WorldWideScience

Sample records for single-shot echo-planar imaging

  1. Single-shot echo-planar imaging of multiple sclerosis: effects of varying echo time

    International Nuclear Information System (INIS)

    Wolansky, L.J.; Chong, S.; Liu, W.C.; Kang, E.; Simpson, S.W.; Karimi, S.; Akbari, H.

    1999-01-01

    Our aim was to determine the relative merits of short and long echo times (TE) with single-shot echo-planar imaging for imaging cerebral lesions such as multiple sclerosis. We examined seven patients with clinically definite multiple sclerosis were imaged at 1.5 T. Patients were scanned with spin-echo, single-shot echo-planar imaging, using TEs of 45, 75, 105, and 135 ms. Region of interest (ROI) measurements were performed on 36 lesions at or above the level of the corona radiata. The mean image contrast (IC) was highest (231.1) for a TE of 45 ms, followed by 75 ms (218.9), 105 ms (217.9), and 135 ms (191.6). When mean contrast-to-noise ratios (C/N) were compared, the value was again highest (29.7) for TE 45 ms, followed by 75 ms (28.9), 105 ms (28.5), and 135 ms (26.3). In a lesion-by-lesion comparison, TE 45 ms had the highest IC and C/N in the largest number of cases (50 % and 47.2 %, respectively). IC and C/N for TE 45 ms were superior to those of 75 ms in 64 % and 58 %, respectively. These results support the use of relatively short TEs for single-shot echo-planar imaging in the setting of cerebral lesions such as multiple sclerosis. (orig.) (orig.)

  2. Readout-Segmented Echo-Planar Imaging in Diffusion-Weighted MR Imaging in Breast Cancer: Comparison with Single-Shot Echo-Planar Imaging in Image Quality

    International Nuclear Information System (INIS)

    Kim, Yun Ju; Kim, Sung Hun; Kang, Bong Joo; Park, Chang Suk; Kim, Hyeon Sook; Son, Yo Han; Porter, David Andrew; Song, Byung Joo

    2014-01-01

    The purpose of this study was to compare the image quality of standard single-shot echo-planar imaging (ss-EPI) and that of readout-segmented EPI (rs-EPI) in patients with breast cancer. Seventy-one patients with 74 breast cancers underwent both ss-EPI and rs-EPI. For qualitative comparison of image quality, three readers independently assessed the two sets of diffusion-weighted (DW) images. To evaluate geometric distortion, a comparison was made between lesion lengths derived from contrast enhanced MR (CE-MR) images and those obtained from the corresponding DW images. For assessment of image parameters, signal-to-noise ratio (SNR), lesion contrast, and contrast-to-noise ratio (CNR) were calculated. The rs-EPI was superior to ss-EPI in most criteria regarding the qualitative image quality. Anatomical structure distinction, delineation of the lesion, ghosting artifact, and overall image quality were significantly better in rs-EPI. Regarding the geometric distortion, lesion length on ss-EPI was significantly different from that of CE-MR, whereas there were no significant differences between CE-MR and rs-EPI. The rs-EPI was superior to ss-EPI in SNR and CNR. Readout-segmented EPI is superior to ss-EPI in the aspect of image quality in DW MR imaging of the breast

  3. Diffusion-weighted single shot echo planar imaging of colorectal cancer using a sensitivity-encoding technique

    International Nuclear Information System (INIS)

    Nasu, Katsuhiro; Kuroki, Yoshihumi; Murakami, Koji; Nawano, Shigeru; Kuroki, Seiko; Moriyama, Noriyuki

    2004-01-01

    We wanted to determine the feasibility of diffusion-weighted single shot echo planar imaging using a sensitivity encoding diffusion weighted imaging (SENSE-DWI) technique in depicting colorectal cancer. Forty-two patients with sigmoid colon cancer and rectal cancer, all proven pathologically, were examined on T2-turbo spin echo (TSE) and SENSE-DWI. No bowel preparation was performed before examination. The b-factors used in SENSE-DWI were zero and 1000 s/mm 2 . In 10 randomly selected cases, the images whose b-factors were 250 and 500 s/mm 2 were also obtained. The reduction factor of SENSE was 2.0 in all sequences. Two radiologists evaluated the obtained images from the viewpoints of tumor detectability, image distortion and misregistration of the tumors. The apparent diffusion coefficients (ADCs) of the tumors and urine in the urinary bladders in each patient were measured to evaluate the correlation between ADC and pathological classification of each tumor. All tumors were depicted hyperintensely on SENSE-DWI. Even though single shot echo planar imaging (EPI) was used, the image distortion and misregistration was quite pronounced because of simultaneous use of SENSE. On SENSE-DWI whose b-factor was 1000 s/mm 2 , the normal colon wall and feces were always hypointense and easily differentiated from the tumors. The mean ADC value of each tumor was 1.02±0.1 (x 10 -3 ) mm 2 /s. No overt correlation can be pointed out between ADC and pathological classification of each tumor. SENSE-DWI is a feasible method for depicting colorectal cancer. SENSE-DWI provides strong contrast among colorectal cancers, normal rectal wall and feces. (authors)

  4. Single-shot echo-planar imaging with Nyquist ghost compensation: interleaved dual echo with acceleration (IDEA) echo-planar imaging (EPI).

    Science.gov (United States)

    Poser, Benedikt A; Barth, Markus; Goa, Pål-Erik; Deng, Weiran; Stenger, V Andrew

    2013-01-01

    Echo planar imaging (EPI) is most commonly used for blood oxygen level-dependent fMRI, owing to its sensitivity and acquisition speed. A major problem with EPI is Nyquist (N/2) ghosting, most notably at high field. EPI data are acquired under an oscillating readout gradient and hence vulnerable to gradient imperfections such as eddy current delays and off-resonance effects, as these cause inconsistencies between odd and even k-space lines after time reversal. We propose a straightforward and pragmatic method herein termed "interleaved dual echo with acceleration (IDEA) EPI": two k-spaces (echoes) are acquired under the positive and negative readout lobes, respectively, by performing phase encoding blips only before alternate readout gradients. From these two k-spaces, two almost entirely ghost free images per shot can be constructed, without need for phase correction. The doubled echo train length can be compensated by parallel imaging and/or partial Fourier acquisition. The two k-spaces can either be complex averaged during reconstruction, which results in near-perfect cancellation of residual phase errors, or reconstructed into separate images. We demonstrate the efficacy of IDEA EPI and show phantom and in vivo images at both 3 T and 7 T. Copyright © 2012 Wiley Periodicals, Inc.

  5. Diffusion-weighted imaging of the sellar region: A comparison study of BLADE and single-shot echo planar imaging sequences

    Energy Technology Data Exchange (ETDEWEB)

    Yiping, Lu [Department of Radiology, Huashan Hospital, Fudan University, 12 Wulumuqi Rd. Middle, Shanghai 200040 (China); Hui, Liu [MR Collaboration NE Asia, Siemens Healthcare, Siemens Ltd., China, Shanghai 201318 (China); Kun, Zhou [MR PLM APPL, Siemens Shenzhen Magnetic Resonance Ltd., Shenzhen 518057 (China); Daoying, Geng, E-mail: GengdaoyingGDY@163.com [Department of Radiology, Huashan Hospital, Fudan University, 12 Wulumuqi Rd. Middle, Shanghai 200040 (China); Bo, Yin, E-mail: yinbo7@163.com [Department of Radiology, Huashan Hospital, Fudan University, 12 Wulumuqi Rd. Middle, Shanghai 200040 (China)

    2014-07-15

    Purpose: The purpose of this study is to compare BLADE diffusion-weighted imaging (DWI) with single-shot echo planar imaging (EPI) DWI on the aspects of feasibility of imaging the sellar region and image quality. Methods: A total of 3 healthy volunteers and 52 patients with suspected lesions in the sellar region were included in this prospective intra-individual study. All exams were performed at 3.0 T with a BLADE DWI sequence and a standard single-shot EP-DWI sequence. Phantom measurements were performed to measure the objective signal-to-noise ratio (SNR). Two radiologists rated the image quality according to the visualisation of the internal carotid arteries, optic chiasm, pituitary stalk, pituitary gland and lesion, and the overall image quality. One radiologist measured lesion sizes for detecting their relationship with the image score. Results: The SNR in BLADE DWI sequence showed no significant difference from the single-shot EPI sequence (P > 0.05). All of the assessed regions received higher scores in BLADE DWI images than single-shot EP-DWI.

  6. Readout-segmented echo-planar imaging improves the image quality of diffusion-weighted MR imaging in rectal cancer: Comparison with single-shot echo-planar diffusion-weighted sequences

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Chun-chao; Liu, Xi; Peng, Wan-lin; Li, Lei; Zhang, Jin-ge [Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Meng, Wen-jian; Deng, Xiang-bing [Department of Gastrointestinal Surgery, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Zuo, Pan-li [Siemens Healthcare, MR Collaborations NE Asia, 100010, Beijing (China); Li, Zhen-lin, E-mail: lzlcd01@126.com [Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China)

    2016-10-15

    Purpose: To determine whether readout-segmented echo-planar imaging (rs-EPI) diffusion-weighted imaging (DWI) can improve the image quality in patients with rectal cancer compared with single-shot echo-planar imaging (ss-EPI) DWI using 3.0 T magnetic resonance (MR) imaging. Materials and methods: This study was approved by the Institutional Review Board, and informed consent was obtained from all patients. Seventy-one patients with rectal cancer were enrolled in this study. For all patients, both rs-EPI and ss-EPI DWI were performed using a 3T MR scanner. Two radiologists independently assessed the overall image quality, lesion conspicuity, geometric distortion and distinction of anatomical structures. The signal-to-noise ratio (SNR), lesion contrast, contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC) were also measured. Comparisons of the quantitative and qualitative parameters between the two sequences were performed using the paired t-test and the Wilcoxon signed rank test. Results: The scores of overall image quality, lesion conspicuity, geometric distortion and distinction of anatomical structures of rs-EPI were all significantly higher than those of ss-EPI (all p < 0.05). The SNR and CNR were higher in rs-EPI than those in ss-EPI (all p < 0.05). There was no significant difference between ss-EPI and rs-EPI with regard to ROI size and mean ADCs of the tumour (p = 0.574 and p = 0.479, respectively), but the mean ADC of the normal tissue was higher in rs-EPI than in ss-EPI (1.73 ± 0.30 × 10{sup −3} mm{sup 2}/s vs. 1.60 ± 0.31 × 10{sup −3} mm{sup 2}/s, p = 0.001). Conclusions: DW imaging based on readout-segmented echo-planar imaging is a clinically useful technique to improve the image quality for the purpose of evaluating lesions in patients with rectal tumours.

  7. Focal liver lesion detection and characterization: Comparison of non-contrast enhanced and SPIO-enhanced diffusion-weighted single-shot spin echo echo planar and turbo spin echo T2-weighted imaging

    NARCIS (Netherlands)

    Coenegrachts, Kenneth; Matos, Celso; ter Beek, Léon; Metens, Thierry; Haspeslagh, Marc; Bipat, Shandra; Stoker, Jaap; Rigauts, Hans

    2009-01-01

    Purpose: To compare lesion conspicuity and image quality between single-shot spin echo echo planar imaging (SS SE-EPI) before, immediately and 5 min after intravenous (IV) injection of superparamagnetic iron oxide (SPIO) for detecting and characterizing focal liver lesions (FLLs). Materials and

  8. Changes in susceptibility signs on serial T2*-weighted single-shot echo-planar gradient-echo images in acute embolic infarction: comparison with recanalization status on 3D time-of-flight magnetic resonance angiography

    International Nuclear Information System (INIS)

    Shinohara, Yuki; Kinoshita, Toshibumi; Kinoshita, Fumiko

    2012-01-01

    The present study compares changes in susceptibility signs on follow-up single-shot echo-planar gradient-echo T2*-weighted images (GRE-EPI) with vascular status on follow-up magnetic resonance angiography (MRA) in acute embolic infarction. Twenty consecutive patients with acute embolic infarction repeatedly underwent MR imaging including GRE-EPI and MRA using a 1.5-T MR superconducting system. All patients underwent initial MR examination within 24 h of onset and follow-up MR imaging within 1 month after onset. Changes in susceptibility signs on follow-up GRE-EPI were compatible with vascular status on follow-up MRA in 19 of the 20 patients. Susceptibility signs disappeared with complete recanalization in 13 patients, migrated with partial recanalization in 3, did not change together with the absence of recanalization in 2, and became extended together with the absence of recanalization in 1. Cerebral hemorrhage obscured susceptibility signs in the one remaining patient. Susceptibility signs on follow-up GRE-EPI can reflect changes in an acute embolus, such as recanalization or migration, in this study. Serial GRE-EPI in acute embolism complements the diagnostic certainty of MRA by directly detecting an embolus as a susceptibility sign. (orig.)

  9. Single-shot echo-planar MR sequences in the diagnosis of intracranial infectious diseases

    International Nuclear Information System (INIS)

    Tsuchiya, Kazuhiro; Katase, Shichiro; Yoshino, Ayako; Yamakami, Norio; Hachiya, Junichi

    1998-01-01

    The purpose of this study was to present our preliminary experience in the application of echo-planar-imaging (EPI) MR sequences for the diagnosis of intracranial infectious diseases and to assess the value of these sequences. We reviewed single-shot EPI MR images obtained at 1.5 T in 17 patients and compared these images with conventional or fast spin-echo (SE) or fluid attenuated inversion-recovery (FLAIR) images. The clinical diagnoses for the 17 patients were meningitis (2 patients), encephalitis or meningoencephalitis (7 patients), brain abscess (5 patients), epidural empyema (2 patients) and Creutzfeldt-Jakob disease (1 patient). We obtained EPI-T 2 -weighted (T 2 W) images in 8 patients, EPI-FLAIR images in 13 patients and EPI-diffusion-weighted (DW) images in 14 patients. Among the 8 patients for whom EPI-T 2 W imaging was performed, EPI-T 2 W imaging yielded superior results compared with SE-T 2 W imaging in 3 patients as a consequence of patient motion and equal results compared with SE-T 2 W imaging in 5 patients. Among the 13 patients for whom EPI-FLAIR imaging was performed, the EPI-FLAIR images were superior to conventional FLAIR images in 3 unstable patients. In the remaining 10 patients for whom EPI-FLAIR imaging was performed, EPI-FLAIR images were equivalent or inferior to conventional FLAIR images. In 6 patients with encephalitis or meningoencephalitis, the encephalitic lesions showed hyperintensity in EPI-DW images to a greater extent than in images obtained with the other techniques. In 3 patients, EPI-DW images also demonstrated hyperintensity for the contents of abscesses or areas of empyema that was not seen with the other imaging techniques. The value of EPI-T 2 W and EPI-FLAIR imaging is limited in uncooperative patients. EPI-DW imaging was found to be of value for the evaluation of several intracranial infectious diseases. (author)

  10. Single-shot echo-planar MR sequences in the diagnosis of intracranial infectious diseases

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiya, Kazuhiro; Katase, Shichiro; Yoshino, Ayako; Yamakami, Norio; Hachiya, Junichi [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine

    1998-06-01

    The purpose of this study was to present our preliminary experience in the application of echo-planar-imaging (EPI) MR sequences for the diagnosis of intracranial infectious diseases and to assess the value of these sequences. We reviewed single-shot EPI MR images obtained at 1.5 T in 17 patients and compared these images with conventional or fast spin-echo (SE) or fluid attenuated inversion-recovery (FLAIR) images. The clinical diagnoses for the 17 patients were meningitis (2 patients), encephalitis or meningoencephalitis (7 patients), brain abscess (5 patients), epidural empyema (2 patients) and Creutzfeldt-Jakob disease (1 patient). We obtained EPI-T{sub 2}-weighted (T{sub 2}W) images in 8 patients, EPI-FLAIR images in 13 patients and EPI-diffusion-weighted (DW) images in 14 patients. Among the 8 patients for whom EPI-T{sub 2}W imaging was performed, EPI-T{sub 2}W imaging yielded superior results compared with SE-T{sub 2}W imaging in 3 patients as a consequence of patient motion and equal results compared with SE-T{sub 2}W imaging in 5 patients. Among the 13 patients for whom EPI-FLAIR imaging was performed, the EPI-FLAIR images were superior to conventional FLAIR images in 3 unstable patients. In the remaining 10 patients for whom EPI-FLAIR imaging was performed, EPI-FLAIR images were equivalent or inferior to conventional FLAIR images. In 6 patients with encephalitis or meningoencephalitis, the encephalitic lesions showed hyperintensity in EPI-DW images to a greater extent than in images obtained with the other techniques. In 3 patients, EPI-DW images also demonstrated hyperintensity for the contents of abscesses or areas of empyema that was not seen with the other imaging techniques. The value of EPI-T{sub 2}W and EPI-FLAIR imaging is limited in uncooperative patients. EPI-DW imaging was found to be of value for the evaluation of several intracranial infectious diseases. (author)

  11. Single-Shot Echo-Planar Diffusion-Weighted MR Imaging at 3T and 1.5T for Differentiation of Benign Vertebral Fracture Edema and Tumor Infiltration

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hee Jin; Lee, So Yeon; Rho, Myung Ho; Chung, Eun Chul; Kim, Mi Sung; Kwon, Heon Ju; Youn, In Young [Department of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul 03181 (Korea, Republic of)

    2016-11-01

    To compare the apparent diffusion coefficient (ADC) value using single-shot echo-planar imaging sequences at 3T and 1.5T for differentiation of benign fracture edema and tumor infiltration of the vertebral body. A total of 46 spinal examinations were included in the 1.5T MRI group, and a total of 40 spinal examinations were included in the 3T MRI group. The ADC values of the lesion were measured and calculated. The diagnostic performance of the conventional MR image containing sagittal T2-weighted fat saturated image and each diffusion weighted image (DWI) with an ADC value with different b values were evaluated. The mean ADC value of the benign lesions was higher than that of the malignant lesions on 1.5T and 3T (p < 0.05). The sensitivity of the diagnostic performance was higher with an additional DWI in both 1.5T and 3T, but the sensitivities were similar with the addition of b values of 400 and 1000. The specificities of the diagnostic performances did not show significant differences (p value > 0.05). The diagnostic accuracies were higher when either of the DWIs (b values of 400 and 1000) was added to routine MR image for 1.5T and 3T. Statistical differences between 1.5T and 3T or between b values of 400 and 1000 were not seen. The ADC values of the benign lesions were significantly higher than those of the malignant lesions on 1.5T and 3T. There was no statistically significant difference in the diagnostic performances when either of the DWIs (b values of 400 and 1000) was added to the routine MR image for 1.5T and 3T.

  12. Initial experience in perfusion MR imaging of intracranial major artery occlusion with echo-planar technique

    International Nuclear Information System (INIS)

    Tsuchiya, Kazuhiro; Mizutani, Yoshiyuki; Inaoka, Sayuki; Hachiya, Junichi

    1997-01-01

    The purpose of this study was to evaluate the usefulness of perfusion MR imaging using a single-shot echo-planar technique in occlusion of intracranial main arteries. Our patient group consisted of 16 patients with internal carotid artery occlusion (n=9), Moyamoya disease (n=4), and middle cerebral artery occlusion (n=3). We performed the echo-planar perfusion studies with a 1.5-T unit using a free-induction-decay-type echo-planar sequence. With a bolus injection of Gd-DTPA, 30 consecutive scans were obtained at 10 sections every 2 seconds. The data were analyzed in three ways: a time-intensity curves in the territory of the involved artery (n=16); semiquantitative flow map of each section representing signal changes due to passage of Gd-DTPA (n=15); and serial images at a selected section (n=7). The time intensity curves were abnormal in 13 patients. The peak of signal drop was delayed in all of them. Flow maps showed focal flow abnormalities in 11 patients, but they were apparently normal in 4 patients probably due to collateral flow. In serial images, delay in appearance and/or disappearance of Gd-DTPA was noted in 6 patients. In patients with occlusion of intracranial main arteries, MR single-shot echo-planar technique is of clinical use because it can provide information about hemodynamic changes in a short examination time, in multiple sections, and with good temporal resolution. (author)

  13. High-resolution three-dimensional diffusion-weighted imaging of middle ear cholesteatoma at 3.0 T MRI: Usefulness of 3D turbo field-echo with diffusion-sensitized driven-equilibrium preparation (TFE–DSDE) compared to single-shot echo-planar imaging

    International Nuclear Information System (INIS)

    Yamashita, Koji; Yoshiura, Takashi; Hiwatashi, Akio; Obara, Makoto; Togao, Osamu; Matsumoto, Nozomu; Kikuchi, Kazufumi; Honda, Hiroshi

    2013-01-01

    Objective: To prospectively evaluate the usefulness of a newly developed high-resolution three-dimensional diffusion-weighted imaging method, turbo field-echo with diffusion-sensitized driven-equilibrium (TFE–DSDE) in diagnosing middle-ear cholesteatoma by comparing it to conventional single-shot echo-planar diffusion-weighted imaging (SS-EP DWI). Materials and methods: Institutional review board approval and informed consent from all participants were obtained. We studied 30 patients with preoperatively suspected acquired cholesteatoma. Each patient underwent an MR examination including both SS-EP DWI and DSDE-TFE using a 3.0 T MR scanner. Images of the 30 patients (60 temporal bones including 30 with and 30 without cholesteatoma) were reviewed by two independent neuroradiologists. The confidence level for the presence of cholesteatoma was graded on a scale of 0–2 (0 = definite absence, 1 = equivocal, 2 = definite presence). Interobserver agreement as well as sensitivity, specificity, and accuracy for detection were assessed for the two reviewers. Results: Excellent interobserver agreement was shown for TFE–DSDE (κ = 0.821) whereas fair agreement was obtained for SS-EP DWI (κ = 0.416). TFE–DSDE was associated with significantly higher sensitivity (83.3%) and accuracy (90.0%) compared to SS-EP DWI (sensitivity = 35.0%, accuracy = 66.7%; p < 0.05). No significant difference was found in specificity (96.7% for TFE–DSDE, 98.3% for SS-EP DWI) Conclusion: With increased spatial resolution and reduced susceptibility artifacts, TFE–DSDE improves the accuracy in diagnosing acquired middle ear cholesteatomas compared to SS-EP DWI

  14. Echo Planar Diffusion-Weighted Imaging: Possibilities and Considerations with 12- and 32-Channel Head Coils

    Directory of Open Access Journals (Sweden)

    John N Morelli

    2012-01-01

    Full Text Available Interest in clinical brain magnetic resonance imaging using 32-channel head coils for signal reception continues to increase. The present investigation assesses possibilities for improving diffusion-weighted image quality using a 32-channel in comparison to a conventional 12-channel coil. The utility of single-shot (ss and an approach to readout-segmented (rs echo planar imaging (EPI are examined using both head coils. Substantial image quality improvements are found with rs-EPI. Imaging with a 32-channel head coil allows for implementation of greater parallel imaging acceleration factors or acquisition of scans at a higher resolution. Specifically, higher resolution imaging with rs-EPI can be achieved by increasing the number of readout segments without increasing echo-spacing or echo time to the degree necessary with ss-EPI - a factor resulting in increased susceptibility artifact and reduced signal-to-noise with the latter.

  15. Implementation and assessment of diffusion-weighted partial Fourier readout-segmented echo-planar imaging.

    Science.gov (United States)

    Frost, Robert; Porter, David A; Miller, Karla L; Jezzard, Peter

    2012-08-01

    Single-shot echo-planar imaging has been used widely in diffusion magnetic resonance imaging due to the difficulties in correcting motion-induced phase corruption in multishot data. Readout-segmented EPI has addressed the multishot problem by introducing a two-dimensional nonlinear navigator correction with online reacquisition of uncorrectable data to enable acquisition of high-resolution diffusion data with reduced susceptibility artifact and T*(2) blurring. The primary shortcoming of readout-segmented EPI in its current form is its long acquisition time (longer than similar resolution single-shot echo-planar imaging protocols by approximately the number of readout segments), which limits the number of diffusion directions. By omitting readout segments at one side of k-space and using partial Fourier reconstruction, readout-segmented EPI imaging times could be reduced. In this study, the effects of homodyne and projection onto convex sets reconstructions on estimates of the fractional anisotropy, mean diffusivity, and diffusion orientation in fiber tracts and raw T(2)- and trace-weighted signal are compared, along with signal-to-noise ratio results. It is found that projections onto convex sets reconstruction with 3/5 segments in a 2 mm isotropic diffusion tensor image acquisition and 9/13 segments in a 0.9 × 0.9 × 4.0 mm(3) diffusion-weighted image acquisition provide good fidelity relative to the full k-space parameters. This allows application of readout-segmented EPI to tractography studies, and clinical stroke and oncology protocols. Copyright © 2011 Wiley-Liss, Inc.

  16. MR elastography of liver fibrosis: preliminary results comparing spin-echo and echo-planar imaging

    Energy Technology Data Exchange (ETDEWEB)

    Huwart, Laurent; Salameh, Najat; Peeters, Frank; Beers, Bernard E. van [Universite Catholique de Louvain, St-Luc University Hospital, Diagnostic Radiology Unit, Brussels (Belgium); Beek, Leon ter [Philips Medical Systems, Best (Netherlands); Vicaut, Eric [Universite Paris Diderot, Hopital Lariboisiere, Paris (France); Sinkus, Ralph [Universite Paris Diderot, Laboratoire Ondes et Acoustique, Ecole Superieure de Physique et de Chimie Industrielles de la Ville de Paris, Paris (France)

    2008-11-15

    The purpose of this study was to prospectively compare the performance of magnetic resonance (MR) elastography using echo-planar and spin-echo imaging for staging of hepatic fibrosis. Twenty-four patients who had liver biopsy for suspicion of chronic liver disease had MR elastography performed with both spin-echo and echo-planar sequences. At histology, the fibrosis stage was assessed according to METAVIR. The data acquisition time was about 20 min using spin-echo, and only 2 min using echo-planar imaging. The hepatic signal-to-noise ratios were similar on both images (22.51 {+-} 5.37 for spin-echo versus 21.02 {+-} 4.76 for echo-planar, p = 0.33). The elasticity measurements and the fibrosis stages were strongly correlated. The Spearman correlation coefficients were r = 0.91 (p < 0.01) with spin-echo and r = 0.84 (p < 0.01) with echo-planar sequences. These correlation coefficients did not differ significantly (p = 0.17). A strong correlation was also observed between spin-echo and echo-planar elasticity (r = 0.83, p < 0.001), without systematic bias. The results of our study showed that echo-planar imaging substantially decreased the data acquisition time of MR elastography, while maintaining the image quality and diagnostic performance for staging of liver fibrosis. This suggests that echo-planar MR elastography could replace spin-echo MR elastography in clinical practice. (orig.)

  17. Multishot echo-planar MREIT for fast imaging of conductivity, current density, and electric field distributions.

    Science.gov (United States)

    Chauhan, Munish; Vidya Shankar, Rohini; Ashok Kumar, Neeta; Kodibagkar, Vikram D; Sadleir, Rosalind

    2018-01-01

    Magnetic resonance electrical impedance tomography (MREIT) sequences typically use conventional spin or gradient echo-based acquisition methods for reconstruction of conductivity and current density maps. Use of MREIT in functional and electroporation studies requires higher temporal resolution and faster sequences. Here, single and multishot echo planar imaging (EPI) based MREIT sequences were evaluated to see whether high-quality MREIT phase data could be obtained for rapid reconstruction of current density, conductivity, and electric fields. A gel phantom with an insulating inclusion was used as a test object. Ghost artifact, geometric distortion, and MREIT correction algorithms were applied to the data. The EPI-MREIT-derived phase-projected current density and conductivity images were compared with simulations and spin-echo images as a function of EPI shot number. Good agreement among measures in simulated, spin echo, and EPI data was achieved. Current density errors were stable and below 9% as the shot number decreased from 64 to 2, but increased for single-shot images. Conductivity reconstruction relative contrast ratios were stable as the shot number decreased. The derived electric fields also agreed with the simulated data. The EPI methods can be combined successfully with MREIT reconstruction algorithms to achieve fast imaging of current density, conductivity, and electric field. Magn Reson Med 79:71-82, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  18. Clinical evaluation of single-shot and readout-segmented diffusion-weighted imaging in stroke patients at 3 T

    International Nuclear Information System (INIS)

    Morelli, John; Porter, David; Ai, Fei

    2013-01-01

    Background: Diffusion-weighted imaging (DWI) magnetic resonance imaging (MRI) is most commonly performed utilizing a single-shot echo-planar imaging technique (ss-EPI). Susceptibility artifact and image blur are severe when this sequence is utilized at 3 T. Purpose: To evaluate a readout-segmented approach to DWI MR in comparison with single-shot echo planar imaging for brain MRI. Material and Methods: Eleven healthy volunteers and 14 patients with acute and early subacute infarctions underwent DWI MR examinations at 1.5 and 3T with ss-EPI and readout-segmented echo-planar (rs-EPI) DWI at equal nominal spatial resolutions. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) calculations were made, and two blinded readers ranked the scans in terms of high signal intensity bulk susceptibility artifact, spatial distortions, image blur, overall preference, and motion artifact. Results: SNR and CNR were greatest with rs-EPI (8.1 ± 0.2 SNR vs. 6.0 ± 0.2; P -4 at 3T). Spatial distortions were greater with single-shot (0.23 ± 0.03 at 3T; P <0.001) than with rs-EPI (0.12 ± 0.02 at 3T). Combined with blur and artifact reduction, this resulted in a qualitative preference for the readout-segmented scans overall. Conclusion: Substantial image quality improvements are possible with readout-segmented vs. single-shot EPI - the current clinical standard for DWI - regardless of field strength (1.5 or 3 T). This results in improved image quality secondary to greater real spatial resolution and reduced artifacts from susceptibility in MR imaging of the brain

  19. Breath-hold MR cholangiopancreatography with three-dimensional, segmented, echo-planar imaging and volume rendering

    NARCIS (Netherlands)

    P.A. Wielopolski (Piotr); J. Gaa; D.R. Wielopolski; M. Oudkerk (Matthijs)

    1999-01-01

    textabstractEnd-expiration, 21-second breath-hold, three-dimensional magnetic resonance (MR) cholangiopancreatography (MRCP) was developed with segmented echo-planar imaging. In 15 healthy subjects and 14 randomly selected patients undergoing liver studies,

  20. Echo planar imaging of normal and abnormal connections of the heart and great arteries

    Energy Technology Data Exchange (ETDEWEB)

    Chrispin, A.; Small, P.; Rutter, N.; Coupland, R.E.; Doyle, M.; Chapman, B.; Coxon, R.; Guilfoyle, D.; Cawley, M.; Mansfield, P.

    1986-05-01

    Echo planar imaging (EPI) is that form of magnetic resonance imaging which provides very short image acquisition times. EPI also provides very rapid sequential imaging. The EPI method is ideal for imaging the heart and thoracic content because images are devoid of cardio-respiratory motion artefact. Previously an analysis of transectional images has been presented. This paper is concerned with the study of the heart by the use of EPI contsructions in the sagittal and coronal planes. Defining connections between ventricle and great artery is of cardinal importance in paediatric cardiology. EPI contsructions in the normal heart, transposition, truncus arteriosus and right heart hypoplasia are presented and discussed.

  1. Echo planar imaging of normal and abnormal connections of the heart and great arteries

    International Nuclear Information System (INIS)

    Chrispin, A.; Small, P.; Rutter, N.; Coupland, R.E.; Doyle, M.; Chapman, B.; Coxon, R.; Guilfoyle, D.; Cawley, M.; Mansfield, P.

    1986-01-01

    Echo planar imaging (EPI) is that form of magnetic resonance imaging which provides very short image acquisition times. EPI also provides very rapid sequential imaging. The EPI method is ideal for imaging the heart and thoracic content because images are devoid of cardio-respiratory motion artefact. Previously an analysis of transectional images has been presented. This paper is concerned with the study of the heart by the use of EPI contsructions in the sagittal and coronal planes. Defining connections between ventricle and great artery is of cardinal importance in paediatric cardiology. EPI contsructions in the normal heart, transposition, truncus arteriosus and right heart hypoplasia are presented and discussed. (orig.)

  2. Comparison of Fourier transform and continuous wavelet transform to study echo-planar imaging flow maps

    International Nuclear Information System (INIS)

    Rodriguez G, A.; Bowtell, R.; Mansfield, P.

    1998-01-01

    Velocity maps were studied combining Doyle and Mansfield method (1986) with each of the following transforms: Fourier, window Fourier and wavelet (Mexican hat). Continuous wavelet transform was compared against the two Fourier transform to determine which technique is best suited to study blood maps generated by Half Fourier Echo-Planar Imaging. Coefficient images were calculated and plots of the pixel intensity variation are presented. Finally, contour maps are shown to visualize the behavior of the blood flow in the cardiac chambers for the wavelet technique. (Author)

  3. Comparison of Fourier transform and continuous wavelet transform to study echo-planar imaging flow maps

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez G, A.; Bowtell, R.; Mansfield, P. [Area de Procesamiento Digital de Senales e Imagenes Biomedicas. Universidad Autonoma Metropolitana Iztapalapa. Mexico D.F. 09340 Mexico (Mexico)

    1998-12-31

    Velocity maps were studied combining Doyle and Mansfield method (1986) with each of the following transforms: Fourier, window Fourier and wavelet (Mexican hat). Continuous wavelet transform was compared against the two Fourier transform to determine which technique is best suited to study blood maps generated by Half Fourier Echo-Planar Imaging. Coefficient images were calculated and plots of the pixel intensity variation are presented. Finally, contour maps are shown to visualize the behavior of the blood flow in the cardiac chambers for the wavelet technique. (Author)

  4. Whole-brain analysis of amyotrophic lateral sclerosis by using echo-planar spectroscopic imaging.

    Science.gov (United States)

    Verma, Gaurav; Woo, John H; Chawla, Sanjeev; Wang, Sumei; Sheriff, Sulaiman; Elman, Lauren B; McCluskey, Leo F; Grossman, Murray; Melhem, Elias R; Maudsley, Andrew A; Poptani, Harish

    2013-06-01

    To detect regional metabolic differences in amyotrophic lateral sclerosis (ALS) with whole-brain echo-planar spectroscopic imaging. Sixteen patients with ALS (nine men, seven women; mean age, 56.6 years), five persons suspected of having ALS (four men, one woman; mean age, 62.6 years), and 10 healthy control subjects (five men, five women; mean age, 56.1 years) underwent echo-planar spectroscopic imaging after providing informed consent. The study was approved by the institutional review board and complied with HIPAA. Data were analyzed with the Metabolic Imaging and Data Analysis System software, and processed metabolite maps were coregistered and normalized to a standard brain template. Metabolite maps of creatine (Cr), choline (Cho), and N-acetylaspartate (NAA) were segmented into 81 regions with Automated Anatomical Labeling software to measure metabolic changes throughout the brains of patients with ALS. Statistical analysis involved an unpaired, uncorrected, two-sided Student t test. The NAA/Cho ratio across six regions was significantly lower by a mean of 23% (P ≤ .01) in patients with ALS than in control subjects. These regions included the caudate, lingual gyrus, supramarginal gyrus, and right and left superior and right inferior occipital lobes. The NAA/Cr ratio was significantly lower (P ≤ .01) in eight regions in the patient group, by a mean of 16%. These included the caudate, cuneus, frontal inferior operculum, Heschl gyrus, precentral gyrus, rolandic operculum, and superior and inferior occipital lobes. The Cho/Cr ratio did not significantly differ in any region between patient and control groups. Whole-brain echo-planar spectroscopic imaging permits detection of regional metabolic abnormalities in ALS, including not only the motor cortex but also several other regions implicated in ALS pathophysiologic findings.

  5. Diffusion-weighted multiple shot echo planar imaging of humans without navigation.

    Science.gov (United States)

    Robson, M D; Anderson, A W; Gore, J C

    1997-07-01

    A new method is proposed for reducing the artifacts produced in diffusion-weighted imaging. When data are acquired using multiple shot echo planar acquisitions, conventional reconstruction methods produce artifactual images as a consequence of diffusion weighting and small amounts of bulk motion of the subject. If the amount of motion can be determined, it is possible to correct the data before reconstruction, which removes the artifact. A method for estimating the motion from the acquired data has been developed and evaluated. This method assumes that ghost image effects will be minimized when motion has been correctly compensated. By considering the amount of signal in the background of the image, appropriate corrections to the data can be made, and the accuracy of the motion compensation may be estimated. This technique has been evaluated by computer simulation, and its performance has been demonstrated in a phantom and humans with both two- and four-shot echo planar acquisitions and using both "mosaic" and "interleaved" sampling schemes.

  6. Block-Matching Distortion Correction of Echo-Planar Images With Opposite Phase Encoding Directions.

    Science.gov (United States)

    Hedouin, Renaud; Commowick, Olivier; Bannier, Elise; Scherrer, Benoit; Taquet, Maxime; Warfield, Simon K; Barillot, Christian

    2017-05-01

    By shortening the acquisition time of MRI, Echo Planar Imaging (EPI) enables the acquisition of a large number of images in a short time, compatible with clinical constraints as required for diffusion or functional MRI. However such images are subject to large, local distortions disrupting their correspondence with the underlying anatomy. The correction of those distortions is an open problem, especially in regions where large deformations occur. We propose a new block-matching registration method to perform EPI distortion correction based on the acquisition of two EPI with opposite phase encoding directions (PED). It relies on new transformations between blocks adapted to the EPI distortion model, and on an adapted optimization scheme to ensure an opposite symmetric transformation. We present qualitative and quantitative results of the block-matching correction using different metrics on a phantom dataset and on in-vivo data. We show the ability of the block-matching to robustly correct EPI distortion even in strongly affected areas.

  7. Functional imaging of parotid glands: Diffusion-weighted echo-planar MRI before and after stimulation

    Energy Technology Data Exchange (ETDEWEB)

    Habermann, C.R.; Cramer, M.C.; Gossrau, P.; Adam, G. [University Hospital Hamburg-Eppendorf (Germany). Department of Diagnostic and Interventional Radiology; Graessner, J. [Siemens AG, Hamburg (Germany). Medical Solutions; Reitmeier, F.; Jaehne, M. [University Hospital Hamburg-Eppendorf (Germany). Department of Oto-, Rhino-, Laryngology; Fiehler, J. [University Hospital Hamburg-Eppendorf (Germany). Department of Neuroradiology; Schoder, V. [University Hospital Hamburg-Eppendorf (Germany). Institute for Medical Biometry and Epidemiology

    2004-10-01

    Purpose: To investigate the feasibility of diffusion-weighted (DW) echo-planar imaging (EPI) for measuring different functional conditions of the parotid gland and to compare different measurement approaches. Materials and Methods: Parotid glands of 27 healthy volunteers were examined with a DW EPI sequence (TR 1,500 msec, TE 77 msec, field-of-view 250 x 250 mm, pixel size 2.10 x 1.95 mm, section thickness 5 mm) before and after oral stimulation with commercially available lemon juice. The b factors used were 0, 500, and 1,000 sec/mm{sup 2}. Apparent diffusion coefficient (ADC) maps were digitally transferred to MRIcro (Chris Rorden, University of Nottingham, Great Britain) and evaluated with a manually placed circular region of interest (ROI) containing 100-200 pixel. Additional ROIs including the entire parotid gland were placed on either side. The results of both measurements were compared, using the Student's t test based on the median ADC values for each person. A two-tailed p-value of less than.05 was determined to indicate statistical significance. To compare both measurement approaches, the Pearson's correlation coefficient (r) was calculated. Results: Diffusion-weighted echo-planar MR imaging successfully visualized the parotid gland of all volunteers. In a first step, the median ADC value per person was computed. Using ROIs of 100-200 pixels, the mean was calculated to be 1.08 x 10{sup -3} mm{sup 2}/sec{+-}0.12 x 10{sup -3} mm{sup 2}/sec for both parotid glands prior to simulation. After stimulation, the mean ADC was measured at 1.15 x 10{sup -3} mm{sup 2}/sec{+-}0.11 x 10{sup -3} mm{sup 2}/sec for both parotid glands. Evaluating the entire parotid gland, the ADC was 1.12 x 10{sup -3} mm{sup 2}/sec{+-}0.08 x 10{sup -3} mm{sup 2}/sec prior to simulation, whereas the ADC increased to 1.18 x 10{sup -3} mm{sup 2}/sec{+-}0.09 x 10{sup -3} mm{sup 2}/sec after simulation with lemon juice. For both types of measurements, the increase in ADC after

  8. Anatomical constraints on visualization of the human hippocampus using echo-planar imaging

    International Nuclear Information System (INIS)

    Asano, Shuichiro; Kirino, Takaaki; Mihara, Ban; Sugishita, Morihiro

    2004-01-01

    Reliable visualization of the hippocampus on echo-planar imaging (EPI) is essential in analyzing memory function using functional magnetic resonance imaging. However, the hippocampal area is notoriously prone to susceptibility artifacts caused by structures at the skull base, and avoiding such artifacts by appropriately selecting the subjects for a study is of practical importance. To elucidate factors affecting the extent of the artifacts we obtained EPI in a total of 62 hippocampi from 31 healthy volunteers and evaluated various anatomical measurements possibly associated with the quality of the images. The hippocampal head was sufficiently well demonstrated on 40 of 62 images (65%), and there were two parameters that significantly differed between the good (n=40) and poor (n=22) imaging studies: The vertical diameter (DV) of the opening of the internal acoustic meatus (IAM) and the pneumatization rate of the sphenoid sinus (RP-SS). From logistic regression analysis with the stepwise method, in addition to these two factors, the distance between the hippocampal body and IAM (Dhippo-IAM) and the distance between the hippocampal head and the middle cranial fossa at the skull base (Dhippo-base) were extracted. DV-IAM, RP-SS, and Dhippo-base were negatively correlated with the good imaging of the hippocampal head. On the other hand, Dhippo-IAM was positively correlated. These easily measurable parameters will be helpful in selecting subjects and in increasing the efficiency of hippocampal visualization in studies on human memory function. (orig.)

  9. Study of internal structure of the human fetus in utero by echo-planar magnetic resonance imaging.

    Science.gov (United States)

    Johnson, I R; Stehling, M K; Blamire, A M; Coxon, R J; Howseman, A M; Chapman, B; Ordidge, R J; Mansfield, P; Symonds, E M; Worthington, B S

    1990-08-01

    The ultrafast echo-planar magnetic resonance imaging technology, developed and built in Nottingham, has been used to produce the first snapshot images of the human fetus in utero. The imager, operating at a proton resonance frequency of 22 MHz, produces transaxial views in 64 or 128 milliseconds. These images comprise either 64 x 128 or 128 x 128 pixels with an in-plane resolution of 3 x 3 mm2. The slice thickness is 10 mm. Fetal scans of up to 32 contiguous slices are produced in a few minutes. These have been used to study the internal structure of the uterus and the fetus in a range of cases with gestations ranging from 26 weeks to term. Echo-planar imaging seems particularly suitable as an imaging modality since its high speed obviates image blurring arising from fetal motion.

  10. Three-dimensional echo-planar cine imaging of cerebral blood supply using arterial spin labeling.

    Science.gov (United States)

    Shrestha, Manoj; Mildner, Toralf; Schlumm, Torsten; Robertson, Scott Haile; Möller, Harald

    2016-12-01

    Echo-planar imaging (EPI) with CYlindrical Center-out spatiaL Encoding (EPICYCLE) is introduced as a novel hybrid three-dimensional (3D) EPI technique. Its suitability for the tracking of a short bolus created by pseudo-continuous arterial spin labeling (pCASL) through the cerebral vasculature is demonstrated. EPICYCLE acquires two-dimensional planes of k-space along center-out trajectories. These "spokes" are rotated from shot to shot about a common axis to encode a k-space cylinder. To track a bolus of labeled blood, the same subset of evenly distributed spokes is acquired in a cine fashion after a short period of pCASL. This process is repeated for all subsets to fill the whole 3D k-space of each time frame. The passage of short pCASL boluses through the vasculature of a 3D imaging slab was successfully imaged using EPICYCLE. By choosing suitable sequence parameters, the impact of slab excitation on the bolus shape could be minimized. Parametric maps of signal amplitude, transit time, and bolus width reflected typical features of blood transport in large vessels. The EPICYCLE technique was successfully applied to track a short bolus of labeled arterial blood during its passage through the cerebral vasculature.

  11. Diffusion-weighted echo planar imaging of acute brain infarction. A preliminary report

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Haruyuki; Ezuka, Isamu; Ikegami, Yoh; Suda, Tsuyoshi; Kakinuma, Kenichi; Kanazawa, Tsutomu; Higuchi, Shoichi [Niigata Rosai Hospital, Joetsu (Japan)

    1999-12-01

    The clinical usefulness of diffusion-weighted echo planar imaging (DW-EPI) was studied in 55 patients with acute brain ischemia. Ischemic lesions were identified on DW-EPI as hyperintense regions in all patients before changes were detected by conventional magnetic resonance imaging techniques in 12 cases studied earlier than 6 hours after onset. The earliest case was verified on DW-EPI at 50 minutes after onset. The ultra-fast imaging technique took less than 2 minutes to perform even for restless patients. Three patients had cardioembolic middle cerebral artery occlusion, and emergent percutaneous transluminal recanalization was carried out. Chronological changes in the signal of brain ischemia on DW-EPI depended on the site and size of the lesion, lacunar infarct of basal ganglia, and/or massive infarct due to major vessel occlusion, and were affected by associated hemorrhagic events. Coronal DW-EPI could more easily demarcate ischemia in the brainstem and/or cerebellum than axial scans when susceptibility artifacts were present. Coronal scans also demonstrated the site and direction of the pyramidal tract and its anatomical correlation with the lesions. DW-EPI has potential for the diagnostic and therapeutic planning of patients with acute brain ischemia. (author)

  12. In Vivo 31P Echo-Planar Spectroscopic Imaging of Human Calf Muscle

    Science.gov (United States)

    Wilhelm, Thomas; Bachert, Peter

    2001-03-01

    Localized phosphorus-31 NMR spectra of human calf muscle in vivo were obtained by means of echo-planar spectroscopic imaging (EPSI) with a 1.5-T whole-body scanner. The technique permits the measurement of two-dimensional 31P SI data at a minimum acquisition time of 2.4 s (8×8 voxels, TR=300 ms). With 9.4 min measurement time (TR=1100 ms, 64 averages) and 25×25×40 mm spatial resolution in vivo the 31P NMR signal-to-noise ratio (S/N) of the phosphocreatine (PCr) resonance was about 45; the multiplets of nucleoside 5‧-triphosphates were resolved. Spectral quality permits quantitative assessment of the PCr signal in a measurement time that is shorter by a factor of 2 or more than the minimum measurement time feasible with chemical-shift imaging. In a functional EPSI study with a time resolution of 20.5 s on the calf muscle of volunteers, spectra showed a 40% decrease of the PCr signal intensity (at rest: S/N≅12) upon exertion of the muscle.

  13. The clinical utility of reduced-distortion readout-segmented echo-planar imaging in the head and neck region: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Koyasu, Sho; Iima, Mami; Umeoka, Shigeaki; Morisawa, Nobuko; Togashi, Kaori [Kyoto University, Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Sakyo-Ku, Kyoto (Japan); Porter, David A. [Siemens AG, MED MR PLM AW Neurology, Allee am Roethelheimpark 2, Erlangen (Germany); Ito, Juichi [Kyoto University, Department of Otolaryngology, Head and Neck Surgery, Graduate School of Medicine, Sakyo-Ku, Kyoto (Japan); Le Bihan, Denis [Kyoto University, Human Brain Research Center, Graduate School of Medicine, Sakyo-Ku, Kyoto (Japan); Neurospin, CEA-Saclay Center, Gif-sur-Yvette Cedex (France)

    2014-12-15

    To evaluate whether readout-segmented echo-planar imaging (RS-EPI) diffusion weighted image (DWI) can diminish image distortion in the head and neck area, compared with single-shot (SS)-EPI DWI. We conducted phantom and patient studies using 3 T magnetic resonance imaging (MRI) with a 16-channel coil. For the phantom study, we evaluated distortion and signal homogeneity in gel phantoms. For the patient study, 29 consecutive patients with clinically suspicious parotid lesions were prospectively enrolled. RS-EPI and SS-EPI DWI were evaluated by two independent readers for identification of organ/lesion and distortion, using semiquantitative scales and quantitative scores. Apparent diffusion coefficient (ADC) values and contrast-noise ratios of parotid tumours (if present; n = 15) were also compared. The phantom experiments showed that RS-EPI provided less distorted and more homogeneous ADC maps than SS-EPI. In the patient study, RS-EPI was found to provide significantly less distortion in almost all organs/lesions (p < 0.05), according to both semiquantitative scales and quantitative scores. There was no significant difference in ADC values and contrast-noise ratios between the two DWI techniques. The distortion in DWI was significantly reduced with RS-EPI in both phantom and patient studies. The RS-EPI technique provided more homogenous images than SS-EPI, and can potentially offer higher image quality in the head and neck area. (orig.)

  14. Measurement of T1 by echo-planar imaging and the construction of computer-generated images

    International Nuclear Information System (INIS)

    Mansfield, P.; Guilfoyle, D.N.; Ordidge, R.J.; Coupland, R.E.

    1986-01-01

    The high-speed echo-planar imaging (EPI) technique is used to obtain rapid T 1 and spin density measurements by a two-point method. It is shown that neglect of edge effects in the slice selection procedure leads to significant systematic errors in T 1 . T 1 maps for two young patients, obtained at 4.0 MHz, are presented. The T 1 and spin density values obtained are used to produce computer-generated images in inversion recovery simulations. These results demonstrate marked improvement in image contrast without paying the time penalty incurred in real experiments, thereby greatly increasing patient throughput potential. (author)

  15. Echo planar perfusion imaging with high spatial and temporal resolution: methodology and clinical aspects

    International Nuclear Information System (INIS)

    Bitzer, M.; Klose, U.; Naegele, T.; Friese, S.; Kuntz, R.; Voigt, K.; Fetter, M.; Opitz, H.

    1999-01-01

    The purpose of the present study was to analyse specific advantages of calculated parameter images and their limitations using an optimized echo-planar imaging (EPI) technique with high spatial and temporal resolution. Dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) was performed in 12 patients with cerebrovascular disease and in 13 patients with brain tumours. For MR imaging of cerebral perfusion an EPI sequence was developed which provides a temporal resolution of 0.68 s for three slices with a 128 x 128 image matrix. To evaluate DSC-MRI, the following parameter images were calculated pixelwise: (1) Maximum signal reduction (MSR); (2) maximum signal difference (ΔSR); (3) time-to-peak (T p ); and (4) integral of signal-intensity-time curve until T p (S Int ). The MSR maps were superior in the detection of acute infarctions and ΔSR maps in the delineation of vasogenic brain oedema. The time-to-peak (T p ) maps seemed to be highly sensitive in the detection of poststenotic malperfused brain areas (sensitivity 90 %). Hyperperfused areas of brain tumours were detectable down to a diameter of 1 cm with high sensitivity (> 90 %). Distinct clinical and neuroradiological conditions revealed different suitabilities for the parameter images. The time-to-peak (T p ) maps may be an important advantage in the detection of poststenotic ''areas at risk'', due to an improved temporal resolution using an EPI technique. With regard to spatial resolution, a matrix size of 128 x 128 is sufficient for all clinical conditions. According to our results, a further increase in matrix size would not improve the spatial resolution in DSC-MRI, since the degree of the vascularization of lesions and the susceptibility effect itself seem to be the limiting factors. (orig.)

  16. Feasibility and reproducibility of echo planar spectroscopic imaging on the quantification of hepatic fat.

    Directory of Open Access Journals (Sweden)

    Yi-Ru Lin

    Full Text Available 1H-MRS is widely regarded as the most accurate noninvasive method to quantify hepatic fat content (HFC. When practical period of breath holding, and acquisition of HFC over multiple liver areas is considered, a fast MR spectroscopic imaging technique is desired. The aim of this study is to examine the feasibility and reproducibility of echo planar spectroscopic imaging (EPSI on the quantification of HFC in subject with various HFCs.Twenty two volunteers were examined in a 3T MR system. The acquisition time of proposed EPSI protocol was 18 seconds. The EPSI scans were repeated 8 times for each subject to test reproducibility. The peak of water and individual peaks of fat including methyl, methylene, and allylic peaks at 0.9, 1.3, and 2.0 ppm were fitted. Calculated amount of water and fat content were corrected for T2 relaxation. The total HFC was defined as the combination of individual peaks. Standard deviation (SD, coefficient of variance (COV and fitting reliability of HFC quantified by LCModel were calculated.Our results show that the SDs of total HFC for all subjects are less than 2.5%. Fitting reliability is mostly under 10% and positively correlates with COV. Subjects separated into three subgroups according to quantified total HFC show that improved fitting reliability and reproducibility can be achieved on subjects with higher total HFC.We have demonstrated feasibility of the proposed EPSI protocols on the quantification of HFC over a whole slice of liver with scan time in a single breath hold.

  17. Clinical evaluation of multishot echo planar imaging after administration of superparamagnetic iron oxide for hepatic tumors

    International Nuclear Information System (INIS)

    Sugai, Yukio; Watanabe, Yorihisa; Ito, Kazushi; Hosoya, Takaaki; Yamaguchi, Koichi

    1998-01-01

    Ten cases of hepatocellular carcinoma and three cases of metastatic liver tumor were evaluated using breath-hold multishot echo planar imaging (EPI) before and after administration of super-paramagnetic iron oxide (SPIO), and the results were compared to those with breath-hold fast multi-planar SPGR (T 1 WI) and fat-suppressed respiratory-triggered FSE (T 2 WI). Qualitative imaging evaluation of lesion detectability showed that T 2 WI was much more useful than T 1 WI as previously reported, and more useful than EPI. Quantitative evaluation showed that the signal to noise (S/N) ratios of the liver parenchyma decreased after administration of SPIO and the changes were significant on all pulse sequences. The change ratio of the S/N ratio of the liver parenchyma after administration of SPIO on EPI was significantly higher than on T 1 WI and T 2 WI. The tumor-liver contrast to noise (C/N) ratios increased after administration of SPIO and the changes were significant on T 1 WI and T 2 WI, but not on EPI. These results suggested that the tumor S/N ratio decreased after administration of SPIO on EPI. The tumor diameters on EPI were significantly reduced after administration of SPIO. Magnetization and flow artifacts on EPI were detected in all cases and caused distortion: the signal decreased in the liver parenchyma. We concluded that EPI after administration of SPIO is not currently useful compared to other pulse sequences and cannot yet replace T 2 WI. (author)

  18. Clinical evaluation of echo-planar diffusion-weighted imaging (EPI-DWI) for diagnosis of breast cancer

    International Nuclear Information System (INIS)

    Nakajima, Mika; Nitatori, Toshiaki; Matsuda, Minoru; Fukushima, Hisaki; Ihara, Kuniko; Seki, Tsuneaki

    2008-01-01

    The purpose of this study was to compare echo-planar diffusion-weighted imaging (EPI-DWI) with dynamic contrast-enhanced magnetic resonance imaging (MRI) in terms of the rate of detection, extension, and quality of diagnosis of breast cancer in order to estimate the usefulness of EPI-DWI. One hundred and three cases of 101 patients who underwent MRI prior to surgery for breast cancer were evaluated. (papillotubular carcinoma 22; solid-tubular carcinoma 20; scirrhous carcinoma 45; mucinous carcinoma 2; medullary carcinoma 1; invasive lobular carcinoma 2; apocrine carcinoma 2; ductal carcinoma in situ (DCIS) and microinvasive ductal carcinoma 9). Twelve cases of benign lesion were also evaluated. Single-shot EPI-DWI was performed before routine dynamic MRI and images of cancer detection and cancer extension both were compared with the pathological findings. The apparent diffusion coefficient (ADC) values of the lesions were measured and compared to the ADC values of benign lesions and normal breast tissues. The differences between the ADC values for the various histopathological types and the time-intensity curve (TIC) patterns of the dynamic MRI were also estimated. The EPI-DWI demonstrated abnormal high-intensity areas corresponding to the breast cancer lesions; these areas demonstrated good correlation with the enhanced areas observed in the early phase of dynamic MRI and cancer extension in the pathological findings. Frequently, normal breast tissues manifested as high-intensity areas in EPI-DWI; however, it was possible to distinguish between normal breast tissues and breast lesions by correlating these images with T2- weighted images and corresponding ADC values. The threshold value between malignant and benign lesions that resulted both high sensitivity and specificity was about 1.5 x 10 -3 x mm 2 /second. Mucinous carcinoma and DCIS/ microinvasive carcinoma exhibited higher ADC values than those observed in the other histopathological types, however, no

  19. Measurement of T/sub 1/ by echo-planar imaging and the construction of computer-generated images

    Energy Technology Data Exchange (ETDEWEB)

    Mansfield, P.; Guilfoyle, D.N.; Ordidge, R.J.; Coupland, R.E.

    1986-02-01

    The high-speed echo-planar imaging (EPI) technique is used to obtain rapid T/sub 1/ and spin density measurements by a two-point method. It is shown that neglect of edge effects in the slice selection procedure leads to significant systematic errors in T/sub 1/. T/sub 1/ maps for two young patients, obtained at 4.0 MHz, are presented. The T/sub 1/ and spin density values obtained are used to produce computer-generated images in inversion recovery simulations. These results demonstrate marked improvement in image contrast without paying the time penalty incurred in real experiments, thereby greatly increasing patient throughput potential.

  20. Fast susceptibility-weighted imaging with three-dimensional short-axis propeller (SAP)-echo-planar imaging.

    Science.gov (United States)

    Holdsworth, Samantha J; Yeom, Kristen W; Moseley, Michael E; Skare, S

    2015-05-01

    Susceptibility-weighted imaging (SWI) in neuroimaging can be challenging due to long scan times of three-dimensional (3D) gradient recalled echo (GRE), while faster techniques such as 3D interleaved echo-planar imaging (iEPI) are prone to motion artifacts. Here we outline and implement a 3D short-axis propeller echo-planar imaging (SAP-EPI) trajectory as a faster, motion-correctable approach for SWI. Experiments were conducted on a 3T MRI system. The 3D SAP-EPI, 3D iEPI, and 3D GRE SWI scans were acquired on two volunteers. Controlled motion experiments were conducted to test the motion-correction capability of 3D SAP-EPI. The 3D SAP-EPI SWI data were acquired on two pediatric patients as a potential alternative to 2D GRE used clinically. The 3D GRE images had a better target resolution (0.47 × 0.94 × 2 mm, scan time = 5 min), iEPI and SAP-EPI images (resolution = 0.94 × 0.94 × 2 mm) were acquired in a faster scan time (1:52 min) with twice the brain coverage. SAP-EPI showed motion-correction capability and some immunity to undersampling from rejected data. While 3D SAP-EPI suffers from some geometric distortion, its short scan time and motion-correction capability suggest that SAP-EPI may be a useful alternative to GRE and iEPI for use in SWI, particularly in uncooperative patients. © 2014 Wiley Periodicals, Inc.

  1. Echo-planar magnetic resonance imaging (EPI) with high-resolution matrix in intra-axial brain tumors

    International Nuclear Information System (INIS)

    Bruening, R.; Scheidler, J.; Porn, U.; Reiser, M.; Seelos, K.; Yousry, T.; Exner, H.; Rosen, B.R.

    1999-01-01

    The aim of this study was to assess the potential of high-speed interleaved echo-planar imaging (EPI) to achieve diagnostic image quality comparable to T2-weighted imaging in patients with brain tumors. Seventeen patients with intra-axial, supratentorial tumors (10 untreated gliomas, 7 radiated gliomas) were investigated on a 1.5-T scanner. The conventional scan (SE, TR/TE = 2200/80 ms, 18 slices) was acquired in 8 min, 4 s, and EPI (TR/TE = 3000/80 ms, 18 slices) was completed in 25 s. The films were compared in a blinded trail by three radiologists. On the general impression and anatomic display, both sequences were rated to be of similar quality. Artifacts were slightly more pronounced at the skull base and around surgical clips using EPI. Tumor delineation was nearly equivalent using EPI, compared with the T2-weighted sequence. Echo-planar imaging reached diagnostic quality in all patients. Interleaved high-resolution EPI yielded sufficient quality to depict intra-axial, supratentorial brain tumors. Since EPI can be obtained in a small fraction of the time needed for conventional spin echo, in addition to other indications it could be considered to study patients unable to cooperate. (orig.)

  2. Echo-Planar Imaging for a 9.4 Tesla Vertical-Bore Superconducting Magnet Using an Unshielded Gradient Coil

    Science.gov (United States)

    KODAMA, Nao; KOSE, Katsumi

    2016-01-01

    Echo-planar imaging (EPI) sequences were developed for a 9.4 Tesla vertical standard bore (∼54 mm) superconducting magnet using an unshielded gradient coil optimized for live mice imaging and a data correction technique with reference scans. Because EPI requires fast switching of intense magnetic field gradients, eddy currents were induced in the surrounding metallic materials, e.g., the room temperature bore, and this produced serious artifacts on the EPI images. We solved the problem using an unshielded gradient coil set of proper size (outer diameter = 39 mm, inner diameter = 32 mm) with time control of the current rise and reference scans. The obtained EPI images of a phantom and a plant sample were almost artifact-free and demonstrated the promise of our approach. PMID:27001398

  3. Fast fluid-attenuated inversion recovery (FLAIR) magnetic resonance imaging of the brain: a comparison of multi-shot echo-planar and fast spin-echo techniques

    International Nuclear Information System (INIS)

    Sargent, M.A.; Poskitt, K.J.

    1997-01-01

    Purpose. To evaluate fast spin-echo and multi-shot echo-planar fluid-attenuated inversion recovery (FLAIR) sequences in paediatric brain imaging. Materials and methods. Matched images from 32 patients with suspected tumour or white matter disease were independently evaluated by two paediatric neuroradiologists. The observer preferences for image quality and lesion detection were analysed for differences between fast spin-echo FLAIR and multi-shot echo-planar FLAIR. Diagnostic quality was compared with that of fast spin-echo T2-weighted images. Results. Images of a diagnostic quality equivalent to that of fast spin-echo T2-weighted images were achieved with both FLAIR techniques. Grey and white matter differentiation and cerebrospinal fluid (CSF) nulling were significantly better on fast spin-echo FLAIR sequences. CSF flow artefact was reduced on multi-shot echo-planar FLAIR. There was no difference in lesion detection. Fast spin-echo FLAIR images were visually preferred at the expense of longer imaging time. Conclusion. Fast FLAIR techniques are complementary to fast spin-echo T2-weighted sequences in imaging of the paediatric brain. We find that the fast spin-echo FLAIR sequence is preferable to the multi-shot echo-planar technique. (orig.). With 5 figs., 2 tabs

  4. A pilot validation of multi-echo based echo-planar correlated spectroscopic imaging in human calf muscles.

    Science.gov (United States)

    Furuyama, Jon K; Nagarajan, Rajakumar; Roberts, Christian K; Lee, Cathy C; Hahn, Theodore J; Thomas, M Albert

    2014-10-01

    A current limitation of MR spectroscopic imaging of multiple skeletal muscles is prolonged scan duration. A significant reduction in the total scan duration using the echo-planar correlated spectroscopic imaging (EP-COSI) sequence was accomplished using two bipolar readout trains with different phase-encoded echoes for one of two spatial dimensions within a single repetition time (TR). The second bipolar readout was used for spatially encoding the outer k-space, whereas the first readout was used for the central k-space only. The performance of this novel sequence, called multi-echo based echo-planar correlated spectroscopic imaging (ME-EPCOSI), was demonstrated by localizing specific key features in calf muscles and bone marrow of 11 healthy volunteers and five subjects with type 2 diabetes (T2D). A 3 T MRI-MRS scanner equipped with a transmit-receive extremity coil was used. Localization of the ME-EPCOSI sequence was in good agreement with the earlier single-readout based EP-COSI sequence and the required scan time was reduced by a factor of two. In agreement with an earlier report using single-voxel based 2D MRS, significantly increased unsaturated pools of intramyocellular lipid (IMCL) and extramyocellular lipid (EMCL) and decreased IMCL and EMCL unsaturation indices (UIs) were observed in the soleus and tibialis anterior muscle regions of subjects with T2D compared with healthy controls. In addition, significantly decreased choline content was observed in the soleus of T2D subjects compared with healthy controls. Multi-voxel characterization of IMCL and EMCL ratios and UI in the calf muscle may be useful for the non-invasive assessment of altered lipid metabolism in the pathophysiology of T2D. Copyright © 2014 John Wiley & Sons, Ltd.

  5. Short repetition time multiband echo-planar imaging with simultaneous pulse recording allows dynamic imaging of the cardiac pulsation signal.

    Science.gov (United States)

    Tong, Yunjie; Hocke, Lia M; Frederick, Blaise deB

    2014-11-01

    Recently developed simultaneous multislice echo-planar imaging (EPI) sequences permit imaging of the whole brain at short repetition time (TR), allowing the cardiac fluctuations to be fully sampled in blood-oxygen-level dependent functional MRI (BOLD fMRI). A novel low computational analytical method was developed to dynamically map the passage of the pulsation signal through the brain and visualize the whole cerebral vasculature affected by the pulse signal. This algorithm is based on a simple combination of fast BOLD fMRI and the scanner's own built-in pulse oximeter. Multiple, temporally shifted copies of the pulse oximeter data (with 0.08 s shifting step and coverage of a 1-s span) were downsampled and used as cardiac pulsation regressors in a general linear model based analyses (FSL) of the fMRI data. The resulting concatenated z-statistics maps show the voxels that are affected as the cardiac signal travels through the brain. Many voxels were highly correlated with the pulsation regressor or its temporally shifted version. The dynamic and static cardiac pulsation maps obtained from both the task and resting state scans, resembled cerebral vasculature. The results demonstrated: (i) cardiac pulsation significantly affects most voxels in the brain; (ii) combining fast fMRI and this analytical method can reveal additional clinical information to functional studies. Copyright © 2013 Wiley Periodicals, Inc.

  6. In vivo carbon-edited detection with proton echo-planar spectroscopic imaging (ICED PEPSI) : [3,4-(CH2)-C-13] glutamate/glutamine tomography in rat brain

    NARCIS (Netherlands)

    Hyder, F; Renken, R; Rothman, DL

    1999-01-01

    A method for in vivo carbon-edited detection with proton echo-planar spectroscopic imaging (ICED PEPSI) is described. This method is composed of an echo-planar based acquisition implemented with C-13-H-1 J editing spectroscopy and is intended for high temporal and spatial resolution in vivo

  7. Snapshot gradient-recalled echo-planar images of rat brains at long echo time at 9.4 T.

    Science.gov (United States)

    Lei, Hongxia; Mlynárik, Vladimir; Just, Nathalie; Gruetter, Rolf

    2008-09-01

    With improved B 0 homogeneity along with satisfactory gradient performance at high magnetic fields, snapshot gradient-recalled echo-planar imaging (GRE-EPI) would perform at long echo times (TEs) on the order of T2*, which intrinsically allows obtaining strongly T2*-weighted images with embedded substantial anatomical details in ultrashort time. The aim of this study was to investigate the feasibility and quality of long TE snapshot GRE-EPI images of rat brain at 9.4 T. When compensating for B 0 inhomogeneities, especially second-order shim terms, a 200 x 200 microm2 in-plane resolution image was reproducibly obtained at long TE (>25 ms). The resulting coronal images at 30 ms had diminished geometric distortions and, thus, embedded substantial anatomical details. Concurrently with the very consistent stability, such GRE-EPI images should permit to resolve functional data not only with high specificity but also with substantial anatomical details, therefore allowing coregistration of the acquired functional data on the same image data set.

  8. Diuretic-enhanced gadolinium excretory MR urography: comparison of conventional gradient-echo sequences and echo-planar imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.C.A.; Tacke, J.; Adam, G.B.; Haage, P.; Guenther, R.W. [Univ. of Technology, Aachen (Germany). Dept. of Diagnostic Radiology; Jung, P.; Jakse, G. [Univ. of Technology, Aachen (Germany). Dept. of Urology

    2001-01-01

    The aim of this study was to investigate the utility of different gadolinium-enhanced T1-weighted gradient-echo techniques in excretory MR urography. In 74 urologic patients, excretory MR urography was performed using various T1-weighted gradient-echo (GRE) sequences after injection of gadolinium-DTPA and low-dose furosemide. The examinations included conventional GRE sequences and echo-planar imaging (GRE EPI), both obtained with 3D data sets and 2D projection images. Breath-hold acquisition was used primarily. In 20 of 74 examinations, we compared breath-hold imaging with respiratory gating. Breath-hold imaging was significantly superior to respiratory gating for the visualization of pelvicaliceal systems, but not for the ureters. Complete MR urograms were obtained within 14-20 s using 3D GRE EPI sequences and in 20-30 s with conventional 3D GRE sequences. Ghost artefacts caused by ureteral peristalsis often occurred with conventional 3D GRE imaging and were almost completely suppressed in EPI sequences (p < 0.0001). Susceptibility effects were more pronounced on GRE EPI MR urograms and calculi measured 0.8-21.7% greater in diameter compared with conventional GRE sequences. Increased spatial resolution degraded the image quality only in GRE-EPI urograms. (orig.)

  9. Accelerated three-dimensional cine phase contrast imaging using randomly undersampled echo planar imaging with compressed sensing reconstruction.

    Science.gov (United States)

    Basha, Tamer A; Akçakaya, Mehmet; Goddu, Beth; Berg, Sophie; Nezafat, Reza

    2015-01-01

    The aim of this study was to implement and evaluate an accelerated three-dimensional (3D) cine phase contrast MRI sequence by combining a randomly sampled 3D k-space acquisition sequence with an echo planar imaging (EPI) readout. An accelerated 3D cine phase contrast MRI sequence was implemented by combining EPI readout with randomly undersampled 3D k-space data suitable for compressed sensing (CS) reconstruction. The undersampled data were then reconstructed using low-dimensional structural self-learning and thresholding (LOST). 3D phase contrast MRI was acquired in 11 healthy adults using an overall acceleration of 7 (EPI factor of 3 and CS rate of 3). For comparison, a single two-dimensional (2D) cine phase contrast scan was also performed with sensitivity encoding (SENSE) rate 2 and approximately at the level of the pulmonary artery bifurcation. The stroke volume and mean velocity in both the ascending and descending aorta were measured and compared between two sequences using Bland-Altman plots. An average scan time of 3 min and 30 s, corresponding to an acceleration rate of 7, was achieved for 3D cine phase contrast scan with one direction flow encoding, voxel size of 2 × 2 × 3 mm(3) , foot-head coverage of 6 cm and temporal resolution of 30 ms. The mean velocity and stroke volume in both the ascending and descending aorta were statistically equivalent between the proposed 3D sequence and the standard 2D cine phase contrast sequence. The combination of EPI with a randomly undersampled 3D k-space sampling sequence using LOST reconstruction allows a seven-fold reduction in scan time of 3D cine phase contrast MRI without compromising blood flow quantification. Copyright © 2014 John Wiley & Sons, Ltd.

  10. A comparative quantitative analysis of magnetic susceptibility artifacts in echo planar and PROPELLER diffusion-weighted images

    Science.gov (United States)

    Cho, Jae-Hwan; Lee, Hae-Kag; Yang, Han-Joon; Lee, Gui-Won; Park, Yong-Soon; Chung, Woon-Kwan

    2013-01-01

    In this study, the authors investigated whether periodically-rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) diffusion-weighted imaging (DWI) can remove magnetic susceptibility artifacts and compared apparent diffusion coefficient (ADC) values for PROPELLER DWI and the common echo planar (EP) DWI. Twenty patients that underwent brain MRI with a metal dental implant were selected. A 3.0T MR scanner was then used to obtain EP DWI, PROPELLER DWI, and corresponding apparent diffusion coefficient (ADC) maps for a b-value of 0 and 1,000 s/mm2. The frequencies of magnetic susceptibility artifacts in four parts of the brain (bilateral temporal lobes, pons, and orbit) were selected. In the ADC maps, we measured the ADC values of both sides of the temporal lobe and the pons. According to the study results, the frequency of magnetic susceptibility artifacts in PROPELLER DW images was lower than it was in EP DW images. In ADC maps, the ADC values of the bilateral temporal lobes and the pons were all higher in PROPELLER ADC maps than in EP ADC maps. Our findings show that when a high-field MRI machine is used, magnetic susceptibility artifacts can distort anatomical structures and produce high-intensity signals. Furthermore, our findings suggest that in many cases, PROPELLER DWI would be helpful in terms of achieving a correct diagnosis.

  11. Sinusoidal echo-planar imaging with parallel acquisition technique for reduced acoustic noise in auditory fMRI.

    Science.gov (United States)

    Zapp, Jascha; Schmitter, Sebastian; Schad, Lothar R

    2012-09-01

    To extend the parameter restrictions of a silent echo-planar imaging (sEPI) sequence using sinusoidal readout (RO) gradients, in particular with increased spatial resolution. The sound pressure level (SPL) of the most feasible configurations is compared to conventional EPI having trapezoidal RO gradients. We enhanced the sEPI sequence by integrating a parallel acquisition technique (PAT) on a 3 T magnetic resonance imaging (MRI) system. The SPL was measured for matrix sizes of 64 × 64 and 128 × 128 pixels, without and with PAT (R = 2). The signal-to-noise ratio (SNR) was examined for both sinusoidal and trapezoidal RO gradients. Compared to EPI PAT, the SPL could be reduced by up to 11.1 dB and 5.1 dB for matrix sizes of 64 × 64 and 128 × 128 pixels, respectively. The SNR of sinusoidal RO gradients is lower by a factor of 0.96 on average compared to trapezoidal RO gradients. The sEPI PAT sequence allows for 1) increased resolution, 2) expanded RO frequency range toward lower frequencies, which is in general beneficial for SPL, or 3) shortened TE, TR, and RO train length. At the same time, it generates lower SPL compared to conventional EPI for a wide range of RO frequencies while having the same imaging parameters. Copyright © 2012 Wiley Periodicals, Inc.

  12. Single-shot polarimetry imaging of multicore fiber.

    Science.gov (United States)

    Sivankutty, Siddharth; Andresen, Esben Ravn; Bouwmans, Géraud; Brown, Thomas G; Alonso, Miguel A; Rigneault, Hervé

    2016-05-01

    We report an experimental test of single-shot polarimetry applied to the problem of real-time monitoring of the output polarization states in each core within a multicore fiber bundle. The technique uses a stress-engineered optical element, together with an analyzer, and provides a point spread function whose shape unambiguously reveals the polarization state of a point source. We implement this technique to monitor, simultaneously and in real time, the output polarization states of up to 180 single-mode fiber cores in both conventional and polarization-maintaining fiber bundles. We demonstrate also that the technique can be used to fully characterize the polarization properties of each individual fiber core, including eigen-polarization states, phase delay, and diattenuation.

  13. Assessment of Lipid and Metabolite Changes in Obese Calf Muscle Using Multi-Echo Echo-planar Correlated Spectroscopic Imaging.

    Science.gov (United States)

    Nagarajan, Rajakumar; Carpenter, Catherine L; Lee, Cathy C; Michael, Navin; Sarma, Manoj K; Souza, Raissa; Xu, Edward; Velan, S Sendhil; Hahn, Theodore J; Go, Vay-Liang; Thomas, M Albert

    2017-12-11

    Obesity-related conditions including heart disease, stroke, and type 2 diabetes are leading causes of preventable death. Recent evidence suggests that altered myocellular lipid metabolism in obesity may lead to increased insulin resistance (IR) that predisposes to these disorders. To test the hypothesis that muscles rich in type I vs. type II muscle fibers would exhibit similar changes in intramyocellular lipid (IMCL) and extramyocellular lipid (EMCL) content in obesity, we utilized a new four-dimensional multi echo echo-planar correlated spectroscopic imaging technique that allows separate determination of IMCL and EMCL content in individual calf muscles in obese vs. normal healthy human subjects. Calf muscles were scanned in 32 obese and 11 healthy subjects using a 3T MRI/MRS scanner, and IR in the obese subjects was documented by glucose tolerance testing. In obese subjects, elevation of both IMCL and EMCL content was observed in the gastrocnemius and tibialis anterior muscles (with mixed type I and II fiber content), while a significant increase in only IMCL content (+48%, p muscle (predominantly type I fibers). These observations indicate unexpected differences in changes in myolipid metabolism in type I vs. type II rich muscle regions in obesity, perhaps related to IR, and warrant further investigation.

  14. Distortion correction of echo planar images applying the concept of finite rate of innovation to point spread function mapping (FRIP).

    Science.gov (United States)

    Nunes, Rita G; Hajnal, Joseph V

    2018-01-03

    Point spread function (PSF) mapping enables estimating the displacement fields required for distortion correction of echo planar images. Recently, a highly accelerated approach was introduced for estimating displacements from the phase slope of under-sampled PSF mapping data. Sampling schemes with varying spacing were proposed requiring stepwise phase unwrapping. To avoid unwrapping errors, an alternative approach applying the concept of finite rate of innovation to PSF mapping (FRIP) is introduced, using a pattern search strategy to locate the PSF peak, and the two methods are compared. Fully sampled PSF data was acquired in six subjects at 3.0 T, and distortion maps were estimated after retrospective under-sampling. The two methods were compared for both previously published and newly optimized sampling patterns. Prospectively under-sampled data were also acquired. Shift maps were estimated and deviations relative to the fully sampled reference map were calculated. The best performance was achieved when using FRIP with a previously proposed sampling scheme. The two methods were comparable for the remaining schemes. The displacement field errors tended to be lower as the number of samples or their spacing increased. A robust method for estimating the position of the PSF peak has been introduced.

  15. Magnetic resonance fingerprinting using echo-planar imaging: Joint quantification of T1and T2∗ relaxation times.

    Science.gov (United States)

    Rieger, Benedikt; Zimmer, Fabian; Zapp, Jascha; Weingärtner, Sebastian; Schad, Lothar R

    2017-11-01

    To develop an implementation of the magnetic resonance fingerprinting (MRF) paradigm for quantitative imaging using echo-planar imaging (EPI) for simultaneous assessment of T 1 and T2∗. The proposed MRF method (MRF-EPI) is based on the acquisition of 160 gradient-spoiled EPI images with rapid, parallel-imaging accelerated, Cartesian readout and a measurement time of 10 s per slice. Contrast variation is induced using an initial inversion pulse, and varying the flip angles, echo times, and repetition times throughout the sequence. Joint quantification of T 1 and T2∗ is performed using dictionary matching with integrated B1+ correction. The quantification accuracy of the method was validated in phantom scans and in vivo in 6 healthy subjects. Joint T 1 and T2∗ parameter maps acquired with MRF-EPI in phantoms are in good agreement with reference measurements, showing deviations under 5% and 4% for T 1 and T2∗, respectively. In vivo baseline images were visually free of artifacts. In vivo relaxation times are in good agreement with gold-standard techniques (deviation T 1 : 4 ± 2%, T2∗: 4 ± 5%). The visual quality was comparable to the in vivo gold standard, despite substantially shortened scan times. The proposed MRF-EPI method provides fast and accurate T 1 and T2∗ quantification. This approach offers a rapid supplement to the non-Cartesian MRF portfolio, with potentially increased usability and robustness. Magn Reson Med 78:1724-1733, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  16. Quantitative Mapping of Total Choline in Healthy Human Breast Using Proton Echo Planar Spectroscopic Imaging (PEPSI) at 3 Tesla

    Science.gov (United States)

    Zhao, Chenguang; Bolan, Patrick J.; Royce, Melanie; Lakkadi, Navneeth; Eberhardt, Steven; Sillerud, Laurel; Lee, Sang-Joon; Posse, Stefan

    2012-01-01

    Purpose To quantitatively measure tCho levels in healthy breasts using Proton-Echo-Planar-Spectroscopic-Imaging (PEPSI). Material and Methods The 2-dimensional mapping of tCho at 3 Tesla across an entire breast slice using PEPSI and a hybrid spectral quantification method based on LCModel fitting and integration of tCho using the fitted spectrum were developed. This method was validated in 19 healthy females and compared with single voxel spectroscopy (SVS) and with PRESS prelocalized conventional Magnetic Resonance Spectroscopic Imaging (MRSI) using identical voxel size (8 cc) and similar scan times (~7 min). Results A tCho peak with a signal to noise ratio larger than 2 was detected in 10 subjects using both PEPSI and SVS. The average tCho concentration in these subjects was 0.45 ± 0.2 mmol/kg using PEPSI and 0.48±0.3 mmol/kg using SVS. Comparable results were obtained in 2 subjects using conventional MRSI. High lipid content in the spectra of 9 tCho negative subjects was associated with spectral line broadening of more than 26 Hz, which made tCho detection impossible. Conventional MRSI with PRESS prelocalization in glandular tissue in two of these subjects yielded tCho concentrations comparable to PEPSI. Conclusion The detection sensitivity of PEPSI is comparable to SVS and conventional PRESS-MRSI. PEPSI can be potentially used in the evaluation of tCho in breast cancer. A tCho threshold concentration value of ~0.7mmol/kg might be used to differentiate between cancerous and healthy (or benign) breast tissues based on this work and previous studies. PMID:22782667

  17. Image quality assessment of single-shot turbo spin echo diffusion-weighted imaging with parallel imaging technique: a phantom study.

    Science.gov (United States)

    Yoshida, Tsukasa; Urikura, Atsushi; Shirata, Kensei; Nakaya, Yoshihiro; Terashima, Shingo; Hosokawa, Yoichiro

    2016-09-01

    This study aimed to evaluate the image quality and apparent diffusion coefficient (ADC) values of single-shot turbo spin echo (TSE) diffusion-weighted (DW) images obtained using a parallel imaging (PI) technique. All measurements were performed on a 3.0-T whole-body MRI system and 32-channel phased-array coil. Signal-to-noise ratio (SNR) and ADC values were measured with a DW imaging (DWI) phantom comprising granulated sugar and agar. The SNRs were calculated using a subtraction method and compared among TSE-DW images at acceleration factors (AFs) of 1-4. Image blur was visually assessed on TSE-DW images of a pin phantom at AFs of 1-4. The ADC values were calculated using DW images with b = 0 and 1000 s mm(-2). The ADC values of TSE-DW images and echo-planar imaging EPI-DW images were compared. The SNRs decreased as AFs increased, despite selecting the shortest echo time. A lower AF caused increased image blur in the phase-encoding direction. The ADC values of TSE-DWI tended to be lower than those of EPI-DWI, and AFs of 3 and 4 yielded variable ADC values on TSE-DW images. TSE-DWI with an AF of 3 or 4 yielded reduced SNRs; in addition, the image noise and artefacts associated with PI technique may have affected ADC measurements, despite improving image blur in the phase-encoding direction. Optimizing the imaging parameters of TSE-DWI is useful for providing good image quality and accurate ADC measurements.

  18. The Usefulness of Readout-Segmented Echo-Planar Imaging (RESOLVE) for Bio-phantom Imaging Using 3-Tesla Clinical MRI.

    Science.gov (United States)

    Yoshimura, Yuuki; Kuroda, Masahiro; Sugiantoc, Irfan; Bamgbosec, Babatunde O; Miyahara, Kanae; Ohmura, Yuichi; Kurozumi, Akira; Matsushita, Toshi; Ohno, Seiichiro; Kanazawa, Susumu; Asaumi, Junichi

    2018-02-01

    Readout-segmented echo-planar imaging (RESOLVE) is a multi-shot echo-planar imaging (EPI) modality with k-space segmented in the readout direction. We investigated whether RESOLVE decreases the distortion and artifact in the phase direction and increases the signal-to-noise ratio (SNR) in phantoms image taken with 3-tesla (3T) MRI versus conventional EPI. We used a physiological saline phantom and subtraction mapping and observed that RESOLVE's SNR was higher than EPI's. Using RESOLVE, the combination of a special-purpose coil and a large-loop coil had a higher SNR compared to using only a head/neck coil. RESOLVE's image distortioas less than EPI's. We used a 120 mM polyethylene glycol phantom to examine the phase direction artifact.vThe range where the artifact appeared in the apparent diffusion coefficient (ADC) image was shorter with RESOLVE compared to EPI. We used RESOLVE to take images of a Jurkat cell bio-phantom: the cell-region ADC was 856×10-6mm2/sec and the surrounding physiological saline-region ADC was 2,951×10-6mm2/sec. The combination of RESOLVE and the 3T clinical MRI device reduced image distortion and improved SNR and the identification of accurate ADC values due to the phase direction artifact reduction. This combination is useful for obtaining accurate ADC values of bio-phantoms.

  19. Echo planar imaging in paediatrics: real-time-nuclear magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Rzedzian, R.; Doyle, M.; Mansfield, P.; Chapman, B.; Guilfoyle, D.; Coupland, R.E.; Small, P. (Universite of Nottingham (UK)); Chrispin, A. (City Hospital, Nottingham (UK))

    In 1982 Ordidge, Mansfield, Doyle and Coupland reported the first EPI movie images which were obtained using rabbits. From this study the potential use of EPI in human beings became clear. EPI is a distinctive usage of Nuclear Magnetic Resonance. Transaxial images are acquired in a very short period of time and so they are not blurred. These images accumulate in rapid sequence at each level of the anatomical transection. Each image may be linked to the events of the cardiac cycle. Construction of images in the sagittal and coronal planes may be carried out. This technique is particularly appropriate in the examination of the intrathoracic content of the infant or child. The rapidly contracting heart and the events associated with respiratory movement do not constitute a handicap to imaging the heart and great vessels and the lungs. It is this aspect of EPI which will be presented. The chambers of the heart and the great vessels may be delineated by EPI, yielding both anatomical and functional information. The pulmonary vessels may be seen in the central parts of the lungs. Alterations in proton density in the lung fields may be investigated by EPI. EPI is particularly appropriate for the examination of children for it is rapidly carried out and devoid of known hazard. Access to the patient is excellent throughout the examination.

  20. Echo planar imaging in paediatrics: real-time-nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Rzedzian, R.; Doyle, M.; Mansfield, P.; Chapman, B.; Guilfoyle, D.; Coupland, R.E.; Small, P.; Chrispin, A.

    1984-01-01

    In 1982 Ordidge, Mansfield, Doyle and Coupland reported the first EPI movie images which were obtained using rabbits. From this study the potential use of EPI in human being became clear. EPI is a distinctive usage of Nuclear Magnetic Resonance. Transaxial images are acquired in a very short period of time and so they are not blurred. These images accumulate in rapid sequence at each level of the anatomical transection. Each image may be linked to the events of the cardiac cycle. Constuction of images in the sagittal and coronal planes may be carried out. This technique is particularly appropriate in the examination of the intrathoracic content of the infant or child. The rapidly contracting heart and the events associated with respiratory movement do not constitute a handicap to imaging the heart and great vessels and the lungs. It is this aspect of EPI which will be presented. The chambers of the heart and the great vessels may be delineated by EPI, yielding both anatomical and functional information. The pulmonary vessels may be seen in the central parts of the lungs. Alterations in proton density in the lung fields may be investigated by EPI. EPI is particularly appropriate for the examination of children for it is rapidly carried out and devoid of known hazard. Access to the patient is excellent throughout the examination [fr

  1. Usefulness and limitation of functional MRI with echo planar imaging using clinical MR apparatus

    International Nuclear Information System (INIS)

    Kusunoki, Katsusuke; Zenke, Kiichiro; Saito, Masahiro; Sadamoto, Kazuhiko; Ohue, Shiro; Sakaki, Saburo; Kumon, Yoshiaki; Kabasawa, Hiroyuki; Nagasawa, Kiyoshi

    1998-01-01

    We studied blood oxygen level-dependent (BOLD) functional MRI (fMRI) with EPI sequence in 21 normal volunteers and 8 presurgical clinical patients using a 1.5 T clinical MRI apparatus. To optimize the imaging parameters, we compared the fMRI images obtained by GFE-EPI and by SE-EPI in normal volunteers while each squeezed a sponge ball. We identified the motor cortex in 85.7% of normal volunteers by GFE-EPI in contrast to only 28.6% by SE-EPI. In addition, our clinical MR apparatus, using optimized parameters, maximally provides 15 slices per 5 seconds. In patients with brain tumor close to the sensorimotor cortex, we attempted to identify the motor cortex preoperatively by this procedure and found a significant increase of signal intensity in the motor cortex in 5 of 8 patients. In conclusion, fMRI using EPI may be useful for identifying the motor cortex preoperatively. However, further development of the apparatus is needed to obtain better temporal and spatial resolution for clinical applications. (author)

  2. Echo-Planar Imaging Relaxometry to Measure the Viscosity of a Model Meal

    Science.gov (United States)

    Marciani, L.; Manoj, P.; Hills, B. P.; Moore, R. J.; Young, P.; Fillery-Travis, A.; Spiller, R. C.; Gowland, P. A.

    1998-11-01

    A method for measuring noninvasively the viscosity of a polysaccharide model meal using the known relationship between relaxation times and polysaccharide concentration in solutionin vitrois presented. The aim is to develop a method for monitoring digesta viscosityin vivo,using EPI to capture the motion of the gastrointestinal lumen. The transverse relaxation rateT-12of locust bean gum solutions was calibrated against the zero-shear viscosity at 37°C. Differences in viscosity were distinguished significantly usingT-12measurements.T-12and viscosity were insensitive to exposure to gastric juice and changes in pH, and the model meal was well received by volunteers and provided good contrastin vivoin EPI images. Therefore it would be possible to use this method to monitor the changes in meal viscosity within the gastric lumenin vivo.

  3. High temporal resolution motion estimation using a self-navigated simultaneous multi-slice echo planar imaging acquisition.

    Science.gov (United States)

    Teruel, Jose R; Kuperman, Joshua M; Dale, Anders M; White, Nathan S

    2018-02-13

    Subject motion is known to produce spurious covariance among time-series in functional connectivity that has been reported to induce distance-dependent spurious correlations. To present a feasibility study for applying the extended Kalman filter (EKF) framework for high temporal resolution motion correction of resting state functional MRI (rs-fMRI) series using each simultaneous multi-slice (SMS) echo planar imaging (EPI) shot as its own navigator. Prospective feasibility study. Three human volunteers. 3T GE DISCOVERY MR750 scanner using a 32-channel head coil. Simultaneous multi-slice rs-fMRI sequence with repetition time (TR)/echo time (TE) = 800/30 ms, and SMS factor 6. Motion estimates were computed using two techniques: a conventional rigid-body volume-wise registration; and a high-temporal resolution motion estimation rigid-body approach. The reference image was resampled using the estimates obtained from both approaches and the difference between these predicted volumes and the original moving series was summarized using the normalized mean squared error (NMSE). Direct comparison of NMSE values. High-temporal motion estimation was always superior to volume-wise motion estimation for the sample presented. For staged continuous rotations, the NMSE using high-temporal resolution motion estimates ranged between [0.130, 0.150] for the first volunteer (in-plane rotations), between [0.060, 0.068] for the second volunteer (in-plane rotations), and between [0.063, 0.080] for the third volunteer (through-plane rotations). These values went up to [0.384, 0.464]; [0.136, 0.179]; and [0.080, 0.096], respectively, when using volume-wise motion estimates. Accurate high-temporal rigid-body motion estimates can be obtained for rs-fMRI taking advantage of simultaneous multi-slice EPI sub-TR shots. 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  4. Dynamic Multi-Coil Technique (DYNAMITE) Shimming for Echo-Planar Imaging of the Human Brain at 7 Tesla

    Science.gov (United States)

    Juchem, Christoph; Rudrapatna, S. Umesh; Nixon, Terence W.; de Graaf, Robin A.

    2014-01-01

    Gradient-echo echo-planar imaging (EPI) is the primary method of choice in functional MRI and other methods relying on fast MRI to image brain activation and connectivity. However, the high susceptibility of EPI towards B0 magnetic field inhomogeneity poses serious challenges. Conventional magnetic field shimming with low-order spherical harmonic (SH) functions is capable of compensating shallow field distortions, but performs poorly for global brain shimming or on specific areas with strong susceptibility-induced B0 distortions such as the prefrontal cortex (PFC). Excellent B0 homogeneity has been demonstrated recently in the human brain at 7 Tesla with the DYNAmic Multi-coIl TEchnique (DYNAMITE) for magnetic field shimming (Juchem et al., J Magn Reson (2011) 212:280-288). Here, we report the benefits of DYNAMITE shimming for multi-slice EPI and T2* mapping. A standard deviation of 13 Hz was achieved for the residual B0 distribution in the human brain at 7 Tesla with DYNAMITE shimming and was 60% lower compared to conventional shimming that employs static zero through third order SH shapes. The residual field inhomogeneity with SH shimming led to an average 8 mm shift at acquisition parameters commonly used for fMRI and was reduced to 1.5-3 mm with DYNAMITE shimming. T2* values obtained from the prefrontal and temporal cortices with DYNAMITE shimming were 10-50% longer than those measured with SH shimming. The reduction of the confounding macroscopic B0 field gradients with DYNAMITE shimming thereby promises improved access to the relevant microscopic T2* effects. The combination of high spatial resolution and DYNAMITE shimming allows largely artifact-free EPI and T2* mapping throughout the brain, including prefrontal and temporal lobe areas. DYNAMITE shimming is expected to critically benefit a wide range of MRI applications that rely on excellent B0 magnetic field conditions including EPI-based fMRI to study various cognitive processes and assessing large

  5. Clinical single-shot diffusion-weighted MRI of the human brain on a short-bore medium-field imager

    International Nuclear Information System (INIS)

    Loevblad, K.O.; Remonda, L.; Schneider, J.; Goenner, F.; Schroth, G.; Heid, O.

    1999-01-01

    Diffusion-weighted MRI (DWI) is becoming important for assessment of acute stroke. Until recently single-shot DWI required expensive technology such as echo-planar imaging (EPI) available only at some research sites. A new medium-field (1.0 T) short-bore MR imager has been developed with which DWI data sets can be acquired. We prospectively studied 169 patients on this 1.0 T commercial system. After conventional imaging, DWI was performed with a single-shot multi-slice sequence with b values 0 an 900 s/mm 2 , and with the gradients switched in three directions. The apparent diffusion coefficients were calculated with online calculation software. There were 50 patients with totally normal MRI, and 17 had strokes, these strokes were detected as areas of high signal on the images at a maximal b value. There was a drop in the ADC in ischaemic regions: in subacute infarcts, the values were between 0.41 and 0.531 x 10 - 3 mm 2 /s. In old infarcts the ADC was 1.15 x 10 - 3 mm 2 /s. Cerebrospinal fluid (CSF) gave low signal whereas areas in the brain had more intermediate intensities (CSF: 3.00; deep white matter: 0.75, cortical grey matter: 0.80, basal ganglia (thalamus): 0.70 and cerebellar white matter: 0.65 x 10 - 3 mm 2 /s). Anisotropy was detected as areas of restricted diffusion along the tracts. These preliminary data show that DWI can be aquired successfully on a medium-field short-bore system. This should allow the technique to be implemented at more sites, therefore facilitating the diagnosis of acute stroke and rendering early intervention feasible. (orig.)

  6. The value of single-shot turbo spin-echo diffusion-weighted MR imaging in the detection of middle ear cholesteatoma

    International Nuclear Information System (INIS)

    De Foer, Bert; Bernaerts, Anja; Maes, Joachim; Deckers, Filip; Pouillon, Marc; Vercruysse, Jean-Philippe; Somers, Thomas; Offeciers, Erwin; Michiels, Johan; Casselman, Jan W.

    2007-01-01

    Single-shot (SS) turbo spin-echo (TSE) diffusion-weighted (DW) magnetic resonance imaging (MRI) is a non echo-planar imaging (EPI) technique recently reported for the evaluation of middle ear cholesteatoma. We prospectively evaluated a SS TSE DW sequence in detecting congenital or acquired middle ear cholesteatoma and evaluated the size of middle ear cholesteatoma detectable with this sequence. The aim of this study was not to differentiate between inflammatory tissue and cholesteatoma using SS TSE DW imaging. A group of 21 patients strongly suspected clinically and/or otoscopically of having a middle ear cholesteatoma without any history of prior surgery were evaluated with late post-gadolinium MRI including this SS TSE DW sequence. A total of 21 middle ear cholesteatomas (5 congenital and 16 acquired) were found at surgery with a size varying between 2 and 19 mm. Hyperintense signal on SS TSE DW imaging compatible with cholesteatoma was found in 19 patients. One patient showed no hyperintensity due to autoevacuation of the cholesteatoma sac into the external auditory canal. Another patient showed no hyperintensity because of motion artifacts. This study shows the high sensitivity of this SS TSE DW sequence in detecting small middle ear cholesteatomas, with a size limit as small as 2 mm. (orig.)

  7. Algorithms for image recovery calculation in extended single-shot phase-shifting digital holography

    Science.gov (United States)

    Hasegawa, Shin-ya; Hirata, Ryo

    2018-02-01

    The single-shot phase-shifting method of image recovery using an inclined reference wave has the advantages of reducing the effects of vibration, being capable of operating in real time, and affording low-cost sensing. In this method, relatively low reference angles compared with that in the conventional method using phase shift between three or four pixels has been required. We propose an extended single-shot phase-shifting technique which uses the multiple-step phase-shifting algorithm and the corresponding multiple pixels which are the same as that of the period of an interference fringe. We have verified the theory underlying this recovery method by means of Fourier spectral analysis and its effectiveness by evaluating the visibility of the image using a high-resolution pattern. Finally, we have demonstrated high-contrast image recovery experimentally using a resolution chart. This method can be used in a variety of applications such as color holographic interferometry.

  8. Algorithms for image recovery calculation in extended single-shot phase-shifting digital holography

    Science.gov (United States)

    Hasegawa, Shin-ya; Hirata, Ryo

    2018-04-01

    The single-shot phase-shifting method of image recovery using an inclined reference wave has the advantages of reducing the effects of vibration, being capable of operating in real time, and affording low-cost sensing. In this method, relatively low reference angles compared with that in the conventional method using phase shift between three or four pixels has been required. We propose an extended single-shot phase-shifting technique which uses the multiple-step phase-shifting algorithm and the corresponding multiple pixels which are the same as that of the period of an interference fringe. We have verified the theory underlying this recovery method by means of Fourier spectral analysis and its effectiveness by evaluating the visibility of the image using a high-resolution pattern. Finally, we have demonstrated high-contrast image recovery experimentally using a resolution chart. This method can be used in a variety of applications such as color holographic interferometry.

  9. Comparison of Turbo Spin Echo and Echo Planar Imaging for intravoxel incoherent motion and diffusion tensor imaging of the kidney at 3 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Hilbert, Fabian; Wech, Tobias; Neubauer, Henning; Veldhoen, Simon; Bley, Thorsten Alexander; Koestler, Herbert [Wuerzburg Univ. (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie

    2017-10-01

    Echo Planar Imaging (EPI) is most commonly applied to acquire diffusion-weighted MR-images. EPI is able to capture an entire image in very short time, but is prone to distortions and artifacts. In diffusion-weighted EPI of the kidney severe distortions may occur due to intestinal gas. Turbo Spin Echo (TSE) is robust against distortions and artifacts, but needs more time to acquire an entire image compared to EPI. Therefore, TSE is more sensitive to motion during the readout. In this study we compare diffusion-weighted TSE and EPI of the human kidney with regard to intravoxel incoherent motion (IVIM) and diffusion tensor imaging (DTI). Images were acquired with b-values between 0 and 750 s/mm{sup 2} with TSE and EPI. Distortions were observed with the EPI readout in all volunteers, while the TSE images were virtually distortion-free. Fractional anisotropy of the diffusion tensor was significantly lower for TSE than for EPI. All other parameters of DTI and IVIM were comparable for TSE and EPI. Especially the main diffusion directions yielded by TSE and EPI were similar. The results demonstrate that TSE is a worthwhile distortion-free alternative to EPI for diffusion-weighted imaging of the kidney at 3 Tesla.

  10. Single-Shot, Volumetrically Illuminated, Three-Dimensional, Tomographic Laser-Induced-Fluorescence Imaging in a Gaseous Free Jet

    Science.gov (United States)

    2016-04-28

    Single- shot , volumetrically illuminated, three- dimensional, tomographic laser-induced- fluorescence imaging in a gaseous free jet Benjamin R. Halls...37081 Göttingen, Germany 4School of Mechanical Engineering, Purdue University, West Lafayette, IN 47907, USA 5trmeyer@purdue.edu 6james.gord...us.af.mil Abstract: Single- shot , tomographic imaging of the three-dimensional concentration field is demonstrated in a turbulent gaseous free jet in co-flow

  11. Comparison of intravoxel incoherent motion diffusion-weighted imaging between turbo spin-echo and echo-planar imaging of the head and neck

    Energy Technology Data Exchange (ETDEWEB)

    Mikayama, Ryoji; Yabuuchi, Hidetake; Nagatomo, Kazuya; Kimura, Mitsuhiro; Kumazawa, Seiji [Kyushu University, Department of Health Sciences, Graduate School of Medical Sciences, Fukuoka (Japan); Sonoda, Shinjiro; Kobayashi, Koji [Kyushu University Hospital, Division of Radiology, Department of Medical Technology, Fukuoka (Japan); Kawanami, Satoshi; Kamitani, Takeshi; Honda, Hiroshi [Kyushu University, Department of Clinical Radiology, Graduate School of Medical Sciences, Fukuoka (Japan)

    2018-01-15

    To compare image quality, apparent diffusion coefficient (ADC), and intravoxel incoherent motion (IVIM)-derived parameters between turbo spin-echo (TSE)-diffusion-weighted imaging (DWI) and echo-planar imaging (EPI)-DWI of the head and neck. Fourteen volunteers underwent head and neck imaging using TSE-DWI and EPI-DWI. Distortion ratio (DR), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), ADC and IVIM-derived parameters were compared between the two techniques. Bland-Altman analysis was performed to analyse reproducibility between the quantitative parameters of TSE-DWI and EPI-DWI. DR of TSE-DWI was significantly smaller than that of EPI-DWI. SNR and CNR of TSE-DWI were significantly higher than those of EPI-DWI. ADC and IVIM-derived parameters of TSE-DWI showed higher values than those of EPI-DWI, although the difference was not significant. Bland-Altman analysis showed wide limits of agreement between the two sequences. TSE-DWI can produce better image quality than EPI-DWI, while TSE-DWI possibly exhibits different values of quantitative parameters. Therefore, TSE-DWI could be a good alternative to EPI-DWI for patients sensitive to distortion. However, it is not recommended to use both TSE-DWI and EPI-DWI on follow-up. (orig.)

  12. Simultaneous Multislice Echo Planar Imaging With Blipped Controlled Aliasing in Parallel Imaging Results in Higher Acceleration: A Promising Technique for Accelerated Diffusion Tensor Imaging of Skeletal Muscle.

    Science.gov (United States)

    Filli, Lukas; Piccirelli, Marco; Kenkel, David; Guggenberger, Roman; Andreisek, Gustav; Beck, Thomas; Runge, Val M; Boss, Andreas

    2015-07-01

    The aim of this study was to investigate the feasibility of accelerated diffusion tensor imaging (DTI) of skeletal muscle using echo planar imaging (EPI) applying simultaneous multislice excitation with a blipped controlled aliasing in parallel imaging results in higher acceleration unaliasing technique. After federal ethics board approval, the lower leg muscles of 8 healthy volunteers (mean [SD] age, 29.4 [2.9] years) were examined in a clinical 3-T magnetic resonance scanner using a 15-channel knee coil. The EPI was performed at a b value of 500 s/mm2 without slice acceleration (conventional DTI) as well as with 2-fold and 3-fold acceleration. Fractional anisotropy (FA) and mean diffusivity (MD) were measured in all 3 acquisitions. Fiber tracking performance was compared between the acquisitions regarding the number of tracks, average track length, and anatomical precision using multivariate analysis of variance and Mann-Whitney U tests. Acquisition time was 7:24 minutes for conventional DTI, 3:53 minutes for 2-fold acceleration, and 2:38 minutes for 3-fold acceleration. Overall FA and MD values ranged from 0.220 to 0.378 and 1.595 to 1.829 mm2/s, respectively. Two-fold acceleration yielded similar FA and MD values (P ≥ 0.901) and similar fiber tracking performance compared with conventional DTI. Three-fold acceleration resulted in comparable MD (P = 0.199) but higher FA values (P = 0.006) and significantly impaired fiber tracking in the soleus and tibialis anterior muscles (number of tracks, P parallel imaging results in higher acceleration can remarkably reduce acquisition time in DTI of skeletal muscle with similar image quality and quantification accuracy of diffusion parameters. This may increase the clinical applicability of muscle anisotropy measurements.

  13. Ghost reduction in echo-planar imaging by joint reconstruction of images and line-to-line delays and phase errors.

    Science.gov (United States)

    Ianni, Julianna D; Welch, E Brian; Grissom, William A

    2017-10-16

    To correct line-to-line delays and phase errors in echo-planar imaging (EPI). EPI-trajectory auto-corrected image reconstruction (EPI-TrACR) is an iterative maximum-likelihood technique that exploits data redundancy provided by multiple receive coils between nearby lines of k-space to determine and correct line-to-line trajectory delays and phase errors that cause ghosting artifacts. EPI-TrACR was efficiently implemented using a segmented FFT and was applied to in vivo brain data acquired at 7 T across acceleration (1×-4×) and multishot factors (1-4 shots), and in a time series. EPI-TrACR reduced ghosting across all acceleration factors and multishot factors, compared to conventional calibrated reconstructions and the PAGE method. It also achieved consistently lower ghosting in the time series. Averaged over all cases, EPI-TrACR reduced root-mean-square ghosted signal outside the brain by 27% compared to calibrated reconstruction, and by 40% compared to PAGE. EPI-TrACR automatically corrects line-to-line delays and phase errors in multishot, accelerated, and dynamic EPI. While the method benefits from additional calibration data for initialization, it was not a requirement for most reconstructions. Magn Reson Med, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  14. Single-shot in-line digital holography without twin image

    Science.gov (United States)

    Nomura, Takanori

    2018-01-01

    In-line digital holography is conventional but still attractive because of its simple optical setup. In general, sequential phase-shifting technique is mandatory to remove twin-image which makes the reconstructed image quality low. However, sequential phase-shifting technique requires multiple recording. Multiple recording means that it is not suitable for a dynamic phenomenon. In this paper, two kinds of a single-shot in-line digital holography without twin-image using a diffused illumination are presented. One is a generalized phase-shifting digital holography and the other is a computational removal of twin-image. The ideas and their experimental results are given to confirm the feasibility.

  15. Fast Detection of Airports on Remote Sensing Images with Single Shot MultiBox Detector

    Science.gov (United States)

    Xia, Fei; Li, HuiZhou

    2018-01-01

    This paper introduces a method for fast airport detection on remote sensing images (RSIs) using Single Shot MultiBox Detector (SSD). To our knowledge, this could be the first study which introduces an end-to-end detection model into airport detection on RSIs. Based on the common low-level features between natural images and RSIs, a convolution neural network trained on large amounts of natural images was transferred to tackle the airport detection problem with limited annotated data. To deal with the specific characteristics of RSIs, some related parameters in the SSD, such as the scales and layers, were modified for more accurate and rapider detection. The experiments show that the proposed method could achieve 83.5% Average Recall at 8 FPS on RSIs with the size of 1024*1024. In contrast to Faster R-CNN, an improvement on AP and speed could be obtained.

  16. Compressive sensing sectional imaging for single-shot in-line self-interference incoherent holography

    Science.gov (United States)

    Weng, Jiawen; Clark, David C.; Kim, Myung K.

    2016-05-01

    A numerical reconstruction method based on compressive sensing (CS) for self-interference incoherent digital holography (SIDH) is proposed to achieve sectional imaging by single-shot in-line self-interference incoherent hologram. The sensing operator is built up based on the physical mechanism of SIDH according to CS theory, and a recovery algorithm is employed for image restoration. Numerical simulation and experimental studies employing LEDs as discrete point-sources and resolution targets as extended sources are performed to demonstrate the feasibility and validity of the method. The intensity distribution and the axial resolution along the propagation direction of SIDH by angular spectrum method (ASM) and by CS are discussed. The analysis result shows that compared to ASM the reconstruction by CS can improve the axial resolution of SIDH, and achieve sectional imaging. The proposed method may be useful to 3D analysis of dynamic systems.

  17. Functional imaging of submandibular glands: diffusion-weighted echo-planar MRI before and after stimulation; Diffusionsgewichtete MRT zur Funktionsdiagnostik der Glandula submandibularis

    Energy Technology Data Exchange (ETDEWEB)

    Arndt, C.; Cramer, M.C.; Weiss, F.; Kaul, M.G.; Adam, G.; Habermann, C.R. [Zentrum fuer Bildgebende Diagnostik und Intervention, Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum Hamburg-Eppendorf (Germany); Graessner, J. [Siemens Medical Solutions (Germany); Petersen, K. [Zentrum fuer Psychosoziale Medizin, Klinik und Poliklinik fuer Psychiatrie und Psychotherapie, Universitaetsklinikum Hamburg-Eppendorf (Germany); Reitmeier, F.; Jaehne, M. [Kopf und Hautzentrum, Klinik und Poliklinik fuer Hals-, Nasen- und Ohrenheilkunde, Universitaetsklinikum Hamburg Eppendorf (Germany)

    2006-09-15

    Purpose: To investigate the feasibility of diffusion-weighted (DWI) echo-planar imaging (EPI) to depict the submandibular glands and to measure different functional conditions. Materials and Methods: Twenty-seven healthy volunteers were examined. Diffusion weighted sequence was performed prior to stimulation. Exactly 30 seconds after a commercially available lemon juice was given orally, the diffusion weighted sequence was repeated. All examinations were performed by using a 1.5-T superconducting system with a 30 mT/m maximum gradient capability and maximum slew rate of 125 mT/m/sec (Magnetom Symphony, Siemens, Erlangen, Germany). The lower part of the circularly polarized (CP) head coil and a standard two-element CP neck array coil were used. The flexibility of the neck array coil allowed positioning the N1 element (upper part of the coil) right next to the submandibular gland. The axial diffusion-weighted EPI (echo planar imaging) sequence was performed using a matrix of 119 x 128, a field of view of 250 x 250 mm (pixel size 2.1 x 1.95 mm), a section thickness of 5 mm with an interslice gap of 1 mm. The b factors used were 0 sec/mm{sup 2}, 500 sec/mm{sup 2} and 1000 sec/mm{sup 2}. Apparent diffusion coefficient (ADC) maps were digitally transferred to MRIcro (Chris Rorden, University of Nottingham, Great Britain). After detecting the submandibular glands a region of interest (ROI) was placed manually exactly within the boarder of both submandibular glands, excluding the external carotid artery on ADC maps. These procedures were performed on all ADC slices the submandibular glands could be differentiated in before and after oral stimulation. For statistical comparison of results, a student's t-test was performed with an overall two-tailed significance level of p=0.05. Results: The visualization of the submandibular glands using the diffusion-weighted EPI sequence was possible in all of the 27 volunteers. Prior to oral stimulation an ADC of 1.31 x 10{sup -3

  18. Echo-Planar Imaging Based J-Resolved Spectroscopic Imaging for Improved Metabolite Detection in Prostate Cancer

    Science.gov (United States)

    2013-10-01

    fat. Artif Cells Blood Substit Immobil Biotechnol. 1994;22(4): 1477–83. 12. Maio A, Rifkin MD. Magnetic resonance imaging of prostate cancer...Med. Imaging 2011; 30: 1100–1115. 97. Wu B, Millane RP, Watts R, Bones PJ. Prior estimate based com- pressed sensing in parallel MRI. Magn. Reson

  19. Echo-Planar Imaging-Based, J-Resolved Spectroscopic Imaging for Improved Metabolite Detection in Prostate Cancer

    Science.gov (United States)

    2016-12-01

    Huda A, Nagarajan R, Furuyama J and Thomas MA. In Vivo Two-Dimensional Magnetic Resonance Spectroscopy "Comprehensive Biomedical Physics " Elsevier...planar spectroscopic imaging of J-coupled resonances in human brain at 3 and 4 Tesla . Magn Reson Med 2007; 58(2): 236-44. PMID: 17610279 14...1981;29:1153-1160. 7. Brüschweiler R, Zhang F. Covariance nuclear magnetic resonance spectroscopy. The Journal of chemical physics 2004;120:5253-5260. 8

  20. On the signal-to-noise ratio efficiency and slab-banding artifacts in three-dimensional multislab diffusion-weighted echo-planar imaging.

    Science.gov (United States)

    Engström, Mathias; Mårtensson, Magnus; Avventi, Enrico; Skare, Stefan

    2015-02-01

    Three-dimensional (3D) multislab diffusion-weighted echo-planar imaging (EPI) has been suggested as an alternative for high-resolution diffusion-weighted imaging. In this work, the key components of the sequence are investigated, optimal scan parameter settings suggested, and a signal-to-noise ratio (SNR) analysis, comparing 2D diffusion-weighted EPI and 3D multislab diffusion-weighted EPI, is performed. Slab profiles were measured using 3D multislab EPI to investigate slab profile saturation effects with respect to TR, T1 and overlap between slabs. For short TR values, two methods to reduce the slab banding artifacts are proposed. Moreover, the SNR for 2D and 3D multislab (3D-MS) DWI have been simulated for various anatomical coverages and slab thicknesses. Simulated 3D multislab scans were shown to be more SNR-efficient than a corresponding 2D scan, for all investigated anatomical coverages and slab thicknesses. Slab banding artifacts being negligible for long repetition times (TRs) were strong for a TR of 2000 ms, proving that they stem from T1 -saturation effects. This banding was largely reduced by the suggested correction methods. In the low TR regime, T1 -saturation effects between adjacent slabs need to be taken in consideration to avoid slab-banding artifacts for multislab sequences. With the proposed correction methods the difference between the SNR-optimal TR and the TR where slab-banding artifacts become acceptable is reduced. © 2014 Wiley Periodicals, Inc.

  1. Prior-knowledge Fitting of Accelerated Five-dimensional Echo Planar J-resolved Spectroscopic Imaging: Effect of Nonlinear Reconstruction on Quantitation.

    Science.gov (United States)

    Iqbal, Zohaib; Wilson, Neil E; Thomas, M Albert

    2017-07-24

    1 H Magnetic Resonance Spectroscopic imaging (SI) is a powerful tool capable of investigating metabolism in vivo from mul- tiple regions. However, SI techniques are time consuming, and are therefore difficult to implement clinically. By applying non-uniform sampling (NUS) and compressed sensing (CS) reconstruction, it is possible to accelerate these scans while re- taining key spectral information. One recently developed method that utilizes this type of acceleration is the five-dimensional echo planar J-resolved spectroscopic imaging (5D EP-JRESI) sequence, which is capable of obtaining two-dimensional (2D) spectra from three spatial dimensions. The prior-knowledge fitting (ProFit) algorithm is typically used to quantify 2D spectra in vivo, however the effects of NUS and CS reconstruction on the quantitation results are unknown. This study utilized a simulated brain phantom to investigate the errors introduced through the acceleration methods. Errors (normalized root mean square error >15%) were found between metabolite concentrations after twelve-fold acceleration for several low concentra- tion (OGM) human brain matter were quantified in vivo using the 5D EP-JRESI sequence with eight-fold acceleration.

  2. Echo-Planar Imaging-Based, J-Resolved Spectroscopic Imaging for Improved Metabolite Detection in Prostate Cancer

    Science.gov (United States)

    2016-12-01

    the spectrum shown in Fig. 4b, the (Cr+Spm+Cho)/Cit was calculated to be 0.395. The mean (Cr+Spm+Cho)/Cit value for all six volunteers from a sim - ilar...Ding Y, Maher EA, Sims RD, Choi C, Lewis MA, Kodibagkar VD. Compressive sensing could accelerate 1H MR metabolic imaging in the clinic. Radiology 2012...sequence utilizing maximum-echo sampling for acquisition (highlighted in gold ; FID; ADC, analog-to-digital converter). Half-echo sampling is started exactly

  3. Single shot imaging through turbid medium and around corner using coherent light

    Science.gov (United States)

    Li, Guowei; Li, Dayan; Situ, Guohai

    2018-01-01

    Optical imaging through turbid media and around corner is a difficult challenge. Even a very thin layer of a turbid media, which randomly scatters the probe light, can appear opaque and hide any objects behind it. Despite many recent advances, no current method can image the object behind turbid media with single record using coherent laser illumination. Here we report a method that allows non-invasive single-shot optical imaging through turbid media and around corner via speckle correlation. Instead of being as an obstacle in forming diffractionlimited images, speckle actually can be a carrier that encodes sufficient information to imaging through visually opaque layers. Optical imaging through turbid media and around corner is experimentally demonstrated using traditional imaging system with the aid of iterative phase retrieval algorithm. Our method require neither scan of illumination nor two-arm interferometry or long-time exposure in acquisition, which has new implications in optical sensing through common obscurants such as fog, smoke and haze.

  4. BOLD contrast fMRI of whole rodent tumour during air or carbogen breathing using echo-planar imaging at 1.5 T

    Energy Technology Data Exchange (ETDEWEB)

    Landuyt, W.; Bogaert, W. van den; Lambin, P. [Lab. of Experimental Radiobiology and Department of Radiotherapy/Oncology,Univ. Hospitals Leuven (Belgium); Hermans, R.; Bosmans, H.; Sunaert, S.; Beatse, E.; Farina, D.; Meijerink, M.; Zhang, H.; Marchal, G. [University Hospital, Leuven (Belgium). Dept. of Radiology

    2001-11-01

    The aim of this study was to evaluate the feasibility of functional MR imaging (fMRI) at 1.5 T, exploiting blood oxygenation level-dependent (BOLD) contrast, for detecting changes in whole-tumour oxygenation induced by carbogen (5% CO{sub 2}+95% O{sub 2}) inhalation of the host. Adult WAG/Rij rats with rhabdomyosarcomas growing subcutaneously in the lower flank were imaged when tumours reached sizes between 1 and 11 cm{sup 3} (n=12). Air and carbogen were alternatively supplied at 2 l/min using a snout mask. Imaging was done on a 1.5-T MR scanner using a T2*-weighted gradient-echo, echo-planar imaging (GE-EPI) sequence. Analysis of the whole-tumour EPI images was based on statistical parametric maps. Voxels with and without signal intensity changes (SIC) were recorded. Significance thresholds were set at p<0.05, corrected for multiple comparisons. In continuous air breathing condition, 3 of 12 tumours showed significant negative SIC and 1 tumour had a clear-cut positive SIC. The remaining tumours showed very little or no change. When switching to carbogen breathing, the SIC were significantly positive in 10 of 12 tumours. Negative SIC were present in 4 tumours, of which three were simultaneously characterised by positive SIC. The overall analysis indicated that 6 of the 12 tumours could be considered as strong positive responders to carbogen. Our research demonstrates the applicability of fMRI GE-EPI at 1.5 T to study whole-tumour oxygenation non-invasively. The observed negative SIC during air condition may reflect the presence of transient hypoxia during these measurements. Selection of tumours on the basis of their individual response to carbogen is possible, indicating a role of such non-invasive measurements for using tailor-made treatments. (orig.)

  5. Self-Calibrating Wave-Encoded Variable-Density Single-Shot Fast Spin Echo Imaging.

    Science.gov (United States)

    Chen, Feiyu; Taviani, Valentina; Tamir, Jonathan I; Cheng, Joseph Y; Zhang, Tao; Song, Qiong; Hargreaves, Brian A; Pauly, John M; Vasanawala, Shreyas S

    2018-04-01

    It is highly desirable in clinical abdominal MR scans to accelerate single-shot fast spin echo (SSFSE) imaging and reduce blurring due to T 2 decay and partial-Fourier acquisition. To develop and investigate the clinical feasibility of wave-encoded variable-density SSFSE imaging for improved image quality and scan time reduction. Prospective controlled clinical trial. With Institutional Review Board approval and informed consent, the proposed method was assessed on 20 consecutive adult patients (10 male, 10 female, range, 24-84 years). A wave-encoded variable-density SSFSE sequence was developed for clinical 3.0T abdominal scans to enable high acceleration (3.5×) with full-Fourier acquisitions by: 1) introducing wave encoding with self-refocusing gradient waveforms to improve acquisition efficiency; 2) developing self-calibrated estimation of wave-encoding point-spread function and coil sensitivity to improve motion robustness; and 3) incorporating a parallel imaging and compressed sensing reconstruction to reconstruct highly accelerated datasets. Image quality was compared pairwise with standard Cartesian acquisition independently and blindly by two radiologists on a scale from -2 to 2 for noise, contrast, confidence, sharpness, and artifacts. The average ratio of scan time between these two approaches was also compared. A Wilcoxon signed-rank tests with a P value under 0.05 considered statistically significant. Wave-encoded variable-density SSFSE significantly reduced the perceived noise level and improved the sharpness of the abdominal wall and the kidneys compared with standard acquisition (mean scores 0.8, 1.2, and 0.8, respectively, P variable-density sampling SSFSE achieves improved image quality with clinically relevant echo time and reduced scan time, thus providing a fast and robust approach for clinical SSFSE imaging. 1 Technical Efficacy: Stage 6 J. Magn. Reson. Imaging 2018;47:954-966. © 2017 International Society for Magnetic Resonance in Medicine.

  6. Effect of Task-Correlated Physiological Fluctuations and Motion in 2D and 3D Echo-Planar Imaging in a Higher Cognitive Level fMRI Paradigm.

    Science.gov (United States)

    Ladstein, Jarle; Evensmoen, Hallvard R; Håberg, Asta K; Kristoffersen, Anders; Goa, Pål E

    2016-01-01

    To compare 2D and 3D echo-planar imaging (EPI) in a higher cognitive level fMRI paradigm. In particular, to study the link between the presence of task-correlated physiological fluctuations and motion and the fMRI contrast estimates from either 2D EPI or 3D EPI datasets, with and without adding nuisance regressors to the model. A signal model in the presence of partly task-correlated fluctuations is derived, and predictions for contrast estimates with and without nuisance regressors are made. Thirty-one healthy volunteers were scanned using 2D EPI and 3D EPI during a virtual environmental learning paradigm. In a subgroup of 7 subjects, heart rate and respiration were logged, and the correlation with the paradigm was evaluated. FMRI analysis was performed using models with and without nuisance regressors. Differences in the mean contrast estimates were investigated by analysis-of-variance using Subject, Sequence, Day, and Run as factors. The distributions of group level contrast estimates were compared. Partially task-correlated fluctuations in respiration, heart rate and motion were observed. Statistically significant differences were found in the mean contrast estimates between the 2D EPI and 3D EPI when using a model without nuisance regressors. The inclusion of nuisance regressors for cardiorespiratory effects and motion reduced the difference to a statistically non-significant level. Furthermore, the contrast estimate values shifted more when including nuisance regressors for 3D EPI compared to 2D EPI. The results are consistent with 3D EPI having a higher sensitivity to fluctuations compared to 2D EPI. In the presence partially task-correlated physiological fluctuations or motion, proper correction is necessary to get expectation correct contrast estimates when using 3D EPI. As such task-correlated physiological fluctuations or motion is difficult to avoid in paradigms exploring higher cognitive functions, 2D EPI seems to be the preferred choice for higher

  7. Assessment of cerebral blood flow reserve using blood oxygen level-dependent echo planar imaging after acetazolamide administration in patients post-STA-MCA anastomosis surgery

    International Nuclear Information System (INIS)

    Zenke, Kiichiro; Kusunoki, Katsusuke; Saito, Masahiro; Sadamoto, Kazuhiko; Ohta, Shinsuke; Kumon, Yoshiaki; Sakaki, Saburo; Nagasawa, Kiyoshi

    1998-01-01

    Recently, blood oxygen level-dependent (BOLD) echo planar imaging (EPI) has been used to estimate blood flow changes. Theoretically, a relative decrement of deoxyhemoglobin in cerebral blood supply induces a MR signal change after neuronal stimulation. In the present study, we have attempted to evaluate CBF reserve capacity by the BOLD EPI in patients who had undergone STA-MCA anastomosis surgery. Then, we compared with the signal intensity changes obtained by this procedure with the CBF changes by Xe-SPECT after acetazolamide administration. Six patients, post-STA-MCA anastomosis surgery, were studied. Pre-operatively, MR signal intensity and CBF, by Xe-SPECT, were increased in the intact side after acetazolamide administration in all patients, and MR signal intensities were decreased in low flow regions after acetazolamide administration in all four patients in whom so-called steal phenomenon was demonstrated by Xe-SPECT study. Post-operatively, poor response was shown after acetazolamide administration with both Xe-SPECT and BOLD EPI in the two patients who had unsuccessful anastomoses. In the successfully anastomosed patients, improved vascular reactivity was demonstrated on BOLD EPI after acetazolamide administration in 3 of 4 patients in whom an improvement of vascular reactivity was demonstrated on Xe-SPECT. In one patient, MRI studies were considered to have technical artifacts, because the MR signal intensity did not increase, even in the intact side after acetazolamide administration. In conclusion, BOLD EPI after acetazolamide administration is an useful procedure for the pre- and post-operative of vascular reserve in patients with ischemic stroke. (author)

  8. Utility of echo-planar gradient-echo T2*-weighted MR images in patients with primary intracerebral hemorrhage

    International Nuclear Information System (INIS)

    Yokoe, Toshio; Yoshida, Tazuka; Kobayashi, Nozomu; Nakamura, Yukihiro; Kubota, Kazuyuki

    2005-01-01

    Magnetic resonance imaging (MRI) has the potential to reveal residues of intracerabral hemorrhage (ICH) throughout life because of the high sensitivity for iron-containing compounds. Gradient-echo T2 * -weighted MR imaging (T2 * MRI) requiring short times for complete acquisition is known to detect small areas of signal loss without surrounding edema representing microbleeds (MBs). MBs in the basal ganglia including the thalami are suggested to be closely related to intracerebral atherosclerotic microangiopathy. We looked for more than 3 MBs in basal ganglia or thalamus of patients with and without episodes of previous ICH. Twelve patients with previous hemorrhagic stroke and 82 without were studied. Multiple MBs in those regions were significantly more frequent in patients with recurrent ICH. In addition, a 76-year-old woman with a history of hypertension was transferred to our hospital for treatment of head injury. She had multiple incidental old basal ganglionic and thalamic MBs. The patient had an asymptomatic primary ICH on computed tomography (CT) 3 months later. In conclusion, MR evidence of multiple MBs in the basal ganglia and thalamus might identify patients at a risk for new and recurrent ICH. Therefore, patients with multiple MBs in those regions should be treated for cerebrovascular risk factors, especially hypertension. Our results appear to confirm the utility of T2 * MRI in hemorrhagic stroke. (author)

  9. Femtosecond Single-Shot Imaging of Nanoscale Ferromagnetic Order in Co/Pd Multilayers using Resonant X-ray Holography

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Tianhan; Zhu, Diling; Benny Wu,; Graves, Catherine; Schaffert, Stefan; Rander, Torbjorn; Muller, leonard; Vodungbo, Boris; Baumier, Cedric; Bernstein, David P.; Brauer, Bjorn; Cros, Vincent; Jong, Sanne de; Delaunay, Renaud; Fognini, Andreas; Kukreja, Roopali; Lee, Sooheyong; Lopez-Flores, Victor; Mohanty, Jyoti; Pfau, Bastian; Popescu, 5 Horia

    2012-05-15

    We present the first single-shot images of ferromagnetic, nanoscale spin order taken with femtosecond x-ray pulses. X-ray-induced electron and spin dynamics can be outrun with pulses shorter than 80 fs in the investigated fluence regime, and no permanent aftereffects in the samples are observed below a fluence of 25 mJ/cm{sup 2}. Employing resonant spatially-muliplexed x-ray holography results in a low imaging threshold of 5 mJ/cm{sup 2}. Our results open new ways to combine ultrafast laser spectroscopy with sequential snapshot imaging on a single sample, generating a movie of excited state dynamics.

  10. Generating multiple contrasts using single-shot radial T1 sensitive and insensitive steady-state imaging.

    Science.gov (United States)

    Benkert, Thomas; Bartsch, Andreas J; Blaimer, Martin; Jakob, Peter M; Breuer, Felix A

    2015-06-01

    Recently, the (Resolution Enhanced-) T1 insensitive steady-state imaging (TOSSI) approach has been proposed for the fast acquisition of T2 -weighted images. This has been achieved by balanced steady-state free precession (bSSFP) imaging between unequally spaced inversion pulses. The purpose of this work is to present an extension of this technique, considerably increasing both the efficiency and possibilities of TOSSI. A radial trajectory in combination with an appropriate view-sharing reconstruction is used. Because each projection traverses the contrast defining k-space center, several different contrasts can be extracted from a single-shot measurement. These contrasts include various T2 -weightings and T2 /T1 -weighting if an even number of inversion pulses is used, while an odd number allow the generation of several images with predefined tissue types cancelled. The approach is validated for brain and abdominal imaging at 3.0 Tesla. Results are compared with RE-TOSSI, bSSFP, and turbo spin-echo images and are shown to provide similar contrasts in a fraction of scan time. Furthermore, the potential utility of the approach is illustrated by images obtained from a brain tumor patient. Radial T1 sensitive and insensitive steady-state imaging is able to generate multiple contrasts out of one single-shot measurement in a short scan time. © 2014 Wiley Periodicals, Inc.

  11. Development and Characterization of Two-Dimensional Gratings for Single-Shot X-ray Phase-Contrast Imaging

    Directory of Open Access Journals (Sweden)

    Margarita Zakharova

    2018-03-01

    Full Text Available Single-shot grating-based phase-contrast imaging techniques offer additional contrast modalities based on the refraction and scattering of X-rays in a robust and versatile configuration. The utilization of a single optical element is possible in such methods, allowing the shortening of the acquisition time and increasing flux efficiency. One of the ways to upgrade single-shot imaging techniques is to utilize customized optical components, such as two-dimensional (2D X-ray gratings. In this contribution, we present the achievements in the development of 2D gratings with UV lithography and gold electroplating. Absorption gratings represented by periodic free-standing gold pillars with lateral structure sizes from 5 µm to 25 µm and heights from 5 µm to 28 µm have shown a high degree of periodicity and defect-free patterns. Grating performance was tested in a radiographic setup using a self-developed quality assessment algorithm based on the intensity distribution histograms. The algorithm allows the final user to estimate the suitability of a specific grating to be used in a particular setup.

  12. Frequency-Domain Tomography for Single-shot, Ultrafast Imaging of Evolving Laser-Plasma Accelerators

    Science.gov (United States)

    Li, Zhengyan; Zgadzaj, Rafal; Wang, Xiaoming; Downer, Michael

    2011-10-01

    Intense laser pulses propagating through plasma create plasma wakefields that often evolve significantly, e.g. by expanding and contracting. However, such dynamics are known in detail only through intensive simulations. Laboratory visualization of evolving plasma wakes in the ``bubble'' regime is important for optimizing and scaling laser-plasma accelerators. Recently snap-shots of quasi-static wakes were recorded using frequency-domain holography (FDH). To visualize the wake's evolution, we have generalized FDH to frequency-domain tomography (FDT), which uses multiple probes propagating at different angles with respect to the pump pulse. Each probe records a phase streak, imprinting a partial record of the evolution of pump-created structures. We then topographically reconstruct the full evolution from all phase streaks. To prove the concept, a prototype experiment visualizing nonlinear index evolution in glass is demonstrated. Four probes propagating at 0, 0.6, 2, 14 degrees to the index ``bubble'' are angularly and temporally multiplexed to a single spectrometer to achieve cost-effective FDT. From these four phase streaks, an FDT algorithm analogous to conventional CT yields a single-shot movie of the pump's self-focusing dynamics.

  13. Clinical application of Half Fourier Acquisition Single Shot Turbo Spin Echo (HASTE) imaging accelerated by simultaneous multi-slice acquisition.

    Science.gov (United States)

    Schulz, Jenni; P Marques, José; Ter Telgte, Annemieke; van Dorst, Anouk; de Leeuw, Frank-Erik; Meijer, Frederick J A; Norris, David G

    2018-01-01

    As a single-shot sequence with a long train of refocusing pulses, Half-Fourier Acquisition Single-Shot Turbo-Spin-Echo (HASTE) suffers from high power deposition limiting use at high resolutions and high field strengths, particularly if combined with acceleration techniques such as simultaneous multi-slice (SMS) imaging. Using a combination of multiband (MB)-excitation and PINS-refocusing pulses will effectively accelerate the acquisition time while staying within the SAR limitations. In particular, uncooperative and young patients will profit from the speed of the MB-PINS HASTE sequence, as clinical diagnosis can be possible without sedation. Materials and MethodsMB-excitation and PINS-refocusing pulses were incorporated into a HASTE-sequence with blipped CAIPIRINHA and TRAPS including an internal FLASH reference scan for online reconstruction. Whole brain MB-PINS HASTE data were acquired on a Siemens 3T-Prisma system from 10 individuals and compared to a clinical HASTE protocol. ResultsThe proposed MB-PINS HASTE protocol accelerates the acquisition by about a factor 2 compared to the clinical HASTE. The diagnostic image quality proved to be comparable for both sequences for the evaluation of the overall aspect of the brain, the detection of white matter changes and areas of tissue loss, and for the evaluation of the CSF spaces although artifacts were more frequently encountered with MB-PINS HASTE. ConclusionsMB-PINS HASTE enables acquisition of slice accelerated highly T2-weighted images and provides good diagnostic image quality while reducing acquisition time. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. MR imaging of the gastrointestinal tract with half-fourier single-shot fast spin echo (SSFSE)

    International Nuclear Information System (INIS)

    Boku, Houjun; Takehara, Yasuo; Isoda, Haruo; Isogai, Satoshi; Kaneko, Masao

    1999-01-01

    Our objective was to implement a non-invasive magnetic resonance imaging (MRI) technique combined with concentrated milk ingestion for depicting the gastrointestinal (GI) tract and detecting gastrointestinal motility and transit. The half-Fourier SSFSE (single-shot fast spin echo) sequence was optimized on the basis of a phantom study. In order to determine the feasibility of milk ingestion as a substitute for contrast medium, ten human volunteers were examined with SSFSE after two types of liquid ingestion (i.e., milk and water). The snapshot images provided subsecond data acquisition for each coronal plane, allowing visualization of peristalsis in the gastrointestinal tract in an almost real-time fashion, without motion-related image degradation, as would normally be seen using conventional MRI. There was no significant difference between concentrated milk and water in terms of depiction of the upper gastrointestinal tract; however, 10 min and 30 min after ingestion, concentrated milk showed better delineation of the intestine than that observed after water ingestion (p<0.01). MR gastrointestinal imaging is a non-invasive method that allows gastrointestinal depiction as well as analysis of motility and passage. Especially with concentrated milk ingestion, the distal intestines were well depicted with adequate contrast filling and distention. (author)

  15. MR imaging of the gastrointestinal tract with half-fourier single-shot fast spin echo (SSFSE)

    Energy Technology Data Exchange (ETDEWEB)

    Boku, Houjun; Takehara, Yasuo; Isoda, Haruo; Isogai, Satoshi; Kaneko, Masao [Hamamatsu Univ. School of Medicine, Shizuoka (Japan)

    1999-04-01

    Our objective was to implement a non-invasive magnetic resonance imaging (MRI) technique combined with concentrated milk ingestion for depicting the gastrointestinal (GI) tract and detecting gastrointestinal motility and transit. The half-Fourier SSFSE (single-shot fast spin echo) sequence was optimized on the basis of a phantom study. In order to determine the feasibility of milk ingestion as a substitute for contrast medium, ten human volunteers were examined with SSFSE after two types of liquid ingestion (i.e., milk and water). The snapshot images provided subsecond data acquisition for each coronal plane, allowing visualization of peristalsis in the gastrointestinal tract in an almost real-time fashion, without motion-related image degradation, as would normally be seen using conventional MRI. There was no significant difference between concentrated milk and water in terms of depiction of the upper gastrointestinal tract; however, 10 min and 30 min after ingestion, concentrated milk showed better delineation of the intestine than that observed after water ingestion (p<0.01). MR gastrointestinal imaging is a non-invasive method that allows gastrointestinal depiction as well as analysis of motility and passage. Especially with concentrated milk ingestion, the distal intestines were well depicted with adequate contrast filling and distention. (author)

  16. In vivo single-shot (13)C spectroscopic imaging of hyperpolarized metabolites by spatiotemporal encoding

    DEFF Research Database (Denmark)

    Schmidt, Rita; Laustsen, Christoffer; Dumez, Jean-Nicolas

    2014-01-01

    Hyperpolarized metabolic imaging is a growing field that has provided a new tool for analyzing metabolism, particularly in cancer. Given the short life times of the hyperpolarized signal, fast and effective spectroscopic imaging methods compatible with dynamic metabolic characterizations are nece......Hyperpolarized metabolic imaging is a growing field that has provided a new tool for analyzing metabolism, particularly in cancer. Given the short life times of the hyperpolarized signal, fast and effective spectroscopic imaging methods compatible with dynamic metabolic characterizations...

  17. Utility of single shot fast spin echo technique in evaluating pancreaticobiliary diseases: T2-weighted image and magnetic resonance cholangiopancreatography

    International Nuclear Information System (INIS)

    Choi, Byoung Wook; Kim, Myeong Jin; Chung, Jae Bok; Ko, Heung Kyu; Kim, Dong Joon; Kim, Joo Hee; Chung, Jae Joon; Yoo, Hyung Sik; Lee, Jong Tae

    1999-01-01

    To evaluate the accuracy of T2-weighted imaging an MR cholangiopancreatography using the single shot fast spin-echo technique for evaluating pancreaticobiliary disease. Between March and July 1997, axial and coronal T2-weighted images(TE: 80-200 msec) and MR cholangiopancreatograms (TE: 800-1200 msec) were obtained in two ways [single slab (thickness: 30-50 mm) and multislice acquisition under chemical fat saturation] using SSFSE pulse sequencing in 131 cases of suspected pancreati-cobiliary disease. The accuracy of SSFSE MR imaging was assessed in 89 lesions of 74 patients [male, 48; female, 26; age range, 30-86 (mean, 59) years] confirmed surgicopathologically (50 lesions in 39 patients) and clinically (39 lesions in 35 patients). Two radiologists reviewed the MR images and diagnosis was determined by consensus. Correct diagnosis was confirmed in 84 of 89 lesions (94%). Seven lesions were falsely interpreted, false positive and false negative results accounting for two and five cases, respectively. Two pancreatic cancers were misdiagnosed as pancreatitis and a cancer of the proximal common bile duct(CBD) was interpreted as a distal CBD cancer. The sensitivity of SSFSE MR imaging for malignancy was 93 %. One CBD stone revealed by endoscopic retrograde cholangiopancreatography (ERCP) was not detected on MR images. In contrast, a stone in the CBD seen on MR images was not apparent on subsequent ERCP. Sensitivity and specificity for calculous disease were 96% and 99.7%, respectively. A benign stricture of the ampulla of Vater was falsely interpreted as normal, and correct diagnosis was possible in two falsely diagnosed cases when MR images were reviewed retrospectively. The combination of T2-weighted and cholangiographic images using SSFSE is an accurate method for diagnosing pancreatcobiliary diseases

  18. Single-shot X-ray phase-contrast imaging using two-dimensional gratings

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Genta; Itoh, Hidenosuke; Nagai, Kentaro; Nakamura, Takashi; Yamaguchi, Kimiaki; Kondoh, Takeshi; Handa, Soichiro; Ouchi, Chidane; Teshima, Takayuki; Setomoto, Yutaka; Den, Toru [Frontier Research Center, Corporate R and D Headquarters, Canon Inc., 3-30-2 Shimomaruko, Ohta-ku, Tokyo 146-8501 (Japan); Optics Technology Development Center, Corporate R and D Headquarters, Canon Inc., 23-10, Kiyohara-Kogyodanchi, Utsunomiya Tochigi 321-3231 (Japan); Nanotechnology R and D Center, Corporate R and D Headquarters, Canon Inc., 3-30-2 Shimomaruko, Ohta-ku, Tokyo 146-8501 (Japan)

    2012-07-31

    We developed a two-dimensional gratings-based X-ray interferometer that requires only a single exposure for clinical radiography. The interferometer consisted of a checkerboard phase grating for {pi} phase modulation and a latticed amplitude grating. Using a synchrotron radiation source, the phase grating modulates the X-rays and generates a self-image, transformed to a moire fringe by the amplitude grating. To allow use of a conventional X-ray tube, the latticed source grating was installed downstream from the X-ray tube. Differential phase-contrast and scattering images in two orthogonal directions were obtained by Fourier analysis of the single moire fringe image and an absorption image. Results show that characteristic features of soft tissue in two orthogonal directions were clearly shown in the differential phase-contrast images.

  19. Ultrafast Holographic Image Recording by Single Shot Femtosecond Spectral Hole Burning

    National Research Council Canada - National Science Library

    Rebane, Aleksander

    2001-01-01

    .... This allowed us to record image holograms with 150-fs duration pulses without need to accumulate the SHB effect from many exposures. Results of this research show that it is possible to perform optical recording of data in frequency-domain on ultrafast time scale. These results can be used also as a new diagnostic tool for femtosecond dynamics in various ultrafast optical interactions.

  20. Non-contrast-enhanced imaging of haemodialysis fistulas using quiescent-interval single-shot (QISS) MRA: a feasibility study

    International Nuclear Information System (INIS)

    Okur, A.; Kantarci, M.; Karaca, L.; Yildiz, S.; Sade, R.; Pirimoglu, B.; Keles, M.; Avci, A.; Çankaya, E.; Schmitt, P.

    2016-01-01

    Aim: To assess the efficiency of a novel quiescent-interval single-shot (QISS) technique for non-contrast-enhanced magnetic resonance angiography (MRA) of haemodialysis fistulas. Materials and methods: QISS MRA and colour Doppler ultrasound (CDU) images were obtained from 22 haemodialysis patients with end-stage renal disease (ESRD). A radiologist with extensive experience in vascular imaging initially assessed the fistulas using CDU. Two observers analysed each QISS MRA data set in terms of image quality, using a five-point scale ranging from 0 (non-diagnostic) to 4 (excellent), and lumen diameters of all segments were measured. Results: One hundred vascular segments were analysed for QISS MRA. Two anastomosis segments were considered non-diagnostic. None of the arterial or venous segments were evaluated as non-diagnostic. The image quality was poorer for the anastomosis level compared to the other segments (p<0.001 for arterial segments, and p<0.05 for venous segments), while no significant difference was determined for other vascular segments. Conclusion: QISS MRA has the potential to provide valuable complementary information to CDU regarding the imaging of haemodialysis fistulas. In addition, QISS non-enhanced MRA represents an alternative for assessment of haemodialysis fistulas, in which the administration of iodinated or gadolinium-based contrast agents is contraindicated. - Highlights: • Close monitoring and early intervention in hemodialysis fistulas may prolong longevity fistulas. • DopplerUS, contrast enhanced CT and MRI are using assessment of hemodialysis fistulas. • QISS nonenhanced MR angiography represents an alternative for assessment of hemodialysis fistulas.

  1. Multimodal MRI in the characterization of glial neoplasms: the combined role of single-voxel MR spectroscopy, diffusion imaging and echo-planar perfusion imaging

    International Nuclear Information System (INIS)

    Zonari, Paolo; Baraldi, Patrizia; Crisi, Girolamo

    2007-01-01

    Diffusion-weighted imaging (DWI), perfusion-weighted imaging (PWI) and MR spectroscopy (MRS) provide useful data for tumor evaluation. To assess the contribution of these multimodal techniques in grading glial neoplasms, we compared the value of DWI, PWI and MRS in the evaluation of histologically proven high- and low-grade gliomas in a population of 105 patients. Independently for each modality, the following variables were used to compare the tumors: minimum apparent diffusion coefficient (ADC) and maximum relative cerebral blood volume (rCBV) normalized values between tumor and healthy tissue, maximum Cho/Cr ratio and minimum NAA/Cr ratio in tumor, and scored lactate and lipid values in tumor. The Mann-Whitney and Wilcoxon tests were employed to compare DWI, PWI and MRS between tumor types. Logistic regression analysis was used to determine which parameters best increased the diagnostic accuracy in terms of sensitivity, specificity, and positive and negative predictive values. ROC curves were determined for parameters with high sensitivity and specificity to identify threshold values to separate high- from low-grade lesions. Statistically significant differences were found for rCBV tumor/normal tissue ratio, and NAA/Cr ratio in tumor and Cho/Cr ratio in tumor between low- and high-grade tumors. The best performing single parameter for group classification was the normalized rCBV value; including all parameters, statistical significance was reached by rCBV tumor/normal tissue ratio, NAA/Cr tumor ratio and lactate. From the ROC curves, a high probability for a neoplasm to be a high-grade lesion was associated with a rCBV tumor/normal tissue ratio of >1.16 and NAA/Cr tumor ratio of <0.44. Combining PWI and MRS with conventional MR imaging increases the accuracy of the attribution of malignancy to glial neoplasms. The best performing parameter was found to be the perfusion level. (orig.)

  2. Multimodal MRI in the characterization of glial neoplasms: the combined role of single-voxel MR spectroscopy, diffusion imaging and echo-planar perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zonari, Paolo [Ospedale ' ' B. Ramazzini' ' , AUSL Modena, Neuroradiologia, Dipartimento Integrato di Neuroscienze, Carpi, Modena (Italy); Baraldi, Patrizia [Universita degli Studi di Modena e Reggio Emilia, Dipartimento di Scienze Biomediche, Sezione di Fisiologia, Modena (Italy); Crisi, Girolamo [Azienda Ospedaliero-Universitaria di Parma, Dipartimento ad Attivita Integrata di Neuroscienze, Parma (Italy)

    2007-10-15

    Diffusion-weighted imaging (DWI), perfusion-weighted imaging (PWI) and MR spectroscopy (MRS) provide useful data for tumor evaluation. To assess the contribution of these multimodal techniques in grading glial neoplasms, we compared the value of DWI, PWI and MRS in the evaluation of histologically proven high- and low-grade gliomas in a population of 105 patients. Independently for each modality, the following variables were used to compare the tumors: minimum apparent diffusion coefficient (ADC) and maximum relative cerebral blood volume (rCBV) normalized values between tumor and healthy tissue, maximum Cho/Cr ratio and minimum NAA/Cr ratio in tumor, and scored lactate and lipid values in tumor. The Mann-Whitney and Wilcoxon tests were employed to compare DWI, PWI and MRS between tumor types. Logistic regression analysis was used to determine which parameters best increased the diagnostic accuracy in terms of sensitivity, specificity, and positive and negative predictive values. ROC curves were determined for parameters with high sensitivity and specificity to identify threshold values to separate high- from low-grade lesions. Statistically significant differences were found for rCBV tumor/normal tissue ratio, and NAA/Cr ratio in tumor and Cho/Cr ratio in tumor between low- and high-grade tumors. The best performing single parameter for group classification was the normalized rCBV value; including all parameters, statistical significance was reached by rCBV tumor/normal tissue ratio, NAA/Cr tumor ratio and lactate. From the ROC curves, a high probability for a neoplasm to be a high-grade lesion was associated with a rCBV tumor/normal tissue ratio of >1.16 and NAA/Cr tumor ratio of <0.44. Combining PWI and MRS with conventional MR imaging increases the accuracy of the attribution of malignancy to glial neoplasms. The best performing parameter was found to be the perfusion level. (orig.)

  3. The value of single-shot black-blood MR imaging for mapping of the coronary arteries: a comparison of four different orientations during breath-holding and free breathing.

    NARCIS (Netherlands)

    Holland, A.E.; Engelbrecht, M.R.W.; Barentsz, J.O.; Heijstraten, F.M.J.; Goldfarb, J.W.

    2002-01-01

    The value of ECG-gated single-shot black-blood MR imaging for rapid visualization of the origin and course of the coronary arteries was investigated. The study population included 28 patients with known or suspected cardiac disease. ECG-gated single-shot black-blood MR acquisitions were acquired in

  4. A single-shot T2mapping protocol based on echo-split gradient-spin-echo acquisition and parametric multiplexed sensitivity encoding based on projection onto convex sets reconstruction.

    Science.gov (United States)

    Chu, Mei-Lan; Chang, Hing-Chiu; Oshio, Koichi; Chen, Nan-Kuei

    2018-01-01

    To develop a high-speed T 2 mapping protocol that is capable of accurately measuring T 2 relaxation time constants from a single-shot acquisition. A new echo-split single-shot gradient-spin-echo (GRASE) pulse sequence is developed to acquire multicontrast data while suppressing signals from most nonprimary echo pathways in Carr-Purcell-Meiboom-Gill (CPMG) echoes. Residual nonprimary pathway signals are taken into consideration when performing T 2 mapping using a parametric multiplexed sensitivity encoding based on projection onto convex sets (parametric-POCSMUSE) reconstruction method that incorporates extended phase graph modeling of GRASE signals. The single-shot echo-split GRASE-based T 2 mapping procedure was evaluated in human studies at 3 Tesla. The acquired data were compared with reference data obtained with a more time-consuming interleaved spin-echo echo planar imaging protocol. T 2 maps derived from conventional single-shot GRASE scans, in which nonprimary echo pathways were not appropriately addressed, were also evaluated. Using the developed single-shot T 2 mapping protocol, quantitatively accurate T 2 maps can be obtained with a short scan time (parametric-POCSMUSE reconstruction. Magn Reson Med 79:383-393, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  5. Simultaneous multi-slice echo planar diffusion weighted imaging of the liver and the pancreas: Optimization of signal-to-noise ratio and acquisition time and application to intravoxel incoherent motion analysis

    Energy Technology Data Exchange (ETDEWEB)

    Boss, Andreas, E-mail: andreas.boss@usz.ch [Institute of Diagnostic and Interventional Radiology, University Hospital Zurich (Switzerland); Barth, Borna; Filli, Lukas; Kenkel, David; Wurnig, Moritz C. [Institute of Diagnostic and Interventional Radiology, University Hospital Zurich (Switzerland); Piccirelli, Marco [Institute of Neuroradiology, University Hospital of Zurich (Switzerland); Reiner, Caecilia S. [Institute of Diagnostic and Interventional Radiology, University Hospital Zurich (Switzerland)

    2016-11-15

    Purpose: To optimize and test a diffusion-weighted imaging (DWI) echo-planar imaging (EPI) sequence with simultaneous multi-slice (SMS) excitation in the liver and pancreas regarding acquisition time (TA), number of slices, signal-to-noise ratio (SNR), image quality (IQ), apparent diffusion coefficient (ADC) quantitation accuracy, and feasibility of intravoxel incoherent motion (IVIM) analysis. Materials and methods: Ten healthy volunteers underwent DWI of the upper abdomen at 3T. A SMS DWI sequence with CAIPIRINHA unaliasing technique (acceleration factors 2/3, denoted AF2/3) was compared to standard DWI-EPI (AF1). Four schemes were evaluated: (i) reducing TA, (ii) keeping TA identical with increasing number of averages, (iii) increasing number of slices with identical TA (iv) increasing number of b-values for IVIM. Acquisition schemes i-iii were evaluated qualitatively (reader score) and quantitatively (ADC values, SNR). Results: In scheme (i) no differences in SNR were observed (p = 0.321 − 0.038) with reduced TA (AF2 increase in SNR/time 75.6%, AF3 increase SNR/time 102.4%). No SNR improvement was obtained in scheme (ii). Increased SNR/time could be invested in acquisition of more and thinner slices or higher number of b-values. Image quality scores were stable for AF2 but decreased for AF3. Only for AF3, liver ADC values were systematically lower. Conclusion: SMS-DWI of the liver and pancreas provides substantially higher SNR/time, which either may be used for shorter scan time, higher slice resolution or IVIM measurements.

  6. Early diagnosis and severity assessment of acute pancreatitis (AP) using MR elastography (MRE) with spin-echo echo-planar imaging.

    Science.gov (United States)

    Shi, Yu; Liu, Ying; Liu, Yan-Qing; Gao, Feng; Li, Jia-Hui; Li, Qiu-Ju; Guo, Qi-Yong

    2017-11-01

    To evaluate the accuracy of magnetic resonance elastography (MRE) in comparison to contrast-enhanced computed tomography (CE-CT) for early diagnosis and prediction of severity in acute pancreatitis (AP). This cross-sectional prospective study included 76 patients with suspected AP who underwent both CE-CT and 3.0T MRE within 24 hours of hospital admission. Pancreatic stiffness, CT severity index (CTSI), Acute Physiology and Chronic Health Evaluation (APACHE)-II, and Bedside Index for Severity in AP (BISAP) scores were comparatively evaluated using data from the first 24 hours of admission, and diagnosis and severity of AP were confirmed according to the revised Atlanta Classification (2012). The accuracy of MRE for predicting disease severity was compared with that of CE-CT and the clinical scoring systems using area under the receiver-operating curve (AUC) analysis. AP was confirmed in 56/76 patients (73.7%). Pancreatic stiffness values of >1.47 kPa showed significantly better diagnostic performance than CE-CT (AUC: 0.993 vs. 0.818, P AP. The accuracy of pancreatic stiffness >2.47 kPa was comparable to that of the CTSI, APACHE-II and BISAP scores for predicting severe AP (accuracy = 85.5%, 75.0%, 88.2%, and 78.9%, respectively). The pairwise comparisons were not significant after Bonferroni correction (P AP. We recommend MRE at hospital admission for initial evaluation of AP. 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2017;46:1311-1319. © 2017 International Society for Magnetic Resonance in Medicine.

  7. Evaluation of white matter lesions by diffusion tensor MR imaging. Preliminary experience

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, Takeharu; Ohtomo, Kuni [Tokyo Univ. (Japan). Faculty of Medicine; Aoki, Shigeki; Ishigame, Keiichi; Araki, Tsutomu; Kabasawa, Hiroyuki

    2000-11-01

    Diffusion tensor imaging (DTI) represents diffusion anisotropy or directional difference of water diffusion. We preliminarily studied normal volunteers and patients with DTI using single-shot echo planar imaging. DTI was performed easily within a few minutes in all examinations. Fractional anisotropy of white matter lesions was decreased in pathological conditions. DTI is considered to be useful to estimate white matter of the brain, especially in diagnosis of myelination, secondary degeneration, and demyelinating and degenerative disease. (author)

  8. Diffusion-weighted MRI of the cervical spinal cord using a single-shot fast spin-echo technique: findings in normal subjects and in myelomalacia

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiya, K.; Katase, S.; Fujikawa, A.; Hachiya, J. [Department of Radiology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka, 181-8611, Tokyo (Japan); Kanazawa, H. [Toshiba Corporation, 1-1-1 Shibaura, Minato-ku, 105-8001, Tokyo (Japan); Yodo, K. [Toshiba Medical Systems, 3-26-5 Hongo, Bunkyo-ku, 113-8456, Tokyo (Japan)

    2003-02-01

    We have implemented a new diffusion-weighted MRI (DWI) sequence based on the single-shot fast spin-echo technique. We hypothesised that this would add information to conventional MRI for diagnosis of lesions of the cervical spinal cord. DWI was performed using a technique in which echo collection after the application of motion-probing gradients was done in the same manner as in the single-shot fast spin-echo technique. We first imaged six healthy volunteers to demonstrate the cervical spinal cord using the sequence. Then we applied the sequence to 12 patients with cervical myelomalacia due to chronic cord compression. The spinal cord was well seen in all subjects without the distortion associated with echo-planar DWI. In the patients, lesions appeared as areas of low- or isointense signal on DWI. Calculated apparent diffusion coefficients of the lesions (3.30{+-}0.38 x 10{sup -3} mm{sup 2}/s) were significantly higher than those of normal volunteers (2.26{+-}0.08 x 10{sup -3} mm{sup 2}/s). Increased diffusion in areas of cervical myelomalacia, suggesting irreversible damage, can be detected using this technique. (orig.)

  9. Imaging of the normal and abnormal pancreaticobiliary system with single-shot MR cholangiopancreatography: a pictorial review

    International Nuclear Information System (INIS)

    Little, A. F.; Smith, P.J.; Lee, W.K.; Hennessy, O.F.; Lourensz, M.E.; Desmond, P.V.; Banting, S.W.

    1999-01-01

    Magnetic resonance cholangiopancreatography (MRCP) is a rapidly evolving non-invasive imaging modality that produces images of the pancreatic duct and binary tree without the need for intravenous or oral contrast. The images are equivalent to those from endoscopic retrograde cholangiopancreatography (ERCP), but the non-invasive acquisition avoids the morbidity and mortality associated with diagnostic ERCP. Magnetic resonance cholangiopancreatography is indicated in patients who require only a diagnostic ERCP, who fail an ERCP or who are unable to undergo ERCP due to altered post-surgical anatomy. Other evolving indications include triaging of patients with obstructive jaundice into percutaneous or endoscopic management drainage pathways depending on the site, length and nature of the duct obstruction, thereby potentially decreasing the number of failed or unsuccessful ERCP. Preoperative identification of anomalous binary anatomy and choledocholithiasis prior to laparoscopic cholecystectomy promise to modify the pre-operative and operative management of the patient in order to minimize the risk of duct injury and unnecessary intra-operative dissection and cholangiography. The advantages of the technique include its non-invasiveness, the absence of contrast administration, its relative operator independence and the ability to evaluate both sides of an obstructed duct, thereby accurately evaluating stricture morphology and length. The disadvantages of MRCP compared to ERCP include its lack of an immediate therapeutic solution to duct obstruction, procedural cost, unit availability and the inability to evaluate patients with pacemakers or ferromagnetic implants. Copyright (1999) Blackwell Science Pty Ltd

  10. Faster pediatric 3-T abdominal magnetic resonance imaging: comparison between conventional and variable refocusing flip-angle single-shot fast spin-echo sequences.

    Science.gov (United States)

    Ruangwattanapaisarn, Nichanan; Loening, Andreas M; Saranathan, Manojkumar; Litwiller, Daniel V; Vasanawala, Shreyas S

    2015-06-01

    Single-shot fast spin echo (SSFSE) is particularly appealing in pediatric patients because of its motion robustness. However radiofrequency energy deposition at 3 tesla forces long pauses between slices, leading to longer scans, longer breath-holds and more between-slice motion. We sought to learn whether modulation of the SSFSE refocusing flip-angle train could reduce radiofrequency energy deposition without degrading image quality, thereby reducing inter-slice pauses and overall scan times. We modulated the refocusing flip-angle train for SSFSE to minimize energy deposition while minimizing blurring and motion-related signal loss. In a cohort of 50 consecutive patients (25 boys, mean age 5.5 years, range 1 month to 17 years) referred for abdominal MRI we obtained standard SSFSE and variable refocusing flip-angle (vrfSSFSE) images and recorded sequence scan times. Two readers independently scored the images in blinded, randomized order for noise, tissue contrast, sharpness, artifacts and left lobe hepatic signal uniformity on a four-point scale. The null hypothesis of no difference between SSFSE and vrfSSFSE image-quality was assessed with a Mann-Whitney U test, and the null hypothesis of no scan time difference was assessed with the paired t-test. SSFSE and vrfSSFSE mean acquisition times were 54.3 and 26.2 s, respectively (P-value <0.0001). For each reader, SSFSE and vrfSSFSE noise, tissue contrast, sharpness and artifacts were not significantly different (P-values 0.18-0.86). However, SSFSE had better left lobe hepatic signal uniformity (P < 0.01, both readers). vrfSSFSE is twice as fast as SSFSE, with equivalent image quality with the exception of left hepatic lobe signal heterogeneity.

  11. Faster pediatric 3-T abdominal magnetic resonance imaging: comparison between conventional and variable refocusing flip-angle single-shot fast spin-echo sequences

    International Nuclear Information System (INIS)

    Ruangwattanapaisarn, Nichanan; Loening, Andreas M.; Saranathan, Manojkumar; Vasanawala, Shreyas S.; Litwiller, Daniel V.

    2015-01-01

    Single-shot fast spin echo (SSFSE) is particularly appealing in pediatric patients because of its motion robustness. However radiofrequency energy deposition at 3 tesla forces long pauses between slices, leading to longer scans, longer breath-holds and more between-slice motion. We sought to learn whether modulation of the SSFSE refocusing flip-angle train could reduce radiofrequency energy deposition without degrading image quality, thereby reducing inter-slice pauses and overall scan times. We modulated the refocusing flip-angle train for SSFSE to minimize energy deposition while minimizing blurring and motion-related signal loss. In a cohort of 50 consecutive patients (25 boys, mean age 5.5 years, range 1 month to 17 years) referred for abdominal MRI we obtained standard SSFSE and variable refocusing flip-angle (vrfSSFSE) images and recorded sequence scan times. Two readers independently scored the images in blinded, randomized order for noise, tissue contrast, sharpness, artifacts and left lobe hepatic signal uniformity on a four-point scale. The null hypothesis of no difference between SSFSE and vrfSSFSE image-quality was assessed with a Mann-Whitney U test, and the null hypothesis of no scan time difference was assessed with the paired t-test. SSFSE and vrfSSFSE mean acquisition times were 54.3 and 26.2 s, respectively (P-value <0.0001). For each reader, SSFSE and vrfSSFSE noise, tissue contrast, sharpness and artifacts were not significantly different (P-values 0.18-0.86). However, SSFSE had better left lobe hepatic signal uniformity (P < 0.01, both readers). vrfSSFSE is twice as fast as SSFSE, with equivalent image quality with the exception of left hepatic lobe signal heterogeneity. (orig.)

  12. Faster pediatric 3-T abdominal magnetic resonance imaging: comparison between conventional and variable refocusing flip-angle single-shot fast spin-echo sequences

    Energy Technology Data Exchange (ETDEWEB)

    Ruangwattanapaisarn, Nichanan [Mahidol University, Department of Diagnostic and Therapeutic Radiology, Ramathibodi Hospital, Bangkok (Thailand); Stanford University, LPCH Department of Radiology, Stanford, CA (United States); Loening, Andreas M.; Saranathan, Manojkumar; Vasanawala, Shreyas S. [Stanford University, LPCH Department of Radiology, Stanford, CA (United States); Litwiller, Daniel V. [GE Healthcare, Rochester, MN (United States)

    2015-06-15

    Single-shot fast spin echo (SSFSE) is particularly appealing in pediatric patients because of its motion robustness. However radiofrequency energy deposition at 3 tesla forces long pauses between slices, leading to longer scans, longer breath-holds and more between-slice motion. We sought to learn whether modulation of the SSFSE refocusing flip-angle train could reduce radiofrequency energy deposition without degrading image quality, thereby reducing inter-slice pauses and overall scan times. We modulated the refocusing flip-angle train for SSFSE to minimize energy deposition while minimizing blurring and motion-related signal loss. In a cohort of 50 consecutive patients (25 boys, mean age 5.5 years, range 1 month to 17 years) referred for abdominal MRI we obtained standard SSFSE and variable refocusing flip-angle (vrfSSFSE) images and recorded sequence scan times. Two readers independently scored the images in blinded, randomized order for noise, tissue contrast, sharpness, artifacts and left lobe hepatic signal uniformity on a four-point scale. The null hypothesis of no difference between SSFSE and vrfSSFSE image-quality was assessed with a Mann-Whitney U test, and the null hypothesis of no scan time difference was assessed with the paired t-test. SSFSE and vrfSSFSE mean acquisition times were 54.3 and 26.2 s, respectively (P-value <0.0001). For each reader, SSFSE and vrfSSFSE noise, tissue contrast, sharpness and artifacts were not significantly different (P-values 0.18-0.86). However, SSFSE had better left lobe hepatic signal uniformity (P < 0.01, both readers). vrfSSFSE is twice as fast as SSFSE, with equivalent image quality with the exception of left hepatic lobe signal heterogeneity. (orig.)

  13. Pin-hole array production and detailed data analysis for advanced single-shot X-ray imaging of laboratory plasmas

    Science.gov (United States)

    Levato, T.; Labate, L.; Pathak, N. C.; Cecchetti, C.; Koester, P.; Di Fabrizio, E.; Delogu, P.; Giulietti, A.; Giulietti, D.; Gizzi, L. A.

    2010-11-01

    Laser produced plasmas offer the unique opportunity to investigate physical mechanisms working at extremely high field in pulsed regime [1] (Gizzi et al., 2009). Future large scale infrastructure like HiPER and ELI may open new frontiers of knowledge in this way. Technologies needed for improving diagnostic in this field have a strong impact on a wide range of multi-disciplinary applications as for compact plasma-based accelerators [1,2] (Gizzi et al., 2009; Betti et al., 2009) laser fusion oriented experiments, three-dimensional microscopy and lithography. As an example the X-ray imaging, being a powerful diagnostic tool for deep investigation on different variety of laser produced plasma, has obtained a grooving effort in recent years. Large scale facilities working in single-pulse regime for laser fusion oriented experiments have evidenced the necessity to obtain spectrally resolved X-ray images of produced plasmas in a single shot. By combining the charge coupled devices (CCD) based single-photon detection technique with a pin-hole array (PHA) a new diagnostic technique was developed, as shown in recent experiments related to the European HiPER project [3] (Labate et al., 2009). Here we qualitatively describe the PHA production process on a heavy metal substrate by means of SEM images that show an internal diameter on the micrometer scale and an aspect ratio of about 20. The characterization of the X-ray contrast up to 90 keV is presented. The data analysis of the X-ray photons interaction on CCD, for spectrum reconstruction up to high energy, is described [4] (Levato et al., 2008).

  14. Pin-hole array production and detailed data analysis for advanced single-shot X-ray imaging of laboratory plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Levato, T., E-mail: tadzio.levato@lnf.infn.i [FLAME, Laboratori Nazionali di Frascati (LNF), Via E. Fermi 40, 00044 Frascati (Italy); Labate, L.; Pathak, N.C.; Cecchetti, C.; Koester, P. [ILIL, Consiglio Nazionale delle Ricerche (CNR), Pisa (Italy); Di Fabrizio, E. [BIONEM, Campus Magna Graecia University of Catanzaro (UMG) (Italy); Delogu, P. [University of Pisa, Department of Physics (Italy); Giulietti, A. [ILIL, Consiglio Nazionale delle Ricerche (CNR), Pisa (Italy); Giulietti, D. [University of Pisa, Department of Physics (Italy); Gizzi, L.A. [ILIL, Consiglio Nazionale delle Ricerche (CNR), Pisa (Italy)

    2010-11-11

    Laser produced plasmas offer the unique opportunity to investigate physical mechanisms working at extremely high field in pulsed regime (Gizzi et al., 2009). Future large scale infrastructure like HiPER and ELI may open new frontiers of knowledge in this way. Technologies needed for improving diagnostic in this field have a strong impact on a wide range of multi-disciplinary applications as for compact plasma-based accelerators (Gizzi et al., 2009; Betti et al., 2009) laser fusion oriented experiments, three-dimensional microscopy and lithography. As an example the X-ray imaging, being a powerful diagnostic tool for deep investigation on different variety of laser produced plasma, has obtained a grooving effort in recent years. Large scale facilities working in single-pulse regime for laser fusion oriented experiments have evidenced the necessity to obtain spectrally resolved X-ray images of produced plasmas in a single shot. By combining the charge coupled devices (CCD) based single-photon detection technique with a pin-hole array (PHA) a new diagnostic technique was developed, as shown in recent experiments related to the European HiPER project (Labate et al., 2009). Here we qualitatively describe the PHA production process on a heavy metal substrate by means of SEM images that show an internal diameter on the micrometer scale and an aspect ratio of about 20. The characterization of the X-ray contrast up to 90 keV is presented. The data analysis of the X-ray photons interaction on CCD, for spectrum reconstruction up to high energy, is described (Levato et al., 2008).

  15. Improved focal liver lesion detection: comparison of single-shot diffusion-weighted echoplanar and single-shot T-2 weighted turbo spin echo techniques

    NARCIS (Netherlands)

    Coenegrachts, K.; Delanote, J.; ter Beek, L.; Haspeslagh, M.; Bipat, S.; Stoker, J.; van Kerkhove, F.; Steyaert, L.; Rigauts, H.; Casselman, J. W.

    2007-01-01

    The purpose of this study was to compare diffusion-weighted respiratory-triggered single-shot spin echo echoplanar imaging (SS SE-EPI) sequence using four b-values (b=0, b=20, b=300, b=800 s mm(-2)) and single-shot T-2 weighted turbo spin echo (T2W SS TSE) in patients with focal liver lesions, with

  16. Comparative Analysis of Signal Intensity and Apparent Diffusion Coefficient at Varying b-values in the Brain : Diffusion Weighted-Echo Planar Image (T{sub 2} and FLAIR) Sequence

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Jong Kap [Dept. of Radiology, Cheomdan Medical Center, Gwangju (Korea, Republic of); Im, Jung Yeol [Dept. of Digital Management Information Graduate School of Nambu Univesity, Gwangju (Korea, Republic of)

    2009-09-15

    Diffusion-weighted imaging (DWI) has been demonstrated to be a practical method for the diagnosis of various brain diseases such as acute infarction, brain tumor, and white matter disease. In this study, we used two techniques to examine the average signal intensity (SI) and apparent diffusion coefficient (ADC) of the brains of patients who ranged in age from 10 to 60 years. Our results indicated that the average SI was the highest in amygdala (as derived from DWI), whereas that in the cerebrospinal fluid was the lowest. The average ADC was the highest in the cerebrospinal fluid, whereas the lowest measurement was derived from the pons. The average SI and ADC were higher in T{sub 2}-DW-EPI than in FLAIR-DW-EPI. The higher the b-value, the smaller the average difference in both imaging techniques; the lower the b-value, the greater the average difference. Also, comparative analysis of the brains of patients who had experienced cerebral infarction showed no distinct lesion in the general MR image over time. However, there was a high SI in apparent weighted images. Analysis of other brain diseases (e.g., bleeding, acute, subacute, chronic infarction) indicated SI variance in accordance with characteristics of the two techniques. The higher the SI, the lower the ADC. Taken together, the value of SI and ADC in accordance with frequently occurring areas and various brain disease varies based on the b-value and imaging technique. Because they provide additional useful information in the diagnosis and treatment of patients with various brain diseases through signal recognition, the proper imaging technique and b-value are important for the detection and interpretation of subacute stroke and other brain diseases.

  17. Echo planar diffusion and perfusion MRI detect pathophysiological heterogeneity in cerebral contusion

    International Nuclear Information System (INIS)

    Aoyama, Naoki; Mori, Tatsuro; Maeda, Takeshi; Kawamata, Tatsuro; Katayama, Yoichi

    2000-01-01

    Cerebral contusions have heterogeneous mechanisms of early edema formation and frequently cause elevation of ICP and resultant clinical deterioration. In the present study, in order to investigate the mechanisms of early contusion edema, diffusion-weighted imaging, apparent diffusion coefficient (ADC) mapping and perfusion imaging were performed using 1.5 T echo planar imaging (EPI) in patients with cerebral contusion. On diffusion image within 24 hours post-trauma, the central area of the contusion were demonstrated as low intensity. In contrast, the peripheral area had high intensity. The ADC value increased in the central area and decreased in peripheral area. During 24-48 hours post-trauma, a crescent-shaped zone of very high ADC value was observed at the border between these two areas. These results indicate that, in early phase of cerebral contusion, cytotoxic edema is predominantly present in the peripheral area and edema fluid accumulates at the border between central and peripheral area of cerebral contusion 24-48 hours post-trauma. Perfusion imaging demonstrates wide spread CBF depression within the cerebral contusion. Diffusion and perfusion image using EPI are useful for evaluating heterogeneous mechanisms of early edema formation and CBF changes in the acute phase of cerebral contusion. (author)

  18. SSH-EPI diffusion-weighted MR imaging of the spine with low b values: is it useful in differentiating malignant metastatic tumor infiltration from benign fracture edema?

    Science.gov (United States)

    Oztekin, Ozgur; Ozan, Ebru; Hilal Adibelli, Zehra; Unal, Gökhan; Abali, Yusuf

    2009-07-01

    Conventional MR sequences are sometimes not helpful in differentiating benign from pathologic fractures. Our aim was to evaluate the usefulness of single-shot echo-planar imaging sequences (diffusion-weighted imaging (DWI)/SSH-EPI) with low b value in differentiating malignant metastatic tumor infiltration of vertebral bone marrow from benign vertebral fracture edema. A total of 47 patients, 20 with benign fractures and 27 with tumor infiltration, were included in this prospective study. Diffusion-weighted MR images were obtained by single-shot echo-planar imaging technique with diffusion gradient (b = 300 s/mm2; TR/TE, 1,400/100), using a 1.5 T MR scanner. T1- and T2-weighted images and short inversion time inversion-recovery images were available for all 64 lesions. The lesions on DWI/SSH-EPI were categorized as having hypo-, iso-, or hyperintense signal intensity relative to normal vertebrae by two experienced radiologists. We evaluated signal intensity patterns on DWI/SSH-EPI in 64 lesions, which showed low signal intensity on T1-weighted images in both benign fractures and metastasis. With the exception of sclerotic metastases in two patients, malignant metastatic tumor infiltration was hyperintense with respect to normal bone marrow on diffusion-weighted images; all but four benign vertebral fractures were isointense with respect to normal bone marrow. Single-shot echo-planar imaging sequences (DWI/SSH-EPI) with low b value provided excellent distinction between metastatic tumor infiltration and benign vertebral fracture edema. Hyperintense signal intensity on DWI/SSH-EPI was highly specific for the diagnosis of metastatic tumor infiltration of the spine.

  19. Strategies to improve phase-stability of ultrafast swept source optical coherence tomography for single shot imaging of transient mechanical waves at 16 kHz frame rate

    Energy Technology Data Exchange (ETDEWEB)

    Song, Shaozhen; Wei, Wei; Hsieh, Bao-Yu; Pelivanov, Ivan; O' Donnell, Matthew [Department of Bioengineering, University of Washington, Seattle, Washington 98195 (United States); Shen, Tueng T.; Wang, Ruikang K., E-mail: wangrk@uw.edu [Department of Bioengineering, University of Washington, Seattle, Washington 98195 (United States); Department of Ophthalmology, University of Washington, Seattle, Washington 98104 (United States)

    2016-05-09

    We present single-shot phase-sensitive imaging of propagating mechanical waves within tissue, enabled by an ultrafast optical coherence tomography (OCT) system powered by a 1.628 MHz Fourier domain mode-locked (FDML) swept laser source. We propose a practical strategy for phase-sensitive measurement by comparing the phases between adjacent OCT B-scans, where the B-scan contains a number of A-scans equaling an integer number of FDML buffers. With this approach, we show that micro-strain fields can be mapped with ∼3.0 nm sensitivity at ∼16 000 fps. The system's capabilities are demonstrated on porcine cornea by imaging mechanical wave propagation launched by a pulsed UV laser beam, promising non-contact, real-time, and high-resolution optical coherence elastography.

  20. Comparison of respiratory-triggered 3-D fast spin-echo and single-shot fast spin-echo radial slab MR cholangiopancreatography images in children

    International Nuclear Information System (INIS)

    Chavhan, Govind B.; Almehdar, Abeer; Gupta, Sumeet; Moineddin, Rahim; Babyn, Paul S.

    2013-01-01

    The two most commonly performed magnetic resonance cholangiopancreatography (MRCP) sequences, 3-D fast spin-echo (3-D FSE) and single-shot fast spin-echo radial slabs (radial slabs), have not been compared in children. The purpose of this study was to compare 3-D FSE and radial slabs MRCP sequences on a 3-T scanner to determine their ability to show various segments of pancreaticobiliary tree and presence of artifacts in children. We reviewed 79 consecutive MRCPs performed in 74 children on a 3-T scanner. We noted visibility of major ducts on 3-D FSE and radial slabs. We noted the order of branching of ducts in the right and left hepatic ducts and the degree of visibility of the pancreatic duct. Statistical analysis was performed using McNemar and signed rank tests. There was no significant difference in the visibility of major bile ducts and the order of branching in the right hepatic lobe between sequences. A higher order of branching in the left lobe was seen on radial slabs than 3-D FSE (mean order of branching 2.82 versus 2.27; P-value = 0.0002). The visibility of pancreatic duct was better on radial slabs as compared to 3-D FSE (mean value of 1.53 vs. 0.90; P-value < 0.0001). 3-D FSE sequence was artifact-free in 25/79 (31.6%) MRCP exams as compared to radial slabs, which were artifact-free in 18/79 (22.8%) MRCP exams (P-value = 0.0001). There is no significant difference in the visibility of major bile ducts between 3-D FSE and radial slab MRCP sequences at 3-T in children. However, radial slab MRCP shows a higher order of branching in the left hepatic lobe and superior visibility of the pancreatic duct than 3-D FSE. (orig.)

  1. Echo-planar MR cerebral blood volume mapping of glomas. Clinical utility

    International Nuclear Information System (INIS)

    Aronen, H.J.; Univ. Central Hospital, Helsinki; Glass, J.; Pardo, F.S.; Belliveau, J.W.; Gruber, M.L.; Buchbinder, B.R.; Gazit, I.E.; Linggood, R.M.; Fischman, A.J.; Rosen, F.S.; Hochberg, F.H.

    1995-01-01

    Neovascularization is a common phenomenon in gliomas. MR imaging cerebral blood volume (CBV) mapping utilizes ultrafast echo-planar imaging and simultaneous use of gadolinium-based contrast material. To determine the utility of MR CBV mapping in the clinical evaluation of gliomas, we followed 15 patients with serial studies. This technique provided functional information that was not evident with conventional CT or MR imaging. Low-grade tumors demonstrated homogeneously low CBV, while high-grade tumors often showed areas of both high and low CBV. The maximum tumor CBV/white matter ratio was compared between low- (n=3) and high-grade gliomas (n=5) in patients without previous treatment and with histologic verification (n=8) and was significantly higher in high-grade gliomas (p<0.01), High CBV foci in nonenhancing tumor areas were present in 2 cases. The distinction between radiation necrosis and active tumor could be made correctly in 3 of 4 cases. The information provided by MR CBV mapping has the potential to be an adjunct in the clinical care of glioma patients. (orig.)

  2. Single-shot 35 fs temporal resolution electron shadowgraphy

    Energy Technology Data Exchange (ETDEWEB)

    Scoby, C. M.; Li, R. K.; Threlkeld, E.; To, H.; Musumeci, P. [Department of Physics and Astronomy, UCLA, Los Angeles, California 90095 (United States)

    2013-01-14

    We obtain single-shot time-resolved shadowgraph images of the electromagnetic fields resulting from the interaction of a high intensity ultrashort laser pulse with a metal surface. Using a high brightness relativistic electron beam and a high streaking speed radiofrequency deflector, we report <35 fs temporal resolution enabling a direct visualization of the retarded-time dominated field evolution which follows the laser-induced charge emission. A model including the finite signal propagation speed well reproduces the data and yields measurements of fundamental parameters in short pulse laser-matter interaction such as the amount of emitted charge and the emission time scale.

  3. Diffusion tensor trace mapping in normal adult brain using single-shot EPI technique: A methodological study of the aging brain

    International Nuclear Information System (INIS)

    Chen, Z.G.; Hindmarsh, T.; Li, T.Q.

    2001-01-01

    Purpose: To quantify age-related changes of the average diffusion coefficient value in normal adult brain using orientation-independent diffusion tensor trace mapping and to address the methodological influences on diffusion quantification. Material and Methods: Fifty-four normal subjects (aged 20-79 years) were studied on a 1.5-T whole-body MR medical unit using a diffusion-weighted single-shot echo-planar imaging technique. Orientation-independent diffusion tensor trace maps were constructed for each subject using diffusion-weighted MR measurements in four different directions using a tetrahedral gradient combination pattern. The global average (including cerebral spinal fluid) and the tissue average of diffusion coefficients in adult brains were determined by analyzing the diffusion coefficient distribution histogram for the entire brain. Methodological influences on the measured diffusion coefficient were also investigated by comparing the results obtained using different experimental settings. Results: Both global and tissue averages of the diffusion coefficient are significantly correlated with age (p<0.03). The global average of the diffusion coefficient increases 3% per decade after the age of 40, whereas the increase in the tissue average of diffusion coefficient is about 1% per decade. Experimental settings for self-diffusion measurements, such as data acquisition methods and number of b-values, can slightly influence the statistical distribution histogram of the diffusion tensor trace and its average value. Conclusion: Increased average diffusion coefficient in adult brains with aging are consistent with findings regarding structural changes in the brain that have been associated with aging. The study also demonstrates that it is desirable to use the same experimental parameters for diffusion coefficient quantification when comparing between different subjects and groups of interest

  4. Single-shot two-dimensional full-range optical coherence tomography achieved by dispersion control

    NARCIS (Netherlands)

    Witte, S.; Baclayon, M.; Peterman, E.J.G.; Toonen, R.F.G.; Mansvelder, H.D.; Groot, M.L.

    2009-01-01

    We present a full-range Fourier-domain optical coherence tomography (OCT) system that is capable of acquiring two-dimensional images of living tissue in a single shot. By using line illumination of the sample in combination with a two-dimensional imaging spectrometer, 1040 depth scans are performed

  5. A second-order autocorrelator for single-shot measurement of ...

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    mental and second-harmonic frequency respectively, and 2α is the crossover angle of the beams inside the ... dispersion (GVD) effects in the crystal and spatial resolution of the imaging system. In the case ... Figure 3a shows the image of SH radiation from the KDP crystal corresponding to the single- shot operation of the ...

  6. Single-shot self-interference incoherent digital holography using off-axis configuration.

    Science.gov (United States)

    Hong, Jisoo; Kim, Myung K

    2013-12-01

    We propose a single-shot incoherent holographic imaging technique that adopts self-interference incoherent digital holography (SIDH) with slight tilt of the plane mirror in the optical configuration. The limited temporal coherence length of the illumination leads the guide-star hologram of the proposed system to have a Gaussian envelope of elliptical ring shape. The observation shows that the reconstruction by cross correlation with the guide-star hologram achieves better quality than the usual propagation methods. Experimentally, we verify that the hologram and 3D reconstruction can be implemented incoherently with the proposed single-shot off-axis SIDH.

  7. The single-shot opto-digitizer

    International Nuclear Information System (INIS)

    Nail, M.; Gibert, Ph.

    2000-01-01

    Laser-plasma experiments need to measure signals provided either by X-ray, photonic or neutronic detector. The measurement should have 50 GHz bandwidth and up to several hundred of Giga-Hertz for sub picosecond plasmas. For this purpose, a 35 GHz single shot opto-digitizer (10 ps risetime) has been studied and built. The device is made up of a 50 ohms microstrip propagation line, periodically lined by 100 sampled gates. The propagation line is long enough to measure a 400 ps duration. The sampling rate is 250 Gsa/s (every 4 ps). The sampled gates are made with fast recombining photo-material and turn on by a subpicosecond laser pulse which is synchronized exactly with the analysed phenomena. Every gate is recording to a storing capacitor. After the recording, every capacitor charge is needed to built the signal that was displayed on the propagation line. The dynamic range of measurement is 47 for the entire device. The device can measure positive or negative signals from 1.5 to 70 Volts. To increase the bandwidth, two another kinds of opto-digitizer were studied: one is a buried stripline with 56 GHz band width, the other a 70 GHz coplanar transmission line. For the purpose of subpicosecond plasmas, a 30 coplanar waveguide opto-digitizer was studied. Characteristics are as followed: window of measurement 40 ps, sampling rate 1 ps, bandwidth 230 GHz. Finally, a bundle of optical fibers was used to propagate the laser beam on semiconductor gates. If the gates are lighted at the same time, i.e. if the optical fibers have the same length, we get a simultaneous addressing. By using different lengths of optical fibers, we can do a sequential addressing. So, the sampling rate becomes a combination of the distance between two adjacent sampled channels, and the difference in length of optical fibers. (author)

  8. Detection of hyperacute parenchymal hemorrhage of the brain using echo-planar T2{sup *}-weighted and diffusion-weighted MRI

    Energy Technology Data Exchange (ETDEWEB)

    Wiesmann, M. [Dept. of Radiology, Medizinische Universitaet zu Luebeck (Germany); Mayer, T.E.; Yousry, I.; Brueckmann, H. [Dept. of Neuroradiology, Klinikum Grosshadern, Ludwig-Maximilians-Universitaet, Muenchen (Germany); Hamann, G.F. [Dept. of Neurology, Klinikum Grosshadern, Ludwig-Maximilians-Universitaet, Muenchen (Germany)

    2001-05-01

    We investigated the usefulness of echo-planar imaging (EPI) as well as T2{sup *}-weighted and diffusion-weighted MRI (DWI) to identify hyperacute hemorrhage (within 24 h after ictus) in the brain. Seven patients were examined 3.5 to 24 h after onset of symptoms using a whole-body 1.5-T MR system. Two diffusion-weighted sequences were run to obtain isotropic and anisotropic diffusion images. Apparent diffusion coefficients (ADC) were calculated from the isotropic diffusion images. All DWI images as well as the T2*-weighted EPI images showed the hematomas as either discrete, deeply hypointense homogeneous lesions, or as lesions of mixed signal intensity containing hypointense areas. We conclude that even in the early phase after hemorrhage, sufficient amounts of paramagnetic deoxyhemoglobin are present in intracerebral hemorrhages to cause hypointensity on EPI T2{sup *}-weighted and DWI images; thus, use of ultrafast EPI allows identification of intracerebral hemorrhage. (orig.)

  9. MR cholangiopancreatography of pancreaticobiliary diseases: Comparison of single-shot RARE and multislice HASTE sequences

    Energy Technology Data Exchange (ETDEWEB)

    Morrin, Martina M.; Farrell, Richard J.; McEntee, Gerry; MacMathuna, Padraic; Stack, John P.; Murrah, John G

    2000-11-01

    AIMS: We prospectively compared two breath-hold magnetic resonance cholangiopancreatography (MRCP) sequences: single-shot rapid acquisition with relaxation enhancement (RARE) and multislice half-Fourier acquisition single-shot turbo spin echo (HASTE) in imaging the pancreaticobiliary system. PATIENTS AND METHODS: The diagnostic accuracy of single-shot RARE and multislice HASTE was studied in 34 subjects who had undergone conventional cholangiopancreatography. Overall image quality, duct conspicuity, image artifact, signal intensity and contrast-to-noise ratios were assessed independently by two radiologists who were unaware of the underlying diagnosis. RESULTS: Both sequences had comparable diagnostic accuracy regarding a normal biliary system, choledocholithiasis, extra-hepatic and intra-hepatic strictures. Single-shot RARE was superior to multislice HASTE in diagnosing a normal pancreatic system, pancreatic and intrahepatic duct strictures, while providing significantly better image quality (mean {+-} SE 3.7 {+-} 0.07 vs 3.3 {+-} 0.08: P = 0.02) and significantly less image artifact (mean {+-} SE 3.6 {+-} 0.07 vs 3.2 {+-} 0.08:P = 0.01). Single-shot RARE provided significantly better duct conspicuity regarding the pancreatic duct within the body (2.7 {+-} 0.2 vs 2.1 {+-} 0.2: P = 0.003) and tail (2.4 {+-} 0.2 vs 1.6 {+-} 0.2;P = 0.0001), as well as the intrahepatic ducts (3.0 {+-} 0.1 vs 2.6 {+-} 0.1: P = 0.004) but there was no significant difference regarding the remainder of the biliary tree. CONCLUSION: Single-shot RARE provides superior image quality, duct conspicuity with the added advantage of less image artifact and shorter acquisition time. However, volume averaging can cause common bile duct stones to be missed. Therefore, multislice HASTE sequences should still be acquired if choledocholithiasis is suspected. Larger studies are required to assess the diagnostic efficacy of single-shot RARE sequences in pancreatic duct and intra-hepatic duct disease

  10. Diffusion-weighted MR imaging of the abdomen with pulse triggering

    International Nuclear Information System (INIS)

    Muertz, P.; Pauleit, D.; Traeber, F.; Kreft, B.P.; Schild, H.H.

    2000-01-01

    Purpose: The aim of this work was to reduce the influence of motion on diffusion-weighted MR images of the abdomen by pulse triggering of single-shot sequences. Methods: Five healthy volunteers were examined both without and with finger pulse-triggering of a diffusion-weighted single-shot echo planar MR imaging sequence at 1.5 T. Series of diffusion-weighted images were acquired at different phases of the cardiac cycle by varying the time delay between finger pulse and sequence acquisition. The measurements were repeated three times. The diffusion weighted images were analysed by measuring the signal intensities and by determining the ADC values within the spleen, kidney and liver. Results: The magnitude of motion artifacts on diffusion weighted images shows a strong dependence on the trigger delay. The optimum trigger delay is found to be between 500 and 600 ms. For these values the abdominal organs appear homogeneous on all diffusion weighted images and the strongest signal intensities are detected. At optimum triggering the accuracy of the apparent diffusion coefficients is up to 10 times better than without triggering. Moreover, the standard deviation of the repeated measurements is smaller than 12% for all volunteers and for all organs. Without triggering the standard deviation is larger by a factor of 4 on average. Conclusion: Pulse triggering of single-shot sequences leads to significant reduction of motion related artifacts on diffusion weighted images of the abdomen and provides more accurate and reproducible ADC values. (orig.) [de

  11. Inversion recovery single-shot TurboFLASH for assessment of myocardial infarction at 3 Tesla.

    Science.gov (United States)

    Bauner, Kerstin U; Muehling, Olaf; Wintersperger, Bernd J; Winnik, Eva; Reiser, Maximilian F; Huber, Armin

    2007-06-01

    The aim of the study was to assess the diagnostic accuracy of imaging myocardial infarction with a single-shot inversion recovery turbofast low-angle shot (SS IR turboFLASH) sequence at 3.0 Tesla in comparison with an established segmented inversion recovery turboFLASH sequence at 1.5 Tesla. Fifteen patients with myocardial infarction were examined at a 1.5 Tesla magnetic resonance (MR) System (Avanto, Siemens, Medical Solutions) and at a 3.0 Tesla MR system (TIM Trio, Siemens, Medical Solutions). Imaging delayed enhancement was started 15 minutes after application of contrast material. A SS IR turboFLASH was performed at 3.0 Tesla and compared with a segmented IR turboFLASH sequence at 1.5 and at 3.0 Tesla. The IR turboFLASH sequence at 1.5 Tesla served as reference method. Infarct volumes, contrast/noise ratio (CNR) of infarcted and normal myocardium were compared with the reference method. The Single-Shot IR turboFLASH technique allows imaging 9 slices during a single breath-hold. The CNR between infarction and normal myocardium of the reference method was 6.4 at 1.5 Tesla. The mean value of CNR of the IR turboFLASH sequence was 7.3 at 3.0 Tesla for the single-shot technique and 14.1 at 3.0 Tesla for the segmented technique. No significant difference was found for the CNR values of the reference technique at 1.5 Tesla and the single-shot technique at 3.0 Tesla, however for the comparison of the segmented technique at 1.5 and at 3 Tesla (P = 0.0001). The correlation coefficients of the infarct volumes, determined with the Single-Shot IR turboFLASH and the segmented IR turboFLASH technique at 3.0 compared with the reference method, were r = 0.95 (P < 0.0001) and r = 0.95 (P < 0.0001). The loss of CNR, which is caused by replacement of the segmented technique by the single-shot technique, is completely compensated by the approximately 2-fold CNR increase at the higher field strength. The IR turboFLASH technique at 3.0 Tesla IR can be used as a single-shot technique

  12. Comparison between EPI and HASTE for ultra-fast MR imaging of the human brain

    International Nuclear Information System (INIS)

    Ge, Y.; Korogi, Y.; Sugahara, T.; Shigematsu, Y.; Hirai, T.; Kitajima, M.; Liang, L.; Takahashi, M.; Dai, J.

    2001-01-01

    Our purpose was to evaluate and compare the performance of ultra-fast single-shot T2-weighted sequences: echo-planar imaging (EPI) versus half-Fourier single-shot turbo spin-echo (HASTE) and to assess the usefulness of their combined reading. Comparative experiments on a phantom as well as a prospective clinical study in 47 patients were done. Axial images acquired with the following methods were compared: (a) HASTE; (b) segmented HASTE (s-HASTE); (c) single-shot spin-echo EPI (SE-EPI); and (d) gradient-echo EPI (GRE-EPI). Quantitative and qualitative criteria as well as lesion detectability were analyzed against the ''gold standard'' fast spin-echo (FSE) sequence. For contrast and contrast-to-noise ratio (CNR) between gray and white matter, GRE-EPI was best. The visibility of small markedly hyperintense lesion was best with HASTE and s-HASTE in the clinical study. Small hyperintense lesions were detected equally well with all four sequences, although all performed significantly worse than FSE. The two HASTE variants were better than the EPIs for the extraaxial lesions. The combination of the GRE-EPI and s-HASTE was judged best, and sometimes superior to the FSE image. HASTE or EPI alone cannot substitute for FSE in the screening evaluation of the brain. However, together, EPI and HASTE could provide comparable diagnostic information to that of FSE because their combination compensates for their individual limitations. (orig.)

  13. Single shot high resolution digital holography.

    Science.gov (United States)

    Khare, Kedar; Ali, P T Samsheer; Joseph, Joby

    2013-02-11

    We demonstrate a novel computational method for high resolution image recovery from a single digital hologram frame. The complex object field is obtained from the recorded hologram by solving a constrained optimization problem. This approach which is unlike the physical hologram replay process is shown to provide high quality image recovery even when the dc and the cross terms in the hologram overlap in the Fourier domain. Experimental results are shown for a Fresnel zone hologram of a resolution chart, intentionally recorded with a small off-axis reference beam angle. Excellent image recovery is observed without the presence of dc or twin image terms and with minimal speckle noise.

  14. Normal anatomy of the fetus at MR imaging.

    Science.gov (United States)

    Amin, R S; Nikolaidis, P; Kawashima, A; Kramer, L A; Ernst, R D

    1999-10-01

    Owing to recent advances in magnetic resonance (MR) imaging, the role of obstetric MR imaging has increased in cases in which the results of ultrasonography are equivocal. Fast MR imaging sequences, such as T2-weighted fast spin-echo (SE), half-Fourier single-shot fast SE, 0.5-signal-acquired single-shot fast SE, and echo-planar imaging, have virtually eliminated the need for fetal premedication, with a concomitant improvement in image resolution and diminished blurring. Artifacts related to maternal respiratory motion and fetal motion no longer limit the anatomic detail that can be demonstrated with MR imaging. With such advances in obstetric MR imaging, knowledge of normal fetal anatomy at MR imaging is essential to detect disease in utero. MR imaging can demonstrate fetal anatomy in detail, especially the brain, thorax, abdomen, pelvis, and vasculature. Major developmental structures of the fetus, particularly the cranial nervous system, naso- and oropharynx, lungs, and major abdominal viscera, can be adequately evaluated with targeted fast MR imaging as early as the beginning of the second trimester. However, MR imaging of the heart remains limited. Fetal MR imaging during the first trimester remains controversial secondary to biosafety issues and is limited due to diminutive fetal size.

  15. Rapid MR imaging of the liver. Comparison of twelve techniques for single breath-hold whole volume acquisition

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Jenner, Goeran; Cooper, T.G.; Potchen, E.J.; Ishigaki, Takeo

    1994-01-01

    Twelve magnetic resonance imaging pulse sequences for single breath-hold whole volume acquisition of the liver were evaluated on volunteers. Liver and spleen contrast to noise ratio (C/N), overall image quality, and grade of artifacts were compared. The 12 sequences included T 2 -weighted fast spin echo (FSE) with or without fat suppression (FS), fast multiplanar spoiled gradient recalled imaging (FMPSPGR), fast gradient recalled imaging without preparation pulses (FGR), FGR with inversion recovery preparation pulse nulling the liver or fat (IR-FGR-L and IR-FGR-F), FGR with driven equilibrium preparation pulse (DE-FGR), single shot moderately or heavily T 2 -weighted spin echo echo planar imaging (SE-EPI-mT2 and SE-EPI-hT2), multi-shot moderately T 2 -weighted spin echo echo planar imaging (multi-shot SE-EPI-mT2), inversion recovery EPI, and gradient echo EPI. In the quantitative analysis, FSE + FS showed a significantly higher C/N ratio than the others (p<0.05). In the qualitative evaluation, DE-prepFGR, and single and multi-shot SE-EPI-mT2 had good results, as did FSE and FSE + FS. Further studies should be conducted to determine whether or not these breath-hold sequences can obviate current conventional non-breath-hold sequences. (author)

  16. Single shot diffraction of picosecond 8.7-keV x-ray pulses

    Directory of Open Access Journals (Sweden)

    F. H. O’Shea

    2012-02-01

    Full Text Available We demonstrate multiphoton, single shot diffraction images of x rays produced by inverse Compton scattering a high-power CO_{2} laser from a relativistic electron beam, creating a pulse of 8.7 keV x rays. The tightly focused, relatively high peak brightness electron beam and high photon density from the 2 J CO_{2} laser yielded 6×10^{7} x-ray photons over the full opening angle in a single shot. Single shot x-ray diffraction is performed by passing the x rays though a vertical slit and on to a flat silicon (111 crystal. 10^{2} diffracted photons were detected. The spectrum of the detected x rays is compared to simulation. The diffraction and detection of 10^{2} x rays is a key step to a more efficient time resolved diagnostic in which the number of observed x rays might reach 10^{4}; enabling a unique, flexible x-ray source as a sub-ps resolution diagnostic for studying the evolution of chemical reactions, lattice deformation and melting, and magnetism.

  17. Small Field-of-view single-shot EPI-DWI of the prostate: Evaluation of spatially-tailored two-dimensional radiofrequency excitation pulses.

    Science.gov (United States)

    Attenberger, Ulrike I; Rathmann, Nils; Sertdemir, Metin; Riffel, Philipp; Weidner, Anja; Kannengiesser, Stefan; Morelli, John N; Schoenberg, Stefan O; Hausmann, Daniel

    2016-06-01

    Spatially-tailored (RF) excitation pulses in echo-planar imaging (EPI), combined with a decreased FOV in the phase-encoding direction, enable a reduction of k-space acquisition lines, which shortens the echo train length (ETL) and reduces susceptibility artifacts. The purpose of this study was to evaluate the image quality of a zoomed EPI (z-EPI) sequence in diffusion-weighted imaging (DWI) of the prostate in comparison to a conventional single-shot EPI using single-channel (c-EPI1) and multi-channel (c-EPI2) RF excitation, with and without use of an endorectal coil. 33 consecutive patients (mean age: 61 +/- 9 years; mean PSA: 8.67±6.23 ng/ml) with examinations between 10/2012 and 02/2014 were analyzed in this retrospective study. In 26 of 33 patients the initial multiparametric (mp)-MRI was performed on a whole-body 3T scanner (Magnetom Trio, Siemens, Erlangen, Germany) using an endorectal coil (c (conventional)-EPI1). Zoomed-EPI (Z-EPI) examinations of these patients and a complete mp-MRI protocol including c-EPI2 of 7 additional patients were carried out on another 3T wb MR scanner with two-channel dynamic parallel transmit capability (Magnetom Skyra with TimTX TrueShape, Siemens). For z-EPI, the one-dimensional spatially selective RF excitation pulse was replaced by a two-dimensional RF pulse. Degree of image blur and susceptibility artifacts (0=not present to 3= non-diagnostic), maximum image distortion (mm), apparent diffusion coefficient (ADC) values, as well as overall scan preference were evaluated. SNR maps were generated to compare c-EPI2 and z-EPI. Overall image quality of z-EPI was preferred by both readers in all examinations with a single exception. Susceptibility artifacts were rated significantly lower on z-EPI compared to both other methods (z-EPI vs c-EPI1: p<0.01; z-EPI vs c-EPI2: p<0.01) as well as image blur (z-EPI vs c-EPI1: p<0.01; z-EPI vs c-EPI2: p<0.01). Image distortion was not statistically significantly reduced with z-EPI (z-EPI vs c

  18. Single-shot EPI with Nyquist ghost compensation: Interleaved Dual-Echo with Acceleration (IDEA) EPI

    Science.gov (United States)

    Poser, Benedikt A; Barth, Markus; Goa, Pål-Erik; Deng, Weiran; Stenger, V Andrew

    2012-01-01

    Echo planar imaging is most commonly used for BOLD fMRI, owing to its sensitivity and acquisition speed. A major problem with EPI is Nyquist (N/2) ghosting, most notably at high field. EPI data are acquired under an oscillating readout gradient and hence vulnerable to gradient imperfections such as eddy current delays and off-resonance effects, as these cause inconsistencies between odd and even k-space lines after time reversal. We propose a straightforward and pragmatic method herein termed Interleaved Dual Echo with Acceleration (IDEA) EPI: Two k-spaces (echoes) are acquired under the positive and negative readout lobes, respectively, by performing phase blips only before alternate readout gradients. From these two k-spaces, two almost entirely ghost free images per shot can be constructed, without need for phase correction. The doubled echo train length can be compensated by parallel imaging and/or partial Fourier acquisition. The two k-spaces can either be complex-averaged during reconstruction, which results in near-perfect cancellation of residual phase errors, or reconstructed into separate images. We demonstrate the efficacy of IDEA EPI and show phantom and in vivo images at both 3 and 7 Tesla. PMID:22411762

  19. Deconvolution single shot multibox detector for supermarket commodity detection and classification

    Science.gov (United States)

    Li, Dejian; Li, Jian; Nie, Binling; Sun, Shouqian

    2017-07-01

    This paper proposes an image detection model to detect and classify supermarkets shelves' commodity. Based on the principle of the features directly affects the accuracy of the final classification, feature maps are performed to combine high level features with bottom level features. Then set some fixed anchors on those feature maps, finally the label and the position of commodity is generated by doing a box regression and classification. In this work, we proposed a model named Deconvolutiuon Single Shot MultiBox Detector, we evaluated the model using 300 images photographed from real supermarket shelves. Followed the same protocol in other recent methods, the results showed that our model outperformed other baseline methods.

  20. Partial Fourier techniques in single-shot cross-term spatiotemporal encoded MRI.

    Science.gov (United States)

    Zhang, Zhiyong; Frydman, Lucio

    2018-03-01

    Cross-term spatiotemporal encoding (xSPEN) is a single-shot approach with exceptional immunity to field heterogeneities, the images of which faithfully deliver 2D spatial distributions without requiring a priori information or using postacquisition corrections. xSPEN, however, suffers from signal-to-noise ratio penalties due to its non-Fourier nature and due to diffusion losses-especially when seeking high resolution. This study explores partial Fourier transform approaches that, acting along either the readout or the spatiotemporally encoded dimensions, reduce these penalties. xSPEN uses an orthogonal (e.g., z) gradient to read, in direct space, the low-bandwidth (e.g., y) dimension. This substantially changes the nature of partial Fourier acquisitions vis-à-vis conventional imaging counterparts. A suitable theoretical analysis is derived to implement these procedures, along either the spatiotemporally or readout axes. Partial Fourier single-shot xSPEN images were recorded on preclinical and human scanners. Owing to their reduction in the experiments' acquisition times, this approach provided substantial sensitivity gains vis-à-vis previous implementations for a given targeted in-plane resolution. The physical origins of these gains are explained. Partial Fourier approaches, particularly when implemented along the low-bandwidth spatiotemporal dimension, provide several-fold sensitivity advantages at minimal costs to the execution and processing of the single-shot experiments. Magn Reson Med 79:1506-1514, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  1. Single-shot femtosecond-pulsed phase-shifting digital holography.

    Science.gov (United States)

    Kakue, Takashi; Itoh, Seiya; Xia, Peng; Tahara, Tatsuki; Awatsuji, Yasuhiro; Nishio, Kenzo; Ura, Shogo; Kubota, Toshihiro; Matoba, Osamu

    2012-08-27

    Parallel phase-shifting digital holography is capable of three-dimensional measurement of a dynamically moving object with a single-shot recording. In this letter, we demonstrated a parallel phase-shifting digital holography using a single femtosecond light pulse whose central wavelength and temporal duration were 800 nm and 96 fs, respectively. As an object, we set spark discharge in atmospheric pressure air induced by applying a high voltage to between two electrodes. The instantaneous change in phase caused by the spark discharge was clearly reconstructed. The reconstructed phase image shows the change of refractive index of air was -3.7 × 10(-4).

  2. Single-shot beam profile diagnostics for x-ray FEL's using gas fluorescence

    Science.gov (United States)

    Feng, Yiping; Zhu, Diling; Weninger, Clemens; Alonso-Mori, Roberto; Chollet, Matthieu; Damiani, Daniel S.; Glownia, James M.; Hastings, Jerome B.; Nelson, Silke; Song, Sanghoon; Robert, Aymeric

    2017-06-01

    We report experimental demonstration of capturing single-shot X-ray Free-electron Laser (FEL) beam profiles using gas fluorescence. The measurement was carried out at the Linac Coherent Light Source using 7 keV hard X-rays propagating through ambient air. The nitrogen fluorescence emitted upon the passage of the X-ray FEL beam were imaged using a highly sensitive optical setup, and there was sufficient optical yield that single-shot measurements were feasible. By taking two orthogonal and simultaneous images, the beam trajectory could be determined in a nearly non-invasive manner, and is best suited for photon energies in the soft X-ray regime, where such a diagnostic capability has been largely unavailable previously. The integrated intensity of the images could also serve as a non-invasive intensity monitor, complementary to current implementations of gas- and solidbased monitors. High repetition-rate Free-electron Lasers can greatly benefit from such a new diagnostic tool for eliminating potential thermal damages.

  3. Reference-free unwarping of single-shot spatiotemporally encoded MRI using asymmetric self-refocused echoes acquisition

    Science.gov (United States)

    Chen, Ying; Chen, Song; Zhong, Jianhui; Chen, Zhong

    2015-05-01

    This paper presents a phase evolution rewinding algorithm for correcting the geometric and intensity distortions in single-shot spatiotemporally encoded (SPEN) MRI with acquisition of asymmetric self-refocused echo trains. Using the field map calculated from the phase distribution of the source image, the off-resonance induced phase errors are successfully rewound through deconvolution. The alias-free partial Fourier transform reconstruction helps improve the signal-to-noise ratio of the field maps and the output images. The effectiveness of the proposed algorithm was validated through 7 T MRI experiments on a lemon, a water phantom, and in vivo rat head. SPEN imaging was evaluated using rapid acquisition by sequential excitation and refocusing (RASER) which produces uniform T2 weighting. The results indicate that the new technique can more robustly deal with the cases in which the images obtained with conventional single-shot spin-echo EPI are difficult to be restored due to serious field variations.

  4. Single-shot work extraction in quantum thermodynamics revisited

    Science.gov (United States)

    Wang, Shang-Yung

    2018-01-01

    We revisit the problem of work extraction from a system in contact with a heat bath to a work storage system, and the reverse problem of state formation from a thermal system state in single-shot quantum thermodynamics. A physically intuitive and mathematically simple approach using only elementary majorization theory and matrix analysis is developed, and a graphical interpretation of the maximum extractable work, minimum work cost of formation, and corresponding single-shot free energies is presented. This approach provides a bridge between two previous methods based respectively on the concept of thermomajorization and a comparison of subspace dimensions. In addition, a conceptual inconsistency with regard to general work extraction involving transitions between multiple energy levels of the work storage system is clarified and resolved. It is shown that an additional contribution to the maximum extractable work in those general cases should be interpreted not as work extracted from the system, but as heat transferred from the heat bath. Indeed, the additional contribution is an artifact of a work storage system (essentially a suspended ‘weight’ that can be raised or lowered) that does not truly distinguish work from heat. The result calls into question the common concept that a work storage system in quantum thermodynamics is simply the quantum version of a suspended weight in classical thermodynamics.

  5. Reconstruction strategy for echo planar spectroscopy and its application to partially undersampled imaging

    DEFF Research Database (Denmark)

    Hanson, Lars Peter Grüner; Schaumburg, K; Paulson, O B

    2000-01-01

    or fewer interleaves per acquisition. The method is of particular interest when large bandwidths are needed (e.g., for high field scanning) and for scanners with limited gradient performance. The unavoidable artifacts resulting from undersampling are demonstrated to be acceptable for spectroscopy with long...

  6. Kinematic MRI using short TR single shot fast spin echo (SSFSE) in evaluating swallowing

    International Nuclear Information System (INIS)

    Isogai, Satoshi; Takehara, Yasuo; Isoda, Haruo; Kodaira, Nami; Masunaga, Hatsuko; Ozawa, Fukujirou; Kaneko, Masao; Nozaki, Atsushi; Kabasawa, Hiroyuki

    1999-01-01

    The utility of short TR single shot fast spin echo (SSFSE) MR imaging for evaluating swallowing was determined. Five healthy volunteers underwent kinematic MR imaging of swallowing with a 1.5 T MR scanner using the short TR (300 ms) SSFSE sequence. Twenty phases of sagittal sections were acquired within 6 sec, where the temporal resolution was 300 ms. For oral contrast medium, we used prune yogurt juice with Fe added. The image contrast of short TR SSFSE was found to be somewhere like that of T1-weighted images. In all cases, both the buccal and pharyngeal stages of swallowing were successfully depicted. The Fe-added prune yogurt juice performed as a positive contrast medium and helped determine anatomical structures in the buccal stage. Short TR (300 ms) SSFSE was useful in evaluating swallowing. The combined use of Fe-added prune yogurt juice was helpful in enhancing the surface of the oropharynx. (author)

  7. Single-shot quantitative phase microscopy with color-multiplexed differential phase contrast (cDPC.

    Directory of Open Access Journals (Sweden)

    Zachary F Phillips

    Full Text Available We present a new technique for quantitative phase and amplitude microscopy from a single color image with coded illumination. Our system consists of a commercial brightfield microscope with one hardware modification-an inexpensive 3D printed condenser insert. The method, color-multiplexed Differential Phase Contrast (cDPC, is a single-shot variant of Differential Phase Contrast (DPC, which recovers the phase of a sample from images with asymmetric illumination. We employ partially coherent illumination to achieve resolution corresponding to 2× the objective NA. Quantitative phase can then be used to synthesize DIC and phase contrast images or extract shape and density. We demonstrate amplitude and phase recovery at camera-limited frame rates (50 fps for various in vitro cell samples and c. elegans in a micro-fluidic channel.

  8. Single-shot parallel full range complex Fourier-domain optical coherence tomography

    International Nuclear Information System (INIS)

    Huang Bingjie; Bu Peng; Nan Nan; Wang Xiangzhao

    2011-01-01

    We present a method of parallel full range complex Fourier-domain optical coherence tomography (FDOCT) that is capable of acquiring an artifacts-free two-dimensional (2-D) cross-sectional image, i.e. a full range B-scan tomogram, by a single shot of 2-D CCD camera. This method is based on a spatial carrier technique, in which the spatial carrier-frequency is instantaneously introduced into the 2-D spectral interferogram registered in parallel FDOCT by using a grating-generated reference beam. The spatial-carrier-contained 2-D spectral interferogram is processed through Fourier transformation to obtain a complex 2-D spectral interferogram. From the 2-D complex spectral interferomgram, a full range B-scan tomogram is reconstructed. The principle of our method is confirmed by imaging an onion sample.

  9. Hyperspectral interferometry for single-shot absolute measurement of 3-D shape and displacement fields

    Directory of Open Access Journals (Sweden)

    Ruiz P. D.

    2010-06-01

    Full Text Available We propose a method that we call Hyperspectral Interferometry (HSI to resolve the 2π phase unwrapping problem in the analysis of interferograms recorded with a narrow-band light source. By using a broad-band light source and hyperspectral imaging system, a set of interferograms at different wavenumbers are recorded simultaneously on a high resolution image sensor. These are then assembled to form a three-dimensional intensity distribution. By Fourier transformation along the wavenumber axis, an absolute optical path difference is obtained for each pixel independently of the other pixels in the field of view. As a result, interferograms with spatially distinct regions are analysed as easily as continuous ones. The approach is illustrated with a HSI system to measure 3-D profiles of optically smooth or rough surfaces. Compared to existing profilometers able to measure absolute path differences, the single shot nature of the approach provides greater immunity from environmental disturbance.

  10. Ultrafast MR Imaging in Pediatric Neuroradiology

    International Nuclear Information System (INIS)

    Singh, R.K.; Smith, J.T.; Wilkinson, I.D.; Griffiths, P.D.

    2003-01-01

    Purpose: To compare the diagnostic information obtained from ultrafast MR imaging with standard MR imaging techniques in pediatric neuroradiology. The goal was to judge whether ultrafast methods can be used to replace standard methods and reduce the need for sedation or general anesthesia as a result of the considerably shorter scan times. Material and Methods: Our prospective study involved 125 patients. Routine clinical imaging was performed along with two ultrafast methods. Single shot fast spin echo (SSFSE) was used to give T2-weighted images and an echo planar imaging (EPI) sequence to provide a T1-weighted images. The ultrafast images were presented to an experienced neuro radiologist who was also given the information present on the initial referral card. These reports based on the ultrafast images were then compared with the formal radiologic report made solely on the basis of the standard imaging. Results: The overall sensitivity and specificity for ultrafast imaging when compared to the reference standard were 78% and 98% with positive and negative predictive values of 98% and 76%. Pathologies characterized by small areas of subtle T2 prolongation were difficult or impossible to see on the ultrafast images but otherwise they provided reliable information. Conclusions: This paper demonstrates that ultrafast MR imaging can diagnose many pediatric intracranial abnormalities as well as standard methods. Anatomic resolution limits its capacity to define subtle developmental anomalies and contrast resolution limitations of the ultrafast methods reduce the detection of pathology characterized by subtle T2 prolongation

  11. Multishot versus single-shot pulse sequences in very high field fMRI: a comparison using retinotopic mapping.

    Directory of Open Access Journals (Sweden)

    Jascha D Swisher

    Full Text Available High-resolution functional MRI is a leading application for very high field (7 Tesla human MR imaging. Though higher field strengths promise improvements in signal-to-noise ratios (SNR and BOLD contrast relative to fMRI at 3 Tesla, these benefits may be partially offset by accompanying increases in geometric distortion and other off-resonance effects. Such effects may be especially pronounced with the single-shot EPI pulse sequences typically used for fMRI at standard field strengths. As an alternative, one might consider multishot pulse sequences, which may lead to somewhat lower temporal SNR than standard EPI, but which are also often substantially less susceptible to off-resonance effects. Here we consider retinotopic mapping of human visual cortex as a practical test case by which to compare examples of these sequence types for high-resolution fMRI at 7 Tesla. We performed polar angle retinotopic mapping at each of 3 isotropic resolutions (2.0, 1.7, and 1.1 mm using both accelerated single-shot 2D EPI and accelerated multishot 3D gradient-echo pulse sequences. We found that single-shot EPI indeed led to greater temporal SNR and contrast-to-noise ratios (CNR than the multishot sequences. However, additional distortion correction in postprocessing was required in order to fully realize these advantages, particularly at higher resolutions. The retinotopic maps produced by both sequence types were qualitatively comparable, and showed equivalent test/retest reliability. Thus, when surface-based analyses are planned, or in other circumstances where geometric distortion is of particular concern, multishot pulse sequences could provide a viable alternative to single-shot EPI.

  12. Real time quantitative phase microscopy based on single-shot transport of intensity equation (ssTIE) method

    Science.gov (United States)

    Yu, Wei; Tian, Xiaolin; He, Xiaoliang; Song, Xiaojun; Xue, Liang; Liu, Cheng; Wang, Shouyu

    2016-08-01

    Microscopy based on transport of intensity equation provides quantitative phase distributions which opens another perspective for cellular observations. However, it requires multi-focal image capturing while mechanical and electrical scanning limits its real time capacity in sample detections. Here, in order to break through this restriction, real time quantitative phase microscopy based on single-shot transport of the intensity equation method is proposed. A programmed phase mask is designed to realize simultaneous multi-focal image recording without any scanning; thus, phase distributions can be quantitatively retrieved in real time. It is believed the proposed method can be potentially applied in various biological and medical applications, especially for live cell imaging.

  13. Time-resolved single-shot terahertz time-domain spectroscopy for ultrafast irreversible processes

    Science.gov (United States)

    Zhai, Zhao-Hui; Zhong, Sen-Cheng; Li, Jun; Zhu, Li-Guo; Meng, Kun; Li, Jiang; Liu, Qiao; Peng, Qi-Xian; Li, Ze-Ren; Zhao, Jian-Heng

    2016-09-01

    Pulsed terahertz spectroscopy is suitable for spectroscopic diagnostics of ultrafast events. However, the study of irreversible or single shot ultrafast events requires ability to record transient properties at multiple time delays, i.e., time resolved at single shot level, which is not available currently. Here by angular multiplexing use of femtosecond laser pulses, we developed and demonstrated a time resolved, transient terahertz time domain spectroscopy technique, where burst mode THz pulses were generated and then detected in a single shot measurement manner. The burst mode THz pulses contain 2 sub-THz pulses, and the time gap between them is adjustable up to 1 ns with picosecond accuracy, thus it can be used to probe the single shot event at two different time delays. The system can detect the sub-THz pulses at 0.1 THz-2.5 THz range with signal to noise ratio (SNR) of ˜400 and spectrum resolution of 0.05 THz. System design was described here, and optimizations of single shot measurement of THz pulses were discussed in detail. Methods to improve SNR were also discussed in detail. A system application was demonstrated where pulsed THz signals at different time delays of the ultrafast process were successfully acquired within single shot measurement. This time resolved transient terahertz time domain spectroscopy technique provides a new diagnostic tool for irreversible or single shot ultrafast events where dynamic information can be extracted at terahertz range within one-shot experiment.

  14. Simultaneous single-shot readout of multi-qubit circuits using a traveling-wave parametric amplifier

    Science.gov (United States)

    O'Brien, Kevin

    Observing and controlling the state of ever larger quantum systems is critical for advancing quantum computation. Utilizing a Josephson traveling wave parametric amplifier (JTWPA), we demonstrate simultaneous multiplexed single shot readout of 10 transmon qubits in a planar architecture. We employ digital image sideband rejection to eliminate noise at the image frequencies. We quantify crosstalk and infidelity due to simultaneous readout and control of multiple qubits. Based on current amplifier technology, this approach can scale to simultaneous readout of at least 20 qubits. This work was supported by the Army Research Office.

  15. X-Ray Emission Spectrometer Design with Single-Shot Pump-Probe and Resonant Excitation Capabilities

    Energy Technology Data Exchange (ETDEWEB)

    Spoth, Katherine; /SUNY, Buffalo /SLAC

    2012-08-28

    Core-level spectroscopy in the soft X-ray regime is a powerful tool for the study of chemical bonding processes. The ultrafast, ultrabright X-ray pulses generated by the Linac Coherent Light Source (LCLS) allow these reactions to be studied in greater detail than ever before. In this study, we investigated a conceptual design of a spectrometer for the LCLS with imaging in the non-dispersive direction. This would allow single-shot collection of X-ray emission spectroscopy (XES) measurements with varying laser pump X-ray probe delay or a variation of incoming X-ray energy over the illuminated area of the sample. Ray-tracing simulations were used to demonstrate how the components of the spectrometer affect its performance, allowing a determination of the optimal final design. These simulations showed that the spectrometer's non-dispersive focusing is extremely sensitive to the size of the sample footprint; the spectrometer is not able to image a footprint width larger than one millimeter with the required resolution. This is compatible with a single shot scheme that maps out the laser pump X-ray probe delay in the non-dispersive direction as well as resonant XES applications at normal incidence. However, the current capabilities of the Soft X-Ray (SXR) beamline at the LCLS do not produce the required energy range in a small enough sample footprint, hindering the single shot resonant XES application at SXR for chemical dynamics studies at surfaces. If an upgraded or future beamline at LCLS is developed with lower monochromator energy dispersion the width can be made small enough at the required energy range to be imaged by this spectrometer design.

  16. Efficient Background Segmentation and Seed Point Generation for a Single-Shot Stereo System

    Science.gov (United States)

    Chen, Xiaobo; Xi, Juntong

    2017-01-01

    Single-shot stereo 3D shape measurement is becoming more popular due to its advantages of noise robustness and short acquisition period. One of the key problems is stereo matching, which is related to the efficiency of background segmentation and seed point generation, etc. In this paper, a more efficient and automated matching algorithm based on digital image correlation (DIC) is proposed. The standard deviation of image gradients and an adaptive threshold are employed to segment the background. Scale-invariant feature transform (SIFT)-based feature matching and two-dimensional triangulation are combined to estimate accurate initial parameters for seed point generation. The efficiency of background segmentation and seed point generation, as well as the measuring precision, are evaluated by experimental simulation and real tests. Experimental results show that the average segmentation time for an image with a resolution of 1280 × 960 pixels is 240 milliseconds. The efficiency of seed point generation is verified to be high with different convergence criteria. PMID:29194415

  17. A single-shot nonlinear autocorrelation approach for time-resolved physics in the vacuum ultraviolet spectral range

    International Nuclear Information System (INIS)

    Rompotis, Dimitrios

    2016-02-01

    In this work, a single-shot temporal metrology scheme operating in the vacuum-extreme ultraviolet spectral range has been designed and experimentally implemented. Utilizing an anti-collinear geometry, a second-order intensity autocorrelation measurement of a vacuum ultraviolet pulse can be performed by encoding temporal delay information on the beam propagation coordinate. An ion-imaging time-of-flight spectrometer, offering micrometer resolution has been set-up for this purpose. This instrument enables the detection of a magnified image of the spatial distribution of ions exclusively generated by direct two-photon absorption in the combined counter-propagating pulse focus and thus obtain the second-order intensity autocorrelation measurement on a single-shot basis. Additionally, an intense VUV light source based on high-harmonic generation has been experimentally realized. It delivers intense sub-20 fs Ti:Sa fifth-harmonic pulses utilizing a loose-focusing geometry in a long Ar gas cell. The VUV pulses centered at 161.8 nm reach pulse energies of 1.1 μJ per pulse, while the corresponding pulse duration is measured with a second-order, fringe-resolved autocorrelation scheme to be 18 ± 1 fs on average. Non-resonant, two-photon ionization of Kr and Xe and three-photon ionization of Ne verify the fifth-harmonic pulse intensity and indicate the feasibility of multi-photon VUV pump/VUV probe studies of ultrafast atomic and molecular dynamics. Finally, the extended functionally of the counter-propagating pulse metrology approach is demonstrated by a single-shot VUV pump/VUV probe experiment aiming at the investigation of ultrafast dissociation dynamics of O 2 excited in the Schumann-Runge continuum at 162 nm.

  18. Single shot three-dimensional pulse sequence for hyperpolarized13C MRI.

    Science.gov (United States)

    Wang, Jiazheng; Wright, Alan J; Hu, De-En; Hesketh, Richard; Brindle, Kevin M

    2017-02-01

    Metabolic imaging with hyperpolarized 13 C-labeled cell substrates is a promising technique for imaging tissue metabolism in vivo. However, the transient nature of the hyperpolarization, and its depletion following excitation, limits the imaging time and the number of excitation pulses that can be used. We describe here a single-shot three-dimensional (3D) imaging sequence and demonstrate its capability to generate 13 C MR images in tumor-bearing mice injected with hyperpolarized [1- 13 C]pyruvate. The pulse sequence acquires a stack-of-spirals at two spin echoes after a single excitation pulse and encodes the kz-dimension in an interleaved manner to enhance robustness to B 0 inhomogeneity. Spectral-spatial pulses are used to acquire dynamic 3D images from selected hyperpolarized 13 C-labeled metabolites. A nominal spatial/temporal resolution of 1.25 × 1.25 × 2.5 mm 3  × 2 s was achieved in tumor images of hyperpolarized [1- 13 C]pyruvate and [1- 13 C]lactate acquired in vivo. Higher resolution in the z-direction, with a different k-space trajectory, was demonstrated in measurements on a thermally polarized [1- 13 C]lactate phantom. The pulse sequence is capable of imaging hyperpolarized 13 C-labeled substrates at relatively high spatial and temporal resolutions and is robust to moderate system imperfections. Magn Reson Med 77:740-752, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.

  19. Do Susceptibility Weighted Imaging and Multi-Shot Echo Planar Imaging Optimally Demonstrate and Predict Outcome for Spinal Cord Injury

    Science.gov (United States)

    2017-03-27

    to manufacture, use, or sell any patented invention that may relate to them. Qualified requestors may obtain copies of this report from the...Spinal Injury Association (ASIA) impairment scale A, B, C, or D injury. Inclusion criteria were as follows: (a) age ≥ 18 years old, both genders , (b...morphology of cervical spine fracture. In addition, 15 neurologically intact healthy volunteers with comparable age and gender were recruited to

  20. Diffusion Tensor Imaging of Lumbar Nerve Roots: Comparison Between Fast Readout-Segmented and Selective-Excitation Acquisitions.

    Science.gov (United States)

    Manoliu, Andrei; Ho, Michael; Nanz, Daniel; Piccirelli, Marco; Dappa, Evelyn; Klarhöfer, Markus; Del Grande, Filippo; Kuhn, Felix Pierre

    2016-08-01

    The aim of this study was to compare the quality of recently emerged advanced diffusion tensor imaging (DTI) techniques with conventional single-shot echo-planar imaging (EPI) in a functional assessment of lumbar nerve roots. The institutional review board approved the study including 12 healthy volunteers. Diffusion tensor imaging was performed at 3 T (MAGNETOM Skyra; Siemens Healthcare) with b-values of 0 and 700 s/mm and an isotropic spatial resolution for subsequent multiplanar reformatting. The nerve roots L2 to S1 were imaged in coronal orientation with readout-segmented EPI (rs-DTI) and selective-excitation EPI (sTX-DTI) with an acquisition time of 5 minutes each, and in axial orientation with single-shot EPI (ss-DTI) with an acquisition time of 12 minutes (scan parameters as in recent literature). Two independent readers qualitatively and quantitatively assessed image quality. The interobserver reliability ranged from "substantial" to "almost perfect" for all examined parameter and all 3 sequences (κ = 0.70-0.94). Overall image quality was rated higher, and artifact levels were scored lower for rs-DTI and sTX-DTI than for ss-DTI (P = 0.007-0.027), while fractional anisotropy and signal-to-noise ratio values were similar for all sequences (P ≥ 0.306 and P ≥ 0.100, respectively). Contrast-to-noise ratios were significantly higher for rs-DTI and ss-DTI than for sTX-DTI (P = 0.004-0.013). Despite shorter acquisition times, rs-DTI and sTX-DTI produced images of higher quality with smaller geometrical distortions than the current standard of reference, ss-DTI. Thus, DTI acquisitions in the coronal plane, requiring fewer slices for full coverage of exiting nerve roots, may allow for functional neurography in scan times suitable for routine clinical practice.

  1. Diffusion tensor tractography of the brainstem pyramidal tract; A study on the optimal reduction factor in parallel imaging

    International Nuclear Information System (INIS)

    Bae, Yun Jung; Park, Jong Bin; Kim, Jae Hyoung; Choi, Byung Se; Jung, Cheol Kyu

    2016-01-01

    Parallel imaging mitigates susceptibility artifacts that can adversely affect diffusion tensor tractography (DTT) of the pons depending on the reduction (R) factor. We aimed to find the optimal R factor for DTT of the pons that would allow us to visualize the largest possible number of pyramidal tract fibers. Diffusion tensor imaging was performed on 10 healthy subjects at 3 Tesla based on single-shot echo-planar imaging using the following parameters: b value, 1000 s/mm 2 ; gradient direction, 15; voxel size, 2 × 2 × 2 mm 3 ; and R factors, 1, 2, 3, 4, and 5. DTT of the right and left pyramidal tracts in the pons was conducted in all subjects. Signal-to-noise ratio (SNR), image distortion, and the number of fibers in the tracts were compared across R factors. SNR, image distortion, and fiber number were significantly different according to R factor. Maximal SNR was achieved with an R factor of 2. Image distortion was minimal with an R factor of 5. The number of visible fibers was greatest with an R factor of 3. R factor 3 is optimal for DTT of the pontine pyramidal tract. A balanced consideration of SNR and image distortion, which do not have the same dependence on the R factor, is necessary for DTT of the pons

  2. Diffusion tensor tractography of the brainstem pyramidal tract; A study on the optimal reduction factor in parallel imaging

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Yun Jung; Park, Jong Bin; Kim, Jae Hyoung; Choi, Byung Se; Jung, Cheol Kyu [Dept. of of Radiology, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2016-08-15

    Parallel imaging mitigates susceptibility artifacts that can adversely affect diffusion tensor tractography (DTT) of the pons depending on the reduction (R) factor. We aimed to find the optimal R factor for DTT of the pons that would allow us to visualize the largest possible number of pyramidal tract fibers. Diffusion tensor imaging was performed on 10 healthy subjects at 3 Tesla based on single-shot echo-planar imaging using the following parameters: b value, 1000 s/mm{sup 2}; gradient direction, 15; voxel size, 2 × 2 × 2 mm{sup 3}; and R factors, 1, 2, 3, 4, and 5. DTT of the right and left pyramidal tracts in the pons was conducted in all subjects. Signal-to-noise ratio (SNR), image distortion, and the number of fibers in the tracts were compared across R factors. SNR, image distortion, and fiber number were significantly different according to R factor. Maximal SNR was achieved with an R factor of 2. Image distortion was minimal with an R factor of 5. The number of visible fibers was greatest with an R factor of 3. R factor 3 is optimal for DTT of the pontine pyramidal tract. A balanced consideration of SNR and image distortion, which do not have the same dependence on the R factor, is necessary for DTT of the pons.

  3. Analysis and enhancement of 3D shape accuracy in a single-shot LIDAR sensor

    Science.gov (United States)

    Han, Munhyun; Choi, Gudong; Song, Minhyup; Seo, Hongseok; Mheen, Bongki

    2017-02-01

    The accuracy of timing jitter is of prime importance in the prevalent utilization of Light Detection and Ranging (LiDAR) technology for the real-time high-resolution three-dimensional (3D) image sensor, especially for relatively small object detection in various applications, such as in the fully automated car navigation and military surveillance. To assess the accuracy of timing, that is, the accuracy of the distance or three-dimensional shape, the standard deviation method can be used in the Time-of-Flight (ToF) LiDAR technology. While most timing jitter analyses are mainly based on a fiber-network or open space at a relatively short range distance, more accurate analyses are required to extract more information about the timing jitter at in a 3D image sensor long-range free space conditions for extended LiDAR-related applications. In this paper, utilizing a Single-Shot LiDAR System (SSLs) model with a 400 MHz wideband InGaAs Avalanche Photodiode and a 1550 nm 2 nsec full width at half maximum MOPA fiber laser, we analyzed the precise timing jitter for the implemented SSLs to characterize the measurement results. Additionally, we report the enhanced results for the resolution and precision in the given SSLs using the spline interpolation method from the measured results, and multiple-shot averaging (MSA). Finally, by adapting the proposed method to an implemented high resolution 3D LiDAR prototype, called the STUD LiDAR prototype, which can be understood as one kind of SSLs because it has a single source and a single detector as in a SSLs, we observed and analyzed the 3D resolution enhancement.

  4. Wavelet Domain Radiofrequency Pulse Design Applied to Magnetic Resonance Imaging

    Science.gov (United States)

    Huettner, Andrew M.; Mickevicius, Nikolai J.; Ersoz, Ali; Koch, Kevin M.; Muftuler, L. Tugan; Nencka, Andrew S.

    2015-01-01

    A new method for designing radiofrequency (RF) pulses with numerical optimization in the wavelet domain is presented. Numerical optimization may yield solutions that might otherwise have not been discovered with analytic techniques alone. Further, processing in the wavelet domain reduces the number of unknowns through compression properties inherent in wavelet transforms, providing a more tractable optimization problem. This algorithm is demonstrated with simultaneous multi-slice (SMS) spin echo refocusing pulses because reduced peak RF power is necessary for SMS diffusion imaging with high acceleration factors. An iterative, nonlinear, constrained numerical minimization algorithm was developed to generate an optimized RF pulse waveform. Wavelet domain coefficients were modulated while iteratively running a Bloch equation simulator to generate the intermediate slice profile of the net magnetization. The algorithm minimizes the L2-norm of the slice profile with additional terms to penalize rejection band ripple and maximize the net transverse magnetization across each slice. Simulations and human brain imaging were used to demonstrate a new RF pulse design that yields an optimized slice profile and reduced peak energy deposition when applied to a multiband single-shot echo planar diffusion acquisition. This method may be used to optimize factors such as magnitude and phase spectral profiles and peak RF pulse power for multiband simultaneous multi-slice (SMS) acquisitions. Wavelet-based RF pulse optimization provides a useful design method to achieve a pulse waveform with beneficial amplitude reduction while preserving appropriate magnetization response for magnetic resonance imaging. PMID:26517262

  5. Symmetry of the fornix using diffusion tensor imaging.

    Science.gov (United States)

    Sboto-Frankenstein, Uta N; Lazar, Tiffany; Bolster, R Bruce; Thind, Sunny; Dreessen de Gervai, Patricia; Gruwel, Marco L H; Smith, Stephen D; Tomanek, Boguslaw

    2014-10-01

    To: 1) Present fornix tractography in its entirety for 20 healthy individuals to assess variability. 2) Provide individual and groupwise whole tract diffusion parameter symmetry assessments prior to clinical application. 3) Compare whole tract diffusion parameter assessments with tract-based spatial statistics (TBSS). Diffusion tensor imaging (DTI) data were acquired on a 3T Siemens magnetic resonance imaging (MRI) system using a single-shot spin echo planar imaging (EPI) sequence. Individual fornix tractography was conducted and whole tract diffusion parameter symmetries assessed. Whole tract results were compared with asymmetry contrasts conducted with voxelwise statistical analysis of diffusion parameters using TBSS. The fornix tract could be visualized in its entirety including the columns, body, crura, and fimbria. Contrary to the crus and body, there were some tractography inconsistencies of the columns and fimbria across subjects. Although whole tract diffusion parameter asymmetries were nonsignificant, fractional anisotropy (FA) values bordered on statistical significance (P = 0.052). Using TBSS, significant FA asymmetries were identified (P ≤ 0.01, corrected). The findings demonstrate consistency of fornix tractography as well as some variability in the columns and fimbria. While parametric assessment demonstrates diffusion parameter symmetry, permutation-based TBSS analysis reveals significant FA asymmetries in the crura and fimbriae. © 2013 Wiley Periodicals, Inc.

  6. Sjoegren's syndrome of the parotid gland: value of diffusion-weighted echo-planar MRI for diagnosis at an early stage based on MR sialography grading in comparison with healthy volunteers

    International Nuclear Information System (INIS)

    Regier, Marc; Ries, T.; Arndt, C.; Cramer, M.C.; Adam, G.; Habermann, C.R.; Graessner, J.; Reitmeier, F.; Jaehne, M.

    2009-01-01

    To investigate the value of diffusion-weighted echo-planar imaging (DW-EPI) for quantifying functional changes of the parotid gland in Sjoegren's disease and to evaluate whether ADC mapping allows for early diagnosis based on MR sialography grading. Using a DW-EPI sequence at 1.5T (b-factors: 0, 500 and 1000 sec/mm 2 ), the parotid glands of 52 healthy volunteers and 13 patients with histologically verified affection of Sjoegren's disease were examined. All scans were performed prior to and following gustatory stimulation with 5 ml of lemon juice. ADC maps were evaluated by placing an inordinate region-of-interest (ROI) enclosing the entire parotid gland. Sjoegren's disease was graded based on MR sialography findings using a 4-point grading-scale. Statistics included student t-test and kappa-analysis. In healthy volunteers mean ADCs of 1.14 x 10 -3 mm 2 /sec before and 1.2 x 10 -3 mm 2 /sec after stimulation were observed. Higher ADCs were determined for early-stage Sjoegren's disease, averaging 1.22 x 10 -3 mm 2 /sec before and 1.29 x 10 -3 mm 2 /sec after stimulation. Advanced disease revealed significantly lower ADCs (0.97 x 10 -3 mm 2 /sec (p = 0.002) before and 1.01 x 10 -3 mm 2 /sec (p < 0.001) after stimulation). (orig.)

  7. Comparative Study on the Efficacy of Two Regimens of Single-Shot ...

    African Journals Online (AJOL)

    ... mother by increasing self esteem and improving bonding with the baby. Objective: To assess and compare the satisfaction and efficacy of two regimens of single-shot spinal blocks for the relief of labor pain in women who present in active phase of labour. Design: A prospective randomised single-blind observational study

  8. Single-shot LIBS spectral quality for waste particles in open air

    NARCIS (Netherlands)

    Xia, H.; Bakker, M.C.M.

    2015-01-01

    This work investigates the ability of LIBS to produce quality spectra from small particles of concrete demolition waste using single-shot spectra collected in open air. The 2–8?mm materials are rounded river gravel, green glass shards, and plastic flakes. Considered are focal length, air, moisture,

  9. Single shot damage mechanism of Mo/Si multilayer optics under intense pulsed XUV-exposures

    NARCIS (Netherlands)

    Khorsand, A.R.; Sobierajski, R.; Louis, Eric; Bruijn, S.; Gleeson, A.; van de Kruijs, Robbert Wilhelmus Elisabeth; Gullikson, E.M.; Bijkerk, Frederik

    2010-01-01

    We investigated single shot damage of Mo/Si multilayer coatings exposed to the intense fs XUV radiation at the Free-electron LASer facility in Hamburg - FLASH. The interaction process was studied in situ by XUV reflectometry, time resolved optical microscopy, and “post-mortem” by

  10. Real-time single-shot electron bunch length measurements

    CERN Document Server

    Wilke, I; Gillespie, W A; Berden, G; Knippels, G M H; Meer, A F G

    2002-01-01

    Linear accelerators employed as drivers for X-ray free electron lasers (FELs) require relativistic electron bunch with sub-picosecond bunch length. Precise bunch length measurements are important for the tuning and operation of the FELs. Previously, we have demonstrated that electro-optic detection is a powerful technique for sub-picosecond electron bunch length measurements. In those experiments, the measured bunch length was the average of all electron bunches within a macropulse. Here, for the first time, we present the measurement of the length of individual electron bunches using a development of our previous technique. In this experiment, the longitudinal electron bunch shape is encoded electro-optically on to the frequency spectrum of a chirped laser pulse. Subsequently, the laser pulse is dispersed by a grating and the spectrum is imaged with a CCD camera. Single bunch measurements are achieved by using a nanosecond gated camera, and synchronizing the gate with both the electron bunch and the laser pu...

  11. Quantitative single shot and spatially resolved plasma wakefield diagnostics

    CERN Document Server

    Kasim, Muhammad Firmansyah; Ceurvorst, Luke; Levy, Matthew C; Ratan, Naren; Sadler, James; Bingham, Robert; Burrows, Philip N; Trines, Raoul; Wing, Matthew; Norreys, Peter

    2015-01-01

    Diagnosing plasma conditions can give great advantages in optimizing plasma wakefield accelerator experiments. One possible method is that of photon acceleration. By propagating a laser probe pulse through a plasma wakefield and extracting the imposed frequency modulation, one can obtain an image of the density modulation of the wakefield. In order to diagnose the wakefield parameters at a chosen point in the plasma, the probe pulse crosses the plasma at oblique angles relative to the wakefield. In this paper, mathematical expressions relating the frequency modulation of the laser pulse and the wakefield density profile of the plasma for oblique crossing angles are derived. Multidimensional particle-in-cell simulation results presented in this paper confirm that the frequency modulation profiles and the density modulation profiles agree to within 10%. Limitations to the accuracy of the measurement are discussed in this paper. This technique opens new possibilities to quantitatively diagnose the plasma wakefie...

  12. Magnetic resonance diffusion tensor imaging and tractography of intracranial cavernous malformations: preliminary observations and characterization of the hemosiderin rim.

    Science.gov (United States)

    Cauley, Keith A; Andrews, Trevor; Gonyea, Jay V; Filippi, Christopher G

    2010-04-01

    Cavernous malformations (CMs) can cause symptoms that appear out of proportion to the lesion size, leading one to hypothesize that they may have an effect on adjacent white matter that is not fully explained by local mass effect. The goal of this study was to investigate the diffusion tensor (DT) properties of CMs, the hemosiderin rim, and normal-appearing adjacent white matter. Eighteen cavernous malformations were characterized using standard MR imaging sequences as well as 6-direction DT imaging with single-shot echo planar-gradient echo imaging at 3 tesla. Diffusion tensor imaging demonstrated that CMs have a characteristic signature on DT imaging, with low fractional anisotropy (FA) and high mean diffusivity centrally within the lesion. The hemosiderin rim had a high FA value relative to the central lesion or adjacent white matter. Tractography revealed that tracts neatly deviate around CMs. Tracts were typically seen to pass through the hemosiderin rim. The hemosiderin rim of CMs was intimately associated with white matter tracts that were deviated by the central lesion. These findings are consistent with histopathological reports that the hemosiderin rim is composed of blood breakdown products deposited in viable white matter.

  13. Multi-slice echo-planar spectroscopic MR imaging provides both global and local metabolite measures in multiple sclerosis

    DEFF Research Database (Denmark)

    Mathiesen, Henrik Kahr; Tscherning, Thomas; Sorensen, Per Soelberg

    2005-01-01

    MR spectroscopy (MRS) provides information about neuronal loss or dysfunction by measuring decreases in N-acetyl aspartate (NAA), a metabolite widely believed to be a marker of neuronal viability. In multiple sclerosis (MS), whole-brain NAA (WBNAA) has been suggested as a marker of disease...

  14. A characteristic feature of acute haematomas in the brain on echo-planar diffusion-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Morita, N.; Yoneda, K.; Nishitani, H. [Department of Radiology, School of Medicine, University of Tokushima, 3-18-15, Kuramoto-Cho, Tokushima 770-8503 (Japan); Harada, M. [Department of Radiologic Technology, School of Health Sciences, University of Tokushima, 3-18-15, Kuramoto-Cho, Tokushima 770-8509 (Japan); Uno, M. [Department of Neurosurgery, School of Medicine, University of Tokushima, 3-18-15, Kuramoto-Cho, Tokushima 770-8503 (Japan)

    2002-11-01

    Diffusion-weighted MRI (DWI) is used in the diagnosis of acute ischaemic disease of the brain, but it is not clear whether or not it can be used to differentiate an acute haematoma from an infarct. Our purpose was to identify any characteristic feature of acute haematomas which can be recognised on DWI and to evaluate the usefulness of DWI in acute cerebral stroke. We examined nine patients with acute haemorrhage using CT and MRI including DWI. We measured the volume and apparent diffusion coefficient (ADC) of the haematomas. All showed heterogeneous signal on DWI, and the centre of the large (>20 ml) haematomas especially a mixed pattern with high and low signal. The characteristic feature of acute haematomas was a peripheral low-signal region, found in all subjects regardless of the size of the haematoma; acute infarcts did not show this. This low-signal rim on DWI may be useful for differentiating an acute haematoma from an infarct. (orig.)

  15. Functional magnetic resonance imaging using non-Fourier, spatially selective radiofrequency encoding.

    Science.gov (United States)

    Yoo, S S; Guttmann, C R; Panych, L P

    1999-04-01

    A new method for functional magnetic resonance imaging (fMRI) employing non-Fourier encoding using spatially selective radiofrequency (RF) excitation is presented. The method uses manipulation of spatially selective RF pulses to encode spins in the slice-select direction. The method has several advantages over standard multislice approaches. It provides a simple means for monitoring irregularly distributed sections throughout a volume without the need to encode the whole volume. It offers the potential for increased signal-to-noise ratio if an appropriate basis is used for encoding. With a unique design of excitation pulses, it also appears possible to significantly reduce in-flow effects. An interleaved echo-planar imaging (EPI) sequence was adapted for non-Fourier encoding in the slice-select direction and was implemented on a conventional 1.5-Telsa system. The method was then used for functional mapping of the visual and motor areas where significant reduction of in-flow effect was demonstrated. This approach can be adapted to other imaging sequences that are used for fMRI, such as single-shot EPI.

  16. In vivo diffusion-weighted imaging of liver tumor necrosis in the VX2 rabbit model at 1.5 Tesla.

    Science.gov (United States)

    Deng, Jie; Rhee, Thomas K; Sato, Kent T; Salem, Riad; Haines, Kenneth; Paunesku, Tatjana; Mulcahy, Mary F; Miller, Frank H; Omary, Reed A; Larson, Andrew C

    2006-04-01

    We sought to demonstrate the feasibility of using single-shot spin-echo echo-planar imaging for imaging liver tumor necrosis in the in vivo VX2 rabbit model at 1.5 T. VX2 liver tumors were grown in 4 rabbits. Diffusion-weighted images (DWIs) were acquired during breath-hold using twice refocused SE-EPI (b = 0, 700, 1400 seconds/mm). Anatomic images for tumor size measurements were acquired using T2W TSE. Rabbits were euthanized for subsequent necropsy. Viable and necrotic tumor tissue ADC measurements were performed with reference to hematoxylin and eosin pathology. A total of 8 tumors were grown with diameters ranging from 1.2 to 5.3 cm. Viable and necrotic tumor compartments were clearly differentiated. Apparent diffusion coefficient in necrotic tumor cores, 1.26 +/- 0.11 x 10 mm/s, were significantly greater than those in surrounding viable tumor tissues, 0.74 +/- 0.06 x 10 mm/s (mean +/- SD, P model is feasible using a 1.5 T clinical magnetic resonance imaging scanner. DWI may permit longitudinal assessment of liver tumor therapies in both preclinical and clinical studies.

  17. Speckle noise reduction in single-shot holographic two-wavelength contouring

    Science.gov (United States)

    Agour, Mostafa; Klattenhoff, Reiner; Falldorf, Claas; Bergmann, Ralf B.

    2017-05-01

    We present an experimental configuration that enables form measurement from a single-shot camera exposure. It combines two-wavelength contouring with spatial multiplexing synthetic-aperture digital holography. The synthetic-aperture in this work is formed by simultaneously illuminating the test object from two different angles. The two illumination directions and the two-wavelength contouring result in four holograms which are spatially multiplexed on a single camera target avoiding unwanted cross-interference between them by means of coherence gating. In contrast to standard holographic contouring methods, the proposed technique reduces speckle decorrelation noise and enables single shot form measurement. To demonstrate this technique, the shape of a micro cold drawing part is determined.

  18. Single-shot observation of growing streamers using an ultrafast camera

    International Nuclear Information System (INIS)

    Takahashi, E; Kato, S; Furutani, H; Sasaki, A; Kishimoto, Y; Takada, K; Matsumura, S; Sasaki, H

    2011-01-01

    A recently developed ultrafast camera that can acquire 10 8 frames per second was used to investigate positive streamer discharge. It enabled single-shot evaluation of streamer evolution without the need to consider shot-to-shot reproducibility. This camera was used to investigate streamers in argon. Growing branches, the transition when a streamer forms a return stroke, and related phenomena were clearly observed. (fast track communication)

  19. Infrared single shot diagnostics for the longitudinal profile of the electron bunches at FLASH

    International Nuclear Information System (INIS)

    Delsim-Hashemi, Hossein

    2008-09-01

    The longitudinal profile of electron bunches plays an important role in the design of single-pass free electron lasers and future linear e + e - colliders. For the free electron laser FLASH in Hamburg, a longitudinal compression scheme is used which results in an asymmetric longitudinal bunch profile with a 'spike'. This 'spike', which has a very high peak current, is used in a high-gain SASE-FEL process to produce high intensity (about 70 μJ) femtosecond photon pulses in the XUV wavelength range. The required high peak current of the electron bunch is realized by confining a large number of electrons in a width, measured in time units, of few tens of femtosecond, making the diagnostics of such bunches a challenge. Furthermore, the operation of facilities such as FLASH shows that single-shot diagnostics is indispensable. It is intuitive to use a time domain method to measure the electron bunch length. However, when the structures present in the bunch profile fall in the femtoseconds range, this is beyond the resolution of time-resolved methods developed so far. In this thesis, a wavelength-domain technique is described that can fulfill both requirements of single shot and high resolution reaching to the femtoseconds range. The amount of charge that is confined in a typical length of several femtoseconds (FWHM of the spike) can be determined by a novel single-shot spectrometer that resolves the coherent radiation (e.g. coherent transition radiation) in the far-infrared and mid-infrared range. Furthermore the extension of this single-shot spectroscopy to shorter wavelengths reaching the near-infrared, makes it possible to investigate the presence of structures in the bunch profile that might correlate or anti-correlate to the SASE intensity. (orig.)

  20. Infrared single shot diagnostics for the longitudinal profile of the electron bunches at FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Delsim-Hashemi, Hossein

    2008-09-15

    The longitudinal profile of electron bunches plays an important role in the design of single-pass free electron lasers and future linear e{sup +}e{sup -} colliders. For the free electron laser FLASH in Hamburg, a longitudinal compression scheme is used which results in an asymmetric longitudinal bunch profile with a 'spike'. This 'spike', which has a very high peak current, is used in a high-gain SASE-FEL process to produce high intensity (about 70 {mu}J) femtosecond photon pulses in the XUV wavelength range. The required high peak current of the electron bunch is realized by confining a large number of electrons in a width, measured in time units, of few tens of femtosecond, making the diagnostics of such bunches a challenge. Furthermore, the operation of facilities such as FLASH shows that single-shot diagnostics is indispensable. It is intuitive to use a time domain method to measure the electron bunch length. However, when the structures present in the bunch profile fall in the femtoseconds range, this is beyond the resolution of time-resolved methods developed so far. In this thesis, a wavelength-domain technique is described that can fulfill both requirements of single shot and high resolution reaching to the femtoseconds range. The amount of charge that is confined in a typical length of several femtoseconds (FWHM of the spike) can be determined by a novel single-shot spectrometer that resolves the coherent radiation (e.g. coherent transition radiation) in the far-infrared and mid-infrared range. Furthermore the extension of this single-shot spectroscopy to shorter wavelengths reaching the near-infrared, makes it possible to investigate the presence of structures in the bunch profile that might correlate or anti-correlate to the SASE intensity. (orig.)

  1. Single-Shot Readout of a Superconducting Qubit using a Josephson Parametric Oscillator

    Science.gov (United States)

    2016-01-11

    Single-shot Readout of a Superconducting Qubit using a Josephson Parametric Oscillator Philip Kranz1, Andreas Bengtsson1, Michaël Simoen1, Simon...Josephson Parametric Oscillator Philip Krantz1, Andreas Bengtsson1, Michaël Simoen1, Simon Gustavsson2, Vitaly Shumeiko1, W. D. Oliver2,3, C. M...2016) We propose and demonstrate a new read-out technique for a superconducting qubit by dispersively coupling it to a Josephson parametric

  2. Reliability Assessment of a Single-Shot System by Use of Screen Test Results

    Science.gov (United States)

    2018-02-01

    unlimited. NUWC Keyport #17-002. Reliability Assessment of a Single-Shot System by Use of Screen Test Results Abstract: Field reliability prediction...approach described here assumes that the defect density during testing takes the form of an exponential decay, although other mathematical functions can...be substituted for the exponential. In order to apply the decay rate function to a discrete pass/fail test scheme, the approach provides for

  3. Sjoegren's syndrome of the parotid gland: value of diffusion-weighted echo-planar MRI for diagnosis at an early stage based on MR sialography grading in comparison with healthy volunteers

    Energy Technology Data Exchange (ETDEWEB)

    Regier, Marc; Ries, T.; Arndt, C.; Cramer, M.C.; Adam, G.; Habermann, C.R. [Universitaetsklinikum Hamburg-Eppendorf (Germany). Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie; Graessner, J. [Siemens AG, Hamburg (Germany). Medical Solutions; Reitmeier, F.; Jaehne, M. [Universitaetsklinikum Hamburg-Eppendorf (Germany). Klinik und Poliklinik fuer Hals-, Nasen- und Ohrenheilkunde

    2009-03-15

    To investigate the value of diffusion-weighted echo-planar imaging (DW-EPI) for quantifying functional changes of the parotid gland in Sjoegren's disease and to evaluate whether ADC mapping allows for early diagnosis based on MR sialography grading. Using a DW-EPI sequence at 1.5T (b-factors: 0, 500 and 1000 sec/mm{sup 2}), the parotid glands of 52 healthy volunteers and 13 patients with histologically verified affection of Sjoegren's disease were examined. All scans were performed prior to and following gustatory stimulation with 5 ml of lemon juice. ADC maps were evaluated by placing an inordinate region-of-interest (ROI) enclosing the entire parotid gland. Sjoegren's disease was graded based on MR sialography findings using a 4-point grading-scale. Statistics included student t-test and kappa-analysis. In healthy volunteers mean ADCs of 1.14 x 10{sup -3} mm{sup 2} /sec before and 1.2 x 10{sup -3} mm{sup 2} /sec after stimulation were observed. Higher ADCs were determined for early-stage Sjoegren's disease, averaging 1.22 x 10{sup -3} mm{sup 2} /sec before and 1.29 x 10{sup -3} mm{sup 2} /sec after stimulation. Advanced disease revealed significantly lower ADCs (0.97 x 10{sup -3} mm{sup 2} /sec (p = 0.002) before and 1.01 x 10{sup -3} mm{sup 2} /sec (p < 0.001) after stimulation). (orig.)

  4. Anti-botulism single-shot vaccine using chitosan for protein encapsulation by simple coacervation.

    Science.gov (United States)

    Sari, Roger S; de Almeida, Anna Christina; Cangussu, Alex S R; Jorge, Edson V; Mozzer, Otto D; Santos, Hércules Otacílio; Quintilio, Wagner; Brandi, Igor Viana; Andrade, Viviane Aguiar; Miguel, Angelo Samir M; Sobrinho Santos, Eliane M

    2016-12-01

    The aim of the present study was to compare the potency and safety of vaccines against Clostridium botulinum (C. botulinum) type C and D formulated with chitosan as controlled release matrix and vaccines formulated in conventional manner using aluminum hydroxide. Parameters were established for the development of chitosan microspheres, using simple coacervation to standardize the use of this polymer in protein encapsulation for vaccine formulation. To formulate a single shot vaccine inactivated antigens of C. botulinum type C and D were used with original toxin titles equal to 5.2 and 6.2 log LD50/ml, respectively. For each antigen a chitosan based solution of 50 mL was prepared. Control vaccines were formulated by mixing toxoid type C and D with aluminum hydroxide [25% Al(OH) 3 , pH 6.3]. The toxoid sterility, innocuity and potency of vaccines were evaluated as stipulated by MAPA-BRASIL according to ministerial directive no. 23. Encapsulation efficiency of BSA in chitosan was 32.5-40.37%, while that the encapsulation efficiency to toxoid type C was 41,03% (1.94 mg/mL) and of the toxoid type D was 32.30% (1.82 mg/mL). The single shot vaccine formulated using chitosan for protein encapsulation through simple coacervation showed potency and safety similar to conventional vaccine currently used in Brazilian livestock (10 and 2 IU/mL against C. botulinum type C and D, respectively). The present work suggests that our single shot vaccine would be a good option as a cattle vaccine against these C. botulinum type C and D. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Single-shot secure quantum network coding on butterfly network with free public communication

    Science.gov (United States)

    Owari, Masaki; Kato, Go; Hayashi, Masahito

    2018-01-01

    Quantum network coding on the butterfly network has been studied as a typical example of quantum multiple cast network. We propose a secure quantum network code for the butterfly network with free public classical communication in the multiple unicast setting under restricted eavesdropper’s power. This protocol certainly transmits quantum states when there is no attack. We also show the secrecy with shared randomness as additional resource when the eavesdropper wiretaps one of the channels in the butterfly network and also derives the information sending through public classical communication. Our protocol does not require verification process, which ensures single-shot security.

  6. Contrast-enhanced CT and diffusion-weighted MR imaging: Performance as a prognostic factor in patients with pancreatic ductal adenocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Fukukura, Yoshihiko, E-mail: fukukura@m.kufm.kagoshima-u.ac.jp [Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan); Takumi, Koji [Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan); Higashi, Michiyo [Department of Human Pathology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan); Shinchi, Hiroyuki [Department of Surgical Oncology and Digestive Surgery, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan); Kamimura, Kiyohisa; Yoneyama, Tomohide; Tateyama, Akihiro [Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan)

    2014-04-15

    Objective: To determine whether contrast enhancement of CT and apparent diffusion coefficient on diffusion-weighted MR imaging are important parameters that can predict outcomes for patients with pancreatic ductal adenocarcinoma. Materials and methods: Ninety-two patients with histologically confirmed pancreatic ductal adenocarcinoma who underwent quadriphasic CT (including unenhanced, pancreatic parenchymal, portal venous and delayed phases) and fat-suppressed single-shot echo-planar diffusion-weighted MR imaging at 3.0 T were retrospectively analyzed to investigate prognostic factors. Overall survival curves were drawn using the Kaplan–Meier method. Effects on survival of variables including age, sex, tumor location, tumor size, TNM stage, carbohydrate antigen 19-9, carcinoembryonic antigen, treatment, tumor contrast enhancement and apparent diffusion coefficient values were analyzed in univariate analysis using the log-rank test. Variables were analyzed in multivariate analyses using the Cox proportional hazards regression model. Results: Median survival for the entire patient population was 18.2 months. Higher contrast enhancement during all phases was associated with significantly longer overall survival (P < 0.001 for all phases). The difference in overall survival between groups divided by median apparent diffusion coefficient value was not significant (P = 0.672). TNM stage (P = 0.026) and tumor contrast enhancement on CT (P = 0.027) were significantly related to survival in multivariate analysis. Conclusions: Poor enhancement of pancreatic adenocarcinomas on enhanced CT is associated with reduced patient survival.

  7. Diffusion tensor imaging in spinal cord compression

    International Nuclear Information System (INIS)

    Wang, Wei; Qin, Wen; Hao, Nanxin; Wang, Yibin; Zong, Genlin

    2012-01-01

    Background Although diffusion tensor imaging has been successfully applied in brain research for decades, several main difficulties have hindered its extended utilization in spinal cord imaging. Purpose To assess the feasibility and clinical value of diffusion tensor imaging and tractography for evaluating chronic spinal cord compression. Material and Methods Single-shot spin-echo echo-planar DT sequences were scanned in 42 spinal cord compression patients and 49 healthy volunteers. The mean values of the apparent diffusion coefficient and fractional anisotropy were measured in region of interest at the cervical and lower thoracic spinal cord. The patients were divided into two groups according to the high signal on T2WI (the SCC-HI group and the SCC-nHI group for with or without high signal). A one-way ANOVA was used. Diffusion tensor tractography was used to visualize the morphological features of normal and impaired white matter. Results There were no statistically significant differences in the apparent diffusion coefficient and fractional anisotropy values between the different spinal cord segments of the normal subjects. All of the patients in the SCC-HI group had increased apparent diffusion coefficient values and decreased fractional anisotropy values at the lesion level compared to the normal controls. However, there were no statistically significant diffusion index differences between the SCC-nHI group and the normal controls. In the diffusion tensor imaging maps, the normal spinal cord sections were depicted as fiber tracts that were color-encoded to a cephalocaudal orientation. The diffusion tensor images were compressed to different degrees in all of the patients. Conclusion Diffusion tensor imaging and tractography are promising methods for visualizing spinal cord tracts and can provide additional information in clinical studies in spinal cord compression

  8. MR neurography of the median nerve at 3.0 T: Optimization of diffusion tensor imaging and fiber tractography

    International Nuclear Information System (INIS)

    Guggenberger, Roman; Eppenberger, Patrick; Markovic, Daniel; Nanz, Daniel; Chhabra, Avneesh; Pruessmann, Klaas P.; Andreisek, Gustav

    2012-01-01

    Objectives: The purpose of this study was to systematically assess the optimal b-value and reconstruction parameters for DTI and fiber tractography of the median nerve at 3.0 T. Methods: Local ethical board approved study with 45 healthy volunteers (15 men, 30 women; mean age, 41 ± 3.4 years) who underwent DTI of the right wrist at 3.0 T. A single-shot echo-planar-imaging sequence (TR/TE 10123/40 ms) was acquired at four different b-values (800, 1000, 1200, and 1400 s/mm 2 ). Two independent readers performed post processing and fiber-tractography. Fractional anisotropy (FA) maps were calculated. Fiber tracts of the median nerve were generated using four different algorithms containing different FA thresholds and different angulation tolerances. Data were evaluated quantitatively and qualitatively. Results: Tracking algorithms using a minimum FA threshold of 0.2 and a maximum angulation of 10° were significantly better than other algorithms. Fiber tractography generated significantly longer fibers in DTI acquisitions with higher b-values (1200 and 1400 s/mm 2 versus 800 s/mm 2 ; p 2 (p 2 for DTI of the median nerve at 3.0 T. Optimal reconstruction parameters for fiber tractography should encompass a minimum FA threshold of 0.2 and a maximum angulation tolerance of 10.

  9. Selective visualization of pelvic splanchnic nerve and pelvic plexus using readout-segmented echo-planar diffusion-weighted magnetic resonance neurography: A preliminary study in healthy male volunteers

    Energy Technology Data Exchange (ETDEWEB)

    Yamashita, Rikiya, E-mail: rickdom@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Isoda, Hiroyoshi, E-mail: sayuki@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Arizono, Shigeki, E-mail: arizono@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Furuta, Akihiro, E-mail: akihirof@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Ohno, Tsuyoshi, E-mail: goohno@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging, Osaka Red Cross Hospital, 5-30 Fudegasaki-cho, Tennoji-ku, Osaka, 543-8555 (Japan); Ono, Ayako, E-mail: onoayako@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Murata, Katsutoshi, E-mail: katsutoshi.murata@siemens.com [Siemens Healthcare Japan KK, Gate City Osaki West Tower, 11-1 Osaki 1-Chome, Shinagawa-ku, Tokyo 141-8644 (Japan); Togashi, Kaori, E-mail: ktogashi@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan)

    2017-01-15

    Highlights: • RS-EPI DW-MRN has a potential to selectively depict the pelvic parasympathetic nerve. • The nervous visibility showed a moderate correlation with the image artifact level. • Our method could help preserving function after pelvic nerve-preserving surgery. - Abstract: Purpose: To evaluate the potential of readout-segmented echo-planar diffusion-weighted magnetic resonance neurography (RS-EPI DW-MRN) for the selective visualization of pelvic splanchnic nerve and pelvic plexus in healthy male volunteers. Materials and methods: Institutional review board approval and written informed consent were obtained. RS-EPI DW-MRN images were acquired from thirteen healthy male volunteers aged 25–48 years between September 2013 and December 2013. For RS-EPI DW-MRN, the following parameters were used: spatial resolution, 1.1 × 1.1 × 2.5 mm; b-value, 250 s/mm{sup 2}; number of readout-segments, seven; and acquisition time, 7 min 45 s. For qualitative assessment, two abdominal radiologists independently evaluated the visibility of the pelvic splanchnic nerves and pelvic plexuses bilaterally in each subject on oblique coronal thin-slab 10-mm-thick maximum intensity projection images and scored it with a 4-point grading scale (excellent, good, fair, poor). Both readers scored twice at 6-month intervals. Inter-observer and intra-observer variability were evaluated using Cohen’s quadratically weighted κ statistics. Image artifact level was scored on a 4-point grading scale by other two abdominal radiologists in order to evaluate the correlation between the nerve visibility and the severity of imaging artifacts using the Spearman’s correlation coefficient. Results: Qualitative grading showed the following success rate (number of nerves qualitatively scored as excellent or good divided by total number of nerves): reader 1 (first set), 73% (19/26); reader 2 (first set), 77% (20/26); reader 1 (second set), 81% (21/26); and reader 2 (second set), 77% (20

  10. Anti-spoof touchless 3D fingerprint recognition system using single shot fringe projection and biospeckle analysis

    Science.gov (United States)

    Chatterjee, Amit; Bhatia, Vimal; Prakash, Shashi

    2017-08-01

    Fingerprint is a unique, un-alterable and easily collected biometric of a human being. Although it is a 3D biological characteristic, traditional methods are designed to provide only a 2D image. This touch based mapping of 3D shape to 2D image losses information and leads to nonlinear distortions. Moreover, as only topographic details are captured, conventional systems are potentially vulnerable to spoofing materials (e.g. artificial fingers, dead fingers, false prints, etc.). In this work, we demonstrate an anti-spoof touchless 3D fingerprint detection system using a combination of single shot fringe projection and biospeckle analysis. For fingerprint detection using fringe projection, light from a low power LED source illuminates a finger through a sinusoidal grating. The fringe pattern modulated because of features on the fingertip is captured using a CCD camera. Fourier transform method based frequency filtering is used for the reconstruction of 3D fingerprint from the captured fringe pattern. In the next step, for spoof detection using biospeckle analysis a visuo-numeric algorithm based on modified structural function and non-normalized histogram is proposed. High activity biospeckle patterns are generated because of interaction of collimated laser light with internal fluid flow of the real finger sample. This activity reduces abruptly in case of layered fake prints, and is almost absent in dead or fake fingers. Furthermore, the proposed setup is fast, low-cost, involves non-mechanical scanning and is highly stable.

  11. Magnetic resonance urography in pediatrics: utilization of ultrafast single-shot spin echo sequences; Urografia por resonancia magnetic en pediatria: utilizacion de las secuencias ultrarrapidas single shot en eco del espin

    Energy Technology Data Exchange (ETDEWEB)

    Martin, C.; Martin, J.; Duran, C. [Unidad de Diagnostico por la Imagen de Alta Tecnologia (UDIAT). Sabadell (Spain); Rigol, S.; Rojo, J. C. [Corporacion Sanatiaria Parc Tauli. Sabadell (Spain)

    1999-07-01

    To determine the value of magnetic resonance urography (MRU) using ultrafast single-shot (SS) rapid acquisition with relaxation enhancement (RARE) and half-Fourier (HF) SS-RARE (SS-HF-RARE or HASTE) in the evaluation of congenital urinary tract anomalies in pediatric patients, and their possible application as alternatives to intravenous urography (IVU). Eighteen children (11 boys and 7 girls) aged 2 months to 15 years (mean: 5 years) with a total of 19 congenital urinary tract anomalies were studies by MU using SS-RARE and HASTE sequences in a 1 Tesla scanner. All the patients had previously been studies by ultrasound (US) and IVU. Twelve patients required anesthesia. The images were acquired by means of a HASTE sequence with multisection technique (TR, infinite; TE{sub e}f, 87 msec; echo train, 128; interval between echoes, 10.9 msec; total acquisition time, 13 sections/12 seconds), and SS-RARE (TR, infinite; TE{sub e}f, 1.100 msec; echo train, 240, and acquisition time, 7 seconds). Four radiologists evaluated the images independently; two who reviewed the IV images in consensus and two who reviewed the MRU images in consensus. The images were evaluated to assess the dilatation of the urinary tract and their utility in detecting the level and cause of the obstruction. MRU images revealed the urinary tract dilation, the level of the obstruction and the type of anomaly in 18 patients (100%), while IVU provided this information in only 10 [ sensitivity, 53%, 95% confidence interval (29%, 76%)]. The mean time required for MRU was 20 minutes (range: 7 to 30 minutes), while that of IVU was 1,242 minutes (range: 45 to 1,440 minutes). MRU using ultrafast single-short spin echo sequences is a rapid and effective technique that permits and excellent evaluation of congenital urinary tract anomalies in pediatric patients and does not require the administration of contrast media or ionizing radiation. (Author) 10 refs.

  12. Comparison of generalized autocalibrating partially parallel acquisitions and modified sensitivity encoding for diffusion tensor imaging.

    Science.gov (United States)

    Bhagat, Y A; Emery, D J; Naik, S; Yeo, T; Beaulieu, C

    2007-02-01

    Diffusion tensor magnetic resonance imaging (DTI) of the brain is usually acquired with single-shot echo-planar imaging, which is associated with localized signal loss, geometric distortions, and blurring. Parallel imaging can lessen these artifacts by shortening the length of the echo-train acquisition. The self-calibrating parallel acquisition techniques, image domain-based modified sensitivity encoding (mSENSE) and k-space-based generalized autocalibrating partially parallel acquisitions (GRAPPA), were evaluated with DTI of the brain in 5 healthy subjects. GRAPPA and mSENSE with higher acceleration factors (R) up to 4 were compared with conventional DTI (with and without phase partial Fourier, another method of reducing the echo-train length) on a 1.5T Sonata scanner (Siemens, Erlangen, Germany). The resulting images and diffusion maps were evaluated qualitatively and quantitatively. Qualitative analysis was performed by 3 reviewers blinded to the technique using image sharpness and the level of artifacts as characteristics for scoring each set of images. Quantitative comparisons encompassed measuring signal-to-noise ratio, Trace/3 apparent diffusion coefficient (ADC), and fractional anisotropy (FA) in 6 white-matter (WM) and gray-matter (GM) regions. Reviewers scored the GRAPPA and mSENSE R = 2 images better than images acquired with conventional techniques. FA contrast was improved at the GM/WM junction in peripheral brain areas. Trace/3 ADC and FA measurements were consistent for all methods. However, R = 3,4 images suffered from reconstruction-related artifacts. GRAPPA and mSENSE (R = 2) minimized the susceptibility and off-resonance effects associated with conventional DTI methods, yielding high-quality images and reproducible quantitative diffusion measurements.

  13. Comparison of qualitative and quantitative evaluation of diffusion-weighted MRI and chemical-shift imaging in the differentiation of benign and malignant vertebral body fractures.

    Science.gov (United States)

    Geith, Tobias; Schmidt, Gerwin; Biffar, Andreas; Dietrich, Olaf; Dürr, Hans Roland; Reiser, Maximilian; Baur-Melnyk, Andrea

    2012-11-01

    The objective of our study was to compare the diagnostic value of qualitative diffusion-weighted imaging (DWI), quantitative DWI, and chemical-shift imaging in a single prospective cohort of patients with acute osteoporotic and malignant vertebral fractures. The study group was composed of patients with 26 osteoporotic vertebral fractures (18 women, eight men; mean age, 69 years; age range, 31 years 6 months to 86 years 2 months) and 20 malignant vertebral fractures (nine women, 11 men; mean age, 63.4 years; age range, 24 years 8 months to 86 years 4 months). T1-weighted, STIR, and T2-weighted sequences were acquired at 1.5 T. A DW reverse fast imaging with steady-state free precession (PSIF) sequence at different delta values was evaluated qualitatively. A DW echo-planar imaging (EPI) sequence and a DW single-shot turbo spin-echo (TSE) sequence at different b values were evaluated qualitatively and quantitatively using the apparent diffusion coefficient. Opposed-phase sequences were used to assess signal intensity qualitatively. The signal loss between in- and opposed-phase images was determined quantitatively. Two-tailed Fisher exact test, Mann-Whitney test, and receiver operating characteristic analysis were performed. Sensitivities, specificities, and accuracies were determined. Qualitative DW-PSIF imaging (delta = 3 ms) showed the best performance for distinguishing between benign and malignant fractures (sensitivity, 100%; specificity, 88.5%; accuracy, 93.5%). Qualitative DW-EPI (b = 50 s/mm(2) [p = 1.00]; b = 250 s/mm(2) [p = 0.50]) and DW single-shot TSE imaging (b = 100 s/mm(2) [p = 1.00]; b = 250 s/mm(2) [p = 0.18]; b = 400 s/mm(2) [p = 0.18]; b = 600 s/mm(2) [p = 0.39]) did not indicate significant differences between benign and malignant fractures. DW-EPI using a b value of 500 s/mm(2) (p = 0.01) indicated significant differences between benign and malignant vertebral fractures. Quantitative DW-EPI (p = 0.09) and qualitative opposed-phase imaging (p = 0

  14. Optimization And Single-Shot Characterization Of Ultrashort Thz Pulses From A Laser Wakefield Accelerator

    International Nuclear Information System (INIS)

    Plateau, G.R.; Matlis, N.H.; van Tilborg, J.; Geddes, C.G.R.; Toth, Cs.; Schroeder, C.B.; Leemans, W.P.

    2009-01-01

    We present spatiotemporal characterization of μJ-class ultrashort THz pulses generated from a laser wakefield accelerator (LWFA). Accelerated electrons, resulting from the interaction of a high-intensity laser pulse with a plasma, emit high-intensity THz pulses as coherent transition radiation. Such high peak-power THz pulses, suitable for high-field (MV/cm) pump-probe experiments, also provide a non-invasive bunch-length diagnostic and thus feedback for the accelerator. The characterization of the THz pulses includes energy measurement using a Golay cell, 2D sign-resolved electro-optic measurement and single-shot spatiotemporal electric-field distribution retrieval using a new technique, coined temporal electric-field cross-Correlation (TEX). All three techniques corroborate THz pulses of ∼ 5 μJ, with peak fields of 100's of kV/cm and ∼ 0.4 ps rms duration.

  15. Single-Shot Quantum Nondemolition Detection of Individual Itinerant Microwave Photons

    Science.gov (United States)

    Besse, Jean-Claude; Gasparinetti, Simone; Collodo, Michele C.; Walter, Theo; Kurpiers, Philipp; Pechal, Marek; Eichler, Christopher; Wallraff, Andreas

    2018-04-01

    Single-photon detection is an essential component in many experiments in quantum optics, but it remains challenging in the microwave domain. We realize a quantum nondemolition detector for propagating microwave photons and characterize its performance using a single-photon source. To this aim, we implement a cavity-assisted conditional phase gate between the incoming photon and a superconducting artificial atom. By reading out the state of this atom in a single shot, we reach an external (internal) photon-detection fidelity of 50% (71%), limited by transmission efficiency between the source and the detector (75%) and the coherence properties of the qubit. By characterizing the coherence and average number of photons in the field reflected off the detector, we demonstrate its quantum nondemolition nature. We envisage applications in generating heralded remote entanglement between qubits and for realizing logic gates between propagating microwave photons.

  16. Single-shot read-out of a superconducting qubit using a Josephson parametric oscillator

    Science.gov (United States)

    Krantz, Philip; Bengtsson, Andreas; Simoen, Michaël; Gustavsson, Simon; Shumeiko, Vitaly; Oliver, W. D.; Wilson, C. M.; Delsing, Per; Bylander, Jonas

    2016-01-01

    We propose and demonstrate a read-out technique for a superconducting qubit by dispersively coupling it with a Josephson parametric oscillator. We employ a tunable quarter wavelength superconducting resonator and modulate its resonant frequency at twice its value with an amplitude surpassing the threshold for parametric instability. We map the qubit states onto two distinct states of classical parametric oscillation: one oscillating state, with 185±15 photons in the resonator, and one with zero oscillation amplitude. This high contrast obviates a following quantum-limited amplifier. We demonstrate proof-of-principle, single-shot read-out performance, and present an error budget indicating that this method can surpass the fidelity threshold required for quantum computing. PMID:27156732

  17. Single shot near edge x-ray absorption fine structure spectroscopy in the laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Mantouvalou, I., E-mail: ioanna.mantouvalou@tu-berlin.de; Witte, K.; Martyanov, W.; Jonas, A.; Grötzsch, D.; Kanngießer, B. [Institute for Optics and Atomic Physics, Technical University of Berlin, D-10623 Berlin (Germany); Streeck, C. [Physikalisch-Technische Bundesanstalt (PTB), D-10587 Berlin (Germany); Löchel, H.; Rudolph, I.; Erko, A. [Helmholtz-Zentrum Berlin, D-14109 Berlin (Germany); Stiel, H. [Max Born Institute for Nonlinear Optics and Short Pulse Spectroscopy, D-12489 Berlin (Germany)

    2016-05-16

    With the help of adapted off-axis reflection zone plates, near edge X-ray absorption fine structure spectra at the C and N K-absorption edge have been recorded using a single 1.2 ns long soft X-ray pulse. The transmission experiments were performed with a laser-produced plasma source in the laboratory rendering time resolved measurements feasible independent on large scale facilities. A resolving power of E/ΔE ∼ 950 at the respective edges could be demonstrated. A comparison of single shot spectra with those collected with longer measuring time proves that all features of the used reference samples (silicon nitrate and polyimide) can be resolved in 1.2 ns. Hence, investigations of radiation sensitive biological specimen become possible due to the high efficiency of the optical elements enabling low dose experiments.

  18. 3 ns single-shot read-out in a quantum dot-based memory structure

    International Nuclear Information System (INIS)

    Nowozin, T.; Bimberg, D.; Beckel, A.; Lorke, A.; Geller, M.

    2014-01-01

    Fast read-out of two to six charges per dot from the ground and first excited state in a quantum dot (QD)-based memory is demonstrated using a two-dimensional electron gas. Single-shot measurements on modulation-doped field-effect transistor structures with embedded InAs/GaAs QDs show read-out times as short as 3 ns. At low temperature (T = 4.2 K) this read-out time is still limited by the parasitics of the setup and the device structure. Faster read-out times and a larger read-out signal are expected for an improved setup and device structure

  19. Method for single-shot measurement of picosecond laser pulse-lengths without electronic time dispersion

    International Nuclear Information System (INIS)

    Kyrala, G.A.

    1987-01-01

    A two-source shear pattern recording is proposed as a method for single-shot measurement of the pulse shape from nearly monochromatic sources whose pulse lengths are shorter than their coherence times. The basis of this method relies on the assertion that if two identical electromagnetic pulses are recombined with a time delay greater than the sum of their pulse widths, the recordable spatial pattern has no fringes in it. At an arbitrary delay, translated into an actual spatial recording position, the recorded modulated intensity will sample the corresponding laser intensity at that delay time, but with a modulation due to the coherence function of the electromagnetic pulse. Two arrangements are proposed for recording the pattern. The principles, the design parameters, and the methodologies of these arrangements are presented. Resolutions of the configurations and their limitations are given as well

  20. Spontaneous mechanical and electrical activities of human calf musculature at rest assessed by repetitive single-shot diffusion-weighted MRI and simultaneous surface electromyography.

    Science.gov (United States)

    Schwartz, Martin; Steidle, Günter; Martirosian, Petros; Ramos-Murguialday, Ander; Preißl, Hubert; Stemmer, Alto; Yang, Bin; Schick, Fritz

    2018-05-01

    Assessment of temporal and spatial relations between spontaneous mechanical activities in musculature (SMAM) at rest as revealed by diffusion-weighted imaging (DWI) and electrical muscular activities in surface EMG (sEMG). Potential influences of static and radiofrequency magnetic fields on muscular activity on sEMG measurements at rest were examined systematically. Series of diffusion-weighted stimulated echo planar imaging were recorded with concurrent sEMG measurements. Electrical activities in sEMG were analyzed by non-parametric Friedman and two-sample Kolmogorov-Smirnov test. Direct correlation of both modalities was investigated by temporal mapping of electrical activity in sEMG to DWI repetition interval. Electrical activities in sEMG and number of visible SMAMs in DWI showed a strong correlation (ρ = 0.9718). High accordance between sEMG activities and visible SMAMs in DWI in a near-surface region around sEMG electrodes was achieved. Characteristics of sEMG activities were almost similar under varying magnetic field conditions. Visible SMAMs in DWI have shown a close and direct relation to concurrent signals recorded by sEMG. MR-related magnetic fields had no significant effects on findings in sEMG. Hence, appearance of SMAMs in DWI should not be considered as imaging artifact or as effects originating from the special conditions of MR examinations. Spatial and temporal distributions of SMAMs indicate characteristics of spontaneous (microscopic) mechanical muscular action at rest. Therefore, DWI techniques should be considered as non-invasive tools for studying physiology and pathophysiology of spontaneous activities in resting muscle. Magn Reson Med 79:2784-2794, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  1. Modelling single shot damage thresholds of multilayer optics for high-intensity short-wavelength radiation sources

    NARCIS (Netherlands)

    Loch, R.A.; Sobierajski, R.; Louis, Eric; Bosgra, J.; Bosgra, J.; Bijkerk, Frederik

    2012-01-01

    The single shot damage thresholds of multilayer optics for highintensity short-wavelength radiation sources are theoretically investigated, using a model developed on the basis of experimental data obtained at the FLASH and LCLS free electron lasers. We compare the radiation hardness of commonly

  2. Quantitative analysis of the breath-holding half-Fourier acquisition single-shot turbo spin-echo technique in abdominal MRI

    Science.gov (United States)

    Dong, Kyung-Rae; Goo, Eun-Hoe; Lee, Jae-Seung; Chung, Woon-Kwan

    2013-01-01

    A consecutive series of 50 patients (28 males and 22 females) who underwent hepatic magnetic resonance imaging (MRI) from August to December 2011 were enrolled in this study. The appropriate parameters for abdominal MRI scans were determined by comparing the images (TE = 90 and 128 msec) produced using the half-Fourier acquisition single-shot turbo spin-echo (HASTE) technique at different signal acquisition times. The patients consisted of 15 normal patients, 25 patients with a hepatoma and 10 patients with a hemangioma. The TE in a single patient was set to either 90 msec or 128 msec. This was followed by measurements using the four normal rendering methods of the biliary tract system and the background signal intensity using the maximal signal intensity techniques in the liver, spleen, pancreas, gallbladder, fat, muscles and hemangioma. The signal-to-noise and the contrast-to-noise ratios were obtained. The image quality was assessed subjectively, and the results were compared. The signal-to-noise and the contrast-to-noise ratios were significantly higher at TE = 128 msec than at TE = 90 when diseases of the liver, spleen, pancreas, gallbladder, and fat and muscles, hepatocellular carcinomas and hemangiomas, and rendering the hepatobiliary tract system based on the maximum signal intensity technique were involved (p breath-hold half-Fourier acquisition single-shot turbo spin-echo (HASTE) was found to be effective in illustrating the abdominal organs for TE = 128 msec. Overall, the image quality at TE = 128 msec was better than that at TE = 90 msec due to the improved signal-to-noise (SNR) and contrast-to-noise (CNR) ratios. Overall, the HASTE technique for abdominal MRI based on a high-magnetic field (3.0 T) at a TE of 128 msec can provide useful data.

  3. Characterization of Soft Tissue Tumors by Diffusion-Weighted Imaging

    International Nuclear Information System (INIS)

    Pekcevik, Yeliz; Kahya, Mehmet Onur; Kaya, Ahmet

    2015-01-01

    Diffusion-weighted imaging (DWI) is a noninvasive method for investigation of tumor histological content. It has been applied for some musculoskeletal tumors and reported to be useful. The aim of the present study was to prospectively evaluate the apparent diffusion coefficient (ADC) values of benign and malignant soft tissue tumors and to determine if ADC can help differentiate these tumors. DWI was performed on 25 histologically proven soft tissue masses. It was obtained with a single-shot echo-planar imaging technique using a 1.5T magnetic resonance (MR) machine. The mean ADC values were calculated. We grouped soft tissue tumors as benign cystic, benign solid or mixed, malignant cystic and malignant solid or mixed tumors and compared mean ADC values between these groups. There was only one patient with a malignant cystic tumor and was not included in the statistical analysis. The median ADC values of benign and malignant tumors were 2.31 ± 1.29 and 0.90 ± 0.70 (median ± interquartile range), respectively. The mean ADC values were different between benign and malignant tumors (P = 0.031). Benign cystic tumors had significantly higher ADC values than benign solid or mixed tumors and malignant solid or mixed tumors (p values were < 0.001 and 0.003, respectively). Malignant solid or mixed tumors had lower ADC values than benign solid or mixed tumors (P = 0.02). Our preliminary results have shown that although there is some overlap between benign and malignant tumors, adding DWI, MR imaging to routine soft tissue tumor protocols may improve diagnostic accuracy

  4. Truly work-like work extraction via a single-shot analysis.

    Science.gov (United States)

    Aberg, Johan

    2013-01-01

    The work content of non-equilibrium systems in relation to a heat bath is often analysed in terms of expectation values of an underlying random work variable. However, when optimizing the expectation value of the extracted work, the resulting extraction process is subject to intrinsic fluctuations, uniquely determined by the Hamiltonian and the initial distribution of the system. These fluctuations can be of the same order as the expected work content per se, in which case the extracted energy is unpredictable, thus intuitively more heat-like than work-like. This raises the question of the 'truly' work-like energy that can be extracted. Here we consider an alternative that corresponds to an essentially fluctuation-free extraction. We show that this quantity can be expressed in terms of a one-shot relative entropy measure introduced in information theory. This suggests that the relations between information theory and statistical mechanics, as illustrated by concepts like Maxwell's demon, Szilard engines and Landauer's principle, extends to the single-shot regime.

  5. Single-shot readout of multiple nuclear spin qubits in diamond under ambient conditions

    Science.gov (United States)

    Jacques, Vincent

    2013-03-01

    Nuclear spins are attractive candidates for solid-state quantum information storage and processing owing to their extremely long coherence time. However, since this appealing property results from a high level of isolation from the environment, it remains a challenging task to polarize, manipulate and readout with high fidelity individual nuclear spins. A promising approach to overcome this limitation consists in utilizing an ancillary single electronic spin to detect and control remote nuclear spins coupled by hyperfine interaction. In this talk, I will show how the electronic spin of a single Nitrogen-Vacancy (NV) defect in diamond can be used as a robust platform to observe the real-time evolution of surrounding single nuclear spins under ambient conditions. Using a diamond sample with a natural abundance of 13C isotopes, we first demonstrate high fidelity initialization and single-shot readout of an individual 13C nuclear spin. By including the intrinsic 14N nuclear spin of the NV defect in the quantum register, we then report the simultaneous observation of quantum jumps linked to both nuclear spin species, providing an efficient initialization of the two qubits. These results open up new avenues for diamond-based quantum information processing (QIP) including active feedback in quantum error correction protocols and tests of quantum correlations with solid-state single spins at room temperature.

  6. Single shot, double differential spectral measurements of inverse Compton scattering in the nonlinear regime

    Directory of Open Access Journals (Sweden)

    Y. Sakai

    2017-06-01

    Full Text Available Inverse Compton scattering (ICS is a unique mechanism for producing fast pulses—picosecond and below—of bright photons, ranging from x to γ rays. These nominally narrow spectral bandwidth electromagnetic radiation pulses are efficiently produced in the interaction between intense, well-focused electron and laser beams. The spectral characteristics of such sources are affected by many experimental parameters, with intense laser effects often dominant. A laser field capable of inducing relativistic oscillatory motion may give rise to harmonic generation and, importantly for the present work, nonlinear redshifting, both of which dilute the spectral brightness of the radiation. As the applications enabled by this source often depend sensitively on its spectra, it is critical to resolve the details of the wavelength and angular distribution obtained from ICS collisions. With this motivation, we present an experimental study that greatly improves on previous spectral measurement methods based on x-ray K-edge filters, by implementing a multilayer bent-crystal x-ray spectrometer. In tandem with a collimating slit, this method reveals a projection of the double differential angular-wavelength spectrum of the ICS radiation in a single shot. The measurements enabled by this diagnostic illustrate the combined off-axis and nonlinear-field-induced redshifting in the ICS emission process. The spectra obtained illustrate in detail the strength of the normalized laser vector potential, and provide a nondestructive measure of the temporal and spatial electron-laser beam overlap.

  7. Diffusion-weighted MRI of the Prostate: Advantages of Zoomed EPI with Parallel-transmit-accelerated 2D-selective Excitation Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Thierfelder, Kolja M.; Scherr, Michael K.; Weiss, Jakob; Mueller-Lisse, Ullrich G.; Theisen, Daniel [Ludwig-Maximilians-University Hospital Munich, Institute for Clinical Radiology, Munich (Germany); Notohamiprodjo, Mike; Nikolaou, Konstantin [Ludwig-Maximilians-University Hospital Munich, Institute for Clinical Radiology, Munich (Germany); University Hospital Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Dietrich, Olaf [Ludwig-Maximilians-University Hospital Munich, Josef Lissner Laboratory for Biomedical Imaging, Institute for Clinical Radiology, Munich (Germany); Pfeuffer, Josef [Siemens Healthcare, Application Development, Erlangen (Germany)

    2014-12-15

    The purpose of our study was to evaluate the use of 2D-selective, parallel-transmit excitation magnetic resonance imaging (MRI) for diffusion-weighted echo-planar imaging (pTX-EPI) of the prostate, and to compare it to conventional, single-shot EPI (c-EPI). The MRI examinations of 35 patients were evaluated in this prospective study. PTX-EPI was performed with a TX-acceleration factor of 1.7 and a field of view (FOV) of 150 x 90 mm{sup 2}, whereas c-EPI used a full FOV of 380 x 297 mm{sup 2}. Two readers evaluated three different aspects of image quality on 5-point Likert scales. To quantify distortion artefacts, maximum diameters and prostate volume were determined for both techniques and compared to T2-weighted imaging. The zoomed pTX-EPI was superior to c-EPI with respect to overall image quality (3.39 ± 0.62 vs 2.45 ± 0.67) and anatomic differentiability (3.29 ± 0.65 vs 2.41 ± 0.65), each with p < 0.0001. Artefacts were significantly less severe in pTX-EPI (0.93 ± 0.73 vs 1.49 ± 1.08), p < 0.001. The quantitative analysis yielded a higher agreement of pTX-EPI with T2-weighted imaging than c-EPI with respect to coronal (ICCs: 0.95 vs 0.93) and sagittal (0.86 vs 0.73) diameters as well as prostate volume (0.94 vs 0.92). Apparent diffusion coefficient (ADC) values did not differ significantly between the two techniques (p > 0.05). Zoomed pTX-EPI leads to substantial improvements in diffusion-weighted imaging (DWI) of the prostate with respect to different aspects of image quality and severity of artefacts. (orig.)

  8. The single-shot opto-digitizer; L'optoechantillonneur monocoup

    Energy Technology Data Exchange (ETDEWEB)

    Nail, M.; Gibert, Ph. [CEA/DAM-Ile de France, Dept. de Conception et Realisation des Experimentations (DCRE), 91 - Bruyeres-le-Chatel (France); CEA/DAM-Ile de France, Dept. Laser Puissance, DLP, 91 - Bruyeres-Le-Chatel (France)

    2000-07-01

    Laser-plasma experiments need to measure signals provided either by X-ray, photonic or neutronic detector. The measurement should have 50 GHz bandwidth and up to several hundred of Giga-Hertz for sub picosecond plasmas. For this purpose, a 35 GHz single shot opto-digitizer (10 ps risetime) has been studied and built. The device is made up of a 50 ohms microstrip propagation line, periodically lined by 100 sampled gates. The propagation line is long enough to measure a 400 ps duration. The sampling rate is 250 Gsa/s (every 4 ps). The sampled gates are made with fast recombining photo-material and turn on by a subpicosecond laser pulse which is synchronized exactly with the analysed phenomena. Every gate is recording to a storing capacitor. After the recording, every capacitor charge is needed to built the signal that was displayed on the propagation line. The dynamic range of measurement is 47 for the entire device. The device can measure positive or negative signals from 1.5 to 70 Volts. To increase the bandwidth, two another kinds of opto-digitizer were studied: one is a buried stripline with 56 GHz band width, the other a 70 GHz coplanar transmission line. For the purpose of subpicosecond plasmas, a 30 coplanar waveguide opto-digitizer was studied. Characteristics are as followed: window of measurement 40 ps, sampling rate 1 ps, bandwidth 230 GHz. Finally, a bundle of optical fibers was used to propagate the laser beam on semiconductor gates. If the gates are lighted at the same time, i.e. if the optical fibers have the same length, we get a simultaneous addressing. By using different lengths of optical fibers, we can do a sequential addressing. So, the sampling rate becomes a combination of the distance between two adjacent sampled channels, and the difference in length of optical fibers. (author)

  9. Single-shot photonic time-stretch digitizer using a dissipative soliton-based passively mode-locked fiber laser.

    Science.gov (United States)

    Peng, Di; Zhang, Zhiyao; Zeng, Zhen; Zhang, Lingjie; Lyu, Yanjia; Liu, Yong; Xie, Kang

    2018-03-19

    We demonstrate a single-shot photonic time-stretch digitizer using a dissipative soliton-based passively mode-locked fiber laser. The theoretical analysis and simulation results indicate that the dissipative soliton-based optical source with a flat spectrum relieves the envelope-induced signal distortion, and its high energy spectral density helps to improve the signal-to-noise ratio, both of which are favorable for simplifying the optical front-end architecture of a photonic time-stretch digitizer. By employing a homemade dissipative soliton-based passively mode-locked erbium-doped fiber laser in a single-shot photonic time-stretch digitizer, an effective number of bits of 4.11 bits under an effective sampling rate of 100 GS/s is experimentally obtained without optical amplification in the link and pulse envelope removing process.

  10. Comparison of MRI (including SS SE-EPI and SPIO-enhanced MRI) and FDG-PET/CT for the detection of colorectal liver metastases

    NARCIS (Netherlands)

    Coenegrachts, Kenneth; de Geeter, Frank; ter Beek, Leon; Walgraeve, Natascha; Bipat, Shandra; Stoker, Jaap; Rigauts, Hans

    2009-01-01

    Fluoro-18-deoxyglucose positron emission tomography computed tomography (FDG-PET/CT) and magnetic resonance imaging (MRI), including unenhanced single-shot spin-echo echo planar imaging (SS SE-EPI) and small paramagnetic iron oxide (SPIO) enhancement, were compared prospectively for detecting

  11. Single-shot readout of a superconducting flux qubit with a flux-driven Josephson parametric amplifier

    Science.gov (United States)

    Lin, Z. R.; Inomata, K.; Oliver, W. D.; Koshino, K.; Nakamura, Y.; Tsai, J. S.; Yamamoto, T.

    2013-09-01

    We report single-shot readout of a superconducting flux qubit by using a flux-driven Josephson parametric amplifier (JPA). After optimizing the readout power, gain of the JPA, and timing of the data acquisition, we observe the Rabi oscillations with a contrast of 74%, which is mainly limited by the bandwidth of the JPA and the energy relaxation of the qubit. The observation of quantum jumps between the qubit eigenstates under continuous monitoring indicates the nondestructiveness of the readout scheme.

  12. Characterization of chondroid matrix-forming sarcomas: gadolinium-enhanced and diffusion weighted MR imaging

    International Nuclear Information System (INIS)

    Cheng Kebin; Zhang Jing; Qu Hui; Zhang Wei; Liang Wei; Li Xiaosong; Cheng Xiaoguang; Gong Lihua

    2010-01-01

    Objective: To study the Gadolinium-enhanced MRI and diffusion weighted imaging (DWI) characteristics of the chondroid matrix-forming sarcomas. Methods: Contrast-enhanced MRI and DWI were performed in 14 cases of chondroid matrix-forming sarcomas (10 chondrosarcomas, 4 chondroblastic osteosarcomas) and 13 cases of other types of osteosarcomas. DWI was obtained with a single-shot echo-planar imaging (EPI) sequence using a 1.5 T MR imager with two different b values of 0 and 700 s/mm 2 . The apparent diffusion coefficient (ADC) values were obtained in GE Functiontool software. The contrast-enhancement pattern was evaluated and the ADC values of chondroid matrix-forming sarcomas was compared with that of other types of osteosareoma. Independent sample t-test was performed to evaluate the difference of ADC values between the group of chondroid matrix-forming sarcoma and the group of other types of osteosarcoma. In addition, nonparametric test was used to assess the difference of ADC values between the chondrosarcoma and the chondroblastic osteosarcoma. P value less than 0.05 was considered to represent a statistical significance. Results: For 14 cases of chondroid matrix-forming sarcomas, peripheral enhancement was found in all cases, septonodular enhancement was identified in 12 cases. While 13 cases of other types of osteosarcomas demonstrated heterogeneous enhancement. The mean ADC value of chondroid matrix-forming sarcomas [(2.56±0.35) x 10 -3 mm 2 /s] was significantly higher than that of other types of osteosarcoma [(1.16 ± 0.20) x 10 -3 mm 2 /s] (t=12.704, P<0.01). There was no significant difference in the ADC value between the chondrosarcoma and the chondroblastic osteosarcoma (Z=0.507, P=0.959). Conclusion: Contrast-enhanced MRI and DWI can improve differentiation between chondroid matrix-forming sarcomas and other types of osteosarcomas. (authors)

  13. Role of EPI in diagnosing cavernous hemangioma and small HCC : comparison with fast T2-weighted MR Imaging

    International Nuclear Information System (INIS)

    Kim, Suk; Lee, Jun Woo; Kim, Chang Won; Jung, Hyun Woo; Choi, Sang Yoel; Lee, Suck Hong; Kim, Byung Soo

    1998-01-01

    The purpose of this study is to compare single-shot echo-planar MR imaging (EPI) with breath-hold fast T2-weighted imaging (HASTE or Turbo spin-echo T2WI) for evaluation of the role of EPI in distinguishing small hepatocellular carcinoma from cavernous hemangioma. We retrospectively evaluated MR images of 35 patients (21 cases of small HCC and 14 cases of cavernous hemangioma). EPI and breath-hold fast T2WI images were obtained and compared on the basis of lesion detection sensitivity, lesion-to-liver signal intensity ratio (SIR), contrast ratio (CR), and lesion-to-liver contrast to noise ratio (CNR). For the detection of small HCC, the sensitivity of EPI and breath-hold fast T2WI were equal in 14 of 21 cases (71.4%). The detection sensitivity of cavernous hemangioma with EPI and breath-hold fast T2WI was 100 % (14/14). Mean SIR on breath-hold fast T2WI was 2.02 ± 0.45 for small HCC and 3.65 ± 0.97 for cavernous hemangioma; on EPI, the corresponding figures were 2.91 ± 0.57 for cavernous hemangioma; On EPI, the figures obtained were 2.27 ± 0.52 and 6.26 ± 2.19, respectively. Mean CNR on breath-hold fast T2WI was 14.24 ± 4.098 for small HCC and 50.28 ± 10.96 for cavernous hemangioma, while on EPI, the corresponding figures were 13.84 ± 3.02 and 45.44 ± 11.21. In detecting focal hepatic mass, the sensitivity of EPI and breath-hold fast T2WI are comparable for the diagnosis of small HCC and cavernous hemangioma, EPI can provided additional information. (author). 20 refs., 2 tabs., 4 figs

  14. Analysis of the diffusion tensor imaging parameters of a normal cervical spinal cord in a healthy population.

    Science.gov (United States)

    Wei, Liang-Feng; Wang, Shou-Sen; Zheng, Zhao-Cong; Tian, Jun; Xue, Liang

    2017-05-01

    Diffusion tensor imaging (DTI) shows great advantage in the diagnosis of brain diseases, including cervical spinal cord (CSC) disease. This study aims to obtain the normal values of the DTI parameters for a healthy population and to establish a baseline for CSC disease diagnosis using DTI. A total of 36 healthy adults were subjected to magnetic resonance imaging (MRI) for the entire CSC using the Siemens 3.0 T MR System. Sagittal DTI acquisition was carried out with a single-shot spin-echo echo-planar imaging (EPI) sequence along 12 non-collinear directions. Fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values were determined at different cervical levels using a region of interest (ROI) method, following which they were correlated with parameters, like age and sex. Further, diffusion tensor tracking (DTT) was carried out to reconstruct the white matter fiber bundles of the CSC. The full and complete fiber bundle structure of a normal CSC was confirmed in both the T2-weighted and DTI images. The FA and ADC values were significantly negatively correlated with each other and showed strongly negative and positive correlations with age, respectively, but not with sex. Additionally, there was no significant difference between the FA and the ADC values at different cervical levels. The DTI technique can act as an important supplement to the conventional MRI technique for CSC observation. Moreover, the FA and ADC values can be used as sensitive parameters in the DTI study on the CSC by taking the effects of age into consideration.

  15. [In-phase and out-of-phase single-shot magnetization-prepared gradient recalled echo: description and optimization of technique at 1.5 T].

    Science.gov (United States)

    Ramalho, M; Herédia, V; de Campos, R O P; de Toni, M; Dale, B M; Semelka, R C

    2014-01-01

    To implement in-phase and out-of-phase (IP/OP) techniques with Magnetization-Prepared Gradient Recalled Echo (MP-GRE) and to evaluate the feasibility and diagnostic image quality among pre and post-optimized MP-GRE sequences, including patients unable to cooperate with breath-hold requirements. Institutional review board approval with waiver of informed consent was obtained for this HIPAA-compliant retrospective study. Two groups of patients were included in the study, before and after optimization of MP-GRE parameters, with seventy-three (24 noncooperative/49 cooperative) and sixty-four (22 noncooperative/42 cooperative) consecutive patients, respectively. The motion-insensitive sequence used in this study was a single-shot 2D MP-GRE. Two radiologists qualitatively evaluated the sequences to identify the presence of phase cancellation artifact in OP images and to determine image quality, extent of artifacts (respiratory ghosting, bounce-point artifact, spatial misregistration and pixel graininess) and lesion conspicuity on the various sequences. The ability to visually detect liver steatosis and fatty adrenal adenomas was evaluated. Qualitative analyses were compared using the Wilcoxon and Mann-Whitney tests. There were statistically significant differences between all MP-GRE sequences concerning phase cancellation artifact (P<.0001) which was present in MP-GRE OP sequences and negligible to absent in the pre (IP1) and post-optimized (IP2) MP-GRE IP sequences, respectively, in all patients. Bounce point artifacts were significantly more pronounced in MP-GRE IP1 (P<.0001). Spatial misregistration was slightly more prominent in noncooperative patients with MP-GRE IP2 (P=.0027). MP-GRE OP and MP-GRE IP2 showed significantly higher overall image quality (P<.0001). MP-GRE sequences subjectively identified hepatic steatosis (n=20) and adrenal adenomas (n=5) based on signal loss from IP to OP sequence. Single shot IP/OP MP-GRE is feasible and allows motion resistant

  16. Pharmaceutical and immunological evaluation of a single-shot hepatitis B vaccine formulated with PLGA microspheres.

    Science.gov (United States)

    Shi, Li; Caulfield, Michael J; Chern, Rey T; Wilson, Roger A; Sanyal, Gautam; Volkin, David B

    2002-04-01

    A single-shot Hepatitis B vaccine formulation using poly(d,l)-lactide-co-glycolide acid (PLGA) microspheres as a delivery system was examined using a variety of biophysical and biochemical techniques as well as immunological evaluation in C3H mice. PLGA microsphere encapsulation of the Hepatitis B surface antigen (HBsAg), a lipoprotein particle, resulted in good recoveries of protein mass, protein particle conformational integrity, and in vitro antigenicity. Some partial delipidation of the HBsAg, however, was observed. The loading and encapsulation efficiency of HBsAg into the PLGA microspheres were measured along with the morphology and size distribution of the vaccine-loaded PLGA microspheres. The in vitro release kinetics of HBsAg from the PLGA microspheres was evaluated and found to be affected by experimental conditions such as stirring rate. HBsAg showed enhanced storage stability at 37 degrees C in the slightly acidic pH range reported to be found inside PLGA microspheres; thus, the antigen is relatively stable under conditions of temperature and pH that may mimic in vivo conditions. The immunogenicity of the microsphere formulations of HBsAg was compared with conventional aluminum adjuvant formulated HBsAg vaccine in C3H mice. Comparisons were made between aluminum formulations (one and two injections), PLGA microsphere formulations (single injection), and a mixture of aluminum and PLGA microsphere formulations (single injection). The nine-month serum antibody titers indicate that a single injection of a mixture of aluminum and PLGA-formulated HBsAg results in equal or better immune responses than two injections of aluminum-formulated HBsAg vaccine. Based on these in vitro and in vivo studies, it is concluded that HBsAg can be successfully encapsulated and recovered from the PLGA microspheres and a mixture of aluminum-adjuvanted and PLGA-formulated HBsAg can auto-boost an immune response in manner comparable to multiple injections of an aluminum

  17. Signal-shot echo-planner diffusion-weighted MR imaging at 3T and 1.5T for differentiation of benign vertebral fracture edema and tumor infiltration

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hee Jin; Lee, So Yeon; Rho, Myung Ho; Chung, Eun Chul; Kim, Mi Sung; Kwon, Heon Ju; Youn, In Young [Dept. of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2016-09-15

    To compare the apparent diffusion coefficient (ADC) value using single-shot echo-planar imaging sequences at 3T and 1.5T for differentiation of benign fracture edema and tumor infiltration of the vertebral body. A total of 46 spinal examinations were included in the 1.5T MRI group, and a total of 40 spinal examinations were included in the 3T MRI group. The ADC values of the lesion were measured and calculated. The diagnostic performance of the conventional MR image containing sagittal T2-weighted fat saturated image and each diffusion weighted image (DWI) with an ADC value with different b values were evaluated. The mean ADC value of the benign lesions was higher than that of the malignant lesions on 1.5T and 3T (p < 0.05). The sensitivity of the diagnostic performance was higher with an additional DWI in both 1.5T and 3T, but the sensitivities were similar with the addition of b values of 400 and 1000. The specificities of the diagnostic performances did not show significant differences (p value > 0.05). The diagnostic accuracies were higher when either of the DWIs (b values of 400 and 1000) was added to routine MR image for 1.5T and 3T. Statistical differences between 1.5T and 3T or between b values of 400 and 1000 were not seen. The ADC values of the benign lesions were significantly higher than those of the malignant lesions on 1.5T and 3T. There was no statistically significant difference in the diagnostic performances when either of the DWIs (b values of 400 and 1000) was added to the routine MR image for 1.5T and 3T.

  18. Diffusion tensor imaging and fiber tractography in cervical compressive myelopathy: preliminary results

    International Nuclear Information System (INIS)

    Lee, Joon Woo; Kim, Jae Hyoung; Park, Jong Bin; Lee, Guen Young; Kang, Heung Sik; Park, Kun Woo; Yeom, Jin S.

    2011-01-01

    To assess diffusion tensor imaging (DTI) parameters in cervical compressive myelopathy (CCM) patients compared to normal volunteers, to relate them with myelopathy severity, and to relate tractography patterns with postoperative neurologic improvement. Twenty patients suffering from CCM were prospectively enrolled (M:F = 13:7, mean age, 49.6 years; range 22-67 years) from September 2009 to March 2010. Sensitivity encoding (SENSE) single-shot echo-planar imaging (EPI) was used for the sagittal DTI. Twenty sex- and age-matched normal volunteers underwent the same scanning procedure. Fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values in the spinal cord were compared between the patients and normal volunteers and were related to myelopathy severity based on Japanese Orthopedic Association (JOA) scores. Tractography patterns were related to myelopathy severity and postoperative improvement. There were significant differences between patients and normal volunteers in terms of FA (0.498 ± 0.114 vs. 0.604 ± 0.057; p = 0.001) and ADC (1.442 ± 0.389 vs. 1.169 ± 0.098; p = 0.001). DTI parameters and tractography patterns were not related to myelopathy severity. In ten patients in the neurologically worse group, postoperative neurologic improvement was seen in four of five patients with intact fiber tracts, but only one of five patients with interrupted fiber tracts exhibited neurologic improvement. DTI parameters in CCM patients were significantly different from those in normal volunteers but were not significantly related to myelopathy severity. The patterns of tractography appear to correlate with postoperative neurologic improvement. (orig.)

  19. Value of 3 Tesla diffusion-weighted magnetic resonance imaging for assessing liver fibrosis.

    Science.gov (United States)

    Papalavrentios, Lavrentios; Sinakos, Emmanouil; Chourmouzi, Danai; Hytiroglou, Prodromos; Drevelegas, Konstantinos; Constantinides, Manos; Drevelegas, Antonios; Talwalkar, Jayant; Akriviadis, Evangelos

    2015-01-01

    Limited data are available regarding the role of magnetic resonance imaging (MRI), particularly the new generation 3 Tesla technology, and especially diffusion-weighted imaging (DWI) in predicting liver fibrosis. The aim of our pilot study was to assess the clinical performance of the apparent diffusion coefficient (ADC) of liver parenchyma for the assessment of liver fibrosis in patients with non-alcoholic fatty liver disease (NAFLD). 18 patients with biopsy-proven NAFLD underwent DWI with 3 Tesla MRI. DWI was performed with single-shot echo-planar technique at b values of 0-500 and 0-1000 s/mm 2 . ADC was measured in four locations in the liver and the mean ADC value was used for analysis. Staging of fibrosis was performed according to the METAVIR system. The median age of patients was 52 years (range 23-73). The distribution of patients in different fibrosis stages was: 0 (n=1), 1 (n=7), 2 (n=1), 3 (n=5), 4 (n=4). Fibrosis stage was poorly associated with ADC at b value of 0-500 s/mm 2 (r= -0.30, P=0.27). However it was significantly associated with ADC at b value of 0-1000 s/mm 2 (r= -0.57, P=0.01). For this b value (0-1000 s/mm 2 ) the area under receiver-operating characteristic curve was 0.93 for fibrosis stage ≥3 and the optimal ADC cut-off value was 1.16 ×10 -3 mm 2 /s. 3 Tesla DWI can possibly predict the presence of advanced fibrosis in patients with NAFLD.

  20. Apparent diffusion coefficient value of gastric cancer by diffusion-weighted imaging: Correlations with the histological differentiation and Lauren classification

    International Nuclear Information System (INIS)

    Liu, Song; Guan, Wenxian; Wang, Hao; Pan, Liang; Zhou, Zhuping; Yu, Haiping; Liu, Tian; Yang, Xiaofeng; He, Jian; Zhou, Zhengyang

    2014-01-01

    Highlights: • Gastric cancers’ ADC values were significantly lower than normal gastric wall. • Gastric adenocarcinomas with different differentiation had different ADC values. • Gastric adenocarcinomas’ ADC values correlated with histologic differentiations. • Gastric cancers’ ADC values correlated with Lauren classifications. • Mean ADC value was better than min ADC value in characterizing gastric cancers. - Abstract: Objective: The purpose of this study was to evaluate the correlations between histological differentiation and Lauren classification of gastric cancer and the apparent diffusion coefficient (ADC) value of diffusion weighted imaging (DWI). Materials and methods: Sixty-nine patients with gastric cancer lesions underwent preoperative magnetic resonance imaging (MRI) (3.0T) and surgical resection. DWI was obtained with a single-shot, echo-planar imaging sequence in the axial plane (b values: 0 and 1000 s/mm 2 ). Mean and minimum ADC values were obtained for each gastric cancer and normal gastric walls by two radiologists, who were blinded to the histological findings. Histological type, degree of differentiation and Lauren classification of each resected specimen were determined by one pathologist. Mean and minimum ADC values of gastric cancers with different histological types, degrees of differentiation and Lauren classifications were compared. Correlations between ADC values and histological differentiation and Lauren classification were analyzed. Results: The mean and minimum ADC values of gastric cancers, as a whole and separately, were significantly lower than those of normal gastric walls (all p values <0.001). There were significant differences in the mean and minimum ADC values among gastric cancers with different histological types, degrees of differentiation and Lauren classifications (p < 0.05). Mean and minimum ADC values correlated significantly (all p < 0.001) with histological differentiation (r = 0.564, 0.578) and Lauren

  1. Apparent diffusion coefficient value of gastric cancer by diffusion-weighted imaging: Correlations with the histological differentiation and Lauren classification

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Song, E-mail: songliu532909756@gmail.com [Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008 (China); Guan, Wenxian, E-mail: wenxianguan123@126.com [Department of Gastrointestinal Surgery, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008 (China); Wang, Hao, E-mail: wanghao20140525@126.com [Department of Gastrointestinal Surgery, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008 (China); Pan, Liang, E-mail: panliang2014@126.com [Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008 (China); Zhou, Zhuping, E-mail: zhupingzhou@126.com [Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008 (China); Yu, Haiping, E-mail: haipingyu2012@126.com [Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008 (China); Liu, Tian, E-mail: tianliu2014@126.com [Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322 (United States); Yang, Xiaofeng, E-mail: xiaofengyang2014@126.com [Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322 (United States); He, Jian, E-mail: hjxueren@126.com [Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008 (China); Zhou, Zhengyang, E-mail: zyzhou@nju.edu.cn [Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008 (China)

    2014-12-15

    Highlights: • Gastric cancers’ ADC values were significantly lower than normal gastric wall. • Gastric adenocarcinomas with different differentiation had different ADC values. • Gastric adenocarcinomas’ ADC values correlated with histologic differentiations. • Gastric cancers’ ADC values correlated with Lauren classifications. • Mean ADC value was better than min ADC value in characterizing gastric cancers. - Abstract: Objective: The purpose of this study was to evaluate the correlations between histological differentiation and Lauren classification of gastric cancer and the apparent diffusion coefficient (ADC) value of diffusion weighted imaging (DWI). Materials and methods: Sixty-nine patients with gastric cancer lesions underwent preoperative magnetic resonance imaging (MRI) (3.0T) and surgical resection. DWI was obtained with a single-shot, echo-planar imaging sequence in the axial plane (b values: 0 and 1000 s/mm{sup 2}). Mean and minimum ADC values were obtained for each gastric cancer and normal gastric walls by two radiologists, who were blinded to the histological findings. Histological type, degree of differentiation and Lauren classification of each resected specimen were determined by one pathologist. Mean and minimum ADC values of gastric cancers with different histological types, degrees of differentiation and Lauren classifications were compared. Correlations between ADC values and histological differentiation and Lauren classification were analyzed. Results: The mean and minimum ADC values of gastric cancers, as a whole and separately, were significantly lower than those of normal gastric walls (all p values <0.001). There were significant differences in the mean and minimum ADC values among gastric cancers with different histological types, degrees of differentiation and Lauren classifications (p < 0.05). Mean and minimum ADC values correlated significantly (all p < 0.001) with histological differentiation (r = 0.564, 0.578) and

  2. Functional magnetic resonance imaging of the primary motor cortex

    Indian Academy of Sciences (India)

    Functional magnetic resonance imaging (fMRI) studies have been performed on 20 right handed volunteers at 1.5 Tesla using echo planar imaging (EPI) protocol. Index finger tapping invoked localized activation in the primary motor area. Consistent and highly reproducible activation in the primary motor area was observed ...

  3. Supplemental single shot femoral nerve block for total hip arthroplasty: impact on early postoperative care, pain management and lung function.

    Science.gov (United States)

    Wiesmann, T; Steinfeldt, T; Wagner, G; Wulf, H; Schmitt, J; Zoremba, M

    2014-01-01

    Peripheral regional anesthesia is beneficial in the management of postoperative pain in hip surgery, and can also reduce post-operative care unit (PACU) stay. Its opioid-sparing actions may also be beneficial for respiratory mechanics and pulmonary function. The aim of our pilot study was to evaluate the effect of a supplemental single shot femoral block for elective total hip arthroplasty on early respiratory function and postoperative management within the first 24 postoperative hours. We prospectively studied 80 patients undergoing total hip arthroplasty. Written informed consent was obtained after ethics committee approval. Forty patients were randomLy assigned to receive single shot femoral nerve block (FNB) using 15mL bupivacaine 0.25% and 20 mg clonidine while the remainder received standard treatment without nerve block (STN). Premedication and general anesthesia were standardized. Pulse oximetry saturation and spirometric lung function were measured preoperatively (baseline) and at 0.5 h, 2 h, 6 h and 24 h, after extubation breathing room air. PACU surveillance and postoperative pain therapy was standardized. Oxygen saturation and spirometry results were significantly better within the FNB group during the first six postoperative hours. Although VAS scores during the PACU stay did not significantly differ between the study groups, PACU discharge criteria were met earlier in the FNB group (116±40 min [mean±SD] vs. 152±47 min in the STN group). The FNB group exhibited significantly lower VAS scores at 6 and 24 hours. Supplemental single shot femoral nerve block for total hip arthroplasty resulted in earlier PACU discharge capability, improved lung function during the first six hours and better pain control within the first 24 postoperative hours.

  4. Nonenhanced ECG-gated quiescent-interval single-shot MRA (QISS-MRA) of the lower extremities: Comparison with contrast-enhanced MRA

    Energy Technology Data Exchange (ETDEWEB)

    Klasen, J. [Department of Diagnostic and Interventional Radiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Blondin, D., E-mail: blondin@med.uni-duesseldorf.de [Department of Diagnostic and Interventional Radiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Schmitt, P. [Siemens AG, Healthcare Sector, Erlangen (Germany); Bi, X. [Siemens Healthcare, Chicago, IL (United States); Sansone, R. [Department of Cardiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Wittsack, H.-J.; Kroepil, P.; Quentin, M.; Kuhlemann, J.; Miese, F. [Department of Diagnostic and Interventional Radiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Heiss, C.; Kelm, M. [Department of Cardiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Antoch, G.; Lanzman, R.S. [Department of Diagnostic and Interventional Radiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany)

    2012-05-15

    Aim: To evaluate electrocardiogram (ECG)-gated quiescent-interval single-shot magnetic resonance angiography (QISS-MRA) for nonenhanced assessment of peripheral artery occlusive disease (PAOD) using contrast-enhanced MRA (CE-MRA) as the reference standard. Materials and methods: Twenty-seven patients (mean age 66.6 {+-} 10.8 years) with PAOD were included in the study. QISS-MRA and CE-MRA of the lower extremity were performed using a 1.5 T MR scanner. In each patient, subjective image quality and the degree of stenosis were evaluated on a four-point scale for 15 predefined arterial segments. Results: Twenty-five of the 27 patients were considered for analysis. Subjective image quality of QISS-MRA was significantly lower for the distal aorta, pelvic arteries, and femoral arteries as compared to CE-MRA (p < 0.01), while no significant difference was found for other vascular segments. The degree of stenosis was overestimated with QISS-MRA in 23 of 365 (6.3%) segments and underestimated in two of 365 (0.5%) segments. As compared to CE-MRA, QISS-MRA had a high sensitivity (98.6%), specificity (96%) as well as positive and negative predictive value (88.7 and 99.6%, respectively) for the detection of significant stenosis ({>=}50%). Conclusion: ECG-gated QISS-MRA is a promising imaging technique for reliable assessment of PAOD without the use of contrast material.

  5. Nonenhanced ECG-gated quiescent-interval single-shot MRA (QISS-MRA) of the lower extremities: Comparison with contrast-enhanced MRA

    International Nuclear Information System (INIS)

    Klasen, J.; Blondin, D.; Schmitt, P.; Bi, X.; Sansone, R.; Wittsack, H.-J.; Kröpil, P.; Quentin, M.; Kuhlemann, J.; Miese, F.; Heiss, C.; Kelm, M.; Antoch, G.; Lanzman, R.S.

    2012-01-01

    Aim: To evaluate electrocardiogram (ECG)-gated quiescent-interval single-shot magnetic resonance angiography (QISS-MRA) for nonenhanced assessment of peripheral artery occlusive disease (PAOD) using contrast-enhanced MRA (CE-MRA) as the reference standard. Materials and methods: Twenty-seven patients (mean age 66.6 ± 10.8 years) with PAOD were included in the study. QISS-MRA and CE-MRA of the lower extremity were performed using a 1.5 T MR scanner. In each patient, subjective image quality and the degree of stenosis were evaluated on a four-point scale for 15 predefined arterial segments. Results: Twenty-five of the 27 patients were considered for analysis. Subjective image quality of QISS-MRA was significantly lower for the distal aorta, pelvic arteries, and femoral arteries as compared to CE-MRA (p < 0.01), while no significant difference was found for other vascular segments. The degree of stenosis was overestimated with QISS-MRA in 23 of 365 (6.3%) segments and underestimated in two of 365 (0.5%) segments. As compared to CE-MRA, QISS-MRA had a high sensitivity (98.6%), specificity (96%) as well as positive and negative predictive value (88.7 and 99.6%, respectively) for the detection of significant stenosis (≥50%). Conclusion: ECG-gated QISS-MRA is a promising imaging technique for reliable assessment of PAOD without the use of contrast material.

  6. Observation of Quantum Jumps of a Single Quantum Dot Spin Using Submicrosecond Single-Shot Optical Readout

    Science.gov (United States)

    Delteil, Aymeric; Gao, Wei-bo; Fallahi, Parisa; Miguel-Sanchez, Javier; Imamoǧlu, Atac

    2014-03-01

    Single-shot readout of individual qubits is typically the slowest process among the elementary single- and two-qubit operations required for quantum information processing. Here, we use resonance fluorescence from a single-electron charged quantum dot to read out the spin-qubit state in 800 nanoseconds with a fidelity exceeding 80%. Observation of the spin evolution on longer time scales reveals quantum jumps of the spin state: we use the experimentally determined waiting-time distribution to characterize the quantum jumps.

  7. Single shot fringe pattern phase demodulation using Hilbert-Huang transform aided by the principal component analysis.

    Science.gov (United States)

    Trusiak, Maciej; Służewski, Łukasz; Patorski, Krzysztof

    2016-02-22

    Hybrid single shot algorithm for accurate phase demodulation of complex fringe patterns is proposed. It employs empirical mode decomposition based adaptive fringe pattern enhancement (i.e., denoising, background removal and amplitude normalization) and subsequent boosted phase demodulation using 2D Hilbert spiral transform aided by the Principal Component Analysis method for novel, correct and accurate local fringe direction map calculation. Robustness to fringe pattern significant noise, uneven background and amplitude modulation as well as local fringe period and shape variations is corroborated by numerical simulations and experiments. Proposed automatic, adaptive, fast and comprehensive fringe analysis solution compares favorably with other previously reported techniques.

  8. Optimization of laser energy deposition for single-shot high aspect-ratio microstructuring of thick BK7 glass

    Energy Technology Data Exchange (ETDEWEB)

    Garzillo, Valerio; Grigutis, Robertas [Dipartimento di Scienza e Alta Tecnologia, University of Insubria, Via Valleggio 11, I-22100 Como (Italy); Jukna, Vytautas [Centre de Physique Theorique, CNRS, Ecole Polytechnique, Université Paris-Saclay, F-91128 Palaiseau (France); LOA, ENSTA-ParisTech, CNRS, Ecole Polytechnique, Université Paris Saclay, F-91762 Palaiseau (France); Couairon, Arnaud [Centre de Physique Theorique, CNRS, Ecole Polytechnique, Université Paris-Saclay, F-91128 Palaiseau (France); Di Trapani, Paolo [Dipartimento di Scienza e Alta Tecnologia, University of Insubria and CNISM UdR Como, Via Valleggio 11, I-22100 Como (Italy); Jedrkiewicz, Ottavia, E-mail: ottavia.jedrkiewicz@ifn.cnr.it [Istituto di Fotonica e Nanotecnologie, CNR and CNISM UdR Como, Via Valleggio 11, I-22100 Como (Italy)

    2016-07-07

    We investigate the generation of high aspect ratio microstructures across 0.7 mm thick glass by means of single shot Bessel beam laser direct writing. We study the effect on the photoinscription of the cone angle, as well as of the energy and duration of the ultrashort laser pulse. The aim of the study is to optimize the parameters for the writing of a regular microstructure due to index modification along the whole sample thickness. By using a spectrally resolved single pulse transmission diagnostics at the output surface of the glass, we correlate the single shot material modification with observations of the absorption in different portions of the retrieved spectra, and with the absence or presence of spectral modulation. Numerical simulations of the evolution of the Bessel pulse intensity and of the energy deposition inside the sample help us interpret the experimental results that suggest to use picosecond pulses for an efficient and more regular energy deposition. Picosecond pulses take advantage of nonlinear plasma absorption and avoid temporal dynamics effects which can compromise the stationarity of the Bessel beam propagation.

  9. Axon diameter and intra-axonal volume fraction of the corticospinal tract in idiopathic normal pressure hydrocephalus measured by q-space imaging.

    Directory of Open Access Journals (Sweden)

    Kouhei Kamiya

    Full Text Available PURPOSE: Previous studies suggest that compression and stretching of the corticospinal tract (CST potentially cause treatable gait disturbance in patients with idiopathic normal pressure hydrocephalus (iNPH. Measurement of axon diameter with diffusion MRI has recently been used to investigate microstructural alterations in neurological diseases. In this study, we investigated alterations in the axon diameter and intra-axonal fraction of the CST in iNPH by q-space imaging (QSI analysis. METHODS: Nineteen patients with iNPH and 10 age-matched controls were recruited. QSI data were obtained with a 3-T system by using a single-shot echo planar imaging sequence with the diffusion gradient applied parallel to the antero-posterior axis. By using a two-component low-q fit model, the root mean square displacements of intra-axonal space ( =  axon diameter and intra-axonal volume fraction of the CST were calculated at the levels of the internal capsule and body of the lateral ventricle, respectively. RESULTS: Wilcoxon's rank-sum test revealed a significant increase in CST intra-axonal volume fraction at the paraventricular level in patients (p<0.001, whereas no significant difference was observed in the axon diameter. At the level of the internal capsule, neither axon diameter nor intra-axonal volume fraction differed significantly between the two groups. CONCLUSION: Our results suggest that in patients with iNPH, the CST does not undergo irreversible axonal damage but is rather compressed and/or stretched owing to pressure from the enlarged ventricle. These analyses of axon diameter and intra-axonal fraction yield insights into microstructural alterations of the CST in iNPH.

  10. Single-shot mega-electronvolt ultrafast electron diffraction for structure dynamic studies of warm dense matter

    Energy Technology Data Exchange (ETDEWEB)

    Mo, M. Z., E-mail: mmo09@slac.stanford.edu; Shen, X.; Chen, Z.; Li, R. K.; Dunning, M.; Zheng, Q.; Weathersby, S. P.; Reid, A. H.; Coffee, R.; Makasyuk, I.; Edstrom, S.; McCormick, D.; Jobe, K.; Hast, C.; Glenzer, S. H.; Wang, X. [SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025 (United States); Sokolowski-Tinten, K. [Faculty of Physics and Centre for Nanointegration Duisburg-Essen, University of Duisburg-Essen, Lotharstrasse 1, D-47048 Duisburg (Germany)

    2016-11-15

    We have developed a single-shot mega-electronvolt ultrafast-electron-diffraction system to measure the structural dynamics of warm dense matter. The electron probe in this system is featured by a kinetic energy of 3.2 MeV and a total charge of 20 fC, with the FWHM pulse duration and spot size at sample of 350 fs and 120 μm respectively. We demonstrate its unique capability by visualizing the atomic structural changes of warm dense gold formed from a laser-excited 35-nm freestanding single-crystal gold foil. The temporal evolution of the Bragg peak intensity and of the liquid signal during solid-liquid phase transition are quantitatively determined. This experimental capability opens up an exciting opportunity to unravel the atomic dynamics of structural phase transitions in warm dense matter regime.

  11. Single-shot spectro-temporal characterization of XUV pulses from a seeded free-electron laser

    Science.gov (United States)

    de Ninno, Giovanni; Gauthier, David; Mahieu, Benoît; Ribič, Primož Rebernik; Allaria, Enrico; Cinquegrana, Paolo; Danailov, Miltcho Bojanov; Demidovich, Alexander; Ferrari, Eugenio; Giannessi, Luca; Penco, Giuseppe; Sigalotti, Paolo; Stupar, Matija

    2015-08-01

    Intense ultrashort X-ray pulses produced by modern free-electron lasers (FELs) allow one to probe biological systems, inorganic materials and molecular reaction dynamics with nanoscale spatial and femtoscale temporal resolution. These experiments require the knowledge, and possibly the control, of the spectro-temporal content of individual pulses. FELs relying on seeding have the potential to produce spatially and temporally fully coherent pulses. Here we propose and implement an interferometric method, which allows us to carry out the first complete single-shot spectro-temporal characterization of the pulses, generated by an FEL in the extreme ultraviolet spectral range. Moreover, we provide the first direct evidence of the temporal coherence of a seeded FEL working in the extreme ultraviolet spectral range and show the way to control the light generation process to produce Fourier-limited pulses. Experiments are carried out at the FERMI FEL in Trieste.

  12. Measurement of the single-shot pulse energy of a free electron laser using a cryogenic radiometer

    Energy Technology Data Exchange (ETDEWEB)

    Masahiro, Kato; Norio, Saito; Yuichiro, Morishita; Takahiro, Tanaka [National Institute of Advanced Industrial Science and Technology (AIST), NMIJ, Tsukuba (Japan); Masahiro, Kato; Norio, Saito; Kai, Tiedtke; Pavle N, Juranic; Sorokin, A.A.; Richter, M.; Takahiro, Tanaka; Mitsuru, Nagasono; Makina, Yabashi; Kensuke, Tono; Tadashi, Togashi; Tetsuya, Ishikawa [RIKEN, XFEL Project Head Office, Kouto, Sayo, Hyogo (Japan); Kai, Tiedtke; Pavle N, Juranic; Sorokin, A.A.; Jastrow, U. [Deutsches Elektronen-Synchrotron, DESY, Hamburg (Germany); Sorokin, A.A. [Ioffe Physico-Technical Institute, Polytekhnicheskaya 26, St Petersburg (Russian Federation); Richter, M.; Kroth, U.; Schoppe, H. [Physikalisch-Technische Bundesanstalt, PTB, Berlin (Germany); Tadashi, Togashi; Hiroaki, Kimura; Haruhiko, Ohashi [Japan Synchrotron Radiation Research Institute, Sayo, Hyogo (Japan)

    2010-10-15

    The absolute single-shot pulse energy of the SPring 8 extreme ultraviolet (EUV) free electron laser (FEL) was measured using a cryogenic radiometer with a relative standard uncertainty of 3%. The temperature change of the cavity in the cryogenic radiometer caused by an incident FEL pulse was determined using a lock-in amplifier and an ac Wheatstone bridge. The measured pulse energies were compared with a gas-monitor detector developed by Physikalisch-Technische Bundesanstalt/Deutsches Elektronen-Synchrotron/Ioffe Physico-Technical Institute (Ioffe) at a wavelength of 51.3 nm at the SPring-8 EUV-FEL in a shot-to-shot mode. The pulse energies measured using the two detectors agree within 2.0%. (authors)

  13. Characterization of temporal coherence of hard X-ray free-electron laser pulses with single-shot interferograms

    Directory of Open Access Journals (Sweden)

    Taito Osaka

    2017-11-01

    Full Text Available Temporal coherence is one of the most fundamental characteristics of light, connecting to spectral information through the Fourier transform relationship between time and frequency. Interferometers with a variable path-length difference (PLD between the two branches have widely been employed to characterize temporal coherence properties for broad spectral regimes. Hard X-ray interferometers reported previously, however, have strict limitations in their operational photon energies, due to the specific optical layouts utilized to satisfy the stringent requirement for extreme stability of the PLD at sub-ångström scales. The work presented here characterizes the temporal coherence of hard X-ray free-electron laser (XFEL pulses by capturing single-shot interferograms. Since the stability requirement is drastically relieved with this approach, it was possible to build a versatile hard X-ray interferometer composed of six separate optical elements to cover a wide photon energy range from 6.5 to 11.5 keV while providing a large variable delay time of up to 47 ps at 10 keV. A high visibility of up to 0.55 was observed at a photon energy of 10 keV. The visibility measurement as a function of time delay reveals a mean coherence time of 5.9 ± 0.7 fs, which agrees with that expected from the single-shot spectral information. This is the first result of characterizing the temporal coherence of XFEL pulses in the hard X-ray regime and is an important milestone towards ultra-high energy resolutions at micro-electronvolt levels in time-domain X-ray spectroscopy, which will open up new opportunities for revealing dynamic properties in diverse systems on timescales from femtoseconds to nanoseconds, associated with fluctuations from ångström to nanometre spatial scales.

  14. Blood Bupivacaine Concentrations After a Combined Single-Shot Sciatic Block and a Continuous Femoral Nerve Block in Pediatric Patients: A Prospective Observational Study.

    Science.gov (United States)

    Suresh, Santhanam; De Oliveira, Gildasio S

    2017-05-01

    We evaluated blood bupivacaine concentrations in children having a single-shot sciatic and continuous femoral blocks after anterior cruciate ligament repair. Dried blood spot samples were analyzed for bupivacaine levels at 0, 5, 15, 30, 60, and 120 minutes and 4, 24, and 48 hours. The highest 99% upper confidence interval limit was 135 ng/mL at the 4-hour evaluation point. The 99% upper confidence interval was below potentially toxic levels (1500 ng/mL) across all sampling times. The risk of local anesthetic toxicity in pediatric patients receiving single-shot sciatic and continuous femoral nerve blocks is very low.

  15. Diffusion weighted MR imaging of pancreatic islet cell tumors

    International Nuclear Information System (INIS)

    Bakir, Baris; Salmaslioglu, Artur; Poyanli, Arzu; Rozanes, Izzet; Acunas, Bulent

    2010-01-01

    Purpose: The aim of our study is to demonstrate the feasibility of body diffusion weighted (DW) MR imaging in the evaluation of pancreatic islet cell tumors (ICTs) and to define apparent diffusion coefficient (ADC) values for these tumors. Materials and methods: 12 normal volunteers and 12 patients with histopathologically proven pancreatic ICT by surgery were included in the study. DW MR images were obtained by a body-phased array coil using a multisection single-shot echo planar sequence on the axial plane without breath holding. In addition, the routine abdominal imaging protocol for pancreas was applied in the patient group. We measured the ADC value within the normal pancreas in control group, pancreatic ICT, and surrounding pancreas parenchyma. Mann-Whitney U-test has been used to compare ADC values between tumoral tissues and normal pancreatic tissues of the volunteers. Wilcoxon Signed Ranks Test was preferred to compare ADC values between tumoral tissues and surrounding pancreatic parenchyma of the patients. Results: In 11 patients out of 12, conventional MR sequences were able to demonstrate ICTs successfully. In 1 patient an indistinct suspicious lesion was noted at the pancreatic tail. DW sequence was able to demonstrate the lesions in all of the 12 patients. On the DW images, all ICTs demonstrated high signal intensity relative to the surrounding pancreatic parenchyma. The mean and standard deviations of the ADC values (x10 -3 mm 2 /s) were as follows: ICT (n = 12), 1.51 ± 0.35 (0.91-2.11), surrounding parenchyma (n = 11) 0.76 ± 0.15 (0.51-1.01) and normal pancreas in normal volunteers (n = 12), 0.80 ± 0.06 (0.72-0.90). ADC values of the ICT were significantly higher compared with those of surrounding parenchyma (p < 0.01) and normal pancreas (p < 0.001). Conclusion: DW MR imaging does not appear to provide significant contribution to routine MR imaging protocol in the evaluation of pancreatic islet cell tumors. But it can be added to MR imaging

  16. Diffusion weighted MR imaging of pancreatic islet cell tumors

    Energy Technology Data Exchange (ETDEWEB)

    Bakir, Baris [Department of Radiology, Istanbul University, Istanbul Medical School, Capa 34390, Istanbul (Turkey)], E-mail: drbarisbakir@yahoo.com; Salmaslioglu, Artur; Poyanli, Arzu; Rozanes, Izzet; Acunas, Bulent [Department of Radiology, Istanbul University, Istanbul Medical School, Capa 34390, Istanbul (Turkey)

    2010-04-15

    Purpose: The aim of our study is to demonstrate the feasibility of body diffusion weighted (DW) MR imaging in the evaluation of pancreatic islet cell tumors (ICTs) and to define apparent diffusion coefficient (ADC) values for these tumors. Materials and methods: 12 normal volunteers and 12 patients with histopathologically proven pancreatic ICT by surgery were included in the study. DW MR images were obtained by a body-phased array coil using a multisection single-shot echo planar sequence on the axial plane without breath holding. In addition, the routine abdominal imaging protocol for pancreas was applied in the patient group. We measured the ADC value within the normal pancreas in control group, pancreatic ICT, and surrounding pancreas parenchyma. Mann-Whitney U-test has been used to compare ADC values between tumoral tissues and normal pancreatic tissues of the volunteers. Wilcoxon Signed Ranks Test was preferred to compare ADC values between tumoral tissues and surrounding pancreatic parenchyma of the patients. Results: In 11 patients out of 12, conventional MR sequences were able to demonstrate ICTs successfully. In 1 patient an indistinct suspicious lesion was noted at the pancreatic tail. DW sequence was able to demonstrate the lesions in all of the 12 patients. On the DW images, all ICTs demonstrated high signal intensity relative to the surrounding pancreatic parenchyma. The mean and standard deviations of the ADC values (x10{sup -3} mm{sup 2}/s) were as follows: ICT (n = 12), 1.51 {+-} 0.35 (0.91-2.11), surrounding parenchyma (n = 11) 0.76 {+-} 0.15 (0.51-1.01) and normal pancreas in normal volunteers (n = 12), 0.80 {+-} 0.06 (0.72-0.90). ADC values of the ICT were significantly higher compared with those of surrounding parenchyma (p < 0.01) and normal pancreas (p < 0.001). Conclusion: DW MR imaging does not appear to provide significant contribution to routine MR imaging protocol in the evaluation of pancreatic islet cell tumors. But it can be added to

  17. Non-contrast-enhanced MR angiography in critical limb ischemia: performance of quiescent-interval single-shot (QISS) and TSE-based subtraction techniques

    International Nuclear Information System (INIS)

    Altaha, Mustafa A.; Jaskolka, Jeffrey D.; Tan, Kongteng; Menezes, Ravi J.; Rick, Manuela; Schmitt, Peter; Wintersperger, Bernd J.

    2017-01-01

    The aim of this study was to evaluate diagnostic performance of non-contrast-enhanced 2D quiescent-interval single-shot (QISS) and 3D turbo spin-echo (TSE)-based subtraction magnetic resonance angiography (MRA) in the assessment of peripheral arteries in patients with critical limb ischemia (CLI). Nineteen consecutive patients (74 % male, 72.8 ± 9.9 years) with CLI underwent 2D QISS and 3D TSE-based subtraction MRA at 1.5 T. Axial-overlapping QISS MRA (3 mm/2 mm; 1 x 1 mm 2 ) covered from the toes to the aortic bifurcation while coronal 3D TSE-based subtraction MRA (1.3 x 1.2 x 1.3 mm 3 ) was restricted to the calf only. MRA data sets (two readers) were evaluated for stenosis (≥50 %) and image quality. Results were compared with digital subtraction angiography (DSA). Two hundred and sixty-seven (267) segments were available for MRA-DSA comparison, with a prevalence of stenosis ≥50 % of 41.9 %. QISS MRA was rated as good to excellent in 79.5-96.0 % of segments without any nondiagnostic segments; 89.8-96.1 % of segments in 3D TSE-based subtraction MRA were rated as nondiagnostic or poor. QISS MRA sensitivities and specificities (segmental) were 92 % and 95 %, respectively, for reader one and 81-97 % for reader two. Due to poor image quality of 3D TSE-based subtraction MRA, diagnostic performance measures were not calculated. QISS MRA demonstrates excellent diagnostic performance and higher robustness than 3D TSE-based subtraction MRA in the challenging patient population with CLI. (orig.)

  18. Non-contrast-enhanced MR angiography in critical limb ischemia: performance of quiescent-interval single-shot (QISS) and TSE-based subtraction techniques

    Energy Technology Data Exchange (ETDEWEB)

    Altaha, Mustafa A. [University Health Network, Department of Medical Imaging, Peter Munk Cardiac Centre, Toronto, Ontario (Canada); Jaskolka, Jeffrey D.; Tan, Kongteng; Menezes, Ravi J. [University Health Network, Department of Medical Imaging, Peter Munk Cardiac Centre, Toronto, Ontario (Canada); University of Toronto, Department of Medical Imaging, Toronto, Ontario (Canada); Rick, Manuela; Schmitt, Peter [Siemens Healthcare, Erlangen (Germany); Wintersperger, Bernd J. [University Health Network, Department of Medical Imaging, Peter Munk Cardiac Centre, Toronto, Ontario (Canada); University of Toronto, Department of Medical Imaging, Toronto, Ontario (Canada); Toronto General Hospital, Department of Medical Imaging, Toronto, Ontario (Canada)

    2017-03-15

    The aim of this study was to evaluate diagnostic performance of non-contrast-enhanced 2D quiescent-interval single-shot (QISS) and 3D turbo spin-echo (TSE)-based subtraction magnetic resonance angiography (MRA) in the assessment of peripheral arteries in patients with critical limb ischemia (CLI). Nineteen consecutive patients (74 % male, 72.8 ± 9.9 years) with CLI underwent 2D QISS and 3D TSE-based subtraction MRA at 1.5 T. Axial-overlapping QISS MRA (3 mm/2 mm; 1 x 1 mm{sup 2}) covered from the toes to the aortic bifurcation while coronal 3D TSE-based subtraction MRA (1.3 x 1.2 x 1.3 mm{sup 3}) was restricted to the calf only. MRA data sets (two readers) were evaluated for stenosis (≥50 %) and image quality. Results were compared with digital subtraction angiography (DSA). Two hundred and sixty-seven (267) segments were available for MRA-DSA comparison, with a prevalence of stenosis ≥50 % of 41.9 %. QISS MRA was rated as good to excellent in 79.5-96.0 % of segments without any nondiagnostic segments; 89.8-96.1 % of segments in 3D TSE-based subtraction MRA were rated as nondiagnostic or poor. QISS MRA sensitivities and specificities (segmental) were 92 % and 95 %, respectively, for reader one and 81-97 % for reader two. Due to poor image quality of 3D TSE-based subtraction MRA, diagnostic performance measures were not calculated. QISS MRA demonstrates excellent diagnostic performance and higher robustness than 3D TSE-based subtraction MRA in the challenging patient population with CLI. (orig.)

  19. ECG-gated quiescent-interval single-shot MR angiography of the lower extremities: Initial experience at 3 T

    International Nuclear Information System (INIS)

    Knobloch, G.; Gielen, M.; Lauff, M.-T.; Romano, V.C.; Schmitt, P.; Rick, M.; Kröncke, T.J.; Huppertz, A.; Hamm, B.; Wagner, M.

    2014-01-01

    Aim: To evaluate the feasibility of unenhanced electrocardiography (ECG)-gated quiescent-interval single-shot magnetic resonance angiography (QISS-MRA) of the lower extremities at 3 T. Materials and methods: Twenty-five patients with known or suspected peripheral arterial disease underwent ECG-gated QISS-MRA and contrast-enhanced MRA (CE-MRA) at 3 T. Two independent readers performed a per-segment evaluation of the MRA datasets. Image quality was rated on a four-point scale (1 = excellent to 4 = non-diagnostic; presented as medians with interquartile range). Diagnostic performance of QISS-MRA was evaluated using CE-MRA as the reference standard. Results: QISS-MRA and CE-MRA of all patients were considered for analysis, resulting in 807 evaluated vessel segments for each MRA technique. Readers 1 and 2 rated image quality of QISS-MRA as diagnostic in 97.3% and 97% of the vessel segments, respectively. CE-MRA was rated diagnostic in all vessel segments. Image quality of the proximal vessel segments, including the infrarenal aorta, iliac arteries, and common femoral artery, was significantly lower on QISS-MRA compared to CE-MRA [image quality score across readers: 2 (1,3) versus 1 (1,1) p < 0.001]. In the more distal vessel segments, image quality of QISS-MRA was excellent and showed no significant difference compared to CE-MRA [image quality score across readers: 1 (1,1) versus 1 (1,1) p = 0.036]. Diagnostic performance of QISS-MRA was as follows (across readers): sensitivity: 87.5% (95% CI: 80.2–92.4%); specificity: 96.1% (95% CI: 93.6–97.6%); diagnostic accuracy: 94.9% (95% CI: 92.6–96.5%). Conclusions: QISS-MRA of the lower extremities is feasible at 3 T and provides high image quality, especially in the distal vessel segments

  20. ADC measurement of abdominal organs and lesions using parallel imaging technique.

    Science.gov (United States)

    Yoshikawa, Takeshi; Kawamitsu, Hideaki; Mitchell, Donald G; Ohno, Yoshiharu; Ku, Yonson; Seo, Yasushi; Fujii, Masahiko; Sugimura, Kazuro

    2006-12-01

    The purpose of our study was to assess the reliability and usefulness of parallel imaging for apparent diffusion coefficient (ADC) measurement of abdominal organs and lesions. Single-shot spin-echo echo-planar diffusion-weighted MRI (TE = 66, b = 0, 600 s/mm2) was performed in phantom and clinical studies. The b value was set to minimize the effects of perfusion in tissue and to maintain signal-to-noise ratio. Bottle phantoms were scanned with and without parallel imaging and with various parallel imaging factors and at various positions to evaluate the effects of parallel imaging on ADCs. In 200 consecutive clinical patients (122 men and 78 women: mean age, 61.9 years), ADCs were calculated for liver (four segments), spleen, pancreas (head, body, tail), gallbladder, renal parenchyma, and back muscle, and then compared to evaluate the reliability of clinical ADC measurements with parallel imaging. ADCs were also calculated for diffuse diseases and focal lesions (94 malignant and 93 benign) of abdominal organs to evaluate the clinical usefulness of ADC. Location-dependent changes in water ADCs were minimal with parallel imaging factors first of 3, then of 4, and were small except for measurements at the image periphery. Acetone ADCs were saturated at 4.00 x 10(-3) mm2/s. Degraded image quality prevented ADC measurement of the left hepatic lobe and pancreas in 7-18 patients. There was no significant difference among ADCs of four liver segments (1.50 +/- 0.24 [SD] x 10(-3) mm2/s - 1.56 +/- 0.31 x 10(-3) mm2/s) and between ADCs of the right and left kidneys (2.65 +/- 0.30 x 10(-3) mm2/s, 2.59 +/- 0.33 x 10(-3) mm2/s). ADC of the pancreas tail (1.65 +/- 0.37 x 10(-3) mm2/s) was significantly lower than those of the head (1.81 +/- 0.40 x 10(-3) mm2/s) and body (1.81 +/- 0.41 x 10(-3) mm2/s) (p parallel imaging appear to be reliable and useful, and the effect of parallel imaging on calculated values is considered to be minimal.

  1. Symptomatic hepatic cyst in a child: treatment with single-shot injection of tetracycline hydrochloride

    International Nuclear Information System (INIS)

    Fabrizzi, Giancarlo; Lanza, Cecilia; Bolli, Valeria; Pieroni, Giovanni

    2009-01-01

    The prevalence of hepatic cysts is 0.1% to 0.5% based on autopsy studies, and 2.5% based on US examinations. Percutaneous therapies are a new alternative to surgery. They include simple percutaneous aspiration, catheter drainage alone, and catheter drainage with sclerotherapy. We present an 11-year-old boy admitted to hospital because of abdominal pain. A diagnosis of simple hepatic cyst was made, which was treated with aspiration and tetracycline hydrochloride solution (5%) injection into the cystic cavity. Complete regression was seen on US and MRI examination at 3 months, with total collapse and deflation of the cyst. The cyst regressed totally, leaving a hyperechoic linear scar on US examination at 1 year. On the basis of the clinical and imaging results obtained, percutaneous sclerotherapy of hepatic cysts can be recommended as the treatment of choice and as a valid alternative to laparoscopy in children. (orig.)

  2. Symptomatic hepatic cyst in a child: treatment with single-shot injection of tetracycline hydrochloride

    Energy Technology Data Exchange (ETDEWEB)

    Fabrizzi, Giancarlo; Lanza, Cecilia; Bolli, Valeria; Pieroni, Giovanni [Azienda Ospedaliero-Universitaria Ospedali Riuniti, Servizio di Radiologia Generale e Pediatrica, Ancona (Italy)

    2009-10-15

    The prevalence of hepatic cysts is 0.1% to 0.5% based on autopsy studies, and 2.5% based on US examinations. Percutaneous therapies are a new alternative to surgery. They include simple percutaneous aspiration, catheter drainage alone, and catheter drainage with sclerotherapy. We present an 11-year-old boy admitted to hospital because of abdominal pain. A diagnosis of simple hepatic cyst was made, which was treated with aspiration and tetracycline hydrochloride solution (5%) injection into the cystic cavity. Complete regression was seen on US and MRI examination at 3 months, with total collapse and deflation of the cyst. The cyst regressed totally, leaving a hyperechoic linear scar on US examination at 1 year. On the basis of the clinical and imaging results obtained, percutaneous sclerotherapy of hepatic cysts can be recommended as the treatment of choice and as a valid alternative to laparoscopy in children. (orig.)

  3. Tabletop single-shot extreme ultraviolet Fourier transform holography of an extended object.

    Science.gov (United States)

    Malm, Erik B; Monserud, Nils C; Brown, Christopher G; Wachulak, Przemyslaw W; Xu, Huiwen; Balakrishnan, Ganesh; Chao, Weilun; Anderson, Erik; Marconi, Mario C

    2013-04-22

    We demonstrate single and multi-shot Fourier transform holography with the use of a tabletop extreme ultraviolet laser. The reference wave was produced by a Fresnel zone plate with a central opening that allowed the incident beam to illuminate the sample directly. The high reference wave intensity allows for larger objects to be imaged compared to mask-based lensless Fourier transform holography techniques. We obtain a spatial resolution of 169 nm from a single laser pulse and a resolution of 128 nm from an accumulation of 20 laser pulses for an object ~11x11μm(2) in size. This experiment utilized a tabletop extreme ultraviolet laser that produces a highly coherent ~1.2 ns laser pulse at 46.9 nm wavelength.

  4. Ankle Block vs Single-Shot Popliteal Fossa Block as Primary Anesthesia for Forefoot Operative Procedures: Prospective, Randomized Comparison.

    Science.gov (United States)

    Schipper, Oliver N; Hunt, Kenneth J; Anderson, Robert B; Davis, W Hodges; Jones, Carroll P; Cohen, Bruce E

    2017-11-01

    Postoperative pain is often difficult to control with oral medications, requiring large doses of opioid analgesia. Regional anesthesia may be used for primary anesthesia, reducing the need for general anesthetic and postoperative pain medication requirements in the immediate postoperative period. The purpose of this study was to compare the analgesic effects of an ankle block (AB) to a single-shot popliteal fossa block (PFB) for patients undergoing orthopedic forefoot procedures. All patients having elective outpatient orthopedic forefoot procedures were invited to participate in the study. Patients were prospectively randomized to receive either an ultrasound-guided AB or PFB by a board-certified anesthesiologist prior to their procedure. Intraoperative conversion to general anesthesia and postanesthesia care unit (PACU) opioid requirements were recorded. Postoperative pain was assessed using the visual analog scale (VAS) at regular time intervals until 8 am on postoperative day (POD) 2. Patients rated the effectiveness of the block on a 1 to 5 scale, with 5 being very effective. A total of 167 patients participated in the study with 88 patients (53%) receiving an AB and 79 (47%) receiving a single-shot PFB. There was no significant difference in the rate of conversion to general anesthesia between the 2 groups (13.6% [12/88] AB vs 12.7% [10/79] PFB). PACU morphine requirements and doses were significantly reduced in the PFB group ( P = .004) when compared to the AB group. The VAS was also significantly lower for the PFB patients at 10 pm on POD 0 (4.6 vs 1.6, P PFB 10.1%, P = .51) and there were no significant differences in residual sensory paresthesias (AB 2.3% [2/88] vs PFB 5.1% [4/79], P = .29), motor loss (0% vs 0%), or block site pain and/or erythema (AB 6.9% [6/88] vs PFB 5.1% [4/79], P = .44). The analgesic effect of the PFB lasted significantly longer when compared to the ankle block (AB 14.5 hours vs PFB 20.9 hours, P PFB 4.82/5, P = .68). Regional

  5. Flexible Low-power SiGe HBT Amplifier Circuits for Fast Single-shot Spin Readout

    Science.gov (United States)

    England, Troy; Lilly, Michael; Curry, Matthew; Carr, Stephen; Carroll, Malcolm

    Fast, low-power quantum state readout is one of many challenges facing quantum information processing. Single electron transistors (SETs) are potentially fast, sensitive detectors for performing spin readout of electrons bound to Si:P donors. From a circuit perspective, however, their output impedance and nonlinear conductance are ill suited to drive the parasitic capacitance of coaxial conductors used in cryogenic environments, necessitating a cryogenic amplification stage. We will introduce two new amplifier topologies that provide excellent gain versus power tradeoffs using silicon-germanium (SiGe) heterojunction bipolar transistors (HBTs). The AC HBT allows in-situ adjustment of power dissipation during an experiment and can provide gain in the millikelvin temperature regime while dissipating less than 500 nW. The AC Current Amplifier maximizes gain at nearly 800 A/A. We will also show results of using these amplifiers with SETs at 4 K. This work was performed, in part, at the Center for Integrated Nanotechnologies, a U.S. DOE Office of Basic Energy Sciences user facility. Sandia National Laboratories is a multi-program laboratory operated by Sandia Corporation, a Lockheed-Martin Company, for the U. S. Department of Energy under Contract No. DE-AC04-94AL85000. Flexible Low-power SiGe HBT Amplifier Circuits for Fast Single-shot Spin Readout.

  6. Real-Time, Single-Shot Temporal Measurements of Short Electron Bunches, Terahertz CSR and FEL Radiation

    CERN Document Server

    Berden, G; Van der Meer, A F G

    2005-01-01

    Electro-optic detection of the Coulomb field of electron bunches is a promising technique for single-shot measurements of the bunch length and shape in the sub-picosecond time domain. This technique has been applied to the measurement of 50 MeV electron bunches in the FELIX free electron laser, showing the longitudinal profile of single bunches of around 650 fs FWHM [Phys. Rev. Lett. 93, 114802 (2004)]. The method is non-destructive and real-time, and therefore ideal for online monitoring of the longitudinal shape of single electron bunches. At FELIX we have used it for real-time optimization of sub-picosecond electron bunches. Electro-optic detection has also been used to measure the electric field profiles of far-infrared (or terahertz) optical pulses generated by the relativistic electrons. We have characterised the far-infrared output of the free electron laser, and more recently, we have measured the temporal profile of terahertz optical pulses generated at one of the bending magnets.

  7. Fast and robust automatic calibration for single-shot dual-wavelength digital holography based on speckle displacements.

    Science.gov (United States)

    Khodadad, Davood; Bergström, Per; Hällstig, Emil; Sjödahl, Mikael

    2015-06-01

    The objective of this paper is to describe a fast and robust automatic single-shot dual-wavelength holographic calibration method that can be used for online shape measurement applications. We present a model of the correction in two terms for each lobe, one to compensate the systematic errors caused by off-axis angles and the other for the curvature of the reference waves, respectively. Each hologram is calibrated independently without a need for an iterative procedure or information of the experimental set-up. The calibration parameters are extracted directly from speckle displacements between different reconstruction planes. The parameters can be defined as any fraction of a pixel to avoid the effect of quantization. Using the speckle displacements, problems associated with phase wrapping is avoided. The procedure is shown to give a shape accuracy of 34 μm using a synthetic wavelength of 1.1 mm for a measurement on a cylindrical test object with a trace over a field of view of 18  mm×18  mm.

  8. Silicon-Vacancy Spin Qubit in Diamond: A Quantum Memory Exceeding 10 ms with Single-Shot State Readout

    Science.gov (United States)

    Sukachev, D. D.; Sipahigil, A.; Nguyen, C. T.; Bhaskar, M. K.; Evans, R. E.; Jelezko, F.; Lukin, M. D.

    2017-12-01

    The negatively charged silicon-vacancy (SiV- ) color center in diamond has recently emerged as a promising system for quantum photonics. Its symmetry-protected optical transitions enable the creation of indistinguishable emitter arrays and deterministic coupling to nanophotonic devices. Despite this, the longest coherence time associated with its electronic spin achieved to date (˜250 ns ) has been limited by coupling to acoustic phonons. We demonstrate coherent control and suppression of phonon-induced dephasing of the SiV- electronic spin coherence by 5 orders of magnitude by operating at temperatures below 500 mK. By aligning the magnetic field along the SiV- symmetry axis, we demonstrate spin-conserving optical transitions and single-shot readout of the SiV- spin with 89% fidelity. Coherent control of the SiV- spin with microwave fields is used to demonstrate a spin coherence time T2 of 13 ms and a spin relaxation time T1 exceeding 1 s at 100 mK. These results establish the SiV- as a promising solid-state candidate for the realization of quantum networks.

  9. Single-shot T1 mapping of the corpus callosum: A rapid characterization of fiber bundle anatomy

    Directory of Open Access Journals (Sweden)

    Sabine eHofer

    2015-05-01

    Full Text Available Using diffusion-tensor MRI and fiber tractography the topographic organization of the corpus callosum (CC has been described to comprise 5 segments with fibers projecting into prefrontal (I, premotor and supplementary motor (II, primary motor (III, and primary sensory areas (IV, as well as into parietal, temporal, and occipital cortical areas (V. In order to more rapidly characterize the underlying anatomy of these segments, this study used a novel single-shot T1 mapping method to quantitatively determine T1 relaxation times in the human CC. A region-of-interest analysis revealed a tendency for the lowest T1 relaxation times in the genu and the highest T1 relaxation times in the somatomotor region of the CC. This observation separates regions dominated by myelinated fibers with large diameters (somatomotor area from densely packed smaller axonal bundles (genu with less myelin. The results indicate that characteristic T1 relaxation times in callosal profiles provide an additional means to monitor differences in fiber anatomy, fiber density, and gray matter in respective neocortical areas. In conclusion, rapid T1 mapping allows for a characterization of the axonal architecture in an individual CC in less than 10 s. The approach emerges as a valuable means for studying neocortical brain anatomy with possible implications for the diagnosis of neurodegenerative processes.

  10. Near field flow characteristics of the Bjork-Shiley Monostrut valve in a modified single shot valve chamber.

    Science.gov (United States)

    Manning, Keefe B; Przybysz, T Michael; Fontaine, Arnold A; Tarbell, John M; Deutsch, Steven

    2005-01-01

    In certain mechanical heart valves, cavitation has been shown to develop during closure and rebound, leading to valve damage, blood damage, and strokes. Whereas it is uncertain what causes mechanical heart valve related strokes, some evidence suggests that stable bubbles may be the culprits. Previous work has indicated that vortex cavitation may contribute to stable bubble growth. Therefore, in an effort to understand the vortex cavitation, laser Doppler velocimetry data are collected in a plane parallel to and 3 mm away from the major orifice during closure and rebound of a Bjork-Shiley Monostrut mechanical heart valve. A modified single shot chamber is used that incorporates a more realistic near valve geometry than those used in previous studies. The results show the formation of a vortex during closure, which intensifies during rebound and dissipates during the final closing cycle. A regurgitant jet with mean velocities up to 3 m/s through the clearance gap of the valve provides energy to the vortex. During the final closing cycle, the vortex breaks up into asymmetrical, small scale flow patterns. This study provides further evidence that stable bubble formation may stem from the intense vortex cavitation occurring during valve closure and rebound.

  11. Poloxamer 407-chitosan grafted thermoresponsive hydrogels achieve synchronous and sustained release of antigen and adjuvant from single-shot vaccines.

    Science.gov (United States)

    Bobbala, Sharan; Gibson, Blake; Gamble, Allan B; McDowell, Arlene; Hook, Sarah

    2018-03-02

    Sustained release vaccine delivery systems may enhance the immunogenicity of subunit vaccines and reduce the need for multiple vaccinations. The aim of this study was to develop a thermoresponsive hydrogel using poloxamer 407-chitosan (CP) grafted copolymer as a delivery system for single-shot sustained release vaccines. The CP copolymer was synthesized using 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide (EDC) and N-hydroxysuccinimide (NHS) chemistry. The CP copolymer was a free flowing solution at ambient temperature and transformed rapidly into a gel at body temperature. The hydrogels were loaded with vaccine antigen and adjuvants or the vaccine components were encapsulated in poly (lactic-co-glycolic acid) nanoparticles (PLGA-NP) in order to ensure synchronous release. The CP hydrogels were stable for up to 18 days in vitro. Release of both nanoparticles and the individual components was complete, with release of the individual components being modulated by incorporation into nanoparticles. In vivo, a single dose of CP hydrogel vaccine induced strong, long lasting, cellular and humoral responses that could protect against the development of tumors in a murine melanoma model. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  12. Imaging and assessment of diffusion coefficients by magnetic resonance

    International Nuclear Information System (INIS)

    Tintera, J.; Dezortova, M.; Hajek, M.; Fitzek, C.

    1999-01-01

    The problem of assessment of molecular diffusion by magnetic resonance is highlighted and some typical applications of diffusion imaging in the diagnosis, e.g., of cerebral ischemia, changes in patients with phenylketonuria or multiple sclerosis are discussed. The images were obtained by using diffusion weighted spin echo Echo-Planar Imaging sequence with subsequent correction of the geometrical distortion of the images and calculation of the Apparent Diffusion Coefficient map

  13. Single-shot measurements of low emittance beams from laser-plasma accelerators comparing two triggered injection methods

    Science.gov (United States)

    van Tilborg, Jeroen

    2017-10-01

    The success of laser plasma accelerator (LPA) based applications, such as a compact x-ray free electron laser (FEL), relies on the ability to produce electron beams with excellent 6D brightness, where brightness is defined as the ratio of charge to the product of the three normalized emittances. As such, parametric studies of the emittance of LPA generated electron beams are essential. Profiting from a stable and tunable LPA setup, combined with a carefully designed single-shot energy-dispersed emittance diagnostic, we present a direct comparison of charge dependent emittance measurements of electron beams generated by two different injection mechanisms: ionization injection and shock-induced density down-ramp injection. Both injection mechanisms have gained in popularity in recent years due to their demonstrated stable LPA performance. For the down-ramp injection configuration, normalized emittances a factor of two lower were recorded: less than 1 micron at spectral charge densities up to 2 pC/MeV. For both injection mechanisms, a contributing correlation of space charge to the emittance was identified. This measurement technique in general, and these results specifically, are critical to the evaluation of LPA injection methods and development of high-quality LPA beam lines worldwide. This work is supported by the U.S. DOE under Contract No. DE-AC02-05CH11231, by the U.S. DOE NNSA, DNN R&D (NA22), by the National Science Foundation under Grant No. PHY-1415596, and by the Gordon and Betty Moore Foundation under Grant ID GBMF4898.

  14. Feasibility study of a single-shot 3D electron bunch shape monitor with an electro-optic sampling technique

    Directory of Open Access Journals (Sweden)

    Yuichi Okayasu

    2013-05-01

    Full Text Available We developed a three-dimensional electron bunch charge distribution (3D-BCD monitor with single-shot detection, and a spectral decoding based electro-optic (EO sampling technique for a nondestructive monitor enables real-time reconstruction of the three-dimensional distribution of a bunch charge. We realized three goals by simultaneously probing a number of Pockels EO crystals that surround the electron beam axis with hollow and radial polarized laser pulses. First, we performed a feasibility test as a simple case of a 3D-BCD monitor probing two ZnTe crystals as EO detectors installed on the opposite angle to the electron beam axis and confirmed that we simultaneously obtained both EO signals. Since the adopted hollow probe laser pulse is not only radially polarized but also temporally shifted azimuthally, some disorders in the radial polarization distribution of such a laser pulse were numerically analyzed with a plane-wave expansion method. Based on the above investigations, the 3D-BCD monitor is feasible both in experimental and numerical estimations. Furthermore, we previously developed a femtosecond response organic crystal as a Pockels EO detector and a broadband probe laser (≥350  nm in FWHM; the 3D-BCD monitor realizes 30- to 40-fs (FWHM temporal resolution. Eventually, the monitor is expected to be equipped in such advanced accelerators as XFEL to measure and adjust the electron bunch charge distribution in real time. The 3D-BCD measurement works as a critical tool to provide feedback to seeded FELs.

  15. Magnetic resonance advection imaging of cerebrovascular pulse dynamics.

    Science.gov (United States)

    Voss, Henning U; Dyke, Jonathan P; Tabelow, Karsten; Schiff, Nicholas D; Ballon, Douglas J

    2017-04-01

    We analyze the pulsatile signal component of dynamic echo planar imaging data from the brain by modeling the dependence between local temporal and spatial signal variability. The resulting magnetic resonance advection imaging maps depict the location of major arteries. Color direction maps allow for visualization of the direction of blood vessels. The potential significance of magnetic resonance advection imaging maps is demonstrated on a functional magnetic resonance imaging data set of 19 healthy subjects. A comparison with the here introduced pulse coherence maps, in which the echo planar imaging signal is correlated with a cardiac pulse signal, shows that the magnetic resonance advection imaging approach results in a better spatial definition without the need for a pulse reference. In addition, it is shown that magnetic resonance advection imaging velocities can be estimates of pulse wave velocities if certain requirements are met, which are specified. Although for this application magnetic resonance advection imaging velocities are not quantitative estimates of pulse wave velocities, they clearly depict local pulsatile dynamics. Magnetic resonance advection imaging can be applied to existing dynamic echo planar imaging data sets with sufficient spatiotemporal resolution. It is discussed whether magnetic resonance advection imaging might have the potential to evolve into a biomarker for the health of the cerebrovascular system.

  16. Diffusion-weighted imaging in the evaluation of watershed hypoxic-ischemic brain injury in pediatric patients

    Energy Technology Data Exchange (ETDEWEB)

    Liu, A.Y.; Zimmerman, R.A.; Haselgrove, J.C.; Bilaniuk, L.T.; Hunter, J.V. [Hospital of the Univ. of Pennsylvania (HUP), Philadelphia (United States). Dept. of Radiology

    2001-11-01

    The purpose of our study was to determine the usefulness of echo-planar diffusion-weighted imaging (EPDI) in the evaluation of watershed hypoxic-ischemic brain injury in pediatric patients. Eighteen patients ranging in age from 3 weeks to 12 years were evaluated for evidence of ischemic/infarction changes on conventional MR and EPDI. Included in the study group were five patients with sickle cell disease, four with congenital heart disease, four with hypotensive episodes with various etiologies, three with sepsis, and two with encephalitis or meningitis. Patients were examined 2 h to 6 days after the initial insult, with follow-up studies in four patients at 1 to 62 days after the initial examination. After conventional MR imaging (T1, FSE T2, and FLAIR), diffusion-weighted MR imaging was performed using high-speed, single-shot EP techniques with TR 6000, TE 144, matrix 96 x 128, FOV 23.3 x 31 and five b values of 0, 160, 360, 640, and 1,000 s/mm{sup 2}. EPDI demonstrated abnormally increased signal in watershed ischemic/infarction zones in all initial cases. Apparent diffusion coefficients (ADC) were obtained in 59 lesions. When compared with radiographically normal (on EPDI) contralateral brain parenchyma, 45 demonstrated a relatively decreased ADC, while eight had normal ({+-} 10 %) and six had increased ADC. In four cases, signal abnormalities on EPDI were not seen or exceeded that seen with conventional MR imaging. In the remaining cases, signal abnormalities were obvious on EPDI and more subtle on conventional MR imaging. Follow-up studies demonstrated resolution of abnormal EPDI signal with persistent abnormalities on conventional imaging in some cases, while others revealed an increase in size or number of EPDI signal abnormalities, suggesting ongoing acute ischemic/infarctive changes. EPDI is a rapid, sensitive technique for detecting watershed ischemic/infarction changes in pediatric patients with hypoperfusion episodes, at times before such changes are

  17. Diffusion-weighted breast imaging at 3 T: Preliminary experience

    International Nuclear Information System (INIS)

    Nogueira, L.; Brandão, S.; Matos, E.; Nunes, R.G.; Ferreira, H.A.; Loureiro, J.; Ramos, I.

    2014-01-01

    Aim: To evaluate the performance of diffusion-weighted imaging (DWI) at 3 T for the detection and characterization of breast lesions. Materials and methods: Magnetic resonance imaging (MRI) of the breast, including DWI single-shot spin-echo echo planar images (SS-SE-EPI; eight b-values, 50–3000 s/mm 2 ), were acquired in women with a clinical indication for breast MRI. The exclusion criteria were as follows: (1) previous breast surgery, radiotherapy and/or chemotherapy within the prior 48 months (14 women); (2) only cystic lesions (one woman); (3) no detectable enhancing lesion at dynamic contrast-enhanced (DCE)-MRI (15 women); and (4) breast implants (four women). MRI results were corroborated by histopathology or imaging follow-up. Apparent diffusion coefficients (ADCs) were estimated for lesions and normal glandular tissue. Differences in the ADC between tissue types were evaluated and the sensitivity and specificity of the method calculated by receiver operating characteristics (ROC) curves. Results: The final cohort comprised 53 patients with 59 lesions. Histopathology was obtained for 58 lesions. One lesion was validated as benign on imaging follow-up. Mean ADCs of 1.99 ± 0.27 × 10 −3  mm 2 /s, 1.08 ± 0.25 × 10 −3  mm 2 /s, and 1.74 ± 0.35 × 10 −3  mm 2 /s were obtained for normal tissue, malignant, and benign lesions, respectively. Mean ADCs of malignancies were significantly lower than those of benign lesions (p < 0.001) and normal tissue (p < 0.0001). The sensitivity and specificity for stratifying lesions, considering an ADC threshold of 1.41 × 10 −3  mm 2 /s, were 94.3% and 87.5%, respectively; accuracy was 91.5%. Conclusion: DWI proved useful for the detection and characterization of breast lesions in the present sample. ADC values provide a high diagnostic performance for differentiation between benign and malignant lesions

  18. Isotropic resolution diffusion tensor imaging of lumbosacral and sciatic nerves using a phase-corrected diffusion-prepared 3D turbo spin echo.

    Science.gov (United States)

    Cervantes, Barbara; Van, Anh T; Weidlich, Dominik; Kooijman, Hendrick; Hock, Andreas; Rummeny, Ernst J; Gersing, Alexandra; Kirschke, Jan S; Karampinos, Dimitrios C

    2018-08-01

    To perform in vivo isotropic-resolution diffusion tensor imaging (DTI) of lumbosacral and sciatic nerves with a phase-navigated diffusion-prepared (DP) 3D turbo spin echo (TSE) acquisition and modified reconstruction incorporating intershot phase-error correction and to investigate the improvement on image quality and diffusion quantification with the proposed phase correction. Phase-navigated DP 3D TSE included magnitude stabilizers to minimize motion and eddy-current effects on the signal magnitude. Phase navigation of motion-induced phase errors was introduced before readout in 3D TSE. DTI of lower back nerves was performed in vivo using 3D TSE and single-shot echo planar imaging (ss-EPI) in 13 subjects. Diffusion data were phase-corrected per k z plane with respect to T 2 -weighted data. The effects of motion-induced phase errors on DTI quantification was assessed for 3D TSE and compared with ss-EPI. Non-phase-corrected 3D TSE resulted in artifacts in diffusion-weighted images and overestimated DTI parameters in the sciatic nerve (mean diffusivity [MD] = 2.06 ± 0.45). Phase correction of 3D TSE DTI data resulted in reductions in all DTI parameters (MD = 1.73 ± 0.26) of statistical significance (P ≤ 0.001) and in closer agreement with ss-EPI DTI parameters (MD = 1.62 ± 0.21). DP 3D TSE with phase correction allows distortion-free isotropic diffusion imaging of lower back nerves with robustness to motion-induced artifacts and DTI quantification errors. Magn Reson Med 80:609-618, 2018. © 2018 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. © 2018 The Authors Magnetic Resonance

  19. Radiation damage to amorphous carbon thin films irradiated by multiple 46.9 nm laser shots below the single-shot damage threshold

    Czech Academy of Sciences Publication Activity Database

    Juha, Libor; Hájková, Věra; Chalupský, Jaromír; Vorlíček, Vladimír; Ritucci, A.; Reale, A.; Zuppella, P.; Störmer, M.

    2009-01-01

    Roč. 105, č. 9 (2009), 093117/1-093117/3 ISSN 0021-8979 R&D Projects: GA AV ČR KAN300100702; GA MŠk LC510; GA MŠk(CZ) LC528; GA MŠk LA08024; GA AV ČR IAA400100701 Institutional research plan: CEZ:AV0Z10100523 Keywords : single-shot damage threshold * multiple-shot exposure damage * amorphous carbon * radiation erosion * capillary-discharge XUV laser Subject RIV: BH - Optics, Masers, Lasers Impact factor: 2.072, year: 2009

  20. Wavefront Analysis of Nonlinear Self-Amplified Spontaneous-Emission Free-Electron Laser Harmonics in the Single-Shot Regime

    Energy Technology Data Exchange (ETDEWEB)

    Bachelard, R.; Chubar, O.; Mercere, P.; Idir, M.; Couprie, M.E.; Lambert, G.; Zeitoun, Ph.; Kimura, H.; Ohashi, H.; Higashiya, A.; Yabashi, M.; Nagasono, M.; Hara, T. and Ishikawa, T.

    2011-06-08

    The single-shot spatial characteristics of the vacuum ultraviolet self-amplified spontaneous emission of a free electron laser (FEL) is measured at different stages of amplification up to saturation with a Hartmann wavefront sensor. We show that the fundamental radiation at 61.5 nm tends towards a single-mode behavior as getting closer to saturation. The measurements are found in good agreement with simulations and theory. A near diffraction limited wavefront was measured. The analysis of Fresnel diffraction through the Hartmann wavefront sensor hole array also provides some further insight for the evaluation of the FEL transverse coherence, of high importance for various applications.

  1. Ballistic Imaging in the Primary Breakup Region of Diesel Injector Sprays

    National Research Council Canada - National Science Library

    Linne, M. A; Parker, T. E

    2006-01-01

    ...) for single-shot imaging of the near-field primary breakup region of a diesel spray. Ballistic imaging is a non-intrusive optical measurement technique that produces line-of-sight integrated images...

  2. Evaluation of a multiple spin- and gradient-echo (SAGE) EPI acquisition with SENSE acceleration: applications for perfusion imaging in and outside the brain.

    Science.gov (United States)

    Skinner, Jack T; Robison, Ryan K; Elder, Christopher P; Newton, Allen T; Damon, Bruce M; Quarles, C Chad

    2014-12-01

    Perfusion-based changes in MR signal intensity can occur in response to the introduction of exogenous contrast agents and endogenous tissue properties (e.g. blood oxygenation). MR measurements aimed at capturing these changes often implement single-shot echo planar imaging (ssEPI). In recent years ssEPI readouts have been combined with parallel imaging (PI) to allow fast dynamic multi-slice imaging as well as the incorporation of multiple echoes. A multiple spin- and gradient-echo (SAGE) EPI acquisition has recently been developed to allow measurement of transverse relaxation rate (R2 and R2(*)) changes in dynamic susceptibility contrast (DSC)-MRI experiments in the brain. With SAGE EPI, the use of PI can influence image quality, temporal resolution, and achievable echo times. The effect of PI on dynamic SAGE measurements, however, has not been evaluated. In this work, a SAGE EPI acquisition utilizing SENSE PI and partial Fourier (PF) acceleration was developed and evaluated. Voxel-wise measures of R2 and R2(*) in healthy brain were compared using SAGE EPI and conventional non-EPI multiple echo acquisitions with varying SENSE and PF acceleration. A conservative SENSE factor of 2 with PF factor of 0.73 was found to provide accurate measures of R2 and R2(*) in white (WM) (rR2=[0.55-0.79], rR2*=[0.47-0.71]) and gray (GM) matter (rR2=[0.26-0.59], rR2*=[0.39-0.74]) across subjects. The combined use of SENSE and PF allowed the first dynamic SAGE EPI measurements in muscle, with a SENSE factor of 3 and PF factor of 0.6 providing reliable relaxation rate estimates when compared to multi-echo methods. Application of the optimized SAGE protocol in DSC-MRI of high-grade glioma patients provided T1 leakage-corrected estimates of CBV and CBF as well as mean vessel diameter (mVD) and simultaneous measures of DCE-MRI parameters K(trans) and ve. Likewise, application of SAGE in a muscle reperfusion model allowed dynamic measures of R2', a parameter that has been shown to correlate

  3. Angle-resolved spectral Fabry-Pérot interferometer for single-shot measurement of refractive index dispersion over a broadband spectrum

    Science.gov (United States)

    Dong, J. T.; Ji, F.; Xia, H. J.; Liu, Z. J.; Zhang, T. D.; Yang, L.

    2018-01-01

    An angle-resolved spectral Fabry-Pérot interferometer is reported for fast and accurate measurement of the refractive index dispersion of optical materials with parallel plate shape. The light sheet from the wavelength tunable laser is incident on the parallel plate with converging angles. The transmitted interference light for each angle is dispersed and captured by a 2D sensor, in which the rows and the columns are used to simultaneously record the intensities as a function of wavelength and incident angle, respectively. The interferogram, named angle-resolved spectral intensity distribution, is analyzed by fitting the phase information instead of finding the fringe peak locations that present periodic ambiguity. The refractive index dispersion and the physical thickness can be then retrieved from a single-shot interferogram within 18 s. Experimental results of an optical substrate standard indicate that the accuracy of the refractive index dispersion is less than 2.5  ×  10-5 and the relative uncertainty of the thickness is 6  ×  10-5 mm (3σ) due to the high stability and the single-shot measurement of the proposed system.

  4. Infrared-spectroscopic single-shot laser mapping ellipsometry: Proof of concept for fast investigations of structured surfaces and interactions in organic thin films

    Science.gov (United States)

    Furchner, Andreas; Kratz, Christoph; Gkogkou, Dimitra; Ketelsen, Helge; Hinrichs, Karsten

    2017-11-01

    We present a novel infrared-spectroscopic laser mapping ellipsometer based on a single-shot measurement concept. The ellipsometric set-up employs multiple analyzers and detectors to simultaneously measure the sample's optical response under different analyzer azimuths. An essential component is a broadly tunable quantum cascade laser (QCL) covering the important marker region of 1800-1540 cm-1. The ellipsometer allows for fast single-wavelength as well as spectroscopic studies with thin-film sensitivity at temporal resolutions of 60 ms per wavelength. We applied the single-shot mapping ellipsometer for the characterization of metal-island enhancement surfaces as well as of molecular interactions in organic thin films. In less than 3 min, a linescan with 1600 steps revealed profile and infrared-enhancement properties of a gradient gold-island film for sensing applications. Spectroscopic measurements were performed to probe the amide I band of thin films of poly(N-isopropylacrylamide) [PNIPAAm], a stimuli-responsive polymer for bioapplications. The QCL spectra agree well with conventional FT-IR ellipsometric results, showing different band components associated with hydrogen-bond interactions between polymer and adsorbed water. Multi-wavelength ellipsometric maps were used to analyze homogeneity and surface contaminations of the polymer films.

  5. Diffusion-weighted magnetic resonance imaging of femoral head osteonecrosis in two groups of patients: Legg-Perthes-Calve and Avascular necrosis.

    Science.gov (United States)

    Ozel, Betul Duran; Ozel, Deniz; Ozkan, Fuat; Halefoglu, Ahmet M

    2016-03-01

    The aim of this prospective study was to evaluate the value of diffusion-weighted magnetic resonance imaging (DW-MRI) in patients with osteonecrosis. Patients were divided into two subgroups as avascular necrosis (AVN) of femoral head for adult group and Legg-Calvé-Perthes (LCP) patients for children. Seventeen patients with femoral head AVN (mean age 42.3 years) and 17 patients with LCP (mean age 8.2 years) were included in this study. Diagnosis confirmed with clinical and other imaging procedures among the patients complaining hip pain. DW images were obtained using the single-shot echo planar sequence and had b values of 0, 500, 1000 s/mm(2). The apparent diffusion coefficient (ADC) values were measured from ADC maps in epiphysis of patients with AVN, both from metaphysis and epiphysis in patients with LCP, respectively. Mann-Whitney U test was used to compare ADC values. The mean ADC value of femoral heads (1.285 ± 0.204 × 10(-3) mm(2)/s) was increased in patients with AVN when compared to normal bone tissue (0.209 ± 0.214 × 10(-3) mm(2)/s) (p < 0.01). The mean ADC values (×10(-3) mm(2)/s) of both metaphysis (0.852 ± 0.293) and epiphysis (0.843 ± 0.332) were also increased in patients with LCP and differences were statistically significant (p < 0.01). As a result, osteonecrosis shows increased ADC values. But it is a controversial concept that DWI offers a valuable data to conventional MRI or not. However, as there are report states, there is a correlation between the stage of the disease with ADC values in the LCP disease. DWI is a fast, without-contrast administration technique and provides quantitative values additional to conventional MR techniques; we believe DWI may play an additional assistance to the diagnosis and treatment for LCP patients. Multicentric larger group studies may provide additional data to this issue.

  6. Apparent Diffusion Coefficient Value of Diffusion-Weighted Imaging for Hepatocellular Carcinoma: Correlation with the Histologic Differentiation and the Expression of Vascular Endothelial Growth Factor

    International Nuclear Information System (INIS)

    Heo, Suk Hee; Jeong, Yong Yeon; Kim, Jin Woong; Lim, Hyo Soon; Lee, Jae Hyuk; Koh, Yang Seok; Cho, Chol Kyoon; Kang, Heoung Keun; Shin, Sang Soo

    2010-01-01

    To evaluate whether the histopathological differentiation and the expression of vascular endothelial growth factor (VEGF) of hepatocellular carcinoma (HCC) do show correlation with the apparent diffusion coefficient (ADC) value on diffusion-weighted imaging (DWI). Twenty-seven HCCs from 27 patients who had undergone preoperative liver MRI (1.5T) and surgical resection were retrospectively reviewed. DWI was obtained with a single-shot, echo-planar imaging sequence in the axial plane (b values: 0 and 1,000 sec/mm 2 ). On DWIs, the ADC value of the HCCs was measured by one radiologist, who was kept 'blinded' to the histological findings. Histopathologically, the differentiation was classified into well (n = 9), moderate (n = 9) and poor (n = 9). The expression of VEGF was semiquantitatively graded as grade 0 (n = 8), grade 1 (n = 9) and grade 2 (n = 10). We analyzed whether the histopathological differentiation and the expression of VEGF of the HCC showed correlation with the ADC value on DWI. The mean ADC value of the poorly-differentiated HCCs (0.9 ± 0.13x 10 -3 mm 2 /s) was lower than those of the well-differentiated HCCs (1.2 ± 0.22x 10 -3 mm 2 /s) (p = 0.031) and moderately-differentiated HCCs (1.1 ± 0.01x10 -3 mm 2 /s) (p = 0.013). There was a significant correlation between the differentiation and the ADC value of the HCCs (r = -0.51, p = 0.012). The mean ADC of the HCCs with a VEGF expression grade of 0, 1 and 2 was 1.1 ± 0.17, 1.1 ± 0.21 and 1.1 ± 0.18x10 -3 mm 2 /s, respectively. The VEGF expression did not show correlation with the ADC value of the HCCs (r = 0.07, p = 0.74). The histopathological differentiation of HCC shows inverse correlation with the ADC value. Therefore, DWI with ADC measurement may be a valuable tool for noninvasively predicting the differentiation of HCC

  7. Single-shot characterization of enzymatic reaction constants Km and kcat by an acoustic-driven, bubble-based fast micromixer

    Science.gov (United States)

    Xie, Yuliang; Ahmed, Daniel; Lapsley, Michael Ian; Lin, Sz-Chin Steven; Nawaz, Ahmad Ahsan; Wang, Lin; Huang, Tony Jun

    2014-01-01

    In this work we present an acoustofluidic approach for rapid, single-shot characterization of enzymatic reaction constants Km and kcat. The acoustofluidic design involves a bubble anchored in a horseshoe structure which can be stimulated by a piezoelectric transducer to generate vortices in the fluid. The enzyme and substrate can thus be mixed rapidly, within 100 ms, by the vortices to yield the product. Enzymatic reaction constants Km and kcat can then be obtained from the reaction rate curves for different concentrations of substrate while holding the enzyme concentration constant. We studied the enzymatic reaction for β-galactosidase and its substrate (resorufin β-D-galactopyranoside) and found Km and kcat to be 333±130 =M and 64±8 s−1 respectively, which are in agreement with published data. Our approach is valuable for studying the kinetics of high-speed enzymatic reactions and other chemical reactions. PMID:22880882

  8. Observation of single artificial atom optical bi-stability and its application to single-shot readout in circuit quantum electrodynamics

    Science.gov (United States)

    Sun, Luyan; Ginossar, Eran; Guy, Mikhael; Reed, Matthew; Paik, Hanhee; Bishop, Lev S.; Sears, Adam; Petrenko, Andrei; Brecht, Teresa; Frunzio, Luigi; Girvin, Steven; Schoelkopf, Robert

    2012-02-01

    The high power transient behavior of superconducting qubit-cavity systems has recently been used to perform high fidelity readout of transmon qubits [1]. We show that in the steady state, the system exhibits a bi-stable behavior that can be observed on the single-shot level, with the cavity state switching stochastically between dim and bright states. The switching times are shown to be long compared to the cavity and qubit lifetimes. Some features of the bi-stability can be explained by mean field theory, while its switching dynamics is studied with large scale simulations. Understanding these dynamics will be crucial for studying the transient response, an essential aspect of the qubit readout. We will discuss progress on optimizing readout by shaping the measurement pulse. [4pt] [1] M. D. Reed, L. DiCarlo, B. R. Johnson, L. Sun, D. I. Schuster, L. Frunzio, and R. J. Schoelkopf, Phys. Rev. Lett. 105, 173601 (2010)

  9. Measurement of the X-ray Spectrum of a Free Electron Laser with a Wide-Range High-Resolution Single-Shot Spectrometer

    Directory of Open Access Journals (Sweden)

    Yuichi Inubushi

    2017-06-01

    Full Text Available We developed a single-shot X-ray spectrometer for wide-range high-resolution measurements of Self-Amplified Spontaneous Emission (SASE X-ray Free Electron Laser (XFEL pulses. The spectrometer consists of a multi-layer elliptical mirror for producing a large divergence of 22 mrad around 9070 eV and a silicon (553 analyzer crystal. We achieved a wide energy range of 55 eV with a fine spectral resolution of 80 meV, which enabled the observation of a whole SASE-XFEL spectrum with fully-resolved spike structures. We found that a SASE-XFEL pulse has around 60 longitudinal modes with a pulse duration of 7.7 ± 1.1 fs.

  10. Gas-induced susceptibility artefacts on diffusion-weighted MRI of the rectum at 1.5 T - Effect of applying a micro-enema to improve image quality.

    Science.gov (United States)

    van Griethuysen, Joost J M; Bus, Elyse M; Hauptmann, Michael; Lahaye, Max J; Maas, Monique; Ter Beek, Leon C; Beets, Geerard L; Bakers, Frans C H; Beets-Tan, Regina G H; Lambregts, Doenja M J

    2018-02-01

    Assess whether application of a micro-enema can reduce gas-induced susceptibility artefacts in Single-shot Echo Planar Imaging (EPI) Diffusion-weighted imaging of the rectum at 1.5 T. Retrospective analysis of n = 50 rectal cancer patients who each underwent multiple DWI-MRIs (1.5 T) from 2012 to 2016 as part of routine follow-up during a watch-and-wait approach after chemoradiotherapy. From March 2014 DWI-MRIs were routinely acquired after application of a preparatory micro-enema (Microlax ® ; 5 ml; self-administered shortly before acquisition); before March 2014 no bowel preparation was given. In total, 335 scans were scored by an experienced reader for the presence/severity of gas-artefacts (on b1000 DWI), ranging from 0 (no artefact) to 5 (severe artefact). A score ≥3 (moderate-severe) was considered a clinically relevant artefact. A random sample of 100 scans was re-assessed by a second independent reader to study inter-observer effects. Scores were compared between the scans performed without and with a preparatory micro-enema using univariable and multivariable logistic regression taking into account potential confounding factors (age/gender, acquisition parameters, MRI-hardware, rectoscopy prior to MRI). Clinically relevant gas-artefacts were seen in 24.3% (no micro-enema) vs. 3.7% (micro-enema), odds ratios were 0.118 in univariable and 0.230 in multivariable regression (P = 0.0005 and 0.0291). Mean severity score (±SD) was 1.19 ± 1.71 (no-enema) vs 0.32 ± 0.77 (micro-enema), odds ratios were 0.321 (P < 0.0001) and 0.489 (P = 0.0461) in uni- and multivariable regression, respectively. Inter-observer agreement was excellent (κ0.85). Use of a preparatory micro-enema shortly before rectal EPI-DWI examinations performed at 1.5 T MRI significantly reduces both the incidence and severity of gas-induced artefacts, compared to examinations performed without bowel preparation. Copyright © 2017 Elsevier B.V. All rights

  11. Label-free nanoscale characterization of red blood cell structure and dynamics using single-shot transport of intensity equation

    Science.gov (United States)

    Poola, Praveen Kumar; John, Renu

    2017-10-01

    We report the results of characterization of red blood cell (RBC) structure and its dynamics with nanometric sensitivity using transport of intensity equation microscopy (TIEM). Conventional transport of intensity technique requires three intensity images and hence is not suitable for studying real-time dynamics of live biological samples. However, assuming the sample to be homogeneous, phase retrieval using transport of intensity equation has been demonstrated with single defocused measurement with x-rays. We adopt this technique for quantitative phase light microscopy of homogenous cells like RBCs. The main merits of this technique are its simplicity, cost-effectiveness, and ease of implementation on a conventional microscope. The phase information can be easily merged with regular bright-field and fluorescence images to provide multidimensional (three-dimensional spatial and temporal) information without any extra complexity in the setup. The phase measurement from the TIEM has been characterized using polymeric microbeads and the noise stability of the system has been analyzed. We explore the structure and real-time dynamics of RBCs and the subdomain membrane fluctuations using this technique.

  12. Dynamic NMR cardiac imaging in a piglet

    Energy Technology Data Exchange (ETDEWEB)

    Doyle, M.; Rzedzian, R.; Mansfield, P. (Nottingham Univ. (UK). Dept. of Physics); Coupland, R.E. (Nottingham Univ. (UK). Queen' s Medical Centre)

    1983-12-01

    NMR echo-planar imaging (EPI) has been used in a real-time mode to visualise the thorax of a live piglet. Moving pictures are available on an immediate image display system which demonstrates dynamic cardiac function. Frame rates vary from one per cardiac cycle in a prospective stroboscopic mode with immediate visual output to a maximum of 10 frames per second yielding up to six looks in one piglet heart cycle, but using a visual playback mode. A completely new system has been used to obtain these images, features of which include a probe assembly with 22 cm access and an AP400 array processor for real-time data processing.

  13. Optimization of mass spectrometric parameters improve the identification performance of capillary zone electrophoresis for single-shot bottom-up proteomics analysis.

    Science.gov (United States)

    Zhang, Zhenbin; Dovichi, Norman J

    2018-02-25

    The effects of MS1 injection time, MS2 injection time, dynamic exclusion time, intensity threshold, and isolation width were investigated on the numbers of peptide and protein identifications for single-shot bottom-up proteomics analysis using CZE-MS/MS analysis of a Xenopus laevis tryptic digest. An electrokinetically pumped nanospray interface was used to couple a linear-polyacrylamide coated capillary to a Q Exactive HF mass spectrometer. A sensitive method that used a 1.4 Th isolation width, 60,000 MS2 resolution, 110 ms MS2 injection time, and a top 7 fragmentation produced the largest number of identifications when the CZE loading amount was less than 100 ng. A programmable autogain control method (pAGC) that used a 1.4 Th isolation width, 15,000 MS2 resolution, 110 ms MS2 injection time, and top 10 fragmentation produced the largest number of identifications for CZE loading amounts greater than 100 ng; 7218 unique peptides and 1653 protein groups were identified from 200 ng by using the pAGC method. The effect of mass spectrometer conditions on the performance of UPLC-MS/MS was also investigated. A fast method that used a 1.4 Th isolation width, 30,000 MS2 resolution, 45 ms MS2 injection time, and top 12 fragmentation produced the largest number of identifications for 200 ng UPLC loading amount (6025 unique peptides and 1501 protein groups). This is the first report where the identification number for CZE surpasses that of the UPLC at the 200 ng loading level. However, more peptides (11476) and protein groups (2378) were identified by using UPLC-MS/MS when the sample loading amount was increased to 2 μg with the fast method. To exploit the fast scan speed of the Q-Exactive HF mass spectrometer, higher sample loading amounts are required for single-shot bottom-up proteomics analysis using CZE-MS/MS. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Single shot spinal anesthesia with very low hyperbaric bupivacaine dose (3.75 mg) for hip fracture repair surgery in the elderly. A randomized, double blinded study.

    Science.gov (United States)

    Errando, C L; Peiró, C M; Gimeno, A; Soriano, J L

    2014-11-01

    Single shot spinal anesthesia is used worldwide for hip fracture repair surgery in the elderly. Arterial hypotension is a frequent adverse effect. We hypothesized that lowering local anesthetics dose could decrease the incidence of arterial hypotension, while maintaining quality of surgical anesthesia. In a randomized double blinded study, 66 patients over the age of 65 years, with hip fracture needing surgical repair, were assigned to B0.5 group 7.5mg hyperbaric bupivacaine 5mg/ml (control group), and B0.25 group 3.75mg hyperbaric bupivacaine 2.5mg/ml (study group). Sensory and motor block level, and hemodynamic parameters including blood presure, heart rate and vasopressor dose administration were registered, along with rescue anesthesia needs, the feasibility of surgery, its duration, and regression time of sensory anesthesia to T12. After exclusions, 61 patients were included in the final analysis. Arterial hypotension incidence was lower in the B0.25 group (at the 5, 10, and 15min determinations), and a lower amount of vasopressor drugs was needed (mean accumulated ephedrine dose 1.6mg vs. 8.7mg in the B0.5 group, p<0.002). Sensory block regression time to T12 was shorter in the B0.25 group, mean 78.6±23.6 (95% CI 51.7-110.2)min vs. 125.5±37.9 (95% CI 101.7-169.4)min in the B0.5 group, p=0.033. All but one patient in the B0.25 group were operated on under the anesthetic procedure first intended. No rescue anesthesia was needed. Lowering bupivacaine dose for single shot spinal anesthesia for hip fracture repair surgery in elderly patients was effective in decreasing the occurrence of arterial hypotension and vasopressor use, while intraoperative quality remained. Copyright © 2014 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Advanced Magnetic Resonance Imaging techniques to probe muscle structure and function

    Science.gov (United States)

    Malis, Vadim

    Structural and functional Magnetic Resonance Imaging (MRI) studies of skeletal muscle allow the elucidation of muscle physiology under normal and pathological conditions. Continuing on the efforts of the Muscle Imaging and Modeling laboratory, the focus of the thesis is to (i) extend and refine two challenging imaging modalities: structural imaging using Diffusion Tensor Imaging (DTI) and functional imaging based on Velocity Encoded Phase Contrast Imaging (VE-PC) and (ii) apply these methods to explore age related structure and functional differences of the gastrocnemius muscle. Diffusion Tensor Imaging allows the study of tissue microstructure as well as muscle fiber architecture. The images, based on an ultrafast single shot Echo Planar Imaging (EPI) sequence, suffer from geometric distortions and low signal to noise ratio. A processing pipeline was developed to correct for distortions and to improve image Signal to Noise Ratio (SNR). DTI acquired on a senior and young cohort of subjects were processed through the pipeline and differences in DTI derived indices and fiber architecture between the two cohorts were explored. The DTI indices indicated that at the microstructural level, fiber atrophy was accompanied with a reduction in fiber volume fraction. At the fiber architecture level, fiber length and pennation angles decreased with age that potentially contribute to the loss of muscle force with age. Velocity Encoded Phase Contrast imaging provides tissue (e.g. muscle) velocity at each voxel which allows the study of strain and Strain Rate (SR) under dynamic conditions. The focus of the thesis was to extract 2D strain rate tensor maps from the velocity images and apply the method to study age related differences. The tensor mapping can potentially provide unique information on the extracellular matrix and lateral transmission the role of these two elements has recently emerged as important determinants of force loss with age. In the cross sectional study on

  16. Single-shot characterization of enzymatic reaction constants Km and kcat by an acoustic-driven, bubble-based fast micromixer.

    Science.gov (United States)

    Xie, Yuliang; Ahmed, Daniel; Lapsley, Michael Ian; Lin, Sz-Chin Steven; Nawaz, Ahmad Ahsan; Wang, Lin; Huang, Tony Jun

    2012-09-04

    In this work we present an acoustofluidic approach for rapid, single-shot characterization of enzymatic reaction constants K(m) and k(cat). The acoustofluidic design involves a bubble anchored in a horseshoe structure which can be stimulated by a piezoelectric transducer to generate vortices in the fluid. The enzyme and substrate can thus be mixed rapidly, within 100 ms, by the vortices to yield the product. Enzymatic reaction constants K(m) and k(cat) can then be obtained from the reaction rate curves for different concentrations of substrate while holding the enzyme concentration constant. We studied the enzymatic reaction for β-galactosidase and its substrate (resorufin-β-D-galactopyranoside) and found K(m) and k(cat) to be 333 ± 130 μM and 64 ± 8 s(-1), respectively, which are in agreement with published data. Our approach is valuable for studying the kinetics of high-speed enzymatic reactions and other chemical reactions.

  17. Silicon-Vacancy Spin Qubit in Diamond: A Quantum Memory Exceeding 10 ms with Single-Shot State Readout.

    Science.gov (United States)

    Sukachev, D D; Sipahigil, A; Nguyen, C T; Bhaskar, M K; Evans, R E; Jelezko, F; Lukin, M D

    2017-12-01

    The negatively charged silicon-vacancy (SiV^{-}) color center in diamond has recently emerged as a promising system for quantum photonics. Its symmetry-protected optical transitions enable the creation of indistinguishable emitter arrays and deterministic coupling to nanophotonic devices. Despite this, the longest coherence time associated with its electronic spin achieved to date (∼250  ns) has been limited by coupling to acoustic phonons. We demonstrate coherent control and suppression of phonon-induced dephasing of the SiV^{-} electronic spin coherence by 5 orders of magnitude by operating at temperatures below 500 mK. By aligning the magnetic field along the SiV^{-} symmetry axis, we demonstrate spin-conserving optical transitions and single-shot readout of the SiV^{-} spin with 89% fidelity. Coherent control of the SiV^{-} spin with microwave fields is used to demonstrate a spin coherence time T_{2} of 13 ms and a spin relaxation time T_{1} exceeding 1 s at 100 mK. These results establish the SiV^{-} as a promising solid-state candidate for the realization of quantum networks.

  18. Development of Compton X-ray spectrometer for high energy resolution single-shot high-flux hard X-ray spectroscopy.

    Science.gov (United States)

    Kojima, Sadaoki; Ikenouchi, Takahito; Arikawa, Yasunobu; Sakata, Shohei; Zhang, Zhe; Abe, Yuki; Nakai, Mitsuo; Nishimura, Hiroaki; Shiraga, Hiroyuki; Ozaki, Tetsuo; Miyamoto, Shuji; Yamaguchi, Masashi; Takemoto, Akinori; Fujioka, Shinsuke; Azechi, Hiroshi

    2016-04-01

    Hard X-ray spectroscopy is an essential diagnostics used to understand physical processes that take place in high energy density plasmas produced by intense laser-plasma interactions. A bundle of hard X-ray detectors, of which the responses have different energy thresholds, is used as a conventional single-shot spectrometer for high-flux (>10(13) photons/shot) hard X-rays. However, high energy resolution (Δhv/hv spectrometer because its energy resolution is limited by energy differences between the response thresholds. Experimental demonstration of a Compton X-ray spectrometer has already been performed for obtaining higher energy resolution than that of DET spectrometers. In this paper, we describe design details of the Compton X-ray spectrometer, especially dependence of energy resolution and absolute response on photon-electron converter design and its background reduction scheme, and also its application to the laser-plasma interaction experiment. The developed spectrometer was used for spectroscopy of bremsstrahlung X-rays generated by intense laser-plasma interactions using a 200 μm thickness SiO2 converter. The X-ray spectrum obtained with the Compton X-ray spectrometer is consistent with that obtained with a DET X-ray spectrometer, furthermore higher certainly of a spectral intensity is obtained with the Compton X-ray spectrometer than that with the DET X-ray spectrometer in the photon energy range above 5 MeV.

  19. Highly Resolved Mg/Ca Depth Profiles of Planktic Foraminifer test Walls Using Single shot Measurements of fs-LA-ICPMS

    Science.gov (United States)

    Jochum, K. P.; Schiebel, R.; Stoll, B.; Weis, U.; Haug, G. H.

    2017-12-01

    Foraminifers are sensitive archives of changes in climate and marine environment. It has been shown that the Mg/Ca signal is a suitable proxy of seawater temperature, because the incorporation of Mg depends on ambient water temperature. In contrast to most former studies, where this ratio is determined by solution-based bulk analysis of 20 - 30 specimens, we have investigated Mg/Ca in single specimens and single chambers at high resolution. A new fs-200 nm-LA-ICPMS technique was developed for the µm-sized layered calcite shells. To generate depth profiles with a resolution of about 50 nm/shot, we chose a low fluence of about 0.3 Jcm-2 and performed single shot measurements of the double charged 44Ca++ and the single charged 25Mg+ ions together. Precision (RSD) of the Mg/Ca data is about 5 %. Calibration was performed with the carbonate reference material MACS-3 from the USGS. Our results for different species from the Arabian Sea and Caribbean Sea demonstrate that Mg/Ca of different chambers vary and indicate that the foraminifer individuals built their chambers in different water depths and/or experienced seasonal changes in seawater temperature caused, for example, by upwelling (cold) versus stratified (warm) conditions. Typically, the Mg/Ca ratios of the final two chambers of the planktic foraminifer Globorotalia menardii from a sediment core of the Arabian Sea differ by about 5 mmol/mol from earlier chambers (2 mmol/mol) corresponding to seawater temperatures of 28 °C and 18 °C, respectively. In addition, mass fractions of other elements like Sr, Mn, Fe, Ba, and U have been determined with fs-LA-ICPMS using fast line scans, and thus provide further insights in the ecology of foraminifers.

  20. Development of Compton X-ray spectrometer for high energy resolution single-shot high-flux hard X-ray spectroscopy

    International Nuclear Information System (INIS)

    Kojima, Sadaoki; Ikenouchi, Takahito; Arikawa, Yasunobu; Sakata, Shohei; Zhang, Zhe; Abe, Yuki; Nakai, Mitsuo; Nishimura, Hiroaki; Shiraga, Hiroyuki; Fujioka, Shinsuke; Azechi, Hiroshi; Ozaki, Tetsuo; Miyamoto, Shuji; Yamaguchi, Masashi; Takemoto, Akinori

    2016-01-01

    Hard X-ray spectroscopy is an essential diagnostics used to understand physical processes that take place in high energy density plasmas produced by intense laser-plasma interactions. A bundle of hard X-ray detectors, of which the responses have different energy thresholds, is used as a conventional single-shot spectrometer for high-flux (>10 13 photons/shot) hard X-rays. However, high energy resolution (Δhv/hv < 0.1) is not achievable with a differential energy threshold (DET) X-ray spectrometer because its energy resolution is limited by energy differences between the response thresholds. Experimental demonstration of a Compton X-ray spectrometer has already been performed for obtaining higher energy resolution than that of DET spectrometers. In this paper, we describe design details of the Compton X-ray spectrometer, especially dependence of energy resolution and absolute response on photon-electron converter design and its background reduction scheme, and also its application to the laser-plasma interaction experiment. The developed spectrometer was used for spectroscopy of bremsstrahlung X-rays generated by intense laser-plasma interactions using a 200 μm thickness SiO 2 converter. The X-ray spectrum obtained with the Compton X-ray spectrometer is consistent with that obtained with a DET X-ray spectrometer, furthermore higher certainly of a spectral intensity is obtained with the Compton X-ray spectrometer than that with the DET X-ray spectrometer in the photon energy range above 5 MeV.

  1. Non-chromatographic preparation of a bacterially produced single-shot modular virus-like particle capsomere vaccine for avian influenza.

    Science.gov (United States)

    Wibowo, Nani; Wu, Yang; Fan, Yuanyuan; Meers, Joanne; Lua, Linda H L; Middelberg, Anton P J

    2015-11-04

    Highly pathogenic avian influenza (HPAI) causes significant economic loss, reduced food security and poses an ongoing pandemic threat. Poultry vaccination significantly decreases these problems and recognizes that the health of humans, animals and ecosystems are connected. Low-cost manufacture of poultry vaccine matched quickly to the ever-changing circulating strain is needed for effective vaccination. Here, we re-engineered the process to manufacture bacterially synthesized modular capsomere comprising influenza M2e, previously shown to confer complete protection in challenged mice, for application in poultry. Modular capsomere was prepared using a simplified non-chromatographic salting-out precipitation method and its immunogenicity tested in vivo in poultry. Modular capsomere crudely purified by precipitation (pCapM2e) contained more contaminants than equivalent product purified by chromatography (cCapM2e). Unadjuvanted pCapM2e containing 80 EU of endotoxin per dose was inferior to highly purified and adjuvanted cCapM2e (2 EU per dose). However, addition of adjuvant to pCapM2e resulting in high immunogenicity after only a single dose of vaccination, yet without any local adverse reaction. This finding suggests a strong synergy between adjuvant, antigen and contaminants, and the possible existence of a "Goldilocks" level of contaminants, where high immunogenicity and low reactogenicity can be obtained in a single-shot vaccination. The simplified process offers potential cost and speed advantages to address the needs in influenza poultry vaccination in low-cost veterinary markets. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Fast method of NMR imaging based on trains of spin echoes

    International Nuclear Information System (INIS)

    Hennel, F.

    1993-01-01

    A theoretical introduction to Fourier NMR imaging and a discussion of fast methods are presented. Then an application of the method of echo-planar imaging (EPI) with spin echoes in a micro-imaging system is described together with introduced modifications of the sequence. A new technique for the measurement of flow profiles in liquids which results from a modification of x-pulsed EPI is presented. The development of new software for a NMR micro-imaging system is described, too. 51 refs, 29 refs

  3. Single-Shot-RARE for rapid 3D hyperpolarized metabolic ex vivo tissue imaging: RF-pulse design for semi-dense spectra

    DEFF Research Database (Denmark)

    Magnusson, P.O.; Jensen, Pernille Rose; Dyrby, Tim Bjørn

    MRS of hyperpolarized (HP) 13C-enriched compounds is a promising method for in vivo cancer diagnosis . Sentinel lymph node ex vivo tissue sample histology used in clinical routine for breast cancer metastasis diagnosis requires time consuming sample analysis. 3D-HP-MRSI can potentially speed up...

  4. Intra-Articular, Single-Shot Hylan G-F 20 Hyaluronic Acid Injection Compared with Corticosteroid in Knee Osteoarthritis: A Double-Blind, Randomized Controlled Trial.

    Science.gov (United States)

    Tammachote, Nattapol; Kanitnate, Supakit; Yakumpor, Thanasak; Panichkul, Phonthakorn

    2016-06-01

    The treatment of knee osteoarthritis with hyaluronic acid or corticosteroid injection has been widely used. The purpose of this study was to compare the efficacy of hyaluronic acid (hylan G-F 20) with triamcinolone acetonide as a single intra-articular injection for knee osteoarthritis. This study was a prospective, randomized, double-blind clinical trial. Participants with symptomatic knee osteoarthritis were recruited. They were randomized to receive a single-shot, intra-articular injection of either 6 mL of hylan G-F 20 or 6 mL of a solution comprising 1 mL of 40-mg triamcinolone acetonide and 5 mL of 1% lidocaine with epinephrine. The primary outcomes were knee pain severity, knee function, and range of motion at 6 months. Ninety-nine patients were assessed before injection and underwent a 6-month follow-up. Patients and evaluators were blinded. Multilevel regression models were used to estimate differences between the groups. At the 6-month follow-up, compared with patients who took hylan G-F 20, patients who took triamcinolone acetonide had similar improvement in knee pain, knee function, and range of motion. The difference in mean outcome scores between groups was, with regard to knee pain, a visual analog scale (VAS) score of 3 points (95% confidence interval [95% CI], -6 to 11 points); with regard to knee function, a modified Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score of 0 points (95% CI, -8 to 6 points); and, with regard to range of motion, flexion of -1° (95% CI, -5° to 2°) and extension of 0° (95% CI, -0.5° to 0.5°). However, patients who took triamcinolone acetonide had better pain improvement from 24 hours until 1 week after injection; the mean difference between groups with regard to the VAS score was 12 points (95% CI, 5 to 20 points; p = 0.002) at 24 hours and 9 points (95% CI, 1 to 15 points; p = 0.018) at 1 week. At 2 weeks after injection, patients who took triamcinolone acetonide also had better knee

  5. Diffusion-Weighted Imaging of the Head and Neck: Influence of Fat-Suppression Technique and Multishot 2D Navigated Interleaved Acquisitions.

    Science.gov (United States)

    Bae, Y J; Choi, B S; Jeong, H-K; Sunwoo, L; Jung, C; Kim, J H

    2018-01-01

    DWI of the head and neck can reveal valuable information, but the effects of fat suppression and multishot acquisition on image quality have not been thoroughly investigated. We aimed to comprehensively compare the quality of head and neck DWI at 3T using 2 fat-suppression techniques, STIR, and spectral presaturation with inversion recovery, which were used with both single- and multishot EPI. Sixty-five study participants underwent 3 DWI sequences of single-shot EPI-STIR, single-shot EPI-spectral presaturation with inversion recovery, and multishot EPI-spectral presaturation with inversion recovery of the head and neck. In multiple anatomic regions, 2 independent readers assessed 5-point visual scores for fat-suppression uniformity and image distortion, and 1 reader measured the contrast-to-noise ratio and ADC. The mean visual score for fat-suppression uniformity was higher in single-shot EPI-STIR than in other sequences (all regions except for the orbital region, P < .05). The mean visual score for image distortion was higher in multishot EPI-spectral presaturation with inversion recovery than in single-shot EPI sequences (all regions, P < .001). Contrast-to-noise ratio was mostly lower in single-shot EPI-STIR than in other sequences ( P < .001), and ADC was significantly higher in multishot EPI-spectral presaturation with inversion recovery than in single-shot EPI sequences ( P ≤ .001). Overall, multishot EPI-spectral presaturation with inversion recovery provided the best image quality, with relatively homogeneous fat suppression, less image distortion than single-shot EPI sequences, and higher contrast-to-noise ratio than single-shot EPI-STIR. The measured ADC values can be higher in multishot EPI-spectral presaturation with inversion recovery, which necessitates cautious application of the previously reported ADC values to clinical settings. © 2018 by American Journal of Neuroradiology.

  6. Interscalene brachial plexus block for open-shoulder surgery: a randomized, double-blind, placebo-controlled trial between single-shot anesthesia and patient-controlled catheter system.

    Science.gov (United States)

    Goebel, Sascha; Stehle, Jens; Schwemmer, Ulrich; Reppenhagen, Stephan; Rath, Beatrice; Gohlke, Frank

    2010-04-01

    Interscalene brachial plexus block (ISB) is widely used as an adjuvant regional pain therapy in patients undergoing major shoulder surgery and has proved its effectiveness on postoperative pain reduction and opioid-sparing effect. This single-center, prospective, double-blind, randomized and placebo-controlled study was to compare the effectiveness of a single-shot and a patient-controlled catheter insertion ISB system after major open-shoulder surgeries. Seventy patients were entered to receive an ISB and a patient-controlled interscalene catheter. The catheter was inserted under ultrasound guidance. Patients were then assigned to receive one of two different postoperative infusions, either 0.2% ropivacaine (catheter group) or normal saline solution (single-shot group) via a disposable patient-controlled infusion pump. The study variables were amount of rescue medication, pain at rest and during physiotherapy, patient satisfaction and incidence of unwanted side effects. The ropivacaine group revealed significantly less consumption of rescue medication within the first 24 h after surgery. Incidence of side effects did not differ between the two groups. Based on our results, we recommend the use of interscalene plexus block in combination with a patient-controlled catheter system under ultrasound guidance only for the first 24 h after major open-shoulder surgery.

  7. Myocardial first-pass perfusion imaging with hybrid-EPI: frequency-offsets and potential artefacts

    Directory of Open Access Journals (Sweden)

    Ferreira Pedro F

    2012-06-01

    Full Text Available Abstract Background First-pass myocardial perfusion is often imaged with a tailored hybrid centric interleaved echo-planar-imaging sequence, providing rapid image acquisition with good contrast enhancement. The centric interleaved phase-encode order minimises the effective time-of-echo but it is sensitive to frequency-offsets. This short article aims to show possible artefacts that might originate with this sequence, in the context of first-pass perfusion imaging, when frequency-offsets are present. Non-uniform magnitude modulation effects were also analysed. Methods Numerical and phantom simulations were used to illustrate the effects of frequency-offsets and non-uniform magnitude modulation with this sequence in a typical perfusion protocol. In vivo data was post-processed to analyse the h-EPI’s sensitivity to the frequency-offsets. Results The centric phase-order was shown to be highly sensitive to frequency-offsets due to its symmetrical phase slope. Resulting artefacts include blurring, and splitting of the image into two identical copies along the phase-encode direction. It was also shown that frequency-offsets can introduce signal loss and ghosting of the right ventricle signal into the myocardium. The in vivo results were confirmed by numerical and phantom simulations. Magnitude modulation effects were found to be small. Conclusions Imaging first-pass myocardial perfusion with an hybrid centric echo-planar-imaging sequence can be corrupted with ghosting and splitting of the image due to frequency-offsets.

  8. Clinical evaluation of pulmonary perfusion MRI using FAIR (flow-sensitive alternating inversion recovery)-HASTE (Half-Fourier Single-Shot TurboSE) method

    International Nuclear Information System (INIS)

    Togami, Izumi; Sasai, Nobuya; Tsunoda, Masatoshi; Sei, Tetsurou; Sato, Shuhei; Yabuki, Takayuki; Hiraki, Yoshio

    2002-01-01

    The FAIR-HASTE method is a kind of noninvasive perfusion MR imaging obtained without the use of contrast media. By subtracting a flow-insensitive image from a flow-sensitive image, contrast enhancement of inflowing blood achieved. In the present study, we applied pulmonary perfusion FAIR-HASTE sequence for 23 patients with various pulmonary diseases, and compared the findings with those by pulmonary perfusion scintigraphy and Gadolinium perfusion MRI. Pulmonary perfusion imaging with the FAIR-HASTE method was possible in all clinical cases, and the findings corresponded well to those obtained by perfusion MRI using contrast media or pulmonary scintigraphy. The FAIR-HASTE method is a promising method for the evaluation of pulmonary perfusion. (author)

  9. Functional magnetic resonance imaging of the heart and large vessels

    International Nuclear Information System (INIS)

    Coupland, R.E.; Mansfield, P.

    1987-01-01

    Imaging times using planar imaging techniques including projection reconstruction and two-dimensional Fourier transformation methods are comparatively long, typically 2-5 min: in consequence patient throughput is reduced. Problems also arise with regard to involuntary movements, e.g. of viscera, which degrade images. Gating procedures, especially in the heart, can to some extent overcome the problems of movements that would otherwise blur or degrade the image. Since 1976-1977 a new approach to the problem of imaging of moving organs has been developed. This allows the encoding and observing of all regions in a cross-sectional slice in a single experiment that lasts only a few tens of milliseconds. The technique is commonly referred to as echo planar imaging

  10. Dynamic NMR cardiac imaging in a piglet

    International Nuclear Information System (INIS)

    Doyle, M.; Rzedzian, R.; Mansfield, P.; Coupland, R.E.

    1983-01-01

    NMR echo-planar imaging (EPI) has been used in a real-time mode to visualise the thorax of a live piglet. Moving pictures are available on an immediate image display system which demonstrates dynamic cardiac function. Frame rates vary from one per cardiac cycle in a prospective stroboscopic mode with immediate visual output to a maximum of 10 frames per second yielding up to six looks in one piglet heart cycle, but using a visual playback mode. A completely new system has been used to obtain these images, features of which include a probe assembly with 22 cm access and an AP400 array processor for real-time data processing. (author)

  11. [Importance of diffusion weighted magnetic resonance imaging at differentiation of cholesteatoma and granulation tissue in patients with chronic suppurative otitis media].

    Science.gov (United States)

    Tuzcu, Göksel; Yardımcı, Aytül Hande; Turna, Önder; Göner, Reyyan Elif; Acıoğlu, Engin

    2015-01-01

    This study aims to report the significance of echo-planar diffusion-weighted imaging (EP-DWI) in preoperative magnetic resonance imaging of patients with surgically corrected cholesteatoma and granulation tissue according to DWI and apparent diffusion coefficient (ADC) values. Ninety-one patients (52 males, 39 females; mean age 40.7±15.8 years; range 3 to 77 years) who admitted to radiology clinic of our hospital between December 2009 and May 2011 with a pre-diagnosis of chronic otitis media with primary acquired cholesteatoma and assessed preoperatively in our clinic by ear magnetic resonance imaging and DWI were included in the study. Diffusion-weighted imaging results were compared with operative findings and pathology results. Patients were retrospectively evaluated using picture archiving and communication system. Diffusion-weighted imaging and ADC images were examined qualitatively and quantitatively. Ninety-one patients suspected of cholesteatoma were operated. According to the results of operations, 50 patients had cholesteatoma and 41 patients had granulation tissue. The mean DWI values of patients with cholesteatoma were significantly higher than patients with granulation tissue (pgranulation tissue (p<0.05). The sensitivity and specificity of EP-DWI in detection of cholesteatoma were 97.6% and 92.0%, respectively. Echo-planar diffusion-weighted imaging by using ADC and DWI is a valuable tool with high sensitivity and specificity rates in detecting cholesteatoma particularly bigger than 5 mm and in differentiating them from other pathologies.

  12. Functional MRI studies of human vision on a clinical imager

    International Nuclear Information System (INIS)

    George, J.S.; Lewine, J.D.; Aine, C.J.; van Hulsteyn, D.; Wood, C.C.; Sanders, J.; Maclin, E.; Belliveau, J.W.; Caprihan, A.

    1992-01-01

    During the past decade, Magnetic Resonance Imaging (MRI) has become the method of choice for imaging the anatomy of the human brain. Recently, Belliveau and colleagues have reported the use of echo planar magnetic resonance imaging (EPI) to image patterns of neural activity. Here, we report functional MR imaging in response to visual stimulation without the use of contrast agents, and without the extensive hardware modifications required for EPI. Regions of activity were observed near the expected locations of V1, V2 and possibly V3 and another active region was observed near the parietal-occipital sulcus on the superior surface of the cerebrum. These locations are consistent with sources observed in neuromagnetic studies of the human visual response

  13. Functional imaging of the sensorimotor cortex using an ultra-fast MR imaging method

    International Nuclear Information System (INIS)

    Tsunoda, Akira; Nakajima, Yasoichi; Sato, Kiyoshi; Katayama, Jin; Machida, Yoshio; Nozaki, Seiji; Makita, Jun-ichi.

    1996-01-01

    The aim of this study was to assess changes in brain activity during a motor task and variable sensory stimulation using echo planar imaging, which represents the fastest clinically useful imaging technique available. The subjects of this study were 11 healthy volunteers, 4 males and 11 females, with an average of 26.4 years. The subjects were instructed to tap the fingers of one hand as the motor task. Compressed air was applied 5 times a second as 'simple' sensory stimulation. Simple figures were drawn on the subjects palm as 'complex' sensory stimulation. In all cases, functional imaging was performed by T 2 * -weighted echo planar imaging (TE=53 msec, TR=3000 msec, flip angle=90 degrees, matrix 64 x 64, FOV=205 mm, slice thickness=8 mm) alternately at rest and during the task (intervals: 30 sec). A total of 60 images was collected in 3 minutes. Images obtained by subtracting images at rest and during the task were analyzed. Almost all subjects showed a transient signal increase in the contralateral paracentral region during simple sensory stimulation. Continuous signal increases in the contra- and/or ipsi-lateral para-central region were observed durirg complex sensory stimulation. Some exhibited signal increases in the parietal or frontal association cortex, but they disappeared when subject's attention was distracted during stimulation. All subjects displayed signal increases in the contralateral para-central region during the motor task. Some of them exhibited signal increases in the medial frontal area (supplementary motor area) and ipsilateral para-central region. These results suggest that the signal increases of functional MRI reflect not only simple reactions to stimulation but higher cerebral function as well. (J.P.N.)

  14. Parallel magnetic resonance imaging

    International Nuclear Information System (INIS)

    Larkman, David J; Nunes, Rita G

    2007-01-01

    Parallel imaging has been the single biggest innovation in magnetic resonance imaging in the last decade. The use of multiple receiver coils to augment the time consuming Fourier encoding has reduced acquisition times significantly. This increase in speed comes at a time when other approaches to acquisition time reduction were reaching engineering and human limits. A brief summary of spatial encoding in MRI is followed by an introduction to the problem parallel imaging is designed to solve. There are a large number of parallel reconstruction algorithms; this article reviews a cross-section, SENSE, SMASH, g-SMASH and GRAPPA, selected to demonstrate the different approaches. Theoretical (the g-factor) and practical (coil design) limits to acquisition speed are reviewed. The practical implementation of parallel imaging is also discussed, in particular coil calibration. How to recognize potential failure modes and their associated artefacts are shown. Well-established applications including angiography, cardiac imaging and applications using echo planar imaging are reviewed and we discuss what makes a good application for parallel imaging. Finally, active research areas where parallel imaging is being used to improve data quality by repairing artefacted images are also reviewed. (invited topical review)

  15. Correlated spectroscopic imaging of calf muscle in three spatial dimensions using group sparse reconstruction of undersampled single and multichannel data.

    Science.gov (United States)

    Wilson, Neil E; Burns, Brian L; Iqbal, Zohaib; Thomas, M Albert

    2015-11-01

    To implement a 5D (three spatial + two spectral) correlated spectroscopic imaging sequence for application to human calf. Nonuniform sampling was applied across the two phase encoded dimensions and the indirect spectral dimension of an echo planar-correlated spectroscopic imaging sequence. Reconstruction was applied that minimized the group sparse mixed ℓ2,1-norm of the data. Multichannel data were compressed using a sensitivity map-based approach with a spatially dependent transform matrix and utilized the self-sparsity of the individual coil images to simplify the reconstruction. Single channel data with 8× and 16× undersampling are shown in the calf of a diabetic patient. A 15-channel scan with 12× undersampling of a healthy volunteer was reconstructed using 5 virtual channels and compared to a fully sampled single slice scan. Group sparse reconstruction faithfully reconstructs the lipid cross peaks much better than ℓ1 minimization. COSY spectra can be acquired over a 3D spatial volume with scan time under 15 min using echo planar readout with highly undersampled data and group sparse reconstruction. © 2015 Wiley Periodicals, Inc.

  16. In-line digital holographic imaging in volume holographic microscopy.

    Science.gov (United States)

    Zhai, Xiaomin; Lin, Wei-Tang; Chen, Hsi-Hsun; Wang, Po-Hao; Yeh, Li-Hao; Tsai, Jui-Chang; Singh, Vijay Raj; Luo, Yuan

    2015-12-01

    A dual-plane in-line digital holographic imaging method incorporating volume holographic microscopy (VHM) is presented to reconstruct objects in a single shot while eliminating zero-order and twin-image diffracted waves. The proposed imaging method is configured such that information from different axial planes is acquired simultaneously using multiplexed volume holographic imaging gratings, as used in VHM, and recorded as in-line holograms where the corresponding reference beams are generated in the fashion of Gabor's in-line holography. Unlike conventional VHM, which can take axial intensity information only at focal depths, the proposed method digitally reconstructs objects at any axial position. Further, we demonstrate the proposed imaging technique's ability to effectively eliminate zero-order and twin images for single-shot three-dimensional object reconstruction.

  17. Simultaneous multislice (SMS) imaging techniques.

    Science.gov (United States)

    Barth, Markus; Breuer, Felix; Koopmans, Peter J; Norris, David G; Poser, Benedikt A

    2016-01-01

    Simultaneous multislice imaging (SMS) using parallel image reconstruction has rapidly advanced to become a major imaging technique. The primary benefit is an acceleration in data acquisition that is equal to the number of simultaneously excited slices. Unlike in-plane parallel imaging this can have only a marginal intrinsic signal-to-noise ratio penalty, and the full acceleration is attainable at fixed echo time, as is required for many echo planar imaging applications. Furthermore, for some implementations SMS techniques can reduce radiofrequency (RF) power deposition. In this review the current state of the art of SMS imaging is presented. In the Introduction, a historical overview is given of the history of SMS excitation in MRI. The following section on RF pulses gives both the theoretical background and practical application. The section on encoding and reconstruction shows how the collapsed multislice images can be disentangled by means of the transmitter pulse phase, gradient pulses, and most importantly using multichannel receiver coils. The relationship between classic parallel imaging techniques and SMS reconstruction methods is explored. The subsequent section describes the practical implementation, including the acquisition of reference data, and slice cross-talk. Published applications of SMS imaging are then reviewed, and the article concludes with an outlook and perspective of SMS imaging. © 2015 Wiley Periodicals, Inc.

  18. Increased self-diffusion of brain water in hydrocephalus measured by MR imaging

    DEFF Research Database (Denmark)

    Gideon, P; Thomsen, C; Gjerris, F

    1994-01-01

    We used MR imaging to measure the apparent brain water self-diffusion in 5 patients with normal pressure hydrocephalus (NPH), in 2 patients with high pressure hydrocephalus (HPH), and in 8 age-matched controls. In all patients with NPH significant elevations of the apparent diffusion coefficients...... white matter, and in one patient reexamined one year after surgery, ADCs were unchanged in nearly all brain regions. The increased ADC values in hydrocephalus patients may be caused by factors such as changes in myelin-associated bound water, increased Virchow-Robin spaces, and increased extracellular...... brain water fraction. For further studies of brain water diffusion in hydrocephalus patients, echo-planar imaging techniques with imaging times of a few seconds may be valuable....

  19. Magnetic Resonance Imaging Including Magnetic Resonance Cholangiopancreatography for Tumor Localization and Therapy Planning in Malignant Hilar Obstructions

    International Nuclear Information System (INIS)

    Haenninen, E.L.

    2005-01-01

    PURPOSE: To assess image quality and overall accuracy of magnetic resonance imaging (MRI), including two magnetic cholangiopancreatography (MRCP) techniques, for the diagnostics and preoperative work-up of malignant hilar obstructions. MATERIAL AND METHODS: Thirty-one patients with malignant hilar obstructions (hilar cholangiocarcinoma, n=30; hepatocellular carcinoma, n=1) received MRCP by two techniques (single-shot thick-slab and multisection thin-slice MRCP) and unenhanced and contrast material-enhanced MRI. MR assessment included the evaluation of image quality and visualization of bile ducts (5-point scale), and the classification of tumor status. MR results were subsequently correlated with the results from surgery and pathology. RESULTS: The maximum intensity projections of multisection thin-slice MRCP had significantly more artifacts compared to MRCP in the single-shot thick-slab technique, and overall image quality of single-shot thick-slab MRCP was rated significantly superior compared to multisection thin-slice MRCP (4.4 ± 0.7 and 4.1 ± 0.9, respectively). Moreover, ductal visualization of different parts of the biliary system was rated superior with single-shot thick-slab MRCP. In contrast, the original data from multisection thin slice MRCP facilitated visualization of periductal lesions and adjacent structures. Overall MR accuracy for the assessment of tumor status, periductal infiltration, and lymph node metastases was 90%, 87%, and 66%, respectively. CONCLUSION: For evaluation of malignant hilar obstructions, MRCP by the single-shot thick-slab technique had superior image quality and fewer artifacts; in contrast, besides sole biliary visualization, multisection MRCP depicted complementary adjacent parenchymal and periductal structures. We therefore recommend MRI, with a combination of both MRCP techniques, for the diagnostic work-up and therapy planning of malignant hilar obstructions

  20. Diffusion weighted whole body imaging with background body signal suppression (DWIBS). Technical improvement using free breathing, STIR and high resolution 3D display

    International Nuclear Information System (INIS)

    Takahara, Taro; Imai, Yutaka; Yamashita, Tomohiro; Yasuda, Seiei; Nasu, Seiji; Cauteren, M. Van

    2004-01-01

    The purpose of this study was to examine a new way of body diffusion weighted imaging (DWI) using the short TI inversion recovery-echo planar imaging (STIR-EPI) sequence and free breathing scanning (diffusion weighted whole body imaging with background body signal suppression; DWIBS) to obtain three-dimensional displays. Apparent contrast-to-noise ratios (AppCNR) between lymph nodes and surrounding fat tissue were compared in three types of DWI with and without breath-holding, with variable lengths of scan time and slice thickness. The STIR-EPI sequence and spin echo-echo planar imaging (SE-EPI) sequence with chemical shift selective (CHESS) pulse were compared in terms of their degree of fat suppression. Eleven patients with neck, chest, and abdominal malignancy were scanned with DWIBS for evaluation of feasibility. Whole body imaging was done in a later stage of the study using the peripheral vascular coil. The AppCNR of 8 mm slice thickness images reconstructed from 4 mm slice thickness source images obtained in a free breathing scan of 430 sec were much better than 9 mm slice thickness breath-hold scans obtained in 25 sec. High resolution multi-planar reformat (MPR) and maximum intensity projection (MIP) images could be made from the data set of 4 mm slice thickness images. Fat suppression was much better in the STIR-EPI sequence than SE-EPI with CHESS pulse. The feasibility of DWIBS was showed in clinical scans of 11 patients. Whole body images were successfully obtained with adequate fat suppression. Three-dimensional DWIBS can be obtained with this technique, which may allow us to screen for malignancies in the whole body. (author)

  1. Multiscale deformable registration for dual-energy x-ray imaging

    OpenAIRE

    Gang, G. J.; Varon, C. A.; Kashani, H.; Richard, S.; Paul, N. S.; Van Metter, R.; Yorkston, J.; Siewerdsen, J. H.

    2009-01-01

    Dual-energy (DE) imaging of the chest improves the conspicuity of subtle lung nodules through the removal of overlying anatomical noise. Recent work has shown double-shot DE imaging (i.e., successive acquisition of low- and high-energy projections) to provide detective quantum efficiency, spectral separation (and therefore contrast), and radiation dose superior to single-shot DE imaging configurations (e.g., with a CR cassette). However, the temporal separation between high-energy (HE) and lo...

  2. Free-breathing motion-corrected late-gadolinium-enhancement imaging improves image quality in children

    Energy Technology Data Exchange (ETDEWEB)

    Olivieri, Laura; O' Brien, Kendall J. [Children' s National Health System, Division of Cardiology, Washington, DC (United States); National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD (United States); Cross, Russell [Children' s National Health System, Division of Cardiology, Washington, DC (United States); Xue, Hui; Kellman, Peter; Hansen, Michael S. [National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD (United States)

    2016-06-15

    The value of late-gadolinium-enhancement (LGE) imaging in the diagnosis and management of pediatric and congenital heart disease is clear; however current acquisition techniques are susceptible to error and artifacts when performed in children because of children's higher heart rates, higher prevalence of sinus arrhythmia, and inability to breath-hold. Commonly used techniques in pediatric LGE imaging include breath-held segmented FLASH (segFLASH) and steady-state free precession-based (segSSFP) imaging. More recently, single-shot SSFP techniques with respiratory motion-corrected averaging have emerged. This study tested and compared single-shot free-breathing LGE techniques with standard segmented breath-held techniques in children undergoing LGE imaging. Thirty-two consecutive children underwent clinically indicated late-enhancement imaging using intravenous gadobutrol 0.15 mmol/kg. Breath-held segSSFP, breath-held segFLASH, and free-breathing single-shot SSFP LGE sequences were performed in consecutive series in each child. Two blinded reviewers evaluated the quality of the images and rated them on a scale of 1-5 (1 = poor, 5 = superior) based on blood pool-myocardial definition, presence of cardiac motion, presence of respiratory motion artifacts, and image acquisition artifact. We used analysis of variance (ANOVA) to compare groups. Patients ranged in age from 9 months to 18 years, with a mean +/- standard deviation (SD) of 13.3 +/- 4.8 years. R-R interval at the time of acquisition ranged 366-1,265 milliseconds (ms) (47-164 beats per minute [bpm]), mean +/- SD of 843+/-231 ms (72+/-21 bpm). Mean +/- SD quality ratings for long-axis imaging for segFLASH, segSSFP and single-shot SSFP were 3.1+/-0.9, 3.4+/-0.9 and 4.0+/-0.9, respectively (P < 0.01 by ANOVA). Mean +/- SD quality ratings for short-axis imaging for segFLASH, segSSFP and single-shot SSFP were 3.4+/-1, 3.8+/-0.9 and 4.3+/-0.7, respectively (P < 0.01 by ANOVA). Single-shot late

  3. Free-breathing motion-corrected late-gadolinium-enhancement imaging improves image quality in children

    International Nuclear Information System (INIS)

    Olivieri, Laura; O'Brien, Kendall J.; Cross, Russell; Xue, Hui; Kellman, Peter; Hansen, Michael S.

    2016-01-01

    The value of late-gadolinium-enhancement (LGE) imaging in the diagnosis and management of pediatric and congenital heart disease is clear; however current acquisition techniques are susceptible to error and artifacts when performed in children because of children's higher heart rates, higher prevalence of sinus arrhythmia, and inability to breath-hold. Commonly used techniques in pediatric LGE imaging include breath-held segmented FLASH (segFLASH) and steady-state free precession-based (segSSFP) imaging. More recently, single-shot SSFP techniques with respiratory motion-corrected averaging have emerged. This study tested and compared single-shot free-breathing LGE techniques with standard segmented breath-held techniques in children undergoing LGE imaging. Thirty-two consecutive children underwent clinically indicated late-enhancement imaging using intravenous gadobutrol 0.15 mmol/kg. Breath-held segSSFP, breath-held segFLASH, and free-breathing single-shot SSFP LGE sequences were performed in consecutive series in each child. Two blinded reviewers evaluated the quality of the images and rated them on a scale of 1-5 (1 = poor, 5 = superior) based on blood pool-myocardial definition, presence of cardiac motion, presence of respiratory motion artifacts, and image acquisition artifact. We used analysis of variance (ANOVA) to compare groups. Patients ranged in age from 9 months to 18 years, with a mean +/- standard deviation (SD) of 13.3 +/- 4.8 years. R-R interval at the time of acquisition ranged 366-1,265 milliseconds (ms) (47-164 beats per minute [bpm]), mean +/- SD of 843+/-231 ms (72+/-21 bpm). Mean +/- SD quality ratings for long-axis imaging for segFLASH, segSSFP and single-shot SSFP were 3.1+/-0.9, 3.4+/-0.9 and 4.0+/-0.9, respectively (P < 0.01 by ANOVA). Mean +/- SD quality ratings for short-axis imaging for segFLASH, segSSFP and single-shot SSFP were 3.4+/-1, 3.8+/-0.9 and 4.3+/-0.7, respectively (P < 0.01 by ANOVA). Single-shot late

  4. SU-E-I-12: Characterization of Edge Effects in a Commercial Low-Dose Image Processing System

    Energy Technology Data Exchange (ETDEWEB)

    Marsh, R; Silosky, M [University of Colorado School of Medicine, Aurora, CO (United States)

    2014-06-01

    Purpose: Minimizing radiation dose while preserving image quality is critical in fluoroscopic imaging. One recent development is a noise reduction system (Allura Clarity) offered by Philips. Others have reported approximately 50% reduction in air kerma when using Clarity. These studies, however, provide only a cursory look at how the Clarity system affects image quality. The purpose of this work was to evaluate the effect of Clarity on the appearance of high-frequency image information. Methods: A lead attenuator with a smooth edge was imaged on two Philips Allura FD20 detectors: one with Clarity and one without. The edge was positioned in the center of the field of view and images were obtained under the following conditions: 40cm and 11cm fields of view, single shot and continuous fluoroscopy modes, and using abdomen and cardiac protocols, for a total of sixteen imaging conditions. Profiles were drawn perpendicular to the edge across 80% of its length, averaged to reduce noise, normalized to the maximum pixel value, and plotted as a function of distance. Results: For all single-shot acquisitions and most fluoroscopic images, overshoot of the edge was observed. This effect was more substantial for single-shot acquisitions (∼20%) than for fluoroscopic images (∼50%). For fluoroscopic acquisition, the overshoot decayed more quickly with the Clarity system. However, the system with Clarity introduced a ringing effect for both single-shot and fluoroscopic images that is not present on the non-Clarity system. Conclusion: Previous reports have demonstrated a substantial dose reduction when using Clarity but the impact this has on image appearance has not been characterized. One demonstrated difference is the change in appearance of high-frequency image information. It remains to be determined whether this effect may impact clinical images adversely.

  5. Diagnosis of chest wall invasion by lung cancer. Useful criteria for exclusion of the possibility of chest wall invasion with MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Shiotani, Seiji [Tsukuba Medical Center, Ibaraki (Japan); Sugimura, Kazuro; Sugihara, Masaki (and others)

    2000-10-01

    To compare the accuracy of thin-section CT, conventional static MR imaging (conventional MRI), and breathing dynamic echo planar magnetic resonance imaging (BDEPI) in evaluating lung cancer invasion to the chest wall. Thin-section CT, conventional MRI, and BDEPI were performed preoperatively in 20 patients suspected of having primary lung cancers adjacent to the chest wall on conventional CT. The results of imaging findings were compared with those of surgical and histopathological findings. All patients were confirmed to have no chest wall invasion after surgery. By thin-section CT, 10 of 20 patients were correctly diagnosed as having no chest wall invasion (50% specificity). Two of the 20 patients were incorrectly diagnosed as having chest wall invasion by conventional MRI and BDEPI (90% specificity). When chest wall invasion is suspected on CT scans, static and breathing dynamic MRI are recommended to avoid false positive interpretations. (author)

  6. The value of diffusion-weighted imaging for prediction of lasting deficit in acute stroke: an analysis of 134 patients with acute neurologic deficits

    International Nuclear Information System (INIS)

    Wiener, J.I.; King, J.T. Jr.; Moore, J.R.; Lewin, J.S.

    2001-01-01

    Acute stroke is one of the three major causes of death and disability in the United States. Now that new, and possibly effective therapy is becoming available, accurate, rapid diagnosis is important to provide timely treatment, while avoiding the risk of complications from unnecessary intervention. Our objective was to test the hypothesis that use of echo-planar (EPI) diffusion-weighted imaging (DWI) is more accurate than conventional T 2 weighted MRI in predicting progression to stroke in patients with acute ischemic neurologic deficits. We studied 134 patients presenting with acute neurologic deficits to a community hospital emergency room with both conventional MRI and DWI within 72 h of the onset of the acute deficit. We found DWI significantly more sensitive to permanent neurologic deficit at discharge (sensitivity 0.81) than conventional MRI (sensitivity 0.41). When available, DWI should be considered for routine use in patients being imaged for acute stroke. (orig.)

  7. Imaging of postoperative middle ear cholesteatoma

    International Nuclear Information System (INIS)

    Khemani, S.; Singh, A.; Lingam, R.K.; Kalan, A.

    2011-01-01

    Cholesteatoma is often treated surgically using canal wall-preserving techniques. Clinical and otoscopic diagnosis of residual or recurrent disease after this form of surgery is unreliable and thus radiological imaging is often used prior to mandatory 'second-look' surgery. Imaging needs to be able to differentiate residual or recurrent disease from granulation tissue, inflammatory tissue or fluid within the middle ear cavity and mastoid cavity. High-resolution computed tomography (HRCT), conventional magnetic resonance imaging (MRI), and delayed contrast MRI have all been used in detecting postoperative cholesteatoma. Although delayed contrast MRI performs better than HRCT and conventional MRI, the sensitivities and specificities of these different imaging methods are relatively poor. Diffusion-weighted MRI (DWI and, in particular, non-echo planar DWI) has been shown to have a high sensitivity and specificity for detecting recurrent cholesteatoma. In this review we provide examples of postoperative imaging appearances following cholesteatoma surgery and we review the relevant literature with an emphasis on studies evaluating the diagnostic accuracy of DWI.

  8. Incidental ferumoxytol artifacts in clinical brain MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Bowser, Bruce A.; Campeau, Norbert G.; Carr, Carrie M.; Diehn, Felix E.; McDonald, Jennifer S.; Miller, Gary M.; Kaufmann, Timothy J. [Mayo Clinic, Department of Radiology, Rochester, MN (United States)

    2016-11-15

    Ferumoxytol (Feraheme) is a parenteral therapy approved for treatment of iron deficiency anemia. The product insert for ferumoxytol states that it may affect the diagnostic ability of MRI for up to 3 months. However, the expected effects may not be commonly recognized among clinical neuroradiologists. Our purpose is to describe the artifacts we have seen at our institution during routine clinical practice. We reviewed the patients at our institution that had brain MRI performed within 90 days of receiving intravenous ferumoxytol. The imaging was reviewed for specific findings, including diffusion-weighted imaging vascular susceptibility artifact, gradient-echo echo-planar T2*-weighted vascular susceptibility artifact, SWI/SWAN vascular susceptibility artifact, hypointense vascular signal on T2-weighted images, pre-gadolinium contrast vascular enhancement on magnetization-prepared rapid acquisition gradient echo (MPRAGE) imaging, and effects on post-gadolinium contrast T1 imaging. Multiple artifacts were observed in patients having a brain MRI within 3 days of receiving intravenous ferumoxytol. These included susceptibility artifact on DWI, GRE, and SWAN/SWI imaging, pre-gadolinium contrast increased vascular signal on MPRAGE imaging, and decreased expected enhancement on post-gadolinium contrast T1-weighted imaging. Ferumoxytol can create imaging artifacts which complicate clinical interpretation when brain MRI is performed within 3 days of administration. Recognition of the constellation of artifacts produced by ferumoxytol is important in order to obviate additional unnecessary examinations and mitigate errors in interpretation. (orig.)

  9. Restoring susceptibility induced MRI signal loss in rat brain at 9.4 T: A step towards whole brain functional connectivity imaging.

    Directory of Open Access Journals (Sweden)

    Rupeng Li

    Full Text Available The aural cavity magnetic susceptibility artifact leads to significant echo planar imaging (EPI signal dropout in rat deep brain that limits acquisition of functional connectivity fcMRI data. In this study, we provide a method that recovers much of the EPI signal in deep brain. Needle puncture introduction of a liquid-phase fluorocarbon into the middle ear allows acquisition of rat fcMRI data without signal dropout. We demonstrate that with seeds chosen from previously unavailable areas, including the amygdala and the insular cortex, we are able to acquire large scale networks, including the limbic system. This tool allows EPI-based neuroscience and pharmaceutical research in rat brain using fcMRI that was previously not feasible.

  10. Imaging and electron energy-loss spectroscopy using single nanosecond electron pulses.

    Science.gov (United States)

    Picher, Matthieu; Bücker, Kerstin; LaGrange, Thomas; Banhart, Florian

    2018-03-13

    We implement a parametric study with single electron pulses having a 7 ns duration to find the optimal conditions for imaging, diffraction, and electron energy-loss spectroscopy (EELS) in the single-shot approach. Photoelectron pulses are generated by illuminating a flat tantalum cathode with 213 nm nanosecond laser pulses in a 200 kV transmission electron microscope (TEM) with thermionic gun and Wehnelt electrode. For the first time, an EEL spectrometer is used to measure the energy distribution of single nanosecond electron pulses which is crucial for understanding the ideal imaging conditions of the single-shot approach. By varying the laser power, the Wehnelt bias, and the condenser lens settings, the optimum TEM operation conditions for the single-shot approach are revealed. Due to space charge and the Boersch effect, the energy width of the pulses under maximized emission conditions is far too high for imaging or spectroscopy. However, by using the Wehnelt electrode as an energy filter, the energy width of the pulses can be reduced to 2 eV, though at the expense of intensity. The first EEL spectra taken with nanosecond electron pulses are shown in this study. With 7 ns pulses, an image resolution of 25 nm is attained. It is shown how the spherical and chromatic aberrations of the objective lens as well as shot noise limit the resolution. We summarize by giving perspectives for improving the single-shot time-resolved approach by using aberration correction. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Functional MRI using regularized parallel imaging acquisition.

    Science.gov (United States)

    Lin, Fa-Hsuan; Huang, Teng-Yi; Chen, Nan-Kuei; Wang, Fu-Nien; Stufflebeam, Steven M; Belliveau, John W; Wald, Lawrence L; Kwong, Kenneth K

    2005-08-01

    Parallel MRI techniques reconstruct full-FOV images from undersampled k-space data by using the uncorrelated information from RF array coil elements. One disadvantage of parallel MRI is that the image signal-to-noise ratio (SNR) is degraded because of the reduced data samples and the spatially correlated nature of multiple RF receivers. Regularization has been proposed to mitigate the SNR loss originating due to the latter reason. Since it is necessary to utilize static prior to regularization, the dynamic contrast-to-noise ratio (CNR) in parallel MRI will be affected. In this paper we investigate the CNR of regularized sensitivity encoding (SENSE) acquisitions. We propose to implement regularized parallel MRI acquisitions in functional MRI (fMRI) experiments by incorporating the prior from combined segmented echo-planar imaging (EPI) acquisition into SENSE reconstructions. We investigated the impact of regularization on the CNR by performing parametric simulations at various BOLD contrasts, acceleration rates, and sizes of the active brain areas. As quantified by receiver operating characteristic (ROC) analysis, the simulations suggest that the detection power of SENSE fMRI can be improved by regularized reconstructions, compared to unregularized reconstructions. Human motor and visual fMRI data acquired at different field strengths and array coils also demonstrate that regularized SENSE improves the detection of functionally active brain regions. 2005 Wiley-Liss, Inc

  12. Exploring brain function with magnetic resonance imaging

    International Nuclear Information System (INIS)

    Di Salle, F.; Formisano, E.; Linden, D.E.J.; Goebel, R.; Bonavita, S.; Pepino, A.; Smaltino, F.; Tedeschi, G.

    1999-01-01

    Since its invention in the early 1990s, functional magnetic resonance imaging (fMRI) has rapidly assumed a leading role among the techniques used to localize brain activity. The spatial and temporal resolution provided by state-of-the-art MR technology and its non-invasive character, which allows multiple studies of the same subject, are some of the main advantages of fMRI over the other functional neuroimaging modalities that are based on changes in blood flow and cortical metabolism. This paper describes the basic principles and methodology of fMRI and some aspects of its application to functional activation studies. Attention is focused on the physiology of the blood oxygenation level-dependent (BOLD) contrast mechanism and on the acquisition of functional time-series with echo planar imaging (EPI). We also provide an introduction to the current strategies for the correction of signal artefacts and other image processing techniques. In order to convey an idea of the numerous applications of fMRI, we will review some of the recent results in the fields of cognitive and sensorimotor psychology and physiology

  13. Feasibility and resolution limits of opto-magnetic imaging of neural network activity in brain slices using color centers in diamond

    DEFF Research Database (Denmark)

    Karadas, Mürsel; Wojciechowski, Adam M; Huck, Alexander

    2018-01-01

    activity and has strongly contributed to our understanding of the mechanisms that govern neural information processing. However, this traditional approach only acquires signals from a few positions, which severely limits its ability to characterize the dynamics of the underlying neural networks. We suggest...... cell. Our results suggest that imaging of slice activity will be possible with the upcoming generation of NV magnetic field sensors, while single-shot imaging of planar cell activity remains challenging....

  14. Breast cancer detection using double reading of unenhanced MRI including T1-weighted, T2-weighted STIR, and diffusion-weighted imaging: a proof of concept study.

    Science.gov (United States)

    Trimboli, Rubina M; Verardi, Nicola; Cartia, Francesco; Carbonaro, Luca A; Sardanelli, Francesco

    2014-09-01

    The purpose of this study was to investigate the diagnostic performance of unenhanced MRI in detecting breast cancer and to assess the impact of double reading. A total of 116 breasts of 67 women who were 36-89 years old were studied at 1.5 T using an unenhanced protocol including axial T1-weighted gradient-echo, T2-weighted STIR, and echo-planar diffusion-weighted imaging (DWI). Two blinded readers (R1 and R2) independently evaluated unenhanced images using the BIRADS scale. A combination of pathology and negative follow-up served as the reference standard. McNemar and kappa statistics were used. Per-breast cancer prevalence was 37 of 116 (32%): 30 of 37 (81%) invasive ductal carcinoma, five of 37 (13%) ductal carcinoma in situ, and two of 37 (6%) invasive lobular carcinoma. Per-breast sensitivity of unenhanced MRI was 29 of 37 (78%) for R1, 28 of 37 (76%) for R2, and 29 of 37 (78%) for double reading. Specificity was 71 of 79 (90%) for both R1 and R2 and 69 of 79 (87%) for double reading. Double reading did not provide a significant increase in sensitivity. Interobserver agreement was almost perfect (Cohen κ = 0.873). An unenhanced breast MRI protocol composed of T1-weighted gradient echo, T2-weighted STIR, and echo-planar DWI enabled breast cancer detection with sensitivity of 76-78% and specificity of 90% without a gain in sensitivity from double reading.

  15. Diffusion-weighted MR imaging (DWI) in spinal cord ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Thurnher, Majda M. [Medical University of Vienna, Department of Radiology, Neuroradiology Section, Vienna (Austria); Bammer, Roland [Stanford University, Lucas MRS/I Center, Department of Radiology, Stanford, CA (United States)

    2006-11-15

    Spinal cord infarction is a rare clinical diagnosis characterized by a sudden onset of paralysis, bowel and bladder dysfunction, and loss of pain and temperature perception, with preservation of proprioception and vibration sense. Magnetic resonance imaging (MRI) usually demonstrates intramedullary hyperintensity on T2-weighted MR images with cord enlargement. However, in approximately 45% of patients, MR shows no abnormality. Diffusion-weighted MR imaging (DWI) has been widely used for the evaluation of a variety of brain disorders, especially for acute stroke. Preliminary data suggest that DWI has the potential to be useful in the early detection of spinal infarction. We performed DWI, using navigated, interleaved, multishot echo planar imaging (IEPI), in a series of six patients with a clinical suspicion of acute spinal cord ischemia. In all patients, high signal was observed on isotropic DWI images with low ADC values (0.23 and 0.86 x 10{sup -3} cm{sup 2}/s), indicative of restricted diffusion. We analyzed the imaging findings from conventional MR sequences and diffusion-weighted MR sequences in six patients with spinal cord infarction, compared the findings with those in published series, and discuss the value of DWI in spinal cord ischemia based on current experience. Although the number of patients with described DWI findings totals only 23, the results of previously published studies and those of our study suggest that DWI has the potential to be a useful and feasible technique for the detection of spinal infarction. (orig.)

  16. Diffusion-weighted MR imaging (DWI) in spinal cord ischemia

    International Nuclear Information System (INIS)

    Thurnher, Majda M.; Bammer, Roland

    2006-01-01

    Spinal cord infarction is a rare clinical diagnosis characterized by a sudden onset of paralysis, bowel and bladder dysfunction, and loss of pain and temperature perception, with preservation of proprioception and vibration sense. Magnetic resonance imaging (MRI) usually demonstrates intramedullary hyperintensity on T2-weighted MR images with cord enlargement. However, in approximately 45% of patients, MR shows no abnormality. Diffusion-weighted MR imaging (DWI) has been widely used for the evaluation of a variety of brain disorders, especially for acute stroke. Preliminary data suggest that DWI has the potential to be useful in the early detection of spinal infarction. We performed DWI, using navigated, interleaved, multishot echo planar imaging (IEPI), in a series of six patients with a clinical suspicion of acute spinal cord ischemia. In all patients, high signal was observed on isotropic DWI images with low ADC values (0.23 and 0.86 x 10 -3 cm 2 /s), indicative of restricted diffusion. We analyzed the imaging findings from conventional MR sequences and diffusion-weighted MR sequences in six patients with spinal cord infarction, compared the findings with those in published series, and discuss the value of DWI in spinal cord ischemia based on current experience. Although the number of patients with described DWI findings totals only 23, the results of previously published studies and those of our study suggest that DWI has the potential to be a useful and feasible technique for the detection of spinal infarction. (orig.)

  17. Clinical application of functional magnetic resonance imaging

    CERN Document Server

    Alwatban, A Z W

    2002-01-01

    The work described in this thesis was carried out at the Magnetic Resonance Centre of the University of Nottingham during the time from May 1998 to April 2001, and is the work of the except where indicated by reference. The main source of signal changes in functional magnetic resonance imaging (fMRJ) is the fluctuation of paramagnetic deoxyhaemoglobin in the venous blood during different states of functional performance. For the work of this thesis, fMRI studies were carried out using a 3 T MR system with an echo planar imaging (EPI) pulse sequence. Hearing research utilising fMRI has been previously reported in normal subjects. Hearing fMRI is normally performed by stimulating the auditory cortex via an acoustic task presentation such as music, tone, etc. However, performing the same research on deaf subjects requires special equipment to be designed to allow direct stimulation of the auditory nerve. In this thesis, a new method of direct electrical stimulation of the auditory nerve is described that uses a ...

  18. Preoperative subtyping of meningiomas by perfusion MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Hao [University Medical Center Groningen, University of Groningen (Netherlands); Shanghai Jiaotong University affiliated First People' s Hospital, Department of Radiology, Shanghai (China); Department of Radiology, University of Groningen (Netherlands); Roediger, Lars A.; Oudkerk, Matthijs [University Medical Center Groningen, University of Groningen (Netherlands); Department of Radiology, University of Groningen (Netherlands); Shen, Tianzhen [Fudan University Huashan Hospital, Department of Radiology, Shanghai (China); Miao, Jingtao [Shanghai Jiaotong University affiliated First People' s Hospital, Department of Radiology, Shanghai (China)

    2008-10-15

    This paper aims to evaluate the value of perfusion magnetic resonance (MR) imaging in the preoperative subtyping of meningiomas by analyzing the relative cerebral blood volume (rCBV) of three benign subtypes and anaplastic meningiomas separately. Thirty-seven meningiomas with peritumoral edema (15 meningothelial, ten fibrous, four angiomatous, and eight anaplastic) underwent perfusion MR imaging by using a gradient echo echo-planar sequence. The maximal rCBV (compared with contralateral normal white matter) in both tumoral parenchyma and peritumoral edema of each tumor was measured. The mean rCBVs of each two histological subtypes were compared using one-way analysis of variance and least significant difference tests. A p value less than 0.05 indicated a statistically significant difference. The mean rCBV of meningothelial, fibrous, angiomatous, and anaplastic meningiomas in tumoral parenchyma were 6.93{+-}3.75, 5.61{+-}4.03, 11.86{+-}1.93, and 5.89{+-}3.85, respectively, and in the peritumoral edema 0.87{+-}0.62, 1.38{+-}1.44, 0.87{+-}0.30, and 3.28{+-}1.39, respectively. The mean rCBV in tumoral parenchyma of angiomatous meningiomas and in the peritumoral edema of anaplastic meningiomas were statistically different (p<0.05) from the other types of meningiomas. Perfusion MR imaging can provide useful functional information on meningiomas and help in the preoperative diagnosis of some subtypes of meningiomas. (orig.)

  19. Single-shot fluctuations in waveguided high-harmonic generation

    NARCIS (Netherlands)

    Goh, S.J.; Tao, Y.; van der Slot, Petrus J.M.; Bastiaens, Hubertus M.J.; Herek, Jennifer Lynn; Biedron, S.G.; Danailov, M.B.; Milton, S.V.; Boller, Klaus J.

    2015-01-01

    For exploring the application potential of coherent soft x-ray (SXR) and extreme ultraviolet radiation (XUV) provided by high-harmonic generation, it is important to characterize the central output parameters. Of specific importance are pulse-to-pulse (shot-to-shot) fluctuations of the high-harmonic

  20. The challenges of single-shot spinal anaesthesia for cesearean ...

    African Journals Online (AJOL)

    An unusual case of morbid obesity, severe hypertension and twin gestation at 36weeks in an unbooked multigravid patient was presented for cesarean section. She was referred from a private clinic to the obstetric emergency unit of the University College Hospital, Ibadan with history of hypertension in pregnancy. She was ...

  1. Generalized INverse imaging (GIN): ultrafast fMRI with physiological noise correction.

    Science.gov (United States)

    Boyacioğlu, Rasim; Barth, Markus

    2013-10-01

    An ultrafast functional magnetic resonance imaging (fMRI) technique, called generalized inverse imaging (GIN), is proposed, which combines inverse imaging with a phase constraint-leading to a less underdetermined reconstruction-and physiological noise correction. A single 3D echo planar imaging (EPI) prescan is sufficient to obtain the necessary coil sensitivity information and reference images that are used to reconstruct standard images, so that standard analysis methods are applicable. A moving dots stimulus paradigm was chosen to assess the performance of GIN. We find that the spatial localization of activation for GIN is comparable to an EPI protocol and that maximum z-scores increase significantly. The high temporal resolution of GIN (50 ms) and the acquisition of the phase information enable unaliased sampling and regression of physiological signals. Using the phase time courses obtained from the 32 channels of the receiver coils as nuisance regressors in a general linear model results in significant improvement of the functional activation, rendering the acquisition of external physiological signals unnecessary. The proposed physiological noise correction can in principle be used for other fMRI protocols, such as simultaneous multislice acquisitions, which acquire the phase information sufficiently fast and sample physiological signals unaliased. Copyright © 2012 Wiley Periodicals, Inc.

  2. High spatial resolution diffusion weighted imaging on clinical 3 T MRI scanners using multislab spiral acquisitions.

    Science.gov (United States)

    Holtrop, Joseph L; Sutton, Bradley P

    2016-04-01

    A diffusion weighted imaging (DWI) approach that is signal-to-noise ratio (SNR) efficient and can be applied to achieve sub-mm resolutions on clinical 3 T systems was developed. The sequence combined a multislab, multishot pulsed gradient spin echo diffusion scheme with spiral readouts for imaging data and navigators. Long data readouts were used to keep the number of shots, and hence total imaging time, for the three-dimensional acquisition short. Image quality was maintained by incorporating a field-inhomogeneity-corrected image reconstruction to remove distortions associated with long data readouts. Additionally, multiple shots were required for the high-resolution images, necessitating motion induced phase correction through the use of efficiently integrated navigator data. The proposed approach is compared with two-dimensional (2-D) acquisitions that use either a spiral or a typical echo-planar imaging (EPI) acquisition to demonstrate the improved SNR efficiency. The proposed technique provided 71% higher SNR efficiency than the standard 2-D EPI approach. The adaptability of the technique to achieve high spatial resolutions is demonstrated by acquiring diffusion tensor imaging data sets with isotropic resolutions of 1.25 and 0.8 mm. The proposed approach allows for SNR-efficient sub-mm acquisitions of DWI data on clinical 3 T systems.

  3. Imaging nanoscale spatial modulation of a relativistic electron beam with a MeV ultrafast electron microscope

    Science.gov (United States)

    Lu, Chao; Jiang, Tao; Liu, Shengguang; Wang, Rui; Zhao, Lingrong; Zhu, Pengfei; Liu, Yaqi; Xu, Jun; Yu, Dapeng; Wan, Weishi; Zhu, Yimei; Xiang, Dao; Zhang, Jie

    2018-03-01

    An accelerator-based MeV ultrafast electron microscope (MUEM) has been proposed as a promising tool to the study structural dynamics at the nanometer spatial scale and the picosecond temporal scale. Here, we report experimental tests of a prototype MUEM where high quality images with nanoscale fine structures were recorded with a pulsed ˜3 MeV picosecond electron beam. The temporal and spatial resolutions of the MUEM operating in the single-shot mode are about 4 ps (FWHM) and 100 nm (FWHM), corresponding to a temporal-spatial resolution of 4 × 10-19 s m, about 2 orders of magnitude higher than that achieved with state-of-the-art single-shot keV UEM. Using this instrument, we offer the demonstration of visualizing the nanoscale periodic spatial modulation of an electron beam, which may be converted into longitudinal density modulation through emittance exchange to enable production of high-power coherent radiation at short wavelengths. Our results mark a great step towards single-shot nanometer-resolution MUEMs and compact intense x-ray sources that may have widespread applications in many areas of science.

  4. Whole-body intravoxel incoherent motion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Filli, Lukas; Wurnig, Moritz C.; Eberhardt, Christian; Guggenberger, Roman; Boss, Andreas [University Hospital Zurich, Department of Radiology, Zurich (Switzerland); Luechinger, Roger [University and ETH Zurich, Institute of Biomedical Technology, Zurich (Switzerland)

    2015-07-15

    To investigate the technical feasibility of whole-body intravoxel incoherent motion (IVIM) imaging. Whole-body MR images of eight healthy volunteers were acquired at 3T using a spin-echo echo-planar imaging sequence with eight b-values. Coronal parametrical whole-body maps of diffusion (D), pseudodiffusion (D*), and the perfusion fraction (F{sub p}) were calculated. Image quality was rated qualitatively by two independent radiologists, and inter-reader reliability was tested with intra-class correlation coefficients (ICCs). Region of interest (ROI) analysis was performed in the brain, liver, kidney, and erector spinae muscle. Depiction of anatomic structures was rated as good on D maps and good to fair on D* and F{sub p} maps. Exemplary mean D (10{sup -3} mm{sup 2}/s), D* (10{sup -3} mm{sup 2}/s) and F{sub p} (%) values (± standard deviation) of the renal cortex were as follows: 1.7 ± 0.2; 15.6 ± 6.5; 20.9 ± 4.4. Inter-observer agreement was ''substantial'' to ''almost perfect'' (ICC = 0.80 - 0.92). The coefficient of variation of D* was significantly lower with the proposed algorithm compared to the conventional algorithm (p < 0.001), indicating higher stability. The proposed IVIM protocol allows computation of parametrical maps with good to fair image quality. Potential future clinical applications may include characterization of widespread disease such as metastatic tumours or inflammatory myopathies. (orig.)

  5. MR diffusion tensor analysis of schizophrenic brain using statistical parametric mapping

    International Nuclear Information System (INIS)

    Yamada, Haruyasu; Abe, Osamu; Kasai, Kiyoto

    2005-01-01

    The purpose of this study is to investigate diffusion anisotropy in the schizophrenic brain by voxel-based analysis of diffusion tensor imaging (DTI), using statistical parametric mapping (SPM). We studied 33 patients with schizophrenia diagnosed by diagnostic and statistical manual of mental disorders (DSM)-IV criteria and 42 matched controls. The data was obtained with a 1.5 T MRI system. We used single-shot spin-echo planar sequences (repetition time/echo time (TR/TE)=5000/102 ms, 5 mm slice thickness and 1.5 mm gap, field of view (FOV)=21 x 21 cm 2 , number of excitation (NEX)=4, 128 x 128 pixel matrix) for diffusion tensor acquisition. Diffusion gradients (b-value of 500 or 1000 s/mm 2 ) were applied on two axes simultaneously. Diffusion properties were measured along 6 non-linear directions. The structural distortion induced by the large diffusion gradients was corrected, based on each T 2 -weighted echo-planar image (b=0 s/mm 2 ). The fractional anisotropy (FA) maps were generated on a voxel-by-voxel basis. T 2 -weighted echo-planar images were then segmented into gray matter, white matter, and cerebrospinal fluid, using SPM (Wellcome Department of Imaging, University College London, UK). All apparent diffusion coefficient (ADC) and FA maps in native space were transformed to the stereotactic space by registering each of the images to the same template image. The normalized data was smoothed and analyzed using SPM. The significant FA decrease in the patient group was found in the uncinate fasciculus, parahippocampal white matter, anterior cingulum and other areas (corrected p<0.05). No significant increased region was noted. Our results may reflect reduced diffusion anisotropy of the white matter pathway of the limbic system as shown by the decreased FA. Manual region-of-interest analysis is usually more sensitive than voxel-based analysis, but it is subjective and difficult to set with anatomical reproducibility. Voxel-based analysis of the diffusion tensor

  6. Diffusion-weighted MR imaging of kidneys in patients with chronic kidney disease: initial study

    International Nuclear Information System (INIS)

    Xu, Xueqin; Fang, Wenqiang; Ling, Huawei; Chai, Weimin; Chen, Kemin

    2010-01-01

    To prospectively evaluate the feasibility of diffusion-weighted (DW) magnetic resonance (MR) imaging in the assessment of renal function in patients with chronic kidney disease (CKD). Seventy-two healthy volunteers and 43 patients underwent coronal echo-planar DW MR imaging of the kidneys with a single breath-hold time of 16 s. The patients were grouped according to five stages as indicated by the K/DOQI CKD (kidney disease outcome quality initiative). The apparent diffusion coefficient (ADC) value of the kidneys was calculated with high b values (b = 500 s/mm 2 ). The ADC values were compared between patients and healthy volunteers, and among different stages. For statistical analysis, Student's t tests, ANOVA, Pearson's correlation tests, and Spearman's correlation tests were used. No difference between the cortex and medulla could be observed on DW images of all volunteers. Patients with CKD had significantly lower renal ADC (t = -4.383, P = 0.000) than volunteers. The ADC values of kidneys were significantly lower than normal at most stages of CKD, except CKD1. There was a negative correlation between the ADCs and serum creatinine (sCr) level (P = 0.000) amongst the patients. Diffusion-weighted MR imaging is feasible in the assessment of renal function, especially in the detection of early stage renal failure of CKD. (orig.)

  7. Time-optimized high-resolution readout-segmented diffusion tensor imaging.

    Directory of Open Access Journals (Sweden)

    Gernot Reishofer

    Full Text Available Readout-segmented echo planar imaging with 2D navigator-based reacquisition is an uprising technique enabling the sampling of high-resolution diffusion images with reduced susceptibility artifacts. However, low signal from the small voxels and long scan times hamper the clinical applicability. Therefore, we introduce a regularization algorithm based on total variation that is applied directly on the entire diffusion tensor. The spatially varying regularization parameter is determined automatically dependent on spatial variations in signal-to-noise ratio thus, avoiding over- or under-regularization. Information about the noise distribution in the diffusion tensor is extracted from the diffusion weighted images by means of complex independent component analysis. Moreover, the combination of those features enables processing of the diffusion data absolutely user independent. Tractography from in vivo data and from a software phantom demonstrate the advantage of the spatially varying regularization compared to un-regularized data with respect to parameters relevant for fiber-tracking such as Mean Fiber Length, Track Count, Volume and Voxel Count. Specifically, for in vivo data findings suggest that tractography results from the regularized diffusion tensor based on one measurement (16 min generates results comparable to the un-regularized data with three averages (48 min. This significant reduction in scan time renders high resolution (1 × 1 × 2.5 mm(3 diffusion tensor imaging of the entire brain applicable in a clinical context.

  8. [Utility of diffusion-weighted magnetic resonance imaging in severe focal traumatic brain injuries].

    Science.gov (United States)

    Prieto-Valderrey, F; Muñiz-Montes, J R; López-García, J A; Villegas-Del Ojo, J; Málaga-Gil, J; Galván-García, R

    2013-01-01

    To describe the apparent diffusion coefficient (ADC) in a series of severe traumatic brain injuries, their clinical and outcome features, and possible implications. A descriptive, observational case-series study was carried out. Patients with severe traumatic brain injuries (TBIs) admitted to the ICU were subjected to MRI study using a 1.5 T scanner. Diffusion-weighted images (DWMR) were obtained using the following echo-planar pulse sequence: TR 10000 ms, TE 126.9 ms, with b values 1000 s/mm2 in the three spatial dimensions. Combining the three sets of images, an isotropic image conforming a map of the mean ADCs was obtained. DWMR was performed in 23 patients with severe TBI admitted to the ICU between 2001 and 2004. In the MR images we selected 26 regions of interest (ROIs) where ADC was recorded. We observed a clear increase in diffusion in non-treated space-occupying lesions versus other types of injuries and the normal values. A poorer outcome was recorded in patients with lower ADC values. Mean ADC in the lesions was greater than the normal values and greater in contusions than in other types of injuries, as an expression of extracellular edema. ADCs were decreased in patients with a poor outcome, suggesting an association between ischemia and the patient prognosis. Copyright © 2011 Elsevier España, S.L. and SEMICYUC. All rights reserved.

  9. Diffusion-weighted MR imaging of kidneys in patients with chronic kidney disease: initial study

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Xueqin; Fang, Wenqiang; Ling, Huawei; Chai, Weimin; Chen, Kemin [Ruijin Hospital Shanghai, Jiaotong University School of Medicine, Department of Radiology, Shanghai (China)

    2010-04-15

    To prospectively evaluate the feasibility of diffusion-weighted (DW) magnetic resonance (MR) imaging in the assessment of renal function in patients with chronic kidney disease (CKD). Seventy-two healthy volunteers and 43 patients underwent coronal echo-planar DW MR imaging of the kidneys with a single breath-hold time of 16 s. The patients were grouped according to five stages as indicated by the K/DOQI CKD (kidney disease outcome quality initiative). The apparent diffusion coefficient (ADC) value of the kidneys was calculated with high b values (b = 500 s/mm{sup 2}). The ADC values were compared between patients and healthy volunteers, and among different stages. For statistical analysis, Student's t tests, ANOVA, Pearson's correlation tests, and Spearman's correlation tests were used. No difference between the cortex and medulla could be observed on DW images of all volunteers. Patients with CKD had significantly lower renal ADC (t = -4.383, P = 0.000) than volunteers. The ADC values of kidneys were significantly lower than normal at most stages of CKD, except CKD1. There was a negative correlation between the ADCs and serum creatinine (sCr) level (P = 0.000) amongst the patients. Diffusion-weighted MR imaging is feasible in the assessment of renal function, especially in the detection of early stage renal failure of CKD. (orig.)

  10. A parallel imaging technique using mutual calibration for split-blade diffusion-weighted PROPELLER.

    Science.gov (United States)

    Li, Zhiqiang; Pipe, James G; Aboussouan, Eric; Karis, John P; Huo, Donglai

    2011-03-01

    Split-blade diffusion-weighted periodically rotated overlapping parallel lines with enhanced reconstruction (DW-PROPELLER) was proposed to address the issues associated with diffusion-weighted echo planar imaging such as geometric distortion and difficulty in high-resolution imaging. The major drawbacks with DW-PROPELLER are its high SAR (especially at 3T) and violation of the Carr-Purcell-Meiboom-Gill condition, which leads to a long scan time and narrow blade. Parallel imaging can reduce scan time and increase blade width; however, it is very challenging to apply standard k-space-based techniques such as GeneRalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) to split-blade DW-PROPELLER due to its narrow blade. In this work, a new calibration scheme is proposed for k-space-based parallel imaging method without the need of additional calibration data, which results in a wider, more stable blade. The in vivo results show that this technique is very promising. Copyright © 2010 Wiley-Liss, Inc.

  11. Zoomed EPI-DWI of the pancreas using two-dimensional spatially-selective radiofrequency excitation pulses.

    Directory of Open Access Journals (Sweden)

    Philipp Riffel

    Full Text Available BACKGROUND: Implementation of DWI in the abdomen is challenging due to artifacts, particularly those arising from differences in tissue susceptibility. Two-dimensional, spatially-selective radiofrequency (RF excitation pulses for single-shot echo-planar imaging (EPI combined with a reduction in the FOV in the phase-encoding direction (i.e. zooming leads to a decreased number of k-space acquisition lines, significantly shortening the EPI echo train and potentially susceptibility artifacts. PURPOSE: To assess the feasibility and image quality of a zoomed diffusion-weighted EPI (z-EPI sequence in MR imaging of the pancreas. The approach is compared to conventional single-shot EPI (c-EPI. MATERIAL AND METHODS: 23 patients who had undergone an MRI study of the abdomen were included in this retrospective study. Examinations were performed on a 3T whole-body MR system (Magnetom Skyra, Siemens equipped with a two-channel fully dynamic parallel transmit array (TimTX TrueShape, Siemens. The acquired sequences consisted of a conventional EPI DWI of the abdomen and a zoomed EPI DWI of the pancreas. For z-EPI, the standard sinc excitation was replaced with a two-dimensional spatially-selective RF pulse using an echo-planar transmit trajectory. Images were evaluated with regard to image blur, respiratory motion artifacts, diagnostic confidence, delineation of the pancreas, and overall scan preference. Additionally ADC values of the pancreatic head, body, and tail were calculated and compared between sequences. RESULTS: The pancreas was better delineated in every case (23/23 with z-EPI versus c-EPI. In every case (23/23, both readers preferred z-EPI overall to c-EPI. With z-EPI there was statistically significantly less image blur (p<0.0001 and respiratory motion artifact compared to c-EPI (p<0.0001. Diagnostic confidence was statistically significantly better with z-EPI (p<0.0001. No statistically significant differences in calculated ADC values were observed

  12. Zoomed EPI-DWI of the pancreas using two-dimensional spatially-selective radiofrequency excitation pulses.

    Science.gov (United States)

    Riffel, Philipp; Michaely, Henrik J; Morelli, John N; Pfeuffer, Josef; Attenberger, Ulrike I; Schoenberg, Stefan O; Haneder, Stefan

    2014-01-01

    Implementation of DWI in the abdomen is challenging due to artifacts, particularly those arising from differences in tissue susceptibility. Two-dimensional, spatially-selective radiofrequency (RF) excitation pulses for single-shot echo-planar imaging (EPI) combined with a reduction in the FOV in the phase-encoding direction (i.e. zooming) leads to a decreased number of k-space acquisition lines, significantly shortening the EPI echo train and potentially susceptibility artifacts. To assess the feasibility and image quality of a zoomed diffusion-weighted EPI (z-EPI) sequence in MR imaging of the pancreas. The approach is compared to conventional single-shot EPI (c-EPI). 23 patients who had undergone an MRI study of the abdomen were included in this retrospective study. Examinations were performed on a 3T whole-body MR system (Magnetom Skyra, Siemens) equipped with a two-channel fully dynamic parallel transmit array (TimTX TrueShape, Siemens). The acquired sequences consisted of a conventional EPI DWI of the abdomen and a zoomed EPI DWI of the pancreas. For z-EPI, the standard sinc excitation was replaced with a two-dimensional spatially-selective RF pulse using an echo-planar transmit trajectory. Images were evaluated with regard to image blur, respiratory motion artifacts, diagnostic confidence, delineation of the pancreas, and overall scan preference. Additionally ADC values of the pancreatic head, body, and tail were calculated and compared between sequences. The pancreas was better delineated in every case (23/23) with z-EPI versus c-EPI. In every case (23/23), both readers preferred z-EPI overall to c-EPI. With z-EPI there was statistically significantly less image blur (p<0.0001) and respiratory motion artifact compared to c-EPI (p<0.0001). Diagnostic confidence was statistically significantly better with z-EPI (p<0.0001). No statistically significant differences in calculated ADC values were observed between the two sequences. Zoomed diffusion-weighted EPI

  13. Assessment of calf muscle contraction by diffusion tensor imaging

    Energy Technology Data Exchange (ETDEWEB)

    Deux, J.F.; Luciani, A.; Zerbib, P.; Kobeiter, H.; Rahmouni, A. [Centre Hospitalo-Universitaire H. Mondor, Assistance Publique-Hopitaux de Paris, Service d' Imagerie Medicale, Creteil (France); Malzy, P. [Centre Hospitalo-Universitaire Lariboisiere, Assistance Publique-Hopitaux de Paris, Service d' Imagerie Medicale, Paris (France); Paragios, N. [Ecole Centrale de Paris, Chatenay Malabris (France); Bassez, G. [Centre Hospitalo-Universitaire H. Mondor, Assistance Publique-Hopitaux de Paris, Service des Maladies Neuro-Musculaires, Creteil (France); Roudot-Thoraval, F. [Centre Hospitalo-Universitaire H. Mondor, Assistance Publique-Hopitaux de Paris, Centre d' Investigation Clinique, Creteil (France); Vignaud, A. [Siemens Medical Division, Paris (France)

    2008-10-15

    The goal of this study was to assess the changes of water diffusion during contraction and elongation of calf muscles using diffusion tensor (DT) MRI in normal volunteers. Twenty volunteers (mean age, 29 {+-} 4 years) underwent DT MRI examination of the right calf. Echo planar imaging sequence was performed at rest, during dorsal flexion and during plantar flexion. The three eigenvalues ({lambda}1, {lambda}2, and {lambda}3), apparent diffusion coefficient (ADC) and fractional anisotropy (FA) of the diffusion tensor were calculated for medial gastrocnemius (mGM) and tibialis anterior (TA). A fiber tractography was performed on both muscles. Non-parametric Wilcoxon and Mann Whitney tests were used for statistical evaluation. At rest, {lambda}1, {lambda}2 and ADC of mGM were higher than their counterparts of TA (P < 0.01). During dorsal flexion, the three eigenvalues and ADC of TA significantly increased (P < 0.05) as their counterparts of mGM slightly decreased (P=NS). Opposite variations were detected during plantar flexion of the foot. Visual analysis evidenced a relationship between 3D representations of MRI fibers and physiological state of muscles. Contraction of calf muscles produces changes in DT parameters, which are related to the physiological state of the muscle. (orig.)

  14. Magnetic resonance imaging of the active second stage of labour: Proof of principle

    International Nuclear Information System (INIS)

    Guettler, F.V.; Heinrich, A.; Rump, J.; Bucourt, M. de; Hamm, B.; Teichgraeber, U.K.; Schnackenburg, B.; Bamberg, C.

    2012-01-01

    To prove that magnetic resonance imaging of foetal anatomy during the active second stage of vaginal delivery is feasible. Initially, five pregnant volunteers around the 30th week of gestation were examined in an open MRI. Based on the findings, one vaginal delivery was acquired under real-time imaging. To monitor the birth status during image acquisition, an MR-compatible wireless cardiotocography (CTG) system was built. Single-shot sequence parameters were optimised to compensate motion artefacts during labour. Safety requirements to monitor the birth process under real-time MR imaging were met. High-resolution MR images were acquired immediately before and after delivery. In one patient, TSE single-shot cinematic sequences of the active second stage of labour were obtained. All sequences were adapted to tolerate movement of the mother and infant, as well as residual noise from the CTG. Furthermore, the MR imaging during labour showed only minor image artefacts. CTG-monitored acquisition of MRI series during the active second stage of delivery is feasible. Image quality should allow various further studies to improve models for birth simulation as well as potential investigation of obstructed labour and obstetric complications. (orig.)

  15. Segmented simultaneous multi-slice diffusion weighted imaging with generalized trajectories.

    Science.gov (United States)

    Herbst, Michael; Deng, Weiran; Ernst, Thomas; Stenger, V Andrew

    2017-10-01

    The purpose of this work is to develop and evaluate a single framework for the use of Cartesian and non-Cartesian segmented trajectories for rapid and robust simultaneous multislice (SMS) diffusion weighted imaging (DWI) at 3 Telsa (T). A generalized SMS approach with intrinsic phase navigation using Multiplexed Sensitivity Encoding (MUSE) was developed. Segmented blipped-controlled aliasing in parallel imaging echo planar imaging (EPI) and z-gradient modulated spiral trajectories were examined using SMS DWI scans at 3T with a 32-channel head coil. The generalized SMS MUSE reconstruction framework was successful in significantly reducing artifacts for all trajectories. A DWI brain volume with a 67.5-mm height, 1.5-mm isotropic resolution, and 90 diffusion weightings was obtained in a scan time of 6 minutes. The MUSE technique can be generalized to allow for reconstruction of both Cartesian and non-Cartesian segmented trajectories. Magn Reson Med 78:1476-1481, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  16. Functional magnetic resonance imaging mapping of the motor cortex in patients with cerebral tumors

    International Nuclear Information System (INIS)

    Mueller, W.M.; Zerrin Yetkin, F.; Hammeke, T.A.

    1997-01-01

    Objective. The purpose of this study was to determine the usefulness of functional magnetic resonance imaging (FMRI) to map cerebral functions in patients with frontal or parietal tumors. Methods. Charts and images of patients with cerebral tumors or vascular malformations who underwent FMRI with an echo-planar technique were reviewed. The FMRI maps of motor (11 patients), tactile sensory (12 patients) and language tasks (4 patients) were obtained. The location of the FMRI activation and the positive responses to intraoperative cortical stimulation were compared. The reliability of the paradigms for mapping the rolandic cortex was evaluated. Results. Rolandic cortex was activated by tactile tasks in hall 12 patients and by motor tasks in 10 of 11 patients. Language tasks elicited activation in each of the four patients. Activation was obtained within edematous brain and adjacent to tumors. FMRI in three cases with intraoperative electro-cortical mapping results showed activation for a language, tactile, or motor task within the same gyrus in which stimulation elicited a related motor, sensory, or language function. In patients with >2 cm between the margin of the tumor, as revealed by magnetic resonance imaging, and the activation, no decline in motor function occurred from surgical resection. Conclusions. FMRI of tactile, motor, and language tasks is feasible in patients with cerebral tumors. FMRI shows promise as a means of determining the risk of a postoperative motor deficit from surgical resection of frontal or parietal tumors. (authors)

  17. Diffusion-weighted imaging of breast tumours at 3 Tesla and 7 Tesla: a comparison

    Energy Technology Data Exchange (ETDEWEB)

    Gruber, S.; Minarikova, L.; Zaric, O.; Chmelik, M.; Strasser, B.; Trattnig, S.; Bogner, W. [Medical University Vienna, MRCE, Department of Biomedical imaging and Image-Guided Therapy, Vienna (Austria); Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna (Austria); Pinker, K.; Baltzer, P.; Helbich, T. [Medical University Vienna, Division of Molecular and Gender Imaging, Department of Biomedical imaging and Image-Guided Therapy, Vienna (Austria)

    2016-05-15

    To compare bilateral diffusion-weighted MR imaging (DWI) at 3 T and 7 T in the same breast tumour patients. Twenty-eight patients were included in this IRB-approved study (mean age 56 ± 16 years). Before contrast-enhanced imaging, bilateral DWI with b = 0 and 850 s/mm{sup 2} was performed in 2:56 min (3 T) and 3:48 min (7 T), using readout-segmented echo planar imaging (rs-EPI) with a 1.4 x 1.4 mm{sup 2} (3 T)/0.9 x 0.9 mm{sup 2} (7 T) in-plane resolution. Apparent diffusion coefficients (ADC), signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were assessed. Twenty-eight lesions were detected (18 malignant, 10 benign). CNR and SNR were comparable at both field strengths (p > 0.3). Mean ADC values at 7 T were 4-22 % lower than at 3 T (p ≤ 0.03). An ADC threshold of 1.275 x 10{sup -3} mm{sup 2}/s resulted in a diagnostic specificity of 90 % at both field strengths. The sensitivity was 94 % and 100 % at 3 T and 7 T, respectively. 7-T DWI of the breast can be performed with 2.4-fold higher spatial resolution than 3 T, without significant differences in SNR if compared to 3 T. (orig.)

  18. Measuring the Temperature Increase of an Ultrasonic Motor in a 3-Tesla Magnetic Resonance Imaging System

    Directory of Open Access Journals (Sweden)

    Peyman Shokrollahi

    2017-06-01

    Full Text Available This paper aims to evaluate the temperature increase caused by a 3.0-T magnetic resonance imaging (MRI system on an ultrasonic motor (USM used to actuate surgical robots in the MRI environment. Four fiber-optic temperature sensors were attached to the USM. Temperature was monitored outside the five-Gauss boundary and then inside the bore for 20 min while the USM was powered on. The USM temperature was tested for two states of the scanner, “off” and “on”, by employing common clinical imaging sequences and echo planar imaging sequences. The USM showed a slight temperature increase while operating in the static field of the MRI. A considerable temperature increase (~10 °C was observed when the scanner was on. The temperature increased to 60 °C, which is beyond the acceptable safe temperature and can result in thermal burns. Most of the temperature increase (80% was due to effects of the static field on the motion of the rotating parts of the motor, while the remainder (20% derived from heat deposited in the conductive components of the USM due to radiofrequency pulses and gradient field changes. To solve the temperature increase, the metal components of the USM’s case can be replaced by silicon carbide.

  19. Diffusion tensor magnetic resonance imaging of the breast: a pilot study

    International Nuclear Information System (INIS)

    Baltzer, Pascal A.T.; Schaefer, Anja; Dietzel, Matthias; Kaiser, Werner A.; Graessel, David; Gajda, Mieczyslaw; Camara, Oumar

    2011-01-01

    Diffusion-weighted MR imaging has shown diagnostic value for differential diagnosis of breast lesions. Diffusion tensor imaging (DTI) adds information about tissue microstructure by addressing diffusion direction. We have examined the diagnostic application of DTI of the breast. A total of 59 patients (71 lesions: 54 malignant, 17 benign) successfully underwent prospective echo planar imaging-DTI (EPI-DTI) (1.5 T). First, diffusion direction both of parenchyma as well as lesions was assessed on parametric maps. Subsequently, apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values were measured. Statistics included univariate (Mann-Whitney U test, receiver operating analysis) and multivariate (logistic regression analysis, LRA) tests. Main diffusion direction of parenchyma was anterior-posterior in the majority of cases (66.1%), whereas lesions (benign, malignant) showed no predominant diffusion direction in the majority of cases (23.9%). ADC values showed highest differences between benign and malignant lesions (P < 0.001) with resulting area under the curve (AUC) of 0.899. FA values were lower in benign (interquartile range, IR, 0.14-0.24) compared to malignant lesions (IR 0.21-0.35, P < 0.002) with an AUC of 0.751-0.770. Following LRA, FA did not prove to have incremental value for differential diagnosis over ADC values. Microanatomical differences between benign and malignant breast lesions as well as breast parenchyma can be visualized by using DTI. (orig.)

  20. Increased self-diffusion of brain water in hydrocephalus measured by MR imaging

    International Nuclear Information System (INIS)

    Gideon, P.; Thomsen, C.; Gjerris, F.; Soerensen, P.S.; Henriksen, O.

    1994-01-01

    We used MR imaging to measure the apparent brain water self-diffusion in 5 patients with normal pressure hydrocephalus (NPH), in 2 patients with high pressure hydrocephalus (HPH), and in 8 agematched controls. In all patients with NPH significant elevations of the apparent diffusion coefficients (ADC) of brain water were found within periventricular white matter, in the corpus callosum, in the internal capsule, within cortical gray matter, and in cerebrospinal fluid, whereas normal ADCs were found within the basal ganglia. In 2 patients with HPH elevated ADCs were found most prominently within white matter and in one patient reexamined one year after surgery. ADCs were unchanged in nearly all brain regions. The increased ADC values in hydrocephalus patients may be caused by factors such as changes in myelin-associated bound water, increased Virchow-Robin spaces, and increased extracellular brain water fraction. For further studies of brain water diffusion in hydrocephalus patients, echo-planar imaging techniques with imaging times of a few seconds may be valuable. (orig.)

  1. Fourier component imaging of water resonance in the human breast provides markers for malignancy

    Science.gov (United States)

    Medved, Milica; Newstead, Gillian M.; Fan, Xiaobing; Du, Yiping P.; Olopade, Olufunmilayo I.; Shimauchi, Akiko; Zamora, Marta A.; Karczmar, Gregory S.

    2009-10-01

    The purpose of this paper is to demonstrate that voxels with inhomogeneously broadened water resonances, as revealed by high spectral and spatial resolution (HiSS) MRI, correlate with underlying tumor pathology findings, and thus carry diagnostically useful information. Thirty-four women with mammographically suspicious breast lesions were imaged at 1.5 T, using high-resolution echo-planar spectroscopic imaging. Fourier component images (FCIs) of the off-peak spectral signal were generated, and clusters of voxels with significant inhomogeneous broadening (broadened clusters) were identified and correlated to biopsy results. Inhomogeneously broadened clusters were found significantly more frequently in malignant than in benign lesions. A larger percentage of broadened cluster voxels were found inside the malignant versus benign lesions. The high statistical significance for separation of benign and malignant lesions was robust over a large range of post-processing parameters, with a maximum ROC area under curve of 0.83. In the human breast, an inhomogeneously broadened water resonance can serve as a correlate marker for malignancy and is likely to reflect the underlying anatomy or physiology.

  2. Preliminary clinical applications of DTI in human cervical spinal cord

    International Nuclear Information System (INIS)

    Song Ting; Mai Weiwen; Liang Biling; Shen Jun; Huang Suiqiao; Hu Chunhong

    2007-01-01

    Objective: To condcut preliminary study of the value of DTI(diffusion tensor imaging) in human cervical spinal cord. Methods: Twenty-one patients suffering from cervical spondylotic myelopathy and twenty volunteers without any clinical symptoms underwent routine MRI and DTI examination. DTI was performed in six non-collinear directions with single-shot fast spin echo echo, planar imaging sequence(b value = 400 s·mm -2 ). ADC(apparent diffusion coefficient) and FA(fractional anisotropy)values were measured by ROIs(regions of interest) in 4 different level segment spinal cord (C 2/3 , C 3/4 , C 4/5 , C 5/6 ) in normal volunteers, in lesions and normal segmental spinal cord in clinical cases respectively. DTI original images were automatically processed by using IDL (Version 5.6) soft- ware to produce color tensor images. SPSS11.0 software for windows was used for t-test and one-way ANOVA analysis. The difference was considered statistically significant if P 2/3 , C 3/4 , C 4/5 , C 5/6 , were analyzed and it was found that FA value between them had a significant difference by ANOVA, F=159.24, P 2/3 level. However, ADC value between 4 segments had no significant difference(F=2.191, P>0.05). (2)In patients of cervical spondylotic myelopathy, routine MRI T2WI showed abnormal signal in 9 cases, and showed no abnormal signal in 12 dases. In sixteen cases it was found that abnormal patchy green signal on colorized tensor maps appeared on the normal blue spinal cord. Also, in patients of cervical spondylotic myelopathy, there was significant difference in ADC and FA value between lesions and normal spinal cord (paired t test, for ADC, t=2.88, P 2/3 level segment spinal cord in normal volunteers (0.85 ± 0.03) is the highest among other segments. FA value decreases gradually along cervical spinal cord towards the caudal direction. However, the difference of ADC values amongst 4 segments is not significant. DTI colorized tensor maps can show more lesions than routine MRI

  3. Multiband diffusion-weighted MRI of the eye and orbit free of geometric distortions using a RARE-EPI hybrid.

    Science.gov (United States)

    Paul, Katharina; Huelnhagen, Till; Oberacker, Eva; Wenz, Daniel; Kuehne, André; Waiczies, Helmar; Schmitter, Sebastian; Stachs, Oliver; Niendorf, Thoralf

    2018-03-01

    Diffusion-weighted imaging (DWI) provides information on tissue microstructure. Single-shot echo planar imaging (EPI) is the most common technique for DWI applications in the brain, but is prone to geometric distortions and signal voids. Rapid acquisition with relaxation enhancement [RARE, also known as fast spin echo (FSE)] imaging presents a valuable alternative to DWI with high anatomical accuracy. This work proposes a multi-shot diffusion-weighted RARE-EPI hybrid pulse sequence, combining the anatomical integrity of RARE with the imaging speed and radiofrequency (RF) power deposition advantage of EPI. The anatomical integrity of RARE-EPI was demonstrated and quantified by center of gravity analysis for both morphological images and diffusion-weighted acquisitions in phantom and in vivo experiments at 3.0 T and 7.0 T. The results indicate that half of the RARE echoes in the echo train can be replaced by EPI echoes whilst maintaining anatomical accuracy. The reduced RF power deposition of RARE-EPI enabled multiband RF pulses facilitating simultaneous multi-slice imaging. This study shows that diffusion-weighted RARE-EPI has the capability to acquire high fidelity, distortion-free images of the eye and the orbit. It is shown that RARE-EPI maintains the immunity to B 0 inhomogeneities reported for RARE imaging. This benefit can be exploited for the assessment of ocular masses and pathological changes of the eye and the orbit. Copyright © 2018 John Wiley & Sons, Ltd.

  4. Combination of chemical suppression techniques for dual suppression of fat and silicone at diffusion-weighted MR imaging in women with breast implants

    International Nuclear Information System (INIS)

    Koh, Dow-Mu; Hughes, J.; Blackledge, M.; Leach, M.O.; Collins, D.J.; Burns, S.; Stemmer, A.; Kiefer, B.

    2012-01-01

    Silicone breast prostheses prove technically challenging when performing diffusion-weighted MR imaging in the breasts. We describe a combined fat and chemical suppression scheme to achieve dual suppression of fat and silicone, thereby improving the quality of diffusion-weighted images in women with breast implants. MR imaging was performed at 3.0 and 1.5 T in women with silicone breast implants using short-tau inversion recovery (STIR) fat-suppressed echo-planar (EPI) diffusion-weighted MR imaging (DWI) on its own and combined with the slice-select gradient-reversal (SSGR) technique. Imaging was performed using dedicated breast imaging coils. Complete suppression of the fat and silicone signal was possible at 3.0 T using EPI DWI with STIR and SSGR, evaluated with dedicated breast coils. However, a residual silicone signal was still perceptible at 1.5 T using this combined approach. Nevertheless, a further reduction in silicone signal at 1.5 T could be achieved by employing thinner slice partitions and the addition of the chemical-selective fat-suppression (CHESS) technique. DWI using combined STIR and SSGR chemical suppression techniques is feasible to eliminate or reduce silicone signal from prosthetic breast implants. (orig.)

  5. Brain involvement in patients with inflammatory bowel disease: a voxel-based morphometry and diffusion tensor imaging study.

    Science.gov (United States)

    Zikou, Anastasia K; Kosmidou, Maria; Astrakas, Loukas G; Tzarouchi, Loukia C; Tsianos, Epameinondas; Argyropoulou, Maria I

    2014-10-01

    To investigate structural brain changes in inflammatory bowel disease (IBD). Brain magnetic resonance imaging (MRI) was performed on 18 IBD patients (aged 45.16 ± 14.71 years) and 20 aged-matched control subjects. The imaging protocol consisted of a sagittal-FLAIR, a T1-weighted high-resolution three-dimensional spoiled gradient-echo sequence, and a multisession spin-echo echo-planar diffusion-weighted sequence. Differences between patients and controls in brain volume and diffusion indices were evaluated using the voxel-based morphometry (VBM) and tract-based spatial statistics (TBSS) methods, respectively. The presence of white-matter hyperintensities (WMHIs) was evaluated on FLAIR images. VBM revealed decreased grey matter (GM) volume in patients in the fusiform and the inferior temporal gyrus bilaterally, the right precentral gyrus, the right supplementary motor area, the right middle frontal gyrus and the left superior parietal gyrus (p tensor imaging detects microstructural brain abnormalities in IBD. • Voxel based morphometry reveals brain atrophy in IBD.

  6. Diffusion-weighted MR imaging of intracerebral hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Bo Kiung; Na, Dong Gyu; Ryoo, Jae Wook; Byun, Hong Sik; Roh, Hong Gee; Pyeun, Yong Seon [Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2001-12-01

    To document the signal characteristics of intracerebral hemorrhage (ICH) at evolving stages on diffusion-weighted images (DWI) by comparison with conventional MR images. In our retrospective study, 38 patients with ICH underwent a set of imaging sequences that included DWI, T1-and T2-weighted imaging, and fluid-attenuated inversion recovery (FLAIR). In 33 and 10 patients, respectively, conventional and echo-planar T2 gradient-echo images were also obtained. According to the time interval between symptom onset and initial MRI, five stages were categorized: hyperacute (n=6); acute (n=7); early subacute (n=7); late subacute (n=10); and chronic (n=8). We investigated the signal intensity and apparent diffusion coefficient (ADC) of ICH and compared the signal intensities of hematomas at DWI and on conventional MR images. DWI showed that hematomas were hyperintense at the hyperacute and late subacute stages, and hypointense at the acute, early subacute and chronic stages. Invariably, focal hypointensity was observed within a hyperacute hematoma. At the hyperacute, acute and early subacute stages, hyperintense rims that corresponded with edema surrounding the hematoma were present. The mean ADC ratio was 0.73 at the hyperacute stage, 0.72 at the acute stage, 0.70 at the early subacute stage, 0.72 at the late subacute stage, and 2.56 at the chronic stage. DWI showed that the signal intensity of an ICH may be related to both its ADC value and the magnetic susceptibility effect. In patients with acute stroke, an understanding of the characteristic features of ICH seen at DWI can be helpful in both the characterization of intracranial hemorrhagic lesions and the differentiation of hemorrhage from ischemia.

  7. PROPELLER (periodically rotated overlapping parallel lines with enhanced reconstruction) and EPI diffusion-weighted MR imaging at 3.0 T: pontine magnetic susceptibility artifacts depend on pneumatization of the sphenoid sinus

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Chul Ho; Kim, In Soo [College of Medicine, Keimyung University, Daegu (Korea, Republic of)

    2006-10-15

    In the case of well pneumatized sphenoid sinus, magnetic susceptibility artifact can be visualized at the brainstem and especially at the pons on echo-planar imaging (EPI) diffusion-weighted imaging. Fast spin-echo periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) is a novel imaging method that can reduce these artifacts. In 3.0 T MR, we first evaluate the degree of the relationship of pneumatization of the sphenoid sinus with the occurrence of magnetic susceptibility artifacts (MSA) on the echo planar imaging (EPI) diffusion-weighted imaging (DWI), and we evaluated using PROPELLER-DWI for cancellation of MSAs of the pons in the patients who had MSAs on the EPI-DWI. Sixty subjects (mean age: 58 years old and there were 30 men) who were classified according to the two types of sphenoid sinus underwent EPI-DWI. The two types of sphenoid sinus were classified by the degree of pneumatization on the sagittal T2-weighted image. The type-1 sphenoid sinus was 0% to less than 50% aeration of the bony sellar floor, and type-2 was 50% or more aeration of the boney sellar floor. Each of 10 subjects (n = 20/60, mean age: 53) of the two types had PROPELLER and EPI-DWI performed simultaneously. We first evaluated the absence or presence of MSAs at the pons in the two types, and we compared EPI and PROPELLER-DWI in the subjects who underwent the two MR sequences simultaneously. We used 3.0 T MR (Signa VHi, GE, MW, U.S.A.) with a standard head coil. All the MR images were interpreted by one neuroradiologiest. For the type-1, two (6.7%) cases had MSAs and 28 (93.7%) cases did not have MSAs on the EPI-DWI. For the type-2, twenty-seven (90%) cases had MSAs and 3 (10%) cases did not have MSAs on the EPI-DWI. The degree of pneumatization of the sphenoid sinus was related with the occurrence of MSAs of the pons, according to the chi-square test ({rho} = 0.000). All twenty cases who had PROPELLER-DWI performed had no MASs at the pons regardless of

  8. Detection of fast oscillating magnetic fields using dynamic multiple TR imaging and Fourier analysis.

    Directory of Open Access Journals (Sweden)

    Ki Hwan Kim

    Full Text Available Neuronal oscillations produce oscillating magnetic fields. There have been trials to detect neuronal oscillations using MRI, but the detectability in in vivo is still in debate. Major obstacles to detecting neuronal oscillations are (i weak amplitudes, (ii fast oscillations, which are faster than MRI temporal resolution, and (iii random frequencies and on/off intervals. In this study, we proposed a new approach for direct detection of weak and fast oscillating magnetic fields. The approach consists of (i dynamic acquisitions using multiple times to repeats (TRs and (ii an expanded frequency spectral analysis. Gradient echo echo-planar imaging was used to test the feasibility of the proposed approach with a phantom generating oscillating magnetic fields with various frequencies and amplitudes and random on/off intervals. The results showed that the proposed approach could precisely detect the weak and fast oscillating magnetic fields with random frequencies and on/off intervals. Complex and phase spectra showed reliable signals, while no meaningful signals were observed in magnitude spectra. A two-TR approach provided an absolute frequency spectrum above Nyquist sampling frequency pixel by pixel with no a priori target frequency information. The proposed dynamic multiple-TR imaging and Fourier analysis are promising for direct detection of neuronal oscillations and potentially applicable to any pulse sequences.

  9. Renal water molecular diffusion characteristics in healthy native kidneys: assessment with diffusion tensor MR imaging.

    Directory of Open Access Journals (Sweden)

    Zhenfeng Zheng

    Full Text Available BACKGROUND: To explore the characteristics of diffusion tensor imaging (DTI and magnetic resonance (MR imaging in healthy native kidneys. METHODS: Seventy-three patients without chronic kidney disease underwent DTI-MRI with spin echo-echo planar (SE-EPI sequences accompanied by an array spatial sensitivity encoding technique (ASSET. Cortical and medullary mean, axial and radial diffusivity (MD, AD and RD, fractional anisotropy (FA and primary, secondary and tertiary eigenvalues (λ1, λ2, λ3 were analysed in both kidneys and in different genders. RESULTS: Cortical MD, λ2, λ3, and RD values were higher than corresponding medullary values. The cortical FA value was lower than the medullary FA value. Medullary λ1 and RD values in the left kidney were lower than in the right kidney. Medullary λ2, and λ3 values in women were higher than those in men. Medullary FA values in women were lower than those in men. Medullary FA (r = 0.351, P = 0.002 and λ1 (r = 0.277, P = 0.018 positively correlated with eGFR. Medullary FA (r = -0.25, P = 0.033 negatively correlated with age. CONCLUSIONS: Renal water molecular diffusion differences exist in human kidneys and genders. Age and eGFR correlate with medullary FA and primary eigenvalue.

  10. Diffusion tensor imaging and tractography for assessment of renal allograft dysfunction - initial results

    Energy Technology Data Exchange (ETDEWEB)

    Hueper, Katja; Gutberlet, M.; Rodt, T.; Wacker, F.; Galanski, M.; Hartung, D. [Institute for Diagnostic and Interventional Radiology, Hannover Medical School - Germany, Hannover (Germany); Gwinner, W. [Clinic for Nephrology, Hannover Medical School - Germany, Hannover (Germany); Lehner, F. [Clinic for General, Abdominal and Transplant Surgery, Hannover Medical School - Germany, Hannover (Germany)

    2011-11-15

    To evaluate MR diffusion tensor imaging (DTI) as non-invasive diagnostic tool for detection of acute and chronic allograft dysfunction and changes of organ microstructure. 15 kidney transplanted patients with allograft dysfunction and 14 healthy volunteers were examined using a fat-saturated echo-planar DTI-sequence at 1.5 T (6 diffusion directions, b = 0, 600 s/mm{sup 2}). Mean apparent diffusion coefficient (ADC) and mean fractional anisotropy (FA) were calculated separately for the cortex and for the medulla and compared between healthy and transplanted kidneys. Furthermore, the correlation between diffusion parameters and estimated GFR was determined. The ADC in the cortex and in the medulla were lower in transplanted than in healthy kidneys (p < 0.01). Differences were more distinct for FA, especially in the renal medulla, with a significant reduction in allografts (p < 0.001). Furthermore, in transplanted patients a correlation between mean FA in the medulla and estimated GFR was observed (r = 0.72, p < 0.01). Tractography visualized changes in renal microstructure in patients with impaired allograft function. Changes in allograft function and microstructure can be detected and quantified using DTI. However, to prove the value of DTI for standard clinical application especially correlation of imaging findings and biopsy results is necessary. (orig.)

  11. Functional evaluation of the kidney by diffusion-weighted MR imaging

    International Nuclear Information System (INIS)

    Hasegawa, Taro; Hasegawa, Norio; Irie, Takeo; Fukuda, Kunihiko

    2003-01-01

    The purpose of this study was to determine the relationship between the apparent diffusion coefficient (ADC) and diffuse renal disease by diffusion-weighted echo planar magnetic resonance (MR) imaging (EPI). Ten volunteers, seven patients with chronic renal failure and eighteen recipients of renal transplants were examined with diffusion-weighted EPI. We compared renal function (serum creatinine level) with provided ADC value. The average ADC values were 2.63 x 10 -3 mm 2 /sec for the whole kidney, 2.67 x 10 -3 mm 2 /sec for the cortex and 2.61 x 10 -3 mm 2 /sec for the medulla in normal kidneys. ADC values in the whole kidney, the cortex and the medulla in chronic renal failure were significantly lower than those for normal kidneys. In renal transplantation kidneys, the ADC values in the cortex were significantly lower than those for normal kidney. There was a linear correlation between ADC value and serum creatinine level. Our results show that diffusion-weighted MR imaging may be useful to identify renal dysfunction. (author)

  12. Detection of fast oscillating magnetic fields using dynamic multiple TR imaging and Fourier analysis.

    Science.gov (United States)

    Kim, Ki Hwan; Heo, Hyo-Im; Park, Sung-Hong

    2018-01-01

    Neuronal oscillations produce oscillating magnetic fields. There have been trials to detect neuronal oscillations using MRI, but the detectability in in vivo is still in debate. Major obstacles to detecting neuronal oscillations are (i) weak amplitudes, (ii) fast oscillations, which are faster than MRI temporal resolution, and (iii) random frequencies and on/off intervals. In this study, we proposed a new approach for direct detection of weak and fast oscillating magnetic fields. The approach consists of (i) dynamic acquisitions using multiple times to repeats (TRs) and (ii) an expanded frequency spectral analysis. Gradient echo echo-planar imaging was used to test the feasibility of the proposed approach with a phantom generating oscillating magnetic fields with various frequencies and amplitudes and random on/off intervals. The results showed that the proposed approach could precisely detect the weak and fast oscillating magnetic fields with random frequencies and on/off intervals. Complex and phase spectra showed reliable signals, while no meaningful signals were observed in magnitude spectra. A two-TR approach provided an absolute frequency spectrum above Nyquist sampling frequency pixel by pixel with no a priori target frequency information. The proposed dynamic multiple-TR imaging and Fourier analysis are promising for direct detection of neuronal oscillations and potentially applicable to any pulse sequences.

  13. Imaging many-body Coulomb interactions and ultrafast photoionization and diffraction with cold atom electron and ion sources

    Science.gov (United States)

    Scholten, Robert; Speirs, Rory; Murphy, Dene; Torrance, Joshua; Thompson, Daniel; Sparkes, Benjamin; McCulloch, Andrew

    2017-04-01

    The CAEIS cold-atom electron/ion source, based on photoionisation of laser cooled atoms, provides a powerful tool for investigating fundamental physical processes. The very low temperature of the ions has allowed us to image intra-beam Coulomb effects with unprecedented detail. With ultrafast laser excitation and streak detection we can probe competing ionization processes, particularly via Rydberg states, including sequential excitation, multiphoton excitation, resonance-enhanced multiphoton excitation and two-color multiphoton excitation. Knowledge from these studies has enabled ultrafast single-shot diffractive electron imaging with atomic resolution using a CAEIS.

  14. Dynamical Nuclear Magnetic Resonance Imaging of Micron-scale Liquids

    Science.gov (United States)

    Sixta, Aimee; Choate, Alexandra; Maeker, Jake; Bogat, Sophia; Tennant, Daniel; Mozaffari, Shirin; Markert, John

    We report our efforts in the development of Nuclear Magnetic Resonance Force Microscopy (NMRFM) for dynamical imaging of liquid media at the micron scale. Our probe contains microfluidic samples sealed in thin-walled (µm) quartz tubes, with a micro-oscillator sensor nearby in vacuum to maintain its high mechanical resonance quality factor. Using 10 µm spherical permalloy magnets at the oscillator tips, a 3D T1-resolved image of spin density can be obtained by reconstruction from our magnetostatics-modelled resonance slices; as part of this effort, we are exploring single-shot T1 measurements for faster dynamical imaging. We aim to further enhance imaging by using a 2 ω technique to eliminate artifact signals during the cyclic inversion of nuclear spins. The ultimate intent of these efforts is to perform magnetic resonance imaging of individual biological cells.

  15. Parallel imaging enhanced MR colonography using a phantom model.

    LENUS (Irish Health Repository)

    Morrin, Martina M

    2008-09-01

    To compare various Array Spatial and Sensitivity Encoding Technique (ASSET)-enhanced T2W SSFSE (single shot fast spin echo) and T1-weighted (T1W) 3D SPGR (spoiled gradient recalled echo) sequences for polyp detection and image quality at MR colonography (MRC) in a phantom model. Limitations of MRC using standard 3D SPGR T1W imaging include the long breath-hold required to cover the entire colon within one acquisition and the relatively low spatial resolution due to the long acquisition time. Parallel imaging using ASSET-enhanced T2W SSFSE and 3D T1W SPGR imaging results in much shorter imaging times, which allows for increased spatial resolution.

  16. Image Artifacts in Concurrent Transcranial Magnetic Stimulation (TMS) and fMRI Caused by Leakage Currents: Modeling and Compensation

    Science.gov (United States)

    Weiskopf, Nikolaus; Josephs, Oliver; Ruff, Christian C; Blankenburg, Felix; Featherstone, Eric; Thomas, Anthony; Bestmann, Sven; Driver, Jon; Deichmann, Ralf

    2009-01-01

    Purpose To characterize and eliminate a new type of image artifact in concurrent transcranial magnetic stimulation and functional MRI (TMS-fMRI) caused by small leakage currents originating from the high-voltage capacitors in the TMS stimulator system. Materials and Methods The artifacts in echo-planar images (EPI) caused by leakage currents were characterized and quantified in numerical simulations and phantom studies with different phantom-coil geometries. A relay-diode combination was devised and inserted in the TMS circuit that shorts the leakage current. Its effectiveness for artifact reduction was assessed in a phantom scan resembling a realistic TMS-fMRI experiment. Results The leakage-current-induced signal changes exhibited a multipolar spatial pattern and the maxima exceeded 1% at realistic coil-cortex distances. The relay-diode combination effectively reduced the artifact to a negligible level. Conclusion The leakage-current artifacts potentially obscure effects of interest or lead to false-positives. Since the artifact depends on the experimental setup and design (eg, amplitude of the leakage current, coil orientation, paradigm, EPI parameters), we recommend its assessment for each experiment. The relay-diode combination can eliminate the artifacts if necessary. J. Magn. Reson. Imaging 2009;29:1211–1217. © 2009 Wiley-Liss, Inc. PMID:19388099

  17. Correction for Eddy Current-Induced Echo-Shifting Effect in Partial-Fourier Diffusion Tensor Imaging.

    Science.gov (United States)

    Truong, Trong-Kha; Song, Allen W; Chen, Nan-Kuei

    2015-01-01

    In most diffusion tensor imaging (DTI) studies, images are acquired with either a partial-Fourier or a parallel partial-Fourier echo-planar imaging (EPI) sequence, in order to shorten the echo time and increase the signal-to-noise ratio (SNR). However, eddy currents induced by the diffusion-sensitizing gradients can often lead to a shift of the echo in k-space, resulting in three distinct types of artifacts in partial-Fourier DTI. Here, we present an improved DTI acquisition and reconstruction scheme, capable of generating high-quality and high-SNR DTI data without eddy current-induced artifacts. This new scheme consists of three components, respectively, addressing the three distinct types of artifacts. First, a k-space energy-anchored DTI sequence is designed to recover eddy current-induced signal loss (i.e., Type 1 artifact). Second, a multischeme partial-Fourier reconstruction is used to eliminate artificial signal elevation (i.e., Type 2 artifact) associated with the conventional partial-Fourier reconstruction. Third, a signal intensity correction is applied to remove artificial signal modulations due to eddy current-induced erroneous T2(∗) -weighting (i.e., Type 3 artifact). These systematic improvements will greatly increase the consistency and accuracy of DTI measurements, expanding the utility of DTI in translational applications where quantitative robustness is much needed.

  18. Correction for Eddy Current-Induced Echo-Shifting Effect in Partial-Fourier Diffusion Tensor Imaging

    Directory of Open Access Journals (Sweden)

    Trong-Kha Truong

    2015-01-01

    Full Text Available In most diffusion tensor imaging (DTI studies, images are acquired with either a partial-Fourier or a parallel partial-Fourier echo-planar imaging (EPI sequence, in order to shorten the echo time and increase the signal-to-noise ratio (SNR. However, eddy currents induced by the diffusion-sensitizing gradients can often lead to a shift of the echo in k-space, resulting in three distinct types of artifacts in partial-Fourier DTI. Here, we present an improved DTI acquisition and reconstruction scheme, capable of generating high-quality and high-SNR DTI data without eddy current-induced artifacts. This new scheme consists of three components, respectively, addressing the three distinct types of artifacts. First, a k-space energy-anchored DTI sequence is designed to recover eddy current-induced signal loss (i.e., Type 1 artifact. Second, a multischeme partial-Fourier reconstruction is used to eliminate artificial signal elevation (i.e., Type 2 artifact associated with the conventional partial-Fourier reconstruction. Third, a signal intensity correction is applied to remove artificial signal modulations due to eddy current-induced erroneous T2*-weighting (i.e., Type 3 artifact. These systematic improvements will greatly increase the consistency and accuracy of DTI measurements, expanding the utility of DTI in translational applications where quantitative robustness is much needed.

  19. Brain involvement in patients with inflammatory bowel disease: a voxel-based morphometry and diffusion tensor imaging study

    International Nuclear Information System (INIS)

    Zikou, Anastasia K.; Astrakas, Loukas G.; Tzarouchi, Loukia C.; Argyropoulou, Maria I.; Kosmidou, Maria; Tsianos, Epameinondas

    2014-01-01

    To investigate structural brain changes in inflammatory bowel disease (IBD). Brain magnetic resonance imaging (MRI) was performed on 18 IBD patients (aged 45.16 ± 14.71 years) and 20 aged-matched control subjects. The imaging protocol consisted of a sagittal-FLAIR, a T1-weighted high-resolution three-dimensional spoiled gradient-echo sequence, and a multisession spin-echo echo-planar diffusion-weighted sequence. Differences between patients and controls in brain volume and diffusion indices were evaluated using the voxel-based morphometry (VBM) and tract-based spatial statistics (TBSS) methods, respectively. The presence of white-matter hyperintensities (WMHIs) was evaluated on FLAIR images. VBM revealed decreased grey matter (GM) volume in patients in the fusiform and the inferior temporal gyrus bilaterally, the right precentral gyrus, the right supplementary motor area, the right middle frontal gyrus and the left superior parietal gyrus (p < 0.05). TBSS showed decreased axial diffusivity (AD) in the right corticospinal tract and the right superior longitudinal fasciculus in patients compared with controls. A larger number of WMHIs was observed in patients (p < 0.05). Patients with IBD show an increase in WMHIs and GM atrophy, probably related to cerebral vasculitis and ischaemia. Decreased AD in major white matter tracts could be a secondary phenomenon, representing Wallerian degeneration. (orig.)

  20. Brain involvement in patients with inflammatory bowel disease: a voxel-based morphometry and diffusion tensor imaging study

    Energy Technology Data Exchange (ETDEWEB)

    Zikou, Anastasia K.; Astrakas, Loukas G.; Tzarouchi, Loukia C.; Argyropoulou, Maria I. [University of Ioannina, Department of Radiology, Medical School, Ioannina (Greece); Kosmidou, Maria; Tsianos, Epameinondas [University of Ioannina, 1st Department of Internal Medicine (Hepato-Gastroenterology Unit), Medical School, Ioannina (Greece)

    2014-10-15

    To investigate structural brain changes in inflammatory bowel disease (IBD). Brain magnetic resonance imaging (MRI) was performed on 18 IBD patients (aged 45.16 ± 14.71 years) and 20 aged-matched control subjects. The imaging protocol consisted of a sagittal-FLAIR, a T1-weighted high-resolution three-dimensional spoiled gradient-echo sequence, and a multisession spin-echo echo-planar diffusion-weighted sequence. Differences between patients and controls in brain volume and diffusion indices were evaluated using the voxel-based morphometry (VBM) and tract-based spatial statistics (TBSS) methods, respectively. The presence of white-matter hyperintensities (WMHIs) was evaluated on FLAIR images. VBM revealed decreased grey matter (GM) volume in patients in the fusiform and the inferior temporal gyrus bilaterally, the right precentral gyrus, the right supplementary motor area, the right middle frontal gyrus and the left superior parietal gyrus (p < 0.05). TBSS showed decreased axial diffusivity (AD) in the right corticospinal tract and the right superior longitudinal fasciculus in patients compared with controls. A larger number of WMHIs was observed in patients (p < 0.05). Patients with IBD show an increase in WMHIs and GM atrophy, probably related to cerebral vasculitis and ischaemia. Decreased AD in major white matter tracts could be a secondary phenomenon, representing Wallerian degeneration. (orig.)

  1. Correlation plenoptic imaging

    Science.gov (United States)

    Pepe, Francesco V.; Di Lena, Francesco; Garuccio, Augusto; D'Angelo, Milena

    2017-06-01

    Plenoptic Imaging (PI) is a novel optical technique for achieving tridimensional imaging in a single shot. In conventional PI, a microlens array is inserted in the native image plane and the sensor array is moved behind the microlenses. On the one hand, the microlenses act as imaging pixels to reproduce the image of the scene; on the other hand, each microlens reproduces on the sensor array an image of the camera lens, thus providing the angular information associated with each imaging pixel. The recorded propagation direction is exploited, in post- processing, to computationally retrace the geometrical light path, thus enabling the refocusing of different planes within the scene, the extension of the depth of field of the acquired image, as well as the 3D reconstruction of the scene. However, a trade-off between spatial and angular resolution is built in the standard plenoptic imaging process. We demonstrate that the second-order spatio-temporal correlation properties of light can be exploited to overcome this fundamental limitation. Using two correlated beams, from either a chaotic or an entangled photon source, we can perform imaging in one arm and simultaneously obtain the angular information in the other arm. In fact, we show that the second order correlation function possesses plenoptic imaging properties (i.e., it encodes both spatial and angular information), and is thus characterized by a key re-focusing and 3D imaging capability. From a fundamental standpoint, the plenoptic application is the first situation where the counterintuitive properties of correlated systems are effectively used to beat intrinsic limits of standard imaging systems. From a practical standpoint, our protocol can dramatically enhance the potentials of PI, paving the way towards its promising applications.

  2. Magnetic Resonance Cholangiopancreatography: Image Quality, Ductal Morphology, and Value of Additional T2- and T1-weighted Sequences for the Assessment of Suspected Pancreatic Cancer

    International Nuclear Information System (INIS)

    Lopez Haenninen, E.; Ricke, H.; Amthauer, H.; Roettgen, R.; Boehmig, M.; Langrehr, J.; Pech, M.; Denecke, T.; Rosewicz, S.; Felix, R.

    2005-01-01

    Purpose: To assess image quality and duct morphology on magnetic resonance cholangiopancreatography (MRCP) and also the value of additional T2- and T1-weighted sequences for differentiation of benignity and malignancy in patients with suspected pancreatic tumors. Material and Methods: One-hundred-and-fourteen patients received MRCP and unenhanced and contrast material-enhanced MR imaging. MR results were analyzed independently by two blinded readers, and subsequently correlated with the results from surgery, biopsy, and follow-up. Assessment included the evaluation of image quality, duct visualization and morphology, and the differentiation of pancreatic lesion status (benign versus malignant).Results: Overall, 49 patients had benign final diagnoses, while 65 had a malignant diagnosis. Image quality of single-shot thick-slab MRCP was rated significantly better than the MIP images of multisection MRCP. With MRCP alone, the two readers' accuracy in the assessment of pancreatic lesion status was 72% (95% CI, 64% to 83%) and 69% (95% CI, 56% to 77%), respectively; with the addition of T2- and T1-weighted images the accuracy significantly improved to 89% (95% CI, 82% to 95%) and 84% (95% CI, 77% to 92%) for readers 1 and 2, respectively. Conclusion: Single-shot thick-slab MRCP and multisection MRCP provide complementary results; however, single-shot MRCP had superior image quality. Moreover, assessment of ductal morphology with MRCP alone facilitated the diagnosis of different pathologic conditions of the pancreatobiliary system in the majority of patients. However, with the addition of T2- and T1-weighted sequences the overall diagnostic accuracy was significantly improved and thus we consider that a comprehensive MR approach should comprise both MRCP techniques and parenchymal sequences

  3. High-Resolution X-Ray Lensless Imaging by Differential Holographic Encoding

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Diling [Stanford Univ., CA (United States). Dept. of Applied Physics; SLAC National Accelerator Lab., Menlo Park, CA (United States). Stanford Inst. for Material and Energy Science; Guizar-Sicairos, Manuel [Univ. of Rochester, NY (United States). Inst. of Optics; Wu, Benny [Stanford Univ., CA (United States). Dept. of Applied Physics; SLAC National Accelerator Lab., Menlo Park, CA (United States). Stanford Inst. for Material and Energy Science; Scherz, Andreas [SLAC National Accelerator Lab., Menlo Park, CA (United States). Stanford Inst. for Material and Energy Science; Acremann, Yves [SLAC National Accelerator Lab., Menlo Park, CA (United States). Photon Ultrafast Laser Science and Engineering Inst. (PULSE); Tyliszczak, Tolek [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Advanced Light Source (ALS); Fischer, Peter [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Center for X-ray Optics; Friedenberger, Nina [Universitat Duisburg-Essen (Germany). Dept. of Physics and Center for Nanointegration Duisburg-Essen (CeNIDE); Ollefs, Katharina [Universitat Duisburg-Essen (Germany). Dept. of Physics and Center for Nanointegration Duisburg-Essen (CeNIDE); Farle, Michael [Universitat Duisburg-Essen (Germany). Dept. of Physics and Center for Nanointegration Duisburg-Essen (CeNIDE); Fienup, James R. [Univ. of Rochester, NY (United States). Inst. of Optics; Stöhr, Joachim [SLAC National Accelerator Lab., Menlo Park, CA (United States). Linac Coherent Light Source (LCLS)

    2010-07-01

    X-ray free electron lasers (X-FELs) will soon offer femtosecond pulses of laterally coherent x-rays with sufficient intensity to record single-shot coherent scattering patterns for nanoscale imaging. Pulse trains created by split and- delay techniques even open the door for cinematography on unprecedented nanometer length and femtosecond time scales. A key to real space ultrafast motion pictures is fast and reliable inversion of the recorded reciprocal space scattering patterns. Here we for the first time demonstrate in the x-ray regime the power of a novel technique for lensless high resolution imaging, previously suggested by Guizar-Sicairos and Fienup termed holography with extended reference by autocorrelation linear differential operation, HERALD0. We have achieved superior resolution over conventional x-ray Fourier transform holography (FTH) without sacrifices in SNR or significant increase in algorithmic complexity. By combining images obtained from individual sharp features on an extended reference, we further show that the resolution can be even extended beyond the reference fabrication limits. Direct comparison to iterative phase retrieval image reconstruction and images recorded with state of-the-art zone plate microscopes is presented. Our results demonstrate the power of HERALDO as a favorable candidate for robust inversion of single-shot coherent scattering patterns.

  4. High resolution x-ray lensless imaging by differential holographic encoding

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, D.; Guizar-Sicairos, M.; Wu, B.; Scherz, A.; Acremann, Y.; Tylisczcak, T.; Fischer, P.; Friedenberger, N.; Ollefs, K.; Farle, M.; Fienup, J. R.; Stohr, J.

    2009-11-02

    X-ray free electron lasers (X-FEL{sub s}) will soon offer femtosecond pulses of laterally coherent x-rays with sufficient intensity to record single-shot coherent scattering patterns for nanoscale imaging. Pulse trains created by splitand-delay techniques even open the door for cinematography on unprecedented nanometer length and femtosecond time scales. A key to real space ultrafast motion pictures is fast and reliable inversion of the recorded reciprocal space scattering patterns. Here we for the first time demonstrate in the x-ray regime the power of a novel technique for lensless high resolution imaging, previously suggested by Guizar-Sicairos and Fienup termed holography with extended reference by autocorrelation linear differential operation, HERALD0. We have achieved superior resolution over conventional x-ray Fourier transform holography (FTH) without sacrifices in SNR or significant increase in algorithmic complexity. By combining images obtained from individual sharp features on an extended reference, we further show that the resolution can be even extended beyond the reference fabrication limits. Direct comparison to iterative phase retrieval image reconstruction and images recorded with stateof- the-art zone plate microscopes is presented. Our results demonstrate the power of HERALDO as a favorable candidate for robust inversion of single-shot coherent scattering patterns.

  5. Initial experience of oculodynamic MRI using ultrafast T2-weighted imaging

    International Nuclear Information System (INIS)

    Tanitame, Keizo; Kaichi, Yoko; Nakamura, Yuko

    2013-01-01

    We designed cine MRI protocol using sequential static half-Fourier single-shot rapid acquisition with relaxation enhancement (RARE) images with the subjects staring at the series of targets in front of their eyes. This technique was applied to three healthy volunteers and four patients with ocular motility disorders, including blow-out fracture, globe restriction due to a large posterior staphyloma, neurogenic strabismus (convergence disorder), and intraocular adhesion. In the volunteers, smooth movements of their visual foci and extraocular muscles were observed. In the patients, the ocular movement disturbances were demonstrated. Oculodynamic MRI provides functional information in cases of diplopia. (author)

  6. The imaging of intussusception

    International Nuclear Information System (INIS)

    Byrne, A.T.; Goeghegan, T.; Govender, P.; Lyburn, I.D.; Colhoun, E.; Torreggiani, W.C.

    2005-01-01

    Intussusception is defined as the telescoping of one segment of the gastrointestinal tract into an adjacent one. It is relatively common in children and is the second most common cause of an acute abdomen in this age group. It is much less common in adults and accounts for less than 5% of cases of mechanical small bowel obstruction. Whereas the diagnosis is usually already suspected in children before imaging, it is often made unexpectedly in adults. In addition, although in children there is usually no specific underlying cause, an underlying lead point is often present in adults. Plain film radiography, barium studies and ultrasound imaging play major roles in both the diagnosis and management of this condition, and it is increasingly common for the diagnosis to be made by CT and MRI, particularly in adults. This pictorial essay reviews the imaging features that may be found in patients with bowel intussusception. As well as describing the imaging features of the more commonly used tests, we also stress the role of emerging technologies such as MRI using ultrafast half-fourier sequences with single shot turbo spin echo

  7. The imaging of intussusception

    Energy Technology Data Exchange (ETDEWEB)

    Byrne, A.T. [Adelaide and Meath Incorporating the National Children' s Hospital, Dublin, Eire (Ireland)]. E-mail: angelabyrenx@hotmail.com; Goeghegan, T. [Adelaide and Meath Incorporating the National Children' s Hospital, Dublin, Eire (Ireland); Govender, P. [Adelaide and Meath Incorporating the National Children' s Hospital, Dublin, Eire (Ireland); Lyburn, I.D. [Department of Radiology, Frenchay Hospital, Bristol (United Kingdom); Colhoun, E. [Adelaide and Meath Incorporating the National Children' s Hospital, Dublin, Eire (Ireland); Torreggiani, W.C. [Adelaide and Meath Incorporating the National Children' s Hospital, Dublin, Eire (Ireland)]. E-mail: william.torreggiani@amnch.ie

    2005-01-01

    Intussusception is defined as the telescoping of one segment of the gastrointestinal tract into an adjacent one. It is relatively common in children and is the second most common cause of an acute abdomen in this age group. It is much less common in adults and accounts for less than 5% of cases of mechanical small bowel obstruction. Whereas the diagnosis is usually already suspected in children before imaging, it is often made unexpectedly in adults. In addition, although in children there is usually no specific underlying cause, an underlying lead point is often present in adults. Plain film radiography, barium studies and ultrasound imaging play major roles in both the diagnosis and management of this condition, and it is increasingly common for the diagnosis to be made by CT and MRI, particularly in adults. This pictorial essay reviews the imaging features that may be found in patients with bowel intussusception. As well as describing the imaging features of the more commonly used tests, we also stress the role of emerging technologies such as MRI using ultrafast half-fourier sequences with single shot turbo spin echo.

  8. Spatial functional distribution in the corticospinal tract at the corona radiata. A three-dimensional anisotropy contrast study

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Takashi; Yoshimoto, Takashi [Tohoku Univ., Sendai (Japan). School of Medicine; Shimizu, Hiroaki; Kabasawa, Hiroyuki

    2001-06-01

    The spatial functional distribution of the nerve fibers was investigated in the corticospinal tract at the level of the corona radiata. Thirteen patients with corona radiata infarction underwent axial single-shot echo planar diffusion-weighted magnetic resonance imaging using a 1.5 Tesla scanner. Image analysis used the three-dimensional anisotropy contrast (3DAC) method to demarcate the nerve fibers in the corticospinal tract. Axial 3DAC images demonstrated the corticospinal tract as a distinct area indicating nerve fiber integrity in all normal hemispheres and infraction as a dark or black area in affected hemispheres. Seven patients with upper extremity-dominant motor dysfunction had infarction located in the middle one third of the corticospinal tract. A patient with lower extremity-dominant motor dysfunction had infarction in the posterior one third. Five patients with equal motor dysfunction in the upper and lower extremities had infarction in both the middle and posterior one thirds of the corticospinal tract. The recovery of motor dysfunction at one month follow up correlated with the location of the corticospinal; tract injury on the initial 3DAC images. The findings of the 3DAC images provide an indicator of the pattern and the recovery from acute and chronic motor dysfunction in patients with corona radiata infarction. (author)

  9. Diffusion MR imaging with PSIF and SPLICE. Experiences in phantom studies and the central nervous system

    International Nuclear Information System (INIS)

    Uchikoshi, Masato; Ueda, Takashi; Kaji, Yasushi

    2001-01-01

    Studies have shown that diffusion MR imaging is a reliable method for the diagnosis of central nervous system diseases, especially acute cerebral infarction. Although echo planar imaging (EPI) is a promising tool for that purpose, it is vulnerable to susceptibility artifacts that are responsible for image distortion or signal loss. Our purpose in this study was to evaluate the usefulness of diffusion MR imaging with PSIF (reversed fast imaging SSFP) and split acquisition of fast-spin-echo signals for diffusion imaging (SPLICE) in the central nervous system (CNS). First, PSIF and SPLICE were applied to the phantoms. Each phantom, including acetone, acetic acid, and water, was analyzed for apparent diffusion coefficient (ADC) based on SPLICE and for diffusion-related coefficient (DRC) based on PSIF. The ADCs based on SPLICE were 4.36±0.89 x 10 -3 mm 2 /sec, 1.25±0.04 x 10 -3 mm 2 /sec, and 2.35±0.04 x 10 -3 mm 2 /sec, and the DRCs based on PSIF were 0.353±0.25, 0.178±0.07, and 0.273±0.018 for acetone, acetic acid, and water, respectively. These calculated ADCs based on SPLICE were well correlated with known diffusion coefficients, showing a correlation coefficient of 0.995. Second, PSIF and SPLICE were applied to the CNS. The advantage of PSIF and SPLICE was that susceptibility artifacts were reduced in the images of spinal cord and brain stem. PSIF was especially useful for diffusion MR imaging in the spinal cord. The disadvantage of SPLICE was the decreased SN ratio. We conclude that PSIF or SPLICE may be helpful when EPI diffusion MR imaging is insufficient. (author)

  10. Feasibility of diffusion tensor imaging (DTI) with fibre tractography of the normal female pelvic floor

    International Nuclear Information System (INIS)

    Zijta, F.M.; Froeling, M.; Paardt, M.P. van der; Bipat, S.; Nederveen, A.J.; Stoker, J.; Lakeman, M.M.E.; Montauban van Swijndregt, A.D.; Strijkers, G.J.

    2011-01-01

    To prospectively determine the feasibility of diffusion tensor imaging (DTI) with fibre tractography as a tool for the three-dimensional (3D) visualisation of normal pelvic floor anatomy. Five young female nulliparous subjects (mean age 28 ± 3 years) underwent DTI at 3.0T. Two-dimensional diffusion-weighted axial spin-echo echo-planar (SP-EPI) pulse sequence of the pelvic floor was performed, with additional T2-TSE multiplanar sequences for anatomical reference. Fibre tractography for visualisation of predefined pelvic floor and pelvic wall muscles was performed offline by two observers, applying a consensus method. Three eigenvalues (λ1, λ2, λ3), fractional anisotropy (FA) and mean diffusivity (MD) were calculated from the fibre trajectories. In all subjects fibre tractography resulted in a satisfactory anatomical representation of the pubovisceral muscle, perineal body, anal - and urethral sphincter complex and internal obturator muscle. Mean FA values ranged from 0.23 ± 0.02 to 0.30 ± 0.04, MD values from 1.30 ± 0.08 to 1.73 ± 0.12 x 10- 3 mm 2 /s. Muscular structures in the superficial layer of the pelvic floor could not be satisfactorily identified. This study demonstrates the feasibility of visualising the complex three-dimensional pelvic floor architecture using 3T-DTI with fibre tractography. DTI of the deep female pelvic floor may provide new insights into pelvic floor disorders. (orig.)

  11. Feasibility of diffusion tensor imaging (DTI) with fibre tractography of the normal female pelvic floor

    Energy Technology Data Exchange (ETDEWEB)

    Zijta, F.M. [University of Amsterdam, Department of Radiology, Academic Medical Center, Amsterdam (Netherlands); Onze Lieve Vrouwe Gasthuis, Department of Radiology, Amsterdam (Netherlands); Froeling, M. [University of Amsterdam, Department of Radiology, Academic Medical Center, Amsterdam (Netherlands); Eindhoven University of Technology, Biomedical NMR, Department of Biomedical Engineering, Eindhoven (Netherlands); Paardt, M.P. van der; Bipat, S.; Nederveen, A.J.; Stoker, J. [University of Amsterdam, Department of Radiology, Academic Medical Center, Amsterdam (Netherlands); Lakeman, M.M.E. [University of Amsterdam, Department of Gynaecology, Academic Medical Center, Amsterdam (Netherlands); Montauban van Swijndregt, A.D. [Onze Lieve Vrouwe Gasthuis, Department of Radiology, Amsterdam (Netherlands); Strijkers, G.J. [Eindhoven University of Technology, Biomedical NMR, Department of Biomedical Engineering, Eindhoven (Netherlands)

    2011-06-15

    To prospectively determine the feasibility of diffusion tensor imaging (DTI) with fibre tractography as a tool for the three-dimensional (3D) visualisation of normal pelvic floor anatomy. Five young female nulliparous subjects (mean age 28 {+-} 3 years) underwent DTI at 3.0T. Two-dimensional diffusion-weighted axial spin-echo echo-planar (SP-EPI) pulse sequence of the pelvic floor was performed, with additional T2-TSE multiplanar sequences for anatomical reference. Fibre tractography for visualisation of predefined pelvic floor and pelvic wall muscles was performed offline by two observers, applying a consensus method. Three eigenvalues ({lambda}1, {lambda}2, {lambda}3), fractional anisotropy (FA) and mean diffusivity (MD) were calculated from the fibre trajectories. In all subjects fibre tractography resulted in a satisfactory anatomical representation of the pubovisceral muscle, perineal body, anal - and urethral sphincter complex and internal obturator muscle. Mean FA values ranged from 0.23 {+-} 0.02 to 0.30 {+-} 0.04, MD values from 1.30 {+-} 0.08 to 1.73 {+-} 0.12 x 10-{sup 3} mm{sup 2}/s. Muscular structures in the superficial layer of the pelvic floor could not be satisfactorily identified. This study demonstrates the feasibility of visualising the complex three-dimensional pelvic floor architecture using 3T-DTI with fibre tractography. DTI of the deep female pelvic floor may provide new insights into pelvic floor disorders. (orig.)

  12. MR diffusion weighted imaging of the prostate adenocarcinoma after endocrinotherapy: preliminary results

    International Nuclear Information System (INIS)

    Chen Zhiqiang; Wang Xiaoying; Li Feiyu; Guo Xuemei; Jiang Xuexiang; Guo Yulin

    2007-01-01

    Objective: To assess the changes of the apparent diffusion coefficient (ADC) values of cancerous and noncancerous regions of prostate peripheral zone in prostate cancer patients with and without endocrinotherapy. Methods: Diffusion-weighted echo-planar imaging (EPI) were performed in 32 patients with diagnosed prostate cancer, including 18 patients who were treated with endocrinotherapy over 6 months and 14 untreated matched control patients. According to the pathological results obtained by ultrasound guided biopsy, the locations of the prostate cancerous regions were marked at one or more of the sextants. The ADC values of the bladder and the obturator internus were also measured. Results: The mean ADC values of cancerous and noncancerous regions in 14 untreated controls were (1.22±0.25) x 10 -3 , (1.59 ± 0.19) x 10 -3 mm 2 /s, respectively (t=7.03, P -3 mm 2 /s in noncancerous regions, but increased to (1.46 ± 0.30) x 10 -3 mm 2 /s in cancerous regions. There still had significant difference between the cancerous and the noncancerous regions (t=2.46, P 0.05), in bladder and the obturator internus (t=0.48, 1.64; P>0.05). Conclusion: Measurement of ADCs might be useful to evaluate the efficacy of endocrinotherapy for patients with prostate cancer. (authors)

  13. Image artifacts in concurrent transcranial magnetic stimulation (TMS) and fMRI caused by leakage currents: modeling and compensation.

    Science.gov (United States)

    Weiskopf, Nikolaus; Josephs, Oliver; Ruff, Christian C; Blankenburg, Felix; Featherstone, Eric; Thomas, Anthony; Bestmann, Sven; Driver, Jon; Deichmann, Ralf

    2009-05-01

    To characterize and eliminate a new type of image artifact in concurrent transcranial magnetic stimulation and functional MRI (TMS-fMRI) caused by small leakage currents originating from the high-voltage capacitors in the TMS stimulator system. The artifacts in echo-planar images (EPI) caused by leakage currents were characterized and quantified in numerical simulations and phantom studies with different phantom-coil geometries. A relay-diode combination was devised and inserted in the TMS circuit that shorts the leakage current. Its effectiveness for artifact reduction was assessed in a phantom scan resembling a realistic TMS-fMRI experiment. The leakage-current-induced signal changes exhibited a multipolar spatial pattern and the maxima exceeded 1% at realistic coil-cortex distances. The relay-diode combination effectively reduced the artifact to a negligible level. The leakage-current artifacts potentially obscure effects of interest or lead to false-positives. Since the artifact depends on the experimental setup and design (eg, amplitude of the leakage current, coil orientation, paradigm, EPI parameters), we recommend its assessment for each experiment. The relay-diode combination can eliminate the artifacts if necessary.

  14. Diffusion tensor imaging in children with tuberous sclerosis complex: tract-based spatial statistics assessment of brain microstructural changes.

    Science.gov (United States)

    Zikou, Anastasia K; Xydis, Vasileios G; Astrakas, Loukas G; Nakou, Iliada; Tzarouchi, Loukia C; Tzoufi, Meropi; Argyropoulou, Maria I

    2016-07-01

    There is evidence of microstructural changes in normal-appearing white matter of patients with tuberous sclerosis complex. To evaluate major white matter tracts in children with tuberous sclerosis complex using tract-based spatial statistics diffusion tensor imaging (DTI) analysis. Eight children (mean age ± standard deviation: 8.5 ± 5.5 years) with an established diagnosis of tuberous sclerosis complex and 8 age-matched controls were studied. The imaging protocol consisted of T1-weighted high-resolution 3-D spoiled gradient-echo sequence and a spin-echo, echo-planar diffusion-weighted sequence. Differences in the diffusion indices were evaluated using tract-based spatial statistics. Tract-based spatial statistics showed increased axial diffusivity in the children with tuberous sclerosis complex in the superior and anterior corona radiata, the superior longitudinal fascicle, the inferior fronto-occipital fascicle, the uncinate fascicle and the anterior thalamic radiation. No significant differences were observed in fractional anisotropy, mean diffusivity and radial diffusivity between patients and control subjects. No difference was found in the diffusion indices between the baseline and follow-up examination in the patient group. Patients with tuberous sclerosis complex have increased axial diffusivity in major white matter tracts, probably related to reduced axonal integrity.

  15. Large Format Radiographic Imaging

    International Nuclear Information System (INIS)

    Rohrer, J. S.; Stewart, Lacey; Wilke, M. D.; King, N. S.; Baker A, S.; Lewis, Wilfred

    1999-01-01

    Radiographic imaging continues to be a key diagnostic in many areas at Los Alamos National Laboratory (LANL). Radiographic recording systems have taken on many form, from high repetition-rate, gated systems to film recording and storage phosphors. Some systems are designed for synchronization to an accelerator while others may be single shot or may record a frame sequence in a dynamic radiography experiment. While film recording remains a reliable standby in the radiographic community, there is growing interest in investigating electronic recording for many applications. The advantages of real time access to remote data acquisition are highly attractive. Cooled CCD camera systems are capable of providing greater sensitivity with improved signal-to-noise ratio. This paper begins with a review of performance characteristics of the Bechtel Nevada large format imaging system, a gated system capable of viewing scintillators up to 300 mm in diameter. We then examine configuration alternatives in lens coupled and fiber optically coupled electro-optical recording systems. Areas of investigation include tradeoffs between fiber optic and lens coupling, methods of image magnification, and spectral matching from scintillator to CCD camera. Key performance features discussed include field of view, resolution, sensitivity, dynamic range, and system noise characteristics

  16. Diagnostic value of diffusion weighted MRI and ADC in differential ...

    African Journals Online (AJOL)

    –49. 13. Namimoto T, Yamashita Y, Mitsuzaki K, Nakayama. Y, Tang Y, Takahashi M. Measurement of the apparent diffusion coefficient in diffuse renal disease by diffu- sionweighted echo-planar MR imaging. J Magn Reson Im- aging 1999 ...

  17. Apparent diffusion coefficient vale of the brain in patients with Gaucher's disease type II and type III

    International Nuclear Information System (INIS)

    Abdel Razek, Ahmed Abdel Khalek; Abd El-Gaber, Nahed; Abdalla, Ahmed; Fathy, Abeer; Azab, Ahmed; Rahman, Ashraf Abdel

    2009-01-01

    The aim of this work is to assess the usefulness of apparent diffusion coefficient (ADC) value of the brain for diagnosis of patients with Gaucher's disease type II and type III. Prospective study was conducted upon 13 patients (nine boys and four girls aged 8 months-14 years: mean 6.1 years) with Gaucher's disease type II and III and for age-matched control group (n = 13). Diffusion-weighted magnetic resonance imaging using a single-shot echo-planar imaging with a diffusion-weighted factor b of 0, 500, and 1,000 s/mm 2 was done for all patients and volunteers. The ADC value was calculated in ten regions of the brain parenchyma and correlated with genotyping. There was significantly lower ADC value of the cortical frontal (P = 0.003), cortical temporal (P = 0.04), frontal subcortical white matter (P = 0.02), corticospinal tract (P = 0.001), cerebellum (P = 0.001), medulla (P = 0.002), and midbrain (P = 0.02) between patients and volunteers. There was significant difference in the ADC value of the frontal and temporal gray matter (P = 0.04 and 0.05, respectively) between patients with heterozygous and homozygous gene mutation. We concluded that ADC value is a new promising quantitative imaging parameter that can be used for the detection of brain abnormalities in patients with Gaucher's disease type II and type III and has a correlation with genotyping. (orig.)

  18. Multishot diffusion-weighted SPLICE PROPELLER MRI of the abdomen.

    Science.gov (United States)

    Deng, Jie; Omary, Reed A; Larson, Andrew C

    2008-05-01

    Multishot FSE (fast spin echo)-based diffusion-weighted (DW)-PROPELLER (periodically rotated overlapping parallel lines with enhanced reconstruction) MRI offers the potential to reduce susceptibility artifacts associated with single-shot DW-EPI (echo-planar imaging) approaches. However, DW-PROPELLER in the abdomen is challenging due to the large field-of-view and respiratory motion during DW preparation. Incoherent signal phase due to motion will violate the Carr-Purcell-Meiboom-Gill (CPMG) conditions, leading to destructive interference between spin echo and stimulated echo signals and consequent signal cancellation. The SPLICE (split-echo acquisition of FSE signals) technique can mitigate non-CPMG artifacts in FSE-based sequences. For SPLICE, spin echo and stimulated echo are separated by using imbalanced readout gradients and extended acquisition window. Two signal families each with coherent phase properties are acquired at different intervals within the readout window. Separate reconstruction of these two signal families can avoid destructive phase interference. Phantom studies were performed to validate signal phase properties with different initial magnetization phases. This study evaluated the feasibility of combining SPLICE and PROPELLER for DW imaging of the abdomen. It is demonstrated that DW-SPLICE-PROPELLER can effectively mitigate non-CPMG artifacts and improve DW image quality and apparent diffusion coefficient (ADC) map homogeneity. (c) 2008 Wiley-Liss, Inc.

  19. Whole brain white matter changes revealed by multiple diffusion metrics in multiple sclerosis: A TBSS study

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yaou, E-mail: asiaeurope80@gmail.com [Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing 100053 (China); Duan, Yunyun, E-mail: xiaoyun81.love@163.com [Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing 100053 (China); He, Yong, E-mail: yong.h.he@gmail.com [State Key Laboratory of Cognitive Neuroscience and Learning, Beijing Normal University, Beijing 100875 (China); Yu, Chunshui, E-mail: csyuster@gmail.com [Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing 100053 (China); Wang, Jun, E-mail: jun_wang@bnu.edu.cn [State Key Laboratory of Cognitive Neuroscience and Learning, Beijing Normal University, Beijing 100875 (China); Huang, Jing, E-mail: sainthj@126.com [Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing 100053 (China); Ye, Jing, E-mail: jingye.2007@yahoo.com.cn [Department of Neurology, Xuanwu Hospital, Capital Medical University, Beijing 100053 (China); Parizel, Paul M., E-mail: paul.parizel@ua.ac.be [Department of Radiology, Antwerp University Hospital and University of Antwerp, Wilrijkstraat 10, 2650 Edegem, 8 Belgium (Belgium); Li, Kuncheng, E-mail: kunchengli55@gmail.com [Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing 100053 (China); Shu, Ni, E-mail: nshu55@gmail.com [State Key Laboratory of Cognitive Neuroscience and Learning, Beijing Normal University, Beijing 100875 (China)

    2012-10-15

    Objective: To investigate whole brain white matter changes in multiple sclerosis (MS) by multiple diffusion indices, we examined patients with diffusion tensor imaging and utilized tract-based spatial statistics (TBSS) method to analyze the data. Methods: Forty-one relapsing-remitting multiple sclerosis (RRMS) patients and 41 age- and gender-matched normal controls were included in this study. Diffusion weighted images were acquired by employing a single-shot echo planar imaging sequence on a 1.5 T MR scanner. Voxel-wise analyses of multiple diffusion metrics, including fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (AD) and radial diffusivity (RD) were performed with TBSS. Results: The MS patients had significantly decreased FA (9.11%), increased MD (8.26%), AD (3.48%) and RD (13.17%) in their white matter skeletons compared with the controls. Through TBSS analyses, we found abnormal diffusion changes in widespread white matter regions in MS patients. Specifically, decreased FA, increased MD and increased RD were involved in whole-brain white matter, while several regions exhibited increased AD. Furthermore, white matter regions with significant correlations between the diffusion metrics and the clinical variables (the EDSS scores, disease durations and white matter lesion loads) in MS patients were identified. Conclusion: Widespread white matter abnormalities were observed in MS patients revealed by multiple diffusion metrics. The diffusion changes and correlations with clinical variables were mainly attributed to increased RD, implying the predominant role of RD in reflecting the subtle pathological changes in MS.

  20. Residual tumour detection in post-treatment granulation tissue by using advanced diffusion models in head and neck squamous cell carcinoma patients.

    Science.gov (United States)

    Fujima, Noriyuki; Yoshida, Daisuke; Sakashita, Tomohiro; Homma, Akihiro; Kudo, Kohsuke; Shirato, Hiroki

    2017-05-01

    To evaluate the detectability of the residual tumour in post-treatment granulation tissue using parameters obtained with an advanced diffusion model in patients with head and neck squamous cell carcinoma (HNSCC) treated by chemoradiation therapy. We retrospectively evaluated 23 patients with HNSCC after the full course of chemoradiation therapy. The diffusion-weighted image (DWI) acquisition used single-shot spin-echo echo-planar imaging with 11 b-values (0-1000). We calculated 10 DWI parameters using a mono-exponential model, a bi-exponential model, a stretched exponential model (SEM), a diffusion kurtosis imaging (DKI) model and a statistical diffusion model (SDM) in the region of interest (ROI) placed on the post-treatment granulation tissue. The presence of residual tumour was determined by histological findings or clinical follow-up. Among the 23 patients, seven patients were revealed to have residual tumour. The univariate analysis revealed significant differences in six parameters between the patients with and without residual tumour. From the receiver operating characteristic curve analysis, the highest area under curve was detected in the center of the Gaussian distribution of diffusion coefficient (D s ) obtained by the SDM. The multivariate analysis revealed that the D s and diffusion heterogeneity (α) obtained by the SEM were predictors for the presence of residual tumour. DWI parameters obtained by advanced fitting models will be one of the diagnostic tools for the detection of residual tumour. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Whole brain white matter changes revealed by multiple diffusion metrics in multiple sclerosis: A TBSS study

    International Nuclear Information System (INIS)

    Liu, Yaou; Duan, Yunyun; He, Yong; Yu, Chunshui; Wang, Jun; Huang, Jing; Ye, Jing; Parizel, Paul M.; Li, Kuncheng; Shu, Ni

    2012-01-01

    Objective: To investigate whole brain white matter changes in multiple sclerosis (MS) by multiple diffusion indices, we examined patients with diffusion tensor imaging and utilized tract-based spatial statistics (TBSS) method to analyze the data. Methods: Forty-one relapsing-remitting multiple sclerosis (RRMS) patients and 41 age- and gender-matched normal controls were included in this study. Diffusion weighted images were acquired by employing a single-shot echo planar imaging sequence on a 1.5 T MR scanner. Voxel-wise analyses of multiple diffusion metrics, including fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (AD) and radial diffusivity (RD) were performed with TBSS. Results: The MS patients had significantly decreased FA (9.11%), increased MD (8.26%), AD (3.48%) and RD (13.17%) in their white matter skeletons compared with the controls. Through TBSS analyses, we found abnormal diffusion changes in widespread white matter regions in MS patients. Specifically, decreased FA, increased MD and increased RD were involved in whole-brain white matter, while several regions exhibited increased AD. Furthermore, white matter regions with significant correlations between the diffusion metrics and the clinical variables (the EDSS scores, disease durations and white matter lesion loads) in MS patients were identified. Conclusion: Widespread white matter abnormalities were observed in MS patients revealed by multiple diffusion metrics. The diffusion changes and correlations with clinical variables were mainly attributed to increased RD, implying the predominant role of RD in reflecting the subtle pathological changes in MS

  2. Diffusion-weighted imaging features in spinal cord infarction

    International Nuclear Information System (INIS)

    Zhang Jingsong; Huan Yi; Sun Lijun; Chang Yingjuan; Zhao Haitao; Yang Chunmin; Zhang Guangyun

    2005-01-01

    Objective: To analyze the diffusion-weighted MR imaging findings in ischemic spinal cord lesions and discuss the value of diffusion-weighted MR imaging in differentiating diagnosis with inflammatory diseases and tumors. Methods: Six patients (2 male, 4 female) with typical sudden onset of neurological deficits caused by spinal cord ischemia were evaluated. There were no definite etiologies in all patients. DW imaging was performed within 1 to 30 days after the initial neurological symptoms using a Philips Gyroscan 1.5 TMR system. Four patients had other scans including contrast-enhanced MR imaging (CE-MRI) and/or FLAIR scans. Two of them followed up with MR images in three months. All six patients were imaged using a multi-shot, navigator-corrected, echo-planar pulse sequence, and ADC values were calculated in sagittal-oriented plane. Results: MR abnormalities were demonstrated on sagittal T 2 -weighted images with 'patch-like' or 'strip-like' hyperintensities (6/6) and cord enlargement (5/6). Axial T 2 -weighted images showed bilateral (6/6) hyperintensities. In one patient only the posterior spinal artery (PSA) territory was involved. Spinal cord was mainly affected at the cervical (2/6) and thoracolumbar (4/6) region, two of them included the conus medullaris (T10-L1). DW images showed high signals in all infarct lesions, degree of intensity depended on scanning time from ill-onset and progress of illness and whether companied with hemorrhage. In this group, except one case with closely normal ADC value due to one month course of illness, the five others ADC values of lesions calculated from ADC maps arranged from 0.23 x 10 -3 mm 2 /s to 0.47 x 10 -3 mm 2 /s [average value (0.37 ± 0.10) x 10 -3 mm 2 /s], markedly lower than normal parts [ average value (0.89 ± 0.08) x 10 -3 mm 2 /s]. There were marked difference between lesions and normal regions (t=4.71, P 2 W images. Meanwhile, lesions could be displayed much better in DW images than in T 2 W images because

  3. Towards diffractive imaging with single pulses of FEL radiation. Dynamics within irradiatied samples and their influence on the analysis of imaging data

    International Nuclear Information System (INIS)

    Wang, Fenglin

    2010-08-01

    3D single particle coherent diffraction imaging (CDI) of bioparticles (such as proteins, macromolecules and viruses) is one of the main possible applications of the new generation of light sources: free-electron lasers (FELs), which are now available at FLASH (Hamburg, Germany) and LCLS (Stanford, U.S.A.). The extremely bright and ultrashort FEL pulses potentially enable CDI to achieve high resolution down to subnanometer length scale. However, intense FEL pulses cause serious radiation damage in bioparticles, even during single shots, which may set the resolution limits for CDI with FELs. Currently, since the signal-to-noise ratio is very low for small biological particles, direct experimental study of radiation damage in the single particle imaging is fairly difficult. Single atomic (noble gas) clusters become good objects to reveal effects of radiation damage processes on CDI with FEL radiation. This thesis studies three aspects of the radiation damage problem, which are treated in three independent chapters: (1) Molecular Dynamics simulations to quantitively describe radiation damage processes within irradiated atomic clusters during single pulses; (2) reconstruction analysis of single-shot CDI diffraction patterns of atomic clusters, which may potentially help to understand the radiation damage occurring in biological samples; and (3) testing the effects of coating water layers in CDI, which is supposed to minimize the radiation damage in irradiated bioparticles. (orig.)

  4. Towards diffractive imaging with single pulses of FEL radiation. Dynamics within irradiatied samples and their influence on the analysis of imaging data

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Fenglin

    2010-08-15

    3D single particle coherent diffraction imaging (CDI) of bioparticles (such as proteins, macromolecules and viruses) is one of the main possible applications of the new generation of light sources: free-electron lasers (FELs), which are now available at FLASH (Hamburg, Germany) and LCLS (Stanford, U.S.A.). The extremely bright and ultrashort FEL pulses potentially enable CDI to achieve high resolution down to subnanometer length scale. However, intense FEL pulses cause serious radiation damage in bioparticles, even during single shots, which may set the resolution limits for CDI with FELs. Currently, since the signal-to-noise ratio is very low for small biological particles, direct experimental study of radiation damage in the single particle imaging is fairly difficult. Single atomic (noble gas) clusters become good objects to reveal effects of radiation damage processes on CDI with FEL radiation. This thesis studies three aspects of the radiation damage problem, which are treated in three independent chapters: (1) Molecular Dynamics simulations to quantitively describe radiation damage processes within irradiated atomic clusters during single pulses; (2) reconstruction analysis of single-shot CDI diffraction patterns of atomic clusters, which may potentially help to understand the radiation damage occurring in biological samples; and (3) testing the effects of coating water layers in CDI, which is supposed to minimize the radiation damage in irradiated bioparticles. (orig.)

  5. Hyperpolarized13C urea myocardial first-pass perfusion imaging using velocity-selective excitation.

    Science.gov (United States)

    Fuetterer, Maximilian; Busch, Julia; Peereboom, Sophie M; von Deuster, Constantin; Wissmann, Lukas; Lipiski, Miriam; Fleischmann, Thea; Cesarovic, Nikola; Stoeck, Christian T; Kozerke, Sebastian

    2017-06-21

    A velocity-selective binomial excitation scheme for myocardial first-pass perfusion measurements with hyperpolarized 13 C substrates, which preserves bolus magnetization inside the blood pool, is presented. The proposed method is evaluated against gadolinium-enhanced 1 H measurements in-vivo. The proposed excitation with an echo-planar imaging readout was implemented on a clinical CMR system. Dynamic myocardial stress perfusion images were acquired in six healthy pigs after bolus injection of hyperpolarized 13 C urea with the velocity-selective vs. conventional excitation, as well as standard 1 H gadolinium-enhanced images. Signal-to-noise, contrast-to-noise (CNR) and homogeneity of semi-quantitative perfusion measures were compared between methods based on first-pass signal-intensity time curves extracted from a mid-ventricular slice. Diagnostic feasibility is demonstrated in a case of septal infarction. Velocity-selective excitation provides over three-fold reduction in blood pool signal with a two-fold increase in myocardial CNR. Extracted first-pass perfusion curves reveal a significantly reduced variability of semi-quantitative first-pass perfusion measures (12-20%) for velocity-selective excitation compared to conventional excitation (28-93%), comparable to that of reference 1 H gadolinium data (9-15%). Overall image quality appears comparable between the velocity-selective hyperpolarized and gadolinium-enhanced imaging. The feasibility of hyperpolarized 13 C first-pass perfusion CMR has been demonstrated in swine. Comparison with reference 1 H gadolinium data revealed sufficient data quality and indicates the potential of hyperpolarized perfusion imaging for human applications.

  6. Correlation Plenoptic Imaging With Entangled Photons

    Directory of Open Access Journals (Sweden)

    Francesco V. Pepe

    2016-06-01

    Full Text Available Plenoptic imaging is a novel optical technique for three-dimensional imaging in a single shot. It is enabled by the simultaneous measurement of both the location and the propagation direction of light in a given scene. In the standard approach, the maximum spatial and angular resolutions are inversely proportional, and so are the resolution and the maximum achievable depth of focus of the 3D image. We have recently proposed a method to overcome such fundamental limits by combining plenoptic imaging with an intriguing correlation remote-imaging technique: ghost imaging. Here, we theoretically demonstrate that correlation plenoptic imaging can be effectively achieved by exploiting the position-momentum entanglement characterizing spontaneous parametric down-conversion (SPDC photon pairs. As a proof-of-principle demonstration, we shall show that correlation plenoptic imaging with entangled photons may enable the refocusing of an out-of-focus image at the same depth of focus of a standard plenoptic device, but without sacrificing diffraction-limited image resolution.

  7. Voxel-based morphometry and diffusion tensor imaging of the optic pathway in primary open-angle glaucoma: a preliminary study.

    Science.gov (United States)

    Zikou, A K; Kitsos, G; Tzarouchi, L C; Astrakas, L; Alexiou, G A; Argyropoulou, M I

    2012-01-01

    Neuropathologic studies in experimental and human glaucoma have demonstrated degenerative changes in the optic pathway. The purpose of this study was to assess the optic pathway in POAG by using VBM and DTI. Eighteen patients 57.05 ± 11.38 years of age with POAG of 8.30 ± 5.14 years' duration and 18 control subjects underwent a complete ophthalmologic examination, including quantification of the RNFLT by using Stratus OCT 3, and brain imaging. The imaging protocol consisted of a T1-weighted high-resolution 3D spoiled gradient-echo sequence and a multisection spin-echo- planar diffusion-weighted sequence. Data preprocessing and analysis were performed by using Matlab 7.0 and SPM 5. Left temporal and right nasal RNFLTs were significantly thinner than right temporal and left nasal RNFLTs. In patients, VBM revealed a significant reduction in the left visual cortex volume, the left lateral geniculate nucleus, and the intracranial part of the ONs and the chiasma. In addition, a significant decrease of FA was observed in the inferior fronto-occipital fasciculus, the longitudinal and inferior frontal fasciculi, the putamen, the caudate nucleus, the anterior and posterior thalamic radiations, and the anterior and posterior limbs of the internal capsule of the left hemisphere (P < .05). Neurodegenerative changes of the optic pathway and several brain areas associated with the visual system can be observed by using VBM and DTI in patients with POAG, suggesting that glaucoma is a complex neurologic disease.

  8. Images

    Data.gov (United States)

    National Aeronautics and Space Administration — Images for the website main pages and all configurations. The upload and access points for the other images are: Website Template RSW images BSCW Images HIRENASD...

  9. Motor association cortex activity in Parkinson's disease. A functional MRI study

    International Nuclear Information System (INIS)

    Tada, Yukiko

    1998-01-01

    The purpose of this study was to examine the activation of motor association cortex using functional magnetic resonance imaging (fMRI) in patients with Parkinson's disease (PD) and control subjects during performed hand movements. There were 26 patients with PD (12 patients with Hoehn and Yahr stage I-II, 14 patients with stage III) and 8 control subjects. Functional imaging was performed using a 1.5 tesla MRI system equipped with a single-shot, echo-planar pulse sequence. The significant signal changes were observed within the primary sensorimotor area, the supplementary motor area (SMA), and the parietal association area in both PD and control subjects. In PD subjects, the SMA was less activated than in control subjects; there were significant differences in the number of pixels activated in SMA between control and Yahr III group (p<0.01), and between Yahr I-II and Yahr III group (p<0.01). Our results demonstrated that movement related cerebral activity in the SMA is reduced in PD subjects, consistent with previously published data using other methods. It is well known from anatomical studies that one of the major cortical outputs of the basal ganglia is the SMA. This may explain the hypoactivation of the SMA in PD. Studies using fMRI provide a promising method not only for localizing cortical activation related to voluntary movements but also for investigating pathophysiology of movement disorders. (author)

  10. Apparent diffusion coefficient in cervical cancer of the uterus: comparison with the normal uterine cervix

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Sato, Chiho; Ishigaki, Takeo; Kumada, Hisashi; Miura, Shunichi; Takizawa, Osamu

    2005-01-01

    A relation between apparent diffusion coefficient (ADC) values and tumor cellular density has been reported. The purpose of this study was to measure the ADC values of cervical cancers in the uterus and compare them with those of normal cervical tissues, and to test whether ADC could differentiate between normal and malignant cervical tissues in the uterus. Twelve consecutive female patients with cervical cancer of the uterus and ten female patients with other pelvic abnormalities were included in this study. ADC was measured at 1.5 T with b-factors of 0, 300 and 600 s/mm 2 using single-shot echo-planar diffusion-weighted imaging and a parallel imaging technique. The mean ADC value of cervical cancer lesions was 1.09±0.20 x 10 -3 mm 2 /s, and that of normal cervix tissue was 1.79±0.24 x 10 -3 mm 2 /s (P<0.0001). In nine patients treated by chemotherapy and/or radiation therapy, the mean ADC value of the cervical cancer lesion increased significantly after therapy (P<0.001). The present study showed, with a small number of patients, that ADC measurement has a potential ability to differentiate between normal and cancerous tissue in the uterine cervix. Further study is necessary to determine the accuracy of ADC measurement in monitoring the treatment response. (orig.)

  11. Distortion Correction in Fetal EPI Using Non-Rigid Registration With a Laplacian Constraint.

    Science.gov (United States)

    Kuklisova-Murgasova, Maria; Lockwood Estrin, Georgia; Nunes, Rita G; Malik, Shaihan J; Rutherford, Mary A; Rueckert, Daniel; Hajnal, Joseph V

    2018-01-01

    Geometric distortion induced by the main B0 field disrupts the consistency of fetal echo planar imaging (EPI) data, on which diffusion and functional magnetic resonance imaging is based. In this paper, we present a novel data-driven method for simultaneous motion and distortion correction of fetal EPI. A motion-corrected and reconstructed T2 weighted single shot fast spin echo (ssFSE) volume is used as a model of undistorted fetal brain anatomy. Our algorithm interleaves two registration steps: estimation of fetal motion parameters by aligning EPI slices to the model; and deformable registration of EPI slices to slices simulated from the undistorted model to estimate the distortion field. The deformable registration is regularized by a physically inspired Laplacian constraint, to model distortion induced by a source-free background B0 field. Our experiments show that distortion correction significantly improves consistency of reconstructed EPI volumes with ssFSE volumes. In addition, the estimated distortion fields are consistent with fields calculated from acquired field maps, and the Laplacian constraint is essential for estimation of plausible distortion fields. The EPI volumes reconstructed from different scans of the same subject were more consistent when the proposed method was used in comparison with EPI volumes reconstructed from data distortion corrected using a separately acquired B0 field map.

  12. T2* relaxometry of fetal brain at 1.5 Tesla using a motion tolerant method.

    Science.gov (United States)

    Vasylechko, Serge; Malamateniou, Christina; Nunes, Rita G; Fox, Matthew; Allsop, Joanna; Rutherford, Mary; Rueckert, Daniel; Hajnal, Joseph V

    2015-05-01

    The aim of this study was to determine T2* values for the fetal brain in utero and to compare them with previously reported values in preterm and term neonates. Knowledge of T2* may be useful for assessing brain development, brain abnormalities, and for optimizing functional imaging studies. Maternal respiration and unpredictable fetal motion mean that conventional multishot acquisition techniques used in adult T2* relaxometry studies are not practical. Single shot multiecho echo planar imaging was used as a rapid method for measuring fetal T2* by effectively freezing intra-slice motion. T2* determined from a sample of 24 subjects correlated negatively with gestational age with mean values of 220 ms (±45) for frontal white matter, 159 ms (±32) for thalamic gray matter, and 236 ms (±45) for occipital white matter. Fetal T2* values are higher than those previously reported for preterm neonates and decline with a consistent trend across gestational age. The data suggest that longer than usual echo times or direct T2* measurement should be considered when performing fetal fMRI to reach optimal BOLD sensitivity. © 2014 Wiley Periodicals, Inc.

  13. Influence of the language dominant hemisphere on the activation region of the cerebral cortex during mastication

    International Nuclear Information System (INIS)

    Matsushima, Yasuhiko

    2005-01-01

    We used functional magnetic resonance imaging (fMRI) to examine the relationship of the activation region of the cerebral cortex during mastication with the language dominant hemisphere. Twelve healthy subjects were asked to chew a special gum 50 times on each side of the mouth, the gum changed color, becoming a deeper red, as it was chewed. The depth of red of the chewed gum was used to ascertain the habitual masticatory side. Measurements were also performed on a conventional whole body 1.5 T clinical scanner using a single shot, multislice echo-planar imaging sequence. The subjects were asked to masticate first on the right side, and then on the left side. As well, they were instructed to do a shiritori test, which is a word game. Computer analysis of the fMRI was done using statistical parametric mapping (SPM) 99 software (p<0.001, paired t-test). We found that the sensorimotor cortex activated by masticatory movements always contains language dominant hemisphere. (author)

  14. Apparent diffusion coefficient values in peripheral and transition zones of the prostate: comparison between normal and malignant prostatic tissues and correlation with histologic grade.

    Science.gov (United States)

    Tamada, Tsutomu; Sone, Teruki; Jo, Yoshimasa; Toshimitsu, Shinya; Yamashita, Takenori; Yamamoto, Akira; Tanimoto, Daigo; Ito, Katsuyoshi

    2008-09-01

    To investigate the utility of apparent diffusion coefficient (ADC) values for discriminating tumor in patients with prostate cancer from normal prostatic tissues in healthy adult men, and to identify correlations between ADC and histologic grade of prostate cancer. A total of 125 healthy male volunteers (mean age, 60 years; range, 50-86 years) and 90 prostate cancer patients (mean age, 71 years; range, 51-88 years) underwent diffusion-weighted imaging (DWI) of the prostate with a single-shot echo-planar imaging sequence using b-factors of 0 and 800 sec/mm2. ADC was measured from two locations in the peripheral zone (PZ) and two locations in the central gland (CG) in normal subjects, and tumor locations of PZ or transition zone (TZ) in patients with prostate cancer. Mean ADC values of tumor regions in both PZ (1.02+/-0.25x10(-3) mm2/sec) and TZ (0.94+/-0.21x10(-3) mm2/sec) were significantly lower than those in the corresponding normal regions (1.80+/-0.27x10(-3) mm2/sec and 1.34+/-0.14x10(-3) mm2/sec, respectively) (P<0.0001 each). Furthermore, a significant negative correlation was identified between ADC in PZ cancer and tumor Gleason score (rho=-0.497, P<0.0001). ADC values appear to provide acceptable diagnostic accuracy in both PZ and TZ. Copyright (c) 2008 Wiley-Liss, Inc.

  15. Hepatic ADC map as an adjunct to conventional abdominal MRI to evaluate hepatic fibrotic and clinical cirrhotic severity in biliary atresia patients

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Steven Shinn-Forng [National Taiwan University, Department of Medical Imaging, Medical College and Hospital, Taipei (China); Jeng, Yung-Ming [National Taiwan University, Department of Pathology, Medical College and Hospital, Taipei (China); Hsu, Wen-Ming; Ho, Ming-Chih [National Taiwan University, Department of Surgery, Medical College and Hospital, Taipei, Taiwan (China); Yang, Justin Cheng-Ta [National Taiwan University, Department of Medical Imaging, Medical College and Hospital, Taipei (China); National Taiwan University, Institute of Biomedical Engineering, College of Engineering and College of Medicine, Taipei (China)

    2015-10-15

    Hepatic apparent diffusion coefficient (ADC) values and ADC-related indices were correlated with the Mayo risk score for primary biliary cirrhosis (MRSPBC) and METAVIR scores of liver specimens to determine the clinical and pathological significance of diffusion-weighted magnetic resonance imaging (DWMRI). Thirty-two patients with biliary atresia (BA; mean age 461 days, range 11-4616 days) received magnetic resonance examinations from March 2009 to August 2013. A free-breathing DWMRI sequence was performed with the single-shot echo-planar imaging technique with b = 0 and 500 s/mm{sup 2} in all 32 BA patients and 24 controls. We used the ordinal logistic regression test and Spearman rank correlation test to analyse the relationships between the MRSPBC and METAVIR fibrosis scores and right liver-to-psoas ADC ratios (LTPARs). BA patients had significantly lower LTPARs in both hepatic lobes than controls (p < 0.01). Right LTPARs, showing moderate intraobserver agreement (intraclass correlation coefficient = 0.736) and interobserver reliability (intraclass correlation coefficient = 0.659), were negatively correlated with MRSPBC and METAVIR fibrosis scores (R{sup 2} = 0.398, p = 0.024 and R{sup 2} = 0.628, p < 0.001, respectively). Right LTPARs may be used for long-term follow-up of cirrhosis severity in BA patients. (orig.)

  16. Computational multispectral video imaging [Invited

    Science.gov (United States)

    Wang, Peng; Menon, Rajesh

    2018-01-01

    Multi-spectral imagers reveal information unperceivable to humans and conventional cameras. Here, we demonstrate a compact single-shot multi-spectral video-imaging camera by placing a micro-structured diffractive filter in close proximity to the image sensor. The diffractive filter converts spectral information to a spatial code on the sensor pixels. Following a calibration step, this code can be inverted via regularization-based linear algebra, to compute the multi-spectral image. We experimentally demonstrated spectral resolution of 9.6nm within the visible band (430nm to 718nm). We further show that the spatial resolution is enhanced by over 30% compared to the case without the diffractive filter. We also demonstrate Vis-IR imaging with the same sensor. Furthermore, our camera is able to computationally trade-off spectral resolution against the field of view in software without any change in hardware as long as sufficient sensor pixels are utilized for information encoding. Since no absorptive color filters are utilized, sensitivity is preserved as well. Finally, the diffractive filters can be easily manufactured using optical lithography and replication techniques.

  17. Clinical usefulness of diffusion-weighted imaging using low and high b-values to detect rectal cancer

    International Nuclear Information System (INIS)

    Hosonuma, Tomonori; Tozaki, Mitsuhiro; Ichiba, Noriatsu; Sakuma, Tohru; Hayashi, Daichi; Yanaga, Katsuhiko; Fukuda, Kunihiko

    2006-01-01

    The purpose of this study was to assess the potential role of diffusion-weighted imaging (DWI) using low and high b-values to detect rectal cancer. The subjects were 15 patients diagnosed endoscopically with rectal cancer (m in 1 patient, sm in 0, mp in 3, ss in 7, se in 1, a in 3) and 20 patients diagnosed endoscopically with colon cancer and no other lesions (control group). Magnetic resonance imaging was performed using a 1.5T system. DWI was performed in the axial plane using echo planar imaging sequence (repetition time/echo time 1200/66, field of view 306 X 350 mm, reconstruction matrix 156 x 256, pixel size 2.0 x 1.4 x 8.0 mm) and acquired with 2 b-values (50 and 800 s/mm 2 ). Low and high b-value DW images were analyzed visually. A lesion was positive by detection of a focal area of high signal in the rectum in high b-value images. The apparent diffusion coefficient (ADC) values of areas of high signal in high b-value images were calculated from the low and high b-value images. High b-value images enabled visualization of all 15 rectal cancers. In the control group, 13 cases were classified as negative and 7 cases as positive for rectal cancer. Sensitivity for detection of rectal cancer was 100% (15/15), and specificity was 65% (13/20). The mean ADC values in 7 patients with false-positive lesions and in 15 patients with rectal cancer were 1.374 x 10 -3 mm 2 /s (standard deviation [SD]: 0.157) and 1.194 x 10 -3 mm 2 /s (SD: 0.152), respectively (P=0.026). DWI with low and high b-values may be used to screen for rectal cancer. (author)

  18. Prospective motion correction in 2D multishot MRI using EPI navigators and multislice-to-volume image registration.

    Science.gov (United States)

    Hoinkiss, Daniel Christopher; Porter, David Andrew

    2017-12-01

    Prospective motion correction reduces artifacts in MRI by correcting for subject motion in real time, but techniques are limited for multishot 2-dimensional (2D) sequences. This study addresses this limitation by using 2D echo-planar imaging (EPI) slice navigator acquisitions together with a multislice-to-volume image registration. The 2D-EPI navigators were integrated into 2D imaging sequences to allow a rapid, real-time motion correction based on the registration of three navigator slices to a reference volume. A dedicated slice-iteration scheme was used to limit mutual spin-saturation effects between navigator and image data. The method was evaluated using T 2 -weighted spin echo and multishot rapid acquisition with relaxation enhancement (RARE) sequences, and its motion-correction capabilities were compared with those of periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER). Validation was performed in vivo using a well-defined motion protocol. Data acquired during subject motion showed residual motion parameters within ±0.5 mm and ±0.5°, and demonstrated a substantial improvement in image quality compared with uncorrected scans. In a comparison to PROPELLER, the proposed technique preserved a higher level of anatomical detail in the presence of subject motion. EPI-navigator-based prospective motion correction using multislice-to-volume image registration can substantially reduce image artifacts, while minimizing spin-saturation effects. The method can be adapted for use in other 2D MRI sequences and promises to improve image quality in routine clinical examinations. Magn Reson Med 78:2127-2135, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  19. Diffusion-Weighted Imaging Using a Readout-Segmented, Multishot EPI Sequence at 3 T Distinguishes between Morphologically Differentiated and Undifferentiated Subtypes of Thyroid Carcinoma—A Preliminary Study

    Directory of Open Access Journals (Sweden)

    Stefan Schob

    2016-10-01

    Full Text Available BACKGROUND: Thyroid carcinomas represent the most frequent endocrine malignancies. Recent studies were able to distinguish malignant from benign nodules of the thyroid gland with diffusion-weighted imaging (DWI. Although this differentiation is undoubtedly helpful, presurgical discrimination between well-differentiated and undifferentiated carcinomas would be crucial to define the optimal treatment algorithm. Therefore, the aim of this study was to investigate if readout-segmented multishot echo planar DWI is able to differentiate between differentiated and undifferentiated subtypes of thyroid carcinomas. PATIENTS AND METHODS: Fourteen patients with different types of thyroid carcinomas who received preoperative DWI were included in our study. In all lesions, apparent diffusion coefficient (ADCmin, ADCmean, ADCmax, and D were estimated on the basis of region of interest measurements after coregistration with T1-weighted, postcontrast images. All tumors were resected and analyzed histopathologically. Ki-67 index, p53 synthesis, cellularity, and total and average nucleic areas were estimated using ImageJ version 1.48. RESULTS: Analysis of variance revealed a statistically significant difference in ADCmean values between differentiated and undifferentiated thyroid carcinomas (P = .022. Spearman Rho calculation identified significant correlations between ADCmax and cell count (r = 0.541, P = .046 as well as between ADCmax and total nuclei area (r = 0.605, P = .022. CONCLUSION: DWI can distinguish between differentiated and undifferentiated thyroid carcinomas.

  20. Renal zoomed EPI-DWI with spatially-selective radiofrequency excitation pulses in two dimensions

    Energy Technology Data Exchange (ETDEWEB)

    He, Yong-Lan, E-mail: ylhe_526@163.com [Department of Radiology, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing (China); Hausmann, Daniel, E-mail: daniel.hausmann@medma.uni-heidelberg.de [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim – Heidelberg University, Mannheim (Germany); Morelli, John N., E-mail: dr.john.morelli@gmail.com [St. John' s Medical Center, Tulsa, OK (United States); Attenberger, Ulrike I., E-mail: ulrike.attenberger@medma.uni-heidelberg.de [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim – Heidelberg University, Mannheim (Germany); Schoenberg, Stefan O., E-mail: stefan.schoenberg@umm.de [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim – Heidelberg University, Mannheim (Germany); Riffel, Philipp, E-mail: philipp.riffel@umm.de [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim – Heidelberg University, Mannheim (Germany)

    2016-10-15

    Highlights: • Renal zoomed diffusion-weighted imaging with spatially-selective radiofrequency excitation pulses is feasible. • z-EPI offers considerable potential for mitigating the limitations of conventional EPI techniques. • z-EPI of kidney may lead to substantial image quality improvements with reduced artifacts. - Abstract: Purpose: To evaluate the feasibility and clinical robustness of zoomed diffusion-weighted echo planar imaging (z-EPI) relative to conventional single-shot EPI (c-EPI) for DWI of the kidneys. Materials and methods: This retrospective study was approved by the institutional research ethics board. 66 patients (median age 58.5 years ± 13.4, range 23–83 years, 45 men, 21 women) undergoing 3T (Magnetom Skyra{sup ®}, Siemens Healthcare, Erlangen, Germany) using a dynamic parallel transmit array (TimTX TrueShape, Siemens Healthcare, Erlangen, Germany) for renal MRI were included in this study. Both c-EPI and z-EPI images were obtained. For z-EPI, a two-dimensional spatially-selective radiofrequency (RF) pulse was applied for echo planar imaging with the FOV reduced by a factor of 3. Two radiologists, blinded to clinical data and scan parameters evaluated the images with respect to their diagnostic confidence, overall preference, overall image quality, delineation of the kidney, spatial distortion, and image blur. Sequences were compared using a paired Wilcoxon test. ADC values for the upper pole, mid-zone, lower pole of the normal kidneys were compared between sequences as well as ADC values for renal lesions, using a paired t-test. Results: With z-EPI, the kidney was significantly better delineated with sharper boundaries, less image blur and distortion, and overall better image quality relative to c-EPI (all p < 0.001). The z-EPI technique led to greater diagnostic confidence than c-EPI (p = 0.020). z-EPI was preferred to c-EPI in 60 cases (90.9%, 60/66). No statistically significant differences in the ADC values of renal parenchyma or

  1. Renal zoomed EPI-DWI with spatially-selective radiofrequency excitation pulses in two dimensions

    International Nuclear Information System (INIS)

    He, Yong-Lan; Hausmann, Daniel; Morelli, John N.; Attenberger, Ulrike I.; Schoenberg, Stefan O.; Riffel, Philipp

    2016-01-01

    Highlights: • Renal zoomed diffusion-weighted imaging with spatially-selective radiofrequency excitation pulses is feasible. • z-EPI offers considerable potential for mitigating the limitations of conventional EPI techniques. • z-EPI of kidney may lead to substantial image quality improvements with reduced artifacts. - Abstract: Purpose: To evaluate the feasibility and clinical robustness of zoomed diffusion-weighted echo planar imaging (z-EPI) relative to conventional single-shot EPI (c-EPI) for DWI of the kidneys. Materials and methods: This retrospective study was approved by the institutional research ethics board. 66 patients (median age 58.5 years ± 13.4, range 23–83 years, 45 men, 21 women) undergoing 3T (Magnetom Skyra ® , Siemens Healthcare, Erlangen, Germany) using a dynamic parallel transmit array (TimTX TrueShape, Siemens Healthcare, Erlangen, Germany) for renal MRI were included in this study. Both c-EPI and z-EPI images were obtained. For z-EPI, a two-dimensional spatially-selective radiofrequency (RF) pulse was applied for echo planar imaging with the FOV reduced by a factor of 3. Two radiologists, blinded to clinical data and scan parameters evaluated the images with respect to their diagnostic confidence, overall preference, overall image quality, delineation of the kidney, spatial distortion, and image blur. Sequences were compared using a paired Wilcoxon test. ADC values for the upper pole, mid-zone, lower pole of the normal kidneys were compared between sequences as well as ADC values for renal lesions, using a paired t-test. Results: With z-EPI, the kidney was significantly better delineated with sharper boundaries, less image blur and distortion, and overall better image quality relative to c-EPI (all p < 0.001). The z-EPI technique led to greater diagnostic confidence than c-EPI (p = 0.020). z-EPI was preferred to c-EPI in 60 cases (90.9%, 60/66). No statistically significant differences in the ADC values of renal parenchyma or of

  2. Diffusion-weighted MR and apparent diffusion coefficient in the evaluation of severe brain injury

    International Nuclear Information System (INIS)

    Nakahara, M.; Ericson, K.; Bellander, B.M.

    2001-01-01

    Purpose: To study apparent diffusion coefficient (ADC) maps in severely brain-injured patients. Material and Methods: Four deeply comatose patients with severe brain injury were investigated with single-shot, diffusion-weighted, spin-echo echo planar imaging. The tetrahedral diffusion gradient configuration and four iterations of a set of b-values (one time of 0 mm2/s, and four times of 1000 mm2/s) were used to create isotropic ADC maps with high signal-to-noise ratio. ADC values of gray and white matter were compared among patients and 4 reference subjects. Results: one patient was diagnosed as clinically brain dead after the MR examination. The patient's ADC values of gray and white matter were significantly lower than those of 3 other brain-injured patients. In addition the ADC value of white matter was significantly lower than that of gray matter. Conclusion: The patient with fatal outcome shortly after MR examination differed significantly from other patients with severe brain injury but non-fatal outcome, with regard to ADC values in gray and white matter. This might indicate a prognostic value of ADC maps in the evaluation of traumatic brain injury

  3. Blood oxygenation level-dependent MRI of the skeletal muscle during ischemia in patients with peripheral arterial occlusive disease

    Energy Technology Data Exchange (ETDEWEB)

    Potthast, Silke [Unispital Basel, Inst. fuer Radiologie (Switzerland); Schulte, A. [Univ. Hospital Ulm (Germany). Clinic for Radiation Therapy and Radiooncology; Kos, S.; Bilecen, D. [Unispital Basel, Interventional Radiology (Switzerland); Aschwanden, M. [Unispital Basel (Switzerland). Angiologie

    2009-12-15

    Purpose: to compare calf muscle Blood Oxygenation Level-Dependent (BOLD) response during ischemia in patients suffering from peripheral arterial occlusive disease (PAOD) and age-matched non-PAOD subjects. Materials and methods: PAOD patients with symptoms of intermittent calf claudication and an age-matched control group underwent T2*-weighted single-shot multi-echo planar imaging on a whole-body MR scanner at 1.5 T. The muscle BOLD signal in the calf was acquired during 60 sec of baseline and 240 sec of ischemia induced by cuff compression. T2* time courses in four calf muscles were evaluated. Results: significant differences in the mean T2* values were noted after 150 sec of measurement (p < 0.05). Patients with PAOD revealed a significantly reduced BOLD signal decrease compared to an age-matched control group. Conclusion: potential cause for this observation may be changes in the structure and/or the metabolic turnover of the muscle in PAOD patients. (orig.)

  4. Normal regional fractional anisotropy and apparent diffusion coefficient of the brain measured on a 3 T MR scanner

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Christabel E.C.; Thomasson, David; Baker, Eva H. [National Institutes of Health, Department of Diagnostic Radiology, Clinical Center, Bethesda, MD (United States); Danielian, Laura E. [National Institutes of Health, National Institute of Neurological Disease and Stroke, Bethesda, MD (United States)

    2009-01-15

    We aim to establish norms of fractional anisotropy (FA) and apparent diffusion coefficient (ADC) in 20 different regions of the brain in healthy human volunteers. Thirty-one individuals were examined for ADC and FA in 20 regions of the brain using a single-shot, spin echo, echo planar diffusion tensor imaging sequence with 32 directions at 3 T. FA and ADC maps were computed using the Philips PRIDE tool, and regions of interest were drawn at 20 different locations in the brain. Relationships of FA and ADC with age and gender were explored. We found a negative correlation between age and FA in the inferior fronto-occipital fasciculus and forceps minor. There were no gender differences. The cerebral peduncle, the middle cerebellum, and cingulum had the highest variation in FA, while fornix, optic radiation, and optic tract had the highest variation in ADC. We provide a table of normative FA and ADC measurements in 20 brain regions of potential clinical relevance to the diagnosis and monitoring of specific neurological diseases. (orig.)

  5. Fetal diffusion tensor quantification of brainstem pathology in Chiari II malformation

    Energy Technology Data Exchange (ETDEWEB)

    Woitek, Ramona; Prayer, Daniela; Weber, Michael; Schoepf, Veronika; Furtner, Julia; Asenbaum, Ulrika; Kasprian, Gregor [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Amann, Gabriele [Medical University of Vienna, Department of Clinical Pathology, Vienna (Austria); Seidl, Rainer [Medical University of Vienna, Department of Paediatrics and Adolescent Medicine, Vienna (Austria); Bettelheim, Dieter [Medical University of Vienna, Department of Obstetrics and Gynecology, Vienna (Austria); Brugger, Peter C. [Medical University of Vienna, Center for Anatomy and Cell Biology, Vienna (Austria)

    2016-05-15

    This prenatal MRI study evaluated the potential of diffusion tensor imaging (DTI) metrics to identify changes in the midbrain of fetuses with Chiari II malformations compared to fetuses with mild ventriculomegaly, hydrocephalus and normal CNS development. Fractional anisotropy (FA) and apparent diffusion coefficient (ADC) were calculated from a region of interest (ROI) in the midbrain of 46 fetuses with normal CNS, 15 with Chiari II malformations, eight with hydrocephalus and 12 with mild ventriculomegaly. Fetuses with different diagnoses were compared group-wise after age-matching. Axial T2W-FSE sequences and single-shot echo planar DTI sequences (16 non-collinear diffusion gradient-encoding directions, b-values of 0 and 700 s/mm{sup 2}, 1.5 Tesla) were evaluated retrospectively. In Chiari II malformations, FA was significantly higher than in age-matched fetuses with a normal CNS (p =.003), while ADC was not significantly different. No differences in DTI metrics between normal controls and fetuses with hydrocephalus or vetriculomegaly were detected. DTI can detect and quantify parenchymal alterations of the fetal midbrain in Chiari II malformations. Therefore, in cases of enlarged fetal ventricles, FA of the fetal midbrain may contribute to the differentiation between Chiari II malformation and other entities. (orig.)

  6. Diffusion-weighted imaging in ischaemic stroke: a follow-up study

    International Nuclear Information System (INIS)

    Weber, J.; Mattle, H.P.; Heid, O.; Remonda, L.; Schroth, G.

    2000-01-01

    Diffusion-weighted (DWI) echo-planar (EPI) MRI has been used for imaging acute ischaemic stroke. We used DWI and conventional spin-echo (SE) MRI to study the dynamics of ischaemic human stroke. We examined 30 patients (mean age 57.5 years, range 27-82 years, median 57 years) with a diagnosis of stroke. They were examined in the acute (120 min to 47 h, mean 15.3 h), subacute (8 days) and chronic (2-3 months) stages of ischaemia using clinical scores and MRI. Imaging was performed on an 1.5-T imager. Anisotropic DWI with diffusion gradients in all three axes, an isotropic tensor trace pulse DWI sequence and SE MRI were used. In all patients both DWI sequences showed a decrease in the apparent diffusion coefficient (ADC) in the acute stage, even when SE images did not reveal signal abnormalities. Clinical features correlated with lesion site but not size. The ADC was initially 19.6-43 % less than that of nonischaemic tissue and increased to normal after 7 days in conventionally treated patients and after 2-5 days in patients who underwent intra-arterial fibrinolysis. In the chronic stage the ADC rose by up to 254.4 %. In patients who did not undergo fibrinolysis DWI changes correlated with the final infarct size (P < 0.05). It was possible to differentiate acute from chronic ischaemic lesions. We conclude that DWI is a sensitive and practicable tool for detecting early cerebral ischaemia. It is possible to predict in the acute stage the final size of an infarct. DWI may be helpful for clinical decisions and for monitoring therapy. (orig.)

  7. MR diffusion weighted imaging with background signal suppression in breast cancer

    International Nuclear Information System (INIS)

    Li Ming; Zhang Bing; Zhou Zhengyang; Yu Haiping; Yuan Lei; Zhu Bin

    2009-01-01

    Objective: To explore the feasibility of echo planar imaging with short time inversion recovery (STIR-EPI) diffusion weighted imaging with background signal (DWIBS) suppression in breast cancer. Methods: The diffusion weighted imaging (DWI)with background suppression (b=800 mm 2 /s) was performed in 26 patients with breast cancer. Apparent diffusion coefficient(ADC) of all lesions were measured and compared. 3D maximum intensity projection (3D-MIP)and reverse black and white technique were used to show the lesions. DWI and DWIBS were performed and compared for the detection of breast cancer. Randomized blocks analysis of variance was used for the ADC values in different breast tissues, the ADC values in breast cancer and benign lesion were compared using t test. The paired chi square test was used for the detection rate of breast cancer in two different imaging methods. Results: Most of the breast cancers were hyperintense on DWI (b=800 mm 2 /s). The ADC value of cancer tissue was (0.93±0.25) x 10 -3 mm 2 /s, tumor necrosis was (2.06±0.17) x 10 -3 mm 2 /s, normal breast tissue was (1.92±0.23) x 10 -3 mm 2 /s and metastatic lymph node was (1.10±0.14) x 10 -3 mm 2 /s and the differences were statistically significant between two structures (P 2 =8.307, P 2 = 12.235, P -3 mm 2 /s and benign lesion (2.15±0.53) x 10 -3 mm 2 /s had significant statistical differences (t=8.626,P<0.05). Conclusion: Diffusion weighted MRI with background suppression can detect more lesions than DWI and can be potentially applied for the detection of the breast cancer combining the ADC value. (authors)

  8. Three-dimensional reconstruction of brain surface anatomy: technique comparison between flash and diffusion-weighted imaging

    International Nuclear Information System (INIS)

    Sun Jianzhong; Wang Zhikang; Gong Xiangyang

    2006-01-01

    Objective: To compare two methods 3D flash and diffusion-weighted images (DWI) in reconstructing the brain surface anatomy, and to evaluate their displaying ability, advantages, limitations and clinical application. Methods: Thrity normal cases were prospectively examined with 3D flash sequence and echo-planar DWI. Three-dimensional images were acquired with volume-rendering on workstation. Brain surface structures were evaluated and scored by a group of doctors. Results: Main structures of brain surface were clearly displayed on three-dimensional images based on 3D flash sequence. Average scores were all above 2.50. For images based on DWI, precentral gyrus, postcentral gyrus, superior parietal lobule, superior frontal gyrus, precentral sulcus, central sulcus, postcentral sulcus, intraparietal sulcus and superior frontal sulcus were best shown with average scores between 2.60-2.75, However, supramarginal gyrus, angular gyrus, middle frontal gyrus, inferior frontal gyrus, superior temporal gyrus, lateral sulcus, inferior frontal sulcus could not be well shown, with average scores between 1.67-2.48. Middle temporal gyrus, inferior temporal gyrus, superior temporal sulcus and inferior temporal sulcus can only get scores from 0.88 to 1.27. Scores of images based on 3D flash were much higher than that based on DWI with distinct differentiations, P values were all below 0.01. Conclusion: Three-dimensional images based on 3D flash can really display brain surface structures. It is very useful for anatomic researches. Three-dimensional reconstruction of brain surface based on DWI is a worthy technique to display brain surface anatomy, especially for frontal and parietal structures. (authors)

  9. Feasibility of diffusion-weighted magnetic resonance imaging in patients with juvenile idiopathic arthritis on 1.0-T open-bore MRI

    Energy Technology Data Exchange (ETDEWEB)

    Barendregt, Anouk M.; Nusman, Charlotte M. [University of Amsterdam, Department of Radiology, Academic Medical Center, Amsterdam (Netherlands); University of Amsterdam, Department of Pediatric Hematology, Immunology, Rheumatology and Infectious Disease, Emma Children' s Hospital AMC, Amsterdam (Netherlands); Hemke, Robert; Lavini, Cristina; Maas, Mario [University of Amsterdam, Department of Radiology, Academic Medical Center, Amsterdam (Netherlands); Amiras, Dimitri [Imperial College Healthcare NHS Trust, Radiology Department, St. Mary' s Hospital, Paddington, London (United Kingdom); Kuijpers, Taco W. [University of Amsterdam, Department of Pediatric Hematology, Immunology, Rheumatology and Infectious Disease, Emma Children' s Hospital AMC, Amsterdam (Netherlands)

    2015-12-15

    To evaluate the feasibility of non-invasive diffusion-weighted imaging (DWI) of the knee of children with juvenile idiopathic arthritis (JIA) and, further, to analyze the apparent diffusion coefficient (ADC) levels to distinguish synovium from effusion. Standard magnetic resonance imaging of the knee including post-contrast imaging was obtained in eight patients (mean age, 12 years 8 months, five females) using an open-bore magnetic resonance imaging system (1.0 T). In addition, axially acquired echo-planar DWI datasets (b-values 0, 50, and 600) were prospectively obtained and the diffusion images were post-processed into ADC{sub 50-600} maps. Two independent observers selected a region of interest (ROI) for both synovium and effusion using aligned post-contrast images as landmarks. Mann-Whitney U test was performed to compare ADC synovium and ADC effusion. DWI was successfully obtained in all patients. When data of both observers was combined, ADC synovium was lower than ADC effusion in the ROI in seven out of eight patients (median, 1.92 x 10{sup -3} mm{sup 2}/s vs. 2.40 x 10{sup -3} mm{sup 2}/s, p = 0.006, respectively). Similar results were obtained when the two observers were analyzed separately (observer 1: p = 0.006, observer 2: p = 0.04). In this pilot study, on a patient-friendly 1.0-T open-bore MRI, we demonstrated that DWI may potentially be a feasible non-invasive imaging technique in children with JIA. We could differentiate synovium from effusion in seven out of eight patients based on the ADC of synovium and effusion. However, to select synovium and effusion on DWI, post-contrast images were still a necessity. (orig.)

  10. Removal of evidential motion-contaminated and poorly fitted image data improves IVIM diffusion MRI parameter scan-rescan reproducibility.

    Science.gov (United States)

    Chevallier, Olivier; Zhou, Nan; He, Jian; Loffroy, Romaric; Wáng, Yì Xiáng J

    2018-01-01

    Background It has been reported that intravoxel incoherent motion (IVIM) diffusion magnetic resonance imaging (MRI) scan-rescan reproducibility is unsatisfactory. Purpose To study IVIM MRI parameter reproducibility for liver parenchyma after the removal of motion-contaminated and/or poorly fitted image data. Material and Methods Eighteen healthy volunteers had liver scans twice in the same session to assess scan-rescan repeatability, and again in another session after an average interval of 13 days to assess reproducibility. Diffusion-weighted images were acquired with a 3-T scanner using respiratory-triggered echo-planar sequence and 16 b-values (0-800 s/mm 2 ). Measurement was performed on the right liver with segment-unconstrained least square fitting. Image series with evidential anatomical mismatch, apparent artifacts, and poorly fitted signal intensity vs. b-value curve were excluded. A minimum of three slices was deemed necessary for IVIM parameter estimation. Results With a total 54 examinations, six did not satisfy inclusion criteria, leading to a success rate of 89%, and 14 volunteers were finally included for the repeatability/reproducibility study. A total of 3-10 slices per examination (mean = 5.3 slices, median = 5 slices) were utilized for analysis. Using threshold b-value = 80 s/mm 2 , the coefficient of variation and within-subject coefficient of variation for repeatability were 2.86% and 3.36% for D slow , 3.81% and 4.24% for perfusion fraction (PF), 18.16% and 24.88% for D fast ; and those for reproducibility were 2.48% and 3.24% for D slow , 4.91% and 5.38% for PF, and 21.18% and 30.89% for D fast . Conclusion Removal of motion-contaminated and/or poorly fitted image data improves IVIM parameter reproducibility.

  11. High temporal resolution magnetic resonance imaging: development of a parallel three dimensional acquisition method for functional neuroimaging

    International Nuclear Information System (INIS)

    Rabrait, C.

    2007-11-01

    Echo Planar Imaging is widely used to perform data acquisition in functional neuroimaging. This sequence allows the acquisition of a set of about 30 slices, covering the whole brain, at a spatial resolution ranging from 2 to 4 mm, and a temporal resolution ranging from 1 to 2 s. It is thus well adapted to the mapping of activated brain areas but does not allow precise study of the brain dynamics. Moreover, temporal interpolation is needed in order to correct for inter-slices delays and 2-dimensional acquisition is subject to vascular in flow artifacts. To improve the estimation of the hemodynamic response functions associated with activation, this thesis aimed at developing a 3-dimensional high temporal resolution acquisition method. To do so, Echo Volume Imaging was combined with reduced field-of-view acquisition and parallel imaging. Indeed, E.V.I. allows the acquisition of a whole volume in Fourier space following a single excitation, but it requires very long echo trains. Parallel imaging and field-of-view reduction are used to reduce the echo train durations by a factor of 4, which allows the acquisition of a 3-dimensional brain volume with limited susceptibility-induced distortions and signal losses, in 200 ms. All imaging parameters have been optimized in order to reduce echo train durations and to maximize S.N.R., so that cerebral activation can be detected with a high level of confidence. Robust detection of brain activation was demonstrated with both visual and auditory paradigms. High temporal resolution hemodynamic response functions could be estimated through selective averaging of the response to the different trials of the stimulation. To further improve S.N.R., the matrix inversions required in parallel reconstruction were regularized, and the impact of the level of regularization on activation detection was investigated. Eventually, potential applications of parallel E.V.I. such as the study of non-stationary effects in the B.O.L.D. response

  12. Spatially selective 2D RF inner field of view (iFOV diffusion kurtosis imaging (DKI of the pediatric spinal cord

    Directory of Open Access Journals (Sweden)

    Chris J. Conklin

    2016-01-01

    Full Text Available Magnetic resonance based diffusion imaging has been gaining more utility and clinical relevance over the past decade. Using conventional echo planar techniques, it is possible to acquire and characterize water diffusion within the central nervous system (CNS; namely in the form of Diffusion Weighted Imaging (DWI and Diffusion Tensor Imaging (DTI. While each modality provides valuable clinical information in terms of the presence of diffusion and its directionality, both techniques are limited to assuming an ideal Gaussian distribution for water displacement with no intermolecular interactions. This assumption neglects pathological processes that are not Gaussian therefore reducing the amount of potentially clinically relevant information. Additions to the Gaussian distribution measured by the excess kurtosis, or peakedness, of the probabilistic model provide a better understanding of the underlying cellular structure. The objective of this work is to provide mathematical and experimental evidence that Diffusion Kurtosis Imaging (DKI can offer additional information about the micromolecular environment of the pediatric spinal cord. This is accomplished by a more thorough characterization of the nature of random water displacement within the cord. A novel DKI imaging sequence based on a tilted 2D spatially selective radio frequency pulse providing reduced field of view (FOV imaging was developed, implemented, and optimized on a 3 Tesla MRI scanner, and tested on pediatric subjects (healthy subjects: 15; patients with spinal cord injury (SCI:5. Software was developed and validated for post processing of the DKI images and estimation of the tensor parameters. The results show statistically significant differences in mean kurtosis (p < 0.01 and radial kurtosis (p < 0.01 between healthy subjects and subjects with SCI. DKI provides incremental and novel information over conventional diffusion acquisitions when coupled with higher order estimation

  13. Novel instrumentation of multispectral imaging technology for detecting tissue abnormity

    Science.gov (United States)

    Yi, Dingrong; Kong, Linghua

    2012-10-01

    Multispectral imaging is becoming a powerful tool in a wide range of biological and clinical studies by adding spectral, spatial and temporal dimensions to visualize tissue abnormity and the underlying biological processes. A conventional spectral imaging system includes two physically separated major components: a band-passing selection device (such as liquid crystal tunable filter and diffraction grating) and a scientific-grade monochromatic camera, and is expensive and bulky. Recently micro-arrayed narrow-band optical mosaic filter was invented and successfully fabricated to reduce the size and cost of multispectral imaging devices in order to meet the clinical requirement for medical diagnostic imaging applications. However the challenging issue of how to integrate and place the micro filter mosaic chip to the targeting focal plane, i.e., the imaging sensor, of an off-shelf CMOS/CCD camera is not reported anywhere. This paper presents the methods and results of integrating such a miniaturized filter with off-shelf CMOS imaging sensors to produce handheld real-time multispectral imaging devices for the application of early stage pressure ulcer (ESPU) detection. Unlike conventional multispectral imaging devices which are bulky and expensive, the resulting handheld real-time multispectral ESPU detector can produce multiple images at different center wavelengths with a single shot, therefore eliminates the image registration procedure required by traditional multispectral imaging technologies.

  14. Microtomography with a sandwich detector for mouse bone imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Ho; Kim, Junwoo; Kim, Ho Kyung [Pusan National University, Busan (Korea, Republic of); Youn, Hanbean; Jeon, Hosang [Pusan National University Yangsan Hospital, Yangsan (Korea, Republic of)

    2015-10-15

    Single-shot dual-energy imaging, using sandwich detector, the rear detector usually uses a thicker x-ray converter to enhance quantum efficiency with the higher-energy spectrum, hence providing a blurrier image than the front detector. The weighted logarithmic subtraction of the two images therefore results in a form of unsharp masking that enhances edges in the resultant image. Inspired by this observation, we have developed a micro computed tomography (micro-CT) system with the sandwich detector for high-resolution bone imaging of small animals. The sandwich detector consists of two flat-panel detectors by stacking one upon the other. Although the x-ray beam continuously irradiates, the step-rotation of an object and stay-readout of projection data were considered for the scanning and data gathering. It will be necessary that more elaborate experiments with the mouse and/or other quantitative phantoms. And quantification of the image quality of bone-enhanced images in comparisons with the conventional images will be performed. The image analysis of differences between bone-enhanced images obtained from the projection- and image-based approaches can be performed.

  15. High signal in bone marrow at diffusion-weighted imaging with body background suppression (DWIBS) in healthy children

    Energy Technology Data Exchange (ETDEWEB)

    Ording Mueller, Lil-Sofie; Avenarius, Derk [University Hospital North Norway, Department of Radiology, Tromsoe (Norway); Olsen, Oeystein E. [Great Ormond Street Hospital for Children, Department of Radiology, London (United Kingdom)

    2011-02-15

    In our experience, diffusion-weighted imaging with body background suppression (DWIBS) is hard to interpret in children who commonly have foci of restricted diffusion in their skeletons unrelated to pathology, sometimes in an asymmetrical pattern. This raises serious concern about the accuracy of DWIBS in cancer staging in children. To describe the signal distribution at DWIBS in the normal developing lumbar spine and pelvic skeleton. Forty-two healthy children underwent an MR DWIBS sequence of the abdomen and pelvis. An axial short-tau inversion-recovery (STIR) echo-planar imaging (EPI) pulse sequence was used. Two radiologists did a primary review of the images and based on these preliminary observations, separate scoring systems for the lumbar spine, pelvis and proximal femoral epiphyses/femoral heads were devised. Visual evaluation of the images was then performed by the two radiologists in consensus. The scoring was repeated separately 2 months later by a third radiologist. Restricted diffusion was defined as areas of high signal compared to the background. Coronal maximum intensity projection (MIP) reformats were used to assess the vertebral bodies. For the pelvis, the extension of high signal for each bone was given a score of 0 to 4. Cohen's Kappa interobserver agreement coefficients of signal distribution and asymmetry were calculated. All children had areas of high signal, both within the lumbar vertebral bodies and within the pelvic skeleton. Three patterns of signal distribution were seen in the lumbar spine, but no specific pattern was seen in the pelvis. There was a tendency toward a reduction of relative area of high signal within each bone with age, but also a widespread interindividual variation. Restricted diffusion is a normal finding in the pelvic skeleton and lumbar spine in children with an asymmetrical distribution seen in 48% of normal children in this study. DWIBS should be used with caution for cancer staging in children as this could

  16. Diffusion-weighted MR neurography of the brachial and lumbosacral plexus: 3.0 T versus 1.5 T imaging

    International Nuclear Information System (INIS)

    Mürtz, P.; Kaschner, M.; Lakghomi, A.; Gieseke, J.; Willinek, W.A.; Schild, H.H.; Thomas, D.

    2015-01-01

    Highlights: •DW MRN of brachial and lumbosacral plexus at 1.5 T and at 3.0 T was compared. •For lumbosacral plexus, nerve conspicuity on MIP images was superior at 3.0 T, also visible length and mean sharpness of the nerves. •For brachial plexus, nerve conspicuity at 3.0 T was rather inferior, nerve length was not significantly different, mean sharpness was superior at 3.0 T. -- Abstract: Purpose: To compare intraindividually the nerve conspicuity of the brachial and lumbosacral plexus on diffusion-weighted (DW) MR neurography (MRN) at two different field strengths. Materials and methods: 16 healthy volunteers were investigated at 3.0 T and 1.5 T applying optimized variants of a DW spin-echo echo-planar imaging sequence with short TI inversion recovery fat suppression. Full-volume (FV) and curved sub-volume (CSV) maximum intensity projection (MIP) images were reconstructed and nerve conspicuity was visually assessed. Moreover, visible length and sharpness of the nerves were quantitatively analyzed. Results: On FV MIP images, nerve conspicuity at 3.0 T compared to 1.5 T was worse for brachial plexus (P = 0.00228), but better for lumbosacral plexus (P = 0.00666). On CSV MIP images, nerve conspicuity did not differ significantly for brachial plexus, but was better at 3.0 T for lumbosacral plexus (P = 0.00091). The visible length of the analyzed nerves did not differ significantly with the exception of some lumbosacral nerves, which were significantly longer at 3.0 T. The sharpness of all investigated nerves was significantly higher at 3.0 T by about 40–60% for cervical and 97–169% for lumbosacral nerves. Conclusion: DW MRN imaging at 3.0 T compared to 1.5 T is superior for lumbosacral plexus, but not for brachial plexus

  17. Diffusion-weighted MR neurography of the brachial and lumbosacral plexus: 3.0 T versus 1.5 T imaging

    Energy Technology Data Exchange (ETDEWEB)

    Mürtz, P., E-mail: petra.muertz@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany); Kaschner, M., E-mail: Marius.Kaschner@med.uni-duesseldorf.de [Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany); Lakghomi, A., E-mail: Asadeh.Lakghomi@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany); Gieseke, J., E-mail: juergen.gieseke@ukb.uni-bonn.de [Philips Healthcare, Lübeckertordamm 5, 20099 Hamburg (Germany); Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany); Willinek, W.A., E-mail: winfried.willinek@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany); Schild, H.H., E-mail: hans.schild@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany); Thomas, D., E-mail: daniel.thomas@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany)

    2015-04-15

    Highlights: •DW MRN of brachial and lumbosacral plexus at 1.5 T and at 3.0 T was compared. •For lumbosacral plexus, nerve conspicuity on MIP images was superior at 3.0 T, also visible length and mean sharpness of the nerves. •For brachial plexus, nerve conspicuity at 3.0 T was rather inferior, nerve length was not significantly different, mean sharpness was superior at 3.0 T. -- Abstract: Purpose: To compare intraindividually the nerve conspicuity of the brachial and lumbosacral plexus on diffusion-weighted (DW) MR neurography (MRN) at two different field strengths. Materials and methods: 16 healthy volunteers were investigated at 3.0 T and 1.5 T applying optimized variants of a DW spin-echo echo-planar imaging sequence with short TI inversion recovery fat suppression. Full-volume (FV) and curved sub-volume (CSV) maximum intensity projection (MIP) images were reconstructed and nerve conspicuity was visually assessed. Moreover, visible length and sharpness of the nerves were quantitatively analyzed. Results: On FV MIP images, nerve conspicuity at 3.0 T compared to 1.5 T was worse for brachial plexus (P = 0.00228), but better for lumbosacral plexus (P = 0.00666). On CSV MIP images, nerve conspicuity did not differ significantly for brachial plexus, but was better at 3.0 T for lumbosacral plexus (P = 0.00091). The visible length of the analyzed nerves did not differ significantly with the exception of some lumbosacral nerves, which were significantly longer at 3.0 T. The sharpness of all investigated nerves was significantly higher at 3.0 T by about 40–60% for cervical and 97–169% for lumbosacral nerves. Conclusion: DW MRN imaging at 3.0 T compared to 1.5 T is superior for lumbosacral plexus, but not for brachial plexus.

  18. In vivo imaging of the time-dependent apparent diffusional kurtosis in the human calf muscle.

    Science.gov (United States)

    Marschar, Anja Maria; Kuder, Tristan Anselm; Stieltjes, Bram; Nagel, Armin Michael; Bachert, Peter; Laun, Frederik Bernd

    2015-06-01

    To evaluate the time dependency of apparent diffusion coefficient Dapp and apparent diffusional kurtosis Kapp in vivo in the human calf. Diffusion-weighted images of five healthy male volunteers were acquired using a 1.5T MR scanner. A stimulated echo sequence with echo planar imaging readout was used with diffusion gradients oriented along the three main axes. Mixing times (TM) of 100, 300, 500, and 700 ms and b-values ranging from 0 to 5600 s/mm(2) were used. Dapp and Kapp were determined. Dapp and Kapp decreased with increasing TM. As an example for absolute values, Dapp of the tibialis anterior drops from 1.18 ± 0.04 μm(2) /ms (TM = 100 ms) to 0.86 ± 0.02 μm(2) /ms (TM = 700 ms) (P = 0.001) and Kapp from 0.38 ± 0.06 to 0.32 ± 0.03 (P = 0.046) for a diffusion weighting along the left-right direction. Kapp was smaller than 0.43 in all muscles and at all TMs. The clearly observed time-dependence of Dapp and Kapp is an indicator of restricted diffusion in muscle tissue and may thus be a promising marker to investigate alterations of the microstructure. Compared to typical kurtosis values in white matter tissue of the brain, the kurtosis in muscle tissue is much smaller, which we attribute to the absence of the almost impermeable myelin sheath. © 2014 Wiley Periodicals, Inc.

  19. Brain Activity in Patients With Adductor Spasmodic Dysphonia Detected by Functional Magnetic Resonance Imaging.

    Science.gov (United States)

    Kiyuna, Asanori; Kise, Norimoto; Hiratsuka, Munehisa; Kondo, Shunsuke; Uehara, Takayuki; Maeda, Hiroyuki; Ganaha, Akira; Suzuki, Mikio

    2017-05-01

    Spasmodic dysphonia (SD) is considered a focal dystonia. However, the detailed pathophysiology of SD remains unclear, despite the detection of abnormal activity in several brain regions. The aim of this study was to clarify the pathophysiological background of SD. This is a case-control study. Both task-related brain activity measured by functional magnetic resonance imaging by reading the five-digit numbers and resting-state functional connectivity (FC) measured by 150 T2-weighted echo planar images acquired without any task were investigated in 12 patients with adductor SD and in 16 healthy controls. The patients with SD showed significantly higher task-related brain activation in the left middle temporal gyrus, left thalamus, bilateral primary motor area, bilateral premotor area, bilateral cerebellum, bilateral somatosensory area, right insula, and right putamen compared with the controls. Region of interest voxel FC analysis revealed many FC changes within the cerebellum-basal ganglia-thalamus-cortex loop in the patients with SD. Of the significant connectivity changes between the patients with SD and the controls, the FC between the left thalamus and the left caudate nucleus was significantly correlated with clinical parameters in SD. The higher task-related brain activity in the insula and cerebellum was consistent with previous neuroimaging studies, suggesting that these areas are one of the unique characteristics of phonation-induced brain activity in SD. Based on FC analysis and their significant correlations with clinical parameters, the basal ganglia network plays an important role in the pathogenesis of SD. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  20. SNAPSHOT SPECTRAL AND COLOR IMAGING USING A REGULAR DIGITAL CAMERA WITH A MONOCHROMATIC IMAGE SENSOR

    Directory of Open Access Journals (Sweden)

    J. Hauser

    2017-10-01

    Full Text Available Spectral imaging (SI refers to the acquisition of the three-dimensional (3D spectral cube of spatial and spectral data of a source object at a limited number of wavelengths in a given wavelength range. Snapshot spectral imaging (SSI refers to the instantaneous acquisition (in a single shot of the spectral cube, a process suitable for fast changing objects. Known SSI devices exhibit large total track length (TTL, weight and production costs and relatively low optical throughput. We present a simple SSI camera based on a regular digital camera with (i an added diffusing and dispersing phase-only static optical element at the entrance pupil (diffuser and (ii tailored compressed sensing (CS methods for digital processing of the diffused and dispersed (DD image recorded on the image sensor. The diffuser is designed to mix the spectral cube data spectrally and spatially and thus to enable convergence in its reconstruction by CS-based algorithms. In addition to performing SSI, this SSI camera is capable to perform color imaging using a monochromatic or gray-scale image sensor without color filter arrays.

  1. A study on the activation of supplementary motor area in functional magnetic resonance imaging of the brain

    International Nuclear Information System (INIS)

    Jin, Gong Yong; Chung, Gyung Ho; Park, Hark Hoon; Oh, Hee Sul; Kim, Chong Soo; Chung, Jin Young

    1999-01-01

    To evaluate the activated zone of the supplementary motor area through motor and sensory stimulation of both hands by fMRI. Twenty-four healthy volunteers, ranging in age from 20 to 30 years, served as subjects. They were divided into four groups and performed one of the four activation tasks : complex movement, fine movement, touch sensation, heat sensation. Complex movement consisted of a finger task in which subjects flexed and extended all fingers repeatedly in union, without the fingers touching each other(group I). Fine movement involved a thumb task in which subjects flexed and extended the thumb repeatedly without touching the other fingers(group II). Touch sensation consisted of a palm task in which another person repeatedly drew a circle on the subject's palm (group III), and heat sensation involved of a palm task in which subject's palm was touched by another person with a 40 deg C water-bag (group IV). F-MRI was conducted on a commercial 1.5-T scanner equipped with echo-planar imaging. After overlapping images were obtained using a Z-s-core, and the mean/curve in the MR devices was evaluated, the activated zone of the supplementary motor area was also evalvated. Thirty-two of 48 images(20 of the 24 men) revealed activated zones in the supplementary motor area. In group I, activation was observed in five subjects, in three of whom it was bilateral (contralateral activation). In group II, activation was observed in five subjects, in one of whom it was bilateral. In group III, activation occurred in five subjects(bilateral in four, and contralateral in three), and In group IV, activation was also observed in five;in three of these it was bilateral. Using fMRI, and in association with motor and sensory tasks, the supplementary motor area was activated in 66.7% of healthy volunteers (32/48)

  2. Measurement of choroid plexus perfusion using dynamic susceptibility MR imaging: capillary permeability and age-related changes

    Energy Technology Data Exchange (ETDEWEB)

    Bouzerar, Roger; Chaarani, Bader; Baledent, Olivier [University Hospital, Image Processing Department, Amiens (France); Gondry-Jouet, Catherine [University Hospital, Radiology Department, Amiens (France); Zmudka, Jadwiga [University Hospital, Geriatric Unit, Amiens (France)

    2013-12-15

    The cerebrospinal fluid (CSF) plays a major role in the physiology of the central nervous system. The continuous turnover of CSF is mainly attributed to the highly vascularized choroid plexus (CP) located in the cerebral ventricles which represent a complex interface between blood and CSF. We propose a method for evaluating CP functionality in vivo using perfusion MR imaging and establish the age-related changes of associated parameters. Fifteen patients with small intracranial tumors were retrospectively studied. MR Imaging was performed on a 3T MR Scanner. Gradient-echo echo planar images were acquired after bolus injection of gadolinium-based contrast agent (CA). The software developed used the combined T1- and T2-effects. The decomposition of the relaxivity signals enables the calculation of the CP capillary permeability (K{sub 2}). The relative cerebral blood volume (rCBV), mean transit time (MTT), and signal slope decrease (SSD) were also calculated. The mean permeability K{sub 2} of the extracted CP was 0.033+/-0.18 s{sup -1}. K{sub 2} and SSD significantly decreased with subject's age whereas MTT significantly increased with subject's age. No significant correlation was found for age-related changes in rCBV and rCBF. The decrease in CP permeability is in line with the age-related changes in CSF secretion observed in animals. The MTT increase indicates significant structural changes corroborated by microscopy studies in animals or humans. Overall, DSC MR-perfusion enables an in vivo evaluation of the hemodynamic state of CP. Clinical applications such as neurodegenerative diseases could be considered thanks to specific functional studies of CP. (orig.)

  3. Cingulum correlates of cognitive functions in patients with mild cognitive impairment and early Alzheimer's disease: a diffusion spectrum imaging study.

    Science.gov (United States)

    Lin, Yi-Cheng; Shih, Yao-Chia; Tseng, Wen-Yih I; Chu, Yu-Hsiu; Wu, Meng-Tien; Chen, Ta-Fu; Tang, Pei-Fang; Chiu, Ming-Jang

    2014-05-01

    Diffusion spectrum imaging (DSI) of MRI can detect neural fiber tract changes. We investigated integrity of cingulum bundle (CB) in patients with mild cognitive impairment (MCI) and early Alzheimer's disease (EAD) using DSI tractography and explored its relationship with cognitive functions. We recruited 8 patients with MCI, 9 with EAD and 15 healthy controls (HC). All subjects received a battery of neuropsychological tests to access their executive, memory and language functions. We used a 3.0-tesla MRI scanner to obtain T1- and T2-weighted images for anatomy and used a pulsed gradient twice-refocused spin-echo diffusion echo-planar imaging sequence to acquire DSI. Patients with EAD performed significantly poorer than the HC on most tests in executive and memory functions. Significantly smaller general fractional anisotropy (GFA) values were found in the posterior and inferior segments of left CB and of the anterior segment of right CB of the EAD compared with those of the HC. Spearman's correlation on the patient groups showed that GFA values of the posterior segment of the left CB were significantly negatively associated with the time used to complete Color Trails Test Part II and positively correlated with performance of the logical memory and visual reproduction. GFA values of inferior segment of bilateral CB were positively associated with the performance of visual recognition. DSI tractography demonstrates significant preferential degeneration of the CB on the left side in patients with EAD. The location-specific degeneration is associated with corresponding declines in both executive and memory functions.

  4. Diffusion MRI processing for multi-compartment characterization of brain pathology

    International Nuclear Information System (INIS)

    Hedouin, Renaud

    2017-01-01

    Diffusion weighted imaging (DWI) is a specific type of MRI acquisition based on the direction of diffusion of the brain water molecules. It allows, through several acquisitions, to model the brain microstructure, as white matter, which is significantly smaller than the voxel-resolution. To acquire a large number of images in a clinical setting, very-fast acquisition techniques are required as single-shot imaging. However these acquisitions suffer locally large distortions. We propose a block-matching registration method based on the acquisition of images with opposite phase-encoding directions (PED). This technique specially designed for Echo-Planar Images (EPI) robustly correct images and provides a deformation field. This field is applicable to an entire DWI series from only one reversed EPI allowing distortion correction with a minimal acquisition time cost. This registration algorithm has been validated both on phantom and on in vivo data and is available in our source medical image processing toolbox Anima. From these diffusion images, we are able to construct multi-compartments models (MCM) which can represent complex brain microstructure. Doing registration, averaging and atlas creation on these MCM images is required to perform studies and statistic analyses. We propose a general method to interpolate MCM as a simplification problem based on spectral clustering. This technique, which is adaptable for any MCM, has been validated on both synthetic and real data. Then, from a registered dataset, we performed a patient to population analysis at a voxel-level computing statistics on MCM parameters. Specifically designed tractography can also be used to make analysis, following tracks, based on individual anisotropic compartments. All these tools are designed and used on real data and contribute to the search of bio-markers for brain diseases such as multiple sclerosis. (author)

  5. First Human Experience with Directly Image-able Iodinated Embolization Microbeads

    Energy Technology Data Exchange (ETDEWEB)

    Levy, Elliot B., E-mail: levyeb@cc.nih.gov; Krishnasamy, Venkatesh P. [National Institutes of Health, Center for Interventional Oncology (United States); Lewis, Andrew L.; Willis, Sean; Macfarlane, Chelsea [Biocompatibles, UK Ltd, A BTG International Group Company (United Kingdom); Anderson, Victoria [National Institutes of Health, Center for Interventional Oncology (United States); Bom, Imramsjah MJ van der [Clinical Science IGT Systems North & Latin America, Philips, Philips, Image Guided Interventions (United States); Radaelli, Alessandro [Image-Guided Therapy Systems, Philips, Philips, Image Guided Interventions (Netherlands); Dreher, Matthew R. [Biocompatibles, UK Ltd, A BTG International Group Company (United Kingdom); Sharma, Karun V. [Children’s National Medical Center (United States); Negussie, Ayele; Mikhail, Andrew S. [National Institutes of Health, Center for Interventional Oncology (United States); Geschwind, Jean-Francois H. [Department of Radiology and Biomedical Imaging (United States); Wood, Bradford J. [National Institutes of Health, Center for Interventional Oncology (United States)

    2016-08-15

    PurposeTo describe first clinical experience with a directly image-able, inherently radio-opaque microspherical embolic agent for transarterial embolization of liver tumors.MethodologyLC Bead LUMI™ is a new product based upon sulfonate-modified polyvinyl alcohol hydrogel microbeads with covalently bound iodine (~260 mg I/ml). 70–150 μ LC Bead LUMI™ iodinated microbeads were injected selectively via a 2.8 Fr microcatheter to near complete flow stasis into hepatic arteries in three patients with hepatocellular carcinoma, carcinoid, or neuroendocrine tumor. A custom imaging platform tuned for LC LUMI™ microbead conspicuity using a cone beam CT (CBCT)/angiographic C-arm system (Allura Clarity FD20, Philips) was used along with CBCT embolization treatment planning software (EmboGuide, Philips).ResultsLC Bead LUMI™ image-able microbeads were easily delivered and monitored during the procedure using fluoroscopy, single-shot radiography (SSD), digital subtraction angiography (DSA), dual-phase enhanced and unenhanced CBCT, and unenhanced conventional CT obtained 48 h after the procedure. Intra-procedural imaging demonstrated tumor at risk for potential under-treatment, defined as paucity of image-able microbeads within a portion of the tumor which was confirmed at 48 h CT imaging. Fusion of pre- and post-embolization CBCT identified vessels without beads that corresponded to enhancing tumor tissue in the same location on follow-up imaging (48 h post).ConclusionLC Bead LUMI™ image-able microbeads provide real-time feedback and geographic localization of treatment in real time during treatment. The distribution and density of image-able beads within a tumor need further evaluation as an additional endpoint for embolization.

  6. Evaluating laser-driven Bremsstrahlung radiation sources for imaging and analysis of nuclear waste packages

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Christopher P., E-mail: cj0810@bristol.ac.uk [Interface Analysis Centre, HH Wills Physics Laboratory, Tyndall Avenue, Bristol BS8 1TL (United Kingdom); Brenner, Ceri M. [Central Laser Facility, STFC, Rutherford Appleton Laboratory, Didcot, Oxon OX11 0QX (United Kingdom); Stitt, Camilla A. [Interface Analysis Centre, HH Wills Physics Laboratory, Tyndall Avenue, Bristol BS8 1TL (United Kingdom); Armstrong, Chris; Rusby, Dean R. [Central Laser Facility, STFC, Rutherford Appleton Laboratory, Didcot, Oxon OX11 0QX (United Kingdom); Department of Physics, SUPA, University of Strathclyde, Glasgow G4 0NG (United Kingdom); Mirfayzi, Seyed R. [Centre for Plasma Physics, Queen' s University Belfast, Belfast BT7 1NN (United Kingdom); Wilson, Lucy A. [Central Laser Facility, STFC, Rutherford Appleton Laboratory, Didcot, Oxon OX11 0QX (United Kingdom); Alejo, Aarón; Ahmed, Hamad [Centre for Plasma Physics, Queen' s University Belfast, Belfast BT7 1NN (United Kingdom); Allott, Ric [Central Laser Facility, STFC, Rutherford Appleton Laboratory, Didcot, Oxon OX11 0QX (United Kingdom); Butler, Nicholas M.H. [Department of Physics, SUPA, University of Strathclyde, Glasgow G4 0NG (United Kingdom); Clarke, Robert J.; Haddock, David; Hernandez-Gomez, Cristina [Central Laser Facility, STFC, Rutherford Appleton Laboratory, Didcot, Oxon OX11 0QX (United Kingdom); Higginson, Adam [Department of Physics, SUPA, University of Strathclyde, Glasgow G4 0NG (United Kingdom); Murphy, Christopher [Department of Physics, University of York, York YO10 5DD (United Kingdom); Notley, Margaret [Central Laser Facility, STFC, Rutherford Appleton Laboratory, Didcot, Oxon OX11 0QX (United Kingdom); Paraskevoulakos, Charilaos [Interface Analysis Centre, HH Wills Physics Laboratory, Tyndall Avenue, Bristol BS8 1TL (United Kingdom); Jowsey, John [Ground Floor North B582, Sellafield Ltd, Seascale, Cumbria CA20 1PG (United Kingdom); and others

    2016-11-15

    Highlights: • X-ray generation was achieved via laser interaction with a tantalum thin foil target. • Picosecond X-ray pulse from a sub-mm spot generated high resolution images. • MeV X-ray emission is possible, permitting analysis of full scale waste containers. • In parallel neutron emission of 10{sup 7}–10{sup 9} neutrons per steradian per pulse was attained. • Development of a 10 Hz diode pumped laser system for waste monitoring is envisioned. - Abstract: A small scale sample nuclear waste package, consisting of a 28 mm diameter uranium penny encased in grout, was imaged by absorption contrast radiography using a single pulse exposure from an X-ray source driven by a high-power laser. The Vulcan laser was used to deliver a focused pulse of photons to a tantalum foil, in order to generate a bright burst of highly penetrating X-rays (with energy >500 keV), with a source size of <0.5 mm. BAS-TR and BAS-SR image plates were used for image capture, alongside a newly developed Thalium doped Caesium Iodide scintillator-based detector coupled to CCD chips. The uranium penny was clearly resolved to sub-mm accuracy over a 30 cm{sup 2} scan area from a single shot acquisition. In addition, neutron generation was demonstrated in situ with the X-ray beam, with a single shot, thus demonstrating the potential for multi-modal criticality testing of waste materials. This feasibility study successfully demonstrated non-destructive radiography of encapsulated, high density, nuclear material. With recent developments of high-power laser systems, to 10 Hz operation, a laser-driven multi-modal beamline for waste monitoring applications is envisioned.

  7. The Travelling-Wave Primate System: A New Solution for Magnetic Resonance Imaging of Macaque Monkeys at 7 Tesla Ultra-High Field.

    Directory of Open Access Journals (Sweden)

    Tim Herrmann

    Full Text Available Neuroimaging of macaques at ultra-high field (UHF is usually conducted by combining a volume coil for transmit (Tx and a phased array coil for receive (Rx tightly enclosing the monkey's head. Good results have been achieved using vertical or horizontal magnets with implanted or near-surface coils. An alternative and less costly approach, the travelling-wave (TW excitation concept, may offer more flexible experimental setups on human whole-body UHF magnetic resonance imaging (MRI systems, which are now more widely available. Goal of the study was developing and validating the TW concept for in vivo primate MRI.The TW Primate System (TWPS uses the radio frequency shield of the gradient system of a human whole-body 7 T MRI system as a waveguide to propagate a circularly polarized B1 field represented by the TE11 mode. This mode is excited by a specifically designed 2-port patch antenna. For receive, a customized neuroimaging monkey head receive-only coil was designed. Field simulation was used for development and evaluation. Signal-to-noise ratio (SNR was compared with data acquired with a conventional monkey volume head coil consisting of a homogeneous transmit coil and a 12-element receive coil.The TWPS offered good image homogeneity in the volume-of-interest Turbo spin echo images exhibited a high contrast, allowing a clear depiction of the cerebral anatomy. As a prerequisite for functional MRI, whole brain ultrafast echo planar images were successfully acquired.The TWPS presents a promising new approach to fMRI of macaques for research groups with access to a horizontal UHF MRI system.

  8. INFRARED MATRIX-ASSISTED LASER DESORPTION ELECTROSPRAY IONIZATION (IR-MALDESI) IMAGING SOURCE COUPLED TO A FT-ICR MASS SPECTROMETER

    Science.gov (United States)

    Robichaud, Guillaume; Barry, Jeremy A.; Garrard, Kenneth P.; Muddiman, David C.

    2013-01-01

    Mass spectrometry imaging (MSI) allows for the direct monitoring of the abundance and spatial distribution of chemical compounds over the surface of a tissue sample. This technology has opened the field of mass spectrometry to numerous innovative applications over the past 15 years. First used with SIMS and MALDI MS that operate under vacuum, interest has grown for mass spectrometry ionization sources that allow for effective imaging but where the analysis can be performed at ambient pressure with minimal or no sample preparation. We introduce here a versatile source for MALDESI imaging analysis coupled to a hybrid LTQ-FT-ICR mass spectrometer. The imaging source offers single shot or multi-shot capability per pixel with full control over the laser repetition rate and mass spectrometer scanning cycle. Scanning rates can be as fast as 1 pixel/second and a spatial resolution of 45 μm was achieved with oversampling. PMID:23208743

  9. Visualization of the medial forebrain bundle using diffusion tensor imaging

    Directory of Open Access Journals (Sweden)

    Ardian eHana

    2015-10-01

    Full Text Available Diffusion tensor imaging is a technique that enables physicians the portrayal of white matter tracts in vivo. We used this technique in order to depict the medial forebrain bundle in 15 consecutive patients between 2012 and 2015. Men and women of all ages were included. There were 6 women and 9 men. The mean age was 58,6 years (39-77. Nine patients were candidates for an eventual deep brain stimulation. Eight of them suffered from Parkinson`s disease and one had multiple sclerosis. The remaining 6 patients suffered from different lesions which were situated in the frontal lobe. These were 2 metastasis, 2 meningiomas, 1 cerebral bleeding and 1 glioblastoma. We used a 3DT1-sequence for the navigation. Furthermore T2- and DTI- sequences were performed. The FOV was 200 x 200 mm², slice thickness 2 mm, and an acquisition matrix of 96 x 96 yielding nearly isotropic voxels of 2 x 2 x 2 mm. 3-Tesla-MRI was carried out strictly axial using 32 gradient directions and one b0-image. We used Echo-Planar-Imaging (EPI and ASSET parallel imaging with an acceleration factor of 2. b-value was 800 s/mm². The maximal angle was 50°. Additional scanning time was less than 9 minutes. We were able to visualize the medial forebrain bundle in 12 of our patients bilaterally and in the remaining 3 patients we depicted the medial forebrain bundle on one side. It was the contralateral side of the lesion. These were 2 meningiomas and one metastasis. Portrayal of the medial forebrain bundle is possible for everyday routine for neurosurgical interventions. As part of the reward circuitry it might be of substantial importance for neurosurgeons during deep brain stimulation in patients with psychiatric disorders. Furthermore it might explain at a certain extent character changes in patients with lesions in the frontal lobe. Surgery in this part of the brain should always take the preservation of this white matter tract into account.

  10. High-Speed Real-Time Resting State fMRI using Multi-Slab Echo-Volumar Imaging

    Directory of Open Access Journals (Sweden)

    Stefan ePosse

    2013-08-01

    Full Text Available We recently demonstrated that ultra-high-speed real-time fMRI using multi-slab echo-volumar imaging (MEVI significantly increases sensitivity for mapping task-related activation and resting state networks (RSNs compared to echo-planar imaging (Posse et al. 2012. In the present study we characterize the sensitivity of MEVI for mapping RSN connectivity dynamics, comparing independent component analysis (ICA and a novel seed-based connectivity analysis (SBCA that combines sliding-window correlation analysis with meta-statistics. This SBCA approach is shown to minimize the effects of confounds, such as movement, and CSF and white matter signal changes, and enables real-time monitoring of RSN dynamics at time scales of tens of seconds. We demonstrate highly sensitive mapping of eloquent cortex in the vicinity of brain tumors and arteriovenous malformations, and detection of abnormal resting state connectivity in epilepsy. In patients with motor impairment, resting state fMRI provided focal localization of sensorimotor cortex compared with more diffuse activation in task-based fMRI. The fast acquisition speed of MEVI enabled segregation of cardiac-related signal pulsation using ICA, which revealed distinct regional differences in pulsation amplitude and waveform, elevated signal pulsation in patients with arteriovenous malformations and a trend towards reduced pulsatility in gray matter of patients compared with healthy controls. Mapping cardiac pulsation in cortical gray matter may carry important functional information that distinguishes healthy from diseased tissue vasculature. This novel fMRI methodology is particularly promising for mapping eloquent cortex in patients with neurological disease, having variable degree of cooperation in task-based fMRI. In conclusion, ultra-high-real-time speed fMRI enhances the sensitivity of mapping the dynamics of resting state connectivity and cerebrovascular pulsatility for clinical and neuroscience research

  11. Enhancement of Temporal Resolution and BOLD Sensitivity in Real-Time fMRI using Multi-Slab Echo-Volumar Imaging

    Science.gov (United States)

    Posse, Stefan; Ackley, Elena; Mutihac, Radu; Rick, Jochen; Shane, Matthew; Murray-Krezan, Cristina; Zaitsev, Maxim; Speck, Oliver

    2012-01-01

    In this study, a new approach to high-speed fMRI using multi-slab echo-volumar imaging (EVI) is developed that minimizes geometrical image distortion and spatial blurring, and enables nonaliased sampling of physiological signal fluctuation to increase BOLD sensitivity compared to conventional echo-planar imaging (EPI). Real-time fMRI using whole brain 4-slab EVI with 286 ms temporal resolution (4 mm isotropic voxel size) and partial brain 2-slab EVI with 136 ms temporal resolution (4×4×6 mm3 voxel size) was performed on a clinical 3 Tesla MRI scanner equipped with 12-channel head coil. Four-slab EVI of visual and motor tasks significantly increased mean (visual: 96%, motor: 66%) and maximum t-score (visual: 263%, motor: 124%) and mean (visual: 59%, motor: 131%) and maximum (visual: 29%, motor: 67%) BOLD signal amplitude compared with EPI. Time domain moving average filtering (2 s width) to suppress physiological noise from cardiac and respiratory fluctuations further improved mean (visual: 196%, motor: 140%) and maximum (visual: 384%, motor: 200%) t-scores and increased extents of activation (visual: 73%, motor: 70%) compared to EPI. Similar sensitivity enhancement, which is attributed to high sampling rate at only moderately reduced temporal signal-to-noise ratio (mean: − 52%) and longer sampling of the BOLD effect in the echo-time domain compared to EPI, was measured in auditory cortex. Two-slab EVI further improved temporal resolution for measuring task-related activation and enabled mapping of five major resting state networks (RSNs) in individual subjects in 5 min scans. The bilateral sensorimotor, the default mode and the occipital RSNs were detectable in time frames as short as 75 s. In conclusion, the high sampling rate of real-time multi-slab EVI significantly improves sensitivity for studying the temporal dynamics of hemodynamic responses and for characterizing functional networks at high field strength in short measurement times. PMID:22398395

  12. Evaluation of the female pelvic floor in pelvic organ prolapse using 3.0-Tesla diffusion tensor imaging and fibre tractography

    Energy Technology Data Exchange (ETDEWEB)

    Zijta, F.M. [University of Amsterdam, Department of Radiology, Academic Medical Centre, Amsterdam (Netherlands); Onze Lieve Vrouwe Gasthuis, Amsterdam and Department of Radiology, Amsterdam (Netherlands); Academic Medical Center, Department of Radiology, Amsterdam, AZ (Netherlands); Lakeman, M.M.E.; Roovers, J.P. [University of Amsterdam the Netherlands and Biomedical NMR, Amsterdam and Department of Gynaecology, Academic Medical Centre, Amsterdam (Netherlands); Froeling, M. [University of Amsterdam, Department of Radiology, Academic Medical Centre, Amsterdam (Netherlands); Eindhoven University of Technology, Department of Biomedical Engineering, Eindhoven (Netherlands); Paardt, M.P. van der; Borstlap, C.S.V.; Bipat, S.; Nederveen, A.J.; Stoker, J. [University of Amsterdam, Department of Radiology, Academic Medical Centre, Amsterdam (Netherlands); Montauban van Swijndregt, A.D. [Onze Lieve Vrouwe Gasthuis, Amsterdam and Department of Radiology, Amsterdam (Netherlands); Strijkers, G.J. [Eindhoven University of Technology, Department of Biomedical Engineering, Eindhoven (Netherlands)

    2012-12-15

    To prospectively explore the clinical application of diffusion tensor imaging (DTI) and fibre tractography in evaluating the pelvic floor. Ten patients with pelvic organ prolapse, ten with pelvic floor symptoms and ten asymptomatic women were included. A two-dimensional (2D) spin-echo (SE) echo-planar imaging (EPI) sequence of the pelvic floor was acquired. Offline fibre tractography and morphological analysis of pelvic magnetic resonance imaging (MRI) were performed. Inter-rater agreement for quality assessment of fibre tracking results was evaluated using weighted kappa ({kappa}). From agreed tracking results, eigen values ({lambda}1, {lambda}2, {lambda}3), mean diffusivity (MD) and fractional anisotropy (FA) were calculated. MD and FA values were compared using ANOVA. Inter-rater reliability of DTI parameters was interpreted using the intra-class correlation coefficient (ICC). Substantial inter-rater agreement was found ({kappa} = 0.71 [95% CI 0.63-0.78]). Four anatomical structures were reliably identified. Substantial inter-rater agreement was found for MD and FA (ICC 0.60-0.91). No significant differences between groups were observed for anal sphincter, perineal body and puboperineal muscle. A significant difference in FA was found for internal obturator muscle between the prolapse group and the asymptomatic group (0.27 {+-} 0.05 vs 0.22 {+-} 0.03; P = 0.015). DTI with fibre tractography permits identification of part of the clinically relevant pelvic structures. Overall, no significant differences in DTI parameters were found between groups. circle Diffusion tensor MRI offers new insights into female pelvic floor problems. (orig.)

  13. Functional magnetic resonance imaging (fMRI) in patients with gliomas adjacent to classical language areas. Lateralization of activated prefrontal cortex is important in determining the dominant hemisphere

    International Nuclear Information System (INIS)

    Karibe, Hiroshi; Kumabe, Toshihiro; Shirane, Reizo; Yoshimoto, Takashi

    2003-01-01

    In patients with gliomas adjacent to classical language areas, lateralized activation of prefrontal cortex was assessed to determine language dominant hemisphere using functional magnetic resonance imaging (fMRI). Twelve patients presented with aphasias were studied. In all patients, either the left frontal operculum or left superior temporal gyri were adjacent to gliomas, suggesting all patients had left lateralization in hemispheric language dominance. Functional MRI was performed with a 1.5T scanner, with the sequence of gradient-echo type echo-planar imaging. As specific language tasks, verb, word, and capping generations were used. Using a cross-correlation analysis method, primary activation maps were generated using pixels with a correlation coefficient of >0.7. The lateralized activation of frontal operculum, superior temporal gyrus, and prefrontal cortex were assessed by calculating laterality index. Successful activation of frontal operculum was imaged in 11 of 12, in the superior temporal gyrus or prefrontal cortex. Three out of 11 cases had apparent activation lateralized in the right frontal operculum on fMRI, while 3 out of 12 cases showed activation in the superior temporal gyrus. On the other hand, all cases had apparent activation lateralized to the left prefrontal cortex. Significant activation of true language area may not be obtained in some cases with gliomas adjacent to classical language areas. In such cases, lateralization of apparent activation of prefrontal cortex may reflect lateralization in the dominant hemisphere. These result suggest that the assessment of apparent activation of prefrontal cortex lateralization is useful to determine the language dominant hemisphere. (author)

  14. Diffusion Tensor Imaging of the Kidneys: Influence of b-Value and Number of Encoding Directions on Image Quality and Diffusion Tensor Parameters

    Directory of Open Access Journals (Sweden)

    Natalie C Chuck

    2013-01-01

    Full Text Available Objectives: The purpose of this study was to evaluate to which degree investment of acquisition time in more encoding directions leads to better image quality (IQ and what influence the number of encoding directions and the choice of b-values have on renal diffusion tensor imaging (DTI parameters. Material and Methods: Eight healthy volunteers (32.3 y ± 5.1 y consented to an examination in a 1.5T whole-body MR scanner. Coronal DTI data sets of the kidneys were acquired with systematic variation of b-values (50, 150, 300, 500, and 700 s/mm 2 and number of diffusion-encoding directions (6, 15, and 32 using a respiratory-triggered echo-planar sequence (TR/TE 1500 ms/67 ms, matrix size 128 × 128. Additionally, two data sets with more than two b-values were acquired (0, 150, and 300 s/mm 2 and all six b-values. Parametrical maps were calculated on a pixel-by-pixel basis. Image quality was determined with a reader score. Results: Best IQ was visually assessed for images acquired with 15 and 32 encoding directions, whereas images acquired with six directions had significantly lower IQ ratings. Image quality, fractional anisotropy, and mean diffusivity only varied insignificantly for b-values between 300 and 500 s/mm 2 . In the renal medulla fractional anisotropy (FA values between 0.43 and 0.46 and mean diffusivity (MD values between 1.8-2.1 × 10 -3 mm 2 /s were observed. In the renal cortex, the corresponding ranges were 0.24-0.25 (FA and 2.2-2.8 × 10 -3 mm 2 /s (MD. Including b-values below 300 s/mm 2 , notably higher MD values were observed, while FA remained constant. Susceptibility artifacts were more prominent in FA maps than in MD maps. Conclusion: In DTI of the kidneys at 1.5T, the best compromise between acquisition time and resulting image quality seems the application of 15 encoding directions with b-values between 300 and 500 s/mm 2 . Including lower b-values allows for assessment of fast diffusing spin components.

  15. Images.

    Science.gov (United States)

    Barr, Catherine, Ed.

    1997-01-01

    The theme of this month's issue is "Images"--from early paintings and statuary to computer-generated design. Resources on the theme include Web sites, CD-ROMs and software, videos, books, and others. A page of reproducible activities is also provided. Features include photojournalism, inspirational Web sites, art history, pop art, and myths. (AEF)

  16. High-speed CH planar laser-induced fluorescence imaging using a multimode-pumped optical parametric oscillator.

    Science.gov (United States)

    Miller, Joseph D; Engel, Sascha R; Meyer, Terrence R; Seeger, Thomas; Leipertz, Alfred

    2011-10-01

    We report on high-speed CH planar laser-induced fluorescence (PLIF) imaging in turbulent diffusion flames using a multimode-pumped optical parametric oscillator (OPO). The OPO is pumped by the third-harmonic output of a multimode Nd:YAG cluster for direct signal excitation in the A-X (0,0) band of the CH radical. The lasing threshold, conversion efficiency, and linewidth are shown to depend on the number of pump passes in the ring cavity of the OPO. Single-shot CH PLIF images are acquired at 10 kHz with excitation energy up to 6 mJ/pulse at 431.1 nm. Signal-to-noise ratios of ~25-35 are the highest yet reported for high-speed CH PLIF. © 2011 Optical Society of America

  17. Time-resolved imaging using x-ray free electron lasers

    International Nuclear Information System (INIS)

    Barty, Anton

    2010-01-01

    The ultra-intense, ultra-short x-ray pulses provided by x-ray free electron laser (XFEL) sources are ideally suited to time-resolved studies of structural dynamics with spatial resolution from nanometre to atomic length scales and a temporal resolution of 10 fs or less. With enough photons in a single pulse to enable single-shot measurements and short enough pulses to freeze atomic motion, researchers now have a new window into the time evolution ultrafast phenomena that are intrinsically not cyclic in nature. In this paper we recap some of the key time-resolved imaging experiments performed at FLASH and look ahead to a new generation of experiments at higher resolution using a new generation of new XFEL sources that are only just becoming available.

  18. Lasers As Particle Accelerators In Medicine: From Laser-Driven Protons To Imaging With Thomson Sources

    Science.gov (United States)

    Pogorelsky, I. V.; Babzien, M.; Polyanskiy, M. N.; Yakimenko, V.; Dover, N. P.; Palmer, C. A. J.; Najmudin, Z.; Shkolnikov, P.; Williams, O.; Rosenzweig, J.; Oliva, P.; Carpinelli, M.; Golosio, B.; Delogu, P.; Stefanini, A.; Endrizzi, M.

    2011-06-01

    We report our recent progress using a high-power, picosecond CO2 laser for Thomson scattering and ion acceleration experiments. These experiments capitalize on certain advantages of long-wavelength CO2 lasers, such as their high number of photons per energy unit and beneficial wavelength- scaling of the electrons' ponderomotive energy and critical plasma frequency. High X-ray fluxes produced in the interactions of the counter-propagating laser- and electron-beams for obtaining single-shot, high-contrast images of biological objects. The laser, focused on a hydrogen jet, generated a monoenergetic proton beam via the radiation-pressure mechanism. The energy of protons produced by this method scales linearly with the laser's intensity. We present a plan for scaling the process into the range of 100-MeV proton energy via upgrading the CO2 laser. This development will enable an advance to the laser-driven proton cancer therapy.

  19. Imaging

    International Nuclear Information System (INIS)

    Kellum, C.D.; Fisher, L.M.; Tegtmeyer, C.J.

    1987-01-01

    This paper examines the advantages of the use of excretory urography for diagnosis. According to the authors, excretory urography remains the basic radiologic examination of the urinary tract and is the foundation for the evaluation of suspected urologic disease. Despite development of the newer diagnostic modalities such as isotope scanning, ultrasonography, CT, and magnetic resonsance imaging (MRI), excretory urography has maintained a prominent role in ruorradiology. Some indications have been altered and will continue to change with the newer imaging modalities, but the initial evaluation of suspected urinary tract structural abnormalities; hematuria, pyuria, and calculus disease is best performed with excretory urography. The examination is relatively inexpensive and simple to perform, with few contraindictions. Excretory urography, when properly performed, can provide valuable information about the renal parenchyma, pelvicalyceal system, ureters, and urinary bladder

  20. Magnetic resonance imaging of the fetal brain.

    Science.gov (United States)

    Tee, L Mf; Kan, E Yl; Cheung, J Cy; Leung, W C

    2016-06-01

    This review covers the recent literature on fetal brain magnetic resonance imaging, with emphasis on techniques, advances, common indications, and safety. We conducted a search of MEDLINE for articles published after 2010. The search terms used were "(fetal OR foetal OR fetus OR foetus) AND (MR OR MRI OR [magnetic resonance]) AND (brain OR cerebral)". Consensus statements from major authorities were also included. As a result, 44 relevant articles were included and formed the basis of this review. One major challenge is fetal motion that is largely overcome by ultra-fast sequences. Currently, single-shot fast spin-echo T2-weighted imaging remains the mainstay for motion resistance and anatomical delineation. Recently, a snap-shot inversion recovery sequence has enabled robust T1-weighted images to be obtained, which is previously a challenge for standard gradient-echo acquisitions. Fetal diffusion-weighted imaging, diffusion tensor imaging, and magnetic resonance spectroscopy are also being developed. With multiplanar capabilities, superior contrast resolution and field of view, magnetic resonance imaging does not have the limitations of sonography, and can provide additional important information. Common indications include ventriculomegaly, callosum and posterior fossa abnormalities, and twin complications. There are safety concerns about magnetic resonance-induced heating and acoustic damage but current literature showed no conclusive evidence of deleterious fetal effects. The American College of Radiology guideline states that pregnant patients can be accepted to undergo magnetic resonance imaging at any stage of pregnancy if risk-benefit ratio to patients warrants that the study be performed. Magnetic resonance imaging of the fetal brain is a safe and powerful adjunct to sonography in prenatal diagnosis. It can provide additional information that aids clinical management, prognostication, and counselling.

  1. Toward brain correlates of natural behavior: fMRI during violent video games.

    Science.gov (United States)

    Mathiak, Klaus; Weber, René

    2006-12-01

    Modern video games represent highly advanced virtual reality simulations and often contain virtual violence. In a significant amount of young males, playing video games is a quotidian activity, making it an almost natural behavior. Recordings of brain activation with functional magnetic resonance imaging (fMRI) during gameplay may reflect neuronal correlates of real-life behavior. We recorded 13 experienced gamers (18-26 years; average 14 hrs/week playing) while playing a violent first-person shooter game (a violent computer game played in self-perspective) by means of distortion and dephasing reduced fMRI (3 T; single-shot triple-echo echo-planar imaging [EPI]). Content analysis of the video and sound with 100 ms time resolution achieved relevant behavioral variables. These variables explained significant signal variance across large distributed networks. Occurrence of violent scenes revealed significant neuronal correlates in an event-related design. Activation of dorsal and deactivation of rostral anterior cingulate and amygdala characterized the mid-frontal pattern related to virtual violence. Statistics and effect sizes can be considered large at these areas. Optimized imaging strategies allowed for single-subject and for single-trial analysis with good image quality at basal brain structures. We propose that virtual environments can be used to study neuronal processes involved in semi-naturalistic behavior as determined by content analysis. Importantly, the activation pattern reflects brain-environment interactions rather than stimulus responses as observed in classical experimental designs. We relate our findings to the general discussion on social effects of playing first-person shooter games. (c) 2006 Wiley-Liss, Inc.

  2. fMRI of the motor speech center using EPI