WorldWideScience

Sample records for single-phase pump model

  1. Single-phase pump model for analysis of LMFBR heat transport systems

    International Nuclear Information System (INIS)

    Madni, I.K.; Cazzoli, E.

    1978-05-01

    A single-phase pump model for transient and steady-state analysis of LMFBR heat transport systems is presented. Fundamental equations of the model are angular momentum balance to determine transient impeller speed and mass balance (including thermal expansion effects) to determine the level of sodium in the pump tank. Pump characteristics are modeled by homologous head and torque relations. All regions of pump operation are represented with reverse rotation allowed. The model also includes option for enthalpy rise calculations and pony motor operation. During steady state, the pump operating speed is determined by matching required head with total load in the circuit. Calculated transient results are presented for pump coastdown and double-ended pipe break accidents. The report examines the influence of frictional torque and specific speed on predicted response for the pump coastdown to natural circulation transient. The results for a double-ended pipe break accident indicate the necessity of including all regions of operation for pump characteristics

  2. Single-phase sodium pump model for LMFBR thermal-hydraulic analysis

    International Nuclear Information System (INIS)

    Madni, I.K.; Cazzoli, E.G.; Agrawal, A.K.

    1979-01-01

    A single-phase, homologous pump model has been developed for simulation of safety-related transients in LMFBR systems. Pump characteristics are modeled by homologous head and torque relations encompassing all regimes of operation. These relations were derived from independent model test results with a centrifugal pump of specific speed equal to 35 (SI units) or 1800 (gpm units), and are used to analyze the steady-state and transient behavior of sodium pumps in a number of LMFBR plants. Characteristic coefficients for the polynomials in all operational regimes are provided in a tabular form. The speed and flow dependence of head is included through solutions of the impeller and coolant dynamic equations. Results show the model to yield excellent agreement with experimental data in sodium for the FFTF prototype pump, and with vendor calculations for the CRBR pump. A sample pipe rupture calculation is also performed to demonstrate the necessity for modeling the complete pump characteristics

  3. Model Based Control of Single-Phase Marine Cooling Systems

    DEFF Research Database (Denmark)

    Hansen, Michael

    2014-01-01

    these systems. Traditionally, control for this type of cooling system has been limited to open-loop control of pumps combined with a couple of local PID controllers for bypass valves to keep critical temperatures within design limits. This research considers improvements in a retrofit framework to the control...... linearization, an H∞-control design is applied to the resulting linear system. Disturbance rejection capabilities and robustness of performance for this control design methodology is compared to a baseline design derived from classical control theory. This shows promising results for the nonlinear robust design......This thesis is concerned with the problem of designing model-based control for a class of single-phase marine cooling systems. While this type of cooling system has been in existence for several decades, it is only recently that energy efficiency has become a focus point in the design and operation...

  4. General single phase wellbore flow model

    Energy Technology Data Exchange (ETDEWEB)

    Ouyang, Liang-Biao; Arbabi, S.; Aziz, K.

    1997-02-05

    A general wellbore flow model, which incorporates not only frictional, accelerational and gravitational pressure drops, but also the pressure drop caused by inflow, is presented in this report. The new wellbore model is readily applicable to any wellbore perforation patterns and well completions, and can be easily incorporated in reservoir simulators or analytical reservoir inflow models. Three dimensionless numbers, the accelerational to frictional pressure gradient ratio R{sub af}, the gravitational to frictional pressure gradient ratio R{sub gf}, and the inflow-directional to accelerational pressure gradient ratio R{sub da}, have been introduced to quantitatively describe the relative importance of different pressure gradient components. For fluid flow in a production well, it is expected that there may exist up to three different regions of the wellbore: the laminar flow region, the partially-developed turbulent flow region, and the fully-developed turbulent flow region. The laminar flow region is located near the well toe, the partially-turbulent flow region lies in the middle of the wellbore, while the fully-developed turbulent flow region is at the downstream end or the heel of the wellbore. Length of each region depends on fluid properties, wellbore geometry and flow rate. As the distance from the well toe increases, flow rate in the wellbore increases and the ratios R{sub af} and R{sub da} decrease. Consequently accelerational and inflow-directional pressure drops have the greatest impact in the toe region of the wellbore. Near the well heel the local wellbore flow rate becomes large and close to the total well production rate, here R{sub af} and R{sub da} are small, therefore, both the accelerational and inflow-directional pressure drops can be neglected.

  5. A Single-Phase Transformerless Inverter With Charge Pump Circuit Concept for Grid-Tied PV Applications

    DEFF Research Database (Denmark)

    Ardashir, Jaber Fallah; Sabahi, Mehran; Hosseini, Seyed Hossein

    2017-01-01

    This paper proposes a new single-phase transformerless photovoltaic (PV) inverter for grid-tied PV systems. The topology is derived from the concept of a charge pump circuit in order to eliminate the leakage current. It is composed of four power switches, two diodes, two capacitors, and an LCL ou...

  6. Modeling of a single-phase photovoltaic inverter

    Energy Technology Data Exchange (ETDEWEB)

    Maris, T.I. [Department of Electrical Engineering, Technological Educational Institute of Chalkida, 334 40 Psachna Evias (Greece); Kourtesi, St. [Hellenic Public Power Corporation S.A., 22 Chalcocondyli Str., 104 32 Athens (Greece); Ekonomou, L. [Hellenic American University, 12 Kaplanon Str., 106 80 Athens (Greece); Fotis, G.P. [National Technical University of Athens, School of Electrical and Computer Engineering, High Voltage Laboratory, 9 Iroon Politechniou St., Zografou, 157 80 Athens (Greece)

    2007-11-06

    The paper presents the design of a single-phase photovoltaic inverter model and the simulation of its performance. Furthermore, the concept of moving real and reactive power after coupling this inverter model with an a.c. source representing the main power distribution grid was studied. Brief technical information is given on the inverter design, with emphasis on the operation of the circuit used. In the technical information section, a description of real and reactive power components is given with special reference to the control of these power components by controlling the power angle or the difference in voltage magnitudes between two voltage sources. This a.c. converted voltage has practical interest, since it is useful for feeding small house appliances. (author)

  7. Equivalence of two models in single-phase multicomponent flow simulations

    KAUST Repository

    Wu, Yuanqing

    2016-02-28

    In this work, two models to simulate the single-phase multicomponent flow in reservoirs are introduced: single-phase multicomponent flow model and two-phase compositional flow model. Because the single-phase multicomponent flow is a special case of the two-phase compositional flow, the two-phase compositional flow model can also simulate the case. We compare and analyze the two models when simulating the single-phase multicomponent flow, and then demonstrate the equivalence of the two models mathematically. An experiment is also carried out to verify the equivalence of the two models.

  8. SINGLE PHASE ANALYTICAL MODELS FOR TERRY TURBINE NOZZLE

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Haihua; Zhang, Hongbin; Zou, Ling; O' Brien, James

    2016-11-01

    All BWR RCIC (Reactor Core Isolation Cooling) systems and PWR AFW (Auxiliary Feed Water) systems use Terry turbine, which is composed of the wheel with turbine buckets and several groups of fixed nozzles and reversing chambers inside the turbine casing. The inlet steam is accelerated through the turbine nozzle and impacts on the wheel buckets, generating work to drive the RCIC pump. As part of the efforts to understand the unexpected “self-regulating” mode of the RCIC systems in Fukushima accidents and extend BWR RCIC and PWR AFW operational range and flexibility, mechanistic models for the Terry turbine, based on Sandia National Laboratories’ original work, has been developed and implemented in the RELAP-7 code to simulate the RCIC system. RELAP-7 is a new reactor system code currently under development with the funding support from U.S. Department of Energy. The RELAP-7 code is a fully implicit code and the preconditioned Jacobian-free Newton-Krylov (JFNK) method is used to solve the discretized nonlinear system. This paper presents a set of analytical models for simulating the flow through the Terry turbine nozzles when inlet fluid is pure steam. The implementation of the models into RELAP-7 will be briefly discussed. In the Sandia model, the turbine bucket inlet velocity is provided according to a reduced-order model, which was obtained from a large number of CFD simulations. In this work, we propose an alternative method, using an under-expanded jet model to obtain the velocity and thermodynamic conditions for the turbine bucket inlet. The models include both adiabatic expansion process inside the nozzle and free expansion process out of the nozzle to reach the ambient pressure. The combined models are able to predict the steam mass flow rate and supersonic velocity to the Terry turbine bucket entrance, which are the necessary input conditions for the Terry Turbine rotor model. The nozzle analytical models were validated with experimental data and

  9. Thermal analysis of hybrid single-phase, two-phase and heat pump thermal control system (TCS) for future spacecraft

    International Nuclear Information System (INIS)

    Lee, S.H.; Mudawar, I.; Hasan, Mohammad M.

    2016-01-01

    Highlights: • Hybrid Thermal Control System (H-TCS) is proposed for future spacecraft. • Thermodynamic performance of H-TCS is examined for different space missions. • Operational modes including single-phase, two-phase and heat pump are explored. • R134a is deemed most appropriate working fluid. - Abstract: An urgent need presently exists to develop a new class of versatile spacecraft capable of conducting different types of missions and enduring varying gravitational and temperature environments, including Lunar, Martian and Near Earth Object (NEOs). This study concerns the spacecraft's Thermal Control System (TCS), which tackles heat acquisition, especially from crew and avionics, heat transport, and ultimate heat rejection by radiation. The primary goal of the study is to explore the design and thermal performance of a Hybrid Thermal Control System (H-TCS) that would satisfy the diverse thermal requirements of the different space missions. The H-TCS must endure both ‘cold’ and ‘hot’ environments, reduce weight and size, and enhance thermodynamic performance. Four different operational modes are considered: single-phase, two-phase, basic heat pump and heat pump with liquid-side, suction-side heat exchanger. A thermodynamic trade study is conducted for six different working fluids to assess important performance parameters including mass flow rate of the working fluid, maximum pressure, radiator area, compressor/pump work, and coefficient of performance (COP). R134a is determined to be most suitable based on its ability to provide a balanced compromise between reducing flow rate and maintaining low system pressure, and a moderate coefficient of performance (COP); this fluid is also both nontoxic and nonflammable, and features zero ozone depletion potential (ODP) and low global warming potential (GWP). It is shown how specific mission stages dictate which mode of operation is most suitable, and this information is used to size the radiator for

  10. A Novel Model Predictive Control for Single-Phase Grid-Connected Photovoltaic Inverters

    DEFF Research Database (Denmark)

    Zangeneh Bighash, Esmaeil; Sadeghzadeh, Seyed Mohammad; Ebrahimzadeh, Esmaeil

    2017-01-01

    Single-phase grid-connected inverters with LCL filter are widely used to connect photovoltaic systems to the utility grid. Among the existing control schemes, predictive control methods are faster and more accurate but also more complicated to implement. Recently, the Model Predictive Control (MPC......) algorithm for single-phase inverter has been presented, where the algorithm implementation is straightforward. In the MPC approach, all switching states are considered in each switching period to achieve the control objectives. However, since the number of switching states in single-phase inverters is small...... vectors. Simulation results show that the proposed approach lead to a lower THD in the injected current combined with fast dynamics. The proposed predictive control has been simulated and implemented on a 1 kW single-phase HERIC (highly efficient and reliable inverter concept) inverter with an LCL filter...

  11. Single-Phase Bundle Flows Including Macroscopic Turbulence Model

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Jun; Yoon, Han Young [KAERI, Daejeon (Korea, Republic of); Yoon, Seok Jong; Cho, Hyoung Kyu [Seoul National University, Seoul (Korea, Republic of)

    2016-05-15

    To deal with various thermal hydraulic phenomena due to rapid change of fluid properties when an accident happens, securing mechanistic approaches as much as possible may reduce the uncertainty arising from improper applications of the experimental models. In this study, the turbulence mixing model, which is well defined in the subchannel analysis code such as VIPRE, COBRA, and MATRA by experiments, is replaced by a macroscopic k-e turbulence model, which represents the aspect of mathematical derivation. The performance of CUPID with macroscopic turbulence model is validated against several bundle experiments: CNEN 4x4 and PNL 7x7 rod bundle tests. In this study, the macroscopic k-e model has been validated for the application to subchannel analysis. It has been implemented in the CUPID code and validated against CNEN 4x4 and PNL 7x7 rod bundle tests. The results showed that the macroscopic k-e turbulence model can estimate the experiments properly.

  12. Modeling and Control of a Single-Phase Marine Cooling System

    DEFF Research Database (Denmark)

    Hansen, Michael; Stoustrup, Jakob; Bendtsen, Jan Dimon

    2013-01-01

    This paper presents two model-based control design approaches for a single-phase marine cooling system. Models are derived from first principles and aim at describing significant system dynamics including nonlinearities and transport delays, while keeping the model complexity low. The two...

  13. DQ reference frame modeling and control of single-phase active power decoupling circuits

    DEFF Research Database (Denmark)

    Tang, Yi; Qin, Zian; Blaabjerg, Frede

    2015-01-01

    Power decoupling circuits can compensate the inherent double line frequency ripple power in single-phase systems and greatly facilitate their dc-link capacitor design. Example applications of power decoupling circuit include photovoltaic, light-emitting diode, fuel cell, and motor drive systems....... This paper presents the dq synchronous reference frame modeling of single-phase power decoupling circuits and a complete model describing the dynamics of dc-link ripple voltage is presented. The proposed model is universal and valid for both inductive and capacitive decoupling circuits, and the input...... of decoupling circuits can be either dependent or independent of its front-end converters. Based on this model, a dq synchronous reference frame controller is designed which allows the decoupling circuit to operate in two different modes because of the circuit symmetry. Simulation and experimental results...

  14. RELAP-7 Progress Report: A Mathematical Model for 1-D Compressible, Single-Phase Flow Through a Branching Junction

    Energy Technology Data Exchange (ETDEWEB)

    Berry, R. A. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2017-08-14

    In the literature, the abundance of pipe network junction models, as well as inclusion of dissipative losses between connected pipes with loss coefficients, has been treated using the incompressible flow assumption of constant density. This approach is fundamentally, physically wrong for compressible flow with density change. This report introduces a mathematical modeling approach for general junctions in piping network systems for which the transient flows are compressible and single-phase. The junction could be as simple as a 1-pipe input and 1-pipe output with differing pipe cross-sectional areas for which a dissipative loss is necessary, or it could include an active component, between an inlet pipe and an outlet pipe, such as a pump or turbine. In this report, discussion will be limited to the former. A more general branching junction connecting an arbitrary number of pipes with transient, 1-D compressible single-phase flows is also presented. These models will be developed in a manner consistent with the use of a general equation of state like, for example, the recent Spline-Based Table Look-up method [1] for incorporating the IAPWS-95 formulation [2] to give accurate and efficient calculations for properties for water and steam with RELAP-7 [3].

  15. Modeling and analysis of variable speed single phase induction motors with iron loss

    International Nuclear Information System (INIS)

    Vaez-Zadeh, S.; Zahedi, B.

    2009-01-01

    Despite their usual low power ratings of single phase induction motors, they consume a considerable part of total motors energy consumption due to their large and ever-increasing quantity. The recent rising of oil prices and environmental crises has fortified the idea of energy saving practices in all applications; particularly in single phase induction motors due to their typical low efficiency. An essential requirement for this practice is the modeling and analysis of machine electrical losses under variable frequency operation. In this paper an improved steady state model of single phase induction motors is derived to investigate major motor characteristics like torque-speed, input power, output power, etc. A special emphasis is placed on accurately representing core losses at variable frequency. The winding currents phase difference is reintroduced as a fundamental motor variable to determine motor performances including losses and efficiency. An advanced computerized motor test setup is designed and built for on-line measurement of motor characteristics at different supply and operating conditions. The extensive experimental results, in good agreement with the simulation results based on the mentioned analysis, confirm the validity of the proposed model.

  16. High Quality Model Predictive Control for Single Phase Grid Connected Photovoltaic Inverters

    DEFF Research Database (Denmark)

    Zangeneh Bighash, Esmaeil; Sadeghzadeh, Seyed Mohammad; Ebrahimzadeh, Esmaeil

    2018-01-01

    Single phase grid-connected inverters with LCL filter are widely used to connect the photovoltaic systems to the utility grid. Among the presented control schemes, predictive control methods are faster and more accurate but are more complex to implement. Recently, the model-predictive control...... is low, the inverter output current has a high total harmonic distortions. In order to reduce the total harmonic distortions of the injected current, this paper presents a high-quality model-predictive control for one of the newest structure of the grid connected photovoltaic inverter, i.e., HERIC...

  17. On Thermodynamics Problems in the Single-Phase-Lagging Heat Conduction Model

    Directory of Open Access Journals (Sweden)

    Shu-Nan Li

    2016-11-01

    Full Text Available Thermodynamics problems for the single-phase-lagging (SPL model have not been much studied. In this paper, the violation of the second law of thermodynamics by the SPL model is studied from two perspectives, which are the negative entropy production rate and breaking equilibrium spontaneously. The methods for the SPL model to avoid the negative entropy production rate are proposed, which are extended irreversible thermodynamics and the thermal relaxation time. Modifying the entropy production rate positive or zero is not enough to avoid the violation of the second law of thermodynamics for the SPL model, because the SPL model could cause breaking equilibrium spontaneously in some special circumstances. As comparison, it is shown that Fourier’s law and the CV model cannot break equilibrium spontaneously by analyzing mathematical energy integral.

  18. POD-Galerkin Model for Incompressible Single-Phase Flow in Porous Media

    KAUST Repository

    Wang, Yi

    2017-01-25

    Fast prediction modeling via proper orthogonal decomposition method combined with Galerkin projection is applied to incompressible single-phase fluid flow in porous media. Cases for different configurations of porous media, boundary conditions and problem scales are designed to examine the fidelity and robustness of the model. High precision (relative deviation 1.0 x 10(-4)% similar to 2.3 x 10(-1)%) and large acceleration (speed-up 880 similar to 98454 times) of POD model are found in these cases. Moreover, the computational time of POD model is quite insensitive to the complexity of problems. These results indicate POD model is especially suitable for large-scale complex problems in engineering.

  19. Multi-scale Modeling of Compressible Single-phase Flow in Porous Media using Molecular Simulation

    KAUST Repository

    Saad, Ahmed Mohamed

    2016-05-01

    In this study, an efficient coupling between Monte Carlo (MC) molecular simulation and Darcy-scale flow in porous media is presented. The cell-centered finite difference method with a non-uniform rectangular mesh were used to discretize the simulation domain and solve the governing equations. To speed up the MC simulations, we implemented a recently developed scheme that quickly generates MC Markov chains out of pre-computed ones, based on the reweighting and reconstruction algorithm. This method astonishingly reduces the required computational time by MC simulations from hours to seconds. In addition, the reweighting and reconstruction scheme, which was originally designed to work with the LJ potential model, is extended to work with a potential model that accounts for the molecular quadrupole moment of fluids with non-spherical molecules such as CO2. The potential model was used to simulate the thermodynamic equilibrium properties for single-phase and two-phase systems using the canonical ensemble and the Gibbs ensemble, respectively. Comparing the simulation results with the experimental data showed that the implemented model has an excellent fit outperforming the standard LJ model. To demonstrate the strength of the proposed coupling in terms of computational time efficiency and numerical accuracy in fluid properties, various numerical experiments covering different compressible single-phase flow scenarios were conducted. The novelty in the introduced scheme is in allowing an efficient coupling of the molecular scale and Darcy scale in reservoir simulators. This leads to an accurate description of the thermodynamic behavior of the simulated reservoir fluids; consequently enhancing the confidence in the flow predictions in porous media.

  20. Analytical Modeling Of The Steinmetz Coefficient For Single-Phase Transformer Eddy Current Loss Prediction

    Directory of Open Access Journals (Sweden)

    T. Aly Saandy

    2015-08-01

    Full Text Available Abstract This article presents to an analytical calculation methodology of the Steinmetz coefficient applied to the prediction of Eddy current loss in a single-phase transformer. Based on the electrical circuit theory the active power consumed by the core is expressed analytically in function of the electrical parameters as resistivity and the geometrical dimensions of the core. The proposed modeling approach is established with the duality parallel series. The required coefficient is identified from the empirical Steinmetz data based on the experimented active power expression. To verify the relevance of the model validations both by simulations with two in two different frequencies and measurements were carried out. The obtained results are in good agreement with the theoretical approach and the practical results.

  1. Modelling of the modified-LLCL-filter-based single-phase grid-tied Aalborg inverter

    DEFF Research Database (Denmark)

    Liu, Zifa; Wu, Huiyun; Liu, Yuan

    2017-01-01

    Owing to less conduction and switching power losses, the recently proposed Aalborg inverter has high efficiency within a wide range of input DC voltage for single-phase DC/AC power conversion. In theory, the conduction power losses can be further decreased, if an LLCL-filter is adopted instead....... In this study, the small signal analysis for the modified-LLCL-filter-based Aalborg inverter is addressed. Through the modelling, it can be proven that compared with the LCL-filter, the modified-LLCL-filter causes no extra control challenge for the Aalborg inverter, and therefore more inductance in the power...... of an LCL-filter for a voltage source inverter, mainly due to the reduced inductance. The Aalborg inverter shows the characteristic of a current source inverter, when working in the `boost' state. Whether the LLCL-filter can meet the control requirement of this type inverter needs to be further explored...

  2. A single-phase model for liquid-feed DMFCs with non-Tafel kinetics

    Science.gov (United States)

    Vera, Marcos

    An isothermal single-phase 3D/1D model for liquid-feed direct methanol fuel cells (DMFC) is presented. Three-dimensional (3D) mass, momentum and species transport in the anode channels and gas diffusion layer is modeled using a commercial, finite-volume based, computational fluid dynamics (CFD) software complemented with user supplied subroutines. The 3D model is locally coupled to a one-dimensional (1D) model accounting for the electrochemical reactions in both the anode and the cathode, which provides a physically sound boundary condition for the velocity and methanol concentration fields at the anode gas diffusion layer/catalyst interface. The 1D model - comprising the membrane-electrode assembly, cathode gas diffusion layer, and cathode channel - assumes non-Tafel kinetics to describe the complex kinetics of the multi-step methanol oxidation reaction at the anode, and accounts for the mixed potential associated with methanol crossover, induced both by diffusion and electro-osmotic drag. Polarization curves computed for various methanol feed concentrations, temperatures, and methanol feed velocities show good agreement with recent experimental results. The spatial distribution of methanol in the anode channels, together with the distributions of current density, methanol crossover and fuel utilization at the anode catalyst layer, are also presented for different opperating conditions.

  3. A single-phase model for liquid-feed DMFCs with non-Tafel kinetics

    Energy Technology Data Exchange (ETDEWEB)

    Vera, Marcos [Area de Mecanica de Fluidos, Universidad Carlos III de Madrid, Avda. de la Universidad 30, 28911 Leganes (Spain)

    2007-09-27

    An isothermal single-phase 3D/1D model for liquid-feed direct methanol fuel cells (DMFC) is presented. Three-dimensional (3D) mass, momentum and species transport in the anode channels and gas diffusion layer is modeled using a commercial, finite-volume based, computational fluid dynamics (CFD) software complemented with user supplied subroutines. The 3D model is locally coupled to a one-dimensional (1D) model accounting for the electrochemical reactions in both the anode and the cathode, which provides a physically sound boundary condition for the velocity and methanol concentration fields at the anode gas diffusion layer/catalyst interface. The 1D model - comprising the membrane-electrode assembly, cathode gas diffusion layer, and cathode channel - assumes non-Tafel kinetics to describe the complex kinetics of the multi-step methanol oxidation reaction at the anode, and accounts for the mixed potential associated with methanol crossover, induced both by diffusion and electro-osmotic drag. Polarization curves computed for various methanol feed concentrations, temperatures, and methanol feed velocities show good agreement with recent experimental results. The spatial distribution of methanol in the anode channels, together with the distributions of current density, methanol crossover and fuel utilization at the anode catalyst layer, are also presented for different opperating conditions. (author)

  4. Simulating of single phase flow in typical centrifugal pumps oil industry; Simulacao do escoamento monofasico em bombas centrifugas tipicas da industria do petroleo

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Ana Carla Costa; Silva, Aldrey Luis Morais da; Maitelli, Carla Wilza Souza de Paula [Universidade Federal do Rio Grande do Norte (UFRN), RN (Brazil)

    2012-07-01

    With the various techniques applied in production processes and oil exploration, has been using the artificial lift equipment with the aim of promoting an increase in flow in oil wells and gas. Choosing the most appropriate method of elevation depends on certain factors, among them the initial costs of installation, maintenance and conditions in the producing field, resulting in a more precise analysis of the project. Although there are other methods that represent a low cost and easy maintenance, the BCS method (Electrical Submersible Pumping), appears to be quite effective when it is intended to pump more flow of liquids from both terrestrial and marine environments, in conditions adverse temperature, presence of free gas in the mixture and viscous fluids. This method is based in most cases where the vessel pressure was low, and the fluid does not reach the surface without intervention of an artificial means which can lift them. Similar happens at the end of productive life of a resurgence for the well, or even when the flow of it is far below what is expected to produce, requiring a complement of natural energy through artificial lift. By definition, the BCS is a method of artificial lift in which a subsurface electric motor turns electrical energy into mechanical centrifugal pump and a multistage overlapping converts mechanical energy into kinetic energy of the engine bringing the fluid surface. In this study we performed computer simulations using a commercial program ANSYS #Registered Sign# CFX #Registered Sign# dimensions previously obtained by the 3D geometry in CAD format, with the objective of evaluating the single-phase flow inside typical centrifugal pump submerged in the oil industry. The variable measured was the height of elevation and drilling fluids are oil and water.(author)

  5. Low-Complexity Model Predictive Control of Single-Phase Three-Level Rectifiers with Unbalanced Load

    DEFF Research Database (Denmark)

    Ma, Junpeng; Song, Wensheng; Wang, Xiongfei

    2018-01-01

    The fluctuation of the neutral-point potential in single-phase three-level rectifiers leads to coupling between the line current regulation and dc-link voltage balancing, deteriorating the quality of line current. For addressing this issue, this paper proposes a low-complexity model predictive...

  6. Theoretical modelling and experimental investigation of single-phase and two-phase flow division at a tee-junction

    International Nuclear Information System (INIS)

    Lemonnier, H.; Hervieu, E.

    1991-01-01

    Phase separation in a tee-junction is modelled in the particular case of bubbly-flow. The model is based on a two-dimensional approach and hence, uses local equations. The first step consists in modelling the single-phase flow in the tee-junction. The free streamline theory is used to predict the flow of the continuous phase. The two recirculation zones which are presented in this case are predicted by the model. The second step consists in predicting the gas bubble paths as a result of the actions of the single-phase flow. Finally, the trajectories of gas bubbles are used to predict the separation characteristics of the tee-junction. Each step of the modelling procedure has been carefully tested by an in-depth experimental investigation. Excellent quantitative agreement is obtained between experimental results and model predictions. Moreover, the phase separation phenomenon is found to be clearly described by the model. (orig.)

  7. Analysis of free-surface flows through energy considerations: Single-phase versus two-phase modeling.

    Science.gov (United States)

    Marrone, Salvatore; Colagrossi, Andrea; Di Mascio, Andrea; Le Touzé, David

    2016-05-01

    The study of energetic free-surface flows is challenging because of the large range of interface scales involved due to multiple fragmentations and reconnections of the air-water interface with the formation of drops and bubbles. Because of their complexity the investigation of such phenomena through numerical simulation largely increased during recent years. Actually, in the last decades different numerical models have been developed to study these flows, especially in the context of particle methods. In the latter a single-phase approximation is usually adopted to reduce the computational costs and the model complexity. While it is well known that the role of air largely affects the local flow evolution, it is still not clear whether this single-phase approximation is able to predict global flow features like the evolution of the global mechanical energy dissipation. The present work is dedicated to this topic through the study of a selected problem simulated with both single-phase and two-phase models. It is shown that, interestingly, even though flow evolutions are different, energy evolutions can be similar when including or not the presence of air. This is remarkable since, in the problem considered, with the two-phase model about half of the energy is lost in the air phase while in the one-phase model the energy is mainly dissipated by cavity collapses.

  8. Impulse pumping modelling and simulation

    International Nuclear Information System (INIS)

    Pierre, B; Gudmundsson, J S

    2010-01-01

    Impulse pumping is a new pumping method based on propagation of pressure waves. Of particular interest is the application of impulse pumping to artificial lift situations, where fluid is transported from wellbore to wellhead using pressure waves generated at wellhead. The motor driven element of an impulse pumping apparatus is therefore located at wellhead and can be separated from the flowline. Thus operation and maintenance of an impulse pump are facilitated. The paper describes the different elements of an impulse pumping apparatus, reviews the physical principles and details the modelling of the novel pumping method. Results from numerical simulations of propagation of pressure waves in water-filled pipelines are then presented for illustrating impulse pumping physical principles, and validating the described modelling with experimental data.

  9. Modelling and Simulation of Single-Phase Series Active Compensator for Power Quality Improvement

    Science.gov (United States)

    Verma, Arun Kumar; Mathuria, Kirti; Singh, Bhim; Bhuvaneshwari, G.

    2017-10-01

    A single-phase active series compensator is proposed in this work to reduce harmonic currents at the ac mains and to regulate the dc link voltage of a diode bridge rectifier (DBR) that acts as the front end converter for a voltage source inverter feeding an ac motor. This ac motor drive is used in any of the domestic, commercial or industrial appliances. Under fluctuating ac mains voltages, the dc link voltage of the DBR depicts wide variations and hence the ac motor is used at reduced rating as compared to its name-plate rating. The active series compensator proposed here provides dual functions of improving the power quality at the ac mains and regulating the dc link voltage thus averting the need for derating of the ac motor.

  10. Myocardial CT perfusion imaging in a large animal model: comparison of dynamic versus single-phase acquisitions.

    Science.gov (United States)

    Schwarz, Florian; Hinkel, Rabea; Baloch, Elisabeth; Marcus, Roy P; Hildebrandt, Kristof; Sandner, Torleif A; Kupatt, Christian; Hoffmann, Verena; Wintersperger, Bernd J; Reiser, Maximilian F; Theisen, Daniel; Nikolaou, Konstantin; Bamberg, Fabian

    2013-12-01

    This study sought to compare dynamic versus single-phase high-pitch computed tomography (CT) acquisitions for the assessment of myocardial perfusion in a porcine model with adjustable degrees of coronary stenosis. The incremental value of the 2 different approaches to CT-based myocardial perfusion imaging remains unclear. Country pigs received stent implantation in the left anterior descending coronary artery, in which an adjustable narrowing (50% and 75% stenoses) was created using a balloon catheter. All animals underwent CT-based rest and adenosine-stress myocardial perfusion imaging using dynamic and single-phase high-pitch acquisitions at both degrees of stenosis. Fluorescent microspheres served as a reference standard for myocardial blood flow. Segmental CT-based myocardial blood flow (MBFCT) was derived from dynamic acquisitions. Segmental single-phase enhancement (SPE) was recorded from high-pitch, single-phase examinations. MBFCT and SPE were compared between post-stenotic and reference segments, and receiver-operating characteristic curve analysis was performed. Among 6 animals (28 ± 2 kg), there were significant differences of MBFCT and SPE between post-stenotic and reference segments for all acquisitions at 75% stenosis. By contrast, although for 50% stenosis at rest, MBFCT was lower in post-stenotic than in reference segments (0.65 ± 0.10 ml/g/min vs. 0.75 ± 0.16 ml/g/min, p < 0.05), there was no difference for SPE (128 ± 27 Hounsfield units vs. 137 ± 35 Hounsfield units, p = 0.17), which also did not significantly change under adenosine stress. In receiver-operating characteristic curve analyses, segmental MBFCT showed significantly better performance for ischemia prediction at 75% stenosis and stress (area under the curve: 0.99 vs. 0.89, p < 0.05) as well as for 50% stenosis, regardless of adenosine administration (area under the curve: 0.74 vs. 0.57 and 0.88 vs. 0.61, respectively, both p < 0.05). At higher degrees of coronary stenosis, both

  11. Harmonic Instability Analysis of Single-Phase Grid Connected Converter using Harmonic State Space (HSS) modeling method

    DEFF Research Database (Denmark)

    Kwon, Jun Bum; Wang, Xiongfei; Bak, Claus Leth

    2015-01-01

    The increasing number of renewable energy sources at the distribution grid is becoming a major issue for utility companies, since the grid connected converters are operating at different operating points due to the probabilistic characteristics of renewable energy. Besides, typically, the harmonics...... proposes a new model of a single phase grid connected renewable energy source using the Harmonic State Space modeling approach, which is able to identify such problems and the model can be extended to be applied in the multiple connected converter analysis. The modeling results show the different harmonic...... and impedance from other renewable energy sources are not taken carefully into account in the installation and design. However, this may bring an unknown harmonic instability into the multiple power sourced system and also make the analysis difficult due to the complexity of the grid network. This paper...

  12. Single-Phase PLLs

    DEFF Research Database (Denmark)

    Golestan, Saeed; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

    2017-01-01

    Single-phase phase-locked loops (PLLs) are popular for the synchronization and control of single-phase gridconnected converters. They are also widely used for monitoring and diagnostic purposes in the power and energy areas. In recent years, a large number of single-phase PLLs with different...... structures and properties have been proposed in the literature. The main aim of this paper is to provide a review of these PLLs. To this end, the single-phase PLLs are first classified into two major categories: 1) power-based PLLs (pPLLs), and 2) quadrature signal generation-based PLLs (QSG......-PLLs). The members of each category are then described and their pros and cons are discussed. This work provides a deep insight into characteristics of different single-phase PLLs and, therefore, can be considered as a reference for researchers and engineers....

  13. Numerical modelling of single-phase flow in rough fractures with contacts

    Science.gov (United States)

    Olkiewicz, Piotr; Dabrowski, Marcin

    2017-04-01

    Fracture flow may dominate in rocks with low porosity and it can accompany both industrial and natural processes. Typical examples of such processes are natural flows in crystalline rocks and industrial flows in oil and gas production systems or hydraulic fracturing. Fracture flow provides an important mechanism for transporting mass and energy. The distribution of the apertures of fracture and contact area are the key parameters with regard to the fracture transmissivity. We use the method of correlated random fields [Mourzenko, 1996] to generate synthetic fracture geometry in 3D. The flow of an incompressible Newtonian viscous fluid in geological formation can be approximated by the Stokes, the Stokes-Brinkman or the Reynolds models. We use our own implementation of the finite element method based on MILAMIN [Dabrowski, 2008] to solve governing partial differential equation over domain. We compare the Stokes, the Stokes-Brinkamn and the Reynolds models for fracture flow based on systematic numerical simulations for a wide range of geometric parameters. Mismatch between the Reynolds and the Stokes models becomes significant with increasing fracture roughness or contact area. The Stokes-Brinkman model is more accurate than Reynolds models due to additional Laplacian term, which allows to fulfil no-slip boundary condition. We present condition when the Reynolds and the Stokes-Brinkman models are valid. In the last three decades many authors used the Reynolds equation for studying fracture flow because of its simplicity. We recommend using the Stokes-Brinkman model for fracture flow, which allows to fulfil no-slip boundary condition on asperities boundary and is more accurate for rough fractures than the Reynolds model.

  14. Modeling Single-Phase PV HB-ZVR Inverter Connected to Grid

    DEFF Research Database (Denmark)

    Guo, Yougui; Zeng, Ping; Zhu, Jieqiong

    2011-01-01

    PLECS is used to model the PV H-bridge zero voltage rectifier (HB-ZVR) inverter connected to grid and good results are obtained. First, several common topologies of PV inverters are introduced. Then the unipolar PWM control strategy is described for PV HB-ZVR inverter. Third, PLECS is briefly...... introduced. Fourth, the modeling of PV HB-ZVR inverter is presented with PLECS. Finally, a series of simulations are carried out. The simulation results tell us PLECS is very powerful tool to real power circuits and it is very easy to simulate LCL filter. They have also verified that the unipolar PWM control...... strategy is feasible to control the PV HB-ZVR inverter....

  15. Modeling Single-Phase Inverter and Its Decentralized Coordinated Control by Using Feedback Linearization

    Directory of Open Access Journals (Sweden)

    Renke Han

    2014-01-01

    Full Text Available It is a very crucial problem to make a microgrid operated reasonably and stably. Considering the nonlinear mathematics model of inverter established in this paper, the input-output feedback linearization method is used to transform the nonlinear mathematics model of inverters to a linear tracking synchronization and consensus regulation control problem. Based on the linear mathematics model and multiagent consensus algorithm, a decentralized coordinated controller is proposed to make amplitudes and angles of voltages from inverters be consensus and active and reactive power shared in the desired ratio. The proposed control is totally distributed because each inverter only requires local and one neighbor’s information with sparse communication structure based on multiagent system. The hybrid consensus algorithm is used to keep the amplitude of the output voltages following the leader and the angles of output voltage as consensus. Then the microgrid can be operated more efficiently and the circulating current between DGs can be effectively suppressed. The effectiveness of the proposed method is proved through simulation results of a typical microgrid system.

  16. Single-phase and two-phase flow properties of mesaverde tight sandstone formation; random-network modeling approach

    Science.gov (United States)

    Bashtani, Farzad; Maini, Brij; Kantzas, Apostolos

    2016-08-01

    3D random networks are constructed in order to represent the tight Mesaverde formation which is located in north Wyoming, USA. The porous-space is represented by pore bodies of different shapes and sizes which are connected to each other by pore throats of varying length and diameter. Pore bodies are randomly distributed in space and their connectivity varies based on the connectivity number distribution which is used in order to generate the network. Network representations are then validated using publicly available mercury porosimetry experiments. The network modeling software solves the fundamental equations of two-phase immiscible flow incorporating wettability and contact angle variability. Quasi-static displacement is assumed. Single phase macroscopic properties (porosity, permeability) are calculated and whenever possible are compared to experimental data. Using this information drainage and imbibition capillary pressure, and relative permeability curves are predicted and (whenever possible) compared to experimental data. The calculated information is grouped and compared to available literature information on typical behavior of tight formations. Capillary pressure curve for primary drainage process is predicted and compared to experimental mercury porosimetry in order to validate the virtual porous media by history matching. Relative permeability curves are also calculated and presented.

  17. Modelling of flow with cavitation in centrifugal pump

    International Nuclear Information System (INIS)

    Homa, D; Wróblewski, W

    2014-01-01

    The paper concerns flow modelling in centrifugal pump with special consideration of cavitation phenomena. Cavitation occurs when local pressure drops below the saturation pressure according to the temperature of the flow. Vapour bubbles are created and then they flow through the areas with higher pressure. The bubbles collapse rapidly generating pressure wave, noise and vibration. Working under cavitation condition is very dangerous to a pump and can significantly shorten its lifetime. The investigated centrifugal pump consists of three two-flow rotors and stators working on a single shaft. The modelling process started with grid independence study. When the grid was chosen, the pump performance curve was obtained using the single phase fluid model. Next, using the results from pump performance curve calculations, the cavitation characteristic was obtained. The constant capacity was held when the pressure at the inlet was reduced. The two – phase model was used with Zwart cavitation model. The results indicate that the pump work in safe range of parameters. The analysis also provides wide range of information about the areas of vapour appearance. The most endangered regions are leading edges of rotor. When pressure at the inlet drops to about one third of pressure that calculations started from the cavitation cloud appears in whole rotor. The intense of vapour bubbles creation is greater near the shroud of the pump, rather than near the hub. As cavitation is strongly unsteady phenomena, the transient calculations were performed to check if the results are close to those obtained using the steady state type. The differences are not significant.

  18. Pump Component Model in SPACE Code

    International Nuclear Information System (INIS)

    Kim, Byoung Jae; Kim, Kyoung Doo

    2010-08-01

    This technical report describes the pump component model in SPACE code. A literature survey was made on pump models in existing system codes. The models embedded in SPACE code were examined to check the confliction with intellectual proprietary rights. Design specifications, computer coding implementation, and test results are included in this report

  19. Development of the self-learning machine for creating models of microprocessor of single-phase earth fault protection devices in networks with isolated neutral voltage above 1000 V

    Science.gov (United States)

    Utegulov, B. B.; Utegulov, A. B.; Meiramova, S.

    2018-02-01

    The paper proposes the development of a self-learning machine for creating models of microprocessor-based single-phase ground fault protection devices in networks with an isolated neutral voltage higher than 1000 V. Development of a self-learning machine for creating models of microprocessor-based single-phase earth fault protection devices in networks with an isolated neutral voltage higher than 1000 V. allows to effectively implement mathematical models of automatic change of protection settings. Single-phase earth fault protection devices.

  20. Mathematical model of the reactor coolant pump

    International Nuclear Information System (INIS)

    Kozuh, M.

    1989-01-01

    The mathematical model of reactor coolant pump is described in this paper. It is based on correlations for centrifugal reactor coolant pumps. This code is one of the elements needed for the simulation of the whole NPP primary system. In subroutine developed according to this model we tried in every possible detail to incorporate plant specific data for Krsko NPP. (author)

  1. An analytical model for prediction of two-phase (noncondensable) flow pump performance

    International Nuclear Information System (INIS)

    Furuya, O.

    1985-01-01

    During operational transients or a hypothetical LOCA (loss of coolant accident) condition, the recirculating coolant of PWR (pressurized water reactor) may flash into steam due to a loss of line pressure. Under such two-phase flow conditions, it is well known that the recirculation pump becomes unable to generate the same head as that of the single-phase flow case. Similar situations also exist in oil well submersible pumps where a fair amount of gas is contained in oil. Based on the one dimensional control volume method, an analytical method has been developed to determine the performance of pumps operating under two-phase flow conditions. The analytical method has incorporated pump geometry, void fraction, flow slippage and flow regime into the basic formula, but neglected the compressibility and condensation effects. During the course of model development, it has been found that the head degradation is mainly caused by higher acceleration on liquid phase and deceleration on gas phase than in the case of single-phase flows. The numerical results for head degradations and torques obtained with the model favorably compared with the air/water two-phase flow test data of Babcock and Wilcox (1/3 scale) and Creare (1/20 scale) pumps

  2. Switching model photovoltaic pumping system

    Science.gov (United States)

    Anis, Wagdy R.; Abdul-Sadek Nour, M.

    Photovoltaic (PV) pumping systems are widely used due to their simplicity, high reliability and low cost. A directly-coupled PV pumping system is the most reliable and least-cost PV system. The d.c. motor-pump group is not, however, working at its optimum operating point. A battery buffered PV pumping system introduces a battery between the PV array and the d.c. motor-pump group to ensure that the motor-pump group is operating at its optimum point. The size of the battery storage depends on system economics. If the battery is fully charged while solar radiation is available, the battery will discharge through the load while the PV array is disconnected. Hence, a power loss takes place. To overcome the above mentioned difficulty, a switched mode PV pumping is proposed. When solar radiation is available and the battery is fully charged, the battery is disconnected and the d.c. motor-pump group is directly coupled to the PV array. To avoid excessive operating voltage for the motor, a part of the PV array is switched off to reduce the voltage. As a result, the energy loss is significantly eliminated. Detailed analysis of the proposed system shows that the discharged water increases by about 10% when compared with a conventional battery-buffered system. The system transient performance just after the switching moment shows that the system returns to a steady state in short period. The variations in the system parameters lie within 1% of the rated values.

  3. Pumping Optimization Model for Pump and Treat Systems - 15091

    Energy Technology Data Exchange (ETDEWEB)

    Baker, S.; Ivarson, Kristine A.; Karanovic, M.; Miller, Charles W.; Tonkin, M.

    2015-01-15

    Pump and Treat systems are being utilized to remediate contaminated groundwater in the Hanford 100 Areas adjacent to the Columbia River in Eastern Washington. Design of the systems was supported by a three-dimensional (3D) fate and transport model. This model provided sophisticated simulation capabilities but requires many hours to calculate results for each simulation considered. Many simulations are required to optimize system performance, so a two-dimensional (2D) model was created to reduce run time. The 2D model was developed as a equivalent-property version of the 3D model that derives boundary conditions and aquifer properties from the 3D model. It produces predictions that are very close to the 3D model predictions, allowing it to be used for comparative remedy analyses. Any potential system modifications identified by using the 2D version are verified for use by running the 3D model to confirm performance. The 2D model was incorporated into a comprehensive analysis system (the Pumping Optimization Model, POM) to simplify analysis of multiple simulations. It allows rapid turnaround by utilizing a graphical user interface that: 1 allows operators to create hypothetical scenarios for system operation, 2 feeds the input to the 2D fate and transport model, and 3 displays the scenario results to evaluate performance improvement. All of the above is accomplished within the user interface. Complex analyses can be completed within a few hours and multiple simulations can be compared side-by-side. The POM utilizes standard office computing equipment and established groundwater modeling software.

  4. A simplified heat pump model for use in solar plus heat pump system simulation studies

    DEFF Research Database (Denmark)

    Perers, Bengt; Andersen, Elsa; Nordman, Roger

    2012-01-01

    Solar plus heat pump systems are often very complex in design, with sometimes special heat pump arrangements and control. Therefore detailed heat pump models can give very slow system simulations and still not so accurate results compared to real heat pump performance in a system. The idea here...

  5. Harmonic Instability Analysis of a Single-Phase Grid-Connected Converter Using a Harmonic State-Space Modeling Method

    DEFF Research Database (Denmark)

    Kwon, Jun Bum; Wang, Xiongfei; Blaabjerg, Frede

    2016-01-01

    The increasing number of renewable energy sources in the distribution grid is becoming a major issue for utility companies since grid-connected converters are operating at different operating points due to the probabilistic characteristics of the renewable energy. Usually, the harmonics and imped...... the harmonic coupling characteristic as well as different dynamic characteristics. The theoretical modeling and analysis are verified by simulations as well as experimental results.......The increasing number of renewable energy sources in the distribution grid is becoming a major issue for utility companies since grid-connected converters are operating at different operating points due to the probabilistic characteristics of the renewable energy. Usually, the harmonics...... and impedance from other renewable energy sources are not taken carefully into account in the installation and design of the systems. It can bring an unknown harmonic instability into a multiple power sourced system and makes the analysis difficult due to the complexity of the grid network. This paper proposes...

  6. Development of model pump for establishing hydraulic design of primary sodium pumps in PFBR

    International Nuclear Information System (INIS)

    Chougule, R.J.; Sahasrabudhe, H.G.; Rao, A.S.L.K.; Balchander, K.; Kale, R.D.

    1994-01-01

    Indira Gandhi Centre for Atomic Research, Kalpakkam indicated requirement of indigenous development of primary sodium pump, handling liquid sodium as coolant in Fast Breeder Reactor. The primary sodium pump concept selected in its preliminary design is a vertical, single stage, with single suction impeller, suction facing downwards. The pump is having diffuser, discharge casing and discharge collector. The 1/3 rd size model pump is developed to establish the hydraulic performance of the prototype primary sodium pump. The main objectives were to verify the hydraulic design to operate on low net positive suction head available (NPSHA), no evidence of visible cavitation at available NPSHA, the pump should be designed with a diffuser etc. The model pump PSP 250/40 was designed and successfully developed by Research and Development Division of M/s Kirloskar Brothers Ltd., Kirloskarvadi. The performance testing using model pump was successfully carried out on a closed circuit test rig. The performance of a model pump at three different speeds 1900 rpm, 1456 rpm and 975 rpm was established. The values of hydraulic axial thrust with and without balancing holes on impeller at 1900 rpm was measured. Visual cavitation study at 1900 rpm was carried out to establish the NPSH at bubble free operation of the pump. The tested performance of the model pump is converted to the full scale prototype pump. The predicted performance of prototype pump at 700 rpm was found to be meeting fully with the expected duties. (author). 6 figs., 3 tabs

  7. A simplified heat pump model for use in solar plus heat pump system simulation studies

    DEFF Research Database (Denmark)

    Perers, Bengt; Andersen, Elsa; Nordman, Roger

    2012-01-01

    Solar plus heat pump systems are often very complex in design, with sometimes special heat pump arrangements and control. Therefore detailed heat pump models can give very slow system simulations and still not so accurate results compared to real heat pump performance in a system. The idea here...... is to start from a standard measured performance map of test points for a heat pump according to EN 14825 and then determine characteristic parameters for a simplified correlation based model of the heat pump. By plotting heat pump test data in different ways including power input and output form and not only...... as COP, a simplified relation could be seen. By using the same methodology as in the EN 12975 QDT part in the collector test standard it could be shown that a very simple model could describe the heat pump test data very accurately, by identifying 4 parameters in the correlation equation found....

  8. A simplified heat pump model for use in solar plus heat pump system simulation studies

    DEFF Research Database (Denmark)

    Perers, Bengt; Andersen, Elsa; Nordman, Roger

    2012-01-01

    as COP, a simplified relation could be seen. By using the same methodology as in the EN 12975 QDT part in the collector test standard it could be shown that a very simple model could describe the heat pump test data very accurately, by identifying 4 parameters in the correlation equation found.......Solar plus heat pump systems are often very complex in design, with sometimes special heat pump arrangements and control. Therefore detailed heat pump models can give very slow system simulations and still not so accurate results compared to real heat pump performance in a system. The idea here...... is to start from a standard measured performance map of test points for a heat pump according to EN 14825 and then determine characteristic parameters for a simplified correlation based model of the heat pump. By plotting heat pump test data in different ways including power input and output form and not only...

  9. Fluid pumping: Some exploratory numerical models

    Science.gov (United States)

    Ord, A.; Henley, S.

    The concept of fluid pumping evolved from considerations of fluid behaviour within and surrounding faults and shear zones, particularly associated with earthquake initiation and propagation. Further, the interpretation of specific vein textures as originating from a crack-seal mechanism requires precipitation of material during pumping cycles. We explore here a new simple model for fluid pumping initiating within a dilatant, pressure dependant material, and the mechanical consequences of such a model, including the predicted behaviour of a fluid within the SiO2-H2O system. Changes in various properties such as permeability and mechanical properties are allowed according to rules based on defined geological processes. For example, porosity may increase with increasing shear and dilatancy of the rock, and both porosity and permeability decrease when and where the rock ‘seals’ as a result of pressure decrease and the resultant precipitation of SiO2. Histories of any variable may be explored for any part of the model. We may therefore test in a quantitative manner hypotheses for fluid pumping, and the deposition of quartz, and ultimately gold, in a deforming rock mass. Through exploring the feedback links between deformation, fluid flow, chemical transport, thermal transfer, we have the opportunity to test conceptually and quantitatively the various hypotheses for the formation of world class ore deposits.

  10. MPC of Single Phase Inverter for PV System

    OpenAIRE

    Irtaza M. Syed; Kaamran Raahemifar

    2014-01-01

    This paper presents a model predictive control (MPC) of a utility interactive (UI) single phase inverter (SPI) for a photovoltaic (PV) system at residential/distribution level. The proposed model uses single-phase phase locked loop (PLL) to synchronize SPI with the grid and performs MPC control in a dq reference frame. SPI model consists of boost converter (BC), maximum power point tracking (MPPT) control, and a full bridge (FB) voltage source inverter (VSI). No PI regula...

  11. Mathematical models for centrifugal pumps. Pt. 1

    Energy Technology Data Exchange (ETDEWEB)

    Hastrup, J.

    1984-01-01

    This report is primary concerned with mathematical models of the volute and impeller in centrifugal pumps. The pressure distribution in the volute is calculated. The results are compared to experimental results, and show a good qualitative agreement. Furthermore, the mass flow in the impeller is calculated, based on the pressure distribution in the volute. The mathematical model of the impeller is used to calculate the velocity and pressure distribution in the blade-to-blade plane of the impeller, including the effect of the shear stress in the boundary layers. Based on these calculations, the velocity distribution in the hub-to-shroud plane is calculated along a line in the middle of the blade-to-blade plane, giving all in all a quasi-three-dimensional description. The volute and impeller models are combined with simple mathematical models of the disc- friction and leakage losses, thereby giving the all-over efficiency of a centrifugal pump. The comparison with experimental results shows the need for a more accurate description of the entrance losses and disc-friction losses.

  12. Mathematical models for centrifugal pumps. Pt. 2

    Energy Technology Data Exchange (ETDEWEB)

    Hastrup, J.

    1984-01-01

    This report is primarily concerned with mathematical models of the volute and impeller in centrifugal pumps. The pressure distribution in the volute is calculated. The results are compared to experimental results, and show a good qualitative agreement. Furthermore, the mass flow in the impeller is calculated, based on the pressure distribution in the volute. The mathematical model of the impeller is used to calculate the velocity and pressure distribution in the blade-to-blade plane of the impeller, including the effect of the shear stress in the boundary layers. Based on these calculations, the velocity distribution in the hub-to-shroud plane is calculated along a line in the middle of the blade-to-blade plane, giving all in all a quasi-three-dimensional description. The volute and impeller models are combined with simple mathematical models of the disc-friction and leakage losses, thereby giving the all- over efficiency of a centrifugal pump. The comparison with experimental results shows the need for a more accurate description of the entrance losses and disc-friction losses.

  13. Mathematical models for centrifugal pumps. Pt. 3

    Energy Technology Data Exchange (ETDEWEB)

    Hastrup, J.

    1984-01-01

    This report is primary concerned with mathematical models of the volute and impeller in centrifugal pumps. The pressure distribution in the volute is calculated. The results are compared to experimental results, and show a good qualitative agreement. Furthermore, the mass flow in the impeller is calculated, based on the pressure distribution in the volute. The mathematical model of the impeller is used to calculate the velocity and pressure distribution in the blade-to-blade plane of the impeller, including the effect of the shear stress in the boundary layers. Based on these calculations, the velocity distribution in the hub-to-shroud plane is calculated along a line in the middle of the blade-to-blade plane, giving all in all a quasi-three-dimensional description. The volute and impeller models are combined with simple mathematical models of the disc-friction and leakage losses, thereby giving the all-over efficiency of a centrifugal pump. The comparison with experimental results shows the need for a more accurate description of the entrance losses and disc-friction losses.

  14. Lumped Parameters Model of a Crescent Pump

    Directory of Open Access Journals (Sweden)

    Massimo Rundo

    2016-10-01

    Full Text Available This paper presents the lumped parameters model of an internal gear crescent pump with relief valve, able to estimate the steady-state flow-pressure characteristic and the pressure ripple. The approach is based on the identification of three variable control volumes regardless of the number of gear teeth. The model has been implemented in the commercial environment LMS Amesim with the development of customized components. Specific attention has been paid to the leakage passageways, some of them affected by the deformation of the cover plate under the action of the delivery pressure. The paper reports the finite element method analysis of the cover for the evaluation of the deflection and the validation through a contactless displacement transducer. Another aspect described in this study is represented by the computational fluid dynamics analysis of the relief valve, whose results have been used for tuning the lumped parameters model. Finally, the validation of the entire model of the pump is presented in terms of steady-state flow rate and of pressure oscillations.

  15. Estimation of pump operational state with model-based methods

    International Nuclear Information System (INIS)

    Ahonen, Tero; Tamminen, Jussi; Ahola, Jero; Viholainen, Juha; Aranto, Niina; Kestilae, Juha

    2010-01-01

    Pumps are widely used in industry, and they account for 20% of the industrial electricity consumption. Since the speed variation is often the most energy-efficient method to control the head and flow rate of a centrifugal pump, frequency converters are used with induction motor-driven pumps. Although a frequency converter can estimate the operational state of an induction motor without external measurements, the state of a centrifugal pump or other load machine is not typically considered. The pump is, however, usually controlled on the basis of the required flow rate or output pressure. As the pump operational state can be estimated with a general model having adjustable parameters, external flow rate or pressure measurements are not necessary to determine the pump flow rate or output pressure. Hence, external measurements could be replaced with an adjustable model for the pump that uses estimates of the motor operational state. Besides control purposes, modelling the pump operation can provide useful information for energy auditing and optimization purposes. In this paper, two model-based methods for pump operation estimation are presented. Factors affecting the accuracy of the estimation methods are analyzed. The applicability of the methods is verified by laboratory measurements and tests in two pilot installations. Test results indicate that the estimation methods can be applied to the analysis and control of pump operation. The accuracy of the methods is sufficient for auditing purposes, and the methods can inform the user if the pump is driven inefficiently.

  16. Mathematical model of an optically pumped molecular laser

    CSIR Research Space (South Africa)

    Botha, LR

    2009-07-01

    Full Text Available A mathematical model was developed that accurately predicts the performance of an optically pumped HBr laser. Relatively high conversion efficiency was achieved. Tm pumped Ho:YLF is a viable source for pumping HBr laser, while HBr can be scaled...

  17. Modelling of Ammonia Heat Pump Desuperheaters

    DEFF Research Database (Denmark)

    Christensen, Stefan Wuust; Elmegaard, Brian; Markussen, Wiebke Brix

    2015-01-01

    This paper presents a study of modelling desuperheating in ammonia heat pumps. Focus is on the temperature profile of the superheated refrigerant. Typically, the surface area of a heat exchanger is estimated using the Log Mean Temperature Difference (LMTD) method. The assumption of this method...... is that the specific heat is constant throughout the temperature glide of the refrigerant in the heat exchanger. However, considering ammonia as refrigerant, the LMTD method does not give accurate results due to significant variations of the specific heat. By comparing the actual temperature profiles from a one...

  18. Mathematic models of photovoltaic motor-pump systems

    Energy Technology Data Exchange (ETDEWEB)

    Hamidat, A. [Centre for the Development of Renewable Energies, Cidex 01, BP.19, Bouzareah, Algiers (Algeria); Benyoucef, B. [Laboratory Des Materiaux and Energies Renouvelables, University of Tlemcen (Algeria)

    2008-05-15

    Photovoltaic (PV) pumping offers the possibility of supplying water to remote and desert regions for their daily needs. The sizing of the PV pumping systems is a very significant step in order to optimize the power peak of the PV array and to ensure the best choice of the motor, the pump and the inverter. Two mathematical models were proposed in this article to contribute in the studies of PV pumping sizing. These models link directly the operating electrical power to the water flow rate of the pump versus total head. These models are based essentially on the experimentation of pumps on CDER PV pumping test facility. Two pumping systems are tested: the first uses a centrifugal pump and the second uses a positive displacement pump. The results obtained by the models are very satisfactory. Also, the models enabled us to simulate the electrical and hydraulic performances of two tested pumps. The performances are calculated using the measured meteorological data of different sites located in Sahara and coastline regions of Algeria. (author)

  19. A model of annular linear induction pumps

    Energy Technology Data Exchange (ETDEWEB)

    Momozaki, Yoichi [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-10-27

    The present work explains how the magnetic field and the induced current are obtained when the distributed coils are powered by a 3 phase power supply.  From the magnetic field and the induced current, the thrust and the induction losses in the pump can be calculated to estimate the pump performance.

  20. Mathematical modelling of flow in disc friction LVAD pump

    Science.gov (United States)

    Medvedev, A. E.; Fomin, V. M.; Prikhodko, Yu. M.; Cherniavskiy, A. M.; Fomichev, V. P.; Fomichev, A. V.; Chekhov, V. P.; Ruzmatov, T. M.

    2017-10-01

    The need for blood circulation support systems in the treatment of chronic heart failure is constantly increasing as 20% of patients on the waiting list die every year. Despite the great need for mechanical heart support systems the use of available systems is limited by the high cost. Therefore, further research in the field of circulatory support systems is appropriate taking into account medical and technical requirements. One of the new research areas is viscous friction disk pumps for transporting liquids based on the Tesla pump principle. The experimental model of LVAD disk pump is developed. Analytical dependencies are obtained to optimize the hydraulic parameters of the pump. On their basis, the experimental model of LVAD disk pump was designed and created. The results of analytical and experimental studies of such a pump are presented.

  1. Advanced Power Electronic Interfaces for Distributed Energy Systems, Part 2: Modeling, Development, and Experimental Evaluation of Advanced Control Functions for Single-Phase Utility-Connected Inverter

    Energy Technology Data Exchange (ETDEWEB)

    Chakraborty, S.; Kroposki, B.; Kramer, W.

    2008-11-01

    Integrating renewable energy and distributed generations into the Smart Grid architecture requires power electronic (PE) for energy conversion. The key to reaching successful Smart Grid implementation is to develop interoperable, intelligent, and advanced PE technology that improves and accelerates the use of distributed energy resource systems. This report describes the simulation, design, and testing of a single-phase DC-to-AC inverter developed to operate in both islanded and utility-connected mode. It provides results on both the simulations and the experiments conducted, demonstrating the ability of the inverter to provide advanced control functions such as power flow and VAR/voltage regulation. This report also analyzes two different techniques used for digital signal processor (DSP) code generation. Initially, the DSP code was written in C programming language using Texas Instrument's Code Composer Studio. In a later stage of the research, the Simulink DSP toolbox was used to self-generate code for the DSP. The successful tests using Simulink self-generated DSP codes show promise for fast prototyping of PE controls.

  2. Thermodynamically Constrained Averaging Theory Approach for Modeling Flow and Transport Phenomena in Porous Medium Systems: 7. Single-Phase Megascale Flow Models.

    Science.gov (United States)

    Gray, William G; Miller, Cass T

    2009-08-01

    This work is the seventh in a series that introduces and employs the thermodynamically constrained averaging theory (TCAT) for modeling flow and transport in multiscale porous medium systems. This paper expands the previous analyses in the series by developing models at a scale where spatial variations within the system are not considered. Thus the time variation of variables averaged over the entire system is modeled in relation to fluxes at the boundary of the system. This implementation of TCAT makes use of conservation equations for mass, momentum, and energy as well as an entropy balance. Additionally, classical irreversible thermodynamics is assumed to hold at the microscale and is averaged to the megascale, or system scale. The fact that the local equilibrium assumption does not apply at the megascale points to the importance of obtaining closure relations that account for the large-scale manifestation of small-scale variations. Example applications built on this foundation are suggested to stimulate future work.

  3. Pulsatile fluidic pump demonstration and predictive model application

    International Nuclear Information System (INIS)

    Morgan, J.G.; Holland, W.D.

    1986-04-01

    Pulsatile fluidic pumps were developed as a remotely controlled method of transferring or mixing feed solutions. A test in the Integrated Equipment Test facility demonstrated the performance of a critically safe geometry pump suitable for use in a 0.1-ton/d heavy metal (HM) fuel reprocessing plant. A predictive model was developed to calculate output flows under a wide range of external system conditions. Predictive and experimental flow rates are compared for both submerged and unsubmerged fluidic pump cases

  4. PUMPS

    Science.gov (United States)

    Thornton, J.D.

    1959-03-24

    A pump is described for conveving liquids, particure it is not advisable he apparatus. The to be submerged in the liquid to be pumped, a conduit extending from the high-velocity nozzle of the injector,and means for applying a pulsating prcesure to the surface of the liquid in the conduit, whereby the surface oscillates between positions in the conduit. During the positive half- cycle of an applied pulse liquid is forced through the high velocity nozzle or jet of the injector and operates in the manner of the well known water injector and pumps liquid from the main intake to the outlet of the injector. During the negative half-cycle of the pulse liquid flows in reverse through the jet but no reverse pumping action takes place.

  5. S-102 Transfer Pump Restriction Modeling Results

    Energy Technology Data Exchange (ETDEWEB)

    Wells, Beric E.; Johnson, Kenneth I.; Rector, David R.; Trent, Donald S.

    2008-03-27

    It was determined that a radioactive waste leak in the Hanford S Farm in the vicinity of the S-102 retrieval pump discharge occurred because of over-pressurization and failure of the S-102 dilution water supply hose while operating the retrieval pump in reverse with an obstructed suction cavity and an unobstructed flow path to the dilution water supply hose. This report describes efforts to identify plausible scenarios for the waste leak to occur.

  6. Absorption Cycle Heat Pump Model for Control Design

    DEFF Research Database (Denmark)

    Vinther, Kasper; Just Nielsen, Rene; Nielsen, Kirsten Mølgaard

    2015-01-01

    Heat pumps have recently received increasing interest due to green energy initiatives and increasing energy prices. In this paper, a nonlinear dynamic model of a single-effect LiBr-water absorption cycle heat pump is derived for simulation and control design purposes. The model is based...... to operational data and different scenarios are simulated to investigate the operational stability of the heat pump. Finally, this paper provides suggestions and examples of derivation of lower order linear models for control design. © Copyright IEEE - All rights reserved....

  7. West Closure Complex Pump Intake Model, New Orleans, Louisiana

    Science.gov (United States)

    2013-02-01

    in Q/(d5 g)1/2 of 1.0. S/d = 1.3. No information on velocity uniformity at the pump impeller was available. 7. The Davis Pond pump station in New... Pond have successful operation at Q/(d5 g)1/2 of 1.35, 0.87, 1.0, and 1.3, respectively, but no velocity information at the pump impeller was...simulation, it was necessary to mini - mize head loss in the model discharge lines. The WCC model had long ERDC/CHL TR-13-1 23 Figure 17. Approach walls

  8. Pump

    International Nuclear Information System (INIS)

    Mole, C.J.

    1983-01-01

    An electromagnetic pump for circulating liquid -metal coolant through a nuclear reactor wherein opposite walls of a pump duct serve as electrodes to transmit current radially through the liquid-metal in the ducts. A circumferential electric field is supplied to the liquid-metal by a toroidal electromagnet which has core sections interposed between the ducts. The windings of the electromagnet are composed of metal which is superconductive at low temperatures and the electromagnet is maintained at a temperature at which it is superconductive by liquid helium which is fed through the conductors which supply the excitation for the electromagnet. The walls of the ducts joining the electrodes include metal plates insulated from the electrodes backed up by insulators so that they are capable of withstanding the pressure of the liquid-metal. These composite wall structures may also be of thin metal strips of low electrical conductivity backed up by sturdy insulators. (author)

  9. Modeling of diode pumped metastable rare gas lasers.

    Science.gov (United States)

    Yang, Zining; Yu, Guangqi; Wang, Hongyan; Lu, Qisheng; Xu, Xiaojun

    2015-06-01

    As a new kind of optically pumped gaseous lasers, diode pumped metastable rare gas lasers (OPRGLs) show potential in high power operation. In this paper, a multi-level rate equation based model of OPRGL is established. A qualitative agreement between simulation and Rawlins et al.'s experimental result shows the validity of the model. The key parameters' influences and energy distribution characteristics are theoretically studied, which is useful for the optimized design of high efficient OPRGLs.

  10. A thermoeconomic model of a photovoltaic heat pump

    OpenAIRE

    Mastrullo, R.; Renno, C.

    2008-01-01

    Abstract In this paper the model of a heat pump whose evaporator operates as a photovoltaic collector, is studied. The energy balance equations have been used for some heat pump components, and for each layer of the photovoltaic evaporator: covering glaze, photovoltaic modules, thermal absorber plate, refrigerant tube and insulator. The model has been solved by means of a program using proper simplifications. The system input is represented by the solar radiation intensity and the ...

  11. FILTER-NET STRUCTURE AND PUMPING ACTIVITY IN THE POLYCHAETE NEREIS-DIVERSICOLOR - EFFECTS OF TEMPERATURE AND PUMP-MODELING

    DEFF Research Database (Denmark)

    Riisgård, H.U.; Vedel, A.; Boye, H.

    1992-01-01

    on water processing were measured as clearance of suspended algal cells or measured directly. Pumping activity (undulating body movements of worms kept in glass tubes) was monitored using an infrared phototransducer technique. In the temperature interval from 5 to about 15-degrees-C there was a linear...... and a halving of the net cycle length. At low temperatures a tendency towards an extended pause between pumping periods was noticed. The N. diversicolor pump was modelled as a positive displacement leaking unit, and earlier data on back pressure characteristics were examined in light of the proposed model....... diversicolor muscular positive displacement pump (unlike for viscous ciliary pumps)....

  12. Preparation of single phase molybdenum boride

    International Nuclear Information System (INIS)

    Camurlu, Hasan Erdem

    2011-01-01

    Highlights: → Formation of Mo and a mixture of molybdenum boride phases take place in preparation of molybdenum borides. → It is intricate to prepare single phase molybdenum borides. → Formation of single phase MoB from MoO 3 + B 2 O 3 + Mg mixtures has not been reported previously. → Single phase MoB was successfully prepared through a combination of mechanochemical synthesis and annealing process. - Abstract: The formation of MoB through volume combustion synthesis (VCS), and through mechanochemical synthesis (MCS) followed by annealing has been investigated. MoO 3 , B 2 O 3 and Mg were used as reactants while MgO and NaCl were introduced as diluents. Products were leached in dilute HCl solution and were subjected to X-ray diffraction (XRD) analysis and scanning electron microscopy (SEM) examinations. Mo was the major phase component in the VCS products under all the experimental conditions. Mo 2 B, MoB, MoB 2 and Mo 2 B 5 were found as minor phases. Products of MCS contained a mixture of Mo 2 B, MoB, MoB 2 and Mo. After annealing the MCS product at 1400 deg. C for 3 h, single phase α-MoB was obtained.

  13. Single phase induction motor with starting performance

    Energy Technology Data Exchange (ETDEWEB)

    Popescu, M.; Demeter, E. [Research Institute for Electrical Machines, ICPE-ME, Bucharest (Romania); Navrapescu, V. [University `Politehnica` Bucharest, Electrical Engineering Faculty Splaiul Independentei, Bucharest (Romania)

    1997-12-31

    The paper presents problems related to a special type of single phase induction motor. The main novelty consists in the use of a conducting (aluminium casted) shell distributed on the periferic region of the rotor. As a result the starting performance, as well as the rated ones, is much improved in comparison with the conventional construction. (orig.) 4 refs.

  14. Flux Concentration and Pole Shaping in a Single Phase Hybrid Switched Reluctance Motor Drive

    DEFF Research Database (Denmark)

    Jakobsen, Uffe; Lu, Kaiyuan

    2010-01-01

    The single phase hybrid switched reluctance motor (HSRM) may be a good candidate for low-cost drives used for pump applications. This paper presents a new design of the HSRM with improved starting torque achieved by stator pole shaping, and a better arrangement of the embedded stator permanent...

  15. Effects of rolling on characteristics of single-phase water flow in narrow rectangular ducts

    International Nuclear Information System (INIS)

    Xing Dianchuan; Yan Changqi; Sun Licheng; Xu Chao

    2012-01-01

    Highlights: ► Mass flow rate and friction pressure drop with different pressure head are compared. ► The effect of pressure head on flow fluctuation is considered theoretically. ► Time-mean and real-time friction pressure drop in different rolling motion are studied. ► Rolling motion influences the fluctuation of friction pressure drop in two aspects. ► New correlation for frictional coefficient in rolling motion is achieved. - Abstract: Experimental and theoretical studies of rolling effects on characteristics of single-phase water flow in narrow rectangular ducts are performed under ambient temperature and pressure. Two types of pressure head are supplied by elevate water tank and pump respectively. The results show that the frictional pressure drop under rolling condition fluctuates periodically, with its amplitude decaying as mean Reynolds number increase and the rolling amplitude decrease, while the amplitude is nearly invariable with rolling period. Rolling motion influences the fluctuation amplitude of frictional pressure drop in two aspects, on the one hand, rolling reduced periodical pulsing flow leads to the fluctuation of the frictional pressure drop, on the other hand, additional force acting on fluid near the wall due to the rolling motion makes local frictional resistance oscillate periodically. The mass flow rate oscillates periodically in rolling motion with the pressure head supplied by water tank, while its fluctuation is so weak that could be neglected for the case of the pressure head supplied by pump. An empirical correlation for the frictional coefficient under rolling condition is achieved, and the experimental data is well correlated. A mathematical model is also developed to study the effect of pressure head on mass flow rate fluctuation in rolling motion. The fluctuation amplitude of the mass flow rate decreases rapidly with a higher pressure head. Comparing with the vertical condition, rolling motion nearly has no effects on

  16. Influence of clearance model on numerical simulation of centrifugal pump

    Science.gov (United States)

    Wang, Z.; Gao, B.; Yang, L.; Du, W. Q.

    2016-05-01

    Computing models are always simplified to save the computing resources and time. Particularly, the clearance that between impeller and pump casing is always ignored. But the completer model is, the more precise result of numerical simulation is in theory. This paper study the influence of clearance model on numerical simulation of centrifugal pump. We present such influence via comparing performance, flow characteristic and pressure pulsation of two cases that the one of two cases is the model pump with clearance and the other is not. And the results show that the head decreases and power increases so that efficiency decreases after computing with front and back cavities. Then no-leakage model would improve absolute velocity magnitude in order to reach the rated flow rate. Finally, more disturbance induced by front cavity flow and wear-ring flow would change the pressure pulsation of impeller and volute. The performance of clearance flow is important for the whole pump in performance, flow characteristic, pressure pulsation and other respects.

  17. Numerical simulation of interior flow field of nuclear model pump

    International Nuclear Information System (INIS)

    Wang Chunlin; Peng Na; Kang Can; Zhao Baitong; Zhang Hao

    2009-01-01

    Reynolds time-averaged N-S equations and the standard k-ε turbulent model were adopted, and three-dimensional non-structural of tetrahedral mesh division was used for modeling. Multiple reference frame model of rotating fluid mechanical model was used, under the design condition, the three-dimensional incompressible turbulent flow of nuclear model pump was simulated, and the results preferably post the characteristics of the interior flow field. This paper first analyzes the total pressure and velocity distribution in the flow field, and then describes the interior flow field characteristics of each part such as the impeller, diffuser and spherical shell, and also discusses the reasons that cause these characteristics. The study results can be used to estimate the performance of nuclear model pump, and will provide some useful references for its hydraulic optimized design. (authors)

  18. Model Based Fault Detection in a Centrifugal Pump Application

    DEFF Research Database (Denmark)

    Kallesøe, Carsten; Cocquempot, Vincent; Izadi-Zamanabadi, Roozbeh

    2006-01-01

    A model based approach for fault detection in a centrifugal pump, driven by an induction motor, is proposed in this paper. The fault detection algorithm is derived using a combination of structural analysis, observer design and Analytical Redundancy Relation (ARR) design. Structural considerations...

  19. A Physically Based Model for Air-Lift Pumping

    Science.gov (United States)

    FrançOis, Odile; Gilmore, Tyler; Pinto, Michael J.; Gorelick, Steven M.

    1996-08-01

    A predictive, physically based model for pumping water from a well using air injection (air-lift pumping) was developed for the range of flow rates that we explored in a series of laboratory experiments. The goal was to determine the air flow rate required to pump a specific flow rate of water in a given well, designed for in-well air stripping of volatile organic compounds from an aquifer. The model was validated against original laboratory data as well as data from the literature. A laboratory air-lift system was constructed that consisted of a 70-foot-long (21-m-long) pipe, 5.5 inches (14 cm) inside diameter, in which an air line of 1.3 inches (3.3 cm) outside diameter was placed with its bottom at different elevations above the base of the long pipe. Experiments were conducted for different levels of submergence, with water-pumping rates ranging from 5 to 70 gallons/min (0.32-4.4 L/s), and air flow ranging from 7 to 38 standard cubic feet/min (0.2-1.1 m3 STP/min). The theoretical approach adopted in the model was based on an analysis of the system as a one-dimensional two-phase flow problem. The expression for the pressure gradient includes inertial energy terms, friction, and gas expansion versus elevation. Data analysis revealed that application of the usual drift-flux model to estimate the air void fraction is not adequate for the observed flow patterns: either slug or churn flow. We propose a modified drift-flux model that accurately predicts air-lift pumping requirements for a range of conditions representative of in-well air-stripping operations.

  20. Model of the direct solar-pumped iodine photodissociation laser

    Science.gov (United States)

    Alexandrov, Boris S.; Fokanov, V. P.; Kudryavtsev, S. N.; Pavlov, A. B.

    1996-04-01

    The results of the experimental and theoretical DSPIL modeling are presented. The parameters of the generation pulse (energy, duration, delay time) are measured for the series of perfluoriodide laser compounds under pumping conditions imitating the space solar radiation spectrum. The time dependence of the radiation spectrum was measured for the pumping pulse. The spectrum of this pulse corresponds to the ABB spectrum with temperature 6000 K in the pulse beginning and 3500 K in the end. The generation energy ratio (E10/E1) in repeatedly pumping pulse action without the active laser medium change was measured in this experiment. The empirical linear dependence between quantities 1n(E10/E1) and 1n(k3/k4) is received, where E1 and E10 are the energies of generation pulse after first and tenth pumping pulses. The mathematical model of DSPIL, containing the main kinetical processes description, is developed. The computing evaluation of the energy characteristics of DSPIL are presented.

  1. Is flexoelectricity the coupling factor between chemical energy and osmotic work in the pump? A model of pump.

    Science.gov (United States)

    Petrov, A G; Mircevová, L

    1986-08-01

    The following pump model is proposed. A gate is responsible for pump specificity. The actual driving force of the transport of ions against the electrochemical potential gradient is the electric field originating from an altered curvature of the phospholipid bilayer around the pump. The physical origin of this curvature-induced electric field arises from a basic liquid crystal property of lipid bilayers called flexoelectricity. Alterations occurring in phospholipid bilayer arrangement are due to changed conformation of protein; the main energy source of this change is ATP. Consequently, the energy of ATP is transformed, in our pump model, into osmotic work in following steps: ATP + protein (conformation I)----protein (conformation II)----alterations in phospholipid bilayer arrangement----electric field----active transport of ions. This model is the most simple one. In Na, K-pump there is a bidirectional ion transport. In our model of Na, K-pump three conformational states of pump proteins and two different electric fields formed sequentially in opposite directions are supposed.

  2. Modeling Results For the ITER Cryogenic Fore Pump. Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Pfotenhauer, John M. [University of Wisconsin, Madison, WI (United States); Zhang, Dongsheng [University of Wisconsin, Madison, WI (United States)

    2014-03-31

    A numerical model characterizing the operation of a cryogenic fore-pump (CFP) for ITER has been developed at the University of Wisconsin – Madison during the period from March 15, 2011 through June 30, 2014. The purpose of the ITER-CFP is to separate hydrogen isotopes from helium gas, both making up the exhaust components from the ITER reactor. The model explicitly determines the amount of hydrogen that is captured by the supercritical-helium-cooled pump as a function of the inlet temperature of the supercritical helium, its flow rate, and the inlet conditions of the hydrogen gas flow. Furthermore the model computes the location and amount of hydrogen captured in the pump as a function of time. Throughout the model’s development, and as a calibration check for its results, it has been extensively compared with the measurements of a CFP prototype tested at Oak Ridge National Lab. The results of the model demonstrate that the quantity of captured hydrogen is very sensitive to the inlet temperature of the helium coolant on the outside of the cryopump. Furthermore, the model can be utilized to refine those tests, and suggests methods that could be incorporated in the testing to enhance the usefulness of the measured data.

  3. Dynamic characteristics and mechatronics model for maglev blood pump

    Science.gov (United States)

    Sun, Kun; Chen, Chen

    2017-01-01

    Magnetic bearing system(MBs) has been developed in the new-generation blood pump due to its low power consumption, low blood trauma and high durability. However, MBs for a blood pump were almost influenced by a series of factors such as hemodynamics, rotation speeds and actuator response in working fluids, compared with those applied in other industrial fields. In this study, the dynamic characteristics of MBs in fluid environments, including the influence of the pumping fluid and rotation of the impeller on the radial dynamic model were investigated by measuring the frequency response to sinusoidal excitation upon coils, and the response of radial displacement during a raise in the speed. The excitation tests were conducted under conditions in which the blood pump was levitated in air and water and with or without rotation. The experimental and simulated results indicate that rotations of the impeller affected the characteristics of MBs in water apparently, and the vibration in water was decreased, compared with that in air due to the hydraulic force. During the start-up and rotation, the actuator failed to operate fully and timely, and the voltage supplied can be chosen under the consideration of the rotor displacement and consumption.

  4. Model-based sensor-augmented pump therapy.

    Science.gov (United States)

    Grosman, Benyamin; Voskanyan, Gayane; Loutseiko, Mikhail; Roy, Anirban; Mehta, Aloke; Kurtz, Natalie; Parikh, Neha; Kaufman, Francine R; Mastrototaro, John J; Keenan, Barry

    2013-03-01

    In insulin pump therapy, optimization of bolus and basal insulin dose settings is a challenge. We introduce a new algorithm that provides individualized basal rates and new carbohydrate ratio and correction factor recommendations. The algorithm utilizes a mathematical model of blood glucose (BG) as a function of carbohydrate intake and delivered insulin, which includes individualized parameters derived from sensor BG and insulin delivery data downloaded from a patient's pump. A mathematical model of BG as a function of carbohydrate intake and delivered insulin was developed. The model includes fixed parameters and several individualized parameters derived from the subject's BG measurements and pump data. Performance of the new algorithm was assessed using n = 4 diabetic canine experiments over a 32 h duration. In addition, 10 in silico adults from the University of Virginia/Padova type 1 diabetes mellitus metabolic simulator were tested. The percentage of time in glucose range 80-180 mg/dl was 86%, 85%, 61%, and 30% using model-based therapy and [78%, 100%] (brackets denote multiple experiments conducted under the same therapy and animal model), [75%, 67%], 47%, and 86% for the control experiments for dogs 1 to 4, respectively. The BG measurements obtained in the simulation using our individualized algorithm were in 61-231 mg/dl min-max envelope, whereas use of the simulator's default treatment resulted in BG measurements 90-210 mg/dl min-max envelope. The study results demonstrate the potential of this method, which could serve as a platform for improving, facilitating, and standardizing insulin pump therapy based on a single download of data. © 2013 Diabetes Technology Society.

  5. Numerical modelling of the pump-to-signal relative intensity noise ...

    Indian Academy of Sciences (India)

    2015-11-27

    Nov 27, 2015 ... An accurate numerical model to investigate the pump-to-signal relative intensity noise (RIN) transfer in two-pump fibre optical parametric amplifiers (2-P FOPAs) for low modulation frequencies is presented. Compared to other models in the field, this model takes into account the fibre loss, pump depletion as ...

  6. Instability of single-phase natural circulation

    International Nuclear Information System (INIS)

    Xie Heng; Zhang Jinling; Jia Dounan

    1997-01-01

    The author has investigated the instability of single-phase flows in natural circulation loops. The momentum equation and energy equation are made dimensionless according to some definitions, and some important dimensionless parameters are gotten. The authors decomposed the mean mass flowrate and temperature into a steady solution and a small disturbance equations. Through solving the disturbance equations, the authors get the neutral stability curves. The authors have studied the effect of the two parameters which represent the ratio of buoyancy force to the friction loss in the loop on the stability of loops. The authors also have studied the effect of the difference of height between the center of heat source and the heat sink on the stability

  7. Numerical modelling of the pump-to-signal relative intensity noise ...

    Indian Academy of Sciences (India)

    , pump depletion as ... is considered as detrimental in communication systems as it deteriorates the signal wave and affects the device ... In this paper, a comprehensive numerical model for investigating the pump-to-signal. RIN transfer in 2-P ...

  8. Synthesis and magnetic properties of single phase titanomagnetites

    Energy Technology Data Exchange (ETDEWEB)

    Schoenthal, W., E-mail: wms@andrew.cmu.edu; Liu, X.; Cox, T.; Laughlin, D. E.; McHenry, M. E. [Materials Science and Engineering, Carnegie Mellon University, Pittsburgh, Pennsylvania 15213 (United States); Mesa, J. L.; Diaz-Michelena, M. [Instituto Nacional de Tecnica Aeroespacial, Madrid (Spain); Maicas, M. [Universidad Politecnica de Madrid, ISOM-ETSIT, Madrid (Spain)

    2014-05-07

    The focus of this paper is the study of cation distributions and resulting magnetizations in titanomagnetites (TMs), (1−x)Fe{sub 3}O{sub 4−x}Fe{sub 2}TiO{sub 4} solid solutions. TM remnant states are hypothesized to contribute to planetary magnetic field anomalies. This work correlates experimental data with proposed models for the TM pseudobinary. Improved synthesis procedures are reported for single phase Ulvöspinel (Fe{sub 2}TiO{sub 4}), and TM solid solutions were made using solid state synthesis techniques. X-ray diffraction and scanning electron microscopy show samples to be single phase solid solutions. M-H curves of TM75, 80, 85, 90, and 95 (TMX where X = at. % of ulvöspinel) were measured using a Physical Property Measurement System at 10 K, in fields of 0 to 8 T. The saturation magnetization was found to be close to that predicted by the Neel model for cation distribution in TMs. M-T curves of the remnant magnetization were measured from 10 K to 350 K. The remnant magnetization was acquired at 10 K by applying an 8 T field and then releasing the field. Experimental Neel temperatures are reported for samples in the Neel model ground state.

  9. Impeller-pump model derived from conservation laws applied to the simulation of the cardiovascular system coupled to heart-assist pumps.

    Science.gov (United States)

    Shi, Yubing; Korakianitis, Theodosios

    2018-02-01

    Previous numerical models of impeller pumps for ventricular assist devices utilize curve-fitted polynomials to simulate experimentally-obtained pressure difference versus flow rate characteristics of the pumps, with pump rotational speed as a parameter. In this paper the numerical model for the pump pressure difference versus flow rate characteristics is obtained by analytic derivation. The mass, energy and angular momentum conservation laws are applied to the working fluid passing through the impeller geometry and coupled with the turbomachine's velocity diagram. This results in the construction of a pressure difference versus flow rate characteristic for the specific pump geometry, with pump rotational speed as parameter. Overall this model allows modifications of the pump geometry, so that the pump avoids undesirable operating conditions, such as regurgitant flow. The HeartMate III centrifugal pump is used as an example to demonstrate the application of the technique. The parameterised numerical model for HeartMate III derived by this technique is coupled with a numerical model for the human cardiovascular system, and the combination is used to investigate the cardiovascular response under different conditions of impeller pump support. Conditions resulting in regurgitant pump flow, the pump resulting in aortic valve closure and taking over completely the pumping action from the diseased heart, and inner ventricular wall suction at pump inlet are predicted by the model. The simulation results suggest that for normal HeartMate III operation the pump speed should be maintained between 3,100 and 4,500 rpm to avoid regurgitant pump flow and ventricular suction. To obtain optimal overall cardiovascular system plus pump response, the pump operating speed should be 3,800 rpm. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Comparison of numerical results with experimental data for single-phase natural convection in an experimental sodium loop

    International Nuclear Information System (INIS)

    Ribando, R.J.

    1979-01-01

    A comparison is made between computed results and experimental data for a single-phase natural convection test in an experimental sodium loop. The test was conducted in the Thermal-Hydraulic Out-of-Reactor Safety (THORS) facility, an engineering-scale high temperature sodium loop at the Oak Ridge National Laboratory (ORNL) used for thermal-hydraulic testing of simulated Liquid Metal Fast Breeder Reactor (LMFBR) subassemblies at normal and off-normal operating conditions. Heat generation in the 19 pin assembly during the test was typical of decay heat levels. The test chosen for analysis in this paper was one of seven natural convection runs conducted in the facility using a variety of initial conditions and testing parameters. Specifically, in this test the bypass line was open to simulate a parallel heated assembly and the test was begun with a pump coastdown from a small initial forced flow. The computer program used to analyze the test, LONAC (LOw flow and NAtural Convection) is an ORNL-developed, fast-running, one-dimensional, single-phase, finite-difference model used for simulating forced and free convection transients in the THORS loop

  11. Comparison of numerical results with experimental data for single-phase natural convection in an experimental sodium loop. [LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Ribando, R.J.

    1979-01-01

    A comparison is made between computed results and experimental data for a single-phase natural convection test in an experimental sodium loop. The test was conducted in the Thermal-Hydraulic Out-of-Reactor Safety (THORS) facility, an engineering-scale high temperature sodium loop at the Oak Ridge National Laboratory (ORNL) used for thermal-hydraulic testing of simulated Liquid Metal Fast Breeder Reactor (LMFBR) subassemblies at normal and off-normal operating conditions. Heat generation in the 19 pin assembly during the test was typical of decay heat levels. The test chosen for analysis in this paper was one of seven natural convection runs conducted in the facility using a variety of initial conditions and testing parameters. Specifically, in this test the bypass line was open to simulate a parallel heated assembly and the test was begun with a pump coastdown from a small initial forced flow. The computer program used to analyze the test, LONAC (LOw flow and NAtural Convection) is an ORNL-developed, fast-running, one-dimensional, single-phase, finite-difference model used for simulating forced and free convection transients in the THORS loop.

  12. One-phase and two-phase homologous curves for coolant pumps of the pressurized light water nuclear reactors

    International Nuclear Information System (INIS)

    Santos, G.A. dos.

    1990-01-01

    The two-phase coolant pump model of pressurized light water nuclear reactors is an important point for the loss of primary coolant accident analysis. The single-phase pump characteristics are an essential feature for operational transients studies, for example, the shut-down and start-up of pump. These parameters, in terms of the homologous curves, set up the complete performance of the pump and are input for transients and accidents analysis thermal-hydraulic codes. This work propose a mathematical model able to predict the single-phase and two-phase homologous curves where it was incorporated geometric and operational pump condition. The results were compared with the experimental tests data from literature and it has showed a good agreement. (author)

  13. Critical cavitation coefficient analysis of a space low specific centrifugal pump with micro gravity

    Science.gov (United States)

    Liu, J. T.; Li, Y.; Gao, Y.; Hu, Q.; Zhou, C.; Wu, Y. L.

    2016-05-01

    Centrifugal pump was used in the loop as a baselined unit. The flow rate of the pump was very small, while the head was high. This space pump must work stable for a long time (more than a year), so the performance of the pump attracted public attention. The rotational speed of the impeller was limited for stability, so the pump belonged to low specific centrifugal pump. In this paper, a single-phase centrifugal pump, which was designed for single-phase fluid loops in satellites, was modeled for numerical simulation. The hydraulic region of the pump was discretized by structured mesh. Three dimensional (3-D) flow in the pump was studied by the use of computational fluid dynamics. Partially-Averaged Navier- Stokes (PANS) model based on RNG k-ε turbulence model was developed for the simulation of the unsteady flow. Velocity inlet and pressure outlet was used as the boundary conditions. Interface was used between the impeller and the casing, as well as the impeller and inlet pipe. Performances and pressure fluctuation of the pump were investigated. The dominant frequency of the pressure fluctuation is blade passing frequency at the region close to the tongue of the casing, while it is twice of blade passing frequency at the other region.

  14. PUMP: analog-hybrid reactor coolant hydraulic transient model

    International Nuclear Information System (INIS)

    Grandia, M.R.

    1976-03-01

    The PUMP hybrid computer code simulates flow and pressure distribution; it is used to determine real time response to starting and tripping all combinations of PWR reactor coolant pumps in a closed, pressurized, four-pump, two-loop primary system. The simulation includes the description of flow, pressure, speed, and torque relationships derived through pump affinity laws and from vendor-supplied pump zone maps to describe pump dynamic characteristics. The program affords great flexibility in the type of transients that can be simulated

  15. Benchmarks for single-phase flow in fractured porous media

    Science.gov (United States)

    Flemisch, Bernd; Berre, Inga; Boon, Wietse; Fumagalli, Alessio; Schwenck, Nicolas; Scotti, Anna; Stefansson, Ivar; Tatomir, Alexandru

    2018-01-01

    This paper presents several test cases intended to be benchmarks for numerical schemes for single-phase fluid flow in fractured porous media. A number of solution strategies are compared, including a vertex and two cell-centred finite volume methods, a non-conforming embedded discrete fracture model, a primal and a dual extended finite element formulation, and a mortar discrete fracture model. The proposed benchmarks test the schemes by increasing the difficulties in terms of network geometry, e.g. intersecting fractures, and physical parameters, e.g. low and high fracture-matrix permeability ratio as well as heterogeneous fracture permeabilities. For each problem, the results presented are the number of unknowns, the approximation errors in the porous matrix and in the fractures with respect to a reference solution, and the sparsity and condition number of the discretized linear system. All data and meshes used in this study are publicly available for further comparisons.

  16. Modeling of a Membrane-Based Absorption Heat Pump

    Energy Technology Data Exchange (ETDEWEB)

    Woods, J.; Pellegrino, J.; Kozubal, E.; Slayzak, S.; Burch, J.

    2009-01-01

    In this paper, a membrane heat pump is proposed and analyzed. Fundamentally, the proposed heat pump consists of an aqueous CaCl{sub 2} solution flow separated from a water flow by a vapor-permeable membrane. The low activity of the solution results in a net flux of water vapor across the membrane, which heats the solution stream and cools the water stream. This mechanism upgrades water-side low-temperature heat to solution-side high-temperature heat, creating a 'temperature lift.' The modeling results show that using two membranes and an air gap instead of a single membrane increases the temperature lift by 185%. The model predicts temperature lifts for the air-gap design of 24, 16, and 6 C for inlet temperatures of 55, 35, and 15 C, respectively. Membranes with lower thermal conductivities and higher porosities improve the performance of single-membrane designs while thinner membranes improve the performance of air-gap designs. This device can be used with a solar heating system which already uses concentrated salt solutions for liquid-desiccant cooling.

  17. SINGLE-PHASE AND TWO-PHASE SECONDARY COOLANTS: SIMULATION AND EVALUATION OF THEIR THERMOPHYSICAL PROPERTIES

    Directory of Open Access Journals (Sweden)

    Pedro Samuel Gomes Medeiros

    2011-09-01

    Full Text Available This paper makes a comparative analysis of the thermophysical properties of ice slurry with conventional single-phase secondary fluids used in thermal storage cooling systems. The ice slurry is a two-phase fluid consisting of water, antifreeze and ice crystals. It is a new technology that has shown great energy potential. In addition to transporting energy as a heat transfer fluid, it has thermal storage properties due to the presence of ice, storing coolness by latent heat of fusion. The single-phase fluids analyzed are water-NaCl and water-propylene glycol solutions, which also operate as carrier fluids in ice slurry. The presence of ice changes the thermophysical properties of aqueous solutions and a number of these properties were determined: density, thermal conductivity and dynamic viscosity. Data were obtained by software simulation. The results show that the presence of 10% by weight of ice provides a significant increase in thermal conductivity and dynamic viscosity, without causing changes in density. The rheological behavior of ice slurries, associated with its high viscosity, requires higher pumping power; however, this was not significant because higher thermal conductivity allows a lower mass flow rate without the use of larger pumps. Thus, the ice slurry ensures its high potential as a secondary fluid in thermal storage cooling systems, proving to be more efficient than single-phase secondary fluids.

  18. Single-phase power distribution system power flow and fault analysis

    Science.gov (United States)

    Halpin, S. M.; Grigsby, L. L.

    1992-01-01

    Alternative methods for power flow and fault analysis of single-phase distribution systems are presented. The algorithms for both power flow and fault analysis utilize a generalized approach to network modeling. The generalized admittance matrix, formed using elements of linear graph theory, is an accurate network model for all possible single-phase network configurations. Unlike the standard nodal admittance matrix formulation algorithms, the generalized approach uses generalized component models for the transmission line and transformer. The standard assumption of a common node voltage reference point is not required to construct the generalized admittance matrix. Therefore, truly accurate simulation results can be obtained for networks that cannot be modeled using traditional techniques.

  19. Numerical modelling of the pump-to-signal relative intensity noise ...

    Indian Academy of Sciences (India)

    An accurate numerical model to investigate the pump-to-signal relative intensity noise (RIN) transfer in two-pump fibre optical parametric amplifiers (2-P FOPAs) for low modulation frequencies is presented. Compared to other models in the field, this model takes into account the fibre loss, pump depletion as well as the gain ...

  20. An investigational study of minimum rotational pump speed to avoid retrograde flow in three centrifugal blood pumps in a pediatric extracorporeal life support model.

    Science.gov (United States)

    Clark, Joseph B; Guan, Yulong; McCoach, Robert; Kunselman, Allen R; Myers, John L; Undar, Akif

    2011-05-01

    During extracorporeal life support with centrifugal blood pumps, retrograde pump flow may occur when the pump revolutions decrease below a critical value determined by the circuit resistance and the characteristics of the pump. We created a laboratory model to evaluate the occurrence of retrograde flow in each of three centrifugal blood pumps: the Rotaflow, the CentriMag, and the Bio-Medicus BP-50. At simulated patient pressures of 60, 80, and 100 mmHg, each pump was evaluated at speeds from 1000 to 2200 rpm and flow rates were measured. Retrograde flow occurred at low revolution speeds in all three centrifugal pumps. The Bio-Medicus pump was the least likely to demonstrate retrograde flow at low speeds, followed by the Rotaflow pump. The CentriMag pump showed the earliest transition to retrograde flow, as well as the highest degree of retrograde flow. At every pump speed evaluated, the Bio-Medicus pump delivered the highest antegrade flow and the CentriMag pump delivered the least.

  1. Multiphysics Modeling of an Annular Linear Induction Pump With Applications to Space Nuclear Power Systems

    Science.gov (United States)

    Kilbane, J.; Polzin, K. A.

    2014-01-01

    An annular linear induction pump (ALIP) that could be used for circulating liquid-metal coolant in a fission surface power reactor system is modeled in the present work using the computational COMSOL Multiphysics package. The pump is modeled using a two-dimensional, axisymmetric geometry and solved under conditions similar to those used during experimental pump testing. Real, nonlinear, temperature-dependent material properties can be incorporated into the model for both the electrically-conducting working fluid in the pump (NaK-78) and structural components of the pump. The intricate three-phase coil configuration of the pump is implemented in the model to produce an axially-traveling magnetic wave that is qualitatively similar to the measured magnetic wave. The model qualitatively captures the expected feature of a peak in efficiency as a function of flow rate.

  2. Single-Phase Hybrid Switched Reluctance Motor for Low-Power Low-Cost Applications

    DEFF Research Database (Denmark)

    Lu, Kaiyuan; Rasmussen, Peter Omand; Jakobsen, Uffe

    2011-01-01

    This paper presents a new single-phase, Hybrid Switched Reluctance (HSR) motor for low-cost, low-power, pump or fan drive systems. Its single-phase configuration allows use of a simple converter to reduce the system cost. Cheap ferrite magnets are used and arranged in a special flux concentration...... manner to increase effectively the torque density and efficiency of this machine. The efficiency of this machine is comparable to the efficiency of a traditional permanent magnet machine in the similar power range. The cogging torque, due to the existence of the permanent magnetic field, is beneficially...... used to reduce the torque ripple and enable self-starting of the machine. The starting torque of this machine is significantly improved by a slight extension of the stator pole-arc. A prototype machine and a complete drive system has been manufactured and tested. Results are given in this paper....

  3. Development of a single-phase thermosiphon for cold collection and storage of radiative cooling

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Dongliang; Martini, Christine Elizabeth; Jiang, Siyu; Ma, Yaoguang; Zhai, Yao; Tan, Gang; Yin, Xiaobo; Yang, Ronggui

    2017-11-01

    A single-phase thermosiphon is developed for cold collection and storage of radiative cooling. Compared to the conventional nocturnal radiative cooling systems that use an electric pump to drive the heat transfer fluid, the proposed single-phase thermosiphon uses the buoyancy force to drive heat transfer fluid. This solution does not require electricity, therefore improving the net gain of the radiative cooling system. A single-phase thermosiphon was built, which consists of a flat panel, a cold collection tank, a water return tube, and a water distribution tank. Considering that outdoor radiative cooling flux is constantly changing (i.e. uncontrollable), an indoor testing facility was developed to provide a controllable cooling flux (comparable to a radiative cooling flux of 100 W/m2) for the evaluation of thermosiphon performance. The testing apparatus is a chilled aluminum flat plate that has a controlled air gap separation relative to the flat panel surface of the thermosiphon to emulate radiative cooling. With an average of 105 W/m2 cooling flux, the 18 liters of water in the thermosiphon was cooled to an average temperature of 12.5 degrees C from an initial temperature of 22.2 degrees C in 2 h, with a cold collection efficiency of 96.8%. The results obtained have demonstrated the feasibility of using a single-phase thermosiphon for cold collection and storage of radiative cooling. Additionally, the effects of the thermosiphon operation conditions, such as tilt angle of the flat panel, initial water temperature, and cooling energy flux, on the performance have been experimentally investigated. Modular design of the single-phase thermosiphon gives flexibility for its scalability. A radiative cooling system with multiple thermosiphon modules is expected to play an important role in cooling buildings and power plant condensers.

  4. Inverse modeling of pumping tests to parameterize three-dimensional hydrofacies models

    Science.gov (United States)

    Medina-Ortega, P.; Morales-Casique, E.; Escolero-Fuentes, O.; Hernandez Espriu, A.

    2013-05-01

    We model the spatial distribution of hydrofacies in the aquifer of Mexico City and present a procedure for parameterizing those hydrofacies by inverse modeling of pumping tests . The aquifer is composed of a highly heterogeneous mixture of alluvial deposits and volcanic rocks. Lithological records from 111 production water wells are analyzed using indicator geostatistics. The different lithological categories are grouped into four hydrofacies, where a hydrofacies is a set of lithological categories which have similar hydraulic properties. An exponential variogram model was fitted to each hydrofacies by minimizing cross validation errors. The data set is then kriged to obtain the three-dimensional distribution of each hydrofacies within the alluvial aquifer of Mexico City. We present a procedure to parameterize the four hydrofacies by inverse modeling of two pumping tests and test the predictive capabilities of the inversion results by forward modeling of two more pumping tests.

  5. THEORETICAL FLOW MODEL THROUGH A CENTRIFUGAL PUMP USED FOR WATER SUPPLY IN AGRICULTURE IRRIGATION

    Directory of Open Access Journals (Sweden)

    SCHEAUA Fanel Dorel

    2017-05-01

    motion of the rotor. A theoretical model for calculating the flow of the working fluid through the interior of a centrifugal pump model is presented in this paper as well as the numerical analysis on the virtual model performed with the ANSYS CFX software in order to highlight the flow parameters and flow path-lines that are formed during centrifugal pump operation.

  6. Nuclear-pumped He/3/-Ar laser modeling

    Science.gov (United States)

    Wilson, J. W.; Deyoung, R. J.; Harries, W. L.

    1979-01-01

    A first-order model of He(3)-Ar 1.79-micron laser is developed, compared to experimental results, and used to explain the qualitative features of this system. Results indicate that direct excitation of the argon upper level is at best very inefficient for population inversion. For argon concentrations which give the most efficient laser operation, the He-3(n,p)He-3(n,p)He-3 energy is used to produce atomic He ions that quickly convert into He molecular ions. These molecular ions subsequently form argon atomic ions through charge transfer. The dominant pumping mechanism is collisional-radiative recombination of the argon atomic ion and subsequent radiative cascading into the upper laser level.

  7. Measurements of enlarged blood pump models using Laser Doppler Anemometer.

    Science.gov (United States)

    Chua, L P; Yu, S C; Leo, H L

    2000-01-01

    In an earlier study (Chua et al., 1998, 1999a), a 5:1 enlarged model of the Kyoto-NTN Magnetically Suspended Centrifugal Blood Pump (Akamatsu et al., 1995) with five different impeller blade profiles was designed and constructed. Their respective flow characteristics with respect to (1) the three different blade profile designs: forward, radial, and backward, (2) the number of blades used, and (3) the rotating speed were investigated. Among the five impeller designs, the results obtained suggested that impellers A and C designs should be adopted if higher head is required. Impellers A and C therefore were selected for the flow in between their blades to be measured using Laser Doppler Anemometer (LDA), so as to have a better understanding of the flow physics with respect to the design parameters.

  8. Simulation model of a variable-speed pumped-storage power plant in unstable operating conditions in pumping mode

    Science.gov (United States)

    Martínez-Lucas, G.; Pérez-Díaz, J. I.; Sarasúa, J. I.; Cavazzini, G.; Pavesi, G.; Ardizzon, G.

    2017-04-01

    This paper presents a dynamic simulation model of a laboratory-scale pumped-storage power plant (PSPP) operating in pumping mode with variable speed. The model considers the dynamic behavior of the conduits by means of an elastic water column approach, and synthetically generates both pressure and torque pulsations that reproduce the operation of the hydraulic machine in its instability region. The pressure and torque pulsations are generated each from a different set of sinusoidal functions. These functions were calibrated from the results of a CFD model, which was in turn validated from experimental data. Simulation model results match the numerical results of the CFD model with reasonable accuracy. The pump-turbine model (the functions used to generate pressure and torque pulsations inclusive) was up-scaled by hydraulic similarity according to the design parameters of a real PSPP and included in a dynamic simulation model of the said PSPP. Preliminary conclusions on the impact of unstable operation conditions on the penstock fatigue were obtained by means of a Monte Carlo simulation-based fatigue analysis.

  9. Study of a High-Pressure External Gear Pump with a Computational Fluid Dynamic Modeling Approach

    Directory of Open Access Journals (Sweden)

    Emma Frosina

    2017-07-01

    Full Text Available A study on the internal fluid dynamic of a high-pressure external gear pump is described in this paper. The pump has been analyzed with both numerical and experimental techniques. Starting from a geometry of the pump, a three-dimensional computational fluid dynamics (CFD model has been built up using the commercial code PumpLinx®. All leakages have been taken into account in order to estimate the volumetric efficiency of the pump. Then the pump has been tested on a test bench of Casappa S.p.A. Model results like the volumetric efficiency, absorbed torque, and outlet pressure ripple have been compared with the experimental data. The model has demonstrated the ability to predict with good accuracy the performance of the real pump. The CFD model has been also used to evaluate the effect on the pump performance of clearances in the meshing area. With the validated model the pressure inside the chambers of both driving and driven gears have been studied underlining cavitation in meshing fluid volume of the pump. For this reason, the model has been implemented in order to predict the cavitation phenomena. The analysis has allowed the detection of cavitating areas, especially at high rotation speeds and delivery pressure. Isosurfaces of the fluid volume have been colored as a function of the total gas fraction to underline where the cavitation occurs.

  10. Scaling up and controlling beam quality of flowing-gas diode pumped potassium laser with different pumping geometries: 3D CFD modeling

    Science.gov (United States)

    Yacoby, Eyal; Waichman, Karol; Sadot, Oren; Barmashenko, Boris D.; Rosenwaks, Salman

    2017-10-01

    Comprehensive analysis of the performance and beam quality of subsonic flowing-gas K diode-pumped alkali lasers (DPALs) with different pumping geometries, using 3D computational fluid dynamics model, is reported. The model is first applied to a K DPAL with transverse pumping and parameters similar to those of the 1.5 kW K DPAL [Pitz et al, Proc. SPIE 9729, 972902 (2016)] and the calculated results are in satisfactory agreement with the measurements. To study the possibility of scaling up the K DPAL the model is then applied to 100-kW class device with transverse and end pumping geometry. Dependence of the output power on the flow velocity and the pumping geometry is studied. Comparison between end and transverse pumping schemes shows that the output power is almost unaffected by the pumping geometry. However, the spatial intensity distribution of the output laser beam depends on the pumping geometry: it is uniform for the end pumping, whereas for the transverse pumping it is strongly non-uniform at high gas temperature (corresponding to large density of K atoms), becoming more uniform with temperature reduction. The model is applied to evaluation of the beam quality of flowing-gas K DPALs which strongly depends on the refractive index distribution in the gain medium. The beam divergence and the width of the intensity profile in the far field for the end pumping appear to be much smaller than for the transverse pumping. Wave front corrections of the transversely pumped device using cylindrical lens results in substantial reduction of the laser beam divergence and improvement of its quality which becomes comparable with that of the end pumped laser.

  11. Reliability Evaluation of a Single-phase H-bridge Inverter with Integrated Active Power Decoupling

    DEFF Research Database (Denmark)

    Tang, Junchaojie; Wang, Haoran; Ma, Siyuan

    2016-01-01

    Various power decoupling methods have been proposed recently to replace the DC-link Electrolytic Capacitors (E-caps) in single-phase conversion system, in order to extend the lifetime and improve the reliability of the DC-link. However, it is still an open question whether the converter level...... reliability becomes better or not, since additional components are introduced and the loading of the existing components may be changed. This paper aims to study the converter level reliability of a single-phase full-bridge inverter with two kinds of active power decoupling module and to compare...... it with the traditional passive DC-link solution. The converter level reliability is obtained by component level electro-thermal stress modeling, lifetime model, Weibull distribution, and Reliability Block Diagram (RBD) method. The results are demonstrated by a 2 kW single-phase inverter application....

  12. Field-circuit analysis and measurements of a single-phase self-excited induction generator

    Science.gov (United States)

    Makowski, Krzysztof; Leicht, Aleksander

    2017-12-01

    The paper deals with a single-phase induction machine operating as a stand-alone self-excited single-phase induction generator for generation of electrical energy from renewable energy sources. By changing number of turns and size of wires in the auxiliary stator winding, an improvement of performance characteristics of the generator were obtained as regards no-load and load voltage of the stator windings as well as stator winding currents of the generator. Field-circuit simulation models of the generator were developed using Flux2D software package for the generator with shunt capacitor in the main stator winding. The obtained results have been validated experimentally at the laboratory setup using the single-phase capacitor induction motor of 1.1 kW rated power and 230 V voltage as a base model of the generator.

  13. Current Harmonics from Single-Phase Grid-Connected Inverters

    DEFF Research Database (Denmark)

    Yang, Yongheng; Zhou, Keliang; Blaabjerg, Frede

    2016-01-01

    factor, or in the low voltage ride through mode with reactive current injection. In this paper, the mechanism of the harmonic current injection from grid-connected single-phase inverter systems is thus explored, and the analysis is conducted on single-phase PV systems. In particular, the analysis......-phase applications as a promising harmonic mitigation solution. Experiments on single-phase grid-connected systems have verified the correctness of the relevant analysis and also the effectiveness of the tailor-made control solution in terms of good harmonic mitigation....

  14. Modelling of Split Condenser Heat Pump: Optimization and Exergy Analysis

    DEFF Research Database (Denmark)

    Christensen, Stefan Wuust; Elmegaard, Brian; Markussen, Wiebke Brix

    2017-01-01

    This paper presents a numerical study of a split condenser heat pump (SCHP). The SCHP setup differs from a traditional heat pump (THP) setup in the way that two separate water streams on the secondary side of the condenser are heated in parallel to different temperature levels, whereas only one s...

  15. Hydraulic modeling test of intake pump in Ulchin nuclear power plant 5 and 6 units

    International Nuclear Information System (INIS)

    Kim, J. W.; Lee, D. S.

    2001-01-01

    In the intake structure of a nuclear power plant, undesirable pump operating characteristics such as vortices and non-uniform pump-approach flow around the pump bells take place frequently due to poorly-arranged intake geometry. Therefore, prior to the construction of intake structure or internal auxiliary facilities, hydraulic modeling test should be performed to predict the undesirable hydraulic phenomenon. In this study, a 1:10-scale, geometrically undistorted physical model was employed to investigate the hydraulic behavior and flow control devices were proposed to assure stable suction condition of pumps in the intake structure of Ulchin nuclear power plant 5,6 Units

  16. Hydraulic Performances of a Mixed-Flow Pump: Unsteady Inviscid Computations and Loss Models

    NARCIS (Netherlands)

    van Esch, B.P.M.; van Esch, B.P.M.; Kruyt, Nicolaas P.

    2001-01-01

    The hydraulic performance of an industrial mixed-flow pump is analyzed using a three-dimensional potential flow model to compute the unsteady flow through the entire pump configuration. Subsequently, several additional models that use the potential flow results are employed to assess the losses.

  17. Influence of the empirical coefficients of cavitation model on predicting cavitating flow in the centrifugal pump

    Directory of Open Access Journals (Sweden)

    Hou-lin Liu

    2014-03-01

    Full Text Available The phenomenon of cavitation is an unsteady flow, which is nearly inevitable in pump. It would degrade the pump performance, produce vibration and noise and even damage the pump. Hence, to improve accuracy of the numerical prediction of the pump cavitation performance is much desirable. In the present work, a homogenous model, the Zwart-Gerber-Belamri cavitation model, is considered to investigate the influence of the empirical coefficients on predicting the pump cavitation performance, concerning a centrifugal pump. Three coefficients are analyzed, namely the nucleation site radius, evaporation and condensation coefficients. Also, the experiments are carried out to validate the numerical simulations. The results indicate that, to get a precise prediction, the approaches of declining the initial bubble radius, the condensation coefficient or increasing the evaporation coefficient are all feasible, especially for declining the condensation coefficient, which is the most effective way.

  18. Influence of the empirical coefficients of cavitation model on predicting cavitating flow in the centrifugal pump

    Directory of Open Access Journals (Sweden)

    Liu Hou-lin

    2014-03-01

    Full Text Available The phenomenon of cavitation is an unsteady flow, which is nearly inevitable in pump. It would degrade the pump performance, produce vibration and noise and even damage the pump. Hence, to improve accuracy of the nu¬merical prediction of the pump cavitation performance is much desirable. In the present work, a homogenous model, the Zwart-Gerber-Belamri cavitation model, is considered to investigate the influence of the empirical coefficients on predicting the pump cavitation performance, concerning a centrifugal pump. Three coefficients are analyzed, namely the nucleation site radius, evaporation and condensation coefficients. Also, the experiments are carried out to validate the numerical simulations. The results indicate that, to get a precise prediction, the approaches of declining the initial bubble radius, the condensation coefficient or increasing the evaporation coefficient are all feasible, especially for de¬clining the condensation coefficient, which is the most effective way.

  19. Single-phase to three-phase power conversion interface

    Science.gov (United States)

    Wu, Jinn-Chang; Wang, Yung-Shan; Jou, Hurng-Liahng; Lu, Wei-Tso

    2016-07-01

    This study proposes a single-phase to three-phase power conversion interface which converts the power from a single-phase utility to three-phase power for a three-phase load. The proposed single-phase to three-phase power conversion interface comprises a bridge-type switch set, a set of three-phase inductors, a transformer set and a set of three-phase capacitors. A current-mode control controls the switching of bridge-type switch set, to generate a set of nonzero-sequence (NZS) currents and a set of zero-sequence (ZS) currents. The transformer set is used to decouple the NZS currents and the ZS currents. The NZS currents are used to generate a high-quality three-phase voltage that supplies power to a three-phase load. The ZS currents flow to the single-phase utility so that the utility current is sinusoidal and in phase with the utility voltage. Accordingly, only a bridge-type switch set is used in the single-phase to three-phase power conversion interface to simply the power circuit. A prototype is developed and tested to verify the performance of the proposed single-phase to three-phase power conversion interface.

  20. COMMIX-1AR/P: A three-dimensional transient single-phase computer program for thermal hydraulic analysis of single and multicomponent systems

    Energy Technology Data Exchange (ETDEWEB)

    Garner, P.L.; Blomquist, R.N.; Gelbard, E.M.

    1992-09-01

    The COMMIX-LAR/P computer program is designed for analyzing the steady-state and transient aspects of single-phase fluid flow and heat transfer in three spatial dimensions. This version is an extension of the modeling in COMMIX-lA to include multiple fluids in physically separate regions of the computational domain, modeling descriptions for pumps, radiation heat transfer between surfaces of the solids which are embedded in or surround the fluid, a keg model for fluid turbulence, and improved numerical techniques. The porous-medium formulation in COMMIX allows the program to be applied to a wide range of problems involving both simple and complex geometrical arrangements. The internal aspects of the COMMIX-LAR/P program are presented, covering descriptions of subprograms, variables, and files.

  1. COMMIX-1AR/P: A three-dimensional transient single-phase computer program for thermal hydraulic analysis of single and multicomponent systems

    International Nuclear Information System (INIS)

    Garner, P.L.; Blomquist, R.N.; Gelbard, E.M.

    1992-09-01

    The COMMIX-1AR/P computer program is designed for analyzing the steady-state and transient aspects of single-phase fluid flow and heat transfer in three spatial dimensions. This version is an extension of the modeling in COMMIX-1A to include multiple fluids in physically separate regions of the computational domain, modeling descriptions for pumps, radiation heat transfer between surfaces of the solids which are embedded in or surround the fluid, a k-var-epsilon model for fluid turbulence, and improved numerical techniques. The porous-medium formulation in COMMIX allows the program to be applied to a wide range of problems involving both simple and complex geometrical arrangements. The input preparation and execution procedures are presented for the COMMIX-1AR/P program and several postprocessor programs which produce graphical displays of the calculated results

  2. COMMIX-1AR/P: A three-dimensional transient single-phase computer program for thermal hydraulic analysis of single and multicomponent systems

    Energy Technology Data Exchange (ETDEWEB)

    Garner, P.L.; Blomquist, R.N.; Gelbard, E.M.

    1992-09-01

    The COMMIX-1AR/P computer program is designed for analyzing the steady-state and transient aspects of single-phase fluid flow and heat transfer in three spatial dimensions. This version is an extension of the modeling in COMMIX-1A to include multiple fluids in physically separate regions of the computational domain, modeling descriptions for pumps, radiation heat transfer between surfaces of the solids which are embedded in or surround the fluid, a k-[var epsilon] model for fluid turbulence, and improved numerical techniques. The porous-medium formulation in COMMIX allows the program to be applied to a wide range of problems involving both simple and complex geometrical arrangements. The input preparation and execution procedures are presented for the COMMIX-1AR/P program and several postprocessor programs which produce graphical displays of the calculated results.

  3. Performance Improvement of Single Phase Inverter using SPWM

    Science.gov (United States)

    Gavaskar Reddy, B., Dr; Maheswari, L., Dr; Ganeswari Kale, Adi

    2017-08-01

    This paper concentrates on modelling and simulation of single phase inverter as a frequency changer modulated by Pulse Width Modulation (PWM). An inverter is a circuit that converts DC sources to AC sources. Pulse Width Modulation is a method that utilization as an approach to abatement add up to harmonic distortion in inverter circuit. The model is executed utilizing MATLAB/Simulink software with the SimPower System Block Set in light of PC simulation. PC simulation assumes an imperative part in the plan, investigation, and assessment of force electronic converter and their controller. MATLAB is a successful instrument to examine a PWM inverter. Preferences of utilizing MATLAB are the accompanying: Faster reaction, accessibility of different simulation devices and utilitarian squares and the nonappearance of joining issues. Safe-replacement methodology need be actualized is to explain exchanging Transients. In this way, Insulated Gate Bipolar Transistor (IGBT) is use as exchanging gadgets. IGBT is ideal since it is anything but difficult to control and low misfortunes. The outcome from Simulink was checked utilizing MATLAB simulation.

  4. The Oak Ridge Heat Pump Models: I. A Steady-State Computer Design Model of Air-to-Air Heat Pumps

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, S.K. Rice, C.K.

    1999-12-10

    The ORNL Heat Pump Design Model is a FORTRAN-IV computer program to predict the steady-state performance of conventional, vapor compression, electrically-driven, air-to-air heat pumps in both heating and cooling modes. This model is intended to serve as an analytical design tool for use by heat pump manufacturers, consulting engineers, research institutions, and universities in studies directed toward the improvement of heat pump performance. The Heat Pump Design Model allows the user to specify: system operating conditions, compressor characteristics, refrigerant flow control devices, fin-and-tube heat exchanger parameters, fan and indoor duct characteristics, and any of ten refrigerants. The model will compute: system capacity and COP (or EER), compressor and fan motor power consumptions, coil outlet air dry- and wet-bulb temperatures, air- and refrigerant-side pressure drops, a summary of the refrigerant-side states throughout the cycle, and overall compressor efficiencies and heat exchanger effectiveness. This report provides thorough documentation of how to use and/or modify the model. This is a revision of an earlier report containing miscellaneous corrections and information on availability and distribution of the model--including an interactive version.

  5. Single phase cascaded H5 inverter with leakage current elimination for transformerless photovoltaic system

    DEFF Research Database (Denmark)

    Guo, Xiaoqiang; Jia, X.; Lu, Z.

    2016-01-01

    Leakage current reduction is one of the important issues for the transformelress PV systems. In this paper, the transformerless single-phase cascaded H-bridge PV inverter is investigated. The common mode model for the cascaded H4 inverter is analyzed. And the reason why the conventional cascade H...

  6. Identification of Dynamic Simulation Models for Variable Speed Pumped Storage Power Plants

    Science.gov (United States)

    Moreira, C.; Fulgêncio, N.; Silva, B.; Nicolet, C.; Béguin, A.

    2017-04-01

    This paper addresses the identification of reduced order models for variable speed pump-turbine plants, including the representation of the dynamic behaviour of the main components: hydraulic system, turbine governors, electromechanical equipment and power converters. A methodology for the identification of appropriated reduced order models both for turbine and pump operating modes is presented and discussed. The methodological approach consists of three main steps: 1) detailed pumped-storage power plant modelling in SIMSEN; 2) reduced order models identification and 3) specification of test conditions for performance evaluation.

  7. Observer based Model Identification of Heat Pumps in a Smart Grid

    DEFF Research Database (Denmark)

    Andersen, Palle; Pedersen, Tom S.; Nielsen, Kirsten M.

    2012-01-01

    . A part of a solution can be to take advantage of floor heat capacity in single-family houses using heat pumps.This large heat capacity makes it possible to move consumption without compromising the comfort of house residents. In a Danish research project a virtual power plant using centralized control...... of a large number of houses with heat pumps is established. In order to make the control algorithm a vital part is a dynamic model of each house. The model predicts the house indoor temperature when heat pump power and outdoor temperature is known. The model must be able to describe a large variety of heat...... pumps and houses. In the paper a house model and a method to identify the model is presented. The Kalman observer models are optimized using measurements from real houses....

  8. Energy system investment model incorporating heat pumps with thermal storage in buildings and buffer tanks

    International Nuclear Information System (INIS)

    Hedegaard, Karsten; Balyk, Olexandr

    2013-01-01

    Individual compression heat pumps constitute a potentially valuable resource in supporting wind power integration due to their economic competitiveness and possibilities for flexible operation. When analysing the system benefits of flexible heat pump operation, effects on investments should be taken into account. In this study, we present a model that facilitates analysing individual heat pumps and complementing heat storages in integration with the energy system, while optimising both investments and operation. The model incorporates thermal building dynamics and covers various heat storage options: passive heat storage in the building structure via radiator heating, active heat storage in concrete floors via floor heating, and use of thermal storage tanks for space heating and hot water. It is shown that the model is well qualified for analysing possibilities and system benefits of operating heat pumps flexibly. This includes prioritising heat pump operation for hours with low marginal electricity production costs, and peak load shaving resulting in a reduced need for peak and reserve capacity investments. - Highlights: • Model optimising heat pumps and heat storages in integration with the energy system. • Optimisation of both energy system investments and operation. • Heat storage in building structure and thermal storage tanks included. • Model well qualified for analysing system benefits of flexible heat pump operation. • Covers peak load shaving and operation prioritised for low electricity prices

  9. A Novel Single Phase Hybrid Switched Reluctance Motor Drive System

    DEFF Research Database (Denmark)

    Liang, Jianing; Xu, Guoqing; Jian, Linni

    2011-01-01

    phase boost converter is applied to improve the performance of this motor. It is easy to generate a double dclink voltage and dc-link voltage and switch both of them. The voltage of boost capacitor is self balance, so the protective circuit is not need to consider. The fast excitation mode helps hybrid......In this paper, a novel single phase hybrid switched reluctance motor(SRM) drive system is proposed. It integrated a single phase hybrid SRM and a novel single phase boost converter. This motor can reduce the number of phase switch. And the permanent magnet which is used in the motor can improve...... the performance and efficiency of SR motor. However, the inherent characteristic of this motor is that the negative torque is very sensitive with the excitation current near the turn-on angle. The slow excitation current limits the torque generation region and reduces the average torque. Therefore, a novel single...

  10. Ultrafast Switching Superjunction MOSFETs for Single Phase PFC Applications

    DEFF Research Database (Denmark)

    Hernandez Botella, Juan Carlos; Petersen, Lars Press; Andersen, Michael A. E.

    2014-01-01

    This paper presents a guide on characterizing state-of-the-art silicon superjunction (SJ) devices in the 600V range for single phase power factor correction (PFC) applications. The characterization procedure is based on a minimally inductive double pulse tester (DPT) with a very low intrusive...... investigates the latest SJ devices in order to set a reference for future research on improvement over silicon (Si) attained with the introduction of wide bandgap devices in single phase PFC applications. The obtained results show that the latest generation of SJ devices set a new benchmark for its wide...

  11. The Single-Phase ProtoDUNE Technical Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Abi, B. [Univ. of Padova (Italy); et al.

    2017-06-21

    ProtoDUNE-SP is the single-phase DUNE Far Detector prototype that is under construction and will be operated at the CERN Neutrino Platform (NP) starting in 2018. ProtoDUNE-SP, a crucial part of the DUNE effort towards the construction of the first DUNE 10-kt fiducial mass far detector module (17 kt total LAr mass), is a significant experiment in its own right. With a total liquid argon (LAr) mass of 0.77 kt, it represents the largest monolithic single-phase LArTPC detector to be built to date. It's technical design is given in this report.

  12. Two-phase coolant pump model of pressurized light water nuclear reactors

    International Nuclear Information System (INIS)

    Santos, G.A. dos; Freitas, R.L.

    1990-01-01

    The two-phase coolant pump model of pressurized light water nuclear reactors is an important point for the loss of primary coolant accident analysis. The homologous curves set up the complete performance of the pump and are input for accidents analysis thermal-hydraulic codes. This work propose a mathematical model able to predict the two-phase homologous curves where it was incorporated geometric and operational pump condition. The results were compared with the experimental tests data from literature and it has showed a good agreement. (author)

  13. Sodium pumping: pump problems

    International Nuclear Information System (INIS)

    Guer, M.; Guiton, P.

    Information on sodium pumps for LMFBR type reactors is presented concerning ring pump design, pool reactor pump design, secondary pumps, sodium bearings, swivel joints of the oscillating annulus, and thermal shock loads

  14. Pressure Drop Correlations of Single-Phase and Two-Phase Flow in Rolling Tubes

    International Nuclear Information System (INIS)

    Xia-xin Cao; Chang-qi Yan; Pu-zhen Gao; Zhong-ning Sun

    2006-01-01

    A series of experimental studies of frictional pressure drop for single phase and two-phase bubble flow in smooth rolling tubes were carried out. The tube inside diameters were 15 mm, 25 mm and 34.5 mm respectively, the rolling angles of tubes could be set as 10 deg. and 20 deg., and the rolling periods could be set as 5 s, 10 s and 15 s. Combining with the analysis of single-phase water motion, it was found that the traditional correlations for calculating single-phase frictional coefficient were not suitable for the rolling condition. Based on the experimental data, a new correlation for calculating single-phase frictional coefficient under rolling condition was presented, and the calculations not only agreed well with the experimental data, but also could display the periodically dynamic characteristics of frictional coefficients. Applying the new correlation to homogeneous flow model, two-phase frictional pressure drop of bubble flow in rolling tubes could be calculated, the results showed that the relative error between calculation and experimental data was less than ± 25%. (authors)

  15. A 2.5D Single Passage CFD Model for Centrifugal Pumps

    Science.gov (United States)

    Nakamura S.; Ding, W.; Yano, K.

    1998-01-01

    This paper describes the single passage model based on CFD to analyze the flow in blade passages of a centrifugal pump. The model consists of the flow passage between two impeller blades and the spaces in the inlet eye as well as in the volute. The incompressible Navier-Stokes equations in the conservation form are solved by a finite difference method. The code is designed to investigate the velocity and pressure distributions and intended to investigate how the pump design affects fluid flow through the rotor as well as the pump performance. An early part of the paper investigates the behavior of the model as well as validity of the assumptions made in the model. Then, applications to a rotodynamic heart pump are presented.

  16. Improved Modeling of Residential Air Conditioners and Heat Pumps for Energy Calculations

    Energy Technology Data Exchange (ETDEWEB)

    Cutler, D.; Winkler, J.; Kruis, N.; Christensen, C.; Brendemuehl, M.

    2013-01-01

    This report presents improved air conditioner and heat pump modeling methods in the context of whole-building simulation tools, with the goal of enabling more accurate evaluation of cost effective equipment upgrade opportunities and efficiency improvements in residential buildings.

  17. Energy-saving control model of inverter for centrifugal pump systems

    Directory of Open Access Journals (Sweden)

    Yin Luo

    2015-06-01

    Full Text Available The inverter control strategy is the key to pump energy-saving operation and should be established based on the current system configurations and system requirements, which is not the case in practice. As a result, the characteristics of pump system requirements and a combination pump with inverter were studied, and the mathematical models were established. A new model for an optimal inverter control strategy based on the current system configurations and system requirements was then established, and a method combining golden section search and genetic algorithm was formulated to solve this optimal model. This model sets up an optimal inverter control strategy to increase the efficiency of pump operation following a process line near the minimum requirements to improve operation conditions. The implementation difficulty of the control law was also reduced. Finally, the optimized model was applied to an industrial circulating pump system, and the result showed that the model can not only determine the optimal inverter control strategy but also evaluate the current operation situation of the pump configuration and determine the energy-saving potential for the current configuration, which can aid in the subsequent energy-saving reconstruction.

  18. the steady-state performance characteristics of single phase transfer

    African Journals Online (AJOL)

    2012-11-03

    Nov 3, 2012 ... The paper reports the derivation of the steady- state equivalent circuit of a single phase transfer ... series opposition between the two halves of the ma- ..... from its equivalent circuit of fig 6 for different values of slip. Impedance due to forward field. Zf = Rf + jXf = Rr. 2(2s - 1). + jxr. 2. (19) in parallel with jxm. 2.

  19. An Asymmetrical Space Vector Method for Single Phase Induction Motor

    DEFF Research Database (Denmark)

    Cui, Yuanhai; Blaabjerg, Frede; Andersen, Gert Karmisholt

    2002-01-01

    Single phase induction motors are the workhorses in low-power applications in the world, and also the variable speed is necessary. Normally it is achieved either by the mechanical method or by controlling the capacitor connected with the auxiliary winding. Any above method has some drawback which...

  20. Improvement of Torque Production in Single-Phase Induction Motors ...

    African Journals Online (AJOL)

    Existing single phase induction motors exhibit low starting torque. Moreover, during accelerating time and at steady state, they produce a significant level of torque pulsations which gives rise to noise and vibration in the machine. As part of efforts to mitigate these problems, a performance improvement strategy using a PWM ...

  1. A simple output voltage control scheme for single phase wavelet ...

    African Journals Online (AJOL)

    DR OKE

    Wavelet based techniques have been extensively used in various power engineering applications. Recently, wavelet has also been proposed to generate switching signal for single-phase pulse-width-modulated (PWM) dc-ac inverter. The main advantage of the wavelet modulated (WM) scheme is that a single synthesis ...

  2. experimental implementation of single-phase, three-level, sinusoidal

    African Journals Online (AJOL)

    Experimental Implementation of SPWM VSI with R-L Load. 3. Figure 2: Switching pattern of the proposed single-phase, three-level PWM inverter. Figure 3: Prototype setup. (a) Power circuits for both inverters. (b) Logic and Driver circuits. Nigerian Journal of Technology. Vol. 31, No. 1, March 2012.

  3. A single phase photovoltaic inverter control for grid connected system

    Indian Academy of Sciences (India)

    This paper presents a control scheme for single phase grid connected photovoltaic (PV) system operating under both grid connected and isolated grid mode. The control techniques include voltage and current control of grid-tie PV inverter. During grid connected mode, grid controls the amplitude and frequency of the PV ...

  4. Load compensation for single phase system using series active filter ...

    African Journals Online (AJOL)

    In this paper a new control strategy for series active filter has been proposed for improvement of power quality problems in single phase system. Since the non linear loads in the system comprises of both voltage source harmonic and current source harmonic loads and the dominancy of each type of load varies from time to ...

  5. Control of Single-Stage Single-Phase PV inverter

    DEFF Research Database (Denmark)

    Ciobotaru, Mihai; Teodorescu, Remus; Blaabjerg, Frede

    2005-01-01

    In this paper the issue of control strategies for single-stage photovoltaic (PV) inverter is addressed. Two different current controllers have been implemented and an experimental comparison between them has been made. A complete control structure for the single-phase PV system is also presented...

  6. Modelación en coordenadas de fase del transformador monofásico con derivación central en el secundario; Modeling in phase-coordinates of the single-phase transformer with center tap in the secondary winding

    Directory of Open Access Journals (Sweden)

    Ignacio - Pérez Abril

    2013-10-01

    Full Text Available Existe un modelo en la literatura para representar el transformador monofásico con derivación central en el secundario. No obstante, dicho modelo representa toda la impedancia del transformador en el secundario, lo que difiere de la realidad. La distribución de la impedancia del transformador entre el primario y ambas secciones del secundario tiene una gran influencia en la magnitud de la corriente de cortocircuito de una fase a la derivación central del secundario. Esta corriente supera ampliamente la corriente de cortocircuito de fase a fase en transformadores con devanados entrelazados. El presente trabajo desarrolla el modelo en coordenadas de fase del transformador monofásico con derivación central en el secundario. El modelo desarrollado se prueba con varios ejemplos que demuestran la conveniencia de emplear el modelo presentado para analizar la carga desigual de ambas secciones del devanado secundario o el cortocircuito de una fase a la derivación central del secundario.There exists a model in the literature to representing the single-phase transformer with center tap in the secondary winding. However, this model represents all the impedance of the transformer in the secondary winding, which differs from practice. The distribution of the impedance between primary and the both sections of the secondary winding has a great influence over the magnitude of the short circuit current from a phase to the center tap. This current is much greater than the phase to phase short circuit current in transformers with interlaced windings. The present paper develops a model in phase coordinates for the single-phase transformer with center tap in the secondary winding. The developed model is tested with several examples that shown the convenience of the use of the presented model to analyze the unequal load in both sections of the secondary or the short circuit from a phase to the center tap of the secondary.

  7. Modeling technique of capacitive discharge pumping of metal vapor lasers for electrode capacitance optimization.

    Science.gov (United States)

    Gubarev, F A; Evtushenko, G S; Vuchkov, N K; Sukhanov, V B; Shiyanov, D V

    2012-05-01

    To estimate optimum gas discharge tube (GDT) electrode capacitance of metal vapor lasers (MVLs) pumped by a longitudinal capacitive discharge, we offer to use series connection of capacitors to the electrodes of a conventionally pumped GDT with inner electrodes. It has been demonstrated that the maximum output power in CuBr lasers is obtained when the capacitances of high-voltage and ground electrodes are equal. When using a model circuit an average output power reaches 12 W that suggests the possibility of generating high average output power (>10 W) in MVLs pumped using a capacitive discharge.

  8. LOFT test support branch data abstract report: one-sixth scale model BWR jet pump test

    International Nuclear Information System (INIS)

    Crapo, H.S.

    1979-01-01

    Pump performance data are presented for a 1/6 scale model jet pump in tests conducted at the LOFT Test Support Blowdown Facility. Steady-state subcooled pump characterization tests were performed over a wide range of forward and reverse flow conditions, both at room temperature, and at elevated temperature (555 0 K). Blowdown tests were also performed to obtain two-phase performance data in configurations simulating the flow patterns in the intact and broken loops of a BWR during a recirculation line break transient

  9. Scale Effect Features During Simulation Tests of 3D Printer-Made Vane Pump Models

    Directory of Open Access Journals (Sweden)

    A. I. Petrov

    2015-01-01

    Full Text Available The article "Scale effect features during simulation tests of 3D printer-made vane pump models" discusses the influence of scale effect on translation of pump parameters from models, made with 3D-prototyping methods, to full-scale pumps. Widely spread now 3D-printer production of pump model parts or entire layouts can be considered to be the main direction of vane pumps modeling. This is due to the widespread development of pumps in different CAD-systems and the significant cost reduction in manufacturing such layouts, as compared to casting and other traditional methods.The phenomenon of scale effect in vane hydraulic machines, i.e. violation of similarity conditions when translating pump parameters from model to full-scale pumps is studied in detail in the theory of similarity. However, as the experience in the 3d-printer manufacturing of models and their testing gains it becomes clear that accounting large-scale effect for such models has a number of differences from the conventional techniques. The reason for this is the features of micro and macro geometry of parts made in different kinds of 3D-printers (extrusive, and powder sintering methods, ultraviolet light, etc..The article considers the converting features of external and internal mechanical losses, leakages, and hydraulic losses, as well as the specifics of the balance tests for such models. It also presents the basic conversion formulas describing the factors affecting the value of these losses. It shows photographs of part surfaces of models, manufactured by 3D-printer and subjected to subsequent machining. The paper shows results of translation from several pump models (layouts to the full-scale ones, using the techniques described, and it also shows that the error in translation efficiency does not exceed 1.15%. The conclusion emphasizes the importance of the balance tests of models to accumulate statistical data on the scale effect for pump layouts made by different 3D

  10. Evaluation of 600V Superjunction Devices in Single Phase PFC Applications under CCM Operation

    DEFF Research Database (Denmark)

    Hernandez Botella, Juan Carlos; Petersen, Lars Press; Andersen, Michael A. E.

    2014-01-01

    This paper pr esents a power density/efficiency evaluation in single phase power factor correction (PFC) applications operating in continuous conduction mode (CCM). The comparison is based on semiconductor dynamic characterization and a mathematical model for prediction of the conducted electroma......This paper pr esents a power density/efficiency evaluation in single phase power factor correction (PFC) applications operating in continuous conduction mode (CCM). The comparison is based on semiconductor dynamic characterization and a mathematical model for prediction of the conducted...... electromagnetic interference (EMI). The dynamic characterization is based on a low inductive double pulse tester (DPT). The measured switching energy is used in order to evaluate the devices performance in a conventional PFC. This data is used together with the mathematical model for prediction of the conducted...... electromagnetic interference. The method allows comparing different devices and evaluating the performance as a function of the PFC power density and efficiency....

  11. PRINCIPLES OF DEVELOPMENT MATHEMATICAL MODEL FOR RESEARCHING OF NONPULSATILE FLOW PUMP AND CARDIAC SYSTEM

    Directory of Open Access Journals (Sweden)

    I. V. Bykov

    2013-01-01

    Full Text Available Aim. The presented research uncovers the using of mathematical modeling methods for cardio-vascular system and axial blood pump interaction analysis under heart failure with combined valve pathology. The research will pro- vide data for automated pump control algorithm synthesis. Materials and methods. Mathematical model is build up by using experiments results from mock cardio-vascular circulation loop and mathematical representation of Newtonian fluid dynamics in pulsing circulation loop. The model implemented in modeling environment Simulink (Matlab. Results. Authors implemented mathematical model which describe cardio-vascular system and left-ven- tricular assistive device interaction for intact conditions. Values of parameters for intact conditions were acquired in the experiments on animals with implanted axial pump, experiments were conducted in FRCTAO. The model was verified by comparison of instantaneous blood flowrate values in experiments and in model. Conclusion. The paper present implemented mathematical model of cardio-vascular system and axial pump interaction for intact conditions, where the pump connected between left ventricle and aorta. In the next part of research authors will use the presented model to evaluate using the biotechnical system in conditions of heart failure and valve pathology. 

  12. Theoretical model and simulations for a cw exciplex pumped alkali laser.

    Science.gov (United States)

    Huang, Wei; Tan, Rongqing; Li, Zhiyong; Lu, Xiaochuan

    2015-12-14

    The Exciplex Pumped Alkali Laser (XPAL) system, which is similar to DPAL (Diode Pumped Alkali vapor Laser), has been demonstrated in mixtures of Cs vapor, Ar, with and without ethane. Unlike DPAL, it uses the broadband absorption blue satellite of the alkali D2 line, created by naturally occuring collision pairs. For example, Cs-Ar collision pairs have an absorption width which is as wide as the one of commercial semiconductor diode lasers. A continuous wave XPAL four-level theoretical model is presented in this paper. More factors are considered, such as the spectral dependence of pumped laser absorption for broadband pumping and the longitudinal population variation. Some intra-cavity details, such as longitudinal distributions of pumped laser and alkali laser, can also be solved well. The predictions of optical-to-optical efficiency as a function of temperature and pumped laser intensity are presented. The model predicts that there is an optimum value of temperature or pumped laser intensity. The analysis of the influence of cell length on optical-to-optical efficiency shows that a better performance can be achieved when using longer cell. The prediction of influence of Ar concentration and reflectivity of output coupler shows that higher optical-to-optical efficiency could be achieved if lower reflectivity of output coupler and higher Ar concentration are used. The optical-to-optical efficiency as high as 84% achieved by optimizing configuration with the pumped intensity of 5 × 10⁷ W/cm² presented shows that broadband pumped four-level XPAL system has a potential of high optical-to-optical efficiency.

  13. Dynamic modelling of a PV pumping system with special consideration on water demand

    International Nuclear Information System (INIS)

    Campana, Pietro Elia; Li, Hailong; Yan, Jinyue

    2013-01-01

    Highlights: ► Evaluation of water demand and solar energy is essential for PV pumping system. ► The design for a PV water pumping system has been optimized based on dynamic simulations. ► It is important to conduct dynamic simulations to check the matching between water demand and water supply. ► AC pump driven by the fixed PV array is the most cost-effective solution. - Abstract: The exploitation of solar energy in remote areas through photovoltaic (PV) systems is an attractive solution for water pumping for irrigation systems. The design of a photovoltaic water pumping system (PVWPS) strictly depends on the estimation of the crop water requirements and land use since the water demand varies during the watering season and the solar irradiation changes time by time. It is of significance to conduct dynamic simulations in order to achieve the successful and optimal design. The aim of this paper is to develop a dynamic modelling tool for the design of a of photovoltaic water pumping system by combining the models of the water demand, the solar PV power and the pumping system, which can be used to validate the design procedure in terms of matching between water demand and water supply. Both alternate current (AC) and direct current (DC) pumps and both fixed and two-axis tracking PV array were analyzed. The tool has been applied in a case study. Results show that it has the ability to do rapid design and optimization of PV water pumping system by reducing the power peak and selecting the proper devices from both technical and economic viewpoints. Among the different alternatives considered in this study, the AC fixed system represented the best cost effective solution

  14. Analytical thermal model for end-pumped solid-state lasers

    Science.gov (United States)

    Cini, L.; Mackenzie, J. I.

    2017-12-01

    Fundamentally power-limited by thermal effects, the design challenge for end-pumped "bulk" solid-state lasers depends upon knowledge of the temperature gradients within the gain medium. We have developed analytical expressions that can be used to model the temperature distribution and thermal-lens power in end-pumped solid-state lasers. Enabled by the inclusion of a temperature-dependent thermal conductivity, applicable from cryogenic to elevated temperatures, typical pumping distributions are explored and the results compared with accepted models. Key insights are gained through these analytical expressions, such as the dependence of the peak temperature rise in function of the boundary thermal conductance to the heat sink. Our generalized expressions provide simple and time-efficient tools for parametric optimization of the heat distribution in the gain medium based upon the material and pumping constraints.

  15. Uncertainties in modelling and scaling of critical flows and pump model in TRAC-PF1/MOD1

    International Nuclear Information System (INIS)

    Rohatgi, U.S.; Yu, Wen-Shi.

    1987-01-01

    The USNRC has established a Code Scalability, Applicability and Uncertainty (CSAU) evaluation methodology to quantify the uncertainty in the prediction of safety parameters by the best estimate codes. These codes can then be applied to evaluate the Emergency Core Cooling System (ECCS). The TRAC-PF1/MOD1 version was selected as the first code to undergo the CSAU analysis for LBLOCA applications. It was established through this methodology that break flow and pump models are among the top ranked models in the code affecting the peak clad temperature (PCT) prediction for LBLOCA. The break flow model bias or discrepancy and the uncertainty were determined by modelling the test section near the break for 12 Marviken tests. It was observed that the TRAC-PF1/MOD1 code consistently underpredicts the break flow rate and that the prediction improved with increasing pipe length (larger L/D). This is true for both subcooled and two-phase critical flows. A pump model was developed from Westinghouse (1/3 scale) data. The data represent the largest available test pump relevant to Westinghouse PWRs. It was then shown through the analysis of CE and CREARE pump data that larger pumps degrade less and also that pumps degrade less at higher pressures. Since the model developed here is based on the 1/3 scale pump and on low pressure data, it is conservative and will overpredict the degradation when applied to PWRs

  16. Central model predictive control of a group of domestic heat pumps, case study for a small district

    NARCIS (Netherlands)

    van Leeuwen, Richard Pieter; Fink, J.; Smit, Gerardus Johannes Maria; Helfert, Markus; Krempels, Karl-Heinz; Donnellan, Brian; Klein, Cornel

    2015-01-01

    In this paper we investigate optimal control of a group of heat pumps. Each heat pump provides space heating and domestic hot water to a single household. Besides a heat pump, each house has a buffer for domestic hot water and a floor heating system for space heating. The paper describes models and

  17. Statistical modelling of Fat, Oil and Grease (FOG) deposits in wastewater pump sumps.

    Science.gov (United States)

    Nieuwenhuis, Eva; Post, Johan; Duinmeijer, Alex; Langeveld, Jeroen; Clemens, François

    2018-05-15

    The accumulation of FOG (Fat, Oil and Grease) deposits in sewer pumping stations results in an increase in maintenance costs, malfunctioning of pumps and, a potential increase of wastewater spills in receiving open water bodies. It is thought that a variety of parameters (e.g. geometry of the pump sump, pump operation, socioeconomic parameters of the catchment) influences the built-up of FOG. Based on a database containing data of 126 pumping stations located in five Dutch municipalities a statistical model was built. It is shown that 3 parameters are most significant in explaining the occurrence of FOG deposits: mean income of the population in a catchment, the amount of energy (kinetic and potential) per m 3 per day and the density of restaurants, bars and hotels in a catchment. Further it is shown that there are significant differences between municipalities that can be traced back to the local 'design paradigm'. For example, in Amsterdam, the design philosophy of discharging in the pump sump under the water surface (and hence maintaining a low level of turbulence in the pump sump) results in an increase of the probability of the formation of FOG. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. Completely two-dimensional model for analysis of characteristics of linear induction cylindrical pump

    International Nuclear Information System (INIS)

    Kirillov, I.R.; Obukhov, D.M.

    2005-01-01

    One introduces a completely two-dimensional mathematical model to calculate characteristics of induction magnetohydrodynamic (MHD) machines with a cylindrical channel. On the basis of the numerical analysis one obtained a pattern of liquid metal flow in a electromagnetic pump at presence of the MHD-instability characterized by initiation of large-scale vortices propagating longitudinally and azimuthally. Comparison of the basic calculated characteristics of pump with the experiment shows their adequate qualitative and satisfactory quantitative coincidence [ru

  19. Model based fault diagnosis in a centrifugal pump application using structural analysis

    DEFF Research Database (Denmark)

    Kallesøe, C. S.; Izadi-Zamanabadi, Roozbeh; Rasmussen, Henrik

    2004-01-01

    A model based approach for fault detection and isolation in a centrifugal pump is proposed in this paper. The fault detection algorithm is derived using a combination of structural analysis, Analytical Redundant Relations (ARR) and observer designs. Structural considerations on the system are used...... it to an industrial benchmark. The benchmark tests have shown that the algorithm is capable of detection and isolation of five different faults in the mechanical and hydraulic parts of the pump....

  20. Effect of palytoxin on the sodium–potassium pump: model and simulation

    International Nuclear Information System (INIS)

    Rodrigues, Antônio M; Infantosi, Antonio F C; Almeida, Antônio-Carlos G

    2008-01-01

    We propose a reaction model for the palytoxin–sodium–potassium (PTX–Na + /K + ) pump complex. The model, which is similar to the Albers–Post model for Na + /K + -ATPase, is used to elucidate the effect of PTX on Na + /K + -ATPase during the enzyme interactions with Na + and/or K + ions. Conformational substates and reactions for the pump are incorporated into the Albers–Post model to represent enzymes with or without bound PTX. A mathematical model based on the reaction scheme is used in simulations modeling experimental studies of PTX-induced ionic currents. Our simulations suggest that (i) extracellular Na + as well as K + promotes PTX-induced channel blockage; (ii) extracellular K + accelerates PTX unbinding; and (iii) K + occlusion in the PTX–pump complex is essential for describing the PTX-induced current dynamics

  1. Intelligent Hydraulic Actuator and Exp-based Modelling of Losses in Pumps and .

    DEFF Research Database (Denmark)

    Zhang, Muzhi

    A intelligent fuzzy logic self-organising PD+I controller for a gearrotor hydraulic motor was developed and evaluated. Furthermore, a experimental-based modelling methods with a new software tool 'Dynamodata' for modelling of losses in hydraulic motors and pumps was developed.......A intelligent fuzzy logic self-organising PD+I controller for a gearrotor hydraulic motor was developed and evaluated. Furthermore, a experimental-based modelling methods with a new software tool 'Dynamodata' for modelling of losses in hydraulic motors and pumps was developed....

  2. Energy consumption modeling of air source electric heat pump water heaters

    International Nuclear Information System (INIS)

    Bourke, Grant; Bansal, Pradeep

    2010-01-01

    Electric heat pump air source water heaters may provide an opportunity for significant improvements in residential water heater energy efficiency in countries with temperate climates. As the performance of these appliances can vary widely, it is important for consumers to be able to accurately assess product performance in their application to maximise energy savings and ensure uptake of this technology. For a given ambient temperature and humidity, the performance of an air source heat pump water heater is strongly correlated to the water temperature in or surrounding the condenser. It is therefore important that energy consumption models for these products duplicate the real-world water temperatures applied to the heat pump condenser. This paper examines a recently published joint Australian and New Zealand Standard, AS/NZS 4234: 2008; Heated water systems - Calculation of energy consumption. Using this standard a series TRNSYS models were run for several split type air source electric heat pump water heaters. An equivalent set of models was then run utilizing an alternative water use pattern. Unfavorable errors of up to 12% were shown to occur in modeling of heat pump water heater performance using the current standard compared to the alternative regime. The difference in performance of a model using varying water use regimes can be greater than the performance difference between models of product.

  3. Model test research on effect of flow accelerating-board in a pumping station

    Science.gov (United States)

    Ding, Yuan; Li, TongChun; Liu, XiaoQing; Guo, Yun; Zhou, MinZhe

    2017-09-01

    Generally, the sedimentation in the forebay of pumping station may result in bad flow patterns, which will decrease efficiency of pump device and cause the vibration of pump house and units, or other safety problems. To research the improvement of this impact in an actual project, a physical model test was established for the original scheme of one pumping station. One part of results show that the flow velocity in the channel of regulating-pool is low under the high-water level condition, and it's easy to cause the sedimentation in the regulating-pool. According to this problem, we propose a flow accelerating-board scheme for the regulating-pool. The final results show that this scheme could effectively increase the flow velocity at the bottom and reduce the sedimentation in the regulating-pool. Although the hydraulic loss of regulating-pool increased, it could be able to satisfy the design requirements.

  4. Overview of Single-Phase Grid-Connected Photovoltaic Systems

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede

    2017-01-01

    A continuous booming installation of solar photovoltaic (PV) systems has been witnessed worldwide. It is mainly driven by the imperative demand of “clean” power generation from renewables. Grid-connected PV systems will thus become an even more active player in the future mixed power systems, which...... systems. This chapter thus gives an overview of the advancement of power electronics converters in single-phase grid-connected PV systems, being commonly used in residential applications. Demands to single-phase grid-connected PV systems and the general control strategies are also addressed...... are linked together by a vast of power electronics converters and the power grid. In order to achieve a reliable and efficient power generation from PV systems, more stringent demands have been imposed on the entire PV system. It, in return, advances the development of the power converter technology in PV...

  5. Instantaneous power flow determination for single-phase UPFC

    Energy Technology Data Exchange (ETDEWEB)

    Dobrucky, B.; Drozdy, S.; Pokorny, M.; Pavlanin, R. [Zilina Univ., Zilina (Slovakia)

    2007-07-01

    The parallel shunt active filter in a unified power flow conditioner (UPFC) can filter and compensate the reactive power of basic and higher current harmonics. This paper reported on a study in which a new theory of orthogonal transform was used to control a single-phase UPFC system and transform it into a two-axes system. In addition to estimating the load current phase shifts, the study also determined the instantaneous active and reactive powers. The new theory is based on the premise that ordinary single-phase quantity can be complemented by a virtual fictitious phase so that both of them will create an orthogonal system, as is usual in three-phase systems. The theory uses efficient methods of analysis, such as time-sub-optimal determination of fundamental harmonics; average- and/or root-mean-square values; or instantaneous reactive power methods. The load current phase shift can be used to compensate for voltage drops. This paper outlined a practical application of the method in a case of active and reactive power determination for single-phase UPFC. It also presented some examples of the successful simulation experiments results focused on regulation output voltage of UPFC. 9 refs., 13 figs., 1 appendix.

  6. Power decoupling with autonomous reference generation for single-phase differential inverters

    DEFF Research Database (Denmark)

    Yao, Wenli; Zhang, Xiaobin; Wang, Xiongfei

    2015-01-01

    The second-harmonic power ripple in single-phase inverter may introduce the issue of low reliability and low power density. In order to replace the bulky dc-link capacitor, an alternative approach is to use active power decoupling so that the ripple power can be diverted into other energy storages...... are used for realizing an improved power decoupling control, capacitor voltage and inductor current regulation. By substituting the corresponding parameter into unified model, the proposed control loop can be applied to different inverter types (Buck, Buck-Boost and Boost). Finally, detailed laboratory....... However, the performance of existing active power decoupling methods depends heavily on certain control references, which unfortunately are parameter dependent. In this paper an autonomous reference generation technique is proposed for single phase differential inverter without relying on the system...

  7. Model and simulation of Na+/K+ pump phosphorylation in the presence of palytoxin.

    Science.gov (United States)

    Rodrigues, Antônio M; Almeida, Antônio-Carlos G; Infantosi, Antonio F C; Teixeira, Hewerson Z; Duarte, Mario A

    2008-02-01

    The ATP hydrolysis reactions responsible for the Na(+)/K(+)-ATPase phosphorylation, according to recent experimental evidences, also occur for the PTX-Na(+)/K(+) pump complex. Moreover, it has been demonstrated that PTX interferes with the enzymes phosphorylation status. However, the reactions involved in the PTX-Na(+)/K(+) pump complex phosphorylation are not very well established yet. This work aims at proposing a reaction model for PTX-Na(+)/K(+) pump complex, with similar structure to the Albers-Post model, to contribute to elucidate the PTX effect over Na(+)/K(+)-ATPase phosphorylation and dephosphorylation. Computational simulations with the proposed model support several hypotheses and also suggest: (i) phosphorylation promotes an increase of the open probability of induced channels; (ii) PTX reduces the Na(+)/K(+) pump phosphorylation rate; (iii) PTX may cause conformational changes to substates where the Na(+)/K(+)-ATPase may not be phosphorylated; (iv) PTX can bind to substates of the two principal states E1 and E2, with highest affinity to phosphorylated enzymes and with ATP bound to its low-affinity sites. The proposed model also allows previewing the behavior of the PTX-pump complex substates for different levels of intracellular ATP concentrations.

  8. Investigation on a Novel Discontinuous Pulse-Width Modulation Algorithm for Single-phase Voltage Source Rectifier

    DEFF Research Database (Denmark)

    Qu, Hao; Yang, Xijun; Guo, Yougui

    2014-01-01

    Single-phase voltage source converter (VSC) is an important power electronic converter (PEC), including single-phase voltage source inverter (VSI), single-phase voltage source rectifier (VSR), single-phase active power filter (APF) and single-phase grid-connection inverter (GCI). Single-phase VSC...

  9. Hydraulic model tests for 100D type primary reactor coolant pump

    International Nuclear Information System (INIS)

    Takezawa, Kiyomi; Miyamoto, Satoshi; Tagawa, Masashi; Yamada, Isao; Yoshida, Yoshiki; Uehara, Sakuichiro.

    1985-01-01

    We are now energetically promoting the design and development for domestic production of the 100D type (for 50 Hz) as the primary reactor coolant pump for units No. 1, 2 at the Tomari Nuclear Power Station of the Hokkaido Electric Power Co. In this connection, a hydraulic model test was conducted on a 1/2.54 scale model to evaluate the hydraulic characteristics of the pump, which is essential for the basic structure and reliability of the pump, and the fluid exciting force, which is indispensable for evaluating the soundness of the shafting. As a result, these characteristics were determined and the hydraulic characteristics were improved, while a hydraulic design base was established and the validity of the design was confirmed. This paper reports the results of the hydraulic model test, and discusses the optimum hydraulic structure for the designing of actual units to be manufactured henceforth. (author)

  10. A new beating-heart off-pump coronary artery bypass grafting training model

    NARCIS (Netherlands)

    Bouma, Wobbe; Kuijpers, Michiel; Bijleveld, Aanke; De Maat, Gijs E.; Koene, Bart M.; Erasmus, Michiel E.; Natour, Ehsan; Mariani, Massimo A.

    OBJECTIVES: Training models are essential in mastering the skills required for off-pump coronary artery bypass grafting (OPCAB). We describe a new, high-fidelity, effective and reproducible beating-heart OPCAB training model in human cadavers. METHODS: Human cadavers were embalmed according to the

  11. A predictive model for smart control of a domestic heat pump and thermal storage

    NARCIS (Netherlands)

    van Leeuwen, Richard Pieter; Gebhardt, I.; de Wit, J.B.; Smit, Gerardus Johannes Maria

    The purpose of this paper is to develop and validate a predictive model of a thermal storage which is charged by a heat pump and used for domestic hot water supply. The model is used for smart grid control purposes and requires measurement signals of flow and temperature at the inlet and outlet of

  12. Model based analysis of the time scales associated to pump start-ups

    Energy Technology Data Exchange (ETDEWEB)

    Dazin, Antoine, E-mail: antoine.dazin@lille.ensam.fr [Arts et métiers ParisTech/LML Laboratory UMR CNRS 8107, 8 bld Louis XIV, 59046 Lille cedex (France); Caignaert, Guy [Arts et métiers ParisTech/LML Laboratory UMR CNRS 8107, 8 bld Louis XIV, 59046 Lille cedex (France); Dauphin-Tanguy, Geneviève, E-mail: genevieve.dauphin-tanguy@ec-lille.fr [Univ Lille Nord de France, Ecole Centrale de Lille/CRISTAL UMR CNRS 9189, BP 48, 59651, Villeneuve d’Ascq cedex F 59000 (France)

    2015-11-15

    Highlights: • A dynamic model of a hydraulic system has been built. • Three periods in a pump start-up have been identified. • The time scales of each period have been estimated. • The parameters affecting the rapidity of a pump start-up have been explored. - Abstract: The paper refers to a non dimensional analysis of the behaviour of a hydraulic system during pump fast start-ups. The system is composed of a radial flow pump and its suction and delivery pipes. It is modelled using the bond graph methodology. The prediction of the model is validated by comparison to experimental results. An analysis of the time evolution of the terms acting on the total pump pressure is proposed. It allows for a decomposition of the start-up into three consecutive periods. The time scales associated with these periods are estimated. The effects of parameters (angular acceleration, final rotation speed, pipe length and resistance) affecting the start-up rapidity are then explored.

  13. Predicting contaminant concentration at a pumping well with method combining statistical and mathematical models

    Science.gov (United States)

    Lim, J.; Bae, G.; Kaown, D.; Lee, K.

    2008-12-01

    In predicting contamination of groundwater, both the statistical and mathematical modeling methods are used in combination with one another with the aim of taking the advantage of each method. With a mathematical model based on the backward transport equation, probabilistic capture zones of pumping wells are delineated. And these capture zones are used as a buffer zone of each pumping well for a statistical regression model. Tobit regression model is used to investigate the influence of land use on contaminant concentration at a pumping well. Using probabilistic capture zones as buffer zones instead of circular zones, flow and transport regime near pumping wells can be considered in the regression model as well as different types of land use. The method is applied to a small agricultural basin in Chuncheon, Korea which is occupied by vegetation fields, orchards and small barns. Accordingly, chemical fertilizers and manures are frequently applied on the land surface for agricultural purposes. Area of land use type - vegetation fields, orchards, and small barns - within the probabilistic capture zones, land slope, and elevation are used as explanatory variables. As dependent variable, nitrate concentrations observed at pumping wells are used. The proposed method gives better prediction of nitrate concentration than the general regression model using circular buffer zones does. Also, it is expected that the proposed method can be effectively used to relate the loading mass of fertilizer and its concentration in ground water at pumping wells and further to suggest an allowable loading mass of fertilizer for preservation of ground water quality under regulatory limits.

  14. Monitoring the performance of Aux. Feedwater Pump using Smart Sensing Model

    International Nuclear Information System (INIS)

    No, Young Gyu; Seong, Poong Hyun

    2015-01-01

    Many artificial intelligence (AI) techniques equipped with learning systems have recently been proposed to monitor sensors and components in NPPs. Therefore, the objective of this study is the development of an integrity evaluation method for safety critical components such as Aux. feedwater pump, high pressure safety injection (HPSI) pump, etc. using smart sensing models based on AI techniques. In this work, the smart sensing model is developed at first to predict the performance of Aux. feedwater pump by estimating flowrate using group method of data handing (GMDH) method. If the performance prediction is achieved by this feasibility study, the smart sensing model will be applied to development of the integrity evaluation method for safety critical components. Also, the proposed algorithm for the performance prediction is verified by comparison with the simulation data of the MARS code for station blackout (SBO) events. In this study, the smart sensing model for the prediction performance of Aux. feedwater pump has been developed. In order to develop the smart sensing model, the GMDH algorithm is employed. The GMDH algorithm is the way to find a function that can well express a dependent variable from independent variables. This method uses a data structure similar to that of multiple regression models. The proposed GMDH model can accurately predict the performance of Aux

  15. An improved turbulence model for separation flow in a centrifugal pump

    Directory of Open Access Journals (Sweden)

    Yun Ren

    2016-06-01

    Full Text Available For the stable and reliable operation of centrifugal pump, the transient flow must be studied and the separation region should be avoided. Three-dimensional, incompressible, steady, and transient flows in a centrifugal pump at specific speed within 74 were numerically studied using shear stress transport k-ω turbulence model, and an improved explicit algebraic Reynolds stress model–rotation-curvature turbulence model was proposed by considering the effects of rotation and curvature in the impeller passages in this work. Steady and transient computations were conducted to compare with the experiments. The comparison of pump hydraulic performance showed that the explicit algebraic Reynolds stress model–rotation-curvature turbulence model was better than the original model, especially between 0.6QBEP and 1.2QBEP; the improved model could enhance the head prediction of pump by about 1%–7% than that with the original model. Then, the visualization of the vortex evolution was observed to validate the unsteady simulations. Good agreement was investigated between calculations and visualizations. It is indicated that the explicit algebraic Reynolds stress model–rotation-curvature model can successfully capture the separation flow.

  16. Modeling of an Air Conditioning System with Geothermal Heat Pump for a Residential Building

    Directory of Open Access Journals (Sweden)

    Silvia Cocchi

    2013-01-01

    Full Text Available The need to address climate change caused by greenhouse gas emissions attaches great importance to research aimed at using renewable energy. Geothermal energy is an interesting alternative concerning the production of energy for air conditioning of buildings (heating and cooling, through the use of geothermal heat pumps. In this work a model has been developed in order to simulate an air conditioning system with geothermal heat pump. A ground source heat pump (GSHP uses the shallow ground as a source of heat, thus taking advantage of its seasonally moderate temperatures. GSHP must be coupled with geothermal exchangers. The model leads to design optimization of geothermal heat exchangers and to verify the operation of the geothermal plant.

  17. A real option-based simulation model to evaluate investments in pump storage plants

    International Nuclear Information System (INIS)

    Muche, Thomas

    2009-01-01

    Investments in pump storage plants are expected to grow especially due to their ability to store an excess of supply from wind power plants. In order to evaluate these investments correctly the peculiarities of pump storage plants and the characteristics of liberalized power markets have to be considered. The main characteristics of power markets are the strong power price volatility and the occurrence of prices spikes. In this article a valuation model is developed capturing these aspects using power price simulation, optimization of unit commitment and capital market theory. This valuation model is able to value a future price-based unit commitment planning that corresponds to future scope of actions also called real options. The resulting real option value for the pump storage plant is compared with the traditional net present value approach. Because this approach is not able to evaluate scope of actions correctly it results in strongly smaller investment values and forces wrong investment decisions.

  18. Modeling of a diode-pumped thin-disk cesium vapor laser

    Science.gov (United States)

    An, Guofei; Cai, He; Liu, Xiaoxu; Han, Juhong; Zhang, Wei; Wang, Hongyuan; Wang, You

    2018-03-01

    A diode pumped alkali laser (DPAL) provides a significant potential for construction of high-powered lasers. Until now, a series of models have been established to analyze the kinetic process and most of them are based on the end-pumped alkali laser system in which the vapor cell are usually cylindrical and cuboid. In this paper, a mathematic model is constructed to investigate the kinetic processes of a diode pumped thin-disk cesium vapor laser, in which the cesium vapor and the buffer gases are beforehand filled in a sealed glass cell with a thin-disk structure. We systemically study the influences of the cell temperature and cell thickness on the output features of a thin-disk DPAL. Further, we study the thin-disk DPAL with the W-shaped resonator and multiple-disk configuration. To the best of our knowledge, there have not been any similar reports so far.

  19. Modeling and Optimization of a CoolingTower-Assisted Heat Pump System

    Directory of Open Access Journals (Sweden)

    Xiaoqing Wei

    2017-05-01

    Full Text Available To minimize the total energy consumption of a cooling tower-assisted heat pump (CTAHP system in cooling mode, a model-based control strategy with hybrid optimization algorithm for the system is presented in this paper. An existing experimental device, which mainly contains a closed wet cooling tower with counter flow construction, a condenser water loop and a water-to-water heat pump unit, is selected as the study object. Theoretical and empirical models of the related components and their interactions are developed. The four variables, viz. desired cooling load, ambient wet-bulb temperature, temperature and flow rate of chilled water at the inlet of evaporator, are set to independent variables. The system power consumption can be minimized by optimizing input powers of cooling tower fan, spray water pump, condenser water pump and compressor. The optimal input power of spray water pump is determined experimentally. Implemented on MATLAB, a hybrid optimization algorithm, which combines the Limited memory Broyden-Fletcher-Goldfarb-Shanno (L-BFGS algorithm with the greedy diffusion search (GDS algorithm, is incorporated to solve the minimization problem of energy consumption and predict the system’s optimal set-points under quasi-steady-state conditions. The integrated simulation tool is validated against experimental data. The results obtained demonstrate the proposed operation strategy is reliable, and can save energy by 20.8% as compared to an uncontrolled system under certain testing conditions.

  20. Reaction kinetics of oxygen on single-phase alloys, oxidation of nickel and niobium alloys

    International Nuclear Information System (INIS)

    Lalauze, Rene

    1973-01-01

    This research thesis first addresses the reaction kinetics of oxygen on alloys. It presents some generalities on heterogeneous reactions (conventional theory, theory of jumps), discusses the core reaction (with the influence of pressure), discusses the influence of metal self-diffusion on metal oxidation kinetics (equilibrium conditions at the interface, hybrid diffusion regime), reports the application of the hybrid diffusion model to the study of selective oxidation of alloys (Wagner model, hybrid diffusion model) and the study of the oxidation kinetics of an alloy forming a solid solution of two oxides. The second part reports the investigation of the oxidation of single phase nickel and niobium alloys (phase α, β and γ)

  1. Investigation of effect of single phase electrical faults at LOFT

    International Nuclear Information System (INIS)

    Yeates, J.A.

    1978-01-01

    This LTR presents the general basic engineering facts related to an open phase fault in a three phase power system commonly referred to as a single phase condition. It describes the probable results to electrical motors and describes the LOFT system design factors which minimize the likelihood of such a fault occurring at LOFT. It recognizes that the hazard of such a fault is a realistic threat and notes the types of relays designed to provide protection. Recommendations are made to perform a detailed engineering study to determine the most advantageous protective relay design, and to implement such a design by installation of the necessary devices and controls

  2. Improved PLL structures for single-phase grid inverters

    DEFF Research Database (Denmark)

    Ciobotaru, Mihai; Teodorescu, Remus; Blaabjerg, Frede

    2005-01-01

    of the reference signals. This paper presents two improved phase-locked-loop (PLL) methods for single-phase grid connected systems. The investigated PLL methods are based on a transport delay method and an inverse Park transformation method. The improvements in the case of using the delay-based PLL are: non......-frequency dependent and better filtering of the harmonics. For the other investigated PLL method based on inverse Park transformation the improvement consists of better filtering of the harmonics. Experimental results validate the effectiveness of the two proposed methods....

  3. Dynamics Assessment of Advanced Single-Phase PLL Structures

    DEFF Research Database (Denmark)

    Golestan, Saeed; Monfarad, Mohammad; Freijedo, Francisco D.

    2013-01-01

    , and desired performance under frequency-varying and harmonically distorted grid conditions. Despite the wide acceptance and use of these two advanced PLLs, no comprehensive design guidelines to fine-tune their parameters have been reported yet. Through a detailed mathematical analysis it is shown......Recently, several advanced phase locked loop (PLL) techniques have been proposed for single-phase applications. Among these, the Park-PLL, and the second order generalized integrator (SOGI) based PLL are very attractive, owing to their simple digital implementation, low computational burden...

  4. Solution Concept of Modular Single Phase Active Power Filters

    Directory of Open Access Journals (Sweden)

    Marek Roch

    2006-01-01

    Full Text Available This paper investigates a modular or a decentralised single-phase active power filter control strategy. It is based on the evaluation of the harmonic reference load currents for the active power filter blocks operating under specific harmonic frequencies. The underlying principle of the modular active power filter is explained and it is shown how the required reference harmonic currents can be evaluated. Simulation results demonstrated the improvement in the dynamic performance of the modular active power filter presented here in comparison with the conventional type.

  5. A Transformer-less Single Phase Inverter For photovoltaic Systems

    DEFF Research Database (Denmark)

    Mostaan, Ali; Alizadeh, Ebrahim; Qu, Ying

    2017-01-01

    A single phase transformer-less inverter is introduced in this paper. The negative polarities of the input voltage and output terminal have common ground. Therefore, the leakage current problem that is common in PV systems is eliminated naturally. In addition, the proposed inverter has fewer...... components compared with its counterparts and only one switch conducts during the active states which enhance the inverter efficiency. The proposed inverter is analyzed in details and compared with some existing topologies. The performance of the proposed inverter is validated using the simulation results....

  6. Hypothesized diprotomeric enzyme complex supported by stochastic modelling of palytoxin-induced Na/K pump channels.

    Science.gov (United States)

    Vilallonga, Gabriel D; de Almeida, Antônio-Carlos G; Ribeiro, Kelison T; Campos, Sergio V A; Rodrigues, Antônio M

    2018-03-01

    The sodium-potassium pump (Na + /K + pump) is crucial for cell physiology. Despite great advances in the understanding of this ionic pumping system, its mechanism is not completely understood. We propose the use of a statistical model checker to investigate palytoxin (PTX)-induced Na + /K + pump channels. We modelled a system of reactions representing transitions between the conformational substates of the channel with parameters, concentrations of the substates and reaction rates extracted from simulations reported in the literature, based on electrophysiological recordings in a whole-cell configuration. The model was implemented using the UPPAAL-SMC platform. Comparing simulations and probabilistic queries from stochastic system semantics with experimental data, it was possible to propose additional reactions to reproduce the single-channel dynamic. The probabilistic analyses and simulations suggest that the PTX-induced Na + /K + pump channel functions as a diprotomeric complex in which protein-protein interactions increase the affinity of the Na + /K + pump for PTX.

  7. A new model of centrifugal blood pump for cardiopulmonary bypass: design improvement, performance, and hemolysis tests.

    Science.gov (United States)

    Leme, Juliana; Fonseca, Jeison; Bock, Eduardo; da Silva, Cibele; da Silva, Bruno Utiyama; Dos Santos, Alex Eugênio; Dinkhuysen, Jarbas; Andrade, Aron; Biscegli, José F

    2011-05-01

    A new model of blood pump for cardiopulmonary bypass (CPB) application has been developed and evaluated in our laboratories. Inside the pump housing is a spiral impeller that is conically shaped and has threads on its surface. Worm gears provide an axial motion of the blood column. Rotational motion of the conical shape generates a centrifugal pumping effect and improves pumping performance. One annular magnet with six poles is inside the impeller, providing magnetic coupling to a brushless direct current motor. In order to study the pumping performance, a mock loop system was assembled. Mock loop was composed of Tygon tubes (Saint-Gobain Corporation, Courbevoie, France), oxygenator, digital flowmeter, pressure monitor, electronic driver, and adjustable clamp for flow control. Experiments were performed on six prototypes with small differences in their design. Each prototype was tested and flow and pressure data were obtained for rotational speed of 1000, 1500, 2000, 2500, and 3000 rpm. Hemolysis was studied using pumps with different internal gap sizes (1.35, 1.45, 1.55, and 1.7 mm). Hemolysis tests simulated CPB application with flow rate of 5 L/min against total pressure head of 350 mm Hg. The results from six prototypes were satisfactory, compared to the results from the literature. However, prototype #6 showed the best results. Best hemolysis results were observed with a gap of 1.45 mm, and showed a normalized index of hemolysis of 0.013 g/100 L. When combined, axial and centrifugal pumping principles produce better hydrodynamic performance without increasing hemolysis. © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  8. Performance and Economic Modeling of Horizontally Drilled Ground-Source Heat Pumps in Select California Climates

    Science.gov (United States)

    Wiryadinata, Steven

    Service life modeling was performed to gage the viability of unitary 3.5 kWt, ground-source terminal heat pumps (GTHP) employing horizontal directionally drilled geothermal heat exchangers (GHX) over air-source terminal heat pumps (PTHP) in hotels and motels and residential apartment building sectors in California's coastal and inland climates. Results suggest the GTHP can reduce hourly peak demand for the utility by 7%-25% compared to PTHP, depending on the climate and building type. The annual energy savings, which range from -1% to 5%, are highly dependent on the GTHP pump energy use relative to the energy savings attributed to the difference in ground and air temperatures (DeltaT). In mild climates with small ?T, the pump energy use may overcome any advantage to utilizing a GHX. The majority of total levelized cost savings - ranging from 0.18/ft2 to 0.3/ft 2 - are due to reduced maintenance and lifetime capital cost normally associated with geothermal heat pump systems. Without these reductions (not validated for the GTHP system studied), the GTHP technology does not appear to offer significant advantages over PTHP in the climate zones studied here. The GTHP levelized cost was most sensitive to variations in installed cost and in some cases, energy use (influenced by climate zone choice), which together highlights the importance of climate selection for installation, and the need for larger market penetration of ground-source systems in order to bring down installed costs as the technology matures.

  9. Dynamic Modeling, Control, and Analysis of a Solar Water Pumping System for Libya

    Directory of Open Access Journals (Sweden)

    Muamer M. Shebani

    2017-01-01

    Full Text Available In recent years, one of the suitable solar photovoltaic (PV applications is a water pumping system. The simplest solar PV pumping system consists of PV array, DC-DC converter, DC motor, and water pump. In this paper, water pumping system sizing for Libya is evaluated based on a daily demand using HOMER software, and dynamic modeling of a solar PV water pumping system using a Permanent Magnet DC (PMDC motor is presented in Matlab/Simulink environment. The system performance with maximum power point tracking (MPPT based on Fractional Open Circuit Voltage (FOCV is evaluated with and without a battery storage system. In some applications, a rated voltage is needed to connect a PMDC motor to a PV array through a DC-DC converter and in other applications the input voltage can vary. The evaluation of the system is based on the performance during a change in solar irradiation. Using Matlab/Simulink, simulation results are assessed to see the efficiency of the system when it is operating at a specific speed or at the MPPT. The results show that an improvement in the system efficiency can be achieved when the PMDC motor is running at a specific speed rather than at the peak PV power point.

  10. Rate equation modelling of the optically pumped spin-exchange source

    International Nuclear Information System (INIS)

    Stenger, J.; Rith, K.

    1995-01-01

    Sources for spin polarized hydrogen or deuterium, polarized via spin-exchange of a laser optically pumped alkali metal, can be modelled by rate equations. The rate equations for this type of source, operated either with hydrogen or deuterium, are given explicitly with the intention of providing a useful tool for further source optimization and understanding. Laser optical pumping of alkali metal, spin-exchange collisions of hydrogen or deuterium atoms with each other and with alkali metal atoms are included, as well as depolarization due to flow and wall collisions. (orig.)

  11. Simplified model of a volumetric direct nuclear pumped He-3-Ar laser

    Science.gov (United States)

    Harries, W. L.; Wilson, J. W.

    1979-01-01

    A physical model for the volumetric nuclear pumped He-3-Ar laser is described and the source terms arising from the He-3(n, p)H-3 reaction as well as the rate equations are given. Steady state solutions are derived for the densities of the species vs the fraction of argon. The dominant pumping mechanism is found to be collisional radiative recombination of the argon atomic ions and subsequent cascading into the upper laser level. The reactions following recombination are described and an expression is derived for the difference in densities of the argon 3d and 4p levels. Comparison with experiments shows good agreement.

  12. Hemodynamic support with the pulsatile catheter pump in a sheep model of acute heart failure

    NARCIS (Netherlands)

    Li, Zhicheng; Gu, Y. John; Ye, Qing; Cheng, Shaofei; Wang, Weijun; Tang, Min; Zhao, Xiaogang; Rakhorst, Gerhard; Chen, Changzhi

    2006-01-01

    This study was aimed to mimic clinical heart failure (HF) conditions and to assess the effect of pulsatilecatheter (PUCA) pump support on hemodynamics and tissue perfusion in a sheep model of acute HF. In 14 sheep, HF was induced by partial occluding the middle left circumflex coronary artery

  13. Pumps modelling of a sodium fast reactor design and analysis of hydrodynamic behavior

    Directory of Open Access Journals (Sweden)

    Ordóñez Ródenas José

    2016-01-01

    Full Text Available One of the goals of Generation IV reactors is to increase safety from those of previous generations. Different research platforms have been identified the need to improve the reliability of the simulation tools to ensure the capability of the plant to accommodate the design basis transients established in preliminary safety studies. The paper describes the modelling of primary pumps in advanced sodium cooled reactors using the TRACE code. Following the implementation of the models, the results obtained in the analysis of different design basis transients are compared with the simplifying approximations used in reference models. The paper shows the process to obtain a consistent pump model of the ESFR (European Sodium Fast Reactor design and the analysis of loss of flow transients triggered by pumps coast–down analyzing the thermal hydraulic neutronic coupled system response. A sensitivity analysis of the system pressure drops effect and the other relevant parameters that influence the natural convection after the pumps coast–down is also included.

  14. Model based fault diagnosis in a centrifugal pump application using structural analysis

    DEFF Research Database (Denmark)

    Kallesøe, C. S.; Izadi-Zamanabadi, Roozbeh; Rasmussen, Henrik

    2004-01-01

    A model based approach for fault detection and isolation in a centrifugal pump is proposed in this paper. The fault detection algorithm is derived using a combination of structural analysis, Analytical Redundant Relations (ARR) and observer designs. Structural considerations on the system are used...

  15. Model Based Fault Diagnosis in a Centrifugal Pump Application using Structural Analysis

    DEFF Research Database (Denmark)

    Kallesøe, C. S.; Izadi-Zamanabadi, Roozbeh; Rasmussen, Henrik

    2004-01-01

    A model based approach for fault detection and isolation in a centrifugal pump is proposed in this paper. The fault detection algorithm is derived using a combination of structural analysis, Analytical Redundant Relations (ARR) and observer designs. Structural considerations on the system are used...

  16. Improved Modeling of Residential Air Conditioners and Heat Pumps for Energy Calculations

    Energy Technology Data Exchange (ETDEWEB)

    Cutler, D. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Winkler, J. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Kruis, N. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Christensen, C. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Brandemuehl, M. [Univ. of Colorado, Boulder, CO (United States)

    2013-01-01

    This report presents improved air conditioner and heat pump modeling methods in the context of whole-building simulation tools, with the goal of enabling more accurate evaluation of cost-effective equipment upgrade opportunities and efficiency improvements in residential buildings.

  17. Reducing Electromagnetic Interference in a Grid Tied Single Phase Power Inverter

    Science.gov (United States)

    2016-09-01

    ELECTROMAGNETIC INTERFERENCE IN A GRID TIED SINGLE PHASE POWER INVERTER by Jason Hassan Valiani September 2016 Thesis Advisor: Giovanna Oriti...3. REPORT TYPE AND DATES COVERED Master’s thesis 4. TITLE AND SUBTITLE REDUCING ELECTROMAGNETIC INTERFERENCE IN A GRID TIED SINGLE PHASE POWER...The addition of a passive filter proved to minimize the conducted EMI for a single -phase grid-tied inverter. 14. SUBJECT TERMS single -phase

  18. Characterization of the cardiac Na+/K+ pump by development of a comprehensive and mechanistic model.

    Science.gov (United States)

    Oka, Chiaki; Cha, Chae Young; Noma, Akinori

    2010-07-07

    A large amount of experimental data on the characteristics of the cardiac Na(+)/K(+) pump have been accumulated, but it remains difficult to predict the quantitative contribution of the pump in an intact cell because most measurements have been made under non-physiological conditions. To extrapolate the experimental findings to intact cells, we have developed a comprehensive Na(+)/K(+) pump model based on the thermodynamic framework (Smith and Crampin, 2004) of the Post-Albers reaction cycle combined with access channel mechanisms. The new model explains a variety of experimental results for the Na(+)/K(+) pump current (I(NaK)), including the dependency on the concentrations of Na(+) and K(+), the membrane potential and the free energy of ATP hydrolysis. The model demonstrates that both the apparent affinity and the slope of the substrate-I(NaK) relationship measured experimentally are affected by the composition of ions in the extra- and intracellular solutions, indirectly through alteration in the probability distribution of individual enzyme intermediates. By considering the voltage dependence in the Na(+)- and K(+)-binding steps, the experimental voltage-I(NaK) relationship could be reconstructed with application of experimental ionic compositions in the model, and the view of voltage-dependent K(+) binding was supported. Re-evaluation of charge movements accompanying Na(+) and K(+) translocations gave a reasonable number for the site density of the Na(+)/K(+) pump on the membrane. The new model is relevant for simulation of cellular functions under various interventions, such as depression of energy metabolism. (c) 2010 Elsevier Ltd. All rights reserved.

  19. Thermodynamics of information processing based on enzyme kinetics: An exactly solvable model of an information pump

    Science.gov (United States)

    Cao, Yuansheng; Gong, Zongping; Quan, H. T.

    2015-06-01

    Motivated by the recent proposed models of the information engine [Proc. Natl. Acad. Sci. USA 109, 11641 (2012), 10.1073/pnas.1204263109] and the information refrigerator [Phys. Rev. Lett. 111, 030602 (2013), 10.1103/PhysRevLett.111.030602], we propose a minimal model of the information pump and the information eraser based on enzyme kinetics. This device can either pump molecules against the chemical potential gradient by consuming the information to be encoded in the bit stream or (partially) erase the information initially encoded in the bit stream by consuming the Gibbs free energy. The dynamics of this model is solved exactly, and the "phase diagram" of the operation regimes is determined. The efficiency and the power of the information machine is analyzed. The validity of the second law of thermodynamics within our model is clarified. Our model offers a simple paradigm for the investigating of the thermodynamics of information processing involving the chemical potential in small systems.

  20. Mathematical Model Defining Volumetric Losses of Hydraulic Oil Compression in a Variable Capacity Displacement Pump

    Directory of Open Access Journals (Sweden)

    Paszota Zygmunt

    2015-01-01

    Full Text Available The objective of the work is to develop the capability of evaluating the volumetric losses of hydraulic oil compression in the working chambers of high pressure variable capacity displacement pump. Volumetric losses of oil compression must be determined as functions of the same parameters, which the volumetric losses due to leakage, resulting from the quality of design solution of the pump, are evaluated as dependent on and also as function of the oil aeration coefficient Ɛ. A mathematical model has been developed describing the hydraulic oil compressibility coefficient klc|Δppi;Ɛ;v as a relation to the ratio ΔpPi/pn of indicated increase ΔpPi of pressure in the working chambers and the nominal pressure pn, to the pump capacity coefficient bP, to the oil aeration coefficient  and to the ratio v/vnof oil viscosity v and reference viscosity vn. A mathematical model is presented of volumetric losses qpvc|ΔpPi;bp;;vof hydraulic oil compression in the pump working chambers in the form allowing to use it in the model of power of losses and energy efficiency

  1. Modeling the Performance of Water-Zeolite 13X Adsorption Heat Pump

    Science.gov (United States)

    Kowalska, Kinga; Ambrożek, Bogdan

    2017-12-01

    The dynamic performance of cylindrical double-tube adsorption heat pump is numerically analysed using a non-equilibrium model, which takes into account both heat and mass transfer processes. The model includes conservation equations for: heat transfer in heating/cooling fluids, heat transfer in the metal tube, and heat and mass transfer in the adsorbent. The mathematical model is numerically solved using the method of lines. Numerical simulations are performed for the system water-zeolite 13X, chosen as the working pair. The effect of the evaporator and condenser temperatures on the adsorption and desorption kinetics is examined. The results of the numerical investigation show that both of these parameters have a significant effect on the adsorption heat pump performance. Based on computer simulation results, the values of the coefficients of performance for heating and cooling are calculated. The results show that adsorption heat pumps have relatively low efficiency compared to other heat pumps. The value of the coefficient of performance for heating is higher than for cooling

  2. COMMIX-1AR/P: A three-dimensional transient single-phase computer program for thermal hydraulic analysis of single and multicomponent systems. Volume 2, User`s guide

    Energy Technology Data Exchange (ETDEWEB)

    Garner, P.L.; Blomquist, R.N.; Gelbard, E.M.

    1992-09-01

    The COMMIX-1AR/P computer program is designed for analyzing the steady-state and transient aspects of single-phase fluid flow and heat transfer in three spatial dimensions. This version is an extension of the modeling in COMMIX-1A to include multiple fluids in physically separate regions of the computational domain, modeling descriptions for pumps, radiation heat transfer between surfaces of the solids which are embedded in or surround the fluid, a k-{var_epsilon} model for fluid turbulence, and improved numerical techniques. The porous-medium formulation in COMMIX allows the program to be applied to a wide range of problems involving both simple and complex geometrical arrangements. The input preparation and execution procedures are presented for the COMMIX-1AR/P program and several postprocessor programs which produce graphical displays of the calculated results.

  3. Model Predictive Control Algorithms for Pen and Pump Insulin Administration

    DEFF Research Database (Denmark)

    Boiroux, Dimitri

    parameters are personalized using a priori available patient information. We consider an autoregressive integrated moving average with exogenous input (ARIMAX) model. Wesummarize and the results of the overnight clinical studies conducted at Hvidovre Hospital. Based on these results, we propose improvements...... ARMAX model in which we estimate the parameters of the stochastic part using a Recursive Least Square (RLS) method. We test the controller in a virtual clinic of 100 patients. This virtual clinic is based on the Hovorka model. We consider the case where only half of the bolus is administrated...

  4. Heat Pump Water Heater Modeling in EnergyPlus (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, E.; Christensen, C.

    2012-03-01

    This presentation summarizes NREL's development of a HPWH model for use in hourly building energy simulation programs, such as BEopt; this presentation was given at the Building America Stakeholder meeting on March 1, 2012, in Austin, Texas.

  5. Heat Pump Water Heating Modeling in EnergyPlus

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric [National Renewable Energy Lab. (NREL), Golden, CO (United States); Christensen, Craig [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2012-03-01

    This presentation summarizes NREL's development of a HPWH model for use in hourly building energy simulation programs, such as BEopt; this presentation was given at the Building America Stakeholder meeting on March 1, 2012, in Austin, Texas.

  6. Energy Efficiency Modelling of Residential Air Source Heat Pump Water Heater

    Directory of Open Access Journals (Sweden)

    Cong Toan Tran

    2016-03-01

    Full Text Available The heat pump water heater is one of the most energy efficient technologies for heating water for household use. The present work proposes a simplified model of coefficient of performance and examines its predictive capability. The model is based on polynomial functions where the variables are temperatures and the coefficients are derived from the Australian standard test data, using regression technics. The model enables to estimate the coefficient of performance of the same heat pump water heater under other test standards (i.e. US, Japanese, European and Korean standards. The resulting estimations over a heat-up phase and a full test cycle including a draw off pattern are in close agreement with the measured data. Thus the model allows manufacturers to avoid the need to carry out physical tests for some standards and to reduce product cost. The limitations of the methodology proposed are also discussed.

  7. Control of Single-Stage Single-Phase PV inverter

    DEFF Research Database (Denmark)

    Ciobotaru, Mihai; Teodorescu, Remus; Blaabjerg, Frede

    2005-01-01

    In this paper the issue of control strategies for single-stage photovoltaic (PV) inverter is addressed. Two different current controllers have been implemented and an experimental comparison between them has been made. A complete control structure for the single-phase PV system is also presented......-forward; - and the grid current controller implemented in two different ways, using the classical proportional integral (PI) and the novel proportional resonant (PR) controllers. The control strategy was tested experimentally on 1.5 kW PV inverter........ The main elements of the PV control structure are: - a maximum power point tracker (MPPT) algorithm using the incremental conductance method; - a synchronization method using the phase-locked-loop (PLL), based on delay; - the input power control using the dc voltage controller and power feed...

  8. Analysis of vorticity dynamics for hump characteristics of a pump turbine model

    International Nuclear Information System (INIS)

    Li, Deyou; Gong, Ruzhi; Wang, Hongjie; Han, Lei; Wei, Xianzhu; Qin, Daqing

    2016-01-01

    Conventional parameters based on CFD methodology for the investigation on hump characteristics of a pump turbine cannot reflect the dynamic interaction mechanism between the runner and the fluid. This research presents a dynamic interaction mechanism of a pump turbine operating in the hump region. First, vorticity dynamic parameters were obtained based on the theory of vorticity dynamics. Second, 3-D unsteady flow simulations were performed in a full pump turbine model using the SST k-ω turbulence model, and numerical results have a good agreement with the experiments. Then, analysis was carried out to determine the relation between the vorticity dynamic parameters and hump characteristics. The results indicate that the theory of vorticity dynamics has an advantage in evaluating the dynamic performance of a pump turbine. The energy transfer between the runner and the fluid is through vorticity dynamic parameters-pressure and friction terms, in which the pressure term accounts for the most. Furthermore, vortex generation mainly results from the skin friction. Combining vorticity dynamic analysis with the method of Q-criterion indicates that hump characteristics are related to the reduction of the surface normal pressure work and vortex motion on the suction surfaces close to the leading edges in the runner, and the increase of skin friction work in the stay-guide vanes

  9. Frequency Adaptive Repetitive Control of Grid-Tied Single-Phase PV Inverters

    DEFF Research Database (Denmark)

    Zhou, Keliang; Yang, Yongheng; Blaabjerg, Frede

    2015-01-01

    . This paper thus explores a frequency adaptive repetitive control strategy for grid converters, which employs fractional delay filters in order to adapt to the change of the grid frequency. Case studies with experimental results of a single-phase grid-connected PV inverter system are provided to verify......The internal model principle based Repetitive Control (RC) offers an accurate control strategy for grid-tied power converters to feed sinusoidal current into the grid. However, in the presence of grid frequency variations, the conventional RC fails to produce high quality feeding current...... the proposed controller....

  10. Design and analysis of sensorless torque optimization for single phase induction motors

    International Nuclear Information System (INIS)

    Vaez-Zadeh, S.; Payman, A.

    2006-01-01

    Single phase induction motors are traditionally used in constant speed applications and suffer from unsymmetrical performance. A reliable speed signal can improve their performance and extend their applications as variable speed drives. In this paper, a speed estimation method for these motors is proposed based on a machine model in the stator flux reference frame. The method is examined in a sensorless torque optimization system over a wide operating range. Extensive simulation results prove the validity of the proposed method. Also, the motor performance under the torque optimization system is analyzed

  11. Indirect Control of a low power Single-Phase Active Power Filter

    Directory of Open Access Journals (Sweden)

    SILVIU EPURE

    2010-12-01

    Full Text Available This paper deals with a low power, single phase active filter used to compensate nonlinear loads. The filter uses the indirect control method and it is based on a particular connection between filter, polluting load and grid to avoid timeconsuming mathematic operations or signal processing computations and assures good rejection of harmonic currents injected by the nonlinear load into the grid. A scale model was first simulated in Simulink and then physically implemented. The paper presents simulation and experimental results, and highlight problems encountered during experiments.

  12. Benchmarking of small-signal dynamics of single-phase PLLs

    DEFF Research Database (Denmark)

    Zhang, Chong; Wang, Xiongfei; Blaabjerg, Frede

    2015-01-01

    Phase-looked Loop (PLL) is a critical component for the control and grid synchronization of grid-connected power converters. This paper presents a benchmarking study on the small-signal dynamics of three commonly used PLLs for single-phase converters, including enhanced PLL, second......-order generalized integrator based PLL, and the inverse-PLL. First, a unified small-signal model of those PLLs is established for comparing their dynamics. Then, a systematic design guideline for parameters tuning of the PLLs is formulated. To confirm the validity of theoretical analysis, nonlinear time...

  13. Single Phase Current-Source Active Rectifier for Traction: Control System Design and Practical Problems

    Directory of Open Access Journals (Sweden)

    Jan Michalik

    2006-01-01

    Full Text Available This research has been motivated by industrial demand for single phase current-source active rectifier dedicated for reconstruction of older types of dc machine locomotives. This paper presents converters control structure design and simulations. The proposed converter control is based on the mathematical model and due to possible interaction with railway signaling and required low switching frequency employs synchronous PWM. The simulation results are verified by experimental tests performed on designed laboratory prototype of power of 7kVA

  14. Operation and maintenance manual: ELECTROMAGNETIC PUMP, Model 18 EPA 38A01-14,500 GPM. [LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    1976-12-31

    This manual is a serialized document issued by General Electric, Fast Breeder Reactor Department, EM Pump Engineering. The manual contains information and requirements relevant to the installation, operation, and maintenance of General Electric ELECTROMAGNETIC PUMP Model 18EPA28A01 at the Liquid Metal Engineering Center, Santa Susana, California.

  15. Modeling of neutral transport and impurity generation in the Tore Supra pump limiter

    International Nuclear Information System (INIS)

    Klepper, C.C.; Owen, L.W.; Mioduszewski, P.K.; Grosman, A.

    1989-01-01

    A system of modular pump limiters is employed in Tore Supra for particle control. It includes one large outboard module which is instrumented with an optical multi-channel analyzer viewing the neutralizer plate, in addition to pressure, temperature and particle diagnostics. The transport of neutrals in both the particle scoop mode and in the pump limiter mode with active pumping is modeled with the DEGAS code. Equilibrium neutral pressure and density, H α -intensity at the neutralizer plate, and particle back-flow into the scrape-off layer are calculated for typical projected plasma edge conditions. Effects on neutral particle transport of varying the length of the ''shelf'' separating the throat region from the pumping chamber are investigated. The generation and transport of carbon impurities arising from ion impact sputtering at the neutralizer plate are estimated. The short mean-free-path for ionization of sputtered carbon atoms suggests the possibility of spectroscopically measuring the effects of poloidal flux variations arising from shadowing of the modular limiter system. (orig.)

  16. Application of the hydrodynamic predictive modeling on the example of the pumping station 'Bezdan 1'

    Directory of Open Access Journals (Sweden)

    Polomčić Dušan M.

    2014-01-01

    Full Text Available In the area of Bezdan, the construction of a new pumping station, p.s. 'Bezdan 1', on the location of the existing and nonfunctional pumping station 'Bezdan I', is envisaged. Given the position of the future pump station, a problem of digging the foundation pits in terms of protection from high groundwater levels, was noticed. This paper aims to analyze the possibilities for lowering the groundwater levels below the projected elevation, which will enable unobstructed work on the pumping station. By using the hydrodynamic analysis and its most complex and most applicable methods of three-dimensional hydrodynamic modeling of aquifer regime, based on the numerical method of finite differences, the system of protection and variations of the protection solutions from groundwater at the research location of the future p.s. 'Bezdan 1' was defined. Three variants of solution were given, and characteristics of the system of protection from groundwater were defined for each, the optimal number of drainage wells in the system and their spatial distribution and the time required for maximal effects of the lowering of the groundwater levels below the elevation of the excavation facilities of CS 'Bezdan 1'. Presented paper provides the basis for some of the methods of multicriteria optimization and the selection of the optimal variant of the system of protection from groundwater's, considering, in this way, the weight of various factors that influence the choice of the variant, such as technical, economic, environmental and safety factors.

  17. Modeling of ITER related vacuum gas pumping distribution systems

    Energy Technology Data Exchange (ETDEWEB)

    Misdanitis, Serafeim [University of Thessaly, Department of Mechanical Engineering, Pedion Areos, 38334 Volos (Greece); Association EURATOM - Hellenic Republic (Greece); Valougeorgis, Dimitris, E-mail: diva@mie.uth.gr [University of Thessaly, Department of Mechanical Engineering, Pedion Areos, 38334 Volos (Greece); Association EURATOM - Hellenic Republic (Greece)

    2013-10-15

    Highlights: • An algorithm to simulate vacuum gas flows through pipe networks consisting of long channels and channels of moderate length has been developed. • Analysis and results are based on kinetic theory as described by the BGK kinetic model equation. • The algorithm is capable of computing the mass flow rates (or the conductance) through the pipes and the pressure at the nodes of the network. • Since a kinetic approach is implemented, the algorithm is valid in the whole range of the Knudsen number. • The developed algorithm will be useful for simulating the vacuum distribution systems of ITER and future fusion reactors. -- Abstract: A novel algorithm recently developed to solve steady-state isothermal vacuum gas dynamics flows through pipe networks consisting of long tubes is extended to include, in addition to long channels, channels of moderate length 10 < L/D < 50. This is achieved by implementing the so-called end effect treatment/correction. Analysis and results are based on kinetic theory as described by the Boltzmann equation or associated reliable kinetic model equations. For a pipe network of known geometry the algorithm is capable of computing the mass flow rates (or the conductance) through the pipes as well as the pressure heads at the nodes of the network. The feasibility of the approach is demonstrated by simulating two ITER related vacuum distribution systems, one in the viscous regime and a second one in a wide range of Knudsen numbers. Since a kinetic approach is implemented, the algorithm is valid and the results are accurate in the whole range of the Knudsen number, while the involved computational effort remains small.

  18. Numerical investigation of refrigeration machine compressor operation considering single-phase electric motor dynamic characteristics

    Science.gov (United States)

    Baidak, Y.; Smyk, V.

    2017-08-01

    Using as the base the differential equations system which was presented in relative units for generalized electric motor of hermetic refrigeration compressor, mathematical model of the software for dynamic performance calculation of refrigeration machine compressors drive low-power asynchronous motors was developed. Performed on its ground calculations of the basic model of two-phase electric motor drive of hermetic compressor and the proposed newly developed model of the motor with single-phase stator winding, which is an alternative to the industrial motor winding, have confirmed the benefits of the motor with innovative stator winding over the base engine. Given calculations of the dynamic characteristics of compressor drive motor have permitted to determine the value of electromagnetic torque swinging for coordinating compressor and motor mechanical characteristics, and for taking them into consideration in choosing compressor elements construction materials. Developed and used in the process of investigation of refrigeration compressor drive asynchronous single-phase motor mathematical and software can be considered as an element of computer-aided design system for design of the aggregate of refrigeration compression unit refrigerating machine.

  19. Validation of CATHENA MOD-3.5/Rev0 for single-phase water hammer

    International Nuclear Information System (INIS)

    Beuthe, T.G.

    2000-01-01

    This paper describes work performed to validate the system thermalhydraulics code CATHENA MOD-3.5c/Rev0 for single-phase water hammer. Simulations were performed and are compared quantitatively against numerical tests and experimental results from the Seven Sisters Water Hammer Facility to demonstrate CATHENA can predict the creation and propagation of pressure waves when valves are opened and closed. Simulations were also performed to show CATHENA can model the behaviour of reflected and transmitted pressure waves at area changes, dead ends, tanks, boundary conditions, and orifices in simple and more complex piping systems. The CATHENA results are shown to calculate pressure and wave propagation speeds to within 0.2% and 0.5% respectively for numerical tests and within 3.3% and 5% for experimental results respectively. These results are used to help validate CATHENA for use in single-phase water hammer analysis. They also provide assurance that the fundamental parameters needed to successfully model more complex forms of water hammer are accounted for in the MOD-3.5c/Rev0 version of CATHENA, and represent the first step in the process to validate the code for use in modelling two-phase water hammer and condensation-induced water hammer. (author)

  20. Modeling Optimal Scheduling for Pumping System to Minimize Operation Cost and Enhance Operation Reliability

    Directory of Open Access Journals (Sweden)

    Yin Luo

    2012-01-01

    Full Text Available Traditional pump scheduling models neglect the operation reliability which directly relates with the unscheduled maintenance cost and the wear cost during the operation. Just for this, based on the assumption that the vibration directly relates with the operation reliability and the degree of wear, it could express the operation reliability as the normalization of the vibration level. The characteristic of the vibration with the operation point was studied, it could be concluded that idealized flow versus vibration plot should be a distinct bathtub shape. There is a narrow sweet spot (80 to 100 percent BEP to obtain low vibration levels in this shape, and the vibration also follows similar law with the square of the rotation speed without resonance phenomena. Then, the operation reliability could be modeled as the function of the capacity and rotation speed of the pump and add this function to the traditional model to form the new. And contrast with the tradition method, the result shown that the new model could fix the result produced by the traditional, make the pump operate in low vibration, then the operation reliability could increase and the maintenance cost could decrease.

  1. Model for Sucker-Rod Pumping Unit Operating Modes Analysis Based on SimMechanics Library

    Science.gov (United States)

    Zyuzev, A. M.; Bubnov, M. V.

    2018-01-01

    The article provides basic information about the process of a sucker-rod pumping unit (SRPU) model developing by means of SimMechanics library in the MATLAB Simulink environment. The model is designed for the development of a pump productivity optimal management algorithms, sensorless diagnostics of the plunger pump and pumpjack, acquisition of the dynamometer card and determination of a dynamic fluid level in the well, normalization of the faulty unit operation before troubleshooting is performed by staff as well as equilibrium ratio determining by energy indicators and outputting of manual balancing recommendations to achieve optimal power consumption efficiency. Particular attention is given to the application of various blocks from SimMechanics library to take into account the pumpjack construction principal characteristic and to obtain an adequate model. The article explains in depth the developed tools features for collecting and analysis of simulated mechanism data. The conclusions were drawn about practical implementation possibility of the SRPU modelling results and areas for further development of investigation.

  2. Dynamic Modeling of Adjustable-Speed Pumped Storage Hydropower Plant: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Muljadi, E.; Singh, M.; Gevorgian, V.; Mohanpurkar, M.; Havsapian, R.; Koritarov, V.

    2015-04-06

    Hydropower is the largest producer of renewable energy in the U.S. More than 60% of the total renewable generation comes from hydropower. There is also approximately 22 GW of pumped storage hydropower (PSH). Conventional PSH uses a synchronous generator, and thus the rotational speed is constant at synchronous speed. This work details a hydrodynamic model and generator/power converter dynamic model. The optimization of the hydrodynamic model is executed by the hydro-turbine controller, and the electrical output real/reactive power is controlled by the power converter. All essential controllers to perform grid-interface functions and provide ancillary services are included in the model.

  3. Frequency-domain modelling of gain in pump-probe experiment by an inhomogeneous medium

    Science.gov (United States)

    Kim, Minkyung; Oh, Sang Soon; Hess, Ortwin; Rho, Junsuk

    2018-02-01

    Introduction of a gain medium in lossy plasmonic metamaterials reduces and compensates losses or even amplifies an incident light often with nonlinear optical effect. Here, optical gain in a pump-probe experimental setup is effectively calculated in the frequency-domain by approximating a gain material as an inhomogeneous medium. Spatially varying local field amplitudes of the pump and probe beams are included in the model to reproduce the inhomogeneous gain effect, in which population inversion occurs most strongly near the surface and decays along the propagation direction. We demonstrate that transmission spectra calculated by this method agree well with finite-difference time-domain simulation results. This simplified approach of gain modelling offers an easy and reliable way to analyze wave propagation in a gain medium without nonlinear time-domain calculation.

  4. A multi-phase ferrofluid flow model with equation of state for thermomagnetic pumping and heat transfer

    Energy Technology Data Exchange (ETDEWEB)

    Aursand, Eskil, E-mail: eskil.aursand@sintef.no; Gjennestad, Magnus Aa.; Yngve Lervåg, Karl; Lund, Halvor

    2016-03-15

    A one-dimensional multi-phase flow model for thermomagnetically pumped ferrofluid with heat transfer is proposed. The thermodynamic model is a combination of a simplified particle model and thermodynamic equations of state for the base fluid. The magnetization model is based on statistical mechanics, taking into account non-uniform particle size distributions. An implementation of the proposed model is validated against experiments from the literature, and found to give good predictions for the thermomagnetic pumping performance. However, the results reveal a very large sensitivity to uncertainties in heat transfer coefficient predictions. - Highlights: • A multi-phase flow model for thermomagnetically pumped ferrofluid is proposed. • An implementation is validated against experiments from the literature. • Predicted thermomagnetic pumping effect agrees with experiments. • However, a very large sensitivity to heat transfer coefficient is revealed.

  5. A note on similarity in single-phase and porous-medium natural convection

    International Nuclear Information System (INIS)

    Lyall, H.G.

    1981-03-01

    The similarity laws for single-phase and porous-medium natural convection are developed. For single-phase flow Nu = Nu(Ra) implies that inertial effects are negligible, while Nu = Nu(Ra.Pr) implies that viscous effects are. The first correlation is adequate for Pr>10, while the second applies for Pr<0.01. For intermediate values of Pr, a more general correlation, Nu = Nu(Ra,Pr) is necessary. For a porous-medium, if inertial effects and dispersion are negligible, Nu* = Nu*(Ra*). However dispersion will only be negligible if the ratio of grain size d to the width of the region L is very small (d/L<< l). If this condition does not hold it is necessary to model d/L. If inertial effects are significant, i.e. the Reynolds number is too large for Darcy's law to apply, a group containing the effective Prandtl number, Pr*, also needs to be modelled for similarity. (author)

  6. MECHANICAL CHARACTERISTICS OF THREE-PHASE INDUCTION MOTORS WITH SINGLE-PHASE POWER SUPPLY

    Directory of Open Access Journals (Sweden)

    V.S. Malyar

    2016-06-01

    Full Text Available Aim. Development of a method for calculating mechanical characteristics of three-phase induction motors with single-phase power supply. Methods. The developed algorithm is based on the high-adequacy mathematical model of motor and projection method for solving the boundary problem for equations of electrical circuits balance presented in the three-phase coordinate system. As a result of asymmetry of power supply to the stator windings, in steady state, flux-linkage and current change according to the periodic law. They are determined by solving the boundary problem. Results. The developed mathematical model allows determining periodic dependence of coordinates as a function of slip and, based on them, mechanical characteristics of motors. Academic novelty. The developed method relies on a completely new mathematical approach to calculation of stationary modes of nonlinear electromagnetic circuits, which allows obtaining periodic solution in a timeless domain. Practical value. Using the developed calculation algorithm, one can select capacitance required to start an induction motor with single-phase power supply and calculate static mechanical characteristics at a given capacitance.

  7. Multi-objective analytical model for optimal sizing of stand-alone photovoltaic water pumping systems

    International Nuclear Information System (INIS)

    Olcan, Ceyda

    2015-01-01

    Highlights: • An analytical optimal sizing model is proposed for PV water pumping systems. • The objectives are chosen as deficiency of power supply and life-cycle costs. • The crop water requirements are estimated for a citrus tree yard in Antalya. • The optimal tilt angles are calculated for fixed, seasonal and monthly changes. • The sizing results showed the validity of the proposed analytical model. - Abstract: Stand-alone photovoltaic (PV) water pumping systems effectively use solar energy for irrigation purposes in remote areas. However the random variability and unpredictability of solar energy makes difficult the penetration of PV implementations and complicate the system design. An optimal sizing of these systems proves to be essential. This paper recommends a techno-economic optimization model to determine optimally the capacity of the components of PV water pumping system using a water storage tank. The proposed model is developed regarding the reliability and cost indicators, which are the deficiency of power supply probability and life-cycle costs, respectively. The novelty is that the proposed optimization model is analytically defined for two-objectives and it is able to find a compromise solution. The sizing of a stand-alone PV water pumping system comprises a detailed analysis of crop water requirements and optimal tilt angles. Besides the necessity of long solar radiation and temperature time series, the accurate forecasts of water supply needs have to be determined. The calculation of the optimal tilt angle for yearly, seasonally and monthly frequencies results in higher system efficiency. It is, therefore, suggested to change regularly the tilt angle in order to maximize solar energy output. The proposed optimal sizing model incorporates all these improvements and can accomplish a comprehensive optimization of PV water pumping systems. A case study is conducted considering the irrigation of citrus trees yard located in Antalya, Turkey

  8. Analysis and MPPT control of a wind-driven three-phase induction generator feeding single-phase utility grid

    Directory of Open Access Journals (Sweden)

    Krishnan Arthishri

    2017-05-01

    Full Text Available In this study, a three-phase diode bridge rectifier and a single-phase voltage source inverter topology has been proposed for feeding single-phase utility grid employing a three-phase induction generator fed from wind energy. A self-excited induction generator configuration has been chosen for wide speed operation of wind turbine system, which gives the scope for extracting maximum power available in the wind. In addition to maximum power point tracking (MPPT, the generator can be loaded to its rated capacity for feeding single-phase utility grid using a three-phase induction machine, whereas it is not possible with existing configurations because of the absence of power converters. For the proposed system, MPPT algorithm has been devised by continuously monitoring the grid current and a proportional resonant controller has been employed for grid synchronisation of voltage source inverter with single-phase grid. A MATLAB/Simulink model of the proposed system has been developed to ascertain its successful working by predetermining the overall performance characteristics. The present proposal has also been tested with sag, swell and distortion in the grid voltage. The control strategy has been implemented using field programmable gate array (FPGA controller with modularised programming approach. The efficacy of the system has been demonstrated with the results obtained from an experimental set-up in the laboratory.

  9. Adjusting output impedance using a PI controller to improve the stability of a single-phase inverter under weak grid

    Directory of Open Access Journals (Sweden)

    Jiao Jiao

    2016-11-01

    Full Text Available Explored in this paper is the grid impedance effect on the stability of a single-phase grid connected inverter with an LC filter based on an analysis of the inverter output impedance. For a single-phase grid connected inverter, a PI controller is often used to regulate the current injected into the grid. However, the control performance can be influenced when the inverter is connected to a weak grid. Also, the utility grid has background harmonic noise, which can make the injected current distorted. Therefore, analysis of the output impedance of a single-phase grid connected inverter is important for the robustness and stability of the system. By modeling the output impedance of inverter, it can be determined that the proportional gain and integral gain of the controller have an effect on the output impedance. Analytical results show that by adjusting the PI controller parameters, the ability for harmonic reduction and stability of the system can be improved. Simulation and experiments using a 1 kW single-phase grid connected inverter verify the effectiveness of the theoretical analysis.

  10. A grid-connected single-phase photovoltaic micro inverter

    Science.gov (United States)

    Wen, X. Y.; Lin, P. J.; Chen, Z. C.; Wu, L. J.; Cheng, S. Y.

    2017-11-01

    In this paper, the topology of a single-phase grid-connected photovoltaic (PV) micro-inverter is proposed. The PV micro-inverter consists of DC-DC stage with high voltage gain boost and DC-AC conversion stage. In the first stage, we apply the active clamp circuit and two voltage multipliers to achieve soft switching technology and high voltage gain. In addition, the flower pollination algorithm (FPA) is employed for the maximum power point tracking (MPPT) in the PV module in this stage. The second stage cascades a H-bridge inverter and LCL filter. To feed high quality sinusoidal power into the grid, the software phase lock, outer voltage loop and inner current loop control method are adopted as the control strategy. The performance of the proposed topology is tested by Matlab/Simulink. A PV module with maximum power 300W and maximum power point voltage 40V is applied as the input source. The simulation results indicate that the proposed topology and the control strategy are feasible.

  11. Self-assembled single-phase perovskite nanocomposite thin films.

    Science.gov (United States)

    Kim, Hyun-Suk; Bi, Lei; Paik, Hanjong; Yang, Dae-Jin; Park, Yun Chang; Dionne, Gerald F; Ross, Caroline A

    2010-02-10

    Thin films of perovskite-structured oxides with general formula ABO(3) have great potential in electronic devices because of their unique properties, which include the high dielectric constant of titanates, (1) high-T(C) superconductivity in cuprates, (2) and colossal magnetoresistance in manganites. (3) These properties are intimately dependent on, and can therefore be tailored by, the microstructure, orientation, and strain state of the film. Here, we demonstrate the growth of cubic Sr(Ti,Fe)O(3) (STF) films with an unusual self-assembled nanocomposite microstructure consisting of (100) and (110)-oriented crystals, both of which grow epitaxially with respect to the Si substrate and which are therefore homoepitaxial with each other. These structures differ from previously reported self-assembled oxide nanocomposites, which consist either of two different materials (4-7) or of single-phase distorted-cubic materials that exhibit two or more variants. (8-12) Moreover, an epitaxial nanocomposite SrTiO(3) overlayer can be grown on the STF, extending the range of compositions over which this microstructure can be formed. This offers the potential for the implementation of self-organized optical/ferromagnetic or ferromagnetic/ferroelectric hybrid nanostructures integrated on technologically important Si substrates with applications in magnetooptical or spintronic devices.

  12. Simulation of the remanence influence on the transient states in a single-phase multiwinding transformer

    Directory of Open Access Journals (Sweden)

    Wilk Andrzej

    2017-03-01

    Full Text Available This paper presents the mathematical model of a single-phase multi-winding core type transformer taking into account magnetic hysteresis phenomenon based on the feedback Preisach model (FPM. The set of loop differential equations was developed for a K-th winding transformer model where the flux linkages of each winding includes flux Φ common to all windings as a function of magneto motive force Θ of all windings. The first purpose of this paper is to implement a hysteresis nonlinearity involved in the Φ(Θ function which also accounts residual magnetic flux. The second purpose of this paper is experimental validation of the developed transformer model in a capacitor discharge test and several different values of residual magnetic flux.

  13. Dynamic modeling and dynamical analysis of pump-turbines in S-shaped regions during runaway operation

    International Nuclear Information System (INIS)

    Zhang, Hao; Chen, Diyi; Wu, Changzhi; Wang, Xiangyu; Lee, Jae-Myung; Jung, Kwang-Hyo

    2017-01-01

    Highlights: • Novel dynamic model of a pump-turbine in S-shaped regions is proposed. • A stability criterion of runaway point is given. • Global dynamic characteristics of the pump-turbine are investigated. • Effects of the slopes of the characteristic curve on the stability are studied. - Abstract: There is a region of pump-turbine operation, often called the S-shaped region, in which one unit rotational speed corresponds to three unit flows or torques. In this paper, the dynamic model of the pump-turbine in S-shaped regions is established by introducing the nonlinear piecewise function of relative parameters. Then, the global bifurcation diagrams of the pump-turbine are presented to analyze its dynamic characteristics in the S-shaped regions. Meanwhile, a stability criterion of runaway point is given based on the established theoretical model. The numerical experiments are conducted on the model and the results are in good agreement with the theoretical analysis. Furthermore, the effects of the characteristic curve slopes on the stability of the pump-turbine are studied by an innovative use of the three-dimensional bifurcation diagrams. Finally, the factors influencing the runaway stability of pump-turbines are also discussed, based on the dynamic analysis.

  14. A dynamic double helical band as a model for cardiac pumping

    Energy Technology Data Exchange (ETDEWEB)

    Grosberg, Anna; Gharib, Morteza [Option in Bioengineering, California Institute of Technology, 1200 E. California Blvd, M/C 205-45, Pasadena, CA 91125 (United States)], E-mail: mgharib@caltech.edu

    2009-06-01

    We address here, by means of finite-element computational modeling, two features of heart mechanics and, most importantly, their timing relationship: one of them is the ejected volume and the other is the twist of the heart. The corner stone of our approach is to take the double helical muscle fiber band as the dominant active macrostructure behind the pumping function. We show that this double helical model easily reproduces a physiological maximal ejection fraction of up to 60% without exceeding the limit on local muscle fiber contraction of 15%. Moreover, a physiological ejection fraction can be achieved independently of the excitation pattern. The left ventricular twist is also largely independent of the type of excitation. However, the physiological relationship between the ejection fraction and twist can only be reproduced with Purkinje-type excitation schemes. Our results indicate that the proper timing coordination between twist and ejection dynamics can be reproduced only if the excitation front originates in the septum region near the apex. This shows that the timing of the excitation is directly related to the productive pumping operation of the heart and illustrates the direction for possible bioinspired pump design.

  15. Modeling of end-pumped Yb:YAG thin-disk lasers with nonuniform temperature distribution.

    Science.gov (United States)

    Zhu, Guangzhi; Zhu, Xiao; Zhu, Changhong; Shang, Jianli; Wan, Hailin; Guo, Fei; Qi, Lijun

    2012-05-10

    A plane wave model with nonuniform temperature distribution in the thin-disk crystal is developed to describe the dynamic behavior of an end-pumped Yb:YAG thin-disk laser. A set of couple-rate equations and 2D stationary heat-conduction equations are derived. The stable temperature distribution in the disk crystal is calculated using a numerical iterative method. The analytic expression is capable of dealing with more practical laser systems than previous works on this subject as it allows for nonuniform temperature distribution in the disk crystal. Based on these results, we examined laser output intensity as a function of pump intensity, dopant concentration, resonator coupler reflectivity, crystal thickness and temperature of cooling liquid.

  16. Experimental study of single-phase pressure drops in coarse particle beds

    Energy Technology Data Exchange (ETDEWEB)

    Clavier, R., E-mail: remi.clavier@irsn.fr [IRSN Cadarache, Saint Paul-lez-Durance (France); Chikhi, N., E-mail: nourdine.chikhi@irsn.fr [IRSN Cadarache, Saint Paul-lez-Durance (France); Fichot, F., E-mail: florian.fichot@irsn.fr [IRSN Cadarache, Saint Paul-lez-Durance (France); Quintard, M., E-mail: Michel.Quintard@imft.fr [Université de Toulouse, Allée Camille Soula, F-31400 Toulouse (France); INPT, UPS, Allée Camille Soula, F-31400 Toulouse (France); IMFT (Institut de Mécanique des Fluides de Toulouse), Allée Camille Soula, F-31400 Toulouse (France); CNRS, F-31400 Toulouse (France)

    2017-02-15

    Motivated by uncertainty reduction in nuclear debris beds coolability, experiments have been conducted on the CALIDE facility in order to investigate single-phase pressure losses in representative debris beds, i.e., high sphericity (>80%) particle beds with small size dispersion (from 1 mm to 10 mm), for which no validated model exists. In this paper, experimental results are presented and analyzed in order to identify a simple correlation for single-phase flow pressure losses generated in this kind of porous media in reflooding flowing conditions, which cover Darcy to weakly turbulent regimes. In the literature, it has been observed that their behavior can be accurately described by a Darcy–Forchheimer law, involving the sum of a linear term and a quadratic non-linear deviation, with respect to the filtration velocity. Expressions for the coefficients of the linear and quadratic terms are determined by assessing the possibility to evaluate equivalent diameters, i.e., characteristic lengths allowing correct predictions of the linear and quadratic terms by the Ergun equation. It has been observed that the Sauter diameter of particles allows a very precise prediction of the linear term, while the quadratic term can be predicted using the product of the Sauter diameter and a sphericity coefficient as an equivalent diameter.

  17. Application of modified k-ω model to predicting cavitating flow in centrifugal pump

    Directory of Open Access Journals (Sweden)

    Hou-lin LIU

    2013-07-01

    Full Text Available Considering the compressibility of the cavity in the cavitating flow, this paper presents a modified k-ω model for predicting the cavitating flow in a centrifugal pump, in which the modified k-ω model and Schnerr-Sauer cavitation model were combined with ANSYS CFX. To evaluate the modified and standard k-ω models, numerical simulations were performed with these two models, respectively, and the calculation results were compared with the experimental data. Numerical simulations were executed with three different values of the flow coefficient, and the simulation results of the modified k-ω model showed agreement with most of the experimental data. The cavitating flow in the centrifugal pump obtained by the modified k-ω model at the design flow coefficient of 0.102, was analyzed. When the cavitation number decreases, the cavity initially generates on the suction side of the blade near the leading edge and then expands to the outlet of the impeller, and the decrease of the total pressure coefficient mainly occurs upstream of the impeller passage, while the downstream remains almost unaffected by the development of cavitation.

  18. Application of modified κ-ω model to predicting cavitating flow in centrifugal pump

    Directory of Open Access Journals (Sweden)

    Hou-lin Liu

    2013-07-01

    Full Text Available Considering the compressibility of the cavity in the cavitating flow, this paper presents a modified κ-ω model for predicting the cavitating flow in a centrifugal pump, in which the modified κ-ω model and Schnerr-Sauer cavitation model were combined with ANSYS CFX. To evaluate the modified and standard κ-ω models, numerical simulations were performed with these two models, respectively, and the calculation results were compared with the experimental data. Numerical simulations were executed with three different values of the flow coefficient, and the simulation results of the modified κ-ω model showed agreement with most of the experimental data. The cavitating flow in the centrifugal pump obtained by the modified κ-ω model at the design flow coefficient of 0.102, was analyzed. When the cavitation number decreases, the cavity initially generates on the suction side of the blade near the leading edge and then expands to the outlet of the impeller, and the decrease of the total pressure coefficient mainly occurs upstream of the impeller passage, while the downstream remains almost unaffected by the development of cavitation.

  19. Modeling and dynamic control simulation of unitary gas engine heat pump

    International Nuclear Information System (INIS)

    Zhao Yang; Haibo Zhao; Zheng Fang

    2007-01-01

    Based on the dynamic model of the gas engine heat pump (GEHP) system, an intelligent control simulation is presented to research the dynamic characteristics of the system in the heating operation. The GEHP system simulation model consists of eight models for its components including a natural gas engine, a compressor, a condenser, an expansion valve, an evaporator, a cylinder jacket heat exchanger, an exhaust gas heat exchanger and an auxiliary heater. The intelligent control model is composed of the prediction controller model and the combined controller model. The Runge-Kutta Fehlberg fourth-fifth order algorithms are used to solve the differential equations. The results show that the model is very effective in analyzing the effects of the control system, and the steady state accuracy of the intelligent control scheme is higher than that of the fuzzy controller

  20. Design modeling of the 100-J diode-pumped solid-state laser for Project Mercury

    Energy Technology Data Exchange (ETDEWEB)

    Orth, C., LLNL

    1998-02-23

    We present the energy, propagation, and thermal modeling for a diode-pumped solid-state laser called Mercury being designed and built at LLNL using Yb:S-FAP [i.e., Yb{sup 3+}-doped Sr{sub 5}(PO{sub 4}){sub 3}F crystals] for the gain medium. This laser is intended to produce 100 J pulses at 1 to 10 ns at 10 Hz with an electrical efficiency of {approximately}10%. Our modeling indicates that the laser will be able to meet its performance goals.

  1. Mathematical model of forming screw profiles of compressor machines and pumps

    Science.gov (United States)

    Panchuk, K. L.; Lyashkov, A. A.; Varepo, L. G.

    2017-10-01

    The article presents the results of mathematical modeling of screw surfaces shaping for compressor machines and pumps. The study is based on a method of curve movable trihedron. A mathematical model of a flat gearing - the basis for a screw formation - is proposed. The model is based on geometric interpretation of plane curve trihedron motions and known in a geometric theory of plane mechanisms of the Bobillier construction. A geometric scheme of this construction was expanded due to introduction of evolutes simulating instantaneous motions of curves trihedra in a construction scheme. As a result, the mathematical model was obtained, which is more complete in comparison with the known models of flat gearing, which makes it possible to perform synthesis and analysis of profiled screws geometry. It realizes both direct and inverse problems of screws profiling with simultaneous obtaining the curvature of the desired profiles in absent ones. The proposed model can be used as a basis of automated system development for mutually enveloping surfaces screws shaping for compressor machines and pumps.

  2. Servo characteristics of single-phase spindle motor in DVD-ROM

    Science.gov (United States)

    Wang, KingYin; Kuei, ChingPing; Chang, SungSan; Lee, YaoYu; Kuo, YuHung

    2000-07-01

    The single-phase DC motor has the low-cost advantage over 3- phase DC motor owing to its easy-assembling and high yield- rate, however, it has larger torque ripple and cogging torque. Single-phase DC motor is currently applied to low profit margin products such as cooling fan. In order to utilize single-phase DC motor to high precision system, for instance, DVD (Digital Versatile Disk), the vibration caused by torque ripple and cogging torque needs to be solved. In this paper, focusing error, tracking error, seeking ability and some velocity control performances are studied when single-phase DC motor is used in DVD related products.

  3. PumpKin: A tool to find principal pathways in plasma chemical models

    Science.gov (United States)

    Markosyan, A. H.; Luque, A.; Gordillo-Vázquez, F. J.; Ebert, U.

    2014-10-01

    PumpKin is a software package to find all principal pathways, i.e. the dominant reaction sequences, in chemical reaction systems. Although many tools are available to integrate numerically arbitrarily complex chemical reaction systems, few tools exist in order to analyze the results and interpret them in relatively simple terms. In particular, due to the large disparity in the lifetimes of the interacting components, it is often useful to group reactions into pathways that recycle the fastest species. This allows a researcher to focus on the slow chemical dynamics, eliminating the shortest timescales. Based on the algorithm described by Lehmann (2004), PumpKin automates the process of finding such pathways, allowing the user to analyze complex kinetics and to understand the consumption and production of a certain species of interest. We designed PumpKin with an emphasis on plasma chemical systems but it can also be applied to atmospheric modeling and to industrial applications such as plasma medicine and plasma-assisted combustion.

  4. European Regional Climate Zone Modeling of a Commercial Absorption Heat Pump Hot Water Heater

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Vishaldeep [ORNL; Shen, Bo [ORNL; Keinath, Chris [Stone Mountain Technologies, Inc., Johnson City; Garrabrant, Michael A. [Stone Mountain Technologies, Inc., Johnson City; Geoghegan, Patrick J [ORNL

    2017-01-01

    High efficiency gas-burning hot water heating takes advantage of a condensing heat exchanger to deliver improved combustion efficiency over a standard non-condensing configuration. The water heating is always lower than the gas heating value. In contrast, Gas Absorption Heat Pump (GAHP) hot water heating combines the efficiency of gas burning with the performance increase from a heat pump to offer significant gas energy savings. An ammonia-water system also has the advantage of zero Ozone Depletion Potential and low Global Warming Potential. In comparison with air source electric heat pumps, the absorption system can maintain higher coefficients of performance in colder climates. In this work, a GAHP commercial water heating system was compared to a condensing gas storage system for a range of locations and climate zones across Europe. The thermodynamic performance map of a single effect ammonia-water absorption system was used in a building energy modeling software that could also incorporate the changing ambient air temperature and water mains temperature for a specific location, as well as a full-service restaurant water draw pattern.

  5. Means-End based Functional Modeling for Intelligent Control: Modeling and Experiments with an Industrial Heat Pump System

    DEFF Research Database (Denmark)

    Saleem, Arshad

    2007-01-01

    The purpose of this paper is to present a Multilevel Flow Model (MFM) of an industrial heat pump system and its use for diagnostic reasoning. MFM is functional modeling language supporting an explicit means-ends intelligent control strategy for large industrial process plants. The model is used...... in several diagnostic experiments analyzing different fault scenarios. The model and results of the experiments are explained and it is shown how MFM based intelligent modeling and automated reasoning can improve the fault diagnosis process significantly....

  6. Cellular ion channel-pump system modeling using switched stochastic differential equations.

    Science.gov (United States)

    Weaver, Jeffrey

    2007-01-01

    This paper identifies a multidimensional random switched process model of a neuron with embedded Ca++ ion channel and pump molecules adiabatically interacting based on local ion concentrations near the cell membrane. The model interprets known physiology of the channels as a coupled set of switched random processes and derives mechanical equations based on concentration flow among different states of the system. Rapid changes to channel barrier energies occurring during channel opening and closing transitions are modeled as another degree of freedom commutating the state of the overall system. An ion reservoir model is used as the primary tool to incorporate stochastic effects in channel operation. The complete model is analyzed numerically and then the equations are used to motivate a stochastic model for closed state dwell times. The result is compared against expected results of a leaky-integrator and known single-channel histograms.

  7. Analytical Determining Of The Steinmetz Equivalent Diagram Elements Of Single-Phase Transformer

    Directory of Open Access Journals (Sweden)

    T. Aly Saandy

    2015-08-01

    Full Text Available This article presents to an analytical calculation methodology of the Steinmetz Equivalent Diagram Elements applied to the prediction of Eddy current loss in a single-phase transformer. Based on the electrical circuit theory the active and reactive powers consumed by the core are expressed analytically in function of the electromagnetic parameters as resistivity permeability and the geometrical dimensions of the core. The proposed modeling approach is established with the duality parallel series. The equivalent diagram elements empirically determined by Steinmetz are analytically expressed using the expressions of the no loaded transformer consumptions. To verify the relevance of the model validations both by simulations with different powers and measurements were carried out to determine the resistance and reactance of the core. The obtained results are in good agreement with the theoretical approach and the practical results.

  8. A unified active damping control for single-phase differential buck inverter with LCL-filter

    DEFF Research Database (Denmark)

    Yao, Wenli; Wang, Xiongfei; Zhang, Xiaobin

    2015-01-01

    and control of a grid-connected differential mode buck inverter with an LCL filter. A generalized small-signal model of the inverter is built first with the averaged switching model. It is shown that the LCL filter resonance merely occurs in the differential mode, while an LC filter resonance exists......The single-phase differential mode buck inverter is recently introduced with a differential mode for power transfer and a common mode for actively decoupling the second-order power oscillation. However, it is limited to islanded applications with an LC filter. This paper addresses the stability...... in the common mode, provided that the filter parameters of the two bridges are kept the same. A unified active damping control approach is then proposed for stabilizing the inverter and improving the transient performance under a wide range of grid impedance. Lastly, experimental tests are carried out...

  9. Dynamic Modeling and Simulation of Deep Geothermal Electric Submersible Pumping Systems

    Directory of Open Access Journals (Sweden)

    Julian Kullick

    2017-10-01

    Full Text Available Deep geothermal energy systems employ electric submersible pumps (ESPs in order to lift geothermal fluid from the production well to the surface. However, rough downhole conditions and high flow rates impose heavy strain on the components, leading to frequent failures of the pump system. As downhole sensor data is limited and often unrealible, a detailed and dynamical model system will serve as basis for deeper understanding and analysis of the overall system behavior. Furthermore, it allows to design model-based condition monitoring and fault detection systems, and to improve controls leading to a more robust and efficient operation. In this paper, a detailed state-space model of the complete ESP system is derived, covering the electrical, mechanical and hydraulic subsystems. Based on the derived model, the start-up phase of an exemplary yet realistic ESP system in the Megawatt range—located at a setting depth of 950 m and producing geothermal fluid of 140 ∘ C temperature at a rate of 0.145 m 3 s − 1 —is simulated in MATLAB/Simulink. The simulation results show that the system reaches a stable operating point with realistic values. Furthermore, the effect of self-excitation between the filter capacitor and the motor inductor can clearly be observed. A full set of parameters is provided, allowing for direct model implementation and reproduction of the presented results.

  10. On modelling, simulation and measurement of fluid power pumps and pipelines

    International Nuclear Information System (INIS)

    Weddfelt, K.

    1992-01-01

    Pressure ripple in fluid power systems is often considered to be a nuisance. It is a major reason for vibrations and noise emission but can also cause functional problems, in extreme causes even fatigue and breakdown of pipes and connections. In order to examine this problem both the sources of pressure ripple and its transmission properties must be considered. A major source of pressure ripple in fluid power systems is positive displacement pumps, a component which is actually a source of flow ripple. A positive displacement pump can be characterized and modelled as a flow source with an internal source impedance. Special measurement techniques must be developed in order to determine these source properties experimentally. Pressure and flow ripple propagate through the pipeline of a fluid power system as waves. When the impedance of the system changes, part of the energy in the wave is being transmitted while the remaining part is reflected. Therefore, the mechanism for standing waves to occur is present, causing resonances and possibly very large pressure pulsations at certain frequencies. Destructive interference between these waves can be used to design so-called reactive attenuators, similar to an automobile muffler, which can be used to acoustically separate the source of flow ripple from the rest of the fluid power system. A mathematical model of wave transmission in pipelines is of fundamental importance to the design of acoustical sound systems. It is of equal importance when modelling and measuring the source characteristics of fluid power pumps. Such a mathematical model must include the transmission and reflection of waves as well as the frequency-dependent losses from viscous friction in the fluid. (au)

  11. Impact of Intragranular Substructure Parameters on the Forming Limit Diagrams of Single-Phase B.C.C. Steels

    Directory of Open Access Journals (Sweden)

    Gérald Franz

    2013-11-01

    Full Text Available An advanced elastic-plastic self-consistent polycrystalline model, accounting for intragranular microstructure development and evolution, is coupled with a bifurcation-based localization criterion and applied to the numerical investigation of the impact of microstructural patterns on ductility of single-phase steels. The proposed multiscale model, taking into account essential microstructural aspects, such as initial and induced textures, dislocation densities, and softening mechanisms, allows us to emphasize the relationship between intragranular microstructure of B.C.C. steels and their ductility. A qualitative study in terms of forming limit diagrams for various dislocation networks, during monotonic loading tests, is conducted in order to analyze the impact of intragranular substructure parameters on the formability of single-phase B.C.C. steels.

  12. Influence of single-phase heat transfer correlations on safety analysis of research reactors with narrow rectangular fuel channels

    International Nuclear Information System (INIS)

    Rawashdeh, A.; Altamimi, R.; Lee, B.; Chung, Y. J.; Park, S.

    2013-01-01

    The influence of different single-phase heat transfer correlations on the fuel temperature and minimum critical heat flux ratio (MCHFR) during a typical accident of a 5 MW research reactor is investigated. A reactor uses plate type fuel, of which the cooling channels have a narrow rectangular shape. RELAP5/MOD3.3 tends to over-predict the Nusselt number (Nu) at a low Reynolds number (Re) region, and therefore the correlation set is modified to properly describe the thermal behavior at that region. To demonstrate the effect of Nu at a low-Re region on an accident analysis, a two-pump failure accident was chosen as a sample problem. In the accident, the downward core flow decreases by a pump coast-down, and then reverses upward by natural convection. During the pump coast-down and flow reversal, the flow undergoes a laminar flow regime which has a different Nu with respect to the correlation sets. Compared to the results by the original RELAP5/MOD3.3, the modified correlation set predicts the fuel temperature to be a little higher than the original value, and the MCHFR to be a little lower than the original value. Although the modified correlation set predicts the fuel temperature and the MCHFR to be less conservative than those calculated from the original correlation of RELAP5/MOD3.3, the maximum fuel temperature and the MCHFR still satisfy the safety acceptance criteria

  13. Performance of Wind Pump Prototype

    African Journals Online (AJOL)

    Mulu

    performance of the wind pump. One year wind speed data collected at 10 m height was extrapolated to the wind pump hub height using wind shear coefficient. The model assumed balanced rotor power and reciprocating pump, hence did not consider the effect of pump size. The theoretical model estimated the average ...

  14. A New Low-Cost Hybrid Switched Reluctance Motor for Adjustable-Speed Pump Applications

    DEFF Research Database (Denmark)

    Lu, Kaiyuan; Rasmussen, Peter Omand; Watkins, Steve

    2011-01-01

    This paper presents a new low-cost hybrid switched reluctance (HSR) motor intended for use in adjustable-speed pump drive systems. The motor is a single-phase motor, driven by a unipolar converter, which uses both the reluctance torque and the permanent magnet interaction torque. Compared...... with conventional single-phase switched reluctance motors, it has an increased torque density. The cogging torque is beneficially used in this motor for reducing the torque ripple. It is demonstrated that such a motor drive system can be a suitable candidate to advantageously compete with the existing motor drive...... systems for low-cost applications. Finite-element models are used to analyze and predict the motor's performance. The proposed motor drive system has been fabricated, and its performance has been tested in the laboratory. These experimental results are also presented....

  15. Structure and magnetism of single-phase epitaxial gamma '-Fe4N

    NARCIS (Netherlands)

    Costa-Kramer, JL; Borsa, DM; Garcia-Martin, JM; Martin-Gonzalez, MS; Boerma, DO; Briones, F

    Single phase epitaxial pure gamma(')-Fe4N films are grown on MgO (001) by molecular beam epitaxy of iron in the presence of nitrogen obtained from a radio frequency atomic source. The epitaxial, single phase nature of the films is revealed by x-ray diffraction and by the local magnetic environment

  16. new topology for single-phase, three-level, spwm vsi with lc filter

    African Journals Online (AJOL)

    level PWM inverter. However, this is not the case with single-phase PWM inverters. In these days, the popular single-phase inverters adopt the full-bridge type using approximate sinusoidal modulation technique. The output voltage in them has two values: zero and pos- itive supply dc voltage levels in the positive half cycle.

  17. Torque Analysis With Saturation Effects for Non-Salient Single-Phase Permanent-Magnet Machines

    DEFF Research Database (Denmark)

    Lu, Kaiyuan; Ritchie, Ewen

    2011-01-01

    The effects of saturation on torque production for non-salient, single-phase, permanent-magnet machines are studied in this paper. An analytical torque equation is proposed to predict the instantaneous torque with saturation effects. Compared to the existing methods, it is computationally faster......-element results, and experimental results obtained on a prototype single-phase permanent-magnet machine....

  18. Air source integrated heat pump simulation model for EnergyPlus

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Bo; New, Joshua; Baxter, Van

    2017-12-01

    An Air Source Integrated Heat Pump (AS-IHP) is an air source, multi-functional spacing conditioning unit with water heating function (WH), which can lead to great energy savings by recovering the condensing waste heat for domestic water heating. This paper summarizes development of the EnergyPlus AS-IHP model, introducing the physics, sub-models, working modes, and control logic. Based on the model, building energy simulations were conducted to demonstrate greater than 50% annual energy savings, in comparison to a baseline heat pump with electric water heater, over 10 US cities, using the EnergyPlus quick-service restaurant template building. We assessed water heating energy saving potentials using AS-IHP versus both gas and electric baseline systems, and pointed out climate zones where AS-IHPs are promising. In addition, a grid integration strategy was investigated to reveal further energy saving and electricity cost reduction potentials, via increasing the water heating set point temperature during off-peak hours and using larger water tanks.

  19. Condition monitoring of shaft of single-phase induction motor using optical sensor

    Science.gov (United States)

    Fulzele, Asmita G.; Arajpure, V. G.; Holay, P. P.; Patil, N. M.

    2012-05-01

    Transmission type of optical technique is developed to sense the condition of rotating shafts from a distance. A parallel laser beam is passed tangential over the surface of rotating shaft of a single phase induction motor and its flickering shadow is received on a photo sensor. Variations in sensor voltage output are observed on a digital storage oscilloscope. It is demonstrated that this signal carries information about shaft defects like miss alignment, play and impacts in bearings along with surface deformities. Mathematical model of signals corresponding to these shaft defects is developed. During the development and testing of the sensor, effects of reflections are investigated, sensing phenomenon is simulated, frequency response of the sensor is obtained and its performance is compared with conventional accelerometer.

  20. Reliability assessment of single-phase grid-connected PV microinverters considering mission profile and uncertainties

    DEFF Research Database (Denmark)

    Zare, Mohammad Hadi; Mohamadian, Mustafa; Wang, Huai

    2017-01-01

    Microinverters usually connect a PV panel to a Single-phase power grid. In such system, the input power is constant while the output power oscillates twice the line frequency. Thus, the input and output power differences should be stored in a storage component, which is typically an electrolytic...... capacitor. However, electrolytic capacitors are usually blamed for their short lifetime. Recently, some active power decoupling methods are introduced in the literature which can takes advantage of high reliable film capacitors. However, some extra switches and diodes are added to the microinverter which...... can influence the microinverter lifetime. This paper investigates the microinverter reliability according to mission profile where it is installed. To get more accurate results, uncertainties in both lifetime model and manufacturing process are considered. The effect of ambient temperature and solar...

  1. Pattern formation in single-phase FAC. A stability analysis of an oxide layer

    Energy Technology Data Exchange (ETDEWEB)

    Zinemanas, Daniel [The Israel Electric Corp., Haifa (Israel). Dept. of Chemistry; Herszage, Amiel [The Israel Electric Corp., Haifa (Israel). Dept. of Energy Technologies Development

    2013-03-15

    Pattern formation is a salient characteristic of the flow-accelerated corrosion process, particularly in single-phase flow, where a typical ''orange peel'' surface texture is normally formed. The process of such pattern formation is, however, not well understood. In order to gain some insight into the role of the various processes and parameters involved in this process, a linear stability analysis of an oxide layer based on the Sanchez-Caldera model was performed. According to the results obtained in this study, it follows that the oxide layer is stable regarding perturbations of the oxide thickness or the reaction constant, but it is unstable in respect to perturbations of the mass transfer coefficient. These results suggest therefore that the flow, and not local surface in homogeneities, plays a central role in the pattern formation process. (orig.)

  2. Harmonics Suppression for Single-Phase Grid-Connected Photovoltaic Systems in Different Operation Modes

    DEFF Research Database (Denmark)

    Yang, Yongheng; Zhou, Keliang; Blaabjerg, Frede

    2013-01-01

    -connected PV inverters may be severely affected in different operation modes. In this paper, a detailed analysis is conducted to reveal the relationship between the harmonics level with the power factor and the current level in the PV systems. A current control solution which employs an Internal Model...... Principle (IMP) is proposed to suppress the harmonic currents injected into the grid. Experiments are carried out to verify the analysis and the performance of the proposed control method. It is demonstrated that the proposed method presents an effective solution to harmonics suppression for single......-phase grid-connected PV systems in different operation modes. Especially, it can remove higher order harmonics effectively leading to a better power quality compared to the Proportional plus Multi-Resonant Controller, and it has less computational burden....

  3. Numerical Investigation of Pressure Fluctuation in Centrifugal Pump Volute Based on SAS Model and Experimental Validation

    Directory of Open Access Journals (Sweden)

    Qiaorui Si

    2014-02-01

    Full Text Available This paper presents an investigation of pressure fluctuation of a single-suction volute-type centrifugal pump, particularly volute casing, by using numerical and experimental methods. A new type of hybrid Reynolds-averaged Navier-Stokes/Large Eddy Simulation, referred to as the shear stress transport-scale-adaptive simulation (SAS model, is employed to study the unsteady flow. Statistical analysis method is adopted to show the pressure fluctuation intensity distribution in the volute channel. A test rig for pressure pulsation measurement is built to validate the numerical simulation results using eight transient pressure sensors in the middle section of the volute wall. Results show that the SAS model can accurately predict the inner flow field of centrifugal pumps. Radial force acting on the impeller presents a star distribution related to the blade number. Pressure fluctuation intensity is strongest near the tongue and shows irregular distribution in the pump casing. Pressure fluctuation is distributed symmetrically at the cross-section of the volute casing because the volute can eliminate the rotational movement of the liquid discharged from the impeller. Blade passing frequency and its multiples indicate the dominant frequency of the monitoring points within the volute, and the low-frequency pulsation, particularly in the shaft component, increases when it operates at off-design condition, particularly with a small flow rate. The reason is that the vortex wave is enhanced at the off-design condition, which has an effect on the axle and is presented in the shaft component in the frequency domain.

  4. Modelling of the work processes high-pressure pump of common rail diesel injection system

    Directory of Open Access Journals (Sweden)

    Botwinska Katarzyna

    2016-01-01

    Full Text Available Common rail injection systems are becoming a more widely used solution in the fuel systems of modern diesel engines. The main component and the characteristic feature of the system is rail injection of the fuel under high pressure, which is passed to the injector and further to the combustion chamber. An important element in this process is the high-pressure pump, continuing adequate pressure in the rail injection system. Common rail (CR systems are being modified in order to optimise their work and virtual simulations are a useful tool in order to analyze the correctness of operation of the system while varying the parameters and settings, without any negative impact on the real object. In one particular study, a computer simulation of the pump high-pressure CR system was made in MatLab environment, based on the actual dimensions of the object – a one-cylinder diesel engine, the Farymann Diesel 18W. The resulting model consists of two parts – the first is responsible for simulating the operation of the high-pressure pump, and the second responsible for simulation of the remaining elements of the CR system. The results of this simulation produced waveforms of the following parameters: fluid flow from the manifold to the injector [m3/s], liquid flow from the manifold to the atmosphere [m3/s], and manifold pressure [Pa]. The simulation results allow for a positive verification of the model and the resulting system could become a useful element of simulation of the entire position and control algorithm.

  5. COSTING MODELS FOR WATER SUPPLY DISTRIBUTION: PART III- PUMPS, TANKS, AND RESERVOIRS

    Science.gov (United States)

    Distribution systems are generally designed to ensure hydraulic reliability. Storage tanks, reservoirs and pumps are critical in maintaining this reliability. Although storage tanks, reservoirs and pumps are necessary for maintaining adequate pressure, they may also have a negati...

  6. TEAMS Model for the HPGF LN2 Pump System Diagnostic Utility Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The engineering design group upgraded the liquid nitrogen pump system at the HPGF. The pump system supports the site-wide liquid nitrogen supply and its operation is...

  7. Energy system investment model incorporating heat pumps with thermal storage in buildings and buffer tanks

    DEFF Research Database (Denmark)

    Hedegaard, Karsten; Balyk, Olexandr

    2013-01-01

    Individual compression heat pumps constitute a potentially valuable resource in supporting wind power integration due to their economic competitiveness and possibilities for flexible operation. When analysing the system benefits of flexible heat pump operation, effects on investments should be ta...

  8. A Performance Prediction Method for Pumps as Turbines (PAT Using a Computational Fluid Dynamics (CFD Modeling Approach

    Directory of Open Access Journals (Sweden)

    Emma Frosina

    2017-01-01

    Full Text Available Small and micro hydropower systems represent an attractive solution for generating electricity at low cost and with low environmental impact. The pump-as-turbine (PAT approach has promise in this application due to its low purchase and maintenance costs. In this paper, a new method to predict the inverse characteristic of industrial centrifugal pumps is presented. This method is based on results of simulations performed with commercial three-dimensional Computational Fluid Dynamics (CFD software. Model results have been first validated in pumping mode using data supplied by pump manufacturers. Then, the results have been compared to experimental data for a pump running in reverse. Experimentation has been performed on a dedicated test bench installed in the Department of Civil Construction and Environmental Engineering of the University of Naples Federico II. Three different pumps, with different specific speeds, have been analyzed. Using the model results, the inverse characteristic and the best efficiency point have been evaluated. Finally, results have been compared to prediction methods available in the literature.

  9. Numerical modelling of pump limiter biasing on TEXTOR-94 and Tore Supra

    International Nuclear Information System (INIS)

    Gerhauser, H.; Claassen, H.A.; Mank, G.; Zagorski, R.; Loarer, T.; Gunn, J.; Boucher, C.

    2002-01-01

    The two-dimensional multifluid code TECXY has been used to model the biasing (with respect to the first wall) of the toroidal belt limiter ALT-II on the tokamak TEXTOR-94 and of the new toroidal pump limiter being installed on Tore Supra tokamak in the framework of the CIEL project. It is well known that the edge flow pattern can be influenced by the poloidal electric drifts from imposing radial electric fields. The modelling with TECXY introduces imprinted bias currents in the scrape-off layer (SOL) for the case of negative (limiter) biasing, and imprinted bias potentials for the case of positive biasing. This allowed us to simulate sufficiently well the experimental I-V characteristics for either biasing of ALT-II and also reproduced the essential features and trends of the observed plasma profiles in the SOL of TEXTOR-94. For negative biasing a moderate improvement of the pumping exhaust efficiency can be achieved in the case of TEXTOR. For Tore Supra, however, only a negligible improvement of the limiter performance with biasing can be predicted, which is explained by the relatively weak drift flows in Tore Supra. (author)

  10. Air source heat pump water heater: Dynamic modeling, optimal energy management and mini-tubes condensers

    International Nuclear Information System (INIS)

    Ibrahim, Oussama; Fardoun, Farouk; Younes, Rafic; Louahlia-Gualous, Hasna

    2014-01-01

    This paper presents a dynamic simulation model to predict the performance of an ASHPWH (air source heat pump water heater). The developed model is used to assess its performance in the Lebanese context. It is shown that for the four Lebanese climatic zones, the expected monthly values of the average COP (coefficient of performance) varies from 2.9 to 5, leading to high efficiencies compared with conventional electric water heaters. The energy savings and GHG (greenhouse gas) emissions reduction are investigated for each zone. Furthermore, it is recommended to use the ASHPWH during the period of highest daily ambient temperatures (noon or afternoon), assuming that the electricity tariff and hot water loads are constant. In addition, an optimal management model for the ASHPWH is developed and applied for a typical winter day of Beirut. Moreover, the developed dynamic model of ASHPWH is used to compare the performance of three similar systems that differ only with the condenser geometry, where results show that using mini-condenser geometries increase the COP (coefficient of performance) and consequently, more energy is saved as well as more GHG emissions are reduced. In addition, the condenser “surface compactness” is increased giving rise to an efficient compact heat exchanger. - Highlights: • Numerical modeling and experimental validation for ASHPWH (air source heat pump water heater). • Optimization of the ASHPWH-condenser length. • Comparison of the ASHPWH with conventional electric water heater according to energy efficiency and green gas house emissions. • Development of an energetic-economic optimal management model for ASHPWH. • Energetic and environmental assessment of ASHPWH with mini-tubes condensers

  11. Modeling optically pumped NMR and spin polarization in GaAs/AlGaAs quantum wells

    Science.gov (United States)

    Saha, D.; Wood, R.; Tokarski, J. T.; McCarthy, L. A.; Bowers, C. R.; Sesti, E. L.; Hayes, S. E.; Kuhns, P. L.; McGill, S. A.; Reyes, A. R.; Sanders, G. D.; Stanton, C. J.

    2014-08-01

    Optically-pumped nuclear magnetic resonance (OPNMR) spectroscopy is an emerging technique to probe electronic and nuclear spin properties in bulk and quantum well semiconductors. In OPNMR, one uses optical pumping with light to create spin-polarized electrons in a semiconductor. The electron spin can be transferred to the nuclear spin bath through the Fermi contact hyperfine interaction which can then be detected by conventional NMR. The resulting NMR signal can be enhanced four to five orders of magnitude or more over the thermal equilibrium signal. In previous work, we studied OPNMR in bulk GaAs where we investigated the strength of the OPNMR signal as a function of the pump laser frequency. This allowed us to study the spin-split valence band. Here we report on OPNMR studies in GaAs/AlGaAs quantum wells. We focus on theoretical calculations for the average electron spin polarization at different photon energies for different values of external magnetic field in both unstrained and strained quantum wells. Our calculations allow us to identify the Landau level transitions which are responsible for the peaks in the photon energy dependence of the OPNMR signal intensity. The calculations are based on the 8- band Pidgeon-Brown model generalized to include the effects of the quantum confinement potential as well as pseudomorphic strain at the interfaces. Optical properties are calculated within the golden rule approximation. Detailed comparison to experiment allows one to accurately determine valence band spin splitting in the quantum wells including the effects of strain.

  12. Insulin Pumps

    Science.gov (United States)

    ... Size: A A A Listen En Español Insulin Pumps Insulin pumps are small computerized devices that deliver insulin in ... tissue and is taped in place. The insulin pump is not an artificial pancreas (because you still ...

  13. Penis Pump

    Science.gov (United States)

    ... your appointment might be less involved. Choosing a penis pump Some penis pumps are available without a ... it doesn't get caught in the ring. Penis pumps for penis enlargement Many advertisements in magazines ...

  14. Economic performance of photovoltaic water pumping systems with business model innovation in China

    International Nuclear Information System (INIS)

    Zhang, Chi; Campana, Pietro Elia; Yang, Jin; Yan, Jinyue

    2017-01-01

    Highlights: • A new business model of PV systems is proposed for PV water pumping systems (PVWP). • Three PVWP and one PV-roof scenarios are analysed to estimate economic performance. • The impacts of market incentives in four PV scenarios are insubstantial for its economic payback. • The PVWP system with added-value products will improve economy potential. - Abstract: Expansion by photovoltaic (PV) technologies in the renewable energy market requires exploring added value integrated with business model innovation. In recent years, a pilot trial of PV water pumping (PVWP) technologies for the conservation of grassland and farmland has been conducted in China. In this paper, we studied the added value of the PVWP technologies with an emphasis on the integration of the value proposition with the operation system and customer segmentation. Using the widely used existing PV business models (PV-roof) as a reference, we evaluated discounted cash flow (DCF) and net present value (NPV) under the scenarios of traditional PV roof, PVWP pilot, PVWP scale-up, and PVWP social network, where further added value via social network was included in the business model. The results show that the integrated PVWP system with social network products significantly improves the performance in areas such as the discounted payback period, internal rate of return (IRR), and return on investment (ROI). We conclude that scenario PVWP social network with business model innovation, can result in value add-ins, new sources of revenue, and market incentives. The paper also suggests that current policy incentives for PV industry are not efficient due to a limited source of revenue, and complex procedures of feed-in tariff verification.

  15. Horizontal ground coupled heat pump: Thermal-economic modeling and optimization

    International Nuclear Information System (INIS)

    Sanaye, Sepehr; Niroomand, Behzad

    2010-01-01

    The modeling and optimizing processes of a Ground Coupled Heat Pump (GCHP) with closed Horizontal Ground Heat eXchanger (HGHX) are presented in this paper. After thermal modeling of GCHP including HGHX, the optimum design parameters of the system were estimated by minimizing a defined objective function (total of investment and operation costs) subject to a list of constraints. This procedure was performed applying Genetic Algorithm technique. For given heating/cooling loads and various climatic conditions, the optimum values of saturated temperature/pressure of condenser and evaporator as well as inlet and outlet temperatures of the water source in cooling and heating modes were predicted. Then, for our case study, the design parameters as well as the configuration of HGHX were obtained. Furthermore, the sensitivity analysis of change in the total annual cost of the system and optimum design parameters with the climatic conditions, cooling/heating capacity, and soil type were discussed.

  16. A two-parameter nondiffusive heat conduction model for data analysis in pump-probe experiments

    Science.gov (United States)

    Ma, Yanbao

    2014-12-01

    Nondiffusive heat transfer has attracted intensive research interests in last 50 years because of its importance in fundamental physics and engineering applications. It has unique features that cannot be described by the Fourier law. However, current studies of nondiffusive heat transfer still focus on studying the effective thermal conductivity within the framework of the Fourier law due to a lack of a well-accepted replacement. Here, we show that nondiffusive heat conduction can be characterized by two inherent material properties: a diffusive thermal conductivity and a ballistic transport length. We also present a two-parameter heat conduction model and demonstrate its validity in different pump-probe experiments. This model not only offers new insights of nondiffusive heat conduction but also opens up new avenues for the studies of nondiffusive heat transfer outside the framework of the Fourier law.

  17. A 1D pulse wave propagation model of the hemodynamics of calf muscle pump function.

    Science.gov (United States)

    Keijsers, J M T; Leguy, C A D; Huberts, W; Narracott, A J; Rittweger, J; van de Vosse, F N

    2015-07-01

    The calf muscle pump is a mechanism which increases venous return and thereby compensates for the fluid shift towards the lower body during standing. During a muscle contraction, the embedded deep veins collapse and venous return increases. In the subsequent relaxation phase, muscle perfusion increases due to increased perfusion pressure, as the proximal venous valves temporarily reduce the distal venous pressure (shielding). The superficial and deep veins are connected via perforators, which contain valves allowing flow in the superficial-to-deep direction. The aim of this study is to investigate and quantify the physiological mechanisms of the calf muscle pump, including the effect of venous valves, hydrostatic pressure, and the superficial venous system. Using a one-dimensional pulse wave propagation model, a muscle contraction is simulated by increasing the extravascular pressure in the deep venous segments. The hemodynamics are studied in three different configurations: a single artery-vein configuration with and without valves and a more detailed configuration including a superficial vein. Proximal venous valves increase effective venous return by 53% by preventing reflux. Furthermore, the proximal valves shielding function increases perfusion following contraction. Finally, the superficial system aids in maintaining the perfusion during the contraction phase and reduces the refilling time by 37%. © 2015 The Authors. International Journal for Numerical Methods in Biomedical Engineering published by John Wiley & Sons Ltd.

  18. LMR [liquid metal reactor] centrifugal pump coastdowns

    International Nuclear Information System (INIS)

    Dunn, F.E.; Malloy, D.J.

    1987-01-01

    A centrifugal pump model which describes the interrelationships of the pump discharge flowrate, pump speed, shaft torque and dynamic head has been implemented based upon existing models. Specifically, the pump model is based upon the dimensionless-homologous pump theory of Wylie and Streeter. Given data from a representative pump, homologous theory allows one to predict the transient characteristics of similarly sized pumps. This homologous pump model has been implemented into both the one-dimensional SASSYS-1 systems analysis code and the three-dimensional COMMIX-1A code. Comparisons have been made both against other pump models (CRBR) and actual pump coastdown data (EBR-II and FFTF). Agreement with this homologous pump model has been excellent. Additionally, these comparisons indicate the validity of applying the medium size pump data of Wylie and Streeter to a range of typical LMR centrifugal pumps

  19. Bedforms as Biocatalytic Filters: A Pumping and Streamline Segregation Model for Nitrate Removal in Permeable Sediments.

    Science.gov (United States)

    Azizian, Morvarid; Grant, Stanley B; Kessler, Adam J; Cook, Perran L M; Rippy, Megan A; Stewardson, Michael J

    2015-09-15

    Bedforms are a focal point of carbon and nitrogen cycling in streams and coastal marine ecosystems. In this paper, we develop and test a mechanistic model, the "pumping and streamline segregation" or PASS model, for nitrate removal in bedforms. The PASS model dramatically reduces computational overhead associated with modeling nitrogen transformations in bedforms and reproduces (within a factor of 2 or better) previously published measurements and models of biogeochemical reaction rates, benthic fluxes, and in-sediment nutrient and oxygen concentrations. Application of the PASS model to a diverse set of marine and freshwater environments indicates that (1) physical controls on nitrate removal in a bedform include the pore water flushing rate, residence time distribution, and relative rates of respiration and transport (as represented by the Damkohler number); (2) the biogeochemical pathway for nitrate removal is an environment-specific combination of direct denitrification of stream nitrate and coupled nitrification-denitrification of stream and/or sediment ammonium; and (3) permeable sediments are almost always a net source of dissolved inorganic nitrogen. The PASS model also provides a mechanistic explanation for previously published empirical correlations showing denitrification velocity (N2 flux divided by nitrate concentration) declines as a power law of nitrate concentration in a stream (Mulholland et al. Nature, 2008, 452, 202-205).

  20. Impact of excessive groundwater pumping on rejuvenation processes in the Bandung basin (Indonesia) as determined by hydrogeochemistry and modeling

    Science.gov (United States)

    Taufiq, Ahmad; Hosono, Takahiro; Ide, Kiyoshi; Kagabu, Makoto; Iskandar, Irwan; Effendi, Agus J.; Hutasoit, Lambok M.; Shimada, Jun

    2017-12-01

    In the Bandung basin, Indonesia, excessive groundwater pumping caused by rapid increases in industrialization and population growth has caused subsurface environmental problems, such as excessive groundwater drawdown and land subsidence. In this study, multiple hydrogeochemical techniques and numerical modeling have been applied to evaluate the recharge processes and groundwater age (rejuvenation). Although all the groundwater in the Bandung basin is recharged at the same elevation at the periphery of the basin, the water type and residence time of the shallow and deep groundwater could be clearly differentiated. However, there was significant groundwater drawdown in all the depression areas and there is evidence of groundwater mixing between the shallow and deep groundwater. The groundwater mixing was traced from the high dichlorodifluoromethane (CFC-12) concentrations in some deep groundwater samples and by estimating the rejuvenation ratio (R) in some representative observation wells. The magnitude of CFC-12 concentration, as an indicator of young groundwater, showed a good correlation with R, determined using 14C activity in samples taken between 2008 and 2012. These correlations were confirmed with the estimation of vertical downward flux from shallower to deeper aquifers using numerical modeling. Furthermore, the change in vertical flux is affected by the change in groundwater pumping. Since the 1970s, the vertical flux increased significantly and reached approximately 15% of the total pumping amount during the 2000s, as it compensated the groundwater pumping. This study clearly revealed the processes of groundwater impact caused by excessive groundwater pumping using a combination of hydrogeochemical methods and modeling.

  1. ASSERT validation against the Stern Laboratories' single-phase pressure drop tests

    International Nuclear Information System (INIS)

    Waddington, G.M.; Kiteley, J.C.; Carver, M.B.

    1995-01-01

    This paper describes the preliminary validation of ASSERT-IV against the single-phase pressure drop tests from the 37-element CHF (critical heat flux) experiments conducted at Stern Laboratories, and shows how this study fits into the overall ASSERT validation plan. The effects on the pressure drop of several friction and form loss models are evaluated, including the geometry-based K-factor model. The choice of friction factor has a small effect on the predicted channel pressure drop, compared to the form loss model choice. Using the uniform K-factors of Hameed, the computed pressure drops are in excellent agreement with the experimental results from the nominal pressure tube tests. For future ASSERT applications, either Hameed's uniform K-factors or the geometry-based model using Idelchik's thick-edged orifice equation are recommended, as are the friction factor correlations of Colebrook-White, Selander, and Aly and Groeneveld. More analysis of the geometry-based K-factor model is required. (author). 23 refs., 4 tabs., 9 figs

  2. Development and testing of portable pump for the induction of profound hypothermia in a Swine model of lethal vascular injuries.

    Science.gov (United States)

    Alam, Hasan B; Casas, Fernando; Chen, Zhang; Smith, William A; Reeves, Andrew; Velmahos, George; de Moya, Marc; Rhee, Peter

    2006-12-01

    Rapid induction of a profound hypothermic state (suspended animation) can maintain viability of key organs during repair of lethal injuries. Conventional cardiopulmonary bypass equipment (roller pump) used to induce and reverse hypothermia is expensive, bulky, requires standard electricity, and is not transportable. Development of a small, portable, battery operated, disposable, pump can logistically facilitate induction and maintenance of hypothermia. In this experiment, a portable prototype pump was tested and its performance was compared with the regular roller pump in a swine model of lethal vascular injuries. Uncontrolled hemorrhage was induced in 16 swine (80-120 lbs) by creating an iliac artery and vein injury (nonlethal). After 30 minutes of pulseless shock, the descending thoracic aorta was lacerated (lethal injury). Through a left thoracotomy approach, a catheter was placed in the aorta and cold organ preservation solution was infused to rapidly (2 degrees C/min) induce hypothermia (10 degrees C) for 60 minutes. The performance of the prototype pump was initially tested in a nonsurvival experiment (four animals). Then, 12 animals were cooled either with (n = 6/group) (1) conventional roller pump or (2) small prototype pump. The injuries were repaired during hypothermic arrest and the animals were re-warmed (0.5 degrees C/min). Whole blood was infused during resuscitation on cardiopulmonary bypass. Surviving animals were closely monitored for 3 weeks for postoperative complications, neurologic deficits, and organ dysfunction. The flow rates and the time needed to induce and reverse profound hypothermia were no different between the prototype and the conventional roller pumps. Three-week survival rates were 83% in both groups. Only a transient increase in liver enzymes, and markers of cellular injury (creatine kinase, lactate dehydrogenase) was noted (no meaningful difference between groups), with no long-term organ dysfunction. In this large animal model

  3. Single-phase and two phase bubbly flow in a T connection: theoretical and experimental study

    International Nuclear Information System (INIS)

    Hervieu, Eric

    1988-01-01

    The objective of this research thesis is to highlight the driving factors of the separation of phases of a bubbly flow in a T junction, and to develop a prediction model. In a first part, the author reports the rigorous formulation of equations averaged on the T volume. He shows that it's not possible to solve globally the problem with these equations. Then, he reports a bibliographical study on the modelling of a bubbly flow, and, based upon this study, highlights intrinsic characteristics of the flow, and explains its dynamic mechanisms. He reports the development of the theoretical model, and describes the experimental installation used to validate it. In the third part, he reports the study of the liquid-gas interaction, and presents the adopted approach: study of the behaviour of an isolated bubble within a single-phase flow. Experimentation is used to check theoretical predictions. Results are used to compute phase separation. The obtained results are again compared with experimental results to validate the global relevance of the model [fr

  4. Centrifugal pumps

    CERN Document Server

    Anderson, HH

    1981-01-01

    Centrifugal Pumps describes the whole range of the centrifugal pump (mixed flow and axial flow pumps are dealt with more briefly), with emphasis on the development of the boiler feed pump. Organized into 46 chapters, this book discusses the general hydrodynamic principles, performance, dimensions, type number, flow, and efficiency of centrifugal pumps. This text also explains the pumps performance; entry conditions and cavitation; speed and dimensions for a given duty; and losses. Some chapters further describe centrifugal pump mechanical design, installation, monitoring, and maintenance. The

  5. Light-Weight, Low-Cost, Single-Phase, Liquid-Cooled Cold Plate (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Narumanchi, S.

    2013-07-01

    This presentation, 'Light-Weight, Low-Cost, Single-Phase Liquid-Cooled Cold Plate,' directly addresses program goals of increased power density, specific power, and lower cost of power electronics components through improved thermal management.

  6. Standard Specification for Sampling Single-Phase Geothermal Liquid or Steam for Purposes of Chemical Analysis

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1983-01-01

    1.1 This specification covers the basic requirements for equipment to be used for the collection of uncontaminated and representative samples from single-phase geothermal liquid or steam. Geopressured liquids are included. See Fig 1.

  7. Modeling and Analysis of Truck Mounted Concrete Pump Boom by Virtual Prototyping

    Directory of Open Access Journals (Sweden)

    Wu Ren

    2017-01-01

    Full Text Available By far there is lack of research on different working conditions between rigid and flexible dynamics of truck mounted concrete pump booms. First a 3D model has been established by using virtual prototyping technology of a 37 m long boom in Pro/Engineering software. Then the rigid body simulation model has been built. Next modal superimposition method is adopted to change the 4 rigid body booms into flexible ones. Kinematics law and dynamic characteristics of 4 common working conditions had been studied then. Next tip displacement and the first boom hydraulic cylinder force of the 4 working conditions between rigid and flexible models have been researched. Furthermore the first natural frequencies of the structure have been calculated. The results show that the frequency of the horizontal condition has the lowest of all and the roof condition has the largest of all. Besides the cylinder forces of the flexible model are larger than the corresponding rigid ones because of the flexible boom vibration. Finally an experiment has been done on a boom test rig which proved that the established simulation model is reasonable and the frequency results are correct. All of these provide design reference to mechanical manipulator as well as reducing product development cost of such mechanism.

  8. Na+/K(+)pump activity in photoreceptors of the blowfly Calliphora : A model analysis based on membrane potential measurements

    NARCIS (Netherlands)

    Gerster, U; Stavenga, DG; Backhaus, W

    Na+/K+-pump activity and intracellular Na+ and K+ concentration changes in blowfly photoreceptors are derived from intracellular potential measurements in vivo with a model based on the Goldman-Hodgkin-Katz theory for membrane currents. The relation between the intracellular Na+ concentration and

  9. Thermodiffusive behaviour of NaCl and KCl aqueous solutions a model for the Na-K pump

    International Nuclear Information System (INIS)

    Gaeta, F.S.; Mita, D.G.; Perna, G.; Scala, G.

    1975-01-01

    In NaCl and KCl aqueous nonisothermal solutions K + inverts its sense of migration within the physiological concentration range; Na + behaves similarly at much lower concentrations. These findings are discussed in relation to solute induced modifications of water structure and of their influence on thermal diffusion. A possible evolutionary model of a thermodiffusive mechanism for the sodium potassium pump is also suggested

  10. Statistical modelling of Fat, Oil and Grease (FOG) deposits in wastewater pump sumps

    NARCIS (Netherlands)

    Nieuwenhuis, E.M.; Post, J.A.B.; Duinmeijer, S.P.A.; Langeveld, J.G.; Clemens, F.H.L.R.

    2018-01-01

    The accumulation of FOG (Fat, Oil and Grease) deposits in sewer pumping stations results in an increase in maintenance costs, malfunctioning of pumps and, a potential increase of wastewater spills in receiving open water bodies. It is thought that a variety of parameters (e.g. geometry of the

  11. Jet pumps hydrdynamics for application on BWRS

    International Nuclear Information System (INIS)

    Girardi, G.; Pitimada, D.

    1979-01-01

    An analysis of single-phase jet-pump hydrodynamics is carried out by this paper with special regard to the applications on cooling water recirculation in the boiling water reactors (BWR). Firstly, in order to asses on efficiency of jet pumps, several theories regarding the hydrodynamic of these machines are also investigated. The results of the above theories are critically analysed and compared regarding to water-jet-pump design, to operational performance curves and to section limits. Some general criteria in jet-pump design are introduced and values of geometric and kinematic parameters are suggested together with losses coefficients which are all concerned with the ''high ratio'' type jet pump of this typical application. Finally, the experimental test program following the sim of this research is briefly described

  12. Compare Energy Use in Variable Refrigerant Flow Heat Pumps Field Demonstration and Computer Model

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Chandan; Raustad, Richard

    2013-07-01

    Variable Refrigerant Flow (VRF) heat pumps are often regarded as energy efficient air-conditioning systems which offer electricity savings as well as reduction in peak electric demand while providing improved individual zone setpoint control. One of the key advantages of VRF systems is minimal duct losses which provide significant reduction in energy use and duct space. However, there is limited data available to show their actual performance in the field. Since VRF systems are increasingly gaining market share in the US, it is highly desirable to have more actual field performance data of these systems. An effort was made in this direction to monitor VRF system performance over an extended period of time in a US national lab test facility. Due to increasing demand by the energy modeling community, an empirical model to simulate VRF systems was implemented in the building simulation program EnergyPlus. This paper presents the comparison of energy consumption as measured in the national lab and as predicted by the program. For increased accuracy in the comparison, a customized weather file was created by using measured outdoor temperature and relative humidity at the test facility. Other inputs to the model included building construction, VRF system model based on lab measured performance, occupancy of the building, lighting/plug loads, and thermostat set-points etc. Infiltration model inputs were adjusted in the beginning to tune the computer model and then subsequent field measurements were compared to the simulation results. Differences between the computer model results and actual field measurements are discussed. The computer generated VRF performance closely resembled the field measurements.

  13. A review of modern advances in analyses and applications of single-phase natural circulation loop in nuclear thermal hydraulics

    International Nuclear Information System (INIS)

    Basu, Dipankar N.; Bhattacharyya, Souvik; Das, P.K.

    2014-01-01

    Highlights: • Comprehensive review of state-of-the-art on single-phase natural circulation loops. • Detailed discussion on growth in solar thermal system and nuclear thermal hydraulics. • Systematic development in scaling methodologies for fabrication of test facilities. • Importance of numerical modeling schemes for stability assessment using 1-D codes. • Appraisal of current trend of research and possible future directions. - Abstract: A comprehensive review of single-phase natural circulation loop (NCL) is presented here. Relevant literature reported since the later part of 1980s has been meticulously surveyed, with occasional obligatory reference to a few pioneering studies originating prior to that period, summarizing the key observations and the present trend of research. Development in the concept of buoyancy-induced flow is discussed, with introduction to flow initiation in an NCL due to instability. Detailed discussion on modern advancement in important application areas like solar thermal systems and nuclear thermal hydraulics are presented, with separate analysis for various reactor designs working on natural circulation. Identification of scaling criteria for designing lab-scale experimental facilities has gone through a series of modification. A systematic analysis of the same is presented, considering the state-of-the-art knowledge base. Different approaches have been followed for modeling single-phase NCLs, including simplified Lorenz system mostly for toroidal loops, 1-D computational modeling for both steady-state and stability characterization and 3-D commercial system codes to have a better flow visualization. Methodical review of the relevant studies is presented following a systematic approach, to assess the gradual progression in understanding of the practical system. Brief appraisal of current research interest is reported, including the use of nanofluids for fluid property augmentation, marine reactors subjected to rolling waves

  14. Power decoupling method for single phase differential buck converter

    DEFF Research Database (Denmark)

    Yao, Wenli; Tang, Yi; Zhang, Xiaobin

    2015-01-01

    inverter to improve the dc link power quality, and an improved active power decoupling method is proposed to achieve ripple power reduction for both AC-DC and DC-AC conversions. The ripple energy storage is realized by the filter capacitors, which are connected between the output terminal and the negative...... generation technique is proposed to provide accurate ripple power compensation, and closed-loop controllers are also designed based on small signal models. The effectiveness of this power decoupling method is verified by detailed simulation studies as well as laboratory prototype experimental results....... dc bus. By properly controlling the differential mode voltage of the capacitors, it is possible to transfer desired energy between the DC port and AC port. The common mode voltage is controlled in such a way that the ripple power on the dc side will be reduced. Furthermore, an autonomous reference...

  15. A Comparison between Boundary and Continuous Conduction Modes in Single Phase PFC Using 600V Range Devices

    DEFF Research Database (Denmark)

    Hernandez Botella, Juan Carlos; Petersen, Lars Press; Andersen, Michael A. E.

    2015-01-01

    This paper presents an analysis and comparison of boundary conduction mode (BCM) and continuous conduction mode (CCM) in single phase power factor correction (PFC) applications. The comparison is based on double pulse tester (DPT) characterization results of state-of-the-art superjunction devices...... in the 600V range. The measured switching energy is used to evaluate the devices performance in a conventional PFC. This data is used together with a mathematical model for prediction of the conducted electromagnetic interference (EMI). This allows comparing the different devices in BCM and CCM operation...... modes and evaluating the performance as a function of the PFC power density and efficiency....

  16. Can the heat transfer coefficients for single-phase flow and for convective flow boiling be equivalent?

    Science.gov (United States)

    Dorao, C. A.; Drewes, S.; Fernandino, M.

    2018-02-01

    During the past few decades, heat transfer during convective flow boiling inside pipes has been widely studied with the goal of unveiling the physics of the process. Different heat transfer mechanisms have been suggested based on different assumptions. This fact has resulted in a large number of models including different dimensionless numbers and in some cases up to a dozen of adjusted parameters. Here, we show that the convective flow boiling heat transfer coefficient is equivalent to the one for single-phase flow when the influence of the vapour velocity is taken into account.

  17. Single-Phase Full-Wave Rectifier as an Effective Example to Teach Normalization, Conduction Modes, and Circuit Analysis Methods

    Directory of Open Access Journals (Sweden)

    Predrag Pejovic

    2013-12-01

    Full Text Available Application of a single phase rectifier as an example in teaching circuit modeling, normalization, operating modes of nonlinear circuits, and circuit analysis methods is proposed.The rectifier supplied from a voltage source by an inductive impedance is analyzed in the discontinuous as well as in the continuous conduction mode. Completely analytical solution for the continuous conduction mode is derived. Appropriate numerical methods are proposed to obtain the circuit waveforms in both of the operating modes, and to compute the performance parameters. Source code of the program that performs such computation is provided.

  18. An experimental and numerical study of developed single phase axial turbulent flow in a smooth rod bundle

    International Nuclear Information System (INIS)

    Hooper, J.D.

    1977-01-01

    A combined experimental and numerical model of a turbulent single phase coolant, flowing axially along the fuel pins of a nuclear reactor, was developed. The experimental rig represented two interconnected subchannels of a square array at a pitch/diameter ratio of 1.193. Air was the working fluid, and measurements were made of the mean radial velocity profiles, wall shear stress variation, turbulence velocity spectra and intensities. The numerically predicted wall shear distribution and mean velocity profiles, obtained using an empirical two-dimensional mixing length and eddy diffusivity concept to represent fluid turbulence, showed good agreement with the experimental results. (Author)

  19. Single phase flow pressure drop and heat transfer in rectangular metallic microchannels

    International Nuclear Information System (INIS)

    Sahar, Amirah M.; Özdemir, Mehmed R.; Fayyadh, Ekhlas M.; Wissink, Jan; Mahmoud, Mohamed M.; Karayiannis, Tassos G.

    2016-01-01

    Numerical simulations were performed using Fluent 14.5 to investigate single phase flow and conjugate heat transfer in copper rectangular microchannels. Two different configurations were simulated: (1) single channel with hydraulic diameter of 0.561 mm and (2) multichannel configuration consisting of inlet and outlet manifolds and 25 channels with hydraulic diameter of 0.409 mm. In the single channel configuration, four numerical models were investigated namely, 2D thin-wall, 3D thin-wall (heated from the bottom), 3D thin-wall (three side heated) and 3D full conjugate models. In the multichannel configuration, only 3D full conjugate model was used. The simulation results of the single channel configuration were validated using experimental data of water as a test fluid while the results of the multichannel configuration were validated using experimental data of R134a refrigerant. In the multichannel configuration, flow distribution among the channels was also investigated. The 3D thin-wall model simulation was conducted at thermal boundary conditions similar to those assumed in the experimental data reduction (uniform heat flux) and showed excellent agreement with the experimental data. However, the results of the 3D full conjugate model demonstrated that there is a significant conjugate effect and the heat flux is not uniformly distributed along the channel resulting in significant deviation compared to the experimental data (more than 50%). Also, the results demonstrated that there is a significant difference between the 3D thin-wall and full conjugate models. The simulation of the multichannel configuration with an inlet manifold having gradual decrease in cross sectional area achieved very reasonable uniform flow distribution among the channels which will provide uniform heat transfer rates across the base of the microchannels.

  20. Experimental investigations on transient single phase flow through perforated plates

    International Nuclear Information System (INIS)

    Casadei, F.

    1983-01-01

    The transient flow of the coolant through the perforated dip-plate during a HCDA in a LMFBR was simulated in a one-dimensional experimental model. Several experiments with water as fluid and with various perforation ratios of the dip-plate and different initial heights of the fluid head over the dip-plate were run. The pressure drop across the dip-plate and the forces acting on the dip-plate and on the upper plug of the reactor vessel were measured in a wide range of the Reynolds and Strouhal numbers. The flow pattern downstreams the perforated plate was filmed with high-speed cameras. The resistance coefficients for the transient flow of the coolant through the perforated plate were obtained as a function of the acceleration. The forces acting on the upper plug and their time integral were compared with those acting on the dip-plate. Finally, using high-speed film pictures the formation of fluid jets downstream the dip-plate was investigated. (orig.)

  1. [Numerical assessment of impeller features of centrifugal blood pump based on fast hemolysis approximation model].

    Science.gov (United States)

    Shou, Chen; Guo, Yongjun; Su, Lei; Li, Yongqian

    2014-12-01

    The impeller profile, which is one of the most important factors, determines the creation of shear stress which leads to blood hemolysis in the internal flow of centrifugal blood pump. The investigation of the internal flow field in centrifugal blood pump and the estimation of the hemolysis within different impeller profiles will provide information to improve the performance of centrifugal blood pump. The SST kappa-omega with low Reynolds correction was used in our laboratory to study the internal flow fields for four kinds of impellers of centrifugal blood pump. The flow fields included distributions of pressure field, velocity field and shear stress field. In addition, a fast numerical hemolysis approximation was adopted to calculate the normalized index of hemolysis (NIH). The results indicated that the pressure field distribution in all kinds of blood pump were reasonable, but for the log spiral impeller pump, the vortex and backflow were much lower than those of the other pumps, and the high shear stress zone was just about 0.004%, and the NIH was 0.0089.

  2. Optically pumped atoms

    CERN Document Server

    Happer, William; Walker, Thad

    2010-01-01

    Covering the most important knowledge on optical pumping of atoms, this ready reference is backed by numerous examples of modelling computation for optical pumped systems. The authors show for the first time that modern scientific computing software makes it practical to analyze the full, multilevel system of optically pumped atoms. To make the discussion less abstract, the authors have illustrated key points with sections of MATLAB codes. To make most effective use of contemporary mathematical software, it is especially useful to analyze optical pumping situations in the Liouville spa

  3. Dynamic model of heat and mass transfer in an unsaturated porous wick of capillary pumped loop

    International Nuclear Information System (INIS)

    Boubaker, Riadh; Platel, Vincent; Berges, Alexis; Bancelin, Mathieu; Hannezo, Edouard

    2015-01-01

    This paper presents a numerical study of a Capillary Pumped Loop evaporator. A two-dimensional unsteady mathematical model of a flat evaporator is developed to simulate heat and mass transfer in unsaturated porous wick with phase change. The liquid–vapor phase change inside the porous wick is described by Langmuir's law. The governing equations are solved by the Finite Element Method. The results are presented then for a sintered nickel wick and methanol as a working fluid. The heat flux required to the transition from the all-liquid wick to the vapor–liquid wick is calculated. The dynamic and thermodynamic behavior of the working fluid in the capillary structure are discussed in this paper. - Highlights: • We develop an unsteady model of two phase flow in porous wick with phase change. • We describe the heat and mass transfer inside the CPL evaporator. • We study the dynamic growth of the vapor pocket inside the porous wick. • The transition from the all liquid wick to the vapor–liquid wick is examined. • Porous wick with large porosity and conductivity reduces the parasitic flux

  4. Gravity gradiometry difference measurement as a tool for monitoring pumping and injection; forward modeling results

    International Nuclear Information System (INIS)

    Creed, R.; Edwards, A.

    1997-01-01

    Gravity gradiometry forward models have been developed at the Idaho National Engineering and Environmental laboratory (INEEL) that can characterize gravity gradient changes with the development of a cone of depression or injection mound in water table aquifers. Difference measurements at long time intervals reduce delayed drainage effects and eliminate the need for determining an initial density structure. Qualitative or semi-quantitative analysis of the gradient signal to determine changes in groundwater distribution with injection or pumping may be possible, particularly if the time varying nature of the signal is of interest. Gravity gradiometer instruments (such as the Gravity Gradient Survey System) have progressed to the point where the complete second order gravity gradient tensor can be measured with an instrument noise level of less than 1 Eotvos (0.1 microgals/meter). Modeling indicates direct gravity measurements for the injection mound perched aquifier case could produce similar signal to noise ratios. However gravity gradients provide 5 independent measurements and due to the common mode nature of the instruments are less susceptible to other effects (tide, latitude, elevation, etc.). The gradients also provide a sharper image of the edge of the anomaly. The systematic identification and removal of specific retention, rainfall and subsidence or uplift effects may be required to make gradiometry difference imaging practical for field use

  5. Modelling of Thermal Behavior of Borehole Heat Exchangers of Geothermal Heat Pump Heating Systems

    Directory of Open Access Journals (Sweden)

    Gornov V.F.

    2016-01-01

    Full Text Available This article reports results of comparing the accuracy of the software package “INSOLAR.GSHP.12”, modeling non-steady thermal behavior of geothermal heat pump heating systems (GHCS and of the similar model “conventional” using finite difference methods for solving spatial non-steady problems of heat conductivity. The software package is based on the method of formulating mathematical models of thermal behavior of ground low-grade heat collection systems developed by INSOLAR group of companies. Equations of mathematical model of spatial non-steady thermal behavior of ground mass of low-grade heat collection system obtained by the developed method have been solved analytically that significantly reduced computing time spent by the software complex “INSOLAR.GSHP.12” for calculations. The method allows to turn aside difficulties associated with information uncertainty of mathematical models of the ground thermal behavior and approximation of external factors affecting the ground. Use of experimentally obtained information about the ground natural thermal behavior in the software package allows to partially take into account the whole complex of factors (such as availability of groundwater, their velocity and thermal behavior, structure and arrangement of ground layers, the Earth’s thermal background, precipitation, phase transformations of moisture in the pore space, and more, significantly influencing the formation of thermal behavior of the ground mass of a low-grade geothermal heat collection system. Numerical experiments presented in the article confirmed the high convergence of the results obtained through the software package “INSOLAR.GSHP.12” with solutions obtained by conventional finite-difference methods.

  6. 3D microstructural evolution of primary recrystallization and grain growth in cold rolled single-phase aluminum alloys

    Science.gov (United States)

    Adam, Khaled; Zöllner, Dana; Field, David P.

    2018-04-01

    Modeling the microstructural evolution during recrystallization is a powerful tool for the profound understanding of alloy behavior and for use in optimizing engineering properties through annealing. In particular, the mechanical properties of metallic alloys are highly dependent upon evolved microstructure and texture from the softening process. In the present work, a Monte Carlo (MC) Potts model was used to model the primary recrystallization and grain growth in cold rolled single-phase Al alloy. The microstructural representation of two kinds of dislocation densities, statistically stored dislocations and geometrically necessary dislocations were quantified based on the ViscoPlastic Fast Fourier transform method. This representation was then introduced into the MC Potts model to identify the favorable sites for nucleation where orientation gradients and entanglements of dislocations are high. Additionally, in situ observations of non-isothermal microstructure evolution for single-phase aluminum alloy 1100 were made to validate the simulation. The influence of the texture inhomogeneity is analyzed from a theoretical point of view using an orientation distribution function for deformed and evolved texture.

  7. Single-phased Fault Location on Transmission Lines Using Unsynchronized Voltages

    Directory of Open Access Journals (Sweden)

    ISTRATE, M.

    2009-10-01

    Full Text Available The increased accuracy into the fault's detection and location makes it easier for maintenance, this being the reason to develop new possibilities for a precise estimation of the fault location. In the field literature, many methods for fault location using voltages and currents measurements at one or both terminals of power grids' lines are presented. The double-end synchronized data algorithms are very precise, but the current transformers can limit the accuracy of these estimations. The paper presents an algorithm to estimate the location of the single-phased faults which uses only voltage measurements at both terminals of the transmission lines by eliminating the error due to current transformers and without introducing the restriction of perfect data synchronization. In such conditions, the algorithm can be used with the actual equipment of the most power grids, the installation of phasor measurement units with GPS system synchronized timer not being compulsory. Only the positive sequence of line parameters and sources are used, thus, eliminating the incertitude in zero sequence parameter estimation. The algorithm is tested using the results of EMTP-ATP simulations, after the validation of the ATP models on the basis of registered results in a real power grid.

  8. POWER FACTOR CORRECTION IN PERMANENT MAGNET BRUSHLESS DC MOTOR DRIVE USING SINGLE-PHASE CUK CONVERTER

    Directory of Open Access Journals (Sweden)

    SANJEEV SINGH

    2010-12-01

    Full Text Available Permanent magnet brushless DC motor (PMBLDCM drives are being employed in many variable speed applications due to their high efficiency, silent operation, compact size, high reliability, ease of control, and low maintenance requirements. These drives have power quality problems and poor power factor at input AC mains as they are mostly fed through diode bridge rectifier based voltage source inverters. To overcome such problems a single-phase single-switch power factor correction AC-DC converter topology based on a Cuk converter is proposed to feed voltage source inverters based PMBLDCM. It focuses on the analysis, design and performance evaluation of the proposed PFC converter topology for a 1.5 kW, 1500 rpm, 400 V PMBLDCM drive used for an air-conditioning system. The proposed PFC converter topology is modelled and its performance is simulated in Matlab-Simulink environment and results show an improved power quality and good power factor in wide speed range of the drive.

  9. Single-phase ProtoDUNE, the Prototype of a Single-Phase Liquid Argon TPC for DUNE at the CERN Neutrino Platform

    CERN Document Server

    Cavanna, F; Touramanis, C

    2017-01-01

    ProtoDUNE-SP is the single-phase DUNE Far Detector prototype that is under construction and will be operated at the CERN Neutrino Platform (NP) starting in 2018. It was proposed to the CERN SPSC in June 2015 (SPSC-P-351) and was approved in December 2015 as experiment NP04 (ProtoDUNE). ProtoDUNE-SP, a crucial part of the DUNE effort towards the construction of the first DUNE 10-kt fiducial mass far detector module (17 kt total LAr mass), is a significant experiment in its own right. With a total liquid argon (LAr) mass of 0.77 kt, it represents the largest monolithic single phase LArTPC detector to be built to date. It is housed in an extension to the EHN1 hall in the North Area, where the CERN NP is providing a new dedicated charged-particle test beamline. ProtoDUNE-SP aims to take its first beam data before the LHC long shutdown (LS2) at the end of 2018. ProtoDUNE-SP prototypes the designs of most of the single-phase DUNE far detector module (DUNE-SP) components at a 1:1 scale, with an extrapolation of abo...

  10. Coordinated single-phase control scheme for voltage unbalance reduction in low voltage network.

    Science.gov (United States)

    Pullaguram, Deepak; Mishra, Sukumar; Senroy, Nilanjan

    2017-08-13

    Low voltage (LV) distribution systems are typically unbalanced in nature due to unbalanced loading and unsymmetrical line configuration. This situation is further aggravated by single-phase power injections. A coordinated control scheme is proposed for single-phase sources, to reduce voltage unbalance. A consensus-based coordination is achieved using a multi-agent system, where each agent estimates the averaged global voltage and current magnitudes of individual phases in the LV network. These estimated values are used to modify the reference power of individual single-phase sources, to ensure system-wide balanced voltages and proper power sharing among sources connected to the same phase. Further, the high X / R ratio of the filter, used in the inverter of the single-phase source, enables control of reactive power, to minimize voltage unbalance locally. The proposed scheme is validated by simulating a LV distribution network with multiple single-phase sources subjected to various perturbations.This article is part of the themed issue 'Energy management: flexibility, risk and optimization'. © 2017 The Author(s).

  11. Searching for Next Single-Phase High-Entropy Alloy Compositions

    Directory of Open Access Journals (Sweden)

    David E. Alman

    2013-10-01

    Full Text Available There has been considerable technological interest in high-entropy alloys (HEAs since the initial publications on the topic appeared in 2004. However, only several of the alloys investigated are truly single-phase solid solution compositions. These include the FCC alloys CoCrFeNi and CoCrFeMnNi based on 3d transition metals elements and BCC alloys NbMoTaW, NbMoTaVW, and HfNbTaTiZr based on refractory metals. The search for new single-phase HEAs compositions has been hindered by a lack of an effective scientific strategy for alloy design. This report shows that the chemical interactions and atomic diffusivities predicted from ab initio molecular dynamics simulations which are closely related to primary crystallization during solidification can be used to assist in identifying single phase high-entropy solid solution compositions. Further, combining these simulations with phase diagram calculations via the CALPHAD method and inspection of existing phase diagrams is an effective strategy to accelerate the discovery of new single-phase HEAs. This methodology was used to predict new single-phase HEA compositions. These are FCC alloys comprised of CoFeMnNi, CuNiPdPt and CuNiPdPtRh, and HCP alloys of CoOsReRu.

  12. Heat pumps

    CERN Document Server

    Macmichael, DBA

    1988-01-01

    A fully revised and extended account of the design, manufacture and use of heat pumps in both industrial and domestic applications. Topics covered include a detailed description of the various heat pump cycles, the components of a heat pump system - drive, compressor, heat exchangers etc., and the more practical considerations to be taken into account in their selection.

  13. Elevated Heat Pump hypothesis validation by using satellite data and CMIP5 climate model simulations

    Science.gov (United States)

    Biondi, R.; Cagnazzo, C.; Cairo, F.; Fierli, F.

    2016-12-01

    Air pollution assumes an important role for the health of the south Asian countries population due to the increasing emission of atmospheric pollutants connected to the population growth and industrial development. At the same time the monsoon rainfall trends and patterns have been changed causing serious economic and societal impacts. In this study we have analyzed the link between the aerosols and the monsoon system focusing the attention on a specific mechanism: the Elevated Heat Pump (EHP) hypothesis. According to the EHP the load of dust, organic carbon and black carbon in the pre-monsoon season over the Indo-Gangetic Plain and the foothills of the Himalayas induces enhanced warming in the middle and upper troposphere and changes the convection patterns. As a consequence the rainfall over northern India in late spring and early summer increases and the rainfall in all India in late summer decreases. However, there are still debated conclusions and large uncertainties in this proposed mechanism with ambiguity and uncertainties coming from the lack of real observations and to the consistency of the measurements. By using Historical Natural runs of 3 different Coupled Model Intercomparison Project Phase 5 (CMIP5) models with interactive aerosol loading, we have analysed the variation of precipitation and atmospheric temperature in correspondence to high and low aerosol load years in a time range of 160 years. For deepening the study and validating the model results, we have also included in our analyses the International Satellite Cloud Climatology Project (ISCCP) Deep Convective Tracking Database and the GPS Radio Occultation (RO) measurements. Our preliminary results with models and the two satellite measurements do not show significant evidence of EHP in terms of convection patterns, while the middle and upper troposphere thermal structure is consistent with previous findings.

  14. Energy efficiency analysis of steam ejector and electric vacuum pump for a turbine condenser air extraction system based on supervised machine learning modelling

    International Nuclear Information System (INIS)

    Strušnik, Dušan; Marčič, Milan; Golob, Marjan; Hribernik, Aleš; Živić, Marija; Avsec, Jurij

    2016-01-01

    Highlights: • Steam ejector pump and electric liquid ring vacuum pump are analysed and modelled. • A supervised machine learning models by using real process data are applied. • The equation of ejector pumped mass flow from steam turbine condenser was solved. • The loss of specific energy capable of work in a SEPS or LRVP component was analysed. • The economic efficiency analysis per different coal heating values was made. - Abstract: This paper compares the vapour ejector and electric vacuum pump power consumptions with machine learning algorithms by using real process data and presents some novelty guideline for the selection of an appropriate condenser vacuum pump system of a steam turbine power plant. The machine learning algorithms are made by using the supervised machine learning methods such as artificial neural network model and local linear neuro-fuzzy models. The proposed non-linear models are designed by using a wide range of real process operation data sets from the CHP system in the thermal power plant. The novelty guideline for the selection of an appropriate condenser vacuum pumps system is expressed in the comparative analysis of the energy consumption and use of specific energy capable of work. Furthermore, the novelty is expressed in the economic efficiency analysis of the investment taking into consideration the operating costs of the vacuum pump systems and may serve as basic guidelines for the selection of an appropriate condenser vacuum pump system of a steam turbine.

  15. A hemodynamic evaluation of the Levitronix Pedivas centrifugal pump and Jostra Hl-20 roller pump under pulsatile and nonpulsatile perfusion in an infant CPB model.

    Science.gov (United States)

    Ressler, Noel; Rider, Alan R; Kunselman, Allen R; Richardson, J Scott; Dasse, Kurt A; Wang, Shigang; Undar, Akif

    2009-01-01

    The hemodynamic comparison of the Jostra HL-20 and the Levitronix PediVAS blood pumps is the focus this study, where pressure-flow waveforms and hemodynamic energy values are analyzed in the confines of a pediatric cardiopulmonary bypass circuit.The pseudo pediatric patient was perfused with flow rates between 500 and 900 ml/min (100 ml/min increments) under pulsatile and nonpulsatile mode. The Levitronix continuous flow pump utilized a customized controller to engage in pulsatile perfusion with equivalent pulse settings to the Jostra HL-20 roller pump. Hemodynamic measurements and waveforms were recorded at the precannula location, while the mean arterial pressure was maintained at 40 mm Hg for each test. Glycerin water was used as the blood analog circuit perfusate. At each flow rate 24 trials were conducted yielding a total of 120 experiments (n=60 pulsatile and n=60 nonpulsatile).Under nonpulsatile perfusion the Jostra roller pump produced small values for surplus hemodynamic energy (SHE) due to its inherent pulsatility, while the Levitronix produced values of essentially zero for SHE. When switching to pulsatile perfusion, the SHE levels for both the Jostra and Levitronix pump made considerable increases. In comparing the two pumps under pulsatile perfusion, the Levitronix PediVAS produced significantly more surplus and total hemodynamic energy than did the Jostra roller pump each pump flow rate.The study suggests that the Levitronix PediVAS centrifugal pump has the capability of achieving quality pulsatile waveforms and delivering more SHE to the pseudo patient than the Jostra HL-20 roller pump. Further studies are warranted to investigate the Levitronix under bovine blood studies and with various pulsatile settings.

  16. Program listing for heat-pump seasonal-performance model (SPM). [CNHSPM

    Energy Technology Data Exchange (ETDEWEB)

    1982-06-30

    The computer program CNHSPM is listed which predicts heat pump seasonal energy consumption (including defrost, cyclic degradation, and supplementary heat) using steady state rating point performance and binned weather data. (LEW)

  17. A mathematical model of the hydraulic system of the universal hosed concrete pump

    OpenAIRE

    Chayka, Denys; Emeljanova, Inga; Andrenko, Pavlo

    2016-01-01

    The paper presents a scheme of a new-design universal pistonless concrete pump with a hydraulic drive and provides a basic diagram of its hydraulic system. To maximize energy efficiency, the designed hydraulic circuit is implemented through the following hydraulic devices: high-torque hydraulic motors, a gear pump, a hydraulic cylinder, hydraulic spreaders, a filter, a safety valve, anticavitation and check valves, a flow controller, and pipelines. The key element in the hydraulic circuit of ...

  18. Benchmarking of grid fault modes in single-phase grid-connected photovoltaic systems

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede; Zou, Zhixiang

    2012-01-01

    Pushed by the booming installations of single-phase photovoltaic (PV) systems, the grid demands regarding the integration of PV systems are expected to be modified. Hence, the future PV systems should become more active with functionalities of low voltage ride-through (LVRT) and the grid support...... capability. The control methods, together with grid synchronization techniques, are responsible for the generation of appropriate reference signals in order to handle ride-through grid faults. Thus, it is necessary to evaluate the behaviors of grid synchronization methods and control possibilities in single...... phase systems under grid faults. The intent of this paper is to present a benchmarking of grid fault modes that might come in future single-phase PV systems. In order to map future challenges, the relevant detection and control strategies are discussed. Some faulty modes are studied experimentally...

  19. Theoretical modelling and experimental study of air thermal conditioning process of a heat pump assisted solid desiccant cooling system

    DEFF Research Database (Denmark)

    Nie, Jinzhe; Li, Zan; Hu, Wenju

    2017-01-01

    purification aimed at improving indoor air quality and reducing building energy consumption. The heat and moisture transfer in adsorption desiccant rotor was theoretical modelled with one-dimensional partial differential equations. The theoretical model was validated with experimental measurements......Taking the integrated gaseous contaminants and moisture adsorption potential of desiccant material, a new heat pump assisted solid desiccant cooling system (HP-SDC) was proposed based on the combination of desiccant rotor with heat pump. The HP-SDC was designed for dehumidification, cooling and air......, and the results showed the model could be used to predict the heat and moisture transfer in desiccant rotor. The air thermal conditioning process and energy consumption of HP-SDC was then experimental measured under varied outdoor thermal environments. Results showed that compared to conventional ventilation...

  20. Heat pumps

    CERN Document Server

    Brodowicz, Kazimierz; Wyszynski, M L; Wyszynski

    2013-01-01

    Heat pumps and related technology are in widespread use in industrial processes and installations. This book presents a unified, comprehensive and systematic treatment of the design and operation of both compression and sorption heat pumps. Heat pump thermodynamics, the choice of working fluid and the characteristics of low temperature heat sources and their application to heat pumps are covered in detail.Economic aspects are discussed and the extensive use of the exergy concept in evaluating performance of heat pumps is a unique feature of the book. The thermodynamic and chemical properties o

  1. [Drug screening model acting on out-membrane protein OprM in pseudomonas aeruginosa efflux pump system].

    Science.gov (United States)

    Tian, Rui; Yu, Li-yan; Xiao, Chun-ling; Zuo, Lian; Yao, Tian-jue; Yang, Li-xia

    2004-08-01

    To establish an efflux pump inhibitor screening model with the out-membrane protein OprM in Pseudomonas aeruginosa efflux pump system as the target point. Efflux pump out-membrane protein gene oprM was obtained from standard Pseudomonas aeruginosa PA01 strain. Expression of OprM protein was induced in E. coli strain HS151 with T-easy vector as the cloning vector, and pMMB67EH as the expression vector. In order to evaluate the function of OprM protein, we measured intracellular tetracycline concentrations with liquid scintillation counter, measured the diameters of bacteriostatic circles with paper disc, and then established a screening model accordingly. OprM protein was highly expressed. Using Pseudomonas aeruginosa as the main detecting bacteria, we established a drug screening model acting on OprM. A total of 1 600 microbial fermentation samples were screened with this model, among which 56 positive strains were found, with a positive rate of 3.5%. OprM plays an important role in drug efflux. The established model has good specificity and maneuverability.

  2. 16 channel WDM regeneration in a single phase-sensitive amplifier through optical Fourier transformation

    DEFF Research Database (Denmark)

    Guan, Pengyu; Da Ros, Francesco; Lillieholm, Mads

    2016-01-01

    We demonstrate simultaneous phase regeneration of 16-WDM DPSK channels using optical Fourier transformation and a single phase-sensitive amplifier. The BERs of 16-WDM×10-Gbit/s phase noise degraded DPSK signals are improved by 0.4-1.3 orders of magnitude......We demonstrate simultaneous phase regeneration of 16-WDM DPSK channels using optical Fourier transformation and a single phase-sensitive amplifier. The BERs of 16-WDM×10-Gbit/s phase noise degraded DPSK signals are improved by 0.4-1.3 orders of magnitude...

  3. Common-Ground-Type Tansformerless Inverters for Single-Phase Solar Photovoltaic Systems

    DEFF Research Database (Denmark)

    Siwakoti, Yam Prasad; Blaabjerg, Frede

    2018-01-01

    This paper proposes a family of novel flying capacitor transformerless inverters for single-phase photovoltaic (PV) systems. Each of the new topologies proposed is based on a flying capacitor principle and requires only four power switches and/or diodes, one capacitor, and a small filter at the o......This paper proposes a family of novel flying capacitor transformerless inverters for single-phase photovoltaic (PV) systems. Each of the new topologies proposed is based on a flying capacitor principle and requires only four power switches and/or diodes, one capacitor, and a small filter...

  4. Challenges in thermal design of industrial single-phase power inverter

    Directory of Open Access Journals (Sweden)

    Ninković Predrag

    2016-01-01

    Full Text Available This paper presents the influence of thermal aspects in design process of an industrial single-phase inverter, choice of its topology and components. Stringent design inputs like very high overload level, demand for natural cooling and very wide input voltage range have made conventional circuit topology inappropriate therefore asking for alternative solution. Different power losses calculations in semiconductors are performed and compared, outlining the guidelines how to choose the final topology. Some recommendations in power magnetic components design are given. Based on the final project, a 20kVA single-phase inverter for thermal power plant supervisory and control system is designed and commissioned.

  5. Stability boundary analysis in single-phase grid-connected inverters with PLL by LTP theory

    OpenAIRE

    Salis, Valerio; Costabeber, Alessando; Cox, Stephen M.; Zanchetta, Pericle; Formentini, Andrea

    2017-01-01

    Stability analysis of power converters in AC net¬works is complex due to the non-linear nature of the conversion systems. Whereas interactions of converters in DC networks can be studied by linearising about the operating point, the extension of the same approach to AC systems poses serious challenges, especially for single-phase or unbalanced three-phase systems. A general method for stability analysis of power converters suitable for single-phase or unbalanced AC networks is presented in th...

  6. Soft-Switched Neutral-Point-Clamped Single-Phase Boost Rectifier

    Science.gov (United States)

    Itoh, Ryozo; Ishizaka, Kouichi

    A soft-switched neutral-point-clamped single-phase boost rectifier capable of compensating the imbalance load voltage is studied. This is based on a single-phase rectifier, in which an inductor is placed in series with the AC supply to resonate with a capacitor connected across the DC output of a full-bridge rectifier and the switching transition is mainly governed by a series resonance. The experimental prototype using insulated-gate bipolar transistors is implemented to investigate the operation under the charge control. The experimental results confirm that the rectifier has a neutral-point-clamp feature providing a good quality AC current.

  7. Similarity analysis and scaling criteria for LWRs under single-phase and two-phase natural circulation

    International Nuclear Information System (INIS)

    Ishii, M.; Kataoka, I.

    1983-03-01

    Scaling criteria for a natural circulation loop under single phase and two-phase flow conditions have been derived. For a single phase case the continuity, integral momentum, and energy equations in one-dimensional area average forms have been used. From this, the geometrical similarity groups, friction number, Richardson number, characteristic time constant ratio, Biot number, and heat source number are obtained. The Biot number involves the heat transfer coefficient which may cause some difficulties in simulating the turbulent flow regime. For a two-phase flow case, the similarity groups obtained from a perturbation analysis based on the one-dimensional drift-flux model have been used. The physical significance of the phase change number, subcooling number, drift-flux number, friction number are discussed and conditions imposed by these groups are evaluated. In the two-phase flow case, the critical heat flux is one of the most important transients which should be simulated in a scale model. The above results are applied to the LOFT facility in case of a natural circulation simulation. Some preliminary conclusions on the feasibility of the facility have been obtained

  8. Similarity analysis and scaling criteria for LWRs under single-phase and two-phase natural circulation

    Energy Technology Data Exchange (ETDEWEB)

    Ishii, M.; Kataoka, I.

    1983-03-01

    Scaling criteria for a natural circulation loop under single phase and two-phase flow conditions have been derived. For a single phase case the continuity, integral momentum, and energy equations in one-dimensional area average forms have been used. From this, the geometrical similarity groups, friction number, Richardson number, characteristic time constant ratio, Biot number, and heat source number are obtained. The Biot number involves the heat transfer coefficient which may cause some difficulties in simulating the turbulent flow regime. For a two-phase flow case, the similarity groups obtained from a perturbation analysis based on the one-dimensional drift-flux model have been used. The physical significance of the phase change number, subcooling number, drift-flux number, friction number are discussed and conditions imposed by these groups are evaluated. In the two-phase flow case, the critical heat flux is one of the most important transients which should be simulated in a scale model. The above results are applied to the LOFT facility in case of a natural circulation simulation. Some preliminary conclusions on the feasibility of the facility have been obtained.

  9. Four-quadrant characteristics of Psb-VVER pumps

    International Nuclear Information System (INIS)

    Lipatov, I.A.; Elkin, I.V.; Antonova, A.I.; Dremin, G.I.; Kapustin, A.V.; Nikonov, S.M.; Rovnov, A.A.; Gudkov, V.I.

    2005-01-01

    This paper represents description of determination of Tunis-1620 pump head and torque characteristics of the integral thermophysical test facility Psb-Ver, obtained for single-phase coolant. Test procedure and main results obtained are described in the paper. (author)

  10. ESTABLISHED MODES AND STATIC CHARACTERISTICS OF THREE-PHASE ASYNCHRONOUS MOTOR POWERED WITH SINGLE PHASE NETWORK

    Directory of Open Access Journals (Sweden)

    V. S. Malyar

    2016-01-01

    Full Text Available A mathematical model is developed to study the operation of three-phase asynchronous motor with squirrel-cage rotor when the stator winding is powered from a single phase network. To create a rotating magnetic field one of the phases is fed through the capacitor. Due to the asymmetry of power feed not only transients, but the steady-state regimes are dynamic, so they are described by differential equations in any coordinate system. Their study cannot be carried out with sufficient adequacy on the basis of known equivalent circuits and require the use of dynamic parameters. In the mathematical model the state equations of the circuits of the stator and rotor are composed in the stationary three phase coordinate system. Calculation of the established mode is performed by solving the boundary problem that makes it possible to obtain the coordinate dependences over the period, without calculation of the transient process. In order to perform it, the original nonlinear differential equations are algebraized by approximating the variables with the use of cubic splines. The resulting nonlinear system of algebraic equations is a discrete analogue of the initial system of differential equations. It is solved by parameter continuation method. To calculate the static characteristics as a function of a certain variable, the system is analytically differentiated, and then numerically integrated over this variable. In the process of integration, Newton's refinement is performed at each step or at every few steps, making it possible to implement the integration in just a few steps using Euler's method. Jacobi matrices in both cases are the same. To account for the current displacement in the rods of the squirrel-cage rotor, each of them, along with the squirrel-cage rings, is divided in height into several elements. This results in several squirrel-cage rotor windings which are represented by three-phase windings with magnetic coupling between them.

  11. Electric Boiler and Heat Pump Thermo-Electrical Models for Demand Side Management Analysis in Low Voltage Grids

    DEFF Research Database (Denmark)

    Diaz de Cerio Mendaza, Iker; Bak-Jensen, Birgitte; Chen, Zhe

    2013-01-01

    on the power system control and operation, created by this unstable way of generation, Demand Side Management turns to be a promising solution. The storage capacity from thermo-electric units, like electric boilers and heat pumps, allows operating them with certain freedom. Hence they can be employed under...... certain coordination, to actively respond to the power system fluctuations. The following paper presents two simple thermo-electrical models of an electrical boiler and an air-source CO2 heat pump system. The purpose is using them in low voltage grids analysis to assess their capacity and flexibility...... as active loads. The models were simulated under different Danish daily domestic hot water and space heating profiles. Results showed that under high heating demand conditions the flexibility of this kind of units may be drastically restricted due to their continuous operation....

  12. Economic COP Optimization of a Heat Pump with Hierarchical Model Predictive Control

    DEFF Research Database (Denmark)

    Tahersima, Fatemeh; Stoustrup, Jakob; Rasmussen, Henrik

    2012-01-01

    A low-temperature heating system is studied in this paper. It consists of hydronic under-floor heating pipes and an air/ground source heat pump. The heat pump in such a setup is conventionally controlled only by feed-forwarding the ambient temperature. Having shown >10% cut-down on electricity bi....... The proposed control strategy is a leap forward towards balanced load control in Smart Grids where individual heat pumps in detached houses contribute to preserve load balance through intelligent electricity pricing policies....... bills by involving feedback control in a previous study, this paper has continued the same line of argument and has investigated effects of a priori knowledge on weather forecast and electricity price profile to alleviate the total electricity cost subject to constraints on resident's thermal comfort...

  13. Estimating the monthly discharge of a photovoltaic water pumping system: Model verification

    International Nuclear Information System (INIS)

    Amer, E.H.; Younes, M.A.

    2006-01-01

    A simple algorithm has been adopted for estimating the long term performance of a photovoltaic water pumping system without battery storage. The method uses the standard solar utilizability correlation equation to calculate the flow rate of the system, knowing an insolation threshold value. The method uses the monthly average solar radiation as the only input. The nonlinear relation between flow rate and solar insolation has been obtained experimentally in a first step and then used for performance prediction. The meteorological data collected instantaneously at the site of the pumping system has been used to obtain the monthly average values for solar radiation that are needed by the method. The method has been validated by predicting the performance of two PV pumping systems. The average output of the systems predicted by the method has been compared with experimental measurements. The estimated discharge differs by about 5% from the experimental measurements

  14. A Novel Flying Capacitor Transformerless Inverter for Single-Phase Grid Connected Solar Photovoltaic System

    DEFF Research Database (Denmark)

    Siwakoti, Yam Prasad; Blaabjerg, Frede

    2016-01-01

    This paper proposes a new single-phase flying capacitor transformerless PV inverter for grid-connected photovoltaic (PV) systems. The neutral of the grid can be directly connected to the negative terminal of the source (PV). It consists of four power switches, one diode, one capacitor and a small...

  15. A single phase multilevel inverter as power converter for 3-phase ...

    African Journals Online (AJOL)

    A single phase multilevel inverter as power converter for 3-phase electric loads. ... m-phase maker was simulated using MATLAB and the results confirmed the excellent perfor-mance of the RBNPS. The listed advantages attained could be incorporated in the design and operation of a converter for an electric drive of a car.

  16. Low Voltage Ride-Through of Single-Phase Transformerless Photovoltaic Inverters

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede; Wang, Huai

    2014-01-01

    , e.g. Low Voltage Ride-Through (LVRT) under grid faults and grid support service. In order to map future challenges, the LVRT capability of three mainstream single-phase transformerless PV inverters under grid faults are explored in this paper. Control strategies with reactive power injections...

  17. PI and repetitive control for single phase inverter based on virtual rotating coordinate system

    Science.gov (United States)

    Li, Mengqi; Tong, Yibin; Jiang, Jiuchun; Liang, Jiangang

    2018-03-01

    Microgrid technology developed rapidly and nonlinear loads were connected increasingly. A new control strategy was proposed for single phase inverter when connected nonlinear loads under island condition. PI and repetitive compound controller was realized under synchronous rotating coordinate system and acquired high quality sinusoidal voltage output without voltage spike when loads step changed. Validity and correctness were verified by simulation using MATLAB/Simulink.

  18. Single-Phase 3L PR Controlled qZS Inverter Connected to the Distorted Grid

    DEFF Research Database (Denmark)

    Makovenko, Elena; Husev, Oleksandr; Roncero-Clemente, Carlos

    2016-01-01

    This paper presents a single-phase three-level NPC qZS inverter connected to a distorted grid using PID and PR regulators. A case study system along with the control strategy are described. Tuning approaches for PID and PR regulators are addressed and validated by means of simulation results...

  19. Hybrid Control Method for a Single Phase PFC using a Low Cost Microcontroller

    DEFF Research Database (Denmark)

    Jakobsen, Lars Tønnes; Nielsen, Nils; Wolf, Christian

    2005-01-01

    This paper presents a hybrid control method for single phase boost PFCs. The high bandwidth current loop is analog while the voltage loop is implemented in an 8-bit microcontroller. The design focuses on minimizing the number of calculations done in the microcontroller. A 1kW prototype has been...

  20. Novel Motion Sensorless Control of Single Phase Brushless D.C. PM Motor Drive, with experiments

    DEFF Research Database (Denmark)

    Lepure, Liviu Ioan; Boldea, Ion; Andreescu, Gheorghe Daniel

    2010-01-01

    A motion sensorless control for single phase permanent magnet brushless d.c. (PM-BLDC) motor drives, based on flux integration and prior knowledge of the PM flux/position characteristic is proposed here and an adequate correction algorithm is adopted, in order to increase the robustness to noise...

  1. Single phase inverter for a three phase power generation and distribution system

    Science.gov (United States)

    Lindena, S. J.

    1976-01-01

    A breadboard design of a single-phase inverter with sinusoidal output voltage for a three-phase power generation and distribution system was developed. The three-phase system consists of three single-phase inverters, whose output voltages are connected in a delta configuration. Upon failure of one inverter the two remaining inverters will continue to deliver three-phase power. Parallel redundancy as offered by two three-phase inverters is substituted by one three-phase inverter assembly with high savings in volume, weight, components count and complexity, and a considerable increase in reliability. The following requirements must be met: (1) Each single-phase, current-fed inverter must be capable of being synchronized to a three-phase reference system such that its output voltage remains phaselocked to its respective reference voltage. (2) Each single-phase, current-fed inverter must be capable of accepting leading and lagging power factors over a range from -0.7 through 1 to +0.7.

  2. Control Method of Single-phase Inverter Based Grounding System in Distribution Networks

    DEFF Research Database (Denmark)

    Wang, Wen; Yan, L.; Zeng, X.

    2016-01-01

    of neutral-to-ground voltage is critical for the safety of distribution networks. An active grounding system based on single-phase inverter is proposed to achieve this objective. Relationship between output current of the system and neutral-to-ground voltage is derived to explain the principle of neutral...

  3. protoDUNE-Single Phase and protDUNE-DualPhase

    CERN Multimedia

    Brice, Maximilien

    2016-01-01

    At the EHN1 two big 8m x 8m x8m detector prototypes (protoDUNE-Single Phase and protDUNE-DualPhase) are being constructed. The aim is to test technologies and detector performances for DUNE, a new generation of LBN neutr

  4. A Generic Topology Derivation Method for Single-phase Converters with Active Capacitive DC-links

    DEFF Research Database (Denmark)

    Wang, Haoran; Wang, Huai; Zhu, Guorong

    2016-01-01

    capacitive DCDC- link solutions, but important aspects of the topology assess-ment, such as the total energy storage, overall capacitive energy buffer ratio, cost, and reliability are still not available. This paper proposes a generic topology derivation method of single-phase power converters...

  5. Single-Phase Phase-Locked Loop Based on Derivative Elements

    DEFF Research Database (Denmark)

    Guan, Qingxin; Zhang, Yu; Kang, Yong

    2017-01-01

    High-performance phase-locked loops (PLLs) are critical for power control in grid-connected systems. This paper presents a new method of designing a PLL for single-phase systems based on derivative elements (DEs). The quadrature signal generator (QSG) is constructed by two DEs with the same...

  6. A review of single-phase grid-connected inverters for photovoltaic modules

    DEFF Research Database (Denmark)

    Kjaer, Soren Baekhoej; Pedersen, John Kim; Blaabjerg, Frede

    2005-01-01

    This review focuses on inverter technologies for connecting photovoltaic (PV) modules to a single-phase grid. The inverters are categorized into four classifications: 1) the number of power processing stages in cascade; 2) the type of power decoupling between the PV module(s) and the single...

  7. A Direct Maximum Power Point Tracking Method for Single-Phase Grid Connected PV Inverters

    DEFF Research Database (Denmark)

    EL Aamri, Faicel; Maker, Hattab; Sera, Dezso

    2018-01-01

    in dynamic conditions, especially in low irradiance when the measurement of signals becomes more sensitive to noise. The proposed MPPT is designed for single-phase single-stage grid-connected PV inverters, and is based on estimating the instantaneous PV power and voltage ripples, using second...

  8. A re-look at critical factors influencing single-phase formation of Ba2 ...

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science; Volume 30; Issue 4. A re-look at critical factors influencing single-phase formation of Ba2Ti9O20 microwave dielectrics. Unnikrishnan Gopinath Dhanya Chandran Seema Ansari Bindu Krishnan Rani Panicker Raghu Natarajan. Electrical Properties Volume 30 Issue 4 August ...

  9. Regeneration of phase unlocked serial multiplexed DPSK signals in a single phase sensitive amplifier

    DEFF Research Database (Denmark)

    Guan, Pengyu; Da Ros, Francesco; Kjøller, Niels-Kristian

    2017-01-01

    We demonstrate phase-regeneration of phase unlocked OTDM-DPSK serial signals in a single phase sensitive amplifier through optical cross-phase modulation. The BER of an 8×10 Gbit/s OTDM-DPSK signal is improved by 2 orders of magnitude....

  10. Analysis of Variable-Speed Operation of Drives with Single-Phase Machines

    Czech Academy of Sciences Publication Activity Database

    Chomát, Miroslav; Schreier, Luděk; Bendl, Jiří

    2007-01-01

    Roč. 52, č. 2 (2007), s. 139-147 ISSN 0001-7043 R&D Projects: GA ČR GA102/06/0215 Institutional research plan: CEZ:AV0Z20570509 Keywords : single-phase machines * induction machines * variable-speed drives Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  11. Synchronization in single-phase grid-connected photovoltaic systems under grid faults

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede

    2012-01-01

    under grid faults. The focus of this paper is put on the benchmarking of synchronization techniques, mainly about phase locked loop (PLL) based methods, in single-phase PV power systems operating under grid faults. Some faulty mode cases are studied at the end of this paper in order to compare...

  12. Potential of enhancing a natural convection loop with a thermomagnetically pumped ferrofluid

    Energy Technology Data Exchange (ETDEWEB)

    Aursand, Eskil; Gjennestad, Magnus Aa.; Lervåg, Karl Yngve, E-mail: karl.lervag@sintef.no; Lund, Halvor

    2016-11-01

    The feasibility of using a thermomagnetically pumped ferrofluid to enhance the performance of a natural convection cooling loop is investigated. First, a simplified analytical estimate for the thermomagnetic pumping action is derived, and then design rules for optimal solenoid and ferrofluid are presented. The design rules are used to set up a medium-scale (1 m, 10–1000 W) case study, which is modeled using a previously published and validated model (Aursand et al. [1]). The results show that the thermomagnetic driving force is significant compared to the natural convection driving force, and may in some cases greatly surpass it. The results also indicate that cooling performance can be increased by factors up to 4 and 2 in the single-phase and two-phase regimes, respectively, even when taking into the account the added heat from the solenoid. The performance increases can alternatively be used to obtain a reduction in heat-sink size by up to 75%. - Highlights: • We consider a thermomagnetically pumped ferrofluid for heat transfer. • The performance of the thermomagnetic pump is compared to natural convection. • The flow is simulated using a two-phase flow model. • The thermomagnetic driving force improves heat transfer significantly.

  13. Centrifugal pumps

    CERN Document Server

    Gülich, Johann Friedrich

    2014-01-01

    This book gives an unparalleled, up-to-date, in-depth treatment of all kinds of flow phenomena encountered in centrifugal pumps including the complex interactions of fluid flow with vibrations and wear of materials. The scope includes all aspects of hydraulic design, 3D-flow phenomena and partload operation, cavitation, numerical flow calculations, hydraulic forces, pressure pulsations, noise, pump vibrations (notably bearing housing vibration diagnostics and remedies), pipe vibrations, pump characteristics and pump operation, design of intake structures, the effects of highly viscous flows, pumping of gas-liquid mixtures, hydraulic transport of solids, fatigue damage to impellers or diffusers, material selection under the aspects of fatigue, corrosion, erosion-corrosion or hydro-abrasive wear, pump selection, and hydraulic quality criteria. As a novelty, the 3rd ed. brings a fully analytical design method for radial impellers, which eliminates the arbitrary choices inherent to former design procedures. The d...

  14. A Generic analytical solution for modelling pumping tests in wells intersecting fractures

    Science.gov (United States)

    Dewandel, Benoît; Lanini, Sandra; Lachassagne, Patrick; Maréchal, Jean-Christophe

    2018-04-01

    The behaviour of transient flow due to pumping in fractured rocks has been studied for at least the past 80 years. Analytical solutions were proposed for solving the issue of a well intersecting and pumping from one vertical, horizontal or inclined fracture in homogeneous aquifers, but their domain of application-even if covering various fracture geometries-was restricted to isotropic or anisotropic aquifers, whose potential boundaries had to be parallel or orthogonal to the fracture direction. The issue thus remains unsolved for many field cases. For example, a well intersecting and pumping a fracture in a multilayer or a dual-porosity aquifer, where intersected fractures are not necessarily parallel or orthogonal to aquifer boundaries, where several fractures with various orientations intersect the well, or the effect of pumping not only in fractures, but also in the aquifer through the screened interval of the well. Using a mathematical demonstration, we show that integrating the well-known Theis analytical solution (Theis, 1935) along the fracture axis is identical to the equally well-known analytical solution of Gringarten et al. (1974) for a uniform-flux fracture fully penetrating a homogeneous aquifer. This result implies that any existing line- or point-source solution can be used for implementing one or more discrete fractures that are intersected by the well. Several theoretical examples are presented and discussed: a single vertical fracture in a dual-porosity aquifer or in a multi-layer system (with a partially intersecting fracture); one and two inclined fractures in a leaky-aquifer system with pumping either only from the fracture(s), or also from the aquifer between fracture(s) in the screened interval of the well. For the cases with several pumping sources, analytical solutions of flowrate contribution from each individual source (fractures and well) are presented, and the drawdown behaviour according to the length of the pumped screened interval of

  15. Natural circulation in single-phase and two-phase flow

    International Nuclear Information System (INIS)

    Cheung, F.B.; El-Genk, M.S.

    1989-01-01

    Natural circulation usually arises in a closed loop between a heat source and a heat sink were the fluid motion is driven by density difference. It may also occur in enclosures or cavities where the flow is induced primarily by temperature or concentration gradients within the fluid. The subject has recently received special attention by the heat transfer and nuclear reactor safety communities because of it importance to the areas of energy extraction, decay, heat removal in nuclear reactors, solar and geothermal heating, and cooling of electronic equipment. Although many new results and physical insights have been gained of the various natural circulation phenomena, a number of critical issues remain unresolved. These include, for example, transition from laminar to turbulent flow, buoyancy-induced turbulent flow modeling, change of flow regimes, flow field visualization, variable property effects, and flow instability. This symposium volume contains papers presented in the Natural Circulation in Single-Phase and Two-Phase Flow session at the 1989 Winter Annual Meeting of ASME, by authors from different countries including the United States, Japan, Canada, and Brazil. The papers deal with experimental and theoretical studies as well as state-of-the-art reviews, covering a broad spectrum of topics in natural circulation including: variable-conductance thermosyphons, microelectronic chip cooling, natural circulation in anisotropic porous media and in cavities, heat transfer in flat plat solar collectors, shutdown heat removal in fast reactors, cooling of light-water and heavy-water reactors. The breadth of papers contained in this volume clearly reflect the importance of the current interest in natural circulation as a means for passive cooling and heating

  16. Pumping life

    DEFF Research Database (Denmark)

    Sitsel, Oleg; Dach, Ingrid; Hoffmann, Robert Daniel

    2012-01-01

    The name PUMPKIN may suggest a research centre focused on American Halloween traditions or the investigation of the growth of vegetables – however this would be misleading. Researchers at PUMPKIN, short for Centre for Membrane Pumps in Cells and Disease, are in fact interested in a large family...... of membrane proteins: P-type ATPase pumps. This article takes the reader on a tour from Aarhus to Copenhagen, from bacteria to plants and humans, and from ions over protein structures to diseases caused by malfunctioning pump proteins. The magazine Nature once titled work published from PUMPKIN ‘Pumping ions...

  17. Electric Boiler and Heat Pump Thermo-Electrical Models for Demand Side Management Analysis in Low Voltage Grids

    DEFF Research Database (Denmark)

    Diaz de Cerio Mendaza, Iker; Bak-Jensen, Birgitte; Chen, Zhe

    2013-01-01

    The last fifteen years many European countries have integrated large percentage of renewable energy on their electricity generation mix. In Denmark the 21.3% of the electricity consumed nowadays is produced by the wind, and it has planned to be the 50% by 2025. In order to front future challenges...... on the power system control and operation, created by this unstable way of generation, Demand Side Management turns to be a promising solution. The storage capacity from thermo-electric units, like electric boilers and heat pumps, allows operating them with certain freedom. Hence they can be employed under...... certain coordination, to actively respond to the power system fluctuations. The following paper presents two simple thermo-electrical models of an electrical boiler and an air-source CO2 heat pump system. The purpose is using them in low voltage grids analysis to assess their capacity and flexibility...

  18. Design and modelling of fast switching efficient seat valves for digital displacement pumps

    DEFF Research Database (Denmark)

    Rømer, Daniel; Johansen, Per; Pedersen, Henrik C.

    2013-01-01

    Digital Displacement Fluid Power Pumps/Motors are promising candidates for revolutionizing the efficiency of fluid power systems, which traditionally has suffered from poor efficiencies, especially at part load. The key to obtain efficient part load operation with digital displacement technology...

  19. Automatic swirl angle measurements for pump intake design

    NARCIS (Netherlands)

    Fockert, A. de; Westende, J.M.C. van 't; Verhaart, F.I.H.

    2014-01-01

    Pre-swirl occurring in pump intake basins influences pump efficiency and lifetime. The exact effect on a pump depends on the pump design. In order to optimize the approach flow towards the pump, physical scale modelling is often applied following the guidelines formulated in pump intake design

  20. Evaluation on the fretting abrasion of heat-transfer tubes of the integrated IHX/primary sodium pump. 1. Workrate analyses model

    International Nuclear Information System (INIS)

    Kisohara, Naoyuki

    2002-05-01

    The cost minimization of commercialized FBR plant systems requires the integration of an intermediate-heat-exchanger (IHX) and a primary sodium mechanical pump into one component. The pump is installed in the center of the integrated component and heat transfer tubes surround the pump. Primary sodium flows down inside the heat transfer tubes and secondary sodium flows up outside the tubes in a zigzag. Therefore, the pump rotation and sodium flow induce the vibration of heat transfer tubes and it leads the tubes to fretting wearing against support plates. Then the tube wearing must be evaluated to confirm its integrity during the plant life span (60 years). However, the knowledge of the pump rotation influence on tube wearing is not sufficiently acquired because the integrated component is a new concept in JNC. To evaluate the tube fretting wearing ratio due to the pump rotation, a new calculation model of FINAS was composed. In the first place, the beam vibration analysis model of a pump shaft, shells, tube bundle etc. of the integrated component reveals its properties such as frequency, amplitude and vibration mode. In the second place, based on the above mentioned vibration analysis, the frequency and amplitude of abrasion between the tubes and support plates can be obtained by a contact analysis model of FINAS. Eventually, this calculation shows that the tube wearing will not affect the tube integrity during the plant life time. However further evaluation by more detailed analysis and abrasion tests are needed to obtain more accurate results. (author)

  1. A residual-based a posteriori error estimator for single-phase Darcy flow in fractured porous media

    KAUST Repository

    Chen, Huangxin

    2016-12-09

    In this paper we develop an a posteriori error estimator for a mixed finite element method for single-phase Darcy flow in a two-dimensional fractured porous media. The discrete fracture model is applied to model the fractures by one-dimensional fractures in a two-dimensional domain. We consider Raviart–Thomas mixed finite element method for the approximation of the coupled Darcy flows in the fractures and the surrounding porous media. We derive a robust residual-based a posteriori error estimator for the problem with non-intersecting fractures. The reliability and efficiency of the a posteriori error estimator are established for the error measured in an energy norm. Numerical results verifying the robustness of the proposed a posteriori error estimator are given. Moreover, our numerical results indicate that the a posteriori error estimator also works well for the problem with intersecting fractures.

  2. Main pumps lost incident in the nuclear power plant Atucha I. Modelling with RELAP5/MOD3.2

    International Nuclear Information System (INIS)

    Ventura, M.A.; Rosso, R.D.

    1998-01-01

    Time evolution of natural circulation in the nuclear power plant Atucha I (CNA-I), in a main pumps lost incident because of the lost of external power feed, is analyzed. It leads to a strong stop transient, without an important blow down, from a forced nominal flow to a natural circulation one. The results are obtained from RELAP5/MOD3.2 code's modeling. The study is based on the refrigeration conditions analysis, during the first minutes of the reactor out of service. Previously to the transient, work had been done to obtain the plant steady state, with design parameters in operation conditions at 100 % of power. The object is that the actual plant state would be represented. In this way, each plant part (steam generators, reactor, pressurizer, pumps) had been modeled in separated form with the appropriate boundary conditions, to be used in the whole circuit simulation. The developed model, had been validated making use of the comparison between the values obtained to the principal thermodynamic parameters with the plant recorded values, in the same incident. The results are satisfactory in a way. On the other hand, it has suggested some modeling changes. The RELAP5/MOD3.2 capability to model the thermodynamic phenomena in a PHWR plant has been verified when, according to the mentioned incident, the flow pass from a nominal forced flow, to one which is governed by natural circulation, still with the CNA-I untypical design conditions. (author) [es

  3. Microcontroller Based SPWM Single-Phase Inverter For Wind Power Application

    Directory of Open Access Journals (Sweden)

    Khin Ohmar Lin

    2017-04-01

    Full Text Available In this paper microcontroller based sinusoidal pulse width modulation SPWM single-phase inverter is emphasized to constant frequency conversion scheme for wind power application. The wind-power generator output voltage and frequency are fluctuated due to the variation of wind velocity. Therefore the AC output voltage of wind-generator is converted into DC voltage by using rectifier circuit and this DC voltage is converted back to AC voltage by using inverter circuit. SPWM technique is used in inverter to get nearly sine wave and reduce harmonic content. The rating of inverter is 500W single-phase 220V 50 Hz. The required SPWM timing pulses for the inverter are generated from the PIC16F877A microcontroller. Circuit simulation was done by using Proteus 7 Professional and MATLABR 2008 software. The software for microcontroller is implemented by using MPASM assembler.

  4. An Open-Loop Grid Synchronization Approach for Single-Phase Applications

    DEFF Research Database (Denmark)

    Golestan, Saeed; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

    2018-01-01

    in the presence of frequency drifts. This is particularly true in single-phase applications, where the lack of multiple independent input signals makes the implementation of the synchronization technique difficult. The aim of this paper is to develop an effective OLS technique for single-phase power and energy...... applications. The proposed OLS method benefits from a straightforward implementation, a fast dynamic response (a response time less than two cycles of the nominal frequency), and a complete immunity against the DC component in the grid voltage. In addition, the designed OLS method totally blocks (significantly...... attenuates) all harmonics up to the aliasing point under a nominal (off-nominal) frequency. The effectiveness of the designed OLS technique is verified using comparative experimental results....

  5. Ion beam induced single phase nanocrystalline TiO2 formation

    Science.gov (United States)

    Rukade, Deepti A.; Tribedi, L. C.; Bhattacharyya, Varsha

    2014-06-01

    Single phase TiO2 nanostructures are fabricated by oxygen ion implantation (60 keV) at fluence ranging from 1×1016 ions/cm2 to 1×1017 ions/cm2 in titanium thin films deposited on fused silica substrate and subsequent thermal annealing in argon atmosphere. GAXRD and Raman spectroscopy study reveals formation of single rutile phases of TiO2. Particle size is found to vary from 29 nm to 35 nm, establishing nanostructure formation. Nanostructure formation is also confirmed by the quantum confinement effect manifested by the blueshift of the UV-vis absorption spectra. Photoluminescence spectra show peaks corresponding to TiO2 rutile phase and reveal the presence of oxygen defects due to implantation. The controlled synthesis of single phase nanostructure is attributed to ion induced defects and post-implantation annealing. It is observed that the size of the nanostructures formed is strongly dependent on the ion fluence.

  6. A New Power Calculation Method for Single-Phase Grid-Connected Systems

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede

    2013-01-01

    A new method to calculate average active power and reactive power for single-phase systems is proposed in this paper. It can be used in different applications where the output active power and reactive power need to be calculated accurately and fast. For example, a grid-connected photovoltaic...... system in low voltage ride through operation mode requires a power feedback for the power control loop. Commonly, a Discrete Fourier Transform (DFT) based power calculation method can be adopted in such systems. However, the DFT method introduces at least a one-cycle time delay. The new power calculation...... method, which is based on the adaptive filtering technique, can achieve a faster response. The performance of the proposed method is verified by experiments and demonstrated in a 1 kW single-phase grid-connected system operating under different conditions.Experimental results show the effectiveness...

  7. An efficiency improved single-phase PFC converter for electric vehicle charger applications

    DEFF Research Database (Denmark)

    Zhu, Dexuan; Tang, Yi; Jin, Chi

    2013-01-01

    This paper presents an efficiency improved single-phase power factor correction (PFC) converter with its target application to plug-in hybrid electric vehicle (PHEV) charging systems. The proposed PFC converter features sinusoidal input current, three-level output characteristic, and wide range...... of output DC voltage. Moreover, the involved DC/DC buck conversion stage may only need to convert partial input power rather than full scale of input power, and therefore the system overall efficiency can be much improved. Through proper control of the buck converter, it is also possible to mitigate...... the double-line frequency ripple power that is inherent in a single-phase AC/DC system. Both simulation and experimental results are presented to show the effectiveness of this converter....

  8. Benchmarking of Grid Fault Modes in Single-Phase Grid-Connected Photovoltaic Systems

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede; Zou, Zhixiang

    2013-01-01

    Pushed by the booming installations of singlephase photovoltaic (PV) systems, the grid demands regarding the integration of PV systems are expected to be modified. Hence, the future PV systems should become more active with functionalities of Low Voltage Ride-Through (LVRT) and grid support...... capability. The control methods, together with grid synchronization techniques, are responsible for the generation of appropriate reference signals in order to handle ride-through grid faults. Thus, it is necessary to evaluate the behaviors of grid synchronization methods and control possibilities in single...... phase systems under grid faults. The intent of this paper is to present a benchmarking of grid fault modes that might come in future single-phase PV systems. In order to map future challenges, the relevant synchronization and control strategies are discussed. Some faulty modes are studied experimentally...

  9. 100-nm thick single-phase wurtzite BAlN films with boron contents over 10%

    KAUST Repository

    Li, Xiaohang

    2017-01-11

    Growing thicker BAlN films while maintaining single-phase wurtzite structure and boron content over 10% has been challenging. In this study, we report on the growth of 100 nm-thick single-phase wurtzite BAlN films with boron contents up to 14.4% by MOCVD. Flow-modulated epitaxy was employed to increase diffusion length of group-III atoms and reduce parasitic reactions between the metalorganics and NH3. A large growth efficiency of ∼2000 μm mol−1 was achieved as a result. Small B/III ratios up to 17% in conjunction with high temperatures up to 1010 °C were utilized to prevent formation of the cubic phase and maintain wurtzite structure.

  10. Modelling of a Nitrogen X-ray Laser pumped by Capillary Discharge

    Czech Academy of Sciences Publication Activity Database

    Vrba, Pavel; Vrbová, M.; Bobrova, N. A.; Sasorov, P. V.

    2005-01-01

    Roč. 3, č. 4 (2005), s. 564-580 ISSN 1644-3608 R&D Projects: GA MŠk(CZ) 1P04LA235 Institutional research plan: CEZ:AV0Z20430508 Keywords : MHD simulations * Z-pinch * Ion kinetics * Recombination Pumping * X-Ray laser Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 0.524, year: 2005

  11. Simulation of the phenomenon of single-phase and two-phase natural circulation

    International Nuclear Information System (INIS)

    Castrillo, Lazara Silveira

    1998-02-01

    Natural convection phenomenon is often used to remove the residual heat from the surfaces of bodies where the heat is generated e.g. during accidents or transients of nuclear power plants. Experimental study of natural circulation can be done in small scale experimental circuits and the results can be extrapolated for larger operational facilities. The numerical analysis of transients can be carried out by using large computational codes that simulate the thermohydraulic behavior in such facilities. The computational code RELAP5/MOD2, (Reactor Excursion and Leak Analysis Program) was developed by U.S. Nuclear Regulatory Commissions's. Division of Reactor Safety Research with the objective of analysis of transients and postulated accidents in the light water reactor (LWR) systems, including small and large ruptures with loss of coolant accidents (LOCA's). The results obtained by the simulation of single-phase and two-phase natural circulation, using the RELAP5/MOD2, are presented in this work. The study was carried out using the experimental circuit built at the 'Departamento de Engenharia Quimica da Escola Politecnica da Universidade de Sao Paulo'. In the circuit, two experiments were carried out with different conditions of power and mass flow, obtaining a single-phase regime with a level of power of 4706 W and flow of 5.10 -5 m 3 /s (3 l/min) and a two-phase regime with a level of power of 6536 W and secondary flow 2,33.10 -5 m 3 /s (1,4 l/min). The study allowed tio evaluate the capacity of the code for representing such phenomena as well as comparing the transients obtained theoretically with the experimental results. The comparative analysis shows that the code represents fairly well the single-phase transient, but the results for two-phase transients, starting from the nodalization and calibration used for the case single-phase transient, did not reproduce faithfully some experimental results. (author)

  12. Strain-hardening in nano-structured single phase steels: mechanisms and control.

    Science.gov (United States)

    Bouaziz, O; Barbier, D

    2012-11-01

    The detrimental effect of grain size refinement on the strain hardening is highlighted in single phase steels. A physical based approach for understanding the underlying mechanisms is presented. In order to overcome this limitation a promising metallurgical route exploiting the thermal stability of mechanically induced twins in austenitic steels has been successfully applied to a stainless grade confirming the opportunity to get nano-structured alloys exhibiting high yield stress with high strain-hardening.

  13. A New Synchronous Reference Frame-Based Method for Single-Phase Shunt Active Power Filters

    DEFF Research Database (Denmark)

    Monfared, Mohammad; Golestan, Saeed; Guerrero, Josep M.

    2013-01-01

    This paper deals with the design of a novel method in the synchronous reference frame (SRF) to extract the reference compensating current for single-phase shunt active power filters (APFs). Unlike previous works in the SRF, the proposed method has an innovative feature that it does not need the f...... the excellent performance of the suggested approach. Theoretical evaluations are confirmed by experimental results....

  14. Physical investigation of square cylinder array dynamical response under single-phase cross-flow

    International Nuclear Information System (INIS)

    Longatte, E.; Baj, F.

    2014-01-01

    Fluid structure interaction and flow-induced vibration in square cylinder arrangement under single-phase incompressible laminar cross flow are investigated in the present paper. Dynamic instability governed by damping generation is studied without any consideration about mixing with turbulence effects. Conservative and non-conservative effects are pointed out and dynamical stability limit sensitivity to physical parameters is analyzed. Finally the influence of key physical parameters on fluid solid dynamics interaction is quantified. (authors)

  15. Decoupling of Fluctuating Power in Single-Phase Systems Through a Symmetrical Half-Bridge Circuit

    DEFF Research Database (Denmark)

    Tang, Yi; Blaabjerg, Frede; Loh, Poh Chiang

    2015-01-01

    Single-phase ac/dc or dc/ac systems are inherently subject to the harmonic disturbance that is caused by the well-known double-line frequency ripple power. This issue can be eased through the installation of bulky electrolytic capacitors in the dc link. Unfortunately, such passive filtering...... power decoupling method, and both the input current and output voltage of the converter can be well regulated even when very small dc-link capacitors are employed....

  16. A re-look at critical factors influencing single-phase formation of Ba2 ...

    Indian Academy of Sciences (India)

    TECS

    BaSnO3, B2O3 etc, single-phase 2: 9 has been achieved through solid-state route (Yu et al 1994; Lin and Robert. 1999; Wang et al 2003). It is recorded in literature that phase pure 2:9 ceramics without any stabilizing agent will result in better material for microwave dielectric applica- tions (Lin et al 1997; Lin and Robert ...

  17. Single-phase DECT with VNCT compared with three-phase CTU in patients with haematuria

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jung Jae; Park, Byung Kwan; Kim, Chan Kyo [Sungkyunkwan University School of Medicine, Department of Radiology, Samsung Medical Center, Seoul (Korea, Republic of)

    2016-10-15

    To retrospectively evaluate the diagnostic performance of single-phase dual-energy CT (DECT) with virtual non-contrast CT (VNCT) compared with three-phase CT urography (CTU) in patients with haematuria. A total of 296 patients underwent three-phase CTU (NCT at 120 kVp; nephrographic phase and excretory phase DECTs at 140 kVp and 80 kVp) owing to haematuria. Diagnostic performances of CT scans were compared for detecting urothelial tumours and urinary stones. Dose-length product (DLP) was compared in relation to single-phase DECT and three-phase CTU Dose-length product (DLP) was compared in relation to single-phase DECT and three-phase CTU. Sensitivity and specificity for tumour were 95 % (19/20) and 98.9 % (273/276) on CTU, 95 % (19/20) and 98.2 % (271/276) on nephrographic phase DECT, and 90 % (18/20) and 98.2 % (271/276) on excretory phase DECT (P > 0.1). Of the 148 stones detected on NCT, 108 (73 %) and 100 (67.6 %) were detected on nephrographic phase and excretory phase VNCTs, respectively. The mean size of stones undetected on nephrographic and excretory VNCTs was measured as 1.5 ± 0.5 mm and 1.6 ± 0.6 mm, respectively. The mean DLPs of three-phase CTU, nephrographic phase DECT and excretory phase DECT were 1076 ± 248 mGy . cm, 410 ± 98 mGy . cm, and 360 ± 87 mGy . cm, respectively (P < 0.001). Single-phase DECT has a potential to replace three-phase CTU for detecting tumours with a lower radiation dose. (orig.)

  18. Numerical Simulation of a Single-Phase Flow Through Fractures with Permeable, Porous and Non-Ductile Walls

    Directory of Open Access Journals (Sweden)

    N. Pour Mahmoud

    2017-10-01

    Full Text Available This paper attempts to study flows within fractures through a set of numerical simulations. In addition, a special care is given to hydraulic features and characteristics of fractures. The research is performed through the application of calculative fluid dynamics and a finite volume discrete schema. The investigated flows are laminar, single-phase and stable flows of water and air through fractures with penetrable walls. The selected fracture geometry is inspired from the tomographic scan of a stone fracture. Water and air are modeled in fractures with permeable walls and different permeability levels. It has been observed that in case of permeable matrixes, the friction coefficient is lower compared to impermeable matrixes. In fact permeability reduced friction. In addition, highest pressure drops were observed in areas with smaller fracture diaphragms. Nonetheless, the surrounding area of the fracture is analyzed with the consideration of Darcy's rule.

  19. A Lagging Model for Describing Drawdown Induced by a Constant-Rate Pumping in a Leaky Confined Aquifer

    Science.gov (United States)

    Lin, Ye-Chen; Yeh, Hund-Der

    2017-10-01

    This study proposes a generalized Darcy's law with considering phase lags in both the water flux and drawdown gradient to develop a lagging flow model for describing drawdown induced by constant-rate pumping (CRP) in a leaky confined aquifer. The present model has a mathematical formulation similar to the dual-porosity model. The Laplace-domain solution of the model with the effect of wellbore storage is derived by the Laplace transform method. The time-domain solution for the case of neglecting the wellbore storage and well radius is developed by the use of Laplace transform and Weber transform. The results of sensitivity analysis based on the solution indicate that the drawdown is very sensitive to the change in each of the transmissivity and storativity. Also, a study for the lagging effect on the drawdown indicates that its influence is significant associated with the lag times. The present solution is also employed to analyze a data set taken from a CRP test conducted in a fractured aquifer in South Dakota, USA. The results show the prediction of this new solution with considering the phase lags has very good fit to the field data, especially at early pumping time. In addition, the phase lags seem to have a scale effect as indicated in the results. In other words, the lagging behavior is positively correlated with the observed distance in the Madison aquifer.

  20. On the prediction of single-phase forced convection heat transfer in narrow rectangular channels

    International Nuclear Information System (INIS)

    Ghione, Alberto; Noel, Brigitte; Vinai, Paolo; Demazière, Christophe

    2014-01-01

    In this paper, selected heat transfer correlations for single-phase forced convection are assessed for the case of narrow rectangular channels. The work is of interest in the thermal-hydraulic analysis of the Jules Horowitz Reactor (JHR), which is a research reactor under construction at CEA-Cadarache (France). In order to evaluate the validity of the correlations, about 300 tests from the SULTAN-JHR database were used. The SULTAN-JHR program was carried out at CEA-Grenoble and it includes different kinds of tests for two different vertical rectangular channels with height of 600 mm and gap of 1.51 and 2.16 mm. The experimental conditions range between 2 - 9 bar for the pressure; 0.5 - 18 m/s for the coolant velocity and 0.5 - 7.5 MW/m 2 for the heat flux (whose axial distribution is uniform). Forty-two thermocouples and eight pressure taps were placed at several axial locations, measuring wall temperature and pressure respectively. The analysis focused on turbulent flow with Reynolds numbers between 5.5 x 10 3 - 2.4 x 10 5 and Prandtl numbers between 1.5 - 6. It was shown that standard correlations as the Dittus-Boelter and Seider-Tate significantly under-estimate the heat transfer coefficient, especially at high Reynolds number. Other correlations specifically designed for narrow rectangular channels were also taken into account and compared. The correlation of Popov-Petukhov in the form suggested by Siman-Tov still under-estimates the heat transfer coefficient, even if slight improvements could be seen. A better agreement for the tests with gap equal to 2.16 mm could be found with the correlation of Ma and the one of Liang. However the heat transfer coefficient when the gap is equal to 1.51 mm could not be predicted accurately. Furthermore these correlations were based on data at low Reynolds numbers (up to 13000) and low heat flux, so the use of them for SULTAN-JHR may be questionable. According to the authors’ knowledge, existing models of heat transfer

  1. Liquid metals pumping

    International Nuclear Information System (INIS)

    Le Frere, J.P.

    1984-01-01

    Pumps used to pump liquid metals depend on the liquid metal and on the type of application concerned. One deals more particularly with electromagnetic pumps, the main pumps used with mechanical pumps. To pump sodium in the nuclear field, these two types of pumps are used; the pumps of different circuits of Super Phenix are presented and described [fr

  2. Electrokinetic pump

    Science.gov (United States)

    Patel, Kamlesh D.

    2007-11-20

    A method for altering the surface properties of a particle bed. In application, the method pertains particularly to an electrokinetic pump configuration where nanoparticles are bonded to the surface of the stationary phase to alter the surface properties of the stationary phase including the surface area and/or the zeta potential and thus improve the efficiency and operating range of these pumps. By functionalizing the nanoparticles to change the zeta potential the electrokinetic pump is rendered capable of operating with working fluids having pH values that can range from 2-10 generally and acidic working fluids in particular. For applications in which the pump is intended to handle highly acidic solutions latex nanoparticles that are quaternary amine functionalized can be used.

  3. Nuclear-pumped lasers

    CERN Document Server

    Prelas, Mark

    2016-01-01

    This book focuses on Nuclear-Pumped Laser (NPL) technology and provides the reader with a fundamental understanding of NPLs, a review of research in the field, and exploration of large scale NPL system design and applications. Early chapters look at the fundamental properties of lasers, nuclear-pumping and nuclear reactions that may be used as drivers for nuclear-pumped lasers. The book goes on to explore the efficient transport of energy from the ionizing radiation to the laser medium and then the operational characteristics of existing nuclear-pumped lasers. Models based on Mathematica, explanations and a tutorial all assist the reader’s understanding of this technology. Later chapters consider the integration of the various systems involved in NPLs and the ways in which they can be used, including beyond the military agenda. As readers will discover, there are significant humanitarian applications for high energy/power lasers, such as deflecting asteroids, space propulsion, power transmission and mining....

  4. JET pump limiter

    International Nuclear Information System (INIS)

    Sonnenberg, K.; Deksnis, E.; Shaw, R.; Reiter, D.

    1988-01-01

    JET plans to install two pump limiter modules which can be used for belt-limiter, inner-wall and X-point discharges and, also, for 1-2s as the main limiter. A design is presented which is compatible with two diagnostic systems, and which allows partial removal of the pump limiter to provide access for remote-handling operations. The high heat-flux components are initially cooled during a pulse. Heat is removed between discharges by radiation and pressure contacts to a water-cooled support structure. The pumping edge will be made of annealed pyrolytic graphite. Exhaust efficiency has been estimated, for a 1-d edge model, using a Monte-Carlo calculation of neutral gas transport. When the pump limiter is operated together with other wall components we expect an efficiency of ≅ 5% (2.5 x 10 21 part/s). As a main limiter the efficiency increases to about 10%. (author)

  5. Modelling of capillary Z-pinch recombination pumping of boron extreme ultraviolet laser

    Czech Academy of Sciences Publication Activity Database

    Vrba, Pavel; Bobrova, N. A.; Sasorov, P. V.; Vrbová, M.; Hübner, Jakub

    2009-01-01

    Roč. 16, č. 7 (2009), 073105 1-073105 11 ISSN 1070-664X R&D Projects: GA ČR GA102/07/0275 Institutional research plan: CEZ:AV0Z20430508 Keywords : Boron * capillary * discharges (electric * laser ablation * optical pumping * plasma heating by laser * plasma kinetic theory * plasma magnetohydrodynamics * Z pinch Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 2.475, year: 2009 http://link.aip.org/link/? PHP /16/073105

  6. A phenomenological model for collisional coherence transfer in an optically pumped atomic system

    Energy Technology Data Exchange (ETDEWEB)

    Khanbekyan, K; Bevilaqua, G; Mariotti, E; Moi, L [Universita degli Studi di Siena, Siena, 53100 (Italy); Khanbekyan, A; Papoyan, A, E-mail: karen.khanbekyan@gmail.com [Institute for Physical Research, National Academy of Sciences, Ashtarak 2 (Armenia)

    2011-03-14

    We consider a dual {Lambda}-system under double laser excitation to investigate the possibility of indirect coherence transfer between atomic ground states through an excited state. The atomic system is excited by a frequency modulated pump laser and probed by a low-power cw laser. All the decoherence mechanisms are discussed and taken into account. Adjustment of parameters of the two radiations aimed at maximization of coherence transfer is addressed. The study can help to understand the phenomena as collisional transfer of coherence and can find application in the experimental realization of atomic sensors.

  7. Pumps and pump facilities. 2. ed.

    International Nuclear Information System (INIS)

    Bohl, W.; Bauerfeind, H.; Gutmann, G.; Leuschner, G.; Matthias, H.B.; Mengele, R.; Neumaier, R.; Vetter, G.; Wagner, W.

    1981-01-01

    This book deals with the common fundamental aspects of liquid pumps and gives an exemplary choice of the most important kinds of pumps. The scientific matter is dealt with by means of practical mathematical examples among other ways of presenting the matter. Survey of contents: Division on main operational data of pumps - pipe characteristics - pump characteristics - suction behaviour of the pumps - projecting and operation of rotary pumps - boiler feed pumps - reactor feed pumps - oscillating positive-displacement pumps - eccentric spiral pumps. (orig./GL) [de

  8. Modeling Change in Watershed Streamflow, Groundwater Recharge and Surface Water - Groundwater Interactions Due to Irrigation and Associated Diversions and Pumping

    Science.gov (United States)

    Essaid, H.; Caldwell, R. R.

    2015-12-01

    The impacts of irrigation and associated surface water (SW) diversions and groundwater (GW) pumping on instream flows, groundwater recharge and SW-GW interactions are being examined using a watershed-scale coupled SW-GW flow model. The U.S. Geological Survey (USGS) model GSFLOW (Markstrom et al., 2008), an integration of the USGS Precipitation-Runoff Modeling System (PRMS) and the Modular Ground-Water Flow Model (MODFLOW), is being utilized for this effort. Processes represented in this model include daily rain, snowfall, snowmelt, streamflow, surface runoff, interflow, infiltration, soil-zone evapotranspiration, and subsurface unsaturated and groundwater flow and evapotranspiration. The Upper Smith River watershed, an important agricultural and recreational area in west-central Montana, is being used as the basis for watershed climate, topography, hydrography, vegetation, soil properties as well as scenarios of irrigation and associated practices. The 640 square kilometer watershed area has been discretized into coincident 200 m by 200 m hydrologic response units (for climate and soil zone flow processes) and grid blocks (for unsaturated zone and GW flow processes). The subsurface GW system is discretized into 6 layers representing Quaternary alluvium, Tertiary sediments and bedrock. The model is being used to recreate natural, pre-development streamflows and GW conditions in the watershed. The results of this simulation are then compared to a simulation with flood and sprinkler irrigation supplied by SW diversion and GW pumping to examine the magnitude and timing of changes in streamflow, groundwater recharge and SW-GW interactions. Model results reproduce observed hydrologic responses to both natural climate variability and irrigation practices. Periodic irrigation creates increased evapotranspiration and GW recharge in cultivated areas of the watershed as well as SW-GW interactions that are more dynamic than under natural conditions.

  9. Flow measurements in a model centrifugal pump by 3-D PIV

    International Nuclear Information System (INIS)

    Yang, H; Xu, H R; Liu, C

    2012-01-01

    PIV (Particle Image Velocimetry), as an non-intrusive flow measurements technology, is widely used to investigate the flow fields in many areas. 3-D (three Dimensional) PIV has seldom been used to measure flow field in rotational impeller of centrifugal pump due to the difficulty of calibration in samll space. In this article, a specially manufactured water tank was used to perform the calibration for 3-D PIV measurement. The instantaneous absolute velocity in one impeller passage was obtained by merging of three sub zones and the relative velocity was acquired by velocity decomposition. The result shows that, when the pump runs at the condition of design flow rate, the radial component velocity W r appears a concave distribution except the condition of R=45 mm. With the increase of radius, the circumference location of the minimum radial component velocity W r moves from the pressure side to the suction side. At the same time, the tangential component velocity W θ on the suction side decreases gradually with the increase of radius, while the component on the pressure side increases gradually. The secondary flow in different radius section has also been shown. At last, the error of PIV measurements was analyzed, which shows that the test results are accurate and the measured data is reliable.

  10. Modelling the fluid structure interaction produced by a waterhammer during shutdown of high-pressure pumps

    International Nuclear Information System (INIS)

    Erath, W.; Nowotny, B.; Maetz, J.

    1999-01-01

    Measurements of an experiment in a pipe system with pump shutdown and valve closing have been performed in the nuclear power plant KRB II (Gundremmingen, Germany). Comparative calculations of fluid and structure including interaction show an excellent agreement with the measured results. Theory and implementation of the fluid structure interaction (FSI) and the results of the comparison are described. The following measurements have been compared with calculations: (1) experiments in Delft, Netherlands to analyse the FSI; and (2) experiment with pump shutdown and valve closing in the nuclear power plant KRB II has been performed. It turns out, that the consideration of the FSI is necessary for an exact calculation of 'soft' piping systems. It has significant application in current waterhammer problems. For example, water column closure, vapour collapse, check valve slamming continues to create waterhammers in the energy industry. An important consequence of the FSI is mostly a significant increase of the effective structural damping. This mitigates - so far in all KED's calculations the FSI has taken into account - an amplification of pipe movements due to pressure waves in resonance with structural eigenvalues. To investigate the integrity of pipe systems pipe stresses are calculated. Taking FSI into account they are reduced by 10-40% in the actual case. (orig.)

  11. An advanced CFD model to study the effect of non-condensable gas on cavitation in positive displacement pumps

    Directory of Open Access Journals (Sweden)

    Iannetti Aldo

    2015-09-01

    Full Text Available An advanced transient CFD model of a positive displacement reciprocating pump was created to study its behavior and performance in cavitating condition during the inlet stroke. The “full” cavitation model developed by Singhal et al. was utilized, and a sensitivity analysis test on two air mass fraction amounts (1.5 and 15 parts per million was carried out to study the influence of the dissolved air content in water on the cavitation phenomenon. The model was equipped with user defined functions to introduce the liquid compressibility, which stabilizes the simulation, and to handle the two-way coupling between the pressure field and the inlet valve lift history. Estimation of the performance is also presented in both cases.

  12. Effect of duration of the pause single-phase auto-reclosing on electro-power transmission capacitance

    Directory of Open Access Journals (Sweden)

    Krasil'nikova Tatyana

    2017-01-01

    Full Text Available This paper discusses the problem associated with accidents in the aerial line (AL ultra-high voltage (UHV due to its big length. In lines with a voltage of 500-1150 kV the overwhelming proportion of trips (98% is caused by single-phase short circuit (SPSC. A substantial portion (70% single-phase short circuits is erratic arc accidents which can be successfully eliminated in a high-speed auto-reclosing (HSAR or single-phase auto-reclosing (SPAR. Success single-phase auto-reclosing (SPAR at liquidation by single-phase short circuit (SPSC, on the one hand, is determined by the characteristics of the secondary arc current, and on the other hand the effectiveness of ways to reduce secondary arc current and recovery voltage development. The minimum dead time, at a HSAR it is usually taken as 0.5 s., at single-phase autoreclosing (SPAR it depends on the current value of the arc support is in the range of 0.5-3.0 s. The article shows high efficiency of use single-phase auto reclosing (SPAR at liquidation SPSC in a single-chain AL voltage of 500 kV, the dependence of the bandwidth of transmission in maintaining the dynamic stability from the length of the pause SPAR.

  13. Mathematical modelling of nonlinear thermal radiation effects on EMHD peristaltic pumping of viscoelastic dusty fluid through a porous medium duct

    Directory of Open Access Journals (Sweden)

    M.M. Bhatti

    2017-06-01

    Full Text Available Biologically-inspired propulsion systems are currently receiving significant interest in the aerospace sector. Since many spacecraft propulsion systems operate at high temperatures, thermal radiation is important as a mode of heat transfer. Motivated by these developments, in the present article, the influence of nonlinear thermal radiation (via the Rosseland diffusion flux model has been studied on the laminar, incompressible, dissipative EMHD (Electro-magneto-hydrodynamic peristaltic propulsive flow of a non-Newtonian (Jefferys viscoelastic dusty fluid containing solid particles through a porous planar channel. The fluid is electrically-conducting and a constant static magnetic field is applied transverse to the flow direction (channel walls. Slip effects are also included. Magnetic induction effects are neglected. The mathematical formulation is based on continuity, momentum and energy equations with appropriate boundary conditions, which are simplified by neglecting the inertial forces and taking the long wavelength and lubrication approximations. The boundary value problem is then rendered non-dimensional with appropriate variables and the resulting system of reduced ordinary differential equations is solved analytically. The impact of various emerging parameters dictating the non-Newtonian propulsive flow i.e. Prandtl number, radiation parameter, Hartmann number, permeability parameter, Eckert number, particle volume fraction, electric field and slip parameter are depicted graphically. Increasing particle volume fraction is observed to suppress temperature magnitudes. Furthermore the computations demonstrate that an increase in particle volume fraction reduces the pumping rate in retrograde pumping region whereas it causes the opposite effect in the co-pumping region. The trapping mechanism is also visualized with the aid of streamline contour plots. Increasing thermal radiation elevates temperatures. Increasing Hartmann (magnetic body

  14. High Performance Harmonic Isolation By Means of The Single-phase Series Active Filter Employing The Waveform Reconstruction Method

    DEFF Research Database (Denmark)

    Senturk, Osman Selcuk; Hava, Ahmet M.

    2009-01-01

    This paper proposes the Waveform Reconstruction Method (WRM), which is utilized in the single-phase Series Active Filter's (SAF's) control algorithm, in order to extract the load harmonic voltage component of voltage harmonic type single-phase diode rectifier loads. Employing WRM and the line...... current sampling delay reduction method (SDRM), a single-phase SAF compensated system provides higher harmonic isolation performance and higher stability margins compared to the system using conventional synchronous reference frame based methods. The analytical, simulation, and experimental studies of a 2...

  15. Fabrication of single phase 2D homologous perovskite microplates by mechanical exfoliation

    Science.gov (United States)

    Li, Junze; Wang, Jun; Zhang, Yingjun; Wang, Haizhen; Lin, Gaoming; Xiong, Xuan; Zhou, Weihang; Luo, Hongmei; Li, Dehui

    2018-04-01

    The two-dimensional (2D) Ruddlesden-Popper type perovskites have attracted intensive interest for their great environmental stability and various potential optoelectronic applications. Fundamental understanding of the photophysical and electronic properties of the 2D perovskites with pure single phase is essential for improving the performance of the optoelectronic devices and designing devices with new architectures. Investigating the optical and electronic properties of these materials with pure single phase is required to obtain pure single phase 2D perovskites. Here, we report on an alternative approach to fabricate (C4H9NH3)2(CH3NH3) n-1Pb n I3n+1 microplates with pure single n-number perovskite phase for n  >  2 by mechanical exfoliation. Micro-photoluminescence and absorption spectroscopy studies reveal that the as-synthesized 2D perovskite plates for n  >  2 are comprised by dominant n-number phase and small inclusions of hybrid perovskite phases with different n values, which is supported by excitation power dependent photoluminescence. By mechanical exfoliation method, 2D perovskite microplates with the thickness of around 20 nm are obtained, which surprisingly have single n-number perovskite phase for n  =  2-5. In addition, we have demonstrated that the exfoliated 2D perovskite microplates can be integrated with other 2D layered materials such as boron nitride, and are able to be transferred to prefabricated electrodes for photodetections. Our studies not only provide a strategy to prepare 2D perovskites with a single n-number perovskite phase allowing us to extract the basic optical and electronic parameters of pure phase perovskites, but also demonstrate the possibility to integrate the 2D perovskites with other 2D layered materials to extend the device’s functionalities.

  16. Reliable Grid Condition Detection and Control of Single-Phase Distributed Power Generation Systems

    DEFF Research Database (Denmark)

    Ciobotaru, Mihai

    to the utility grid but also to sustain it. This thesis was divided into two main parts, namely "Grid Condition Detection" and "Control of Single-Phase DPGS". In the first part, the main focus was on reliable Phase Locked Loop (PLL) techniques for monitoring the grid voltage and on grid impedance estimation...... of the entire system. Regarding the advance control of DPGS, an active damping technique for grid-connected systems using inductor-capacitorinductor (LCL) filters was proposed in the thesis. The method is based on a notch filter, whose stopband can be automatically adjusted in relation with an estimated value...

  17. Power quality improvement of single-phase photovoltaic systems through a robust synchronization method

    DEFF Research Database (Denmark)

    Hadjidemetriou, Lenos; Kyriakides, Elias; Yang, Yongheng

    2014-01-01

    An increasing amount of single-phase photovoltaic (PV) systems on the distribution network requires more advanced synchronization methods in order to meet the grid codes with respect to power quality and fault ride through capability. The response of the synchronization technique selected...... to the harmonic voltage distortion without affecting the dynamic response of the synchronization. Therefore, the accurate response of the proposed MHDC-PLL enhances the power quality of the PV inverter systems and additionally, the proper fault ride-through operation of PV systems can be enabled by the fast...

  18. Pressure drop and heat transfer of lithium single-phase flow under transverse magnetic field

    International Nuclear Information System (INIS)

    Takahashi, Minoru; Aritomi, Masanori; Inoue, Akira; Matsuzaki, Mitsuo

    1996-01-01

    Pressure drop and heat transfer characteristics of a lithium single-phase flow in a rectangular channel was investigated experimentally in the presence of a magnetic field. Friction loss coefficient under non-magnetic field and skin friction coefficient under magnetic field agreed well with the Blasius formula and a simple analytical expression, respectively. Nusselt number under non-magnetic field was slightly lower than the correlation by Hartnett and Irvine. Heat transfer was enhanced by increasing magnetic field above the Hartmann number of about 200. (author)

  19. An LLCL Power Filter for Single-Phase Grid-Tied Inverter

    DEFF Research Database (Denmark)

    Wu, Weimin; He, Yuanbin; Blaabjerg, Frede

    2012-01-01

    This paper presents a new topology of higher order power filter for grid-tied voltage-source inverters, named the LLCL filter, which inserts a small inductor in the branch loop of the capacitor in the traditional LCL filter to compose a series resonant circuit at the switching frequency...... to the inverter system control. The parameter design criteria of the proposed LLCL filter is also introduced. The comparative analysis and discussions regarding the traditional LCL filter and the proposed LLCL filter have been presented and evaluated through experiment on a 1.8-kW-single-phase grid-tied inverter...

  20. A MPPT Algorithm Based PV System Connected to Single Phase Voltage Controlled Grid

    Science.gov (United States)

    Sreekanth, G.; Narender Reddy, N.; Durga Prasad, A.; Nagendrababu, V.

    2012-10-01

    Future ancillary services provided by photovoltaic (PV) systems could facilitate their penetration in power systems. In addition, low-power PV systems can be designed to improve the power quality. This paper presents a single-phase PV systemthat provides grid voltage support and compensation of harmonic distortion at the point of common coupling thanks to a repetitive controller. The power provided by the PV panels is controlled by a Maximum Power Point Tracking algorithm based on the incremental conductance method specifically modified to control the phase of the PV inverter voltage. Simulation and experimental results validate the presented solution.

  1. A control strategy for induction motors fed from single phase supply

    DEFF Research Database (Denmark)

    Søndergård, Lars Møller

    1993-01-01

    It is often required that a three-phased asynchronous motor can run at variable speed, which makes it necessary to use a three-phase inverter driven from a DC-source. Today, most inverters are driven from the network using a simple diode bridge and an electrolytic capacitor. The problem...... with the simple diode bridge and the electrolytic capacitor is that current is only drawn for short periods, which gives rise to harmonic currents in the network. For small drive systems (motor+inverter), i.e. less than 1.5 kW, a single phase network outlet is often used. The author describes a method whereby...

  2. Novel Position and Speed Estimator for PM Single Phase Brushless D.C. Motor Drives

    DEFF Research Database (Denmark)

    Lepure, Liviu I.; Andreescu, Gheorghe-Daniel; Iles, Doris

    2010-01-01

    A novel position and speed estimator for single phase permanent magnet brushless d.c. (PMBLDC) motor drives, based on flux integration and prior knowledge of ΨPM (θ) is proposed here and an adequate correction algorithm is adopted in order to increase the robustness to noise and to reduce...... the sensitivity to accuracy of flux linkage estimation. A speed and current close loop control is employed based on the Hall signal and the motor is controlled at different speeds in order to validate the proposed estimation algorithm with satisfying results. The position correction effect is analyzed...

  3. Single Phase Transformer-less Buck-Boost Inverter with Zero Leakage Current for PV Systems

    DEFF Research Database (Denmark)

    Mostaan, Ali; Abdelhakim, Ahmed; N. Soltani, Mohsen

    2017-01-01

    In this paper, a novel single-stage single-phase transformer-less buck-boost inverter is proposed, in which a reduced number of passive components is used. The proposed inverter combines the conventional buck, boost, and buck-boost converters in one converter in order to obtain a sinusoidal output...... voltage. In the proposed inverter, the input DC source and the load or grid have the same ground. Therefore, the leakage current problem in photovoltaic (PV) systems is eliminated. Furthermore, the proposed inverter supports the bi-directional power flow capability and it can inject reactive power...

  4. Single phase and two-phase flow pressure losses through restrictions, expansions and inserts

    International Nuclear Information System (INIS)

    Glenat, P.; Solignac, P.

    1984-11-01

    We give a selection of methods to predict pressure losses through retrictions, expansions and inserts. In single phase flow, we give the classical method based on the one-dimensional momentum and mass balances. In two-phase flow, we propose the method given by Harshe et al. and an empirical approach suggested by Chisholm. We notice the distinction between long and short inserts depends upon wether or not the vena contracta lies within insert. Finally, we propose three correlations to calculate void fraction through the singularities which have been considered [fr

  5. A low capacitance single-phase AC-DC converter with inherent power ripple decoupling

    OpenAIRE

    Gottardo, Davide; De Lillo, Liliana; Empringham, Lee; Costabeber, Alessando

    2016-01-01

    This paper proposes a new single-phase AC-DC conversion topology with inherent power ripple decoupling, based on the combination of a PWM H-bridge inverter, an AC side LC filter and a ZVS line commutated H-bridge. A capacitor on the AC side is used as power decoupling element. By appropriate selection of the capacitor voltage, the power ripple at twice the AC frequency can be cancelled from the DC side instantaneous power, achieving negligible DC voltage ripple using a smaller total capacitan...

  6. Dynamics Assessment of Grid-Synchronization Algorithms for Single-Phase Grid-Connected Converters

    DEFF Research Database (Denmark)

    Han, Yang; Luo, Mingyu; Guerrero, Josep M.

    2015-01-01

    and low computational burden. Meanwhile, some other techniques have been proposed to enhance system robustness and stability characteristics. In this paper, a comprehensive comparison among the OSG-based PLLs and the advanced single-phase PLLs is presented when the grid voltage undergoes disturbances......, and the performance comparison of transient response and disturbance rejection capabilities are presented. Finally, the moving average filter (MAF) is applied to enhance steady state and dynamic response of the delayed-type PLL, derivator-based PLL and the complex-coefficient filter (CCF-PLL) under grid frequency...

  7. A new type of single-phase five-level inverter

    Science.gov (United States)

    Xu, Zhi; Li, Shengnan; Qin, Risheng; Zhao, Yanhang

    2017-11-01

    At present, Neutral Point Clamped (NPC) multilevel inverter is widely applied in new energy field. However, it has some disadvantages including low utilization rate of direct current (DC) voltage source and the unbalance of neutral potential. Therefore, a new single-phase five level inverter is proposed in this paper. It has two stage structure, the former stage is equivalent to three level DC/DC converter, and the back stage uses H bridge to realize inverter. Compared with the original central clamp type inverter, the new five level inverter can improve the utilization of DC voltage, and realize the neutral point potential balance with hysteresis comparator.

  8. Dispersed single-phase-step Michelson interferometer for Doppler imaging using sunlight.

    Science.gov (United States)

    Wan, Xiaoke; Ge, Jian

    2012-09-15

    A Michelson interferometer is dispersed with a fiber array-fed spectrograph, providing 59 Doppler sensing channels using sunlight in the 510-570 nm wavelength region. The interferometer operates at a single-phase-step mode, which is particularly advantageous in multiplexing and data processing compared to the phase-stepping mode of other interferometer spectrometer instruments. Spectral templates are prepared using a standard solar spectrum and simulated interferometer modulations, such that the correlation function with a measured 1D spectrum determines the Doppler shift. Doppler imaging of a rotating cylinder is demonstrated. The average Doppler sensitivity is ~12 m/s, with some channels reaching ~5 m/s.

  9. Modelling the erosion/deposition pattern of the Tore Supra Toroidal Pumped Limiter

    International Nuclear Information System (INIS)

    Panayotis, S.; Pégourié, B.; Borodin, D.; Kirschner, A.; Gunn, J.; Marandet, Y.; Mellet, N.

    2015-01-01

    This paper aims at understanding the main processes responsible for the erosion/deposition pattern observed on the surface of the Toroidal Pumped Limiter of Tore Supra, using the 3D local impurity transport code ERO. The influence of the plasma impurity content, CX-flux and surface temperature on the global carbon balance and erosion/deposition pattern is discussed. Main results are (1) that considering medium-range transport of C ions is mandatory for reproducing the main characteristics of the global C balance and erosion/deposition pattern, (2) that impurities and CX-atoms increase the erosion by a factor ⩽2 (without changing the net/gross erosion ratio), and (3) that chemical erosion is governed by the re-erosion of deposits, which depends strongly on the surface temperature

  10. Scavenged body heat powered infusion pump

    International Nuclear Information System (INIS)

    Bell, Alexander; Ehringer, William D; McNamara, Shamus

    2013-01-01

    An infusion pump powered by body heat is investigated in this paper, with the goal of addressing the needs of dermal wound healing. The infusion pump incorporates a Knudsen gas pump, a type of thermally driven pump, to pneumatic push the pharmaceutical agent from a reservoir. Two designs are considered: an integrated pump and reservoir, and a design with cascaded pump and reservoir. Thermal models are developed for both pumps, and the simulations agree well with the experimental results. The integrated pump and reservoir design uses hydrophobic materials to prevent a flow from occurring unless the infusion pump is placed on a human body. Flow rates in the µL min −1 range for the integrated pump and reservoir, and approximately 70 µL min −1 for the cascaded pump were obtained. The dynamic behavior of the cascaded pump is described based on the thermal models. Multiple copies of the cascaded pump are easily made in series or parallel, to increase either the pressure or the flow rate. The flow rate of multiple pumps in series does not change, and the pressure of multiple pumps in parallel does not change. (paper)

  11. Theoretical modelling of dual-wavelength pumped Yb3+–Tm3+ co-doped silica fibre laser

    International Nuclear Information System (INIS)

    Fu, Yuqing; Chen, Jianguo

    2010-01-01

    Numerical simulations have, for the first time to our knowledge, been carried out to characterize the Yb 3+ –Tm 3+ co-doped silica fibre laser (YTFL), defined by a fibre grating and an end mirror, by using the rate equations, which take into consideration both the energy transfer processes from Yb 3+ to Tm 3+ ions and the cross-relaxation processes among different Tm 3+ ions. A dual-wavelength pumping scheme with one at 805 nm and the other at 975 nm is used to pump the YTFL. We have investigated the wavelength-dependent output power of the YTFL, from 1750 to 2200 nm, which takes its maximum output power at ∼ 1800 nm. The effect of the cross-relaxation processes in the Tm 3+ -doped silica fibre laser has been studied. The results indicate that these processes are beneficial to the laser and should be considered in the theoretical modelling. The influence of the Yb 3+ concentration on the characteristics of the YTFL has also been analysed and the results show that Yb 3+ dopants can improve the output power and slope efficiency of the laser

  12. Implementation of Wolsong Pump Model, Pressure Tube Deformation Model and Off-take Model into MARS Code for Regulatory Auditing of CANDU Reactors

    International Nuclear Information System (INIS)

    Yoon, C.; Rhee, B. W.; Chung, B. D.; Cho, Y. J.; Kim, M. W.

    2008-01-01

    Korea currently has four operating units of the CANDU-6 type reactor in Wolsong. However, the safety assessment system for CANDU reactors has not been fully established due to lack of self-reliance technology. Although the CATHENA code had been introduced from AECL, it is undesirable to use vendor's code for regulatory auditing analysis. In Korea, the MARS code has been developed for decades and is being considered by KINS as a thermal hydraulic regulatory auditing tool for nuclear power plants. Before this decision, KINS (Korea Institute of Nuclear Safety) had developed RELAP5/MOD3/CANDU code for CANDU safety analyses by modifying the model of existing PWR auditing tool, RELAP5/MOD3. The main purpose of this study is to transplant the CANDU models of RELAP5/MOD3/CANDU code to MARS code including quality assurance of the developed models. This first part of the research series presents the implementation and verification of the Wolsong pump model, the pressure tube deformation model, and the off-take model for arbitrary-angled branch pipes

  13. Application of a compressible flow solver and barotropic cavitation model for the evaluation of the suction head in a low specific speed centrifugal pump impeller channel

    International Nuclear Information System (INIS)

    Limbach, P; Müller, T; Skoda, R

    2015-01-01

    Commonly, for the simulation of cavitation in centrifugal pumps incompressible flow solvers with VOF kind cavitation models are applied. Since the source/sink terms of the void fraction transport equation are based on simplified bubble dynamics, empirical parameters may need to be adjusted to the particular pump operating point. In the present study a barotropic cavitation model, which is based solely on thermodynamic fluid properties and does not include any empirical parameters, is applied on a single flow channel of a pump impeller in combination with a time-explicit viscous compressible flow solver. The suction head curves (head drop) are compared to the results of an incompressible implicit standard industrial CFD tool and are predicted qualitatively correct by the barotropic model. (paper)

  14. Application of a compressible flow solver and barotropic cavitation model for the evaluation of the suction head in a low specific speed centrifugal pump impeller channel

    Science.gov (United States)

    Limbach, P.; Müller, T.; Skoda, R.

    2015-12-01

    Commonly, for the simulation of cavitation in centrifugal pumps incompressible flow solvers with VOF kind cavitation models are applied. Since the source/sink terms of the void fraction transport equation are based on simplified bubble dynamics, empirical parameters may need to be adjusted to the particular pump operating point. In the present study a barotropic cavitation model, which is based solely on thermodynamic fluid properties and does not include any empirical parameters, is applied on a single flow channel of a pump impeller in combination with a time-explicit viscous compressible flow solver. The suction head curves (head drop) are compared to the results of an incompressible implicit standard industrial CFD tool and are predicted qualitatively correct by the barotropic model.

  15. Novel Family of Single-Phase Modified Impedance-Source Buck-Boost Multilevel Inverters with Reduced Switch Count

    DEFF Research Database (Denmark)

    Husev, Oleksandr; Strzelecki, Ryszard; Blaabjerg, Frede

    2016-01-01

    This paper describes novel single-phase solutions with increased inverter voltage levels derived by means of a nonstandard inverter configuration and impedance source networks. Operation principles based on special modulation techniques are presented. Detailed component design guidelines along wi...

  16. A model predictive framework of Ground Source Heat Pump coupled with Aquifer Thermal Energy Storage System in heating and cooling equipment of a building

    NARCIS (Netherlands)

    Rostampour Samarin, V.; Bloemendal, J.M.; Keviczky, T.

    2017-01-01

    This paper presents a complete model of a building heating and cooling equipment and a ground source heat pump (GSHP) coupled with an aquifer thermal energy storage (ATES) system. This model contains detailed
    mathematical representations of building thermal dynamics, ATES system dynamics, heat

  17. A Nonadaptive Window-Based PLL for Single-Phase Applications

    DEFF Research Database (Denmark)

    Golestan, Saeed; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

    2018-01-01

    The rectangular window filter, typically known as the moving average filter (MAF), is a quasi-ideal low-pass filter that has found wide application in designing advanced single-phase phase-locked loops (PLLs). Most often, the MAF is employed as an in-loop filter within the control loop of the sin......The rectangular window filter, typically known as the moving average filter (MAF), is a quasi-ideal low-pass filter that has found wide application in designing advanced single-phase phase-locked loops (PLLs). Most often, the MAF is employed as an in-loop filter within the control loop...... response is avoided. Nevertheless, the PLL implementation complexity considerably increases as MAFs are frequency-adaptive and, therefore, they require an additional frequency detector for estimating the grid frequency. To reduce the implementation complexity while maintaining a good performance, using...... a nonadaptive MAF-based QSG with some error compensators is suggested in this letter. The effectiveness of the resultant PLL, which is briefly called the nonadaptive MAF-based PLL, is verified using experimental results....

  18. Ion beam induced single phase nanocrystalline TiO{sub 2} formation

    Energy Technology Data Exchange (ETDEWEB)

    Rukade, Deepti A. [Department of Physics, University of Mumbai, Mumbai 400098 (India); Tribedi, L.C. [Tata Institute of Fundamental Research, Homi Bhabha Road, Colaba, Mumbai 400005 (India); Bhattacharyya, Varsha, E-mail: varsha.b1.physics@gmail.com [Department of Physics, University of Mumbai, Mumbai 400098 (India)

    2014-06-15

    Single phase TiO{sub 2} nanostructures are fabricated by oxygen ion implantation (60 keV) at fluence ranging from 1×10{sup 16} ions/cm{sup 2} to 1×10{sup 17} ions/cm{sup 2} in titanium thin films deposited on fused silica substrate and subsequent thermal annealing in argon atmosphere. GAXRD and Raman spectroscopy study reveals formation of single rutile phases of TiO{sub 2}. Particle size is found to vary from 29 nm to 35 nm, establishing nanostructure formation. Nanostructure formation is also confirmed by the quantum confinement effect manifested by the blueshift of the UV–vis absorption spectra. Photoluminescence spectra show peaks corresponding to TiO{sub 2} rutile phase and reveal the presence of oxygen defects due to implantation. The controlled synthesis of single phase nanostructure is attributed to ion induced defects and post-implantation annealing. It is observed that the size of the nanostructures formed is strongly dependent on the ion fluence.

  19. FUZZY LOGIC BASED OPTIMIZATION OF CAPACITOR VALUE FOR SINGLE PHASE OPEN WELL SUBMERSIBLE INDUCTION MOTOR

    Directory of Open Access Journals (Sweden)

    R. Subramanian

    2011-01-01

    Full Text Available Purpose – The aim of this paper is to optimize the capacitor value of a single phase open well submersible motor operating under extreme voltage conditions using fuzzy logic optimization technique and compared with no-load volt-ampere method. This is done by keeping the displacement angle (a between main winding and auxiliary winding near 90o, phase angle (f between the supply voltage and line current near 0o. The optimization work is carried out by using Fuzzy Logic Toolbox software built on the MATLAB technical computing environment with Simulink software. Findings – The optimum capacitor value obtained is used with a motor and tested for different supply voltage conditions. The vector diagrams obtained from the experimental test results indicates that the performance is improved from the existing value. Originality/value – This method will be highly useful for the practicing design engineers in selecting the optimum capacitance value for single phase induction motors to achieve the best performance for operating at extreme supply voltage conditions.

  20. Simplified thermal-hydraulic analysis of single phase natural circulation circuit with two heat exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Pinheiro, Larissa Cunha; Su, Jian, E-mail: larissa@lasme.coppe.ufrj.br, E-mail: sujian@lasme.coppe.ufrj.br [Coordenacao dos Programas de Pos-Graduacao em Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenhraria Nuclear; Cotta, Renato Machado, E-mail: cotta@mecanica.coppe.ufrj.br [Coordenacao dos Programas de Pos-Graduacao em Engenharia (POLI/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Dept. de Engenharia Mecanica

    2015-07-01

    Single phase natural circulation circuits composed of two convective heat exchangers and connecting tubes are important for the passive heat removal from spent fuel pools (SFP). To keep the structural integrity of the stored spent fuel assemblies, continuously cooling has to be provided in order to avoid increase at the pool temperature and subsequent uncovering of the fuel and enhanced reaction between water and metal releasing hydrogen. Decay heat can achieve considerably high amounts of energy e.g. in the AP1000, considering the emergency fuel assemblies, the maximum heat decay will reach 13 MW in the 15th day (Westinghouse Electric Company, 2010). A highly efficient alternative to do so is by means of natural circulation, which is cost-effective compared to active cooling systems and is inherently safer since presents less associated devices and no external work is required. Many researchers have investigated safety and stability aspects of natural circulation loops (NCL). However, there is a lack of literature concerning the improvement of NCL through a standard unified methodology, especially for natural circulation circuits with two heat exchangers. In the present study, a simplified thermal-hydraulic analysis of single phase natural circulation circuit with two heat exchanges is presented. Relevant dimensionless key groups were proposed to for the design and safety analysis of a scaled NCL for the cooling of spent fuel storage pool with convective cooling and heating. (author)

  1. New saliva secretion model based on the expression of Na+-K+ pump and K+ channels in the apical membrane of parotid acinar cells.

    Science.gov (United States)

    Almássy, János; Siguenza, Elias; Skaliczki, Marianna; Matesz, Klara; Sneyd, James; Yule, David I; Nánási, Péter P

    2018-04-01

    The plasma membrane of parotid acinar cells is functionally divided into apical and basolateral regions. According to the current model, fluid secretion is driven by transepithelial ion gradient, which facilitates water movement by osmosis into the acinar lumen from the interstitium. The osmotic gradient is created by the apical Cl - efflux and the subsequent paracellular Na + transport. In this model, the Na + -K + pump is located exclusively in the basolateral membrane and has essential role in salivary secretion, since the driving force for Cl - transport via basolateral Na + -K + -2Cl - cotransport is generated by the Na + -K + pump. In addition, the continuous electrochemical gradient for Cl - flow during acinar cell stimulation is maintained by the basolateral K + efflux. However, using a combination of single-cell electrophysiology and Ca 2+ -imaging, we demonstrate that photolysis of Ca 2+ close to the apical membrane of parotid acinar cells triggered significant K + current, indicating that a substantial amount of K + is secreted into the lumen during stimulation. Nevertheless, the K + content of the primary saliva is relatively low, suggesting that K + might be reabsorbed through the apical membrane. Therefore, we investigated the localization of Na + -K + pumps in acinar cells. We show that the pumps appear evenly distributed throughout the whole plasma membrane, including the apical pole of the cell. Based on these results, a new mathematical model of salivary fluid secretion is presented, where the pump reabsorbs K + from and secretes Na + to the lumen, which can partially supplement the paracellular Na + pathway.

  2. Optimum pump armament in supply networks; Optimal pumpebestykning i forsynignssystemer

    Energy Technology Data Exchange (ETDEWEB)

    Kristjansson, Halldor

    2005-06-15

    The report presents recommendations as regards pump armament in district heating pump centres and the linked savings. A model has been built which shows variations of efficiency for motor and pump. (BA)

  3. Influence of absorbed pump profile on the temperature distribution ...

    Indian Academy of Sciences (India)

    2017-01-20

    -pumped laser rod is extracted. This model can be used for side-pumped laser rods whose absorbed pump profile is a Gaussian profile. Then, it is validated by numerical results which exhibit a good agreement with the ...

  4. Development and validation of single-phase and three-phase transformer models with saturation for the analysis of harmonics in electrical power systems; Desarrollo y validacion de modelos de transformadores monofasicos y trifasicos con saturacion, para el analisis de armonicos en sistemas electricos de potencia

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Garcia, Ricardo

    2000-11-01

    This work allowed to develop a modeling of the transformer with saturation of the magnetic core focussed to the analysis of flows with harmonics. An experimental study was performed in three laboratories, the laboratory of the Department of Electrical Engineering of the Polytechnic University of Cataluna, and two laboratories of manufacturers of electrical equipment, SALICRV and MIMAVEN. The program of Pspice simulation was used to make the model of the experimental study allowing with it the validation of the developed model against the laboratory tests. [Spanish] Este trabajo permitio desarrollar una modelacion del transformador con saturacion del nucleo magnetico enfocado para el analisis de flujos con armonicos. Se realizo un estudio experimental en tres laboratorios, el laboratorio de el Departamento de Ingenieria Electrica de la Universidad Politecnica de Cataluna, y dos laboratorios de fabricantes de equipos electricos, SALICRV y MIMAVEN. Se utilizo el programa de simulacion Pspice para realizar la modelacion del estudio experimental permitiendo con ello la validacion del modelo desarrollado contra los ensayos de laboratorio.

  5. BLENDING STUDY FOR SRR SALT DISPOSITION INTEGRATION: TANK 50H SCALE-MODELING AND COMPUTER-MODELING FOR BLENDING PUMP DESIGN, PHASE 2

    Energy Technology Data Exchange (ETDEWEB)

    Leishear, R.; Poirier, M.; Fowley, M.

    2011-05-26

    The Salt Disposition Integration (SDI) portfolio of projects provides the infrastructure within existing Liquid Waste facilities to support the startup and long term operation of the Salt Waste Processing Facility (SWPF). Within SDI, the Blend and Feed Project will equip existing waste tanks in the Tank Farms to serve as Blend Tanks where 300,000-800,000 gallons of salt solution will be blended in 1.3 million gallon tanks and qualified for use as feedstock for SWPF. Blending requires the miscible salt solutions from potentially multiple source tanks per batch to be well mixed without disturbing settled sludge solids that may be present in a Blend Tank. Disturbing solids may be problematic both from a feed quality perspective as well as from a process safety perspective where hydrogen release from the sludge is a potential flammability concern. To develop the necessary technical basis for the design and operation of blending equipment, Savannah River National Laboratory (SRNL) completed scaled blending and transfer pump tests and computational fluid dynamics (CFD) modeling. A 94 inch diameter pilot-scale blending tank, including tank internals such as the blending pump, transfer pump, removable cooling coils, and center column, were used in this research. The test tank represents a 1/10.85 scaled version of an 85 foot diameter, Type IIIA, nuclear waste tank that may be typical of Blend Tanks used in SDI. Specifically, Tank 50 was selected as the tank to be modeled per the SRR, Project Engineering Manager. SRNL blending tests investigated various fixed position, non-rotating, dual nozzle pump designs, including a blending pump model provided by the blend pump vendor, Curtiss Wright (CW). Primary research goals were to assess blending times and to evaluate incipient sludge disturbance for waste tanks. Incipient sludge disturbance was defined by SRR and SRNL as minor blending of settled sludge from the tank bottom into suspension due to blending pump operation, where

  6. An Experimental Facility to Validate Ground Source Heat Pump Optimisation Models for the Australian Climate

    Directory of Open Access Journals (Sweden)

    Yuanshen Lu

    2017-01-01

    Full Text Available Ground source heat pumps (GSHPs are one of the most widespread forms of geothermal energy technology. They utilise the near-constant temperature of the ground below the frost line to achieve energy-efficiencies two or three times that of conventional air-conditioners, consequently allowing a significant offset in electricity demand for space heating and cooling. Relatively mature GSHP markets are established in Europe and North America. GSHP implementation in Australia, however, is limited, due to high capital price, uncertainties regarding optimum designs for the Australian climate, and limited consumer confidence in the technology. Existing GSHP design standards developed in the Northern Hemisphere are likely to lead to suboptimal performance in Australia where demand might be much more cooling-dominated. There is an urgent need to develop Australia’s own GSHP system optimisation principles on top of the industry standards to provide confidence to bring the GSHP market out of its infancy. To assist in this, the Queensland Geothermal Energy Centre of Excellence (QGECE has commissioned a fully instrumented GSHP experimental facility in Gatton, Australia, as a publically-accessible demonstration of the technology and a platform for systematic studies of GSHPs, including optimisation of design and operations. This paper presents a brief review on current GSHP use in Australia, the technical details of the Gatton GSHP facility, and an analysis on the observed cooling performance of this facility to date.

  7. Thermal Impact Assessment of Groundwater Heat Pumps (GWHPs: Rigorous vs. Simplified Models

    Directory of Open Access Journals (Sweden)

    Bruno Piga

    2017-09-01

    Full Text Available Groundwater Heat Pumps (GWHPs are increasingly adopted for air conditioning in urban areas, thus reducing CO2 emissions, and this growth needs to be managed to ensure the sustainability of the thermal alteration of aquifers. However, few studies have addressed the propagation of thermal plumes from open-loop geothermal systems from a long-term perspective. We provide a comprehensive sensitivity analysis, performed with numerical finite-element simulations, to assess how the size of the thermally affected zone is driven by hydrodynamic and thermal subsurface properties, the vadose zone and aquifer thickness, and plant setup. In particular, we focus the analysis on the length and width of thermal plumes, and on their time evolution. Numerical simulations are compared with two simplified methods, namely (i replacing the time-varying thermal load with its yearly average and (ii analytical formulae for advective heat transport in the aquifer. The former proves acceptable for the assessment of plume length, while the latter can be used to estimate the width of the thermally affected zone. The results highlight the strong influence of groundwater velocity on the plume size and, especially for its long-term evolution, of ground thermal properties and of subsurface geometrical parameters.

  8. An exsolution silica-pump model for the origin of myrmekite

    Science.gov (United States)

    Castle, R.O.; Lindsley, D.H.

    1993-01-01

    Myrmekite, as defined here, is the microscopic intergrowth between vermicular quartz and modestly anorthitic plagioclase (calcic albite-oligoclase), intimately associated with potassium feldspar in plutonic rocks of granitic composition. Hypotheses previously invoked in explanation of myrmekite include: (1) direct crystallization; (2) replacement; (3) exsolution. The occurrence of myrmekite in paragneisses and its absence in rocks devold of discrete grains of potassium feldspar challenge those hypotheses based on direct crystallization or replacement. However, several lines of evidence indicate that myrmekite may in fact originate in response to kinetic effects associated with the exsolution of calcic alkali feldspar into discrete potassium feldspar and plagioclase phases. Exsolution of potassium feldspar system projected from [AlSi2O8] involves the exchange CaAlK-1Si-1, in which the AlSi-1 tetrahedral couple is resistant to intracrystalline diffusion. By contrast, diffusion of octahedral K proceeds relatively easily where it remains uncoupled to the tetrahedral exchange. We suggest here that where the ternary feldspar system is open to excess silica, the exchange reaction that produces potassium feldspar in the ternary plane is aided by the net-transfer reaction K+Si=Orthoclase, leaving behind indigenous Si that reports as modal quartz in the evolving plagioclase as the CaAl component is concomitantly incorporated in this same phase. Thus silica is "pumped" into the reaction volume from a "silica reservoir", a process that enhances redistribution of both Si and Al through the exsolving ternary feldspar. ?? 1993 Springer-Verlag.

  9. Comparative study of models of the recirculation loop with 10 jet pumps using different components in the code RELAP5/SCDAPSIM Mod.3.4

    International Nuclear Information System (INIS)

    Araiza M, E.; Ortiz V, J.

    2012-10-01

    This work presents two arrangements in the nodal analysis of a recirculation loop for a BWR. Each one of these arrangements includes the ten jet pumps in each loop, instead of the traditional arrangement that consist of only jet pump representing to the ten pumps of a loop. The difference among the two models is presented mainly in the nodal analysis of the connection type cross-reduction, which takes charge of distributing the coolant flow to the lateral head stocks, where the vertical pipes (risers) that send the flow toward the jet pumps are connected. In the first arrangement the cross-reduction is modeled using the Branch component that is used in the interconnections simulation of hydrodynamic components. In the second arrangement the cross is simulated connecting the two distributor lateral head stocks with the main pipe of the loop by means of two simple unions that are modeled with the component SNGLJUN. The obtained results of the execution of both models are compared, taking important variables as reference, like pressures and mass expenses for the same components of both models. Finally these results are compared with the proportionate results by the traditional model. (Author)

  10. Sizing modelling and simulation of PV generation system feeding a 6 MW induction motor dedicated to pumping applications

    Directory of Open Access Journals (Sweden)

    Samir HADJERI

    2017-06-01

    Full Text Available This paper proposes an autonomous photovoltaic (PV pumping system for rural/remote applications especially in the large desert in northern Africa where the sun radiation is abundant. Since PV generators exhibit nonlinear I-V characteristics and their maximum power point varies with solar radiation. For this reason, the MPPT controller is used to optimize the solar energy conversion by guaranteeing fast maximum power point tracking (MPPT. This feature has an essential role in dynamic response and efficiency of the photovoltaic system, thus it maximizes the amount of extracted natural gas to be conveyed to another site for an ulterior utilization. Here a robust maximum power point tracker (MPPT using incremental conductance algorithm is applied to the duty cycle value of the DC-DC converter which acts directly on the drive speed. A DC/DC boost is used to enhance voltage up to the favourite level and the SVPWM inverter connects it to a powerful induction motor for a pumping of natural gas application, these systems are at the heart of many industrial sectors such as the oil industry, the production of thermal and nuclear energy etc. An understanding of how these systems operate is essential to increase their performance and reduce their operating costs. Furthermore, three phase voltage-fed PWM inverters are recently showing growing popularity for multi-megawatt industrial drive applications, the main purpose of these topologies is to provide a three-phase voltage source, where the amplitude, phase, and frequency of the voltages should always be controllable. The model of a three-phase voltage source inverter is modelled and discussed based on space vector modulation theory. Simulation results are obtained using MATLAB/Simulink environment for effectiveness of the proposed system.

  11. Effect of pumping head on solar water pumping system

    International Nuclear Information System (INIS)

    Benghanem, M.; Daffallah, K.O.; Alamri, S.N.; Joraid, A.A.

    2014-01-01

    Highlights: • Pumping head affect the performances of PV water pumping systems. • The best system efficiency has been obtained for a deep head. • System efficiency increases with decreasing pumping head during low solar radiation. • System efficiency increases with increasing solar radiation. • Increasing PV array size increases flow rate and system efficiency. - Abstract: The photovoltaic water pumping systems (PVWPS) is considered as one of the most promising areas in photovoltaic applications. The aim of this work is to determine the effect of pumping head on PVWPS using the optimum PV array configuration, adequate to supply a DC Helical pump with an optimum energy amount, under the outdoor conditions of Madinah site. Four different pumping head have been tested (50 m, 60 m, 70 m and 80 m). The tests have been carried for a different heads, under sunny daylight hours, in a real well at a farm in Madinah site. The best system efficiency has been obtained for the head of 80 m which is recommended for SQF submersible pump for a deep head. Also, the flow rate Q depends basically on two factors: the pumping head H and the global solar irradiation Hg. The model developed should be able to predict the flow rate Q for any head chosen with a best accuracy

  12. Types of Breast Pumps

    Science.gov (United States)

    ... Devices Consumer Products Breast Pumps Types of Breast Pumps Share Tweet Linkedin Pin it More sharing options ... used for feeding a baby. Types of Breast Pumps There are three basic types of breast pumps: ...

  13. Development of RBMK-1500 Relap5 model by employing main circulation pump trip events at Ignalina NPP date base

    International Nuclear Information System (INIS)

    Kaliatka, A.; Krivoshein, G.; Uspuras, E.

    2001-01-01

    The Ignalina Nuclear Power Plant is a twin-unit with two RBMK-1500, graphite moderated, boiling water, multichannel reactors. The state of the art code RELAP5 was originally designed for Pressurized Water Reactors. Because of unique RBMK design, the application of this code to RBMK-1500 encountered several problems. The paper deals with the development of proper Ignalina NPP RELAP5 model and investigation of MCPs trip events. A successful best estimate RELAP5 model of the Ignalina NPP has been developed. This model includes the reactor main circulation circuit, reactor control systems and plant safety systems required for transient analysis. There were few events when one MCP was inadvertently tripped at the Ignalina NPP. On May 14, 1996 one MCP at Ignalina Unit 2 was inadvertently tripped. The similar event took place on January 23, 1998. During this event, the MCP check valve failed to close, causing a re-circulation loop to develop by means of a reversed flow through the tripped pump. On July 31, 2000 three MCPs at Ignalina Unit 2 were tripped one after another, due to inadvertent activation of fire protection system. Calculations performed with Ignalina NPP RELAP5 model agree favorably with the plant data. The developed RELAP5 model is proper and may be employed for the plant analysis. (author)

  14. Single-phase cadmium telluride thin films deposited by electroless electrodeposition

    International Nuclear Information System (INIS)

    Khrypunov, G.; Klochko, N.; Lyubov, V.; Li, T.; Volkova, N.

    2010-01-01

    Full text : Today cadmium telluride (CdTe) is a leading base material for the fabrication of thin film solar cells. Equally with the creation of traditional thin film photovoltaic devices on the base of CdTe in recent years several approaches have been investigated to develop solar cells with extremely thin (80-500 nm) CdTe absorber (so-called ηE(eta)-solar cells) that offer the potential to reduce recombination losses in the base layers and thus use low cost materials. Until today the CdTe depositions for the η-solar cells manufacture were performed by vapour phase epitaxy under dynamical vacuum at working temperature 750 degrees Celsium or by electrodeposition in the special electrochemical cell equipped with the potentiostat. Development research of simple and inexpensive method for obtaining of the single-phase stoichiometric cadmium telluride films has required an improvement of the electroless electrodeposition technique, which theretofore was characterized by some disadvantages, namely, the CdTe films were polluted by free tellurium additions and the composition of the films was Cd:Te=55:45. So, for the showing up the synthesis of doped or stoichiometric cadmium telluride films conditions and in order to decide the problem of the deposition of single-phase CdTe layers it was researched the electrochemical processes going during electroless electrolysis in sulfate solutions with different acidities and CdSO 4 concentrations. Some film samples during deposition were illuminated by 500 W halogen lamp. Deposition time was 10-15 min. The phase composition and structure of the deposited films were determined by XRD-method, the average sizes of the crystalline grains in the films were estimated using Debye-Scherer formula. The transmittance spectra of the samples were measured by double beam spectrophotometer in the spectral range of 0.6-1.1 μm. Surface morphology of the films was researched by scanning electron microscopy. By means of analysis of the

  15. Design-Oriented Analysis of Slow-Scale Bifurcations in Single Phase DC-AC Inverters via Autonomous Transformation Approach

    Science.gov (United States)

    Zhang, Hao; Ding, Honghui; Yi, Chuanzhi

    2017-06-01

    This paper deals with the design-oriented analysis of slow-scale bifurcations in single phase DC-AC inverters. Since DC-AC inverter belongs to a class of nonautonomous piecewise systems with periodic equilibrium orbits, the original averaged model has to be translated into an equivalent autonomous one via a virtual rotating coordinate transformation in order to simplify the theoretical analysis. Based on the virtual equivalent model, eigenvalue sensitivity is used to estimate the effect of the important parameters on the system stability. Furthermore, theoretical analysis is performed to identify slow-scale bifurcation behaviors by judging in what way the eigenvalue loci of the Jacobian matrix move under the variation of some important parameters. In particular, the underlying mechanism of the slow-scale unstable phenomenon is uncovered and discussed thoroughly. In addition, some behavior boundaries are given in the parameter space, which are suitable for optimizing the circuit design. Finally, physical experiments are performed to verify the above theoretical results.

  16. Novel temporary left ventricular assist system with hydrodynamically levitated bearing pump for bridge to decision: initial preclinical assessment in a goat model.

    Science.gov (United States)

    Kishimoto, Satoru; Takewa, Yoshiaki; Tsukiya, Tomonori; Mizuno, Toshihide; Date, Kazuma; Sumikura, Hirohito; Fujii, Yutaka; Ohnuma, Kentaro; Togo, Konomi; Katagiri, Nobumasa; Naito, Noritsugu; Kishimoto, Yuichiro; Nakamura, Yoshinobu; Nishimura, Motonobu; Tatsumi, Eisuke

    2018-03-01

    The management of heart failure patients presenting in a moribund state remains challenging, despite significant advances in the field of ventricular assist systems. Bridge to decision involves using temporary devices to stabilize the hemodynamic state of such patients while further assessment is performed and a decision can be made regarding patient management. We developed a new temporary left ventricular assist system employing a disposable centrifugal pump with a hydrodynamically levitated bearing. We used three adult goats (body weight, 58-68 kg) to investigate the 30-day performance and hemocompatibility of the newly developed left ventricular assist system, which included the pump, inflow and outflow cannulas, the extracorporeal circuit, and connectors. Hemodynamic, hematologic, and blood chemistry measurements were investigated as well as end-organ effect on necropsy. All goats survived for 30 days in good general condition. The blood pump was operated at a rotational speed of 3000-4500 rpm and a mean pump flow of 3.2 ± 0.6 L min. Excess hemolysis, observed in one goat, was due to the inadequate increase in pump rotational speed in response to drainage insufficiency caused by continuous contact of the inflow cannula tip with the left ventricular septal wall in the early days after surgery. At necropsy, no thrombus was noted in the pump, and no damage caused by mechanical contact was found on the bearing. The newly developed temporary left ventricular assist system using a disposable centrifugal pump with hydrodynamic bearing demonstrated consistent and satisfactory hemodynamic performance and hemocompatibility in the goat model.

  17. Heat pump planning handbook

    CERN Document Server

    Bonin, Jürgen

    2015-01-01

    The Heat Pump Planning Handbook contains practical information and guidance on the design, planning and selection of heat pump systems, allowing engineers, designers, architects and construction specialists to compare a number of different systems and options. Including detailed descriptions of components and their functions and reflecting the current state of technology this guide contains sample tasks and solutions as well as new model calculations and planning evaluations. Also economic factors and alternative energy sources are covered, which are essential at a time of rising heat costs. T

  18. Modeling of collisional excited x-ray lasers using short pulse laser pumping

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, Akira; Moribayashi, Kengo; Utsumi, Takayuki; Tajima, Toshiki [Japan Atomic Energy Research Inst., Neyagawa, Osaka (Japan). Kansai Research Establishment

    1998-03-01

    A simple atomic kinetics model of electron collisional excited x-ray lasers has been developed. The model consists of a collisional radiative model using the average ion model (AIM) and a detailed term accounting (DTA) model of Ni-like Ta. An estimate of plasma condition to produce gain in Ni-like Ta ({lambda}=44A) is given. Use of the plasma confined in a cylinder is proposed to preform a uniform high density plasma from 1-D hydrodynamics calculations. (author)

  19. Analysis on the heating performance of a gas engine driven air to water heat pump based on a steady-state model

    International Nuclear Information System (INIS)

    Zhang, R.R.; Lu, X.S.; Li, S.Z.; Lin, W.S.; Gu, A.Z.

    2005-01-01

    In this study, the heating performance of a gas engine driven air to water heat pump was analyzed using a steady state model. The thermodynamic model of a natural gas engine is identified by the experimental data and the compressor model is created by several empirical equations. The heat exchanger models are developed by the theory of heat balance. The system model is validated by comparing the experimental and simulation data, which shows good agreement. To understand the heating characteristic in detail, the performance of the system is analyzed in a wide range of operating conditions, and especially the effect of engine waste heat on the heating performance is discussed. The results show that engine waste heat can provide about 1/3 of the total heating capacity in this gas engine driven air to water heat pump. The performance of the engine, heat pump and integral system are analyzed under variations of engine speed and ambient temperature. It shows that engine speed has remarkable effects on both the engine and heat pump, but ambient temperature has little influence on the engine's performance. The system and component performances in variable speed operating conditions is also discussed at the end of the paper

  20. Energetics analysis of interstitial loops in single-phase concentrated solid-solution alloys

    Science.gov (United States)

    Wang, Xin-Xin; Niu, Liang-Liang; Wang, Shaoqing

    2018-04-01

    Systematic energetics analysis on the shape preference, relative stability and radiation-induced segregation of interstitial loops in nickel-containing single-phase concentrated solid-solution alloys have been conducted using atomistic simulations. It is shown that the perfect loops prefer rhombus shape for its low potential energy, while the Frank faulted loops favor ellipse for its low potential energy and the possible large configurational entropy. The decrease of stacking fault energy with increasing compositional complexity provides the energetic driving force for the formation of faulted loops, which, in conjunction with the kinetic factors, explains the experimental observation that the fraction of faulted loops rises with increasing compositional complexity. Notably, the kinetics is primarily responsible for the absence of faulted loops in nickel-cobalt with a very low stacking fault energy. We further demonstrate that the simultaneous nickel enrichment and iron/chromium depletion on interstitial loops can be fully accounted for by their energetics.

  1. Single-Phase Microgrid with Seamless Transition Capabilities between Modes of Operation

    DEFF Research Database (Denmark)

    Micallef, Alexander; Apap, Maurice; Spiteri-Staines, Cyril

    2015-01-01

    Microgrids are an effective way to increase the penetration of DG into the grid. They are capable of operating either in grid-connected or in islanded mode thereby increasing the supply reliability for the end user. This paper focuses on achieving seamless transitions from islanded to grid......-connected and vice versa for a single phase microgrid made up from voltage controlled voltage source inverters (VC-VSIs) and current controlled voltage source inverters (CC-VSIs) working together in both modes of operation. The primary control structures for the VC-VSIs and CC-VSIs is considered together...... with the secondary control loops that are used to synchronize the microgrid as a single unit to the grid. Simulation results are given that show the seamless transitions between the two modes without any disconnection times for the CC-VSIs and VC-VSIs connected to the microgrid....

  2. Low voltage ride-through of single-phase transformerless photovoltaic inverters

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede; Wang, Huai

    2013-01-01

    Transformerless photovoltaic (PV) inverters are going to be more widely adopted in order to achieve high efficiency, as the penetration level of PV systems is continuously booming. However, problems may arise in highly PV-integrated distribution systems. For example, a sudden stoppage of all PV...... systems due to anti-islanding protection may trigger grid disturbances. Thus, standards featuring with ancillary services for the next generation PV systems are under a revision in some countries. The future PV systems have to provide a full range of services as what the conventional power plants do, e...... discussed. The selected inverters are the full-bridge inverter with bipolar modulation, full-bridge inverter with DC bypass and the Highly Efficient and Reliable Inverter Concept (HERIC). A 1 kW single-phase grid-connected PV system is analyzed to verify the discussions. The tests confirmed that, although...

  3. Reactive Power Injection Strategies for Single-Phase Photovoltaic Systems Considering Grid Requirements

    DEFF Research Database (Denmark)

    Yang, Yongheng; Wang, Huai; Blaabjerg, Frede

    2014-01-01

    .g. Germany and Italy. Those advanced features can be provided by next generation PV systems, and will be enhanced in the future to ensure an even efficient and reliable utilization of PV systems. In light of this, Reactive Power Injection (RPI) strategies for single-phase PV systems are explored...... like what the conventional power plants do today in the grid regulation participation. Requirements of ancillary services like Low-Voltage Ride-Through (LVRT) associated with reactive current injection and voltage support through reactive power control, have been in effectiveness in some countries, e...... in this paper. The RPI possibilities are: a) constant average active power control, b) constant active current control, c) constant peak current control and d) thermal optimized control strategy. All those strategies comply with the currently active grid codes, but are with different objectives. The proposed...

  4. Reactive Power Injection Strategies for Single-Phase Photovoltaic Systems Considering Grid Requirements

    DEFF Research Database (Denmark)

    Yang, Yongheng; Wang, Huai; Blaabjerg, Frede

    2014-01-01

    . Those advanced features can be provided by next-generation PV systems, and will be enhanced in the future to ensure an even efficient and reliable utilization of PV systems. In the light of this, Reactive Power Injection (RPI) strategies for single-phase PV systems are explored in this paper. The RPI...... like what the conventional power plants do today in the grid regulation participation. Requirements of ancillary services like Low-Voltage Ride-Through (LVRT) associated with reactive current injection and voltage support through reactive power control, have been in effectiveness in some countries...... possibilities are: a) constant average active power control, b) constant active current control, c) constant peak current control and d) thermal optimized control strategy. All those strategies comply with the currently active grid codes, but are with different objectives. The thermal optimized control strategy...

  5. Abrasion resistance, microhardness and microstructures of single-phase niobium nitride films

    International Nuclear Information System (INIS)

    Singer, I.L.; Bolster, R.N.; Wolf, S.A.; Skelton, E.F.; Jeffries, R.A.

    1983-01-01

    The relative abrasive wear resistance of single-phase niobium nitride films deposited at 900 and 500 0 C was measured. Wear resistance versus depth profiles of films abraded against 1-5 μm diamond were obtained by weight loss methods. A β phase Nb 2 N film was five to 20 times more abrasion resistant, but only slightly (40%) harder, than the delta phase NbN films made at the same temperature. The β-Nb 2 N film was deformed plastically during wear, reorienting the [002] c axis perpendicular to the plane of the substrate. The abrasion resistance of the delta-NbN films was initially proportional to the microhardness. Two films had changes in their abrasion resistance as wear proceeded: for one film the change was attributable to deviations in stoichiometry and for the other film it was attributable to increased lattice distortion. (Auth.)

  6. Influence of modulation method on using LC-traps with single-phase voltage source converters

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Min, Huang; Bai, Haofeng

    2015-01-01

    The switching-frequency LC-trap filter has recently been employed with high-order passive filters for Voltage Source Inverters (VSIs). This paper investigates the influence of modulation method on using the LC-traps with single-phase VSIs. Two-level (bipolar) and three-level (unipolar) modulations...... that include phase distortion and alternative phase opposition distortion methods are analyzed. Harmonic filtering performances of four LC-trap-based filters with different locations of LC-traps are compared. It is shown that the use of parallel-LC-traps in series with filter inductors, either grid...... or converter side, has a worse harmonic filtering performance than using series-LC-trap in the shunt branch. Simulations and experimental results are presented for verifications....

  7. Broadband single-phase hyperbolic elastic metamaterials for super-resolution imaging.

    Science.gov (United States)

    Dong, Hao-Wen; Zhao, Sheng-Dong; Wang, Yue-Sheng; Zhang, Chuanzeng

    2018-02-02

    Hyperbolic metamaterials, the highly anisotropic subwavelength media, immensely widen the engineering feasibilities for wave manipulation. However, limited by the empirical structural topologies, the reported hyperbolic elastic metamaterials (HEMMs) suffer from the limitations of the relatively narrow frequency width, inflexible adjustable operating subwavelength scale and difficulty to further improve the imaging resolution. Here, we show an inverse-design strategy for HEMMs by topology optimization. We design broadband single-phase HEMMs supporting multipolar resonances at different prescribed deep-subwavelength scales, and demonstrate the super-resolution imaging for longitudinal waves. Benefiting from the extreme enhancement of the evanescent waves, an optimized HEMM at an ultra-low frequency can yield an imaging resolution of ~λ/64, representing the record in the field of elastic metamaterials. The present research provides a novel and general design methodology for exploring the HEMMs with unrevealed mechanisms and guides the ultrasonography and general biomedical applications.

  8. Pressure drop characteristics of single-phase flow in vertical rolling pipes

    International Nuclear Information System (INIS)

    Cao Xiaxin; Yan Changqi; Sun Licheng; Sun Zhongning

    2007-01-01

    Experimental studies of single-phase pressure drop in rolling pipes were carried out. The inside diameters of three pipes which were fixed on the rolling platform were 15 mm, 25 mm, and 34.5 mm respectively, the rolling periods of the rolling platform could be set as 5s, 10s, 15s, and rolling angles of the rolling platform were 10 degree and 20 degree. The experimental results showed that the frictional factor periodically fluctuated with the time variable, and its amplitude was obviously affected by the change of Reynolds number and pipe diameters. The amplitude and average value of frictional factor both decreased with the increase of Re number, but the bigger the tube diameter was, the larger the amplitude of frictional factor was. At any moment, the transient frictional factor increased with the increase of rolling period. However, the effect of changing rolling angles on the frictional factor was not obvious. (authors)

  9. Green synthesis of isopropyl myristate in novel single phase medium Part I: Batch optimization studies.

    Science.gov (United States)

    Vadgama, Rajeshkumar N; Odaneth, Annamma A; Lali, Arvind M

    2015-12-01

    Isopropyl myristate finds many applications in food, cosmetic and pharmaceutical industries as an emollient, thickening agent, or lubricant. Using a homogeneous reaction phase, non-specific lipase derived from Candida antartica, marketed as Novozym 435, was determined to be most suitable for the enzymatic synthesis of isopropyl myristate. The high molar ratio of alcohol to acid creates novel single phase medium which overcomes mass transfer effects and facilitates downstream processing. The effect of various reaction parameters was optimized to obtain a high yield of isopropyl myristate. Effect of temperature, agitation speed, organic solvent, biocatalyst loading and batch operational stability of the enzyme was systematically studied. The conversion of 87.65% was obtained when the molar ratio of isopropyl alcohol to myristic acid (15:1) was used with 4% (w/w) catalyst loading and agitation speed of 150 rpm at 60 °C. The enzyme has also shown good batch operational stability under optimized conditions.

  10. Rotor Design for an Efficient Single-Phase Induction Motor for Refrigerator Compressors

    Directory of Open Access Journals (Sweden)

    Hyun-Jin Ahn

    2016-03-01

    Full Text Available This article describes a rotor making technology for the production of high-efficiency single-phase induction motors (SPIMs to be used in refrigerator compressors. Rotors can have different aluminum fill factors according to the fabrication method. In order to examine the association between the fill factor and the efficiency of the rotor, we analyzed the distribution of magnetic flux density using the finite element method (FEM. Next, we made prototype rotors by conventional casting methods and by the proposed casting method and compared their fill factors. In addition, SPIMs were made using the rotors, and their efficiencies were measured using a dynamometer. Moreover, the SPIMs were put to use in a compressor, for testing, and for each SPIM the refrigerating capacity of the compressor was measured with a calorimeter. Based on the results of the FEM analysis of the magnetic flux density and the experiments, the reliability and validity of the proposed method were proven.

  11. Control of single-phase islanded PV/battery minigrids based on power-line signaling

    DEFF Research Database (Denmark)

    Quintana, Pablo; Guerrero, Josep M.; Dragicevic, Tomislav

    2014-01-01

    Power regulation of all converter units in a micro-grid should not be only determined by load demand, but also by the available power of each unit, i.e. a converter fed by a battery. Energy management control is essential in order to handle the variety of prime movers which may include different...... should be utilized as efficiently as possible. This paper proposes a coordinated control strategy based on power-line signaling (PLS), instead of common communications, for a single-phase minigrid in which each unit can operate in different operation modes taking into account the resource limitation....... The whole system is explained ahead and finally, Hardware in the loop results obtained with a dSPACE are presented in order to validate the proposed control strategy....

  12. Decoupling of fluctuating power in single-phase systems through a symmetrical half-bridge circuit

    DEFF Research Database (Denmark)

    Tang, Yi; Blaabjerg, Frede; Loh, Poh Chiang

    2014-01-01

    Single-phase AC/DC or DC/AC systems inherently subject to harmonic disturbance which is caused by the well-known double line frequency ripple power. This issue can be eased through the installation of bulky electrolytic capacitors in the dc-link, but such passive filtering approach may inevitably...... or film capacitors to store the ripple power, and this again leads to increased component costs. In view of this, this paper presents a symmetrical half-bridge circuit which utilizes the dc-link capacitors to absorb the ripple power, and the only additional components are a pair of switches and a small...... filtering inductor. A design example is presented and the proposed circuit concept is also verified with simulation and experimental results. It shows that at least ten times capacitance reduction can be achieved with the proposed active power decoupling method, which proves its effectiveness....

  13. Realization of single-phase single-stage grid-connected PV system

    Directory of Open Access Journals (Sweden)

    Osama M. Arafa

    2017-05-01

    Full Text Available This paper presents a single phase single stage grid-tied PV system. Grid angle detection is introduced to allow operation at any arbitrary power factor but unity power factor is chosen to utilize the full inverter capacity. The system ensures MPPT using the incremental conductance method and it can track the changes in insolation level without oscillations. A PI voltage controller and a dead-beat current controller are used to ensure high quality injected current to the grid. The paper investigates the system structure and performance through numerical simulation using Matlab/Simulink. An experimental setup controlled by the MicrolabBox DSP prototyping platform is utilized to realize the system and study its performance. The precautions for smooth and safe system operation including the startup sequence are fully considered in the implementation.

  14. Adaptive fuzzy sliding control of single-phase PV grid-connected inverter.

    Directory of Open Access Journals (Sweden)

    Juntao Fei

    Full Text Available In this paper, an adaptive fuzzy sliding mode controller is proposed to control a two-stage single-phase photovoltaic (PV grid-connected inverter. Two key technologies are discussed in the presented PV system. An incremental conductance method with adaptive step is adopted to track the maximum power point (MPP by controlling the duty cycle of the controllable power switch of the boost DC-DC converter. An adaptive fuzzy sliding mode controller with an integral sliding surface is developed for the grid-connected inverter where a fuzzy system is used to approach the upper bound of the system nonlinearities. The proposed strategy has strong robustness for the sliding mode control can be designed independently and disturbances can be adaptively compensated. Simulation results of a PV grid-connected system verify the effectiveness of the proposed method, demonstrating the satisfactory robustness and performance.

  15. Rapid synthesis of single-phase bismuth ferrite by microwave-assisted hydrothermal method

    International Nuclear Information System (INIS)

    Cao, Wenqian; Chen, Zhi; Gao, Tong; Zhou, Dantong; Leng, Xiaonan; Niu, Feng; Zhu, Yuxiang; Qin, Laishun; Wang, Jiangying; Huang, Yuexiang

    2016-01-01

    This paper describes on the fast synthesis of bismuth ferrite by the simple microwave-assisted hydrothermal method. The phase transformation and the preferred growth facets during the synthetic process have been investigated by X-ray diffraction. Bismuth ferrite can be quickly prepared by microwave hydrothermal method by simply controlling the reaction time, which is further confirmed by Fourier Transform infrared spectroscopy and magnetic measurement. - Graphical abstract: Single-phase BiFeO 3 could be realized at a shortest reaction time of 65 min. The reaction time has strong influences on the phase transformation and the preferred growth facets. - Highlights: • Rapid synthesis (65 min) of BiFeO 3 by microwave-assisted hydrothermal method. • Reaction time has influence on the purity and preferred growth facets. • FTIR and magnetic measurement further confirm the pure phase.

  16. S4 Grid-Connected Single-Phase Transformerless Inverter for PV Application

    DEFF Research Database (Denmark)

    Ardashir, Jaber Fallah; Siwakoti, Yam Prasad; Sabahi, Mehran

    2016-01-01

    This paper introduces a new single-phase transformerless inverter for grid-connected photovoltaic systems with low leakage current. It consists of four power switches, two diodes, two capacitors and a filter at the output stage. The neutral of the grid is directly connected to the negative terminal...... of the PV source. This results in a constant common-mode voltage and almost zero leakage current. A unipolar Sinusoidal Pulse-Width Modulation (SPWM) technique is used to modulate the inverter to reduce the output current ripple and the filter requirements. The main advantages of this inverter are compact...... clearly verify the performance of the proposed inverter and its practical application for grid-connected PV systems....

  17. Compact ASD Topologies for Single-Phase Integrated Motor Drives with Sinusoidal Input Current

    DEFF Research Database (Denmark)

    Klumpner, Christian; Blaabjerg, Frede; Thoegersen, Paul

    2005-01-01

    A standard configuration of an Adjustable Speed Drive (ASD) consists of two separate units: an AC motor, which runs with fixed speed when it is supplied from a constant frequency grid voltage and a frequency converter, which is used to provide the motor with variable voltage-variable frequency......-density integration of the converter caused by the large size of the passive components (electrolytic capacitors and iron chokes) and vibration of the converter enclosure. This paper analyzes the implementation aspects for obtaining a compact and cost effective single-phase ASD with sinusoidal input current...... for high frequency operation, higher core losses will occur, but outside the converter enclosure. The advantages are: the reduction of the number of active semiconductor devices, the reduction of the ASD size and the better integration potential....

  18. A Rotor Flux and Speed Observer for Sensorless Single-Phase Induction Motor Applications

    Directory of Open Access Journals (Sweden)

    Massimo Caruso

    2012-01-01

    Full Text Available It is usual to find single-phase induction motor (SPIM in several house, office, shopping, farm, and industry applications, which are become each time more sophisticated and requiring the development of efficient alternatives to improve the operational performance of this machine. Although the rotor flux and rotational speed are essential variables in order to optimize the operation of a SPIM, the use of conventional sensors to measure them is not a viable option. Thus, the adoption of sensorless strategies is the more reasonable proposal for these cases. This paper presents a rotor flux and rotational speed observer for sensorless applications involving SPIMs. Computer simulations and the experimental results are used to verify the performance of the proposed observer.

  19. Factors that affect the calibration of turbines in single-phase flow

    Energy Technology Data Exchange (ETDEWEB)

    Piper, T. C.

    1977-05-01

    Basic turbine operation in single-phase flow is related. Causes and relative magnitudes of retarding torque are given for two sizes of turbines when used for water flow measurement. An equation for slip caused by retarding torques is given. Evaluation of turbine slip behavior at the turbine low flow region shows that bearing retarding torques, change in flow patterns, or other effects can predominate in the relatively large changes in the calibration ''constant'' that occurs there. Fluid lubricity is singled out as an important fluid property in certain types of bearings and flow. Temperature induced changes in turbine size are shown to cause calibration changes if a turbine is used at a temperature significantly different than that at which it was calibrated.

  20. Factors that affect the calibration of turbines in single-phase flow

    International Nuclear Information System (INIS)

    Piper, T.C.

    1977-05-01

    Basic turbine operation in single-phase flow is related. Causes and relative magnitudes of retarding torque are given for two sizes of turbines when used for water flow measurement. An equation for slip caused by retarding torques is given. Evaluation of turbine slip behavior at the turbine low flow region shows that bearing retarding torques, change in flow patterns, or other effects can predominate in the relatively large changes in the calibration ''constant'' that occurs there. Fluid lubricity is singled out as an important fluid property in certain types of bearings and flow. Temperature induced changes in turbine size are shown to cause calibration changes if a turbine is used at a temperature significantly different than that at which it was calibrated

  1. Single-phase pressure-drop measurements over low void reactivity fuel

    International Nuclear Information System (INIS)

    Senaratne, U.P.M.; Leung, L.K.H.; Doria, F.J.; Lau, J.H.

    2006-01-01

    An experiment has been performed to obtain pressure-drop measurements over Low Reactivity Fuel (LVRF) bundles in Refrigerant-134a flow. Production LVRF bundles inserted into the test station with either an uncrept or a 5.1% crept flow channel. For comparison purposes, several production Bruce 37-element bundles were also included in the test string. Overall, the single-phase pressure drop of the LVRF bundle is slightly higher than that Bruce 37-element bundle. Pressure-drop measurements were used to derive bundle and loss coefficients for hydraulic calculations in safety analyses. Applying these loss coefficients, an assessment showed that the overall pressure drop over a string of 12 LVRF bundles (after conversion) remains less than that over a string of 13 Bruce 37-element fuel bundles (before conversion) at the Bruce Nuclear Generating Station. (author)

  2. Calculation of single phase AC and monopolar DC hybrid corona effects

    International Nuclear Information System (INIS)

    Zhao, T.; Sebo, S.A.; Kasten, D.G.

    1996-01-01

    Operating a hybrid HVac and HVdc line is an option for increasing the efficiency of power transmission and overcoming the difficulties in obtaining a new right-of-way. This paper proposes a new calculation method for the study of hybrid line corona. The proposed method can be used to calculate dc corona losses and corona currents in dc or ac conductors for single phase ac and monopolar dc hybrid lines. Profiles of electric field strength and ion current density at ground level can be estimated. The effects of the presence of an energized ac conductor on dc conductor corona and dc voltage on ac conductor corona are included in the method. Full-scale and reduced-scale experiments were utilized to investigate the hybrid line corona effects. Verification of the proposed calculation method is given

  3. Hybrid Three-Phase/Single-Phase Microgrid Architecture with Power Management Capabilities

    DEFF Research Database (Denmark)

    Sun, Qiuye; Zhou, Jianguo; Guerrero, Josep M.

    2015-01-01

    With the fast proliferation of single-phase distributed generation (DG) units and loads integrated into residential microgrids, independent power sharing per phase and full use of the energy generated by DGs have become crucial. To address these issues, this paper proposes a hybrid microgrid...... control of load power sharing among phases, as well as to allow fully utilization of the energy generated by DGs. Meanwhile, the method combining the modified adaptive backstepping-sliding mode control approach and droop control is also proposed to design the SPBTB system controllers. With the application...... of the proposed PSU and its power management strategy, the loads among different phases can be properly supplied and the energy can be fully utilized as well as obtaining better load sharing. Simulation and experimental results are provided to demonstrate the validity of the proposed hybrid microgrid structure...

  4. Comparative study of Nusselt number for a single phase fluid flow using plate heat exchanger

    Directory of Open Access Journals (Sweden)

    Shanmugam Rajasekaran

    2016-01-01

    Full Text Available In this study, the plate heat exchangers are used for various applications in the industries for heat exchange process such as heating, cooling and condensation. The performance of plate heat exchanger depends on many factors such as flow arrangements, plate design, chevron angle, enlargement factor, type of fluid used, etc. The various Nusselt number correlations are developed by considering that the water as a working fluid. The main objective of the present work is to design the experimental set-up for a single phase fluid flow using plate heat exchanger and studied the heat transfer performance. The experiments are carried out for various Reynolds number between 500 and 2200, the heat transfer coefficients are estimated. Based on the experimental results the new correlation is developed for Nusselt number and compared with an existing correlation.

  5. Scaling analysis for the ocean motions in single phase natural circulation

    International Nuclear Information System (INIS)

    Yan, B.H.; Wen, Q.L.

    2015-01-01

    Highlights: • The scaling criteria for ocean motions are obtained. • The optimization and selection of the scaling criteria is also analyzed. • The oscillating period in experiments is determined by the time scale. - Abstract: The effects of ocean motions should be analyzed properly in order to guarantee the safety margin of facilities in the engineering design of floating nuclear reactor system. The scaling analysis for the ocean motions in single phase natural circulation is performed. The scaling criteria for both single ocean motions and compound ocean motions are obtained. The selection and optimization of scaling criteria is also analyzed. The oscillating amplitude in experiments should be kept to be identical to that in actual ocean motions. The oscillating period is determined by the time scale. The length scale, oscillating period and experimental power should be taken into consideration synthetically to obtain a reasonable experimental period

  6. Time domain spectral phase encoding/DPSK data modulation using single phase modulator for OCDMA application.

    Science.gov (United States)

    Wang, Xu; Gao, Zhensen; Kataoka, Nobuyuki; Wada, Naoya

    2010-05-10

    A novel scheme using single phase modulator for simultaneous time domain spectral phase encoding (SPE) signal generation and DPSK data modulation is proposed and experimentally demonstrated. Array- Waveguide-Grating and Variable-Bandwidth-Spectrum-Shaper based devices can be used for decoding the signal directly in spectral domain. The effects of fiber dispersion, light pulse width and timing error on the coding performance have been investigated by simulation and verified in experiment. In the experiment, SPE signal with 8-chip, 20GHz/chip optical code patterns has been generated and modulated with 2.5 Gbps DPSK data using single modulator. Transmission of the 2.5 Gbps data over 34km fiber with BEROCDMA) and secure optical communication applications. (c) 2010 Optical Society of America.

  7. Adaptive fuzzy sliding control of single-phase PV grid-connected inverter.

    Science.gov (United States)

    Fei, Juntao; Zhu, Yunkai

    2017-01-01

    In this paper, an adaptive fuzzy sliding mode controller is proposed to control a two-stage single-phase photovoltaic (PV) grid-connected inverter. Two key technologies are discussed in the presented PV system. An incremental conductance method with adaptive step is adopted to track the maximum power point (MPP) by controlling the duty cycle of the controllable power switch of the boost DC-DC converter. An adaptive fuzzy sliding mode controller with an integral sliding surface is developed for the grid-connected inverter where a fuzzy system is used to approach the upper bound of the system nonlinearities. The proposed strategy has strong robustness for the sliding mode control can be designed independently and disturbances can be adaptively compensated. Simulation results of a PV grid-connected system verify the effectiveness of the proposed method, demonstrating the satisfactory robustness and performance.

  8. Effects of rolling on single-phase water forced convective heat transfer characteristics

    International Nuclear Information System (INIS)

    Guo Yanming; Gao Puzhen; Huang Zhen

    2010-01-01

    A series of single-phase forced circulation tests in a vertical tube with rolling motion were performed in order to investigate effects of rolling motion on thermal-hydraulic characteristics. The amplitudes of the rolling motion in the tests were 10 degree, 15 degree and 20 degree. The rolling periods were 7.5 s, 10 s, 15 s and 20 s. The Reynolds number was from 6000 to 15000. Heat transfer in the test tube is bated by the rolling motion. As the test-bed rolling more acutely, the heat transfer coefficient of the test tube becomes smaller when the mass flow rate in the test tube is a constant. The heat transfer coefficient calculated by the formula which is for stable state doesn't fit very well with that from experiments. At last a formula for calculating heat transfer in rolling motion was introduced. (authors)

  9. A Robust DC-Split-Capacitor Power Decoupling Scheme for Single-Phase Converter

    DEFF Research Database (Denmark)

    Yao, Wenli; Loh, Poh Chiang; Tang, Yi

    2017-01-01

    , instead of the usual single dc-link capacitor bank. Methods for regulating this power decoupler have earlier been developed, but almost always with equal capacitances assumed for forming the dc-split capacitor, even though it is not realistic in practice. The assumption should, hence, be evaluated more......Instead of bulky electrolytic capacitors, active power decoupling circuit can be introduced to a single-phase converter for diverting second harmonic ripple away from its dc source or load. One possible circuit consists of a half-bridge and two capacitors in series for forming a dc-split capacitor...... thoroughly, especially when it is shown in the paper that even a slight mismatch can render the power decoupling scheme ineffective and the IEEE 1547 standard to be breached. A more robust compensation scheme is, thus, needed for the dc-split capacitor circuit, as proposed and tested experimentally...

  10. Zero-voltage ride-through capability of single-phase grid-connected photovoltaic systems

    DEFF Research Database (Denmark)

    Zhang, Zhen; Yang, Yongheng; Ma, Ruiqing

    2017-01-01

    Distributed renewable energy systems play an increasing role in today’s energy paradigm. Thus, intensive research activities have been centered on improving the performance of renewable energy systems, including photovoltaic (PV) systems, which should be of multiple-functionality. That is, the PV...... systems should be more intelligent in the consideration of grid stability, reliability, and fault protection. Therefore, in this paper, the performance of single-phase grid-connected PV systems under an extreme grid fault (i.e., when the grid voltage dips to zero) is explored. It has been revealed...... that combining a fast and accurate synchronization mechanism with appropriate control strategies for the zero-voltage ride-through (ZVRT) operation is mandatory. Accordingly, the representative synchronization techniques (i.e., the phase-locked loop (PLL) methods) in the ZVRT operation are compared in terms...

  11. Optical Dynamic Analysis of Thrombus Inside a Centrifugal Blood Pump During Extracorporeal Mechanical Circulatory Support in a Porcine Model.

    Science.gov (United States)

    Fujiwara, Tatsuki; Sakota, Daisuke; Ohuchi, Katsuhiro; Endo, Shu; Tahara, Tomoki; Murashige, Tomotaka; Kosaka, Ryo; Oi, Keiji; Mizuno, Tomohiro; Maruyama, Osamu; Arai, Hirokuni

    2017-10-01

    Complications due to pump thrombus remain the weak point of mechanical circulatory support (MCS), such as the use of a left ventricular assist device (LVAD) or extracorporeal membrane oxygenation, leading to poor outcomes. Hyperspectral imaging (HSI) is an effective imaging method using a hyperspectral (HS) camera, which comprises a spectrophotometer and a charge-coupled device camera to discriminate thrombus from whole blood. Animal experiments were conducted to analyze dynamic imaging of thrombus inside a prototype of a hydrodynamically levitated centrifugal blood pump using an HSI system. Six pigs were divided into a venous circulation group (n = 3) and an arterial circulation group (n = 3). Inflow and outflow cannulae were inserted into the jugular veins in the venous circulation group. The latter simulated an LVAD application. To create thrombogenic conditions, pump flow was maintained at 1 L/min without anticoagulation. An image of the bottom surface of the pump was captured by the HS camera every 4 nm over the wavelength range of 608-752 nm. Real-time dynamic images of the inside of the pump were displayed on the monitor. Appearance of an area displaying thrombus was detected within 24 h after the start of the circulation in every experiment. This imaging system also succeeded in determining the origins of pump thrombus: from inside the pump in two cases, and from outside in four cases. Two main possible sources of pump thrombus originating outside the pump were identified on autopsy: wedge thrombus around the inflow cannula; and string-like thrombus at the junction between the pump inlet and circuit tube. The results of this study from close observation of the changing appearance of pump thrombus may contribute to improvements in the safety of extracorporeal MCS. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  12. Development of suitability maps for ground-coupled heat pump systems using groundwater and heat transport models

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Hikari; Itoi, Ryuichi [Department of Earth Resources Engineering, Faculty of Engineering, Kyushu University, Motooka 744, Nishi-ku, Fukuoka 819-0395 (Japan); Inatomi, Tadasuke [YBM Co. Ltd., Kishiyama 589-10 Kitahata, Karatsu 847-1211 (Japan); Uchida, Youhei [Geological Survey of Japan, AIST Tsukuba Central 7, Tsukuba 305-8567 (Japan)

    2007-10-15

    The thermophysical properties of subsurface materials (soils, sediments and rocks) and groundwater flow strongly affect the heat exchange rates of ground heat exchangers (GHEs). These rates can be maximized and the installation costs of the ground-coupled heat pump (GCHP) systems reduced by developing suitability maps based on local geological and hydrological information. Such maps were generated for the Chikushi Plain (western Japan) using field-survey data and a numerical modeling study. First, a field-wide groundwater model was developed for the area and the results matched against measured groundwater levels and vertical temperature profiles. Single GHE models were then constructed to simulate the heat exchange performance at different locations in the plain. Finally, suitability maps for GCHP systems were prepared using the results from the single GHE models. Variations in the heat exchange rates of over 40% revealed by the map were ascribed to differences in the GHE locations, confirming how important it is to use appropriate thermophysical data when designing GCHP systems. (author)

  13. A study of Ground Source Heat Pump based on a heat infiltrates coupling model established with FEFLOW

    Science.gov (United States)

    Chen, H.; Hu, C.; Chen, G.; Zhang, Q.

    2017-12-01

    Geothermal heat is a viable source of energy and its environmental impact in terms of CO2 emissions is significantly lower than conventional fossil fuels. it is vital that engineers acquire a proper understanding about the Ground Source Heat Pump (GSHP). In this study, the model of the borehole exchanger under conduction manners and heat infiltrates coupling manners was established with FEFLOW. The energy efficiency, heat transfer endurance and heat transfer in the unit depth were introduced to quantify the energy efficient and the endurance period. The performance of a the Borehole Exchanger (BHE) in soil with and without groundwater seepage was analyzed of heat transfer process between the soil and the working fluid. Basing on the model, the varied regularity of energy efficiency performance an heat transfer endurance with the conditions including the different configuration of the BHE, the soil properties, thermal load characteristic were discussed. Focus on the heat transfer process in multi-layer soil which one layer exist groundwater flow. And an investigation about thermal dispersivity was also analyzed its influence on heat transfer performance. The final result proves that the model of heat infiltrates coupling model established in this context is reasonable, which can be applied to engineering design.

  14. Single-phase dual-energy CT urography in the evaluation of haematuria.

    Science.gov (United States)

    Ascenti, G; Mileto, A; Gaeta, M; Blandino, A; Mazziotti, S; Scribano, E

    2013-02-01

    To assess the value of a single-phase dual-energy computed tomography (DECT) urography protocol with synchronous nephrographic-excretory phase enhancement and to calculate the potential dose reduction by omitting the unenhanced scan. Eighty-four patients referred for haematuria underwent CT urography using a protocol that included single-energy unenhanced and dual-energy contrast-enhanced with synchronous nephrographic-excretory phase scans. DECT-based images [virtual unenhanced (VUE), weighted average, and colour-coded iodine overlay] were reconstructed. Opacification degree by contrast media of the upper urinary tract, and image quality of virtual unenhanced images were independently evaluated using a four-point scale. The diagnostic accuracy in detecting urothelial tumours on DECT-based images was determined. The dose of a theoretical dual-phase single-energy protocol was obtained by multiplying the effective dose of the unenhanced single-energy acquisition by two. Radiation dose saving by omitting the unenhanced scan was calculated. The degree of opacification was scored as optimal or good in 86.9% of cases (k = 0.72); VUE image quality was excellent or good in 83.3% of cases (k = 0.82). Sensitivity, specificity, positive predictive value, and negative predictive value for urothelial tumours detection were 85.7, 98.6, 92.3, and 97.1%. Omission of the unenhanced scan led to a mean dose reduction of 42.7 ± 5%. Single-phase DECT urography with synchronous nephrographic-excretory phase enhancement represents an accurate "all-in-one'' approach with a radiation dose saving up to 45% compared with a standard dual-phase protocol. Copyright © 2012 The Royal College of Radiologists. All rights reserved.

  15. Single-phase dual-energy CT urography in the evaluation of haematuria

    International Nuclear Information System (INIS)

    Ascenti, G.; Mileto, A.; Gaeta, M.; Blandino, A.; Mazziotti, S.; Scribano, E.

    2013-01-01

    Aim: To assess the value of a single-phase dual-energy computed tomography (DECT) urography protocol with synchronous nephrographic–excretory phase enhancement and to calculate the potential dose reduction by omitting the unenhanced scan. Materials and methods: Eighty-four patients referred for haematuria underwent CT urography using a protocol that included single-energy unenhanced and dual-energy contrast-enhanced with synchronous nephrographic–excretory phase scans. DECT-based images [virtual unenhanced (VUE), weighted average, and colour-coded iodine overlay] were reconstructed. Opacification degree by contrast media of the upper urinary tract, and image quality of virtual unenhanced images were independently evaluated using a four-point scale. The diagnostic accuracy in detecting urothelial tumours on DECT-based images was determined. The dose of a theoretical dual-phase single-energy protocol was obtained by multiplying the effective dose of the unenhanced single-energy acquisition by two. Radiation dose saving by omitting the unenhanced scan was calculated. Results: The degree of opacification was scored as optimal or good in 86.9% of cases (k = 0.72); VUE image quality was excellent or good in 83.3% of cases (k = 0.82). Sensitivity, specificity, positive predictive value, and negative predictive value for urothelial tumours detection were 85.7, 98.6, 92.3, and 97.1%. Omission of the unenhanced scan led to a mean dose reduction of 42.7 ± 5%. Conclusion: Single-phase DECT urography with synchronous nephrographic–excretory phase enhancement represents an accurate “all-in-one’’ approach with a radiation dose saving up to 45% compared with a standard dual-phase protocol.

  16. Accurate prediction of complex free surface flow around a high speed craft using a single-phase level set method

    Science.gov (United States)

    Broglia, Riccardo; Durante, Danilo

    2017-11-01

    This paper focuses on the analysis of a challenging free surface flow problem involving a surface vessel moving at high speeds, or planing. The investigation is performed using a general purpose high Reynolds free surface solver developed at CNR-INSEAN. The methodology is based on a second order finite volume discretization of the unsteady Reynolds-averaged Navier-Stokes equations (Di Mascio et al. in A second order Godunov—type scheme for naval hydrodynamics, Kluwer Academic/Plenum Publishers, Dordrecht, pp 253-261, 2001; Proceedings of 16th international offshore and polar engineering conference, San Francisco, CA, USA, 2006; J Mar Sci Technol 14:19-29, 2009); air/water interface dynamics is accurately modeled by a non standard level set approach (Di Mascio et al. in Comput Fluids 36(5):868-886, 2007a), known as the single-phase level set method. In this algorithm the governing equations are solved only in the water phase, whereas the numerical domain in the air phase is used for a suitable extension of the fluid dynamic variables. The level set function is used to track the free surface evolution; dynamic boundary conditions are enforced directly on the interface. This approach allows to accurately predict the evolution of the free surface even in the presence of violent breaking waves phenomena, maintaining the interface sharp, without any need to smear out the fluid properties across the two phases. This paper is aimed at the prediction of the complex free-surface flow field generated by a deep-V planing boat at medium and high Froude numbers (from 0.6 up to 1.2). In the present work, the planing hull is treated as a two-degree-of-freedom rigid object. Flow field is characterized by the presence of thin water sheets, several energetic breaking waves and plungings. The computational results include convergence of the trim angle, sinkage and resistance under grid refinement; high-quality experimental data are used for the purposes of validation, allowing to

  17. Unprecedented Al supersaturation in single-phase rock salt structure VAlN films by Al+ subplantation

    Science.gov (United States)

    Greczynski, G.; Mráz, S.; Hans, M.; Primetzhofer, D.; Lu, J.; Hultman, L.; Schneider, J. M.

    2017-05-01

    Modern applications of refractory ceramic thin films, predominantly as wear-protective coatings on cutting tools and on components utilized in automotive engines, require a combination of excellent mechanical properties, thermal stability, and oxidation resistance. Conventional design approaches for transition metal nitride coatings with improved thermal and chemical stability are based on alloying with Al. It is well known that the solubility of Al in NaCl-structure transition metal nitrides is limited. Hence, the great challenge is to increase the Al concentration substantially while avoiding precipitation of the thermodynamically favored wurtzite-AlN phase, which is detrimental to mechanical properties. Here, we use VAlN as a model system to illustrate a new concept for the synthesis of metastable single-phase NaCl-structure thin films with the Al content far beyond solubility limits obtained with conventional plasma processes. This supersaturation is achieved by separating the film-forming species in time and energy domains through synchronization of the 70-μs-long pulsed substrate bias with intense periodic fluxes of energetic Al+ metal ions during reactive hybrid high power impulse magnetron sputtering of the Al target and direct current magnetron sputtering of the V target in the Ar/N2 gas mixture. Hereby, Al is subplanted into the cubic VN grains formed by the continuous flux of low-energy V neutrals. We show that Al subplantation enables an unprecedented 42% increase in metastable Al solubility limit in V1-xAlxN, from x = 0.52 obtained with the conventional method to 0.75. The elastic modulus is 325 ± 5 GPa, in excellent agreement with density functional theory calculations, and approximately 50% higher than for corresponding films grown by dc magnetron sputtering. The extension of the presented strategy to other Al-ion-assisted vapor deposition methods or materials systems is straightforward, which opens up the way for producing supersaturated single-phase

  18. Modeling the Real-Time use of Reserves in the Joint Energy and Reserve Hourly Scheduling of a Pumped Storage Plant

    OpenAIRE

    Chazarra, Manuel; Perez-Diaz, Juan I.; Garcia-Gonzàles, Javier; Helseth, Arild

    2016-01-01

    - This paper studies the impact that different approaches of modeling the real-time use of the secondary regulation reserves have in the joint energy and reserve hourly scheduling of a price-taker pumped-storage hydropower plant. The unexpected imbalance costs due to the error between the forecasted real-time use of the reserves and the actual value are also studied and evaluated for the different approaches. The proposed methodology is applied to a daily-cycle and closed-loop pumped-stora...

  19. MODELLING OF PROCESS OF COMPRESSION OF STEAMS OF A RECTIFIED ALCOHOL IN THE SCHEMA OF AN ALCOHOLIC COLUMN WITH A HEAT PUMP

    Directory of Open Access Journals (Sweden)

    T. G. Korotkova

    2012-01-01

    Full Text Available The use of thermodynamic relations and equation of state of Redlich-Kwong, obtaining the approximation of the molar volume dependence on temperature and pressure, ideal gas heat capacity on temperature for the modeling of vapor compression rectified alcohol. Energy analysis scheme alcohol column with a heat pump and its comparison with the standard rectification plant.

  20. Performance analysis of the Single-Phase Grid-Connected Inverter of a photovoltaic system in water and wind applications

    Directory of Open Access Journals (Sweden)

    Borkowski Dariusz

    2016-01-01

    Full Text Available Single-phase grid connected inverters are nowadays broadly developed and tested in various types of applications especially in photovoltaic systems. The main aim of the inverter control strategy is to extract the maximum energy from the PV system which corresponds to the maximum power at certain conditions. However, the MPPT methods are also important in other renewable energy conversion systems. This paper analyses the performance of a commercially available photovoltaic inverter in water and wind systems. Presented models are implemented in a laboratory test bench in the form of torque characteristics realised by an induction motor fed by the inverter with vector control. The parameters are scaled into relative variables to provide a proper performance comparison. Presented tests include step response to assess the performance of a system dynamic. The dynamic tests showed a fast response of the investigated systems. The MPPT tracking accuracy tested under realistic profiles is similar for both cases: 98% and 96% respectively for the wind and water systems. These results prove the satisfactory performance of the MPPT of the PV microinverter in these applications.

  1. General correlations for pressure drop and heat transfer for single-phase turbulent flow in internally ribbed tubes

    International Nuclear Information System (INIS)

    Ravigururajan, T.S.; Bergles, A.E.

    1985-01-01

    General correlations for friction factors and heat transfer coefficients for single-phase turbulent flow in internally ribbed tubes are presented. Data from previous investigations are gathered for a wide range of tube parameters with e/d: 0.01 to 0.2; p/d: 0.1 to 7.0; α/90: 0.3 to 1.0, and flow parameters Re: 5000 to 250,000 and Pr: 0.66 to 37.6. The data were applied to a linear model to get normalized correlations that were then modified to fit tubes with extremely small parametric values. A shape function was included in the friction correlation to account for different rib profiles. The friction correlation predicts 96% of the data base to within +. 50% and 77% of the data base to within +. 20%. Corresponding figures for the heat transfer correlation are 99% and 69%. The present correlations are superior, for this extensive data base, to those presented by other investigators

  2. Single-phase liquid flow forced convection under a nearly uniform heat flux boundary condition in microchannels

    KAUST Repository

    Lee, Man

    2012-02-22

    A microchannel heat sink, integrated with pressure and temperature microsensors, is utilized to study single-phase liquid flow forced convection under a uniform heat flux boundary condition. Utilizing a waferbond-and-etch- back technology, the heat source, temperature and pressure sensors are encapsulated in a thin composite membrane capping the microchannels, thus allowing experimentally good control of the thermal boundary conditions. A three-dimensional physical model has been constructed to facilitate numerical simulations of the heat flux distribution. The results indicate that upstream the cold working fluid absorbs heat, while, within the current operating conditions, downstream the warmer working fluid releases heat. The Nusselt number is computed numerically and compared with experimental and analytical results. The wall Nusselt number in a microchannel can be estimated using classical analytical solutions only over a limited range of the Reynolds number, Re: both the top and bottom Nusselt numbers approach 4 for Re < 1, while the top and bottom Nusselt numbers approach 0 and 5.3, respectively, for Re > 100. The experimentally estimated Nusselt number for forced convection is highly sensitive to the location of the temperature measurements used in calculating the Nusselt number. © 2012 IOP Publishing Ltd.

  3. Development of a single-phase 330kVA HTS transformer using GdBCO tapes

    Science.gov (United States)

    Hu, Daoyu; Li, Zhuyong; Hong, Zhiyong; Jin, Zhijian

    2017-08-01

    With the mature of manufacture process and technology of high temperature superconductors, the critical current and stability are gradually increased. High temperature superconductors could be used in transformer, current limiter, generator, magnet and etc. This paper focuses on development and characteristic tests of a single-phase high temperature superconducting (HTS) power transformer with capacity of 330 kVA by using GdBCO tapes, which is 1/3 model of a 1 MVA / 10 kV / 0.4 kV HTS transformer. The specifications of iron core, HTS windings and cryostat are described in detail. The iron core is made of silicon steel plate. The arrangement of HTS windings are based on experimental and simulated results. The cryostat with a room temperature bore is manufactured using nonmetallic materials. Several characteristic tests and insulation tests are performed in liquid nitrogen of 77 K. The efficiency and AC loss at rated load is 99.90% and 243.7 W, respectively. In addition, an overload test was also performed.

  4. Experimental validation of a theoretical model for a direct-expansion solar-assisted heat pump applied to heating

    International Nuclear Information System (INIS)

    Moreno-Rodriguez, A.; Garcia-Hernando, N.; González-Gil, A.; Izquierdo, M.

    2013-01-01

    This paper discusses the experimental validation of a theoretical model that determines the operating parameters of a DXSAHP (direct-expansion solar-assisted heat pump) applied to heating. For this application, the model took into account the variable condensing temperature, and it was developed from the following environmental variables: outdoor temperature, solar radiation and wind. The experimental data were obtained from a prototype installed at the University Carlos III, which is located south of Madrid. The prototype uses a solar collector with a total area of 5.6 m 2 , a compressor with a rated capacity of 1100 W, a thermostatic expansion valve and fan-coil units as indoor terminals. The monitoring results were analyzed for several typical days in the climatic zone where the machine was located to understand the equipment's seasonal behavior. The experimental coefficient of the performance varies between 1.9 and 2.7, and the equipment behavior in extreme outdoor conditions has also been known to determine the thermal demand that can be compensated for. - Highlights: • The study aims to present an experimental validation of a theoretical model. • The experimental COP can vary between 1.9 and 2.7 (max. condensation temperature 59 °C). • A “dragging term” relates condensation and evaporation temperature. • The operating parameters respond to the solar radiation. The COP may increase up to 25%

  5. Hydrodynamic Effects on Modeling and Control of a High Temperature Active Magnetic Bearing Pump with a Canned Rotor

    Energy Technology Data Exchange (ETDEWEB)

    Melin, Alexander M [ORNL; Kisner, Roger A [ORNL; Fugate, David L [ORNL; Holcomb, David Eugene [ORNL

    2015-01-01

    Embedding instrumentation and control Embedding instrumentation and control (I\\&C) at the component level in nuclear power plants can improve component performance, lifetime, and resilience by optimizing operation, reducing the constraints on physical design, and providing on-board prognostics and diagnostics. However, the extreme environments that many nuclear power plant components operate in makes embedding instrumentation and control at the component level difficult. Successfully utilizing embedded I\\&C requires developing a deep understanding of the system's dynamics and using that knowledge to overcome material and physical limitations imposed by the environment. In this paper, we will develop a coupled dynamic model of a high temperature (700 $^\\circ$C) canned rotor pump that incorporates rotordynamics, hydrodynamics, and active magnetic bearing dynamics. Then we will compare two control design methods, one that uses a simplified decoupled model of the system and another that utilizes the full coupled system model. It will be seen that utilizing all the available knowledge of the system dynamics in the controller design yield an order of magnitude improvement in the magnitude of the magnetic bearing response to disturbances at the same level of control effort, a large reduction in the settling time of the system, and a smoother control action.

  6. Impact of two-stage turbocharging architectures on pumping losses of automotive engines based on an analytical model

    International Nuclear Information System (INIS)

    Galindo, J.; Serrano, J.R.; Climent, H.; Varnier, O.

    2010-01-01

    Present work presents an analytical study of two-stage turbocharging configuration performance. The aim of this work is to understand the influence of different two-stage-architecture parameters to optimize the use of exhaust manifold gases energy and to aid decision making process. An analytical model giving the relationship between global compression ratio and global expansion ratio is developed as a function of basic engine and turbocharging system parameters. Having an analytical solution, the influence of different variables, such as expansion ratio between HP and LP turbine, intercooler efficiency, turbochargers efficiency, cooling fluid temperature and exhaust temperature are studied independently. Engine simulations with proposed analytical model have been performed to analyze the influence of these different parameters on brake thermal efficiency and pumping mean effective pressure. The results obtained show the overall performance of the two-stage system for the whole operative range and characterize the optimum control of the elements for each operative condition. The model was also used to compare single-stage and two-stage architectures performance for the same engine operative conditions. Benefits and limits in terms of breathing capabilities and brake thermal efficiency of each type of system have been presented and analyzed.

  7. An efficient model for predicting mixing lengths in serial pumping of petroleum products

    Energy Technology Data Exchange (ETDEWEB)

    Baptista, Renan Martins [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil). Centro de Pesquisas. Div. de Explotacao]. E-mail: renan@cenpes.petrobras.com.br; Rachid, Felipe Bastos de Freitas [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Engenharia Mecanica]. E-mail: rachid@mec.uff.br; Araujo, Jose Henrique Carneiro de [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Ciencia da Computacao]. E-mail: jhca@dcc.ic.uff.br

    2000-07-01

    This paper presents a new model for estimating mixing volumes which arises in batching transfers in multi product pipelines. The novel features of the model are the incorporation of the flow rate variation with time and the use of a more precise effective dispersion coefficient, which is considered to depend on the concentration. The governing equation of the model forms a non linear initial value problem that is solved by using a predictor corrector finite difference method. A comparison among the theoretical predictions of the proposed model, a field test and other classical procedures show that it exhibits the best estimate over the whole range of admissible concentrations investigated. (author)

  8. Pumping behavior of sputter ion pumps

    International Nuclear Information System (INIS)

    Chou, T.S.; McCafferty, D.

    The ultrahigh vacuum requirements of ISABELLE is obtained by distributed pumping stations. Each pumping station consists of 1000 l/s titanium sublimation pump for active gases (N 2 , H 2 , O 2 , CO, etc.), and a 20 l/s sputter ion pump for inert gases (methane, noble gases like He, etc.). The combination of the alarming production rate of methane from titanium sublimation pumps (TSP) and the decreasing pumping speed of sputter ion pumps (SIP) in the ultrahigh vacuum region (UHV) leads us to investigate this problem. In this paper, we first describe the essential physics and chemistry of the SIP in a very clean condition, followed by a discussion of our measuring techniques. Finally measured methane, argon and helium pumping speeds are presented for three different ion pumps in the range of 10 -6 to 10 -11 Torr. The virtues of the best pump are also discussed

  9. Structure based classification for bile salt export pump (BSEP) inhibitors using comparative structural modeling of human BSEP

    Science.gov (United States)

    Jain, Sankalp; Grandits, Melanie; Richter, Lars; Ecker, Gerhard F.

    2017-06-01

    The bile salt export pump (BSEP) actively transports conjugated monovalent bile acids from the hepatocytes into the bile. This facilitates the formation of micelles and promotes digestion and absorption of dietary fat. Inhibition of BSEP leads to decreased bile flow and accumulation of cytotoxic bile salts in the liver. A number of compounds have been identified to interact with BSEP, which results in drug-induced cholestasis or liver injury. Therefore, in silico approaches for flagging compounds as potential BSEP inhibitors would be of high value in the early stage of the drug discovery pipeline. Up to now, due to the lack of a high-resolution X-ray structure of BSEP, in silico based identification of BSEP inhibitors focused on ligand-based approaches. In this study, we provide a homology model for BSEP, developed using the corrected mouse P-glycoprotein structure (PDB ID: 4M1M). Subsequently, the model was used for docking-based classification of a set of 1212 compounds (405 BSEP inhibitors, 807 non-inhibitors). Using the scoring function ChemScore, a prediction accuracy of 81% on the training set and 73% on two external test sets could be obtained. In addition, the applicability domain of the models was assessed based on Euclidean distance. Further, analysis of the protein-ligand interaction fingerprints revealed certain functional group-amino acid residue interactions that could play a key role for ligand binding. Though ligand-based models, due to their high speed and accuracy, remain the method of choice for classification of BSEP inhibitors, structure-assisted docking models demonstrate reasonably good prediction accuracies while additionally providing information about putative protein-ligand interactions.

  10. Electroporation-mediated in vivo gene delivery of the Na+/K+-ATPase pump reduced lung injury in a mouse model of lung contusion.

    Science.gov (United States)

    Machado-Aranda, David A; Suresh, M V; Yu, Bi; Raghavendran, Krishnan

    2012-01-01

    Lung contusion (LC) is an independent risk factor for acute respiratory distress syndrome. The final common pathway in ARDS involves accumulation of fluid in the alveoli. In this study, we demonstrate the application of a potential gene therapy approach by delivering the Na+/K+-ATPase pump subunits in a murine model of LC. We hypothesized that restoring the activity of the pump will result in removal of excess alveolar fluid and additionally reduce inflammation. Under anesthesia, C57/BL6 mice were struck along the right posterior axillary line 1 cm above the costal margin with a cortical contusion impactor. Immediately afterward, 100 μg of plasmid DNA coding for the α,β of the Na+/K+-ATPase pump were instilled into the lungs (LC-electroporation-pump group). Contusion only (LC-only) and a sham saline instillation group after contusion were used as controls (LC-electroporation-sham). By using a BTX 830 electroporator, eight electrical pulses of 200 V/cm field strength were applied transthoracically. Mice were killed at 24 hours, 48 hours, and 72 hours after delivery. Bronchial alveolar lavage was recollected to measure albumin and cytokines by enzyme-linked immunosorbent assay. Pulmonary compliance was measured, and lungs were subject to histopathologic analysis. After the electroporation and delivery of genes coding for the α,β subunits of the Na+/K+-ATPase pump, there was a significant mitigation of acute lung injury as evidenced by reduction in bronchial alveolar lavage levels of albumin, improved pressure volume curves, and reduced inflammation seen on histology. Electroporation-mediated gene transfer of the subunits of the Na+/K+-ATPase pump enhanced recovery from acute inflammatory lung injury after LC.

  11. ENERGY STAR Certified Pool Pumps

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 1.1 ENERGY STAR Program Requirements for Pool Pumps that are effective as of February 15,...

  12. Numerical groundwater-flow modeling to evaluate potential effects of pumping and recharge: implications for sustainable groundwater management in the Mahanadi delta region, India

    Science.gov (United States)

    Sahoo, Sasmita; Jha, Madan K.

    2017-12-01

    Process-based groundwater models are useful to understand complex aquifer systems and make predictions about their response to hydrological changes. A conceptual model for evaluating responses to environmental changes is presented, considering the hydrogeologic framework, flow processes, aquifer hydraulic properties, boundary conditions, and sources and sinks of the groundwater system. Based on this conceptual model, a quasi-three-dimensional transient groundwater flow model was designed using MODFLOW to simulate the groundwater system of Mahanadi River delta, eastern India. The model was constructed in the context of an upper unconfined aquifer and lower confined aquifer, separated by an aquitard. Hydraulic heads of 13 shallow wells and 11 deep wells were used to calibrate transient groundwater conditions during 1997-2006, followed by validation (2007-2011). The aquifer and aquitard hydraulic properties were obtained by pumping tests and were calibrated along with the rainfall recharge. The statistical and graphical performance indicators suggested a reasonably good simulation of groundwater flow over the study area. Sensitivity analysis revealed that groundwater level is most sensitive to the hydraulic conductivities of both the aquifers, followed by vertical hydraulic conductivity of the confining layer. The calibrated model was then employed to explore groundwater-flow dynamics in response to changes in pumping and recharge conditions. The simulation results indicate that pumping has a substantial effect on the confined aquifer flow regime as compared to the unconfined aquifer. The results and insights from this study have important implications for other regional groundwater modeling studies, especially in multi-layered aquifer systems.

  13. Experimental Results and Model Calculations of a Hybrid Adsorption-Compression Heat Pump Based on a Roots Compressor and Silica Gel-Water Sorption

    Energy Technology Data Exchange (ETDEWEB)

    Van der Pal, M.; De Boer, R.; Wemmers, A.K.; Smeding, S.F.; Veldhuis, J.B.J.; Lycklama a Nijeholt, J.A.

    2013-10-15

    Thermally driven sorption systems can provide significant energy savings, especially in industrial applications. The driving temperature for operation of such systems limits the operating window and can be a barrier for market-introduction. By adding a compressor, the sorption cycle can be run using lower waste heat temperatures. ECN has recently started the development of such a hybrid heat pump. The final goal is to develop a hybrid heat pump for upgrading lower (<100C) temperature industrial waste heat to above pinch temperatures. The paper presents the first measurements and model calculations of a hybrid heat pump system using a water-silica gel system combined with a Roots type compressor. From the measurements can be seen that the effect of the compressor is dependent on where in the cycle it is placed. When placed between the evaporator and the sorption reactor, it has a considerable larger effect compared to the compressor placed between the sorption reactor and the condenser. The latter hardly improves the performance compared to purely heat-driven operation. This shows the importance of studying the interaction between all components of the system. The model, which shows reasonable correlation with the measurements, could proof to be a valuable tool to determine the optimal hybrid heat pump configuration.

  14. Blasting Damage Predictions by Numerical Modeling in Siahbishe Pumped Storage Powerhouse

    Science.gov (United States)

    Eslami, Majid; Goshtasbi, Kamran

    2017-04-01

    One of the popular methods of underground and surface excavations is the use of blasting. Throughout this method of excavation, the loading resulted from blasting can be affected by different geo-mechanical and structural parameters of rock mass. Several factors affect turbulence in underground structures some of which are explosion, vibration, and stress impulses caused by the neighbouring blasting products. In investigating the blasting mechanism one should address the processes which expand with time and cause seismic events. To protect the adjoining structures against any probable deconstruction or damage, it is very important to model the blasting process prior to any actual operation. Efforts have been taken in the present study to demonstrate the potentiality of numerical methods in predicting the specified parameters in order to prevent any probable destruction. For this purpose the blasting process was modeled, according to its natural implementation, in one of the tunnels of Siahbishe dam by the 3DEC and AUTODYN 3D codes. 3DEC was used for modeling the blasting environment as well as the blast holes and AUTODYN 3D for modeling the explosion process in the blast hole. In this process the output of AUTODYN 3D, which is a result of modeling the blast hole and is in the form of stress waves, is entered into 3DEC. For analyzing the amount of destruction made by the blasting operation, the key parameter of Peak Particle Velocity was used. In the end, the numerical modeling results have been compared with the data recorded by the seismographs planted through the tunnel. As the results indicated 3DEC and AUTODYN 3D proved appropriate for analyzing such an issue. Therefore, by means of these two softwares one can analyze explosion processes prior to their implementation and make close estimation of the damage resulting from these processes.

  15. Power Based Phase-Locked Loop Under Adverse Conditions with Moving Average Filter for Single-Phase System

    OpenAIRE

    Menxi Xie; CanYan Zhu; BingWei Shi; Yong Yang

    2017-01-01

    High performance synchronization methord is citical for grid connected power converter. For single-phase system, power based phase-locked loop(pPLL) uses a multiplier as phase detector(PD). As single-phase grid voltage is distorted, the phase error information contains ac disturbances oscillating at integer multiples of fundamental frequency which lead to detection error. This paper presents a new scheme based on moving average filter(MAF) applied in-loop of pPLL. The signal characteristic of...

  16. Reliability-Oriented Design and Analysis of Input Capacitors in Single-Phase Transformer-less Photovoltaic Inverters

    DEFF Research Database (Denmark)

    Wang, Huai; Yang, Yongheng; Blaabjerg, Frede

    2013-01-01

    . A reliability-oriented design guideline is proposed in this paper for the input capacitors in single-phase transformer-less PV inverters. The guideline ensures that the service time requirement is to be accomplished under different power levels and ambient temperature profiles. The theoretical analysis has been......While 99% efficiency has been reported, the target of 20 years of service time imposes new challenge to cost-effective solutions for grid-connected photovoltaic (PV) inverters. Aluminum electrolytic capacitors are the weak-link in terms of reliability and lifetime in single-phase PV systems...

  17. Thermal Optimized Operation of the Single-Phase Full-Bridge PV Inverter under Low Voltage Ride-Through Mode

    DEFF Research Database (Denmark)

    Wang, Huai; Yang, Yongheng; Blaabjerg, Frede

    2013-01-01

    . At the same time, the target of a long service time (25 years or more) imposes new challenges to grid-connected transformer-less PV systems. Achieving more reliable PV inverters is of intense interest in recent research. As one of the most critical stresses that induce failures, the thermal stresses...... on the power devices of a single-phase full-bridge PV inverter are analyzed in different operational modes in this paper. The low voltage grid condition is specially taken into account in this paper. The analysis is demonstrated by a 3 kW single-phase full-bridge grid-connected PV system by simulations...

  18. Lifetime Estimation of DC-link Capacitors in a Single-phase Converter with an Integrated Active Power Decoupling Module

    DEFF Research Database (Denmark)

    Ma, Siyuan; Wang, Haoran; Tang, Junchaojie

    2016-01-01

    In single-phase inverters, DC-link capacitors are installed at the DC-link to buffer the ripple power between the AC side and DC side. Active decoupling methods introduce additional circuits at the DC side or AC side to partially or fully supply the ripple power. So that the demanded DC-link capa......In single-phase inverters, DC-link capacitors are installed at the DC-link to buffer the ripple power between the AC side and DC side. Active decoupling methods introduce additional circuits at the DC side or AC side to partially or fully supply the ripple power. So that the demanded DC...

  19. Pump characteristics and applications

    CERN Document Server

    Volk, Michael

    2013-01-01

    Providing a wealth of information on pumps and pump systems, Pump Characteristics and Applications, Third Edition details how pump equipment is selected, sized, operated, maintained, and repaired. The book identifies the key components of pumps and pump accessories, introduces the basics of pump and system hydraulics as well as more advanced hydraulic topics, and details various pump types, as well as special materials on seals, motors, variable frequency drives, and other pump-related subjects. It uses example problems throughout the text, reinforcing the practical application of the formulae

  20. Wind power integration with heat pumps, heat storages, and electric vehicles – Energy systems analysis and modelling

    DEFF Research Database (Denmark)

    Hedegaard, Karsten

    The fluctuating and only partly predictable nature of wind challenges an effective integration of large wind power penetrations. This PhD thesis investigates to which extent heat pumps, heat storages, and electric vehicles can support the integration of wind power. Considering the gaps in existing...... in an energy system context. Energy systems analyses reveal that the heat pumps can even without flexible operation contribute significantly to facilitating larger wind power investments and reducing system costs, fuel consumption, and CO2 emissions. When equipping the heat pumps with heat storages, only...... moderate additional benefits are achieved. Hereof, the main benefit is that the need for investing in peak/reserve capacities can be reduced through peak load shaving. It is more important to ensure flexible operation of electric vehicles than of individual heat pumps, due to differences in the load...