WorldWideScience

Sample records for single-pulse pump-probe laue

  1. The RATIO method for time-resolved Laue crystallography

    International Nuclear Information System (INIS)

    Coppens, P.; Pitak, M.; Gembicky, M.; Messerschmidt, M.; Scheins, S.; Benedict, J.; Adachi, S.-I.; Sato, T.; Nozawa, S.; Ichiyanagi, K.; Chollet, M.; Koshihara, S.-Y.

    2009-01-01

    A RATIO method for analysis of intensity changes in time-resolved pump-probe Laue diffraction experiments is described. The method eliminates the need for scaling the data with a wavelength curve representing the spectral distribution of the source and removes the effect of possible anisotropic absorption. It does not require relative scaling of series of frames and removes errors due to all but very short term fluctuations in the synchrotron beam.

  2. Invited Review Article: Pump-probe microscopy

    Science.gov (United States)

    Wilson, Jesse W.; Robles, Francisco E.; Warren, Warren S.

    2016-01-01

    Multiphoton microscopy has rapidly gained popularity in biomedical imaging and materials science because of its ability to provide three-dimensional images at high spatial and temporal resolution even in optically scattering environments. Currently the majority of commercial and home-built devices are based on two-photon fluorescence and harmonic generation contrast. These two contrast mechanisms are relatively easy to measure but can access only a limited range of endogenous targets. Recent developments in fast laser pulse generation, pulse shaping, and detection technology have made accessible a wide range of optical contrasts that utilize multiple pulses of different colors. Molecular excitation with multiple pulses offers a large number of adjustable parameters. For example, in two-pulse pump-probe microscopy, one can vary the wavelength of each excitation pulse, the detection wavelength, the timing between the excitation pulses, and the detection gating window after excitation. Such a large parameter space can provide much greater molecular specificity than existing single-color techniques and allow for structural and functional imaging without the need for exogenous dyes and labels, which might interfere with the system under study. In this review, we provide a tutorial overview, covering principles of pump-probe microscopy and experimental setup, challenges associated with signal detection and data processing, and an overview of applications. PMID:27036751

  3. Invited Review Article: Pump-probe microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, Martin C., E-mail: Martin.Fischer@duke.edu; Wilson, Jesse W.; Robles, Francisco E. [Department of Chemistry, Duke University, Durham, North Carolina 27708 (United States); Warren, Warren S. [Departments of Chemistry, Biomedical Engineering, Physics, and Radiology, Duke University, Durham, North Carolina 27708 (United States)

    2016-03-15

    Multiphoton microscopy has rapidly gained popularity in biomedical imaging and materials science because of its ability to provide three-dimensional images at high spatial and temporal resolution even in optically scattering environments. Currently the majority of commercial and home-built devices are based on two-photon fluorescence and harmonic generation contrast. These two contrast mechanisms are relatively easy to measure but can access only a limited range of endogenous targets. Recent developments in fast laser pulse generation, pulse shaping, and detection technology have made accessible a wide range of optical contrasts that utilize multiple pulses of different colors. Molecular excitation with multiple pulses offers a large number of adjustable parameters. For example, in two-pulse pump-probe microscopy, one can vary the wavelength of each excitation pulse, the detection wavelength, the timing between the excitation pulses, and the detection gating window after excitation. Such a large parameter space can provide much greater molecular specificity than existing single-color techniques and allow for structural and functional imaging without the need for exogenous dyes and labels, which might interfere with the system under study. In this review, we provide a tutorial overview, covering principles of pump-probe microscopy and experimental setup, challenges associated with signal detection and data processing, and an overview of applications.

  4. A Single-Pulse Integrator

    DEFF Research Database (Denmark)

    Miller, Arne

    1974-01-01

    A single-pulse integrator is described. It gives a relative measure of the integral of the output signal from a coil monitor on the Risø 10 MeV linear accelerator, and displays the value on a digital voltmeter. The reproduccibility is found to be better than ±1% for an accelerated pulse charge...

  5. Case study on the dynamics of ultrafast laser heating and ablation of gold thin films by ultrafast pump-probe reflectometry and ellipsometry

    Science.gov (United States)

    Pflug, T.; Wang, J.; Olbrich, M.; Frank, M.; Horn, A.

    2018-02-01

    To increase the comprehension of ultrafast laser ablation, the ablation process has to be portrayed with sufficient temporal resolution. For example, the temporal modification of the complex refractive index {\\tilde{n}} and the relative reflectance of a sample material after irradiation with ultrafast single-pulsed laser radiation can be measured with a pump-probe setup. This work describes the construction and validation of a pump-probe setup enabling spatially, temporally, and spectroscopically resolved Brewster angle microscopy, reflectometry, ellipsometry, and shadow photography. First pump-probe reflectometry and ellipsometry measurements are performed on gold at λ _{probe}= 440 nm and three fluences of the single-pulsed pump radiation at λ _{pump}= 800 nm generating no, gentle, and strong ablation. The relative reflectance overall increases at no and gentle ablation. At strong ablation, the relative reflectance locally decreases, presumable caused by emitted thermal electrons, ballistic electrons, and ablating material. The refractive index n is slightly decreasing after excitation, while the extinction coefficient k is increasing.

  6. Laue: right or wrong?

    International Nuclear Information System (INIS)

    Datta, Timir

    2015-01-01

    In 1912, Laue spots were discovered in x-ray scattering ‘photograms’ of crystals, which were amongst the most consequential experimental findings of the 20th century. Inter alia, spots established the x-ray waves and crystal lattice; plus, for the first time ever, revealed atoms as real physical objects. Laue, a protégé of Planck and a wave-optics expert, had theoretically predicted these spots, and promptly won the Physics Nobel Prize for 1914. The prize did not come easy: executing his experimentum cruces, over the judgments of Sommerfeld and Wien, required force of will and a certain amount of diplomacy. Besides, his explanation for missing spots and x-ray diffraction were proven wrong by Moseley, Darwin and the two Braggs. Traditionally, Laue’s three-dimensional diffraction model is reconciled with Bragg’s reflection formula by Ewald’s construction using reciprocal lattice space. Laue had overlooked that his fundamental equations violate Euclidean length invariance. This article shows that implementation of invariance consolidates Laue’s system of three (multi-parameter) equations into a single formula containing one integer, one angle and two distances; plus validating Bragg’s conjecture of reflection. This new derivation demonstrates that the mechanism of Laue spots is akin to the anti reflection coating the colour-plays in soap bubbles and oil slicks—reflection and interference not diffraction. Yet, Laue stimulated countless breakthroughs: Nobel Prizes and scientific innovations, with an enduring legacy of inspiration a century later. (invited comment)

  7. Laue: right or wrong?

    Science.gov (United States)

    Datta, Timir

    2015-03-01

    In 1912, Laue spots were discovered in x-ray scattering ‘photograms’ of crystals, which were amongst the most consequential experimental findings of the 20th century. Inter alia, spots established the x-ray waves and crystal lattice; plus, for the first time ever, revealed atoms as real physical objects. Laue, a protégé of Planck and a wave-optics expert, had theoretically predicted these spots, and promptly won the Physics Nobel Prize for 1914. The prize did not come easy: executing his experimentum cruces, over the judgments of Sommerfeld and Wien, required force of will and a certain amount of diplomacy. Besides, his explanation for missing spots and x-ray diffraction were proven wrong by Moseley, Darwin and the two Braggs. Traditionally, Laue’s three-dimensional diffraction model is reconciled with Bragg’s reflection formula by Ewald’s construction using reciprocal lattice space. Laue had overlooked that his fundamental equations violate Euclidean length invariance. This article shows that implementation of invariance consolidates Laue’s system of three (multi-parameter) equations into a single formula containing one integer, one angle and two distances; plus validating Bragg’s conjecture of reflection. This new derivation demonstrates that the mechanism of Laue spots is akin to the anti reflection coating the colour-plays in soap bubbles and oil slicks—reflection and interference not diffraction. Yet, Laue stimulated countless breakthroughs: Nobel Prizes and scientific innovations, with an enduring legacy of inspiration a century later.

  8. Time-resolved methods in biophysics. 6. Time-resolved Laue crystallography as a tool to investigate photo-activated protein dynamics.

    Science.gov (United States)

    Bourgeois, Dominique; Schotte, Friedrich; Brunori, Maurizio; Vallone, Beatrice

    2007-10-01

    When polychromatic X-rays are shined onto crystalline material, they generate a Laue diffraction pattern. At third generation synchrotron radiation sources, a single X-ray pulse of approximately 100 ps duration is enough to produce interpretable Laue data from biomolecular crystals. Thus, by initiating biological turnover in a crystalline protein, structural changes along the reaction pathway may be filmed by ultra-fast Laue diffraction. Using laser-light as a trigger, transient species in photosensitive macromolecules can be captured at near atomic resolution with sub-nanosecond time-resolution. Such pump-probe Laue experiments have now reached an outstanding level of sophistication and have found a domain of excellence in the investigation of light-sensitive proteins undergoing cyclic photo-reactions and producing stiff crystals. The main theoretical concepts of Laue diffraction and the challenges associated with time-resolved experiments on biological crystals are recalled. The recent advances in the design of experiments are presented in terms of instrumental choices, data collection strategy and data processing, and some of the inherent difficulties of the method are highlighted. The discussion is based on the example of myoglobin, a protein that has traversed the whole history of pump-probe Laue diffraction, and for which a massive amount of data have provided considerable insight into the understanding of protein dynamics.

  9. Pump probe spectroscopy of quasiparticle dynamics in cuprate superconductors

    International Nuclear Information System (INIS)

    Segre, Gino P.

    2001-01-01

    Pump probe spectroscopy is used to examine the picosecond response of a BSCCO thin film, and two YBCO crystals in the near infrared. The role of pump fluence and temperature have been closely examined in an effort to clarify the mechanism by which the quasiparticles rejoin the condensate. BSCCO results suggest that the recombination behavior is consistent with the d-wave density of states in that quasiparticles appear to relax to the nodes immediately before they rejoin the condensate. The first substantial investigation of polarized pump probe response in detwinned YBCO crystals is also reported. Dramatic doping dependent anisotropies along the a and b axes are observed in time and temperature resolved studies. Among many results, we highlight the discovery of an anomalous temperature and time dependence of a- axis response in optimally doped YBCO. We also report on the first observation of the photoinduced response in a magnetic field. We find the amplitude of the response, and in some cases, the dynamics considerably changed with the application of a 6T field. Finally, we speculate on two of the many theoretical directions stimulated by our results. We find that the two-fluid model suggests a mechanism to explain how changes at very low energies are visible to a high-energy probe. Also discussed are basic recombination processes which may play a role in the observed decay

  10. A new approach for a pump-probe photothermal experiment

    International Nuclear Information System (INIS)

    Marcano O, A.; Castillo, J.

    1992-01-01

    Calculations of the signal, observed in a pump-probe photo-thermal experimental, are performed using a close field nonlinear geometrical optics approximation. Dependence of the thermo-optical signal from the position of the detector and magnitude of the beams spots size is studied. It is shown that the possibilities of the thermo-optical experiment, as a highly sensitive technique for light detection, can be substantially improved by increasing the probe beam spot size and varying the position of the detector in the vicinity of the sample cell. preliminary experimental results are shown for the situation of weak absorbing liquids. A good qualitative agreement between theory and experiments is obtained. (author)

  11. Experimental strategies in Laue crystallography

    International Nuclear Information System (INIS)

    Clifton, I.J.; Hajdu, J.; Elder, M.

    1991-01-01

    The efficiency of data collection using the Laue technique varies with the wavelength range, the crystal symmetry, the orientation of the crystal in the X-ray beam, the crystal-to-film distance and the acceptance angle of the detector. By optimizing these parameters and by taking advantage of the diffraction symmetry represented by the Laue class, it is often possible to collect a nearly complete data set in one or two exposures. This paper discusses general strategies for data collection and presents results from a computer survey to find optimal crystal orientations for the eleven Laue classes. (orig.)

  12. Wedged multilayer Laue lens

    International Nuclear Information System (INIS)

    Conley, Ray; Liu Chian; Qian Jun; Kewish, Cameron M.; Macrander, Albert T.; Yan Hanfei; Maser, Joerg; Kang, Hyon Chol; Stephenson, G. Brian

    2008-01-01

    A multilayer Laue lens (MLL) is an x-ray focusing optic fabricated from a multilayer structure consisting of thousands of layers of two different materials produced by thin-film deposition. The sequence of layer thicknesses is controlled to satisfy the Fresnel zone plate law and the multilayer is sectioned to form the optic. An improved MLL geometry can be created by growing each layer with an in-plane thickness gradient to form a wedge, so that every interface makes the correct angle with the incident beam for symmetric Bragg diffraction. The ultimate hard x-ray focusing performance of a wedged MLL has been predicted to be significantly better than that of a nonwedged MLL, giving subnanometer resolution with high efficiency. Here, we describe a method to deposit the multilayer structure needed for an ideal wedged MLL and report our initial deposition results to produce these structures

  13. Techniques for Pump-Probe Synchronisation of Fsec Radiation Pulses

    CERN Document Server

    Schlarb, Holger

    2005-01-01

    The increasing interest on the production of ultra-short photon pulses in future generations of Free-Electron Lasers operating in the UV, VUV or X-ray regime demands new techniques to reliably measure and control the arrival time of the FEL-pulses at the experiment. For pump-probe experiments using external optical lasers the desired synchronisation is in the order of tens of femtoseconds, the typical duration of the FEL pulse. Since, the accelerators are large scale facilities of the length of several hundred meters or even kilometers, the problem of synchronisation has to be attacked twofold. First, the RF acceleration sections upstream of the magnetic bunch compressors need to be stabilised in amplitude and phase to high precision. Second, the remain electron beam timing jitter needs to be determined with femtosecond accuracy for off-line analysis. In this talk, several techniques using the electron or the FEL beam to monitor the arrival time are presented, and the proposed layout of the synchronisation sy...

  14. Time-resolved pump-probe experiments at the LCLS

    Energy Technology Data Exchange (ETDEWEB)

    Glownia, James; /SLAC /Stanford U., Appl. Phys. Dept.; Cryan, J.; /SLAC /Stanford U., Phys. Dept.; Andreasson, J.; /Uppsala U.; Belkacem, A.; /LBNL, Berkeley; Berrah, N.; /Western Michigan U.; Blaga, C.L.; /Ohio State U.; Bostedt, C.; Bozek, J.; /SLAC; DiMauro, L.F.; /Ohio State U.; Fang, L.; /Western Michigan U.; Frisch, J.; /SLAC; Gessner, O.; /LBNL; Guhr, M.; /SLAC; Hajdu, J.; /Uppsala U.; Hertlein, M.P.; /LBNL; Hoener, M.; /Western Michigan U. /LBNL; Huang, G.; Kornilov, O.; /LBNL; Marangos, J.P.; /Imperial Coll., London; March, A.M.; /Argonne; McFarland, B.K.; /SLAC /Stanford U., Phys. Dept. /SLAC /IRAMIS, Saclay /Stanford U., Phys. Dept. /Georgia Tech /Argonne /Kansas State U. /SLAC /Stanford U., Phys. Dept. /SLAC /Stanford U., Appl. Phys. Dept. /Stanford U., Appl. Phys. Dept. /SLAC /LBNL /Argonne /SLAC /SLAC /Stanford U., Appl. Phys. Dept. /Stanford U., Phys. Dept.

    2011-08-12

    The first time-resolved x-ray/optical pump-probe experiments at the SLAC Linac Coherent Light Source (LCLS) used a combination of feedback methods and post-analysis binning techniques to synchronize an ultrafast optical laser to the linac-based x-ray laser. Transient molecular nitrogen alignment revival features were resolved in time-dependent x-ray-induced fragmentation spectra. These alignment features were used to find the temporal overlap of the pump and probe pulses. The strong-field dissociation of x-ray generated quasi-bound molecular dications was used to establish the residual timing jitter. This analysis shows that the relative arrival time of the Ti:Sapphire laser and the x-ray pulses had a distribution with a standard deviation of approximately 120 fs. The largest contribution to the jitter noise spectrum was the locking of the laser oscillator to the reference RF of the accelerator, which suggests that simple technical improvements could reduce the jitter to better than 50 fs.

  15. Laue image analysis. Pt. 2

    International Nuclear Information System (INIS)

    Greenhough, T.J.; Shrive, A.K.

    1994-01-01

    Many Laue diffraction patterns from crystals of particular biological or chemical interest are of insufficient quality for their analysis to be feasible. In many cases, this is because of pronounced streaking of the spots owing to either large mosaic spread or disorder introduced during reactions in the crystal. Methods for the analysis of exposures exhibiting radial or near-radial streaking are described, along with their application in Laue diffraction studies of form-II crystals of Met-tRNA synthetase and a photosynthetic reaction centre from Rhodobacter sphaeroides. In both cases, variable elliptical radial masking has led to significant improvements in data quality and quantity and exposures that previously were too streaked to process may now be analysed. These masks can also provide circular profiles as a special case for processing high-quality Laue exposures and spatial-overlap deconvolution may be performed using the elliptical or circular masks. (orig.)

  16. Picosecond, single pulse electron linear accelerator

    International Nuclear Information System (INIS)

    Kikuchi, Riichi; Kawanishi, Masaharu

    1979-01-01

    The picosecond, single pulse electron linear accelerators, are described, which were installed in the Nuclear Engineering Laboratory of the University of Tokyo and in the Nuclear Radiation Laboratory of the Osaka University. The purpose of the picosecond, single pulse electron linear accelerators is to investigate the very short time reaction of the substances, into which gamma ray or electron beam enters. When the electrons in substances receive radiation energy, the electrons get high kinetic energy, and the energy and the electric charge shift, at last to the quasi-stable state. This transient state can be experimented with these special accelerators very accurately, during picoseconds, raising the accuracy of the time of incidence of radiation and also raising the accuracy of observation time. The outline of these picosecond, single pulse electron linear accelerators of the University of Tokyo and the Osaka University, including the history, the systems and components and the output beam characteristics, are explained. For example, the maximum energy 30 -- 35 MeV, the peak current 1 -- 8 n C, the pulse width 18 -- 40 ps, the pulse repetition rate 200 -- 720 pps, the energy spectrum 1 -- 1.8% and the output beam diameter 2 -- 5 mm are shown as the output beam characteristics of the accelerators in both universities. The investigations utilizing the picosecond single pulse electron linear accelerators, such as the investigation of short life excitation state by pulsed radiation, the dosimetry study of pulsed radiation, and the investigation of the transforming mechanism and the development of the transforming technology from picosecond, single pulse electron beam to X ray, vacuum ultraviolet ray and visual ray, are described. (Nakai, Y.)

  17. Pump-probe study of the formation of rubidium molecules by ultrafast photoassociation of ultracold atoms

    Science.gov (United States)

    McCabe, David J.; England, Duncan G.; Martay, Hugo E. L.; Friedman, Melissa E.; Petrovic, Jovana; Dimova, Emiliya; Chatel, Béatrice; Walmsley, Ian A.

    2009-09-01

    An experimental pump-probe study of the photoassociative creation of translationally ultracold rubidium molecules is presented together with numerical simulations of the process. The formation of loosely bound excited-state dimers is observed as a first step toward a fully coherent pump-dump approach to the stabilization of Rb2 into its lowest ground vibrational states. The population that contributes to the pump-probe process is characterized and found to be distinct from a background population of preassociated molecules.

  18. In vivo pump-probe microscopy of melanoma and pigmented lesions

    Science.gov (United States)

    Wilson, Jesse W.; Degan, Simone; Mitropoulos, Tanya; Selim, M. Angelica; Zhang, Jennifer Y.; Warren, Warren S.

    2012-03-01

    A growing number of dermatologists and pathologists are concerned that the rapidly rising incidence of melanoma reflects not a true 'epidemic' but an increasing tendency to overdiagnose pigmented lesions. Addressing this problem requires both a better understanding of early-stage melanoma and new diagnostic criteria based on more than just cellular morphology and architecture. Here we present a method for in-vivo optical microscopy that utilizes pump-probe spectroscopy to image the distribution of the two forms of melanin in skin: eumelanin and pheomelanin. Images are acquired in a scanning microscope with a sensitive modulation transfer technique by analyzing back-scattered probe light with a lock-in amplifier. Early-stage melanoma is studied in a human skin xenografted mouse model. Individual melanocytes have been observed, in addition to pigmented keratinocytes. Combining the pump-probe images simultaneously with other noninvasive laser microscopy methods (confocal reflectance, multiphoton autofluorescence, and second harmonic generation) allows visualization of the skin architecture, framing the functional pump-probe image in the context of the surrounding tissue morphology. It is found that pump-probe images of melanin can be acquired with low peak intensities, enabling wide field-of-view pigmentation surveys. Finally, we investigate the diagnostic potential of the additional chemical information available from pump-probe microscopy.

  19. Self triggered single pulse beam position monitor

    International Nuclear Information System (INIS)

    Rothman, J.L.; Blum, E.B.

    1993-01-01

    A self triggered beam position monitor (BPM) has been developed for the NSLS injection system to provide single pulse orbit measurements in the booster synchrotron, linac, and transport lines. The BPM integrates the negative going portion of 3 nS wide bipolar pickup electrode signals. The gated, self triggering feature confines critical timing components to the front end, relaxing external timing specifications. The system features a low noise high speed FET sampler, a fiber optic gate for bunch and turn selection, and an inexpensive interface to a standard PC data acquisition system

  20. ALADIN - Advanced Laue Diffraction Instruments using Neutrons

    International Nuclear Information System (INIS)

    Lemee-Cailleau, M.H.; Ouladdiaf, B.; McIntyre, G.J.

    2011-01-01

    Laue diffraction techniques have proven to be very attractive to a broad user community interested in obtaining detailed structural information on very small single-crystal samples or needing data collection speeds comparable to those available with the powder diffraction technique. However our experience has clearly demonstrated the negative effect of up-stream monochromatic instruments on the quality of Laue data. In order to obtain Laue diffraction data with a statistical accuracy similar to that achieved on a monochromatic instrument (neutron or X-rays), the project ALADIN (for Advanced Laue Diffraction Instruments using Neutrons) aims to: -) construct a Laue-dedicated thermal neutron guide, with m=2 super-mirror coating, providing access to the desirable wavelength bandwidth; -) installation of one of the ILL Laue diffractometers (VIVALDI or CYCLOPS) on this new guide. (authors)

  1. Pump-probe experiments in atoms involving laser and synchrotron radiation: an overview

    International Nuclear Information System (INIS)

    Wuilleumier, F J; Meyer, M

    2006-01-01

    The combined use of laser and synchrotron radiations for atomic photoionization studies started in the early 1980s. The strong potential of these pump-probe experiments to gain information on excited atomic states is illustrated through some exemplary studies. The first series of experiments carried out with the early synchrotron sources, from 1960 to about 1995, are reviewed, including photoionization of unpolarized and polarized excited atoms, and time-resolved laser-synchrotron studies. With the most advanced generation of synchrotron sources, a whole new class of pump-probe experiments benefiting from the high brightness of the new synchrotron beams has been developed since 1996. A detailed review of these studies as well as possible future applications of pump-probe experiments using third generation synchrotron sources and free electron lasers is presented. (topical review)

  2. High Speed Pump-Probe Apparatus for Observation of Transitional Effects in Ultrafast Laser Micromachining Processes

    Directory of Open Access Journals (Sweden)

    Ilya Alexeev

    2015-12-01

    Full Text Available A pump-probe experimental approach has been shown to be a very efficient tool for the observation and analysis of various laser matter interaction effects. In those setups, synchronized laser pulses are used to create an event (pump and to simultaneously observe it (probe. In general, the physical effects that can be investigated with such an apparatus are restricted by the temporal resolution of the probe pulse and the observation window. The latter can be greatly extended by adjusting the pump-probe time delay under the assumption that the interaction process remains fairly reproducible. Unfortunately, this assumption becomes invalid in the case of high-repetition-rate ultrafast laser material processing, where the irradiation history strongly affects the ongoing interaction process. In this contribution, the authors present an extension of the pump-probe setup that allows to investigate transitional and dynamic effects present during ultrafast laser machining performed at high pulse repetition frequencies.

  3. Frequency-resolved pump-probe characterization of femtosecond infrared pulses

    NARCIS (Netherlands)

    Yeremenko, S.; Baltuška, A.; Haan, F. de; Pshenichnikov, M.S.; Wiersma, D.A.

    2002-01-01

    A novel method for ultrashort IR pulse characterization is presented. The technique utilizes a frequency-resolved pump-probe geometry that is common in applications of ultrafast spectroscopy, without any modifications of the setup. The experimental demonstration of the method was carried out to

  4. Pump-probe surface photovoltage spectroscopy measurements on semiconductor epitaxial layers

    International Nuclear Information System (INIS)

    Jana, Dipankar; Porwal, S.; Sharma, T. K.; Oak, S. M.; Kumar, Shailendra

    2014-01-01

    Pump-probe Surface Photovoltage Spectroscopy (SPS) measurements are performed on semiconductor epitaxial layers. Here, an additional sub-bandgap cw pump laser beam is used in a conventional chopped light geometry SPS setup under the pump-probe configuration. The main role of pump laser beam is to saturate the sub-bandgap localized states whose contribution otherwise swamp the information related to the bandgap of material. It also affects the magnitude of Dember voltage in case of semi-insulating (SI) semiconductor substrates. Pump-probe SPS technique enables an accurate determination of the bandgap of semiconductor epitaxial layers even under the strong influence of localized sub-bandgap states. The pump beam is found to be very effective in suppressing the effect of surface/interface and bulk trap states. The overall magnitude of SPV signal is decided by the dependence of charge separation mechanisms on the intensity of the pump beam. On the contrary, an above bandgap cw pump laser can be used to distinguish the signatures of sub-bandgap states by suppressing the band edge related feature. Usefulness of the pump-probe SPS technique is established by unambiguously determining the bandgap of p-GaAs epitaxial layers grown on SI-GaAs substrates, SI-InP wafers, and p-GaN epilayers grown on Sapphire substrates

  5. Analysis of femtosecond pump-probe photoelectron-photoion coincidence measurements applying Bayesian probability theory

    Science.gov (United States)

    Rumetshofer, M.; Heim, P.; Thaler, B.; Ernst, W. E.; Koch, M.; von der Linden, W.

    2018-06-01

    Ultrafast dynamical processes in photoexcited molecules can be observed with pump-probe measurements, in which information about the dynamics is obtained from the transient signal associated with the excited state. Background signals provoked by pump and/or probe pulses alone often obscure these excited-state signals. Simple subtraction of pump-only and/or probe-only measurements from the pump-probe measurement, as commonly applied, results in a degradation of the signal-to-noise ratio and, in the case of coincidence detection, the danger of overrated background subtraction. Coincidence measurements additionally suffer from false coincidences, requiring long data-acquisition times to keep erroneous signals at an acceptable level. Here we present a probabilistic approach based on Bayesian probability theory that overcomes these problems. For a pump-probe experiment with photoelectron-photoion coincidence detection, we reconstruct the interesting excited-state spectrum from pump-probe and pump-only measurements. This approach allows us to treat background and false coincidences consistently and on the same footing. We demonstrate that the Bayesian formalism has the following advantages over simple signal subtraction: (i) the signal-to-noise ratio is significantly increased, (ii) the pump-only contribution is not overestimated, (iii) false coincidences are excluded, (iv) prior knowledge, such as positivity, is consistently incorporated, (v) confidence intervals are provided for the reconstructed spectrum, and (vi) it is applicable to any experimental situation and noise statistics. Most importantly, by accounting for false coincidences, the Bayesian approach allows us to run experiments at higher ionization rates, resulting in a significant reduction of data acquisition times. The probabilistic approach is thoroughly scrutinized by challenging mock data. The application to pump-probe coincidence measurements on acetone molecules enables quantitative interpretations

  6. Synchronized and configurable source of electrical pulses for x-ray pump-probe experiments

    International Nuclear Information System (INIS)

    Strachan, J. P.; Chembrolu, V.; Yu, X. W.; Tyliszczak, T.; Acremann, Y.

    2007-01-01

    A method is described for the generation of software tunable patterns of nanosecond electrical pulses. The bipolar, high repetition rate (up to 250 MHz), fast rise time (<30 ps), square pulses are suitable for applications such as the excitation sequence in dynamic pump-probe experiments. Synchronization with the time structure of a synchrotron facility is possible as well as fine control of the relative delay in steps of 10 ps. The pulse generator described here is used to excite magnetic nanostructures with current pulses. Having an excitation system which can match the high repetition rate of a synchrotron allows for utilization of the full x-ray flux and is needed in experiments which require a large photon flux. The fast rise times allow for picosecond time resolution in pump-probe experiments. All pulse pattern parameters are configurable by software

  7. Heterodyne pump probe measurements of nonlinear dynamics in an indium phosphide photonic crystal cavity

    DEFF Research Database (Denmark)

    Heuck, Mikkel; Combrié, S.; Lehoucq, G.

    2013-01-01

    Using a sensitive two-color heterodyne pump-probe technique, we investigate the carrier dynamics of an InP photonic crystal nanocavity. The heterodyne technique provides unambiguous results for all wavelength configurations, including the degenerate case, which cannot be investigated with the wid......Using a sensitive two-color heterodyne pump-probe technique, we investigate the carrier dynamics of an InP photonic crystal nanocavity. The heterodyne technique provides unambiguous results for all wavelength configurations, including the degenerate case, which cannot be investigated...... with the widely used homodyne technique. A model based on coupled mode theory including two carrier distributions is introduced to account for the relaxation dynamics, which is assumed to be governed by both diffusion and recombination....

  8. Detecting strain wave propagation through quantum dots by pump-probe spectroscopy: A theoretical analysis

    International Nuclear Information System (INIS)

    Huneke, J; Kuhn, T; Axt, V M

    2010-01-01

    The influence of strain waves traveling across a quantum dot structure on its optical response is studied for two different situations: First, a strain wave is created by the optical excitation of a single quantum dot near a surface which, after reflection at the surface, reenters the dot; second, a phonon wave packet is emitted by the excitation of a nearby second dot and then travels across the quantum dot. Pump-probe type excitations are simulated for quantum dots in the strong confinement limit. We show that the optical signals allow us to monitor crossing strain waves for both structures in the real-time response as well as in the corresponding pump-probe spectra. In the time-derivative of the phase of the polarization a distinct trace reflects the instantaneous shifts of the transition energy during the passage while in the spectra pronounced oscillations reveal the passage of the strain waves.

  9. Laue 2007: international workshop on advanced Laue diffraction in frontier science

    International Nuclear Information System (INIS)

    Adachi, S.I.; Akgul, G.; Aksoy, F.; Andersen, K.; Andersson, M.; Anfinrud, Ph.; Baruchel, J.; Bastie, P.; Bau, R.; Blakeley, M.; Bourgeois, D.; Brau, D.; Bravin, A.; Cammarata, M.; Christensen, M.; Cole, J.; Courtois, P.; Cousson, A.; Eggonopoulos-Papadopoulos, B.; Daoud-Aladine, M.A.; Dera, P.; Feng, R.; Fiedler, St.; Fischer, H.; Fisher, St.; Folami, S.; Fosu, M.A.; Fuente, F.; Fullagar, W.; Fulla Marsa, D.; Ghosh, R.; Giles, C.; Goossens, D.; Goujon, A.; Gutmann, M.; Heger, G.; Henry, E.; Hewat, A.; Hossmann, Ch.; Ivanov, A.; Jauch, W.; Jorgensen, R.; Katona, G.; Keen, D.; Kong, Q.; Koshihara, Sh.Y.; Lauss, B.; Laue, M.V.; Lecomte, C.; Legrand, V.; Lemee-Cailleau, M.H.; Marmeggi, J.C.; Martinez-Criado, G.; Mason, S.; McIntyre, G.; Mailleur, F.; Micha, J.S.; Moffat, K.; Mohammed Mustapha, A.; Ouladdiaf, B.; Pahl, R.; Parise, J.; Pearson, A.; Pecaut, J.; Popov, A.; Prokleska, J.; Raitman, E.; Ren, Z.; Rodriguez-Carvajal, J.; Sasaki, J.; Schmidt, M.; Schotte, F.; Stirling, W.; Suominen Fuller, M.; Tanaka, I.; Timmins, P.; Tomking, P.; Turner, M.; Van Thor, J.; Vettier, Ch.; Wildes, A.; Wilson, Ch.; Wohri, A.; Wulf, M.; Zhao, Y.

    2007-01-01

    Laue diffraction is currently undergoing a lively renaissance due to new instrumental developments at both synchrotron X-ray and neutron sources. The aim of the workshop Laue-2007 is to offer state-of-the-art experimental methods and hands-on experience of data analysis for exploration, using single-crystal Laue diffraction, of the crystalline structure of complex materials in extreme cases. The oral sessions cover the following topics: -) history and renaissance of Laue diffraction, -) modern X-ray techniques, -) modern neutron techniques, -) applications, -) analysis and software demonstrations including hands-on experience, and -) future directions. This document gathers the abstracts of the presentations and of the posters

  10. Laue 2007: international workshop on advanced Laue diffraction in frontier science

    Energy Technology Data Exchange (ETDEWEB)

    Adachi, S I; Akgul, G; Aksoy, F; Andersen, K; Andersson, M; Anfinrud, Ph; Baruchel, J; Bastie, P; Bau, R; Blakeley, M; Bourgeois, D; Brau, D; Bravin, A; Cammarata, M; Christensen, M; Cole, J; Courtois, P; Cousson, A; Eggonopoulos-Papadopoulos, B; Daoud-Aladine, M A; Dera, P; Feng, R; Fiedler, St; Fischer, H; Fisher, St; Folami, S; Fosu, M A; Fuente, F; Fullagar, W; Fulla Marsa, D; Ghosh, R; Giles, C; Goossens, D; Goujon, A; Gutmann, M; Heger, G; Henry, E; Hewat, A; Hossmann, Ch; Ivanov, A; Jauch, W; Jorgensen, R; Katona, G; Keen, D; Kong, Q; Koshihara, Sh Y; Lauss, B; Laue, M V; Lecomte, C; Legrand, V; Lemee-Cailleau, M H; Marmeggi, J C; Martinez-Criado, G; Mason, S; McIntyre, G; Mailleur, F; Micha, J S; Moffat, K; Mohammed Mustapha, A; Ouladdiaf, B; Pahl, R; Parise, J; Pearson, A; Pecaut, J; Popov, A; Prokleska, J; Raitman, E; Ren, Z; Rodriguez-Carvajal, J; Sasaki, J; Schmidt, M; Schotte, F; Stirling, W; Suominen Fuller, M; Tanaka, I; Timmins, P; Tomking, P; Turner, M; Van Thor, J; Vettier, Ch; Wildes, A; Wilson, Ch; Wohri, A; Wulf, M; Zhao, Y

    2007-07-01

    Laue diffraction is currently undergoing a lively renaissance due to new instrumental developments at both synchrotron X-ray and neutron sources. The aim of the workshop Laue-2007 is to offer state-of-the-art experimental methods and hands-on experience of data analysis for exploration, using single-crystal Laue diffraction, of the crystalline structure of complex materials in extreme cases. The oral sessions cover the following topics: -) history and renaissance of Laue diffraction, -) modern X-ray techniques, -) modern neutron techniques, -) applications, -) analysis and software demonstrations including hands-on experience, and -) future directions. This document gathers the abstracts of the presentations and of the posters.

  11. Controlling the optical bistability and multistability in a two-level pumped-probe system

    International Nuclear Information System (INIS)

    Mahmoudi, Mohammad; Sahrai, Mostafa; Masoumeh Mousavi, Seyede

    2010-01-01

    We study the behavior of the optical bistability (OB) and multistability (OM) in a two-level pumped-probe atomic system by means of a unidirectional ring cavity. We show that the optical bistability in a two-level atomic system can be controlled by adjusting the intensity of the pump field and the detuning between two fields. We find that applying the pumping field decreases the threshold of the optical bistability.

  12. Dynamic characterization of silicon nanowires using a terahertz optical asymmetric demultiplexer-based pump-probe scheme

    DEFF Research Database (Denmark)

    Ji, Hua; Cleary, C. S.; Dailey, J. M.

    2012-01-01

    Dynamic phase and amplitude all-optical responses of silicon nanowires are characterized using a terahertz optical asymmetric demultiplexer (TOAD) based pump-probe scheme. Ultra-fast recovery is observed for moderate pump powers....

  13. Diagnosis and staging of female genital tract melanocytic lesions using pump-probe microscopy (Conference Presentation)

    Science.gov (United States)

    Robles, Francisco E.; Selim, Maria A.; Warren, Warren S.

    2016-02-01

    Melanoma of the vulva is the second most common type of malignancy afflicting that organ. This disease caries poor prognosis, and shows tendencies to recur locally and develop distant metastases through hematogenous dissemination. Further, there exists significant clinical overlap between early-stage melanomas and melanotic macules, benign lesions that are believed to develop in about 10% of the general female population. In this work we apply a novel nonlinear optical method, pump-probe microscopy, to quantitatively analyze female genitalia tract melanocytic lesions. Pump-probe microscopy provides chemical information of endogenous pigments by probing their electronic excited state dynamics, with subcellular resolution. Using unstained biopsy sections from 31 patients, we find significant differences between melanin type and structure in tissue regions with invasive melanoma, melanoma in-situ and non-malignant melanocytic proliferations (e.g., nevi, melanocytic macules). The molecular images of non-malignant lesion have a well-organized structure, with relatively homogenous pigment chemistry, most often consistent with that of eumelanin with large aggregate size or void of metals, such as iron. On the other hand, pigment type and structure observed in melanomas in-situ and invasive melanomas is typically much more heterogeneous, with larger contributions from pheomelanin, melanins with larger metal content, and/or melanins with smaller aggregate size. Of most significance, clear differences can be observed between melanocytic macules and vulvar melanoma in-situ, which, as discussed above, can be difficult to clinically distinguish. This initial study demonstrates pump-probe microscopy's potential as an adjuvant diagnostic tool by revealing systematic chemical and morphological differences in melanin pigmentation among invasive melanoma, melanoma in-situ and non-malignant melanocytic lesions.

  14. Anomalous phase behavior and apparent anharmonicity of the pump-probe signal in a two-dimensional harmonic potential system

    International Nuclear Information System (INIS)

    Taneichi, T.; Kobayashi, T.

    2007-01-01

    Discussion on wavelength dependent 'anharmonic' effects in a pump-probe signal for a system of wavepacket on one- and two-dimensional harmonic potentials was given. The Fourier power spectrum of the signal, calculated for a model composed of a three-state electronic system coupled to a set of displaced harmonic oscillators, depends on the pulse duration. Condition under which the wavepacket motion in the harmonic potential substantially deviates from that of the classical point mass is derived. The Fourier power spectrum has enhanced components with frequencies of harmonics even in a system composed of ideally harmonic potentials. Utility of the Fourier analysis of the spectrum for clarification of the squeezed molecular vibrational state is discussed. Calculated oscillatory behavior in phase of a pump-probe signal, as a function of probe frequency, was discussed in terms of a two-dimensional effect on a pump-probe signal

  15. A two-parameter nondiffusive heat conduction model for data analysis in pump-probe experiments

    Science.gov (United States)

    Ma, Yanbao

    2014-12-01

    Nondiffusive heat transfer has attracted intensive research interests in last 50 years because of its importance in fundamental physics and engineering applications. It has unique features that cannot be described by the Fourier law. However, current studies of nondiffusive heat transfer still focus on studying the effective thermal conductivity within the framework of the Fourier law due to a lack of a well-accepted replacement. Here, we show that nondiffusive heat conduction can be characterized by two inherent material properties: a diffusive thermal conductivity and a ballistic transport length. We also present a two-parameter heat conduction model and demonstrate its validity in different pump-probe experiments. This model not only offers new insights of nondiffusive heat conduction but also opens up new avenues for the studies of nondiffusive heat transfer outside the framework of the Fourier law.

  16. Probing Dynamics in Colloidal Crystals with Pump-Probe Experiments at LCLS: Methodology and Analysis

    Directory of Open Access Journals (Sweden)

    Nastasia Mukharamova

    2017-05-01

    Full Text Available We present results of the studies of dynamics in colloidal crystals performed by pump-probe experiments using an X-ray free-electron laser (XFEL. Colloidal crystals were pumped with an infrared laser at a wavelength of 800 nm with varying power and probed by XFEL pulses at an energy of 8 keV with a time delay up to 1000 ps. The positions of the Bragg peaks, and their radial and azimuthal widths were analyzed as a function of the time delay. The spectral analysis of the data did not reveal significant enhancement of frequencies expected in this experiment. This allowed us to conclude that the amplitude of vibrational modes excited in colloidal crystals was less than the systematic error caused by the noise level.

  17. Real-time ultrafast dynamics of dense, hot matter measured by pump-probe Doppler spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Lad, Amit D; Mondal, S; Narayanan, V; Ahmed, Saima; Kumar, G Ravindra; Rajeev, P P; Robinson, A P L [Central Laser Facility, Rutherford-Appleton Laboratory, Chilton, Oxfordshire (United Kingdom); Pasley, J, E-mail: amitlad@tifr.res.i [Department of Physics, University of York, Heslington, York (United Kingdom)

    2010-08-01

    A detailed understanding of the critical surface motion of high intensity laser produced plasma is very crucial for understanding the interaction. We employ the two colour pump-probe technique to report the first ever femtosecond scale ultrafast dynamics measurement of the critical surface of a solid plasma produced by a relativistically intense, femtosecond pump laser beam (10{sup 18} W/cm{sup 2}, 30 fs, 800 nm) on an aluminium target. We observe the Doppler shift of a time delayed probe laser beam (10{sup 12} W/cm{sup 2}, 80 fs, 400 nm) up to delays of 30 ps. Such unravelling of dynamics has not been possible in earlier measurements, which typically used the self reflection of a powerful pump pulse. We observe time dependent red and blue shifts and measure their magnitudes to infer plasma expansion velocity and acceleration and thereby the plasma profile. Our results are very well reproduced by 1D hydrodynamic simulation (HYADES code).

  18. Effective temporal resolution in pump-probe spectroscopy with strongly chirped pulses

    International Nuclear Information System (INIS)

    Polli, D.; Lanzani, G.; Brida, D.; Cerullo, G.; Mukamel, S.

    2010-01-01

    This paper introduces a general theoretical description of femtosecond pump-probe spectroscopy with chirped pulses whose joint spectral and temporal profile is expressed by Wigner spectrograms. We demonstrate that the actual experimental time resolution intimately depends on the pulse-sample interaction and that the commonly used instrumental response function needs to be replaced by a sample-dependent effective response function. We also show that, using the proper configurations in excitation and/or detection, it is possible to overcome the temporal smearing of the measured dynamics due to chirp-induced pulse broadening and recover the temporal resolution that would be afforded by the transform-limited pulses. We verify these predictions with experiments using broadband chirped pump and probe pulses. Our results allow optimization of the temporal resolution in the common case when the chirp of the pump and/or probe pulse is not corrected and may be extended to a broad range of time-resolved experiments.

  19. Energy transfer in isolated LHC II studied by femtosecond pump-probe technique

    CERN Document Server

    Yang Yi; Liu Yuan; Liu Wei Min; Zhu Rong Yi; Qian Shi Xiong; Xu Chun He

    2003-01-01

    Excitation energy transfer in the isolated light-harvesting chlorophyll (Chl)-a/b protein complex of photosystem II (LHC II) was studied by the one-colour pump-probe technique with femtosecond time resolution. After exciting Chl-b by 638nm beam, the dynamic behaviour shows that the ultrafast energy transfer from Chl-b at positions of B2, B3, and B5 to the corresponding Chl-a molecules in monomeric subunit of LHC II is in the time scale of 230fs. While with the excitation of Chl-a at 678nm, the energy transfer between excitons of Chl-a molecules has the lifetime of about 370 fs, and two other slow decay components are due to the energy transfer between different Chl-a molecules in a monomeric subunit of LHC II or in different subunits, or due to change of molecular conformation. (20 refs).

  20. Detection of hydrodynamic expansion in ultrashort pulse laser ellipsometric pump-probe experiments

    International Nuclear Information System (INIS)

    Morikami, Hidetoshi; Yoneda, Hitoki; Ueda, Ken-ichi; More, Richard M.

    2004-01-01

    In ultrashort-pulse laser interaction with solid target materials, the target rapidly heats, melts, evaporates, and begins to expand as a vapor or plasma. The onset of hydrodynamic expansion following surface evaporation is a switching point, where the dominant physics changes from temperature dependence of the solid dielectric function to refraction by the dense vapor cloud. We propose and demonstrate a method to analyze reflection data to identify this onset of target expansion. We use two of the Stokes parameters obtained from ellipsometric pump-probe measurements to determine a dielectric function with an assumption of no expansion. We use this dielectric function to predict the full set of reflectivity measurements. If there is a sharply defined target interface, this method reproduces the experimental data. When the plasma expansion is no longer negligible, the prediction deviates from the experimental measurements. This comparison shows when the plasma expansion is no longer negligible

  1. Determination of hot carrier energy distributions from inversion of ultrafast pump-probe reflectivity measurements.

    Science.gov (United States)

    Heilpern, Tal; Manjare, Manoj; Govorov, Alexander O; Wiederrecht, Gary P; Gray, Stephen K; Harutyunyan, Hayk

    2018-05-10

    Developing a fundamental understanding of ultrafast non-thermal processes in metallic nanosystems will lead to applications in photodetection, photochemistry and photonic circuitry. Typically, non-thermal and thermal carrier populations in plasmonic systems are inferred either by making assumptions about the functional form of the initial energy distribution or using indirect sensors like localized plasmon frequency shifts. Here we directly determine non-thermal and thermal distributions and dynamics in thin films by applying a double inversion procedure to optical pump-probe data that relates the reflectivity changes around Fermi energy to the changes in the dielectric function and in the single-electron energy band occupancies. When applied to normal incidence measurements our method uncovers the ultrafast excitation of a non-Fermi-Dirac distribution and its subsequent thermalization dynamics. Furthermore, when applied to the Kretschmann configuration, we show that the excitation of propagating plasmons leads to a broader energy distribution of electrons due to the enhanced Landau damping.

  2. Near shot-noise limited time-resolved circular dichroism pump-probe spectrometer

    Science.gov (United States)

    Stadnytskyi, Valentyn; Orf, Gregory S.; Blankenship, Robert E.; Savikhin, Sergei

    2018-03-01

    We describe an optical near shot-noise limited time-resolved circular dichroism (TRCD) pump-probe spectrometer capable of reliably measuring circular dichroism signals in the order of μdeg with nanosecond time resolution. Such sensitivity is achieved through a modification of existing TRCD designs and introduction of a new data processing protocol that eliminates approximations that have caused substantial nonlinearities in past measurements and allows the measurement of absorption and circular dichroism transients simultaneously with a single pump pulse. The exceptional signal-to-noise ratio of the described setup makes the TRCD technique applicable to a large range of non-biological and biological systems. The spectrometer was used to record, for the first time, weak TRCD kinetics associated with the triplet state energy transfer in the photosynthetic Fenna-Matthews-Olson antenna pigment-protein complex.

  3. High-mechanical-strength single-pulse draw tower gratings

    Science.gov (United States)

    Rothhardt, Manfred W.; Chojetzki, Christoph; Mueller, Hans Rainer

    2004-11-01

    The inscription of fiber Bragg gratings during the drawing process is a very useful method to realize sensor arrays with high numbers of gratings and excellent mechanical strength and also type II gratings with high temperature stability. Results of single pulse grating arrays with numbers up to 100 and definite wavelengths and positions for sensor applications were achieved at 1550 nm and 830 nm using new photosensitive fibers developed in IPHT. Single pulse type I gratings at 1550 nm with more than 30% reflectivity were shown first time to our knowledge. The mechanical strength of this fiber with an Ormocer coating with those single pulse gratings is the same like standard telecom fibers. Weibull plots of fiber tests will be shown. At 830 nm we reached more than 10% reflectivity with single pulse writing during the fiber drawing in photosensitive fibers with less than 16 dB/km transmission loss. These gratings are useful for stress and vibration sensing applications. Type II gratings with reflectivity near 100% and smooth spectral shape and spectral width of about 1 nm are temperature stable up to 1200 K for short time. They are also realized in the fiber drawing process. These gratings are useful for temperature sensor applications.

  4. Automation Enhancement of Multilayer Laue Lenses

    Energy Technology Data Exchange (ETDEWEB)

    Lauer K. R.; Conley R.

    2010-12-01

    X-ray optics fabrication at Brookhaven National Laboratory has been facilitated by a new, state of the art magnetron sputtering physical deposition system. With its nine magnetron sputtering cathodes and substrate carrier that moves on a linear rail via a UHV brushless linear servo motor, the system is capable of accurately depositing the many thousands of layers necessary for multilayer Laue lenses. I have engineered a versatile and automated control program from scratch for the base system and many subsystems. Its main features include a custom scripting language, a fully customizable graphical user interface, wireless and remote control, and a terminal-based interface. This control system has already been successfully used in the creation of many types of x-ray optics, including several thousand layer multilayer Laue lenses.Before reaching the point at which a deposition can be run, stencil-like masks for the sputtering cathodes must be created to ensure the proper distribution of sputtered atoms. Quality of multilayer Laue lenses can also be difficult to measure, given the size of the thin film layers. I employ my knowledge of software and algorithms to further ease these previously painstaking processes with custom programs. Additionally, I will give an overview of an x-ray optic simulator package I helped develop during the summer of 2010. In the interest of keeping my software free and open, I have worked mostly with the multiplatform Python and the PyQt application framework, utilizing C and C++ where necessary.

  5. Single Hit Energy-resolved Laue Diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Shamim; Suggit, Matthew J.; Stubley, Paul G.; Ciricosta, Orlando; Wark, Justin S.; Higginbotham, Andrew [Clarendon Laboratory, Department of Physics, University of Oxford, Parks Road, Oxford OX1 3PU (United Kingdom); Hawreliak, James A.; Collins, Gilbert W.; Eggert, Jon H. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Comley, Andrew J.; Foster, John M. [Atomic Weapons Establishment, Aldermaston, Reading RG7 4PR (United Kingdom)

    2015-05-15

    In situ white light Laue diffraction has been successfully used to interrogate the structure of single crystal materials undergoing rapid (nanosecond) dynamic compression up to megabar pressures. However, information on strain state accessible via this technique is limited, reducing its applicability for a range of applications. We present an extension to the existing Laue diffraction platform in which we record the photon energy of a subset of diffraction peaks. This allows for a measurement of the longitudinal and transverse strains in situ during compression. Consequently, we demonstrate measurement of volumetric compression of the unit cell, in addition to the limited aspect ratio information accessible in conventional white light Laue. We present preliminary results for silicon, where only an elastic strain is observed. VISAR measurements show the presence of a two wave structure and measurements show that material downstream of the second wave does not contribute to the observed diffraction peaks, supporting the idea that this material may be highly disordered, or has undergone large scale rotation.

  6. Single Hit Energy-resolved Laue Diffraction

    International Nuclear Information System (INIS)

    Patel, Shamim; Suggit, Matthew J.; Stubley, Paul G.; Ciricosta, Orlando; Wark, Justin S.; Higginbotham, Andrew; Hawreliak, James A.; Collins, Gilbert W.; Eggert, Jon H.; Comley, Andrew J.; Foster, John M.

    2015-01-01

    In situ white light Laue diffraction has been successfully used to interrogate the structure of single crystal materials undergoing rapid (nanosecond) dynamic compression up to megabar pressures. However, information on strain state accessible via this technique is limited, reducing its applicability for a range of applications. We present an extension to the existing Laue diffraction platform in which we record the photon energy of a subset of diffraction peaks. This allows for a measurement of the longitudinal and transverse strains in situ during compression. Consequently, we demonstrate measurement of volumetric compression of the unit cell, in addition to the limited aspect ratio information accessible in conventional white light Laue. We present preliminary results for silicon, where only an elastic strain is observed. VISAR measurements show the presence of a two wave structure and measurements show that material downstream of the second wave does not contribute to the observed diffraction peaks, supporting the idea that this material may be highly disordered, or has undergone large scale rotation

  7. Resolution enhancement of pump-probe microscope with an inverse-annular filter

    Science.gov (United States)

    Kobayashi, Takayoshi; Kawasumi, Koshi; Miyazaki, Jun; Nakata, Kazuaki

    2018-04-01

    Optical pump-probe microscopy can provide images by detecting changes in probe light intensity induced by stimulated emission, photoinduced absorbance change, or photothermal-induced refractive index change in either transmission or reflection mode. Photothermal microscopy, which is one type of optical pump-probe microscopy, has intrinsically super resolution capability due to the bilinear dependence of signal intensity of pump and probe. We introduce new techniques for further resolution enhancement and fast imaging in photothermal microscope. First, we introduce a new pupil filter, an inverse-annular pupil filter in a pump-probe photothermal microscope, which provides resolution enhancement in three dimensions. The resolutions are proved to be improved in lateral and axial directions by imaging experiment using 20-nm gold nanoparticles. The improvement in X (perpendicular to the common pump and probe polarization direction), Y (parallel to the polarization direction), and Z (axial direction) are by 15 ± 6, 8 ± 8, and 21 ± 2% from the resolution without a pupil filter. The resolution enhancement is even better than the calculation using vector field, which predicts the corresponding enhancement of 11, 8, and 6%. The discussion is made to explain the unexpected results. We also demonstrate the photothermal imaging of thick biological samples (cells from rabbit intestine and kidney) stained with hematoxylin and eosin dye with the inverse-annular filter. Second, a fast, high-sensitivity photothermal microscope is developed by implementing a spatially segmented balanced detection scheme into a laser scanning microscope using a Galvano mirror. We confirm a 4.9 times improvement in signal-to-noise ratio in the spatially segmented balanced detection compared with that of conventional detection. The system demonstrates simultaneous bi-modal photothermal and confocal fluorescence imaging of transgenic mouse brain tissue with a pixel dwell time of 20 µs. The

  8. Pump-probe study of atoms and small molecules with laser driven high order harmonics

    Science.gov (United States)

    Cao, Wei

    A commercially available modern laser can emit over 1015 photons within a time window of a few tens of femtoseconds (10-15second), which can be focused into a spot size of about 10 mum, resulting in a peak intensity above 1014W/cm2. This paves the way for table-top strong field physics studies such as above threshold ionization (ATI), non-sequential double ionization (NSDI), high order harmonic generation (HHG), etc.. Among these strong laser-matter interactions, high order harmonic generation, which combines many photons of the fundamental laser field into a single photon, offers a unique way to generate light sources in the vacuum ultraviolet (VUV) or extreme ultraviolet (EUV) region. High order harmonic photons are emitted within a short time window from a few tens of femtoseconds down to a few hundreds of attoseconds (10 -18second). This highly coherent nature of HHG allows it to be synchronized with an infrared (IR) laser pulse, and the pump-probe technique can be adopted to study ultrafast dynamic processes in a quantum system. The major work of this thesis is to develop a table-top VUV(EUV) light source based on HHG, and use it to study dynamic processes in atoms and small molecules with the VUV(EUV)-pump IR-probe method. A Cold Target Recoil Ion Momentum Spectroscopy (COLTRIMS) apparatus is used for momentum imaging of the interaction products. Two types of high harmonic pump pulses are generated and applied for pump-probe studies. The first one consists of several harmonics forming a short attosecond pulse train (APT) in the EUV regime (around 40 eV). We demonstrate that, (1) the auto-ionization process triggered by the EUV in cation carbon-monoxide and oxygen molecules can be modified by scanning the EUV-IR delay, (2) the phase information of quantum trajectories in bifurcated high harmonics can be extracted by performing an EUV-IR cross-correlation experiment, thus disclosing the macroscopic quantum control in HHG. The second type of high harmonic source

  9. Helium nanodroplets. Pump-probe ionization of alkali dopings and spin-echo scattering on undoped drops; Helium-Nanotroepfchen. Pump-Probe-Ionisation von Alkalidotierungen und Spinechostreuung an undotierten Tropfen

    Energy Technology Data Exchange (ETDEWEB)

    Droppelmann, G.

    2005-09-15

    In the framework of this thesis several aspects of the properties of helium nanodroplets and their dopings. The formation of the exciplexes RbHe and KHe on helium droplets was studied by means of pump-probe ionization in real time, whereby the main interest lied on the influence of the applied helium isotopes. The experiments with cesium atoms on the droplet surface aimed on the elucidation of the relaxation dynamics of the surface under regardment both of isotope and size effects. From the pump-probe measurements on the formation of the exciplex RbHe on helium nanodroplets performed in the framework of this thesis formation times of 8.5 ps for Rb{sup 4}He and 11.6 ps for Rb{sup 3}He resulted.

  10. Infrared-x-ray pump-probe spectroscopy of the NO molecule

    International Nuclear Information System (INIS)

    Guimaraes, F.F.; Felicissimo, V.C.; Kimberg, V.; Gel'mukhanov, F.; Aagren, H.; Cesar, A.

    2005-01-01

    Two color infrared-x-ray pump-probe spectroscopy of the NO molecule is studied theoretically and numerically in order to obtain a deeper insight of the underlying physics and of the potential of this suggested technology. From the theoretical investigation a number of conclusions could be drawn: It is found that the phase of the infrared field strongly influences the trajectory of the nuclear wave packet, and hence, the x-ray spectrum. The trajectory experiences fast oscillations with the vibrational frequency with a modulation due to the anharmonicity of the potential. The dependences of the x-ray spectra on the delay time, the duration, and the shape of the pulses are studied in detail. It is shown that the x-ray spectrum keep memory about the infrared phase after the pump field left the system. This memory effect is sensitive to the time of switching-off the pump field and the Rabi frequency. The phase effect takes maximum value when the duration of the x-ray pulse is one-fourth of the infrared field period, and can be enhanced by a proper control of the duration and intensity of the pump pulse. The manifestation of the phase is different for oriented and disordered molecules and depends strongly on the intensity of the pump radiation

  11. Femtosecond pump-probe studies of phonons and carriers in bismuth under high pressure

    International Nuclear Information System (INIS)

    Kasami, M.; Ogino, T.; Mishina, T.; Yamamoto, S.; Nakahara, J.

    2006-01-01

    We investigate the high-pressure phase of Bi under hydrostatic pressure using pump-probe spectroscopy at pressures up to 3.0 GPa, and we observe coherent phonons signal and relaxation signal of photo-excited carriers at Bi(II) and Bi(III) phases. The pressure dependence of the coherent phonons shows that the amplitude of coherent phonons is extremely small and the frequency of coherent phonons changes at high-pressure phases. As results from our experiment, we obtain its frequencies are 2.5 and 2.2 THz at Bi(II) and Bi(III), respectively. Furthermore, photo-excited carrier relaxation indicates drastic changes near 2.5 GPa. Bismuth transforms from semimetal to semiconductor near 2.5 GPa, and band-overlapping between at L-point and at T-point disappears. We consider that the drastic changes of the photo-excited carrier relaxation are strongly correlated with the band-overlapping disappearing

  12. Infrared x-ray pump-probe spectroscopy of the NO molecule

    Science.gov (United States)

    Guimarães, F. F.; Kimberg, V.; Felicíssimo, V. C.; Gel'Mukhanov, F.; Cesar, A.; Ågren, H.

    2005-07-01

    Two color infrared x-ray pump-probe spectroscopy of the NO molecule is studied theoretically and numerically in order to obtain a deeper insight of the underlying physics and of the potential of this suggested technology. From the theoretical investigation a number of conclusions could be drawn: It is found that the phase of the infrared field strongly influences the trajectory of the nuclear wave packet, and hence, the x-ray spectrum. The trajectory experiences fast oscillations with the vibrational frequency with a modulation due to the anharmonicity of the potential. The dependences of the x-ray spectra on the delay time, the duration, and the shape of the pulses are studied in detail. It is shown that the x-ray spectrum keep memory about the infrared phase after the pump field left the system. This memory effect is sensitive to the time of switching-off the pump field and the Rabi frequency. The phase effect takes maximum value when the duration of the x-ray pulse is one-fourth of the infrared field period, and can be enhanced by a proper control of the duration and intensity of the pump pulse. The manifestation of the phase is different for oriented and disordered molecules and depends strongly on the intensity of the pump radiation.

  13. Pump-probe studies of travelling coherent longitudinal acoustic phonon oscillations in GaAs

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Y.; Qi, J.; Tolk, Norman [Department of Physics and Astronomy, Vanderbilt University, Nashville, TN, 37235 (United States); Miller, J. [Naval air Warfare Center Weapons Division, China Lake, CA 93555 (United States); Cho, Y.J.; Liu, X.; Furdyna, J.K. [Department of Physics, University of Notre Dame, Notre Dame, IN 46556 (United States); Shahbazyan, T.V. [Department of Physics, Jackson State University, MS 39217 (United States)

    2008-07-01

    We report comprehensive studies of long-lived oscillations in femtosecond optical pump-probe measurements on GaAs based systems. The oscillations arise from a photo-generated coherent longitudinal acoustic phonon wave at the sample surface, which subsequently travels from the surface into the GaAs substrate, thus providing information on the optical properties of the material as a function of time/depth. Wavelength-dependent studies of the oscillations near the bandgap of GaAs indicate strong correlations to the optical properties of GaAs. We also use the coherent longitudinal acoustic phonon waves to probe a thin buried Ga{sub 0.1}In{sub 0.9}As layers non-invasively. The observed phonon oscillations experience a reduction in amplitude and a phase change at wavelengths near the bandgap of the GaAs, when it passes through the thin Ga{sub x}In{sub 1-x}As layer. The layer depth and thicknesses can be extracted from the oscillation responses. A model has been developed that satisfactorily characterizes the experimental results. (copyright 2008 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  14. Ultrafast carrier dynamics in bilayer graphene studied by broadband infrared pump-probe spectroscopy

    Science.gov (United States)

    Limmer, Thomas; da Como, Enrico; Niggebaum, Alexander; Feldmann, Jochen

    2010-03-01

    Recently, bilayer graphene gained a large interest because of its electrically tunable gap appearing in the middle infrared part of the electromagnetic spectrum. This feature is expected to open a number of applications of bilayer graphene in optoelectronics. In this communication we report on the first pump-probe experiment on a single bilayer flake with an unprecedented probe photon energy interval (0.25 -- 1.3 eV). Single flakes were prepared by mechanical exfoliation of graphite and transferred to calcium fluoride substrates. When illuminated with 800 nm (1.5 eV) pump pulses the induced change in transmission shows an ultrafast saturation of the interband transitions from 1.3 to 0.5 eV. In this energy range the saturation recovery occurs within 3 ps and is consistent with an ultrafast relaxation of hot carriers. Interestingly, we report on the observation of a resonance at 0.4 eV characterized by a longer dynamics. The results are discussed considering many-body interactions.

  15. Thirteen pump-probe resonances of the sodium D1 line

    International Nuclear Information System (INIS)

    Wong, Vincent; Boyd, Robert W.; Stroud, C. R. Jr.; Bennink, Ryan S.; Marino, Alberto M.

    2003-01-01

    We present the results of a pump-probe laser spectroscopic investigation of the Doppler-broadened sodium D1 resonance line. We find 13 resonances in the resulting spectra. These observations are well described by the numerical predictions of a four-level atomic model of the hyperfine structure of the sodium D1 line. We also find that many, but not all, of these features can be understood in terms of processes originating in a two-level or three-level subset of the full four-level model. The processes we observed include forward near-degenerate four-wave mixing and saturation in a two-level system, difference-frequency crossing and nondegenerate four-wave mixing in a three-level V system, electromagnetically induced transparency and optical pumping in a three-level lambda system, cross-transition resonance in a four-level double-lambda system, and conventional optical pumping. Most of these processes lead to sub-Doppler or even subnatural linewidths. The dependence of these resonances on the pump intensity and pump detuning from atomic resonance are also studied

  16. A bent Laue-Laue monochromator for a synchrotron-based computed tomography system

    CERN Document Server

    Ren, B; Chapman, L D; Ivanov, I; Wu, X Y; Zhong, Z; Huang, X

    1999-01-01

    We designed and tested a two-crystal bent Laue-Laue monochromator for wide, fan-shaped synchrotron X-ray beams for the program multiple energy computed tomography (MECT) at the National Synchrotron Light Source (NSLS). MECT employs monochromatic X-ray beams from the NSLS's X17B superconducting wiggler beamline for computed tomography (CT) with an improved image quality. MECT uses a fixed horizontal fan-shaped beam with the subject's apparatus rotating around a vertical axis. The new monochromator uses two Czochralski-grown Si crystals, 0.7 and 1.4 mm thick, respectively, and with thick ribs on their upper and lower ends. The crystals are bent cylindrically, with the axis of the cylinder parallel to the fan beam, using 4-rod benders with two fixed rods and two movable ones. The bent-crystal feature of the monochromator resolved the difficulties we had had with the flat Laue-Laue design previously used in MECT, which included (a) inadequate beam intensity, (b) excessive fluctuations in beam intensity, and (c) i...

  17. Two-color pump-probe laser spectroscopy instrument with picosecond time-resolved electronic delay and extended scan range

    Science.gov (United States)

    Yu, Anchi; Ye, Xiong; Ionascu, Dan; Cao, Wenxiang; Champion, Paul M.

    2005-11-01

    An electronically delayed two-color pump-probe instrument was developed using two synchronized laser systems. The instrument has picosecond time resolution and can perform scans over hundreds of nanoseconds without the beam divergence and walk-off effects that occur using standard spatial delay systems. A unique picosecond Ti :sapphire regenerative amplifier was also constructed without the need for pulse stretching and compressing optics. The picosecond regenerative amplifier has a broad wavelength tuning range, which suggests that it will make a significant contribution to two-color pump-probe experiments. To test this instrument we studied the rotational correlation relaxation of myoglobin (τr=8.2±0.5ns) in water as well as the geminate rebinding kinetics of oxygen to myoglobin (kg1=1.7×1011s-1, kg2=3.4×107s-1). The results are consistent with, and improve upon, previous studies.

  18. Femtosecond resolution timing jitter correction on a TW scale Ti:sapphire laser system for FEL pump-probe experiments.

    Science.gov (United States)

    Csatari Divall, Marta; Mutter, Patrick; Divall, Edwin J; Hauri, Christoph P

    2015-11-16

    Intense ultrashort pulse lasers are used for fs resolution pump-probe experiments more and more at large scale facilities, such as free electron lasers (FEL). Measurement of the arrival time of the laser pulses and stabilization to the machine or other sub-systems on the target, is crucial for high time-resolution measurements. In this work we report on a single shot, spectrally resolved, non-collinear cross-correlator with sub-fs resolution. With a feedback applied we keep the output of the TW class Ti:sapphire amplifier chain in time with the seed oscillator to ~3 fs RMS level for several hours. This is well below the typical pulse duration used at FELs and supports fs resolution pump-probe experiments. Short term jitter and long term timing drift measurements are presented. Applicability to other wavelengths and integration into the timing infrastructure of the FEL are also covered to show the full potential of the device.

  19. Femtosecond pump probe spectroscopy for the study of energy transfer of light-harvesting complexes from extractions of spinach leaves

    Directory of Open Access Journals (Sweden)

    L. van Rensburg

    2010-01-01

    Full Text Available Measurements of ultrafast transient processes, of temporal durations in the picosecond and femtosecond regime, are made possible by femtosecond pump probe transient absorption spectroscopy. Such an ultrafast pump probe transient absorption setup has been implemented at the CSIR National Laser Centre and has been applied to investigate energy transfer processes in different parts of photosynthetic systems. In this paper we report on our first results obtained with Malachite green as a benchmark. Malachite green was chosen because the lifetime of its excited state is well known. We also present experimental results of the ultrafast energy transfer of light-harvesting complexes in samples prepared from spinach leaves. Various pump wavelengths in the range 600–680 nm were used; the probe was a white light continuum spanning 420–700 nm. The experimental setup is described in detail in this paper. Results obtained with these samples are consistent with those expected and achieved by other researchers in this field.

  20. User oriented end-station on VUV pump-probe magneto-optical ellipsometry at ELI beamlines

    Science.gov (United States)

    Espinoza, Shirly; Neuber, Gerd; Brooks, Christopher D.; Besner, Bastian; Hashemi, Maryam; Rübhausen, Michael; Andreasson, Jakob

    2017-11-01

    A state of the art ellipsometer for user operations is being implemented at ELI Beamlines in Prague, Czech Republic. It combines three of the most promising and exotic forms of ellipsometry: VUV, pump-probe and magneto-optical ellipsometry. This new ellipsometer covers a spectral operational range from the NIR up to the VUV, with high through-put between 1 and 40 eV. The ellipsometer also allows measurements of magneto-optical spectra with a 1 kHz switchable magnetic field of up to 1.5 T across the sample combining ellipsometry and Kerr spectroscopy measurements in an unprecedented spectral range. This form of generalized ellipsometry enables users to address diagonal and off-diagonal components of the dielectric tensor within one measurement. Pump-probe measurements enable users to study the dynamic behaviour of the dielectric tensor in order to resolve the time-domain phenomena in the femto to 100 ns range.

  1. Vibrational dynamics of adsorbed molecules under conditions of photodesorption: Pump-probe SFG spectra of CO/Pt(111)

    Science.gov (United States)

    Fournier, Frédéric; Zheng, Wanquan; Carrez, Serge; Dubost, Henri; Bourguignon, Bernard

    2004-09-01

    Interaction of CO adsorbed on Pt(111) with electrons and phonons is studied experimentally by means of a pump-probe experiment where CO is probed by IR+visible sum frequency generation under a pump laser intensity that allows photodesorption. Vibrational spectra of CO internal stretch are obtained as a function of pump-probe delay. A two-temperature and anharmonic coupling model is used to extract from the spectra the real time variations of CO peak frequency and dephasing time. The main conclusions are the following: (i) The CO stretch is perturbed by two low-frequency modes, assigned to frustrated rotation and frustrated translation. (ii) The frustrated rotation is directly coupled to electrons photoexcited in Pt(111) by the pump laser. (iii) There is no evidence of Pt-CO stretch excitation in the spectra. The implications for the photodesorption dynamics are discussed.

  2. Heterodyne pump-probe and four-wave mixing in semiconductor optical amplifiers using balanced lock-in detection

    DEFF Research Database (Denmark)

    Borri, Paola; Langbein, Wolfgang; Mørk, Jesper

    1999-01-01

    We demonstrate a new detection scheme for pump-probe and four-wave mixing heterodyne experiments, using balanced detection and a dual-phase lock-in for spectral filtering. The technique allows the use of low repetition-rate laser systems, as is demonstrated on an InGaAsP/InP bulk optical amplifier...... at 1.53 mym. Ultrafast pump-induced changes in the amplitude and phase of the transmitted probe signal are simultaneously measured, going from small to large signal changes and with no need of an absolute phase calibration, showing the versatility and the sensitivity of this detection scheme....... The results for small perturbations are consistent with previous pump-probe experiments reported in literature. Time-resolved four-wave mixing in the absorption regime of the device is measured, and compared with numerical simulations, indicating a 100 fs dephasing time....

  3. Helium nanodroplets. Pump-probe ionization of alkali dopings and spin-echo scattering on undoped drops

    International Nuclear Information System (INIS)

    Droppelmann, G.

    2005-09-01

    In the framework of this thesis several aspects of the properties of helium nanodroplets and their dopings. The formation of the exciplexes RbHe and KHe on helium droplets was studied by means of pump-probe ionization in real time, whereby the main interest lied on the influence of the applied helium isotopes. The experiments with cesium atoms on the droplet surface aimed on the elucidation of the relaxation dynamics of the surface under regardment both of isotope and size effects. From the pump-probe measurements on the formation of the exciplex RbHe on helium nanodroplets performed in the framework of this thesis formation times of 8.5 ps for Rb 4 He and 11.6 ps for Rb 3 He resulted

  4. Jitter-correction for IR/UV-XUV pump-probe experiments at the FLASH free-electron laser

    International Nuclear Information System (INIS)

    Savelyev, Evgeny; Boll, Rebecca; Bomme, Cedric; Schirmel, Nora; Redlin, Harald

    2017-01-01

    In pump-probe experiments employing a free-electron laser (FEL) in combination with a synchronized optical femtosecond laser, the arrival-time jitter between the FEL pulse and the optical laser pulse often severely limits the temporal resolution that can be achieved. Here, we present a pump-probe experiment on the UV-induced dissociation of 2,6-difluoroiodobenzene C 6 H 3 F 2 I) molecules performed at the FLASH FEL that takes advantage of recent upgrades of the FLASH timing and synchronization system to obtain high-quality data that are not limited by the FEL arrival-time jitter. Here, we discuss in detail the necessary data analysis steps and describe the origin of the time-dependent effects in the yields and kinetic energies of the fragment ions that we observe in the experiment.

  5. Institut Max von Laue-Paul Langevin

    International Nuclear Information System (INIS)

    This part of the annual report is concerned with the external and internal organization of the ILL (Institut Laue-Langevin), and a general presentation of the activities of the ILL during 1975. A first part is concerned with measurement and control instruments: three axis spectrometers,, time-of-flight, crystallography, diffuse scattering, powder spectrometers, polarized neutrons, monochromators, nuclear physics. In the second part the fields of research are reviewed by College: theory, nuclear physics, excitations, structures, liquids, gas and amorphous materials, imperfections, physical biochemistry, and chemistry, reactor exploitation [fr

  6. Institut Max von Laue-Paul Langevin

    International Nuclear Information System (INIS)

    Whereas the first volume of the Annual Report gives a general survey of the activities of the different sections of the ILL (Institut Laue-Langevin), this second volume titled Annex to the 1975 annual report is dealing in more details with the scientific work carried out at the ILL from November the 1st 1974 to October the 1st 1975. Scientific works for which reports are available are presented grouped as possible, by college: theory; nuclear physics; excitations; structures; liquids, gas and amorphous materials; imperfections; physical biochemistry; and chemistry [fr

  7. Detritiation plant of the Laue Longevin Institute

    International Nuclear Information System (INIS)

    Pautrot, P.; Arnaud, J.P.

    The detritiation plant at the Laue Longevin Institute, which is to serve the double function of detritiation and reconcentration of heavy water in the high flux reactor (HFR) is described. The process effected in this unit combines a catalytic exchange between heavy water and deuterium and a distillation of liquid deuterium. Placed in operation at the end of 1971, this installation processed heavy water from the HFR from the beginning of 1972, maintaining an isotopic concentration above 99.6 percent and a tritium activity below 2 Ci/liter. Exceptionally satisfactory performance now permits also processing of tritiated heavy water from external sources

  8. Label-Free Imaging of Female Genital Tract Melanocytic Lesions With Pump-Probe Microscopy: A Promising Diagnostic Tool.

    Science.gov (United States)

    Robles, Francisco E; Deb, Sanghamitra; Fischer, Martin C; Warren, Warren S; Selim, Maria Angelica

    2017-04-01

    Melanomas of the female genital tract present a unique clinical challenge. Not only are these lesions in an anatomically sensitive area, but also they tend to be multifocal and have high recurrence rates. Furthermore, several benign melanocytic proliferations resemble early-stage melanoma clinically and/or histopathologically. Thus, there is a significant need for additional tools that can help correctly diagnose and stage these lesions. Here, we quantitatively and nondestructively analyze the chemical composition of melanin in excised pigmented lesions of the female genital tract using pump-probe microscopy, a high-resolution optical imaging technique that is sensitive to many biochemical properties of melanin. Thirty-one thin (~5 μm) tissue sections previously excised from female genital tract melanocytic lesions were imaged with pump-probe microscopy and analyzed. We find significant quantitative differences in melanin type and structure between melanoma and nonmalignant melanocytic proliferations. Our analysis also suggests a link between the molecular signatures of melanins and lesion-specific genetic mutations. Finally, significant differences are found between metastatic and nonmetastatic melanomas. The limitations of this work include the fact that molecular information is restricted to melanin pigment and the sample size is relatively small. Pump-probe microscopy provides unique information regarding the biochemical composition of genital tract melanocytic lesions, which can be used to improve the diagnosis and staging of vulvar melanomas.

  9. Time-resolved pump-probe X-ray absorption fine structure spectroscopy of Gaq3

    International Nuclear Information System (INIS)

    Dicke, Benjamin

    2013-01-01

    Gallium(tris-8-hydroxyquinoline) (Gaq 3 ) belongs to a class of metal organic compounds, used as electron transport layer and emissive layer in organic light emitting diodes. Many research activities have concentrated on the optical and electronic properties, especially of the homologue molecule aluminum(tris-8-hydroxyquinoline) (Alq 3 ). Knowledge of the first excited state S 1 structure of these molecules could provide deeper insight into the processes involved into the operation of electronic devices, such as OLEDs and, hence, it could further improve their efficiency and optical properties. Until now the excited state structure could not be determined experimentally. Most of the information about this structure mainly arises from theoretical calculations. X-ray absorption fine structure (XAFS) spectroscopy is a well developed technique to determine both, the electronic and the geometric properties of a sample. The connection of ultrashort pulsed X-ray sources with a pulsed laser system offers the possibility to use XAFS as a tool for studying the transient changes of a sample induced by a laser pulse. In the framework of this thesis a new setup for time-resolved pump-probe X-ray absorption spectroscopy at PETRA III beamline P11 was developed for measuring samples in liquid form. In this setup the sample is pumped into its photo-excited state by a femtosecond laser pump pulse with 343 nm wavelength and after a certain time delay probed by an X-ray probe pulse. In this way the first excited singlet state S 1 of Gaq 3 dissolved in benzyl alcohol was analyzed. A structural model for the excited state structure of the Gaq 3 molecule based on the several times reproduced results of the XAFS experiments is proposed. According to this model it was found that the Ga-N A bond length is elongated, while the Ga-O A bond length is shortened upon photoexcitation. The dynamics of the structural changes were not the focus of this thesis. Nevertheless the excited state lifetime

  10. Time zero determination for FEL pump-probe studies based on ultrafast melting of bismuth

    Directory of Open Access Journals (Sweden)

    S. W. Epp

    2017-09-01

    Full Text Available A common challenge for pump-probe studies of structural dynamics at X-ray free-electron lasers (XFELs is the determination of time zero (T0—the time an optical pulse (e.g., an optical laser arrives coincidently with the probe pulse (e.g., a XFEL pulse at the sample position. In some cases, T0 might be extracted from the structural dynamics of the sample's observed response itself, but generally, an independent robust method is required or would be superior to the inferred determination of T0. In this paper, we present how the structural dynamics in ultrafast melting of bismuth can be exploited for a quickly performed, reliable and accurate determination of T0 with a precision below 20 fs and an overall experimental accuracy of 50 fs to 150 fs (estimated. Our approach is potentially useful and applicable for fixed-target XFEL experiments, such as serial femtosecond crystallography, utilizing an optical pump pulse in the ultraviolet to near infrared spectral range and a pixelated 2D photon detector for recording crystallographic diffraction patterns in transmission geometry. In comparison to many other suitable approaches, our method is fairly independent of the pumping wavelength (UV–IR as well as of the X-ray energy and offers a favorable signal contrast. The technique is exploitable not only for the determination of temporal characteristics of the experiment at the interaction point but also for investigating important conditions affecting experimental control such as spatial overlap and beam spot sizes.

  11. Ultra-Broadband Two-Dimensional Electronic Spectroscopy and Pump-Probe Microscopy of Molecular Systems

    Science.gov (United States)

    Spokoyny, Boris M.

    Ultrafast spectroscopy offers an unprecedented view on the dynamic nature of chemical reactions. From charge transfer in semiconductors to folding and isomerization of proteins, these all important processes can now be monitored and in some instances even controlled on real, physical timescales. One of the biggest challenges of ultrafast science is the incredible energetic complexity of most systems. It is not uncommon to encounter macromolecules or materials with absorption spectra spanning significant portions of the visible spectrum. Monitoring a multitude of electronic and vibrational transitions, all dynamically interacting with each other on femtosecond timescales poses a truly daunting experimental task. The first part of this thesis deals with the development of a novel Two-Dimensional Electronic Spectroscopy (2DES) and its associated, advanced detection methodologies. Owing to its ultra-broadband implementation, this technique enables us to monitor femtosecond chemical dynamics that span the energetic landscape of the entire visible spectrum. In order to demonstrate the utility of our method, we apply it to two laser dye molecules, IR-144 and Cresyl Violet. Variation of photophysical properties on a microscopic scale in either man-made or naturally occurring systems can have profound implications on how we understand their macroscopic properties. Recently, inorganic hybrid perovskites have been tapped as the next generation solar energy harvesting materials. Their remarkable properties include low exciton binding energy, low exciton recombination rates and long carrier diffusion lengths. Nevertheless, considerable variability in device properties made with nearly identical preparation methods has puzzled the community. In the second part of this thesis we use non-linear pump probe microscopy to study the heterogeneous nature of femtosecond carrier dynamics in thin film perovskites. We show that the local morphology of the perovskite thin films has a

  12. Time zero determination for FEL pump-probe studies based on ultrafast melting of bismuth.

    Science.gov (United States)

    Epp, S W; Hada, M; Zhong, Y; Kumagai, Y; Motomura, K; Mizote, S; Ono, T; Owada, S; Axford, D; Bakhtiarzadeh, S; Fukuzawa, H; Hayashi, Y; Katayama, T; Marx, A; Müller-Werkmeister, H M; Owen, R L; Sherrell, D A; Tono, K; Ueda, K; Westermeier, F; Miller, R J D

    2017-09-01

    A common challenge for pump-probe studies of structural dynamics at X-ray free-electron lasers (XFELs) is the determination of time zero (T 0 )-the time an optical pulse (e.g., an optical laser) arrives coincidently with the probe pulse (e.g., a XFEL pulse) at the sample position. In some cases, T 0 might be extracted from the structural dynamics of the sample's observed response itself, but generally, an independent robust method is required or would be superior to the inferred determination of T 0 . In this paper, we present how the structural dynamics in ultrafast melting of bismuth can be exploited for a quickly performed, reliable and accurate determination of T 0 with a precision below 20 fs and an overall experimental accuracy of 50 fs to 150 fs (estimated). Our approach is potentially useful and applicable for fixed-target XFEL experiments, such as serial femtosecond crystallography, utilizing an optical pump pulse in the ultraviolet to near infrared spectral range and a pixelated 2D photon detector for recording crystallographic diffraction patterns in transmission geometry. In comparison to many other suitable approaches, our method is fairly independent of the pumping wavelength (UV-IR) as well as of the X-ray energy and offers a favorable signal contrast. The technique is exploitable not only for the determination of temporal characteristics of the experiment at the interaction point but also for investigating important conditions affecting experimental control such as spatial overlap and beam spot sizes.

  13. Development of an X-ray delay unit for correlation spectroscopy and pump-probe experiments

    Energy Technology Data Exchange (ETDEWEB)

    Roseker, Wojciech

    2008-07-15

    Probing condensed matter on time scales ranging from femtoseconds to nanoseconds will be one of the key topics for future X-ray Free Electron Laser (XFEL) sources. The accessible time windows are, however, compromised by the intrinsic time structure of the sources. One way to overcome this limitation is the usage of a time delay unit. A prototype device capable of splitting an X-ray pulse into two adjustable fractions, delaying one of them with the aim to perform X-ray Photon Correlation Spectroscopy and pump-probe type studies was designed and manufactured. The device utilizes eight perfect crystals in vertical 90 scattering geometry. Its performance has been verified with 8.39 keV and 12.4 keV Xrays at various synchrotron sources. The measured throughput of the device with a Si(333) monochromator at 8.39 keV under ambient conditions is 0.6%. The stability was verified at 12.4 keV and operation without realignment and feedback was possible for more than 30 minutes. Time delays up to 2.95 ns have been achieved. The highest resolution achieved in an experiment was 15.4 ps, a value entirely determined by the diagnostics system. The influence of the delay unit optics on the coherence properties of the beam was investigated by means of Fraunhofer diffraction and static speckle analysis. The obtained high fringe visibility and contrast values larger than 23% indicate the feasibility of performing coherence based experiments with the delay line. (orig.)

  14. Dispersion cancellation in a triple Laue interferometer

    International Nuclear Information System (INIS)

    Lemmel, Hartmut

    2014-01-01

    The concept of dispersion cancellation has been established in light optics to improve the resolution of interferometric measurements on dispersive media. Odd order dispersion cancellation allows to measure phase shifts without defocusing the interferometer due to wave packet displacements, while even order dispersion cancellation allows to measure time lags without losing resolution due to wave packet spreading. We report that either type of dispersion cancellation can be realized very easily in a triple Laue interferometer. Such interferometers are Mach–Zehnder interferometers based on Bragg diffraction, and are commonly used for neutrons and x-rays. Although the first x-ray interferometer was built nearly five decades ago, the feature of dispersion cancellation hasn't been recognized so far because the concept was hardly known in the neutron and x-ray community. However, it explains right away the surprising decoupling of phase shift and spatial displacement that we have discovered recently in neutron interferometry (Lemmel and Wagh 2010 Phys. Rev. A 82 033626). Furthermore, this article might inspire the light optics community to consider whether a triple Laue interferometer for laser light would be useful and feasible. We explain how dispersion cancellation works in neutron interferometry, and we describe the setup rigorously by solving the Schrödinger equation and by calculating the path integral. We point out, that the latter has to be evaluated with special care since in our setup the beam trajectory moves with respect to the crystal lattice of the interferometer. (paper)

  15. An electro-optical timing diagnostic for pump-probe experiments at the free-electron laser in Hamburg FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Azima, Armin

    2009-07-15

    Femtosecond pump-probe experiments have extensively been used to follow atomic and molecular motion in time. The very intense extreme ultraviolet XUV light of the Free electron LASer in Hamburg FLASH facility allows to investigate fundamental processes such as direct one or few photon inner shell ionizations. A supplementary Ti:Sapphire near infrared femtosecond laser system allows to perform two-color pump-probe experiments with FLASH involving intense laser fields of hugely different photon energies. Within this work a bunch arrival measurement system has been built, which assists these two-color pump-probe experiments to reduce the temporal jitter of FLASH and to increase the temporal resolution. The diagnostic is based upon an electro-optical detection scheme and measures the relative arrival time between the Ti:Sapphire femtosecond pulse and the electron bunch, which generates the self-amplified by stimulated emission SASE XUV pulse in the undulator section of FLASH. Key feature of the diagnostic is a 150 m long glass fiber pulse transport line, which inflicts non-linear dispersion. A dispersion control system to compensate for this higher order dispersion has been developed including the control and programming of a spatial light phase modulator. It was possible to transport a 90 fs FWHM short near infrared femtosecond laser pulse Fourier limited by the dispersion compensated glass fiber. The electro-optical signal induced by the FLASH electron bunch was generated, characterized and optimized. The signal features beside the designated bunch arrival timing capability the additional possibility to measure the longitudinal electron bunch density distribution of an arbitrary bunch of FLASH in a single shot with a temporal resolution of below 100 fs RMS. Timing and bunch analysis capabilities of the developed diagnostic have been cross-checked with other comparable diagnostics at FLASH like the transversal deflecting cavity structure named LOLA. Finally, the

  16. An electro-optical timing diagnostic for pump-probe experiments at the free-electron laser in Hamburg FLASH

    International Nuclear Information System (INIS)

    Azima, Armin

    2009-07-01

    Femtosecond pump-probe experiments have extensively been used to follow atomic and molecular motion in time. The very intense extreme ultraviolet XUV light of the Free electron LASer in Hamburg FLASH facility allows to investigate fundamental processes such as direct one or few photon inner shell ionizations. A supplementary Ti:Sapphire near infrared femtosecond laser system allows to perform two-color pump-probe experiments with FLASH involving intense laser fields of hugely different photon energies. Within this work a bunch arrival measurement system has been built, which assists these two-color pump-probe experiments to reduce the temporal jitter of FLASH and to increase the temporal resolution. The diagnostic is based upon an electro-optical detection scheme and measures the relative arrival time between the Ti:Sapphire femtosecond pulse and the electron bunch, which generates the self-amplified by stimulated emission SASE XUV pulse in the undulator section of FLASH. Key feature of the diagnostic is a 150 m long glass fiber pulse transport line, which inflicts non-linear dispersion. A dispersion control system to compensate for this higher order dispersion has been developed including the control and programming of a spatial light phase modulator. It was possible to transport a 90 fs FWHM short near infrared femtosecond laser pulse Fourier limited by the dispersion compensated glass fiber. The electro-optical signal induced by the FLASH electron bunch was generated, characterized and optimized. The signal features beside the designated bunch arrival timing capability the additional possibility to measure the longitudinal electron bunch density distribution of an arbitrary bunch of FLASH in a single shot with a temporal resolution of below 100 fs RMS. Timing and bunch analysis capabilities of the developed diagnostic have been cross-checked with other comparable diagnostics at FLASH like the transversal deflecting cavity structure named LOLA. Finally, the

  17. Theoretical Simulations and Ultrafast Pump-probe Spectroscopy Experiments in Pigment-protein Photosynthetic Complexes

    Energy Technology Data Exchange (ETDEWEB)

    Buck, D. R. [Iowa State Univ., Ames, IA (United States)

    2000-09-12

    Theoretical simulations and ultrafast pump-probe laser spectroscopy experiments were used to study photosynthetic pigment-protein complexes and antennae found in green sulfur bacteria such as Prosthecochloris aestuarii, Chloroflexus aurantiacus, and Chlorobium tepidum. The work focused on understanding structure-function relationships in energy transfer processes in these complexes through experiments and trying to model that data as we tested our theoretical assumptions with calculations. Theoretical exciton calculations on tubular pigment aggregates yield electronic absorption spectra that are superimpositions of linear J-aggregate spectra. The electronic spectroscopy of BChl c/d/e antennae in light harvesting chlorosomes from Chloroflexus aurantiacus differs considerably from J-aggregate spectra. Strong symmetry breaking is needed if we hope to simulate the absorption spectra of the BChl c antenna. The theory for simulating absorption difference spectra in strongly coupled photosynthetic antenna is described, first for a relatively simple heterodimer, then for the general N-pigment system. The theory is applied to the Fenna-Matthews-Olson (FMO) BChl a protein trimers from Prosthecochloris aestuarii and then compared with experimental low-temperature absorption difference spectra of FMO trimers from Chlorobium tepidum. Circular dichroism spectra of the FMO trimer are unusually sensitive to diagonal energy disorder. Substantial differences occur between CD spectra in exciton simulations performed with and without realistic inhomogeneous distribution functions for the input pigment diagonal energies. Anisotropic absorption difference spectroscopy measurements are less consistent with 21-pigment trimer simulations than 7-pigment monomer simulations which assume that the laser-prepared states are localized within a subunit of the trimer. Experimental anisotropies from real samples likely arise from statistical averaging over states with diagonal energies shifted by

  18. Ultrafast pump-probe spectroscopy of Zinc Phthalocynine (ZnPc) and light harvesting complex II (LHC II)

    CSIR Research Space (South Africa)

    Ombinda-Lemboumba, Saturnin

    2009-07-01

    Full Text Available pump-probe spectroscopy of Zinc Phthalocynine (ZnPc) and light harvesting complex II (LHC II) SAIP 7-10 July 2009, University of Kwazulu Natal. S. Ombinda-Lemboumba1, 2 A. du Plessis1, L. Botha1, D.E. Roberts1, P. Molukanele1, 3, R.W. Sparrow3, E... and phtobiology (2008) Page 12 Conclusion SAIP 7-10 July 2009, University of Kwazulu natal Femto group © CSIR 2008 www.csir.co.za • Presented our method of correcting chirp induced by white light generation. • Pump...

  19. LAUE lens development at UC Berkeley: status and prospects

    Science.gov (United States)

    Barrière, Nicolas M.; Tomsick, John A.; Ackermann, Marcelo D.; Bastie, Pierre; Boggs, Steven E.; Hanlon, Lorraine; Jentschel, Michael; Lowell, Alexander; Roudil, Gilles; von Ballmoos, Peter; Wade, Colin

    2013-09-01

    We report on the status of the Laue lens development effort led by UC Berkeley, where a dedicated X-ray beamline and a Laue lens assembly station were built. This allowed the realization of a first lens prototype in June 2012. Based on this achievement, and thanks to a new NASA APRA grant, we are moving forward to enable Laue lenses. Several parallel activities are in progress. Firstly, we are refining the method to glue quickly and accurately crystals on a lens substrate. Secondly, we are conducting a study of high-Z crystals to diffract energies up to 900 keV efficiently. And thirdly, we are exploring new concepts of Si-based lenses that could further improve the focusing capabilities, and thus the sensitivity of Laue lenses.

  20. THE CRAB PULSAR AT CENTIMETER WAVELENGTHS. II. SINGLE PULSES

    Energy Technology Data Exchange (ETDEWEB)

    Hankins, T. H.; Eilek, J. A. [Physics Department, New Mexico Tech, Socorro, NM 87801 (United States); Jones, G., E-mail: thankins@aoc.nrao.edu [Columbia University, New York, NY 10027 (United States)

    2016-12-10

    We have carried out new, high-frequency, high-time-resolution observations of the Crab pulsar. Combining these with our previous data, we characterize bright single pulses associated with the Main Pulse, both the Low-Frequency and High-Frequency Interpulses, and the two  High-Frequency Components. Our data include observations at frequencies ranging from 1 to 43 GHz with time resolutions down to a fraction of a nanosecond. We find that at least two types of emission physics are operating in this pulsar. Both Main Pulses and Low-Frequency Interpulses, up to ∼10 GHz, are characterized by nanoshot emission—overlapping clumps of narrowband nanoshots, each with its own polarization signature. High-Frequency Interpulses, between 5 and 30 GHz, are characterized by spectral band emission—linearly polarized emission containing ∼30 proportionately spaced spectral bands. We cannot say whether the longer-duration High-Frequency Components pulses are due to a scattering process, or if they come from yet another type of emission physics.

  1. Pump-probe spectroscopy of spin-injection dynamics in double quantum wells of diluted magnetic semiconductor

    International Nuclear Information System (INIS)

    Nishibayashi, K.; Aoshima, I.; Souma, I.; Murayama, A.; Oka, Y.

    2006-01-01

    Dynamics of spin injection has been investigated in a double quantum well (DQW) composed of a diluted magnetic semiconductor by the pump-probe transient absorption spectroscopy in magnetic field. The DQW consists of a non-magnetic well (NMW) of CdTe and a magnetic well (MW) of Cd 0.92 Mn 0.08 Te. The MW shows a transient absorption saturation in the exciton band for more than 200 ps after the optical pumping, while the exciton photoluminescence does not arise from the MW. In the NMW, the circular polarization degree of the transient absorption saturation shows an increase with increasing time. The results are interpreted by the individual tunneling of spin-polarized electrons and holes from the MW to the NMW with different tunneling times. Depolarization processes of the carrier spins in the MW and the NMW are also discussed

  2. Two-tint pump-probe measurements using a femtosecond laser oscillator and sharp-edged optical filters.

    Science.gov (United States)

    Kang, Kwangu; Koh, Yee Kan; Chiritescu, Catalin; Zheng, Xuan; Cahill, David G

    2008-11-01

    We describe a simple approach for rejecting unwanted scattered light in two types of time-resolved pump-probe measurements, time-domain thermoreflectance (TDTR) and time-resolved incoherent anti-Stokes Raman scattering (TRIARS). Sharp edged optical filters are used to create spectrally distinct pump and probe beams from the broad spectral output of a femtosecond Ti:sapphire laser oscillator. For TDTR, the diffusely scattered pump light is then blocked by a third optical filter. For TRIARS, depolarized scattering created by the pump is shifted in frequency by approximately 250 cm(-1) relative to the polarized scattering created by the probe; therefore, spectral features created by the pump and probe scattering can be easily distinguished.

  3. Broadband pump-probe spectroscopy with sub-10-fs resolution for probing ultrafast internal conversion and coherent phonons in carotenoids

    International Nuclear Information System (INIS)

    Polli, D.; Antognazza, M.R.; Brida, D.; Lanzani, G.; Cerullo, G.; De Silvestri, S.

    2008-01-01

    We use pump-probe spectroscopy with broadband detection to study electronic energy relaxation and coherent vibrational dynamics in carotenoids. A fast optical multichannel analyzer combined with a non-collinear optical parametric amplifier allows simultaneous acquisition of the differential transmission dynamics on the 500-700 nm wavelength range with sub-10-fs temporal resolution. The broad spectral coverage enables on the one hand a detailed study of the ultrafast bright-to-dark state internal conversion process; on the other hand, the tracking of the motion of the vibrational wavepacket launched on the ground state multidimensional potential energy surface. We present results on all-trans β-carotene and on a long-chain polyene in solution. The developed experimental setup enables the straightforward acquisition and analysis of coherent vibrational dynamics, highlighting time-frequency domain features with extreme resolution

  4. Gauge invariance in the theoretical description of time-resolved angle-resolved pump/probe photoemission spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Freericks, J. K.; Krishnamurthy, H. R.; Sentef, M. A.; Devereaux, T. P.

    2015-10-01

    Nonequilibrium calculations in the presence of an electric field are usually performed in a gauge, and need to be transformed to reveal the gauge-invariant observables. In this work, we discuss the issue of gauge invariance in the context of time-resolved angle-resolved pump/probe photoemission. If the probe is applied while the pump is still on, one must ensure that the calculations of the observed photocurrent are gauge invariant. We also discuss the requirement of the photoemission signal to be positive and the relationship of this constraint to gauge invariance. We end by discussing some technical details related to the perturbative derivation of the photoemission spectra, which involve processes where the pump pulse photoexcites electrons due to nonequilibrium effects.

  5. Ultrafast pump-probe reflectance spectroscopy: Why sodium makes Cu(In,Ga)Se2 solar cells better

    KAUST Repository

    Eid, Jessica; Usman, Anwar; Gereige, Issam; Duren, Jeroen Van; Lyssenko, Vadim; Leo, Karl; Mohammed, Omar F.

    2015-01-01

    Although Cu(In,Ga)Se2 (CIGS) solar cells have the highest efficiency of any thin-film solar cell, especially when sodium is incorporated, the fundamental device properties of ultrafast carrier transport and recombination in such cells remain not fully understood. Here, we explore the dynamics of charge carriers in CIGS absorber layers with varying concentrations of Na by femtosecond (fs) broadband pump-probe reflectance spectroscopy with 120 fs time resolution. By analyzing the time-resolved transient spectra in a different time domain, we show that a small amount of Na integrated by NaF deposition on top of sputtered Cu(In,Ga) prior to selenization forms CIGS, which induces slower recombination of the excited carriers. Here, we provide direct evidence for the elongation of carrier lifetimes by incorporating Na into CIGS.

  6. Ultrafast pump-probe reflectance spectroscopy: Why sodium makes Cu(In,Ga)Se2 solar cells better

    KAUST Repository

    Eid, Jessica

    2015-04-14

    Although Cu(In,Ga)Se2 (CIGS) solar cells have the highest efficiency of any thin-film solar cell, especially when sodium is incorporated, the fundamental device properties of ultrafast carrier transport and recombination in such cells remain not fully understood. Here, we explore the dynamics of charge carriers in CIGS absorber layers with varying concentrations of Na by femtosecond (fs) broadband pump-probe reflectance spectroscopy with 120 fs time resolution. By analyzing the time-resolved transient spectra in a different time domain, we show that a small amount of Na integrated by NaF deposition on top of sputtered Cu(In,Ga) prior to selenization forms CIGS, which induces slower recombination of the excited carriers. Here, we provide direct evidence for the elongation of carrier lifetimes by incorporating Na into CIGS.

  7. Light Driven Energy Research at LCLS: Planned Pump-Probe X-ray Spectroscopy Studies on Photosynthetic Water Splitting

    Science.gov (United States)

    Bergmann, Uwe

    2010-02-01

    Arguably the most important chemical reaction on earth is the photosynthetic splitting of water to molecular oxygen by the Mn-containing oxygen-evolving complex (Mn-OEC) in the protein known as photosystem II (PSII). It is this reaction which has, over the course of some 3.8 billion years, gradually filled our atmosphere with O2 and consequently enabled and sustained the evolution of complex aerobic life. Coupled to the reduction of carbon dioxide, biological photosynthesis contributes foodstuffs for nutrition while recycling CO2 from the atmosphere and replacing it with O2. By utilizing sunlight to power these energy-requiring reactions, photosynthesis also serves as a model for addressing societal energy needs as we enter an era of diminishing fossil hydrocarbon resources. Understanding, at the molecular level, the dynamics and mechanism of how nature has solved this problem is of fundamental importance and could be critical to aid in the design of manufactured devices to accomplish the conversion of sunlight into useful electrochemical energy and transportable fuel in the foreseeable future. In order to understand the photosynthetic splitting of water by the Mn-OEC we need to be able to follow the reaction in real time at an atomic level. A powerful probe to study the electronic and molecular structure of the Mn-OEC is x-ray spectroscopy. Here, in particular x-ray emission spectroscopy (XES) has two crucial qualities for LCLS based time-dependent pump-probe studies of the Mn-OEC: a) it directly probes the Mn oxidation state and ligation, b) it can be performed with wavelength dispersive optics to avoid the necessity of scanning in pump probe experiments. Recent results and the planned time dependent experiments at LCLS will be discussed. )

  8. Optical afterburner for an x-ray free electron laser as a tool for pump-probe experiments

    Directory of Open Access Journals (Sweden)

    E. L. Saldin

    2010-03-01

    Full Text Available We propose a new scheme for two-color operation of an x-ray self-amplified spontaneous emission free electron laser (SASE FEL. The scheme is based on an intrinsic feature of such a device: chaotic modulations of electron beam energy and energy spread on the scale of FEL coherence length are converted into large density modulations on the same scale with the help of a dispersion section, installed behind the x-ray undulator. Powerful radiation is then generated with the help of a dedicated radiator (like an undulator that selects a narrow spectral line, or one can simply use, for instance, broadband edge radiation. A typical radiation wavelength can be as short as a FEL coherence length, and can be redshifted by increasing the dispersion section strength. In practice it means the wavelength ranges from vacuum ultraviolet to infrared. The long-wavelength radiation pulse is naturally synchronized with the x-ray pulse and can be either directly used in pump-probe experiments or cross correlated with a high-power pulse from a conventional laser system. In this way experimenters overcome jitter problems and can perform pump-probe experiments with femtosecond resolution. Additional possibilities like on-line monitoring of x-ray pulse duration (making “optical replica” of an x-ray pulse are also discussed in the paper. The proposed scheme is very simple, cheap, and robust, and therefore can be easily realized in facilities like FLASH, European XFEL, LCLS, and SCSS.

  9. Dynamical neutron diffraction by curved crystals in the Laue geometry

    International Nuclear Information System (INIS)

    Albertini, G.; Melone, S.; Lagomarsino, S.; Mazkedian, S.; Puliti, P.; Rustichelli, F.

    1977-01-01

    The Taupin dynamical theory of X-ray diffraction by deformed crystals which was previously extended to the neutron diffraction by curved crystals in the Bragg geometry, is applied to calculate neutron diffraction patterns in the Laue geometry. The theoretical results are compared with experimental data on curved silicon crystals. The agreement is quite satisfactory. In the second part a simple model recently presented to describe neutron diffraction properties in the Bragg case is extended to the Laue case. The predictions of such a model are in satisfactory agreement with the rigorous theory and the experimental results. (author)

  10. Femtosecond visible/visible and visible/mid-IR pump-probe study of the photosystem II core antenna complex CP47

    NARCIS (Netherlands)

    Groot, M.L.; Breton, J.; van Wilderen, L.; Dekker, J.P.; van Grondelle, R.

    2004-01-01

    CP47 is one of the two core antenna proteins of Photosystem II involved in the transfer of solar energy toward the photochemically active reaction center, the D1D2cytb559 complex. We have performed vis/vis and vis/mid-IR pump-probe experiments at room temperature as a first step in linking the

  11. Flame Motion In Gas Turbine Burner From Averages Of Single-Pulse Flame Fronts

    Energy Technology Data Exchange (ETDEWEB)

    Tylli, N.; Hubschmid, W.; Inauen, A.; Bombach, R.; Schenker, S.; Guethe, F. [Alstom (Switzerland); Haffner, K. [Alstom (Switzerland)

    2005-03-01

    Thermo acoustic instabilities of a gas turbine burner were investigated by flame front localization from measured OH laser-induced fluorescence single pulse signals. The average position of the flame was obtained from the superposition of the single pulse flame fronts at constant phase of the dominant acoustic oscillation. One observes that the flame position varies periodically with the phase angle of the dominant acoustic oscillation. (author)

  12. Enhancement of beam pulse controllability for a single-pulse formation system of a cyclotron

    International Nuclear Information System (INIS)

    Kurashima, Satoshi; Miyawaki, Nobumasa; Kashiwagi, Hirotsugu; Okumura, Susumu; Taguchi, Mitsumasa; Fukuda, Mitsuhiro

    2015-01-01

    The single-pulse formation technique using a beam chopping system consisting of two types of high-voltage beam kickers was improved to enhance the quality and intensity of the single-pulse beam with a pulse interval over 1 μs at the Japan Atomic Energy Agency cyclotron facility. A contamination rate of neighboring beam bunches in the single-pulse beam was reduced to less than 0.1%. Long-term purification of the single pulse beam was guaranteed by the well-controlled magnetic field stabilization system for the cyclotron magnet. Reduction of the multi-turn extraction number for suppressing the neighboring beam bunch contamination was achieved by restriction of a beam phase width and precise optimization of a particle acceleration phase. In addition, the single-pulse beam intensity was increased by a factor of two or more by a combination of two types of beam bunchers using sinusoidal and saw-tooth voltage waveforms. Provision of the high quality intense single-pulse beam contributed to improve the accuracy of experiments for investigation of scintillation light time-profile and for neutron energy measurement by a time-of-flight method

  13. Ultrafast Photodissociation Dynamics of the F State of Sulfur Dioxide by Femtosecond Time-Resolved Pump-Probe Method

    International Nuclear Information System (INIS)

    Zhang Dong-Dong; Ni Qiang; Luo Si-Zuo; Zhang Jing; Liu Hang; Xu Hai-Feng; Jin Ming-Xing; Ding Da-Jun

    2011-01-01

    A femtosecond pump-probe method is employed to study the dissociation dynamics of sulfur dioxide. SO 2 molecules are excited to the F state by absorbing two photons of 267 nm femtosecond laser pulses, and ionized by 400 nm laser pulses at different delay times between the two lasers. Transients of both parent ions (SO + 2 ) and the fragment ions (SO + , S + and O + ) are observed. The SO + 2 transient can be well fitted to a biexponential decay comprising a fast and a slow component of 280 fs and 2.97 ps lifetimes, respectively. The SO + transient consists of two growth components of 270 fs and 2.50 ps. The results clearly show that the F state of SO 2 dissociates along an S-O bond. The transients of S + and O + , however, have different behavior, which consist of a fast growth and a long decay component. A possible mechanism of the fragment formation is discussed to understand the dissociation dynamics of the F state of SO 2 . (atomic and molecular physics)

  14. Optical beam transport to a remote location for low jitter pump-probe experiments with a free electron laser

    Directory of Open Access Journals (Sweden)

    P. Cinquegrana

    2014-04-01

    Full Text Available In this paper we propose a scheme that allows a strong reduction of the timing jitter between the pulses of a free electron laser (FEL and external laser pulses delivered simultaneously at the FEL experimental stations for pump-probe–type experiments. The technique, applicable to all seeding-based FEL schemes, relies on the free-space optical transport of a portion of the seed laser pulse from its optical table to the experimental stations. The results presented here demonstrate that a carefully designed laser beam transport, incorporating also a transverse beam position stabilization, allows one to keep the timing fluctuations, added by as much as 150 m of free space propagation and a number of beam folding mirrors, to less than 4 femtoseconds rms. By its nature our scheme removes the major common timing jitter sources, so the overall jitter in pump-probe measurements done in this way will be below 10 fs (with a margin to be lowered to below 5 fs, much better than the best results reported previously in the literature amounting to 33 fs rms.

  15. Intraminiband Relaxation In Doped GaAs/AlGaAs Superlattices Studied By Two-Color Infrared Pump-Probe Experiments

    International Nuclear Information System (INIS)

    Wagner, M.; Stehr, D.; Schneider, H.; Helm, M.; Andrews, A. M.; Roch, T.; Strasser, G.

    2010-01-01

    In this work we report on two-color pump-probe measurements to investigate the intraminiband dynamics of doped GaAs/AlGaAs superlattices with different miniband widths smaller or larger than the optical phonon energy. For a miniband with a width larger than the optical phonon energy we found a fast relaxation, independent of the excitation intensity. For narrow minibands this relaxation takes longer and shows a strong temperature and intensity dependence.

  16. CBED contrast in the lower order Laue zone

    International Nuclear Information System (INIS)

    Rossouw, C.J.; Maunders, C.J.; Whitfield, H.J.; Etheridge, J.

    2006-01-01

    Contrast in a systematic arrangement of lower order Laue zone (LOLZ) beams is reported and analysed using a Bloch wave description. Observations are reported for hexagonal barium ruthenium zirconate (Ba 4 Ru 3 ZrO 12 ) and barium ruthenium titanate (Ba 3 Ti 2 RuO 9 ), both near the c -axis orientation. The specific scattering dynamics invoked by this diffraction geometry may have novel uses in the exploration of crystallographic parameters

  17. Time of flight Laue fiber diffraction studies of perdeuterated DNA

    Energy Technology Data Exchange (ETDEWEB)

    Forsyth, V.T.; Whalley, M.A.; Mahendrasingam, A.; Fuller, W. [Keele Univ. (United Kingdom)] [and others

    1994-12-31

    The diffractometer SXD at the Rutherford Appleton Laboratory ISIS pulsed neutron source has been used to record high resolution time-of-flight Laue fiber diffraction data from DNA. These experiments, which are the first of their kind, were undertaken using fibers of DNA in the A conformation and prepared using deuterated DNA in order to minimis incoherent background scattering. These studies complement previous experiments on instrument D19 at the Institute Laue Langevin using monochromatic neutrons. Sample preparation involved drawing large numbers of these deuterated DNA fibers and mounting them in a parallel array. The strategy of data collection is discussed in terms of camera design, sample environment and data collection. The methods used to correct the recorded time-of-flight data and map it into the final reciprocal space fiber diffraction dataset are also discussed. Difference Fourier maps showing the distribution of water around A-DNA calculated on the basis of these data are compared with results obtained using data recorded from hydrogenated A-DNA on D19. Since the methods used for sample preparation, data collection and data processing are fundamentally different for the monochromatic and Laue techniques, the results of these experiments also afford a valuable opportunity to independently test the data reduction and analysis techniques used in the two methods.

  18. Time-resolved Laue diffraction from protein crystals: Instrumental considerations

    International Nuclear Information System (INIS)

    Bilderback, D.H.; Cornell Univ., Ithaca, NY; Moffat, K.; Szebenyi, D.M.E.

    1984-01-01

    A serious limitation of macromolecular crystallography has been its inability to determine changes in structure on a biochemical time scale of milliseconds or less. Recently, we have shown that X-ray exposures on single crystals of macromolecules may be obtained in the millisecond time range through the use of intense, polychromatic radiation with Δlambda/lambda approx.= 0.2 derived from the Cornell High Energy Synchrotron Source, CHESS. Such radiation falling on a stationary crystal yields a Laue diffraction pattern, in which almost all Laue reflections arise from a unique set of Miller indices and where their intensities are automatically integrated over wavelength. This Laue technique requires wide band pass optics, which may be obtained by a combination of reflection and transmission mirrors, filters or layered synthetic microstructures. Time-resolved macromolecular crystallography may be achieved by several data collection schemes: 'one-shot' recording coupled to a simple streak camera, repetitive sample perturbation coupled to a detector with temporal resolution and repetitive perturbation which uses the synchrotron pulses for stroboscopic triggering and detection. These schemes are appropriate for different time scales, roughly the milli-, micro- and nanosecond regimes. It appears that time-resolved crystallography is entirely feasible, with an ultimate time resolution limited only by the length of a synchrotron light pulse, some 150 ps at CHESS. (orig.)

  19. Mammography imaging studies using a laue crystal analyzer

    International Nuclear Information System (INIS)

    Chapman, D.; Thomlinson, W.; Arfelli, F.

    1995-01-01

    Synchrotron based mammography imaging experiments have been performed with monochromatic x-rays in which a laue crystal placed after the object being imaged has been used to split the beam transmitted through the object. The X27C R ampersand D beamline at the National Synchrotron Light Source was used with the white beam monochromatized by a double crystal Si(111) monochromator tuned to 18 keV. The imaging beam was a thin horizontal line approximately 0.5 mm high by 100 mm wide. Images were acquired in line scan mode with the phantom and detector both scanned together. The detector for these experiments was an image plate. A thin Si(l11) laue analyzer was used to diffract a portion of the beam transmitted through the phantom before the image plate detector. This ''scatter free'' diffracted beam was then recorded on the image plate during the phantom scan. Since the thin laue crystal also transmitted a fraction of the incident beam, this beam was also simultaneously recorded on the image plate. The imaging results are interpreted in terms of an x-ray schliere or refractive index inhomogeneities. The analyzer images taken at various points in the rocking curve will be presented

  20. Beam-smiling in bent-Laue monochromators

    International Nuclear Information System (INIS)

    Ren, B.; Dilmanian, F. A.; Wu, X. Y.; Huang, X.; Chapman, L. D.; Ivanov, I.; Zhong, Z.; Thomlinson, W. C.

    1997-01-01

    When a wide fan-shaped x-ray beam is diffracted by a bent crystal in the Laue geometry, the profile of the diffracted beam generally does not appear as a straight line, but as a line with its ends curved up or curved down. This effect, referred to as 'beam-smiling', has been a major obstacle in developing bent-Laue crystal monochromators for medical applications of synchrotron x-ray. We modeled a cylindrically bent crystal using the Finite Element Analysis (FEA) method, and we carried out experiments at the National Synchrotron Light Source and Cornell High Energy Synchrotron Source. Our studies show that, while beam-smiling exists in most of the crystal's area because of anticlastic bending effects, there is a region parallel to the bending axis of the crystal where the diffracted beam is 'smile-free'. By applying asymmetrical bending, this smile-free region can be shifted vertically away from the geometric center of the crystal, as desired. This leads to a novel method of compensating for beam-smiling. We will discuss the method of ''differential bending'' for smile removal, beam-smiling in the Cauchios and the polychromatic geometry, and the implications of the method on developing single- and double-bent Laue monochromators. The experimental results will be discussed, concentrating on specific beam-smiling observation and removal as applied to the new monochromator of the Multiple Energy Computed Tomography [MECT] project of the Medical Department, Brookhaven National Laboratory

  1. A split-beam probe-pump-probe scheme for femtosecond time resolved protein X-ray crystallography

    Directory of Open Access Journals (Sweden)

    Jasper J. van Thor

    2015-01-01

    Full Text Available In order to exploit the femtosecond pulse duration of X-ray Free-Electron Lasers (XFEL operating in the hard X-ray regime for ultrafast time-resolved protein crystallography experiments, critical parameters that determine the crystallographic signal-to-noise (I/σI must be addressed. For single-crystal studies under low absorbed dose conditions, it has been shown that the intrinsic pulse intensity stability as well as mode structure and jitter of this structure, significantly affect the crystallographic signal-to-noise. Here, geometrical parameters are theoretically explored for a three-beam scheme: X-ray probe, optical pump, X-ray probe (or “probe-pump-probe” which will allow experimental determination of the photo-induced structure factor amplitude differences, ΔF, in a ratiometric manner, thereby internally referencing the intensity noise of the XFEL source. In addition to a non-collinear split-beam geometry which separates un-pumped and pumped diffraction patterns on an area detector, applying an additional convergence angle to both beams by focusing leads to integration over mosaic blocks in the case of well-ordered stationary protein crystals. Ray-tracing X-ray diffraction simulations are performed for an example using photoactive yellow protein crystals in order to explore the geometrical design parameters which would be needed. The specifications for an X-ray split and delay instrument that implements both an offset angle and focused beams are discussed, for implementation of a probe-pump-probe scheme at the European XFEL. We discuss possible extension of single crystal studies to serial femtosecond crystallography, particularly in view of the expected X-ray damage and ablation due to the first probe pulse.

  2. Development of a Laue lens for nuclear astrophysics

    International Nuclear Information System (INIS)

    Barriere, N.

    2008-04-01

    The Laue lenses we study focuses in the domain of 0.1-1 MeV thanks to Bragg diffraction in the volume of a large number of small crystal tiles. The focal length of a typical Laue lens system is of the order of 100 m. This requirement calls for two formation flying satellites maintaining lens and detector at the focal distance. The major breakthrough of Laue lenses is to decouple collecting area from detector area. Concentrating a signal from the large area of a Laue lens onto a small focal spot dramatically increases the signal over background ratio with respect to present technologies. Here is the reason for the long awaited leap in sensitivity. The objective of the present thesis was to improve the concept, finding viable technical solutions towards a future space mission. Two aspects of the lens development have been highlighted in this thesis: the first one is an analytical model of the lens that is used to calculate and improve the performance of a certain configuration, the second aspect concerns the search and the characterization of diffracting media of interest. The lens model developed relies on a fast semi-analytical simulation library, permitting to build several design- and optimisation-tools. For the configuration of a given lens, this code computes the resulting effective area and point spread function in a handful of seconds. The model helps finding lens configurations (mass, pack ratio of the lens rings,...) which are automatically refined to match with effective area and energy coverage constraints. These tools have been used to investigate various design aspects, such as the influence of focal length, size, mosaic spread, structure and materials of crystals, etc... The central evaluation criterion in the model is a figure of merit, based on the compactness of the focal spot and the intensity of the collected signal. The second part of this work addresses the actual search and characterization of crystals potentially interesting for Laue lenses

  3. Catastrophic optical mirror damage in diode lasers monitored during single-pulse operation

    DEFF Research Database (Denmark)

    Zegler, M.; Tomm, J.W.; Reeber, D.

    2009-01-01

    is achieved. The thermal runaway process is unambiguously related to the occurrence of a “thermal flash.” A one-by-one correlation between nearfield, thermal flash, thermal runaway, and structural damage is observed. The single-pulse excitation technique allows for controlling the propagation...

  4. The ground support equipment for the LAUE project

    Science.gov (United States)

    Caroli, E.; Auricchio, N.; Basili, A.; Carassiti, V.; Cassese, F.; Del Sordo, S.; Frontera, F.; Pecora, M.; Recanatesi, L.; Schiavone, F.; Silvestri, S.; Squerzanti, S.; Stephen, J. B.; Virgilli, E.

    2013-09-01

    The development of wide band Laue lens imaging technology is challenging, but has important potential applications in hard X- and γ-ray space instrumentation for the coming decades. The Italian Space Agency has funded a project dedicated to the development of a reliable technology to assemble a wide band Laue lens for use in space. The ground support equipment (GSE) for this project was fundamental to its eventual success... The GSE was implemented in a hard X-ray beam line built at the University of Ferrara and had the main purpose of controlling the assembly of crystals onto the Laue lens petal and to verify its final performance. The GSE incorporates the management and control of all the movements of the beam line mechanical subsystems and of the precision positioner (based on a Hexapod tool) of crystals on the petal, as well as the acquisition, storing and analysis of data obtained from the focal plane detectors (an HPGe spectrometer and an X-ray flat panel imager). The GSE is based on two PC's connected through a local network: one, placed inside the beam line, to which all the movement subsystems and the detector I/O interface and on which all the management and acquisition S/W runs, the other in the control room allows the remote control and implements the offline analysis S/W of the data obtained from the detectors. Herein we report on the GSE structure with its interface with the beam line mechanical system, with the fine crystal positioner and with the focal plane detector. Furthermore we describe the SW developed for the handling of the mechanical movement subsystems and for the analysis of the detector data with the procedure adopted for the correct orientation of the crystals before their bonding on the lens petal support.

  5. Beam-smiling in bent-Laue monochromators

    International Nuclear Information System (INIS)

    Ren, B.; Dilmanian, F.A.; Wu, X.Y.; Huang, X.; Ivanov, I.; Thomlinson, W.C.

    1997-01-01

    When a wide fan-shaped x-ray beam is diffracted by a bent crystal in the Laue geometry, the profile of the diffracted beam generally does not appear as a straight line, but as a line with its ends curved up or curved down. This effect, referred to as ' beam-smiling', has been a major obstacle in developing bent-Laue crystal monochromators for medical applications of synchrotron x-ray. We modeled a cylindrically bent crystal using the Finite Element Analysis (FEA) method, and we carried out experiments at the National Synchrotron Light Source and Cornell High Energy Synchrotron Source. Our studies show that, while beam-smiling exists in most of the crystal close-quote s area because of anticlastic bending effects, there is a region parallel to the bending axis of the crystal where the diffracted beam is ' smile-free'. By applying asymmetrical bending, this smile-free region can be shifted vertically away from the geometric center of the crystal, as desired. This leads to a novel method of compensating for beam-smiling. We will discuss the method of ' differential bending' for smile removal, beam-smiling in the Cauchios and the polychromatic geometry, and the implications of the method on developing single- and double-bent Laue monochromators. The experimental results will be discussed, concentrating on specific beam-smiling observation and removal as applied to the new monochromator of the Multiple Energy Computed Tomography [MECT] project of the Medical Department, Brookhaven National Laboratory. copyright 1997 American Institute of Physics

  6. Sectioning of multilayers to make a multilayer Laue lens

    International Nuclear Information System (INIS)

    Kang, Hyon Chol; Stephenson, G. Brian; Liu Chian; Conley, Ray; Khachatryan, Ruben; Wieczorek, Michael; Macrander, Albert T.; Yan Hanfei; Maser, Joerg; Hiller, Jon; Koritala, Rachel

    2007-01-01

    We report a process to fabricate multilayer Laue lenses (MLL's) by sectioning and thinning multilayer films. This method can produce a linear zone plate structure with a very large ratio of zone depth to width (e.g., >1000), orders of magnitude larger than can be attained with photolithography. Consequently, MLL's are advantageous for efficient nanofocusing of hard x rays. MLL structures prepared by the technique reported here have been tested at an x-ray energy of 19.5 keV, and a diffraction-limited performance was observed. The present article reports the fabrication techniques that were used to make the MLL's

  7. Ultrafast S1 and ICT state dynamics of a marine carotenoid probed by femtosecond one- and two-photon pump-probe spectroscopy

    International Nuclear Information System (INIS)

    Kosumi, Daisuke; Kusumoto, Toshiyuki; Fujii, Ritsuko; Sugisaki, Mitsuru; Iinuma, Yoshiro; Oka, Naohiro; Takaesu, Yuki; Taira, Tomonori; Iha, Masahiko; Frank, Harry A.; Hashimoto, Hideki

    2011-01-01

    Ultrafast relaxation kinetics of fucoxanthin in polar and non-polar solvents have been studied by femtosecond pump-probe spectroscopy. Transient absorption associated with S 1 or intramolecular charge transfer (ICT) excited state has been observed following either one-photon excitation to the optically allowed S 2 state or two-photon excitation to the symmetry-forbidden S 1 state. The results suggest that the ICT state formed after excitation of fucoxanthin in a polar solvent is a distinct excited state from S 1 .

  8. Ultrafast S{sub 1} and ICT state dynamics of a marine carotenoid probed by femtosecond one- and two-photon pump-probe spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Kosumi, Daisuke, E-mail: kosumi@sci.osaka-cu.ac.j [CREST/JST and Department of Physics, Graduate School of Science, Osaka City University, 3-3-138 Sugimoto, Sumiyoshi-ku, Osaka 558-8585 (Japan); Kusumoto, Toshiyuki [CREST/JST and Department of Physics, Graduate School of Science, Osaka City University, 3-3-138 Sugimoto, Sumiyoshi-ku, Osaka 558-8585 (Japan); Fujii, Ritsuko; Sugisaki, Mitsuru [CREST/JST and Department of Physics, Graduate School of Science, Osaka City University, 3-3-138 Sugimoto, Sumiyoshi-ku, Osaka 558-8585 (Japan); Osaka City University Advanced Research Institute for Natural Science and Technology (OCARINA), Osaka (Japan); Iinuma, Yoshiro; Oka, Naohiro; Takaesu, Yuki; Taira, Tomonori; Iha, Masahiko [South Product Co. Ltd., 12-75 Suzaki, Uruma-shi, Okinawa 904-2234 (Japan); Frank, Harry A. [Department of Chemistry, University of Connecticut, Storrs, CT 06269-3060 (United States); Hashimoto, Hideki, E-mail: hassy@sci.osaka-cu.ac.j [CREST/JST and Department of Physics, Graduate School of Science, Osaka City University, 3-3-138 Sugimoto, Sumiyoshi-ku, Osaka 558-8585 (Japan); Osaka City University Advanced Research Institute for Natural Science and Technology (OCARINA), Osaka (Japan)

    2011-03-15

    Ultrafast relaxation kinetics of fucoxanthin in polar and non-polar solvents have been studied by femtosecond pump-probe spectroscopy. Transient absorption associated with S{sub 1} or intramolecular charge transfer (ICT) excited state has been observed following either one-photon excitation to the optically allowed S{sub 2} state or two-photon excitation to the symmetry-forbidden S{sub 1} state. The results suggest that the ICT state formed after excitation of fucoxanthin in a polar solvent is a distinct excited state from S{sub 1}.

  9. Phase contrast image segmentation using a Laue analyser crystal

    International Nuclear Information System (INIS)

    Kitchen, Marcus J; Paganin, David M; Lewis, Robert A; Pavlov, Konstantin M; Uesugi, Kentaro; Allison, Beth J; Hooper, Stuart B

    2011-01-01

    Dual-energy x-ray imaging is a powerful tool enabling two-component samples to be separated into their constituent objects from two-dimensional images. Phase contrast x-ray imaging can render the boundaries between media of differing refractive indices visible, despite them having similar attenuation properties; this is important for imaging biological soft tissues. We have used a Laue analyser crystal and a monochromatic x-ray source to combine the benefits of both techniques. The Laue analyser creates two distinct phase contrast images that can be simultaneously acquired on a high-resolution detector. These images can be combined to separate the effects of x-ray phase, absorption and scattering and, using the known complex refractive indices of the sample, to quantitatively segment its component materials. We have successfully validated this phase contrast image segmentation (PCIS) using a two-component phantom, containing an iodinated contrast agent, and have also separated the lungs and ribcage in images of a mouse thorax. Simultaneous image acquisition has enabled us to perform functional segmentation of the mouse thorax throughout the respiratory cycle during mechanical ventilation.

  10. Dielectric breakdown and healing of anodic oxide films on aluminium under single pulse anodizing

    International Nuclear Information System (INIS)

    Sah, Santosh Prasad; Tatsuno, Yasuhiro; Aoki, Yoshitaka; Habazaki, Hiroki

    2011-01-01

    Research highlights: → We examined dielectric breakdown of anodic alumina by single pulse anodizing. → Current transients and morphology of discharge channels are dependent upon electrolyte and voltage. → There is a good correlation between current transient and morphology of discharge channel. → Healing of open discharge pores occurs in alkaline silicate, but not in pentaborate electrolyte. - Abstract: Single pulse anodizing of aluminium micro-electrode has been employed to study the behaviour of dielectric breakdown and subsequent oxide formation on aluminium in alkaline silicate and pentaborate electrolytes. Current transients during applying pulse voltage have been measured, and surface has been observed by scanning electron microscopy. Two types of current transients are observed, depending on the electrolyte and applied voltage. There is a good correlation between the current transient behaviour and the shape of discharge channels. In alkaline silicate electrolyte, circular open pores are healed by increasing the pulse width, but such healing is not obvious in pentaborate electrolyte.

  11. Development of a Pump-Probe System using a Non-Coated ZnSe Beam Splitter Cube for an MIR-FEL

    CERN Document Server

    Heya, Manabu; Horiike, Hiroshi; Ishii, Katsonuri; Suzuki, Sachiko

    2004-01-01

    A pump-probe technique is essential for a proper understanding of laser interaction with tissue and material. Our pump-probe system divides the incident mid-infrared Free Electron Laser (MIR-FEL) into two beams with equal intensity, and crosses simultaneously the two incoming beams at the same position. One is for a pump beam, another is for a probe beam. Time-resolved absorption spectroscopy involving this technique gives us information on the vibrational dynamics of molecules. We have developed this system for an MIR-FEL using a non-coating ZnSe beam splitter cube. The beam splitter cube is composed of two ZnSe prisms in the shape like a trapezoid. The two pulses with equal intensity are generated due to Fresnel reflection and transmission at the boundary between two prisms, then are reflected due to total reflection at other side boundaries between each prism and air, and illuminate simultaneously the same spot. We have conducted a proof-of-concept of experiment of this system using an MIR-FEL. We showed t...

  12. High-repetition-rate setup for pump-probe time-resolved XUV-IR experiments employing ion and electron momentum imaging

    Science.gov (United States)

    Pathak, Shashank; Robatjazi, Seyyed Javad; Wright Lee, Pearson; Raju Pandiri, Kanaka; Rolles, Daniel; Rudenko, Artem

    2017-04-01

    J.R. Macdonald Laboratory, Department of Physics, Kansas State University, Manhattan KS, USA We report on the development of a versatile experimental setup for XUV-IR pump-probe experiments using a 10 kHz high-harmonic generation (HHG) source and two different charged-particle momentum imaging spectrometers. The HHG source, based on a commercial KM Labs eXtreme Ultraviolet Ultrafast Source, is capable of delivering XUV radiation of less than 30 fs pulse duration in the photon energy range of 17 eV to 100 eV. It can be coupled either to a conventional velocity map imaging (VMI) setup with an atomic, molecular, or nanoparticle target; or to a novel double-sided VMI spectrometer equipped with two delay-line detectors for coincidence studies. An overview of the setup and results of first pump-probe experiments including studies of two-color double ionization of Xe and time-resolved dynamics of photoionized CO2 molecule will be presented. This project is supported in part by National Science Foundation (NSF-EPSCOR) Award No. IIA-1430493 and in part by the Chemical science, Geosciences, and Bio-Science division, Office of Basic Energy Science, Office of science, U.S. Department of Energy. K.

  13. Development of a Laue lens for nuclear astrophysics

    International Nuclear Information System (INIS)

    Rousselle, Julien

    2011-01-01

    In this work, a new type of gamma-ray telescope is presented. It features a crystal diffraction lens that concentrates photons from a large photon collecting area onto a small detector. In such a Laue lens, a large number of crystals are disposed on concentric rings; each crystal can be considered as a little mirror which deviates gamma-rays through Bragg diffraction from the incident beam onto a common focal spot. The principle of the Laue lens for astrophysics was demonstrated with the balloon mission CLAIRE. The objective of this work was to develop the Laue Lens concept into a sensitive, space qualified optics for a future satellite mission. This contribution consisted of two main facets: a) finding appropriate crystal materials and improving the performance of the diffracting crystals, and b) develop a prototype segment for a space qualified lens. Exploring new diffracting media and improving the performance of individual crystals implied the development of numerical simulations of the diffraction process for various types of mosaic and CDP (Curved Diffraction Plane) crystals. These simulations were used to select suitable crystals to be grown and to be tested. Two different X-ray facilities were used to probe the crystalline quality of candidate materials: the European Synchrotron Radiation Facility (ESRF, France) and the high neutron flux reactor at ILL (France). During 10 beam-runs (and a total of 3 months of measurement), a large number of samples were tested, including Ag, Ir, Pt, Au, Pb, Rh, AsGa, SiGe, and Cu crystals. Outstanding performances were established for gold and silver crystals (>500 keV), Cu and Ge (300-500 keV) crystals and SiGe CDP (<300 keV) crystal. The second facet of this work consisted of designing, manufacturing and characterizing a prototype lens segment. This R and D program was completed in collaboration with the CNES and Thales Alenia Space. For a representative sample of metal and semiconductor crystals that were mounted on the

  14. The NSLS-II Multilayer Laue Lens Deposition System

    International Nuclear Information System (INIS)

    Conley, R.; Bouet, N.; Biancarosa, J.; Shen, Q.; Boas, L.; Feraca, J.; Rosenbaum, L.

    2009-01-01

    The NSLS-II(1) program has a requirement for an unprecedented level of x-ray nanofocusing and has selected the wedged multilayer Laue lens(2,3) (MLL) as the optic of choice to meet this goal. In order to fabricate the MLL a deposition system is required that is capable of depositing depth-graded and laterally-graded multilayers with precise thickness control over many thousands of layers, with total film growth in one run up to 100 m thick or greater. This machine design expounds on the positive features of a rotary deposition system(4) constructed previously for MLLs and will contain multiple stationary, horizontally-oriented magnetron sources where a transport will move a substrate back and forth in a linear fashion over shaped apertures at well-defined velocities to affect a multilayer coating.

  15. Bonded Multilayer Laue Lens for focusing hard X-rays

    International Nuclear Information System (INIS)

    Liu Chian; Conley, R.; Qian, J.; Kewish, C.M.; Macrander, A.T.; Maser, J.; Kang, H.C.; Yan, H.; Stephenson, G.B.

    2007-01-01

    We have fabricated partial Multilayer Laue Lens (MLL) linear zone plate structures with thousands of alternating WSi 2 and Si layers and various outermost zone widths according to the Fresnel zone plate formula. Using partial MLL structures, we were able to focus hard X-rays to line foci with a width of 30 nm and below. Here, we describe challenges and approaches used to bond these multilayers to achieve line and point focusing. Bonding was done by coating two multilayers with AuSn and heating in a vacuum oven at 280-300 o C. X-ray reflectivity measurements confirmed that there was no change in the multilayers after heating to 350 o C. A bonded MLL was polished to a 5-25 μm wedge without cracking. SEM image analyses found well-positioned multilayers after bonding. These results demonstrate the feasibility of a bonded full MLL for focusing hard X-rays

  16. Characterization of a multilayer Laue lens with imperfections

    International Nuclear Information System (INIS)

    Yan, H.; Kang, H.C.; Maser, J.; Macrander, A.T.; Kewish, C.M.; Liu, C.; Conley, R.; Stephenson, G.B.

    2007-01-01

    We present a simulation result of the focusing performance of a multilayer Laue lens (MLL) with imperfections. Imperfections we have studied correspond to deviations of sequence of layers in the fabricated structure from the zone plate law. The actual sequence of layers of the MLL is measured by scanning electron microscope (SEM), and fitted by second order polynomials. X-ray characterization of the MLL structures is performed using coherent X-rays at the Advanced Photon Source. We observe very good agreement between experiment and simulation. This demonstrates that our simulation method can serve as an efficient tool to characterize the focusing performance of MLLs with imperfections, and thereby allows us to provide feedback following deposition and fabrication of the MLL structures and optimization of focusing structures prior to X-ray characterization

  17. MAX: Development of a Laue diffraction lens for nuclear astrophysics

    International Nuclear Information System (INIS)

    Barriere, N.; Ballmoos, P. von; Skinner, G.; Smither, B.; Bastie, P.; Hinglais, E.; Abrosimov, N.; Alvarez, J.M.; Andersen, K.; Courtois, P.; Halloin, H.; Harris, M.; Isern, J.; Jean, P.; Knoedlseder, J.; Ubertini, P.; Vedrenne, G.; Weidenspointner, G.; Wunderer, C.

    2006-01-01

    The next generation of instrumentation for nuclear astrophysics will have to achieve an improvement in sensitivity by a factor of 10-100 over present technologies. With the focusing gamma-ray telescope MAX we take up this challenge and propose to combine the required sensitivity with high spectral and angular resolution, and the capability to measure the polarization of the photons. MAX is a space-borne crystal diffraction telescope, featuring a broad-band Laue lens optimized for the observation of compact sources in two wide energy bands of high astrophysical relevance. Gamma rays will be focused from the large collecting area of a crystal diffraction lens onto a very small detector volume. As a consequence, the signal to background ratio is greatly enhanced, leading to unprecedented sensitivities

  18. Intercomparison of the comparative reactivity method (CRM) and pump-probe technique for measuring total OH reactivity in an urban environment

    Science.gov (United States)

    Hansen, R. F.; Blocquet, M.; Schoemaecker, C.; Léonardis, T.; Locoge, N.; Fittschen, C.; Hanoune, B.; Stevens, P. S.; Sinha, V.; Dusanter, S.

    2015-10-01

    The investigation of hydroxyl radical (OH) chemistry during intensive field campaigns has led to the development of several techniques dedicated to ambient measurements of total OH reactivity, which is the inverse of the OH lifetime. Three techniques are currently used during field campaigns, including the total OH loss rate method, the pump-probe method, and the comparative reactivity method. However, no formal intercomparison of these techniques has been published so far, and there is a need to ensure that measurements of total OH reactivity are consistent among the different techniques. An intercomparison of two OH reactivity instruments, one based on the comparative reactivity method (CRM) and the other based on the pump-probe method, was performed in October 2012 in a NOx-rich environment, which is known to be challenging for the CRM technique. This study presents an extensive description of the two instruments, the CRM instrument from Mines Douai (MD-CRM) and the pump-probe instrument from the University of Lille (UL-FAGE), and highlights instrumental issues associated with the two techniques. It was found that the CRM instrument used in this study underestimates ambient OH reactivity by approximately 20 % due to the photolysis of volatile organic compounds (VOCs) inside the sampling reactor; this value is dependent on the position of the lamp within the reactor. However, this issue can easily be fixed, and the photolysis of VOCs was successfully reduced to a negligible level after this intercomparison campaign. The UL-FAGE instrument may also underestimate ambient OH reactivity due to the difficulty to accurately measure the instrumental zero. It was found that the measurements are likely biased by approximately 2 s-1, due to impurities in humid zero air. Two weeks of ambient sampling indicate that the measurements performed by the two OH reactivity instruments are in agreement, within the measurement uncertainties for each instrument, for NOx mixing ratios

  19. Temperature dependant thermal and mechanical properties of a metal-phase change layer interface using the time resolved pump probe technique

    International Nuclear Information System (INIS)

    Schick, V; Battaglia, J-L; Kusiak, A; Rossignol, C; Wiemer, C

    2011-01-01

    Time Resolved Pump Probe (TRPP) technique has been implemented to study the thermal and mechanical properties of Ge 2 Sb 2 Te 5 (GST) film deposited on a silicon substrate. According to the knowledge of the thermal properties of the GST layer, the temperature dependant Thermal Boundary Resistance (TBR) at the metal-GST interface is evaluated. Measuring the acoustic oscillation and more particularly its damping leads to characterize the adhesion at the metal - GST interface. This quantity can be efficiently related to the temperature dependent TBR in the 25 deg. C - 400 deg. C range. The TBR increases with temperature and follows the changes of the crystalline structure of materials. A linear relation between the acoustic reflection coefficient and the logarithm of the thermal boundary resistance is found.

  20. Polarization-dependent pump-probe studies in atomic fine-structure levels: towards the production of spin-polarized electrons

    International Nuclear Information System (INIS)

    Sokell, E.; Zamith, S.; Bouchene, M.A.; Girard, B.

    2000-01-01

    The precession of orbital and spin angular momentum vectors has been observed in a pump-probe study of the 4P fine-structure states of atomic potassium. A femtosecond pump pulse prepared a coherent superposition of the two fine-structure components. A time-delayed probe pulse then ionized the system after it had been allowed to evolve freely. Oscillations recorded in the ion signal reflect the evolution of the orientation of the orbital and spin angular momentum due to spin-orbit coupling. This interpretation gives physical insight into the cause of the half-period phase shift observed when the relative polarizations of the laser pulses were changed from parallel to perpendicular. Finally, it is shown that these changes in the orientation of the spin momentum vector of the system can be utilized to produce highly spin-polarized free electrons on the femtosecond scale. (author)

  1. Can a single pulse transcranial magnetic stimulation targeted to the motor cortex interrupt pain processing?

    Science.gov (United States)

    Kisler, Lee-Bareket; Gurion, Ilan; Granovsky, Yelena; Sinai, Alon; Sprecher, Elliot; Shamay-Tsoory, Simone; Weissman-Fogel, Irit

    2018-01-01

    The modulatory role of the primary motor cortex (M1), reflected by an inhibitory effect of M1-stimulation on clinical pain, motivated us to deepen our understanding of M1's role in pain modulation. We used Transcranial Magnetic Stimulation (TMS)-induced virtual lesion (VL) to interrupt with M1 activity during noxious heat pain. We hypothesized that TMS-VL will effect experimental pain ratings. Three VL protocols were applied consisting of single-pulse TMS to transiently interfere with right M1 activity: (1) VLM1- TMS applied to 11 subjects, 20 msec before the individual's first pain-related M1 peak activation, as determined by source analysis (sLORETA), (2) VL-50 (N = 16; TMS applied 50 ms prior to noxious stimulus onset), and (3) VL+150 (N = 16; TMS applied 150 ms after noxious stimulus onset). Each protocol included 3 conditions ('pain-alone', ' TMS-VL', and 'SHAM-VL'), each consisted of 30 noxious heat stimuli. Pain ratings were compared, in each protocol, for TMS-VL vs. SHAM-VL and vs. pain-alone conditions. Repeated measures analysis of variance, corrected for multiple comparisons revealed no significant differences in the pain ratings between the different conditions within each protocol. Therefore, our results from this exploratory study suggest that a single pulse TMS-induced VL that is targeted to M1 failed to interrupt experimental pain processing in the specific three stimulation timing examined here.

  2. Two-Copy Wavelength Conversion of an 80 Gbit/s Serial Data Signal Using Cross-Phase Modulation in a Silicon Nanowire and Detailed Pump-Probe Characterisation

    DEFF Research Database (Denmark)

    Ji, Hua; Cleary, C. S.; Dailey, J. M.

    2012-01-01

    We experimentally demonstrate 80 Gbit/s wavelength conversion to two copies by simultaneously extracting the blue- and red-shifted sidebands from XPM in a silicon nanowire. Bit error rates of 10-9 with only ~2 dB power penalty is achieved for both sidebands. Detailed pump-probe characterisation r...

  3. Full Multilayer Laue Lens for Focusing Hard X-rays

    International Nuclear Information System (INIS)

    Liu Chian; Shi, B.; Qian, J.; Conley, R.; Yan, H.; Wieczorek, M.; Macrander, A. T.; Maser, J.; Stephenson, G. B.

    2010-01-01

    Multilayer Laue Lenses (MLLs) were developed by us using dynamic diffraction effects to efficiently focus hard x-rays to very small spots. Using a partial MLL we were able to focus 19.5-keV hard x-rays to a line focus of 16 nm with an efficiency of 31%. A full MLL is a complete linear MLL structure. It can be fabricated by bonding two partial MLL wafers, or by growing the full structure using magnetron sputtering without bonding. A 40-μm full MLL, with a total of 5166 layers of WSi 2 and Si, has been successfully grown by sputter deposition. The layer thicknesses gradually vary from 4 nm to ∼400 nm and then back to 4 nm. Two coating runs were used to grow the full structure, one for each half. It took over 56 h for each run. A 100-μm nearly-full MLL was constructed by bonding. Each 50-μm half-structure has 1788 WSi 2 and Si layers with 12-nm to ∼32-nm thicknesses and ∼32-μm total thickness, followed by a thick WSi 2 layer of ∼17 μm, and an AuSn layer of ∼1 μm. Both full MLL structures survived dicing and polishing. The primary results demonstrate the feasibility and potential of a full MLL with a doubled numerical aperture and large beam acceptance for hard x-rays.

  4. Analysis of the diffraction pattern obtained by the Laue method

    International Nuclear Information System (INIS)

    Riquet, J. par; Bonnet, R.

    1978-01-01

    A computation method is presented which allows a rapid indexing of any unknown spot pattern obtained by back-reflection or transmission Laue methods. The Cartesian coordinates of n spots are measured in an orthonormal frame referred to the photographic film. Two spots 1 and 2 separated by a wide angular distance αsup(m) are carefully chosen. Their indices are assumed to be less than 5. The set (E) of all the pairs of planes (h 1 k 1 l 1 ) and (h 2 k 2 l 2 ) making an angle α close to αsup(m) is then computed. Since the pair of reflecting planes related to spots 1 and 2 belongs to (E), each computed pair of planes is tried, in order to determine the orientation of the crystal and to check whether the coordinates of the (n-2) other spots can be matched to dense planes of indices less than 8. If the uncertainty of the measurements is high or if n is too low, this method gives the possible orientations for the crystal. Plane indices less than 8 have been identified in cubic, tetragonal and orthorhombic crystals. (Auth.)

  5. Development of dynamic simulation code for fuel cycle of fusion reactor. 1. Single pulse operation simulation

    Energy Technology Data Exchange (ETDEWEB)

    Aoki, Isao; Seki, Yasushi [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment; Sasaki, Makoto; Shintani, Kiyonori; Kim, Yeong-Chan

    1997-11-01

    A dynamic simulation code for the fuel cycle of a fusion experimental reactor has been developed. The code follows the fuel inventory change with time in the plasma chamber and the fuel cycle system during a single pulse operation. The time dependence of the fuel inventory distribution is evaluated considering the fuel burn and exhaust in the plasma chamber, purification and supply functions. For each subsystem of the plasma chamber and the fuel cycle system, the fuel inventory equation is written based on the equation of state considering the function of fuel burn, exhaust, purification, and supply. The processing constants of subsystem for the steady states were taken from the values in the ITER Conceptual Design Activity (CDA) report. Using the code, the time dependence of the fuel supply and inventory depending on the burn state and subsystem processing functions are shown. (author)

  6. Single-pulse and multi-pulse femtosecond laser damage of optical single films

    International Nuclear Information System (INIS)

    Yuan Lei; Zhao Yuan'an; He Hongbo; Shao Jianda; Fan Zhengxiu

    2006-01-01

    Laser-induced damage of a single 500 nm HfO 2 film and a single 500 nm ZrO 2 film were studied with single- and multi-pulse femtosecond laser. The laser-induced damage thresholds (LIDT) of both samples by the 1-on-1 method and the 1000-on-1 method were reported. It was discovered that the LIDT of the HfO 2 single film was higher than that of the ZrO 2 single film by both test methods, which was explained by simple Keldysh's multiphoton ionization theory. The LIDT of multi-pulse was lower than that of single-pulse for both samples as a result of accumulative effect. (authors)

  7. Simultaneous, single-pulse, synchrotron x-ray imaging and diffraction under gas gun loading

    Energy Technology Data Exchange (ETDEWEB)

    Fan, D.; Luo, S. N., E-mail: sluo@pims.ac.cn [The Peac Institute of Multiscale Sciences, Chengdu, Sichuan 610031 (China); Key Laboratory of Advanced Technologies of Materials, Ministry of Education, Southwest Jiaotong University, Chengdu, Sichuan 610031 (China); Huang, J. W.; Zeng, X. L.; Li, Y.; E, J. C.; Huang, J. Y. [The Peac Institute of Multiscale Sciences, Chengdu, Sichuan 610031 (China); Sun, T.; Fezzaa, K. [Advanced Photon Source, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Wang, Z. [Physics Division P-25, Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States)

    2016-05-15

    We develop a mini gas gun system for simultaneous, single-pulse, x-ray diffraction and imaging under high strain-rate loading at the beamline 32-ID of the Advanced Photon Source. In order to increase the reciprocal space covered by a small-area detector, a conventional target chamber is split into two chambers: a narrowed measurement chamber and a relief chamber. The gas gun impact is synchronized with synchrotron x-ray pulses and high-speed cameras. Depending on a camera’s capability, multiframe imaging and diffraction can be achieved. The proof-of-principle experiments are performed on single-crystal sapphire. The diffraction spots and images during impact are analyzed to quantify lattice deformation and fracture; fracture is dominated by splitting cracks followed by wing cracks, and diffraction peaks are broadened likely due to mosaic spread. Our results demonstrate the potential of such multiscale measurements for studying high strain-rate phenomena at dynamic extremes.

  8. Timing Solution and Single-pulse Properties for Eight Rotating Radio Transients

    Energy Technology Data Exchange (ETDEWEB)

    Cui, B.-Y.; McLaughlin, M. A. [Department of Physics and Astronomy West Virginia University Morgantown, WV 26506 (United States); Boyles, J. [Department of Physics and Astronomy West Kentucky University Bowling Green, KY 42101 (United States); Palliyaguru, N. [Physics and Astronomy Department Texas Tech University Lubbock, TX 79409-1051 (United States)

    2017-05-01

    Rotating radio transients (RRATs), loosely defined as objects that are discovered through only their single pulses, are sporadic pulsars that have a wide range of emission properties. For many of them, we must measure their periods and determine timing solutions relying on the timing of their individual pulses, while some of the less sporadic RRATs can be timed by using folding techniques as we do for other pulsars. Here, based on Parkes and Green Bank Telescope (GBT) observations, we introduce our results on eight RRATs including their timing-derived rotation parameters, positions, and dispersion measures (DMs), along with a comparison of the spin-down properties of RRATs and normal pulsars. Using data for 24 RRATs, we find that their period derivatives are generally larger than those of normal pulsars, independent of any intrinsic correlation with period, indicating that RRATs’ highly sporadic emission may be associated with intrinsically larger magnetic fields. We carry out Lomb–Scargle tests to search for periodicities in RRATs’ pulse detection times with long timescales. Periodicities are detected for all targets, with significant candidates of roughly 3.4 hr for PSR J1623−0841 and 0.7 hr for PSR J1839−0141. We also analyze their single-pulse amplitude distributions, finding that log-normal distributions provide the best fits, as is the case for most pulsars. However, several RRATs exhibit power-law tails, as seen for pulsars emitting giant pulses. This, along with consideration of the selection effects against the detection of weak pulses, imply that RRAT pulses generally represent the tail of a normal intensity distribution.

  9. Timing Solution and Single-pulse Properties for Eight Rotating Radio Transients

    Science.gov (United States)

    Cui, B.-Y.; Boyles, J.; McLaughlin, M. A.; Palliyaguru, N.

    2017-05-01

    Rotating radio transients (RRATs), loosely defined as objects that are discovered through only their single pulses, are sporadic pulsars that have a wide range of emission properties. For many of them, we must measure their periods and determine timing solutions relying on the timing of their individual pulses, while some of the less sporadic RRATs can be timed by using folding techniques as we do for other pulsars. Here, based on Parkes and Green Bank Telescope (GBT) observations, we introduce our results on eight RRATs including their timing-derived rotation parameters, positions, and dispersion measures (DMs), along with a comparison of the spin-down properties of RRATs and normal pulsars. Using data for 24 RRATs, we find that their period derivatives are generally larger than those of normal pulsars, independent of any intrinsic correlation with period, indicating that RRATs’ highly sporadic emission may be associated with intrinsically larger magnetic fields. We carry out Lomb-Scargle tests to search for periodicities in RRATs’ pulse detection times with long timescales. Periodicities are detected for all targets, with significant candidates of roughly 3.4 hr for PSR J1623-0841 and 0.7 hr for PSR J1839-0141. We also analyze their single-pulse amplitude distributions, finding that log-normal distributions provide the best fits, as is the case for most pulsars. However, several RRATs exhibit power-law tails, as seen for pulsars emitting giant pulses. This, along with consideration of the selection effects against the detection of weak pulses, imply that RRAT pulses generally represent the tail of a normal intensity distribution.

  10. Developing a Laue Lens for Nuclear Astrophysics: The Challenge of Focusing Soft Gamma-rays

    Science.gov (United States)

    Barriere, Nicolas

    Soft gamma rays provide a unique window on the high-energy Universe, especially for studying nuclear astrophysics through nuclear line emission. However, the sensitivity of state-of-the-art gamma-ray telescopes is severely limited by the intense instrumental background when flown in space. A solution is to decouple the photon collection area from the photon detection area. Focusing source photons from a large collection area onto a small detector volume would dramatically improve the signal-to-noise ratio, and hence provide the long awaited sensitivity leap in this challenging energy band. Laue crystal diffraction can be utilized to focus soft gamma rays when configured in a Laue lens. While this technology has been demonstrated on balloon flights, the type of crystals used and the process of assembling many crystals into a lens have not been optimized yet. We propose to address all the technical aspects of the construction of a scientifically exploitable Laue lens in order to bring this technology to TRL-6. To this end, two small prototypes representative of the diversity of Laue lenses will be built and tested in relevant environments, leveraging the work accomplished under a previous APRA grant. This project will establish the real performances, the cost, and the construction duration of a full-scale lens, allowing us to propose a Laue lens telescope for suborbital or satellite missions.

  11. Feasibility of one-shot-per-crystal structure determination using Laue diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Cornaby, Sterling [School of Applied and Engineering Physics, Cornell University, Ithaca, New York (United States); CHESS (Cornell High Energy Synchrotron Source), Cornell University, Ithaca, New York (United States); Szebenyi, Doletha M. E. [MacCHESS (Macromolecular Diffraction Facilities at CHESS), Cornell University, Ithaca, New York (United States); Smilgies, Detlef-M. [CHESS (Cornell High Energy Synchrotron Source), Cornell University, Ithaca, New York (United States); Schuller, David J.; Gillilan, Richard; Hao, Quan [MacCHESS (Macromolecular Diffraction Facilities at CHESS), Cornell University, Ithaca, New York (United States); Bilderback, Donald H., E-mail: dhb2@cornell.edu [School of Applied and Engineering Physics, Cornell University, Ithaca, New York (United States); CHESS (Cornell High Energy Synchrotron Source), Cornell University, Ithaca, New York (United States)

    2010-01-01

    Structure determination was successfully carried out using single Laue exposures from a group of lysozyme crystals. The Laue method may be a viable option for collection of one-shot-per-crystal data from microcrystals. Crystal size is an important factor in determining the number of diffraction patterns which may be obtained from a protein crystal before severe radiation damage sets in. As crystal dimensions decrease this number is reduced, eventually falling to one, at which point a complete data set must be assembled using data from multiple crystals. When only a single exposure is to be collected from each crystal, the polychromatic Laue technique may be preferable to monochromatic methods owing to its simultaneous recording of a large number of fully recorded reflections per image. To assess the feasibility of solving structures using single Laue images from multiple crystals, data were collected using a ‘pink’ beam at the CHESS D1 station from groups of lysozyme crystals with dimensions of the order of 20–30 µm mounted on MicroMesh grids. Single-shot Laue data were used for structure determination by molecular replacement and correct solutions were obtained even when as few as five crystals were used.

  12. Feasibility of one-shot-per-crystal structure determination using Laue diffraction

    International Nuclear Information System (INIS)

    Cornaby, Sterling; Szebenyi, Doletha M. E.; Smilgies, Detlef-M.; Schuller, David J.; Gillilan, Richard; Hao, Quan; Bilderback, Donald H.

    2010-01-01

    Structure determination was successfully carried out using single Laue exposures from a group of lysozyme crystals. The Laue method may be a viable option for collection of one-shot-per-crystal data from microcrystals. Crystal size is an important factor in determining the number of diffraction patterns which may be obtained from a protein crystal before severe radiation damage sets in. As crystal dimensions decrease this number is reduced, eventually falling to one, at which point a complete data set must be assembled using data from multiple crystals. When only a single exposure is to be collected from each crystal, the polychromatic Laue technique may be preferable to monochromatic methods owing to its simultaneous recording of a large number of fully recorded reflections per image. To assess the feasibility of solving structures using single Laue images from multiple crystals, data were collected using a ‘pink’ beam at the CHESS D1 station from groups of lysozyme crystals with dimensions of the order of 20–30 µm mounted on MicroMesh grids. Single-shot Laue data were used for structure determination by molecular replacement and correct solutions were obtained even when as few as five crystals were used

  13. Effects of single pulse energy on the properties of ceramic coating prepared by micro-arc oxidation on Ti alloy

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jun-Hua [Department of Mechanical Engineering, Tsinghua University, Beijing 100084 (China); School of Materials Science and Engineering, Henan University of Science and Technology, Luoyang 471023 (China); Faculty of Mechanical and Electrical Engineering, Kunming University of Science and Technology, Kunming 650500 (China); Wang, Jin [Department of Mechanical Engineering, Tsinghua University, Beijing 100084 (China); Beijing Key Lab of Precision/Ultra-precision Manufacturing Equipments and Control, Beijing 100084 (China); Lu, Yan [School of Materials Science and Engineering, Henan University of Science and Technology, Luoyang 471023 (China); Du, Mao-Hua [Faculty of Mechanical and Electrical Engineering, Kunming University of Science and Technology, Kunming 650500 (China); Han, Fu-Zhu, E-mail: hanfuzhu@mail.tsinghua.edu.cn [Department of Mechanical Engineering, Tsinghua University, Beijing 100084 (China); Beijing Key Lab of Precision/Ultra-precision Manufacturing Equipments and Control, Beijing 100084 (China)

    2015-01-01

    Highlights: • Single pulse energy remarkably influences the properties of ceramic coating prepared by MAO on Ti alloy. • The accumulative time of impulse width is an important parameter in the scientific and rational measurement of the film forming law of ceramic coating. • The ceramic coating thickness approximately linearly increases with the cumulative time of impulse width. • Larger impulse width resulted in higher single pulse energy, film forming rates and thicker ceramic coating thickness. • The effects of single pulse energy on the micro-hardness and phase composition of ceramic coating are not as evident as those of frequency and duty cycle. - Abstract: The effects of single pulse energy on the properties of ceramic coating fabricated on a Ti–6Al–4V alloy via micro-arc oxidation (MAO) in aqueous solutions containing aluminate, phosphate, and some additives are investigated. The thickness, micro-hardness, surface and cross-sectional morphology, surface roughness, and compositions of the ceramic coating are studied using eddy current thickness meter, micro-hardness tester, JB-4C Precision Surface roughness meter, scanning electron microscopy (SEM) and X-ray diffraction (XRD). Single pulse energy remarkably influences the ceramic coating properties. The accumulative time of impulse width is an important parameter in the scientific and rational measurement of the film forming law of ceramic coating. The ceramic coating thickness approximately linearly increases with the cumulative time of impulse width. Larger impulse width resulted in higher single pulse energy, film forming rates and thicker ceramic coating thickness. The sizes of oxide particles, micro-pores and micro-cracks slightly increase with impulse width and single pulse energy. The main surface conversion products generated during MAO process in aqueous solutions containing aluminate are rutile TiO{sub 2}, anatase TiO{sub 2}, and a large amount of Al{sub 2}TiO{sub 5}. The effects of

  14. Designing and commissioning of a prototype double Laue monochromator at CHESS

    Science.gov (United States)

    Ko, J. Y. Peter; Oswald, Benjamin B.; Savino, James J.; Pauling, Alan K.; Lyndaker, Aaron; Revesz, Peter; Miller, Matthew P.; Brock, Joel D.

    2014-03-01

    High-energy X-rays are efficiently focused sagittally by a set of asymmetric Laue (transmission) crystals. We designed, built and commissioned a prototype double Laue monochromator ((111) reflection in Si(100)) optimized for high-energy X-rays (30-60 keV). Here, we report our design of novel prototype sagittal bender and highlight results from recent characterization experiments. The design of the bender combines the tuneable bending control afforded by previous leaf-spring designs with the stability and small size of a four-bar bender. The prototype monochromator focuses a 25 mm-wide white beam incident on the first monochromator crystal to a monochromatized 0.6 mm beam waist in the experimental station. Compared to the flux in the same focal spot with the Bragg crystal (without focusing), the prototype Laue monochromator delivered 85 times more at 30 keV.

  15. A simulation study on the focal plane detector of the LAUE project

    Science.gov (United States)

    Khalil, M.; Frontera, F.; Caroli, E.; Virgilli, E.; Valsan, V.

    2015-06-01

    The LAUE project, supported by the Italian Space Agency (ASI), is devoted to the development of a long focal length (even 20 m or longer) Laue lens for gamma ray astronomy between 80 and 600 keV. These lenses take advantage of Bragg diffraction to focus radiation onto a small spot drastically improving the signal to noise ratio as well as reducing the required size of the detector significantly. In this paper we present a Monte-Carlo simulation study with MEGALIB to optimize, for space applications, the detector size to achieve high detection efficiency, and to optimize the position resolution of the detector to reconstruct the Point Spread Function of the lens considered for the LAUE project. Then we will show simulations, using the SILVACO semiconductor simulation toolkit, on the optimized detector to estimate its capacitance per channel and depletion voltage. In all of the simulations, two materials were compared; a low density material (Silicon) and a high density material (Germanium).

  16. Designing and commissioning of a prototype double Laue monochromator at CHESS

    International Nuclear Information System (INIS)

    Ko, J Y Peter; Oswald, Benjamin B; Savino, James J; Pauling, Alan K; Lyndaker, Aaron; Revesz, Peter; Miller, Matthew P; Brock, Joel D

    2014-01-01

    High-energy X-rays are efficiently focused sagittally by a set of asymmetric Laue (transmission) crystals. We designed, built and commissioned a prototype double Laue monochromator ((111) reflection in Si(100)) optimized for high-energy X-rays (30-60 keV). Here, we report our design of novel prototype sagittal bender and highlight results from recent characterization experiments. The design of the bender combines the tuneable bending control afforded by previous leaf-spring designs with the stability and small size of a four-bar bender. The prototype monochromator focuses a 25 mm-wide white beam incident on the first monochromator crystal to a monochromatized 0.6 mm beam waist in the experimental station. Compared to the flux in the same focal spot with the Bragg crystal (without focusing), the prototype Laue monochromator delivered 85 times more at 30 keV.

  17. Relaxation dynamics of the LH2 complex from a photosynthetic purple bacterium Thiorhodospira sibirica studied by the near-IR femtosecond pump-probe method

    International Nuclear Information System (INIS)

    Razjivin, A P; Pishchal'nikov, R Yu; Kozlovskii, V S; Kompanets, V O; Chekalin, Sergei V; Moskalenko, A A; Makhneva, Z K

    2005-01-01

    Photoinduced changes in the absorption spectrum of the LH2 (B800-830-850) complex from a Thiorhodospira sibirica (Trs. sibirica) bacterium are studied by the pump-probe method. The complex has the anomalous absorption spectrum exhibiting three bands in the near-IR region at 793, 826.5, and 846.5 nm. At room temperature, the excitation energy transfer from the B800, B830, and B859 bands was detected with the time constants τ 1 ∼0.5 ps, τ 2 ∼2.5 ps, and τ 3 of the order of a few hundreds of picoseconds, respectively. A rapid energy transfer from the B830 band compared to energy transfer from the B850 band (τ 2 ||τ 3 ) suggests that all the three bands belong to the same complex (i.e., that the LH2 complex from Trs. sibirica is homogeneous). A slower energy transfer (by three - five times) from the B830 band of the LH2 complex from Trs. sibirica compared to energy transfer from the B800 band of the LH2 complexes (B800-850 and especially B800-820) from other purple bacteria suggests that the electronic structures of ensembles of bacteriochlorophyll molecules in these complexes are substantially different. (laser applications and other topics in quantum electronics)

  18. Ultrafast spin injection from Cd1-x Mn x Te magnetic barriers into a CdTe quantum well studied by pump-probe spectroscopy

    International Nuclear Information System (INIS)

    Aoshima, I.; Nishibayashi, K.; Souma, I.; Murayama, A.; Oka, Y.

    2006-01-01

    Spin injection from diluted magnetic semiconductor (DMS) barriers of Cd 1- x Mn x Te into a quantum well (QW) of CdTe is studied, by means of pump-probe absorption spectroscopy in magnetic fields. Fast decay characteristics of circularly polarized differential absorbances of spin-polarized excitons in the DMS barrier show the exciton injection time of 6 ps from the barriers into the QW. In accordance with the fast relaxation of the spin-polarized excitons from the barrier, we observe the rise of circular polarization degree for the differential absorption of the CdTe QW in magnetic fields, evidently indicating the spin injection. In addition, the circular polarization degree up to 0.3 is developed in the well immediately after pumping, originating from the fast relaxation of a heavy hole (hh) spin less than 0.2 ps, due to the giant Zeeman effect caused by the penetration of the hh wave function into the DMS barriers

  19. In-Situ Probing Plasmonic Energy Transfer in Cu(In, Ga)Se2 Solar Cells by Ultrabroadband Femtosecond Pump-Probe Spectroscopy.

    Science.gov (United States)

    Chen, Shih-Chen; Wu, Kaung-Hsiung; Li, Jia-Xing; Yabushita, Atsushi; Tang, Shih-Han; Luo, Chih Wei; Juang, Jenh-Yih; Kuo, Hao-Chung; Chueh, Yu-Lun

    2015-12-18

    In this work, we demonstrated a viable experimental scheme for in-situ probing the effects of Au nanoparticles (NPs) incorporation on plasmonic energy transfer in Cu(In, Ga)Se2 (CIGS) solar cells by elaborately analyzing the lifetimes and zero moment for hot carrier relaxation with ultrabroadband femtosecond pump-probe spectroscopy. The signals of enhanced photobleach (PB) and waned photoinduced absorption (PIA) attributable to surface plasmon resonance (SPR) of Au NPs were in-situ probed in transient differential absorption spectra. The results suggested that substantial carriers can be excited from ground state to lower excitation energy levels, which can reach thermalization much faster with the existence of SPR. Thus, direct electron transfer (DET) could be implemented to enhance the photocurrent of CIGS solar cells. Furthermore, based on the extracted hot carrier lifetimes, it was confirmed that the improved electrical transport might have been resulted primarily from the reduction in the surface recombination of photoinduced carriers through enhanced local electromagnetic field (LEMF). Finally, theoretical calculation for resonant energy transfer (RET)-induced enhancement in the probability of exciting electron-hole pairs was conducted and the results agreed well with the enhanced PB peak of transient differential absorption in plasmonic CIGS film. These results indicate that plasmonic energy transfer is a viable approach to boost high-efficiency CIGS solar cells.

  20. Scheme for femtosecond-resolution pump-probe experiments at XFELs with two-color ten GW-level X-ray pulses

    International Nuclear Information System (INIS)

    Geloni, Gianluca; Kocharyan, Vitali; Saldin, Evgeni

    2010-01-01

    This paper describes a scheme for pump-probe experiments that can be performed at LCLS and at the European XFEL and determines what additional hardware development will be required to bring these experiments to fruition. It is proposed to derive both pump and probe pulses from the same electron bunch, but from different parts of the tunable-gap baseline undulator. This eliminates the need for synchronization and cancels jitter problems. The method has the further advantage to make a wide frequency range accessible at high peak-power and high repetition-rate. An important feature of the proposed scheme is that the hardware requirement is minimal. Our technique is based in essence on the ''fresh'' bunch technique. For its implementation it is sufficient to substitute a single undulator module with short magnetic delay line, i.e. a weak magnetic chicane, which delays the electron bunch with respect to the SASE pulse of half of the bunch length in the linear stage of amplification. This installation does not perturb the baseline mode of operation. We present a feasibility study and we make exemplifications with the parameters of the SASE2 line of the European XFEL. (orig.)

  1. Rapid and Accurate Assembly Method for a New Laue Lens Prototype

    DEFF Research Database (Denmark)

    Wade, Colin; Barriere, Nicolas; Hanlon, Lorraine

    2015-01-01

    The Laue lens is a technology for gamma-ray astrophysics whereby gamma-rays of particular energies can be focused by a suitable arrangement of crystals. The Laue lens assembly station at UC Berkeley was used to build a technological demonstrator addressing the key issues of crystal mounting speed......, crystal position and orientation accuracy, and crystal reflectivity. The new prototype is a lens segment containing a total of 48 5 x 5 mm2 crystals - 36 Iron and 12 Aluminium. The segment is composed of 8 partial rings, each of which is aligned to diffract an energy between 95 and 130 keV from a source...

  2. Single-pulse x-ray diffraction using polycapillary optics for in situ dynamic diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Maddox, B. R., E-mail: maddox3@llnl.gov; Akin, M. C., E-mail: akin1@llnl.gov; Teruya, A.; Hunt, D.; Hahn, D.; Cradick, J. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Morgan, D. V. [National Security Technologies LLC, Los Alamos, New Mexico 87544 (United States)

    2016-08-15

    Diagnostic use of single-pulse x-ray diffraction (XRD) at pulsed power facilities can be challenging due to factors such as the high flux and brightness requirements for diffraction and the geometric constraints of experimental platforms. By necessity, the x-ray source is usually positioned very close, within a few inches of the sample. On dynamic compression platforms, this puts the x-ray source in the debris field. We coupled x-ray polycapillary optics to a single-shot needle-and-washer x-ray diode source using a laser-based alignment scheme to obtain high-quality x-ray diffraction using a single 16 ns x-ray pulse with the source >1 m from the sample. The system was tested on a Mo sample in reflection geometry using 17 keV x-rays from a Mo anode. We also identified an anode conditioning effect that increased the x-ray intensity by 180%. Quantitative measurements of the x-ray focal spot produced by the polycapillary yielded a total x-ray flux on the sample of 3.3 ± 0.5 × 10{sup 7} molybdenum Kα photons.

  3. Investigating emotional top down modulation of ambiguous faces by single pulse TMS on early visual cortices

    Directory of Open Access Journals (Sweden)

    Zachary Adam Yaple

    2016-06-01

    Full Text Available Top-down processing is a mechanism in which memory, context and expectation are used to perceive stimuli. For this study we investigated how emotion content, induced by music mood, influences perception of happy and sad emoticons. Using single pulse TMS we stimulated right occipital face area (rOFA, primary visual cortex (V1 and vertex while subjects performed a face-detection task and listened to happy and sad music. At baseline, incongruent audio-visual pairings decreased performance, demonstrating dependence of emotion while perceiving ambiguous faces. However, performance of face identification decreased during rOFA stimulation regardless of emotional content. No effects were found between Cz and V1 stimulation. These results suggest that while rOFA is important for processing faces regardless of emotion, V1 stimulation had no effect. Our findings suggest that early visual cortex activity may not integrate emotional auditory information with visual information during emotion top-down modulation of faces.

  4. Interaction of single-pulse laser energy with bow shock in hypersonic flow

    Directory of Open Access Journals (Sweden)

    Hong Yanji

    2014-04-01

    Full Text Available Pressure sensing and schlieren imaging with high resolution and sensitivity are applied to the study of the interaction of single-pulse laser energy with bow shock at Mach 5. An Nd:YAG laser operated at 1.06 μm, 100 mJ pulse energy is used to break down the hypersonic flow in a shock tunnel. Three-dimensional Navier–Stokes equations are solved with an upwind scheme to simulate the interaction. The pressure at the stagnation point on the blunt body is measured and calculated to examine the pressure variation during the interaction. Schlieren imaging is used in conjunction with the calculated density gradients to examine the process of the interaction. The results show that the experimental pressure at the stagnation point on the blunt body and schlieren imaging fit well with the simulation. The pressure at the stagnation point on the blunt body will increase when the transmission shock approaches the blunt body and decrease with the formation of the rarefied wave. Bow shock is deformed during the interaction. Quasi-stationary waves are formed by high rate laser energy deposition to control the bow shock. The pressure and temperature at the stagnation point on the blunt body and the wave drag are reduced to 50%, 75% and 81% respectively according to the simulation. Schlieren imaging has provided important information for the investigation of the mechanism of the interaction.

  5. Meterwavelength Single-pulse Polarimetric Emission Survey. III. The Phenomenon of Nulling in Pulsars

    Energy Technology Data Exchange (ETDEWEB)

    Basu, Rahul; Mitra, Dipanjan; Melikidze, George I., E-mail: rahulbasu.astro@gmail.com [Janusz Gil Institute of Astronomy, University of Zielona Góra, ul. Szafrana 2, 65–516 Zielona Góra (Poland)

    2017-09-10

    A detailed analysis of nulling was conducted for the pulsars studied in the Meterwavelength Single-pulse Polarimetric Emission Survey. We characterized nulling in 36 pulsars including 17 pulsars where the phenomenon was reported for the first time. The most dominant nulls lasted for a short duration, less than five periods. Longer duration nulls extending to hundreds of periods were also seen in some cases. A careful analysis showed the presence of periodicities in the transition from the null to the burst states in 11 pulsars. In our earlier work, fluctuation spectrum analysis showed multiple periodicities in 6 of these 11 pulsars. We demonstrate that the longer periodicity in each case was associated with nulling. The shorter periodicities usually originate from subpulse drifting. The nulling periodicities were more aligned with the periodic amplitude modulation, indicating a possible common origin for both. The most prevalent nulls last for a single period and can be potentially explained using random variations affecting the plasma processes in the pulsar magnetosphere. On the other hand, longer-duration nulls require changes in the pair-production processes, which need an external triggering mechanism for the changes. The presence of periodic nulling puts an added constraint on the triggering mechanism, which also needs to be periodic.

  6. Single-pulse and burst-mode ablation of gold films measured by quartz crystal microbalance

    Science.gov (United States)

    Andrusyak, Oleksiy G.; Bubelnik, Matthew; Mares, Jeremy; McGovern, Theresa; Siders, Craig W.

    2005-02-01

    Femtosecond ablation has several distinct advantages: the threshold energy fluence for the onset of damage and ablation is orders of magnitude less than for traditional nanosecond laser machining, and by virtue of the rapid material removal of approximately an optical penetration depth per pulse, femtosecond machined cuts can be cleaner and more precise than those made with traditional nanosecond or longer pulse lasers. However, in many materials of interest, especially metals, this limits ablation rates to 10-100 nm/pulse. We present the results of using multiple pulse bursts to significantly increase the per-burst ablation rate compared to a single pulse with the same integrated energy, while keeping the peak intensity of each individual pulse below the air ionization limit. Femtosecond ablation with pulses centered at 800-nm having integrated energy of up to 30 mJ per pulse incident upon thin gold films was measured via resonance frequency shifts in a gold-electrode-coated quartz-crystal oscillator. Measurements were performed using Michelson-interferometer-based burst generators, with up to 2 ns pulse separations, as well as pulse shaping by programmable acousto-optic dispersive filter (Dazzler from FastLite) with up to 2 ps pulse separations.

  7. Single-pulse CARS based multimodal nonlinear optical microscope for bioimaging.

    Science.gov (United States)

    Kumar, Sunil; Kamali, Tschackad; Levitte, Jonathan M; Katz, Ori; Hermann, Boris; Werkmeister, Rene; Považay, Boris; Drexler, Wolfgang; Unterhuber, Angelika; Silberberg, Yaron

    2015-05-18

    Noninvasive label-free imaging of biological systems raises demand not only for high-speed three-dimensional prescreening of morphology over a wide-field of view but also it seeks to extract the microscopic functional and molecular details within. Capitalizing on the unique advantages brought out by different nonlinear optical effects, a multimodal nonlinear optical microscope can be a powerful tool for bioimaging. Bringing together the intensity-dependent contrast mechanisms via second harmonic generation, third harmonic generation and four-wave mixing for structural-sensitive imaging, and single-beam/single-pulse coherent anti-Stokes Raman scattering technique for chemical sensitive imaging in the finger-print region, we have developed a simple and nearly alignment-free multimodal nonlinear optical microscope that is based on a single wide-band Ti:Sapphire femtosecond pulse laser source. Successful imaging tests have been realized on two exemplary biological samples, a canine femur bone and collagen fibrils harvested from a rat tail. Since the ultra-broad band-width femtosecond laser is a suitable source for performing high-resolution optical coherence tomography, a wide-field optical coherence tomography arm can be easily incorporated into the presented multimodal microscope making it a versatile optical imaging tool for noninvasive label-free bioimaging.

  8. Design of a high-pressure single pulse shock tube for chemical kinetic investigations

    International Nuclear Information System (INIS)

    Tranter, R. S.; Brezinsky, K.; Fulle, D.

    2001-01-01

    A single pulse shock tube has been designed and constructed in order to achieve extremely high pressures and temperatures to facilitate gas-phase chemical kinetic experiments. Postshock pressures of greater than 1000 atmospheres have been obtained. Temperatures greater than 1400 K have been achieved and, in principle, temperatures greater than 2000 K are easily attainable. These high temperatures and pressures permit the investigation of hydrocarbon species pyrolysis and oxidation reactions. Since these reactions occur on the time scale of 0.5--2 ms the shock tube has been constructed with an adjustable length driven section that permits variation of reaction viewing times. For any given reaction viewing time, samples can be withdrawn through a specially constructed automated sampling apparatus for subsequent species analysis with gas chromatography and mass spectrometry. The details of the design and construction that have permitted the successful generation of very high-pressure shocks in this unique apparatus are described. Additional information is provided concerning the diaphragms used in the high-pressure shock tube

  9. Innovation and optimization of a method of pump-probe polarimetry with pulsed laser beams in view of a precise measurement of parity violation in atomic cesium

    International Nuclear Information System (INIS)

    Chauvat, D.

    1997-10-01

    While Parity Violation (PV) experiments on highly forbidden transitions have been using detection of fluorescence signals; our experiment uses a pump-probe scheme to detect the PV signal directly on a transmitted probe beam. A pulsed laser beam of linear polarisation ε 1 excites the atoms on the 6S-7S cesium transition in a colinear electric field E || k(ex). The probe beam (k(pr) || k(ex)) of linear polarisation ε 2 tuned to the transition 7S-6P(3/2) is amplified. The small asymmetry (∼ 10 -6 ) in the gain that depends on the handedness of the tri-hedron (E, ε 1 , ε 2 ) is the manifestation of the PV effect. This is measured as an E-odd apparent rotation of the plane of polarization of the probe beam; using balanced mode polarimetry. New criteria of selection have been devised, that allow us to distinguish the true PV-signal against fake rotations due to electromagnetic interferences, geometrical effects, polarization imperfections, or stray transverse electric and magnetic fields. These selection criteria exploit the symmetry of the PV-rotation - linear dichroism - and the revolution symmetry of the experiment. Using these criteria it is not only possible to reject fake signals, but also to elucidate the underlying physical mechanisms and to measure the relevant defects of the apparatus. The present signal-to-noise ratio allows embarking in PV measurements to reach the 10% statistical accuracy. A 1% measurement still requires improvements. Two methods have been demonstrated. The first one exploits the amplification of the asymmetry at high gain - one major advantage provided by our detection method based on stimulated emission. The second method uses both a much higher incident intensity and a special dichroic component which magnifies tiny polarization rotations. (author)

  10. Creating von Laue patterns in crystal scattering with partially coherent sources

    NARCIS (Netherlands)

    Wang, Y.Y.D.; Kuebel, D.; Visser, T.D.; Wolf, E.

    2016-01-01

    When spatially coherent radiation is diffracted by a crystalline object, the field is scattered in specific directions, giving rise to so-called von Laue patterns. We examine the role of spatial coherence in this process. Using the first-order Born approximation, a general analytic expression for

  11. Impressions from a visit by the ASN of the Laue Langevin Institute research reactor in Grenoble

    International Nuclear Information System (INIS)

    Nifenecker, H.

    2011-01-01

    After having recalled some specific characteristics of the Laue Langevin Institute research reactor (fuel type, cooling system, power, fuel management, fuel storage pool), the author reports the examination of the emergency procedures and of the reactor maintenance. He describes two exercises which respectively simulated the occurrence of an earthquake and that of a flooding due to a dam breaching

  12. Influence of external actions on the Bragg-Laue diffraction of X-Rays

    CERN Document Server

    Gasparyan, L G; Grigoryan, A G

    2000-01-01

    The Bragg-Laue diffraction in finite size crystals under the influence of external actions (ultrasound, temperature gradient) is investigated experimentally. It is established that external actions ''charge for the worse'' the crystal quality, which leads to the broadening of the rocking curves and to the sharp decrease of intensity in the center of the reflection angular range.

  13. Development of a 3D CZT detector prototype for Laue Lens telescope

    DEFF Research Database (Denmark)

    Caroli, Ezio; Auricchio, Natalia; Del Sordo, Stefano

    2010-01-01

    We report on the development of a 3D position sensitive prototype suitable as focal plane detector for Laue lens telescope. The basic sensitive unit is a drift strip detector based on a CZT crystal, (~19×8 mm2 area, 2.4 mm thick), irradiated transversally to the electric field direction. The anode...

  14. Surprise in simplicity: an unusual spectral evolution of a single pulse GRB 151006A

    Science.gov (United States)

    Basak, R.; Iyyani, S.; Chand, V.; Chattopadhyay, T.; Bhattacharya, D.; Rao, A. R.; Vadawale, S. V.

    2017-11-01

    We present a detailed analysis of GRB 151006A, the first gamma-ray burst (GRB) detected by AstroSat Cadmium-Zinc-Telluride Imager (CZTI). We study the long-term spectral evolution by exploiting the capabilities of Fermi and Swift satellites at different phases, which is complemented by the polarization measurement with the CZTI. While the light curve of the GRB in different energy bands shows a simple pulse profile, the spectrum shows an unusual evolution. The first phase exhibits a hard-to-soft evolution until ∼16-20 s, followed by a sudden increase in the spectral peak reaching a few MeV. Such a dramatic change in the spectral evolution in the case of a single pulse burst is reported for the first time. This is captured by all models we used namely, Band function, blackbody+Band and two blackbodies+power law. Interestingly, the Fermi Large Area Telescope also detects its first photon (>100 MeV) during this time. This new injection of energy may be associated with either the beginning of afterglow phase, or a second hard pulse of the prompt emission itself that, however, is not seen in the otherwise smooth pulse profile. By constructing Bayesian blocks and studying the hardness evolution we find a good evidence for a second hard pulse. The Swift data at late epochs (>T90 of the GRB) also show a significant spectral evolution consistent with the early second phase. The CZTI data (100-350 keV), though having low significance (1σ), show high values of polarization in the two epochs (77-94 per cent), in agreement with our interpretation.

  15. Meterwavelength Single-pulse Polarimetric Emission Survey. IV. The Period Dependence of Component Widths of Pulsars

    Science.gov (United States)

    Skrzypczak, Anna; Basu, Rahul; Mitra, Dipanjan; Melikidze, George I.; Maciesiak, Krzysztof; Koralewska, Olga; Filothodoros, Alexandros

    2018-02-01

    The core component width in normal pulsars, with periods (P) > 0.1 s, measured at the half-power point at 1 GHz, has a lower boundary line (LBL) that closely follows the P ‑0.5 scaling relation. This result is of fundamental importance for understanding the emission process and requires extended studies over a wider frequency range. In this paper we have carried out a detailed study of the profile component widths of 123 normal pulsars observed in the Meterwavelength Single-pulse Polarimetric Emission Survey at 333 and 618 MHz. The components in the pulse profile were separated into core and conal classes. We found that at both frequencies, the core, as well as the conal component widths versus period, had a LBL that followed the P ‑0.5 relation with a similar lower boundary. The radio emission in normal pulsars has been observationally shown to arise from a narrow range of heights around a few hundred kilometers above the stellar surface. In the past the P ‑0.5 relation has been considered as evidence for emission arising from last open dipolar magnetic field lines. We show that the P ‑0.5 dependence only holds if the trailing and leading half-power points of the component are associated with the last open field line. In such a scenario we do not find any physical motivation that can explain the P ‑0.5 dependence for both core and conal components as evidence for dipolar geometry in normal pulsars. We believe the period dependence is a result of a currently unexplained physical phenomenon.

  16. Object-oriented identification of forested landslides with derivatives of single pulse LiDAR data

    Science.gov (United States)

    Van Den Eeckhaut, Miet; Kerle, Norman; Poesen, Jean; Hervás, Javier

    2012-11-01

    In contrast to the many studies that use expert-based analysis of LiDAR derivatives for landslide mapping in forested terrain, only few studies have attempted to develop (semi-)automatic methods for extracting landslides from LiDAR derivatives. While all these studies are pixel-based, it has not yet been tested whether object-oriented analysis (OOA) could be an alternative. This study investigates the potential of OOA using only single-pulse LiDAR derivatives, such as slope gradient, roughness and curvature to map landslides. More specifically, the focus is on both LiDAR data segmentation and classification of slow-moving landslides in densely vegetated areas, where spectral data do not allow accurate landslide identification. A multistage procedure has been developed and tested in the Flemish Ardennes (Belgium). The procedure consists of (1) image binarization and multiresolution segmentation, (2) classification of landslide parts (main scarps and landslide body segments) and non-landslide features (i.e. earth banks and cropland fields) with supervised support vector machines at the appropriate scale, (3) delineation of landslide flanks, (4) growing of a landslide body starting from its main scarp, and (5) final cleaning of the inventory map. The results obtained show that OOA using LiDAR derivatives allows recognition and characterization of profound morphologic properties of forested deep-seated landslides on soil-covered hillslopes, because more than 90% of the main scarps and 70% of the landslide bodies of an expert-based inventory were accurately identified with OOA. For mountainous areas with bedrock, on the other hand, creation of a transferable model is expected to be more difficult.

  17. SINGLE-PULSE RADIO OBSERVATIONS OF THE GALACTIC CENTER MAGNETAR PSR J1745–2900

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Zhen; Shen, Zhi-Qiang; Wu, Ya-Jun; Zhao, Rong-Bing; Fan, Qing-Yuan; Hong, Xiao-Yu; Jiang, Dong-Rong; Li, Bin; Liang, Shi-Guang; Ling, Quan-Bao; Liu, Qing-Hui; Qian, Zhi-Han; Zhang, Xiu-Zhong; Zhong, Wei-Ye; Ye, Shu-Hua [Shanghai Astronomical Observatory, Chinese Academy of Sciences, Shanghai 200030 (China); Wu, Xin-Ji [Department of Astronomy, Peking University, Beijing 100871 (China); Manchester, R. N. [CSIRO Astronomy and Space Science, P.O. Box 76, Epping, NSW 1710 (Australia); Weltevrede, P. [Jodrell Bank Centre for Astrophysics, School of Physics and Astronomy, University of Manchester, Manchester M13 9PL (United Kingdom); Yuan, Jian-Ping [Key Laboratory of Radio Astronomy, Chinese Academy of Sciences (China); Lee, Ke-Jia, E-mail: yanzhen@shao.ac.cn [Kavli Institute for Astronomy and Astrophysics, Peking University, Beijing 100871 (China)

    2015-11-20

    In this paper, we report radio observations of the Galactic Center magnetar PSR J1745–2900 at six epochs between 2014 June and October. These observations were carried out using the new Shanghai Tian Ma Radio Telescope at a frequency of 8.6 GHz. Both the flux density and integrated profile of PSR J1745–2900 show dramatic changes from epoch to epoch, showing that the pulsar was in its “erratic” phase. On MJD 56836, the flux density of this magnetar was about 8.7 mJy, which was 10 times larger than that reported at the time of discovery, enabling a single-pulse analysis. The emission is dominated by narrow “spiky” pulses that follow a log-normal distribution in peak flux density. From 1913 pulses, we detected 53 pulses whose peak flux densities are 10 times greater than that of the integrated profile. They are concentrated in pulse phase at the peaks of the integrated profile. The pulse widths at the 50% level of these bright pulses were between 0.°2 and 0.°9, much narrower than that of the integrated profile (∼12°). The observed pulse widths may be limited by interstellar scattering. No clear correlation was found between the widths and peak flux density of these pulses and no evidence was found for subpulse drifting. Relatively strong spiky pulses are also detected in the other five epochs of observation, showing the same properties as those detected in MJD 56836. These strong spiky pulses cannot be classified as “giant” pulses but are more closely related to normal pulse emission.

  18. Megajoule-class single-pulse KrF laser test facility as a logical step toward inertial fusion commercialization

    International Nuclear Information System (INIS)

    Harris, D.B.; Pendergrass, J.H.

    1985-01-01

    The cost and efficiency of megajoule-class KrF laser single pulse test facilities have been examined. A baseline design is described which illuminates targets with 5 MJ with shaped 10-ns pulses. The system uses 24 main amplifiers and operates with an optics operating fluence of 4.0 J/cm 2 . This system has 9.0% efficiency and costs $200/joule. Tradeoff studies indicate that large amplifier modules and high fluences lead to the lowest laser system costs, but that only a 20% cost savings can be realized by going to amplifier modules larger than 200 kJ and/or fluences greater than 4 J/cm 2 . The role of the megajoule-class single-pulse test facility towards inertial fusion commercialization will also be discussed

  19. Fabrication and optimization of the copper halide Laser's comparison of the double-discharge (Cu Cl) with the single-pulse operation (Cu Br)

    International Nuclear Information System (INIS)

    Sajad, B.; Behrozinia, S.; Nikzad, P.; Bassam, M. A.

    2009-01-01

    In this paper, the fabrication of a double-pulse copper chloride laser was investigated to study the effect of various parameters such as buffer gas pressure, temperature, and the delay time between two electrical discharge pulses, on laser output power. Moreover, a single-pulse copper bromide laser was fabricated to optimize the laser output power versus temperature, buffer gas pressure, and electrical input power and discharge frequency. The comparison of the results in single-pulse and double-pulse excitation indicates that the former is easier in operation and more power stability can be achieved using single pulse excitation.

  20. A neutron image plate quasi-Laue diffractometer for protein crystallography

    Energy Technology Data Exchange (ETDEWEB)

    Cipriani, F.; Castagna, J.C.; Wilkinson, C. [European Molecular Biology Laboratory, Grenoble (France)] [and others

    1994-12-31

    An instrument which is based on image plate technology has been constructed to perform cold neutron Laue crystallography on protein structures. The crystal is mounted at the center of a cylindrical detector which is 400mm long and has a circumference of 1000mm, with gadolinium oxide-containing image plates mounted on its exterior surface. Laue images registered on the plate are read out by rotating the drum and translating a laser read head parallel to the cylinder axis, giving a pixel size of 200{mu}m x 200{mu}m and a total read time of 5 minutes. Preliminary results indicate that it should be possible to obtain a complete data set from a protein crystal to atomic resolution in about two weeks.

  1. Fabrication of customizable wedged multilayer Laue lenses by adding a stress layer

    International Nuclear Information System (INIS)

    Niese, Sven; Krüger, Peter; Kubec, Adam; Laas, Roman; Gawlitza, Peter; Melzer, Kathleen; Braun, Stefan; Zschech, Ehrenfried

    2014-01-01

    Diffractive optics for hard X-rays feature superior properties in terms of resolution and efficiency, if volume diffraction effects are exploited all-over the aperture. For multilayer Laue lenses, preferably a wedged geometry is required to obtain this effect. We present an approach utilizing an additional stress layer to realize the necessary geometrical modifications where each lens can be customized to a selected photon energy independently of the given multilayer deposition. The quality of the deposition of the stress layer is evaluated using a laboratory X-ray microscope prior to its application at synchrotron radiation facilities with a special approach to measure the relative layer tilt at high spatial resolution. - Highlights: • Wedged multilayer Laue lenses were fabricated using an additional stress layer. • Each lens can be customized to any photon energy independently of the multilayer. • The relative layer tilt is measured using laboratory X-ray microscopy

  2. Zone compensated multilayer laue lens and apparatus and method of fabricating the same

    Science.gov (United States)

    Conley, Raymond P.; Liu, Chian Qian; Macrander, Albert T.; Yan, Hanfei; Maser, Jorg; Kang, Hyon Chol; Stephenson, Gregory Brian

    2015-07-14

    A multilayer Laue Lens includes a compensation layer formed in between a first multilayer section and a second multilayer section. Each of the first and second multilayer sections includes a plurality of alternating layers made of a pair of different materials. Also, the thickness of layers of the first multilayer section is monotonically increased so that a layer adjacent the substrate has a minimum thickness, and the thickness of layers of the second multilayer section is monotonically decreased so that a layer adjacent the compensation layer has a maximum thickness. In particular, the compensation layer of the multilayer Laue lens has an in-plane thickness gradient laterally offset by 90.degree. as compared to other layers in the first and second multilayer sections, thereby eliminating the strict requirement of the placement error.

  3. Nanometer Linear Focusing of Hard X Rays by a Multilayer Laue Lens

    International Nuclear Information System (INIS)

    Kang, H.C.; Stephenson, G.B.; Maser, J.; Liu, C.; Conley, R.; Macrander, A.T.; Vogt, S.

    2006-01-01

    We report on a type of linear zone plate for nanometer-scale focusing of hard x rays, a multilayer Laue lens (MLL), produced by sectioning a multilayer and illuminating it in Laue diffraction geometry. Because of its large optical depth, a MLL spans the diffraction regimes applicable to a thin Fresnel zone plate and a crystal. Coupled wave theory calculations indicate that focusing to 5 nm or smaller with high efficiency should be possible. Partial MLL structures with outermost zone widths as small as 10 nm have been fabricated and tested with 19.5 keV synchrotron radiation. Focal sizes as small as 30 nm with efficiencies up to 44% are measured

  4. Curved crystals for high-resolution focusing of X and gamma rays through a Laue lens

    Science.gov (United States)

    Guidi, Vincenzo; Bellucci, Valerio; Camattari, Riccardo; Neri, Ilaria

    2013-08-01

    Crystals with curved diffracting planes have been investigated as high-efficiency optical components for the realization of a Laue lens for satellite-borne experiments in astrophysics. At Sensor and Semiconductor Laboratory (Ferrara, Italy) a research and development plan to implement Si and Ge curved crystals by surface grooving technique has been undertaken. The method of surface grooving allows obtaining Si and Ge curved crystals with self-standing curvature, i.e., with no need for external bending device, which is a mandatory issue in satellite-borne experiments. Si and Ge grooved crystals have been characterized by X-ray diffraction at ESRF and ILL to prove their functionality for a high-reflectivity Laue lens.

  5. Characterization of ion beam irradiated 304 stainless steel utilizing nanoindentation and Laue microdiffraction

    Energy Technology Data Exchange (ETDEWEB)

    Lupinacci, A. [Department of Materials Science and Engineering, University of California, Berkeley, CA (United States); Chen, K., E-mail: kchenlbl@gmail.com [Center for Advancing Materials Performance from the Nanoscale (CAMP-Nano), State Key Laboratory for Mechanical Behavior of Materials, Xi’an Jiaotong University, Xi’an, Shaanxi 710049 (China); Li, Y. [Center for Advancing Materials Performance from the Nanoscale (CAMP-Nano), State Key Laboratory for Mechanical Behavior of Materials, Xi’an Jiaotong University, Xi’an, Shaanxi 710049 (China); Kunz, M. [Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Jiao, Z.; Was, G.S. [Department of Nuclear Engineering, University of Michigan, Ann Arbor, MI (United States); Abad, M.D. [Department of Nuclear Engineering, University of California, Berkeley, CA (United States); Minor, A.M. [Department of Materials Science and Engineering, University of California, Berkeley, CA (United States); National Center for Electron Microscopy, The Molecular Foundry, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Hosemann, P., E-mail: Peterh@berkeley.edu [Department of Nuclear Engineering, University of California, Berkeley, CA (United States)

    2015-03-15

    Characterizing irradiation damage in materials utilized in light water reactors is critical for both material development and application reliability. Here we use both nanoindentation and Laue microdiffraction to characterize both the mechanical response and microstructure evolution due to irradiation. Two different irradiation conditions were considered in 304 stainless steel: 1 dpa and 10 dpa. In addition, an annealed condition of the 10 dpa specimen for 1 h at 500 °C was evaluated. Nanoindentation revealed an increase in hardness due to irradiation and also revealed that hardness saturated in the 10 dpa case. Broadening using Laue microdiffraction peaks indicates a significant plastic deformation in the irradiated area that is in good agreement with both the SRIM calculations and the nanoindentation results.

  6. First results of the EXILL and FATIMA campaign at the Institut Laue Langevin

    Energy Technology Data Exchange (ETDEWEB)

    Jolie, Jan; Regis, Jean-Marc; Saed-Samii, Nima; Warr, Nigel [IKP, Universitaet zu Koeln, Zuelpicher Str. 77, 50937 Koeln (Germany); Wilmsen, Dennis [IKP, Universitaet zu Koeln, Zuelpicher Str. 77, 50937 Koeln (Germany); GANIL, BP 55027 (France); France, Gilles de; Clement, Emmanuel [GANIL, BP 55027 (France); Blanc, Aurelien; Jentschel, Michael; Koester, Uli; Mutti, Paolo; Soldner, Thorsten [ILL, 71 Av. des Martyrs, 38042 Grenoble (France); Simpson, Gary [University of Western Scotland, Paisley, PA1 2BE (United Kingdom); UIrban, Waldek [Faculty of Physics, University of Warsaw, 02-093 Warsaw (Poland); Bruce, Alison; Lalskovski, Stefan [SCEM, University of Brighton, Brighton BN2 4GJ (United Kingdom); Fraile, Luis [Grupo de Fisica Nuclear, Universidad Complutese, 28040 Madrid (Spain); Kroell, Thorsten [Institut fuer Kernphysik, TU Darmstadt, Darmstadt (Germany); Podolyak, Zsolt; Regan, Patrick [Dept. of Physics, University of Surrey, Guildford GU2 7XH (United Kingdom); Korten, Wolfram [CEA, Centre de Saclay, IRFU, 91191 Gif-sur-Yvette (France); Ur, Calin; Marginean, Nicu [Horia Hulubei NIPNE, 77125 Bucharest (Romania)

    2015-07-01

    At the PF1B cold neutron beam line at the Institut Laue Langevin the EXILL and FATIMA array consisting of 8 EXOGAM clover Ge detectors and 16 LaBr3(Ce) scintillators was used for the measurement of lifetimes using the generalised centroid difference method. The studied nuclei were formed by the (n,γ) and (n,fission) reactions. We report on the set-up and present first results on {sup 90}Zr and {sup 196}Pt.

  7. Optimization of a multilayer Laue lens system for a hard x-ray nanoprobe

    International Nuclear Information System (INIS)

    Jiang, Hui; Wang, Hua; Mao, Chengwen; Li, Aiguo; He, Yan; Dong, Zhaohui; Zheng, Yi

    2014-01-01

    Detailed designs of a multilayer Laue lens system for a hard x-ray nanoprobe, including flat and wedged types, are presented, to realize nanoscale point focus and high diffraction efficiency simultaneously. The difficulty of movement and alignment for lens, aperture and sample are considered in the optimization process. Considering the practical requirements of future experiments, the features of the beamline and the structural imperfections, the working energy range, the beam vibration and structural errors are estimated and discussed. (paper)

  8. Focusing of hard x-rays to 16 nanometers with a multilayer Laue lens

    International Nuclear Information System (INIS)

    Kang, Hyon Chol; Yan Hanfei; Winarski, Robert P.; Holt, Martin V.; Maser, Joerg; Liu Chian; Conley, Ray; Vogt, Stefan; Macrander, Albert T.; Stephenson, G. Brian

    2008-01-01

    We report improved results for hard x-ray focusing using a multilayer Laue lens (MLL). We have measured a line focus of 16 nm width with an efficiency of 31% at a wavelength λ=0.064 nm (19.5 keV) using a partial MLL structure with an outermost zone width of 5 nm. The results are in good agreement with the theoretically predicted performance

  9. A simulation study on the focal plane detector of the LAUE project

    International Nuclear Information System (INIS)

    Khalil, M.; Frontera, F.; Caroli, E.; Virgilli, E.; Valsan, V.

    2015-01-01

    The LAUE project, supported by the Italian Space Agency (ASI), is devoted to the development of a long focal length (even 20 m or longer) Laue lens for gamma ray astronomy between 80 and 600 keV. These lenses take advantage of Bragg diffraction to focus radiation onto a small spot drastically improving the signal to noise ratio as well as reducing the required size of the detector significantly. In this paper we present a Monte-Carlo simulation study with MEGALIB to optimize, for space applications, the detector size to achieve high detection efficiency, and to optimize the position resolution of the detector to reconstruct the Point Spread Function of the lens considered for the LAUE project. Then we will show simulations, using the SILVACO semiconductor simulation toolkit, on the optimized detector to estimate its capacitance per channel and depletion voltage. In all of the simulations, two materials were compared; a low density material (Silicon) and a high density material (Germanium). - Highlights: • The quantized Hall plateaus and Shubnikov de Haas oscillations in transition metal doped topological insulators are observed. • The evidence of a two-dimensional/layered transport of the bulk electrons is reported. • An obvious ferromagnetism in doped topological insulators is observed. • Care should be taken to pindown the transport of the topological SS in topological insulators

  10. A simulation study on the focal plane detector of the LAUE project

    Energy Technology Data Exchange (ETDEWEB)

    Khalil, M., E-mail: mkhalil@in2p3.fr [APC Laboratory, 10 rue Alice Domon et Léonie Duquet, 75205 Paris Cedex 13 (France); Department of Physics and Earth Sciences, University of Ferrara, Via Saragat, 1, 44100 Ferrara (Italy); Frontera, F. [Department of Physics and Earth Sciences, University of Ferrara, Via Saragat, 1, 44100 Ferrara (Italy); INAF/IASF-Bologna, Via P. Gobetti 101, Bologna (Italy); Caroli, E. [INAF/IASF-Bologna, Via P. Gobetti 101, Bologna (Italy); Virgilli, E.; Valsan, V. [Department of Physics and Earth Sciences, University of Ferrara, Via Saragat, 1, 44100 Ferrara (Italy)

    2015-06-21

    The LAUE project, supported by the Italian Space Agency (ASI), is devoted to the development of a long focal length (even 20 m or longer) Laue lens for gamma ray astronomy between 80 and 600 keV. These lenses take advantage of Bragg diffraction to focus radiation onto a small spot drastically improving the signal to noise ratio as well as reducing the required size of the detector significantly. In this paper we present a Monte-Carlo simulation study with MEGALIB to optimize, for space applications, the detector size to achieve high detection efficiency, and to optimize the position resolution of the detector to reconstruct the Point Spread Function of the lens considered for the LAUE project. Then we will show simulations, using the SILVACO semiconductor simulation toolkit, on the optimized detector to estimate its capacitance per channel and depletion voltage. In all of the simulations, two materials were compared; a low density material (Silicon) and a high density material (Germanium). - Highlights: • The quantized Hall plateaus and Shubnikov de Haas oscillations in transition metal doped topological insulators are observed. • The evidence of a two-dimensional/layered transport of the bulk electrons is reported. • An obvious ferromagnetism in doped topological insulators is observed. • Care should be taken to pindown the transport of the topological SS in topological insulators.

  11. Wavelength dependence of the single pulse femtosecond laser ablation threshold of indium phosphide in the 400-2050 nm range

    International Nuclear Information System (INIS)

    Borowiec, A.; Tiedje, H.F.; Haugen, H.K.

    2005-01-01

    We present single pulse femtosecond laser ablation threshold measurements of InP obtained by optical, scanning electron, and atomic force microscopy. The experiments were conducted with laser pulses 65-175 fs in duration, in the wavelength range from 400 to 2050 nm, covering the photon energy region above and below the bandgap of InP. The ablation thresholds determined from depth and volume measurements varied from 87 mJ/cm 2 at 400 nm to 250 mJ/cm 2 at 2050 nm. In addition, crater depths and volumes were measured over a range of laser fluences extending well above the ablation threshold

  12. Exciton lifetime and spin dynamics in type-I In1−xAlxAs/Ga0.67Al0.33As quantum dots: Photoluminescence and pump-probe experiments

    International Nuclear Information System (INIS)

    Ben Daly, A.; Bernardot, F.; Barisien, T.; Galopin, E.; Lemaître, A.; Maaref, M.A.; Testelin, C.

    2015-01-01

    The exciton lifetime and spin relaxation have been studied in self-assembled In 1−x Al x As/Ga 0.67 Al 0.33 As quantum dots (QDs). Time-resolved photoluminescence and resonant pump-probe measurements were performed, at variable temperature and for different QD aluminium compositions. At low temperature, a long exciton-spin relaxation time has been measured, in agreement with the QD zero-dimensional confinement and the quenching of the relaxation mechanisms. The existence of a quasi-2D regime, in sample with a high QD density, has been observed. The importance of thermally-activated processes toward excited states is also evidenced, for QDs with different compositions and sizes. - Highlights: • The exciton lifetime and spin relaxation have been studied in In 1−x Al x As/Ga 0.67 Al 0.33 As quantum dot (QD). • Time-resolved photoluminescence (TRPL) and pump-probe measurements were performed, at variable temperature and for different QD aluminium compositions. • From the PL decay time, several thermal activation processes, related to 0D or 2D regime, or dependending on collective mechanisms. • The importance of thermal activated processes toward excited states is also evidenced, for QD with different compositions and sizes

  13. Single-pulse characteristics of the Xe(L) amplifier on the Xe35+ (3d→2p) transition array at λ ≅ 2.86 A

    International Nuclear Information System (INIS)

    Borisov, Alex B; Song Xiangyang; Zhang Ping; McCorkindale, John C; Khan, Shahab F; De Jonghe, Richard; Poopalasingam, Sankar; Zhao, Ji; Boyer, Keith; Rhodes, Charles K

    2006-01-01

    The triple comparison of (1) single-pulse spectral data, recorded with a CCD-equipped von Hamos spectrometer both axially and transversely; (2) axially measured time-integrated spectra registered on a film and (3) single-pulse x-ray images of the morphology of the self-trapped plasma channel, recorded simultaneously with the single-pulse spectra, establishes several leading characteristics of the saturated amplification observed on the Xe 35+ transition array at λ ≅ 2.86 A. The chief findings are (α) absolute positive correlation of amplification with the formation of a plasma channel, (β) a perfect spectral match of the amplified transitions in the comparison of axially recorded single-pulse and time-integrated film data and (γ) exact spectral correspondence of both the axially registered single-pulse and time-integrated film data with single-pulse transversely measured spectra exhibiting deep spectral hole burning at the position of the Xe 35+ array. (letter to the editor)

  14. Continuous single pulse resolved measurement of beam diameters at 200 kHz using optical transmission filters

    Science.gov (United States)

    Fruechtenicht, Johannes; Letsch, Andreas; Voss, Andreas; Abdou Ahmed, Marwan; Graf, Thomas

    2012-02-01

    We present a novel laser beam measurement setup which allows the determination of the beam diameter for each single pulse of a pulsed laser beam at repetition rates of up to 200 kHz. This is useful for online process-parameter control e.g. in micromachining or for laser source characterization. Basically, the developed instrument combines spatial transmission filters specially designed for instantaneous optical determination of the second order moments of the lateral intensity distribution of the light beam and photodiodes coupled to customized electronics. The acquisition is computer-based, enabling real-time operation for online monitoring or control. It also allows data storage for a later analysis and visualization of the measurement results. The single-pulse resolved beam diameter can be measured and recorded without any interruption for an unlimited number of pulses. It is only limited by the capacity of the data storage means. In our setup a standard PC and hard-disk provided 2 hours uninterrupted operation and recording of varying beam diameters at 200 kHz. This is about three orders of magnitude faster than other systems. To calibrate our device we performed experiments in cw and pulsed regimes and the obtained results were compared to those obtained with a commercial camera based system. Only minor deviations of the beam diameter values between the two instruments were observed, proving the reliability of our approach.

  15. A RD-ESPRIT algorithm for coherent DOA estimation in monostatic MIMO radar using a single pulse

    Science.gov (United States)

    Chen, Chen; Zhang, Xiaofei

    2014-08-01

    This paper discusses the problem of coherent direction of arrival (DOA) estimation in a monostatic multi-input multi-output (MIMO) radar using a single pulse, and proposes a reduced dimension (RD)-estimation of signal parameters via rotational invariance techniques (ESPRIT) algorithm. We reconstruct the received data and then utilise it to construct a set of Toeplitz matrices. After that, we use RD-ESPRIT to obtain the DOAs of the sources. The proposed algorithm is effective for coherent angle estimation based on a single pulse, and it has much better angle estimation performance than the forward backward spatial smoothing (FBSS)-ESPRIT algorithm and the ESPRIT-like of Li, as well as very close angle estimation performance to the ESPRIT-like of Han. For complexity comparison, our algorithm has very close complexity to the FBSS-ESPRIT algorithm, and lower complexity than the ESPRIT-like of Han and the ESPRIT-like of Li. Simulation results present the effectiveness and improvement of our approach.

  16. Secondary plasma formation after single pulse laser ablation underwater and its advantages for laser induced breakdown spectroscopy (LIBS).

    Science.gov (United States)

    Gavrilović, M R; Cvejić, M; Lazic, V; Jovićević, S

    2016-06-07

    In this work we present studies of spatial and temporal plasma evolution after single pulse ablation of an aluminium target in water. The laser ablation was performed using 20 ns long pulses emitted at 1064 nm. The plasma characterization was performed by fast photography, the Schlieren technique, shadowgraphy and optical emission spectroscopy. The experimental results indicate the existence of two distinct plasma stages: the first stage has a duration of approximately 500 ns from the laser pulse, and is followed by a new plasma growth starting from the crater center. The secondary plasma slowly evolves inside the growing vapor bubble, and its optical emission lasts over several tens of microseconds. Later, the hot glowing particles, trapped inside the vapor cavity, were detected during the whole cycle of the bubble, where the first collapse occurs after 475 μs from the laser pulse. Differences in the plasma properties during the two evolution phases are discussed, with an accent on the optical emission since its detection is of primary importance for LIBS. Here we demonstrate that the LIBS signal quality in single pulse excitation underwater can be greatly enhanced by detecting only the secondary plasma emission, and also by applying long acquisition gates (in the order of 10-100 μs). The presented results are of great importance for LIBS measurements inside a liquid environment, since they prove that a good analytical signal can be obtained by using nanosecond pulses from a single commercial laser source and by employing cost effective, not gated detectors.

  17. Quasi-mosaicity of (311) planes in silicon and its use in a Laue lens with high-focusing power

    Science.gov (United States)

    Camattari, Riccardo; Paternò, Gianfranco; Bellucci, Valerio; Guidi, Vincenzo

    2014-12-01

    (311) curved planes can be exploited for efficiently focus hard X-rays. With this purpose, a self-standing bent crystal was manufactured at the Sensor and Semiconductor Laboratory of Ferrara (Italy). The crystal was designed as an optical component for a X-ray concentrator such as a Laue lens. The curvature of (311) planes was obtained through the quasi-mosaic effect. The diffraction efficiency of the sample was tested at the Institut Laue Langevin of Grenoble (France) by using a collimated monochromatic X-ray beam. This was the first prove of the diffraction properties of (311) quasi-mosaic planes. Diffraction efficiency resulted 35 % with a 182 keV X-ray beam, in agreement with the theoretical expectation. It corresponded to a reflectivity of 33 %. While the chosen orientation is not the most performing lying of planes, it can be used, in addition to smaller-index planes, in order to raise the total effective area of a Laue lens. To quantify it, a Laue lens based on quasi-mosaic silicon and germanium crystals, exploiting (111), (422) and (311) diffracting planes, was achieved and simulated with the LaueGen code.

  18. First results of the (n,gamma) EXILL campaigns at the Institut Laue Langevin

    Energy Technology Data Exchange (ETDEWEB)

    Jolie, Jan; Regis, Jean-Marc; Wilmsen, Dennis; Ahmed, Samer; Pfeiffer, Michael; Saed Samii, Nima; Warr, Nigel [Institut fuer Kernphysik, Universitaet zu Koeln, Zuelpicher Str 77, 50937 Koeln (Germany); Thirolf, Peter; Habs, Dieter [Fakultaet fuer Physik, Ludwig Maximilian Universitaet, 85748 Garching (Germany); Collaboration: EXILL Collaboration; FATIMA Collaboration

    2014-07-01

    At the PF1B cold neutron beam line at the Institut Laue Langevin the EXILL array consisting of EXOGAM, GASP and LOHENGRIN detectors was used to perform (n,γ) measurements under very high coincidence rates. About ten different reactions were then measured in autumn 2012. In spring 2013 the EXOGAM array was combined with 16 LaBr{sub 3}(Ce) scintillators in the FATIMA rate at EXILL campaign for the measurement of lifetimes using the generalised centroid difference method. We report on the properties of both set-ups and present first results on Pt isotopes from both campaigns.

  19. Focusing performance of a multilayer Laue lens with layer placement error described by dynamical diffraction theory.

    Science.gov (United States)

    Hu, Lingfei; Chang, Guangcai; Liu, Peng; Zhou, Liang

    2015-07-01

    The multilayer Laue lens (MLL) is essentially a linear zone plate with large aspect ratio, which can theoretically focus hard X-rays to well below 1 nm with high efficiency when ideal structures are used. However, the focusing performance of a MLL depends heavily on the quality of the layers, especially the layer placement error which always exists in real MLLs. Here, a dynamical modeling approach, based on the coupled wave theory, is proposed to study the focusing performance of a MLL with layer placement error. The result of simulation shows that this method can be applied to various forms of layer placement error.

  20. In-phase and anti-phase interference fringes in Laue case

    International Nuclear Information System (INIS)

    Negishi, Riichirou; Fukamachi, Tomoe; Yoshizawa, Masami; Hirano, Kenji; Hirano, Keiichi; Kawamura, Takaaki

    2009-01-01

    By using X-rays from synchrotron radiation, we measured the rocking curves due to only the imaginary part of the atomic scattering factor in Laue case. The interference fringes are observed which are totally different from the Pendelloesung fringe. The fringes of the diffracted and transmitted rocking curves are in-phase with each other. We studied the origin of the in-phase fringes by using the complex dispersion surface and the electric field in the crystal, and also the relation with a coupled pendulum. (Abstract Copyright [2009], Wiley Periodicals, Inc.)

  1. Identification of {2 anti 1 anti 10} and {10 anti 10} Laue patterns of hexagonal and rhombohedral silicon carbide polytypes

    International Nuclear Information System (INIS)

    Yoganathan, M.; Suttrop, W.; Devaty, R.P.; Choyke, W.J.

    1994-01-01

    The development of epitaxic and bulk-grown semiconductor SiC exhibiting uniform polytype phase homogeneity is critically dependent upon the accurate identification of crystallographic orientations corresponding to the desired polytype. In this paper, experimental transmission Laue photographs as well as computer-generated transmission Laue patterns are presented for {2 anti 1 anti 10} and {10 anti 10} faces of the 4H, 6H and 15R polytypes of silicon carbide. The transmission patterns permit easy recognition of polytypes and crystal orientations. (orig.)

  2. Ultrafast supercontinuum fiber-laser based pump-probe scanning magneto-optical Kerr effect microscope for the investigation of electron spin dynamics in semiconductors at cryogenic temperatures with picosecond time and micrometer spatial resolution.

    Science.gov (United States)

    Henn, T; Kiessling, T; Ossau, W; Molenkamp, L W; Biermann, K; Santos, P V

    2013-12-01

    We describe a two-color pump-probe scanning magneto-optical Kerr effect microscope which we have developed to investigate electron spin phenomena in semiconductors at cryogenic temperatures with picosecond time and micrometer spatial resolution. The key innovation of our microscope is the usage of an ultrafast "white light" supercontinuum fiber-laser source which provides access to the whole visible and near-infrared spectral range. Our Kerr microscope allows for the independent selection of the excitation and detection energy while avoiding the necessity to synchronize the pulse trains of two separate picosecond laser systems. The ability to independently tune the pump and probe wavelength enables the investigation of the influence of excitation energy on the optically induced electron spin dynamics in semiconductors. We demonstrate picosecond real-space imaging of the diffusive expansion of optically excited electron spin packets in a (110) GaAs quantum well sample to illustrate the capabilities of the instrument.

  3. Sampling system for fast single pulses; Realisation d'un dispositif d'echantillonnage d'un signal bref unique

    Energy Technology Data Exchange (ETDEWEB)

    Zenatti, D [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1969-07-01

    Development of a device for the enlargement of the domain of application of classical oscilloscopes to the observation of fast single pulses by application of the sampling principle. Its principal characteristics are: Bandwidth of 700 MHz; Maximum sensibility of 50 mV; Maximum amplitude of input signal of {+-} 1 V; Number of samples of 16; Samples separation of 0,2 ns. (author) [French] Realisation d'un dispositif permettant d'elargir le domaine d'utilisation des oscilloscopes classiques en appliquant le principe de l'echantillonnage a l'observation d'un signal bref unique. Les principales caracteristiques sont les suivantes: Bande passante de 700 MHz; Sensibilite maximale de 50 mV; Amplitude maximale du signal a echantillonner de {+-} 1 V; Nombre de points d'echantillonnage de 16; Pas d'echantillonnage de 0,2 ns. (auteur)

  4. 15N incorporation into organ proteins of newborn rats following single pulse-labelling with different tracers

    International Nuclear Information System (INIS)

    Wutzke, K.D.; Plath, C.; Richter, I.; Heine, W.; Zhukova, T.P.; Sorokina, E.G.; Friedrich, M.

    1987-01-01

    A short-chain 15 N-peptide mixture characterized by an average chain length of 2.3 was obtained when 15 N-labelled yeast protein was hydrolyzed enzymatically by thermitase from Thermoactinomyces vulgaris. Fifteen newborn Wistar rats were given a single pulse of [ 15 N]glycine. [ 15 N]H 4 Cl and [ 15 N]yeast protein thermitasehydrolysate (YPTH) in a dosage of 50 mg 15 N excess kg -1 by gastric tube. In comparison with [ 15 N]glycine the 15 N incorporation rates of brain, muscle and liver were approximately 150% higher after [ 15 N]YPTH application. Uniform labelling, high 15 N enrichment, almost complete absorption, avoidance of imbalances and the low price make this tracer substance superior to other tracers conventionally used for organ labelling. (author)

  5. Specific features of a single-pulse sliding discharge in neon near the threshold for spark breakdown

    Science.gov (United States)

    Trusov, K. K.

    2017-08-01

    Experimental data on the spatial structure of a single-pulse sliding discharge in neon at voltages below, equal to, and above the threshold for spark breakdown are discussed. The experiments were carried at gas pressures of 30 and 100 kPa and different polarities of the discharge voltage. Photographs of the plasma structure in two discharge chambers with different dimensions of the discharge zone and different thicknesses of an alumina dielectric plate on the surface of which the discharge develops are inspected. Common features of the prebreakdown discharge and its specific features depending on the voltage polarity and gas pressure are analyzed. It is shown that, at voltages below the threshold for spark breakdown, a low-current glow discharge with cathode and anode spots develops in the electrode gap. Above the breakdown threshold, regardless of the voltage polarity, spark channels directed from the cathode to the anode develop against the background of a low-current discharge.

  6. The Israeli EA-FEL Upgrade Towards Long Pulse Operation for Ultra-High Resolution Single Pulse Coherent Spectroscopy

    CERN Document Server

    Gover, A; Kanter, M; Kapilevich, B; Litvak, B; Peleg, S; Socol, Y; Volshonok, M

    2005-01-01

    The Israeli Electrostatic Accelerator FEL (EA-FEL) is now being upgraded towards long pulse (1005s) operation and ultra-high resolution (10(-6)) single pulse coherent spectroscopy. We present quantitative estimations regarding the applications of controlled radiation chirp for spectroscopic applications with pulse-time Fourier Transform limited spectral resolution. Additionally, we describe a novel extraction-efficiency-improving scheme based on increase of accelerating voltage (boosting) after saturation is achieved. The efficiency of the proposed scheme is confirmed by theoretical and numerical calculations. The latter are performed using software, based on 3D space-frequency domain model. The presentation provides an overview of the upgrade status: the high-voltage terminal is being reconfigured to accept the accelerating voltage boost system; a new broad band low-loss resonator is being manufactured; multi-stage depressed collector is assembled.

  7. A study on structural changes in protein by time-division type Laue method

    International Nuclear Information System (INIS)

    Morimoto, Hideki

    1995-01-01

    In order to know the physiological roles of proteins, it is important to investigate the intermediate states of their structural changes. The sizes of proteins are generally several tens angstrom(A). Considering the resolution, only x-ray crystal analysis can be used in practice for the investigation of the mechanism of protein structural changes, though NMR is applicable only for small-sized proteins. However, x-ray analysis is not so suitable for analysis of their intermediate states. Thus, the author paid attention to the time-division type Laue method for the study of hemoglobin (Hb). Laser-flash induces to release carbonmonooxide (CO) from carboxyhemoglobin (Hb(CO) 4 ). Therefore, if an appropriate length of x-ray pulse (∼100 picosec) is available, the processes in the period from cleavage of the bond between a ligand (O 2 , CO or NO) and Hb to recombination of them might be monitored. Using DNA recombination and chemical modification techniques, recombinant Hb, of which T structure is stable was produced. An investigation on the conditions which allow to release CO from the Hb is undertaken using a single crystal of this Hb. The experimental systems applicable to time-division type Laue method are some protein molecules participating in chemical reactions inducible by light absorption, the electron-transfer system excited by light and so on. (M.N.)

  8. In-situ characterization of highly reversible phase transformation by synchrotron X-ray Laue microdiffraction

    International Nuclear Information System (INIS)

    Chen, Xian; Tamura, Nobumichi; MacDowell, Alastair; James, Richard D.

    2016-01-01

    The alloy Cu_2_5Au_3_0Zn_4_5 undergoes a huge first-order phase transformation (6% strain) and shows a high reversibility under thermal cycling and an unusual martensitc microstructure in sharp contrast to its nearby compositions. This alloy was discovered by systematically tuning the composition so that its lattice parameters satisfy the cofactor conditions (i.e., the kinematic conditions of compatibility between phases). It was conjectured that satisfaction of these conditions is responsible for the enhanced reversibility as well as the observed unusual fluid-like microstructure during transformation, but so far, there has been no direct evidence confirming that these observed microstructures are those predicted by the cofactor conditions. To verify this hypothesis, we use synchrotron X-ray Laue microdiffraction to measure the orientations and structural parameters of variants and phases near the austenite/martensite interface. The areas consisting of both austenite and multi-variants of martensite are scanned by microLaue diffraction. The cofactor conditions have been examined from the kinematic relation of lattice vectors across the interface. The continuity condition of the interface is precisely verified from the correspondent lattice vectors between two phases.

  9. Laue diffraction: The key to neutron crystallography from submillimetric-volume single crystals

    Science.gov (United States)

    Lemée-Cailleau, M.-H.; McIntyre, G. J.; Wilkinson, C.

    2005-12-01

    For several decades, chemists and physicists have been fascinated by molecular compounds rich in delocalized electrons. In the solid state these compounds may offer a very rich fan of properties: optical, conduction and dielectric, magneticldots Each state is the result of a delicate balance amongst intra- and/or intermolecular interactions which can be controlled, not just by direct chemical substitution, but also by external parameters such as temperature, pressure, continuous electric or magnetic fields, or by light. The recent evolution of this field of science towards more and more sophisticated materials makes also more and more difficult their crystal growth. While neutron scattering is an extremely powerful technique to get precise structural information, it is also often disregarded in this field because usually large single crystals are required. With the recent renaissance of Laue techniques using the very intense flux provided by the reactor of the Institut Laue-Langevin (ILL), accurate structural and/or magnetic information can be now extracted routinely from molecular crystals of volume 0.1 mm3 or smaller, with easy possibilities of high pressure (up to 3 GPa) down to 0.2 K. A general survey of these new possibilities is illustrated by an example taken from the field of low-dimensional organic complexes.

  10. Laue optics for nuclear astrophysics: New detector requirements for focused gamma-ray beams

    Energy Technology Data Exchange (ETDEWEB)

    Barriere, N. [INAF - IASF Roma, via Fosso del Cavaliere 100, 00133 Roma (Italy)], E-mail: nicolas.barriere@iasf-roma.inaf.it; Ballmoos, P. von [CESR - UMR 5187, 9 Av. du Colonel Roche, 31028 Toulouse (France); Abrosimov, N.V. [IKZ, Max Born-Str. 2, D-12489 Berlin (Germany); Bastie, P. [LSP UMR 5588, 140 Av. de la physique, 38402 Saint Martin d' Heres (France); Camus, T. [CESR - UMR 5187, 9 Av. du Colonel Roche, 31028 Toulouse (France); Courtois, P.; Jentschel, M. [ILL, 6 rue Jules Horowitz, 38042 Grenoble (France); Knoedlseder, J. [CESR - UMR 5187, 9 Av. du Colonel Roche, 31028 Toulouse (France); Natalucci, L. [INAF - IASF Roma, via Fosso del Cavaliere 100, 00133 Roma (Italy); Roudil, G.; Rousselle, J. [CESR - UMR 5187, 9 Av. du Colonel Roche, 31028 Toulouse (France); Wunderer, C.B. [SSL, University of California at Berkeley, CA 94708 (United States); Kurlov, V.N. [Institute of Solid State Physics of Russian Academy of Sciences, 142432 Chernogolovka (Russian Federation)

    2009-10-21

    Nuclear astrophysics presents an extraordinary scientific potential for the study of the most powerful sources and the most violent events in the Universe. But in order to take full advantage of this potential, telescopes should be at least an order of magnitude more sensitive than present technologies. Today, Laue lenses have demonstrated their capability of focusing gamma-rays in the 100 keV-1 MeV domain, enabling the possibility of building a new generation of instruments for which sensitive area is decoupled from collecting area. Thus we have now the opportunity of dramatically increase the signal/background ratio and hence improve significantly the sensitivity. With a lens, the best detector is no longer the largest possible within a mission envelope. The point spread function of a Laue lens measures a few centimeters in diameter, but the field of view is limited by the detector size. Requirements for a focal plane instrument are presented in the context of the Gamma-Ray Imager mission (proposed to European Space Agency, ESA in the framework of the first Cosmic Vision AO): a 15-20 cm a side finely pixellated detector capable of Compton events reconstruction seems to be optimal, giving polarization and background rejection capabilities and 30 arcsec of angular resolution within a field of view of 5 arc min.

  11. A study on structural changes in protein by time-division type Laue method

    Energy Technology Data Exchange (ETDEWEB)

    Morimoto, Hideki [Osaka Univ., Toyonaka (Japan). Faculty of Engineering Science

    1995-11-01

    In order to know the physiological roles of proteins, it is important to investigate the intermediate states of their structural changes. The sizes of proteins are generally several tens angstrom(A). Considering the resolution, only x-ray crystal analysis can be used in practice for the investigation of the mechanism of protein structural changes, though NMR is applicable only for small-sized proteins. However, x-ray analysis is not so suitable for analysis of their intermediate states. Thus, the author paid attention to the time-division type Laue method for the study of hemoglobin (Hb). Laser-flash induces to release carbonmonooxide (CO) from carboxyhemoglobin (Hb(CO){sub 4}). Therefore, if an appropriate length of x-ray pulse ({approx}100 picosec) is available, the processes in the period from cleavage of the bond between a ligand (O{sub 2}, CO or NO) and Hb to recombination of them might be monitored. Using DNA recombination and chemical modification techniques, recombinant Hb, of which T structure is stable was produced. An investigation on the conditions which allow to release CO from the Hb is undertaken using a single crystal of this Hb. The experimental systems applicable to time-division type Laue method are some protein molecules participating in chemical reactions inducible by light absorption, the electron-transfer system excited by light and so on. (M.N.)

  12. Study of imperfect natural diamonds with the application of the X-ray synchrotron radiation (the 'Laue-SR' method)

    International Nuclear Information System (INIS)

    Rylov, G.M.; Yefimova, E.S.; Sobolev, N.V.; Kulipanov, G.N.; Kondratyev, V.I.; Tolochko, B.P.; Sharafutdinov, M.R.

    2001-01-01

    The 'Laue-SR' method has been realised for fast gathering experimental data in the study of imperfect natural and synthesised diamonds which are hard to investigate with the conventional X-ray methods. Time to obtain a diffraction pattern with the use of the polychromatic SR is shorter by several orders; the resolution of the image of substructure defects of a crystal lattice (as compared to the conventional Laue method) is improved by an order and does not vanish even at large disorientation or other non-coherent disturbances of the crystal lattice. The 'Laue-SR' method is especially appropriate for the study of intact, sufficiently large diamond crystals (up to 5 mm), since the diamond has a small coefficient of the X-ray absorption and is practically transparent in the operational range of the SR waves, λ=0.5-1.5 A. This method was shown to be applied successfully for an accelerated study of a large bulk of imperfect natural diamond crystals without any preliminary preparation and without their destruction, which enlarges the information output in the study and, besides that, increases significantly the efficiency of the work. X-ray 'Laue-SR' topograms of imperfect diamonds with different types of distortions of the crystal lattice by natural processes during the formation of the diamonds and by epigenetic impacts are shown

  13. INTERFACE RESIDUAL STRESSES IN DENTAL ZIRCONIA USING LAUE MICRO-DIFFRACTION

    International Nuclear Information System (INIS)

    Bale, H. A.; Tamura, N.; Coelho, P.G.; Hanan, J. C.

    2009-01-01

    Due to their aesthetic value and high compressive strength, dentists have recently employed ceramics for restoration materials. Among the ceramic materials, zirconia provides high toughness and crack resistant characteristics. Residual stresses develop in processing due to factors including grain anisotropy and thermal coefficient mismatch. In the present study, polychromatic X-ray (Laue) micro-diffraction provided grain orientation and residual stresses on a clinically relevant zirconia model ceramic disk. A 0.5 mm x 0.024 mm region on zirconia was examined on a 500 nm scale for residual stresses using a focused poly-chromatic synchrotron X-ray beam. Large stresses ranging from - to + 1GPa were observed at some grains. On average, the method suggests a relatively small compressive stress at the surface between 47 and 75 MPa depending on direction

  14. X-ray Laue diffraction with allowance for second derivatives of amplitudes in dynamical diffraction equations

    International Nuclear Information System (INIS)

    Balyan, M.K.

    2014-01-01

    Asymmetrical Laue diffraction in a perfect crystal with a plane entrance surface is considered. The second derivatives of amplitudes in the direction, perpendicular to diffraction plane in the dynamical diffraction equations are taken into account. Using the corresponding Green function a general form for the amplitude of diffracted wave in the crystal is derived. The sizes of the source in both directions as well as the source of crystal distance and non-monochromaticity of the radiation incident on the crystal are taken into account. On the basis of obtained expression the coherent properties of the field depending on the sizes of the source and on the width of the spectrum of the incident radiation are analyzed. Taking into account the second derivatives of amplitudes with respect to the direction, perpendicular to the diffraction plane, the time dependent propagation equations for an X-ray pulse in a perfect crystal are given

  15. The new powder diffractometer D1B of the Institut Laue Langevin

    Science.gov (United States)

    Puente Orench, I.; Clergeau, J. F.; Martínez, S.; Olmos, M.; Fabelo, O.; Campo, J.

    2014-11-01

    D1B is a medium resolution high flux powder diffractometer located at the Institut Laue Langevin, ILL. D1B a suitable instrument for studying a large variety of polycrystalline materials. D1B runs since 1998 as a CRG (collaborating research group) instrument, being exploited by the CNRS (Centre National de la Recherche Scientifique, France) and CSIC (Consejo Superior de Investigaciones Cientificas, Spain). In 2008 the Spanish CRG started an updating program which included a new detector and a radial oscillating collimator (ROC). The detector, which has a sensitive height of 100mm, covers an angular range of 128°. Its 1280 gold wires provide a neutron detection point every 0.1°. The ROC is made of 198 gadolinium- based absorbing collimation blades, regular placed every 0.67°. Here the present characteristics of D1B are reviewed and the different experimental performances will be presented.

  16. Preliminary study of a phase transformation in insulin crystals using synchrotron-radiation Laue diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Reynolds, C D; Stowell, B; Joshi, K K; Harding, M M; Maginn, S J; Dodson, G G

    1988-10-01

    Synchrotron-radiation Laue diffraction photographs have been recorded showing the transformation of single 4Zn insulin crystals (a=80.7 (1), c=37.6 (1) A, space group R3) to 2Zn insulin (a=82.5 (1), c=34.0 (1) A, space group R3). The transformation was brought about by changing the mother liquor in the capillary in which the crystal was mounted. Photographs were taken at 10 min intervals (exposure time 3 s) from 0.5 h after mounting. They showed initially a well ordered 4Zn insulin crystal (d/sub min/ ca 2.3 A), then a poorly ordered, sometimes multiple, crystal, and finally a 2Zn insulin crystal, about as well ordered as the initial crystal.

  17. Analysis of strain error sources in micro-beam Laue diffraction

    International Nuclear Information System (INIS)

    Hofmann, Felix; Eve, Sophie; Belnoue, Jonathan; Micha, Jean-Sébastien; Korsunsky, Alexander M.

    2011-01-01

    Micro-beam Laue diffraction is an experimental method that allows the measurement of local lattice orientation and elastic strain within individual grains of engineering alloys, ceramics, and other polycrystalline materials. Unlike other analytical techniques, e.g. based on electron microscopy, it is not limited to surface characterisation or thin sections, but rather allows non-destructive measurements in the material bulk. This is of particular importance for in situ loading experiments where the mechanical response of a material volume (rather than just surface) is studied and it is vital that no perturbation/disturbance is introduced by the measurement technique. Whilst the technique allows lattice orientation to be determined to a high level of precision, accurate measurement of elastic strains and estimating the errors involved is a significant challenge. We propose a simulation-based approach to assess the elastic strain errors that arise from geometrical perturbations of the experimental setup. Using an empirical combination rule, the contributions of different geometrical uncertainties to the overall experimental strain error are estimated. This approach was applied to the micro-beam Laue diffraction setup at beamline BM32 at the European Synchrotron Radiation Facility (ESRF). Using a highly perfect germanium single crystal, the mechanical stability of the instrument was determined and hence the expected strain errors predicted. Comparison with the actual strain errors found in a silicon four-point beam bending test showed good agreement. The simulation-based error analysis approach makes it possible to understand the origins of the experimental strain errors and thus allows a directed improvement of the experimental geometry to maximise the benefit in terms of strain accuracy.

  18. Dose rate effect on micronuclei induction in human blood lymphocytes exposed to single pulse and multiple pulses of electrons.

    Science.gov (United States)

    Acharya, Santhosh; Bhat, N N; Joseph, Praveen; Sanjeev, Ganesh; Sreedevi, B; Narayana, Y

    2011-05-01

    The effects of single pulses and multiple pulses of 7 MV electrons on micronuclei (MN) induction in cytokinesis-blocked human peripheral blood lymphocytes (PBLs) were investigated over a wide range of dose rates per pulse (instantaneous dose rate). PBLs were exposed to graded doses of 2, 3, 4, 6, and 8 Gy of single electron pulses of varying pulse widths at different dose rates per pulse, ranging from 1 × 10(6) Gy s(-1) to 3.2 × 10(8) Gy s(-1). Different dose rates per pulse were achieved by changing the dose per electron pulse by adjusting the beam current and pulse width. MN yields per unit absorbed dose after irradiation with single electron pulses were compared with those of multiple pulses of electrons. A significant decrease in the MN yield with increasing dose rates per pulse was observed, when dose was delivered by a single electron pulse. However, no reduction in the MN yield was observed when dose was delivered by multiple pulses of electrons. The decrease in the yield at high dose rates per pulse suggests possible radical recombination, which leads to decreased biological damage. Cellular response to the presence of very large numbers of chromosomal breaks may also alter the damage.

  19. Saturated multikilovolt x-ray amplification with Xe clusters: single-pulse observation of Xe(L) spectral hole burning

    International Nuclear Information System (INIS)

    Borisov, Alex B; Davis, Jack; Song, Xiangyang; Koshman, Yevgeniya; Dai Yang; Boyer, Keith; Rhodes, Charles K

    2003-01-01

    Single-pulse measurements of spectral hole burning of Xe(L) 3d → 2p hollow atom transition arrays observed from a self-trapped plasma channel provide new information on the dynamics of saturated amplification in the λ ∼ 2.8-2.9 A region. The spectral hole burning on transitions in the Xe 34+ and Xe 35+ arrays reaches full suppression of the spontaneous emission and presents a corresponding width Δ h-bar ω x ∼ = 60 eV, a value adequate for efficient amplification of multikilovolt x-ray pulses down to a limiting length τ x ∼ 30 as. The depth of the suppression at 2.86 A indicates that the gain-to-loss ratio is ≥10. An independent determination of the x-ray pulse energy from damage produced on the surface of a Ti foil in the far field of the source gives a pulse energy of 20-30 μJ, a range that correlates well with the observation of the spectral hole burning and indicates an overall extraction efficiency of ∼10%. (letter to the editor)

  20. Shifts in the metabolic function of a benthic estuarine microbial community following a single pulse exposure to silver nanoparticles

    International Nuclear Information System (INIS)

    Echavarri-Bravo, Virginia; Paterson, Lynn; Aspray, Thomas J.; Porter, Joanne S.; Winson, Michael K.; Thornton, Barry; Hartl, Mark G.J.

    2015-01-01

    The increasing use of silver nanoparticles (AgNPs) as a biocidal agent and their potential accumulation in sediments may threaten non-target natural environmental bacterial communities. In this study a microcosm approach was established to investigate the effects of well characterized OECD AgNPs (NM-300) on the function of the bacterial community inhabiting marine estuarine sediments (salinity 31‰). The results showed that a single pulse of NM-300 AgNPs (1 mg L −1 ) that led to sediment concentrations below 6 mg Ag kg −1 dry weight inhibited the bacterial utilization of environmentally relevant carbon substrates. As a result, the functional diversity changed, but recovered after 120 h under the experimental conditions. This microcosm study suggests that AgNPs under environmentally relevant experimental conditions can negatively affect bacterial function and provides an insight into the understanding of the bacterial community response and resilience to AgNPs exposure, important for informing relevant regulatory measures. - Highlights: • AgNPs affected the bacterial community function in estuarine marine sediments. • AgNPs inhibited the bacterial utilization of environmentally relevant substrates. • Heterotrophic bacterial groups showed resilience to AgNPs after 120 h exposure. • AgNPs did not affect the bacterial community structure in sediments. - AgNPs inhibited the bacterial utilization of environmentally relevant substrates and caused temporary shifts in the bacterial functional diversity in marine estuarine sediments

  1. Long-duration nano-second single pulse lasers for observation of spectra from bulk liquids at high hydrostatic pressures

    International Nuclear Information System (INIS)

    Thornton, Blair; Sakka, Tetsuo; Masamura, Tatsuya; Tamura, Ayaka; Takahashi, Tomoko; Matsumoto, Ayumu

    2014-01-01

    The influence of laser pulse duration on the spectral emissions observed from bulk ionic solutions has been investigated for hydrostatic pressures between 0.1 and 30 MPa. Transient pressure, shadowgraph imaging and spectroscopic measurements were performed for single pulses of duration 20 and 150 ns. The transient pressure measurements show that for hydrostatic pressures up to 30 MPa, propagation of the high-pressure shockwave generated by the focused laser causes the local pressure to reduce below ambient levels during the time frame that spectroscopic measurements can be made. The pressure impulse and subsequent reduction in pressure are larger, with the latter lasting longer for the 150 ns pulse compared to a 20 ns pulse of the same energy. The 150 ns pulse generates larger cavities with significant enhancement of the spectral emissions observed compared to the 20 ns duration pulse for pressures up to 30 MPa. The results demonstrate that laser-induced breakdown using a long ns duration pulse offers an advantage over conventional, short ns duration pulses for the analysis of bulk ionic solutions at hydrostatic pressures between 0.1 and 30 MPa. - Highlights: • Long-ns-duration laser pulses enhance the spectra observed from bulk solutions. • Laser-induced shockwaves momentarily reduce pressures to below ambient levels. • 150 ns pulses generate larger cavities than 20 ns pulses of the same energy. • Hydrostatic pressures < 30 MPa have no significant effect on the observed spectra

  2. Development of a pump-probe facility with sub-picosecond time resolution combining a high-power ultraviolet regenerative FEL amplifier and a soft X-ray SASE FEL

    International Nuclear Information System (INIS)

    Faatz, B.; Fateev, A.A.; Feldhaus, J.; Krzywinski, J.; Pflueger, J.; Rossbach, J.; Saldin, E.L.; Schneidmiller, E.A.; Yurkov, M.V.

    2001-01-01

    This paper presents the conceptual design of a high power radiation source with laser-like characteristics in the ultraviolet spectral range at the TESLA Test Facility (TTF). The concept is based on the generation of radiation in a regenerative FEL amplifier (RAFEL). The RAFEL described in this paper covers a wavelength range of 200-400 nm and provides 200 fs pulses with 2 mJ of optical energy per pulse. The linac operates at 1% duty factor and the average output radiation power exceeds 100 W. The RAFEL will be driven by the spent electron beam leaving the soft X-ray FEL, thus providing minimal interference between these two devices. The RAFEL output radiation has the same time structure as the X-ray FEL and the UV pulses are naturally synchronized with the soft X-ray pulses from the TTF FEL. Therefore, it should be possible to achieve synchronization close to the duration of the radiation pulses (200 fs) for pump-probe techniques using either an UV pulse as a pump and soft X-ray pulse as a probe, or vice versa

  3. Sensitive detection of chlorine in iron oxide by single pulse and dual pulse laser-induced breakdown spectroscopy

    Science.gov (United States)

    Pedarnig, J. D.; Haslinger, M. J.; Bodea, M. A.; Huber, N.; Wolfmeir, H.; Heitz, J.

    2014-11-01

    The halogen chlorine is hard to detect in laser-induced breakdown spectroscopy (LIBS) mainly due to its high excited state energies of 9.2 and 10.4 eV for the most intense emission lines at 134.72 nm and 837.59 nm, respectively. We report on sensitive detection of Cl in industrial iron oxide Fe2O3 powder by single-pulse (SP) and dual-pulse (DP) LIBS measurements in the near infrared range in air. In compacted powder measured by SP excitation (Nd:YAG laser, 532 nm) Cl was detected with limit of detection LOD = 440 ppm and limit of quantitation LOQ = 720 ppm. Orthogonal DP LIBS was studied on pressed Fe2O3 pellets and Fe3O4 ceramics. The transmission of laser-induced plasma for orthogonal Nd:YAG 1064 nm and ArF 193 nm laser pulses showed a significant dependence on interpulse delay time (ipd) and laser wavelength (λL). The UV pulses (λL = 193 nm) were moderately absorbed in the plasma and the Cl I emission line intensity was enhanced while IR pulses (λL = 1064 nm) were not absorbed and Cl signals were not enhanced at ipd = 3 μs. The UV laser enhancement of Cl signals is attributed to the much higher signal/background ratio for orthogonal DP excitation compared to SP excitation and to the increased plasma temperature and electron number density. This enabled measurement at a very short delay time of td ≥ 0.1 μs with respect to the re-excitation pulse and detection of the very rapidly decaying Cl emission with higher efficiency.

  4. Simulation investigation of thermal phase transformation and residual stress in single pulse EDM of Ti-6Al-4V

    Science.gov (United States)

    Tang, Jiajing; Yang, Xiaodong

    2018-04-01

    The thermal phase transformation and residual stress are ineluctable in the electrical discharge machining (EDM) process, and they will greatly affect the working performances of the machined surface. This paper presents a simulation study on the thermal phase transformation and residual stress in single-pulse EDM of Ti-6Al-4V, which is the most popular titanium alloy in fields such as aircraft engine and some other leading industries. A multi-physics model including thermal, hydraulic, metallography and structural mechanics was developed. Based on the proposed model, the thickness and metallographic structure of the recast layer and heat affected layer (HAZ) were investigated. The distribution and characteristics of residual stress around the discharge crater were obtained. The recast layer and HAZ at the center of crater are found to be the thinnest, and their thicknesses gradually increase approaching the periphery of the crater. The recast layer undergoes a complete α‧ (martensitic) transformation, while the HAZ is mainly composed by the α  +  β  +  α‧ three-phase microstructure. Along the depth direction of crater, the Von Mises stress increases first and then decreases, reaching its maximal value near the interface of recast layer and HAZ. In the recast layer, both compressive stress component and tensile stress component are observed. ANOVA results showed that the influence of discharge current on maximal tensile stress is more significant than that of pulse duration, while the pulse duration has more significant influence on average thickness of the recast layer and the depth location of the maximal tensile stress. The works conducted in this study will help to evaluate the quality and integrity of EDMed surface, especially when the non-destructive testing is difficult to achieve.

  5. Laue diffraction as a tool in dynamic studies: Hydrolysis of a transiently stable intermediate in catalysis by trypsin

    Energy Technology Data Exchange (ETDEWEB)

    Singer, P.T.; Berman, L.E.; Cai, Z.; Mangel, W.F.; Jones, K.W.; Sweet, R.M. (Brookhaven National Lab., Upton, NY (United States)); Carty, R.P. (State Univ. of New York, Brooklyn, NY (United States). Dept. of Biochemistry); Schlichting, I. (Brandeis Univ., Waltham, MA (United States). Rosenstiel Basic Medical Science Center); Stock, A. (Center for Advanced Biotechnology and Medicine, Piscataway, NJ (Un

    1992-01-01

    A transiently stable intermediate in trypsin catalysis, guanidinobenzyol-Ser-195 trypsin, can be trapped and then released by control of the pH in crystals of the enzyme. This effect has been investigated by static and dynamic white-beam Laue crystallography. Comparison of structures determined before and immediately after a pH jump reveals the nature of concerted changes that accompany activation of the enzyme. Careful analysis of the results of several structure determinations gives information about the reliability of Laue results in general. A study of multiple exposures taken under differing conditions of beam intensity, crystal quality, and temperature revealed information about ways to control damage of specimens by the x-ray beam.

  6. Laue diffraction as a tool in dynamic studies: Hydrolysis of a transiently stable intermediate in catalysis by trypsin

    Energy Technology Data Exchange (ETDEWEB)

    Singer, P.T.; Berman, L.E.; Cai, Z.; Mangel, W.F.; Jones, K.W.; Sweet, R.M. [Brookhaven National Lab., Upton, NY (United States); Carty, R.P. [State Univ. of New York, Brooklyn, NY (United States). Dept. of Biochemistry; Schlichting, I. [Brandeis Univ., Waltham, MA (United States). Rosenstiel Basic Medical Science Center; Stock, A. [Center for Advanced Biotechnology and Medicine, Piscataway, NJ (United States); Smalas, A. [Univ. of Tromso (Norway). Inst. of Mathematics and Physical Science

    1992-11-01

    A transiently stable intermediate in trypsin catalysis, guanidinobenzyol-Ser-195 trypsin, can be trapped and then released by control of the pH in crystals of the enzyme. This effect has been investigated by static and dynamic white-beam Laue crystallography. Comparison of structures determined before and immediately after a pH jump reveals the nature of concerted changes that accompany activation of the enzyme. Careful analysis of the results of several structure determinations gives information about the reliability of Laue results in general. A study of multiple exposures taken under differing conditions of beam intensity, crystal quality, and temperature revealed information about ways to control damage of specimens by the x-ray beam.

  7. Laue diffraction as a tool in dynamic studies: Hydrolysis of a transiently stable intermediate in catalysis by trypsin

    International Nuclear Information System (INIS)

    Singer, P.T.; Berman, L.E.; Cai, Z.; Mangel, W.F.; Jones, K.W.; Sweet, R.M.; Carty, R.P.; Smalas, A.

    1992-01-01

    A transiently stable intermediate in trypsin catalysis, guanidinobenzyol-Ser-195 trypsin, can be trapped and then released by control of the pH in crystals of the enzyme. This effect has been investigated by static and dynamic white-beam Laue crystallography. Comparison of structures determined before and immediately after a pH jump reveals the nature of concerted changes that accompany activation of the enzyme. Careful analysis of the results of several structure determinations gives information about the reliability of Laue results in general. A study of multiple exposures taken under differing conditions of beam intensity, crystal quality, and temperature revealed information about ways to control damage of specimens by the x-ray beam

  8. Characterizing Grain-Oriented Silicon Steel Sheet Using Automated High-Resolution Laue X-ray Diffraction

    Science.gov (United States)

    Lynch, Peter; Barnett, Matthew; Stevenson, Andrew; Hutchinson, Bevis

    2017-11-01

    Controlling texture in grain-oriented (GO) silicon steel sheet is critical for optimization of its magnetization performance. A new automated laboratory system, based on X-ray Laue diffraction, is introduced as a rapid method for large scale grain orientation mapping and texture measurement in these materials. Wide area grain orientation maps are demonstrated for both macroetched and coated GO steel sheets. The large secondary grains contain uniform lattice rotations, the origins of which are discussed.

  9. Laue lens for radiotherapy applications through a focused hard x-ray beam: a feasibility study on requirements and tolerances

    Science.gov (United States)

    Camattari, Riccardo

    2017-09-01

    Focusing a hard x-ray beam would represent an innovative technique for tumour treatment, since such a beam may deliver a dose to a tumour located at a given depth under the skin, sparing the surrounding healthy cells. A detailed study of a focusing system for hard x-ray aimed at radiotherapy is presented here. Such a focusing system, named Laue lens, exploits x-ray diffraction and consists of a series of crystals disposed as concentric rings capable of concentrating a flux of x-rays towards a focusing point. A feasibility study regarding the positioning tolerances of the crystalline optical elements has been carried out. It is shown that a Laue lens can effectively be used in the context of radiotherapy for tumour treatments provided that the mounting errors are below certain values, which are reachable in the modern micromechanics. An extended survey based on an analytical approach and on simulations is presented for precisely estimating all the contributions of each mounting error, analysing their effect on the focal spot of the Laue lens. Finally, a simulation for evaluating the released dose in a water phantom is shown.

  10. Study of imperfect natural diamonds with the application of the X-ray synchrotron radiation (the 'Laue-SR' method)

    CERN Document Server

    Rylov, G M; Sobolev, N V; Kulipanov, G N; Kondratyev, V I; Tolochko, B P; Sharafutdinov, M R

    2001-01-01

    The 'Laue-SR' method has been realised for fast gathering experimental data in the study of imperfect natural and synthesised diamonds which are hard to investigate with the conventional X-ray methods. Time to obtain a diffraction pattern with the use of the polychromatic SR is shorter by several orders; the resolution of the image of substructure defects of a crystal lattice (as compared to the conventional Laue method) is improved by an order and does not vanish even at large disorientation or other non-coherent disturbances of the crystal lattice. The 'Laue-SR' method is especially appropriate for the study of intact, sufficiently large diamond crystals (up to 5 mm), since the diamond has a small coefficient of the X-ray absorption and is practically transparent in the operational range of the SR waves, lambda=0.5-1.5 A. This method was shown to be applied successfully for an accelerated study of a large bulk of imperfect natural diamond crystals without any preliminary preparation and without their destru...

  11. Energy resolution of the CdTe-XPAD detector:calibration and potential for Laue diffractionmeasurements on protein crystals

    Energy Technology Data Exchange (ETDEWEB)

    Medjoubi K.; Idir M.; Thompson, A.; Berar, J-F.; Clemens, J-C.; Delpierre, P.; Da Silva, P.; Dinkespiler, B.; Itie, J-P.; Legrand, P.; Menneglier, C.; Mercere, P.; Picca, F.; Samama J-P.

    2012-02-02

    The XPAD3S-CdTe, a CdTe photon-counting pixel array detector, has been used to measure the energy and the intensity of the white-beam diffraction from a lysozyme crystal. A method was developed to calibrate the detector in terms of energy, allowing incident photon energy measurement to high resolution (approximately 140 eV), opening up new possibilities in energy-resolved X-ray diffraction. In order to demonstrate this, Laue diffraction experiments were performed on the bending-magnet beamline METROLOGIE at Synchrotron SOLEIL. The X-ray energy spectra of diffracted spots were deduced from the indexed Laue patterns collected with an imaging-plate detector and then measured with both the XPAD3S-CdTe and the XPAD3S-Si, a silicon photon-counting pixel array detector. The predicted and measured energy of selected diffraction spots are in good agreement, demonstrating the reliability of the calibration method. These results open up the way to direct unit-cell parameter determination and the measurement of high-quality Laue data even at low resolution. Based on the success of these measurements, potential applications in X-ray diffraction opened up by this type of technology are discussed.

  12. Presentation of the High-Flux Reactor of the Institut Laue-Langevin

    International Nuclear Information System (INIS)

    Guyon, H.

    2006-01-01

    Full text of publication follows: The High-Flux Reactor (HFR) of the Institut Laue-Langevin is the world's most intense source of neutrons for fundamental research. Thanks to its extremely compact core, which is made up of a single fuel element, the HFR is capable of producing a neutron flux of up to 1.5.10 15 n.cm -2 .s -1 with a moderate power output of 58 MW. Its heavy water reflector thermalizes these neutrons, giving them a wave length of the order of one angstrom. They then become an excellent tool for exploring the atomic structure of matter. In order to provide a full neutron spectrum, the reactor is also equipped with a hot source (a block of graphite heated to 2000 deg. C) and two cold sources (a volume of liquid deuterium at 25 K). All the reactor's components can be replaced and adapted in order to keep pace with both changing scientific needs and changing safety requirements. For example, in 1992 the reactor block was replaced, a second cold source was installed in 1985, and the beam tubes are replaced at regularly intervals and are also occasionally modified. In the same way, the reactor's civil engineering structures are currently being reinforced in order to comply with the reassessment of the reference earthquake spectra. Finally, the Institut Laue-Langevin's reactor is equipped with three solid containment barriers: - the fuel cladding: during the 35 years the reactor has been in operation, a cladding failure has never been detected; - the leak-tight primary cooling system: this is partly submerged in a pool which provides radiological shielding; - the double-wall containment: an overpressure of air is maintained between the inner reinforced concrete wall and the outer metal wall. The High-Flux Reactor is therefore all set to provide the scientific community with top quality service for the next 20 years to come, on a site which: - is home to the brightest synchrotron in the world (ESRF); - benefits from the microbiology expertise of the EMBL

  13. Presentation of the High-Flux Reactor of the Institut Laue-Langevin

    Energy Technology Data Exchange (ETDEWEB)

    Guyon, H. [Institut Laue-Langevin, Grenoble (France)

    2006-07-01

    Full text of publication follows: The High-Flux Reactor (HFR) of the Institut Laue-Langevin is the world's most intense source of neutrons for fundamental research. Thanks to its extremely compact core, which is made up of a single fuel element, the HFR is capable of producing a neutron flux of up to 1.5.10{sup 15} n.cm{sup -2}.s{sup -1} with a moderate power output of 58 MW. Its heavy water reflector thermalizes these neutrons, giving them a wave length of the order of one angstrom. They then become an excellent tool for exploring the atomic structure of matter. In order to provide a full neutron spectrum, the reactor is also equipped with a hot source (a block of graphite heated to 2000 deg. C) and two cold sources (a volume of liquid deuterium at 25 K). All the reactor's components can be replaced and adapted in order to keep pace with both changing scientific needs and changing safety requirements. For example, in 1992 the reactor block was replaced, a second cold source was installed in 1985, and the beam tubes are replaced at regularly intervals and are also occasionally modified. In the same way, the reactor's civil engineering structures are currently being reinforced in order to comply with the reassessment of the reference earthquake spectra. Finally, the Institut Laue-Langevin's reactor is equipped with three solid containment barriers: - the fuel cladding: during the 35 years the reactor has been in operation, a cladding failure has never been detected; - the leak-tight primary cooling system: this is partly submerged in a pool which provides radiological shielding; - the double-wall containment: an overpressure of air is maintained between the inner reinforced concrete wall and the outer metal wall. The High-Flux Reactor is therefore all set to provide the scientific community with top quality service for the next 20 years to come, on a site which: - is home to the brightest synchrotron in the world (ESRF); - benefits from the

  14. A focal plane detector design for a wide-band Laue-lens telescope

    DEFF Research Database (Denmark)

    Caroli, E.; Auricchio, N.; Amati, L.

    2005-01-01

    , and the detection of nuclear and annihilation lines. Recently the development of high energy Laue lenses with broad energy bandpasses from 60 to 600 keV have been proposed for a Hard X ray focusing Telescope (HAXTEL) in order to study the X-ray continuum of celestial sources. The required focal plane detector...... should have high detection efficiency over the entire operative range, a spatial resolution of about 1 mm, an energy resolution of a few keV at 500 keV and a sensitivity to linear polarization. We describe a possible configuration of the focal plane detector based on several CdTe/CZT pixelated layers......The energy range above 60 keV is important for the study of many open problems in high energy astrophysics such as the role of Inverse Compton with respect to synchrotron or thermal processes in GRBs, non thermal mechanisms in SNR, the study of the high energy cut-offs in AGN spectra...

  15. Manufacturing of advanced bent crystals for Laue Optics for Gamma ObservationS (LOGOS)

    International Nuclear Information System (INIS)

    Mazzolari, Andrea; Camattari, Riccardo; Bellucci, Valerio; Paternò, Gianfranco; Scian, Carlo; Mattei, Giovanni; Guidi, Vincenzo

    2015-01-01

    X- and γ-ray detection is currently a hot topic for a wide scientific community, spanning from astrophysics to nuclear medicine. However, lack of optics capable of focusing photons of energies in the energy range 0.1–1 MeV leaves the photon detection to a direct-view approach, resulting in a limited efficiency and resolution. The main scope of the INFN-LOGOS project is the development of technologies that enable manufacturing highly performing optical elements to be employed in the realization of hard X-ray lenses. Such lenses, typically named Laue lenses, consist of an ensemble of crystals disposed in concentric rings in order to diffract the incident radiation towards the focus of the lens, where a detector is placed. In particular, the INFN-LOGOS project aims at the realization of intrinsically bent silicon and germanium crystals exploiting the quasi-mosaic effect for focusing hard X-rays. Crystal manufacturing relies on a proper revisitation of techniques typically employed in silicon micromachining, such as thin film deposition and patterning or ion implantation

  16. Institut Laue Langevin. Complementary safety evaluation in the light of the Fukushima accident

    International Nuclear Information System (INIS)

    2011-01-01

    This report proposes a complementary safety evaluation of Laue Langevin Institute (ILL) in Grenoble, one of the French basic nuclear installations (BNI, in French INB) in the light of the Fukushima accident. This evaluation takes the following risks into account: risks of flooding, earthquake, loss of power supply and loss of cooling, in addition to operational management of accident situations. It presents some characteristics of the installation (location, operator, industrial environment, installation characteristics), reports a macroscopic safety study focused of installation structures, systems and components, evaluates the seismic risk (installation sizing, margin evaluation, reinforcement propositions, possible ground acceleration levels, reactivity, cooling and confinement control), evaluates the flooding risk (installation sizing, margin evaluation), briefly examines other extreme natural phenomena (extreme meteorological conditions related to flooding, earthquake with flooding). It analyzes the risk of a loss of power supply and of cooling (loss of external and internal electric sources, loss of the ultimate cooling system). It analyzes the management of severe accidents: core cooling management, confinement management after fuel damage, cooling management of irradiated fuel element in pool, cliff effect for these three types of accident. It discusses the conditions of the use of subcontractors. In conclusion, reinforcement and strengthening measures are proposed and discussed

  17. Multilayer Laue Lens: A Path Toward One Nanometer X-Ray Focusing

    International Nuclear Information System (INIS)

    Yan, H.; Stephenson, G.B.; Maser, J.; Yan, H.; Conley, R.; Kang, H.C.; Stephenson, G.B.; Kang, H.C.; Maser, J.; Conley, R.; Liu, Ch.; Macrander, A.T.

    2010-01-01

    The multilayer Laue lens (MLL) is a novel diffractive optic for hard X-ray nano focusing, which is fabricated by thin film deposition techniques and takes advantage of the dynamical diffraction effect to achieve a high numerical aperture and efficiency. It overcomes two difficulties encountered in diffractive optics fabrication for focusing hard X-rays: (1) small outmost zone width and (2) high aspect ratio. Here, we will give a review on types, modeling approaches, properties, fabrication, and characterization methods of MLL optics. We show that a full-wave dynamical diffraction theory has been developed to describe the dynamical diffraction property of the MLL and has been employed to design the optimal shapes for nano focusing. We also show a 16 nm line focus obtained by a partial MLL and several characterization methods. Experimental results show a good agreement with the theoretical calculations. With the continuing development of MLL optics, we believe that an MLL-based hard x-ray microscope with true nanometer resolution is on the horizon

  18. Manufacturing of advanced bent crystals for Laue Optics for Gamma ObservationS (LOGOS)

    Energy Technology Data Exchange (ETDEWEB)

    Mazzolari, Andrea, E-mail: mazzolari@fe.infn.it [Department of Physics and Earth Sciences, University of Ferrara, Via Saragat 1/c, 44122 Ferrara (Italy); INFN, Section of Ferrara (Italy); Camattari, Riccardo; Bellucci, Valerio; Paternò, Gianfranco [Department of Physics and Earth Sciences, University of Ferrara, Via Saragat 1/c, 44122 Ferrara (Italy); INFN, Section of Ferrara (Italy); Scian, Carlo; Mattei, Giovanni [University of Padova, Department of Physics and Astronomy Galileo Galilei (Italy); Guidi, Vincenzo [Department of Physics and Earth Sciences, University of Ferrara, Via Saragat 1/c, 44122 Ferrara (Italy); INFN, Section of Ferrara (Italy)

    2015-07-15

    X- and γ-ray detection is currently a hot topic for a wide scientific community, spanning from astrophysics to nuclear medicine. However, lack of optics capable of focusing photons of energies in the energy range 0.1–1 MeV leaves the photon detection to a direct-view approach, resulting in a limited efficiency and resolution. The main scope of the INFN-LOGOS project is the development of technologies that enable manufacturing highly performing optical elements to be employed in the realization of hard X-ray lenses. Such lenses, typically named Laue lenses, consist of an ensemble of crystals disposed in concentric rings in order to diffract the incident radiation towards the focus of the lens, where a detector is placed. In particular, the INFN-LOGOS project aims at the realization of intrinsically bent silicon and germanium crystals exploiting the quasi-mosaic effect for focusing hard X-rays. Crystal manufacturing relies on a proper revisitation of techniques typically employed in silicon micromachining, such as thin film deposition and patterning or ion implantation.

  19. SuperADAM: upgraded polarized neutron reflectometer at the Institut Laue-Langevin.

    Science.gov (United States)

    Devishvili, A; Zhernenkov, K; Dennison, A J C; Toperverg, B P; Wolff, M; Hjörvarsson, B; Zabel, H

    2013-02-01

    A new neutron reflectometer SuperADAM has recently been built and commissioned at the Institut Laue-Langevin, Grenoble, France. It replaces the previous neutron reflectometer ADAM. The new instrument uses a solid state polarizer/wavelength filter providing a highly polarized (up to 98.6%) monochromatic neutron flux of 8 × 10(4) n cm(-2) s(-1) with monochromatization Δλ∕λ = 0.7% and angular divergence Δα = 0.2 mrad. The instrument includes both single and position sensitive detectors. The position sensitive detector allows simultaneous measurement of specular reflection and off-specular scattering. Polarization analysis for both specular reflection and off-specular scattering is achieved using either mirror analyzers or a (3)He spin filter cell. High efficiency detectors, low background, and high flux provides a dynamic range of up to seven decades in reflectivity. Detailed specifications and the instrument capabilities are illustrated with examples of recently collected data in the fields of thin film magnetism and thin polymer films.

  20. Fast GPU-based spot extraction for energy-dispersive X-ray Laue diffraction

    International Nuclear Information System (INIS)

    Alghabi, F.; Schipper, U.; Kolb, A.; Send, S.; Abboud, A.; Pashniak, N.; Pietsch, U.

    2014-01-01

    This paper describes a novel method for fast online analysis of X-ray Laue spots taken by means of an energy-dispersive X-ray 2D detector. Current pnCCD detectors typically operate at some 100 Hz (up to a maximum of 400 Hz) and have a resolution of 384 × 384 pixels, future devices head for even higher pixel counts and frame rates. The proposed online data analysis is based on a computer utilizing multiple Graphics Processing Units (GPUs), which allow for fast and parallel data processing. Our multi-GPU based algorithm is compliant with the rules of stream-based data processing, for which GPUs are optimized. The paper's main contribution is therefore an alternative algorithm for the determination of spot positions and energies over the full sequence of pnCCD data frames. Furthermore, an improved background suppression algorithm is presented.The resulting system is able to process data at the maximum acquisition rate of 400 Hz. We present a detailed analysis of the spot positions and energies deduced from a prior (single-core) CPU-based and the novel GPU-based data processing, showing that the parallel computed results using the GPU implementation are at least of the same quality as prior CPU-based results. Furthermore, the GPU-based algorithm is able to speed up the data processing by a factor of 7 (in comparison to single-core CPU-based algorithm) which effectively makes the detector system more suitable for online data processing

  1. Development of a bent Laue beam-expanding double-crystal monochromator for biomedical X-ray imaging

    International Nuclear Information System (INIS)

    Martinson, Mercedes; Samadi, Nazanin; Belev, George; Bassey, Bassey; Lewis, Rob; Aulakh, Gurpreet; Chapman, Dean

    2014-01-01

    A bent Laue beam-expanding double-crystal monochromator was developed and tested at the Biomedical Imaging and Therapy beamline at the Canadian Light Source. The expander will reduce scanning time for micro-computed tomography and allow dynamic imaging that has not previously been possible at this beamline. The Biomedical Imaging and Therapy (BMIT) beamline at the Canadian Light Source has produced some excellent biological imaging data. However, the disadvantage of a small vertical beam limits its usability in some applications. Micro-computed tomography (micro-CT) imaging requires multiple scans to produce a full projection, and certain dynamic imaging experiments are not possible. A larger vertical beam is desirable. It was cost-prohibitive to build a longer beamline that would have produced a large vertical beam. Instead, it was proposed to develop a beam expander that would create a beam appearing to originate at a source much farther away. This was accomplished using a bent Laue double-crystal monochromator in a non-dispersive divergent geometry. The design and implementation of this beam expander is presented along with results from the micro-CT and dynamic imaging tests conducted with this beam. Flux (photons per unit area per unit time) has been measured and found to be comparable with the existing flat Bragg double-crystal monochromator in use at BMIT. This increase in overall photon count is due to the enhanced bandwidth of the bent Laue configuration. Whilst the expanded beam quality is suitable for dynamic imaging and micro-CT, further work is required to improve its phase and coherence properties

  2. Deep tissue optical imaging of upconverting nanoparticles enabled by exploiting higher intrinsic quantum yield through use of millisecond single pulse excitation with high peak power

    DEFF Research Database (Denmark)

    Liu, Haichun; Xu, Can T.; Dumlupinar, Gökhan

    2013-01-01

    We have accomplished deep tissue optical imaging of upconverting nanoparticles at 800 nm, using millisecond single pulse excitation with high peak power. This is achieved by carefully choosing the pulse parameters, derived from time-resolved rate-equation analysis, which result in higher intrinsic...... quantum yield that is utilized by upconverting nanoparticles for generating this near infrared upconversion emission. The pulsed excitation approach thus promises previously unreachable imaging depths and shorter data acquisition times compared with continuous wave excitation, while simultaneously keeping...... therapy and remote activation of biomolecules in deep tissues....

  3. Texture, residual strain, and plastic deformation around scratches in alloy 600 using synchrotron X-ray Laue micro-diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Suominen Fuller, M.L. [Surface Science Western, Room G-1, Western Science Centre, University of Western Ontario, London, Ontario, N6A 5B7 (Canada)], E-mail: mfuller@uwo.ca; Klassen, R.J. [Department of Mechanical and Materials Engineering, Room 3002 Spencer Engineering Building, University of Western Ontario, London, Ontario, N6A 5B9 (Canada); McIntyre, N.S. [Surface Science Western, Room G-1, Western Science Centre, University of Western Ontario, London, Ontario, N6A 5B7 (Canada); Gerson, A.R. [Applied Centre for Structural and Synchrotron Studies, Mawson Lakes Campus, University of South Australia, Adelaide, South Australia 5095 (Australia); Ramamurthy, S. [Surface Science Western, Room G-1, Western Science Centre, University of Western Ontario, London, Ontario, N6A 5B7 (Canada); King, P.J. [Babcock and Wilcox Canada, 581 Coronation Blvd., Cambridge, Ontario, N1R5V3 (Canada); Liu, W. [Advanced Photon Source, Argonne National Laboratory, 9700 S. Cass Avenue, Argonne, IL 60439 (United States)

    2008-03-15

    Deformation around two scratches in Alloy 600 (A600) was studied nondestructively using synchrotron Laue differential aperture X-ray microscopy. The orientation of grains and elastic strain distribution around the scratches were measured. A complex residual deviatoric elastic strain state was found to exist around the scratches. Heavy plastic deformation was observed up to a distance of 20 {mu}m from the scratches. In the region 20-30 {mu}m from the scratches the diffraction spots were heavily streaked and split indicating misoriented dislocation cell structures.

  4. Strength of shock-loaded single-crystal tantalum [100] determined using in situ broadband x-ray Laue diffraction.

    Science.gov (United States)

    Comley, A J; Maddox, B R; Rudd, R E; Prisbrey, S T; Hawreliak, J A; Orlikowski, D A; Peterson, S C; Satcher, J H; Elsholz, A J; Park, H-S; Remington, B A; Bazin, N; Foster, J M; Graham, P; Park, N; Rosen, P A; Rothman, S R; Higginbotham, A; Suggit, M; Wark, J S

    2013-03-15

    The strength of shock-loaded single crystal tantalum [100] has been experimentally determined using in situ broadband x-ray Laue diffraction to measure the strain state of the compressed crystal, and elastic constants calculated from first principles. The inferred strength reaches 35 GPa at a shock pressure of 181 GPa and is in excellent agreement with a multiscale strength model [N. R. Barton et al., J. Appl. Phys. 109, 073501 (2011)], which employs a hierarchy of simulation methods over a range of length scales to calculate strength from first principles.

  5. Temperature dependence of the hydrated electron's excited-state relaxation. I. Simulation predictions of resonance Raman and pump-probe transient absorption spectra of cavity and non-cavity models

    Science.gov (United States)

    Zho, Chen-Chen; Farr, Erik P.; Glover, William J.; Schwartz, Benjamin J.

    2017-08-01

    We use one-electron non-adiabatic mixed quantum/classical simulations to explore the temperature dependence of both the ground-state structure and the excited-state relaxation dynamics of the hydrated electron. We compare the results for both the traditional cavity picture and a more recent non-cavity model of the hydrated electron and make definite predictions for distinguishing between the different possible structural models in future experiments. We find that the traditional cavity model shows no temperature-dependent change in structure at constant density, leading to a predicted resonance Raman spectrum that is essentially temperature-independent. In contrast, the non-cavity model predicts a blue-shift in the hydrated electron's resonance Raman O-H stretch with increasing temperature. The lack of a temperature-dependent ground-state structural change of the cavity model also leads to a prediction of little change with temperature of both the excited-state lifetime and hot ground-state cooling time of the hydrated electron following photoexcitation. This is in sharp contrast to the predictions of the non-cavity model, where both the excited-state lifetime and hot ground-state cooling time are expected to decrease significantly with increasing temperature. These simulation-based predictions should be directly testable by the results of future time-resolved photoelectron spectroscopy experiments. Finally, the temperature-dependent differences in predicted excited-state lifetime and hot ground-state cooling time of the two models also lead to different predicted pump-probe transient absorption spectroscopy of the hydrated electron as a function of temperature. We perform such experiments and describe them in Paper II [E. P. Farr et al., J. Chem. Phys. 147, 074504 (2017)], and find changes in the excited-state lifetime and hot ground-state cooling time with temperature that match well with the predictions of the non-cavity model. In particular, the experiments

  6. Residue specific hydration of primary cell wall potato pectin identified by solid-state 13C single-pulse MAS and CP/MAS NMR spectroscopy

    DEFF Research Database (Denmark)

    Larsen, Flemming Hofmann; Chrestensen, Inge Byg; Damager, Iben

    2011-01-01

    Hydration of rhamnogalacturonan-I (RG-I) derived from potato cell wall was analyzed by 13C single-pulse (SP) magic-angle-spinning (MAS) and 13C cross-polarization (CP) MAS nuclear magnetic resonance (NMR) and supported by 2H SP/MAS NMR experiments. The study shows that the arabinan side chains...... hydrate more readily than the galactan side chains and suggests that the overall hydration properties can be controlled by modifying the ratio of these side chains. Enzymatic modification of native (NA) RG-I provided samples with reduced content of arabinan (sample DA), galactan (sample DG), or both side...... chains (sample DB). Results of these samples suggested that hydration properties were determined by the length and character of the side chains. NA and DA exhibited similar hydration characteristics, whereas DG and DB were difficult to hydrate because of the less hydrophilic properties of the rhamnose...

  7. Sampling system for fast single pulses; Realisation d'un dispositif d'echantillonnage d'un signal bref unique

    Energy Technology Data Exchange (ETDEWEB)

    Zenatti, D. [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1969-07-01

    Development of a device for the enlargement of the domain of application of classical oscilloscopes to the observation of fast single pulses by application of the sampling principle. Its principal characteristics are: Bandwidth of 700 MHz; Maximum sensibility of 50 mV; Maximum amplitude of input signal of {+-} 1 V; Number of samples of 16; Samples separation of 0,2 ns. (author) [French] Realisation d'un dispositif permettant d'elargir le domaine d'utilisation des oscilloscopes classiques en appliquant le principe de l'echantillonnage a l'observation d'un signal bref unique. Les principales caracteristiques sont les suivantes: Bande passante de 700 MHz; Sensibilite maximale de 50 mV; Amplitude maximale du signal a echantillonner de {+-} 1 V; Nombre de points d'echantillonnage de 16; Pas d'echantillonnage de 0,2 ns. (auteur)

  8. Single-shot full strain tensor determination with microbeam X-ray Laue diffraction and a two-dimensional energy-dispersive detector.

    Science.gov (United States)

    Abboud, A; Kirchlechner, C; Keckes, J; Conka Nurdan, T; Send, S; Micha, J S; Ulrich, O; Hartmann, R; Strüder, L; Pietsch, U

    2017-06-01

    The full strain and stress tensor determination in a triaxially stressed single crystal using X-ray diffraction requires a series of lattice spacing measurements at different crystal orientations. This can be achieved using a tunable X-ray source. This article reports on a novel experimental procedure for single-shot full strain tensor determination using polychromatic synchrotron radiation with an energy range from 5 to 23 keV. Microbeam X-ray Laue diffraction patterns were collected from a copper micro-bending beam along the central axis (centroid of the cross section). Taking advantage of a two-dimensional energy-dispersive X-ray detector (pnCCD), the position and energy of the collected Laue spots were measured for multiple positions on the sample, allowing the measurement of variations in the local microstructure. At the same time, both the deviatoric and hydrostatic components of the elastic strain and stress tensors were calculated.

  9. Disappearance of the laue spots of the downward X-ray diffraction and huge recoil Thomson scattering in solid helium as some prominent peculiarities of a quantum crystal

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Tetsuo

    1996-02-01

    In topographs of the downward X-ray diffraction, no Laue spots could be observed using a horizontally thin line-focussed beam. The disappearance of the Laue spots by the downward X-ray diffraction could be explained by two main factors besides a synergistic effect of the smallness of the atomic-scattering factors, the absorption coefficients, the densities etc. One is that the downward X-ray diffraction is completely inelastic scattering, and, as a result, diffracted X-ray beams may become entirely diffuse scattering. The other is that the great difference in the linear scatterer density between the forward and downward directions resulted from the fact that the irradiation of a line-focussed X-ray beam to take section topographs weakens the downward X-ray diffraction. The main reason is not due to the zero-point vibration. (J.P.N.).

  10. Disappearance of the laue spots of the downward X-ray diffraction and huge recoil Thomson scattering in solid helium as some prominent peculiarities of a quantum crystal

    International Nuclear Information System (INIS)

    Nakajima, Tetsuo.

    1996-02-01

    In topographs of the downward X-ray diffraction, no Laue spots could be observed using a horizontally thin line-focussed beam. The disappearance of the Laue spots by the downward X-ray diffraction could be explained by two main factors besides a synergistic effect of the smallness of the atomic-scattering factors, the absorption coefficients, the densities etc. One is that the downward X-ray diffraction is completely inelastic scattering, and, as a result, diffracted X-ray beams may become entirely diffuse scattering. The other is that the great difference in the linear scatterer density between the forward and downward directions resulted from the fact that the irradiation of a line-focussed X-ray beam to take section topographs weakens the downward X-ray diffraction. The main reason is not due to the zero-point vibration. (J.P.N.)

  11. Using coupled micropillar compression and micro-Laue diffraction to investigate deformation mechanisms in a complex metallic alloy Al{sub 13}Co{sub 4}

    Energy Technology Data Exchange (ETDEWEB)

    Bhowmik, Ayan, E-mail: a.bhowmik@ic.ac.uk; Britton, T. Ben; Sernicola, Giorgio; Dye, David [Department of Materials, Imperial College London, Exhibition Road, London SW7 2AZ (United Kingdom); Dolbnya, Igor P. [Diamond Light Source, Didcot, Oxfordshire OX11 0DE (United Kingdom); Jones, Nicholas G.; Walter, Claudia; Clegg, William J. [Department of Materials Science and Metallurgy, University of Cambridge, Cambridge CB3 0FS (United Kingdom); Gille, Peter [Crystallographic Section, Department of Earth and Environmental Sciences, Ludwig-Maximilians-Universität München, Munich D-80333 (Germany); Giuliani, Finn [Department of Materials, Imperial College London, Exhibition Road, London SW7 2AZ (United Kingdom); Department of Mechanical Engineering, Imperial College London, London SW7 2AZ (United Kingdom)

    2016-03-14

    In this study, we have used in-situ micro-Laue diffraction combined with micropillar compression of focused ion beam milled Al{sub 13}Co{sub 4} complex metallic alloy to investigate the evolution of deformation in Al{sub 13}Co{sub 4}. Streaking of the Laue spots shows that the onset of plastic flow occurs at stresses as low as 0.8 GPa, although macroscopic yield only becomes apparent at 2 GPa. The measured misorientations, obtained from peak splitting, enable the geometrically necessary dislocation density to be estimated as 1.1 × 10{sup 13 }m{sup −2}.

  12. Modulated crystal structures of VII and V phases in (NH4)3H(SO4)2. I. Neutron Laue diffraction

    International Nuclear Information System (INIS)

    McIntyre, G.; Smirnov, L.S.; Baranov, A.I.; Dolbinina, V.V.; Frontas'eva, M.V.; Pavlov, S.S.; Pankratova, Yu.S.

    2010-01-01

    The study of crystal structures of VII and V phases of (NH 4 ) 3 H(SO 4 ) 2 by means of neutron Laue diffraction is carried out at temperatures from 5 to 300 K. It is found that crystal structures of VII and V phases have incommensurate modulation with different periods, and phase transition from phase VII to phase V is transition of the first type

  13. Retrospective Study on Laser Treatment of Oral Vascular Lesions Using the "Leopard Technique": The Multiple Spot Irradiation Technique with a Single-Pulsed Wave.

    Science.gov (United States)

    Miyazaki, Hidetaka; Ohshiro, Takafumi; Romeo, Umberto; Noguchi, Tadahide; Maruoka, Yutaka; Gaimari, Gianfranco; Tomov, Georgi; Wada, Yoshitaka; Tanaka, Kae; Ohshiro, Toshio; Asamura, Shinichi

    2018-06-01

    This study aimed to retrospectively evaluate the efficacy and safety of laser treatment of oral vascular lesions using the multiple spot irradiation technique with a single-pulsed wave. In laser therapy for vascular lesions, heat accumulation induced by excessive irradiation can cause adverse events postoperatively, including ulcer formation, resultant scarring, and severe pain. To prevent heat accumulation and side effects, we have applied a multiple pulsed spot irradiation technique, the so-called "leopard technique" (LT) to oral vascular lesions. This approach was originally proposed for laser treatment of nevi. It can avoid thermal concentration at the same spot and spare the epithelium, which promotes smooth healing. The goal of the study was to evaluate this procedure and treatment outcomes. The subjects were 46 patients with 47 oral vascular lesions treated with the LT using a Nd:YAG laser (1064 nm), including 24 thick lesions treated using a combination of the LT and intralesional photocoagulation. All treatment outcomes were satisfactory without serious complications such as deep ulcer formation, scarring, bleeding, or severe swelling. Laser therapy with the LT is a promising less-invasive treatment for oral vascular lesions.

  14. Kinetics of the Thermal Decomposition of Tetramethylsilane behind the Reflected Shock Waves in a Single Pulse Shock Tube (SPST) and Modeling Study

    Science.gov (United States)

    Parandaman, A.; Sudhakar, G.; Rajakumar, B.

    Thermal reactions of Tetramethylsilane (TMS) diluted in argon were studied behind the reflected shock waves in a single-pulse shock tube (SPST) over the temperature range of 1085-1221 K and pressures varied between 10.6 and 22.8 atm. The stable products resulting from the decomposition of TMS were identified and quantified using gas chromatography and also verified with Fourier Transform Infrared (FTIR) spectrometer. The major reaction products are methane (CH4) and ethylene (C2H4). The minor reaction products are ethane (C2H6) and propylene (C3H6). The initiation of mechanism in the decomposition of TMS takes plays via the Si-C bond scission by ejecting the methyl radicals (CH3) and trimethylsilyl radicals ((CH3)3Si). The measured temperature dependent rate coefficient for the total decomposition of TMS was to be ktotal = 1.66 ×1015 exp (-64.46/RT) s-1 and for the formation of CH4 reaction channel was to be k = 2.20 × 1014 exp (-60.15/RT) s-1, where the activation energies are given in kcal mol-1. A kinetic scheme containing 17 species and 28 elementary reactions was used for the simulation using chemical kinetic simulator over the temperature range of 1085-1221 K. The agreement between the experimental and simulated results was satisfactory.

  15. Assessment of Event-Related EEG Power After Single-Pulse TMS in Unresponsive Wakefulness Syndrome and Minimally Conscious State Patients.

    Science.gov (United States)

    Formaggio, Emanuela; Cavinato, Marianna; Storti, Silvia Francesca; Tonin, Paolo; Piccione, Francesco; Manganotti, Paolo

    2016-03-01

    In patients without a behavioral response, non-invasive techniques and new methods of data analysis can complement existing diagnostic tools by providing a method for detecting covert signs of residual cognitive function and awareness. The aim of this study was to investigate the brain oscillatory activities synchronized by single-pulse transcranial magnetic stimulation (TMS) delivered over the primary motor area in the time-frequency domain in patients with the unresponsive wakefulness syndrome or in a minimally conscious state as compared to healthy controls. A time-frequency analysis based on the wavelet transform was used to characterize rapid modifications of oscillatory EEG rhythms induced by TMS in patients as compared to healthy controls. The pattern of EEG changes in the patients differed from that of healthy controls. In the controls there was an early synchronization of slow waves immediately followed by a desynchronization of alpha and beta frequency bands over the frontal and centro-parietal electrodes, whereas an opposite early synchronization, particularly over motor areas for alpha and beta and over the frontal and parietal electrodes for beta power, was seen in the patients. In addition, no relevant modification in slow rhythms (delta and theta) after TMS was noted in patients. The clinical impact of these findings could be relevant in neurorehabilitation settings for increasing the awareness of these patients and defining new treatment procedures.

  16. Towards diffractive imaging with single pulses of FEL radiation. Dynamics within irradiatied samples and their influence on the analysis of imaging data

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Fenglin

    2010-08-15

    3D single particle coherent diffraction imaging (CDI) of bioparticles (such as proteins, macromolecules and viruses) is one of the main possible applications of the new generation of light sources: free-electron lasers (FELs), which are now available at FLASH (Hamburg, Germany) and LCLS (Stanford, U.S.A.). The extremely bright and ultrashort FEL pulses potentially enable CDI to achieve high resolution down to subnanometer length scale. However, intense FEL pulses cause serious radiation damage in bioparticles, even during single shots, which may set the resolution limits for CDI with FELs. Currently, since the signal-to-noise ratio is very low for small biological particles, direct experimental study of radiation damage in the single particle imaging is fairly difficult. Single atomic (noble gas) clusters become good objects to reveal effects of radiation damage processes on CDI with FEL radiation. This thesis studies three aspects of the radiation damage problem, which are treated in three independent chapters: (1) Molecular Dynamics simulations to quantitively describe radiation damage processes within irradiated atomic clusters during single pulses; (2) reconstruction analysis of single-shot CDI diffraction patterns of atomic clusters, which may potentially help to understand the radiation damage occurring in biological samples; and (3) testing the effects of coating water layers in CDI, which is supposed to minimize the radiation damage in irradiated bioparticles. (orig.)

  17. A new method for polychromatic X-ray μLaue diffraction on a Cu pillar using an energy-dispersive pn-junction charge-coupled device

    Energy Technology Data Exchange (ETDEWEB)

    Abboud, A.; Send, S.; Pashniak, N.; Pietsch, U. [Department of Physics, University of Siegen, Siegen 57072 (Germany); Kirchlechner, C. [Max-Planck-Institut für Eisenforschung GmbH, Düsseldorf 40237 (Germany); Montanuniversität Leoben, Leoben 8700 (Austria); Micha, J. S.; Ulrich, O. [CEA-Grenoble/DRFMC/SprAM, 17 rue des Martyrs, Grenoble Cedex 9, F-38054 (France); Strüder, L. [PNSensor GmbH, Munich 80803 (Germany); Keckes, J. [Montanuniversität Leoben, Leoben 8700 (Austria); Material Center Leoben Forschungs GmbH, Leoben 8700 (Austria)

    2014-11-15

    μLaue diffraction with a polychromatic X-ray beam can be used to measure strain fields and crystal orientations of micro crystals. The hydrostatic strain tensor can be obtained once the energy profile of the reflections is measured. However, this remains a challenge both on the time scale and reproducibility of the beam position on the sample. In this review, we present a new approach to obtain the spatial and energy profiles of Laue spots by using a pn-junction charge-coupled device, an energy-dispersive area detector providing 3D resolution of incident X-rays. The morphology and energetic structure of various Bragg peaks from a single crystalline Cu micro-cantilever used as a test system were simultaneously acquired. The method facilitates the determination of the Laue spots’ energy spectra without filtering the white X-ray beam. The synchrotron experiment was performed at the BM32 beamline of ESRF using polychromatic X-rays in the energy range between 5 and 25 keV and a beam size of 0.5 μm × 0.5 μm. The feasibility test on the well known system demonstrates the capabilities of the approach and introduces the “3D detector method” as a promising tool for material investigations to separate bending and strain for technical materials.

  18. Wake monochromator in asymmetric and symmetric Bragg and Laue geometry for self-seeding the European X-ray FEL

    International Nuclear Information System (INIS)

    Geloni, Gianluca; Kocharyan, Vitali; Saldin, Evgeni; Serkez, Svitozar; Tolkiehn, Martin

    2013-01-01

    We discuss the use of self-seeding schemes with wake monochromators to produce TW power, fully coherent pulses for applications at the dedicated bio-imaging beamline at the European X-ray FEL, a concept for an upgrade of the facility beyond the baseline previously proposed by the authors. We exploit the asymmetric and symmetric Bragg and Laue reflections (sigma polarization) in diamond crystal. Optimization of the bio-imaging beamline is performed with extensive start-to-end simulations, which also take into account effects such as the spatio-temporal coupling caused by the wake monochromator. The spatial shift is maximal in the range for small Bragg angles. A geometry with Bragg angles close to π/2 would be a more advantageous option from this viewpoint, albeit with decrease of the spectral tunability. We show that it will be possible to cover the photon energy range from 3 keV to 13 keV by using four different planes of the same crystal with one rotational degree of freedom.

  19. Wake monochromator in asymmetric and symmetric Bragg and Laue geometry for self-seeding the European X-ray FEL

    Energy Technology Data Exchange (ETDEWEB)

    Geloni, Gianluca [European XFEL GmbH, Hamburg (Germany); Kocharyan, Vitali; Saldin, Evgeni; Serkez, Svitozar; Tolkiehn, Martin [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2013-01-15

    We discuss the use of self-seeding schemes with wake monochromators to produce TW power, fully coherent pulses for applications at the dedicated bio-imaging beamline at the European X-ray FEL, a concept for an upgrade of the facility beyond the baseline previously proposed by the authors. We exploit the asymmetric and symmetric Bragg and Laue reflections (sigma polarization) in diamond crystal. Optimization of the bio-imaging beamline is performed with extensive start-to-end simulations, which also take into account effects such as the spatio-temporal coupling caused by the wake monochromator. The spatial shift is maximal in the range for small Bragg angles. A geometry with Bragg angles close to {pi}/2 would be a more advantageous option from this viewpoint, albeit with decrease of the spectral tunability. We show that it will be possible to cover the photon energy range from 3 keV to 13 keV by using four different planes of the same crystal with one rotational degree of freedom.

  20. Formulation of dynamical theory of X-ray diffraction for perfect crystals in the Laue case using the Riemann surface.

    Science.gov (United States)

    Saka, Takashi

    2016-05-01

    The dynamical theory for perfect crystals in the Laue case was reformulated using the Riemann surface, as used in complex analysis. In the two-beam approximation, each branch of the dispersion surface is specified by one sheet of the Riemann surface. The characteristic features of the dispersion surface are analytically revealed using four parameters, which are the real and imaginary parts of two quantities specifying the degree of departure from the exact Bragg condition and the reflection strength. By representing these parameters on complex planes, these characteristics can be graphically depicted on the Riemann surface. In the conventional case, the absorption is small and the real part of the reflection strength is large, so the formulation is the same as the traditional analysis. However, when the real part of the reflection strength is small or zero, the two branches of the dispersion surface cross, and the dispersion relationship becomes similar to that of the Bragg case. This is because the geometrical relationships among the parameters are similar in both cases. The present analytical method is generally applicable, irrespective of the magnitudes of the parameters. Furthermore, the present method analytically revealed many characteristic features of the dispersion surface and will be quite instructive for further numerical calculations of rocking curves.

  1. Some feature of interpretation of tension single pulsed electromagnetic field of the Earth to create the model parameter fields physical properties

    Directory of Open Access Journals (Sweden)

    Mokritskaya T.P.

    2014-12-01

    Full Text Available Stochastic analysis of the results of different methods of obtaining and processing of information allows us to solve problems on a qualitatively different level. This is important when creating complex earth models and fields of its parameters, particularly the physical properties. Application of remote sensing methods (geophysical investigations with the registration of a single pulse intensity of the electromagnetic field of the Earth (EIEMPZ seismic profiling, is expanding. Interesting results of the joint interpretation of the results of geophysical and laboratory studies of physical soil. Interesting results of the joint interpretation of the results of geophysical and laboratory studies of physical soil. For the first time a methodology for assessing the state of the soil [3] applied for a joint interpretation of materials determine the field strength EMPZ, seismic profiling, and laboratory techniques. This has allowed to characterize the state of the geological environment and to build a model of inhomogeneous density distribution of fractured rocks at depth. In this paper we made a mathematical analysis of the results of research and talus deposits eluvial clay Taurian series, studied at one of the construction sites southern coast at a depth of 12.0 -25.0 m. Methods of statistical analysis, assessment of homogeneity and symmetrically distributed, rank correlation and multiple regression analysis described in [3]. The analysis of the spatial distribution of areas extrem value of EMPZ, heterogeneity of seismic rigidity. Statistical characteristics of indicators of physical properties reflect the genetic characteristics of the formation and the current state of silty-clay sediments of different genesis.It is proved that the regression model can be applied to interpret the state of the array in the construction of geodynamic model. It is established that the creation of forward-looking (dynamic models for the distribution of the physical

  2. Applications of a pnCCD detector coupled to columnar structure CsI(Tl) scintillator system in ultra high energy X-ray Laue diffraction

    Science.gov (United States)

    Shokr, M.; Schlosser, D.; Abboud, A.; Algashi, A.; Tosson, A.; Conka, T.; Hartmann, R.; Klaus, M.; Genzel, C.; Strüder, L.; Pietsch, U.

    2017-12-01

    Most charge coupled devices (CCDs) are made of silicon (Si) with typical active layer thicknesses of several microns. In case of a pnCCD detector the sensitive Si thickness is 450 μm. However, for silicon based detectors the quantum efficiency for hard X-rays drops significantly for photon energies above 10 keV . This drawback can be overcome by combining a pixelated silicon-based detector system with a columnar scintillator. Here we report on the characterization of a low noise, fully depleted 128×128 pixels pnCCD detector with 75×75 μm2 pixel size coupled to a 700 μm thick columnar CsI(Tl) scintillator in the photon range between 1 keV to 130 keV . The excellent performance of the detection system in the hard X-ray range is demonstrated in a Laue type X-ray diffraction experiment performed at EDDI beamline of the BESSY II synchrotron taken at a set of several GaAs single crystals irradiated by white synchrotron radiation. With the columnar structure of the scintillator, the position resolution of the whole system reaches a value of less than one pixel. Using the presented detector system and considering the functional relation between indirect and direct photon events Laue diffraction peaks with X-ray energies up to 120 keV were efficiently detected. As one of possible applications of the combined CsI-pnCCD system we demonstrate that the accuracy of X-ray structure factors extracted from Laue diffraction peaks can be significantly improved in hard X-ray range using the combined CsI(Tl)-pnCCD system compared to a bare pnCCD.

  3. Trajectory method in the theory of Laue diffraction of X rays in crystals: II. Effect of total reflection at bending deformation

    International Nuclear Information System (INIS)

    Kohn, V. G.

    2008-01-01

    The effect of total reflection (switching) of a spherical X-ray wave in the case of Laue diffraction in a crystal with bending deformation is analyzed by the trajectory method. Qualitative analytical description and computation of the spatial structure of the reflected beam for large and small distances between the spherical-wave source and the crystal are performed. The mechanism of much more efficient reflection of an X-ray beam by a deformed crystal in comparison with a perfect crystal is clearly demonstrated. It is also shown that the trajectory method is very convenient for description of the total reflection phenomenon.

  4. Trajectory method in the theory of Laue diffraction of X rays in crystals: II. Effect of total reflection at bending deformation

    International Nuclear Information System (INIS)

    Kohn, V. G.

    2008-01-01

    The effect of total reflection (switching) of a spherical X-ray wave in the case of Laue diffraction in a crystal with bending deformation is analyzed by the trajectory method. Qualitative analytical description and computation of the spatial structure of the reflected beam for large and small distances between the spherical-wave source and the crystal are performed. The mechanism of much more efficient reflection of an X-ray beam by a deformed crystal in comparison with a perfect crystal is clearly demonstrated. It is also shown that the trajectory method is very convenient for description of the total reflection phenomenon

  5. Computer simulation on spatial resolution of X-ray bright-field imaging by dynamical diffraction theory for a Laue-case crystal analyzer

    International Nuclear Information System (INIS)

    Suzuki, Yoshifumi; Chikaura, Yoshinori; Ando, Masami

    2011-01-01

    Recently, dark-field imaging (DFI) and bright-field imaging (BFI) have been proposed and applied to visualize X-ray refraction effects yielded in biomedical objects. In order to clarify the spatial resolution due to a crystal analyzer in Laue geometry, a program based on the Takagi-Taupin equation was modified to be used for carrying out simulations to evaluate the spatial resolution of images coming into a Laue angular analyzer (LAA). The calculation was done with a perfect plane wave for diffraction wave-fields, which corresponded to BFI, under the conditions of 35 keV and a diffraction index 440 for a 2100 μm thick LAA. As a result, the spatial resolution along the g-vector direction showed approximately 37.5 μm. 126 μm-thick LAA showed a spatial resolution better than 3.1 μm under the conditions of 13.7 keV and a diffraction index 220.

  6. Three-energy focusing Laue monochromator for the diamond light source x-ray pair distribution function beamline I15-1

    Energy Technology Data Exchange (ETDEWEB)

    Sutter, John P., E-mail: john.sutter@diamond.ac.uk; Chater, Philip A.; Hillman, Michael R.; Keeble, Dean S.; Wilhelm, Heribert [Diamond Light Source Ltd, Harwell Science and Innovation Campus, Chilton, Didcot, Oxfordshire OX11 0DE (United Kingdom); Tucker, Matt G. [Diamond Light Source Ltd, Harwell Science and Innovation Campus, Chilton, Didcot, Oxfordshire OX11 0DE (United Kingdom); ISIS Neutron and Muon Source, Science and Technology Facilities Council, Rutherford Appleton Laboratory, Harwell Oxford, Didcot, Oxfordshire OX11 0QX (United Kingdom)

    2016-07-27

    The I15-1 beamline, the new side station to I15 at the Diamond Light Source, will be dedicated to the collection of atomic pair distribution function data. A Laue monochromator will be used consisting of three silicon crystals diffracting X-rays at a common Bragg angle of 2.83°. The crystals use the (1 1 1), (2 2 0), and (3 1 1) planes to select 40, 65, and 76 keV X-rays, respectively, and will be bent meridionally to horizontally focus the selected X-rays onto the sample. All crystals will be cut to the same optimized asymmetry angle in order to eliminate image broadening from the crystal thickness. Finite element calculations show that the thermal distortion of the crystals will affect the image size and bandpass.

  7. Three-energy focusing Laue monochromator for the diamond light source x-ray pair distribution function beamline I15-1

    International Nuclear Information System (INIS)

    Sutter, John P.; Chater, Philip A.; Hillman, Michael R.; Keeble, Dean S.; Wilhelm, Heribert; Tucker, Matt G.

    2016-01-01

    The I15-1 beamline, the new side station to I15 at the Diamond Light Source, will be dedicated to the collection of atomic pair distribution function data. A Laue monochromator will be used consisting of three silicon crystals diffracting X-rays at a common Bragg angle of 2.83°. The crystals use the (1 1 1), (2 2 0), and (3 1 1) planes to select 40, 65, and 76 keV X-rays, respectively, and will be bent meridionally to horizontally focus the selected X-rays onto the sample. All crystals will be cut to the same optimized asymmetry angle in order to eliminate image broadening from the crystal thickness. Finite element calculations show that the thermal distortion of the crystals will affect the image size and bandpass.

  8. Femtosecond pump-probe studies of zinc phthalocynine in DMSO

    CSIR Research Space (South Africa)

    Ombinda-Lemboumba, Saturnin

    2010-09-01

    Full Text Available photosensitisers that can be clinically used as photodynamic cancer drug. The zinc phthalocyanine (ZnPc) has been reported to have suitable photophysical properties in photodynamic therapy. Recent work done on zinc phthalocyanine dynamic has proven that the energy...

  9. Holography and thermalization in optical pump-probe spectroscopy

    Science.gov (United States)

    Bagrov, A.; Craps, B.; Galli, F.; Keränen, V.; Keski-Vakkuri, E.; Zaanen, J.

    2018-04-01

    Using holography, we model experiments in which a 2 +1 D strange metal is pumped by a laser pulse into a highly excited state, after which the time evolution of the optical conductivity is probed. We consider a finite-density state with mildly broken translation invariance and excite it by oscillating electric field pulses. At zero density, the optical conductivity would assume its thermalized value immediately after the pumping has ended. At finite density, pulses with significant dc components give rise to slow exponential relaxation, governed by a vector quasinormal mode. In contrast, for high-frequency pulses the amplitude of the quasinormal mode is strongly suppressed, so that the optical conductivity assumes its thermalized value effectively instantaneously. This surprising prediction may provide a stimulus for taking up the challenge to realize these experiments in the laboratory. Such experiments would test a crucial open question faced by applied holography: are its predictions artifacts of the large N limit or do they enjoy sufficient UV independence to hold at least qualitatively in real-world systems?

  10. Fast and accurate methods for the performance testing of highly-efficient c-Si photovoltaic modules using a 10 ms single-pulse solar simulator and customized voltage profiles

    International Nuclear Information System (INIS)

    Virtuani, A; Rigamonti, G; Friesen, G; Chianese, D; Beljean, P

    2012-01-01

    Performance testing of highly efficient, highly capacitive c-Si modules with pulsed solar simulators requires particular care. These devices in fact usually require a steady-state solar simulator or pulse durations longer than 100–200 ms in order to avoid measurement artifacts. The aim of this work was to validate an alternative method for the testing of highly capacitive c-Si modules using a 10 ms single pulse solar simulator. Our approach attempts to reconstruct a quasi-steady-state I–V (current–voltage) curve of a highly capacitive device during one single 10 ms flash by applying customized voltage profiles–-in place of a conventional V ramp—to the terminals of the device under test. The most promising results were obtained by using V profiles which we name ‘dragon-back’ (DB) profiles. When compared to the reference I–V measurement (obtained by using a multi-flash approach with approximately 20 flashes), the DB V profile method provides excellent results with differences in the estimation of P max (as well as of I sc , V oc and FF) below ±0.5%. For the testing of highly capacitive devices the method is accurate, fast (two flashes—possibly one—required), cost-effective and has proven its validity with several technologies making it particularly interesting for in-line testing. (paper)

  11. Nanosecond time measurements of single pulse

    International Nuclear Information System (INIS)

    Xing Jingyuan; Cheng Shiyuan

    1986-01-01

    This report mainly describes the principle specification of circuit design and time-interval calibrations of model SHS 500 time-to-digital converter. Its range is 12 to 500 ns, with six ranges: 50, 100, 200, 300, 400 and 500 ns. The precision of measured time-interval is 0.3% of full scale and time resolution is 0.1% of full scale

  12. Searching for Single Pulses Using Heimdall

    Science.gov (United States)

    Walsh, Gregory; Lynch, Ryan

    2018-01-01

    In radio pulsar surveys, the interstellar medium causes a frequency dependent dispersive delay of a pulsed signal across the observing band. If not corrected, this delay substantially lowers S/N and makes most pulses undetectable. The delay is proportional to an unknown dispersion measure (DM), which must be searched over with many trial values. A number of new, GPU-accelerated codes are now available to optimize this dedispersion task, and to search for transient pulsed radio emission. We report on the use of Heimdall, one such GPU-accelerated tree dedispersion utility, to search for transient radio sources in a Green Bank Telescope survey of the Cygnus Region and North Galactic Plane. The survey is carried out at central frequency of 820 MHz with a goal of finding Fast Radio Bursts, Rotating Radio Transients, young pulsars, and millisecond pulsars. We describe the the survey, data processing pipeline, and follow-up of candidate sources.

  13. Preliminary 3D In-situ measurements of the texture evolution of strained H2O ice during annealing using neutron Laue diffractometry

    Science.gov (United States)

    Journaux, Baptiste; Montagnat, Maurine; Chauve, Thomas; Ouladdiaf, Bachir; Allibon, John

    2015-04-01

    Dynamic recrystallization (DRX) strongly affects the evolution of microstructure (grain size and shape) and texture (crystal preferred orientation) in materials during deformation at high temperature. Since texturing leads to anisotropic physical properties, predicting the effect of DRX is essential for industrial applications, for interpreting geophysical data and modeling geodynamic flows, and predicting ice sheet flow and climate evolution. A large amount of literature is available related to metallurgy, geology or glaciology, but there remains overall fundamental questions about the relationship between nucleation, grain boundary migration and texture development at the microscopic scale. Previous measurements of DRX in ice were either conducted using 2D ex-situ techniques such as AITA [1,2] or Electron Backscattering Diffraction (EBSD) [3], or using 3D statistical ex-situ [4] or in-situ [5] techniques. Nevertheless, all these techniques failed to observe at the scale of nucleation processes during DRX in full 3D. Here we present a new approach using neutron Laue diffraction, which enable to perform 3D measurements of in-situ texture evolution of strained polycrystalline H2O ice (>2% at 266 K) during annealing at the microscopic scale. Thanks the CYCLOPS instrument [6] (Institut Laue Langevin Grenoble, France) and the intrinsic low background of this setup, preliminary observations enabled us to follow, in H2O ice, the evolution of serrated grain boundaries, and kink-band during annealing. Our observations show a significant evolution of the texture and internal misorientation over the course of few hours at an annealing temperature of 268.5 K. In the contrary, ice kink-band structures seem to be very stable over time at near melting temperatures. The same samples have been analyzed ex-situ using EBSD for comparison. These results represent a first step toward in-situ microscopic measurements of dynamic recrystallization processes in ice during strain. This

  14. Innovation and optimization of a method of pump-probe polarimetry with pulsed laser beams in view of a precise measurement of parity violation in atomic cesium; Innovation et optimisation d'une methode de polarimetrie pompe-sonde avec des faisceaux laser impulsionnels en vue d'une mesure precise de violation de la parite dans l'atome de cesium

    Energy Technology Data Exchange (ETDEWEB)

    Chauvat, D

    1997-10-15

    While Parity Violation (PV) experiments on highly forbidden transitions have been using detection of fluorescence signals; our experiment uses a pump-probe scheme to detect the PV signal directly on a transmitted probe beam. A pulsed laser beam of linear polarisation {epsilon}{sub 1} excites the atoms on the 6S-7S cesium transition in a colinear electric field E || k(ex). The probe beam (k(pr) || k(ex)) of linear polarisation {epsilon}{sub 2} tuned to the transition 7S-6P(3/2) is amplified. The small asymmetry ({approx} 10{sup -6}) in the gain that depends on the handedness of the tri-hedron (E, {epsilon}{sub 1}, {epsilon}{sub 2}) is the manifestation of the PV effect. This is measured as an E-odd apparent rotation of the plane of polarization of the probe beam; using balanced mode polarimetry. New criteria of selection have been devised, that allow us to distinguish the true PV-signal against fake rotations due to electromagnetic interferences, geometrical effects, polarization imperfections, or stray transverse electric and magnetic fields. These selection criteria exploit the symmetry of the PV-rotation - linear dichroism - and the revolution symmetry of the experiment. Using these criteria it is not only possible to reject fake signals, but also to elucidate the underlying physical mechanisms and to measure the relevant defects of the apparatus. The present signal-to-noise ratio allows embarking in PV measurements to reach the 10% statistical accuracy. A 1% measurement still requires improvements. Two methods have been demonstrated. The first one exploits the amplification of the asymmetry at high gain - one major advantage provided by our detection method based on stimulated emission. The second method uses both a much higher incident intensity and a special dichroic component which magnifies tiny polarization rotations. (author)

  15. Study of optical Laue diffraction

    International Nuclear Information System (INIS)

    Chakravarthy, Giridhar; Allam, Srinivasa Rao; Satyanarayana, S. V. M.; Sharan, Alok

    2014-01-01

    We present the study of the optical diffraction pattern of one and two-dimensional gratings with defects, designed using desktop pc and printed on OHP sheet using laser printer. Gratings so prepared, using novel low cost technique provides good visual aid in teaching. Diffraction pattern of the monochromatic light (632.8nm) from the grating so designed is similar to that of x-ray diffraction pattern of crystal lattice with point defects in one and two-dimensions. Here both optical and x-ray diffractions are Fraunhofer. The information about the crystalline lattice structure and the defect size can be known

  16. Study of optical Laue diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Chakravarthy, Giridhar, E-mail: cgiridhar84@gmail.com, E-mail: aloksharan@email.com; Allam, Srinivasa Rao, E-mail: cgiridhar84@gmail.com, E-mail: aloksharan@email.com; Satyanarayana, S. V. M., E-mail: cgiridhar84@gmail.com, E-mail: aloksharan@email.com; Sharan, Alok, E-mail: cgiridhar84@gmail.com, E-mail: aloksharan@email.com [Department of Physics, Pondicherry University, Puducherry-605014 (India)

    2014-10-15

    We present the study of the optical diffraction pattern of one and two-dimensional gratings with defects, designed using desktop pc and printed on OHP sheet using laser printer. Gratings so prepared, using novel low cost technique provides good visual aid in teaching. Diffraction pattern of the monochromatic light (632.8nm) from the grating so designed is similar to that of x-ray diffraction pattern of crystal lattice with point defects in one and two-dimensions. Here both optical and x-ray diffractions are Fraunhofer. The information about the crystalline lattice structure and the defect size can be known.

  17. Decision no. 2011-DC-0216 of the French nuclear safety authority from May 5, 2011, ordering the Laue Langevin Institute to proceed to a complementary safety evaluation of its basic nuclear facility (high flux reactor - INB no. 67) in the eyes of the Fukushima Daiichi nuclear power plant accident

    International Nuclear Information System (INIS)

    2011-01-01

    As a consequence of the accident of the Fukushima Daiichi nuclear power plant (Japan), the French Prime Minister entrusted the French nuclear safety authority (ASN) with the mission to carry out a safety analysis re-evaluation of the French nuclear facilities, and in particular the nuclear power plants. A decision has been addressed by the ASN to each nuclear operator with the specifications of this safety re-evaluation analysis and the list of facilities in concern. This document is the decision addressed to the Laue Langevin Institute, operator of the high flux research reactor (RHF) of Grenoble (France). (J.S.)

  18. The pump-probe coupling of matter wave packets to remote lattice states

    DEFF Research Database (Denmark)

    Sherson, Jacob F; Park, Sung Jong; Pedersen, Poul Lindholm

    2012-01-01

    containing a Bose–Einstein condensate. The evolution of these wave packets is monitored in situ and their six-photon reflection at a band gap is observed. In direct analogy with pump–probe spectroscopy, a probe pulse allows for the resonant de-excitation of the wave packet into states localized around...... selected lattice sites at a long, controllable distance of more than 100 lattice sites from the main component. This precise control mechanism for ultra-cold atoms thus enables controlled quantum state preparation and splitting for quantum dynamics, metrology and simulation....

  19. Pump-probe nonlinear magneto-optical rotation with frequency-modulated light

    International Nuclear Information System (INIS)

    Pustelny, S.; Gawlik, W.; Jackson Kimball, D. F.; Rochester, S. M.; Yashchuk, V. V.; Budker, D.

    2006-01-01

    Specific types of atomic coherences between Zeeman sublevels can be generated and detected using a method based on nonlinear magneto-optical rotation with frequency-modulated light. Linearly polarized, frequency-modulated light is employed to selectively generate ground-state coherences between Zeeman sublevels for which Δm=2 and Δm=4 in 85 Rb and 87 Rb atoms, and additionally Δm=6 in 85 Rb. The atomic coherences are detected with a separate, unmodulated probe light beam. Separation of the pump and probe beams enables independent investigation of the processes of creation and detection of the atomic coherences. With the present technique the transfer of the Zeeman coherences, including high-order coherences, from excited to ground state by spontaneous emission has been observed

  20. Pump-probe differencing technique for cavity-enhanced, noise-canceling saturation laser spectroscopy.

    Science.gov (United States)

    de Vine, Glenn; McClelland, David E; Gray, Malcolm B; Close, John D

    2005-05-15

    We present an experimental technique that permits mechanical-noise-free, cavity-enhanced frequency measurements of an atomic transition and its hyperfine structure. We employ the 532-nm frequency-doubled output from a Nd:YAG laser and an iodine vapor cell. The cell is placed in a folded ring cavity (FRC) with counterpropagating pump and probe beams. The FRC is locked with the Pound-Drever-Hall technique. Mechanical noise is rejected by differencing the pump and probe signals. In addition, this differenced error signal provides a sensitive measure of differential nonlinearity within the FRC.

  1. Toward sub-femtosecond pump-probe experiments: a dispersionless autocorrelator with attosecond resolution

    Energy Technology Data Exchange (ETDEWEB)

    Constant, E.; Mevel, E.; Zair, A.; Bagnoud, V.; Salin, F. [Bordeaux-1 Univ., Talence (FR). Centre Lasers Intenses et Applications (CELIA)

    2001-07-01

    We designed a dispersionless autocorrelator with a sub-femtosecond resolution suitable for the characterization of ultrashort X-UV pulses. We present a proof of feasibility experiment with 11 fs infrared pulses. (orig.)

  2. Patterning effects in quantum dot amplifiers characterized through pump probe spectroscopy using two pump pulses

    DEFF Research Database (Denmark)

    Berg, Tommy Winther; Poel, Mike van der; Laemmlin, M.

    2004-01-01

    Patterning effects at ultrahigh bitrates in quantum dot amplifiers are investigated by a novel experimental technique. Slow carrier dynamics in the excited states and wetting layer are found to limit the potential for ultrahigh-speed signal processing....

  3. Ultra-fast pump-probe determination of electron-phonon coupling in cuprate superconductors

    Science.gov (United States)

    Mihailovic, Dragan

    2010-03-01

    Fresh femtosecond spectroscopy experiments show the electron-phonon interaction strength λ to be 0.7 and 1.4 for YBCO and LSCO respectively and not around 0.2 as previously reported [1]. The revised estimates arise primarily from improved time-resolution, and also partly from improved modeling. Comparison with classical superconductors and pnictides shows non-monotonic correlation of λ with Tc. Systematic new measurements of the condensate vaporization energy (Uv) in cuprates [2] and pnictides reveals a power-law dependence on Tc with exponent 2. However, Uc is 16-18 times greater than the BCS condensation energy Uc, implying that a significant heat capacity of the ``bosonic glue.'' In contrast, charge-density wave systems with electronically driven ordering transitions have Uv˜Uc. The data suggest BCS and Eliashberg-based models to be inappropriate for describing the physics of high-temperature superconductors, and point towards polaron models which consider strong or intermediate λ.[4pt] [1] C.Gadermeier et al., arXiv:0902.1636[0pt] [2] P.Kusar et al., Phys. Rev. Lett. 101, 227001 (2008)

  4. Versatile ultrafast pump-probe imaging with high sensitivity CCD camera

    OpenAIRE

    Pezeril , Thomas; Klieber , Christoph; Temnov , Vasily; Huntzinger , Jean-Roch; Anane , Abdelmadjid

    2012-01-01

    International audience; A powerful imaging technique based on femtosecond time-resolved measurements with a high dynamic range, commercial CCD camera is presented. Ultrafast phenomena induced by a femtosecond laser pump are visualized through the lock-in type acquisition of images recorded by a femtosecond laser probe. This technique allows time-resolved measurements of laser excited phenomena at multiple probe wavelengths (spectrometer mode) or conventional imaging of the sample surface (ima...

  5. Single pulse analysis of intracranial pressure for a hydrocephalus implant.

    Science.gov (United States)

    Elixmann, I M; Hansinger, J; Goffin, C; Antes, S; Radermacher, K; Leonhardt, S

    2012-01-01

    The intracranial pressure (ICP) waveform contains important diagnostic information. Changes in ICP are associated with changes of the pulse waveform. This change has explicitly been observed in 13 infusion tests by analyzing 100 Hz ICP data. An algorithm is proposed which automatically extracts the pulse waves and categorizes them into predefined patterns. A developed algorithm determined 88 %±8 % (mean ±SD) of all classified pulse waves correctly on predefined patterns. This algorithm has low computational cost and is independent of a pressure drift in the sensor by using only the relationship between special waveform characteristics. Hence, it could be implemented on a microcontroller of a future electromechanic hydrocephalus shunt system to control the drainage of cerebrospinal fluid (CSF).

  6. Trichloroethylene (TCE) removal in a single pulse suspension bioreactor

    Czech Academy of Sciences Publication Activity Database

    Volčík, V.; Hoffmann, J.; Růžička, J.; Sergejevova, Magda

    2005-01-01

    Roč. 74, - (2005), s. 293-304 ISSN 0301-4797 R&D Projects: GA MŠk LN00A141 Institutional research plan: CEZ:AV0Z50200510 Keywords : trichlorethylene * phenol * cometabolism Subject RIV: EE - Microbiology, Virology Impact factor: 1.163, year: 2005

  7. Cooling the vertical surface by conditionally single pulses

    Directory of Open Access Journals (Sweden)

    Karpov Pavel

    2017-01-01

    Full Text Available You Sprays with periodic supply of the droplet phase have great opportunities to control the heat exchange processes. Varying pulse duration and frequency of their repetition, we can achieve the optimal conditions of evaporative cooling with minimization of the liquid flow rate. The paper presents experimental data on studying local heat transfer on a large subcooled surface, obtained on the original setup with multinozzle controlled system of impact irrigation by the gas-droplet flow. A contribution to intensification of the spray parameters (flow rate, pulse duration, repetition frequency per a growth of integral heat transfer was studied. Data on instantaneous distribution of the heat flux value helped us to describe the processes occurring on the studied surface. These data could describe the regime of “island” film cooling.

  8. Cooling the vertical surface by conditionally single pulses

    Science.gov (United States)

    Karpov, Pavel; Nazarov, Alexander; Serov, Anatoly; Terekhov, Victor

    2017-10-01

    You Sprays with periodic supply of the droplet phase have great opportunities to control the heat exchange processes. Varying pulse duration and frequency of their repetition, we can achieve the optimal conditions of evaporative cooling with minimization of the liquid flow rate. The paper presents experimental data on studying local heat transfer on a large subcooled surface, obtained on the original setup with multinozzle controlled system of impact irrigation by the gas-droplet flow. A contribution to intensification of the spray parameters (flow rate, pulse duration, repetition frequency) per a growth of integral heat transfer was studied. Data on instantaneous distribution of the heat flux value helped us to describe the processes occurring on the studied surface. These data could describe the regime of "island" film cooling.

  9. X-Ray Emission Spectrometer Design with Single-Shot Pump-Probe and Resonant Excitation Capabilities

    Energy Technology Data Exchange (ETDEWEB)

    Spoth, Katherine; /SUNY, Buffalo /SLAC

    2012-08-28

    Core-level spectroscopy in the soft X-ray regime is a powerful tool for the study of chemical bonding processes. The ultrafast, ultrabright X-ray pulses generated by the Linac Coherent Light Source (LCLS) allow these reactions to be studied in greater detail than ever before. In this study, we investigated a conceptual design of a spectrometer for the LCLS with imaging in the non-dispersive direction. This would allow single-shot collection of X-ray emission spectroscopy (XES) measurements with varying laser pump X-ray probe delay or a variation of incoming X-ray energy over the illuminated area of the sample. Ray-tracing simulations were used to demonstrate how the components of the spectrometer affect its performance, allowing a determination of the optimal final design. These simulations showed that the spectrometer's non-dispersive focusing is extremely sensitive to the size of the sample footprint; the spectrometer is not able to image a footprint width larger than one millimeter with the required resolution. This is compatible with a single shot scheme that maps out the laser pump X-ray probe delay in the non-dispersive direction as well as resonant XES applications at normal incidence. However, the current capabilities of the Soft X-Ray (SXR) beamline at the LCLS do not produce the required energy range in a small enough sample footprint, hindering the single shot resonant XES application at SXR for chemical dynamics studies at surfaces. If an upgraded or future beamline at LCLS is developed with lower monochromator energy dispersion the width can be made small enough at the required energy range to be imaged by this spectrometer design.

  10. Ultrafast Dynamics of the VO2 Insulator-to-Metal Transition Observed by Nondegenerate Pump-Probe Spectroscopy

    Directory of Open Access Journals (Sweden)

    Haglund R. F.

    2013-03-01

    Full Text Available Non-degenerate pump (1.5 eV-probe (0.4 eV transmission spectroscopy on vanadium dioxide films grown on glass and three different sapphire substrates shows systematic variations with substrate that correlate with VO2 grain size and laser fluence. Temperature dependent measurements showed changes in the electronic response that is proportional to the metallic fraction.

  11. Femtosecond pump probe spectroscopy for the study of energy transfer of light-harvesting complexes from extractions of spinach leaves

    CSIR Research Space (South Africa)

    Ombinda-Lemboumba, Saturnin

    2009-09-01

    Full Text Available been implemented at the CSIR National Laser Centre and has been applied to investigate energy transfer processes in different parts of photosynthetic systems. In this paper, researchers report on the first results obtained with Malachite green as a...

  12. Pump--probe measurements of state-to-state rotational energy transfer rates in N2 (v=1)

    International Nuclear Information System (INIS)

    Sitz, G.O.; Farrow, R.L.

    1990-01-01

    We report direct measurements of the state-to-state rotational energy transfer rates for N 2 (υ=1) at 298 K. Stimulated Raman pumping of Q-branch (υ=1 left-arrow 0) transitions is used to prepare a selected rotational state of N 2 in the υ=1 state. After allowing an appropriate time interval for collisions to occur, 2+2 resonance-enhanced multiphoton ionization is used (through the a 1 Π g left-arrow X 1 Σ + g transition) to detect the relative population of the pumped level and other levels to which rotational energy transfer has occurred. We have performed a series of measurements in which a single even rotational level (J i =0--14) is excited and the time-dependent level populations are recorded at three or more delay times. This data set is then globally fit to determine the best set of state-to-state rate constants. The fitting procedure does not place any constraints (such as an exponential gap law) on the J or energy dependence of the rates. We compare our measurements and best-fit rates with results predicted from phenomenological rate models and from a semiclassical scattering calculation of Koszykowski et al. [J. Phys. Chem. 91, 41 (1987)]. Excellent agreement is obtained with two of the models and with the scattering calculation. We also test the validity of the energy-corrected sudden (ECS) scaling theory for N 2 by using our experimental transfer rates as basis rates (J=L→0), finding that the ECS scaling expressions accurately predict the remaining rates

  13. A new sample holder for laser-excited pump-probe magnetic measurements on a Focus photoelectron emission microscope

    International Nuclear Information System (INIS)

    Miguel, Jorge; Bernien, Matthias; Kuch, Wolfgang; Bayer, Daniela; Aeschlimann, Martin; Sanchez-Barriga, Jaime; Kronast, Florian; Duerr, Hermann A.

    2008-01-01

    A custom-made Omicron-compatible sample holder for time-resolved photoelectron emission microscopy experiments is presented. It comprises a sample plate with four contacts that hosts a chip carrier where the semiconductor substrate is mounted. Covering the sample holder, a 6 mm diameter mask protects electrostatically the sample from the extractor lens voltage while keeping the imaging quality unperturbed. The improvements are a greater sample lifetime and the ability to withstand much higher currents in the stripline that provides the magnetic pulse to the magnetic microstructure

  14. Real time observation of the excimer formation dynamics of a gas phase benzene dimer by picosecond pump-probe spectroscopy.

    Science.gov (United States)

    Miyazaki, Mitsuhiko; Fujii, Masaaki

    2015-10-21

    We observed the real-time excimer (EXC) formation dynamics of a gas phase benzene dimer (Bz2) cluster after photo-excitation to the S1 state by applying an ionization detected picosecond transient absorption method for probing the visible EXC absorption for the first time. The time evolution of the EXC absorption from the S1 0(0) level shows a rise that is well fitted by a single exponential function with a time constant of 18 ± 2 ps. The structure of the Bz dimer has a T-shaped structure in the ground electronic state, and that in the EXC state is a parallel sandwich (SW) structure. Thus, the observed rise time corresponds to the structural change from the T to the SW structures, which directly shows the EXC formation. On the other hand, the EXC formation after excitation of the S1 6(1) vibrational level of the stem site showed a faster rise of the time constant of 10 ± 2 ps. Supposing equilibrium between the EXC and the local excited states, it followed that the intramolecular vibrational energy redistribution rate of the 6(1) level is largely enhanced and becomes faster than the EXC formation reaction.

  15. Simulations of a FIR Oscillator with Large Slippage parameter at Jefferson Lab for FIR/UV pump-probe experiments

    International Nuclear Information System (INIS)

    Benson, Stephen V.; Campbell, L. T.; McNeil, B.W.T.; Neil, George R.; Shinn, Michelle D.; Williams, Gwyn P.

    2014-01-01

    We previously proposed a dual FEL configuration on the UV Demo FEL at Jefferson Lab that would allow simultaneous lasing at FIR and UV wavelengths. The FIR source would be an FEL oscillator with a short wiggler providing diffraction-limited pulses with pulse energy exceeding 50 microJoules, using the exhaust beam from a UVFEL as the input electron beam. Since the UV FEL requires very short pulses, the input to the FIR FEL is extremely short compared to a slippage length and the usual Slowly Varying Envelope Approximation (SVEA) does not apply. We use a non-SVEA code to simulate this system both with a small energy spread (UV laser off) and with large energy spread (UV laser on)

  16. Scientific horizons at the Institut Laue-Langevin

    Indian Academy of Sciences (India)

    The ongoing renewal programme has been directed to-wards renewing some of the neutron delivery systems – neutron guides and beam tubes – towards improvement of sample environment and installation of user-friendly data acquisition/handling systems, and in particular towards upgrading neutron instrumentation.

  17. Generation of femtosecond electron single pulse using laser photocathode RF gun

    Energy Technology Data Exchange (ETDEWEB)

    Uesaka, M.; Kinoshita, K.; Watanabe, T. [Nuclear Engineering Research Laboratory, University of Tokyo, Tokai, Ibaraki (JP)] [and others

    1998-11-01

    A new laser photocathode RF electron gun was installed in the second linac of the S-band twin linac system of Nuclear Engineering Research Laboratory(NERL) of University of Tokyo in August in 1997. Since then, the behavior of the new gun has been tested and the characteristic parameters have been evaluated. At the exit of the gun, the energy is 4.7 MeV, the charge per bunch 1 nC, the pulse width is 10 ps(FWHM), respectively, for 6 MW RF power supply from a klystron. The electron bunch is accelerated up to 17 MeV. The horizontal normalized emittance is 1 {pi} mm.mrad. Then, the bunch is compressed to be 440 fs(FWHM) with 0.35 nC by the chicane-type magnetic pulse compressor. The gun is planned to be used for femtosecond X-ray generation via the head-on Thomson scattering and laser wakefield acceleration in 1998. (author)

  18. Pressure Distribution on Inner Wall of Parabolic Nozzle in Laser Propulsion with Single Pulse

    Science.gov (United States)

    Cui, Cunyan; Hong, Yanji; Wen, Ming; Song, Junling; Fang, Juan

    2011-11-01

    A system based of dynamic pressure sensors was established to study the time resolved pressure distribution on the inner wall of a parabolic nozzle in laser propulsion. Dynamic calibration and static calibration of the test system were made and the results showed that frequency response was up to 412 kHz and linear error was less than 10%. Experimental model was a parabolic nozzle and three test points were preset along one generating line. This study showed that experimental results agreed well with those obtained by numerical calculation way in pressure evolution tendency. The peak value of the calculation was higher than that of the experiment at each tested orifice because of the limitation of the numerical models. The results of this study were very useful for analyzing the energy deposition in laser propulsion and modifying numerical models.

  19. Updating the induction module from single-pulse to double-pulses

    International Nuclear Information System (INIS)

    Huang Ziping; Wang Huacen; Deng Jianjun

    2002-01-01

    A double-pulse Linear Induced Accelerator (LIA) module is reconstructed based on a usual simple-pulse LIA module. By changing the length of one of the cables between the inductive cell and the Blumlein pulse forming line, two induction pulses with 90 ns FWHM and 150 kV pulse voltage are generated by the ferrite cores inductive cell. The interval time of the pulses is adjustable by changing the lengths of the cable

  20. Mechanism of single-pulse ablative generation of laser-induced periodic surface structures

    Czech Academy of Sciences Publication Activity Database

    Shugaev, M.V.; Gnilitskyi, I.; Bulgakova, Nadezhda M.; Zhigilei, L.

    2017-01-01

    Roč. 96, č. 20 (2017), s. 1-9, č. článku 205429. ISSN 2469-9950 R&D Projects: GA MŠk LO1602; GA ČR GA16-12960S; GA MŠk LM2015086 EU Projects: European Commission(XE) 739573 - HiLASE CoE Grant - others:OP VVV - HiLASE-CoE(XE) CZ.02.1.01/0.0/0.0/15_006/0000674 Institutional support: RVO:68378271 Keywords : molecular-dynamics simulations * metals * electron * spallation Subject RIV: BH - Optics, Masers, Lasers OBOR OECD: Optics (including laser optics and quantum optics) Impact factor: 3.836, year: 2016

  1. Transverse emittance measurement of high-current single pulse beams using pepper-pot method

    International Nuclear Information System (INIS)

    Ke Jianlin; Zhou Changgeng; Qiu Rui

    2013-01-01

    A pepper pot-imaging plate system has been developed and used to measure the 4-D transverse emittance of a vacuum arc ion source. Single beam pulses of tens to hundreds milliamperes were extracted from the plasma with 64 kV high voltage. An imaging plate was laid after the pepper pot to visualize the ion beamlets passing though the holes on the pepper pot. An application program was developed to show the phase-space distribution and calculate the ellipse and RMS emittances. The normalized RMS emittances are about 6.41 π·mm·mrad in x-direction and 4.61 π·mm·mrad in y-direction. It is shown that the emittance of the vacuum arc ion source is much larger than that of other types of ion sources, which is mainly attributed to the high current and the convex meniscus of this source. (authors)

  2. A Single Pulse Beam Emittance Measurement for the CERN Heavy Ion Linac

    CERN Document Server

    Crescenti, M

    1995-01-01

    A new device for transverse emittance measurement has been installed in the 4.2 MeV/u filter region of the CERN Heavy Ion Linac (Linac 3). It allows to obtain pulse-to-pulse (every 1.2 sec) visualisation of the Linac 3 beam parameters in order to tune the machine and to match the beam for injection into the first circular accelerator, the PS Booster. The system is based on the "multi-slit" technique similar to the well-known "pepper pot" method. A plate with a series of horizontal or vertical slits is placed in the beam, defining positions in the phase plane. Particles pass through the slits and drift to a scintillator screen where they produce light. The screen is looked at by an externally triggered high resolution CCD camera. For each slit position the light intensity distribution, in the limit of infinitesimal slit aperture, is proportional to the angle distribution of the particles and therefore, provides the angular distribution in the phase plane. The video signal from the camera is digitised and the r...

  3. Transcranial magnetic stimulation: no effect on mood with single pulse during learned helplessness.

    Science.gov (United States)

    Habel, U; Wild, B; Topka, H; Kircher, T; Salloum, J B; Schneider, F

    2001-04-01

    1. Transcranial Magnetic Stimulation (TMS) is suggested to be an effective tool in the treatment of depression. However, the methodology most suitable for clinical application remains unclear. 2. The effect of TMS was tested in a double-blind and placebo-controlled setting on 18 healthy subjects. At the same time an established learned helplessness paradigm was applied to induce dysphoria, which consisted of unsolvable anagrams. 3. Sixty 0.5 Hz stimuli were administered at an intensity of 130% of the subject's motor threshold after the subjects were exposed to the learned helplessness situation. Using a vertically positioned coil, the stimuli were applied to the right or to the left frontal cortex, or on the occipital cortex as a placebo condition. 4. Although dysphoria was successfully induced by unsolvable anagrams, TMS on either of the two frontal locations did not influence mood. This lack of effect may be due to the stimulation characteristics employed here (low TMS intensity, and low frequency). On the other hand, the findings may reflect the neurobiological difference between experimentally induced sad mood and clinical depression.

  4. Single-Pulse Dual-Energy Mammography Using a Binary Screen Coupled to Dual CCD Cameras

    Science.gov (United States)

    1999-08-01

    Fossum, "Active pixel sensors—Are CCD’s Dinosaurs ?," Proc. SPIE 1900, 2-14 (1993). "S. Mendis, S. E. Kemeny, R. Gee, B. Pain, and E. R. Fossum, "Progress...Clin Oncol 13:1470-1477, 1995 12. Wahl RL, Zasadny K, Helvie M, et al: Metabolic monitoring of breast cancer chemohormonotherapy using posi- tron

  5. Expansion-limited aggregation of nanoclusters in a single-pulse laser-produced plume

    International Nuclear Information System (INIS)

    Gamaly, E. G.; Madsen, N. R.; Rode, A. V.; Golberg, D.

    2009-01-01

    Formation of carbon nanoclusters in a single-laser-pulse created ablation plume was studied both in vacuum and in a noble gas environment at various pressures. The developed theory provides cluster radius dependence on combination of laser parameters, properties of ablated material, and type and pressure of an ambient gas in agreement with experiments. The experiments were performed on carbon nanoclusters formed by laser ablation of graphite targets with 12 picosecond 532 nm laser pulses at MHz-range repetition rate in a broad range of ambient He, Ar, Kr, and Xe gas pressures from 2x10 -2 to 1500 Torr. The experimental results confirmed our theoretical prediction that the average size of the nanoparticles depends weakly on the type of the ambient gas used, and is determined exclusively by the single laser pulse parameters even at the repetition rate as high as 28 MHz with the time gap 36 ns between the pulses. The most important finding relates to the fact that in vacuum the cluster size is mainly determined by hydrodynamic expansion of the plume while in the ambient gas it is controlled by atomic diffusion in the gas. We demonstrate that the ultrashort pulses can be used for production of clusters with the size less than the critical value, which separates the particles with properties drastically different from those of a material in a bulk. The presented results of experiments on formation of carbon nanoclusters are in close agreement with the theoretical scaling. The developed theory is applicable for cluster formation from any monatomic material, such as silicon for example.

  6. Single pulse two photon fluorescence lifetime imaging (SP-FLIM) with MHz pixel rate.

    Science.gov (United States)

    Eibl, Matthias; Karpf, Sebastian; Weng, Daniel; Hakert, Hubertus; Pfeiffer, Tom; Kolb, Jan Philip; Huber, Robert

    2017-07-01

    Two-photon-excited fluorescence lifetime imaging microscopy (FLIM) is a chemically specific 3-D sensing modality providing valuable information about the microstructure, composition and function of a sample. However, a more widespread application of this technique is hindered by the need for a sophisticated ultra-short pulse laser source and by speed limitations of current FLIM detection systems. To overcome these limitations, we combined a robust sub-nanosecond fiber laser as the excitation source with high analog bandwidth detection. Due to the long pulse length in our configuration, more fluorescence photons are generated per pulse, which allows us to derive the lifetime with a single excitation pulse only. In this paper, we show high quality FLIM images acquired at a pixel rate of 1 MHz. This approach is a promising candidate for an easy-to-use and benchtop FLIM system to make this technique available to a wider research community.

  7. X-ray topographic investigation of the deformation field around spots irradiated by FLASH single pulses

    Czech Academy of Sciences Publication Activity Database

    Wierzchowski, W.; Wieteska, K.; Balcer, T.; Klinger, D.; Sobierajski, R.; Zymierska, D.; Chalupský, Jaromír; Hájková, Věra; Burian, Tomáš; Gleeson, A.J.; Juha, Libor; Tiedtke, K.; Toleikis, S.; Vyšín, Luděk; Wabnitz, H.; Gaudin, J.

    2011-01-01

    Roč. 80, č. 10 (2011), s. 1036-1040 ISSN 0969-806X R&D Projects: GA AV ČR KAN300100702; GA MŠk LC510; GA ČR(CZ) GAP108/11/1312; GA MŠk(CZ) LC528; GA MŠk LA08024; GA AV ČR IAAX00100903; GA MŠk(CZ) ME10046 Institutional research plan: CEZ:AV0Z10100523 Keywords : silicon * FLASH irradiation * x-ray topography * deformation fields Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.227, year: 2011

  8. Absolute carrier phase effects in the two-color excitation of dipolar molecules

    International Nuclear Information System (INIS)

    Brown, Alex; Meath, W.J.; Kondo, A.E.

    2002-01-01

    The pump-probe excitation of a two-level dipolar (d≠0) molecule, where the pump frequency is tuned to the energy level separation while the probe frequency is extremely small, is examined theoretically as an example of absolute phase control of excitation processes. The state populations depend on the probe field's absolute carrier phase but are independent of the pump field's absolute carrier phase. Interestingly, the absolute phase effects occur for pulse durations much longer and field intensities much weaker than those required to see such effects in single pulse excitation

  9. Ultra-fast Movies Resolve Ultra-short Pulse Laser Ablation and Bump Formation on Thin Molybdenum Films

    Science.gov (United States)

    Domke, Matthias; Rapp, Stephan; Huber, Heinz

    For the monolithic serial interconnection of CIS thin film solar cells, 470 nm molybdenum films on glass substrates must be separated galvanically. The single pulse ablation with a 660 fs laser at a wavelength of 1053 nm is investigated in a fluence regime from 0.5 to 5.0 J/cm2. At fluences above 2.0 J/cm2 bump and jet formation can be observed that could be used for creating microstructures. For the investigation of the underlying mechanisms of the laser ablation process itself as well as of the bump or jet formation, pump probe microscopy is utilized to resolve the transient ablation behavior.

  10. Study of Carrier Dynamics in Self-Assembled InAs QDs and InAs/InGaSb Superlattices Using Pump Probe Spectroscopy

    National Research Council Canada - National Science Library

    Krishna, Sanjay

    2006-01-01

    .... The proposed duration of the project is three years. In this period (1 Jan 2003-31 Dec 2003), metamorphic InGaSb structures were grown and their optical and structural properties were characterized...

  11. Electron spin dynamics of Ce.sup.3+./sup. ions in YAG crystals studied by pulse-EPR and pump-probe Faraday rotation

    Czech Academy of Sciences Publication Activity Database

    Azamat, Dmitry; Belykh, V.V.; Yakovlev, D.R.; Fobbe, F.; Feng, D.H.; Evers, E.; Jastrabík, Lubomír; Dejneka, Alexandr; Bayer, M.

    2017-01-01

    Roč. 96, č. 7 (2017), s. 1-10, č. článku 075160. ISSN 2469-9950 R&D Projects: GA MŠk LO1409; GA ČR GA16-22092S Institutional support: RVO:68378271 Keywords : electron spin dynamics * Ce 3+ ions * YAG crystals * pulse-EPR * Faraday rotation Subject RIV: BM - Solid Matter Physics ; Magnetism OBOR OECD: Condensed matter physics (including formerly solid state physics, supercond.) Impact factor: 3.836, year: 2016

  12. Effect of an ultrafast laser induced plasma on a relativistic electron beam to determine temporal overlap in pump-probe experiments.

    Science.gov (United States)

    Scoby, Cheyne M; Li, R K; Musumeci, P

    2013-04-01

    In this paper we report on a simple and robust method to measure the absolute temporal overlap of the laser and the electron beam at the sample based on the effect of a laser induced plasma on the electron beam transverse distribution, successfully extending a similar method from keV to MeV electron beams. By pumping a standard copper TEM grid to form the plasma, we gain timing information independent of the sample under study. In experiments discussed here the optical delay to achieve temporal overlap between the pump electron beam and probe laser can be determined with ~1 ps precision. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Self-organization of single filaments and diffusive plasmas during a single pulse in dielectric-barrier discharges

    International Nuclear Information System (INIS)

    Babaeva, Natalia Yu; Kushner, Mark J

    2014-01-01

    Self-organization of filaments in dielectric-barrier discharges (DBDs) probably has many origins. However, the dominant cause is proposed to be the accumulation of charge on the surfaces of the bounding dielectrics that reinforces successive discharge pulses to occur at the same locations. A secondary cause is the electrostatic repulsion of individual plasma filaments. Self-organization typically develops over many discharge pulses. In this paper, we discuss the results of a computational investigation of plasma filaments in overvoltage DBDs that, under select conditions, display self-organized patterns (SOPs) of plasma density during a single discharge pulse. (Overvoltage refers to the rapid application of a voltage in excess of the quasi-dc breakdown voltage.) The origin of the SOPs is a synergistic relationship between the speed of the surface-ionization waves that propagate along each dielectric and the rate at which avalanche occurs across the gap. For our test conditions, SOPs were not observed at lower voltages and gradually formed at higher voltages. The same conditions that result in SOPs, i.e. the application of an overvoltage, also produce more diffuse discharges. A transition from a single narrow filament to a more diffuse structure was observed as overvoltage was approached. The sensitivity of SOPs to the orientation and permittivity of the bounding dielectrics is discussed. (paper)

  14. A new method for obtaining time resolved optical spectra of transients produced by a single pulse of electrons

    International Nuclear Information System (INIS)

    Gordon, S.; Schmidt, K.H.; Martin, J.E.

    1975-01-01

    The essential features of the kinetic spectroscopic method and the kinetic spectrophotometric method are summarized. It is stated that the new method embodies some of the advantages of both. A diagram of the apparatus is shown. This is essentially a version of a conventional pulse radiolysis experimental arrangement with the modification that the usual monochromator is replaced by a spectrograph equipped with a horizontal and a vertical slit and the usual photomultiplier-amplifier detector is replaced by a streak camera (TRW) incorporating an image converter tube (ICT) and a TV camera interfaced to a 2000 channel Biomation transient recorder. The time resolved absorption spectrum (or emission spectrum) is displayed on the P-11 phosphor of the ICT. This image is focussed on the photoelements of the TV tube. The TV camera scans the image of the spectrum stored on these elements and the output of this scan is stored in the Biomation. This recorder is in turn interfaced to a Sigma 5 computer. Results are presented for several experiments, from which it is concluded that with the present equipment absorbances down to 0.02 can be measured, and a time resolution of 1ns can be achieved. It is stated that with improved equipment it should be possible to extend the time resolution of the method to less than 50 picoseconds. (U.K.)

  15. Single-pulse measurement of density and temperature in a turbulent, supersonic flow using UV laser spectroscopy

    Science.gov (United States)

    Fletcher, D. G.; Mckenzie, R. L.

    1992-01-01

    Nonintrusive measurements of density and temperature and their turbulent fluctuation levels have been obtained in the boundary layer of an unseeded, Mach 2 wind tunnel flow. The spectroscopic technique that was used to make the measurements is based on the combination of laser-induced oxygen fluorescence and Raman scattering by oxygen and nitrogen from the same laser pulse. Results from this demonstration experiment compare favorably with previous measurements obtained in the same facility from conventional probes and an earlier spectroscopic technique.

  16. Time-resolved X-ray scattering program at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Rodricks, B.

    1994-01-01

    The Time-Resolved Scattering Program's goal is the development of instruments and techniques for time-resolved studies. This entails the development of wide bandpass and focusing optics, high-speed detectors, mechanical choppers, and components for the measurement and creation of changes in samples. Techniques being developed are pump-probe experiments, single-bunch scattering experiments, high-speed white and pink beam Laue scattering, and nanosecond to microsecond synchronization of instruments. This program will be carried out primarily from a white-beam, bend-magnet source, experimental station, 1-BM-B, that immediately follows the first optics enclosure (1-BM-A). This paper will describe the experimental station and instruments under development to carry out the program

  17. First results from the new reflectometer, D17B at the Institut Laue Langevin

    International Nuclear Information System (INIS)

    Cubitt, R.; Lauter, H.

    1999-01-01

    D17B will be a reflectometer with the maximum flexibility in resolution, methods of data acquisition and sample environment. The instrument will be able to cover a q-range of 0.001 to 0.4 A -1 and measure reflectivities of the order of 10 -8 . Due to the straightened guide and super-mirror focusing sections, the peak flux will be a factor of seven larger than D17. With a continuous source of neutrons such it is possible to measure reflectivity as a function of q using either a monochromatic beam or by time-of flight (TOF). D17B will have both these option available. The monochromatic method has the advantage of being able to utilize the peak wavelength flux at all points in the scan and is the most efficient method of dealing with polarising neutrons and spin-flipping for magnetic experiments. However the TOF method offers a greater flexibility of resolution and enables certain experiments like dynamics of fixed geometry to be carried out which are not possible with the monochromatic method. The detector will have an area of 250 x 500 mm with a resolution of 1.5 x 3 mm and will be able to be moved between 1 and 3.5 m from the sample position to enable a wide q-range of off-specular scattering to be detected. The reflection plane will be horizontal thus experiments involving free liquid surfaces will not be carried out in this instrument. Details of the present status of the instrument and first experimental results are presented. (author)

  18. A CZT high efficiency detector with 3D spatial resolution for Laue lens applications

    DEFF Research Database (Denmark)

    Auricchio, N.; Basili, A.; Caroli, E.

    2010-01-01

    For X- and γ-ray astronomy in the coming decades, both ESA and NASA have indicated in their guidelines the importance of developing innovative instrumentation operating in the hard X- and soft γ-ray range where important scientific issues are still open, exploiting high sensitivity (50–100 times ...

  19. Neutronics Conversion Analyses of the Laue-Langevin Institute (ILL) High Flux Reactor (RHF)

    Energy Technology Data Exchange (ETDEWEB)

    Bergeron, A. [Argonne National Lab. (ANL), Argonne, IL (United States); Dionne, B. [Argonne National Lab. (ANL), Argonne, IL (United States); Calzavara, Y. [Inst. Laue-Langevin (ILL), Grenoble (France)

    2014-09-30

    The following report describes the neutronics results obtained with the MCNP model of the RHF U7Mo LEU reference design that has been established in 2010 during the feasibility analysis. This work constitutes a complete and detailed neutronics analysis of that LEU design using models that have been significantly improved since 2010 and the release of the feasibility report. When possible, the credibility of the neutronics model is tested by comparing the HEU model results with experimental data or other codes calculations results. The results obtained with the LEU model are systematically compared to the HEU model. The changes applied to the neutronics model lead to better comparisons with experimental data or improved the calculation efficiency but do not challenge the conclusion of the feasibility analysis. If the U7Mo fuel is commercially available, not cost prohibitive, a back-end solution is established and if it is possible to manufacture the proposed element, neutronics analyses show that the performance of the reactor would not be challenged by the conversion to LEU fuel.

  20. Investigation of absorbed radiation dose in refraction-enhanced breast tomosynthesis by a Laue case analyser

    International Nuclear Information System (INIS)

    Sato, H.; Ando, M.; Shimao, D.

    2011-01-01

    An early diagnosis system for breast cancer using refraction-enhanced breast tomosynthesis is under development. Tomograms of breast specimens based on refraction-contrast were demonstrated using the simplest shift-and-add tomosynthesis algorithm. Raw projection image data of breast specimens for tomosynthesis were acquired for a total of 51 views over an angle of 50 deg., in increments of 1 deg., by rotating the object. The incident X ray was monochromatic synchrotron radiation with 20 keV. The purpose of this study was to estimate the absorbed dose of a new X-ray imaging method. As breast cancer almost always arises in glandular breast tissue, the average absorbed dose in such glandular tissue should be measured to estimate the radiation risk associated with mammography. The absorbed dose of the mammary gland due to monochromatic X rays was calculated by the Monte Carlo method, and the optimal X ray energy range for refraction-enhanced breast tomosynthesis was investigated through actual measurements. Compared with the conventional method, it was found to be below one-sixth per inspection. (authors)

  1. Complementary safety assessment in the light of the Fukushima accident - Laue Langevin Institute

    International Nuclear Information System (INIS)

    Desbriere; Caillot; Bidet

    2012-01-01

    This CSA (Complementary Safety Assessment) analyses the robustness of the Grenoble High Flux reactor to extreme situations such as those that led to the Fukushima accident and proposes a series of improvements. Robustness is the ability for the facility to withstand events beyond the level for which the facility was designed. Robustness is linked to safety margins but also to the situations leading to a sudden deterioration of the accident sequence (cliff edge effect). Safety is not only a matter of design or of engineered systems, it is also a matter of organization. So issues like crisis organization and work organization via subcontracting are also taken into consideration. This report is divided into 9 main chapters: 1) main features of the high flux reactor, 2) macroscopic study of safety, identification of structures and equipment essential to safety, 3) earthquake risk, 4) flood risk, 5) risks due to other extreme natural disasters, 6) the loss of electrical power supplies and of cooling systems, 7) management of severe accidents, 8) subcontracting policy, 9) synthesis and improvements. This study confirms the robustness of the facility and a series of improvements and modifications is proposed to face very unlikely situations (especially plurality of failures) that were not taken into account in baseline safety studies. (A.C.)

  2. Dynamics of Al/Fe{sub 2}O{sub 3} MIC combustion from short single-pulse photothermal initiation and time-resolved spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Stiegman, Albert E.; Park, Chi-Dong; Mileham, Melissa; Van de Burgt, Lambertus J. [Department of Chemistry and Biochemistry, Florida State University Tallahassee, FL (United States); Kramer, Michael P. [AFRL/MNME Eglin AFB, FL (United States)

    2009-08-15

    Time-resolved spectroscopy was used to study the dynamics of the photothermal ignition of Al/Fe{sub 2}O{sub 3} metastable intermolecular composites after single short-pulse laser initiation. The dynamics were recorded in several time domains from nanosecond to microsecond to quantify the dynamics from initial laser excitation to combustion. Time-averaged spectral data were also collected for the overall emission occurring during combustion. (Abstract Copyright [2009], Wiley Periodicals, Inc.)

  3. Reproducibility of Single-Pulse, Paired-Pulse, and Intermittent Theta-Burst TMS Measures in Healthy Aging, Type-2 Diabetes, and Alzheimer’s Disease

    Directory of Open Access Journals (Sweden)

    Peter J. Fried

    2017-08-01

    Full Text Available Background: Transcranial magnetic stimulation (TMS can be used to assess neurophysiology and the mechanisms of cortical brain plasticity in humans in vivo. As the use of these measures in specific populations (e.g., Alzheimer’s disease; AD increases, it is critical to understand their reproducibility (i.e., test–retest reliability in the populations of interest.Objective: Reproducibility of TMS measures was evaluated in older adults, including healthy, AD, and Type-2 diabetes mellitus (T2DM groups.Methods: Participants received two identical neurophysiological assessments within a year including motor thresholds, baseline motor evoked potentials (MEPs, short- and long-interval intracortical inhibition (SICI, LICI and intracortical facilitation (ICF, and MEP changes following intermittent theta-burst stimulation (iTBS. Cronbach’s α coefficients were calculated to assess reproducibility. Multiple linear regression analyses were used to investigate factors related to intraindividual variability.Results: Reproducibility was highest for motor thresholds, followed by baseline MEPs, SICI and LICI, and was lowest for ICF and iTBS aftereffects. The AD group tended to show higher reproducibility than T2DM or controls. Intraindividual variability of baseline MEPs was related to age and variability of RMT, while the intraindividual variability in post-iTBS measures was related to baseline MEP variability, intervisit duration, and Brain-derived neurotrophic factor (BDNF polymorphism.Conclusion: Increased reproducibility in AD may reflect pathophysiological declines in the efficacy of neuroplastic mechanisms. Reproducibility of iTBS aftereffects can be improved by keeping baseline MEPs consistent, controlling for BDNF genotype, and waiting at least a week between visits.Significance: These findings provide the first direct assessment of reproducibility of TMS measures in older clinical populations. Reproducibility coefficients may be used to adjust effect- and sample size calculations for future studies.

  4. Single-pulse terahertz coherent control of spin resonance in the canted antiferromagnet YFeO3, mediated by dielectric anisotropy

    DEFF Research Database (Denmark)

    Jin, Zuanming; Mics, Zoltán; Ma, Guohong

    2013-01-01

    We report on the coherent control of terahertz (THz) spin waves in a canted antiferromagnet yttrium orthoferrite, YFeO3, associated with a quasiferromagnetic (quasi-FM) spin resonance at a frequency of 0.3 THz, using a single-incident THz pulse. The spin resonance is excited impulsively by the ma...... polarization of the THz oscillation at the spin resonance frequency, suggests a key role of magnon–phonon coupling in spin-wave energy dissipation....

  5. Single pulsed-field magnetization on Gd-Ba-Cu-O Bulk HTS assembled for axial-gap type rotating machines

    International Nuclear Information System (INIS)

    Morita, E; Matsuzaki, H; Kimura, Y; Ohtani, I; Izumi, M; Nonaka, Y; Murakami, M; Ida, T; Sugimoto, H; Miki, M; Kitano, M

    2006-01-01

    We employed Gd-bulk HTS magnets as rotating poles for a smaller and lighter axial-gap type rotating machine. The bulk was placed between two vortex-type armature coils and cooled down to 77 K under zero-field. Pulsed current was applied to the vortex-type magnetizing coils. The trapped field distribution and transient flux behaviour strongly depend on the radial dimension of the armature vortex-type coil. In the present study, we show that there is an optimal radial dimension of magnetizing coils to the given bulk disk size to give a homogeneously conical distribution of the trapped flux

  6. Fabrication and characterization of homogeneous surface-enhanced Raman scattering substrates by single pulse UV-laser treatment of gold and silver films.

    Science.gov (United States)

    Christou, Konstantin; Knorr, Inga; Ihlemann, Jürgen; Wackerbarth, Hainer; Beushausen, Volker

    2010-12-07

    The fabrication of SERS-active substrates, which offer high enhancement factors as well as spatially homogeneous distribution of the enhancement, plays an important role in the expansion of surface-enhanced Raman scattering (SERS) spectroscopy to a powerful, quantitative, and noninvasive measurement technique for analytical applications. In this paper, a novel method for the fabrication of SERS-active substrates by laser treatment of 20, 40, and 60 nm thick gold and of 40 nm thick silver films supported on quartz glass is presented. Single 308 nm UV-laser pulses were applied to melt the thin gold and silver films. During the cooling process of the noble metal, particles were formed. The particle size and density were imaged by atomic force microscopy. By varying the fluence, the size of the particles can be controlled. The enhancement factors of the nanostructures were determined by recording self-assembled monolayers of benzenethiol. The intensity of the SERS signal from benzenethiol is correlated to the mean particle size and thus to the fluence. Enhancement factors up to 10(6) with a high reproducibility were reached. Finally we have analyzed the temperature dependence of the SERS effect by recording the intensity of benzenethiol vibrations from 300 to 120 K. The temperature dependence of the SERS effect is discussed with regard to the metal properties.

  7. Towards realistic laboratory simulation of high-energy-density events in planetary atmospheres: Using large laser sparks created by a single pulse of high-power lasers

    Czech Academy of Sciences Publication Activity Database

    Civiš, Svatopluk; Juha, Libor; Jehlička, J.

    2007-01-01

    Roč. 7, č. 3 (2007), s. 503-503 ISSN 1531-1074. [Bioastronomy 2007. 16.07.2007-20.07.2007, San Juach] R&D Projects: GA ČR GA203/06/1278; GA MŠk LC510; GA MŠk(CZ) LC528 Institutional research plan: CEZ:AV0Z40400503; CEZ:AV0Z10100520 Keywords : planetary atmospheres * high-power lasers Subject RIV: CF - Physical ; Theoretical Chemistry

  8. Max-von-Laue-lecture: Unmaking the bomb: A fissile material approach to nuclear disarmament and nonproliferation

    Energy Technology Data Exchange (ETDEWEB)

    Von Hippel, Frank N. [Princeton University, Princeton, NJ (United States)

    2015-07-01

    The number of operational nuclear weapons in the world has dropped from about 65,000 at the end of the Cold war to about 10,000 and can be driven much lower. But we have a huge amount of highly enriched uranium and separated plutonium from these dismantled Cold War nuclear weapons and from failed civilian plutonium breeder reactor commercialization programs. To make nuclear disarmament irreversible and prevent nuclear terrorism, all this material must be secured and disposed of. We also must abandon the idea of using a nuclear-weapon-usable material as a fuel * that is plutonium in power reactors and highly enriched uranium in naval-propulsion and research reactors. Fortunately, using plutonium as a fuel is uneconomic and research and naval reactors can be designed to use low-enriched uranium. Finally, we must move away from ambiguous national enrichment programs like Iran*s to multinational enrichment programs such as Urenco.

  9. X-ray convergent beam pattern simulation using the Moodie-Wagenfeld equations: 3-beam Laue case

    International Nuclear Information System (INIS)

    Liu, L.; Goodman, P.

    1998-01-01

    Pattern simulations for 3-beam X-ray diffraction are presented, by multi-slice calculations based on Moodie and Wagenfeld's formulation of the X-ray equations, which factorise Maxwell's equations into Dirac format, using circular-polarisation bases. The results are presented in the form of convergent-beam patterns for each diffraction order, using experience gained from CBED (convergent beam electron diffraction) and LACBED (large-angle CBED), since this displays the results in the most compact form. The acronym CBXRAD (convergent-beam X-ray-diffraction) is used for these patterns. Although optics required for the complete patterns is not currently available, capillary focussing is undergoing rapid development, and our simulations define critical angular ranges within reach of current designs. Simulations for light and heavy-atoms structures belonging to the enantiomorphic space-group pair P3 1 21 and P3 2 21, provide clear evidence of chiral interaction between radiation and structure, highlighting divergences from the well studied CBED pattern symmetries. MoKα 1 and TaKα 1 wavelengths were used to minimise absorption for the two structures respectively, although 'anomalous absorption' is always important due to the large thicknesses required (up to 20 mm)

  10. Separate visualization of endolymphatic space, perilymphatic space and bone by a single pulse sequence; 3D-inversion recovery imaging utilizing real reconstruction after intratympanic Gd-DTPA administration at 3 tesla

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Satake, Hiroko; Kawamura, Minako; Fukatsu, Hiroshi; Sone, Michihiko; Nakashima, Tsutomu

    2008-01-01

    Twenty-four hours after intratympanic administration of gadolinium contrast material (Gd), the Gd was distributed mainly in the perilymphatic space. Three-dimensional FLAIR can differentiate endolymphatic space from perilymphatic space, but not from surrounding bone. The purpose of this study was to evaluate whether 3D inversion-recovery turbo spin echo (3D-IR TSE) with real reconstruction could separate the signals of perilymphatic space (positive value), endolymphatic space (negative value) and bone (near zero) by setting the inversion time between the null point of Gd-containing perilymph fluid and that of the endolymph fluid without Gd. Thirteen patients with clinically suspected endolymphatic hydrops underwent intratympanic Gd injection and were scanned at 3 T. A 3D FLAIR and 3D-IR TSE with real reconstruction were obtained. In all patients, low signal of endolymphatic space in the labyrinth on 3D FLAIR was observed in the anatomically appropriate position, and it showed negative signal on 3D-IR TSE. The low signal area of surrounding bone on 3D FLAIR showed near zero signal on 3D-IR TSE. Gd-containing perilymphatic space showed high signal on 3D-IR TSE. In conclusion, by optimizing the inversion time, endolymphatic space, perilymphatic space and surrounding bone can be separately visualized on a single image using a 3D-IR TSE with real reconstruction. (orig.)

  11. Diffraction contrast as a sensitive indicator of femtosecond sub-nanoscale motion in ultrafast transmission electron microscopy

    Science.gov (United States)

    Cremons, Daniel R.; Schliep, Karl B.; Flannigan, David J.

    2013-09-01

    With ultrafast transmission electron microscopy (UTEM), access can be gained to the spatiotemporal scales required to directly visualize rapid, non-equilibrium structural dynamics of materials. This is achieved by operating a transmission electron microscope (TEM) in a stroboscopic pump-probe fashion by photoelectrically generating coherent, well-timed electron packets in the gun region of the TEM. These probe photoelectrons are accelerated down the TEM column where they travel through the specimen before reaching a standard, commercially-available CCD detector. A second laser pulse is used to excite (pump) the specimen in situ. Structural changes are visualized by varying the arrival time of the pump laser pulse relative to the probe electron packet at the specimen. Here, we discuss how ultrafast nanoscale motions of crystalline materials can be visualized and precisely quantified using diffraction contrast in UTEM. Because diffraction contrast sensitively depends upon both crystal lattice orientation as well as incoming electron wavevector, minor spatial/directional variations in either will produce dynamic and often complex patterns in real-space images. This is because sections of the crystalline material that satisfy the Laue conditions may be heterogeneously distributed such that electron scattering vectors vary over nanoscale regions. Thus, minor changes in either crystal grain orientation, as occurs during specimen tilting, warping, or anisotropic expansion, or in the electron wavevector result in dramatic changes in the observed diffraction contrast. In this way, dynamic contrast patterns observed in UTEM images can be used as sensitive indicators of ultrafast specimen motion. Further, these motions can be spatiotemporally mapped such that direction and amplitude can be determined.

  12. Ultra-fast movies of thin-film laser ablation

    Science.gov (United States)

    Domke, Matthias; Rapp, Stephan; Schmidt, Michael; Huber, Heinz P.

    2012-11-01

    Ultra-short-pulse laser irradiation of thin molybdenum films from the glass substrate side initiates an intact Mo disk lift off free from thermal effects. For the investigation of the underlying physical effects, ultra-fast pump-probe microscopy is used to produce stop-motion movies of the single-pulse ablation process, initiated by a 660-fs laser pulse. The ultra-fast dynamics in the femtosecond and picosecond ranges are captured by stroboscopic illumination of the sample with an optically delayed probe pulse of 510-fs duration. The nanosecond and microsecond delay ranges of the probe pulse are covered by an electronically triggered 600-ps laser. Thus, the setup enables an observation of general laser ablation processes from the femtosecond delay range up to the final state. A comparison of time- and space-resolved observations of film and glass substrate side irradiation of a 470-nm molybdenum layer reveals the driving mechanisms of the Mo disk lift off initiated by glass-side irradiation. Observations suggest that a phase explosion generates a liquid-gas mixture in the molybdenum/glass interface about 10 ps after the impact of the pump laser pulse. Then, a shock wave and gas expansion cause the molybdenum layer to bulge, while the enclosed liquid-gas mixture cools and condenses at delay times in the 100-ps range. The bulging continues for approximately 20 ns, when an intact Mo disk shears and lifts off at a velocity of above 70 m/s. As a result, the remaining hole is free from thermal effects.

  13. Light field driven streak-camera for single-shot measurements of the temporal profile of XUV-pulses from a free-electron laser; Lichtfeld getriebene Streak-Kamera zur Einzelschuss Zeitstrukturmessung der XUV-Pulse eines Freie-Elektronen Lasers

    Energy Technology Data Exchange (ETDEWEB)

    Fruehling, Ulrike

    2009-10-15

    The Free Electron Laser in Hamburg (FLASH) is a source for highly intense ultra short extreme ultraviolet (XUV) light pulses with pulse durations of a few femtoseconds. Due to the stochastic nature of the light generation scheme based on self amplified spontaneous emission (SASE), the duration and temporal profile of the XUV pulses fluctuate from shot to shot. In this thesis, a THz-field driven streak-camera capable of single pulse measurements of the XUV pulse-profile has been realized. In a first XUV-THz pump-probe experiment at FLASH, the XUV-pulses are overlapped in a gas target with synchronized THz-pulses generated by a new THz-undulator. The electromagnetic field of the THz light accelerates photoelectrons produced by the XUV-pulses with the resulting change of the photoelectron momenta depending on the phase of the THz field at the time of ionisation. This technique is intensively used in attosecond metrology where near infrared streaking fields are employed for the temporal characterisation of attosecond XUV-Pulses. Here, it is adapted for the analysis of pulse durations in the few femtosecond range by choosing a hundred times longer far infrared streaking wavelengths. Thus, the gap between conventional streak cameras with typical resolutions of hundreds of femtoseconds and techniques with attosecond resolution is filled. Using the THz-streak camera, the time dependent electric field of the THz-pulses was sampled in great detail while on the other hand the duration and even details of the time structure of the XUV-pulses were characterized. (orig.)

  14. Proposed ultraviolet free-electron laser at Brookhaven National Laboratory: A source for time-resolved biochemical spectroscopy

    International Nuclear Information System (INIS)

    Johnson, E.D.; Sutherland, J.C.; Laws, W.R.

    1992-01-01

    Brookhaven National Laboratory is designing an ultraviolet free- electron laser (UV-FEL) user facility that will provide pico-second and sub-picosecond pulses of coherent ultraviolet radiation for wavelengths from 300 to 75 nm. Pulse width will be variable from abut 7 ps to ∼ 200 fs, with repetition rates as high as 10 4 Hz, single pulse energies > 1 mJ and hence peak pulse power >200 MW and average beam power > 10 W. The facility will be capable of ''pump-probe'' experiments utilizing the FEL radiation with: (1) synchronized auxiliary lasers, (2) a second, independently tunable FEL beam, or (3) broad-spectrum, high-intensity x-rays from the adjacent National Synchrotron Light Source. The UV-FEL consists of a high repetition rate recirculating superconducting linear accelerator which feeds pulses of electrons to two magnetic wigglers. Within these two devices, photons from tunable ''conventional'' laser would be frequency multiplied and amplified. By synchronously tuning the seed laser and modulating the energy of the electron beam, tuning of as much as 60% in wavelength is possible between alternating pulses supplied to different experimental stations, with Fourier transform limited resolution. Thus, up to four independent experiments may operate at one time, each with independent control of the wavelength and pulse duration. The UV-FEL will make possible new avenues of inquiry in time studies of diverse field including chemical, surface, and solid state physics, biology and materials science. The experimental area is scheduled to include a station dedicated to biological research. The complement of experimental and support facilities required by the biology station will be determined by the interests of the user community. 7 refs., 5 figs

  15. Use of ultrafast dispersed pump-dump-probe and pump-repump-probe spectroscopies to explore the light-induced dynamics of peridinin in solution

    NARCIS (Netherlands)

    Papagiannakis, E.; Vengris, M.; Larsen, D.S.; van Stokkum, I.H.M.; Hiller, R.G.; van Grondelle, R.

    2006-01-01

    Optical pump-induced dynamics of the highly asymmetric carotenoid peridinin in methanol was studied by dispersed pump-probe, pump-dump-probe, and pump-repump-probe transient absorption spectroscopy in the visible region. Dispersed pump-probe measurements show that the decay of the initially excited

  16. An ultrafast study of Zinc Phthalocyanine in DMSO

    CSIR Research Space (South Africa)

    Ombinda-Lemboumba, Saturnin

    2010-10-01

    Full Text Available The ultrafast dynamics of Zinc Phthalocyanine was studied using trasient absorption pump probe spectroscopy. Zinc Phthalocyanine was excited (pumped) at 672nm and probed by a white light continuum. The pump-probe technique used in this study...

  17. Structure of magnesium selenate enneahydrate, MgSeO4·9H2O, from 5 to 250 K using neutron time-of-flight Laue diffraction.

    Science.gov (United States)

    Fortes, A Dominic; Alfè, Dario; Hernández, Eduardo R; Gutmann, Matthias J

    2015-06-01

    The complete structure of MgSeO4·9H2O has been refined from neutron single-crystal diffraction data obtained at 5, 100, 175 and 250 K. It is monoclinic, space group P2₁/c, Z = 4, with unit-cell parameters a = 7.222 (2), b = 10.484 (3), c = 17.327 (4) Å, β = 109.57 (2)°, and V = 1236.1 (6) Å(3) [ρ(calc) = 1770 (1) kg m(-3)] at 5 K. The structure consists of isolated [Mg(H2O)6](2+) octahedra, [SeO4](2-) tetrahedra and three interstitial lattice water molecules, all on sites of symmetry 1. The positions of the H atoms agree well with those inferred on the basis of geometrical considerations in the prior X-ray powder diffraction structure determination: no evidence of orientational disorder of the water molecules is apparent in the temperature range studied. Six of the nine water molecules are hydrogen bonded to one another to form a unique centrosymmetric dodecamer, (H2O)12. Raman spectra have been acquired in the range 170-4000 cm(-1) at 259 and 78 K; ab initio calculations, using density functional theory, have been carried out in order to aid in the analysis of the Raman spectrum as well as providing additional insights into the geometry and thermodynamics of the hydrogen bonds. Complementary information concerning the thermal expansion, crystal morphology and the solubility are also presented.

  18. Laser-Induced Damage with Femtosecond Pulses

    Science.gov (United States)

    Kafka, Kyle R. P.

    The strong electric fields of focused femtosecond laser pulses lead to non-equilibrium dynamics in materials, which, beyond a threshold intensity, causes laser-induced damage (LID). Such a strongly non-linear and non-perturbative process renders important LID observables like fluence and intensity thresholds and damage morphology (crater) extremely difficult to predict quantitatively. However, femtosecond LID carries a high degree of precision, which has been exploited in various micro/nano-machining and surface engineering applications, such as human eye surgery and super-hydrophobic surfaces. This dissertation presents an array of experimental studies which have measured the damage behavior of various materials under femtosecond irradiation. Precision experiments were performed to produce extreme spatio-temporal confinement of the femtosecond laser-solid damage interaction on monocrystalline Cu, which made possible the first successful direct-benchmarking of LID simulation with realistic damage craters. A technique was developed to produce laser-induced periodic surface structures (LIPSS) in a single pulse (typically a multi-pulse phenomenon), and was used to perform a pump-probe study which revealed asynchronous LIPSS formation on copper. Combined with 1-D calculations, this new experimental result suggests more drastic electron heating than expected. Few-cycle pulses were used to study the LID performance and morphology of commercial ultra-broadband optics, which had not been systematically studied before. With extensive surface analysis, various morphologies were observed, including LIPSS, swelling (blisters), simple craters, and even ring-shaped structures, which varied depending on the coating design, number of pulses, and air/vacuum test environment. Mechanisms leading to these morphologies are discussed, many of which are ultrafast in nature. The applied damage behavior of multi-layer dielectric mirrors was measured and compared between long pulse (150 ps

  19. Vibrational Energy Relaxation in Water-Acetonitrile Mixtures

    NARCIS (Netherlands)

    Cringus, Dan; Yeremenko, Sergey; Pshenichnikov, Maxim S.; Wiersma, Douwe A.; Kobayashi, Takayoshi; Kobayashi, Tetsuro; Nelson, Keith A.; Okada, Tadashi; Silvestri, Sandro De

    2004-01-01

    IR pump-probe spectroscopy is used to study the effect of hydrogen bonding on the vibrational energy relaxation pathways. Hydrogen bonding accelerates the population relaxation from 12ps in diluted acetonitrile solution to 700fs in bulk water.

  20. Ultrafast Non-thermal Response of Plasmonic Resonance in Gold Nanoantennas

    Science.gov (United States)

    Soavi, Giancarlo; Valle, Giuseppe Della; Biagioni, Paolo; Cattoni, Andrea; Longhi, Stefano; Cerullo, Giulio; Brida, Daniele

    Ultrafast thermalization of electrons in metal nanostructures is studied by means of pump-probe spectroscopy. We track in real-time the plasmon resonance evolution, providing a tool for understanding and controlling gold nanoantennas non-linear optical response.

  1. Dissociation dynamics of methylal

    Energy Technology Data Exchange (ETDEWEB)

    Beaud, P; Frey, H -M; Gerber, T; Mischler, B; Radi, P P; Tzannis, A -P [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1999-08-01

    The dissociation of methylal is investigated using mass spectrometry, combined with a pyrolytic radical source and femtosecond pump probe experiments. Based on preliminary results two reaction paths of methylal dissociation are proposed and discussed. (author) 4 fig., 3 refs.

  2. Development of Novel High Temperature Superconducting Detectors Based on Flux Activation and Ultrafast Dynamics

    National Research Council Canada - National Science Library

    Frankel, Anatoly

    1998-01-01

    It is proposed to study quasiparticle (QP) relaxation dynamics and flux mechanism of HTS using pump/probe femtosecond spectroscopy and nonequilibrium photoresponse in the presence of a magnetic field (and/or bias current...

  3. Measurements of gain and index dynamics in quantum dash semiconductor optical amplifiers

    DEFF Research Database (Denmark)

    Poel, Mike van der; Berg, Tommy Winther; Mørk, Jesper

    2004-01-01

    Ultrafast gain and index recovery of a 1.5um quantum dash amplifier after short pulse amplification is measured using pump-probe spectroscopy. The major part of the gain reduction is found to recover within a few picoseconds....

  4. Femtosecond Carrier Dynamics and Modelocking in Monolithic CPM Lasers. [SB1

    DEFF Research Database (Denmark)

    Brorson, S.D.; Bischoff, Svend; MØrk, J.

    1996-01-01

    Femtosecond pump-probe measurements of the dynamics in both forward- and reverse-biased semiconductor optical waveguides arepresented. Slow (nanosecond) as well as ultrafast (femtosecond) dynamics are observed in both kinds of structures....

  5. Ultra-Fast Low Energy Switching Using an InP Photonic Crystal H0 Nanocavity

    DEFF Research Database (Denmark)

    Yu, Yi; Palushani, Evarist; Heuck, Mikkel

    2013-01-01

    Pump-probe measurements on InP photonic crystal H0 nanocavities show large-contrast ultrafast switching at low pulse energy. For large pulse energies, high-frequency carrier density oscillations are induced, leading to pulsesplitting.......Pump-probe measurements on InP photonic crystal H0 nanocavities show large-contrast ultrafast switching at low pulse energy. For large pulse energies, high-frequency carrier density oscillations are induced, leading to pulsesplitting....

  6. Slide 24

    Indian Academy of Sciences (India)

    On one of the days many scientists were relaxing at a beach near Boston. Amongst those were some well-known ones, von Laue, Lawrence Bragg, Paul Ewald, Raman, Patterson, Hermann Mark, JD Bernal and others. A young lady with a camera rushed to get a photograph of von Laue wearing very brief swimming trunks.

  7. The discovery of X-ray diffraction by crystals and its great impact on science

    International Nuclear Information System (INIS)

    Mai Zhenhong

    2012-01-01

    In April 1912, Friedrich, Knipping and Laue discovered X-ray diffraction in a CuSO 4 crystal. Later, Laue derived the famous Laue equations which explain the diffraction phenomenon. For this, Laue was awarded a Nobel Prize for Physics in 1914. In 1912 W. H. Bragg and W. L. Bragg received news of Laue 's discovery, and from X-ray diffraction experiments in a ZnS crystal they derived the famous Bragg equation. For this work, father and son were together awarded the Nobel Prize for Physics in 1915, To commemorate the 100th anniversary of the discovery of X-ray diffraction, this article reviews the important contributions of the early pioneers and their historic impact on science and technology worldwide. (author)

  8. Gradients of geometrically necessary dislocations from white beam microdiffraction

    International Nuclear Information System (INIS)

    Barabash, R.I.; Ice, G.E.; Pang, J.W.L.

    2005-01-01

    Variations in the local crystallographic orientation due to the presence of geometrically necessary dislocations and dislocation boundaries smear the distribution of intensity near Laue reflections. Here, some simple model distributions of geometrically necessary dislocations, GNDs, are used to estimate the dislocation tensor field from the intensity distribution of Laue peaks. Streaking of the Laue spots is found to be quantitatively and qualitatively distinct depending on the ratio between the absorption coefficient and the GND density gradient. In addition, different slip systems cause distinctly different Laue-pattern streaking. Experimental Laue patterns are therefore sensitive to stored dislocations and GNDs. As an example, white beam microdiffraction was applied to characterize the dislocation arrangement in a deformed polycrystalline Ni grain during in situ uniaxial tension

  9. Locking Lasers to RF in an Ultrafast FEL

    International Nuclear Information System (INIS)

    Wilcox, R.; Huang, G.; Doolittle, L.; White, W.; Frisch, J.; Coffee, R.

    2010-01-01

    Using a novel, phase-stabilized RF-over-fiber scheme, they transmit 3GHz over 300m with 27fs RMS error in 250kHz bandwidth over 12 hours, and phase lock a laser to enable ultrafast pump-probe experiments. Free-electron lasers (FELs) are capable of producing short-duration (< 10fs), high-energy X-ray pulses for a range of scientific applications. The recently activated Linac Coherent Light Source (LCLS) FEL facility at SLAC will support experiments which require synchronized light pulses for pump-probe schemes. They developed and operated a fiber optic RF transmission system to synchronize lasers to the emitted X-ray pulses, which was used to enable the first pump-probe experiments at the LCLS.

  10. Optical spin generation/detection and spin transport lifetimes

    International Nuclear Information System (INIS)

    Miah, M. Idrish

    2011-01-01

    We generate electron spins in semiconductors by optical pumping. The detection of them is also performed by optical technique using time-resolved pump-probe photoluminescence polarization measurements in the presence of an external magnetic field perpendicular to the generated spin. The spin polarization in dependences of the pulse length, pump-probe delay and external magnetic field is studied. From the dependence of spin-polarization on the delay of the probe, the electronic spin transport lifetimes and the spin relaxation frequencies as a function of the strength of the magnetic field are estimated. The results are discussed based on hyperfine effects for interacting electrons.

  11. Optical spin generation/detection and spin transport lifetimes

    Energy Technology Data Exchange (ETDEWEB)

    Miah, M. Idrish, E-mail: m.miah@griffith.edu.au [Department of Physics, University of Chittagong, Chittagong 4331 (Bangladesh)

    2011-02-25

    We generate electron spins in semiconductors by optical pumping. The detection of them is also performed by optical technique using time-resolved pump-probe photoluminescence polarization measurements in the presence of an external magnetic field perpendicular to the generated spin. The spin polarization in dependences of the pulse length, pump-probe delay and external magnetic field is studied. From the dependence of spin-polarization on the delay of the probe, the electronic spin transport lifetimes and the spin relaxation frequencies as a function of the strength of the magnetic field are estimated. The results are discussed based on hyperfine effects for interacting electrons.

  12. Saturation broadening effect in an InP photonic-crystal nanocavity switch

    DEFF Research Database (Denmark)

    Yu, Yi; Palushani, Evarist; Heuck, Mikkel

    2014-01-01

    Pump-probe measurements on InP photonic-crystal nanocavities show large-contrast fast switching at low pulse energy. For large pulse energies, large resonance shifts passing across the probe lead to switching contrast saturation and switching time-window broadening. © 2014 OSA.......Pump-probe measurements on InP photonic-crystal nanocavities show large-contrast fast switching at low pulse energy. For large pulse energies, large resonance shifts passing across the probe lead to switching contrast saturation and switching time-window broadening. © 2014 OSA....

  13. Absorption anisotropy studies of polymethine dyes

    International Nuclear Information System (INIS)

    Lepkowicz, Richard S.; Cirloganu, Claudiu M.; Przhonska, Olga V.; Hagan, David J.; Van Stryland, Eric W.; Bondar, Mikhail V.; Slominsky, Yuriy L.; Kachkovski, Alexei D.; Mayboroda, Elena I.

    2004-01-01

    The determination of the spectral position of the excited states and orientation of the transition dipole moments of polymethine molecules is experimentally measured using two methods: the steady-state fluorescence anisotropy method, and a two-color polarization-resolved pump-probe method. This novel use of the pump-probe method is described in detail and a comparison to the fluorescence method is given. Quantum-chemical modeling on the effects of the bridge structure in the polymethine chromophore on the linear absorption spectrum is also discussed

  14. The strange rays of Professor Roentgen; Les etranges rayons du Professeur Roentgen

    Energy Technology Data Exchange (ETDEWEB)

    Guinier, A. [Paris-11 Univ., 91 - Orsay (France)

    1995-12-31

    This paper relates the historical discovery of X radiations in 1895 by the German Physicist Wilhelm Conrad Roendgen in his laboratory of Wurzburg University. Independently of Roendgen, several physicists such as Charles Glover Barkla, Jean Perrin or Max von Laue have tried to determine the nature of X rays. In 1912, in Cambridge (UK) William Henry and William Lawrence Bragg have used the X-ray diffraction property, discovered by Laue`s team, to explore the atomic structure of crystals. The recent development of computers technology has considerably increased the automation of data collection and the analysis of complex diffraction diagrams. (J.S.). 3 refs., 3 photos.

  15. Prospects For Gamma-ray Focusing Telescopes Beyond 70/100 Kev

    Science.gov (United States)

    Frontera, F.

    2011-09-01

    I will report on the LAUE project, devoted to the development of a lens petal with 20 m focal length. The final goal is to develop a technology for building Laue lenses with a passband from 70/100 to 600 keV. The project is on the way in a synergic collaboration between scientific institutions (University of Ferrara; INAF/IASF, Bologna; CNR/IMEM, Parma; DTM, Modena; Thales-Alenia Space Italy). The LAUE project is supported by the Italian Space Agency ASI.

  16. Femtosecond water dynamics in reverse-micellar nanodroplets

    NARCIS (Netherlands)

    Cringus, D; Lindner, J; Milder, MTW; Pshenichnikov, MS; Vohringer, P; Wiersma, DA; Milder, Maaike T.W.; Pshenichnikov, Maxim S.; Vöhringer, Peter

    2005-01-01

    Vibrational energy relaxation and ultrafast thermalization following impulsive excitation of the OH-stretching band of water nanodroplets confined to reverse micelles is studied by infrared pump-probe spectroscopy with sub-100 fs time resolution. The self-consistent analysis of experimental data for

  17. Vibrational dynamics of ice in reverse micelles

    NARCIS (Netherlands)

    Dokter, A.M.; Petersen, C.; Woutersen, S.; Bakker, H.J.

    2008-01-01

    he ultrafast vibrational dynamics of HDO:D2O ice at 180 K in anionic reverse micelles is studied by midinfrared femtosecond pump-probe spectroscopy. Solutions containing reverse micelles are cooled to low temperatures by a fast-freezing procedure. The heating dynamics of the micellar solutions is

  18. Self-trapped states in proteins?

    NARCIS (Netherlands)

    Austin, R. H.; Xie, A. H.; van der Meer, L.; Shinn, M.; Neil, G.

    2003-01-01

    We show here that the temperature dependence of the amide I band of myoglobin shows evidence for a low-lying S-elf-trapped state at 6.15 mum. We have conducted a careful set of picosecond pump-probe experiments providing results as a function of temperature. and wavelength and show that this

  19. Journal of Chemical Sciences | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    Picosecond pump-probe investigations confirm that the photoinduced electron transfer occurs from the surfaceadsorbed phenosafranine in the excited state to the nickel(II) complex within zeolite-Y cavity and also to the Ni(bpy) 3 2 + complex in contact with the phenosafranine dye co-adsorbed on the external surface of the ...

  20. Triplet State Resonance Raman Spectrum of all-trans-diphenylbutadiene

    DEFF Research Database (Denmark)

    Wilbrandt, Robert Walter; Grossman, W.E.L.; Killough, P.M

    1984-01-01

    The resonance Raman spectrum of all-trans-diphenylbutadiene (DPB) in its ground state and the resonance Raman spectrum (RRS) of DPB in its short-lived electronically excited triplet state are reported. Transient spectra were obtained by a pump-probe technique using two pulsed lasers...

  1. Architecture and dynamics of proteins and aqueous solvation complexes

    NARCIS (Netherlands)

    Lotze, S.M.

    2015-01-01

    For this thesis, the molecular dynamics of water and biological (model) systems have been studied with advanced nonlinear optical techniques. In chapters 4-5, the technique of femtosecond mid-infrared pump probe spectroscopy has been used to study the energy transfer and the reorientational dynamics

  2. Excited-state intramolecular hydrogen transfer (ESIHT) of 1,8-Dihydroxy-9,10-anthraquinone (DHAQ) characterized by ultrafast electronic and vibrational spectroscopy and computational modeling

    KAUST Repository

    Mohammed, Omar F.; Xiao, Dequan; Batista, Victor S.; Nibbering, Erik Theodorus Johannes

    2014-01-01

    of femtosecond UV/vis and UV/IR pump-probe spectroscopic data. Upon photoabsorption at 400 nm, the S 2 electronic excited state is initially populated, followed by a rapid equilibration within 150 fs through population transfer to the S 1 state where DHAQ

  3. Identifying the role of the local density of optical states in frequency conversion of light in confined media

    NARCIS (Netherlands)

    Yuce, E.; Ctistis, Georgios; Claudon, J.; Gerard, J.M.; Vos, Willem L.

    2014-01-01

    We have reversibly switched the resonance of a GaAs-AlAs microcavity in the near-infrared near λ=1300 nm within 300 fs by the electronic Kerr effect. We reveal by pump-probe spectroscopy a remarkable red shift or blue shift of the light confined inside the cavity for small pulse delays, depending on

  4. TIME-RESOLVED INFRARED SPECTROSCOPY IN THE U121R BEAMLINE AT THE NSLS

    International Nuclear Information System (INIS)

    CARR, G.L.; LAVEIGNE, J.D.; LOBO, R.P.S.M.; REITZE, D.H.; TANNER, D.B.

    1999-01-01

    A facility for performing time-resolved infrared spectroscopy has been developed at the NSLS, primarily at beamline U12IR. The pulsed IR light from the synchrotron is used to perform pump-probe spectroscopy. The authors present here a description of the facility and results for the relaxation of photoexcitations in both a semiconductor and superconductor

  5. Ultrafast quasiparticle dynamics of FeTe0.75Se0.25 superconductor

    Directory of Open Access Journals (Sweden)

    Katagiri T.

    2013-03-01

    Full Text Available The electron-phonon coupling constant (λ≈0.45 obtained from femtosecond pump-probe reflection measurements suggests that a phonon-mediated process cannot be the dominant mechanism for superconductivity of FeTe0.75Se0.25.

  6. Fulltext PDF

    Indian Academy of Sciences (India)

    The excitation scheme thus consists of two simultaneous Λ resonances, i.e., a double Λ resonance. [6–8], coupled by a strong pump and a weak probe. Such a study has a very direct bearing on pump-probe coherent spectroscopy experiments in alkali atoms, where the excited hyperfine levels are relatively closely spaced.

  7. Coherent amplitudon generation in blue bronze through ultrafast interband quasi-particle decay

    NARCIS (Netherlands)

    Sagar, Dodderi M.; Tsvetkov, Artem A.; Fausti, Daniele; van Smaalen, Sander; van Loosdrecht, Paul H. M.

    2007-01-01

    The charge density wave system K(0.3)MoO(3) has been studied using variable pulse energy pump-probe spectroscopy, ellipsometry, and inelastic light scattering. The observed transient reflectivity response exhibits quite a complex behaviour, containing contributions due to quasi-particle excitations,

  8. Switching characteristics of an InP photonic crystal nanocavity: Experiment and theory

    DEFF Research Database (Denmark)

    Yu, Yi; Palushani, Evarist; Heuck, Mikkel

    2013-01-01

    The dynamical properties of an InP photonic crystal nanocavity are experimentally investigated using pump-probe techniques and compared to simulations based on coupled-mode theory. Excellent agreement between experimental results and simulations is obtained when employing a rate equation model...

  9. Exciton modeling of energy-transfer dynamics in the LHCII complex of higher plants: a Redfield theory approach

    NARCIS (Netherlands)

    Novoderezhkin, V.; Salverda, J.M.; Amerongen, van H.; Grondelle, van R.

    2003-01-01

    We propose an exciton model for the peripheral plant light-harvesting complex LHCII that allows us to explain the absorption (OD) and linear dichroism (LD) spectra, the superradiance (SR), the pump-probe transient absorption (TA), the three-pulse photon echo peak shift (3PEPS), and transient grating

  10. Exciton modeling of energy-transfer dynamics in the LHCII complex of higher plants: A redfield theory approach

    NARCIS (Netherlands)

    Novoderezhkin, V.; Salverda, J.M.; van Amerongen, H.; van Grondelle, R.

    2003-01-01

    We propose an exciton model for the peripheral plant light-harvesting complex LHCII that allows us to explain the absorption (OD) and linear dichroism (LD) spectra, the superradiance (SR), the pump-probe transient absorption (TA), the three-pulse photon echo peak shift (3PEPS), and transient grating

  11. Refresher Course on Lasers and Applications in Chemical Processes

    Indian Academy of Sciences (India)

    lasers, modes of laser, mode locking, Q-switching, nonlinear optical materials, electro- optic and magneto-optic materials. It will also include laboratory demonstration experi- ments in selected areas of fluorescence and pump-probe methods. Teachers who wish to participate in the Refresher Course should submit their brief.

  12. Nonlinear dynamics of semiconductors in strong THz electric fields

    DEFF Research Database (Denmark)

    Tarekegne, Abebe Tilahun

    In this thesis, we investigate nonlinear interactions of an intense terahertz (THz) field with semiconductors, in particular the technologically relevant materials silicon and silicon carbide. We reveal the time-resolved dynamics of the nonlinear processes by pump-probe experiments that involve...

  13. Selective Coherent Excitation of Charged Density Waves

    NARCIS (Netherlands)

    Tsvetkov, A.A.; Sagar, D.M.; Loosdrecht, P.H.M. van; Marel, D. van der

    2003-01-01

    Real time femtosecond pump-probe spectroscopy is used to study collective and single particle excitations in the charge density wave state of the quasi-1D metal, blue bronze. Along with the previously observed collective amplitudon excitation, the spectra show several additional coherent features.

  14. Theory of laser-assisted autoionization by attosecond light pulses

    International Nuclear Information System (INIS)

    Zhao, Z.X.; Lin, C.D.

    2005-01-01

    We present a quantum theory of the decay of an autoionizing state created in the attosecond xuv (extreme ultraviolet) pump and laser probe measurements within the strong field approximation employing resonance parameters from Fano's theory. From the electron spectra versus the pump-probe time delay, we show how the lifetimes of the resonances can be extracted directly from the time domain measurements

  15. Photoisomerization and Photoionization of the photoactive yellow protein chromophore in solution.

    NARCIS (Netherlands)

    Larsen, D.S.; Vengris, M.; van Stokkum, I.H.M.; van der Horst, M.A.; de Weerd, F.; Hellingwerf, K.J.; van Grondelle, R.

    2004-01-01

    Dispersed pump-dump-probe spectroscopy has the ability to characterize and identify the underlying ultrafast dynamical processes in complicated chemical and biological systems. This technique builds on traditional pump-probe techniques by exploring both ground- and excited-state dynamics and

  16. Ultrafast dynamics of isolated model photoactive yellow protein chromophores: "Chemical perturbation theory" in the laboratory

    NARCIS (Netherlands)

    Vengris, M.; Larsen, D.S.; van der Horst, M.A.; Larsen, O.F.A.; Hellingwerf, K.J.; van Grondelle, R.

    2005-01-01

    Pump-probe and pump-dump probe experiments have been performed on several isolated model chromophores of the photoactive yellow protein (PYP). The observed transient absorption spectra are discussed in terms of the spectral signatures ascribed to solvation, excited-state twisting, and vibrational

  17. Elastic modulus of Extreme Ultraviolet exposed single-layer graphene

    NARCIS (Netherlands)

    Mund, Baibhav Kumar; Gao, An; Sturm, Jacobus Marinus; Lee, Christopher James; Bijkerk, Frederik

    2015-01-01

    Highly transparent membranes are required for a number of applications, such as protective coatings for components in Extreme Ultraviolet (EUV) lithography, beam splitters (EUV pump-probe experiments), transmission gratings, and reticles. Graphene is an excellent candidate due to its high tensile

  18. Tilting after Dutch windmills: probably no long-lived Davydov solitons in proteins

    NARCIS (Netherlands)

    Austin, R. H.; Xie, A. H.; Fu, D.; Warren, W.; Redlich, B.; van der Meer, L.

    2009-01-01

    We present a summary of picosecond pump-probe and photon echo experiments in the mid-IR at 6 mu m on the protein myoglobin. The intriguing temperature dependence of the amide I band in Mb is rather similar to the temperature dependence of the amide I band of acetanilide, the molecule that launched

  19. Switching dynamics in InP photonic-crystal nanocavity

    DEFF Research Database (Denmark)

    Yu, Yi; Palushani, Evarist; Heuck, Mikkel

    2016-01-01

    In this paper, we presented switching dynamic investigations on an InP photonic-crystal (PhC) nanocavity structure using homodyne pump-probe measurements. The measurements were compared with simulations based on temporal nonlinear coupled mode theory and carrier rate equations for the dynamics of...

  20. Optical Properties and Lasing in GaN

    National Research Council Canada - National Science Library

    Song, J

    2001-01-01

    .... In the second article. femtosecond pump-probe transmission spectroscopy was used to study the nonequilibrium carrier dynamics in a GaN thin film at 10 K with carrier densities ranging from 4 x 10(exp 17) to 10(exp 19)/cu cm...

  1. Ultrafast Non-Thermal Electron Dynamics in Single Layer Graphene

    Directory of Open Access Journals (Sweden)

    Novoselov K.S.

    2013-03-01

    Full Text Available We study the ultrafast dynamics of non-thermal electron relaxation in graphene upon impulsive excitation. The 10-fs resolution two color pump-probe allows us to unveil the non-equilibrium electron gas decay at early times.

  2. Gas-Phase Excited State Dynamics of Bithiophenes

    DEFF Research Database (Denmark)

    Skov, Anders Bo; Baldtzer Liisberg, Mikkel; Bjørnholst, Martin Alex

    Ved hjælp af pump-probe spektroskopi undersøges de exciterede tilstandes dynamik af forskellige modelsystemer af polythiophen-polymerer til brug i solceller. Resultaterne viser at langt-levede, nyttige tilstande opstår allerede ved bithiophen-niveau, mens at thiophen og dimethylthiophen er dårlige...

  3. Exciton dynamics in GaAs/AlxGa1-xAs quantum wells

    DEFF Research Database (Denmark)

    Litvinenko, K.; Birkedal, Dan; Lyssenko, V. G.

    1999-01-01

    The changes induced in the optical absorption spectrum of a GaAs/AlxGa1-xAs multiple quantum well due to a photoexcited carrier distribution are reexamined. We use a femtosecond pump-probe technique to excite excitons and free electron-hole pairs. We find that for densities up to 10(11) cm(-2...

  4. Exciplex-exciplex energy transfer and annihilation in solid films of porphyrin-fullerene dyads

    NARCIS (Netherlands)

    Lehtivuori, Heli; Lemmetyinen, Helge; Tkachenko, Nikolai V.

    2006-01-01

    Exciplex-exciplex annihilation was observed for the first time in porphyrin-fullerene molecular films. The films were prepared using Langmuir-Blodgett and drop casting methods. The exciplex-exciplex interactions were studied using femtosecond pump-probe method. The exciplex-exciplex annihilation can

  5. Distributed decay kinetics of charge separated state in solid film

    NARCIS (Netherlands)

    Lehtivuori, Heli; Efimov, Alexander; Lemmetyinen, Helge; Tkachenko, Nikolai V.

    2007-01-01

    Photoinduced electron transfer in solid films of porphyrin-fullerene dyads was studied using femtosecond pump-probe method. The relaxation of the main photo-product, intramolecular exciplex, was found to be essentially non-exponential. To analyze the decays a model accounting for a distribution of

  6. Femtosecond spectroscopic study of the solvation of amphiphilic molecules by water

    NARCIS (Netherlands)

    Rezus, Y.L.A.; Bakker, H.J.

    2008-01-01

    We use polarization-resolved mid-infrared pump-probe spectroscopy to study the aqueous solvation of proline and N-methylacetamide. These molecules serve as models to study the solvation of proteins. We monitor the orientational dynamics of partly deuterated water molecules (HDO) that are present at

  7. Effect of Isomerization on Excited-State Dynamics of Carotenoid Fucoxanthin

    Czech Academy of Sciences Publication Activity Database

    Kuznetsova, V.; Chábera, P.; Litvín, Radek; Polívka, Tomáš; Fuciman, M.

    2017-01-01

    Roč. 121, č. 17 (2017), s. 4438-4447 ISSN 1520-6106 Institutional support: RVO:60077344 Keywords : charge-transfer state * light-harvesting complex * pump-probe spectroscopy * ultrafast dynamics Subject RIV: BO - Biophysics OBOR OECD: Biophysics Impact factor: 3.177, year: 2016

  8. Gain dynamics in p-doped InGaAs quantum dot amplifiers from room to cryogenic temperatures

    NARCIS (Netherlands)

    Borri, P.; Cesaria, V.; Rossetti, M.; Fiore, A.; Langbein, W.

    2009-01-01

    We have compared the gain dynamics of the ground state excitonic transition between undoped and p-doped electrically-pumped InGaAs quantum-dot optical amplifiers, for temperatures from 300K to 20K. A pump-probe differential transmission technique in heterodyne detection with sub-picosecond time

  9. A transient absorption study of allophycocyanin

    Indian Academy of Sciences (India)

    Transient dynamics of allophycocyanin trimers and monomers are observed by using the pump-probe, transient absorption technique. The origin of spectral components of the transient absorption spectra is discussed in terms of both kinetics and spectroscopy. We find that the energy gap between the ground and excited ...

  10. A Cherenkov radiator for FEL-synchronized VUV-pulses at a linac-based FEL

    NARCIS (Netherlands)

    Goloviznin, V. V.; Oepts, D.; van der Wiel, M. J.

    1997-01-01

    A possible way to carry out two-color IR+VUV pump-probe experiments at linac-based FELs is proposed. The idea is to supply an FEL facility with a gas cell filled with helium or hydrogen, so that the electron beam, upon passage through the undulator, could be used to generate ultraviolet Cherenkov

  11. A Cherenkov radiator for FEL-synchronized VUV-pulses at a linac-based FEL

    NARCIS (Netherlands)

    Goloviznin, V.V.; Oepts, W.; Wiel, van der M.J.

    1997-01-01

    A possible way to carry out two-color IR + VUV pump-probe experiments at linac-based FELs is proposed. The idea is to supply an FEL facility with a gas cell filled with helium or hydrogen, so that the electron beam, upon passage through the undulator, could be used to generate ultraviolet Cherenkov

  12. Probing spin-vibronic dynamics using femtosecond X-ray spectroscopy

    DEFF Research Database (Denmark)

    Penfold, T. J.; Pápai, Mátyás Imre; Rozgonyi, T.

    2016-01-01

    Ultrafast pump-probe spectroscopy within the X-ray regime is now possible owing to the development of X-ray Free Electrons Lasers (X-FELs) and is opening new opportunities for the direct probing of femtosecond evolution of the nuclei, the electronic and spin degrees of freedom. In this contributi...

  13. Imaging Molecular Structure through Femtosecond Photoelectron Diffraction on Aligned and Oriented Gas-Phase Molecules

    DEFF Research Database (Denmark)

    Boll, Rebecca; Rouzee, Arnaud; Adolph, Marcus

    2014-01-01

    This paper gives an account of our progress towards performing femtosecond time-resolved photoelectron diffraction on gas-phase molecules in a pump-probe setup combining optical lasers and an X-ray Free-Electron Laser. We present results of two experiments aimed at measuring photoelectron angular...

  14. Absorption coefficient of nearly transparent liquids measured using thermal lens spectrometry

    Directory of Open Access Journals (Sweden)

    H.Cabrera

    2006-01-01

    Full Text Available We use an optimized pump-probe mode-mismatched thermal lens scheme to determine the optical absorption coefficient and thermal diffusivity of ethanol, benzene, acetone, methanol, toluene and chloroform. In this scheme the excitation beam is focused in the presence of a collimated probe beam. The agreement between experimentally obtained results and values reported in the literature is good.

  15. Conductivity of strongly pumped superconductors. An electron-phonon system far from equilibrium

    Energy Technology Data Exchange (ETDEWEB)

    Krull, Holger

    2015-01-29

    The study of nonequilibrium physics is of great interest, because one can capture novel phenomena and properties which are hidden at equilibrium, e.g., one can study relaxation processes. A common way to study the nonequilibrium dynamics of a sample is a pump-probe experiment. In a pump probe experiment an intense laser pulse, the so called pump pulse, excites the sample and takes it out of equilibrium. After a certain delay time a second pulse, the probe pulse, measures the actual state of the sample. In this thesis, we theoretically study the pump-probe response of superconductors. On the one hand we are interest in the effect of a pump pulse and on the other hand we want to provide the pump-probe response, such that experimental measurement can be easily interpreted. In order to do this, we use the density matrix formalism to compute the pump-probe response of the system. In the density matrix formalism equations of motion are set up for expectation values of interest. In order to study the dynamics induced by a pump pulse, we compute the temporal evolution of the quasiparticle densities and the mean phonon amplitude. We find that the induced dynamics of the system depends on characteristics of the pump pulse. For short pulses, the system is pushed into the nonadiabatic regime. In this regime, the order parameter is lowered during the pump pulse and shows a 1/(√(t))-decaying oscillation afterwards. In addition, coherent phonons are generated, which is resonantly enhanced if the frequency of the order parameter oscillation is equal to the phonon frequency. For long pulses, the system is pushed into the adiabatic regime. In this regime, the order parameter is lowered during the pulse and remains almost constant afterwards. Further, there is almost no generation of coherent phonons. For the pump-probe response we compute the conductivity induced by the probe pulse. The conductivity is a typical observable in real pump-probe experiments. Hence, it is possible to

  16. Conductivity of strongly pumped superconductors. An electron-phonon system far from equilibrium

    International Nuclear Information System (INIS)

    Krull, Holger

    2015-01-01

    The study of nonequilibrium physics is of great interest, because one can capture novel phenomena and properties which are hidden at equilibrium, e.g., one can study relaxation processes. A common way to study the nonequilibrium dynamics of a sample is a pump-probe experiment. In a pump probe experiment an intense laser pulse, the so called pump pulse, excites the sample and takes it out of equilibrium. After a certain delay time a second pulse, the probe pulse, measures the actual state of the sample. In this thesis, we theoretically study the pump-probe response of superconductors. On the one hand we are interest in the effect of a pump pulse and on the other hand we want to provide the pump-probe response, such that experimental measurement can be easily interpreted. In order to do this, we use the density matrix formalism to compute the pump-probe response of the system. In the density matrix formalism equations of motion are set up for expectation values of interest. In order to study the dynamics induced by a pump pulse, we compute the temporal evolution of the quasiparticle densities and the mean phonon amplitude. We find that the induced dynamics of the system depends on characteristics of the pump pulse. For short pulses, the system is pushed into the nonadiabatic regime. In this regime, the order parameter is lowered during the pump pulse and shows a 1/(√(t))-decaying oscillation afterwards. In addition, coherent phonons are generated, which is resonantly enhanced if the frequency of the order parameter oscillation is equal to the phonon frequency. For long pulses, the system is pushed into the adiabatic regime. In this regime, the order parameter is lowered during the pulse and remains almost constant afterwards. Further, there is almost no generation of coherent phonons. For the pump-probe response we compute the conductivity induced by the probe pulse. The conductivity is a typical observable in real pump-probe experiments. Hence, it is possible to

  17. Enzyme reactions and their time resolved measurements

    International Nuclear Information System (INIS)

    Hajdu, Janos

    1990-01-01

    This paper discusses experimental strategies in data collection with the Laue method and summarises recent results using synchrotron radiation. Then, an assessment is made of the progress towards time resolved studies with protein crystals and the problems that remain. The paper consists of three parts which respectively describe some aspects of Laue diffraction, recent examples of structural results from Laue diffraction, and kinetic Laue crystallography. In the first part, characteristics of Laue diffraction is discussed first, focusing on the harmonics problems, spatials problem, wavelength normalization, low resolution hole, data completeness, and uneven coverage of reciprocal space. Then, capture of the symmetry unique reflection set is discussed focusing on the effect of wavelength range on the number of reciprocal lattice points occupying diffracting positions, effect of crystal to film distance and the film area and shape on the number of reflections captured, and effect of crystal symmetry on the number of unique reflections within the number of reflections captured. The second part addresses the determination of the structure of turkey egg white lysozyme, and calcium binding in tomato bushy stunt virus. The third part describes the initiation of reactions in enzyme crystals, picosecond Laue diffraction at high energy storage rings, and detectors. (N.K.)

  18. Periodic and uniform nanogratings formed on cemented carbide by femtosecond laser scanning

    International Nuclear Information System (INIS)

    Lian, Yunsong; Deng, Jianxin; Xing, Youqiang; Lei, Shuting; Yu, Xiaoming

    2013-01-01

    Periodic and uniform nanogratings are fabricated by femtosecond laser scanning on cemented carbide. Specifically, three experiments are designed to study the influence of single pulse energy, scanning speed, and scanning spacing on the period and the uniformity of the formed nanogratings. The results show that the sample with single pulse energy of 2 μJ, scanning speed of 1000 μm/s, and scanning spacing of 5 μm shows the best quality of nanogratings among all the tested samples at different processing parameters. The uniformity of the nanogratings is largely determined by single pulse energy, scanning speed, and scanning spacing. Single pulse energy and scanning speed significantly affect the period of the nanogratings, whereas the period of the nanogratings maintains a fixed value under different scanning spacings. The period of the nanogratings increases gradually with the decrease of the single pulse energy and the increase of the scanning speed, respectively.

  19. Non linear characterisation of optical components of a high power laser chain

    International Nuclear Information System (INIS)

    Santran, Stephane

    2000-01-01

    This work concerns the realisation of non linear properties measurement prototypes in glasses in the near infrared and in the visible range. The various devices are time resolved colinear pump probe experiments in which the non linear susceptibility is deduced by the probe beam intensity variations induced by the pump probe coupled in the material. The sensitivity of these experiments allows us to observe unexpected variations, greater than 30%, of several fused silica non linear indexes. As well, this allow us to analyse the origin of the promising oxide glasses non linearity for all optical applications and to understand an d measure non linear processes in the two photons photodiodes. Finally, an original structure for the non linear index measurement in non degenerated configuration by a probe pulse phase measurement approach with a Sagnac interferometer is demonstrated and analysed. (author) [fr

  20. Flexible digital signal processing architecture for narrowband and spread-spectrum lock-in detection in multiphoton microscopy and time-resolved spectroscopy.

    Science.gov (United States)

    Wilson, Jesse W; Park, Jong Kang; Warren, Warren S; Fischer, Martin C

    2015-03-01

    The lock-in amplifier is a critical component in many different types of experiments, because of its ability to reduce spurious or environmental noise components by restricting detection to a single frequency and phase. One example application is pump-probe microscopy, a multiphoton technique that leverages excited-state dynamics for imaging contrast. With this application in mind, we present here the design and implementation of a high-speed lock-in amplifier on the field-programmable gate array (FPGA) coprocessor of a data acquisition board. The most important advantage is the inherent ability to filter signals based on more complex modulation patterns. As an example, we use the flexibility of the FPGA approach to enable a novel pump-probe detection scheme based on spread-spectrum communications techniques.

  1. Coupling of Higgs and Leggett modes in non-equilibrium superconductors.

    Science.gov (United States)

    Krull, H; Bittner, N; Uhrig, G S; Manske, D; Schnyder, A P

    2016-06-21

    In equilibrium systems amplitude and phase collective modes are decoupled, as they are mutually orthogonal excitations. The direct detection of these Higgs and Leggett collective modes by linear-response measurements is not possible, because they do not couple directly to the electromagnetic field. In this work, using numerical exact simulations we show for the case of two-gap superconductors, that optical pump-probe experiments excite both Higgs and Leggett modes out of equilibrium. We find that this non-adiabatic excitation process introduces a strong interaction between the collective modes, which is absent in equilibrium. Moreover, we propose a type of pump-probe experiment, which allows to probe and coherently control the Higgs and Leggett modes, and thus the order parameter directly. These findings go beyond two-band superconductors and apply to general collective modes in quantum materials.

  2. A flexible experimental setup for femtosecond time-resolved broad-band ellipsometry and magneto-optics

    Energy Technology Data Exchange (ETDEWEB)

    Boschini, F.; Hedayat, H.; Piovera, C.; Dallera, C. [Dipartimento di Fisica, Politecnico di Milano, p.zza Leonardo da Vinci 32, 20133 Milano (Italy); Gupta, A. [Department of Chemistry, University of Alabama, Tuscaloosa, Alabama 35487 (United States); Carpene, E., E-mail: ettore.carpene@polimi.it [CNR-IFN, Dipartimento di Fisica, Politecnico di Milano, p.zza Leonardo da Vinci 32, 20133 Milano (Italy)

    2015-01-15

    A versatile experimental setup for femtosecond time-resolved ellipsometry and magneto-optical Kerr effect measurements in the visible light range is described. The apparatus is based on the pump-probe technique and combines a broad-band probing beam with an intense near-infrared pump. According to Fresnel scattering matrix formalism, the analysis of the reflected beam at different polarization states of the incident probe light allows one to determine the diagonal and the off-diagonal elements of the dielectric tensor in the investigated sample. Moreover, the pump-probe method permits to study the dynamics of the dielectric response after a short and intense optical excitation. The performance of the experimental apparatus is tested on CrO{sub 2} single crystals as a benchmark.

  3. Ultrafast excited state relaxation in long-chain polyenes

    International Nuclear Information System (INIS)

    Antognazza, Maria Rosa; Lueer, Larry; Polli, Dario; Christensen, Ronald L.; Schrock, Richard R.; Lanzani, Guglielmo; Cerullo, Giulio

    2010-01-01

    Graphical abstract: Excited state dynamics of a long-chain polyene studied by femtosecond pump-probe spectroscopy. - Abstract: We present a comprehensive study, by femtosecond pump-probe spectroscopy, of excited state dynamics in a polyene that approaches the infinite chain limit. By excitation with sub-10-fs pulses resonant with the 0-0 S 0 → S 2 transition, we observe rapid loss of stimulated emission from the bright excited state S 2 , followed by population of the hot S 1 state within 150 fs. Vibrational cooling of S 1 takes place within 500 fs and is followed by decay back to S 0 with 1 ps time constant. By excitation with excess vibrational energy we also observe the ultrafast formation of a long-living absorption, that is assigned to the triplet state generated by singlet fission.

  4. Simultaneous all-optical determination of molecular concentration and extinction coefficient.

    Science.gov (United States)

    Cho, Byungmoon; Tiwari, Vivek; Jonas, David M

    2013-06-04

    Absolute molecular number concentration and extinction coefficient are simultaneously determined from linear and nonlinear spectroscopic measurements. This method is based on measurements of absolute femtosecond pump-probe signals. Accounting for pulse propagation, we present a closed form expression for molecular number concentration in terms of absorbance, fluorescence, absolute pump-probe signal, and laser pulse parameters (pulse energy, spectrum, and spatial intensity profile); all quantities are measured optically. As in gravimetric and coulometric determinations of concentration, no standard samples are needed for calibration. The extinction coefficient can then be determined from the absorbance spectrum and the concentration. For fluorescein in basic methanol, the optically determined molar concentrations and extinction coefficients match gravimetric determinations to within 10% for concentrations from 0.032 to 0.540 mM, corresponding to absorbance from 0.06 to 1. In principle, this photonumeric method is extensible to transient chemical species for which other methods are not available.

  5. Enhancing the blue shift of SHG signal in GaSe:B/Ce crystal

    Science.gov (United States)

    Karatay, Ahmet; Yuksek, Mustafa; Ertap, Hüseyin; Elmali, Ayhan; Karabulut, Mevlut

    2018-02-01

    The influence of Ce3+ on the wavelength of second harmonic generation (SHG) signal in boron doped GaSe crystals have been investigated. We found that by substitution of Ce3+ with B3+, SHG signal shifted to lower wavelength. In addition, the nonlinear absorption (NA) properties and ultrafast dynamics of pure, 1 at.% B3+ and 0.5 at.% B3++ 0.5 at.% Ce3+ doped GaSe crystals have been studied by open aperture Z-scan and ultrafast pump probe spectroscopy techniques. From the open aperture Z-scan experiments we observed that all of the crystals showed nonlinear absorption (NA). However, pump-probe experiments revealed that when GaSe crystal is doped, the NA signal turns into a bleaching signal with different lifetimes depending on the type and concentration of the dopant atoms.

  6. Gain dynamics of quantum dot devices for dual-state operation

    Energy Technology Data Exchange (ETDEWEB)

    Kaptan, Y., E-mail: yuecel.kaptan@physik.tu-berlin.de; Herzog, B.; Kolarczik, M.; Owschimikow, N.; Woggon, U. [Institut für Optik und Atomare Physik, Technische Universität Berlin, Berlin (Germany); Schmeckebier, H.; Arsenijević, D.; Bimberg, D. [Institut für Festkörperphysik, Technische Universität Berlin, Berlin (Germany); Mikhelashvili, V.; Eisenstein, G. [Technion Institute of Technology, Faculty of Electrical Engineering, Haifa (Israel)

    2014-06-30

    Ground state gain dynamics of In(Ga)As-quantum dot excited state lasers are investigated via single-color ultrafast pump-probe spectroscopy below and above lasing threshold. Two-color pump-probe experiments are used to localize lasing and non-lasing quantum dots within the inhomogeneously broadened ground state. Single-color results yield similar gain recovery rates of the ground state for lasing and non-lasing quantum dots decreasing from 6 ps to 2 ps with increasing injection current. We find that ground state gain dynamics are influenced solely by the injection current and unaffected by laser operation of the excited state. This independence is promising for dual-state operation schemes in quantum dot based optoelectronic devices.

  7. Ultrafast collinear scattering and carrier multiplication in graphene.

    Science.gov (United States)

    Brida, D; Tomadin, A; Manzoni, C; Kim, Y J; Lombardo, A; Milana, S; Nair, R R; Novoselov, K S; Ferrari, A C; Cerullo, G; Polini, M

    2013-01-01

    Graphene is emerging as a viable alternative to conventional optoelectronic, plasmonic and nanophotonic materials. The interaction of light with charge carriers creates an out-of-equilibrium distribution, which relaxes on an ultrafast timescale to a hot Fermi-Dirac distribution, that subsequently cools emitting phonons. Although the slower relaxation mechanisms have been extensively investigated, the initial stages still pose a challenge. Experimentally, they defy the resolution of most pump-probe setups, due to the extremely fast sub-100 fs carrier dynamics. Theoretically, massless Dirac fermions represent a novel many-body problem, fundamentally different from Schrödinger fermions. Here we combine pump-probe spectroscopy with a microscopic theory to investigate electron-electron interactions during the early stages of relaxation. We identify the mechanisms controlling the ultrafast dynamics, in particular the role of collinear scattering. This gives rise to Auger processes, including charge multiplication, which is key in photovoltage generation and photodetectors.

  8. Isolating strong-field dynamics in molecular systems

    Science.gov (United States)

    Orenstein, Gal; Pedatzur, Oren; Uzan, Ayelet J.; Bruner, Barry D.; Mairesse, Yann; Dudovich, Nirit

    2017-05-01

    Strong-field ionization followed by recollision provides a unique pump-probe measurement which reveals a range of electronic processes, combining sub-Angstrom spatial and attosecond temporal resolution. A major limitation of this approach is imposed by the coupling between the spatial and temporal degrees of freedom. In this paper we focus on the study of high harmonic generation and demonstrate the ability to isolate the internal dynamics—decoupling the temporal information from the spatial one. By applying an in situ approach we reveal the universality of the intrinsic pump-probe measurement and establish its validity in molecular systems. When several orbitals are involved we identify the fingerprint of the transition from the single-channel case into the multiple-channel dynamics, where complex multielectron phenomena are expected to be observed.

  9. A flexible experimental setup for femtosecond time-resolved broad-band ellipsometry and magneto-optics

    International Nuclear Information System (INIS)

    Boschini, F.; Hedayat, H.; Piovera, C.; Dallera, C.; Gupta, A.; Carpene, E.

    2015-01-01

    A versatile experimental setup for femtosecond time-resolved ellipsometry and magneto-optical Kerr effect measurements in the visible light range is described. The apparatus is based on the pump-probe technique and combines a broad-band probing beam with an intense near-infrared pump. According to Fresnel scattering matrix formalism, the analysis of the reflected beam at different polarization states of the incident probe light allows one to determine the diagonal and the off-diagonal elements of the dielectric tensor in the investigated sample. Moreover, the pump-probe method permits to study the dynamics of the dielectric response after a short and intense optical excitation. The performance of the experimental apparatus is tested on CrO 2 single crystals as a benchmark

  10. Confined longitudinal acoustic phonon modes in free-standing Si membranes coherently excited by femtosecond laser pulses

    OpenAIRE

    Hudert, Florian; Bruchhausen, Axel; Issenmann, Daniel; Schecker, Olivier; Waitz, Reimar; Erbe, Artur; Scheer, Elke; Dekorsy, Thomas; Mlayah, Adnen; Huntzinger, Jean-Roch

    2009-01-01

    In this Rapid Communication we report the first time-resolved measurements of confined acoustic phonon modes in free-standing Si membranes excited by fs laser pulses. Pump-probe experiments using asynchronous optical sampling reveal the impulsive excitation of discrete acoustic modes up to the 19th harmonic order for membranes of two different thicknesses. The modulation of the membrane thickness is measured with fm resolution. The experimental results are compared with a theoretical model in...

  11. Observations of subpicosecond dynamics in GaAlAs laser diodes

    Energy Technology Data Exchange (ETDEWEB)

    Stix, M.S.; Kesler, M.P.; Ippen, E.P.

    1986-06-23

    We present results of pump-probe experiments on GaAlAs laser diodes indicating a 0.9-ps relaxation time associated with the device transmission. Subpicosecond, tunable near infrared pulses obtained by fiber compression were used to carry out the experiments. The data strongly support a model in which a nonequilibrium carrier temperature in the active layer is responsible for the observed signal.

  12. Femtosecond spectroscopy on alkali-doped helium nanodroplets; Femtosekundenspektroskopie an alkalidotierten Helium-Nanotroepfchen

    Energy Technology Data Exchange (ETDEWEB)

    Claas, P.

    2006-01-15

    In the present thesis first studies on the short-time dynamics in alkali dimers and microclusters, which were bound on the surface of superfluid helium droplets, were presented. The experiments comprehended pump-probe measurements on the fs scale on the vibration dynamics on the dimers and on the fragmentation dynamics on the clusters. Generally by the studies it was shown that such extremely short slopes can also be observed on helium droplets by means of the femtosecond spectroscopy.

  13. Photoionization of atmospheric gases studied by time-resolved terahertz spectroscopy

    Czech Academy of Sciences Publication Activity Database

    Mics, Zoltan; Kužel, Petr; Jungwirth, Pavel; Bradforth, S. E.

    2008-01-01

    Roč. 465, 1-3 (2008), s. 20-24 ISSN 0009-2614 R&D Projects: GA MŠk LC512; GA ČR(CZ) GA202/06/0286 Institutional research plan: CEZ:AV0Z10100520; CEZ:AV0Z40550506 Keywords : terahertz * pump -probe * atmospheric gases * photoionization * plasma Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 2.169, year: 2008

  14. Twisting Anderson pseudospins with light: Quench dynamics in THz-pumped BCS superconductors

    OpenAIRE

    Chou, Yang-Zhi; Liao, Yunxiang; Foster, Matthew S.

    2016-01-01

    We study the preparation (pump) and the detection (probe) of far-from-equilibrium BCS superconductor dynamics in THz pump-probe experiments. In a recent experiment [R. Matsunaga, Y. I. Hamada, K. Makise, Y. Uzawa, H. Terai, Z. Wang, and R. Shimano, Phys. Rev. Lett. {\\bf 111}, 057002 (2013)], an intense monocycle THz pulse with center frequency $\\omega \\simeq \\Delta$ was injected into a superconductor with BCS gap $\\Delta$; the subsequent post-pump evolution was detected via the optical conduc...

  15. Interferometry on small quantum systems at short wavelength

    International Nuclear Information System (INIS)

    Usenko, Sergey

    2017-01-01

    The present work concentrates on prototypical studies of light-induced correlated many-body dynamics in complex systems. In its course a reflective split-and-delay unit (SDU) for phase-resolved one-color pump-probe experiments with gas phase samples using VUV-XUV laser pulses was built. The collinear propagation of pump and probe pulses is ensured by the special geometry of the SDU and allows to perform phase-resolved (coherent) autocorrelation measurements. The control of the pump-probe delay with attosecond precision is established by a specially developed diagnostic tool based on an in-vacuum white light interferometer that allows to monitor the relative displacement of the SDU reflectors with nanometer resolution. Phase-resolved (interferometric) pump-probe experiments with developed SDU require spatially-resolved imaging of the ionization volume. For this an electron-ion coincidence spectrometer was built. The spectrometer enables coincident detection of photoionization products using velocity map imaging (VMI) technique for electrons and VMI or spatial imaging for ions. In first experiments using the developed SDU and the spectrometer in the ion spatial-imaging mode linear field autocorrelation of free-electron laser pulses at the central wavelength of 38 nm was recorded. A further focus of the work were energy- and time-resolved resonant two-photon ionization experiments using short tunable UV laser pulses on C_6_0 fullerene. The experiments demonstrated that dipole-selective excitation on a timescale faster than the characteristic intramolecular energy dissipation limits the number of accessible excitation pathways and thus results in a narrow resonance. Time-dependent one-color pump-probe study showed that nonadiabatic (vibron) coupling is the dominant energy dissipation mechanism for high-lying electronic excited states in C_6_0.

  16. Interferometry on small quantum systems at short wavelength

    Energy Technology Data Exchange (ETDEWEB)

    Usenko, Sergey

    2017-01-15

    The present work concentrates on prototypical studies of light-induced correlated many-body dynamics in complex systems. In its course a reflective split-and-delay unit (SDU) for phase-resolved one-color pump-probe experiments with gas phase samples using VUV-XUV laser pulses was built. The collinear propagation of pump and probe pulses is ensured by the special geometry of the SDU and allows to perform phase-resolved (coherent) autocorrelation measurements. The control of the pump-probe delay with attosecond precision is established by a specially developed diagnostic tool based on an in-vacuum white light interferometer that allows to monitor the relative displacement of the SDU reflectors with nanometer resolution. Phase-resolved (interferometric) pump-probe experiments with developed SDU require spatially-resolved imaging of the ionization volume. For this an electron-ion coincidence spectrometer was built. The spectrometer enables coincident detection of photoionization products using velocity map imaging (VMI) technique for electrons and VMI or spatial imaging for ions. In first experiments using the developed SDU and the spectrometer in the ion spatial-imaging mode linear field autocorrelation of free-electron laser pulses at the central wavelength of 38 nm was recorded. A further focus of the work were energy- and time-resolved resonant two-photon ionization experiments using short tunable UV laser pulses on C{sub 60} fullerene. The experiments demonstrated that dipole-selective excitation on a timescale faster than the characteristic intramolecular energy dissipation limits the number of accessible excitation pathways and thus results in a narrow resonance. Time-dependent one-color pump-probe study showed that nonadiabatic (vibron) coupling is the dominant energy dissipation mechanism for high-lying electronic excited states in C{sub 60}.

  17. Optoacoustic characterization of synthetic opals

    International Nuclear Information System (INIS)

    Mechri, C; Ruello, P; Mounier, D; Breteau, J M; Povey, I; Pemble, M; Romanov, S G; Gusev, V

    2007-01-01

    The development of laser-based ultrafast acoustic techniques allowed the investigation of the vibrations of nanostructures. In this communication, we report the results of the characterization of crystals composed of silica nanospheres (opals) by pump-probe setup. In our study, the excitation and detection of the vibrations of nanospheres by femtosecond laser pulses was facilitated by filling the pores in the opals by GaAs semiconducting material

  18. Picosecond absorption relaxation measured with nanosecond laser photoacoustics

    OpenAIRE

    Danielli, Amos; Favazza, Christopher P.; Maslov, Konstantin; Wang, Lihong V.

    2010-01-01

    Picosecond absorption relaxation—central to many disciplines—is typically measured by ultrafast (femtosecond or picosecond) pump-probe techniques, which however are restricted to optically thin and weakly scattering materials or require artificial sample preparation. Here, we developed a reflection-mode relaxation photoacoustic microscope based on a nanosecond laser and measured picosecond absorption relaxation times. The relaxation times of oxygenated and deoxygenated hemoglobin molecules, b...

  19. Ultrafast Phase Transition in Vanadium Dioxide Driven by Hot-Electron Injection

    Directory of Open Access Journals (Sweden)

    Prasankumar R. P.

    2013-03-01

    Full Text Available We present a novel all-optical method of triggering the phase transition in vanadium dioxide by means of ballistic electrons injected across the interface between a mesh of Au nanoparticles coveringd VO2 nanoislands. By performing non-degenerate pump-probe transmission spectroscopy on this hybrid plasmonic/phase-changing nanostructure, structural and electronic dynamics can be retrieved and compared.

  20. Fluorescence lifetime measurement of radical ions

    International Nuclear Information System (INIS)

    Ichinose, Nobuyuki; Kinugasa, Jun-ichiro; Hagiri, Masahide; Nakayama, Toshihiro; Murakami, Hiroshi; Kishimoto, Maki; Daido, Hiroyuki

    2004-01-01

    One-photonic excitation of a charge transfer complex of hexamethoxybenzene (HMB) and nitrosonium tetrafluoroborate (NO + BF 4 - ) in acetonitrile afforded fluorescences emission from excited radical cation of HMB (HMB + *). Lifetime of the excited radical ion species was measured to be 7 ps by the pump-probe transient absorption technique. The lifetime was much shorter than that of free radical ion (63 ps), indicating the presence of an interaction between HMB + * and NO in the excited complex. (author)

  1. Optical Detection in Ultrafast Short Wavelength Science

    International Nuclear Information System (INIS)

    Fullagar, Wilfred K.; Hall, Chris J.

    2010-01-01

    A new approach to coherent detection of ionising radiation is briefly motivated and recounted. The approach involves optical scattering of coherent light fields by colour centres in transparent solids. It has significant potential for diffractive imaging applications that require high detection dynamic range from pulsed high brilliance short wavelength sources. It also motivates new incarnations of Bragg's X-ray microscope for pump-probe studies of ultrafast molecular structure-dynamics.

  2. Energy transfer properties and mechanisms

    International Nuclear Information System (INIS)

    Barker, J.R.

    1993-01-01

    Since no single experimental technique is the best method for energy transfer experiments, we have used both time-dependent infrared fluorescence (IRF) and time-dependent thermal lensing (TDTL) to study energy transfer in various systems. We are investigating pump-probe techniques employing resonance enhanced multiphoton ionization (REMPI). IRF was used to study benzene, azulene, and toluene. TDTL was used to study CS 2 and SO 2 (data not given for latter). Large molecule energy transfer mechanisms are discussed. 10 figs

  3. Exploring Ultrafast Structural Dynamics for Energetic Enhancement or Disruption

    Science.gov (United States)

    2016-03-01

    it. In a pump -push/ dump probe experiment, a secondary laser pulse (push/ dump ) is used after the initial perturbation due to the pump pulse. The...increased. The pump -push/ dump probe technique is a difficult experiment that requires a highly stable laser source. Ultrafast pump -probe experiments...decomposition of solids. Journal of Applied Physics. 2001;89:4156–4166. 17. Kee TW. Femtosecond pump -push-probe and pump - dump -probe spectroscopy of

  4. Coherent evolution of parahydrogen induced polarisation using laser pump, NMR probe spectroscopy: Theoretical framework and experimental observation.

    Science.gov (United States)

    Halse, Meghan E; Procacci, Barbara; Henshaw, Sarah-Louise; Perutz, Robin N; Duckett, Simon B

    2017-05-01

    We recently reported a pump-probe method that uses a single laser pulse to introduce parahydrogen (p-H 2 ) into a metal dihydride complex and then follows the time-evolution of the p-H 2 -derived nuclear spin states by NMR. We present here a theoretical framework to describe the oscillatory behaviour of the resultant hyperpolarised NMR signals using a product operator formalism. We consider the cases where the p-H 2 -derived protons form part of an AX, AXY, AXYZ or AA'XX' spin system in the product molecule. We use this framework to predict the patterns for 2D pump-probe NMR spectra, where the indirect dimension represents the evolution during the pump-probe delay and the positions of the cross-peaks depend on the difference in chemical shift of the p-H 2 -derived protons and the difference in their couplings to other nuclei. The evolution of the NMR signals of the p-H 2 -derived protons, as well as the transfer of hyperpolarisation to other NMR-active nuclei in the product, is described. The theoretical framework is tested experimentally for a set of ruthenium dihydride complexes representing the different spin systems. Theoretical predictions and experimental results agree to within experimental error for all features of the hyperpolarised 1 H and 31 P pump-probe NMR spectra. Thus we establish the laser pump, NMR probe approach as a robust way to directly observe and quantitatively analyse the coherent evolution of p-H 2 -derived spin order over micro-to-millisecond timescales. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  5. Signatures of collective electron dynamics in the angular distributions of electrons ejected during ultrashort laser pulse interactions with C+

    International Nuclear Information System (INIS)

    Lysaght, M A; Hutchinson, S; Van der Hart, H W

    2009-01-01

    We use the time-dependent R-matrix approach to investigate an ultrashort pump-probe scheme to observe collective electron dynamics in C + driven by the repulsion of two equivalent p electrons. By studying the two-dimensional momentum distributions of the ejected electron as a function of the time-delay between an ultrashort pump pulse and an ionizing ultrashort probe pulse it is possible to track the collective dynamics inside the C + ion in the time domain.

  6. X-RAY ACTIVE MATRIX PIXEL SENSORS BASEDON J-FET TECHNOLOGY DEVELOPED FOR THE LINAC COHERENT LIGHT SOURCE.

    Energy Technology Data Exchange (ETDEWEB)

    CARINI,G.A.; CHEN, W.; LI, Z.; REHAK, P.; SIDDONS, D.P.

    2007-10-29

    An X-ray Active Matrix Pixel Sensor (XAMPS) is being developed for recording data for the X-ray Pump Probe experiment at the Linac Coherent Light Source (LCLS). Special attention has to be paid to some technological challenges that this design presents. New processes were developed and refined to address problems encountered during previous productions of XAMPS. The development of these critical steps and corresponding tests results are reported here.

  7. Photodynamic processes in LiCaAlF6:Ce3+ UV active medium

    International Nuclear Information System (INIS)

    Galiev, A I; Semashko, V V; Akhtyamov, O R; Shnaidman, S A; Marisov, M A; Shavelev, A A

    2014-01-01

    The objectives of this paper are experimental studies of pump-induced effects in LiCaAlF 6 : Ce 3+ single crystals and computer model elaboration and appropriated software package engineering. The elaborated experimental technique and software allow either to calculate the nonlinear absorption/gain characteristics of the active medium on the basis of known parameters, or to find its previously unknown parameters from pump-probe experimental dependences

  8. Transverse emittance measurement at REGAE via a solenoid scan

    Energy Technology Data Exchange (ETDEWEB)

    Hachmann, Max; Mayet, Frank; Gruener, Florian [Institut fuer Experimentalphysik, Universitaet Hamburg (Germany); Floettmann, Klaus [DESY, Hamburg (Germany)

    2013-07-01

    The linear accelerator REGAE at DESY produces short and low charged electron bunches, on the one hand to resolve the excitation transitions of atoms temporally by pump probe electron diffraction experiments and on the other hand to investigate principal mechanisms of laser plasma acceleration. For both cases a high quality electron beam is required which can be identified with a small beam emittance. The current method to measure the transverse beam emittance at REGAE and results are presented.

  9. Ultrafast Gain Dynamics in Quantum Dot Amplifiers: Theoretical Analysis and Experimental Investigations

    DEFF Research Database (Denmark)

    Poel, Mike van der; Gehrig, Edeltraud; Hess, Ortwin

    2005-01-01

    Ultrafast gain dynamics in an optical amplifier with an active layer of self-organized quantum dots (QDs) emitting near 1.3$muhbox m$is characterized experimentally in a pump-probe experiment and modeled theoretically on the basis of QD Maxwell–Bloch equations. Experiment and theory are in good......$factor) is theoretically predicted and demonstrated in the experiments. The fundamental analysis reveals the underlying physical processes and indicates limitations to QD-based devices....

  10. Different Response of Carbonyl Carotenoids to Solvent Proticity Helps To Estimate Structure of the Unknown Carotenoid from Chromera velia

    Czech Academy of Sciences Publication Activity Database

    Kesan, G.; Durchan, Milan; Tichý, Josef; Minofar, Babak; Kuznetsova, V.; Fuciman, M.; Šlouf, V.; Parlak, C.; Polívka, Tomáš

    2015-01-01

    Roč. 119, č. 39 (2015), s. 12653-12663 ISSN 1520-6106 R&D Projects: GA ČR(CZ) GAP205/11/1164; GA ČR GBP501/12/G055 Institutional support: RVO:60077344 ; RVO:67179843 Keywords : Charge-transfer state * Time-resolved spectroscopy * Pump-probe spectroscopy * Apicomplexan parasites Subject RIV: BO - Biophysics; BO - Biophysics (UEK-B) Impact factor: 3.187, year: 2015

  11. Theory for Nonlinear Spectroscopy of Vibrational Polaritons

    OpenAIRE

    Ribeiro, RF; Dunkelberger, AD; Xiang, B; Xiong, W; Simpkins, BS; Owrutsky, JC; Yuen-Zhou, J

    2017-01-01

    Molecular polaritons have gained considerable attention due to their potential to control nanoscale molecular processes by harnessing electromagnetic coherence. Although recent experiments with liquid-phase vibrational polaritons have shown great promise for exploiting these effects, significant challenges remain in interpreting their spectroscopic signatures. In this letter, we develop a quantum-mechanical theory of pump-probe spectroscopy for this class of polaritons based on the quantum La...

  12. Testing of quality of welded joints using heavy-current pulse X-ray apparatuses

    International Nuclear Information System (INIS)

    Gusev, E.A.; Firstov, V.G.

    1988-01-01

    The possibilities of carrying out of radiographic and electroradiographic testing of quality of welded joints using heavy-current pulse X-ray apparatuses under the mode of single pulses are shown. Basic quantitative characteristics of radiographic testing permitting to detect the focus distance, sensitivity behaviour and optical density of image are presented. Peculiarities of electroradiographic image formation under the mode of single pulses of nanosecond range are analysed. The outlook of heavy-current pulse X-ray apparatus application under the mode of single pulses in industry is estimated

  13. Charge and pairing dynamics in the attractive Hubbard model: Mode coupling and the validity of linear-response theory

    Science.gov (United States)

    Bünemann, Jörg; Seibold, Götz

    2017-12-01

    Pump-probe experiments have turned out as a powerful tool in order to study the dynamics of competing orders in a large variety of materials. The corresponding analysis of the data often relies on standard linear-response theory generalized to nonequilibrium situations. Here we examine the validity of such an approach for the charge and pairing response of systems with charge-density wave and (or) superconducting (SC) order. Our investigations are based on the attractive Hubbard model which we study within the time-dependent Hartree-Fock approximation. In particular, we calculate the quench and pump-probe dynamics for SC and charge order parameters in order to analyze the frequency spectra and the coupling of the probe field to the specific excitations. Our calculations reveal that the "linear-response assumption" is justified for small to moderate nonequilibrium situations (i.e., pump pulses) in the case of a purely charge-ordered ground state. However, the pump-probe dynamics on top of a superconducting ground state is determined by phase and amplitude modes which get coupled far from the equilibrium state indicating the failure of the linear-response assumption.

  14. A correlation between the defect states and yellow luminescence in AlGaN/GaN heterostructures

    Science.gov (United States)

    Jana, Dipankar; Sharma, T. K.

    2017-07-01

    AlGaN/GaN heterostructures are investigated by performing complementary spectroscopic measurements under novel experimental configurations. Distinct features related to the band edge of AlGaN and GaN layers are clearly observed in surface photovoltage spectroscopy (SPS) spectra. A few more SPS features, which are associated with defects in GaN, are also identified by performing the pump-probe SPS measurements. SPS results are strongly corroborated by the complementary photoluminescence and photoluminescence excitation (PLE) measurements. A correlation between the defect assisted SPS features and yellow luminescence (YL) peak is established by performing pump-probe SPS and PLE measurements. It is found that CN-ON donor complex is responsible for the generation of YL peak in our sample. Further, the deep trap states are found to be present throughout the entire GaN epilayer. It is also noticed that the deep trap states lying at the GaN/Fe-GaN interface make a strong contribution to the YL feature. A phenomenological model is proposed to explain the intensity dependence of the YL feature and the corresponding SPS features in a pump-probe configuration, where a reasonable agreement between the numerical simulations and experimental results is achieved.

  15. Charge dynamics in aluminum oxide thin film studied by ultrafast scanning electron microscopy.

    Science.gov (United States)

    Zani, Maurizio; Sala, Vittorio; Irde, Gabriele; Pietralunga, Silvia Maria; Manzoni, Cristian; Cerullo, Giulio; Lanzani, Guglielmo; Tagliaferri, Alberto

    2018-04-01

    The excitation dynamics of defects in insulators plays a central role in a variety of fields from Electronics and Photonics to Quantum computing. We report here a time-resolved measurement of electron dynamics in 100 nm film of aluminum oxide on silicon by Ultrafast Scanning Electron Microscopy (USEM). In our pump-probe setup, an UV femtosecond laser excitation pulse and a delayed picosecond electron probe pulse are spatially overlapped on the sample, triggering Secondary Electrons (SE) emission to the detector. The zero of the pump-probe delay and the time resolution were determined by measuring the dynamics of laser-induced SE contrast on silicon. We observed fast dynamics with components ranging from tens of picoseconds to few nanoseconds, that fits within the timescales typical of the UV color center evolution. The surface sensitivity of SE detection gives to the USEM the potential of applying pump-probe investigations to charge dynamics at surfaces and interfaces of current nano-devices. The present work demonstrates this approach on large gap insulator surfaces. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Time resolved resonant inelastic X-ray scattering: A supreme tool to understand dynamics in solids and molecules

    International Nuclear Information System (INIS)

    Beye, M.; Wernet, Ph.; Schüßler-Langeheine, C.; Föhlisch, A.

    2013-01-01

    Highlights: •The high specificity of RIXS ideally suits time-resolved measurements. •Methods relating to the core hole lifetime cover the low femtosecond regime. •Pump-probe methods are used starting at sub-ps time scales. •FELs and synchrotrons are useful for pump-probe studies. •Examples from solid state dynamics and molecules are discussed. -- Abstract: Dynamics in materials typically involve different degrees of freedom, like charge, lattice, orbital and spin in a complex interplay. Time-resolved resonant inelastic X-ray scattering (RIXS) as a highly selective tool can provide unique insight and follow the details of dynamical processes while resolving symmetries, chemical and charge states, momenta, spin configurations, etc. In this paper, we review examples where the intrinsic scattering duration time is used to study femtosecond phenomena. Free-electron lasers access timescales starting in the sub-ps range through pump-probe methods and synchrotrons study the time scales longer than tens of ps. In these examples, time-resolved resonant inelastic X-ray scattering is applied to solids as well as molecular systems

  17. The two-wave X-ray field calculated by means of integral-equation methods

    International Nuclear Information System (INIS)

    Bremer, J.

    1984-01-01

    The problem of calculating the two-wave X-ray field on the basis of the Takagi-Taupin equations is discussed for the general case of curved lattice planes. A two-dimensional integral equation which incorporates the nature of the incoming radiation, the form of the crystal/vacuum boundary, and the curvature of the structure, is deduced. Analytical solutions for the symmetrical Laue case with incoming plane waves are obtained directly for perfect crystals by means of iteration. The same method permits a simple derivation of the narrow-wave Laue and Bragg cases. Modulated wave fronts are discussed, and it is shown that a cut-off in the width of an incoming plane wave leads to lateral oscillations which are superimposed on the Pendelloesung fringes. Bragg and Laue shadow fields are obtained. The influence of a non-zero kernel is discussed and a numerical procedure for calculating wave amplitudes in curved crystals is presented. (Auth.)

  18. Measurement of rocking curve wings at high x-ray energies

    International Nuclear Information System (INIS)

    Chapman, D.; Hastings, J.; Moulin, H.; Siddons, D.P.; Garrett, R.F.; Nachaliel, E.; Dilmanian, F.A.

    1991-01-01

    Measurements done recently at the NSLS have indicated that the level of intensity found in the wings of diffraction peaks from silicon at higher x-ray energies (>20keV) far exceeds the value which would be predicted based on the dynamical theory. We have measured Si(220) double crystal rocking curves at the 40keV fundamental and harmonics with various crystal scattering geometries: Bragg-Bragg, Laue-Bragg, Laue-Lauel. The comparison of the Bragg and Laue case diffraction geometries was done to determine scattering volume effects. Comparisons with dynamical theory calculations will be discussed. These measurements have been carried out in order to assess the level of harmonic contamination which will be present from a double crystal monochromator being designed for the X17 Superconducting Wiggler Beamline

  19. The strange rays of Professor Roentgen

    International Nuclear Information System (INIS)

    Guinier, A.

    1995-01-01

    This paper relates the historical discovery of X radiations in 1895 by the German Physicist Wilhelm Conrad Roendgen in his laboratory of Wurzburg University. Independently of Roendgen, several physicists such as Charles Glover Barkla, Jean Perrin or Max von Laue have tried to determine the nature of X rays. In 1912, in Cambridge (UK) William Henry and William Lawrence Bragg have used the X-ray diffraction property, discovered by Laue's team, to explore the atomic structure of crystals. The recent development of computers technology has considerably increased the automation of data collection and the analysis of complex diffraction diagrams. (J.S.). 3 refs., 3 photos

  20. The Ferrara hard X-ray facility for testing/calibrating hard X-ray focusing telescopes

    Science.gov (United States)

    Loffredo, Gianluca; Frontera, Filippo; Pellicciotta, Damiano; Pisa, Alessandro; Carassiti, Vito; Chiozzi, Stefano; Evangelisti, Federico; Landi, Luca; Melchiorri, Michele; Squerzanti, Stefano

    2005-12-01

    We will report on the current configuration of the X-ray facility of the University of Ferrara recently used to perform reflectivity tests of mosaic crystals and to calibrate the experiment JEM X aboard Integral. The facility is now located in the technological campus of the University of Ferrara in a new building (named LARIX laboratory= LARge Italian X-ray facility) that includes a tunnel 100 m long with, on the sides, two large experimental rooms. The facility is being improved for determining the optical axis of mosaic crystals in Laue configuration, for calibrating Laue lenses and hard X-ray mirror prototypes.

  1. A Green, Safe, Dual-pulse Solid Motor for CubeSat Orbit Changing, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Small satellites such as CubeSats are in need of responsive propulsion, but are limited due to their size. Though single pulse, AP/HTPB fueled solid rocket motors...

  2. Self-mode-locked Nd3+:YAG laser

    International Nuclear Information System (INIS)

    Komarov, A K; Komarov, K P; Kuch'yanov, Aleksandr S

    2003-01-01

    Self-mode-locking was observed in a Nd 3+ :YAG laser with a negative feedback without introducing any nonlinear elements into the laser cavity. The laser generates during pumping 300 - 500-ps single pulses on an axial period. (lasers)

  3. Injury Thresholds for Topical Cream-Coated Skin of Hairless Guinea Pigs (Cavia Procellus) in Near Infrared Region

    National Research Council Canada - National Science Library

    Stolarski, David J; Zohner, Justin J; Imholte, Michelle L; Chavey, Lucas J; Pocock, Ginger M; Buchanan, Kelvin C; Jindra, Nichole M; Figueroa, Manuel A; Thomas, Robert J; Rockwell, Benjamin A

    2006-01-01

    .... Hairless guinea pigs (cavia porcellus) in vivo were used to evaluate how the minimum visible lesion threshold for single-pulse laser exposure is changed with a topical agent applied to the skin...

  4. Feasibility of atomic and molecular laser induced breakdown spectroscopy (LIBS) to in-situ determination of chlorine in concrete : final report.

    Science.gov (United States)

    2016-10-01

    Laser-induced breakdown spectroscopy (LIBS) has been studied as a fast method of detecting chlorine in concrete samples. Both single pulse (SP) and double pulse (DP) experiments have been tested. Several combinations of lasers (Neodymium-Yttrium Alum...

  5. Theory and applications of maps on SO(3) in nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Cho, H.M.

    1987-02-01

    Theoretical approaches and experimental work in the design of multiple pulse sequences in Nuclear Magnetic Resonance (NMR) are the subjects of this dissertation. Sequences of discrete pulses which reproduce the nominal effect of single pulses, but over substantially broader, narrower, or more selective ranges of transition frequencies, radiofrequency field amplitudes, and spin-spin couplings than the single pulses they replace, are developed and demonstrated. 107 refs., 86 figs., 6 tabs

  6. Field-induced reentrant magnetoelectric phase in LiNiPO4

    DEFF Research Database (Denmark)

    Toft-Petersen, Rasmus; Fogh, Ellen; Kihara, Takumi

    2017-01-01

    Using pulsed magnetic fields up to 30 T we have measured the bulk magnetization and electrical polarization of LiNiPO4 and have studied its magnetic structure by time-of-flight neutron Laue diffraction. Our data establish the existence of a reentrant magnetoelectric phase between 19 T and 21 T. W...

  7. Annual report 86

    International Nuclear Information System (INIS)

    1987-01-01

    This report comes from the Institut Max von Laue-Langevin (ILL) at Grenoble. The purpose of the ILL differs from other research institutes as it is a service institute created so that chemistry, solid state physics, fundamental and nuclear physics, biology and metallurgy specialists can use the unique power of neutron techniques

  8. Designing new guides and instruments using McStas

    DEFF Research Database (Denmark)

    Farhi, E.; Hansen, T.; Wildes, A.

    2002-01-01

    of guides, neutron optics and instruments [1]. To date, the McStas package has been extensively used at the Institut Laue-Langevin, Grenoble, France, for various studies including cold and thermal guides with ballistic geometry, diffractometers, triple-axis, backscattering and time-of-flight spectrometers...

  9. Neutron diffractometers for structural biology at spallation neutron sources

    Energy Technology Data Exchange (ETDEWEB)

    Schoenborn, B.P.; Pitcher, E. [Los Alamos National Laboratory, NM (United States)

    1994-12-31

    Spallation neutron sources are ideal for diffraction studies of proteins and oriented molecular complexes. With spoliation neutrons and their time dependent wavelength structure, it is easy to electronically select data with an optimal wavelength bandwidth and cover the whole Laue spectrum as time (wavelength) resolved snapshots. This optimized data quality with best peak-to-background ratios and provides adequate spatial and energy resolution to eliminate peak overlaps. The application of this concept will use choppers to select the desired Laue wavelength spectrum and employ focusing optics and large cylindrical {sup 3}He detectors to optimize data collection rates. Such a diffractometer will cover a Laue wavelength range from 1 to 5{Angstrom} with a flight path length of 10m and an energy resolution of 0.25{Angstrom}. Moderator concepts for maximal flux distribution within this energy range will be discussed using calculated flux profiles. Since the energy resolution required for such timed data collection in this super Laue techniques is not very high, the use of a linac only (LAMPF) spoliation target is an exciting possibility with an order of magnitude increase in flux.

  10. Annual report 84

    International Nuclear Information System (INIS)

    1985-01-01

    The Institut Laue-Langevin (ILL) at Grenoble main activities are organized into 9 colleges and 3 departments. Colleges activities are: theory, fundamental and nuclear physics, structural and magnetic excitations, crystal and magnetic structures, liquids, disorders and defects in materials, biochemistry and chimistry. The two department activities are instrumentation and reactor operation

  11. Focusing Optics for High-Energy X-ray Diffraction

    DEFF Research Database (Denmark)

    Leinert, U.; Schulze, C.; Honkimäki, V.

    1998-01-01

    Novel focusing optical devices have been developed for synchrotron radiation in the energy range 40-100 keV. Firstly, a narrow-band-pass focusing energy-tuneable fixed-exit monochromator was constructed by combining meridionally bent Laue and Bragg crystals. Dispersion compensation was applied...

  12. Bull. Mater. Sci., Vol. 12, No. 2, July 1989, pp. 143-146

    Indian Academy of Sciences (India)

    As the morphology and crystal structure are not known, Laue photographs of faces c and b are taken (figure 2a, b). Face c (figure 2a) exhibits a C symmetry whereas the other (figure 2b) shows a C. symmetry. This symmetry suggests that the crystal must have the minimum symmetry of an orthorhombic crystal. Further, to ...

  13. Welding of a neutron high-flux reactor made of aluminum

    International Nuclear Information System (INIS)

    Zinser, P.; Schupp, N.

    1996-01-01

    The HFR300 of the Institute ''Max von Laue - Paul Langevin (ILL)'' at Grenoble was found to be damaged by a number of serious defects which could not be made good by repair work, so that a new reactor had to be installed. Some of the welding tasks performed so far in this installation are explained. (orig./MM) [de

  14. Annual Report 2000

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    The Institut Laue-Langevin (ILL) is an international research center using neutrons to probe the microscopic structure and dynamics of a broad range of materials. This annual report presents the ILL activities in 2000: the scientific highlights, the Millennium programme and the new developments, the workshops organized by the ILL, the experimental programme and the publications. (A.L.B.)

  15. GRI: focusing on the evolving violent universe

    DEFF Research Database (Denmark)

    Knodlseder, J.; von Ballmoos, P.; Frontera, F.

    2009-01-01

    The gamma-ray imager (GRI) is a novel mission concept that will provide an unprecedented sensitivity leap in the soft gamma-ray domain by using for the first time a focusing lens built of Laue diffracting crystals. The lens will cover an energy band from 200-1,300 keV with an effective area reach...... processes in the universe....

  16. Publication of the second amendment to the German-French Convention on the construction and operation of a very high flux reactor and to its complementary agreement

    International Nuclear Information System (INIS)

    1982-01-01

    Full text in German, English, and French of the amendment to the London Convention of December 9, 1981 between the Federal Republic of Germany, France, Great Britain and Northern Ireland concerning the operating cost and the use of the high flux reactor in Grenoble at the Max-von-Laue Institute. (HP) [de

  17. Bulletin of Materials Science | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    Sfax University, Faculty of Sciences, 3000 Sfax, Tunisia; Instituto de Ciencia de Materiales de Madrid, Consejo Superior de Investigaciones Científicas, Cantoblanco, E-28049 Madrid, Spain; Institut Laue-Langevin, F-38042 Grenoble Cedex 9, France; Sfax University, National School of Engineers, 3038 Sfax, Tunisia ...

  18. Neutron diffractometers for structural biology at spallation neutron sources

    International Nuclear Information System (INIS)

    Schoenborn, B.P.; Pitcher, E.

    1994-01-01

    Spallation neutron sources are ideal for diffraction studies of proteins and oriented molecular complexes. With spoliation neutrons and their time dependent wavelength structure, it is easy to electronically select data with an optimal wavelength bandwidth and cover the whole Laue spectrum as time (wavelength) resolved snapshots. This optimized data quality with best peak-to-background ratios and provides adequate spatial and energy resolution to eliminate peak overlaps. The application of this concept will use choppers to select the desired Laue wavelength spectrum and employ focusing optics and large cylindrical 3 He detectors to optimize data collection rates. Such a diffractometer will cover a Laue wavelength range from 1 to 5 Angstrom with a flight path length of 10m and an energy resolution of 0.25 Angstrom. Moderator concepts for maximal flux distribution within this energy range will be discussed using calculated flux profiles. Since the energy resolution required for such timed data collection in this super Laue techniques is not very high, the use of a linac only (LAMPF) spoliation target is an exciting possibility with an order of magnitude increase in flux

  19. Subwavelength Focalization of Acoustic Waves Using Time Reversal. Yes We Can!

    Science.gov (United States)

    El Abed, Mohamed

    2014-01-01

    By superimposing two sound waves of the same wavelength, propagating in the opposite direction, we can create an intensity pattern having a characteristic scale equal to half a wavelength: it is the diffraction limit. Recently a group from the Institut Laue-Langevin in Paris has shown that it is possible to go beyond this limit by focusing sound…

  20. Development status of a CZT spectrometer prototype with 3D spatial resolution for hand x-ray astronomy

    DEFF Research Database (Denmark)

    Auricchio, N.; Caroli, E.; Basili, A.

    2012-01-01

    The development of new focusing optics based on wide band Laue lenses operating from ~60 keV up to several hundred keV is particularly challenging. This type of hard X-ray or gamma ray optics requires a high performance focal plane detector in order to exploit to the best their intrinsic capabili...

  1. Development of a CZT spectroscopic 3D imager prototype for hard X ray astronomy

    DEFF Research Database (Denmark)

    Auricchio, N.; Caroli, E.; Basili, A.

    2013-01-01

    The development of focusing optics based on wide band Laue lenses operating from ∼60 keV up to several hundreds of keV is particularly challenging. This type of hard X-ray or gamma ray optics requires a high performance focal plane detector in order to exploit to the best its intrinsic capabiliti...

  2. The Effect of the Shape of Atomic Potential on the Diffraction Pattern ...

    African Journals Online (AJOL)

    We have simulated the diffraction patterns of both periodic and quasiperiodic monatomic chains using the code Laue (written by Silsbee and Drager) and investigated the effects of the shape of the atomic potential. Three fundamental differences between the diffraction patterns of periodic and quasiperiodic monatomic chain ...

  3. Simulation of the diffraction pattern of one dimensional quasicrystal ...

    African Journals Online (AJOL)

    The effects of the variation of atomic spacing ratio of a one dimensional quasicrystal material are investigated. The work involves the use of the solid state simulation code, Laue written by Silsbee and Drager. We are able to observe the general features of the diffraction pattern by a quasicrystal. In addition, it has been found ...

  4. New approach to the exotic phases of actinide compounds under unconventional experimental conditions

    International Nuclear Information System (INIS)

    Hiess, A.; Lander, G.H.

    2012-01-01

    We describe some collaborative experiments using large facilities that have been performed during the second year of the REIMEI project with the title above. Also discussed are the conclusions of the 2nd Workshop on this program, held at the Institut Laue Langevin, Grenoble, France, 1-3 Feb. 2012. (author)

  5. New Fellows and Honorary Fellow

    Indian Academy of Sciences (India)

    Home; Fellowship. Fellow Profile. Elected: 1954 Honorary. Laue, Prof. Max Theodor Felix von. Nobel Laureate (Physics) - 1914. Date of birth: 9 October 1897. Date of death: 24 April 1960. YouTube; Twitter; Facebook; Blog. Academy News. IAS Logo. 29th Mid-year meeting. Posted on 19 January 2018. The 29th Mid-year ...

  6. Discovery and development of x-ray diffraction

    Science.gov (United States)

    Jeong, Yeuncheol; Yin, Ming; Datta, Timir

    2013-03-01

    In 1912 Max Laue at University of Munich reasoned x-rays to be short wavelength electromagnetic waves and figured interference would occur when scattered off crystals. Arnold Sommerfeld, W. Wien, Ewald and others, raised objections to Laue's idea, but soon Walter Friedrich succeeded in recording x-ray interference patterns off copper sulfate crystals. But the Laue-Ewald's 3-dimensional formula predicted excess spots. Fewer spots were observed. William Lawrence Bragg then 22 year old studying at Cambridge University heard the Munich results from father William Henry Brag, physics professor at Univ of Leeds. Lawrence figured the spots are 2-d interference of x-ray wavelets reflecting off successive atomic planes and derived a simple eponymous equation, the Bragg equation d*sin(theta) = n*lamda. 1913 onward the Braggs dominated the crystallography. Max Laue was awarded the physics Nobel in 1914 and the Braggs shared the same in 1915. Starting with Rontgen's first ever prize in 1901, the importance of x-ray techniques is evident from the four out of a total 16 physics Nobels between 1901-1917. We will outline the historical back ground and importance of x-ray diffraction giving rise to techniques that even in 2013, remain work horses in laboratories all over the globe.

  7. Annual Report 2000

    International Nuclear Information System (INIS)

    2000-01-01

    The Institut Laue-Langevin (ILL) is an international research center using neutrons to probe the microscopic structure and dynamics of a broad range of materials. This annual report presents the ILL activities in 2000: the scientific highlights, the Millennium programme and the new developments, the workshops organized by the ILL, the experimental programme and the publications. (A.L.B.)

  8. Transmutation and neutron flux studies with fission chambers in the MEGAPIE target

    International Nuclear Information System (INIS)

    Chabod, S.; Foucher, Y.; Letourneau, A.; Marie, F.; Toussaint, J.C.; Blandin, Ch.; Chartier, F.; Fioni, G.

    2005-01-01

    Eight fission micro chambers will be inserted inside the central rod of the 1 MW liquid Pb-Bi MEGAPIE target in order to study the transmutation of two major actinides and to measure the neutron flux at a level of 5%. These chambers were developed for high neutron fluxes and tested at Laue Langevin Institute. (authors)

  9. The neutron spin-echo spectrometer: a new high resolution technique in neutron scattering

    International Nuclear Information System (INIS)

    Nicholson, L.K.

    1981-01-01

    The neutron spin-echo (NSE) spectrometer provides the highest energy resolution available in neutron scattering experiments. The article describes the principles behind the first NSE spectrometer (at the Institute Laue-Langevin, Grenoble, France) and, as an example of one of its applications, some recent results on polymer chain dynamics are presented. (author)

  10. Aharonov-Bohm and gravity experiments with the very-cold-neutron interferometer

    CERN Document Server

    Zouw, G V D; Felber, J; Gähler, R; Geltenbort, P; Zeilinger, Anton

    2000-01-01

    We report on the specific techniques associated with experiments with the interferometer for very-cold neutrons at the Institute Laue-Langevin (ILL). Two recent experiments are presented: one to measure the gravitational phase shift to high precision and one to demonstrate the non-dispersivity of the scalar Aharonov-Bohm effect for neutrons.

  11. Rotational coherence spectroscopy at FLASH. Toward dynamic studies in nanosuperfluids

    Energy Technology Data Exchange (ETDEWEB)

    Kickermann, Andreas

    2013-07-15

    The field of molecular physics, which is focusing on molecular motion in the transition states of physical, chemical, and biological changes, is a wide-spread research area. It strives to reveal the structural and functional properties of molecules, the chemical bonds between atoms and the time evolution. Many processes occurring in nature upon electronic excitation proceed on the ultrafast femtosecond timescale and can be triggered by modern ultrashort femtosecond-laser sources under laboratory conditions. In the present thesis pump-probe studies were performed to follow molecular motion using ultrashort light pulses in the nanometer wavelength range provided by an XUV freeelectron laser (FEL). In detail, alignment of molecular species in space under field-free conditions was investigated. In the specific case of rotational wave packets in molecules the rotational dynamics shows characteristic temporal features, which contain a wealth of information on molecular structure and give insight into molecular coupling mechanisms, i.e. rotational constants and transition frequencies. Within this thesis, Rotational Coherence Spectroscopy (RCS) reveals wave-packet motion observed by subsequent Coulomb explosion of Raman excited carbon monoxide, which results in a time-dependent asymmetry of spatial fragmentation patterns. With the method presented here, the time resolution to elucidate the fast dynamics of strong couplings can be pushed toward a single rotational period even for the fastest rotors. This is due to large pump-probe delays with small subpicosecond step size. This kind of spectroscopy can also be expanded to molecular species, which are not accessible by other powerful spectroscopic methods, such as Fourier-transform microwave spectroscopy (FTMW). Furthermore, it allows to measure weak molecular couplings on a long timescale (large pump-probe delays), e.g. couplings of molecules in a solution or molecules dissolved in quantum fluids. This is valuable to

  12. Rotational coherence spectroscopy at FLASH. Toward dynamic studies in nanosuperfluids

    International Nuclear Information System (INIS)

    Kickermann, Andreas

    2013-07-01

    The field of molecular physics, which is focusing on molecular motion in the transition states of physical, chemical, and biological changes, is a wide-spread research area. It strives to reveal the structural and functional properties of molecules, the chemical bonds between atoms and the time evolution. Many processes occurring in nature upon electronic excitation proceed on the ultrafast femtosecond timescale and can be triggered by modern ultrashort femtosecond-laser sources under laboratory conditions. In the present thesis pump-probe studies were performed to follow molecular motion using ultrashort light pulses in the nanometer wavelength range provided by an XUV freeelectron laser (FEL). In detail, alignment of molecular species in space under field-free conditions was investigated. In the specific case of rotational wave packets in molecules the rotational dynamics shows characteristic temporal features, which contain a wealth of information on molecular structure and give insight into molecular coupling mechanisms, i.e. rotational constants and transition frequencies. Within this thesis, Rotational Coherence Spectroscopy (RCS) reveals wave-packet motion observed by subsequent Coulomb explosion of Raman excited carbon monoxide, which results in a time-dependent asymmetry of spatial fragmentation patterns. With the method presented here, the time resolution to elucidate the fast dynamics of strong couplings can be pushed toward a single rotational period even for the fastest rotors. This is due to large pump-probe delays with small subpicosecond step size. This kind of spectroscopy can also be expanded to molecular species, which are not accessible by other powerful spectroscopic methods, such as Fourier-transform microwave spectroscopy (FTMW). Furthermore, it allows to measure weak molecular couplings on a long timescale (large pump-probe delays), e.g. couplings of molecules in a solution or molecules dissolved in quantum fluids. This is valuable to

  13. Theoretical study of the femtosecond-resolved photoelectron spectrum of the NO molecule

    International Nuclear Information System (INIS)

    Meng Qingtian; Yang Guanghui; Sun Hailin; Han Keli; Lou Nanquan

    2003-01-01

    The effect of laser fields on the NO interaction potentials is obtained by the calculation of time-resolved photoelectron spectrum (TRPES) using the time-dependent wave-packet method. The calculation not only shows that the overlap of the pump-probe pulses makes some NO molecular 'invisible' states visible, but also that the coupling strength and the positions of relevant curves change on increasing the laser intensity. These changed potentials affect their dynamical behavior and influence the shape and position of each peak in TRPES. That the coupling strength of relevant potentials can be changed by the field-matter interaction is consistent with our ab initio calculations

  14. Spin dynamics in bulk CdTe at room temperature

    International Nuclear Information System (INIS)

    Nahalkova, P.; Nemec, P.; Sprinzl, D.; Belas, E.; Horodysky, P.; Franc, J.; Hlidek, P.; Maly, P.

    2006-01-01

    In this paper, we report on the room temperature dynamics of spin-polarized carriers in undoped bulk CdTe. Platelets of CdTe with different concentration of preparation-induced dislocations were prepared by combining the mechanical polishing and chemical etching. Using the polarization-resolved pump-probe experiment in transmission geometry, we have observed a systematic decrease of both the signal polarization and the electron spin dephasing time (from 52 to 36 ps) with the increased concentration of defects. We have suggested that the Elliot-Yafet mechanism might be the dominant spin dephasing mechanism in platelets of CdTe at room temperature

  15. Inefficiency of intervalley transfer in narrow InGaAs/AlAsSb quantum wells

    International Nuclear Information System (INIS)

    Tribuzy, C.V.B.; Ohser, S.; Priegnitz, M.; Winnerl, S.; Schneider, H.; Helm, M.; Neuhaus, J.; Dekorsy, T.; Biermann, K.; Kuenzel, H.

    2008-01-01

    By using femtosecond pump-probe spectroscopy we investigate the intersubband relaxation dynamics in narrow InGaAs/AlAsSb quantum wells. A biexponential behavior is an indication of intervalley scattering, which is, however, much slower than known from bulk material. This may be the reason why quantum cascade lasers at wavelengths as short as 3 μm are actually functioning In addition, when pumping slightly below resonance we observe an induced transient absorption, which can be interpreted in terms of electron heating within the first subband. (copyright 2008 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  16. Ultrafast single-molecule photonics: Excited state dynamics in coherently coupled complexes

    International Nuclear Information System (INIS)

    Hernando, Jordi; Hoogenboom, Jacob; Dijk, Erik van; Garcia-Parajo, Maria; Hulst, Niek F. van

    2008-01-01

    We present a single-molecule study on femtosecond dynamics in multichromophoric systems, combining fs pump-probe, emission-spectra and fluorescence-lifetime analysis. The ultrafast fs approach gives direct information on the initial exciton dynamics after excitation. The lifetime data show superradiance, a direct measure for the extent of the coherent coupling and static disorder. The spectra finally reveal the role of exciton-phonon coupling. At the single-molecule level a wide range of exciton delocalization lengths and energy redistribution times is revealed

  17. Ultrafast single-molecule photonics: Excited state dynamics in coherently coupled complexes

    Energy Technology Data Exchange (ETDEWEB)

    Hernando, Jordi [Dept. de Quimica, Universitat Autonoma Barcelona, 08193 Cerdanyola del Valles (Spain); Hoogenboom, Jacob [ICFO-Institut de Ciencies Fotoniques, Mediterranean Technology Park, 08860 Castelldefels, Barcelona (Spain); Dijk, Erik van [Applied Optics Group, MESA Institute for Nanotechnology, University of Twente, 7500AE Enschede (Netherlands); Garcia-Parajo, Maria [IBEC-Institute of BioEngineering of Catalunya, 08028 Barcelona (Spain); ICREA-Institucio Catalana de Recerca i Estudis Avancats, 08015 Barcelona (Spain); Hulst, Niek F. van [ICFO-Institut de Ciencies Fotoniques, Mediterranean Technology Park, 08860 Castelldefels, Barcelona (Spain) and ICREA-Institucio Catalana de Recerca i Estudis Avancats, 08015 Barcelona (Spain)], E-mail: Niek.vanHulst@ICFO.es

    2008-05-15

    We present a single-molecule study on femtosecond dynamics in multichromophoric systems, combining fs pump-probe, emission-spectra and fluorescence-lifetime analysis. The ultrafast fs approach gives direct information on the initial exciton dynamics after excitation. The lifetime data show superradiance, a direct measure for the extent of the coherent coupling and static disorder. The spectra finally reveal the role of exciton-phonon coupling. At the single-molecule level a wide range of exciton delocalization lengths and energy redistribution times is revealed.

  18. Slowing hot-carrier relaxation in graphene using a magnetic field

    Science.gov (United States)

    Plochocka, P.; Kossacki, P.; Golnik, A.; Kazimierczuk, T.; Berger, C.; de Heer, W. A.; Potemski, M.

    2009-12-01

    A degenerate pump-probe technique is used to investigate the nonequilibrium carrier dynamics in multilayer graphene. Two distinctly different dynamics of the carrier relaxation are observed. A fast relaxation (˜50fs) of the carriers after the initial effect of phase-space filling followed by a slower relaxation (˜4ps) due to thermalization. Both relaxation processes are less efficient when a magnetic field is applied at low temperatures which is attributed to the suppression of the electron-electron Auger scattering due to the nonequidistant Landau-level spacing of the Dirac fermions in graphene.

  19. Subpicosecond gain dynamics in GaAlAs laser diodes

    Energy Technology Data Exchange (ETDEWEB)

    Kesler, M.P.; Ippen, E.P.

    1987-11-30

    Ultrafast gain dynamics in GaAlAs diode amplifiers have been studied using 100 fs optical pulses. Pulse propagation through the amplifier resulted in temporal broadening and pulse shaping due to both gain saturation and material dispersion. Pump-probe experiments indicate the presence of two processes contributing to the gain dynamics but give no evidence of spectral hole burning. A dynamic carrier heating model is presented to explain all of the observed gain nonlinearities, and the implications of our results on the dynamic response of laser diodes are discussed.

  20. Femtosecond Nonlinearities in Indium Gallium Arsenic Phosphide Diode Lasers

    Science.gov (United States)

    Hall, Katherine Lavin

    Semiconductor optical amplifiers are receiving increasing attention for possible applications to broadband optical communication and switching systems. In this thesis we report the results of an extensive experimental study of the ultrafast gain and refractive index nonlinearities in 1.5 μm InGaAsP laser diode amplifiers. The temporal resolution afforded by the femtosecond optical pulses used in these experiments allows us to study carrier interactions with other carriers as well as carrier interactions with the lattice. The 100-200 fs optical pulses used in the pump -probe experiments are generated by an Additive Pulse Modelocked color center laser. The measured group velocity dispersion in the diodes ranged from -0.6 to -0.95 mu m^{-1 }. Differences in the group velocity for TE - and TM-polarized pulses suggested that cross-polarized pump-probe pulses walk off from each other in the diode. This walk-off can diminish the time resolution of some experiments. A novel heterodyne pump-probe technique was developed to distinguish collinear, copolarized, pump and probe pulses that were nominally at the same wavelength. Comparing cross-polarized and copolarized pump-probe results yielded new information about the physical mechanisms responsible for nonlinear gain in the diodes. We observed a gain compression across the entire bandwidth of the diode, associated with carrier heating. The hot carrier distribution cooled back to the lattice temperature with a 0.6 to 1.0 ps time constant, depending on the device structure. In addition, we observed a 0.1 to 0.25 ps delay in onset of carrier heating. Large gain compression due to two photon absorption was also observed. A small portion of the nonlinear gain is attributed to spectral hole burning. Pulsewidth-dependent output saturation energies were explained by a rate equation model that included the effect of carrier heating. Measurements of pump-induced probe phase changes revealed index nonlinearities due to delayed carrier

  1. Excitation energy transfer from the bacteriochlorophyll Soret band to carotenoids in the LH2 light-harvesting complex from Ectothiorhodospira haloalkaliphila is negligible.

    Science.gov (United States)

    Razjivin, A P; Lukashev, E P; Kompanets, V O; Kozlovsky, V S; Ashikhmin, A A; Chekalin, S V; Moskalenko, A A; Paschenko, V Z

    2017-09-01

    Pathways of intramolecular conversion and intermolecular electronic excitation energy transfer (EET) in the photosynthetic apparatus of purple bacteria remain subject to debate. Here we experimentally tested the possibility of EET from the bacteriochlorophyll (BChl) Soret band to the singlet S 2 level of carotenoids using femtosecond pump-probe measurements and steady-state fluorescence excitation and absorption measurements in the near-ultraviolet and visible spectral ranges. The efficiency of EET from the Soret band of BChl to S 2 of the carotenoids in light-harvesting complex LH2 from the purple bacterium Ectothiorhodospira haloalkaliphila appeared not to exceed a few percent.

  2. Tailoring of Highly Intense THz Radiation Through High Brightness Electron Beams Longitudinal Manipulation

    Directory of Open Access Journals (Sweden)

    Flavio Giorgianni

    2016-02-01

    Full Text Available The ultra-short electron beams, produced through the velocity bunching compression technique at the SPARC_LAB test Facility (Frascati, Italy, are used to produce Coherent Transition Radiation in the terahertz (THz range. This paper reports on the main features of this THz source, which have a spectral coverage up to 5 THz, a pulse duration down to 100 fs, and an energy per pulse on the order of tens of μJ. These figures of merits open the possibility to apply this source for nonlinear and THz pump-probe experiments in Solid-State Physics and material science.

  3. Correlated terahertz acoustic and electromagnetic emission in dynamically screened InGaN/GaN quantum wells

    DEFF Research Database (Denmark)

    van Capel, P. J. S.; Turchinovich, Dmitry; Porte, Henrik

    2011-01-01

    signals and THz electromagnetic radiation signals demonstrates that transient strain generation in InGaN/GaN MQWs is correlatedwith electromagnetic THz generation, and both types of emission find their origin in ultrafast dynamical screening of the built-in piezoelectric field in the MQWs. The measured......We investigate acoustic and electromagnetic emission from optically excited strained piezoelectric In0.2Ga0.8N/GaN multiple quantum wells (MQWs), using optical pump-probe spectroscopy, time-resolved Brillouin scattering, and THz emission spectroscopy. A direct comparison of detected acoustic...

  4. Past, Present and Future Aspects of Laser-Based Synchronization at FLASH

    OpenAIRE

    Schulz, Sebastian; Bousonville, Michael; Steffen, Bernd; Sydlo, Cezary; Zummack, Falco; Kozak, Tomasz; Predki, Pawel; Kuhl, Alexander; Czwalinna, Marie Kristin; Felber, Matthias; Heuer, Michael; Lamb, Thorsten; Mueller, Jost; Peier, Peter; Ruzin, Sergej

    2013-01-01

    Free-electron lasers, like FLASH and the upcoming European XFEL, are capable of producing XUV and X-ray pulses of a few femtoseconds duration. For time-resolved pump-probe experiments and the externally seeded operation mode it is crucial not only to stabilize the arrival time of the electron bunches, but also to achieve a synchronization accuracy of external lasers on the same timescale. This can only be realized with a laser-based synchronization infrastructure. At FLASH, a periodic femtose...

  5. High speed systems for time-resolved experiments with synchrotron radiation

    Science.gov (United States)

    Koziol, Anna; Maj, Piotr

    2018-02-01

    The UFXC32k is a single photon counting hybrid pixel detector with 75 μm pixel pitch. It was designed to cope with high X-ray intensities and therefore it is a very good candiate for synchrotron applications. In order to use this detector in an application, a dedicated setup must be designed and built allowing proper operation of the detector within the experiment. The paper presents two setups built for the purpose of Pump-Probe-Probe experiments at the Synchrotron SOLEIL and XPCS experiments at the APS.

  6. Slow Noncollinear Coulomb Scattering in the Vicinity of the Dirac Point in Graphene.

    Science.gov (United States)

    König-Otto, J C; Mittendorff, M; Winzer, T; Kadi, F; Malic, E; Knorr, A; Berger, C; de Heer, W A; Pashkin, A; Schneider, H; Helm, M; Winnerl, S

    2016-08-19

    The Coulomb scattering dynamics in graphene in energetic proximity to the Dirac point is investigated by polarization resolved pump-probe spectroscopy and microscopic theory. Collinear Coulomb scattering rapidly thermalizes the carrier distribution in k directions pointing radially away from the Dirac point. Our study reveals, however, that, in almost intrinsic graphene, full thermalization in all directions relying on noncollinear scattering is much slower. For low photon energies, carrier-optical-phonon processes are strongly suppressed and Coulomb mediated noncollinear scattering is remarkably slow, namely on a ps time scale. This effect is very promising for infrared and THz devices based on hot carrier effects.

  7. Ultrashort hard x-ray pulses generated by 90 degrees Thomson scattering

    International Nuclear Information System (INIS)

    Chin, A.H.; Schoenlein, R.W.; Glover, T.E.

    1997-01-01

    Ultrashort x-ray pulses permit observation of fast structural dynamics in a variety of condensed matter systems. The authors have generated 300 femtosecond, 30 keV x-ray pulses by 90 degrees Thomson scattering between femtosecond laser pulses and relativistic electrons. The x-ray and laser pulses are synchronized on a femtosecond time scale, an important prerequisite for ultrafast pump-probe spectroscopy. Analysis of the x-ray beam properties also allows for electron bunch characterization on a femtosecond time scale

  8. Liquid Carbon Reflectivity at 19 nm

    Directory of Open Access Journals (Sweden)

    Riccardo Mincigrucci

    2015-01-01

    Full Text Available We hereby report on a pump-probe reflectivity experiment conducted on amorphous carbon, using a 780 nm laser as a pump and a 19 nm FEL emission as probe. Measurements were performed at 50 degrees with respect to the surface normal to have an un-pumped reflectivity higher than 0.5%. A sub-10 fs time synchronization error could be obtained exploiting the nearly jitter-free capabilities of FERMI. EUV FEL-based experiments open the way to study the behaviour of a liquid carbon phase being unaffected by plasma screening.

  9. Laser spectroscopic visualization of hydrogen bond motions in liquid water

    Science.gov (United States)

    Bratos, S.; Leicknam, J.-Cl.; Pommeret, S.; Gallot, G.

    2004-12-01

    Ultrafast pump-probe experiments are described permitting a visualization of molecular motions in diluted HDO/D 2O solutions. The experiments were realized in the mid-infrared spectral region with a time resolution of 150 fs. They were interpreted by a careful theoretical analysis, based on the correlation function approach of statistical mechanics. Combining experiment and theory, stretching motions of the OH⋯O bonds as well as HDO rotations were 'filmed' in real time. It was found that molecular rotations are the principal agent of hydrogen bond breaking and making in water. Recent literatures covering the subject, including molecular dynamics simulations, are reviewed in detail.

  10. Innovation: study of 'ultra-short' time reactions

    International Nuclear Information System (INIS)

    Anon.

    2001-01-01

    This short article presents the new Elyse facility of Orsay-Paris 11 university for the study of ultra-short chemical and biochemical phenomena. Elyse uses the 'pump-probe' technique which consists in two perfectly synchronized electron and photon pulses. It comprises a 3 to 9 MeV electron accelerator with a HF gun photo-triggered with a laser. Elyse can initiate reactions using ultra-short electron pulses (radiolysis) or ultra-short photon pulses (photolysis). (J.S.)

  11. Time-dependent B-spline R-matrix approach to double ionization of atoms by XUV laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Guan Xiaoxu; Zatsarinny, Oleg; Bartschat, Klaus [Department of Physics and Astronomy, Drake University, Des Moines, Iowa 50311 (United States); Noble, Clifford J [Computational Science and Engineering Department, Daresbury Laboratory, Warrington WA4 4AD (United Kingdom); Schneider, Barry I, E-mail: xiaoxu.guan@drake.ed, E-mail: klaus.bartschat@drake.ed, E-mail: bschneid@nsf.go [Physics Division, National Science Foundation, Arlington, Virgina 22230 (United States)

    2009-11-01

    We present an ab initio and non-perturbative time-dependent approach to the problem of double ionization of a general atom driven by intense XUV laser pulses. After using a highly flexible B-spline R-matrix method to generate field-free Hamiltonian and electric dipole matrices, the initial state is propagated in time using an efficient Arnoldi-Lanczos scheme. Example results for momentum and energy distributions of the two outgoing electrons in two-color pump-probe processes of He are presented.

  12. A time-dependent B-spline R-matrix approach to double ionization of atoms by XUV laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Guan Xiaoxu; Zatsarinny, O; Noble, C J; Bartschat, K [Department of Physics and Astronomy, Drake University, Des Moines, IA 50311 (United States); Schneider, B I [Physics Division, National Science Foundation, Arlington, Virgina 22230 (United States)], E-mail: xiaoxu.guan@drake.edu, E-mail: oleg.zatsarinny@drake.edu, E-mail: cjn@maxnet.co.nz, E-mail: klaus.bartschat@drake.edu, E-mail: bschneid@nsf.gov

    2009-07-14

    We present an ab initio and non-perturbative time-dependent approach to the problem of double ionization of a general atom driven by intense XUV laser pulses. After using a highly flexible B-spline R-matrix method to generate field-free Hamiltonian and electric dipole matrices, the initial state is propagated in time using an efficient Arnoldi-Lanczos scheme. Test calculations for double ionization of He by a single laser pulse yield good agreement with benchmark results obtained with other methods. The method is then applied to two-colour pump-probe processes, for which momentum and energy distributions of the two outgoing electrons are presented.

  13. Reversible ultrafast melting in bulk CdSe

    International Nuclear Information System (INIS)

    Wu, Wenzhi; He, Feng; Wang, Yaguo

    2016-01-01

    In this work, transient reflectivity changes in bulk CdSe have been measured with two-color femtosecond pump-probe spectroscopy under a wide range of pump fluences. Three regions of reflectivity change with pump fluences have been consistently revealed for excited carrier density, coherent phonon amplitude, and lattice temperature. For laser fluences from 13 to 19.3 mJ/cm 2 , ultrafast melting happens in first several picoseconds. This melting process is purely thermal and reversible. A complete phase transformation in bulk CdSe may be reached when the absorbed laser energy is localized long enough, as observed in nanocrystalline CdSe

  14. Electrical detection of spin current and spin relaxation in nonmagnetic semiconductors

    International Nuclear Information System (INIS)

    Miah, M Idrish

    2008-01-01

    We report an electrical method for the detection of spin current and spin relaxation in nonmagnetic semiconductors. Optically polarized spins are dragged by an electric field in GaAs. We use the anomalous Hall effect for the detection of spin current and spin relaxation. It is found that the effect depends on the electric field and doping density as well as on temperature, but not on the excitation power. A calculation for the effect is performed using the measured spin polarization by a pump-probe experiment. The results are also discussed in comparison with a quantitative evaluation of the spin lifetimes of the photogenerated electrons under drift in GaAs

  15. Electrical detection of spin current and spin relaxation in nonmagnetic semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Miah, M Idrish [Nanoscale Science and Technology Centre and School of Biomolecular and Physical Sciences, Griffith University, Nathan, Brisbane, QLD 4111 (Australia); Department of Physics, University of Chittagong, Chittagong 4331 (Bangladesh)], E-mail: m.miah@griffith.edu.au

    2008-09-21

    We report an electrical method for the detection of spin current and spin relaxation in nonmagnetic semiconductors. Optically polarized spins are dragged by an electric field in GaAs. We use the anomalous Hall effect for the detection of spin current and spin relaxation. It is found that the effect depends on the electric field and doping density as well as on temperature, but not on the excitation power. A calculation for the effect is performed using the measured spin polarization by a pump-probe experiment. The results are also discussed in comparison with a quantitative evaluation of the spin lifetimes of the photogenerated electrons under drift in GaAs.

  16. Electron small polarons and their mobility in iron (oxyhydr)oxide nanoparticles

    DEFF Research Database (Denmark)

    Katz, Jordan E; Zhang, Xiaoyi; Attenkofer, Klaus

    2012-01-01

    Electron mobility within iron (oxyhydr)oxides enables charge transfer between widely separated surface sites. There is increasing evidence that this internal conduction influences the rates of interfacial reactions and the outcomes of redox-driven phase transformations of environmental interest....... To determine the links between crystal structure and charge-transport efficiency, we used pump-probe spectroscopy to study the dynamics of electrons introduced into iron(III) (oxyhydr)oxide nanoparticles via ultrafast interfacial electron transfer. Using time-resolved x-ray spectroscopy and ab initio...

  17. Femtosecond Synchronization of Laser Systems for the LCLS

    International Nuclear Information System (INIS)

    Byrd, John; Doolittle, Lawrence; Huang, Gang; Staples, John; Wilcox, Russell; Arthur, John; Frisch, Josef; White, William

    2012-01-01

    The scientific potential of femtosecond x-ray pulses at linac-driven free-electron lasers such as the Linac Coherent Light Source is tremendous. Time-resolved pump-probe experiments require a measure of the relative arrival time of each x-ray pulse with respect to the experimental pump laser. An optical timing system based on stabilized fiber links has been developed for the LCLS to provide this synchronization. Preliminary results show synchronization of the installed stabilized links at the sub-20-femtosecond level. We present details of the implementation at LCLS and potential for future development.

  18. Picosecond absorption relaxation measured with nanosecond laser photoacoustics.

    Science.gov (United States)

    Danielli, Amos; Favazza, Christopher P; Maslov, Konstantin; Wang, Lihong V

    2010-10-18

    Picosecond absorption relaxation-central to many disciplines-is typically measured by ultrafast (femtosecond or picosecond) pump-probe techniques, which however are restricted to optically thin and weakly scattering materials or require artificial sample preparation. Here, we developed a reflection-mode relaxation photoacoustic microscope based on a nanosecond laser and measured picosecond absorption relaxation times. The relaxation times of oxygenated and deoxygenated hemoglobin molecules, both possessing extremely low fluorescence quantum yields, were measured at 576 nm. The added advantages in dispersion susceptibility, laser-wavelength availability, reflection sensing, and expense foster the study of natural-including strongly scattering and nonfluorescent-materials.

  19. Ultrafast dynamics in ZnO/ZnMgO multiple quantum wells

    International Nuclear Information System (INIS)

    Wen, X M; Davis, J A; McDonald, D; Dao, L V; Hannaford, P; Coleman, V A; Tan, H H; Jagadish, C; Koike, K; Sasa, S; Inoue, M; Yano, M

    2007-01-01

    We have investigated carrier relaxation and exciton recombination dynamics in ZnO/ZnMgO multiple quantum wells using femtosecond pump-probe techniques at room temperature. For a probe energy above the band gap, the hot carriers exhibit an effective relaxation by longitudinal optical phonon scattering with a cooling time of 700-850 fs. By detecting the emission near the band-gap, a longer decay time of a few picoseconds was observed which is attributed to acoustic phonon scattering. As the probe energy is decreased further, the decay time continues to increase due to the transitions of exciton recombination or localized carrier recombination

  20. Ultra-short time sciences. From the atto-second to the peta-watts

    International Nuclear Information System (INIS)

    2000-01-01

    This book presents the recent advances in the scientific and technical domains linked with ultra-short time physics. It deals first with the conceptual and technological aspects of ultra-intense and ultra-brief lasers. Then, it describes the different domains of research (atoms, molecules and aggregates; gaseous phase dynamics using the pump-probe technique; femto-chemistry in dense phase; condensed matter; plasma physics; consistent control; aerosols; functional femto-biology) and the different domains of application (medical diagnosis; ophthalmology; telecommunications; technological and industrial developments). A last part is devoted to the teaching of ultra-short time sciences. (J.S.)

  1. Effect of quantum interference on the optical properties of a three-level V-type atomic system beyond the two-photon resonance condition

    Energy Technology Data Exchange (ETDEWEB)

    Mousavi, S M; Safari, L; Mahmoudi, M [Physics Department, Zanjan University, PO Box 45195-313, Zanjan (Iran, Islamic Republic of); Sahrai, M, E-mail: sahrai@tabrizu.ac.i [Research Institute for Applied Physics and Astronomy, University of Tabriz, Tabriz (Iran, Islamic Republic of)

    2010-08-28

    The effect of quantum interference on the optical properties of a pumped-probe three-level V-type atomic system is investigated. The probe absorption, dispersion, group index and optical bistability beyond the two-photon resonance condition are discussed. It is found that the optical properties of a medium in the frequency of the probe field, in general, are phase independent. The phase dependence arises from a scattering of the coupling field into the probe field at a frequency which in general differs from the probe field frequency. It is demonstrated that beyond the two-photon resonance condition the phase sensitivity of the medium will disappear.

  2. Modeling the high-energy electronic state manifold of adenine: Calibration for nonlinear electronic spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Nenov, Artur, E-mail: Artur.Nenov@unibo.it; Giussani, Angelo; Segarra-Martí, Javier; Jaiswal, Vishal K. [Dipartimento di Chimica “G. Ciamician,” Università di Bologna, Via Selmi 2, IT-40126 Bologna (Italy); Rivalta, Ivan [Université de Lyon, CNRS, Institut de Chimie de Lyon, École Normale Supérieure de Lyon, 46 Allée d’Italie, F-69364 Lyon Cedex 07 (France); Cerullo, Giulio [Dipartimento di Fisica, Politecnico di Milano, IFN-CNR, Piazza Leonardo Da Vinci 32, IT-20133 Milano (Italy); Mukamel, Shaul [Department of Chemistry, University of California, Irvine, California 92697-2025 (United States); Garavelli, Marco, E-mail: marco.garavelli@unibo.it, E-mail: marco.garavelli@ens-lyon.fr [Dipartimento di Chimica “G. Ciamician,” Università di Bologna, Via Selmi 2, IT-40126 Bologna (Italy); Université de Lyon, CNRS, Institut de Chimie de Lyon, École Normale Supérieure de Lyon, 46 Allée d’Italie, F-69364 Lyon Cedex 07 (France)

    2015-06-07

    Pump-probe electronic spectroscopy using femtosecond laser pulses has evolved into a standard tool for tracking ultrafast excited state dynamics. Its two-dimensional (2D) counterpart is becoming an increasingly available and promising technique for resolving many of the limitations of pump-probe caused by spectral congestion. The ability to simulate pump-probe and 2D spectra from ab initio computations would allow one to link mechanistic observables like molecular motions and the making/breaking of chemical bonds to experimental observables like excited state lifetimes and quantum yields. From a theoretical standpoint, the characterization of the electronic transitions in the visible (Vis)/ultraviolet (UV), which are excited via the interaction of a molecular system with the incoming pump/probe pulses, translates into the determination of a computationally challenging number of excited states (going over 100) even for small/medium sized systems. A protocol is therefore required to evaluate the fluctuations of spectral properties like transition energies and dipole moments as a function of the computational parameters and to estimate the effect of these fluctuations on the transient spectral appearance. In the present contribution such a protocol is presented within the framework of complete and restricted active space self-consistent field theory and its second-order perturbation theory extensions. The electronic excited states of adenine have been carefully characterized through a previously presented computational recipe [Nenov et al., Comput. Theor. Chem. 1040–1041, 295-303 (2014)]. A wise reduction of the level of theory has then been performed in order to obtain a computationally less demanding approach that is still able to reproduce the characteristic features of the reference data. Foreseeing the potentiality of 2D electronic spectroscopy to track polynucleotide ground and excited state dynamics, and in particular its expected ability to provide

  3. Dynamical interactions between solute and solvent studied by nonlinear infrared spectroscopy

    International Nuclear Information System (INIS)

    Ohta, K.; Tominaga, K.

    2006-01-01

    Interactions between solute and solvent play an important role in chemical reaction dynamics and in many relaxation processes in condensed phases. Recently third-order nonlinear infrared (IR) spectroscopy has shown to be useful to investigate solute-solvent interaction and dynamics of the vibrational transition. These studies provide detailed information on the energy relaxation of the vibrationally excited state, and the time scale and the magnitude of the time correlation functions of the vibrational frequency fluctuations. In this work we have studied vibrational energy relaxation (VER) of solutions and molecular complexes by nonlinear IR spectroscopy, especially IR pump-probe method, to understand the microscopic interactions in liquids. (authors)

  4. Characterization of photo-induced valence tautomerism in a cobalt-dioxolene complex by ultrafast spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Beni, A [Dipartimento di Chimica, Universita di Firenze, via della Lastruccia 3, 50019 Sesto Fiorentino, Florence (Italy); Bogani, L [Dipartimento di Chimica, Universita di Firenze, via della Lastruccia 3, 50019 Sesto Fiorentino, Florence (Italy); Bussotti, L [LENS, Universita di Firenze, Via Nello Carrara 1, 50019 Sesto Fiorentino, Florence (Italy); Dei, A [Dipartimento di Chimica, Universita di Firenze, via della Lastruccia 3, 50019 Sesto Fiorentino, Florence (Italy); Gentili, P L [LENS, Universita di Firenze, Via Nello Carrara 1, 50019 Sesto Fiorentino, Florence (Italy); Righini, R [Dipartimento di Chimica, Universita di Firenze, via della Lastruccia 3, 50019 Sesto Fiorentino, Florence (Italy)

    2005-01-01

    The valence tautomerism of low-spin Co{sup III}(Cat-N-BQ)(Cat-N-SQ) was investigated by means of UV-vis pump-probe transient absorption spectroscopy in chloroform. By exciting the CT transition of the complex at 480 nm, an intramolecular electron transfer process is selectively triggered. The photo-induced charge transfer is pursued by a cascade of two main molecular events characterized by the ultrafast transient absorption spectroscopy: the first gives rise to the metastable high-spin Co{sup II}(Cat-N-BQ){sub 2} that, secondly, reaches the chemical equilibrium with the reactant species.

  5. Characterization of photo-induced valence tautomerism in a cobalt-dioxolene complex by ultrafast spectroscopy

    International Nuclear Information System (INIS)

    Beni, A; Bogani, L; Bussotti, L; Dei, A; Gentili, P L; Righini, R

    2005-01-01

    The valence tautomerism of low-spin Co III (Cat-N-BQ)(Cat-N-SQ) was investigated by means of UV-vis pump-probe transient absorption spectroscopy in chloroform. By exciting the CT transition of the complex at 480 nm, an intramolecular electron transfer process is selectively triggered. The photo-induced charge transfer is pursued by a cascade of two main molecular events characterized by the ultrafast transient absorption spectroscopy: the first gives rise to the metastable high-spin Co II (Cat-N-BQ) 2 that, secondly, reaches the chemical equilibrium with the reactant species

  6. Characterization of photo-induced valence tautomerism in a cobalt-dioxolene complex by ultrafast spectroscopy

    Science.gov (United States)

    Beni, A.; Bogani, L.; Bussotti, L.; Dei, A.; Gentili, P. L.; Righini, R.

    2005-01-01

    The valence tautomerism of low-spin CoIII(Cat-N-BQ)(Cat-N-SQ) was investigated by means of UV-vis pump-probe transient absorption spectroscopy in chloroform. By exciting the CT transition of the complex at 480 nm, an intramolecular electron transfer process is selectively triggered. The photo-induced charge transfer is pursued by a cascade of two main molecular events characterized by the ultrafast transient absorption spectroscopy: the first gives rise to the metastable high-spin CoII(Cat-N-BQ)2 that, secondly, reaches the chemical equilibrium with the reactant species.

  7. All-optical signal processing using InP photonic-crystal nanocavity switches

    DEFF Research Database (Denmark)

    Yu, Yi; Vukovic, Dragana; Heuck, Mikkel

    2014-01-01

    In this paper, we present recent progress in experimental characterization of InP photonic-crystal nanocavity switches. Pump-probe measurements on an InP PhC H0 cavity show large-contrast ultrafast switching at low pulse energy. At large pulse energies, a large resonance shift passing across...... for the joint effects of fast carrier diffusion, slow surface and bulk recombination. Utilizin g the simple InP PhC nanocavity structure, we successfully dem onstrate 10-Gb/s RZ- OOK all-optical modulation with low energy consumption....

  8. Ultrafast Optical Modulation of Second- and Third-Harmonic Generation from Cut-Disk-Based Metasurfaces

    KAUST Repository

    Sartorello, Giovanni

    2016-06-06

    We design and fabricate a metasurface composed of gold cut-disk resonators that exhibits a strong coherent nonlinear response. We experimentally demonstrate all-optical modulation of both second- and third-harmonic signals on a subpicosecond time scale. Pump-probe experiments and numerical models show that the observed effects are due to the ultrafast response of the electronic excitations in the metal under external illumination. These effects pave the way for the development of novel active nonlinear metasurfaces with controllable and switchable coherent nonlinear response. © 2016 American Chemical Society.

  9. Bottom-up excited state dynamics of two cinnamate-based sunscreen filter molecules

    OpenAIRE

    Peperstraete, Yoann; Staniforth, Michael; Baker, Lewis A.; Rodrigues, Natércia D. N.; Cole-Filipiak, Neil C.; Quan, Wen-Dong; Stavros, Vasilios G.

    2016-01-01

    Methyl-E-4-methoxycinnamate (E-MMC) is a model chromophore of the commonly used commercial sunscreen agent, 2- ethylhexyl-E-4-methoxycinnamate (E-EHMC). In an effort to garner a molecular-level understanding of the photoprotection mechanisms in operation with E-EHMC, we have used time-resolved pump-probe spectroscopy to explore E-MMC’s and E-EHMC’s excited state dynamics upon UV-B photoexcitation to the S1 (11ππ*) state in both the gas- and solution-phase. In the gas-phase, our studies sugges...

  10. Chirped-pulse manipulated carrier dynamics in low-temperature molecular-beam-epitaxy grown GaAs

    International Nuclear Information System (INIS)

    Lee, Chao-Kuei; Lin, Yuan-Yao; Lin, Sung-Hui; Lin, Gong-Ru; Pan, Ci-Ling

    2014-01-01

    Chirped pulse controlled carrier dynamics in low-temperature molecular-beam-epitaxy grown GaAs are investigated by degenerate pump-probe technique. Varying the chirped condition of excited pulse from negative to positive increases the carrier relaxation time so as to modify the dispersion and reshape current pulse in time domain. The spectral dependence of carrier dynamics is analytically derived and explained by Shockley-Read Hall model. This observation enables the new feasibility of controlling carrier dynamics in ultrafast optical devices via the chirped pulse excitations

  11. In-line femtosecond common-path interferometer in reflection mode.

    Science.gov (United States)

    Chandezon, J; Rampnoux, J-M; Dilhaire, S; Audoin, B; Guillet, Y

    2015-10-19

    An innovative method to perform femtosecond time-resolved interferometry in reflection mode is proposed. The experiment consists in the combined use of a pump-probe setup and of a fully passive in-line femtosecond common-path interferometer. The originality of this interferometer relies on the use of a single birefringent crystal first to generate a pair of phase-locked pulses and second to recombine them to interfere. As predicted by analytical modeling, this interferometer measures the temporal derivative of the ultrafast changes of the complex optical reflection coefficient of the sample. Working conditions are illustrated through picosecond opto-acoustic experiments on a thin film.

  12. Stability and signatures of biexcitons in carbon nanotubes

    DEFF Research Database (Denmark)

    Pedersen, Thomas Garm; Pedersen, Kjeld; Cornean, Horia Decebal

    2005-01-01

    The linear optical properties of semiconducting carbon nanotubes are dominated by quasi-one-dimensional excitons formed by single electron-hole pairs. Hence, the nonlinear response at high pump levels most likely leads to the formation of exciton complexes involving several electron-hole pairs....... Such complexes would threfore play an important role in e.g. lasing applications. We demonstrate here that the biexciton complex is surprisingly stable for nanotubes in a wide diameter range. Theoretical predictions for the signature of such states in pump-probe spectroscopy are presented....

  13. Laser amplification in excited dielectrics

    DEFF Research Database (Denmark)

    Winkler, Thomas; Haahr-Lillevang, Lasse; Sarpe, Cristian

    2018-01-01

    Wide-bandgap dielectrics such as glasses or water are transparent at visible and infrared wavelengths. This changes when they are exposed to ultrashort and highly intense laser pulses. Different interaction mechanisms lead to the appearance of various transient nonlinear optical phenomena. Using...... these, the optical properties of dielectrics can be controlled from the transparent to the metal-like state. Here we expand this range by a yet unexplored mechanism in excited dielectrics: amplification. In a two-colour pump-probe experiment, we show that a 400nm femtosecond laser pulse is coherently...

  14. Ultra-fast polariton dynamics in an organic microcavity

    Directory of Open Access Journals (Sweden)

    Polli D.

    2013-03-01

    Full Text Available We study an organic semiconductor microcavity operating in the strong-coupling regime using femtosecond pump-probe spectroscopy. By probing the photo-induced absorption bands, we characterize the time-dependent population densities of states in the two polariton branches. We found evidence of a scattering process from the upper-branch cavity polaritons to the exciton reservoir having a rate of (150 fs-1. A slower process similarly populates lower-branch polaritons with a rate of around (3ps-1

  15. Light propagation and interaction observed with electrons

    Energy Technology Data Exchange (ETDEWEB)

    Word, Robert C.; Fitzgerald, J.P.S.; Könenkamp, R., E-mail: rkoe@pdx.edu

    2016-01-15

    We discuss possibilities for a microscopic optical characterization of thin films and surfaces based on photoemission electron microscopy. We show that propagating light with wavelengths across the visible range can readily be visualized, and linear and non-linear materials properties can be evaluated non-invasively with nanometer spatial resolution. While femtosecond temporal resolution can be achieved in pump-probe-type experiments, the interferometric approach presented here has typical image frame times of ~200 fs. - Highlights: • Non-linear photoemission electron micrographs are analyzed. • Optical properties of transparent and metallic thin films are determined. • Light propagation, surface plasmon resonances and energy transfer are discussed.

  16. Observation and control of coherent torsional dynamics in a quinquethiophene molecule.

    Science.gov (United States)

    Cirmi, Giovanni; Brida, Daniele; Gambetta, Alessio; Piacenza, Manuel; Della Sala, Fabio; Favaretto, Laura; Cerullo, Giulio; Lanzani, Guglielmo

    2010-07-28

    By applying femtosecond pump-probe spectroscopy to a substituted quinquethiophene molecule in solution, we observe in the time domain the coherent torsional dynamics that drives planarization of the excited state. Our interpretation is based on numerical modeling of the ground and excited state potential energy surfaces and simulation of wavepacket dynamics, which reveals two symmetric excited state deactivation pathways per oscillation period. We use the acquired knowledge on torsional dynamics to coherently control the excited state population with a pump-dump scheme, exploiting the non-stationary Franck-Condon overlap between ground and excited states.

  17. Electron-spin dynamics in Mn-doped GaAs using time-resolved magneto-optical techniques

    Science.gov (United States)

    Akimov, I. A.; Dzhioev, R. I.; Korenev, V. L.; Kusrayev, Yu. G.; Zhukov, E. A.; Yakovlev, D. R.; Bayer, M.

    2009-08-01

    We study the electron-spin dynamics in p -type GaAs doped with magnetic Mn acceptors by means of time-resolved pump-probe and photoluminescence techniques. Measurements in transverse magnetic fields show a long spin-relaxation time of 20 ns that can be uniquely related to electrons. Application of weak longitudinal magnetic fields above 100 mT extends the spin-relaxation times up to microseconds which is explained by suppression of the Bir-Aronov-Pikus spin relaxation for the electron on the Mn acceptor.

  18. Resonance laser-plasma excitation of coherent terahertz phonons in the bulk of fluorine-bearing crystals under high-intensity femtosecond laser irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Potemkin, F V; Mareev, E I [International Laser Center, M. V. Lomonosov Moscow State University, Moscow (Russian Federation); Khodakovskii, N G [A M Prokhorov General Physics Institute, Russian Academy of Sciences, Moscow (Russian Federation); Mikheev, P M

    2013-08-31

    The dynamics of coherent phonons in fluorine-containing crystals was investigated by pump-probe technique in the plasma production regime. Several phonon modes, whose frequencies are overtones of the 0.38-THz fundamental frequency, were simultaneously observed in a lithium fluoride crystal. Phonons with frequencies of 1 and 0.1 THz were discovered in a calcium fluoride crystal and coherent phonons with frequencies of 1 THz and 67 GHz were observed in a barium fluoride crystal. Furthermore, in the latter case the amplitudes of phonon mode oscillations were found to significantly increase 15 ps after laser irradiation. (interaction of laser radiation with matter)

  19. The temperature dependent amide I band of crystalline acetanilide

    Science.gov (United States)

    Cruzeiro, Leonor; Freedman, Holly

    2013-10-01

    The temperature dependent anomalous peak in the amide I band of crystalline acetanilide is thought to be due to self-trapped states. On the contrary, according to the present model, the anomalous peak comes from the fraction of ACN molecules strongly hydrogen-bonded to a neighboring ACN molecule, and its intensity decreases because, on average, this fraction decreases as temperature increases. This model provides, for the first time, an integrated and theoretically consistent view of the temperature dependence of the full amide I band and a qualitative explanation of some of the features of nonlinear pump-probe experiments.

  20. Coherent Phonon Dynamics in Short-Period InAs/GaSb Superlattices

    OpenAIRE

    Noe, G. T.; Haugan, H. J.; Brown, G. J.; Sanders, G. D.; Stanton, C. J.; Kono, J.

    2011-01-01

    We have performed ultrafast pump-probe spectroscopy studies on a series of InAs/GaSb-based short-period superlattice (SL) samples with periods ranging from 46 \\AA to 71 \\AA. We observe two types of oscillations in the differential reflectivity with fast ($\\sim$ 1- 2 ps) and slow ($\\sim$ 24 ps) periods. The period of the fast oscillations changes with the SL period and can be explained as coherent acoustic phonons generated from carriers photoexcited within the SL. This mode provides an accura...