WorldWideScience

Sample records for single-pass flow apparatus

  1. Uranium Release from Acidic Weathered Hanford Sediments: Single-Pass Flow-Through and Column Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Guohui [Pacific Northwest National Laboratory, Richland, Washington 99354, United States; Um, Wooyong [Pacific Northwest National Laboratory, Richland, Washington 99354, United States; Pohang University of Science and Technology (POSTECH), Pohang, South Korea; Wang, Zheming [Pacific Northwest National Laboratory, Richland, Washington 99354, United States; Reinoso-Maset, Estela [Sierra; Washton, Nancy M. [Pacific Northwest National Laboratory, Richland, Washington 99354, United States; Mueller, Karl T. [Pacific Northwest National Laboratory, Richland, Washington 99354, United States; Perdrial, Nicolas [Department; Department; O’Day, Peggy A. [Sierra; Chorover, Jon [Department

    2017-09-21

    The reaction of acidic radioactive waste with sediments can induce mineral transformation reactions that, in turn, control contaminant fate. Here, sediment weathering by synthetic uranium-containing acid solutions was investigated using bench-scale experiments to simulate waste disposal conditions at Hanford’s cribs, USA. During acid weathering, the presence of phosphate exerted a strong influence over uranium mineralogy and a rapidly precipitated, crystalline uranium phosphate phase (meta-ankoleite [K(UO2)(PO4)·3H2O]) was identified using spectroscopic and diffraction-based techniques. In phosphate-free system, uranium oxyhydroxide minerals such as K-compreignacite [K2(UO2)6O4(OH)6·7H2O] were formed. Single-pass flow-through (SPFT) and column leaching experiments using synthetic Hanford pore water showed that uranium precipitated as meta-ankoleite during acid weathering was strongly retained in the sediments, with an average release rate of 2.67E-12 mol g-1 s-1. In the absence of phosphate, uranium release was controlled by dissolution of uranium oxyhydroxide (compreignacite-type) mineral with a release rate of 1.05-2.42E-10 mol g-1 s-1. The uranium mineralogy and release rates determined for both systems in this study support the development of accurate U-release models for prediction of contaminant transport. These results suggest that phosphate minerals may be a good candidate for uranium remediation approaches at contaminated sites.

  2. Evaluation of regional pulmonary blood flow in mitral valvular heart disease using single-pass radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Chang-Soon Koh; Byung Tae Kim; Myung Chul Lee; Bo Yeon Cho

    1982-01-01

    Pulmonary hypertension in mitral valvular cardiac disease has been evaluated in 122 patients by a modified upper lung/lower count ratio using single-pass radionuclide angiocardiography. The mean upper lung/lower lung radio correlates well with pulmonary artery mean (r=0.483) and wedge pressure (r=0.804). After correction surgery of the cardiac valve, the ratio decreases and returns to normal range in patients judged clinically to have good surgical benifit. This modified method using single-pass technique provides additional simple, reproducible and nontraumatic results of regional pulmonary blood flow and appears to be correlated with the degree of pulmonary hypertension in mitral heart disease

  3. FY2016 ILAW Glass Corrosion Testing with the Single-Pass Flow-Through Method

    Energy Technology Data Exchange (ETDEWEB)

    Neeway, James J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Asmussen, Robert M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Parruzot, Benjamin PG [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Cordova, Elsa [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Williams, Benjamin D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Leavy, Ian I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Stephenson, John R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); McElroy, Erin M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-04-21

    The inventory of immobilized low-activity waste (ILAW) produced at the Hanford Tank Waste Treatment and Immobilization Plant (WTP) will be disposed of at the near-surface, on-site Integrated Disposal Facility (IDF). When groundwater comes into contact with the waste form, the glass will corrode and radionuclides will be released into the near-field environment. Because the release of the radionuclides is dependent on the dissolution rate of the glass, it is important that the performance assessment (PA) model accounts for the dissolution rate of the glass as a function of various chemical conditions. To accomplish this, an IDF PA model based on Transition State Theory (TST) can be employed. The model is able to account for changes in temperature, exposed surface area, and pH of the contacting solution as well as the effect of silicon concentrations in solution, specifically the activity of orthosilicic acid (H4SiO4), whose concentration is directly linked to the glass dissolution rate. In addition, the IDF PA model accounts for the alkali-ion exchange process as sodium is leached from the glass and into solution. The effect of temperature, pH, H4SiO4 activity, and the rate of ion-exchange can be parameterized and implemented directly into the PA rate law model. The rate law parameters are derived from laboratory tests with the single-pass flow-through (SPFT) method. To date, rate law parameters have been determined for seven ILAW glass compositions, thus additional rate law parameters on a wider range of compositions will supplement the existing body of data for PA maintenance activities. The data provided in this report can be used by ILAW glass scientists to further the understanding of ILAW glass behavior, by IDF PA modelers to use the rate law parameters in PA modeling efforts, and by Department of Energy (DOE) contractors and decision makers as they assess the IDF PA program.

  4. Standard practice for measurement of the glass dissolution rate using the single-pass flow-through test method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This practice describes a single-pass flow-through (SPFT) test method that can be used to measure the dissolution rate of a homogeneous silicate glass, including nuclear waste glasses, in various test solutions at temperatures less than 100°C. Tests may be conducted under conditions in which the effects from dissolved species on the dissolution rate are minimized to measure the forward dissolution rate at specific values of temperature and pH, or to measure the dependence of the dissolution rate on the concentrations of various solute species. 1.2 Tests are conducted by pumping solutions in either a continuous or pulsed flow mode through a reaction cell that contains the test specimen. Tests must be conducted at several solution flow rates to evaluate the effect of the flow rate on the glass dissolution rate. 1.3 This practice excludes static test methods in which flow is simulated by manually removing solution from the reaction cell and replacing it with fresh solution. 1.4 Tests may be conducted wit...

  5. Single Pass Albumin Dialysis-A Dose-Finding Study to Define Optimal Albumin Concentration and Dialysate Flow.

    Science.gov (United States)

    Schmuck, Rosa Bianca; Nawrot, Gesa-Henrike; Fikatas, Panagiotis; Reutzel-Selke, Anja; Pratschke, Johann; Sauer, Igor Maximilian

    2017-02-01

    Several artificial liver support concepts have been evaluated both in vitro and clinically. Single pass albumin dialysis (SPAD) has shown to be one of the most simple approaches for removing albumin-bound toxins and water-soluble substances. Being faced with acute liver failure (ALF) in everyday practice encouraged our attempt to define the optimal conditions for SPAD more precisely in a standardized experimental setup. Albumin concentration was adjusted to either 1%, 2%, 3%, or 4%, while the flow rate of the dialysate was kept constant at a speed of 700 mL/h. The flow rate of the dialysate was altered between 350, 500, 700, and 1000 mL/h, whereas the albumin concentration was continuously kept at 3%. This study revealed that the detoxification of albumin-bound substances could be improved by increasing the concentration of albumin in the dialysate with an optimum at 3%. A further increase of the albumin concentration to 4% did not lead to a significant increase in detoxification. Furthermore, we observed a gradual increase of the detoxification efficiency for albumin-bound substances, from 350 mL/h to 700 mL/h (for bilirubin) or 1000 mL/h (for bile acids) of dialysate flow. Water-soluble toxins (ammonia, creatinine, urea, uric acid) were removed almost completely, regardless of albumin concentration or flow rate. In conclusion, this study confirmed that SPAD is effective in eliminating albumin-bound as well as water-soluble toxins using a simulation of ALF. Furthermore, this project was successful in evaluating the most effective combination of albumin concentration (3%) and dialysate flow (700 mL/h-1000 mL/h) in SPAD for the first time. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  6. Evaluation of the single-pass flow-through test to support a low-activity waste specification

    International Nuclear Information System (INIS)

    McGrail, B.P.; Peeler, D.K.

    1995-09-01

    A series of single-pass flow-through (SPFT) tests was performed on five reference low-activity waste glasses and a reference glass from the National Institute of Standards and Technology to support a product specification for low-activity waste (LAW) forms. The results showed that the SPFT test provides a means to quantitatively distinguish among LAW glass forms in terms of their forward reaction rate at a given temperature and solution pH. Two of the test glasses were also subjected to SPFT testing at Argonne National Laboratory (ANL). Forward reaction rate constants calculated from the ANL test data were 100 to over 1,000 times larger than the values obtained from the SPFT tests conducted at PNL. An analysis of the ANL results showed that they were inconsistent with independent measurements done on glasses of similar composition, the known pH-dependence of the forward rate, and with the results from low surface-area-to-volume, short duration product consistency tests. Because the data set obtained from the SPFT tests done at PNL was consistent with each of these same factors, a detailed examination of the test procedures used at both laboratories was performed to determine the cause(s) of the discrepancy. The omission of background subtraction in the data analysis procedure and the short-duration (on the order of hours) of the ANL tests are factors that may have significantly affected the calculated rates

  7. Regional brain blood flow in mouse: quantitative measurement using a single-pass radio-tracer method and a mathematical algorithm.

    Science.gov (United States)

    Xu, K; Radhakrishnan, K; Serhal, A; Allen, F; Lamanna, J C; Puchowicz, M A

    2011-01-01

    We have developed a reliable experimental method for measuring local regional cerebral blood flows in anesthetized mice. This method is an extension of the well-established single-pass dual-label indicator method for simultaneously measuring blood flow and glucose influx in rat brains. C57BL6J mice (n = 10) were anesthetized and regional blood flows (ml/min/g) were measured using the radio-tracer method. To test the sensitivity of this method we used a mathematical algorithm to predict the blood flows and compared the two sets of results.Measured regional blood flows between 0.7 and 1.7 ml/min/g were similar to those we have previously reported in the rat. The predicted blood flows using an assumed linearly increasing arterial tracer concentration-versus-time profile (that is, a ramp) were similar to the values measured in the physiological experiments (R(2) 0.99; slope 0.91). Thus,measurements of local regional cerebral blood flow in anesthetized mice using a single-pass radio-tracer method appear to be reliable.

  8. Characterization of the solid, airborne materials created when UF6 reacts with moist air flowing in single-pass mode

    International Nuclear Information System (INIS)

    Pickrell, P.W.

    1985-10-01

    A series of experiments has been performed in which UF 6 was released into flowing air in order to characterize the solid particulate material produced under non-static conditions. In two of the experiments, the aerosol was allowed to stagnate in a static chamber after release and examined further but in the other experiments characterization was done only on material collected a few seconds after release. Transmission electron microscopy and mass measurement by cascaded impactor were used to characterize the aerosol particles which were usually single spheroids with little agglomeration in evidence. The goal of the work is to determine the chemistry and physics of the UF 6 -atmospheric moisture reaction under a variety of conditions so that information about resulting species and product morphologies is available for containment and removal (knockdown) studies as well as for dispersion plume modeling and toxicology studies. This report completes the milestone for reporting the information obtained from releases of UF 6 into flowing rather than static air. 26 figs., 3 tabs

  9. Apparatus for measuring fluid flow

    Science.gov (United States)

    Smith, J.E.; Thomas, D.G.

    Flow measuring apparatus includes a support loop having strain gages mounted thereon and a drag means which is attached to one end of the support loop and which bends the sides of the support loop and induces strains in the strain gages when a flow stream impacts thereon.

  10. EMISAR single pass topographic SAR interferometer modes

    DEFF Research Database (Denmark)

    Madsen, Søren Nørvang; Skou, Niels; Woelders, Kim

    1996-01-01

    The Danish Center for Remote Sensing (DCRS) has augmented its dual-frequency polarimetric synthetic aperture radar system (EMISAR) with single pass across-track interferometric (XTI) modes. This paper describes the system configuration, specifications and the operating modes. Analysis of data acq...

  11. Apparatus for monitoring two-phase flow

    Science.gov (United States)

    Sheppard, John D.; Tong, Long S.

    1977-03-01

    A method and apparatus for monitoring two-phase flow is provided that is particularly related to the monitoring of transient two-phase (liquid-vapor) flow rates such as may occur during a pressurized water reactor core blow-down. The present invention essentially comprises the use of flanged wire screens or similar devices, such as perforated plates, to produce certain desirable effects in the flow regime for monitoring purposes. One desirable effect is a measurable and reproducible pressure drop across the screen. The pressure drop can be characterized for various known flow rates and then used to monitor nonhomogeneous flow regimes. Another useful effect of the use of screens or plates in nonhomogeneous flow is that such apparatus tends to create a uniformly dispersed flow regime in the immediate downstream vicinity. This is a desirable effect because it usually increases the accuracy of flow rate measurements determined by conventional methods.

  12. Apparatus for monitoring two-phase flow

    International Nuclear Information System (INIS)

    Sheppard, J.D.; Tong, L.S.

    1977-01-01

    A method and apparatus for monitoring two-phase flow is provided that is particularly related to the monitoring of transient two-phase (liquid-vapor) flow rates such as may occur during a pressurized water reactor core blow-down. The present invention essentially comprises the use of flanged wire screens or similar devices, such as perforated plates, to produce certain desirable effects in the flow regime for monitoring purposes. One desirable effect is a measurable and reproducible pressure drop across the screen. The pressure drop can be characterized for various known flow rates and then used to monitor nonhomogeneous flow regimes. Another useful effect of the use of screens or plates in nonhomogeneous flow is that such apparatus tends to create a uniformly dispersed flow regime in the immediate downstream vicinity. This is a desirable effect because it usually increases the accuracy of flow rate measurements determined by conventional methods. 3 claims, 9 figures

  13. Single Pass Albumin Dialysis in Hepatorenal Syndrome

    Directory of Open Access Journals (Sweden)

    Rahman Ebadur

    2008-01-01

    Full Text Available Hepatorenal syndrome (HRS is the most appalling complication of acute or chronic liver disease with 90% mortality rate. Single pass albumin dialysis (SPAD can be considered as a noble liver support technique in HRS. Here, we present a case of a young healthy patient who developed hyperacute fulminant liver failure that progressed to HRS. The patient was offered SPAD as a bridge to liver transplantation, however, it resulted in an excellent recovery.

  14. Flow coating apparatus and method of coating

    Science.gov (United States)

    Hanumanthu, Ramasubrahmaniam; Neyman, Patrick; MacDonald, Niles; Brophy, Brenor; Kopczynski, Kevin; Nair, Wood

    2014-03-11

    Disclosed is a flow coating apparatus, comprising a slot that can dispense a coating material in an approximately uniform manner along a distribution blade that increases uniformity by means of surface tension and transfers the uniform flow of coating material onto an inclined substrate such as for example glass, solar panels, windows or part of an electronic display. Also disclosed is a method of flow coating a substrate using the apparatus such that the substrate is positioned correctly relative to the distribution blade, a pre-wetting step is completed where both the blade and substrate are completed wetted with a pre-wet solution prior to dispensing of the coating material onto the distribution blade from the slot and hence onto the substrate. Thereafter the substrate is removed from the distribution blade and allowed to dry, thereby forming a coating.

  15. Axioms for behavioural congruence of single-pass instruction sequences

    NARCIS (Netherlands)

    Bergstra, J.A.; Middelburg, C.A.

    2017-01-01

    In program algebra, an algebraic theory of single-pass instruction sequences, three congruences on instruction sequences are paid attention to: instruction sequence congruence, structural congruence, and behavioural congruence. Sound and complete axiom systems for the first two congruences were

  16. Method and apparatus for monitoring two-phase flow. [PWR

    Science.gov (United States)

    Sheppard, J.D.; Tong, L.S.

    1975-12-19

    A method and apparatus for monitoring two-phase flow is provided that is particularly related to the monitoring of transient two-phase (liquid-vapor) flow rates such as may occur during a pressurized water reactor core blow-down. The present invention essentially comprises the use of flanged wire screens or similar devices, such as perforated plates, to produce certain desirable effects in the flow regime for monitoring purposes. One desirable effect is a measurable and reproducible pressure drop across the screen. The pressure drop can be characterized for various known flow rates and then used to monitor nonhomogeneous flow regimes. Another useful effect of the use of screens or plates in nonhomogeneous flow is that such apparatus tends to create a uniformly dispersed flow regime in the immediate downstream vicinity. This is a desirable effect because it usually increases the accuracy of flow rate measurements determined by conventional methods.

  17. Pressurized water reactor flow skirt apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Kielb, John F.; Schwirian, Richard E.; Lee, Naugab E.; Forsyth, David R.

    2016-04-05

    A pressurized water reactor vessel having a flow skirt formed from a perforated cylinder structure supported in the lower reactor vessel head at the outlet of the downcomer annulus, that channels the coolant flow through flow holes in the wall of the cylinder structure. The flow skirt is supported at a plurality of circumferentially spaced locations on the lower reactor vessel head that are not equally spaced or vertically aligned with the core barrel attachment points, and the flow skirt employs a unique arrangement of hole patterns that assure a substantially balanced pressure and flow of the coolant over the entire underside of the lower core support plate.

  18. Single-Pass Clustering Algorithm Based on Storm

    Science.gov (United States)

    Fang, LI; Longlong, DAI; Zhiying, JIANG; Shunzi, LI

    2017-02-01

    The dramatically increasing volume of data makes the computational complexity of traditional clustering algorithm rise rapidly accordingly, which leads to the longer time. So as to improve the efficiency of the stream data clustering, a distributed real-time clustering algorithm (S-Single-Pass) based on the classic Single-Pass [1] algorithm and Storm [2] computation framework was designed in this paper. By employing this kind of method in the Topic Detection and Tracking (TDT) [3], the real-time performance of topic detection arises effectively. The proposed method splits the clustering process into two parts: one part is to form clusters for the multi-thread parallel clustering, the other part is to merge the generated clusters in the previous process and update the global clusters. Through the experimental results, the conclusion can be drawn that the proposed method have the nearly same clustering accuracy as the traditional Single-Pass algorithm and the clustering accuracy remains steady, computing rate increases linearly when increasing the number of cluster machines and nodes (processing threads).

  19. Apparatus for irradiating a continuously flowing stream of fluid

    International Nuclear Information System (INIS)

    Speir, L.G.; Adams, E.L.

    1984-01-01

    An apparatus for irradiating a continuously flowing stream of fluid is disclosed. The apparatus consists of a housing having a spherical cavity and a spherical moderator containing a radiation source positioned within the spherical cavity. The spherical moderator is of lesser diameter than the spherical cavity so as to define a spherical annular volume around the moderator. The housing includes fluid intake and output conduits which open onto the spherical cavity at diametrically opposite positions. Fluid flows through the cavity around the spherical moderator and is uniformly irradiated due to the 4π radiation geometry. The irradiation source, for example a 252 CF neutron source, is removable from the spherical moderator through a radial bore which extends outwardly to an opening on the outside of the housing. The radiation source may be routinely removed without interrupting the flow of fluid or breaching the containment of the fluid

  20. Evaluation of a single-pass continuous whole-body 16-MDCT protocol for patients with polytrauma.

    Science.gov (United States)

    Nguyen, Duy; Platon, Alexandra; Shanmuganathan, Kathirkamanathan; Mirvis, Stuart E; Becker, Christoph D; Poletti, Pierre-Alexandre

    2009-01-01

    The purpose of this study was to compare a conventional multiregional MDCT protocol with two continuous single-pass whole-body MDCT protocols in imaging of patients with polytrauma. Ninety patients with polytrauma underwent whole-body 16-MDCT with a conventional (n=30) or one of two single-pass (n=60) protocols. The conventional protocol included unenhanced scans of the head and cervical spine and contrast-enhanced helical scans (140 mL, 4 mL/s, 300 mg I/mL) of the thorax and abdomen. The single-pass protocols consisted of unenhanced scans of the head followed by one-sweep acquisition from the circle of Willis through the pubic symphysis with a biphasic (150 mL, 6 and 4 mL/s, 300 mg I/mL) or monophasic (110 mL, 4 mL/s, 400 mg I/mL) injection. Acquisition times and interval delays between head, chest, and abdominal scans were recorded. Contrast enhancement was measured in the aortic arch, liver, spleen, and kidney. Diagnostic image quality in the same areas was assessed on a 4-point scale. Median acquisition times for the single-pass protocols were significantly shorter (-42.5%) than the acquisition time for the conventional protocol. No significant differences were found in mean enhancement values in the aorta, liver, spleen, and kidney for the three protocols. The image quality with both single-pass protocols was better than that with the conventional protocol in assessment of the mediastinum and cervical spine (p<0.05). There was no significant difference between the single-pass protocols. Use of single-pass continuous whole-body MDCT protocols can significantly decrease examination time for patients with polytrauma and improve image quality compared with a conventional serial scan protocol. Monophasic injection with highly concentrated contrast medium can reduce injection flow rate and should therefore be preferred to a biphasic injection technique.

  1. New apparatus for liquid-liquid extraction, 'emulsion flow' extractor

    International Nuclear Information System (INIS)

    Yanase, Nobuyuki; Naganawa, Hirochika; Nagano, Tetsushi; Noro, Junji

    2011-01-01

    A simple and low-cost apparatus for continuous and efficient liquid-liquid extraction, which does not need continual mechanical forces (stirring, shaking, etc.) other than solution sending, has newly been developed. This apparatus, named 'emulsion flow' extractor, is composed of a column part where an emulsified state fluid flow (emulsion flow) is generated by spraying micrometer-sized droplets of an aqueous phase into an organic phase and a phase-separating part where the emulsion flow is destabilized by means of a sudden decrease in its vertical liner velocity due to a drastic increase in cross-section area of the emulsion flow passing through. In the present study, the performance of a desktop emulsion flow extractor in the extraction of Yb(III) and U(VI) from aqueous HNO 3 solutions into isooctane containing bis(2-ethylhexyl) phosphoric acid (D2EHPA) was evaluated. The mixing efficiency of the emulsion flow extractor was found to be comparable with that of a popular liquid-liquid extractor, mixer-settler. Moreover, the emulsion flow extractor proved to have an overwhelming advantage in terms of phase-separating ability. (author)

  2. Microgravity Flow Regime Data: Buoyancy and Mixing Apparatus Effects

    Science.gov (United States)

    Shephard, Adam; Best, Frederick

    2010-01-01

    Zero-g two-phase flow data set qualification and flight experiment design have not been standardized and as a result, agreement among researchers has not been reached regarding what experimental conditions adequately approximate those of microgravity. The effects of buoyancy forces and mixing apparatus on the flow regime transitions are presented in this study. The gravity conditions onboard zero-g aircraft are at best 10-3 g which is used to approximate the 10-5 g conditions of microgravity, thus the buoyancy forces present on zero-g aircraft can become significantly large and unrepresentative of microgravity. When buoyancy forces approach those of surface tension forces, buoyancy induced coalescence occurs. When discussing flow regime transitions, these large buoyancy forces lead to flow regime transitions which otherwise would not occur. The buoyancy attributes of the two-phase flow data sets available in the literature are evaluated to determine which data sets exhibit buoyancy induced transitions. Upon comparison of the representative data sets, the affects of different mixing apparatus can be seen in the superficial velocity flow regime maps.

  3. Milestone experiments for single pass UV/X-ray FELs

    International Nuclear Information System (INIS)

    Ben-Zvi, I.

    1994-01-01

    In the past decade, significant advances have been made in the theory and technology of high brightness electron beams and single pass FELS. These developments facilitate the construction of practical UV and X-ray FELs and has prompted proposals to the DOE for the construction of such facilities. There are several important experiments to be performed before committing to the construction of dedicated user facilities. Two experiments are under construction in the IR, the UCLA Self Amplified Spontaneous Emission experiment and the BNL laser seeded Harmonic Generation experiment. A multi-institution collaboration is being organized about a 210 MeV electron linac available at BNL and the 10 meter tong NISUS wiggler. This experiment will be done in the UV and will test various experimental aspects of electron beam dynamics, FEL exponential regime with gain guiding, start up from noise, seeding and harmonic generation. These experiments will advance the state of FEL research and lead towards future dedicated users' facilities

  4. Milestone experiments for single pass UV/X-ray FELs

    Science.gov (United States)

    Ben-Zvi, Ilan

    1995-04-01

    In the past decade, significant advances have been made in the theory and technology of high brightness electron beams and single pass FELs. These developments facilitate the construction of practical UV and X-ray FELs and has prompted proposals to the DOE for the construction of such facilities. There are several important experiments to be performed before committing to the construction of dedicated user facilities. Two experiments are under construction in the IR, the UCLA self-amplified spontaneous emission experiment and the BNL laser seeded harmonic generation experiment. A multi-institution collaboration is being organized about a 210 MeV electron linac available at BNL and the 10 m long NISUS wiggler. This experiment will be done in the UV and will test various experimental aspects of electron beam dynamics, FEL exponential regime with gain guiding, start-up from noise, seeding and harmonic generation. These experiments will advance the state of FEL research and lead towards future dedicated users' facilities.

  5. Experimental and simulation studies on a single pass, double duct solar air heater

    Energy Technology Data Exchange (ETDEWEB)

    Forson, F.K. [Kwame Nkrumah Univ. of Science and Technology, Dept. of Mechanical Engineering, Kumasi (Ghana); Rajakaruna, H. [De Montfort Univ., School of Engineering and Technology, Leicester (United Kingdom)

    2003-05-01

    A mathematical model of a single pass, double duct solar air heater (SPDDSAH) is described. The model provides a design tool capable of predicting: incident solar radiation, heat transfer coefficients, mean air flow rates, mean air temperature and relative humidity at the exit. Results from the simulation are presented and compared with experimental ones obtained on a full scale air heater and a small scale laboratory one. Reasonable agreement between the predicted and measured values is demonstrated. Predicted results from a parametric study are also presented. It is shown that significant improvement in the SPDDSAH performance can be obtained with an appropriate choice of the collector parameters and the top to bottom channel depth ratio of the two ducts. The air mass flow rate is shown to be the dominant factor in determining the overall efficiency of the heater. (Author)

  6. The Single Pass RF Driver: Final beam compression

    International Nuclear Information System (INIS)

    Burke, Robert

    2014-01-01

    The Single Pass RF Driver (SPRFD) compacts the beam from the linac without storage rings by manipulations that take advantage of the multiplicity of isotopes (16), the preserved µbunch structure, and increased total linac current. Magnetic switches on a first set of delay lines rearrange the internal structure of the various isotopic beams. A second set of delay lines sets the relative timing of the 16 isotopic beam sections so they will telescope at the pellet, in one of multiple fusion chambers, e.g. 10. Shortening each isotopic beam section uses preservation of the µbunch structure up to the final ∼2 km drift before final focus. Just before the final drift, differential acceleration of the µbunches in each isotopic beam section (128 total) launches an axial collapse, referred to as the “Slick”. The µbunches interpenetrate as their centers of mass move toward each other and individual µbunches lengthen due to their momentum spread. In longitudinal phase space they slide over one another as they lengthen in time and slim down in instantaneous energy spread. The permissible amount of µbunch lengthening is set by the design pulse shape at the pellet, which varies for different groups of isotopes. In narrow bands of ranges according to the role for each isotope group in the pellet, the ranges extend from 1 to 10 g/cm 2 to drive the cylinder barrel and thin hemispherical end caps, to heat the ∼0.5 g/cm 2 ρR fast ignition zone, and to improve the quasi-sphericity of the compression of the fast ignition zones at the pellet's ends. Because the µbunch–µbunch momentum differences are correlated, time-ramped beamline transport elements close after the differential accelerator are used to correct the associated shifts of focal point. Beam neutralization is needed after the differential acceleration until adjacent bunches begin to overlap. Concurrent collapse of each isotope and telescoping of the 16 isotopes cause the current in each beamline to rise

  7. Physical Modelling Of The Steel Flow In RH Apparatus

    Directory of Open Access Journals (Sweden)

    Pieprzyca J.

    2015-09-01

    Full Text Available The efficiency of vacuum steel degassing using RH methods depends on many factors. One of the most important are hydrodynamic processes occurring in the ladle and vacuum chamber. It is always hard and expensive to determine the flow character and the way of steel mixing in industrial unit; thus in this case, methods of physical modelling are applied. The article presents the results of research carried out on the water physical model of RH apparatus concerning the influence of the flux value of inert gas introduced through the suck legs on hydrodynamic conditions of the process. Results of the research have visualization character and are presented graphically as a RTD curves. The main aim of such research is to optimize the industrial vacuum steel degassing process by means of RH method.

  8. Model for Estimation of Thermal History Produced by a Single Pass Underwater Wet Weld

    National Research Council Canada - National Science Library

    Dill, Jay

    1997-01-01

    Thermal history calculations for single pass underwater wet weldments were made by solving the appropriate beat transfer equations using the three-dimensional Crank-Nicholson finite difference method...

  9. Error Analysis for High Resolution Topography with Bi-Static Single-Pass SAR Interferometry

    Science.gov (United States)

    Muellerschoen, Ronald J.; Chen, Curtis W.; Hensley, Scott; Rodriguez, Ernesto

    2006-01-01

    We present a flow down error analysis from the radar system to topographic height errors for bi-static single pass SAR interferometry for a satellite tandem pair. Because of orbital dynamics the baseline length and baseline orientation evolve spatially and temporally, the height accuracy of the system is modeled as a function of the spacecraft position and ground location. Vector sensitivity equations of height and the planar error components due to metrology, media effects, and radar system errors are derived and evaluated globally for a baseline mission. Included in the model are terrain effects that contribute to layover and shadow and slope effects on height errors. The analysis also accounts for nonoverlapping spectra and the non-overlapping bandwidth due to differences between the two platforms' viewing geometries. The model is applied to a 514 km altitude 97.4 degree inclination tandem satellite mission with a 300 m baseline separation and X-band SAR. Results from our model indicate that global DTED level 3 can be achieved.

  10. Purged window apparatus. [On-line spectroscopic analysis of gas flow systems

    Science.gov (United States)

    Ballard, E.O.

    1982-04-05

    A purged window apparatus is described which utilizes tangentially injected heated purge gases in the vicinity of electromagnetic radiation transmitting windows and a tapered external mounting tube to accelerate these gases to provide a vortex flow on the window surface and a turbulent flow throughout the mounting tube thereby preventing backstreaming of flowing gases under investigation in a chamber to which a plurality of similar purged apparatus is attached with the consequent result that spectroscopic analyses can be undertaken for lengthy periods without the necessity of interrupting the flow for cleaning or replacing the windows due to contamination.

  11. A mathematical analysis of drug dissolution in the USP flow through apparatus

    Science.gov (United States)

    McDonnell, David; D'Arcy, D. M.; Crane, L. J.; Redmond, Brendan

    2018-03-01

    This paper applies boundary layer theory to the process of drug dissolution in the USP (United States Pharmacopeia) Flow Through Apparatus. The mass transfer rate from the vertical planar surface of a compact within the device is examined. The theoretical results obtained are then compared with those of experiment. The paper also examines the effect on the dissolution process caused by the interaction between natural and forced convection within the apparatus and the introduction of additional boundaries.

  12. New liquid-liquid extraction apparatus, 'emulsion-flow' extractor

    International Nuclear Information System (INIS)

    Naganawa, Hirochika

    2017-01-01

    A new liquid-liquid extraction method, called the 'emulsion-flow' method, has recently been developed at Japan Atomic Energy Agency (JAEA). The emulsion-flow method, where low cost, simplicity, high efficiency, compactness, safety, and eco-friendly go together, has attracted attention, and has been expected to bring innovation to liquid-liquid extraction technologies. An apparatus based on the emulsion-flow method can actualize very efficient liquid-liquid extraction with its high two-phase mixing ability to an emulsion by spraying micrometer-sized oil droplets into a counter-current aqueous solution by only solution sending. Meanwhile, at the same time, the emulsion produced in the apparatus disappears rapidly and perfectly by drastically changing the cross-section where liquid droplets pass through in its vessel structure. Such a rapid and perfect phase separation can realize a high processing speed with a small-sized apparatus. Compared with conventional industrial apparatuses, an emulsion-flow apparatus successfully combines the lowest cost superior to a spray column and the highest performance (the highest efficiency and the highest processing speed) comparable to a centrifugal extractor. Furthermore, the emulsion-flow method can also be used for collecting particulate components by utilizing their aggregation onto a liquid-liquid interface and for purifying water polluted by oil with its remarkable phase-separating ability. (author)

  13. Highly efficient single-pass sum frequency generation by cascaded nonlinear crystals

    DEFF Research Database (Denmark)

    Hansen, Anders Kragh; Andersen, Peter E.; Jensen, Ole Bjarlin

    2015-01-01

    The cascading of nonlinear crystals has been established as a simple method to greatly increase the conversion efficiency of single-pass second-harmonic generation compared to a single-crystal scheme. Here, we show for the first time that the technique can be extended to sum frequency generation......, despite differences in the phase relations of the involved fields. An unprecedented 5.5 W of continuous-wave diffraction-limited green light is generated from the single-pass sum frequency mixing of two diode lasers in two periodically poled nonlinear crystals (conversion efficiency 50%). The technique...

  14. Simulation of Rocket-Grade Kerosene Flowing in an Electrically Heated Experimental Apparatus

    Science.gov (United States)

    2015-07-01

    Technical Paper 3. DATES COVERED (From - To) July 2015-July 2015 4. TITLE AND SUBTITLE Simulation of Rocket Kerosene Flowing in an Electrically Heated...rocket-grade kerosene (RP-2) flowing in an electrically heated tube is simulated. The model and boundary conditions are selected so as to simulate an...and Astronautics 1 Simulation of Rocket-Grade Kerosene Flowing in an Electrically Heated Experimental Apparatus Ananda Himansu1 and Matthew C

  15. Apparatus and method for using radar to evaluate wind flow fields for wind energy applications

    Science.gov (United States)

    Schroeder, John; Hirth, Brian; Guynes, Jerry

    2017-02-21

    The present invention provides an apparatus and method for obtaining data to determine one or more characteristics of a wind flow field using one or more radars. Data is collected from the one or more radars, and analyzed to determine the one or more characteristics of the wind flow field. The one or more radars are positioned to have a portion of the wind flow field within a scanning sector of the one or more radars.

  16. Fuel-element failures in Hanford single-pass reactors 1944--1971

    Energy Technology Data Exchange (ETDEWEB)

    Gydesen, S.P.

    1993-07-01

    The primary objective of the Hanford Environmental Dose Reconstruction (HEDR) Project is to estimate the radiation dose that individuals could have received as a result of emissions since 1944 from the US Department of Energy`s (DOE) Hanford Site near Richland, Washington. To estimate the doses, the staff of the Source Terms Task use operating information from historical documents to approximate the radioactive emissions. One source of radioactive emissions to the Columbia River came from leaks in the aluminum cladding of the uranium metal fuel elements in single-pass reactors. The purpose of this letter report is to provide photocopies of the documents that recorded these failures. The data from these documents will be used by the Source Terms Task to determine the contribution of single-pass reactor fuel-element failures to the radioactivity of the reactor effluent from 1944 through 1971. Each referenced fuel-element failure occurring in the Hanford single-pass reactors is addressed. The first recorded failure was in 1948, the last in 1970. No records of fuel-element failures were found in documents prior to 1948. Data on the approximately 2000 failures which occurred during the 28 years (1944--1971) of Hanford single-pass reactor operations are provided in this report.

  17. Fuel-element failures in Hanford single-pass reactors 1944--1971

    International Nuclear Information System (INIS)

    Gydesen, S.P.

    1993-07-01

    The primary objective of the Hanford Environmental Dose Reconstruction (HEDR) Project is to estimate the radiation dose that individuals could have received as a result of emissions since 1944 from the US Department of Energy's (DOE) Hanford Site near Richland, Washington. To estimate the doses, the staff of the Source Terms Task use operating information from historical documents to approximate the radioactive emissions. One source of radioactive emissions to the Columbia River came from leaks in the aluminum cladding of the uranium metal fuel elements in single-pass reactors. The purpose of this letter report is to provide photocopies of the documents that recorded these failures. The data from these documents will be used by the Source Terms Task to determine the contribution of single-pass reactor fuel-element failures to the radioactivity of the reactor effluent from 1944 through 1971. Each referenced fuel-element failure occurring in the Hanford single-pass reactors is addressed. The first recorded failure was in 1948, the last in 1970. No records of fuel-element failures were found in documents prior to 1948. Data on the approximately 2000 failures which occurred during the 28 years (1944--1971) of Hanford single-pass reactor operations are provided in this report

  18. A method and apparatus for analysing and sorting a flow of material

    NARCIS (Netherlands)

    Dalmijn, W.L.; De Jong, T.P.R.

    2002-01-01

    The invention relates to a method and an apparatus for analysing a flow of material using X rays. The method comprises radiating the material with at least two energy levels and measuring the transmission of radiation through the material for each level separately, and is characterized in that a

  19. Thermal treatment of starch slurry in Couette-Taylor flow apparatus

    Directory of Open Access Journals (Sweden)

    Hubacz Robert

    2017-09-01

    Full Text Available In this paper, thermal processing of starch slurry in a Couette-Taylor flow (CTF apparatus was investigated. Gelatinized starch dispersion, after treatment in the CTF apparatus, was characterized using such parameters like starch granule diameters (or average diameter, starch granule swelling degree (quantifying the amount of water absorbed by starch granules and concentration of dissolved starch. These parameters were affected mostly by the process temperature, although the impact of the axial flow or rotor rotation on them was also observed. Moreover, the analysis of results showed a relatively good correlation between these parameters, as well as, between those parameter and apparent viscosity of gelatinized starch dispersion. Meanwhile, the increase in the value of the apparent viscosity and in shear-tinning behaviour of dispersion was associated with the progress of starch processing in the CTF apparatus. Finally, the CTF apparatuses of different geometries were compared using numerical simulation of the process. The results of the simulation indicated that the apparatus scaling-up without increasing the width of the gap between cylinders results in higher mechanical energy consumption per unit of processed starch slurry.

  20. Method and apparatus for chemically altering fluids in continuous flow

    Science.gov (United States)

    Heath, William O.; Virden, Jr., Judson W.; Richardson, R. L.; Bergsman, Theresa M.

    1993-01-01

    The present invention relates to a continuous flow fluid reactor for chemically altering fluids. The reactor operates on standard frequency (50 to 60 Hz) electricity. The fluid reactor contains particles that are energized by the electricity to form a corona throughout the volume of the reactor and subsequently a non-equilibrium plasma that interacts with the fluid. Particles may form a fixed bed or a fluid bed. Electricity may be provided through electrodes or through an inductive coil. Fluids include gases containing exhaust products and organic fuels requiring oxidation.

  1. Flow method and apparatus for screening chemicals using micro x-ray fluorescence

    Science.gov (United States)

    Warner, Benjamin P [Los Alamos, NM; Havrilla, George J [Los Alamos, NM; Miller, Thomasin C [Bartlesville, OK; Lewis, Cris [Los Alamos, NM; Mahan, Cynthia A [Los Alamos, NM; Wells, Cyndi A [Los Alamos, NM

    2009-04-14

    Method and apparatus for screening chemicals using micro x-ray fluorescence. A method for screening a mixture of potential pharmaceutical chemicals for binding to at least one target binder involves flow-separating a solution of chemicals and target binders into separated components, exposing them to an x-ray excitation beam, detecting x-ray fluorescence signals from the components, and determining from the signals whether or not a binding event between a chemical and target binder has occurred.

  2. High-aspect-ratio grooves fabricated in silicon by a single pass of femtosecond laser pulses

    International Nuclear Information System (INIS)

    Ma Yuncan; Shi Haitao; Si Jinhai; Ren Hai; Chen Tao; Chen Feng; Hou Xun

    2012-01-01

    High-aspect-ratio grooves have been fabricated in silicon by a single pass of femtosecond laser pulses in water and ambient air. Scanning electron microscopy and energy dispersive x-ray spectroscopy were employed to image for the morphology of the photoinduced grooves and analyze the chemical composition in the surrounding of the grooves. It was observed that the sidewall of the grooves fabricated in water was much smoother than that in ambient air, and there were homogeneous nano-scale protrusions on the sidewall of the grooves fabricated in water. Meanwhile, oxygen species, which was incorporated into the grooves fabricated in air, was not observed in those in water.

  3. Generic, network schema agnostic sparse tensor factorization for single-pass clustering of heterogeneous information networks.

    Directory of Open Access Journals (Sweden)

    Jibing Wu

    Full Text Available Heterogeneous information networks (e.g. bibliographic networks and social media networks that consist of multiple interconnected objects are ubiquitous. Clustering analysis is an effective method to understand the semantic information and interpretable structure of the heterogeneous information networks, and it has attracted the attention of many researchers in recent years. However, most studies assume that heterogeneous information networks usually follow some simple schemas, such as bi-typed networks or star network schema, and they can only cluster one type of object in the network each time. In this paper, a novel clustering framework is proposed based on sparse tensor factorization for heterogeneous information networks, which can cluster multiple types of objects simultaneously in a single pass without any network schema information. The types of objects and the relations between them in the heterogeneous information networks are modeled as a sparse tensor. The clustering issue is modeled as an optimization problem, which is similar to the well-known Tucker decomposition. Then, an Alternating Least Squares (ALS algorithm and a feasible initialization method are proposed to solve the optimization problem. Based on the tensor factorization, we simultaneously partition different types of objects into different clusters. The experimental results on both synthetic and real-world datasets have demonstrated that our proposed clustering framework, STFClus, can model heterogeneous information networks efficiently and can outperform state-of-the-art clustering algorithms as a generally applicable single-pass clustering method for heterogeneous network which is network schema agnostic.

  4. Test Methodologies for Hydrogen Sensor Performance Assessment: Chamber vs. Flow Through Test Apparatus: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Buttner, William J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Hartmann, Kevin S [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Schmidt, Kara [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Cebolla, Rafeal O [Joint Research Centre, Petten, the Netherlands; Weidner, Eveline [Joint Research Centre, Petten, the Netherlands; Bonato, Christian [Joint Research Centre, Petten, the Netherlands

    2017-11-06

    Certification of hydrogen sensors to standards often prescribes using large-volume test chambers [1, 2]. However, feedback from stakeholders such as sensor manufacturers and end-users indicate that chamber test methods are often viewed as too slow and expensive for routine assessment. Flow through test methods potentially are an efficient, cost-effective alternative for sensor performance assessment. A large number of sensors can be simultaneously tested, in series or in parallel, with an appropriate flow through test fixture. The recent development of sensors with response times of less than 1s mandates improvements in equipment and methodology to properly capture the performance of this new generation of fast sensors; flow methods are a viable approach for accurate response and recovery time determinations, but there are potential drawbacks. According to ISO 26142 [1], flow through test methods may not properly simulate ambient applications. In chamber test methods, gas transport to the sensor can be dominated by diffusion which is viewed by some users as mimicking deployment in rooms and other confined spaces. Alternatively, in flow through methods, forced flow transports the gas to the sensing element. The advective flow dynamics may induce changes in the sensor behaviour relative to the quasi-quiescent condition that may prevail in chamber test methods. One goal of the current activity in the JRC and NREL sensor laboratories [3, 4] is to develop a validated flow through apparatus and methods for hydrogen sensor performance testing. In addition to minimizing the impact on sensor behaviour induced by differences in flow dynamics, challenges associated with flow through methods include the ability to control environmental parameters (humidity, pressure and temperature) during the test and changes in the test gas composition induced by chemical reactions with upstream sensors. Guidelines on flow through test apparatus design and protocols for the evaluation of

  5. High-Accuracy Elevation Data at Large Scales from Airborne Single-Pass SAR Interferometry

    Directory of Open Access Journals (Sweden)

    Guy Jean-Pierre Schumann

    2016-01-01

    Full Text Available Digital elevation models (DEMs are essential data sets for disaster risk management and humanitarian relief services as well as many environmental process models. At present, on the hand, globally available DEMs only meet the basic requirements and for many services and modeling studies are not of high enough spatial resolution and lack accuracy in the vertical. On the other hand, LiDAR-DEMs are of very high spatial resolution and great vertical accuracy but acquisition operations can be very costly for spatial scales larger than a couple of hundred square km and also have severe limitations in wetland areas and under cloudy and rainy conditions. The ideal situation would thus be to have a DEM technology that allows larger spatial coverage than LiDAR but without compromising resolution and vertical accuracy and still performing under some adverse weather conditions and at a reasonable cost. In this paper, we present a novel single pass In-SAR technology for airborne vehicles that is cost-effective and can generate DEMs with a vertical error of around 0.3 m for an average spatial resolution of 3 m. To demonstrate this capability, we compare a sample single-pass In-SAR Ka-band DEM of the California Central Valley from the NASA/JPL airborne GLISTIN-A to a high-resolution LiDAR DEM. We also perform a simple sensitivity analysis to floodplain inundation. Based on the findings of our analysis, we argue that this type of technology can and should be used to replace large regions of globally available lower resolution DEMs, particularly in coastal, delta and floodplain areas where a high number of assets, habitats and lives are at risk from natural disasters. We conclude with a discussion on requirements, advantages and caveats in terms of instrument and data processing.

  6. Experimental evaluation and set-up of a new apparatus designed for transitional flow experiments

    Directory of Open Access Journals (Sweden)

    Rozehnal Dalibor

    2012-04-01

    Full Text Available Experimental exercise has been conducted to validate the capability of a new test apparatus. The test stand has been designed and constructed at the laboratory of aerodynamics, University of Defence to carry out the experimental investigation of transitional flow prediction and development over flat plate. The test facility consists of a rectangular duct set on the suction side of air source apparatus. The working section is 2 m long with a cross section of 0.44 m in width and 0.25 m in height. The exercise is performed into two stages. In the first stage, the basic parameters such as freestream velocity, turbulence intensity and pressure gradient in streamwise direction were measured and manipulated to setup acceptable values. Second stage of the exercise, the bottom wall of the test section was used as a flat plate model to conduct turbulent boundary-layer experiment. The characteristics of the boundary layer obtained by using the apparatus are represented by a qualitative and quantitative agreement with those predicted by boundary-layer theory for turbulent boundary layer while more improvements seems to be required to satisfy the rules of boundary layer stability experiments. The results are show a fair agreement for mean velocity profile, U∞, boundary layer thickness, δ, momentum thickness, θ, and skin friction coefficient, Cf.

  7. Permeable barrier materials for strontium immobilization: Unsaturated flow apparatus determination of hydraulic conductivity -- Column sorption experiments

    International Nuclear Information System (INIS)

    Moody, T.E.; Conca, J.

    1996-09-01

    Selected materials were tested to emulate a permeable barrier and to examine the (1) capture efficiency of these materials relating to the immobilization of strontium-90 and hexavalent chromium (Cr 6+ ) in Hanford Site groundwater; and (2) hydraulic conductivity of the barrier material relative to the surrounding area. The emplacement method investigated was a permeable reactive barrier to treat contaminated groundwater as it passes through the barrier. The hydraulic conductivity function was measured for each material, and retardation column experiments were performed for each material. Measurements determining the hydraulic conductivity at unsaturated through saturated water content were executed using the Unsaturated Flow Apparatus

  8. Method and apparatus for simultaneous determination of fluid mass flow rate, mean velocity and density

    International Nuclear Information System (INIS)

    Hamel, W.R.

    1984-01-01

    This invention relates to a new method and new apparatus for determining fluid mass flow rate and density. In one aspect of the invention, the fluid is passed through a straight cantilevered tube in which transient oscillation has been induced, thus generating Coriolis damping forces on the tube. The decay rate and frequency of the resulting damped oscillation are measured, and the fluid mass flow rate and density are determined therefrom. In another aspect of the invention, the fluid is passed through the cantilevered tube while an electrically powered device imparts steady-state harmonic excitation to the tube. This generates Coriolis tube-damping forces which are dependent on the mass flow rate of the fluid. Means are provided to respond to incipient flow-induced changes in the amplitude of vibration by changing the power input to the excitation device as required to sustain the original amplitude of vibration. The fluid mass flow rate and density are determined from the required change in power input. The invention provides stable, rapid, and accurate measurements. It does not require bending of the fluid flow

  9. Safety and efficacy of high fluence CO2 laser skin resurfacing with a single pass.

    Science.gov (United States)

    Khosh, M M; Larrabee, W F; Smoller, B

    1999-01-01

    Carbon dioxide (CO2) laser skin resurfacing has nearly replaced more traditional methods of superficial skin rejuvenation. Post-treatment erythema is the most common side effect of this method of skin resurfacing. Sublethal thermal damage to the dermis has been proposed as an etiology for post laser erythema. Recent developments in laser resurfacing technology have aimed at minimizing thermal damage to the dermis. To determine depth of skin ablation, extent of thermal injury, and ideal laser parameters for the FeatherTouch laser system. To assess the safety and efficacy of laser resurfacing at high energy fluences with a single pass. Laser resurfacing was performed in the preauricular skin of five patients undergoing rhytidectomy. A total of 60 sites were tested with fluences of 7 to 17 Joules/cm2. Histologic evaluation of excised skin showed maximal thermal injury to be restricted to 60 microns in the papillary dermis. The reticular dermis showed no evidence of injury. Based on these findings, laser resurfacing at 17 J/cm2 (70 watts) was performed on 30 patients (in the periorbital area, a maximum of 9 J/cm2 or 36 watts was used). Follow up ranged between 12 and 18 months. Based on histologic comparison of average and high fluence laser resurfacing, high fluence laser resurfacing did not cause added thermal damage to the reticular dermis. In the clinical group, no major complications such as scarring, scleral show, infection or ectropion were encountered. Transient hyperpigmentation was noted in three patients. Overall patient satisfaction was good to excellent. Post-treatment erythema lasted an average of 4 weeks. We conclude that CO2 laser resurfacing of the face (excluding the periorbital region) can be performed safely and effectively, with the FeatherTouch laser, at 17 J/cm2 with one pass. In our group of patients, laser resurfacing with a single pass at 17 J/cm2 caused less post-operative erythema than two or more passes at 9 J/cm2.

  10. Parametric analysis of plastic strain and force distribution in single pass metal spinning

    Energy Technology Data Exchange (ETDEWEB)

    Choudhary, Shashank, E-mail: shashankbit08@gmail.com, E-mail: mohantejesh93@gmail.com, E-mail: regalla@hyderabad.bits-pilani.ac.in, E-mail: ksuresh@hyderabad.bits-pilani.ac.in; Tejesh, Chiruvolu Mohan, E-mail: shashankbit08@gmail.com, E-mail: mohantejesh93@gmail.com, E-mail: regalla@hyderabad.bits-pilani.ac.in, E-mail: ksuresh@hyderabad.bits-pilani.ac.in; Regalla, Srinivasa Prakash, E-mail: shashankbit08@gmail.com, E-mail: mohantejesh93@gmail.com, E-mail: regalla@hyderabad.bits-pilani.ac.in, E-mail: ksuresh@hyderabad.bits-pilani.ac.in; Suresh, Kurra, E-mail: shashankbit08@gmail.com, E-mail: mohantejesh93@gmail.com, E-mail: regalla@hyderabad.bits-pilani.ac.in, E-mail: ksuresh@hyderabad.bits-pilani.ac.in [Department of Mechanical Engineering, BITS-Pilani, Hyderabad Campus, Shamirpet, Hyderabad, 500078, Andhra Pradesh (India)

    2013-12-16

    Metal spinning also known as spin forming is one of the sheet metal working processes by which an axis-symmetric part can be formed from a flat sheet metal blank. Parts are produced by pressing a blunt edged tool or roller on to the blank which in turn is mounted on a rotating mandrel. This paper discusses about the setting up a 3-D finite element simulation of single pass metal spinning in LS-Dyna. Four parameters were considered namely blank thickness, roller nose radius, feed ratio and mandrel speed and the variation in forces and plastic strain were analysed using the full-factorial design of experiments (DOE) method of simulation experiments. For some of these DOE runs, physical experiments on extra deep drawing (EDD) sheet metal were carried out using En31 tool on a lathe machine. Simulation results are able to predict the zone of unsafe thinning in the sheet and high forming forces that are hint to the necessity for less-expensive and semi-automated machine tools to help the household and small scale spinning workers widely prevalent in India.

  11. Capacitive deionization of arsenic-contaminated groundwater in a single-pass mode.

    Science.gov (United States)

    Fan, Chen-Shiuan; Liou, Sofia Ya Hsuan; Hou, Chia-Hung

    2017-10-01

    A single-pass-mode capacitive deionization (CDI) reactor was used to remove arsenic from groundwater in the presence of multiple ions. The CDI reactor involved an applied voltage of 1.2 V and six cell pairs of activated carbon electrodes, each of which was 20 × 30 cm 2 . The results indicate that this method achieved an effluent arsenic concentration of 0.03 mg L -1 , which is lower than the arsenic concentration standard for drinking water and irrigation sources in Taiwan, during the charging stage. Additionally, the ability of the CDI to remove other coexisting ions was studied. The presence of other ions has a significant influence on the removal of arsenic from groundwater. From the analysis of the electrosorption selectivity, the preference for anion removal could be ordered as follows: NO 3 -  > SO 4 2-  > F -  > Cl - >As. The electrosorption selectivity for cations could be ordered as follows: Ca 2+  > Mg 2+  > Na +  ∼ K + . Moreover, monovalent cations can be replaced by divalent cations at the electrode surface in the later period of the electrosorption stage. Consequently, activated carbon-based capacitive deionization is demonstrated to be a high-potential technology for remediation of arsenic-contaminated groundwater. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Low energy dark current collimation system in single-pass linacs

    Science.gov (United States)

    Bettoni, S.; Craievich, P.; Pedrozzi, M.; Schaer, M.; Stingelin, L.

    2018-02-01

    The dark current emitted from a surface of a radio frequency cavity may be a severe issue for the activation and the protection of the components of linear accelerators, if this current is lost in an uncontrolled manner. For a single-pass linac based on a photo-injector, we studied the possibility of using a collimator installed at low energy (below 10 MeV) to dump the maximum fraction of the dark current before it is transported along the linac. We developed and experimentally verified an emission and tracking model that we used to study and optimize the dark current mitigation at SwissFEL test facility. We optimized a collimator, which is expected to reduce by two orders of magnitude the transport of the dark current to the first compressor. We have also verified the effects of wakefield excited by the beam itself passing through the collimator at such a low energy, comparing the results of beam-based measurements with an analytical model.

  13. Non-destructive single-pass low-noise detection of ions in a beamline

    Science.gov (United States)

    Schmidt, Stefan; Murböck, Tobias; Andelkovic, Zoran; Birkl, Gerhard; Nörtershäuser, Wilfried; Stahl, Stefan; Vogel, Manuel

    2015-11-01

    We have conceived, built, and operated a device for the non-destructive single-pass detection of charged particles in a beamline. The detector is based on the non-resonant pick-up and subsequent low-noise amplification of the image charges induced in a cylindrical electrode surrounding the particles' beam path. The first stage of the amplification electronics is designed to be operated from room temperature down to liquid helium temperature. The device represents a non-destructive charge counter as well as a sensitive timing circuit. We present the concept and design details of the device. We have characterized its performance and show measurements with low-energy highly charged ions (such as Ar13+) passing through one of the electrodes of a cylindrical Penning trap. This work demonstrates a novel approach of non-destructive, low noise detection of charged particles which is, depending on the bunch structure, suitable, e.g., for ion traps, low-energy beamlines or accelerator transfer sections.

  14. Method and Apparatus for Predicting Unsteady Pressure and Flow Rate Distribution in a Fluid Network

    Science.gov (United States)

    Majumdar, Alok K. (Inventor)

    2009-01-01

    A method and apparatus for analyzing steady state and transient flow in a complex fluid network, modeling phase changes, compressibility, mixture thermodynamics, external body forces such as gravity and centrifugal force and conjugate heat transfer. In some embodiments, a graphical user interface provides for the interactive development of a fluid network simulation having nodes and branches. In some embodiments, mass, energy, and specific conservation equations are solved at the nodes, and momentum conservation equations are solved in the branches. In some embodiments, contained herein are data objects for computing thermodynamic and thermophysical properties for fluids. In some embodiments, the systems of equations describing the fluid network are solved by a hybrid numerical method that is a combination of the Newton-Raphson and successive substitution methods.

  15. Narrow conductive structures with high aspect ratios through single-pass inkjet printing and evaporation-induced dewetting

    NARCIS (Netherlands)

    Abbel, R.; Teunissen, P.; Michels, J.; Groen, W.A.

    2015-01-01

    Inkjet printed silver lines contract to widths below 20-μm during drying on an organic planarization coating. Aspect ratios previously unprecedented with single pass inkjet printing on isotropic homogeneous substrates are obtained. This effect is caused by the subsequent evaporation of solvents from

  16. Method and apparatus for controlling the flow rate of mercury in a flow system

    Science.gov (United States)

    Grossman, Mark W.; Speer, Richard

    1991-01-01

    A method for increasing the mercury flow rate to a photochemical mercury enrichment utilizing an entrainment system comprises the steps of passing a carrier gas over a pool of mercury maintained at a first temperature T1, wherein the carrier gas entrains mercury vapor; passing said mercury vapor entrained carrier gas to a second temperature zone T2 having temperature less than T1 to condense said entrained mercury vapor, thereby producing a saturated Hg condition in the carrier gas; and passing said saturated Hg carrier gas to said photochemical enrichment reactor.

  17. Method and apparatus for monitoring the flow of mercury in a system

    Science.gov (United States)

    Grossman, M.W.

    1987-12-15

    An apparatus and method for monitoring the flow of mercury in a system are disclosed. The equipment enables the entrainment of the mercury in a carrier gas e.g., an inert gas, which passes as mercury vapor between a pair of optically transparent windows. The attenuation of the emission is indicative of the quantity of mercury (and its isotopes) in the system. A 253.7 nm light is shone through one of the windows and the unabsorbed light is detected through the other window. The absorption of the 253.7 nm light is thereby measured whereby the quantity of mercury passing between the windows can be determined. The apparatus includes an in-line sensor for measuring the quantity of mercury. It includes a conduit together with a pair of apertures disposed in a face to face relationship and arranged on opposite sides of the conduit. A pair of optically transparent windows are disposed upon a pair of viewing tubes. A portion of each of the tubes is disposed inside of the conduit and within each of the apertures. The two windows are disposed in a face to face relationship on the ends of the viewing tubes and the entire assembly is hermetically sealed from the atmosphere whereby when 253.7 nm ultraviolet light is shone through one of the windows and detected through the other, the quantity of mercury which is passing by can be continuously monitored due to absorption which is indicated by attenuation of the amplitude of the observed emission. 4 figs.

  18. Method and apparatus for simultaneous determination of fluid mass flow rate, mean velocity and density

    Science.gov (United States)

    Hamel, William R.

    1984-01-01

    This invention relates to a new method and new apparatus for determining fluid mass flowrate and density. In one aspect of the invention, the fluid is passed through a straight cantilevered tube in which transient oscillation has been induced, thus generating Coriolis damping forces on the tube. The decay rate and frequency of the resulting damped oscillation are measured, and the fluid mass flowrate and density are determined therefrom. In another aspect of the invention, the fluid is passed through the cantilevered tube while an electrically powered device imparts steady-state harmonic excitation to the tube. This generates Coriolis tube-damping forces which are dependent on the mass flowrate of the fluid. Means are provided to respond to incipient flow-induced changes in the amplitude of vibration by changing the power input to the excitation device as required to sustain the original amplitude of vibration. The fluid mass flowrate and density are determined from the required change in power input. The invention provides stable, rapid, and accurate measurements. It does not require bending of the fluid flow.

  19. Removal efficiency of radioactive cesium and iodine ions by a flow-type apparatus designed for electrochemically reduced water production.

    Directory of Open Access Journals (Sweden)

    Takeki Hamasaki

    Full Text Available The Fukushima Daiichi Nuclear Power Plant accident on March 11, 2011 attracted people's attention, with anxiety over possible radiation hazards. Immediate and long-term concerns are around protection from external and internal exposure by the liberated radionuclides. In particular, residents living in the affected regions are most concerned about ingesting contaminated foodstuffs, including drinking water. Efficient removal of radionuclides from rainwater and drinking water has been reported using several pot-type filtration devices. A currently used flow-type test apparatus is expected to simultaneously provide radionuclide elimination prior to ingestion and protection from internal exposure by accidental ingestion of radionuclides through the use of a micro-carbon carboxymethyl cartridge unit and an electrochemically reduced water production unit, respectively. However, the removability of radionuclides from contaminated tap water has not been tested to date. Thus, the current research was undertaken to assess the capability of the apparatus to remove radionuclides from artificially contaminated tap water. The results presented here demonstrate that the apparatus can reduce radioactivity levels to below the detection limit in applied tap water containing either 300 Bq/kg of 137Cs or 150 Bq/kg of 125I. The apparatus had a removal efficiency of over 90% for all concentration ranges of radio-cesium and -iodine tested. The results showing efficient radionuclide removability, together with previous studies on molecular hydrogen and platinum nanoparticles as reactive oxygen species scavengers, strongly suggest that the test apparatus has the potential to offer maximum safety against radionuclide-contaminated foodstuffs, including drinking water.

  20. Simplified models of the symmetric single-pass parallel-plate counterflow heat exchanger: a tutorial.

    Science.gov (United States)

    Pickard, William F; Abraham-Shrauner, Barbara

    2018-03-01

    The heat exchanger is important in practical thermal processes, especially those of (i) the molten-salt storage schemes, (ii) compressed air energy storage schemes and (iii) other load-shifting thermal storage presumed to undergird a Smart Grid. Such devices, although central to the utilization of energy from sustainable (but intermittent) renewable sources, will be unfamiliar to many scientists, who nevertheless need a working knowledge of them. This tutorial paper provides a largely self-contained conceptual introduction for such persons. It begins by modelling a novel quantized exchanger, impractical as a device, but useful for comprehending the underlying thermophysics. It then reviews the one-dimensional steady-state idealization which demonstrates that effectiveness of heat transfer increases monotonically with (device length)/(device throughput). Next, it presents a two-dimensional steady-state idealization for plug flow and from it derives a novel formula for effectiveness of transfer; this formula is then shown to agree well with a finite-difference time-domain solution of the two-dimensional idealization under Hagen-Poiseuille flow. These results are consistent with a conclusion that effectiveness of heat exchange can approach unity, but may involve unwelcome trade-offs among device cost, size and throughput.

  1. Thermo-Mechanical Analysis of a Single-Pass Weld Overlay and Girth Welding in Lined Pipe

    Science.gov (United States)

    Obeid, Obeid; Alfano, Giulio; Bahai, Hamid

    2017-08-01

    The paper presents a nonlinear heat-transfer and mechanical finite-element (FE) analyses of a two-pass welding process of two segments of lined pipe made of a SUS304 stainless steel liner and a C-Mn steel pipe. The two passes consist of the single-pass overlay welding (inner lap weld) of the liner with the C-Mn steel pipe for each segment and the single-pass girth welding (outer butt weld) of the two segments. A distributed power density of the moving welding torch and a nonlinear heat-transfer coefficient accounting for both radiation and convection have been used in the analysis and implemented in user subroutines for the FE code ABAQUS. The modeling procedure has been validated against previously published experimental results for stainless steel and carbon steel welding separately. The model has been then used to determine the isotherms induced by the weld overlay and the girth welding and to clarify their influence on the transient temperature field and residual stress in the lined pipe. Furthermore, the influence of the cooling time between weld overlay and girth welding and of the welding speed have been examined thermally and mechanically as they are key factors that can affect the quality of lined pipe welding.

  2. Outdoor Storage Characteristics of Single-Pass Large Square Corn Stover Bales in Iowa

    Directory of Open Access Journals (Sweden)

    Ajay Shah

    2011-10-01

    Full Text Available Year-round operation of biorefineries can be possible only if the continuous flow of cellulosic biomass is guaranteed. If corn (Zea mays stover is the primary cellulosic biomass, it is essential to recognize that this feedstock has a short annual harvest window (≤1–2 months and therefore cost effective storage techniques that preserve feedstock quality must be identified. This study evaluated two outdoor and one indoor storage strategies for corn stover bales in Iowa. High- and low-moisture stover bales were prepared in the fall of 2009, and stored either outdoors with two different types of cover (tarp and breathable film or within a building for 3 or 9 months. Dry matter loss (DML, changes in moisture and biomass compositions (fiber and ultimate analyses were determined. DML for bales stored outdoor with tarp and breathable film covers were in the ranges of 5–11 and 14–17%, respectively. More than half of the total DML occurred early during the storage. There were measurable differences in carbon, hydrogen, nitrogen, sulfur, oxygen, cellulose, hemi-cellulose and acid detergent lignin for the different storage treatments, but the changes were small and within a narrow range. For the bale storage treatments investigated, cellulose content increased by as much as 4%s from an initial level of ~41%, hemicellulose content changed by −2 to 1% from ~34%, and acid detergent lignin contents increased by as much as 3% from an initial value of ~5%. Tarp covered bales stored the best in this study, but other methods, such as tube-wrapping, and economics need further investigation.

  3. Single Pass Laser Welding with Multiple Spots to Join Four Sheets in a Butt-joint Configuration

    Science.gov (United States)

    Kristiansen, Morten; Hansen, Klaus Schütt; Langbak, Andreas; Johansen, Sebastian Blegebrønd; Krempin, Simon Borup; Hornum, Mattias Døssing

    Laser keyhole welding is widely used in industry due to its large welding depth and low heat input. For some industrial cases it is necessary to widen the beam to cover the joint configuration, which instead results in a lower intensity and surface conduction welds. The introduction of the high-power single mode fiber laser makes it possible to deal with this problem, because the beam can be shaped into a pre-defined pattern of multiple spots shaped to the actual joint configuration. The intensity of each spot is sufficient to make a keyhole. A case with four sheets in a butt-joint configuration is used to demonstrate the principle of how to design a spot pattern which ensures weld quality in case of a single pass laser weld.

  4. Lucretia A Matlab-Based Toolbox for the Modeling and Simulation of Single-Pass Electron Beam Transport Systems

    CERN Document Server

    Tenenbaum, P G

    2005-01-01

    We report on Lucretia, a new simulation tool for the study of single-pass electron beam transport systems. Lucretia supports a combination of analytic and tracking techniques to model the tuning and operation of bunch compressors, linear accelerators, and beam delivery systems of linear colliders and linac-driven Free Electron Laser (FEL) facilities. Extensive use of Matlab scripting, graphics, and numerical capabilities maximize the flexibility of the system, and emphasis has been placed on representing and preserving the fixed relationships between elements (common girders, power supplies, etc.) which must be respected in the design of tuning algorithms. An overview of the code organization, some simple examples, and plans for future development are discussed.

  5. Testing the single-pass VOC removal efficiency of an active green wall using methyl ethyl ketone (MEK).

    Science.gov (United States)

    Torpy, Fraser; Clements, Nicholas; Pollinger, Max; Dengel, Andy; Mulvihill, Isaac; He, Chuan; Irga, Peter

    2018-01-01

    In recent years, research into the efficacy of indoor air biofiltration mechanisms, notably living green walls, has become more prevalent. Whilst green walls are often utilised within the built environment for their biophilic effects, there is little evidence demonstrating the efficacy of active green wall biofiltration for the removal of volatile organic compounds (VOCs) at concentrations found within an interior environment. The current work describes a novel approach to quantifying the VOC removal effectiveness by an active living green wall, which uses a mechanical system to force air through the substrate and plant foliage. After developing a single-pass efficiency protocol to understand the immediate effects of the system, the active green wall was installed into a 30-m 3 chamber representative of a single room and presented with the contaminant 2-butanone (methyl ethyl ketone; MEK), a VOC commonly found in interior environments through its use in textile and plastic manufacture. Chamber inlet levels of MEK remained steady at 33.91 ± 0.541 ppbv. Utilising a forced-air system to draw the contaminated air through a green wall based on a soil-less growing medium containing activated carbon, the combined effects of substrate media and botanical component within the biofiltration system showed statistically significant VOC reduction, averaging 57% single-pass removal efficiency over multiple test procedures. These results indicate a high level of VOC removal efficiency for the active green wall biofilter tested and provide evidence that active biofiltration may aid in reducing exposure to VOCs in the indoor environment.

  6. Physical degradation of proteins in well-defined fluid flows studied within a four-roll apparatus.

    Science.gov (United States)

    Simon, S; Krause, H J; Weber, C; Peukert, W

    2011-12-01

    In most applications of biotechnology and downstream processing proteins are exposed to fluid stresses in various flow configurations which often lead to the formation of unwanted protein aggregates. In this paper we present physical degradation experiments for proteins under well-defined flow conditions in a four-roll apparatus. The flow field was characterized numerically by computational fluid dynamics (CFD) and experimentally by particle image velocimetry (PIV). The local shear strain rate as well as the local shear and elongation rate was used to characterize the hydrodynamic stress environment acting on the proteins. Lysozyme was used as a model protein and subjected to well-defined fluid stresses in high and low stress environment. By using in situ turbidity measurements during stressing the aggregate formation was monitored directly in the fluid flow. An increase in absorbance at 350 nm was attributed to a higher content of visible particles (>1 µm). In addition to lysozyme, the formation of aggregates was confirmed for two larger proteins (bovine serum albumin and alcohol dehydrogenase). Thus, the presented experimental setup is a helpful tool to monitor flow-induced protein aggregation with high reproducibility. For instance, screening experiments for formulation development of biopharmaceuticals for fill and finish operations can be performed in the lab-scale in a short time-period if the stress distributions in the application are transferred and applied in the four-roll mill. Copyright © 2011 Wiley Periodicals, Inc.

  7. [Intestinal absorption of different combinations of active compounds from Gegenqinlian decoction by rat single pass intestinal perfusion in situ].

    Science.gov (United States)

    An, Rui; Zhang, Hua; Zhang, Yi-Zhu; Xu, Ran-Chi; Wang, Xin-Hong

    2012-12-01

    The aim is to study the intestinal absorption of different combinations of active compounds out of Gegenqinlian decoction. Rat single pass intestinal perfusion model with jugular vein cannulated was used. Samples were obtained continuously from the outlet perfusate and the mesenteric vein. The levels of puerarin, daidzin, liquilitin, baicalin, wogonoside, jatrorrhizine, berberine and palmatine were determined by LC-MS/MS and their permeability coefficients were calculated. The results showed that Glycyrrhiza could promote the absorption of the active ingredients in Pueraria which is the monarch herb; meanwhile, Pueraria also played a role in promoting the absorption of liquilitin. Based on the Gegenqinlian decoction and the different combinations experiments, the results concerning the absorption of baicalin and wogonoside were as follows. For baicalin, Pueraria and Glycyrrhiza could promote its absorption and the effect of Pueraria was more obvious. For wogonoside, Pueraria could also promote its absorption, while Glycyrrhiza played a opposite role. Pueraria and Glycyrrhiza both played a part in promoting the absorption of jateorhizine, berberine and palmatine, the effective compounds in Coptis.

  8. Absorption characteristics of the total alkaloids from Mahonia bealei in an in situ single-pass intestinal perfusion assay.

    Science.gov (United States)

    Sun, Yu-He; He, Xin; Yang, Xiao-Lin; Dong, Cui-Lan; Zhang, Chun-Feng; Song, Zi-Jing; Lu, Ming-Xing; Yang, Zhong-Lin; Li, Ping

    2014-07-01

    To investigate the absorption characteristics of the total alkaloids from Mahoniae Caulis (TAMC) through the administration of monterpene absorption enhancers or protein inhibitors. The absorption behavior was investigated in an in situ single-pass intestinal perfusion (SPIP) assay in rats. The intestinal absorption of TAMC was much more than that of a single compound or a mixture of compounds (jatrorrhizine, palmatine, and berberine). Promotion of absorption by the bicyclic monoterpenoids (borneol or camphor) was higher than by the monocyclic monoterpenes (menthol or menthone), and promotion by compounds with a hydroxyl group (borneol or menthol) was higher than those with a carbonyl group (camphor or menthone). The apparent permeability coefficient (Papp) of TAMC was increased to 1.8-fold by verapamil, while it was reduced to one half by thiamine. The absorption rate constant (Ka) and Papp of TAMC were unchanged by probenecid and pantoprazole. The intestinal absorption characteristics of TAMC might be passive transport, and the intestinum tenue was the best absorptive site. In addition, TAMC might be likely a substrate of P-glycoprotein (P-gp) and organic cation transporters (OCT), rather than multidrug resistance protein (MRP) and breast cancer resistance protein (BCRP). Compared with a single compound and a mixture of compounds, TAMC was able to be absorbed in the blood circulation effectively. Copyright © 2014 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.

  9. Sea ice local surface topography from single-pass satellite InSAR measurements: a feasibility study

    Directory of Open Access Journals (Sweden)

    W. Dierking

    2017-08-01

    Full Text Available Quantitative parameters characterizing the sea ice surface topography are needed in geophysical investigations such as studies on atmosphere–ice interactions or sea ice mechanics. Recently, the use of space-borne single-pass interferometric synthetic aperture radar (InSAR for retrieving the ice surface topography has attracted notice among geophysicists. In this paper the potential of InSAR measurements is examined for several satellite configurations and radar frequencies, considering statistics of heights and widths of ice ridges as well as possible magnitudes of ice drift. It is shown that, theoretically, surface height variations can be retrieved with relative errors  ≤  0.5 m. In practice, however, the sea ice drift and open water leads may contribute significantly to the measured interferometric phase. Another essential factor is the dependence of the achievable interferometric baseline on the satellite orbit configurations. Possibilities to assess the influence of different factors on the measurement accuracy are demonstrated: signal-to-noise ratio, presence of a snow layer, and the penetration depth into the ice. Practical examples of sea surface height retrievals from bistatic SAR images collected during the TanDEM-X Science Phase are presented.

  10. {open_quotes}Optical guiding{close_quotes} limits on extraction efficiencies of single-pass, tapered wiggler amplifiers

    Energy Technology Data Exchange (ETDEWEB)

    Fawley, W.M. [Lawrence Berkeley Lab., CA (United States)

    1995-12-31

    Single-pass, tapered wiggler amplifiers have an attractive feature of being able, in theory at least, of extracting a large portion of the electron beam energy into light. In circumstances where an optical FEL`s wiggler length is significantly longer than the Rayleigh length Z{sub R} corresponding to the electron beam radius, diffraction losses must be controlled via the phenomenon of {open_quotes}optical guiding{close_quotes}. Since the strength of the guiding depends upon the effective refractive index {eta}{sub r} exceeding one, and since ({eta}{sub r}-1) is inversely proportional to the optical electric field, there is a natural {open_quotes}limiting{close_quotes} mechanism to the on-axis field strength and thus the rate at which energy may be extracted from the electron beam. In particular, the extraction efficiency for a prebunched beam asymptotically grows linearly with z rather than quadratically. We present analytical and numerical simulation results concerning this behavior and discuss its applicability to various FEL designs including oscillator/amplifier-radiator configurations.

  11. Single-Pass Percutaneous Liver Biopsy for Diffuse Liver Disease Using an Automated Device: Experience in 154 Procedures

    International Nuclear Information System (INIS)

    Rivera-Sanfeliz, Gerant; Kinney, Thomas B.; Rose, Steven C.; Agha, Ayad K.M.; Valji, Karim; Miller, Franklin J.; Roberts, Anne C.

    2005-01-01

    Purpose: To describe our experience with ultrasound (US)-guided percutaneous liver biopsies using the INRAD 18G Express core needle biopsy system.Methods: One hundred and fifty-four consecutive percutaneous core liver biopsy procedures were performed in 153 men in a single institution over 37 months. The medical charts, pathology reports, and radiology files were retrospectively reviewed. The number of needle passes, type of guidance, change in hematocrit level, and adequacy of specimens for histologic analysis were evaluated.Results: All biopsies were performed for histologic staging of chronic liver diseases. The majority of patients had hepatitis C (134/153, 90.2%). All patients were discharged to home after 4 hr of postprocedural observation. In 145 of 154 (94%) biopsies, a single needle pass was sufficient for diagnosis. US guidance was utilized in all but one of the procedures (153/154, 99.4%). The mean hematocrit decrease was 1.2% (44.1-42.9%). Pain requiring narcotic analgesia, the most frequent complication, occurred in 28 of 154 procedures (18.2%). No major complications occurred. The specimens were diagnostic in 152 of 154 procedures (98.7%).Conclusions: Single-pass percutaneous US-guided liver biopsy with the INRAD 18G Express core needle biopsy system is safe and provides definitive pathologic diagnosis of chronic liver disease. It can be performed on an outpatient basis. Routine post-biopsy monitoring of hematocrit level in stable, asymptomatic patients is probably not warranted

  12. A 3D Reconstruction Strategy of Vehicle Outline Based on Single-Pass Single-Polarization CSAR Data.

    Science.gov (United States)

    Leping Chen; Daoxiang An; Xiaotao Huang; Zhimin Zhou

    2017-11-01

    In the last few years, interest in circular synthetic aperture radar (CSAR) acquisitions has arisen as a consequence of the potential achievement of 3D reconstructions over 360° azimuth angle variation. In real-world scenarios, full 3D reconstructions of arbitrary targets need multi-pass data, which makes the processing complex, money-consuming, and time expending. In this paper, we propose a processing strategy for the 3D reconstruction of vehicle, which can avoid using multi-pass data by introducing a priori information of vehicle's shape. Besides, the proposed strategy just needs the single-pass single-polarization CSAR data to perform vehicle's 3D reconstruction, which makes the processing much more economic and efficient. First, an analysis of the distribution of attributed scattering centers from vehicle facet model is presented. And the analysis results show that a smooth and continuous basic outline of vehicle could be extracted from the peak curve of a noncoherent processing image. Second, the 3D location of vehicle roofline is inferred from layover with empirical insets of the basic outline. At last, the basic line and roofline of the vehicle are used to estimate the vehicle's 3D information and constitute the vehicle's 3D outline. The simulated and measured data processing results prove the correctness and effectiveness of our proposed strategy.

  13. Single-frequency blue light generation by single-pass sum-frequency generation in a coupled ring cavity tapered laser

    DEFF Research Database (Denmark)

    Jensen, Ole Bjarlin; Petersen, Paul Michael

    2013-01-01

    A generic approach for generation of tunable single frequency light is presented. 340 mW of near diffraction limited, single-frequency, and tunable blue light around 459 nm is generated by sum-frequency generation (SFG) between two tunable tapered diode lasers. One diode laser is operated in a ring...... cavity and another tapered diode laser is single-passed through a nonlinear crystal which is contained in the coupled ring cavity. Using this method, the single-pass conversion efficiency is more than 25%. In contrast to SFG in an external cavity, the system is entirely self-stabilized with no electronic...

  14. Spin coating apparatus

    Science.gov (United States)

    Torczynski, John R.

    2000-01-01

    A spin coating apparatus requires less cleanroom air flow than prior spin coating apparatus to minimize cleanroom contamination. A shaped exhaust duct from the spin coater maintains process quality while requiring reduced cleanroom air flow. The exhaust duct can decrease in cross section as it extends from the wafer, minimizing eddy formation. The exhaust duct can conform to entrainment streamlines to minimize eddy formation and reduce interprocess contamination at minimal cleanroom air flow rates.

  15. Flowing afterglow: construction of an apparatus, measurement of rate constants, and consideration of the diffusive behavior of charges

    International Nuclear Information System (INIS)

    Matsuoka, Shingo; Nakamura, Hirone; Tamura, Takaaki; Fujii, Toshihiro.

    1984-01-01

    A flowing afterglow apparatus was constructed and the operation of the afterglow system including data analysis was tested by measuring the rate constants for the reactions N + + NO, N 2 + + NO, He + + N 2 , and SF 6 + e; the results were 5.8 x 10 -10 , 3.9 x 10 -10 , 1.20 x 10 -9 , and 2.1 x 10 -7 cm 3 s -1 respectively. In the measurements an extraction voltage for ion sampling was not applied to the nose cone in order not to introduce an electric field into the reaction region. A ''non-ambipolar'' model developed by us was used for the data analysis of the ion/molecule reactions. For the data analysis of the electron attachment, a typical curve fit mehtod to the product ion signal was used. However, no theoretical curves fit the experimental points. This disagreement is attributed to a change of the ion-sampling efficiency through the nose-cone aperture arising from a change of the electron-dominated plasma to a negative-ion-dominated plasma with an increasing flow rate of SF 6 . Nevertheless, the attachment rate could be determined by fitting the theoretical and experimantal curves in the limited region of the SF 6 flow rate where the negative-ion-dominated plasma is established at the sampling aperture. All the rate constants obtained here agree reasonably well with literature values. Next, errors in the positive ion/molecule reaction rate constants, which would occur if the diffusion coefficients of the ions and neutrals each have a + 10 % error were calculated for the flow model to be -0.4 and +1.2 % respectively, demonstrating that these parameters are not important in the analysis of data. This insensitivity explains why the nose-cone voltage applied in a typical flowing afterglow operation has not caused a significant error in the published rate constants although it disturbs the ion diffusive behavior. (author)

  16. Balancing Radiation and Contrast Media Dose in Single-Pass Abdominal Multidetector CT: Prospective Evaluation of Image Quality.

    Science.gov (United States)

    Camera, Luigi; Romano, Federica; Liccardo, Immacolata; Liuzzi, Raffaele; Imbriaco, Massimo; Mainenti, Pier Paolo; Pizzuti, Laura Micol; Segreto, Sabrina; Maurea, Simone; Brunetti, Arturo

    2015-11-01

    As both contrast and radiation dose affect the quality of CT images, a constant image quality in abdominal contrast-enhanced multidetector computed tomography (CE-MDCT) could be obtained balancing radiation and contrast media dose according to the age of the patients. Seventy-two (38 Men; 34 women; aged 20-83 years) patients underwent a single-pass abdominal CE-MDCT. Patients were divided into three different age groups: A (20-44 years); B (45-65 years); and C (>65 years). For each group, a different noise index (NI) and contrast media dose (370 mgI/mL) was selected as follows: A (NI, 15; 2.5 mL/kg), B (NI, 12.5; 2 mL/kg), and C (NI, 10; 1.5 mL/kg). Radiation exposure was reported as dose-length product (DLP) in mGy × cm. For quantitative analysis, signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were calculated for both the liver (L) and the abdominal aorta (A). Statistical analysis was performed with a one-way analysis of variance. Standard imaging criteria were used for qualitative analysis. Although peak hepatic enhancement was 152 ± 16, 128 ± 12, and 101 ± 14 Hounsfield units (P contrast media dose (mL) administered were 476 ± 147 and 155 ± 27 for group A, 926 ± 291 and 130 ± 16 for group B, and 1981 ± 451 and 106 ± 15 for group C, respectively (P contrast media dose administered to patients of different age. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  17. Single-pass Airborne InSAR for Wide-swath, High-Resolution Cryospheric Surface Topography Mapping

    Science.gov (United States)

    Moller, D.; Hensley, S.; Wu, X.; Muellerschoen, R.

    2014-12-01

    In May 2009 a mm-wave single-pass interferometric synthetic aperture radar (InSAR) for the first time demonstrated ice surface topography swath-mapping in Greenland. This was achieved with the airborne Glacier and Ice Surface Topography Interferometer (GLISTIN-A). Ka-band (35.6GHz) was chosen for high-precision topographic mapping from a compact sensor with minimal surface penetration. In recent years, the system was comprehensively upgraded for improved performance, stability and calibration. In April 2013, after completing the upgrades, GLISTIN-A flew a brief campaign to Alaska. The primary purpose was to demonstrate the InSAR's ability to generate high-precision, high resolution maps of ice surface topography with swaths in excess of 10km. Comparison of GLISTIN-A's elevations over glacial ice with lidar verified the precision requirements and established elevation accuracies to within 2 m without tie points. Feature tracking of crevasses on Columbia Glacier using data acquired with a 3-day separation exhibit an impressive velocity mapping capability. Furthermore, GLISTIN-A flew over the Beaufort sea to determine if we could not only map sea ice, but also measure freeboard. Initial analysis has established we can measure sea-ice freeboard using height differences from the top of the sea-ice and the sea surface in open leads. In the future, a campaign with lidar is desired for a quantitative validation. Another proof-of-concept collection mapped snow-basins for hydrology. Snow depth measurements using summer and winter collections in the Sierras were compared with lidar measurements. Unsurprisingly when present, trees complicate the interpretation, but additional filtering and processing is in work. For each application, knowledge of the interferometric penetration is important for scientific interpretation. We present analytical predictions and experimental data to upper bound the elevation bias of the InSAR measurements over snow and snow-covered ice.

  18. Nuclear core baffling apparatus

    International Nuclear Information System (INIS)

    Cooper, F.W. Jr.; Silverblatt, B.L.; Knight, C.B.; Berringer, R.T.

    1979-01-01

    An apparatus for baffling the flow of reactor coolant fluid into and about the core of a nuclear reactor is described. The apparatus includes a plurality of longitudinally aligned baffle plates with mating surfaces that allow longitudinal growth with temperature increases while alleviating both leakage through the aligned plates and stresses on the components supporting the plates

  19. Double Pass 595?nm pulsed dye laser at a 6 minute interval for the treatment of port-wine stains is not more effective than single pass

    NARCIS (Netherlands)

    Peters, M. A. D.; van Drooge, A. M.; Wolkerstorfer, A.; van Gemert, M. J. C.; van der Veen, J. P. W.; Bos, J. D.; Beek, J. F.

    2012-01-01

    Background Pulsed dye laser (PDL) is the first choice for treatment of port wine stains (PWS). However, outcome is highly variable and only a few patients achieve complete clearance. The objective of the study was to compare efficacy and safety of single pass PDL with double pass PDL at a 6 minute

  20. An advanced EPR stopped-flow apparatus based on a dielectric ring resonator

    Science.gov (United States)

    Lassmann, Günter; Schmidt, Peter Paul; Lubitz, Wolfgang

    2005-02-01

    A novel EPR stopped-flow accessory is described which allows time-dependent cw-EPR measurements of rate constants of reactions involving paramagnetic species after rapid mixing of two liquid reagents. The EPR stopped-flow design represents a state-of-the-art, computer controlled fluid driving system, a miniresonant EPR structure with an integrated small ball mixer, and a stopping valve. The X-band EPR detection system is an improved version of that reported by Sienkiewicz et al. [Rev. Sci. Instr. 65 (1994) 68], and utilizes a resonator with two stacked ceramic dielectric rings separated by a variable spacer. The resonator with the mode TE( H) 011 is tailored particularly for conditions of fast flowing and rapidly stopped aqueous solutions, and for a high time resolution. The short distance between the ball mixer and the small EPR active volume (1.8 μl) yields a measured dead time of 330 μs. A compact assembly of all parts results in minimization of disturbing microphonics. The computer controlled driving system from BioLogic with two independent stepping motors was optimized for EPR stopped-flow with a hard-stop valve. Performance tests on the EPR spectrometer ESP 300E from BRUKER using redox reactions of nitroxide radicals revealed the EPR stopped-flow accessory as an advanced, versatile, and reliable instrument with high reproducibility.

  1. Method and apparatus for improved melt flow during continuous strip casting

    Science.gov (United States)

    Follstaedt, Donald W.; King, Edward L.; Schneider, Ken C.

    1991-11-12

    The continuous casting of metal strip using the melt overflow process is improved by controlling the weir conditions in the nozzle to provide a more uniform flow of molten metal across the width of the nozzle and reducing the tendency for freezing of metal along the interface with refractory surfaces. A weir design having a sloped rear wall and tapered sidewalls and critical gap controls beneath the weir has resulted in the drastic reduction in edge tearing and a significant improvement in strip uniformity. The floor of the container vessel is preferably sloped and the gap between the nozzle and the rotating substrate is critically controlled. The resulting flow patterns observed with the improved casting process have reduced thermal gradients in the bath, contained surface slag and eliminated undesirable solidification near the discharge area by increasing the flow rates at those points.

  2. Sensor chip and apparatus for tactile and/or flow sensing

    Science.gov (United States)

    Liu, Chang (Inventor); Chen, Jack (Inventor); Engel, Jonathan (Inventor)

    2009-01-01

    A sensor chip, comprising a flexible, polymer-based substrate, and at least one microfabricated sensor disposed on the substrate and including a conductive element. The at least one sensor comprises at least one of a tactile sensor and a flow sensor. Other embodiments of the present invention include sensors and/or multi-modal sensor nodes.

  3. Method of an apparatus for analysing gas flows inside hollow bodies

    International Nuclear Information System (INIS)

    Stewart, P.A.E.

    1981-01-01

    In order to produce a visual image on a screen of the movement of gas flows inside hollow bodies, e.g. gas turbine or internal combustion engines, or wind tunnels, a gaseous tracer material including a short-lived radio-active isotope is injected into the hollow body. One suitable isotope is produced by irradiating carbon tetrafluoride using a stream of deuterons from a cyclotron. The resulting reaction produces an isotope of Fluorine which has a half-life of 11.56 seconds, and decays producing radiation at approximately 1.6 Mev. The activity of the isotope is raised to the highest feasible level by continually irradiating the tracer material in a chamber as it is pumped around a circuit prior to injection. The half lives of the isotopes used are in the range 3 seconds to 2 minutes. (author)

  4. Atrial electrogram quality in single-pass defibrillator leads with floating atrial bipole in patients with permanent atrial fibrillation and cardiac resynchronization therapy.

    Science.gov (United States)

    Sticherling, Christian; Müller, Dirk; Schaer, Beat A; Krüger, Silke; Kolb, Christof

    2018-03-27

    Many patients receiving cardiac resynchronization therapy (CRT) suffer from permanent atrial fibrillation (AF). Knowledge of the atrial rhythm is important to direct pharmacological or interventional treatment as well as maintaining AV-synchronous biventricular pacing if sinus rhythm can be restored. A single pass single-coil defibrillator lead with a floating atrial bipole has been shown to obtain reliable information about the atrial rhythm but has never been employed in a CRT-system. The purpose of this study was to assess the feasibility of implanting a single coil right ventricular ICD lead with a floating atrial bipole and the signal quality of atrial electrograms (AEGM) in CRT-defibrillator recipients with permanent AF. Seventeen patients (16 males, mean age 73 ± 6 years, mean EF 25 ± 5%) with permanent AF and an indication for CRT-defibrillator placement were implanted with a designated CRT-D system comprising a single pass defibrillator lead with a atrial floating bipole. They were followed-up for 103 ± 22 days using remote monitoring for AEGM transmission. All patients had at last one AEGM suitable for atrial rhythm diagnosis and of 100 AEGM 99% were suitable for visual atrial rhythm assessment. Four patients were discharged in sinus rhythm and one reverted to AF during follow-up. Atrial electrograms retrieved from a single-pass defibrillator lead with a floating atrial bipole can be reliably used for atrial rhythm diagnosis in CRT recipients with permanent AF. Hence, a single pass ventricular defibrillator lead with a floating bipole can be considered in this population. Copyright © 2018 Indian Heart Rhythm Society. Production and hosting by Elsevier B.V. All rights reserved.

  5. Simultaneous release of diclofenac sodium and papaverine hydrochloride from tablets and pellets using the flow-through cell apparatus described by dimensionless equations.

    Science.gov (United States)

    Kasperek, Regina

    2011-01-01

    The release of diclofenac sodium and papaverine hydrochloride from tablets and pellets using the flow-through cell apparatus was studied. The influence of excipients and of a size of the solid dosage forms on the amount of the released substances at the intervals of time using the different rates of flow of the dissolution medium was investigated. Physical parameters corresponding to the dissolution process as the mass transfer coefficient, the thickness of the boundary diffusion layer and the concentration of the saturated solution at this layer were calculated. The results of release were described by dimensionless equations.

  6. Membrane flow in plants: Fractionation of growing pollen tubes of tobacco by preparative free-flow electrophoresis and kinetics of labeling of endoplasmic reticulum and Golgi apparatus with (/sup 3/H)leucine

    Energy Technology Data Exchange (ETDEWEB)

    Kappler, R.; Kristen, U.; Morre, D.J.

    1986-01-01

    Tobacco (Nicotiana tabacum L.) pollen, germinated 4 hours in suspension culture,was labeled with radioactive leucine and fractionated into constituent membranes by the technique of preparative free-flow electrophoresis. Tubes were ruptured by sonication directly into the electrophoresis buffer. Unfortunately, the Golgi apparatus of the rapidly elongating pollen tubes did not survive the sonication step. However, it was possible to obtain useful fractions of endoplasmic reticulum and mitochondria. To obtain Golgi apparatus, glutaraldehyde was added to the homogenization buffer during sonication. Plasma membrane, which accounted for only about 3% of the total membrane of the homogenates as determined by staining with phosphotungstate at low pH, was obtained in insufficient quantity and fraction purity to permit analysis. Results show rapid incorporation of (/sup 3/H)leucine into endoplasmic reticulum followed by rapid chase out. The half-time for loss of radioactivity from the pollen tube endoplasmic reticulum was about 10 minutes. Concomitant with the loss of radioactivity from endoplasmic reticulum, the Golgi apparatus fraction was labeled reaching a maximum 20 minutes post chase. The findings suggest flow of membranes from endoplasmic reticulum to the Golgi apparatus during pollen tube growth.

  7. Absorption Properties of Luteolin and Apigenin in Genkwa Flos Using In Situ Single-Pass Intestinal Perfusion System in the Rat.

    Science.gov (United States)

    He, Xin; Song, Zi-Jing; Jiang, Cui-Ping; Zhang, Chun-Feng

    2017-01-01

    The flower bud of Daphne genkwa (Genkwa Flos) is a commonly used herbal medicine in Asian countries. Luteolin and apigenin are two recognized active flavonoids in Genkwa Flos. The aim of this study was to investigate the intestinal absorption mechanisms of Genkwa Flos flavonoids using in situ single-pass intestinal perfusion rat model. Using HPLC, we determined its major effective flavonoids luteolin, apigenin, as well as, hydroxygenkwanin and genkwanin in biological samples. The intestinal absorption mechanisms of the total flavonoids in Genkwa Flos (TFG) were investigated using in situ single-pass intestinal perfusion rat model. Comparing the TFG absorption rate in different intestinal segments, data showed that the small intestine absorption was significantly higher than that of the colon ([Formula: see text]). Compared with duodenum and ileum, the jejunum was the best small intestinal site for TFG absorption. The high TFG concentration (61.48[Formula: see text][Formula: see text]g/ml) yielded the highest permeability ([Formula: see text]). Subsequently, three membrane protein inhibitors (verapamil, pantoprazole and probenecid) were used to explore the TFG absorption pathways. Data showed probenecid, a multidrug resistance protein (or MRP) inhibitor, effectively enhanced the TFG absorption ([Formula: see text]). Furthermore, by comparing commonly used natural absorption enhancers on TFG, it was observed that camphor was the most effective. In Situ single-pass intestinal perfusion experiment shows that TFG absorption is much higher in the small intestine than in the colon, and the TFG is absorbed mainly via an active transport pathway with MRP-mediated efflux mechanism. Camphor obviously enhanced the TFG absorption, and this could be an effective TFG formulation preparation method to increase clinical effectiveness after Genkwa Flos administration. Our study elucidated the TFG absorption mechanisms, and provided new information for its formulation preparation.

  8. THE CONTROL ALGORITHM OF THE DRYING PROCESS PARTICULATE MATERIALS IN THE APPARATUS WITH THE SWIRLING FLOW OF COOLANT AND MICROWAVE ENERGY SUPPLY

    Directory of Open Access Journals (Sweden)

    S. T. Antipov

    2015-01-01

    Full Text Available The technical task of the process is to improve the drying quality of the final product, increasing the precision and reliability of control, the reduction of specific energy consumption. One of the ways to improve the process is complex and i ts local automation. This paper deals with the problems of development and creation of a new control algorithm drying process of the particulate material. Identified a number of shortcomings of the existing methods of automatic control of the process. As a result, the authors proposed a method for drying particulate materials in the device with swirling flow and the microwave energy supply and its automatic control algorithm. The description of the operating principle of the drying apparatus consists in that the particulate material is wet by using a tangential flow of coolant supplied to the cylinder-drying apparatus which also serves the axial coolant flow, whereby the heat transfer fluid with the particulate material begins to undergo a complex circular movement along the circumference apparatus, thereby increasing its speed and its operation control algorithm. The work of this scheme is carried out at three levels of regulation on the basis of determining the coefficient of efficiency of the dryer, which makes it possible to determine the optimal value of the power equipment and to forecast the cost of electricity. All of the above allows you to get ready for a high quality product while minimizing thermal energy and material costs by optimizing the operating parameters of the drying of the particulate material in the dryer with a combined microwave energy supply and ensure the rational use of heat energy by varying their quantity depending on the characteristics to be dried particulate material and the course of the process.

  9. A Unified Algorithm for Channel Imbalance and Antenna Phase Center Position Calibration of a Single-Pass Multi-Baseline TomoSAR System

    Directory of Open Access Journals (Sweden)

    Yuncheng Bu

    2018-03-01

    Full Text Available The multi-baseline synthetic aperture radar (SAR tomography (TomoSAR system is employed in such applications as disaster remote sensing, urban 3-D reconstruction, and forest carbon storage estimation. This is because of its 3-D imaging capability in a single-pass platform. However, a high 3-D resolution of TomoSAR is based on the premise that the channel imbalance and antenna phase center (APC position are precisely known. If this is not the case, the 3-D resolution performance will be seriously degraded. In this paper, a unified algorithm for channel imbalance and APC position calibration of a single-pass multi-baseline TomoSAR system is proposed. Based on the maximum likelihood method, as well as the least squares and the damped Newton method, we can calibrate the channel imbalance and APC position. The algorithm is suitable for near-field conditions, and no phase unwrapping operation is required. The effectiveness of the proposed algorithm has been verified by simulation and experimental results.

  10. Investigating drug absorption from the colon: Single-pass vs. Doluisio approaches to in-situ rat large-intestinal perfusion.

    Science.gov (United States)

    Lozoya-Agullo, Isabel; Zur, Moran; Fine-Shamir, Noa; Markovic, Milica; Cohen, Yael; Porat, Daniel; González-Álvarez, Isabel; González-Álvarez, Marta; Merino-Sanjuán, Matilde; Bermejo, Marival; Dahan, Arik

    2017-07-15

    Traditionally, the colon is considered a secondary intestinal segment in the drug absorption process. However, in many cases the role of colonic drug permeability cannot be overlooked. The purpose of this research was to compare colon permeability data obtained using two different rat perfusion methods the single-pass intestinal perfusion (SPIP) approach and the closed-loop (Doluisio) perfusion model. A list of 14 structurally diverse model drugs was constructed, and their rat colon permeability was studied using the two methods. The two sets of results were compared to each other, and were evaluated vs. in-vitro, ex-vivo, and in-vivo literature values. The SPIP and the Doluisio results exhibited good correlation between them (R 2 =0.81). The best correlation of both sets was obtained with transport studies across Caco-2 monolayers (R 2 ∼0.9), as well as the sigmoidal fit vs. human fraction of dose absorbed (F abs ) data. On the other hand, Ussing chambers data, as well as lipophilicity (Log P) data, resulted in weak correlation to the in-situ results. In conclusion, the single-pass intestinal perfusion (SPIP) and the Doluisio (closed-loop) perfusion models were found to be equally convenient and useful for obtaining validated colon permeability values, although more human colonic F abs data are needed for a better understanding of colonic drug permeability and absorption. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Pump apparatus including deconsolidator

    Energy Technology Data Exchange (ETDEWEB)

    Sonwane, Chandrashekhar; Saunders, Timothy; Fitzsimmons, Mark Andrew

    2014-10-07

    A pump apparatus includes a particulate pump that defines a passage that extends from an inlet to an outlet. A duct is in flow communication with the outlet. The duct includes a deconsolidator configured to fragment particle agglomerates received from the passage.

  12. Pyrolysis process and apparatus

    Science.gov (United States)

    Lee, Chang-Kuei

    1983-01-01

    This invention discloses a process and apparatus for pyrolyzing particulate coal by heating with a particulate solid heating media in a transport reactor. The invention tends to dampen fluctuations in the flow of heating media upstream of the pyrolysis zone, and by so doing forms a substantially continuous and substantially uniform annular column of heating media flowing downwardly along the inside diameter of the reactor. The invention is particularly useful for bituminous or agglomerative type coals.

  13. Ultrasonic drilling apparatus

    Science.gov (United States)

    Duran, E.L.; Lundin, R.L.

    1988-06-20

    Apparatus attachable to an ultrasonic drilling machine for drilling deep holes in very hard materials, such as boron carbide, is provided. The apparatus utilizes a hollow spindle attached to the output horn of the ultrasonic drilling machine. The spindle has a hollow drill bit attached at the opposite end. A housing surrounds the spindle, forming a cavity for holding slurry. In operation, slurry is provided into the housing, and into the spindle through inlets while the spindle is rotating and ultrasonically reciprocating. Slurry flows through the spindle and through the hollow drill bit to cleanse the cutting edge of the bit during a drilling operation. 3 figs.

  14. Single Pass Optical Profile Monitoring

    CERN Document Server

    Jung, R; Hutchins, Stephen

    2003-01-01

    Beam profiles are acquired in transfer lines to monitor extracted beams and compute their emittance. Measurements performed on the first revolutions of a ring will evaluate the matching of a chain of accelerators. Depending on the particle type and energy, these measurements are in general performed with screens, making either use of Luminescence or Optical Transition Radiation [OTR], and the generated beam images are acquired with sensors of various types. Sometimes the beam position is also measured this way. The principle, advantages and disadvantages of both families of screens will be discussed in relation with the detectors used. Test results with beam and a possible evaluation method for luminescent screens will be presented. Finally other optical methods used will be mentioned for completeness.

  15. The design of a prototype system which controls the flow of milk in the collector’s column of an autonomous milking apparatus

    Directory of Open Access Journals (Sweden)

    Lis Stanisław

    2018-01-01

    Full Text Available The research paper presents a prototype system controlling the flow of milk in the collection column of an autonomous milking apparatus. In the Matlab®-Simulink program, the simulation model of such a system was created. Its essential operation is illustrated in the block diagrams. The logic verification of the model’s operational accuracy (off-line simulation did not reveal errors. Therefore a laboratory stand for hardware verification – (on-line simulation was developed. Within it a virtual feedback loop of the control system (stored in computer memory, with elements of real object control incorporated – in this way a prototype of the device was created. During the hardware verification of the proposed technical solution, operation errors were not observed. In response to certain signals from the measuring elements, the controller correctly calculated control signals for the actuators.

  16. Method and apparatus for monitoring fluid flow between a borehole and the surrounding formations in the course of drilling operations

    Energy Technology Data Exchange (ETDEWEB)

    Evans, J. L.; Gehrig, G. F.; Speers, J. M.

    1985-11-19

    A method and apparatus for establishing the rate at which fluid is transferred between a borehole and the surrounding formations in the course of moving drill string upward or downward in the borehole. A bell nipple is situated at the upper portion of the borehole. While tripping, drilling fluid is circulated into the borehole and exits through an outflow port in the bell nipple. The level of drilling fluid is maintained constant at the outflow port. Meters are provided to measure inflow and outflow rates. Circuitry is provided to establish the volume rate at which the amount of drill string within the borehole changes. The outputs of the meters and rate establishing means are summed to establish the compensated rate at which fluid is transferred between the formations and the borehole. This compensated rate is compared to an alarm limit. An alarm is activated if the compensated rate exceeds the alarm limit.

  17. CRADA with Beckman Instruments and Pacific Northwest National Laboratory (PNL-013): Development and commercialization of the Unsaturated Flow Apparatus (UFA) using characterization of aridisols

    Energy Technology Data Exchange (ETDEWEB)

    Wright, J.; Conca, J.

    1996-10-01

    The objective of this Cooperative Research and Development Agreement (CRADA) was to develop and commercialize a technology conceived by scientists at Pacific Northwest National Laboratory (PNNL) and manufactured by Beckman Instruments, Inc. (Beckman), and to apply this technology to the characterization of and soils. The technology is the Unsaturated Flow Apparatus (UFA). The UFA provides a highly efficient method of direct, rapid measurement of hydraulic conductivity and other flow properties according to Darcy-Buckingham principles because the operator controls both the fluid driving force, using an ultracentrifuge, and the flow into the sample while it is spinning, with a rotating seal assembly. The concept of using centrifugation to significantly decrease the time needed, from years or months to days, for study of subsurface transport, particularly under unsaturated conditions, was conceived by James Conca, Ph.D., and Judith Wright, Ph.D., in 1986. The prototype UFA was developed in 1988 because there was a need to rapidly and accurately determine transport parameters in soils, sediments, and rocks for the Grout Waste Disposal Program. Transport parameters are critical to modeling outcomes for site-specific solutions to environmental remediation and waste disposal problems.

  18. Isotope separation apparatus

    International Nuclear Information System (INIS)

    Lyon, R.K.; Eisner, P.N.; Thomas, W.R.I.

    1983-01-01

    This application discloses a method for and an apparatus in which isotopes of an element in a compared are separated from each other while that compound, i.e., including a mixture of such isotopes, flows along a predetermined path. The apparatus includes a flow tube having a beginning and an end. The mixture of isotopes is introduced into the flow tube at a first introduction point between the beginning and the end thereof to flow the mixture toward the end thereof. A laser irradiates the flow tube dissociating compounds of a preselected one of said isotopes thereby converting the mixture in an isotopically selective manner. The dissociation products are removed from the tube at a first removal point between the first introduction point and the end. The dissociation product removed at the the first removal point are reconverted back into the comound thereby providing a first stage enriched compound. This first stage enriched compound is reintroduced into the flow tube at a second introduction point between the beginning thereof and the first introduction point. Further product is removed from the flow tube at a second removal point between the second introduction point and the first introduction point. The second introduction point is chosen so that the isotope composition of the first stage enriched compound is approximately the same as that of the compound in the flow tube

  19. Gas cleaning apparatus

    International Nuclear Information System (INIS)

    Wakerley, M.W.; Asquith, R.W.; Kearney, A.S.; Pratt, R.P.

    1982-01-01

    Apparatus for removing radioactive constituents from a gas flow comprises a cartridge containing iodine absorber and movable from the left-hand position into which it is inserted past a door to the right-hand position where a jacking mechanism lifts it into flow communication with gas inlet and outlet ducts. Double lid systems each comprise one lid closing the cartridge port and another closing the corresponding port leading to the duct. The lids are engaged and lifted when the cartridge is in place, to open the flow paths, and subsequently lowered and disengaged when the cartridge is to be replaced. (author)

  20. Training apparatus

    International Nuclear Information System (INIS)

    Monteith, W.D.

    1983-01-01

    Training apparatus for use in contamination surveillance uses a mathematical model of a hypothetical contamination source (e.g. nuclear, bacteriological or chemical explosion or leak) to determine from input data defining the contamination source, the contamination level at any location within a defined exercise area. The contamination level to be displayed by the apparatus is corrected to real time from a real time clock or may be displayed in response to a time input from a keyboard. In a preferred embodiment the location is defined by entering UTM grid reference coordinates using the keyboard. The mathematical model used by a microprocessor of the apparatus for simulation of contamination levels in the event of a nuclear explosion is described. (author)

  1. Absorption characteristic of paeoniflorin-6'-O-benzene sulfonate (CP-25) in in situ single-pass intestinal perfusion in rats.

    Science.gov (United States)

    Yang, Xiao-Dan; Wang, Chun; Zhou, Peng; Yu, Jun; Asenso, James; Ma, Yong; Wei, Wei

    2016-09-01

    1. Paeoniflorin-6'-O-benzene sulfonate (CP-25) was synthesized to improve the poor oral absorption of paeoniflorin (Pae). 2. This study was performed to investigate the absorptive behavior and mechanism of CP-25 in in situ single-pass intestinal perfusion in rats, using Pae as a control. 3. The results showed that intestinal absorption of CP-25 was neither segmental nor sex dependent. However, the main segment of intestine that absorbed Pae was the duodenum. Furthermore, passive transport was confirmed to be the main absorption pattern of CP-25. More importantly, the absorption of CP-25 was much higher than Pae in the small intestine. 4. Among the ABC transporter inhibitors, the absorption rate of Pae increased in the presence of P-gp inhibitors verapamil and GF120918, which indicated that Pae was a substrate of P-glycoprotein (P-gp), however, such was not observed in the presence of breast cancer resistance protein and multidrug resistance-associated protein 2. Finally, the ABC transporter inhibitors did not have any significant impact on CP-25 as demonstrated in the parallel studies. 5. CP-25 could improve the poor absorption of Pae, which may be attributed to both the lipid solubility enhancement and its resistance to P-gp-mediated efflux.

  2. Double Pass 595 nm Pulsed Dye Laser Does Not Enhance the Efficacy of Port Wine Stains Compared with Single Pass: A Randomized Comparison with Histological Examination.

    Science.gov (United States)

    Yu, Wenxin; Zhu, Jiafang; Wang, Lizhen; Qiu, Yajing; Chen, Yijie; Yang, Xi; Chang, Lei; Ma, Gang; Lin, Xiaoxi

    2018-03-27

    To compare the efficacy and safety of double-pass pulsed dye laser (DWL) and single-pass PDL (SWL) in treating virgin port wine stain (PWS). The increase in the extent of vascular damage attributed to the use of double-pass techniques for PWS remains inconclusive. A prospective, side-by-side comparison with a histological study for virgin PWS is still lacking. Twenty-one patients (11 flat PWS, 10 hypertrophic PWS) with untreated PWS underwent 3 treatments at 2-month intervals. Each PWS was divided into three treatment sites: SWL, DWL, and untreated control. Chromametric and visual evaluation of the efficacy and evaluation of side effects were conducted 3 months after final treatment. Biopsies were taken at the treated sites immediately posttreatment. Chromametric and visual evaluation suggested that DWL sites showed no significant improvement compared with SWL (p > 0.05) in treating PWS. The mean depth of photothermal damage to the vessels was limited to a maximum of 0.36-0.41 mm in both SWL and DWL sides. Permanent side effects were not observed in any patients. Double-pass PDL does not enhance PWS clearance. To improve the clearance of PWS lesions, either the depth of laser penetration should be increased or greater photothermal damage to vessels should be generated.

  3. High-resolution digital elevation models from single-pass TanDEM-X interferometry over mountainous regions: A case study of Inylchek Glacier, Central Asia

    Science.gov (United States)

    Neelmeijer, Julia; Motagh, Mahdi; Bookhagen, Bodo

    2017-08-01

    This study demonstrates the potential of using single-pass TanDEM-X (TDX) radar imagery to analyse inter- and intra-annual glacier changes in mountainous terrain. Based on SAR images acquired in February 2012, March 2013 and November 2013 over the Inylchek Glacier, Kyrgyzstan, we discuss in detail the processing steps required to generate three reliable digital elevation models (DEMs) with a spatial resolution of 10 m that can be used for glacial mass balance studies. We describe the interferometric processing steps and the influence of a priori elevation information that is required to model long-wavelength topographic effects. We also focus on DEM alignment to allow optimal DEM comparisons and on the effects of radar signal penetration on ice and snow surface elevations. We finally compare glacier elevation changes between the three TDX DEMs and the C-band shuttle radar topography mission (SRTM) DEM from February 2000. We introduce a new approach for glacier elevation change calculations that depends on the elevation and slope of the terrain. We highlight the superior quality of the TDX DEMs compared to the SRTM DEM, describe remaining DEM uncertainties and discuss the limitations that arise due to the side-looking nature of the radar sensor.

  4. Segmental-dependent membrane permeability along the intestine following oral drug administration: Evaluation of a triple single-pass intestinal perfusion (TSPIP) approach in the rat.

    Science.gov (United States)

    Dahan, Arik; West, Brady T; Amidon, Gordon L

    2009-02-15

    In this paper we evaluate a modified approach to the traditional single-pass intestinal perfusion (SPIP) rat model in investigating segmental-dependent permeability along the intestine following oral drug administration. Whereas in the traditional model one single segment of the intestine is perfused, we have simultaneously perfused three individual segments of each rat intestine: proximal jejunum, mid-small intestine and distal ileum, enabling to obtain tripled data from each rat compared to the traditional model. Three drugs, with different permeabilities, were utilized to evaluate the model: metoprolol, propranolol and cimetidine. Data was evaluated in comparison to the traditional method. Metoprolol and propranolol showed similar P(eff) values in the modified model in all segments. Segmental-dependent permeability was obtained for cimetidine, with lower P(eff) in the distal parts. Similar P(eff) values for all drugs were obtained in the traditional method, illustrating that the modified model is as accurate as the traditional, throughout a wide range of permeability characteristics, whether the permeability is constant or segment-dependent along the intestine. Three-fold higher statistical power to detect segmental-dependency was obtained in the modified approach, as each subject serves as his own control. In conclusion, the Triple SPIP model can reduce the number of animals utilized in segmental-dependent permeability research without compromising the quality of the data obtained.

  5. Radiography apparatus

    International Nuclear Information System (INIS)

    Sashin, D.; Sternglass, E.J.

    1982-01-01

    The apparatus of the present invention provides radiography apparatus wherein the use of a flat, generally rectangular beam or a fan-shaped beam of radiation in combination with a collimator, scintillator and device for optically coupling a self-scanning array of photodiodes to the scintillator means will permit production of images or image data with high contrast sensitivity and detail. It is contemplated that the self-scanning array of photodiodes may contain from about 60 to 2048, and preferably about 256 to 2048, individual photodiode elements per inch of object width, thereby permitting maximum data collection to produce a complete image or complete collection of image data

  6. Radiotherapy apparatus

    International Nuclear Information System (INIS)

    Leung, P.M.; Webb, H.P.J.

    1985-01-01

    This invention relates to apparatus for applying intracavitary radiotherapy. In previously-known systems radioactive material is conveyed to a desired location within a patient by transporting a chain of balls pneumatically to and from an appropriately inserted applicator. According to this invention a ball chain for such a purpose comprises several radioactive balls separated by non-radioactive tracer balls of radiographically transparent material of lower density and surface hardness than the radioactive balls. The invention also extends to radiotherapy treatment apparatus comprising a storage, sorting and assembly system

  7. Radioimmunoassay apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Apparatus for performing a quantitative radioimmunoassay comprising: a substantially spherical bead for carrying an antibody and a gripper for gripping said bead, said gripper comprising an integrally formed unit having a single elongate handle portion and a plurality of resilient fingers arranged at the base of the handle so that when said bead is secured within said fingers, said bead may be freely rotated about any diametric axis of the bead. In particular the invention relates to an apparatus for a two site immunoradiometric assay for serum ferritin in human blood samples. (author)

  8. Waste Water Treatment Apparatus and Methods

    Science.gov (United States)

    Littman, Howard (Inventor); Plawsky, Joel L. (Inventor); Paccione, John D. (Inventor)

    2014-01-01

    An improved draft tube spout fluid bed (DTSFB) mixing, handling, conveying, and treating apparatus and systems, and methods for operating are provided. The apparatus and systems can accept particulate material and pneumatically or hydraulically conveying the material to mix and/or treat the material. In addition to conveying apparatus, a collection and separation apparatus adapted to receive the conveyed particulate material is also provided. The collection apparatus may include an impaction plate against which the conveyed material is directed to improve mixing and/or treatment. The improved apparatus are characterized by means of controlling the operation of the pneumatic or hydraulic transfer to enhance the mixing and/or reacting by controlling the flow of fluids, for example, air, into and out of the apparatus. The disclosed apparatus may be used to mix particulate material, for example, mortar; react fluids with particulate material; coat particulate material, or simply convey particulate material.

  9. Monitoring apparatus

    International Nuclear Information System (INIS)

    Keats, A.B.

    1981-01-01

    An improved monitoring apparatus for use with process plants, such as nuclear reactors, is described. System failure in the acquisition of data from the plant, owing to stuck signals, is avoided by arranging input signals from transducers in the plant in a test pattern. (U.K.)

  10. Prehensile apparatus

    Science.gov (United States)

    Smith, C.M.

    1993-10-12

    The present invention relates to an apparatus for handling a workpiece comprising a vessel that is longitudinally extensible and pressurizable, and a nonextensible and laterally flexible member on the vessel. The member constrains one side of the vessel to be nonextensible, causing the vessel to bend in the direction of the nonextensible member when pressurized. 8 figures.

  11. Closed-Loop Doluisio (Colon, Small Intestine) and Single-Pass Intestinal Perfusion (Colon, Jejunum) in Rat-Biophysical Model and Predictions Based on Caco-2.

    Science.gov (United States)

    Lozoya-Agullo, Isabel; Gonzalez-Alvarez, Isabel; Zur, Moran; Fine-Shamir, Noa; Cohen, Yael; Markovic, Milica; Garrigues, Teresa M; Dahan, Arik; Gonzalez-Alvarez, Marta; Merino-Sanjuán, Matilde; Bermejo, Marival; Avdeef, Alex

    2017-12-29

    The effective rat intestinal permeability (P eff ) was deconvolved using a biophysical model based on parameterized paracellular, aqueous boundary layer, transcellular permeabilities, and the villus-fold surface area expansion factor. Four types of rat intestinal perfusion data were considered: single-pass intestinal perfusion (SPIP) in the jejunum (n = 40), and colon (n = 15), closed-loop (Doluisio type) in the small intestine (n = 78), and colon (n = 74). Moreover, in vitro Caco-2 permeability values were used to predict rat in vivo values in the rat data studied. Comparable number of molecules permeate via paracellular water channels as by the lipoidal transcellular route in the SPIP method, although in the closed-loop method, the paracellular route appears dominant in the colon. The aqueous boundary layer thickness in the small intestine is comparable to that found in unstirred in vitro monolayer assays; it is thinner in the colon. The mucosal surface area in anaesthetized rats is 0.96-1.4 times the smooth cylinder calculated value in the colon, and it is 3.1-3.6 times in the small intestine. The paracellular permeability of the intestine appeared to be greater in rat than human, with the colon showing more leakiness (higher P para ) than the small intestine. Based on log intrinsic permeability values, the correlations between the in vitro and in vivo models ranged from r 2 0.82 to 0.92. The SPIP-Doluisio method comparison indicated identical log permeability selectivity trend with negligible bias.

  12. Radiography apparatus

    International Nuclear Information System (INIS)

    Redmayne, I.G.B.

    1985-01-01

    Apparatus for the inspection of pipe welds comprises a radiation source for transmitting radiation, say as X-rays, through a pipe weld and a detector in a box arranged diametrically opposite the source, with respect to the pipe, for detecting the transmitted radiation and providing electrical signals which are processed to produce an image of the weld. The source and detector are mounted on a frame which is rotatable about an inner frame clamped to the pipe. (author)

  13. Vortex Apparatus and Demonstrations

    Science.gov (United States)

    Shakerin, Said

    2010-05-01

    Vortex flow, from millimeter to kilometer in scale, is important in many scientific and technological areas. Examples are seen in water strider locomotion, from industrial pipe flow (wastewater treatment) to air traffic control (safe distance between aircrafts on a runway ready for takeoff) to atmospheric studies.2-5 In this paper, we focus on a particular vortex known as bathtub vortex (BTV). It occurs when water is drained from a hole at the bottom of a container such as a bathtub or a sink under the action of gravity. The vortex has a funnel shape with a central air core, resembling a tornado. We have designed a portable apparatus to demonstrate bathtub vortex on a continual basis. The apparatus consists of a clear cylinder supported by a frame over a water reservoir and a submersible pump. Young and old have been equally amazed by watching the demonstrations at various public presentations held at the University of the Pacific recently. With material cost of less than 100, the apparatus can be easily fabricated and used at other universities. With a short set-up time, it is an ideal device for promoting science to the general public, and it can be used to enhance lectures in physics courses as well.

  14. Preliminary Study on Mass Flow Rate in Passive Cooling Experimental Simulation During Transient Using NC-Queen Apparatus

    Directory of Open Access Journals (Sweden)

    M. Juarsa

    2014-12-01

    Full Text Available The research related to thermal management has been significantly inreased, especially for NPP safety. The use of passive cooling systems both during the accident and operation become reliable in the advanced reactor safety systems. Therefore it should be enhanced through experimental studies to investigate heat transfer phenomenon of the heat decay in transient cooling condition.An investigation has been performed through experiment using an NC-Queen apparatusconstructed with rectangular loop. Piping were consisting of tubes of SS316L with diameter, length, and width of 3/4 inch, 2.7 m, and 0.5 m respectively. The height between heater and cooler was 1.4 m. The experiment used initial water temperature at 70oC, 80oC, and 90oC in heater area. Transient temperature was used as experimental data to calculate water mass flow rate. The results showed that the temperature in heater area and cooler area were decreasing of about 90.6% and 95.7% at initial temperatur of 80oC, and of about 71.1% and 59.4% at initial temperature of 70oC. Those results were at higher initial temperature of 90oC compared with the initial temperature of 90oC. The average of water mass flow rate increased 81.03% from initial temperatur of 70oC. It was shown that the averages of removed heat in every second from water due to heat loss and cooler,were 3.51 watts, 5.06 watts and 6.85 watts respectively. The initial condition of heat stored in the water was quite different, but to the cooler heat removal capacity and heat loss was almost the same.

  15. Positioning apparatus

    Science.gov (United States)

    Vogel, Max A.; Alter, Paul

    1986-01-01

    An apparatus for precisely positioning materials test specimens within the optimum neutron flux path emerging from a neutron source located in a housing. The test specimens are retained in a holder mounted on the free end of a support pivotably mounted and suspended from a movable base plate. The support is gravity biased to urge the holder in a direction longitudinally of the flux path against the housing. Means are provided for moving the base plate in two directions to effect movement of the holder in two mutually perpendicular directions normal to the axis of the flux path.

  16. Apparatus for processing fibrous pulp material

    NARCIS (Netherlands)

    Dekker, J.C.; Bouma, H.; Mulder, F.B.M.

    2008-01-01

    The invention relates to an apparatus (1) for processing a flow of pulp comprising fibrous material, in particular pulp comprising cellulose fibres for making paper, said apparatus comprising a drum (2) having a rotational axis (R), an inlet end (3), an outlet end (4) and an inner surface, a

  17. Air-cleaning apparatus

    International Nuclear Information System (INIS)

    Howard, A.G.

    1981-01-01

    An air-cleaning, heat-exchange apparatus includes a main housing portion connected by means of an air inlet fan to the kitchen exhaust stack of a restaurant. The apparatus includes a plurality of heat exchangers through which a heat-absorptive fluid is circulated, simultaneously, by means of a suitable fluid pump. These heat exchangers absorb heat from the hot exhaust gas, out of the exhaust stack of the restaurant, which flows over and through these heat exchangers and transfers this heat to the circulating fluid which communicates with remote heat exchangers. These remote heat exchangers further transfer this heat to a stream of air, such as that from a cold-air return duct for supplementing the conventional heating system of the restaurant. Due to the fact that such hot exhaust gas is heavily grease laden , grease will be deposited on virtually all internal surfaces of the apparatus which this exhaust gas contacts. Consequently, means are provided for spraying these contacted internal surfaces , as well as the hot exhaust gas itself, with a detergent solution in which the grease is soluble, thereby removing grease buildup from these internal surfaces

  18. Isotope diagnostics apparatus

    International Nuclear Information System (INIS)

    Herrschaft, H.

    1976-01-01

    The invention relates to a measuring probe for an isotope diagnostics apparatus to determine the distribution of radioactive substances in a body by measuring the radiation emanating from this body by means of a multiplicity of measuring probes directed simultaneously towards areas of measuring surfae and carried in guidances of a holding block. The measuring results of the individual probes are recorded separately, thus allowing the possibility of being evaluated separately, too. Measuring probes of this kind are used in multi-channel measuring objects and are useful particularly for determining the regional cerebral blood flow. (orig./ORU) [de

  19. MEASURING APPARATUS

    Science.gov (United States)

    Kohman, T.P.; Weissbourd, B.W.

    1959-02-17

    An ion chamber assembly is presented for measuring neutron emission of a relatively slow rate from a radioactive sample. The detecting apparatus comprises a container filled with neutron slowing material and having a cavity where a neutron source may be located centrally in the container. A plurality of ion chamber units are disposed equidistantly from the source and from each other for detecting the neutron radiation. Each of the ion chamber units has an ion chamber and a second chamber of substantially the same diameter as the ion chamber and in end-to-end relationship therewith. The second chamber contains paraffin and an axially disposed lead-in conductor for the ion chamber central electrode. The preamplifier circuit whose input is connected to the lead-in conductor is housed in a third container arranged in end-to-end relationship with the second chamber.

  20. Hydrogenation apparatus

    Science.gov (United States)

    Friedman, Joseph [Encino, CA; Oberg, Carl L [Canoga Park, CA; Russell, Larry H [Agoura, CA

    1981-01-01

    Hydrogenation reaction apparatus comprising a housing having walls which define a reaction zone and conduits for introducing streams of hydrogen and oxygen into the reaction zone, the oxygen being introduced into a central portion of the hydrogen stream to maintain a boundary layer of hydrogen along the walls of the reaction zone. A portion of the hydrogen and all of the oxygen react to produce a heated gas stream having a temperature within the range of from 1100.degree. to 1900.degree. C., while the boundary layer of hydrogen maintains the wall temperature at a substantially lower temperature. The heated gas stream is introduced into a hydrogenation reaction zone and provides the source of heat and hydrogen for a hydrogenation reaction. There also is provided means for quenching the products of the hydrogenation reaction. The present invention is particularly suitable for the hydrogenation of low-value solid carbonaceous materials to provide high yields of more valuable liquid and gaseous products.

  1. Apparatus for entrained coal pyrolysis

    Science.gov (United States)

    Durai-Swamy, Kandaswamy

    1982-11-16

    This invention discloses a process and apparatus for pyrolyzing particulate coal by heating with a particulate solid heating media in a transport reactor. The invention tends to dampen fluctuations in the flow of heating media upstream of the pyrolysis zone, and by so doing forms a substantially continuous and substantially uniform annular column of heating media flowing downwardly along the inside diameter of the reactor. The invention is particularly useful for bituminous or agglomerative type coals.

  2. A novel high performance stopped-flow apparatus equipped with a special constructed mixing chamber containing a plunger under inert condition with a very short dead-time to investigate very rapid reactions

    Directory of Open Access Journals (Sweden)

    Sayyed Mostafa Habibi Khorassani

    2015-11-01

    Full Text Available The present work set out to establish a novel stopped-flow instrument equipped with a special constructed mixing chamber containing a plunger to enable a kinetic study of the very rapid reactions under a dry inert atmosphere glove bag, in particular, for the reactions are sensitive to moisture or air. A stopped-flow spectrophotometer is essentially a conventional spectrophotometer with the addition of a system for rapid mixing of solutions. The purpose of this work is to describe the fabrication and evaluation of specially constructed and in-expensive stopped-flow system. The evaluation includes determination of the dead-time, relative mixing efficiency, and the measurement of known rate constants. Herein, a dead-time of about 3.4 ms was determined in the final modified construction of the stopped-flow apparatus in order to investigate the rapid initial during which some form of reaction intermediate is presented to be formed.

  3. Apparatus, System, And Method For Roadway Monitoring

    KAUST Repository

    Claudel, Christian G.

    2015-06-02

    An apparatus, system, and method for monitoring traffic and roadway water conditions. Traffic flow and roadway flooding is monitored concurrently through a wireless sensor network. The apparatus and system comprises ultrasound rangefinders monitoring traffic flow, flood water conditions, or both. Routing information may be calculated from the traffic conditions, such that routes are calculated to avoid roadways that are impassable or are slow due to traffic conditions.

  4. Purification apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Mortenson, C.W.

    1982-04-27

    An apparatus is provided for converting sea or other undrinkable waters to drinkable water without the use of driven or moving parts. Reliance upon gradient effects is made to effect the vaporization of, for example, sea water, followed by the condensation of the vapor to form distilled water. Gradient effects are achieved through the provision of differentials in the thermal conductivity, capillary activity, adsorptive, absorptive and/or pressure characteristics of particulate materials, or combinations of such physicals. For example, a column is packed with material graded as to its conductivity, the least thermally conductive material being nearest the cold or ambient water that is to be purified. In packing the column each successive layer of material has a greater thermal conductivity than the layer beneath it with the most conductive being at the top near the outlet arm of the column. The final outlet arm or tube is unheated or is at a temperature lower than that of the topmost conductive material so that vapor reaching the outlet tube gets condensed. This tube leads to a container kept in a cool place as, for example, buried in the ground, as, for instance, at the seashore deep enough to be cooled or to be surrounded by water, thus keeping the condensate cold. Pure water so collected is removed by such means as is desired. Other impure, volatile liquids may be similarly purified.

  5. Apparatus for diffusion separation

    International Nuclear Information System (INIS)

    Nierenberg, W.A.

    1976-01-01

    A diffuser separator apparatus is described which comprises a plurality of flow channels in a single stage. Each of said channels has an inlet port and an outlet port and a constant cross sectional area between said ports. At least a portion of the defining surface of each of said channels is a diffusion separation membrane, and each of said channels is a different cross sectional area. Means are provided for connecting said channels in series so that each successive channel of said series has a smaller cross sectional area than the previous channel of said series. Also provided are a source of gaseous mixture, individual means for flowing said gaseous mixture to the inlet port of each of said channels, gas receiving and analyzing means, individual means for flowing gas passing from each of said outlet ports and means for flowing gas passing through said membranes to said receiving and analyzing means, and individual means for connecting the outlet port of each channel with the inlet port of the channel having the next smaller cross sectional area

  6. Methods and apparatus for handling or treating particulate material

    Science.gov (United States)

    Littman, Howard (Inventor); Plawsky, Joel L. (Inventor); Paccione, John D. (Inventor)

    2009-01-01

    An improved draft tube spout fluid bed (DTSFB) mixing, handling, conveying, and treating apparatus and systems, and methods for operating are provided. The apparatus and systems can accept particulate material and pneumatically or hydraulically conveying the material to mix and/or treat the material. In addition to conveying apparatus, a collection and separation apparatus adapted to receive the conveyed particulate material is also provided. The collection apparatus may include an impaction plate against which the conveyed material is directed to improve mixing and/or treatment. The improved apparatus are characterized by means of controlling the operation of the pneumatic or hydraulic transfer to enhance the mixing and/or reacting by controlling the flow of fluids, for example, air, into and out of the apparatus. The disclosed apparatus may be used to mix particulate material, for example, mortar; react fluids with particulate material; coat particulate material, or simply convey particulate material.

  7. Gamma apparatuses for radiotherapy

    International Nuclear Information System (INIS)

    Sul'kin, A.G.

    1986-01-01

    Scientific and technical achievements in development and application of gamma therapeutic apparatuses for external and intracavity irradiations are generalized. Radiation-physical parameters of apparatuses providing usability of progressive methods in radiotherapy of onclogical patients are given. Optimization of main apparatus elements, ensurance of its operation reliability, reduction of errors of irradiation plan reproduction are considered. Attention is paid to radiation safety

  8. Apparatus for controlling nuclear core debris

    International Nuclear Information System (INIS)

    Jones, R.D.

    1978-01-01

    Disclosed is an apparatus for containing, cooling, and dispersing reactor debris assumed to flow from the core area in the unlikely event of an accident causing core meltdown. The apparatus includes a plurality of horizontally disposed vertically spaced plates, having depressions to contain debris in controlled amounts, and a plurality of holes therein which provide natural circulation cooling and a path for debris to continue flowing downward to the plate beneath. The uppermost plates may also include generally vertical sections which form annular-like flow areas which assist the natural circulation cooling

  9. Radiative Gasification Apparatus

    Data.gov (United States)

    Federal Laboratory Consortium — This apparatus, developed at EL, determines gasification rate (mass loss rate) of a horizontally oriented specimen exposed in a nitrogen environment to a controlled...

  10. ROLLER FILTRATION APPARATUS

    DEFF Research Database (Denmark)

    2017-01-01

    a medium, comprising a plurality of press rollers, a separation chamber for receiving the medium and defined, in cross section, by the press rollers, and at least one chamber filter located inside and enclosed by the separation chamber. The apparatus is preferably configured such that a negative pressure......The present invention relates to the field of filtering, more precisely the present invention concerns an apparatus and a method for the separation of dry matter from a medium and the use of said apparatus. One embodiment discloses an apparatus for the separation of dry matter and liquid from...

  11. Apparatus for Teaching Physics.

    Science.gov (United States)

    Gottlieb, Herbert H., Ed.

    1981-01-01

    Describes: (1) a variable inductor suitable for an inductance-capacitance bridge consisting of a fixed cylindrical solenoid and a moveable solenoid; (2) long-range apparatus for demonstrating falling bodies; and (3) an apparatus using two lasers to demonstrate ray optics. (SK)

  12. Multipurpose Thermal Insulation Test Apparatus

    Science.gov (United States)

    Fesmire, James E. (Inventor); Augustynowicz, Stanislaw D. (Inventor)

    2002-01-01

    A multi-purpose thermal insulation test apparatus is used for testing insulation materials, or other components. The test apparatus is a fluid boil-off calorimeter system for calibrated measurement of the apparent thermal conductivity (k-value) of a specimen material at a fixed vacuum level. The apparatus includes an inner vessel for receiving a fluid with a normal boiling point below ambient temperature, such as liquid nitrogen, enclosed within a vacuum chamber. A cold mass assembly, including the inner vessel and thermal guards, is suspended from the top of the vacuum chamber. Handling tools attach to the cold mass assembly for convenient manipulation of the assembly and for the installation or wrapping of insulation test materials. Liquid nitrogen is typically supplied to the inner vessel using a fill tube with funnel. A single port through the top of the vacuum chamber facilitates both filling and venting. Aerogel composite stacks with reflective films are fastened to the top and the bottom of the inner vessel as thermal guards. The comparative k-value of the insulation material is determined by measuring the boil-off flow rate of gas, the temperature differential across the insulation thickness, and the dimensions (length and diameters) of the test specimen.

  13. Apparatus for making molten silicon

    Science.gov (United States)

    Levin, Harry (Inventor)

    1988-01-01

    A reactor apparatus (10) adapted for continuously producing molten, solar grade purity elemental silicon by thermal reaction of a suitable precursor gas, such as silane (SiH.sub.4), is disclosed. The reactor apparatus (10) includes an elongated reactor body (32) having graphite or carbon walls which are heated to a temperature exceeding the melting temperature of silicon. The precursor gas enters the reactor body (32) through an efficiently cooled inlet tube assembly (22) and a relatively thin carbon or graphite septum (44). The septum (44), being in contact on one side with the cooled inlet (22) and the heated interior of the reactor (32) on the other side, provides a sharp temperature gradient for the precursor gas entering the reactor (32) and renders the operation of the inlet tube assembly (22) substantially free of clogging. The precursor gas flows in the reactor (32) in a substantially smooth, substantially axial manner. Liquid silicon formed in the initial stages of the thermal reaction reacts with the graphite or carbon walls to provide a silicon carbide coating on the walls. The silicon carbide coated reactor is highly adapted for prolonged use for production of highly pure solar grade silicon. Liquid silicon (20) produced in the reactor apparatus (10) may be used directly in a Czochralski or other crystal shaping equipment.

  14. Wear resistance studies of an austempered ductile iron with the aid of a single pass grooving pendulum; Estudo do comportamento em desgate de um ferro fundido nodular austemperado atraves da tecnica da tecnica de esclerometria pendular

    Energy Technology Data Exchange (ETDEWEB)

    Velez, J.M.; Tschiptschin, A.P. [Sao Paulo Univ., SP (Brazil). Escola Politecnica

    1995-12-31

    The abrasive wear resistance of an austempered ductile iron was studied with the aid of a single pass grooving pendulum. Specimens were austenitized at 860 deg C and austempered at 370 deg C for 30, 60, 90, 180 and 240 min. Austenite transformation kinetics was measured by quantitative metallography. Specimens for pendulum tests were gridded as squared based prisms (50 mm x 10 mm x 10 mm) and one of the faces submitted to metallographic polishing before the test. A hard metal cutting tool was used as abrasive. The absorbed energy as well as the loss of matter were measured. Scanning Electron Microscopy was used to analyze the surface topography of the scratched specimen. It was observed a maximum in the absorbed specific energy for the specimen treated for 60 min. with a microstructure of bainite ferrite plus plus 42% volume fraction of retained austenite. All other structures (ferrite plus carbides, ferrite plus lower contents of austenite and martensite plus austenite) gave lower values of absorbed specific energy. Observation of scratches and chips formed on the surface of the specimen can explain the above mentioned behaviour 12 refs., 11 figs., 2 tabs.

  15. A new anaesthetic breathing system combining Mapleson A, D and E principles. A simple apparatus for low flow universal use without carbon dioxide absorption.

    Science.gov (United States)

    Humphrey, D

    1983-04-01

    A new simple anaesthetic breathing system is described which has been designed to incorporate into a single system advantages of Mapleson A, D and E type systems. Coaxial and non-coaxial versions are available. The system can be used for adults, children or neonates and allows both spontaneous or controlled ventilation with low fresh gas flows at all times. As a Mapleson A system for spontaneous respiration a considerable saving of anaesthetic gases and vapours is achieved since, for adults, the new system requires a lower fresh gas flow even than that for the Magill. For children breathing spontaneously the system requires only one third of the fresh gas flow necessary for the Jackson Rees modification of Ayre's T-piece. For controlled ventilation the system behaves as a modified Mapleson D/E (Bain type) system with the advantage of predictable CO2 tensions and good humidification. The system is safe, simple in design and operation, and is easily sterilized. Further it offers low resistance to expiration and facilitates scavenging at all times which, with low anaesthetic gas flows, permits complete theatre pollution control. Its potential application in academic and rural environments and major advantages over the circle absorber system are discussed.

  16. Coating and curing apparatus and methods

    Science.gov (United States)

    Brophy, Brenor L; Maghsoodi, Sina; Neyman, Patrick J; Gonsalves, Peter R; Hirsch, Jeffrey G; Yang, Yu S

    2015-02-24

    Disclosed are coating apparatus including flow coating and roll-coating that may be used for uniform sol-gel coating of substrates such as glass, solar panels, windows or part of an electronic display. Also disclosed are methods for substrate preparation, flow coating and roll coating. Lastly systems and methods for skin curing sol-gel coatings deposited onto the surface of glass substrates using a high temperature air-knife are disclosed.

  17. Mirror plasma apparatus

    International Nuclear Information System (INIS)

    Moir, R.W.

    1981-01-01

    A mirror plasma apparatus which utilizes shielding by arc discharge to form a blanket plasma and lithium walls to reduce neutron damage to the wall of the apparatus. An embodiment involves a rotating liquid lithium blanket for a tandem mirror plasma apparatus wherein the first wall of the central mirror cell is made of liquid lithium which is spun with angular velocity great enough to keep the liquid lithium against the first material wall, a blanket plasma preventing the lithium vapor from contaminating the plasma

  18. Method and apparatus to produce and maintain a thick, flowing, liquid lithium first wall for toroidal magnetic confinement DT fusion reactors

    Science.gov (United States)

    Woolley, Robert D.

    2002-01-01

    A system for forming a thick flowing liquid metal, in this case lithium, layer on the inside wall of a toroid containing the plasma of a deuterium-tritium fusion reactor. The presence of the liquid metal layer or first wall serves to prevent neutron damage to the walls of the toroid. A poloidal current in the liquid metal layer is oriented so that it flows in the same direction as the current in a series of external magnets used to confine the plasma. This current alignment results in the liquid metal being forced against the wall of the toroid. After the liquid metal exits the toroid it is pumped to a heat extraction and power conversion device prior to being reentering the toroid.

  19. Realtime radiation exposure monitor and control apparatus

    International Nuclear Information System (INIS)

    Cowart, R.W.

    1981-01-01

    This patent application relates to an apparatus and methods used to obtain image information from modulation of a uniform flux. An exposure measuring apparatus is disclosed which comprises a multilayered detector structure having an external circuit connected to a transparent insulating layer and to a conductive plate a radiation source adapted to irradiate the detector structure with radiation capable of producing electron-hole pairs in a photoconductive layer of the detector wherein the flow of current within the external circuit is measured when the detector is irradiated by the radiation source. (author)

  20. Method and apparatus for combinatorial chemistry

    Science.gov (United States)

    Foote, Robert S [Oak Ridge, TN

    2012-06-05

    A method and apparatus are provided for performing light-directed reactions in spatially addressable channels within a plurality of channels. One aspect of the invention employs photoactivatable reagents in solutions disposed into spatially addressable flow streams to control the parallel synthesis of molecules immobilized within the channels. The reagents may be photoactivated within a subset of channels at the site of immobilized substrate molecules or at a light-addressable site upstream from the substrate molecules. The method and apparatus of the invention find particularly utility in the synthesis of biopolymer arrays, e.g., oligonucleotides, peptides and carbohydrates, and in the combinatorial synthesis of small molecule arrays for drug discovery.

  1. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are presented of a tomographic scanning apparatus, its rotational assembly, and the control and circuit elements, with particular reference to the amplifier and multiplexing circuits enabling detector signal calibration. (U.K.)

  2. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are given of a tomographic scanning apparatus, with particular reference to a multiplexer slip ring means for receiving output from the detectors and enabling interfeed to the image reconstruction station. (U.K.)

  3. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification relates to a tomographic scanning apparatus using a fan beam and digital output signal, and particularly to the design of the gas-pressurized ionization detection system. (U.K.)

  4. Thermal Acoustic Fatigue Apparatus

    Data.gov (United States)

    Federal Laboratory Consortium — The Thermal Acoustic Fatigue Apparatus (TAFA) is a progressive wave tube test facility that is used to test structures for dynamic response and sonic fatigue due to...

  5. Light shielding apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Richard Dean; Thom, Robert Anthony

    2017-10-10

    A light shielding apparatus for blocking light from reaching an electronic device, the light shielding apparatus including left and right support assemblies, a cross member, and an opaque shroud. The support assemblies each include primary support structure, a mounting element for removably connecting the apparatus to the electronic device, and a support member depending from the primary support structure for retaining the apparatus in an upright orientation. The cross member couples the left and right support assemblies together and spaces them apart according to the size and shape of the electronic device. The shroud may be removably and adjustably connectable to the left and right support assemblies and configured to take a cylindrical dome shape so as to form a central space covered from above. The opaque shroud prevents light from entering the central space and contacting sensitive elements of the electronic device.

  6. Fuel pellet loading apparatus

    International Nuclear Information System (INIS)

    1980-01-01

    Apparatus is described for loading a predetermined amount of nuclear fuel pellets into nuclear fuel elements and particularly for the automatic loading of fuel pellets from within a sealed compartment. (author)

  7. Apparatus for drying sugar cubes

    NARCIS (Netherlands)

    Derckx, H.A.J.; Torringa, H.M.

    1999-01-01

    Device for drying sugar cubes containing a heating apparatus for heating and dehumidifying the sugar cubes, a conditioning apparatus for cooling off and possibly further dehumidifying the sugar cubes and a conveying apparatus for conveying the sugar cubes through the heating apparatus and the

  8. Test sample handling apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    A test sample handling apparatus using automatic scintillation counting for gamma detection, for use in such fields as radioimmunoassay, is described. The apparatus automatically and continuously counts large numbers of samples rapidly and efficiently by the simultaneous counting of two samples. By means of sequential ordering of non-sequential counting data, it is possible to obtain precisely ordered data while utilizing sample carrier holders having a minimum length. (U.K.)

  9. Sludge recovery apparatus

    International Nuclear Information System (INIS)

    Marmo, A.R.

    1979-01-01

    An improved design of a sludge recovery apparatus used in the fabrication of nuclear fuel is described. This apparatus provides for automatic separation of sludge from the grinder coolant, drying of the sludge into a flowable powder and transfer of the dry powder to a salvage container. It can be constructed to comply with criticality-safe-geometry requirements and to obviate need for operating personnel in its immediate vicinity. (UK)

  10. X-ray apparatus

    International Nuclear Information System (INIS)

    Tomita, Chuji.

    1980-01-01

    A principal object of the present invention is to provide an X-ray apparatus which is such that the distance between the surface of the patient's table and the floor on which the apparatus is installed is sufficiently small in the horizontal position of the patient's table of the roentgenographical pedestal and that the rotation of the pedestal from the horizontal position to a tilted position and further to the vertical position of the table can be carried out smoothly. (auth)

  11. Thermal energy test apparatus

    Science.gov (United States)

    Audet, N. F.

    1991-10-01

    The Navy Clothing and Textile Research Facility (NCTRF) designed and fabricated a thermal energy test apparatus to permit evaluation of the heat protection provided by crash crew firefighter's proximity clothing materials against radiant and convective heat loads, similar to those found outside the flame zone of aircraft fuel fires. The apparatus employs electrically operated quartz lamp radiant heaters and a hot air convective heater assembly to produce the heat load conditions the materials to be subjected to, and is equipped with heat flux sensors of different sensitivities to measure the incident heat flux on the sample material as well as the heat flux transmitted by the sample. Tests of the apparatus have shown that it can produce radiant heat flux levels equivalent to those estimated to be possible in close proximity to large aircraft fuel fires, and can produce convective heat fluxes equivalent to those measured in close proximity to aircraft fuel fires at upwind and sidewind locations. Work was performed in 1974.

  12. Computed tomography apparatus

    International Nuclear Information System (INIS)

    Palermo, A.; Zupancic, A.

    1981-01-01

    A computed tomography (CT) scanner apparatus including improved arrangement for transferring high voltage electrical energy between a stationary gantry and a rotating assembly is described. The assembly carries the X-ray source and has an opening defining an aperture to receive a part of a patient. A first axis about which the assembly rotates, passes through the aperture. The apparatus includes a number of slip rings which are used for effecting the transfer of the electrical energy. Respective portions of the gantry and rotating assembly define a cavity which contains an insulating di-electric fluid in which the slip rings are immersed. The apparatus is of compact design and, further, the rotating assembly and the slip rings can be tilted about a second axis which intersects the first axis. (author)

  13. Pore roller filtration apparatus

    DEFF Research Database (Denmark)

    2014-01-01

    The present invention relates to the field of filtering, more precisely the present invention concerns an apparatus and a method for the separation of dry matter from a medium and the use of said apparatus. One embodiment discloses an apparatus for the separation of dry matter from a medium, comp...... of a pore roller and one other roller, means for establishing a pressure difference across the filter, means for passing filter and filter cake through the set of rollers, and a closure mechanism configured to control the transverse tension between the rollers......., comprising a pressure regulated separation chamber defined, in cross section, by a plurality of rollers mounted between opposing sidewalls, each of said rollers having a shaft adapted to be engaged with the sidewalls, a filter arranged so that it passes between at least one set of said rollers consisting...

  14. Experimental determination of critical data of multi-component mixtures containing potential gasoline additives 2-butanol by a flow-type apparatus

    International Nuclear Information System (INIS)

    He, Maogang; Xin, Nan; Wang, Chengjie; Liu, Yang; Zhang, Ying; Liu, Xiangyang

    2016-01-01

    Graphical abstract: Experimental critical pressures of 2-butanol + hexane + heptane system. - Highlights: • Critical properties of six binary systems and two ternary systems were measured. • Six binary systems containing 2-butanol show non-ideal behavior in their T c –x 1 curves. • Non-ideal behavior of mixtures with 2-butanol relies on azeotropy. • Experimental data for binary systems were fitted well with Redlich–Kister equation. • Critical surfaces of ternary systems were plotted using the Cibulka’s expressions. - Abstract: In this work, we used a flow method for measurement of critical properties of six binary mixtures (2-butanol + cyclohexane, 2-butanol + hexane, 2-butanol + heptane, 2-butanol + octane, 2-butanol + nonane and 2-butanol + decane) and two ternary mixtures (2-butanol + hexane + heptane and 2-butanol + octane + decane). The critical properties were determined by observing the disappearance and reappearance of the gas–liquid phase meniscus in a quartz glass tube. The standard uncertainties of temperatures and pressures for both binary and ternary mixtures were estimated to be less than 0.2 K and 5.2 kPa, respectively. These critical data provide the boundaries of the two-phase regions of the related mixture systems. Six binary systems show non-ideal behaviors in the loci of critical temperatures. We used the Redlich–Kister equations to correlate the critical temperatures and pressures of these systems and listed the binary interaction parameters. The maximum average absolute deviation (AAD) of each binary system between experimental data and calculated results from Redlich–Kister equations is 0.038% for critical temperatures, and 0.244% for critical pressures. Moreover, the two ternary systems were newly reported and correlated by Cibulka’s and Singh’s expressions. The maximum AAD of critical temperatures and critical pressures are 0.103% and 0.433%, respectively.

  15. Electroplating method and apparatus

    International Nuclear Information System (INIS)

    Looney, R.B.; Smith, W.E.L.

    1978-01-01

    Disclosed is an apparatus for high speed electroplating or anodizing tubular members such as nuclear reactor fuel elements. A loading arm positions the member on a base for subsequent support by one of two sets of electrical contacts. A carriage assembly positions electrodes into and around the member. Electrolyte is pumped between the electrodes and the member while electric current is applied. Programmed controls sequentially employ each of the two sets of contacts to expose all surfaces of the member to the electrolyte. The member is removed from the apparatus by an unloading arm

  16. APPARATUS FOR LIQUID PHASE EXTRACTION

    Science.gov (United States)

    Hicks, T.R.; Lehman, H.R.; Rubin, B.

    1958-09-16

    operation is described. It comprises a tubular colunm having upper and lower enlarged terminal portions, and a constricted central section containing fluid dispersal packing. Pulsing means are coupled to the upper portion of the column. The inlet for the less dense phase is located above the inlet for the denser phase and both are positioned so that liquids enter the constricted packingfilled central section. The apparatos also includes an interfacing level control, and means fer sensing the level of the interface actuate apparatus for controlling the rate of flow of input or discharge. The outlet for the less dense phase is located in the upper packing free portion of the colunm and that of the denser phase in the lower portion.

  17. Positioning and locking apparatus

    Science.gov (United States)

    Hayward, M.L.; Harper, W.H.

    1985-06-19

    A positioning and locking apparatus including a fixture having a rotatable torque ring provided with a plurality of cam segments for automatically guiding a container into a desired location within the fixture. Rotation of the ring turns the container into a final position in pressure sealing relation against a hatch member.

  18. Apparatus for Teaching Physics.

    Science.gov (United States)

    Gottlieb, Herbert H., Ed.

    1979-01-01

    Six different pieces of physics apparatus are described: Telsa Coil for instant ignition of sodium arc lamps, Timekube, Magnetic Maps of the United States, a slinky with vertical mounting, a wave generator power supply, and a long-period timer power switch. Price and supplier are included. (BT)

  19. communication method and apparatus

    DEFF Research Database (Denmark)

    2005-01-01

    The present invention relates to a non-lingual communication method and apparatus, wherein a physical or physiological signal consciously created by a first subject (1) is detected and converted into a transmitted output signal presented to a second subject (7) in order to communicate information...

  20. Electrolysis apparatus and method

    International Nuclear Information System (INIS)

    1975-01-01

    A procedure in which electrolysis is combined with radiolysis to improve the reaction yield is proposed for the production of hydrogen and oxygen from water. An apparatus for this procedure is disclosed. High-energy electric pulses are applied between the anode and kathode of an electrolytical cell in such a way that short-wave electromagnetic radiation is generated at the same time

  1. Mobile lighting apparatus

    Science.gov (United States)

    Roe, George Michael; Klebanoff, Leonard Elliott; Rea, Gerald W; Drake, Robert A; Johnson, Terry A; Wingert, Steven John; Damberger, Thomas A; Skradski, Thomas J; Radley, Christopher James; Oros, James M; Schuttinger, Paul G; Grupp, David J; Prey, Stephen Carl

    2013-05-14

    A mobile lighting apparatus includes a portable frame such as a moveable trailer or skid having a light tower thereon. The light tower is moveable from a stowed position to a deployed position. A hydrogen-powered fuel cell is located on the portable frame to provide electrical power to an array of the energy efficient lights located on the light tower.

  2. Building scientific apparatus

    National Research Council Canada - National Science Library

    Moore, John H; Davis, Christopher C; Coplan, Michael A; Greer, Sandra C

    2009-01-01

    ... specification of the components of apparatus, many new to this edition. Data on the properties of materials and components used by manufacturers are included. Mechanical, optical, and electronic construction techniques carried out in the laboratory, as well as those let out to specialized shops, are also described. Step-by-step instruc...

  3. Continuous microwave regeneration apparatus for absorption media

    Science.gov (United States)

    Smith, Douglas D.

    1999-01-01

    A method and apparatus for continuously drying and regenerating ceramic beads for use in process gas moisture drying operations such as glove boxes. A microwave energy source is coupled to a process chamber to internally heat the ceramic beads and vaporize moisture contained therein. In a preferred embodiment, the moisture laden ceramic beads are conveyed toward the microwave source by a screw mechanism. The regenerated beads flow down outside of the screw mechanism and are available to absorb additional moisture.

  4. Filter material charging apparatus for filter assembly for radioactive contaminants

    International Nuclear Information System (INIS)

    Goldsmith, J.M.; O'Nan, A. Jr.

    1977-01-01

    A filter charging apparatus for a filter assembly is described. The filter assembly includes a housing with at least one filter bed therein and the filter charging apparatus for adding filter material to the filter assembly includes a tank with an opening therein, the tank opening being disposed in flow communication with opposed first and second conduit means, the first conduit means being in flow communication with the filter assembly housing and the second conduit means being in flow communication with a blower means. Upon activation of the blower means, the blower means pneumatically conveys the filter material from the tank to the filter housing

  5. Development of an experimental apparatus for nucleate boiling analysis

    International Nuclear Information System (INIS)

    Castro, A.J.A. de.

    1984-01-01

    An experimental apparatus is developed for the study of the parameters that affect nucleate boiling. The experimental set up is tested for nucleate boiling in an annular test section with subcooled water flow. The following parameters are analysed: pressure, fluid velocity and the fluid temperature at the test section entrance. The performance of the experimental apparatus is analysed by the results and by the problems raised by the operation of the setup. (Author) [pt

  6. Study of Absorption Characteristics of the Total Saponins from Radix Ilicis Pubescentis in an In Situ Single-Pass Intestinal Perfusion (SPIP Rat Model by Using Ultra Performance Liquid Chromatography (UPLC

    Directory of Open Access Journals (Sweden)

    Guojun Kuang

    2017-11-01

    Full Text Available In contrast to the extensively reported therapeutic activities, far less attention has been paid to the intestinal absorption of the total saponins from Radix Ilicis Pubescentis (in Chinese Mao-Dong-Qing, MDQ. This study aimed to investigate the intestinal absorption characteristics of ilexgenin A (C1, ilexsaponin A1 (C2, ilexsaponin B1 (C3, ilexsaponin B2 (C4, ilexsaponin B3 (DC1, and ilexoside O (DC2 when administrated with the total saponins from MDQ (MDQ-TS. An UPLC method for simultaneous determination of C1, C2, C3, C4, DC1, and DC2 in intestinal outflow perfusate was developed and validated. The absorption characteristics of MDQ-TS were investigated by evaluating the effects of intestinal segments, drug concentration, P-glycoprotein (P-gp inhibitor (verapomil, endocytosis inhibitor (amantadine and ethylene diamine tetraacetic acid (EDTA, tight junction modulator on the intestinal transportation of MDQ-TS by using a single-pass intestinal perfusion (SPIP rat model, and the influence of co-existing components on the intestinal transport of the six saponins was discussed. The results showed that effective apparent permeability (Papp of C1, C2, C3, C4, and DC2 administrated in MDQ-TS form had no segment-dependent changes at low and middle dosage levels. C1, C2, C3, D4, DC1, and DC2 administrated in MDQ-TS form all exhibited excellent transmembrane permeability with Papp > 0.12 × 10−2 cm·min−1. Meanwhile, Papp and effective absorption rate constant (Ka values for the most saponins showed concentration dependence and saturation characteristics. After combining with P-gp inhibitor of verapamil, Papp of C2, C3, and DC1 in MDQ-TS group was significantly increased up to about 2.3-fold, 1.4-fold, and 3.4-fold, respectively in comparison to that of non-verapamil added group. Verapamil was found to improve the absorption of C2, C3, and DC1, indicating the involvement of an active transport mechanism in the absorption process. Compared with the

  7. Improvements in measuring apparatus

    International Nuclear Information System (INIS)

    Casey, W.

    1976-01-01

    Measuring apparatus is described that is suitable for gauging the wall profiles of downwardly extending channels in nuclear reactors, but which is equally applicable to channels such as pipe bores and conduits in other types of plant. The apparatus comprises a probe carrying a measuring transducer giving an electrical output. The probe support may be moved stepwise along the channel along a track between end members. An electrical conductor is provided for transmitting the electrical output of the transducer to an indicator located remote from the probe. The probe support may consist of a cable attached at one end to a winding drum, and incorporating an electrical conductor connected to the transducer. Channel engaging means are provided on the probe that permits free upward movement of the probe when the latter is suspended by the cable and moves into gripping engagement with the channel wall when the tension in the cable is relaxed. (U.K.)

  8. Portable shower apparatus

    Science.gov (United States)

    Grenier, Francis E. (Inventor)

    1993-01-01

    A multipurpose, collapsible, shower apparatus for use almost anywhere but especially adapted for use in places somewhat remote from civilization such as recreational vehicles, campers, the outdoors, space vehicles and the like where there may be a limited amount of water or other liquid. The collapsible shower apparatus includes a curtain assembly having an inner wall, an outer wall and a porous element for separating the inner and outer walls; a series of spaced hollow hoops connected by one or more sets of hollow tubes (manifolds); one or more nozzles connected to and in communication with at least one of the hollow hoops; a source of fluid under pressure in communication with at least one of the hollow hoops; and a suction pump for withdrawing fluid from the interior of the curtain assembly.

  9. Radiation guard apparatus

    International Nuclear Information System (INIS)

    Collica, C.; Epifano, L.; Farella, R.

    1976-01-01

    Radiation shielding apparatus for use in conjunction with a pad on a table. The apparatus comprises a set of units, each unit comprising a pair of joined substantially flat orthogonal flaps. The flaps are formed of a radiation shielding material and are adapted for removable placement under the pad whereby one flap contacts the table and the other flap extends vertically from an edge thereof. In a preferred embodiment of the invention the set consists of five units that provide protection around three sides of a rectangular table. In this embodiment, two of the units are identical and have asymmetrical trapezoidal flaps, and two others of the units are also identical, but have trapezoidal flaps which are of reversed orientation with respect to the first-mentioned two units. 6 claims, 4 drawing figures

  10. Flow

    DEFF Research Database (Denmark)

    Knoop, Hans Henrik

    2006-01-01

    FLOW. Orden i hovedet på den fede måde Oplevelsesmæssigt er flow-tilstanden kendetegnet ved at man er fuldstændig involveret, fokuseret og koncentreret; at man oplever stor indre klarhed ved at vide hvad der skal gøres, og i hvilket omfang det lykkes; at man ved at det er muligt at løse opgaven...

  11. Apparatus for obtaining radiographs

    International Nuclear Information System (INIS)

    Frank, L.F.

    1977-01-01

    An apparatus for making x-ray pictures by imagewise exposing a cloud chamber containing a high atomic number gas mixed with a condensate vapor is described. The gas is under sufficiently high pressure to assure substantially complete absorption of the incident x-rays. Optical means are provided so that visible x-ray tracks are viewed from a direction aligned with the tracks

  12. Automatic temperature adjustment apparatus

    Science.gov (United States)

    Chaplin, James E.

    1985-01-01

    An apparatus for increasing the efficiency of a conventional central space heating system is disclosed. The temperature of a fluid heating medium is adjusted based on a measurement of the external temperature, and a system parameter. The system parameter is periodically modified based on a closed loop process that monitors the operation of the heating system. This closed loop process provides a heating medium temperature value that is very near the optimum for energy efficiency.

  13. Wave disc engine apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Muller, Norbert; Piechna, Janusz; Sun, Guangwei; Parraga, Pablo-Francisco

    2018-01-02

    A wave disc engine apparatus is provided. A further aspect employs a constricted nozzle in a wave rotor channel. A further aspect provides a sharp bend between an inlet and an outlet in a fluid pathway of a wave rotor, with the bend being spaced away from a peripheral edge of the wave rotor. A radial wave rotor for generating electricity in an automotive vehicle is disclosed in yet another aspect.

  14. Multicusp plasma containment apparatus

    International Nuclear Information System (INIS)

    Limpaecher, R.

    1980-01-01

    It has been discovered that plasma containment by a chamber having multi-pole magnetic cusp reflecting walls in combination with electronic injection for electrostatic containment provides the means for generating magnetic field free quiescent plasmas for practical application in ion-pumps, electronic switches, and the like. 1250 ''alnico v'' magnets 1/2 '' X 1/2 '' X 1 1/2 '' provide containment in one embodiment. Electromagnets embodying toroidal funneling extend the principle to fusion apparatus

  15. Medical radiological apparatus

    International Nuclear Information System (INIS)

    1980-01-01

    With the apparatus described, images can be obtained by rotation scanning and the image formation from a three dimensional image matrix is converted into an overall picture. Detectors for both X-ray radiation and γ radiation are present and these consist of a row of detector elements, from each of which a separate read-out can be obtained. Therefore both X-ray and γ ray images emitted from the examined object can be obtained. (Th.P.)

  16. Powder collection apparatus/method

    Science.gov (United States)

    Anderson, I.E.; Terpstra, R.L.; Moore, J.A.

    1994-01-11

    Device for separating and collecting ultrafine atomized powder from the gas stream of a gas atomizing apparatus comprises a housing having an interior wall oriented at an angle relative to horizontal so as to form a downwardly converging, conical expansion chamber, an inlet conduit communicated to the expansion chamber proximate an upper region thereof for receiving the gas stream, and an outlet proximate a lower region of the expansion chamber. The inlet conduit is oriented at a compound inclined angle (with respect to horizontal) selected to promote separation and collection of powder from the gas stream in the expansion chamber. The compound angle comprises a first entrance angle that is greater than the angle of repose of the powder on the housing interior wall such that any powder accumulation in the inlet conduit tends to flow down the wall toward the outlet. The second angle is selected generally equal to the angle of the housing interior wall measured from the same horizontal plane so as to direct the gas stream into the expansion chamber generally tangent to the housing interior wall to establish a downward swirling gas stream flow in the expansion chamber. A powder collection container is communicated to the outlet of the expansion chamber to collect the powder for further processing. 4 figures.

  17. Perspectives on Golgi apparatus form and function.

    Science.gov (United States)

    Mollenhauer, H H; Morré, D J

    1991-01-01

    into the cytoplasm presumably have other functions, but these, like the tubules themselves, have only rarely been accommodated into functional models of Golgi apparatus dynamics in secretion or membrane flow.

  18. Informationization nuclear apparatus communication technique

    International Nuclear Information System (INIS)

    Yu Tiqi; Fang Zongliang; Wen Qilin

    2006-01-01

    The paper explains the request of communication ability in nuclear technique application area. Based on the actuality of nuclear apparatus communication ability, and mainly combining with the development of communication technique, the authors analyzes the application trend of communication technique applying in nuclear apparatus, for the apparatus and system needing communication ability, they need selecting suitable communication means to make them accomplish the task immediately and effectively. (authors)

  19. Pellet inspection apparatus

    Science.gov (United States)

    Wilks, Robert S.; Taleff, Alexander; Sturges, Jr., Robert H.

    1982-01-01

    Apparatus for inspecting nuclear fuel pellets in a sealed container for diameter, flaws, length and weight. The apparatus includes, in an array, a pellet pick-up station, four pellet inspection stations and a pellet sorting station. The pellets are delivered one at a time to the pick-up station by a vibrating bowl through a vibrating linear conveyor. Grippers each associated with a successive pair of the stations are reciprocable together to pick up a pellet at the upstream station of each pair and to deposit the pellet at the corresponding downstream station. The gripper jaws are opened selectively depending on the state of the pellets at the stations and the particular cycle in which the apparatus is operating. Inspection for diameter, flaws and length is effected in each case by a laser beam projected on the pellets by a precise optical system while each pellet is rotated by rollers. Each laser and its optical system are mounted in a container which is free standing on a precise surface and is provided with locating buttons which engage locating holes in the surface so that each laser and its optical system is precisely set. The roller stands are likewise free standing and are similarly precisely positioned. The diameter optical system projects a thin beam of light which scans across the top of each pellet and is projected on a diode array. The fl GOVERNMENT CONTRACT CLAUSE The invention herein described was made in the course of or under a contract or subcontract thereunder with the Department of Energy bearing No. EY-67-14-C-2170.

  20. Thermal stir welding apparatus

    Science.gov (United States)

    Ding, R. Jeffrey (Inventor)

    2011-01-01

    A welding method and apparatus are provided for forming a weld joint between first and second elements of a workpiece. The method includes heating the first and second elements to form an interface of material in a plasticized or melted state interface between the elements. The interface material is then allowed to cool to a plasticized state if previously in a melted state. The interface material, while in the plasticized state, is then mixed, for example, using a grinding/extruding process, to remove any dendritic-type weld microstructures introduced into the interface material during the heating process.

  1. Nitrogen fixation apparatus

    Science.gov (United States)

    Chen, Hao-Lin

    1984-01-01

    A method and apparatus for achieving nitrogen fixation includes a volumetric electric discharge chamber. The volumetric discharge chamber provides an even distribution of an electron beam, and enables the chamber to be maintained at a controlled energy to pressure (E/p) ratio. An E/p ratio of from 5 to 15 kV/atm of O.sub.2 /cm promotes the formation of vibrationally excited N.sub.2. Atomic oxygen interacts with vibrationally excited N.sub.2 at a much quicker rate than unexcited N.sub.2, greatly improving the rate at which NO is formed.

  2. Compression test apparatus

    Science.gov (United States)

    Shanks, G. C. (Inventor)

    1981-01-01

    An apparatus for compressive testing of a test specimen may comprise vertically spaced upper and lower platen members between which a test specimen may be placed. The platen members are supported by a fixed support assembly. A load indicator is interposed between the upper platen member and the support assembly for supporting the total weight of the upper platen member and any additional weight which may be placed on it. Operating means are provided for moving the lower platen member upwardly toward the upper platen member whereby an increasing portion of the total weight is transferred from the load indicator to the test specimen.

  3. DNA Sequencing apparatus

    Science.gov (United States)

    Tabor, Stanley; Richardson, Charles C.

    1992-01-01

    An automated DNA sequencing apparatus having a reactor for providing at least two series of DNA products formed from a single primer and a DNA strand, each DNA product of a series differing in molecular weight and having a chain terminating agent at one end; separating means for separating the DNA products to form a series bands, the intensity of substantially all nearby bands in a different series being different, band reading means for determining the position an This invention was made with government support including a grant from the U.S. Public Health Service, contract number AI-06045. The U.S. government has certain rights in the invention.

  4. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    Abele, M.

    1983-01-01

    A computerized tomographic scanning apparatus suitable for diagnosis and for improving target identification in stereotactic neurosurgery is described. It consists of a base, a source of penetrating energy, a detector which produces scanning signals and detector positioning means. A frame with top and bottom arms secures the detector and source to the top and bottom arms respectively. A drive mechanism rotates the frame about an axis along which the frame may also be moved. Finally, the detector may be moved relative to the bottom arm in a direction contrary to the rotation of the frame. (U.K.)

  5. CRANE POSITIONING APPARATUS

    Science.gov (United States)

    Landsiedel, F.W.; Wolff, H.

    1960-06-28

    An apparatus is described for automatically accomplishing the final accurate horizontal positioning of a crane after the latter has been placed to within 1/8 in. of its selected position. For this purpose there is provided a tiltable member on the crane mast for lowering into contact with a stationary probe. Misalignment of the tiltable member, with respect to the probe as the member is lowered, causes tilting of the latter to actuate appropriate switches that energize motors for bringing the mast into proper position. When properly aligned the member is not tilted and a central switch is actuated to indicate the final alignment of the crane.

  6. Control rod testing apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Gaunt, R.R.; Ashman, C.M.

    1987-06-02

    A control rod testing apparatus is described comprising: a first guide means having a vertical cylindrical opening for grossly guiding a control rod; a second guide means having a vertical cylindrical opening for grossly guiding a control rod. The first and second guide means are supported at axially spaced locations with the openings coaxial; and a substantially cylindrical subassembly having a vertical cylindrical opening therethrough. The subassembly is trapped coaxial with and between the first and second guide means, and the subassembly radially floats with respect to the first and second guide means.

  7. Apparatus for chemical synthesis

    Science.gov (United States)

    Kong, Peter C [Idaho Falls, ID; Herring, J Stephen [Idaho Falls, ID; Grandy, Jon D [Idaho Falls, ID

    2011-05-10

    A method and apparatus for forming a chemical hydride is described and which includes a pseudo-plasma-electrolysis reactor which is operable to receive a solution capable of forming a chemical hydride and which further includes a cathode and a movable anode, and wherein the anode is moved into and out of fluidic, ohmic electrical contact with the solution capable of forming a chemical hydride and which further, when energized produces an oxygen plasma which facilitates the formation of a chemical hydride in the solution.

  8. APPARATUS FOR ARC WELDING

    Science.gov (United States)

    Lingafelter, J.W.

    1960-04-01

    An apparatus is described in which a welding arc created between an annular electrode and a workpiece moves under the influence of an electromagnetic field about the electrode in a closed or annular path. This mode of welding is specially suited to the enclosing of nuclear-fuel slugs in a protective casing. For example, a uranium slug is placed in an aluminum can, and an aluminum closure is welded to the open end of the can along a closed or annular path conforming to the periphery of the end closure.

  9. Control rod testing apparatus

    International Nuclear Information System (INIS)

    Gaunt, R.R.; Ashman, C.M.

    1987-01-01

    A control rod testing apparatus is described comprising: a first guide means having a vertical cylindrical opening for grossly guiding a control rod; a second guide means having a vertical cylindrical opening for grossly guiding a control rod. The first and second guide means are supported at axially spaced locations with the openings coaxial; and a substantially cylindrical subassembly having a vertical cylindrical opening therethrough. The subassembly is trapped coaxial with and between the first and second guide means, and the subassembly radially floats with respect to the first and second guide means

  10. Remote docking apparatus

    International Nuclear Information System (INIS)

    Dent, T.H.; Sumpman, W.C.; Wilhelm, J.J.

    1981-01-01

    The remote docking apparatus comprises a support plate with locking devices mounted thereon. The locking devices are capable of being inserted into tubular members for suspending the support plate therefrom. A vertical member is attached to the support plate with an attachment mechanism attached to the vertical member. A remote access manipulator is capable of being attached to the attachment mechanism so that the vertical member can position the remote access manipulator so that the remote access manipulator can be initially attached to the tubular members in a well defined manner

  11. Radiographic scanner apparatus

    International Nuclear Information System (INIS)

    Wake, R.H.

    1980-01-01

    The preferred embodiment of this invention includes a hardware system, or processing means, which operates faster than software. Moreover the computer needed is less expensive and smaller. Radiographic scanner apparatus is described for measuring the intensity of radiation after passage through a planar region and for reconstructing a representation of the attenuation of radiation by the medium. There is a source which can be rotated, and detectors, the output from which forms a data line. The detectors are disposed opposite the planar region from the source to produce a succession of data lines corresponding to the succession of angular orientations of the source. There is a convolver means for convolving each of these data lines, with a filter function, and a means of processing the convolved data lines to create the representation of the radiation attenuation in the planar region. There is also apparatus to generate a succession of data lines indicating radiation attenuation along a determinable path with convolver means. (U.K.)

  12. Percussive arc welding apparatus

    Science.gov (United States)

    Hollar, Jr., Donald L.

    2002-01-01

    A percussive arc welding apparatus includes a generally cylindrical actuator body having front and rear end portions and defining an internal recess. The front end of the body includes an opening. A solenoid assembly is provided in the rear end portion in the internal recess of the body, and an actuator shaft assembly is provided in the front end portion in the internal recess of the actuator body. The actuator shaft assembly includes a generally cylindrical actuator block having first and second end portions, and an actuator shaft having a front end extending through the opening in the actuator body, and the rear end connected to the first end portion of the actuator block. The second end portion of the actuator block is in operational engagement with the solenoid shaft by a non-rigid connection to reduce the adverse rebound effects of the actuator shaft. A generally transversely extending pin is rigidly secured to the rear end of the shaft. One end of the pin is received in a slot in the nose housing sleeve to prevent rotation of the actuator shaft during operation of the apparatus.

  13. Apparatus for gamma radiography

    International Nuclear Information System (INIS)

    1983-06-01

    The aim of the present standard is to fix the rules for the construction of gamma radiography instrumentation without prejudice to the present regulations. These apparatus have to be fitted with only sealed sources conformable to the experimental standard M 61-002. The present standard agrees with the international standard ISO 3999 of 1977 dealing with the same subject. Nevertheless, it is different on the three main following points: it does not accept the same limits of absorbed dose rates in the air calculated on the external surface of projectors; it precribes tightness, bending, crushing and tensile tests for some components of the gamma radiography it prescribes tests of endurance and resistance to breaking for the locking systems of the gamma radiography apparatus. The present standard also specifies the following points: symbols and indications to put on projectors and on the source-holder; identification of the source contained in the projector; and, accompanying documents. The regulation references are given in annexe [fr

  14. Preferred states of the apparatus

    Indian Academy of Sciences (India)

    Abstract. A simple one-dimensional model for the system–apparatus interaction is analysed. The system is a spin-1/2 particle, and its position and momentum degrees constitute the apparatus. An analysis involving only unitary Schrödinger dynamics illustrates the nature of the correlations established in the ...

  15. Cask handling method and apparatus

    International Nuclear Information System (INIS)

    Yoli, A.H.; Husain, I.

    1977-01-01

    The method of transferring radioactive material into and out of the cask comprises positioning a tank with an open end in a well. Then a cask having a passage for moving radioactive material into and out of the cask is placed in the tank through the opening in the tank. The tank opening is then sealed to the cask relative to the well without sealing the passage relative to the well to prevent water filled into the well from leaking into the tank. Then the well is filled with water above the seal, and radioactive material is then moved through the water in the well through the passage into the cask. The tank may be filled with demineralized water from a separate source to pressurize the space in the tank on the other side of the seal from the well to prevent water in the well from entering the tank. The water level in the well and in the tank is then lowered, the tank opening to the cask seal is removed, and a cover is attached to the cask passage to maintain the radioactive material and contaminated water in the cask. The apparatus which accomplishes the above method comprises a tank in a well for receiving a cask therein. A seal between the tank and the cask prevents water in the well from flowing into the tank about the cask and permits water in the well to flow through the cask opening into the cask. A first water supply means raises and lowers the water level in the well, and a second water supply means supplies clean demineralized water to the tank under pressure to prevent water in the well from leaking into the tank. The seal is annularly shaped and is attached to the top of the tank. The central portion of the annular seal is aligned with the cask opening and it has means to seal the annular seal to the cask

  16. Ventilation system for 99Mo production apparatus

    International Nuclear Information System (INIS)

    Izumo, Mishiroku; Okane, Shougo; Sorita, Takami; Aoyama, Saburou

    1978-04-01

    In production of 20 Ci 99 Mo from 235 U fission, about 120 Ci of radioiodine ( 131 I, 132 I, and 133 I) is involved. To remove airborne radioiodine from the exhaust air from production apparatus and minimize radioiodine release to the atmosphere, the ventilation system is equipped with 2 units of Model-FD charcoal filter (KI 3 -Impregnated charcoal 2 inch thick of Barnebey-Cheney Co.). From September 1976 to December 1977, 21 runs of 99 Mo production involving airborne radioiodine were carried out. The ventilation system was operated continuously for the whole 15 months period; variation in removal efficiency of airborne radioiodine from the exhaust air stream was observed. In the runs valuable experiences were gained in operation and maintenance of the ventilation system including activated charcoal filter and health-physics management of such facility. Following are the results: (1) Airborne radioiodine from 99 Mo production apparatus is reduced to 10 -3 % of the original quantity. (2) When the ventilation system is operated at a maximum air flow rate through the filter, the average efficiency during 15 months is over 98%. (3) Airborne radioiodine released from 99 Mo production apparatus to the ventilation system is less than 5% particulate iodine and alkyl iodines and more than 95% inorganic iodine. (4) Airborne radioiodine released from the stack is less than 28 μCi/run, which is below the limit in regulations on Radioisotope Production Laboratory. (auth.)

  17. Apparatus for delivering and receiving radioactive gas

    International Nuclear Information System (INIS)

    Dansky, B.; Epifano, L.; Farella, R.

    1980-01-01

    An apparatus for delivering and receiving gas to and from a patient, such as for lung ventilation studies. In accordance with the invention there is provided a restrictive breathing chamber adapted for coupling to the patient's breathing organs. A system, including a first check valve, is provided for coupling the breathing chamber to an inflatable gas receptacle so as to allow flow only toward the inflatable gas receptacle. Active gas input apparatus, including a second check valve, is also coupled to the breathing chamber, the second check valve allowing flow only toward the breathing chamber means. First and second auxiliary tubes and a gas filter are also provided. A system is provided for coupling the first auxiliary tube from the inflatable receptacle through the gas filter and to an ambient air environment. The second auxiliary tube is coupled from the inflatable receptacle to an ambient air environment. Finally, a gas pump is switchably coupled as between the first and second auxiliary tubes and operative to selectively cause gas flow in the first auxiliary tube toward the ambient environment, and in the second auxiliary tube toward the inflatable receptacle. A gas trap structure is also disclosed

  18. Archimedes force on Casimir apparatus

    Directory of Open Access Journals (Sweden)

    Shevchenko V.

    2016-01-01

    Full Text Available The talk addresses a problem of Casimir apparatus in weak gravitational field, surrounded by a dense medium. The falling of the apparatus has to be governed by the equivalence principle, taking into account proper contributions to the weight of the apparatus from its material part and from distorted quantum fields. We discuss general ex pression for the corresponding force in terms of the effective action. By way of example we compute explicit expression for Archimedes force, acting on the Casimir apparatus of finite size, immersed into thermal bath of free scalar field. It is shown that besides universal term, proportional to the volume of the apparatus, there are non-universal quantum corrections, depending on the boundary conditions.

  19. Flexible ultrasonic pipe inspection apparatus

    Science.gov (United States)

    Jenkins, Charles F.; Howard, Boyd D.

    1998-01-01

    A flexible, modular ultrasonic pipe inspection apparatus, comprising a flexible, hollow shaft that carries a plurality of modules, including at least one rotatable ultrasonic transducer, a motor/gear unit, and a position/signal encoder. The modules are connected by flexible knuckle joints that allow each module of the apparatus to change its relative orientation with respect to a neighboring module, while the shaft protects electrical wiring from kinking or buckling while the apparatus moves around a tight corner. The apparatus is moved through a pipe by any suitable means, including a tether or drawstring attached to the nose or tail, differential hydraulic pressure, or a pipe pig. The rotational speed of the ultrasonic transducer and the forward velocity of the apparatus are coordinated so that the beam sweeps out the entire interior surface of the pipe, enabling the operator to accurately assess the condition of the pipe wall and determine whether or not leak-prone corrosion damage is present.

  20. Cellular mechanisms within the juxtaglomerular apparatus

    DEFF Research Database (Denmark)

    Briggs, J P; Skøtt, O; Schnermann, J

    1990-01-01

    Cl concentration at the macular densa. This change also results in inhibition of secretion of renin. The macula densa has a unique location near the terminal end of the thick ascending limb, where NaCl concentration is highly flow dependent. The cellular mechanisms by which changes in tubular fluid NaCl produce...... vasoconstriction and inhibition of renin secretion are unknown, but the anatomy of the juxtaglomerular apparatus strongly suggests that such responses may be mediated by the extraglomerular mesangial cells located in the polar cushion underlying the macula densa. Recent evidence suggests that interstitial chloride...

  1. Radioactive waste treatment apparatus

    International Nuclear Information System (INIS)

    Abrams, R.F.; Chellis, J.G.

    1983-01-01

    Radioactive waste treatment apparatus is disclosed in which the waste is burned in a controlled combustion process, the ash residue from the combustion process is removed and buried, the gaseous effluent is treated in a scrubbing solution the pH of which is maintained constant by adding an alkaline compound to the solution while concurrently extracting a portion of the scrubbing solution, called the blowdown stream. The blowdown stream is fed to the incinerator where it is evaporated and the combustibles in the blowdown stream burned and the gaseous residue sent to the scrubbing solution. Gases left after the scrubbing process are treated to remove iodides and are filtered and passed into the atmosphere

  2. Radioactive aerosol inhalation apparatus

    International Nuclear Information System (INIS)

    Bordoni, M.E.; Lieberman, E.

    1987-01-01

    An aerosol inhalation apparatus for supplying an aerosol mist containing radioactive tagged particles to a subject is described comprising a reusable radiation-shielding container having lid means. The contents of the container are readily accessible. A radioactive aerosol inhalation device includes first and second conduit means in the container and passing therethrough, means for communicating with an air passageway of a subject connected to the first and second conduit means externally of the container. Valve means control exhalation from the second conduit means. A nebulizer is within the container connected to the first conduit means. Means are positioned at least in part within the container and in fluid communication with the nebulizer for allowing introduction of radioactive solution from outside the container into the nebulizer

  3. Spine immobilization apparatus

    Science.gov (United States)

    Lambson, K. H.; Vykukal, H. C. (Inventor)

    1981-01-01

    The apparatus makes use of a normally flat, flexible bladder filled with beads or micro-balloons that form a rigid mass when the pressure within the bladder is decreased below ambient through the use of a suction pump so that the bladder can be conformed to the torso of the victim and provide the desired restraint. The bladder is strapped to the victim prior to being rigidified by an arrangement of straps which avoid the stomach area. The bladder is adapted to be secured to a rigid support, i.e., a rescue chair, so as to enable removal of a victim after the bladder has been made rigid. A double sealing connector is used to connect the bladder to the suction pump and a control valve is employed to vary the pressure within the bladder so as to soften and harden the bladder as desired.

  4. Multichannel Thomson scattering apparatus

    International Nuclear Information System (INIS)

    Bretz, N.; Dimock, D.; Foote, V.; Johnson, D.; Long, D.; Tolnas, E.

    1977-07-01

    A Thomson scattering apparatus for measuring the electron temperature and density along a 90 cm diameter of the PLT plasma has been built. A wide angle objective images the 3 mm x 900 mm ruby laser beam onto an image dissector which rearranges the 300 : 1 image to 20 : 1 forming the input slit of a spectrometer. The stigmatic spectrometer provides 20 wavelength elements of approximately 70 A each. A micro-channel-plate image intensifier optically coupled to a cooled SIT tube provides detection with single frame linearity and 1000 : 1 dynamic range. Spatial profiles of N/sub e/ and T/sub e/ in the range 10 13 - 10 14 cm -3 and 0.05 - 3 keV have an accuracy of 30 √10 13 /N/sub e/ (cm -3 ) percent per 1.2 cm element

  5. Exhaust gas circulation apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Shibano, K.

    1975-01-10

    An exhaust gas recirculation apparatus is described. An exhaust gas recirculation tube is connected between the exhaust pipe and the intake tube and the opening of the tube; the amount of recirculated gas is regulated by a piston-type cycle control valve which is connected to the throttle valve of the carburetor through an arm. The arm is designed in a two-step linkage so that the cycle valve closes the recirculation tube when the throttle valve is at a fully opened angle and a small angle. Therefore, no exhaust gas recirculation occurs when the automobile is in full power, idling, or low running conditions. This prevents lowered engine power at these conditions.

  6. Apparatus for stereotactic surgery

    International Nuclear Information System (INIS)

    Koslow, M.A.M.

    1982-01-01

    Apparatus for stereotactic surgery consisting of a probe and a computerized tomographic scanning system is described. The scanning system comprises a display and means for reconstructing cross-sectional images on the display using data from partial circumferential scans of source and detectors. It operates on the data with an algorithm that provides the difference between the local values of the linear attenuation coefficient and average of these values within a circle centered at each reconstruction point. The scanning system includes a means of maintaining the frames of reference of the probe and scanning system rigid with respect to one another. The position of the probe, which may be a cryogenic probe, with respect to the actual anatomical structure of the body, particularly a human head, may thus be viewed by the surgeon. (author)

  7. Vortex Apparatus and Demonstrations

    Science.gov (United States)

    Shakerin, Said

    2010-01-01

    Vortex flow, from millimeter to kilometer in scale, is important in many scientific and technological areas. Examples are seen in water strider locomotion, from industrial pipe flow (wastewater treatment) to air traffic control (safe distance between aircrafts on a runway ready for takeoff) to atmospheric studies. In this paper, we focus on a…

  8. Apparatus for the automatic determination of oxygen consumption in ...

    African Journals Online (AJOL)

    An apparatus is described which permits the automatic determination of the oxygen consumption of three fish and a control for 24 hours per day. This is made possible by an electrical control system operating four three-way valves which allow water from one of four respiration chambers at a time to flow past an oxygen ...

  9. Palladium on Carbon-Catalyzed Suzuki-Miyaura Coupling Reaction Using an Efficient and Continuous Flow System

    Directory of Open Access Journals (Sweden)

    Tomohiro Hattori

    2015-01-01

    Full Text Available The continuous flow Suzuki-Miyaura reaction between various haloarenes and arylboronic acids was successfully achieved within only ca. 20 s during the single-pass through a cartridge filled with palladium on carbon (Pd/C. No palladium leaching was observed in the collected reaction solution by atomic absorption spectrometry (detection limit: 1 ppm.

  10. Experimental apparatus to test air trap valves

    Energy Technology Data Exchange (ETDEWEB)

    Lemos De Lucca, Y de F [CTH-DAEE-USP/FAAP/UNICAMP (Brazil); Aquino, G A de [SABESP/UNICAMP (Brazil); Filho, J G D, E-mail: yvone.lucca@gmail.co [Water Resources Department, University of Campinas-UNICAMP, Av. Albert Einstein, 951, Cidade Universitaria-Barao Geraldo-Campinas, S.P., 13083-852 (Brazil)

    2010-08-15

    It is known that the presence of trapped air within water distribution pipes can lead to irregular operation or even damage to the distribution systems and their components. The presence of trapped air may occur while the pipes are being filled with water, or while the pumping systems are in operation. The formation of large air pockets can produce the water hammer phenomenon, the instability and the loss of pressure in the water distribution networks. As a result, it can overload the pumps, increase the consumption of electricity, and damage the pumping system. In order to avoid its formation, all of the trapped air should be removed through 'air trap valves'. In Brazil, manufacturers frequently have unreliable sizing charts, which cause malfunctioning of the 'air trap valves'. The result of these malfunctions causes accidents of substantial damage. The construction of a test facility will provide a foundation of technical information that will be used to help make decisions when designing a system of pipelines where 'air trap valves' are used. To achieve this, all of the valve characteristics (geometric, mechanic, hydraulic and dynamic) should be determined. This paper aims to describe and analyze the experimental apparatus and test procedure to be used to test 'air trap valves'. The experimental apparatus and test facility will be located at the University of Campinas, Brazil at the College of Civil Engineering, Architecture, and Urbanism in the Hydraulics and Fluid Mechanics laboratory. The experimental apparatus will be comprised of various components (pumps, steel pipes, butterfly valves to control the discharge, flow meter and reservoirs) and instrumentation (pressure transducers, anemometer and proximity sensor). It should be emphasized that all theoretical and experimental procedures should be defined while taking into consideration flow parameters and fluid properties that influence the tests.

  11. Radiation measuring apparatus

    International Nuclear Information System (INIS)

    DiIanni, E.J.; Cooley, H.J.; Fujita, M.; Noback, C.V.

    1986-01-01

    This patent describes an apparatus for measuring radiation field strength comprising in combination, (a) biased potential radiation detector having an output circuit, the detector being of the type that is effective when biased to respond to impingement of radiation by generating an output pulse at its output circuit, and when not biased being ineffective to generate an output pulse when impinged by radiation, (b) biasing means operatively coupled to the radiation detector for selectively biasing the radiation detector to generate an output pulse in response to impingement by radiation, (c) time counting means including timing control means operable to start and terminate time counting, the radiation detector output circuit being operatively coupled to the time counting means and being effective upon generation of an output pulse to cause the time counting means to terminate time counting, (d) master control means operatively coupled to (1) the biasing means to selectively cause the biasing means to bias the radiation detector to respond to impingement by radiation, (2) the time counting means and effective to cause the time counting means to start time counting simultaneously with the operative biasing of the radiation detector, the master control means receiving a signal when the radiation detector generates an output pulse

  12. Nuclear fusion apparatus

    International Nuclear Information System (INIS)

    Nagata, Daizaburo; Yamada, Masao.

    1974-01-01

    Object: To provide a nuclear fusion apparatus in which a magnetic limiter is disposed within a vacuum vessel, said magnetic limiter being supported in such a manner so as to not to exert mechanical action upon said vacuum vessel, thereby minimizing a force applied to the vacuum vessel to easily manufacture the vacuum vessel. Structure: The magnetic limiter disposed within the vacuum vessel is connected to one end of a supporting post which extends through the wall of the vacuum vessel through a seal portion, the other end of the supporting post being secured to a structure such as a house outside the vacuum vessel. The seal portion comprises a bellows of high spring elasticity mounted on the vacuum vessel and a seal element comprised of an electric insulator such as ceramic for connecting the bellows to the supporting post, the supporting post extending through the wall of the vacuum vessel in vacuum-tight fashion, the force applied to the magnetic limiter exerting no influence upon the vacuum vessel. (Kamimura, M.)

  13. Apparatus for internal irradiation

    International Nuclear Information System (INIS)

    Hooft, E.V.

    1980-01-01

    Apparatus for internal irradiation wherein the radioactive material is applied in the shape of a ball row consisting of contiguous radioactive and neutral balls. This ball row is prepared beforehand and is pneumatically transferred to an applicator tube adapted to be introduced into a body cavity. In order that the balls may stay exactly in the right places during the irradiation, the applicator tube is provided with an internal channel having a narrow end portion, passing through a shoulder into the remaining wider portion, and a final ball is added to each ball row, this final ball having a larger diameter than the other balls, so that it is not admitted in the narrow end portion of the internal channel in the applicator tube. Thus, upon introduction of a ball row, the final ball is arrested by the shoulder and keeps the other balls in place. A plurality of applicator tubes may be applied, each of which is associated with an intermediate container in which the ball row is composed. After the irradiation, the ball row is returned through the intermediate container to a sorting device directing the balls to appropriate storage containers. However, the final ball is retained in the intermediate container, so that it may be added to the next ball row to be composed

  14. Controlled nuclear fusion apparatus

    International Nuclear Information System (INIS)

    Bussard, R.W.; Coppi, B.

    1982-01-01

    A fusion power generating device is disclosed having a relatively small and inexpensive core region which may be contained within an energy absorbing blanket region. The fusion power core region contains apparatus of the toroidal type for confining a high density plasma. The fusion power core is removable from the blanket region and may be disposed and/or recycled for subsequent use within the same blanket region. Thermonuclear ignition of the plasma is obtained by feeding neutral fusible gas into the plasma in a controlled manner such that charged particle heating produced by the fusion reaction is utilized to bootstrap the device to a region of high temperatures and high densities wherein charged particle heating is sufficient to overcome radiation and thermal conductivity losses. The high density plasma produces a large radiation and particle flux on the first wall of the plasma core region thereby necessitating replacement of the core from the blanket region from time to time. A series of potentially disposable and replaceable central core regions are disclosed for a large-scale economical electrical power generating plant

  15. Continuous steel production and apparatus

    Science.gov (United States)

    Peaslee, Kent D [Rolla, MO; Peter, Jorg J [McMinnville, OR; Robertson, David G. C. [Rolla, MO; Thomas, Brian G [Champaign, IL; Zhang, Lifeng [Trondheim, NO

    2009-11-17

    A process for continuous refining of steel via multiple distinct reaction vessels for melting, oxidation, reduction, and refining for delivery of steel continuously to, for example, a tundish of a continuous caster system, and associated apparatus.

  16. Cherry-Slush-Candling Apparatus

    Science.gov (United States)

    Stephens, James B.; Weiss, James R.; Hoover, Gordon

    1996-01-01

    Proposed infrared-scanning apparatus for use in bakeries making cherry pies detect cherry pits remaining in cherry slush after pitting process. Pits detected via their relative opacity to infrared radiation.

  17. INFLATE: INFlate Landing Apparatus Technology

    Science.gov (United States)

    Koryanov, V. V. K.; Da-Poian, V. D. P.

    2018-02-01

    Our project, named INFLATE (INFlatable Landing Apparatus Technology), aims at reducing space landing risks and constraints and so optimizing space missions (reducing cost, mass, and risk and in the same time improving performance).

  18. Method and apparatus for the separation of solid particles having different densities

    NARCIS (Netherlands)

    Rem, P.C.; Berkhout, S.P.M.

    2011-01-01

    A method and apparatus for separating solid particles of different densities, using a magnetic process fluid. The solid particles are thoroughly mixed in a small partial flow of the process fluid. The small turbulent partial flow is added to a large laminar partial flow of the process fluid, after

  19. Apparatus Development In Maros

    Directory of Open Access Journals (Sweden)

    H. Aras Solong

    2015-03-01

    Full Text Available ABSTRACT This study aims to identify and describe 1 Development of Administrative through education and training training promotion transfer and rotation and the application of demotion system non-title under Law No. 43 of 1999 on the development of career civil servants based merit system and work performance and Government Regulation No. 101 of 2000 on Education and Training Training for Civil Servants. 2 Revealing differences in work motivation based on the intensity of the education or training training using Herzbergs Two Factor Theory of extrinsic factors hygiene and intrinsic factors motivator that influence employees motivation Maros regency government in carrying out its duties and functions as members civil in public service. This study uses a quantitative approach to date collection techniques through a questionnaire Questionnaire. Informant are civil servants who occupied echelon II III. And IV while the analysis of the date used quantitative analysis to uncover the implementation of personnel development and employees motivation difference Maros region based on the intensity of the education or training training to get job satisfaction in the public service. The results of this study will reveal that 1 Development of Apparatus for improving the knowledge ability professionalism competence skills can work as a reformer change attitude eager to work motivated to do the work get satisfaction in work and getting justice in employment. 2 The difference in work motivation Maros local government employees affected by extrinsic factors hygiene and intrinsic factor motivator is the variable gain high salary H occupies the first ranking while serving the community satisfaction variables M occupy the last ranking. That is that the satisfaction of serving the people affected by the high salaries earned by the employees to do the job.

  20. Apparatus and procedure for determining oil droplet size distribution

    Science.gov (United States)

    Meyer, R. A.; Kirsch, M.; Howard, F.; Freestone, F.

    1982-03-01

    This program was initiated to develop a method and apparatus for determining the oil drop size distribution in flowing oily brine during brine cleanup treatment. An automated photomicrographic apparatus for taking time lapse photographs of oily brine that was briefly at rest is described. This apparatus meets all N.E.C. Class 1, Division 1, Group D requirements for operation where explosive concentrations of hydrocarbons are known to exist. The system demonstrates its ability to determine the size and number distribution of 2 to 100 micrometer spherical entitles, and it establishes their density as well. Thus the technique can differentiate between oil drops, oil covered gas bubbles, and oil covered sand or other solids. The report presents both the techniques for reducing the photomicrographs to size and number data, and the FORTRAN programs involved.

  1. Fuel leak detection apparatus for gas cooled nuclear reactors

    Science.gov (United States)

    Burnette, Richard D.

    1977-01-01

    Apparatus is disclosed for detecting nuclear fuel leaks within nuclear power system reactors, such as high temperature gas cooled reactors. The apparatus includes a probe assembly that is inserted into the high temperature reactor coolant gaseous stream. The probe has an aperture adapted to communicate gaseous fluid between its inside and outside surfaces and also contains an inner tube for sampling gaseous fluid present near the aperture. A high pressure supply of noncontaminated gas is provided to selectively balance the pressure of the stream being sampled to prevent gas from entering the probe through the aperture. The apparatus includes valves that are operable to cause various directional flows and pressures, which valves are located outside of the reactor walls to permit maintenance work and the like to be performed without shutting down the reactor.

  2. Apparatus for diffusion separation

    International Nuclear Information System (INIS)

    Nierenberg, W.A.; Pontius, R.B.

    1976-01-01

    The method of testing the separation efficiency of porous permeable membranes is described which comprises causing a stream of a gaseous mixture to flow into contact with one face of a finely porous permeable membrane under such conditions that a major fraction of the mixture diffuses through the membrane, maintaining a rectangular cross section of the gaseous stream so flowing past said membrane, continuously recirculating the gas that diffuses through said membrane and continuously withdrawing the gas that does not diffuse through said membrane and maintaining the volume of said recirculating gas constant by continuously introducing into said continuously recirculating gas stream a mass of gas equivalent to that which is continuously withdrawn from said gas stream and comparing the concentrations of the light component in the entering gas, the withdrawn gas and the recirculated gas in order to determine the efficiency of said membrane

  3. Flexible ultrasonic pipe inspection apparatus

    Science.gov (United States)

    Jenkins, C.F.; Howard, B.D.

    1998-06-23

    A flexible, modular ultrasonic pipe inspection apparatus, comprises a flexible, hollow shaft that carries a plurality of modules, including at least one rotatable ultrasonic transducer, a motor/gear unit, and a position/signal encoder. The modules are connected by flexible knuckle joints that allow each module of the apparatus to change its relative orientation with respect to a neighboring module, while the shaft protects electrical wiring from kinking or buckling while the apparatus moves around a tight corner. The apparatus is moved through a pipe by any suitable means, including a tether or drawstring attached to the nose or tail, differential hydraulic pressure, or a pipe pig. The rotational speed of the ultrasonic transducer and the forward velocity of the apparatus are coordinated so that the beam sweeps out the entire interior surface of the pipe, enabling the operator to accurately assess the condition of the pipe wall and determine whether or not leak-prone corrosion damage is present. 7 figs.

  4. Optical fiber stripper positioning apparatus

    Science.gov (United States)

    Fyfe, Richard W.; Sanchez, Jr., Amadeo

    1990-01-01

    An optical fiber positioning apparatus for an optical fiber stripping device is disclosed which is capable of providing precise axial alignment between an optical fiber to be stripped of its outer jacket and the cutting blades of a stripping device. The apparatus includes a first bore having a width approximately equal to the diameter of an unstripped optical fiber and a counter bore axially aligned with the first bore and dimensioned to precisely receive a portion of the stripping device in axial alignment with notched cutting blades within the stripping device to thereby axially align the notched cutting blades of the stripping device with the axis of the optical fiber to permit the notched cutting blades to sever the jacket on the optical fiber without damaging the cladding on the optical fiber. In a preferred embodiment, the apparatus further includes a fiber stop which permits determination of the length of jacket to be removed from the optical fiber.

  5. The Conservation Ideological State Apparatus

    Directory of Open Access Journals (Sweden)

    Jared D Margulies

    2018-01-01

    Full Text Available This article considers Louis Althusser's theory of the ideological state apparatuses (ISAs for advancing political ecology scholarship on the functioning of the state in violent environments. I reflect on a series of events in which a state forest department in South India attempted to recast violent conflicts between themselves and local communities over access to natural resources and a protected area as a debate over human-wildlife conflicts. Through the example of conservation as ideology in Wayanad, Kerala, I show how the ISAs articulate the functioning of ideology within the state apparatuses in order for us to understand the larger mechanics of the state apparatus and the reproduction of the relations of production necessary for the reproduction of capitalism. Revisiting the ISAs as a theoretical framework for studies in political ecology and conservation is timely given the resurgence of militarised conservation tactics, the emancipatory aims of Althusser's theory, and political ecology's turn towards praxis.

  6. Apparatus for control of mercury

    Science.gov (United States)

    Downs, William; Bailey, Ralph T.

    2001-01-01

    A method and apparatus for reducing mercury in industrial gases such as the flue gas produced by the combustion of fossil fuels such as coal adds hydrogen sulfide to the flue gas in or just before a scrubber of the industrial process which contains the wet scrubber. The method and apparatus of the present invention is applicable to installations employing either wet or dry scrubber flue gas desulfurization systems. The present invention uses kraft green liquor as a source for hydrogen sulfide and/or the injection of mineral acids into the green liquor to release vaporous hydrogen sulfide in order to form mercury sulfide solids.

  7. Nuclear fuel pellet loading apparatus

    International Nuclear Information System (INIS)

    Gerkey, K.S.

    1979-01-01

    An automatic apparatus for loading a predetermined amount of nuclear fuel pellets into a nuclear fuel element to be used in a nuclear reactor is described. The apparatus consists of a vibratory bed capable of supporting corrugated trays containing rows of nuclear fuel pellets and arranged in alignment with the open ends of several nuclear fuel elements. A sweep mechanism is arranged above the trays and serves to sweep the rows of fuel pellets onto the vibratory bed and into the fuel element. A length detecting system, in conjunction with a pellet stopping mechanism, is also provided to assure that a predetermined amount of nuclear fuel pellets are loaded into each fuel element

  8. A simple Cavendish experimental apparatus

    Science.gov (United States)

    Kossler, W. J.; Klein, Susann; Morrow, Dominick; Juliao, Andre

    2016-03-01

    A simple Cavendish apparatus is described that allows measurement of the gravitational constant G and makes observable the gravitational attraction between commonplace objects. The apparatus consists of a torsion balance constructed from readily available materials, including lead bricks and fishing weights ("sinkers"). A computer program is used to determine the gravitational field at the location of the small mass due to a nearby lead brick, which allows students to gain experience with numerical methods. Experimental results obtained are compatible with the accepted value of G.

  9. Apparatus for diffusion-gap thermal desalination

    Science.gov (United States)

    Lowenstein, Andrew

    2017-09-26

    A thermal distillation apparatus including evaporation surfaces that are wetted with a solution, and from which at least some of the volatile solvent contained in the solution evaporates, condensers having an external surface in close proximity to, but not touching, a corresponding one of the one or more evaporation surfaces, and on which vapors of the solvent condense, releasing thermal energy that heats a flow of the solution moving upward within the condensers, spacers that prevent contact between the evaporating surfaces and the condensers, wherein spaces between the evaporating surfaces and the condensers are filled with a gaseous mixture composed of solvent vapor and one or more non-condensable gases, and except for diffusion of the solvent vapor relative to the non-condensable gases, the gaseous mixture is stationary.

  10. Lubrication method and apparatus

    Energy Technology Data Exchange (ETDEWEB)

    McCarty, R.S.

    1988-05-03

    In a combustion turbine engine comprising a bearing member journaling a rotatable component, and compressor means providing pressurized air, the method of providing liquid lubricant to the bearing member is described comprising the steps of: providing the liquid lubricant sealed within a collapsible and penetrable bladder member; enclosing the bladder member and lubricant within a substantially closed housing sealingly cooperating with the bladder member to define a pair of chambers; arranging a penetrating lance member in one of the pair of chambers in confronting relationship with the bladder member; providing communication of the pressurized air with the other of the pair of chambers to force the bladder member into impaled sealing relationship with the lance member; communicating the lubricant to the bearing member via the lance member; and utilizing the pressurized air within the other chamber to collapse the bladder member, simultaneously flowing the lubricant to the bearing member.

  11. Calculation of period processing solution syrup in vacuum apparatus

    Directory of Open Access Journals (Sweden)

    A. A. Slavyanskii

    2016-01-01

    Full Text Available Important and crucial element in the management of the technological flow of production of sugar product standards is the period of time the enrichment of massecuite, since its neutralization in the process of crystal formation in vacuum apparatus, excess sugar solution. Although currently proposed and implemented in the industry, including as a front-end accompany the process, a number of ways in the real world sugar production in many cases have to resort to the services of an experienced operator. It is obvious that in any case it is necessary to have a surround-dependent glucose solution data on time for the excess sugar solution into the vacuum apparatus. With regard to the period of the enrichment of depleted sucrose solution are entered into this substance excess sucrose solution, it should be noted that this problem is theoretically still insufficiently developed. It is obvious that for practical purposes it is desirable to have a simple and convenient for engineering calculation of sugar processing time dependencies of the specified volume of water from the operating parameters of the process (the required concentration of sucrose, temperature of the solution stirring. The problem is the quantitative analysis of sucrose crystallization in vacuum apparatus, including the timing of enrichment solution to the excess syrup, period of time processing massecuite total this apparatus has been investigated in many works. However, due to its importance to the task of obtaining commercial sugar high standards this issue required further in-depth examination. In the article to support the enrichment process solution sucrose due to neutralize this solvent system in vacuum apparatus, from the standpoint of diffusion theory provides a more reasonable compared to known so far, quantitative analysis of this process. Where as sucrose crystals team are considering a system of balls, uniformly distributed in vacuum apparatus. On the basis of the solution

  12. Flexible ultrasonic pipe inspection apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, C.F.; Howard, B.D.

    1994-01-01

    Pipe crawlers, pipe inspection {open_quotes}rabbits{close_quotes} and similar vehicles are widely used for inspecting the interior surfaces of piping systems, storage tanks and process vessels for damaged or flawed structural features. This paper describes the design of a flexible, modular ultrasonic pipe inspection apparatus.

  13. Nuclear fuel rod loading apparatus

    International Nuclear Information System (INIS)

    King, H.B.

    1981-01-01

    A nuclear fuel loading apparatus, incorporating a microprocessor control unit, is described which automatically loads nuclear fuel pellets into dual fuel rods with a minimum of manual involvement and in a manner and sequence to ensure quality control and accuracy. (U.K.)

  14. Single-pass multi-view volume rendering

    OpenAIRE

    Hübner, T; Pajarola, R

    2007-01-01

    In this paper, we introduce a new direct volume rendering (DVR) algorithm for multi-view auto-stereoscopic displays. Common multi-view methods perform multi-pass rendering (one pass for each view) and subsequent image compositing and masking for generating multiple views. The rendering time increases therefore linearly with the number of views, but sufficient frame-rates are achieved by sub-resolution rendering, at the expense of degraded image quality. To overcome these disadvantages for DVR...

  15. Single pass kernel k-means clustering method

    Indian Academy of Sciences (India)

    2016-08-26

    Aug 26, 2016 ... Department of Computer Science and Engineering, Srinivasa Ramanujan Institute of Technology, Anantapur 515701, India; Department of Computer Science and Engineering, Rajeev Gandhi Memorial College of Engineering and Technology, Nandyal 518501, India; Department of Computer Science and ...

  16. Single pass kernel k-means clustering method

    Indian Academy of Sciences (India)

    In unsupervised classification, kernel -means clustering method has been shown to perform better than conventional -means clustering method in ... 518501, India; Department of Computer Science and Engineering, Jawaharlal Nehru Technological University, Anantapur College of Engineering, Anantapur 515002, India ...

  17. Single pass kernel k-means clustering method

    Indian Academy of Sciences (India)

    easily implemented and is suitable for large data sets, like those in data mining appli- cations. Experimental results show that, with a small loss of quality, the proposed method can significantly reduce the time taken than the conventional kernel k-means cluster- ing method. The proposed method is also compared with other ...

  18. Single pass kernel k-means clustering method

    Indian Academy of Sciences (India)

    This approach has reduced both time complexity and memory requirements. However, the clustering result of this method will be very much deviated form that obtained using the conventional kernel k-means method. This is because of the fact that pseudo cluster centers in the input space may not represent the exact cluster ...

  19. Single Pass Collider Memo: Gradient Perturbations of the SLC arc

    Energy Technology Data Exchange (ETDEWEB)

    Weng, W.T.; Sands, M.; /SLAC

    2016-12-16

    As the beam passes through the arcs, the gradient it encounters at each magnet differs from the design value. This deviation may be in part random and in part systematic. In this note we make estimates of the effects to be expected from both kinds of errors.

  20. Assessment of disintegration of rapidly disintegrating tablets by a visiometric liquid jet-mediated disintegration apparatus.

    Science.gov (United States)

    Desai, Parind M; Liew, Celine V; Heng, Paul W S

    2013-02-14

    The aim of this study was to develop a responsive disintegration test apparatus that is particularly suitable for rapidly disintegrating tablets (RDTs). The designed RDT disintegration apparatus consisted of disintegration compartment, stereomicroscope and high speed video camera. Computational fluid dynamics (CFD) was used to simulate 3 different designs of the compartment and to predict velocity and pressure patterns inside the compartment. The CFD preprocessor established the compartment models and the CFD solver determined the numerical solutions of the governing equations that described disintegration medium flow. Simulation was validated by good agreement between CFD and experimental results. Based on the results, the most suitable disintegration compartment was selected. Six types of commercial RDTs were used and disintegration times of these tablets were determined using the designed RDT disintegration apparatus and the USP disintegration apparatus. The results obtained using the designed apparatus correlated well to those obtained by the USP apparatus. Thus, the applied CFD approach had the potential to predict the fluid hydrodynamics for the design of optimal disintegration apparatus. The designed visiometric liquid jet-mediated disintegration apparatus for RDT provided efficient and precise determination of very short disintegration times of rapidly disintegrating dosage forms. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. An apparatus for submerged gel electrophoresis.

    Science.gov (United States)

    Kozulić, B; Heimgartner, U

    1991-11-01

    A novel apparatus for submerged gel electrophoresis is described in detail. It includes an upper buffer compartment, a lower buffer compartment, and a horizontal plate between the two compartments. The horizontal plate is a heat exchanger connected to an external heater/cooler. Buffer circulates between the two compartments through openings in the horizontal plate. In the upper compartment two separated openings are positioned on each side of the horizontal plate between the side walls and long vertical barriers. The barriers initially direct the flow of buffer and define the electric field on the sides of the upper compartment. The electric field is confined essentially into a rectangular box, defined on the ends by the end walls, on the sides by the barriers, on the bottom by the cooling plate, and on the top by the air. Since the volume of buffer is smaller in the electrode compartment than in the reservoir under the cooling plate, this design enables formation of a substantially uniform electric field without creating too high a current. To enhance uniformity of the electric field, anode and cathode consist each of two platinum wires positioned one above the other at a distance of 6 mm. The electrodes can be placed parallel to the sides and perpendicular to the buffer flow or parallel to the ends and the flow of buffer. The stream of buffer in the upper compartment is regulated by two dams, perpendicular to the long barriers, on each end of the horizontal plate.(ABSTRACT TRUNCATED AT 250 WORDS)

  2. Apparatus for assembly of microelectronic devices

    Science.gov (United States)

    Okandan, Murat; Nielson, Gregory N.; Cruz-Campa, Jose Luis; Lavin, Judith Maria; Resnick, Paul J.

    2017-09-12

    An apparatus including a carrier substrate configured to move a microelectronic device. The apparatus further includes a rotatable body configured to receive the microelectronic device. Additionally, the apparatus includes a second substrate configured to receive the microelectronic device from the rotatable body.

  3. Nuclear reactor apparatus

    International Nuclear Information System (INIS)

    Braun, H.E.; Bonnet, H.P.

    1978-01-01

    The reactor and its containment, instead of being supported on a solid concrete pad, are supported on a truss formed of upper and lower reinforced horizontal plates and vertical walls integrated into a rigid structure. The plates and walls from chambers within which the auxiliary components of the reactor, such as valves, pumping equipment and various tanks, are disposed. Certain of the chambers are also access passages for personnel, pipe chases, valve chambers and the like. In particular the truss includes an annular chamber. This chamber is lined and sealed by a corrosion-resistant liner and contains coolant and serves as a refueling cooling storage tank. This tank is directly below the primary-coolant conductor loops which extend from the reactor above the upper plate. The upper plate includes a sump connected to the tank through which coolant flows into the tank in the event of the occurrence of a loss-of-coolant accident. The truss extends beyond the containment and has chambers in the extending annulus. Pumps for circulating the coolant between the refueling coolant storage tank and the reactor are provided in certain of these chambers. The pumps are connected to the reactor by relatively short coolant conductors. Access to these pumps is readily afforded through hatches in the extending annulus

  4. New apparatus of JMTR hot laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, Haru Yuki; Kawa Mura, Hiro Shi [Japan Atomic Energy Research Institute, Tokai (Japan)

    1995-09-15

    In the Hot Laboratory, PIE apparatus and technology have been continuously developed and expanded to accommodate the needs of researchers. Especially from 1994 to 1995, several apparatus were extensively developed and are being installed as follows: 1)PIE equipment for beryllium examinations To measure the tritium release rate, thermal coefficient and so on of irradiated beryllium, four glove boxes and apparatus were installed. 2)Welding and machining apparatus To evaluate the weldability of fusion reactor materials, plates of SUS 316 and Inconel 625 irradiated in the JMTR were welded, machined to test pieces and then subjected to tensile test. 3)Electron beam heat load testing apparatus To perform high heat load test and thermal shock test for plasma facing materials of fusion reactor, an electron beam heating apparatus was manufactured and installed in a concrete cell. 4)Test piece manufacturing apparatus A cutting apparatus to cut the tube of in pile loop used in the JMTR, and an electro discharge machining apparatus to manufacture the test pieces were installed. 5)IASCC testing apparatus To perform the stress corrosion cracking test in high temperature water, an IASCC testing apparatus was installed and offered many useful data.

  5. Construction of shallow land simulation apparatuses

    International Nuclear Information System (INIS)

    Yamamoto, Tadatoshi; Ohtsuka, Yoshiro; Takebe, Shinichi; Ohnuki, Toshihiko; Ogawa, Hiromichi; Harada, Yoshikane; Saitoh, Kazuaki; Wadachi, Yoshiki

    1984-07-01

    Shallow land simulation apparatuses in which natural soil can be used as testing soil have been constructed to investigate the migration characteristics of radionuclides in a disposal site. These apparatuses consist of aerated zone apparatus and aquifer zone one. In the aerated zone apparatus, aerated soil upon ground water level is contained in the soil column (d: 30cm x h: 120cm). In the aquifer zone apparatus, aquifer soil laying ground water level is contained in the soil vessel (b: 90cm x l: 270cm x h: 45cm). This report describes the outline of shallow land simulation apparatuses : function of apparatuses and specification of devices, analysis of obstructions, safety rules, analysis of accidents and operation manual. (author)

  6. Synthesis gas method and apparatus

    Science.gov (United States)

    Kelly, Sean M.; Kromer, Brian R.; Litwin, Michael M.; Rosen, Lee J.; Christie, Gervase Maxwell; Wilson, Jamie R.; Kosowski, Lawrence W.; Robinson, Charles

    2013-01-08

    A method and apparatus for producing a synthesis gas product having one or more oxygen transport membrane elements thermally coupled to one or more catalytic reactors such that heat generated from the oxygen transport membrane element supplies endothermic heating requirements for steam methane reforming reactions occurring within the catalytic reactor through radiation and convention heat transfer. A hydrogen containing stream containing no more than 20 percent methane is combusted within the oxygen transport membrane element to produce the heat and a heated combustion product stream. The heated combustion product stream is combined with a reactant stream to form a combined stream that is subjected to the reforming within the catalytic reactor. The apparatus may include modules in which tubular membrane elements surround a central reactor tube.

  7. Micromachined patch-clamp apparatus

    Science.gov (United States)

    Okandan, Murat

    2012-12-04

    A micromachined patch-clamp apparatus is disclosed for holding one or more cells and providing electrical, chemical, or mechanical stimulation to the cells during analysis with the patch-clamp technique for studying ion channels in cell membranes. The apparatus formed on a silicon substrate utilizes a lower chamber formed from silicon nitride using surface micromachining and an upper chamber formed from a molded polymer material. An opening in a common wall between the chambers is used to trap and hold a cell for analysis using the patch-clamp technique with sensing electrodes on each side of the cell. Some embodiments of the present invention utilize one or more electrostatic actuators formed on the substrate to provide mechanical stimulation to the cell being analyzed, or to provide information about mechanical movement of the cell in response to electrical or chemical stimulation.

  8. Thermoplastic welding apparatus and method

    Energy Technology Data Exchange (ETDEWEB)

    Matsen, Marc R.; Negley, Mark A.; Geren, William Preston; Miller, Robert James

    2017-03-07

    A thermoplastic welding apparatus includes a thermoplastic welding tool, at least one tooling surface in the thermoplastic welding tool, a magnetic induction coil in the thermoplastic welding tool and generally encircling the at least one tooling surface and at least one smart susceptor in the thermoplastic welding tool at the at least one tooling surface. The magnetic induction coil is adapted to generate a magnetic flux field oriented generally parallel to a plane of the at least one smart susceptor.

  9. Coated substrate apparatus and method

    Energy Technology Data Exchange (ETDEWEB)

    Bao, Zhenan; Diao, Ying; Mannsfeld, Stefan Christian Bernhardt; Tee, Chee-Keong; Becerril-Garcia, Hector A.; Zhou, Yan

    2018-01-09

    A coated substrate is formed with aligned objects such as small molecules, macromolecules and nanoscale particulates, such as inorganic, organic or inorganic/organic hybrid materials. In accordance with one or more embodiments, an apparatus or method involves an applicator having at least one surface patterned with protruded or indented features, and a coated substrate including a solution-based layer of objects having features and morphology attributes arranged as a function of the protruded or indented features.

  10. Cooling apparatus and couplings therefor

    Science.gov (United States)

    Lomax, Curtis; Webbon, Bruce

    1993-11-01

    A cooling apparatus includes a container filled with a quantity of coolant fluid initially cooled to a solid phase, a cooling loop disposed between a heat load and the container. A pump for circulating a quantity of the same type of coolant fluid in a liquid phase through the cooling loop, a pair of couplings for communicating the liquid phase coolant fluid into the container in a direct interface with the solid phase coolant fluid.

  11. Lateral flow strip assay

    Science.gov (United States)

    Miles, Robin R [Danville, CA; Benett, William J [Livermore, CA; Coleman, Matthew A [Oakland, CA; Pearson, Francesca S [Livermore, CA; Nasarabadi, Shanavaz L [Livermore, CA

    2011-03-08

    A lateral flow strip assay apparatus comprising a housing; a lateral flow strip in the housing, the lateral flow strip having a receiving portion; a sample collection unit; and a reagent reservoir. Saliva and/or buccal cells are collected from an individual using the sample collection unit. The sample collection unit is immersed in the reagent reservoir. The tip of the lateral flow strip is immersed in the reservoir and the reagent/sample mixture wicks up into the lateral flow strip to perform the assay.

  12. A tissue snap-freezing apparatus without sacrificial cryogens

    Science.gov (United States)

    Vanapalli, Srinivas; Jagga, Sahil; Holland, Harry; ter Brake, Marcel

    2017-12-01

    Molecular technologies in cancer diagnosis require a fresh and frozen tissue, which is obtained by means of snap-freezing. Currently, coolants such as solid carbon dioxide and liquid nitrogen are used to preserve good morphology of the tissue. Using these coolants, snap freezing of tissues for diagnostic and research purposes is often time consuming, laborious, even hazardous and not user friendly. For that reason snap-freezing is not routinely applied at the location of biopsy acquisition. Furthermore, the influence of optimal cooling rate and cold sink temperature on the viability of the cells is not well known. In this paper, a snap-freezing apparatus powered by a small cryocooler is presented that will allow bio-medical research of tissue freezing methods and is safe to use in a hospital. To benchmark this apparatus, cooldown of a standard aluminum cryo-vial in liquid nitrogen is measured and the cooling rate is about -25 K/s between 295 K and 120 K. Sufficient cooling rate is obtained by a forced convective helium gas flow through a gap formed between the cryo-vial and a cold surface and is therefore chosen as the preferred cooling method. A conceptual design of the snap-apparatus with forced flow is discussed in this paper.

  13. Method and apparatus for thermal energy storage. [Patent application

    Science.gov (United States)

    Gruen, D.M.

    1975-08-19

    A method and apparatus for storing energy by converting thermal energy to potential chemically bound energy in which a first metal hydride is heated to dissociation temperature, liberating hydrogen gas which is compressed and reacted with a second metal to form a second metal hydride while releasing thermal energy. Cooling the first metal while warming the second metal hydride to dissociation temperature will reverse the flow of hydrogen gas back to the first metal, releasing additional thermal energy. The method and apparatus are particularly useful for the storage and conversion of thermal energy from solar heat sources and for the utilization of this energy for space heating purposes, such as for homes or offices.

  14. Apparatuses And Systems For Embedded Thermoelectric Generators

    KAUST Repository

    Hussain, Muhammad M.

    2013-08-08

    An apparatus and a system for embedded thermoelectric generators are disclosed. In one embodiment, the apparatus is embedded in an interface where the ambient temperatures on two sides of the interface are different. In one embodiment, the apparatus is fabricated with the interface in integrity as a unitary piece. In one embodiment, the apparatus includes a first thermoelectric material embedded through the interface. The apparatus further includes a second thermoelectric material embedded through the interface. The first thermoelectric material is electrically coupled to the second thermoelectric material. In one embodiment, the apparatus further includes an output structure coupled to the first thermoelectric material and the second thermoelectric material and configured to output a voltage.

  15. A low cost apparatus for measuring the xylem hydraulic conductance in plants

    Directory of Open Access Journals (Sweden)

    Luciano Pereira

    2012-01-01

    Full Text Available Plant yield and resistance to drought are directly related to the efficiency of the xylem hydraulic conductance and the ability of this system to avoid interrupting the flow of water. In this paper we described in detail the assembling of an apparatus proposed by TYREE et al. (2002, and its calibration, as well as low cost adaptations that make the equipment accessible for everyone working in this research area. The apparatus allows measuring the conductance in parts of roots or shoots (root ramifications or branches, or in the whole system, in the case of small plants or seedlings. The apparatus can also be used to measure the reduction of conductance by embolism of the xylem vessels. Data on the hydraulic conductance of eucalyptus seedlings obtained here and other reports in the literature confirm the applicability of the apparatus in physiological studies on the relationship between productivity and water stress.

  16. Methods and apparatus for carbon dioxide removal from a fluid stream

    Science.gov (United States)

    Wei, Wei; Ruud, James Anthony; Ku, Anthony Yu-Chung; Ramaswamy, Vidya; Liu, Ke

    2010-01-19

    An apparatus for producing hydrogen gas wherein the apparatus includes a reactor. In one embodiment, the reactor includes at least two conversion-removal portions. Each conversion-removal portion comprises a catalyst section configured to convert CO in the stream to CO.sub.2 and a membrane section located downstream of and in flow communication with the catalyst section. The membrane section is configured to selectively remove the CO.sub.2 from the stream and to be in flow communication with a sweep gas.

  17. Multispectral imaging method and apparatus

    Science.gov (United States)

    Sandison, David R.; Platzbecker, Mark R.; Vargo, Timothy D.; Lockhart, Randal R.; Descour, Michael R.; Richards-Kortum, Rebecca

    1999-01-01

    A multispectral imaging method and apparatus adapted for use in determining material properties, especially properties characteristic of abnormal non-dermal cells. A target is illuminated with a narrow band light beam. The target expresses light in response to the excitation. The expressed light is collected and the target's response at specific response wavelengths to specific excitation wavelengths is measured. From the measured multispectral response the target's properties can be determined. A sealed, remote probe and robust components can be used for cervical imaging

  18. Nitrogen fixation method and apparatus

    Science.gov (United States)

    Chen, H.L.

    1983-08-16

    A method and apparatus for achieving nitrogen fixation includes a volumetric electric discharge chamber. The volumetric discharge chamber provides an even distribution of an electron beam, and enables the chamber to be maintained at a controlled energy to pressure (E/p) ratio. An E/p ratio of from 5 to 15 kV/atm of O[sub 2]/cm promotes the formation of vibrationally excited N[sub 2]. Atomic oxygen interacts with vibrationally excited N[sub 2] at a much quicker rate than unexcited N[sub 2], greatly improving the rate at which NO is formed. 1 fig.

  19. X-ray diffraction apparatus

    International Nuclear Information System (INIS)

    Padini, F.R.

    1978-01-01

    The invention provides an x-ray diffraction apparatus permitting the rotation of the divergence sit in conjunction with the rotation of the x-ray irradiated specimen, whereby the dimensions of the x-ray irradiated portion of the specimen remain substantially constant during the rotation of the specimen. In a preferred embodiment, the divergence slit is connected to a structural element linked with a second structural element connected to the specimen such that the divergence slit rotates at a lower angular speed than the specimen

  20. Coeliac cavity ultrasonic diagnosis apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Ando, O.; Suwaki, T.

    1983-07-05

    A coeliac cavity ultrasonic diagnosis apparatus is disclosed which includes an ultrasonic transducer or scanner portion adapted to be inserted into a coeliac cavity to effect a sector scan of an ultrasonic beam to produce an ultrasonic image of internal tissues and in which the ultrasonic oscillator on the one hand and an ultrasonic reflecting mirror and rotary disc on the other hand are relatively rotated so as to effect the sector scan of the ultrasonic beam and the rotary angle of the rotary disc is detected so as to obtain a deflecting angle of the ultrasonic beam and a display on a cathode ray tube of a precise ultrasonic picture image.

  1. Cluster Implantation and Deposition Apparatus

    DEFF Research Database (Denmark)

    Hanif, Muhammad; Popok, Vladimir

    2015-01-01

    In the current report, a design and capabilities of a cluster implantation and deposition apparatus (CIDA) involving two different cluster sources are described. The clusters produced from gas precursors (Ar, N etc.) by PuCluS-2 can be used to study cluster ion implantation in order to develop...... contributions to the theory of cluster stopping in matter as well as for practical applications requiring ultra-shallow implantation and modification of surfaces on the nanoscale. Metal clusters from the magnetron cluster source are of interest for the production of optical sensors to detect specific biological...

  2. Apparatus for incinerating hazardous waste

    Science.gov (United States)

    Chang, R.C.W.

    1994-12-20

    An apparatus is described for incinerating wastes, including an incinerator having a combustion chamber, a fluid-tight shell enclosing the combustion chamber, an afterburner, an off-gas particulate removal system and an emergency off-gas cooling system. The region between the inner surface of the shell and the outer surface of the combustion chamber forms a cavity. Air is supplied to the cavity and heated as it passes over the outer surface of the combustion chamber. Heated air is drawn from the cavity and mixed with fuel for input into the combustion chamber. The pressure in the cavity is maintained at least approximately 2.5 cm WC higher than the pressure in the combustion chamber. Gases cannot leak from the combustion chamber since the pressure outside the chamber (inside the cavity) is higher than the pressure inside the chamber. The apparatus can be used to treat any combustible wastes, including biological wastes, toxic materials, low level radioactive wastes, and mixed hazardous and low level transuranic wastes. 1 figure.

  3. Fuel cell catholyte regenerating apparatus

    International Nuclear Information System (INIS)

    Struthers, R. C.

    1985-01-01

    A catholyte regenerating apparatus for a fuel cell having a cathode section containing a catholyte solution and wherein fuel cell reaction reduces the catholyte to gas and water. The apparatus includes means to conduct partically reduced water diluted catholyte from the fuel cell and means to conduct the gas from the fuel cell to a mixing means. An absorption tower containing a volume of gas absorbing liquid solvent receives the mixed together gas and diluted catholyte from the mixing means within the absorption column, the gas is absorbed by the solvent and the gas ladened solvent and diluted catholyte are commingled. A liquid transfer means conducts gas ladened commingled. A liquid transfer means conducts gas ladened commingled solvent and electrolyte from the absorption column to an air supply means wherein air is added and commingled therewith and a stoichiometric volume of oxygen from the air is absorbed thereby. A second liquid transfer means conducts the gas ladened commingled solvent and diluted catholyte into a catalyst column wherein the oxygen and gas react to reconstitute the catholyte from which the gas was generated wna wherein the reconstituted diluted catholyte is separated from the solvent. Recirculating means conducts the solvent from the catalyst column back into the absorption column and liquid conducting means conducts the reconstituted catholyte to a holding tank preparatory for catholyte to a holding tank preparatory for recirculation through the cathode section of the fuel cell

  4. Apparatus for use in radioimmunoassays

    International Nuclear Information System (INIS)

    Chen, C-H.; Tsay, H-M.; Heyer, R.E.

    1979-01-01

    Apparatus for solid-phase antibody separation techniques used in radioimmunoassays is described in this invention. It consists of a rectangular prism tray with multiple wells protruding into its interior from one side. Near the base of the tray is an orifice used for creating evacuated condition within the structure. At the base of each well there is an orifice of such size and shape as to retain an aqueous liquid under given pressure conditions but permit the evacuation of this liquid at reduced pressure. The outlet of these orifices is in the shape of an inverted conical frustrum. Each of the wells contains an antibody coated disc of porous cellulose paper surrounded by a plastic support. The porous nature of the cellulose paper ensures contact between the antibody coating and the antigen. The use of antibody coated porous cellulose paper in combination with the vacuum operated apparatus simplifies the manipulative steps whilst still maintaining the sensitivity of the radioimmunoassay. It also obviates the need for aspiration and thus lessens the risk of contamination from one sample to another. (UK)

  5. BETA (Bitter Electromagnet Testing Apparatus)

    Science.gov (United States)

    Bates, Evan M.; Birmingham, William J.; Rivera, William F.; Romero-Talamas, Carlos A.

    2017-10-01

    The Bitter Electromagnet Testing Apparatus (BETA) is a 1-Tesla (T) prototype of the 10-T Adjustable Long Pulse High-Field Apparatus (ALPHA). These water-cooled resistive magnets use high DC currents to produce strong uniform magnetic fields. Presented here is the successful completion of the BETA project and experimental results validating analytical magnet designing methods developed at the Dusty Plasma Laboratory (DPL). BETA's final design specifications will be highlighted which include electromagnetic, thermal and stress analyses. The magnet core design will be explained which include: Bitter Arcs, helix starters, and clamping annuli. The final version of the magnet's vessel and cooling system are also presented, as well as the electrical system of BETA, which is composed of a unique solid-state breaker circuit. Experimental results presented will show the operation of BETA at 1 T. The results are compared to both analytical design methods and finite element analysis calculations. We also explore the steady state maximums and theoretical limits of BETA's design. The completion of BETA validates the design and manufacturing techniques that will be used in the succeeding magnet, ALPHA.

  6. Nuclear reactor core servicing apparatus

    International Nuclear Information System (INIS)

    Andrea, C.

    1977-01-01

    Disclosed is an improved core servicing apparatus for a nuclear reactor of the type having a reactor vessel, a vessel head having a head penetration therethrough, a removable plug adapted to fit in the head penetration, and a core of the type having an array of elongated assemblies. The improved core servicing apparatus comprises a plurality of support columns suspended from the removable plug and extending downward toward the nuclear core, rigid support means carried by each of the support columns, and a plurality of servicing means for each of the support columns for servicing a plurality of assemblies. Each of the plurality of servicing means for each of the support columns is fixedly supported in a fixed array from the rigid support means. Means are provided for rotating the rigid support means and servicing means between condensed and expanded positions. When in the condensed position, the rigid support means and servicing means lie completely within the coextensive boundaries of the plug, and when in the expanded position, some of the rigid support means and servicing means lie without the coextensive boundaries of the plug

  7. Master-slave micromanipulator apparatus

    Science.gov (United States)

    Morimoto, Alan K.; Kozlowski, David M.; Charles, Steven T.; Spalding, James A.

    1999-01-01

    An apparatus based on precision X-Y stages that are stacked. Attached to arms projecting from each X-Y stage are a set of two axis gimbals. Attached to the gimbals is a rod, which provides motion along the axis of the rod and rotation around its axis. A dual-planar apparatus that provides six degrees of freedom of motion precise to within microns of motion. Precision linear stages along with precision linear motors, encoders, and controls provide a robotics system. The motors can be positioned in a remote location by incorporating a set of bellows on the motors and can be connected through a computer controller that will allow one to be a master and the other one to be a slave. Position information from the master can be used to control the slave. Forces of interaction of the slave with its environment can be reflected back to the motor control of the master to provide a sense of force sensed by the slave. Forces import onto the master by the operator can be fed back into the control of the slave to reduce the forces required to move it.

  8. Apparatus Named after Our Academic Ancestors, III

    Science.gov (United States)

    Greenslade, Thomas B., Jr.

    2014-01-01

    My academic ancestors in physics have called on me once more to tell you about the apparatus that they devised, and that many of you have used in your demonstrations and labs. This article is about apparatus named after François Arago, Heinrich Helmholtz, Leon Foucault, and James Watt.

  9. Radiation therapy apparatus having retractable beam stopper

    International Nuclear Information System (INIS)

    Coad, G.L.

    1983-01-01

    This invention relates to a radiation therapy apparatus which utilized a linear translation mechanism for positioning a beam stopper. An apparatus is described wherein the beam stopper is pivotally attached to the therapy machine with an associated drive motor in such a way that the beam stopper retracts linearly

  10. Method and apparatus for producing microspherical particles

    International Nuclear Information System (INIS)

    Egli, W.; Bailey, W.H.; Leary, D.F.; Lansley, R.J.

    1979-01-01

    This invention relates generally to a method and apparatus for producing microspherical particles and more particularly to a method and apparatus which are particularly useful in connection with the sol-gel process for the production of nuclear fuel kernels. (U.K.)

  11. The Acoustical Apparatus of Rudolph Koenig.

    Science.gov (United States)

    Greenslade, Thomas B., Jr.

    1992-01-01

    Discusses the history of Rudolph Koenig's contribution to the development of acoustical apparatus. Contributions include the clock fork to determine absolute acoustic frequencies, a forerunner of the oscilloscope called the manometric flame, and an acoustic interference apparatus used in the Fourier synthesis of musical sounds. (MDH)

  12. An Apparatus to Measure Thermal Conductivity of Spray-On Foam Insulation

    Science.gov (United States)

    Barrios, M.; Sciver, S. W. Van

    2010-04-01

    A guarded-hot-plate apparatus has been developed to measure the thermal conductivity of various spray-on foam insulations (SOFI) at temperatures ranging from 20-300 K. The apparatus is designed to accept 222 mm (8.75″) diameter, 25.4 mm (1″) thick insulation samples, although different thicknesses can be accommodated. The apparatus is cooled with a two stage, pulse tube cryocooler, and the temperature is controlled with thin film etched foil heaters. This system allows thermal conductivity measurements to be made at low delta-T (ΔTheat flow axially through the sample. A gas handling system allows testing with different residual gases and pressures. To check for potential systematic errors, a finite element analysis was performed to examine temperature distribution and heat flow in the experimental chamber.

  13. Apparatus for localizing disturbances in pressurized water reactors (PWR)

    International Nuclear Information System (INIS)

    Sykora, D.

    1989-01-01

    The invention according to CS-PS 177386, entitled ''Apparatus for increasing the efficiency and passivity of the functioning of a bubbling-vacuum system for localizing disturbances in nuclear power plants with a pressurized water reactor'', concerns an important area of nuclear power engineering that is being developed in the RGW member countries. The invention solves the problems of increasing the reliability and intensification during the operation of the above very important system for guaranteeing the safety of the standard nuclear power plants of Soviet design. The essence of the invention consists in the installation of a simple passively operating supplementary apparatus. Consequently, the following can be observed in the system: first an improvement and simultaneous increase in the reliability of its function during the critical transition period, which follows the filling of the second space with air from the first space; secondly, elimination of the hitherto unavoidable initiating role of the active sprinkler-condensation device present; thirdly, a more effective performance and subjection of the elements to disintegration of the water flowing from the bubbling condenser into the first space; and fourthly, an enhanced utilization of the heat-conducting ability of the water reservoir of the bubbling condenser. Representatives of the supplementary apparatus are autonomous and local secondary systems of the sprinkler-sprayer without an insert, which spray the water under the effect of gravity. 1 fig

  14. Development of an antihydrogen trapping apparatus

    CERN Document Server

    Jenkins, Matthew James

    This thesis details the development and commissioning of the ALPHA antihydrogen trapping apparatus. It discusses the history of antimatter physics that led to and enabled the design of the apparatus. It discusses the importance of antihydrogen trapping in testing one of the basic assumptions of the Standard Model of particle physics (that of CPT invariance). It goes on to discuss the design and construction of the apparatus. Finally, it presents results that demonstrate antihydrogen formation in the new magnetic field configurations that together constitute a magnetic minimum trap for neutral antihydrogen. This is an important preliminary result for any antihydrogen trapping apparatus, and confirms that the ALPHA apparatus does present a potential route towards laser spectroscopy of antihydrogen.

  15. Automatic gamma spectrometry analytical apparatus

    International Nuclear Information System (INIS)

    Lamargot, J.-P.; Wanin, Maurice.

    1980-01-01

    This invention falls within the area of quantitative or semi-quantitative analysis by gamma spectrometry and particularly refers to a device for bringing the samples into the counting position. The purpose of this invention is precisely to provide an automatic apparatus specifically adapted to the analysis of hard gamma radiations. To this effect, the invention relates to a gamma spectrometry analytical device comprising a lead containment, a detector of which the sensitive part is located inside the containment and additionally comprising a transfer system for bringing the analyzed samples in succession to a counting position inside the containment above the detector. A feed compartment enables the samples to be brought in turn one by one on to the transfer system through a duct connecting the compartment to the transfer system. Sequential systems for the coordinated forward feed of the samples in the compartment and the transfer system complete this device [fr

  16. Assembly apparatus for nuclear reactors

    International Nuclear Information System (INIS)

    Boczek, W.

    1976-01-01

    A hoisting apparatus for assembling and operating a nuclear reactor comprises two rope drums, two gear mechanisms, and two hoisting mechanisms each with one rope for a predetermined load, a change-speed gear mechanism or shiftable gear mechanism for the selectable adjustment of various hoisting speeds for the two hoisting mechanisms, a drive connection which is provided for at least one gear mechanism and permits different distances between the said gear mechanism and the change-speed gear mechanism, a common motor for the two hoisting mechanisms, a rigid connection for the two lifting mechanisms which permits different distances between the lifting mechanisms, and a rope compensating device selectively adjustable so as to be operative or inoperative

  17. Hermetic Seal Leak Detection Apparatus

    Science.gov (United States)

    Kelley, Anthony R. (Inventor)

    2013-01-01

    The present invention is a hermetic seal leak detection apparatus, which can be used to test for hermetic seal leaks in instruments and containers. A vacuum tight chamber is created around the unit being tested to minimize gas space outside of the hermetic seal. A vacuum inducing device is then used to increase the gas chamber volume inside the device, so that a slight vacuum is pulled on the unit being tested. The pressure in the unit being tested will stabilize. If the stabilized pressure reads close to a known good seal calibration, there is not a leak in the seal. If the stabilized pressure reads closer to a known bad seal calibration value, there is a leak in the seal. The speed of the plunger can be varied and by evaluating the resulting pressure change rates and final values, the leak rate/size can be accurately calculated.

  18. Apparatus for sampling hazardous media

    International Nuclear Information System (INIS)

    Gardner, J.F.; Showalter, T.W.

    1984-01-01

    An apparatus for sampling a hazardous medium, such as radioactive or chemical waste, selectively collects a predetermined quantity of the medium in a recess of an end-over-end rotatable valving member. This collected quantity is deposited in a receiving receptacle located in a cavity while the receiving receptacle is in a sealed relationship with a recess to prevent dusting of the sampled media outside the receiving receptacle. The receiving receptacle is removably fitted within a vehicle body which is, in turn, slidably movable upon a track within a transport tube. The receiving receptacle is transported in the vehicle body from its sample receiving position within a container for the hazardous medium to a sample retrieval position outside the medium container. The receiving receptacle may then be removed from the vehicle body, capped and taken to a laboratory for chemical analysis. (author)

  19. Dental X-ray apparatus

    International Nuclear Information System (INIS)

    Weiss, M.E.

    1980-01-01

    Intra-oral dental X-ray apparatus for panoramic dental radiography is described in detail. It comprises an electron gun having an elongated tubular target carrier extending into the patient's mouth. The carrier supports an inclined target for direction of an X-ray pattern towards a film positioned externally of the patient's mouth. Image definition is improved by a focusing anode which focuses the electron beam into a sharp spot (0.05 to 0.10 mm diameter) on the target. The potential on the focusing anode is adjustable to vary the size of the spot. An X-ray transmitting ceramic (oxides of Be, Al and Si) window is positioned adjacent to the front face of the target. The electron beam can be magnetically deflected to change the X-ray beam direction. (author)

  20. Development of capsule assembling apparatus

    International Nuclear Information System (INIS)

    Tayama, Yoshinobu; Kanazawa, Yoshiharu; Sozawa, Shizuo; Kawamata, Kazuo; Shizuoka, Yoshihiro; Onizawa, Satoshi; Nakagawa, Tetsuya

    2012-01-01

    The service of JMTR hot laboratory, associated with the Japan Materials Testing Reactor, was started on 1971 to examine specimens irradiated mainly in the JMTR. A wide variety of post irradiation examinations for research and development of nuclear fuels and materials are available in the JMTR hot laboratory. This laboratory has an advantage that its hot cell is connected with JMTR by a canal directly, and it is easy to transport irradiated capsule and specimens. New power ramping test for the high burn-up fuels by using the JMTR has been planed. The power ramping test using a boiling water capsule facility needs a re-capsuling of fuel rods for re-irradiation, and a modification of the facility up to about 100 GWD/t were necessary. This report introduces the new handling techniques and capsule assembling apparatus for the boiling water capsule facility. (author)

  1. Power conversion apparatus and method

    Science.gov (United States)

    Su, Gui-Jia [Knoxville, TN

    2012-02-07

    A power conversion apparatus includes an interfacing circuit that enables a current source inverter to operate from a voltage energy storage device (voltage source), such as a battery, ultracapacitor or fuel cell. The interfacing circuit, also referred to as a voltage-to-current converter, transforms the voltage source into a current source that feeds a DC current to a current source inverter. The voltage-to-current converter also provides means for controlling and maintaining a constant DC bus current that supplies the current source inverter. The voltage-to-current converter also enables the current source inverter to charge the voltage energy storage device, such as during dynamic braking of a hybrid electric vehicle, without the need of reversing the direction of the DC bus current.

  2. Isotope separation method and apparatus

    International Nuclear Information System (INIS)

    Lyon, R.K.; Eisner, P.N.; Thomas, W.R.L.

    1980-01-01

    A method and apparatus are specified for separating a mixture of isotopes present in a compound, preferably a gaseous compound, into two or more parts in each of which the abundances of the isotopes differ from the natural abundances of the isotopes in the compound. The invention particularly relates to carrying out a laser induced, isotopically selective conversion of gaseous molecules in such a manner as to achieve more than one stage of isotope separation along the length of the laser beam. As an example, the invention is applied to the separation of the isotopes of uranium in UF 6 , in which either the U-235 or U-238 isotope is selectively excited by means of irradiation from an infrared laser, and the selectively excited isotope converted into a product that can be recovered from UF 6 by one of a variety of methods that are described. (U.K.)

  3. Apparatuses to support photovoltaic modules

    Energy Technology Data Exchange (ETDEWEB)

    Ciasulli, John; Jones, Jason

    2017-08-22

    Methods and apparatuses to support photovoltaic ("PV") modules are described. A saddle bracket has a mounting surface to support one or more PV modules over a tube, a gusset coupled to the mounting surface, and a mounting feature coupled to the gusset to couple to the tube. A grounding washer has a first portion to couple to a support; and a second portion coupled to the first portion to provide a ground path to a PV module. A PV system has a saddle bracket; a PV module over the saddle bracket; and a grounding washer coupled to the saddle bracket and the PV module. Saddle brackets can be coupled to a torque tube at predetermined locations. PV modules can be coupled to the saddle brackets.

  4. Multileaf collimator and related apparatus

    International Nuclear Information System (INIS)

    Brown, K.J.

    1989-01-01

    In radiotherapy apparatus using a multileaf collimator, the adjustment positions of the individual leaves can be determined optically by means of a video camera which observes the leaves via a radiation transparent mirror in the beam path. In order to overcome problems of low contrast and varying object brightness, the improvement comprises adding retroreflectors to the collimator leaves whose positions are known relative to the inner edge of the respective leaf. The retroreflectors can extend along the length of the leaf or they can be small. For setting up, corresponding manually adjustable optical diaphragm leaves can be used to project an optical simulation of the treatment area onto the patient, retroreflectors being similarly located relative to the shadow-casting edge of the leaves. (author)

  5. Modeling of column apparatus processes

    CERN Document Server

    Boyadjiev, Christo; Boyadjiev, Boyan; Popova-Krumova, Petya

    2016-01-01

    This book presents a new approach for the modeling of chemical and interphase mass transfer processes in industrial column apparatuses, using convection-diffusion and average-concentration models. The convection-diffusion type models are used for a qualitative analysis of the processes and to assess the main, small and slight physical effects, and then reject the slight effects. As a result, the process mechanism can be identified. It also introduces average concentration models for quantitative analysis, which use the average values of the velocity and concentration over the cross-sectional area of the column. The new models are used to analyze different processes (simple and complex chemical reactions, absorption, adsorption and catalytic reactions), and make it possible to model the processes of gas purification with sulfur dioxide, which form the basis of several patents.

  6. Dental X-ray apparatus

    International Nuclear Information System (INIS)

    Weiss, M.E.

    1980-01-01

    Intra-oral X-ray apparatus which reduces the number of exposures necessary to obtain panoramic dental radiographs is described in detail. It comprises an electron gun, a tubular target carrier projecting from the gun along the beam axis and carrying at its distal end a target surrounded by a shield of X-ray opaque material. This shield extends forward and laterally of the target and has surfaces which define a wedge or cone-shaped radiation pattern delimited vertically by the root tips of the patient's teeth. A film holder is located externally of the patient's mouth. A disposable member can fit on the target carrier to depress the patient's tongue out of the radiation pattern and to further shield the roof of the mouth. The electron beam can be magnetically deflected to change the X-ray beam direction. (author)

  7. An automatic refolding apparatus for preparative-scale protein production.

    Directory of Open Access Journals (Sweden)

    Yanye Feng

    Full Text Available Protein refolding is an important process to recover active recombinant proteins from inclusion bodies. Refolding by simple dilution, dialysis and on-column refolding methods are the most common techniques reported in the literature. However, the refolding process is time-consuming and laborious due to the variability of the behavior of each protein and requires a great deal of trial-and-error to achieve success. Hence, there is a need for automation to make the whole process as convenient as possible. In this study, we invented an automatic apparatus that integrated three refolding techniques: varying dilution, dialysis and on-column refolding. We demonstrated the effectiveness of this technology by varying the flow rates of the dilution buffer into the denatured protein and testing different refolding methods. We carried out different refolding methods on this apparatus: a combination of dilution and dialysis for human stromal cell-derived factor 1 (SDF-1/CXCL12 and thioredoxin fused-human artemin protein (Trx-ARTN; dilution refolding for thioredoxin fused-human insulin-like growth factor I protein (Trx-IGF1 and enhanced fluorescent protein (EGFP; and on-column refolding for bovine serum albumin (BSA. The protein refolding processes of these five proteins were preliminarily optimized using the slowly descending denaturants (or additives method. Using this strategy of decreasing denaturants concentration, the efficiency of protein refolding was found to produce higher quantities of native protein. The standard refolding apparatus configuration can support different operations for different applications; it is not limited to simple dilution, dialysis and on-column refolding techniques. Refolding by slowly decreasing denaturants concentration, followed by concentration or purification on-column, may be a useful strategy for rapid and efficient recovery of active proteins from inclusion bodies. An automatic refolding apparatus employing this

  8. 21 CFR 886.4100 - Radiofrequency electrosurgical cautery apparatus.

    Science.gov (United States)

    2010-04-01

    ... bleeding by a high frequency electric current. (b) Classification. Class II. ... electrosurgical cautery apparatus. (a) Identification. A radiofrequency electrosurgical cautery apparatus is an AC...

  9. Fire control apparatus for a laser weapon

    Science.gov (United States)

    Worsham, R. H.

    1985-10-01

    This patent application discloses a laser weapon fire control computer apparatus for responding in real time to the escort/threat scenario that confronts the weapon. The fire control computer apparatus compares the threat data with stored predicted scenarios to develop a firing strategy menu which takes into account the fact that the laser energy is instantaneously propagated to the target but requires a substantial amount of time to inflict damage. The fire control computer apparatus utilizes the weapon's status, dwell time, slow time and fuel limits to yield a weapon pointing sequence and weapon on-off times.

  10. Apparatus for concentrating by dual temperature exchange

    International Nuclear Information System (INIS)

    Spevack, J.S.

    1975-01-01

    Improvements in an apparatus for isotope concentration by dual temperature exchange between feed and auxiliary fluids in a multistage system are described. The first fluid is a vaporizable liquid and the auxiliary fluid a gas, the apparatus having means for cascading the auxiliary fluid and the feed fluid in vapor and preferably also in liquid form. The apparatus also contains new combinations of means for improving the heating and/or cooling and/or humidifying and/or dehumidifying operations of the system. The reactants in the example given are hydrogen sulfide gas and liquid water

  11. SCANNING AND TRACKING MONITORING APPARATUS AND METHOD

    DEFF Research Database (Denmark)

    2017-01-01

    Disclosed is a scanning monitoring apparatus for medical imaging, the scanning monitoring apparatus comprising a controller unit and a display, wherein the controller unit during a scanning session is configured to obtain tracking data (102) of a subject in a medical scanner, obtain scanner data...... indicative of operating parameters of the medical scanner (104); determine an output of a verification function based on the tracking data and the scanner data (106); and control the scanning monitoring apparatus according to the output of the verification function (108). A notification signal may...

  12. Altitude Rating of Electric Apparatus

    Science.gov (United States)

    1943-01-01

    Si1- WS»’ +ea’ °c CD B^j.’ 1« a function of tha weight flow of air through tho machine and tha watts losa token away trj this air. Thus...0.133 qfor e (?) whom q^or vratts losa dissipated by forced convection weight flow of cooling air through machine, pounds per minute » • pi P

  13. Apparatus for Testing Flat Specimens of Thermal Insulation

    Science.gov (United States)

    Fesmire, James E.; Augustynowicz, Stanislaw D.

    2005-01-01

    An apparatus has been developed to implement an improved method of testing flat-plate specimens of thermal-insulation materials for cryogenic application. The method includes testing under realistic use conditions that could include vacuum and mechanical loading at a pressure up to 70 psi (=0.48 MPa). The apparatus can accommodate a rigid or flexible specimen having thickness up to 1.25 in. (=3.2 cm) and diameters between 6 and 10 in. (about 15.2 and 25.4 cm, respectively). Typical test conditions include boundary temperatures between 77 K and 373 K and vacuum/interstitial gas filling at a pressure between 10(exp -6) torr (=1.3 x 10(exp -4) Pa) and 760 torr (atmospheric pressure =0.1 MPa). The interstitial gas could be N2, He, CO2, or any other suitable gas to which the insulation is expected to be exposed in use. Relative to prior apparatuses and testing methods, this apparatus and the testing method that it implements offer advantages of relative simplicity and ease of use. The basic principle of operation of the apparatus is that of boil-off calorimetry, using liquid nitrogen or any other suitable liquid that boils at a desired temperature below ambient temperature. Comparative rates of flow of heat through the thicknesses of the specimens (heat-leak rates) and apparent-thermal-conductivity values are obtained from tests of specimens. Absolute values of heat-leak rates and apparent thermal conductivities are computed from a combination of (1) the aforementioned comparative values and (2) calibration factors obtained by testing reference specimens of materials that have known thermal-insulation properties. The apparatus includes a full complement of temperature sensors, a vacuum pump and chamber, a monitoring and control system, and tools and fixtures that enable rapid and reliable installation and removal of specimens. A specimen is installed at the bottom of the vacuum chamber, and a cold-mass assembly that includes a tank is lowered into position above and

  14. Apparatus for and method of monitoring for breached fuel elements

    Science.gov (United States)

    Gross, Kenny C.; Strain, Robert V.

    1983-01-01

    This invention teaches improved apparatus for the method of detecting a breach in cladded fuel used in a nuclear reactor. The detector apparatus uses a separate bypass loop for conveying part of the reactor coolant away from the core, and at least three separate delayed-neutron detectors mounted proximate this detector loop. The detectors are spaced apart so that the coolant flow time from the core to each detector is different, and these differences are known. The delayed-neutron activity at the detectors is a function of the dealy time after the reaction in the fuel until the coolant carrying the delayed-neutron emitter passes the respective detector. This time delay is broken down into separate components including an isotopic holdup time required for the emitter to move through the fuel from the reaction to the coolant at the breach, and two transit times required for the emitter now in the coolant to flow from the breach to the detector loop and then via the loop to the detector. At least two of these time components are determined during calibrated operation of the reactor. Thereafter during normal reactor operation, repeated comparisons are made by the method of regression approximation of the third time component for the best-fit line correlating measured delayed-neutron activity against activity that is approximated according to specific equations. The equations use these time-delay components and known parameter values of the fuel and of the part and emitting daughter isotopes.

  15. Bi-planal angiographic apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Angiography apparatus has an L-arm rotatable about a vertical axis and a U-arm mounted on the upstanding section of the L-arm for rotation about a horizontal axis. An x-ray source is at one end of the U-arm and image receptors including an image intensifier and a first film changer are at the other end to enable making posterior-anterior and anterior-posterior x-ray views at various angles relative to a patient who is located on the isocenter which is the intersection of the horizontal, vertical and x-ray beam axis. A second film changer for making lateral generally isocentric views is mounted within the U-arm on a stand that is movable along the horizontal U-arm axis to allow obtaining various distances between the image plane of the film and another x-ray source. The lateral changer is on a mechanism for shifting it vertically and longitudinally a limited amount and for rotating it with a motor so this changer will stay level until the U-arm has been tilted through a pre-determined angle. After this angle is reached motorized rotation is discontinued and the lateral changer is allowed to rotate with the U-arm. (Auth.)

  16. Isotope separation apparatus and method

    International Nuclear Information System (INIS)

    Cotter, T.P.

    1982-01-01

    The invention relates to a method and apparatus for laser isotope separation by photodeflection. A molecular beam comprising at least two isotopes to be separated intersects, preferable substantially perpendicular to one broad side of the molecular beam, with a laser beam traveling in a first direction. The laser beam is reflected back through the molecular beam, preferably in a second direction essentially opposite to the first direction. The laser beam comprises pi-pulses of a selected wavelength which excite unexcited molecules, or cause stimulated emission of excited molecules of one of the isotopes. Excitation caused by first direction pi-pulses moves molecules of the isotope excited thereby in the first direction. Stimulated emission of excited molecules of the isotope is brought about by returning pi-pulses traveling in the second direction. Stimulated emission moves emitting molecules in a direction opposite to the photon emitted. Because emitted photons travel in the second direction, emitting molecules move in the first direction. Substantial molecular movement is accomplished by a large number of pi-pulse-molecule interactions. A beam corer collects the molecules in the resulting enriched divergent portions of the beam

  17. Hanging drop crystal growth apparatus

    Science.gov (United States)

    Naumann, Robert J. (Inventor); Witherow, William K. (Inventor); Carter, Daniel C. (Inventor); Bugg, Charles E. (Inventor); Suddath, Fred L. (Inventor)

    1990-01-01

    This invention relates generally to control systems for controlling crystal growth, and more particularly to such a system which uses a beam of light refracted by the fluid in which crystals are growing to detect concentration of solutes in the liquid. In a hanging drop apparatus, a laser beam is directed onto drop which refracts the laser light into primary and secondary bows, respectively, which in turn fall upon linear diode detector arrays. As concentration of solutes in drop increases due to solvent removal, these bows move farther apart on the arrays, with the relative separation being detected by arrays and used by a computer to adjust solvent vapor transport from the drop. A forward scattering detector is used to detect crystal nucleation in drop, and a humidity detector is used, in one embodiment, to detect relative humidity in the enclosure wherein drop is suspended. The novelty of this invention lies in utilizing angular variance of light refracted from drop to infer, by a computer algorithm, concentration of solutes therein. Additional novelty is believed to lie in using a forward scattering detector to detect nucleating crystallites in drop.

  18. Dental X-ray apparatus

    International Nuclear Information System (INIS)

    Weiss, M.E.

    1980-01-01

    Intra-oral dental X-ray apparatus for panoramic radiography is described in detail. It comprises a tubular target carrier supporting at its distal end a target with an inclined forward face. Image definition is improved by positioning in the path of the X-rays a window of X-ray transmitting ceramic material, e.g. 90% oxide of Be, or Al, 7% Si0 2 . The target carrier forms a probe which can be positioned in the patient's mouth. X-rays are directed forwardly and laterally of the target to an X-ray film positioned externally. The probe is provided with a detachable sleeve having V-form arms of X-ray opaque material which serve to depress the tongue out of the radiation path and also shield the roof of the mouth and other regions of the head from the X-ray pattern. A cylindrical lead shield defines the X-ray beam angle. (author)

  19. Apparatus for experimental investigation of aerodynamic radiation with absorption by ablation products

    Science.gov (United States)

    Wells, W. L.; Snow, W. L.

    1977-01-01

    A description is given and calibration procedures are presented for an apparatus that is used to simulate aerodynamic radiant heating during planetary entry. The primary function of the apparatus is to simulate the spectral distribution of shock layer radiation and to determine absorption effects of simulated ablation products which are injected into the stagnation region flow field. An electric arc heater is used to heat gas mixtures that represent the planetary atmospheres of interest. Spectral measurements are made with a vacuum ultraviolet scanning monochromator.

  20. Gas-phase hydrosilylation of cyclohexene in an experimental radiation-chemical accelerator apparatus

    International Nuclear Information System (INIS)

    Pecherkin, A.S.; Sidorov, V.I.; Chernyshev, E.A.

    1992-01-01

    A process for the synthesis of methylcyclohexyldichlorosilane (a basic monomer for the production of organosilicon photoresists) has been investigated and perfected on an experimental apparatus with an ELV-2 electron accelerator; this synthesis involves gas-phase radiation-induced hydrosilylation of cyclohexene by methyldichlorosilane. Basic characteristics of the yield of the desired product under static conditions were determined. With the help of experiments on the synthesis of methylcyclohexyldichlorosilane in a flow- through mode, the technical features of the process of radiation-chemical hydrosilylation of cyclohexene on an accelerator apparatus were determined and studied, the optimal conditions for the synthesis were determined, and an experimental batch of the desired product was produced

  1. Apparatus and method for noninvasive particle detection using doppler spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Sinha, Dipen N.

    2016-05-31

    An apparatus and method for noninvasively detecting the presence of solid particulate matter suspended in a fluid flowing through a pipe or an oil and gas wellbore are described. Fluid flowing through a conduit containing the particulate solids is exposed to a fixed frequency (>1 MHz) of ultrasonic vibrations from a transducer attached to the outside of the pipe. The returning Doppler frequency shifted signal derived from the scattering of sound from the moving solid particles is detected by an adjacent transducer. The transmitted signal and the Doppler signal are combined to provide sensitive particulate detection. The magnitude of the signal and the Doppler frequency shift are used to determine the particle size distribution and the velocity of the particles. Measurement of the phase shift between the applied frequency and the detected Doppler shifted may be used to determine the direction of motion of the particles.

  2. Multi-stage fuel cell system method and apparatus

    Science.gov (United States)

    George, Thomas J.; Smith, William C.

    2000-01-01

    A high efficiency, multi-stage fuel cell system method and apparatus is provided. The fuel cell system is comprised of multiple fuel cell stages, whereby the temperatures of the fuel and oxidant gas streams and the percentage of fuel consumed in each stage are controlled to optimize fuel cell system efficiency. The stages are connected in a serial, flow-through arrangement such that the oxidant gas and fuel gas flowing through an upstream stage is conducted directly into the next adjacent downstream stage. The fuel cell stages are further arranged such that unspent fuel and oxidant laden gases too hot to continue within an upstream stage because of material constraints are conducted into a subsequent downstream stage which comprises a similar cell configuration, however, which is constructed from materials having a higher heat tolerance and designed to meet higher thermal demands. In addition, fuel is underutilized in each stage, resulting in a higher overall fuel cell system efficiency.

  3. Neutron logging reliability techniques and apparatus

    International Nuclear Information System (INIS)

    Johnstone, C.W.

    1975-01-01

    Apparatus and methods for verifying the validity of data derived at least in part by neutron logging of earth formations, and, where indicated, for affording neutron diffusion-corrected values of such data, are disclosed. (WHK)

  4. Method and apparatus for measuring electromagnetic radiation

    Science.gov (United States)

    Been, J. F. (Inventor)

    1973-01-01

    An apparatus and method are described in which the capacitance of a semiconductor junction subjected to an electromagnetic radiation field is utilized to indicate the intensity or strength of the radiation.

  5. 42 CFR 84.74 - Apparatus containers; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Apparatus containers; minimum requirements. 84.74...-Contained Breathing Apparatus § 84.74 Apparatus containers; minimum requirements. (a) Apparatus may be equipped with a substantial, durable container bearing markings which show the applicant's name, the type...

  6. Universal penetration test apparatus with fluid penetration sensor

    Science.gov (United States)

    Johnson, P.W.; Stampfer, J.F.; Bradley, O.D.

    1999-02-02

    A universal penetration test apparatus is described for measuring resistance of a material to a challenge fluid. The apparatus includes a pad saturated with the challenge fluid. The apparatus includes a compression assembly for compressing the material between the pad and a compression member. The apparatus also includes a sensor mechanism for automatically detecting when the challenge fluid penetrates the material. 23 figs.

  7. Flow Study of a Novel Ionizer Configuration with Testing Apparatus

    National Research Council Canada - National Science Library

    Armstrong, John D

    2008-01-01

    .... This thesis reports on the ionization of Argon, an alternative propellant to Xenon, which has been achieved at relatively low voltages with locally designed and manufactured Micro-Structured Electrode (MSE) Arrays...

  8. Investigation of the influence of heated catalyst feeding system on the intensity of temperature-dependent chemical reaction in the fluidized bed apparatus

    Science.gov (United States)

    Soloveva, O. V.; Solovyev, S. A.

    2016-11-01

    A mathematical model was developed and a numerical study of operation parameters of the fluidized bed apparatus for temperature-dependent processes was performed. Fields of catalyst concentration and temperature fields were obtained. The circulation flow analysis was carried out. The effect of the influence of heated catalyst feeder on the efficiency of apparatus heating was analyzed. The change of the circulating gas flows and catalyst structures due to changes in the heated catalyst feeder was shown. The influence of the catalyst fractional composition on the efficiency of apparatus heating was studied.

  9. Proton imaging apparatus for proton therapy application

    International Nuclear Information System (INIS)

    Sipala, V.; Lo Presti, D.; Brianzi, M.; Civinini, C.; Bruzzi, M.; Scaringella, M.; Talamonti, C.; Bucciolini, M.; Cirrone, G.A.P.; Cuttone, G.; Randazzo, N.; Stancampiano, C.; Tesi, M.

    2011-01-01

    Radiotherapy with protons, due to the physical properties of these particles, offers several advantages for cancer therapy as compared to the traditional radiotherapy and photons. In the clinical use of proton beams, a p CT (Proton Computer Tomography) apparatus can contribute to improve the accuracy of the patient positioning and dose distribution calculation. In this paper a p CT apparatus built by the Prima (Proton Imaging) Italian Collaboration will be presented and the preliminary results will be discussed.

  10. Report upon inquiry into radiation apparatus

    International Nuclear Information System (INIS)

    1984-10-01

    In this report the committee has provided its assessment of the need and justification for the law to provide for the control of the provision of radiation apparatus, the planning needs for the provision of diagnostic and therapeutic facilities, the location of such facilities, the appropriateness or otherwise of existing legislation, the necessity for any further legislative needs and the criteria governing the provision of such radiation apparatus

  11. Simulation of gas compressible flow by free surface water flow

    International Nuclear Information System (INIS)

    Altafini, C.R.; Silva Ferreira, R.T. da

    1981-01-01

    The analogy between the water flow with a free surface and the compressible fluid flow, commonly called hydraulic analogy, is analyzed and its limitations are identified. The water table is the equipment used for this simulation, which allows the quatitative analysis of subsonic and supersonic flow with a low cost apparatus. The hydraulic analogy is applied to subsonic flow around circular cylinders and supersonic flow around cones. The results are compared with available theoretical and experimental data and a good agreement is achieved. (Author) [pt

  12. Quantum behaviour of measuring apparatus

    International Nuclear Information System (INIS)

    Amri, T.

    2011-05-01

    This thesis explores the quantum behavior of measurement apparatus with illustrations in quantum optics. This is the first study of quantum properties of measurements performed by any kind of devices. We show that the quantum properties of a measurement, such as its projective or non-classical character, are revealed only by the quantum states of an unusual approach of quantum physics: the retrodictive approach. This approach involves retro-predictions about state preparations leading to a given measurement result, contrary to the predictive approach with which we usually make predictions about the results of an experiment. By clarifying the mathematical foundations of the retrodictive approach, we propose a general procedure for reconstructing the quantum states of this approach: the retrodicted states. We have realized these reconstructions for single-photon detectors, widely used in quantum cryptography for instance. This is the first tomography of quantum states totally based on the retrodictive approach and preparation choices, contrary to usual reconstructions based on measurement results. These tomographies enabled us to study experimentally the noise influence on the quantum properties of measurements performed by these detectors, in particular their transition from a strongly quantum behavior into a more classical behavior. Finally, we propose a detector of Schroedinger's Cat states of light, which are superpositions of incompatible quasi-classical states of light. In a modern version of a thought experiment proposed by Eugene Wigner in 1961, such a device could allow the Wigner's Friend to detect a Schroedinger's Cat, contrary to human eyes for which we specify some quantum properties. We generalize the use of such a non-classical detector to an estimation protocol, totally based on the retrodictive approach and preparation choices. Such a procedure could enable optimal estimations, by reaching the quantum Cramer-Rao bound, which is a very topical issue

  13. Structural power flow measurement

    Energy Technology Data Exchange (ETDEWEB)

    Falter, K.J.; Keltie, R.F.

    1988-12-01

    Previous investigations of structural power flow through beam-like structures resulted in some unexplained anomalies in the calculated data. In order to develop structural power flow measurement as a viable technique for machine tool design, the causes of these anomalies needed to be found. Once found, techniques for eliminating the errors could be developed. Error sources were found in the experimental apparatus itself as well as in the instrumentation. Although flexural waves are the carriers of power in the experimental apparatus, at some frequencies longitudinal waves were excited which were picked up by the accelerometers and altered power measurements. Errors were found in the phase and gain response of the sensors and amplifiers used for measurement. A transfer function correction technique was employed to compensate for these instrumentation errors.

  14. Corrosion detector apparatus for universal assessment of pollution in data centers

    Science.gov (United States)

    Hamann, Hendrik F.; Klein, Levente I.

    2015-08-18

    A compact corrosion measurement apparatus and system includes an air fan, a corrosion sensor, a temperature sensor, a humidity sensor, a heater element, and an air flow sensor all under control to monitor and maintain constant air parameters in an environment and minimize environmental fluctuations around the corrosion sensor to overcome the variation commonly encountered in corrosion rate measurement. The corrosion measurement apparatus includes a structure providing an enclosure within which are located the sensors. Constant air flow and temperature is maintained within the enclosure where the corrosion sensor is located by integrating a variable speed air fan and a heater with the corresponding feedback loop control. Temperature and air flow control loops ensure that corrosivity is measured under similar conditions in different facilities offering a general reference point that allow a one to one comparison between facilities with similar or different pollution levels.

  15. Acoustic concentration of particles in fluid flow

    Science.gov (United States)

    Ward, Michael D.; Kaduchak, Gregory

    2010-11-23

    An apparatus for acoustic concentration of particles in a fluid flow includes a substantially acoustically transparent membrane and a vibration generator that define a fluid flow path therebetween. The fluid flow path is in fluid communication with a fluid source and a fluid outlet and the vibration generator is disposed adjacent the fluid flow path and is capable of producing an acoustic field in the fluid flow path. The acoustic field produces at least one pressure minima in the fluid flow path at a predetermined location within the fluid flow path and forces predetermined particles in the fluid flow path to the at least one pressure minima.

  16. Design of neutral particle incident heating apparatus for large scale helical apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Kaneko, Osamu; Oka, Yoshihide; Osakabe, Masaki; Takeiri, Yasuhiko; Tsumori, Katsuyoshi; Akiyama, Ryuichi; Asano, Eiji; Kawamoto, Toshikazu; Kuroda, Tsutomu [National Inst. for Fusion Science, Nagoya (Japan)

    1997-02-01

    In the Institute of Nuclear Fusion Science, construction of the large scale helical apparatus has been progressed favorably, and constructions of the heating apparatus as well as of electron resonance apparatus were begun in their orders under predetermined manner since 1994 fiscal year. And, on 1995 fiscal year, construction of neutral particle incident heating apparatus, leading heat apparatus, was begun under 3 years planning. The plasma heating study system adopted the study results developed in this institute through the large scale hydrogen negative ion source and also adopted thereafter development on nuclear fusion study by modifying the original specification set at the beginning of the research plan before 7 years. As a result, system design was changed from initial 125 KeV to 180 KeV in the beam energy and to execute 15 MW incidence using two sets beam lines, to begin its manufacturing. Here is described on its new design with reason of its modifications. (G.K.)

  17. Forced air heat sink apparatus

    Science.gov (United States)

    Rippel, Wally E. (Inventor)

    1989-01-01

    A high efficiency forced air heat sink assembly employs a split feed transverse flow configuration to minimize the length of the air flow path through at least two separated fin structures. Different embodiments use different fin structure material configurations including honeycomb, corrugated and serpentine. Each such embodiment uses a thermally conductive plate having opposed exterior surfaces; one for receiving a component to be cooled and one for receiving the fin structures. The serpentine structured fin embodiment employs a plurality of fin supports extending from the plate and forming a plurality of channels for receiving the fin structures. A high thermal conductivity bondant, such as metal-filled epoxy, may be used to bond the fin structures to either the plate or the fin supports. Dip brazing and soldering may also be employed depending upon the materials selected.

  18. Information flow in quantum teleportation

    Indian Academy of Sciences (India)

    Abstract. The flow of information is discussed in the context of quantum teleportation. Situations are described which use a sequence of systems of particles in which, though there is no claim of faster-than-light signaling, it is plausible to suggest that information about measurement procedures in one wing of the apparatus ...

  19. A Study on Test Technology to Diagnose the Power Apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Kim, K. H.; Kang, Y. S.; Jeon, Y. K.; Lee, W. Y.; Kang, D. S.; Kyu, H. S.; Sun, J. H.; Jo, K. H. [Korea Electrotechnology Research Institute (Korea, Republic of); Jung, J. S.; Mun, Y. T.; Lee, K. H.; Jung, E. H.; Kim, J. H. [Korea Water Resources Corporation (Korea, Republic of)

    1997-02-01

    In this study, we have educated KOWACO(Korea Water Resources Corporation) specialists about the insulation diagnostic technology and trained them the insulation diagnostic test and estimation method of power apparatus. The main results of this study are as follows; A. Education of basic high-voltage engineering. B. Research of insulation characteristic and deterioration mechanism in power apparatus C. Discussion on high-voltage test standard specifications. D. Study on insulation deterioration diagnostics in power apparatus. E. Field testing of insulation diagnosis in power apparatus. F. Engineering of insulation diagnostic testing apparatus to diagnose power apparatus. KOWACO specialists are able to diagnose insulation diagnostic test of power apparatus through this study. As they have instruments to diagnose power apparatus, they can do the test and estimation of the power apparatus insulation diagnosis. (author). refs., figs., tabs.

  20. Otolithic apparatus of tetrapods after space flight

    Science.gov (United States)

    Lychakov, Dmitri

    In vertebrates the otolithic membrane is formed of three components: the gelatinous layer, the subcupular meshwork and the otolithic apparatus (Fermin et al., 1998; Lim, 1974; Lindeman, 1969; Lychakov, 1988, 2002). The otolithic apparatus consists of a set of small crystalline otoconia (Tetrapoda), or a single large crystalline otolith (Teleostei). Despite similar functions, the otoconia (Tetrapoda) and otolith otolithic apparatus differ significantly in their embryogenesis, postembryonic growth, chemical composition, etc. It may be suggested that the gravitational challenges may have different effects on otoconia or otoliths. Unfortunately, we have only a few quantitative data on structural adaptation of tetrapod otolithic apparatus to microgravity (Lychakov, 2002; Lychakov, Lavrova,1985; Wiederhold et al., 1997). The BION-M1 provides an opportunity for a quantitative morphological analysis of otolithic apparatus of adult mice exposed to 30 days in a biosatellite on orbit. We expect to analyse otoconia of utriculus and sacculus. Our principal aims are to investigate the morphological characteristics of otoconia. We expect to get novel insights in microgravity induced otoconia adaptation of tetrapods. This work was partly supported by Russian grant RFFI 14-04-00601.

  1. Apparatus and method for phosphate-accelerated bioremediation

    Science.gov (United States)

    Looney, Brian B.; Pfiffner, Susan M.; Phelps, Tommy J.; Lombard, Kenneth H.; Hazen, Terry C.; Borthen, James W.

    1998-01-01

    An apparatus and method for supplying a vapor-phase nutrient to contaminated soil for in situ bioremediation. The apparatus includes a housing adapted for containing a quantity of the liquid nutrient, a conduit in communication with the interior of the housing, means for causing a gas to flow through the conduit, and means for contacting the gas with the liquid so that a portion thereof evaporates and mixes with the gas. The mixture of gas and nutrient vapor is delivered to the contaminated site via a system of injection and extraction wells configured to the site and provides for the use of a passive delivery system. The mixture has a partial pressure of vaporized nutrient that is no greater than the vapor pressure of the liquid. If desired, the nutrient and/or the gas may be heated to increase the vapor pressure and the nutrient concentration of the mixture. Preferably, the nutrient is a volatile, substantially nontoxic and nonflammable organic phosphate that is a liquid at environmental temperatures, such as triethyl phosphate or tributyl phosphate.

  2. Method and apparatus for detecting micro-organisms

    International Nuclear Information System (INIS)

    Mirsky, J.

    1976-01-01

    A method and apparatus is described for determining the presence and quantity of microorganisms, such as bacteria, fungi and yeast, in a given sample. The apparatus includes two sealed containers, a portion of which may be penetrated by a sharp instrument, as for example, glass vials with flexible septum tops. One container includes a radioactive nutrient medium which is capable of supporting the life process of the microorganism whose presence is being tested. The second container includes a liquid scintillation solution which absorbs the product of metabolism of the organisms. The sample is introduced into the first sealed container, for example, by means of a standard syringe. Any microorganisms present will consume the radioactive nutrient and as a result produce radioactive waste. Means are then applied to penetrate the containers and allow the flow of the radioactive metabolic product from the first container to the second container while preventing any contamination from the ambient. The liquid scintillation solution will emit light in proportion to the amount of the product of metabolism collected from the first container. This light may be detected by standard liquid scintillation counters, thus providing a qualitative and quantitative measure of the microorganism in the tested sample

  3. Biaxial casting apparatus for isolating radioactive waste

    International Nuclear Information System (INIS)

    Manchale, F. Jr.; Manchak, F. III.

    1992-01-01

    This patent describes apparatus for isolating hazardous radioactive waste for disposal. It comprises: a bifurcated centrifugal casting mold having at least two separable mold parts, the mold being supported for rotation about a first axis; means for supporting a completed monolith in the apparatus with the mold parts removed therefrom; powered drive means for rotating the mold and the monolith about the first axis; mold removal means aligned along a second axis substantially perpendicular to the first axis for removing the separate parts of the bifurcated casting mold from a monolith while leaving the monolith supported in the apparatus for rotation about the first axis; means for injecting a charge of radiation shielding material into a pre-formed shell placed in the mold; and means for heating the interior of the shell during rotation of the mold about the first axis

  4. Programmers for diagnostic x-ray apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Novel apparatus is described for providing a pre-programmed selection of various parameters in X-ray radiography. The equipment consists of push-buttons which prompt the radiographer to make decisions such as thickness of patient, part of the anatomy to be X-rayed etc. From these data the apparatus selects the appropriate parameters such as H.T. voltage, current, product of current and irradiation time etc. The values of these parameters are displayed to the radiographer and facilities are provided to override the programmed parameters at the radiographer's discretion. (U.K.)

  5. Apparatuses and methods for generating electric fields

    Science.gov (United States)

    Scott, Jill R; McJunkin, Timothy R; Tremblay, Paul L

    2013-08-06

    Apparatuses and methods relating to generating an electric field are disclosed. An electric field generator may include a semiconductive material configured in a physical shape substantially different from a shape of an electric field to be generated thereby. The electric field is generated when a voltage drop exists across the semiconductive material. A method for generating an electric field may include applying a voltage to a shaped semiconductive material to generate a complex, substantially nonlinear electric field. The shape of the complex, substantially nonlinear electric field may be configured for directing charged particles to a desired location. Other apparatuses and methods are disclosed.

  6. APPARATUS FOR HANDLING MIXTURES OF SOLID MATERIALS

    Science.gov (United States)

    Hubbell, J.P.

    1959-08-25

    An apparatus is described for handling either a mixture of finely subdivided materials or a single material requiring a compacting action thereon preparatory to a chemical reducing process carried out in a crucible container. The apparatus is designed to deposit a mixture of dust-forming solid materials in a container while confining the materials against escape into the surrounding atmosphere. A movable filling tube, having a compacting member, is connected to the container and to a covered hopper receiving the mixture of materials. The filling tube is capable of reciprocating in the container and their relative positions are dependent upon the pressure established upon the material by the compacting member.

  7. Apparatus for handling control rod drives

    International Nuclear Information System (INIS)

    Akimoto, A.; Watanabe, M.; Yoshida, T.; Sugaya, Z.; Saito, T.; Ishii, Y.

    1979-01-01

    An apparatus for handling control rod drives (CRD's) attached by detachable fixing means to housings mounted in a reactor pressure vessel and each coupled to one of control rods inserted in the reactor pressure vessel is described. The apparatus for handling the CRD's comprise cylindrical housing means, uncoupling means mounted in the housing means for uncoupling each of the control rods from the respective CRD, means mounted on the housing means for effecting attaching and detaching of the fixing means, means for supporting the housing means, and means for moving the support means longitudinally of the CRD

  8. Apparatus for isotopic alteration of mercury vapor

    Science.gov (United States)

    Grossman, Mark W.; George, William A.; Marcucci, Rudolph V.

    1988-01-01

    An apparatus for enriching the isotopic Hg content of mercury is provided. The apparatus includes a reactor, a low pressure electric discharge lamp containing a fill including mercury and an inert gas. A filter is arranged concentrically around the lamp. In a preferred embodiment, constant mercury pressure is maintained in the filter by means of a water-cooled tube that depends from it, the tube having a drop of mercury disposed in it. The reactor is arranged around the filter, whereby radiation from said lamp passes through the filter and into said reactor. The lamp, the filter and the reactor are formed of a material which is transparent to ultraviolet light.

  9. Method and apparatus for testing microfilaments

    Science.gov (United States)

    Schleitweiler, Patrick M.; Merten, Jr., Charles W.

    1995-08-01

    A method and apparatus are disclosed for testing tensile strength of microfilaments. Fibers as small as 0.001 inch in diameter and 0.04 inches in length have been tested, although the method and apparatus of the invention are capable of testing fibers of smaller diameter and length. The invention utilizes a method wherein one or both ends of a microfilament is gripped using resin which is softened sufficiently to accept an end of the microfilament and then allowed to harden. The invention also employs the use of a translation stage capable of controlled three-dimensional movement suited to facilitating gripping of the microfilament.

  10. Method and apparatus for testing microfilaments

    Energy Technology Data Exchange (ETDEWEB)

    Schleitweiler, P.M.; Merten, C.W. Jr.

    1995-08-01

    A method and apparatus are disclosed for testing tensile strength of microfilaments. Fibers as small as 0.001 inch in diameter and 0.04 inches in length have been tested, although the method and apparatus of the invention are capable of testing fibers of smaller diameter and length. The invention utilizes a method wherein one or both ends of a microfilament is gripped using resin which is softened sufficiently to accept an end of the microfilament and then allowed to harden. The invention also employs the use of a translation stage capable of controlled three-dimensional movement suited to facilitating gripping of the microfilament. 2 figs.

  11. Methods and apparatus for controlling rotary machines

    Science.gov (United States)

    Bagepalli, Bharat Sampathkumaran [Niskayuna, NY; Jansen, Patrick Lee [Scotia, NY; Barnes, Gary R [Delanson, NY; Fric, Thomas Frank [Greer, SC; Lyons, James Patrick Francis [Niskayuna, NY; Pierce, Kirk Gee [Simpsonville, SC; Holley, William Edwin [Greer, SC; Barbu, Corneliu [Guilderland, NY

    2009-09-01

    A control system for a rotary machine is provided. The rotary machine has at least one rotating member and at least one substantially stationary member positioned such that a clearance gap is defined between a portion of the rotating member and a portion of the substantially stationary member. The control system includes at least one clearance gap dimension measurement apparatus and at least one clearance gap adjustment assembly. The adjustment assembly is coupled in electronic data communication with the measurement apparatus. The control system is configured to process a clearance gap dimension signal and modulate the clearance gap dimension.

  12. Apparatus for controlling molten core debris

    International Nuclear Information System (INIS)

    Golden, M.P.; Tilbrook, R.W.; Heylmun, N.F.

    1972-01-01

    Disclosed is an apparatus for containing, cooling, diluting, dispersing and maintaining subcritical the molten core debris assumed to melt through the bottom of a nuclear reactor pressure vessel in the unlikely event of a core meltdown. The apparatus is basically a sacrificial bed system which includes an inverted conical funnel, a core debris receptacle including a spherical dome, a spherically layered bed of primarily magnesia bricks, a cooling system of zig-zag piping in graphite blocks about and below the bed and a cylindrical liner surrounding the graphite blocks including a steel shell surrounded by firebrick. Tantalum absorber rods are used in the receptacle and bed. 9 claims, 22 figures

  13. Apparatus and process for controlling fluidized beds

    Science.gov (United States)

    Rehmat, Amirali G.; Patel, Jitendra G.

    1985-10-01

    An apparatus and process for control and maintenance of fluidized beds under non-steady state conditions. An ash removal conduit is provided for removing solid particulates from a fluidized bed separate from an ash discharge conduit in the lower portion of the grate supporting such a bed. The apparatus and process of this invention is particularly suitable for use in ash agglomerating fluidized beds and provides control of the fluidized bed before ash agglomeration is initiated and during upset conditions resulting in stable, sinter-free fluidized bed maintenance.

  14. Low-level radioactive waste disposal process and apparatus

    International Nuclear Information System (INIS)

    White, L.E.; Anderson, R.E.; Vander Wall, E.M.

    1980-01-01

    The primary object of this invention is to provide an improved process and apparatus for disposing of low-level liquid radioactive wastes wherein the volume of the wastes can be reduced by a factor of at least ten to thereby minimize costs of storage and ultimate disposal of the wastes. The wastes will be in a form more suitable for storage, transit and burial while still conforming to safety codes. Another object of this invention is to provide a process of disposing of low-level liquid radioactive wastes wherein the wastes are reduced in volume to a mass of free-flowing, solid particles by calcining and the particles are packaged in the presence of a solidifying agent or the particles are compressed, sintered or fused to cause the wastes to be converted to a monolithic product capable of being readily and more safely stored or moved to a burial site. (auth)

  15. Acoustic agglomeration methods and apparatus

    Science.gov (United States)

    Barmatz, M. B. (Inventor)

    1984-01-01

    Methods are described for using acoustic energy to agglomerate fine particles on the order of one micron diameter that are suspended in gas, to provide agglomerates large enough for efficient removal by other techniques. The gas with suspended particles, is passed through the length of a chamber while acoustic energy at a resonant chamber mode is applied to set up one or more acoustic standing wave patterns that vibrate the suspended particles to bring them together so they agglomerate. Several widely different frequencies can be applied to efficiently vibrate particles of widely differing sizes. The standing wave pattern can be applied along directions transversed to the flow of the gas. The particles can be made to move in circles by applying acoustic energy in perpendicular directions with the energy in both directions being of the same wavelength but 90 deg out of phase.

  16. Methods and apparatus for use with extreme ultraviolet light having contamination protection

    Science.gov (United States)

    Chilese, Francis C.; Torczynski, John R.; Garcia, Rudy; Klebanoff, Leonard E.; Delgado, Gildardo R.; Rader, Daniel J.; Geller, Anthony S.; Gallis, Michail A.

    2016-07-12

    An apparatus for use with extreme ultraviolet (EUV) light comprising A) a duct having a first end opening, a second end opening and an intermediate opening intermediate the first end opening the second end opening, B) an optical component disposed to receive EUV light from the second end opening or to send light through the second end opening, and C) a source of low pressure gas at a first pressure to flow through the duct, the gas having a high transmission of EUV light, fluidly coupled to the intermediate opening. In addition to or rather than gas flow the apparatus may have A) a low pressure gas with a heat control unit thermally coupled to at least one of the duct and the optical component and/or B) a voltage device to generate voltage between a first portion and a second portion of the duet with a grounded insulative portion therebetween.

  17. Self contained compressed air breathing apparatus to facilitate personnel decontamination

    International Nuclear Information System (INIS)

    McDonald, C.W.

    1963-11-01

    This report describes the modification of a Self Contained Compressed Air Breathing Apparatus to provide extended respiratory protection to grossly contaminated personnel during a decontamination period which may exceed the duration of the Breathing Apparatus air supply. (author)

  18. Process and apparatus for controlling control rods

    International Nuclear Information System (INIS)

    Gebelin, B.; Couture, R.

    1987-01-01

    This process and apparatus is characterized by 2 methods, for examination of cluster of nuclear control rods. Foucault current analyzer which examines fraction by fraction all the control rods. This examination is made by rotation of the cluster. Doubtful rods are then analysed by ultrasonic probe [fr

  19. Method and apparatus for assembling battery components

    Energy Technology Data Exchange (ETDEWEB)

    Sabatino, A.; Romanchuk, R. N.; Schaumburg, E. G.; Stanefski, E. F.

    1985-04-09

    A method and apparatus for assembling battery components including a battery case having a plurality of divider walls defining a plurality of side-by-side cell spaces opening through a top portion of the case. A plurality of intermediate cell elements are provided in the cell spaces intermediate the end cell spaces and end cell elements having terminal post portions are inserted in the end cell spaces. The apparatus effects an automatic pickup of the cell elements at one or more insert stations from delivery conveyors suitably positions the picked-up cell elements for proper polarity relationship in the inserted disposition within the battery case, and after moving the picked-up cell elements to overlying relationship with the battery case, inserts the cell elements automatically into the proper cell spaces. Control of delivery of the battery cases to the respective insert positions is effected and coordinated with the delivery of the necessary cell elements from apparatus for preforming the cell elements. Apparatus is provided for accurately spacing the end cell elements upon delivery thereof to the pickup position. The pickup structure includes finger devices arranged to engage plate connecting straps provided on the cell elements in effecting positive pickup, transfer and insertion thereof.

  20. Kinematic X-Ray Analysis Apparatus

    NARCIS (Netherlands)

    Koningsberger, D.C.; Brinkgreve, P.

    1983-01-01

    In an X-ray analysis apparatus, a moving mechanism is provided by a main guide member along which a main slide device can be displaced. Rotatably connected with the main slide device is a detector guide member along which a detection slide device is displaced. The main slide device, as well as the

  1. Cold neutron radiographic apparatus and method

    International Nuclear Information System (INIS)

    Larsen, J.E.

    1979-01-01

    An improved cold neutron radiographic apparatus and method are disclosed wherein neutron temperature is matched to the specific material to be examined. This can be done, in one embodiment, by placing a radioactive source of neutrons, such as californium-252, in a moderator such as solid methane and using a cryogenic refrigeration system to cool the moderator to any preselected cryogenic temperature

  2. 49 CFR 236.590 - Pneumatic apparatus.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Pneumatic apparatus. 236.590 Section 236.590 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RULES, STANDARDS, AND INSTRUCTIONS GOVERNING THE INSTALLATION, INSPECTION...

  3. Electroless plating apparatus for discrete microsized particles

    International Nuclear Information System (INIS)

    Mayer, A.

    1978-01-01

    Method and apparatus are disclosed for producing very uniform coatings of a desired material on discrete microsized particles by electroless techniques. Agglomeration or bridging of the particles during the deposition process is prevented by imparting a sufficiently random motion to the particles that they are not in contact with each other for a time sufficient for such to occur

  4. Apparatus for combining oxygen and hydrogen

    International Nuclear Information System (INIS)

    Betz, E.C.

    1977-01-01

    An apparatus is described for catalytically combining hydrogen and oxygen which includes two concentric catalyst chambers arranged so that the outer chamber surrounds the inner chamber and the gas stream passes radially through the outer catalyst chamber. 10 claims, 2 figures

  5. Great Experiments and Old Apparatus in Education.

    Science.gov (United States)

    Kovacs, Laszlo

    1996-01-01

    Describes an approach to teaching atomic, nuclear, and particle physics using the history of the most important discoveries in that field. Uses the manuscripts, first publications, measurements and data of initial discoveries, and the photos of apparatus and of famous physicists to arouse student interest. Presents examples from the life and work…

  6. Method and apparatus for synthesizing filamentary structures

    Science.gov (United States)

    Height, Murray J [Somerville, MA; Howard, Jack B [Winchester, MA; Vandersande, John B [Newbury, MA

    2008-02-26

    Method and apparatus for producing filamentary structures. The structures include single-walled nanotubes. The method includes combusting hydrocarbon fuel and oxygen to establish a non-sooting flame and providing an unsupported catalyst to synthesize the filamentary structure in a post-flame region of the flame. Residence time is selected to favor filamentary structure growth.

  7. Analysis apparatus and method of analysis

    International Nuclear Information System (INIS)

    1976-01-01

    A continuous streaming method developed for the excution of immunoassays is described in this patent. In addition, a suitable apparatus for the method was developed whereby magnetic particles are automatically employed for the consecutive analysis of a series of liquid samples via the RIA technique

  8. Method and apparatus for calibrating spectrophotometers

    NARCIS (Netherlands)

    Schreutelkamp, F.H.

    2003-01-01

    The present invention relates to a method of calibrating spectrophotometers by placing one or more filters in the light path of the spectrophotometer and measuring the amount of radiation by means of a detector. The present invention furthermore relates to an apparatus to be used with such a method.

  9. Improved cold neutron radiographic apparatus and method

    International Nuclear Information System (INIS)

    1981-01-01

    An improved cold neutron radiography technique is described in which the neutron temperature is matched to the specific material to be analyzed. In addition to a beam source and detector the apparatus incorporates a cryogenic refrigerator which enables the moderator material to be cooled to a predetermined adjustable temperature below the Bragg edge temperature of the sample. (U.K.)

  10. Process and apparatus for conversion of biomass

    NARCIS (Netherlands)

    Bakker, R.R.C.; Hazewinkel, J.H.O.; Groenestijn, van J.W.

    2006-01-01

    The invention is directed to a process for the conversion of cellulosic biomass, in particular lignocellulose-containing biomass into fermentable sugars. The invention is further directed to apparatus suitable for carrying out such processes. According to the invention biomass is converted into

  11. Process and apparatus for conversion of biomass

    NARCIS (Netherlands)

    Bakker, R.R.C.; Hazewinkel, J.H.O.; Groenestijn, van J.W.

    2006-01-01

    The invention is directed to a process for the conversion of biomass, in particular lignocellulose-containing biomass into a product that may be further processes in a fermentation step. The invention is further directed to apparatus suitable for carrying out such processes. According to the

  12. Apparatus for simulating a vascular interventional procedure

    NARCIS (Netherlands)

    Van den Dobbelsteen, J.J.; Dankelman, J.

    2008-01-01

    The invention relates to an apparatus (1) for simulating a vascular interventional procedure, comprising a wire-like element (7) representing an instrument to be inserted into a vascular tree, which wire-like element can be received in a holder (3), and wherein a sensor (12, 13) is provided for

  13. An extraordinary tabletop speed of light apparatus

    Science.gov (United States)

    Pegna, Guido

    2017-09-01

    A compact, low-cost, pre-aligned apparatus of the modulation type is described. The apparatus allows accurate determination of the speed of light in free propagation with an accuracy on the order of one part in 104. Due to the 433.92 MHz radio frequency (rf) modulation of its laser diode, determination of the speed of light is possible within a sub-meter measuring base and in small volumes (some cm3) of transparent solids or liquids. No oscilloscope is necessary, while the required function generators, power supplies, and optical components are incorporated into the design of the apparatus and its receiver can slide along the optical bench while maintaining alignment with the laser beam. Measurement of the velocity factor of coaxial cables is also easily performed. The apparatus detects the phase difference between the rf modulation of the laser diode by further modulating the rf signal with an audio frequency signal; the phase difference between these signals is then observed as the loudness of the audio signal. In this way, the positions at which the minima of the audio signal are found determine where the rf signals are completely out of phase. This phase detection method yields a much increased sensitivity with respect to the display of coincidence of two signals of questionable arrival time and somewhat distorted shape on an oscilloscope. The displaying technique is also particularly suitable for large audiences as well as in unattended exhibits in museums and science centers. In addition, the apparatus can be set up in less than one minute.

  14. 46 CFR 108.703 - Self-contained breathing apparatus.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Self-contained breathing apparatus. 108.703 Section 108... DESIGN AND EQUIPMENT Miscellaneous Equipment § 108.703 Self-contained breathing apparatus. (a) Each unit must be equipped with a self-contained breathing apparatus described in § 108.497(a) to use as...

  15. 46 CFR 169.736 - Self-contained breathing apparatus.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Self-contained breathing apparatus. 169.736 Section 169... VESSELS Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.736 Self-contained breathing apparatus. Each locker or space containing self-contained breathing apparatus must be marked “SELF-CONTAINED...

  16. 46 CFR 108.635 - Self-contained breathing apparatus.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Self-contained breathing apparatus. 108.635 Section 108... DESIGN AND EQUIPMENT Equipment Markings and Instructions § 108.635 Self-contained breathing apparatus. Each locker or space containing self-contained breathing apparatus must be marked: “SELF CONTAINED...

  17. Apparatus for measuring the strength of an electromagnetic field

    NARCIS (Netherlands)

    Leferink, Frank Bernardus Johannes; Buesink, Frederik Johannes Karel; Serra, Ramiro

    2011-01-01

    There is disclosed an apparatus for measuring the strength of an electromagnetic field. The apparatus comprises a plurality of antennas arranged such that the field is received from all directions, each antenna supplying an RF signal as output.The apparatus also compromises a plurality of

  18. 21 CFR 862.2485 - Electrophoresis apparatus for clinical use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electrophoresis apparatus for clinical use. 862... Instruments § 862.2485 Electrophoresis apparatus for clinical use. (a) Identification. An electrophoresis apparatus for clinical use is a device intended to separate molecules or particles, including plasma...

  19. Apparatus Named after Our Academic Ancestors--I

    Science.gov (United States)

    Greenslade, Thomas B., Jr.

    2010-01-01

    Let us now praise famous physicists, and the apparatus named after them, with apologies to the writer of Ecclesiastes. I once compiled a list of about 300 pieces of apparatus known to us as X's Apparatus. Some of the values of X are familiar, like Wheatstone and Kelvin and Faraday, but have you heard of Pickering or Rhumkorff or Barlow? In an…

  20. Operation and maintenance manuals for VEGA apparatus on radionuclide release from irradiated fuel

    International Nuclear Information System (INIS)

    Hayashida, Retsu; Hidaka, Akihide; Nakamura, Takehiko; Kudo, Tamotsu; Ohtomo, Takashi; Uetsuka, Hiroshi

    2001-03-01

    An experimental program, Verification Experiments of radionuclides Gas/Aerosol release (VEGA), was initiated at JAERI from September 1999 to improve source term predictabilities for hypothetical severe accidents. In the experiment, a short fuel segment taken from LWR fuels irradiated in Japanese power reactors is inductively heated to high temperatures (∼3273K) in a hot cell under high pressure conditions up to 1.0MPa. Particularly, a focus will be placed on the release and transport behaviors of low-volatile fission products (FP), actinides and short-life FP which have not been well investigated in previous studies. This experimental apparatus was completed in February 1999 and three experiments were performed by the end of 2000. Most of these experiments were successfully conducted, but some problems were also found. Especially, in the first VEGA-1 test with the purpose of shakedown and reference data acquisition, there were problems such as flow blockage at the outlet of furnace due to structure melting, malfunction of heaters and so on. Therefore, the design for these defective parts was changed for future experiments. Moreover, the apparatus is not so big but the entire processes are very complicated. Accordingly, the operators should well understand the details of the apparatus including the recent change of design. This report describes outlines of the VEGA apparatus and the procedures for operation and maintenance. (author)

  1. Operation and maintenance manuals for VEGA apparatus on radionuclide release from irradiated fuel

    Energy Technology Data Exchange (ETDEWEB)

    Hayashida, Retsu [Mitsubishi Kakoki Kaisha Ltd., Tokyo (Japan); Hidaka, Akihide; Nakamura, Takehiko; Kudo, Tamoatsu; Ohtomo, Takashi; Uetsuka, Hiroshi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2001-03-01

    An experimental program, Verification Experiments of radionuclides Gas/Aerosol release (VEGA), was initiated at JAERI from September 1999 to improve source term predictabilities for hypothetical severe accidents. In the experiment, a short fuel segment taken from LWR fuels irradiated in Japanese power reactors is inductively heated to high temperatures ({approx}3273K) in a hot cell under high pressure conditions up to 1.0MPa. Particularly, a focus will be placed on the release and transport behaviors of low-volatile fission products (FP), actinides and short-life FP which have not been well investigated in previous studies. This experimental apparatus was completed in February 1999 and three experiments were performed by the end of 2000. Most of these experiments were successfully conducted, but some problems were also found. Especially, in the first VEGA-1 test with the purpose of shakedown and reference data acquisition, there were problems such as flow blockage at the outlet of furnace due to structure melting, malfunction of heaters and so on. Therefore, the design for these defective parts was changed for future experiments. Moreover, the apparatus is not so big but the entire processes are very complicated. Accordingly, the operators should well understand the details of the apparatus including the recent change of design. This report describes outlines of the VEGA apparatus and the procedures for operation and maintenance. (author)

  2. New apparatus for training the avoidance reaction.

    Science.gov (United States)

    Tikal, K

    1988-01-01

    A new apparatus for active avoidance training in rats consists of a short, wide runway which can be tilted from a horizontal to vertical position. One half of the electrifiable grid floor is covered by a nonconducting sheet. For brightness (black-white) discrimination training a white walled goal box can be inserted into the runway and shifted from left to right during training. Avoidance training of 24 rats (female Wistar SPF) required 14.1 +/- 2.6 (mean +/- SEM) to-criterion trials (9/10) and was completed in less than 4 min. Brightness discrimination training required 21.3 +/- 2.1 to-criterion trials and the time of training did not exceed 12 min. The retention of the acquired responses was very good in both cases. The main advantage of the apparatus is very rapid acquisition of the one-way and discriminated avoidance without the necessity of manual manipulation of the animal.

  3. Ionomer-Membrane Water Processing Apparatus

    Science.gov (United States)

    MacCallum, Taber K. (Inventor); Kelsey, Laura (Inventor)

    2016-01-01

    This disclosure provides water processing apparatuses, systems, and methods for recovering water from wastewater such as urine. The water processing apparatuses, systems, and methods can utilize membrane technology for extracting purified water in a single step. A containment unit can include an ionomer membrane, such as Nafion(Registered Trademark), over a hydrophobic microporous membrane, such as polytetrafluoroethylene (PTFE). The containment unit can be filled with wastewater, and the hydrophobic microporous membrane can be impermeable to liquids and solids of the wastewater but permeable to gases and vapors of the wastewater, and the ionomer membrane can be permeable to water vapor but impermeable to one or more contaminants of the gases and vapors. The containment unit can be exposed to a dry purge gas to maintain a water vapor partial pressure differential to drive permeation of the water vapor, and the water vapor can be collected and processed into potable water.

  4. Apparatus for detecting leakage of liquid sodium

    Science.gov (United States)

    Himeno, Yoshiaki

    1978-01-01

    An apparatus for detecting the leakage of liquid sodium includes a cable-like sensor adapted to be secured to a wall of piping or other equipment having sodium on the opposite side of the wall, and the sensor includes a core wire electrically connected to the wall through a leak current detector and a power source. An accidental leakage of the liquid sodium causes the corrosion of a metallic layer and an insulative layer of the sensor by products resulted from a reaction of sodium with water or oxygen in the atmospheric air so as to decrease the resistance between the core wire and the wall. Thus, the leakage is detected as an increase in the leaking electrical current. The apparatus is especially adapted for use in detecting the leakage of liquid sodium from sodium-conveying pipes or equipment in a fast breeder reactor.

  5. Therapeutic radiation apparatus having an optical pointer

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification relates to a therapeutic irradiating apparatus including a radiation source arranged to provide a beam of penetrating radiation and an optical alignment indicator comprising at least two light sources each provided with means to provide a planar divergent beam of light located so that at least two light beams intersect along a line substantially coincident with the central axis of the path of the radiation beam. The claim relates to cylindrical lenses providing the means of providing the divergent beams, and to lasers as the light sources. Claims are also made for the apparatus providing means of supporting and aligning the patient, and for disposing the light sources so that the exit point of the radiation beam is illuminated. (U.K.)

  6. Apparatus, system, and method for traffic monitoring

    KAUST Repository

    Claudel, Christian G.

    2016-08-25

    An apparatus, system, and method for traffic monitory can have a Lagrangian inertial measurement unit. The Lagrangian inertial measurement unit can have a processor, an accelerometer, a gyroscope, and/or a wireless transmitter. The processor can have an integrated direction cosine matrix. The accelerometer can be configured to measure linear accelerations of a vehicle and/or can communicate measured linear acceleration to the processor. The gyroscope can be configured to measure rotational accelerations of the vehicle and/or can communicate measured rotational acceleration to the processor. The processor can be configured to calculate estimated vehicle speed and/or estimated vehicle attitude. The wireless transmitter can be configured to wirelessly transmit estimated vehicle speed and/or estimated vehicle attitude. The apparatus, system, and method can be integrated with a wireless sensor network.

  7. VCSEL fault location apparatus and method

    Science.gov (United States)

    Keeler, Gordon A [Albuquerque, NM; Serkland, Darwin K [Albuquerque, NM

    2007-05-15

    An apparatus for locating a fault within an optical fiber is disclosed. The apparatus, which can be formed as a part of a fiber-optic transmitter or as a stand-alone instrument, utilizes a vertical-cavity surface-emitting laser (VCSEL) to generate a test pulse of light which is coupled into an optical fiber under test. The VCSEL is subsequently reconfigured by changing a bias voltage thereto and is used as a resonant-cavity photodetector (RCPD) to detect a portion of the test light pulse which is reflected or scattered from any fault within the optical fiber. A time interval .DELTA.t between an instant in time when the test light pulse is generated and the time the reflected or scattered portion is detected can then be used to determine the location of the fault within the optical fiber.

  8. Apparatus and method for treating waste material

    International Nuclear Information System (INIS)

    Allison, W.

    1981-01-01

    Apparatus is described for the packaging of waste material in a vessel, comprising: a vessel entry station having inlet and outlet doors; a filling station downstream of the vessel entry station and having a filling position to which vessels are transferred from the entry station through the outlet door, the filling station having filling means for introducing radioactive waste into the vessel; a mixing station having a mixing position to which a vessel is transferred from the filling position; a capping station having a capping position to which a vessel is transferred from the mixing position; and means for effecting transfer of a vessel through the apparatus. Radiation shielding is provided. (U.K.)

  9. Data structures and apparatuses for representing knowledge

    Science.gov (United States)

    Hohimer, Ryan E; Thomson, Judi R; Harvey, William J; Paulson, Patrick R; Whiting, Mark A; Tratz, Stephen C; Chappell, Alan R; Butner, Robert S

    2014-02-18

    Data structures and apparatuses to represent knowledge are disclosed. The processes can comprise labeling elements in a knowledge signature according to concepts in an ontology and populating the elements with confidence values. The data structures can comprise knowledge signatures stored on computer-readable media. The knowledge signatures comprise a matrix structure having elements labeled according to concepts in an ontology, wherein the value of the element represents a confidence that the concept is present in an information space. The apparatus can comprise a knowledge representation unit having at least one ontology stored on a computer-readable medium, at least one data-receiving device, and a processor configured to generate knowledge signatures by comparing datasets obtained by the data-receiving devices to the ontologies.

  10. Spectroscopic Chemical Analysis Methods and Apparatus

    Science.gov (United States)

    Hug, William F. (Inventor); Reid, Ray D. (Inventor); Bhartia, Rohit (Inventor); Lane, Arthur L. (Inventor)

    2017-01-01

    Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted along with photoluminescence spectroscopy (i.e. fluorescence and/or phosphorescence spectroscopy) to provide high levels of sensitivity and specificity in the same instrument.

  11. Ultrasonic stir welding process and apparatus

    Science.gov (United States)

    Ding, R. Jeffrey (Inventor)

    2009-01-01

    An ultrasonic stir welding device provides a method and apparatus for elevating the temperature of a work piece utilizing at least one ultrasonic heater. Instead of relying on a rotating shoulder to provide heat to a workpiece an ultrasonic heater is utilized to provide ultrasonic energy to the workpiece. A rotating pin driven by a motor assembly performs the weld on the workpiece. A handheld version can be constructed as well as a fixedly mounted embodiment.

  12. Flash drive memory apparatus and method

    Science.gov (United States)

    Hinchey, Michael G. (Inventor)

    2010-01-01

    A memory apparatus includes a non-volatile computer memory, a USB mass storage controller connected to the non-volatile computer memory, the USB mass storage controller including a daisy chain component, a male USB interface connected to the USB mass storage controller, and at least one other interface for a memory device, other than a USB interface, the at least one other interface being connected to the USB mass storage controller.

  13. Apparatus for measurement of coefficient of friction

    Science.gov (United States)

    Slifka, A. J.; Siegwarth, J. D.; Sparks, L. L.; Chaudhuri, Dilip K.

    1990-01-01

    An apparatus designed to measure the coefficient of friction in certain controlled atmospheres is described. The coefficient of friction observed during high-load tests was nearly constant, with an average value of 0.56. This value is in general agreement with that found in the literature and also with the initial friction coefficient value of 0.67 measured during self-mated friction of 440C steel in an oxygen environment.

  14. Hafnium - material for chemical apparatus engineering

    International Nuclear Information System (INIS)

    Jennert, D.

    1981-01-01

    This work describes - on the background of available literature - the properties of hafnium in technical quality (DIN-material No. 2.6400) as material for chemical apparatus engineering. The occurence, refining, physical and chemical properties will be described as well as the material behavior. In conclusion, it has been found that there is, at present, sufficient information for the engineering of hafnium which has to be completed by additional investigations for special applications. (orig.) [de

  15. Singlet - oxygen therapy. 'MIT-S' apparatus

    International Nuclear Information System (INIS)

    Samosyuk, I.Z.; Chukhraev, N.V.; Pisanko, O.I.

    2003-01-01

    The described method is based on using singlet-oxygen mixture with antioxiding properties. This mixture is produced by photochemical sensibilization of air or water vapour in MIT-S apparatus. Technical parameters of MIT-S are presented. The method is used for therapy of different organs, for prophylactics, treatment and rehabilitation of a series of diseases (bronchial asthma, cardio-vascular, neurologic, sugar diabet, immune diseases)

  16. Capacity control of rotary vane apparatus

    International Nuclear Information System (INIS)

    Roberts, R. W.

    1985-01-01

    A capacity control arrangement for a rotary vane fluid displacement apparatus, such as a rotary vane compressor, having a vane retaining means that normally engages and retains the vanes in their retracted or nonworking position within the rotor defined guide slits of such rotary vane compressor. The retaining means are actuated to the vane-disengaged position by hydraulic control fluid which is communicated to the retaining means in response to an external parameter sensed by a control means

  17. Temperature-Control Apparatus For Hydrogen Maser

    Science.gov (United States)

    Vessot, R. F. C.; Mattison, E. M.

    1994-01-01

    Thermal-control apparatus maintains hydrogen maser at nearly constant temperature during long-term operational test. Designed to maintain, in small cylindrical vacuum tank containing maser, nearly isothermal condition when test conducted in air. Provides approximation of more nearly isothermal condition expected to be maintained in intended application, in which maser operated in vacuum environment and losses of heat reduced further by multilayer reflective insulation.

  18. Plasma/Neutral-Beam Etching Apparatus

    Science.gov (United States)

    Langer, William; Cohen, Samuel; Cuthbertson, John; Manos, Dennis; Motley, Robert

    1989-01-01

    Energies of neutral particles controllable. Apparatus developed to produce intense beams of reactant atoms for simulating low-Earth-orbit oxygen erosion, for studying beam-gas collisions, and for etching semiconductor substrates. Neutral beam formed by neutralization and reflection of accelerated plasma on metal plate. Plasma ejected from coaxial plasma gun toward neutralizing plate, where turned into beam of atoms or molecules and aimed at substrate to be etched.

  19. Orifice design for the control of coupled region flow

    International Nuclear Information System (INIS)

    Atherton, R.; Spadaro, P.R.; Brummerhop, F.G.

    1975-01-01

    A fluid system arrangement for nuclear reactors is described comprising a triplate orifice apparatus which simultaneously controls core flow distribution, flow rate ratio between hydraulically coupled regions of the blanket and radial static pressure gradients entering and leaving the blanket fuel region. The design of the apparatus is based on the parameters of the diameter of the orifice holes, the friction factor, and expansion, contraction and turning pressure loss coefficients of the geometry of each orifice region. These above parameters are properly matched to provide the desired pressure drop, flow split and negligible cross flow at the interface of standard and power-flattened open lattice blanket regions. (U.S.)

  20. Polarization imaging apparatus with auto-calibration

    Science.gov (United States)

    Zou, Yingyin Kevin; Zhao, Hongzhi; Chen, Qiushui

    2013-08-20

    A polarization imaging apparatus measures the Stokes image of a sample. The apparatus consists of an optical lens set, a first variable phase retarder (VPR) with its optical axis aligned 22.5.degree., a second variable phase retarder with its optical axis aligned 45.degree., a linear polarizer, a imaging sensor for sensing the intensity images of the sample, a controller and a computer. Two variable phase retarders were controlled independently by a computer through a controller unit which generates a sequential of voltages to control the phase retardations of the first and second variable phase retarders. A auto-calibration procedure was incorporated into the polarization imaging apparatus to correct the misalignment of first and second VPRs, as well as the half-wave voltage of the VPRs. A set of four intensity images, I.sub.0, I.sub.1, I.sub.2 and I.sub.3 of the sample were captured by imaging sensor when the phase retardations of VPRs were set at (0,0), (.pi.,0), (.pi.,.pi.) and (.pi./2,.pi.), respectively. Then four Stokes components of a Stokes image, S.sub.0, S.sub.1, S.sub.2 and S.sub.3 were calculated using the four intensity images.

  1. Maintenance and control of apparatus for radiotherapy

    International Nuclear Information System (INIS)

    Wakui, Sho

    1979-01-01

    In order to perform the safe operation of radiotherapy apparatuses and to secure the accuracy in positioning patients and in setting up radiation beam, proper checking-up and maintenance schedule is necessary. Such schedule is described briefly and also the mechanical or electrical equipments designed for securing the safety and accuracy or eliminating in adequate operation are explained, especially on treatment tables and accessories, such as wedge filters, irradiation field indicators and pointers, and the devices for observing patients. The structures and the practical control of the following equipments are explained; standard treatment table, treatment table with a lifting column by oil pressure, mobile positioning control pedestal, positioning control pendaut, mechanical fuse cutter for the safeguard of table height movement, safety interlock to protect table from physical contact with radiation head in rotation and safeguard for arms of a patient in longitudinal movement of treatment table. For the maintenance and control of wedge filters, the kind of filter angle in use, the direction of filter in use and whether filter is used or not are exactly confirmed by adequate display. The direction mechanism of radiation field and the pointers are required to be strict for exact focusing of radiation. Various control apparatuses and monitoring apparatuses are described. (Kobatake, H.)

  2. Polarization Imaging Apparatus with Auto-Calibration

    Science.gov (United States)

    Zou, Yingyin Kevin (Inventor); Zhao, Hongzhi (Inventor); Chen, Qiushui (Inventor)

    2013-01-01

    A polarization imaging apparatus measures the Stokes image of a sample. The apparatus consists of an optical lens set, a first variable phase retarder (VPR) with its optical axis aligned 22.5 deg, a second variable phase retarder with its optical axis aligned 45 deg, a linear polarizer, a imaging sensor for sensing the intensity images of the sample, a controller and a computer. Two variable phase retarders were controlled independently by a computer through a controller unit which generates a sequential of voltages to control the phase retardations of the first and second variable phase retarders. A auto-calibration procedure was incorporated into the polarization imaging apparatus to correct the misalignment of first and second VPRs, as well as the half-wave voltage of the VPRs. A set of four intensity images, I(sub 0), I(sub 1), I(sub 2) and I(sub 3) of the sample were captured by imaging sensor when the phase retardations of VPRs were set at (0,0), (pi,0), (pi,pi) and (pi/2,pi), respectively. Then four Stokes components of a Stokes image, S(sub 0), S(sub 1), S(sub 2) and S(sub 3) were calculated using the four intensity images.

  3. Method and apparatus for protection of pump systems

    International Nuclear Information System (INIS)

    Youngborg, L.H.

    1987-01-01

    This patent describes a nuclear power plant having a fluid-filler reactor vessel with a vapor outflow line for removing vapor from the reactor vessel, and liquid inflow means for injecting liquid to the reactor vessel. The inflow means includes an inflow line, a centrifugal pump disposed along the inflow line having an inlet and an outlet, an induction motor to drive the pump, flow control means along the inflow line between the pump and the reactor vessel from the pump. A means is included for generating a first control signal in response to liquid level in the reactor vessel and net vapor outflow versus liquid inflow with respect to the reactor vessel, the first control signal generating means being effective to generate a first signal to open and a second signal to close the flow control means to maintain liquid level in the vessel within predetermined limits. A pump and pump motor protection apparatus is described comprising: means for measuring the pressure of the liquid in the inlet of the pump; means for measuring the temperature of the liquid in the inlet of the pump; means for determining a required subcooling for the pump at the instantaneous temperature of the liquid in the inlet of the pump; and means for determining the enthalpy of the liquid in the inlet of the pump from the pressure and temperature of the liquid

  4. Copepod Behavior Response in an Internal Wave Apparatus

    Science.gov (United States)

    Webster, D. R.; Jung, S.; Haas, K. A.

    2017-11-01

    This study is motivated to understand the bio-physical forcing in zooplankton transport in and near internal waves, where high levels of zooplankton densities have been observed in situ. A laboratory-scale internal wave apparatus was designed to create a standing internal wave for various physical arrangements that mimic conditions observed in the field. A theoretical analysis of a standing internal wave inside a two-layer stratification system including non-linear wave effects was conducted to derive the expressions for the independent variables controlling the wave motion. Focusing on a case with a density jump of 1.0 σt, a standing internal wave was generated with a clean interface and minimal mixing across the pycnocline. Spatial and frequency domain measurements of the internal wave were evaluated in the context of the theoretical analysis. Behavioral assays with a mixed population of three marine copepods were conducted in control (stagnant homogeneous fluid), stagnant density jump interface, and internal wave flow configurations. In the internal wave treatment, the copepods showed an acrobatic, orbital-like motion in and around the internal wave region (bounded by the crests and the troughs of the waves). Trajectories of passive, neutrally-buoyant particles in the internal wave flow reveal that they generally oscillate back-and-forth along fixed paths. Thus, we conclude that the looping, orbital trajectories of copepods in the region near the internal wave interface are due to animal behavior rather than passive transport.

  5. Thermally-enhanced oil recovery method and apparatus

    Science.gov (United States)

    Stahl, Charles R.; Gibson, Michael A.; Knudsen, Christian W.

    1987-01-01

    A thermally-enhanced oil recovery method and apparatus for exploiting deep well reservoirs utilizes electric downhole steam generators to provide supplemental heat to generate high quality steam from hot pressurized water which is heated at the surface. A downhole electric heater placed within a well bore for local heating of the pressurized liquid water into steam is powered by electricity from the above-ground gas turbine-driven electric generators fueled by any clean fuel such as natural gas, distillate or some crude oils, or may come from the field being stimulated. Heat recovered from the turbine exhaust is used to provide the hot pressurized water. Electrical power may be cogenerated and sold to an electric utility to provide immediate cash flow and improved economics. During the cogeneration period (no electrical power to some or all of the downhole units), the oil field can continue to be stimulated by injecting hot pressurized water, which will flash into lower quality steam at reservoir conditions. The heater includes electrical heating elements supplied with three-phase alternating current or direct current. The injection fluid flows through the heater elements to generate high quality steam to exit at the bottom of the heater assembly into the reservoir. The injection tube is closed at the bottom and has radial orifices for expanding the injection fluid to reservoir pressure.

  6. Positioning calibration apparatus for transducers employed in nuclear reactor vessel inspection apparatus

    International Nuclear Information System (INIS)

    Elsner, H.J.

    1979-01-01

    Calibration apparatus for verifying the position and orientation of transducers used in nuclear reactor vessel inspection apparatus is disclosed. A tank, filled with water, the operating inspection medium, is fitted with a movable mounting assembly adapted to securely accommodate a transducer and the mounting assembly in which it is normally secured during an inspection procedure. The tank is also provided with a slidably mounted target positioned therein at a predetermined distance from the target which is selected to avoid the distortion effects in the near field of the transducer response. The calibration apparatus can be used to check the normal transducer mounting for either perpendicularity or angular orientation by moving the tank's mounting assembly via a lead screw with which it is threadingly engaged. 6 claims

  7. Correction of disorders in tissue perfusion, blood coagulation and fibrinolysis with Orbita apparatus on terahertz waves of cell metabolites

    Directory of Open Access Journals (Sweden)

    Vyacheslav F. Kirichuk

    2013-02-01

    Full Text Available This article contains information on principle of operation, technical parameters and possible application of Orbita {transliteration from Russian} apparatus for hemodynamic, fibrinolytic and peripheral perfusion disorders treatment. A single exposure to terahertz waves emitted by Orbita apparatus, corresponding to frequencies of molecular absorption and emission spectra of atmospheric oxygen (129.0 GHz, completely cures coagulant and fibrinolytic disorders of animals with acute immobilization stress. A course of treatment with electromagnetic waves corresponding to frequencies of molecular absorption and emission spectra of nitrogen oxide (150.176 – 150.664 leads to normalization of disrupted peripheral tissue perfusion parameters of animal undergoing treatment and stimulates basal and induced output of nitrogen oxide. This leads to decrease in peripheral vascular resistance to microcirculation and increase in blood flow to microvasculature. Experimental data provided in this article serves as a proof of viability of Orbita apparatus for treatment of coagulant, fibrinolytic and tissue perfusion disorders.

  8. Apparatus and method for treating pollutants in a gas using hydrogen peroxide and UV light

    Science.gov (United States)

    Cooper, Charles David (Inventor); Clausen, Christian Anthony (Inventor)

    2005-01-01

    An apparatus for treating pollutants in a gas may include a source of hydrogen peroxide, and a treatment injector for creating and injecting dissociated hydrogen peroxide into the flow of gas. The treatment injector may further include an injector housing having an inlet, an outlet, and a hollow interior extending therebetween. The inlet may be connected in fluid communication with the source of hydrogen peroxide so that hydrogen peroxide flows through the hollow interior and toward the outlet. At least one ultraviolet (UV) lamp may be positioned within the hollow interior of the injector housing. The at least one UV lamp may dissociate the hydrogen peroxide flowing through the tube. The dissociated hydrogen peroxide may be injected into the flow of gas from the outlet for treating pollutants, such as nitrogen oxides.

  9. Positioning calibration apparatus for transducers employed in nuclear reactor vessel inspection apparatus

    International Nuclear Information System (INIS)

    Elsner, H.J.

    1981-01-01

    The invention provides a calibration apparatus suitable for verifying the position and orientation of transducers used in reactor vessel ultrasonic inspection. The apparatus includes moveable mounting means which secures a transducer within the tank in its normal inspection orientation. A drive is also provided for moving the transducer in the tank relative to a target. The target is slidably positioned in the tank at a distance from the transducer which is selected to avoid the distortion effects in the near field of the transducer. The drive mechanism may be provided with graduated indicia of travel, or a scale may be affixed to the side of the tank. (L.L.)

  10. Method and apparatus for improved observation of in-situ combustion processes

    Science.gov (United States)

    Lee, D.O.; Montoya, P.C.; Wayland, J.R. Jr.

    Method and apparatus are provided for obtaining accurate dynamic measurements for passage of phase fronts through a core sample in a test fixture. Flow-through grid structures are provided for electrodes to permit data to be obtained before, during and after passage of a front there-through. Such electrodes are incorporated in a test apparatus for obtaining electrical characteristics of the core sample. With the inventive structure a method is provided for measurement of instabilities in a phase front progressing through the medium. Availability of accurate dynamic data representing parameters descriptive of material characteristics before, during and after passage of a front provides a more efficient method for enhanced recovery of oil using a fire flood technique. 6 figures, 2 tables.

  11. Development and commissioning of apparatus to investigate capillary phenomena using radiotracers

    International Nuclear Information System (INIS)

    Gunzel, F.; Craig, W.H.; Cruickshank, M.; Merrifield, C.M.

    2000-01-01

    A new technique and associated apparatus have been developed to measure the generation of a capillary fringe in a column of sand or silt in flight in the centrifuge. The novel use of very low concentrations of an effectively non-sorbing radioisotope (Technetium 99m) to label the pore fluid and to detect its presence has been developed from earlier research into the ion exchange capacity of this isotope flowing through a soil specimen. Initial research has shown that the moisture content is directly related to the activity measured by miniature Geiger Mueller detectors for a given bulk density of the soil specimen. The pore suctions in the vadose zone are measured by miniature commercially available tensiometers. This paper describes the apparatus, which combines these devices to measure, in real time, the moisture content and pore water suctions in the soil column at selected heights above a sustained water table level during the equilibration of the capillary zone in flight. (authors)

  12. Apparatus for production, measurement and reaction studies of dissociated gases at elevated temperatures

    Science.gov (United States)

    Christian, J. D.; Gilbreath, W. P.

    1975-01-01

    An apparatus is described which is used for the controlled production, characterization, and study of dissociated gases in a microwave discharge at elevated temperatures. A unique feature is the ability to produce and study a microwave discharge plasma in the heated zone. This allows elevated temperature reactions to be studied in high concentrations of dissociated gases. Further, the system permits weight change measurements of specimens in the plasma, thus facilitating reaction rate determinations. Included is a description of a cavity for use on a 50-mm diameter cylindrical reactor. The effects of flow rate, pressure, temperature, power, metal sample, and sampling position on dissociation percentage of oxygen in the apparatus are described as well as a technique for sample temperature measurements in the plasma which permits determination of high temperature recombination coefficients and reaction rates.

  13. Apparatus and method for atmospheric pressure reactive atom plasma processing for shaping of damage free surfaces

    Science.gov (United States)

    Carr,; Jeffrey, W [Livermore, CA

    2009-03-31

    Fabrication apparatus and methods are disclosed for shaping and finishing difficult materials with no subsurface damage. The apparatus and methods use an atmospheric pressure mixed gas plasma discharge as a sub-aperture polisher of, for example, fused silica and single crystal silicon, silicon carbide and other materials. In one example, workpiece material is removed at the atomic level through reaction with fluorine atoms. In this example, these reactive species are produced by a noble gas plasma from trace constituent fluorocarbons or other fluorine containing gases added to the host argon matrix. The products of the reaction are gas phase compounds that flow from the surface of the workpiece, exposing fresh material to the etchant without condensation and redeposition on the newly created surface. The discharge provides a stable and predictable distribution of reactive species permitting the generation of a predetermined surface by translating the plasma across the workpiece along a calculated path.

  14. An Apparatus for Facilitating the Manual Tabulation of Phytosociological Data

    Directory of Open Access Journals (Sweden)

    P. J. Müller

    1972-11-01

    Full Text Available Attempts by various continental workers to mechanize and facilitate compilation o f Braun- Blanquet phytosociological tables from raw data are shortly reviewed and a new apparatus for this purpose is described. The apparatus consists o f a table with aluminium channels in which different headed rivets can be placed, symbolizing cover-abundance values. With this apparatus phytosociological tables can be compiled in two stages.

  15. Nuclear fuel storage apparatus for seismic areas

    International Nuclear Information System (INIS)

    Anthony, A.J.

    1981-01-01

    An earthquake resistant apparatus is claimed for storing nuclear fuel within a water-filled pool wherein a structural grid which supports the fuel is in turn supported by cables from an upper elevation. The grid is located below the water level and spaced from the walls of the pool an amount, preferably at least equal to the anticipated earthquake displacement. The grid is located below the water level a sufficient depth for radiation shielding during fuel handling and storage, and tension members are preferably ten times the design earthquake displacement. A horizontal baffle is located around the periphery of the pool at an elevation above the grid

  16. Apparatus for cooling an electric machine

    Science.gov (United States)

    Palafox, Pepe; Gerstler, William Dwight; Shen, Xiaochun; El-Refaie, Ayman Mohamed Fawzi; Lokhandwalla, Murtuza; Salasoo, Lembit

    2013-07-16

    Provided is an apparatus, for example, for use with a rotating electric machine, that includes a housing. The housing can include a housing main portion and a housing end portion. The housing main portion can be configured to be disposed proximal to a body portion of a stator section of an electric machine. The housing main portion can define a main fluid channel that is configured to conduct fluid therethrough. The housing end portion can receive fluid from said main fluid channel and direct fluid into contact with a winding end portion of a conductive winding of the stator section.

  17. Apparatus and method for production of methanethiol

    Science.gov (United States)

    Agarwal, Pradeep K.; Linjewile, Temi M.; Hull, Ashley S.; Chen, Zumao

    2006-02-07

    A method for the production of methyl mercaptan is provided. The method comprises providing raw feed gases consisting of methane and hydrogen sulfide, introducing the raw feed gases into a non-thermal pulsed plasma corona reactor, and reacting the raw feed gases within the non-thermal pulsed plasma corona reactor with the reaction CH4+H2S.fwdarw.CH3SH+H2. An apparatus for the production of methyl mercaptan using a non-thermal pulsed plasma corona reactor is also provided.

  18. Apparatus for fabricating continuous lengths of superconductor

    Science.gov (United States)

    Kroeger, Donald M.; List, III, Frederick A.

    2001-01-01

    A process and apparatus for manufacturing a superconductor. The process is accomplished by depositing a superconductor precursor powder on a continuous length of a first substrate ribbon, overlaying a continuous length of a second substrate ribbon on said first substrate ribbon, and applying sufficient pressure to form a bound layered superconductor comprising a layer of said superconducting precursor powder between said first substrate ribbon and said second substrates ribbon. The layered superconductor is then heat treated to establish the superconducting phase of said superconductor precursor powder.

  19. Calibration apparatus for a machine-tool

    International Nuclear Information System (INIS)

    Crespin, G.

    1985-01-01

    The invention proposes a calibration apparatus for a machine-tool comprising a torque measuring device, where the tool is driven by a motor of which supply electric current is proportional to the torque applied upon the tool and can be controlled and measured, a housing having an aperture through which the rotatable tool can pass. This device alloys to apply a torque on the tool and to measure it from the supply current of the motor. The invention applies, more particularly to the screwing machines used for the mounting of the core containment plates [fr

  20. The golgi apparatus: two organelles in tandem.

    Science.gov (United States)

    Rothman, J E

    1981-09-11

    The Golgi apparatus consists of distinct cis and trans compartments that may act sequentially to refine the protein export of the endoplasmic reticulum by removing escaped endoplasmic reticulum proteins. Refinement may be a multistage process akin to fractional distillation; the stack of cisternae comprising the cis Golgi may be the plates in this distillation tower. The trans Golgi, consisting of the last one or two cisternae, may be the receiver that collects from the cis Golgi only its most refined fraction for later distribution to specific locations throughout the cell.

  1. ELECTROMAGNETIC APPARATUS FOR MOVING A ROD

    Science.gov (United States)

    Young, J.N.

    1958-04-22

    An electromagnetic apparatus for moving a rod-like member in small steps in either direction is described. The invention has particular application in the reactor field where the reactor control rods must be moved only a small distance and where the use of mechanical couplings is impractical due to the high- pressure seals required. A neutron-absorbing rod is mounted in a housing with gripping uaits that engage the rod, and coils for magnetizing the gripping units to make them grip, shift, and release the rod are located outside the housing.

  2. Method and apparatus for processing algae

    Science.gov (United States)

    Chew, Geoffrey; Reich, Alton J.; Dykes, Jr., H. Waite; Di Salvo, Roberto

    2012-07-03

    Methods and apparatus for processing algae are described in which a hydrophilic ionic liquid is used to lyse algae cells. The lysate separates into at least two layers including a lipid-containing hydrophobic layer and an ionic liquid-containing hydrophilic layer. A salt or salt solution may be used to remove water from the ionic liquid-containing layer before the ionic liquid is reused. The used salt may also be dried and/or concentrated and reused. The method can operate at relatively low lysis, processing, and recycling temperatures, which minimizes the environmental impact of algae processing while providing reusable biofuels and other useful products.

  3. A High Pressure Apparatus for Neutron Diffraction

    OpenAIRE

    Kazuo, Kamigaki; Hajime, Yoshida; Masayoshi, Ohashi; Takejiro, Kaneko; Kozaburo, Sato; The Research Institute for Iron, Steel and Other Metals; The Research Institute for Iron, Steel and Other Metals; The Research Institute for Iron, Steel and Other Metals; The Research Institute for Iron, Steel and Other Metals; Department of Physics, Faculty of Science, Hirosaki University

    1980-01-01

    A high pressure apparatus was developed for thermal neutron diffraction of time-of-flight method. The high pressure vessel was a piston-cylinder type, and Ti-Zr alloy was used as a material of the cylinder. The coherent scattering of neutron is suppressed in Ti-53wt% Zr alloy. The diffraction spectrum is formed of peaks from the specimen and a background, which corresponds to the energy distribution of the incident neutron. High pressure measurements were made in RbBr on the transformation be...

  4. Method and apparatus for simultaneous spectroelectrochemical analysis

    Science.gov (United States)

    Chatterjee, Sayandev; Bryan, Samuel A; Schroll, Cynthia A; Heineman, William R

    2013-11-19

    An apparatus and method of simultaneous spectroelectrochemical analysis is disclosed. A transparent surface is provided. An analyte solution on the transparent surface is contacted with a working electrode and at least one other electrode. Light from a light source is focused on either a surface of the working electrode or the analyte solution. The light reflected from either the surface of the working electrode or the analyte solution is detected. The potential of the working electrode is adjusted, and spectroscopic changes of the analyte solution that occur with changes in thermodynamic potentials are monitored.

  5. Method and apparatus for chemical synthesis

    Science.gov (United States)

    Kong; Peter C. , Herring; J. Stephen , Grandy; Jon D.

    2007-12-04

    A method and apparatus for forming a chemical hydride is described and which includes a pseudo-plasma-electrolysis reactor which is operable to receive a solution capable of forming a chemical hydride and which further includes a cathode and a movable anode, and wherein the anode is moved into and out of fluidic, ohmic electrical contact with the solution capable of forming a chemical hydride and which further, when energized produces an oxygen plasma which facilitates the formation of a chemical hydride in the solution.

  6. Apparatus and method for detecting explosives

    International Nuclear Information System (INIS)

    Griffith, B.

    1976-01-01

    An apparatus is described for use in situations such as airports to detect explosives hidden in containers (for eg. suitcases). The method involves the evaluation of the quantities of oxygen and nitrogen within the container by neutron activation analysis and the determination of whether these quantities exceed predetermined limits. The equipment includes a small sub-critical lower powered reactor for thermal (0.01 to 0.10 eV) neutron production, a radium beryllium primary source, a deuterium-tritium reactor as a high energy (> 1.06 MeV) neutron source and Geiger counter detector arrays. (UK)

  7. Apparatus for photon activation positron annihilation analysis

    Science.gov (United States)

    Akers, Douglas W [Idaho Falls, ID

    2007-06-12

    Non-destructive testing apparatus according to one embodiment of the invention comprises a photon source. The photon source produces photons having predetermined energies and directs the photons toward a specimen being tested. The photons from the photon source result in the creation of positrons within the specimen being tested. A detector positioned adjacent the specimen being tested detects gamma rays produced by annihilation of positrons with electrons. A data processing system operatively associated with the detector produces output data indicative of a lattice characteristic of the specimen being tested.

  8. Controlling the Internal Heat Transfer Coefficient by the Characteristics of External Flows

    Science.gov (United States)

    Zhuromskii, V. M.

    2018-01-01

    The engineering-physical fundamentals of substance synthesis in a boiling apparatus are presented. We have modeled a system of automatic stabilization of the maximum internal heat transfer coefficient in such an apparatus by the characteristics of external flows on the basis of adaptive seeking algorithms. The results of operation of the system in the shop are presented.

  9. Apparatus and Method for Ballistic Protection of Vehicle Undercarriages

    National Research Council Canada - National Science Library

    Gonzalez, Rene G

    2006-01-01

    .... In use, it is immediately positioned below a military vehicle to protect the crew compartment positioned above said apparatus by extending transversely between the propulsive means and laterally...

  10. Geotechnical deep ocean research apparatus (DORA)

    International Nuclear Information System (INIS)

    1986-01-01

    As part of the research programme on radioactive waste disposal in seabed geological formations, a Deep Ocean Research Apparatus (DORA) seabed machine has been conceptually designed and prototypes of principal subsystems built and tested by four DORA Project partners. The DORA is designed to operate in 6000 m of water and drive a string of test rods and a piezocone about 50 m into soft soil. Partner responsibility was Fugro for project management and the penetration apparatus; ISMES for data acquisition and control; Laboratorium voor Grondmechanica for the piezocone probe and its sensors; and Marine Structure Consultants for the mission profile and DORA handling requirements. The DORA will have a maximum thrust of 50 kN. The probe will measure cone resistance, sleeve friction, pore pressure and inclination. Stability on the seabed will be assisted by using a combination of polyester and polypropylene-nylon (double) braided rope. A continuous wheel-drive subsystem will drive the test rods. Gelled or lead-acid batteries can power a hydraulic powerpack. Acoustic data transmission will be used. Software for data processing automation has been tested with simulation of all input channels. Successful operation of subsystem prototypes indicates that a DORA can be constructed at any future time for use on fundamental or applied deep ocean science and seafloor engineering investigations by industry, government and universities

  11. Laboratory apparatus to evaluate microalgae production

    Directory of Open Access Journals (Sweden)

    L. R. S. Gris

    2013-09-01

    Full Text Available The application of microalgae for energy purposes and CO2 biomitigation continues to present a number of challenges, including the optimization of culture conditions. The application of experimental designs for microalgae cultivation is difficult, since experiments involving such microorganisms generally last days or weeks. This work proposes a multipurpose laboratory apparatus for the optimization of microalgae experimental conditions that simultaneously enables the evaluation of variables such as temperature, irradiance, photoperiod and CO2 concentration in the aeration stream, as well as variables related to the concentration of culture media nutrients. A case study is also presented in which temperature, concentration of f/2 medium sodium nitrate and the effects of incident light intensity on Nannochloropsis oculata lipid content are evaluated. Experiments were carried out following central composite designs, in batch cultivation within an airlift photobioreactor apparatus. The best experimental result was obtained at 21 ºC, 119 mg/L NaNO3 and 137 µE.m-2.s-1, corresponding to 41.8% lipids and 211.9 mg.L-1 final lipid concentrations.

  12. Data eye monitor method and apparatus

    Science.gov (United States)

    Gara, Alan G [Mount Kisco, NY; Marcella, James A [Rochester, MN; Ohmacht, Martin [Yorktown Heights, NY

    2012-01-31

    An apparatus and method for providing a data eye monitor. The data eye monitor apparatus utilizes an inverter/latch string circuit and a set of latches to save the data eye for providing an infinite persistent data eye. In operation, incoming read data signals are adjusted in the first stage individually and latched to provide the read data to the requesting unit. The data is also simultaneously fed into a balanced XOR tree to combine the transitions of all incoming read data signals into a single signal. This signal is passed along a delay chain and tapped at constant intervals. The tap points are fed into latches, capturing the transitions at a delay element interval resolution. Using XORs, differences between adjacent taps and therefore transitions are detected. The eye is defined by segments that show no transitions over a series of samples. The eye size and position can be used to readjust the delay of incoming signals and/or to control environment parameters like voltage, clock speed and temperature.

  13. Outer grid strap protruding spring repair apparatus

    International Nuclear Information System (INIS)

    Widener, W.H.

    1987-01-01

    This patent describes a nuclear fuel assembly grid spring repair apparatus for repairing a spring formed on an outer strap of a fuel assembly grid and having a portion protruding outwardly beyond the strap, the apparatus comprising: (a) a support frame defining an opening and having means defining a guide channel extending along the opening in a first direction; (b) means mounted on the frame and being adjustable for attaching the frame to the outer strap of the support grid so that the frame opening is aligned with the outwardly protruding spring on the outer strap; (c) an outer slide having a passageway defined therethrough and being mounted in the guide channel for reciprocable movement along the frame opening in the first direction for aligning the passageway with the outwardly protruding portion of the spring on the outer strap. The outer slide also has means defining a guide way extending along the passageway in a second direction generally orthogonal to the first direction; (d) a spring reset mechanism being operable for resetting the protruding spring to a nonprotruding position relative to the outer strap when the mechanism is aligned with the protruding portion of the spring; and (e) an inner slide supporting the spring reset mechanism and being mounted to the guide way for reciprocable movement along the passageway of the outer slide in the second direction for aligning the spring reset mechanism with the protruding portion of the spring on the outer strap

  14. Front lighted optical tooling method and apparatus

    International Nuclear Information System (INIS)

    Stone, W. J.

    1985-01-01

    An optical tooling method and apparatus uses a front lighted shadowgraphic technique to enhance visual contrast of reflected light. The apparatus includes an optical assembly including a fiducial mark, such as cross hairs, reflecting polarized light with a first polarization, a polarizing element backing the fiducial mark and a reflective surface backing the polarizing element for reflecting polarized light bypassing the fiducial mark and traveling through the polarizing element. The light reflected by the reflecting surface is directed through a second pass of the polarizing element toward the frontal direction with a polarization differing from the polarization of the light reflected by the fiducial mark. When used as a tooling target, the optical assembly may be mounted directly to a reference surface or may be secured in a mounting, such as a magnetic mounting. The optical assembly may also be mounted in a plane defining structure and used as a spherometer in conjunction with an optical depth measuring instrument. A method of measuring a radius of curvature of an unknown surface includes positioning the spherometer on a surface between the surface and a depth measuring optical instrument. As the spherometer is frontally illuminated, the distance from the depth measuring instrument to the fiducial mark and the underlying surface are alternately measured and the difference in these measurements is used as the sagittal height to calculate a radius of curvature

  15. Methods and apparatus for determining cardiac output

    Science.gov (United States)

    Cohen, Richard J. (Inventor); Mukkamala, Ramakrishna (Inventor); Sherman, Derin A. (Inventor)

    2010-01-01

    The present invention provides methods and apparatus for determining a dynamical property of the systemic or pulmonary arterial tree using long time scale information, i.e., information obtained from measurements over time scales greater than a single cardiac cycle. In one aspect, the invention provides a method and apparatus for monitoring cardiac output (CO) from a single blood pressure signal measurement obtained at any site in the systemic or pulmonary arterial tree or from any related measurement including, for example, fingertip photoplethysmography.According to the method the time constant of the arterial tree, defined to be the product of the total peripheral resistance (TPR) and the nearly constant arterial compliance, is determined by analyzing the long time scale variations (greater than a single cardiac cycle) in any of these blood pressure signals. Then, according to Ohm's law, a value proportional to CO may be determined from the ratio of the blood pressure signal to the estimated time constant. The proportional CO values derived from this method may be calibrated to absolute CO, if desired, with a single, absolute measure of CO (e.g., thermodilution). The present invention may be applied to invasive radial arterial blood pressure or pulmonary arterial blood pressure signals which are routinely measured in intensive care units and surgical suites or to noninvasively measured peripheral arterial blood pressure signals or related noninvasively measured signals in order to facilitate the clinical monitoring of CO as well as TPR.

  16. Capacitance dilatometry in a surface force apparatus

    International Nuclear Information System (INIS)

    Stewart, A.M.

    2003-01-01

    Full text: A variant of the surface force apparatus has been developed which enables measurements of the forces between opaque surfaces to be obtained. A capacitance dilatometry attachment for the surface force apparatus has been constructed in which the surface that moves under the influence of the applied force is attached to one plate of a capacitor whose capacitance thereby changes. In order to detect movements of 0.1 nm of the plates of a capacitor with gap 0.1 mm the capacitance has to be measured to one part in one million, noting further that the measured capacitance is several hundred times smaller than the associated stray capacitances. This resolution is achieved by means of a transformer ratio bridge and, provided that adequate vibration isolation can be achieved, displacements of 0.1 nm can be resolved reliably. This is the case even with air between the surfaces, air giving much less vibrational damping than liquids. The method has been applied to measure the forces between mica in electrolyte and to measure dispersion forces of mica and silica in air. In the latter case the results are of unprecedented accuracy for this technique and show unambiguously that for surface separations greater than 10 nm the retarded form of the dispersion force fits the measurements much better than the non-retarded form

  17. A laboratory apparatus to measure clast-bed contact forces

    Science.gov (United States)

    Cohen, D.

    2007-12-01

    Glacier dynamics, sediment transport, and erosion are controlled in part by processes occurring at the interface between basal ice and bedrock. One critical parameter is the contact force between a clast and the bedrock. This force affects many processes such as basal friction which regulates sliding speed, slip resistance which influences basal shear stress and may cause micro-seismic events associated with slip instabilities, abrasion which controls rates of erosion, landscape evolution, and production of sediments. Despite field and laboratory evidences indicating that contact forces may be up to one order of magnitude higher than estimated from leading theories, no studies have yet measured with precision the magnitude of contact forces and how contact forces vary as a function of key glaciological variables such as basal melt rate and effective pressure. An apparatus was designed to make two independent measurements: (1) the contact force between a clast and a hard bed as a function of melt rate and effective pressure; (2) the drag force on an identical clast away from the bed as a function of the ice speed. The contact force differs from the drag force because of the presence of the bed which modifies the ice flow field. Measurement (2) is necessary to estimate the rheological properties of the ice and to quantify wall- (bed) effects on the drag force. The apparatus consists of a hydraulic press that pressurizes an ice cylinder, 24~cm high and 20~cm in diameter, to 1.0 - 1.5~MPa. The ice cylinder is contained inside a polycarbonate vessel. Above and below the ice cylinder are three disks: an aluminum disk sandwiched between two Delrin disks. The aluminum disks are hollow and used to circulate a fluid at a controlled temperature. The Delrin disks are used to isolate the ice from the cold room and to control the flow of heat to the ice block. The ice is kept at the melting temperature by circulating a fluid in channels inside the polycarbonate vessel and in the

  18. Geophysical Fluid Flow Cell (GFFC) Simulation

    Science.gov (United States)

    1999-01-01

    These simulations of atmospheric flow use the same experimental parameters but started with slightly different initial conditions in the model. The simulations were part of data analysis for the Geophysical Fluid Flow Cell (GFFC), a planet in a test tube apparatus flown on Spacelab to mimic the atmospheres on gas giant planets and stars. (Credit: Dr. Tim Miller of Global Hydrology and Climate Center at the Marshall Space Flight Center)

  19. Apparatus and process for handling dangerous fluent material

    International Nuclear Information System (INIS)

    Stock, A.J.; Christofer, D.E.; Brinza, J.E.

    1979-01-01

    The invention provides apparatus for handling radioactive fluent material capable of emitting radioactivity, comprising a rigid shield wall of material and thickness sufficient to reduce substantially passage of radioactivity through the shield wall to a level that is not harmful to a human operator; operable handling means located at the side of the shield wall that is exposed to radioactivity from the fluent material for handling the fluent material, the handling means including means to introduce the fluent material into a container at the side of the shield wall and means for applying closure means to the container to close it after introduction therein of the fluent material, and means for controlling flow of the fluent material; power means for operating the handling means located on the other side of the shield wall that is not exposed to radioactivity from the fluent material; and movable mechanical means for driving the handling means extending through the shield wall to operate the handling means from the power means without such harmful passage of radioactivity through the shield wall

  20. Method and Apparatus for Measuring Thermal Conductivity of Small, Highly Insulating Specimens

    Science.gov (United States)

    Miller, Robert A (Inventor); Kuczmarski, Maria A (Inventor)

    2013-01-01

    A method and apparatus for the measurement of thermal conductivity combines the following capabilities: 1) measurements of very small specimens; 2) measurements of specimens with thermal conductivity on the same order of that as air; and, 3) the ability to use air as a reference material. Care is taken to ensure that the heat flow through the test specimen is essentially one-dimensional. No attempt is made to use heated guards to minimize the flow of heat from the hot plate to the surroundings. Results indicate that since large correction factors must be applied to account for guard imperfections when specimen dimensions are small, simply measuring and correcting for heat from the heater disc that does not flow into the specimen is preferable.

  1. 47 CFR 32.6311 - Station apparatus expense.

    Science.gov (United States)

    2010-10-01

    ... SYSTEM OF ACCOUNTS FOR TELECOMMUNICATIONS COMPANIES Instructions for Expense Accounts § 32.6311 Station apparatus expense. This account shall include expenses associated with station apparatus. Expenses associated with company internal use communication equipment shall be recorded in Account 6123, Office...

  2. Apparatus as Milestones in the History of Comparative Psychology

    Science.gov (United States)

    Washburn, David A.; Rumbaugh, Duane M.; Putney, R. Thompson

    1994-01-01

    Significant apparatus developments from the history of comparative psychology are reviewed, including the contemporary trend toward computer use in research with nonhuman animals. It is argued that milestone apparatus served not only to open new lines of inquiry but also to shape or delimit the nature of the answers that were obtained.

  3. A New Sand-Culture Apparatus for Tree Nutrition Research

    Science.gov (United States)

    B. G. Blackmon; N. E. Linnartz

    1970-01-01

    Research in tree nutrition often necessitates the use of rather large-scale installations of sand-culture equipment. The apparatus described below was developed during the course of experiments at Louisiana State University and provided daily irrigation to 102 culture units of loblolly pine (Pinus taeda L.) for a period of 10 months. This apparatus is a modification of...

  4. Past and present of measuring apparatus for nuclear medicine

    International Nuclear Information System (INIS)

    Murayama, Hideo

    2013-01-01

    The history of advancement of measuring apparatus for nuclear medicine is looked back. It is presented that Japanese contribution to these advancement has been in no small quantities. The future view carrying the measuring apparatus for nuclear medicine is also described. (M.H.)

  5. Apparatus for the automatic determination of oxygen consumption in ...

    African Journals Online (AJOL)

    APPARATUS FOR THE AUTOMATIC DETERMINATION OF OXYGEN. CONSUMPTION IN FISH l. F. !C. MARAIS, A. F. A. AlCBRS and P. VAN DEI. RYST. Department o/Zoology, U"iversity 0/ Port Elizabeth. ABSTRACT. An apparatus is described which permits the automatic determination of the oxygen consumption of three ...

  6. Apparatus for the laser ablative synthesis of carbon nanotubes

    Science.gov (United States)

    Smith, Michael W.; Jordan, Kevin

    2010-02-16

    An RF-induction heated side-pumped synthesis chamber for the production of carbon nanotubes. Such an apparatus, while capable of producing large volumes of carbon nanotubes, concurrently provides a simplified apparatus that allows for greatly reduced heat up and cool down times and flexible flowpaths that can be readily modified for production efficiency optimization.

  7. Simple and Low-Cost Exposed -Layer Grain Drying Apparatus ...

    African Journals Online (AJOL)

    Thin-layer drying apparatus was developed from standard “off-the- shelf” equipment: a fan convection laboratory oven and a weighing scale. Using this apparatus the thin-layer drying data for wheat under constant conditions were obtained for a range of drying air temperature from 30°C to 150°C and the initial moisture ...

  8. Method for Surface Scanning in Medical Imaging and Related Apparatus

    DEFF Research Database (Denmark)

    2015-01-01

    A method and apparatus for surface scanning in medical imaging is provided. The surface scanning apparatus comprises an image source, a first optical fiber bundle comprising first optical fibers having proximal ends and distal ends, and a first optical coupler for coupling an image from the image...

  9. Experimental and modeling study of thermal exposure of a self-contained breathing apparatus (SCBA).

    Science.gov (United States)

    Donnelly, Michelle K; Yang, Jiann C

    2015-08-01

    An experimental apparatus designed to study firefighter safety equipment exposed to a thermal environment was developed. The apparatus consisted of an elevated temperature flow loop with the ability to heat the air stream up to 200°C. The thermal and flow conditions at the test section were characterized using thermocouples and bi-directional probes. The safety equipment examined in this study was a self-contained breathing apparatus (SCBA), including a facepiece and an air cylinder. The SCBA facepiece was placed on a mannequin headform and coupled to a breathing simulator that was programmed with a prescribed breathing pattern. The entire SCBA assembly was placed in the test section of the flow loop for these thermal exposure experiments. Three air stream temperatures, 100°C, 150°C, and 200°C, were used with the average air speed at the test section set at 1.4m/s and thermal exposure durations up to 1200 s. Measurements were made using type-K bare-bead thermocouples located in the mannequin's mouth and on the outer surface of the SCBA cylinder. The experimental results indicated that increasing the thermal exposure severity and duration increased the breathing air temperatures supplied by the SCBA. Temperatures of breathing air from the SCBA cylinder in excess of 60°C were observed over the course of the thermal exposure conditions used in most of the experiments. A mathematical model for transient heat transfer was developed to complement the thermal exposure experimental study. The model took into consideration forced convective heat transfer, quasi-steady heat conduction through the composite layers of the SCBA cylinder wall, the breathing pattern and action of the breathing simulator, and predicted air temperatures from the thermally exposed SCBA cylinder and temperatures at the outer surface of the SCBA cylinder. Model predictions agreed reasonably well with the experimental measurements. Published by Elsevier Ltd.

  10. Construction of apparatus for curing by electron irradiation and its characteristics

    International Nuclear Information System (INIS)

    Kasai, Noboru; Nishii, Masanobu; Seguchi, Tadao

    1991-04-01

    An apparatus was designed and constructed for electron irradiation curing treatments of organic silicone fibers as the precursor of silicon carbide (SiC) fibers. Using the apparatus, the organic silicone fibers were cured by electron beam crosslinking, and the active species formed were quenched by heating up to 1173 K (900degC) in oxygen free atmosphere. This apparatus is composed of two sample trays, irradiation chamber, middle container, heating container, electric furnace, and vacuum pump. The sample tray is moved from irradiation chamber to heating container through the middle container. Irradiation chamber, middle container and heating container are separated by airtight shutters. It was observed that the air leak is negligible, and the oxidation was well prevented during the radiation curing. The absorbed dose was 14.4 kGy per double pass by using electron beam of 2MeV and 1mA with 100 cm/min of sample tray moving speed. The temperature rise of sample by electron irradiation was depressed by Helium gas flow and with the supply of liquid nitrogen to the radiator inside of irradiation container. The temperature in the heating container showed rather large distribution at the higher temperature. (author)

  11. Development of the medical apparatus for Doppler-controlled treatment of hemorrhoids using laser coagulation

    Directory of Open Access Journals (Sweden)

    Nikolay A. Gryaznov

    2017-12-01

    Full Text Available In the article authors present the concept of the surgical manipulator delivering laser radiation to the target area. For the implementation of Doppler-controlled treatment of hemorrhoids by laser coagulation, an important circumstance is the necessity to realize by means of the dopplerograph the possibility of controlling the efficiency of coagulation of the pathological vessel immediately after the impact, which will create the prerequisites for the formation of a program cycle with the inclusion of control elements by feedback. In this regard, the structure of the laser medical apparatus is developed, which allows determining the location, size and flow of arterial and venous vessels, performing laser coagulation of pathologically damaged sites under constant Doppler control. The developed adaptive power management system includes several functional units for the processing of the data from ultrasound scanner and the Doppler. Medical apparatus for minimally invasive treatment of hemorrhoids based on the laser coagulator and ultrasound Doppler will allow performing surgeries in automated and half-automated modes. The suggested medical apparatus helps to determine pathological vessels, choose the required radiation mode and provides vessel obliteration. Successful realization of constructive combination of real-time diagnostics and surgical manipulation with a laser can result in a unique minimally invasive solution to treat hemorrhoids that currently doesn’t have analogues.

  12. Apparatus for concentrating by dual temperature exchange

    International Nuclear Information System (INIS)

    Spevack, J.S.

    1975-01-01

    The dual temperature exchange apparatus, with a dual temperature stage having a hot processing tower and a cold processing tower, is provided with means for transferring heat from the hot processed gas to both liquid and gas being delivered to the hot processing tower. The heat exchange system provides means for effecting direct contact between the hot processed gas and the cold processed liquid being delivered to the hot tower, means for establishing a circulation of the resulting heated processed liquid, and means including an indirect contact exchanger for transferring heat from said circulation to condition the gas being supplied to the hot processing tower. The reactants in the example given are hydrogen sulfide gas and liquid water

  13. Casimir apparatuses in a weak gravitational field

    DEFF Research Database (Denmark)

    Bimonte, Giuseppe; Calloni, Enrico; Esposito, Giampiero

    2009-01-01

    We review and assess a part of the recent work on Casimir apparatuses in the weak gravitational field of the Earth. For a free, real massless scalar field subject to Dirichlet or Neumann boundary conditions on the parallel plates, the resulting regularized and renormalized energy-momentum tensor...... is covariantly conserved, while the trace anomaly vanishes if the massless field is conformally coupled to gravity. Conformal coupling also ensures a finite Casimir energy and finite values of the pressure upon parallel plates. These results have been extended to an electromagnetic field subject to perfect...... conductor (hence idealized) boundary conditions on parallel plates, by various authors. The regularized and renormalized energy-momentum tensor has beene valuated up to second order in the gravity acceleration. In both the scalar and the electromagnetic case, studied to first order in the gravity...

  14. A high pressure apparatus for neutron diffraction

    International Nuclear Information System (INIS)

    Kamigaki, Kazuo; Yoshida, Hajime; Ohashi, Masayoshi; Kaneko, Takejiro; Sato, Kozaburo.

    1980-01-01

    A high pressure apparatus was developed for thermal neutron diffraction of time-of-flight method. The high pressure vessel was a piston-cylinder type, and Ti-Zr alloy was used as a material of the cylinder. The coherent scattering of neutron is suppressed in Ti-53wt% Zr alloy. The diffraction spectrum is formed of peaks from the specimen and a background, which corresponds to the energy distribution of the incident neutron. High pressure measurements were made in RbBr on the transformation between NaCl-type structure and CsCl-type to a pressure about 20 kb, and a good agreement was confirmed with former experiments. (author)

  15. Apparatus for silicon nitride precursor solids recovery

    Science.gov (United States)

    Crosbie, Gary M.; Predmesky, Ronald L.; Nicholson, John M.

    1995-04-04

    Method and apparatus are provided for collecting reaction product solids entrained in a gaseous outflow from a reaction situs, wherein the gaseous outflow includes a condensable vapor. A condensate is formed of the condensable vapor on static mixer surfaces within a static mixer heat exchanger. The entrained reaction product solids are captured in the condensate which can be collected for further processing, such as return to the reaction situs. In production of silicon imide, optionally integrated into a production process for making silicon nitride caramic, wherein reactant feed gas comprising silicon halide and substantially inert carrier gas is reacted with liquid ammonia in a reaction vessel, silicon imide reaction product solids entrained in a gaseous outflow comprising residual carrier gas and vaporized ammonia can be captured by forming a condensate of the ammonia vapor on static mixer surfaces of a static mixer heat exchanger.

  16. Apparatus and method for pyroelectric power conversion

    Science.gov (United States)

    Olsen, R.B.

    1984-01-10

    Apparatus and method for converting heat to electrical energy by the use of one or more capacitors having temperature dependent capacitance are disclosed. The capacitor is cycled between relatively high and relatively low temperatures by successive thermal contact with relatively high and relatively low temperature portions of a heat transfer medium having a temperature gradient therein. Upon heating of the capacitor, the capacitance thereof is reduced, so that a charge therein is caused to expand into associated external circuitry in which it is available to do electrical work. The capacitor is then cooled and recharged and the cycle is repeated. The electrical output of the capacitor results from the regenerative delivery of heat to and removal of heat from the capacitor by the heat transfer medium, and efficient conversion of heat to electric energy is thereby effected. 12 figs.

  17. Method and apparatus for inspecting tires

    International Nuclear Information System (INIS)

    Fox, R.L.T.

    1975-01-01

    A method and apparatus for inspecting tires by the use of x-rays is disclosed in which a tire is advanced to an inspection station, engaged along opposite bead rims and inflated to axially spread the bead rims and side walls. An x-ray source is advanced axially into the tire and the tire is eccentrically rotated relative to the x-ray source to enable radial positioning of the source relative to the tire near the tire bead rim diameter without requiring radial movement of the x-ray source. The x-ray source produces an x-ray beam which sweeps about the interior of the expanded tire from bead rim to bead rim while the tire is rotated about its centerline. An x-ray detection system detects x-rays which have penetrated the wall and produces inspection information concerning the tire construction. (Patent Office Record)

  18. Apparatus for irradiation with electron beam

    International Nuclear Information System (INIS)

    Uehara, K.; Ito, A.; Nishimune, K.; Fujita, K.

    1976-01-01

    An irradiation apparatus with high energy electrons is disclosed in which a wire shaped or linear object to be irradiated is moved back and forth many times under an electron window so as to irradiate it with an electron beam. According to one feature of the invention, an electron beam, which leaks through gaps between the objects to be irradiated or which penetrates the objects to be irradiated, is reversed by a magnetic field approximately perpendicular to the scanning face of the electron beam by means of a magnet which is disposed under the objects to be irradiated, and the reversed electron beam is thereby again applied to the objects to be irradiated. A high utilization rate of the electron beam is accomplished, and the objects can be thereby uniformly irradiated with the electron beam. 4 claims, 6 drawing figures

  19. Multiple sample, radioactive particle counting apparatus

    International Nuclear Information System (INIS)

    Reddy, R.R.V.; Kelso, D.M.

    1978-01-01

    An apparatus is described for determining the respective radioactive particle sample count being emitted from radioactive particle containing samples. It includes means for modulating the information on the radioactive particles being emitted from the samples, coded detecting means for sequentially detecting different respective coded combinations of the radioactive particles emitted from more than one but less than all of the samples, and processing the modulated information to derive the sample count for each sample. It includes a single light emitting crystal next to a number of samples, an encoder belt sequentially movable between the crystal and the samples. The encoder belt has a coded array of apertures to provide corresponding modulated light pulses from the crystal, and a photomultiplier tube to convert the modulated light pulses to decodable electrical signals for deriving the respective sample count

  20. Automatic control of oscillatory penetration apparatus

    Science.gov (United States)

    Lucon, Peter A

    2015-01-06

    A system and method for controlling an oscillatory penetration apparatus. An embodiment is a system and method for controlling a sonic drill having a displacement and an operating range and operating at a phase difference, said sonic drill comprising a push-pull piston and eccentrics, said method comprising: operating the push-pull piston at an initial push-pull force while the eccentrics are operated at a plurality of different operating frequencies within the operating range of the sonic drill and measuring the displacement at each operating frequency; determining an efficient operating frequency for the material being drilled and operating the eccentrics at said efficient operating frequency; determining the phase difference at which the sonic drill is operating; and if the phase difference is not substantially equal to minus ninety degrees, operating the push-pull piston at another push-pull force.

  1. Method and apparatus for charged particle propagation

    Science.gov (United States)

    Hershcovitch, A.

    1996-11-26

    A method and apparatus are provided for propagating charged particles from a vacuum to a higher pressure region. A generator includes an evacuated chamber having a gun for discharging a beam of charged particles such as an electron beam or ion beam. The beam is discharged through a beam exit in the chamber into a higher pressure region. A plasma interface is disposed at the beam exit and includes a plasma channel for bounding a plasma maintainable between a cathode and an anode disposed at opposite ends thereof. The plasma channel is coaxially aligned with the beam exit for propagating the beam from the chamber, through the plasma, and into the higher pressure region. The plasma is effective for pumping down the beam exit for preventing pressure increase in the chamber and provides magnetic focusing of the beam discharged into the higher pressure region 24. 7 figs.

  2. Solar energy apparatus with apertured shield

    Science.gov (United States)

    Collings, Roger J. (Inventor); Bannon, David G. (Inventor)

    1989-01-01

    A protective apertured shield for use about an inlet to a solar apparatus which includesd a cavity receiver for absorbing concentrated solar energy. A rigid support truss assembly is fixed to the periphery of the inlet and projects radially inwardly therefrom to define a generally central aperture area through which solar radiation can pass into the cavity receiver. A non-structural, laminated blanket is spread over the rigid support truss in such a manner as to define an outer surface area and an inner surface area diverging radially outwardly from the central aperture area toward the periphery of the inlet. The outer surface area faces away from the inlet and the inner surface area faces toward the cavity receiver. The laminated blanket includes at least one layer of material, such as ceramic fiber fabric, having high infra-red emittance and low solar absorption properties, and another layer, such as metallic foil, of low infra-red emittance properties.

  3. Experiences with decontaminating tritium-handling apparatus

    International Nuclear Information System (INIS)

    Maienschein, J.L.; Garcia, F.; Garza, R.G.; Kanna, R.L.; Mayhugh, S.R.; Taylor, D.T.

    1992-01-01

    Tritium-handling apparatus has been decontaminated as part of the downsizing of the LLNL Tritium Facility. Two stainless-steel glove boxes that had been used to process lithium deuteride-tritide (LiDT) slat were decontaminated using the Portable Cleanup System so that they could be flushed with room air through the facility ventilation system. In this paper the details on the decontamination operation are provided. A series of metal (palladium and vanadium) hydride storage beds have been drained of tritium and flushed with deuterium, in order to remove as much tritium as possible. The bed draining and flushing procedure is described, and a calculational method is presented which allows estimation of the tritium remaining in a bed after it has been drained and flushed. Data on specific bed draining and flushing are given

  4. Method and apparatus for analyzing ionizable materials

    International Nuclear Information System (INIS)

    Ehrlich, B.J.; Hall, R.C.; Thiede, P.W.

    1979-01-01

    An apparatus and method are described for analyzing a solution of ionizable compounds in a liquid. The solution is irradiated with electromagnetic radiation to ionize the compounds and the electrical conductivity of the solution is measured. The radiation may be X-rays, ultra-violet, infra-red or microwaves. The solution may be split into two streams, only one of which is irradiated, the other being used as a reference by comparing conductivities of the two streams. The liquid must be nonionizable and is preferably a polar solvent. The invention provides an analysis technique useful in liquid chromatography and in gas chromatography after dissolving the eluted gases in a suitable solvent. Electrical conductivity measurements performed on the irradiated eluent provide a quantitative indication of the ionizable materials existing within the eluent stream and a qualitative indication of the purity of the eluent stream. (author)

  5. The quantum X-ray radiology apparatus

    CERN Document Server

    Hilt, B; Prevot, G

    2000-01-01

    The paper entitled 'New Quantum Detection System for Very Low Dose X-ray Radiology', presented at the talk session, discusses the preliminary data obtained using a new quantum X-ray radiology system with a high-efficiency solid-state detector and highly sensitive electronics, making it possible to reduce significantly the dose administered to a patient in X-ray radiology examinations. The present paper focuses more on the technological aspects of the apparatus, such as the integration of the detector with the two Asics, and the computer system. Namely, it is shown how the computer system calibrates the detection system, acquires the data in real time, and controls the scan parameters and image filtering process.

  6. APPARATUS AND METHOD FOR ARC WELDING

    Science.gov (United States)

    Noland, R.A.; Stone, C.C.

    1960-05-10

    An apparatus and method are given for forming a welding arc which is rotated by a magnetic field very rapidly about an annular electrode so that a weld is produced simultaneously over all points of an annular or closed path. This invention inhibits outgassing from the jacket of a fuel slug which is being welded by adjusting the pressure throughout the welding cycle to establish a balance between the gas pressure within the jacket and that of the atmosphere surrounding the jacket. Furthermore, an improved control of the magnetic field producing rotation of the welding arc is disclosed whereby this rotation is prevented from splashing about the metal being welded as the welding arc makes it molten.

  7. High pressure and high temperature apparatus

    Science.gov (United States)

    Voronov, Oleg A.

    2005-09-13

    A design for high pressure/high temperature apparatus and reaction cell to achieve .about.30 GPa pressure in .about.1 cm volume and .about.100 GPa pressure in .about.1 mm volumes and 20-5000.degree. C. temperatures in a static regime. The device includes profiled anvils (28) action on a reaction cell (14, 16) containing the material (26) to be processed. The reaction cell includes a heater (18) surrounded by insulating layers and screens. Surrounding the anvils are cylindrical inserts and supporting rings (30-48) whose hardness increases towards the reaction cell. These volumes may be increased considerably if applications require it, making use of presses that have larger loading force capability, larger frames and using larger anvils.

  8. Method and apparatuses for ion cyclotron spectrometry

    Science.gov (United States)

    Dahl, David A [Idaho Falls, ID; Scott, Jill R [Idaho Falls, ID; McJunkin, Timothy R [Idaho Falls, ID

    2012-03-06

    An ion cyclotron spectrometer may include a vacuum chamber that extends at least along a z-axis and means for producing a magnetic field within the vacuum chamber so that a magnetic field vector is generally parallel to the z-axis. The ion cyclotron spectrometer may also include means for producing a trapping electric field within the vacuum chamber. The trapping electric field may comprise a field potential that, when taken in cross-section along the z-axis, includes at least one section that is concave down and at least one section that is concave up so that ions traversing the field potential experience a net magnetron effect on a cyclotron frequency of the ions that is substantially equal to zero. Other apparatuses and a method for performing ion cyclotron spectrometry are also disclosed herein.

  9. Methods and apparatuses for deoxygenating pyrolysis oil

    Science.gov (United States)

    Baird, Lance Awender; Brandvold, Timothy A.; Frey, Stanley Joseph

    2017-09-12

    Methods and apparatuses are provided for deoxygenating pyrolysis oil. A method includes contacting a pyrolysis oil with a deoxygenation catalyst in a first reactor at deoxygenation conditions to produce a first reactor effluent. The first reactor effluent has a first oxygen concentration and a first hydrogen concentration, based on hydrocarbons in the first reactor effluent, and the first reactor effluent includes an aromatic compound. The first reactor effluent is contacted with a dehydrogenation catalyst in a second reactor at conditions that deoxygenate the first reactor effluent while preserving the aromatic compound to produce a second reactor effluent. The second reactor effluent has a second oxygen concentration lower than the first oxygen concentration and a second hydrogen concentration that is equal to or lower than the first hydrogen concentration, where the second oxygen concentration and the second hydrogen concentration are based on the hydrocarbons in the second reactor effluent.

  10. Starting apparatus for internal combustion engines

    Science.gov (United States)

    Dyches, Gregory M.; Dudar, Aed M.

    1997-01-01

    An internal combustion engine starting apparatus uses a signal from a curt sensor to determine when the engine is energized and the starter motor should be de-energized. One embodiment comprises a transmitter, receiver, computer processing unit, current sensor and relays to energize a starter motor and subsequently de-energize the same when the engine is running. Another embodiment comprises a switch, current transducer, low-pass filter, gain/comparator, relay and a plurality of switches to energize and de-energize a starter motor. Both embodiments contain an indicator lamp or speaker which alerts an operator as to whether a successful engine start has been achieved. Both embodiments also contain circuitry to protect the starter and to de-energize the engine.

  11. Seal Apparatus and Methods to Manufacture Thereof

    Science.gov (United States)

    Richard, James A. (Inventor)

    2013-01-01

    In some implementations, apparatus and methods are provided through which a dynamic cryogenic seal is manufactured. In some implementations, the seal includes a retainer and a spring-seal assembly, the assembly being comprised of a main spring housing and fluorine-containing polymer seals. In some implementations, either a radial seal, or an axial (or "piston seal") is provided. In some implementations, methods of manufacturing the dynamic cryogenic seal are also provided. In some implementations, the methods include assembling the components while either heated or cooled, taking advantage of thermal expansion and contraction, such that there is a strong interference fit between the components at room temperature. In some implementations, this process ensures that the weaker fluorine-containing polymer seal is forced to expand and contract with the stronger retainer and spring and is under constant preload. In some implementations, the fluorine-containing polymer is therefore fluidized and retained, and can not lift off.

  12. Mathematical model of integrated thermal apparatus

    Directory of Open Access Journals (Sweden)

    Katarína Mikulová Polčová

    2010-03-01

    Full Text Available Mathematical model for the integrated thermal apparatus was developed. It consists of program modules from which individualfurnace model can be generated. For the model generation elementary balance method was used. Generation of the individual modelincludes model formulation and parameters determination. Model formulation is based on first principles, heuristics and empirical results.Parameters determination is generally based on priory information, but it has to take into account specific conditions. The developed modelwas adapted for real time applications. For quantitative application developed model has to be calibrated. For the calibration theoperational furnace can be used. For model calibration of not existing furnace the priory knowledge and physical model can be used.Presented model was calibrated on experimental furnace. The results were gained by simulations.

  13. Eddy current separation apparatus, separation module, separation method and method for adjusting an eddy current separation apparatus

    NARCIS (Netherlands)

    Rem, P.C.; Bakker, M.C.M.; Berkhout, S.P.M.; Rahman, M.A.

    2012-01-01

    Eddy current separation apparatus (1) for separating particles (20) from a particle stream (w), wherein the apparatus (1) comprises a separator drum (4) adapted to create a first particle fraction (21) and a second particle fraction (23), a feeding device (2) upstream of the separator drum (4) for

  14. Flow Rounding

    OpenAIRE

    Kang, Donggu; Payor, James

    2015-01-01

    We consider flow rounding: finding an integral flow from a fractional flow. Costed flow rounding asks that we find an integral flow with no worse cost. Randomized flow rounding requires we randomly find an integral flow such that the expected flow along each edge matches the fractional flow. Both problems are reduced to cycle canceling, for which we develop an $O(m \\log(n^2/m))$ algorithm.

  15. Portable pulse X-ray apparatus with gas insulation

    CERN Document Server

    Avilov, E A; Kanunov, I M

    2001-01-01

    There are presented the data on development,investigation and application of a pulse X-ray apparatus with gas insulation.There are described circuit and design solutions for a 90 kV apparatus to be used in medical X-ray diagnostics and 200 kV apparatus to be applied for the researches of high-speed processes.There are demonstrated the advantages of using gas under pressure as insulating medium.There are presented basic output characteristics of the devices.

  16. Apparatus to simulate nuclear heating in advanced fuels

    International Nuclear Information System (INIS)

    Wrona, B.J.; Galvin, T.M.; Johanson, E.

    1976-10-01

    A direct-electrical-heating apparatus has been built to simulate in-reactor temperature gradients and heating conditions in both the mixed nitrides and carbides of uranium and plutonium. The apparatus has the capability for the investigation and direct observation of fuel-behavior phenomena that should significantly enlarge the data base on mixed carbides and nitrides at temperatures near and above their melting points. In addition to heating UC, results of prooftests showed that the apparatus has the capability to heat graphite, 30 vol % ZrC in graphite, B 4 C control-rod pellets, and stainless steel

  17. Article separation apparatus and method for unit operations

    Science.gov (United States)

    Pardini, Allan F.; Gervais, Kevin L.; Mathews, Royce A.; Hockey, Ronald L.

    2010-06-22

    An apparatus and method are disclosed for separating articles from a group of articles. The apparatus includes a container for containing one or more articles coupled to a suitable fluidizer for suspending articles within the container and transporting articles to an induction tube. A portal in the induction tube introduces articles singly into the induction tube. A vacuum pulls articles through the induction tube separating the articles from the group of articles in the container. The apparatus and method can be combined with one or more unit operations or modules, e.g., for inspecting articles, assessing quality of articles, or ascertaining material properties and/or parameters of articles, including layers thereof.

  18. Method and Apparatus for Concentrating Vapors for Analysis

    Science.gov (United States)

    Grate, Jay W.; Baldwin, David L.; Anheier, Jr., Norman C.

    2008-10-07

    An apparatus and method are disclosed for pre-concentrating gaseous vapors for analysis. The invention finds application in conjunction with, e.g., analytical instruments where low detection limits for gaseous vapors are desirable. Vapors sorbed and concentrated within the bed of the apparatus can be thermally desorbed achieving at least partial separation of vapor mixtures. The apparatus is suitable, e.g., for preconcentration and sample injection, and provides greater resolution of peaks for vapors within vapor mixtures, yielding detection levels that are 10-10,000 times better than for direct sampling and analysis systems. Features are particularly useful for continuous unattended monitoring applications.

  19. Apparatus Producing an Even Distribution of Strain into Carries

    Science.gov (United States)

    Hrabovský, Leopold

    2017-10-01

    In many high-rise residential buildings or multi-storey warehouses, machinery, so called lifts, is used for the vertical transportation of people or weights between two or more altitudinally distant places. Carriers used for lifts are steel ropes or sprocket chains, on which a cage or a counterbalance is hinged. Apparatus of all carriers, attached to the hinge of the cage or counterbalance, should be even. This can be made only by hammer hinge. Fixed or springe hinge cannot be a perfect equalizing apparatus. This article describes an apparatus, which allows an even distribution of the strain into lift carriers, which use springe hinge of carrier ropes.

  20. Thin film production method and apparatus

    Science.gov (United States)

    Loutfy, Raouf O.; Moravsky, Alexander P.; Hassen, Charles N.

    2010-08-10

    A method for forming a thin film material which comprises depositing solid particles from a flowing suspension or aerosol onto a filter and next adhering the solid particles to a second substrate using an adhesive.

  1. [Development of electroforming apparatus for coronal restoration].

    Science.gov (United States)

    Watanabe, M; Sawada, T; Ukiya, M

    1989-03-01

    As dental technologies become highly developed, techniques have been more diversified. From as aspect of prosthodontic practice, both esthetic and functional requirements are emphasized for coronal restoration and consequently, these should be considered in the routine procedure. In fabrication of coronal restorations, metal, porcelain and resin are commonly used, and there exists the various disadvantages for metal cast method due to complicated processes by using different dental materials. Therefore, an electroforming apparatus was developed by us to replace the conventional procedure by a cathode rotary system. It was applied for coronal restorations to allow an electroforming directly on a working model. An experiment was successfully conducted to apply for a veneer crown on abutment tooth of upper central incisor on plaster model. The results were obtained as follows, 1. It was become possible to construct a metal framework by the electroforming. 2. Metal framework can be constructed on the same working model without a duplication of it. 3. The combined system for cathode rotation and liquid circulation could shorten the electroposition time, and allows a high current density extending to 50 A/dm2.

  2. Melanoma do aparelho ungueal Nail apparatus melanoma

    Directory of Open Access Journals (Sweden)

    Ignez Regina dos Santos Muri Mendonça

    2004-10-01

    Full Text Available O melanoma do aparelho ungueal é apresentação relativamente rara dessa neoplasia, muitas vezes diagnosticada como nevo juncional, hematoma subungueal ou mesmo onicomicose. Esse fato leva a um atraso no diagnóstico e, conseqüentemente, na instituição da terapêutica específica, contribuindo para agravar o prognóstico de uma doença que por si só já é muito agressiva. Os autores relatam um caso de melanoma no primeiro quirodáctilo esquerdo de uma paciente negra com evolução de um ano, ressaltando a importância de avaliar certos critérios clínicos para obter o diagnóstico em fases mais precoces da doença.Nail apparatus melanoma is a rare presentation of melanoma and may be misdiagnosed as junctional nevus, subungual hematoma or onychomycosis. This fact often leads initially to inappropriate treatment and significant delays in appropriately managing such an aggressive disease. The authors report a case of melanoma on the left thumb of a black patient evolving for a year. Emphasis was placed on the importance of assessing certain clinical characteristics in order to reach an early diagnosis.

  3. Apparatus and method for reconstructing data

    International Nuclear Information System (INIS)

    Pavkovich, J.M.

    1977-01-01

    The apparatus and method for reconstructing data are described. A fan beam of radiation is passed through an object, the beam lying in the same quasi-plane as the object slice to be examined. Radiation not absorbed in the object slice is recorded on oppositely situated detectors aligned with the source of radiation. Relative rotation is provided between the source-detector configuration and the object. Reconstruction means are coupled to the detector means, and may comprise a general purpose computer, a special purpose computer, and control logic for interfacing between said computers and controlling the respective functioning thereof for performing a convolution and back projection based upon non-absorbed radiation detected by said detector means, whereby the reconstruction means converts values of the non-absorbed radiation into values of absorbed radiation at each of an arbitrarily large number of points selected within the object slice. Display means are coupled to the reconstruction means for providing a visual or other display or representation of the quantities of radiation absorbed at the points considered in the object. (Auth.)

  4. Apparatus investigates geological aspects of gas hydrates

    Science.gov (United States)

    Booth, J.S.; Winters, W.J.; Dillon, William P.

    1999-01-01

    The US Geological Survey (USGS), in response to potential geohazards, energy resource potential, and climate issues associated with marine gas hydrates, has developed a laboratory research system that permits hydrate genesis and dissociation under deep-sea conditions, employing user-selected sediment types and pore fluids.The apparatus, GHASTI (gas hydrate and sediment test laboratory instrument), provides a means to link field studies and theory and serves as a tool to improve gas hydrate recognition and assessment, using remote sensing techniques.GHASTLI's use was proven in an exploration well project led by the Geological Survey of Canada and the Japanese National Oil Corp., collaborating with Japan Petroleum Exploration Co. and the USGS. The site was in the Mackenzie Delta region of the Northwest Territories (Mallik 2L-38 drillsite).From tests on natural methane hydrate-bearing sand recovered at about 1,000 m subsurface, the in situ quantity of hydrate was estimated from acoustic properties, and a substantial increase in shear strength due to the presence of the hydrate was measured.1 2GHASTI can mimic a wide range of geologic settings and processes. Initial goals involve improved recognition and mapping of gas hydrate-bearing sediments, understanding factors that control the occurrence and concentration of gas hydrates, knowledge of hydrate's significance to slope failure and foundation problems, and analysis of gas hydrate's potential use as an energy resource.

  5. Methods and apparatus for cooling electronics

    Science.gov (United States)

    Hall, Shawn Anthony; Kopcsay, Gerard Vincent

    2014-12-02

    Methods and apparatus are provided for choosing an energy-efficient coolant temperature for electronics by considering the temperature dependence of the electronics' power dissipation. This dependence is explicitly considered in selecting the coolant temperature T.sub.0 that is sent to the equipment. To minimize power consumption P.sub.Total for the entire system, where P.sub.Total=P.sub.0+P.sub.Cool is the sum of the electronic equipment's power consumption P.sub.0 plus the cooling equipment's power consumption P.sub.Cool, P.sub.Total is obtained experimentally, by measuring P.sub.0 and P.sub.Cool, as a function of three parameters: coolant temperature T.sub.0; weather-related temperature T.sub.3 that affects the performance of free-cooling equipment; and computational state C of the electronic equipment, which affects the temperature dependence of its power consumption. This experiment provides, for each possible combination of T.sub.3 and C, the value T.sub.0* of T.sub.0 that minimizes P.sub.Total. During operation, for any combination of T.sub.3 and C that occurs, the corresponding optimal coolant temperature T.sub.0* is selected, and the cooling equipment is commanded to produce it.

  6. Imaging radionuclide analysis apparatus and method

    International Nuclear Information System (INIS)

    Fleming, R.H.

    1993-01-01

    Imaging neutron activation analysis apparatus is described comprising: a vacuum chamber, means for positioning a sample in said vacuum chamber, means for irradiating the sample with neutrons, means for detecting the time when and the energy of gamma rays emitted from the sample and for establishing from the detected gamma ray energies the presence of certain elements in the sample, means for detecting when delayed beta-electrons are emitted from the sample and for imaging the location on the sample from which such delayed beta-electrons are emitted, means for determining time coincidence between detection of gamma rays by said gamma ray detecting means and detection of electrons by said delayed beta-electron detecting means and means for establishing the location of certain elements on the sample from determined coincidence of detected gamma rays and detected delayed beta-electrons and the established gamma ray energies and the image of the location on the sample from which such delayed beta-electrons are emitted

  7. Neutron generator tube ion source control apparatus

    International Nuclear Information System (INIS)

    Bridges, J.R.

    1982-01-01

    A pulsed neutron well logging system includes a neutron generator tube of the deuterium-tritium accelerator type and an ion source control apparatus providing extremely sharply time-defined neutron pulses. A low voltage control pulse supplied to an input by timing circuits turns a power FET on via a buffer-driver whereby a 2000 volt pulse is produced in the secondary of a pulse transformer and applied to the ion source of the tube. A rapid fall in this ion source control pulse is ensured by a quenching circuit wherein a one-shot responds to the falling edge of the control pulse and produces a 3 microsecond delay to compensate for the propagation delay. A second one-shot is triggered by the falling edge of the output of the first one-shot and gives an 8 microsecond pulse to turn on the power FET which, via an isolation transformer turns on a series-connected transistor to ground the secondary of the pulse transformer and the ion source. (author)

  8. Experiences with decontaminating tritium-handling apparatus

    International Nuclear Information System (INIS)

    Maienschein, J.L.; Garcia, F.; Garza, R.G.; Kanna, R.L.; Mayhugh, S.R.; Taylor, D.T.

    1991-07-01

    Tritium-handling apparatus has been decontaminated as part of the shutdown of the LLNL Tritium Facility. Two stainless-steel gloveboxes that had been used to process lithium deuteride-tritide (LiDT) salt were decontaminated using the Portable Cleanup System so that they could be flushed with room air through the facility ventilation system. Further surface decontamination was performed by scrubbing the interior with paper towels and ethyl alcohol or Swish trademark. The surface contamination, as shown by swipe surveys, was reduced from 4x10 4 --10 6 disintegrations per minute (dpm)/cm 2 to 2x10 2 --4x10 4 dpm/cm 2 . Details on the decontamination operation are provided. A series of metal (palladium and vanadium) hydride storage beds have been drained of tritium and flushed with deuterium in order to remove as much tritium as possible. The bed draining and flushing procedure is described, and a calculational method is presented which allows estimation of the tritium remaining in a bed after it has been drained and flushed. Data on specific bed draining and flushing are given

  9. Power operated contact apparatus for superconductive circuit

    Energy Technology Data Exchange (ETDEWEB)

    Woods, D.C.; Efferson, K.R.

    1989-10-10

    This patent describes a power operated contact apparatus for extending and retracting one or more electrical leads into and out of a cryostat for making and breaking, at a cryogenic temperature, electrical contact with a superconductive circuit. It comprises at least one rigid elongated lead for extending into a cold space of the cryostat which is at or near a cryogenic temperature. The lead having an inner end and a outer end; a connector fixed at the inner end of the lead for making electrical contact in the cold space with a connector of the superconductive circuit; guide means journaling the lead for allowing the lead to move axially relative to the guide means and sealing against the lead; a foundation for sealed attachment to the cryostat and to the guide means so that the connector on the inner end of the lead is extendable into making electrical contact with the connector of the superconductive circuit in the cold space; power operated means mounted on the foundation and fixed to the outer end of the lead for extending and retracting the lead to and from making electrical contact with the superconductive circuit in the cold space; and means for de-icing the exterior of the leads and guide means when the leads are connected to the superconducting circuit.

  10. Detached collimator apparatus for radiation therapy

    International Nuclear Information System (INIS)

    Jones, D.

    1989-01-01

    This patent describes a separated collimator and alignment apparatus for use with linear electron accelerators having a beam output structure supported by a gantry and an associated patient couch movable in three-dimensional space relative to the gantry. It comprises: an aperture structure defining an orifice for passage of an electron beam therethrough. The aperture structure being releasably carried by an accelerator collimator tube and the orifice being similarly configured to and not larger than an aperture defined in a patient collimator tube; the patient collimator tube defining a first medial channel for passage of a coherent electron beam and defining a planar input end facing the aperture structure and an exit end distal therefrom; an annular positioning ring defining a second medial channel to fit about the periphery of the patient collimator tube. The positioning ring defining first means for attachment to a positioning jig mechanism and second means for releasable and adjustable positional maintenance upon the patient collimator tube. The positioning jig mechanism having at least two rigid rods joined for articulating motion with the first means at a first end to fastenably interconnect with the positioning ring and the second means at a second end for support on a structure external of an electron accelerator to be serviced; and an elongate alignment rod carried by a base support disk releasably positionable in a first inner accelerator facing end of the patient collimator tube to aid axial alignment of the alignment rod with the patient collimator tube

  11. Sub-micron particle sampler apparatus

    Science.gov (United States)

    Gay, Don D.; McMillan, William G.

    1987-01-01

    Apparatus and method steps for collecting sub-micron sized particles include a collection chamber and cryogenic cooling. The cooling is accomplished by coil tubing carrying nitrogen in liquid form, with the liquid nitrogen changing to the gas phase before exiting from the collection chamber in the tubing. Standard filters are used to filter out particles of diameter greater than or equal to 0.3 microns; however the present invention is used to trap particles of less than 0.3 micron in diameter. A blower draws air to said collection chamber through a filter which filters particles with diameters greater than or equal to 0.3 micron. The air is then cryogenically cooled so that moisture and sub-micron sized particles in the air condense into ice on the coil. The coil is then heated so that the ice melts, and the liquid is then drawn off and passed through a Buchner funnel where the liquid is passed through a Nuclepore membrane. A vacuum draws the liquid through the Nuclepore membrane, with the Nuclepore membrane trapping sub-micron sized particles therein. The Nuclepore membrane is then covered on its top and bottom surfaces with sheets of Mylar.RTM. and the assembly is then crushed into a pellet. This effectively traps the sub-micron sized particles for later analysis.

  12. Porous electrode apparatus for electrodeposition of detailed metal structures or microelectronic interconnections

    Science.gov (United States)

    Griffiths, Stewart K.; Nilson, Robert H.; Hruby, Jill M.

    2002-01-01

    An apparatus and procedure for performing microfabrication of detailed metal structures by electroforming metal deposits within small cavities. Two primary areas of application are: the LIGA process which manufactures complex three-dimensional metal parts and the damascene process used for electroplating line and via interconnections of microelectronic devices. A porous electrode held in contact or in close proximity with a plating substrate or mold top to ensure one-dimensional and uniform current flow into all mold cavities is used. Electrolyte is pumped over the exposed surface of the porous electrode to ensure uniform ion concentrations at this external surface. The porous electrode prevents electrolyte circulation within individual mold cavities, avoiding preferential enhancement of ion transport in cavities having favorable geometries. Both current flow and ion transport are one-dimensional and identical in all mold cavities, so all metal deposits grow at the same rate eliminating nonuniformities of the prior art.

  13. Simple homemade apparatus for harvesting uncultured magnetotactic microorganisms

    Directory of Open Access Journals (Sweden)

    Lins Ulysses

    2003-01-01

    Full Text Available A simple apparatus for harvesting uncultured magnetotactic microorganisms is described. This apparatus consists of a glass container with two openings. A large opening on the topside is used to introduce the sediment and water. The sediment and water are previously stored in loosely capped bottles previously tested for the presence of magnetotactic bacteria. The apparatus is exposed to a properly aligned magnetic field of a homemade coil and the bacteria are removed through the capillary end of the second opening of the container. Harvested bacteria can then be used to ultrastrucutral studies using electron spectroscopic imaging. Large numbers of magnetotactic bacteria consisting of cocci and rod-shaped cells were efficiently collected from different environments. This apparatus is useful for microbiological studies on uncultured magnetotactic bacteria, especially in molecular approaches for phylogenetic investigations that give information on the natural diversity of microbial communities.

  14. Optical trapping apparatus, methods and applications using photonic crystal resonators

    Science.gov (United States)

    Erickson, David; Chen, Yih-Fan

    2015-06-16

    A plurality of photonic crystal resonator optical trapping apparatuses and a plurality optical trapping methods using the plurality of photonic crystal resonator optical trapping apparatuses include located and formed over a substrate a photonic waveguide that is coupled (i.e., either separately coupled or integrally coupled) with a photonic crystal resonator. In a particular embodiment, the photonic waveguide and the photonic crystal resonator comprise a monocrystalline silicon (or other) photonic material absent any chemical functionalization. In another particular embodiment, the photonic waveguide and the photonic crystal resonator comprise a silicon nitride material which when actuating the photonic crystal resonator optical trapping apparatus with a 1064 nanometer resonant photonic radiation wavelength (or other resonant photonic radiation wavelength in a range from about 700 to about 1200 nanometers) provides no appreciable heating of an aqueous sample fluid that is analyzed by the photonic crystal resonator optical trapping apparatus.

  15. Apparatus for handling micron size range particulate material

    Science.gov (United States)

    Friichtenicht, J. F.; Roy, N. L. (Inventor)

    1968-01-01

    An apparatus for handling, transporting, or size classifying comminuted material was described in detail. Electrostatic acceleration techniques for classifying particles as to size in the particle range from 0.1 to about 100 microns diameter were employed.

  16. 21 CFR 884.5900 - Therapeutic vaginal douche apparatus.

    Science.gov (United States)

    2010-04-01

    ... douche solutions. The apparatus is intended and labeled for use in the treatment of medical conditions... solution, the patient uses the device to direct a stream of solution into the vaginal cavity. (b...

  17. Automated preference testing apparatus for rating palatability of foods.

    Science.gov (United States)

    Thompson, R D; Grant, C V

    1971-03-01

    An electronic preference testing apparatus is described for measuring taste preference of rodents and other small animals with solid or liquid foods. The apparatus is designed on the principle of the two-choice, preference technique. It operates photoelectrically with a sequence of presentations so that whenever a subject eats from a compartmentalized food tray, a standard and a test food are each briefly sampled alone before both foods are presented together (in alternate positions) for preference determination. Preferences are automatically recorded on digital counters. The apparatus is built in two modules (a preference tester and the master control) connected by multiconductor cable. The modular design provides portability and isolation of the animals from the major noise-producing components. Diagrams of the apparatus are given, and test results from a trial that evaluated positional bias and a sucrose-concentration preference experiment are presented to demonstrate its application in research.

  18. Automated preference testing apparatus for rating palatability of foods1

    Science.gov (United States)

    Thompson, R. D.; Grant, C. V.

    1971-01-01

    An electronic preference testing apparatus is described for measuring taste preference of rodents and other small animals with solid or liquid foods. The apparatus is designed on the principle of the two-choice, preference technique. It operates photoelectrically with a sequence of presentations so that whenever a subject eats from a compartmentalized food tray, a standard and a test food are each briefly sampled alone before both foods are presented together (in alternate positions) for preference determination. Preferences are automatically recorded on digital counters. The apparatus is built in two modules (a preference tester and the master control) connected by multiconductor cable. The modular design provides portability and isolation of the animals from the major noise-producing components. Diagrams of the apparatus are given, and test results from a trial that evaluated positional bias and a sucrose-concentration preference experiment are presented to demonstrate its application in research. PMID:5550602

  19. Apparatus facilitates pressure-testing of metal tubing

    Science.gov (United States)

    Gyorgak, C. A.

    1965-01-01

    Burst-testing of refractory metal tubing is conducted in an apparatus in which tubular specimans are firmly gripped and test pressures and temperatures are applied. Porosity, flaw, and fatigue-stress rupture are also tested.

  20. Apparatuses, Systems and Methods for Cleaning Photovoltaic Devices

    KAUST Repository

    Eitelhuber, Georg

    2013-02-14

    Embodiments of solar panel cleaning apparatuses, solar panel cleaning systems, and solar panel cleaning methods are disclosed. In certain embodiments, the disclosed solar panel cleaning apparatuses, systems and methods do may not require any water or other cleaning liquids in the whole cleaning process, which makes them prominent well suited in for water-deficit environments such as deserts. In one embodiment, the solar panel cleaning apparatus comprises one or more rotatable brushes each having a rotational axis and a drive configured to move each of the one or more rotatable brushes in a direction that is not perpendicular to the rotational axis. The solar panel cleaning apparatus is may be configured such that the angle of the rotational axis of at least one of the one or more rotatable brushes is adjustable relative to the direction of travel.

  1. Training Studies with Compressed Air Breathing Apparatus – Methodology, Exercises

    Directory of Open Access Journals (Sweden)

    Buks Roberts

    2015-11-01

    Full Text Available The current article describes topics ranging from the respiratory physiology and the structure of compressed air breathing apparatus to the performance of practical training exercises in an unbreathable environment (hereinafter referred to as UE.

  2. The Importance of Selecting Suitable Components and Apparatus in ...

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 15; Issue 1. The Importance of Selecting Suitable Components and Apparatus in Physics Laboratories. Vijay H Raybagkar. Classroom Volume 15 Issue 1 January 2010 pp 76-82 ...

  3. Artificial softness sensing - an automatic apparatus for measuring viscoelasticity

    Science.gov (United States)

    Kato, I.; Kudo, Y.; Ichimaru, K.

    1975-01-01

    Synthetic polymer models of several degrees of softness were subjected to standard creep tests to determine their viscoelastic characteristics. The automatic measuring apparatus and the theory of measurement used in modeling the human recognition of the softness factor are described.

  4. Remote Blood Pressure Waveform Sensing Method and Apparatus

    National Research Council Canada - National Science Library

    Antonelli, Lynn T

    2008-01-01

    The invention as disclosed is a non-contact method and apparatus for continuously monitoring a physiological event in a human or animal, such as blood pressure, which involves utilizing a laser-based...

  5. CW frequency doubling of 1029 nm radiation using single pass bulk and waveguide PPLN crystals

    Czech Academy of Sciences Publication Activity Database

    Chiodo, N.; Du Burck, F.; Hrabina, Jan; Candela, Y.; Wallerand, J. P.; Acef, O.

    2013-01-01

    Roč. 311, 15 January (2013), s. 239-244 ISSN 0030-4018 R&D Projects: GA ČR GPP102/11/P820 Institutional support: RVO:68081731 Keywords : IR laser * second harmonic generation * waveguide and bulk crystals * periodically poled lithium niobate * 1029 nm wavelength Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.542, year: 2013

  6. Single-pass beam measurements for the verification of the LHC magnetic model

    CERN Document Server

    Calaga, R; Redaelli, S; Sun, Y; Tomas, R; Venturini-Delsolaro, W; Zimmermann, F

    2010-01-01

    During the 2009 LHC injection tests, the polarities and effects of specific quadrupole and higher-order magnetic circuits were investigated. A set of magnet circuits had been selected for detailed investigation based on a number of criteria. On or off-momentum difference trajectories launched via appropriate orbit correctors for varying strength settings of the magnet circuits under study - e.g. main, trim and skew quadrupoles; sextupole families and spool piece correctors; skew sextupoles, octupoles - were compared with predictions from various optics models. These comparisons allowed confirming or updating the relative polarity conventions used in the optics model and the accelerator control system, as well as verifying the correct powering and assignment of magnet families. Results from measurements in several LHC sectors are presented.

  7. Safety Evaluation for Packaging for the N Reactor/single pass reactor fuel characterization shipments

    International Nuclear Information System (INIS)

    Stevens, P.F.

    1994-01-01

    The purpose of this Safety Evaluation for Packaging (SEP) is to authorize the ChemNuclear CNS 1-13G packaging to ship samples of irradiated fuel elements from the 100 K East and 100 K West basins to the Postirradiation Testing Laboratory (PTL) in support of the spent nuclear fuel characterization effort. It also authorizes the return of the fuel element samples to the 100 K East facility using the same packaging. The CNS 1-13G cask has been-chosen to transport the fuel because it has a Certificate of Compliance (CoC) issued by the US Nuclear Regulatory Commission (NRC) for transporting irradiated oxide and metal fuel in commerce. It is capable of being loaded and offloaded underwater and may be shipped with water in the payload compartment

  8. A Novel Single Pass Authenticated Encryption Stream Cipher for Software Defined Radios

    DEFF Research Database (Denmark)

    Khajuria, Samant

    2012-01-01

    high throughput and low overhead for SDRs. The thesis is divided into two research topics. One topic is the design of a 1-pass authenticated encryption scheme that can accomplish both message secrecy and authenticity in a single cryptographic primitive. The other topic is the implementation......With the rapid growth of new wireless communication standards, a solution that is able to provide a seamless shift between existing wireless protocols and high flexibility as well as capacity is crucial. Software Defined Radio (SDR) technology offers this flexibility. It gives the possibility...

  9. Single-Pass Catalytic Conversion of Syngas into Olefins via Methanol.

    Science.gov (United States)

    Olsbye, Unni

    2016-06-20

    All together now: Combination in a single reactor of the catalysts for converting syngas into methanol and methanol into olefins was recently reported by Cheng et al. This approach considerably simplifies the catalytic conversion of natural gas. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Non-linear optics for the final focus of the single-pass-collider

    International Nuclear Information System (INIS)

    Brown, K.L.; Spencer, J.E.

    1981-02-01

    The purpose of the final focus system (FFS) is to demagnify the beam envelope in the Collider arc lattice to a size suitable for beam collisions at the interaction region. The final spot size is determined by the beam emittance, the beta function β* at the IR, the momentum spread in the beam, and the quality of the FFS optics. In particular, if the focusing system is not chromatically corrected, the momentum dispersion in the beam can lead to a substantial degradation in the quality of the final focus. The objective is to design a FFS for 50 GeV/c within approx. 100 meters having an IR spot size sigma/sub xy/ of approximately 2 μm for a beam emittance of epsilon = 3 x 10 -10 m-rad and a momentum spread of delta = +-0.5%. This requires a β/sub x,y/ equal to or less than 1 cm. This report considers the problems encountered in the design of a final focus system that will reliably provide the desired beam size for collisions

  11. 46 CFR 78.47-27 - Self-contained breathing apparatus.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Self-contained breathing apparatus. 78.47-27 Section 78... Markings for Fire and Emergency Equipment, Etc. § 78.47-27 Self-contained breathing apparatus. Lockers or spaces containing self-contained breathing apparatus shall be marked “SELF-CONTAINED BREATHING APPARATUS...

  12. Development of an experimental apparatus for boiling analysis

    International Nuclear Information System (INIS)

    Castro, A.J.A. de.

    1984-04-01

    The nucleate boiling is the most interesting boiling regime for practical appliccations, including nuclear reactor engineering. such regime is characterized by very high heat transfer rates with only small surface superheating. An experimental apparatus is developed for studying parameters which affect nucleate boiling. The following parameters are analysed: pressure, fluid velocity and the fluid temperature at the test section entrance. The performance of experimental apparatus is analysed by results and by problems raised by the oeration of setup. (Author) [pt

  13. Combustion engine variable compression ratio apparatus and method

    Science.gov (United States)

    Lawrence,; Keith, E [Peoria, IL; Strawbridge, Bryan E [Dunlap, IL; Dutart, Charles H [Washington, IL

    2006-06-06

    An apparatus and method for varying a compression ratio of an engine having a block and a head mounted thereto. The apparatus and method includes a cylinder having a block portion and a head portion, a piston linearly movable in the block portion of the cylinder, a cylinder plug linearly movable in the head portion of the cylinder, and a valve located in the cylinder plug and operable to provide controlled fluid communication with the block portion of the cylinder.

  14. Apparatus, System, and Method for Forward Osmosis in Water Reuse

    KAUST Repository

    Yangali-Quintanilla, Victor

    2013-01-03

    An apparatus, system, and method for desalinating water is presented. The invention relates to recovery of water from impaired water sources by using FO and seawater as draw solution (DS). The seawater becomes diluted over time and can be easily desalinated at very low pressures. Thus, a device consumes less energy when recovering water. The apparatus, system and method comprise an immersed forward osmosis cell.

  15. Apparatus for laser slowing and cooling of molecules

    Science.gov (United States)

    2016-10-09

    SECURITY CLASSIFICATION OF: This is the final report for our DURIP grant entitled "Apparatus for Laser Slowing and cooling of Molecules". We have... cooling of a new molecular species, TlF. We have also successfully acquired and assembled the parts for a custom laser system, which produces long...Distribution Unlimited UU UU UU UU 09-10-2016 1-Sep-2012 31-Aug-2014 Final Report: Apparatus for laser slowing and cooling of molecules The views

  16. Method and apparatus for controlling gas evolution from chemical reactions

    Science.gov (United States)

    Skorpik, James R.; Dodson, Michael G.

    1999-01-01

    The present invention is directed toward monitoring a thermally driven gas evolving chemical reaction with an acoustic apparatus. Signals from the acoustic apparatus are used to control a heater to prevent a run-away condition. A digestion module in combination with a robotic arm further automate physical handling of sample material reaction vessels. The invention is especially useful for carrying out sample procedures defined in EPA Methods SW-846.

  17. Apparatus and Method for Communication over Power Lines

    Science.gov (United States)

    Krasowski, Michael J. (Inventor); Prokop, Norman F. (Inventor); Greer, III, Lawrence C. (Inventor); Nappier, Jennifer M. (Inventor)

    2017-01-01

    An apparatus and method are provided for communicating over power lines. The apparatus includes a coupling modem that is situated between a power line and a device. The coupling modem is configured to demodulate a signal received from the power line into a sine signal and a cosine signal. The coupling modem is also configured to modulate a communicated bit stream received from the device into a transmitted signal in order to impose the transmitted signal onto the power line.

  18. Apparatus for defining a beam of ionizing radiation

    International Nuclear Information System (INIS)

    1981-01-01

    Novel apparatus for defining a beam of ionizing radiation in the course of radiotherapy treatment is described in detail. The particular case of electron irradiation of the patient is discussed. The apparatus consists of an adjustable primary collimator which produces a cone of ionizing radiation, an attachment holder adjacent to the primary collimator and a detachable radiation applicator. The attachment holder may be removed when irradiation with X-rays is desired. (U.K.)

  19. Rescue apparatus for a high working oil derrick

    Energy Technology Data Exchange (ETDEWEB)

    Prokopov, O.P.; Yagudin, S.Z.

    1980-05-18

    In order to improve reliability of the rescue apparatus a device for lowering a basket is made in the form of a collapsible forked support installed in the vertical plane inclined away from the tower. Its lower ends are attached by hinges to the base of the derrick. The upper end is connected to the derrick by means of a fastener. The apparatus has brakes with shock straps for receiving forked support.

  20. Method and apparatus for vibrating a substrate during material formation

    Science.gov (United States)

    Bailey, Jeffrey A [Richland, WA; Roger, Johnson N [Richland, WA; John, Munley T [Benton City, WA; Walter, Park R [Benton City, WA

    2008-10-21

    A method and apparatus for affecting the properties of a material include vibrating the material during its formation (i.e., "surface sifting"). The method includes the steps of providing a material formation device and applying a plurality of vibrations to the material during formation, which vibrations are oscillations having dissimilar, non-harmonic frequencies and at least two different directions. The apparatus includes a plurality of vibration sources that impart vibrations to the material.