WorldWideScience

Sample records for single-pass flow-through experiments

  1. Uranium Release from Acidic Weathered Hanford Sediments: Single-Pass Flow-Through and Column Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Guohui [Pacific Northwest National Laboratory, Richland, Washington 99354, United States; Um, Wooyong [Pacific Northwest National Laboratory, Richland, Washington 99354, United States; Pohang University of Science and Technology (POSTECH), Pohang, South Korea; Wang, Zheming [Pacific Northwest National Laboratory, Richland, Washington 99354, United States; Reinoso-Maset, Estela [Sierra; Washton, Nancy M. [Pacific Northwest National Laboratory, Richland, Washington 99354, United States; Mueller, Karl T. [Pacific Northwest National Laboratory, Richland, Washington 99354, United States; Perdrial, Nicolas [Department; Department; O’Day, Peggy A. [Sierra; Chorover, Jon [Department

    2017-09-21

    The reaction of acidic radioactive waste with sediments can induce mineral transformation reactions that, in turn, control contaminant fate. Here, sediment weathering by synthetic uranium-containing acid solutions was investigated using bench-scale experiments to simulate waste disposal conditions at Hanford’s cribs, USA. During acid weathering, the presence of phosphate exerted a strong influence over uranium mineralogy and a rapidly precipitated, crystalline uranium phosphate phase (meta-ankoleite [K(UO2)(PO4)·3H2O]) was identified using spectroscopic and diffraction-based techniques. In phosphate-free system, uranium oxyhydroxide minerals such as K-compreignacite [K2(UO2)6O4(OH)6·7H2O] were formed. Single-pass flow-through (SPFT) and column leaching experiments using synthetic Hanford pore water showed that uranium precipitated as meta-ankoleite during acid weathering was strongly retained in the sediments, with an average release rate of 2.67E-12 mol g-1 s-1. In the absence of phosphate, uranium release was controlled by dissolution of uranium oxyhydroxide (compreignacite-type) mineral with a release rate of 1.05-2.42E-10 mol g-1 s-1. The uranium mineralogy and release rates determined for both systems in this study support the development of accurate U-release models for prediction of contaminant transport. These results suggest that phosphate minerals may be a good candidate for uranium remediation approaches at contaminated sites.

  2. FY2016 ILAW Glass Corrosion Testing with the Single-Pass Flow-Through Method

    Energy Technology Data Exchange (ETDEWEB)

    Neeway, James J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Asmussen, Robert M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Parruzot, Benjamin PG [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Cordova, Elsa [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Williams, Benjamin D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Leavy, Ian I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Stephenson, John R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); McElroy, Erin M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-04-21

    The inventory of immobilized low-activity waste (ILAW) produced at the Hanford Tank Waste Treatment and Immobilization Plant (WTP) will be disposed of at the near-surface, on-site Integrated Disposal Facility (IDF). When groundwater comes into contact with the waste form, the glass will corrode and radionuclides will be released into the near-field environment. Because the release of the radionuclides is dependent on the dissolution rate of the glass, it is important that the performance assessment (PA) model accounts for the dissolution rate of the glass as a function of various chemical conditions. To accomplish this, an IDF PA model based on Transition State Theory (TST) can be employed. The model is able to account for changes in temperature, exposed surface area, and pH of the contacting solution as well as the effect of silicon concentrations in solution, specifically the activity of orthosilicic acid (H4SiO4), whose concentration is directly linked to the glass dissolution rate. In addition, the IDF PA model accounts for the alkali-ion exchange process as sodium is leached from the glass and into solution. The effect of temperature, pH, H4SiO4 activity, and the rate of ion-exchange can be parameterized and implemented directly into the PA rate law model. The rate law parameters are derived from laboratory tests with the single-pass flow-through (SPFT) method. To date, rate law parameters have been determined for seven ILAW glass compositions, thus additional rate law parameters on a wider range of compositions will supplement the existing body of data for PA maintenance activities. The data provided in this report can be used by ILAW glass scientists to further the understanding of ILAW glass behavior, by IDF PA modelers to use the rate law parameters in PA modeling efforts, and by Department of Energy (DOE) contractors and decision makers as they assess the IDF PA program.

  3. Milestone experiments for single pass UV/X-ray FELs

    International Nuclear Information System (INIS)

    Ben-Zvi, I.

    1994-01-01

    In the past decade, significant advances have been made in the theory and technology of high brightness electron beams and single pass FELS. These developments facilitate the construction of practical UV and X-ray FELs and has prompted proposals to the DOE for the construction of such facilities. There are several important experiments to be performed before committing to the construction of dedicated user facilities. Two experiments are under construction in the IR, the UCLA Self Amplified Spontaneous Emission experiment and the BNL laser seeded Harmonic Generation experiment. A multi-institution collaboration is being organized about a 210 MeV electron linac available at BNL and the 10 meter tong NISUS wiggler. This experiment will be done in the UV and will test various experimental aspects of electron beam dynamics, FEL exponential regime with gain guiding, start up from noise, seeding and harmonic generation. These experiments will advance the state of FEL research and lead towards future dedicated users' facilities

  4. Standard practice for measurement of the glass dissolution rate using the single-pass flow-through test method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This practice describes a single-pass flow-through (SPFT) test method that can be used to measure the dissolution rate of a homogeneous silicate glass, including nuclear waste glasses, in various test solutions at temperatures less than 100°C. Tests may be conducted under conditions in which the effects from dissolved species on the dissolution rate are minimized to measure the forward dissolution rate at specific values of temperature and pH, or to measure the dependence of the dissolution rate on the concentrations of various solute species. 1.2 Tests are conducted by pumping solutions in either a continuous or pulsed flow mode through a reaction cell that contains the test specimen. Tests must be conducted at several solution flow rates to evaluate the effect of the flow rate on the glass dissolution rate. 1.3 This practice excludes static test methods in which flow is simulated by manually removing solution from the reaction cell and replacing it with fresh solution. 1.4 Tests may be conducted wit...

  5. Evaluation of the single-pass flow-through test to support a low-activity waste specification

    International Nuclear Information System (INIS)

    McGrail, B.P.; Peeler, D.K.

    1995-09-01

    A series of single-pass flow-through (SPFT) tests was performed on five reference low-activity waste glasses and a reference glass from the National Institute of Standards and Technology to support a product specification for low-activity waste (LAW) forms. The results showed that the SPFT test provides a means to quantitatively distinguish among LAW glass forms in terms of their forward reaction rate at a given temperature and solution pH. Two of the test glasses were also subjected to SPFT testing at Argonne National Laboratory (ANL). Forward reaction rate constants calculated from the ANL test data were 100 to over 1,000 times larger than the values obtained from the SPFT tests conducted at PNL. An analysis of the ANL results showed that they were inconsistent with independent measurements done on glasses of similar composition, the known pH-dependence of the forward rate, and with the results from low surface-area-to-volume, short duration product consistency tests. Because the data set obtained from the SPFT tests done at PNL was consistent with each of these same factors, a detailed examination of the test procedures used at both laboratories was performed to determine the cause(s) of the discrepancy. The omission of background subtraction in the data analysis procedure and the short-duration (on the order of hours) of the ANL tests are factors that may have significantly affected the calculated rates

  6. Milestone experiments for single pass UV/X-ray FELs

    Science.gov (United States)

    Ben-Zvi, Ilan

    1995-04-01

    In the past decade, significant advances have been made in the theory and technology of high brightness electron beams and single pass FELs. These developments facilitate the construction of practical UV and X-ray FELs and has prompted proposals to the DOE for the construction of such facilities. There are several important experiments to be performed before committing to the construction of dedicated user facilities. Two experiments are under construction in the IR, the UCLA self-amplified spontaneous emission experiment and the BNL laser seeded harmonic generation experiment. A multi-institution collaboration is being organized about a 210 MeV electron linac available at BNL and the 10 m long NISUS wiggler. This experiment will be done in the UV and will test various experimental aspects of electron beam dynamics, FEL exponential regime with gain guiding, start-up from noise, seeding and harmonic generation. These experiments will advance the state of FEL research and lead towards future dedicated users' facilities.

  7. Single-Pass Percutaneous Liver Biopsy for Diffuse Liver Disease Using an Automated Device: Experience in 154 Procedures

    International Nuclear Information System (INIS)

    Rivera-Sanfeliz, Gerant; Kinney, Thomas B.; Rose, Steven C.; Agha, Ayad K.M.; Valji, Karim; Miller, Franklin J.; Roberts, Anne C.

    2005-01-01

    Purpose: To describe our experience with ultrasound (US)-guided percutaneous liver biopsies using the INRAD 18G Express core needle biopsy system.Methods: One hundred and fifty-four consecutive percutaneous core liver biopsy procedures were performed in 153 men in a single institution over 37 months. The medical charts, pathology reports, and radiology files were retrospectively reviewed. The number of needle passes, type of guidance, change in hematocrit level, and adequacy of specimens for histologic analysis were evaluated.Results: All biopsies were performed for histologic staging of chronic liver diseases. The majority of patients had hepatitis C (134/153, 90.2%). All patients were discharged to home after 4 hr of postprocedural observation. In 145 of 154 (94%) biopsies, a single needle pass was sufficient for diagnosis. US guidance was utilized in all but one of the procedures (153/154, 99.4%). The mean hematocrit decrease was 1.2% (44.1-42.9%). Pain requiring narcotic analgesia, the most frequent complication, occurred in 28 of 154 procedures (18.2%). No major complications occurred. The specimens were diagnostic in 152 of 154 procedures (98.7%).Conclusions: Single-pass percutaneous US-guided liver biopsy with the INRAD 18G Express core needle biopsy system is safe and provides definitive pathologic diagnosis of chronic liver disease. It can be performed on an outpatient basis. Routine post-biopsy monitoring of hematocrit level in stable, asymptomatic patients is probably not warranted

  8. Development of a Single-Pass Amplifier for an Optical Stochastic Cooling Proof-of-Principle Experiment at Fermilab's IOTA Facility

    Energy Technology Data Exchange (ETDEWEB)

    Andorf, M. B. [NICADD, DeKalb; Lebedev, V. A. [Fermilab; Piot, P. [NIU, DeKalb

    2015-06-01

    Optical stochastic cooling (OSC) is a method of beam cooling which is expected to provide cooling rates orders of magnitude larger than ordinary stochastic cooling. Light from an undulator (the pickup) is amplified and fed back onto the particle beam via another undulator (the kicker). Fermilab is currently exploring a possible proof-of-principle experiment of the OSC at the integrable-optics test accelerator (IOTA) ring. To implement effective OSC a good correction of phase distortions in the entire band of the optical amplifier is required. In this contribution we present progress in experimental characterization of phase distortions associated to a Titanium Sapphire crystal laser-gain medium (a possible candidate gain medium for the OSC experiment to be performed at IOTA). We also discuss a possible option for a mid-IR amplifier

  9. EMISAR single pass topographic SAR interferometer modes

    DEFF Research Database (Denmark)

    Madsen, Søren Nørvang; Skou, Niels; Woelders, Kim

    1996-01-01

    The Danish Center for Remote Sensing (DCRS) has augmented its dual-frequency polarimetric synthetic aperture radar system (EMISAR) with single pass across-track interferometric (XTI) modes. This paper describes the system configuration, specifications and the operating modes. Analysis of data acq...

  10. Single Pass Albumin Dialysis in Hepatorenal Syndrome

    Directory of Open Access Journals (Sweden)

    Rahman Ebadur

    2008-01-01

    Full Text Available Hepatorenal syndrome (HRS is the most appalling complication of acute or chronic liver disease with 90% mortality rate. Single pass albumin dialysis (SPAD can be considered as a noble liver support technique in HRS. Here, we present a case of a young healthy patient who developed hyperacute fulminant liver failure that progressed to HRS. The patient was offered SPAD as a bridge to liver transplantation, however, it resulted in an excellent recovery.

  11. Flow-through column experiments to determine the geochemical behavior of common hydrological tracers

    Science.gov (United States)

    Moola, P. S. N.; Sigfússon, B.; Stefansson, A.

    2015-12-01

    Tracer testing is one of the most effective methods used to study groundwater flow, reservoir characteristics and subsurface properties in geohydrology. Hydrological tracer tests were conducted with the basic assumption that the tracer is chemically inert and non-reactive. However, not all tracers behave non-reactive at different pH conditions, the particular tracer may interact with mineral surfaces in the reservoir. In order to study the geochemical behavior of some common hydrological tracers flow-through column experiments were conducted at 25°C. Six common hydrological tracers were investigated, amino G acid, fluorescein, napthionic acid, pyranine, rhodamine B and rhodamine G in porous rocks consisting of basaltic glass, quartz or rhyolite at pH 3, 6.5 and 9. Homogenous porous material of fixed grain size 45-125μm were dry packed in the column to conduct flow through column experiments. Tracers were pumped at fixed flow rates for 20 minutes and switched back to experimental blank solution and the tracer concentration monitored at the outlet. The measured break-through tracer curves were compared to theoretical 1-D reactive transport simulations calculated using the PHREEQC program (Parkhurst and Appelo, 1999). The data obtained from the breakthrough curves suggest that the tracers may be reactive, non-reactive and partially reactive depending on the rock type and solution pH. The tracers that were observed to be reactive showed the influence of adsorption and desorption. The results suggest that some tracers commonly used in ground water hydrology are not suitable under all conditions as they may react with the rocks of the groundwater system.

  12. Global warming: Design of a flow-through shallow lake mesocosm climate experiment

    DEFF Research Database (Denmark)

    Liboriussen, L.; Landkildehus, F.; Meerhoff, M.

    2005-01-01

    design details, operating characteristics, and background information on a currently operating experimental flow-through mesocosm system that allows investigation of the interactions between simulated climate warming and eutrophication and their impacts on biological structure and ecosystem processes...

  13. Length Scales of Reactive Transport in Basalt: Hydrothermal Flow-through Experiments and Anhydrite Precipitation

    Science.gov (United States)

    Los, C.; Kahl, W. A.; Bach, W.

    2017-12-01

    Hydrothermal circulation is a large contributor to mass and heat exchange between oceanic lithosphere and hydrosphere. Cold, unaltered seawater infiltrates in the shallow basaltic crust, leading to sulfate precipitation and clogging of fluid pathways. Anhydrite (CaSO4) veins are common in hydrothermal discharge zones, where entrained seawater is heated and anhydrite quickly forms. Anhydrite is also found in hydrothermal recharge zones, but questions regarding time and length scale in this setting remain. To investigate element transport and anhydrite precipitation we have conducted flow-through experiments using a gypsum-undersaturated CaSO4 solution in pre-fractured basalt at 95, 110 and 140°C. Each run was terminated upon clogging of the input tubes, which took 2-8 weeks. The rock core was scanned before the run and weekly during the experiment using X-ray tomography. Fluid major element chemistry was analyzed using ICP-OES. Geochemical modeling with the software package EQ3/6 showed that the starting solution became supersaturated in anhydrite (SI=IAP/K of 2.5 or higher) in all cases upon heating to the experimental temperature. The software CRUNCH FLOW was used to analyze chemical effects over the length of the core (3cm). The 95°C run and a first run at 110°C did not show any anhydrite. Instead, hematite rosettes and sulfur-bearing (maximum of 1 wt.%) globular Fe-rich structures were present. Tomography images showed that fractures and pores were slightly thinned over the whole core length. Single pores in a second 110°C run and fractures in the 140°C run did show formation of anhydrite and quartz close to the outlet. CRUNCH FLOW modeling predicts the observed release of Mg, Fe, Si, Al, Na and K due to silicate dissolution close to the inlet, while the outlet area should contain some anhydrite. No other sulfur-bearing phases were predicted. The results of this study show that anhydrite needs a large supersaturation (SI>2.5) to precipitate at temperatures

  14. Axioms for behavioural congruence of single-pass instruction sequences

    NARCIS (Netherlands)

    Bergstra, J.A.; Middelburg, C.A.

    2017-01-01

    In program algebra, an algebraic theory of single-pass instruction sequences, three congruences on instruction sequences are paid attention to: instruction sequence congruence, structural congruence, and behavioural congruence. Sound and complete axiom systems for the first two congruences were

  15. Groundwater flow through a natural fracture. Flow experiments and numerical modelling

    Energy Technology Data Exchange (ETDEWEB)

    Larsson, Erik [Chalmers Univ. of Technology, Goeteborg (Sweden). Dept of Geology

    1997-09-01

    Groundwater flow and transport play an important role not only for groundwater exploration but also in environmental engineering problems. This report considers how the hydraulic properties of fractures in crystalline rock depend on the fracture aperture geometry. Different numerical models are discussed and a FDM computer code for two- and three- dimensional flow-modelling has been developed. Different relations between the cells in the model are tested and compared with results in the literature. A laboratory experimental work has been done to carry out flow experiments and aperture measurements on the same specimen of a natural fracture. The drilled core sample had fractures parallel to the core axis and was placed inside a biaxial cell during the experiments. The water pressure gradient and the compression stress were varied during the experiments and also a tracer test was done. After the flow experiments, the aperture distribution for a certain compression was measured by injecting an epoxy resin into the fracture. The thickness of the resin layer was then studied in saw cut sections of the sample. The results from the experiments were used to validate numerical and analytical models, based on aperture distribution, for flow and transport simulations. In the disturbed zone around a drift both water and air are present in the fractures. The gas will go to the most wide part of the fracture because the capillarity and the conductivity decrease. The dependence of the effective conductivity on the variance of the conductivity and the effect of extinction of highly conductive cells has also been studied. A discussion of how gas in fractures around a drift can cause a skin effect is modelled and an example is given of what a saturation depending on the magnitude of the flow causes. 25 refs, 17 tabs, 43 figs.

  16. Long-term flow-through column experiments and their relevance to natural granitoid weathering rates

    Science.gov (United States)

    White, Art F.; Schulz, Marjorie S.; Lawrence, Corey R.; Vivit, Davison V.; Stonestrom, David A.

    2017-04-01

    Four pairs of fresh and partly-weathered granitoids, obtained from well-characterized watersheds-Merced River, CA, USA; Panola, GA, USA; Loch Vale, CO, USA, and Rio Icacos, Puerto Rico-were reacted in columns under ambient laboratory conditions for 13.8 yrs, the longest running experimental weathering study to date. Low total column mass losses (column experiments. Fresh granitoid effluent solute concentrations initially declined rapidly, followed by much slower decreases over the next decade. Weathered granitoid effluent concentrations increased modestly over the same time period, indicating losses of natural Fe-oxide and/or clay coatings and the increased exposure of primary mineral surfaces. Corresponding (fresh and weathered) elemental effluent concentrations trended toward convergence during the last decade of reaction. NETPATH/PHREEQC code simulations indicated non-stoichiometric dissolution involving Ca release from disseminated calcite and excess K release from interlayer biotite. Effluent 87Sr/85Sr ratios reflected a progressive weathering sequence beginning and ending with 87Sr/85Sr values of plagioclase with an additional calcite input and a radiogenic biotite excursion proportional to the granitoid ages. Effluents became thermodynamically saturated with goethite and gibbsite, slightly under-saturated with kaolinite and strongly under-saturated with plagioclase, consistent with kinetically-limited weathering in which solutes such as Na varied with column flow rates. Effluent Na concentrations showed no clear trend with time during the last decade of reaction (fresh granitoids) or increased slowly with time (weathered granitoids). Analysis of cumulative Na release indicated that plagioclase dissolution achieved steady state in 3 of the 4 fresh granitoids during the last decade of reaction. Surface-area normalized plagioclase dissolution rates exhibited a narrow range (0.95-1.26 10-13 moles m-2 s-1), in spite of significant stoichiometric differences (An0

  17. Determination of dissolution rates of spent fuel in carbonate solutions under different redox conditions with a flow-through experiment

    International Nuclear Information System (INIS)

    Roellin, S.; Spahiu, K.; Eklund, U.-B.

    2001-01-01

    Dissolution rates of spent UO 2 fuel have been investigated using flow-through experiments under oxidizing, anoxic and reducing conditions. For oxidizing conditions, approximately congruent dissolution rates were obtained in the pH range 3-9.3 for U, Np, Ba, Tc, Cs, Sr and Rb. For these elements, steady-state conditions were obtained in the flow rate range 0.02-0.3 ml min -1 . The dissolution rates were about 3 mg d -1 m -2 for pH>6. For pH 2 (g) saturated solutions dropped by up to four orders of magnitude as compared to oxidizing conditions. Because of the very low concentrations, only U, Pu, Am, Mo, Tc and Cs could be measured. For anoxic conditions, both the redox potential and dissolution rates increased approaching the same values as under oxidizing conditions

  18. Fringe-controlled biodegradation under dynamic conditions: Quasi 2-D flow-through experiments and reactive-transport modeling

    Science.gov (United States)

    Eckert, Dominik; Kürzinger, Petra; Bauer, Robert; Griebler, Christian; Cirpka, Olaf A.

    2015-01-01

    Biodegradation in contaminated aquifers has been shown to be most pronounced at the fringe of contaminant plumes, where mixing of contaminated water and ambient groundwater, containing dissolved electron acceptors, stimulates microbial activity. While physical mixing of contaminant and electron acceptor by transverse dispersion has been shown to be the major bottleneck for biodegradation in steady-state plumes, so far little is known on the effect of flow and transport dynamics (caused, e.g., by a seasonally fluctuating groundwater table) on biodegradation in these systems. Towards this end we performed experiments in quasi-two-dimensional flow-through microcosms on aerobic toluene degradation by Pseudomonas putida F1. Plume dynamics were simulated by vertical alteration of the toluene plume position and experimental results were analyzed by reactive-transport modeling. We found that, even after disappearance of the toluene plume for two weeks, the majority of microorganisms stayed attached to the sediment and regained their full biodegradation potential within two days after reappearance of the toluene plume. Our results underline that besides microbial growth, also maintenance and dormancy are important processes that affect biodegradation performance under transient environmental conditions and therefore deserve increased consideration in future reactive-transport modeling.

  19. Single-Pass Clustering Algorithm Based on Storm

    Science.gov (United States)

    Fang, LI; Longlong, DAI; Zhiying, JIANG; Shunzi, LI

    2017-02-01

    The dramatically increasing volume of data makes the computational complexity of traditional clustering algorithm rise rapidly accordingly, which leads to the longer time. So as to improve the efficiency of the stream data clustering, a distributed real-time clustering algorithm (S-Single-Pass) based on the classic Single-Pass [1] algorithm and Storm [2] computation framework was designed in this paper. By employing this kind of method in the Topic Detection and Tracking (TDT) [3], the real-time performance of topic detection arises effectively. The proposed method splits the clustering process into two parts: one part is to form clusters for the multi-thread parallel clustering, the other part is to merge the generated clusters in the previous process and update the global clusters. Through the experimental results, the conclusion can be drawn that the proposed method have the nearly same clustering accuracy as the traditional Single-Pass algorithm and the clustering accuracy remains steady, computing rate increases linearly when increasing the number of cluster machines and nodes (processing threads).

  20. Flow-through Column Experiments and Modeling of Microbially Mediated Cr(VI) Reduction at Hanford 100H

    Science.gov (United States)

    Yang, L.; Molins, S.; Beller, H. R.; Brodie, E. L.; Steefel, C.; Nico, P. S.; Han, R.

    2010-12-01

    Microbially mediated Cr(VI) reduction at the Hanford 100H area was investigated by flow-through column experiments. Three separate experiments were conducted to promote microbial activities associated with denitrification, iron and sulfate reduction, respectively. Replicate columns packed with natural sediments from the site under anaerobic environment were injected with 5mM Lactate as the electron donor and 5 μM Cr(VI) in all experiments. Sulfate and nitrate solutions were added to act as the main electron acceptors in the respective experiments, while iron columns relied on the indigenous sediment iron (and manganese) oxides as electron acceptors. Column effluent solutions were analyzed by IC and ICP-MS to monitor the microbial consumption/conversion of lactate and the associated Cr(VI) reduction. Biogeochemical reactive transport modeling was performed to gain further insights into the reaction mechanisms and Cr(VI) bioreduction rates. All experimental columns showed a reduction of the injected Cr(VI). Columns under denitrifying conditions showed the least Cr(VI) reduction at early stages (growth completely depleted influent ammonium, and called for an additional source of N to account for the measured reduction rates. Iron columns were the least active with undetectable consumption of the injected lactate, slowest cell growth, and the smallest change in Cr(VI) concentrations during the course of the experiment. In contrast, columns under sulfate-reducing/fermentative conditions exhibited the greatest Cr(VI) reduction capacity. Two sulfate columns evolved to complete lactate fermentation with acetate and propionate produced in the column effluent after 40 days of experiments. These fermenting columns showed a complete removal of injected Cr(VI), visible precipitation of sulfide minerals, and a significant increase in effluent Fe and Mn concentrations. Reactive transport simulations suggested that direct reduction of Cr(VI) by Fe(II) and Mn(II) released from the

  1. Characterization of gas flow through low-permeability clay-stone: laboratory experiments and two-phase flow analyses

    International Nuclear Information System (INIS)

    Senger, R.K.; Romero, E.; Ferrari, A.; Marschall, P.L.

    2012-01-01

    Document available in extended abstract form only. The characterization of gas migration through a low-permeability clay host rock for repositories is important because significant amounts of waste-generated gas are expected to migrate from low- and intermediate-level waste (L/ILW) and high-level waste (HLW) repositories into the surrounding host rock. In order to assess the long-term safety of the repository, a comprehensive understanding of the relevant transport phenomena of gas flow through low-permeability clay is required. The assessment of gas migration from the repository is done through large-scale numerical models which incorporate the two-phase flow and associated constitutive models needed to properly represent the relevant processes. The National Cooperative for the Disposal of Radioactive Waste (NAGRA), Switzerland has proposed the Opalinus Clay (OPA) as one of the host rocks for the Stage 1 of the Sectoral Plan process. For this, Nagra has developed a comprehensive program to characterize gas flow through the Opalinus Clay through laboratory tests to determine the relevant hydraulic, geomechanical, and two-phase properties and detailed analyses for developing appropriate constitutive models. Laboratory tests on OPA cores from the borehole BHG-D1 borehole in Mont Terri were performed by two different laboratories. Whereas EPFL focused on retention behaviour and geomechanical tests, UPC performed specific water and air injection tests to determine single-phase liquid and two-phase properties. Oedometer tests were performed by both laboratories to study rock compressibility at different stress levels and water permeability dependency on void ratio. The retention data measured by EPFL and UPC were comparable and could be fitted with a van Genuchten model using the same parameters. The focus of this paper is on the air-injection test, which was performed on two core samples with flow parallel and perpendicular to bedding. Figure 2 shows the time evolution

  2. The Single Pass RF Driver: Final beam compression

    International Nuclear Information System (INIS)

    Burke, Robert

    2014-01-01

    The Single Pass RF Driver (SPRFD) compacts the beam from the linac without storage rings by manipulations that take advantage of the multiplicity of isotopes (16), the preserved µbunch structure, and increased total linac current. Magnetic switches on a first set of delay lines rearrange the internal structure of the various isotopic beams. A second set of delay lines sets the relative timing of the 16 isotopic beam sections so they will telescope at the pellet, in one of multiple fusion chambers, e.g. 10. Shortening each isotopic beam section uses preservation of the µbunch structure up to the final ∼2 km drift before final focus. Just before the final drift, differential acceleration of the µbunches in each isotopic beam section (128 total) launches an axial collapse, referred to as the “Slick”. The µbunches interpenetrate as their centers of mass move toward each other and individual µbunches lengthen due to their momentum spread. In longitudinal phase space they slide over one another as they lengthen in time and slim down in instantaneous energy spread. The permissible amount of µbunch lengthening is set by the design pulse shape at the pellet, which varies for different groups of isotopes. In narrow bands of ranges according to the role for each isotope group in the pellet, the ranges extend from 1 to 10 g/cm 2 to drive the cylinder barrel and thin hemispherical end caps, to heat the ∼0.5 g/cm 2 ρR fast ignition zone, and to improve the quasi-sphericity of the compression of the fast ignition zones at the pellet's ends. Because the µbunch–µbunch momentum differences are correlated, time-ramped beamline transport elements close after the differential accelerator are used to correct the associated shifts of focal point. Beam neutralization is needed after the differential acceleration until adjacent bunches begin to overlap. Concurrent collapse of each isotope and telescoping of the 16 isotopes cause the current in each beamline to rise

  3. Modeling changes in mineral assemblages and sorptive capacity within the altered zone: analytical data for flow-through experiment

    Energy Technology Data Exchange (ETDEWEB)

    DeLoach, L., LLNL

    1997-10-01

    Mineral changes that may occur within the altered zone (AZ) will develop in response to complex interactions among condensate, pore waters, fracture mineralogy, and the mineralogy of the in situ rocks. At the Yucca Mountain site, the mineralogy of the in situ rock varies from one lithologic unit to another, reflecting different initial bulk rock chemistries and different degrees of devitrification and welding. To account for these variations when describing the possible changes the potential repository block will experience during heating and fluid movement, a credible database of experimental results describing the chemical and mineralogical consequences of rock-water interaction must be available; against this, modeling capabilities are compared. Once the capability is established to accurately simulate the time-dependent evolution of rock-water systems at elevated temperatures, confidence can be placed in models of the mineral changes expected within the AZ. This report describes experiments and modeling that consider the effects of different starting materials on mineral evolution and on the rates of mineral formation. Bounds are placed on the kinetics of the controlling dissolution-rate constants, which are the fundamental parameters that influence secondary mineral development. The sensitivity of the results to different secondary minerals is considered in the simulations. The most significant parameters affecting the results are shown to be the effective surface areas of the phases involved, the rate constants for the phases, and, for the case of vitric material, the model used for glass dissolution.

  4. Feeding strategies for groundwater enhanced biodenitrification in an alluvial aquifer: Chemical, microbial and isotope assessment of a 1D flow-through experiment

    Energy Technology Data Exchange (ETDEWEB)

    Vidal-Gavilan, G., E-mail: georginavidal@biorem.cat [D D' ENGINY BIOREM S.L., Madrazo 68, bxs., 08006 Barcelona (Spain); Grup de Mineralogia Aplicada i Medi Ambient, Departament de Cristallografia, Mineralogia i Dipòsits MInerals, Universitat de Barcelona, Martí i Franquès s/n, 08028 Barcelona (Spain); Carrey, R., E-mail: rcarrey@ub.edu [Grup de Mineralogia Aplicada i Medi Ambient, Departament de Cristallografia, Mineralogia i Dipòsits MInerals, Universitat de Barcelona, Martí i Franquès s/n, 08028 Barcelona (Spain); Solanas, A., E-mail: asolanas@ub.edu [Departament de Microbiologia, Facultat de Biologia, Universitat de Barcelona, Avgda. Diagonal 645, 08028 Barcelona (Spain); Soler, A., E-mail: albertsolergil@ub.edu [Grup de Mineralogia Aplicada i Medi Ambient, Departament de Cristallografia, Mineralogia i Dipòsits MInerals, Universitat de Barcelona, Martí i Franquès s/n, 08028 Barcelona (Spain)

    2014-10-01

    Nitrate-removal through enhanced in situ biodenitrification (EISB) is an existing alternative for the recovery of groundwater quality, and is often suggested for use in exploitation wells pumping at small flow-rates. Innovative approaches focus on wider-scale applications, coupling EISB with water-management practices and new monitoring tools. However, before this approach can be used, some water-quality issues such as the accumulation of denitrification intermediates and/or of reduced compounds from other anaerobic processes must be addressed. With such a goal, a flow-through experiment using 100 mg-nitrate/L groundwater was built to simulate an EISB for an alluvial aquifer. Heterotrophic denitrification was induced through the periodic addition of a C source (ethanol), with four different C addition strategies being evaluated to improve the quality of the denitrified water. Chemical, microbial and isotope analyses of the water were performed. Biodenitrification was successfully stimulated by the daily addition of ethanol, easily achieving drinking water standards for both nitrate and nitrite, and showing an expected linear trend for nitrogen and oxygen isotope fractionation, with a εN/εO value of 1.1. Nitrate reduction to ammonium was never detected. Water quality in terms of remaining C, microbial counts, and denitrification intermediates was found to vary with the experimental time, and some secondary microbial respiration processes, mainly manganese reduction, were suspected to occur. Carbon isotope composition from the remaining ethanol also changed, from an initial enrichment in {sup 13}C-ethanol compared to the value of the injected ethanol (− 30.6‰), to a later depletion, achieving δ{sup 13}C values well below the initial isotope composition (to a minimum of − 46.7‰). This depletion in the heavy C isotope follows the trend of an inverse fractionation. Overall, our results indicated that most undesired effects on water quality may be controlled

  5. Model for Estimation of Thermal History Produced by a Single Pass Underwater Wet Weld

    National Research Council Canada - National Science Library

    Dill, Jay

    1997-01-01

    Thermal history calculations for single pass underwater wet weldments were made by solving the appropriate beat transfer equations using the three-dimensional Crank-Nicholson finite difference method...

  6. Parametric analysis of plastic strain and force distribution in single pass metal spinning

    Energy Technology Data Exchange (ETDEWEB)

    Choudhary, Shashank, E-mail: shashankbit08@gmail.com, E-mail: mohantejesh93@gmail.com, E-mail: regalla@hyderabad.bits-pilani.ac.in, E-mail: ksuresh@hyderabad.bits-pilani.ac.in; Tejesh, Chiruvolu Mohan, E-mail: shashankbit08@gmail.com, E-mail: mohantejesh93@gmail.com, E-mail: regalla@hyderabad.bits-pilani.ac.in, E-mail: ksuresh@hyderabad.bits-pilani.ac.in; Regalla, Srinivasa Prakash, E-mail: shashankbit08@gmail.com, E-mail: mohantejesh93@gmail.com, E-mail: regalla@hyderabad.bits-pilani.ac.in, E-mail: ksuresh@hyderabad.bits-pilani.ac.in; Suresh, Kurra, E-mail: shashankbit08@gmail.com, E-mail: mohantejesh93@gmail.com, E-mail: regalla@hyderabad.bits-pilani.ac.in, E-mail: ksuresh@hyderabad.bits-pilani.ac.in [Department of Mechanical Engineering, BITS-Pilani, Hyderabad Campus, Shamirpet, Hyderabad, 500078, Andhra Pradesh (India)

    2013-12-16

    Metal spinning also known as spin forming is one of the sheet metal working processes by which an axis-symmetric part can be formed from a flat sheet metal blank. Parts are produced by pressing a blunt edged tool or roller on to the blank which in turn is mounted on a rotating mandrel. This paper discusses about the setting up a 3-D finite element simulation of single pass metal spinning in LS-Dyna. Four parameters were considered namely blank thickness, roller nose radius, feed ratio and mandrel speed and the variation in forces and plastic strain were analysed using the full-factorial design of experiments (DOE) method of simulation experiments. For some of these DOE runs, physical experiments on extra deep drawing (EDD) sheet metal were carried out using En31 tool on a lathe machine. Simulation results are able to predict the zone of unsafe thinning in the sheet and high forming forces that are hint to the necessity for less-expensive and semi-automated machine tools to help the household and small scale spinning workers widely prevalent in India.

  7. Modacrylic anion-exchange fibers for Cr(VI) removal from chromium-plating rinse water in batch and flow-through column experiments.

    Science.gov (United States)

    Lee, Seung-Chan; Kang, Jin-Kyu; Sim, Eun-Hye; Choi, Nag-Choul; Kim, Song-Bae

    2017-11-10

    The aim of this study was to investigate Cr(VI) removal from chromium-plating rinse water using modacrylic anion-exchange fibers (KaracaronTM KC31). Batch experiments were performed with synthetic Cr(VI) solutions to characterize the KC31 fibers in Cr(VI) removal. Cr(VI) removal by the fibers was affected by solution pH; the Cr(VI) removal capacity was the highest at pH 2 and decreased gradually with a pH increase from 2 to 12. In regeneration and reuse experiments, the Cr(VI) removal capacity remained above 37.0 mg g -1 over five adsorption-desorption cycles, demonstrating that the fibers could be successfully regenerated with NaCl solution and reused. The maximum Cr(VI) removal capacity was determined to be 250.3 mg g -1 from the Langmuir model. In Fourier-transform infrared spectra, a Cr = O peak newly appeared at 897 cm -1 after Cr(VI) removal, whereas a Cr-O peak was detected at 772 cm -1 due to the association of Cr(VI) ions with ion-exchange sites. X-ray photoelectron spectroscopy analyses demonstrated that Cr(VI) was partially reduced to Cr(III) after the ion exchange on the surfaces of the fibers. Batch experiments with chromium-plating rinse water (Cr(VI) concentration = 1178.8 mg L -1 ) showed that the fibers had a Cr(VI) removal capacity of 28.1-186.4 mg g -1 under the given conditions (fiber dose = 1-10 g L -1 ). Column experiments (column length = 10 cm, inner diameter = 2.5 cm) were conducted to examine Cr(VI) removal from chromium-plating rinse water by the fibers under flow-through column conditions. The Cr(VI) removal capacities for the fibers at flow rates of 0.5 and 1.0 mL min -1 were 214.8 and 171.5 mg g -1 , respectively. This study demonstrates that KC31 fibers are effective in the removal of Cr(VI) ions from chromium-plating rinse water.

  8. Highly efficient single-pass sum frequency generation by cascaded nonlinear crystals

    DEFF Research Database (Denmark)

    Hansen, Anders Kragh; Andersen, Peter E.; Jensen, Ole Bjarlin

    2015-01-01

    The cascading of nonlinear crystals has been established as a simple method to greatly increase the conversion efficiency of single-pass second-harmonic generation compared to a single-crystal scheme. Here, we show for the first time that the technique can be extended to sum frequency generation......, despite differences in the phase relations of the involved fields. An unprecedented 5.5 W of continuous-wave diffraction-limited green light is generated from the single-pass sum frequency mixing of two diode lasers in two periodically poled nonlinear crystals (conversion efficiency 50%). The technique...

  9. Fuel-element failures in Hanford single-pass reactors 1944--1971

    Energy Technology Data Exchange (ETDEWEB)

    Gydesen, S.P.

    1993-07-01

    The primary objective of the Hanford Environmental Dose Reconstruction (HEDR) Project is to estimate the radiation dose that individuals could have received as a result of emissions since 1944 from the US Department of Energy`s (DOE) Hanford Site near Richland, Washington. To estimate the doses, the staff of the Source Terms Task use operating information from historical documents to approximate the radioactive emissions. One source of radioactive emissions to the Columbia River came from leaks in the aluminum cladding of the uranium metal fuel elements in single-pass reactors. The purpose of this letter report is to provide photocopies of the documents that recorded these failures. The data from these documents will be used by the Source Terms Task to determine the contribution of single-pass reactor fuel-element failures to the radioactivity of the reactor effluent from 1944 through 1971. Each referenced fuel-element failure occurring in the Hanford single-pass reactors is addressed. The first recorded failure was in 1948, the last in 1970. No records of fuel-element failures were found in documents prior to 1948. Data on the approximately 2000 failures which occurred during the 28 years (1944--1971) of Hanford single-pass reactor operations are provided in this report.

  10. Fuel-element failures in Hanford single-pass reactors 1944--1971

    International Nuclear Information System (INIS)

    Gydesen, S.P.

    1993-07-01

    The primary objective of the Hanford Environmental Dose Reconstruction (HEDR) Project is to estimate the radiation dose that individuals could have received as a result of emissions since 1944 from the US Department of Energy's (DOE) Hanford Site near Richland, Washington. To estimate the doses, the staff of the Source Terms Task use operating information from historical documents to approximate the radioactive emissions. One source of radioactive emissions to the Columbia River came from leaks in the aluminum cladding of the uranium metal fuel elements in single-pass reactors. The purpose of this letter report is to provide photocopies of the documents that recorded these failures. The data from these documents will be used by the Source Terms Task to determine the contribution of single-pass reactor fuel-element failures to the radioactivity of the reactor effluent from 1944 through 1971. Each referenced fuel-element failure occurring in the Hanford single-pass reactors is addressed. The first recorded failure was in 1948, the last in 1970. No records of fuel-element failures were found in documents prior to 1948. Data on the approximately 2000 failures which occurred during the 28 years (1944--1971) of Hanford single-pass reactor operations are provided in this report

  11. High-aspect-ratio grooves fabricated in silicon by a single pass of femtosecond laser pulses

    International Nuclear Information System (INIS)

    Ma Yuncan; Shi Haitao; Si Jinhai; Ren Hai; Chen Tao; Chen Feng; Hou Xun

    2012-01-01

    High-aspect-ratio grooves have been fabricated in silicon by a single pass of femtosecond laser pulses in water and ambient air. Scanning electron microscopy and energy dispersive x-ray spectroscopy were employed to image for the morphology of the photoinduced grooves and analyze the chemical composition in the surrounding of the grooves. It was observed that the sidewall of the grooves fabricated in water was much smoother than that in ambient air, and there were homogeneous nano-scale protrusions on the sidewall of the grooves fabricated in water. Meanwhile, oxygen species, which was incorporated into the grooves fabricated in air, was not observed in those in water.

  12. Is DOM driver of the microbial carrying capacity in pristine porous groundwater ecosystems? - lab-scale experiments in 2D sediment flow-through microcosms

    Science.gov (United States)

    Hofmann, Roland; Griebler, Christian

    2017-04-01

    Groundwater ecosystems are an essential resource for drinking water and at the same time constitute fascinating habitats subject to increasing (anthropogenic) disturbances. In our research, we look for ways to qualitatively and quantitatively access, and predict the resistance and resilience (potential) of groundwater ecosystems in consequence of selected disturbances. As a central goal we hope to identify and quantify the underlying biological and ecological key drivers of the microbial Carrying Capacity (mCC) - an ecological concept established in macro-ecology - we assume directly connected to the ecosystem's productivity and the resistance and resilience of aquifers. We further hypothesize, that the ecosystems' mCC is a result of available energy and constitutes a promising proxy for the potential of groundwater ecosystems to withstand impacts and recover from it. In a first approach we studied the dynamics of the microbial standing stock (biomass) and growth (productivity) productivity of a natural groundwater microbial community in parallel 2-D sediment flow-through systems. Selected zones of the model aquifers were disturbed by elevated DOM concentrations. Both the 'mobile' (free floating) and 'sessile' (sediment attached) microbial components were followed over time in terms of biomass, growth, and specific activities (ATP, carbon use efficiency) and taxonomic composition. Sediment regions supplied with elevated concentrations of natural DOM showed increased biomass, activities and taxonomic richness with the sediment community, while differences in the mobile microbial were marginal. Specifically, the carbon use efficiency was significantly increased in the DOM amended sediment zones. In contrast, the microbial community that received the mainly refractory natural background DOM was able to metabolize polymers more efficiently in substrate use tests (ECOLOG), seen as an adaptation to the energy-poor subsurface. Quasi-stationary conditions were reached in

  13. Generic, network schema agnostic sparse tensor factorization for single-pass clustering of heterogeneous information networks.

    Directory of Open Access Journals (Sweden)

    Jibing Wu

    Full Text Available Heterogeneous information networks (e.g. bibliographic networks and social media networks that consist of multiple interconnected objects are ubiquitous. Clustering analysis is an effective method to understand the semantic information and interpretable structure of the heterogeneous information networks, and it has attracted the attention of many researchers in recent years. However, most studies assume that heterogeneous information networks usually follow some simple schemas, such as bi-typed networks or star network schema, and they can only cluster one type of object in the network each time. In this paper, a novel clustering framework is proposed based on sparse tensor factorization for heterogeneous information networks, which can cluster multiple types of objects simultaneously in a single pass without any network schema information. The types of objects and the relations between them in the heterogeneous information networks are modeled as a sparse tensor. The clustering issue is modeled as an optimization problem, which is similar to the well-known Tucker decomposition. Then, an Alternating Least Squares (ALS algorithm and a feasible initialization method are proposed to solve the optimization problem. Based on the tensor factorization, we simultaneously partition different types of objects into different clusters. The experimental results on both synthetic and real-world datasets have demonstrated that our proposed clustering framework, STFClus, can model heterogeneous information networks efficiently and can outperform state-of-the-art clustering algorithms as a generally applicable single-pass clustering method for heterogeneous network which is network schema agnostic.

  14. Experimental and simulation studies on a single pass, double duct solar air heater

    Energy Technology Data Exchange (ETDEWEB)

    Forson, F.K. [Kwame Nkrumah Univ. of Science and Technology, Dept. of Mechanical Engineering, Kumasi (Ghana); Rajakaruna, H. [De Montfort Univ., School of Engineering and Technology, Leicester (United Kingdom)

    2003-05-01

    A mathematical model of a single pass, double duct solar air heater (SPDDSAH) is described. The model provides a design tool capable of predicting: incident solar radiation, heat transfer coefficients, mean air flow rates, mean air temperature and relative humidity at the exit. Results from the simulation are presented and compared with experimental ones obtained on a full scale air heater and a small scale laboratory one. Reasonable agreement between the predicted and measured values is demonstrated. Predicted results from a parametric study are also presented. It is shown that significant improvement in the SPDDSAH performance can be obtained with an appropriate choice of the collector parameters and the top to bottom channel depth ratio of the two ducts. The air mass flow rate is shown to be the dominant factor in determining the overall efficiency of the heater. (Author)

  15. High-Accuracy Elevation Data at Large Scales from Airborne Single-Pass SAR Interferometry

    Directory of Open Access Journals (Sweden)

    Guy Jean-Pierre Schumann

    2016-01-01

    Full Text Available Digital elevation models (DEMs are essential data sets for disaster risk management and humanitarian relief services as well as many environmental process models. At present, on the hand, globally available DEMs only meet the basic requirements and for many services and modeling studies are not of high enough spatial resolution and lack accuracy in the vertical. On the other hand, LiDAR-DEMs are of very high spatial resolution and great vertical accuracy but acquisition operations can be very costly for spatial scales larger than a couple of hundred square km and also have severe limitations in wetland areas and under cloudy and rainy conditions. The ideal situation would thus be to have a DEM technology that allows larger spatial coverage than LiDAR but without compromising resolution and vertical accuracy and still performing under some adverse weather conditions and at a reasonable cost. In this paper, we present a novel single pass In-SAR technology for airborne vehicles that is cost-effective and can generate DEMs with a vertical error of around 0.3 m for an average spatial resolution of 3 m. To demonstrate this capability, we compare a sample single-pass In-SAR Ka-band DEM of the California Central Valley from the NASA/JPL airborne GLISTIN-A to a high-resolution LiDAR DEM. We also perform a simple sensitivity analysis to floodplain inundation. Based on the findings of our analysis, we argue that this type of technology can and should be used to replace large regions of globally available lower resolution DEMs, particularly in coastal, delta and floodplain areas where a high number of assets, habitats and lives are at risk from natural disasters. We conclude with a discussion on requirements, advantages and caveats in terms of instrument and data processing.

  16. Evaluation of a single-pass continuous whole-body 16-MDCT protocol for patients with polytrauma.

    Science.gov (United States)

    Nguyen, Duy; Platon, Alexandra; Shanmuganathan, Kathirkamanathan; Mirvis, Stuart E; Becker, Christoph D; Poletti, Pierre-Alexandre

    2009-01-01

    The purpose of this study was to compare a conventional multiregional MDCT protocol with two continuous single-pass whole-body MDCT protocols in imaging of patients with polytrauma. Ninety patients with polytrauma underwent whole-body 16-MDCT with a conventional (n=30) or one of two single-pass (n=60) protocols. The conventional protocol included unenhanced scans of the head and cervical spine and contrast-enhanced helical scans (140 mL, 4 mL/s, 300 mg I/mL) of the thorax and abdomen. The single-pass protocols consisted of unenhanced scans of the head followed by one-sweep acquisition from the circle of Willis through the pubic symphysis with a biphasic (150 mL, 6 and 4 mL/s, 300 mg I/mL) or monophasic (110 mL, 4 mL/s, 400 mg I/mL) injection. Acquisition times and interval delays between head, chest, and abdominal scans were recorded. Contrast enhancement was measured in the aortic arch, liver, spleen, and kidney. Diagnostic image quality in the same areas was assessed on a 4-point scale. Median acquisition times for the single-pass protocols were significantly shorter (-42.5%) than the acquisition time for the conventional protocol. No significant differences were found in mean enhancement values in the aorta, liver, spleen, and kidney for the three protocols. The image quality with both single-pass protocols was better than that with the conventional protocol in assessment of the mediastinum and cervical spine (p<0.05). There was no significant difference between the single-pass protocols. Use of single-pass continuous whole-body MDCT protocols can significantly decrease examination time for patients with polytrauma and improve image quality compared with a conventional serial scan protocol. Monophasic injection with highly concentrated contrast medium can reduce injection flow rate and should therefore be preferred to a biphasic injection technique.

  17. [Intestinal absorption of different combinations of active compounds from Gegenqinlian decoction by rat single pass intestinal perfusion in situ].

    Science.gov (United States)

    An, Rui; Zhang, Hua; Zhang, Yi-Zhu; Xu, Ran-Chi; Wang, Xin-Hong

    2012-12-01

    The aim is to study the intestinal absorption of different combinations of active compounds out of Gegenqinlian decoction. Rat single pass intestinal perfusion model with jugular vein cannulated was used. Samples were obtained continuously from the outlet perfusate and the mesenteric vein. The levels of puerarin, daidzin, liquilitin, baicalin, wogonoside, jatrorrhizine, berberine and palmatine were determined by LC-MS/MS and their permeability coefficients were calculated. The results showed that Glycyrrhiza could promote the absorption of the active ingredients in Pueraria which is the monarch herb; meanwhile, Pueraria also played a role in promoting the absorption of liquilitin. Based on the Gegenqinlian decoction and the different combinations experiments, the results concerning the absorption of baicalin and wogonoside were as follows. For baicalin, Pueraria and Glycyrrhiza could promote its absorption and the effect of Pueraria was more obvious. For wogonoside, Pueraria could also promote its absorption, while Glycyrrhiza played a opposite role. Pueraria and Glycyrrhiza both played a part in promoting the absorption of jateorhizine, berberine and palmatine, the effective compounds in Coptis.

  18. Safety and efficacy of high fluence CO2 laser skin resurfacing with a single pass.

    Science.gov (United States)

    Khosh, M M; Larrabee, W F; Smoller, B

    1999-01-01

    Carbon dioxide (CO2) laser skin resurfacing has nearly replaced more traditional methods of superficial skin rejuvenation. Post-treatment erythema is the most common side effect of this method of skin resurfacing. Sublethal thermal damage to the dermis has been proposed as an etiology for post laser erythema. Recent developments in laser resurfacing technology have aimed at minimizing thermal damage to the dermis. To determine depth of skin ablation, extent of thermal injury, and ideal laser parameters for the FeatherTouch laser system. To assess the safety and efficacy of laser resurfacing at high energy fluences with a single pass. Laser resurfacing was performed in the preauricular skin of five patients undergoing rhytidectomy. A total of 60 sites were tested with fluences of 7 to 17 Joules/cm2. Histologic evaluation of excised skin showed maximal thermal injury to be restricted to 60 microns in the papillary dermis. The reticular dermis showed no evidence of injury. Based on these findings, laser resurfacing at 17 J/cm2 (70 watts) was performed on 30 patients (in the periorbital area, a maximum of 9 J/cm2 or 36 watts was used). Follow up ranged between 12 and 18 months. Based on histologic comparison of average and high fluence laser resurfacing, high fluence laser resurfacing did not cause added thermal damage to the reticular dermis. In the clinical group, no major complications such as scarring, scleral show, infection or ectropion were encountered. Transient hyperpigmentation was noted in three patients. Overall patient satisfaction was good to excellent. Post-treatment erythema lasted an average of 4 weeks. We conclude that CO2 laser resurfacing of the face (excluding the periorbital region) can be performed safely and effectively, with the FeatherTouch laser, at 17 J/cm2 with one pass. In our group of patients, laser resurfacing with a single pass at 17 J/cm2 caused less post-operative erythema than two or more passes at 9 J/cm2.

  19. Capacitive deionization of arsenic-contaminated groundwater in a single-pass mode.

    Science.gov (United States)

    Fan, Chen-Shiuan; Liou, Sofia Ya Hsuan; Hou, Chia-Hung

    2017-10-01

    A single-pass-mode capacitive deionization (CDI) reactor was used to remove arsenic from groundwater in the presence of multiple ions. The CDI reactor involved an applied voltage of 1.2 V and six cell pairs of activated carbon electrodes, each of which was 20 × 30 cm 2 . The results indicate that this method achieved an effluent arsenic concentration of 0.03 mg L -1 , which is lower than the arsenic concentration standard for drinking water and irrigation sources in Taiwan, during the charging stage. Additionally, the ability of the CDI to remove other coexisting ions was studied. The presence of other ions has a significant influence on the removal of arsenic from groundwater. From the analysis of the electrosorption selectivity, the preference for anion removal could be ordered as follows: NO 3 -  > SO 4 2-  > F -  > Cl - >As. The electrosorption selectivity for cations could be ordered as follows: Ca 2+  > Mg 2+  > Na +  ∼ K + . Moreover, monovalent cations can be replaced by divalent cations at the electrode surface in the later period of the electrosorption stage. Consequently, activated carbon-based capacitive deionization is demonstrated to be a high-potential technology for remediation of arsenic-contaminated groundwater. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Error Analysis for High Resolution Topography with Bi-Static Single-Pass SAR Interferometry

    Science.gov (United States)

    Muellerschoen, Ronald J.; Chen, Curtis W.; Hensley, Scott; Rodriguez, Ernesto

    2006-01-01

    We present a flow down error analysis from the radar system to topographic height errors for bi-static single pass SAR interferometry for a satellite tandem pair. Because of orbital dynamics the baseline length and baseline orientation evolve spatially and temporally, the height accuracy of the system is modeled as a function of the spacecraft position and ground location. Vector sensitivity equations of height and the planar error components due to metrology, media effects, and radar system errors are derived and evaluated globally for a baseline mission. Included in the model are terrain effects that contribute to layover and shadow and slope effects on height errors. The analysis also accounts for nonoverlapping spectra and the non-overlapping bandwidth due to differences between the two platforms' viewing geometries. The model is applied to a 514 km altitude 97.4 degree inclination tandem satellite mission with a 300 m baseline separation and X-band SAR. Results from our model indicate that global DTED level 3 can be achieved.

  1. Low energy dark current collimation system in single-pass linacs

    Science.gov (United States)

    Bettoni, S.; Craievich, P.; Pedrozzi, M.; Schaer, M.; Stingelin, L.

    2018-02-01

    The dark current emitted from a surface of a radio frequency cavity may be a severe issue for the activation and the protection of the components of linear accelerators, if this current is lost in an uncontrolled manner. For a single-pass linac based on a photo-injector, we studied the possibility of using a collimator installed at low energy (below 10 MeV) to dump the maximum fraction of the dark current before it is transported along the linac. We developed and experimentally verified an emission and tracking model that we used to study and optimize the dark current mitigation at SwissFEL test facility. We optimized a collimator, which is expected to reduce by two orders of magnitude the transport of the dark current to the first compressor. We have also verified the effects of wakefield excited by the beam itself passing through the collimator at such a low energy, comparing the results of beam-based measurements with an analytical model.

  2. Non-destructive single-pass low-noise detection of ions in a beamline

    Science.gov (United States)

    Schmidt, Stefan; Murböck, Tobias; Andelkovic, Zoran; Birkl, Gerhard; Nörtershäuser, Wilfried; Stahl, Stefan; Vogel, Manuel

    2015-11-01

    We have conceived, built, and operated a device for the non-destructive single-pass detection of charged particles in a beamline. The detector is based on the non-resonant pick-up and subsequent low-noise amplification of the image charges induced in a cylindrical electrode surrounding the particles' beam path. The first stage of the amplification electronics is designed to be operated from room temperature down to liquid helium temperature. The device represents a non-destructive charge counter as well as a sensitive timing circuit. We present the concept and design details of the device. We have characterized its performance and show measurements with low-energy highly charged ions (such as Ar13+) passing through one of the electrodes of a cylindrical Penning trap. This work demonstrates a novel approach of non-destructive, low noise detection of charged particles which is, depending on the bunch structure, suitable, e.g., for ion traps, low-energy beamlines or accelerator transfer sections.

  3. Evaluation of regional pulmonary blood flow in mitral valvular heart disease using single-pass radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Chang-Soon Koh; Byung Tae Kim; Myung Chul Lee; Bo Yeon Cho

    1982-01-01

    Pulmonary hypertension in mitral valvular cardiac disease has been evaluated in 122 patients by a modified upper lung/lower count ratio using single-pass radionuclide angiocardiography. The mean upper lung/lower lung radio correlates well with pulmonary artery mean (r=0.483) and wedge pressure (r=0.804). After correction surgery of the cardiac valve, the ratio decreases and returns to normal range in patients judged clinically to have good surgical benifit. This modified method using single-pass technique provides additional simple, reproducible and nontraumatic results of regional pulmonary blood flow and appears to be correlated with the degree of pulmonary hypertension in mitral heart disease

  4. Absorption Properties of Luteolin and Apigenin in Genkwa Flos Using In Situ Single-Pass Intestinal Perfusion System in the Rat.

    Science.gov (United States)

    He, Xin; Song, Zi-Jing; Jiang, Cui-Ping; Zhang, Chun-Feng

    2017-01-01

    The flower bud of Daphne genkwa (Genkwa Flos) is a commonly used herbal medicine in Asian countries. Luteolin and apigenin are two recognized active flavonoids in Genkwa Flos. The aim of this study was to investigate the intestinal absorption mechanisms of Genkwa Flos flavonoids using in situ single-pass intestinal perfusion rat model. Using HPLC, we determined its major effective flavonoids luteolin, apigenin, as well as, hydroxygenkwanin and genkwanin in biological samples. The intestinal absorption mechanisms of the total flavonoids in Genkwa Flos (TFG) were investigated using in situ single-pass intestinal perfusion rat model. Comparing the TFG absorption rate in different intestinal segments, data showed that the small intestine absorption was significantly higher than that of the colon ([Formula: see text]). Compared with duodenum and ileum, the jejunum was the best small intestinal site for TFG absorption. The high TFG concentration (61.48[Formula: see text][Formula: see text]g/ml) yielded the highest permeability ([Formula: see text]). Subsequently, three membrane protein inhibitors (verapamil, pantoprazole and probenecid) were used to explore the TFG absorption pathways. Data showed probenecid, a multidrug resistance protein (or MRP) inhibitor, effectively enhanced the TFG absorption ([Formula: see text]). Furthermore, by comparing commonly used natural absorption enhancers on TFG, it was observed that camphor was the most effective. In Situ single-pass intestinal perfusion experiment shows that TFG absorption is much higher in the small intestine than in the colon, and the TFG is absorbed mainly via an active transport pathway with MRP-mediated efflux mechanism. Camphor obviously enhanced the TFG absorption, and this could be an effective TFG formulation preparation method to increase clinical effectiveness after Genkwa Flos administration. Our study elucidated the TFG absorption mechanisms, and provided new information for its formulation preparation.

  5. Narrow conductive structures with high aspect ratios through single-pass inkjet printing and evaporation-induced dewetting

    NARCIS (Netherlands)

    Abbel, R.; Teunissen, P.; Michels, J.; Groen, W.A.

    2015-01-01

    Inkjet printed silver lines contract to widths below 20-μm during drying on an organic planarization coating. Aspect ratios previously unprecedented with single pass inkjet printing on isotropic homogeneous substrates are obtained. This effect is caused by the subsequent evaporation of solvents from

  6. Characterization of Al-coated and Uncoated Steel Slags in Flow-through Experiments: An Approach to Evaluate the Potential Efficiency of P Sorption Materials in P Removal Structures

    Science.gov (United States)

    Chagas, I. S. P.; Penn, C. J.; Huang, C. H.

    2017-12-01

    Excessive phosphorus (P) in surface waters is one of the key drivers of eutrophication. P removal structures are an emerging technology developed to reduce excessive dissolved P in runoff and drainage water, preventing or mitigating P delivery to water systems. One of the determining factors for the success of these structures is the type of P sorption material (PSM) being used. Steel slag, a residue of the steel industry, is an example of PSM proven to be efficient in sequestering dissolved P from water. However, its P sorption capacity can significantly vary, mostly because different steel-making processes generate this PSM. Aluminum-coating is a technology aiming to improve the P sorptive qualities of steel slag. In this study, we characterized eighteen different slag samples from different plants and steel-making processes. Safety, i.e., presence of trace metals, as well as chemical and physical properties were evaluated through digestions, metal-extractions and general chemical and physical characterization (e.g.: pH, buffer index, bulk density). We conducted flow-through experiments, a dynamic sorption approach, on coated and uncoated slag samples in order to evaluate differences in P removal efficiency and the effects of Al-coating. For the Al-coating, a solution of Al2(SO4)3 at two concentrations (94.5 or 66.2 g L-1) was used to coat the slag samples. After 48 hours in contact with the solution, flow-through experiments were performed. All samples were tested with an incoming P concentration of 0.5 mg L-1. Hydraulic residence time was regulated for each steel slag sample, alternating between 9.85 minutes or 0.28 minutes. This study will provide essential information about intrinsic differences in steel slag composition and its efficiency in sequestering P from flowing waters. Moreover, we explore the effects of the Al-coating technique, which can in turn enhance P removal structures efficacy and broaden its adoption.

  7. Regional brain blood flow in mouse: quantitative measurement using a single-pass radio-tracer method and a mathematical algorithm.

    Science.gov (United States)

    Xu, K; Radhakrishnan, K; Serhal, A; Allen, F; Lamanna, J C; Puchowicz, M A

    2011-01-01

    We have developed a reliable experimental method for measuring local regional cerebral blood flows in anesthetized mice. This method is an extension of the well-established single-pass dual-label indicator method for simultaneously measuring blood flow and glucose influx in rat brains. C57BL6J mice (n = 10) were anesthetized and regional blood flows (ml/min/g) were measured using the radio-tracer method. To test the sensitivity of this method we used a mathematical algorithm to predict the blood flows and compared the two sets of results.Measured regional blood flows between 0.7 and 1.7 ml/min/g were similar to those we have previously reported in the rat. The predicted blood flows using an assumed linearly increasing arterial tracer concentration-versus-time profile (that is, a ramp) were similar to the values measured in the physiological experiments (R(2) 0.99; slope 0.91). Thus,measurements of local regional cerebral blood flow in anesthetized mice using a single-pass radio-tracer method appear to be reliable.

  8. Modeling of Cavitating Flow through Waterjet Propulsors

    Science.gov (United States)

    2015-02-18

    OCT-11 -31-DEC-14 To) 4. TITLE AND SUBTITLE Modeling of Cavitating Flow through Waterjet Propulsors 5a. CONTRACT NUMBER 5b. GRANT NUMBER N00014-12...239-18 Modeling of Cavitating Flow through Waterjet Propulsors Jules W. Lindau The Pennsylvania State University, Applied Research Laboratory, State...flow nature, waterjets are expected to maintain resistance to cavitation , are amenable to ad- vanced concepts such as thrust vectoring, should

  9. Pressure drop of flow through perforated plate

    International Nuclear Information System (INIS)

    Barros Filho, Jose A.; Navarro, Moyses A.; Magalhaes, Felipe A.P.; Santos, Andre A. Campagnole dos

    2007-01-01

    This paper presents the results of the first part of a research program devised to develop and validate a CFD methodology to simulate the flow of water through perforated plates with geometry similar to the ones of the bottom end piece of a Pressurized Water Reactor. This component drives the coolant into the core, promotes an adequate mixing of dissolved substances and holds the fuel assembly mechanically. It accounts for a great part of the pressure loss through the core. The experimental pressure losses of water flow through 5 different perforated plates are presented here. The profile of the recovering of the pressure right downstream the plates was also measured. The experimental results were compared with numerical modeling performed with the commercial code CFX 10.0. Three different turbulence models of the two equation type were used in the simulations. The analysis of the results shows that the agreement between calculations and experiments decrease for flows with higher disturbance of the current. (author)

  10. Thermo-Mechanical Analysis of a Single-Pass Weld Overlay and Girth Welding in Lined Pipe

    Science.gov (United States)

    Obeid, Obeid; Alfano, Giulio; Bahai, Hamid

    2017-08-01

    The paper presents a nonlinear heat-transfer and mechanical finite-element (FE) analyses of a two-pass welding process of two segments of lined pipe made of a SUS304 stainless steel liner and a C-Mn steel pipe. The two passes consist of the single-pass overlay welding (inner lap weld) of the liner with the C-Mn steel pipe for each segment and the single-pass girth welding (outer butt weld) of the two segments. A distributed power density of the moving welding torch and a nonlinear heat-transfer coefficient accounting for both radiation and convection have been used in the analysis and implemented in user subroutines for the FE code ABAQUS. The modeling procedure has been validated against previously published experimental results for stainless steel and carbon steel welding separately. The model has been then used to determine the isotherms induced by the weld overlay and the girth welding and to clarify their influence on the transient temperature field and residual stress in the lined pipe. Furthermore, the influence of the cooling time between weld overlay and girth welding and of the welding speed have been examined thermally and mechanically as they are key factors that can affect the quality of lined pipe welding.

  11. Bioaugmentation of flow-through sand filters

    DEFF Research Database (Denmark)

    Samuelsen, Elin Djurhuus

    filters with specific degrading bacteria. However, degradation efficiency is often hampered by poor adhesion and a lack of sustained catabolic activity of the introduced bacteria. The overall objective of this thesis was to investigate the significance of selected bacterial surface properties...... for degradation performances in flow-through sand columns, with the aim of identifying a suitable inoculant strain for future environmental applications. Another aim was to identify a suitable genetic marker to monitor phenoxy acid degradation in strain Sphingobium sp. PM2. We were not able to link motility...... and biofilm formation to the strains´ ability to adhere to sand. Nevertheless, a correlation was found between cell surface hydrophobicity and adhesion and overall degradation performances in flow-through sand columns. We identified S phingobium sp. PM2 as a promising inoculant strain, displaying efficient...

  12. Flow-through shares for power development

    International Nuclear Information System (INIS)

    Howie, K.D.

    1999-01-01

    Financial advantages will occur to power producers in Ontario provided that they are innovative in raising capital needed to take advantage of opportunities offered by the Energy Competition Act of 1998. In the new electricity regime, the availability of long term non-recourse debt financing supported by long term power purchasing from Ontario Hydro will probably decrease. The issuance of flow-through shares is a form of financing that could by available to them for certain projects, and there is the probability that greater equity financing will be needed. These flow-through shares can give investors immediate tax savings, a potential favorable return on their equity investment, and a means of financing certain kinds of power projects

  13. Wind flow through shrouded wind turbines

    Science.gov (United States)

    2017-03-01

    velocity and model angle were varied . Additionally, static wall pressures and cross section flow were studied with the addition of a screen. The pressure...the geometry of a wind lens or flange on the shroud and a gradually diverging shape, proved to accelerate the flow through the duct. 14. SUBJECT...Tunnel velocity and model angle were varied . Additionally, static wall pressures and cross section flow were studied with the addition of a screen. The

  14. Single Pass Laser Welding with Multiple Spots to Join Four Sheets in a Butt-joint Configuration

    Science.gov (United States)

    Kristiansen, Morten; Hansen, Klaus Schütt; Langbak, Andreas; Johansen, Sebastian Blegebrønd; Krempin, Simon Borup; Hornum, Mattias Døssing

    Laser keyhole welding is widely used in industry due to its large welding depth and low heat input. For some industrial cases it is necessary to widen the beam to cover the joint configuration, which instead results in a lower intensity and surface conduction welds. The introduction of the high-power single mode fiber laser makes it possible to deal with this problem, because the beam can be shaped into a pre-defined pattern of multiple spots shaped to the actual joint configuration. The intensity of each spot is sufficient to make a keyhole. A case with four sheets in a butt-joint configuration is used to demonstrate the principle of how to design a spot pattern which ensures weld quality in case of a single pass laser weld.

  15. Lucretia A Matlab-Based Toolbox for the Modeling and Simulation of Single-Pass Electron Beam Transport Systems

    CERN Document Server

    Tenenbaum, P G

    2005-01-01

    We report on Lucretia, a new simulation tool for the study of single-pass electron beam transport systems. Lucretia supports a combination of analytic and tracking techniques to model the tuning and operation of bunch compressors, linear accelerators, and beam delivery systems of linear colliders and linac-driven Free Electron Laser (FEL) facilities. Extensive use of Matlab scripting, graphics, and numerical capabilities maximize the flexibility of the system, and emphasis has been placed on representing and preserving the fixed relationships between elements (common girders, power supplies, etc.) which must be respected in the design of tuning algorithms. An overview of the code organization, some simple examples, and plans for future development are discussed.

  16. Testing the single-pass VOC removal efficiency of an active green wall using methyl ethyl ketone (MEK).

    Science.gov (United States)

    Torpy, Fraser; Clements, Nicholas; Pollinger, Max; Dengel, Andy; Mulvihill, Isaac; He, Chuan; Irga, Peter

    2018-01-01

    In recent years, research into the efficacy of indoor air biofiltration mechanisms, notably living green walls, has become more prevalent. Whilst green walls are often utilised within the built environment for their biophilic effects, there is little evidence demonstrating the efficacy of active green wall biofiltration for the removal of volatile organic compounds (VOCs) at concentrations found within an interior environment. The current work describes a novel approach to quantifying the VOC removal effectiveness by an active living green wall, which uses a mechanical system to force air through the substrate and plant foliage. After developing a single-pass efficiency protocol to understand the immediate effects of the system, the active green wall was installed into a 30-m 3 chamber representative of a single room and presented with the contaminant 2-butanone (methyl ethyl ketone; MEK), a VOC commonly found in interior environments through its use in textile and plastic manufacture. Chamber inlet levels of MEK remained steady at 33.91 ± 0.541 ppbv. Utilising a forced-air system to draw the contaminated air through a green wall based on a soil-less growing medium containing activated carbon, the combined effects of substrate media and botanical component within the biofiltration system showed statistically significant VOC reduction, averaging 57% single-pass removal efficiency over multiple test procedures. These results indicate a high level of VOC removal efficiency for the active green wall biofilter tested and provide evidence that active biofiltration may aid in reducing exposure to VOCs in the indoor environment.

  17. Gas and Oil Flow through Wellbore Flaws

    Science.gov (United States)

    Hatambeigi, M.; Anwar, I.; Reda Taha, M.; Bettin, G.; Chojnicki, K. N.; Stormont, J.

    2017-12-01

    We have measured gas and oil flow through laboratory samples that represent two important potential flow paths in wellbores associated with the Strategic Petroleum Reserve (SPR): cement-steel interfaces (microannuli) and cement fractures. Cement fractures were created by tensile splitting of cement cores. Samples to represent microannuli were created by placing thin steel sheets within split cement cores so flow is channeled along the cement-steel interface. The test sequence included alternating gas and oil flow measurements. The test fluids were nitrogen and silicone oil with properties similar to a typical crude oil stored in the SPR. After correcting for non-linear (inertial) flow when necessary, flows were interpreted as effective permeability and hydraulic aperture using the cubic law. For both samples with cement fractures and those with cement-steel interfaces, initial gas and oil permeabilities were comparable. Once saturated with oil, a displacement pressure had to be overcome to establish gas flow through a sample, and the subsequent gas permeability were reduced by more than 50% compared to its initial value. Keywords: wellbore integrity, leakage, fracture, microannulus, SPR. Sandia National Laboratories is a multi-mission laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of NTESS/Honeywell, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000. SAND2017-8168 A

  18. Fluid flow through anisotropic porous medium

    International Nuclear Information System (INIS)

    Telles, A.S.; Massarani, G.

    1975-01-01

    Darcy's equation represents a simplified form of the equation of motion for the fluid flowing through a porous medium. The simplifications concern the elimination of the acceleration, the divergence of the extra stress terms, and the assumption of existence of a linear form in the velocity for the resistive force the fluid exerts upon the solid. This hypothesis may not be valid for all anisotropic media. In some instances, measurements of directional resistivity suggest existence of the resistivity tensor, leaving entirely open the question of symmetry. In connection with this important question, an experimental scheme for the determination of the antisymmetric part of this tensor is suggested. The conclusion is that material symmetries is the only macroscopic concept that imposes restrictions on the form of the resistivity and extra stress tensors [pt

  19. Absorption characteristics of the total alkaloids from Mahonia bealei in an in situ single-pass intestinal perfusion assay.

    Science.gov (United States)

    Sun, Yu-He; He, Xin; Yang, Xiao-Lin; Dong, Cui-Lan; Zhang, Chun-Feng; Song, Zi-Jing; Lu, Ming-Xing; Yang, Zhong-Lin; Li, Ping

    2014-07-01

    To investigate the absorption characteristics of the total alkaloids from Mahoniae Caulis (TAMC) through the administration of monterpene absorption enhancers or protein inhibitors. The absorption behavior was investigated in an in situ single-pass intestinal perfusion (SPIP) assay in rats. The intestinal absorption of TAMC was much more than that of a single compound or a mixture of compounds (jatrorrhizine, palmatine, and berberine). Promotion of absorption by the bicyclic monoterpenoids (borneol or camphor) was higher than by the monocyclic monoterpenes (menthol or menthone), and promotion by compounds with a hydroxyl group (borneol or menthol) was higher than those with a carbonyl group (camphor or menthone). The apparent permeability coefficient (Papp) of TAMC was increased to 1.8-fold by verapamil, while it was reduced to one half by thiamine. The absorption rate constant (Ka) and Papp of TAMC were unchanged by probenecid and pantoprazole. The intestinal absorption characteristics of TAMC might be passive transport, and the intestinum tenue was the best absorptive site. In addition, TAMC might be likely a substrate of P-glycoprotein (P-gp) and organic cation transporters (OCT), rather than multidrug resistance protein (MRP) and breast cancer resistance protein (BCRP). Compared with a single compound and a mixture of compounds, TAMC was able to be absorbed in the blood circulation effectively. Copyright © 2014 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.

  20. Sea ice local surface topography from single-pass satellite InSAR measurements: a feasibility study

    Directory of Open Access Journals (Sweden)

    W. Dierking

    2017-08-01

    Full Text Available Quantitative parameters characterizing the sea ice surface topography are needed in geophysical investigations such as studies on atmosphere–ice interactions or sea ice mechanics. Recently, the use of space-borne single-pass interferometric synthetic aperture radar (InSAR for retrieving the ice surface topography has attracted notice among geophysicists. In this paper the potential of InSAR measurements is examined for several satellite configurations and radar frequencies, considering statistics of heights and widths of ice ridges as well as possible magnitudes of ice drift. It is shown that, theoretically, surface height variations can be retrieved with relative errors  ≤  0.5 m. In practice, however, the sea ice drift and open water leads may contribute significantly to the measured interferometric phase. Another essential factor is the dependence of the achievable interferometric baseline on the satellite orbit configurations. Possibilities to assess the influence of different factors on the measurement accuracy are demonstrated: signal-to-noise ratio, presence of a snow layer, and the penetration depth into the ice. Practical examples of sea surface height retrievals from bistatic SAR images collected during the TanDEM-X Science Phase are presented.

  1. {open_quotes}Optical guiding{close_quotes} limits on extraction efficiencies of single-pass, tapered wiggler amplifiers

    Energy Technology Data Exchange (ETDEWEB)

    Fawley, W.M. [Lawrence Berkeley Lab., CA (United States)

    1995-12-31

    Single-pass, tapered wiggler amplifiers have an attractive feature of being able, in theory at least, of extracting a large portion of the electron beam energy into light. In circumstances where an optical FEL`s wiggler length is significantly longer than the Rayleigh length Z{sub R} corresponding to the electron beam radius, diffraction losses must be controlled via the phenomenon of {open_quotes}optical guiding{close_quotes}. Since the strength of the guiding depends upon the effective refractive index {eta}{sub r} exceeding one, and since ({eta}{sub r}-1) is inversely proportional to the optical electric field, there is a natural {open_quotes}limiting{close_quotes} mechanism to the on-axis field strength and thus the rate at which energy may be extracted from the electron beam. In particular, the extraction efficiency for a prebunched beam asymptotically grows linearly with z rather than quadratically. We present analytical and numerical simulation results concerning this behavior and discuss its applicability to various FEL designs including oscillator/amplifier-radiator configurations.

  2. A 3D Reconstruction Strategy of Vehicle Outline Based on Single-Pass Single-Polarization CSAR Data.

    Science.gov (United States)

    Leping Chen; Daoxiang An; Xiaotao Huang; Zhimin Zhou

    2017-11-01

    In the last few years, interest in circular synthetic aperture radar (CSAR) acquisitions has arisen as a consequence of the potential achievement of 3D reconstructions over 360° azimuth angle variation. In real-world scenarios, full 3D reconstructions of arbitrary targets need multi-pass data, which makes the processing complex, money-consuming, and time expending. In this paper, we propose a processing strategy for the 3D reconstruction of vehicle, which can avoid using multi-pass data by introducing a priori information of vehicle's shape. Besides, the proposed strategy just needs the single-pass single-polarization CSAR data to perform vehicle's 3D reconstruction, which makes the processing much more economic and efficient. First, an analysis of the distribution of attributed scattering centers from vehicle facet model is presented. And the analysis results show that a smooth and continuous basic outline of vehicle could be extracted from the peak curve of a noncoherent processing image. Second, the 3D location of vehicle roofline is inferred from layover with empirical insets of the basic outline. At last, the basic line and roofline of the vehicle are used to estimate the vehicle's 3D information and constitute the vehicle's 3D outline. The simulated and measured data processing results prove the correctness and effectiveness of our proposed strategy.

  3. Single-frequency blue light generation by single-pass sum-frequency generation in a coupled ring cavity tapered laser

    DEFF Research Database (Denmark)

    Jensen, Ole Bjarlin; Petersen, Paul Michael

    2013-01-01

    A generic approach for generation of tunable single frequency light is presented. 340 mW of near diffraction limited, single-frequency, and tunable blue light around 459 nm is generated by sum-frequency generation (SFG) between two tunable tapered diode lasers. One diode laser is operated in a ring...... cavity and another tapered diode laser is single-passed through a nonlinear crystal which is contained in the coupled ring cavity. Using this method, the single-pass conversion efficiency is more than 25%. In contrast to SFG in an external cavity, the system is entirely self-stabilized with no electronic...

  4. Ion-exchange reactions on clay minerals coupled with advection/dispersion processes. Application to Na+/Ca2+ exchange on vermiculite: Reactive-transport modeling, batch and stirred flow-through reactor experiments

    Science.gov (United States)

    Tertre, E.; Hubert, F.; Bruzac, S.; Pacreau, M.; Ferrage, E.; Prêt, D.

    2013-07-01

    The present study aims at testing the validity of using an Na+/Ca2+ ion-exchange model, derived from batch data to interpret experimental Ca2+-for-Na+ exchange breakthrough curves obtained on vermiculite (a common swelling clay mineral in surface environments). The ion-exchange model was constructed considering the multi-site nature of the vermiculite surface as well as the exchange of all aqueous species (Mg2+ derived from the dissolution of the solid and H+). The proposed ion-exchange model was then coupled with a transport model, and the predicted breakthrough curves were compared with the experimental ones obtained using a well stirred flow-through reactor. For a given solute residence time in the reactor (typically 50 min), our thermodynamic model based on instantaneous equilibrium was found to accurately reproduce several of the experimental breakthrough curves, depending on the Na+ and Ca2+ concentrations of the influents pumped through the reactor. However the model failed to reproduce experimental breakthrough curves obtained at high flow rates and low chemical gradient between the exchanger phase and the solution. An alternative model based on a hybrid equilibrium/kinetic approach was thus used and allowed predicting experimental data. Based on these results, we show that a simple parameter can be used to differentiate between thermodynamic and kinetic control of the exchange reaction with water flow. The results of this study are relevant for natural systems where two aquatic environments having contrasted chemistries interact. Indeed, the question regarding the attainment of a full equilibrium in such a system during the contact time of the aqueous phase with the particle/colloid remains most often open. In this context, we show that when a river (a flow of fresh water) encounters marine colloids, a systematic full equilibrium can be assumed (i.e., the absence of kinetic effects) when the residence time of the solute in 1 m3 of the system is ⩾6200 h.

  5. Balancing Radiation and Contrast Media Dose in Single-Pass Abdominal Multidetector CT: Prospective Evaluation of Image Quality.

    Science.gov (United States)

    Camera, Luigi; Romano, Federica; Liccardo, Immacolata; Liuzzi, Raffaele; Imbriaco, Massimo; Mainenti, Pier Paolo; Pizzuti, Laura Micol; Segreto, Sabrina; Maurea, Simone; Brunetti, Arturo

    2015-11-01

    As both contrast and radiation dose affect the quality of CT images, a constant image quality in abdominal contrast-enhanced multidetector computed tomography (CE-MDCT) could be obtained balancing radiation and contrast media dose according to the age of the patients. Seventy-two (38 Men; 34 women; aged 20-83 years) patients underwent a single-pass abdominal CE-MDCT. Patients were divided into three different age groups: A (20-44 years); B (45-65 years); and C (>65 years). For each group, a different noise index (NI) and contrast media dose (370 mgI/mL) was selected as follows: A (NI, 15; 2.5 mL/kg), B (NI, 12.5; 2 mL/kg), and C (NI, 10; 1.5 mL/kg). Radiation exposure was reported as dose-length product (DLP) in mGy × cm. For quantitative analysis, signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were calculated for both the liver (L) and the abdominal aorta (A). Statistical analysis was performed with a one-way analysis of variance. Standard imaging criteria were used for qualitative analysis. Although peak hepatic enhancement was 152 ± 16, 128 ± 12, and 101 ± 14 Hounsfield units (P contrast media dose (mL) administered were 476 ± 147 and 155 ± 27 for group A, 926 ± 291 and 130 ± 16 for group B, and 1981 ± 451 and 106 ± 15 for group C, respectively (P contrast media dose administered to patients of different age. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  6. Single-pass Airborne InSAR for Wide-swath, High-Resolution Cryospheric Surface Topography Mapping

    Science.gov (United States)

    Moller, D.; Hensley, S.; Wu, X.; Muellerschoen, R.

    2014-12-01

    In May 2009 a mm-wave single-pass interferometric synthetic aperture radar (InSAR) for the first time demonstrated ice surface topography swath-mapping in Greenland. This was achieved with the airborne Glacier and Ice Surface Topography Interferometer (GLISTIN-A). Ka-band (35.6GHz) was chosen for high-precision topographic mapping from a compact sensor with minimal surface penetration. In recent years, the system was comprehensively upgraded for improved performance, stability and calibration. In April 2013, after completing the upgrades, GLISTIN-A flew a brief campaign to Alaska. The primary purpose was to demonstrate the InSAR's ability to generate high-precision, high resolution maps of ice surface topography with swaths in excess of 10km. Comparison of GLISTIN-A's elevations over glacial ice with lidar verified the precision requirements and established elevation accuracies to within 2 m without tie points. Feature tracking of crevasses on Columbia Glacier using data acquired with a 3-day separation exhibit an impressive velocity mapping capability. Furthermore, GLISTIN-A flew over the Beaufort sea to determine if we could not only map sea ice, but also measure freeboard. Initial analysis has established we can measure sea-ice freeboard using height differences from the top of the sea-ice and the sea surface in open leads. In the future, a campaign with lidar is desired for a quantitative validation. Another proof-of-concept collection mapped snow-basins for hydrology. Snow depth measurements using summer and winter collections in the Sierras were compared with lidar measurements. Unsurprisingly when present, trees complicate the interpretation, but additional filtering and processing is in work. For each application, knowledge of the interferometric penetration is important for scientific interpretation. We present analytical predictions and experimental data to upper bound the elevation bias of the InSAR measurements over snow and snow-covered ice.

  7. Single Pass Albumin Dialysis-A Dose-Finding Study to Define Optimal Albumin Concentration and Dialysate Flow.

    Science.gov (United States)

    Schmuck, Rosa Bianca; Nawrot, Gesa-Henrike; Fikatas, Panagiotis; Reutzel-Selke, Anja; Pratschke, Johann; Sauer, Igor Maximilian

    2017-02-01

    Several artificial liver support concepts have been evaluated both in vitro and clinically. Single pass albumin dialysis (SPAD) has shown to be one of the most simple approaches for removing albumin-bound toxins and water-soluble substances. Being faced with acute liver failure (ALF) in everyday practice encouraged our attempt to define the optimal conditions for SPAD more precisely in a standardized experimental setup. Albumin concentration was adjusted to either 1%, 2%, 3%, or 4%, while the flow rate of the dialysate was kept constant at a speed of 700 mL/h. The flow rate of the dialysate was altered between 350, 500, 700, and 1000 mL/h, whereas the albumin concentration was continuously kept at 3%. This study revealed that the detoxification of albumin-bound substances could be improved by increasing the concentration of albumin in the dialysate with an optimum at 3%. A further increase of the albumin concentration to 4% did not lead to a significant increase in detoxification. Furthermore, we observed a gradual increase of the detoxification efficiency for albumin-bound substances, from 350 mL/h to 700 mL/h (for bilirubin) or 1000 mL/h (for bile acids) of dialysate flow. Water-soluble toxins (ammonia, creatinine, urea, uric acid) were removed almost completely, regardless of albumin concentration or flow rate. In conclusion, this study confirmed that SPAD is effective in eliminating albumin-bound as well as water-soluble toxins using a simulation of ALF. Furthermore, this project was successful in evaluating the most effective combination of albumin concentration (3%) and dialysate flow (700 mL/h-1000 mL/h) in SPAD for the first time. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  8. Double Pass 595?nm pulsed dye laser at a 6 minute interval for the treatment of port-wine stains is not more effective than single pass

    NARCIS (Netherlands)

    Peters, M. A. D.; van Drooge, A. M.; Wolkerstorfer, A.; van Gemert, M. J. C.; van der Veen, J. P. W.; Bos, J. D.; Beek, J. F.

    2012-01-01

    Background Pulsed dye laser (PDL) is the first choice for treatment of port wine stains (PWS). However, outcome is highly variable and only a few patients achieve complete clearance. The objective of the study was to compare efficacy and safety of single pass PDL with double pass PDL at a 6 minute

  9. Atlantic water flow through the Faroese Channels

    Directory of Open Access Journals (Sweden)

    B. Hansen

    2017-11-01

    Full Text Available Through the Faroese Channels – the collective name for a system of channels linking the Faroe–Shetland Channel, Wyville Thomson Basin, and Faroe Bank Channel – there is a deep flow of cold waters from Arctic regions that exit the system as overflow through the Faroe Bank Channel and across the Wyville Thomson Ridge. The upper layers, in contrast, are dominated by warm, saline water masses from the southwest, termed Atlantic water. In spite of intensive research over more than a century, there are still open questions on the passage of these waters through the system with conflicting views in recent literature. Of special note is the suggestion that there is a flow of Atlantic water from the Faroe–Shetland Channel through the Faroe Bank Channel, which circles the Faroes over the slope region in a clockwise direction. Here, we combine the observational evidence from ship-borne hydrography, moored current measurements, surface drifter tracks, and satellite altimetry to address these questions and propose a general scheme for the Atlantic water flow through this channel system. We find no evidence for a continuous flow of Atlantic water from the Faroe–Shetland Channel to the Faroe Bank Channel over the Faroese slope. Rather, the southwestward-flowing water over the Faroese slope of the Faroe–Shetland Channel is totally recirculated within the combined area of the Faroe–Shetland Channel and Wyville Thomson Basin, except possibly for a small release in the form of eddies. This does not exclude a possible westward flow over the southern tip of the Faroe Shelf, but even including that, we estimate that the average volume transport of a Circum-Faroe Current does not exceed 0.5 Sv (1 Sv  =  106 m3 s−1. Also, there seems to be a persistent flow of Atlantic water from the western part of the Faroe Bank Channel into the Faroe–Shetland Channel that joins the Slope Current over the Scottish slope. These conclusions will affect

  10. Atlantic water flow through the Faroese Channels

    Science.gov (United States)

    Hansen, Bogi; Poulsen, Turið; Margretha Húsgarð Larsen, Karin; Hátún, Hjálmar; Østerhus, Svein; Darelius, Elin; Berx, Barbara; Quadfasel, Detlef; Jochumsen, Kerstin

    2017-11-01

    Through the Faroese Channels - the collective name for a system of channels linking the Faroe-Shetland Channel, Wyville Thomson Basin, and Faroe Bank Channel - there is a deep flow of cold waters from Arctic regions that exit the system as overflow through the Faroe Bank Channel and across the Wyville Thomson Ridge. The upper layers, in contrast, are dominated by warm, saline water masses from the southwest, termed Atlantic water. In spite of intensive research over more than a century, there are still open questions on the passage of these waters through the system with conflicting views in recent literature. Of special note is the suggestion that there is a flow of Atlantic water from the Faroe-Shetland Channel through the Faroe Bank Channel, which circles the Faroes over the slope region in a clockwise direction. Here, we combine the observational evidence from ship-borne hydrography, moored current measurements, surface drifter tracks, and satellite altimetry to address these questions and propose a general scheme for the Atlantic water flow through this channel system. We find no evidence for a continuous flow of Atlantic water from the Faroe-Shetland Channel to the Faroe Bank Channel over the Faroese slope. Rather, the southwestward-flowing water over the Faroese slope of the Faroe-Shetland Channel is totally recirculated within the combined area of the Faroe-Shetland Channel and Wyville Thomson Basin, except possibly for a small release in the form of eddies. This does not exclude a possible westward flow over the southern tip of the Faroe Shelf, but even including that, we estimate that the average volume transport of a Circum-Faroe Current does not exceed 0.5 Sv (1 Sv = 106 m3 s-1). Also, there seems to be a persistent flow of Atlantic water from the western part of the Faroe Bank Channel into the Faroe-Shetland Channel that joins the Slope Current over the Scottish slope. These conclusions will affect potential impacts from offshore activities in the

  11. The influence of following on bidirectional flow through a doorway

    Science.gov (United States)

    Graves, Amy; Diamond, Rachel; Saakashvili, Eduard

    Pedestrian dynamics is a subset of the study of self-propelled particles. We simulate two species of pedestrians undergoing bidirectional flow through a narrow doorway. Using the Helbing-Monlár-Farkas-Vicsek Social Force Model, our pedestrians are soft discs that experience psychosocial and physical contact forces. We vary the ``following'' parameter which determines the degree to which a pedestrian matches its direction of movement to the average of nearby, same-species pedestrians. Current density, efficiency and statistics of bursts and lags are calculated. These indicate that choosing different following parameters for each species affects the efficacy of transport - greater following being associated with lower efficacy. The information entropy associated with velocity and the long time tails of the complementary CDF of lag times are additional indicators of the dynamical consequences of following during bidirectional flow. Acknowledgement is made to the donors of the ACS Petrolium Research Fund, and the Vandervelde-Cheung Fund of Swarthmore College.

  12. Loss Prediction of Low Re Flow Through Quasiperiodic Serpentine Channels

    Science.gov (United States)

    Becker, Sid

    2017-11-01

    Low Re internal flow through a complex structure whose geometry is regular (periodically uniform) will experience losses that are periodically regular and may be predicted using simple correlations. In many porous media applications this is represented by Darcy's Law. This study considers the prediction of losses through a channel whose geometry is periodic but with characteristic length scales that vary in the direction of bulk flow. Asymptotic expansions of the variation in the characteristic length are implemented in flow simulations in order to determine a correlation relating local hydraulic permeability to local channel geometry. In this way the local losses may be predicted without requiring the explicit solution of the flow field for every specific channel geometry. Several test cases are presented showing that using these correlations, the local pressure losses may predicted to within 0.5% agreement with the solution to the Navier-Stokes Equations.

  13. Atrial electrogram quality in single-pass defibrillator leads with floating atrial bipole in patients with permanent atrial fibrillation and cardiac resynchronization therapy.

    Science.gov (United States)

    Sticherling, Christian; Müller, Dirk; Schaer, Beat A; Krüger, Silke; Kolb, Christof

    2018-03-27

    Many patients receiving cardiac resynchronization therapy (CRT) suffer from permanent atrial fibrillation (AF). Knowledge of the atrial rhythm is important to direct pharmacological or interventional treatment as well as maintaining AV-synchronous biventricular pacing if sinus rhythm can be restored. A single pass single-coil defibrillator lead with a floating atrial bipole has been shown to obtain reliable information about the atrial rhythm but has never been employed in a CRT-system. The purpose of this study was to assess the feasibility of implanting a single coil right ventricular ICD lead with a floating atrial bipole and the signal quality of atrial electrograms (AEGM) in CRT-defibrillator recipients with permanent AF. Seventeen patients (16 males, mean age 73 ± 6 years, mean EF 25 ± 5%) with permanent AF and an indication for CRT-defibrillator placement were implanted with a designated CRT-D system comprising a single pass defibrillator lead with a atrial floating bipole. They were followed-up for 103 ± 22 days using remote monitoring for AEGM transmission. All patients had at last one AEGM suitable for atrial rhythm diagnosis and of 100 AEGM 99% were suitable for visual atrial rhythm assessment. Four patients were discharged in sinus rhythm and one reverted to AF during follow-up. Atrial electrograms retrieved from a single-pass defibrillator lead with a floating atrial bipole can be reliably used for atrial rhythm diagnosis in CRT recipients with permanent AF. Hence, a single pass ventricular defibrillator lead with a floating bipole can be considered in this population. Copyright © 2018 Indian Heart Rhythm Society. Production and hosting by Elsevier B.V. All rights reserved.

  14. Pressure drop in flashing flow through obstructions

    International Nuclear Information System (INIS)

    Weinle, M.E.; Johnston, B.S.

    1985-01-01

    An experiment was designed to investigate the pressure drop for flashing flow across obstructions of different geometries at various flow rates. Tests were run using two different orifices to determine if the two-phase pressure drop could be characterized by the single phase loss coefficient and the general behavior of the two-phase multiplier. For the geometries studied, it was possible to correlate the multiplier in a geometry-independent fashion

  15. Transient gas flow through layered porous media

    International Nuclear Information System (INIS)

    Morrison, F.A. Jr.

    1975-01-01

    Low Reynolds number isothermal flow of an ideal gas through layered porous material was investigated analytically. Relations governing the transient flow in one dimension are obtained. An implicit, iterative, unconditionally stable finite difference scheme is developed for calculation of such flows. A computer code, SIROCCO, employing this technique has been written and implemented on the LLL computer system. A listing of the code is included. This code may be effectively applied to the evaluation of stemming plans for underground nuclear experiments. (U.S.)

  16. Flow through a Two-Scale Porosity Material

    Directory of Open Access Journals (Sweden)

    A. G. Andersson

    2009-01-01

    Full Text Available Flow through a two-scale porous medium is here investigated by a unique comparison between simulations performed with computational fluid dynamics and the boundary element method with microparticle image velocimetry in model geometries.

  17. Experimental study of flow through compressor Cascade

    Directory of Open Access Journals (Sweden)

    Satyam Panchal

    2017-09-01

    Full Text Available The objective of this research work is to study the behaviour of flow at the inlet, within the blade passage and at the exit of a compressor cascade. For this purpose, a cascade with six numbers of aerofoil blades was designed and constructed. The cascade was fitted on the cascade test tunnel. Out of six blades two were instrumented for measuring the pressure distribution on the pressure and suction surface. The blades had a parabolic camber line, with a maximum camber position at 40% of the chord from the leading edge of the blade. The profile of the blade was C4, height of the blade was 160 mm, chord length was 80 mm, camber angle was 45° and stagger angle was 30°. Similarly, the length of the cascade was 300 mm, span was 160 mm, pitch was 60 mm, the actual chord of the cascade was 80 mm, the axial chord of the cascade was 70 mm, the stagger angle of the cascade was 30° and the pitch-chord ratio was 0.75. The data was taken and analyzed at −500% of the axial chord before the cascade, −25% of the axial chord before the leading edge, 25%, 50%, 75% and 150% of the axial chord from the leading edge of the blade. The readings were taken from the cascade wall to the mid span position along the pitch wise direction. The angle of incidence was also changed during the experiment and varied from i=−50°, −30°, −10° to 5°.

  18. A Unified Algorithm for Channel Imbalance and Antenna Phase Center Position Calibration of a Single-Pass Multi-Baseline TomoSAR System

    Directory of Open Access Journals (Sweden)

    Yuncheng Bu

    2018-03-01

    Full Text Available The multi-baseline synthetic aperture radar (SAR tomography (TomoSAR system is employed in such applications as disaster remote sensing, urban 3-D reconstruction, and forest carbon storage estimation. This is because of its 3-D imaging capability in a single-pass platform. However, a high 3-D resolution of TomoSAR is based on the premise that the channel imbalance and antenna phase center (APC position are precisely known. If this is not the case, the 3-D resolution performance will be seriously degraded. In this paper, a unified algorithm for channel imbalance and APC position calibration of a single-pass multi-baseline TomoSAR system is proposed. Based on the maximum likelihood method, as well as the least squares and the damped Newton method, we can calibrate the channel imbalance and APC position. The algorithm is suitable for near-field conditions, and no phase unwrapping operation is required. The effectiveness of the proposed algorithm has been verified by simulation and experimental results.

  19. Investigating drug absorption from the colon: Single-pass vs. Doluisio approaches to in-situ rat large-intestinal perfusion.

    Science.gov (United States)

    Lozoya-Agullo, Isabel; Zur, Moran; Fine-Shamir, Noa; Markovic, Milica; Cohen, Yael; Porat, Daniel; González-Álvarez, Isabel; González-Álvarez, Marta; Merino-Sanjuán, Matilde; Bermejo, Marival; Dahan, Arik

    2017-07-15

    Traditionally, the colon is considered a secondary intestinal segment in the drug absorption process. However, in many cases the role of colonic drug permeability cannot be overlooked. The purpose of this research was to compare colon permeability data obtained using two different rat perfusion methods the single-pass intestinal perfusion (SPIP) approach and the closed-loop (Doluisio) perfusion model. A list of 14 structurally diverse model drugs was constructed, and their rat colon permeability was studied using the two methods. The two sets of results were compared to each other, and were evaluated vs. in-vitro, ex-vivo, and in-vivo literature values. The SPIP and the Doluisio results exhibited good correlation between them (R 2 =0.81). The best correlation of both sets was obtained with transport studies across Caco-2 monolayers (R 2 ∼0.9), as well as the sigmoidal fit vs. human fraction of dose absorbed (F abs ) data. On the other hand, Ussing chambers data, as well as lipophilicity (Log P) data, resulted in weak correlation to the in-situ results. In conclusion, the single-pass intestinal perfusion (SPIP) and the Doluisio (closed-loop) perfusion models were found to be equally convenient and useful for obtaining validated colon permeability values, although more human colonic F abs data are needed for a better understanding of colonic drug permeability and absorption. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Characterization of the solid, airborne materials created when UF6 reacts with moist air flowing in single-pass mode

    International Nuclear Information System (INIS)

    Pickrell, P.W.

    1985-10-01

    A series of experiments has been performed in which UF 6 was released into flowing air in order to characterize the solid particulate material produced under non-static conditions. In two of the experiments, the aerosol was allowed to stagnate in a static chamber after release and examined further but in the other experiments characterization was done only on material collected a few seconds after release. Transmission electron microscopy and mass measurement by cascaded impactor were used to characterize the aerosol particles which were usually single spheroids with little agglomeration in evidence. The goal of the work is to determine the chemistry and physics of the UF 6 -atmospheric moisture reaction under a variety of conditions so that information about resulting species and product morphologies is available for containment and removal (knockdown) studies as well as for dispersion plume modeling and toxicology studies. This report completes the milestone for reporting the information obtained from releases of UF 6 into flowing rather than static air. 26 figs., 3 tabs

  1. Boundary control of fluid flow through porous media

    DEFF Research Database (Denmark)

    Hasan, Agus; Foss, Bjarne; Sagatun, Svein Ivar

    2010-01-01

    The flow of fluids through porous media can be described by the Boussinesq’s equation with mixed boundary conditions; a Neumann’s boundary condition and a nonlinear boundary condition. The nonlinear boundary condition provides a means to control the fluid flow through porous media. In this paper...

  2. Modelling flow through unsaturated zones: Sensitivity to unsaturated ...

    Indian Academy of Sciences (India)

    M. Senthilkumar (Newgen Imaging) 1461 1996 Oct 15 13:05:22

    MS received 13 October 1997; revised 20 November 2001. Abstract. A numerical model to simulate moisture flow through unsaturated zones is developed using the finite element method, and is validated by comparing the model results with those available in the literature. The sensitivities of different processes such as ...

  3. A flow-through amperometric sensor micro-analytical systems

    NARCIS (Netherlands)

    Pijanowska, D.; Pijanowska, D.G.; Sprenkels, A.J.; Olthuis, Wouter; Bergveld, Piet

    2003-01-01

    In this paper, the performance of the flow-through amperometric sensor based on semi-permeable dialysis tubing implemented in silicon is presented. The sensor is designed in the form to be an integral component of a lab-on-a-chip systems and it has been successfully incorporated into an integrated

  4. Flow-through microsensor array based on semipermeable dialysis tubing

    Science.gov (United States)

    Bohm, Sebastian; Olthuis, Wouter; Bergveld, Piet

    1999-11-01

    In this contribution, a flow-through potentiometric micro sensor is described which is based on semi-permeable tubing. Basically the proposed ion selective electrodes are of the liquid membrane type having an internal electrolyte. Sensors were constructed by guiding 0.3 mm diameter dialysis tube from an artificial kidney through a cavity, precision machined in PerspexTM.

  5. Modelling flow through unsaturated zones: Sensitivity to unsaturated ...

    Indian Academy of Sciences (India)

    M. Senthilkumar (Newgen Imaging) 1461 1996 Oct 15 13:05:22

    water flow through unsaturated zones and study the effect of unsaturated soil parameters on water movement during different processes such as gravity drainage and infiltration. 2. Modelling Richards equation for vertical unsaturated flow. For one-dimensional vertical flow in unsaturated soil, the pressure-head based ...

  6. Stability of Armour Units in Flow Through a Layer

    DEFF Research Database (Denmark)

    Burcharth, Hans F.; C. Thompson, Alex

    1984-01-01

    As part of a program to study the hydraulics of wave attack on rubble mound breakwaters tests were made on model armour units in a steady flow through a layer laid on a slope. The flow angle has little effect on stability for dolosse or rock layers. The head drop at failure across each type...

  7. Experimental studies on the flow through soft tubes and channels

    Indian Academy of Sciences (India)

    studies were designed to examine whether the compliance of dolphin skins could cause either transition delay, that is, an increase in the Reynolds number for laminar-turbulent transition or a reduction in the turbulence intensities. The first experimental studies on internal flows through conduits bounded by soft walls was.

  8. Flow Through A Horizontal Porous Channel With A Harmonic ...

    African Journals Online (AJOL)

    In this research work we provide a finite element solution to the problem of the flow through a horizontal channel with a harmonic pressure gradient. Results obtained shows that the velocity and temperature increases with time and that a turning point occurs in the temperature profile due to the viscous dissipation effect.

  9. Hydraulic flow through a channel contraction: multiple steady states

    NARCIS (Netherlands)

    Akers, B.; Bokhove, Onno

    2008-01-01

    We have investigated shallow water flows through a channel with a contraction by experimental and theoretical means. The horizontal channel consists of a sluice gate and an upstream channel of constant width $b_0$ ending in a linear contraction of minimum width $b_c$. Experimentally, we observe

  10. Hydraulic flow through a contraction: multiple steady states

    NARCIS (Netherlands)

    Akers, B.; Bokhove, Onno

    We consider shallow water flows through a channel with a contraction by experimental and theoretical means. The horizontal channel consists of a sluice gate and an upstream channel of constant width $b_0$ ending in a linear contraction of minimum width $b_c$. Experimentally, we observe upstream

  11. Stability of fluid flow through deformable tubes and channels: An ...

    Indian Academy of Sciences (India)

    S¯adhan¯a Vol. 40, Part 3, May 2015, pp. 925–943. c Indian Academy of Sciences. Stability of fluid flow through deformable tubes and channels: An overview ... tic solid models. All these studies predict several types of instabilities in flow past deformable surfaces. This paper will attempt to place the various theoretical ...

  12. Modeling of air flow through a narrow crack

    International Nuclear Information System (INIS)

    Trojek, T.; Cechak, T.; Moucka, L.; Fronka, A.

    2004-01-01

    Radon transport in dwellings is governed to a significant extent by pressure differences and properties of transport pathways. A model of air flow through narrow cracks was created in order to facilitate prediction of air velocity and air flow. Theoretical calculations, based on numerical solution of a system of differential equations, were compared with measurements carried out on a window crack. (P.A.)

  13. A mathematical analysis of drug dissolution in the USP flow through apparatus

    Science.gov (United States)

    McDonnell, David; D'Arcy, D. M.; Crane, L. J.; Redmond, Brendan

    2018-03-01

    This paper applies boundary layer theory to the process of drug dissolution in the USP (United States Pharmacopeia) Flow Through Apparatus. The mass transfer rate from the vertical planar surface of a compact within the device is examined. The theoretical results obtained are then compared with those of experiment. The paper also examines the effect on the dissolution process caused by the interaction between natural and forced convection within the apparatus and the introduction of additional boundaries.

  14. Single Pass Optical Profile Monitoring

    CERN Document Server

    Jung, R; Hutchins, Stephen

    2003-01-01

    Beam profiles are acquired in transfer lines to monitor extracted beams and compute their emittance. Measurements performed on the first revolutions of a ring will evaluate the matching of a chain of accelerators. Depending on the particle type and energy, these measurements are in general performed with screens, making either use of Luminescence or Optical Transition Radiation [OTR], and the generated beam images are acquired with sensors of various types. Sometimes the beam position is also measured this way. The principle, advantages and disadvantages of both families of screens will be discussed in relation with the detectors used. Test results with beam and a possible evaluation method for luminescent screens will be presented. Finally other optical methods used will be mentioned for completeness.

  15. Klinkenberg effect in hydrodynamics of gas flow through anisotropic porous materials

    Directory of Open Access Journals (Sweden)

    Wałowski Grzegorz

    2017-01-01

    Full Text Available This study discusses results of experiments on hydrodynamic assessment of gas flow through backbone (skeletal porous materials with an anisotropic structure. The research was conducted upon materials of diversified petrographic characteristics, both natural origin (rocky, pumice and process materials (char and coke. The study was conducted for a variety of hydrodynamic conditions, using air, as well as for nitrogen and carbon dioxide. The basis for assessing hydrodynamics of gas flow through porous material was a gas stream that results from the pressure forcing such flow. The results of measurements indicate a clear impact of the type of material on the gas permeability, and additionally – as a result of their anisotropic internal structure – to a significant effect of the flow direction on the value of gas stream.

  16. Numerical computational of fluid flow through a detached retina

    Science.gov (United States)

    Jiann, Lim Yeou; Ismail, Zuhaila; Shafie, Sharidan; Fitt, Alistair

    2015-02-01

    In this paper, a phenomenon of fluid flow through a detached retina is studied. Rhegmatogeneous retinal detachment happens when vitreous humour flow through a detached retina. The exact mechanism of Rhegmatogeneous retinal detachment is complex and remains incomplete. To understand the fluid flow, a paradigm mathematical model is developed and is approximated by the lubrication theory. The numerical results of the velocity profile and pressure distribution are computed by using Finite Element Method. The effects of fluid mechanical on the retinal detachment is discussed and analyzed. Based on the analysis, it is found that the retinal detachment deformation affects the pressure distribution. It is important to comprehend the development of the retinal detachment so that a new treatment method can be developed.

  17. On Numerical Simulation of Flow Through Oil Filters

    OpenAIRE

    Iliev, O.; Laptev, V.

    2003-01-01

    This paper concerns numerical simulation of flow through oil filters. Oil filters consist of filter housing (filter box), and a porous filtering medium, which completely separates the inlet from the outlet. We discuss mathematical models, describing coupled flows in the pure liquid subregions and in the porous filter media, as well as interface conditions between them. Further, we reformulate the problem in fictitious regions method manner, and discuss peculiarities of the numerical algorithm...

  18. Spatial statistics for predicting flow through a rock fracture

    International Nuclear Information System (INIS)

    Coakley, K.J.

    1989-03-01

    Fluid flow through a single rock fracture depends on the shape of the space between the upper and lower pieces of rock which define the fracture. In this thesis, the normalized flow through a fracture, i.e. the equivalent permeability of a fracture, is predicted in terms of spatial statistics computed from the arrangement of voids, i.e. open spaces, and contact areas within the fracture. Patterns of voids and contact areas, with complexity typical of experimental data, are simulated by clipping a correlated Gaussian process defined on a N by N pixel square region. The voids have constant aperture; the distance between the upper and lower surfaces which define the fracture is either zero or a constant. Local flow is assumed to be proportional to local aperture cubed times local pressure gradient. The flow through a pattern of voids and contact areas is solved using a finite-difference method. After solving for the flow through simulated 10 by 10 by 30 pixel patterns of voids and contact areas, a model to predict equivalent permeability is developed. The first model is for patterns with 80% voids where all voids have the same aperture. The equivalent permeability of a pattern is predicted in terms of spatial statistics computed from the arrangement of voids and contact areas within the pattern. Four spatial statistics are examined. The change point statistic measures how often adjacent pixel alternate from void to contact area (or vice versa ) in the rows of the patterns which are parallel to the overall flow direction. 37 refs., 66 figs., 41 tabs

  19. SPH numerical simulation of fluid flow through a porous media

    Science.gov (United States)

    Klapp-Escribano, Jaime; Mayoral-Villa, Estela; Rodriguez-Meza, Mario Alberto; de La Cruz-Sanchez, Eduardo; di G Sigalotti, Leonardo; Inin-Abacus Collaboration; Ivic Collaboration

    2013-11-01

    We have tested an improved a method for 3D SPH simulations of fluid flow through a porous media using an implementation of this method with the Dual-Physics code. This improvement makes it possible to simulate many particles (of the order of several million) in reasonable computer times because its execution on GPUs processors makes it possible to reduce considerably the simulation cost for large systems. Modifications in the initial configuration have been implemented in order to simulate different arrays and geometries for the porous media. The basic tests were reproduced and the performance was analyzed. Our 3D simulations of fluid flow through a saturated homogeneous porous media shows a discharge velocity proportional to the hydraulic gradient reproducing Darcy's law at small body forces. The results are comparable with values obtained in previous work and published in the literature for simulations of flow through periodic porous media. Our simulations for a non saturated porous media produce adequate qualitative results showing that a non steady state is generated. The relaxation time for these systems were obtained. Work partially supported by Cinvestav-ABACUS, CONACyT grant EDOMEX-2011-C01-165873.

  20. Absorption characteristic of paeoniflorin-6'-O-benzene sulfonate (CP-25) in in situ single-pass intestinal perfusion in rats.

    Science.gov (United States)

    Yang, Xiao-Dan; Wang, Chun; Zhou, Peng; Yu, Jun; Asenso, James; Ma, Yong; Wei, Wei

    2016-09-01

    1. Paeoniflorin-6'-O-benzene sulfonate (CP-25) was synthesized to improve the poor oral absorption of paeoniflorin (Pae). 2. This study was performed to investigate the absorptive behavior and mechanism of CP-25 in in situ single-pass intestinal perfusion in rats, using Pae as a control. 3. The results showed that intestinal absorption of CP-25 was neither segmental nor sex dependent. However, the main segment of intestine that absorbed Pae was the duodenum. Furthermore, passive transport was confirmed to be the main absorption pattern of CP-25. More importantly, the absorption of CP-25 was much higher than Pae in the small intestine. 4. Among the ABC transporter inhibitors, the absorption rate of Pae increased in the presence of P-gp inhibitors verapamil and GF120918, which indicated that Pae was a substrate of P-glycoprotein (P-gp), however, such was not observed in the presence of breast cancer resistance protein and multidrug resistance-associated protein 2. Finally, the ABC transporter inhibitors did not have any significant impact on CP-25 as demonstrated in the parallel studies. 5. CP-25 could improve the poor absorption of Pae, which may be attributed to both the lipid solubility enhancement and its resistance to P-gp-mediated efflux.

  1. Double Pass 595 nm Pulsed Dye Laser Does Not Enhance the Efficacy of Port Wine Stains Compared with Single Pass: A Randomized Comparison with Histological Examination.

    Science.gov (United States)

    Yu, Wenxin; Zhu, Jiafang; Wang, Lizhen; Qiu, Yajing; Chen, Yijie; Yang, Xi; Chang, Lei; Ma, Gang; Lin, Xiaoxi

    2018-03-27

    To compare the efficacy and safety of double-pass pulsed dye laser (DWL) and single-pass PDL (SWL) in treating virgin port wine stain (PWS). The increase in the extent of vascular damage attributed to the use of double-pass techniques for PWS remains inconclusive. A prospective, side-by-side comparison with a histological study for virgin PWS is still lacking. Twenty-one patients (11 flat PWS, 10 hypertrophic PWS) with untreated PWS underwent 3 treatments at 2-month intervals. Each PWS was divided into three treatment sites: SWL, DWL, and untreated control. Chromametric and visual evaluation of the efficacy and evaluation of side effects were conducted 3 months after final treatment. Biopsies were taken at the treated sites immediately posttreatment. Chromametric and visual evaluation suggested that DWL sites showed no significant improvement compared with SWL (p > 0.05) in treating PWS. The mean depth of photothermal damage to the vessels was limited to a maximum of 0.36-0.41 mm in both SWL and DWL sides. Permanent side effects were not observed in any patients. Double-pass PDL does not enhance PWS clearance. To improve the clearance of PWS lesions, either the depth of laser penetration should be increased or greater photothermal damage to vessels should be generated.

  2. High-resolution digital elevation models from single-pass TanDEM-X interferometry over mountainous regions: A case study of Inylchek Glacier, Central Asia

    Science.gov (United States)

    Neelmeijer, Julia; Motagh, Mahdi; Bookhagen, Bodo

    2017-08-01

    This study demonstrates the potential of using single-pass TanDEM-X (TDX) radar imagery to analyse inter- and intra-annual glacier changes in mountainous terrain. Based on SAR images acquired in February 2012, March 2013 and November 2013 over the Inylchek Glacier, Kyrgyzstan, we discuss in detail the processing steps required to generate three reliable digital elevation models (DEMs) with a spatial resolution of 10 m that can be used for glacial mass balance studies. We describe the interferometric processing steps and the influence of a priori elevation information that is required to model long-wavelength topographic effects. We also focus on DEM alignment to allow optimal DEM comparisons and on the effects of radar signal penetration on ice and snow surface elevations. We finally compare glacier elevation changes between the three TDX DEMs and the C-band shuttle radar topography mission (SRTM) DEM from February 2000. We introduce a new approach for glacier elevation change calculations that depends on the elevation and slope of the terrain. We highlight the superior quality of the TDX DEMs compared to the SRTM DEM, describe remaining DEM uncertainties and discuss the limitations that arise due to the side-looking nature of the radar sensor.

  3. Segmental-dependent membrane permeability along the intestine following oral drug administration: Evaluation of a triple single-pass intestinal perfusion (TSPIP) approach in the rat.

    Science.gov (United States)

    Dahan, Arik; West, Brady T; Amidon, Gordon L

    2009-02-15

    In this paper we evaluate a modified approach to the traditional single-pass intestinal perfusion (SPIP) rat model in investigating segmental-dependent permeability along the intestine following oral drug administration. Whereas in the traditional model one single segment of the intestine is perfused, we have simultaneously perfused three individual segments of each rat intestine: proximal jejunum, mid-small intestine and distal ileum, enabling to obtain tripled data from each rat compared to the traditional model. Three drugs, with different permeabilities, were utilized to evaluate the model: metoprolol, propranolol and cimetidine. Data was evaluated in comparison to the traditional method. Metoprolol and propranolol showed similar P(eff) values in the modified model in all segments. Segmental-dependent permeability was obtained for cimetidine, with lower P(eff) in the distal parts. Similar P(eff) values for all drugs were obtained in the traditional method, illustrating that the modified model is as accurate as the traditional, throughout a wide range of permeability characteristics, whether the permeability is constant or segment-dependent along the intestine. Three-fold higher statistical power to detect segmental-dependency was obtained in the modified approach, as each subject serves as his own control. In conclusion, the Triple SPIP model can reduce the number of animals utilized in segmental-dependent permeability research without compromising the quality of the data obtained.

  4. Entropy Generation in Laminar Fluid Flow through a Circular Pipe

    Directory of Open Access Journals (Sweden)

    Rached Ben-Mansour

    2003-12-01

    Full Text Available Abstract: A numerical solution to the entropy generation in a circular pipe is made. Radial and axial variations are considered. Navier-Stokes equations in cylindrical coordinates are used to solve the velocity and temperature fields. Uniform wall heat flux is considered as the thermal boundary condition. The distribution of the entropy generation rate is investigated throughout the volume of the fluid as it flows through the pipe. Engine oil is selected as the working fluid. In addition, water and Freon are used in a parametric study. The total entropy generation rate is calculated by integration over the various cross-sections as well as over the entire volume.

  5. Compressible fluid flow through rocks of variable permeability

    International Nuclear Information System (INIS)

    Lin, W.

    1977-01-01

    The effectiveness of course-grained igneous rocks as shelters for burying radioactive waste can be assessed by determining the rock permeabilities at their in situ pressures and stresses. Analytical and numerical methods were used to solve differential equations of one-dimensional fluid flow through rocks with permeabilities from 10 4 to 1 nD. In these calculations, upstream and downstream reservoir volumes of 5, 50, and 500 cm 3 were used. The optimal size combinations of the two reservoirs were determined for measurements of permeability, stress, strain, acoustic velocity, and electrical conductivity on low-porosity, coarse-grained igneous rocks

  6. Characterization of frictional pressure drop for liquid flows through microchannels

    Energy Technology Data Exchange (ETDEWEB)

    Judy, J.; Maynes, D.; Webb, B.W. [Brigham Young University, Provo, UT (United States). Department of Mechanical Engineering

    2002-08-01

    This paper investigates pressure driven liquid flow through round and square microchannels fabricated from fused silica and stainless steel. Pressure drop data are used to characterize the friction factor for channel diameters in the range 15-150{mu}m and over a Reynolds number range 8-2300. Distilled water, methanol, and isopropanol were used in this study based on their distinct polarity and viscosity properties. Distinguishable deviation from Stokes flow theory was not observed for any channel cross-section, diameter, material, or fluid explored. (author)

  7. The use of air flow through water for water evaporation

    International Nuclear Information System (INIS)

    Lashin, A.A.

    1996-01-01

    In water desalination system the productivity rate is improved by increasing the rate of eater evaporation either by heating the water or by forcing air to carry more vapor before condensation. This paper describe an experimental investigation into the effect of forcing the air to flow through a hot water contained in a closed tank through a perforated end of inlet tube. When the air bubbles pass through the water, it increases the rate of vaporization. The effect of some operating parameters are investigated and the results are presented and discussed. 6 figs

  8. CARBON AND NUTRIENT FLOW THROUGH MULTIPLE TROPHIC LEVELS IN A CO2-ENRICHED SOUTHERN PINE FOREST COMMUNITY - FINAL TECHNICAL REPORT

    Science.gov (United States)

    The ability to predict the consequences of global change is predicated on our understanding of controls of energy and material flows through ecosystems. Research was conducted at the Forest Atmosphere CO2 Transfer and Storage-1 (FACTS-1) site at Duke University. This is a flagship experiment of the ...

  9. A parametric model of radioisotopic tracer flow through the kidney

    International Nuclear Information System (INIS)

    Nahorski, Z.

    1996-01-01

    To assess the state of a kidney from radiological examination a dynamic model of flow of an isotopic tracer through the kidney, of a convolution type, is commonly used. It is a nonparametric model where the output is related to the input by an integral relation. In this paper a new parametric model of tracer flow through the kidney is presented. It takes to much bigger extent into account the physiology of the tracer flow in kidney than previously proposed compartmental models. It consists of the submodels of flow through nephrons which are in the form of ordinary differential equations with pure delays between input and the output flows. The delay is caused by the time of passage of the isotope through nephrons and depends on the nephron length. It is assumed that the distribution of nephrons of different length is exponential. The renal pelvis is described as the one-compartment model. The solutions of the equations are given for the assumed two-exponential decay of the isotope tracer in the blood following the bolus injection of the tracer. The formulae obtained are then used to simulate the influence of changes in the model parameters, representing the flow condition through the kidney, on the shape of the waveforms depicting time evolution of the amount of the isotope being in the kidney

  10. Closed-Loop Doluisio (Colon, Small Intestine) and Single-Pass Intestinal Perfusion (Colon, Jejunum) in Rat-Biophysical Model and Predictions Based on Caco-2.

    Science.gov (United States)

    Lozoya-Agullo, Isabel; Gonzalez-Alvarez, Isabel; Zur, Moran; Fine-Shamir, Noa; Cohen, Yael; Markovic, Milica; Garrigues, Teresa M; Dahan, Arik; Gonzalez-Alvarez, Marta; Merino-Sanjuán, Matilde; Bermejo, Marival; Avdeef, Alex

    2017-12-29

    The effective rat intestinal permeability (P eff ) was deconvolved using a biophysical model based on parameterized paracellular, aqueous boundary layer, transcellular permeabilities, and the villus-fold surface area expansion factor. Four types of rat intestinal perfusion data were considered: single-pass intestinal perfusion (SPIP) in the jejunum (n = 40), and colon (n = 15), closed-loop (Doluisio type) in the small intestine (n = 78), and colon (n = 74). Moreover, in vitro Caco-2 permeability values were used to predict rat in vivo values in the rat data studied. Comparable number of molecules permeate via paracellular water channels as by the lipoidal transcellular route in the SPIP method, although in the closed-loop method, the paracellular route appears dominant in the colon. The aqueous boundary layer thickness in the small intestine is comparable to that found in unstirred in vitro monolayer assays; it is thinner in the colon. The mucosal surface area in anaesthetized rats is 0.96-1.4 times the smooth cylinder calculated value in the colon, and it is 3.1-3.6 times in the small intestine. The paracellular permeability of the intestine appeared to be greater in rat than human, with the colon showing more leakiness (higher P para ) than the small intestine. Based on log intrinsic permeability values, the correlations between the in vitro and in vivo models ranged from r 2 0.82 to 0.92. The SPIP-Doluisio method comparison indicated identical log permeability selectivity trend with negligible bias.

  11. Steel slag carbonation in a flow-through reactor system: the role of fluid-flux.

    Science.gov (United States)

    Berryman, Eleanor J; Williams-Jones, Anthony E; Migdisov, Artashes A

    2015-01-01

    Steel production is currently the largest industrial source of atmospheric CO2. As annual steel production continues to grow, the need for effective methods of reducing its carbon footprint increases correspondingly. The carbonation of the calcium-bearing phases in steel slag generated during basic oxygen furnace (BOF) steel production, in particular its major constituent, larnite {Ca2SiO4}, which is a structural analogue of olivine {(MgFe)2SiO4}, the main mineral subjected to natural carbonation in peridotites, offers the potential to offset some of these emissions. However, the controls on the nature and efficiency of steel slag carbonation are yet to be completely understood. Experiments were conducted exposing steel slag grains to a CO2-H2O mixture in both batch and flow-through reactors to investigate the impact of temperature, fluid flux, and reaction gradient on the dissolution and carbonation of steel slag. The results of these experiments show that dissolution and carbonation of BOF steel slag are more efficient in a flow-through reactor than in the batch reactors used in most previous studies. Moreover, they show that fluid flux needs to be optimized in addition to grain size, pressure, and temperature, in order to maximize the efficiency of carbonation. Based on these results, a two-stage reactor consisting of a high and a low fluid-flux chamber is proposed for CO2 sequestration by steel slag carbonation, allowing dissolution of the slag and precipitation of calcium carbonate to occur within a single flow-through system. Copyright © 2014. Published by Elsevier B.V.

  12. Bounds on fluid permeability for viscous flow through porous media

    International Nuclear Information System (INIS)

    Berryman, J.G.

    1985-01-01

    General properties of variational bounds on Darcy's constant for slow viscous flow through porous media are studied. The bounds are also evaluated numerically for the penetrable sphere model. The bound of Doi depending on two-point correlations and the analytical bound of Weissberg and Prager give comparable results in the low density limit but the analytical bound is superior for higher densities. Prager's bound depending on three-point correlation functions is worse than the analytical bound at low densities but better (although comparable to it) at high densities. A procedure for methodically improving Prager's three point bound is presented. By introducing a Gaussian trial function, the three-point bound is improved by an order of magnitude for moderate values of porosity. The new bounds are comparable in magnitude to the Kozeny--Carman empirical relation for porous materials

  13. Flow-through biological conversion of lignocellulosic biomass

    Science.gov (United States)

    Herring, Christopher D.; Liu, Chaogang; Bardsley, John

    2014-07-01

    The present invention is directed to a process for biologically converting carbohydrates from lignocellulosic biomass comprising the steps of: suspending lignocellulosic biomass in a flow-through reactor, passing a reaction solution into the reactor, wherein the solution is absorbed into the biomass substrate and at least a portion of the solution migrates through said biomass substrate to a liquid reservoir, recirculating the reaction solution in the liquid reservoir at least once to be absorbed into and migrate through the biomass substrate again. The biological converting of the may involve hydrolyzing cellulose, hemicellulose, or a combination thereof to form oligosaccharides, monomelic sugars, or a combination thereof; fermenting oligosaccharides, monomelic sugars, or a combination thereof to produce ethanol, or a combination thereof. The process can further comprise removing the reaction solution and processing the solution to separate the ethanol produced from non-fermented solids.

  14. Simulation of blood flow through an artificial heart

    Science.gov (United States)

    Kiris, Cetin; Chang, I-Dee; Rogers, Stuart E.; Kwak, Dochan

    1991-01-01

    A numerical simulation of the incompressible viscous flow through a prosthetic tilting disk heart valve is presented in order to demonstrate the current capability to model unsteady flows with moving boundaries. Both steady state and unsteady flow calculations are done by solving the incompressible Navier-Stokes equations in 3-D generalized curvilinear coordinates. In order to handle the moving boundary problems, the chimera grid embedding scheme which decomposes a complex computational domain into several simple subdomains is used. An algebraic turbulence model for internal flows is incorporated to reach the physiological values of Reynolds number. Good agreement is obtained between the numerical results and experimental measurements. It is found that the tilting disk valve causes large regions of separated flow, and regions of high shear.

  15. Turbulent flow through a wall subchannel of a rod bundle

    International Nuclear Information System (INIS)

    Rehme, K.

    1978-04-01

    The turbulent flow through a wall subchannel of a rod bundle was investigated experimentally by means of hotwires und Pitot-tubes. The aim of this investigation was to get experimental information on the transport properties of turbulent flow especially on the momentum transport. Detailed data were measured of the distributions of the time-mean velocity, the turbulence intensities and, hence the kinetic of turbulence, of the shear stresses in the directions normal and parallel to the walls, and of the wall shear stresses. The pitch-to-diameter ratio of the rods equal to the wall-to-diameter ratio was 1.15, the Reynolds number of this investigation was Re = 1.23.10 5 . On the basis of the measurements the eddy viscosities normal and parallel to the walls were calculated. The eddy viscosities observed showed a considerable deviation from the data known up-to-now and from the assumptions introduced in the codes. (orig.) [de

  16. Numerical simulation of steady and unsteady flows through plane cascades

    Science.gov (United States)

    Fořt, J.; Huněk, M.; Kozel, K.; Lain, J.; Šejna, M.; Vavřincová, M.

    This paper of a few co-authors presents some works of the group of the Department of Technical Mathematics, Faculty of Mechanical Eng., TU Prague, which deals with numerical methods in fluid dynamics. We present numerical methods for a solution of different physical and mathematical models of flow through plane cascades. We use the Mac Cormack's scheme, Ron — Ho — Ni's scheme and Runge — Kutta schemes on H — type structured grid and upwind schemes on an unstructured triangular grid. This methods are used for simulation of steady or unsteady inviscid flow and for simulation of viscous laminar flow. We deal with comparison of different methods mutually and with experimental data and with comparison of different physical and mathematical models of flow used for numerical simulation.

  17. Resistance coefficient during ice slurry flow through pipe sudden constriction

    Directory of Open Access Journals (Sweden)

    Ł. Mika

    2010-07-01

    Full Text Available Due to the adverse environmental effects of some commonly-used refrigerants, efforts are still underway to find new cooling mediumsthat would be safer to the ozone layer and would not increase the greenhouse effect. Ice slurry as a new ecological coolant suits theprocesses requiring the preservation of constant and equal temperature in the cooling process of the full section of the cooled solid. Thanks to that, ice slurry can find a wide potential application in such branches of industry, as heat treatment, materials engineering, or foundry. In this paper, flow systems which are commonly used in fittings elements such as diameter’s reductions in ice slurry pipelines, are experimentally investigated. In the study reported in this paper, the consideration was given to the specific features of the slurry flow in which the flow qualities depend mainly on the volume fraction of solid particles. The results of the experimental studies on the flow resistance, presented herein, enabled to determine the resistance coefficient during the ice slurry flow through the pipe sudden constriction. The volume fraction of solid particles in the slurry ranged from 5 to 30%. The recommended and non-recommended range of the Reynolds number for the ice slurry flow through the pipe sudden constriction were presented in this paper. The experimental studies were conducted on a few variants of the most common reductions of copper pipes. Further studies on the determination of the resistance coefficient in the remaining fittings elements of the pipeline were recommended in the paper as well as the further theoretical studies intended to determine the theoretical relations to calculate the resistance coefficient in all the fittings elements in the pipeline (on the basis of the experimental studies and to elaborate the calculation pattern of the entire ice slurry system.

  18. FEWA: a Finite Element model of Water flow through Aquifers

    International Nuclear Information System (INIS)

    Yeh, G.T.; Huff, D.D.

    1983-11-01

    This report documents the implementation and demonstration of a Finite Element model of Water flow through Aquifers (FEWA). The particular features of FEWA are its versatility and flexibility to deal with as many real-world problems as possible. Point as well as distributed sources/sinks are included to represent recharges/pumpings and rainfall infiltrations. All sources/sinks can be transient or steady state. Prescribed hydraulic head on the Dirichlet boundaries and fluxes on Neumann or Cauchy boundaries can be time-dependent or constant. Source/sink strength over each element and node, hydraulic head at each Dirichlet boundary node, and flux at each boundary segment can vary independently of each other. Either completely confined or completely unconfined aquifers, or partially confined and partially unconfined aquifers can be dealt with effectively. Discretization of a compound region with very irregular curved boundaries is made easy by including both quadrilateral and triangular elements in the formulation. Large-field problems can be solved efficiently by including a pointwise iterative solution strategy as an optional alternative to the direct elimination solution method for the matrix equation approximating the partial differential equation of groundwater flow. FEWA also includes transient flow through confining leaky aquifers lying above and/or below the aquifer of interest. The model is verified against three simple cases to which analytical solutions are available. It is then demonstrated by two examples of how the model can be applied to heterogeneous and anisotropic aquifers with transient boundary conditions, time-dependent sources/sinks, and confining aquitards for a confined aquifer of variable thickness and for a free surface problem in an unconfined aquifer, respectively. 20 references, 25 figures, 8 tables

  19. Experimental study and DEM simulation of granular flow through a new sphere discharge valve

    International Nuclear Information System (INIS)

    Zhang He; Li Tianjin; Huang Zhiyong; Gao Zhi; Qi Weiwei; Bo Hanliang

    2015-01-01

    Experiments and DEM simulation have been conducted to investigate the granular flow through a new type of sphere discharge valve. The new sphere discharge valve was based on the principle of angle of repose. The glass sphere was used in the granular discharge experiments. Experimental results showed that the relation between the averaging sphere discharge mass flow rate and the stroke of the sphere discharge valve were consisted of three zones, i.e. the idle stroke zone, linearly zone and orifice restriction zone. The Beverloo's law was suitable for the granular flow through multi-orifices in the orifice restriction zone. The variation of averaging sphere discharge mass flow rate with the stroke of the sphere discharge valve was described by Beverloo's law with the modification based on the stroke of the sphere discharge valve. DEM simulation results showed that the drained angle of repose during granular flow in the sphere storage vessel remained 23 degrees with different stroke of the sphere discharge valve. (authors)

  20. Integral Transport Analysis Results for Ions Flowing Through Neutral Gas

    Science.gov (United States)

    Emmert, Gilbert; Santarius, John

    2017-10-01

    Results of a computational model for the flow of energetic ions and neutrals through a background neutral gas will be presented. The method models reactions as creating a new source of ions or neutrals if the energy or charge state of the resulting particle is changed. For a given source boundary condition, the creation and annihilation of the various species is formulated as a 1-D Volterra integral equation that can quickly be solved numerically by finite differences. The present work focuses on multiple-pass, 1-D ion flow through neutral gas and a nearly transparent, concentric anode and cathode pair in spherical, cylindrical, or linear geometry. This has been implemented as a computer code for atomic (3He, 3He +, 3He + +) and molecular (D, D2, D-, D +, D2 +, D3 +) ion and neutral species, and applied to modeling inertial-electrostatic connement (IEC) devices. The code yields detailed energy spectra of the various ions and energetic neutral species. Calculations for several University of Wisconsin IEC and ion implantation devices will be presented. Research supported by US Dept. of Homeland Security Grant 2015-DN-077-ARI095, Dept. of Energy Grant DE-FG02-04ER54745, and the Grainger Foundation.

  1. Magnetohydraulic flow through a packed bed of electrically conducting spheres

    International Nuclear Information System (INIS)

    Sanders, T.L.

    1985-01-01

    The flow of an electrically conducting fluid through a packed bed of electrically conducting spheres in the presence of a strong magnetic field constitutes a very complex flow situation due to the constant turning of the fluid in and out of magnetic field lines. The interaction of the orthogonal components of the velocity and magnetic field will induce electric fields that are orthogonal to both and the electric fields in turn can cause currents that interact with the magnetic field to generate forces against the direction of flow. The strengths of these generated forces depend primarily upon the closure paths taken by the induced currents which, in turn, depend upon the relative ratio of the electrical resistance of the solid spheres to that of the fluid. Both experimental and analytical analyses of the slow flow of a eutectic mixture of sodium and potassium (NaK) through packed cylinders containing stainless steel spheres in the presence of a strong transverse magnetic field were completed. A theory of magnetohydraulic flow is developed by analogy with the development of hydraulic radius theories of flow through porous media. An exact regional analysis is successfully applied to an infinite bed of electrically conducting spheres with a conducting or non-conducting constraining wall on one side. The equations derived are solved for many different combinations of flowrate, magnetic field strength, porosity, and electrical resistance ratio

  2. A 3D velocimetry study of the flow through prosthetic heart valves

    Science.gov (United States)

    Ledesma, R.; Zenit, R.; Pulos, G.; Sanchez, E.; Juarez, A.

    2006-11-01

    Blood damage commonly appears in medical valve prothesis. It is a mayor concern for the designers and surgeons. It is well known that this damage and other complications result from the modified fluid dynamics through the replacement valve. To evaluate the performance of prosthetic heart valves, it is necessary to study the flow through them. To conduct this study , we have built a flow channel that emulates cardiac conditions and allows optical access such that a 3D-PIV velocimetry system could be used. The experiments are aimed to reconstruct the downstream structure of the flow through a mechanical and a bio-material tricuspid heart valve prothesis. Preliminary results show that the observed coherent structures can be related with haemolysis and trombosis, illnesses commonly found in valve prothesis recipients. The mean flow, the levels of strain rate and the turbulence intensity generated by the valves can also be directly related to blood damage. In general, bio-material made valves tend to reduce these complications.

  3. Numerical simulation of water flow through the bottom end piece of a nuclear fuel assembly

    International Nuclear Information System (INIS)

    Navarro, Moyses Alberto; Santos, Andre A.C. dos

    2007-01-01

    An experimental and numerical study was conducted on the pressure loss of flows through the bottom end piece of a nuclear fuel assembly. To determine an optimized numerical methodology using the commercial CFD code, CFX 10.0, a series of preliminary simulations of water flows through perforated plates in a square ducts were performed. A perforated plate is a predominant geometry of the bottom end piece, responsible for the majority of the flow's pressure drop. The numerical pressure loss applying an optimized mesh and the k-ε turbulence model showed good agreement when compared with a conventional methodology (Idelchik). Numerical results for the standard bottom end piece were obtained applying the previously determined mesh criteria and the k-ε turbulence model with some geometric simplifications. The agreement between the numerical simulations and experimental results can be considered satisfactory but suggest further numerical investigations with the bottom piece under real conditions of the experiment, without the geometric simplifications and with a gap between the piece and the wall of the flow channel. Additionally, other turbulence models should be appraised for this complex geometry. (author)

  4. Numerical Simulation of Water Flow through the Bottom End Piece of a Nuclear Fuel Assembly

    Science.gov (United States)

    Navarro, Moysés A.; Santos, André A. C. Dos

    An experimental and numerical study was conducted on the pressure loss of flows through the bottom end piece of a nuclear fuel assembly. To determine an optimized numerical methodology using the commercial CFD code, CFX 10.0, a series of preliminary simulations of water flows through perforated plates in a square ducts were performed. A perforated plate is a predominant geometry of the bottom end piece, responsible for the majority of the flow's pressure drop. The numerical pressure loss applying an optimized mesh and the k-ɛ turbulence model showed good agreement when compared with a conventional methodology (Idelchik). Numerical results for the standard bottom end piece were obtained applying the previously determined mesh criteria and the k-ɛ turbulence model with some geometric simplifications. The agreement between the numerical simulations and experimental results can be considered satisfactory but suggests further numerical investigations with the bottom piece under real conditions of the experiment, without the geometric simplifications and with a gap between the piece and the wall of the flow channel. Additionally, other turbulence models should be appraised for this complex geometry.

  5. Chemical Gardens as Flow-through Reactors Simulating Natural Hydrothermal Systems.

    Science.gov (United States)

    Barge, Laura M; Abedian, Yeghegis; Doloboff, Ivria J; Nuñez, Jessica E; Russell, Michael J; Kidd, Richard D; Kanik, Isik

    2015-11-18

    Here we report experimental simulations of hydrothermal chimney growth using injection chemical garden methods. The versatility of this type of experiment allows for testing of various proposed ocean / hydrothermal fluid chemistries that could have driven reactions toward the origin of life in environments on the early Earth, early Mars, or even other worlds such as the icy moons of the outer planets. We show experiments that include growth of chemical garden structures under anoxic conditions simulating the early Earth, inclusion of trace components of phosphates / organics in the injection solution to incorporate them into the structure, a switch of the injection solution to introduce a secondary precipitating anion, and the measurement of membrane potentials generated by chemical gardens. Using this method, self-assembling chemical garden structures were formed that mimic the natural chimneys precipitated at submarine hydrothermal springs, and these precipitates can be used successfully as flow-through reactors by feeding through multiple successive "hydrothermal" injections.

  6. Helium-air exchange flows through partitioned opening and two-opening

    International Nuclear Information System (INIS)

    Kang, T. I.

    1997-01-01

    This paper describes experimental investigations of helium-air exchange flows through partitioned opening and two-opening. Such exchange flows may occur following rupture accident of stand pipe in high temperature engineering test reactor. A test vessel with the two types of small opening on top of test cylinder is used for experiments. An estimation method of mass increment is developed to measure the exchange flow rate. Upward flow of the helium and downward flow of the air in partitioned opening system interact out of entrance and exit of the opening. Therefore, an experiment with two-opening system is made to investigate effect of the fluids interaction of partitioned opening system. As a result of comparison of the exchange flow rates between two types of the opening system, it is demonstrated that the exchange flow rate of the two-opening system is larger than that of the partitioned opening system because of absence of the effect of fluids interaction. (author)

  7. Current challenges in quantifying preferential flow through the vadose zone

    Science.gov (United States)

    Koestel, John; Larsbo, Mats; Jarvis, Nick

    2017-04-01

    In this presentation, we give an overview of current challenges in quantifying preferential flow through the vadose zone. A review of the literature suggests that current generation models do not fully reflect the present state of process understanding and empirical knowledge of preferential flow. We believe that the development of improved models will be stimulated by the increasingly widespread application of novel imaging technologies as well as future advances in computational power and numerical techniques. One of the main challenges in this respect is to bridge the large gap between the scales at which preferential flow occurs (pore to Darcy scales) and the scale of interest for management (fields, catchments, regions). Studies at the pore scale are being supported by the development of 3-D non-invasive imaging and numerical simulation techniques. These studies are leading to a better understanding of how macropore network topology and initial/boundary conditions control key state variables like matric potential and thus the strength of preferential flow. Extrapolation of this knowledge to larger scales would require support from theoretical frameworks such as key concepts from percolation and network theory, since we lack measurement technologies to quantify macropore networks at these large scales. Linked hydro-geophysical measurement techniques that produce highly spatially and temporally resolved data enable investigation of the larger-scale heterogeneities that can generate preferential flow patterns at pedon, hillslope and field scales. At larger regional and global scales, improved methods of data-mining and analyses of large datasets (machine learning) may help in parameterizing models as well as lead to new insights into the relationships between soil susceptibility to preferential flow and site attributes (climate, land uses, soil types).

  8. Computing variational bounds for flow through random aggregates of Spheres

    International Nuclear Information System (INIS)

    Berryman, J.G.

    1983-01-01

    Known formulas for variational bounds on Darcy's constant for slow flow through porous media depend on two-point and three-poiint spatial correlation functions. Certain bounds due to Prager and Doi depending only a two-point correlation functions have been calculated for the first time for random aggregates of spheres with packing fractions (eta) up to eta = 0.64. Three radial distribution functions for hard spheres were tested for eta up to 0.49: (1) the uniform distribution or ''well-stirred approximation,'' (2) the Percus Yevick approximation, and (3) the semi-empirical distribution of Verlet and Weis. The empirical radial distribution functions of Benett andd Finney were used for packing fractions near the random-close-packing limit (eta/sub RCP/dapprox.0.64). An accurate multidimensional Monte Carlo integration method (VEGAS) developed by Lepage was used to compute the required two-point correlation functions. The results show that Doi's bounds are preferred for eta>0.10 while Prager's bounds are preferred for eta>0.10. The ''upper bounds'' computed using the well-stirred approximation actually become negative (which is physically impossible) as eta increases, indicating the very limited value of this approximation. The other two choices of radial distribution function give reasonable results for eta up to 0.49. However, these bounds do not decrease with eta as fast as expected for large eta. It is concluded that variational bounds dependent on three-point correlation functions are required to obtain more accurate bounds on Darcy's constant for large eta

  9. Modeling of Unsteady Flow through the Canals by Semiexact Method

    Directory of Open Access Journals (Sweden)

    Farshad Ehsani

    2014-01-01

    Full Text Available The study of free-surface and pressurized water flows in channels has many interesting application, one of the most important being the modeling of the phenomena in the area of natural water systems (rivers, estuaries as well as in that of man-made systems (canals, pipes. For the development of major river engineering projects, such as flood prevention and flood control, there is an essential need to have an instrument that be able to model and predict the consequences of any possible phenomenon on the environment and in particular the new hydraulic characteristics of the system. The basic equations expressing hydraulic principles were formulated in the 19th century by Barre de Saint Venant and Valentin Joseph Boussinesq. The original hydraulic model of the Saint Venant equations is written in the form of a system of two partial differential equations and it is derived under the assumption that the flow is one-dimensional, the cross-sectional velocity is uniform, the streamline curvature is small and the pressure distribution is hydrostatic. The St. Venant equations must be solved with continuity equation at the same time. Until now no analytical solution for Saint Venant equations is presented. In this paper the Saint Venant equations and continuity equation are solved with homotopy perturbation method (HPM and comparison by explicit forward finite difference method (FDM. For decreasing the present error between HPM and FDM, the st.venant equations and continuity equation are solved by HAM. The homotopy analysis method (HAM contains the auxiliary parameter ħ that allows us to adjust and control the convergence region of solution series. The study has highlighted the efficiency and capability of HAM in solving Saint Venant equations and modeling of unsteady flow through the rectangular canal that is the goal of this paper and other kinds of canals.

  10. Chevron Texaco wants Kazakh oil to flow through Slovakia

    International Nuclear Information System (INIS)

    Janoska, J.

    2004-01-01

    Chevron Texaco is offering Slovakia an option for the diversification of its oil stocks. It plans to use the Druzba pipeline to transport about 3 million tons of Kazakhstan oil. Most of it should be delivered to the refinery in Czech Kralupy. Pipeline administrator, the company Transpetrol, rejects the proposal and argues that adjusting the pipeline designed for heavy Russian oil to allow the transmission of light oil would cost over SKK 2 billion (Eur 50.04 million). Transpetrol is managed by Russian concern Yukos. Russian oil companies view Caspian oil as competition and the reaction of Transpetrol only follows in line with this attitude. It may sound paradoxical, but letting Caspian oil flow through the Transpetrol pipelines would help Russian concerns expand to Western European markets. The refinery in Kralupy is connected to the IKL pipeline, which connects the Czech Republic to the German network close to the German refinery in Ingolstadt. The one-way pipeline that the Czech used to decrease their dependency on Russian oil and the Druzba pipeline in the nineties would remain unused and discussions about an investment in a change of flow direction to allow the transport of oil to Germany would take on an entirely new dimension. The interest of Chevron may therefore indicate major changes in the European oil distribution network. If the flow direction of the IKL pipeline were to change, it would not only be possible to transport Caspian oil, but also Russian oil. What's more, both US and Western European companies have their sights set on Czech and German refineries that get their oil form the Caspian region and they are also interested in capital entry to Russian oil concerns. This scenario is likely to come true in the case of Yukos

  11. Impact of normal stress on multiphase flow through rough fractures

    Science.gov (United States)

    Alves da Silva Junior, J.; Kang, P. K.; Yang, Z.; Cueto-Felgueroso, L.; Juanes, R.

    2015-12-01

    Fluid flow and transport through geologic fractures plays a key role in several areas such as groundwater hydrology, geothermal energy, oil and gas production, CO2 sequestration and nuclear waste disposal. High-permeability zones associated with fracture corridors often serve as fast fluid conduits for both single and multiphase flow in otherwise low-permeability media. When multiphase flow occurs, the presence of one phase interferes with the flow of the other phase, resulting in complex displacement patterns through the fracture, and macroscopic descriptors (such as fracture-scale capillary pressure and relative permeability) that depend on the phase concentration of both phases. Here, we investigate the impact of normal stress on single and multiphase flow through rough-walled fractures: (1) we generate synthetic aperture fields that honor the fractal roughness structure observed in real fractures; (2) we model the effect of normal stress on the fracture aperture geometry by solving the contact problem between fracture walls; and (3) we use invasion percolation with trapping to model immiscible fluid displacement and then compute relative permeability numerically for each stress scenario. Our results indicate that normal stress increases the amount of contact area in the fracture wall, which results in an increase of the tortuosity of the available path for fluid displacement. Increasing normal stress results in low relative permeability for the wetting phase due to a decrease of the available path for fluid flow, and therefore a small amount of non-wetting fluid has a large impact on the flow of the wetting fluid. We find that the relative permeability of the non-wetting fluid shows less variation with stress than the wetting fluid, and that both fluids exhibit strong phase interference at intermediate saturations. Finally, we show early results from our experimental work currently underway to validate the modeling results.

  12. Mercury flow through an Asian rice-based food web.

    Science.gov (United States)

    Abeysinghe, Kasun S; Qiu, Guangle; Goodale, Eben; Anderson, Christopher W N; Bishop, Kevin; Evers, David C; Goodale, Morgan W; Hintelmann, Holger; Liu, Shengjie; Mammides, Christos; Quan, Rui-Chang; Wang, Jin; Wu, Pianpian; Xu, Xiao-Hang; Yang, Xiao-Dong; Feng, Xinbin

    2017-10-01

    Mercury (Hg) is a globally-distributed pollutant, toxic to humans and animals. Emissions are particularly high in Asia, and the source of exposure for humans there may also be different from other regions, including rice as well as fish consumption, particularly in contaminated areas. Yet the threats Asian wildlife face in rice-based ecosystems are as yet unclear. We sought to understand how Hg flows through rice-based food webs in historic mining and non-mining regions of Guizhou, China. We measured total Hg (THg) and methylmercury (MeHg) in soil, rice, 38 animal species (27 for MeHg) spanning multiple trophic levels, and examined the relationship between stable isotopes and Hg concentrations. Our results confirm biomagnification of THg/MeHg, with a high trophic magnification slope. Invertivorous songbirds had concentrations of THg in their feathers that were 15x and 3x the concentration reported to significantly impair reproduction, at mining and non-mining sites, respectively. High concentrations in specialist rice consumers and in granivorous birds, the later as high as in piscivorous birds, suggest rice is a primary source of exposure. Spiders had the highest THg concentrations among invertebrates and may represent a vector through which Hg is passed to vertebrates, especially songbirds. Our findings suggest there could be significant population level health effects and consequent biodiversity loss in sensitive ecosystems, like agricultural wetlands, across Asia, and invertivorous songbirds would be good subjects for further studies investigating this possibility. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. An experimental flow-through assessment of acidic Fe/Mg smectite formation on early Mars

    Science.gov (United States)

    Sutter, B.; Peretyazhko, T.; Garcia, A. H.; Ming, D. W.

    2017-12-01

    Orbital observations have detected the phyllosilicate smectite in layered material hundreds of meters thick, intracrater depositional fans, and plains sediments on Mars; however, the detection of carbonate deposits is limited. Instead of neutral/alkaline conditions during the Noachian, early Mars may have experienced mildly acidic conditions derived from volcanic acid-sulfate solutions that allowed Fe/Mg smectite formation but prevented widespread carbonate formation. The detection of acid sulfates (e.g., jarosite) associated with smectite in Mawrth Vallis supports this hypothesis. Previous work demonstrated smectite (saponite) formation in closed hydrologic systems (batch reactor) from basaltic glass at pH 4 and 200°C (Peretyazhko et al., 2016 GCA). This work presents results from alteration of basaltic glass from alkaline to acidic conditions in open hydrologic systems (flow-through reactor). Preliminary experiments exposed basaltic glass to deionized water at 190°C at 0.25 ml/min where solution pH equilibrated to 9.5. These initial high pH experiments were conducted to evaluate the flow-through reactor system before working with lower pHs. Smectite at this pH was not produced and instead X-ray diffraction results consistent with serpentine was detected. Experiments are in progress exposing basaltic glass from pH 8 down to pH 3 to determine what range of pHs could allow for smectite formation in this experimental open-system. The production of smectite under an experimental open-system at low pHs if successful, would support a significant paradigm shift regarding the geochemical evolution of early Mars: Early Mars geochemical solutions were mildly acidic, not neutral/alkaline. This could have profound implications regarding early martain microbiology where acid conditions instead of neutral/alkaline conditions will require further research in terrestrial analogs to address the potential for biosignature preservation on Mars (Johnson et al., 2016, LPSC).

  14. Acoustic streaming in pulsating flows through porous media

    International Nuclear Information System (INIS)

    Valverde, J.M.; Dura'n-Olivencia, F.J.

    2014-01-01

    When a body immersed in a viscous fluid is subjected to a sound wave (or, equivalently, the body oscillates in the fluid otherwise at rest) a rotational fluid stream develops across a boundary layer nearby the fluid-body interphase. This so-called acoustic streaming phenomenon is responsible for a notable enhancement of heat, mass and momentum transfer and takes place in any process involving two phases subjected to relative oscillations. Understanding the fundamental mechanisms governing acoustic streaming in two-phase flows is of great interest for a wide range of applications such as sonoprocessed fluidized bed reactors, thermoacoustic refrigerators/engines, pulsatile flows through veins/arteries, hemodialysis devices, pipes in off-shore platforms, offshore piers, vibrating structures in the power-generating industry, lab-on-a-chip microfluidics and microgravity acoustic levitation, and solar thermal collectors to name a few. The aim of engineering studies on this vast diversity of systems is oriented towards maximizing the efficiency of each particular process. Even though practical problems are usually approached from disparate disciplines without any apparent linkage, the behavior of these systems is influenced by the same underlying physics. In general, acoustic streaming occurs within the interstices of porous media and usually in the presence of externally imposed steady fluid flows, which gives rise to important effects arising from the interference between viscous boundary layers developed around nearby solid surfaces and the nonlinear coupling between the oscillating and steady flows. This paper is mainly devoted to highlighting the fundamental physics behind acoustic streaming in porous media in order to provide a simple instrument to assess the relevance of this phenomenon in each particular application. The exact microscopic Navier-Stokes equations will be numerically solved for a simplified 2D system consisting of a regular array of oscillating

  15. Removal of organic carbon and nitrogen in a membraneless flow-through microbial electrolysis cell.

    Science.gov (United States)

    Hussain, Abid; Lebrun, Frédérique Matteau; Tartakovsky, Boris

    2017-07-01

    This study evaluated performance of an upflow membraneless microbial electrolysis cell (MEC) with flow-through electrodes for wastewater treatment. First, methane production and COD removal were evaluated in continuous flow experiments carried out using synthetic and municipal wastewater. A 29-75% increase in methane production was observed under bioelectrochemical conditions as compared to an anaerobic control. Next, simultaneous removal of COD and nitrogen was studied under microaerobic conditions created by continuous air injection to the anodic compartment of the MEC. While the presence of oxygen decreased Coulombic efficiency due to aerobic degradation of COD, enhanced ammonium removal with near zero nitrite and nitrate effluent concentrations was observed. Evidence of direct ammonium oxidation at the anode as well as nitrite and nitrate reduction at the cathode was obtained by comparing performances of MECs operated under anaerobic and microaerobic conditions with the control reactor operated at zero applied voltage. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  16. Numerical simulation of water flow through the bottom en piece of a nuclear fuel assembly

    International Nuclear Information System (INIS)

    Navarro, Moyses A.; Santos, Andre A. Campagnole dos

    2007-01-01

    The water flow through the bottom nozzle of a nuclear fuel assembly was simulated using a commercial CFD code, CFX 10.0. Previously, simulations with a perforated plate similar to the bottom nozzle plate were performed to define the appropriate mesh refinement and turbulence model (κ-ε or SST). Subsequently, the numerical simulation was performed with the optimized mesh using the turbulence model (κ-ε in a standard bottom nozzle with some geometric simplifications. The numerical results were compared with experimental results to determine the pressure drop through the bottom nozzle in the Reynolds range from ∼10500 to ∼95000. The agreement between the numerical simulations and experimental results may be considered satisfactory. The study indicated that the CFD codes can play an important role in the development of pieces with complex geometries, optimizing the planning of the experiments and aiding in the experimental analysis. (author)

  17. Synchrotron 4-dimensional imaging of two-phase flow through porous media.

    Science.gov (United States)

    Kim, F H; Penumadu, D; Patel, P; Xiao, X; Garboczi, E J; Moylan, S P; Donmez, M A

    2016-01-01

    Near real-time visualization of complex two-phase flow in a porous medium was demonstrated with dynamic 4-dimensional (4D) (3D + time) imaging at the 2-BM beam line of the Advanced Photon Source (APS) at Argonne National Laboratory. Advancing fluid fronts through tortuous flow paths and their interactions with sand grains were clearly captured, and formations of air bubbles and capillary bridges were visualized. The intense X-ray photon flux of the synchrotron facility made 4D imaging possible, capturing the dynamic evolution of both solid and fluid phases. Computed Tomography (CT) scans were collected every 12 s with a pixel size of 3.25 µm. The experiment was carried out to improve understanding of the physics associated with two-phase flow. The results provide a source of validation data for numerical simulation codes such as Lattice-Boltzmann, which are used to model multi-phase flow through porous media.

  18. Dynamic flow-through approaches for metal fractionation in environmentally relevant solid samples

    DEFF Research Database (Denmark)

    Miró, Manuel; Hansen, Elo Harald; Chomchoei, Roongrat

    2005-01-01

    In the recent decades, batchwise equilibrium-based single or sequential extraction schemes have been consolidated as analytical tools for fractionation analyses to assess the ecotoxicological significance of metal ions in solid environmental samples. However, taking into account that naturally...... generations of flow-injection analysis. Special attention is also paid to a novel, robust, non-invasive approach for on-site continuous sampling of soil solutions, capitalizing on flow-through microdialysis, which presents itself as an appealing complementary approach to the conventional lysimeter experiments....... In addition, a critical comparison between the time-resolved analytical information provided by these novel dynamic extraction procedures and that of the traditional schemes is given and thoroughly discussed in the bulk of the text....

  19. Flow-through SIP - A novel stable isotope probing approach limiting cross-feeding

    Science.gov (United States)

    Mooshammer, Maria; Kitzinger, Katharina; Schintlmeister, Arno; Kjedal, Henrik; Nielsen, Jeppe Lund; Nielsen, Per; Wagner, Michael

    2017-04-01

    Stable isotope probing (SIP) is a widely applied tool to link specific microbial populations to metabolic processes in the environment without the prerequisite of cultivation, which has greatly advanced our understanding of the role of microorganisms in biogeochemical cycling. SIP relies on tracing specific isotopically labeled substrates (e.g., 13C, 15N, 18O) into cellular biomarkers, such as DNA, RNA or phospholipid fatty acids, and is considered to be a robust technique to identify microbial populations that assimilate the labeled substrate. However, cross-feeding can occur when labeled metabolites are released from a primary consumer and then used by other microorganisms. This leads to erroneous identification of organisms that are not directly responsible for the process of interest, but are rather connected to primary consumers via a microbial food web. Here, we introduce a new approach that has the potential to eliminate the effect of cross-feeding in SIP studies and can thus also be used to distinguish primary consumers from other members of microbial food webs. In this approach, a monolayer of microbial cells are placed on a filter membrane, and labeled substrates are supplied by a continuous flow. By means of flow-through, labeled metabolites and degradation products are constantly removed, preventing secondary consumption of the substrate. We present results from a proof-of-concept experiment using nitrifiers from activated sludge as model system, in which we used fluorescence in situ hybridization (FISH) with rRNA-targeted oligonucleotide probes for identification of nitrifiers in combination with nanoscale secondary ion mass spectrometry (NanoSIMS) for visualization of isotope incorporation at the single-cell level. Our results show that flow-through SIP is a promising approach to significantly reduce cross-feeding and secondary substrate consumption in SIP experiments.

  20. One-heater flow-through polymerase chain reaction device by heat pipes cooling.

    Science.gov (United States)

    Chen, Jyh Jian; Liao, Ming Huei; Li, Kun Tze; Shen, Chia Ming

    2015-01-01

    This study describes a novel microfluidic reactor capable of flow-through polymerase chain reactions (PCR). For one-heater PCR devices in previous studies, comprehensive simulations and experiments for the chip geometry and the heater arrangement were usually needed before the fabrication of the device. In order to improve the flexibility of the one-heater PCR device, two heat pipes with one fan are used to create the requisite temperature regions in our device. With the integration of one heater onto the chip, the high temperature required for the denaturation stage can be generated at the chip center. By arranging the heat pipes on the opposite sides of the chip, the low temperature needed for the annealing stage is easy to regulate. Numerical calculations and thermal measurements have shown that the temperature distribution in the five-temperature-region PCR chip would be suitable for DNA amplification. In order to ensure temperature uniformity at specific reaction regions, the Re of the sample flow is less than 1. When the microchannel width increases and then decreases gradually between the denaturation and annealing regions, the extension region located in the enlarged part of the channel can be observed numerically and experimentally. From the simulations, the residence time at the extension region with the enlarged channel is 4.25 times longer than that without an enlarged channel at a flow rate of 2 μl/min. The treated surfaces of the flow-through microchannel are characterized using the water contact angle, while the effects of the hydrophilicity of the treated polydimethylsiloxane (PDMS) microchannels on PCR efficiency are determined using gel electrophoresis. By increasing the hydrophilicity of the channel surface after immersing the PDMS substrates into Tween 20 (20%) or BSA (1 mg/ml) solutions, efficient amplifications of DNA segments were proved to occur in our chip device. To our knowledge, our group is the first to introduce heat pipes into

  1. An Investigation of Parallel Post-Laminar Flow through Coarse Granular Porous Media with the Wilkins Equation

    Directory of Open Access Journals (Sweden)

    Ashes Banerjee

    2018-02-01

    Full Text Available Behaviour of flow resistance with velocity is still undefined for post-laminar flow through coarse granular media. This can cause considerable errors during flow measurements in situations like rock fill dams, water filters, pumping wells, oil and gas exploration, and so on. Keeping the non-deviating nature of Wilkins coefficients with the hydraulic radius of media in mind, the present study further explores their behaviour to independently varying media size and porosity, subjected to parallel post-laminar flow through granular media. Furthermore, an attempt is made to simulate the post-laminar flow conditions with the help of a Computational Fluid Dynamic (CFD Model in ANSYS FLUENT, since conducting large-scale experiments are often costly and time-consuming. The model output and the experimental results are found to be in good agreement. Percentage deviations between the experimental and numerical results are found to be in the considerable range. Furthermore, the simulation results are statistically validated with the experimental results using the standard ‘Z-test’. The output from the model advocates the importance and applicability of CFD modelling in understanding post-laminar flow through granular media.

  2. Three-dimensional modeling of flow through fractured tuff at Fran Ridge

    International Nuclear Information System (INIS)

    Eaton, R.R.; Ho, C.K.; Glass, R.J.; Nicholl, M.J.; Arnold, B.W.

    1996-01-01

    Numerical studies have been made of an infiltration experiment at Fran Ridge using the TOUGH2 code to aid in the selection of computational models for performance assessment. The exercise investigates the capabilities of TOUGH2 to model transient flows through highly fractured tuff and provides a possible means of calibration. Two distinctly different conceptual models were used in the TOUGH2 code, the dual permeability model and the equivalent continuum model. The infiltration test modeled involved the infiltration of dyed ponded water for 36 minutes. The 205 gallon filtration of water observed in the experiment was subsequently modeled using measured Fran Ridge fracture frequencies, and a specified fracture aperture of 285 μm. The dual permeability formulation predicted considerable infiltration along the fracture network, which was in agreement with the experimental observations. As expected, minimal fracture penetration of the infiltrating water was calculated using the equivalent continuum model, thus demonstrating that this model is not appropriate for modeling the highly transient experiment. It is therefore recommended that the dual permeability model be given priority when computing high-flux infiltration for use in performance assessment studies

  3. Three-dimensional modeling of flow through fractured tuff at Fran Ridge

    International Nuclear Information System (INIS)

    Eaton, R.R.; Ho, C.K.; Glass, RJ.; Nicholl, M.J.; Arnold, B.W.

    1996-09-01

    Numerical studies have been made of an infiltration experiment at Fran Ridge using the TOUGH2 code to aid in the selection of computational models for performance assessment. The exercise investigates the capabilities of TOUGH2 to model transient flows through highly fractured tuff and provides a possible means of calibration. Two distinctly different conceptual models were used in the TOUGH2 code, the dual permeability model and the equivalent continuum model. The infiltration test modeled involved the infiltration of dyed ponded water for 36 minutes. The 205 gallon infiltration of water observed in the experiment was subsequently modeled using measured Fran Ridge fracture frequencies, and a specified fracture aperture of 285 microm. The dual permeability formulation predicted considerable infiltration along the fracture network, which was in agreement with the experimental observations. As expected, al fracture penetration of the infiltrating water was calculated using the equivalent continuum model, thus demonstrating that this model is not appropriate for modeling the highly transient experiment. It is therefore recommended that the dual permeability model be given priority when computing high-flux infiltration for use in performance assessment studies

  4. Stability of fluid flow through deformable tubes and channels: An ...

    Indian Academy of Sciences (India)

    The subject is certainly more than five decades old, and arguably began with Kramer's pioneering experiments on drag reduction by compliant surfaces. This was immediately followed by the theoretical studies of Benjamin and Landhal in the early 1960s. Most earlier theoretical studies were focused on stability of external ...

  5. Pressure drop and He II flow through fine mesh screens

    Science.gov (United States)

    Maddocks, J. R.; van Sciver, S. W.

    1989-05-01

    Fluid acquisition systems for He II transfer devices will utilize gallery arms to ensure that the fluid encounters the pump inlet. In near term experiments such as Superfluid Helium on Orbit Transfer (SHOOT), the preferred configuration consists of several rectangular channels which have one side made from a Dutch weave stainless steel screen having 325 x 2300 wires per inch. The effective pore diameter for this screen is about 5 microns. The present paper reports on measurements of pressure drop across a screen when it is subjected to a flow of liquid helium. The experiment measures the time rate of change of the level in two different helium reservoirs connected by a screen-blocked channel. Results with normal helium are compared with predictions based on the Armour-Cannon (1968) equations. The He II data show considerable deviation from the classical result. A discussion of the He II pressure drop results in terms of two fluid hydrodynamics is included.

  6. Pressure driven water flow through hydrophilic alumina nanomembranes

    Science.gov (United States)

    Beskok, Ali; Koklu, Anil; Sengor, Sevinc

    2017-11-01

    We present an experimental study that focuses on pressure-driven flow of distilled water through alumina membranes with 5, 10 and 20 nm pore radii. The nanopore geometry, pore size and porosity are characterized using scanning electron microscopy images taken pre and post-flow experiments. Comparisons of these images have shown reduction in the pore size, which is attributed to precipitation of hydroxyl groups on alumina surfaces. Measured flowrates compared with the Hagen-Poiseuille flow relations consistently predict 2.2 nm reductions in the pore size for three different membranes. This behavior can be explained by the formation of a thick stick layer of water molecules over hydroxylated alumina surfaces, evidenced by water droplet contact angle measurements that exhibit increased hydrophilicity of alumina surfaces. Other possible effects of the mismatch between theory and experiments such as unaccounted pressure losses in the system or the streaming potential effects were also considered, but shown to be negligible for current experimental conditions.

  7. Gas-Liquid Two-Phase Flows Through Packed Bed Reactors in Microgravity

    Science.gov (United States)

    Motil, Brian J.; Balakotaiah, Vemuri

    2001-01-01

    The simultaneous flow of gas and liquid through a fixed bed of particles occurs in many unit operations of interest to the designers of space-based as well as terrestrial equipment. Examples include separation columns, gas-liquid reactors, humidification, drying, extraction, and leaching. These operations are critical to a wide variety of industries such as petroleum, pharmaceutical, mining, biological, and chemical. NASA recognizes that similar operations will need to be performed in space and on planetary bodies such as Mars if we are to achieve our goals of human exploration and the development of space. The goal of this research is to understand how to apply our current understanding of two-phase fluid flow through fixed-bed reactors to zero- or partial-gravity environments. Previous experiments by NASA have shown that reactors designed to work on Earth do not necessarily function in a similar manner in space. Two experiments, the Water Processor Assembly and the Volatile Removal Assembly have encountered difficulties in predicting and controlling the distribution of the phases (a crucial element in the operation of this type of reactor) as well as the overall pressure drop.

  8. A constitutive model for the flow through an assembly of circular section rods

    International Nuclear Information System (INIS)

    Moeller, S.V.

    1979-08-01

    The determination of the flow through an uniform array of rod bundle is made by means of the Continuum Theories of Mixtures, which gives balance equations for the system. The hypotheses of isothermal and fully developed turbulent flow are made. Constitutive equations for the resistive force are determined from Jakob's and Rowe's correlations, and its behaviour analysed for a standard case. Comparison of these equations with Bottgenbach's experiments shows good agreement of the direction of the pressure, although direct comparison between present theory and his theory is not possible. For the confirmation of the model an experiment is performed, this consisting of measuring pressure drop (Euler's Number) in the axial and transverse direction of a random array rod bundle at various angles as functions of velocity (Reynold's Number), which has good agreement, except on axial direction. At last, a sample problem is formulated with the purpose of showing the applicability of the model, this being the determination of pressure field due to the influence of a baffle. (Author) [pt

  9. Application of chemical oxidation to remediate HCH-contaminated soil under batch and flow through conditions.

    Science.gov (United States)

    Usman, Muhammad; Tascone, Oriane; Rybnikova, Victoria; Faure, Pierre; Hanna, Khalil

    2017-06-01

    This is the first study describing the chemical oxidation of hexachlorocyclohexanes (HCHs) in contaminated soil under water saturated and unsaturated flow through conditions. Soil contaminated with β-HCH (45 mg kg -1 ) and γ-HCH (lindane, 25 mg kg -1 ) was sampled from former lindane waste storage site. Efficiency of following treatments was tested at circumneutral pH: H 2 O 2 alone, H 2 O 2 /Fe II , Na 2 S 2 O 8 alone, Na 2 S 2 O 8 /Fe II , and KMnO 4 . Experimental conditions (oxidant dose, liquid/solid ratio, and soil granulometry) were first optimized in batch experiments. Obtained results revealed that increasing dose of H 2 O 2 improved the oxidation efficiency while in Na 2 S 2 O 8 system, maximum HCHs were removed at 300 mM. However, oxidation efficiency was slightly improved by Fe II -activation. Increasing the solid/liquid ratio decreased HCH removal in soil samples crushed to 500 μm while an opposite trend was observed for 2-mm samples. Dynamic column experiments showed that oxidation efficiency followed the order KMnO 4  > Na 2 S 2 O 8 /Fe II  > Na 2 S 2 O 8 whatever the flow condition, whereas the removal extent declined at higher flow rate (e.g., ~50% by KMnO 4 at 0.5 mL/min as compared to ~30% at 2 mL/min). Both HCH removal and oxidant decomposition extents were found higher in saturated columns than the unsaturated ones. While no significant change in relative abundance of soil mineral constituents was observed before and after chemical oxidation, more than 60% of extractable organic matter was lost after chemical oxidation, thereby underscoring the non-selective behavior of chemical oxidation in soil. Due to the complexity of soil system, chemical oxidation has rarely been reported under flow through conditions, and therefore our findings will have promising implications in developing remediation techniques under dynamic conditions closer to field applications.

  10. Pressure drop of He II flow through a porous media

    Science.gov (United States)

    Maddocks, J. R.; van Sciver, S. W.

    The paper reports on measurements of He II pressure drop across two porous SiO2 ceramic filter materials. These materials vary only in porosity, having values of 0.94 and 0.96. The average fiber diameter in both cases is approximately 5 microns. The experiment consists of a glass tube containing a piece of this sponge in one end. The tube is rapidly displaced downward in a bath of helium and the liquid levels are allowed to equilibrate over time producing variable velocities up to 10 cm/sec. The results are compared with those previously obtained using fine mesh screens. Good qualitative agreement is observed for turbulent flow; however, the behavior in the laminar flow regime is not fully understood.

  11. Clogging arches in grains, colloids, and pedestrians flowing through constrictions

    Science.gov (United States)

    Zuriguel, Iker

    When a group of particles pass through a narrow orifice, the flow might become intermittent due to the development of clogs that obstruct the constriction. This effect has been observed in many different fields such as mining transport, microbial growing, crowd dynamics, colloids, granular and active matter. In this work we introduce a general framework in which research in some of such scenarios can be encompassed. In particular, we analyze the statistical properties of the bottleneck flow in different experiments and simulations: granular media within vibrated silos, colloids, a flock of sheep and pedestrian evacuations. We reveal a common phenomenology that allows us to rigorously define a transition to a clogged state. Using this definition we explore the main variables involved, which are then grouped into three generic parameters. In addition, we will present results of the geometrical characteristics that the clogging arches have which are related with their stability against perturbations. We experimentally analyse the temporal evolution of the arches evidencing important differences among the structures that are easily destroyed and those that seem to resist forever (longer than the temporal window employed in our measurements). Ministerio de Economía y Competitividad (Spanish Government). Project No. FIS2014-57325.

  12. Laminar Flow Through Circular Tubes with Side Inlets

    Science.gov (United States)

    Abedian, Behrouz; Muhlanger, Eric

    2004-11-01

    We discuss experimental results on steady axisymmetric flow of a Newtonian incompressible fluid through circular pipes with side inlets. Circular tubes with a set of holes along their sidewalls are used in a number of medical procedures as straight catheters to transfer fluid into or out of the human body. For example, because of the small size of the incision required, they are commonly used in peritoneal dialysis. The internal diameter and the diameter of the side holes are often 1 mm and less, and as a result, the fluid flow is laminar in a typical medical procedure. An understanding of the flow inside the catheter tube in terms of its geometric parameters will be key in designing new catheters with optimal clinical performance for specific applications. In the experiments, water is withdrawn from a smooth tube with side holes and the local axial pressure and flow rates through the side holes are measured for different flow conditions. A nondimensionalization of the data shows a power-law behavior in only some cases. Using numerical simulations, it is shown how the interaction of the axial flow with the impinging jets from the side holes can change the overall behavior of the flow for a given suction pressure.

  13. Experimental investigations on transient single phase flow through perforated plates

    International Nuclear Information System (INIS)

    Casadei, F.

    1983-01-01

    The transient flow of the coolant through the perforated dip-plate during a HCDA in a LMFBR was simulated in a one-dimensional experimental model. Several experiments with water as fluid and with various perforation ratios of the dip-plate and different initial heights of the fluid head over the dip-plate were run. The pressure drop across the dip-plate and the forces acting on the dip-plate and on the upper plug of the reactor vessel were measured in a wide range of the Reynolds and Strouhal numbers. The flow pattern downstreams the perforated plate was filmed with high-speed cameras. The resistance coefficients for the transient flow of the coolant through the perforated plate were obtained as a function of the acceleration. The forces acting on the upper plug and their time integral were compared with those acting on the dip-plate. Finally, using high-speed film pictures the formation of fluid jets downstream the dip-plate was investigated. (orig.)

  14. Accelerated one-phase flow through perforated plates

    International Nuclear Information System (INIS)

    Casadei, F.; Dalle Donne, M.

    1984-01-01

    The coolant flow across the perforated dip-plate during a hypothetical core disruptive accident in a liquid-metal fast breeder reactor was simulated in a one-dimensional model. Several experiments with water as fluid and with various perforation ratios of the dip-plate and different initial heights of the fluid head over the dip-plate were run. The pressure drop across the dip-plate and the forces acting on the dipplate and on the upper plug of the reactor vessel were measured in a wide range of Reynolds and Strouhal numbers and of an acceleration parameter. The flow pattern downstream from the perforated plate was filmed with a high-speed camera. The resistance coefficients for the transient flow of the coolant through the perforated plate were obtained as a function of the acceleration. The forces acting on the upper plug and their time integral were compared with those acting on the dip-plate. Finally, using highspeed film pictures, the formation of fluid jets downstream from the dip-plate was investigated

  15. Investigation of the flow through an axial turbine stage

    Energy Technology Data Exchange (ETDEWEB)

    Svensdotter, S.; Wei Ning [Royal Inst. of Tech., Stockholm (Sweden). Dept. of Energy Technology

    1995-12-31

    In this licentiate thesis the classical turbine theory and experimental results from the test turbine at KTH have been studied. The theory for the data evaluation program has also been studied and the loss models by Traupel and Denton have been investigated and applied to the measured results. The work has been performed to prepare for a theory concerning aerodynamic design of so called compound leaned blades and for future experiments on this non-conventional blade design with a new measurement system. A literature survey shows that the compound lean can be an effective three-dimensional technique in turbine designs, with significantly improved flow conditions, especially near the end-wall regions. A new measurement system, PSI, has been installed and the first preliminary tests shows good agreement with the existing system. The speed of the global measurements has been improved from about 10 minutes to about 12 seconds. The system reliability and documentation is also improved with the PSI system. The accuracy of the PSI-system is significantly better on the pressure measurement side, while the analogue side has somewhat less accuracy for the moment. From the analysis of the measurement results on the 25 mm stage, the tendencies of parameter variation versus pressure and velocity ratios were gained by the authors. The results show high secondary flow loss cores near the end-walls downstream the stator. The result is similar with those from the literature survey. The radial positions of the secondary flow cores change when simulating stator leakage flow. 140 refs, 54 figs, 14 tabs, 14 appendices

  16. Flow-through devices for the ac electrokinetic construction of microstructured materials

    Science.gov (United States)

    Flores-Rodriguez, N.; Markx, G. H.

    2006-02-01

    With the aid of computer simulation, flow-through devices have been devised for the continuous construction of microstructured materials using non-uniform ac electric fields. Particles can be concentrated and guided along channels defined by non-uniform electric fields generated between microelectrodes. The resulting streams of particles emanating from the microelectrode structures can subsequently be immobilized to form materials with particles embedded in defined locations. Experiments with latex beads with a diameter of 6 µm, suspended in high purity low-melting agarose at a concentration of 0.75% and temperatures over 60 °C, showed that a linear stream of particles can be created by the combined application of negative dielectrophoresis and hydrodynamic flow forces. By guiding the stream of particles onto a conveyor, it was then possible to create a continuous film of agarose containing latex beads in defined positions. Potential applications of the method in the creation of biomaterials such as tissues and biofilms are discussed.

  17. Friction factor for water flow through packed beds of spherical and non-spherical particles

    Directory of Open Access Journals (Sweden)

    Kaluđerović-Radoičić Tatjana

    2017-01-01

    Full Text Available The aim of this work was the experimental evaluation of different friction factor correlations for water flow through packed beds of spherical and non-spherical particles at ambient temperature. The experiments were performed by measuring the pressure drop across the bed. Packed beds made of monosized glass spherical particles of seven different diameters were used, as well as beds made of 16 fractions of quartz filtration sand obtained by sieving (polydisperse non-spherical particles. The range of bed voidages was 0.359–0.486, while the range of bed particle Reynolds numbers was from 0.3 to 286 for spherical particles and from 0.1 to 50 for non-spherical particles. The obtained results were compared using a number of available literature correlations. In order to improve the correlation results for spherical particles, a new simple equation was proposed in the form of Ergun’s equation, with modified coefficients. The new correlation had a mean absolute deviation between experimental and calculated values of pressure drop of 9.04%. For non-spherical quartz filtration sand particles the best fit was obtained using Ergun’s equation, with a mean absolute deviation of 10.36%. Surface-volume diameter (dSV necessary for correlating the data for filtration sand particles was calculated based on correlations for dV = f(dm and Ψ = f(dm. [Project of the Serbian Ministry of Education, Science and Technological Development, Grant no. ON172022

  18. Perennial flow through convergent hillslopes explains chemodynamic solute behavior in a shale headwater catchment

    Science.gov (United States)

    Herndon, E.; Steinhoefel, G.; Dere, A. L. D.; Sullivan, P. L.

    2017-12-01

    Streams experience changing hydrologic connectivity to heterogeneous water sources under different flow regimes. It remains unclear how seasonal flow paths link these different sources and regulate concentration-discharge behavior. Previous research at the Susquehanna Shale Hills Critical Zone Observatory (SSHCZO) in central Pennsylvania, USA identified chemostatic solutes (e.g., K, Mg, Na, Cl) whose concentrations varied little across a wide range of discharge values and chemodynamic solutes (e.g., Fe and Mn) whose concentrations decreased sharply with increasing stream discharge. To elucidate inputs to the stream when concentrations of chemodynamic solutes were high, we investigated stream water and shallow groundwater (table remained over a meter below the stream bed along the rest of the channel. We conclude that well water sampled from the upper catchment is young, shallow interflow that upwells to generate metal-rich stream headwaters during the dry season. High concentrations of chemodynamic solutes measured during low discharge occur when metal-rich headwaters are flushed to the catchment outlet during periodic rain events. Interflow during the dry season originates from water that infiltrates through organic-rich swales; thus, metals in the stream at low flow are ultimately derived from convergent hillslopes where biological processes have concentrated chemodynamic elements. We infer that chemodynamic solutes are diluted at high discharge due to increased flow through planar hillslopes and inputs from regional groundwater that rises to enter the stream. This study highlights how spatially heterogeneous biogeochemistry and seasonally variable flow paths regulate concentration-discharge behavior within catchments.

  19. Rapid detection of defects in fuel-cell electrodes using infrared reactive-flow-through technique

    Science.gov (United States)

    Das, Prodip K.; Weber, Adam Z.; Bender, Guido; Manak, Austin; Bittinat, Daniel; Herring, Andrew M.; Ulsh, Michael

    2014-09-01

    As fuel cells become more prominent, new manufacturing and production methods will need to be developed to deal efficiently and effectively with increased demand. One necessary component of this industrial growth is the accurate measurement of the variability in the manufacturing process. In this study, we present a diagnostic system that combines infrared thermography with a reactive-flow-through technique to detect catalyst-loading defects in fuel-cell gas-diffusion electrodes accurately with high spatial and temporal resolutions. Experimental results are compared with model predictions of thermal response with good agreement. Data analysis, operating-condition impacts, and detection limits are explored using both experiments and simulation. Overall, the results demonstrate the potential of this technique to measure defects on the millimeter length scale with temporal resolutions appropriate for use on a web-line. Thus we present the first development stage of a next-generation non-destructive diagnostic tool, which may be amenable to eventual use on roll-to-roll manufacturing lines.

  20. Identification of significant process variables for a flow-through supercritical water oxidation reactor

    International Nuclear Information System (INIS)

    Rossi, R.E.

    1992-05-01

    The effects of four process variables on the destruction efficiency of a flow-through supercritical water oxidation reactor were investigated. These process variables included: (1) reactor throughput (GPH), (2) concentration of the surrogate waste (% acetone), (3) maximum reactor tube-wall temperature (OC), and (4) applied stoichiometric oxygen. The analysis was conducted utilizing two-level factorial experiments, steepest ascent methods, and central composite designs. This experimental protocol assures efficient experimentation and allows for an empirical response surface model of the system to be developed. This experimentation identified a significant positive effect for stoichiometric oxygen applied and temperature variations between 400 to 500 degrees C. The increase in destruction efficiency due to stoichiometric 0 2 provides strong evidence that supercritical water oxidations are catalyzed by excess oxygen, and the strong temperature effect is a result of large increases in the kinetic rates for this temperature range. However, increasing temperature between 550 to 650 degrees C does not provide substantial increases in destruction efficiency. In addition, destruction efficiency is significantly unproved by increasing the Reynolds number and residence time. The destruction efficiency of the reactor is also dependent upon the initial concentration of surrogate waste. This concentration dependence may indicate first-order supercritical CO kinetics is inadequate for describing all waste types and reactor configurations. Alternatively, it may indicate reactant mixing, caused by local turbulence at the oxidation fronts of these higher concentration waste streams, results in higher destruction efficiencies

  1. Large-Eddy Simulation of Flows Through a Novel Vascular Access Device for Hemodialysis Access

    Science.gov (United States)

    Obabko, Aleksandr; Tsyrulnykov, Eduard; Rainsberger, Robert; Torreira, Alvaro V.; Nagib, Hassan; Agarwal, Anil; Fischer, Paul F.

    2017-11-01

    The preferred vascular access in patients on hemodialysis (HD) is an arteriovenous (AV) fistula or graft. The majority of the HD patients in the US are dialyzed with an AV fistula where two needles are used for cannulation in most cases. However, this approach can be painfully invasive, extremely difficult to gain access in patients with challenging geometry of vascular access, and is often inadequate to provide optimal blood flow. This work attempts to address the shortcomings of the above procedure and introduces a novel cannulation device that allows less painful easy single access to difficult vessel geometries, and have a potential of improvement of overall increase in efficacy of HD and enhanced patient experience. We present the preliminary Nek5000 large-eddy simulations results of the flows through the device that employs a single 18-gauge needle for cannulation and is able to provide blood flow rates up to 600 ml/min. The range of flow rates and Reynolds numbers up to Re=2,600 are considered and blood recirculation rates are computed. This research used resources of the Argonne Leadership Computing Facility and was supported in part by the U.S. DOE Office of Science under Contract DE-AC02-06CH11357.

  2. Experimental study of mixed convection flow through a horizontal orifice or vent linking two compartments

    International Nuclear Information System (INIS)

    Varrall, Kevin

    2016-01-01

    To answer building issues and fire safety challenges, this thesis deals with the mixed convection flow through a horizontal orifice or vent linking two compartments. The aim is to improve the understanding and the modeling of the exchange of gas through the opening. A small scale experimental study and a theoretical approach are proposed. The study focuses first on the influence of the geometrical ratio L/D of the opening on the flow rate at the vent for free convection regime. Non-intrusive measurements, via the tracking of the interface between two non miscible liquids in an isothermal approach, and thanks to the SPIV in a thermal approach, permit to describe the bidirectional exchange process and to consolidate existing correlations. Experiments for mixed convection regime aim to study the impact of mechanical ventilation (in blowing and extracting modes) on the exchanged flow rates. The comparison between existing correlations and experimental data shows large differences. A modification of the correlation of Cooper is proposed. A theoretical approach from the simplified Navier Stokes equations and with the Boussinesq approximation permits to discuss the construction of existing correlations. From this theory, a more accurate model than those available in the literature is proposed thanks to an adjustment of discharge coefficients from experimental data. (author)

  3. Measurement and modeling of flow through unsaturated heterogeneous rock in the context of geologic disposal of nuclear waste

    International Nuclear Information System (INIS)

    Sagar, B.; Bagtzoglou, A.C.; Green, R.T.; Stothoff, S.A.

    1995-01-01

    Deep geologic disposal of high-level and transuranic waste is currently being pursued vigorously. Assessing long-term performance of such repositories involves laboratory and field measurements, and numerical modeling. There exist two primary characteristics, associated with assessing repository performance, that define problems of modeling and measurement of non-isothermal flow through geologic media exposed to variable boundary conditions (e.g., climatic changes). These are: (1) the large time scale (tens of thousands of years) and highly variable space scale (from one meter to 10 5 meters); and (2) the hierarchy of heterogeneities and discontinuities characterizing the medium. This paper provides an overview of recent work, conducted at the Center for Nuclear Waste Regulatory Analyses (CNWRA), related to laboratory experiments, consideration of similitude, and numerical modeling of flow through heterogeneous media under non-homogeneous boundary conditions. As discussed, there exist neither good methods of measuring flows at these scales nor are there adequate similitude analyses that would allow reasonable scaling up of laboratory-scale experiments. Reliable assessment of long-term geologic repositories will require sophisticated geostatistical models capable of addressing variables scales of heterogeneities conditioned with observed results from adequately sized field-scale experiments conducted for sufficiently long durations

  4. Space-charge-limited ion flow through an ionizing neutral layer

    International Nuclear Information System (INIS)

    Duvall, R.E.; Litwin, C.; Maron, Y.

    1993-01-01

    Space-charge-limited ion flow through an ionizing layer of neutral atoms is studied. The ion flow is between two parallel conducting plates (anode and cathode) with an externally applied voltage between them. An expanding layer of neutral atoms is adjacent to the anode surface, extending a finite distance into the anode--cathode gap. All ions originate either from the anode surface or from the ionization of neutrals; electrons originate only from ionization. Electrons are strongly magnetized by an externally applied, time-independent direct current (dc) magnetic field directed across the ion flow. The ions are unmagnetized, all motion being perpendicular to the conducting plates. Two different models of the anode layer were used to analyze this problem: a multifluid steady-state model and a single fluid time-dependent model. From both models it was found that the anode surface becomes shielded after the ion flux from the ionizing layer becomes larger than the space-charge-limited flux of the reduced gap between the neutral layer and cathode. Comparison was made between the time-dependent model and results from magnetically insulated ion beam diode (MID) experiments. Using an initial areal density of neutral hydrogen and carbon equal to the final observed electron areal density, comparison was made between calculated plasma shielding times and upper bounds on the shielding time observed in experiments. It was found that a layer of neutral hydrogen must contain a minimum of 15% carbon (by number density) to explain the rapid electric field screening observed in experiments

  5. A Comparison of Flow-Through Versus Non-Flow-Through Proton Exchange Membrane Fuel Cell Systems for NASA's Exploration Missions

    Science.gov (United States)

    Hoberecht, Mark A.

    2010-01-01

    As part of the Exploration Technology Development Program (ETDP) under the auspices of the Exploration Systems Mission Directorate (ESMD), NASA is developing both primary fuel cell power systems and regenerative fuel cell (RFC) energy storage systems within the fuel cell portion of the Energy Storage Project. This effort is being led by the NASA Glenn Research Center (GRC) in partnership with the NASA Johnson Space Center (JSC), Jet Propulsion Laboratory (JPL), NASA Kennedy Space Center (KSC), and industrial partners. The development goals are to improve fuel cell and electrolysis stack electrical performance, reduce system mass, volume, and parasitic power requirements, and increase system life and reliability. A major focus of this effort has been the parallel development of both flow-through and non-flow-through proton exchange membrane (PEM) primary fuel cell power systems. The plan has been, at the appropriate time, to select a single primary fuel cell technology for eventual flight hardware development. Ideally, that appropriate time would occur after both technologies have achieved a technology readiness level (TRL) of six, which represents an engineering model fidelity PEM fuel cell system being successfully tested in a relevant environment. Budget constraints in fiscal year 2009 and beyond have prevented NASA from continuing to pursue the parallel development of both primary fuel cell options. Because very limited data exists for either system, a toplevel, qualitative assessment based on engineering judgement was performed expeditiously to provide guidance for a selection. At that time, the non-flow-through technology was selected for continued development because of potentially major advantages in terms of weight, volume, parasitic power, reliability, and life. This author believes that the advantages are significant enough, and the potential benefits great enough, to offset the higher state of technology readiness of flow-through technology. This paper

  6. Comparing flow-through and static ice cave models for Shoshone Ice Cave

    Directory of Open Access Journals (Sweden)

    Kaj E. Williams

    2015-05-01

    Full Text Available In this paper we suggest a new ice cave type: the “flow-through” ice cave. In a flow-through ice cave external winds blow into the cave and wet cave walls chill the incoming air to the wet-bulb temperature, thereby achieving extra cooling of the cave air. We have investigated an ice cave in Idaho, located in a lava tube that is reported to have airflow through porous wet end-walls and could therefore be a flow-through cave. We have instrumented the site and collected data for one year. In order to determine the actual ice cave type present at Shoshone, we have constructed numerical models for static and flow-through caves (dynamic is not relevant here. The models are driven with exterior measurements of air temperature, relative humidity and wind speed. The model output is interior air temperature and relative humidity. We then compare the output of both models to the measured interior air temperatures and relative humidity. While both the flow-through and static cave models are capable of preserving ice year-round (a net zero or positive ice mass balance, both models show very different cave air temperature and relative humidity output. We find the empirical data support a hybrid model of the static and flow-through models: permitting a static ice cave to have incoming air chilled to the wet-bulb temperature fits the data best for the Shoshone Ice Cave.

  7. The chromatographic performance of flow-through particles: A computational fluid dynamics study.

    Science.gov (United States)

    Smits, Wim; Nakanishi, Kazuki; Desmet, Gert

    2016-01-15

    The performance of flow-through particles has been studied by computational fluid dynamics. Computational fluid dynamics simulations was used to calculate the flow behaviour around and inside the particles rather than estimate it. The obtained flow field has been used to accurately simulate plate heights generated by flow-through particles and compare them to standard fully porous particles. The effects of particle size, particle porosity and microparticle size on the intra-particle flow and plate heights is investigated. It is shown that the intra-particle flow generates mass transfer enhancement which lowers the total plate height. An empirical model is proposed for the mass transfer enhancement and it is compared to previously proposed models. Kinetic plots are constructed for the flow-through particles. Counter-intuitively, columns packed with flow-through particles have a higher flow resistance which counters the advantages of lower plate heights. Flow-through particles offer no significant gain in kinetic performance over fully porous particles. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Disposable and removable nucleic acid extraction and purification cartridges for automated flow-through systems

    Science.gov (United States)

    Regan, John Frederick

    2014-09-09

    Removable cartridges are used on automated flow-through systems for the purpose of extracting and purifying genetic material from complex matrices. Different types of cartridges are paired with specific automated protocols to concentrate, extract, and purifying pathogenic or human genetic material. Their flow-through nature allows large quantities sample to be processed. Matrices may be filtered using size exclusion and/or affinity filters to concentrate the pathogen of interest. Lysed material is ultimately passed through a filter to remove the insoluble material before the soluble genetic material is delivered past a silica-like membrane that binds the genetic material, where it is washed, dried, and eluted. Cartridges are inserted into the housing areas of flow-through automated instruments, which are equipped with sensors to ensure proper placement and usage of the cartridges. Properly inserted cartridges create fluid- and air-tight seals with the flow lines of an automated instrument.

  9. Non-Flow-Through Fuel Cell System Test Results and Demonstration on the SCARAB Rover

    Science.gov (United States)

    Scheidegger, Brianne, T.; Burke, Kenneth A.; Jakupca, Ian J.

    2012-01-01

    This paper describes the results of the demonstration of a non-flow-through PEM fuel cell as part of a power system on the SCARAB rover. A 16-cell non-flow-through fuel cell stack from Infinity Fuel Cell and Hydrogen, Inc. was incorporated into a power system designed to act as a range extender by providing power to the rover s hotel loads. This work represents the first attempt at a ground demonstration of this new technology aboard a mobile test platform. Development and demonstration were supported by the Office of the Chief Technologist s Space Power Systems Project and the Advanced Exploration System Modular Power Systems Project.

  10. Test Methodologies for Hydrogen Sensor Performance Assessment: Chamber vs. Flow Through Test Apparatus: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Buttner, William J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Hartmann, Kevin S [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Schmidt, Kara [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Cebolla, Rafeal O [Joint Research Centre, Petten, the Netherlands; Weidner, Eveline [Joint Research Centre, Petten, the Netherlands; Bonato, Christian [Joint Research Centre, Petten, the Netherlands

    2017-11-06

    Certification of hydrogen sensors to standards often prescribes using large-volume test chambers [1, 2]. However, feedback from stakeholders such as sensor manufacturers and end-users indicate that chamber test methods are often viewed as too slow and expensive for routine assessment. Flow through test methods potentially are an efficient, cost-effective alternative for sensor performance assessment. A large number of sensors can be simultaneously tested, in series or in parallel, with an appropriate flow through test fixture. The recent development of sensors with response times of less than 1s mandates improvements in equipment and methodology to properly capture the performance of this new generation of fast sensors; flow methods are a viable approach for accurate response and recovery time determinations, but there are potential drawbacks. According to ISO 26142 [1], flow through test methods may not properly simulate ambient applications. In chamber test methods, gas transport to the sensor can be dominated by diffusion which is viewed by some users as mimicking deployment in rooms and other confined spaces. Alternatively, in flow through methods, forced flow transports the gas to the sensing element. The advective flow dynamics may induce changes in the sensor behaviour relative to the quasi-quiescent condition that may prevail in chamber test methods. One goal of the current activity in the JRC and NREL sensor laboratories [3, 4] is to develop a validated flow through apparatus and methods for hydrogen sensor performance testing. In addition to minimizing the impact on sensor behaviour induced by differences in flow dynamics, challenges associated with flow through methods include the ability to control environmental parameters (humidity, pressure and temperature) during the test and changes in the test gas composition induced by chemical reactions with upstream sensors. Guidelines on flow through test apparatus design and protocols for the evaluation of

  11. Use of HPLC with flow-through radiometric detection for low level environmental analysis

    International Nuclear Information System (INIS)

    Mao, J.; Fackler, P.H.

    1992-01-01

    High Performance Liquid Chromatography with flow-through radiometric detection (HPLC-RAM) is increasingly becoming a standard analytical technique in pharmaceutical, agricultural and chemical industries for monitoring radiolabeled analytes. This paper focuses on the applications of this flow-through radiochromatographic technique for low level aquatic toxicology and environmental fate testing. Examples include parts per billion water, sediment/soil and fish tissue analyses using reverse phase as well as normal phase HPLC. The applications of both homogeneous (liquid) and heterogeneous (solid) flow cell scintillation counting are addressed. Compounds discussed are primarily pesticides and pharmaceuticals

  12. Dynamic flow-through approach to evaluate readily bioaccessible antioxidants in solid food samples.

    Science.gov (United States)

    Maia, Miguel A; Soares, Tânia R P; Mota, Ana I P; Rosende, María; Magalhães, Luís M; Miró, Manuel; Segundo, Marcela A

    2017-05-01

    Release of bioactive compounds from food matrices is regarded as the first step towards their human bioavailability. The objective of this work was the implementation of an affordable and robust flow-through device for expedient dynamic leaching experiments aiming at the assessment of readily bioaccessible antioxidant compounds in solid food commodities. A simple configuration is proposed using commercially available devices containing regenerated cellulose filters placed in polypropylene holders to entrap the solid sample, featuring a disposable, single use extraction chamber. The kinetic extraction profile of fast leachable antioxidants from different food matrices was evaluated using the ABTS (2,2'-azino-bis-(3-ethylbenzothiazoline-6-sulfonic acid)) assay, fitting a first-order reaction model for readily bioaccessible compounds (R>0.9). The leaching rate constant values associated to the fast leachable antioxidant compounds were 0.060-0.446min -1 and 0.105-0.210min -1 for water and ethanol/water (1:1, v/v) applied as extractants, respectively. Furthermore, no statistically significant differences were found between the estimated values of bioaccessible antioxidant compounds by the kinetic model and the values attained using conventional batch-wise extraction methodology, ranging from 3.37 to 60.3 µmol of Trolox ((±)-6-hydroxy-2,5,7,8-tetramethylchromane-2-carboxylic acid) per g of sample. Extension of the method using U. S. Pharmacopeia surrogate biological media (stomach (pH 1.2) and intestinal (pH 7.5) fluids without enzymes) to NIST-1570a spinach leaves provided gastrointestinal compartment-dependent kinetic leaching rates (0.120 and 0.198min -1 , respectively) and total antioxidant content (45.5 and 52.5µmol of Trolox per g of sample, respectively). Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Foam Flow Through a 2D Porous Medium: Evolution of the Bubble Size Distribution

    Science.gov (United States)

    Meheust, Y.; Géraud, B.; Cantat, I.; Dollet, B.

    2017-12-01

    Foams have been used for decades as displacing fluids for EOR and aquifer remediation, and more recently as carriers of chemical amendments for remediation of the vadose zone. Bulk foams are shear-thinning fluids; but for foams with bubbles of order at least the typical pore size of the porous medium, the rheology cannot be described at the continuum scale, as viscous dissipation occurs mostly at the contact between soap films and solid walls. We have investigated the flow of an initially monodisperse foam through a transparent 2D porous medium[1]. The resulting complex flow phenomenology has been characterized quantitatively from optical measurements of the bubble dynamics. In addition to preferential flow path and local flow intermittency, we observe an irreversible evolution of the probability density function (PDF) for bubbles size as bubbles travel along the porous medium. This evolution is due to bubble fragmentation by lamella division, which is by far the dominant mechanism of film creation/destruction. We measure and characterize this evolution of the PDF as a function of the experimental parameters, and model it numerically based on a fragmentation equation, with excellent agreement. The model uses two ingredients obtained from the experimental data, namely the statistics of the bubble fragmentation rate and of the fragment size distributions[2]. It predicts a nearly-universal scaling of all PDFs as a function of the bubble area normalized by the initial mean bubble area. All the PDFs measured in various experiments, with different mean flow velocities, initial bubble sizes and foam qualities, collapse on a master distribution which is only dependent on the geometry of the medium.References:[1] B. Géraud, S. A. Jones, I. Cantat, B. Dollet & Y. Méheust (2016), WRR 52(2), 773-790. [2] B. Géraud, Y. Méheust, I. Cantat & B. Dollet (2017), Lamella division in a foam flowing through a two-dimensional porous medium: A model fragmentation process, PRL 118

  14. A flow-through cell with integrated coulometric pH actuator

    NARCIS (Netherlands)

    Bohm, S.; Olthuis, Wouter; Bergveld, Piet

    1998-01-01

    A flow-through cell with integrated coulometric actuator capable of controlling the pH of a flowing liquid is presented. The cell, consisting of a rectangular channel with a noble metal actuator electrode deposited on the bottom, enables the titration of a moving liquid without the need for pumps

  15. Air flow through a non-airconditioned bus with open windows

    Indian Academy of Sciences (India)

    dows; this is the basis of on-road airconditioned buses and the airconditioning equipment is roof mounted. Both the capital cost and running cost are more. Because of this .... potassium permanganate or green/red ink into water. ... Air flow through the roof ventilators that are commonly provided on a bus was also studied.

  16. A flow-through amperometric sensor based on dialysis tubing and free enzyme reactors

    NARCIS (Netherlands)

    Bohm, S.; Pijanowska, D.G.; Pijanowska, D.; Olthuis, Wouter; Bergveld, Piet

    2001-01-01

    A generic flow-through amperometric microenzyme sensor is described, which is based on semi-permeable dialysis tubing carrying the sample to be analyzed. This tubing (300 μm OD) is led through a small cavity, containing the working and reference electrode. By filling this cavity with a few μl of an

  17. A flow-through potentiometric sensor for an integrated microdialysis system

    NARCIS (Netherlands)

    Pijanowska, D.; Pijanowska, D.G.; Sprenkels, A.J.; van der Linden, H.J.; Bergveld, Piet; van den Berg, Albert; Olthuis, Wouter

    2003-01-01

    In this paper, the performance of a flow-through potentiometric sensor based on a semi-permeable dialysis tubing implemented in silicon, is presented. The sensor is designed as part of a lab-on-a-chip system and has been successfully incorporated into an integrated microdialysis system. Results of a

  18. A flow-through potentiometric sensor for an integrated microdialysis system

    NARCIS (Netherlands)

    Pijanowska, D.G.; Sprenkels, A.J.; van der Linden, H.J.; Olthuis, Wouter; Bergveld, Piet; van den Berg, Albert

    2004-01-01

    In this paper, the performance of a flow-through potentiometric sensor based on a semi-permeable dialysis tubing implemented in silicon, is presented. The sensor is designed as part of a lab-on-a-chip system and has been successfully incorporated into an integrated microdialysis system. Results of a

  19. Comparison of Flow-Through Cell and Paddle Methods for Testing ...

    African Journals Online (AJOL)

    HP

    Purpose: To evaluate the usefulness of the flow-through cell apparatus for testing commercial vaginal tablets containing poorly water-soluble clotrimazole. Methods: The effect of experimental conditions (type of dissolution medium, flow rate and positioning of the tablet) on the dissolution profile of clotrimazole were ...

  20. Substance flows through the economy and environment of a region : Part I: Systems definition

    NARCIS (Netherlands)

    Van Der Voet, Ester; Kleijn, René; Van Oers, Lauran; Heijungs, Reinout; Huele, Ruben; Mulder, Paul

    1995-01-01

    In the tradition of the study of materials flows through society, the Substance Flow Analysis (SFA) method is presented. SFA aims at providing the relevant information for a country’s overall management strategy regarding single substances or coherent groups of substances. This article is dedicated

  1. Numerical solution of inviscid transonic flow through 3D axial blade row

    Energy Technology Data Exchange (ETDEWEB)

    Fort, J.; Fuerst, J.; Halama, J.; Kozel, K. [CTU Prague (Czech Republic). Dept. of Technical Mathematics

    2000-07-01

    Presented paper deals with numerical solution of 3D inviscid transonic flow through axial cascades. Two different finite volume methods are mentioned. Authors show a comparison of both methods using results computed for the stator and the rotor cascades. A role of inlet parameters and body forces in the case of a rotor flow has been also investigated. (orig.)

  2. Flow visualization analysis of two-phase flow through contraction using shadow-image and PIV

    International Nuclear Information System (INIS)

    Watanabe, Satoshi; Morimoto, Yuichiro; Ishikawa, Masaaki; Okamoto, Koji; Madarame, Haruki

    2004-01-01

    Gas-liquid two-phase flow through contraction was visualized and analyzed using shadow-image and PIV. The flow channel has reducer, where the width was contracted from 50mm to 20mm. Bubble deformation and concurrent velocity fluctuation was investigated varying superficial liquid flow rate from 0.4m/s to 8.0m/s. (author)

  3. Wear resistance studies of an austempered ductile iron with the aid of a single pass grooving pendulum; Estudo do comportamento em desgate de um ferro fundido nodular austemperado atraves da tecnica da tecnica de esclerometria pendular

    Energy Technology Data Exchange (ETDEWEB)

    Velez, J.M.; Tschiptschin, A.P. [Sao Paulo Univ., SP (Brazil). Escola Politecnica

    1995-12-31

    The abrasive wear resistance of an austempered ductile iron was studied with the aid of a single pass grooving pendulum. Specimens were austenitized at 860 deg C and austempered at 370 deg C for 30, 60, 90, 180 and 240 min. Austenite transformation kinetics was measured by quantitative metallography. Specimens for pendulum tests were gridded as squared based prisms (50 mm x 10 mm x 10 mm) and one of the faces submitted to metallographic polishing before the test. A hard metal cutting tool was used as abrasive. The absorbed energy as well as the loss of matter were measured. Scanning Electron Microscopy was used to analyze the surface topography of the scratched specimen. It was observed a maximum in the absorbed specific energy for the specimen treated for 60 min. with a microstructure of bainite ferrite plus plus 42% volume fraction of retained austenite. All other structures (ferrite plus carbides, ferrite plus lower contents of austenite and martensite plus austenite) gave lower values of absorbed specific energy. Observation of scratches and chips formed on the surface of the specimen can explain the above mentioned behaviour 12 refs., 11 figs., 2 tabs.

  4. The effect of food on the respiration rates of Daphnia magna using a flow-through system

    Directory of Open Access Journals (Sweden)

    Claire Schmoker

    2003-09-01

    Full Text Available Respiration rates and gut fluorescence of the cladoceran Daphnia magna were studied using a flow-through system. This open system has the advantage of introducing food or producing a starvation effect during the course of the experiment. Severe variations in respiratory rates were observed in relation to the presence or absence of food, indicating short-term variability. Organisms kept starved or at low food for a long period (15-20 h responded to a sudden increase in food by increasing their respiration rates three- to four-fold in parallel with their gut content. A significant relationship between gut fluorescence and respiration rates was observed, suggesting that feeding and the related swimming activity were responsible for the observed metabolic variability.

  5. Dissolution kinetics of UO2: Flow-through tests on UO2.00 pellets and polycrystalline schoepite samples in oxygenated, carbonate/bicarbonate buffer solutions at 25 degree C

    International Nuclear Information System (INIS)

    Nguyen, S.N.; Weed, H.C.; Leider, H.R.; Stout, R.B.

    1991-10-01

    The modelling of radionuclide release from waste forms is an important part of the performance assessment of a potential, high-level radioactive waste repository. Since spent fuel consists of UO 2 containing actinide elements and other fission products, it is necessary to determine the principal parameters affecting UO 2 dissolution and quantify their effects on the dissolution rate before any prediction of long term release rates of radionuclides from the spent fuel can be made. As part of a complex matrix to determine the dissolution kinetics of UO 2 as a function of time, pH, carbonate/bicarbonate concentration and oxygen activity, we have measured the dissolution rates at 25 degrees C of: (1) UO 2 pellets; (2) UO 2.00 powder and (3) synthetic dehydrated schoepite, UO 3 .H 2 O using a single-pass flow through system in an argon-atmosphere glove box. Carbonate, carbonate/bicarbonate, and bicarbonate buffers with concentrations ranging from 0.0002 M to 0.02 M and pH values form 8 to 11 have been used. Argon gas mixtures containing oxygen (from 0.002 to 0.2 atm) and carbon dioxide (from 0 to 0.011 atm) were bubbled through the buffers to stabilize their pH values. 12 refs., 2 tabs

  6. Heating in vascular tissue and flow-through tissue phantoms induced by focused ultrasound

    Science.gov (United States)

    Huang, Jinlan

    High intensity focused ultrasound (HIFU) can be used to control bleeding, both from individual blood vessels as well as from gross damage to the capillary bed. This process, called acoustic hemostasis, is being studied in the hope that such a method would ultimately provide a lifesaving treatment during the so-called "golden hour", a brief grace period after a severe trauma in which prompt therapy can save the life of an injured person. Thermal effects play a major role in occlusion of small vessels and also appear to contribute to the sealing of punctures in major blood vessels. However, aggressive ultrasound-induced tissue heating can also impact healthy tissue and can lead to deleterious mechanical bioeffects. Moreover, the presence of vascularity can limit one's ability to elevate the temperature of blood vessel walls owing to convective heat transport. In an effort to better understand the heating process in tissues with vascular structure we have developed a numerical simulation that couples models for ultrasound propagation, acoustic streaming, ultrasound heating and blood cooling in Newtonian viscous media. The 3-D simulation allows for the study of complicated biological structures and insonation geometries. We have also undertaken a series of in vitro experiments, in non-uniform flow-through tissue phantoms, designed to provide a ground truth verification of the model predictions. The calculated and measured results were compared over a range of values for insonation pressure, insonation time, and flow rate; we show good agreement between predictions and measurements. We then conducted a series of simulations that address two limiting problems of interest: hemostasis in small and large vessels. We employed realistic human tissue properties and considered more complex geometries. Results show that the heating pattern in and around a blood vessel is different for different vessel sizes, flow rates and for varying beam orientations relative to the flow axis

  7. Performance comparison of the commercial CFD software for the prediction of turbulent flow through tube bundles

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Gong Hee; Bang, Young Seok; Woo, Sweng Woong [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2012-10-15

    Because turbulent flow through tube bundles can be found in many important industrial applications, such as PWR reactor, steam generator, CANDU calandria and lower plenum of the VHTR, extensive studies have been made both experimentally and numerically. Although recently licensing applications supported by commercial CFD software are increasing, there is no commercial CFD software which obtains a licensing from the regulatory body until now. Therefore, it is necessary to perform the systematic assessment for the prediction performance of the commercial CFD software. The main objective of the present study is to numerically simulate turbulent flow through both staggered and in line tube bundle using the two popular commercial CFD software, ANSYS CFX and FLUENT and to compare the simulation results with the experimental data for the assessment of these software's prediction performance.

  8. A flow-through hydrothermal cell for in situ neutron diffraction studies of phase transformations

    International Nuclear Information System (INIS)

    O'Neill, Brian; Tenailleau, Christophe; Nogthai, Yung; Studer, Andrew; Brugger, Joel; Pring, Allan

    2006-01-01

    A flow-through hydrothermal cell for the in situ neutron diffraction study of crystallisation and phase transitions has been developed. It can be used for kinetic studies on materials that exhibit structural transformations under hydrothermal conditions. It is specifically designed for use on the medium-resolution powder diffractometer (MRPD) at ANSTO, Lucas Heights, Sydney. But it is planned to adapt the design for the Polaris beamline at ISIS and the new high-intensity powder diffractometer (Wombat) at the new Australian reactor Opal. The cell will operate in a flow-through mode over the temperature range from 25-300 deg. C and up to pressures of 100 bar. The first results of a successful transformation of pentlandite (Fe,Ni) 9 S 8 to violarite (Fe,Ni) 3 S 4 under mild conditions (pH∼4) at 120 deg. C and 3 bar using in situ neutron diffraction measurements are presented

  9. Development of a micro flow-through cell for high field NMR spectroscopy.

    Energy Technology Data Exchange (ETDEWEB)

    Alam, Todd Michael; McIntyre, Sarah K.

    2011-05-01

    A highly transportable micro flow-through detection cell for nuclear magnetic resonance (NMR) spectroscopy has been designed, fabricated and tested. This flow-through cell allows for the direct coupling between liquid chromatography (LC) and gel permeation chromatography (GPC) resulting in the possibility of hyphenated LC-NMR and GPC-NMR. The advantage of the present flow cell design is that it is independent and unconnected to the detection probe electronics, is compatible with existing commercial high resolution NMR probes, and as such can be easily implemented at any NMR facility. Two different volumes were fabricated corresponding to between {approx}3.8 and 10 {micro}L detection volume. Examples of the performance of the cell on different NMR instruments, and using different NMR detection probes were demonstrated.

  10. Development of a flow-through system to create occluding thrombus.

    Science.gov (United States)

    Ku, David N; Flannery, Conor J

    2007-01-01

    Occlusive thrombosis accounts for many heart attacks and strokes. These acute events are difficult to catch in patients and animal test methods may be misleading because anti-thrombotic therapeutics often do not cross-react with different species. This paper presents a new flow-through system that leads to rapid occlusive thrombosis in arterial flow conditions. Whole porcine blood is perfused through a tubular test section. The growing thrombus is visualized in real time from early platelet attachment, through accumulation, to occlusion. The progression of flow rate reduction provides a clear distinguishing parameter between thrombus formation and embolization. Thrombus growth rate is a linear function of very high shear rate beyond 40,000 s(-1). The histology of the thrombus reveals predominantly platelet accumulation and growth as a rough surface with tendrils. This flow-through system may be useful for the economic testing of new anti-thrombosis therapies.

  11. How Important Is Connectivity for Surface Water Fluxes? A Generalized Expression for Flow Through Heterogeneous Landscapes

    Science.gov (United States)

    Larsen, Laurel G.; Ma, Jie; Kaplan, David

    2017-10-01

    How important is hydrologic connectivity for surface water fluxes through heterogeneous floodplains, deltas, and wetlands? While significant for management, this question remains poorly addressed. Here we adopt spatial resistance averaging, based on channel and patch configuration metrics quantifiable from aerial imagery, to produce an upscaled rate law for discharge. Our model suggests that patch coverage largely controls discharge sensitivity, with smaller effects from channel connectivity and vegetation patch fractal dimension. However, connectivity and patch configuration become increasingly important near the percolation threshold and at low water levels. These effects can establish positive feedbacks responsible for substantial flow change in evolving landscapes (14-36%, in our Everglades case study). Connectivity also interacts with other drivers; flow through poorly connected hydroscapes is less resilient to perturbations in other drivers. Finally, we found that flow through heterogeneous patches is alone sufficient to produce non-Manning flow-depth relationships commonly observed in wetlands but previously attributed to depth-varying roughness.

  12. Assessment of the biodegradability of dialkyldimethylammonium salts in flow through systems.

    Science.gov (United States)

    van Ginkel, C G; Hoenderboom, A; van Haperen, A M; Geurts, M G J

    2003-09-01

    A bacterium capable of utilizing the alkyl chains of didecyldimethylammonium salt was isolated from activated sludge. In addition, the isolate also utilized didodecyldimethylammonium salt, ditetradecyldimethylammonium salt and alkyltrimethylammonium salts (C10 to C18) as sole source of carbon and energy. The broad substrate with respect to the alkyl chain length was also demonstrated with oxidation rates of various quaternary ammonium salts by didecyldimethylammonium chloride-grown cells. The oxidation rate decreased with increasing alkyl chain lengths. The main factor impeding the biodegradation of dialkyldimethylammonium salts with long alkyl chains is probably the low bioavailability of water-insoluble chemicals. The biodegradability of dialkyldimethylammonium salts was therefore determined in flow-through columns at concentrations below their aqueous solubility. Dialkyldimethylammonium salts adsorbed on silica gel particles packed in flow-through columns were immediately metabolized by the isolate when dissolved. Microorganisms present in river water pumped through a sterile column degraded dissolved dicocodimethylammonium salts within a week.

  13. Simulation of the Flow Through Porous Layers Composed of Converging-Diverging Capillary Fissures or Tubes

    Science.gov (United States)

    Walicka, A.

    2018-02-01

    In this paper, a porous medium is modelled by a network of converging-diverging capillaries which may be considered as fissures or tubes. This model makes it necessary to consider flows through capillary fissures or tubes. Therefore an analytical method for deriving the relationships between pressure drops, volumetric flow rates and velocities for the following fluids: Newtonian, polar, power-law, pseudoplastic (DeHaven and Sisko types) and Shulmanian, was developed. Next, considerations on the models of pore network for Newtonian and non-Newtonian fluids were presented. The models, similar to the schemes of central finite differences may provide a good basis for transforming the governing equations of a flow through the porous medium into a set of linear or quasi-linear algebraic equations. It was shown that the some coefficients in these algebraic equations depend on the kind of the capillary convergence.

  14. A study on rarefied gas flows through in-line arrangements of cylinders

    OpenAIRE

    田口, 智清; Satoshi, Taguchi; 神大・研究環; Kobe University

    2007-01-01

    Rarefied gas flows through in-line arrangements of cylinders are considered on the basis of the Boltzmann equation employing the BGK collision operator for the gas phase and the heat-conduction equation for the temperature inside the cylinders. Under the condition where the size of the periodic unit cell is much smaller than the characteristic length of the global structure, a diffusion model describing the mass and heat transfer through the medium is obtained by homogenization in the case wh...

  15. Finite Element Prediction of Multi-Size Particulate Flow through Three-Dimensional Channel: Code Validation

    OpenAIRE

    K. V. Pagalthivarthi; R. J. Visintainer

    2013-01-01

    Multi-size particulate dense slurry flow through three-dimensional rectangular channel is modeled using penalty finite elements with 8-noded hexahedral elements. The methodology previously developed for two-dimensional channel is extended. The computed eddy viscosity of the pure carrier flow is modified to account for the presence of solid particles. Predictions from Spalart-Almaras and k-ε turbulence models are compared to show consistency of trends in results. Results are also found to comp...

  16. Experimental investigation of lateral forces induced by flow through model labyrinth glands

    Science.gov (United States)

    Leong, Y. M. M. S.; Brown, R. D.

    1984-01-01

    The lateral forces induced by flow through model labyrinth glands were investigated. Circumferential pressure distributions, lateral forces and stiffness coefficients data obtained are discussed. The force system is represented as a negative spring and a tangential force orthogonal to eccentricity. The magnitude of these forces are dependent on eccentricity, entry swirl, rotor peripheral velocity and seal size. A pressure equalization chamber at midgland tests should in significantly reduced forces and stiffness coefficients.

  17. Influence of flow-through and renewal exposures on the toxicity of copper to rainbow trout

    Science.gov (United States)

    Welsh, P.G.; Lipton, J.; Mebane, C.A.; Marr, J.C.A.

    2008-01-01

    We examined changes in water chemistry and copper (Cu) toxicity in three paired renewal and flow-through acute bioassays with rainbow trout (Oncorhynchus mykiss). Test exposure methodology influenced both exposure water chemistry and measured Cu toxicity. Ammonia and organic carbon concentrations were higher and the fraction of dissolved Cu lower in renewal tests than in paired flow-through tests. Cu toxicity was also lower in renewal tests; 96 h dissolved Cu LC50 values were 7-60% higher than LC50s from matching flow-through tests. LC50 values in both types of tests were related to dissolved organic carbon (DOC) concentrations in exposure tanks. Increases in organic carbon concentrations in renewal tests were associated with reduced Cu toxicity, likely as a result of the lower bioavailability of Cu-organic carbon complexes. The biotic ligand model of acute Cu toxicity tended to underpredict toxicity in the presence of DOC. Model fits between predicted and observed toxicity were improved by assuming that only 50% of the measured DOC was reactive, and that this reactive fraction was present as fulvic acid. ?? 2007 Elsevier Inc. All rights reserved.

  18. Experimental investigations of the steady flow through an idealized model of a femoral artery bypass

    Directory of Open Access Journals (Sweden)

    Giurgea Corina

    2014-03-01

    Full Text Available The present paper presents the steps taken by the authors in the first stage of an experimental program within a larger national research project whose objective is to characterize the flow through a femoral artery bypass with a view to finding solutions for its optimization. The objective of the stage is to investigate by means of the PIV method the stationary flow through a bypass model with an idealized geometry. A bypass assembly which reunites the idealized geometry models of the proximal and distal anastomoses, and which respects the lengths of a femoral artery bypass was constructed on the basis of data for a real patient provided by medical investigations. With the aim of testing the model and the established experimental set-up with regard to their suitability for the assessment of the velocity field associated to the steady flow through the bypass, three zones that can restore the whole distal anastomosis were PIV investigated. The measurements were taken in the conditions of maintained inflow at the bypass entry of 0.9 l / min (Re = 600. The article presents comparatively the flow spectra and the velocity fields for each zone obtained in two situations: with the femoral artery completely occluded and completely open.

  19. Permeameter studies of water flow through cement and clay borehole seals in granite, basalt and tuff

    Energy Technology Data Exchange (ETDEWEB)

    South, D.L.; Daemen, J.J.K.

    1986-10-01

    Boreholes near a repository must be sealed to prevent rapid migration of radionuclide-contaminated water to the accessible environment. The objective of this research is to assess the performance of borehole seals under laboratory conditions, particularly with regard to varying stress fields. Flow through a sealed borehole is compared with flow through intact rock. Cement or bentonite seals have been tested in granite, basalt, and welded tuff. The main conclusion is that under laboratory conditions, existing commercial materials can form high quality seals. Triaxial stress changes about a borehole do not significantly affect seal performance if the rock is stiffer than the seal. Temperature but especially moisture variations (drying) significantly degrade the quality of cement seals. Performance partially recovers upon resaturation. A skillfully sealed borehole may be as impermeable as the host rock. Analysis of the influence of relative seal-rock permeabilities shows that a plug with permeability one order of magnitude greater than that of the rock results in a flow increase through the hole and surrounding rock of only 1-1/2 times compared to the undisturbed rock. Since a borehole is only a small part of the total rock mass, the total effect is even less pronounced. The simplest and most effective way to decrease flow through a rock-seal system is to increase the seal length, assuming it can be guaranteed that no dominant by-pass flowpath through the rock exists.

  20. Early Mobilization after Free-flap Transfer to the Lower Extremities: Preferential Use of Flow-through Anastomosis

    Directory of Open Access Journals (Sweden)

    Shimpei Miyamoto, MD

    2014-03-01

    Conclusions: This study demonstrates that early mobilization after free-flap transfer to the lower extremity is made possible by flow-through anastomosis for both arteries and veins. Flow-through flaps have stable circulation from the acute phase and can tolerate early dangling and ambulation.

  1. Design of an electronically operated flow-through respirometer and its use to investigate the effects of copper on the respiration rate of the amphipod gammarus pulex (L.)

    Energy Technology Data Exchange (ETDEWEB)

    Kedwards, J.T.; Blockwell, S.J.; Tylor, E.J.; Pascoe, T.D. [Univ. of Wales College of Cardiff (United Kingdom)

    1996-12-31

    The use of oxygen consumption as a measure of metabolism has resulted in the development of many types of respirometer. These can be classified into three types. Firstly, there is the closed system in which oxygen concentration is measured at the beginning and end of the experiment and an organism`s respiratory rate calculated from the decrease in oxygen concentration and the volume of the vessel. Secondly, there is a system in which respired oxygen is replaced by oxygen from the surrounding air and the resultant change in air volume is measured gasometrically. A third approach, and the one employed in this study, utilises an open flow-through system in which water passes through a chamber containing an animal and the oxygen concentration is measured and compared to that of a reference chamber without an animal. The difference in oxygen concentration is then used to determine the respiration rate of the test animal. In open flow-through systems excretory products are washed away and water is not left stagnant as may occur in closed techniques. In addition, the open flow technique provides a constant oxygen concentration, avoids stress to animals with oxygen concentration-dependent metabolism and allows the simulation of low oxygen tension environments. Despite these obvious advantages the use of flow-through respirometers has been somewhat limited due to difficulties in calibration and complexity in construction and operation (Edwards and Learner 1960). The purpose of this investigation was to design a flow-through respirometer which is sufficiently sensitive to detect pollutant-induced respiratory changes in freshwater invertebrates and which permits automated continuous recording of the respiration of several animals maintained individually. In order to evaluate the system the effect of copper (prepared form cupric sulphate, CuSO{sub 4}.5H{sub 2}O) on the respiration of the shrimp Gammarus pulex was studied. 26 refs., 2 figs., 1 tab.

  2. Investigation into Behavior of a Steam-Water Mixture Flow Through Holes in a Submerged Perforated Sheet at High Void Fractions

    Science.gov (United States)

    Melikhov, V. I.; Melikhov, O. I.; Nerovnov, A. A.; Nikonov, S. M.

    2018-01-01

    Processing of experimental data on the pressure difference across a submerged perforated sheet (SPS) revealed that, at sufficiently high void fractions under SPS, the pressure difference across it became less than the pressure difference for the pure steam stream with the same flowrate. To find the cause of this, the effect of a liquid film, which can be formed on the SPS upstream surface as a result of water droplets' impact and can smooth over sharp edges of holes in SDS, was examined. This can decrease the pressure drop across the sharp edges of holes. This assumption was checked through numerical solution to several model problems in the axisymmetric formulation for a steam flow in a round pipe with an orifice. The flow of steam and water was modeled using the viscous incompressible liquid approximation, while the turbulence was described by the k-ɛ model. The evolution of the interfacial area was modeled using the VOF model. The following model problems of steam flow through an orifice were studied: a single-phase flow, a flow through the orifice with a liquid film on its upstream surface, a flow through a chamfered hole, and a flow through the orifice with a liquid film on its upstream surface without liquid supply to the film. The predictions demonstrate that even the approximate account of the liquid film effect on the steam flow yields a considerable decrease in the pressure drop across the hole (from 8 to 24%) due to smoothing its sharp outlet edges over. This makes it possible to make a conclusion that the cause of a decrease in the pressure drop across SPS observed in the experiments at high void fractions is the formation of a liquid film, which smooths the sharp edges of the hole.

  3. A scalable variational inequality approach for flow through porous media models with pressure-dependent viscosity

    Science.gov (United States)

    Mapakshi, N. K.; Chang, J.; Nakshatrala, K. B.

    2018-04-01

    Mathematical models for flow through porous media typically enjoy the so-called maximum principles, which place bounds on the pressure field. It is highly desirable to preserve these bounds on the pressure field in predictive numerical simulations, that is, one needs to satisfy discrete maximum principles (DMP). Unfortunately, many of the existing formulations for flow through porous media models do not satisfy DMP. This paper presents a robust, scalable numerical formulation based on variational inequalities (VI), to model non-linear flows through heterogeneous, anisotropic porous media without violating DMP. VI is an optimization technique that places bounds on the numerical solutions of partial differential equations. To crystallize the ideas, a modification to Darcy equations by taking into account pressure-dependent viscosity will be discretized using the lowest-order Raviart-Thomas (RT0) and Variational Multi-scale (VMS) finite element formulations. It will be shown that these formulations violate DMP, and, in fact, these violations increase with an increase in anisotropy. It will be shown that the proposed VI-based formulation provides a viable route to enforce DMP. Moreover, it will be shown that the proposed formulation is scalable, and can work with any numerical discretization and weak form. A series of numerical benchmark problems are solved to demonstrate the effects of heterogeneity, anisotropy and non-linearity on DMP violations under the two chosen formulations (RT0 and VMS), and that of non-linearity on solver convergence for the proposed VI-based formulation. Parallel scalability on modern computational platforms will be illustrated through strong-scaling studies, which will prove the efficiency of the proposed formulation in a parallel setting. Algorithmic scalability as the problem size is scaled up will be demonstrated through novel static-scaling studies. The performed static-scaling studies can serve as a guide for users to be able to select

  4. Investor Behavior and Flow-through Capability in the US Stock Market.

    Science.gov (United States)

    Cano, Carlos; Jareño, Francisco; Tolentino, Marta

    2016-01-01

    This paper analyzes investor behavior depending on the flow-through capability (FTC) in the US stock market, because investors seek protection from inflation rate changes, and the FTC (a firm's ability to transmit inflation shocks to the prices of its products and services) is a key factor in investment decisions. Our estimates of the FTC of firms listed on the US stock exchange at the sector level are significantly different among industries, and we demonstrate a direct relationship between changes in stock prices (at the sector level) and FTC. These results would be relevant because they have important implications on investor behavior.

  5. A highly energy-efficient flow-through electro-Fenton process for organic pollutants degradation

    International Nuclear Information System (INIS)

    Ma, Liang; Zhou, Minghua; Ren, Gengbo; Yang, Weilu; Liang, Liang

    2016-01-01

    Highlights: • A highly energy-efficient flow-through electro-Fenton reactor was designed. • It had high H 2 O 2 yield and low energy consumption for organic pollutants degradation. • The effect of operational parameters was optimized and possible process mechanism was studied. • The novel system performed wide practicability and potential for organic pollutants degradation. - Abstract: A highly energy-efficient flow-through Electro-Fenton (E-Fenton) reactor for oxidation of methylene blue (MB) from aqueous solution was designed using a perforated DSA as anode and the graphite felt modified by carbon black and polytetrafluoroethylene (PTFE) as cathode for the in situ generation of H 2 O 2 . The modified cathode had a high H 2 O 2 production with low energy consumption, which was characterized by scanning electron microscopy (SEM), nitrogen adsorption-desorption study and contact angle. The flow-through E-Fenton system was compared to the flow-by and regular one, and confirmed to be best on MB removal and TOC degradation. The operational parameters such as current density, pH, Fe 2+ concentration and flow rate were optimized. The MB and TOC removal efficiency of the effluents could keep above 90% and 50%, respectively, and the energy consumption was 23.0 kWh/kgTOC at the current density of 50 mA, pH 3, 0.3 mM Fe 2+ , and the flow rate of 7 mL/min. ·OH was proved to be the main oxidizing species in this system. After 5 times operation, the system, especially cathode, still showed good stability. Five more organic pollutants including orange II (OG), tartrazine, acetylsalicylic acid (ASA), tetracycline (TC) and 2,4-dichlorophen (2,4-DCP) were investigated and the electric energy consumption (EEC) was compared with literatures. All results demonstrated that this flow-through E-Fenton system was energy-efficient and potential for degradation of organic pollutants.

  6. Finite Element Prediction of Multi-Size Particulate Flow through Three-Dimensional Channel: Code Validation

    Directory of Open Access Journals (Sweden)

    K. V. Pagalthivarthi

    2013-03-01

    Full Text Available Multi-size particulate dense slurry flow through three-dimensional rectangular channel is modeled using penalty finite elements with 8-noded hexahedral elements. The methodology previously developed for two-dimensional channel is extended. The computed eddy viscosity of the pure carrier flow is modified to account for the presence of solid particles. Predictions from Spalart-Almaras and k-ε turbulence models are compared to show consistency of trends in results. Results are also found to compare well with experimental results from the literature.

  7. Investor Behavior and Flow-through Capability in the US Stock Market

    Science.gov (United States)

    Cano, Carlos; Jareño, Francisco; Tolentino, Marta

    2016-01-01

    This paper analyzes investor behavior depending on the flow-through capability (FTC) in the US stock market, because investors seek protection from inflation rate changes, and the FTC (a firm's ability to transmit inflation shocks to the prices of its products and services) is a key factor in investment decisions. Our estimates of the FTC of firms listed on the US stock exchange at the sector level are significantly different among industries, and we demonstrate a direct relationship between changes in stock prices (at the sector level) and FTC. These results would be relevant because they have important implications on investor behavior. PMID:27242585

  8. Numerical Investigation of Oxygenated and Deoxygenated Blood Flow through a Tapered Stenosed Arteries in Magnetic Field.

    Directory of Open Access Journals (Sweden)

    M Y Abdollahzadeh Jamalabadi

    Full Text Available Current paper is focused on transient modeling of blood flow through a tapered stenosed arteries surrounded a by solenoid under the presence of heat transfer. The oxygenated and deoxygenated blood are considered here by the Newtonian and Non-Newtonian fluid (power law and Carreau-Yasuda models. The governing equations of bio magnetic fluid flow for an incompressible, laminar, homogeneous, non-Newtonian are solved by finite volume method with SIMPLE algorithm for structured grid. Both magnetization and electric current source terms are well thought-out in momentum and energy equations. The effects of fluid viscosity model, Hartmann number, and magnetic number on wall shear stress, shearing stress at the stenosis throat and maximum temperature of the system are investigated and are optimized. The current study results are in agreement with some of the existing findings in the literature and are useful in thermal and mechanical design of spatially varying magnets to control the drug delivery and biomagnetic fluid flows through tapered arteries.

  9. Computed tomography for the quantitative characterization of flow through a porous medium

    International Nuclear Information System (INIS)

    Auzerais, F.M.; Dussan, E.B.; Reischer, A.J.

    1991-01-01

    X-ray computer tomography (CT) has become an increasingly popular research tool in petroleum engineering for characterizing porous media. Its highly detailed images have been used to construct maps of porosity, saturation and atomic composition, and to visualize the displacement of fluids. However, extracting data necessary to characterize flow through porous media is both time consuming and dependent on the availability of extensive computational resources - - a consequence of the large size of the image files. The authors of this paper applied to known technique, based upon the ability to recognize regions with similar features, which avoids these difficulties. It allows the authors to substitute for the image, the pixel location of the boundaries of the recognized regions, reducing considerably the computer storage requirements. The authors this technique to study the dynamics of two miscible liquids of different densities flowing through a porous medium where buoyancy plays an important role. The authors' specific concern is the movement of mud filtrate as it penetrates a permeable formation in the vicinity of a recently drilled wellbore. The authors quantify the manner in which impermeable horizontal barriers influence the movement of the filtrate

  10. Flow-Through Stream Modeling with MODFLOW and MT3D: Certainties and Limitations.

    Science.gov (United States)

    Ben Simon, Rose; Bernard, Stéphane; Meurville, Charles; Rebour, Vincent

    2015-01-01

    This paper aims to assess MODFLOW and MT3D capabilities for simulating the spread of contaminants from a river exhibiting an unusual relationship with an alluvial aquifer, with the groundwater head higher than the river head on one side and lower on the other (flow-through stream). A series of simulation tests is conducted using a simple hypothetical model so as to characterize and quantify these limitations. Simulation results show that the expected contaminant spread could be achieved with a specific configuration composed of two sets of parameters: (1) modeled object parameters (hydraulic groundwater gradient, hydraulic conductivity values of aquifer and streambed), and (2) modeling parameters (vertical discretization of aquifer, horizontal refinement of stream modeled with River [RIV] package). The influence of these various parameters on simulation results is investigated, and potential complications and errors are identified. Contaminant spread from stream to aquifer is not always reproduced by MT3D due to the RIV package's inability to simulate lateral exchange fluxes between stream and aquifer. This paper identifies the need for a MODFLOW streamflow package allowing lateral stream-aquifer interactions and streamflow routine calculations. Such developments could be of particular interest for modeling contaminated flow-through streams. © 2015, National Ground Water Association.

  11. A flow-through hydrothermal cell for in situ neutron diffraction studies of phase transformations

    Energy Technology Data Exchange (ETDEWEB)

    O' Neill, Brian [School of Chemical Engineering, The University of Adelaide, South Australia 5005 (Australia); Tenailleau, Christophe [Department of Mineralogy, South Australian Museum, North Terrace, Adelaide, South Australia 5000 (Australia); Nogthai, Yung [School of Chemical Engineering, The University of Adelaide, South Australia 5005 (Australia); Studer, Andrew [Bragg Institute, ANSTO, PMB 1 Menai, New South Wales 2234 (Australia); Brugger, Joel [Department of Mineralogy, South Australian Museum, North Terrace, Adelaide, South Australia 5000 (Australia): Department of Geology and Geophysics, The University of Adelaide, North Terrace, Adelaide, South Australia 5005 (Australia); Pring, Allan [Department of Mineralogy, South Australian Museum, North Terrace, Adelaide, South Australia 5000 (Australia): Department of Geology and Geophysics, The University of Adelaide, North Terrace, Adelaide, South Australia 5005 (Australia)]. E-mail: pring.allan@saugov.sa.gov.au

    2006-11-15

    A flow-through hydrothermal cell for the in situ neutron diffraction study of crystallisation and phase transitions has been developed. It can be used for kinetic studies on materials that exhibit structural transformations under hydrothermal conditions. It is specifically designed for use on the medium-resolution powder diffractometer (MRPD) at ANSTO, Lucas Heights, Sydney. But it is planned to adapt the design for the Polaris beamline at ISIS and the new high-intensity powder diffractometer (Wombat) at the new Australian reactor Opal. The cell will operate in a flow-through mode over the temperature range from 25-300 deg. C and up to pressures of 100 bar. The first results of a successful transformation of pentlandite (Fe,Ni){sub 9}S{sub 8} to violarite (Fe,Ni){sub 3}S{sub 4} under mild conditions (pH{approx}4) at 120 deg. C and 3 bar using in situ neutron diffraction measurements are presented.

  12. The Design and Construction of Flow-through Hydrothermal Cells for in situ Neutron Diffraction

    International Nuclear Information System (INIS)

    Pring, A.; Tenailleau, C.; Wang, H.; Brugger, J.; Ngothai, Yung; ONeill, B.

    2005-01-01

    Full text: A flow-through hydrothermal cell for the in-situ neutron diffraction study of hydrothermal crystallisation and phase transitions has been developed. It can be used for kinetic studies on materials that exhibit structural transformations under hydrothermal conditions. New fundamental knowledge on the mechanisms of phase transitions can thus be determined. It is specifically designed for the use on the Medium Resolution Powder Diffractometer at ANSTO, Lucas Heights, Sydney. But it is planned to adapt the design for the new High intensity powder diffractometer (Wombat) at the new Australian reactor Opal. The equipment has been initially created for the low temperature transformation study of Fe-Ni sulfide minerals. The design and use of the flow-through hydrothermal cell from 25 to 120degC are described. The first results of a successful transformation of pentlandite to violarite under mild conditions (pH 4) at 120degC and 3 bars using in-situ neutron diffraction measurements are presented. (authors)

  13. The Design and Construction of Flow-through Hydrothermal Cells for in situ Neutron Diffraction

    International Nuclear Information System (INIS)

    Pring, A.; Tenailleau, C.; Wang, H.; Brugger, J.; Ngothai, Yung; ONeill, B.

    2005-01-01

    Full text: A flow-through hydrothermal cell for the in-situ neutron diffraction study of hydrothermal crystallisation and phase transitions has been developed. It can be used for kinetic studies on materials that exhibit structural transformations under hydrothermal conditions. New fundamental knowledge on the mechanisms of phase transitions can thus be determined. It is specifically designed for the use on the Medium Resolution Powder Diffractometer at ANSTO, Lucas Heights, Sydney. But it is planned to adapt the design for the new High intensity powder diffractometer (Wombat) at the new Australian reactor Opal. The equipment has been initially created for the low temperature transformation study of Fe-Ni sulfide minerals. The design and use of the flow-through hydrothermal cell from 25 to 120 deg C are described. The first results of a successful transformation of pentlandite to violarite under mild conditions (pH 4) at 120 deg C and 3 bars using in-situ neutron diffraction measurements are presented. (authors)

  14. An optofluidic metasurface for lateral flow-through detection of breast cancer biomarker.

    Science.gov (United States)

    Wang, Yifei; Ali, Md Azahar; Chow, Edmond K C; Dong, Liang; Lu, Meng

    2018-02-17

    The rapid growth of point-of-care tests demands for biosensors with high sensitivity and small size. This paper demonstrates an optofluidic metasurface that combines silicon-on-insulator (SOI) nanophotonics and nanofluidics to realize a high-performance, lateral flow-through biosensor. The metasurface is made of a periodic array of silicon nanoposts on an SOI substrate, and functionalized with specific receptor molecules. Bonding of a polydimethylsiloxane slab directly onto the surface results in an ultracompact biosensor, where analyte solutions are restricted to flow only in the space between the nanoposts. No flow exists above the nanoposts. This sensor design overcomes the issue with diffusion-limited detection of many other biosensors. The lateral flow-through feature, in conjunction with high-Q resonance modes associated with optical bound states of the metasurface, offers an improved sensitivity to subtle molecule-bonding induced changes in refractive index. The device exhibits a resonance mode around 1550 nm wavelength and provides an index sensitivity of 720 nm/RIU. Biosensing is conducted to detect the epidermal growth factor receptor 2 (ErbB2), a protein biomarker for early-stage breast cancer screening, by monitoring resonance wavelength shifts in response to specific analyte-ligand binding events at the metasurface. The limit of detection of the device is 0.7 ng mL -1 for ErbB2. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Temperature Prediction for High Pressure High Temperature Condensate Gas Flow Through Chokes

    Directory of Open Access Journals (Sweden)

    Changjun Li

    2012-03-01

    Full Text Available This study developed a theoretical model for predicting the downstream temperatures of high pressure high temperature condensate gas flowing through chokes. The model is composed of three parts: the iso-enthalpy choke model derived from continuity equation and energy conservation equation; the liquid-vapor equilibrium model based on the SRK equation of state (EoS; and the enthalpy model based on the Lee-Kesler EoS. Pseudocritical properties of mixtures, which are obtained by mixing rules, are very important in the enthalpy model, so the Lee-Kesler, Plocker-Knapp, Wong-Sandler and Prausnitz-Gunn mixing rules were all researched, and the combination mixing rules with satisfactory accuracy for high pressure high temperature condensate gases were proposed. The temperature prediction model is valid for both the critical and subcritical flows through different kinds of choke valves. The applications show the model is reliable for predicting the downstream temperatures of condensate gases with upstream pressures up to 85.54 MPa and temperatures up to 93.23 °C. The average absolute errors between the measured and calculated temperatures are expected for less than 2 °C by using the model.

  16. Study of Absorption Characteristics of the Total Saponins from Radix Ilicis Pubescentis in an In Situ Single-Pass Intestinal Perfusion (SPIP Rat Model by Using Ultra Performance Liquid Chromatography (UPLC

    Directory of Open Access Journals (Sweden)

    Guojun Kuang

    2017-11-01

    Full Text Available In contrast to the extensively reported therapeutic activities, far less attention has been paid to the intestinal absorption of the total saponins from Radix Ilicis Pubescentis (in Chinese Mao-Dong-Qing, MDQ. This study aimed to investigate the intestinal absorption characteristics of ilexgenin A (C1, ilexsaponin A1 (C2, ilexsaponin B1 (C3, ilexsaponin B2 (C4, ilexsaponin B3 (DC1, and ilexoside O (DC2 when administrated with the total saponins from MDQ (MDQ-TS. An UPLC method for simultaneous determination of C1, C2, C3, C4, DC1, and DC2 in intestinal outflow perfusate was developed and validated. The absorption characteristics of MDQ-TS were investigated by evaluating the effects of intestinal segments, drug concentration, P-glycoprotein (P-gp inhibitor (verapomil, endocytosis inhibitor (amantadine and ethylene diamine tetraacetic acid (EDTA, tight junction modulator on the intestinal transportation of MDQ-TS by using a single-pass intestinal perfusion (SPIP rat model, and the influence of co-existing components on the intestinal transport of the six saponins was discussed. The results showed that effective apparent permeability (Papp of C1, C2, C3, C4, and DC2 administrated in MDQ-TS form had no segment-dependent changes at low and middle dosage levels. C1, C2, C3, D4, DC1, and DC2 administrated in MDQ-TS form all exhibited excellent transmembrane permeability with Papp > 0.12 × 10−2 cm·min−1. Meanwhile, Papp and effective absorption rate constant (Ka values for the most saponins showed concentration dependence and saturation characteristics. After combining with P-gp inhibitor of verapamil, Papp of C2, C3, and DC1 in MDQ-TS group was significantly increased up to about 2.3-fold, 1.4-fold, and 3.4-fold, respectively in comparison to that of non-verapamil added group. Verapamil was found to improve the absorption of C2, C3, and DC1, indicating the involvement of an active transport mechanism in the absorption process. Compared with the

  17. Resistance calculation of un-fully developed two-phase flow through high differential pressure regulating valves

    International Nuclear Information System (INIS)

    Xu Mingyang; Wang Wenran; Wang Jiaying

    1999-01-01

    To reduce the flow velocity in the high differential pressure regulating valve with labyrinth. A type of complicated valve core structure were designed with tortuous flow path made from reversal double elbows. It is very difficult to calculate the pressure-drop of the un-fully developed two-phase flow under high temperature and pressure which flow through the valve core. A calculation method called 'constant (varing) pressure-drop progressing step by step design method' was developed. The complicated flow path was disintegrated into a series of independent resistance units and with the valve stem end progressing step by step the dimensions of the flow path were designed in accordance with the principle that in every position the total pressure-drop of the valve should amount to that required by the design goal curve. In the course of calculating the total pressure-drop, the valve flow path was also divided into a series of independent resistance units. The experiment results show that design flow characteristics are approximately consistent with the flow characteristics measured in the test

  18. Information Flow Through Stages of Complex Engineering Design Projects: A Dynamic Network Analysis Approach

    DEFF Research Database (Denmark)

    Parraguez, Pedro; Eppinger, Steven D.; Maier, Anja

    2015-01-01

    The pattern of information flow through the network of interdependent design activities is thought to be an important determinant of engineering design process results. A previously unexplored aspect of such patterns relates to the temporal dynamics of information transfer between activities...... information flows between activities in complex engineering design projects; 2) we show how the network of information flows in a large-scale engineering project evolved over time and how network analysis yields several managerial insights; and 3) we provide a useful new representation of the engineering...... as those activities are implemented through the network of people executing the project. To address this gap, we develop a dynamic modeling method that integrates both the network of people and the network of activities in the project. We then employ a large dataset collected from an industrial setting...

  19. Modeling of sand-water slurry flow through horizontal pipe using CFD

    Directory of Open Access Journals (Sweden)

    Kumar Gopaliya Manoj

    2016-09-01

    Full Text Available The paper presents three-dimensional CFD analysis of two-phase (sand-water slurry flows through 263 mm diameter pipe in horizontal orientation for mixture velocity range of 3.5-4.7 m/s and efflux concentration range of 9.95-34% with three particle sizes viz. 0.165 mm, 0.29 mm and 0.55 mm with density 2650 kg/m3. RNG k-ε turbulence closure equations with Eulerian multi-phase model is used to simulate various slurry flows. The simulated values of local solid concentration are compared with the experimental data and are found to be in good agreement for all particle sizes. Effects of particle size on various slurry flow parameters such as pressure drop, solid phase velocity distribution, friction factor, granular pressure, turbulent viscosity, turbulent kinetic energy and its dissipation have been analyzed.

  20. Oxygen Transfer Model for a Flow-Through Hollow-Fiber Membrane Biofilm Reactor

    DEFF Research Database (Denmark)

    Gilmore, K. R.; Little, J. C.; Smets, Barth F.

    2009-01-01

    A mechanistic oxygen transfer model was developed and applied to a flow-through hollow-fiber membrane-aerated biofilm reactor. Model results are compared to conventional clean water test results as well as performance data obtained when an actively nitrifying biofilm was present on the fibers......-liquid interface was the most accurate of the predictive models (overpredicted by a factor of 1.1) while a coefficient determined by measuring bulk liquid dissolved oxygen underpredicted the oxygen transfer by a factor of 3. The mechanistic model was found to be an adequate tool for design because it used....... With the biofilm present, oxygen transfer efficiencies between 30 and 55% were calculated from the measured data including the outlet gas oxygen concentration, ammonia consumption stoichiometry, and oxidized nitrogen production stoichiometry, all of which were in reasonable agreement. The mechanistic model...

  1. Electro-osmotic flow through a thin channel with gradually varying wall potential and hydrodynamic slippage

    International Nuclear Information System (INIS)

    Ng Chiuon; Zhou Qi

    2012-01-01

    The lubrication approximation is applied to electro-osmotic flow through a thin parallel-plate channel under the combined effect of charge and hydrodynamic slippage modulation on the walls. The walls are periodically patterned for the charge and slip distributions, with a wavelength much longer than the channel height. It is shown that the phase of the wall patterns will play a significant role in determining the section-averaged velocity as well as the local convection pattern, both quantitatively and qualitatively. The effect of the phase on the flow will be dramatically different, depending on whether the electric field is applied along or perpendicular to the varying direction of the patterns. The possibility of generating a net flow in a direction perpendicular to the applied field is demonstrated. (paper)

  2. Mathematical Modelling of Blood Flow through a Tapered Overlapping Stenosed Artery with Variable Viscosity

    Directory of Open Access Journals (Sweden)

    G. C. Shit

    2014-01-01

    Full Text Available This paper presents a theoretical study of blood flow through a tapered and overlapping stenosed artery under the action of an externally applied magnetic field. The fluid (blood medium is assumed to be porous in nature. The variable viscosity of blood depending on hematocrit (percentage volume of erythrocytes is taken into account in order to improve resemblance to the real situation. The governing equation for laminar, incompressible and Newtonian fluid subject to the boundary conditions is solved by using a well known Frobenius method. The analytical expressions for velocity component, volumetric flow rate, wall shear stress and pressure gradient are obtained. The numerical values are extracted from these analytical expressions and are presented graphically. It is observed that the influence of hematocrit, magnetic field and the shape of artery have important impact on the velocity profile, pressure gradient and wall shear stress. Moreover, the effect of primary stenosis on the secondary one has been significantly observed.

  3. Use of Continuous Magnetic Extraction for removal of feedstock contaminants in flow-through mode

    DEFF Research Database (Denmark)

    Paulus, Anja; Fischer, Ingo; Hobley, Timothy John

    2014-01-01

    for binding large amounts of product. It can also be especially interesting if obtaining a high product yield is secondary to other considerations. For example if an excess of a low value waste stream is available, it may be acceptable that some target is lost to the adsorbent during contaminant binding......During downstream processing, it may sometimes be more favorable to use adsorbents to bind the contaminants rather than the product. This so-called flow-through mode is especially useful for feed streams where contaminants are in low concentrations, because less adsorbent is required than......-Birk protease inhibitor which has an anti-carcinogenic effect. It was found that using anion exchange magnetic particles as the impurity adsorbing agent, Continuous Magnetic Extraction of contaminants led to a BBI preparation with purity approaching 97% and with yield of 55% in a 15L pilot scale system....

  4. The WUW ML bundle detector A flow through detector for alpha-emitters

    CERN Document Server

    Wenzel, U; Lochny, M

    1999-01-01

    Using conventional laboratory ware, we designed and manufactured a flow through cell for monitoring alpha-bearing solutions. The cell consists of a bundle of thermoplastic, transparent tubes coated with a thin layer of the meltable scintillator MELTILEX sup T sup M at the inner surface. With appropriate energy windows set, the detector can suppress beta-particles to a great extent due to its geometrical dimensions. For pure alpha-solutions, the detection limits are 5 Bq/ml, for composite nuclide mixtures, the detector is capable to monitor the decontamination of medium active waste (<=10 sup 7 Bq/ml) down to 100 Bq alpha/g solution. At a throughput of 1 ml/s, the pressure build-up amounts to approx 2 bar. We have developed a quality control program to ensure the regularity of the individual bundle loops.

  5. Air-water two-phase flow through a pipe junction

    International Nuclear Information System (INIS)

    Suu, Tetsuo

    1991-01-01

    The distribution of the local void fraction across the section of the conduit was studied experimentally in air-water two-phase flow flowing through a pipe junction with the branching angle of 90deg and the area ratio of unity. As in the previous report, the main conduit of the junction was set up vertically and upward air-water bubbly and slug flows were arranged in the main upstream section. If the flow regime, the quality and the ratio of lateral mass flow discharge of water to total mass flow discharge of water are the same, the larger the Reynolds number is, the more violent the variety of the local void fraction distribution adjacent to the branching part in the lateral conduit is. However, the variety in the main downstream section is scarcely influenced by the Reynolds number. (author)

  6. Numerical simulation of 3-D turbulent flow through entire stage in a multistage centrifugal pump

    International Nuclear Information System (INIS)

    Huang, S.; Islam, M.F.; Liu, P.

    2005-01-01

    A three-dimensional turbulent flow through a multistage centrifugal pump is numerically simulated using a commercial CFD software package. The simulation and analysis include flow fields in rotating impeller and stationary diffuser and is completed in a multiple reference frame. The standard k-ε turbulence model is applied. The analysis of the simulation reveals that the reverse flows exist in the zone near the impeller exit and diffuser entrance, resulting in flow field asymmetric and unsteady. There is a considerable interference on velocity field at impeller exit due to the interaction between impeller blades and diffuser vanes. The hydraulic performance is connected and evaluated with the 3-D computational flow field. The current computation is verified by comparing predicted and measured head. (author)

  7. Pulsatile turbulent flow through pipe bends at high Dean and Womersley numbers

    International Nuclear Information System (INIS)

    Kalpakli, Athanasia; Örlü, Ramis; Tillmark, Nils; Alfredsson, P Henrik

    2011-01-01

    Turbulent pulsatile flows through pipe bends are prevalent in internal combustion engine components which consist of bent pipe sections and branching conduits. Nonetheless, most of the studies related to pulsatile flows in pipe bends focus on incompressible, low Womersley and low Dean number flows, primarily because they aim in modeling blood flow, while internal combustion engine related flows have mainly been addressed in terms of integral quantities and consist of single point measurements. The present study aims at bridging the gap between these two fields by means of time-resolved stereoscopic particle image velocimetry measurements in a pipe bend with conditions that are close to those encountered in exhaust manifolds. The time/phase-resolved three-dimensional cross-sectional flow-field 3 pipe diameters downstream the pipe bend is captured and the interplay between different secondary motions throughout a pulse cycle is discussed.

  8. Numerical Simulation of Non-Equilibrium Two-Phase Wet Steam Flow through an Asymmetric Nozzle

    Directory of Open Access Journals (Sweden)

    Miah Md Ashraful Alam

    2017-11-01

    Full Text Available The present study reported of the numerical investigation of a high-speed wet steam flow through an asymmetric nozzle. The spontaneous non-equilibrium homogeneous condensation of wet steam was numerically modeled based on the classical nucleation theory and droplet growth rate equation combined with the field conservations within the computational fluid dynamics (CFD code of ANSYS Fluent 13.0. The equations describing droplet formations and interphase change were solved sequentially after solving the main flow conservation equations. The calculations were carried out assuming the flow two-dimensional, compressible, turbulent, and viscous. The SST k-ω model was used for modeling the turbulence within an unstructured mesh solver. The validation of numerical model was accomplished, and the results showed a good agreement between the numerical simulation and experimental data. The effect of spontaneous non-equilibrium condensation on the jet and shock structures was revealed, and the condensation shown a great influence on the jet structure.

  9. Calculating residual flows through a multiple-inlet system: the conundrum of the tidal period

    Science.gov (United States)

    Duran-Matute, Matias; Gerkema, Theo

    2015-11-01

    The concept of residual, i.e., tidally-averaged, flows through a multiple inlet system is reappraised. The evaluation of the residual through-flow depends on the time interval over which is integrated, in other words, on how one defines the tidal period. It is demonstrated that this definition is ambiguous and that different definitions (based on, e.g., high waters, slack tides, etc.) yield very different results for the residual, also in terms of their long-term statistical properties (median and standard deviation). A basin-wide applicable method of defining the tidal period, in terms of enclosed water volume, is analyzed. We compare the different methods on the basis of high-resolution model results for the Western Dutch Wadden Sea. The multitude of tidal constituents together with wind variability creates broad distributions for the residuals, with standard deviations much larger than the mean or median residual flows.

  10. A mathematical model for metastable condition determination in highly flashing liquid flows through expansion devices

    International Nuclear Information System (INIS)

    Angelo, E.; Angelo, G.; Andrade, D.A.

    2012-01-01

    Highlights: ► A mathematical model to determine the metastable flow degree in expansions. ► This model is based on the evaporation wave theory and a pressure jump discontinuity condition. ► The proposed model is not appropriate in cases where is present a low intensity evaporation wave. - Abstract: The determination of the metastability condition in fluid flows through singularities (expansion devices) when flashing occurs is the key to determine the mass flow rate going through devices when there is a great pressure difference between upstream and downstream. An application of the evaporation waves considered together with a maximizing condition for the pressure jump through the wave to determine the metastable state is presented. The model results are compared to several outflows reported in the literature indicating values within engineering standards for those flows in which fluids are highly superheated (highly expanded flashing liquid jets).

  11. Oil-in-water emulsions flow through constricted micro-capillarities

    Energy Technology Data Exchange (ETDEWEB)

    Castillo, Oswaldo Robles; Carvalho, Marcio da Silveira [Pontificia Universidade Catolica do Rio de Janeiro (PUC-Rio), RJ (Brazil). Dept. of Mechanical Engineering

    2010-07-01

    The effect of the oil concentration and the drop size distribution on the characteristics of the flow of an emulsion through a constricted capillary was experimentally analyzed and quantified by the ratio of the pressure drop of the continuous phase flow to the pressure drop of the emulsion flow, at the same flow rate. The results confirm that the ratio between the capillary constriction diameter and the oil drop size is one of the most important parameters for this flow. For large oil drop size emulsions, the deformation of the drop as it flows through the constriction leads to a high extra pressure drop at low capillary numbers. For small oil drop size emulsions, the extra pressure drop is a function of the viscosity ratio and the disperse phase concentration. (author)

  12. The Dynamic Behavior of Water Flowing Through Packed Bed of Different Particle Shapes and Sizes

    Directory of Open Access Journals (Sweden)

    Haneen Ahmed Jasim

    2017-12-01

    Full Text Available An experimental study was conducted on pressure drop of water flow through vertical cylindrical packed beds in turbulent region and the influence of the operating parameters on its behavior. The bed packing was made of spherical and non-spherical particles (spheres, Rasching rings and intalox saddle with aspect ratio range 3.46 D/dp 8.486 obtaining bed porosities 0.396 0.84 and Reynolds number 1217 21758. The system is consisted of 5 cm inside diameter Perspex column, 50 cm long; distilled water was pumped through the bed with flow rate 875, 1000, 1125, 1250,1375 and 1500 l/h and inlet water temperature 20, 30, 40 and 50 ˚C. The packed bed system was monitored by using LabVIEW program, were the results have been obtained from Data Acquisition Adaptor (DAQ.

  13. Aerodynamics of the Large-Volume, Flow-Through Detector System. Final report

    International Nuclear Information System (INIS)

    Reed, H.; Saric, W.; Laananen, D.; Martinez, C.; Carrillo, R.; Myers, J.; Clevenger, D.

    1996-03-01

    The Large-Volume Flow-Through Detector System (LVFTDS) was designed to monitor alpha radiation from Pu, U, and Am in mixed-waste incinerator offgases; however, it can be adapted to other important monitoring uses that span a number of potential markets, including site remediation, indoor air quality, radon testing, and mine shaft monitoring. Goal of this effort was to provide mechanical design information for installation of LVFTDS in an incinerator, with emphasis on ability to withstand the high temperatures and high flow rates expected. The work was successfully carried out in three stages: calculation of pressure drop through the system, materials testing to determine surrogate materials for wind-tunnel testing, and wind-tunnel testing of an actual configuration

  14. Studies on transport phenomena in polymer solutions and suspensions flowing through tubes of tortuous wall geometry

    Science.gov (United States)

    Narayanan, C. M.

    2014-02-01

    Attempts have been made to analyse the momentum and heat transfer characteristics in tortuous flow of non-Newtonian fluids such as suspensions and polymer solutions through tubes of diverging-converging geometry. The results of the study indicate that the transfer coefficients are significantly higher in such systems as compared to the conventional couette flow (through uniform cylindrical tubes). Moreover, the simultaneous increase in pressure drop due to the tortuous wall geometry has been observed to be relatively insignificant. Fluids with different rheological characteristics such as Bingham plastic fluids, pseudoplastic fluids, Ellis model fluids and fluids obeying Reiner-Philippoff rheology have been studied. The specific advantages of these geometries in providing enhanced performance efficiency have been effectively highlighted.

  15. Heat exchange effectiveness and pressure drop for air flow through perforated plates with and without crosswind

    Science.gov (United States)

    Kutscher, C. F.

    1994-05-01

    Low-porosity perforated plates are being used as absorbers for heating ambient air in a new type of unglazed solar collector. This paper investigates the convective heat transfer effectiveness for low-speed air flow through thin, isothermal perforated plates with and without a crosswind on the upstream face. The objective of this work is to provide information that will allow designers to optimize hole size and spacing. In order to obtain performance data, a wind tunnel and small lamp array were designed and built. Experimental data were taken for a range of plate porosities from 0.1 to 5 percent, hole Reynolds numbers from 100 to 2000, and wind speeds from 0 to 4 m/s. Correlations were developed for heat exchange effectiveness and also for pressure drop. Infrared thermography was used to visualize the heat transfer taking place at the surface.

  16. A study of transcritical carbon dioxide flow through adiabatic capillary tubes

    Energy Technology Data Exchange (ETDEWEB)

    da Silva, Diogo L.; Hermes, Christian J.L.; Melo, Claudio [POLO Research Laboratories for Emerging Technologies in Cooling and Thermophysics, Federal University of Santa Catarina, 88040-970 Florianopolis, SC (Brazil); Goncalves, Joaquim M. [CEFET/SC, Rua Jose Lino Kretzer 608, 88103-310 Sao Jose, SC (Brazil); Weber, Gustavo C. [EMBRACO S.A., Rua Rui Barbosa 1020, 89219-901 Joinville, SC (Brazil)

    2009-08-15

    This paper advances a study of the transcritical expansion of carbon dioxide (R-744, CO{sub 2}) through adiabatic capillary tubes. The influence of both operating conditions (inlet and exit pressures, inlet temperature) and tube geometry (capillary diameter and tube length) on the CO{sub 2} mass flow rate was experimentally evaluated using a purpose-built testing facility with a strict control of the measured variables. A dimensionless correlation to predict the refrigerant mass flow rate as a function of tube geometry and operating conditions was developed. In addition, a theoretical model was put forward based on the mass, energy and momentum conservation principles. The model results were compared with experimental data, when it was found that the model predicts 95% of the measured refrigerant mass flow rate within an error band of {+-}10%. The model was also employed to advance the knowledge about the transcritical carbon dioxide flow through adiabatic capillary tubes. (author)

  17. Unsteady MHD blood flow through porous medium in a parallel plate channel

    Science.gov (United States)

    Latha, R.; Rushi Kumar, B.

    2017-11-01

    In this study, we have analyzed heat and mass transfer effects on unsteady blood flow through parallel plate channel in a saturated porous medium in the presence of a transverse magnetic field with thermal radiation. The governing higher order nonlinear PDE’S are converted to dimensionless equations using dimensionless variables. The dimensionless equations are then solved analytically using boundary conditions by choosing the axial flow transport and the fields of concentration and temperature apart from the normal velocity as a function of y and t. The effects of different pertinent parameters appeared in this model viz thermal radiation, Prandtl number, Heat source parameter, Hartmann number, Permeability parameter, Decay parameter on axial flow transport and the normal velocity are analyzed in detail.

  18. Discussion on Flow-Through Phenomena in the Air Gauge Cascade

    Directory of Open Access Journals (Sweden)

    Jermak Czesław Janusz

    2017-03-01

    Full Text Available In the paper, the flow-through phenomena in the air gauge are under discussion form the thermodynamic and gasodynamic perspective. The main elements of the cascade are considered the inlet nozzle (restriction, measuring chamber and the measuring nozzle with the measuring slot (displacement between the nozzle head and measured surface. The purpose of the analysis was to point out the impact on the metrological characteristics of the air gauge. In particular, attention was paid to the airflow through the measuring slot. Here, the complex phenomena take place, among others the supersonic areas and a “bubble ring,” which cause discontinuity and hysteresis in the static characteristic. On the other hand, the air stream expansion after the restriction (inlet nozzle is observed in the measuring chamber. The point of the above discussion was to work out some recommendation on the nozzles geometry and the localization of the back-pressure measuring point in the chamber.

  19. Flow-through lipid nanotube arrays for structure-function studies of membrane proteins by solid-state NMR spectroscopy.

    Science.gov (United States)

    Chekmenev, Eduard Y; Gor'kov, Peter L; Cross, Timothy A; Alaouie, Ali M; Smirnov, Alex I

    2006-10-15

    A novel method for studying membrane proteins in a native lipid bilayer environment by solid-state NMR spectroscopy is described and tested. Anodic aluminum oxide (AAO) substrates with flow-through 175 nm wide and 60-mum-long nanopores were employed to form macroscopically aligned peptide-containing lipid bilayers that are fluid and highly hydrated. We demonstrate that the surfaces of both leaflets of such bilayers are fully accessible to aqueous solutes. Thus, high hydration levels as well as pH and desirable ion and/or drug concentrations could be easily maintained and modified as desired in a series of experiments with the same sample. The method allows for membrane protein NMR experiments in a broad pH range that could be extended to as low as 1 and as high as 12 units for a period of up to a few hours and temperatures as high as 70 degrees C without losing the lipid alignment or bilayers from the nanopores. We demonstrate the utility of this method by a solid-state 19.6 T (17)O NMR study of reversible binding effects of mono- and divalent ions on the chemical shift properties of the Leu(10) carbonyl oxygen of transmembrane pore-forming peptide gramicidin A (gA). We further compare the (17)O shifts induced by binding metal ions to the binding of protons in the pH range from 1 to 12 and find a significant difference. This unexpected result points to a difference in mechanisms for ion and proton conduction by the gA pore. We believe that a large number of solid-state NMR-based studies, including structure-function, drug screening, proton exchange, pH, and other titration experiments, will benefit significantly from the method described here.

  20. Reduced blood flow through intrapulmonary arteriovenous anastomoses during exercise in lowlanders acclimatizing to high altitude.

    Science.gov (United States)

    Boulet, Lindsey M; Lovering, Andrew T; Tymko, Michael M; Day, Trevor A; Stembridge, Mike; Nguyen, Trang Anh; Ainslie, Philip N; Foster, Glen E

    2017-06-01

    What is the central question of this study? The aim was to determine, using the technique of agitated saline contrast echocardiography, whether exercise after 4-7 days at 5050 m would affect blood flow through intrapulmonary arteriovenous anastomoses (Q̇IPAVA) compared with exercise at sea level. What is the main finding and its importance? Despite a significant increase in both cardiac output and pulmonary pressure during exercise at high altitude, there is very little Q̇IPAVA at rest or during exercise after 4-7 days of acclimatization. Mathematical modelling suggests that bubble instability at high altitude is an unlikely explanation for the reduced Q̇IPAVA. Blood flow through intrapulmonary arteriovenous anastomoses (Q̇IPAVA) is elevated during exercise at sea level (SL) and at rest in acute normobaric hypoxia. After high altitude (HA) acclimatization, resting Q̇IPAVA is similar to that at SL, but it is unknown whether this is true during exercise at HA. We reasoned that exercise at HA (5050 m) would exacerbate Q̇IPAVA as a result of heightened pulmonary arterial pressure. Using a supine cycle ergometer, seven healthy adults free from intracardiac shunts underwent an incremental exercise test at SL [25, 50 and 75% of SL peak oxygen consumption (V̇O2 peak )] and at HA (25 and 50% of SL V̇O2 peak ). Echocardiography was used to determine cardiac output (Q̇) and pulmonary artery systolic pressure (PASP), and agitated saline contrast was used to determine Q̇IPAVA (bubble score; 0-5). The principal findings were as follows: (i) Q̇ was similar at SL rest (3.9 ± 0.47 l min -1 ) compared with HA rest (4.5 ± 0.49 l min -1 ; P = 0.382), but increased from rest during both SL and HA exercise (P exercise (P = 0.003); (iii) Q̇IPAVA was increased from SL rest (0) to HA rest (median = 1; P = 0.04) and increased from resting values during SL exercise (P exercise (P = 0.91), despite significant increases in Q̇ and PASP. Theoretical

  1. Flow-through nanohole array based sensor implemented on analogue smartphone components

    Science.gov (United States)

    Gomez-Cruz, Juan; Nair, Srijit; Ascanio, Gabriel; Escobedo, Carlos

    2017-08-01

    Mobile communications have massively populated the consumer electronics market over the past few years and it is now ubiquitous, providing a timeless opportunity for the development of smartphone-based technologies as point-of-care (POC) diagnosis tools1 . The expectation for a fully integrated smartphone-based sensor that enables applications such as environmental monitoring, explosive detection and biomedical analysis has increased among the scientific community in the past few years2,3. The commercialization forecast for smartphone-based sensing technologies is very promising, but reliable, miniature and cost-effective sensing platforms that can adapt to portable electronics in still under development. In this work, we present an integrated sensing platform based on flow-through metallic nanohole arrays. The nanohole arrays are 260 nm in diameter and 520 nm in pitch, fabricated using Focused Ion Beam (FIB) lithography. A white LED resembling a smartphone flash LED serves as light source to excite surface plasmons and the signal is recorded via a Complementary Metal-Oxide-Semiconductor (CMOS) module. The sensing abilities of the integrated sensing platform is demonstrated for the detection of (i) changes in bulk refractive index (RI), (ii) real-time monitoring of surface modification by receptor-analyte system of streptavidin-biotin.

  2. An investigation of sulfate production in clouds using a flow-through chemical reactor model approach

    Science.gov (United States)

    Hong, M. S.; Carmichael, G. R.

    1983-01-01

    A flow-through chemical reactor model is developed to describe the mass transfer and chemical processes that atmospheric gases undergo in clouds. The model includes the simultaneous absorption of SO2, NH3, O3, NO(x), HNO3, CO2 and H2O2, the accompanying dissociation and oxidation reactions in cloud water, considers electrical neutrality, and includes qualitative parameterization of cloud microphysics. The model is used to assess the importance of the oxidation reactions H2O2-S(IV), O3-S(IV), and S(IV)-Mn(2+) catalysis, and the effects of cloud parameters such as drop size, rain intensity, liquid water content, and updraft velocity. Both precipitating and nonprecipitating clouds are studied. Model results predict sulfate production rates varying from 3 percent/hr to 230 percent/hr. The actual rate is highly dependent on the chemical composition of the uptake air and the physical conditions of the cloud. Model results also show that both the H2O2 and the O3 oxidation reactions can be significant.

  3. Self-sustained oscillations in blood flow through a honeycomb capillary network.

    Science.gov (United States)

    Davis, J M; Pozrikidis, C

    2014-09-01

    Numerical simulations of unsteady blood flow through a honeycomb network originating at multiple inlets and terminating at multiple outlets are presented and discussed under the assumption that blood behaves as a continuum with variable constitution. Unlike a tree network, the honeycomb network exhibits both diverging and converging bifurcations between branching capillary segments. Numerical results based on a finite difference method demonstrate that as in the case of tree networks considered in previous studies, the cell partitioning law at diverging bifurcations is an important parameter in both steady and unsteady flow. Specifically, a steady flow may spontaneously develop self-sustained oscillations at critical conditions by way of a Hopf bifurcation. Contrary to tree-like networks comprised entirely of diverging bifurcations, the critical parameters for instability in honeycomb networks depend weakly on the system size. The blockage of one or more network segments due to the presence of large cells or the occurrence of capillary constriction may cause flow reversal or trigger a transition to unsteady flow.

  4. Numerical simulation of strongly swirling turbulent flows through an abrupt expansion

    International Nuclear Information System (INIS)

    Paik, Joongcheol; Sotiropoulos, Fotis

    2010-01-01

    Turbulent swirling flow through an abrupt axisymmetric expansion is investigated numerically using detached-eddy simulation at Reynolds numbers = 3.0 x 10 4 and 1.0 x 10 5 . The effects of swirl intensity on the coherent dynamics of the flow are systematically studied by carrying out numerical simulations over a range of swirl numbers from 0.17 to 1.23. Comparison of the computed solutions with the experimental measurements of shows that the numerical simulations resolve both the axial and swirl mean velocity and turbulence intensity profiles with very good accuracy. Our simulations show that, along with moderate mesh refinement, critical prerequisite for accurate predictions of the flow downstream of the expansion is the specification of inlet conditions at a plane sufficiently far upstream of the expansion in order to avoid the spurious suppression of the low-frequency, large-scale precessing of the vortex core. Coherent structure visualizations with the q-criterion, friction lines and Lagrangian particle tracking are used to elucidate the rich dynamics of the flow as a function of the swirl number with emphasis on the onset of the spiral vortex breakdown, the onset and extent of the on-axis recirculation region and the large-scale instabilities along the shear layers and the pipe wall.

  5. Effect of deformability on fluid flow through a fractured-porous medium

    International Nuclear Information System (INIS)

    Tsang, C.F.; Noorishad, J.; Witherspoon, P.A.

    1985-01-01

    A permeable geologic medium containing interstitial fluids generally undergoes deformation as the fluid pressure changes. Depending on the nature of the medium, the strain ranges from infinitesimal to finite quantities. This response is the result of a coupled hydraulic-mechanical phenomenon which can basically be formulated in the generalized three-dimensional theory of consolidation. Dealing mainly with media of little deformability, traditional hydrogeology accounts for medium deformability as far as it affects the volume of pore spaces, through the introduction of a coefficient of specific storage in the fluid flow equation. This treatment can be justified on the basis of a one-dimensional effective stress law and the assumption of homogeneity of the total stress field throughout the medium. The present paper uses a numerical model called ROCMAS (Noorishad et al., 1982; Noorishad e al., 1984) which was developed to calculate fluid flow through a deformable fractured-porous medium. The code employs the Finite Element Method based on a variational approach. It has been verified against a number of simple analytic solutions. In this work, the code is used to address the role of medium deformability in continuous and pulse testing techniques. The errors that may result because of application of traditional fluid flow methods are discussed. It is found that low pressure continuous well testing or pulse testing procedures can reduce such errors. 16 references, 9 figures, 1 table

  6. Nonlinear dynamics in flow through unsaturated fractured-porous media: Status and perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Faybishenko, Boris

    2002-11-27

    The need has long been recognized to improve predictions of flow and transport in partially saturated heterogeneous soils and fractured rock of the vadose zone for many practical applications, such as remediation of contaminated sites, nuclear waste disposal in geological formations, and climate predictions. Until recently, flow and transport processes in heterogeneous subsurface media with oscillating irregularities were assumed to be random and were not analyzed using methods of nonlinear dynamics. The goals of this paper are to review the theoretical concepts, present the results, and provide perspectives on investigations of flow and transport in unsaturated heterogeneous soils and fractured rock, using the methods of nonlinear dynamics and deterministic chaos. The results of laboratory and field investigations indicate that the nonlinear dynamics of flow and transport processes in unsaturated soils and fractured rocks arise from the dynamic feedback and competition between various nonlinear physical processes along with complex geometry of flow paths. Although direct measurements of variables characterizing the individual flow processes are not technically feasible, their cumulative effect can be characterized by analyzing time series data using the models and methods of nonlinear dynamics and chaos. Identifying flow through soil or rock as a nonlinear dynamical system is important for developing appropriate short- and long-time predictive models, evaluating prediction uncertainty, assessing the spatial distribution of flow characteristics from time series data, and improving chemical transport simulations. Inferring the nature of flow processes through the methods of nonlinear dynamics could become widely used in different areas of the earth sciences.

  7. A Rapid, Multiplexed, High-Throughput Flow-Through Membrane Immunoassay: A Convenient Alternative to ELISA

    Directory of Open Access Journals (Sweden)

    Gonzalo J. Domingo

    2013-04-01

    Full Text Available This paper describes a rapid, high-throughput flow-through membrane immunoassay (FMIA platform. A nitrocellulose membrane was spotted in an array format with multiple capture and control reagents for each sample detection area, and assay steps were carried out by sequential aspiration of sample and reagents through each detection area using a 96-well vacuum manifold. The FMIA provides an alternate assay format with several advantages over ELISA. The high surface area of the membrane permits high label concentration using gold labels, and the small pores and vacuum control provide rapid diffusion to reduce total assay time to ~30 min. All reagents used in the FMIA are compatible with dry storage without refrigeration. The results appear as colored spots on the membrane that can be quantified using a flatbed scanner. We demonstrate the platform for detection of IgM specific to lipopolysaccharides (LPS derived from Salmonella Typhi. The FMIA format provides analytical results comparable to ELISA in less time, provides integrated assay controls, and allows compensation for specimen-to-specimen variability in background, which is a particular challenge for IgM assays.

  8. Modeling of Two-Phase Flow through a Rotating Tube with Twin Exit Branches

    Directory of Open Access Journals (Sweden)

    Sun-Wen Cheng

    2000-01-01

    Full Text Available A numerical model is proposed to determine the dynamic behavior of single-phase and twophase, two-component flows through a horizontal rotating tube with identical twin exit branches. The working fluid, oil, enters the tube through a radial duct attached at one end and exits into open air through the twin radial branches, one located at midway and the other at the end of the tube. The branch-to-tube diameter ratio, rotational speed, and total oil flow rate are varied. It is experimentally revealed in previous study that the air cavitation occurs at lower speeds, leading to a two-phase flow with the air-oil ratio (void fraction varying with the rotating speed. A unique characteristic in two-phase flow, i.e., hysteresis, is found to exist in both oil flow rates and inlet pressure. In theoretical modeling, the governing flow equations are incorporated by empirical equations for hydraulic head losses. The predicted and measured exit oil flow rates are compared with good agreement in both the single-phase and annular flow regimes. Only qualitative agreement is achieved in the bubbly and bubbly-slug flow regimes. The model can be applied to improve the design and thus enhance the performance of automatic transmission lines, and the cooling efficiency of rotating machines and petroleum drilling process.

  9. Measurement of the combined heat and water-vapour flow through clothing under transient conditions

    Science.gov (United States)

    Farnworth, B.; Nordli, B.

    1982-03-01

    A sweating hot plate for the study of combined heat and water-vapor flow through clothing under Transient conditions is described. The results are in good agreement with the mathematical model reported in a previous paper for several model clothing systems. The heat loss through wool clothing was found to be smaller than that through similar polyester clothing during periods of sweating and larger during subsequent periods of drying, because of the effects of absorption of water vapor by hygroscopic materials. A comparison was made of the heat and vapor transmission of the clothing systems by incorporating a vapor-impermeable fabric or the waterproof but vapor-permeable fabric Gore-TEx. Liquid water was observed to condence on the inner surface of both fabrics during periods of sweating but the Gore-TEx dried within a few minutes of the end of the sweating period. Gore-TEx was found to be vapor permeable even at temperatures below 0 degrees C when frost was forming on its inner surface.

  10. Novel flow-through bioremediation system for removing nitrate from nursery discharge water.

    Science.gov (United States)

    Chris Wilson, P; Albano, Joseph P

    2013-11-30

    Nitrate losses in surface runoff water from nursery production areas can be significant. This study evaluated the potential use of microbial-based (denitrification), flow-through bioreactors for their nitrate-remediation ability. Duplicate bioreactor systems were constructed at a local foliage plant nursery. Each bioreactor system consisted of four 242 L tanks with connections alternating between bottom and top. Each tank was filled with approximately 113 L of Kaldness media to provide surface area for attachment of native microflora. Molasses was supplied as a carbon source for denitrification and water flow rates through the systems ranged from 5 to 18 L min(-1) during tests. Automatic water samplers were used to collect composite samples every 15 min from both the inflow and the exit flow water. Results indicate consistent removal of 80-100% of the nitrate flowing into the systems. Accumulation of ammoniacal and nitrite nitrogen did not occur, indicating that the nitrate-nitrogen was removed from the water, and not simply transformed into another water-soluble species. Occasions where removal rates were less than 80% were usually traced to faulty delivery of the carbon source. Results indicate that modular microbial-based bioremediation systems may be a useful tool for helping water managers meet stringent nitrogen water quality regulations, especially at nurseries with limited space for expansion of water retention facilities. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. On the Hydrodynamic Geometry of Flow-Through versus Restricted Lagoons

    Directory of Open Access Journals (Sweden)

    Nikolaos Th. Fourniotis

    2018-02-01

    Full Text Available The classification of a lagoon as a restricted lagoon is shown to depend not solely on its geometry but also on the tidal hydraulics. By numerically simulating the tidal exchange of two lagoons of similar geometrical dimensions, the Nidova lagoon and the Papas lagoon, in Western Greece, subject to very similar tidal forcing, applied to the two tidal inlets in the first case and three in the second, very different residence times are found, namely 2.5 days for the Nidova and 25–30 days for the Papas lagoon. This large difference is attributed to the fact that whereas the Papas lagoon functions as a typical restricted lagoon, in which the water renewal is achieved by mixing in the lagoon of the tidal prism water exchanged within a tidal cycle, the Nidova lagoon functions as a flow-through system because of the differential arrival of the tide at its two tidal inlets. It is suggested that this way of enhancing the flushing rate of a lagoon be considered, whenever possible, when creating a new tidal inlet to the lagoon.

  12. Study of pressure drop, void fraction and relative permeabilities of two phase flow through porous media

    International Nuclear Information System (INIS)

    Chu, W.; Dhir, V.K.; Marshall, J.

    1983-01-01

    An experimental investigation of two phase flow through porous layers formed of non-heated glass particles (nominal diameter 1 to 6 mm) has been made. Particulate bed depths of 30 cm and 70 cm were used. The effect of particle size, particle size distribution and bed porosity on void fraction and pressure drop through a particulate bed formed in a cylindrical test section has been investigated. The superficial velocity of liquid (water) is varied from 1.83 to 18.3 mm/s while the superficial velocity of gas (air) is varied from 0 to 68.4 mm/s. These superficial velocities were chosen so that pressure drop and void fraction measurement could be made for the porous layer in fixed and fluidized states. A model based on drift flux approach has been developed for the void fraction. Using the two phase friction pressure drop data, the relative permeabilities of the two phases have been concluded with void fraction. The void fraction and two phase friction pressure gradient in beds composed of mixtures of spherical particles as well as sharps of different nominal sizes have also been examined. It is found that the models for single size particles are also applicable to mixtures of particles if a mean particle diameter for the mixture is defined

  13. Experimental study on local resistance of two-phase flow through spacer grid with rod bundle

    International Nuclear Information System (INIS)

    Yan Chaoxing; Yan Changqi; Sun Licheng; Tian Qiwei

    2015-01-01

    The experimental study on local resistance of single-phase and two-phase flows through a spacer grid in a vertical channel with 3 × 3 rod bundle was carried out under the normal temperature and pressure. For the case of single-phase flow, the liquid Reynolds number covered the range of 290-18 007. For the case of two-phase flow, the ranges of gas and liquid superficial velocities were 0.013-3.763 m/s and 0.076-1.792 m/s, respectively. A correlation for predicting local resistance of single-phase flow was given based on experimental results. Eight classical two-phase viscosity formulae for homogeneous model were evaluated against the experimental data of two-phase flow. The results show that Dukler model predicts the experimental data well in the range of Re 1 < 9000 while McAdams correlation is the best one for Re 1 ≥ 9000. For all experimental data, Dukler model provides the best prediction with the mean relative error of 29.03%. A new correlation is fitted for the range of Re 1 < 9000 by considering mass quality, two- phase Reynolds number and liquid and gas densities, resulting in a good agreement with the experimental data. (authors)

  14. Static and Continuous flow-through pulsed light technology for pesticide abatement in water.

    Science.gov (United States)

    Baranda, Ana Beatriz; Lasagabaster, Amaia; de Marañón, Iñigo Martínez

    2017-10-15

    Perspectives concerning pulsed light (PL) technology as a novel water decontamination treatment are overviewed in this work. Degradation of atrazine, malathion, chlorpyriphos-methyl and bromopropylate in aqueous solutions at different concentrations was performed employing static and continuous flow-through PL units. Results for both PL systems were compared in terms of efficacy of pesticides degradation and derived photoproducts formed. The pesticides degradation increased with the applied total fluence for both PL systems. In general, PL induced rapid degradation of all studied compounds although some differences were observed in the rate of degradation among them. The most intense treatment in the static unit (11J/cm 2 ) yielded degradations between 60 and 85% whereas degradations between 74 and 93% were observed after exposure to slightly lower fluences (10J/cm 2 ) in the dynamic unit. For both PL systems bromopropylate was the most affected compound. Photodegradation products arose from chemical reactions involving structural changes like dehalogenation, desulfuration, dealkylaytion and oxidation of the alkyl chains. Although further research is needed before an efficient application in full-scale systems, PL appears as a promising technology in order to reduce the presence of pesticides residues in process or waste waters, allowing thereby recirculation of these waters with the subsequent economic and environmental advantages. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Removal of Contaminants from Waste Streams at Gas Evolving Flow-Through Porous Electrodes

    International Nuclear Information System (INIS)

    Mahmoud Saleh, M.

    1999-01-01

    Electrochemical techniques have been used for the removal of inorganic and organic toxic materials from industrial waste streams. One of the most important branch of these electrochemical techniques is the flow-through porous electrode. Such systems allow for the continuous operation and hence continuous removal of the contaminants from waste streams at high rates and high efficiency. However, when there is an evolution of gas bubbles with the removal process, the treatment process needs a much different treatment of both the design and the mathematical treatment of the such these systems. The evolving gas bubbles within the electrode decrease the pore electrolyte conductivity of the porous electrodes, decrease the efficiency and make the current more non-uniform. This cause the under utilization of the reaction area and finally make the electrode inoperable. In this work the harmful effects of the gas bubbles on the performance of the porous electrode will be modeled. The model accounts for the effects of kinetic, mass transfer and gas bubbles resistance on the overall performance of the electrode. This will help in optimizing the operating conditions and the cell design

  16. Simulating the effect of climate extremes on groundwater flow through a lakebed

    Science.gov (United States)

    Virdi, Makhan L.; Lee, Terrie M.; Swancar, Amy; Niswonger, Richard G.

    2012-01-01

    Groundwater exchanges with lakes resulting from cyclical wet and dry climate extremes maintain lake levels in the environment in ways that are not well understood, in part because they remain difficult to simulate. To better understand the atypical groundwater interactions with lakes caused by climatic extremes, an original conceptual approach is introduced using MODFLOW-2005 and a kinematic-wave approximation to variably saturated flow that allows lake size and position in the basin to change while accurately representing the daily lake volume and three-dimensional variably saturated groundwater flow responses in the basin. Daily groundwater interactions are simulated for a calibrated lake basin in Florida over a decade that included historic wet and dry departures from the average rainfall. The divergent climate extremes subjected nearly 70% of the maximum lakebed area and 75% of the maximum shoreline perimeter to both groundwater inflow and lake leakage. About half of the lakebed area subject to flow reversals also went dry. A flow-through pattern present for 73% of the decade caused net leakage from the lake 80% of the time. Runoff from the saturated lake margin offset the groundwater deficit only about half of that time. A centripetal flow pattern present for 6% of the decade was important for maintaining the lake stage and generated 30% of all net groundwater inflow. Pumping effects superimposed on dry climate extremes induced the least frequent but most cautionary flow pattern with leakage from over 90% of the actual lakebed area.

  17. A flow-through amperometric sensor based on dialysis tubing and free enzyme reactors.

    Science.gov (United States)

    Böhm, S; Pijanowska, D; Olthuis, W; Bergveld, P

    2001-08-01

    A generic flow-through amperometric microenzyme sensor is described, which is based on semi-permeable dialysis tubing carrying the sample to be analyzed. This tubing (300 microm OD) is led through a small cavity, containing the working and reference electrode. By filling this cavity with a few microl of an appropriate enzyme solution, an amperometric enzyme sensor results. As the dialysis tubing is impermeable for large molecular species such as enzymes, this approach does not require any immobilization chemistry, and as a consequence the enzyme is present in its natural free form. Based on this principle, amperometric sensors for lactate, glucose, and glutamate were formed by filling cavities, precision machined in Perspex, with buffered solutions containing respectively, lactate-, glucose-, and glutamate-oxidase. All sensors showed a large linear range (0-35 mM for glucose, 0-3 mM for lactate, and 0-5 mM for glutamate) covering the complete physiological range. The lower detection limit was in the order of 15-50 microM. Applicability in flow injection analysis systems is demonstrated.

  18. Current-phase relation of a Bose-Einstein condensate flowing through a weak link

    International Nuclear Information System (INIS)

    Piazza, F.; Smerzi, A.; Collins, L. A.

    2010-01-01

    We study the current-phase relation of a Bose-Einstein condensate flowing through a repulsive square barrier by solving analytically the one-dimensional Gross-Pitaevskii equation. The barrier height and width fix the current-phase relation j(δφ), which tends to j∼cos(δφ/2) for weak barriers and to the Josephson sinusoidal relation j∼sin(δφ) for strong barriers. Between these two limits, the current-phase relation depends on the barrier width. In particular, for wide-enough barriers, we observe two families of multivalued current-phase relations. Diagrams belonging to the first family, already known in the literature, can have two different positive values of the current at the same phase difference. The second family, new to our knowledge, can instead allow for three different positive currents still corresponding to the same phase difference. Finally, we show that the multivalued behavior arises from the competition between hydrodynamic and nonlinear-dispersive components of the flow, the latter due to the presence of a soliton inside the barrier region.

  19. Laser Doppler anemometry measurements of steady flow through two bi-leaflet prosthetic heart valves

    Directory of Open Access Journals (Sweden)

    Ovandir Bazan

    2013-12-01

    Full Text Available INTRODUCTION: In vitro hydrodynamic characterization of prosthetic heart valves provides important information regarding their operation, especially if performed by noninvasive techniques of anemometry. Once velocity profiles for each valve are provided, it is possible to compare them in terms of hydrodynamic performance. In this first experimental study using laser doppler anemometry with mechanical valves, the simulations were performed at a steady flow workbench. OBJECTIVE: To compare unidimensional velocity profiles at the central plane of two bi-leaflet aortic prosthesis from St. Jude (AGN 21 - 751 and 21 AJ - 501 models exposed to a steady flow regime, on four distinct sections, three downstream and one upstream. METHODS: To provide similar conditions for the flow through each prosthesis by a steady flow workbench (water, flow rate of 17L/min. and, for the same sections and sweeps, to obtain the velocity profiles of each heart valve by unidimensional measurements. RESULTS: It was found that higher velocities correspond to the prosthesis with smaller inner diameter and instabilities of flow are larger as the section of interest is closer to the valve. Regions of recirculation, stagnation of flow, low pressure, and flow peak velocities were also found. CONCLUSIONS: Considering the hydrodynamic aspect and for every section measured, it could be concluded that the prosthesis model AGN 21 - 751 (RegentTM is superior to the 21 AJ - 501 model (Master Series. Based on the results, future studies can choose to focus on specific regions of the these valves.

  20. Simulations of pulsatile suspension flow through bileaflet mechanical heart valves to quantify platelet damage

    Science.gov (United States)

    Yun, Brian; Aidun, Cyrus; Yoganathan, Ajit

    2012-11-01

    Studies have shown that high shear stress and long exposure times on platelets have a strong impact on thromboembolic complications in bileaflet mechanical heart valves (BMHVs). This numerical study quantifies the platelet damage incurred in pulsatile flow through various BMHV designs. The lattice-Boltzmann method with external boundary force (LBM-EBF) was implemented to simulate pulsatile flow and capture the dynamics and surface shear stresses of modeled platelets with realistic geometry. The platelets are released in key regions of interest in the geometry as well as at various times of the cardiac cycle. The platelet damage is quantified using a linear shear stress-exposure time blood damage index (BDI) model. The multiscale computational method used to quantitatively measure the BDI during the pulsatile flow has been validated as being able to accurately capture bulk BMHV fluid flow and for accurately quantifying platelet damage in BMHV flows. These simulations will further knowledge of the geometric features and cardiac cycle times that most affect platelet damage. This study will ultimately lead to optimization of BMHV design in order to minimize thromboembolic complications.

  1. Laser Doppler anemometry measurements of steady flow through two bi-leaflet prosthetic heart valves

    Science.gov (United States)

    Bazan, Ovandir; Ortiz, Jayme Pinto; Vieira Junior, Francisco Ubaldo; Vieira, Reinaldo Wilson; Antunes, Nilson; Tabacow, Fabio Bittencourt Dutra; Costa, Eduardo Tavares; Petrucci Junior, Orlando

    2013-01-01

    Introduction In vitro hydrodynamic characterization of prosthetic heart valves provides important information regarding their operation, especially if performed by noninvasive techniques of anemometry. Once velocity profiles for each valve are provided, it is possible to compare them in terms of hydrodynamic performance. In this first experimental study using laser doppler anemometry with mechanical valves, the simulations were performed at a steady flow workbench. Objective To compare unidimensional velocity profiles at the central plane of two bi-leaflet aortic prosthesis from St. Jude (AGN 21 - 751 and 21 AJ - 501 models) exposed to a steady flow regime, on four distinct sections, three downstream and one upstream. Methods To provide similar conditions for the flow through each prosthesis by a steady flow workbench (water, flow rate of 17L/min. ) and, for the same sections and sweeps, to obtain the velocity profiles of each heart valve by unidimensional measurements. Results It was found that higher velocities correspond to the prosthesis with smaller inner diameter and instabilities of flow are larger as the section of interest is closer to the valve. Regions of recirculation, stagnation of flow, low pressure, and flow peak velocities were also found. Conclusions Considering the hydrodynamic aspect and for every section measured, it could be concluded that the prosthesis model AGN 21 - 751 (RegentTM) is superior to the 21 AJ - 501 model (Master Series). Based on the results, future studies can choose to focus on specific regions of the these valves. PMID:24598950

  2. Sensitive HPV Genotyping Based on the Flow-Through Hybridization and Gene Chip

    Directory of Open Access Journals (Sweden)

    Pingping Tao

    2012-01-01

    Full Text Available Persistent infection of high-risk human papillomavirus (HPV has been recognized as the direct cause of cervical carcinoma. Therefore, detection and genotyping of HPV are important to cervical-cancer screening. In this study, we have evaluated the efficacy of flow-through hybridization and gene chip (HybriMax on HPV genotyping through comparison of the results with Hybrid Capture II (HC-II and in situ hybridization (ISH. 591 women were classified into 6 groups according to their histological diagnoses. The overall accordance rate on 13 types of HPV genotypes between HybriMax and HC-II were 92.5% and 100% in the cancer group. The overall accordance was excellent with the Kappa index (KI of 0.814. The value of KI in each group was 0.750 (normal cytological diagnosis, 0.781 (chronic cervicitis, 0.80 (condyloma acuminatum, 0.755 (cervical intraepithelial neoplasia (CIN I, 0.723 (CIN II, and 0.547 (CIN III (0.75>KI>0.4, good; KI≥0.75, excellent. The 10 most common HPV subtype detected by HybriMax were 16, 52/58, 18, 33, 31, 81, 53, 68, and 66 in patients, and 16, 68, 18, 52, 58, 11, 53, 31/39, and 33 in normal controls. In conclusion, HybriMax is an efficient method for HPV genotyping and more suitable for clinical use.

  3. Comparative study of Newtonian physiological blood flow through normal and stenosed carotid artery

    Science.gov (United States)

    Rahman, Mohammad Matiur; Hossain, Md. Anwar; Mamun, Khairuzzaman; Akhter, Most. Nasrin

    2017-06-01

    A numerical simulation is performed to investigate Newtonian physiological flows behavior on three dimensional idealized carotid artery (CA) and single stenosed (75% by area) carotid artery(SCA). The wall vessel is set as rigid during simulation. Bifurcated blood vessel are simulated by using three-dimensional flow analysis. Physiological and parabolic velocity profiles are set out to fix the conditions of inlet boundaries of artery. In other hand, physiological waveform is an important part of compilation and it is successfully done by utilization of Fourier series having sixteen harmonics. The investigation has a Reynolds number range of 94 to 1120. Low Reynolds number k — ω model has been used as governing equation. The investigation has been carried out to characterize the flow behavior of blood in two geometry, namely, (i) Normal carotid artery (CA) and (ii) Stenosed carotid artery (SCA). The Newtonian model has been used to study the physics of fluid. The findings of the two models are thoroughly compared in order to observe there behavioral sequence of flows. The numerical results were presented in terms of velocity, pressure, wall shear stress distributions and cross sectional velocities as well as the streamlines contour. Stenosis disturbs the normal pattern of blood flow through the artery as reduced area. At stenosis region velocity and peak Reynolds number rapidly increase and Reynolds number reach transitional and turbulent region. These flow fluctuation and turbulence have bad effect to the blood vessel which makes to accelerate the progress of stenosis.

  4. Nonlinear dynamics in flow through unsaturated fractured porous media: Status and perspectives

    International Nuclear Information System (INIS)

    Faybishenko, Boris

    2002-01-01

    The need has long been recognized to improve predictions of flow and transport in partially saturated heterogeneous soils and fractured rock of the vadose zone for many practical applications, such as remediation of contaminated sites, nuclear waste disposal in geological formations, and climate predictions. Until recently, flow and transport processes in heterogeneous subsurface media with oscillating irregularities were assumed to be random and were not analyzed using methods of nonlinear dynamics. The goals of this paper are to review the theoretical concepts, present the results, and provide perspectives on investigations of flow and transport in unsaturated heterogeneous soils and fractured rock, using the methods of nonlinear dynamics and deterministic chaos. The results of laboratory and field investigations indicate that the nonlinear dynamics of flow and transport processes in unsaturated soils and fractured rocks arise from the dynamic feedback and competition between various nonlinear physical processes along with complex geometry of flow paths. Although direct measurements of variables characterizing the individual flow processes are not technically feasible, their cumulative effect can be characterized by analyzing time series data using the models and methods of nonlinear dynamics and chaos. Identifying flow through soil or rock as a nonlinear dynamical system is important for developing appropriate short- and long-time predictive models, evaluating prediction uncertainty, assessing the spatial distribution of flow characteristics from time series data, and improving chemical transport simulations. Inferring the nature of flow processes through the methods of nonlinear dynamics could become widely used in different areas of the earth sciences

  5. Numerical simulation of gas flow through unsaturated fractured rock at Yucca Mountain, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, C.A. [Nevada Univ., Las Vegas, NV (United States). Water Resources Center

    1990-01-01

    Numerical analysis is used to identify the physical phenomena associated with barometrically driven gas (air and water vapor) flow through unsaturated fractured rock at Yucca Mountain, Nevada. Results from simple finite difference simulations indicate that for a fractured rock scenario, the maximum velocity of air out of an uncased 10 cm borehole is 0.002 m s{sub {minus}1}. An equivalent porous medium (EPM) model was incorporated into a multiphase, multicomponent simulator to test more complex conceptual models. Results indicate that for a typical June day, a diurnal pressure wave propagates about 160 m into the surrounding Tiva Canyon hydrogeologic unit. Dry air that enters the formation evaporates water around the borehole which reduces capillary pressure. Multiphase countercurrent flow develops in the vicinity of the hole; the gas phase flows into the formation while the liquid phase flows toward the borehole. The effect occurs within 0.5 m of the borehole. The amount of water vapor leaving the formation during 1 day is 900 cm{sup 3}. This is less than 0.1% of the total recharge into the formation, suggesting that the barometric effect may be insignificant in drying the unsaturated zone. However, gas phase velocities out of the borehole (3 m s{sup {minus}1}), indicating that observed flow rates from wells along the east flank of Yucca Mountain were able to be simulated with a barometric model.

  6. Validation of a flow-through sampler for pesticides and polybrominated diphenyl ethers in air

    Science.gov (United States)

    Xiao, Hang; Hung, Hayley; Lei, Ying Duan; Wania, Frank

    At locations without access to the electrical grid, a flow-through sampler (FTS) collects large volumes of air for the analysis of semi-volatile organic compounds (SVOCs). To test its performance under field conditions, an FTS and a traditional pumped high volume air sampler, both using polyurethane foam (PUF) as sampling medium, were co-deployed at the campus of the University of Toronto Scarborough from August 2006 to June 2007. Polybrominated diphenyl ethers (PBDEs) and various pesticides were quantified in the samples taken by both samplers to test the FTS's applicability to relatively non-volatile and slightly polar SVOCs. Air concentrations in samples taken with the FTS over five 2-week periods compare favourably with the average of the concentrations in several 24-h active high volume samples taken during the same period. In particular, time trends, temperature dependence relationships, and isomer ratios show a reasonable agreement between the two sampling techniques. An empirical linear solvation energy relationship for predicting the apparent theoretical plate number of the PUF assembly used in the FTS illustrates the effect of chemical properties, as well as temperature and wind speed, on sampling efficiency. In the absence of electrical power, the FTS can collect SVOCs from large air volumes as reliably and quantitatively as traditional HiVol samplers, although without separating gas and particle phase.

  7. Investigation and visualization of internal flow through particle aggregates and microbial flocs using particle image velocimetry.

    Science.gov (United States)

    Xiao, Feng; Lam, Kit Ming; Li, Xiao-yan

    2013-05-01

    An advanced particle-tracking and flow-visualization technology, particle image velocimetry (PIV), was utilized to investigate the hydrodynamic properties of large aggregates in water. The laser-based PIV system was used together with a settling column to capture the streamlines around two types of aggregates: latex particle aggregates and activated sludge (AS) flocs. Both types of the aggregates were highly porous and fractal with fractal dimensions of 2.13±0.31 for the latex particle aggregates (1210-2144 μm) and 1.78±0.24 for the AS flocs (1265-3737 μm). The results show that PIV is a powerful flow visualization technique capable of determining flow field details at the micrometer scale around and through settling aggregates and flocs. The PIV streamlines provided direct experimental proof of internal flow through the aggregate interiors. According to the PIV images, fluid collection efficiency ranged from 0.052 to 0.174 for the latex particle aggregates and from 0.008 to 0.126 for AS flocs. AS flocs are apparently less permeable than the particle aggregates, probably due to the extracellular polymeric substances (EPSs) produced by bacteria clogging the pores within the flocs. The internal permeation of fractal aggregates and bio-flocs would enhance flocculation between particles and material transport into the aggregates. Copyright © 2013 Elsevier Inc. All rights reserved.

  8. Numerical simulation of gas flow through unsaturated fractured rock at Yucca Mountain, Nevada

    International Nuclear Information System (INIS)

    Cooper, C.A.

    1990-01-01

    Numerical analysis is used to identify the physical phenomena associated with barometrically driven gas (air and water vapor) flow through unsaturated fractured rock at Yucca Mountain, Nevada. Results from simple finite difference simulations indicate that for a fractured rock scenario, the maximum velocity of air out of an uncased 10 cm borehole is 0.002 m s -1 . An equivalent porous medium (EPM) model was incorporated into a multiphase, multicomponent simulator to test more complex conceptual models. Results indicate that for a typical June day, a diurnal pressure wave propagates about 160 m into the surrounding Tiva Canyon hydrogeologic unit. Dry air that enters the formation evaporates water around the borehole which reduces capillary pressure. Multiphase countercurrent flow develops in the vicinity of the hole; the gas phase flows into the formation while the liquid phase flows toward the borehole. The effect occurs within 0.5 m of the borehole. The amount of water vapor leaving the formation during 1 day is 900 cm 3 . This is less than 0.1% of the total recharge into the formation, suggesting that the barometric effect may be insignificant in drying the unsaturated zone. However, gas phase velocities out of the borehole (3 m s -1 ), indicating that observed flow rates from wells along the east flank of Yucca Mountain were able to be simulated with a barometric model

  9. Validation of the flow-through chamber (FTC and steady-state (SS methods for clearance rate measurements in bivalves

    Directory of Open Access Journals (Sweden)

    Poul S. Larsen

    2011-09-01

    To obtain precise and reliable laboratory clearance rate (filtration rate measurements with the ‘flow-through chamber method’ (FTC the design must ensure that only inflow water reaches the bivalve's inhalant aperture and that exit flow is fully mixed. As earlier recommended these prerequisites can be checked by a plot of clearance rate (CR versus increasing through-flow (Fl to reach a plateau, which is the true CR, but we also recommend to plot percent particles cleared versus reciprocal through-flow where the plateau becomes the straight line CR/Fl, and we emphasize that the percent of particles cleared is in itself neither a criterion for valid CR measurement, nor an indicator of appropriate ‘chamber geometry’ as hitherto adapted in many studies. For the ‘steady-state method’ (SS, the design must ensure that inflow water becomes fully mixed with the bivalve's excurrent flow to establish a uniform chamber concentration prevailing at its incurrent flow and at the chamber outlet. These prerequisites can be checked by a plot of CR versus increasing Fl, which should give the true CR at all through-flows. Theoretically, the experimental uncertainty of CR for a given accuracy of concentration measurements depends on the percent reduction in particle concentration (100×P from inlet to outlet of the ideal ‘chamber geomety’. For FTC, it decreases with increasing values of P while for SS it first decreases but then increases again, suggesting the use of an intermediate value of P. In practice, the optimal value of P may depend on the given ‘chamber geometry’. The fundamental differences between the FTC and the SS methods and practical guidelines for their use are pointed out, and new data on CR for the blue mussel, Mytilus edulis, illustrate a design and use of the SS method which may be employed in e.g. long-term growth experiments at constant algal concentrations.

  10. Assembly and Stacking of Flow-through Enzymatic Bioelectrodes for High Power Glucose Fuel Cells.

    Science.gov (United States)

    Abreu, Caroline; Nedellec, Yannig; Gross, Andrew J; Ondel, Olivier; Buret, Francois; Goff, Alan Le; Holzinger, Michael; Cosnier, Serge

    2017-07-19

    Bioelectrocatalytic carbon nanotube based pellets comprising redox enzymes were directly integrated in a newly conceived flow-through fuel cell. Porous electrodes and a separating cellulose membrane were housed in a glucose/oxygen biofuel cell design with inlets and outlets allowing the flow of electrolyte through the entire fuel cell. Different flow setups were tested and the optimized single cell setup, exploiting only 5 mmol L -1 glucose, showed an open circuit voltage (OCV) of 0.663 V and provided 1.03 ± 0.05 mW at 0.34 V. Furthermore, different charge/discharge cycles at 500 Ω and 3 kΩ were applied to optimize long-term stability leading to 3.6 J (1 mW h) of produced electrical energy after 48 h. Under continuous discharge at 6 kΩ, about 0.7 mW h could be produced after a 24 h period. The biofuel cell design further allows a convenient assembly of several glucose biofuel cells in reduced volumes and their connection in parallel or in series. The configuration of two biofuel cells connected in series showed an OCV of 1.35 V and provided 1.82 ± 0.09 mW at 0.675 V, and when connected in parallel, showed an OCV of 0.669 V and provided 1.75 ± 0.09 mW at 0.381 V. The presented design is conceived to stack an unlimited amount of biofuel cells to reach the necessary voltage and power for portable electronic devices without the need for step-up converters or energy managing systems.

  11. Numerical Study On Local Entropy Generation In Compressible Flow Through A Suddenly Expanding Pipe

    Directory of Open Access Journals (Sweden)

    Gamze Bastürk

    2005-02-01

    Full Text Available Abstract: This study presents the investigation of the local entropy generation in compressible flow through a suddenly expanding pipe. Air is used as fluid. The air enters into the pipe with a turbulent profile using 1/7 th power law. The simulations are extended to include different expansion ratios reduced gradually from 5 to 1. To determine the effects of the mass flux, φ" the ambient heat transfer coefficient, hamb, and the inlet temperature, Tin, on the entropy generation rate, the compressible flow is examined for various cases of these parameters. The flow and temperature fields are computed numerically with the help of the Fluent computational fluid dynamics (CFD code. In addition to this CFD code, a computer program has been developed to calculate numerically the entropy generation and other thermodynamic parameters by using the results of the calculations performed for the flow and temperature fields. The values of thermodynamic parameters in the sudden expansion. (SE case are normalized by dividing by their base quantities obtained from the calculations in the uniform cross-section (UC case. The contraction of the radius of the throat (from 0.05 to 0.01 m increases significantly the maximum value of the volumetric entropy generation rate, (about 60% and raises exponentially 11 times the total entropy generation rate with respect to the its base value. The normalized merit number decreases 73% and 40% with the contraction of the cross-section and with the increase of the ambient heat transfer coefficient (from 20 to 100 W/m2-K, respectively, whereas it rises 226% and 43% with the decrease of the maximum mass flux (from 5 to 1 kg/m2-s and with the increase of the inlet temperature (from 400 to 1000 K, respectively. Consequently, the useful energy transfer rate to irreversibility rate improves as the mass flux decreases and as the inlet temperature increases.

  12. A laboratory study of a flow-through fluorometer for measuring oil-in-water levels

    International Nuclear Information System (INIS)

    Lambert, P.; Fieldhouse, B.; Wang, Z.; Fingas, M.; Pearson, L.; Collazzi, E.

    2001-01-01

    An extensive bench-scale test program was conducted to evaluate the performance of the Turner Instruments flow-through model 10AU and model 10 fluorometers for measuring real-time concentrations of oil in water. The objective of the study was to evaluate the performance of the fluorometer resulting from different weathered states of a particular oil. The study, in turn, lead to a review of the influence of an oil's chemical composition on the instrument and detection technique. The results were compared with alternative total petroleum hydrocarbon (TPH) methods. It was determined that several factors in addition to an oil's chemical composition can effect the response of the fluorometer. The 10AU model was equipped with a long wavelength optical kit, the other with the short wavelength optical kit for diesel fuels and light refined oil products. A total of 8 oils were tested, including Alberta Sweet Mixed Blend crude oil, Prudhoe Bay crude oil, Bunker C fuel oil and diesel fuel. A study of the chemical composition of the selected oils found that the results of the fluorometer could not be directly linked to the concentration of any specific aromatic hydrocarbon such as napthalene or to the sum of the polyaromatic hydrocarbons (PAH) compounds. The results showed that the fluorescence signal is generated by a combination of PAH compounds and that the relative contribution of each PAH compound is not equal. It was also determined that the response of the fluorometers may be influenced by the presence of volatile organic compounds such as BTEX and C3-benzenes in combination with PAH compounds. 14 refs., 7 tabs., 4 figs

  13. Numerical analysis of liquid metal MHD flows through circular pipes based on a fully developed modeling

    International Nuclear Information System (INIS)

    Zhang, Xiujie; Pan, Chuanjie; Xu, Zengyu

    2013-01-01

    Highlights: ► 2D MHD code based on a fully developed modeling is developed and validated by Samad analytical results. ► The results of MHD effect of liquid metal through circular pipes at high Hartmann numbers are given. ► M type velocity profile is observed for MHD circular pipe flow at high wall conductance ratio condition. ► Non-uniform wall electrical conductivity leads to high jet velocity in Robert layers. -- Abstract: Magnetohydrodynamics (MHD) laminar flows through circular pipes are studied in this paper by numerical simulation under the conditions of Hartmann numbers from 18 to 10000. The code is developed based on a fully developed modeling and validated by Samad's analytical solution and Chang's asymptotic results. After the code validation, numerical simulation is extended to high Hartmann number for MHD circular pipe flows with conducting walls, and numerical results such as velocity distribution and MHD pressure gradient are obtained. Typical M-type velocity is observed but there is not such a big velocity jet as that of MHD rectangular duct flows even under the conditions of high Hartmann numbers and big wall conductance ratio. The over speed region in Robert layers becomes smaller when Hartmann numbers increase. When Hartmann number is fixed and wall conductance ratios change, the dimensionless velocity is through one point which is in agreement with Samad's results, the locus of maximum value of velocity jet is same and effects of wall conductance ratio only on the maximum value of velocity jet. In case of Robert walls are treated as insulating and Hartmann walls as conducting for circular pipe MHD flows, there is big velocity jet like as MHD rectangular duct flows of Hunt's case 2

  14. Leaf litter processing and energy flow through macroinvertebrates in a woodland pond (Switzerland).

    Science.gov (United States)

    Oertli, B

    1993-12-01

    Energy generated by leaf litter processing and its flow through the associated macroinvertebrate community was quantified in a pond near Geneva (Switzerland). Annual density, biomass, and production on oak (Quercus robur) leaf litter were assessed for all macroinvertebrate taxa with emphasis on predators. Empirical energetic relations provided an energy budget for the macroinvertebrate community. On 1 m 2 of pond bottom, the processing of 5641 kJ of oak leaf litter resulted in 8.5% of leachate (6 days), and after 1 year 32% of material remained; the other 59.5% was biologically (animal or microbial) converted, including 11.2% processed by shredders. The mean annual density of associated macroinvertebrates was 51374 individuals, mean biomass was 3.53 g (dry mass) and production was about 1451 kJ (or 65 g). Predator production was 170 kJ/m 2 , non-chironomid primary consumer production was 101 kJ/m 2 (including 57 kJ from shredders) and chironomid primary consumer production was estimated at 1180 kJ/m 2 . Predators contributed to a high proportion of total biomass (39%) but to a smaller amount of production (12%) or density (6%). In this two-stepped food-chain mainly based on detritus, the transfer coefficient between first level (detritus + primary producers) and third level (secondary consumers) was high (2-2.5%) and indicated efficient conversion of energy. This high efficiency was partly related to the reutilization of fine particulate organic matter by the collectors. The production estimate measured on leaf litter was compared with two other predominant substrates (Typha latifolia stems and Chara sp.), and exhibited the highest value. This study shows how leaf litter can constitute a direct source for high secondary production and be an efficient energy source in freshwater ecosystems. It is also demonstrated that a woodland pond can support a high macroinvertebrate production as compared with other freshwater ecosystems.

  15. Modelling capillary hysteresis effects on preferential flow through melting and cold layered snowpacks

    Science.gov (United States)

    Leroux, Nicolas R.; Pomeroy, John W.

    2017-09-01

    Accurate estimation of the amount and timing of water flux through melting snowpacks is important for runoff prediction in cold regions. Most existing snowmelt models only account for one-dimensional matrix flow and neglect to simulate the formation of preferential flow paths. Consideration of lateral and preferential flows has proven critical to improve the performance of soil and groundwater porous media flow models. A two-dimensional physically-based snowpack model that simulates snowmelt, refreezing of meltwater, heat and water flows, and preferential flow paths is presented. The model assumes thermal equilibrium between solid and liquid phases and uses recent snow physics advances to estimate snowpack hydraulic and thermal properties. For the first time, capillary hysteresis is accounted in a snowmelt model. A finite volume method is applied to solve for the 2D coupled heat and mass transfer equations. The model with capillary hysteresis provided better simulations of water suction at the wet to dry snow interface in a wetting snow sample than did a model that only accounted for the boundary drying curve. Capillary hysteresis also improved simulations of preferential flow path dynamics and the snowpack discharge hydrograph. Simulating preferential flow in a subfreezing snowpack allowed the model to generate ice layers, and increased the vertical exchange of energy, thus modelling a faster warming of the snowpack than would be possible without preferential flow. The model is thus capable of simulating many attributes of heterogeneous natural melting snowpacks. These features not only qualitatively improve water flow simulations, but improve the understanding of snowmelt flow processes for both level and sloping terrain, and illuminate how uncertainty in snowmelt-derived runoff calculations might be reduced through the inclusion of more realistic preferential flow through snowpacks.

  16. Development of a numerical model for fluid-structure interaction analysis of flow through and around an aquaculture net cage

    DEFF Research Database (Denmark)

    Chen, Hao; Christensen, Erik Damgaard

    2017-01-01

    In the present work, we developed a numerical model for fluid-structure interaction analysis of flow through and around an aquaculture net cage. The numerical model is based on the coupling between the porous media model and the lumped mass structural model. A novel interface was implemented...

  17. Evaluation of vertical and lateral flow through agricultural loessial hillslopes using a two-dimensional computer simulation model

    NARCIS (Netherlands)

    Ritsema, C.J.; Oostindie, K.; Stolte, J.

    1996-01-01

    On four hill-slopes in the loess region of the Netherlands pressure heads were monitored during rain events with time intervals of five minutes. Water flow through these hill-slopes during erosive rain events in summer and winter was simulated two-dimensionally. These simulations showed that

  18. Imposed Work of Breathing for Flow Meters with In-Line versus Flow-Through Technique during Simulated Neonatal Breathing.

    Directory of Open Access Journals (Sweden)

    Snorri Donaldsson

    Full Text Available The ability to determine airflow during nasal CPAP (NCPAP treatment without adding dead space or resistance would be useful when investigating the physiologic effects of different NCPAP systems on breathing. The aim of this study was to investigate the effect on pressure stability of different flow measuring devices at the in-line and flow-through position, using simulated neonatal breathing.Six different flow measure devices were evaluated by recording pressure changes and imposed work of breathing for breaths with 16 and 32 ml tidal volumes. The tests were performed initially with the devices in an in line position and with 5 and 10 L/min using flow through technique, without CPAP. The flow meters were then subsequently tested with an Infant Flow CPAP system at 3, 5 and 8 cm H2O pressure using flow through technique. The quality of the recorded signals was compared graphically.The resistance of the measuring devices generated pressure swings and imposed work of breathing. With bias flow, the resistance also generated CPAP pressure. Three of the devices had low resistance and generated no changes in pressure stability or CPAP pressure. The two devices intended for neonatal use had the highest measured resistance.The importance of pressure stability and increased work of breathing during non-invasive respiratory support are insufficiently studied. Clinical trials using flow-through technique have not focused on pressure stability. Our results indicate that a flow-through technique might be a way forward in obtaining a sufficiently high signal quality without the added effects of rebreathing and increased work of breathing. The results should stimulate further research and the development of equipment for dynamic flow measurements in neonates.

  19. Florfenicol residues in rainbow trout after oral dosing in recirculating and flow-through culture systems.

    Science.gov (United States)

    Meinertz, J R; Hess, K R; Bernardy, J A; Gaikowski, M P; Whitsel, M; Endris, R G

    2014-12-01

    Aquaflor is a feed premix for fish containing the broad spectrum antibacterial agent florfenicol (FFC) incorporated at a ratio of 50% (w/w). To enhance the effectiveness of FFC for salmonids infected with certain isolates of Flavobacterium psychrophilum causing cold water disease, the FFC dose must be increased from the standard 10 mg·kg⁻¹ body weight (BW)·d⁻¹ for 10 consecutive days. A residue depletion study was conducted to determine whether FFC residues remaining in the fillet tissue after treating fish at an increased dose would be safe for human consumption. Groups of Rainbow Trout Oncorhynchus mykiss (total n = 144; weight range, 126-617 g) were treated with FFC at 20 mg·kg⁻¹ BW·d⁻¹ for 10 d in a flow-through system (FTS) and a recirculating aquaculture system (RAS) each with a water temperature of ∼13°C. The two-tank RAS included a nontreated tank containing 77 fish. Fish were taken from each tank (treated tank, n = 16; nontreated tank, n = 8) at 6, 12, 24, 48, 72, 120, 240, 360, and 480 h posttreatment. Florfenicol amine (FFA) concentrations (the FFC marker residue) in skin-on fillets from treated fish were greatest at 12 h posttreatment (11.58 μg/g) in the RAS and were greatest at 6 h posttreatment (11.09 μg/g) in the FTS. The half-lives for FFA in skin-on fillets from the RAS and FTS were 20.3 and 19.7 h, respectively. Assimilation of FFC residues in the fillets of nontreated fish sharing the RAS with FFC-treated fish was minimal. Florfenicol water concentrations peaked in the RAS-treated tank and nontreated tanks at 10 h (453 μg/L) and 11 h (442 μg/L) posttreatment, respectively. Monitoring of nitrite concentrations throughout the study indicated the nitrogen oxidation efficiency of the RAS biofilter was minimally impacted by the FFC treatment.

  20. The control of blood flow through human forearm muscles following brief isometric contractions.

    Science.gov (United States)

    Lind, A R; Williams, C A

    1979-03-01

    1. The blood flow through the forearm was measured 2 sec after single, brief isometric hand-grip contractions. The tension and duration of those contractions varied from 10 to 100% of the maximal voluntary contraction (m.v.c.) and from 2 to 12 sec, respectively. 2. The blood flow increased linearly with tension up to about 60% m.v.c. but further increases in tension, up to 100% m.v.c., did not elicit higher blood flows than were found at 60% m.v.c. The same relationship between tension and the resultant blood flow held for all durations of contractions, from 2 to 12 sec. The blood flow immediately after (2 sec) contractions at a given tension increased linearly with the duration of the contraction, from 2 to 12 sec. Maximal exercise blood flow was approached only in response to the longest contractions (12 sec) at tensions of 60% m.v.c. or higher. 3. Brief alterations (2--5 sec) of transmural pressure across blood vessels did not result in a significant change of blood flow, either in the resting forearm or when the vessels were dilated by brief, isometric contractions. When the tension was applied or released either rapidly or gradually ('ramp' contractions) there was no correlation between the rate of change of stretch on arterial vessels and the resultant blood flow. However, there was a direct relationship between a force--time integral (duration of contraction x peak tension) and blood flow. All these results make it clear that changes in blood flow in the forearm elicited by brief isometric contractions are not the result of a myogenic reflex but are metabolically induced. 4. Successive contractions exerted at 60% m.v.c. for 4 sec induced a blood flow of 21.2 +/- 1.6 ml.min-1.100 ml.-1 when a rest interval of 8 sec was allowed between the contractions. Blood flows remained constant at this submaximal level, even when muscular fatigue was induced, and when there was an accompanying large increase in blood pressure. 5. Isometric muscular activity by the

  1. Florfenicol residues in Rainbow Trout after oral dosing in recirculating and flow-through culture systems

    Science.gov (United States)

    Meinertz, Jeffery R.; Hess, Karina R.; Bernady, Jeffry A.; Gaikowski, M. P.; Whitsel, Melissa; Endris, R. G.

    2014-01-01

    Aquaflor is a feed premix for fish containing the broad spectrum antibacterial agent florfenicol (FFC) incorporated at a ratio of 50% (w/w). To enhance the effectiveness of FFC for salmonids infected with certain isolates of Flavobacterium psychrophilum causing coldwater disease, the FFC dose must be increased from the standard 10 mg·kg−1 body weight (BW)·d−1 for 10 consecutive days. A residue depletion study was conducted to determine whether FFC residues remaining in the fillet tissue after treating fish at an increased dose would be safe for human consumption. Groups of Rainbow Trout Oncorhynchus mykiss (total n = 144; weight range, 126–617 g) were treated with FFC at 20 mg·kg−1 BW·d−1 for 10 d in a flow-through system (FTS) and a recirculating aquaculture system (RAS) each with a water temperature of ∼13°C. The two-tank RAS included a nontreated tank containing 77 fish. Fish were taken from each tank (treated tank, n = 16; nontreated tank, n = 8) at 6, 12, 24, 48, 72, 120, 240, 360, and 480 h posttreatment. Florfenicol amine (FFA) concentrations (the FFC marker residue) in skin-on fillets from treated fish were greatest at 12 h posttreatment (11.58 μg/g) in the RAS and were greatest at 6 h posttreatment (11.09 μg/g) in the FTS. The half-lives for FFA in skin-on fillets from the RAS and FTS were 20.3 and 19.7 h, respectively. Assimilation of FFC residues in the fillets of nontreated fish sharing the RAS with FFC-treated fish was minimal. Florfenicol water concentrations peaked in the RAS-treated tank and nontreated tanks at 10 h (453 μg/L) and 11 h (442 μg/L) posttreatment, respectively. Monitoring of nitrite concentrations throughout the study indicated the nitrogen oxidation efficiency of the RAS biofilter was minimally impacted by the FFC treatment.

  2. Competitive adsorption and desorption of strontium and cobalt on acid soils measured in batch and in stirred flow-through reactor

    Energy Technology Data Exchange (ETDEWEB)

    Limousin, G. [CEA - Section d' Application des Traceurs, 38 054 Grenoble Cedex (France)]|[Laboratoire des Transferts en Hydrologie et Environnement, BP 53, 38 041 Grenoble Cedex, (France); Szenknect, S.; Barthes, V. [CEA - Section d' Application des Traceurs, 38 054 Grenoble Cedex (France); Gaudet, J.P. [Laboratoire des Transferts en Hydrologie et Environnement, BP 53, 38 041 Grenoble Cedex (France)

    2005-07-01

    concentration as well. Desorption kinetics were measured with the stirred flow-through reactor. The experiments are currently in progress. The first results are consistent with batch experiments. Besides, it appears that closing the circuit during 10 h before desorption reduces the mass recovery, showing an 'aging effect'. References Szenknect, S., Ardois, C., Gaudet, J.-P., Barthes, V. 2005. Reactive transport of {sup 85}Sr in a Chernobyl sand column: static and dynamic experiment and modeling. Journal of Contaminant Hydrology, 76, 139-165. Martin-Garin, A., Van Cappellen, P., Charlet, C. 2003. Aqueous cadmium uptake by calcite: a stirred flow-through reactor study. Geochimica et Cosmochimica Acta, 67, 2763-2774. (authors)

  3. History independence of steady state in simultaneous two-phase flow through two-dimensional porous media.

    Science.gov (United States)

    Erpelding, Marion; Sinha, Santanu; Tallakstad, Ken Tore; Hansen, Alex; Flekkøy, Eirik Grude; Måløy, Knut Jørgen

    2013-11-01

    It is well known that the transient behavior during drainage or imbibition in multiphase flow in porous media strongly depends on the history and initial condition of the system. However, when the steady-state regime is reached and both drainage and imbibition take place at the pore level, the influence of the evolution history and initial preparation is an open question. Here, we present an extensive experimental and numerical work investigating the history dependence of simultaneous steady-state two-phase flow through porous media. Our experimental system consists of a Hele-Shaw cell filled with glass beads which we model numerically by a network of disordered pores transporting two immiscible fluids. From measurements of global pressure evolution, histograms of saturation, and cluster-size distributions, we find that when both phases are flowing through the porous medium, the steady state does not depend on the initial preparation of the system or on the way it has been reached.

  4. Parallel array of nanochannels grafted with polymer-brushes-stabilized Au nanoparticles for flow-through catalysis.

    Science.gov (United States)

    Liu, Jianxi; Ma, Shuanhong; Wei, Qiangbing; Jia, Lei; Yu, Bo; Wang, Daoai; Zhou, Feng

    2013-12-07

    Smart systems on the nanometer scale for continuous flow-through reaction present fascinating advantages in heterogeneous catalysis, in which a parallel array of straight nanochannels offers a platform with high surface area for assembling and stabilizing metallic nanoparticles working as catalysts. Herein we demonstrate a method for finely modifying the nanoporous anodic aluminum oxide (AAO), and further integration of nanoreactors. By using atomic transfer radical polymerization (ATRP), polymer brushes were successfully grafted on the inner wall of the nanochannels of the AAO membrane, followed by exchanging counter ions with a precursor for nanoparticles (NPs), and used as the template for deposition of well-defined Au NPs. The membrane was used as a functional nanochannel for novel flow-through catalysis. High catalytic performance and instantaneous separation of products from the reaction system was achieved in reduction of 4-nitrophenol.

  5. A numerical model for self-compacting concrete flow through reinforced sections. A porous medium analogy

    Energy Technology Data Exchange (ETDEWEB)

    Vasilic, Ksenija

    2016-05-01

    This thesis addresses numerical simulations of self-compacting concrete (SCC) castings and suggests a novel modelling approach that treats reinforcement zones in a formwork as porous media. As a relatively new field in concrete technology, numerical simulations of fresh concrete flow can be a promising aid to optimise casting processes and to avoid on-site casting incidents by predicting the flow behaviour of concrete during the casting process. The simulations of fresh concrete flow generally involve complex mathematical modelling and time-consuming computations. In case of a casting prediction, the simulation time is additionally significantly increased because each reinforcement bar occurring in succession has to be considered one by one. This is particularly problematic when simulating SCC casting, since this type of concrete is typically used for heavily reinforced structural members. However, the wide use of numerical tools for casting prediction in practice is possible only if the tools are user-friendly and simulations are time-saving. In order to shorten simulation time and to come closer to a practical tool for casting prediction, instead to model steel bars one by one, this thesis suggests to model zones with arrays of steel bars as porous media. Consequently, one models the flow of SCC through a reinforcement zone as a free-surface flow of a non-Newtonian fluid, propagating through the medium. By defining characteristic parameters of the porous medium, the influence on the flow and the changed (apparent) behaviour of concrete in the porous matrix can be predicted. This enables modelling of any reinforcement network as a porous zone and thus significantly simplifies and fastens simulations of reinforced components' castings. Within the thesis, a computational model for SCC flow through reinforced sections was developed. This model couples a fluid dynamics model for fresh concrete and the macroscopic approach for the influence of the porous medium

  6. A numerical model for self-compacting concrete flow through reinforced sections. A porous medium analogy

    International Nuclear Information System (INIS)

    Vasilic, Ksenija

    2016-01-01

    This thesis addresses numerical simulations of self-compacting concrete (SCC) castings and suggests a novel modelling approach that treats reinforcement zones in a formwork as porous media. As a relatively new field in concrete technology, numerical simulations of fresh concrete flow can be a promising aid to optimise casting processes and to avoid on-site casting incidents by predicting the flow behaviour of concrete during the casting process. The simulations of fresh concrete flow generally involve complex mathematical modelling and time-consuming computations. In case of a casting prediction, the simulation time is additionally significantly increased because each reinforcement bar occurring in succession has to be considered one by one. This is particularly problematic when simulating SCC casting, since this type of concrete is typically used for heavily reinforced structural members. However, the wide use of numerical tools for casting prediction in practice is possible only if the tools are user-friendly and simulations are time-saving. In order to shorten simulation time and to come closer to a practical tool for casting prediction, instead to model steel bars one by one, this thesis suggests to model zones with arrays of steel bars as porous media. Consequently, one models the flow of SCC through a reinforcement zone as a free-surface flow of a non-Newtonian fluid, propagating through the medium. By defining characteristic parameters of the porous medium, the influence on the flow and the changed (apparent) behaviour of concrete in the porous matrix can be predicted. This enables modelling of any reinforcement network as a porous zone and thus significantly simplifies and fastens simulations of reinforced components' castings. Within the thesis, a computational model for SCC flow through reinforced sections was developed. This model couples a fluid dynamics model for fresh concrete and the macroscopic approach for the influence of the porous medium

  7. Transesterification by lipase entrapped in electrospun poly(vinyl alcohol) fibers and its application to a flow-through reactor.

    Science.gov (United States)

    Sakai, Shinji; Antoku, Koichi; Yamaguchi, Tetsu; Kawakami, Koei

    2008-06-01

    We entrapped lipase in electrospun poly(vinyl alcohol) fibers of approximately 1 mum in diameter and evaluated the transesterification activity by converting (s)-glycidol to glycidyl n-butyrate with vinyl n-butyrate. The initial transesterification rate of the entrapped lipase was 5.2-fold faster than that of non-treated lipase. The fibrous membrane could be used as a component of a flow-through reactor for continuous transesterification.

  8. Entropy analysis on MHD pseudo-plastic nanofluid flow through a vertical porous channel with convective heating

    OpenAIRE

    Das, S.; Banu, A.S.; Jana, R.N.; Makinde, O.D.

    2015-01-01

    This paper is concerned with the entropy generation in a magnetohydrodynamic (MHD) pseudo-plastic nanofluid flow through a porous channel with convective heating. Three different types of nanoparticles, namely copper, aluminum oxide and titanium dioxide are considered with pseudo-plastic carboxymethyl cellulose (CMC)–water used as base fluids. The governing equations are solved numerically by shooting technique coupled with Runge–Kutta scheme. The effects of the pertinent parameters on the fl...

  9. Disposable lateral flow-through strip for smartphone-camera to quantitatively detect alkaline phosphatase activity in milk.

    Science.gov (United States)

    Yu, Ling; Shi, ZhuanZhuan; Fang, Can; Zhang, YuanYuan; Liu, YingShuai; Li, ChangMing

    2015-07-15

    A disposable lateral flow-through strip was developed for smartphone to fast one-step quantitatively detect alkaline phosphatase (ALP) activity in raw milk. The strip comprises two functional components, a conjugation pad loaded with phosphotyrosine-coated gold nanoparticles (AuNPs@Cys-Try-p) and a testing line coated with anti-phosphotryosine antibody (anti-Tyr-p mAb). The dephosphorylation activity of ALP at the testing zone can be quantitatively assayed by monitoring the accumulated AuNPs-induced color changes by smartphone camera, thus providing a highly convenient portable detection method. A trace amount of ALP as low as 0.1UL(-1) with a linear dynamic range of 0.1-150UL(-1) (R(2)=0.999) in pasteurized milk and raw milk can be one-step detected by the developed flow-through strip within 10min, demonstrating the potential of smartphone-based portable sensing device for pathogen detection. This bio-hazards free lateral flow-through testing strip can be also used to fabricate rapid, sensitive and inexpensive enzyme or immunosensors for broad portable clinic diagnosis and food contamination analysis, particularly in point-of-care and daily food quality inspection. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Study of Co-Current and Counter-Current Gas-Liquid Two-Phase Flow Through Packed Bed in Microgravity

    Science.gov (United States)

    Revankar, Shripad T.

    2002-11-01

    The main goal of the project is to obtain new experimental data and development of models on the co-current and counter-current gas-liquid two-phase flow through a packed bed in microgravity and characterize the flow regime transition, pressure drop, void and interfacial area distribution, and liquid hold up. Experimental data will be obtained for earth gravity and microgravity conditions. Models will be developed for the prediction of flow regime transition, void fraction distribution and interfacial area concentration, which are key parameters to characterize the packed bed performance. Thus the specific objectives of the proposed research are to: (1) Develop experiments for the study of the gas liquid two-phase flow through the packed bed with three different flow combinations: co-current down flow, co-current upflow and counter current flow. (2) Develop pore scale and bed scale two-phase instrumentation for measurement of flow regime transition, void distribution and gas-liquid interfacial area concentration in the packed bed. (3) Obtain database on flow regime transition, pressure drop, void distribution, interfacial area concentration and liquid hold up as a function of bed characteristics such as bed particle size, porosity, and liquid properties such as viscosity and surface tension. (4) Develop mathematical model for flow regime transition, void fraction distribution and interfacial area concentration for co-current gas-liquid flow through the porous bed in gravity and micro gravity conditions.(4) Develop mathematical model for the flooding phenomena in counter-current gas-liquid flow through the porous bed in gravity and micro gravity conditions. The present proposal addresses the most important topic of HEDS-specific microgravity fluid physics research identified by NASA 's one of the strategic enterprises, OBPR Enterprise. The proposed project is well defined and makes efficient use of the ground-based parabolic flight research aircraft facility. The

  11. Influence of the composition and microstructure on the mechanical properties of single pass weld metal obtained with two-run multipower submerged arc welding of 35 MM Fe 510 quality steels

    International Nuclear Information System (INIS)

    Berkhout, C.F.; Sipkes, M.P.

    1977-01-01

    For three 35 mm Fe 510 quality steels (with and without niobium) experiments have been carried out to establish a relationship between composition, microstructure and mechanical properties of weldmetal obtained with two-run multipower submerged arc welding. The most striking aspects are summarized in the following. The weldmental composition can influence the toughness both, directly by matrix alloying or indirectly through the grainsize and constituents of the microstructure such as the perlite-cementite and martensite fraction. In the range of compositions investigated Mn for instance has a beneficial, while Nb and N have a detrimental effect on notch toughness. For nitrogen the concentration in the weldmetal is determined by the type of weldingflux used. The unfavourable effect of Nb in the weldmetal depends mainly on the Nb content of the plate material (dilution effect). Niobium introduced by the flux is not active and in all probability only present as non metallic inclusions. Remarkable is the strong interaction found between Nb and N. The influence of Nb decreases when the N content of the weldmetal increases. This effect may probably also be an explanation for the great differences in the interpretation of the influence of Nb on weldmetal ductility as mentioned in the literature. A change in the concentration of these elements does not have any influence on the grainsize of the weldmetal. The influence of Mo is quite remarkable. In the first place it has a grain-refining effect, which strongly predominates its detrimental effect in promoting the martensite formation. From quantitative measurements it also appears that Mo reduces the amount of perlite in the weldmetal and suppresses entirely the influence of Mn on the Charpy-V transition temperature and the uppershelf-energy level

  12. An experimental and analytical study of flow through a supersonic open channel with contoured floor

    Science.gov (United States)

    Saheli, F. P.; Dunn, B.; Marrs, K.; Kumar, A.; Peery, K. M.

    1984-01-01

    A wind tunnel experiment was performed to study the characteristics of supersonic airflow (M(infinity) = 2.5-3.86) through an open channel with a contoured floor. The measured static pressures along the centerline of the channel floor exhibited an unexpected rise at the end of the channel. Complex three-dimensional interactions of compression and expansion waves within the channel coupled with external flow perturbations caused by model/tunnel wall interference were the suspected sources of this flow behavior. Three-dimensional inviscid flow analysis procedures were used to investigate and explain this phenomenon. The results of the computations and the experiment are presented and discussed.

  13. On the Coupling of Incompressible Stokes or Navier–Stokes and Darcy Flows Through Porous Media

    KAUST Repository

    Girault, V.

    2012-11-03

    In this chapter, we present the theoretical analysis of coupled incompressible Navier-Stokes (or Stokes) flows and Darcy flows with the Beavers-Joseph-Saffman interface condition. We discuss alternative interface and porous media models. We review some finite element methods used by several authors in this coupling and present numerical experiments.

  14. Understanding the Impact of Arterial Stenosis on Blood Flow through a Tissue

    Science.gov (United States)

    Prakash, Elapulli Sankaranarayanan

    2015-01-01

    This article arises from the author's experience helping medical students apply core biophysical principles toward understanding cardiovascular physiology. The purpose of the article is illustrate how the effect of an arterial stenosis on blood flow to tissue supplied exclusively by the stenosed artery should be assessed. This discussion was…

  15. Influence of Reynolds number on coalescence of droplets with particle in flow through a tube at low Reynolds number

    Science.gov (United States)

    Muraoka, Masahiro; Yatagawa, Yuta; Kumagai, Yuki

    2016-07-01

    The coalescence of droplets in flow through a tube at low Reynolds number is potentially useful for different purposes including the handling of fluids, control of chemical reaction, and in drug delivery systems. The phenomenon is also the basis for analyzing the flow of multiphase fluids through porous media such as in enhanced oil recovery and the breaking of emulsions in porous coalescers. With regard to examples of studies on the creeping motion of droplets in a flow through a tube, Hetsroni G. et al.[1] theoretically examined the motion of a spherical droplet or bubble with small d/D, where d is the undeformed diameter of the droplet or bubble, and D is the tube diameter. Higdon J.J.L. and Muldowney G.P. [2] numerically obtained the resistance functions for a spherical particle, droplet, and bubble. Olbricht, W.L. and Kung D.M.[3] and Aul R.W. and Olbricht, W.L.[4] mainly investigated the coalescence time of droplets. Aul R.W. and Olbricht W.L. proposed a semi-theoretical formula of the coalescence time. Based on the formula by them, Muraoka, M. et al.[5] proposed other semi-theoretical formulas of the coalescence time in terms of the resistance experienced by the liquid droplet in creeping flow through a tube. The latter formulas take the eccentricity of the following droplets into consideration. In the present study, a glass tube of inner diameter 2.0mm, outer diameter 7.0mm, and length 1500 mm was used as the test tube. Silicon oil with a kinematic viscosity of 3000cSt was employed as the test fluid of the droplet. A mixture of glycerol and pure water was used as the surrounding fluid of the creeping flow through a tube. A large volumetric syringe pump was used to maintain steady flow through the tube at a designated average velocity. The test tube was immersed in temperature-controlled water contained in a tank to maintain constant temperature of the system. The droplets were injected into the test tube. The behaviors of the droplets were monitored by a

  16. Numerical Modeling of Interstitial Fluid Flow Coupled with Blood Flow through a Remodeled Solid Tumor Microvascular Network.

    Science.gov (United States)

    Soltani, M; Chen, P

    2013-01-01

    Modeling of interstitial fluid flow involves processes such as fluid diffusion, convective transport in extracellular matrix, and extravasation from blood vessels. To date, majority of microvascular flow modeling has been done at different levels and scales mostly on simple tumor shapes with their capillaries. However, with our proposed numerical model, more complex and realistic tumor shapes and capillary networks can be studied. Both blood flow through a capillary network, which is induced by a solid tumor, and fluid flow in tumor's surrounding tissue are formulated. First, governing equations of angiogenesis are implemented to specify the different domains for the network and interstitium. Then, governing equations for flow modeling are introduced for different domains. The conservation laws for mass and momentum (including continuity equation, Darcy's law for tissue, and simplified Navier-Stokes equation for blood flow through capillaries) are used for simulating interstitial and intravascular flows and Starling's law is used for closing this system of equations and coupling the intravascular and extravascular flows. This is the first study of flow modeling in solid tumors to naturalistically couple intravascular and extravascular flow through a network. This network is generated by sprouting angiogenesis and consisting of one parent vessel connected to the network while taking into account the non-continuous behavior of blood, adaptability of capillary diameter to hemodynamics and metabolic stimuli, non-Newtonian blood flow, and phase separation of blood flow in capillary bifurcation. The incorporation of the outlined components beyond the previous models provides a more realistic prediction of interstitial fluid flow pattern in solid tumors and surrounding tissues. Results predict higher interstitial pressure, almost two times, for realistic model compared to the simplified model.

  17. Numerical Modeling of Interstitial Fluid Flow Coupled with Blood Flow through a Remodeled Solid Tumor Microvascular Network.

    Directory of Open Access Journals (Sweden)

    M Soltani

    Full Text Available Modeling of interstitial fluid flow involves processes such as fluid diffusion, convective transport in extracellular matrix, and extravasation from blood vessels. To date, majority of microvascular flow modeling has been done at different levels and scales mostly on simple tumor shapes with their capillaries. However, with our proposed numerical model, more complex and realistic tumor shapes and capillary networks can be studied. Both blood flow through a capillary network, which is induced by a solid tumor, and fluid flow in tumor's surrounding tissue are formulated. First, governing equations of angiogenesis are implemented to specify the different domains for the network and interstitium. Then, governing equations for flow modeling are introduced for different domains. The conservation laws for mass and momentum (including continuity equation, Darcy's law for tissue, and simplified Navier-Stokes equation for blood flow through capillaries are used for simulating interstitial and intravascular flows and Starling's law is used for closing this system of equations and coupling the intravascular and extravascular flows. This is the first study of flow modeling in solid tumors to naturalistically couple intravascular and extravascular flow through a network. This network is generated by sprouting angiogenesis and consisting of one parent vessel connected to the network while taking into account the non-continuous behavior of blood, adaptability of capillary diameter to hemodynamics and metabolic stimuli, non-Newtonian blood flow, and phase separation of blood flow in capillary bifurcation. The incorporation of the outlined components beyond the previous models provides a more realistic prediction of interstitial fluid flow pattern in solid tumors and surrounding tissues. Results predict higher interstitial pressure, almost two times, for realistic model compared to the simplified model.

  18. Liquid-metal flow through a thin-walled elbow in a plane perpendicular to a uniform magnetic field

    International Nuclear Information System (INIS)

    Walker, J.S.

    1986-04-01

    This paper presents analytical solutions for the liquid-metal flow through two straight pipes connected by a smooth elbow with the same inside radius. The pipes and the elbow lie in a plane which is perpendicular to a uniform, applied magnetic field. The strength of the magnetic field is assumed to be sufficiently strong that inertial and viscous effects are negligible. This assumption is appropriate for the liquid-lithium flow in the blanket of a magnetic confinement fusion reactor, such as a tokamak. The pipes and the elbow have thin metal walls

  19. New model and field data on estimates of Antarctic Bottom Water flow through the deep Vema Channel

    Science.gov (United States)

    Frey, D. I.; Fomin, V. V.; Diansky, N. A.; Morozov, E. G.; Neiman, V. G.

    2017-05-01

    We used a numerical model of the ocean circulation with a high spatial resolution to obtain estimates of the kinematic characteristics of Antarctic Bottom Water flow through the abyssal Vema Channel in the southwestern part of the Atlantic Ocean. The results of simulations correspond to the data of direct velocity measurements made at several locations in the channel. The high horizontal and vertical resolution of the model in the bottom layer allowed us to study in detail the hydrodynamics of this flow over its entire length.

  20. The monitoring of methane fermentation in sequencing batch bioreactor with flow-through array of miniaturized solid state electrodes.

    Science.gov (United States)

    Buczkowska, Agnieszka; Witkowska, Emilia; Górski, Lukasz; Zamojska, Anna; Szewczyk, Krzysztof W; Wróblewski, Wojciech; Ciosek, Patrycja

    2010-06-15

    Electronic tongues (ETs) based on potentiometric sensor arrays are often used for foodstuff classification, origin recognition, estimation of complex samples' properties, etc. In the last few years they were also applied for various fermentation monitoring, such as Aspergillus niger fermentation, light cheese production, batch Escherichia coli fermentation, as a devices capable of fast, inexpensive, automated and on-line control of the process. In this work a novel application for ET is proposed-flow-through array of solid state electrodes was used for the analysis of samples obtained during methane fermentation (anaerobic digestion) of whey in sequencing batch bioreactor, according to their volatile fatty acid (VFA) content and chemical oxygen demand (COD).

  1. Use of tracers to quantify subsurface flow through a mining pit.

    Science.gov (United States)

    Schladow, S Geoffrey; Clark, Jordan F

    2008-12-01

    Three independent tracer experiments were conducted to quantify the through-flow of water from Herman Pit, an abandoned mercury (Hg) mine pit adjacent to Clear Lake, California, USA. The tracers used were Rhodamine-WT, sulfur hexafluoride, and a mixture of sulfur hexafluoride and neon-22. The tracers were injected into Herman Pit, a generally well-mixed water body of approximately 81,000 m2, and the concentrations were monitored in the mine pit, observation wells, and the lake for 2-3 months following each injection. The results for all three experiments showed that the tracer arrived at certain observation wells within days of injection. Comparing all the well data showed a highly heterogeneous response, with a small number of wells showing this near-instantaneous response and others taking months before the tracer was detectable. Tracer was also found in the lake on four occasions over a one-month period, too few to infer any pattern but sufficient to confirm the connection of the two water bodies. Using a simple mass balance model it was possible to determine the effective loss rate through advection for each of the tracers and with this to estimate the through-flow rate. The through-flow rate for all three experiments was approximately 630 L/s, at least 1-2 orders of magnitude larger than previous estimates, all of which had been based on geochemical inferences or other indirect measures of the pit through-flow.

  2. Second law analysis of water flow through smooth microtubes under adiabatic conditions

    Energy Technology Data Exchange (ETDEWEB)

    Parlak, Nezaket; Guer, Mesut; Ari, Vedat; Kuecuek, Hasan; Engin, Tahsin [The University of Sakarya, Faculty of Engineering, Department of Mechanical Engineering, Esentepe Campus, 54187 Sakarya (Turkey)

    2011-01-15

    In the study, a second law analysis for a steady-laminar flow of water in adiabatic microtubes has been conducted. Smooth microtubes with the diameters between 50 and 150 {mu}m made of fused silica were used in the experiments. Considerable temperature rises due to viscous dissipation and relatively high pressure losses of flow were observed in experiments. To identify irreversibility of flow, rate of entropy generation from the experiments have been determined in the laminar flow range of Re = 20-2200. The second law of thermodynamics was applied to predict the entropy generation. The results of model taken from the literature, proposed to predict the temperature rise caused by viscous heating, correspond well with the experimental data. The second law analysis results showed that the flow characteristics in the smooth microtubes distinguish substantially from the conventional theory for flow in the larger tubes with respect to viscous heating/dissipation (temperature rise of flow) total entropy generation rate and lost work. (author)

  3. Single-pass multi-view volume rendering

    OpenAIRE

    Hübner, T; Pajarola, R

    2007-01-01

    In this paper, we introduce a new direct volume rendering (DVR) algorithm for multi-view auto-stereoscopic displays. Common multi-view methods perform multi-pass rendering (one pass for each view) and subsequent image compositing and masking for generating multiple views. The rendering time increases therefore linearly with the number of views, but sufficient frame-rates are achieved by sub-resolution rendering, at the expense of degraded image quality. To overcome these disadvantages for DVR...

  4. Single pass kernel k-means clustering method

    Indian Academy of Sciences (India)

    2016-08-26

    Aug 26, 2016 ... Department of Computer Science and Engineering, Srinivasa Ramanujan Institute of Technology, Anantapur 515701, India; Department of Computer Science and Engineering, Rajeev Gandhi Memorial College of Engineering and Technology, Nandyal 518501, India; Department of Computer Science and ...

  5. Single pass kernel k-means clustering method

    Indian Academy of Sciences (India)

    In unsupervised classification, kernel -means clustering method has been shown to perform better than conventional -means clustering method in ... 518501, India; Department of Computer Science and Engineering, Jawaharlal Nehru Technological University, Anantapur College of Engineering, Anantapur 515002, India ...

  6. Single pass kernel k-means clustering method

    Indian Academy of Sciences (India)

    easily implemented and is suitable for large data sets, like those in data mining appli- cations. Experimental results show that, with a small loss of quality, the proposed method can significantly reduce the time taken than the conventional kernel k-means cluster- ing method. The proposed method is also compared with other ...

  7. Single pass kernel k-means clustering method

    Indian Academy of Sciences (India)

    This approach has reduced both time complexity and memory requirements. However, the clustering result of this method will be very much deviated form that obtained using the conventional kernel k-means method. This is because of the fact that pseudo cluster centers in the input space may not represent the exact cluster ...

  8. Single Pass Collider Memo: Gradient Perturbations of the SLC arc

    Energy Technology Data Exchange (ETDEWEB)

    Weng, W.T.; Sands, M.; /SLAC

    2016-12-16

    As the beam passes through the arcs, the gradient it encounters at each magnet differs from the design value. This deviation may be in part random and in part systematic. In this note we make estimates of the effects to be expected from both kinds of errors.

  9. Experimental and numerical studies of choked flow through adiabatic and diabatic capillary tubes

    International Nuclear Information System (INIS)

    Deodhar, Subodh D.; Kothadia, Hardik B.; Iyer, K.N.; Prabhu, S.V.

    2015-01-01

    Capillary tubes are extensively used in several cooling applications like refrigeration, electronic cooling etc. Local pressure variation in adiabatic straight capillary tube (mini channel) is studied experimentally and numerically with R134a as the working fluid. Experiments are performed on two straight capillary tubes. It is found that the diameter is the most sensitive design parameter of the capillary tube. Experiments are performed on five helically coiled capillary tubes to quantify the effect of pitch and curvature of helically coiled capillary tube on the pressure drop. Non dimensionalized factor to account coiling of capillary tube is derived to calculate mass flow rate in helically coiled capillary tubes. Flow visualization in adiabatic capillary tube confirms the bubbly nature of two phase flow. Numerical and experimental investigations in diabatic capillary tube suggest that the use of positive displacement pump and choking at the exit of the channel ensures flow stability. - Highlights: • Model is developed to design capillary tube in adiabatic and diabatic condition. • Effect of coil curvature on pressure drop is studied experimentally. • Correlation is developed to predict mass flow rate in helical capillary tubes. • Flow visualization is carried out to check the type of two phase flow. • Effect of choked flow on diabatic capillary tubes is studied experimentally.

  10. Freezing controlled penetration of molten metals flowing through stainless steel tubes

    International Nuclear Information System (INIS)

    Sienicki, J.J.; Spencer, B.W.; Vetter, D.L.; Wesel, R.H.

    1985-01-01

    The freezing controlled penetration potential of molten metals flowing within stainless steel structure is important to the safety assessment of hypothetical severe accidents in liquid metal reactors. A series of scoping experiments has been performed in which molten stainless steel and nickel at various initial temperatures and driving pressures were injected downward and upward into 6.4 and 3.3 mm ID stainless steel tubes filled with argon gas and initially at room temperature. In all tests, there was no evidence that the solid tube wall was wetted by the molten metals. The penetration phenomena are markedly different for downward versus upward injections. The dependency upon tube orientation is explained in terms of the absence of wetting. Complete plugs were formed in all experiments halting the continued injection of melt. Calculations with a fluid dynamics/heat transfer computer code show that the injected masses limited by plugging are consistent with freezing through the growth of a stable solidified layer (crust) of metal upon the solid tube wall. 23 refs., 5 figs., 2 tabs

  11. Effect of fluid friction on interstitial fluid flow coupled with blood flow through solid tumor microvascular network.

    Science.gov (United States)

    Sefidgar, Mostafa; Soltani, M; Raahemifar, Kaamran; Bazmara, Hossein

    2015-01-01

    A solid tumor is investigated as porous media for fluid flow simulation. Most of the studies use Darcy model for porous media. In Darcy model, the fluid friction is neglected and a few simplified assumptions are implemented. In this study, the effect of these assumptions is studied by considering Brinkman model. A multiscale mathematical method which calculates fluid flow to a solid tumor is used in this study to investigate how neglecting fluid friction affects the solid tumor simulation. The mathematical method involves processes such as blood flow through vessels and solute and fluid diffusion, convective transport in extracellular matrix, and extravasation from blood vessels. The sprouting angiogenesis model is used for generating capillary network and then fluid flow governing equations are implemented to calculate blood flow through the tumor-induced capillary network. Finally, the two models of porous media are used for modeling fluid flow in normal and tumor tissues in three different shapes of tumors. Simulations of interstitial fluid transport in a solid tumor demonstrate that the simplifications used in Darcy model affect the interstitial velocity and Brinkman model predicts a lower value for interstitial velocity than the values that Darcy model predicts.

  12. Synergistic Processing of Biphenyl and Benzoate: Carbon Flow Through the Bacterial Community in Polychlorinated-Biphenyl-Contaminated Soil.

    Science.gov (United States)

    Leewis, Mary-Cathrine; Uhlik, Ondrej; Leigh, Mary Beth

    2016-02-26

    Aerobic mineralization of PCBs, which are toxic and persistent organic pollutants, involves the upper (biphenyl, BP) and lower (benzoate, BZ) degradation pathways. The activity of different members of the soil microbial community in performing one or both pathways, and their synergistic interactions during PCB biodegradation, are not well understood. This study investigates BP and BZ biodegradation and subsequent carbon flow through the microbial community in PCB-contaminated soil. DNA stable isotope probing (SIP) was used to identify the bacterial guilds involved in utilizing (13)C-biphenyl (unchlorinated analogue of PCBs) and/or (13)C-benzoate (product/intermediate of BP degradation and analogue of chlorobenzoates). By performing SIP with two substrates in parallel, we reveal microbes performing the upper (BP) and/or lower (BZ) degradation pathways, and heterotrophic bacteria involved indirectly in processing carbon derived from these substrates (i.e. through crossfeeding). Substrate mineralization rates and shifts in relative abundance of labeled taxa suggest that BP and BZ biotransformations were performed by microorganisms with different growth strategies: BZ-associated bacteria were fast growing, potentially copiotrophic organisms, while microbes that transform BP were oligotrophic, slower growing, organisms. Our findings provide novel insight into the functional interactions of soil bacteria active in processing biphenyl and related aromatic compounds in soil, revealing how carbon flows through a bacterial community.

  13. The development of flow-through bio-catalyst microreactors from silica micro structured fibers for lipid transformations.

    Science.gov (United States)

    Anuar, Sabiqah Tuan; Villegas, Carla; Mugo, Samuel M; Curtis, Jonathan M

    2011-06-01

    This study demonstrates the utility of a flow-through enzyme immobilized silica microreactor for lipid transformations. A silica micro structured fiber (MSF) consisting of 168 channels of internal diameter 4-5 μm provided a large surface area for the covalent immobilization of Candida antartica lipase. The specific activity of the immobilized lipase was determined by hydrolysis of p-nitrophenyl butyrate and calculated to be 0.81 U/mg. The catalytic performance of the lipase microreactor was demonstrated by the efficient ethanolysis of canola oil. The parameters affecting the performance of the MSF microreactor, including temperature and reaction flow rate, were investigated. Characterization of the lipid products exiting the microreactor was performed by non-aqueous reversed-phased liquid chromatography (NARP-LC) with evaporative light scattering detector (ELSD) and by comprehensive two-dimensional gas chromatography (GC x GC). Under optimized conditions of 1 μL/min flow rate of 5 mg/mL trioleoylglycerol (TO) in ethanol and 50 °C reaction temperature, 2-monooleoylglycerol was the main product at > 90% reaction yield. The regioselectivity of the Candida antartica lipase immobilized MSF microreactor in the presence of ethanol was found to be comparable to that obtained under conventional conditions. The ability of these reusable flow-through microreactors to regioselectively form monoacylglycerides in high yield from triacylglycerides demonstrate their potential use in small-scale lipid transformations or analytical lipids profiling.

  14. X-ray computed-tomography observations of water flow through anisotropic methane hydrate-bearing sand

    Energy Technology Data Exchange (ETDEWEB)

    Seol, Yongkoo; Kneafsey, Timothy J.

    2009-06-01

    We used X-ray computed tomography (CT) to image and quantify the effect of a heterogeneous sand grain-size distribution on the formation and dissociation of methane hydrate, as well as the effect on water flow through the heterogeneous hydrate-bearing sand. A 28 cm long sand column was packed with several segments having vertical and horizontal layers with sands of different grain-size distributions. During the hydrate formation, water redistribution occurred. Observations of water flow through the hydrate-bearing sands showed that water was imbibed more readily into the fine sand, and that higher hydrate saturation increased water imbibition in the coarse sand due to increased capillary strength. Hydrate dissociation induced by depressurization resulted in different flow patterns with the different grain sizes and hydrate saturations, but the relationships between dissociation rates and the grain sizes could not be identified using the CT images. The formation, presence, and dissociation of hydrate in the pore space dramatically impact water saturation and flow in the system.

  15. Food web flows through a sub-arctic deep-sea benthic community

    Science.gov (United States)

    Gontikaki, E.; van Oevelen, D.; Soetaert, K.; Witte, U.

    2011-11-01

    The benthic food web of the deep Faroe-Shetland Channel (FSC) was modelled by using the linear inverse modelling methodology. The reconstruction of carbon pathways by inverse analysis was based on benthic oxygen uptake rates, biomass data and transfer of labile carbon through the food web as revealed by a pulse-chase experiment. Carbon deposition was estimated at 2.2 mmol C m -2 d -1. Approximately 69% of the deposited carbon was respired by the benthic community with bacteria being responsible for 70% of the total respiration. The major fraction of the labile detritus flux was recycled within the microbial loop leaving merely 2% of the deposited labile phytodetritus available for metazoan consumption. Bacteria assimilated carbon at high efficiency (0.55) but only 24% of bacterial production was grazed by metazoans; the remaining returned to the dissolved organic matter pool due to viral lysis. Refractory detritus was the basal food resource for nematodes covering ∼99% of their carbon requirements. On the contrary, macrofauna seemed to obtain the major part of their metabolic needs from bacteria (49% of macrofaunal consumption). Labile detritus transfer was well-constrained, based on the data from the pulse-chase experiment, but appeared to be of limited importance to the diet of the examined benthic organisms (preferred prey, in this case, was other macrofaunal animals rather than nematodes. Bacteria and detritus contributed 53% and 12% to the total carbon ingestion of carnivorous polychaetes suggesting a high degree of omnivory among higher consumers in the FSC benthic food web. Overall, this study provided a unique insight into the functioning of a deep-sea benthic community and demonstrated how conventional data can be exploited further when combined with state-of-the-art modelling approaches.

  16. Visualization of Colloid Deposition and Mobilization During Unsteady and Steady Porewater Flow Through Unsaturated Porous Media.

    Science.gov (United States)

    Saiers, J. E.; Gao, B.; Ryan, J. N.

    2004-12-01

    Mineral colloids that are mobilized from near-surface soils during infiltration events may carry sorptive contaminants through the vadose zone and into drinking-water aquifers. The vadose-zone flux of colloid-associated contaminants depends, in part, on the difference between colloid mobilization rates and deposition rates. Our research is aimed at improving current understanding of colloid effects on subsurface-contaminant transport by identifying the mechanisms that govern colloid mobilization and deposition in unsaturated porous media. We present pore-scale observations of the transport of fluorescent microspheres through transparent flow cells packed with a thin layer of partially saturated sand. These visualization experiments were conducted under steady-flow and transient-flow conditions. In experiments in which the air phase was discontinuous and occurred as insular air bubbles, the negatively charged microspheres accumulated at the air-bubble surface and moved freely about this air-water interface. A fraction of these colloids eventually migrated from the air-water interface to the air-water-solid interface, whereupon their motion stopped. Destruction of the air bubbles during imbibition led to the release of colloids retained previously by the air-water interface, but not to the release of colloids held at the air-water-solid interface. Colloids were also trapped upon entry into dead-end water conduits that split from the primary flow channels. The exchange of colloids and water between a dead zone and primary flow channel was slow under steady flow; however, the reconnection of dead-end zones as moisture content increased during imbibition resulted in the mobilization of large concentrations of colloids. Our findings show that multiple mechanisms govern the deposition and mobilization of colloids in unsaturated porous media and provide direction for refining mathematical models for colloid and colloid-facilitated contaminant transport within the vadose

  17. Kinematics and statistics of dense, slow granular flow through vertical channels

    Science.gov (United States)

    Ananda, K. S.; Moka, Sudheshna; Nott, Prabhu R.

    We have investigated the flow of dry granular materials through vertical channels in the regime of dense slow flow using video imaging of the particles adjacent to a transparent wall. Using an image processing technique based on particle tracking velocimetry, the video movies were analysed to obtain the velocities of individual particles. Experiments were conducted in two- and three-dimensional channels. In the latter, glass beads and mustard seeds were used as model granular materials, and their translational velocities were measured. In the former, aluminium disks with a dark diametral stripe were used and their translational velocities and spin were measured. Experiments in the three-dimensional channels were conducted for a range of the channel width W, and for smooth and rough sidewalls. As in earlier studies, we find that shearing takes place predominantly in thin layers adjacent to the walls, while the rest of the material appears to move as a plug. However, there are large velocity fluctuations even in the plug, where the macroscopic deformation rate is negligibly small. The thickness of the shear layer, scaled by the particle diameter dp, increases weakly with W/dp. The experimental data for the velocity field are in good agreement with the Cosserat plasticity model proposed recently. We also measured the mean spin of the particles in the two-dimensional channel, and its deviation from half the vorticity. There is a clear, measurable deviation, which too is in qualitative agreement with the Cosserat plasticity model. The statistics of particle velocity and spin fluctuations in the two-dimensional channel were analysed by determining their probability distribution function, and their spatial and temporal correlation. They were all found to be broadly similar to previous observations for three-dimensional channels, but some differences are evident. The spatial correlation of the velocity fluctuations are much stronger in the two-dimensional channel, implying

  18. Visualization study of helium-air counter flow through a small opening

    International Nuclear Information System (INIS)

    Fumizawa, Motoo

    2007-01-01

    Buoyancy-driven counter flows of helium-air were investigated through horizontal and inclined small openings. Counter flows may occur following a window opening as ventilation, fire in the room as well as a pipe rupture accident in a high temperature gas-cooled nuclear reactor. The experiment has carried out by a test chamber filled with helium and flow was visualized by the smoke wire method. The flow behavior has recorded by a high-speed camera with a computer system. The image of the flow was transferred to the digital data, thus the flow velocity was measured by PTV software. The mass fraction in the test chamber was measured by electronic balance. The detected data was arranged by the densimetric Floude number of the counter flow rate that derived from the dimensional analysis. The method of mass increment was developed and applied to measure the counter flow rate. By removing the cover plate placed on the top of the opening, the counter flow initiated. Air enters the test chamber and the mass of the gas mixture in the test chamber increased. The volumetric counter flow rate was evaluated from the mass increment data. In the case of inclination openings, the results of both methods were compared. The inclination angle for maximum densimetric Floude number decreased with increasing length-to-diameter ratio of the opening. For a horizontal opening, the results from the method of mass increment agreed with those obtained by other authors for a water-brine system. (author)

  19. Video imaging measurement of interfacial wave velocity in air-water flow through a horizontal elbow

    Science.gov (United States)

    Al-Wazzan, Amir; Than, Cheok F.; Moghavvemi, Mahmoud; Yew, Chia W.

    2001-10-01

    Two-phase flow in pipelines containing elbows represents a common situation in the oil and gas industries. This study deals with the stratified flow regime between the gas and liquid phase through an elbow. It is of interest to study the change in wave characteristics by measuring the wave velocity and wavelength at the inlet and outlet of the elbow. The experiments were performed under concurrent air-water stratified flow in a horizontal transparent polycarbonate pipe of 0.05m diameter and superficial air and water velocities up to 8.97 and 0.0778 m/s respectively. A non-intrusive video imaging technique was applied to capture the waves. For image analysis, a frame by frame direct overlapping method was used to detect for pulsating flow and a pixel shifting method based on the detection of minimum values in the overlap function was used to determine wave velocity and wavelength. Under superficial gas velocity of less than 4.44 m/s, the results suggest a regular pulsating outflow produced by the elbow. At higher gas velocities, more random pulsation was found and the emergence of localized interfacial waves was detected. Wave velocities measured by this technique were found to produce satisfactory agreement with direct measurements.

  20. Partially to fully saturated flow through smooth, clean, open fractures: qualitative experimental studies

    Science.gov (United States)

    Jones, Brendon R.; Brouwers, Luke B.; Dippenaar, Matthys A.

    2018-05-01

    Fractures are both rough and irregular but can be expressed by a simple model concept of two smooth parallel plates and the associated cubic law governing discharge through saturated fractures. However, in natural conditions and in the intermediate vadose zone, these assumptions are likely violated. This paper presents a qualitative experimental study investigating the cubic law under variable saturation in initially dry free-draining discrete fractures. The study comprised flow visualisation experiments conducted on transparent replicas of smooth parallel plates with inlet conditions of constant pressure and differing flow rates over both vertical and horizontal inclination. Flow conditions were altered to investigate the influence of intermittent and continuous influx scenarios. Findings from this research proved, for instance, that saturated laminar flow is not likely achieved, especially in nonhorizontal fractures. In vertical fractures, preferential flow occupies the minority of cross-sectional area despite the water supply. Movement of water through the fractured vadose zone therefore becomes a matter of the continuity principle, whereby water should theoretically be transported downward at significantly higher flow rates given the very low degree of water saturation. Current techniques that aim to quantify discrete fracture flow, notably at partial saturation, are questionable. Inspired by the results of this study, it is therefore hypothetically improbable to achieve saturation in vertical fractures under free-draining wetting conditions. It does become possible under extremely excessive water inflows or when not free-draining; however, the converse is not true, as a wet vertical fracture can be drained.

  1. Experimental investigation on the transient one phase flow through perforated plates

    International Nuclear Information System (INIS)

    Casadei, F.; Dalle Donne, M.

    1982-01-01

    The coolant flow across the perforated dip-plate during a HCDA in a LMFBR was simulated in a one-dimensional model. Several experiments with water as fluid and with various perforation ratios of the dip-plate and different initial heights of the fluid head over the dip-plate were run. The pressure drop across the dip-plate and the forces acting on the dip-plate and on the upper plug of the reactor vessel were measured in a wide range of the Reynolds and Strouhal numbers. The flow pattern downstreams the perforated plate was filmed with high-speed cameras. The resistance coefficients for the transient flow of the coolant through the perforated plate were obtained as a function of the acceleration. The forces acting on the upper plug and their time integral were compared with those acting on the dip-plate. Finally, using high-speed film pictures the formation of fluid jets downstream the dip-plate was investigated

  2. Numerical study on flow rate limitation of open capillary channel flow through a wedge

    Directory of Open Access Journals (Sweden)

    Ting-Ting Zhang

    2016-04-01

    Full Text Available The flow characteristics of slender-column flow in wedge-shaped channel under microgravity condition are investigated in this work. The one-dimensional theoretical model is applied to predict the critical flow rate and surface contour of stable flow. However, the one-dimensional model overestimates the critical flow rate for not considering the extra pressure loss. Then, we develop a three-dimensional simulation method with OpenFOAM, a computational fluid dynamics tool, to simulate various phenomena in wedge channels with different lengths. The numerical results are verified with the capillary channel flow experimental data on the International Space Station. We find that the three-dimensional simulation perfectly predicts the critical flow rates and surface contours under various flow conditions. Meanwhile, the general behaviors in subcritical, critical, and supercritical flow are studied in three-dimensional simulation considering variations of flow rate and open channel length. The numerical techniques for three-dimensional simulation is validated for a wide range of configurations and is hopeful to provide valuable guidance for capillary channel flow experiment and efficient liquid management in space.

  3. Partially to fully saturated flow through smooth, clean, open fractures: qualitative experimental studies

    Science.gov (United States)

    Jones, Brendon R.; Brouwers, Luke B.; Dippenaar, Matthys A.

    2017-11-01

    Fractures are both rough and irregular but can be expressed by a simple model concept of two smooth parallel plates and the associated cubic law governing discharge through saturated fractures. However, in natural conditions and in the intermediate vadose zone, these assumptions are likely violated. This paper presents a qualitative experimental study investigating the cubic law under variable saturation in initially dry free-draining discrete fractures. The study comprised flow visualisation experiments conducted on transparent replicas of smooth parallel plates with inlet conditions of constant pressure and differing flow rates over both vertical and horizontal inclination. Flow conditions were altered to investigate the influence of intermittent and continuous influx scenarios. Findings from this research proved, for instance, that saturated laminar flow is not likely achieved, especially in nonhorizontal fractures. In vertical fractures, preferential flow occupies the minority of cross-sectional area despite the water supply. Movement of water through the fractured vadose zone therefore becomes a matter of the continuity principle, whereby water should theoretically be transported downward at significantly higher flow rates given the very low degree of water saturation. Current techniques that aim to quantify discrete fracture flow, notably at partial saturation, are questionable. Inspired by the results of this study, it is therefore hypothetically improbable to achieve saturation in vertical fractures under free-draining wetting conditions. It does become possible under extremely excessive water inflows or when not free-draining; however, the converse is not true, as a wet vertical fracture can be drained.

  4. Transient Flow through an Unsaturated Levee Embankment during the 2011 Mississippi River Flood

    Science.gov (United States)

    Jafari, N.; Stark, T.; Vahedifard, F.; Cadigan, J.

    2017-12-01

    The Mississippi River and corresponding tributaries drain approximately 3.23 million km2 (1.25 million mi2) or the equivalent of 41% of the contiguous United States. Approximately 2,600 km ( 1,600 miles) of earthen levees presently protect major urban cities and agricultural land against the periodic Mississippi River floods within the Lower Mississippi River Valley. The 2011 flood also severely stressed the levees and highlighted the need to evaluate the behavior of levee embankments during high water levels. The performance of earthen levees is complex because of the uncertainties in construction materials, antecedent moisture contents, hydraulic properties, and lack of field monitoring. In particular, calibration of unsaturated and saturated soil properties of levee embankment and foundation layers along with the evaluation of phreatic surface during high river stage is lacking. Due to the formation of sand boils at the Duncan Point Levee in Baton Rouge, LA during the 2011 flood event, a reconnaissance survey was conducted to collect pore-water pressures in the sand foundation using piezometers and identifying the phreatic surface at the peak river level. Transient seepage analyses were performed to calibrate the foundation and levee embankment material properties using field data collected. With this calibrated levee model, numerical experiments were conducted to characterize the effects of rainfall intensity and duration, progression of phreatic surface, and seasonal climate variability prior to floods on the performance of the levee embankment. For example, elevated phreatic surface from river floods are maintained for several months and can be compounded with rainfall to lead to slope instability.

  5. Field, laboratory and numerical approaches to studying flow through mangrove pneumatophores

    Science.gov (United States)

    Chua, V. P.

    2014-12-01

    The circulation of water in riverine mangrove swamps is expected to be influenced by mangrove roots, which in turn affect the nutrients, pollutants and sediments transport in these systems. Field studies were carried out in mangrove areas along the coastline of Singapore where Avicennia marina and Sonneratia alba pneumatophore species are found. Geometrical properties, such as height, diameter and spatial density of the mangrove roots were assessed through the use of photogrammetric methods. Samples of these roots were harvested from mangrove swamps and their material properties, such as bending strength and Young's modulus were determined in the laboratory. It was found that the pneumatophores under hydrodynamic loadings in a mangrove environment could be regarded as fairly rigid. Artificial root models of pneumatophores were fabricated from downscaling based on field observations of mangroves. Flume experiments were performed and measurements of mean flow velocities, Reynolds stress and turbulent kinetic energy were made. The boundary layer formed over the vegetation patch is fully developed after x = 6 m with a linear mean velocity profile. High shear stresses and turbulent kinetic energy were observed at the interface between the top portion of the roots and the upper flow. The experimental data was employed to calibrate and validate three-dimensional simulations of flow in pneumatophores. The simulations were performed with the Delft3D-FLOW model, where the vegetation effect is introduced by adding a depth-distributed resistance force and modifying the k-ɛ turbulence model. The model-predicted profiles for mean velocity, turbulent kinetic energy and concentration were compared with experimental data. The model calibration is performed by adjusting the horizontal and vertical eddy viscosities and diffusivities. A skill assessment of the model is performed using statistical measures that include the Pearson correlation coefficient (r), the mean absolute error

  6. Regional Balance Model of Financial Flows through Sectoral Approaches System of National Accounts

    Directory of Open Access Journals (Sweden)

    Ekaterina Aleksandrovna Zaharchuk

    2017-03-01

    Full Text Available The main purpose of the study, the results of which are reflected in this article, is the theoretical and methodological substantiation of possibilities to build a regional balance model of financial flows consistent with the principles of the construction of the System of National Accounts (SNA. The paper summarizes the international experience of building regional accounts in the SNA as well as reflects the advantages and disadvantages of the existing techniques for constructing Social Accounting Matrix. The authors have proposed an approach to build the regional balance model of financial flows, which is based on the disaggregated tables of the formation, distribution and use of the added value of territory in the framework of institutional sectors of SNA (corporations, public administration, households. Within the problem resolution of the transition of value added from industries to sectors, the authors have offered an approach to the accounting of development, distribution and use of value added within the institutional sectors of the territories. The methods of calculation are based on the publicly available information base of statistics agencies and federal services. The authors provide the scheme of the interrelations of the indicators of the regional balance model of financial flows. It allows to coordinate mutually the movement of regional resources by the sectors of «corporation», «public administration» and «households» among themselves, and cash flows of the region — by the sectors and directions of use. As a result, they form a single account of the formation and distribution of territorial financial resources, which is a regional balance model of financial flows. This matrix shows the distribution of financial resources by income sources and sectors, where the components of the formation (compensation, taxes and gross profit, distribution (transfers and payments and use (final consumption, accumulation of value added are

  7. Dryout characteristics and flow behavior of gas-water two-phase flow through U-shaped and inverted U-shaped bends

    International Nuclear Information System (INIS)

    Takemura, T.; Roko, K.; Shiraha, M.; Midoriyama, S.

    1986-01-01

    Experimental results are presented on the flow behavior, pressure drop characteristics, and dryout characteristics by joule heating for the gas-water flow through U-shaped and inverted U-shaped tubes invertical plane. The height of the vertical straight section of the test tube is 4100 mm, and two bend radii, 116 mm and 435 mm, are chosen for the experiments. The test tubes used are of transparent acrylic resin for the flow behavior test, and of stainless steel for the other tests, inside diameter being 18 mm for the former and 18.5 mm for the latter. Flow patterns in the vertical upflow and downflow sections are shown on the diagram of the superficial gas velocity versus liquid velocity. Further, the flow behavior in the bend section is made clear in relation to flow rates of gas and liquid. The pressure drop between inlet and outlet of the test tube for the made clear in relation to flow rates of gas and liquid. The pressure drop between inlet and outlet of the test tube for the two-phase flow is shown in comparison with that for the single-phase flow of water. The threshold conditions of dryout in the bend section by joule heatig are shown on the diagram of the superficial gas velocity versus liquid velocity. The location of the dryout in the bend section is also clarified. (orig.)

  8. Creating 3D Hierarchical Carbon Architectures with Micro-, Meso-, and Macropores via a Simple Self-Blowing Strategy for a Flow-through Deionization Capacitor.

    Science.gov (United States)

    Zhao, Shanshan; Yan, Tingting; Wang, Hui; Zhang, Jianping; Shi, Liyi; Zhang, Dengsong

    2016-07-20

    In this work, 3D hierarchical carbon architectures (3DHCAs) with micro-, meso-, and macropores were prepared via a simple self-blowing strategy as highly efficient electrodes for a flow-through deionization capacitor (FTDC). The obtained 3DHCAs have a hierarchically porous structure, large accessible specific surface area (2061 m(2) g(-1)), and good wettability. The electrochemical tests show that the 3DHCA electrode has a high specific capacitance and good electric conductivity. The deionization experiments demonstrate that the 3DHCA electrodes possess a high deionization capacity of 17.83 mg g(-1) in a 500 mg L(-1) NaCl solution at 1.2 V. Moreover, the 3DHCA electrodes present a fast deionization rate in 100-500 mg L(-1) NaCl solutions at 0.8-1.4 V. The 3DHCA electrodes also present a good regeneration behavior in the reiterative regeneration test. These above factors render the 3DHCAs a promising FTDC electrode material.

  9. The verification of NAMMU using HYDROCOIN Level 1 cases 1 and 7: transient flow from a borehole and saturated flow through a shallow land disposal facility

    International Nuclear Information System (INIS)

    Herbert, A.

    1985-10-01

    The numerical accuracy of the finite-element groundwater flow code NAMMU has been verified using test cases 1 and 7 from HYDROCOIN Level 1. Case 1 compares calculated results with an analytic solution to an idealised transient borehole experiment in a porous medium with a single horizontal fracture. The numerical results are in excellent agreement with the analytic solution, both for the pressure values and for the gradients. Our use of lower-dimensional elements to represent fractures is also verified in this test case, again with excellent agreement. Case 7 involves calculating flow through an idealised shallow land disposal facility in argillaceous media, and verifies a code's ability to model the spacially varying permeabilities which would be found in the vicinity of this type of facility. Since there is no analytical solution for this case, the results from independently developed codes have been intercompared. Considerable refinement of the grid was found necessary in the neighbourhood of the concrete engineered barriers, and near the outflow. With this refinement, the results from NAMMU compared well with results from other codes participating in the HYDROCOIN project. (author)

  10. Robustness testing, using experimental design, of a flow-through dissolution method for a product where the actives have markedly differing solubility properties.

    Science.gov (United States)

    Bloomfield, M S; Butler, W C

    2000-09-25

    The use of experimental design for the robustness testing of a flow-through dissolution method (Ph Eur/USP Apparatus 4) for atovaquone, one of the drug substances in a dual-active anti-malarial tablet formulation, Malarone tablets, is described. This procedure was developed to overcome the suppression of the atovaquone solubility, caused by the presence of the co-drug proguanil hydrochloride and potential imprecision due to the poor solubility of the coating material in the basic dissolution media employed. For this testing a quarter fractional two-level factorial design was applied, assessing six factors in sixteen experiments, with a further six centre points to assess natural experimental variation. Results demonstrate that the method is robust to small changes in all the main factors evaluated at sample times of 30 min or greater. At 15 min, variations in the concentration of sodium hydroxide in the dissolution media, peristaltic pump speed and flow rate were assessed as statistically significant. This observation is a result of the initial steepness of the dissolution release curve and hence these factors are now controlled routinely in the method. Release of this poorly soluble drug is limited at the 45 min time point (Q=75%) according to pharmacopoeial guidelines. The approach may be applied for other dissolution procedures.

  11. Flow-through Bulk Optode for Spectrophotometric Determination of Thiocyanate and Its Application to Water and Saliva Analysis

    Directory of Open Access Journals (Sweden)

    José Fernández

    2006-10-01

    Full Text Available A flow-through spectrophotometric bulk optode for the flow-injectiondetermination of thiocyanate is described. As active constituents, the optode incorporatesthe lipophilized pH indicator 5-octadecanoyloxy-2-(4-nitrophenylazophenol andmethyltridodecyl ammonium chloride, dissolved in a plasticized poly(vinylchloridemembrane entrapped in a cellulose support. The optode is applied, in conjunction with theflow injection technique, to the determination of thiocyanate at pH 7.5 (TRIS/H2SO4. Thesensor is readily regenerated with a 10-2 M NaOH carrier solution. The analyticalcharacteristics of this optode with respect to thiocyanate response time, dynamicmeasurement range, reproducibility and selectivity are discussed. The proposed FI methodis applied to the determination of thiocyanate in waters from different sources and in humansaliva samples in order to distinguish between smokers and non-smokers.

  12. APPLICATION OF FLOW-THROUGH THREE-DIMENSIONAL ELECTRODES FOR REGENERATION OF PLATING IRON ELECTROLYTES: 1. MATHEMATICAL MODEL

    Directory of Open Access Journals (Sweden)

    Alexandr Kоshev

    2014-12-01

    Full Text Available The mathematical model of electrochemical processes distribution within the three-dimensional flow-through electrode for the system Fe(III/Fe(II/Fe is described in this paper, considering also the electrochemical reactions of hydrogen and molecular oxygen reduction. Possible dynamic changes in the parameters of electrode, electrolyte and the process are taken into account in the mathematical model, such as electro-conductivity of electrode material, electrolyte flow rate, material porosity and specific electrode surface, concentrations of electro-active substances and other characteristics within the local volume of electrode. Electrode and process characteristics are treated as time and coordinate functions within the electrode volume. The results of calculations and experimental studies of iron electro-reduction are given, the analysis of the numerical modeling is provided.

  13. Peristaltic biofluids flow through vertical porous human vessels using third-grade non-Newtonian fluids model.

    Science.gov (United States)

    Akbarzadeh, Pooria

    2018-02-01

    In this paper, the heat and flow characteristic of third-grade non-Newtonian biofluids flow through a vertical porous human vessel due to peristaltic wall motion are studied. The third-grade model can describe shear thinning (or shear thickening) and normal stress differences, which is acceptable for biofluids modeling. In order to solve the governing equations, the assumption of long-wavelength approximation is utilized. This hypothesis emphasizes that the wavelength of the peristaltic wall motion is large in comparison with the radius of the human vessel, which is widely acceptable in biological investigations. The analytical perturbation method is employed to solve the governing equations. Consequently, analytical expressions for the velocity profile, shear stress, temperature field, and biofluid flow rate are obtained. In addition, the effects of the governing parameters such as the third-grade non-Newtonian parameter, Grashof Number, Eckert number, and porosity, on the results are examined.

  14. Computation of the temperatures of a fluid flowing through a pipe from temperature measurements on the pipe's outer surface

    International Nuclear Information System (INIS)

    Sauer, G.

    1999-01-01

    A method for computing the temperatures of a fluid flowing through a pipe on the basis of temperatures recorded at the pipe's outer surface is presented. The heat conduction in the pipe wall is described by one-dimensional heat conduction elements. Heat transfer between fluid, pipe and surrounding is allowed for. The equation system resulting from the standard finite element discretization is reformulated to enable the computation of temperature events preceding the recorded temperature in time. It is shown that the method can be used to identify the actual fluid temperature from temperature data obtained only at the outer surface of the pipe. The temperatures in the pipe wall are computed with good accuracy even in the case of a severe thermal shock. (orig.) [de

  15. Flow-through microdispenser for interfacing micro-HPLC to Raman and mid-IR spectroscopic detection.

    Science.gov (United States)

    Surowiec, Izabella; Baena, Josefa R; Frank, Johannes; Laurell, Thomas; Nilsson, Johan; Trojanowicz, Marek; Lendl, Bernhard

    2005-07-08

    A flow-through microdispenser has been coupled to a micro HPLC separation system and used as a solvent elimination interface for Fourier transform infrared (FTIR) and Raman spectroscopic detection of the separated compounds. Using the microdispenser picoliter sized droplets can be generated and deposited on an appropriate target placed on a computerized x, y-stage. Evaporation of volatile solvent and buffer is rapid and allows analysis of the obtained dry deposits by various techniques. Due to the destruction free character of Raman and FTIR spectroscopy they can be applied sequentially to interrogate the same deposit. In the reported application five phenolic acids typically present in wine have been separated on a C-18 column technique using a mixture of water, methanol and acetic acid as mobile phase. For spectrum acquisition infrared and Raman microscopes have been used. The spectra recorded from the dried deposits of the separated compounds agreed well with the reference spectra of corresponding components.

  16. Ice slurry flow and heat transfer during flow through tubes of rectangular and slit cross-sections

    Directory of Open Access Journals (Sweden)

    Niezgoda-Żelasko Beata

    2014-09-01

    Full Text Available The paper presents the results of experimental research of pressure drop and heat transfer coefficients of ice slurry during its flow through tubes of rectangular and slit cross-sections. Moreover, the work discusses the influence of solid particles, type of motion and cross-section on the changes in the pressure drop and heat transfer coefficient. The analysis presented in the paper allows for identification of the criterial relations used to calculate the Fanning factor and the Nusselt number for laminar and turbulent flow, taking into account elements such as phase change, which accompanies the heat transfer process. Ice slurry flow is treated as a generalized flow of a non-Newtonian fluid.

  17. Numerical simulation of turbulent flow through a straight square duct using a near wall linear k – ε model.

    Directory of Open Access Journals (Sweden)

    Ahmed Rechia

    2007-09-01

    Full Text Available The aim of this work is to predict numerically the turbulent flow through a straight square duct using Reynolds Average Navier-Stokes equations (RANS by the widely used k – ε and a near wall turbulence k – ε − fμ models. To handle wall proximity and no-equilibrium effects, the first model is modified by incorporating damping functions fμ via the eddy viscosity relation. The predicted results for the streamwise, spanwise velocities and the Reynolds stress components are compared to those given by the k – ε model and by the direct numerical simulation (DNS data of Gavrilakis (J. Fluid Mech., 1992. In light of these results, the proposed k – ε − fμ model is found to be generally satisfactory for predicting the considered flow.

  18. On-line study of growth kinetics of single hyphae of Aspergillus oryzae in a flow-through cell

    DEFF Research Database (Denmark)

    Christiansen, Torben; Spohr, Anders Bendsen; Nielsen, Jens Bredal

    1999-01-01

    Using image analysis the growth kinetics of the single hyphae of the filamentous fungus Aspergillus oryzae has been determined on-line in a flow-through cell at different glucose concentrations in the range from 26 mg L-1 to 20 g L-1. The tip extension rate of the individual hyphae can be described...... with saturation type kinetics with respect to the length of the hyphae. The maximum tip extension rate is constant for all hyphae measured at the same glucose concentration, whereas the saturation constant for the hyphae varies significantly between the hyphae even within the same hyphal element. When apical...... branching occurs, it is observed that the tip extension rate decreases temporarily. The number of branches formed on a hypha is proportional to the length of the hypha that exceeds a certain minimum length required to support the growth of a new branch. The observed kinetics has been used to simulate...

  19. A comparative CFD study on the hemodynamics of flow through an idealized symmetric and asymmetric stenosed arteries

    Science.gov (United States)

    Prashantha, B.; Anish, S.

    2017-04-01

    The aim of the present study is to numerically evaluate the hemodynamic factors which affect the formation of atherosclerosis and plaque rupture in the human artery. An increase of atherosclerosis in the artery causes geometry changes, which results in hemodynamic changes such as flow separation, reattachment and adhesion of new cells (chemotactic) in the artery. Hence, geometry plays an important role in the determining the nature of hemodynamic patterns. Influence of stenosis in the non-bifurcating artery, under pulsatile flow condition has been studied on an idealized geometry. Analysis of flow through symmetric and asymmetric stenosis in the artery revealed the significance of oscillating shear index (OSI), flow separation, low wall shear stress (WSS) zones and secondary flow patterns on plaque formation. The observed characteristic of flow in the post-stenotic region highlight the importance of plaque eccentricity on the formation of secondary stenosis on the arterial wall.

  20. On numerical model of one-dimensional time-dependent gas flows through bed of encapsulated phase change material

    Science.gov (United States)

    Lutsenko, N. A.; Fetsov, S. S.

    2017-10-01

    Mathematical model and numerical method are proposed for investigating the one-dimensional time-dependent gas flows through a packed bed of encapsulated Phase Change Material (PCM). The model is based on the assumption of interacting interpenetrating continua and includes equations of state, continuity, momentum conservation and energy for PCM and gas. The advantage of the method is that it does not require predicting the location of phase transition zone and can define it automatically as in a usual shock-capturing method. One of the applications of the developed numerical model is the simulation of novel Adiabatic Compressed Air Energy Storage system (A-CAES) with Thermal Energy Storage subsystem (TES) based on using the encapsulated PCM in packed bed. Preliminary test calculations give hope that the method can be effectively applied in the future for modelling the charge and discharge processes in such TES with PCM.

  1. Rapid and mobile determination of alcoholic strength in wine, beer and spirits using a flow-through infrared sensor

    Directory of Open Access Journals (Sweden)

    Ansay Bob

    2010-03-01

    Full Text Available Abstract Background Ever since Gay-Lussac's time, the alcoholic strength by volume (% vol has been determined by using densimetric measurements. The typical reference procedure involves distillation followed by pycnometry, which is comparably labour-intensive and therefore expensive. At present, infrared (IR spectroscopy in combination with multivariate regression is widely applied as a screening procedure, which allows one to determine alcoholic strength in less than 2 min without any sample preparation. The disadvantage is the relatively large investment for Fourier transform (FT IR or near-IR instruments, and the need for matrix-dependent calibration. In this study, we apply a much simpler device consisting of a patented multiple-beam infrared sensor in combination with a flow-through cell for automated alcohol analysis, which is available in a portable version that allows for on-site measurements. Results During method validation, the precision of the infrared sensor was found to be equal to or better than densimetric or FTIR methods. For example, the average repeatability, as determined in 6 different wine samples, was 0.05% vol and the relative standard deviation was below 0.2%. Accuracy was ensured by analyzing 260 different alcoholic beverages in comparison to densimetric or FTIR results. The correlation was linear over the entire range from alcohol-free beers up to high-proof spirits, and the results were in substantial agreement (R = 0.99981, p Conclusions The flow-through infrared device is much easier to handle than typical reference procedures, while time-consuming sample preparation steps such as distillation are not necessary. Therefore, the alcoholic strength can be economically and quickly controlled (requiring less than 60 s per sample. The device also gives the opportunity for mobile on-site control in the context of labelling control of wine, beer and spirits, the process monitoring of fermentations, or the evaluation of

  2. Rapid and mobile determination of alcoholic strength in wine, beer and spirits using a flow-through infrared sensor.

    Science.gov (United States)

    Lachenmeier, Dirk W; Godelmann, Rolf; Steiner, Markus; Ansay, Bob; Weigel, Jürgen; Krieg, Gunther

    2010-03-23

    Ever since Gay-Lussac's time, the alcoholic strength by volume (% vol) has been determined by using densimetric measurements. The typical reference procedure involves distillation followed by pycnometry, which is comparably labour-intensive and therefore expensive. At present, infrared (IR) spectroscopy in combination with multivariate regression is widely applied as a screening procedure, which allows one to determine alcoholic strength in less than 2 min without any sample preparation. The disadvantage is the relatively large investment for Fourier transform (FT) IR or near-IR instruments, and the need for matrix-dependent calibration. In this study, we apply a much simpler device consisting of a patented multiple-beam infrared sensor in combination with a flow-through cell for automated alcohol analysis, which is available in a portable version that allows for on-site measurements. During method validation, the precision of the infrared sensor was found to be equal to or better than densimetric or FTIR methods. For example, the average repeatability, as determined in 6 different wine samples, was 0.05% vol and the relative standard deviation was below 0.2%. Accuracy was ensured by analyzing 260 different alcoholic beverages in comparison to densimetric or FTIR results. The correlation was linear over the entire range from alcohol-free beers up to high-proof spirits, and the results were in substantial agreement (R = 0.99981, p unrecorded alcohol (i.e. non-commercial or illicit products). The flow-through infrared device is much easier to handle than typical reference procedures, while time-consuming sample preparation steps such as distillation are not necessary. Therefore, the alcoholic strength can be economically and quickly controlled (requiring less than 60 s per sample). The device also gives the opportunity for mobile on-site control in the context of labelling control of wine, beer and spirits, the process monitoring of fermentations, or the evaluation

  3. Choked flow through cracks

    International Nuclear Information System (INIS)

    Feburie, V.; Giot, M.; Granger, S.; Seynhaeve, J.M.

    1992-06-01

    The leaks through steam-generator cracks are the subject of a research carried out in cooperation between EDF and UCL. A software called ECREVISSE to predict the mass flow rate has been developed and has been successfully validated. The purpose of the paper is to present the mathematical model used in ECREVISSE as well as some comparison between the results and the presently available data. The model takes into account the persistence of some metastable liquid in the crack and the special flow pattern which appears in such particular geometry. Although the model involves the use of several correlations (friction, heat transfer), no adjustment of parameters against the data has been needed, neither in the single-phase part of the flow, or in the two-phase part. (authors). 8 figs., 1 tab., 20 refs

  4. Hydrocarbon Degradation in Caspian Sea Sediment Cores Subjected to Simulated Petroleum Seepage in a Newly Designed Sediment-Oil-Flow-Through System

    Directory of Open Access Journals (Sweden)

    Tina Treude

    2017-04-01

    Full Text Available The microbial community response to petroleum seepage was investigated in a whole round sediment core (16 cm length collected nearby natural hydrocarbon seepage structures in the Caspian Sea, using a newly developed Sediment-Oil-Flow-Through (SOFT system. Distinct redox zones established and migrated vertically in the core during the 190 days-long simulated petroleum seepage. Methanogenic petroleum degradation was indicated by an increase in methane concentration from 8 μM in an untreated core compared to 2300 μM in the lower sulfate-free zone of the SOFT core at the end of the experiment, accompanied by a respective decrease in the δ13C signal of methane from -33.7 to -49.5‰. The involvement of methanogens in petroleum degradation was further confirmed by methane production in enrichment cultures from SOFT sediment after the addition of hexadecane, methylnapthalene, toluene, and ethylbenzene. Petroleum degradation coupled to sulfate reduction was indicated by the increase of integrated sulfate reduction rates from 2.8 SO42-m-2 day-1 in untreated cores to 5.7 mmol SO42-m-2 day-1 in the SOFT core at the end of the experiment, accompanied by a respective accumulation of sulfide from 30 to 447 μM. Volatile hydrocarbons (C2–C6 n-alkanes passed through the methanogenic zone mostly unchanged and were depleted within the sulfate-reducing zone. The amount of heavier n-alkanes (C10–C38 decreased step-wise toward the top of the sediment core and a preferential degradation of shorter (C30 was seen during the seepage. This study illustrates, to the best of our knowledge, for the first time the development of methanogenic petroleum degradation and the succession of benthic microbial processes during petroleum passage in a whole round sediment core.

  5. Hydrocarbon Degradation in Caspian Sea Sediment Cores Subjected to Simulated Petroleum Seepage in a Newly Designed Sediment-Oil-Flow-Through System

    Science.gov (United States)

    Mishra, Sonakshi; Wefers, Peggy; Schmidt, Mark; Knittel, Katrin; Krüger, Martin; Stagars, Marion H.; Treude, Tina

    2017-01-01

    The microbial community response to petroleum seepage was investigated in a whole round sediment core (16 cm length) collected nearby natural hydrocarbon seepage structures in the Caspian Sea, using a newly developed Sediment-Oil-Flow-Through (SOFT) system. Distinct redox zones established and migrated vertically in the core during the 190 days-long simulated petroleum seepage. Methanogenic petroleum degradation was indicated by an increase in methane concentration from 8 μM in an untreated core compared to 2300 μM in the lower sulfate-free zone of the SOFT core at the end of the experiment, accompanied by a respective decrease in the δ13C signal of methane from -33.7 to -49.5‰. The involvement of methanogens in petroleum degradation was further confirmed by methane production in enrichment cultures from SOFT sediment after the addition of hexadecane, methylnapthalene, toluene, and ethylbenzene. Petroleum degradation coupled to sulfate reduction was indicated by the increase of integrated sulfate reduction rates from 2.8 SO42-m-2 day-1 in untreated cores to 5.7 mmol SO42-m-2 day-1 in the SOFT core at the end of the experiment, accompanied by a respective accumulation of sulfide from 30 to 447 μM. Volatile hydrocarbons (C2–C6 n-alkanes) passed through the methanogenic zone mostly unchanged and were depleted within the sulfate-reducing zone. The amount of heavier n-alkanes (C10–C38) decreased step-wise toward the top of the sediment core and a preferential degradation of shorter (C30) was seen during the seepage. This study illustrates, to the best of our knowledge, for the first time the development of methanogenic petroleum degradation and the succession of benthic microbial processes during petroleum passage in a whole round sediment core. PMID:28503172

  6. Vortex-induced phase slip dissipation in a torioidal Bose-Einstein condensate flowing through a barrier

    Energy Technology Data Exchange (ETDEWEB)

    Collins, Lee A [Los Alamos National Laboratory

    2009-01-01

    We study the phase slips superfluid dissipation mechanism with a BEC flowing through a repulsive barrier inside a torus. The barrier is adiabatically raised across the annulus while the condensate is flowing with a finite quantized angular momentum. We found that, at a critical height, a vortex reaches the barrier moving radially from the inner region to eventually circulate along the annulus. At a slightly higher barrier, an anti-vortex also enters into the annulus from the outward region. The vortex and anti-vortex decrease the total angular momentum by leaving behind their respective paths a 2{pi} phase slip. When they collide or orbit along the same loop, the condensate suffers a global 2{pi} phase slip and the total angular momentum decreases by one quantum. The analysis is based on numerical simulations of the dynamical Gross-Pitaevskii equation both in two- and three-dimensions, the latter with the experimental parameters of the torus trap recently created at the NIST institute.

  7. Detection of food spoilage and pathogenic bacteria based on ligation detection reaction coupled to flow-through hybridization on membranes.

    Science.gov (United States)

    Böhme, K; Cremonesi, P; Severgnini, M; Villa, Tomás G; Fernández-No, I C; Barros-Velázquez, J; Castiglioni, B; Calo-Mata, P

    2014-01-01

    Traditional culturing methods are still commonly applied for bacterial identification in the food control sector, despite being time and labor intensive. Microarray technologies represent an interesting alternative. However, they require higher costs and technical expertise, making them still inappropriate for microbial routine analysis. The present study describes the development of an efficient method for bacterial identification based on flow-through reverse dot-blot (FT-RDB) hybridization on membranes, coupled to the high specific ligation detection reaction (LDR). First, the methodology was optimized by testing different types of ligase enzymes, labeling, and membranes. Furthermore, specific oligonucleotide probes were designed based on the 16S rRNA gene, using the bioinformatic tool Oligonucleotide Retrieving for Molecular Applications (ORMA). Four probes were selected and synthesized, being specific for Aeromonas spp., Pseudomonas spp., Shewanella spp., and Morganella morganii, respectively. For the validation of the probes, 16 reference strains from type culture collections were tested by LDR and FT-RDB hybridization using universal arrays spotted onto membranes. In conclusion, the described methodology could be applied for the rapid, accurate, and cost-effective identification of bacterial species, exhibiting special relevance in food safety and quality.

  8. Detection of Food Spoilage and Pathogenic Bacteria Based on Ligation Detection Reaction Coupled to Flow-Through Hybridization on Membranes

    Directory of Open Access Journals (Sweden)

    K. Böhme

    2014-01-01

    Full Text Available Traditional culturing methods are still commonly applied for bacterial identification in the food control sector, despite being time and labor intensive. Microarray technologies represent an interesting alternative. However, they require higher costs and technical expertise, making them still inappropriate for microbial routine analysis. The present study describes the development of an efficient method for bacterial identification based on flow-through reverse dot-blot (FT-RDB hybridization on membranes, coupled to the high specific ligation detection reaction (LDR. First, the methodology was optimized by testing different types of ligase enzymes, labeling, and membranes. Furthermore, specific oligonucleotide probes were designed based on the 16S rRNA gene, using the bioinformatic tool Oligonucleotide Retrieving for Molecular Applications (ORMA. Four probes were selected and synthesized, being specific for Aeromonas spp., Pseudomonas spp., Shewanella spp., and Morganella morganii, respectively. For the validation of the probes, 16 reference strains from type culture collections were tested by LDR and FT-RDB hybridization using universal arrays spotted onto membranes. In conclusion, the described methodology could be applied for the rapid, accurate, and cost-effective identification of bacterial species, exhibiting special relevance in food safety and quality.

  9. Comparison of turbulent flow through hexagram and hexagon orifices in circular pipes using large-eddy simulation

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Wei; Nicolleau, Franck C G A; Qin, Ning, E-mail: n.qin@sheffield.ac.uk [Department of Mechanical Engineering, The University of Sheffield, Sheffield, S1 3JD (United Kingdom)

    2016-04-15

    Characteristics of turbulent flow through a circular, a hexagon and a hexagram orifice with the same flow area in circular pipes are investigated using wall-modelled large-eddy simulation. Good agreements to available experimental data were obtained in both the mean velocity and turbulent kinetic energy. The hexagram orifice with alternating convex and concave corners introduces outwards radial velocity around the concave corners downstream of the orifice plate stronger than the hexagon orifice. The stronger outwards radial velocity transfers high momentum from the pipe centre towards the pipe wall to energize the orifice-forced vortex sheet rolling-up and leads to a delayed vortex break-down. Correspondingly, the hexagram has a more gradual flow recovery to a pipe flow and a reduced pressure drop than the hexagon orifice. Both the hexagon and hexagram orifices show an axis-switching phenomenon, which is observed from both the streamwise velocity and turbulent kinetic energy contours. To the best knowledge of the authors, this is the first comparison of orifice-forced turbulence development, mixing and flow dynamics between a regular and a fractal-based polygonal orifice. (paper)

  10. The Polar Fluid Model for Blood Flow through a Tapered Artery with Overlapping Stenosis: Effects of Catheter and Velocity Slip

    Directory of Open Access Journals (Sweden)

    J. V. Ramana Reddy

    2015-01-01

    Full Text Available The blood flow through an overlapping clogged tapered artery in the presence of catheter is discussed. Since cholesterol deposition is resulting in the stenosis formation, velocity slip at the arterial wall is considered. The equations governing the fluid flow have been solved analytically under the assumption of the mild stenosis. The analysis with respect to various parameters arising out of fluid and geometry considered, on physiological parameters such as impedance and wall shear stress at the maximum height of the stenosis as well as across the entire length of the stenosis has been reported. A table summarizing the locations of extreme heights and the corresponding annular radii is provided. It is observed that the wall shear stress is the same at both the locations corresponding to the maximum height of the stenosis in case of nontapered artery while it varies in case of tapered artery. It is also observed that slip velocity and diverging tapered artery facilitate the fluid flow. Shear stress at the wall is increasing as micropolar parameter is decreasing and the trend is reversed in case of coupling number. The results obtained are validated by comparing them with the experimental and theoretical results.

  11. Hydrogen production from a rectangular horizontal filter press Divergent Electrode-Flow-Through (DEFT™) alkaline electrolysis stack

    Science.gov (United States)

    Gillespie, M. I.; Kriek, R. J.

    2017-12-01

    A membraneless Divergent Electrode-Flow-Through (DEFT™) alkaline electrolyser, for unlocking profitable hydrogen production by combining a simplistic, inexpensive, modular and durable design, capable of overcoming existing technology current density thresholds, is ideal for decentralised renewable hydrogen production, with the only requirement of electrolytic flow to facilitate high purity product gas separation. Scale-up of the technology was performed, representing a deviation from the original tested stack design, incorporating elongated electrodes housed in a filter press assembly. The pilot plant operating parameters were limited to a low flow velocity range (0.03 m s-1 -0.04 m s-1) with an electrode gap of 2.5 mm. Performance of this pilot plant demonstrated repeatability to results previously obtained. Mesh electrodes with geometric area of 344.32 cm2 were used for plant performance testing. A NiO anode and Ni cathode combination developed optimal performance yielding 508 mA cm-2 at 2 VDC in contrast to a Ni anode and cathode combination providing 467 mA cm-2 at 2.26 VDC at 0.04 m s-1, 30% KOH and 80 °C. An IrO2/RuO2/TiO2 anode and Pt cathode combination underwent catalyst deactivation. Owing to the nature of the gas/liquid separation system, gas qualities were inadequate compared to results achieved previously. Future improvements will provide qualities similar to results achieved before.

  12. Detection of Food Spoilage and Pathogenic Bacteria Based on Ligation Detection Reaction Coupled to Flow-Through Hybridization on Membranes

    Science.gov (United States)

    Böhme, K.; Cremonesi, P.; Severgnini, M.; Villa, Tomás G.; Fernández-No, I. C.; Barros-Velázquez, J.; Castiglioni, B.; Calo-Mata, P.

    2014-01-01

    Traditional culturing methods are still commonly applied for bacterial identification in the food control sector, despite being time and labor intensive. Microarray technologies represent an interesting alternative. However, they require higher costs and technical expertise, making them still inappropriate for microbial routine analysis. The present study describes the development of an efficient method for bacterial identification based on flow-through reverse dot-blot (FT-RDB) hybridization on membranes, coupled to the high specific ligation detection reaction (LDR). First, the methodology was optimized by testing different types of ligase enzymes, labeling, and membranes. Furthermore, specific oligonucleotide probes were designed based on the 16S rRNA gene, using the bioinformatic tool Oligonucleotide Retrieving for Molecular Applications (ORMA). Four probes were selected and synthesized, being specific for Aeromonas spp., Pseudomonas spp., Shewanella spp., and Morganella morganii, respectively. For the validation of the probes, 16 reference strains from type culture collections were tested by LDR and FT-RDB hybridization using universal arrays spotted onto membranes. In conclusion, the described methodology could be applied for the rapid, accurate, and cost-effective identification of bacterial species, exhibiting special relevance in food safety and quality. PMID:24818128

  13. On-line study of fungal morphology during submerged growth in a small flow-through cell

    DEFF Research Database (Denmark)

    Spohr, Anders Bendsen; Dam Mikkelsen, C.; Carlsen, Morten

    1998-01-01

    A flow-through cell is designed to measure the growth kinetics of hyphae of Aspergillus oryzae grown submerged in a well controlled environment. The different stages of the growth process are characterized, from the spore to the fully developed hyphal element with up to 60 branches and a total...... is determined. After about 10 h growth at a glucose concentration of 250 mg L-1, 6-7 branches have been set, and both the total hyphal length l(t) and the number of tips increase exponentially with time. The specific growth rate of the hyphae is 0.33 h(-1) while the average rate of the extension of the growing...... tips approaches 55 mu m h(-1). The growth kinetics for all the branches on the main hypha have also been found. The main hypha and all the branches grow at a rate which can be modeled by saturation kinetics with respect to the branch length and with nearly equal final tip speeds (160 mu m h(-1...

  14. Novel thermosyphon driven hydrothermal flow-through cell for in situ and time resolved neutron diffraction studies

    International Nuclear Information System (INIS)

    Xia, Fang; Qian, Gujie; Etschmann, Barbara; University of Adelaide, South Australia, Australia; University of Adelaide, South Australia, Australia; Studer, Andrew; Olsen, Scott

    2009-01-01

    Full text: A flow-through cell for hydrothermal phase transformation studies by in situ and time-resolved neutron diffraction has been designed and constructed. The cell has a large internal volume of 320 m L and can work at up to 300 degree Centigrade under autogeneous vapour pressures (-85 bar). The fluid flow is driven by thermosyphon which is realized by the proper design of temperature difference around the closed loop[1,2). The main body of the cell is made of stainless steel (316 type), but the sample compartment is constructed from non-scattering Ti/Zr alloy. We have successfully commissioned the cell on Australia's new high intensity powder diffractometer WOMBAT in ANSTO, using a simple transformation reaction from leucite (KAISi 2 O 6 ) to analcime (NaAISi 2 O 6H2O ) and then back from analcime to leucite. The demonstration proved that the cell is an excellent tool for probing hydrothermal phase transformations. By collecting diffraction data every 5 min, it was clearly seen that leucite was progressively transformed to analcime in a NaCI solution, and the produced analcime was progressively transformed back to leucite in a K 2 CO 3 solution.

  15. Regulation of flow through a T-Shaped open cavity by temperature dependent P, PI, and PID controllers

    International Nuclear Information System (INIS)

    Saha, Sourav; Mojumder, Satyajit; Saha, Sumon

    2016-01-01

    P (proportional), PI (proportional-integral), and PID (proportional-integral-derivative) controllers are popular means of controlling industrial processes. Due to superior response, accuracy, and stable performance, PID controllers are mostly used in control systems. This paper presents a mathematical model and subsequent response analysis regarding regulation of flow in mixed convection through a T-shaped open cavity by temperature dependent controllers. The T-shaped cavity has cold top and hot bottom walls, while air is flowing through the inlet at surrounding temperature. The inflow is regulated by a controlled gate which operates according to the signal received from the controller. Values of proportional gain (k p ), integral gain (k i ), and derivative gain (k d ) are varied to obtain the desired system response and to ensure a stable system with fastest response. At first, only P controller is used and eventually PI and finally PID control scheme is applied for controller tuning. Tuning of different controllers (P, PI, and PID) are carried out systematically based on the reference temperature which is continuously monitored at a certain location inside the cavity. It is found that PID controller performs better than P or PI controller.

  16. Preliminary results from the laboratory study of a flow-through fluorometer for measuring oil-in-water levels

    International Nuclear Information System (INIS)

    Lambert, P.; Fieldhouse, B.; Wang, Z.; Fingas, M.; Pearson, L.; Collazzi, E.

    2000-01-01

    An extensive bench-scale test program was conducted to evaluate the performance of the Turner Instruments flow-through model 10AU and model 10 fluorometers for measuring real-time concentrations of oil in water. The results were compared with alternative total petroleum hydrocarbon (TPH) methods. The 10AU model was equipped with a long wavelength optical kit, the other with the short wavelength optical kit for diesel fuels and light refined oil products. The oils tested were Alberta Sweet Mixed Blend crude oil, Prudhoe Bay crude oil, Bunker C fuel oil and diesel fuel. It was determined that the long wavelength optical kit has minimal capacity to detect and quantify diesel fuels compared to the short wavelength kit, although the latter exhibits a lower performance level. A calibration procedure was also established for oil-in-water to convert the real-time fluorometer data to oil concentrations. Initial comparisons of these tests with standard infrared and gas chromatography procedures were promising. It was determined that fluorometer data can differentiate between various oil-in-water concentrations, but regularly gives concentration values double those of the solvent extraction, infrared or gas chromatography methods. Future studies are being planned to relate the results of this study to the chemical composition of various oils. 16 refs., 5 tabs., 6 figs

  17. Numerical Simulation of Three-Dimensional Flow Through Full Passage and Performance Prediction of Nuclear Reactor Coolant Pump

    International Nuclear Information System (INIS)

    Li Ying; Zhou Wenxia; Zhang Jige; Wang Dezhong

    2009-01-01

    In order to achieve the level of self-design and domestic manufacture of the reactor coolant pump (nuclear main pump), the software FLUENT was used to simulate the three-dimensional flow through full passage of one nuclear main pump basing on RNG κ-ε turbulence model and SIMPLE algorithm. The distribution of pressure and velocity of the flow in the impeller's surface was analyzed in different working conditions. Moreover, the performance of the pump was predicted based on the simulation results. The results show that the distributions of pressure and velocity are reasonable in both the working and back face of the blade in the steady working condition. The pressure of the flow is increased from the inlet to the outlet of the pump, and shows the maximal value in the impeller region. Comparatively satisfactory efficiency and head value were obtained in the condition of the pump design. The shaft power of the nuclear main pump is gradually increased with the increase of the flow flux. These results are helpful in understanding the change of the internal flow field in the nuclear main pump, which is of some importance for the pre-exploration and theoretical research on the domestic manufacture of the nuclear main pump. (authors)

  18. Enhanced water vapour flow in silica microchannels and interdiffusive water vapour flow through anodic aluminium oxide (AAO) membranes

    Science.gov (United States)

    Lei, Wenwen; McKenzie, David R.

    2015-12-01

    Enhanced liquid water flows through carbon nanotubes reinvigorated the study of moisture permeation through membranes and micro- and nano-channels. The study of water vapour through micro-and nano-channels has been neglected even though water vapour is as important as liquid water for industry, especially for encapsulation of electronic devices. Here we measure moisture flow rates in silica microchannels and interdiffusive water vapour flows in anodic aluminium oxide (AAO) membrane channels for the first time. We construct theory for the flow rates of the dominant modes of water transport through four previously defined standard configurations and benchmark it against our new measurements. The findings show that measurements of leak behaviour made using other molecules, such as helium, are not reliable. Single phase water vapour flow is overestimated by a helium measurement, while Washburn or capillary flow is underestimated or for all channels when boundary slip applies, to an extent that depends on the slip length for the liquid phase flows.

  19. Regulation of flow through a T-Shaped open cavity by temperature dependent P, PI, and PID controllers

    Energy Technology Data Exchange (ETDEWEB)

    Saha, Sourav, E-mail: ssaha09@me.buet.ac.bd; Mojumder, Satyajit, E-mail: satyajit@me.buet.ac.bd; Saha, Sumon, E-mail: sumonsaha@me.buet.ac.bd [Department of Mechanical Engineering, Bangladesh University of Engineering and Technology, Dhaka-1000 (Bangladesh)

    2016-07-12

    P (proportional), PI (proportional-integral), and PID (proportional-integral-derivative) controllers are popular means of controlling industrial processes. Due to superior response, accuracy, and stable performance, PID controllers are mostly used in control systems. This paper presents a mathematical model and subsequent response analysis regarding regulation of flow in mixed convection through a T-shaped open cavity by temperature dependent controllers. The T-shaped cavity has cold top and hot bottom walls, while air is flowing through the inlet at surrounding temperature. The inflow is regulated by a controlled gate which operates according to the signal received from the controller. Values of proportional gain (k{sub p}), integral gain (k{sub i}), and derivative gain (k{sub d}) are varied to obtain the desired system response and to ensure a stable system with fastest response. At first, only P controller is used and eventually PI and finally PID control scheme is applied for controller tuning. Tuning of different controllers (P, PI, and PID) are carried out systematically based on the reference temperature which is continuously monitored at a certain location inside the cavity. It is found that PID controller performs better than P or PI controller.

  20. Numerical simulation of the flow through a compressor-valve model using an immersed-boundary method

    Directory of Open Access Journals (Sweden)

    Franco Barbi

    2016-01-01

    Full Text Available Hermetic reciprocating compressors are widely used in small- and medium-size refrigeration systems based on the vapor-compression cycle. One of the main parts of this type of compressor is the automatic valve system used to control the suction and discharge processes. As the suction and discharge losses represent a large amount of the total thermodynamic losses (47%, a small improvement in the suction and discharge processes can produce expressive increases in the thermodynamic efficiency of the compressor. In this work, a new numerical methodology is applied to solve the flow through reed-type valves. The numerical results were experimentally validated through the pressure distribution acting on the frontal disk of a radial diffuser, which is a geometry usually used to model this type of valve. The numerical results for the velocity and pressure fields were comprehensively explored during the opening and closing movement imposed to the reed. The good quality of these results show that the numerical methodology is very promising in terms of solving the flow in the actual dynamics of reed-type valves.

  1. Characterization of the frictional losses and heat transfer of oscillatory viscous flow through wire-mesh regenerators

    Directory of Open Access Journals (Sweden)

    A.A. Boroujerdi

    2015-12-01

    Full Text Available In this paper, new relations for calculating heat transfer and pressure drop characteristics of oscillatory flow through wire-mesh screen regenerator such as Darcy permeability, Forchheimer’s inertial coefficient, and heat transfer area per unit volume, as a function of the wire diameter are presented. According to the derived relations, thinner wires have higher pressure drop and higher heat transfer rate. The relations are applicable for all regenerative cryocoolers. Embedding the new relations into a numerical model, three Stirling-type orifice pulse tube cryocoolers with three regenerators different in length and diameter but same volume in a variety of wire diameters, have been modeled. The results achieved by the model reveal that the local heat transfer coefficient decreases with increase of the wire diameter and the length-to-diameter ratio. In addition, it was shown that the mean absolute gas–solid wire temperature difference is a linear function of wire diameter in the range investigated. The results show that for larger length-to-diameter ratios, Forchheimer’s effect will dominate frictional losses, and the variations of the frictional losses are proportional to the inverse of the wire diameter. Wire diameter has been optimized to maximize the coefficient of performance of the cryocooler. Shorter regenerators have thinner optimum wires.

  2. Micro Droplets of non-Newtonian Solutions in Silicone Oil Flow through a Hydrophobic Micro Cross-Junction

    Science.gov (United States)

    Rostami, B.; Morini, G. L.

    2017-11-01

    In this paper the generation of non-Newtonian droplets of aqueous Xanthan gum solution (0.3, 0.5 wt%) in a silicone oil flow through a micro cross-junction is experimentally analyzed. A commercial glass cross-junction microchip with hydrophobic walls has been employed to study the droplet generation mechanism. The cross-section of the channel is stadium-shaped, the width of the junction varies between 195 to 390 μm while the height of the channel is fixed at 190 μm. Tween 20 (2 wt%), as a surfactant, has been added to the dispersed phase to avoid the coalescence of the droplets and to enhance the droplet formation. With the aim to follow the time evolution of the droplets inside the channel a specific experimental setup has been implemented. The post-processing of the recorded images has been carried out by means of an “in-house” Matlab code. The typical flow patterns obtained by imposing different flow rates at the inlets of the cross-junction have been observed. The effect of the continuous and dispersed phase flow rates as well as the concentration of Xanthan gum solution on the main droplet characteristics has been studied in detail.

  3. Regulation of flow through a T-Shaped open cavity by temperature dependent P, PI, and PID controllers

    Science.gov (United States)

    Saha, Sourav; Mojumder, Satyajit; Saha, Sumon

    2016-07-01

    P (proportional), PI (proportional-integral), and PID (proportional-integral-derivative) controllers are popular means of controlling industrial processes. Due to superior response, accuracy, and stable performance, PID controllers are mostly used in control systems. This paper presents a mathematical model and subsequent response analysis regarding regulation of flow in mixed convection through a T-shaped open cavity by temperature dependent controllers. The T-shaped cavity has cold top and hot bottom walls, while air is flowing through the inlet at surrounding temperature. The inflow is regulated by a controlled gate which operates according to the signal received from the controller. Values of proportional gain (kp), integral gain (ki), and derivative gain (kd) are varied to obtain the desired system response and to ensure a stable system with fastest response. At first, only P controller is used and eventually PI and finally PID control scheme is applied for controller tuning. Tuning of different controllers (P, PI, and PID) are carried out systematically based on the reference temperature which is continuously monitored at a certain location inside the cavity. It is found that PID controller performs better than P or PI controller.

  4. CFD simulation of an internal spin-filter: evidence of lateral migration and exchange flow through the mesh.

    Science.gov (United States)

    Figueredo-Cardero, Alvio; Chico, Ernesto; Castilho, Leda R; Medronho, Ricardo A

    2009-11-01

    In the present work Computational Fluid Dynamics (CFD) was used to study the flow field and particle dynamics in an internal spin-filter (SF) bioreactor system. Evidence of a radial exchange flow through the filter mesh was detected, with a magnitude up to 130-fold higher than the perfusion flow, thus significantly contributing to radial drag. The exchange flow magnitude was significantly influenced by the filter rotation rate, but not by the perfusion flow, within the ranges evaluated. Previous reports had only given indirect evidences of this exchange flow phenomenon in spin-filters, but the current simulations were able to quantify and explain it. Flow pattern inside the spin-filter bioreactor resembled a typical Taylor-Couette flow, with vortices being formed in the annular gap and eventually penetrating the internal volume of the filter, thus being the probable reason for the significant exchange flow observed. The simulations also showed that cells become depleted in the vicinity of the mesh due to lateral particle migration. Cell concentration near the filter was approximately 50% of the bulk concentration, explaining why cell separation achieved in SFs is not solely due to size exclusion. The results presented indicate the power of CFD techniques to study and better understand spin-filter systems, aiming at the establishment of effective design, operation and scale-up criteria.

  5. Assessing honeybee and wasp thermoregulation and energetics-New insights by combination of flow-through respirometry with infrared thermography.

    Science.gov (United States)

    Stabentheiner, Anton; Kovac, Helmut; Hetz, Stefan K; Käfer, Helmut; Stabentheiner, Gabriel

    2012-04-20

    Endothermic insects like honeybees and some wasps have to cope with an enormous heat loss during foraging because of their small body size in comparison to endotherms like mammals and birds. The enormous costs of thermoregulation call for optimisation. Honeybees and wasps differ in their critical thermal maximum, which enables the bees to kill the wasps by heat. We here demonstrate the benefits of a combined use of body temperature measurement with infrared thermography, and respiratory measurements of energy turnover (O(2) consumption or CO(2) production via flow-through respirometry) to answer questions of insect ecophysiological research, and we describe calibrations to receive accurate results.To assess the question of what foraging honeybees optimise, their body temperature was compared with their energy turnover. Honeybees foraging from an artificial flower with unlimited sucrose flow increased body surface temperature and energy turnover with profitability of foraging (sucrose content of the food; 0.5 or 1.5 mol/L). Costs of thermoregulation, however, were rather independent of ambient temperature (13-30 °C). External heat gain by solar radiation was used to increase body temperature. This optimised foraging energetics by increasing suction speed.In determinations of insect respiratory critical thermal limits, the combined use of respiratory measurements and thermography made possible a more conclusive interpretation of respiratory traces.

  6. The effect of deformation on two-phase flow through proppant-packed fractured shale samples: A micro-scale experimental investigation

    Science.gov (United States)

    Arshadi, Maziar; Zolfaghari, Arsalan; Piri, Mohammad; Al-Muntasheri, Ghaithan A.; Sayed, Mohammed

    2017-07-01

    We present the results of an extensive micro-scale experimental investigation of two-phase flow through miniature, fractured reservoir shale samples that contained different packings of proppant grains. We investigated permeability reduction in the samples by conducting experiments under a wide range of net confining pressures. Three different proppant grain distributions in three individual fractured shale samples were studied: i) multi-layer, ii) uniform mono-layer, and iii) non-uniform mono-layer. We performed oil-displacing-brine (drainage) and brine-displacing-oil (imbibition) flow experiments in the proppant packs under net confining pressures ranging from 200 to 6000 psi. The flow experiments were performed using a state-of-the-art miniature core-flooding apparatus integrated with a high-resolution, X-ray microtomography system. We visualized fluid occupancies, proppant embedment, and shale deformation under different flow and stress conditions. We examined deformation of pore space within the proppant packs and its impact on permeability and residual trapping, proppant embedment due to changes in net confining stress, shale surface deformation, and disintegration of proppant grains at high stress conditions. In particular, geometrical deformation and two-phase flow effects within the proppant pack impacting hydraulic conductivity of the medium were probed. A significant reduction in effective oil permeability at irreducible water saturation was observed due to increase in confining pressure. We propose different mechanisms responsible for the observed permeability reduction in different fracture packings. Samples with dissimilar proppant grain distributions showed significantly different proppant embedment behavior. Thinner proppant layer increased embedment significantly and lowered the onset confining pressure of embedment. As confining stress was increased, small embedments caused the surface of the shale to fracture. The produced shale fragments were

  7. Chemical and physical changes during seawater flow through intact dunite cores: An experimental study at 150-200 °C

    Science.gov (United States)

    Luhmann, Andrew J.; Tutolo, Benjamin M.; Bagley, Brian C.; Mildner, David F. R.; Scheuermann, Peter P.; Feinberg, Joshua M.; Ignatyev, Konstantin; Seyfried, William E.

    2017-10-01

    Two flow-through experiments were conducted to assess serpentinization of intact dunite cores. Permeability and fluid chemistry indicate significantly more reaction during the second experiment at 200 °C than the first experiment at 150 °C. Permeability decreased by a factor of 2.4 and 25 during the experiments at 150 and 200 °C, respectively. Furthermore, hydrogen and methane concentrations exceeded 600 μmol/kg and 300 μmol/kg during the 200 °C experiment, and were one and two orders of magnitude higher, respectively, than the 150 °C experiment. Fe K-edge X-ray absorption near edge structure analyses of alteration minerals demonstrated Fe oxidation that occurred during the 200 °C experiment. Vibrating sample magnetometer measurements on post-experimental cores indicated little to no magnetite production, suggesting that the hydrogen was largely generated by the oxidation of iron as olivine was converted to ferric iron (Fe(III)) serpentine and/or saponite. Scanning electron microscopy images suggested secondary mineralization on the post-experimental core from the 200 °C experiment, portraying the formation of a secondary phase with a honeycomb-like texture as well as calcite and wollastonite. Scanning electron microscopy images also illustrated dissolution along linear bands through the interiors of olivine crystals, possibly along pathways with abundant fluid inclusions. Energy dispersive X-ray spectroscopy identified Cl uptake in serpentine, while Fourier transform-infrared spectroscopy suggested the formation of serpentine, saponite, and talc. However, no change was observed when comparing pre- and post-experimental X-ray computed tomography scans of the cores. Furthermore, (ultra) small angle neutron scattering datasets were collected to assess changes in porosity, surface area, and fractal characteristics of the samples over the ≈ 1 nm- to 10 μm-scale range. The results from the 200 °C post-experimental core generally fell within the range of

  8. Decreased arterial PO2, not O2 content, increases blood flow through intrapulmonary arteriovenous anastomoses at rest.

    Science.gov (United States)

    Duke, Joseph W; Davis, James T; Ryan, Benjamin J; Elliott, Jonathan E; Beasley, Kara M; Hawn, Jerold A; Byrnes, William C; Lovering, Andrew T

    2016-09-01

    The mechanism(s) that regulate hypoxia-induced blood flow through intrapulmonary arteriovenous anastomoses (QIPAVA ) are currently unknown. Our previous work has demonstrated that the mechanism of hypoxia-induced QIPAVA is not simply increased cardiac output, pulmonary artery systolic pressure or sympathetic nervous system activity and, instead, it may be a result of hypoxaemia directly. To determine whether it is reduced arterial PO2 (PaO2) or O2 content (CaO2) that causes hypoxia-induced QIPAVA , individuals were instructed to breathe room air and three levels of hypoxic gas at rest before (control) and after CaO2 was reduced by 10% by lowering the haemoglobin concentration (isovolaemic haemodilution; Low [Hb]). QIPAVA , assessed by transthoracic saline contrast echocardiography, significantly increased as PaO2 decreased and, despite reduced CaO2 (via isovolaemic haemodilution), was similar at iso-PaO2. These data suggest that, with alveolar hypoxia, low PaO2 causes the hypoxia-induced increase in QIPAVA , although where and how this is detected remains unknown. Alveolar hypoxia causes increased blood flow through intrapulmonary arteriovenous anastomoses (QIPAVA ) in healthy humans at rest. However, it is unknown whether the stimulus regulating hypoxia-induced QIPAVA is decreased arterial PO2 (PaO2) or O2 content (CaO2). CaO2 is known to regulate blood flow in the systemic circulation and it is suggested that IPAVA may be regulated similar to the systemic vasculature. Thus, we hypothesized that reduced CaO2 would be the stimulus for hypoxia-induced QIPAVA . Blood volume (BV) was measured using the optimized carbon monoxide rebreathing method in 10 individuals. Less than 5 days later, subjects breathed room air, as well as 18%, 14% and 12.5% O2 , for 30 min each, in a randomized order, before (CON) and after isovolaemic haemodilution (10% of BV withdrawn and replaced with an equal volume of 5% human serum albumin-saline mixture) to reduce [Hb] (Low [Hb]). PaO2

  9. Survival and growth of newly transformed Lampsilis cardium and Lampsilis siliquoidea in a flow-through, continuous feeding test system

    Science.gov (United States)

    Meinertz, Jeffery R.; Schreier, Theresa M.; Hess, Karina R.; Bartsch, Michelle

    2011-01-01

    A test system was evaluated for assessing chronic toxicity of waterborne chemicals with early life stage mussels. To determine if the test system could result in ≥80% survival in a control (unexposed) group, fat mucket mussels (Lampsilis siliquoidea Barnes, 1823) and plain pocketbook mussels (L. cardium Rafinesque, 1820) 1 day post transformation were stocked into test chambers (250 mL beakers, water volume, 200 mL, 21 °C, 40 mussels of 1 species per chamber) within a test system constructed for conducting chronic, continuous exposure, flow-through toxicity tests. The test system contained 60 chambers containing silica sand, 30 chambers with L. siliquoidea, and 30 with L. cardium. Each chamber in the continuous feeding system received 1 of 6 food types prepared with concentrated algal products. After 28 days, mussels were harvested from chambers to assess survival and growth. For L. siliquoidea, mean survival ranged from 34 to 80% and mean shell length ranged from 464 to 643 µm. For L. cardium, mean survival ranged from 12 to 66% and mean shell length ranged from 437 to 612 µm. The maximum mean growth rate for L. siliquoidea was 12.7 µm/d and for L. cardium was 11.8 µm/d. When offered a continuous diet of Nannochloropsis, Tetraselmis, and Chlorella for 28 days in the test system, the survival of 1 day post transformation L. siliquoidea was 80%. The test system can be easily enhanced with a pumping system continuously delivering test chemical to the test system's flow stream allowing for chronic toxicity tests with 1 day post transformation mussels.

  10. A model for complex flows of soft glassy materials with application to flows through fixed fiber beds

    International Nuclear Information System (INIS)

    Sarkar, Arijit; Koch, Donald L.

    2015-01-01

    The soft glassy rheology (SGR) model has successfully described the time dependent simple shear rheology of a broad class of complex fluids including foams, concentrated emulsions, colloidal glasses, and solvent-free nanoparticle-organic hybrid materials (NOHMs). The model considers a distribution of mesoscopic fluid elements that hop from trap to trap at a rate which is enhanced by the work done to strain the fluid element. While an SGR fluid has a broad exponential distribution of trap energies, the rheology of NOHMs is better described by a narrower energy distribution and we consider both types of trap energy distributions in this study. We introduce a tensorial version of these models with a hopping rate that depends on the orientation of the element relative to the mean stress field, allowing a range of relative strengths of the extensional and simple shear responses of the fluid. As an application of these models we consider the flow of a soft glassy material through a dilute fixed bed of fibers. The dilute fixed bed exhibits a range of local linear flows which alternate in a chaotic manner with time in a Lagrangian reference frame. It is amenable to an analytical treatment and has been used to characterize the strong flow response of many complex fluids including fiber suspensions, dilute polymer solutions and emulsions. We show that the accumulated strain in the fluid elements has an abrupt nonlinear growth at a Deborah number of order one in a manner similar to that observed for polymer solutions. The exponential dependence of the hopping rate on strain leads to a fluid element deformation that grows logarithmically with Deborah number at high Deborah numbers. SGR fluids having a broad range of trap energies flowing through fixed beds can exhibit a range of rheological behaviors at small Deborah numbers ranging from a yield stress, to a power law response and finally to Newtonian behavior

  11. Role of submerged vegetation in the retention processes of three plant protection products in flow-through stream mesocosms.

    Science.gov (United States)

    Stang, Christoph; Wieczorek, Matthias Valentin; Noss, Christian; Lorke, Andreas; Scherr, Frank; Goerlitz, Gerhard; Schulz, Ralf

    2014-07-01

    Quantitative information on the processes leading to the retention of plant protection products (PPPs) in surface waters is not available, particularly for flow-through systems. The influence of aquatic vegetation on the hydraulic- and sorption-mediated mitigation processes of three PPPs (triflumuron, pencycuron, and penflufen; logKOW 3.3-4.9) in 45-m slow-flowing stream mesocosms was investigated. Peak reductions were 35-38% in an unvegetated stream mesocosm, 60-62% in a sparsely vegetated stream mesocosm (13% coverage with Elodea nuttallii), and in a similar range of 57-69% in a densely vegetated stream mesocosm (100% coverage). Between 89% and 93% of the measured total peak reductions in the sparsely vegetated stream can be explained by an increase of vegetation-induced dispersion (estimated with the one-dimensional solute transport model OTIS), while 7-11% of the peak reduction can be attributed to sorption processes. However, dispersion contributed only 59-71% of the peak reductions in the densely vegetated stream mesocosm, where 29% to 41% of the total peak reductions can be attributed to sorption processes. In the densely vegetated stream, 8-27% of the applied PPPs, depending on the logKOW values of the compounds, were temporarily retained by macrophytes. Increasing PPP recoveries in the aqueous phase were accompanied by a decrease of PPP concentrations in macrophytes indicating kinetic desorption over time. This is the first study to provide quantitative data on how the interaction of dispersion and sorption, driven by aquatic macrophytes, influences the mitigation of PPP concentrations in flowing vegetated stream systems. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. The effects of vasoactive agents on flow through saphenous vein grafts during lower-extremity peripheral vascular surgery.

    Science.gov (United States)

    Maslow, Andrew D; Bert, Arthur; Slaiby, Jeffrey; Carney, William; Marcaccio, Edward

    2007-06-01

    The purpose of this study was to assess the effects of hemodynamic alterations on vein graft flow during peripheral vascular surgery. It was hypothesized that vasopressors can be administered without compromising flow through the vein grafts. Tertiary care center, university medical center. Randomized placebo-controlled double-blinded study. The effects of phenylephrine, epinephrine, milrinone, intravenous fluid, and placebo on newly constructed peripheral vein grafts were assessed in 60 patients (12 patients in each of 5 groups). Systemic and central hemodynamics were measured by using intra-arterial and pulmonary artery catheters. Vein graft flow was measured by using a transultrasonic flow probe (Transultrasonic Inc, Ithaca, NY). Phenylephrine increased systemic mean blood pressure (mBP) (68.2-94.0 mmHg, p < 0.01), systemic vascular resistance (SVR) (1,091-1,696 dynes x sec x cm(-5), p < 0.001), and vein graft flow (39.5-58.9 mL/min, p < 0.01), whereas cardiac output remained unchanged. Epinephrine resulted in increased cardiac output (4.4-6.9 L/min, p < 0.01) and mBP (72.7-89.1 mmHg, p < 0.01), whereas vein graft flow was reduced in 6 of 12 patients. Intravenous fluid administration resulted in a relatively smaller increase in graft flow (37.6-46.0 mL/min, p < 0.05), an increase in cardiac output, and an insignificant decrease in SVR. Other treatments had either little or no effect on vein graft flow. The study hypothesis was partly supported. Although both phenylephrine and epinephrine increased blood pressure, only the former increased vein graft flow in all patients. In conjunction with increases in graft flow after fluid administration, these data suggest that factors affecting vein graft flow are not just simply related to systemic hemodynamics.

  13. A model for complex flows of soft glassy materials with application to flows through fixed fiber beds

    KAUST Repository

    Sarkar, Arijit

    2015-11-01

    © 2015 The Society of Rheology. The soft glassy rheology (SGR) model has successfully described the time dependent simple shear rheology of a broad class of complex fluids including foams, concentrated emulsions, colloidal glasses, and solvent-free nanoparticle-organic hybrid materials (NOHMs). The model considers a distribution of mesoscopic fluid elements that hop from trap to trap at a rate which is enhanced by the work done to strain the fluid element. While an SGR fluid has a broad exponential distribution of trap energies, the rheology of NOHMs is better described by a narrower energy distribution and we consider both types of trap energy distributions in this study. We introduce a tensorial version of these models with a hopping rate that depends on the orientation of the element relative to the mean stress field, allowing a range of relative strengths of the extensional and simple shear responses of the fluid. As an application of these models we consider the flow of a soft glassy material through a dilute fixed bed of fibers. The dilute fixed bed exhibits a range of local linear flows which alternate in a chaotic manner with time in a Lagrangian reference frame. It is amenable to an analytical treatment and has been used to characterize the strong flow response of many complex fluids including fiber suspensions, dilute polymer solutions and emulsions. We show that the accumulated strain in the fluid elements has an abrupt nonlinear growth at a Deborah number of order one in a manner similar to that observed for polymer solutions. The exponential dependence of the hopping rate on strain leads to a fluid element deformation that grows logarithmically with Deborah number at high Deborah numbers. SGR fluids having a broad range of trap energies flowing through fixed beds can exhibit a range of rheological behaviors at small Deborah numbers ranging from a yield stress, to a power law response and finally to Newtonian behavior.

  14. Comparative study of the discrete velocity and lattice Boltzmann methods for rarefied gas flows through irregular channels.

    Science.gov (United States)

    Su, Wei; Lindsay, Scott; Liu, Haihu; Wu, Lei

    2017-08-01

    Rooted from the gas kinetics, the lattice Boltzmann method (LBM) is a powerful tool in modeling hydrodynamics. In the past decade, it has been extended to simulate rarefied gas flows beyond the Navier-Stokes level, either by using the high-order Gauss-Hermite quadrature, or by introducing the relaxation time that is a function of the gas-wall distance. While the former method, with a limited number of discrete velocities (e.g., D2Q36), is accurate up to the early transition flow regime, the latter method (especially the multiple relaxation time (MRT) LBM), with the same discrete velocities as those used in simulating hydrodynamics (i.e., D2Q9), is accurate up to the free-molecular flow regime in the planar Poiseuille flow. This is quite astonishing in the sense that less discrete velocities are more accurate. In this paper, by solving the Bhatnagar-Gross-Krook kinetic equation accurately via the discrete velocity method, we find that the high-order Gauss-Hermite quadrature cannot describe the large variation in the velocity distribution function when the rarefaction effect is strong, but the MRT-LBM can capture the flow velocity well because it is equivalent to solving the Navier-Stokes equations with an effective shear viscosity. Since the MRT-LBM has only been validated in simple channel flows, and for complex geometries it is difficult to find the effective viscosity, it is necessary to assess its performance for the simulation of rarefied gas flows. Our numerical simulations based on the accurate discrete velocity method suggest that the accuracy of the MRT-LBM is reduced significantly in the simulation of rarefied gas flows through the rough surface and porous media. Our simulation results could serve as benchmarking cases for future development of the LBM for modeling and simulation of rarefied gas flows in complex geometries.

  15. Assessing honeybee and wasp thermoregulation and energetics-New insights by combination of flow-through respirometry with infrared thermography

    Energy Technology Data Exchange (ETDEWEB)

    Stabentheiner, Anton, E-mail: anton.stabentheiner@uni-graz.at [Institut fuer Zoologie, Karl-Franzens-Universitaet Graz, Universitaetsplatz 2, A-8010 Graz (Austria); Kovac, Helmut, E-mail: he.kovac@uni-graz.at [Institut fuer Zoologie, Karl-Franzens-Universitaet Graz, Universitaetsplatz 2, A-8010 Graz (Austria); Hetz, Stefan K. [Department of Animal Physiology/Systems Neurobiology and Neural Computation, Philippstrasse 13-Leonor Michaelis Haus, Humboldt-Universitaet zu Berlin, 10115 Berlin (Germany); Kaefer, Helmut; Stabentheiner, Gabriel [Institut fuer Zoologie, Karl-Franzens-Universitaet Graz, Universitaetsplatz 2, A-8010 Graz (Austria)

    2012-04-20

    Highlights: Black-Right-Pointing-Pointer We demonstrate the benefits of a combined use of infrared thermography with respiratory measurements in insect ecophysiological research. Black-Right-Pointing-Pointer Infrared thermography enables repeated investigation of behaviour and thermoregulation without behavioural impairment. Black-Right-Pointing-Pointer Comparison with respirometry brings new insights into the mechanisms of energetic optimisation of bee and wasp foraging. Black-Right-Pointing-Pointer Combination of methods improves interpretation of respiratory traces in determinations of insect critical thermal limits. - Abstract: Endothermic insects like honeybees and some wasps have to cope with an enormous heat loss during foraging because of their small body size in comparison to endotherms like mammals and birds. The enormous costs of thermoregulation call for optimisation. Honeybees and wasps differ in their critical thermal maximum, which enables the bees to kill the wasps by heat. We here demonstrate the benefits of a combined use of body temperature measurement with infrared thermography, and respiratory measurements of energy turnover (O{sub 2} consumption or CO{sub 2} production via flow-through respirometry) to answer questions of insect ecophysiological research, and we describe calibrations to receive accurate results. To assess the question of what foraging honeybees optimise, their body temperature was compared with their energy turnover. Honeybees foraging from an artificial flower with unlimited sucrose flow increased body surface temperature and energy turnover with profitability of foraging (sucrose content of the food; 0.5 or 1.5 mol/L). Costs of thermoregulation, however, were rather independent of ambient temperature (13-30 Degree-Sign C). External heat gain by solar radiation was used to increase body temperature. This optimised foraging energetics by increasing suction speed. In determinations of insect respiratory critical thermal limits

  16. Stochastic Models of Macroscale Quantities for the Prediction of the REV Scale for Multiphase Flow through Porous Media

    Science.gov (United States)

    Talbot, C.; McClure, J. E.; Armstrong, R. T.; Mostaghimi, P.; Hu, Y.; Miller, C. T.

    2017-12-01

    Microscale experimental and computational methods can be used to evaluate fundamental microscale mechanisms and deduce macroscale constitutive relationships and parameter values. The link between the microscale and the macroscale is especially demanding, because technical issues arise regarding the necessary scale of the system needed for a meaningful set of macroscale measures to be insensitive to the size of the system, which is known as a representative elementary volume (REV). While the REV scale is routinely determined for single-phase flow in porous media, no systematic study of the scale of a REV for the comprehensive set of macroscale measures considered here has been reported in the literature. A comprehensive set of measures of the macroscale state is developed. We further develop and apply methods to predict the REV scale and quantify the uncertainty of the estimate for this set of macroscale quantities. We model the system state in terms of standard errors of macroscale quantities as a multivariate Gaussian process dependent on the size of the domain simulated. We determine predictive distributions of function values and a posterior distributions of weights using standard kernels, as well as a kernel constructed using relationships between physical quantities. For each kernel, we discuss the decay of the mean and covariance with increasing domain size, and use cross-validation to facilitate model selection. The procedure yields a model of the domain size needed to achieve a REV with quantifiable uncertainty. We present results in the context of multiphase fluid flow through a highly resolved realization of sandstone imaged using micro-CT. A 1440x1440x4320 section of the full 2520x2520x5280 imaged medium is simulated using the lattice-Boltzmann method. We compare the fidelity of the predictive model with results obtained by an analogous approach using polynomial regression.

  17. Modeling flow through the sand pack: implications for groundwater sampling from multi- level monitoring wells in fractured bedrock aquifers.

    Science.gov (United States)

    Kozuskanich, J.; Novakowski, K.; Anderson, B.

    2009-05-01

    Multi-level piezometers are often used in groundwater studies to monitor multiple zones within a single borehole. In the fractured rock setting the monitoring intervals are typically designed to isolate discrete fracture features (single fractures or fracture zones). This can be very useful for determining vertical connectivity and the distribution of a contaminant within a fractured rock aquifer. A simple and inexpensive method for completing a bedrock borehole as a multi-level piezometer is to use PVC screen and riser, a sand pack around the screened section, and bentonite to isolate each interval. Flow into the borehole is dominantly confined to the intersecting discrete fracture features. The objective of this study is to examine the nature of the flow through the sand pack and screen slots as water travels from the fracture to the pump intake under pumping conditions. Our conceptual model suggests only a portion of the sand pack in the vicinity of the fractures should be hydraulically active in this scenario. Thus, portions of the wellbore may remain stagnant during pumping depending on the location of the pump intake with respect to the fractures. Flow paths in the sand pack may be controlled by the relationship between the transmissivity of the fracture and screen slots. HydroGeoSphere, a numerical model for flow and solute transport in discrete fractures and porous media, will be used to validate the conceptual model and define the head and velocity profiles in a multi-level interval under various pumping rate and discrete fracture aperture scenarios. The results of this study could have implications for defining a "well volume" in sampling protocols designed for multi-level piezometers in bedrock aquifer systems. The results may also be a useful tool for interpreting the significance of the sand pack as a source of bacteria in water quality monitoring studies that use multi-level piezometer construction of this sort.

  18. Origin and hydrogeochemistry of a shallow flow-through lake on a Pleistocene piedmont, northern Spanish Meseta

    Directory of Open Access Journals (Sweden)

    Margarita Jambrina

    2013-06-01

    Full Text Available The Cristo lagoon, situated on Neogene deposits in the northern Spanish Meseta, occupies a shallow depression on a Pleistocene piedmont. The development of the lacustrine depression on the piedmont was favoured by the fault network, reinforced by substrateloss by weathering, probably during the late Quaternary. Even during the hot summer season, salinity is low, with concentrations of total dissolved solids (TDS being around 150 mg L–1. Only when the lagoon is almost dry do TDS concentrations exceed 500 mg L–1, sometimes rising as high as 1700 mg L–1. Whenthe lake level is high, lake chemistry is dominated by Na+, Ca2+, HCO3– and Cl–. During drier stages, there is a relative increase in Ca2+, Mg2+, Cl–, and SO42–, trending toward a calcium chloride-sulphate brine. Values of pH are above 9 during late spring and summer, resulting primarily from evaporative degassing favoured by the shallow depth of water, and secondarily from photosynthesis by the abundant submerged macrophytes. The infilling deposits, less than 0.5 m thick, are dark brown, massive, sandy muds consisting of quartz and clays (illite, kaolinite, smectite, all of which are allogenic in origin. The main source of dissolved sulphate was the oxidation of sulphides during weathering of lower Palaeozoic rocks in the catchment area. The 13C-depleted nature of dissolved inorganic carbon indicates an origin mostly by respiration and oxidation of organic matter. Geomorphology and hydrogeochemistry indicate a flow-through lake dominated essentially by groundwater flows. 

  19. WHATS-3: An Improved Flow-Through Multi-bottle Fluid Sampler for Deep-Sea Geofluid Research

    Directory of Open Access Journals (Sweden)

    Junichi Miyazaki

    2017-06-01

    Full Text Available Deep-sea geofluid systems, such as hydrothermal vents and cold seeps, are key to understanding subseafloor environments of Earth. Fluid chemistry, especially, provides crucial information toward elucidating the physical, chemical, and biological processes that occur in these ecosystems. To accurately assess fluid and gas properties of deep-sea geofluids, well-designed pressure-tight fluid samplers are indispensable and as such they are important assets of deep-sea geofluid research. Here, the development of a new flow-through, pressure-tight fluid sampler capable of four independent sampling events (two subsamples for liquid and gas analyses from each is reported. This new sampler, named WHATS-3, is a new addition to the WHATS-series samplers and a major upgrade from the previous WHATS-2 sampler with improvements in sample number, valve operational time, physical robustness, and ease of maintenance. Routine laboratory-based pressure tests proved that it is suitable for operation up to 35 MPa pressure. Successful field tests of the new sampler were also carried out in five hydrothermal fields, two in Indian Ocean, and three in Okinawa Trough (max. depth 3,300 m. Relations of Mg and major ion species demonstrated bimodal mixing trends between a hydrothermal fluid and seawater, confirming the high quality of fluids sampled. The newly developed WHATS-3 sampler is well-balanced in sampling capability, field usability, and maintenance feasibility, and can serve as one of the best geofluid samplers available at present to conduct efficient research of deep-sea geofluid systems.

  20. Structural characterisation of pretreated solids from flow-through liquid hot water treatment of sugarcane bagasse in a fixed-bed reactor

    CSIR Research Space (South Africa)

    Reddy, P

    2015-05-01

    Full Text Available Untreated sugarcane bagasse and sugarcane bagasse pretreated with flow-through liquid hot water (LHW) treatment (170-207°C and 204-250 ml/min) in a fixed-bed reactor have been structurally characterised. Field emission gun scanning electron...

  1. Effect of stocking density and source of animal protein on growth and survival of rainbow trout fingerlings in flow-through system at Nuwakot, Nepal

    Directory of Open Access Journals (Sweden)

    Prem Timalsina

    2017-11-01

    Full Text Available An experiment was conducted in outdoor nursing raceways with flow-through system (2.7 m2 at the Fisheries Research Station, Trishuli, Nuwakot Nepal for 249 days to evaluate the effect of stocking density and sources of animal protein on growth and survival of rainbow trout fingerlings production. The experiment was conducted in 2 × 2 factorial completely randomized design having two stocking densities, (density-1: 10 kg/m2 and density-2: 12.5 kg/m2 and two diets (diet-1: shrimp meal based diet and diet-2: 5% bovine blood meal mixed diet. All treatments were replicated thrice. Water from the Trishuli river was used and 50 cm water depth was maintained in all treatments. Initial feeding rate of 10% of the body weight was gradually reduced to 8, 7, 6, 5, 4 and 3% was maintained for the subsequent months. Feeding was done 5 times a day throughout the study period. Results showed that the mean total harvest weight in diet-1 (30.17 ± 1.34 kg was significantly higher than in diet-2 (22.77 ± 1.34 kg; however, no significance difference was observed at stocking density levels. Mean survival of fish in diet-1 (60.30 ± 2.08% was significantly higher than diet-2 (47.78 ± 2.08%. Similarly, survivability of fish in density-1 (63.45 ± 2.08% was significantly higher than in density-2 (44.63 ± 2.08%. The mean dissolve oxygen at density-2 (8.89 ± 0.02 mg/L was significantly lower to that of density-1 (8.94 ± 0.02 mg/L and B:C ratio was high with shrimp meal based diet and high stocking density (T3. In the present study, the treatment with shrimp meal based diet and high stocking density (T3 was superior with high mean total harvest weight, gross fish yield, low FCR and high B: C ratio than other treatment combinations. The present study demonstrated that growth, production and survival performances of rainbow trout in the present experimental condition were not satisfactory by substituting a part of shrimp meal by blood meal.

  2. Cross-equatorial flow through an abyssal channel under the complete Coriolis force: Two-dimensional solutions

    Science.gov (United States)

    Stewart, A. L.; Dellar, P. J.

    The component of the Coriolis force due to the locally horizontal component of the Earth's rotation vector is commonly neglected, under the so-called traditional approximation. We investigate the role of this "non-traditional" component of the Coriolis force in cross-equatorial flow of abyssal ocean currents. We focus on the Antarctic Bottom Water (AABW), which crosses from the southern to the northern hemisphere through the Ceara abyssal plain in the western Atlantic ocean. The bathymetry in this region resembles a northwestward channel, connecting the Brazil Basin in the south to the Guyana Basin in the north. South of the equator, the AABW leans against the western continental rise, consistent with a northward flow in approximate geostrophic balance. The AABW then crosses to the other side of the abyssal channel as it crosses the equator, and flows into the northern hemisphere leaning towards the east against the Mid-Atlantic Ridge. The non-traditional component of the Coriolis force is strongest close to the equator. The traditional component vanishes at the equator, being proportional to the locally vertical component of the Earth's rotation vector. The weak stratification of the abyssal ocean, and subsequent small internal deformation radius, defines a relatively short characteristic horizontal lengthscale that tends to make non-traditional effects more prominent. Additionally, the steep gradients of the channel bathymetry induce large vertical velocities, which are linked to zonal accelerations by the non-traditional components of the Coriolis force. We therefore expect non-traditional effects to play a substantial role in cross-equatorial transport of the AABW. We present asymptotic steady solutions for non-traditional shallow water flow through an idealised abyssal channel, oriented at an oblique angle to the equator. The current enters from the south, leaning up against the western side of the channel in approximate geostrophic balance, and crosses the

  3. TRIO experiment

    Energy Technology Data Exchange (ETDEWEB)

    Clemmer, R.G.; Finn, P.A.; Malecha, R.F.; Misra, B.; Billone, M.C.; Bowers, D.L.; Fischer, A.K.; Greenwood, L.R.; Mattas, R.F.; Tam, S.W.

    1984-09-01

    The TRIO experiment is a test of in-situ tritium recovery and heat transfer performance of a miniaturized solid breeder blanket assembly. The assembly (capsule) was monitored for temperature and neutron flux profiles during irradiation and a sweep gas flowed through the capsule to an anaytical train wherein the amounts of tritium in its various chemical forms were determined. The capsule was designed to operate at different temperatures and sweep gas conditions. At the end of the experiment the amount of tritium retained in the solid was at a concentration of less than 0.1 wppM. More than 99.9% of tritium generated during the experiment was successfully recovered. The results of the experiment showed that the tritium inventories at the beginning and at the end of the experiment follow a relationship which appears to be characteristic of intragranular diffusion.

  4. Impact of tylosin phosphate and distillers dried grains with solubles on energy and nutrient digestibility and flow through the gastrointestinal tract in growing pigs.

    Science.gov (United States)

    Pilcher, C M; Arentson, R; Patience, J F

    2013-12-01

    The objective of this study was to evaluate the impact of tylosin phosphate (TP) on energy and nutrient digestibility and flow through the gastrointestinal tract in growing pigs fed corn-soybean meal or corn-soybean meal-distillers dried grains with solubles (DDGS) based diets. Eighteen barrows (initial BW = 32.6 ± 1.2 kg) were surgically fitted with a T-cannula in the distal ileum and allotted to a Youden square design with 6 diets and 3 replicate periods. Treatments were arranged in a 2 × 2 factorial: TP (0 vs. 44 mg/kg) and DDGS (0 vs. 25%). Two N-free dietary treatments (0 vs. 44 mg/kg TP) were also included for determining basal ileal endogenous AA losses (IAAend) and the effect of TP on basal IAAend. Replicate periods included 4 d of adaptation to treatments and 2 sampling periods. Fecal collection occurred on d 5 and 6 and ileal digesta collection occurred on d 7 and 8 for sampling period 1 whereas sampling period 2 included fecal collection on d 11 and 12 and ileal digesta collection on d 13 and 14. Apparent ileal digestibility (AID) and apparent total tract digestibility (ATTD) were calculated for DM, energy, and NDF. The AID and standardized ileal digestibility (SID) of AA were calculated. Inclusion of DDGS reduced AID (68.0 vs. 72.8%; P < 0.001) and ATTD (79.9 vs. 85.0%; P < 0.001) of energy. There were no effects of TP on energy digestibility. The DDGS inclusion increased the amount of GE (1.47 vs. 1.18 Mcal/kg DMI; P < 0.001) and NDF (94 vs. 60 g/kg DMI; P < 0.001) remaining at the terminal ileum; however, hindgut disappearance of energy (0.55 vs. 0.53 Mcal/kg DMI) and NDF (13 vs. 15 g/kg DMI) was similar between the corn-soybean meal-DDGS and corn-soybean meal based diets. There were no effects of TP on basal IAAend; therefore, SID AA values were calculated using means of the 2 N-free diets. The SID of Lys (79.6 vs. 84.1%; P < 0.001) and all other indispensible AA, except Leu, was lower in the DDGS diets. Inclusion of TP did not influence SID of AA

  5. A mathematical model of a steady flow through the Kaplan turbine - The existence of a weak solution in the case of an arbitrarily large inflow

    Science.gov (United States)

    Neustupa, Tomáš

    2017-07-01

    The paper presents the mathematical model of a steady 2-dimensional viscous incompressible flow through a radial blade machine. The corresponding boundary value problem is studied in the rotating frame. We provide the classical and weak formulation of the problem. Using a special form of the so called "artificial" or "natural" boundary condition on the outflow, we prove the existence of a weak solution for an arbitrarily large inflow.

  6. Evaluation of the CO2 sequestration capacity for coal fly ash using a flow-through column reactor under ambient conditions

    International Nuclear Information System (INIS)

    Jo, Ho Young; Ahn, Joon-Hoon; Jo, Hwanju

    2012-01-01

    Highlights: ► A conceptual in-situ mineral carbonation method using a coal ash pond is proposed. ► CO 2 uptake occurred by carbonation reaction of CO 2 with Ca 2+ ions from coal fly ash. ► The CO 2 sequestration capacity was affected by the solid dosage. ► Seawater can be used as a solvent for mineral carbonation of coal fly ash. - Abstract: An in-situ CO 2 sequestration method using coal ash ponds located in coastal regions is proposed. The CO 2 sequestration capacity of coal fly ash (CFA) by mineral carbonation was evaluated in a flow-through column reactor under various conditions (solid dosage: 100–330 g/L, CO 2 flow rate: 20–80 mL/min, solvent type: deionized (DI) water, 1 M NH 4 Cl solution, and seawater). The CO 2 sequestration tests were conducted on CFA slurries using flow-through column reactors to simulate more realistic flow-through conditions. The CO 2 sequestration capacity increased when the solid dosage was increased, whereas it was affected insignificantly by the CO 2 flow rate. A 1 M NH 4 Cl solution was the most effective solvent, but it was not significantly different from DI water or seawater. The CO 2 sequestration capacity of CFA under the flow-through conditions was approximately 0.019 g CO 2 /g CFA under the test conditions (solid dosage: 333 g/L, CO 2 flow rate: 40 mL/min, and solvent: seawater).

  7. Flow-through PCR on a 3D qiandu-shaped polydimethylsiloxane (PDMS) microdevice employing a single heater: toward microscale multiplex PCR.

    Science.gov (United States)

    Wu, Wenming; Loan, Kieu The Loan; Lee, Nae Yoon

    2012-05-07

    Consistent temperature control in an on-chip flow-through polymerase chain reaction (PCR) employing two or more heaters is one of the main obstacles for device miniaturization and integration when realizing micro total analysis systems (μTAS), and also leads to operational complexity. In this study, we propose a qiandu (right triangular prism)-shaped polydimethylsiloxane (PDMS) microdevice with serpentine microchannels fabricated on its slanted plane, and apply the device for an on-chip flow-through PCR employing a single heater. The inclined nature of the qiandu-shaped microdevice enables the formation of a surface temperature gradient along the slanted plane of the microdevice in a height-dependent manner by the use of a single heater, and enables liquid to traverse over wide ranges of temperatures, including the three temperature zones--denaturation, annealing, and extension temperatures--required in a typical PCR. The feasibility of the qiandu-shaped PDMS microdevice as a versatile platform for performing a flow-through PCR was examined by employing multiple templates and varying the inclination angle of the device. In addition, the potential of performing a multiplex PCR using a single qiandu-shaped PDMS microdevice was explored. A 409 bp long gene fragment effective as a marker for diagnosing lung cancer and a 230 bp long gene fragment from a plasmid vector were simultaneously amplified in less than 25 min on a single microdevice, paving the way for a microscale, multiplex PCR on a single device employing a single heater.

  8. "Mini-Flow-Through" Deep Inferior Epigastric Perforator Flap for Breast Reconstruction with Preservation of Both Internal Mammary and Deep Inferior Epigastric Vessels

    Directory of Open Access Journals (Sweden)

    Toshihiko Satake

    2015-11-01

    Full Text Available This procedure was developed for preservation of the rectus muscle components and deep inferior epigastric vessel after deep inferior epigastric perforator (DIEP flap harvesting. A 53-year-old woman with granuloma caused by silicone injection underwent bilateral nipple-sparing mastectomies and immediate reconstruction with "mini-flow-through" DIEP flaps. The flaps were dissected based on the single largest perforator with a short segment of the lateral branch of the deep inferior epigastric vessel that was transected as a free flap for breast reconstruction. The short segments of the donor deep inferior epigastric vessel branch are primarily end-to-end anastomosed to each other. A short T-shaped pedicle mini-flow-through DIEP flap is interposed in the incised recipient's internal mammary vessels with two arterial and four concomitant venous anastomoses. Although it requires multiple vascular anastomoses and a short pedicle for the flap setting, the mini-flow-through DIEP flap provides a large pedicle caliber, enabling safer microsurgical anastomosis and well-vascularized tissue for creating a natural breast without consuming time or compromising the rectus muscle components and vascular flow of both the deep inferior epigastric and internal mammary vessels.

  9. Design, Preparation and Performance Study of On-Chip Flow-Through Amperometric Sensors with an Integrated Ag/AgCl Reference Electrode

    Directory of Open Access Journals (Sweden)

    He Zhang

    2018-03-01

    Full Text Available To improve the reference potential stability of on-chip amperometric sensors, we propose a novel integrated Ag/AgCl reference electrode structure. This structure can refresh the saturated potassium chloride filling solution surrounding the Ag/AgCl electrode. We then designed a flow-through amperometric sensor and a multilayer microfluidic chip based on the integrated reference electrode. In order to improve the detection signal strength of the flow-through sensor, a numerical simulation model was established. The simulation results showed that a combination of (1 using a step-type detection cell structure that maintains micro-channel width while reducing micro-channel height, and (2 controlling the sample flow rate to limit the mass transfer of the sensor surface effectively, improves the detection signal strength. The step-type detection cell structure had dimensions of 200 μm × 200 μm × 100 μm (length × width × height, and the electroosmotic flow driving voltage was 120 V/cm. Finally, successful trace detection of Mg2+ and Pb2+ in the water was achieved using the amperometric sensor and microfluidic chip: detection limits were 5 μmol/L and 84 μmol/L. The preparation of an on-chip flow-through amperometric sensor with an integrated Ag/AgCl reference electrode will facilitate improved portability of microfluidic detection technology.

  10. [Effects of flow-through descending branch of lateral circumflex femoral artery flap on repairing high-voltage electrical burn wounds of wrist of patients].

    Science.gov (United States)

    Shen, Y M; Chen, X; Zhang, C; Wang, C; Qin, F J; Ma, C X; Hu, X H

    2017-07-20

    Objective: To investigate the effects of flow-through descending branch of lateral circumflex femoral artery flap on repairing high-voltage electrical burn wounds of wrist of patients. Methods: From January 2014 to June 2016, 5 patients with high-voltage electrical burn of unilateral wrist were hospitalized in our burn ward, with extensive necrosis of skin soft tissue of burn wrist. Five patients were transferred to our burn ward 6 to 12 days post injury after undergoing emergency dermotomy of wrist to reduce tension in other hospitals. In 2 to 3 days after admission, operation was performed by two surgeon group at the same time, when patients' general condition were stable. One group underwent debridement and the other group designed and dissected flap according to the range of skin soft tissue defect of wrist. Wrist wounds after debridement ranged from 15 cm×10 cm to 24 cm×15 cm. Three patients were treated with flow-through descending branch of lateral circumflex femoral artery flap and great saphenous vein for repairing wounds of wrist and reconstruction of ulnar and radial artery. Two patients were treated with flow-through descending branch of lateral circumflex femoral artery flap for repairing wounds of wrist and reconstruction of ulnar artery. The dissected flaps ranged from 16 cm×12 cm to 26 cm×16 cm and the length of bridging vessel ranged from 15 to 21 cm. Results: The flow-through descending branch of lateral circumflex femoral artery flaps of five patients survived well. Wounds of 4 patients healed and wounds of 1 patient with infection under the flap on 3 days after operation healed after changing wound dressing and undergoing debridement for 2 weeks. After the operation, wrists and hands of 5 patients had adequate blood supply and ulnar and radial artery recovered patency. Follow-up of patients for 6 months to 1 year showed good flap appearance and adequate blood supply of burn hands. Conclusions: The flow-through descending branch of lateral

  11. Comparative in vitro dissolution study of carbamazepine immediate-release products using the USP paddles method and the flow-through cell system

    Science.gov (United States)

    Medina, José Raúl; Salazar, Dulce Karina; Hurtado, Marcela; Cortés, Alma Rosa; Domínguez-Ramírez, Adriana Miriam

    2013-01-01

    Dissolution profiles of four carbamazepine immediate-release generic products (200 mg tablets) and the reference product Tegretol® were evaluated using the USP paddles method and an alternative method with the flow-through cell system, USP Apparatus 4. Under official conditions all products met the Q specification, dissolution profiles of generic products were similar to the dissolution profile of the reference product (f2 > 50) and model-independent parameters showed non significant differences to the reference product except mean dissolution time for product A (p < 0.05). On the other hand, when the flow-through cell system was used, none of the products met the pharmacopeial specification at 15 min and product A did not reach dissolution criteria at 60 min, dissolution profiles of all generic products were not similar to the reference product profile (f2 < 50) and all model-independent parameters showed significant differences compared to the reference product (p < 0.05). Weibull’s model was more useful for adjusting the dissolution data of all products in both USP apparatuses and Td values showed significant differences compared to the reference product (p < 0.05) when USP Apparatus 4 was used. These results indicate that the proposed method, using the flow-through cell system, is more discriminative in evaluating both, rate and extent of carbamazepine dissolution process from immediate-release generic products. PMID:24648826

  12. Thermofluid experiments for Fusion Reactor Safety. Visualization of exchange flows through breaches of a vacuum vessel in a fusion reactor under the LOVA condition

    International Nuclear Information System (INIS)

    Fujii, Sadao; Shibazaki, Hiroaki; Takase, Kazuyuki; Kunugi, Tomoaki.

    1997-01-01

    Exchange flow rates through breaches of a vacuum vessel in a fusion reactor under the LOVA (Loss of VAcuum event) conditions were measured quantitatively by using a preliminary LOVA apparatus and exchange flow patterns over the breach were visualized qualitatively by smoke. Velocity distributions in the exchange flows were predicted from the observed flow patterns by using the correlation method in the flow visualization procedures. Mean velocities calculated from the predicted velocity distributions at the outside of the breach were in good agreement with the LOVA experimental results when the exchange flow velocities were low. It was found that the present flow visualization and the image processing system might be an useful procedure to evaluate the exchange flow rates. (author)

  13. A study of multi-phase flow through the cathode side of an interdigitated flow field using a multi-fluid model

    DEFF Research Database (Denmark)

    Berning, Torsten; Odgaard, Madeleine; Kær, Søren Knudsen

    2010-01-01

    This work presents a study of multi-phase flow through the cathode side of a polymer electrolyte membrane fuel cell employing an interdigitated flow field plate. A previously published model has been extended in order to account for phase change kinetics, and a comparison between the interdigitated....... The additional compressor work due to the increased pressure loss will only slightly increase, and this may be offset by operating at lower stoichiometries as the interdigitated design is less mass transfer controlled, which means that the overall efficiency of the interdigitated arrangement will be higher...

  14. A Flow-Through High-Pressure Electrical Conductance Cell for Determining of Ion Association of Aqueous Electrolyte Solutions at High Temperature and Pressure

    Energy Technology Data Exchange (ETDEWEB)

    Bianchi, H.; Ho, P.C.; Palmer, D.A.; Wood, R.H.

    1999-09-12

    A flow-through high-pressure electrical conductance cell was designed and constructed to measure limiting molar conductances and ion association constants of dilute aqueous solutions with high precision at high temperatures and pressures. The basic concept of the cell employs the principle developed at the University of Delaware in 1995, but overall targets higher temperatures (to 600 C) and pressures (to 300 MPa). At present the cell has been tested by measuring aqueous NaCl and LiOH solutions (10{sup {minus}3} to 10{sup {minus}5} mol.kg{sup {minus}1}) to 405 C and 33 MPa with good results.

  15. Autohydrolysis pretreatment of Arundo donax: a comparison between microwave-assisted batch and fast heating rate flow-through reaction systems.

    Science.gov (United States)

    Galia, Alessandro; Schiavo, Benedetto; Antonetti, Claudia; Galletti, Anna Maria Raspolli; Interrante, Leonardo; Lessi, Marco; Scialdone, Onofrio; Valenti, Maria Grazia

    2015-01-01

    Autohydrolysis of lignocellulosic biomass in liquid hot water has been widely studied owing to its high efficiency and relatively low cost. In the perspective of industrial applications, continuous or semi-continuous processes are more interesting than batch systems. Moreover, microwave heating of pretreatment systems has been proposed to intensify the kinetics of the process. In this study, the autohydrolysis of Arundo donax was performed in pure liquid hot water using a microwave-heated batch reactor and a semi-continuous flow-through reaction system with fast heating rate at the same operating conditions with the aim of performing a systematic comparison between the two different experimental apparatuses. The effect of process temperature and time, biomass to water mass to volume ratio and water flow rate on the concentration and yield of hydrolysis products was investigated. The flow-through set-up allowed us to reach biomass solubilization up to 44.5 wt% on dry basis, while the batch system stopped at 34.5 wt% suggesting that the mass transfer could be the rate-determining step in the solubilization of the constituting biopolymers. For example, in the flow-through layout, using a flow rate of 3.5 mL/min at 200 °C with 20 min of processing time, quantitative recovery of hemicellulose was obtained with limited formation of degradation products. Interestingly, higher cellulose/hemicellulose extraction ratios were found using the microwave-assisted batch reactor. FTIR analyses of the solid residues recovered after the pretreatment offered independent information on the fractions of liquefied biopolymers complementary to those derived from HPLC and UV-Vis spectroscopy. Collected experimental results indicated that the flow-through system can be adopted to obtain complete solubilization of the hemicellulose fraction of Arundo donax addressing the product distribution in soluble compounds towards fermentable sugars with limited formation of sugar degradation

  16. Flow-through polymerase chain reaction inside a seamless 3D helical microreactor fabricated utilizing a silicone tube and a paraffin mold.

    Science.gov (United States)

    Wu, Wenming; Trinh, Kieu The Loan; Lee, Nae Yoon

    2015-03-07

    We introduce a new strategy for fabricating a seamless three-dimensional (3D) helical microreactor utilizing a silicone tube and a paraffin mold. With this method, various shapes and sizes of 3D helical microreactors were fabricated, and a complicated and laborious photolithographic process, or 3D printing, was eliminated. With dramatically enhanced portability at a significantly reduced fabrication cost, such a device can be considered to be the simplest microreactor, developed to date, for performing the flow-through polymerase chain reaction (PCR).

  17. Simultaneous release of diclofenac sodium and papaverine hydrochloride from tablets and pellets using the flow-through cell apparatus described by dimensionless equations.

    Science.gov (United States)

    Kasperek, Regina

    2011-01-01

    The release of diclofenac sodium and papaverine hydrochloride from tablets and pellets using the flow-through cell apparatus was studied. The influence of excipients and of a size of the solid dosage forms on the amount of the released substances at the intervals of time using the different rates of flow of the dissolution medium was investigated. Physical parameters corresponding to the dissolution process as the mass transfer coefficient, the thickness of the boundary diffusion layer and the concentration of the saturated solution at this layer were calculated. The results of release were described by dimensionless equations.

  18. On Combined Effects of Heat Transfer and Chemical Reaction for the Flow through an Asymmetric Channel with Orthogonally Deformable Porous Walls

    Directory of Open Access Journals (Sweden)

    Syed Tauseef Mohyud-Din

    2016-01-01

    Full Text Available The combined effects of heat transfer and chemical reaction are studied for the flow through a semi-infinite asymmetric channel with orthogonally deformable porous walls. The similarity transforms have been used to reduce the conservation laws to a corresponding system of nonlinear ordinary differential equations. The resulting equations are solved, both analytically and numerically, by using Homotopy Analysis Method (HAM and the fourth-order Runge-Kutta (RK-4 method, respectively. The convergence of the analytical solution is assured through the so-called total squared residual error analysis. The optimal values of auxiliary parameters are obtained by minimizing the total squared residual error.

  19. MODELING OF FLOW THROUGH A VERTICAL PERFORATED PIPE IN THE BEACH, AND THE MORPHODYNAMIC INTERPRETATION: THE PRESSURE EQUALIZATION MODULE SYSTEM

    DEFF Research Database (Denmark)

    Fredsøe, Jørgen

    2009-01-01

    It has been suggested that vertical perforated tubes placed below the beach surface will increase the drainage of the beach, and hence increase the deposition of sand on the beach. The system is called the PEM-system, Pressure Equalization System, and the Danish company SIC (www.shore.dk) is doing...... the marketing. Although it for a coastal engineer seems obvious that such a device can’t drain the beach (nearly no driving forces ), SIC has succeeded in installing the system in more than 75 locations around the world (according to the company). In Denmark a full scale experiment at the exposed west coast has...

  20. Structural characterisation of pretreated solids from flow-through liquid hot water treatment of sugarcane bagasse in a fixed-bed reactor.

    Science.gov (United States)

    Reddy, Prashant; Lekha, Prabashni; Reynolds, Wienke; Kirsch, Christian

    2015-05-01

    Untreated sugarcane bagasse and sugarcane bagasse pretreated with flow-through liquid hot water (LHW) treatment (170-207°C and 204-250 ml/min) in a fixed-bed reactor have been structurally characterised. Field emission gun scanning electron microscopy (FEG-SEM) and transmission electron microscopy (TEM) were used to investigate changes in the residues, in particular due to the fate of lignin. FEG-SEM results show that the LHW treatment modified the surface morphology of the pretreated bagasse with lignin droplets being observed on the fibre surface. TEM showed an increase in the plant cell wall porosity and lignin migration across the plant cell wall. Increases in pretreatment temperature were observed to increase the average size and density of lignin droplets on the fibre surface. The results provide evidence that for LHW flow-through treatment, just as for batch treatment, lignin repolymerisation and deposition on the surface of pretreated sugarcane bagasse is an important consideration. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Numerical and experimental investigations on flow through perforated plates similar to the ones of the bottom end piece of nuclear reactors

    International Nuclear Information System (INIS)

    Barros Filho, Jose A.; Navarro, Moyses A.; Santos, Andre A. Campagnole dos

    2008-01-01

    There is an increasing interest in the application of three dimensional computational fluid dynamics (CFD) codes in the design and safety analysis of nuclear power plants. At present, the main objective with respect to CFD codes is generally to improve confidence in the available analysis tools and to achieve a more reliable approach to safety relevant issues. Aiming towards these goals, we present here the results of the first part of a research program devised to develop and validate a CFD methodology to simulate the water flow through perforated plates with geometry similar to the ones of the bottom end piece of the fuel elements of a Pressurized Water Reactor. This component drives the coolant into the core, promotes an adequate mixing of dissolved substances and holds the fuel assembly mechanically in place. It accounts for a great part of the pressure loss through the bottom end piece. We present here the experimental pressure loss of water flow through perforated plates where geometric features like diameter of holes and inlet chamfers were evaluated. The recovering pressure profile downstream of the plates was also measured. The experimental results were compared with numerical modeling performed with the commercial code CFX 11.0. (author)

  2. Characteristics of time-varying intracranial pressure on blood flow through cerebral artery: A fluid-structure interaction approach.

    Science.gov (United States)

    Syed, Hasson; Unnikrishnan, Vinu U; Olcmen, Semih

    2016-02-01

    Elevated intracranial pressure is a major contributor to morbidity and mortality in severe head injuries. Wall shear stresses in the artery can be affected by increased intracranial pressures and may lead to the formation of cerebral aneurysms. Earlier research on cerebral arteries and aneurysms involves using constant mean intracranial pressure values. Recent advancements in intracranial pressure monitoring techniques have led to measurement of the intracranial pressure waveform. By incorporating a time-varying intracranial pressure waveform in place of constant intracranial pressures in the analysis of cerebral arteries helps in understanding their effects on arterial deformation and wall shear stress. To date, such a robust computational study on the effect of increasing intracranial pressures on the cerebral arterial wall has not been attempted to the best of our knowledge. In this work, fully coupled fluid-structure interaction simulations are carried out to investigate the effect of the variation in intracranial pressure waveforms on the cerebral arterial wall. Three different time-varying intracranial pressure waveforms and three constant intracranial pressure profiles acting on the cerebral arterial wall are analyzed and compared with specified inlet velocity and outlet pressure conditions. It has been found that the arterial wall experiences deformation depending on the time-varying intracranial pressure waveforms, while the wall shear stress changes at peak systole for all the intracranial pressure profiles. © IMechE 2015.

  3. The effect of a large upstream bluff body on the flow through and around an array of cylinders

    Science.gov (United States)

    Klettner, Christian

    2015-11-01

    Risers from the sea floor to installations at the sea surface are an integral part of the flow assurance of deep sea oil exploration, which has become necessary in the last decade. These risers are subjected to various hydrodynamic forcing, particularly sea currents, wakes of upstream installation members and surface waves, which can result in vortex or wake induced vibrations and these in turn can result in riser fatigue or collision. The free stream flow past groups of cylinders has been studied numerically in two- and three-dimensions for Re ~ O (103) (based on the cylinder diameter) by Nicolle & Eames (2011) (direct numerical simulations) and Chang & Constantinescu (2015) (large eddy simulations) respectively. In this study we will be focusing on the first two aspects listed above, specifically laboratory experiments and high resolution numerical simulations will be performed to investigate the effect of an upstream truss on an array of cylinders. The main diagnostic will be how varying the void fraction of the array of cylinders affects the frequency and magnitude of the drag and lift forces on the cylinders.

  4. Experimental study of gas–liquid two-phase flow through packed bed under natural circulation conditions

    International Nuclear Information System (INIS)

    Chen, Shao-Wen; Miwa, Shuichiro; Griffiths, Matt

    2016-01-01

    Dry-out phenomena in packed beds or porous media may cause a significant digression of cooling/reaction performance in heat transfer/chemical reactor systems. One of the phenomena responsible for the dry-out in packed beds is known as the counter-current flow limitation (CCFL). In order to investigate the CCFL phenomena induced by gas–liquid two-phase flow in packed beds inside a pool, a natural circulation packed bed test facility was designed and constructed. A total of 27 experimental conditions covering various packing media sizes (sphere diameters: 3.0, 6.4 and 9.5 mm), packed bed heights (15, 35 and 50 cm) and water level heights (1.0, 1.5 and 2.0 m) were tested to examine the CCFL criteria with adiabatic air–water two-phase flow under natural circulation conditions. Both CCFL and flow reversal phenomena were observed, and the experimental data including instantaneous and time-averaged void fraction, differential pressure and superficial gas–liquid velocities were collected. The CCFL criteria were determined when periodical oscillations of void fraction and differential pressure appear. In addition, the Wallis correlation for CCFL was utilized for data analysis, and the Wallis coefficient, C, was determined experimentally from the packed bed CCFL tests. Compared to the existing data-sets in literature, the higher C values obtained in the present experiment suggest a possibly higher dry-out heat flux for natural circulation debris systems, which may be due to the water supply from both top and bottom surfaces of the packed beds. Considering the effects of bed height and hydraulic diameter of the packing media, a newly developed model for the Wallis coefficient, C, under natural circulation CCFL is presented. The present model can predict the experimental data with an averaged absolute error of ±7.9%. (author)

  5. Initial characterization of carbon flows through microbial communities in Beowulf spring, an acidic hot spring in Yellowstone National Park

    Science.gov (United States)

    Kreuzer, H.; Moran, J.; Ehrhardt, C.; Melville, A.; Kranz, A.; Inskeep, W. P.

    2011-12-01

    of a heterotrophic component in the system but the lack of a direct one-to-one isotopic correlation suggest there is an additional carbon input. We are performing a series of stable isotope probing experiments with microbial mats extracted from the spring to determine whether autotrophy may be a major carbon source in the system. Identifying the major active carbon pools and potential geochemical and microbial carbon links will illuminate carbon cycling in this system and should provide insights into how energy is transferred from key chemolithotrophic reactions to other components of the microbial system.

  6. The effects of Soret and Dufour, chemical reaction, Hall and ion currents on magnetized micropolar flow through co-rotating cylinders

    Directory of Open Access Journals (Sweden)

    Nagaraju Gajjela

    2017-11-01

    Full Text Available The influence of cross diffusions, Hall and Ion slip of a dissipative magnetized micropolar fluid flow through an infinite concentric rotating vertical cylinders were investigated in addition to the first order chemical reaction. Cylinders are taken into account for Isothermal (constant temperature wall condition and mixed gradient condition at inner cylinder, while convection cooling and constant wall concentration condition is taken at outer cylinder. The governing equations in cylindrical polar coordinates are coupled ordinary differential equations (ODEs and are solved numerically with help of Shooting method with fourth order Runge Kutta method. A parametric study illustrating the influence of the emerging parameters on flow, heat and mass transfer components as well as on Skin Friction, Nusselt number and Sherwood number through graphical illustrations.

  7. Rapid identification of Candida spp. frequently involved in invasive mycoses by using flow-through hybridization and Gene Chip (FHGC) technology.

    Science.gov (United States)

    Li, Chen; Ding, Xiurong; Liu, Zhizhong; Zhu, Juanjuan

    2017-01-01

    The incidence of invasive fungal infections in immunocompromised patients has increased in recent decades. Rapid and accurate identification of these pathogenic fungi is crucial for initiating a timely, safe, and effective antifungal therapy. Here we developed a microarray based on flow-through hybridization gene chip technology. The microarray was tested for its specificity using a panel of reference and blinded clinical isolates. The results proved that this microarray was highly discriminative, leading to the unequivocal identification of each species, including Candida famata and the highly related species Candida parapsilosis, Candida orthopsilosis, and Candida metapsilosis. This new system represents a reliable method that is of potential use in clinical laboratories for the simultaneous detection and identification of the most common pathogenic fungi. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. On the solution of the differential equation occurring in the problem of heat convection in laminar flow through a tube with slip—flow

    Directory of Open Access Journals (Sweden)

    Xanming Wang

    1996-01-01

    Full Text Available A technique is developed for evaluation of eigenvalues in solution of the differential equation d2y/dr2+(1/rdy/dr+λ2(β−r2y=0 which occurs in the problem of heat convection in laminar flow through a circular tube with silp-flow (β>1. A series solution requires the expansions of coeffecients involving extremely large numbers. No work has been reported in the case of β>1, because of its computational complexity in the evaluation of the eigenvalues. In this paper, a matrix was constructed and a computational algorithm was obtained to calculate the first four eigenvalues. Also, an asymptotic formula was developed to generate the full spectrum of eigenvalues. The computational results for various values of β were obtained.

  9. Analysis of the laminar Newtonian fluid flow through a thin fracture modelled as a fluid-saturated sparsely packed porous medium

    Energy Technology Data Exchange (ETDEWEB)

    Pazanin, Igor [Zagreb Univ. (Croatia). Dept. of Mathematics; Siddheshwar, Pradeep G. [Bangalore Univ., Bengaluru (India). Dept. of Mathematics

    2017-06-01

    In this article we investigate the fluid flow through a thin fracture modelled as a fluid-saturated porous medium. We assume that the fracture has constrictions and that the flow is governed by the prescribed pressure drop between the edges of the fracture. The problem is described by the Darcy-Lapwood-Brinkman model acknowledging the Brinkman extension of the Darcy law as well as the flow inertia. Using asymptotic analysis with respect to the thickness of the fracture, we derive the explicit higher-order approximation for the velocity distribution. We make an error analysis to comment on the order of accuracy of the method used and also to provide rigorous justification for the model.

  10. Measuring of electrical changes induced by in situ combustion through flow-through electrodes in a laboratory sample of core material

    Science.gov (United States)

    Lee, David O.; Montoya, Paul C.; Wayland, Jr., James R.

    1986-01-01

    Method and apparatus are provided for obtaining accurate dynamic measurements for passage of phase fronts through a core sample in a test fixture. Flow-through grid structures are provided for electrodes to permit data to be obtained before, during and after passage of a front therethrough. Such electrodes are incorporated in a test apparatus for obtaining electrical characteristics of the core sample. With the inventive structure a method is provided for measurement of instabilities in a phase front progressing through the medium. Availability of accurate dynamic data representing parameters descriptive of material characteristics before, during and after passage of a front provides a more efficient method for enhanced recovery of oil using a fire flood technique.

  11. Integration effects of underwing forward- and rearward-mounted separate-flow, flow-through nacelles on a high-wing transport

    Science.gov (United States)

    Lamb, M.; Abeyounis, W. K.

    1986-01-01

    An experimental investigation was conducted in the Langley 16-Foot Transonic Tunnel at free-stream Mach numbers from 0.70 to 0.82 and angles of attack from -2.5 to 4.0 degrees to determine the integration effects of pylon-mounted underwing forward and rearward separate-flow, flow-through nacelles on a high-wing transonic transport configuration. The results showed that the installed drag of the nacelle/pylon in the rearward location was slightly less than that of the nacelle/pylon in the forward location. This reduction was due to the reduction in calculated skin friction of the nacelle/pylon configuration. In all cases the combined value of form, wave, and interference drag was excessively high. However, the configuration with the nacelle/pylon in a rearward location produced an increase in lift over that of the basic wing-body configuration.

  12. [The clinical experience with MARS and Prometheus procedures].

    Science.gov (United States)

    Hydzik, Piotr; Gawlikowski, Tomasz; Ciszowski, Krzysztof; Sułlek, Monika

    2007-01-01

    Based on the hypothesis, that extracorporeal removal of endo- and egzogenic substances should be beneficial to the clinical course of the patient in liver failure or poisoned, treatment systems were evaluatedbased on the two concepts: (1) blood dialysis against albumin dialysate--Molecular Adsorbent Recirculating System (MARS), Single Pass Albumin Dialysis (SPAD), Continuous Veno-Venous Haemodiafiltration (CWHDF); (2) selective albumin filtration and adsorption combined with haemodialysis--Fractioned Plasma Separation and Adsorption-Prometheus. We present our own experiences with MARS and Prometheus procedures between 2003-2006 years.

  13. Development of a flow-through enzyme immunoassay and application in screening green coffee samples for ochratoxin A with confirmation by high-performance liquid chromatography.

    Science.gov (United States)

    Sibanda, L; De Saeger, S; Bauters, T G; Nelis, H J; Van Peteghem, C

    2001-10-01

    A flow-through enzyme immunoassay has been developed for the screening of green coffee bean samples for ochratoxin A (OA) and was later used in a survey on OA in green coffee from different countries. The test has a sensitivity of 8 ng/g, and calculated recoveries ranged from 70 to 89% and from 86 to 95% for spiked and naturally contaminated samples, respectively. There were no significant differences in within-day and between-day assay performance (P > 0.05). Green coffee samples (15 Arabica and 7 Robusta) received from an international coffee trader were analyzed for intrinsic fungal contamination, screened for OA, and subsequently confirmed by high-performance liquid chromatography (HPLC). All 22 samples were contaminated by fungal species of the genus Aspergillus, while Penicillium species were isolated from a mere 13.6% of the total number of samples. Isolates were tested for their ability to produce OA, and only 3.9% were positive. There was no correlation between occurrence of OA-producing isolates and levels of OA in contaminated samples. Results of the screening procedure showed that 4 of the 22 samples were contaminated with 8 ng/g or higher. The HPLC method confirmed that the OA levels ranged from 27 to 168 ng/g. A fifth sample, which was shown to be negative during screening, had an OA concentration of 4 ng/g. There were no false negatives or positives recorded, and the flow-through enzyme immunoassay results correlated with those obtained by HPLC.

  14. Boiling flow through diverging microchannel

    Indian Academy of Sciences (India)

    118–. 1182 kg/m2-s) and heat flux (1.6–19.2 W/cm2) on single and two-phase pressure drop and average heat transfer coefficient has been studied. Concurrently, flow visu- alization is carried out to document the various flow regimes and to ...

  15. Boiling flow through diverging microchannel

    Indian Academy of Sciences (India)

    Effect of mass flux (118–1182 kg/m2-s) and heat flux (1.6–19.2 W/cm2) on single and two-phase pressure drop and average heat transfer coefficient has been studied. Concurrently, flow visualization is carried out to document the various flow regimes and to correlate the pressure drop and average heat transfer coefficient ...

  16. Boiling flow through diverging microchannel

    Indian Academy of Sciences (India)

    affected by high transient heat flux conditions (153 W/cm2), which can be successfully mitigated by employing ... channel dimensions so that a higher surface area to volume ratio can be achieved. However, ..... where xe is the exit quality and Rel is the Reynolds number corresponding to the total inlet liquid mass flux and ...

  17. Flow-through solid-phase based optical sensor for the multisyringe flow injection trace determination of orthophosphate in waters with chemiluminescence detection

    International Nuclear Information System (INIS)

    Morais, Ines P.A.; Miro, Manuel; Manera, Matias; Estela, Jose Manuel; Cerda, Victor; Souto, M. Renata S.; Rangel, Antonio O.S.S.

    2004-01-01

    In this work, a novel flow-through solid-phase based chemiluminescence (CL) optical sensor is described for the trace determination of orthophosphate in waters exploiting the multisyringe flow injection analysis (MSFIA) concept with multicommutation. The proposed time-based injection flow system relies upon the in-line derivatisation of the analyte with ammonium molybdate in the presence of vanadate, and the transient immobilisation of the resulting heteropolyacid in a N-vinylpyrrolidone/divinylbenzene copolymer packed spiral shape flow-through cell located in front of the window of a photomultiplier tube. The simultaneous injection of well-defined slugs of luminol in alkaline medium and methanol solution towards the packed reactor is afterwards performed by proper switching of the solenoid valves. Then, the light emission from the luminol oxidation by the oxidant species retained onto the sorbent material is readily detected. At the same time, the generated molybdenum-blue compound is eluted by the minute amount of injected methanol, rendering the system prepared for a new measuring cycle. Therefore, the devised sensor enables the integration of the solid-phase CL reaction with elution and detection of the emitted light without the typical drawbacks of the molybdenum-blue based spectrophotometric procedures regarding the excess of molybdate anion, which causes high background signals due to its self-reduction. The noteworthy features of the developed CL-MSFIA system are the feasibility to accommodate reactions with different pH requirements and the ability to determine trace levels of orthophosphate in high silicate content samples (Si/P ratios up to 500). Under the optimised conditions, a dynamic linear range from 5 to 50 μg P l -1 for a 1.8 ml sample, repeatability better than 3.0% and a quantification limit of 4 μg P l -1 were attained. The flowing stream system handles 11 analysis h -1 and has been successfully applied to the determination of trace levels of

  18. A Flow-Through Cell Electroporation Device for Rapidly and Efficiently Transfecting Massive Amounts of Cells in vitro and ex vivo

    Science.gov (United States)

    Zhao, Deyao; Huang, Dong; Li, Yang; Wu, Mengxi; Zhong, Wenfeng; Cheng, Qiang; Wang, Xiaoxia; Wu, Yidi; Zhou, Xiao; Wei, Zewen; Li, Zhihong; Liang, Zicai

    2016-01-01

    Continuous cell electroporation is an appealing non-viral approach for genetically transfecting a large number of cells. Yet the traditional macro-scale devices suffer from the unsatisfactory transfection efficiency and/or cell viability due to their high voltage, while the emerging microfluidic electroporation devices is still limited by their low cell processing speed. Here we present a flow-through cell electroporation device integrating large-sized flow tube and small-spaced distributed needle electrode array. Relatively large flow tube enables high flow rate, simple flow characterization and low shear force, while well-organized needle array electrodes produce an even-distributed electric field with low voltage. Thus the difficulties for seeking the fine balance between high flow rate and low electroporation voltage were steered clear. Efficient in vitro electrotransfection of plasmid DNA was demonstrated in several hard-to-transfect cell lines. Furthermore, we also explored ex vivo electroporated mouse erythrocyte as the carrier of RNA. The strong ability of RNA loading and short exposure time of freshly isolated cells jointly ensured a high yield of valid carrier erythrocytes, which further successfully delivered RNA into targeted tissue. Both in vitro and ex vivo electrotransfection could be accomplished at high cell processing speed (20 million cells per minute) which remarkably outperforms previous devices.

  19. Measurements of 220Rn in air using a flow-through Lucas cell and multiple time analysis of recorded pulse events

    International Nuclear Information System (INIS)

    Falk, R.; Moere, H.; Nyblom, L.

    1992-01-01

    A multiple time analysis technique has successfully been applied for measurements of environmental levels of 220 Rn using a flow-through Lucas radon detector. The method is based on selective alpha counting of the short-lived nuclide 216 Pu. Owing to its short half-life (0.145 s), the alpha particle emitted at the decay of a 220 Rn atom will, within a fraction of a second, be followed by an alpha particle from the decay of 216 Po. By measuring the time interval between successive alpha counts followed by a multiple time analysis, the 216 Po activity and thereby the 220 Rn activity can be calculated. The method applied to a commercial instrument with a 160 ml Lucas cell as detector shows that a mean 220 Rn air concentration of less than 20 Bq.m -3 can easily be determined even if the 222 Rn air concentration is 10 times higher and varies. At lower 222 Rn levels a 220 Rn concentration less than 1 Bq.m -3 can be assessed using this technique. The method will be described together with some examples of its practical use. (author)

  20. A comparative study of scale-adaptive and large-eddy simulations of highly swirling turbulent flow through an abrupt expansion

    International Nuclear Information System (INIS)

    Javadi, Ardalan; Nilsson, Håkan

    2014-01-01

    The strongly swirling turbulent flow through an abrupt expansion is investigated using highly resolved LES and SAS, to shed more light on the stagnation region and the helical vortex breakdown. The vortex breakdown in an abrupt expansion resembles the so-called vortex rope occurring in hydro power draft tubes. It is known that the large-scale helical vortex structures can be captured by regular RANS turbulence models. However, the spurious suppression of the small-scale structures should be avoided using less diffusive methods. The present work compares LES and SAS results with the experimental measurement of Dellenback et al. (1988). The computations are conducted using a general non-orthogonal finite-volume method with a fully collocated storage available in the OpenFOAM-2.1.x CFD code. The dynamics of the flow is studied at two Reynolds numbers, Re=6.0×10 4 and Re=10 5 , at the almost constant high swirl numbers of Sr=1.16 and Sr=1.23, respectively. The time-averaged velocity and pressure fields and the root mean square of the velocity fluctuations, are captured and investigated qualitatively. The flow with the lower Reynolds number gives a much weaker outburst although the frequency of the structures seems to be constant for the plateau swirl number

  1. Cost-effective flow-through nanohole array-based biosensing platform for the label-free detection of uropathogenic E. coli in real time.

    Science.gov (United States)

    Gomez-Cruz, Juan; Nair, Srijit; Manjarrez-Hernandez, Angel; Gavilanes-Parra, Sandra; Ascanio, Gabriel; Escobedo, Carlos

    2018-05-30

    Rapid, inexpensive and sensitive detection of uropathogenic Escherichia coli (UPEC), a common cause of ascending urinary tract infections (UTIs) including cystitis and pyelonephritis, is critical given the increasing number of cases and its recurrence worldwide. In this paper, we present a label-free nanoplasmonic sensing platform, built with off-the-shelf optical and electronic components, which can detect intact UPEC at concentrations lower than the physiological limit for UTI diagnosis, in real time. The sensing platform consists of a red LED light source, lens assembly, CMOS detector, Raspberry Pi interface in conjugation with a metallic flow-through nanohole array-based sensor. Detection is achieved exploiting nanoplasmonic phenomena from the nanohole arrays through surface plasmon resonance imaging (SPRi) technique. The platform has a bulk sensitivity of 212 pixel intensity unit (PIU)/refractive index unit (RIU), and a resolution in the order of 10 -6 RIU. We demonstrate capture and detection of UPEC with a detection limit of ~100 CFU/ml - a concentration well below the threshold limit for UTI diagnosis in clinical samples. We also demonstrate detection of UPEC in spiked human urine samples for two different concentrations of bacteria. This work is particularly relevant for point-of-care applications, especially for regions around the world where accessibility to medical facilities is heavily dependent upon economy, and availability. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Comparative release studies on suppositories using the basket, paddle, dialysis tubing and flow-through cell methods I. Acetaminophen in a lipophilic base suppository.

    Science.gov (United States)

    Hori, Seiichi; Kawada, Tsubasa; Kogure, Sanae; Yabu, Shinako; Mori, Kenji; Akimoto, Masayuki

    2017-02-01

    The release characteristics of lipophilic suppositories containing acetaminophen (AAP) were examined using four types of dissolution methods: the basket, paddle, dialysis tubing (DT) and flow-through cell (FTC) methods. The suitability of each apparatus for quality control in AAP compounded suppositories was evaluated using statistical procedures. More than 80% of the drug was released over 60 min in all the release methods studied, with the exception of the basket method. Reproducible and faster release was achieved using the paddle method at 100 and 200 rpm, whereas poor release occurred with the basket method. The mean dissolution time (MDT), maximum dissolved quantity of AAP at the end of the sampling time (Q) and dissolution efficiency (DE) were calculated by model-independent methods. The FTC method with a single chamber used in this study was also appreciable for AAP suppositories (Q of 100%, MDT of 71-91 min and DE of 75-80%). The DT apparatus is considered similar to the FTC apparatus from a quality control perspective for judging the release properties of lipophilic base suppositories containing AAP. However, even the single chamber FTC used in this study has potential as an in vitro drug release test for suppositories. The comparative dissolution method is expected to become one of the valuable tools for selecting an adequate dissolution test.

  3. Immobilization of Tyrosinase on (3-Aminopropyltriethoxysilane-Functionalized Carbon Felt-Based Flow-Through Detectors for Electrochemical Detection of Phenolic Compounds

    Directory of Open Access Journals (Sweden)

    Zheng Zhou

    2017-07-01

    Full Text Available Tyrosinase (TYR was covalently immobilized onto amino-functionalized carbon felt (CF surface via glutaraldehyde (GA. Prior to the TYR-immobilization, primary amino group was introduced to the CF surface by treatment with 3-aminopropyltriethoxysilane (APTES. The resulting TYR-immobilized CF was used as a working electrode unit of an electrochemical flow-through detector for mono- and di-phenolic compounds (i.e., catechol, p-cresol, phenol and p-chlorophenol. Additionally, flow injection peaks based on electroreduction of the enzymatically produced o-quinone species were detected at −0.05 V vs. Ag/AgCl. The resulting TYR/GA/APTES/CF biosensor responded well to all compounds tested with limits of detection range from 7.5 to 35 nmol−1 (based on three times S/N ratio. Moreover, such modified electrode exhibits good stability and reproducibility for catechol. No serious degradation of the peak current was found over 30 consecutive injections.

  4. Modeling and simulation of turbulent flows through a solar air heater having square-sectioned transverse rib roughness on the absorber plate.

    Science.gov (United States)

    Yadav, Anil Singh; Bhagoria, J L

    2013-01-01

    Solar air heater is a type of heat exchanger which transforms solar radiation into heat energy. The thermal performance of conventional solar air heater has been found to be poor because of the low convective heat transfer coefficient from the absorber plate to the air. Use of artificial roughness on a surface is an effective technique to enhance the rate of heat transfer. A CFD-based investigation of turbulent flow through a solar air heater roughened with square-sectioned transverse rib roughness has been performed. Three different values of rib-pitch (P) and rib-height (e) have been taken such that the relative roughness pitch (P/e = 14.29) remains constant. The relative roughness height, e/D, varies from 0.021 to 0.06, and the Reynolds number, Re, varies from 3800 to 18,000. The results predicted by CFD show that the average heat transfer, average flow friction, and thermohydraulic performance parameter are strongly dependent on the relative roughness height. A maximum value of thermohydraulic performance parameter has been found to be 1.8 for the range of parameters investigated. Comparisons with previously published work have been performed and found to be in excellent agreement.

  5. The influence of the tangential velocity of inner rotating wall on axial velocity profile of flow through vertical annular pipe with rotating inner surface

    Directory of Open Access Journals (Sweden)

    Sharf Abdusalam M.

    2014-03-01

    Full Text Available In the oil and gas industries, understanding the behaviour of a flow through an annulus gap in a vertical position, whose outer wall is stationary whilst the inner wall rotates, is a significantly important issue in drilling wells. The main emphasis is placed on experimental (using an available rig and computational (employing CFD software investigations into the effects of the rotation speed of the inner pipe on the axial velocity profiles. The measured axial velocity profiles, in the cases of low axial flow, show that the axial velocity is influenced by the rotation speed of the inner pipe in the region of almost 33% of the annulus near the inner pipe, and influenced inversely in the rest of the annulus. The position of the maximum axial velocity is shifted from the centre to be nearer the inner pipe, by increasing the rotation speed. However, in the case of higher flow, as the rotation speed increases, the axial velocity is reduced and the position of the maximum axial velocity is skewed towards the centre of the annulus. There is a reduction of the swirl velocity corresponding to the rise of the volumetric flow rate.

  6. Development of numerical simulation method for gas migration through highly-compacted bentonite using model of two-phase flow through deformable porous media

    International Nuclear Information System (INIS)

    Tanaka, Yukihisa

    2011-01-01

    In the current concept of repository for radioactive waste disposal, compacted bentonite will be used as an engineered barrier mainly for inhibiting migration of radioactive nuclides. Hydrogen gas can be generated inside of the engineered barrier by anaerobic corrosion of metals used for containers, etc. It is expected to be not easy for gas to entering into the bentonite as a discrete gaseous phase because the pore of compacted bentonite is so minute. Therefore it is necessary to investigate the effect of gas pressure generation and gas migration on the engineered barrier, peripheral facilities and ground. In this study, a method for simulating gas migration through the compacted bentonite is proposed. The proposed method can analyze coupled hydrological-mechanical processes using the model of two-phase flow through deformable porous media. Validity of the proposed analytical method is examined by comparing gas migration test results with the calculated results, which revealed that the proposed method can simulate gas migration behavior through compacted bentonite with accuracy. (author)

  7. Macroinvertebrates and fishes in the part of the Danube flowing through the Iron Gate national park and possibilities of their protection under in situ and ex situ conditions

    Directory of Open Access Journals (Sweden)

    Simić Vladica M.

    2004-01-01

    Full Text Available Comparison of the results of later investigations of the Danube in the part flowing through in the Iron Gate (Đerdap National Park with those of research conducted earlier (20 to 40 years ago shows that changes have occurred in regard to the presence and especially the abundance of certain hydrobionts on this sector of the river, a finding that applies to all groups examined. The paper discusses the potential and results of conservation measures realized through both legal regulations and medium-term plans for the advancement of fishing in this region. In addition to in situ study during the period from 1999 to 2003, a large number of species (especially of macroinvertebrates and fish were also investigated under artificial conditions (in the Kragujevac Aquarium in order to gain a better understanding of their ecological characteristics, especially their sensitivity to various environmental stress factors. The presented results indicate that weight of specimens and success of culturing under ex situ conditions are correlated with their sensitivity under natural conditions.

  8. Intergration effects of D-shaped, underwing, aft-mounted, separate-flow, flow-through nacelles on a high-wing transport

    Science.gov (United States)

    Lamb, Milton; Carlson, John R.; Pendergraft, Odis C., Jr.

    1987-01-01

    An experimental investigation was conducted in the Langley 16-Foot Transonic Tunnel at freestream Mach numbers from 0.70 to 0.82 and angles of attack from -3.0 to 4.0 deg to determine the integration effects of D-shaped, underwing, aft-mounted, separate-flow, flow-through nacelles on a high-wing transonic transport configuration. The results showed that the aft-mounted nacelle/pylon produced an increase in lift over that of the wing-body configuration by pressurizing much of the wing lower surface in front of the pylon. For the D-shaped nacelle, a substantial region of supersonic flow over the wing, aft of the lip of the nacelle, cancelled the reduction in drag caused by the increase in pressures ahead of the lip, to increase interference and form drag compared with a similar circular-shaped nacelle. The installed drag of the D=shaped nacelle was essentially the same as that of an aft-mounted circular nacelle from a previous investigation.

  9. The effect of sediment mimicking drill cuttings on deep water rhodoliths in a flow-through system: Experimental work and modeling.

    Science.gov (United States)

    Figueiredo, Marcia A O; Eide, Ingvar; Reynier, Marcia; Villas-Bôas, Alexandre B; Tâmega, Frederico T S; Ferreira, Carlos Gustavo; Nilssen, Ingunn; Coutinho, Ricardo; Johnsen, Ståle

    2015-06-15

    The impact of sediment coverage on two rhodolith-forming calcareous algae species collected at 100m water depth off the coast of Brazil was studied in an experimental flow-through system. Natural sediment mimicking drill cuttings with respect to size distribution was used. Sediment coverage and photosynthetic efficiency (maximum quantum yield of charge separation in photosystem II, ϕPSIImax) were measured as functions of light intensity, flow rate and added amount of sediment once a week for nine weeks. Statistical experimental design and multivariate data analysis provided statistically significant regression models which subsequently were used to establish exposure-response relationship for photosynthetic efficiency as function of sediment coverage. For example, at 70% sediment coverage the photosynthetic efficiency was reduced 50% after 1-2weeks of exposure, most likely due to reduced gas exchange. The exposure-response relationship can be used to establish threshold levels and impact categories for environmental monitoring. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. The effect of direct and counter-current flow-through delignification on enzymatic hydrolysis of wheat straw, and flow limits due to compressibility.

    Science.gov (United States)

    Pihlajaniemi, Ville; Sipponen, Mika Henrikki; Pastinen, Ossi; Nyyssölä, Antti; Laakso, Simo

    2016-12-01

    This article compares the processes for wheat straw lignocellulose fractionation by percolation, counter-current progressing batch percolation and batch reaction at low NaOH-loadings (3-6% of DM). The flow-through processes were found to improve delignification and subsequent enzymatic saccharification, reduce NaOH-consumption and allow reduction of thermal severity, whereas hemicellulose dissolution was unaffected. However, contrary to previous expectations, a counter-current process did not provide additional benefits to regular percolation. The compressibility and flow properties of a straw bed were determined and used for simulation of the packing density profile and dynamic pressure in an industrial scale column. After dissolution of 30% of the straw DM by delignification, a pressure drop above 100 kPa m -1 led to clogging of the flow due to compaction of straw. Accordingly, the maximum applicable feed pressure and volumetric straw throughput was determined as a function of column height, indicating that a 10 m column can be operated at a maximum feed pressure of 530 kPa, corresponding to an operation time of 50 min and a throughput of 163 kg m -3  h -1 . Biotechnol. Bioeng. 2016;113: 2605-2613. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  11. Simultaneous Analysis of Monovalent Anions and Cations with a Sub-Microliter Dead-Volume Flow-Through Potentiometric Detector for Ion Chromatography

    Science.gov (United States)

    Dumanli, Rukiye; Attar, Azade; Erci, Vildan; Isildak, Ibrahim

    2016-01-01

    A microliter dead-volume flow-through cell as a potentiometric detector is described in this article for sensitive, selective and simultaneous detection of common monovalent anions and cations in single column ion chromatography for the first time. The detection cell consisted of less selective anion- and cation-selective composite membrane electrodes together with a solid-state composite matrix reference electrode. The simultaneous separation and sensitive detection of sodium (Na+), potassium (K+), ammonium (NH4+), chloride (Cl−) and nitrate (NO3−) in a single run was achieved by using 98% 1.5 mM MgSO4 and 2% acetonitrile eluent with a mixed-bed ion-exchange separation column without suppressor column system. The separation and simultaneous detection of the anions and cations were completed in 6 min at the eluent flow-rate of 0.8 mL/min. Detection limits, at S/N = 3, were ranged from 0.2 to 1.0 µM for the anions and 0.3 to 3.0 µM for the cations, respectively. The developed method was successfully applied to the simultaneous determination of monovalent anions and cations in several environmental and biological samples. PMID:26786906

  12. Continuous esterification to produce biodiesel by SPES/PES/NWF composite catalytic membrane in flow-through membrane reactor: experimental and kinetic studies.

    Science.gov (United States)

    Shi, Wenying; He, Benqiao; Cao, Yuping; Li, Jianxin; Yan, Feng; Cui, Zhenyu; Zou, Zhiqun; Guo, Shiwei; Qian, Xiaomin

    2013-02-01

    A novel composite catalytic membrane (CCM) was prepared from sulfonated polyethersulfone (SPES) and polyethersulfone (PES) blend supported by non-woven fabrics, as a heterogeneous catalyst to produce biodiesel from continuous esterification of oleic acid with methanol in a flow-through mode. A kinetic model of esterification was established based on a plug-flow assumption. The effects of the CCM structure (thickness, area, porosity, etc.), reaction temperature and the external and internal mass transfer resistances on esterification were investigated. The results showed that the CCM structure had a significant effect on the acid conversion. The external mass transfer resistance could be neglected when the flow rate was over 1.2 ml min(-1). The internal mass transfer resistance impacted on the conversion when membrane thickness was over 1.779 mm. An oleic acid conversion kept over 98.0% for 500 h of continuous running. The conversions obtained from the model are in good agreement with the experimental data. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. 5.7  W cw single-frequency laser at 671  nm by single-pass second harmonic generation of a 17.2  W injection-locked 1342  nm Nd : YVO4 ring laser using periodically poled MgO : LiNbO3.

    Science.gov (United States)

    Koch, Peter; Ruebel, Felix; Bartschke, Juergen; L'huillier, Johannes A

    2015-11-20

    We demonstrate a continuous wave single-frequency laser at 671.1 nm based on a high-power 888 nm pumped Nd:YVO4 ring laser at 1342.2 nm. Unidirectional operation of the fundamental ring laser is achieved with the injection-locking technique. A Nd:YVO4 microchip laser serves as the injecting seed source, providing a tunable single-frequency power of up to 40 mW. The ring laser emits a single-frequency power of 17.2 W with a Gaussian beam profile and a beam propagation factor of M2beam profile and a beam propagation factor of M2lasers. This work opens possibilities in cold atoms experiments with lithium, allowing the use of larger ensembles in magneto-optical traps or higher diffraction orders in atomic beam interferometers.

  14. CO2 emissions and heat flow through soil, fumaroles, and steam heated mud pools at the Reykjanes geothermal area, SW Iceland

    International Nuclear Information System (INIS)

    Fridriksson, Thrainn; Kristjansson, Bjarni Reyr; Armannsson, Halldor; Margretardottir, Eygerour; Olafsdottir, Snjolaug; Chiodini, Giovanni

    2006-01-01

    Carbon dioxide emissions and heat flow through soil, steam vents and fractures, and steam heated mud pools were determined in the Reykjanes geothermal area, SW Iceland. Soil diffuse degassing of CO 2 was quantified by soil flux measurements on a 600 m by 375 m rectangular grid using a portable closed chamber soil flux meter and the resulting data were analyzed by both a graphical statistical method and sequential Gaussian simulations. The soil temperature was measured in each node of the grid and used to evaluate the heat flow. The heat flow data were also analyzed by sequential Gaussian simulations. Heat flow from steam vents and fractures was determined by quantifying the amount of steam emitted from the vents by direct measurements of steam flow rate. The heat loss from the steam heated mud pools was determined by quantifying the rate of heat loss from the pools by evaporation, convection, and radiation. The steam flow rate into the pools was calculated from the observed heat loss from the pools, assuming that steam flow was the only mechanism of heat transport into the pool. The CO 2 emissions from the steam vents and mud pools were determined by multiplying the steam flow rate from the respective sources by the representative CO 2 concentration of steam in the Reykjanes area. The observed rates of CO 2 emissions through soil, steam vents, and steam heated mud pools amounted to 13.5 ± 1.7, 0.23 ± 0.05, and 0.13 ± 0.03 tons per day, respectively. The heat flow through soil, steam vents, and mud pools was 16.9 ± 1.4, 2.2 ± 0.4, and 1.2 ± 0.1 MW, respectively. Heat loss from the geothermal reservoir, inferred from the CO 2 emissions through the soil amounts to 130 ± 16 MW of thermal energy. The discrepancy between the observed heat loss and the heat loss inferred from the CO 2 emissions is attributed to steam condensation in the subsurface due to interactions with cold ground water. These results demonstrate that soil diffuse degassing can be a more

  15. Automatic flow-through dynamic extraction: A fast tool to evaluate char-based remediation of multi-element contaminated mine soils.

    Science.gov (United States)

    Rosende, María; Beesley, Luke; Moreno-Jimenez, Eduardo; Miró, Manuel

    2016-02-01

    An automatic in-vitro bioaccessibility test based upon dynamic microcolumn extraction in a programmable flow setup is herein proposed as a screening tool to evaluate bio-char based remediation of mine soils contaminated with trace elements as a compelling alternative to conventional phyto-availability tests. The feasibility of the proposed system was evaluated by extracting the readily bioaccessible pools of As, Pb and Zn in two contaminated mine soils before and after the addition of two biochars (9% (w:w)) of diverse source origin (pine and olive). Bioaccessible fractions under worst-case scenarios were measured using 0.001 mol L(-1) CaCl2 as extractant for mimicking plant uptake, and analysis of the extracts by inductively coupled optical emission spectrometry. The t-test of comparison of means revealed an efficient metal (mostly Pb and Zn) immobilization by the action of olive pruning-based biochar against the bare (control) soil at the 0.05 significance level. In-vitro flow-through bioaccessibility tests are compared for the first time with in-vivo phyto-toxicity assays in a microcosm soil study. By assessing seed germination and shoot elongation of Lolium perenne in contaminated soils with and without biochar amendments the dynamic flow-based bioaccessibility data proved to be in good agreement with the phyto-availability tests. Experimental results indicate that the dynamic extraction method is a viable and economical in-vitro tool in risk assessment explorations to evaluate the feasibility of a given biochar amendment for revegetation and remediation of metal contaminated soils in a mere 10 min against 4 days in case of phyto-toxicity assays. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Dynamic flow-through sequential extraction for assessment of fractional transformation and inter-element associations of arsenic in stabilized soil and sludge

    International Nuclear Information System (INIS)

    Buanuam, Janya; Wennrich, Rainer

    2010-01-01

    A dynamic flow-through extraction system was applied for the first time to ascertain the fractional transformation and inter-element associations of arsenic in stabilized environmental solids, as exemplified by the partitioning of soil and sludge stabilized with three additives, namely MnO 2 , Ca(OH) 2 and FeSO 4 . The extraction system used not only gave fractionation data, but also the extraction profiles (extractograms) which were used for investigation of the breaking down of phases, kinetic releasing of As and elemental association between As and inorganic additives. Five geochemical fractions of As were elucidated by accommodation in the flow manifold of a modified Wenzel's sequential extraction scheme, well established for fractionation of arsenic. The results revealed that MnO 2 and FeSO 4 have a slight effect on As phase transformation for soil and sludge samples amended for one week whereas the addition of Ca(OH) 2 increases As mobility due to the desorption of As from the solid Fe-oxides phase. The significant change in fractional transformation after 8 weeks of incubation can be seen in MnO 2 -treated soil. There was an increase of 17% in the non-mobilizable As fraction in MnO 2 -treated soil. From extractograms, arsenic in untreated soil was found to be rapidly leached and concurrently released with Fe. This may be evidence that the release of As is dependent on the dissolution of amorphous Fe oxides. In MnO 2 -treated soil, a strong affinity was observed between Mn and As in the amorphous Fe/Al oxides fraction, and this plays an important role in slowing down the kinetics of As releasing.

  17. On-line continuous monitoring of glucose or lactate by ultraslow microdialysis combined with a flow-through nanoliter biosensor based on poly(m-phenylenediamine) ultra-thin polymer membrane as enzyme electrode

    NARCIS (Netherlands)

    Rhemrev-Boom, MM; Jonker, MA; Venema, K; Jobst, G; Tiessen, R; Korf, J

    2001-01-01

    A miniaturised flow-through biosensor with a cell volume of only a few nanoliters was developed in our laboratory. The biosensor can be directly coupled to a microdialysis or ultrafiltration probe. Sampling and continuous on-line monitoring can thus be carried out at submicroliter levels and as a

  18. A flow-through aqueous standard generation system for thin film microextraction investigations of UV filters and biocides partitioning to different environmental compartments.

    Science.gov (United States)

    Ahmadi, Fardin; Sparham, Chris; Pawliszyn, Janusz

    2017-11-01

    In this paper problems associated with preparation of aqueous standard of highly hydrophobic compounds such as partial precipitation, being lost on the surfaces, low solubility in water and limited sample volume for accurate determination of their distribution coefficients are addressed. The following work presents two approaches that utilize blade thin film microextraction (TFME) to investigate partitioning of UV filters and biocides to humic acid (dissolved organic carbon) and sediment. A steady-state concentration of target analytes in water was generated using a flow-through aqueous standard generation (ASG) system. Dialysis membranes, a polytetrafluoroethylene permeation tube, and a frit porous (0.5 μm) coated by epoxy glue were basic elements used for preparation of the ASG system. In the currently presented study, negligible depletion TFME using hydrophilic-lipophilic balance (HLB) and octadecyl silica-based (C18) sorbents was employed towards the attainment of free concentration values of target analytes in the studied matrices. Thin film geometry provided a large volume of extraction phase, which improved the sensitivity of the method towards highly matrix-bound analytes. Extractions were performed in the equilibrium regime so as to prevent matrix effects and with aims to reach maximum method sensitivity for all analytes under study. Partitioning of analytes on dissolved organic carbon (DOC) was investigated in ASG to facilitate large sample volume conditions. Binding percentages and DOC distribution coefficients (Log K DOC ) ranged from 20 to 98% and 3.71-6.72, respectively. Furthermore, sediment-water partition coefficients (K d ), organic-carbon normalized partition coefficients (Log K OC ), and DOC distribution coefficients (Log K DOC ) were investigated in slurry sediment, and ranged from 33 to 2860, 3.31-5.24 and 4.52-5.75 Lkg -1 , respectively. The obtained results demonstrated that investigations utilizing ASG and TFME can yield reliable binding

  19. RHIC/AGS Online Model Environments: Experiences and Design for AGS Modeling

    International Nuclear Information System (INIS)

    Brown, K.; Niederer, J.; Satogata, T.; Alai Tafti, A.; Tsoupas, N.; Zeijts, J. van

    1999-01-01

    The RHIC/AGS online modeling environment, a general client-server modeling package that supports cdev and straightforward integration of diverse computational modeling engines (CMEs), is being adapted to model the AGS and Booster at BNL. This implementation uses a version of MAD modified at BNL that allows traditional lattice structure analysis, single pass beam line analysis, multi-particle tracking, interactive graphics, and the use of field maps. The on-line model system is still under development, a real working prototype exists and is being tested. This paper describes the system and experience with its design and use for AGS and AGS Booster online modeling

  20. Simplified models of the symmetric single-pass parallel-plate counterflow heat exchanger: a tutorial.

    Science.gov (United States)

    Pickard, William F; Abraham-Shrauner, Barbara

    2018-03-01

    The heat exchanger is important in practical thermal processes, especially those of (i) the molten-salt storage schemes, (ii) compressed air energy storage schemes and (iii) other load-shifting thermal storage presumed to undergird a Smart Grid. Such devices, although central to the utilization of energy from sustainable (but intermittent) renewable sources, will be unfamiliar to many scientists, who nevertheless need a working knowledge of them. This tutorial paper provides a largely self-contained conceptual introduction for such persons. It begins by modelling a novel quantized exchanger, impractical as a device, but useful for comprehending the underlying thermophysics. It then reviews the one-dimensional steady-state idealization which demonstrates that effectiveness of heat transfer increases monotonically with (device length)/(device throughput). Next, it presents a two-dimensional steady-state idealization for plug flow and from it derives a novel formula for effectiveness of transfer; this formula is then shown to agree well with a finite-difference time-domain solution of the two-dimensional idealization under Hagen-Poiseuille flow. These results are consistent with a conclusion that effectiveness of heat exchange can approach unity, but may involve unwelcome trade-offs among device cost, size and throughput.

  1. CW frequency doubling of 1029 nm radiation using single pass bulk and waveguide PPLN crystals

    Czech Academy of Sciences Publication Activity Database

    Chiodo, N.; Du Burck, F.; Hrabina, Jan; Candela, Y.; Wallerand, J. P.; Acef, O.

    2013-01-01

    Roč. 311, 15 January (2013), s. 239-244 ISSN 0030-4018 R&D Projects: GA ČR GPP102/11/P820 Institutional support: RVO:68081731 Keywords : IR laser * second harmonic generation * waveguide and bulk crystals * periodically poled lithium niobate * 1029 nm wavelength Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.542, year: 2013

  2. Single-pass beam measurements for the verification of the LHC magnetic model

    CERN Document Server

    Calaga, R; Redaelli, S; Sun, Y; Tomas, R; Venturini-Delsolaro, W; Zimmermann, F

    2010-01-01

    During the 2009 LHC injection tests, the polarities and effects of specific quadrupole and higher-order magnetic circuits were investigated. A set of magnet circuits had been selected for detailed investigation based on a number of criteria. On or off-momentum difference trajectories launched via appropriate orbit correctors for varying strength settings of the magnet circuits under study - e.g. main, trim and skew quadrupoles; sextupole families and spool piece correctors; skew sextupoles, octupoles - were compared with predictions from various optics models. These comparisons allowed confirming or updating the relative polarity conventions used in the optics model and the accelerator control system, as well as verifying the correct powering and assignment of magnet families. Results from measurements in several LHC sectors are presented.

  3. Safety Evaluation for Packaging for the N Reactor/single pass reactor fuel characterization shipments

    International Nuclear Information System (INIS)

    Stevens, P.F.

    1994-01-01

    The purpose of this Safety Evaluation for Packaging (SEP) is to authorize the ChemNuclear CNS 1-13G packaging to ship samples of irradiated fuel elements from the 100 K East and 100 K West basins to the Postirradiation Testing Laboratory (PTL) in support of the spent nuclear fuel characterization effort. It also authorizes the return of the fuel element samples to the 100 K East facility using the same packaging. The CNS 1-13G cask has been-chosen to transport the fuel because it has a Certificate of Compliance (CoC) issued by the US Nuclear Regulatory Commission (NRC) for transporting irradiated oxide and metal fuel in commerce. It is capable of being loaded and offloaded underwater and may be shipped with water in the payload compartment

  4. Outdoor Storage Characteristics of Single-Pass Large Square Corn Stover Bales in Iowa

    Directory of Open Access Journals (Sweden)

    Ajay Shah

    2011-10-01

    Full Text Available Year-round operation of biorefineries can be possible only if the continuous flow of cellulosic biomass is guaranteed. If corn (Zea mays stover is the primary cellulosic biomass, it is essential to recognize that this feedstock has a short annual harvest window (≤1–2 months and therefore cost effective storage techniques that preserve feedstock quality must be identified. This study evaluated two outdoor and one indoor storage strategies for corn stover bales in Iowa. High- and low-moisture stover bales were prepared in the fall of 2009, and stored either outdoors with two different types of cover (tarp and breathable film or within a building for 3 or 9 months. Dry matter loss (DML, changes in moisture and biomass compositions (fiber and ultimate analyses were determined. DML for bales stored outdoor with tarp and breathable film covers were in the ranges of 5–11 and 14–17%, respectively. More than half of the total DML occurred early during the storage. There were measurable differences in carbon, hydrogen, nitrogen, sulfur, oxygen, cellulose, hemi-cellulose and acid detergent lignin for the different storage treatments, but the changes were small and within a narrow range. For the bale storage treatments investigated, cellulose content increased by as much as 4%s from an initial level of ~41%, hemicellulose content changed by −2 to 1% from ~34%, and acid detergent lignin contents increased by as much as 3% from an initial value of ~5%. Tarp covered bales stored the best in this study, but other methods, such as tube-wrapping, and economics need further investigation.

  5. A Novel Single Pass Authenticated Encryption Stream Cipher for Software Defined Radios

    DEFF Research Database (Denmark)

    Khajuria, Samant

    2012-01-01

    high throughput and low overhead for SDRs. The thesis is divided into two research topics. One topic is the design of a 1-pass authenticated encryption scheme that can accomplish both message secrecy and authenticity in a single cryptographic primitive. The other topic is the implementation......With the rapid growth of new wireless communication standards, a solution that is able to provide a seamless shift between existing wireless protocols and high flexibility as well as capacity is crucial. Software Defined Radio (SDR) technology offers this flexibility. It gives the possibility...

  6. Single-Pass Catalytic Conversion of Syngas into Olefins via Methanol.

    Science.gov (United States)

    Olsbye, Unni

    2016-06-20

    All together now: Combination in a single reactor of the catalysts for converting syngas into methanol and methanol into olefins was recently reported by Cheng et al. This approach considerably simplifies the catalytic conversion of natural gas. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Non-linear optics for the final focus of the single-pass-collider

    International Nuclear Information System (INIS)

    Brown, K.L.; Spencer, J.E.

    1981-02-01

    The purpose of the final focus system (FFS) is to demagnify the beam envelope in the Collider arc lattice to a size suitable for beam collisions at the interaction region. The final spot size is determined by the beam emittance, the beta function β* at the IR, the momentum spread in the beam, and the quality of the FFS optics. In particular, if the focusing system is not chromatically corrected, the momentum dispersion in the beam can lead to a substantial degradation in the quality of the final focus. The objective is to design a FFS for 50 GeV/c within approx. 100 meters having an IR spot size sigma/sub xy/ of approximately 2 μm for a beam emittance of epsilon = 3 x 10 -10 m-rad and a momentum spread of delta = +-0.5%. This requires a β/sub x,y/ equal to or less than 1 cm. This report considers the problems encountered in the design of a final focus system that will reliably provide the desired beam size for collisions

  8. One-Dimensional Modeling of Bromide Tracer and Trichloroethylene Transport Based on Laboratory Experiments in Vertical Soil Columns

    OpenAIRE

    Murch, Keri L.

    2003-01-01

    Enhanced biodegradation using carbon donor and microbial addition is being considered as a possible remediation technique for a trichloroethylene (TCE) contaminated area in Sunset, Utah, west of the source area on Hill Air Force Base. As a precursor to any in situ remediation attempts, several laboratory treatability experiments are being conducted, including the construction of microcosms and flow-through columns. Nine large-scale flow-through columns were built using site groundwater and aq...

  9. Exploring Capabilities of Electrical Capacitance Tomography Sensor and Velocity Analysis of Two-Phase R-134A Flow Through a Sudden Expansion

    Science.gov (United States)

    2017-05-01

    circles, spokes on a bicycle wheel or combinations thereof. iii. Center of Gravity - tracks a regular, roughly circular shaped object that does not...analysis showed the velocities of 71 tracked points at varying level of qualities. These velocities were analyzed and the data from these experiments...each of the video recordings, two to six features were tracked that best represented the bulk liquid flow. The velocities of these features were

  10. Pressure-driven one-step solid phase-based on-chip sample preparation on a microfabricated plastic device and integration with flow-through polymerase chain reaction (PCR).

    Science.gov (United States)

    Tran, Hong Hanh; Trinh, Kieu The Loan; Lee, Nae Yoon

    2013-10-01

    In this study, we fabricate a monolithic poly(methylmethacrylate) (PMMA) microdevice on which solid phase-based DNA preparation and flow-through polymerase chain reaction (PCR) units were functionally integrated for one-step sample preparation and amplification operated by pressure. Chelex resin, which is used as a solid support for DNA preparation, can capture denatured proteins but releases DNA, and the purified DNA can then be used as a template in a subsequent amplification process. Using the PMMA microdevices, DNA was successfully purified from both Escherichia coli and human hair sample, and the plasmid vector inserted in E. coli and the D1S80 locus in human genomic DNA were successfully amplified from on-chip purified E. coli and human hair samples. Furthermore, the integration potential of the proposed sample preparation and flow-through PCR units was successfully demonstrate on a monolithic PMMA microdevice with a seamless flow, which could pave the way for a pressure-driven, simple one-step sample preparation and amplification with greatly decreased manufacture cost and enhanced device disposability. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Analytical solutions for the temperature field in a 2D incompressible inviscid flow through a channel with walls of solid fuel

    Directory of Open Access Journals (Sweden)

    Sorin BERBENTE

    2011-12-01

    Full Text Available A gas (oxidizer flows between two parallel walls of solid fuel. A combustion is initiated: the solid fuel is vaporized and a diffusive flame occurs. The hot combustion products are submitted both to thermal diffusion and convection. Analytical solutions can be obtained both for the velocity and temperature distributions by considering an equivalent mean temperature where the density and the thermal conductivity are evaluated. The main effects of heat transfer are due to heat convection at the flame. Because the detailed mechanism of the diffusion flame is not introduced the reference chemical reaction is the combustion of premixed fuel with oxidizer in excess. In exchange the analytical solution is used to define an ideal quasi-uniform combustion that could be realized by an n adequate control. The given analytical closed solutions prove themselves flexible enough to adjust the main data of some existing experiments and to suggest new approaches to the problem.

  12. Development and Assessment of CFD Models Including a Supplemental Program Code for Analyzing Buoyancy-Driven Flows Through BWR Fuel Assemblies in SFP Complete LOCA Scenarios

    Science.gov (United States)

    Artnak, Edward Joseph, III

    This work seeks to illustrate the potential benefits afforded by implementing aspects of fluid dynamics, especially the latest computational fluid dynamics (CFD) modeling approach, through numerical experimentation and the traditional discipline of physical experimentation to improve the calibration of the severe reactor accident analysis code, MELCOR, in one of several spent fuel pool (SFP) complete loss-ofcoolant accident (LOCA) scenarios. While the scope of experimental work performed by Sandia National Laboratories (SNL) extends well beyond that which is reasonably addressed by our allotted resources and computational time in accordance with initial project allocations to complete the report, these simulated case trials produced a significant array of supplementary high-fidelity solutions and hydraulic flow-field data in support of SNL research objectives. Results contained herein show FLUENT CFD model representations of a 9x9 BWR fuel assembly in conditions corresponding to a complete loss-of-coolant accident scenario. In addition to the CFD model developments, a MATLAB based controlvolume model was constructed to independently assess the 9x9 BWR fuel assembly under similar accident scenarios. The data produced from this work show that FLUENT CFD models are capable of resolving complex flow fields within a BWR fuel assembly in the realm of buoyancy-induced mass flow rates and that characteristic hydraulic parameters from such CFD simulations (or physical experiments) are reasonably employed in corresponding constitutive correlations for developing simplified numerical models of comparable solution accuracy.

  13. Effect of Channel Geometry and Properties of a Vapor-Gas Mixture on Volume Condensation in a Flow through a Nozzle

    Science.gov (United States)

    Sidorov, A. A.; Yastrebov, A. K.

    2018-01-01

    A method of direct numerical solution of the kinetic equation for the droplet size distribution function was used for the numerical investigation of volume condensation in a supersonic vapor-gas flow. Distributions of temperature for the gas phase and droplets, degree of supersaturation, pressure, fraction of droplets by weight, the number of droplets per unit mass, and of the nucleation rate along the channel were determined. The influence of nozzle geometry, mixture composition, and temperature dependence of the mixture properties on the investigated process was evaluated. It has been found that the nozzle divergence angle determines the vapor-gas mixture expansion rate: an increase in the divergence angle enhances the temperature decrease rate and the supersaturation degree raise rate. With an increase or decrease in the partial pressure of incondensable gas, the droplet temperature approaches the gas phase temperature or the saturation temperature at the partial gas pressure, respectively. A considerable effect of the temperature dependence of the liquid surface tension and properties on gas phase parameters and the integral characteristics of condensation aerosol was revealed. However, the difference in results obtained with or without considering the temperature dependence of evaporation heat is negligible. The predictions are compared with experimental data of other investigations for two mixtures: a mixture of heavy water vapor with nitrogen (incondensable gas) or n-nonane vapor with nitrogen. The predictions agree quite well qualitatively and quantitatively with the experiment. The comparison of the predictions with numerical results from other publications obtained using the method of moments demonstrates the usefulness of the direct numerical solution method and the method of moments in a wide range of input data.

  14. Use of Interface Treatment to Reduce Emissions from Residuals in Lower Permeability Zones to Groundwater flowing Through More Permeable Zones (Invited)

    Science.gov (United States)

    Johnson, P.; Cavanagh, B.; Clifton, L.; Daniels, E.; Dahlen, P.

    2013-12-01

    Many soil and groundwater remediation technologies rely on fluid flow for contaminant extraction or reactant delivery (e.g., soil vapor extraction, pump and treat, in situ chemical oxidation, air sparging, enhanced bioremediation). Given that most unconsolidated and consolidated settings have permeability contrasts, the outcome is often preferential treatment of more permeable zones and ineffective treatment of the lower permeability zones. When this happens, post-treatment contaminant emissions from low permeability zone residuals can cause unacceptable long-term impacts to groundwater in the transmissive zones. As complete remediation of the impacted lower permeability zones may not be practicable with conventional technologies, one might explore options that lead to reduction of the contaminant emissions to acceptable levels, rather than full remediation of the lower permeability layers. This could be accomplished either by creating a sustained emission reaction/attenuation zone at the high-low permeability interface, or by creating a clean soil zone extending sufficiently far into the lower permeability layer to cause the necessary reduction in contaminant concentration gradient and diffusive emission. These options are explored in proof-of-concept laboratory-scale physical model experiments. The physical models are prepared with two layers of contrasting permeability and either dissolved matrix storage or nonaqueous phase liquid (NAPL) in the lower permeability layer. A dissolved oxidant is then delivered to the interface via flow across the higher permeability layer and changes in contaminant emissions from the low permeability zone are monitored before, during, and after oxidant delivery. The use of three oxidants (dissolved oxygen, hydrogen peroxide and sodium persulfate) for treatment of emissions from petroleum hydrocarbon residuals is examined.

  15. ACE-2 HILLCLOUD. An overview of the ACE-2 ground-based cloud experiment

    DEFF Research Database (Denmark)

    Bower, B.K.N.; Choularton, T.W.; Gallagher, M.W.

    2000-01-01

    The ACE-2 HILLCLOUD experiment was carried out on the island of Tenerife in June-July 1997 to investigate the interaction of the boundary layer aerosol with a hill cap cloud forming over a ridge to the north-east of the island. The cloud was used as a natural flow through reactor to investigate t...

  16. Information flow through the disaster circle

    DEFF Research Database (Denmark)

    Egedorf, Maren Marie; Villanueva Holm-Nielsen, Pablo

    The traditional view of the disaster circle is phase based. Disaster and development professionals recognize that the actions carried out in the various phases of the disaster management cycle are overlapping and build upon each other, having resilience as the overall goal. However information does...... not necessarily flow across the phases of the circle in an effective manner. This is particularly true for the information that crosses the disaster point of the circle. Organisations carry out assessments, surveys and baselines for various purposes, at various points of time in the disaster circle. Output......; describe how this information is gathered; analyze what information is available in previous phases of the disaster circle and to describe how that information can be shared and used in response design in an effective manner. We suggest improved information sharing between the phases of the disaster...

  17. Integrated analysis of hydrothermal flow through pretreatment

    Directory of Open Access Journals (Sweden)

    Archambault-Leger Veronique

    2012-07-01

    Full Text Available Abstract Background The impact of hydrothermal flowthrough (FT pretreatment severity on pretreatment and solubilization performance metrics was evaluated for three milled feedstocks (corn stover, bagasse, and poplar and two conversion systems (simultaneous saccharification and fermentation using yeast and fungal cellulase, and fermentation by Clostridium thermocellum. Results Compared to batch pretreatment, FT pretreatment consistently resulted in higher XMG recovery, higher removal of non-carbohydrate carbon and higher glucan solubilization by simultaneous saccharification and fermentation (SSF. XMG recovery was above 90% for FT pretreatment below 4.1 severity but decreased at higher severities, particularly for bagasse. Removal of non-carbohydrate carbon during FT pretreatment increased from 65% at low severity to 80% at high severity for corn stover, and from 40% to 70% for bagasse and poplar. Solids obtained by FT pretreatment were amenable to high conversion for all of the feedstocks and conversion systems examined. The optimal time and temperature for FT pretreatment on poplar were found to be 16 min and 210°C. At these conditions, SSF glucan conversion was about 85%, 94% of the XMG was removed, and 62% of the non carbohydrate mass was solubilized. Solubilization of FT-pretreated poplar was compared for C. thermocellum fermentation (10% inoculum, and for yeast-fungal cellulase SSF (5% inoculum, cellulase loading of 5 and 10 FPU/g glucan supplemented with β-glucosidase at 15 and 30 U/g glucan. Under the conditions tested, which featured low solids concentration, C. thermocellum fermentation achieved faster rates and more complete conversion of FT-pretreated poplar than did SSF. Compared to SSF, solubilization by C. thermocellum was 30% higher after 4 days, and was over twice as fast on ball-milled FT-pretreated poplar. Conclusions XMG removal trends were similar between feedstocks whereas glucan conversion trends were significantly different, suggesting that factors in addition to XMG removal impact amenability of glucan to enzymatic attack. Corn stover exhibited higher hydrolysis yields than bagasse or poplar, which could be due to higher removal of non-carbohydrate carbon. XMG in bagasse is more easily degraded than XMG in corn stover and poplar. Conversion of FT-pretreated substrates at low concentration was faster and more complete for C. thermocellum than for SSF.

  18. Analysis of seawater flow through optical fiber

    Science.gov (United States)

    Fernández López, Sheila; Carrera Ramírez, Jesús; Rodriguez Sinobar, Leonor; Benitez, Javier; Rossi, Riccardo; Laresse de Tetto, Antonia

    2015-04-01

    The relation between sea and coastal aquifer is very important to the human populations living in coastal areas. The interrelation involves the submarine ground water discharge of relatively fresh water to the sea and the intrusion of sea water into the aquifer, which impairs the quality of ground water. The main process in seawater intrusion is managed by fluid-density effects which control the displacement of saline water. The underlain salinity acts as the restoring force, while hydrodynamic dispersion and convection lead to a mixing and vertical displacement of the brine. Because of this, a good definition of this saltwater-freshwater interface is needed what is intimately joined to the study of the movements (velocity fields) of fresh and salt water. As it is well known, the flow of salt water studied in seawater intrusion in stationary state, is nearly null or very low. However, in the rest of cases, this flux can be very important, so it is necessary its study to a better comprehension of this process. One possible manner of carry out this analysis is through the data from optical fiber. So, to research the distribution and velocity of the fresh and saltwater in the aquifer, a fiber optic system (OF) has been installed in Argentona (Baix Maresme, Catalonia). The main objective is to obtain the distributed temperature measurements (OF-DTS) and made progress in the interpretation of the dynamic processes of water. For some applications, the optical fiber acts as a passive temperature sensor but in our case, the technique Heated Active Fiber Optic will be used. This is based on the thermal response of the ground as a heat emission source is introduced. The thermal properties of the soil, dependent variables of soil water content, will make a specific temperature distribution around the cable. From the analyzed data we will deduce the velocity field, the real objective of our problem. To simulate this phenomenon and the coupled transport and flow problem, dominant in seawater intrusion, a finite element code in C ++ language will be developed. Finally, the information obtained numerically with our code will be checked with the field information.

  19. Mathematical Modeling of Flow Through Vegetated Regions

    Science.gov (United States)

    2013-08-01

    polynomial and formulate a method to minimize the integral of the residual error. They verify their method against results from the MSC/ NASTRAN ...solved for the stable equilibria using their method with a 15th order polynomial and using MSC/ NASTRAN with 100 elements. MSC/ NASTRAN failed due to...results from Dado and Al-Sadder’s polynomial method. The MSC/ NASTRAN method failed to converge for qy < −20, but our nonlinear results match up with

  20. Characteristics of Air Flow through Windows

    DEFF Research Database (Denmark)

    Heiselberg, Per; Dam, Henrik; Sørensen, Lars C.

    This paper describes the first results of a series of laboratory investigations that is performed to characterise three different window types. The results show the air flow conditions for different ventilation strategies and temperature differences. For one of the windows values of the discharge...

  1. Characterization of Plasma Flow through Magnetic Nozzles

    Science.gov (United States)

    1990-02-01

    rovisional models are utilized to estimate the thermal transport. Filially , with regard to radiation losses over the range of parameters considered...i.nle itse-if, A amore ctmupelt physic. ldescript iti n requilre.S the Solutionl of thle etuimiionls of radiative t ralisier withidmi he flow filold, and...imbeddted ila no71le wihout q-w iug he st eady flow of phaslna. Filially , we shll (iscuss the gel eral proldeil of findtitg- II eqIilibr n wit II difie I

  2. Experimental Study of Flow Through Carotid Aneurysms

    Science.gov (United States)

    Masoomi, Faezeh; Mejia-Alvarez, Ricardo

    2017-11-01

    There is evidence that traditional endovascular techniques like coiling are not effective for treatment of wide-neck cerebral aneurysms. Flow Diverter Stents (FDS) have emerged as promising devices for treating complex aneurysms since they enable treatment of aneurysms that were considered untreatable before. Recent studies suggest a number of associated risks with FDS, including in-stent thrombosis, perianeurysmal edema, delayed hemorrhage, and perforator occlusions. Chong et al. simulated hemodynamic behavior using patient-specific data. From their study, it is possible to infer that the standard deviation of energy loss could be a good predictor for intervention success. The aim of this study is to investigate the flow in models of cerebral aneurysms before and after FDS insertion using PIV. These models will be based on actual clinical studies and will be fabricated with advanced additive manufacturing techniques. These data will then be used to explore flow parameters that could inform the likelihood of post-intervention aneurysm rupture, and help determine FDS designs that better suit any particular patient before its procedure.

  3. Simulation of viscoelastic flow through constrictions

    DEFF Research Database (Denmark)

    Szabo, Peter; Rallison, J. M.; Hinch, E. J.

    1997-01-01

    The flow of a FENE-fluid through a 4:1:4 constriction in a tube is computed by a split Lagrangian-Eulerian finite element method.In steady flow it is found that the upstream vortex grows with increasing Deborah number, while the downstream vortex diminishes and disappears.The steady pressure drop...

  4. Rapid Isotope Profiling of Speleothem by He Flow-through Laser Ablation: Insight Into Abrupt Climate Fluctuations From A new Exceptionally High Resolution Holocene \\delta18O Record From SW Ireland

    Science.gov (United States)

    Mattey, D. P.; McDermott, F.; Hawkesworth, C.

    2001-12-01

    Stable isotope analysis of carbonates at high spatial resolution is normally achieved either by microdrilling or by laser sampling, although the latter has not been widely employed, despite early promise, due to higher analytical errors particularly for oxygen isotopes. Laser ablation using a sample chamber continuously swept by He can be shown to significantly improve the accuracy and precision of carbon and oxygen isotope data, with the advantage of the rapid analysis times inherent with He flow-through technology. An automated He flow through laser-ablation system has been used to obtain continuous high resolution isotope profiles along growth axes of speleothem at a resolution of 250 microns or better. The system uses a 25W CO2 laser heat source with a continuous helium flow sample chamber on line to a conventional gas chromatograph-isotope ratio monitoring system (Micromass Optima - Isochrome). In-situ analysis of Carrara Marble yield \\delta13C and \\delta18O values reproducible to better than +/-0.1\\permil. A new high resolution isotope record comprising 1640 analyses has been obtained on a well dated 465 mm Holocene Stalagmite (CC3). For the latter part of the Holocene each analysis represents 10-22 years, but for the period prior to 5,300 years where speleothem growth rates were higher, resolution is sub-decadal. The new data accurately reproduce the first-order variation obtained by drill-sampling with \\delta18O varying from -11.65 to -0.82\\permil, but with most data varying by +/-1.75% around a mean value of -3.26\\permil. Historically cooler periods are associated with lower \\delta18O but the new profile also reveals short lived high amplitude (>3\\permil) isotope shifts. One of these events exhibits an extremely large shift of c.8\\permil over 1mm of calcite dated to between 8445 and 8400 calendar years BP. This high amplitude event is superimposed on a 350 year old episode of lowered \\delta18O that commenced at 8470 years BP but is too large to

  5. The Dominant Role of the East Siberian Sea in Driving the Oceanic Flow Through the Bering Strait—Conclusions From GRACE Ocean Mass Satellite Data and In Situ Mooring Observations Between 2002 and 2016

    Science.gov (United States)

    Peralta-Ferriz, Cecilia; Woodgate, Rebecca A.

    2017-11-01

    It is typically stated that the Pacific-to-Arctic oceanic flow through the Bering Strait (important for Arctic heat, freshwater, and nutrient budgets) is driven by local wind and a (poorly defined) far-field "pressure head" forcing, related to sea surface height differences between the Pacific and the Arctic. Using monthly, Arctic-wide, ocean bottom pressure satellite data and in situ mooring data from the Bering Strait from 2002 to 2016, we discover the spatial structure of this pressure head forcing, finding that the Bering Strait throughflow variability is dominantly driven from the Arctic, specifically by sea level change in the East Siberian Sea (ESS), in turn related to westward winds along the Arctic coasts. In the (comparatively calm) summer, this explains approximately two thirds of the Bering Strait variability. In winter, local wind variability dominates the total flow, but the pressure head term, while still correlated with the ESS-dominated sea level pattern, is now more strongly related to Bering Sea Shelf sea level variability.

  6. Electrochemical Oxidation of l-selenomethionine and Se-methylseleno-l-cysteine at a Thiol-Compound-Modified Gold Electrode: Its Application in a Flow-Through Voltammetric Sensor

    Directory of Open Access Journals (Sweden)

    Lai-Hao Wang

    2017-02-01

    Full Text Available A flow-electrolytic cell that consists of a bare gold wire or of different thiol-compound-modified gold electrodes (such as 2,4-thiazolidinedione, 2-mercapto-5-thiazoline, 2-mercaptothiazoline, l-cysteine, thioglycolic acid was designed to be used in a voltammetric detector to identify l-selenomethionine and Se-methylseleno-l-cysteine using high-performance liquid chromatography. Both l-selenomethionine and Se-methylseleno-l-cysteine are more efficiently electrochemically oxidized on a thiol/gold than on a bare gold electrode. For the DC mode, and for measurements with suitable experimental parameters, a linear concentration from 10 to 1600 ng·mL−1 was found. The limits of quantification for l-selenomethionine and Se-methylseleno-l-cysteine were below 10 ng·mL−1. The method can be applied to the quantitative determination of l-selenomethionine and Se-methylseleno-l-cysteine in commercial selenium-containing supplement products. Findings using high-performance liquid chromatography with a flow-through voltammetric detector and ultraviolet detector are comparable.

  7. On conditions and parameters important to model sensitivity for unsaturated flow through layered, fractured tuff; Results of analyses for HYDROCOIN [Hydrologic Code Intercomparison Project] Level 3 Case 2: Yucca Mountain Project

    Energy Technology Data Exchange (ETDEWEB)

    Prindle, R.W.; Hopkins, P.L.

    1990-10-01

    The Hydrologic Code Intercomparison Project (HYDROCOIN) was formed to evaluate hydrogeologic models and computer codes and their use in performance assessment for high-level radioactive-waste repositories. This report describes the results of a study for HYDROCOIN of model sensitivity for isothermal, unsaturated flow through layered, fractured tuffs. We investigated both the types of flow behavior that dominate the performance measures and the conditions and model parameters that control flow behavior. We also examined the effect of different conceptual models and modeling approaches on our understanding of system behavior. The analyses included single- and multiple-parameter variations about base cases in one-dimensional steady and transient flow and in two-dimensional steady flow. The flow behavior is complex even for the highly simplified and constrained system modeled here. The response of the performance measures is both nonlinear and nonmonotonic. System behavior is dominated by abrupt transitions from matrix to fracture flow and by lateral diversion of flow. The observed behaviors are strongly influenced by the imposed boundary conditions and model constraints. Applied flux plays a critical role in determining the flow type but interacts strongly with the composite-conductivity curves of individual hydrologic units and with the stratigraphy. One-dimensional modeling yields conservative estimates of distributions of groundwater travel time only under very limited conditions. This study demonstrates that it is wrong to equate the shortest possible water-travel path with the fastest path from the repository to the water table. 20 refs., 234 figs., 10 tabs.

  8. Experiments in a floating water bridge

    Science.gov (United States)

    Woisetschläger, Jakob; Gatterer, Karl; Fuchs, Elmar C.

    2010-01-01

    In a high-voltage direct-current experiment, a watery connection formed between two beakers filled with deionized water, giving the impression of a `floating water bridge'. Having a few millimeters diameter and up to 2.5 cm length, this watery connection reveals a number of interesting phenomena currently discussed in water science. Focusing on optical measurement techniques, the flow through the bridge was visualized and data were recorded such as flow velocity and directions, heat production, density fluctuations, pH values, drag force and mass transfer. To provide a better understanding of the basic phenomena involved the discussion references related literature.

  9. The Los Alamos POP Project: FEL oscillator experiments in the ultraviolet and beyond

    International Nuclear Information System (INIS)

    Newnam, B.E.; Warren, R.W.; Goldstein, J.C.; Schmitt, M.J.; Bender, S.C.; Carlsten, B.E.; Feldman, D.W.; O'Shea, P.G.

    1992-01-01

    The Los Alamos POP Project will include a series of proof-of-principle FEL oscillator experiments in 1992 designed to extend FEL operation into the ultraviolet (UV) and vacuum ultraviolet (VUV). With beam energy extended to 50 MeV, enhanced beam brightness with a photoinjector, and appropriate UV and VUV resonator optics, the Los Alamos FEL oscillator should have sufficient single-pass gain (20--30%) to reach below 200 nm. The first goal will be lasing at 250 nm utilizing a permanent-magnet undulator with 5-mm period or alternatively on the third harmonic with a 1-cm period. To operate at VUV wavelengths of 200 and 150 nm (third harmonic), pulsed electromagnetic microwigglers with periods of 5.7- and 4.3 mm will be employed. 23 refs

  10. Single-pass waveguide amplifiers in Er-Yb doped zinc polyphosphate glass fabricated with femtosecond laser pulses.

    Science.gov (United States)

    Fletcher, Luke B; Witcher, Jon J; Troy, Neil; Brow, Richard K; Krol, Denise M

    2012-04-01

    We have investigated the direct fabrication of subsurface waveguide amplifiers in Er-Yb zinc polyphosphate glass by utilizing the relationship between the initial glass composition and the resulting changes to the network structure after modification by fs laser pulses. Waveguides, exhibiting internal gain of 1 dB/cm at 1.53 μm when pumped with 500 mW at 976 nm, were directly fabricated using a regenerative amplified Ti:sapphire 1 kHz, 180 fs laser system. Optical properties as well as insertion losses and internal gain are reported.

  11. Single-pass waveguide amplifiers in Er-Yb doped zinc polyphosphate glass fabricated with femtosecond laser pulses

    NARCIS (Netherlands)

    Fletcher, L.B.; Witcher, J.J.; Troy, N.; Brow, R.K.; Krol, D.M.

    2012-01-01

    We have investigated the direct fabrication of subsurface waveguide amplifiers in Er-Yb zinc polyphosphate glass by utilizing the relationship between the initial glass composition and the resulting changes to the network structure after modification by fs laser pulses. Waveguides, exhibiting

  12. Integrating olive grove maintenance and energy biomass recovery with a single-pass pruning and harvesting machine

    Energy Technology Data Exchange (ETDEWEB)

    Spinelli, Raffaele; Nati, Carla; Picchi, Gianni [CNR-IVALSA, Via Madonna del Piano 10, I 50019 Sesto Fiorentino, FI (Italy); Magagnotti, Natascia [DEIAGRA, University of Bologna, Via Fanin 50, Bologna (Italy); Cantini, Claudio; Sani, Graziano [CNR-IVALSA, Azienda S. Paolina, Follonica, GR (Italy); Biocca, Marcello [CRA-ISMA, Via della Pascolare 16, Monterotondo, Roma (Italy)

    2011-02-15

    In Italy, olive tree groves may offer up to a million tonnes of dry biomass per year as pruning residue. Searching for a cost-effective way to tap this potential, the authors tested a new machine, capable of recovering pruning residue at the same time as pruning. The pre-commercial prototype was tested on four different plots and compared to a simpler tractor-base mechanical pruning unit. The authors conducted detailed time-studies in order to determine machine productivity and residue recovery cost. The integrated machine can treat between 0.2 and 0.6 ha h{sup -1}, producing between 0.33 and 1.03 tonnes of fresh residue hour{sup -1}. Its integrated residue recovery function does not slow the pruning, which actually proceeds faster than with the tractor-base unit, due to the more efficient multiple-disc cutting bar. The marginal cost of residue recovery hovers around 40-45 EUR fresh tonne{sup -1}. However, the new machine must not be considered just as a biomass harvester, but rather as a mechanical pruning unit with an integrated biomass recovery function. Its main benefit derives from the capacity of performing a very effective mechanical pruning, and the residue recovery function is a secondary benefit yet unavailable on standard pruning machines. Its deployment must be seen in the context of a general effort to modernize olive grove management and to develop an integrated biomass production system, rather than as a further attempt to build a specialised biomass supply chain. (author)

  13. Spin motion determination of the Envisat satellite through laser ranging measurements from a single pass measured by a single station

    Science.gov (United States)

    Pittet, Jean-Noël; Šilha, Jiří; Schildknecht, Thomas

    2018-02-01

    The Satellite Laser Ranging (SLR) technology is used to accurately determine the position of space objects equipped with so-called retro-reflectors or retro-reflector arrays (RRA). This type of measurement allows to measure the range to the spacecraft with high precision, which leads to determination of very accurate orbits for these targets. Non-active spacecraft, which are not attitude controlled any longer, tend to start to spin or tumble under influence of the external and internal torques and forces. If the return signal is measured for a non-spherical non-active rotating object, the signal in the range residuals with respect to the reference orbit is more complex. For rotating objects the return signal shows an oscillating pattern or patterns caused by the RRA moving around the satellite's centre of mass. This behaviour is projected onto the radial component measured by the SLR. In our work, we demonstrate how the SLR ranging technique from one sensor to a satellite equipped with a RRA can be used to precisely determine its spin motion during one passage. Multiple SLR measurements of one target over time allow to accurately monitor spin motion changes which can be further used for attitude predictions. We show our solutions of the spin motion determined for the non-active ESA satellite Envisat obtained from measurements acquired during years 2013-2015 by the Zimmerwald SLR station, Switzerland. All the necessary parameters are defined for our own so-called point-like model which describes the motion of a point in space around the satellite centre of mass.

  14. Method of analysis of a selected group of pyrethroids in soil samples using off-line flow-through extraction and on-column direct large-volume injection in reversed phase high performance liquid chromatography.

    Science.gov (United States)

    Chalányová, Mária; Paulechová, Martina; Hutta, Milan

    2006-09-01

    An analytical method using flow-through extraction of a soil sample filled in a short HPLC column with methanol or methanol-water mixtures and large-volume injection in RP-HPLC has been developed for the simultaneous determination of residues of three pyrethroids--kadethrin, cypermethrin, and permethrin--from soil samples. The developed RP-HPLC method enables separation of four diastereoisomers of cypermethrin into three peaks and resolution of two diastereoisomers of permethrin. The UV photometric detection limits of direct on-column large-volume injection of 1.00 mL of extract were 30 ng/mL of kadethrin, 37 ng/mL of total content of cypermethrin, and 65 ng/mL of trans-permethrin, which corresponds to a pyrethroid soil content of around 0.3 mg/kg. Effects of extractant flow rate and optimal extractant volume on the percentage recovery of pyrethroids from Slovak soil samples were studied. Recovery studies were performed at 0.5- 5.0 microg/g fortification level of kadethrin and 1.0-2.5 microg/g fortification level of cypermethrin and permethrin in a soil sample. Recoveries ranged from 83 to 90% for kadethrin, from 87 to 94% for total cypermethrin, and from 85 to 98% for trans-permethrin. This work comprises a basic study aimed at elaboration of an RP-HPLC method of direct analysis of pyrethroids in a soil matrix at low concentration levels achieved by a "solid sample injection" in HPLC--on-line interfacing of analyte extraction, extract clean-up, and analysis.

  15. The Experiment of Drying Process of the Fibrous Material

    Directory of Open Access Journals (Sweden)

    Jiří RASZKA

    2015-06-01

    Full Text Available The article describes the experiment of water evaporation from fibrous material (cotton. The material is placed in the tube and hot air flows through (process of drying. Temperature of air is measured by thermocouple. The textile represents porous medium with certain amount of water (wet textile. Porous layer makes pressure drop when airflow starts. Properties of air (temperature, relative humidity change during evaporation process. Values of pressure drop, temperature and humidity measured during experiment are used for set up of boundary condition, porous layer and evaporation model in Ansys Fluent 13.

  16. Clouds and the Earth's Radiant Energy System (CERES) experiment

    Science.gov (United States)

    Cooper, John E.; Barkstrom, Bruce R.; Kopia, Leonard P.

    1992-01-01

    The Clouds and the Earth's Radiant Energy System (CERES) experiment will play a major role in NASA's planned multi-instrument multi-satellite Earth Observing System (EOS) program to observe and study the total Earth System on a global scale. The CERES experiment will provide EOS with a consistent data base of accurately known fields of radiation and of clouds; and will investigate the important question of the impact of clouds upon the radiative energy flow through the earth-atmosphere system. The CERES instruments will be an improved version of the Earth Radiation Budget Experiment (ERBE) broadband scanning radiometer instruments flown by NASA in the 1980s. This paper describes the CERES experiment approach and the current CERES instrument design status.

  17. Eelgrass detritus as a food source for the sea cucumber Apostichopus japonicus Selenka (Echinidermata: Holothuroidea in coastal waters of North China: an experimental study in flow-through systems.

    Directory of Open Access Journals (Sweden)

    Xujia Liu

    Full Text Available Eelgrass ecosystems have a wide variety of ecological functions in which living tissues and detritus may be a food source for many marine animals. In this study, we conducted a laboratory simulating experiment to understand the trophic relationship between the eelgrass Zostera marina L and the sea cucumber Apostichopus japonicus. A mixture of decaying eelgrass debris and seafloor surface muddy sediments was used as food to feed A. japonicus, and then specific growth rates (SGR and fecal production rates (FPR were measured. According to the proportion of eelgrass debris, we designed five treatment diets, i.e., ES0, ES10, ES20, ES40, and ES100, with eelgrass debris accounting for 0%, 10%, 20%, 40%, and 100% in dry weight, respectively. Results showed that diet composition had a great influence on the growth of A. japonicus. Sea cucumbers could use decaying eelgrass debris as their food source; and when the organic content of a mixture of eelgrass debris and sediment was 19.6% (ES40, a relatively high SGR (1.54%·d(-1 and FPR (1.31 g·ind.(-1 d(-1 of A. japonicus were obtained. It is suggested that eelgrass beds can not only provide habitat for the sea cucumber A. japonicus but can also provide an indirect food source for the deposit feeder. This means that the restoration and reconstruction of eelgrass beds, especially in coastal waters of China, would be a potential and effective measure for sea-cucumber fisheries, in respect to both resource restoration and aquaculture of this valuable species.

  18. Eelgrass detritus as a food source for the sea cucumber Apostichopus japonicus Selenka (Echinidermata: Holothuroidea) in coastal waters of North China: an experimental study in flow-through systems.

    Science.gov (United States)

    Liu, Xujia; Zhou, Yi; Yang, Hongsheng; Ru, Shaoguo

    2013-01-01

    Eelgrass ecosystems have a wide variety of ecological functions in which living tissues and detritus may be a food source for many marine animals. In this study, we conducted a laboratory simulating experiment to understand the trophic relationship between the eelgrass Zostera marina L and the sea cucumber Apostichopus japonicus. A mixture of decaying eelgrass debris and seafloor surface muddy sediments was used as food to feed A. japonicus, and then specific growth rates (SGR) and fecal production rates (FPR) were measured. According to the proportion of eelgrass debris, we designed five treatment diets, i.e., ES0, ES10, ES20, ES40, and ES100, with eelgrass debris accounting for 0%, 10%, 20%, 40%, and 100% in dry weight, respectively. Results showed that diet composition had a great influence on the growth of A. japonicus. Sea cucumbers could use decaying eelgrass debris as their food source; and when the organic content of a mixture of eelgrass debris and sediment was 19.6% (ES40), a relatively high SGR (1.54%·d(-1)) and FPR (1.31 g·ind.(-1) d(-1)) of A. japonicus were obtained. It is suggested that eelgrass beds can not only provide habitat for the sea cucumber A. japonicus but can also provide an indirect food source for the deposit feeder. This means that the restoration and reconstruction of eelgrass beds, especially in coastal waters of China, would be a potential and effective measure for sea-cucumber fisheries, in respect to both resource restoration and aquaculture of this valuable species.

  19. Customer experience

    OpenAIRE

    Koperdáková, Zuzana

    2016-01-01

    Bachelor thesis deals with the theme of customer experience and terms related to this topic. The thesis consists of three parts. The first part explains the terms generally, as the experience or customer loyalty. The second part is dedicated to medotology used for Customer Experience Management. In the third part is described application of Customer Experience Management in practice, particularly in the context Touch Point Analyses in GE Money Bank.

  20. OPERA experiment

    International Nuclear Information System (INIS)

    Komatsu, M.

    2003-01-01

    OPERA is an accelerator experiment designed to explore Super-Kamiokande suggested ν μ ↔ν τ oscillation region in CNGS beam from CERN to LNGS. The key technique in OPERA is modern emulsion read out which applied to CHORUS and DONUT experiments. ECC technique which used in DONUT and OPERA has good modularity to enlarge apparatus for future Neutrino Factory experiments

  1. GOTCHA experience report: three-dimensional SAR imaging with complete circular apertures

    Science.gov (United States)

    Ertin, Emre; Austin, Christian D.; Sharma, Samir; Moses, Randolph L.; Potter, Lee C.

    2007-04-01

    We study circular synthetic aperture radar (CSAR) systems collecting radar backscatter measurements over a complete circular aperture of 360 degrees. This study is motivated by the GOTCHA CSAR data collection experiment conducted by the Air Force Research Laboratory (AFRL). Circular SAR provides wide-angle information about the anisotropic reflectivity of the scattering centers in the scene, and also provides three dimensional information about the location of the scattering centers due to a non planar collection geometry. Three dimensional imaging results with single pass circular SAR data reveals that the 3D resolution of the system is poor due to the limited persistence of the reflectors in the scene. We present results on polarimetric processing of CSAR data and illustrate reasoning of three dimensional shape from multi-view layover using prior information about target scattering mechanisms. Next, we discuss processing of multipass (CSAR) data and present volumetric imaging results with IFSAR and three dimensional backprojection techniques on the GOTCHA data set. We observe that the volumetric imaging with GOTCHA data is degraded by aliasing and high sidelobes due to nonlinear flightpaths and sparse and unequal sampling in elevation. We conclude with a model based technique that resolves target features and enhances the volumetric imagery by extrapolating the phase history data using the estimated model.

  2. Elastic Instabilities in Polymer-Solution Flow Through Porous Media

    NARCIS (Netherlands)

    Kawale, D.

    2017-01-01

    Crude oil has been an important source of energy for several decades now. Upon discovery of a crude oil reservoir until its abandonment, typically the oil recovery process can be classified in three stages. The primary and the secondary stage involve utilizing and maintaining reservoir pressure to

  3. A continuum model for meltwater flow through compacting snow

    Science.gov (United States)

    Meyer, Colin R.; Hewitt, Ian J.

    2017-12-01

    Meltwater is produced on the surface of glaciers and ice sheets when the seasonal energy forcing warms the snow to its melting temperature. This meltwater percolates into the snow and subsequently runs off laterally in streams, is stored as liquid water, or refreezes, thus warming the subsurface through the release of latent heat. We present a continuum model for the percolation process that includes heat conduction, meltwater percolation and refreezing, as well as mechanical compaction. The model is forced by surface mass and energy balances, and the percolation process is described using Darcy's law, allowing for both partially and fully saturated pore space. Water is allowed to run off from the surface if the snow is fully saturated. The model outputs include the temperature, density, and water-content profiles and the surface runoff and water storage. We compare the propagation of freezing fronts that occur in the model to observations from the Greenland Ice Sheet. We show that the model applies to both accumulation and ablation areas and allows for a transition between the two as the surface energy forcing varies. The largest average firn temperatures occur at intermediate values of the surface forcing when perennial water storage is predicted.

  4. simulation of vertical water flow through vadose zone

    African Journals Online (AJOL)

    HOD

    hundreds (100) meters to water table as common in arid regions [1]. The vadose zone is not always considered .... software system was developed by the International. Hydrological Program (UNESCO) [13] to raise ... obtained from samples collected from various locations in the NDA permanent site. Simulation parameters ( ...

  5. Experimental and numerical investigations of flow through free ...

    African Journals Online (AJOL)

    2010-06-05

    Jun 5, 2010 ... tional fluid dynamics (CFD) Fluent package (ANSYS, 2006) to numerically simulate the hydraulic performance and flow struc- ture throughout the double baffled gate distributors. The final stage involved the analysis of the experimental and simulated data and the production of a user-friendly spreadsheet to ...

  6. Immersed boundary simulation of flow through arterial junctions

    Indian Academy of Sciences (India)

    Instabilities in the flow structures near the junction and the resulting changes in the downstream pulsation frequency were observed. These changes account for the physiological heart defects that arise from the poorly working valve (due to blockage),giving rise to chest pain and breathing instability, and can potentially be ...

  7. Water flow through the polypropylene-based geotextiles.

    CSIR Research Space (South Africa)

    Patanaik, A

    2008-06-01

    Full Text Available the Polypropylene-Based Geotextiles Asis Patanaik,1,2 Rajesh D. Anandjiwala1,2 1CSIR Materials Science and Manufacturing, Fibers and Textiles Competence Area, Port Elizabeth 6000, South Africa 2Department of Textile Science, Faculty of Science, Nelson Mandela...) through the nonwoven fabrics plays an important role in many applications such as medical and hygiene, fil- tration, composite manufacturing, etc. Nonwoven geotextiles are fibrous structures capable of doing more than one functions simultaneously, i...

  8. Reverse flow through a large scale multichannel nozzle

    International Nuclear Information System (INIS)

    Duignan, M.R.; Nash, C.A.

    1992-01-01

    A database was developed for the flow of water through a scaled nozzle of a Savannah River Site reactor inlet plenum. The water flow in the nozzle was such that it ranged from stratified to water solid conditions. Data on the entry of air into the nozzle and plenum as a function of water flow are of interest in loss-of-coolant studies. The scaled nozzle was 44 cm long, had an entrance diameter of 95 mm, an exit opening of 58 mm x 356 mm, and an exit hydraulic diameter approximately equal to that of the inlet. Within the nozzle were three flow-straightening vanes which divided the flow path into four channels. All data were taken at steady-state and isothermal (300 K ± 1.5 K) conditions. During the reverse flow of water through the nozzle the point at which air begins to enter was predicted within 90% by a critical weir-flow calculation. The point of air entry into the plenum itself was found to be a function of flow conditions

  9. Simple methods for predicting gas leakage flows through cracks

    International Nuclear Information System (INIS)

    Ewing, D.J.F.

    1989-01-01

    This report presents closed-form approximate analytical formulae with which the flow rate out of a through-wall crack can be estimated. The crack is idealised as a rough, tapering, wedgeshaped channel and the fluid is idealised as an isothermal or polytropically-expanding perfect gas. In practice, uncertainties about the wall friction factor dominate over uncertainties caused by the fluid-dynamics simplifications. The formulae take account of crack taper and for outwardly-diverging cracks they predict flows within 12% of mathematically more accurate one-dimensional numerical models. Upper and lower estimates of wall friction are discussed. (author)

  10. Meltater Flow Through Snow from Plot to Baisn Scale

    National Research Council Canada - National Science Library

    Williams, Mark

    2000-01-01

    ... research instrumentation award. Near-infrared photographs of melting snow were analyzed using a moving windows procedure that can be used to define the correlation lengths in the snow reflectance surface...

  11. Pressure independence of granular flow through an aperture.

    Science.gov (United States)

    Aguirre, M A; Grande, J G; Calvo, A; Pugnaloni, L A; Géminard, J-C

    2010-06-11

    We experimentally demonstrate that the flow rate of granular material through an aperture is controlled by the exit velocity imposed on the particles and not by the pressure at the base, contrary to what is often assumed in previous work. This result is achieved by studying the discharge process of a dense packing of monosized disks through an orifice. The flow is driven by a conveyor belt. This two-dimensional horizontal setup allows us to independently control the velocity at which the disks escape the horizontal silo and the pressure in the vicinity of the aperture. The flow rate is found to be proportional to the belt velocity, independent of the amount of disks in the container and, thus, independent of the pressure in the outlet region. In addition, this specific configuration makes it possible to get information on the system dynamics from a single image of the disks that rest on the conveyor belt after the discharge.

  12. Analytical effective tensor for flow-through composites

    Science.gov (United States)

    Sviercoski, Rosangela De Fatima [Los Alamos, NM

    2012-06-19

    A machine, method and computer-usable medium for modeling an average flow of a substance through a composite material. Such a modeling includes an analytical calculation of an effective tensor K.sup.a suitable for use with a variety of media. The analytical calculation corresponds to an approximation to the tensor K, and follows by first computing the diagonal values, and then identifying symmetries of the heterogeneity distribution. Additional calculations include determining the center of mass of the heterogeneous cell and its angle according to a defined Cartesian system, and utilizing this angle into a rotation formula to compute the off-diagonal values and determining its sign.

  13. Electrochemical Oxidation of Phenol using a Flow-through Micro ...

    African Journals Online (AJOL)

    The electrochemical oxidation of phenol to benzoquinone followed by the reduction to hydroquinone and catechol was demonstrated by constructing a three-dimensional porous micro-flow cell from lead dioxideand lead. The electrodes were made by using the principles of curing and formation of lead oxide material that ...

  14. Two-dimensional steady unsaturated flow through embedded elliptical layers

    Science.gov (United States)

    Bakker, Mark; Nieber, John L.

    2004-12-01

    New analytic element solutions are presented for unsaturated, two-dimensional steady flow in vertical planes that include nonoverlapping impermeable elliptical layers and elliptical inhomogeneities. The hydraulic conductivity, which is represented by an exponential function of the pressure head, differs between the inside and outside of an elliptical inhomogeneity; both the saturated hydraulic conductivity and water retention parameters are allowed to differ between the inside and outside. The Richards equation is transformed, through the Kirchhoff transformation and a second standard transformation, into the modified Helmholtz equation. Analytic element solutions are obtained through separation of variables in elliptical coordinates. The resulting equations for the Kirchhoff potential consist of infinite sums of products of exponentials and modified Mathieu functions. In practical applications the series are truncated but still fulfill the differential equation exactly; boundary conditions are met approximately but up to machine accuracy, provided that enough terms are used. The pressure head, saturation, and flow may be computed analytically at any point in the vadose zone. Examples are given of the shadowing effect of an impermeable elliptical layer in a uniform flow field and funnel-type flow between two elliptical inhomogeneities. The presented solutions may be applied to study transport processes in vadose zones containing many impermeable elliptical layers or elliptical inhomogeneities.

  15. Radionuclide transport by groundwater flow through the geosphere: current status

    International Nuclear Information System (INIS)

    Lever, D.A.

    1989-02-01

    The geosphere is an important barrier retaining radionuclides that have been released from the near field of a waste repository and retarding their return to Man. The assessment models that are used in the current Nirex assessments to describe the groundwater flow in the vicinity of the repository and the transport of radionuclides by the groundwater are summarized, and their data requirements are set out. The Nirex research programme is designed to provide improved and additional data for these models, to deepen the understanding of the important processes and to develop improved models to describe them. This document outlines the status of the assessment models and associated research programme in the spring of 1988. The programme complements existing knowledge in this field. Key areas are measurements of the physical properties of rocks, field and modelling studies of fractured rocks, measurements of sorption onto geological materials, investigation of the possible importance of colloid transport and saline interfaces, transport of naturally occurring elements over geological time-scales in natural geochemical systems, and participation in an international model validation exercise. (author)

  16. Create a Better Flow through Sequencing Resident Assistant Training

    Science.gov (United States)

    Whitney, Rich; Early, Sherry; Whisler, Travis

    2016-01-01

    Resident assistant training happens every year for the approximate 10,000 RAs who work on campuses across the country. These training programs can include classes, pre-service summer weeks, and ongoing training throughout the year. Following educational and training models such as CAS, assessment, Bloom's taxonomy, adventure programming, and…

  17. THE ENHANCEMENT OF BUSINESS INFORMATION FLOW THROUGH E-INVOICING

    Directory of Open Access Journals (Sweden)

    PĂCURARI DOINA

    2014-05-01

    Full Text Available E-invoicing represents a solution for making the business management more efficient and for protecting the environment. The technologies available at present allow us to solve the potential problems related to the authorization of the invoices within the company, as well as to deal more conveniently with other documents issued in electronic formats. Moreover, the electronic invoicing and the archiving of the documents can be outsourced, as the solutions under cloud are very promising. Our paper approaches the advantages of e-invoicing, the recommendations of the European Commission with respect to the use of the electronic invoice and their implementation in the EU member states legislation, with a strong focus on the case of Romania.

  18. Modelling flow through unsaturated zones: Sensitivity to unsaturated ...

    Indian Academy of Sciences (India)

    A numerical model to simulate moisture flow through unsaturated zones is developed using the finite element method, and is validated by comparing the model results with those available in the literature. The sensitivities of different processes such as gravity drainage and infiltration to the variations in the unsaturated soil ...

  19. Microcomputer-Assisted Flow-Through ASV System.

    Science.gov (United States)

    1979-09-01

    FILL BUFFER VI BLANKS 001E A7 00 A BLANKS STAA X 0020 08 INX 0021 BC 0000 A CPX TADRU 0024 26 F8 001E BNE BLANKS 0026 Cl 05 A CMPB #5 CALLED FROM K...A4,130,$99,$92,$03,$ F8 ,$00 0001 79 A 0002 A4 A 0003 33 A 0004 9a A 0005 92 A 0006 03 A 0007 F8 A 0008 00 A 0009 19 A 0000 DSCT 0000 07DO A DATA RMB 2000...FXVAL AND LPTNO,LXVAL *RETURN I-TRUE 0-FALSE IN ACCA *T VALUE ON LINE IS LEFT IN Y 0390 FE 0033 D AELINE LDX FPTNO /GET Ti 0393 09 DIX 1ST Y VALUE 0394

  20. Study of two-phase critical flows through small breaches

    International Nuclear Information System (INIS)

    Chalant, Jean Marc; Willocx, Marc

    1981-06-01

    The first part of this academic document reports experimental works performed for the design and realisation of an installation (DALIDA) aimed at the study of critical flow rates through a hole. As this experimental study had to be given up for practical reasons, the authors focused on the theoretical study of this phenomenon. Based on a model proposed by Lackme for critical flows in long tubes, the authors developed a model which could be applied to the case of a tube ended by a hole. Numerical results have been obtained which are still to be experimentally confirmed [fr