MR imaging in the differentiation benign and malignant breast lesions. Since DSC-MRI can be performed quickly, subsequent conventional T1-weighted imaging can provide additional information about the morphologic features of lesions, to further support the diagnosis. In conclusion, DSC-MRI seems to be a promising method for the accurate preoperative assessment of breast lesions. (author)

  7. Efficacy of dynamic susceptibility contrast MRI using echo-planar imaging in differential diagnosis of breast tumors

    Energy Technology Data Exchange (ETDEWEB)

    Yoshino, Ayako [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine

    1998-07-01

    It has been shown that T1-weighted dynamic MR imaging is a useful method in differentiating malignant breast tumors from benign lesions. Invasive breast carcinomas enhance more rapidly than benign lesions such as fibroadenomas, papillomas, and proliferative fibrocystic diseases. However, significant overlap in the dynamic profile of benign and malignant lesions may occur, resulting in relatively low specificity, which is an inherent limitation of this technique. The author attempted to improve diagnostic accuracy by utilizing dynamic susceptibility contrast MR imaging (DSC-MRI) with a single-shot echo-planar imaging sequence. Twenty-two patients underwent DSC-MRI using a 1.5-T unit (Magnetom Vision, Siemens). Images were obtained before, during and after the bolus injection of 20 mL of gadopentetate dimeglumine. The signal reduction rate within the first 30 seconds ({Delta}RT2) was calculated by the following equation: {Delta}RT2 (postcontrast signal intensity-precontrast signal intensity) /precontrast signal intensity. A rapid, strong decrease in signal intensity was observed on the first pass of the contrast material in all cases of carcinoma, whereas no or only a minimal decrease in signal intensity was observed in all but one of the benign lesions. This method seems to be more accurate than T1-weighted dynamic MR imaging in the differentiation benign and malignant breast lesions. Since DSC-MRI can be performed quickly, subsequent conventional T1-weighted imaging can provide additional information about the morphologic features of lesions, to further support the diagnosis. In conclusion, DSC-MRI seems to be a promising method for the accurate preoperative assessment of breast lesions. (author)

  8. The clinical potential of ultra-high-speed echo-planar imaging

    International Nuclear Information System (INIS)

    Worthington, B.S.; Firth, J.L.; Morris, G.K.; Johnson, I.R.; Coxon, R.; Blamire, A.M.; Gibbs, P.; Mansfield, P.

    1990-01-01

    Ultra-high-speed echo-planar imaging (EPI) allows acquisition of a complete two-dimensional image in 64 to 128 ms devoid of movement artefact and without sacrifice of contrast due to relaxation time effects. In conventional whole-body MRI, however, obtrusive movement artefact and extended imaging time, resulting from the need to apply multiple sequences to facilitate lesion detection and pathological characterization, remain limitations. Reduced total examination time increases patient tolerance and throughput; furthermore optimization of contrast to achieve maximal conspicuity of particular features in liver or brain pathology is achieved simply and interactively by real time adjustment of the imaging parameters. The method provides the opportunity to study in real time dynamic events such as flow phenomena in the vascular and cerebrospinal fluid compartments of the brain as well as the kinetics of administered contrast agents. EPI is the only means of capturing the irregular motion of aperiodic cardiac events and bowel peristalsis. (author)

  9. Functional imaging of submandibular glands: diffusion-weighted echo-planar MRI before and after stimulation

    International Nuclear Information System (INIS)

    Arndt, C.; Cramer, M.C.; Weiss, F.; Kaul, M.G.; Adam, G.; Habermann, C.R.; Graessner, J.; Petersen, K.; Reitmeier, F.; Jaehne, M.

    2006-01-01

    Purpose: To investigate the feasibility of diffusion-weighted (DWI) echo-planar imaging (EPI) to depict the submandibular glands and to measure different functional conditions. Materials and Methods: Twenty-seven healthy volunteers were examined. Diffusion weighted sequence was performed prior to stimulation. Exactly 30 seconds after a commercially available lemon juice was given orally, the diffusion weighted sequence was repeated. All examinations were performed by using a 1.5-T superconducting system with a 30 mT/m maximum gradient capability and maximum slew rate of 125 mT/m/sec (Magnetom Symphony, Siemens, Erlangen, Germany). The lower part of the circularly polarized (CP) head coil and a standard two-element CP neck array coil were used. The flexibility of the neck array coil allowed positioning the N1 element (upper part of the coil) right next to the submandibular gland. The axial diffusion-weighted EPI (echo planar imaging) sequence was performed using a matrix of 119 x 128, a field of view of 250 x 250 mm (pixel size 2.1 x 1.95 mm), a section thickness of 5 mm with an interslice gap of 1 mm. The b factors used were 0 sec/mm 2 , 500 sec/mm 2 and 1000 sec/mm 2 . Apparent diffusion coefficient (ADC) maps were digitally transferred to MRIcro (Chris Rorden, University of Nottingham, Great Britain). After detecting the submandibular glands a region of interest (ROI) was placed manually exactly within the boarder of both submandibular glands, excluding the external carotid artery on ADC maps. These procedures were performed on all ADC slices the submandibular glands could be differentiated in before and after oral stimulation. For statistical comparison of results, a student's t-test was performed with an overall two-tailed significance level of p=0.05. Results: The visualization of the submandibular glands using the diffusion-weighted EPI sequence was possible in all of the 27 volunteers. Prior to oral stimulation an ADC of 1.31 x 10 -3 mm 2 /sec (95% CI, 1

  10. Functional imaging of parotid glands: Diffusion-weighted echo-planar MRI before and after stimulation

    Energy Technology Data Exchange (ETDEWEB)

    Habermann, C.R.; Cramer, M.C.; Gossrau, P.; Adam, G. [University Hospital Hamburg-Eppendorf (Germany). Department of Diagnostic and Interventional Radiology; Graessner, J. [Siemens AG, Hamburg (Germany). Medical Solutions; Reitmeier, F.; Jaehne, M. [University Hospital Hamburg-Eppendorf (Germany). Department of Oto-, Rhino-, Laryngology; Fiehler, J. [University Hospital Hamburg-Eppendorf (Germany). Department of Neuroradiology; Schoder, V. [University Hospital Hamburg-Eppendorf (Germany). Institute for Medical Biometry and Epidemiology

    2004-10-01

    Purpose: To investigate the feasibility of diffusion-weighted (DW) echo-planar imaging (EPI) for measuring different functional conditions of the parotid gland and to compare different measurement approaches. Materials and Methods: Parotid glands of 27 healthy volunteers were examined with a DW EPI sequence (TR 1,500 msec, TE 77 msec, field-of-view 250 x 250 mm, pixel size 2.10 x 1.95 mm, section thickness 5 mm) before and after oral stimulation with commercially available lemon juice. The b factors used were 0, 500, and 1,000 sec/mm{sup 2}. Apparent diffusion coefficient (ADC) maps were digitally transferred to MRIcro (Chris Rorden, University of Nottingham, Great Britain) and evaluated with a manually placed circular region of interest (ROI) containing 100-200 pixel. Additional ROIs including the entire parotid gland were placed on either side. The results of both measurements were compared, using the Student's t test based on the median ADC values for each person. A two-tailed p-value of less than.05 was determined to indicate statistical significance. To compare both measurement approaches, the Pearson's correlation coefficient (r) was calculated. Results: Diffusion-weighted echo-planar MR imaging successfully visualized the parotid gland of all volunteers. In a first step, the median ADC value per person was computed. Using ROIs of 100-200 pixels, the mean was calculated to be 1.08 x 10{sup -3} mm{sup 2}/sec{+-}0.12 x 10{sup -3} mm{sup 2}/sec for both parotid glands prior to simulation. After stimulation, the mean ADC was measured at 1.15 x 10{sup -3} mm{sup 2}/sec{+-}0.11 x 10{sup -3} mm{sup 2}/sec for both parotid glands. Evaluating the entire parotid gland, the ADC was 1.12 x 10{sup -3} mm{sup 2}/sec{+-}0.08 x 10{sup -3} mm{sup 2}/sec prior to simulation, whereas the ADC increased to 1.18 x 10{sup -3} mm{sup 2}/sec{+-}0.09 x 10{sup -3} mm{sup 2}/sec after simulation with lemon juice. For both types of measurements, the increase in ADC after

  11. Sensitivity-encoded (SENSE) proton echo-planar spectroscopic imaging (PEPSI) in the human brain.

    Science.gov (United States)

    Lin, Fa-Hsuan; Tsai, Shang-Yueh; Otazo, Ricardo; Caprihan, Arvind; Wald, Lawrence L; Belliveau, John W; Posse, Stefan

    2007-02-01

    Magnetic resonance spectroscopic imaging (MRSI) provides spatially resolved metabolite information that is invaluable for both neuroscience studies and clinical applications. However, lengthy data acquisition times, which are a result of time-consuming phase encoding, represent a major challenge for MRSI. Fast MRSI pulse sequences that use echo-planar readout gradients, such as proton echo-planar spectroscopic imaging (PEPSI), are capable of fast spectral-spatial encoding and thus enable acceleration of image acquisition times. Combining PEPSI with recent advances in parallel MRI utilizing RF coil arrays can further accelerate MRSI data acquisition. Here we investigate the feasibility of ultrafast spectroscopic imaging at high field (3T and 4T) by combining PEPSI with sensitivity-encoded (SENSE) MRI using eight-channel head coil arrays. We show that the acquisition of single-average SENSE-PEPSI data at a short TE (15 ms) can be accelerated to 32 s or less, depending on the field strength, to obtain metabolic images of choline (Cho), creatine (Cre), N-acetyl-aspartate (NAA), and J-coupled metabolites (e.g., glutamate (Glu) and inositol (Ino)) with acceptable spectral quality and localization. The experimentally measured reductions in signal-to-noise ratio (SNR) and Cramer-Rao lower bounds (CRLBs) of metabolite resonances were well explained by both the g-factor and reduced measurement times. Thus, this technology is a promising means of reducing the scan times of 3D acquisitions and time-resolved 2D measurements. Copyright (c) 2007 Wiley-Liss, Inc.

  12. Single-shot spiral imaging at 7 T.

    Science.gov (United States)

    Engel, Maria; Kasper, Lars; Barmet, Christoph; Schmid, Thomas; Vionnet, Laetitia; Wilm, Bertram; Pruessmann, Klaas P

    2018-03-25

    The purpose of this work is to explore the feasibility and performance of single-shot spiral MRI at 7 T, using an expanded signal model for reconstruction. Gradient-echo brain imaging is performed on a 7 T system using high-resolution single-shot spiral readouts and half-shot spirals that perform dual-image acquisition after a single excitation. Image reconstruction is based on an expanded signal model including the encoding effects of coil sensitivity, static off-resonance, and magnetic field dynamics. The latter are recorded concurrently with image acquisition, using NMR field probes. The resulting image resolution is assessed by point spread function analysis. Single-shot spiral imaging is achieved at a nominal resolution of 0.8 mm, using spiral-out readouts of 53-ms duration. High depiction fidelity is achieved without conspicuous blurring or distortion. Effective resolutions are assessed as 0.8, 0.94, and 0.98 mm in CSF, gray matter and white matter, respectively. High image quality is also achieved with half-shot acquisition yielding image pairs at 1.5-mm resolution. Use of an expanded signal model enables single-shot spiral imaging at 7 T with unprecedented image quality. Single-shot and half-shot spiral readouts deploy the sensitivity benefit of high field for rapid high-resolution imaging, particularly for functional MRI and arterial spin labeling. © 2018 International Society for Magnetic Resonance in Medicine.

  13. Anatomical constraints on visualization of the human hippocampus using echo-planar imaging

    International Nuclear Information System (INIS)

    Asano, Shuichiro; Kirino, Takaaki; Mihara, Ban; Sugishita, Morihiro

    2004-01-01

    Reliable visualization of the hippocampus on echo-planar imaging (EPI) is essential in analyzing memory function using functional magnetic resonance imaging. However, the hippocampal area is notoriously prone to susceptibility artifacts caused by structures at the skull base, and avoiding such artifacts by appropriately selecting the subjects for a study is of practical importance. To elucidate factors affecting the extent of the artifacts we obtained EPI in a total of 62 hippocampi from 31 healthy volunteers and evaluated various anatomical measurements possibly associated with the quality of the images. The hippocampal head was sufficiently well demonstrated on 40 of 62 images (65%), and there were two parameters that significantly differed between the good (n=40) and poor (n=22) imaging studies: The vertical diameter (DV) of the opening of the internal acoustic meatus (IAM) and the pneumatization rate of the sphenoid sinus (RP-SS). From logistic regression analysis with the stepwise method, in addition to these two factors, the distance between the hippocampal body and IAM (Dhippo-IAM) and the distance between the hippocampal head and the middle cranial fossa at the skull base (Dhippo-base) were extracted. DV-IAM, RP-SS, and Dhippo-base were negatively correlated with the good imaging of the hippocampal head. On the other hand, Dhippo-IAM was positively correlated. These easily measurable parameters will be helpful in selecting subjects and in increasing the efficiency of hippocampal visualization in studies on human memory function. (orig.)

  14. Study of internal structure of the human fetus in utero by echo-planar magnetic resonance imaging.

    Science.gov (United States)

    Johnson, I R; Stehling, M K; Blamire, A M; Coxon, R J; Howseman, A M; Chapman, B; Ordidge, R J; Mansfield, P; Symonds, E M; Worthington, B S

    1990-08-01

    The ultrafast echo-planar magnetic resonance imaging technology, developed and built in Nottingham, has been used to produce the first snapshot images of the human fetus in utero. The imager, operating at a proton resonance frequency of 22 MHz, produces transaxial views in 64 or 128 milliseconds. These images comprise either 64 x 128 or 128 x 128 pixels with an in-plane resolution of 3 x 3 mm2. The slice thickness is 10 mm. Fetal scans of up to 32 contiguous slices are produced in a few minutes. These have been used to study the internal structure of the uterus and the fetus in a range of cases with gestations ranging from 26 weeks to term. Echo-planar imaging seems particularly suitable as an imaging modality since its high speed obviates image blurring arising from fetal motion.

  15. Echo-planar MR imaging of dissolved hyperpolarized 129Xe. Potential for M angiography

    International Nuclear Information System (INIS)

    Maansson, S.

    2002-01-01

    Purpose: The feasibility of hyperpolarized 129 Xe for fast MR angiography (MRA) was evaluated using the echo-planar imaging (EPI) technique. Material and Methods: Hyperpolarized Xe gas was dissolved in ethanol; a carrier agent with high solubility for Xe (Ostwald solubility coefficient 2.5) and long relaxation times. The dissolved Xe was injected as a bolus into a flow phantom where the mean flow velocity was 15 cm/s. Ultrafast EPI images with 44 ms scan time were acquired of the flowing bolus and the signal-to-noise ratios (SNR) were measured. Results: The relaxation times of hyperpolarized Xe in ethanol were measured to T1=160±11 s and T2 ≅ 20 s. The resulting images of the flowing liquid were of reasonable quality and had an SNR of about 70. Conclusion: Based on the SNR of the obtained Xe EPI images; it was estimated that rapid in vivo MRA with 129 Xe may be feasible; provided that an efficient; biologically acceptable carrier for Xe can be found and polarization levels of more than 25% can be achieved in isotopically enriched 129 Xe

  16. Does non-echo-planar diffusion-weighted magnetic resonance imaging have a role in assisting the clinical diagnosis of cholesteatoma in selected cases?

    Science.gov (United States)

    Nash, R; Lingam, R K; Chandrasekharan, D; Singh, A

    2018-03-01

    To determine the diagnostic performance of diffusion-weighted magnetic resonance imaging in the assessment of patients with suspected, but not clinically evident, cholesteatoma. A retrospective analysis of a prospectively collected database of non-echo-planar diffusion-weighted magnetic resonance imaging studies (using a half-Fourier single-shot turbo-spin echo sequence) was conducted. Clinical records were retrospectively reviewed to determine indications for imaging and operative findings. Seventy-eight investigations in 74 patients with suspected cholesteatoma aged 5.7-79.2 years (mean, 41.7 years) were identified. Operative confirmation was available in 44 ears. Diagnostic accuracy of the imaging technique was calculated using operative findings as a 'gold standard'. Sensitivity of the investigation was examined via comparison with clinically evident cholesteatoma. The accuracy of diffusion-weighted magnetic resonance imaging in assessment of suspected cholesteatoma was 63.6 per cent. The imaging technique was significantly less accurate in assessment of suspected cholesteatoma than clinically evident disease (p < 0.001). Computed tomography and diffusion-weighted magnetic resonance imaging may be complementary in assessment of suspected cholesteatoma, but should be used with caution, and clinical judgement is paramount.

  17. The clinical utility of reduced-distortion readout-segmented echo-planar imaging in the head and neck region: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Koyasu, Sho; Iima, Mami; Umeoka, Shigeaki; Morisawa, Nobuko; Togashi, Kaori [Kyoto University, Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Sakyo-Ku, Kyoto (Japan); Porter, David A. [Siemens AG, MED MR PLM AW Neurology, Allee am Roethelheimpark 2, Erlangen (Germany); Ito, Juichi [Kyoto University, Department of Otolaryngology, Head and Neck Surgery, Graduate School of Medicine, Sakyo-Ku, Kyoto (Japan); Le Bihan, Denis [Kyoto University, Human Brain Research Center, Graduate School of Medicine, Sakyo-Ku, Kyoto (Japan); Neurospin, CEA-Saclay Center, Gif-sur-Yvette Cedex (France)

    2014-12-15

    To evaluate whether readout-segmented echo-planar imaging (RS-EPI) diffusion weighted image (DWI) can diminish image distortion in the head and neck area, compared with single-shot (SS)-EPI DWI. We conducted phantom and patient studies using 3 T magnetic resonance imaging (MRI) with a 16-channel coil. For the phantom study, we evaluated distortion and signal homogeneity in gel phantoms. For the patient study, 29 consecutive patients with clinically suspicious parotid lesions were prospectively enrolled. RS-EPI and SS-EPI DWI were evaluated by two independent readers for identification of organ/lesion and distortion, using semiquantitative scales and quantitative scores. Apparent diffusion coefficient (ADC) values and contrast-noise ratios of parotid tumours (if present; n = 15) were also compared. The phantom experiments showed that RS-EPI provided less distorted and more homogeneous ADC maps than SS-EPI. In the patient study, RS-EPI was found to provide significantly less distortion in almost all organs/lesions (p < 0.05), according to both semiquantitative scales and quantitative scores. There was no significant difference in ADC values and contrast-noise ratios between the two DWI techniques. The distortion in DWI was significantly reduced with RS-EPI in both phantom and patient studies. The RS-EPI technique provided more homogenous images than SS-EPI, and can potentially offer higher image quality in the head and neck area. (orig.)

  18. Echo planar perfusion imaging with high spatial and temporal resolution: methodology and clinical aspects

    International Nuclear Information System (INIS)

    Bitzer, M.; Klose, U.; Naegele, T.; Friese, S.; Kuntz, R.; Voigt, K.; Fetter, M.; Opitz, H.

    1999-01-01

    The purpose of the present study was to analyse specific advantages of calculated parameter images and their limitations using an optimized echo-planar imaging (EPI) technique with high spatial and temporal resolution. Dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) was performed in 12 patients with cerebrovascular disease and in 13 patients with brain tumours. For MR imaging of cerebral perfusion an EPI sequence was developed which provides a temporal resolution of 0.68 s for three slices with a 128 x 128 image matrix. To evaluate DSC-MRI, the following parameter images were calculated pixelwise: (1) Maximum signal reduction (MSR); (2) maximum signal difference (ΔSR); (3) time-to-peak (T p ); and (4) integral of signal-intensity-time curve until T p (S Int ). The MSR maps were superior in the detection of acute infarctions and ΔSR maps in the delineation of vasogenic brain oedema. The time-to-peak (T p ) maps seemed to be highly sensitive in the detection of poststenotic malperfused brain areas (sensitivity 90 %). Hyperperfused areas of brain tumours were detectable down to a diameter of 1 cm with high sensitivity (> 90 %). Distinct clinical and neuroradiological conditions revealed different suitabilities for the parameter images. The time-to-peak (T p ) maps may be an important advantage in the detection of poststenotic ''areas at risk'', due to an improved temporal resolution using an EPI technique. With regard to spatial resolution, a matrix size of 128 x 128 is sufficient for all clinical conditions. According to our results, a further increase in matrix size would not improve the spatial resolution in DSC-MRI, since the degree of the vascularization of lesions and the susceptibility effect itself seem to be the limiting factors. (orig.)

  19. Automatic cortical surface reconstruction of high-resolution T1 echo planar imaging data.

    Science.gov (United States)

    Renvall, Ville; Witzel, Thomas; Wald, Lawrence L; Polimeni, Jonathan R

    2016-07-01

    Echo planar imaging (EPI) is the method of choice for the majority of functional magnetic resonance imaging (fMRI), yet EPI is prone to geometric distortions and thus misaligns with conventional anatomical reference data. The poor geometric correspondence between functional and anatomical data can lead to severe misplacements and corruption of detected activation patterns. However, recent advances in imaging technology have provided EPI data with increasing quality and resolution. Here we present a framework for deriving cortical surface reconstructions directly from high-resolution EPI-based reference images that provide anatomical models exactly geometric distortion-matched to the functional data. Anatomical EPI data with 1mm isotropic voxel size were acquired using a fast multiple inversion recovery time EPI sequence (MI-EPI) at 7T, from which quantitative T1 maps were calculated. Using these T1 maps, volumetric data mimicking the tissue contrast of standard anatomical data were synthesized using the Bloch equations, and these T1-weighted data were automatically processed using FreeSurfer. The spatial alignment between T2(⁎)-weighted EPI data and the synthetic T1-weighted anatomical MI-EPI-based images was improved compared to the conventional anatomical reference. In particular, the alignment near the regions vulnerable to distortion due to magnetic susceptibility differences was improved, and sampling of the adjacent tissue classes outside of the cortex was reduced when using cortical surface reconstructions derived directly from the MI-EPI reference. The MI-EPI method therefore produces high-quality anatomical data that can be automatically segmented with standard software, providing cortical surface reconstructions that are geometrically matched to the BOLD fMRI data. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Clinical evaluation of multishot echo planar imaging after administration of superparamagnetic iron oxide for hepatic tumors

    International Nuclear Information System (INIS)

    Sugai, Yukio; Watanabe, Yorihisa; Ito, Kazushi; Hosoya, Takaaki; Yamaguchi, Koichi

    1998-01-01

    Ten cases of hepatocellular carcinoma and three cases of metastatic liver tumor were evaluated using breath-hold multishot echo planar imaging (EPI) before and after administration of super-paramagnetic iron oxide (SPIO), and the results were compared to those with breath-hold fast multi-planar SPGR (T 1 WI) and fat-suppressed respiratory-triggered FSE (T 2 WI). Qualitative imaging evaluation of lesion detectability showed that T 2 WI was much more useful than T 1 WI as previously reported, and more useful than EPI. Quantitative evaluation showed that the signal to noise (S/N) ratios of the liver parenchyma decreased after administration of SPIO and the changes were significant on all pulse sequences. The change ratio of the S/N ratio of the liver parenchyma after administration of SPIO on EPI was significantly higher than on T 1 WI and T 2 WI. The tumor-liver contrast to noise (C/N) ratios increased after administration of SPIO and the changes were significant on T 1 WI and T 2 WI, but not on EPI. These results suggested that the tumor S/N ratio decreased after administration of SPIO on EPI. The tumor diameters on EPI were significantly reduced after administration of SPIO. Magnetization and flow artifacts on EPI were detected in all cases and caused distortion: the signal decreased in the liver parenchyma. We concluded that EPI after administration of SPIO is not currently useful compared to other pulse sequences and cannot yet replace T 2 WI. (author)

  1. Clinical evaluation of echo-planar diffusion-weighted imaging (EPI-DWI) for diagnosis of breast cancer

    International Nuclear Information System (INIS)

    Nakajima, Mika; Nitatori, Toshiaki; Matsuda, Minoru; Fukushima, Hisaki; Ihara, Kuniko; Seki, Tsuneaki

    2008-01-01

    The purpose of this study was to compare echo-planar diffusion-weighted imaging (EPI-DWI) with dynamic contrast-enhanced magnetic resonance imaging (MRI) in terms of the rate of detection, extension, and quality of diagnosis of breast cancer in order to estimate the usefulness of EPI-DWI. One hundred and three cases of 101 patients who underwent MRI prior to surgery for breast cancer were evaluated. (papillotubular carcinoma 22; solid-tubular carcinoma 20; scirrhous carcinoma 45; mucinous carcinoma 2; medullary carcinoma 1; invasive lobular carcinoma 2; apocrine carcinoma 2; ductal carcinoma in situ (DCIS) and microinvasive ductal carcinoma 9). Twelve cases of benign lesion were also evaluated. Single-shot EPI-DWI was performed before routine dynamic MRI and images of cancer detection and cancer extension both were compared with the pathological findings. The apparent diffusion coefficient (ADC) values of the lesions were measured and compared to the ADC values of benign lesions and normal breast tissues. The differences between the ADC values for the various histopathological types and the time-intensity curve (TIC) patterns of the dynamic MRI were also estimated. The EPI-DWI demonstrated abnormal high-intensity areas corresponding to the breast cancer lesions; these areas demonstrated good correlation with the enhanced areas observed in the early phase of dynamic MRI and cancer extension in the pathological findings. Frequently, normal breast tissues manifested as high-intensity areas in EPI-DWI; however, it was possible to distinguish between normal breast tissues and breast lesions by correlating these images with T2- weighted images and corresponding ADC values. The threshold value between malignant and benign lesions that resulted both high sensitivity and specificity was about 1.5 x 10 -3 x mm 2 /second. Mucinous carcinoma and DCIS/ microinvasive carcinoma exhibited higher ADC values than those observed in the other histopathological types, however, no

  2. Reconstruction strategy for echo planar spectroscopy and its application to partially undersampled imaging

    DEFF Research Database (Denmark)

    Hanson, L G; Schaumburg, K; Paulson, O B

    2000-01-01

    The most commonly encountered form of echo planar spectroscopy involves oscillating gradients in one spatial dimension during readout. Data are consequently not sampled on a Cartesian grid. A fast gridding algorithm applicable to this particular situation is presented. The method is optimal, i.......e., it performs as well as the full discrete Fourier transform for band limited signals while allowing for use of the fast Fourier transform. The method is demonstrated for reconstruction of data that are partially undersampled in the time domain. The advantages of undersampling are lower hardware requirements...

  3. Fast susceptibility-weighted imaging with three-dimensional short-axis propeller (SAP)-echo-planar imaging.

    Science.gov (United States)

    Holdsworth, Samantha J; Yeom, Kristen W; Moseley, Michael E; Skare, S

    2015-05-01

    Susceptibility-weighted imaging (SWI) in neuroimaging can be challenging due to long scan times of three-dimensional (3D) gradient recalled echo (GRE), while faster techniques such as 3D interleaved echo-planar imaging (iEPI) are prone to motion artifacts. Here we outline and implement a 3D short-axis propeller echo-planar imaging (SAP-EPI) trajectory as a faster, motion-correctable approach for SWI. Experiments were conducted on a 3T MRI system. The 3D SAP-EPI, 3D iEPI, and 3D GRE SWI scans were acquired on two volunteers. Controlled motion experiments were conducted to test the motion-correction capability of 3D SAP-EPI. The 3D SAP-EPI SWI data were acquired on two pediatric patients as a potential alternative to 2D GRE used clinically. The 3D GRE images had a better target resolution (0.47 × 0.94 × 2 mm, scan time = 5 min), iEPI and SAP-EPI images (resolution = 0.94 × 0.94 × 2 mm) were acquired in a faster scan time (1:52 min) with twice the brain coverage. SAP-EPI showed motion-correction capability and some immunity to undersampling from rejected data. While 3D SAP-EPI suffers from some geometric distortion, its short scan time and motion-correction capability suggest that SAP-EPI may be a useful alternative to GRE and iEPI for use in SWI, particularly in uncooperative patients. © 2014 Wiley Periodicals, Inc.

  4. Echo-planar magnetic resonance imaging (EPI) with high-resolution matrix in intra-axial brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Bruening, R.; Scheidler, J.; Porn, U.; Reiser, M. [Institute of Diagnostic Radiology, Klinikum Grosshadern, University of Munich (Germany); Seelos, K.; Yousry, T. [Department of Neuroradiology, Institute of Diagnostic Radiology, Klinikum Grosshadern, University of Munich (Germany); Exner, H. [Institute for Medical Epidemiology, Klinikum Grosshadern, University of Munich, Munich (Germany); Rosen, B.R. [Department of Radiology, Massachusetts General Hospital, NMR Center, Charlestown, MA (United States)

    1999-09-01

    The aim of this study was to assess the potential of high-speed interleaved echo-planar imaging (EPI) to achieve diagnostic image quality comparable to T2-weighted imaging in patients with brain tumors. Seventeen patients with intra-axial, supratentorial tumors (10 untreated gliomas, 7 radiated gliomas) were investigated on a 1.5-T scanner. The conventional scan (SE, TR/TE = 2200/80 ms, 18 slices) was acquired in 8 min, 4 s, and EPI (TR/TE = 3000/80 ms, 18 slices) was completed in 25 s. The films were compared in a blinded trail by three radiologists. On the general impression and anatomic display, both sequences were rated to be of similar quality. Artifacts were slightly more pronounced at the skull base and around surgical clips using EPI. Tumor delineation was nearly equivalent using EPI, compared with the T2-weighted sequence. Echo-planar imaging reached diagnostic quality in all patients. Interleaved high-resolution EPI yielded sufficient quality to depict intra-axial, supratentorial brain tumors. Since EPI can be obtained in a small fraction of the time needed for conventional spin echo, in addition to other indications it could be considered to study patients unable to cooperate. (orig.) With 3 figs., 3 tabs., 27 refs.

  5. Echo-planar magnetic resonance imaging (EPI) with high-resolution matrix in intra-axial brain tumors

    International Nuclear Information System (INIS)

    Bruening, R.; Scheidler, J.; Porn, U.; Reiser, M.; Seelos, K.; Yousry, T.; Exner, H.; Rosen, B.R.

    1999-01-01

    The aim of this study was to assess the potential of high-speed interleaved echo-planar imaging (EPI) to achieve diagnostic image quality comparable to T2-weighted imaging in patients with brain tumors. Seventeen patients with intra-axial, supratentorial tumors (10 untreated gliomas, 7 radiated gliomas) were investigated on a 1.5-T scanner. The conventional scan (SE, TR/TE = 2200/80 ms, 18 slices) was acquired in 8 min, 4 s, and EPI (TR/TE = 3000/80 ms, 18 slices) was completed in 25 s. The films were compared in a blinded trail by three radiologists. On the general impression and anatomic display, both sequences were rated to be of similar quality. Artifacts were slightly more pronounced at the skull base and around surgical clips using EPI. Tumor delineation was nearly equivalent using EPI, compared with the T2-weighted sequence. Echo-planar imaging reached diagnostic quality in all patients. Interleaved high-resolution EPI yielded sufficient quality to depict intra-axial, supratentorial brain tumors. Since EPI can be obtained in a small fraction of the time needed for conventional spin echo, in addition to other indications it could be considered to study patients unable to cooperate. (orig.)

  6. Simultaneous multislice echo planar imaging with blipped controlled aliasing in parallel imaging results in higher acceleration: a promising technique for accelerated diffusion tensor imaging of skeletal muscle

    OpenAIRE

    Filli, Lukas; Piccirelli, Marco; Kenkel, David; Guggenberger, Roman; Andreisek, Gustav; Beck, Thomas; Runge, Val M; Boss, Andreas

    2015-01-01

    PURPOSE The aim of this study was to investigate the feasibility of accelerated diffusion tensor imaging (DTI) of skeletal muscle using echo planar imaging (EPI) applying simultaneous multislice excitation with a blipped controlled aliasing in parallel imaging results in higher acceleration unaliasing technique. MATERIALS AND METHODS After federal ethics board approval, the lower leg muscles of 8 healthy volunteers (mean [SD] age, 29.4 [2.9] years) were examined in a clinical 3-T magnetic ...

  7. Echo-Planar Imaging for a 9.4 Tesla Vertical-Bore Superconducting Magnet Using an Unshielded Gradient Coil.

    Science.gov (United States)

    Kodama, Nao; Kose, Katsumi

    2016-10-11

    Echo-planar imaging (EPI) sequences were developed for a 9.4 Tesla vertical standard bore (~54 mm) superconducting magnet using an unshielded gradient coil optimized for live mice imaging and a data correction technique with reference scans. Because EPI requires fast switching of intense magnetic field gradients, eddy currents were induced in the surrounding metallic materials, e.g., the room temperature bore, and this produced serious artifacts on the EPI images. We solved the problem using an unshielded gradient coil set of proper size (outer diameter = 39 mm, inner diameter = 32 mm) with time control of the current rise and reference scans. The obtained EPI images of a phantom and a plant sample were almost artifact-free and demonstrated the promise of our approach.

  8. Application of diffusion-weighted echo planar imaging for diagnosis of small acute and subacute brain ischemic lesions

    International Nuclear Information System (INIS)

    Enomoto, Kyoko; Watanabe, Tsuneya; Amanuma, Makoto; Heshiki, Atsuko

    1997-01-01

    The aim of this study was to determine the utility of diffusion-weighted echo planar imaging (DW-EPI) for detecting acute and subacute brain ischemic foci less than 2 cm in size. Thirty patients underwent DW-EPI on a 1.5 T super-conducting unit using a SE-EPI sequence with an arbitrary pair of Stejskal-Tanner gradients applied along the imaging axes. DW-EPI demonstrated all the mast recent ischemic lesions as areas of decreased diffusion, providing greater conspicuity and larger size than conventional spin-echo imaging. DW-EPI is a promising method to detect within a subsecond early ischemia and reversible ischemic changes that are not demonstrate on routine spin-echo images. (author)

  9. Echo-Planar Imaging for a 9.4 Tesla Vertical-Bore Superconducting Magnet Using an Unshielded Gradient Coil

    Science.gov (United States)

    KODAMA, Nao; KOSE, Katsumi

    2016-01-01

    Echo-planar imaging (EPI) sequences were developed for a 9.4 Tesla vertical standard bore (∼54 mm) superconducting magnet using an unshielded gradient coil optimized for live mice imaging and a data correction technique with reference scans. Because EPI requires fast switching of intense magnetic field gradients, eddy currents were induced in the surrounding metallic materials, e.g., the room temperature bore, and this produced serious artifacts on the EPI images. We solved the problem using an unshielded gradient coil set of proper size (outer diameter = 39 mm, inner diameter = 32 mm) with time control of the current rise and reference scans. The obtained EPI images of a phantom and a plant sample were almost artifact-free and demonstrated the promise of our approach. PMID:27001398

  10. Short repetition time multiband echo-planar imaging with simultaneous pulse recording allows dynamic imaging of the cardiac pulsation signal.

    Science.gov (United States)

    Tong, Yunjie; Hocke, Lia M; Frederick, Blaise deB

    2014-11-01

    Recently developed simultaneous multislice echo-planar imaging (EPI) sequences permit imaging of the whole brain at short repetition time (TR), allowing the cardiac fluctuations to be fully sampled in blood-oxygen-level dependent functional MRI (BOLD fMRI). A novel low computational analytical method was developed to dynamically map the passage of the pulsation signal through the brain and visualize the whole cerebral vasculature affected by the pulse signal. This algorithm is based on a simple combination of fast BOLD fMRI and the scanner's own built-in pulse oximeter. Multiple, temporally shifted copies of the pulse oximeter data (with 0.08 s shifting step and coverage of a 1-s span) were downsampled and used as cardiac pulsation regressors in a general linear model based analyses (FSL) of the fMRI data. The resulting concatenated z-statistics maps show the voxels that are affected as the cardiac signal travels through the brain. Many voxels were highly correlated with the pulsation regressor or its temporally shifted version. The dynamic and static cardiac pulsation maps obtained from both the task and resting state scans, resembled cerebral vasculature. The results demonstrated: (i) cardiac pulsation significantly affects most voxels in the brain; (ii) combining fast fMRI and this analytical method can reveal additional clinical information to functional studies. Copyright © 2013 Wiley Periodicals, Inc.

  11. In vivo carbon-edited detection with proton echo-planar spectroscopic imaging (ICED PEPSI) : [3,4-(CH2)-C-13] glutamate/glutamine tomography in rat brain

    NARCIS (Netherlands)

    Hyder, F; Renken, R; Rothman, DL

    1999-01-01

    A method for in vivo carbon-edited detection with proton echo-planar spectroscopic imaging (ICED PEPSI) is described. This method is composed of an echo-planar based acquisition implemented with C-13-H-1 J editing spectroscopy and is intended for high temporal and spatial resolution in vivo

  12. Concurrent correction of geometric distortion and motion using the map-slice-to-volume method in echo-planar imaging.

    Science.gov (United States)

    Yeo, Desmond T B; Fessler, Jeffrey A; Kim, Boklye

    2008-06-01

    The accuracy of measuring voxel intensity changes between stimulus and rest images in fMRI echo-planar imaging (EPI) data is severely degraded in the presence of head motion. In addition, EPI is sensitive to susceptibility-induced geometric distortions. Head motion causes image shifts and associated field map changes that induce different geometric distortion at different time points. Conventionally, geometric distortion is "corrected" with a static field map independently of image registration. That approach ignores all field map changes induced by head motion. This work evaluates the improved motion correction capability of mapping slice to volume with concurrent iterative field corrected reconstruction using updated field maps derived from an initial static field map that has been spatially transformed and resampled. It accounts for motion-induced field map changes for translational and in-plane rotation motion. The results from simulated EPI time series data, in which motion, image intensity and activation ground truths are available, show improved accuracy in image registration, field corrected image reconstruction and activation detection.

  13. Diuretic-enhanced gadolinium excretory MR urography: comparison of conventional gradient-echo sequences and echo-planar imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.C.A.; Tacke, J.; Adam, G.B.; Haage, P.; Guenther, R.W. [Univ. of Technology, Aachen (Germany). Dept. of Diagnostic Radiology; Jung, P.; Jakse, G. [Univ. of Technology, Aachen (Germany). Dept. of Urology

    2001-01-01

    The aim of this study was to investigate the utility of different gadolinium-enhanced T1-weighted gradient-echo techniques in excretory MR urography. In 74 urologic patients, excretory MR urography was performed using various T1-weighted gradient-echo (GRE) sequences after injection of gadolinium-DTPA and low-dose furosemide. The examinations included conventional GRE sequences and echo-planar imaging (GRE EPI), both obtained with 3D data sets and 2D projection images. Breath-hold acquisition was used primarily. In 20 of 74 examinations, we compared breath-hold imaging with respiratory gating. Breath-hold imaging was significantly superior to respiratory gating for the visualization of pelvicaliceal systems, but not for the ureters. Complete MR urograms were obtained within 14-20 s using 3D GRE EPI sequences and in 20-30 s with conventional 3D GRE sequences. Ghost artefacts caused by ureteral peristalsis often occurred with conventional 3D GRE imaging and were almost completely suppressed in EPI sequences (p < 0.0001). Susceptibility effects were more pronounced on GRE EPI MR urograms and calculi measured 0.8-21.7% greater in diameter compared with conventional GRE sequences. Increased spatial resolution degraded the image quality only in GRE-EPI urograms. (orig.)

  14. Diffusion-weighted imaging-guided MR spectroscopy in breast lesions using readout-segmented echo-planar imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Kun; Chai, Weimin; Zhan, Ying; Luo, Xianfu; Yan, Fuhua [Shanghai Jiao Tong University School of Medicine, Department of Radiology, Ruijin Hospital, Shanghai (China); Fu, Caixia [Siemens MRI Center, Siemens Shenzhen Magnetic Resonance Ltd, Shenzhen (China); Shen, Kunwei [Shanghai Jiao Tong University School of Medicine, Comprehensive Breast Health Center, Ruijin Hospital, Shanghai (China)

    2016-06-15

    To investigate the feasibility and effectiveness of diffusion-weighted imaging (DWI)-guided magnetic resonance spectroscopy (MRS) using readout-segmented echo-planar imaging (RS-EPI) to characterise breast lesions. A total of 258 patients with 258 suspicious breast lesions larger than 1 cm in diameter were examined using DWI-guided, single-voxel MRS with RS-EPI. The mean total choline-containing compound (tCho) signal-to-noise ratio (SNR) and concentration were used for the interpretation of MRS data. T-tests, χ{sup 2}-tests, receiver operating characteristic (ROC) curve analyses and Pearson correlations were conducted for statistical analysis. Histologically, 183 lesions were malignant, and 75 lesions were benign. Both the mean tCho SNR and concentration of malignant lesions were higher than those of benign lesions (6.23 ± 3.30 AU/mL vs. 1.26 ± 1.75 AU/mL and 3.17 ± 2.03 mmol/kg vs. 0.86 ± 0.83 mmol/kg, respectively; P < 0.0001). For a tCho SNR of 2.0 AU/mL and a concentration of 1.76 mmol/kg, the corresponding areas under the ROC curves were 0.93 and 0.90, respectively. The mean tCho SNR and concentration negatively correlated with apparent diffusion coefficients calculated from RS-EPI, with correlation coefficients of -0.54 and -0.48, respectively. DWI-guided MRS using RS-EPI is feasible and accurate for characterising breast lesions. (orig.)

  15. Accelerated three-dimensional cine phase contrast imaging using randomly undersampled echo planar imaging with compressed sensing reconstruction.

    Science.gov (United States)

    Basha, Tamer A; Akçakaya, Mehmet; Goddu, Beth; Berg, Sophie; Nezafat, Reza

    2015-01-01

    The aim of this study was to implement and evaluate an accelerated three-dimensional (3D) cine phase contrast MRI sequence by combining a randomly sampled 3D k-space acquisition sequence with an echo planar imaging (EPI) readout. An accelerated 3D cine phase contrast MRI sequence was implemented by combining EPI readout with randomly undersampled 3D k-space data suitable for compressed sensing (CS) reconstruction. The undersampled data were then reconstructed using low-dimensional structural self-learning and thresholding (LOST). 3D phase contrast MRI was acquired in 11 healthy adults using an overall acceleration of 7 (EPI factor of 3 and CS rate of 3). For comparison, a single two-dimensional (2D) cine phase contrast scan was also performed with sensitivity encoding (SENSE) rate 2 and approximately at the level of the pulmonary artery bifurcation. The stroke volume and mean velocity in both the ascending and descending aorta were measured and compared between two sequences using Bland-Altman plots. An average scan time of 3 min and 30 s, corresponding to an acceleration rate of 7, was achieved for 3D cine phase contrast scan with one direction flow encoding, voxel size of 2 × 2 × 3 mm(3) , foot-head coverage of 6 cm and temporal resolution of 30 ms. The mean velocity and stroke volume in both the ascending and descending aorta were statistically equivalent between the proposed 3D sequence and the standard 2D cine phase contrast sequence. The combination of EPI with a randomly undersampled 3D k-space sampling sequence using LOST reconstruction allows a seven-fold reduction in scan time of 3D cine phase contrast MRI without compromising blood flow quantification. Copyright © 2014 John Wiley & Sons, Ltd.

  16. In vivo measurement of regional brain metabolic response to hyperventilation using magnetic resonance: proton echo planar spectroscopic imaging (PEPSI).

    Science.gov (United States)

    Posse, S; Dager, S R; Richards, T L; Yuan, C; Ogg, R; Artru, A A; Müller-Gärtner, H W; Hayes, C

    1997-06-01

    A new rapid spectroscopic imaging technique with improved sensitivity and lipid suppression, referred to as Proton Echo Planar Spectroscopic Imaging (PEPSI), has been developed to measure the 2-dimensional distribution of brain lactate increases during hyperventilation on a conventional clinical scanner equipped with a head surface coil phased array. PEPSI images (nominal voxel size: 1.125 cm3) in five healthy subjects from an axial section approximately 20 mm inferior to the intercommissural line were obtained during an 8.5-min baseline period of normocapnia and during the final 8.5 min of a 10-min period of capnometry-controlled hyperventilation (end-tidal PCO2 of 20 mmHg). The lactate/N-acetyl aspartate signal increased significantly from baseline during hyperventilation for the insular cortex, temporal cortex, and occipital regions of both the right and left hemisphere, but not in the basal ganglia. Regional or hemispheric right-to-left differences were not found. The study extends previous work using single-voxel MR spectroscopy to dynamically study hyperventilation effects on brain metabolism.

  17. Fast mapping of the T2 relaxation time of cerebral metabolites using proton echo-planar spectroscopic imaging (PEPSI).

    Science.gov (United States)

    Tsai, Shang-Yueh; Posse, Stefan; Lin, Yi-Ru; Ko, Cheng-Wen; Otazo, Ricardo; Chung, Hsiao-Wen; Lin, Fa-Hsuan

    2007-05-01

    Metabolite T2 is necessary for accurate quantification of the absolute concentration of metabolites using long-echo-time (TE) acquisition schemes. However, lengthy data acquisition times pose a major challenge to mapping metabolite T2. In this study we used proton echo-planar spectroscopic imaging (PEPSI) at 3T to obtain fast T2 maps of three major cerebral metabolites: N-acetyl-aspartate (NAA), creatine (Cre), and choline (Cho). We showed that PEPSI spectra matched T2 values obtained using single-voxel spectroscopy (SVS). Data acquisition for 2D metabolite maps with a voxel volume of 0.95 ml (32 x 32 image matrix) can be completed in 25 min using five TEs and eight averages. A sufficient spectral signal-to-noise ratio (SNR) for T2 estimation was validated by high Pearson's correlation coefficients between logarithmic MR signals and TEs (R2 = 0.98, 0.97, and 0.95 for NAA, Cre, and Cho, respectively). In agreement with previous studies, we found that the T2 values of NAA, but not Cre and Cho, were significantly different between gray matter (GM) and white matter (WM; P PEPSI and SVS scans was less than 9%. Consistent spatial distributions of T2 were found in six healthy subjects, and disagreement among subjects was less than 10%. In summary, the PEPSI technique is a robust method to obtain fast mapping of metabolite T2. (c) 2007 Wiley-Liss, Inc.

  18. Single-shot polarimetry imaging of multicore fiber.

    Science.gov (United States)

    Sivankutty, Siddharth; Andresen, Esben Ravn; Bouwmans, Géraud; Brown, Thomas G; Alonso, Miguel A; Rigneault, Hervé

    2016-05-01

    We report an experimental test of single-shot polarimetry applied to the problem of real-time monitoring of the output polarization states in each core within a multicore fiber bundle. The technique uses a stress-engineered optical element, together with an analyzer, and provides a point spread function whose shape unambiguously reveals the polarization state of a point source. We implement this technique to monitor, simultaneously and in real time, the output polarization states of up to 180 single-mode fiber cores in both conventional and polarization-maintaining fiber bundles. We demonstrate also that the technique can be used to fully characterize the polarization properties of each individual fiber core, including eigen-polarization states, phase delay, and diattenuation.

  19. Magnetic resonance fingerprinting using echo-planar imaging: Joint quantification of T1 and T2∗ relaxation times.

    Science.gov (United States)

    Rieger, Benedikt; Zimmer, Fabian; Zapp, Jascha; Weingärtner, Sebastian; Schad, Lothar R

    2017-11-01

    To develop an implementation of the magnetic resonance fingerprinting (MRF) paradigm for quantitative imaging using echo-planar imaging (EPI) for simultaneous assessment of T 1 and T2∗. The proposed MRF method (MRF-EPI) is based on the acquisition of 160 gradient-spoiled EPI images with rapid, parallel-imaging accelerated, Cartesian readout and a measurement time of 10 s per slice. Contrast variation is induced using an initial inversion pulse, and varying the flip angles, echo times, and repetition times throughout the sequence. Joint quantification of T 1 and T2∗ is performed using dictionary matching with integrated B1+ correction. The quantification accuracy of the method was validated in phantom scans and in vivo in 6 healthy subjects. Joint T 1 and T2∗ parameter maps acquired with MRF-EPI in phantoms are in good agreement with reference measurements, showing deviations under 5% and 4% for T 1 and T2∗, respectively. In vivo baseline images were visually free of artifacts. In vivo relaxation times are in good agreement with gold-standard techniques (deviation T 1 : 4 ± 2%, T2∗: 4 ± 5%). The visual quality was comparable to the in vivo gold standard, despite substantially shortened scan times. The proposed MRF-EPI method provides fast and accurate T 1 and T2∗ quantification. This approach offers a rapid supplement to the non-Cartesian MRF portfolio, with potentially increased usability and robustness. Magn Reson Med 78:1724-1733, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  20. Accelerated proton echo planar spectroscopic imaging (PEPSI) using GRAPPA with a 32-channel phased-array coil.

    Science.gov (United States)

    Tsai, Shang-Yueh; Otazo, Ricardo; Posse, Stefan; Lin, Yi-Ru; Chung, Hsiao-Wen; Wald, Lawrence L; Wiggins, Graham C; Lin, Fa-Hsuan

    2008-05-01

    Parallel imaging has been demonstrated to reduce the encoding time of MR spectroscopic imaging (MRSI). Here we investigate up to 5-fold acceleration of 2D proton echo planar spectroscopic imaging (PEPSI) at 3T using generalized autocalibrating partial parallel acquisition (GRAPPA) with a 32-channel coil array, 1.5 cm(3) voxel size, TR/TE of 15/2000 ms, and 2.1 Hz spectral resolution. Compared to an 8-channel array, the smaller RF coil elements in this 32-channel array provided a 3.1-fold and 2.8-fold increase in signal-to-noise ratio (SNR) in the peripheral region and the central region, respectively, and more spatial modulated information. Comparison of sensitivity-encoding (SENSE) and GRAPPA reconstruction using an 8-channel array showed that both methods yielded similar quantitative metabolite measures (P > 0.1). Concentration values of N-acetyl-aspartate (NAA), total creatine (tCr), choline (Cho), myo-inositol (mI), and the sum of glutamate and glutamine (Glx) for both methods were consistent with previous studies. Using the 32-channel array coil the mean Cramer-Rao lower bounds (CRLB) were less than 8% for NAA, tCr, and Cho and less than 15% for mI and Glx at 2-fold acceleration. At 4-fold acceleration the mean CRLB for NAA, tCr, and Cho was less than 11%. In conclusion, the use of a 32-channel coil array and GRAPPA reconstruction can significantly reduce the measurement time for mapping brain metabolites. (c) 2008 Wiley-Liss, Inc.

  1. Accelerated echo-planar J-resolved spectroscopic imaging in the human brain using compressed sensing: a pilot validation in obstructive sleep apnea.

    Science.gov (United States)

    Sarma, M K; Nagarajan, R; Macey, P M; Kumar, R; Villablanca, J P; Furuyama, J; Thomas, M A

    2014-06-01

    Echo-planar J-resolved spectroscopic imaging is a fast spectroscopic technique to record the biochemical information in multiple regions of the brain, but for clinical applications, time is still a constraint. Investigations of neural injury in obstructive sleep apnea have revealed structural changes in the brain, but determining the neurochemical changes requires more detailed measurements across multiple brain regions, demonstrating a need for faster echo-planar J-resolved spectroscopic imaging. Hence, we have extended the compressed sensing reconstruction of prospectively undersampled 4D echo-planar J-resolved spectroscopic imaging to investigate metabolic changes in multiple brain locations of patients with obstructive sleep apnea and healthy controls. Nonuniform undersampling was imposed along 1 spatial and 1 spectral dimension of 4D echo-planar J-resolved spectroscopic imaging, and test-retest reliability of the compressed sensing reconstruction of the nonuniform undersampling data was tested by using a brain phantom. In addition, 9 patients with obstructive sleep apnea and 11 healthy controls were investigated by using a 3T MR imaging/MR spectroscopy scanner. Significantly reduced metabolite differences were observed between patients with obstructive sleep apnea and healthy controls in multiple brain regions: NAA/Cr in the left hippocampus; total Cho/Cr and Glx/Cr in the right hippocampus; total NAA/Cr, taurine/Cr, scyllo-Inositol/Cr, phosphocholine/Cr, and total Cho/Cr in the occipital gray matter; total NAA/Cr and NAA/Cr in the medial frontal white matter; and taurine/Cr and total Cho/Cr in the left frontal white matter regions. The 4D echo-planar J-resolved spectroscopic imaging technique using the nonuniform undersampling-based acquisition and compressed sensing reconstruction in patients with obstructive sleep apnea and healthy brain is feasible in a clinically suitable time. In addition to brain metabolite changes previously reported by 1D MR

  2. Quantitative mapping of total choline in healthy human breast using proton echo planar spectroscopic imaging (PEPSI) at 3 Tesla.

    Science.gov (United States)

    Zhao, Chenguang; Bolan, Patrick J; Royce, Melanie; Lakkadi, Navneeth; Eberhardt, Steven; Sillerud, Laurel; Lee, Sang-Joon; Posse, Stefan

    2012-11-01

    To quantitatively measure tCho levels in healthy breasts using Proton-Echo-Planar-Spectroscopic-Imaging (PEPSI). The two-dimensional mapping of tCho at 3 Tesla across an entire breast slice using PEPSI and a hybrid spectral quantification method based on LCModel fitting and integration of tCho using the fitted spectrum were developed. This method was validated in 19 healthy females and compared with single voxel spectroscopy (SVS) and with PRESS prelocalized conventional Magnetic Resonance Spectroscopic Imaging (MRSI) using identical voxel size (8 cc) and similar scan times (∼7 min). A tCho peak with a signal to noise ratio larger than 2 was detected in 10 subjects using both PEPSI and SVS. The average tCho concentration in these subjects was 0.45 ± 0.2 mmol/kg using PEPSI and 0.48 ± 0.3 mmol/kg using SVS. Comparable results were obtained in two subjects using conventional MRSI. High lipid content in the spectra of nine tCho negative subjects was associated with spectral line broadening of more than 26 Hz, which made tCho detection impossible. Conventional MRSI with PRESS prelocalization in glandular tissue in two of these subjects yielded tCho concentrations comparable to PEPSI. The detection sensitivity of PEPSI is comparable to SVS and conventional PRESS-MRSI. PEPSI can be potentially used in the evaluation of tCho in breast cancer. A tCho threshold concentration value of ∼0.7 mmol/kg might be used to differentiate between cancerous and healthy (or benign) breast tissues based on this work and previous studies. Copyright © 2012 Wiley Periodicals, Inc.

  3. Combining parallel detection of proton echo planar spectroscopic imaging (PEPSI) measurements with a data-consistency constraint improves SNR.

    Science.gov (United States)

    Tsai, Shang-Yueh; Hsu, Yi-Cheng; Chu, Ying-Hua; Kuo, Wen-Jui; Lin, Fa-Hsuan

    2015-12-01

    One major challenge of MRSI is the poor signal-to-noise ratio (SNR), which can be improved by using a surface coil array. Here we propose to exploit the spatial sensitivity of different channels of a coil array to enforce the k-space data consistency (DC) in order to suppress noise and consequently to improve MRSI SNR. MRSI data were collected using a proton echo planar spectroscopic imaging (PEPSI) sequence at 3 T using a 32-channel coil array and were averaged with one, two and eight measurements (avg-1, avg-2 and avg-8). The DC constraint was applied using a regularization parameter λ of 1, 2, 3, 5 or 10. Metabolite concentrations were quantified using LCModel. Our results show that the suppression of noise by applying the DC constraint to PEPSI reconstruction yields up to 32% and 27% SNR gain for avg-1 and avg-2 data with λ = 5, respectively. According to the reported Cramer-Rao lower bounds, the improvement in metabolic fitting was significant (p < 0.01) when the DC constraint was applied with λ ≥ 2. Using the DC constraint with λ = 3 or 5 can minimize both root-mean-square errors and spatial variation for all subjects using the avg-8 data set as reference values. Our results suggest that MRSI reconstructed with a DC constraint can save around 70% of scanning time to obtain images and spectra with similar SNRs using λ = 5. Copyright © 2015 John Wiley & Sons, Ltd.

  4. Ultra-high-speed imaging of the brain by the echo planar technique

    International Nuclear Information System (INIS)

    Worthington, B.S.; Stehling, M.K.; Ordidge, R.J.; Coxon, R.; Howseman, A.M.; Chapman, B.; Turner, R.; Firth, J.L.; Mansfield, P.

    1988-01-01

    Reduced examination time, greater patient tolerance and throughput, and the ability to study vascular and cerebrospinal fluid (CSF) flow phenomena are important advantages of ultra-high-speed brain imaging. The EPI derivatives BEST and MBEST create a complete 128 X 128-pixel image in 64 msec and 128 msec, respectively. In BEST images, T2 weighting is altered by adjusting the echo time, modulus BEST images have intrinsic T2 weighting. Repetition time alterations provide variable T1 weighting in both. Volunteer and patient studies illustrate how selective contrast manipulation allows excellent discrimination between gray and white matter and the brain and the CSF, enabling the demonstration of pathology

  5. The Usefulness of Readout-Segmented Echo-Planar Imaging (RESOLVE) for Bio-phantom Imaging Using 3-Tesla Clinical MRI.

    Science.gov (United States)

    Yoshimura, Yuuki; Kuroda, Masahiro; Sugiantoc, Irfan; Bamgbosec, Babatunde O; Miyahara, Kanae; Ohmura, Yuichi; Kurozumi, Akira; Matsushita, Toshi; Ohno, Seiichiro; Kanazawa, Susumu; Asaumi, Junichi

    2018-02-01

    Readout-segmented echo-planar imaging (RESOLVE) is a multi-shot echo-planar imaging (EPI) modality with k-space segmented in the readout direction. We investigated whether RESOLVE decreases the distortion and artifact in the phase direction and increases the signal-to-noise ratio (SNR) in phantoms image taken with 3-tesla (3T) MRI versus conventional EPI. We used a physiological saline phantom and subtraction mapping and observed that RESOLVE's SNR was higher than EPI's. Using RESOLVE, the combination of a special-purpose coil and a large-loop coil had a higher SNR compared to using only a head/neck coil. RESOLVE's image distortioas less than EPI's. We used a 120 mM polyethylene glycol phantom to examine the phase direction artifact.vThe range where the artifact appeared in the apparent diffusion coefficient (ADC) image was shorter with RESOLVE compared to EPI. We used RESOLVE to take images of a Jurkat cell bio-phantom: the cell-region ADC was 856×10-6mm2/sec and the surrounding physiological saline-region ADC was 2,951×10-6mm2/sec. The combination of RESOLVE and the 3T clinical MRI device reduced image distortion and improved SNR and the identification of accurate ADC values due to the phase direction artifact reduction. This combination is useful for obtaining accurate ADC values of bio-phantoms.

  6. Diffusion-weighted echo planar imaging in patients with recent myocardial infarction

    International Nuclear Information System (INIS)

    Deux, Jean-Francois; Maatouk, Mezri; Luciani, Alain; Lenczner, Gregory; Mayer, Julie; Kobeiter, Hicham; Rahmouni, Alain; Vignaud, Alexandre; Lim, Pascal; Dubois-Rande, Jean-Luc

    2011-01-01

    To evaluate a diffusion-weighted (DW) black blood MR sequence for the detection of myocardium signal abnormalities in patients with recent myocardial infarction (MI). A DW black blood EPI sequence was acquired at 1.5 T in 12 patients with recent MI. One slice per patient was acquired with b = 0 and b = 50 s/mm 2 . A standard short tau inversion recovery (STIR) T2-weighted sequence was acquired at the same level. Viability was assessed with delayed-enhancement sequences. Images were analyzed qualitatively and quantitatively. A non parametric Wilcoxon test was used for statistical analysis, with a significance level of P <.05. The mean quality of blood suppression was higher on DW EPI images than on STIR T2-weighted images (3.9 ± 0.3 and 3.0 ± 0.7, respectively; P = 0.01). Myocardial high signal areas were detected in respectively 100% (12/12) and 67% (8/12) of the patients on DW EPI and STIR T2-weighted images. The four patients (33%) with false-negative STIR T2 findings all had high signal areas on DW EPI images corresponding to the location of the MI on the delayed-enhanced images. DW EPI sequences are a feasible alternative to standard STIR T2-weighted sequences for detecting myocardium high signal areas in patients with recent MI. (orig.)

  7. Time efficient whole-brain coverage with MR Fingerprinting using slice-interleaved echo-planar-imaging.

    Science.gov (United States)

    Rieger, Benedikt; Akçakaya, Mehmet; Pariente, José C; Llufriu, Sara; Martinez-Heras, Eloy; Weingärtner, Sebastian; Schad, Lothar R

    2018-04-27

    Magnetic resonance fingerprinting (MRF) is a promising method for fast simultaneous quantification of multiple tissue parameters. The objective of this study is to improve the coverage of MRF based on echo-planar imaging (MRF-EPI) by using a slice-interleaved acquisition scheme. For this, the MRF-EPI is modified to acquire several slices in a randomized interleaved manner, increasing the effective repetition time of the spoiled gradient echo readout acquisition in each slice. Per-slice matching of the signal-trace to a precomputed dictionary allows the generation of T 1 and T 2 * maps with integrated B 1 + correction. Subsequent compensation for the coil sensitivity profile and normalization to the cerebrospinal fluid additionally allows for quantitative proton density (PD) mapping. Numerical simulations are performed to optimize the number of interleaved slices. Quantification accuracy is validated in phantom scans and feasibility is demonstrated in-vivo. Numerical simulations suggest the acquisition of four slices as a trade-off between quantification precision and scan-time. Phantom results indicate good agreement with reference measurements (Difference T 1 : -2.4 ± 1.1%, T 2 *: -0.5 ± 2.5%, PD: -0.5 ± 7.2%). In-vivo whole-brain coverage of T 1 , T 2 * and PD with 32 slices was acquired within 3:36 minutes, resulting in parameter maps of high visual quality and comparable performance with single-slice MRF-EPI at 4-fold scan-time reduction.

  8. Reducing task-based fMRI scanning time using simultaneous multislice echo planar imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kiss, Mate [Hungarian Academy of Sciences, Brain Imaging Centre, Research Centre for Natural Sciences, Budapest (Hungary); Janos Szentagothai PhD School, MR Research Centre, Budapest (Hungary); National Institute of Clinical Neuroscience, Department of Neuroradiology, Budapest (Hungary); Hermann, Petra; Vidnyanszky, Zoltan; Gal, Viktor [Hungarian Academy of Sciences, Brain Imaging Centre, Research Centre for Natural Sciences, Budapest (Hungary)

    2018-03-15

    To maintain alertness and to remain motionless during scanning represent a substantial challenge for patients/subjects involved in both clinical and research functional magnetic resonance imaging (fMRI) examinations. Therefore, availability and application of new data acquisition protocols allowing the shortening of scan time without compromising the data quality and statistical power are of major importance. Higher order category-selective visual cortical areas were identified individually, and rapid event-related fMRI design was used to compare three different sampling rates (TR = 2000, 1000, and 410 ms, using state-of-the-art simultaneous multislice imaging) and four different scanning lengths to match the statistical power of the traditional scanning methods to high sampling-rate design. The results revealed that ∝ 4 min of the scan time with 1 Hz (TR = 1000 ms) sampling rate and ∝ 2 min scanning at ∝ 2.5 Hz (TR = 410 ms) sampling rate provide similar localization sensitivity and selectivity to that obtained with 11-min session at conventional, 0.5 Hz (TR = 2000 ms) sampling rate. Our findings suggest that task-based fMRI examination of clinical population prone to distress such as presurgical mapping experiments might substantially benefit from the reduced (20-40%) scanning time that can be achieved by the application of simultaneous multislice sequences. (orig.)

  9. Usefulness and limitation of functional MRI with echo planar imaging using clinical MR apparatus

    International Nuclear Information System (INIS)

    Kusunoki, Katsusuke; Zenke, Kiichiro; Saito, Masahiro; Sadamoto, Kazuhiko; Ohue, Shiro; Sakaki, Saburo; Kumon, Yoshiaki; Kabasawa, Hiroyuki; Nagasawa, Kiyoshi

    1998-01-01

    We studied blood oxygen level-dependent (BOLD) functional MRI (fMRI) with EPI sequence in 21 normal volunteers and 8 presurgical clinical patients using a 1.5 T clinical MRI apparatus. To optimize the imaging parameters, we compared the fMRI images obtained by GFE-EPI and by SE-EPI in normal volunteers while each squeezed a sponge ball. We identified the motor cortex in 85.7% of normal volunteers by GFE-EPI in contrast to only 28.6% by SE-EPI. In addition, our clinical MR apparatus, using optimized parameters, maximally provides 15 slices per 5 seconds. In patients with brain tumor close to the sensorimotor cortex, we attempted to identify the motor cortex preoperatively by this procedure and found a significant increase of signal intensity in the motor cortex in 5 of 8 patients. In conclusion, fMRI using EPI may be useful for identifying the motor cortex preoperatively. However, further development of the apparatus is needed to obtain better temporal and spatial resolution for clinical applications. (author)

  10. Short-scan-time multi-slice diffusion MRI of the mouse cervical spinal cord using echo planar imaging.

    Science.gov (United States)

    Callot, Virginie; Duhamel, Guillaume; Cozzone, Patrick J; Kober, Frank

    2008-10-01

    Mouse spinal cord (SC) diffusion-weighted imaging (DWI) provides important information on tissue morphology and structural changes that may occur during pathologies such as multiple sclerosis or SC injury. The acquisition scheme of the commonly used DWI techniques is based on conventional spin-echo encoding, which is time-consuming. The purpose of this work was to investigate whether the use of echo planar imaging (EPI) would provide good-quality diffusion MR images of mouse SC, as well as accurate measurements of diffusion-derived metrics, and thus enable diffusion tensor imaging (DTI) and highly resolved DWI within reasonable scan times. A four-shot diffusion-weighted spin-echo EPI (SE-EPI) sequence was evaluated at 11.75 T on a group of healthy mice (n = 10). SE-EPI-derived apparent diffusion coefficients of gray and white matter were compared with those obtained using a conventional spin-echo sequence (c-SE) to validate the accuracy of the method. To take advantage of the reduction in acquisition time offered by the EPI sequence, multi-slice DTI acquisitions were performed covering the cervical segments (six slices, six diffusion-encoding directions, three b values) within 30 min (vs 2 h for c-SE). From these measurements, fractional anisotropy and mean diffusivities were calculated, and fiber tracking along the C1 to C6 cervical segments was performed. In addition, high-resolution images (74 x 94 microm(2)) were acquired within 5 min per direction. Clear delineation of gray and white matter and identical apparent diffusion coefficient values were obtained, with a threefold reduction in acquisition time compared with c-SE. While overcoming the difficulties associated with high spatially and temporally resolved DTI measurements, the present SE-EPI approach permitted identification of reliable quantitative parameters with a reproducibility compatible with the detection of pathologies. The SE-EPI method may be particularly valuable when multiple sets of images

  11. Short- and long-term quantitation reproducibility of brain metabolites in the medial wall using proton echo planar spectroscopic imaging.

    Science.gov (United States)

    Tsai, Shang-Yueh; Lin, Yi-Ru; Wang, Woan-Chyi; Niddam, David M

    2012-11-15

    Proton echo planar spectroscopic imaging (PEPSI) is a fast magnetic resonance spectroscopic imaging (MRSI) technique that allows mapping spatial metabolite distributions in the brain. Although the medial wall of the cortex is involved in a wide range of pathological conditions, previous MRSI studies have not focused on this region. To decide the magnitude of metabolic changes to be considered significant in this region, the reproducibility of the method needs to be established. The study aims were to establish the short- and long-term reproducibility of metabolites in the right medial wall and to compare regional differences using a constant short-echo time (TE30) and TE averaging (TEavg) optimized to yield glutamatergic information. 2D sagittal PEPSI was implemented at 3T using a 32 channel head coil. Acquisitions were repeated immediately and after approximately 2 weeks to assess the coefficients of variation (COV). COVs were obtained from eight regions-of-interest (ROIs) of varying size and location. TE30 resulted in better spectral quality and similar or lower quantitation uncertainty for all metabolites except glutamate (Glu). When Glu and glutamine (Gln) were quantified together (Glx) reduced quantitation uncertainty and increased reproducibility was observed for TE30. TEavg resulted in lowered quantitation uncertainty for Glu but in less reliable quantification of several other metabolites. TEavg did not result in a systematically improved short- or long-term reproducibility for Glu. The ROI volume was a major factor influencing reproducibility. For both short- and long-term repetitions, the Glu COVs obtained with TEavg were 5-8% for the large ROIs, 12-17% for the medium sized ROIs and 16-26% for the smaller cingulate ROIs. COVs obtained with TE30 for the less specific Glx were 3-5%, 8-10% and 10-15%. COVs for N-acetyl aspartate, creatine and choline using TE30 with long-term repetition were between 2-10%. Our results show that the cost of more specific

  12. Dynamic multi-coil technique (DYNAMITE) shimming for echo-planar imaging of the human brain at 7 Tesla.

    Science.gov (United States)

    Juchem, Christoph; Umesh Rudrapatna, S; Nixon, Terence W; de Graaf, Robin A

    2015-01-15

    Gradient-echo echo-planar imaging (EPI) is the primary method of choice in functional MRI and other methods relying on fast MRI to image brain activation and connectivity. However, the high susceptibility of EPI towards B0 magnetic field inhomogeneity poses serious challenges. Conventional magnetic field shimming with low-order spherical harmonic (SH) functions is capable of compensating shallow field distortions, but performs poorly for global brain shimming or on specific areas with strong susceptibility-induced B0 distortions such as the prefrontal cortex (PFC). Excellent B0 homogeneity has been demonstrated recently in the human brain at 7 Tesla with the DYNAmic Multi-coIl TEchnique (DYNAMITE) for magnetic field shimming (J Magn Reson (2011) 212:280-288). Here, we report the benefits of DYNAMITE shimming for multi-slice EPI and T2* mapping. A standard deviation of 13Hz was achieved for the residual B0 distribution in the human brain at 7 Tesla with DYNAMITE shimming and was 60% lower compared to conventional shimming that employs static zero through third order SH shapes. The residual field inhomogeneity with SH shimming led to an average 8mm shift at acquisition parameters commonly used for fMRI and was reduced to 1.5-3mm with DYNAMITE shimming. T2* values obtained from the prefrontal and temporal cortices with DYNAMITE shimming were 10-50% longer than those measured with SH shimming. The reduction of the confounding macroscopic B0 field gradients with DYNAMITE shimming thereby promises improved access to the relevant microscopic T2* effects. The combination of high spatial resolution and DYNAMITE shimming allows largely artifact-free EPI and T2* mapping throughout the brain, including prefrontal and temporal lobe areas. DYNAMITE shimming is expected to critically benefit a wide range of MRI applications that rely on excellent B0 magnetic field conditions including EPI-based fMRI to study various cognitive processes and assessing large-scale brain connectivity

  13. Dynamic Multi-Coil Technique (DYNAMITE) Shimming for Echo-Planar Imaging of the Human Brain at 7 Tesla

    Science.gov (United States)

    Juchem, Christoph; Rudrapatna, S. Umesh; Nixon, Terence W.; de Graaf, Robin A.

    2014-01-01

    Gradient-echo echo-planar imaging (EPI) is the primary method of choice in functional MRI and other methods relying on fast MRI to image brain activation and connectivity. However, the high susceptibility of EPI towards B0 magnetic field inhomogeneity poses serious challenges. Conventional magnetic field shimming with low-order spherical harmonic (SH) functions is capable of compensating shallow field distortions, but performs poorly for global brain shimming or on specific areas with strong susceptibility-induced B0 distortions such as the prefrontal cortex (PFC). Excellent B0 homogeneity has been demonstrated recently in the human brain at 7 Tesla with the DYNAmic Multi-coIl TEchnique (DYNAMITE) for magnetic field shimming (Juchem et al., J Magn Reson (2011) 212:280-288). Here, we report the benefits of DYNAMITE shimming for multi-slice EPI and T2* mapping. A standard deviation of 13 Hz was achieved for the residual B0 distribution in the human brain at 7 Tesla with DYNAMITE shimming and was 60% lower compared to conventional shimming that employs static zero through third order SH shapes. The residual field inhomogeneity with SH shimming led to an average 8 mm shift at acquisition parameters commonly used for fMRI and was reduced to 1.5-3 mm with DYNAMITE shimming. T2* values obtained from the prefrontal and temporal cortices with DYNAMITE shimming were 10-50% longer than those measured with SH shimming. The reduction of the confounding macroscopic B0 field gradients with DYNAMITE shimming thereby promises improved access to the relevant microscopic T2* effects. The combination of high spatial resolution and DYNAMITE shimming allows largely artifact-free EPI and T2* mapping throughout the brain, including prefrontal and temporal lobe areas. DYNAMITE shimming is expected to critically benefit a wide range of MRI applications that rely on excellent B0 magnetic field conditions including EPI-based fMRI to study various cognitive processes and assessing large

  14. Experimental considerations on the removal of alimentary tract signal in T2 multi shot inversion recovery echo planar imaging using ferric ammonium citrate as contrast agent

    International Nuclear Information System (INIS)

    Kato, Joji; Saito, Haruyoshi; Tomisato, Kenichi; Maruyama, Tomoyuki; Watanabe, Tsuneo; Kawamura, Yoshihiko

    1997-01-01

    We investigated the removal of alimentary tract signal in T 2 echo planar imaging using an oral positive contrast agent for the alimentary tract mainly consisting of ferric ammonium citrate (FerriSeltz: Otsuka Pharmaceutical Co., Ltd.). It has been reported that the FerriSeltz preparation is useful as negative contrast agent because of its enhancing effect of reducing T 2 at high concentrations. However, it was shown to enhance susceptibility artifact in echo planar imaging (EPI). Thus, it is considered difficult to use FerriSeltz at high concentrations in EPI. In contrast, in IR EPI (TI 150 and 200 ms) high concentrations of FerriSeltz are not required, and it is possible to achieve excellent signal suppression at an ordinary concentration of 5.97 mmol/l. This might be due to the fact that the bounce point of FerriSeltz aqueous solution reached about 150 to 200 ms. At present, no effective negative contrast agent for alimentary tract MRI is available. Therefore, it is thought that IR EPI combined with FerriSeltz is a useful technique, since it can eliminate the signal of the alimentary tract at an ordinary concentration. (author)

  15. Algorithms for image recovery calculation in extended single-shot phase-shifting digital holography

    Science.gov (United States)

    Hasegawa, Shin-ya; Hirata, Ryo

    2018-04-01

    The single-shot phase-shifting method of image recovery using an inclined reference wave has the advantages of reducing the effects of vibration, being capable of operating in real time, and affording low-cost sensing. In this method, relatively low reference angles compared with that in the conventional method using phase shift between three or four pixels has been required. We propose an extended single-shot phase-shifting technique which uses the multiple-step phase-shifting algorithm and the corresponding multiple pixels which are the same as that of the period of an interference fringe. We have verified the theory underlying this recovery method by means of Fourier spectral analysis and its effectiveness by evaluating the visibility of the image using a high-resolution pattern. Finally, we have demonstrated high-contrast image recovery experimentally using a resolution chart. This method can be used in a variety of applications such as color holographic interferometry.

  16. Liver imaging at 3.0 T: Diffusion-induced black-blood echo-planar imaging with large anatomic volumetric coverage as an alternative for specific absorption rate-intensive echo-train spin-echo sequences: Feasibility study

    NARCIS (Netherlands)

    I.C. van den Bos (Indra); S.M. Hussain (Shahid); G.P. Krestin (Gabriel); P.A. Wielopolski (Piotr)

    2008-01-01

    textabstractInstitutional Review Board approval and signed informed consent were obtained by all participants for an ongoing sequence optimization project at 3.0 T. The purpose of this study was to evaluate breath-hold diffusion-induced blackblood echo-planar imaging (BBEPI) as a potential

  17. Comparison of Turbo Spin Echo and Echo Planar Imaging for intravoxel incoherent motion and diffusion tensor imaging of the kidney at 3 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Hilbert, Fabian; Wech, Tobias; Neubauer, Henning; Veldhoen, Simon; Bley, Thorsten Alexander; Koestler, Herbert [Wuerzburg Univ. (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie

    2017-10-01

    Echo Planar Imaging (EPI) is most commonly applied to acquire diffusion-weighted MR-images. EPI is able to capture an entire image in very short time, but is prone to distortions and artifacts. In diffusion-weighted EPI of the kidney severe distortions may occur due to intestinal gas. Turbo Spin Echo (TSE) is robust against distortions and artifacts, but needs more time to acquire an entire image compared to EPI. Therefore, TSE is more sensitive to motion during the readout. In this study we compare diffusion-weighted TSE and EPI of the human kidney with regard to intravoxel incoherent motion (IVIM) and diffusion tensor imaging (DTI). Images were acquired with b-values between 0 and 750 s/mm{sup 2} with TSE and EPI. Distortions were observed with the EPI readout in all volunteers, while the TSE images were virtually distortion-free. Fractional anisotropy of the diffusion tensor was significantly lower for TSE than for EPI. All other parameters of DTI and IVIM were comparable for TSE and EPI. Especially the main diffusion directions yielded by TSE and EPI were similar. The results demonstrate that TSE is a worthwhile distortion-free alternative to EPI for diffusion-weighted imaging of the kidney at 3 Tesla.

  18. In vivo carbon-edited detection with proton echo-planar spectroscopic imaging (ICED PEPSI): [3,4-(13)CH(2)]glutamate/glutamine tomography in rat brain.

    Science.gov (United States)

    Hyder, F; Renken, R; Rothman, D L

    1999-12-01

    A method for in vivo carbon-edited detection with proton echo-planar spectroscopic imaging (ICED PEPSI) is described. This method is composed of an echo-planar based acquisition implemented with (13)C-(1)H J editing spectroscopy and is intended for high temporal and spatial resolution in vivo spectroscopic imaging of (13)C turnover, from D-[1,6-(13)C]glucose to glutamate and glutamine, in the brain. At a static magnetic field strength of 7 T, both in vitro and in vivo chemical shift imaging data are presented with a spatial resolution of 8 microL (i.e., 1.25 x 1.25 x 5.00 mm(3)) and a maximum spectral bandwidth of 5.2 ppm in (1)H. Chemical shift imaging data acquired every 11 minutes allowed detection of regional [4-(13)CH(2)]glutamate turnover in rat brain. The [4-(13)CH(2)]glutamate turnover curves, which can be converted to tricarboxylic acid cycle fluxes, showed that the tricarboxylic acid cycle flux (V(TCA)) in pure gray and white matter can range from 1.2 +/- 0.2 to 0.5 +/- 0.1 micromol/g/min, respectively, for morphine-anesthetized rats. The mean cortical V(TCA) from 32 voxels of 1.0 +/- 0.3 micromol/g/min (N = 3) is in excellent agreement with previous localized measurements that have demonstrated that V(TCA) can range from 0.9-1.1 micromol/g/min under identical anesthetized conditions. Magn Reson Med 42:997-1003, 1999. Copyright 1999 Wiley-Liss, Inc.

  19. Regional cerebral blood volume (rCBV) in the cerebral and cerebellar hemispheres in nomal 52 healthy adults. Measurement with contrast-enhanced dynamic echo-planar imaging

    Energy Technology Data Exchange (ETDEWEB)

    Muroi, Kenzo; Kurihara, Hiroaki; Amauchi, Hiroshi; Nozawa, Takeo; Matsubara, Sho; Yamamoto, Isao [Yokohama City Univ. (Japan). Hospital; Iwasawa, Tae

    2001-05-01

    The aim of this study was to investigate the possibility of absolute quantification of mean transit time (MTT) and rCBV in normal 52 healthy adults using contrast-enhanced dynamic echo-planar imaging, changes in signals in the middle cerebral arteries (MCAs) in the Sylvian fissures as AIF. MR was performed with a 1.5 T magnet (Horizon, GE Medical System, Milwaukee, WI). Dynamic susceptibility contrast-enhanced imaging was obtained every 1.8 second using echo-planar imaging (EPI) sequence (TE=42 msec, matrices=128 x 128) in six slices (6 mm slice thickness with 10 mm gap) including the cerebellar hemisphere at the level of middle cerebellar peduncles. The regional cerebral blood volume (rCBV) was calculated based on dilution theory. We calculated rCBV of the cerebral white matter (WM), cortical gray matter (GM), and cerebellar hemispheres (CH), and the effect of age on MTT and rCBV were evaluated linear regression analyses. The MTT of MCAs did not change with age, and the area under the curve of MCAs declined slightly with age. The mean rCBV of cortical GM, cerebral WM and cerebellar hemispheres were 8.2{+-}2.8, 2.0{+-}0.8 and 8.8{+-}2.1 respectively. The rCBV of cortical GM and the CH decreased slightly with age, however, that of WM remained to be a greater extent than those in GM. From these results, the method using AIF determined in bilateral MCAs was considered as an practical approach for the quantification of rCBV. Further clinical and/or comparative studies with other modalities will be necessary for the application of this method for patients with atherosclerosis and/or major vessel occlusion. (author)

  20. Comparison of intravoxel incoherent motion diffusion-weighted imaging between turbo spin-echo and echo-planar imaging of the head and neck

    Energy Technology Data Exchange (ETDEWEB)

    Mikayama, Ryoji; Yabuuchi, Hidetake; Nagatomo, Kazuya; Kimura, Mitsuhiro; Kumazawa, Seiji [Kyushu University, Department of Health Sciences, Graduate School of Medical Sciences, Fukuoka (Japan); Sonoda, Shinjiro; Kobayashi, Koji [Kyushu University Hospital, Division of Radiology, Department of Medical Technology, Fukuoka (Japan); Kawanami, Satoshi; Kamitani, Takeshi; Honda, Hiroshi [Kyushu University, Department of Clinical Radiology, Graduate School of Medical Sciences, Fukuoka (Japan)

    2018-01-15

    To compare image quality, apparent diffusion coefficient (ADC), and intravoxel incoherent motion (IVIM)-derived parameters between turbo spin-echo (TSE)-diffusion-weighted imaging (DWI) and echo-planar imaging (EPI)-DWI of the head and neck. Fourteen volunteers underwent head and neck imaging using TSE-DWI and EPI-DWI. Distortion ratio (DR), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), ADC and IVIM-derived parameters were compared between the two techniques. Bland-Altman analysis was performed to analyse reproducibility between the quantitative parameters of TSE-DWI and EPI-DWI. DR of TSE-DWI was significantly smaller than that of EPI-DWI. SNR and CNR of TSE-DWI were significantly higher than those of EPI-DWI. ADC and IVIM-derived parameters of TSE-DWI showed higher values than those of EPI-DWI, although the difference was not significant. Bland-Altman analysis showed wide limits of agreement between the two sequences. TSE-DWI can produce better image quality than EPI-DWI, while TSE-DWI possibly exhibits different values of quantitative parameters. Therefore, TSE-DWI could be a good alternative to EPI-DWI for patients sensitive to distortion. However, it is not recommended to use both TSE-DWI and EPI-DWI on follow-up. (orig.)

  1. Simultaneous Multislice Echo Planar Imaging With Blipped Controlled Aliasing in Parallel Imaging Results in Higher Acceleration: A Promising Technique for Accelerated Diffusion Tensor Imaging of Skeletal Muscle.

    Science.gov (United States)

    Filli, Lukas; Piccirelli, Marco; Kenkel, David; Guggenberger, Roman; Andreisek, Gustav; Beck, Thomas; Runge, Val M; Boss, Andreas

    2015-07-01

    The aim of this study was to investigate the feasibility of accelerated diffusion tensor imaging (DTI) of skeletal muscle using echo planar imaging (EPI) applying simultaneous multislice excitation with a blipped controlled aliasing in parallel imaging results in higher acceleration unaliasing technique. After federal ethics board approval, the lower leg muscles of 8 healthy volunteers (mean [SD] age, 29.4 [2.9] years) were examined in a clinical 3-T magnetic resonance scanner using a 15-channel knee coil. The EPI was performed at a b value of 500 s/mm2 without slice acceleration (conventional DTI) as well as with 2-fold and 3-fold acceleration. Fractional anisotropy (FA) and mean diffusivity (MD) were measured in all 3 acquisitions. Fiber tracking performance was compared between the acquisitions regarding the number of tracks, average track length, and anatomical precision using multivariate analysis of variance and Mann-Whitney U tests. Acquisition time was 7:24 minutes for conventional DTI, 3:53 minutes for 2-fold acceleration, and 2:38 minutes for 3-fold acceleration. Overall FA and MD values ranged from 0.220 to 0.378 and 1.595 to 1.829 mm2/s, respectively. Two-fold acceleration yielded similar FA and MD values (P ≥ 0.901) and similar fiber tracking performance compared with conventional DTI. Three-fold acceleration resulted in comparable MD (P = 0.199) but higher FA values (P = 0.006) and significantly impaired fiber tracking in the soleus and tibialis anterior muscles (number of tracks, P DTI of skeletal muscle with similar image quality and quantification accuracy of diffusion parameters. This may increase the clinical applicability of muscle anisotropy measurements.

  2. Identification of the primary motor cortex: value of T2 echo-planar imaging, diffusion-weighted imaging and quantitative apparent diffusion coefficient measurement at 3 T

    International Nuclear Information System (INIS)

    Dincer, Alp; Erzen, Canan; Oezyurt, Onur; Pamir, M.N.

    2010-01-01

    To investigate the primary motor cortex (PMC) concerning T2 shortening on T2 echo-planar imaging (EPI-T2) and the double-layer sign on diffusion-weighted imaging (DWI), and also to measure its apparent diffusion coefficient (ADC). 3-T MR DWI was performed in 134 adult volunteers and 64 patients. T2 shortening was graded as hypointense or isointense compared with the signal of the superior frontal cortex (SFC). The double-layer sign of the PMC was graded as present or absent. Both findings (T2 shortening and double-layer sign) were evaluated independently by two authors. ADC of the PMC and the SFC were calculated using manually selected ROIs. T2 shortening was found in 131 adults and 62 patients by author 1 and in 132 adults and 61 patients by author 2 (κ = 0.96 and 0.91). The double-layer sign was found in 131 adults and 61 patients by author 1 and in 127 adults and 58 patients by author 2 (κ = 0.94 and 0.91). ADC values of the PMC and the SFC were different for all subjects (p < 0.01). T2 shortening and/or the double-layer sign on 3-T MR can be used to locate the PMC. The difference in ADC values between PMC and SFC is a distinguishing feature. (orig.)

  3. Fourier Analysis of Single-Shot Dual-Energy X-ray Imaging Characteristics

    International Nuclear Information System (INIS)

    Kim, Jun Woo; Kim, Dong Woon; Kim, Ho Kyung

    2016-01-01

    The sandwich detector was realized by stacking two scintillator-based flat-panel detectors (FPDs) between which an intermediate copper (Cu) filter layer was placed to further enhance spectral energy separation. As a result, the proper selection of filter material and its thickness could be a trade-off between the extent of energy separation (hence, DE image quality) and image noise due to reduction in the number of x-ray quanta reaching the rear FPD. Although the conventional kVp-switching dual-shot method showed better image qualities than the single-shot method because of larger spectral energy separation, the motion-artifact-free DE image with reasonably good image quality was a potential prospect of the single-shot method. For the reliable and better use of the sandwich detector for specific imaging applications, the sandwich detector should be optimally designed with a proper selection of scintillator material and thickness in each detector layer (i.e. the front and rear detectors), and aforementioned intermediate filter material and thickness. It is noted that glue is used to adhere the fragile photodiode array onto the ceramic substrate and these glue patterns are apparent in the rear and DE images. The glue pattern in the rear image comes from the front FPD. Unlike the conventional ESF as shown in Fig. 3(a), the ESF obtained from the subtracted image showed an enhancement as shown in Fig. 3(b). Consequently, the MTF obtained from the subtraction ESF showed a bandpass filter characteristic, as shown in Fig. 3(c), unlike the conventional low-pass filter characteristic (i.e., monotonic decrease of MTF value with increasing the spatial frequency). This MTF characteristic is due to the subtraction of two images with different spatial resolving powers (i.e., different thicknesses of phosphors between the front and rear detectors) as can be seen in unsharp masking digital image processing, which subtracts Gaussian-blurred image from the original image

  4. Fourier Analysis of Single-Shot Dual-Energy X-ray Imaging Characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jun Woo; Kim, Dong Woon; Kim, Ho Kyung [Pusan National University, Busan (Korea, Republic of)

    2016-05-15

    The sandwich detector was realized by stacking two scintillator-based flat-panel detectors (FPDs) between which an intermediate copper (Cu) filter layer was placed to further enhance spectral energy separation. As a result, the proper selection of filter material and its thickness could be a trade-off between the extent of energy separation (hence, DE image quality) and image noise due to reduction in the number of x-ray quanta reaching the rear FPD. Although the conventional kVp-switching dual-shot method showed better image qualities than the single-shot method because of larger spectral energy separation, the motion-artifact-free DE image with reasonably good image quality was a potential prospect of the single-shot method. For the reliable and better use of the sandwich detector for specific imaging applications, the sandwich detector should be optimally designed with a proper selection of scintillator material and thickness in each detector layer (i.e. the front and rear detectors), and aforementioned intermediate filter material and thickness. It is noted that glue is used to adhere the fragile photodiode array onto the ceramic substrate and these glue patterns are apparent in the rear and DE images. The glue pattern in the rear image comes from the front FPD. Unlike the conventional ESF as shown in Fig. 3(a), the ESF obtained from the subtracted image showed an enhancement as shown in Fig. 3(b). Consequently, the MTF obtained from the subtraction ESF showed a bandpass filter characteristic, as shown in Fig. 3(c), unlike the conventional low-pass filter characteristic (i.e., monotonic decrease of MTF value with increasing the spatial frequency). This MTF characteristic is due to the subtraction of two images with different spatial resolving powers (i.e., different thicknesses of phosphors between the front and rear detectors) as can be seen in unsharp masking digital image processing, which subtracts Gaussian-blurred image from the original image.

  5. Accelerated magnetic resonance diffusion tensor imaging of the median nerve using simultaneous multi-slice echo planar imaging with blipped CAIPIRINHA

    Energy Technology Data Exchange (ETDEWEB)

    Filli, Lukas; Kenkel, David; Boss, Andreas; Manoliu, Andrei; Andreisek, Gustav; Runge, Val M.; Guggenberger, Roman [University Hospital of Zurich, University of Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Piccirelli, Marco [University Hospital of Zurich, Department of Neuroradiology, Zurich (Switzerland); Bhat, Himanshu [Siemens Medical Solutions USA Inc, Charlestown, MA (United States)

    2016-06-15

    To investigate the feasibility of MR diffusion tensor imaging (DTI) of the median nerve using simultaneous multi-slice echo planar imaging (EPI) with blipped CAIPIRINHA. After federal ethics board approval, MR imaging of the median nerves of eight healthy volunteers (mean age, 29.4 years; range, 25-32) was performed at 3 T using a 16-channel hand/wrist coil. An EPI sequence (b-value, 1,000 s/mm{sup 2}; 20 gradient directions) was acquired without acceleration as well as with twofold and threefold slice acceleration. Fractional anisotropy (FA), mean diffusivity (MD) and quality of nerve tractography (number of tracks, average track length, track homogeneity, anatomical accuracy) were compared between the acquisitions using multivariate ANOVA and the Kruskal-Wallis test. Acquisition time was 6:08 min for standard DTI, 3:38 min for twofold and 2:31 min for threefold acceleration. No differences were found regarding FA (standard DTI: 0.620 ± 0.058; twofold acceleration: 0.642 ± 0.058; threefold acceleration: 0.644 ± 0.061; p ≥ 0.217) and MD (standard DTI: 1.076 ± 0.080 mm{sup 2}/s; twofold acceleration: 1.016 ± 0.123 mm{sup 2}/s; threefold acceleration: 0.979 ± 0.153 mm{sup 2}/s; p ≥ 0.074). Twofold acceleration yielded similar tractography quality compared to standard DTI (p > 0.05). With threefold acceleration, however, average track length and track homogeneity decreased (p = 0.004-0.021). Accelerated DTI of the median nerve is feasible. Twofold acceleration yields similar results to standard DTI. (orig.)

  6. Functional imaging of submandibular glands: diffusion-weighted echo-planar MRI before and after stimulation; Diffusionsgewichtete MRT zur Funktionsdiagnostik der Glandula submandibularis

    Energy Technology Data Exchange (ETDEWEB)

    Arndt, C.; Cramer, M.C.; Weiss, F.; Kaul, M.G.; Adam, G.; Habermann, C.R. [Zentrum fuer Bildgebende Diagnostik und Intervention, Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum Hamburg-Eppendorf (Germany); Graessner, J. [Siemens Medical Solutions (Germany); Petersen, K. [Zentrum fuer Psychosoziale Medizin, Klinik und Poliklinik fuer Psychiatrie und Psychotherapie, Universitaetsklinikum Hamburg-Eppendorf (Germany); Reitmeier, F.; Jaehne, M. [Kopf und Hautzentrum, Klinik und Poliklinik fuer Hals-, Nasen- und Ohrenheilkunde, Universitaetsklinikum Hamburg Eppendorf (Germany)

    2006-09-15

    Purpose: To investigate the feasibility of diffusion-weighted (DWI) echo-planar imaging (EPI) to depict the submandibular glands and to measure different functional conditions. Materials and Methods: Twenty-seven healthy volunteers were examined. Diffusion weighted sequence was performed prior to stimulation. Exactly 30 seconds after a commercially available lemon juice was given orally, the diffusion weighted sequence was repeated. All examinations were performed by using a 1.5-T superconducting system with a 30 mT/m maximum gradient capability and maximum slew rate of 125 mT/m/sec (Magnetom Symphony, Siemens, Erlangen, Germany). The lower part of the circularly polarized (CP) head coil and a standard two-element CP neck array coil were used. The flexibility of the neck array coil allowed positioning the N1 element (upper part of the coil) right next to the submandibular gland. The axial diffusion-weighted EPI (echo planar imaging) sequence was performed using a matrix of 119 x 128, a field of view of 250 x 250 mm (pixel size 2.1 x 1.95 mm), a section thickness of 5 mm with an interslice gap of 1 mm. The b factors used were 0 sec/mm{sup 2}, 500 sec/mm{sup 2} and 1000 sec/mm{sup 2}. Apparent diffusion coefficient (ADC) maps were digitally transferred to MRIcro (Chris Rorden, University of Nottingham, Great Britain). After detecting the submandibular glands a region of interest (ROI) was placed manually exactly within the boarder of both submandibular glands, excluding the external carotid artery on ADC maps. These procedures were performed on all ADC slices the submandibular glands could be differentiated in before and after oral stimulation. For statistical comparison of results, a student's t-test was performed with an overall two-tailed significance level of p=0.05. Results: The visualization of the submandibular glands using the diffusion-weighted EPI sequence was possible in all of the 27 volunteers. Prior to oral stimulation an ADC of 1.31 x 10{sup -3

  7. Fast Detection of Airports on Remote Sensing Images with Single Shot MultiBox Detector

    Science.gov (United States)

    Xia, Fei; Li, HuiZhou

    2018-01-01

    This paper introduces a method for fast airport detection on remote sensing images (RSIs) using Single Shot MultiBox Detector (SSD). To our knowledge, this could be the first study which introduces an end-to-end detection model into airport detection on RSIs. Based on the common low-level features between natural images and RSIs, a convolution neural network trained on large amounts of natural images was transferred to tackle the airport detection problem with limited annotated data. To deal with the specific characteristics of RSIs, some related parameters in the SSD, such as the scales and layers, were modified for more accurate and rapider detection. The experiments show that the proposed method could achieve 83.5% Average Recall at 8 FPS on RSIs with the size of 1024*1024. In contrast to Faster R-CNN, an improvement on AP and speed could be obtained.

  8. Compressive sensing sectional imaging for single-shot in-line self-interference incoherent holography

    Science.gov (United States)

    Weng, Jiawen; Clark, David C.; Kim, Myung K.

    2016-05-01

    A numerical reconstruction method based on compressive sensing (CS) for self-interference incoherent digital holography (SIDH) is proposed to achieve sectional imaging by single-shot in-line self-interference incoherent hologram. The sensing operator is built up based on the physical mechanism of SIDH according to CS theory, and a recovery algorithm is employed for image restoration. Numerical simulation and experimental studies employing LEDs as discrete point-sources and resolution targets as extended sources are performed to demonstrate the feasibility and validity of the method. The intensity distribution and the axial resolution along the propagation direction of SIDH by angular spectrum method (ASM) and by CS are discussed. The analysis result shows that compared to ASM the reconstruction by CS can improve the axial resolution of SIDH, and achieve sectional imaging. The proposed method may be useful to 3D analysis of dynamic systems.

  9. Development of a single-shot-imaging thin film for an online Thomson parabola spectrometer

    International Nuclear Information System (INIS)

    Sakaki, H.; Fukuda, Y.; Nishiuchi, M.; Hori, T.; Yogo, A.; Jinno, S.; Kanasaki, M.; Niita, K.

    2013-01-01

    A single-shot-imaging thin scintillator film was developed for an online Thomson parabola (TP) spectrometer and the first analysis of laser accelerated ions, using the online TP spectrometer, was demonstrated at the JAEA-Kansai Advanced Relativistic Engineering Laser System (J-KAREN). An energy spectrum of ∼4.0 MeV protons is obtained using only this imaging film without the need of a microchannel plate that is typically utilized in online ion analyses. A general-purpose Monte Carlo particle and heavy ion-transport code system, which consists of various quantum dynamics models, was used for the prediction of the luminescent properties of the scintillator. The simulation can reasonably predict not only the ion trajectories detected by the spectrometer, but also luminescence properties.

  10. Echo-Planar Imaging Based J-Resolved Spectroscopic Imaging for Improved Metabolite Detection in Prostate Cancer

    Science.gov (United States)

    2012-10-01

    Clinical Setting" was presented at the 20th International Society of Magnetic Resonance in Medicine (ISMRM) meeting in Melbourne , Australia (May 5-11...experience. Eur Urol 2001;40(1):75–83. 5. Chandra RV, Heinze S, Dowling R, Shadbolt C, Costello A, Pedersen J. Endorectal mag- netic resonance imaging

  11. Echo-Planar Imaging-Based, J-Resolved Spectroscopic Imaging for Improved Metabolite Detection in Prostate Cancer

    Science.gov (United States)

    2016-12-01

    post-process the multi-dimensional MRS data from different prostate pathologies . Scope: Improved cancer detection (specificity) in differentiating...MATERIALS AND METHODS Patients Between March 2012 and May 2013, twenty-two patients with PCa with a mean age of 63.8 years (range, 46–79 years), who...tumor voxels, which was confirmed by the pathology report. After reconstruction, the EP-JRESI data were overlaid onto MRI images. MRI and MRSI A body

  12. Prior-knowledge Fitting of Accelerated Five-dimensional Echo Planar J-resolved Spectroscopic Imaging: Effect of Nonlinear Reconstruction on Quantitation.

    Science.gov (United States)

    Iqbal, Zohaib; Wilson, Neil E; Thomas, M Albert

    2017-07-24

    1 H Magnetic Resonance Spectroscopic imaging (SI) is a powerful tool capable of investigating metabolism in vivo from mul- tiple regions. However, SI techniques are time consuming, and are therefore difficult to implement clinically. By applying non-uniform sampling (NUS) and compressed sensing (CS) reconstruction, it is possible to accelerate these scans while re- taining key spectral information. One recently developed method that utilizes this type of acceleration is the five-dimensional echo planar J-resolved spectroscopic imaging (5D EP-JRESI) sequence, which is capable of obtaining two-dimensional (2D) spectra from three spatial dimensions. The prior-knowledge fitting (ProFit) algorithm is typically used to quantify 2D spectra in vivo, however the effects of NUS and CS reconstruction on the quantitation results are unknown. This study utilized a simulated brain phantom to investigate the errors introduced through the acceleration methods. Errors (normalized root mean square error >15%) were found between metabolite concentrations after twelve-fold acceleration for several low concentra- tion (OGM) human brain matter were quantified in vivo using the 5D EP-JRESI sequence with eight-fold acceleration.

  13. Comparison of gradient-recalled echo and spin-echo echo-planar imaging MR elastography in staging liver fibrosis. A meta-analysis

    International Nuclear Information System (INIS)

    Kim, Yong Seek; Jang, Yu Na; Song, Ji Soo

    2018-01-01

    To compare the diagnostic performance of gradient-recalled echo-based magnetic resonance elastography (GRE-MRE) and spin-echo echo-planar imaging-based MRE (SE-EPI-MRE) in liver fibrosis staging. A systematic literature search was performed to identify studies involving the performance of MRE for the diagnosis of liver fibrosis. Pooled sensitivity, specificity, positive and negative likelihood ratios, the diagnostic odds ratio, and a summary receiver operating characteristic (ROC) curve were estimated by using a bivariate random effects model. Subgroup analyses were performed between different study characteristics. Twenty-six studies with a total of 3,200 patients were included in the meta-analysis. Pooled sensitivity and specificity of GRE-MRE and SE-EPI-MRE did not differ significantly. The area under the summary ROC curve for stage diagnosis of any (F ≥ 1), significant (F ≥ 2), advanced (F ≥ 3), and cirrhosis (F = 4) on GRE-MRE and SE-EPI-MRE were 0.93 versus 0.94, 0.95 versus 0.94, 0.94 versus 0.95, and 0.92 versus 0.93, respectively. Substantial heterogeneity was detected for both sequences. Both GRE and SE-EPI-MRE show high sensitivity and specificity for detection of each stage of liver fibrosis, without significant differences. Magnetic resonance elastography (MRE) may be useful for noninvasive evaluation of liver fibrosis in chronic liver disease. (orig.)

  14. Single shot imaging through turbid medium and around corner using coherent light

    Science.gov (United States)

    Li, Guowei; Li, Dayan; Situ, Guohai

    2018-01-01

    Optical imaging through turbid media and around corner is a difficult challenge. Even a very thin layer of a turbid media, which randomly scatters the probe light, can appear opaque and hide any objects behind it. Despite many recent advances, no current method can image the object behind turbid media with single record using coherent laser illumination. Here we report a method that allows non-invasive single-shot optical imaging through turbid media and around corner via speckle correlation. Instead of being as an obstacle in forming diffractionlimited images, speckle actually can be a carrier that encodes sufficient information to imaging through visually opaque layers. Optical imaging through turbid media and around corner is experimentally demonstrated using traditional imaging system with the aid of iterative phase retrieval algorithm. Our method require neither scan of illumination nor two-arm interferometry or long-time exposure in acquisition, which has new implications in optical sensing through common obscurants such as fog, smoke and haze.

  15. BOLD contrast fMRI of whole rodent tumour during air or carbogen breathing using echo-planar imaging at 1.5 T

    International Nuclear Information System (INIS)

    Landuyt, W.; Bogaert, W. van den; Lambin, P.; Hermans, R.; Bosmans, H.; Sunaert, S.; Beatse, E.; Farina, D.; Meijerink, M.; Zhang, H.; Marchal, G.

    2001-01-01

    The aim of this study was to evaluate the feasibility of functional MR imaging (fMRI) at 1.5 T, exploiting blood oxygenation level-dependent (BOLD) contrast, for detecting changes in whole-tumour oxygenation induced by carbogen (5% CO 2 +95% O 2 ) inhalation of the host. Adult WAG/Rij rats with rhabdomyosarcomas growing subcutaneously in the lower flank were imaged when tumours reached sizes between 1 and 11 cm 3 (n=12). Air and carbogen were alternatively supplied at 2 l/min using a snout mask. Imaging was done on a 1.5-T MR scanner using a T2*-weighted gradient-echo, echo-planar imaging (GE-EPI) sequence. Analysis of the whole-tumour EPI images was based on statistical parametric maps. Voxels with and without signal intensity changes (SIC) were recorded. Significance thresholds were set at p<0.05, corrected for multiple comparisons. In continuous air breathing condition, 3 of 12 tumours showed significant negative SIC and 1 tumour had a clear-cut positive SIC. The remaining tumours showed very little or no change. When switching to carbogen breathing, the SIC were significantly positive in 10 of 12 tumours. Negative SIC were present in 4 tumours, of which three were simultaneously characterised by positive SIC. The overall analysis indicated that 6 of the 12 tumours could be considered as strong positive responders to carbogen. Our research demonstrates the applicability of fMRI GE-EPI at 1.5 T to study whole-tumour oxygenation non-invasively. The observed negative SIC during air condition may reflect the presence of transient hypoxia during these measurements. Selection of tumours on the basis of their individual response to carbogen is possible, indicating a role of such non-invasive measurements for using tailor-made treatments. (orig.)

  16. Accelerated magnetic resonance diffusion tensor imaging of the median nerve using simultaneous multi-slice echo planar imaging with blipped CAIPIRINHA.

    Science.gov (United States)

    Filli, Lukas; Piccirelli, Marco; Kenkel, David; Boss, Andreas; Manoliu, Andrei; Andreisek, Gustav; Bhat, Himanshu; Runge, Val M; Guggenberger, Roman

    2016-06-01

    To investigate the feasibility of MR diffusion tensor imaging (DTI) of the median nerve using simultaneous multi-slice echo planar imaging (EPI) with blipped CAIPIRINHA. After federal ethics board approval, MR imaging of the median nerves of eight healthy volunteers (mean age, 29.4 years; range, 25-32) was performed at 3 T using a 16-channel hand/wrist coil. An EPI sequence (b-value, 1,000 s/mm(2); 20 gradient directions) was acquired without acceleration as well as with twofold and threefold slice acceleration. Fractional anisotropy (FA), mean diffusivity (MD) and quality of nerve tractography (number of tracks, average track length, track homogeneity, anatomical accuracy) were compared between the acquisitions using multivariate ANOVA and the Kruskal-Wallis test. Acquisition time was 6:08 min for standard DTI, 3:38 min for twofold and 2:31 min for threefold acceleration. No differences were found regarding FA (standard DTI: 0.620 ± 0.058; twofold acceleration: 0.642 ± 0.058; threefold acceleration: 0.644 ± 0.061; p ≥ 0.217) and MD (standard DTI: 1.076 ± 0.080 mm(2)/s; twofold acceleration: 1.016 ± 0.123 mm(2)/s; threefold acceleration: 0.979 ± 0.153 mm(2)/s; p ≥ 0.074). Twofold acceleration yielded similar tractography quality compared to standard DTI (p > 0.05). With threefold acceleration, however, average track length and track homogeneity decreased (p = 0.004-0.021). Accelerated DTI of the median nerve is feasible. Twofold acceleration yields similar results to standard DTI. • Standard DTI of the median nerve is limited by its long acquisition time. • Simultaneous multi-slice acquisition is a new technique for accelerated DTI. • Accelerated DTI of the median nerve yields similar results to standard DTI.

  17. Self-Calibrating Wave-Encoded Variable-Density Single-Shot Fast Spin Echo Imaging.

    Science.gov (United States)

    Chen, Feiyu; Taviani, Valentina; Tamir, Jonathan I; Cheng, Joseph Y; Zhang, Tao; Song, Qiong; Hargreaves, Brian A; Pauly, John M; Vasanawala, Shreyas S

    2018-04-01

    It is highly desirable in clinical abdominal MR scans to accelerate single-shot fast spin echo (SSFSE) imaging and reduce blurring due to T 2 decay and partial-Fourier acquisition. To develop and investigate the clinical feasibility of wave-encoded variable-density SSFSE imaging for improved image quality and scan time reduction. Prospective controlled clinical trial. With Institutional Review Board approval and informed consent, the proposed method was assessed on 20 consecutive adult patients (10 male, 10 female, range, 24-84 years). A wave-encoded variable-density SSFSE sequence was developed for clinical 3.0T abdominal scans to enable high acceleration (3.5×) with full-Fourier acquisitions by: 1) introducing wave encoding with self-refocusing gradient waveforms to improve acquisition efficiency; 2) developing self-calibrated estimation of wave-encoding point-spread function and coil sensitivity to improve motion robustness; and 3) incorporating a parallel imaging and compressed sensing reconstruction to reconstruct highly accelerated datasets. Image quality was compared pairwise with standard Cartesian acquisition independently and blindly by two radiologists on a scale from -2 to 2 for noise, contrast, confidence, sharpness, and artifacts. The average ratio of scan time between these two approaches was also compared. A Wilcoxon signed-rank tests with a P value under 0.05 considered statistically significant. Wave-encoded variable-density SSFSE significantly reduced the perceived noise level and improved the sharpness of the abdominal wall and the kidneys compared with standard acquisition (mean scores 0.8, 1.2, and 0.8, respectively, P variable-density sampling SSFSE achieves improved image quality with clinically relevant echo time and reduced scan time, thus providing a fast and robust approach for clinical SSFSE imaging. 1 Technical Efficacy: Stage 6 J. Magn. Reson. Imaging 2018;47:954-966. © 2017 International Society for Magnetic Resonance in Medicine.

  18. Effect of Task-Correlated Physiological Fluctuations and Motion in 2D and 3D Echo-Planar Imaging in a Higher Cognitive Level fMRI Paradigm.

    Science.gov (United States)

    Ladstein, Jarle; Evensmoen, Hallvard R; Håberg, Asta K; Kristoffersen, Anders; Goa, Pål E

    2016-01-01

    To compare 2D and 3D echo-planar imaging (EPI) in a higher cognitive level fMRI paradigm. In particular, to study the link between the presence of task-correlated physiological fluctuations and motion and the fMRI contrast estimates from either 2D EPI or 3D EPI datasets, with and without adding nuisance regressors to the model. A signal model in the presence of partly task-correlated fluctuations is derived, and predictions for contrast estimates with and without nuisance regressors are made. Thirty-one healthy volunteers were scanned using 2D EPI and 3D EPI during a virtual environmental learning paradigm. In a subgroup of 7 subjects, heart rate and respiration were logged, and the correlation with the paradigm was evaluated. FMRI analysis was performed using models with and without nuisance regressors. Differences in the mean contrast estimates were investigated by analysis-of-variance using Subject, Sequence, Day, and Run as factors. The distributions of group level contrast estimates were compared. Partially task-correlated fluctuations in respiration, heart rate and motion were observed. Statistically significant differences were found in the mean contrast estimates between the 2D EPI and 3D EPI when using a model without nuisance regressors. The inclusion of nuisance regressors for cardiorespiratory effects and motion reduced the difference to a statistically non-significant level. Furthermore, the contrast estimate values shifted more when including nuisance regressors for 3D EPI compared to 2D EPI. The results are consistent with 3D EPI having a higher sensitivity to fluctuations compared to 2D EPI. In the presence partially task-correlated physiological fluctuations or motion, proper correction is necessary to get expectation correct contrast estimates when using 3D EPI. As such task-correlated physiological fluctuations or motion is difficult to avoid in paradigms exploring higher cognitive functions, 2D EPI seems to be the preferred choice for higher

  19. Assessment of cerebral blood flow reserve using blood oxygen level-dependent echo planar imaging after acetazolamide administration in patients post-STA-MCA anastomosis surgery

    International Nuclear Information System (INIS)

    Zenke, Kiichiro; Kusunoki, Katsusuke; Saito, Masahiro; Sadamoto, Kazuhiko; Ohta, Shinsuke; Kumon, Yoshiaki; Sakaki, Saburo; Nagasawa, Kiyoshi

    1998-01-01

    Recently, blood oxygen level-dependent (BOLD) echo planar imaging (EPI) has been used to estimate blood flow changes. Theoretically, a relative decrement of deoxyhemoglobin in cerebral blood supply induces a MR signal change after neuronal stimulation. In the present study, we have attempted to evaluate CBF reserve capacity by the BOLD EPI in patients who had undergone STA-MCA anastomosis surgery. Then, we compared with the signal intensity changes obtained by this procedure with the CBF changes by Xe-SPECT after acetazolamide administration. Six patients, post-STA-MCA anastomosis surgery, were studied. Pre-operatively, MR signal intensity and CBF, by Xe-SPECT, were increased in the intact side after acetazolamide administration in all patients, and MR signal intensities were decreased in low flow regions after acetazolamide administration in all four patients in whom so-called steal phenomenon was demonstrated by Xe-SPECT study. Post-operatively, poor response was shown after acetazolamide administration with both Xe-SPECT and BOLD EPI in the two patients who had unsuccessful anastomoses. In the successfully anastomosed patients, improved vascular reactivity was demonstrated on BOLD EPI after acetazolamide administration in 3 of 4 patients in whom an improvement of vascular reactivity was demonstrated on Xe-SPECT. In one patient, MRI studies were considered to have technical artifacts, because the MR signal intensity did not increase, even in the intact side after acetazolamide administration. In conclusion, BOLD EPI after acetazolamide administration is an useful procedure for the pre- and post-operative of vascular reserve in patients with ischemic stroke. (author)

  20. Utility of echo-planar gradient-echo T2*-weighted MR images in patients with primary intracerebral hemorrhage

    International Nuclear Information System (INIS)

    Yokoe, Toshio; Yoshida, Tazuka; Kobayashi, Nozomu; Nakamura, Yukihiro; Kubota, Kazuyuki

    2005-01-01

    Magnetic resonance imaging (MRI) has the potential to reveal residues of intracerabral hemorrhage (ICH) throughout life because of the high sensitivity for iron-containing compounds. Gradient-echo T2 * -weighted MR imaging (T2 * MRI) requiring short times for complete acquisition is known to detect small areas of signal loss without surrounding edema representing microbleeds (MBs). MBs in the basal ganglia including the thalami are suggested to be closely related to intracerebral atherosclerotic microangiopathy. We looked for more than 3 MBs in basal ganglia or thalamus of patients with and without episodes of previous ICH. Twelve patients with previous hemorrhagic stroke and 82 without were studied. Multiple MBs in those regions were significantly more frequent in patients with recurrent ICH. In addition, a 76-year-old woman with a history of hypertension was transferred to our hospital for treatment of head injury. She had multiple incidental old basal ganglionic and thalamic MBs. The patient had an asymptomatic primary ICH on computed tomography (CT) 3 months later. In conclusion, MR evidence of multiple MBs in the basal ganglia and thalamus might identify patients at a risk for new and recurrent ICH. Therefore, patients with multiple MBs in those regions should be treated for cerebrovascular risk factors, especially hypertension. Our results appear to confirm the utility of T2 * MRI in hemorrhagic stroke. (author)

  1. Multi-slice echo-planar spectroscopic MR imaging provides both global and local metabolite measures in multiple sclerosis

    DEFF Research Database (Denmark)

    Mathiesen, Henrik Kahr; Tscherning, Thomas; Sorensen, Per Soelberg

    2005-01-01

    MR spectroscopy (MRS) provides information about neuronal loss or dysfunction by measuring decreases in N-acetyl aspartate (NAA), a metabolite widely believed to be a marker of neuronal viability. In multiple sclerosis (MS), whole-brain NAA (WBNAA) has been suggested as a marker of disease...... progression and treatment efficacy in treatment trials, and the ability to measure NAA loss in specific brain regions early in the evolution of this disease may have prognostic value. Most spectroscopic studies to date have been limited to single voxels or nonlocalized measurements of WBNAA only......, measurements of metabolites in specific brain areas chosen after image acquisition (e.g., normal-appearing white matter (NAWM), gray matter (GM), and lesions) can be obtained. The identification and exclusion of regions that are inadequate for spectroscopic evaluation in global assessments can significantly...

  2. Single-Shot, Volumetrically Illuminated, Three-Dimensional, Tomographic Laser-Induced-Fluorescence Imaging in a Gaseous Free Jet

    Science.gov (United States)

    2016-04-28

    Single-shot, volumetrically illuminated, three- dimensional, tomographic laser-induced- fluorescence imaging in a gaseous free jet Benjamin R. Halls...acquisition; (110.6955) Tomographic imaging ; (110.6960) Tomography; (280.2490) Flow diagnostics; (300.2530) Fluorescence , laser-induced...84 (1983). 2. I. van Cruyningen, A. Lozano, and R. K. Hanson, “Quantitative imaging of concentration by planar laser-induced fluorescence ,” Exp

  3. In vivo single-shot (13)C spectroscopic imaging of hyperpolarized metabolites by spatiotemporal encoding

    DEFF Research Database (Denmark)

    Schmidt, Rita; Laustsen, Christoffer; Dumez, Jean-Nicolas

    2014-01-01

    are necessary. Several approaches have been customized for hyperpolarized (13)C MRI, including CSI with a center-out k-space encoding, EPSI, and spectrally selective pulses in combination with spiral EPI acquisitions. Recent studies have described the potential of single-shot alternatives based...... temporal) data sets were obtained at 7T from a murine lymphoma tumor model....

  4. Pilot Assessment of Brain Metabolism in Perinatally HIV-Infected Youths Using Accelerated 5D Echo Planar J-Resolved Spectroscopic Imaging.

    Science.gov (United States)

    Iqbal, Zohaib; Wilson, Neil E; Keller, Margaret A; Michalik, David E; Church, Joseph A; Nielsen-Saines, Karin; Deville, Jaime; Souza, Raissa; Brecht, Mary-Lynn; Thomas, M Albert

    2016-01-01

    To measure cerebral metabolite levels in perinatally HIV-infected youths and healthy controls using the accelerated five dimensional (5D) echo planar J-resolved spectroscopic imaging (EP-JRESI) sequence, which is capable of obtaining two dimensional (2D) J-resolved spectra from three spatial dimensions (3D). After acquisition and reconstruction of the 5D EP-JRESI data, T1-weighted MRIs were used to classify brain regions of interest for HIV patients and healthy controls: right frontal white (FW), medial frontal gray (FG), right basal ganglia (BG), right occipital white (OW), and medial occipital gray (OG). From these locations, respective J-resolved and TE-averaged spectra were extracted and fit using two different quantitation methods. The J-resolved spectra were fit using prior knowledge fitting (ProFit) while the TE-averaged spectra were fit using the advanced method for accurate robust and efficient spectral fitting (AMARES). Quantitation of the 5D EP-JRESI data using the ProFit algorithm yielded significant metabolic differences in two spatial locations of the perinatally HIV-infected youths compared to controls: elevated NAA/(Cr+Ch) in the FW and elevated Asp/(Cr+Ch) in the BG. Using the TE-averaged data quantified by AMARES, an increase of Glu/(Cr+Ch) was shown in the FW region. A strong negative correlation (r 0.6) were shown between Asp/(Cr+Ch) and CD4 counts in the FG and BG. The complimentary results using ProFit fitting of J-resolved spectra and AMARES fitting of TE-averaged spectra, which are a subset of the 5D EP-JRESI acquisition, demonstrate an abnormal energy metabolism in the brains of perinatally HIV-infected youths. This may be a result of the HIV pathology and long-term combinational anti-retroviral therapy (cART). Further studies of larger perinatally HIV-infected cohorts are necessary to confirm these findings.

  5. Femtosecond Single-Shot Imaging of Nanoscale Ferromagnetic Order in Co/Pd Multilayers using Resonant X-ray Holography

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Tianhan; Zhu, Diling; Benny Wu,; Graves, Catherine; Schaffert, Stefan; Rander, Torbjorn; Muller, leonard; Vodungbo, Boris; Baumier, Cedric; Bernstein, David P.; Brauer, Bjorn; Cros, Vincent; Jong, Sanne de; Delaunay, Renaud; Fognini, Andreas; Kukreja, Roopali; Lee, Sooheyong; Lopez-Flores, Victor; Mohanty, Jyoti; Pfau, Bastian; Popescu, 5 Horia

    2012-05-15

    We present the first single-shot images of ferromagnetic, nanoscale spin order taken with femtosecond x-ray pulses. X-ray-induced electron and spin dynamics can be outrun with pulses shorter than 80 fs in the investigated fluence regime, and no permanent aftereffects in the samples are observed below a fluence of 25 mJ/cm{sup 2}. Employing resonant spatially-muliplexed x-ray holography results in a low imaging threshold of 5 mJ/cm{sup 2}. Our results open new ways to combine ultrafast laser spectroscopy with sequential snapshot imaging on a single sample, generating a movie of excited state dynamics.

  6. Single-shot imaging with higher-dimensional encoding using magnetic field monitoring and concomitant field correction.

    Science.gov (United States)

    Testud, Frederik; Gallichan, Daniel; Layton, Kelvin J; Barmet, Christoph; Welz, Anna M; Dewdney, Andrew; Cocosco, Chris A; Pruessmann, Klaas P; Hennig, Jürgen; Zaitsev, Maxim

    2015-03-01

    PatLoc (Parallel Imaging Technique using Localized Gradients) accelerates imaging and introduces a resolution variation across the field-of-view. Higher-dimensional encoding employs more spatial encoding magnetic fields (SEMs) than the corresponding image dimensionality requires, e.g. by applying two quadratic and two linear spatial encoding magnetic fields to reconstruct a 2D image. Images acquired with higher-dimensional single-shot trajectories can exhibit strong artifacts and geometric distortions. In this work, the source of these artifacts is analyzed and a reliable correction strategy is derived. A dynamic field camera was built for encoding field calibration. Concomitant fields of linear and nonlinear spatial encoding magnetic fields were analyzed. A combined basis consisting of spherical harmonics and concomitant terms was proposed and used for encoding field calibration and image reconstruction. A good agreement between the analytical solution for the concomitant fields and the magnetic field simulations of the custom-built PatLoc SEM coil was observed. Substantial image quality improvements were obtained using a dynamic field camera for encoding field calibration combined with the proposed combined basis. The importance of trajectory calibration for single-shot higher-dimensional encoding is demonstrated using the combined basis including spherical harmonics and concomitant terms, which treats the concomitant fields as an integral part of the encoding. © 2014 Wiley Periodicals, Inc.

  7. Single shot trajectory design for region-specific imaging using linear and nonlinear magnetic encoding fields.

    Science.gov (United States)

    Layton, Kelvin J; Gallichan, Daniel; Testud, Frederik; Cocosco, Chris A; Welz, Anna M; Barmet, Christoph; Pruessmann, Klaas P; Hennig, Jürgen; Zaitsev, Maxim

    2013-09-01

    It has recently been demonstrated that nonlinear encoding fields result in a spatially varying resolution. This work develops an automated procedure to design single-shot trajectories that create a local resolution improvement in a region of interest. The technique is based on the design of optimized local k-space trajectories and can be applied to arbitrary hardware configurations that employ any number of linear and nonlinear encoding fields. The trajectories designed in this work are tested with the currently available hardware setup consisting of three standard linear gradients and two quadrupolar encoding fields generated from a custom-built gradient insert. A field camera is used to measure the actual encoding trajectories up to third-order terms, enabling accurate reconstructions of these demanding single-shot trajectories, although the eddy current and concomitant field terms of the gradient insert have not been completely characterized. The local resolution improvement is demonstrated in phantom and in vivo experiments. Copyright © 2012 Wiley Periodicals, Inc.

  8. Development and Characterization of Two-Dimensional Gratings for Single-Shot X-ray Phase-Contrast Imaging

    Directory of Open Access Journals (Sweden)

    Margarita Zakharova

    2018-03-01

    Full Text Available Single-shot grating-based phase-contrast imaging techniques offer additional contrast modalities based on the refraction and scattering of X-rays in a robust and versatile configuration. The utilization of a single optical element is possible in such methods, allowing the shortening of the acquisition time and increasing flux efficiency. One of the ways to upgrade single-shot imaging techniques is to utilize customized optical components, such as two-dimensional (2D X-ray gratings. In this contribution, we present the achievements in the development of 2D gratings with UV lithography and gold electroplating. Absorption gratings represented by periodic free-standing gold pillars with lateral structure sizes from 5 µm to 25 µm and heights from 5 µm to 28 µm have shown a high degree of periodicity and defect-free patterns. Grating performance was tested in a radiographic setup using a self-developed quality assessment algorithm based on the intensity distribution histograms. The algorithm allows the final user to estimate the suitability of a specific grating to be used in a particular setup.

  9. Frequency-Domain Tomography for Single-shot, Ultrafast Imaging of Evolving Laser-Plasma Accelerators

    Science.gov (United States)

    Li, Zhengyan; Zgadzaj, Rafal; Wang, Xiaoming; Downer, Michael

    2011-10-01

    Intense laser pulses propagating through plasma create plasma wakefields that often evolve significantly, e.g. by expanding and contracting. However, such dynamics are known in detail only through intensive simulations. Laboratory visualization of evolving plasma wakes in the ``bubble'' regime is important for optimizing and scaling laser-plasma accelerators. Recently snap-shots of quasi-static wakes were recorded using frequency-domain holography (FDH). To visualize the wake's evolution, we have generalized FDH to frequency-domain tomography (FDT), which uses multiple probes propagating at different angles with respect to the pump pulse. Each probe records a phase streak, imprinting a partial record of the evolution of pump-created structures. We then topographically reconstruct the full evolution from all phase streaks. To prove the concept, a prototype experiment visualizing nonlinear index evolution in glass is demonstrated. Four probes propagating at 0, 0.6, 2, 14 degrees to the index ``bubble'' are angularly and temporally multiplexed to a single spectrometer to achieve cost-effective FDT. From these four phase streaks, an FDT algorithm analogous to conventional CT yields a single-shot movie of the pump's self-focusing dynamics.

  10. Single-shot full resolution region-of-interest (ROI) reconstruction in image plane digital holographic microscopy

    Science.gov (United States)

    Singh, Mandeep; Khare, Kedar

    2018-05-01

    We describe a numerical processing technique that allows single-shot region-of-interest (ROI) reconstruction in image plane digital holographic microscopy with full pixel resolution. The ROI reconstruction is modelled as an optimization problem where the cost function to be minimized consists of an L2-norm squared data fitting term and a modified Huber penalty term that are minimized alternately in an adaptive fashion. The technique can provide full pixel resolution complex-valued images of the selected ROI which is not possible to achieve with the commonly used Fourier transform method. The technique can facilitate holographic reconstruction of individual cells of interest from a large field-of-view digital holographic microscopy data. The complementary phase information in addition to the usual absorption information already available in the form of bright field microscopy can make the methodology attractive to the biomedical user community.

  11. Clinical application of Half Fourier Acquisition Single Shot Turbo Spin Echo (HASTE) imaging accelerated by simultaneous multi-slice acquisition.

    Science.gov (United States)

    Schulz, Jenni; P Marques, José; Ter Telgte, Annemieke; van Dorst, Anouk; de Leeuw, Frank-Erik; Meijer, Frederick J A; Norris, David G

    2018-01-01

    As a single-shot sequence with a long train of refocusing pulses, Half-Fourier Acquisition Single-Shot Turbo-Spin-Echo (HASTE) suffers from high power deposition limiting use at high resolutions and high field strengths, particularly if combined with acceleration techniques such as simultaneous multi-slice (SMS) imaging. Using a combination of multiband (MB)-excitation and PINS-refocusing pulses will effectively accelerate the acquisition time while staying within the SAR limitations. In particular, uncooperative and young patients will profit from the speed of the MB-PINS HASTE sequence, as clinical diagnosis can be possible without sedation. Materials and MethodsMB-excitation and PINS-refocusing pulses were incorporated into a HASTE-sequence with blipped CAIPIRINHA and TRAPS including an internal FLASH reference scan for online reconstruction. Whole brain MB-PINS HASTE data were acquired on a Siemens 3T-Prisma system from 10 individuals and compared to a clinical HASTE protocol. ResultsThe proposed MB-PINS HASTE protocol accelerates the acquisition by about a factor 2 compared to the clinical HASTE. The diagnostic image quality proved to be comparable for both sequences for the evaluation of the overall aspect of the brain, the detection of white matter changes and areas of tissue loss, and for the evaluation of the CSF spaces although artifacts were more frequently encountered with MB-PINS HASTE. ConclusionsMB-PINS HASTE enables acquisition of slice accelerated highly T2-weighted images and provides good diagnostic image quality while reducing acquisition time. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Comparison of Diffusion-Weighted Imaging in the Human Brain Using Readout-Segmented EPI and PROPELLER Turbo Spin Echo With Single-Shot EPI at 7 T MRI.

    Science.gov (United States)

    Kida, Ikuhiro; Ueguchi, Takashi; Matsuoka, Yuichiro; Zhou, Kun; Stemmer, Alto; Porter, David

    2016-07-01

    The purpose of the present study was to compare periodically rotated overlapping parallel lines with enhanced reconstruction-type turbo spin echo diffusion-weighted imaging (pTSE-DWI) and readout-segmented echo planar imaging (rsEPI-DWI) with single-shot echo planar imaging (ssEPI-DWI) in a 7 T human MR system. We evaluated the signal-to-noise ratio (SNR), image distortion, and apparent diffusion coefficient values in the human brain. Six healthy volunteers were included in this study. The study protocol was approved by our institutional review board. All measurements were performed at 7 T using pTSE-DWI, rsEPI-DWI, and ssEPI-DWI sequences. The spatial resolution was 1.2 × 1.2 mm in-plane with a 3-mm slice thickness. Signal-to-noise ratio was measured using 2 scans. The ssEPI-DWI sequence showed significant image blurring, whereas pTSE-DWI and rsEPI-DWI sequences demonstrated high image quality with low geometrical distortion compared with reference T2-weighted, turbo spin echo images. Signal loss in ventral regions near the air-filled paranasal sinus/nasal cavity was found in ssEPI-DWI and rsEPI-DWI but not pTSE-DWI. The apparent diffusion coefficient values for ssEPI-DWI were 824 ± 17 × 10 and 749 ± 25 × 10 mm/s in the gray matter and white matter, respectively; the values obtained for pTSE-DWI were 798 ± 21 × 10 and 865 ± 40 × 10 mm/s; and the values obtained for rsEPI-DWI were 730 ± 12 × 10 and 722 ± 25 × 10 mm/s. The pTSE-DWI images showed no additional distortion comparison to the T2-weighted images, but had a lower SNR than ssEPI-DWI and rsEPI-DWI. The rsEPI-DWI sequence provided high-quality images with minor distortion and a similar SNR to ssEPI-DWI. Our results suggest that the benefits of the rsEPI-DWI and pTSE-DWI sequences, in terms of SNR, image quality, and image distortion, appear to outweigh those of ssEPI-DWI. Thus, pTSE-DWI and rsEPI-DWI at 7 T have great potential use for clinical diagnoses. However, it is noteworthy that both

  13. Direct magnetic field estimation based on echo planar raw data.

    Science.gov (United States)

    Testud, Frederik; Splitthoff, Daniel Nicolas; Speck, Oliver; Hennig, Jürgen; Zaitsev, Maxim

    2010-07-01

    Gradient recalled echo echo planar imaging is widely used in functional magnetic resonance imaging. The fast data acquisition is, however, very sensitive to field inhomogeneities which manifest themselves as artifacts in the images. Typically used correction methods have the common deficit that the data for the correction are acquired only once at the beginning of the experiment, assuming the field inhomogeneity distribution B(0) does not change over the course of the experiment. In this paper, methods to extract the magnetic field distribution from the acquired k-space data or from the reconstructed phase image of a gradient echo planar sequence are compared and extended. A common derivation for the presented approaches provides a solid theoretical basis, enables a fair comparison and demonstrates the equivalence of the k-space and the image phase based approaches. The image phase analysis is extended here to calculate the local gradient in the readout direction and improvements are introduced to the echo shift analysis, referred to here as "k-space filtering analysis." The described methods are compared to experimentally acquired B(0) maps in phantoms and in vivo. The k-space filtering analysis presented in this work demonstrated to be the most sensitive method to detect field inhomogeneities.

  14. MR imaging of the gastrointestinal tract with half-fourier single-shot fast spin echo (SSFSE)

    International Nuclear Information System (INIS)

    Boku, Houjun; Takehara, Yasuo; Isoda, Haruo; Isogai, Satoshi; Kaneko, Masao

    1999-01-01

    Our objective was to implement a non-invasive magnetic resonance imaging (MRI) technique combined with concentrated milk ingestion for depicting the gastrointestinal (GI) tract and detecting gastrointestinal motility and transit. The half-Fourier SSFSE (single-shot fast spin echo) sequence was optimized on the basis of a phantom study. In order to determine the feasibility of milk ingestion as a substitute for contrast medium, ten human volunteers were examined with SSFSE after two types of liquid ingestion (i.e., milk and water). The snapshot images provided subsecond data acquisition for each coronal plane, allowing visualization of peristalsis in the gastrointestinal tract in an almost real-time fashion, without motion-related image degradation, as would normally be seen using conventional MRI. There was no significant difference between concentrated milk and water in terms of depiction of the upper gastrointestinal tract; however, 10 min and 30 min after ingestion, concentrated milk showed better delineation of the intestine than that observed after water ingestion (p<0.01). MR gastrointestinal imaging is a non-invasive method that allows gastrointestinal depiction as well as analysis of motility and passage. Especially with concentrated milk ingestion, the distal intestines were well depicted with adequate contrast filling and distention. (author)

  15. Single-shot T2 mapping using overlapping-echo detachment planar imaging and a deep convolutional neural network.

    Science.gov (United States)

    Cai, Congbo; Wang, Chao; Zeng, Yiqing; Cai, Shuhui; Liang, Dong; Wu, Yawen; Chen, Zhong; Ding, Xinghao; Zhong, Jianhui

    2018-04-24

    An end-to-end deep convolutional neural network (CNN) based on deep residual network (ResNet) was proposed to efficiently reconstruct reliable T 2 mapping from single-shot overlapping-echo detachment (OLED) planar imaging. The training dataset was obtained from simulations that were carried out on SPROM (Simulation with PRoduct Operator Matrix) software developed by our group. The relationship between the original OLED image containing two echo signals and the corresponding T 2 mapping was learned by ResNet training. After the ResNet was trained, it was applied to reconstruct the T 2 mapping from simulation and in vivo human brain data. Although the ResNet was trained entirely on simulated data, the trained network was generalized well to real human brain data. The results from simulation and in vivo human brain experiments show that the proposed method significantly outperforms the echo-detachment-based method. Reliable T 2 mapping with higher accuracy is achieved within 30 ms after the network has been trained, while the echo-detachment-based OLED reconstruction method took approximately 2 min. The proposed method will facilitate real-time dynamic and quantitative MR imaging via OLED sequence, and deep convolutional neural network has the potential to reconstruct maps from complex MRI sequences efficiently. © 2018 International Society for Magnetic Resonance in Medicine.

  16. Utility of single shot fast spin echo technique in evaluating pancreaticobiliary diseases: T2-weighted image and magnetic resonance cholangiopancreatography

    International Nuclear Information System (INIS)

    Choi, Byoung Wook; Kim, Myeong Jin; Chung, Jae Bok; Ko, Heung Kyu; Kim, Dong Joon; Kim, Joo Hee; Chung, Jae Joon; Yoo, Hyung Sik; Lee, Jong Tae

    1999-01-01

    To evaluate the accuracy of T2-weighted imaging an MR cholangiopancreatography using the single shot fast spin-echo technique for evaluating pancreaticobiliary disease. Between March and July 1997, axial and coronal T2-weighted images(TE: 80-200 msec) and MR cholangiopancreatograms (TE: 800-1200 msec) were obtained in two ways [single slab (thickness: 30-50 mm) and multislice acquisition under chemical fat saturation] using SSFSE pulse sequencing in 131 cases of suspected pancreati-cobiliary disease. The accuracy of SSFSE MR imaging was assessed in 89 lesions of 74 patients [male, 48; female, 26; age range, 30-86 (mean, 59) years] confirmed surgicopathologically (50 lesions in 39 patients) and clinically (39 lesions in 35 patients). Two radiologists reviewed the MR images and diagnosis was determined by consensus. Correct diagnosis was confirmed in 84 of 89 lesions (94%). Seven lesions were falsely interpreted, false positive and false negative results accounting for two and five cases, respectively. Two pancreatic cancers were misdiagnosed as pancreatitis and a cancer of the proximal common bile duct(CBD) was interpreted as a distal CBD cancer. The sensitivity of SSFSE MR imaging for malignancy was 93 %. One CBD stone revealed by endoscopic retrograde cholangiopancreatography (ERCP) was not detected on MR images. In contrast, a stone in the CBD seen on MR images was not apparent on subsequent ERCP. Sensitivity and specificity for calculous disease were 96% and 99.7%, respectively. A benign stricture of the ampulla of Vater was falsely interpreted as normal, and correct diagnosis was possible in two falsely diagnosed cases when MR images were reviewed retrospectively. The combination of T2-weighted and cholangiographic images using SSFSE is an accurate method for diagnosing pancreatcobiliary diseases

  17. Clinical methods for single-shot instant MR imaging of the heart

    International Nuclear Information System (INIS)

    Cohen, M.S.; Weisskoff, R.; Rzedzian, R.

    1989-01-01

    The authors have compared cardiac protocols for instant MR methods that acquire complete images in 32 msec. Four protocols are compared: continuous scanning at a fixed TR with retrospective reordering; pseudogating by using a TR 50 msec greater than the R-R interval; progressive time delay (PTD), in which the delay from the R wave is electronically advanced; and real-time (RT) imaging at 16 images/sec, which enabled complete movies to be obtained in a single heartbeat. Spin-echo techniques have been used for the first three protocols; the RT method used gradient echoes

  18. Ultrafast Holographic Image Recording by Single Shot Femtosecond Spectral Hole Burning

    National Research Council Canada - National Science Library

    Rebane, Aleksander

    2001-01-01

    .... This allowed us to record image holograms with 150-fs duration pulses without need to accumulate the SHB effect from many exposures. Results of this research show that it is possible to perform optical recording of data in frequency-domain on ultrafast time scale. These results can be used also as a new diagnostic tool for femtosecond dynamics in various ultrafast optical interactions.

  19. A Shack-Hartmann Sensor for Single-Shot Multi-Contrast Imaging with Hard X-rays

    Directory of Open Access Journals (Sweden)

    Tomy dos Santos Rolo

    2018-05-01

    Full Text Available An array of compound refractive X-ray lenses (CRL with 20 × 20 lenslets, a focal distance of 20cm and a visibility of 0.93 is presented. It can be used as a Shack-Hartmann sensor for hard X-rays (SHARX for wavefront sensing and permits for true single-shot multi-contrast imaging the dynamics of materials with a spatial resolution in the micrometer range, sensitivity on nanosized structures and temporal resolution on the microsecond scale. The object’s absorption and its induced wavefront shift can be assessed simultaneously together with information from diffraction channels. In contrast to the established Hartmann sensors the SHARX has an increased flux efficiency through focusing of the beam rather than blocking parts of it. We investigated the spatiotemporal behavior of a cavitation bubble induced by laser pulses. Furthermore, we validated the SHARX by measuring refraction angles of a single diamond CRL, where we obtained an angular resolution better than 4 μ rad.

  20. Non-contrast-enhanced imaging of haemodialysis fistulas using quiescent-interval single-shot (QISS) MRA: a feasibility study

    International Nuclear Information System (INIS)

    Okur, A.; Kantarci, M.; Karaca, L.; Yildiz, S.; Sade, R.; Pirimoglu, B.; Keles, M.; Avci, A.; Çankaya, E.; Schmitt, P.

    2016-01-01

    Aim: To assess the efficiency of a novel quiescent-interval single-shot (QISS) technique for non-contrast-enhanced magnetic resonance angiography (MRA) of haemodialysis fistulas. Materials and methods: QISS MRA and colour Doppler ultrasound (CDU) images were obtained from 22 haemodialysis patients with end-stage renal disease (ESRD). A radiologist with extensive experience in vascular imaging initially assessed the fistulas using CDU. Two observers analysed each QISS MRA data set in terms of image quality, using a five-point scale ranging from 0 (non-diagnostic) to 4 (excellent), and lumen diameters of all segments were measured. Results: One hundred vascular segments were analysed for QISS MRA. Two anastomosis segments were considered non-diagnostic. None of the arterial or venous segments were evaluated as non-diagnostic. The image quality was poorer for the anastomosis level compared to the other segments (p<0.001 for arterial segments, and p<0.05 for venous segments), while no significant difference was determined for other vascular segments. Conclusion: QISS MRA has the potential to provide valuable complementary information to CDU regarding the imaging of haemodialysis fistulas. In addition, QISS non-enhanced MRA represents an alternative for assessment of haemodialysis fistulas, in which the administration of iodinated or gadolinium-based contrast agents is contraindicated. - Highlights: • Close monitoring and early intervention in hemodialysis fistulas may prolong longevity fistulas. • DopplerUS, contrast enhanced CT and MRI are using assessment of hemodialysis fistulas. • QISS nonenhanced MR angiography represents an alternative for assessment of hemodialysis fistulas.

  1. Multimodal MRI in the characterization of glial neoplasms: the combined role of single-voxel MR spectroscopy, diffusion imaging and echo-planar perfusion imaging

    International Nuclear Information System (INIS)

    Zonari, Paolo; Baraldi, Patrizia; Crisi, Girolamo

    2007-01-01

    Diffusion-weighted imaging (DWI), perfusion-weighted imaging (PWI) and MR spectroscopy (MRS) provide useful data for tumor evaluation. To assess the contribution of these multimodal techniques in grading glial neoplasms, we compared the value of DWI, PWI and MRS in the evaluation of histologically proven high- and low-grade gliomas in a population of 105 patients. Independently for each modality, the following variables were used to compare the tumors: minimum apparent diffusion coefficient (ADC) and maximum relative cerebral blood volume (rCBV) normalized values between tumor and healthy tissue, maximum Cho/Cr ratio and minimum NAA/Cr ratio in tumor, and scored lactate and lipid values in tumor. The Mann-Whitney and Wilcoxon tests were employed to compare DWI, PWI and MRS between tumor types. Logistic regression analysis was used to determine which parameters best increased the diagnostic accuracy in terms of sensitivity, specificity, and positive and negative predictive values. ROC curves were determined for parameters with high sensitivity and specificity to identify threshold values to separate high- from low-grade lesions. Statistically significant differences were found for rCBV tumor/normal tissue ratio, and NAA/Cr ratio in tumor and Cho/Cr ratio in tumor between low- and high-grade tumors. The best performing single parameter for group classification was the normalized rCBV value; including all parameters, statistical significance was reached by rCBV tumor/normal tissue ratio, NAA/Cr tumor ratio and lactate. From the ROC curves, a high probability for a neoplasm to be a high-grade lesion was associated with a rCBV tumor/normal tissue ratio of >1.16 and NAA/Cr tumor ratio of <0.44. Combining PWI and MRS with conventional MR imaging increases the accuracy of the attribution of malignancy to glial neoplasms. The best performing parameter was found to be the perfusion level. (orig.)

  2. Simultaneous multi-slice echo planar diffusion weighted imaging of the liver and the pancreas: Optimization of signal-to-noise ratio and acquisition time and application to intravoxel incoherent motion analysis

    Energy Technology Data Exchange (ETDEWEB)

    Boss, Andreas, E-mail: andreas.boss@usz.ch [Institute of Diagnostic and Interventional Radiology, University Hospital Zurich (Switzerland); Barth, Borna; Filli, Lukas; Kenkel, David; Wurnig, Moritz C. [Institute of Diagnostic and Interventional Radiology, University Hospital Zurich (Switzerland); Piccirelli, Marco [Institute of Neuroradiology, University Hospital of Zurich (Switzerland); Reiner, Caecilia S. [Institute of Diagnostic and Interventional Radiology, University Hospital Zurich (Switzerland)

    2016-11-15

    Purpose: To optimize and test a diffusion-weighted imaging (DWI) echo-planar imaging (EPI) sequence with simultaneous multi-slice (SMS) excitation in the liver and pancreas regarding acquisition time (TA), number of slices, signal-to-noise ratio (SNR), image quality (IQ), apparent diffusion coefficient (ADC) quantitation accuracy, and feasibility of intravoxel incoherent motion (IVIM) analysis. Materials and methods: Ten healthy volunteers underwent DWI of the upper abdomen at 3T. A SMS DWI sequence with CAIPIRINHA unaliasing technique (acceleration factors 2/3, denoted AF2/3) was compared to standard DWI-EPI (AF1). Four schemes were evaluated: (i) reducing TA, (ii) keeping TA identical with increasing number of averages, (iii) increasing number of slices with identical TA (iv) increasing number of b-values for IVIM. Acquisition schemes i-iii were evaluated qualitatively (reader score) and quantitatively (ADC values, SNR). Results: In scheme (i) no differences in SNR were observed (p = 0.321 − 0.038) with reduced TA (AF2 increase in SNR/time 75.6%, AF3 increase SNR/time 102.4%). No SNR improvement was obtained in scheme (ii). Increased SNR/time could be invested in acquisition of more and thinner slices or higher number of b-values. Image quality scores were stable for AF2 but decreased for AF3. Only for AF3, liver ADC values were systematically lower. Conclusion: SMS-DWI of the liver and pancreas provides substantially higher SNR/time, which either may be used for shorter scan time, higher slice resolution or IVIM measurements.

  3. Simultaneous multi-slice echo planar diffusion weighted imaging of the liver and the pancreas: Optimization of signal-to-noise ratio and acquisition time and application to intravoxel incoherent motion analysis

    International Nuclear Information System (INIS)

    Boss, Andreas; Barth, Borna; Filli, Lukas; Kenkel, David; Wurnig, Moritz C.; Piccirelli, Marco; Reiner, Caecilia S.

    2016-01-01

    Purpose: To optimize and test a diffusion-weighted imaging (DWI) echo-planar imaging (EPI) sequence with simultaneous multi-slice (SMS) excitation in the liver and pancreas regarding acquisition time (TA), number of slices, signal-to-noise ratio (SNR), image quality (IQ), apparent diffusion coefficient (ADC) quantitation accuracy, and feasibility of intravoxel incoherent motion (IVIM) analysis. Materials and methods: Ten healthy volunteers underwent DWI of the upper abdomen at 3T. A SMS DWI sequence with CAIPIRINHA unaliasing technique (acceleration factors 2/3, denoted AF2/3) was compared to standard DWI-EPI (AF1). Four schemes were evaluated: (i) reducing TA, (ii) keeping TA identical with increasing number of averages, (iii) increasing number of slices with identical TA (iv) increasing number of b-values for IVIM. Acquisition schemes i-iii were evaluated qualitatively (reader score) and quantitatively (ADC values, SNR). Results: In scheme (i) no differences in SNR were observed (p = 0.321 − 0.038) with reduced TA (AF2 increase in SNR/time 75.6%, AF3 increase SNR/time 102.4%). No SNR improvement was obtained in scheme (ii). Increased SNR/time could be invested in acquisition of more and thinner slices or higher number of b-values. Image quality scores were stable for AF2 but decreased for AF3. Only for AF3, liver ADC values were systematically lower. Conclusion: SMS-DWI of the liver and pancreas provides substantially higher SNR/time, which either may be used for shorter scan time, higher slice resolution or IVIM measurements.

  4. Turbo-Proton Echo Planar Spectroscopic Imaging (t-PEPSI) MR technique in the detection of diffuse axonal damage in brain injury. Comparison with Gradient-Recalled Echo (GRE) sequence.

    Science.gov (United States)

    Giugni, E; Sabatini, U; Hagberg, G E; Formisano, R; Castriota-Scanderbeg, A

    2005-01-01

    Diffuse axonal injury (DAI) is a common type of primary neuronal injury in patients with severe traumatic brain injury, and is frequently accompanied by tissue tear haemorrhage. The T2*-weighted gradient-recalled echo (GRE) sequences are more sensitive than T2-weighted spin-echo images for detection of haemorrhage. This study was undertaken to determine whether turbo-PEPSI, an extremely fast multi-echo-planar-imaging sequence, can be used as an alternative to the GRE sequence for detection of DAI. Nineteen patients (mean age 24,5 year) with severe traumatic brain injury (TBI), occurred at least 3 months earlier, underwent a brain MRI study on a 1.5-Tesla scanner. A qualitative evaluation of the turbo-PEPSI sequences was performed by identifying the optimal echo time and in-plane resolution. The number and size of DAI lesions, as well as the signal intensity contrast ratio (SI CR), were computed for each set of GRE and turbo-PEPSI images, and divided according to their anatomic location into lobar and/or deep brain. There was no significant difference between GRE and turbo-PEPSI sequences in the total number of DAI lesions detected (283 vs 225 lesions, respectively). The GRE sequence identified a greater number of hypointense lesions in the temporal lobe compared to the t-PEPSI sequence (72 vs 35, pPEPSI than for the GRE sequence (pPEPSI sequence can be used as an alternative to the GRE to assess brain DAI in severe TBI patients, especially if uncooperative and medically unstable.

  5. Spin-echo Echo-planar Imaging MR Elastography versus Gradient-echo MR Elastography for Assessment of Liver Stiffness in Children and Young Adults Suspected of Having Liver Disease.

    Science.gov (United States)

    Serai, Suraj D; Dillman, Jonathan R; Trout, Andrew T

    2017-03-01

    Purpose To compare two-dimensional (2D) gradient-recalled echo (GRE) and 2D spin-echo (SE) echo-planar imaging (EPI) magnetic resonance (MR) elastography for measurement of hepatic stiffness in pediatric and young adult patients suspected of having liver disease. Materials and Methods In this institutional review board-approved, HIPAA-compliant study, 58 patients underwent both 2D GRE and 2D SE-EPI MR elastography at 1.5 T during separate breath holds. Liver stiffness (mean of means; in kilopascals) was measured by five blinded reviewers. Pooled mean liver stiffness and region-of-interest (ROI) size were compared by using paired t tests. Intraclass correlation coefficients (ICCs) were used to assess agreement between techniques. Respiratory motion artifacts were compared across sequences by using the Fisher exact test. Results Mean patient age was 14.7 years ± 5.2 (standard deviation; age range, 0.7-20.5 years), and 55.2% (32 of 58) of patients were male. Mean liver stiffness was 2.92 kPa ± 1.29 measured at GRE MR elastography and 2.76 kPa ± 1.39 at SE-EPI MR elastography (n = 290; P = .15). Mean ROI sizes were 8495 mm 2 ± 4482 for 2D GRE MR elastography and 15 176 mm 2 ± 7609 for 2D SE-EPI MR elastography (n = 290; P range, 0.91-0.95). Moderate or severe breathing artifacts were observed on 27.5% (16 of 58) of 2D GRE images versus 0% 2D SE-EPI images (P < .001). Conclusion There is excellent agreement on measured hepatic stiffness between 2D GRE and 2D SE-EPI MR elastography across multiple reviewers. SE-EPI MR elastography allowed for stiffness measurement across larger areas of the liver and can be performed in a single breath hold. © RSNA, 2016.

  6. Centrically reordered inversion recovery half-Fourier single-shot turbo spin-echo sequence: improvement of the image quality of oxygen-enhanced MRI

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Hatabu, Hiroto; Higashino, Takanori; Kawamitsu, Hideaki; Watanabe, Hirokazu; Takenaka, Daisuke; Cauteren, Marc van; Sugimura, Kazuro

    2004-01-01

    Purpose: The purpose of the study presented here was to determine the improvement in image quality of oxygen-enhanced magnetic resonance (MR) subtraction imaging obtained with a centrically reordered inversion recovery half-Fourier single-shot turbo spin-echo (c-IR-HASTE) sequence compared with that obtained with a conventional sequentially reordered inversion recovery single-shot HASTE (s-IR-HASTE) sequence for pulmonary imaging. Materials and methods: Oxygen-enhanced MR imaging using a 1.5 T whole body scanner was performed on 12 healthy, non-smoking volunteers. Oxygen-enhanced MR images were obtained with the coronal two-dimensional (2D) c-IR-HASTE sequence and 2D s-IR-HASTE sequence combined with respiratory triggering. For a 256x256 matrix, 132 phase-encoding steps were acquired including four steps for phase correction. Inter-echo spacing for each sequence was 4.0 ms. The effective echo time (TE) for c-IR-HASTE was 4.0 ms, and 16 ms for s-IR-HASTE. The inversion time (TI) was 900 ms. To determine the improvement in oxygen-enhanced MR subtraction imaging by c-IR-HASTE, CNRs of subtraction image, overall image quality, and image degradation of the c-IR-HASTE and s-IR-HASTE techniques were statistically compared. Results: CNR, overall image quality, and image degradation of c-IR-HASTE images showed significant improvement compared to those s-IR-HASTE images (P<0.05). Conclusion: Centrically reordered inversion recovery half-Fourier single-shot turbo spin-echo (c-IR-HASTE) sequence enhanced the signal from the lung and improved the image quality of oxygen-enhanced MR subtraction imaging

  7. Moderately T2-weighted images obtained with the single-shot fast spin-echo technique. Differentiating between malignant and benign urinary obstructions

    International Nuclear Information System (INIS)

    Obuchi, Masao; Sugimoto, Hideharu; Kubota, Hayato; Yamamoto, Wakako; Kinebuchi, Yuko; Honda, Minoru; Takahara, Taro

    2002-01-01

    The purpose of this study was to determine whether a distinction could be made between benign and malignant urinary obstructions in moderately T 2 -weighted images obtained with the single-shot fast spin-echo technique. Forty-four lesions in 39 patients with urinary obstruction were evaluated with the single-shot fast spin-echo (SSFSE) technique with an effective TE of 90-100 ms and without fat saturation. Benign and malignant lesions were compared for the presence of ureteral wall thickening and a signal intensity relative to the proximal ureteral wall. Statistically significant differences were found between benign and malignant lesions in both morphologic change (P 2 -weighted SSFSE technique without fat saturation can accurately distinguish between benign and malignant urinary obstructions. (author)

  8. Comparative Analysis of Signal Intensity and Apparent Diffusion Coefficient at Varying b-values in the Brain : Diffusion Weighted-Echo Planar Image (T2 and FLAIR) Sequence

    International Nuclear Information System (INIS)

    Oh, Jong Kap; Im, Jung Yeol

    2009-01-01

    Diffusion-weighted imaging (DWI) has been demonstrated to be a practical method for the diagnosis of various brain diseases such as acute infarction, brain tumor, and white matter disease. In this study, we used two techniques to examine the average signal intensity (SI) and apparent diffusion coefficient (ADC) of the brains of patients who ranged in age from 10 to 60 years. Our results indicated that the average SI was the highest in amygdala (as derived from DWI), whereas that in the cerebrospinal fluid was the lowest. The average ADC was the highest in the cerebrospinal fluid, whereas the lowest measurement was derived from the pons. The average SI and ADC were higher in T 2 -DW-EPI than in FLAIR-DW-EPI. The higher the b-value, the smaller the average difference in both imaging techniques; the lower the b-value, the greater the average difference. Also, comparative analysis of the brains of patients who had experienced cerebral infarction showed no distinct lesion in the general MR image over time. However, there was a high SI in apparent weighted images. Analysis of other brain diseases (e.g., bleeding, acute, subacute, chronic infarction) indicated SI variance in accordance with characteristics of the two techniques. The higher the SI, the lower the ADC. Taken together, the value of SI and ADC in accordance with frequently occurring areas and various brain disease varies based on the b-value and imaging technique. Because they provide additional useful information in the diagnosis and treatment of patients with various brain diseases through signal recognition, the proper imaging technique and b-value are important for the detection and interpretation of subacute stroke and other brain diseases.

  9. Gadolinium-enhanced MR imaging of normal renal transplants. An evaluation of a T1-weighted dynamic echo-planar sequence

    International Nuclear Information System (INIS)

    Dupas, B.; Blancho, G.; Havet, T.; Leaute, F.

    1999-01-01

    Purpose: To evaluate the potential usefulness of dynamic MR with echoplanar imaging (EPI) in assessing the renal function in patients with renal allografts. Material and methods: Using a T1-weighted sequence, EPI was performed after injection of a Gd-chelate in 17 patients with normally functioning renal allografts. Time-intensity curves were plotted from the signal intensity (SI) measurements of the cortex and the medulla. Results: The pattern of corticomedullar differentiation (CMD) observed after constrast enhancement was divided into four phases using the T1-EPI. After a rapid decrease in the SI of cortical structures, and a subsequent return to precontrast levels, a gradual fall in the SI of the medulla was observed. The average time between the two periods of signal loss was 60 s. Conclusion: This study illustrated the potential use of dynamic T1-EPI to demonstrate contrast-induced CMD in renal allografts. (orig.)

  10. Diffusion-weighted echo-planar MRI of lacunar infarcts

    International Nuclear Information System (INIS)

    Noguchi, K.; Nagayoshi, T.; Watanabe, N.; Kanazawa, T.; Toyoshima, S.; Morijiri, M.; Shojaku, H.; Shimizu, M.; Seto, H.

    1998-01-01

    We studied 35 patients with lacunar infarcts, using diffusion-weighted echo-planar imaging (DW-EPI) at 1.5 T. The relative apparent diffusion coefficient ratio (ADCR) of each lesion was calculated and lesion conspicuity on DW-EPI was compared to that on images aquired with fast fluid-attenuated inversion recovery and T2-weighted fast spin-echo sequences. Acute small infarcts (within 3 days) were identified with DW-EPI as an area of decreased ADCR (range 0.33-0.87; mean 0.67) and high signal, subacute small infarcts (4-30 days) as a high-signal or isointense areas of decreased or nearly normal ADCR (0.54-0.98; 0.73), and chronic small infarcts (> 30 days) as low- or high-signal areas of nearly normal or increased ADCR (0.97-1.92; 1.32). In three patients, small infarcts of the brain stem in the hyperacute phase (within 6 h) were seen only with DW-EPI. In five patients, fresh small infarcts adjacent to multiple old infarcts could be distinguished only with DW-EPI. (orig.)

  11. Distortion-free diffusion tensor imaging for evaluation of lumbar nerve roots: Utility of direct coronal single-shot turbo spin-echo diffusion sequence.

    Science.gov (United States)

    Sakai, Takayuki; Doi, Kunio; Yoneyama, Masami; Watanabe, Atsuya; Miyati, Tosiaki; Yanagawa, Noriyuki

    2018-06-01

    Diffusion tensor imaging (DTI) based on a single-shot echo planer imaging (EPI-DTI) is an established method that has been used for evaluation of lumbar nerve disorders in previous studies, but EPI-DTI has problems such as a long acquisition time, due to a lot of axial slices, and geometric distortion. To solve these problems, we attempted to apply DTI based on a single-shot turbo spin echo (TSE-DTI) with direct coronal acquisition. Our purpose in this study was to investigate whether TSE-DTI may be more useful for evaluation of lumbar nerve disorders than EPI-DTI. First, lumbar nerve roots of five healthy volunteers were evaluated for optimization of imaging parameters with TSE-DTI including b-values and the number of motion proving gradient (MPG) directions. Subsequently, optimized TSE-DTI was quantitatively compared with conventional EPI-DTI by using fractional anisotropy (FA) values and visual scores in subjective visual evaluation of tractography. Lumbar nerve roots of six patients, who had unilateral neurologic symptoms in one leg, were evaluated by the optimized TSE-DTI. TSE-DTI with b-value of 400 s/mm 2 and 32 diffusion-directions could reduce the image distortion compared with EPI-DTI, and showed that the average FA values on the symptomatic side for six patients were significantly lower than those on the non-symptomatic side (P DTI might show damaged areas of lumbar nerve roots without severe image distortion. TSE-DTI might improve the reproducibility in measurements of FA values for quantification of a nerve disorder, and would become a useful tool for diagnosis of low back pain. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Imaging of the normal and abnormal pancreaticobiliary system with single-shot MR cholangiopancreatography: a pictorial review

    International Nuclear Information System (INIS)

    Little, A. F.; Smith, P.J.; Lee, W.K.; Hennessy, O.F.; Lourensz, M.E.; Desmond, P.V.; Banting, S.W.

    1999-01-01

    Magnetic resonance cholangiopancreatography (MRCP) is a rapidly evolving non-invasive imaging modality that produces images of the pancreatic duct and binary tree without the need for intravenous or oral contrast. The images are equivalent to those from endoscopic retrograde cholangiopancreatography (ERCP), but the non-invasive acquisition avoids the morbidity and mortality associated with diagnostic ERCP. Magnetic resonance cholangiopancreatography is indicated in patients who require only a diagnostic ERCP, who fail an ERCP or who are unable to undergo ERCP due to altered post-surgical anatomy. Other evolving indications include triaging of patients with obstructive jaundice into percutaneous or endoscopic management drainage pathways depending on the site, length and nature of the duct obstruction, thereby potentially decreasing the number of failed or unsuccessful ERCP. Preoperative identification of anomalous binary anatomy and choledocholithiasis prior to laparoscopic cholecystectomy promise to modify the pre-operative and operative management of the patient in order to minimize the risk of duct injury and unnecessary intra-operative dissection and cholangiography. The advantages of the technique include its non-invasiveness, the absence of contrast administration, its relative operator independence and the ability to evaluate both sides of an obstructed duct, thereby accurately evaluating stricture morphology and length. The disadvantages of MRCP compared to ERCP include its lack of an immediate therapeutic solution to duct obstruction, procedural cost, unit availability and the inability to evaluate patients with pacemakers or ferromagnetic implants. Copyright (1999) Blackwell Science Pty Ltd

  13. Faster pediatric 3-T abdominal magnetic resonance imaging: comparison between conventional and variable refocusing flip-angle single-shot fast spin-echo sequences

    Energy Technology Data Exchange (ETDEWEB)

    Ruangwattanapaisarn, Nichanan [Mahidol University, Department of Diagnostic and Therapeutic Radiology, Ramathibodi Hospital, Bangkok (Thailand); Stanford University, LPCH Department of Radiology, Stanford, CA (United States); Loening, Andreas M.; Saranathan, Manojkumar; Vasanawala, Shreyas S. [Stanford University, LPCH Department of Radiology, Stanford, CA (United States); Litwiller, Daniel V. [GE Healthcare, Rochester, MN (United States)

    2015-06-15

    Single-shot fast spin echo (SSFSE) is particularly appealing in pediatric patients because of its motion robustness. However radiofrequency energy deposition at 3 tesla forces long pauses between slices, leading to longer scans, longer breath-holds and more between-slice motion. We sought to learn whether modulation of the SSFSE refocusing flip-angle train could reduce radiofrequency energy deposition without degrading image quality, thereby reducing inter-slice pauses and overall scan times. We modulated the refocusing flip-angle train for SSFSE to minimize energy deposition while minimizing blurring and motion-related signal loss. In a cohort of 50 consecutive patients (25 boys, mean age 5.5 years, range 1 month to 17 years) referred for abdominal MRI we obtained standard SSFSE and variable refocusing flip-angle (vrfSSFSE) images and recorded sequence scan times. Two readers independently scored the images in blinded, randomized order for noise, tissue contrast, sharpness, artifacts and left lobe hepatic signal uniformity on a four-point scale. The null hypothesis of no difference between SSFSE and vrfSSFSE image-quality was assessed with a Mann-Whitney U test, and the null hypothesis of no scan time difference was assessed with the paired t-test. SSFSE and vrfSSFSE mean acquisition times were 54.3 and 26.2 s, respectively (P-value <0.0001). For each reader, SSFSE and vrfSSFSE noise, tissue contrast, sharpness and artifacts were not significantly different (P-values 0.18-0.86). However, SSFSE had better left lobe hepatic signal uniformity (P < 0.01, both readers). vrfSSFSE is twice as fast as SSFSE, with equivalent image quality with the exception of left hepatic lobe signal heterogeneity. (orig.)

  14. The role of MR imaging with Half Fourier Acquired Single Shot Turbo Spin Echo sequence in the diagnosis of lung lesions in comparison with multislice CT

    International Nuclear Information System (INIS)

    Hekimoglu, B.; Gurgen, F.; Tatar, I.G.; Aydin, H.; Kizilgoz, V.; Keyik, B.

    2013-01-01

    Objective: To compare the diagnostic values of magnetic resonance imaging using Half Fourier Acquired Single Shot Turbo Spin Echo sequence and multidetector computed tomography in patients with pathologically examined pulmonary lesions. Methods: The retrospective, descriptive study was conducted at Radiology Department, Diskapi Research Hospital, Ankara, Turkey, and comprised records of patients with pathologically examined pulmonary lesions between May 2009 and March 2012. Patients were divided into three groups and examined by both multi dedector computed tomography and magnetic resonance imaging. During the imaging, patients were not administered any intravenous contrast medium. Electrocardiogram gating and breath holding were not performed in echo sequence. Pulmonary lesions were evaluated on the basis of their dimensions, numbers, differentiation from atelectasis and consolidation, invasion to the thoracic wall-mediastinal structures and presence of lymphadenopathies. Results: Sensitivity of all patients was 50% (p=0.214) and specificity of CT and MRI were 82.5% (p=0.134) for the detectability of submilimetric nodules . For differentiation of the mass from atelectasis and consolidation, the sensitivity of computed tomography was statistically more significant compared to magnetic resonance imaging (86.6%; p=0.035). For the invasion of the mass to the mediastinal structures and the thoracic wall, the sensitivity of magnetic resonance imaging was statistically more significant compared to tomography (86.6%; p=0.035). Conclusion: HASTE sequence can be used to determine the invasion of the pulmonary mass to the mediastinal structures and the thoracic wall since it is more sensitive than computed tomography. It can also be used to detect submilimetric nodules. It has equal sensitivity and specificity compared to computed tomography. But computed tomography is superior for the differentiation of the mass from atelectasis and consolidation. (author)

  15. Comparison of single-shot fast spin-echo sequence and T2-weighted fast spin-echo sequence in MR imaging of the brain

    International Nuclear Information System (INIS)

    Cha, Sung Ho; Seo, Jeong Jin; Jeong, Gwang Woo; Kim, Jae Kyu; Kim, Yun Hyeon; Jeong, Yong Yeon; Kang, Heoung Keun; Oh, Hee Yeon; Yoon, Jong Hoon

    1998-01-01

    The purpose of this study was to evaluate the usefulness of the single-shot fast spinecho (SS-FSE) sequence in comparison with the T2-weighted fast spin-echo (T2-FSE) sequence in brain MR imaging. In 41 patients aged 15-75 years with intracranial lesion, both SS-FSE and T2-FES images were obtained using a 1.5-T MR system. Lesions included cerebral ischemia or infarcts (n=3D23), tumors (n=3D10), hemorrhages (n=3D3), inflammatory diseases (n=3D2), arachnoid cysts(n=3D2), and vascular disease (n=3D1), and the MR images were retrospectively evaluated. To calculate contrast-to-noise ratio (CNR), percentage contrast, and signal-to-noise ratio (SNR)-and thus make a quantitative comparison-the mean signal intensities of lesions, normal brain tissue, and noise out-side the patient were measured. For qualitative comparison, the visibility, margin, and extent of the lesions were rated using a five-grade system, and the degree of MR artifacts was also evaluated. Wilcoxon's signed ranks test was used for statistical analysis. The mean CNR of lesions was significantly higher on SS-FSE (31.3) than on T2-FSE images (27.5) (p=3D0.0131). Mean percentage contrast was also higher on SS-FSE (159.0) than on T2-FSE images (108.5) (p=3D0.0222), but mean SNR was higher on T2-FSE (80.3) than on SS-FSE images (53.5) (p=3D0.0000). No significant differences in lesion visibility were observed between the two imaging sequences, though margin and extent of the lesion were worse on SS-FSE images. For MR artifacts, no significant differences were demonstrated. For the evaluation of most intracranial lesions, MR imaging using the SS-FSE sequence appears to be slightly inferior to the T2-FSE sequence, but may be useful where patients are ill or uncooperative, or where children require sedation.=20

  16. Differential diagnosis of pituitary adenomas and Rathke's cleft cysts by diffusion-weighted MRI using single-shot fast spin echo technique

    International Nuclear Information System (INIS)

    Abe, Takumi; Izumiyama, Hitoshi; Fukuda, Ataru; Tanioka, Daisuke; Kunii, Norihiko; Komatsu, Daisuke; Fujita, Shogo; Ukisu, Ryutaro; Moritani, Toshio

    2002-01-01

    The purpose of the present study was to prospectively evaluate the diagnostic ability of diffusion-weighted magnetic resonance imaging (DWI) using single-shot fast spin echo (SSFSE) technique to discriminate pituitary adenomas from Rathke's cleft cysts. DWIs were obtained from 40 patients with pathologically proven pituitary macroadenomas and 15 patients with proven Rathke's cleft cysts. Pituitary adenomas were divided into 27 cases with solid components alone, five with non-hemorrhagic large cysts, and eight with intratumoral hemorrhage. On SSFSE DWI, solid components of pituitary adenomas revealed iso or slightly increased intensity and intratumoral hemorrhage showed higher intensity than normal brain parenchyma, whereas Rathke's cleft cysts and intratumoral cysts demonstrated very low intensity. SSFSE DWI did not display the susceptibility artifacts that are seen close to the skull base and sinonasal cavities on echo planar diffusion imaging. On the basis of our preliminary findings, DWI may enable us to differentiate pituitary adenomas with only solid components and hemorrhagic pituitary adenomas appearing hyperintense on T1-weighted images from Rathke's cleft cysts without administration of gadolinium-DTPA. SSFSE DWI appears to be a useful technique for characterizing pituitary diseases without the susceptibility artifacts. Our study is the first report to demonstrate the identification of pituitary disorders on SSFSE DWI. (author)

  17. Differential diagnosis of pituitary adenomas and Rathke's cleft cysts by diffusion-weighted MRI using single-shot fast spin echo technique

    Energy Technology Data Exchange (ETDEWEB)

    Abe, Takumi; Izumiyama, Hitoshi; Fukuda, Ataru; Tanioka, Daisuke; Kunii, Norihiko; Komatsu, Daisuke; Fujita, Shogo; Ukisu, Ryutaro; Moritani, Toshio [Showa Univ., Tokyo (Japan). School of Medicine

    2002-09-01

    The purpose of the present study was to prospectively evaluate the diagnostic ability of diffusion-weighted magnetic resonance imaging (DWI) using single-shot fast spin echo (SSFSE) technique to discriminate pituitary adenomas from Rathke's cleft cysts. DWIs were obtained from 40 patients with pathologically proven pituitary macroadenomas and 15 patients with proven Rathke's cleft cysts. Pituitary adenomas were divided into 27 cases with solid components alone, five with non-hemorrhagic large cysts, and eight with intratumoral hemorrhage. On SSFSE DWI, solid components of pituitary adenomas revealed iso or slightly increased intensity and intratumoral hemorrhage showed higher intensity than normal brain parenchyma, whereas Rathke's cleft cysts and intratumoral cysts demonstrated very low intensity. SSFSE DWI did not display the susceptibility artifacts that are seen close to the skull base and sinonasal cavities on echo planar diffusion imaging. On the basis of our preliminary findings, DWI may enable us to differentiate pituitary adenomas with only solid components and hemorrhagic pituitary adenomas appearing hyperintense on T1-weighted images from Rathke's cleft cysts without administration of gadolinium-DTPA. SSFSE DWI appears to be a useful technique for characterizing pituitary diseases without the susceptibility artifacts. Our study is the first report to demonstrate the identification of pituitary disorders on SSFSE DWI. (author)

  18. Real-time movie image enhancement in NMR

    International Nuclear Information System (INIS)

    Doyle, M.; Mansfield, P.

    1986-01-01

    Clinical NMR motion picture (movie) images can now be produced routinely in real-time by ultra-high-speed echo-planar imaging (EPI). The single-shot image quality depends on both pixel resolution and signal-to-noise ratio (S/N), both factors being intertradeable. If image S/N is sacrificed rather than resolution, it is shown that S/N may be greatly enhanced subsequently without vitiating spatial resolution or foregoing real motional effects when the object motion is periodic. This is achieved by a Fourier filtering process. Experimental results are presented which demonstrate the technique for a normal functioning heart. (author)

  19. Comparative Analysis of Signal Intensity and Apparent Diffusion Coefficient at Varying b-values in the Brain : Diffusion Weighted-Echo Planar Image (T{sub 2} and FLAIR) Sequence

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Jong Kap [Dept. of Radiology, Cheomdan Medical Center, Gwangju (Korea, Republic of); Im, Jung Yeol [Dept. of Digital Management Information Graduate School of Nambu Univesity, Gwangju (Korea, Republic of)

    2009-09-15

    Diffusion-weighted imaging (DWI) has been demonstrated to be a practical method for the diagnosis of various brain diseases such as acute infarction, brain tumor, and white matter disease. In this study, we used two techniques to examine the average signal intensity (SI) and apparent diffusion coefficient (ADC) of the brains of patients who ranged in age from 10 to 60 years. Our results indicated that the average SI was the highest in amygdala (as derived from DWI), whereas that in the cerebrospinal fluid was the lowest. The average ADC was the highest in the cerebrospinal fluid, whereas the lowest measurement was derived from the pons. The average SI and ADC were higher in T{sub 2}-DW-EPI than in FLAIR-DW-EPI. The higher the b-value, the smaller the average difference in both imaging techniques; the lower the b-value, the greater the average difference. Also, comparative analysis of the brains of patients who had experienced cerebral infarction showed no distinct lesion in the general MR image over time. However, there was a high SI in apparent weighted images. Analysis of other brain diseases (e.g., bleeding, acute, subacute, chronic infarction) indicated SI variance in accordance with characteristics of the two techniques. The higher the SI, the lower the ADC. Taken together, the value of SI and ADC in accordance with frequently occurring areas and various brain disease varies based on the b-value and imaging technique. Because they provide additional useful information in the diagnosis and treatment of patients with various brain diseases through signal recognition, the proper imaging technique and b-value are important for the detection and interpretation of subacute stroke and other brain diseases.

  20. Simultaneous pH-sensitive and oxygen-sensitive MRI of human gliomas at 3 T using multi-echo amine proton chemical exchange saturation transfer spin-and-gradient echo echo-planar imaging (CEST-SAGE-EPI).

    Science.gov (United States)

    Harris, Robert J; Yao, Jingwen; Chakhoyan, Ararat; Raymond, Catalina; Leu, Kevin; Liau, Linda M; Nghiemphu, Phioanh L; Lai, Albert; Salamon, Noriko; Pope, Whitney B; Cloughesy, Timothy F; Ellingson, Benjamin M

    2018-04-06

    To introduce a new pH-sensitive and oxygen-sensitive MRI technique using amine proton CEST echo spin-and-gradient echo (SAGE) EPI (CEST-SAGE-EPI). pH-weighting was obtained using CEST estimations of magnetization transfer ratio asymmetry (MTR asym ) at 3 ppm, and oxygen-weighting was obtained using R2' measurements. Glutamine concentration, pH, and relaxation rates were varied in phantoms to validate simulations and estimate relaxation rates. The values of MTR asym and R2' in normal-appearing white matter, T 2 hyperintensity, contrast enhancement, and macroscopic necrosis were measured in 47 gliomas. Simulation and phantom results confirmed an increase in MTR asym with decreasing pH. The CEST-SAGE-EPI estimates of R 2 , R2*, and R2' varied linearly with gadolinium diethylenetriamine penta-acetic acid concentration (R 2  = 6.2 mM -1 ·sec -1 and R2* = 6.9 mM -1 ·sec -1 ). The CEST-SAGE-EPI and Carr-Purcell-Meiboom-Gill estimates of R 2 (R 2  = 0.9943) and multi-echo gradient-echo estimates of R2* (R 2  = 0.9727) were highly correlated. T 2 lesions had lower R2' and higher MTR asym compared with normal-appearing white matter, suggesting lower hypoxia and high acidity, whereas contrast-enhancement tumor regions had elevated R2' and MTR asym , indicating high hypoxia and acidity. The CEST-SAGE-EPI technique provides simultaneous pH-sensitive and oxygen-sensitive image contrasts for evaluation of the brain tumor microenvironment. Advantages include fast whole-brain acquisition, in-line B 0 correction, and simultaneous estimation of CEST effects, R 2 , R2*, and R2' at 3 T. © 2018 International Society for Magnetic Resonance in Medicine.

  1. Study on diffusion anisotropy of cerebral ischemia using diffusion weighted echo-planar MRI

    International Nuclear Information System (INIS)

    Kajima, Toshio

    1997-01-01

    Focal cerebral ischemia was produced by occlusion of the intracranial main cerebral artery with a silicone cylinder in Wistar rats. Diffusion-weighted echo-planar images (DW-EPls) using the motion-probing gradient (MPG) method were acquired at 1-3 hours and 24-48 hours after occlusion. Apparent diffusion coefficients (ADCs) were calculated from these images in ischemic lesions and in normal unoccluded regions. Results were as follows. Ischemic lesions could be detected on the DW-EPIs at 1 hour after occlusion. The ADC of water in the brain tissue was smaller than that of free water as a result of restricted diffusion. Anisotropic diffusion that probably can be attributed to the myelin sheath was observed in the normal white matter. In the ischemic lesions, the ADC decreased rapidly within 1-3 hours after occlusion and then decreased gradually after 24-48 hours. In the ischemic white matter, diffusion anisotropy disappeared at 24-48 hours after occlusion. Diffusion-weighted imaging may have applications in the examination of pathophysiological mechanisms in cerebral ischemia by means of evaluation of ADC and diffusion anisotropy. (author)

  2. Echo-planar MR cerebral blood volume mapping of glomas. Clinical utility

    International Nuclear Information System (INIS)

    Aronen, H.J.; Univ. Central Hospital, Helsinki; Glass, J.; Pardo, F.S.; Belliveau, J.W.; Gruber, M.L.; Buchbinder, B.R.; Gazit, I.E.; Linggood, R.M.; Fischman, A.J.; Rosen, F.S.; Hochberg, F.H.

    1995-01-01

    Neovascularization is a common phenomenon in gliomas. MR imaging cerebral blood volume (CBV) mapping utilizes ultrafast echo-planar imaging and simultaneous use of gadolinium-based contrast material. To determine the utility of MR CBV mapping in the clinical evaluation of gliomas, we followed 15 patients with serial studies. This technique provided functional information that was not evident with conventional CT or MR imaging. Low-grade tumors demonstrated homogeneously low CBV, while high-grade tumors often showed areas of both high and low CBV. The maximum tumor CBV/white matter ratio was compared between low- (n=3) and high-grade gliomas (n=5) in patients without previous treatment and with histologic verification (n=8) and was significantly higher in high-grade gliomas (p<0.01), High CBV foci in nonenhancing tumor areas were present in 2 cases. The distinction between radiation necrosis and active tumor could be made correctly in 3 of 4 cases. The information provided by MR CBV mapping has the potential to be an adjunct in the clinical care of glioma patients. (orig.)

  3. Strategies to improve phase-stability of ultrafast swept source optical coherence tomography for single shot imaging of transient mechanical waves at 16 kHz frame rate

    Energy Technology Data Exchange (ETDEWEB)

    Song, Shaozhen; Wei, Wei; Hsieh, Bao-Yu; Pelivanov, Ivan; O' Donnell, Matthew [Department of Bioengineering, University of Washington, Seattle, Washington 98195 (United States); Shen, Tueng T.; Wang, Ruikang K., E-mail: wangrk@uw.edu [Department of Bioengineering, University of Washington, Seattle, Washington 98195 (United States); Department of Ophthalmology, University of Washington, Seattle, Washington 98104 (United States)

    2016-05-09

    We present single-shot phase-sensitive imaging of propagating mechanical waves within tissue, enabled by an ultrafast optical coherence tomography (OCT) system powered by a 1.628 MHz Fourier domain mode-locked (FDML) swept laser source. We propose a practical strategy for phase-sensitive measurement by comparing the phases between adjacent OCT B-scans, where the B-scan contains a number of A-scans equaling an integer number of FDML buffers. With this approach, we show that micro-strain fields can be mapped with ∼3.0 nm sensitivity at ∼16 000 fps. The system's capabilities are demonstrated on porcine cornea by imaging mechanical wave propagation launched by a pulsed UV laser beam, promising non-contact, real-time, and high-resolution optical coherence elastography.

  4. Comparison of respiratory-triggered 3-D fast spin-echo and single-shot fast spin-echo radial slab MR cholangiopancreatography images in children

    Energy Technology Data Exchange (ETDEWEB)

    Chavhan, Govind B.; Almehdar, Abeer; Gupta, Sumeet [The Hospital for Sick Children and University of Toronto, Department of Diagnostic Imaging, Toronto (Canada); Moineddin, Rahim [University of Toronto, Department of Family and Community Medicine, Toronto (Canada); Babyn, Paul S. [Royal University Hospital, Department of Medical Imaging, Saskatoon (Canada)

    2013-09-15

    The two most commonly performed magnetic resonance cholangiopancreatography (MRCP) sequences, 3-D fast spin-echo (3-D FSE) and single-shot fast spin-echo radial slabs (radial slabs), have not been compared in children. The purpose of this study was to compare 3-D FSE and radial slabs MRCP sequences on a 3-T scanner to determine their ability to show various segments of pancreaticobiliary tree and presence of artifacts in children. We reviewed 79 consecutive MRCPs performed in 74 children on a 3-T scanner. We noted visibility of major ducts on 3-D FSE and radial slabs. We noted the order of branching of ducts in the right and left hepatic ducts and the degree of visibility of the pancreatic duct. Statistical analysis was performed using McNemar and signed rank tests. There was no significant difference in the visibility of major bile ducts and the order of branching in the right hepatic lobe between sequences. A higher order of branching in the left lobe was seen on radial slabs than 3-D FSE (mean order of branching 2.82 versus 2.27; P-value = 0.0002). The visibility of pancreatic duct was better on radial slabs as compared to 3-D FSE (mean value of 1.53 vs. 0.90; P-value < 0.0001). 3-D FSE sequence was artifact-free in 25/79 (31.6%) MRCP exams as compared to radial slabs, which were artifact-free in 18/79 (22.8%) MRCP exams (P-value = 0.0001). There is no significant difference in the visibility of major bile ducts between 3-D FSE and radial slab MRCP sequences at 3-T in children. However, radial slab MRCP shows a higher order of branching in the left hepatic lobe and superior visibility of the pancreatic duct than 3-D FSE. (orig.)

  5. Clinical characteristics in normal healthy adults with microbleeds on echo-planar gradient-echo T2*-weighted MRI

    International Nuclear Information System (INIS)

    Takahashi, Wakoh; Ide, Michiru; Ohnuki, Tomohide; Takagi, Shigeharu; Shinohara, Yukito

    2004-01-01

    The gradient-echo T 2 * -weighted sequence in magnetic resonance imaging is known to be useful for detecting microbleeds (MBs) in patients with intracranial hemorrhage or lacunar stroke. We investigated the characteristics of apparently healthy adults with MBs but without stroke, employing echo-planar gradient-echo T 2 * -weighted MRI. The subjects were recruited from among 3,537 participants who underwent brain check-ups at the HIMEDIC Imaging Center. Of the 3,537 participants, 3,296 (mean age, 55±11 years) without any history of cerebrovascular disease or apparent focal neurological manifestations were selected for the present study. MBs on echo-planar gradient-echo T 2 * -weighted MRI were observed in 74 (2.2%) of the 3,296 subjects. Of a total of 133 lesions found in these 74 persons, 31 were located in the basal ganglia or cortico-subcortical regions. Thirty were in the deep white matter, 19 in the thalamus, 16 in the cerebellum, and 6 in the brain stem. The subjects with MBs were significantly older than the subjects without MBs, and the mean values for their systolic and diastolic blood pressures were higher than those in the subjects without MBs. Asymptomatic cerebral infarction, periventricular hyperintensity, and deep and subcortical white matter hyperintensity on T 1 - and T 2 -weighted MRI were more frequent in the subjects with MBs, as compared with those without MBs. Asymptomatic cerebral infarction, periventricular hyperintensity, and deep and subcortical white matter hyperintensity on T 1 - and T 2 -weighted MRI were more frequent in the subjects with MBs of the basal ganglia or thalamus than in those with MBs in other regions. MBs on echo-planar gradient-echo T 2 * -weighted MRI were thus relatively rare in apparently healthy adults. However, MBs in the basal ganglia or thalamus are suggested to be closely related to intracerebral microangiopathy. Persons with MBs in such regions should therefore be carefully checked for cerebrovascular risk

  6. Single-shot 35 fs temporal resolution electron shadowgraphy

    Energy Technology Data Exchange (ETDEWEB)

    Scoby, C. M.; Li, R. K.; Threlkeld, E.; To, H.; Musumeci, P. [Department of Physics and Astronomy, UCLA, Los Angeles, California 90095 (United States)

    2013-01-14

    We obtain single-shot time-resolved shadowgraph images of the electromagnetic fields resulting from the interaction of a high intensity ultrashort laser pulse with a metal surface. Using a high brightness relativistic electron beam and a high streaking speed radiofrequency deflector, we report <35 fs temporal resolution enabling a direct visualization of the retarded-time dominated field evolution which follows the laser-induced charge emission. A model including the finite signal propagation speed well reproduces the data and yields measurements of fundamental parameters in short pulse laser-matter interaction such as the amount of emitted charge and the emission time scale.

  7. Single-shot 35 fs temporal resolution electron shadowgraphy

    International Nuclear Information System (INIS)

    Scoby, C. M.; Li, R. K.; Threlkeld, E.; To, H.; Musumeci, P.

    2013-01-01

    We obtain single-shot time-resolved shadowgraph images of the electromagnetic fields resulting from the interaction of a high intensity ultrashort laser pulse with a metal surface. Using a high brightness relativistic electron beam and a high streaking speed radiofrequency deflector, we report <35 fs temporal resolution enabling a direct visualization of the retarded-time dominated field evolution which follows the laser-induced charge emission. A model including the finite signal propagation speed well reproduces the data and yields measurements of fundamental parameters in short pulse laser-matter interaction such as the amount of emitted charge and the emission time scale.

  8. Diffusion tensor trace mapping in normal adult brain using single-shot EPI technique: A methodological study of the aging brain

    International Nuclear Information System (INIS)

    Chen, Z.G.; Hindmarsh, T.; Li, T.Q.

    2001-01-01

    Purpose: To quantify age-related changes of the average diffusion coefficient value in normal adult brain using orientation-independent diffusion tensor trace mapping and to address the methodological influences on diffusion quantification. Material and Methods: Fifty-four normal subjects (aged 20-79 years) were studied on a 1.5-T whole-body MR medical unit using a diffusion-weighted single-shot echo-planar imaging technique. Orientation-independent diffusion tensor trace maps were constructed for each subject using diffusion-weighted MR measurements in four different directions using a tetrahedral gradient combination pattern. The global average (including cerebral spinal fluid) and the tissue average of diffusion coefficients in adult brains were determined by analyzing the diffusion coefficient distribution histogram for the entire brain. Methodological influences on the measured diffusion coefficient were also investigated by comparing the results obtained using different experimental settings. Results: Both global and tissue averages of the diffusion coefficient are significantly correlated with age (p<0.03). The global average of the diffusion coefficient increases 3% per decade after the age of 40, whereas the increase in the tissue average of diffusion coefficient is about 1% per decade. Experimental settings for self-diffusion measurements, such as data acquisition methods and number of b-values, can slightly influence the statistical distribution histogram of the diffusion tensor trace and its average value. Conclusion: Increased average diffusion coefficient in adult brains with aging are consistent with findings regarding structural changes in the brain that have been associated with aging. The study also demonstrates that it is desirable to use the same experimental parameters for diffusion coefficient quantification when comparing between different subjects and groups of interest

  9. Novel use of non-echo-planar diffusion weighted MRI in monitoring disease activity and treatment response in active Grave's orbitopathy: An initial observational cohort study.

    Science.gov (United States)

    Lingam, Ravi Kumar; Mundada, Pravin; Lee, Vickie

    2018-01-10

    To examine the novel use of non-echo-planar diffusion weighted MRI (DWI) in depicting activity and treatment response in active Grave's orbitopathy (GO) by assessing, with inter-observer agreement, for a correlation between its apparent diffusion coefficients (ADCs) and conventional Short tau Inversion Recovery (STIR) MRI signal-intensity ratios (SIRs). A total of 23 actively inflamed muscles and 30 muscle response episodes were analysed in patients with active GO who underwent medical treatment. The MRI orbit scans included STIR sequences and non-echo-planar DWI were evaluated. Two observers independently assessed the images qualitatively for the presence of activity in the extraocular muscles (EOMs) and recorded the STIR signal-intensity (SI), SIR (SI ratio of EOM/temporalis muscle), and ADC values of any actively inflamed muscle on the pre-treatment scans and their corresponding values on the subsequent post-treatment scans. Inter-observer agreement was examined. There was a significant positive correlation (0.57, p < 0.001) between ADC and both SIR and STIR SI of the actively inflamed EOM. There was also a significant positive correlation (0.75, p < 0.001) between SIR and ADC values depicting change in muscle activity associated with treatment response. There was good inter-observer agreement. Our preliminary results indicate that quantitative evaluation with non-echo-planar DWI ADC values correlates well with conventional STIR SIR in detecting active GO and monitoring its treatment response, with good inter-observer agreement.

  10. Single-shot self-interference incoherent digital holography using off-axis configuration.

    Science.gov (United States)

    Hong, Jisoo; Kim, Myung K

    2013-12-01

    We propose a single-shot incoherent holographic imaging technique that adopts self-interference incoherent digital holography (SIDH) with slight tilt of the plane mirror in the optical configuration. The limited temporal coherence length of the illumination leads the guide-star hologram of the proposed system to have a Gaussian envelope of elliptical ring shape. The observation shows that the reconstruction by cross correlation with the guide-star hologram achieves better quality than the usual propagation methods. Experimentally, we verify that the hologram and 3D reconstruction can be implemented incoherently with the proposed single-shot off-axis SIDH.

  11. Detection of hyperacute parenchymal hemorrhage of the brain using echo-planar T2{sup *}-weighted and diffusion-weighted MRI

    Energy Technology Data Exchange (ETDEWEB)

    Wiesmann, M. [Dept. of Radiology, Medizinische Universitaet zu Luebeck (Germany); Mayer, T.E.; Yousry, I.; Brueckmann, H. [Dept. of Neuroradiology, Klinikum Grosshadern, Ludwig-Maximilians-Universitaet, Muenchen (Germany); Hamann, G.F. [Dept. of Neurology, Klinikum Grosshadern, Ludwig-Maximilians-Universitaet, Muenchen (Germany)

    2001-05-01

    We investigated the usefulness of echo-planar imaging (EPI) as well as T2{sup *}-weighted and diffusion-weighted MRI (DWI) to identify hyperacute hemorrhage (within 24 h after ictus) in the brain. Seven patients were examined 3.5 to 24 h after onset of symptoms using a whole-body 1.5-T MR system. Two diffusion-weighted sequences were run to obtain isotropic and anisotropic diffusion images. Apparent diffusion coefficients (ADC) were calculated from the isotropic diffusion images. All DWI images as well as the T2*-weighted EPI images showed the hematomas as either discrete, deeply hypointense homogeneous lesions, or as lesions of mixed signal intensity containing hypointense areas. We conclude that even in the early phase after hemorrhage, sufficient amounts of paramagnetic deoxyhemoglobin are present in intracerebral hemorrhages to cause hypointensity on EPI T2{sup *}-weighted and DWI images; thus, use of ultrafast EPI allows identification of intracerebral hemorrhage. (orig.)

  12. The single-shot opto-digitizer

    International Nuclear Information System (INIS)

    Nail, M.; Gibert, Ph.

    2000-01-01

    Laser-plasma experiments need to measure signals provided either by X-ray, photonic or neutronic detector. The measurement should have 50 GHz bandwidth and up to several hundred of Giga-Hertz for sub picosecond plasmas. For this purpose, a 35 GHz single shot opto-digitizer (10 ps risetime) has been studied and built. The device is made up of a 50 ohms microstrip propagation line, periodically lined by 100 sampled gates. The propagation line is long enough to measure a 400 ps duration. The sampling rate is 250 Gsa/s (every 4 ps). The sampled gates are made with fast recombining photo-material and turn on by a subpicosecond laser pulse which is synchronized exactly with the analysed phenomena. Every gate is recording to a storing capacitor. After the recording, every capacitor charge is needed to built the signal that was displayed on the propagation line. The dynamic range of measurement is 47 for the entire device. The device can measure positive or negative signals from 1.5 to 70 Volts. To increase the bandwidth, two another kinds of opto-digitizer were studied: one is a buried stripline with 56 GHz band width, the other a 70 GHz coplanar transmission line. For the purpose of subpicosecond plasmas, a 30 coplanar waveguide opto-digitizer was studied. Characteristics are as followed: window of measurement 40 ps, sampling rate 1 ps, bandwidth 230 GHz. Finally, a bundle of optical fibers was used to propagate the laser beam on semiconductor gates. If the gates are lighted at the same time, i.e. if the optical fibers have the same length, we get a simultaneous addressing. By using different lengths of optical fibers, we can do a sequential addressing. So, the sampling rate becomes a combination of the distance between two adjacent sampled channels, and the difference in length of optical fibers. (author)

  13. Diffusion-weighted MR imaging of the abdomen with pulse triggering

    International Nuclear Information System (INIS)

    Muertz, P.; Pauleit, D.; Traeber, F.; Kreft, B.P.; Schild, H.H.

    2000-01-01

    Purpose: The aim of this work was to reduce the influence of motion on diffusion-weighted MR images of the abdomen by pulse triggering of single-shot sequences. Methods: Five healthy volunteers were examined both without and with finger pulse-triggering of a diffusion-weighted single-shot echo planar MR imaging sequence at 1.5 T. Series of diffusion-weighted images were acquired at different phases of the cardiac cycle by varying the time delay between finger pulse and sequence acquisition. The measurements were repeated three times. The diffusion weighted images were analysed by measuring the signal intensities and by determining the ADC values within the spleen, kidney and liver. Results: The magnitude of motion artifacts on diffusion weighted images shows a strong dependence on the trigger delay. The optimum trigger delay is found to be between 500 and 600 ms. For these values the abdominal organs appear homogeneous on all diffusion weighted images and the strongest signal intensities are detected. At optimum triggering the accuracy of the apparent diffusion coefficients is up to 10 times better than without triggering. Moreover, the standard deviation of the repeated measurements is smaller than 12% for all volunteers and for all organs. Without triggering the standard deviation is larger by a factor of 4 on average. Conclusion: Pulse triggering of single-shot sequences leads to significant reduction of motion related artifacts on diffusion weighted images of the abdomen and provides more accurate and reproducible ADC values. (orig.) [de

  14. Ship Detection Using Transfer Learned Single Shot Multi Box Detector

    Directory of Open Access Journals (Sweden)

    Nie Gu-Hong

    2017-01-01

    Full Text Available Ship detection in satellite images is a challenging task. In this paper, we introduce a transfer learned Single Shot MultiBox Detector (SSD for ship detection. To this end, a state-of-the-art object detection model pre-trained from a large number of natural images was transfer learned for ship detection with limited labeled satellite images. To the best of our knowledge, this could be one of the first studies which introduce SSD into ship detection on satellite images. Experiments demonstrated that our method could achieve 87.9% AP at 47 FPS using NVIDIA TITAN X. In comparison with Faster R-CNN, 6.7% AP improvement could be achieved. Effects of the observation resolution has also been studied with the changing input sizes among 300 × 300, 600 × 600 and 900 × 900. It has been noted that the detection accuracy declined sharply with the decreasing resolution that is mainly caused by the missing small ships.

  15. Single-shot measurement of nonlinear absorption and nonlinear refraction.

    Science.gov (United States)

    Jayabalan, J; Singh, Asha; Oak, Shrikant M

    2006-06-01

    A single-shot method for measurement of nonlinear optical absorption and refraction is described and analyzed. A spatial intensity variation of an elliptical Gaussian beam in conjugation with an array detector is the key element of this method. The advantages of this single-shot technique were demonstrated by measuring the two-photon absorption and free-carrier absorption in GaAs as well as the nonlinear refractive index of CS2 using a modified optical Kerr setup.

  16. Normal anatomy of the fetus at MR imaging.

    Science.gov (United States)

    Amin, R S; Nikolaidis, P; Kawashima, A; Kramer, L A; Ernst, R D

    1999-10-01

    Owing to recent advances in magnetic resonance (MR) imaging, the role of obstetric MR imaging has increased in cases in which the results of ultrasonography are equivocal. Fast MR imaging sequences, such as T2-weighted fast spin-echo (SE), half-Fourier single-shot fast SE, 0.5-signal-acquired single-shot fast SE, and echo-planar imaging, have virtually eliminated the need for fetal premedication, with a concomitant improvement in image resolution and diminished blurring. Artifacts related to maternal respiratory motion and fetal motion no longer limit the anatomic detail that can be demonstrated with MR imaging. With such advances in obstetric MR imaging, knowledge of normal fetal anatomy at MR imaging is essential to detect disease in utero. MR imaging can demonstrate fetal anatomy in detail, especially the brain, thorax, abdomen, pelvis, and vasculature. Major developmental structures of the fetus, particularly the cranial nervous system, naso- and oropharynx, lungs, and major abdominal viscera, can be adequately evaluated with targeted fast MR imaging as early as the beginning of the second trimester. However, MR imaging of the heart remains limited. Fetal MR imaging during the first trimester remains controversial secondary to biosafety issues and is limited due to diminutive fetal size.

  17. Single-shot speckle reduction in numerical reconstruction of digitally recorded holograms.

    Science.gov (United States)

    Hincapie, Diego; Herrera-Ramírez, Jorge; Garcia-Sucerquia, Jorge

    2015-04-15

    A single-shot method to reduce the speckle noise in the numerical reconstructions of electronically recorded holograms is presented. A recorded hologram with the dimensions N×M is split into S=T×T sub-holograms. The uncorrelated superposition of the individually reconstructed sub-holograms leads to an image with the speckle noise reduced proportionally to the 1/S law. The experimental results are presented to support the proposed methodology.

  18. Clinical application of EPI diffusion weighted image (DWI) for ischemic brain disease

    International Nuclear Information System (INIS)

    Zenke, Kiichiro; Kusunoki, Katsusuke; Saito, Masahiro; Sadamoto, Kazuhiko; Sakaki, Saburo; Kumon, Yoshiaki; Nagasawa, Kiyoshi

    1999-01-01

    Diffusion-weighted magnetic resonance image (DWI) with Echo Planar imaging (EPI) techniques were utilized in 74 consecutive patients who were suspected or diagnosed as having occlusive cerebrovascular diseases. Of three EPI-DWI techniques-single shot DWI, multi-shot DWI and isotropic DWI-, isotropic DWI was the most useful study for diagnosing occlusive cerebro-vascular disease. EPI-DWI could identify fresh infarction, even small cortical infarctions, in the setting of multiple high intensity lesions shown by T2 weighted image (T2WI), and could detect infarcted lesions early after the onset. In the patients whose lesions were not revealed on the initial EPI-DWIs, new infarcted lesion were not found on later MRIs, and their symptoms disappeared completely. High intensity lesions observed on EPI-DWIs mostly decreased signal intensities about 2 weeks after the onset, and the intensities of lesions in the gray matter were reduced earlier than those in the white matter. (author)

  19. Single shot diffraction of picosecond 8.7-keV x-ray pulses

    Directory of Open Access Journals (Sweden)

    F. H. O’Shea

    2012-02-01

    Full Text Available We demonstrate multiphoton, single shot diffraction images of x rays produced by inverse Compton scattering a high-power CO_{2} laser from a relativistic electron beam, creating a pulse of 8.7 keV x rays. The tightly focused, relatively high peak brightness electron beam and high photon density from the 2 J CO_{2} laser yielded 6×10^{7} x-ray photons over the full opening angle in a single shot. Single shot x-ray diffraction is performed by passing the x rays though a vertical slit and on to a flat silicon (111 crystal. 10^{2} diffracted photons were detected. The spectrum of the detected x rays is compared to simulation. The diffraction and detection of 10^{2} x rays is a key step to a more efficient time resolved diagnostic in which the number of observed x rays might reach 10^{4}; enabling a unique, flexible x-ray source as a sub-ps resolution diagnostic for studying the evolution of chemical reactions, lattice deformation and melting, and magnetism.

  20. Single-shot positron annihilation lifetime spectroscopy with LYSO scintillators

    Science.gov (United States)

    Alonso, A. M.; Cooper, B. S.; Deller, A.; Cassidy, D. B.

    2016-08-01

    We have evaluated the application of a lutetium yttrium oxyorthosilicate (LYSO) based detector to single-shot positron annihilation lifetime spectroscopy. We compare this detector directly with a similarly configured PbWO4 scintillator, which is the usual choice for such measurements. We find that the signal to noise ratio obtained using LYSO is around three times higher than that obtained using PbWO4 for measurements of Ps excited to longer-lived (Rydberg) levels, or when they are ionized soon after production. This is due to the much higher light output for LYSO (75% and 1% of NaI for LYSO and PbWO4 respectively). We conclude that LYSO is an ideal scintillator for single-shot measurements of positronium production and excitation performed using a low-intensity pulsed positron beam.

  1. Single-shot positron annihilation lifetime spectroscopy with LYSO scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, A.M., E-mail: a.alonso@ucl.ac.uk; Cooper, B.S.; Deller, A.; Cassidy, D.B.

    2016-08-21

    We have evaluated the application of a lutetium yttrium oxyorthosilicate (LYSO) based detector to single-shot positron annihilation lifetime spectroscopy. We compare this detector directly with a similarly configured PbWO{sub 4} scintillator, which is the usual choice for such measurements. We find that the signal to noise ratio obtained using LYSO is around three times higher than that obtained using PbWO{sub 4} for measurements of Ps excited to longer-lived (Rydberg) levels, or when they are ionized soon after production. This is due to the much higher light output for LYSO (75% and 1% of NaI for LYSO and PbWO{sub 4} respectively). We conclude that LYSO is an ideal scintillator for single-shot measurements of positronium production and excitation performed using a low-intensity pulsed positron beam.

  2. Acoustic-noise-optimized diffusion-weighted imaging.

    Science.gov (United States)

    Ott, Martin; Blaimer, Martin; Grodzki, David M; Breuer, Felix A; Roesch, Julie; Dörfler, Arnd; Heismann, Björn; Jakob, Peter M

    2015-12-01

    This work was aimed at reducing acoustic noise in diffusion-weighted MR imaging (DWI) that might reach acoustic noise levels of over 100 dB(A) in clinical practice. A diffusion-weighted readout-segmented echo-planar imaging (EPI) sequence was optimized for acoustic noise by utilizing small readout segment widths to obtain low gradient slew rates and amplitudes instead of faster k-space coverage. In addition, all other gradients were optimized for low slew rates. Volunteer and patient imaging experiments were conducted to demonstrate the feasibility of the method. Acoustic noise measurements were performed and analyzed for four different DWI measurement protocols at 1.5T and 3T. An acoustic noise reduction of up to 20 dB(A) was achieved, which corresponds to a fourfold reduction in acoustic perception. The image quality was preserved at the level of a standard single-shot (ss)-EPI sequence, with a 27-54% increase in scan time. The diffusion-weighted imaging technique proposed in this study allowed a substantial reduction in the level of acoustic noise compared to standard single-shot diffusion-weighted EPI. This is expected to afford considerably more patient comfort, but a larger study would be necessary to fully characterize the subjective changes in patient experience.

  3. Partial Fourier techniques in single-shot cross-term spatiotemporal encoded MRI.

    Science.gov (United States)

    Zhang, Zhiyong; Frydman, Lucio

    2018-03-01

    Cross-term spatiotemporal encoding (xSPEN) is a single-shot approach with exceptional immunity to field heterogeneities, the images of which faithfully deliver 2D spatial distributions without requiring a priori information or using postacquisition corrections. xSPEN, however, suffers from signal-to-noise ratio penalties due to its non-Fourier nature and due to diffusion losses-especially when seeking high resolution. This study explores partial Fourier transform approaches that, acting along either the readout or the spatiotemporally encoded dimensions, reduce these penalties. xSPEN uses an orthogonal (e.g., z) gradient to read, in direct space, the low-bandwidth (e.g., y) dimension. This substantially changes the nature of partial Fourier acquisitions vis-à-vis conventional imaging counterparts. A suitable theoretical analysis is derived to implement these procedures, along either the spatiotemporally or readout axes. Partial Fourier single-shot xSPEN images were recorded on preclinical and human scanners. Owing to their reduction in the experiments' acquisition times, this approach provided substantial sensitivity gains vis-à-vis previous implementations for a given targeted in-plane resolution. The physical origins of these gains are explained. Partial Fourier approaches, particularly when implemented along the low-bandwidth spatiotemporal dimension, provide several-fold sensitivity advantages at minimal costs to the execution and processing of the single-shot experiments. Magn Reson Med 79:1506-1514, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  4. Single-shot femtosecond-pulsed phase-shifting digital holography.

    Science.gov (United States)

    Kakue, Takashi; Itoh, Seiya; Xia, Peng; Tahara, Tatsuki; Awatsuji, Yasuhiro; Nishio, Kenzo; Ura, Shogo; Kubota, Toshihiro; Matoba, Osamu

    2012-08-27

    Parallel phase-shifting digital holography is capable of three-dimensional measurement of a dynamically moving object with a single-shot recording. In this letter, we demonstrated a parallel phase-shifting digital holography using a single femtosecond light pulse whose central wavelength and temporal duration were 800 nm and 96 fs, respectively. As an object, we set spark discharge in atmospheric pressure air induced by applying a high voltage to between two electrodes. The instantaneous change in phase caused by the spark discharge was clearly reconstructed. The reconstructed phase image shows the change of refractive index of air was -3.7 × 10(-4).

  5. Single-shot positron annihilation lifetime spectroscopy with LYSO scintillators

    OpenAIRE

    Alonso, A. M.; Cooper, B. S.; Deller, A.; Cassidy, D. B.

    2016-01-01

    We have evaluated the application of a lutetium yttrium oxyorthosilicate (LYSO) based detector to single-shot positron annihilation lifetime spectroscopy. We compare this detector directly with a similarly configured PbWO4 scintillator, which is the usual choice for such measurements. We find that the signal to noise ratio obtained using LYSO is around three times higher than that obtained using PbWO4 for measurements of Ps excited to longer-lived (Rydberg) levels, or when they are ionized so...

  6. Role of diffusion-weighted echo-planar MRI in distinguishing between brain abscess and tumour: a preliminary report

    International Nuclear Information System (INIS)

    Noguchi, K.; Watanabe, N.; Nagayoshi, T.; Kanazawa, T.; Toyoshima, S.; Shimizu, M.; Seto, H.

    1999-01-01

    Our purpose was to evaluate diffusion-weighted (DW) echo-planar MRI in differentiating between brain abscess and tumour. We examined two patients with surgically confirmed pyogenic brain abscess and 18 with metastatic brain tumours or high-grade glioma, using a 1.5 T system. The apparent diffusion coefficient (ADC) of each necrotic or solid contrast-enhancing lesion was measured with two different b values (20 and 1200 s/mm 2 ). All capsule-stage brain abscesses (4 lesions) and zones of cerebritis (2 lesions) were identified on high-b-value DWI as markedly high-signal areas of decreased ADC (range, 0.58-0.70 [(10-3 mm 2 /s; mean, 0.63)]). All cystic or necrotic portions of brain tumours (14 lesions) were identified on high-b-value DWI as low-signal areas of increased ADC (range, 2.20-3.20 [(10-3 mm 2 /s; mean, 2.70)]). Solid, contrast-enhancing portions of brain tumours (19 lesions) were identified on high-b-value DWI as high-signal areas of sightly decreased or increased ADC (range, 0.77-1.29 [(10-3 mm 2 /s; mean, 0.94)]). Our preliminary results indicate that DW echo-planar MRI be used for distinguishing between brain abscess and tumour. (orig.) (orig.)

  7. Reference-free unwarping of single-shot spatiotemporally encoded MRI using asymmetric self-refocused echoes acquisition

    Science.gov (United States)

    Chen, Ying; Chen, Song; Zhong, Jianhui; Chen, Zhong

    2015-05-01

    This paper presents a phase evolution rewinding algorithm for correcting the geometric and intensity distortions in single-shot spatiotemporally encoded (SPEN) MRI with acquisition of asymmetric self-refocused echo trains. Using the field map calculated from the phase distribution of the source image, the off-resonance induced phase errors are successfully rewound through deconvolution. The alias-free partial Fourier transform reconstruction helps improve the signal-to-noise ratio of the field maps and the output images. The effectiveness of the proposed algorithm was validated through 7 T MRI experiments on a lemon, a water phantom, and in vivo rat head. SPEN imaging was evaluated using rapid acquisition by sequential excitation and refocusing (RASER) which produces uniform T2 weighting. The results indicate that the new technique can more robustly deal with the cases in which the images obtained with conventional single-shot spin-echo EPI are difficult to be restored due to serious field variations.

  8. Kinematic MRI using short TR single shot fast spin echo (SSFSE) in evaluating swallowing

    Energy Technology Data Exchange (ETDEWEB)

    Isogai, Satoshi; Takehara, Yasuo; Isoda, Haruo; Kodaira, Nami; Masunaga, Hatsuko; Ozawa, Fukujirou; Kaneko, Masao [Hamamatsu Univ. School of Medicine, Shizuoka (Japan); Nozaki, Atsushi; Kabasawa, Hiroyuki

    1999-03-01

    The utility of short TR single shot fast spin echo (SSFSE) MR imaging for evaluating swallowing was determined. Five healthy volunteers underwent kinematic MR imaging of swallowing with a 1.5 T MR scanner using the short TR (300 ms) SSFSE sequence. Twenty phases of sagittal sections were acquired within 6 sec, where the temporal resolution was 300 ms. For oral contrast medium, we used prune yogurt juice with Fe added. The image contrast of short TR SSFSE was found to be somewhere like that of T1-weighted images. In all cases, both the buccal and pharyngeal stages of swallowing were successfully depicted. The Fe-added prune yogurt juice performed as a positive contrast medium and helped determine anatomical structures in the buccal stage. Short TR (300 ms) SSFSE was useful in evaluating swallowing. The combined use of Fe-added prune yogurt juice was helpful in enhancing the surface of the oropharynx. (author)

  9. Kinematic MRI using short TR single shot fast spin echo (SSFSE) in evaluating swallowing

    International Nuclear Information System (INIS)

    Isogai, Satoshi; Takehara, Yasuo; Isoda, Haruo; Kodaira, Nami; Masunaga, Hatsuko; Ozawa, Fukujirou; Kaneko, Masao; Nozaki, Atsushi; Kabasawa, Hiroyuki

    1999-01-01

    The utility of short TR single shot fast spin echo (SSFSE) MR imaging for evaluating swallowing was determined. Five healthy volunteers underwent kinematic MR imaging of swallowing with a 1.5 T MR scanner using the short TR (300 ms) SSFSE sequence. Twenty phases of sagittal sections were acquired within 6 sec, where the temporal resolution was 300 ms. For oral contrast medium, we used prune yogurt juice with Fe added. The image contrast of short TR SSFSE was found to be somewhere like that of T1-weighted images. In all cases, both the buccal and pharyngeal stages of swallowing were successfully depicted. The Fe-added prune yogurt juice performed as a positive contrast medium and helped determine anatomical structures in the buccal stage. Short TR (300 ms) SSFSE was useful in evaluating swallowing. The combined use of Fe-added prune yogurt juice was helpful in enhancing the surface of the oropharynx. (author)

  10. Single-shot quantitative phase microscopy with color-multiplexed differential phase contrast (cDPC.

    Directory of Open Access Journals (Sweden)

    Zachary F Phillips

    Full Text Available We present a new technique for quantitative phase and amplitude microscopy from a single color image with coded illumination. Our system consists of a commercial brightfield microscope with one hardware modification-an inexpensive 3D printed condenser insert. The method, color-multiplexed Differential Phase Contrast (cDPC, is a single-shot variant of Differential Phase Contrast (DPC, which recovers the phase of a sample from images with asymmetric illumination. We employ partially coherent illumination to achieve resolution corresponding to 2× the objective NA. Quantitative phase can then be used to synthesize DIC and phase contrast images or extract shape and density. We demonstrate amplitude and phase recovery at camera-limited frame rates (50 fps for various in vitro cell samples and c. elegans in a micro-fluidic channel.

  11. Single-shot dual-wavelength in-line and off-axis hybrid digital holography

    Science.gov (United States)

    Wang, Fengpeng; Wang, Dayong; Rong, Lu; Wang, Yunxin; Zhao, Jie

    2018-02-01

    We propose an in-line and off-axis hybrid holographic real-time imaging technique. The in-line and off-axis digital holograms are generated simultaneously by two lasers with different wavelengths, and they are recorded using a color camera with a single shot. The reconstruction is carried using an iterative algorithm in which the initial input is designed to include the intensity of the in-line hologram and the approximate phase distributions obtained from the off-axis hologram. In this way, the complex field in the object plane and the output by the iterative procedure can produce higher quality amplitude and phase images compared to traditional iterative phase retrieval. The performance of the technique has been demonstrated by acquiring the amplitude and phase images of a green lacewing's wing and a living moon jellyfish.

  12. Accelerator-based Single-shot Ultrafast Transmission Electron Microscope with Picosecond Temporal Resolution and Nanometer Spatial Resolution

    OpenAIRE

    Xiang, D.; Fu, F.; Zhang, J.; Huang, X.; Wang, L.; Wang, X.; Wan, W.

    2014-01-01

    We present feasibility study of an accelerator-based ultrafast transmission electron microscope (u-TEM) capable of producing a full field image in a single-shot with simultaneous picosecond temporal resolution and nanometer spatial resolution. We study key physics related to performance of u-TEMs, and discuss major challenges as well as possible solutions for practical realization of u-TEMs. The feasibility of u-TEMs is confirmed through simulations using realistic electron beam parameters. W...

  13. Single-shot parallel full range complex Fourier-domain optical coherence tomography

    International Nuclear Information System (INIS)

    Huang Bingjie; Bu Peng; Nan Nan; Wang Xiangzhao

    2011-01-01

    We present a method of parallel full range complex Fourier-domain optical coherence tomography (FDOCT) that is capable of acquiring an artifacts-free two-dimensional (2-D) cross-sectional image, i.e. a full range B-scan tomogram, by a single shot of 2-D CCD camera. This method is based on a spatial carrier technique, in which the spatial carrier-frequency is instantaneously introduced into the 2-D spectral interferogram registered in parallel FDOCT by using a grating-generated reference beam. The spatial-carrier-contained 2-D spectral interferogram is processed through Fourier transformation to obtain a complex 2-D spectral interferogram. From the 2-D complex spectral interferomgram, a full range B-scan tomogram is reconstructed. The principle of our method is confirmed by imaging an onion sample.

  14. Hyperspectral interferometry for single-shot absolute measurement of 3-D shape and displacement fields

    Directory of Open Access Journals (Sweden)

    Ruiz P. D.

    2010-06-01

    Full Text Available We propose a method that we call Hyperspectral Interferometry (HSI to resolve the 2π phase unwrapping problem in the analysis of interferograms recorded with a narrow-band light source. By using a broad-band light source and hyperspectral imaging system, a set of interferograms at different wavenumbers are recorded simultaneously on a high resolution image sensor. These are then assembled to form a three-dimensional intensity distribution. By Fourier transformation along the wavenumber axis, an absolute optical path difference is obtained for each pixel independently of the other pixels in the field of view. As a result, interferograms with spatially distinct regions are analysed as easily as continuous ones. The approach is illustrated with a HSI system to measure 3-D profiles of optically smooth or rough surfaces. Compared to existing profilometers able to measure absolute path differences, the single shot nature of the approach provides greater immunity from environmental disturbance.

  15. Ultrafast T2-weighted single shot spin-echo sequences: applications on abdominal and pelvic pathologies

    International Nuclear Information System (INIS)

    Martin, J.; Martin, C.; Falco, J.; Esteban, L.

    1999-01-01

    The magnetic resonance imaging (MRI) sequences that obtain all the data using a sole excitation pulse of 90 degree centigrade, filling the K space in a single repetition time (TR) is known as snap shot or single shot (SS). The SS sequence based on the rapid acquisition with relaxation enhancement (SS-RARE) method, designed by Hening (1) and a variation of it with a half-Fourier reconstruction (SS-HF-RARE (HASTEL)) (2, 3) are capable of obtaining high contrast images in T2, in very short times, that oscillate between one to several seconds. The clinical application of these sequences to abdominal and pelvic pathologies is increasing, providing and improvement in the contrast resolution, but also in the spatial resolution, with a high relation signal/noise ratio, high contrast and absence of movement artifacts. (Author)

  16. High quality single shot diffraction patterns using ultrashort megaelectron volt electron beams from a radio frequency photoinjector

    Energy Technology Data Exchange (ETDEWEB)

    Musumeci, P.; Moody, J. T.; Scoby, C. M.; Gutierrez, M. S. [Department of Physics and Astronomy, UCLA, Los Angeles, California 90095 (United States); Bender, H. A.; Wilcox, N. S. [National Security Technologies, LLC, Los Alamos Operations, Los Alamos, New Mexico 87544 (United States)

    2010-01-15

    Single shot diffraction patterns using a 250-fs-long electron beam have been obtained at the UCLA Pegasus laboratory. High quality images with spatial resolution sufficient to distinguish closely spaced peaks in the Debye-Scherrer ring pattern have been recorded by scattering the 1.6 pC 3.5 MeV electron beam generated in the rf photoinjector off a 100-nm-thick Au foil. Dark current and high emittance particles are removed from the beam before sending it onto the diffraction target using a 1 mm diameter collimating hole. These results open the door to the study of irreversible phase transformations by single shot MeV electron diffraction.

  17. High quality single shot diffraction patterns using ultrashort megaelectron volt electron beams from a radio frequency photoinjector.

    Science.gov (United States)

    Musumeci, P; Moody, J T; Scoby, C M; Gutierrez, M S; Bender, H A; Wilcox, N S

    2010-01-01

    Single shot diffraction patterns using a 250-fs-long electron beam have been obtained at the UCLA Pegasus laboratory. High quality images with spatial resolution sufficient to distinguish closely spaced peaks in the Debye-Scherrer ring pattern have been recorded by scattering the 1.6 pC 3.5 MeV electron beam generated in the rf photoinjector off a 100-nm-thick Au foil. Dark current and high emittance particles are removed from the beam before sending it onto the diffraction target using a 1 mm diameter collimating hole. These results open the door to the study of irreversible phase transformations by single shot MeV electron diffraction.

  18. High quality single shot diffraction patterns using ultrashort megaelectron volt electron beams from a radio frequency photoinjector

    International Nuclear Information System (INIS)

    Musumeci, P.; Moody, J. T.; Scoby, C. M.; Gutierrez, M. S.; Bender, H. A.; Wilcox, N. S.

    2010-01-01

    Single shot diffraction patterns using a 250-fs-long electron beam have been obtained at the UCLA Pegasus laboratory. High quality images with spatial resolution sufficient to distinguish closely spaced peaks in the Debye-Scherrer ring pattern have been recorded by scattering the 1.6 pC 3.5 MeV electron beam generated in the rf photoinjector off a 100-nm-thick Au foil. Dark current and high emittance particles are removed from the beam before sending it onto the diffraction target using a 1 mm diameter collimating hole. These results open the door to the study of irreversible phase transformations by single shot MeV electron diffraction.

  19. Ultrafast MR Imaging in Pediatric Neuroradiology

    International Nuclear Information System (INIS)

    Singh, R.K.; Smith, J.T.; Wilkinson, I.D.; Griffiths, P.D.

    2003-01-01

    Purpose: To compare the diagnostic information obtained from ultrafast MR imaging with standard MR imaging techniques in pediatric neuroradiology. The goal was to judge whether ultrafast methods can be used to replace standard methods and reduce the need for sedation or general anesthesia as a result of the considerably shorter scan times. Material and Methods: Our prospective study involved 125 patients. Routine clinical imaging was performed along with two ultrafast methods. Single shot fast spin echo (SSFSE) was used to give T2-weighted images and an echo planar imaging (EPI) sequence to provide a T1-weighted images. The ultrafast images were presented to an experienced neuro radiologist who was also given the information present on the initial referral card. These reports based on the ultrafast images were then compared with the formal radiologic report made solely on the basis of the standard imaging. Results: The overall sensitivity and specificity for ultrafast imaging when compared to the reference standard were 78% and 98% with positive and negative predictive values of 98% and 76%. Pathologies characterized by small areas of subtle T2 prolongation were difficult or impossible to see on the ultrafast images but otherwise they provided reliable information. Conclusions: This paper demonstrates that ultrafast MR imaging can diagnose many pediatric intracranial abnormalities as well as standard methods. Anatomic resolution limits its capacity to define subtle developmental anomalies and contrast resolution limitations of the ultrafast methods reduce the detection of pathology characterized by subtle T2 prolongation

  20. A functional magnetic resonance imaging study

    Indian Academy of Sciences (India)

    MADU

    systems and ultra fast imaging techniques, such as echo planar imaging (EPI ) ... is used to understand brain organization, assessing of neurological status, and ..... J C 1998 Functional MRI studies of motor recovery after stroke;. NeuroImage 7 ...

  1. Multishot versus single-shot pulse sequences in very high field fMRI: a comparison using retinotopic mapping.

    Directory of Open Access Journals (Sweden)

    Jascha D Swisher

    Full Text Available High-resolution functional MRI is a leading application for very high field (7 Tesla human MR imaging. Though higher field strengths promise improvements in signal-to-noise ratios (SNR and BOLD contrast relative to fMRI at 3 Tesla, these benefits may be partially offset by accompanying increases in geometric distortion and other off-resonance effects. Such effects may be especially pronounced with the single-shot EPI pulse sequences typically used for fMRI at standard field strengths. As an alternative, one might consider multishot pulse sequences, which may lead to somewhat lower temporal SNR than standard EPI, but which are also often substantially less susceptible to off-resonance effects. Here we consider retinotopic mapping of human visual cortex as a practical test case by which to compare examples of these sequence types for high-resolution fMRI at 7 Tesla. We performed polar angle retinotopic mapping at each of 3 isotropic resolutions (2.0, 1.7, and 1.1 mm using both accelerated single-shot 2D EPI and accelerated multishot 3D gradient-echo pulse sequences. We found that single-shot EPI indeed led to greater temporal SNR and contrast-to-noise ratios (CNR than the multishot sequences. However, additional distortion correction in postprocessing was required in order to fully realize these advantages, particularly at higher resolutions. The retinotopic maps produced by both sequence types were qualitatively comparable, and showed equivalent test/retest reliability. Thus, when surface-based analyses are planned, or in other circumstances where geometric distortion is of particular concern, multishot pulse sequences could provide a viable alternative to single-shot EPI.

  2. Real time quantitative phase microscopy based on single-shot transport of intensity equation (ssTIE) method

    Science.gov (United States)

    Yu, Wei; Tian, Xiaolin; He, Xiaoliang; Song, Xiaojun; Xue, Liang; Liu, Cheng; Wang, Shouyu

    2016-08-01

    Microscopy based on transport of intensity equation provides quantitative phase distributions which opens another perspective for cellular observations. However, it requires multi-focal image capturing while mechanical and electrical scanning limits its real time capacity in sample detections. Here, in order to break through this restriction, real time quantitative phase microscopy based on single-shot transport of the intensity equation method is proposed. A programmed phase mask is designed to realize simultaneous multi-focal image recording without any scanning; thus, phase distributions can be quantitatively retrieved in real time. It is believed the proposed method can be potentially applied in various biological and medical applications, especially for live cell imaging.

  3. Reversible changes in echo planar perfusion- and diffusion-weighted MRI in status epilepticus

    International Nuclear Information System (INIS)

    Flacke, S.; Keller, E.; Urbach, H.; Wuellner, U.; Hamzei, F.

    2000-01-01

    Perfusion imaging (PI) demonstrated increased perfusion and diffusion-weighted imaging (DWI) showed high signal limited to the left temporoparietal cortex in a 68-year-old man with nonconvulsive status epilepticus. The EEG showed a slow delta-wave focus. The patient recovered and PI, DWI and EEG changes completely resolved. (orig.)

  4. Reversible changes in echo planar perfusion- and diffusion-weighted MRI in status epilepticus

    Energy Technology Data Exchange (ETDEWEB)

    Flacke, S; Keller, E; Urbach, H [Dept. of Radiology, Univ. of Bonn (Germany); Wuellner, U; Hamzei, F [Dept. of Neurology, Univ. of Bonn (Germany)

    2000-02-01

    Perfusion imaging (PI) demonstrated increased perfusion and diffusion-weighted imaging (DWI) showed high signal limited to the left temporoparietal cortex in a 68-year-old man with nonconvulsive status epilepticus. The EEG showed a slow delta-wave focus. The patient recovered and PI, DWI and EEG changes completely resolved. (orig.)

  5. Time-resolved single-shot terahertz time-domain spectroscopy for ultrafast irreversible processes

    Science.gov (United States)

    Zhai, Zhao-Hui; Zhong, Sen-Cheng; Li, Jun; Zhu, Li-Guo; Meng, Kun; Li, Jiang; Liu, Qiao; Peng, Qi-Xian; Li, Ze-Ren; Zhao, Jian-Heng

    2016-09-01

    Pulsed terahertz spectroscopy is suitable for spectroscopic diagnostics of ultrafast events. However, the study of irreversible or single shot ultrafast events requires ability to record transient properties at multiple time delays, i.e., time resolved at single shot level, which is not available currently. Here by angular multiplexing use of femtosecond laser pulses, we developed and demonstrated a time resolved, transient terahertz time domain spectroscopy technique, where burst mode THz pulses were generated and then detected in a single shot measurement manner. The burst mode THz pulses contain 2 sub-THz pulses, and the time gap between them is adjustable up to 1 ns with picosecond accuracy, thus it can be used to probe the single shot event at two different time delays. The system can detect the sub-THz pulses at 0.1 THz-2.5 THz range with signal to noise ratio (SNR) of ˜400 and spectrum resolution of 0.05 THz. System design was described here, and optimizations of single shot measurement of THz pulses were discussed in detail. Methods to improve SNR were also discussed in detail. A system application was demonstrated where pulsed THz signals at different time delays of the ultrafast process were successfully acquired within single shot measurement. This time resolved transient terahertz time domain spectroscopy technique provides a new diagnostic tool for irreversible or single shot ultrafast events where dynamic information can be extracted at terahertz range within one-shot experiment.

  6. Simultaneous single-shot readout of multi-qubit circuits using a traveling-wave parametric amplifier

    Science.gov (United States)

    O'Brien, Kevin

    Observing and controlling the state of ever larger quantum systems is critical for advancing quantum computation. Utilizing a Josephson traveling wave parametric amplifier (JTWPA), we demonstrate simultaneous multiplexed single shot readout of 10 transmon qubits in a planar architecture. We employ digital image sideband rejection to eliminate noise at the image frequencies. We quantify crosstalk and infidelity due to simultaneous readout and control of multiple qubits. Based on current amplifier technology, this approach can scale to simultaneous readout of at least 20 qubits. This work was supported by the Army Research Office.

  7. X-Ray Emission Spectrometer Design with Single-Shot Pump-Probe and Resonant Excitation Capabilities

    Energy Technology Data Exchange (ETDEWEB)

    Spoth, Katherine; /SUNY, Buffalo /SLAC

    2012-08-28

    Core-level spectroscopy in the soft X-ray regime is a powerful tool for the study of chemical bonding processes. The ultrafast, ultrabright X-ray pulses generated by the Linac Coherent Light Source (LCLS) allow these reactions to be studied in greater detail than ever before. In this study, we investigated a conceptual design of a spectrometer for the LCLS with imaging in the non-dispersive direction. This would allow single-shot collection of X-ray emission spectroscopy (XES) measurements with varying laser pump X-ray probe delay or a variation of incoming X-ray energy over the illuminated area of the sample. Ray-tracing simulations were used to demonstrate how the components of the spectrometer affect its performance, allowing a determination of the optimal final design. These simulations showed that the spectrometer's non-dispersive focusing is extremely sensitive to the size of the sample footprint; the spectrometer is not able to image a footprint width larger than one millimeter with the required resolution. This is compatible with a single shot scheme that maps out the laser pump X-ray probe delay in the non-dispersive direction as well as resonant XES applications at normal incidence. However, the current capabilities of the Soft X-Ray (SXR) beamline at the LCLS do not produce the required energy range in a small enough sample footprint, hindering the single shot resonant XES application at SXR for chemical dynamics studies at surfaces. If an upgraded or future beamline at LCLS is developed with lower monochromator energy dispersion the width can be made small enough at the required energy range to be imaged by this spectrometer design.

  8. Accelerator-based single-shot ultrafast transmission electron microscope with picosecond temporal resolution and nanometer spatial resolution

    Science.gov (United States)

    Xiang, D.; Fu, F.; Zhang, J.; Huang, X.; Wang, L.; Wang, X.; Wan, W.

    2014-09-01

    We present feasibility study of an accelerator-based ultrafast transmission electron microscope (u-TEM) capable of producing a full field image in a single-shot with simultaneous picosecond temporal resolution and nanometer spatial resolution. We study key physics related to performance of u-TEMs and discuss major challenges as well as possible solutions for practical realization of u-TEMs. The feasibility of u-TEMs is confirmed through simulations using realistic electron beam parameters. We anticipate that u-TEMs with a product of temporal and spatial resolution beyond 10-19 ms will open up new opportunities in probing matter at ultrafast temporal and ultrasmall spatial scales.

  9. A single-shot nonlinear autocorrelation approach for time-resolved physics in the vacuum ultraviolet spectral range

    International Nuclear Information System (INIS)

    Rompotis, Dimitrios

    2016-02-01

    In this work, a single-shot temporal metrology scheme operating in the vacuum-extreme ultraviolet spectral range has been designed and experimentally implemented. Utilizing an anti-collinear geometry, a second-order intensity autocorrelation measurement of a vacuum ultraviolet pulse can be performed by encoding temporal delay information on the beam propagation coordinate. An ion-imaging time-of-flight spectrometer, offering micrometer resolution has been set-up for this purpose. This instrument enables the detection of a magnified image of the spatial distribution of ions exclusively generated by direct two-photon absorption in the combined counter-propagating pulse focus and thus obtain the second-order intensity autocorrelation measurement on a single-shot basis. Additionally, an intense VUV light source based on high-harmonic generation has been experimentally realized. It delivers intense sub-20 fs Ti:Sa fifth-harmonic pulses utilizing a loose-focusing geometry in a long Ar gas cell. The VUV pulses centered at 161.8 nm reach pulse energies of 1.1 μJ per pulse, while the corresponding pulse duration is measured with a second-order, fringe-resolved autocorrelation scheme to be 18 ± 1 fs on average. Non-resonant, two-photon ionization of Kr and Xe and three-photon ionization of Ne verify the fifth-harmonic pulse intensity and indicate the feasibility of multi-photon VUV pump/VUV probe studies of ultrafast atomic and molecular dynamics. Finally, the extended functionally of the counter-propagating pulse metrology approach is demonstrated by a single-shot VUV pump/VUV probe experiment aiming at the investigation of ultrafast dissociation dynamics of O 2 excited in the Schumann-Runge continuum at 162 nm.

  10. Fast MR imaging for evaluating the pancreaticobiliary system

    International Nuclear Information System (INIS)

    Takehara, Yasuo

    1999-01-01

    Due to physiological movement clinical MR applications for abdominal organs got off to a very slow start compared to MR imaging of other organs. However, with recent cutting-edge hardware technologies such as high performance gradient systems and phased-array capability, as well as software innovations including short TR fast spoiled gradient recalled acquisition in the steady state (GRASS), snapshot imaging such as single shot fast spin echo sequence (SSFSE) and echo planar imaging (EPI), scan times have been further reduced to make breath-hold imaging clinically viable and to enable semi-fluoroscopic, kinematic imaging recognition. The elimination of physiological motion has contributed to the significant improvement in image quality, or more specifically, the physiological motion that had long been problematic has been turned into a source of physiological information about pancreaticobiliary pathologies. In this article, the author reviewed the current status of fast MR technologies for examining pancreaticobiliary pathologies, stressing the functional and physiological aspects of the corresponding anatomy. The technologies included secretin MRCP, which became a powerful tool when combined with kinematic imaging

  11. Magnetic resonance urography in pediatrics: utilization of ultrafast single-shot spin echo sequences

    International Nuclear Information System (INIS)

    Martin, C.; Martin, J.; Duran, C.; Rigol, S.; Rojo, J. C.

    1999-01-01

    To determine the value of magnetic resonance urography (MRU) using ultrafast single-shot (SS) rapid acquisition with relaxation enhancement (RARE) and half-Fourier (HF) SS-RARE (SS-HF-RARE or HASTE) in the evaluation of congenital urinary tract anomalies in pediatric patients, and their possible application as alternatives to intravenous urography (IVU). Eighteen children (11 boys and 7 girls) aged 2 months to 15 years (mean: 5 years) with a total of 19 congenital urinary tract anomalies were studies by MU using SS-RARE and HASTE sequences in a 1 Tesla scanner. All the patients had previously been studies by ultrasound (US) and IVU. Twelve patients required anesthesia. The images were acquired by means of a HASTE sequence with multisection technique (TR, infinite; TE e f, 87 msec; echo train, 128; interval between echoes, 10.9 msec; total acquisition time, 13 sections/12 seconds), and SS-RARE (TR, infinite; TE e f, 1.100 msec; echo train, 240, and acquisition time, 7 seconds). Four radiologists evaluated the images independently; two who reviewed the IV images in consensus and two who reviewed the MRU images in consensus. The images were evaluated to assess the dilatation of the urinary tract and their utility in detecting the level and cause of the obstruction. MRU images revealed the urinary tract dilation, the level of the obstruction and the type of anomaly in 18 patients (100%), while IVU provided this information in only 10 [ sensitivity, 53%, 95% confidence interval (29%, 76%)]. The mean time required for MRU was 20 minutes (range: 7 to 30 minutes), while that of IVU was 1,242 minutes (range: 45 to 1,440 minutes). MRU using ultrafast single-short spin echo sequences is a rapid and effective technique that permits and excellent evaluation of congenital urinary tract anomalies in pediatric patients and does not require the administration of contrast media or ionizing radiation. (Author) 10 refs

  12. Echo-Planar Imaging Based J-Resolved Spectroscopic Imaging for Improved Metabolite Detection in Prostate Cancer

    Science.gov (United States)

    2013-10-01

    prostates. 3) To develop and further optimize the ProFit algorithm to post- process the multi-dimensional MRS data from different prostate pathologies ...used to evaluate prostate anatomy and prostate pathologies for several years. MRI, with its excellent soft-tissue differentiation, provides high...incoherent aliasing while providing data sparsity in a transform domain, such as wavelets , curvelets, etc (76). Incoherent aliasing combined with sparsity

  13. Do Susceptibility Weighted Imaging and Multi-Shot Echo Planar Imaging Optimally Demonstrate and Predict Outcome for Spinal Cord Injury

    Science.gov (United States)

    2017-03-27

    to manufacture, use, or sell any patented invention that may relate to them. Qualified requestors may obtain copies of this report from the...Spinal Injury Association (ASIA) impairment scale A, B, C, or D injury. Inclusion criteria were as follows: (a) age ≥ 18 years old, both genders , (b...morphology of cervical spine fracture. In addition, 15 neurologically intact healthy volunteers with comparable age and gender were recruited to

  14. High-Fidelity Single-Shot Toffoli Gate via Quantum Control.

    Science.gov (United States)

    Zahedinejad, Ehsan; Ghosh, Joydip; Sanders, Barry C

    2015-05-22

    A single-shot Toffoli, or controlled-controlled-not, gate is desirable for classical and quantum information processing. The Toffoli gate alone is universal for reversible computing and, accompanied by the Hadamard gate, forms a universal gate set for quantum computing. The Toffoli gate is also a key ingredient for (nontopological) quantum error correction. Currently Toffoli gates are achieved by decomposing into sequentially implemented single- and two-qubit gates, which require much longer times and yields lower overall fidelities compared to a single-shot implementation. We develop a quantum-control procedure to construct a single-shot Toffoli gate for three nearest-neighbor-coupled superconducting transmon systems such that the fidelity is 99.9% and is as fast as an entangling two-qubit gate under the same realistic conditions. The gate is achieved by a nongreedy quantum control procedure using our enhanced version of the differential evolution algorithm.

  15. Hardware for quasi-single-shot multifrequency magnetic induction tomography (MIT): the Graz Mk2 system

    International Nuclear Information System (INIS)

    Scharfetter, H; Köstinger, A; Issa, S

    2008-01-01

    Magnetic induction tomography (MIT) has been suggested by several groups for the contact-less mapping of the passive electrical properties of tissues via AC magnetic fields in the frequency range between several tens of kHz and several tens of MHz. Multifrequency MIT as an analog to multifrequency EIT has been tried and first image reconstructions have been demonstrated with phantoms. MIT appears to yield comparable images to EIT but offers the advantage of being non-contacting. In the beta-dispersion range of most tissues the method is challenging because the signals are very small and buried in noise. In order to minimize drifts and systematic errors fast data acquisition is therefore pivotal. This paper presents a method for single-shot MIT which allows us to acquire the data for a multifrequency image with an analog bandwidth of 50 kHz–1.5 MHz which covers a good part of the β-dispersion of many tissues. The transmit (TX) coils are simultaneously driven by individual power amplifiers with a multisinus pattern with up to 3 A pp . The amplifiers are configured as current sources so as not to perturb the excitation fields by inappropriately terminated coils. The separation of the different TX channels after reception is achieved by splitting up the carrier frequencies into individual subcarriers with a narrow spacing of at most 300 Hz. In this way every TX coil is identifiable by its own subcarrier but the whole excitation band is contained within a few kHz. The real and imaginary parts of the received signals are extracted efficiently with FFT. The system noise and the sources for low-frequency perturbations are analyzed and characterized

  16. Single-Shot Spectrometry for X-Ray Free-Electron Lasers

    International Nuclear Information System (INIS)

    Yabashi, Makina; Ishikawa, Tetsuya; Hastings, Jerome B.; Zolotorev, Max S.; Mimura, Hidekazu; Yumoto, Hirokatsu; Matsuyama, Satoshi; Yamauchi, Kazuto

    2006-01-01

    An experimental scheme to realize single-shot spectrometry for the diagnostics of x-ray free-electron lasers (XFELs) is presented. The combination of an ultraprecisely figured mirror and a perfect crystal form a simple, high-precision spectrometer that can cover an energy range from a few eV to a hundred eV with high resolution. The application of the spectrometer to determine XFEL pulse widths was investigated theoretically and experimentally. It has been shown that the present system can determine pulse widths from sub-fs to ps in a single shot even for spontaneous radiation. The system can be easily extended to even shorter pulses

  17. Diffusion tensor tractography of the brainstem pyramidal tract; A study on the optimal reduction factor in parallel imaging

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Yun Jung; Park, Jong Bin; Kim, Jae Hyoung; Choi, Byung Se; Jung, Cheol Kyu [Dept. of of Radiology, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2016-08-15

    Parallel imaging mitigates susceptibility artifacts that can adversely affect diffusion tensor tractography (DTT) of the pons depending on the reduction (R) factor. We aimed to find the optimal R factor for DTT of the pons that would allow us to visualize the largest possible number of pyramidal tract fibers. Diffusion tensor imaging was performed on 10 healthy subjects at 3 Tesla based on single-shot echo-planar imaging using the following parameters: b value, 1000 s/mm{sup 2}; gradient direction, 15; voxel size, 2 × 2 × 2 mm{sup 3}; and R factors, 1, 2, 3, 4, and 5. DTT of the right and left pyramidal tracts in the pons was conducted in all subjects. Signal-to-noise ratio (SNR), image distortion, and the number of fibers in the tracts were compared across R factors. SNR, image distortion, and fiber number were significantly different according to R factor. Maximal SNR was achieved with an R factor of 2. Image distortion was minimal with an R factor of 5. The number of visible fibers was greatest with an R factor of 3. R factor 3 is optimal for DTT of the pontine pyramidal tract. A balanced consideration of SNR and image distortion, which do not have the same dependence on the R factor, is necessary for DTT of the pons.

  18. Sjoegren's syndrome of the parotid gland: value of diffusion-weighted echo-planar MRI for diagnosis at an early stage based on MR sialography grading in comparison with healthy volunteers

    International Nuclear Information System (INIS)

    Regier, Marc; Ries, T.; Arndt, C.; Cramer, M.C.; Adam, G.; Habermann, C.R.; Graessner, J.; Reitmeier, F.; Jaehne, M.

    2009-01-01

    To investigate the value of diffusion-weighted echo-planar imaging (DW-EPI) for quantifying functional changes of the parotid gland in Sjoegren's disease and to evaluate whether ADC mapping allows for early diagnosis based on MR sialography grading. Using a DW-EPI sequence at 1.5T (b-factors: 0, 500 and 1000 sec/mm 2 ), the parotid glands of 52 healthy volunteers and 13 patients with histologically verified affection of Sjoegren's disease were examined. All scans were performed prior to and following gustatory stimulation with 5 ml of lemon juice. ADC maps were evaluated by placing an inordinate region-of-interest (ROI) enclosing the entire parotid gland. Sjoegren's disease was graded based on MR sialography findings using a 4-point grading-scale. Statistics included student t-test and kappa-analysis. In healthy volunteers mean ADCs of 1.14 x 10 -3 mm 2 /sec before and 1.2 x 10 -3 mm 2 /sec after stimulation were observed. Higher ADCs were determined for early-stage Sjoegren's disease, averaging 1.22 x 10 -3 mm 2 /sec before and 1.29 x 10 -3 mm 2 /sec after stimulation. Advanced disease revealed significantly lower ADCs (0.97 x 10 -3 mm 2 /sec (p = 0.002) before and 1.01 x 10 -3 mm 2 /sec (p < 0.001) after stimulation). (orig.)

  19. Wavelet Domain Radiofrequency Pulse Design Applied to Magnetic Resonance Imaging.

    Directory of Open Access Journals (Sweden)

    Andrew M Huettner

    Full Text Available A new method for designing radiofrequency (RF pulses with numerical optimization in the wavelet domain is presented. Numerical optimization may yield solutions that might otherwise have not been discovered with analytic techniques alone. Further, processing in the wavelet domain reduces the number of unknowns through compression properties inherent in wavelet transforms, providing a more tractable optimization problem. This algorithm is demonstrated with simultaneous multi-slice (SMS spin echo refocusing pulses because reduced peak RF power is necessary for SMS diffusion imaging with high acceleration factors. An iterative, nonlinear, constrained numerical minimization algorithm was developed to generate an optimized RF pulse waveform. Wavelet domain coefficients were modulated while iteratively running a Bloch equation simulator to generate the intermediate slice profile of the net magnetization. The algorithm minimizes the L2-norm of the slice profile with additional terms to penalize rejection band ripple and maximize the net transverse magnetization across each slice. Simulations and human brain imaging were used to demonstrate a new RF pulse design that yields an optimized slice profile and reduced peak energy deposition when applied to a multiband single-shot echo planar diffusion acquisition. This method may be used to optimize factors such as magnitude and phase spectral profiles and peak RF pulse power for multiband simultaneous multi-slice (SMS acquisitions. Wavelet-based RF pulse optimization provides a useful design method to achieve a pulse waveform with beneficial amplitude reduction while preserving appropriate magnetization response for magnetic resonance imaging.

  20. Ultrafast Single-Shot Optical Oscilloscope based on Time-to-Space Conversion due to Temporal and Spatial Walk-Off Effects in Nonlinear Mixing Crystal

    Science.gov (United States)

    Takagi, Yoshihiro; Yamada, Yoshifumi; Ishikawa, Kiyoshi; Shimizu, Seiji; Sakabe, Shuji

    2005-09-01

    A simple method for single-shot sub-picosecond optical pulse diagnostics has been demonstrated by imaging the time evolution of the optical mixing onto the beam cross section of the sum-frequency wave when the interrogating pulse passes over the tested pulse in the mixing crystal as a result of the combined effect of group-velocity difference and walk-off beam propagation. A high linearity of the time-to-space projection is deduced from the process solely dependent upon the spatial uniformity of the refractive indices. A snap profile of the accidental coincidence between asynchronous pulses from separate mode-locked lasers has been detected, which demonstrates the single-shot ability.

  1. Single-shot LIBS spectral quality for waste particles in open air

    NARCIS (Netherlands)

    Xia, H.; Bakker, M.C.M.

    2015-01-01

    This work investigates the ability of LIBS to produce quality spectra from small particles of concrete demolition waste using single-shot spectra collected in open air. The 2–8?mm materials are rounded river gravel, green glass shards, and plastic flakes. Considered are focal length, air, moisture,

  2. Comparative Study on the Efficacy of Two Regimens of Single-Shot ...

    African Journals Online (AJOL)

    Objective: To assess and compare the satisfaction and efficacy of two regimens of single-shot spinal blocks for the relief of labor pain in women who present in active phase of labour. Design: A prospective randomised single-blind observational study. Setting: Labour ward of Kenyatta National Hospital, Nairobi. Subjects: All ...

  3. Quantitative single shot and spatially resolved plasma wakefield diagnostics

    CERN Document Server

    Kasim, Muhammad Firmansyah; Ceurvorst, Luke; Levy, Matthew C; Ratan, Naren; Sadler, James; Bingham, Robert; Burrows, Philip N; Trines, Raoul; Wing, Matthew; Norreys, Peter

    2015-01-01

    Diagnosing plasma conditions can give great advantages in optimizing plasma wakefield accelerator experiments. One possible method is that of photon acceleration. By propagating a laser probe pulse through a plasma wakefield and extracting the imposed frequency modulation, one can obtain an image of the density modulation of the wakefield. In order to diagnose the wakefield parameters at a chosen point in the plasma, the probe pulse crosses the plasma at oblique angles relative to the wakefield. In this paper, mathematical expressions relating the frequency modulation of the laser pulse and the wakefield density profile of the plasma for oblique crossing angles are derived. Multidimensional particle-in-cell simulation results presented in this paper confirm that the frequency modulation profiles and the density modulation profiles agree to within 10%. Limitations to the accuracy of the measurement are discussed in this paper. This technique opens new possibilities to quantitatively diagnose the plasma wakefie...

  4. From single-shot towards general work extraction in a quantum thermodynamic framework

    International Nuclear Information System (INIS)

    Gemmer, Jochen; Anders, Janet

    2015-01-01

    This paper considers work extraction from a quantum system to a work storage system (or weight) following Horodecki and Oppenheim (2013 Nat. Commun. 4 2059). An alternative approach is here developed that relies on the comparison of subspace dimensions without a need to introduce thermo-majorization used previously. Optimal single shot work for processes where a weight transfers from (a) a single energy level to another single energy level is then re-derived. In addition we discuss the final state of the system after work extraction and show that the system typically ends in its thermal state, while there are cases where the system is only close to it. The work of formation in the single level transfer setting is also re-derived. The approach presented now allows the extension of the single shot work concept to work extraction (b) involving multiple final levels of the weight. A key conclusion here is that the single shot work for case (a) is appropriate only when a resonance of a particular energy is required. When wishing to identify ‘work extraction’ with finding the weight in a specific available energy or any higher energy a broadening of the single shot work concept is required. As a final contribution we consider transformations of the system that (c) result in general weight state transfers. Introducing a transfer-quantity allows us to formulate minimum requirements for transformations to be at all possible in a thermodynamic framework. We show that choosing the free energy difference of the weight as the transfer-quantity one recovers various single shot results including single level transitions (a), multiple final level transitions (b), and recent results on restricted sets of multi-level to multi-level weight transfers. (paper)

  5. Diffusion tensor imaging in children and adolescents with tuberous sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Karadag, Demet [Institute of Diagnostic and Interventional Radiology, Friedrich Schiller University, Department of Paediatric Radiology, Jena (Germany); Kirikkale Yuksek Ihtisas Hospital, Department of Radiology, Kirirkale (Turkey); Mentzel, Hans-J.; Loebel, Ulrike; Reichenbach, Juergen R.; Kaiser, Werner A. [Institute of Diagnostic and Interventional Radiology, Friedrich Schiller University, Department of Paediatric Radiology, Jena (Germany); Guellmar, Daniel [Institute of Diagnostic and Interventional Radiology, Friedrich Schiller University, Department of Paediatric Radiology, Jena (Germany); Friedrich Schiller University, Biomagnetic Centre, Clinic of Neurology, Jena (Germany); Rating, Tina; Brandl, Ulrich [Friedrich Schiller University, Department of Paediatric Neurology, Jena (Germany)

    2005-10-01

    Tuberous sclerosis (TS) is characterised by benign hamartomatous lesions in many organs. Diffusion tensor imaging (DTI) can detect microstructural changes in pathological processes. To determine apparent diffusion coefficient (ADC) and fractional anisotropy (FA) maps in children with TS and to investigate the diffusion properties in cortical tubers, white-matter lesions, perilesional white matter, and contralateral normal-appearing white matter, and to compare the results with ADC and FA maps of normal age- and sex-matched volunteers. Seven children and adolescents (age range 2-20 years) suffering from TS were included. MRI was performed on a 1.5-T scanner using a transmit/receive coil with T1-W and T2-W spin-echo and FLAIR sequences. DT images were acquired by using a single-shot echo-planar pulse sequence. Diffusion gradients were applied in six different directions with a b value of 1,000 s/mm{sup 2}. ADC was higher in cortical tubers than in the corresponding cortical location of controls. ADC values were higher and FA values were lower in white-matter lesions and perilesional white matter than in both the contralateral normal-appearing white matter of patients and in controls. There were no significant differences for both ADC and FA values in the normal-appearing white matter of patients with TS compared to controls. DTI provides important information about cortical tubers, white-matter abnormalities, and perilesional white matter in patients with TS. (orig.)

  6. Multi-slice echo-planar spectroscopic MR imaging provides both global and local metabolite measures in multiple sclerosis

    DEFF Research Database (Denmark)

    Mathiesen, Henrik Kahr; Tscherning, Thomas; Sorensen, Per Soelberg

    2005-01-01

    MR spectroscopy (MRS) provides information about neuronal loss or dysfunction by measuring decreases in N-acetyl aspartate (NAA), a metabolite widely believed to be a marker of neuronal viability. In multiple sclerosis (MS), whole-brain NAA (WBNAA) has been suggested as a marker of disease...... progression and treatment efficacy in treatment trials, and the ability to measure NAA loss in specific brain regions early in the evolution of this disease may have prognostic value. Most spectroscopic studies to date have been limited to single voxels or nonlocalized measurements of WBNAA only...

  7. High-speed single-shot optical focusing through dynamic scattering media with full-phase wavefront shaping

    Science.gov (United States)

    Hemphill, Ashton S.; Shen, Yuecheng; Liu, Yan; Wang, Lihong V.

    2017-11-01

    In biological applications, optical focusing is limited by the diffusion of light, which prevents focusing at depths greater than ˜1 mm in soft tissue. Wavefront shaping extends the depth by compensating for phase distortions induced by scattering and thus allows for focusing light through biological tissue beyond the optical diffusion limit by using constructive interference. However, due to physiological motion, light scattering in tissue is deterministic only within a brief speckle correlation time. In in vivo tissue, this speckle correlation time is on the order of milliseconds, and so the wavefront must be optimized within this brief period. The speed of digital wavefront shaping has typically been limited by the relatively long time required to measure and display the optimal phase pattern. This limitation stems from the low speeds of cameras, data transfer and processing, and spatial light modulators. While binary-phase modulation requiring only two images for the phase measurement has recently been reported, most techniques require at least three frames for the full-phase measurement. Here, we present a full-phase digital optical phase conjugation method based on off-axis holography for single-shot optical focusing through scattering media. By using off-axis holography in conjunction with graphics processing unit based processing, we take advantage of the single-shot full-phase measurement while using parallel computation to quickly reconstruct the phase map. With this system, we can focus light through scattering media with a system latency of approximately 9 ms, on the order of the in vivo speckle correlation time.

  8. Single-shot readout of accumulation mode Si/SiGe spin qubits using RF reflectometry

    Science.gov (United States)

    Volk, Christian; Martins, Frederico; Malinowski, Filip; Marcus, Charles M.; Kuemmeth, Ferdinand

    Spin qubits based on gate-defined quantum dots are promising systems for realizing quantum computation. Due to their low concentration of nuclear-spin-carrying isotopes, Si/SiGe heterostructures are of particular interest. While high fidelities have been reported for single-qubit and two-qubit gate operations, qubit initialization and measurement times are relatively slow. In order to develop fast read-out techniques compatible with the operation of spin qubits, we characterize double and triple quantum dots confined in undoped Si/Si0.7Ge0.3 heterostructures using accumulation and depletion gates and a nearby RF charge sensor dot. We implement a RF reflectometry technique that allows single-shot charge read-out at integration times on the order of a few μs. We show our recent advancement towards implementing spin qubits in these structures, including spin-selective single-shot read-out.

  9. Single-shot and single-spot measurement of laser ablation threshold for carbon nanotubes

    OpenAIRE

    Lednev, Vasily N.; Pershin, Sergey M.; Obraztsova, Elena D.; Kudryashov, Sergey I.; Bunkin, Alexey F.

    2013-01-01

    A simple and convenient procedure for single-shot, single-spot ablation threshold measurement has been developed. It is based on the employment of cylindrical lens to obtain elliptical Gaussian laser spot. The ablated spot chords which are parallel to the minor axis were measured across the spot major axis which is proportional to the fluence cross-section thus providing wide range dependence of damaged spot size versus fluence in one spot measurement. For both conventional and new-developed ...

  10. Infrared single shot diagnostics for the longitudinal profile of the electron bunches at FLASH

    International Nuclear Information System (INIS)

    Delsim-Hashemi, Hossein

    2008-09-01

    The longitudinal profile of electron bunches plays an important role in the design of single-pass free electron lasers and future linear e + e - colliders. For the free electron laser FLASH in Hamburg, a longitudinal compression scheme is used which results in an asymmetric longitudinal bunch profile with a 'spike'. This 'spike', which has a very high peak current, is used in a high-gain SASE-FEL process to produce high intensity (about 70 μJ) femtosecond photon pulses in the XUV wavelength range. The required high peak current of the electron bunch is realized by confining a large number of electrons in a width, measured in time units, of few tens of femtosecond, making the diagnostics of such bunches a challenge. Furthermore, the operation of facilities such as FLASH shows that single-shot diagnostics is indispensable. It is intuitive to use a time domain method to measure the electron bunch length. However, when the structures present in the bunch profile fall in the femtoseconds range, this is beyond the resolution of time-resolved methods developed so far. In this thesis, a wavelength-domain technique is described that can fulfill both requirements of single shot and high resolution reaching to the femtoseconds range. The amount of charge that is confined in a typical length of several femtoseconds (FWHM of the spike) can be determined by a novel single-shot spectrometer that resolves the coherent radiation (e.g. coherent transition radiation) in the far-infrared and mid-infrared range. Furthermore the extension of this single-shot spectroscopy to shorter wavelengths reaching the near-infrared, makes it possible to investigate the presence of structures in the bunch profile that might correlate or anti-correlate to the SASE intensity. (orig.)

  11. Infrared single shot diagnostics for the longitudinal profile of the electron bunches at FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Delsim-Hashemi, Hossein

    2008-09-15

    The longitudinal profile of electron bunches plays an important role in the design of single-pass free electron lasers and future linear e{sup +}e{sup -} colliders. For the free electron laser FLASH in Hamburg, a longitudinal compression scheme is used which results in an asymmetric longitudinal bunch profile with a 'spike'. This 'spike', which has a very high peak current, is used in a high-gain SASE-FEL process to produce high intensity (about 70 {mu}J) femtosecond photon pulses in the XUV wavelength range. The required high peak current of the electron bunch is realized by confining a large number of electrons in a width, measured in time units, of few tens of femtosecond, making the diagnostics of such bunches a challenge. Furthermore, the operation of facilities such as FLASH shows that single-shot diagnostics is indispensable. It is intuitive to use a time domain method to measure the electron bunch length. However, when the structures present in the bunch profile fall in the femtoseconds range, this is beyond the resolution of time-resolved methods developed so far. In this thesis, a wavelength-domain technique is described that can fulfill both requirements of single shot and high resolution reaching to the femtoseconds range. The amount of charge that is confined in a typical length of several femtoseconds (FWHM of the spike) can be determined by a novel single-shot spectrometer that resolves the coherent radiation (e.g. coherent transition radiation) in the far-infrared and mid-infrared range. Furthermore the extension of this single-shot spectroscopy to shorter wavelengths reaching the near-infrared, makes it possible to investigate the presence of structures in the bunch profile that might correlate or anti-correlate to the SASE intensity. (orig.)

  12. Sjoegren's syndrome of the parotid gland: value of diffusion-weighted echo-planar MRI for diagnosis at an early stage based on MR sialography grading in comparison with healthy volunteers

    Energy Technology Data Exchange (ETDEWEB)

    Regier, Marc; Ries, T.; Arndt, C.; Cramer, M.C.; Adam, G.; Habermann, C.R. [Universitaetsklinikum Hamburg-Eppendorf (Germany). Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie; Graessner, J. [Siemens AG, Hamburg (Germany). Medical Solutions; Reitmeier, F.; Jaehne, M. [Universitaetsklinikum Hamburg-Eppendorf (Germany). Klinik und Poliklinik fuer Hals-, Nasen- und Ohrenheilkunde

    2009-03-15

    To investigate the value of diffusion-weighted echo-planar imaging (DW-EPI) for quantifying functional changes of the parotid gland in Sjoegren's disease and to evaluate whether ADC mapping allows for early diagnosis based on MR sialography grading. Using a DW-EPI sequence at 1.5T (b-factors: 0, 500 and 1000 sec/mm{sup 2}), the parotid glands of 52 healthy volunteers and 13 patients with histologically verified affection of Sjoegren's disease were examined. All scans were performed prior to and following gustatory stimulation with 5 ml of lemon juice. ADC maps were evaluated by placing an inordinate region-of-interest (ROI) enclosing the entire parotid gland. Sjoegren's disease was graded based on MR sialography findings using a 4-point grading-scale. Statistics included student t-test and kappa-analysis. In healthy volunteers mean ADCs of 1.14 x 10{sup -3} mm{sup 2} /sec before and 1.2 x 10{sup -3} mm{sup 2} /sec after stimulation were observed. Higher ADCs were determined for early-stage Sjoegren's disease, averaging 1.22 x 10{sup -3} mm{sup 2} /sec before and 1.29 x 10{sup -3} mm{sup 2} /sec after stimulation. Advanced disease revealed significantly lower ADCs (0.97 x 10{sup -3} mm{sup 2} /sec (p = 0.002) before and 1.01 x 10{sup -3} mm{sup 2} /sec (p < 0.001) after stimulation). (orig.)

  13. Contrast-enhanced CT and diffusion-weighted MR imaging: Performance as a prognostic factor in patients with pancreatic ductal adenocarcinoma

    International Nuclear Information System (INIS)

    Fukukura, Yoshihiko; Takumi, Koji; Higashi, Michiyo; Shinchi, Hiroyuki; Kamimura, Kiyohisa; Yoneyama, Tomohide; Tateyama, Akihiro

    2014-01-01

    Objective: To determine whether contrast enhancement of CT and apparent diffusion coefficient on diffusion-weighted MR imaging are important parameters that can predict outcomes for patients with pancreatic ductal adenocarcinoma. Materials and methods: Ninety-two patients with histologically confirmed pancreatic ductal adenocarcinoma who underwent quadriphasic CT (including unenhanced, pancreatic parenchymal, portal venous and delayed phases) and fat-suppressed single-shot echo-planar diffusion-weighted MR imaging at 3.0 T were retrospectively analyzed to investigate prognostic factors. Overall survival curves were drawn using the Kaplan–Meier method. Effects on survival of variables including age, sex, tumor location, tumor size, TNM stage, carbohydrate antigen 19-9, carcinoembryonic antigen, treatment, tumor contrast enhancement and apparent diffusion coefficient values were analyzed in univariate analysis using the log-rank test. Variables were analyzed in multivariate analyses using the Cox proportional hazards regression model. Results: Median survival for the entire patient population was 18.2 months. Higher contrast enhancement during all phases was associated with significantly longer overall survival (P < 0.001 for all phases). The difference in overall survival between groups divided by median apparent diffusion coefficient value was not significant (P = 0.672). TNM stage (P = 0.026) and tumor contrast enhancement on CT (P = 0.027) were significantly related to survival in multivariate analysis. Conclusions: Poor enhancement of pancreatic adenocarcinomas on enhanced CT is associated with reduced patient survival

  14. Contrast-enhanced CT and diffusion-weighted MR imaging: Performance as a prognostic factor in patients with pancreatic ductal adenocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Fukukura, Yoshihiko, E-mail: fukukura@m.kufm.kagoshima-u.ac.jp [Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan); Takumi, Koji [Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan); Higashi, Michiyo [Department of Human Pathology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan); Shinchi, Hiroyuki [Department of Surgical Oncology and Digestive Surgery, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan); Kamimura, Kiyohisa; Yoneyama, Tomohide; Tateyama, Akihiro [Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan)

    2014-04-15

    Objective: To determine whether contrast enhancement of CT and apparent diffusion coefficient on diffusion-weighted MR imaging are important parameters that can predict outcomes for patients with pancreatic ductal adenocarcinoma. Materials and methods: Ninety-two patients with histologically confirmed pancreatic ductal adenocarcinoma who underwent quadriphasic CT (including unenhanced, pancreatic parenchymal, portal venous and delayed phases) and fat-suppressed single-shot echo-planar diffusion-weighted MR imaging at 3.0 T were retrospectively analyzed to investigate prognostic factors. Overall survival curves were drawn using the Kaplan–Meier method. Effects on survival of variables including age, sex, tumor location, tumor size, TNM stage, carbohydrate antigen 19-9, carcinoembryonic antigen, treatment, tumor contrast enhancement and apparent diffusion coefficient values were analyzed in univariate analysis using the log-rank test. Variables were analyzed in multivariate analyses using the Cox proportional hazards regression model. Results: Median survival for the entire patient population was 18.2 months. Higher contrast enhancement during all phases was associated with significantly longer overall survival (P < 0.001 for all phases). The difference in overall survival between groups divided by median apparent diffusion coefficient value was not significant (P = 0.672). TNM stage (P = 0.026) and tumor contrast enhancement on CT (P = 0.027) were significantly related to survival in multivariate analysis. Conclusions: Poor enhancement of pancreatic adenocarcinomas on enhanced CT is associated with reduced patient survival.

  15. Single-shot secure quantum network coding on butterfly network with free public communication

    Science.gov (United States)

    Owari, Masaki; Kato, Go; Hayashi, Masahito

    2018-01-01

    Quantum network coding on the butterfly network has been studied as a typical example of quantum multiple cast network. We propose a secure quantum network code for the butterfly network with free public classical communication in the multiple unicast setting under restricted eavesdropper’s power. This protocol certainly transmits quantum states when there is no attack. We also show the secrecy with shared randomness as additional resource when the eavesdropper wiretaps one of the channels in the butterfly network and also derives the information sending through public classical communication. Our protocol does not require verification process, which ensures single-shot security.

  16. Selective visualization of pelvic splanchnic nerve and pelvic plexus using readout-segmented echo-planar diffusion-weighted magnetic resonance neurography: A preliminary study in healthy male volunteers

    Energy Technology Data Exchange (ETDEWEB)

    Yamashita, Rikiya, E-mail: rickdom@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Isoda, Hiroyoshi, E-mail: sayuki@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Arizono, Shigeki, E-mail: arizono@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Furuta, Akihiro, E-mail: akihirof@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Ohno, Tsuyoshi, E-mail: goohno@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging, Osaka Red Cross Hospital, 5-30 Fudegasaki-cho, Tennoji-ku, Osaka, 543-8555 (Japan); Ono, Ayako, E-mail: onoayako@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Murata, Katsutoshi, E-mail: katsutoshi.murata@siemens.com [Siemens Healthcare Japan KK, Gate City Osaki West Tower, 11-1 Osaki 1-Chome, Shinagawa-ku, Tokyo 141-8644 (Japan); Togashi, Kaori, E-mail: ktogashi@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan)

    2017-01-15

    Highlights: • RS-EPI DW-MRN has a potential to selectively depict the pelvic parasympathetic nerve. • The nervous visibility showed a moderate correlation with the image artifact level. • Our method could help preserving function after pelvic nerve-preserving surgery. - Abstract: Purpose: To evaluate the potential of readout-segmented echo-planar diffusion-weighted magnetic resonance neurography (RS-EPI DW-MRN) for the selective visualization of pelvic splanchnic nerve and pelvic plexus in healthy male volunteers. Materials and methods: Institutional review board approval and written informed consent were obtained. RS-EPI DW-MRN images were acquired from thirteen healthy male volunteers aged 25–48 years between September 2013 and December 2013. For RS-EPI DW-MRN, the following parameters were used: spatial resolution, 1.1 × 1.1 × 2.5 mm; b-value, 250 s/mm{sup 2}; number of readout-segments, seven; and acquisition time, 7 min 45 s. For qualitative assessment, two abdominal radiologists independently evaluated the visibility of the pelvic splanchnic nerves and pelvic plexuses bilaterally in each subject on oblique coronal thin-slab 10-mm-thick maximum intensity projection images and scored it with a 4-point grading scale (excellent, good, fair, poor). Both readers scored twice at 6-month intervals. Inter-observer and intra-observer variability were evaluated using Cohen’s quadratically weighted κ statistics. Image artifact level was scored on a 4-point grading scale by other two abdominal radiologists in order to evaluate the correlation between the nerve visibility and the severity of imaging artifacts using the Spearman’s correlation coefficient. Results: Qualitative grading showed the following success rate (number of nerves qualitatively scored as excellent or good divided by total number of nerves): reader 1 (first set), 73% (19/26); reader 2 (first set), 77% (20/26); reader 1 (second set), 81% (21/26); and reader 2 (second set), 77% (20

  17. Diffusion tensor imaging in spinal cord compression

    International Nuclear Information System (INIS)

    Wang, Wei; Qin, Wen; Hao, Nanxin; Wang, Yibin; Zong, Genlin

    2012-01-01

    Background Although diffusion tensor imaging has been successfully applied in brain research for decades, several main difficulties have hindered its extended utilization in spinal cord imaging. Purpose To assess the feasibility and clinical value of diffusion tensor imaging and tractography for evaluating chronic spinal cord compression. Material and Methods Single-shot spin-echo echo-planar DT sequences were scanned in 42 spinal cord compression patients and 49 healthy volunteers. The mean values of the apparent diffusion coefficient and fractional anisotropy were measured in region of interest at the cervical and lower thoracic spinal cord. The patients were divided into two groups according to the high signal on T2WI (the SCC-HI group and the SCC-nHI group for with or without high signal). A one-way ANOVA was used. Diffusion tensor tractography was used to visualize the morphological features of normal and impaired white matter. Results There were no statistically significant differences in the apparent diffusion coefficient and fractional anisotropy values between the different spinal cord segments of the normal subjects. All of the patients in the SCC-HI group had increased apparent diffusion coefficient values and decreased fractional anisotropy values at the lesion level compared to the normal controls. However, there were no statistically significant diffusion index differences between the SCC-nHI group and the normal controls. In the diffusion tensor imaging maps, the normal spinal cord sections were depicted as fiber tracts that were color-encoded to a cephalocaudal orientation. The diffusion tensor images were compressed to different degrees in all of the patients. Conclusion Diffusion tensor imaging and tractography are promising methods for visualizing spinal cord tracts and can provide additional information in clinical studies in spinal cord compression

  18. MR neurography of the median nerve at 3.0 T: Optimization of diffusion tensor imaging and fiber tractography

    International Nuclear Information System (INIS)

    Guggenberger, Roman; Eppenberger, Patrick; Markovic, Daniel; Nanz, Daniel; Chhabra, Avneesh; Pruessmann, Klaas P.; Andreisek, Gustav

    2012-01-01

    Objectives: The purpose of this study was to systematically assess the optimal b-value and reconstruction parameters for DTI and fiber tractography of the median nerve at 3.0 T. Methods: Local ethical board approved study with 45 healthy volunteers (15 men, 30 women; mean age, 41 ± 3.4 years) who underwent DTI of the right wrist at 3.0 T. A single-shot echo-planar-imaging sequence (TR/TE 10123/40 ms) was acquired at four different b-values (800, 1000, 1200, and 1400 s/mm 2 ). Two independent readers performed post processing and fiber-tractography. Fractional anisotropy (FA) maps were calculated. Fiber tracts of the median nerve were generated using four different algorithms containing different FA thresholds and different angulation tolerances. Data were evaluated quantitatively and qualitatively. Results: Tracking algorithms using a minimum FA threshold of 0.2 and a maximum angulation of 10° were significantly better than other algorithms. Fiber tractography generated significantly longer fibers in DTI acquisitions with higher b-values (1200 and 1400 s/mm 2 versus 800 s/mm 2 ; p 2 (p 2 for DTI of the median nerve at 3.0 T. Optimal reconstruction parameters for fiber tractography should encompass a minimum FA threshold of 0.2 and a maximum angulation tolerance of 10.

  19. Anti-spoof touchless 3D fingerprint recognition system using single shot fringe projection and biospeckle analysis

    Science.gov (United States)

    Chatterjee, Amit; Bhatia, Vimal; Prakash, Shashi

    2017-08-01

    Fingerprint is a unique, un-alterable and easily collected biometric of a human being. Although it is a 3D biological characteristic, traditional methods are designed to provide only a 2D image. This touch based mapping of 3D shape to 2D image losses information and leads to nonlinear distortions. Moreover, as only topographic details are captured, conventional systems are potentially vulnerable to spoofing materials (e.g. artificial fingers, dead fingers, false prints, etc.). In this work, we demonstrate an anti-spoof touchless 3D fingerprint detection system using a combination of single shot fringe projection and biospeckle analysis. For fingerprint detection using fringe projection, light from a low power LED source illuminates a finger through a sinusoidal grating. The fringe pattern modulated because of features on the fingertip is captured using a CCD camera. Fourier transform method based frequency filtering is used for the reconstruction of 3D fingerprint from the captured fringe pattern. In the next step, for spoof detection using biospeckle analysis a visuo-numeric algorithm based on modified structural function and non-normalized histogram is proposed. High activity biospeckle patterns are generated because of interaction of collimated laser light with internal fluid flow of the real finger sample. This activity reduces abruptly in case of layered fake prints, and is almost absent in dead or fake fingers. Furthermore, the proposed setup is fast, low-cost, involves non-mechanical scanning and is highly stable.

  20. Functional magnetic resonance imaging by visual stimulation

    International Nuclear Information System (INIS)

    Nishimura, Yukiko; Negoro, Kiyoshi; Morimatsu, Mitsunori; Hashida, Masahiro

    1996-01-01

    We evaluated functional magnetic resonance images obtained in 8 healthy subjects in response to visual stimulation using a conventional clinical magnetic resonance imaging system with multi-slice spin-echo echo planar imaging. Activation in the visual cortex was clearly demonstrated by the multi-slice experiment with a task-related change in signal intensity. In addition to the primary visual cortex, other areas were also activated by a complicated visual task. Multi-slice spin-echo echo planar imaging offers high temporal resolution and allows the three-dimensional analysis of brain function. Functional magnetic resonance imaging provides a useful noninvasive method of mapping brain function. (author)

  1. Diffusion weighted MR imaging of brachial plexus diseases

    International Nuclear Information System (INIS)

    Okinaga, Shuji; Korenaga, Tateo; Tekemura, Atsushi; Tajiri, Yasuhito; Kawano, Ken-Ichi

    2010-01-01

    Diffusion weighted image (DWI) can specifically give running of nerve fibers as they have diffusion anisotropic property and DW whole body imaging with background body signal suppression (DWIBS) procedure, which being capable of imaging cervical and lumber nerve roots, is thus suggested to be useful for diagnosis of diseases related to brachial plexus (BP). The purpose of the present study is to confirm the usefulness of DWIBS by comparison of its images of the normal and sick plexuses. Subjects are 5 normal healthy males (27-36 y), 29 patients (19 M/10 F, 7-73 y) with BP diseases (10 cases of external injury, 6 of obstetric palsy, 2 of paralysis by dysfunctional position, 6 by Schwannoma, 2 by metastasis of breast cancer and 3 by radiation) and, to see the diagnostic specificity, 9 patients (M 7/F 2, 15-64 y) with severely reduced hand force by nervous causes other than BP ones. MRI with Philips Gyroscan INTERA 1.5T machine is conducted for DWIBS by DWI with single shot EPI (echo planar imaging) with the coil of either sensitivity encoding (SENSE) Cardiac, Flex-M or -S. Images are reconstructed 3D by a radiological technician possessing no information concerning patient's conditions, with Philips software Soap-bubble tool on the workstation, and are then evaluated by a radiologist and an orthopedist separately. It is found that BP disorders by injury, obstetric palsy and tumors, of which diagnosis has been difficult hitherto, can be imaged either negatively or positively depending on their history. In radiation paralysis, only 1/3 cases give a reduced signal intensity in the whole BP. DWIBS will be a new diagnostic mean for systemic peripheral nerve diseases as well as BP ones. (T.T.)

  2. Comparison of qualitative and quantitative evaluation of diffusion-weighted MRI and chemical-shift imaging in the differentiation of benign and malignant vertebral body fractures.

    Science.gov (United States)

    Geith, Tobias; Schmidt, Gerwin; Biffar, Andreas; Dietrich, Olaf; Dürr, Hans Roland; Reiser, Maximilian; Baur-Melnyk, Andrea

    2012-11-01

    The objective of our study was to compare the diagnostic value of qualitative diffusion-weighted imaging (DWI), quantitative DWI, and chemical-shift imaging in a single prospective cohort of patients with acute osteoporotic and malignant vertebral fractures. The study group was composed of patients with 26 osteoporotic vertebral fractures (18 women, eight men; mean age, 69 years; age range, 31 years 6 months to 86 years 2 months) and 20 malignant vertebral fractures (nine women, 11 men; mean age, 63.4 years; age range, 24 years 8 months to 86 years 4 months). T1-weighted, STIR, and T2-weighted sequences were acquired at 1.5 T. A DW reverse fast imaging with steady-state free precession (PSIF) sequence at different delta values was evaluated qualitatively. A DW echo-planar imaging (EPI) sequence and a DW single-shot turbo spin-echo (TSE) sequence at different b values were evaluated qualitatively and quantitatively using the apparent diffusion coefficient. Opposed-phase sequences were used to assess signal intensity qualitatively. The signal loss between in- and opposed-phase images was determined quantitatively. Two-tailed Fisher exact test, Mann-Whitney test, and receiver operating characteristic analysis were performed. Sensitivities, specificities, and accuracies were determined. Qualitative DW-PSIF imaging (delta = 3 ms) showed the best performance for distinguishing between benign and malignant fractures (sensitivity, 100%; specificity, 88.5%; accuracy, 93.5%). Qualitative DW-EPI (b = 50 s/mm(2) [p = 1.00]; b = 250 s/mm(2) [p = 0.50]) and DW single-shot TSE imaging (b = 100 s/mm(2) [p = 1.00]; b = 250 s/mm(2) [p = 0.18]; b = 400 s/mm(2) [p = 0.18]; b = 600 s/mm(2) [p = 0.39]) did not indicate significant differences between benign and malignant fractures. DW-EPI using a b value of 500 s/mm(2) (p = 0.01) indicated significant differences between benign and malignant vertebral fractures. Quantitative DW-EPI (p = 0.09) and qualitative opposed-phase imaging (p = 0

  3. Optimization And Single-Shot Characterization Of Ultrashort Thz Pulses From A Laser Wakefield Accelerator

    International Nuclear Information System (INIS)

    Plateau, G.R.; Matlis, N.H.; van Tilborg, J.; Geddes, C.G.R.; Toth, Cs.; Schroeder, C.B.; Leemans, W.P.

    2009-01-01

    We present spatiotemporal characterization of μJ-class ultrashort THz pulses generated from a laser wakefield accelerator (LWFA). Accelerated electrons, resulting from the interaction of a high-intensity laser pulse with a plasma, emit high-intensity THz pulses as coherent transition radiation. Such high peak-power THz pulses, suitable for high-field (MV/cm) pump-probe experiments, also provide a non-invasive bunch-length diagnostic and thus feedback for the accelerator. The characterization of the THz pulses includes energy measurement using a Golay cell, 2D sign-resolved electro-optic measurement and single-shot spatiotemporal electric-field distribution retrieval using a new technique, coined temporal electric-field cross-Correlation (TEX). All three techniques corroborate THz pulses of ∼ 5 μJ, with peak fields of 100's of kV/cm and ∼ 0.4 ps rms duration.

  4. Single-Shot Quantum Nondemolition Detection of Individual Itinerant Microwave Photons

    Science.gov (United States)

    Besse, Jean-Claude; Gasparinetti, Simone; Collodo, Michele C.; Walter, Theo; Kurpiers, Philipp; Pechal, Marek; Eichler, Christopher; Wallraff, Andreas

    2018-04-01

    Single-photon detection is an essential component in many experiments in quantum optics, but it remains challenging in the microwave domain. We realize a quantum nondemolition detector for propagating microwave photons and characterize its performance using a single-photon source. To this aim, we implement a cavity-assisted conditional phase gate between the incoming photon and a superconducting artificial atom. By reading out the state of this atom in a single shot, we reach an external (internal) photon-detection fidelity of 50% (71%), limited by transmission efficiency between the source and the detector (75%) and the coherence properties of the qubit. By characterizing the coherence and average number of photons in the field reflected off the detector, we demonstrate its quantum nondemolition nature. We envisage applications in generating heralded remote entanglement between qubits and for realizing logic gates between propagating microwave photons.

  5. Single-shot and single-spot measurement of laser ablation threshold for carbon nanotubes

    International Nuclear Information System (INIS)

    Lednev, Vasily N; Pershin, Sergey M; Bunkin, Alexey F; Obraztsova, Elena D; Kudryashov, Sergey I

    2013-01-01

    A simple and convenient procedure for single-shot, single-spot ablation threshold measurement is developed. It is based on the employment of cylindrical lens to obtain an elliptical Gaussian laser spot. The ablated spot chords that are parallel to the minor axis are measured across the spot major axis, which is proportional to the fluence cross-section, thus providing wide range dependence of damaged spot size versus fluence in one spot measurement. For both conventional and newly developed procedures the ablation threshold for typical Nd:YAG laser parameters (1064 nm, 10 ns) is measured as 50 ± 5 mJ cm -2 , which is one order of magnitude lower than that for bulk graphite.

  6. Method for single-shot measurement of picosecond laser pulse-lengths without electronic time dispersion

    International Nuclear Information System (INIS)

    Kyrala, G.A.

    1987-01-01

    A two-source shear pattern recording is proposed as a method for single-shot measurement of the pulse shape from nearly monochromatic sources whose pulse lengths are shorter than their coherence times. The basis of this method relies on the assertion that if two identical electromagnetic pulses are recombined with a time delay greater than the sum of their pulse widths, the recordable spatial pattern has no fringes in it. At an arbitrary delay, translated into an actual spatial recording position, the recorded modulated intensity will sample the corresponding laser intensity at that delay time, but with a modulation due to the coherence function of the electromagnetic pulse. Two arrangements are proposed for recording the pattern. The principles, the design parameters, and the methodologies of these arrangements are presented. Resolutions of the configurations and their limitations are given as well

  7. Single-shot electro-optic experiments for electron bunch diagnostics at Tsinghua Accelerator Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Wei; Du, Yingchao; Yan, Lixin; Hua, Jianfei; Zhang, Zhen; Zhou, Zheng [Accelerator Laboratory, Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle and Radiation Imaging, Tsinghua University, Ministry of Education, Beijing 100084 (China); Huang, Wenhui, E-mail: huangwh@mail.tsinghua.edu.cn [Accelerator Laboratory, Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle and Radiation Imaging, Tsinghua University, Ministry of Education, Beijing 100084 (China); Tang, Chuanxiang [Accelerator Laboratory, Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle and Radiation Imaging, Tsinghua University, Ministry of Education, Beijing 100084 (China); Li, Ming [Institute of Applied Electronics, China Academy of Engineering Physics, Mianyang 621900 (China)

    2016-10-21

    The electro-optic (EO) technique detects the Coulomb electric field distribution of relativistic electron bunches to obtain the associated longitudinal profile. This diagnostic method allows the direct time-resolved single-shot measurement and thus the real-time monitoring of the bunch profile and beam arrival time in a non-destructive way with sub-picosecond temporal resolution. In this paper, we report the measurement of the longitudinal profile of an electron bunch through electro-optic spectral decoding detection, in which the bunch profile is encoded into the spectra of the linearly chirped laser pulse. The experimental setup and measurement results of a 40 MeV electron bunch are presented, with a temporal profile length of 527 fs rms (~1.24 ps FWHM) and a beam arrival time jitter of 471 fs rms. Temporal resolution and future experimental improvement are also discussed.

  8. Radiography simulation on single-shot dual-spectrum X-ray for cargo inspection system

    International Nuclear Information System (INIS)

    Gil, Youngmi; Oh, Youngdo; Cho, Moohyun; Namkung, Won

    2011-01-01

    We propose a method to identify materials in the dual energy X-ray (DeX) inspection system. This method identifies materials by combining information on the relative proportions T of high-energy and low-energy X-rays transmitted through the material, and the ratio R of the attenuation coefficient of the material when high-energy are used to that when low energy X-rays are used. In Monte Carlo N-Particle Transport Code (MCNPX) simulations using the same geometry as that of the real container inspection system, this T vs. R method successfully identified tissue-equivalent plastic and several metals. In further simulations, the single-shot mode of operating the accelerator led to better distinguishing of materials than the dual-shot system.

  9. 3 ns single-shot read-out in a quantum dot-based memory structure

    International Nuclear Information System (INIS)

    Nowozin, T.; Bimberg, D.; Beckel, A.; Lorke, A.; Geller, M.

    2014-01-01

    Fast read-out of two to six charges per dot from the ground and first excited state in a quantum dot (QD)-based memory is demonstrated using a two-dimensional electron gas. Single-shot measurements on modulation-doped field-effect transistor structures with embedded InAs/GaAs QDs show read-out times as short as 3 ns. At low temperature (T = 4.2 K) this read-out time is still limited by the parasitics of the setup and the device structure. Faster read-out times and a larger read-out signal are expected for an improved setup and device structure

  10. A versatile diffractive maskless lithography for single-shot and serial microfabrication.

    Science.gov (United States)

    Jenness, Nathan J; Hill, Ryan T; Hucknall, Angus; Chilkoti, Ashutosh; Clark, Robert L

    2010-05-24

    We demonstrate a diffractive maskless lithographic system that is capable of rapidly performing both serial and single-shot micropatterning. Utilizing the diffractive properties of phase holograms displayed on a spatial light modulator, arbitrary intensity distributions were produced to form two and three dimensional micropatterns/structures in a variety of substrates. A straightforward graphical user interface was implemented to allow users to load templates and change patterning modes within the span of a few minutes. A minimum resolution of approximately 700 nm is demonstrated for both patterning modes, which compares favorably to the 232 nm resolution limit predicted by the Rayleigh criterion. The presented method is rapid and adaptable, allowing for the parallel fabrication of microstructures in photoresist as well as the fabrication of protein microstructures that retain functional activity.

  11. Single-shot beam size measurements using visible-light interferometry at CESR

    Energy Technology Data Exchange (ETDEWEB)

    Wang, S.T., E-mail: sw565@cornell.edu [Cornell Laboratory for Accelerator-based Science and Education, Cornell University, Ithaca, NY 14853 (United States); Holtzapple, R. [Physics Department, California Polytechnic State University, San Luis Obispo, CA 93407 (United States); Rubin, D.L. [Cornell Laboratory for Accelerator-based Science and Education, Cornell University, Ithaca, NY 14853 (United States)

    2017-03-01

    A new primary mirror for a visible-light beam size monitor (vBSM) was designed and installed in the Cornell Electron-Positron Storage Ring (CESR). The vertical angular acceptance of the mirror was doubled to allow double-slit interferometry with large slit separation (>12 mm). In addition, the diffraction associated with the first generation mirror has been eliminated. The resolution of the vertical beam size measurements has been dramatically improved but is ultimately limited by the beam motion. Two fast-response detectors, a Photomultiplier Tube (PMT) array and a gated camera, were employed to study the beam motion. The advantages and limitations of both devices are discussed in this paper. The gated camera was also used to measure single-shot beam width and motion of each bunch in a multi-bunch train. We measured significantly more horizontal motion of electron as compared to positron bunch trains in otherwise identical machine condition. This difference may be a signature for the difference between electron cloud build-up for positron bunch trains versus ions effects characteristic of electron bunch trains. - Highlights: • A new extraction mirror for synchrotron radiation was designed and installed in CESR. • The sensitivity of interferometer was increased and the diffraction effect was eliminated. • Two fast-response detectors were employed to study the effect of beam motion. • First time single-shot bunch-by-bunch horizontal beam size measurements using interferometry was observed from gated camera. • The difference in single bunch horizontal dynamics was observed between a positron and an electron train.

  12. Comparison of ropivacaine and bupivacaine as single-shot epidural anaesthesia for orthopaedic surgery

    International Nuclear Information System (INIS)

    Riaz, A.; Khan, A.S.

    2015-01-01

    To compare the efficacy and side-effects of 0.5% ropivacaine with that of 0.5% bupivacaine when used for single-shot epidural anaesthesia for orthopaedic surgery. Design: Randomized controlled trial. Place and Duration of Study: Department of Anesthesiology, Combined Military Hospital Rawalpindi, over a period of eight months from June 2013 to January 2014. Patients and Methods: The study was carried out in 60 ASA physical status I, II or III patients undergoing elective lower extremity orthopedic surgery. Two groups of 30 patients each received single-shot epidural anaesthesia either with ropivacaine 0.5% (ropivacaine group) or bupivacaine 0.5% (bupivacaine group). Onset, time for maximum height and median height of sensory block was assessed as well as time to two segment recession. Modified Bromage scale was used for motor blockade. Total duration of motor block and common side effects were also recorded. Results: The patients in both groups were similar in age, height, weight, gender and ASA status. There was no significant difference in onset of sensory block and time for maximum height of sensory block. The median heighest level of sensory block was T6 (T5-T8) for ropivacaine group and T5 (T4-T7) for bupivacaine group. Time for two segment regression and duration of sensory block were also comparable for both groups. The total duration of motor block was significantly more in bupivacaine group (159 min vs 134.2 min, p< 0.001). Modified Bromage scale was also significantly higher in bupivacaine group (2.86 vs 1.96 min, p<0.001). Side effects like hypotension, bradycardia, nausea, vomiting and shivering were similar in both groups. Conclusion: Epidural administration of 0.5% ropivacaine provided effective and good quality anaesthesia. Motor blockade was of less duration as compared to equivalent dose of 0.5% bupivacaine, which may offer potential benefit of early patient mobilization after orthopaedic surgery. (author)

  13. Diffusion tensor imaging of the normal prostate at 3 Tesla

    International Nuclear Information System (INIS)

    Guerses, Bengi; Kabakci, Neslihan; Kovanlikaya, Arzu; Firat, Zeynep; Bayram, Ali; Kovanlikaya, Ilhami; Ulud, Aziz M.

    2008-01-01

    The aim of this study was to assess the feasibility of diffusion tensor imaging (DTI) of the prostate and to determine normative fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values of healthy prostate with a 3-Tesla magnetic resonance imaging (MRI) system. Thirty volunteers with a mean age of 28 (25-35) years were scanned with a 3-Tesla MRI (Intera Achieva; Philips, The Netherlands) system using a six-channel phased array coil. Initially, T2-weighted turbo spin-echo (TSE) axial images of the prostate were obtained. In two subjects, a millimetric hypointense signal change was detected in the peripheral zones on T2-weighted TSE images. These two subjects were excluded from the study. DTI with single-shot echo-planar imaging (ssEPI) was performed in the remaining 28 subjects. ADC and FA values were measured using the manufacturer supplied software by positioning 9-pixel ROIs on each zone. Differences between parameters of the central and peripheral zones were assessed. Mean ADC value of the central (1.220 ± 0.271 x 10 -3 mm 2 /s) was found to be significantly lower when compared with the peripheral gland (1.610 ± 0.347 x 10 -3 mm 2 /s) (P < 0.01). Mean FA of the central gland was significantly higher (0.26), compared with the peripheral gland (0.16) (P < 0.01). This study shows the feasibility of prostate DTI with a 3-Tesla MR system and the normative FA and ADC values of peripheral and central zones of the normal prostate. The results are compatible with the microstructural organization of the gland. (orig.)

  14. Modelling single shot damage thresholds of multilayer optics for high-intensity short-wavelength radiation sources

    NARCIS (Netherlands)

    Loch, R.A.; Sobierajski, R.; Louis, Eric; Bosgra, J.; Bosgra, J.; Bijkerk, Frederik

    2012-01-01

    The single shot damage thresholds of multilayer optics for highintensity short-wavelength radiation sources are theoretically investigated, using a model developed on the basis of experimental data obtained at the FLASH and LCLS free electron lasers. We compare the radiation hardness of commonly

  15. Single-shot Thomson scattering on argon plasmas created by the Microwave Plasma Torch; evidence for a new plasma class

    NARCIS (Netherlands)

    Mullen, van der J.J.A.M.; Sande, van de M.J.; Vries, de N.; Broks, B.H.P.; Iordanova, E.I.; Gamero, A.; Torres, J.; Sola, A.

    2007-01-01

    To determine the fine-structure size of plasmas created by a Microwave Plasma Torch (MPT), single-shot Thomson scattering (TS) measurements were performed. The aim was to find a solution for the long-standing discrepancy between experiments and Global Plasma Models (GPMs). Since these GPMs are based

  16. A TV camera system for digitizing single shot oscillograms at sweep rate of 0.1 ns/cm

    International Nuclear Information System (INIS)

    Kienlen, M.; Knispel, G.; Miehe, J.A.; Sipp, B.

    1976-01-01

    A TV camera digitizing system associated with a 5 GHz photocell-oscilloscope apparatus allows the digitizing of single shot oscillograms; with an oscilloscope sweep rate of 0.1 ns/cm an accuracy on time measurements of 4 ps is obtained [fr

  17. Diffusion-weighted MR imaging of thyroid nodules

    International Nuclear Information System (INIS)

    Bozgeyik, Zulkif; Coskun, Sonay; Ogur, Erkin; Dagli, A.F.; Ozkan, Yusuf; Sahpaz, Fatih

    2009-01-01

    The purpose of our study was to determine the diagnostic role of diffusion-weighted imaging (DWI) in the differentiating of malignant and benign thyroid nodules by using fine needle aspiration biopsy cytology criteria as a reference standard. The apparent diffusion coefficient (ADC) values of the normal-looking thyroid parenchyma were also evaluated both in normal patients and in patients with nodules. Between March 2007 and February 2008, 76 consecutive patients with ultrasound-diagnosed thyroid nodules and 20 healthy subjects underwent diffusion-weighted MR imaging by using single-shot spin echo, echo planar imaging. A total of 93 nodules were included in the study using the following b factors 100, 200, and 300 mm 2 /s. ADC values of thyroid nodules and normal area in all subjects were calculated and compared using suitable statistical analysis. Mean ADC values for malignant and benign nodules were 0.96±0.65 x 10 -3 and 3.06±0.71 x 10 -3 mm 2 /s. for b-300 factor, 0.56±0.43 x 10 -3 and 1.80±0.60 x 10 -3 mm 2 /s for b-200, and 0.30±0.20 x 10 -3 and 1.15±0.43 x 10 -3 mm 2 /s, for b-300, respectively. Mean ADC values of malignant nodules were lower than benign nodules. There were significant differences in ADC values between benign and malignant nodules. ADC values among normal-appearing thyroid parenchyma of patients and normal-appearing thyroid parenchyma of healthy subjects were insignificant at all b factors. Benign nodules have higher ADC values than malignant ones. DWI may be helpful in differentiating malign and benign thyroid nodules. (orig.)

  18. Characterization of Soft Tissue Tumors by Diffusion-Weighted Imaging

    International Nuclear Information System (INIS)

    Pekcevik, Yeliz; Kahya, Mehmet Onur; Kaya, Ahmet

    2015-01-01

    Diffusion-weighted imaging (DWI) is a noninvasive method for investigation of tumor histological content. It has been applied for some musculoskeletal tumors and reported to be useful. The aim of the present study was to prospectively evaluate the apparent diffusion coefficient (ADC) values of benign and malignant soft tissue tumors and to determine if ADC can help differentiate these tumors. DWI was performed on 25 histologically proven soft tissue masses. It was obtained with a single-shot echo-planar imaging technique using a 1.5T magnetic resonance (MR) machine. The mean ADC values were calculated. We grouped soft tissue tumors as benign cystic, benign solid or mixed, malignant cystic and malignant solid or mixed tumors and compared mean ADC values between these groups. There was only one patient with a malignant cystic tumor and was not included in the statistical analysis. The median ADC values of benign and malignant tumors were 2.31 ± 1.29 and 0.90 ± 0.70 (median ± interquartile range), respectively. The mean ADC values were different between benign and malignant tumors (P = 0.031). Benign cystic tumors had significantly higher ADC values than benign solid or mixed tumors and malignant solid or mixed tumors (p values were < 0.001 and 0.003, respectively). Malignant solid or mixed tumors had lower ADC values than benign solid or mixed tumors (P = 0.02). Our preliminary results have shown that although there is some overlap between benign and malignant tumors, adding DWI, MR imaging to routine soft tissue tumor protocols may improve diagnostic accuracy

  19. Single-shot femtosecond laser ablation of gold surface in air and isopropyl alcohol

    Science.gov (United States)

    Kudryashov, S. I.; Saraeva, I. N.; Lednev, V. N.; Pershin, S. M.; Rudenko, A. A.; Ionin, A. A.

    2018-05-01

    Single-shot IR femtosecond-laser ablation of gold surfaces in ambient air and liquid isopropyl alcohol was studied by scanning electron microscopy characterization of crater topographies and time-resolved optical emission spectroscopy of ablative plumes in regimes, typical for non-filamentary and non-fragmentation laser production of nanoparticle sols. Despite one order of magnitude shorter (few nanoseconds) lifetimes and almost two orders of magnitude lower intensities of the quenched ablative plume emission in the alcohol ambient at the same peak laser fluence, craters for the dry and wet conditions appeared with rather similar nanofoam-like spallative topographies and the same thresholds. These facts envision the underlying surface spallation as one of the basic ablation mechanisms relevant for both dry and wet advanced femtosecond laser surface nano/micro-machining and texturing, as well as for high-throughput femtosecond laser ablative production of colloidal nanoparticles by MHz laser-pulse trains via their direct nanoscale jetting from the nanofoam in air and fluid environments.

  20. Anterior chamber configuration in patients with glaucoma: MR gonioscopy evaluation with half-Fourier single-shot RARE sequence and microscopy coil.

    Science.gov (United States)

    Tanitame, Keizo; Sasaki, Ko; Sone, Takashi; Uyama, Shinji; Sumida, Masumi; Ichiki, Toshio; Ito, Katsuhide

    2008-10-01

    The purpose of the study was to determine the accuracy of half-Fourier single-shot rapid acquisition with relaxation enhancement high-spatial-resolution magnetic resonance (MR) imaging performed with a microscopy coil in the diagnosis of narrow anterior chamber angle in patients with glaucoma. Slit-lamp biomicroscopy served as the reference standard. The institutional review board approved this study, and written informed consent was obtained from the 20 recruited patients. There was excellent agreement between MR gonioscopy and slit-lamp biomicroscopy in the classification of anterior chamber angles as narrow or open (kappa = 0.89 [95% confidence interval: 0.69, 1.10]). MR gonioscopy has substantial potential as a technique used to evaluate glaucoma. (c) RSNA, 2008.

  1. Diffusion-weighted MRI of the Prostate: Advantages of Zoomed EPI with Parallel-transmit-accelerated 2D-selective Excitation Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Thierfelder, Kolja M.; Scherr, Michael K.; Weiss, Jakob; Mueller-Lisse, Ullrich G.; Theisen, Daniel [Ludwig-Maximilians-University Hospital Munich, Institute for Clinical Radiology, Munich (Germany); Notohamiprodjo, Mike; Nikolaou, Konstantin [Ludwig-Maximilians-University Hospital Munich, Institute for Clinical Radiology, Munich (Germany); University Hospital Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Dietrich, Olaf [Ludwig-Maximilians-University Hospital Munich, Josef Lissner Laboratory for Biomedical Imaging, Institute for Clinical Radiology, Munich (Germany); Pfeuffer, Josef [Siemens Healthcare, Application Development, Erlangen (Germany)

    2014-12-15

    The purpose of our study was to evaluate the use of 2D-selective, parallel-transmit excitation magnetic resonance imaging (MRI) for diffusion-weighted echo-planar imaging (pTX-EPI) of the prostate, and to compare it to conventional, single-shot EPI (c-EPI). The MRI examinations of 35 patients were evaluated in this prospective study. PTX-EPI was performed with a TX-acceleration factor of 1.7 and a field of view (FOV) of 150 x 90 mm{sup 2}, whereas c-EPI used a full FOV of 380 x 297 mm{sup 2}. Two readers evaluated three different aspects of image quality on 5-point Likert scales. To quantify distortion artefacts, maximum diameters and prostate volume were determined for both techniques and compared to T2-weighted imaging. The zoomed pTX-EPI was superior to c-EPI with respect to overall image quality (3.39 ± 0.62 vs 2.45 ± 0.67) and anatomic differentiability (3.29 ± 0.65 vs 2.41 ± 0.65), each with p < 0.0001. Artefacts were significantly less severe in pTX-EPI (0.93 ± 0.73 vs 1.49 ± 1.08), p < 0.001. The quantitative analysis yielded a higher agreement of pTX-EPI with T2-weighted imaging than c-EPI with respect to coronal (ICCs: 0.95 vs 0.93) and sagittal (0.86 vs 0.73) diameters as well as prostate volume (0.94 vs 0.92). Apparent diffusion coefficient (ADC) values did not differ significantly between the two techniques (p > 0.05). Zoomed pTX-EPI leads to substantial improvements in diffusion-weighted imaging (DWI) of the prostate with respect to different aspects of image quality and severity of artefacts. (orig.)

  2. Diffusion-weighted magnetic resonance imaging in autoimmune pancreatitis

    International Nuclear Information System (INIS)

    Taniguchi, Takao; Kobayashi, Hisato; Nishikawa, Koji; Iida, Etsushi; Michigami, Yoshihiro; Morimoto, Emiko; Yamashita, Rikiya; Miyagi, Ken; Okamoto, Motozumi

    2009-01-01

    The aim of this study was to investigate the usefulness of diffusion-weighted magnetic resonance imaging (DWI MRI) for the diagnosis and evaluation of autoimmune pancreatitis (AIP). A total of 4 consecutive patients with AIP, 5 patients with chronic alcoholic pancreatitis (CP), and 13 patients without pancreatic disease (controls) were studied. DWI was performed in the axial plane with spin-echo echo-planar imaging single-shot sequence. Apparent diffusion coefficients (ADCs) were measured in circular regions of interest in the pancreas. In AIP patients, abdominal MRI was performed before, and 2-4 weeks after steroid treatment. Follow-up study was performed chronologically for up to 11 months in two patients. The correlation between ADCs of the pancreas and the immunoglobulin G4 (IgG4) index (serum IgG4 value/serum IgG4 value before steroid treatment) was evaluated. In the AIP patients, DWI of the pancreas showed high signal intensity, and the ADCs of the pancreas (mean±standard deviation (SD): 0.97±0.18 x 10 -3 mm 2 /s) were significantly lower than those in patients with CP (1.45±0.10 x 10 -3 mm 2 /s) or the controls (1.45±0.16 x 10 -3 mm 2 /s) (Mann-Whitney U-test, P s =-0.80, P<0.05). Autoimmune pancreatitis showed high signal intensity on DWI, which improved after steroid treatment. ADCs reflected disease activity. Thus, diffusion-weighted MRI might be useful for diagnosing AIP, determining the affected area, and evaluating the effect of treatment. (author)

  3. Diagnostic performance of conventional diffusion weighted imaging and diffusion tensor imaging for the liver fibrosis and inflammation

    International Nuclear Information System (INIS)

    Tosun, Mesude; Inan, Nagihan; Sarisoy, Hasan Tahsin; Akansel, Gur; Gumustas, Sevtap; Gürbüz, Yeşim; Demirci, Ali

    2013-01-01

    Objective: To evaluate the diagnostic accuracy of liver apparent diffusion coefficient (ADC) measured with conventional diffusion-weighted imaging (CDI) and diffusion tensor imaging (DTI) for the diagnosis of liver fibrosis and inflammation. Materials and methods: Thirty-seven patients with histologic diagnosis of chronic viral hepatitis and 34 healthy volunteers were included in this prospective study. All patients and healthy volunteers were examined by 3 T MRI. CDI and DTI were performed using a breath-hold single-shot echo-planar spin echo sequence with b factors of 0 and 1000 s/mm 2 . ADCs were obtained with CDI and DTI. Histopathologically, fibrosis of the liver parenchyma was classified with the use of a 5-point scale (0–4) and inflammation was classified with use of a 4-point scale (0–3) in accordance with the METAVIR score. Quantitatively, signal intensity and the ADCs of the liver parenchyma were compared between patients stratified by fibrosis stage and inflammation grade. Results: With a b factor of 1000 s/mm 2 , the signal intensity of the cirrhotic livers was significantly higher than those of the normal volunteers. In addition, ADCs reconstructed from CDI and DTI of the patients were significantly lower than those of the normal volunteers. Liver ADC values inversely correlated with fibrosis and inflammation but there was only statistically significant for inflammatory grading. CDI performed better than DTI for the diagnosis of fibrosis and inflammation. Conclusion: ADC values measured with CDI and DTI may help in the detection of liver fibrosis. They may also give contributory to the inflammatory grading, particularly in distinguishing high from low grade

  4. Diagnostic performance of conventional diffusion weighted imaging and diffusion tensor imaging for the liver fibrosis and inflammation

    Energy Technology Data Exchange (ETDEWEB)

    Tosun, Mesude, E-mail: mesude.tosun@kocaeli.edu.tr [Department of Radiology, School of Medicine, University of Kocaeli (Turkey); Inan, Nagihan, E-mail: inannagihan@ekolay.net [Department of Radiology, School of Medicine, University of Kocaeli (Turkey); Sarisoy, Hasan Tahsin, E-mail: htssarisoy@yahoo.com [Department of Radiology, School of Medicine, University of Kocaeli (Turkey); Akansel, Gur, E-mail: gakansel@gmail.com [Department of Radiology, School of Medicine, University of Kocaeli (Turkey); Gumustas, Sevtap, E-mail: svtgumustas@hotmail.com [Department of Radiology, School of Medicine, University of Kocaeli (Turkey); Gürbüz, Yeşim, E-mail: yesimgurbuz2002@yahoo.com [Department of Pathology, School of Medicine, University of Kocaeli (Turkey); Demirci, Ali, E-mail: alidemirci@kocaeli.edu.tr [Department of Radiology, School of Medicine, University of Kocaeli (Turkey)

    2013-02-15

    Objective: To evaluate the diagnostic accuracy of liver apparent diffusion coefficient (ADC) measured with conventional diffusion-weighted imaging (CDI) and diffusion tensor imaging (DTI) for the diagnosis of liver fibrosis and inflammation. Materials and methods: Thirty-seven patients with histologic diagnosis of chronic viral hepatitis and 34 healthy volunteers were included in this prospective study. All patients and healthy volunteers were examined by 3 T MRI. CDI and DTI were performed using a breath-hold single-shot echo-planar spin echo sequence with b factors of 0 and 1000 s/mm{sup 2}. ADCs were obtained with CDI and DTI. Histopathologically, fibrosis of the liver parenchyma was classified with the use of a 5-point scale (0–4) and inflammation was classified with use of a 4-point scale (0–3) in accordance with the METAVIR score. Quantitatively, signal intensity and the ADCs of the liver parenchyma were compared between patients stratified by fibrosis stage and inflammation grade. Results: With a b factor of 1000 s/mm{sup 2}, the signal intensity of the cirrhotic livers was significantly higher than those of the normal volunteers. In addition, ADCs reconstructed from CDI and DTI of the patients were significantly lower than those of the normal volunteers. Liver ADC values inversely correlated with fibrosis and inflammation but there was only statistically significant for inflammatory grading. CDI performed better than DTI for the diagnosis of fibrosis and inflammation. Conclusion: ADC values measured with CDI and DTI may help in the detection of liver fibrosis. They may also give contributory to the inflammatory grading, particularly in distinguishing high from low grade.

  5. Diffusion tensor imaging of the spinal cord at 1.5 and 3.0 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, C. [Radiologische Universitaetsklinik, Tuebingen (Germany). Sektion fuer Experimentelle Radiologie; CNR-INFM CRS-Soft, La Sapienza-Univ. Roma (Italy); Enrico Fern Center, Roma (Italy); Boss, A.; Martirosian, P.; Steidle, G.; Schick, F. [Radiologische Universitaetsklinik, Tuebingen (Germany). Sektion fuer Experimentelle Radiologie; Lindig, T.M. [Enrico Fern Center, Roma (Italy); Radiologische Universitaetsklinik, Tuebingen (Germany). Sektion fuer Experimentelle Kernspinresonanz des ZNS; Universitaetsklinikum Tuebingen (Germany). Zentrum fuer Neurologie und Hertie-Inst. fuer klinische Hirnforschung; Maetzler, W. [Universitaetsklinikum Tuebingen (Germany). Zentrum fuer Neurologie und Hertie-Inst. fuer klinische Hirnforschung; Claussen, C.D. [Radiologische Universitaetsklinik, Tuebingen (Germany). Abt. fuer Radiologische Diagnostik; Klose, U. [Radiologische Universitaetsklinik, Tuebingen (Germany). Sektion fuer Experimentelle Kernspinresonanz des ZNS

    2007-03-15

    Purpose: The feasibility of highly resolved diffusion tensor imaging (DTI) of the human cervical spinal cord was tested on a clinical MR unit operating at 3.0 Tesla. DTI parametrical maps and signal-to-noise ratios (SNRs) were compared to results recorded at 1.5 Tesla. Materials and Methods: Eight healthy volunteers and one patient participated in the study. A transverse oriented single-shot ECG-triggered echo-planar imaging (EPI) sequence with double spin-echo diffusion preparation was applied for highly resolved DTI of the spinal cord. The signal yield, fractional anisotropy (FA), and mean diffusivity (MD) were compared for both field strengths. The clinical applicability of the protocol was also tested in one patient with amyotrophic lateral sclerosis (ALS) at 3.0 T. Results: A mean increase in SNR of 95.7 {+-} 4.6% was found at 3.0 Tesla compared to 1.5 Tesla. Improved quality of the DTI parametrical maps was observed at higher field strength (p < 0.02). Comparable FA and MD (reported in units of 10 - 3 mm2/s) values were computed in the dorsal white matter at both field strengths (1.5 T: FA = 0.75 {+-} 0.08, MD = 0.84 {+-} 0.12, 3.0 T: FA = 0.74 {+-} 0.04, MD = 0.93 {+-} 0.14). The DTI images exhibited diagnostic image quality in the patient. At the site of the diseased corticospinal tract, a decrease of 46.0 {+-} 3.8% in FA (0.40 {+-} 0.03) and an increase of 50.3 {+-} 5.6% in MD (1.40 {+-} 0.05) were found in the ALS patient. (orig.)

  6. Diffusion tensor imaging of the spinal cord at 1.5 and 3.0 Tesla

    International Nuclear Information System (INIS)

    Rossi, C.; Boss, A.; Martirosian, P.; Steidle, G.; Schick, F.; Lindig, T.M.; Radiologische Universitaetsklinik, Tuebingen; Universitaetsklinikum Tuebingen; Maetzler, W.; Claussen, C.D.; Klose, U.

    2007-01-01

    Purpose: The feasibility of highly resolved diffusion tensor imaging (DTI) of the human cervical spinal cord was tested on a clinical MR unit operating at 3.0 Tesla. DTI parametrical maps and signal-to-noise ratios (SNRs) were compared to results recorded at 1.5 Tesla. Materials and Methods: Eight healthy volunteers and one patient participated in the study. A transverse oriented single-shot ECG-triggered echo-planar imaging (EPI) sequence with double spin-echo diffusion preparation was applied for highly resolved DTI of the spinal cord. The signal yield, fractional anisotropy (FA), and mean diffusivity (MD) were compared for both field strengths. The clinical applicability of the protocol was also tested in one patient with amyotrophic lateral sclerosis (ALS) at 3.0 T. Results: A mean increase in SNR of 95.7 ± 4.6% was found at 3.0 Tesla compared to 1.5 Tesla. Improved quality of the DTI parametrical maps was observed at higher field strength (p < 0.02). Comparable FA and MD (reported in units of 10 - 3 mm2/s) values were computed in the dorsal white matter at both field strengths (1.5 T: FA = 0.75 ± 0.08, MD = 0.84 ± 0.12, 3.0 T: FA 0.74 ± 0.04, MD = 0.93 ± 0.14). The DTI images exhibited diagnostic image quality in the patient. At the site of the diseased corticospinal tract, a decrease of 46.0 ± 3.8% in FA (0.40 ± 0.03) and an increase of 50.3 ± 5.6% in MD (1.40 ± 0.05) were found in the ALS patient. (orig.)

  7. The single-shot opto-digitizer; L'optoechantillonneur monocoup

    Energy Technology Data Exchange (ETDEWEB)

    Nail, M.; Gibert, Ph. [CEA/DAM-Ile de France, Dept. de Conception et Realisation des Experimentations (DCRE), 91 - Bruyeres-le-Chatel (France); CEA/DAM-Ile de France, Dept. Laser Puissance, DLP, 91 - Bruyeres-Le-Chatel (France)

    2000-07-01

    Laser-plasma experiments need to measure signals provided either by X-ray, photonic or neutronic detector. The measurement should have 50 GHz bandwidth and up to several hundred of Giga-Hertz for sub picosecond plasmas. For this purpose, a 35 GHz single shot opto-digitizer (10 ps risetime) has been studied and built. The device is made up of a 50 ohms microstrip propagation line, periodically lined by 100 sampled gates. The propagation line is long enough to measure a 400 ps duration. The sampling rate is 250 Gsa/s (every 4 ps). The sampled gates are made with fast recombining photo-material and turn on by a subpicosecond laser pulse which is synchronized exactly with the analysed phenomena. Every gate is recording to a storing capacitor. After the recording, every capacitor charge is needed to built the signal that was displayed on the propagation line. The dynamic range of measurement is 47 for the entire device. The device can measure positive or negative signals from 1.5 to 70 Volts. To increase the bandwidth, two another kinds of opto-digitizer were studied: one is a buried stripline with 56 GHz band width, the other a 70 GHz coplanar transmission line. For the purpose of subpicosecond plasmas, a 30 coplanar waveguide opto-digitizer was studied. Characteristics are as followed: window of measurement 40 ps, sampling rate 1 ps, bandwidth 230 GHz. Finally, a bundle of optical fibers was used to propagate the laser beam on semiconductor gates. If the gates are lighted at the same time, i.e. if the optical fibers have the same length, we get a simultaneous addressing. By using different lengths of optical fibers, we can do a sequential addressing. So, the sampling rate becomes a combination of the distance between two adjacent sampled channels, and the difference in length of optical fibers. (author)

  8. Characterization of chondroid matrix-forming sarcomas: gadolinium-enhanced and diffusion weighted MR imaging

    International Nuclear Information System (INIS)

    Cheng Kebin; Zhang Jing; Qu Hui; Zhang Wei; Liang Wei; Li Xiaosong; Cheng Xiaoguang; Gong Lihua

    2010-01-01

    Objective: To study the Gadolinium-enhanced MRI and diffusion weighted imaging (DWI) characteristics of the chondroid matrix-forming sarcomas. Methods: Contrast-enhanced MRI and DWI were performed in 14 cases of chondroid matrix-forming sarcomas (10 chondrosarcomas, 4 chondroblastic osteosarcomas) and 13 cases of other types of osteosarcomas. DWI was obtained with a single-shot echo-planar imaging (EPI) sequence using a 1.5 T MR imager with two different b values of 0 and 700 s/mm 2 . The apparent diffusion coefficient (ADC) values were obtained in GE Functiontool software. The contrast-enhancement pattern was evaluated and the ADC values of chondroid matrix-forming sarcomas was compared with that of other types of osteosareoma. Independent sample t-test was performed to evaluate the difference of ADC values between the group of chondroid matrix-forming sarcoma and the group of other types of osteosarcoma. In addition, nonparametric test was used to assess the difference of ADC values between the chondrosarcoma and the chondroblastic osteosarcoma. P value less than 0.05 was considered to represent a statistical significance. Results: For 14 cases of chondroid matrix-forming sarcomas, peripheral enhancement was found in all cases, septonodular enhancement was identified in 12 cases. While 13 cases of other types of osteosarcomas demonstrated heterogeneous enhancement. The mean ADC value of chondroid matrix-forming sarcomas [(2.56±0.35) x 10 -3 mm 2 /s] was significantly higher than that of other types of osteosarcoma [(1.16 ± 0.20) x 10 -3 mm 2 /s] (t=12.704, P<0.01). There was no significant difference in the ADC value between the chondrosarcoma and the chondroblastic osteosarcoma (Z=0.507, P=0.959). Conclusion: Contrast-enhanced MRI and DWI can improve differentiation between chondroid matrix-forming sarcomas and other types of osteosarcomas. (authors)

  9. Role of EPI in diagnosing cavernous hemangioma and small HCC : comparison with fast T2-weighted MR Imaging

    International Nuclear Information System (INIS)

    Kim, Suk; Lee, Jun Woo; Kim, Chang Won; Jung, Hyun Woo; Choi, Sang Yoel; Lee, Suck Hong; Kim, Byung Soo

    1998-01-01

    The purpose of this study is to compare single-shot echo-planar MR imaging (EPI) with breath-hold fast T2-weighted imaging (HASTE or Turbo spin-echo T2WI) for evaluation of the role of EPI in distinguishing small hepatocellular carcinoma from cavernous hemangioma. We retrospectively evaluated MR images of 35 patients (21 cases of small HCC and 14 cases of cavernous hemangioma). EPI and breath-hold fast T2WI images were obtained and compared on the basis of lesion detection sensitivity, lesion-to-liver signal intensity ratio (SIR), contrast ratio (CR), and lesion-to-liver contrast to noise ratio (CNR). For the detection of small HCC, the sensitivity of EPI and breath-hold fast T2WI were equal in 14 of 21 cases (71.4%). The detection sensitivity of cavernous hemangioma with EPI and breath-hold fast T2WI was 100 % (14/14). Mean SIR on breath-hold fast T2WI was 2.02 ± 0.45 for small HCC and 3.65 ± 0.97 for cavernous hemangioma; on EPI, the corresponding figures were 2.91 ± 0.57 for cavernous hemangioma; On EPI, the figures obtained were 2.27 ± 0.52 and 6.26 ± 2.19, respectively. Mean CNR on breath-hold fast T2WI was 14.24 ± 4.098 for small HCC and 50.28 ± 10.96 for cavernous hemangioma, while on EPI, the corresponding figures were 13.84 ± 3.02 and 45.44 ± 11.21. In detecting focal hepatic mass, the sensitivity of EPI and breath-hold fast T2WI are comparable for the diagnosis of small HCC and cavernous hemangioma, EPI can provided additional information. (author). 20 refs., 2 tabs., 4 figs

  10. Analysis of the diffusion tensor imaging parameters of a normal cervical spinal cord in a healthy population.

    Science.gov (United States)

    Wei, Liang-Feng; Wang, Shou-Sen; Zheng, Zhao-Cong; Tian, Jun; Xue, Liang

    2017-05-01

    Diffusion tensor imaging (DTI) shows great advantage in the diagnosis of brain diseases, including cervical spinal cord (CSC) disease. This study aims to obtain the normal values of the DTI parameters for a healthy population and to establish a baseline for CSC disease diagnosis using DTI. A total of 36 healthy adults were subjected to magnetic resonance imaging (MRI) for the entire CSC using the Siemens 3.0 T MR System. Sagittal DTI acquisition was carried out with a single-shot spin-echo echo-planar imaging (EPI) sequence along 12 non-collinear directions. Fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values were determined at different cervical levels using a region of interest (ROI) method, following which they were correlated with parameters, like age and sex. Further, diffusion tensor tracking (DTT) was carried out to reconstruct the white matter fiber bundles of the CSC. The full and complete fiber bundle structure of a normal CSC was confirmed in both the T2-weighted and DTI images. The FA and ADC values were significantly negatively correlated with each other and showed strongly negative and positive correlations with age, respectively, but not with sex. Additionally, there was no significant difference between the FA and the ADC values at different cervical levels. The DTI technique can act as an important supplement to the conventional MRI technique for CSC observation. Moreover, the FA and ADC values can be used as sensitive parameters in the DTI study on the CSC by taking the effects of age into consideration.

  11. Signal-shot echo-planner diffusion-weighted MR imaging at 3T and 1.5T for differentiation of benign vertebral fracture edema and tumor infiltration

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hee Jin; Lee, So Yeon; Rho, Myung Ho; Chung, Eun Chul; Kim, Mi Sung; Kwon, Heon Ju; Youn, In Young [Dept. of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2016-09-15

    To compare the apparent diffusion coefficient (ADC) value using single-shot echo-planar imaging sequences at 3T and 1.5T for differentiation of benign fracture edema and tumor infiltration of the vertebral body. A total of 46 spinal examinations were included in the 1.5T MRI group, and a total of 40 spinal examinations were included in the 3T MRI group. The ADC values of the lesion were measured and calculated. The diagnostic performance of the conventional MR image containing sagittal T2-weighted fat saturated image and each diffusion weighted image (DWI) with an ADC value with different b values were evaluated. The mean ADC value of the benign lesions was higher than that of the malignant lesions on 1.5T and 3T (p < 0.05). The sensitivity of the diagnostic performance was higher with an additional DWI in both 1.5T and 3T, but the sensitivities were similar with the addition of b values of 400 and 1000. The specificities of the diagnostic performances did not show significant differences (p value > 0.05). The diagnostic accuracies were higher when either of the DWIs (b values of 400 and 1000) was added to routine MR image for 1.5T and 3T. Statistical differences between 1.5T and 3T or between b values of 400 and 1000 were not seen. The ADC values of the benign lesions were significantly higher than those of the malignant lesions on 1.5T and 3T. There was no statistically significant difference in the diagnostic performances when either of the DWIs (b values of 400 and 1000) was added to the routine MR image for 1.5T and 3T.

  12. Diffusion tensor imaging and fiber tractography in cervical compressive myelopathy: preliminary results

    International Nuclear Information System (INIS)

    Lee, Joon Woo; Kim, Jae Hyoung; Park, Jong Bin; Lee, Guen Young; Kang, Heung Sik; Park, Kun Woo; Yeom, Jin S.

    2011-01-01

    To assess diffusion tensor imaging (DTI) parameters in cervical compressive myelopathy (CCM) patients compared to normal volunteers, to relate them with myelopathy severity, and to relate tractography patterns with postoperative neurologic improvement. Twenty patients suffering from CCM were prospectively enrolled (M:F = 13:7, mean age, 49.6 years; range 22-67 years) from September 2009 to March 2010. Sensitivity encoding (SENSE) single-shot echo-planar imaging (EPI) was used for the sagittal DTI. Twenty sex- and age-matched normal volunteers underwent the same scanning procedure. Fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values in the spinal cord were compared between the patients and normal volunteers and were related to myelopathy severity based on Japanese Orthopedic Association (JOA) scores. Tractography patterns were related to myelopathy severity and postoperative improvement. There were significant differences between patients and normal volunteers in terms of FA (0.498 ± 0.114 vs. 0.604 ± 0.057; p = 0.001) and ADC (1.442 ± 0.389 vs. 1.169 ± 0.098; p = 0.001). DTI parameters and tractography patterns were not related to myelopathy severity. In ten patients in the neurologically worse group, postoperative neurologic improvement was seen in four of five patients with intact fiber tracts, but only one of five patients with interrupted fiber tracts exhibited neurologic improvement. DTI parameters in CCM patients were significantly different from those in normal volunteers but were not significantly related to myelopathy severity. The patterns of tractography appear to correlate with postoperative neurologic improvement. (orig.)

  13. Value of 3 Tesla diffusion-weighted magnetic resonance imaging for assessing liver fibrosis.

    Science.gov (United States)

    Papalavrentios, Lavrentios; Sinakos, Emmanouil; Chourmouzi, Danai; Hytiroglou, Prodromos; Drevelegas, Konstantinos; Constantinides, Manos; Drevelegas, Antonios; Talwalkar, Jayant; Akriviadis, Evangelos

    2015-01-01

    Limited data are available regarding the role of magnetic resonance imaging (MRI), particularly the new generation 3 Tesla technology, and especially diffusion-weighted imaging (DWI) in predicting liver fibrosis. The aim of our pilot study was to assess the clinical performance of the apparent diffusion coefficient (ADC) of liver parenchyma for the assessment of liver fibrosis in patients with non-alcoholic fatty liver disease (NAFLD). 18 patients with biopsy-proven NAFLD underwent DWI with 3 Tesla MRI. DWI was performed with single-shot echo-planar technique at b values of 0-500 and 0-1000 s/mm 2 . ADC was measured in four locations in the liver and the mean ADC value was used for analysis. Staging of fibrosis was performed according to the METAVIR system. The median age of patients was 52 years (range 23-73). The distribution of patients in different fibrosis stages was: 0 (n=1), 1 (n=7), 2 (n=1), 3 (n=5), 4 (n=4). Fibrosis stage was poorly associated with ADC at b value of 0-500 s/mm 2 (r= -0.30, P=0.27). However it was significantly associated with ADC at b value of 0-1000 s/mm 2 (r= -0.57, P=0.01). For this b value (0-1000 s/mm 2 ) the area under receiver-operating characteristic curve was 0.93 for fibrosis stage ≥3 and the optimal ADC cut-off value was 1.16 ×10 -3 mm 2 /s. 3 Tesla DWI can possibly predict the presence of advanced fibrosis in patients with NAFLD.

  14. Diffusion-weighted MR imaging of pleural fluid: differentiation of transudative vs exudative pleural effusions

    International Nuclear Information System (INIS)

    Baysal, T.; Bulut, T.; Dusak, A.; Dogan, M.; Goekirmak, M.; Kalkan, S.

    2004-01-01

    The aim of this study was to evaluate the ability of diffusion-weighted MRI in differentiating transudative from exudative pleural effusions. Fifty-seven patients with pleural effusion were studied. Diffusion-weighted imaging (DWI) was performed with an echo-planar imaging (EPI) sequence (b values 0, 1000 s/mm 2 ) in 52 patients. The apparent diffusion coefficient (ADC) values were reconstructed from three different regions. Subsequently, thoracentesis was performed and the pleural fluid was analyzed. Laboratory results revealed 20 transudative and 32 exudative effusions. Transudates had a mean ADC value of 3.42±0.76 x 10 -3 mm 2 /s. Exudates had a mean ADC value of 3.18±1.82 x 10 -3 mm 2 /s. The optimum cutoff point for ADC values was 3.38 x 10 -3 mm 2 /s with a sensitivity of 90.6% and specificity of 85%. A significant negative correlation was seen between ADC values and pleural fluid protein, albumin concentrations and lactate dehydrogenase (LDH) measurements (r=-0.69, -0.66, and -0.46, respectively; p<0.01). The positive predictive value, negative predictive value, and diagnostic accuracy of ADC values were determined to be 90.6, 85, and 88.5%, respectively. The application of diffusion gradients to analyze pleural fluid may be an alternative to the thoracentesis. Non-invasive characterization of a pleural effusion by means of DWI with single-shot EPI technique may obviate the need for thoracentesis with its associated patient morbidity. (orig.)

  15. Apparent diffusion coefficient value of gastric cancer by diffusion-weighted imaging: Correlations with the histological differentiation and Lauren classification

    International Nuclear Information System (INIS)

    Liu, Song; Guan, Wenxian; Wang, Hao; Pan, Liang; Zhou, Zhuping; Yu, Haiping; Liu, Tian; Yang, Xiaofeng; He, Jian; Zhou, Zhengyang

    2014-01-01

    Highlights: • Gastric cancers’ ADC values were significantly lower than normal gastric wall. • Gastric adenocarcinomas with different differentiation had different ADC values. • Gastric adenocarcinomas’ ADC values correlated with histologic differentiations. • Gastric cancers’ ADC values correlated with Lauren classifications. • Mean ADC value was better than min ADC value in characterizing gastric cancers. - Abstract: Objective: The purpose of this study was to evaluate the correlations between histological differentiation and Lauren classification of gastric cancer and the apparent diffusion coefficient (ADC) value of diffusion weighted imaging (DWI). Materials and methods: Sixty-nine patients with gastric cancer lesions underwent preoperative magnetic resonance imaging (MRI) (3.0T) and surgical resection. DWI was obtained with a single-shot, echo-planar imaging sequence in the axial plane (b values: 0 and 1000 s/mm 2 ). Mean and minimum ADC values were obtained for each gastric cancer and normal gastric walls by two radiologists, who were blinded to the histological findings. Histological type, degree of differentiation and Lauren classification of each resected specimen were determined by one pathologist. Mean and minimum ADC values of gastric cancers with different histological types, degrees of differentiation and Lauren classifications were compared. Correlations between ADC values and histological differentiation and Lauren classification were analyzed. Results: The mean and minimum ADC values of gastric cancers, as a whole and separately, were significantly lower than those of normal gastric walls (all p values <0.001). There were significant differences in the mean and minimum ADC values among gastric cancers with different histological types, degrees of differentiation and Lauren classifications (p < 0.05). Mean and minimum ADC values correlated significantly (all p < 0.001) with histological differentiation (r = 0.564, 0.578) and Lauren

  16. Functional magnetic resonance imaging of the primary motor cortex

    Indian Academy of Sciences (India)

    Functional magnetic resonance imaging (fMRI) studies have been performed on 20 right handed volunteers at 1.5 Tesla using echo planar imaging (EPI) protocol. Index finger tapping invoked localized activation in the primary motor area. Consistent and highly reproducible activation in the primary motor area was observed ...

  17. Nonenhanced ECG-gated quiescent-interval single-shot MRA (QISS-MRA) of the lower extremities: Comparison with contrast-enhanced MRA

    Energy Technology Data Exchange (ETDEWEB)

    Klasen, J. [Department of Diagnostic and Interventional Radiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Blondin, D., E-mail: blondin@med.uni-duesseldorf.de [Department of Diagnostic and Interventional Radiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Schmitt, P. [Siemens AG, Healthcare Sector, Erlangen (Germany); Bi, X. [Siemens Healthcare, Chicago, IL (United States); Sansone, R. [Department of Cardiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Wittsack, H.-J.; Kroepil, P.; Quentin, M.; Kuhlemann, J.; Miese, F. [Department of Diagnostic and Interventional Radiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Heiss, C.; Kelm, M. [Department of Cardiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Antoch, G.; Lanzman, R.S. [Department of Diagnostic and Interventional Radiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany)

    2012-05-15

    Aim: To evaluate electrocardiogram (ECG)-gated quiescent-interval single-shot magnetic resonance angiography (QISS-MRA) for nonenhanced assessment of peripheral artery occlusive disease (PAOD) using contrast-enhanced MRA (CE-MRA) as the reference standard. Materials and methods: Twenty-seven patients (mean age 66.6 {+-} 10.8 years) with PAOD were included in the study. QISS-MRA and CE-MRA of the lower extremity were performed using a 1.5 T MR scanner. In each patient, subjective image quality and the degree of stenosis were evaluated on a four-point scale for 15 predefined arterial segments. Results: Twenty-five of the 27 patients were considered for analysis. Subjective image quality of QISS-MRA was significantly lower for the distal aorta, pelvic arteries, and femoral arteries as compared to CE-MRA (p < 0.01), while no significant difference was found for other vascular segments. The degree of stenosis was overestimated with QISS-MRA in 23 of 365 (6.3%) segments and underestimated in two of 365 (0.5%) segments. As compared to CE-MRA, QISS-MRA had a high sensitivity (98.6%), specificity (96%) as well as positive and negative predictive value (88.7 and 99.6%, respectively) for the detection of significant stenosis ({>=}50%). Conclusion: ECG-gated QISS-MRA is a promising imaging technique for reliable assessment of PAOD without the use of contrast material.

  18. Nonenhanced ECG-gated quiescent-interval single-shot MRA (QISS-MRA) of the lower extremities: Comparison with contrast-enhanced MRA

    International Nuclear Information System (INIS)

    Klasen, J.; Blondin, D.; Schmitt, P.; Bi, X.; Sansone, R.; Wittsack, H.-J.; Kröpil, P.; Quentin, M.; Kuhlemann, J.; Miese, F.; Heiss, C.; Kelm, M.; Antoch, G.; Lanzman, R.S.

    2012-01-01

    Aim: To evaluate electrocardiogram (ECG)-gated quiescent-interval single-shot magnetic resonance angiography (QISS-MRA) for nonenhanced assessment of peripheral artery occlusive disease (PAOD) using contrast-enhanced MRA (CE-MRA) as the reference standard. Materials and methods: Twenty-seven patients (mean age 66.6 ± 10.8 years) with PAOD were included in the study. QISS-MRA and CE-MRA of the lower extremity were performed using a 1.5 T MR scanner. In each patient, subjective image quality and the degree of stenosis were evaluated on a four-point scale for 15 predefined arterial segments. Results: Twenty-five of the 27 patients were considered for analysis. Subjective image quality of QISS-MRA was significantly lower for the distal aorta, pelvic arteries, and femoral arteries as compared to CE-MRA (p < 0.01), while no significant difference was found for other vascular segments. The degree of stenosis was overestimated with QISS-MRA in 23 of 365 (6.3%) segments and underestimated in two of 365 (0.5%) segments. As compared to CE-MRA, QISS-MRA had a high sensitivity (98.6%), specificity (96%) as well as positive and negative predictive value (88.7 and 99.6%, respectively) for the detection of significant stenosis (≥50%). Conclusion: ECG-gated QISS-MRA is a promising imaging technique for reliable assessment of PAOD without the use of contrast material.

  19. Diffusion-weighted magnetic resonance imaging for pretreatment prediction and monitoring of treatment response of patients with locally advanced breast cancer undergoing neoadjuvant chemotherapy

    International Nuclear Information System (INIS)

    Nilsen, Line; Olsen, Dag Rune; Seierstad, Therese; Fangberget, Anne; Geier, Oliver

    2010-01-01

    Background. For patients with locally advanced breast cancer (LABC) undergoing neoadjuvant chemotherapy (NACT), the European Guidelines for Breast Imaging recommends magnetic resonance imaging (MRI) to be performed before start of NACT, when half of the NACT has been administered and prior to surgery. This is the first study addressing the value of flow-insensitive apparent diffusion coefficients (ADCs) obtained from diffusion-weighted (DW) MRI at the recommended time points for pretreatment prediction and monitoring of treatment response. Materials and methods. Twenty-five LABC patients were included in this prospective study. DW MRI was performed using single-shot spin-echo echo-planar imaging with b-values of 100, 250 and 800 s/mm 2 prior to NACT, after four cycles of NACT and at the conclusion of therapy using a 1.5 T MR scanner. ADC in the breast tumor was calculated from each assessment. The strength of correlation between pretreatment ADC, ADC changes and tumor volume changes were examined using Spearman's rho correlation test. Results. Mean pretreatment ADC was 1.11 ± 0.21 x 10 -3 mm 2 /s. After 4 cycles of NACT, ADC was significantly increased (1.39 ± 0.36 x 10 -3 mm 2 /s; p=0.018). There was no correlation between individual pretreatment breast tumor ADC and MR response measured after four cycles of NACT (p=0.816) or prior to surgery (p=0.620). Conclusion. Pretreatment tumor ADC does not predict treatment response for patients with LABC undergoing NACT. Furthermore, ADC increase observed mid-way in the course of NACT does not correlate with tumor volume changes.

  20. Single shot fringe pattern phase demodulation using Hilbert-Huang transform aided by the principal component analysis.

    Science.gov (United States)

    Trusiak, Maciej; Służewski, Łukasz; Patorski, Krzysztof

    2016-02-22

    Hybrid single shot algorithm for accurate phase demodulation of complex fringe patterns is proposed. It employs empirical mode decomposition based adaptive fringe pattern enhancement (i.e., denoising, background removal and amplitude normalization) and subsequent boosted phase demodulation using 2D Hilbert spiral transform aided by the Principal Component Analysis method for novel, correct and accurate local fringe direction map calculation. Robustness to fringe pattern significant noise, uneven background and amplitude modulation as well as local fringe period and shape variations is corroborated by numerical simulations and experiments. Proposed automatic, adaptive, fast and comprehensive fringe analysis solution compares favorably with other previously reported techniques.

  1. Differentiation of benign and malignant solid pancreatic masses using magnetic resonance elastography with spin-echo echo planar imaging and three-dimensional inversion reconstruction. A prospective study

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Yu; Yu, Bing; Liu, Yanqing; Guo, Qiyong [Shengjing Hospital of China Medical University, Department of Radiology, Shenyang (China); Gao, Feng [Shengjing Hospital of China Medical University, Department of Hepato-Pancreato-Biliary Tumour Surgery, Shenyang (China); Li, Yue [Shengjing Hospital of China Medical University, Department of Pathology, Shenyang (China); Tao, Shengzhen; Glaser, Kevin J.; Ehman, Richard L. [Mayo Clinic, Department of Radiology, Rochester, MN (United States); Liu, Zaiyi [Guangdong Academy of Medical Sciences, Department of Radiology, Guangdong General Hospital, Guangdong (China)

    2018-03-15

    To determine the diagnostic performance of MR elastography (MRE) and compare it with serum CA19-9 in differentiating malignant from benign pancreatic masses, with emphasis on differentiating between pancreatic ductal adenocarcinoma (PDAC) and mass-forming pancreatitis (MFP). We performed a prospective, consecutive, 24-month study in 85 patients with solid pancreatic masses confirmed by histopathologic examinations. The mass stiffness and stiffness ratio (calculated as the ratio of mass stiffness to the parenchymal stiffness) were assessed. The diagnostic accuracy was analysed by calculating the area under the ROC curve (AUROC). The final diagnosis included 54 malignant tumours (43 patients with PDAC) and 31 benign masses (24 patients with MFP). The stiffness ratio showed better diagnostic performance than the mass stiffness and serum CA19-9 for the differentiation between malignant and benign masses (AUC: 0.912 vs. 0.845 vs. 0.702; P = 0.026, P < 0.001) and, specifically, between PDAC and MFP (AUC: 0.955 vs. 0.882 vs. 0.745; P = 0.026, P = 0.003). The sensitivity, specificity, and accuracy of stiffness ratio for the differentiation of PDAC and MFP were all higher than 0.9. MRE presents an effective and quantitative strategy for non-invasive differentiation between PDAC and MFP based on their mechanical properties. (orig.)

  2. Urinary retention in unilateral total knee arthroplasty: comparison between continuous epidural analgesia and single-shot femoral nerve block

    International Nuclear Information System (INIS)

    Khan, A.A.; Khan, R.I.

    2018-01-01

    To compare the frequency of urinary retention and requirement of bladder catheterization in patients undergoing toatal knee arthroplasty while receiving either continuous epidural analgesia or single-shot femoral nerve block. Study Design: Randomized controlled study. Place and Duration of Study:Operating Rooms of Aga Khan University Hospital, Karachi, from January 2014 to January 2015. Methodology:Patients were randomized in two groups of 30 each, i.e. epidural group (group E) or femoral nerve block group (group F). Baseline parameters were recorded. Postoperatively, patients were followed for upto 24 hours to collect the data regarding urinary retention. Final outcome was taken at 24 hours postoperatively. Data was analyzed to compare the frequency of urinary retention between the two groups. Results:The average age of the patients was 59.58 +-5.85 years. There were 28 (46.7%) male and 32 (53.3%) female patients. Frequency of urinary retention was significantly high in Group E than Group F (46.7% vs. 6.7%; p=0.0005). Conclusion: Single-shot femoral nerve block offers a more favorable profile in terms of postoperative urinary retention when compared to continuous epidural analgesia. (author)

  3. Optimization of laser energy deposition for single-shot high aspect-ratio microstructuring of thick BK7 glass

    Energy Technology Data Exchange (ETDEWEB)

    Garzillo, Valerio; Grigutis, Robertas [Dipartimento di Scienza e Alta Tecnologia, University of Insubria, Via Valleggio 11, I-22100 Como (Italy); Jukna, Vytautas [Centre de Physique Theorique, CNRS, Ecole Polytechnique, Université Paris-Saclay, F-91128 Palaiseau (France); LOA, ENSTA-ParisTech, CNRS, Ecole Polytechnique, Université Paris Saclay, F-91762 Palaiseau (France); Couairon, Arnaud [Centre de Physique Theorique, CNRS, Ecole Polytechnique, Université Paris-Saclay, F-91128 Palaiseau (France); Di Trapani, Paolo [Dipartimento di Scienza e Alta Tecnologia, University of Insubria and CNISM UdR Como, Via Valleggio 11, I-22100 Como (Italy); Jedrkiewicz, Ottavia, E-mail: ottavia.jedrkiewicz@ifn.cnr.it [Istituto di Fotonica e Nanotecnologie, CNR and CNISM UdR Como, Via Valleggio 11, I-22100 Como (Italy)

    2016-07-07

    We investigate the generation of high aspect ratio microstructures across 0.7 mm thick glass by means of single shot Bessel beam laser direct writing. We study the effect on the photoinscription of the cone angle, as well as of the energy and duration of the ultrashort laser pulse. The aim of the study is to optimize the parameters for the writing of a regular microstructure due to index modification along the whole sample thickness. By using a spectrally resolved single pulse transmission diagnostics at the output surface of the glass, we correlate the single shot material modification with observations of the absorption in different portions of the retrieved spectra, and with the absence or presence of spectral modulation. Numerical simulations of the evolution of the Bessel pulse intensity and of the energy deposition inside the sample help us interpret the experimental results that suggest to use picosecond pulses for an efficient and more regular energy deposition. Picosecond pulses take advantage of nonlinear plasma absorption and avoid temporal dynamics effects which can compromise the stationarity of the Bessel beam propagation.

  4. Inter-individual, inter-vendor comparison of diffusion-weighted MR imaging of upper abdominal organs at 3.0 tesla with an emphasis on the value of normalization with the spleen

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ji Soo; Hwang, Seung Bae; Chung, Gyung Ho; Jin, Gong Yong [Dept. of Radiology, Chonbuk National University Medical School and Hospital, Jeonju (Korea, Republic of)

    2016-04-15

    To compare the apparent diffusion coefficient (ADC) values of upper abdominal organs with 2 different 3.0 tesla MR systems and to investigate the usefulness of normalization using the spleen. Forty-one patients were enrolled in this prospective study, of which, 35 patients (M:F, 27:8; mean age ± standard deviation, 62.3 ± 12.3 years) were finally analyzed. In addition to the routine liver MR protocol, single-shot spin-echo echo-planar diffusion-weighted imaging using b values of 0, 50, 400, and 800 s/mm{sup 2} in 2 different MR systems was performed. ADC values of the liver, spleen, pancreas, kidney and liver lesion (if present) were measured and analyzed. ADC values of the spleen were used for normalization. The Pearson correlation, Spearman correlation, paired sample t test, Wilcoxon signed rank test and Bland-Altman method were used for statistical analysis. For all anatomical regions and liver lesions, both non-normalized and normalized ADC values from 2 different MR systems showed significant correlations (r = 0.5196-0.8488). Non-normalized ADC values of both MR systems differed significantly in all anatomical regions and liver lesions (p < 0.001). However, the normalized ADC of all anatomical regions and liver lesions did not differ significantly (p = 0.065-0.661), with significantly lower coefficient of variance than that of non-normalized ADC (p < 0.009). Normalization of the abdominal ADC values using the spleen as a reference organ reduces differences between different MR systems, and could facilitate consistent use of ADC as an imaging biomarker for multi-center or longitudinal studies.

  5. Single-shot spectro-temporal characterization of XUV pulses from a seeded free-electron laser

    Science.gov (United States)

    de Ninno, Giovanni; Gauthier, David; Mahieu, Benoît; Ribič, Primož Rebernik; Allaria, Enrico; Cinquegrana, Paolo; Danailov, Miltcho Bojanov; Demidovich, Alexander; Ferrari, Eugenio; Giannessi, Luca; Penco, Giuseppe; Sigalotti, Paolo; Stupar, Matija

    2015-08-01

    Intense ultrashort X-ray pulses produced by modern free-electron lasers (FELs) allow one to probe biological systems, inorganic materials and molecular reaction dynamics with nanoscale spatial and femtoscale temporal resolution. These experiments require the knowledge, and possibly the control, of the spectro-temporal content of individual pulses. FELs relying on seeding have the potential to produce spatially and temporally fully coherent pulses. Here we propose and implement an interferometric method, which allows us to carry out the first complete single-shot spectro-temporal characterization of the pulses, generated by an FEL in the extreme ultraviolet spectral range. Moreover, we provide the first direct evidence of the temporal coherence of a seeded FEL working in the extreme ultraviolet spectral range and show the way to control the light generation process to produce Fourier-limited pulses. Experiments are carried out at the FERMI FEL in Trieste.

  6. Single-shot mega-electronvolt ultrafast electron diffraction for structure dynamic studies of warm dense matter

    Energy Technology Data Exchange (ETDEWEB)

    Mo, M. Z., E-mail: mmo09@slac.stanford.edu; Shen, X.; Chen, Z.; Li, R. K.; Dunning, M.; Zheng, Q.; Weathersby, S. P.; Reid, A. H.; Coffee, R.; Makasyuk, I.; Edstrom, S.; McCormick, D.; Jobe, K.; Hast, C.; Glenzer, S. H.; Wang, X. [SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025 (United States); Sokolowski-Tinten, K. [Faculty of Physics and Centre for Nanointegration Duisburg-Essen, University of Duisburg-Essen, Lotharstrasse 1, D-47048 Duisburg (Germany)

    2016-11-15

    We have developed a single-shot mega-electronvolt ultrafast-electron-diffraction system to measure the structural dynamics of warm dense matter. The electron probe in this system is featured by a kinetic energy of 3.2 MeV and a total charge of 20 fC, with the FWHM pulse duration and spot size at sample of 350 fs and 120 μm respectively. We demonstrate its unique capability by visualizing the atomic structural changes of warm dense gold formed from a laser-excited 35-nm freestanding single-crystal gold foil. The temporal evolution of the Bragg peak intensity and of the liquid signal during solid-liquid phase transition are quantitatively determined. This experimental capability opens up an exciting opportunity to unravel the atomic dynamics of structural phase transitions in warm dense matter regime.

  7. Value of selective MIP reconstructions of respiratory triggered 3D-TSE-MR cholangiography on a workstation versus standard MIP reconstructions and single-shot MRCP

    International Nuclear Information System (INIS)

    Schaible, R.; Textor, J.; Kreft, B.; Schild, H.; Neubrand, M.

    2001-01-01

    Comparison of anatomical visualisation and diagnostic value of selective MIP reconstructions of respiratory triggered 3D-TSE-MRCP versus standard MIP reconstructions and single-shot MRCP. Material and Methods: 50 patients with pancreaticobiliary disease were examined at 1.5 Tesla (ACS NT II, Philips Medical Systems) using a breath-hold single-shot (SS) and a respiratory triggered 3D-TSE-MRCP technique in 12 standard MIP projections. Additional selective MIP reconstructions with different slice thickness (2, 4, 10 cm) and projections were performed on a workstation. Visualization of the pancreaticobiliary system and the diagnostic value of the examinations were analysed. Results: Single-shot and 3D-TSE in standard projections showed comparable anatomical visualisation. On selective MIP reconstructions the biliary system (SS p [de

  8. Single-shot antithymocyte globulin (ATG) induction for pancreas/kidney transplantation: ATG-Fresenius versus Thymoglobulin.

    Science.gov (United States)

    Schulz, T; Papapostolou, G; Schenker, P; Kapischke, M

    2005-03-01

    Single-shot antithymocyte globulin (ATG) prior to reperfusion followed by tacrolimus (TAC), mycophenolate mofetil (MMF), and prednisolone (PRD) is an established induction therapy in simultaneous pancreas kidney transplant (SPK) recipients. We retrospectively analyzed 6-month data from 105 patients who received their first SPK. From January 1996 to December 2000, ATG-Fresenius was used. Since January 2001, Thymoglobulin has been administered. In the first group, 58 patients were treated with ATG-Fresenius (4-6 mg/kg body weight). In the second group, 47 patients received Thymoglobulin (1.5-2.5 mg/kg body weight). HLA-mismatch was comparable. After an observation period of 6 months, patients, kidney, and pancreas graft survival is 98.3%, 96.6%, and 93.1% in group I and 97.9%, 97.9%, and 85.1% in group II, respectively. In each group, one death with functioning graft (DWFG) was observed. Twenty (34.5%) acute rejection episodes (AR) were observed (18 patients) in group I. They were treated with steroids (n = 16) or steroids/OKT3 (n = 4). One kidney graft failure was observed due to rejection and one due to DWFG. Four pancreas grafts were lost (thrombosis, n = 2; AR, n = 1; DWFG, n = 1). In group II, 15 AR (31.9%) were seen in 12 patients and were treated with steroids (n = 12), steroids/ATG (n = 1), or steroids/OKT3 (n = 2). Seven pancreas (thrombosis, n = 5; rejection, n = 1; DWFG, n = 1) and one kidney (DWFG, n = 1) graft losses occurred. These data clearly establish that single-shot ATG prior to reperfusion, followed by TAC, MMF, and PRD results in a low incidence of AR (34.5% in group I and 31.9% in group II) after SPK. Only 6.9% (group I) and 6.4% (group II) of the patients received antibodies for rejection treatment.

  9. Characterization of temporal coherence of hard X-ray free-electron laser pulses with single-shot interferograms

    Directory of Open Access Journals (Sweden)

    Taito Osaka

    2017-11-01

    Full Text Available Temporal coherence is one of the most fundamental characteristics of light, connecting to spectral information through the Fourier transform relationship between time and frequency. Interferometers with a variable path-length difference (PLD between the two branches have widely been employed to characterize temporal coherence properties for broad spectral regimes. Hard X-ray interferometers reported previously, however, have strict limitations in their operational photon energies, due to the specific optical layouts utilized to satisfy the stringent requirement for extreme stability of the PLD at sub-ångström scales. The work presented here characterizes the temporal coherence of hard X-ray free-electron laser (XFEL pulses by capturing single-shot interferograms. Since the stability requirement is drastically relieved with this approach, it was possible to build a versatile hard X-ray interferometer composed of six separate optical elements to cover a wide photon energy range from 6.5 to 11.5 keV while providing a large variable delay time of up to 47 ps at 10 keV. A high visibility of up to 0.55 was observed at a photon energy of 10 keV. The visibility measurement as a function of time delay reveals a mean coherence time of 5.9 ± 0.7 fs, which agrees with that expected from the single-shot spectral information. This is the first result of characterizing the temporal coherence of XFEL pulses in the hard X-ray regime and is an important milestone towards ultra-high energy resolutions at micro-electronvolt levels in time-domain X-ray spectroscopy, which will open up new opportunities for revealing dynamic properties in diverse systems on timescales from femtoseconds to nanoseconds, associated with fluctuations from ångström to nanometre spatial scales.

  10. Diffusion weighted MR imaging of pancreatic islet cell tumors

    International Nuclear Information System (INIS)

    Bakir, Baris; Salmaslioglu, Artur; Poyanli, Arzu; Rozanes, Izzet; Acunas, Bulent

    2010-01-01

    Purpose: The aim of our study is to demonstrate the feasibility of body diffusion weighted (DW) MR imaging in the evaluation of pancreatic islet cell tumors (ICTs) and to define apparent diffusion coefficient (ADC) values for these tumors. Materials and methods: 12 normal volunteers and 12 patients with histopathologically proven pancreatic ICT by surgery were included in the study. DW MR images were obtained by a body-phased array coil using a multisection single-shot echo planar sequence on the axial plane without breath holding. In addition, the routine abdominal imaging protocol for pancreas was applied in the patient group. We measured the ADC value within the normal pancreas in control group, pancreatic ICT, and surrounding pancreas parenchyma. Mann-Whitney U-test has been used to compare ADC values between tumoral tissues and normal pancreatic tissues of the volunteers. Wilcoxon Signed Ranks Test was preferred to compare ADC values between tumoral tissues and surrounding pancreatic parenchyma of the patients. Results: In 11 patients out of 12, conventional MR sequences were able to demonstrate ICTs successfully. In 1 patient an indistinct suspicious lesion was noted at the pancreatic tail. DW sequence was able to demonstrate the lesions in all of the 12 patients. On the DW images, all ICTs demonstrated high signal intensity relative to the surrounding pancreatic parenchyma. The mean and standard deviations of the ADC values (x10 -3 mm 2 /s) were as follows: ICT (n = 12), 1.51 ± 0.35 (0.91-2.11), surrounding parenchyma (n = 11) 0.76 ± 0.15 (0.51-1.01) and normal pancreas in normal volunteers (n = 12), 0.80 ± 0.06 (0.72-0.90). ADC values of the ICT were significantly higher compared with those of surrounding parenchyma (p < 0.01) and normal pancreas (p < 0.001). Conclusion: DW MR imaging does not appear to provide significant contribution to routine MR imaging protocol in the evaluation of pancreatic islet cell tumors. But it can be added to MR imaging

  11. Non-contrast-enhanced MR angiography in critical limb ischemia: performance of quiescent-interval single-shot (QISS) and TSE-based subtraction techniques

    Energy Technology Data Exchange (ETDEWEB)

    Altaha, Mustafa A. [University Health Network, Department of Medical Imaging, Peter Munk Cardiac Centre, Toronto, Ontario (Canada); Jaskolka, Jeffrey D.; Tan, Kongteng; Menezes, Ravi J. [University Health Network, Department of Medical Imaging, Peter Munk Cardiac Centre, Toronto, Ontario (Canada); University of Toronto, Department of Medical Imaging, Toronto, Ontario (Canada); Rick, Manuela; Schmitt, Peter [Siemens Healthcare, Erlangen (Germany); Wintersperger, Bernd J. [University Health Network, Department of Medical Imaging, Peter Munk Cardiac Centre, Toronto, Ontario (Canada); University of Toronto, Department of Medical Imaging, Toronto, Ontario (Canada); Toronto General Hospital, Department of Medical Imaging, Toronto, Ontario (Canada)

    2017-03-15

    The aim of this study was to evaluate diagnostic performance of non-contrast-enhanced 2D quiescent-interval single-shot (QISS) and 3D turbo spin-echo (TSE)-based subtraction magnetic resonance angiography (MRA) in the assessment of peripheral arteries in patients with critical limb ischemia (CLI). Nineteen consecutive patients (74 % male, 72.8 ± 9.9 years) with CLI underwent 2D QISS and 3D TSE-based subtraction MRA at 1.5 T. Axial-overlapping QISS MRA (3 mm/2 mm; 1 x 1 mm{sup 2}) covered from the toes to the aortic bifurcation while coronal 3D TSE-based subtraction MRA (1.3 x 1.2 x 1.3 mm{sup 3}) was restricted to the calf only. MRA data sets (two readers) were evaluated for stenosis (≥50 %) and image quality. Results were compared with digital subtraction angiography (DSA). Two hundred and sixty-seven (267) segments were available for MRA-DSA comparison, with a prevalence of stenosis ≥50 % of 41.9 %. QISS MRA was rated as good to excellent in 79.5-96.0 % of segments without any nondiagnostic segments; 89.8-96.1 % of segments in 3D TSE-based subtraction MRA were rated as nondiagnostic or poor. QISS MRA sensitivities and specificities (segmental) were 92 % and 95 %, respectively, for reader one and 81-97 % for reader two. Due to poor image quality of 3D TSE-based subtraction MRA, diagnostic performance measures were not calculated. QISS MRA demonstrates excellent diagnostic performance and higher robustness than 3D TSE-based subtraction MRA in the challenging patient population with CLI. (orig.)

  12. Non-contrast-enhanced MR angiography in critical limb ischemia: performance of quiescent-interval single-shot (QISS) and TSE-based subtraction techniques

    International Nuclear Information System (INIS)

    Altaha, Mustafa A.; Jaskolka, Jeffrey D.; Tan, Kongteng; Menezes, Ravi J.; Rick, Manuela; Schmitt, Peter; Wintersperger, Bernd J.

    2017-01-01

    The aim of this study was to evaluate diagnostic performance of non-contrast-enhanced 2D quiescent-interval single-shot (QISS) and 3D turbo spin-echo (TSE)-based subtraction magnetic resonance angiography (MRA) in the assessment of peripheral arteries in patients with critical limb ischemia (CLI). Nineteen consecutive patients (74 % male, 72.8 ± 9.9 years) with CLI underwent 2D QISS and 3D TSE-based subtraction MRA at 1.5 T. Axial-overlapping QISS MRA (3 mm/2 mm; 1 x 1 mm 2 ) covered from the toes to the aortic bifurcation while coronal 3D TSE-based subtraction MRA (1.3 x 1.2 x 1.3 mm 3 ) was restricted to the calf only. MRA data sets (two readers) were evaluated for stenosis (≥50 %) and image quality. Results were compared with digital subtraction angiography (DSA). Two hundred and sixty-seven (267) segments were available for MRA-DSA comparison, with a prevalence of stenosis ≥50 % of 41.9 %. QISS MRA was rated as good to excellent in 79.5-96.0 % of segments without any nondiagnostic segments; 89.8-96.1 % of segments in 3D TSE-based subtraction MRA were rated as nondiagnostic or poor. QISS MRA sensitivities and specificities (segmental) were 92 % and 95 %, respectively, for reader one and 81-97 % for reader two. Due to poor image quality of 3D TSE-based subtraction MRA, diagnostic performance measures were not calculated. QISS MRA demonstrates excellent diagnostic performance and higher robustness than 3D TSE-based subtraction MRA in the challenging patient population with CLI. (orig.)

  13. ECG-gated quiescent-interval single-shot MR angiography of the lower extremities: Initial experience at 3 T

    International Nuclear Information System (INIS)

    Knobloch, G.; Gielen, M.; Lauff, M.-T.; Romano, V.C.; Schmitt, P.; Rick, M.; Kröncke, T.J.; Huppertz, A.; Hamm, B.; Wagner, M.

    2014-01-01

    Aim: To evaluate the feasibility of unenhanced electrocardiography (ECG)-gated quiescent-interval single-shot magnetic resonance angiography (QISS-MRA) of the lower extremities at 3 T. Materials and methods: Twenty-five patients with known or suspected peripheral arterial disease underwent ECG-gated QISS-MRA and contrast-enhanced MRA (CE-MRA) at 3 T. Two independent readers performed a per-segment evaluation of the MRA datasets. Image quality was rated on a four-point scale (1 = excellent to 4 = non-diagnostic; presented as medians with interquartile range). Diagnostic performance of QISS-MRA was evaluated using CE-MRA as the reference standard. Results: QISS-MRA and CE-MRA of all patients were considered for analysis, resulting in 807 evaluated vessel segments for each MRA technique. Readers 1 and 2 rated image quality of QISS-MRA as diagnostic in 97.3% and 97% of the vessel segments, respectively. CE-MRA was rated diagnostic in all vessel segments. Image quality of the proximal vessel segments, including the infrarenal aorta, iliac arteries, and common femoral artery, was significantly lower on QISS-MRA compared to CE-MRA [image quality score across readers: 2 (1,3) versus 1 (1,1) p < 0.001]. In the more distal vessel segments, image quality of QISS-MRA was excellent and showed no significant difference compared to CE-MRA [image quality score across readers: 1 (1,1) versus 1 (1,1) p = 0.036]. Diagnostic performance of QISS-MRA was as follows (across readers): sensitivity: 87.5% (95% CI: 80.2–92.4%); specificity: 96.1% (95% CI: 93.6–97.6%); diagnostic accuracy: 94.9% (95% CI: 92.6–96.5%). Conclusions: QISS-MRA of the lower extremities is feasible at 3 T and provides high image quality, especially in the distal vessel segments

  14. Symptomatic hepatic cyst in a child: treatment with single-shot injection of tetracycline hydrochloride

    International Nuclear Information System (INIS)

    Fabrizzi, Giancarlo; Lanza, Cecilia; Bolli, Valeria; Pieroni, Giovanni

    2009-01-01

    The prevalence of hepatic cysts is 0.1% to 0.5% based on autopsy studies, and 2.5% based on US examinations. Percutaneous therapies are a new alternative to surgery. They include simple percutaneous aspiration, catheter drainage alone, and catheter drainage with sclerotherapy. We present an 11-year-old boy admitted to hospital because of abdominal pain. A diagnosis of simple hepatic cyst was made, which was treated with aspiration and tetracycline hydrochloride solution (5%) injection into the cystic cavity. Complete regression was seen on US and MRI examination at 3 months, with total collapse and deflation of the cyst. The cyst regressed totally, leaving a hyperechoic linear scar on US examination at 1 year. On the basis of the clinical and imaging results obtained, percutaneous sclerotherapy of hepatic cysts can be recommended as the treatment of choice and as a valid alternative to laparoscopy in children. (orig.)

  15. Tabletop single-shot extreme ultraviolet Fourier transform holography of an extended object.

    Science.gov (United States)

    Malm, Erik B; Monserud, Nils C; Brown, Christopher G; Wachulak, Przemyslaw W; Xu, Huiwen; Balakrishnan, Ganesh; Chao, Weilun; Anderson, Erik; Marconi, Mario C

    2013-04-22

    We demonstrate single and multi-shot Fourier transform holography with the use of a tabletop extreme ultraviolet laser. The reference wave was produced by a Fresnel zone plate with a central opening that allowed the incident beam to illuminate the sample directly. The high reference wave intensity allows for larger objects to be imaged compared to mask-based lensless Fourier transform holography techniques. We obtain a spatial resolution of 169 nm from a single laser pulse and a resolution of 128 nm from an accumulation of 20 laser pulses for an object ~11x11μm(2) in size. This experiment utilized a tabletop extreme ultraviolet laser that produces a highly coherent ~1.2 ns laser pulse at 46.9 nm wavelength.

  16. Ankle Block vs Single-Shot Popliteal Fossa Block as Primary Anesthesia for Forefoot Operative Procedures: Prospective, Randomized Comparison.

    Science.gov (United States)

    Schipper, Oliver N; Hunt, Kenneth J; Anderson, Robert B; Davis, W Hodges; Jones, Carroll P; Cohen, Bruce E

    2017-11-01

    Postoperative pain is often difficult to control with oral medications, requiring large doses of opioid analgesia. Regional anesthesia may be used for primary anesthesia, reducing the need for general anesthetic and postoperative pain medication requirements in the immediate postoperative period. The purpose of this study was to compare the analgesic effects of an ankle block (AB) to a single-shot popliteal fossa block (PFB) for patients undergoing orthopedic forefoot procedures. All patients having elective outpatient orthopedic forefoot procedures were invited to participate in the study. Patients were prospectively randomized to receive either an ultrasound-guided AB or PFB by a board-certified anesthesiologist prior to their procedure. Intraoperative conversion to general anesthesia and postanesthesia care unit (PACU) opioid requirements were recorded. Postoperative pain was assessed using the visual analog scale (VAS) at regular time intervals until 8 am on postoperative day (POD) 2. Patients rated the effectiveness of the block on a 1 to 5 scale, with 5 being very effective. A total of 167 patients participated in the study with 88 patients (53%) receiving an AB and 79 (47%) receiving a single-shot PFB. There was no significant difference in the rate of conversion to general anesthesia between the 2 groups (13.6% [12/88] AB vs 12.7% [10/79] PFB). PACU morphine requirements and doses were significantly reduced in the PFB group ( P = .004) when compared to the AB group. The VAS was also significantly lower for the PFB patients at 10 pm on POD 0 (4.6 vs 1.6, P block site pain and/or erythema (AB 6.9% [6/88] vs PFB 5.1% [4/79], P = .44). The analgesic effect of the PFB lasted significantly longer when compared to the ankle block (AB 14.5 hours vs PFB 20.9 hours, P block between the 2 groups, with both blocks being highly effective (AB 4.79/5 vs PFB 4.82/5, P = .68). Regional anesthesia was a safe and reliable adjunct to perioperative pain management and highly

  17. Astronomy in Denver: Probing Interstellar Circular Polarization with Polvis, a Full Stokes Single Shot Polarimeter

    Science.gov (United States)

    Wolfe, Tristan; Stencel, Robert E.

    2018-06-01

    Measurements of optical circular polarization (Stokes V) introduced by dust grains in the ISM are important for two main reasons. First of all, the polarization itself contains information about the metallic versus dielectric composition of the dust grains themselves (H. C. van de Hulst 1957, textbook). Additionally, circular polarization can help constrain the interstellar component of the polarization of any source that may have intrinsic polarization, which needs to be calibrated for astrophysical study. Though interstellar circular polarization has been observed (P. G. Martin 1972, MNRAS 159), most broadband measurements of ISM polarization include linear polarization only (Stokes Q and U), due to the relatively low circular polarization signal and the added instrumentation complexity of including V-measurement capability. Prior circular polarization measurements have also received very little follow-up in the past several decades, even as polarimeters have become more accurate due to advances in technology. The University of Denver is pursuing these studies with POLVIS, a prototype polarimeter that utilizes a stress-engineered optic ("SEO", A. K. Spilman and T. G. Brown 2007, Applied Optics IP 46) to produce polarization-dependent PSFs (A. M. Beckley and T. G. Brown 2010, Proc SPIE 7570). These PSFs are analyzed to provide simultaneous Stokes I, Q, U, and V measurements, in a single beam and single image, along the line-of-sight to point source-like objects. Polvis is the first polarimeter to apply these optics and measurement techniques for astronomical observations. We present the first results of this instrument in B, V, and R wavebands, providing a fresh look at full Stokes interstellar polarization. Importantly, this set of efforts will constrain the ISM contribution to the polarization with respect to intrinsic stellar components. The authors are grateful to the estate of William Herschel Womble for the support of astronomy at the University of Denver

  18. Silicon-Vacancy Spin Qubit in Diamond: A Quantum Memory Exceeding 10 ms with Single-Shot State Readout

    Science.gov (United States)

    Sukachev, D. D.; Sipahigil, A.; Nguyen, C. T.; Bhaskar, M. K.; Evans, R. E.; Jelezko, F.; Lukin, M. D.

    2017-12-01

    The negatively charged silicon-vacancy (SiV- ) color center in diamond has recently emerged as a promising system for quantum photonics. Its symmetry-protected optical transitions enable the creation of indistinguishable emitter arrays and deterministic coupling to nanophotonic devices. Despite this, the longest coherence time associated with its electronic spin achieved to date (˜250 ns ) has been limited by coupling to acoustic phonons. We demonstrate coherent control and suppression of phonon-induced dephasing of the SiV- electronic spin coherence by 5 orders of magnitude by operating at temperatures below 500 mK. By aligning the magnetic field along the SiV- symmetry axis, we demonstrate spin-conserving optical transitions and single-shot readout of the SiV- spin with 89% fidelity. Coherent control of the SiV- spin with microwave fields is used to demonstrate a spin coherence time T2 of 13 ms and a spin relaxation time T1 exceeding 1 s at 100 mK. These results establish the SiV- as a promising solid-state candidate for the realization of quantum networks.

  19. Flexible Low-power SiGe HBT Amplifier Circuits for Fast Single-shot Spin Readout

    Science.gov (United States)

    England, Troy; Lilly, Michael; Curry, Matthew; Carr, Stephen; Carroll, Malcolm

    Fast, low-power quantum state readout is one of many challenges facing quantum information processing. Single electron transistors (SETs) are potentially fast, sensitive detectors for performing spin readout of electrons bound to Si:P donors. From a circuit perspective, however, their output impedance and nonlinear conductance are ill suited to drive the parasitic capacitance of coaxial conductors used in cryogenic environments, necessitating a cryogenic amplification stage. We will introduce two new amplifier topologies that provide excellent gain versus power tradeoffs using silicon-germanium (SiGe) heterojunction bipolar transistors (HBTs). The AC HBT allows in-situ adjustment of power dissipation during an experiment and can provide gain in the millikelvin temperature regime while dissipating less than 500 nW. The AC Current Amplifier maximizes gain at nearly 800 A/A. We will also show results of using these amplifiers with SETs at 4 K. This work was performed, in part, at the Center for Integrated Nanotechnologies, a U.S. DOE Office of Basic Energy Sciences user facility. Sandia National Laboratories is a multi-program laboratory operated by Sandia Corporation, a Lockheed-Martin Company, for the U. S. Department of Energy under Contract No. DE-AC04-94AL85000. Flexible Low-power SiGe HBT Amplifier Circuits for Fast Single-shot Spin Readout.

  20. Single-shot quantum nondemolition measurement of a quantum-dot electron spin using cavity exciton-polaritons

    Science.gov (United States)

    Puri, Shruti; McMahon, Peter L.; Yamamoto, Yoshihisa

    2014-10-01

    We propose a scheme to perform single-shot quantum nondemolition (QND) readout of the spin of an electron trapped in a semiconductor quantum dot (QD). Our proposal relies on the interaction of the QD electron spin with optically excited, quantum well (QW) microcavity exciton-polaritons. The spin-dependent Coulomb exchange interaction between the QD electron and cavity polaritons causes the phase and intensity response of left circularly polarized light to be different than that of right circularly polarized light, in such a way that the QD electron's spin can be inferred from the response to a linearly polarized probe reflected or transmitted from the cavity. We show that with careful device design it is possible to essentially eliminate spin-flip Raman transitions. Thus a QND measurement of the QD electron spin can be performed within a few tens of nanoseconds with fidelity ˜99.95%. This improves upon current optical QD spin readout techniques across multiple metrics, including speed and scalability.

  1. Cavity Exciton-Polariton mediated, Single-Shot Quantum Non-Demolition measurement of a Quantum Dot Electron Spin

    Science.gov (United States)

    Puri, Shruti; McMahon, Peter; Yamamoto, Yoshihisa

    2014-03-01

    The quantum non-demolition (QND) measurement of a single electron spin is of great importance in measurement-based quantum computing schemes. The current single-shot readout demonstrations exhibit substantial spin-flip backaction. We propose a QND readout scheme for quantum dot (QD) electron spins in Faraday geometry, which differs from previous proposals and implementations in that it relies on a novel physical mechanism: the spin-dependent Coulomb exchange interaction between a QD spin and optically-excited quantum well (QW) microcavity exciton-polaritons. The Coulomb exchange interaction causes a spin-dependent shift in the resonance energy of the polarized polaritons, thus causing the phase and intensity response of left circularly polarized light to be different to that of the right circularly polarized light. As a result the QD electron's spin can be inferred from the response to a linearly polarized probe. We show that by a careful design of the system, any spin-flip backaction can be eliminated and a QND measurement of the QD electron spin can be performed within a few 10's of nanoseconds with fidelity 99:95%. This improves upon current optical QD spin readout techniques across multiple metrics, including fidelity, speed and scalability. National Institute of Informatics, 2-1-2 Hitotsubashi, Chiyoda-ku, Tokyo 101-8430, Japan.

  2. Real-Time, Single-Shot Temporal Measurements of Short Electron Bunches, Terahertz CSR and FEL Radiation

    CERN Document Server

    Berden, G; Van der Meer, A F G

    2005-01-01

    Electro-optic detection of the Coulomb field of electron bunches is a promising technique for single-shot measurements of the bunch length and shape in the sub-picosecond time domain. This technique has been applied to the measurement of 50 MeV electron bunches in the FELIX free electron laser, showing the longitudinal profile of single bunches of around 650 fs FWHM [Phys. Rev. Lett. 93, 114802 (2004)]. The method is non-destructive and real-time, and therefore ideal for online monitoring of the longitudinal shape of single electron bunches. At FELIX we have used it for real-time optimization of sub-picosecond electron bunches. Electro-optic detection has also been used to measure the electric field profiles of far-infrared (or terahertz) optical pulses generated by the relativistic electrons. We have characterised the far-infrared output of the free electron laser, and more recently, we have measured the temporal profile of terahertz optical pulses generated at one of the bending magnets.

  3. Single-shot T1 mapping of the corpus callosum: A rapid characterization of fiber bundle anatomy

    Directory of Open Access Journals (Sweden)

    Sabine eHofer

    2015-05-01

    Full Text Available Using diffusion-tensor MRI and fiber tractography the topographic organization of the corpus callosum (CC has been described to comprise 5 segments with fibers projecting into prefrontal (I, premotor and supplementary motor (II, primary motor (III, and primary sensory areas (IV, as well as into parietal, temporal, and occipital cortical areas (V. In order to more rapidly characterize the underlying anatomy of these segments, this study used a novel single-shot T1 mapping method to quantitatively determine T1 relaxation times in the human CC. A region-of-interest analysis revealed a tendency for the lowest T1 relaxation times in the genu and the highest T1 relaxation times in the somatomotor region of the CC. This observation separates regions dominated by myelinated fibers with large diameters (somatomotor area from densely packed smaller axonal bundles (genu with less myelin. The results indicate that characteristic T1 relaxation times in callosal profiles provide an additional means to monitor differences in fiber anatomy, fiber density, and gray matter in respective neocortical areas. In conclusion, rapid T1 mapping allows for a characterization of the axonal architecture in an individual CC in less than 10 s. The approach emerges as a valuable means for studying neocortical brain anatomy with possible implications for the diagnosis of neurodegenerative processes.

  4. Imaging and assessment of diffusion coefficients by magnetic resonance

    International Nuclear Information System (INIS)

    Tintera, J.; Dezortova, M.; Hajek, M.; Fitzek, C.

    1999-01-01

    The problem of assessment of molecular diffusion by magnetic resonance is highlighted and some typical applications of diffusion imaging in the diagnosis, e.g., of cerebral ischemia, changes in patients with phenylketonuria or multiple sclerosis are discussed. The images were obtained by using diffusion weighted spin echo Echo-Planar Imaging sequence with subsequent correction of the geometrical distortion of the images and calculation of the Apparent Diffusion Coefficient map

  5. Value of MR cisternography using three-dimensional half-fourier single-shot fast spin-echo sequences in the diagnosis of diseases related to cranial nerves VII and VIII

    Energy Technology Data Exchange (ETDEWEB)

    Yamakami, Norio [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine

    1999-05-01

    The purpose of this study was to evaluate the value of MR cisternography using three-dimensional half-Fourier single-shot fast spin-echo sequences in the diagnosis of diseasea related to cranial nerves VII and VIII. With a 0.5-T imager, the most appropriate setting of echo time and section thickness was first assessed in five volunteers. This resulted in echo time of 250 msec and section thickness of 2 mm as the most effective parameters. Second, using echo time of 120 msec and section thickness of 1.5 mm that were available from the beginning of this study, the demonstration of four nerves within the audistory canal was assessed in seven volunteers. In all of the volunteers, the facial, cochlear, and vestibular nerves were determined with demonstration of each of superior and inferior vestibular nerves in four of them. Next, MR cisternography using the same echo time and section thickness was applied in 368 patients with suspicion of acoustic neurinoma and 14 with hemifacial spasm. In 28 of the 368 patients, MR cisternograms depicted an acoustic neurinoma that was confirmed on postcontrast T1-weighted images. Meanwhile, in five of the 14 patients with hemifacial spasm, MR cisternograms revealed a vessel compressing the root exit zone of the affected facial nerve. It is concluded that MR cisternography using three-dimensional half-Fourier single-shot fast spin-echo sequences can be a useful means for demonstrating nerves within the auditory nerve as well as for the screening of acoustic neurionoma. (author)

  6. Value of MR cisternography using three-dimensional half-fourier single-shot fast spin-echo sequences in the diagnosis of diseases related to cranial nerves VII and VIII

    International Nuclear Information System (INIS)

    Yamakami, Norio

    1999-01-01

    The purpose of this study was to evaluate the value of MR cisternography using three-dimensional half-Fourier single-shot fast spin-echo sequences in the diagnosis of diseasea related to cranial nerves VII and VIII. With a 0.5-T imager, the most appropriate setting of echo time and section thickness was first assessed in five volunteers. This resulted in echo time of 250 msec and section thickness of 2 mm as the most effective parameters. Second, using echo time of 120 msec and section thickness of 1.5 mm that were available from the beginning of this study, the demonstration of four nerves within the audistory canal was assessed in seven volunteers. In all of the volunteers, the facial, cochlear, and vestibular nerves were determined with demonstration of each of superior and inferior vestibular nerves in four of them. Next, MR cisternography using the same echo time and section thickness was applied in 368 patients with suspicion of acoustic neurinoma and 14 with hemifacial spasm. In 28 of the 368 patients, MR cisternograms depicted an acoustic neurinoma that was confirmed on postcontrast T1-weighted images. Meanwhile, in five of the 14 patients with hemifacial spasm, MR cisternograms revealed a vessel compressing the root exit zone of the affected facial nerve. It is concluded that MR cisternography using three-dimensional half-Fourier single-shot fast spin-echo sequences can be a useful means for demonstrating nerves within the auditory nerve as well as for the screening of acoustic neurionoma. (author)

  7. Single-shot measurements of low emittance beams from laser-plasma accelerators comparing two triggered injection methods

    Science.gov (United States)

    van Tilborg, Jeroen

    2017-10-01

    The success of laser plasma accelerator (LPA) based applications, such as a compact x-ray free electron laser (FEL), relies on the ability to produce electron beams with excellent 6D brightness, where brightness is defined as the ratio of charge to the product of the three normalized emittances. As such, parametric studies of the emittance of LPA generated electron beams are essential. Profiting from a stable and tunable LPA setup, combined with a carefully designed single-shot energy-dispersed emittance diagnostic, we present a direct comparison of charge dependent emittance measurements of electron beams generated by two different injection mechanisms: ionization injection and shock-induced density down-ramp injection. Both injection mechanisms have gained in popularity in recent years due to their demonstrated stable LPA performance. For the down-ramp injection configuration, normalized emittances a factor of two lower were recorded: less than 1 micron at spectral charge densities up to 2 pC/MeV. For both injection mechanisms, a contributing correlation of space charge to the emittance was identified. This measurement technique in general, and these results specifically, are critical to the evaluation of LPA injection methods and development of high-quality LPA beam lines worldwide. This work is supported by the U.S. DOE under Contract No. DE-AC02-05CH11231, by the U.S. DOE NNSA, DNN R&D (NA22), by the National Science Foundation under Grant No. PHY-1415596, and by the Gordon and Betty Moore Foundation under Grant ID GBMF4898.

  8. Signal to noise comparison of metabolic imaging methods on a clinical 3T MRI

    DEFF Research Database (Denmark)

    Müller, C. A.; Hansen, Rie Beck; Skinner, J. G.

    MRI with hyperpolarized tracers has enabled new diagnostic applications, e.g. metabolic imaging in cancer research. However, the acquisition of the transient, hyperpolarized signal with spatial and frequency resolution requires dedicated imaging methods. Here, we compare three promising candidate...... for 2D MR spectroscopic imaging (MRSI): (i) multi-echo balanced steady-state free precession (me-bSSFP), 1,2 (ii) echo planar spectroscopic imaging (EPSI) sequence and (iii) phase-encoded, pulseacquisition chemical-shift imaging (CSI)...

  9. Single shot “3-in-1” femoral nerve blockade with 0.25% or 0.375% levobupivacaine provides similar postoperative analgesia for total knee replacement

    OpenAIRE

    APAN, Alpaslan; SARI, Filiz; EKMEKÇİ, Alp Burak

    2010-01-01

    To compare postoperative analgesia provided by single shot "3-in-1" femoral nerve blockade using 0.25% or 0.375% levobupivacaine in preceding with spinal anesthesia for unilateral total knee replacement surgery. Materials and methods: Forty consenting patients undergoing unilateral total knee arthroplasty were included in this prospective randomized study. Spinal anesthesia was achieved with 15 mg plain bupivacaine at the L3-4 or L4-5 interspace. After resolution of the sp...

  10. Diffusion-weighted breast imaging at 3 T: Preliminary experience

    International Nuclear Information System (INIS)

    Nogueira, L.; Brandão, S.; Matos, E.; Nunes, R.G.; Ferreira, H.A.; Loureiro, J.; Ramos, I.

    2014-01-01

    Aim: To evaluate the performance of diffusion-weighted imaging (DWI) at 3 T for the detection and characterization of breast lesions. Materials and methods: Magnetic resonance imaging (MRI) of the breast, including DWI single-shot spin-echo echo planar images (SS-SE-EPI; eight b-values, 50–3000 s/mm 2 ), were acquired in women with a clinical indication for breast MRI. The exclusion criteria were as follows: (1) previous breast surgery, radiotherapy and/or chemotherapy within the prior 48 months (14 women); (2) only cystic lesions (one woman); (3) no detectable enhancing lesion at dynamic contrast-enhanced (DCE)-MRI (15 women); and (4) breast implants (four women). MRI results were corroborated by histopathology or imaging follow-up. Apparent diffusion coefficients (ADCs) were estimated for lesions and normal glandular tissue. Differences in the ADC between tissue types were evaluated and the sensitivity and specificity of the method calculated by receiver operating characteristics (ROC) curves. Results: The final cohort comprised 53 patients with 59 lesions. Histopathology was obtained for 58 lesions. One lesion was validated as benign on imaging follow-up. Mean ADCs of 1.99 ± 0.27 × 10 −3  mm 2 /s, 1.08 ± 0.25 × 10 −3  mm 2 /s, and 1.74 ± 0.35 × 10 −3  mm 2 /s were obtained for normal tissue, malignant, and benign lesions, respectively. Mean ADCs of malignancies were significantly lower than those of benign lesions (p < 0.001) and normal tissue (p < 0.0001). The sensitivity and specificity for stratifying lesions, considering an ADC threshold of 1.41 × 10 −3  mm 2 /s, were 94.3% and 87.5%, respectively; accuracy was 91.5%. Conclusion: DWI proved useful for the detection and characterization of breast lesions in the present sample. ADC values provide a high diagnostic performance for differentiation between benign and malignant lesions

  11. Differentiation between hepatic haemangiomas and cysts with an inversion recovery single-shot turbo spin-echo (SSTSE) sequence using the TI nulling value of hepatic haemangioma with sensitivity encoding

    International Nuclear Information System (INIS)

    Katada, Yoshiaki; Nozaki, Miwako; Yasumoto, Mayumi; Ishii, Chikako; Tanaka, Hiroshi; Nakamoto, Kazuya; Ohashi, Isamu

    2010-01-01

    To evaluate the additional value of inversion recovery (IR) single-shot turbo spin-echo (SSTSE) imaging with sensitivity encoding (SENSE) using the inversion time (TI) value of hepatic haemangioma as a supplement to conventional T2-weighted turbo spin-echo (TSE) imaging for the discrimination of hepatic haemangiomas and cysts. A total of 134 lesions (77 hepatic haemangiomas, 57 hepatic cysts) in 59 patients were evaluated. Three readers evaluated these images and used a five-point scale to evaluate the lesion status. A receiver operating characteristic (ROC) analysis and 2 x 2 table analysis were used. The ROC analysis for all the readers and all the cases revealed a significantly higher area under the curve (AUC) for the combination of moderately and heavily T2-weighted TSE with IR-SSTSE images (0.945) than for moderately and heavily T2-weighted TSE images alone (0.894) (P < 0.001). For the combination of T2-weighted TSE with IR-SSTSE versus T2-weighted TSE alone, the 2 x 2 table analysis revealed a higher true-positive rate; this difference was statistically significant (P < 0.0001). The introduction of IR-SSTSE with SENSE sequences significantly improves the diagnostic accuracy of the differentiation of hepatic haemangioma and cysts while increasing the time required for routine abdominal imaging by only 20 s. (orig.)

  12. Will the Real Benefits of Single-Shot Interscalene Block Please Stand Up? A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Abdallah, Faraj W; Halpern, Stephen H; Aoyama, Kazuyoshi; Brull, Richard

    2015-05-01

    Interscalene block (ISB) can provide pain relief after shoulder surgery, but a reliable quantification of its analgesic benefits is lacking. This meta-analysis examines the effect of single-shot ISB on analgesic outcomes during the first 48 hours after shoulder surgery. We retrieved randomized and quasirandomized controlled trials examining the analgesic benefits of ISB compared with none in shoulder surgery. Severity of postoperative pain measured on a visual analog scale (10 cm scale, 0 = no pain, 10 = worst pain) at rest at 24 hours was the designated primary outcome. Secondary outcomes included pain severity at rest and with motion at 2, 4, 6, 8, 12, 16, 32, 36, 40, and 48 hours postoperatively. Opioid consumption, postoperative nausea and vomiting, patient satisfaction with pain relief, and postanesthesia care unit and hospital discharge time were also assessed. A total of 23 randomized controlled trials, including 1090 patients, were analyzed. Patients in the ISB group had more severe postoperative pain at rest by a weighed mean difference (95% confidence interval) of 0.96 cm (0.08-1.83; P = 0.03) at 24 hours compared with no ISB, but there was no difference in pain severity beyond that point. The duration of pain relief at rest and with motion after ISB were 8 and 6 hours, respectively, with a corresponding weighed mean difference in visual analog scale pain scores (99% confidence interval) of -1.59 cm (-2.60 to -0.58) and -2.20 cm (-4.34 to -0.06), respectively, with no additional pain relief benefits beyond these points. ISB reduced postoperative opioid consumption up to 12 hours, decreased postoperative nausea and vomiting at 24 hours, and expedited postanesthesia care unit and hospital discharge. The type, dose, and volume of local anesthetic used did not affect the results. ISB can provide effective analgesia up to 6 hours with motion and 8 hours at rest after shoulder surgery, with no demonstrable benefits thereafter. Patients who receive an ISB can

  13. Isotropic resolution diffusion tensor imaging of lumbosacral and sciatic nerves using a phase-corrected diffusion-prepared 3D turbo spin echo.

    Science.gov (United States)

    Cervantes, Barbara; Van, Anh T; Weidlich, Dominik; Kooijman, Hendrick; Hock, Andreas; Rummeny, Ernst J; Gersing, Alexandra; Kirschke, Jan S; Karampinos, Dimitrios C

    2018-08-01

    To perform in vivo isotropic-resolution diffusion tensor imaging (DTI) of lumbosacral and sciatic nerves with a phase-navigated diffusion-prepared (DP) 3D turbo spin echo (TSE) acquisition and modified reconstruction incorporating intershot phase-error correction and to investigate the improvement on image quality and diffusion quantification with the proposed phase correction. Phase-navigated DP 3D TSE included magnitude stabilizers to minimize motion and eddy-current effects on the signal magnitude. Phase navigation of motion-induced phase errors was introduced before readout in 3D TSE. DTI of lower back nerves was performed in vivo using 3D TSE and single-shot echo planar imaging (ss-EPI) in 13 subjects. Diffusion data were phase-corrected per k z plane with respect to T 2 -weighted data. The effects of motion-induced phase errors on DTI quantification was assessed for 3D TSE and compared with ss-EPI. Non-phase-corrected 3D TSE resulted in artifacts in diffusion-weighted images and overestimated DTI parameters in the sciatic nerve (mean diffusivity [MD] = 2.06 ± 0.45). Phase correction of 3D TSE DTI data resulted in reductions in all DTI parameters (MD = 1.73 ± 0.26) of statistical significance (P ≤ 0.001) and in closer agreement with ss-EPI DTI parameters (MD = 1.62 ± 0.21). DP 3D TSE with phase correction allows distortion-free isotropic diffusion imaging of lower back nerves with robustness to motion-induced artifacts and DTI quantification errors. Magn Reson Med 80:609-618, 2018. © 2018 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. © 2018 The Authors Magnetic Resonance

  14. LiNbO/sub 3/:Ti directional-coupler modulators for high-bandwidth, single-shot instrumentation systems operating at 800 nm

    International Nuclear Information System (INIS)

    Lowry, M.; Jander, D.; Lancaster, G.; Kwiat, P.; McWright, G.; Peterson, R.T.; Tindall, W.; Roeske, F.

    1987-01-01

    The authors update their work on optical directional-coupler modulators (ODCMs) for single-shot, analog instrumentation systems operating at -- 800 nm. They can now fabricate directional-coupler devices that have one input and two output pigtails with insertion losses of 8.9 dB on average. Data for the ODCMs indicate an impulse response of less than 40 ps. They have implemented these devices in an ultrafast, x-ray measurement system. They discuss our data from this implementation and their implications for continued ODCM development

  15. Quantitative evaluation of benign and malignant vertebral fractures with diffusion-weighted MRI: what is the optimum combination of b values for ADC-based lesion differentiation with the single-shot turbo spin-echo sequence?

    Science.gov (United States)

    Geith, Tobias; Schmidt, Gerwin; Biffar, Andreas; Dietrich, Olaf; Duerr, Hans Roland; Reiser, Maximilian; Baur-Melnyk, Andrea

    2014-09-01

    The purpose of our study was to determine the optimum combination of b values for calculating the apparent diffusion coefficient (ADC) using a diffusion-weighted (DW) single-shot turbo spin-echo (TSE) sequence in the differentiation between acute benign and malignant vertebral body fractures. Twenty-six patients with osteoporotic (mean age, 69 years; range, 31.5-86.2 years) and 20 patients with malignant vertebral fractures (mean age, 63.4 years; range, 24.7-86.4 years) were studied. T1-weighted, STIR, and T2-weighted sequences were acquired at 1.5 T. A DW single-shot TSE sequence at different b values (100, 250, 400, and 600 s/mm(2)) was applied. On the DW images for each evaluated fracture, an ROI was manually adapted to the area of hyperintense signal intensity on STIR-hypointense signal on T1-weighted images. For each ROI, nine different combinations of two, three, and four b values were used to calculate the ADC using a least-squares algorithm. The Student t test and Mann-Whitney U test were used to determine significant differences between benign and malignant fractures. An ROC analysis and the Youden index were used to determine cutoff values for assessment of the highest sensitivity and specificity for the different ADC values. The positive (PPV) and negative predictive values (NPV) were also determined. All calculated ADCs (except the combination of b = 400 s/mm(2) and b = 600 s/mm(2)) showed statistically significant differences between benign and malignant vertebral body fractures, with benign fractures having higher ADCs than malignant ones. The use of higher b values resulted in lower ADCs than those calculated with low b values. The highest AUC (0.85) showed the ADCs calculated with b = 100 and 400 s/mm(2), and the second highest AUC (0.829) showed the ADCs calculated with b = 100, 250, and 400 s/mm(2). The Youden index with equal weight given to sensitivity and specificity suggests use of an ADC calculated with b = 100, 250, and 400 s/mm(2) (cutoff

  16. Evaluation of a multiple spin- and gradient-echo (SAGE) EPI acquisition with SENSE acceleration: applications for perfusion imaging in and outside the brain.

    Science.gov (United States)

    Skinner, Jack T; Robison, Ryan K; Elder, Christopher P; Newton, Allen T; Damon, Bruce M; Quarles, C Chad

    2014-12-01

    Perfusion-based changes in MR signal intensity can occur in response to the introduction of exogenous contrast agents and endogenous tissue properties (e.g. blood oxygenation). MR measurements aimed at capturing these changes often implement single-shot echo planar imaging (ssEPI). In recent years ssEPI readouts have been combined with parallel imaging (PI) to allow fast dynamic multi-slice imaging as well as the incorporation of multiple echoes. A multiple spin- and gradient-echo (SAGE) EPI acquisition has recently been developed to allow measurement of transverse relaxation rate (R2 and R2(*)) changes in dynamic susceptibility contrast (DSC)-MRI experiments in the brain. With SAGE EPI, the use of PI can influence image quality, temporal resolution, and achievable echo times. The effect of PI on dynamic SAGE measurements, however, has not been evaluated. In this work, a SAGE EPI acquisition utilizing SENSE PI and partial Fourier (PF) acceleration was developed and evaluated. Voxel-wise measures of R2 and R2(*) in healthy brain were compared using SAGE EPI and conventional non-EPI multiple echo acquisitions with varying SENSE and PF acceleration. A conservative SENSE factor of 2 with PF factor of 0.73 was found to provide accurate measures of R2 and R2(*) in white (WM) (rR2=[0.55-0.79], rR2*=[0.47-0.71]) and gray (GM) matter (rR2=[0.26-0.59], rR2*=[0.39-0.74]) across subjects. The combined use of SENSE and PF allowed the first dynamic SAGE EPI measurements in muscle, with a SENSE factor of 3 and PF factor of 0.6 providing reliable relaxation rate estimates when compared to multi-echo methods. Application of the optimized SAGE protocol in DSC-MRI of high-grade glioma patients provided T1 leakage-corrected estimates of CBV and CBF as well as mean vessel diameter (mVD) and simultaneous measures of DCE-MRI parameters K(trans) and ve. Likewise, application of SAGE in a muscle reperfusion model allowed dynamic measures of R2', a parameter that has been shown to correlate

  17. High-grade and low-grade gliomas: differentiation by using perfusion MR imaging

    International Nuclear Information System (INIS)

    Hakyemez, B.; Erdogan, C.; Ercan, I.; Ergin, N.; Uysal, S.; Atahan, S.

    2005-01-01

    AIM: Relative cerebral blood volume (rCBV) is a commonly used perfusion magnetic resonance imaging (MRI) technique for the evaluation of tumour grade. Relative cerebral blood flow (rCBF) has been less studied. The goal of our study was to determine the usefulness of these parameters in evaluating the histopathological grade of the cerebral gliomas. METHODS: This study involved 33 patients (22 high-grade and 11 low-grade glioma cases). MRI was performed for all tumours by using a first-passage gadopentetate dimeglumine T2*-weighted gradient-echo single-shot echo-planar sequence followed by conventional MRI. The rCBV and rCBF were calculated by deconvolution of an arterial input function. The rCBV and rCBF ratios of the lesions were obtained by dividing the values obtained from the normal white matter of the contralateral hemisphere. For statistical analysis Mann-Whitney testing was carried out. A p value of less than 0.05 indicated a statistically significant difference. Receiver operating characteristic curve (ROC) analysis was performed to assess the relationship between the rCBV and rCBF ratios and grade of gliomas. Their cut-off value permitting discrimination was calculated. The correlation between rCBV and CBF ratios and glioma grade was assessed using Pearson correlation analysis. RESULTS: In high-grade gliomas, rCBV and rCBF ratios were measured as 6.50±4.29 and 3.32±1.87 (mean±SD), respectively. In low-grade gliomas, rCBV and rCBF ratios were 1.69±0.51 and 1.16±0.38, respectively. The rCBV and rCBF ratios for high-grade gliomas were statistically different from those of low-grade gliomas (p 0.05). The cut-off value was taken as 1.98 in the rCBV ratio and 1.25 in the rCBF ratio. There was a strong correlation between the rCBV and CBF ratios (Pearson correlation = 0.830, p<0.05). CONCLUSION: Perfusion MRI is useful in the preoperative assessment of the histopathologicalal grade of gliomas; the rCBF ratio in addition to the rCBV ratio can be incorporated

  18. Diffusion-weighted magnetic resonance imaging of femoral head osteonecrosis in two groups of patients: Legg-Perthes-Calve and Avascular necrosis.

    Science.gov (United States)

    Ozel, Betul Duran; Ozel, Deniz; Ozkan, Fuat; Halefoglu, Ahmet M

    2016-03-01

    The aim of this prospective study was to evaluate the value of diffusion-weighted magnetic resonance imaging (DW-MRI) in patients with osteonecrosis. Patients were divided into two subgroups as avascular necrosis (AVN) of femoral head for adult group and Legg-Calvé-Perthes (LCP) patients for children. Seventeen patients with femoral head AVN (mean age 42.3 years) and 17 patients with LCP (mean age 8.2 years) were included in this study. Diagnosis confirmed with clinical and other imaging procedures among the patients complaining hip pain. DW images were obtained using the single-shot echo planar sequence and had b values of 0, 500, 1000 s/mm(2). The apparent diffusion coefficient (ADC) values were measured from ADC maps in epiphysis of patients with AVN, both from metaphysis and epiphysis in patients with LCP, respectively. Mann-Whitney U test was used to compare ADC values. The mean ADC value of femoral heads (1.285 ± 0.204 × 10(-3) mm(2)/s) was increased in patients with AVN when compared to normal bone tissue (0.209 ± 0.214 × 10(-3) mm(2)/s) (p < 0.01). The mean ADC values (×10(-3) mm(2)/s) of both metaphysis (0.852 ± 0.293) and epiphysis (0.843 ± 0.332) were also increased in patients with LCP and differences were statistically significant (p < 0.01). As a result, osteonecrosis shows increased ADC values. But it is a controversial concept that DWI offers a valuable data to conventional MRI or not. However, as there are report states, there is a correlation between the stage of the disease with ADC values in the LCP disease. DWI is a fast, without-contrast administration technique and provides quantitative values additional to conventional MR techniques; we believe DWI may play an additional assistance to the diagnosis and treatment for LCP patients. Multicentric larger group studies may provide additional data to this issue.

  19. What is the most suitable MR signal index for quantitative evaluation of placental function using Half-Fourier acquisition single-shot turbo spin-echo compared with T2-relaxation time?

    Science.gov (United States)

    Kameyama, Kyoko Nakao; Kido, Aki; Himoto, Yuki; Moribata, Yusaku; Minamiguchi, Sachiko; Konishi, Ikuo; Togashi, Kaori

    2018-06-01

    Background Half-Fourier acquisition single-shot turbo spin-echo (HASTE) imaging is now widely used for placental and fetal imaging because of its rapidity and low sensitivity to fetal movement. If placental dysfunction is also predicted by quantitative value obtained from HASTE image, then it might be beneficial for evaluating placental wellbeing. Purpose To ascertain the most suitable magnetic resonance (MR) signal indexes reflecting placental function using HASTE imaging. Material and Methods This retrospective study included 37 consequent patients who had given informed consent to MR imaging (MRI) examinations. All had undergone MRI examinations between February 2014 and June 2015. First, the correlation between T2-relaxation time of normal placenta and gestational age (GA) was examined. Second, correlation between signal intensity ratios (SIRs) using HASTE imaging and placental T2-relaxation time were assessed. The SIRs were calculated using placental signal intensity (SI) relative to the SI of the amniotic fluid, fetal ocular globes, gastric fluid, bladder, maternal psoas major muscles, and abdominal subcutaneous adipose tissue. Results Among the 37 patients, the correlation between T2-relaxation time of the 25 normal placentas and GA showed a moderately strong correlation (Spearman rho = -0.447, P = 0.0250). The most significant correlation with placental T2-relaxation time was observed with the placental SIR relative to the maternal psoas major muscles (SIR pl./psoas muscle ) (Spearman rho = -0.531, P = 0.0007). Conclusion This study revealed that SIR pl./psoas muscle showed the best correlation to placental T2-relaxation time. Results show that SIR pl./psoas muscle might be optimal as a clinically available quantitative index of placental function.

  20. Combined prospective and retrospective correction to reduce motion-induced image misalignment and geometric distortions in EPI.

    Science.gov (United States)

    Ooi, Melvyn B; Muraskin, Jordan; Zou, Xiaowei; Thomas, William J; Krueger, Sascha; Aksoy, Murat; Bammer, Roland; Brown, Truman R

    2013-03-01

    Despite rigid-body realignment to compensate for head motion during an echo-planar imaging time-series scan, nonrigid image deformations remain due to changes in the effective shim within the brain as the head moves through the B(0) field. The current work presents a combined prospective/retrospective solution to reduce both rigid and nonrigid components of this motion-related image misalignment. Prospective rigid-body correction, where the scan-plane orientation is dynamically updated to track with the subject's head, is performed using an active marker setup. Retrospective distortion correction is then applied to unwarp the remaining nonrigid image deformations caused by motion-induced field changes. Distortion correction relative to a reference time-frame does not require any additional field mapping scans or models, but rather uses the phase information from the echo-planar imaging time-series itself. This combined method is applied to compensate echo-planar imaging scans of volunteers performing in-plane and through-plane head motions, resulting in increased image stability beyond what either prospective or retrospective rigid-body correction alone can achieve. The combined method is also assessed in a blood oxygen level dependent functional MRI task, resulting in improved Z-score statistics. Copyright © 2012 Wiley Periodicals, Inc.

  1. Lowering of L10 phase transition temperature of FePt thin films by single shot H+ ion exposure using plasma focus device

    International Nuclear Information System (INIS)

    Pan, Z.Y.; Lin, J.J.; Zhang, T.; Karamat, S.; Tan, T.L.; Lee, P.; Springham, S.V.; Ramanujan, R.V.; Rawat, R.S.

    2009-01-01

    FePt thin films are exposed to pulsed energetic H + ion beam from plasma focus. In irradiated films, the phase transition from the low K u disordered face-centered-cubic structure to high K u ordered face-centered-tetragonal phase was achieved at 400 deg. C with the order parameter S ranging from 0.73 to 0.83, high coercivity of about 5356 kA/m, high negative nucleation field of about 7700 kA/m and high squareness ratio ranging from 0.73 to 0.79. The advantage of using plasma focus device is that it can lower phase transition temperature and significantly enhance the magnetic properties by a pulsed single shot exposure

  2. Single-shot full strain tensor determination with microbeam X-ray Laue diffraction and a two-dimensional energy-dispersive detector.

    Science.gov (United States)

    Abboud, A; Kirchlechner, C; Keckes, J; Conka Nurdan, T; Send, S; Micha, J S; Ulrich, O; Hartmann, R; Strüder, L; Pietsch, U

    2017-06-01

    The full strain and stress tensor determination in a triaxially stressed single crystal using X-ray diffraction requires a series of lattice spacing measurements at different crystal orientations. This can be achieved using a tunable X-ray source. This article reports on a novel experimental procedure for single-shot full strain tensor determination using polychromatic synchrotron radiation with an energy range from 5 to 23 keV. Microbeam X-ray Laue diffraction patterns were collected from a copper micro-bending beam along the central axis (centroid of the cross section). Taking advantage of a two-dimensional energy-dispersive X-ray detector (pnCCD), the position and energy of the collected Laue spots were measured for multiple positions on the sample, allowing the measurement of variations in the local microstructure. At the same time, both the deviatoric and hydrostatic components of the elastic strain and stress tensors were calculated.

  3. Label-free nanoscale characterization of red blood cell structure and dynamics using single-shot transport of intensity equation

    Science.gov (United States)

    Poola, Praveen Kumar; John, Renu

    2017-10-01

    We report the results of characterization of red blood cell (RBC) structure and its dynamics with nanometric sensitivity using transport of intensity equation microscopy (TIEM). Conventional transport of intensity technique requires three intensity images and hence is not suitable for studying real-time dynamics of live biological samples. However, assuming the sample to be homogeneous, phase retrieval using transport of intensity equation has been demonstrated with single defocused measurement with x-rays. We adopt this technique for quantitative phase light microscopy of homogenous cells like RBCs. The main merits of this technique are its simplicity, cost-effectiveness, and ease of implementation on a conventional microscope. The phase information can be easily merged with regular bright-field and fluorescence images to provide multidimensional (three-dimensional spatial and temporal) information without any extra complexity in the setup. The phase measurement from the TIEM has been characterized using polymeric microbeads and the noise stability of the system has been analyzed. We explore the structure and real-time dynamics of RBCs and the subdomain membrane fluctuations using this technique.

  4. Advanced Magnetic Resonance Imaging techniques to probe muscle structure and function

    Science.gov (United States)

    Malis, Vadim

    Structural and functional Magnetic Resonance Imaging (MRI) studies of skeletal muscle allow the elucidation of muscle physiology under normal and pathological conditions. Continuing on the efforts of the Muscle Imaging and Modeling laboratory, the focus of the thesis is to (i) extend and refine two challenging imaging modalities: structural imaging using Diffusion Tensor Imaging (DTI) and functional imaging based on Velocity Encoded Phase Contrast Imaging (VE-PC) and (ii) apply these methods to explore age related structure and functional differences of the gastrocnemius muscle. Diffusion Tensor Imaging allows the study of tissue microstructure as well as muscle fiber architecture. The images, based on an ultrafast single shot Echo Planar Imaging (EPI) sequence, suffer from geometric distortions and low signal to noise ratio. A processing pipeline was developed to correct for distortions and to improve image Signal to Noise Ratio (SNR). DTI acquired on a senior and young cohort of subjects were processed through the pipeline and differences in DTI derived indices and fiber architecture between the two cohorts were explored. The DTI indices indicated that at the microstructural level, fiber atrophy was accompanied with a reduction in fiber volume fraction. At the fiber architecture level, fiber length and pennation angles decreased with age that potentially contribute to the loss of muscle force with age. Velocity Encoded Phase Contrast imaging provides tissue (e.g. muscle) velocity at each voxel which allows the study of strain and Strain Rate (SR) under dynamic conditions. The focus of the thesis was to extract 2D strain rate tensor maps from the velocity images and apply the method to study age related differences. The tensor mapping can potentially provide unique information on the extracellular matrix and lateral transmission the role of these two elements has recently emerged as important determinants of force loss with age. In the cross sectional study on

  5. Optimization of mass spectrometric parameters improve the identification performance of capillary zone electrophoresis for single-shot bottom-up proteomics analysis.

    Science.gov (United States)

    Zhang, Zhenbin; Dovichi, Norman J

    2018-02-25

    The effects of MS1 injection time, MS2 injection time, dynamic exclusion time, intensity threshold, and isolation width were investigated on the numbers of peptide and protein identifications for single-shot bottom-up proteomics analysis using CZE-MS/MS analysis of a Xenopus laevis tryptic digest. An electrokinetically pumped nanospray interface was used to couple a linear-polyacrylamide coated capillary to a Q Exactive HF mass spectrometer. A sensitive method that used a 1.4 Th isolation width, 60,000 MS2 resolution, 110 ms MS2 injection time, and a top 7 fragmentation produced the largest number of identifications when the CZE loading amount was less than 100 ng. A programmable autogain control method (pAGC) that used a 1.4 Th isolation width, 15,000 MS2 resolution, 110 ms MS2 injection time, and top 10 fragmentation produced the largest number of identifications for CZE loading amounts greater than 100 ng; 7218 unique peptides and 1653 protein groups were identified from 200 ng by using the pAGC method. The effect of mass spectrometer conditions on the performance of UPLC-MS/MS was also investigated. A fast method that used a 1.4 Th isolation width, 30,000 MS2 resolution, 45 ms MS2 injection time, and top 12 fragmentation produced the largest number of identifications for 200 ng UPLC loading amount (6025 unique peptides and 1501 protein groups). This is the first report where the identification number for CZE surpasses that of the UPLC at the 200 ng loading level. However, more peptides (11476) and protein groups (2378) were identified by using UPLC-MS/MS when the sample loading amount was increased to 2 μg with the fast method. To exploit the fast scan speed of the Q-Exactive HF mass spectrometer, higher sample loading amounts are required for single-shot bottom-up proteomics analysis using CZE-MS/MS. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Development of Compton X-ray spectrometer for high energy resolution single-shot high-flux hard X-ray spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Kojima, Sadaoki, E-mail: kojima-s@ile.osaka-u.ac.jp, E-mail: sfujioka@ile.osaka-u.ac.jp; Ikenouchi, Takahito; Arikawa, Yasunobu; Sakata, Shohei; Zhang, Zhe; Abe, Yuki; Nakai, Mitsuo; Nishimura, Hiroaki; Shiraga, Hiroyuki; Fujioka, Shinsuke, E-mail: kojima-s@ile.osaka-u.ac.jp, E-mail: sfujioka@ile.osaka-u.ac.jp; Azechi, Hiroshi [Institute of Laser Engineering, Osaka University, 2-6 Yamada-oka, Suita, Osaka 565-0871 (Japan); Ozaki, Tetsuo [National Institute for Fusion Science, 322-6 Oroshi, Toki, Gifu 509-5292 (Japan); Miyamoto, Shuji; Yamaguchi, Masashi; Takemoto, Akinori [Laboratory of Advanced Science and Technology for Industry, University of Hyogo, 3-1-2 Kouto, Kamigori-cho, Ako-gun, Hyogo 678-1205 (Japan)

    2016-04-15

    Hard X-ray spectroscopy is an essential diagnostics used to understand physical processes that take place in high energy density plasmas produced by intense laser-plasma interactions. A bundle of hard X-ray detectors, of which the responses have different energy thresholds, is used as a conventional single-shot spectrometer for high-flux (>10{sup 13} photons/shot) hard X-rays. However, high energy resolution (Δhv/hv < 0.1) is not achievable with a differential energy threshold (DET) X-ray spectrometer because its energy resolution is limited by energy differences between the response thresholds. Experimental demonstration of a Compton X-ray spectrometer has already been performed for obtaining higher energy resolution than that of DET spectrometers. In this paper, we describe design details of the Compton X-ray spectrometer, especially dependence of energy resolution and absolute response on photon-electron converter design and its background reduction scheme, and also its application to the laser-plasma interaction experiment. The developed spectrometer was used for spectroscopy of bremsstrahlung X-rays generated by intense laser-plasma interactions using a 200 μm thickness SiO{sub 2} converter. The X-ray spectrum obtained with the Compton X-ray spectrometer is consistent with that obtained with a DET X-ray spectrometer, furthermore higher certainly of a spectral intensity is obtained with the Compton X-ray spectrometer than that with the DET X-ray spectrometer in the photon energy range above 5 MeV.

  7. Highly Resolved Mg/Ca Depth Profiles of Planktic Foraminifer test Walls Using Single shot Measurements of fs-LA-ICPMS

    Science.gov (United States)

    Jochum, K. P.; Schiebel, R.; Stoll, B.; Weis, U.; Haug, G. H.

    2017-12-01

    Foraminifers are sensitive archives of changes in climate and marine environment. It has been shown that the Mg/Ca signal is a suitable proxy of seawater temperature, because the incorporation of Mg depends on ambient water temperature. In contrast to most former studies, where this ratio is determined by solution-based bulk analysis of 20 - 30 specimens, we have investigated Mg/Ca in single specimens and single chambers at high resolution. A new fs-200 nm-LA-ICPMS technique was developed for the µm-sized layered calcite shells. To generate depth profiles with a resolution of about 50 nm/shot, we chose a low fluence of about 0.3 Jcm-2 and performed single shot measurements of the double charged 44Ca++ and the single charged 25Mg+ ions together. Precision (RSD) of the Mg/Ca data is about 5 %. Calibration was performed with the carbonate reference material MACS-3 from the USGS. Our results for different species from the Arabian Sea and Caribbean Sea demonstrate that Mg/Ca of different chambers vary and indicate that the foraminifer individuals built their chambers in different water depths and/or experienced seasonal changes in seawater temperature caused, for example, by upwelling (cold) versus stratified (warm) conditions. Typically, the Mg/Ca ratios of the final two chambers of the planktic foraminifer Globorotalia menardii from a sediment core of the Arabian Sea differ by about 5 mmol/mol from earlier chambers (2 mmol/mol) corresponding to seawater temperatures of 28 °C and 18 °C, respectively. In addition, mass fractions of other elements like Sr, Mn, Fe, Ba, and U have been determined with fs-LA-ICPMS using fast line scans, and thus provide further insights in the ecology of foraminifers.

  8. Fast method of NMR imaging based on trains of spin echoes

    International Nuclear Information System (INIS)

    Hennel, F.

    1993-01-01

    A theoretical introduction to Fourier NMR imaging and a discussion of fast methods are presented. Then an application of the method of echo-planar imaging (EPI) with spin echoes in a micro-imaging system is described together with introduced modifications of the sequence. A new technique for the measurement of flow profiles in liquids which results from a modification of x-pulsed EPI is presented. The development of new software for a NMR micro-imaging system is described, too. 51 refs, 29 refs

  9. Comparison and Optimization of 3.0 T Breast Images Quality of Diffusion-Weighted Imaging with Multiple B-Values.

    Science.gov (United States)

    Han, Xiaowei; Li, Junfeng; Wang, Xiaoyi

    2017-04-01

    Breast 3.0 T magnetic resonance diffusion-weighted imaging (MR-DWI) of benign and malignant lesions were obtained to measure and calculate the signal-to-noise ratio (SNR), signal intensity ratio (SIR), and contrast-to-noise ratio (CNR) of lesions at different b-values. The variation patterns of SNR and SIR were analyzed with different b-values and the images of DWI were compared at four different b-values with higher image quality. The effect of SIR on the differential diagnostic efficiency of benign and malignant lesions was compared using receiver operating characteristic curves to provide a reference for selecting the optimal b-value. A total of 96 qualified patients with 112 lesions and 14 patients with their contralateral 14 normal breasts were included in this study. The single-shot echo planar imaging sequence was used to perform the DWI and a total of 13 b-values were used: 0, 50, 100, 200, 400, 600, 800, 1000, 1200, 1500, 1800, 2000, and 2500 s/mm 2 . On DWI, the suitable regions of interest were selected. The SNRs of normal breasts (SNR normal ), SNR lesions , SIR, and CNR of benign and malignant lesions were measured on DWI with different b-values and calculated. The variation patterns of SNR, SIR, and CNR values on DWI for normal breasts, benign lesions, and malignant lesions with different b-values were analyzed by using Pearson correlation analysis. The SNR and SIR of benign and malignant lesions with the same b-values were compared using t-tests. The diagnostic efficiencies of SIR with different b-values for benign and malignant lesions were evaluated using receiver operating characteristic curves. Breast DWI had higher CNR for b-values ranging from 600 to 1200 s/mm 2 . It had the best CNR at b = 1000 s/mm 2 for the benign lesions and at b = 1200 s/mm 2 for the malignant lesions. The signal intensity and SNR values of normal breasts decreased with increasing b-values, with a negative correlation (r = -0.945, P < 0.01). The

  10. Fast spin-echo imaging

    International Nuclear Information System (INIS)

    Mackey, K.; Zoarski, G.; Bentson, J.R.; Lufkin, R.B.; Melki, P.; Jolesz, F.

    1991-01-01

    This paper reports on a partial radio-frequency (RF) echo-planar pulse sequence called contiguous slice fast spin echo (CSFSE) which is undergoing clinical trials for spine MR imaging. In this variation of rapid acquisition relaxation enhanced (RARE) spin-echo imaging, rapid 180 degrees RF pulse generated refocused echoes, producing T2-weighted images in about one-third the time of conventional double-echo technique. Forty patients with suspected pathology of the spine were imaged with conventional double-echo and closely matched CSFSE techniques on a GE Signa 1.5-T Advantage system. Cases were reviewed by two board-certified neuroradiologists. In all cases the CSFSE images were of equal or superior quality compared with those obtained with the conventional double-echo technique. Pathologic processes that were imaged consisted of inflammatory, neoplastic, posttraumatic, and degenerative conditions

  11. Single-Shot-RARE for rapid 3D hyperpolarized metabolic ex vivo tissue imaging: RF-pulse design for semi-dense spectra

    DEFF Research Database (Denmark)

    Magnusson, P.O.; Jensen, Pernille Rose; Dyrby, Tim Bjørn

    MRS of hyperpolarized (HP) 13C-enriched compounds is a promising method for in vivo cancer diagnosis . Sentinel lymph node ex vivo tissue sample histology used in clinical routine for breast cancer metastasis diagnosis requires time consuming sample analysis. 3D-HP-MRSI can potentially speed up...

  12. Intra-Articular, Single-Shot Hylan G-F 20 Hyaluronic Acid Injection Compared with Corticosteroid in Knee Osteoarthritis: A Double-Blind, Randomized Controlled Trial.

    Science.gov (United States)

    Tammachote, Nattapol; Kanitnate, Supakit; Yakumpor, Thanasak; Panichkul, Phonthakorn

    2016-06-01

    The treatment of knee osteoarthritis with hyaluronic acid or corticosteroid injection has been widely used. The purpose of this study was to compare the efficacy of hyaluronic acid (hylan G-F 20) with triamcinolone acetonide as a single intra-articular injection for knee osteoarthritis. This study was a prospective, randomized, double-blind clinical trial. Participants with symptomatic knee osteoarthritis were recruited. They were randomized to receive a single-shot, intra-articular injection of either 6 mL of hylan G-F 20 or 6 mL of a solution comprising 1 mL of 40-mg triamcinolone acetonide and 5 mL of 1% lidocaine with epinephrine. The primary outcomes were knee pain severity, knee function, and range of motion at 6 months. Ninety-nine patients were assessed before injection and underwent a 6-month follow-up. Patients and evaluators were blinded. Multilevel regression models were used to estimate differences between the groups. At the 6-month follow-up, compared with patients who took hylan G-F 20, patients who took triamcinolone acetonide had similar improvement in knee pain, knee function, and range of motion. The difference in mean outcome scores between groups was, with regard to knee pain, a visual analog scale (VAS) score of 3 points (95% confidence interval [95% CI], -6 to 11 points); with regard to knee function, a modified Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score of 0 points (95% CI, -8 to 6 points); and, with regard to range of motion, flexion of -1° (95% CI, -5° to 2°) and extension of 0° (95% CI, -0.5° to 0.5°). However, patients who took triamcinolone acetonide had better pain improvement from 24 hours until 1 week after injection; the mean difference between groups with regard to the VAS score was 12 points (95% CI, 5 to 20 points; p = 0.002) at 24 hours and 9 points (95% CI, 1 to 15 points; p = 0.018) at 1 week. At 2 weeks after injection, patients who took triamcinolone acetonide also had better knee

  13. Sequential interactions-in which one player plays first and another responds-promote cooperation in evolutionary-dynamical simulations of single-shot Prisoner's Dilemma and Snowdrift games.

    Science.gov (United States)

    Laird, Robert A

    2018-05-21

    Cooperation is a central topic in evolutionary biology because (a) it is difficult to reconcile why individuals would act in a way that benefits others if such action is costly to themselves, and (b) it underpins many of the 'major transitions of evolution', making it essential for explaining the origins of successively higher levels of biological organization. Within evolutionary game theory, the Prisoner's Dilemma and Snowdrift games are the main theoretical constructs used to study the evolution of cooperation in dyadic interactions. In single-shot versions of these games, wherein individuals play each other only once, players typically act simultaneously rather than sequentially. Allowing one player to respond to the actions of its co-player-in the absence of any possibility of the responder being rewarded for cooperation or punished for defection, as in simultaneous or sequential iterated games-may seem to invite more incentive for exploitation and retaliation in single-shot games, compared to when interactions occur simultaneously, thereby reducing the likelihood that cooperative strategies can thrive. To the contrary, I use lattice-based, evolutionary-dynamical simulation models of single-shot games to demonstrate that under many conditions, sequential interactions have the potential to enhance unilaterally or mutually cooperative outcomes and increase the average payoff of populations, relative to simultaneous interactions-benefits that are especially prevalent in a spatially explicit context. This surprising result is attributable to the presence of conditional strategies that emerge in sequential games that can't occur in the corresponding simultaneous versions. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Basic concepts from magnetic resonance imaging

    International Nuclear Information System (INIS)

    Rodriguez Arroyo, Diego

    2011-01-01

    The use of magnetic resonance imaging (MRI) has grown exponentially, due in part to excellent anatomic and pathologic detail provided by the modality, as recent technological advances that have led to more rapid acquisition times. Radiology residents in different parts of the world now receive training in MR images from their first year of residence, included the pulse sequences training spin-echo, gradient-echo, inversion-recovery, echo-planar image and MR angiographic sequences, commonly used in medical imaging. However, to optimize the use of this type of study, it has been necessary to understand the basic concepts of physics, included the concepts of recovery T1, degradation T2* and T2, repetition time, echo time, and the effects of chemical shift. Additionally, it has been important to understand the contrast weighting for better representation of specific tissues and thus perform an appropriate differential diagnosis of various pathological processes. (author) [es

  15. Clinical evaluation of pulmonary perfusion MRI using FAIR (flow-sensitive alternating inversion recovery)-HASTE (Half-Fourier Single-Shot TurboSE) method

    International Nuclear Information System (INIS)

    Togami, Izumi; Sasai, Nobuya; Tsunoda, Masatoshi; Sei, Tetsurou; Sato, Shuhei; Yabuki, Takayuki; Hiraki, Yoshio

    2002-01-01

    The FAIR-HASTE method is a kind of noninvasive perfusion MR imaging obtained without the use of contrast media. By subtracting a flow-insensitive image from a flow-sensitive image, contrast enhancement of inflowing blood achieved. In the present study, we applied pulmonary perfusion FAIR-HASTE sequence for 23 patients with various pulmonary diseases, and compared the findings with those by pulmonary perfusion scintigraphy and Gadolinium perfusion MRI. Pulmonary perfusion imaging with the FAIR-HASTE method was possible in all clinical cases, and the findings corresponded well to those obtained by perfusion MRI using contrast media or pulmonary scintigraphy. The FAIR-HASTE method is a promising method for the evaluation of pulmonary perfusion. (author)

  16. A subspace approach to high-resolution spectroscopic imaging.

    Science.gov (United States)

    Lam, Fan; Liang, Zhi-Pei

    2014-04-01

    To accelerate spectroscopic imaging using sparse sampling of (k,t)-space and subspace (or low-rank) modeling to enable high-resolution metabolic imaging with good signal-to-noise ratio. The proposed method, called SPectroscopic Imaging by exploiting spatiospectral CorrElation, exploits a unique property known as partial separability of spectroscopic signals. This property indicates that high-dimensional spectroscopic signals reside in a very low-dimensional subspace and enables special data acquisition and image reconstruction strategies to be used to obtain high-resolution spatiospectral distributions with good signal-to-noise ratio. More specifically, a hybrid chemical shift imaging/echo-planar spectroscopic imaging pulse sequence is proposed for sparse sampling of (k,t)-space, and a low-rank model-based algorithm is proposed for subspace estimation and image reconstruction from sparse data with the capability to incorporate prior information and field inhomogeneity correction. The performance of the proposed method has been evaluated using both computer simulations and phantom studies, which produced very encouraging results. For two-dimensional spectroscopic imaging experiments on a metabolite phantom, a factor of 10 acceleration was achieved with a minimal loss in signal-to-noise ratio compared to the long chemical shift imaging experiments and with a significant gain in signal-to-noise ratio compared to the accelerated echo-planar spectroscopic imaging experiments. The proposed method, SPectroscopic Imaging by exploiting spatiospectral CorrElation, is able to significantly accelerate spectroscopic imaging experiments, making high-resolution metabolic imaging possible. Copyright © 2014 Wiley Periodicals, Inc.

  17. Artifact free T2{sup *}-weighted imaging at high spatial resolution using segmented EPI sequences

    Energy Technology Data Exchange (ETDEWEB)

    Heiler, Patrick Michael; Schad, Lothar Rudi [Heidelberg Univ., Mannheim (Germany). Computer Assisted Clinical Medicine; Schmitter, Sebastian [German Cancer Research Center, Heidelberg (Germany). Dept. of Medical Physics in Radiology

    2010-07-01

    The aim of this work was the development of novel measurement techniques that acquire high resolution T2{sup *}-weighted datasets in measurement times as short as possible without suffering from noticeable blurring and ghosting artifacts. Therefore, two new measurement techniques were developed that acquire a smoother k-space than generic multi shot echo planar imaging sequences. One is based on the principle of echo train shifting, the other on the reversed gradient method. Simulations and phantom measurements demonstrate that echo train shifting works properly and reduces artifacts in multi shot echo planar imaging. For maximum SNR-efficiency this technique was further improved by adding a second contrast. Both contrasts can be acquired within a prolongation in measurement time by a factor of 1.5, leading to an SNR increase by approximately {radical}2. Furthermore it is demonstrated that the reversed gradient method remarkably reduces artifacts caused by a discontinuous k-space weighting. Assuming sequence parameters as feasible for fMRI experiments, artifact free T2{sup *}-weighted images with a matrix size of 256 x 256 leading to an in-plane resolution in the submillimeter range can be obtained in about 2 s per slice. (orig.)

  18. Artifact free T2*-weighted imaging at high spatial resolution using segmented EPI sequences

    International Nuclear Information System (INIS)

    Heiler, Patrick Michael; Schad, Lothar Rudi; Schmitter, Sebastian

    2010-01-01

    The aim of this work was the development of novel measurement techniques that acquire high resolution T2 * -weighted datasets in measurement times as short as possible without suffering from noticeable blurring and ghosting artifacts. Therefore, two new measurement techniques were developed that acquire a smoother k-space than generic multi shot echo planar imaging sequences. One is based on the principle of echo train shifting, the other on the reversed gradient method. Simulations and phantom measurements demonstrate that echo train shifting works properly and reduces artifacts in multi shot echo planar imaging. For maximum SNR-efficiency this technique was further improved by adding a second contrast. Both contrasts can be acquired within a prolongation in measurement time by a factor of 1.5, leading to an SNR increase by approximately √2. Furthermore it is demonstrated that the reversed gradient method remarkably reduces artifacts caused by a discontinuous k-space weighting. Assuming sequence parameters as feasible for fMRI experiments, artifact free T2 * -weighted images with a matrix size of 256 x 256 leading to an in-plane resolution in the submillimeter range can be obtained in about 2 s per slice. (orig.)

  19. Functional MRI studies of human vision on a clinical imager

    International Nuclear Information System (INIS)

    George, J.S.; Lewine, J.D.; Aine, C.J.; van Hulsteyn, D.; Wood, C.C.; Sanders, J.; Maclin, E.; Belliveau, J.W.; Caprihan, A.

    1992-01-01

    During the past decade, Magnetic Resonance Imaging (MRI) has become the method of choice for imaging the anatomy of the human brain. Recently, Belliveau and colleagues have reported the use of echo planar magnetic resonance imaging (EPI) to image patterns of neural activity. Here, we report functional MR imaging in response to visual stimulation without the use of contrast agents, and without the extensive hardware modifications required for EPI. Regions of activity were observed near the expected locations of V1, V2 and possibly V3 and another active region was observed near the parietal-occipital sulcus on the superior surface of the cerebrum. These locations are consistent with sources observed in neuromagnetic studies of the human visual response

  20. Functional imaging of the sensorimotor cortex using an ultra-fast MR imaging method

    International Nuclear Information System (INIS)

    Tsunoda, Akira; Nakajima, Yasoichi; Sato, Kiyoshi; Katayama, Jin; Machida, Yoshio; Nozaki, Seiji; Makita, Jun-ichi.

    1996-01-01

    The aim of this study was to assess changes in brain activity during a motor task and variable sensory stimulation using echo planar imaging, which represents the fastest clinically useful imaging technique available. The subjects of this study were 11 healthy volunteers, 4 males and 11 females, with an average of 26.4 years. The subjects were instructed to tap the fingers of one hand as the motor task. Compressed air was applied 5 times a second as 'simple' sensory stimulation. Simple figures were drawn on the subjects palm as 'complex' sensory stimulation. In all cases, functional imaging was performed by T 2 * -weighted echo planar imaging (TE=53 msec, TR=3000 msec, flip angle=90 degrees, matrix 64 x 64, FOV=205 mm, slice thickness=8 mm) alternately at rest and during the task (intervals: 30 sec). A total of 60 images was collected in 3 minutes. Images obtained by subtracting images at rest and during the task were analyzed. Almost all subjects showed a transient signal increase in the contralateral paracentral region during simple sensory stimulation. Continuous signal increases in the contra- and/or ipsi-lateral para-central region were observed durirg complex sensory stimulation. Some exhibited signal increases in the parietal or frontal association cortex, but they disappeared when subject's attention was distracted during stimulation. All subjects displayed signal increases in the contralateral para-central region during the motor task. Some of them exhibited signal increases in the medial frontal area (supplementary motor area) and ipsilateral para-central region. These results suggest that the signal increases of functional MRI reflect not only simple reactions to stimulation but higher cerebral function as well. (J.P.N.)

  1. Parallel magnetic resonance imaging

    International Nuclear Information System (INIS)

    Larkman, David J; Nunes, Rita G

    2007-01-01

    Parallel imaging has been the single biggest innovation in magnetic resonance imaging in the last decade. The use of multiple receiver coils to augment the time consuming Fourier encoding has reduced acquisition times significantly. This increase in speed comes at a time when other approaches to acquisition time reduction were reaching engineering and human limits. A brief summary of spatial encoding in MRI is followed by an introduction to the problem parallel imaging is designed to solve. There are a large number of parallel reconstruction algorithms; this article reviews a cross-section, SENSE, SMASH, g-SMASH and GRAPPA, selected to demonstrate the different approaches. Theoretical (the g-factor) and practical (coil design) limits to acquisition speed are reviewed. The practical implementation of parallel imaging is also discussed, in particular coil calibration. How to recognize potential failure modes and their associated artefacts are shown. Well-established applications including angiography, cardiac imaging and applications using echo planar imaging are reviewed and we discuss what makes a good application for parallel imaging. Finally, active research areas where parallel imaging is being used to improve data quality by repairing artefacted images are also reviewed. (invited topical review)

  2. Perfusion-weighted MR imaging of uterine leiomyoma

    Energy Technology Data Exchange (ETDEWEB)

    Takase, Hiroyasu; Munechika, Hirotsugu [Showa Univ., Tokyo (Japan). School of Medicine

    2001-06-01

    Serial images of uterine leiomyoma in gradient-echo, echo-planar, magnetic resonance imaging were taken to draw a {delta}R2{sup *} curve after intravenous bolus injection of Gd-DTPA. The {delta}R2{sup *} integral was calculated from a {delta}R2{sup *} curve to have relative perfusion of uterine leiomyoma. We then, evaluated the amount of perfusion correlated with MR findings, size and number of leiomyoma or the clinical symptoms and established that perfusion was correlated positively with the findings of T2 weighted images and clinical symptoms but not with other MR findings or size and number of leiomyoma. In conclusion, we presumed that the clinical symptoms could be reduced by decreasing of an amount of perfusion of uterine leiomyoma in some means. However, it remained uncertain why severe clinical symptoms were associated with a high amount of perfusion in uterine leiomyomas. (author)

  3. Single-shot pectoral plane (PECs I and PECs II) blocks versus continuous local anaesthetic infusion analgesia or both after non-ambulatory breast-cancer surgery: a prospective, randomised, double-blind trial.

    Science.gov (United States)

    O'Scanaill, P; Keane, S; Wall, V; Flood, G; Buggy, D J

    2018-04-01

    Pectoral plane blocks (PECs) are increasingly used in analgesia for patients undergoing breast surgery, and were recently found to be at least equivalent to single-shot paravertebral anaesthesia. However, there are no data comparing PECs with the popular practice of continuous local anaesthetic wound infusion (LA infusion) analgesia for breast surgery. Therefore, we compared the efficacy and safety of PECs blocks with LA infusion, or a combination of both in patients undergoing non-ambulatory breast-cancer surgery. This single-centre, prospective, randomised, double-blind trial analysed 45 women to receive either PECs blocks [levobupivacaine 0.25%, 10 ml PECs I and levobupivacaine 0.25%, 20 ml PECs II (PECs group); LA infusion catheter (levobupivacaine 0.1% at 10 ml h -1 for 24 h (LA infusion group); or both (PECs and LA infusion)]. The primary outcome measure was area under the curve of the pain verbal rating score whilst moving vs time (AUC) over 24 h. Secondary outcomes included total opioid consumption at 24 h. AUC moving was mean (SD) 71 (34) mm h -1 vs 58 (41) vs 23 (20) in PECs, LA infusion, and both, respectively; P=0.002. AUC at rest was also significantly lower in patients receiving both. The total 24 h opioid consumption [median (25-75%)] was 14 mg (9-26) vs 11 (8-24) vs 9 (5-11); P=0.4. No adverse events were observed. The combination of both pre-incisional PECs blocks and postoperative LA infusion provides better analgesia over 24 h than either technique alone after non-ambulatory breast-cancer surgery. NCT 03024697. Copyright © 2018 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.

  4. Assmentment of myocardial perfusion by magnetic resonance imaging: on the way to clinical application

    International Nuclear Information System (INIS)

    Fischer, S.E.; Lorenz, C.H.

    1997-01-01

    Magnetic resonance imaging detects the flow of contrast - enhanced blood and even allows the quantitative assessment of myocardial perfusion. The clinical application of this method is being held back by the difficulties in image evaluation and the limitation of standard techniques to the acquisition of a single slice per heart beat cycle. Recent developments in scanner hardware as well as in image acquisition techniques open up the possibility of assessing myocardial perfusion over the entire heart with a spatial resolution in the range of 2 mm. As an example of such a new scanning strategy, a segmented gradient-echo recalled echo planar imaging sequence with preceding saturation is discussed and results in a patient with an infarction are presented. The clinical use of perfusion assessment covering the entire heart for the diagnosis of coronary artery disease is enhanced by the flexibility of magnetic resonance imaging for the assessment of functional cardiac parameters. (orig.) [de

  5. Cardiac and vascular imaging with snapshot FLASH MR imaging

    International Nuclear Information System (INIS)

    Matthaei, D.; Haase, A.; Norris, D.; Leibfritz, D.; Henrich, D.; Duhmke, E.

    1989-01-01

    Acceleration of fast low-angle-shot (FLASH) MR imaging to about 200 msec measuring time on dedicated MR systems is called snapshot FLASH MR imaging. It snaps real-time series of MR images of the MR relaxation and of physiologic motions with nearly absent motion and susceptibility artifacts. Results in animals (4.7T) and human volunteers (2.0T) show plain vascular and cardiac snapshot FLASH MR images obtained as single shot, triggered reconstructed motion, or real-time films. The reduction of artifacts and the high resolution (triggered, three-dimensional moving heart images are possible) result in favorable applications in myocardial and great vascular disease

  6. Multichannel far-infrared phase imaging for fusion plasmas

    International Nuclear Information System (INIS)

    Young, P.E.; Neikirk, D.P.; Tong, P.P.; Rutledge, D.B.; Luhmann, N.C. Jr.

    1985-01-01

    A 20-channel far-infrared imaging interferometer system has been used to obtain single-shot density profiles in the UCLA Microtor tokamak. This system differs from conventional multichannel interferometers in that the phase distribution produced by the plasma is imaged onto a single, monolithic, integrated microbolometer linear detector array and provides significantly more channels than previous far-infrared interferometers. The system has been demonstrated to provide diffraction-limited phase images of dielectric targets

  7. Role of diffusion-weighted magnetic resonance imaging in the diagnosis of extrahepatic cholangiocarcinoma

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    AIM: To determine the clinical value of diffusion-weight- ed imaging (DWI) for the diagnosis of extrahepatic cholangiocarcinoma (EHCC) by comparing the diagnostic sensitivity of DWI and magnetic resonance cholan-giopancreatography (MRCP). METHODS: Magnetic resonance imaging examination was performed in 56 patients with suspected EHCC. T1- weighted imaging, T2-weighted imaging, MRCP and DWI sequence, DWI using single-shot spin-echo echoplanar imaging sequence with different b values (100, 300, 500, 800 and 1...

  8. Post-operative analgesia following total knee arthroplasty: comparison of low-dose intrathecal morphine and single-shot ultrasound-guided femoral nerve block: a randomized, single blinded, controlled study.

    Science.gov (United States)

    Frassanito, L; Vergari, A; Zanghi, F; Messina, A; Bitondo, M; Antonelli, M

    2010-07-01

    .7 mg vs 13.6 mg. However, the difference in the opiate consumption was not statistically different (p value = 0.06). Thirteen patients in ITM group experienced itching, only 5 in FNB group. We did not find any difference in the two treatment groups in the use of antiemetic and antipruritic medication. No cases of respiratory depression was recorded. Our results show that low dose of intrathecal morphine may be safe and more efficient than single-shot femoral nerve block for post-operative analgesia after total knee arthroplasty.

  9. Increased self-diffusion of brain water in hydrocephalus measured by MR imaging

    DEFF Research Database (Denmark)

    Gideon, P; Thomsen, C; Gjerris, F

    1994-01-01

    We used MR imaging to measure the apparent brain water self-diffusion in 5 patients with normal pressure hydrocephalus (NPH), in 2 patients with high pressure hydrocephalus (HPH), and in 8 age-matched controls. In all patients with NPH significant elevations of the apparent diffusion coefficients...... white matter, and in one patient reexamined one year after surgery, ADCs were unchanged in nearly all brain regions. The increased ADC values in hydrocephalus patients may be caused by factors such as changes in myelin-associated bound water, increased Virchow-Robin spaces, and increased extracellular...... brain water fraction. For further studies of brain water diffusion in hydrocephalus patients, echo-planar imaging techniques with imaging times of a few seconds may be valuable....

  10. 7 Tesla compatible in-bore display for functional magnetic resonance imaging.

    Science.gov (United States)

    Groebner, Jens; Berger, Moritz Cornelius; Umathum, Reiner; Bock, Michael; Rauschenberg, Jaane

    2013-08-01

    A liquid crystal display was modified for use inside a 7 T MR magnet. SNR measurements were performed using different imaging sequences with the monitor absent, present, or activated. fMRI with a volunteer was conducted using a visual stimulus. SNR was reduced by 3.7%/7.9% in echo planar/fast-spin echo images when the monitor was on which can be explained by the limited shielding of the coated front window (40 dB). In the fMRI experiments, activated regions in the visual cortex were clearly visible. The monitor provided excellent resolution at minor SNR reduction in EPI images, and is thus suitable for fMRI at ultra-high field.

  11. The role of isotropic diffusion MRI in children under 2 years of age

    International Nuclear Information System (INIS)

    Gelal, F.M.; Grant, P.E.; Fischbein, N.J.; Henry, R.G.; Vigneron, D.B.; Barkovich, A.J.

    2001-01-01

    Our objective was to determine the contribution of diffusion MR imaging to standard MR imaging in the neuroradiological evaluation of children less than 2 years of age. Echo-planar diffusion MR imaging was added to standard MR exams in 75 consecutive patients under the age of 2 years. Single-shot echo-planar spin-echo T2 weighted images (EPSE-T2) were acquired. Isotropic diffusion-weighted images (DWI), attenuation coefficient maps (ACM), and apparent diffusion coefficient (ADC) maps were calculated offline from images obtained with diffusion gradients (b=1000 s/mm 2 ) in three orthogonal directions. Two neuroradiologists determined if EPSE-T2, DWI, or ACM contributed new information to spin-echo proton density (SE PD) and T2 studies. In 15 of 18 abnormalities detected in 8 patients with symptoms less than 1 week in duration, DWI and/or ACM added information to SE PD and T2. Diffusion sequences detected five new lesions, showed six lesions with greater conspicuity, and identified four lesions with different diffusion character. In patients with symptoms of more than 7 days duration, diffusion studies added no information. Isotropic diffusion MR contributed to lesion detection and characterization in infants when symptoms were less than 1 week in duration. Diffusion MR is useful in patients with leukodystrophies, metabolic disorders, and patients with acute ischemic lesions. (orig.)

  12. Efficacy of triplet regimen antiemetic therapy for chemotherapy-induced nausea and vomiting (CINV) in bone and soft tissue sarcoma patients receiving highly emetogenic chemotherapy, and an efficacy comparison of single-shot palonosetron and consecutive-day granisetron for CINV in a randomized, single-blinded crossover study

    International Nuclear Information System (INIS)

    Kimura, Hiroaki; Yamamoto, Norio; Shirai, Toshiharu; Nishida, Hideji; Hayashi, Katsuhiro; Tanzawa, Yoshikazu; Takeuchi, Akihiko; Igarashi, Kentaro; Inatani, Hiroyuki; Shimozaki, Shingo; Kato, Takashi; Aoki, Yu; Higuchi, Takashi; Tsuchiya, Hiroyuki

    2015-01-01

    The first aim of this study was to evaluate combination antiemetic therapy consisting of 5-HT 3 receptor antagonists, neurokinin-1 receptor antagonists (NK-1RAs), and dexamethasone for multiple high emetogenic risk (HER) anticancer agents in bone and soft tissue sarcoma. The second aim was to compare the effectiveness of single-shot palonosetron and consecutive-day granisetron in a randomized, single-blinded crossover study. A single randomization method was used to assign eligible patients to the palonosetron or granisetron arm. Patients in the palonosetron arm received a palonosetron regimen during the first and third chemotherapy courses and a granisetron regimen during the second and fourth courses. All patients received NK-1RA and dexamethasone. Patients receiving the palonosetron regimen were administered 0.75 mg palonosetron on day 1, and patients receiving the granisetron regimen were administered 3 mg granisetron twice daily on days 1 through 5. All 24 patients in this study received at least 4 chemotherapy courses. A total of 96 courses of antiemetic therapy were evaluated. Overall, the complete response CR rate (no emetic episodes and no rescue medication use) was 34%, while the total control rate (a CR plus no nausea) was 7%. No significant differences were observed between single-shot palonosetron and consecutive-day granisetron. Antiemetic therapy with a 3-drug combination was not sufficient to control chemotherapy-induced nausea and vomiting (CINV) during chemotherapy with multiple HER agents for bone and soft tissue sarcoma. This study also demonstrated that consecutive-day granisetron was not inferior to single-shot palonosetron for treating CINV

  13. Efficacy of triplet regimen antiemetic therapy for chemotherapy-induced nausea and vomiting (CINV) in bone and soft tissue sarcoma patients receiving highly emetogenic chemotherapy, and an efficacy comparison of single-shot palonosetron and consecutive-day granisetron for CINV in a randomized, single-blinded crossover study.

    Science.gov (United States)

    Kimura, Hiroaki; Yamamoto, Norio; Shirai, Toshiharu; Nishida, Hideji; Hayashi, Katsuhiro; Tanzawa, Yoshikazu; Takeuchi, Akihiko; Igarashi, Kentaro; Inatani, Hiroyuki; Shimozaki, Shingo; Kato, Takashi; Aoki, Yu; Higuchi, Takashi; Tsuchiya, Hiroyuki

    2015-03-01

    The first aim of this study was to evaluate combination antiemetic therapy consisting of 5-HT3 receptor antagonists, neurokinin-1 receptor antagonists (NK-1RAs), and dexamethasone for multiple high emetogenic risk (HER) anticancer agents in bone and soft tissue sarcoma. The second aim was to compare the effectiveness of single-shot palonosetron and consecutive-day granisetron in a randomized, single-blinded crossover study. A single randomization method was used to assign eligible patients to the palonosetron or granisetron arm. Patients in the palonosetron arm received a palonosetron regimen during the first and third chemotherapy courses and a granisetron regimen during the second and fourth courses. All patients received NK-1RA and dexamethasone. Patients receiving the palonosetron regimen were administered 0.75 mg palonosetron on day 1, and patients receiving the granisetron regimen were administered 3 mg granisetron twice daily on days 1 through 5. All 24 patients in this study received at least 4 chemotherapy courses. A total of 96 courses of antiemetic therapy were evaluated. Overall, the complete response CR rate (no emetic episodes and no rescue medication use) was 34%, while the total control rate (a CR plus no nausea) was 7%. No significant differences were observed between single-shot palonosetron and consecutive-day granisetron. Antiemetic therapy with a 3-drug combination was not sufficient to control chemotherapy-induced nausea and vomiting (CINV) during chemotherapy with multiple HER agents for bone and soft tissue sarcoma. This study also demonstrated that consecutive-day granisetron was not inferior to single-shot palonosetron for treating CINV. © 2014 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  14. Fetal magnetic resonance imaging: indications, technique, anatomical considerations and a review of fetal abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Ertl-Wagner, Birgit [Department of Radiology, Klinikum Grosshadern, University of Munich, Marchioninistrasse 15, 81377 Munich (Germany); Present address: Institute of Clinical Radiology, Klinikum Grosshadern, University of Munich, Marchioninistrasse 15, 81377 Munich (Germany); Lienemann, Andreas; Reiser, Maximilian F. [Department of Radiology, Klinikum Grosshadern, University of Munich, Marchioninistrasse 15, 81377 Munich (Germany); Strauss, Alexander [Department of Obstetrics and Gynecology, Klinikum Grosshadern, University of Munich, Marchioninistrasse 15, 81377 Munich (Germany)

    2002-08-01

    Fetal MR imaging often poses a diagnostic challenge for the radiologist. Both fetal anatomy and pathology differ decidedly from pediatric and adult MR imaging. While ultrasound remains the method of choice for screening examinations of the fetus, MR imaging is playing an increasingly important role in the detection and classification of malformations not diagnosable by ultrasonography alone. Recently, advances in fast single-shot MR sequences have allowed high-resolution, high-quality imaging of the moving fetus. Preferable sequences to be applied are a true fast imaging steady precession (true-FISP) or a half-Fourier acquired single-shot turbo spin-echo (HASTE) sequence. Premedication is generally no longer required. In all fetal MR imaging, every aspect of fetal anatomy has to be scrutinized. Subsequently, any abnormalities need to be described and classified. A close collaboration with the referring obstetrician is of paramount importance. (orig.)

  15. Magnetic Resonance Imaging Including Magnetic Resonance Cholangiopancreatography for Tumor Localization and Therapy Planning in Malignant Hilar Obstructions

    International Nuclear Information System (INIS)

    Haenninen, E.L.

    2005-01-01

    PURPOSE: To assess image quality and overall accuracy of magnetic resonance imaging (MRI), including two magnetic cholangiopancreatography (MRCP) techniques, for the diagnostics and preoperative work-up of malignant hilar obstructions. MATERIAL AND METHODS: Thirty-one patients with malignant hilar obstructions (hilar cholangiocarcinoma, n=30; hepatocellular carcinoma, n=1) received MRCP by two techniques (single-shot thick-slab and multisection thin-slice MRCP) and unenhanced and contrast material-enhanced MRI. MR assessment included the evaluation of image quality and visualization of bile ducts (5-point scale), and the classification of tumor status. MR results were subsequently correlated with the results from surgery and pathology. RESULTS: The maximum intensity projections of multisection thin-slice MRCP had significantly more artifacts compared to MRCP in the single-shot thick-slab technique, and overall image quality of single-shot thick-slab MRCP was rated significantly superior compared to multisection thin-slice MRCP (4.4 ± 0.7 and 4.1 ± 0.9, respectively). Moreover, ductal visualization of different parts of the biliary system was rated superior with single-shot thick-slab MRCP. In contrast, the original data from multisection thin slice MRCP facilitated visualization of periductal lesions and adjacent structures. Overall MR accuracy for the assessment of tumor status, periductal infiltration, and lymph node metastases was 90%, 87%, and 66%, respectively. CONCLUSION: For evaluation of malignant hilar obstructions, MRCP by the single-shot thick-slab technique had superior image quality and fewer artifacts; in contrast, besides sole biliary visualization, multisection MRCP depicted complementary adjacent parenchymal and periductal structures. We therefore recommend MRI, with a combination of both MRCP techniques, for the diagnostic work-up and therapy planning of malignant hilar obstructions

  16. Free-breathing motion-corrected late-gadolinium-enhancement imaging improves image quality in children

    International Nuclear Information System (INIS)

    Olivieri, Laura; O'Brien, Kendall J.; Cross, Russell; Xue, Hui; Kellman, Peter; Hansen, Michael S.

    2016-01-01

    The value of late-gadolinium-enhancement (LGE) imaging in the diagnosis and management of pediatric and congenital heart disease is clear; however current acquisition techniques are susceptible to error and artifacts when performed in children because of children's higher heart rates, higher prevalence of sinus arrhythmia, and inability to breath-hold. Commonly used techniques in pediatric LGE imaging include breath-held segmented FLASH (segFLASH) and steady-state free precession-based (segSSFP) imaging. More recently, single-shot SSFP techniques with respiratory motion-corrected averaging have emerged. This study tested and compared single-shot free-breathing LGE techniques with standard segmented breath-held techniques in children undergoing LGE imaging. Thirty-two consecutive children underwent clinically indicated late-enhancement imaging using intravenous gadobutrol 0.15 mmol/kg. Breath-held segSSFP, breath-held segFLASH, and free-breathing single-shot SSFP LGE sequences were performed in consecutive series in each child. Two blinded reviewers evaluated the quality of the images and rated them on a scale of 1-5 (1 = poor, 5 = superior) based on blood pool-myocardial definition, presence of cardiac motion, presence of respiratory motion artifacts, and image acquisition artifact. We used analysis of variance (ANOVA) to compare groups. Patients ranged in age from 9 months to 18 years, with a mean +/- standard deviation (SD) of 13.3 +/- 4.8 years. R-R interval at the time of acquisition ranged 366-1,265 milliseconds (ms) (47-164 beats per minute [bpm]), mean +/- SD of 843+/-231 ms (72+/-21 bpm). Mean +/- SD quality ratings for long-axis imaging for segFLASH, segSSFP and single-shot SSFP were 3.1+/-0.9, 3.4+/-0.9 and 4.0+/-0.9, respectively (P < 0.01 by ANOVA). Mean +/- SD quality ratings for short-axis imaging for segFLASH, segSSFP and single-shot SSFP were 3.4+/-1, 3.8+/-0.9 and 4.3+/-0.7, respectively (P < 0.01 by ANOVA). Single-shot late

  17. Free-breathing motion-corrected late-gadolinium-enhancement imaging improves image quality in children

    Energy Technology Data Exchange (ETDEWEB)

    Olivieri, Laura; O' Brien, Kendall J. [Children' s National Health System, Division of Cardiology, Washington, DC (United States); National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD (United States); Cross, Russell [Children' s National Health System, Division of Cardiology, Washington, DC (United States); Xue, Hui; Kellman, Peter; Hansen, Michael S. [National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD (United States)

    2016-06-15

    The value of late-gadolinium-enhancement (LGE) imaging in the diagnosis and management of pediatric and congenital heart disease is clear; however current acquisition techniques are susceptible to error and artifacts when performed in children because of children's higher heart rates, higher prevalence of sinus arrhythmia, and inability to breath-hold. Commonly used techniques in pediatric LGE imaging include breath-held segmented FLASH (segFLASH) and steady-state free precession-based (segSSFP) imaging. More recently, single-shot SSFP techniques with respiratory motion-corrected averaging have emerged. This study tested and compared single-shot free-breathing LGE techniques with standard segmented breath-held techniques in children undergoing LGE imaging. Thirty-two consecutive children underwent clinically indicated late-enhancement imaging using intravenous gadobutrol 0.15 mmol/kg. Breath-held segSSFP, breath-held segFLASH, and free-breathing single-shot SSFP LGE sequences were performed in consecutive series in each child. Two blinded reviewers evaluated the quality of the images and rated them on a scale of 1-5 (1 = poor, 5 = superior) based on blood pool-myocardial definition, presence of cardiac motion, presence of respiratory motion artifacts, and image acquisition artifact. We used analysis of variance (ANOVA) to compare groups. Patients ranged in age from 9 months to 18 years, with a mean +/- standard deviation (SD) of 13.3 +/- 4.8 years. R-R interval at the time of acquisition ranged 366-1,265 milliseconds (ms) (47-164 beats per minute [bpm]), mean +/- SD of 843+/-231 ms (72+/-21 bpm). Mean +/- SD quality ratings for long-axis imaging for segFLASH, segSSFP and single-shot SSFP were 3.1+/-0.9, 3.4+/-0.9 and 4.0+/-0.9, respectively (P < 0.01 by ANOVA). Mean +/- SD quality ratings for short-axis imaging for segFLASH, segSSFP and single-shot SSFP were 3.4+/-1, 3.8+/-0.9 and 4.3+/-0.7, respectively (P < 0.01 by ANOVA). Single-shot late

  18. Functional imaging of cerebral cortex activation with a 1.5-T MR imaging system

    International Nuclear Information System (INIS)

    Kim, Jae Hyoung; Chang, Sun Ae; Ha, Choong Kun; Kim, Eun Sang; Kim, Hyung Jin; Chung, Sung Hoon

    1995-01-01

    Most of recent MR imagings of cerebral cortex activation have been performed by using high field magnet above 2-T or echo-planar imaging technique. We report our experience on imaging of cerebral cortex activation with a widely available standard 1.5-T MR. Series of gradient-echo images (TR/TE/flip angle: 80/60/40 .deg. 64 x 128 matrix) were acquired alternatively during the periods of rest and task in five normal volunteers. Finger movement (n = 10;5 right, 5 left) and flashing photic stimulation (n 1) were used as a motor task and a visual task to activate the motor cortex and visual cortex, respectively. Activation images were obtained by subtracting sum of rest images from that of task images. Changes of signal intensity were analyzed over the periods of rest and task. Activation images were obtained in all cases. Changes of signal intensity between rest and task periods were 6.5-14.6%(mean, 10.5%) in the motor cortex and 4.2% in the visual cortex. Functional imaging of cerebral cortex activation could be performed with a widely available 1.5-T MR. Widespread applications of this technique to basic and clinical neuroscience are expected

  19. Functional imaging of cerebral cortex activation with a 1.5-T MR imaging system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Hyoung; Chang, Sun Ae; Ha, Choong Kun; Kim, Eun Sang; Kim, Hyung Jin; Chung, Sung Hoon [Gyeongsang National University, College of Medicine, Jeongju (Korea, Republic of)

    1995-07-15

    Most of recent MR imagings of cerebral cortex activation have been performed by using high field magnet above 2-T or echo-planar imaging technique. We report our experience on imaging of cerebral cortex activation with a widely available standard 1.5-T MR. Series of gradient-echo images (TR/TE/flip angle: 80/60/40 .deg. 64 x 128 matrix) were acquired alternatively during the periods of rest and task in five normal volunteers. Finger movement (n = 10;5 right, 5 left) and flashing photic stimulation (n 1) were used as a motor task and a visual task to activate the motor cortex and visual cortex, respectively. Activation images were obtained by subtracting sum of rest images from that of task images. Changes of signal intensity were analyzed over the periods of rest and task. Activation images were obtained in all cases. Changes of signal intensity between rest and task periods were 6.5-14.6%(mean, 10.5%) in the motor cortex and 4.2% in the visual cortex. Functional imaging of cerebral cortex activation could be performed with a widely available 1.5-T MR. Widespread applications of this technique to basic and clinical neuroscience are expected.

  20. Comparison of apparent diffusion coefficients (ADCs) between two-point and multi-point analyses using high-B-value diffusion MR imaging

    International Nuclear Information System (INIS)

    Kubo, Hitoshi; Maeda, Masayuki; Araki, Akinobu

    2001-01-01

    We evaluated the accuracy of calculating apparent diffusion coefficients (ADCs) using high-B-value diffusion images. Echo planar diffusion-weighted MR images were obtained at 1.5 tesla in five standard locations in six subjects using gradient strengths corresponding to B values from 0 to 3000 s/mm 2 . Estimation of ADCs was made using two methods: a nonlinear regression model using measurements from a full set of B values (multi-point method) and linear estimation using B values of 0 and max only (two-point method). A high correlation between the two methods was noted (r=0.99), and the mean percentage differences were -0.53% and 0.53% in phantom and human brain, respectively. These results suggest there is little error in estimating ADCs calculated by the two-point technique using high-B-value diffusion MR images. (author)

  1. The value of diffusion-weighted imaging for prediction of lasting deficit in acute stroke: an analysis of 134 patients with acute neurologic deficits

    International Nuclear Information System (INIS)

    Wiener, J.I.; King, J.T. Jr.; Moore, J.R.; Lewin, J.S.

    2001-01-01

    Acute stroke is one of the three major causes of death and disability in the United States. Now that new, and possibly effective therapy is becoming available, accurate, rapid diagnosis is important to provide timely treatment, while avoiding the risk of complications from unnecessary intervention. Our objective was to test the hypothesis that use of echo-planar (EPI) diffusion-weighted imaging (DWI) is more accurate than conventional T 2 weighted MRI in predicting progression to stroke in patients with acute ischemic neurologic deficits. We studied 134 patients presenting with acute neurologic deficits to a community hospital emergency room with both conventional MRI and DWI within 72 h of the onset of the acute deficit. We found DWI significantly more sensitive to permanent neurologic deficit at discharge (sensitivity 0.81) than conventional MRI (sensitivity 0.41). When available, DWI should be considered for routine use in patients being imaged for acute stroke. (orig.)

  2. Incidental ferumoxytol artifacts in clinical brain MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Bowser, Bruce A.; Campeau, Norbert G.; Carr, Carrie M.; Diehn, Felix E.; McDonald, Jennifer S.; Miller, Gary M.; Kaufmann, Timothy J. [Mayo Clinic, Department of Radiology, Rochester, MN (United States)

    2016-11-15

    Ferumoxytol (Feraheme) is a parenteral therapy approved for treatment of iron deficiency anemia. The product insert for ferumoxytol states that it may affect the diagnostic ability of MRI for up to 3 months. However, the expected effects may not be commonly recognized among clinical neuroradiologists. Our purpose is to describe the artifacts we have seen at our institution during routine clinical practice. We reviewed the patients at our institution that had brain MRI performed within 90 days of receiving intravenous ferumoxytol. The imaging was reviewed for specific findings, including diffusion-weighted imaging vascular susceptibility artifact, gradient-echo echo-planar T2*-weighted vascular susceptibility artifact, SWI/SWAN vascular susceptibility artifact, hypointense vascular signal on T2-weighted images, pre-gadolinium contrast vascular enhancement on magnetization-prepared rapid acquisition gradient echo (MPRAGE) imaging, and effects on post-gadolinium contrast T1 imaging. Multiple artifacts were observed in patients having a brain MRI within 3 days of receiving intravenous ferumoxytol. These included susceptibility artifact on DWI, GRE, and SWAN/SWI imaging, pre-gadolinium contrast increased vascular signal on MPRAGE imaging, and decreased expected enhancement on post-gadolinium contrast T1-weighted imaging. Ferumoxytol can create imaging artifacts which complicate clinical interpretation when brain MRI is performed within 3 days of administration. Recognition of the constellation of artifacts produced by ferumoxytol is important in order to obviate additional unnecessary examinations and mitigate errors in interpretation. (orig.)

  3. Feasibility and resolution limits of opto-magnetic imaging of neural network activity in brain slices using color centers in diamond

    DEFF Research Database (Denmark)

    Karadas, Mürsel; Wojciechowski, Adam M.; Huck, Alexander

    2018-01-01

    We suggest a novel approach for wide-field imaging of the neural network dynamics of brain slices that uses highly sensitivity magnetometry based on nitrogen-vacancy (NV) centers in diamond. Invitro recordings in brain slices is a proven method for the characterization of electrical neural activi...... cell. Our results suggest that imaging of slice activity will be possible with the upcoming generation of NV magnetic field sensors, while single-shot imaging of planar cell activity remains challenging....

  4. Restoring susceptibility induced MRI signal loss in rat brain at 9.4 T: A step towards whole brain functional connectivity imaging.

    Directory of Open Access Journals (Sweden)

    Rupeng Li

    Full Text Available The aural cavity magnetic susceptibility artifact leads to significant echo planar imaging (EPI signal dropout in rat deep brain that limits acquisition of functional connectivity fcMRI data. In this study, we provide a method that recovers much of the EPI signal in deep brain. Needle puncture introduction of a liquid-phase fluorocarbon into the middle ear allows acquisition of rat fcMRI data without signal dropout. We demonstrate that with seeds chosen from previously unavailable areas, including the amygdala and the insular cortex, we are able to acquire large scale networks, including the limbic system. This tool allows EPI-based neuroscience and pharmaceutical research in rat brain using fcMRI that was previously not feasible.

  5. Exploring brain function with magnetic resonance imaging

    International Nuclear Information System (INIS)

    Di Salle, F.; Formisano, E.; Linden, D.E.J.; Goebel, R.; Bonavita, S.; Pepino, A.; Smaltino, F.; Tedeschi, G.

    1999-01-01

    Since its invention in the early 1990s, functional magnetic resonance imaging (fMRI) has rapidly assumed a leading role among the techniques used to localize brain activity. The spatial and temporal resolution provided by state-of-the-art MR technology and its non-invasive character, which allows multiple studies of the same subject, are some of the main advantages of fMRI over the other functional neuroimaging modalities that are based on changes in blood flow and cortical metabolism. This paper describes the basic principles and methodology of fMRI and some aspects of its application to functional activation studies. Attention is focused on the physiology of the blood oxygenation level-dependent (BOLD) contrast mechanism and on the acquisition of functional time-series with echo planar imaging (EPI). We also provide an introduction to the current strategies for the correction of signal artefacts and other image processing techniques. In order to convey an idea of the numerous applications of fMRI, we will review some of the recent results in the fields of cognitive and sensorimotor psychology and physiology

  6. Exploring brain function with magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Di Salle, F.; Formisano, E.; Linden, D.E.J.; Goebel, R.; Bonavita, S.; Pepino, A.; Smaltino, F.; Tedeschi, G

    1999-05-01

    Since its invention in the early 1990s, functional magnetic resonance imaging (fMRI) has rapidly assumed a leading role among the techniques used to localize brain activity. The spatial and temporal resolution provided by state-of-the-art MR technology and its non-invasive character, which allows multiple studies of the same subject, are some of the main advantages of fMRI over the other functional neuroimaging modalities that are based on changes in blood flow and cortical metabolism. This paper describes the basic principles and methodology of fMRI and some aspects of its application to functional activation studies. Attention is focused on the physiology of the blood oxygenation level-dependent (BOLD) contrast mechanism and on the acquisition of functional time-series with echo planar imaging (EPI). We also provide an introduction to the current strategies for the correction of signal artefacts and other image processing techniques. In order to convey an idea of the numerous applications of fMRI, we will review some of the recent results in the fields of cognitive and sensorimotor psychology and physiology.

  7. Computational multispectral video imaging [Invited].

    Science.gov (United States)

    Wang, Peng; Menon, Rajesh

    2018-01-01

    Multispectral imagers reveal information unperceivable to humans and conventional cameras. Here, we demonstrate a compact single-shot multispectral video-imaging camera by placing a micro-structured diffractive filter in close proximity to the image sensor. The diffractive filter converts spectral information to a spatial code on the sensor pixels. Following a calibration step, this code can be inverted via regularization-based linear algebra to compute the multispectral image. We experimentally demonstrated spectral resolution of 9.6 nm within the visible band (430-718 nm). We further show that the spatial resolution is enhanced by over 30% compared with the case without the diffractive filter. We also demonstrate Vis-IR imaging with the same sensor. Because no absorptive color filters are utilized, sensitivity is preserved as well. Finally, the diffractive filters can be easily manufactured using optical lithography and replication techniques.

  8. Thin-Section Diffusion-Weighted Magnetic Resonance Imaging of the Brain with Parallel Imaging

    International Nuclear Information System (INIS)

    Oner, A.Y.; Celik, H.; Tali, T.; Akpek, S.; Tokgoz, N.

    2007-01-01

    Background: Thin-section diffusion-weighted imaging (DWI) is known to improve lesion detectability, with long imaging time as a drawback. Parallel imaging (PI) is a technique that takes advantage of spatial sensitivity information inherent in an array of multiple-receiver surface coils to partially replace time-consuming spatial encoding and reduce imaging time. Purpose: To prospectively evaluate a 3-mm-thin-section DWI technique combined with PI by means of qualitative and quantitative measurements. Material and Methods: 30 patients underwent conventional echo-planar (EPI) DWI (5-mm section thickness, 1-mm intersection gap) without parallel imaging, and thin-section EPI-DWI with PI (3-mm section thickness, 0-mm intersection gap) for a b value of 1000 s/mm 2 , with an imaging time of 40 and 80 s, respectively. Signal-to-noise ratio (SNR), relative signal intensity (rSI), and apparent diffusion coefficient (ADC) values were measured over a lesion-free cerebral region on both series by two radiologists. A quality score was assigned for each set of images to assess the image quality. When a brain lesion was present, contrast-to-noise ratio (CNR) and corresponding ADC were also measured. Student t-tests were used for statistical analysis. Results: Mean SNR values of the normal brain were 33.61±4.35 and 32.98±7.19 for conventional and thin-slice DWI (P>0.05), respectively. Relative signal intensities were significantly higher on thin-section DWI (P 0.05). Quality scores and overall lesion CNR were found to be higher in thin-section DWI with parallel imaging. Conclusion: A thin-section technique combined with PI improves rSI, CNR, and image quality without compromising SNR and ADC measurements in an acceptable imaging time. Keywords: Brain; DWI; parallel imaging; thin section

  9. T2 mapping of muscle activity using ultrafast imaging

    International Nuclear Information System (INIS)

    Tawara, Noriyuki; Nitta, Osamu; Kuruma, Hironobu; Niitsu, Mamoru; Itoh, Akiyoshi

    2011-01-01

    Measuring exercise-induced muscle activity is essential in sports medicine. Previous studies proposed measuring transverse relaxation time (T 2 ) using muscle functional magnetic resonance imaging (mfMRI) to map muscle activity. However, mfMRI uses a spin-echo (SE) sequence that requires several minutes for acquisition. We evaluated the feasibility of T 2 mapping of muscle activity using ultrafast imaging, called fast-acquired mfMRI (fast-mfMRI), to reduce image acquisition time. The current method uses 2 pulse sequences, spin-echo echo-planar imaging (SE-EPI) and true fast imaging with steady precession (TrueFISP). SE-EPI images are used to calculate T 2 , and TrueFISP images are used to obtain morphological information. The functional image is produced by subtracting the image of muscle activity obtained using T 2 at rest from that produced after exercise. Final fast-mfMRI images are produced by fusing the functional images with the morphologic images. Ten subjects repeated ankle plantar flexion 200 times. In the fused images, the areas of activated muscle in the fast-mfMRI and SE-EPI images were identical. The geometric location of the fast-mfMRI did not differ between the morphologic and functional images. Morphological and functional information from fast-mfMRI can be applied to the human trunk, which requires limited scan duration. The difference obtained by subtracting T 2 at rest from T 2 after exercise can be used as a functional image of muscle activity. (author)

  10. Controlling cavitation-based image contrast in focused ultrasound histotripsy surgery.

    Science.gov (United States)

    Allen, Steven P; Hall, Timothy L; Cain, Charles A; Hernandez-Garcia, Luis

    2015-01-01

    To develop MRI feedback for cavitation-based, focused ultrasound, tissue erosion surgery (histotripsy), we investigate image contrast generated by transient cavitation events. Changes in GRE image intensity are observed while balanced pairs of field gradients are varied in the presence of an acoustically driven cavitation event. The amplitude of the acoustic pulse and the timing between a cavitation event and the start of these gradient waveforms are also varied. The magnitudes and phases of the cavitation site are compared with those of control images. An echo-planar sequence is used to evaluate histotripsy lesions in ex vivo tissue. Cavitation events in water cause localized attenuation when acoustic pulses exceed a pressure threshold. Attenuation increases with increasing gradient amplitude and gradient lobe separation times and is isotropic with gradient direction. This attenuation also depends upon the relative timing between the cavitation event and the start of the balanced gradients. These factors can be used to control the appearance of attenuation while imaging ex vivo tissue. By controlling the timing between cavitation events and the imaging gradients, MR images can be made alternately sensitive or insensitive to cavitation. During therapy, these images can be used to isolate contrast generated by cavitation. © 2014 Wiley Periodicals, Inc.

  11. Task-related signal decrease on functional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Hara, Yoshie; Nakamura, Mitsugu; Tamaki, Norihiko; Tamura, Shogo; Kitamura, Junji

    2001-01-01

    An atypical pattern of signal change was identified on functional magnetic resonance (fMR) imaging in pathologic patients. Three normal volunteers and 34 patients with pathologic lesions near the primary motor cortex underwent fMR imaging with echo-planar imaging while performing a hand motor task. Signal intensities were evaluated with the z-score method, and the time course and changes of the signal intensity were calculated. Nine of the 34 patients with pathologic lesions displayed a significant task-related signal reduction in motor-related areas. They also presented a conventional task-related signal increase in other motor-related areas. The time courses of the increase and decrease were the inverse of each other. There was no significant difference between rates of signal increase and decrease. Our findings suggest that this atypical signal decrease is clinically significant, and that impaired vascular reactivity and altered oxygen metabolism could contribute to the task-related signal reduction. Brain areas showing such task-related signal decrease should be preserved at surgery. (author)

  12. Preoperative subtyping of meningiomas by perfusion MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Hao [University Medical Center Groningen, University of Groningen (Netherlands); Shanghai Jiaotong University affiliated First People' s Hospital, Department of Radiology, Shanghai (China); Department of Radiology, University of Groningen (Netherlands); Roediger, Lars A.; Oudkerk, Matthijs [University Medical Center Groningen, University of Groningen (Netherlands); Department of Radiology, University of Groningen (Netherlands); Shen, Tianzhen [Fudan University Huashan Hospital, Department of Radiology, Shanghai (China); Miao, Jingtao [Shanghai Jiaotong University affiliated First People' s Hospital, Department of Radiology, Shanghai (China)

    2008-10-15

    This paper aims to evaluate the value of perfusion magnetic resonance (MR) imaging in the preoperative subtyping of meningiomas by analyzing the relative cerebral blood volume (rCBV) of three benign subtypes and anaplastic meningiomas separately. Thirty-seven meningiomas with peritumoral edema (15 meningothelial, ten fibrous, four angiomatous, and eight anaplastic) underwent perfusion MR imaging by using a gradient echo echo-planar sequence. The maximal rCBV (compared with contralateral normal white matter) in both tumoral parenchyma and peritumoral edema of each tumor was measured. The mean rCBVs of each two histological subtypes were compared using one-way analysis of variance and least significant difference tests. A p value less than 0.05 indicated a statistically significant difference. The mean rCBV of meningothelial, fibrous, angiomatous, and anaplastic meningiomas in tumoral parenchyma were 6.93{+-}3.75, 5.61{+-}4.03, 11.86{+-}1.93, and 5.89{+-}3.85, respectively, and in the peritumoral edema 0.87{+-}0.62, 1.38{+-}1.44, 0.87{+-}0.30, and 3.28{+-}1.39, respectively. The mean rCBV in tumoral parenchyma of angiomatous meningiomas and in the peritumoral edema of anaplastic meningiomas were statistically different (p<0.05) from the other types of meningiomas. Perfusion MR imaging can provide useful functional information on meningiomas and help in the preoperative diagnosis of some subtypes of meningiomas. (orig.)

  13. Generalized INverse imaging (GIN): ultrafast fMRI with physiological noise correction.

    Science.gov (United States)

    Boyacioğlu, Rasim; Barth, Markus

    2013-10-01

    An ultrafast functional magnetic resonance imaging (fMRI) technique, called generalized inverse imaging (GIN), is proposed, which combines inverse imaging with a phase constraint-leading to a less underdetermined reconstruction-and physiological noise correction. A single 3D echo planar imaging (EPI) prescan is sufficient to obtain the necessary coil sensitivity information and reference images that are used to reconstruct standard images, so that standard analysis methods are applicable. A moving dots stimulus paradigm was chosen to assess the performance of GIN. We find that the spatial localization of activation for GIN is comparable to an EPI protocol and that maximum z-scores increase significantly. The high temporal resolution of GIN (50 ms) and the acquisition of the phase information enable unaliased sampling and regression of physiological signals. Using the phase time courses obtained from the 32 channels of the receiver coils as nuisance regressors in a general linear model results in significant improvement of the functional activation, rendering the acquisition of external physiological signals unnecessary. The proposed physiological noise correction can in principle be used for other fMRI protocols, such as simultaneous multislice acquisitions, which acquire the phase information sufficiently fast and sample physiological signals unaliased. Copyright © 2012 Wiley Periodicals, Inc.

  14. Diffusion-weighted MR imaging of ring-enhancing intracerebral lesions

    International Nuclear Information System (INIS)

    Li Youcheng; Li Jiance; Tian Wei; Li Zongfang

    2005-01-01

    Objective: To assess the diagnostic value of diffusion-weighted echo-planar MR Imaging (DWI) in ring-enhancing intracerebral lesions. Methods: Magnetic resonance diffusion-weighted images of ninty-three patients presenting with ring-ehancing intracerebral lesions diagnosed by clinical or histopathologic findings were studied retrospectively, including 21 gliomas, 26 metastases, 13 pyogenic abscesses, 18 neurocysticercoses and 15 subacute intracerebral hematomas. The signal intensity ratio on diffusion-weighted images and exponential diffusion coefficient images was calculated respectively in ring walls, central contents, and perilesional edemas of ring-enhancing lesions, and normal contralateral cerebral parenchyma was used for comparison. ADC values of interest of lesions, contralateral cerebral parenchyma and CFS were calculated as well. Results: In pyogenic abscesses and subacute intracerebral hematomas, the central content was always extremely hyperintense on diffusion-weighted images, and showed low ADCs [(0.56 ± 0.20) x 10 -3 mm 2 /s, (0.69 ± 0.16) x 10 -3 mm 2 /s, respectively]. On the other hand the central content of gliomas, metastases and neurocysticercoses was hypointense, and showed high ADCs [(2.76 ± 0.41 ) x 10 -3 mm 2 /s, (2.31 ± 0.39 ) x 10 -3 mm 2 /s, (2.10 ± 0.32) x 10 -3 mm 2 /s, respectively]. The ADCs of the first two lesions were significantly lower than of the last three lesions (P 2 -weighted images should be reviewed in daily clinical practice. (authors)

  15. Role of T2 weighted magnetic resonance image in chronic phase of head injured patients

    International Nuclear Information System (INIS)

    Uzura, Masahiko; Taguchi, Yoshio; Watanabe, Hiroyuki; Chiba, Syunmei; Matsuzawa, Motoshi

    2002-01-01

    In neuroimaging studies of head injury, addition of echo planar imaging (EPI) T2-weighted images (WI) to routine MR images has been useful in demonstrating small hemorrhagic lesions as magnetic susceptibility artifacts (MSAs). MSAs are often found in the acute or subacute phases of head injured patients with diffuse axonal injury. We studied MSAs in follow-up MR images of patients with diffuse brain injury and discuss the role of EPI T2-WI in patients with chronic phase of head injured patients. This series consisted of 20 patients with diffuse brain injury diagnosed clinically. Their head CT findings were classified into Diffuse Injury I or II according to the CT classification of Marshall et al. All patients underwent long-term follow-up MR examinations. MR findings in chronic phase were divided into three categories in terms of MSAs: group A, MSAs remaining even after disappearance of small traumatic lesions in both T2-WI and fluid attenuated inversion recovery (FLAIR) images (11 cases); group B, MSA (s) that disappeared in association with disappearance of small traumatic lesions (4 cases); and group C, MSAs that remained but could not be differentiated from non-traumatic lesions such as hemorrhagic lacunae or cavernoma (5 cases). Adding EPI T2-WI to routine MR images can provide useful information in visualizing old traumatic lesions of the brain in patients with diffuse brain injury even if no neuroimaging studies in acute or subacute phase. (author)

  16. Single-shot fluctuations in waveguided high-harmonic generation

    NARCIS (Netherlands)

    Goh, S.J.; Tao, Y.; van der Slot, Petrus J.M.; Bastiaens, Hubertus M.J.; Herek, Jennifer Lynn; Biedron, S.G.; Danailov, M.B.; Milton, S.V.; Boller, Klaus J.

    2015-01-01

    For exploring the application potential of coherent soft x-ray (SXR) and extreme ultraviolet radiation (XUV) provided by high-harmonic generation, it is important to characterize the central output parameters. Of specific importance are pulse-to-pulse (shot-to-shot) fluctuations of the high-harmonic

  17. The challenges of single-shot spinal anaesthesia for cesearean ...

    African Journals Online (AJOL)

    An unusual case of morbid obesity, severe hypertension and twin gestation at 36weeks in an unbooked multigravid patient was presented for cesarean section. She was referred from a private clinic to the obstetric emergency unit of the University College Hospital, Ibadan with history of hypertension in pregnancy. She was ...

  18. Single-shot optical conductivity measurement of dense aluminum plasmas

    International Nuclear Information System (INIS)

    Churina, I. V.; Cho, B.-I.; Bernstein, A.; Stoker, D. S.; Dalton, A.; Symes, D. R.; Ditmire, T.

    2009-01-01

    The optical conductivity of a dense femtosecond laser-heated aluminum plasma heated to 0.1-1.5 eV was measured using frequency-domain interferometry with chirped pulses, permitting simultaneous observation of optical probe reflectivity and probe pulse phase shift. Coupled with published models of bound-electron contributions to the conductivity, these two independent experimental data yielded a direct measurement of both real and imaginary components of the plasma conductivity.

  19. Whole-body intravoxel incoherent motion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Filli, Lukas; Wurnig, Moritz C.; Eberhardt, Christian; Guggenberger, Roman; Boss, Andreas [University Hospital Zurich, Department of Radiology, Zurich (Switzerland); Luechinger, Roger [University and ETH Zurich, Institute of Biomedical Technology, Zurich (Switzerland)

    2015-07-15

    To investigate the technical feasibility of whole-body intravoxel incoherent motion (IVIM) imaging. Whole-body MR images of eight healthy volunteers were acquired at 3T using a spin-echo echo-planar imaging sequence with eight b-values. Coronal parametrical whole-body maps of diffusion (D), pseudodiffusion (D*), and the perfusion fraction (F{sub p}) were calculated. Image quality was rated qualitatively by two independent radiologists, and inter-reader reliability was tested with intra-class correlation coefficients (ICCs). Region of interest (ROI) analysis was performed in the brain, liver, kidney, and erector spinae muscle. Depiction of anatomic structures was rated as good on D maps and good to fair on D* and F{sub p} maps. Exemplary mean D (10{sup -3} mm{sup 2}/s), D* (10{sup -3} mm{sup 2}/s) and F{sub p} (%) values (± standard deviation) of the renal cortex were as follows: 1.7 ± 0.2; 15.6 ± 6.5; 20.9 ± 4.4. Inter-observer agreement was ''substantial'' to ''almost perfect'' (ICC = 0.80 - 0.92). The coefficient of variation of D* was significantly lower with the proposed algorithm compared to the conventional algorithm (p < 0.001), indicating higher stability. The proposed IVIM protocol allows computation of parametrical maps with good to fair image quality. Potential future clinical applications may include characterization of widespread disease such as metastatic tumours or inflammatory myopathies. (orig.)

  20. MR diffusion tensor analysis of schizophrenic brain using statistical parametric mapping

    International Nuclear Information System (INIS)

    Yamada, Haruyasu; Abe, Osamu; Kasai, Kiyoto

    2005-01-01

    The purpose of this study is to investigate diffusion anisotropy in the schizophrenic brain by voxel-based analysis of diffusion tensor imaging (DTI), using statistical parametric mapping (SPM). We studied 33 patients with schizophrenia diagnosed by diagnostic and statistical manual of mental disorders (DSM)-IV criteria and 42 matched controls. The data was obtained with a 1.5 T MRI system. We used single-shot spin-echo planar sequences (repetition time/echo time (TR/TE)=5000/102 ms, 5 mm slice thickness and 1.5 mm gap, field of view (FOV)=21 x 21 cm 2 , number of excitation (NEX)=4, 128 x 128 pixel matrix) for diffusion tensor acquisition. Diffusion gradients (b-value of 500 or 1000 s/mm 2 ) were applied on two axes simultaneously. Diffusion properties were measured along 6 non-linear directions. The structural distortion induced by the large diffusion gradients was corrected, based on each T 2 -weighted echo-planar image (b=0 s/mm 2 ). The fractional anisotropy (FA) maps were generated on a voxel-by-voxel basis. T 2 -weighted echo-planar images were then segmented into gray matter, white matter, and cerebrospinal fluid, using SPM (Wellcome Department of Imaging, University College London, UK). All apparent diffusion coefficient (ADC) and FA maps in native space were transformed to the stereotactic space by registering each of the images to the same template image. The normalized data was smoothed and analyzed using SPM. The significant FA decrease in the patient group was found in the uncinate fasciculus, parahippocampal white matter, anterior cingulum and other areas (corrected p<0.05). No significant increased region was noted. Our results may reflect reduced diffusion anisotropy of the white matter pathway of the limbic system as shown by the decreased FA. Manual region-of-interest analysis is usually more sensitive than voxel-based analysis, but it is subjective and difficult to set with anatomical reproducibility. Voxel-based analysis of the diffusion tensor

  1. Imaging nanoscale spatial modulation of a relativistic electron beam with a MeV ultrafast electron microscope

    Science.gov (United States)

    Lu, Chao; Jiang, Tao; Liu, Shengguang; Wang, Rui; Zhao, Lingrong; Zhu, Pengfei; Liu, Yaqi; Xu, Jun; Yu, Dapeng; Wan, Weishi; Zhu, Yimei; Xiang, Dao; Zhang, Jie

    2018-03-01

    An accelerator-based MeV ultrafast electron microscope (MUEM) has been proposed as a promising tool to the study structural dynamics at the nanometer spatial scale and the picosecond temporal scale. Here, we report experimental tests of a prototype MUEM where high quality images with nanoscale fine structures were recorded with a pulsed ˜3 MeV picosecond electron beam. The temporal and spatial resolutions of the MUEM operating in the single-shot mode are about 4 ps (FWHM) and 100 nm (FWHM), corresponding to a temporal-spatial resolution of 4 × 10-19 s m, about 2 orders of magnitude higher than that achieved with state-of-the-art single-shot keV UEM. Using this instrument, we offer the demonstration of visualizing the nanoscale periodic spatial modulation of an electron beam, which may be converted into longitudinal density modulation through emittance exchange to enable production of high-power coherent radiation at short wavelengths. Our results mark a great step towards single-shot nanometer-resolution MUEMs and compact intense x-ray sources that may have widespread applications in many areas of science.

  2. Diffusion-weighted MR imaging of kidneys in patients with chronic kidney disease: initial study

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Xueqin; Fang, Wenqiang; Ling, Huawei; Chai, Weimin; Chen, Kemin [Ruijin Hospital Shanghai, Jiaotong University School of Medicine, Department of Radiology, Shanghai (China)

    2010-04-15

    To prospectively evaluate the feasibility of diffusion-weighted (DW) magnetic resonance (MR) imaging in the assessment of renal function in patients with chronic kidney disease (CKD). Seventy-two healthy volunteers and 43 patients underwent coronal echo-planar DW MR imaging of the kidneys with a single breath-hold time of 16 s. The patients were grouped according to five stages as indicated by the K/DOQI CKD (kidney disease outcome quality initiative). The apparent diffusion coefficient (ADC) value of the kidneys was calculated with high b values (b = 500 s/mm{sup 2}). The ADC values were compared between patients and healthy volunteers, and among different stages. For statistical analysis, Student's t tests, ANOVA, Pearson's correlation tests, and Spearman's correlation tests were used. No difference between the cortex and medulla could be observed on DW images of all volunteers. Patients with CKD had significantly lower renal ADC (t = -4.383, P = 0.000) than volunteers. The ADC values of kidneys were significantly lower than normal at most stages of CKD, except CKD1. There was a negative correlation between the ADCs and serum creatinine (sCr) level (P = 0.000) amongst the patients. Diffusion-weighted MR imaging is feasible in the assessment of renal function, especially in the detection of early stage renal failure of CKD. (orig.)

  3. Time-optimized high-resolution readout-segmented diffusion tensor imaging.

    Directory of Open Access Journals (Sweden)

    Gernot Reishofer

    Full Text Available Readout-segmented echo planar imaging with 2D navigator-based reacquisition is an uprising technique enabling the sampling of high-resolution diffusion images with reduced susceptibility artifacts. However, low signal from the small voxels and long scan times hamper the clinical applicability. Therefore, we introduce a regularization algorithm based on total variation that is applied directly on the entire diffusion tensor. The spatially varying regularization parameter is determined automatically dependent on spatial variations in signal-to-noise ratio thus, avoiding over- or under-regularization. Information about the noise distribution in the diffusion tensor is extracted from the diffusion weighted images by means of complex independent component analysis. Moreover, the combination of those features enables processing of the diffusion data absolutely user independent. Tractography from in vivo data and from a software phantom demonstrate the advantage of the spatially varying regularization compared to un-regularized data with respect to parameters relevant for fiber-tracking such as Mean Fiber Length, Track Count, Volume and Voxel Count. Specifically, for in vivo data findings suggest that tractography results from the regularized diffusion tensor based on one measurement (16 min generates results comparable to the un-regularized data with three averages (48 min. This significant reduction in scan time renders high resolution (1 × 1 × 2.5 mm(3 diffusion tensor imaging of the entire brain applicable in a clinical context.

  4. Diffusion-weighted MR imaging of kidneys in patients with chronic kidney disease: initial study

    International Nuclear Information System (INIS)

    Xu, Xueqin; Fang, Wenqiang; Ling, Huawei; Chai, Weimin; Chen, Kemin

    2010-01-01

    To prospectively evaluate the feasibility of diffusion-weighted (DW) magnetic resonance (MR) imaging in the assessment of renal function in patients with chronic kidney disease (CKD). Seventy-two healthy volunteers and 43 patients underwent coronal echo-planar DW MR imaging of the kidneys with a single breath-hold time of 16 s. The patients were grouped according to five stages as indicated by the K/DOQI CKD (kidney disease outcome quality initiative). The apparent diffusion coefficient (ADC) value of the kidneys was calculated with high b values (b = 500 s/mm 2 ). The ADC values were compared between patients and healthy volunteers, and among different stages. For statistical analysis, Student's t tests, ANOVA, Pearson's correlation tests, and Spearman's correlation tests were used. No difference between the cortex and medulla could be observed on DW images of all volunteers. Patients with CKD had significantly lower renal ADC (t = -4.383, P = 0.000) than volunteers. The ADC values of kidneys were significantly lower than normal at most stages of CKD, except CKD1. There was a negative correlation between the ADCs and serum creatinine (sCr) level (P = 0.000) amongst the patients. Diffusion-weighted MR imaging is feasible in the assessment of renal function, especially in the detection of early stage renal failure of CKD. (orig.)

  5. Diffusion-weighted whole-body MR imaging with background body signal suppression: a feasibility study at 3.0 Tesla

    International Nuclear Information System (INIS)

    Muertz, Petra; Krautmacher, Carsten; Traeber, Frank; Schild, Hans H.; Willinek, Winfried A.; Gieseke, Juergen

    2007-01-01

    The purpose was to provide a diffusion-weighted whole-body magnetic resonance (MR) imaging sequence with background body signal suppression (DWIBS) at 3.0 Tesla. A diffusion-weighted spin-echo echo-planar imaging sequence was combined with the following methods of fat suppression: short TI inversion recovery (STIR), spectral attenuated inversion recovery (SPAIR), and spectral presaturation by inversion recovery (SPIR). Optimized sequences were implemented on a 3.0- and a 1.5-Tesla system and evaluated in three healthy volunteers and six patients with various lesions in the neck, chest, and abdomen on the basis of reconstructed maximum intensity projection images. In one patient with metastases of malignant melanoma, DWIBS was compared with 18 F-fluorodeoxyglucose positron emission tomography (FDG-PET). Good fat suppression for all regions and diagnostic image quality in all cases could be obtained at 3.0 Tesla with the STIR method. In comparison with 1.5 Tesla, DWIBS images at 3.0 Tesla were judged to provide a better lesion-to-bone tissue contrast. However, larger susceptibility-induced image distortions and signal intensity losses, stronger blurring artifacts, and more pronounced motion artifacts degraded the image quality at 3.0 Tesla. A good correlation was found between the metastases as depicted by DWIBS and those as visualized by FDG-PET. DWIBS is feasible at 3.0 Tesla with diagnostic image quality. (orig.)

  6. Assessment of the image quality and tumor detectability of breath-hold T2-weighted imaging of liver tumors using a fast gradient MR system

    International Nuclear Information System (INIS)

    Yoshida, Kotaro; Suto, Yuji; Sugihara, Shuji; Tokuda, Yukiko

    1996-01-01

    Fourteen patients with various types of focal liver tumors were imaged with turbo spin-echo (TSE), breath-hold TSE (BH-TSE) and half-Fourier single-shot TSE (HASTE) pulse sequences using a fast gradient magnetic resonance imaging (MRI) system. We compared the T2-weighted images of the liver with the TSE, BH-TSE, HASTE and conventional spin-echo (SE) pulse sequences in order to determine whether those fast T2-weighted images, including fat suppressed images, could replace SE images. In quantitative and qualitative analysis, the fast T2-weighted images were slightly superior to the SE images, but they were inferior in the conspicuousness of liver tumor to the SE images. These findings suggest that the fast T2-weighted images can shorten the examination time of the liver MRI, but cannot replace the T2-weighted SE images because of the low conspicuousness. (author)

  7. A variational image-based approach to the correction of susceptibility artifacts in the alignment of diffusion weighted and structural MRI.

    Science.gov (United States)

    Tao, Ran; Fletcher, P Thomas; Gerber, Samuel; Whitaker, Ross T

    2009-01-01

    This paper presents a method for correcting the geometric and greyscale distortions in diffusion-weighted MRI that result from inhomogeneities in the static magnetic field. These inhomogeneities may due to imperfections in the magnet or to spatial variations in the magnetic susceptibility of the object being imaged--so called susceptibility artifacts. Echo-planar imaging (EPI), used in virtually all diffusion weighted acquisition protocols, assumes a homogeneous static field, which generally does not hold for head MRI. The resulting distortions are significant, sometimes more than ten millimeters. These artifacts impede accurate alignment of diffusion images with structural MRI, and are generally considered an obstacle to the joint analysis of connectivity and structure in head MRI. In principle, susceptibility artifacts can be corrected by acquiring (and applying) a field map. However, as shown in the literature and demonstrated in this paper, field map corrections of susceptibility artifacts are not entirely accurate and reliable, and thus field maps do not produce reliable alignment of EPIs with corresponding structural images. This paper presents a new, image-based method for correcting susceptibility artifacts. The method relies on a variational formulation of the match between an EPI baseline image and a corresponding T2-weighted structural image but also specifically accounts for the physics of susceptibility artifacts. We derive a set of partial differential equations associated with the optimization, describe the numerical methods for solving these equations, and present results that demonstrate the effectiveness of the proposed method compared with field-map correction.

  8. Functional magnetic resonance imaging mapping of the motor cortex in patients with cerebral tumors

    International Nuclear Information System (INIS)

    Mueller, W.M.; Zerrin Yetkin, F.; Hammeke, T.A.

    1997-01-01

    Objective. The purpose of this study was to determine the usefulness of functional magnetic resonance imaging (FMRI) to map cerebral functions in patients with frontal or parietal tumors. Methods. Charts and images of patients with cerebral tumors or vascular malformations who underwent FMRI with an echo-planar technique were reviewed. The FMRI maps of motor (11 patients), tactile sensory (12 patients) and language tasks (4 patients) were obtained. The location of the FMRI activation and the positive responses to intraoperative cortical stimulation were compared. The reliability of the paradigms for mapping the rolandic cortex was evaluated. Results. Rolandic cortex was activated by tactile tasks in hall 12 patients and by motor tasks in 10 of 11 patients. Language tasks elicited activation in each of the four patients. Activation was obtained within edematous brain and adjacent to tumors. FMRI in three cases with intraoperative electro-cortical mapping results showed activation for a language, tactile, or motor task within the same gyrus in which stimulation elicited a related motor, sensory, or language function. In patients with >2 cm between the margin of the tumor, as revealed by magnetic resonance imaging, and the activation, no decline in motor function occurred from surgical resection. Conclusions. FMRI of tactile, motor, and language tasks is feasible in patients with cerebral tumors. FMRI shows promise as a means of determining the risk of a postoperative motor deficit from surgical resection of frontal or parietal tumors. (authors)

  9. Increased self-diffusion of brain water in hydrocephalus measured by MR imaging

    International Nuclear Information System (INIS)

    Gideon, P.; Thomsen, C.; Gjerris, F.; Soerensen, P.S.; Henriksen, O.

    1994-01-01

    We used MR imaging to measure the apparent brain water self-diffusion in 5 patients with normal pressure hydrocephalus (NPH), in 2 patients with high pressure hydrocephalus (HPH), and in 8 agematched controls. In all patients with NPH significant elevations of the apparent diffusion coefficients (ADC) of brain water were found within periventricular white matter, in the corpus callosum, in the internal capsule, within cortical gray matter, and in cerebrospinal fluid, whereas normal ADCs were found within the basal ganglia. In 2 patients with HPH elevated ADCs were found most prominently within white matter and in one patient reexamined one year after surgery. ADCs were unchanged in nearly all brain regions. The increased ADC values in hydrocephalus patients may be caused by factors such as changes in myelin-associated bound water, increased Virchow-Robin spaces, and increased extracellular brain water fraction. For further studies of brain water diffusion in hydrocephalus patients, echo-planar imaging techniques with imaging times of a few seconds may be valuable. (orig.)

  10. Diffusion tensor magnetic resonance imaging of the breast: a pilot study

    International Nuclear Information System (INIS)

    Baltzer, Pascal A.T.; Schaefer, Anja; Dietzel, Matthias; Kaiser, Werner A.; Graessel, David; Gajda, Mieczyslaw; Camara, Oumar

    2011-01-01

    Diffusion-weighted MR imaging has shown diagnostic value for differential diagnosis of breast lesions. Diffusion tensor imaging (DTI) adds information about tissue microstructure by addressing diffusion direction. We have examined the diagnostic application of DTI of the breast. A total of 59 patients (71 lesions: 54 malignant, 17 benign) successfully underwent prospective echo planar imaging-DTI (EPI-DTI) (1.5 T). First, diffusion direction both of parenchyma as well as lesions was assessed on parametric maps. Subsequently, apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values were measured. Statistics included univariate (Mann-Whitney U test, receiver operating analysis) and multivariate (logistic regression analysis, LRA) tests. Main diffusion direction of parenchyma was anterior-posterior in the majority of cases (66.1%), whereas lesions (benign, malignant) showed no predominant diffusion direction in the majority of cases (23.9%). ADC values showed highest differences between benign and malignant lesions (P < 0.001) with resulting area under the curve (AUC) of 0.899. FA values were lower in benign (interquartile range, IR, 0.14-0.24) compared to malignant lesions (IR 0.21-0.35, P < 0.002) with an AUC of 0.751-0.770. Following LRA, FA did not prove to have incremental value for differential diagnosis over ADC values. Microanatomical differences between benign and malignant breast lesions as well as breast parenchyma can be visualized by using DTI. (orig.)

  11. Diffusion-weighted imaging of breast tumours at 3 Tesla and 7 Tesla: a comparison

    Energy Technology Data Exchange (ETDEWEB)

    Gruber, S.; Minarikova, L.; Zaric, O.; Chmelik, M.; Strasser, B.; Trattnig, S.; Bogner, W. [Medical University Vienna, MRCE, Department of Biomedical imaging and Image-Guided Therapy, Vienna (Austria); Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna (Austria); Pinker, K.; Baltzer, P.; Helbich, T. [Medical University Vienna, Division of Molecular and Gender Imaging, Department of Biomedical imaging and Image-Guided Therapy, Vienna (Austria)

    2016-05-15

    To compare bilateral diffusion-weighted MR imaging (DWI) at 3 T and 7 T in the same breast tumour patients. Twenty-eight patients were included in this IRB-approved study (mean age 56 ± 16 years). Before contrast-enhanced imaging, bilateral DWI with b = 0 and 850 s/mm{sup 2} was performed in 2:56 min (3 T) and 3:48 min (7 T), using readout-segmented echo planar imaging (rs-EPI) with a 1.4 x 1.4 mm{sup 2} (3 T)/0.9 x 0.9 mm{sup 2} (7 T) in-plane resolution. Apparent diffusion coefficients (ADC), signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were assessed. Twenty-eight lesions were detected (18 malignant, 10 benign). CNR and SNR were comparable at both field strengths (p > 0.3). Mean ADC values at 7 T were 4-22 % lower than at 3 T (p ≤ 0.03). An ADC threshold of 1.275 x 10{sup -3} mm{sup 2}/s resulted in a diagnostic specificity of 90 % at both field strengths. The sensitivity was 94 % and 100 % at 3 T and 7 T, respectively. 7-T DWI of the breast can be performed with 2.4-fold higher spatial resolution than 3 T, without significant differences in SNR if compared to 3 T. (orig.)

  12. Magnetic resonance imaging of the active second stage of labour: Proof of principle

    International Nuclear Information System (INIS)

    Guettler, F.V.; Heinrich, A.; Rump, J.; Bucourt, M. de; Hamm, B.; Teichgraeber, U.K.; Schnackenburg, B.; Bamberg, C.

    2012-01-01

    To prove that magnetic resonance imaging of foetal anatomy during the active second stage of vaginal delivery is feasible. Initially, five pregnant volunteers around the 30th week of gestation were examined in an open MRI. Based on the findings, one vaginal delivery was acquired under real-time imaging. To monitor the birth status during image acquisition, an MR-compatible wireless cardiotocography (CTG) system was built. Single-shot sequence parameters were optimised to compensate motion artefacts during labour. Safety requirements to monitor the birth process under real-time MR imaging were met. High-resolution MR images were acquired immediately before and after delivery. In one patient, TSE single-shot cinematic sequences of the active second stage of labour were obtained. All sequences were adapted to tolerate movement of the mother and infant, as well as residual noise from the CTG. Furthermore, the MR imaging during labour showed only minor image artefacts. CTG-monitored acquisition of MRI series during the active second stage of delivery is feasible. Image quality should allow various further studies to improve models for birth simulation as well as potential investigation of obstructed labour and obstetric complications. (orig.)

  13. Preliminary clinical applications of DTI in human cervical spinal cord

    International Nuclear Information System (INIS)

    Song Ting; Mai Weiwen; Liang Biling; Shen Jun; Huang Suiqiao; Hu Chunhong

    2007-01-01

    Objective: To condcut preliminary study of the value of DTI(diffusion tensor imaging) in human cervical spinal cord. Methods: Twenty-one patients suffering from cervical spondylotic myelopathy and twenty volunteers without any clinical symptoms underwent routine MRI and DTI examination. DTI was performed in six non-collinear directions with single-shot fast spin echo echo, planar imaging sequence(b value = 400 s·mm -2 ). ADC(apparent diffusion coefficient) and FA(fractional anisotropy)values were measured by ROIs(regions of interest) in 4 different level segment spinal cord (C 2/3 , C 3/4 , C 4/5 , C 5/6 ) in normal volunteers, in lesions and normal segmental spinal cord in clinical cases respectively. DTI original images were automatically processed by using IDL (Version 5.6) soft- ware to produce color tensor images. SPSS11.0 software for windows was used for t-test and one-way ANOVA analysis. The difference was considered statistically significant if P 2/3 , C 3/4 , C 4/5 , C 5/6 , were analyzed and it was found that FA value between them had a significant difference by ANOVA, F=159.24, P 2/3 level. However, ADC value between 4 segments had no significant difference(F=2.191, P>0.05). (2)In patients of cervical spondylotic myelopathy, routine MRI T2WI showed abnormal signal in 9 cases, and showed no abnormal signal in 12 dases. In sixteen cases it was found that abnormal patchy green signal on colorized tensor maps appeared on the normal blue spinal cord. Also, in patients of cervical spondylotic myelopathy, there was significant difference in ADC and FA value between lesions and normal spinal cord (paired t test, for ADC, t=2.88, P 2/3 level segment spinal cord in normal volunteers (0.85 ± 0.03) is the highest among other segments. FA value decreases gradually along cervical spinal cord towards the caudal direction. However, the difference of ADC values amongst 4 segments is not significant. DTI colorized tensor maps can show more lesions than routine MRI

  14. Combination of chemical suppression techniques for dual suppression of fat and silicone at diffusion-weighted MR imaging in women with breast implants

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Dow-Mu; Hughes, J. [Royal Marsden Hospital, Department of Radiology, Sutton (United Kingdom); Blackledge, M.; Leach, M.O.; Collins, D.J. [Institute of Cancer Research, CR UK-EPSRC Cancer Imaging Centre, Sutton (United Kingdom); Burns, S. [Nuada 3T MRI Centre, London (United Kingdom); Stemmer, A.; Kiefer, B. [Siemens Healthcare, Erlangen (Germany)

    2012-12-15

    Silicone breast prostheses prove technically challenging when performing diffusion-weighted MR imaging in the breasts. We describe a combined fat and chemical suppression scheme to achieve dual suppression of fat and silicone, thereby improving the quality of diffusion-weighted images in women with breast implants. MR imaging was performed at 3.0 and 1.5 T in women with silicone breast implants using short-tau inversion recovery (STIR) fat-suppressed echo-planar (EPI) diffusion-weighted MR imaging (DWI) on its own and combined with the slice-select gradient-reversal (SSGR) technique. Imaging was performed using dedicated breast imaging coils. Complete suppression of the fat and silicone signal was possible at 3.0 T using EPI DWI with STIR and SSGR, evaluated with dedicated breast coils. However, a residual silicone signal was still perceptible at 1.5 T using this combined approach. Nevertheless, a further reduction in silicone signal at 1.5 T could be achieved by employing thinner slice partitions and the addition of the chemical-selective fat-suppression (CHESS) technique. DWI using combined STIR and SSGR chemical suppression techniques is feasible to eliminate or reduce silicone signal from prosthetic breast implants. (orig.)

  15. Brain involvement in patients with inflammatory bowel disease: a voxel-based morphometry and diffusion tensor imaging study.

    Science.gov (United States)

    Zikou, Anastasia K; Kosmidou, Maria; Astrakas, Loukas G; Tzarouchi, Loukia C; Tsianos, Epameinondas; Argyropoulou, Maria I

    2014-10-01

    To investigate structural brain changes in inflammatory bowel disease (IBD). Brain magnetic resonance imaging (MRI) was performed on 18 IBD patients (aged 45.16 ± 14.71 years) and 20 aged-matched control subjects. The imaging protocol consisted of a sagittal-FLAIR, a T1-weighted high-resolution three-dimensional spoiled gradient-echo sequence, and a multisession spin-echo echo-planar diffusion-weighted sequence. Differences between patients and controls in brain volume and diffusion indices were evaluated using the voxel-based morphometry (VBM) and tract-based spatial statistics (TBSS) methods, respectively. The presence of white-matter hyperintensities (WMHIs) was evaluated on FLAIR images. VBM revealed decreased grey matter (GM) volume in patients in the fusiform and the inferior temporal gyrus bilaterally, the right precentral gyrus, the right supplementary motor area, the right middle frontal gyrus and the left superior parietal gyrus (p tensor imaging detects microstructural brain abnormalities in IBD. • Voxel based morphometry reveals brain atrophy in IBD.

  16. Perfusion imaging with magnetic-susceptibility contrast media

    International Nuclear Information System (INIS)

    Rosen, B.R.; Belliveau, J.W.; Betteridge, D.; Cohen, M.S.; Weisskoff, R.M.; Vevea, J.M.; Rzedzian, R.P.; Brady, T.J.

    1989-01-01

    In animal models, transient signal los on T2-weighted images has been well documented following intravenous injection of high-magnetic-susceptibility contrast agents that are compartmentalized within the brain intravascular space. These signal changes have been correlated with physiologic parameters, such as blood flow and volume. The advent of whole-body single-shot imaging capability, coupled with the approval of paramagnetic contrasts agents for human use, has enabled the authors to demonstrate susceptibility contrast in the human brain, allowing for generation of functional images. With use of a 1.5-T imaging system gradient-echo images (TE = 60 msec) were acquired in 75 msec. Sequential single-sections images were sampled every 1 second following bolus administration of 0.1 mmol/kg of Gd-DTPA

  17. Role of diffusion-weighted MR imaging in characterization of cervical lesions

    International Nuclear Information System (INIS)

    Salik, E.; Islim, F.; Ciftci, G.; Bayramoglu, S.; Sever, N.

    2012-01-01

    Full text: Introduction: Characterization of neck lesions is usually not possible without histopathological examination. Objective: To evaluate whether adhesion diffusion coefficient (ADC) values calculated from diffusion weighted magnetic resonance imaging can be used to characterize neck lesions. Material and methods: Diffusion-weighted echo planar MR imaging with b factors of 0, 500 and 1000 sec/mm 2 was prospectively performed with a 1.5 T MR unit in 119 neck lesions in 119 patients. ADC values were measured by 2 radiologists independently on an independent workstation console. Intraclass correlation coefficients were calculated. The mean ADC values were compared using Mann-whitney u test. Results: There was a statistically significant difference between the mean ADC values of benign and malign solid lesions (1.13±0.62 x 10 -3 mm 2 /s and 0.82±0.21 x 10 -3 mm 2 /s respectively). There was no malign lesion with an ADC value more than 1.15 x 10 -3 mm 2 /s. The mean ADC value of malignant lymphomas (0.61±0.14 x 10 -3 ) was significantly smaller than the mean ADC values of other cervical lymphadenopathies. But there was no statistically significant difference between the mean ADC values of reactive, granulomatous and metastatic lymph nodes. Conclusion: ADC values cannot totally distinguish the histopathological subgroups of the neck lesions but shows significant differences between malign and benign lesions.

  18. Functional magnetic resonance imaging in primary writing tremor and writer’s cramp: A pilot study

    Science.gov (United States)

    Sahni, Hirdesh; Jayakumar, Peruvumba N.; Pal, Pramod Kumar

    2010-01-01

    Objectives: The precise pathophysiology of primary writing tremor (PWT) and writer’s cramp (WC) is not known. The aim of this study is to compare the cerebral activation patterns in patients of PWT, WC and healthy controls, during a task of signing on paper, using functional magnetic resonance imaging (fMRI). Materials and Methods: Six subjects with PWT, three with WC and six healthy volunteers were examined using a 1.5-Tesla scanner. The paradigm consisted of three times repetition of a set of period of rest and activity. Each set consisted of 10 blood oxygen level dependent (BOLD) echo-planar imaging (EPI) acquisitions at rest followed by 10 BOLD EPI acquisitions while signing their names on paper using the dominant right hand. Entire brain was covered. SPM99 analysis was done. Results: In comparison to the healthy controls, the following differences in cerebral activation were noted in the patients: (a) primary and supplementary motor areas showed overactivation in patients of PWT and underactivation in patients of WC, (b) the cingulate motor area showed underactivation in patients of PWT and overactivation in patients of WC and (c) the cerebellar activity was reduced in both WC and PWT. Conclusion: Our preliminary findings suggest that the cerebral and cerebellar activation patterns in PWT and WC during signing on paper are distinct from each other and from healthy controls. There may be cerebellar dysfunction in addition to motor dysfunctions in the pathogenesis of these disorders. PMID:21085530

  19. Renal water molecular diffusion characteristics in healthy native kidneys: assessment with diffusion tensor MR imaging.

    Directory of Open Access Journals (Sweden)

    Zhenfeng Zheng

    Full Text Available BACKGROUND: To explore the characteristics of diffusion tensor imaging (DTI and magnetic resonance (MR imaging in healthy native kidneys. METHODS: Seventy-three patients without chronic kidney disease underwent DTI-MRI with spin echo-echo planar (SE-EPI sequences accompanied by an array spatial sensitivity encoding technique (ASSET. Cortical and medullary mean, axial and radial diffusivity (MD, AD and RD, fractional anisotropy (FA and primary, secondary and tertiary eigenvalues (λ1, λ2, λ3 were analysed in both kidneys and in different genders. RESULTS: Cortical MD, λ2, λ3, and RD values were higher than corresponding medullary values. The cortical FA value was lower than the medullary FA value. Medullary λ1 and RD values in the left kidney were lower than in the right kidney. Medullary λ2, and λ3 values in women were higher than those in men. Medullary FA values in women were lower than those in men. Medullary FA (r = 0.351, P = 0.002 and λ1 (r = 0.277, P = 0.018 positively correlated with eGFR. Medullary FA (r = -0.25, P = 0.033 negatively correlated with age. CONCLUSIONS: Renal water molecular diffusion differences exist in human kidneys and genders. Age and eGFR correlate with medullary FA and primary eigenvalue.

  20. Diffusion tensor imaging and tractography for assessment of renal allograft dysfunction - initial results

    Energy Technology Data Exchange (ETDEWEB)

    Hueper, Katja; Gutberlet, M.; Rodt, T.; Wacker, F.; Galanski, M.; Hartung, D. [Institute for Diagnostic and Interventional Radiology, Hannover Medical School - Germany, Hannover (Germany); Gwinner, W. [Clinic for Nephrology, Hannover Medical School - Germany, Hannover (Germany); Lehner, F. [Clinic for General, Abdominal and Transplant Surgery, Hannover Medical School - Germany, Hannover (Germany)

    2011-11-15

    To evaluate MR diffusion tensor imaging (DTI) as non-invasive diagnostic tool for detection of acute and chronic allograft dysfunction and changes of organ microstructure. 15 kidney transplanted patients with allograft dysfunction and 14 healthy volunteers were examined using a fat-saturated echo-planar DTI-sequence at 1.5 T (6 diffusion directions, b = 0, 600 s/mm{sup 2}). Mean apparent diffusion coefficient (ADC) and mean fractional anisotropy (FA) were calculated separately for the cortex and for the medulla and compared between healthy and transplanted kidneys. Furthermore, the correlation between diffusion parameters and estimated GFR was determined. The ADC in the cortex and in the medulla were lower in transplanted than in healthy kidneys (p < 0.01). Differences were more distinct for FA, especially in the renal medulla, with a significant reduction in allografts (p < 0.001). Furthermore, in transplanted patients a correlation between mean FA in the medulla and estimated GFR was observed (r = 0.72, p < 0.01). Tractography visualized changes in renal microstructure in patients with impaired allograft function. Changes in allograft function and microstructure can be detected and quantified using DTI. However, to prove the value of DTI for standard clinical application especially correlation of imaging findings and biopsy results is necessary. (orig.)

  1. Detection of fast oscillating magnetic fields using dynamic multiple TR imaging and Fourier analysis.

    Directory of Open Access Journals (Sweden)

    Ki Hwan Kim

    Full Text Available Neuronal oscillations produce oscillating magnetic fields. There have been trials to detect neuronal oscillations using MRI, but the detectability in in vivo is still in debate. Major obstacles to detecting neuronal oscillations are (i weak amplitudes, (ii fast oscillations, which are faster than MRI temporal resolution, and (iii random frequencies and on/off intervals. In this study, we proposed a new approach for direct detection of weak and fast oscillating magnetic fields. The approach consists of (i dynamic acquisitions using multiple times to repeats (TRs and (ii an expanded frequency spectral analysis. Gradient echo echo-planar imaging was used to test the feasibility of the proposed approach with a phantom generating oscillating magnetic fields with various frequencies and amplitudes and random on/off intervals. The results showed that the proposed approach could precisely detect the weak and fast oscillating magnetic fields with random frequencies and on/off intervals. Complex and phase spectra showed reliable signals, while no meaningful signals were observed in magnitude spectra. A two-TR approach provided an absolute frequency spectrum above Nyquist sampling frequency pixel by pixel with no a priori target frequency information. The proposed dynamic multiple-TR imaging and Fourier analysis are promising for direct detection of neuronal oscillations and potentially applicable to any pulse sequences.

  2. Functional evaluation of the kidney by diffusion-weighted MR imaging

    International Nuclear Information System (INIS)

    Hasegawa, Taro; Hasegawa, Norio; Irie, Takeo; Fukuda, Kunihiko

    2003-01-01

    The purpose of this study was to determine the relationship between the apparent diffusion coefficient (ADC) and diffuse renal disease by diffusion-weighted echo planar magnetic resonance (MR) imaging (EPI). Ten volunteers, seven patients with chronic renal failure and eighteen recipients of renal transplants were examined with diffusion-weighted EPI. We compared renal function (serum creatinine level) with provided ADC value. The average ADC values were 2.63 x 10 -3 mm 2 /sec for the whole kidney, 2.67 x 10 -3 mm 2 /sec for the cortex and 2.61 x 10 -3 mm 2 /sec for the medulla in normal kidneys. ADC values in the whole kidney, the cortex and the medulla in chronic renal failure were significantly lower than those for normal kidneys. In renal transplantation kidneys, the ADC values in the cortex were significantly lower than those for normal kidney. There was a linear correlation between ADC value and serum creatinine level. Our results show that diffusion-weighted MR imaging may be useful to identify renal dysfunction. (author)

  3. Diffusion tensor imaging of the brain. Effects of distortion correction with correspondence to numbers of encoding directions

    International Nuclear Information System (INIS)

    Yoshikawa, Takeharu; Aoki, Shigeki; Abe, Osamu; Hayashi, Naoto; Masutani, Yoshitaka; Masumoto, Tomohiko; Mori, Harushi; Satake, Yoshiroh; Ohtomo, Kuni

    2008-01-01

    The aim of the study was to estimate the effect of distortion correction with correspondence to numbers of encoding directions to acquire diffusion tensor imaging (DTI) of improved quality. Ten volunteers underwent DTI of the head using echo planar imaging with 6, 13, 27, and 55 encoding directions. Fractional anisotropy (FA) maps and apparent diffusion coefficient (ADC) maps were created before and after distortion correction. Regions of interest were placed in the corpus callosum on each map, and standard deviations of FA and ADC were calculated. FA maps were also evaluated visually by experienced neuroradiologists. Dispersion of standard deviations tended to be reduced after distortion correction, with significant differences found in FA maps with 6 encoding directions, ADC maps with 6 directions, and ADC maps with 13 directions (P<0.001, P<0.005, and P<0.05, respectively). Visual image quality was improved after distortion correction (P<0.01 for all of the visual comparisons). Distortion correction is effective in providing DTI of enhanced quality, notwithstanding the number of encoding directions. (author)

  4. Image Artifacts in Concurrent Transcranial Magnetic Stimulation (TMS) and fMRI Caused by Leakage Currents: Modeling and Compensation

    Science.gov (United States)

    Weiskopf, Nikolaus; Josephs, Oliver; Ruff, Christian C; Blankenburg, Felix; Featherstone, Eric; Thomas, Anthony; Bestmann, Sven; Driver, Jon; Deichmann, Ralf

    2009-01-01

    Purpose To characterize and eliminate a new type of image artifact in concurrent transcranial magnetic stimulation and functional MRI (TMS-fMRI) caused by small leakage currents originating from the high-voltage capacitors in the TMS stimulator system. Materials and Methods The artifacts in echo-planar images (EPI) caused by leakage currents were characterized and quantified in numerical simulations and phantom studies with different phantom-coil geometries. A relay-diode combination was devised and inserted in the TMS circuit that shorts the leakage current. Its effectiveness for artifact reduction was assessed in a phantom scan resembling a realistic TMS-fMRI experiment. Results The leakage-current-induced signal changes exhibited a multipolar spatial pattern and the maxima exceeded 1% at realistic coil-cortex distances. The relay-diode combination effectively reduced the artifact to a negligible level. Conclusion The leakage-current artifacts potentially obscure effects of interest or lead to false-positives. Since the artifact depends on the experimental setup and design (eg, amplitude of the leakage current, coil orientation, paradigm, EPI parameters), we recommend its assessment for each experiment. The relay-diode combination can eliminate the artifacts if necessary. J. Magn. Reson. Imaging 2009;29:1211–1217. © 2009 Wiley-Liss, Inc. PMID:19388099

  5. Brain involvement in patients with inflammatory bowel disease: a voxel-based morphometry and diffusion tensor imaging study

    Energy Technology Data Exchange (ETDEWEB)

    Zikou, Anastasia K.; Astrakas, Loukas G.; Tzarouchi, Loukia C.; Argyropoulou, Maria I. [University of Ioannina, Department of Radiology, Medical School, Ioannina (Greece); Kosmidou, Maria; Tsianos, Epameinondas [University of Ioannina, 1st Department of Internal Medicine (Hepato-Gastroenterology Unit), Medical School, Ioannina (Greece)

    2014-10-15

    To investigate structural brain changes in inflammatory bowel disease (IBD). Brain magnetic resonance imaging (MRI) was performed on 18 IBD patients (aged 45.16 ± 14.71 years) and 20 aged-matched control subjects. The imaging protocol consisted of a sagittal-FLAIR, a T1-weighted high-resolution three-dimensional spoiled gradient-echo sequence, and a multisession spin-echo echo-planar diffusion-weighted sequence. Differences between patients and controls in brain volume and diffusion indices were evaluated using the voxel-based morphometry (VBM) and tract-based spatial statistics (TBSS) methods, respectively. The presence of white-matter hyperintensities (WMHIs) was evaluated on FLAIR images. VBM revealed decreased grey matter (GM) volume in patients in the fusiform and the inferior temporal gyrus bilaterally, the right precentral gyrus, the right supplementary motor area, the right middle frontal gyrus and the left superior parietal gyrus (p < 0.05). TBSS showed decreased axial diffusivity (AD) in the right corticospinal tract and the right superior longitudinal fasciculus in patients compared with controls. A larger number of WMHIs was observed in patients (p < 0.05). Patients with IBD show an increase in WMHIs and GM atrophy, probably related to cerebral vasculitis and ischaemia. Decreased AD in major white matter tracts could be a secondary phenomenon, representing Wallerian degeneration. (orig.)

  6. Correction for Eddy Current-Induced Echo-Shifting Effect in Partial-Fourier Diffusion Tensor Imaging.

    Science.gov (United States)

    Truong, Trong-Kha; Song, Allen W; Chen, Nan-Kuei

    2015-01-01

    In most diffusion tensor imaging (DTI) studies, images are acquired with either a partial-Fourier or a parallel partial-Fourier echo-planar imaging (EPI) sequence, in order to shorten the echo time and increase the signal-to-noise ratio (SNR). However, eddy currents induced by the diffusion-sensitizing gradients can often lead to a shift of the echo in k-space, resulting in three distinct types of artifacts in partial-Fourier DTI. Here, we present an improved DTI acquisition and reconstruction scheme, capable of generating high-quality and high-SNR DTI data without eddy current-induced artifacts. This new scheme consists of three components, respectively, addressing the three distinct types of artifacts. First, a k-space energy-anchored DTI sequence is designed to recover eddy current-induced signal loss (i.e., Type 1 artifact). Second, a multischeme partial-Fourier reconstruction is used to eliminate artificial signal elevation (i.e., Type 2 artifact) associated with the conventional partial-Fourier reconstruction. Third, a signal intensity correction is applied to remove artificial signal modulations due to eddy current-induced erroneous T2(∗) -weighting (i.e., Type 3 artifact). These systematic improvements will greatly increase the consistency and accuracy of DTI measurements, expanding the utility of DTI in translational applications where quantitative robustness is much needed.

  7. Brain involvement in patients with inflammatory bowel disease: a voxel-based morphometry and diffusion tensor imaging study

    International Nuclear Information System (INIS)

    Zikou, Anastasia K.; Astrakas, Loukas G.; Tzarouchi, Loukia C.; Argyropoulou, Maria I.; Kosmidou, Maria; Tsianos, Epameinondas

    2014-01-01

    To investigate structural brain changes in inflammatory bowel disease (IBD). Brain magnetic resonance imaging (MRI) was performed on 18 IBD patients (aged 45.16 ± 14.71 years) and 20 aged-matched control subjects. The imaging protocol consisted of a sagittal-FLAIR, a T1-weighted high-resolution three-dimensional spoiled gradient-echo sequence, and a multisession spin-echo echo-planar diffusion-weighted sequence. Differences between patients and controls in brain volume and diffusion indices were evaluated using the voxel-based morphometry (VBM) and tract-based spatial statistics (TBSS) methods, respectively. The presence of white-matter hyperintensities (WMHIs) was evaluated on FLAIR images. VBM revealed decreased grey matter (GM) volume in patients in the fusiform and the inferior temporal gyrus bilaterally, the right precentral gyrus, the right supplementary motor area, the right middle frontal gyrus and the left superior parietal gyrus (p < 0.05). TBSS showed decreased axial diffusivity (AD) in the right corticospinal tract and the right superior longitudinal fasciculus in patients compared with controls. A larger number of WMHIs was observed in patients (p < 0.05). Patients with IBD show an increase in WMHIs and GM atrophy, probably related to cerebral vasculitis and ischaemia. Decreased AD in major white matter tracts could be a secondary phenomenon, representing Wallerian degeneration. (orig.)

  8. Abdominal applications of 3.0-T MR imaging: comparative review versus a 1.5-T system.

    Science.gov (United States)

    Choi, Jin-Young; Kim, Myeong-Jin; Chung, Yong Eun; Kim, Ji Youn; Jones, Alun C; de Becker, Jan; van Cauteren, Marc

    2008-01-01

    With the development of dedicated receiver coils and increased gradient performance, 3.0-T magnetic resonance (MR) systems are gaining wider acceptance in clinical practice. The expected twofold increase in signal-to-noise ratio (SNR) compared with that of 1.5-T MR systems may help improve spatial resolution or increase temporal resolution when used with parallel acquisition techniques. Several issues must be considered when applying 3.0-T MR in the abdomen, including the alteration of the radiofrequency field and relaxation time, increase in energy deposition and susceptibility effects, and problems associated with motion artifacts. For the evaluation of liver lesions, higher SNR and greater resolution achieved with the 3.0-T system could translate into better detection of malignant lesions on T2-weighted images obtained with adjusted imaging parameters. For the evaluation of pancreatic and biliary diseases, high-resolution T2-weighted imaging using single-shot turbo spin-echo sequences is useful; improvement in SNR was noticeable on two-dimensional MR cholangiopancreatographic images. For the preoperative imaging of rectal cancer, a single-shot sequence is useful for dramatically decreasing imaging time while maintaining image quality. Substantial modification of examination protocols, with optimized imaging parameters and sequence designs along with ongoing development of hardware, could contribute to an increased role of the 3.0-T system for abdominal MR examinations.

  9. Parallel imaging enhanced MR colonography using a phantom model.

    LENUS (Irish Health Repository)

    Morrin, Martina M

    2008-09-01

    To compare various Array Spatial and Sensitivity Encoding Technique (ASSET)-enhanced T2W SSFSE (single shot fast spin echo) and T1-weighted (T1W) 3D SPGR (spoiled gradient recalled echo) sequences for polyp detection and image quality at MR colonography (MRC) in a phantom model. Limitations of MRC using standard 3D SPGR T1W imaging include the long breath-hold required to cover the entire colon within one acquisition and the relatively low spatial resolution due to the long acquisition time. Parallel imaging using ASSET-enhanced T2W SSFSE and 3D T1W SPGR imaging results in much shorter imaging times, which allows for increased spatial resolution.

  10. Magnetic Resonance Cholangiopancreatography: Image Quality, Ductal Morphology, and Value of Additional T2- and T1-weighted Sequences for the Assessment of Suspected Pancreatic Cancer

    International Nuclear Information System (INIS)

    Lopez Haenninen, E.; Ricke, H.; Amthauer, H.; Roettgen, R.; Boehmig, M.; Langrehr, J.; Pech, M.; Denecke, T.; Rosewicz, S.; Felix, R.

    2005-01-01

    Purpose: To assess image quality and duct morphology on magnetic resonance cholangiopancreatography (MRCP) and also the value of additional T2- and T1-weighted sequences for differentiation of benignity and malignancy in patients with suspected pancreatic tumors. Material and Methods: One-hundred-and-fourteen patients received MRCP and unenhanced and contrast material-enhanced MR imaging. MR results were analyzed independently by two blinded readers, and subsequently correlated with the results from surgery, biopsy, and follow-up. Assessment included the evaluation of image quality, duct visualization and morphology, and the differentiation of pancreatic lesion status (benign versus malignant).Results: Overall, 49 patients had benign final diagnoses, while 65 had a malignant diagnosis. Image quality of single-shot thick-slab MRCP was rated significantly better than the MIP images of multisection MRCP. With MRCP alone, the two readers' accuracy in the assessment of pancreatic lesion status was 72% (95% CI, 64% to 83%) and 69% (95% CI, 56% to 77%), respectively; with the addition of T2- and T1-weighted images the accuracy significantly improved to 89% (95% CI, 82% to 95%) and 84% (95% CI, 77% to 92%) for readers 1 and 2, respectively. Conclusion: Single-shot thick-slab MRCP and multisection MRCP provide complementary results; however, single-shot MRCP had superior image quality. Moreover, assessment of ductal morphology with MRCP alone facilitated the diagnosis of different pathologic conditions of the pancreatobiliary system in the majority of patients. However, with the addition of T2- and T1-weighted sequences the overall diagnostic accuracy was significantly improved and thus we consider that a comprehensive MR approach should comprise both MRCP techniques and parenchymal sequences

  11. High resolution x-ray lensless imaging by differential holographic encoding

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, D.; Guizar-Sicairos, M.; Wu, B.; Scherz, A.; Acremann, Y.; Tylisczcak, T.; Fischer, P.; Friedenberger, N.; Ollefs, K.; Farle, M.; Fienup, J. R.; Stohr, J.

    2009-11-02

    X-ray free electron lasers (X-FEL{sub s}) will soon offer femtosecond pulses of laterally coherent x-rays with sufficient intensity to record single-shot coherent scattering patterns for nanoscale imaging. Pulse trains created by splitand-delay techniques even open the door for cinematography on unprecedented nanometer length and femtosecond time scales. A key to real space ultrafast motion pictures is fast and reliable inversion of the recorded reciprocal space scattering patterns. Here we for the first time demonstrate in the x-ray regime the power of a novel technique for lensless high resolution imaging, previously suggested by Guizar-Sicairos and Fienup termed holography with extended reference by autocorrelation linear differential operation, HERALD0. We have achieved superior resolution over conventional x-ray Fourier transform holography (FTH) without sacrifices in SNR or significant increase in algorithmic complexity. By combining images obtained from individual sharp features on an extended reference, we further show that the resolution can be even extended beyond the reference fabrication limits. Direct comparison to iterative phase retrieval image reconstruction and images recorded with stateof- the-art zone plate microscopes is presented. Our results demonstrate the power of HERALDO as a favorable candidate for robust inversion of single-shot coherent scattering patterns.

  12. High-Resolution X-Ray Lensless Imaging by Differential Holographic Encoding

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Diling [Stanford Univ., CA (United States). Dept. of Applied Physics; SLAC National Accelerator Lab., Menlo Park, CA (United States). Stanford Inst. for Material and Energy Science; Guizar-Sicairos, Manuel [Univ. of Rochester, NY (United States). Inst. of Optics; Wu, Benny [Stanford Univ., CA (United States). Dept. of Applied Physics; SLAC National Accelerator Lab., Menlo Park, CA (United States). Stanford Inst. for Material and Energy Science; Scherz, Andreas [SLAC National Accelerator Lab., Menlo Park, CA (United States). Stanford Inst. for Material and Energy Science; Acremann, Yves [SLAC National Accelerator Lab., Menlo Park, CA (United States). Photon Ultrafast Laser Science and Engineering Inst. (PULSE); Tyliszczak, Tolek [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Advanced Light Source (ALS); Fischer, Peter [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Center for X-ray Optics; Friedenberger, Nina [Universitat Duisburg-Essen (Germany). Dept. of Physics and Center for Nanointegration Duisburg-Essen (CeNIDE); Ollefs, Katharina [Universitat Duisburg-Essen (Germany). Dept. of Physics and Center for Nanointegration Duisburg-Essen (CeNIDE); Farle, Michael [Universitat Duisburg-Essen (Germany). Dept. of Physics and Center for Nanointegration Duisburg-Essen (CeNIDE); Fienup, James R. [Univ. of Rochester, NY (United States). Inst. of Optics; Stöhr, Joachim [SLAC National Accelerator Lab., Menlo Park, CA (United States). Linac Coherent Light Source (LCLS)

    2010-07-01

    X-ray free electron lasers (X-FELs) will soon offer femtosecond pulses of laterally coherent x-rays with sufficient intensity to record single-shot coherent scattering patterns for nanoscale imaging. Pulse trains created by split and- delay techniques even open the door for cinematography on unprecedented nanometer length and femtosecond time scales. A key to real space ultrafast motion pictures is fast and reliable inversion of the recorded reciprocal space scattering patterns. Here we for the first time demonstrate in the x-ray regime the power of a novel technique for lensless high resolution imaging, previously suggested by Guizar-Sicairos and Fienup termed holography with extended reference by autocorrelation linear differential operation, HERALD0. We have achieved superior resolution over conventional x-ray Fourier transform holography (FTH) without sacrifices in SNR or significant increase in algorithmic complexity. By combining images obtained from individual sharp features on an extended reference, we further show that the resolution can be even extended beyond the reference fabrication limits. Direct comparison to iterative phase retrieval image reconstruction and images recorded with state of-the-art zone plate microscopes is presented. Our results demonstrate the power of HERALDO as a favorable candidate for robust inversion of single-shot coherent scattering patterns.

  13. Magnetic resonance imaging of placenta accreta

    Science.gov (United States)

    Varghese, Binoj; Singh, Navdeep; George, Regi A.N; Gilvaz, Sareena

    2013-01-01

    Placenta accreta (PA) is a severe pregnancy complication which occurs when the chorionic villi (CV) invade the myometrium abnormally. Optimal management requires accurate prenatal diagnosis. Ultrasonography (USG) and magnetic resonance imaging (MRI) are the modalities for prenatal diagnosis of PA, although USG remains the primary investigation of choice. MRI is a complementary technique and reserved for further characterization when USG is inconclusive or incomplete. Breath-hold T2-weighted half-Fourier rapid acquisition with relaxation enhancement (RARE) and balanced steady-state free precession imaging in the three orthogonal planes is the key MRI technique. Markedly heterogeneous placenta, thick intraplacental dark bands on half-Fourier acquisition single-shot turbo spin-echo (HASTE), and disorganized abnormal intraplacental vascularity are the cardinal MRI features of PA. MRI is less reliable in differentiating between different degrees of placental invasion, especially between accreta vera and increta. PMID:24604945

  14. Magnetic resonance imaging of placenta accreta

    Directory of Open Access Journals (Sweden)

    Binoj Varghese

    2013-01-01

    Full Text Available Placenta accreta (PA is a severe pregnancy complication which occurs when the chorionic villi (CV invade the myometrium abnormally. Optimal management requires accurate prenatal diagnosis. Ultrasonography (USG and magnetic resonance imaging (MRI are the modalities for prenatal diagnosis of PA, although USG remains the primary investigation of choice. MRI is a complementary technique and reserved for further characterization when USG is inconclusive or incomplete. Breath-hold T2-weighted half-Fourier rapid acquisition with relaxation enhancement (RARE and balanced steady-state free precession imaging in the three orthogonal planes is the key MRI technique. Markedly heterogeneous placenta, thick intraplacental dark bands on half-Fourier acquisition single-shot turbo spin-echo (HASTE, and disorganized abnormal intraplacental vascularity are the cardinal MRI features of PA. MRI is less reliable in differentiating between different degrees of placental invasion, especially between accreta vera and increta.

  15. Magnetic resonance imaging of placenta accreta

    International Nuclear Information System (INIS)

    Varghese, Binoj; Singh, Navdeep; George, Regi A.N; Gilvaz, Sareena

    2013-01-01

    Placenta accreta (PA) is a severe pregnancy complication which occurs when the chorionic villi (CV) invade the myometrium abnormally. Optimal management requires accurate prenatal diagnosis. Ultrasonography (USG) and magnetic resonance imaging (MRI) are the modalities for prenatal diagnosis of PA, although USG remains the primary investigation of choice. MRI is a complementary technique and reserved for further characterization when USG is inconclusive or incomplete. Breath-hold T2-weighted half-Fourier rapid acquisition with relaxation enhancement (RARE) and balanced steady-state free precession imaging in the three orthogonal planes is the key MRI technique. Markedly heterogeneous placenta, thick intraplacental dark bands on half-Fourier acquisition single-shot turbo spin-echo (HASTE), and disorganized abnormal intraplacental vascularity are the cardinal MRI features of PA. MRI is less reliable in differentiating between different degrees of placental invasion, especially between accreta vera and increta

  16. Initial experience of oculodynamic MRI using ultrafast T2-weighted imaging

    International Nuclear Information System (INIS)

    Tanitame, Keizo; Kaichi, Yoko; Nakamura, Yuko

    2013-01-01

    We designed cine MRI protocol using sequential static half-Fourier single-shot rapid acquisition with relaxation enhancement (RARE) images with the subjects staring at the series of targets in front of their eyes. This technique was applied to three healthy volunteers and four patients with ocular motility disorders, including blow-out fracture, globe restriction due to a large posterior staphyloma, neurogenic strabismus (convergence disorder), and intraocular adhesion. In the volunteers, smooth movements of their visual foci and extraocular muscles were observed. In the patients, the ocular movement disturbances were demonstrated. Oculodynamic MRI provides functional information in cases of diplopia. (author)

  17. The imaging of intussusception

    Energy Technology Data Exchange (ETDEWEB)

    Byrne, A.T. [Adelaide and Meath Incorporating the National Children' s Hospital, Dublin, Eire (Ireland)]. E-mail: angelabyrenx@hotmail.com; Goeghegan, T. [Adelaide and Meath Incorporating the National Children' s Hospital, Dublin, Eire (Ireland); Govender, P. [Adelaide and Meath Incorporating the National Children' s Hospital, Dublin, Eire (Ireland); Lyburn, I.D. [Department of Radiology, Frenchay Hospital, Bristol (United Kingdom); Colhoun, E. [Adelaide and Meath Incorporating the National Children' s Hospital, Dublin, Eire (Ireland); Torreggiani, W.C. [Adelaide and Meath Incorporating the National Children' s Hospital, Dublin, Eire (Ireland)]. E-mail: william.torreggiani@amnch.ie

    2005-01-01

    Intussusception is defined as the telescoping of one segment of the gastrointestinal tract into an adjacent one. It is relatively common in children and is the second most common cause of an acute abdomen in this age group. It is much less common in adults and accounts for less than 5% of cases of mechanical small bowel obstruction. Whereas the diagnosis is usually already suspected in children before imaging, it is often made unexpectedly in adults. In addition, although in children there is usually no specific underlying cause, an underlying lead point is often present in adults. Plain film radiography, barium studies and ultrasound imaging play major roles in both the diagnosis and management of this condition, and it is increasingly common for the diagnosis to be made by CT and MRI, particularly in adults. This pictorial essay reviews the imaging features that may be found in patients with bowel intussusception. As well as describing the imaging features of the more commonly used tests, we also stress the role of emerging technologies such as MRI using ultrafast half-fourier sequences with single shot turbo spin echo.

  18. The imaging of intussusception

    International Nuclear Information System (INIS)

    Byrne, A.T.; Goeghegan, T.; Govender, P.; Lyburn, I.D.; Colhoun, E.; Torreggiani, W.C.

    2005-01-01

    Intussusception is defined as the telescoping of one segment of the gastrointestinal tract into an adjacent one. It is relatively common in children and is the second most common cause of an acute abdomen in this age group. It is much less common in adults and accounts for less than 5% of cases of mechanical small bowel obstruction. Whereas the diagnosis is usually already suspected in children before imaging, it is often made unexpectedly in adults. In addition, although in children there is usually no specific underlying cause, an underlying lead point is often present in adults. Plain film radiography, barium studies and ultrasound imaging play major roles in both the diagnosis and management of this condition, and it is increasingly common for the diagnosis to be made by CT and MRI, particularly in adults. This pictorial essay reviews the imaging features that may be found in patients with bowel intussusception. As well as describing the imaging features of the more commonly used tests, we also stress the role of emerging technologies such as MRI using ultrafast half-fourier sequences with single shot turbo spin echo

  19. Diffusion MR imaging with PSIF and SPLICE. Experiences in phantom studies and the central nervous system

    International Nuclear Information System (INIS)

    Uchikoshi, Masato; Ueda, Takashi; Kaji, Yasushi

    2001-01-01

    Studies have shown that diffusion MR imaging is a reliable method for the diagnosis of central nervous system diseases, especially acute cerebral infarction. Although echo planar imaging (EPI) is a promising tool for that purpose, it is vulnerable to susceptibility artifacts that are responsible for image distortion or signal loss. Our purpose in this study was to evaluate the usefulness of diffusion MR imaging with PSIF (reversed fast imaging SSFP) and split acquisition of fast-spin-echo signals for diffusion imaging (SPLICE) in the central nervous system (CNS). First, PSIF and SPLICE were applied to the phantoms. Each phantom, including acetone, acetic acid, and water, was analyzed for apparent diffusion coefficient (ADC) based on SPLICE and for diffusion-related coefficient (DRC) based on PSIF. The ADCs based on SPLICE were 4.36±0.89 x 10 -3 mm 2 /sec, 1.25±0.04 x 10 -3 mm 2 /sec, and 2.35±0.04 x 10 -3 mm 2 /sec, and the DRCs based on PSIF were 0.353±0.25, 0.178±0.07, and 0.273±0.018 for acetone, acetic acid, and water, respectively. These calculated ADCs based on SPLICE were well correlated with known diffusion coefficients, showing a correlation coefficient of 0.995. Second, PSIF and SPLICE were applied to the CNS. The advantage of PSIF and SPLICE was that susceptibility artifacts were reduced in the images of spinal cord and brain stem. PSIF was especially useful for diffusion MR imaging in the spinal cord. The disadvantage of SPLICE was the decreased SN ratio. We conclude that PSIF or SPLICE may be helpful when EPI diffusion MR imaging is insufficient. (author)

  20. Feasibility of diffusion tensor imaging (DTI) with fibre tractography of the normal female pelvic floor

    International Nuclear Information System (INIS)

    Zijta, F.M.; Froeling, M.; Paardt, M.P. van der; Bipat, S.; Nederveen, A.J.; Stoker, J.; Lakeman, M.M.E.; Montauban van Swijndregt, A.D.; Strijkers, G.J.

    2011-01-01

    To prospectively determine the feasibility of diffusion tensor imaging (DTI) with fibre tractography as a tool for the three-dimensional (3D) visualisation of normal pelvic floor anatomy. Five young female nulliparous subjects (mean age 28 ± 3 years) underwent DTI at 3.0T. Two-dimensional diffusion-weighted axial spin-echo echo-planar (SP-EPI) pulse sequence of the pelvic floor was performed, with additional T2-TSE multiplanar sequences for anatomical reference. Fibre tractography for visualisation of predefined pelvic floor and pelvic wall muscles was performed offline by two observers, applying a consensus method. Three eigenvalues (λ1, λ2, λ3), fractional anisotropy (FA) and mean diffusivity (MD) were calculated from the fibre trajectories. In all subjects fibre tractography resulted in a satisfactory anatomical representation of the pubovisceral muscle, perineal body, anal - and urethral sphincter complex and internal obturator muscle. Mean FA values ranged from 0.23 ± 0.02 to 0.30 ± 0.04, MD values from 1.30 ± 0.08 to 1.73 ± 0.12 x 10- 3 mm 2 /s. Muscular structures in the superficial layer of the pelvic floor could not be satisfactorily identified. This study demonstrates the feasibility of visualising the complex three-dimensional pelvic floor architecture using 3T-DTI with fibre tractography. DTI of the deep female pelvic floor may provide new insights into pelvic floor disorders. (orig.)

  1. Cerebral Hemodynamics in a Healthy Population Measured by Dynamic Susceptibility Contrast MR Imaging

    International Nuclear Information System (INIS)

    Helenius, J.; Soinne, L.; Tatlisumak, T.; Kaste, M.; Aronen, H.J.

    2003-01-01

    Purpose: To establish reference data and to study age-dependency for cerebral perfusion in various regions of the brain in a healthy population. Material and Methods: Eighty healthy subjects of both genders from 22 to 85 years of age were studied with spin echo echo-planar dynamic susceptibility contrast MR imaging (DSC MRI) at 1.5 T. Cerebral blood volume (CBV), cerebral blood flow (CBF), and contrast agent mean transit time (MTT) were calculated bilaterally for 20 distinct neuro anatomic structures. Results: In gray matter, the following values were found (mean ± SD): CBV (4.6 ± 1.0 ml/100 g), CBF (94.2 ± 23.0 ml/100 g/min), and MTT (3.0 ± 0.6 s), and in white matter: CBV (1.3 ± 0.4 ml/100 g), CBF (19.6 ± 5.8 ml/100 g/min), and MTT (4.3 ± 0.7 s). The perfusion parameters did not change with age, except for a tendency to an increase in gray matter MTT and CBV. Males exhibited higher MTT and CBV than females. No hemispheric difference was found in either gender. Conclusion: Cerebral hemodynamics can be assessed with DSC MRI. Age itself seems to have only a marginal effect on cerebral perfusion in healthy population

  2. MR diffusion weighted imaging of the prostate adenocarcinoma after endocrinotherapy: preliminary results

    International Nuclear Information System (INIS)

    Chen Zhiqiang; Wang Xiaoying; Li Feiyu; Guo Xuemei; Jiang Xuexiang; Guo Yulin

    2007-01-01

    Objective: To assess the changes of the apparent diffusion coefficient (ADC) values of cancerous and noncancerous regions of prostate peripheral zone in prostate cancer patients with and without endocrinotherapy. Methods: Diffusion-weighted echo-planar imaging (EPI) were performed in 32 patients with diagnosed prostate cancer, including 18 patients who were treated with endocrinotherapy over 6 months and 14 untreated matched control patients. According to the pathological results obtained by ultrasound guided biopsy, the locations of the prostate cancerous regions were marked at one or more of the sextants. The ADC values of the bladder and the obturator internus were also measured. Results: The mean ADC values of cancerous and noncancerous regions in 14 untreated controls were (1.22±0.25) x 10 -3 , (1.59 ± 0.19) x 10 -3 mm 2 /s, respectively (t=7.03, P -3 mm 2 /s in noncancerous regions, but increased to (1.46 ± 0.30) x 10 -3 mm 2 /s in cancerous regions. There still had significant difference between the cancerous and the noncancerous regions (t=2.46, P 0.05), in bladder and the obturator internus (t=0.48, 1.64; P>0.05). Conclusion: Measurement of ADCs might be useful to evaluate the efficacy of endocrinotherapy for patients with prostate cancer. (authors)

  3. Cerebral Hemodynamics in a Healthy Population Measured by Dynamic Susceptibility Contrast MR Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Helenius, J.; Soinne, L.; Tatlisumak, T.; Kaste, M. [Helsinki Univ. Central Hospital (Finland). Dept. of Neurology; Perkioe, J.; Salonen, O.; Savolainen, S. [Helsinki Univ. Central Hospital (Finland). Dept. of Radiology; Oestergaard, L. [Aarhus Univ. Hospital (Denmark). Dept. of Neuroradiology; Carano, R.A.D. [Synarc Inc., San Francisco, CA (United States); Aronen, H.J. [Helsinki Brain Research Center (Finland). Functional Brain Imaging Unit

    2003-09-01

    Purpose: To establish reference data and to study age-dependency for cerebral perfusion in various regions of the brain in a healthy population. Material and Methods: Eighty healthy subjects of both genders from 22 to 85 years of age were studied with spin echo echo-planar dynamic susceptibility contrast MR imaging (DSC MRI) at 1.5 T. Cerebral blood volume (CBV), cerebral blood flow (CBF), and contrast agent mean transit time (MTT) were calculated bilaterally for 20 distinct neuro anatomic structures. Results: In gray matter, the following values were found (mean {+-} SD): CBV (4.6 {+-} 1.0 ml/100 g), CBF (94.2 {+-} 23.0 ml/100 g/min), and MTT (3.0 {+-} 0.6 s), and in white matter: CBV (1.3 {+-} 0.4 ml/100 g), CBF (19.6 {+-} 5.8 ml/100 g/min), and MTT (4.3 {+-} 0.7 s). The perfusion parameters did not change with age, except for a tendency to an increase in gray matter MTT and CBV. Males exhibited higher MTT and CBV than females. No hemispheric difference was found in either gender. Conclusion: Cerebral hemodynamics can be assessed with DSC MRI. Age itself seems to have only a marginal effect on cerebral perfusion in healthy population.

  4. Feasibility of diffusion tensor imaging (DTI) with fibre tractography of the normal female pelvic floor

    Energy Technology Data Exchange (ETDEWEB)

    Zijta, F.M. [University of Amsterdam, Department of Radiology, Academic Medical Center, Amsterdam (Netherlands); Onze Lieve Vrouwe Gasthuis, Department of Radiology, Amsterdam (Netherlands); Froeling, M. [University of Amsterdam, Department of Radiology, Academic Medical Center, Amsterdam (Netherlands); Eindhoven University of Technology, Biomedical NMR, Department of Biomedical Engineering, Eindhoven (Netherlands); Paardt, M.P. van der; Bipat, S.; Nederveen, A.J.; Stoker, J. [University of Amsterdam, Department of Radiology, Academic Medical Center, Amsterdam (Netherlands); Lakeman, M.M.E. [University of Amsterdam, Department of Gynaecology, Academic Medical Center, Amsterdam (Netherlands); Montauban van Swijndregt, A.D. [Onze Lieve Vrouwe Gasthuis, Department of Radiology, Amsterdam (Netherlands); Strijkers, G.J. [Eindhoven University of Technology, Biomedical NMR, Department of Biomedical Engineering, Eindhoven (Netherlands)

    2011-06-15

    To prospectively determine the feasibility of diffusion tensor imaging (DTI) with fibre tractography as a tool for the three-dimensional (3D) visualisation of normal pelvic floor anatomy. Five young female nulliparous subjects (mean age 28 {+-} 3 years) underwent DTI at 3.0T. Two-dimensional diffusion-weighted axial spin-echo echo-planar (SP-EPI) pulse sequence of the pelvic floor was performed, with additional T2-TSE multiplanar sequences for anatomical reference. Fibre tractography for visualisation of predefined pelvic floor and pelvic wall muscles was performed offline by two observers, applying a consensus method. Three eigenvalues ({lambda}1, {lambda}2, {lambda}3), fractional anisotropy (FA) and mean diffusivity (MD) were calculated from the fibre trajectories. In all subjects fibre tractography resulted in a satisfactory anatomical representation of the pubovisceral muscle, perineal body, anal - and urethral sphincter complex and internal obturator muscle. Mean FA values ranged from 0.23 {+-} 0.02 to 0.30 {+-} 0.04, MD values from 1.30 {+-} 0.08 to 1.73 {+-} 0.12 x 10-{sup 3} mm{sup 2}/s. Muscular structures in the superficial layer of the pelvic floor could not be satisfactorily identified. This study demonstrates the feasibility of visualising the complex three-dimensional pelvic floor architecture using 3T-DTI with fibre tractography. DTI of the deep female pelvic floor may provide new insights into pelvic floor disorders. (orig.)

  5. Diffusion tensor imaging in children with tuberous sclerosis complex: tract-based spatial statistics assessment of brain microstructural changes.

    Science.gov (United States)

    Zikou, Anastasia K; Xydis, Vasileios G; Astrakas, Loukas G; Nakou, Iliada; Tzarouchi, Loukia C; Tzoufi, Meropi; Argyropoulou, Maria I

    2016-07-01

    There is evidence of microstructural changes in normal-appearing white matter of patients with tuberous sclerosis complex. To evaluate major white matter tracts in children with tuberous sclerosis complex using tract-based spatial statistics diffusion tensor imaging (DTI) analysis. Eight children (mean age ± standard deviation: 8.5 ± 5.5 years) with an established diagnosis of tuberous sclerosis complex and 8 age-matched controls were studied. The imaging protocol consisted of T1-weighted high-resolution 3-D spoiled gradient-echo sequence and a spin-echo, echo-planar diffusion-weighted sequence. Differences in the diffusion indices were evaluated using tract-based spatial statistics. Tract-based spatial statistics showed increased axial diffusivity in the children with tuberous sclerosis complex in the superior and anterior corona radiata, the superior longitudinal fascicle, the inferior fronto-occipital fascicle, the uncinate fascicle and the anterior thalamic radiation. No significant differences were observed in fractional anisotropy, mean diffusivity and radial diffusivity between patients and control subjects. No difference was found in the diffusion indices between the baseline and follow-up examination in the patient group. Patients with tuberous sclerosis complex have increased axial diffusivity in major white matter tracts, probably related to reduced axonal integrity.

  6. Diffusion tensor imaging in children with tuberous sclerosis complex: tract-based spatial statistics assessment of brain microstructural changes

    International Nuclear Information System (INIS)

    Zikou, Anastasia K.; Xydis, Vasileios G.; Tzarouchi, Loukia C.; Argyropoulou, Maria I.; Astrakas, Loukas G.; Nakou, Iliada; Tzoufi, Meropi

    2016-01-01

    There is evidence of microstructural changes in normal-appearing white matter of patients with tuberous sclerosis complex. To evaluate major white matter tracts in children with tuberous sclerosis complex using tract-based spatial statistics diffusion tensor imaging (DTI) analysis. Eight children (mean age ± standard deviation: 8.5 ± 5.5 years) with an established diagnosis of tuberous sclerosis complex and 8 age-matched controls were studied. The imaging protocol consisted of T1-weighted high-resolution 3-D spoiled gradient-echo sequence and a spin-echo, echo-planar diffusion-weighted sequence. Differences in the diffusion indices were evaluated using tract-based spatial statistics. Tract-based spatial statistics showed increased axial diffusivity in the children with tuberous sclerosis complex in the superior and anterior corona radiata, the superior longitudinal fascicle, the inferior fronto-occipital fascicle, the uncinate fascicle and the anterior thalamic radiation. No significant differences were observed in fractional anisotropy, mean diffusivity and radial diffusivity between patients and control subjects. No difference was found in the diffusion indices between the baseline and follow-up examination in the patient group. Patients with tuberous sclerosis complex have increased axial diffusivity in major white matter tracts, probably related to reduced axonal integrity. (orig.)

  7. Image artifacts in concurrent transcranial magnetic stimulation (TMS) and fMRI caused by leakage currents: modeling and compensation.

    Science.gov (United States)

    Weiskopf, Nikolaus; Josephs, Oliver; Ruff, Christian C; Blankenburg, Felix; Featherstone, Eric; Thomas, Anthony; Bestmann, Sven; Driver, Jon; Deichmann, Ralf

    2009-05-01

    To characterize and eliminate a new type of image artifact in concurrent transcranial magnetic stimulation and functional MRI (TMS-fMRI) caused by small leakage currents originating from the high-voltage capacitors in the TMS stimulator system. The artifacts in echo-planar images (EPI) caused by leakage currents were characterized and quantified in numerical simulations and phantom studies with different phantom-coil geometries. A relay-diode combination was devised and inserted in the TMS circuit that shorts the leakage current. Its effectiveness for artifact reduction was assessed in a phantom scan resembling a realistic TMS-fMRI experiment. The leakage-current-induced signal changes exhibited a multipolar spatial pattern and the maxima exceeded 1% at realistic coil-cortex distances. The relay-diode combination effectively reduced the artifact to a negligible level. The leakage-current artifacts potentially obscure effects of interest or lead to false-positives. Since the artifact depends on the experimental setup and design (eg, amplitude of the leakage current, coil orientation, paradigm, EPI parameters), we recommend its assessment for each experiment. The relay-diode combination can eliminate the artifacts if necessary.

  8. High-dynamic-range imaging for cloud segmentation

    Science.gov (United States)

    Dev, Soumyabrata; Savoy, Florian M.; Lee, Yee Hui; Winkler, Stefan

    2018-04-01

    Sky-cloud images obtained from ground-based sky cameras are usually captured using a fisheye lens with a wide field of view. However, the sky exhibits a large dynamic range in terms of luminance, more than a conventional camera can capture. It is thus difficult to capture the details of an entire scene with a regular camera in a single shot. In most cases, the circumsolar region is overexposed, and the regions near the horizon are underexposed. This renders cloud segmentation for such images difficult. In this paper, we propose HDRCloudSeg - an effective method for cloud segmentation using high-dynamic-range (HDR) imaging based on multi-exposure fusion. We describe the HDR image generation process and release a new database to the community for benchmarking. Our proposed approach is the first using HDR radiance maps for cloud segmentation and achieves very good results.

  9. Assessment of coronary artery disease with nicorandil stress magnetic resonance imaging

    International Nuclear Information System (INIS)

    Kawase, Yoshio; Nichimoto, Masaki; Hato, Katsunori; Okajima, Kazue; Yoshikawa, Junichi

    2004-01-01

    Although dipyridamole and adenosine have been used as vasodilator agents, we believe they are inadequate for vasodilator perfusion magnetic resonance imaging, due to adverse effects (flushing, warmth, headaches, and arrhythmia). Nicorandil, a potassium channel opener, has been reported to increase coronary blood flow and it was associated with fewer adverse effects than adenosine or dipiridamole. We set out to investigate whether the coronary artery stenosis could be assessed by nicorandil stress perfusion magnetic resonance imaging. First-pass contrast-enhanced magnetic resonance images of the left ventricle acquired from 50 patients at rest and during intravenous administration of nicorandil using multi-slice turbo field echo with multi shot echo-planar-imaging. Coronary angiography was performed within 1 week. There was no adverse effects during nicorandil stress in any patients. The overall sensitivity and specificity of magnetic resonance imaging in identifying patients with significant stenosis of at least one coronary artery were 93.9% (31 of 33 patients) and 94.1% (16 of 17 patients), respectively. The sensitivity of magnetic resonance imaging for detecting significant stenosis in the left anterior descending artery was 87.5%; the sensitivity in the left circumflex artery was 80%; the sensitivity in the right coronary artery was 92.3%. Similar sensitivities were observed for all 3 vascular regions, indicating that all myocardial segments were visualized with similar image quality. The present study shows that nicorandil stress perfusion magnetic resonance imaging is a safe, feasible technique for assessing coronary artery stenosis severity in a totally-noninvasive manner. (authors)

  10. Spatiotemporal alignment of in utero BOLD-MRI series.

    Science.gov (United States)

    Turk, Esra Abaci; Luo, Jie; Gagoski, Borjan; Pascau, Javier; Bibbo, Carolina; Robinson, Julian N; Grant, P Ellen; Adalsteinsson, Elfar; Golland, Polina; Malpica, Norberto

    2017-08-01

    To present a method for spatiotemporal alignment of in-utero magnetic resonance imaging (MRI) time series acquired during maternal hyperoxia for enabling improved quantitative tracking of blood oxygen level-dependent (BOLD) signal changes that characterize oxygen transport through the placenta to fetal organs. The proposed pipeline for spatiotemporal alignment of images acquired with a single-shot gradient echo echo-planar imaging includes 1) signal nonuniformity correction, 2) intravolume motion correction based on nonrigid registration, 3) correction of motion and nonrigid deformations across volumes, and 4) detection of the outlier volumes to be discarded from subsequent analysis. BOLD MRI time series collected from 10 pregnant women during 3T scans were analyzed using this pipeline. To assess pipeline performance, signal fluctuations between consecutive timepoints were examined. In addition, volume overlap and distance between manual region of interest (ROI) delineations in a subset of frames and the delineations obtained through propagation of the ROIs from the reference frame were used to quantify alignment accuracy. A previously demonstrated rigid registration approach was used for comparison. The proposed pipeline improved anatomical alignment of placenta and fetal organs over the state-of-the-art rigid motion correction methods. In particular, unexpected temporal signal fluctuations during the first normoxia period were significantly decreased (P quantitative studies of placental function by improving spatiotemporal alignment across placenta and fetal organs. 1 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:403-412. © 2017 International Society for Magnetic Resonance in Medicine.

  11. Large Format Radiographic Imaging

    International Nuclear Information System (INIS)

    Rohrer, J. S.; Stewart, Lacey; Wilke, M. D.; King, N. S.; Baker A, S.; Lewis, Wilfred

    1999-01-01

    Radiographic imaging continues to be a key diagnostic in many areas at Los Alamos National Laboratory (LANL). Radiographic recording systems have taken on many form, from high repetition-rate, gated systems to film recording and storage phosphors. Some systems are designed for synchronization to an accelerator while others may be single shot or may record a frame sequence in a dynamic radiography experiment. While film recording remains a reliable standby in the radiographic community, there is growing interest in investigating electronic recording for many applications. The advantages of real time access to remote data acquisition are highly attractive. Cooled CCD camera systems are capable of providing greater sensitivity with improved signal-to-noise ratio. This paper begins with a review of performance characteristics of the Bechtel Nevada large format imaging system, a gated system capable of viewing scintillators up to 300 mm in diameter. We then examine configuration alternatives in lens coupled and fiber optically coupled electro-optical recording systems. Areas of investigation include tradeoffs between fiber optic and lens coupling, methods of image magnification, and spectral matching from scintillator to CCD camera. Key performance features discussed include field of view, resolution, sensitivity, dynamic range, and system noise characteristics

  12. Interleaved EPI diffusion imaging using SPIRiT-based reconstruction with virtual coil compression.

    Science.gov (United States)

    Dong, Zijing; Wang, Fuyixue; Ma, Xiaodong; Zhang, Zhe; Dai, Erpeng; Yuan, Chun; Guo, Hua

    2018-03-01

    To develop a novel diffusion imaging reconstruction framework based on iterative self-consistent parallel imaging reconstruction (SPIRiT) for multishot interleaved echo planar imaging (iEPI), with computation acceleration by virtual coil compression. As a general approach for autocalibrating parallel imaging, SPIRiT improves the performance of traditional generalized autocalibrating partially parallel acquisitions (GRAPPA) methods in that the formulation with self-consistency is better conditioned, suggesting SPIRiT to be a better candidate in k-space-based reconstruction. In this study, a general SPIRiT framework is adopted to incorporate both coil sensitivity and phase variation information as virtual coils and then is applied to 2D navigated iEPI diffusion imaging. To reduce the reconstruction time when using a large number of coils and shots, a novel shot-coil compression method is proposed for computation acceleration in Cartesian sampling. Simulations and in vivo experiments were conducted to evaluate the performance of the proposed method. Compared with the conventional coil compression, the shot-coil compression achieved higher compression rates with reduced errors. The simulation and in vivo experiments demonstrate that the SPIRiT-based reconstruction outperformed the existing method, realigned GRAPPA, and provided superior images with reduced artifacts. The SPIRiT-based reconstruction with virtual coil compression is a reliable method for high-resolution iEPI diffusion imaging. Magn Reson Med 79:1525-1531, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  13. Apparent diffusion coefficient vale of the brain in patients with Gaucher's disease type II and type III

    International Nuclear Information System (INIS)

    Abdel Razek, Ahmed Abdel Khalek; Abd El-Gaber, Nahed; Abdalla, Ahmed; Fathy, Abeer; Azab, Ahmed; Rahman, Ashraf Abdel

    2009-01-01

    The aim of this work is to assess the usefulness of apparent diffusion coefficient (ADC) value of the brain for diagnosis of patients with Gaucher's disease type II and type III. Prospective study was conducted upon 13 patients (nine boys and four girls aged 8 months-14 years: mean 6.1 years) with Gaucher's disease type II and III and for age-matched control group (n = 13). Diffusion-weighted magnetic resonance imaging using a single-shot echo-planar imaging with a diffusion-weighted factor b of 0, 500, and 1,000 s/mm 2 was done for all patients and volunteers. The ADC value was calculated in ten regions of the brain parenchyma and correlated with genotyping. There was significantly lower ADC value of the cortical frontal (P = 0.003), cortical temporal (P = 0.04), frontal subcortical white matter (P = 0.02), corticospinal tract (P = 0.001), cerebellum (P = 0.001), medulla (P = 0.002), and midbrain (P = 0.02) between patients and volunteers. There was significant difference in the ADC value of the frontal and temporal gray matter (P = 0.04 and 0.05, respectively) between patients with heterozygous and homozygous gene mutation. We concluded that ADC value is a new promising quantitative imaging parameter that can be used for the detection of brain abnormalities in patients with Gaucher's disease type II and type III and has a correlation with genotyping. (orig.)

  14. Whole brain white matter changes revealed by multiple diffusion metrics in multiple sclerosis: A TBSS study

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yaou, E-mail: asiaeurope80@gmail.com [Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing 100053 (China); Duan, Yunyun, E-mail: xiaoyun81.love@163.com [Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing 100053 (China); He, Yong, E-mail: yong.h.he@gmail.com [State Key Laboratory of Cognitive Neuroscience and Learning, Beijing Normal University, Beijing 100875 (China); Yu, Chunshui, E-mail: csyuster@gmail.com [Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing 100053 (China); Wang, Jun, E-mail: jun_wang@bnu.edu.cn [State Key Laboratory of Cognitive Neuroscience and Learning, Beijing Normal University, Beijing 100875 (China); Huang, Jing, E-mail: sainthj@126.com [Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing 100053 (China); Ye, Jing, E-mail: jingye.2007@yahoo.com.cn [Department of Neurology, Xuanwu Hospital, Capital Medical University, Beijing 100053 (China); Parizel, Paul M., E-mail: paul.parizel@ua.ac.be [Department of Radiology, Antwerp University Hospital and University of Antwerp, Wilrijkstraat 10, 2650 Edegem, 8 Belgium (Belgium); Li, Kuncheng, E-mail: kunchengli55@gmail.com [Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing 100053 (China); Shu, Ni, E-mail: nshu55@gmail.com [State Key Laboratory of Cognitive Neuroscience and Learning, Beijing Normal University, Beijing 100875 (China)

    2012-10-15

    Objective: To investigate whole brain white matter changes in multiple sclerosis (MS) by multiple diffusion indices, we examined patients with diffusion tensor imaging and utilized tract-based spatial statistics (TBSS) method to analyze the data. Methods: Forty-one relapsing-remitting multiple sclerosis (RRMS) patients and 41 age- and gender-matched normal controls were included in this study. Diffusion weighted images were acquired by employing a single-shot echo planar imaging sequence on a 1.5 T MR scanner. Voxel-wise analyses of multiple diffusion metrics, including fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (AD) and radial diffusivity (RD) were performed with TBSS. Results: The MS patients had significantly decreased FA (9.11%), increased MD (8.26%), AD (3.48%) and RD (13.17%) in their white matter skeletons compared with the controls. Through TBSS analyses, we found abnormal diffusion changes in widespread white matter regions in MS patients. Specifically, decreased FA, increased MD and increased RD were involved in whole-brain white matter, while several regions exhibited increased AD. Furthermore, white matter regions with significant correlations between the diffusion metrics and the clinical variables (the EDSS scores, disease durations and white matter lesion loads) in MS patients were identified. Conclusion: Widespread white matter abnormalities were observed in MS patients revealed by multiple diffusion metrics. The diffusion changes and correlations with clinical variables were mainly attributed to increased RD, implying the predominant role of RD in reflecting the subtle pathological changes in MS.

  15. Whole brain white matter changes revealed by multiple diffusion metrics in multiple sclerosis: A TBSS study

    International Nuclear Information System (INIS)

    Liu, Yaou; Duan, Yunyun; He, Yong; Yu, Chunshui; Wang, Jun; Huang, Jing; Ye, Jing; Parizel, Paul M.; Li, Kuncheng; Shu, Ni

    2012-01-01

    Objective: To investigate whole brain white matter changes in multiple sclerosis (MS) by multiple diffusion indices, we examined patients with diffusion tensor imaging and utilized tract-based spatial statistics (TBSS) method to analyze the data. Methods: Forty-one relapsing-remitting multiple sclerosis (RRMS) patients and 41 age- and gender-matched normal controls were included in this study. Diffusion weighted images were acquired by employing a single-shot echo planar imaging sequence on a 1.5 T MR scanner. Voxel-wise analyses of multiple diffusion metrics, including fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (AD) and radial diffusivity (RD) were performed with TBSS. Results: The MS patients had significantly decreased FA (9.11%), increased MD (8.26%), AD (3.48%) and RD (13.17%) in their white matter skeletons compared with the controls. Through TBSS analyses, we found abnormal diffusion changes in widespread white matter regions in MS patients. Specifically, decreased FA, increased MD and increased RD were involved in whole-brain white matter, while several regions exhibited increased AD. Furthermore, white matter regions with significant correlations between the diffusion metrics and the clinical variables (the EDSS scores, disease durations and white matter lesion loads) in MS patients were identified. Conclusion: Widespread white matter abnormalities were observed in MS patients revealed by multiple diffusion metrics. The diffusion changes and correlations with clinical variables were mainly attributed to increased RD, implying the predominant role of RD in reflecting the subtle pathological changes in MS

  16. Diffusion-weighted imaging features in spinal cord infarction

    International Nuclear Information System (INIS)

    Zhang Jingsong; Huan Yi; Sun Lijun; Chang Yingjuan; Zhao Haitao; Yang Chunmin; Zhang Guangyun

    2005-01-01

    Objective: To analyze the diffusion-weighted MR imaging findings in ischemic spinal cord lesions and discuss the value of diffusion-weighted MR imaging in differentiating diagnosis with inflammatory diseases and tumors. Methods: Six patients (2 male, 4 female) with typical sudden onset of neurological deficits caused by spinal cord ischemia were evaluated. There were no definite etiologies in all patients. DW imaging was performed within 1 to 30 days after the initial neurological symptoms using a Philips Gyroscan 1.5 TMR system. Four patients had other scans including contrast-enhanced MR imaging (CE-MRI) and/or FLAIR scans. Two of them followed up with MR images in three months. All six patients were imaged using a multi-shot, navigator-corrected, echo-planar pulse sequence, and ADC values were calculated in sagittal-oriented plane. Results: MR abnormalities were demonstrated on sagittal T 2 -weighted images with 'patch-like' or 'strip-like' hyperintensities (6/6) and cord enlargement (5/6). Axial T 2 -weighted images showed bilateral (6/6) hyperintensities. In one patient only the posterior spinal artery (PSA) territory was involved. Spinal cord was mainly affected at the cervical (2/6) and thoracolumbar (4/6) region, two of them included the conus medullaris (T10-L1). DW images showed high signals in all infarct lesions, degree of intensity depended on scanning time from ill-onset and progress of illness and whether companied with hemorrhage. In this group, except one case with closely normal ADC value due to one month course of illness, the five others ADC values of lesions calculated from ADC maps arranged from 0.23 x 10 -3 mm 2 /s to 0.47 x 10 -3 mm 2 /s [average value (0.37 ± 0.10) x 10 -3 mm 2 /s], markedly lower than normal parts [ average value (0.89 ± 0.08) x 10 -3 mm 2 /s]. There were marked difference between lesions and normal regions (t=4.71, P 2 W images. Meanwhile, lesions could be displayed much better in DW images than in T 2 W images because

  17. Multiplexing and de-multiplexing with scattering media for large field of view and multispectral imaging

    Science.gov (United States)

    Sahoo, Sujit Kumar; Tang, Dongliang; Dang, Cuong

    2018-02-01

    Large field of view multispectral imaging through scattering medium is a fundamental quest in optics community. It has gained special attention from researchers in recent years for its wide range of potential applications. However, the main bottlenecks of the current imaging systems are the requirements on specific illumination, poor image quality and limited field of view. In this work, we demonstrated a single-shot high-resolution colour-imaging through scattering media using a monochromatic camera. This novel imaging technique is enabled by the spatial, spectral decorrelation property and the optical memory effect of the scattering media. Moreover the use of deconvolution image processing further annihilate above-mentioned drawbacks arise due iterative refocusing, scanning or phase retrieval procedures.

  18. Evaluating laser-driven Bremsstrahlung radiation sources for imaging and analysis of nuclear waste packages.

    Science.gov (United States)

    Jones, Christopher P; Brenner, Ceri M; Stitt, Camilla A; Armstrong, Chris; Rusby, Dean R; Mirfayzi, Seyed R; Wilson, Lucy A; Alejo, Aarón; Ahmed, Hamad; Allott, Ric; Butler, Nicholas M H; Clarke, Robert J; Haddock, David; Hernandez-Gomez, Cristina; Higginson, Adam; Murphy, Christopher; Notley, Margaret; Paraskevoulakos, Charilaos; Jowsey, John; McKenna, Paul; Neely, David; Kar, Satya; Scott, Thomas B

    2016-11-15

    A small scale sample nuclear waste package, consisting of a 28mm diameter uranium penny encased in grout, was imaged by absorption contrast radiography using a single pulse exposure from an X-ray source driven by a high-power laser. The Vulcan laser was used to deliver a focused pulse of photons to a tantalum foil, in order to generate a bright burst of highly penetrating X-rays (with energy >500keV), with a source size of <0.5mm. BAS-TR and BAS-SR image plates were used for image capture, alongside a newly developed Thalium doped Caesium Iodide scintillator-based detector coupled to CCD chips. The uranium penny was clearly resolved to sub-mm accuracy over a 30cm(2) scan area from a single shot acquisition. In addition, neutron generation was demonstrated in situ with the X-ray beam, with a single shot, thus demonstrating the potential for multi-modal criticality testing of waste materials. This feasibility study successfully demonstrated non-destructive radiography of encapsulated, high density, nuclear material. With recent developments of high-power laser systems, to 10Hz operation, a laser-driven multi-modal beamline for waste monitoring applications is envisioned. Copyright © 2016. Published by Elsevier B.V.

  19. Image Registration to Compensate for EPI Distortion in Patients with Brain Tumors: An Evaluation of Tract-Specific Effects.

    Science.gov (United States)

    Albi, Angela; Meola, Antonio; Zhang, Fan; Kahali, Pegah; Rigolo, Laura; Tax, Chantal M W; Ciris, Pelin Aksit; Essayed, Walid I; Unadkat, Prashin; Norton, Isaiah; Rathi, Yogesh; Olubiyi, Olutayo; Golby, Alexandra J; O'Donnell, Lauren J

    2018-03-01

    Diffusion magnetic resonance imaging (dMRI) provides preoperative maps of neurosurgical patients' white matter tracts, but these maps suffer from echo-planar imaging (EPI) distortions caused by magnetic field inhomogeneities. In clinical neurosurgical planning, these distortions are generally not corrected and thus contribute to the uncertainty of fiber tracking. Multiple image processing pipelines have been proposed for image-registration-based EPI distortion correction in healthy subjects. In this article, we perform the first comparison of such pipelines in neurosurgical patient data. Five pipelines were tested in a retrospective clinical dMRI dataset of 9 patients with brain tumors. Pipelines differed in the choice of fixed and moving images and the similarity metric for image registration. Distortions were measured in two important tracts for neurosurgery, the arcuate fasciculus and corticospinal tracts. Significant differences in distortion estimates were found across processing pipelines. The most successful pipeline used dMRI baseline and T2-weighted images as inputs for distortion correction. This pipeline gave the most consistent distortion estimates across image resolutions and brain hemispheres. Quantitative results of mean tract distortions on the order of 1-2 mm are in line with other recent studies, supporting the potential need for distortion correction in neurosurgical planning. Novel results include significantly higher distortion estimates in the tumor hemisphere and greater effect of image resolution choice on results in the tumor hemisphere. Overall, this study demonstrates possible pitfalls and indicates that care should be taken when implementing EPI distortion correction in clinical settings. Copyright © 2018 by the American Society of Neuroimaging.

  20. Evaluation of the dependence of CEST-EPI measurement on repetition time, RF irradiation duty cycle and imaging flip angle for enhanced pH sensitivity

    International Nuclear Information System (INIS)

    Sun, Phillip Zhe; Lu Jie; Wu Yin; Xiao Gang; Wu Renhua

    2013-01-01

    Chemical exchange saturation transfer (CEST) is a magnetic resonance imaging (MRI) contrast mechanism that can detect dilute CEST agents and microenvironmental properties, with a host of promising applications. Experimental measurement of the CEST effect is complex, and depends on not only CEST agent concentration and exchange rate, but also experimental parameters such as RF irradiation amplitude and scheme. Although echo planar imaging (EPI) has been increasingly used for CEST MRI, the relationship between CEST effect and repetition time (TR), RF irradiation duty cycle (DC) and EPI flip angle (α) has not been fully evaluated and optimized to enhance CEST MRI sensitivity. In addition, our study evaluated gradient echo CEST-EPI by quantifying the CEST effect and its signal-to-noise ratio per unit time (SNR put ) as functions of TR, DC and α. We found that CEST effect increased with TR and DC but decreased with α. Importantly, we found that SNR put peaked at intermediate TRs of about twice the T 1 and α, at approximately 75°, and increased with RF DC. The simulation results were validated using a dual-pH creatine-gel CEST phantom. In summary, our study provides a useful framework for optimizing CEST MRI experiments. (note)

  1. Voxel-based morphometry and diffusion tensor imaging of the optic pathway in primary open-angle glaucoma: a preliminary study.

    Science.gov (United States)

    Zikou, A K; Kitsos, G; Tzarouchi, L C; Astrakas, L; Alexiou, G A; Argyropoulou, M I

    2012-01-01

    Neuropathologic studies in experimental and human glaucoma have demonstrated degenerative changes in the optic pathway. The purpose of this study was to assess the optic pathway in POAG by using VBM and DTI. Eighteen patients 57.05 ± 11.38 years of age with POAG of 8.30 ± 5.14 years' duration and 18 control subjects underwent a complete ophthalmologic examination, including quantification of the RNFLT by using Stratus OCT 3, and brain imaging. The imaging protocol consisted of a T1-weighted high-resolution 3D spoiled gradient-echo sequence and a multisection spin-echo- planar diffusion-weighted sequence. Data preprocessing and analysis were performed by using Matlab 7.0 and SPM 5. Left temporal and right nasal RNFLTs were significantly thinner than right temporal and left nasal RNFLTs. In patients, VBM revealed a significant reduction in the left visual cortex volume, the left lateral geniculate nucleus, and the intracranial part of the ONs and the chiasma. In addition, a significant decrease of FA was observed in the inferior fronto-occipital fasciculus, the longitudinal and inferior frontal fasciculi, the putamen, the caudate nucleus, the anterior and posterior thalamic radiations, and the anterior and posterior limbs of the internal capsule of the left hemisphere (P < .05). Neurodegenerative changes of the optic pathway and several brain areas associated with the visual system can be observed by using VBM and DTI in patients with POAG, suggesting that glaucoma is a complex neurologic disease.

  2. Evaluation of dual-source parallel RF excitation for diffusion-weighted whole-body MR imaging with background body signal suppression at 3.0 T.

    Science.gov (United States)

    Mürtz, Petra; Kaschner, Marius; Träber, Frank; Kukuk, Guido M; Büdenbender, Sarah M; Skowasch, Dirk; Gieseke, Jürgen; Schild, Hans H; Willinek, Winfried A

    2012-11-01

    To evaluate the use of dual-source parallel RF excitation (TX) for diffusion-weighted whole-body MRI with background body signal suppression (DWIBS) at 3.0 T. Forty consecutive patients were examined on a clinical 3.0-T MRI system using a diffusion-weighted (DW) spin-echo echo-planar imaging sequence with a combination of short TI inversion recovery and slice-selective gradient reversal fat suppression. DWIBS of the neck (n=5), thorax (n=8), abdomen (n=6) and pelvis (n=21) was performed both with TX (2:56 min) and with standard single-source RF excitation (4:37 min). The quality of DW images and reconstructed inverted maximum intensity projections was visually judged by two readers (blinded to acquisition technique). Signal homogeneity and fat suppression were scored as "improved", "equal", "worse" or "ambiguous". Moreover, the apparent diffusion coefficient (ADC) values were measured in muscles, urinary bladder, lymph nodes and lesions. By the use of TX, signal homogeneity was "improved" in 25/40 and "equal" in 15/40 cases. Fat suppression was "improved" in 17/40 and "equal" in 23/40 cases. These improvements were statistically significant (p3.0 T with respect to signal homogeneity and fat suppression, reduced scan time by approximately one-third, and did not influence the measured ADC values. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  3. Towards diffractive imaging with single pulses of FEL radiation. Dynamics within irradiatied samples and their influence on the analysis of imaging data

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Fenglin

    2010-08-15

    3D single particle coherent diffraction imaging (CDI) of bioparticles (such as proteins, macromolecules and viruses) is one of the main possible applications of the new generation of light sources: free-electron lasers (FELs), which are now available at FLASH (Hamburg, Germany) and LCLS (Stanford, U.S.A.). The extremely bright and ultrashort FEL pulses potentially enable CDI to achieve high resolution down to subnanometer length scale. However, intense FEL pulses cause serious radiation damage in bioparticles, even during single shots, which may set the resolution limits for CDI with FELs. Currently, since the signal-to-noise ratio is very low for small biological particles, direct experimental study of radiation damage in the single particle imaging is fairly difficult. Single atomic (noble gas) clusters become good objects to reveal effects of radiation damage processes on CDI with FEL radiation. This thesis studies three aspects of the radiation damage problem, which are treated in three independent chapters: (1) Molecular Dynamics simulations to quantitively describe radiation damage processes within irradiated atomic clusters during single pulses; (2) reconstruction analysis of single-shot CDI diffraction patterns of atomic clusters, which may potentially help to understand the radiation damage occurring in biological samples; and (3) testing the effects of coating water layers in CDI, which is supposed to minimize the radiation damage in irradiated bioparticles. (orig.)

  4. Clinical usefulness of diffusion-weighted imaging using low and high b-values to detect rectal cancer

    International Nuclear Information System (INIS)

    Hosonuma, Tomonori; Tozaki, Mitsuhiro; Ichiba, Noriatsu; Sakuma, Tohru; Hayashi, Daichi; Yanaga, Katsuhiko; Fukuda, Kunihiko

    2006-01-01

    The purpose of this study was to assess the potential role of diffusion-weighted imaging (DWI) using low and high b-values to detect rectal cancer. The subjects were 15 patients diagnosed endoscopically with rectal cancer (m in 1 patient, sm in 0, mp in 3, ss in 7, se in 1, a in 3) and 20 patients diagnosed endoscopically with colon cancer and no other lesions (control group). Magnetic resonance imaging was performed using a 1.5T system. DWI was performed in the axial plane using echo planar imaging sequence (repetition time/echo time 1200/66, field of view 306 X 350 mm, reconstruction matrix 156 x 256, pixel size 2.0 x 1.4 x 8.0 mm) and acquired with 2 b-values (50 and 800 s/mm 2 ). Low and high b-value DW images were analyzed visually. A lesion was positive by detection of a focal area of high signal in the rectum in high b-value images. The apparent diffusion coefficient (ADC) values of areas of high signal in high b-value images were calculated from the low and high b-value images. High b-value images enabled visualization of all 15 rectal cancers. In the control group, 13 cases were classified as negative and 7 cases as positive for rectal cancer. Sensitivity for detection of rectal cancer was 100% (15/15), and specificity was 65% (13/20). The mean ADC values in 7 patients with false-positive lesions and in 15 patients with rectal cancer were 1.374 x 10 -3 mm 2 /s (standard deviation [SD]: 0.157) and 1.194 x 10 -3 mm 2 /s (SD: 0.152), respectively (P=0.026). DWI with low and high b-values may be used to screen for rectal cancer. (author)

  5. Apparent diffusion coefficient values of the normal uterus: Interindividual variations during menstrual cycle

    International Nuclear Information System (INIS)

    Tsili, A.C.; Argyropoulou, M.I.; Tzarouchi, L.; Dalkalitsis, N.; Koliopoulos, G.; Paraskevaidis, E.; Tsampoulas, K.

    2012-01-01

    Objectives: To assess the apparent diffusion coefficient (ADC) changes of the normal uterine zones among reproductive women during the menstrual cycle. Methods: The study included 101 women of reproductive age, each with regular cycle and normal endometrium/myometrium, as proved on histopathology or MR imaging examination. Diffusion-weighted (DW) imaging was performed along the axial plane, using a single shot, multi-slice spin-echo planar diffusion pulse sequence and b-values of 0 and 800 s/mm 2 . The mean and standard deviation of the ADC values of normal endometrium/myometrium were calculated for menstrual, proliferative and secretory phase. Analysis of variance followed by the least significant difference test was used for statistical analysis. Results: The ADC values of the endometrium were different in the three phases of the menstrual cycle (menstrual phase: 1.25 ± 0.27; proliferative phase: 1.39 ± 0.20; secretory phase: 1.50 ± 0.18) (F: 9.64, p: 0.00). Statistical significant difference was observed among all groups (p 0.05). Conclusions: A wide variation of ADC values of normal endometrium and myometrium is observed during different phases of the menstrual cycle.

  6. Influence of the language dominant hemisphere on the activation region of the cerebral cortex during mastication

    International Nuclear Information System (INIS)

    Matsushima, Yasuhiko

    2005-01-01

    We used functional magnetic resonance imaging (fMRI) to examine the relationship of the activation region of the cerebral cortex during mastication with the language dominant hemisphere. Twelve healthy subjects were asked to chew a special gum 50 times on each side of the mouth, the gum changed color, becoming a deeper red, as it was chewed. The depth of red of the chewed gum was used to ascertain the habitual masticatory side. Measurements were also performed on a conventional whole body 1.5 T clinical scanner using a single shot, multislice echo-planar imaging sequence. The subjects were asked to masticate first on the right side, and then on the left side. As well, they were instructed to do a shiritori test, which is a word game. Computer analysis of the fMRI was done using statistical parametric mapping (SPM) 99 software (p<0.001, paired t-test). We found that the sensorimotor cortex activated by masticatory movements always contains language dominant hemisphere. (author)

  7. Motor association cortex activity in Parkinson's disease. A functional MRI study

    International Nuclear Information System (INIS)

    Tada, Yukiko

    1998-01-01

    The purpose of this study was to examine the activation of motor association cortex using functional magnetic resonance imaging (fMRI) in patients with Parkinson's disease (PD) and control subjects during performed hand movements. There were 26 patients with PD (12 patients with Hoehn and Yahr stage I-II, 14 patients with stage III) and 8 control subjects. Functional imaging was performed using a 1.5 tesla MRI system equipped with a single-shot, echo-planar pulse sequence. The significant signal changes were observed within the primary sensorimotor area, the supplementary motor area (SMA), and the parietal association area in both PD and control subjects. In PD subjects, the SMA was less activated than in control subjects; there were significant differences in the number of pixels activated in SMA between control and Yahr III group (p<0.01), and between Yahr I-II and Yahr III group (p<0.01). Our results demonstrated that movement related cerebral activity in the SMA is reduced in PD subjects, consistent with previously published data using other methods. It is well known from anatomical studies that one of the major cortical outputs of the basal ganglia is the SMA. This may explain the hypoactivation of the SMA in PD. Studies using fMRI provide a promising method not only for localizing cortical activation related to voluntary movements but also for investigating pathophysiology of movement disorders. (author)

  8. Hepatic ADC map as an adjunct to conventional abdominal MRI to evaluate hepatic fibrotic and clinical cirrhotic severity in biliary atresia patients

    International Nuclear Information System (INIS)

    Peng, Steven Shinn-Forng; Jeng, Yung-Ming; Hsu, Wen-Ming; Ho, Ming-Chih; Yang, Justin Cheng-Ta

    2015-01-01

    Hepatic apparent diffusion coefficient (ADC) values and ADC-related indices were correlated with the Mayo risk score for primary biliary cirrhosis (MRSPBC) and METAVIR scores of liver specimens to determine the clinical and pathological significance of diffusion-weighted magnetic resonance imaging (DWMRI). Thirty-two patients with biliary atresia (BA; mean age 461 days, range 11-4616 days) received magnetic resonance examinations from March 2009 to August 2013. A free-breathing DWMRI sequence was performed with the single-shot echo-planar imaging technique with b = 0 and 500 s/mm 2 in all 32 BA patients and 24 controls. We used the ordinal logistic regression test and Spearman rank correlation test to analyse the relationships between the MRSPBC and METAVIR fibrosis scores and right liver-to-psoas ADC ratios (LTPARs). BA patients had significantly lower LTPARs in both hepatic lobes than controls (p < 0.01). Right LTPARs, showing moderate intraobserver agreement (intraclass correlation coefficient = 0.736) and interobserver reliability (intraclass correlation coefficient = 0.659), were negatively correlated with MRSPBC and METAVIR fibrosis scores (R 2 = 0.398, p = 0.024 and R 2 = 0.628, p < 0.001, respectively). Right LTPARs may be used for long-term follow-up of cirrhosis severity in BA patients. (orig.)

  9. Distortion Correction in Fetal EPI Using Non-Rigid Registration With a Laplacian Constraint.

    Science.gov (United States)

    Kuklisova-Murgasova, Maria; Lockwood Estrin, Georgia; Nunes, Rita G; Malik, Shaihan J; Rutherford, Mary A; Rueckert, Daniel; Hajnal, Joseph V

    2018-01-01

    Geometric distortion induced by the main B0 field disrupts the consistency of fetal echo planar imaging (EPI) data, on which diffusion and functional magnetic resonance imaging is based. In this paper, we present a novel data-driven method for simultaneous motion and distortion correction of fetal EPI. A motion-corrected and reconstructed T2 weighted single shot fast spin echo (ssFSE) volume is used as a model of undistorted fetal brain anatomy. Our algorithm interleaves two registration steps: estimation of fetal motion parameters by aligning EPI slices to the model; and deformable registration of EPI slices to slices simulated from the undistorted model to estimate the distortion field. The deformable registration is regularized by a physically inspired Laplacian constraint, to model distortion induced by a source-free background B0 field. Our experiments show that distortion correction significantly improves consistency of reconstructed EPI volumes with ssFSE volumes. In addition, the estimated distortion fields are consistent with fields calculated from acquired field maps, and the Laplacian constraint is essential for estimation of plausible distortion fields. The EPI volumes reconstructed from different scans of the same subject were more consistent when the proposed method was used in comparison with EPI volumes reconstructed from data distortion corrected using a separately acquired B0 field map.

  10. T2* relaxometry of fetal brain at 1.5 Tesla using a motion tolerant method.

    Science.gov (United States)

    Vasylechko, Serge; Malamateniou, Christina; Nunes, Rita G; Fox, Matthew; Allsop, Joanna; Rutherford, Mary; Rueckert, Daniel; Hajnal, Joseph V

    2015-05-01

    The aim of this study was to determine T2* values for the fetal brain in utero and to compare them with previously reported values in preterm and term neonates. Knowledge of T2* may be useful for assessing brain development, brain abnormalities, and for optimizing functional imaging studies. Maternal respiration and unpredictable fetal motion mean that conventional multishot acquisition techniques used in adult T2* relaxometry studies are not practical. Single shot multiecho echo planar imaging was used as a rapid method for measuring fetal T2* by effectively freezing intra-slice motion. T2* determined from a sample of 24 subjects correlated negatively with gestational age with mean values of 220 ms (±45) for frontal white matter, 159 ms (±32) for thalamic gray matter, and 236 ms (±45) for occipital white matter. Fetal T2* values are higher than those previously reported for preterm neonates and decline with a consistent trend across gestational age. The data suggest that longer than usual echo times or direct T2* measurement should be considered when performing fetal fMRI to reach optimal BOLD sensitivity. © 2014 Wiley Periodicals, Inc.

  11. Longitudinal diffusion MRI for treatment response assessment: Preliminary experience using an MRI-guided tri-cobalt 60 radiotherapy system.

    Science.gov (United States)

    Yang, Yingli; Cao, Minsong; Sheng, Ke; Gao, Yu; Chen, Allen; Kamrava, Mitch; Lee, Percy; Agazaryan, Nzhde; Lamb, James; Thomas, David; Low, Daniel; Hu, Peng

    2016-03-01

    To demonstrate the preliminary feasibility of a longitudinal diffusion magnetic resonance imaging (MRI) strategy for assessing patient response to radiotherapy at 0.35 T using an MRI-guided radiotherapy system (ViewRay). Six patients (three head and neck cancer, three sarcoma) who underwent fractionated radiotherapy were enrolled in this study. A 2D multislice spin echo single-shot echo planar imaging diffusion pulse sequence was implemented on the ViewRay system and tested in phantom studies. The same pulse sequence was used to acquire longitudinal diffusion data (every 2-5 fractions) on the six patients throughout the entire course of radiotherapy. The reproducibility of the apparent diffusion coefficient (ADC) measurements was assessed using reference regions and the temporal variations of the tumor ADC values were evaluated. In diffusion phantom studies, the ADC values measured on the ViewRay system matched well with reference ADC values with ViewRay MRI. Larger patient cohort studies are warranted to correlate the longitudinal diffusion measurements to patient outcomes. Such an approach may enable response-guided adaptive radiotherapy.

  12. Hepatic ADC map as an adjunct to conventional abdominal MRI to evaluate hepatic fibrotic and clinical cirrhotic severity in biliary atresia patients

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Steven Shinn-Forng [National Taiwan University, Department of Medical Imaging, Medical College and Hospital, Taipei (China); Jeng, Yung-Ming [National Taiwan University, Department of Pathology, Medical College and Hospital, Taipei (China); Hsu, Wen-Ming; Ho, Ming-Chih [National Taiwan University, Department of Surgery, Medical College and Hospital, Taipei, Taiwan (China); Yang, Justin Cheng-Ta [National Taiwan University, Department of Medical Imaging, Medical College and Hospital, Taipei (China); National Taiwan University, Institute of Biomedical Engineering, College of Engineering and College of Medicine, Taipei (China)

    2015-10-15

    Hepatic apparent diffusion coefficient (ADC) values and ADC-related indices were correlated with the Mayo risk score for primary biliary cirrhosis (MRSPBC) and METAVIR scores of liver specimens to determine the clinical and pathological significance of diffusion-weighted magnetic resonance imaging (DWMRI). Thirty-two patients with biliary atresia (BA; mean age 461 days, range 11-4616 days) received magnetic resonance examinations from March 2009 to August 2013. A free-breathing DWMRI sequence was performed with the single-shot echo-planar imaging technique with b = 0 and 500 s/mm{sup 2} in all 32 BA patients and 24 controls. We used the ordinal logistic regression test and Spearman rank correlation test to analyse the relationships between the MRSPBC and METAVIR fibrosis scores and right liver-to-psoas ADC ratios (LTPARs). BA patients had significantly lower LTPARs in both hepatic lobes than controls (p < 0.01). Right LTPARs, showing moderate intraobserver agreement (intraclass correlation coefficient = 0.736) and interobserver reliability (intraclass correlation coefficient = 0.659), were negatively correlated with MRSPBC and METAVIR fibrosis scores (R{sup 2} = 0.398, p = 0.024 and R{sup 2} = 0.628, p < 0.001, respectively). Right LTPARs may be used for long-term follow-up of cirrhosis severity in BA patients. (orig.)

  13. Depressive Symptoms in Multiple Sclerosis from an In Vivo Study with TBSS

    Directory of Open Access Journals (Sweden)

    Yujuan Shen

    2014-01-01

    Full Text Available Clinically significant depression can impact up to 50% of patients with multiple sclerosis (MS over a course of their life time, which is associated with an increased morbidity and mortality. In our study, fifteen relapsing-remitting MS (RRMS patients and 15 age- and gender-matched normal controls were included. Diffusion tensor imaging (DTI was acquired by employing a single-shot echo planar imaging sequence on a 3.0 T MR scanner and fractional anisotropy (FA was performed with tract-based spatial statistics (TBSS approach. Finally, widespread WM and GM abnormalities were observed in RRMS patients. Moreover, the relationships between the depressive symptoms which can be measured by Hamilton depression rating scale (HAMD as well as clinical disabilities measured by the expanded disability status scale (EDSS and FA changes were listed. There was a positive relation between EDSS and the FA changes in the right inferior parietal lobule, while negative relation was located in the left anterior cingulate cortex and hippocampus. Also a positive relation between HAMD and FA changes was found in the right posterior middle cingulate gyrus, the right hippocampus, the left hypothalamus, the right precentral gyrus, and the posterior cingulate which demonstrated a link between the depressive symptoms and clinically relevant brain areas in RRMS patients.

  14. Evaluation of malignant and benign renal lesions using diffusion-weighted MRI with multiple b values

    International Nuclear Information System (INIS)

    Erbay, Gurcan; Koc, Zafer; Karadeli, Elif; Kuzgunbay, Baris; Goren, M. Resit; Bal, Nebil

    2012-01-01

    Background: Limited data are available regarding the use of diffusion-weighted (DW) magnetic resonance imaging (MRI) with multiple b values for characterization of renal lesions. Purpose: To demonstrate and compare the diagnostic performance of DW-MRI with multiple b values for renal lesion characterization. Material and Methods: Sixty-three lesions (36 malignant, 27 benign) in 60 consecutive patients (48 men, 12 women; age 60 ± 12.5 years) with solid/cystic renal lesion diagnosed after MRI were included prospectively. Single-shot echo-planar DW abdominal MRI (1.5T) was obtained using seven b values with eight apparent diffusion coefficient (ADC) maps. Contrast-to-noise ratios (CNRs), signal intensities, lesion ADCs, and lesion/normal parenchyma ADC ratios were analyzed. Receiver-operating characteristic analysis was performed. Results: The mean signal intensities of malignant lesions (at b0, 50, and 200 s/mm 2 ) were significantly lower than those of benign lesions (P 2 . ADC with all b values could better distinguish between benign and malignant lesions. A 1.35 x 10 -3 mm 2 /s threshold ADC value permitted this distinction with 85.2% sensitivity and 65.6% specificity. The lesion/normal parenchyma ADC ratio was more effective than the lesion ADC. Conclusion: In addition to the ADC value, the signal intensity curve on DW images using multiple b values could be helpful for differentiation of malignant and benign renal lesions

  15. Apparent diffusion coefficient in cervical cancer of the uterus: comparison with the normal uterine cervix

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Sato, Chiho; Ishigaki, Takeo; Kumada, Hisashi; Miura, Shunichi; Takizawa, Osamu

    2005-01-01

    A relation between apparent diffusion coefficient (ADC) values and tumor cellular density has been reported. The purpose of this study was to measure the ADC values of cervical cancers in the uterus and compare them with those of normal cervical tissues, and to test whether ADC could differentiate between normal and malignant cervical tissues in the uterus. Twelve consecutive female patients with cervical cancer of the uterus and ten female patients with other pelvic abnormalities were included in this study. ADC was measured at 1.5 T with b-factors of 0, 300 and 600 s/mm 2 using single-shot echo-planar diffusion-weighted imaging and a parallel imaging technique. The mean ADC value of cervical cancer lesions was 1.09±0.20 x 10 -3 mm 2 /s, and that of normal cervix tissue was 1.79±0.24 x 10 -3 mm 2 /s (P<0.0001). In nine patients treated by chemotherapy and/or radiation therapy, the mean ADC value of the cervical cancer lesion increased significantly after therapy (P<0.001). The present study showed, with a small number of patients, that ADC measurement has a potential ability to differentiate between normal and cancerous tissue in the uterine cervix. Further study is necessary to determine the accuracy of ADC measurement in monitoring the treatment response. (orig.)

  16. Renal zoomed EPI-DWI with spatially-selective radiofrequency excitation pulses in two dimensions

    Energy Technology Data Exchange (ETDEWEB)

    He, Yong-Lan, E-mail: ylhe_526@163.com [Department of Radiology, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing (China); Hausmann, Daniel, E-mail: daniel.hausmann@medma.uni-heidelberg.de [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim – Heidelberg University, Mannheim (Germany); Morelli, John N., E-mail: dr.john.morelli@gmail.com [St. John' s Medical Center, Tulsa, OK (United States); Attenberger, Ulrike I., E-mail: ulrike.attenberger@medma.uni-heidelberg.de [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim – Heidelberg University, Mannheim (Germany); Schoenberg, Stefan O., E-mail: stefan.schoenberg@umm.de [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim – Heidelberg University, Mannheim (Germany); Riffel, Philipp, E-mail: philipp.riffel@umm.de [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim – Heidelberg University, Mannheim (Germany)

    2016-10-15

    Highlights: • Renal zoomed diffusion-weighted imaging with spatially-selective radiofrequency excitation pulses is feasible. • z-EPI offers considerable potential for mitigating the limitations of conventional EPI techniques. • z-EPI of kidney may lead to substantial image quality improvements with reduced artifacts. - Abstract: Purpose: To evaluate the feasibility and clinical robustness of zoomed diffusion-weighted echo planar imaging (z-EPI) relative to conventional single-shot EPI (c-EPI) for DWI of the kidneys. Materials and methods: This retrospective study was approved by the institutional research ethics board. 66 patients (median age 58.5 years ± 13.4, range 23–83 years, 45 men, 21 women) undergoing 3T (Magnetom Skyra{sup ®}, Siemens Healthcare, Erlangen, Germany) using a dynamic parallel transmit array (TimTX TrueShape, Siemens Healthcare, Erlangen, Germany) for renal MRI were included in this study. Both c-EPI and z-EPI images were obtained. For z-EPI, a two-dimensional spatially-selective radiofrequency (RF) pulse was applied for echo planar imaging with the FOV reduced by a factor of 3. Two radiologists, blinded to clinical data and scan parameters evaluated the images with respect to their diagnostic confidence, overall preference, overall image quality, delineation of the kidney, spatial distortion, and image blur. Sequences were compared using a paired Wilcoxon test. ADC values for the upper pole, mid-zone, lower pole of the normal kidneys were compared between sequences as well as ADC values for renal lesions, using a paired t-test. Results: With z-EPI, the kidney was significantly better delineated with sharper boundaries, less image blur and distortion, and overall better image quality relative to c-EPI (all p < 0.001). The z-EPI technique led to greater diagnostic confidence than c-EPI (p = 0.020). z-EPI was preferred to c-EPI in 60 cases (90.9%, 60/66). No statistically significant differences in the ADC values of renal parenchyma or

  17. Renal zoomed EPI-DWI with spatially-selective radiofrequency excitation pulses in two dimensions

    International Nuclear Information System (INIS)

    He, Yong-Lan; Hausmann, Daniel; Morelli, John N.; Attenberger, Ulrike I.; Schoenberg, Stefan O.; Riffel, Philipp

    2016-01-01

    Highlights: • Renal zoomed diffusion-weighted imaging with spatially-selective radiofrequency excitation pulses is feasible. • z-EPI offers considerable potential for mitigating the limitations of conventional EPI techniques. • z-EPI of kidney may lead to substantial image quality improvements with reduced artifacts. - Abstract: Purpose: To evaluate the feasibility and clinical robustness of zoomed diffusion-weighted echo planar imaging (z-EPI) relative to conventional single-shot EPI (c-EPI) for DWI of the kidneys. Materials and methods: This retrospective study was approved by the institutional research ethics board. 66 patients (median age 58.5 years ± 13.4, range 23–83 years, 45 men, 21 women) undergoing 3T (Magnetom Skyra ® , Siemens Healthcare, Erlangen, Germany) using a dynamic parallel transmit array (TimTX TrueShape, Siemens Healthcare, Erlangen, Germany) for renal MRI were included in this study. Both c-EPI and z-EPI images were obtained. For z-EPI, a two-dimensional spatially-selective radiofrequency (RF) pulse was applied for echo planar imaging with the FOV reduced by a factor of 3. Two radiologists, blinded to clinical data and scan parameters evaluated the images with respect to their diagnostic confidence, overall preference, overall image quality, delineation of the kidney, spatial distortion, and image blur. Sequences were compared using a paired Wilcoxon test. ADC values for the upper pole, mid-zone, lower pole of the normal kidneys were compared between sequences as well as ADC values for renal lesions, using a paired t-test. Results: With z-EPI, the kidney was significantly better delineated with sharper boundaries, less image blur and distortion, and overall better image quality relative to c-EPI (all p < 0.001). The z-EPI technique led to greater diagnostic confidence than c-EPI (p = 0.020). z-EPI was preferred to c-EPI in 60 cases (90.9%, 60/66). No statistically significant differences in the ADC values of renal parenchyma or of

  18. Towards single particle imaging of human chromosomes at SACLA

    International Nuclear Information System (INIS)

    Robinson, Ian; Schwenke, Joerg; Yusuf, Mohammed; Estandarte, Ana; Zhang, Fucai; Chen, Bo; Clark, Jesse; Song, Changyong; Nam, Daewoong; Joti, Yasumasa; Tono, Kensuke; Yabashi, Makina; Ratnasari, Gina; Kaneyoshi, Kohei; Takata, Hideaki; Fukui, Kiichi

    2015-01-01

    Single particle imaging (SPI) is one of the front-page opportunities which were used to motivate the construction of the first x-ray free electron lasers (XFELs). SPI’s big advantage is that it avoids radiation damage to biological samples because the diffraction takes place in femtosecond single shots before any atomic motion can take place in the sample, hence before the onset of radiation damage. This is the ‘diffract before destruction’ theme, destruction being assured from the high x-ray doses used. This article reports our collaboration’s first attempt at SPI using the SACLA XFEL facility in June 2015. The report is limited to experience with the instrumentation and examples of data because we have not yet had time to invert them to images. (paper)

  19. Kr-PLIF for scalar imaging in supersonic flows.

    Science.gov (United States)

    Narayanaswamy, V; Burns, R; Clemens, N T

    2011-11-01

    Experiments were performed to explore the use of two-photon planar laser-induced fluorescence (PLIF) of krypton gas for applications of scalar imaging in supersonic flows. Experiments were performed in an underexpanded jet of krypton, which exhibited a wide range of conditions, from subsonic to hypersonic. Excellent signal-to-noise ratios were obtained, showing the technique is suitable for single-shot imaging. The data were used to infer the distribution of gas density and temperature by correcting the fluorescence signal for quenching effects and using isentropic relations. The centerline variation of the density and temperature from the experiments agree very well with those predicted with an empirical correlation and a CFD simulation (FLUENT). Overall, the high signal levels and quantifiable measurements indicate that Kr-PLIF could be an effective scalar marker for use in supersonic and hypersonic flow applications.

  20. Determination of cerebral perfusion using magnetic resonance imaging

    International Nuclear Information System (INIS)

    Ropele, S.

    1997-01-01

    This thesis deals with various magnetic resonance imaging methods to quantify cerebral blood flow. Special attention has been drawn to noninvasive methods. A new method based on the T1-shortening due to perfusion was developed using a multipoint inversion recovery sequence with alternating slice selective and non selective preparation. To study the influence of errors arising from partial volume effects with cerebrospinal fluid and from brain motion, numerous investigations have been performed on a clinical 1.5 Tesla scanner. In a second approach, the IVIM-method, which treats isotropic movement in the capillary network like diffusion, has been investigated. Since artifacts in phase encoding direction caused by brain motion are a common problem to most diffusion imaging techniques, a significant improvement has been achieved by the development and optimization of a single shot STEAM-sequence. This sequence proved to be less sensitive for motion artifacts, although a high signal to noise ratio has been preserved. (author)

  1. Diffusion tensor imaging--arcuate fasciculus and the importance for the neurosurgeon.

    Science.gov (United States)

    Hana, Ardian; Dooms, Georges; Boecher-Schwarz, Hans; Hertel, Frank

    2015-05-01

    Tumors in eloquent areas of the brain like Broca or Wernicke might have disastrous consequences for patients. We intended to visualize the arcuate fasciculus (AF) and to demonstrate his relation with the corticospinal tract and the visual pathway using diffusion tensor imaging (DTI). We depicted between 2012 and 2014 the AF in 71 patients. Men and women of all ages were included. Eleven patients had postoperative controls also. We used a 3DT1-sequence for the navigation. Furthermore T2- and DTI-sequences were performed. The FOV was 200 × 200 mm(2), slice thickness 2mm, and an acquisition matrix of 96 × 96 yielding nearly isotropic voxels of 2 × 2 × 2 mm. 3-Tesla-MRI was carried out strictly axial using 32 gradient directions and one b0-image. We used Echo-Planar-Imaging (EPI) and ASSET parallel imaging with an acceleration factor of 2. b-Value was 800 s/mm(2). Additional scanning time was less than 9 min. AF was portrayed in 63 patients bilaterally. In one glioblastoma patient it was impossible to visualize the left AF and in seven other patients we could not portray the right one. The lesions affected AF by disrupting or displacing the fibers. DTI might be a useful tool to portray AF. It is time-saving and can be used to preserve morbidity in patients with lesions in eloquent brain areas. It might give deeper insights of the white matter and the reorganization of AF-fibers postoperatively. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. MR diffusion weighted imaging with background signal suppression in breast cancer

    International Nuclear Information System (INIS)

    Li Ming; Zhang Bing; Zhou Zhengyang; Yu Haiping; Yuan Lei; Zhu Bin

    2009-01-01

    Objective: To explore the feasibility of echo planar imaging with short time inversion recovery (STIR-EPI) diffusion weighted imaging with background signal (DWIBS) suppression in breast cancer. Methods: The diffusion weighted imaging (DWI)with background suppression (b=800 mm 2 /s) was performed in 26 patients with breast cancer. Apparent diffusion coefficient(ADC) of all lesions were measured and compared. 3D maximum intensity projection (3D-MIP)and reverse black and white technique were used to show the lesions. DWI and DWIBS were performed and compared for the detection of breast cancer. Randomized blocks analysis of variance was used for the ADC values in different breast tissues, the ADC values in breast cancer and benign lesion were compared using t test. The paired chi square test was used for the detection rate of breast cancer in two different imaging methods. Results: Most of the breast cancers were hyperintense on DWI (b=800 mm 2 /s). The ADC value of cancer tissue was (0.93±0.25) x 10 -3 mm 2 /s, tumor necrosis was (2.06±0.17) x 10 -3 mm 2 /s, normal breast tissue was (1.92±0.23) x 10 -3 mm 2 /s and metastatic lymph node was (1.10±0.14) x 10 -3 mm 2 /s and the differences were statistically significant between two structures (P 2 =8.307, P 2 = 12.235, P -3 mm 2 /s and benign lesion (2.15±0.53) x 10 -3 mm 2 /s had significant statistical differences (t=8.626,P<0.05). Conclusion: Diffusion weighted MRI with background suppression can detect more lesions than DWI and can be potentially applied for the detection of the breast cancer combining the ADC value. (authors)

  3. Fetal diffusion tensor quantification of brainstem pathology in Chiari II malformation

    Energy Technology Data Exchange (ETDEWEB)

    Woitek, Ramona; Prayer, Daniela; Weber, Michael; Schoepf, Veronika; Furtner, Julia; Asenbaum, Ulrika; Kasprian, Gregor [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Amann, Gabriele [Medical University of Vienna, Department of Clinical Pathology, Vienna (Austria); Seidl, Rainer [Medical University of Vienna, Department of Paediatrics and Adolescent Medicine, Vienna (Austria); Bettelheim, Dieter [Medical University of Vienna, Department of Obstetrics and Gynecology, Vienna (Austria); Brugger, Peter C. [Medical University of Vienna, Center for Anatomy and Cell Biology, Vienna (Austria)

    2016-05-15

    This prenatal MRI study evaluated the potential of diffusion tensor imaging (DTI) metrics to identify changes in the midbrain of fetuses with Chiari II malformations compared to fetuses with mild ventriculomegaly, hydrocephalus and normal CNS development. Fractional anisotropy (FA) and apparent diffusion coefficient (ADC) were calculated from a region of interest (ROI) in the midbrain of 46 fetuses with normal CNS, 15 with Chiari II malformations, eight with hydrocephalus and 12 with mild ventriculomegaly. Fetuses with different diagnoses were compared group-wise after age-matching. Axial T2W-FSE sequences and single-shot echo planar DTI sequences (16 non-collinear diffusion gradient-encoding directions, b-values of 0 and 700 s/mm{sup 2}, 1.5 Tesla) were evaluated retrospectively. In Chiari II malformations, FA was significantly higher than in age-matched fetuses with a normal CNS (p =.003), while ADC was not significantly different. No differences in DTI metrics between normal controls and fetuses with hydrocephalus or vetriculomegaly were detected. DTI can detect and quantify parenchymal alterations of the fetal midbrain in Chiari II malformations. Therefore, in cases of enlarged fetal ventricles, FA of the fetal midbrain may contribute to the differentiation between Chiari II malformation and other entities. (orig.)

  4. Diffusion-weighted MR and apparent diffusion coefficient in the evaluation of severe brain injury

    International Nuclear Information System (INIS)

    Nakahara, M.; Ericson, K.; Bellander, B.M.

    2001-01-01

    Purpose: To study apparent diffusion coefficient (ADC) maps in severely brain-injured patients. Material and Methods: Four deeply comatose patients with severe brain injury were investigated with single-shot, diffusion-weighted, spin-echo echo planar imaging. The tetrahedral diffusion gradient configuration and four iterations of a set of b-values (one time of 0 mm2/s, and four times of 1000 mm2/s) were used to create isotropic ADC maps with high signal-to-noise ratio. ADC values of gray and white matter were compared among patients and 4 reference subjects. Results: one patient was diagnosed as clinically brain dead after the MR examination. The patient's ADC values of gray and white matter were significantly lower than those of 3 other brain-injured patients. In addition the ADC value of white matter was significantly lower than that of gray matter. Conclusion: The patient with fatal outcome shortly after MR examination differed significantly from other patients with severe brain injury but non-fatal outcome, with regard to ADC values in gray and white matter. This might indicate a prognostic value of ADC maps in the evaluation of traumatic brain injury

  5. Fetal diffusion tensor quantification of brainstem pathology in Chiari II malformation

    International Nuclear Information System (INIS)

    Woitek, Ramona; Prayer, Daniela; Weber, Michael; Schoepf, Veronika; Furtner, Julia; Asenbaum, Ulrika; Kasprian, Gregor; Amann, Gabriele; Seidl, Rainer; Bettelheim, Dieter; Brugger, Peter C.

    2016-01-01

    This prenatal MRI study evaluated the potential of diffusion tensor imaging (DTI) metrics to identify changes in the midbrain of fetuses with Chiari II malformations compared to fetuses with mild ventriculomegaly, hydrocephalus and normal CNS development. Fractional anisotropy (FA) and apparent diffusion coefficient (ADC) were calculated from a region of interest (ROI) in the midbrain of 46 fetuses with normal CNS, 15 with Chiari II malformations, eight with hydrocephalus and 12 with mild ventriculomegaly. Fetuses with different diagnoses were compared group-wise after age-matching. Axial T2W-FSE sequences and single-shot echo planar DTI sequences (16 non-collinear diffusion gradient-encoding directions, b-values of 0 and 700 s/mm 2 , 1.5 Tesla) were evaluated retrospectively. In Chiari II malformations, FA was significantly higher than in age-matched fetuses with a normal CNS (p =.003), while ADC was not significantly different. No differences in DTI metrics between normal controls and fetuses with hydrocephalus or vetriculomegaly were detected. DTI can detect and quantify parenchymal alterations of the fetal midbrain in Chiari II malformations. Therefore, in cases of enlarged fetal ventricles, FA of the fetal midbrain may contribute to the differentiation between Chiari II malformation and other entities. (orig.)

  6. Three-dimensional reconstruction of brain surface anatomy: technique comparison between flash and diffusion-weighted imaging

    International Nuclear Information System (INIS)

    Sun Jianzhong; Wang Zhikang; Gong Xiangyang

    2006-01-01

    Objective: To compare two methods 3D flash and diffusion-weighted images (DWI) in reconstructing the brain surface anatomy, and to evaluate their displaying ability, advantages, limitations and clinical application. Methods: Thrity normal cases were prospectively examined with 3D flash sequence and echo-planar DWI. Three-dimensional images were acquired with volume-rendering on workstation. Brain surface structures were evaluated and scored by a group of doctors. Results: Main structures of brain surface were clearly displayed on three-dimensional images based on 3D flash sequence. Average scores were all above 2.50. For images based on DWI, precentral gyrus, postcentral gyrus, superior parietal lobule, superior frontal gyrus, precentral sulcus, central sulcus, postcentral sulcus, intraparietal sulcus and superior frontal sulcus were best shown with average scores between 2.60-2.75, However, supramarginal gyrus, angular gyrus, middle frontal gyrus, inferior frontal gyrus, superior temporal gyrus, lateral sulcus, inferior frontal sulcus could not be well shown, with average scores between 1.67-2.48. Middle temporal gyrus, inferior temporal gyrus, superior temporal sulcus and inferior temporal sulcus can only get scores from 0.88 to 1.27. Scores of images based on 3D flash were much higher than that based on DWI with distinct differentiations, P values were all below 0.01. Conclusion: Three-dimensional images based on 3D flash can really display brain surface structures. It is very useful for anatomic researches. Three-dimensional reconstruction of brain surface based on DWI is a worthy technique to display brain surface anatomy, especially for frontal and parietal structures. (authors)

  7. Reproducibility of proton MR spectroscopic imaging (PEPSI): comparison of dyslexic and normal-reading children and effects of treatment on brain lactate levels during language tasks.

    Science.gov (United States)

    Richards, Todd L; Berninger, Virginia W; Aylward, Elizabeth H; Richards, Anne L; Thomson, Jennifer B; Nagy, William E; Carlisle, Joanne F; Dager, Stephen R; Abbott, Robert D

    2002-01-01

    We repeated a proton echo-planar spectroscopic imaging (PEPSI) study to test the hypothesis that children with dyslexia and good readers differ in brain lactate activation during a phonologic judgment task before but not after instructional treatment. We measured PEPSI brain lactate activation (TR/TE, 4000/144; 1.5 T) at two points 1-2 months apart during two language tasks (phonologic and lexical) and a control task (passive listening). Dyslexic participants (n = 10) and control participants (n = 8) (boys and girls aged 9-12 years) were matched in age, verbal intelligence quotients, and valid PEPSI voxels. In contrast to patients in past studies who received combined treatment, our patients were randomly assigned to either phonologic or morphologic (meaning-based) intervention between the scanning sessions. Before treatment, the patients showed significantly greater lactate elevation in the left frontal regions (including the inferior frontal gyrus) during the phonologic task. Both patients and control subjects differed significantly in the right parietal and occipital regions during both tasks. After treatment, the two groups did not significantly differ in any brain region during either task, but individuals given morphologic treatment were significantly more likely to have reduced left frontal lactate activation during the phonologic task. The previous finding of greater left frontal lactate elevation in children with dyslexia during a phonologic judgment task was replicated, and brain activation changed as a result of treatment. However, the treatment effect was due to the morphologic component rather than the phonologic component.

  8. Feasibility of diffusion-weighted magnetic resonance imaging in patients with juvenile idiopathic arthritis on 1.0-T open-bore MRI

    Energy Technology Data Exchange (ETDEWEB)

    Barendregt, Anouk M.; Nusman, Charlotte M. [University of Amsterdam, Department of Radiology, Academic Medical Center, Amsterdam (Netherlands); University of Amsterdam, Department of Pediatric Hematology, Immunology, Rheumatology and Infectious Disease, Emma Children' s Hospital AMC, Amsterdam (Netherlands); Hemke, Robert; Lavini, Cristina; Maas, Mario [University of Amsterdam, Department of Radiology, Academic Medical Center, Amsterdam (Netherlands); Amiras, Dimitri [Imperial College Healthcare NHS Trust, Radiology Department, St. Mary' s Hospital, Paddington, London (United Kingdom); Kuijpers, Taco W. [University of Amsterdam, Department of Pediatric Hematology, Immunology, Rheumatology and Infectious Disease, Emma Children' s Hospital AMC, Amsterdam (Netherlands)

    2015-12-15

    To evaluate the feasibility of non-invasive diffusion-weighted imaging (DWI) of the knee of children with juvenile idiopathic arthritis (JIA) and, further, to analyze the apparent diffusion coefficient (ADC) levels to distinguish synovium from effusion. Standard magnetic resonance imaging of the knee including post-contrast imaging was obtained in eight patients (mean age, 12 years 8 months, five females) using an open-bore magnetic resonance imaging system (1.0 T). In addition, axially acquired echo-planar DWI datasets (b-values 0, 50, and 600) were prospectively obtained and the diffusion images were post-processed into ADC{sub 50-600} maps. Two independent observers selected a region of interest (ROI) for both synovium and effusion using aligned post-contrast images as landmarks. Mann-Whitney U test was performed to compare ADC synovium and ADC effusion. DWI was successfully obtained in all patients. When data of both observers was combined, ADC synovium was lower than ADC effusion in the ROI in seven out of eight patients (median, 1.92 x 10{sup -3} mm{sup 2}/s vs. 2.40 x 10{sup -3} mm{sup 2}/s, p = 0.006, respectively). Similar results were obtained when the two observers were analyzed separately (observer 1: p = 0.006, observer 2: p = 0.04). In this pilot study, on a patient-friendly 1.0-T open-bore MRI, we demonstrated that DWI may potentially be a feasible non-invasive imaging technique in children with JIA. We could differentiate synovium from effusion in seven out of eight patients based on the ADC of synovium and effusion. However, to select synovium and effusion on DWI, post-contrast images were still a necessity. (orig.)

  9. Diffusion-we