WorldWideScience

Sample records for single-monochrometer spectrophotometer manufactured

  1. Optical fiber spectrophotometer

    International Nuclear Information System (INIS)

    Zhuang Weixin; Tian Guocheng; Ye Guoan; Zhou Zhihong; Cheng Weiwei; Huang Lifeng; Liu Suying; Tang Yanji; Hu Jingxin; Zhao Yonggang

    1998-12-01

    A method called 'Two Arm's Photo out and Electricity Send-back' is introduced. UV-365 UV/VIS/NIR spectrophotometer has been reequipped by this way with 5 meters long optical fiber. Another method called 'One Arm's Photo out and Photo Send-back' is also introduced. λ 19 UV/VIS/NIR spectrophotometer has been reequipped by this way with 10 meters long optical fiber. Optical fiber spectrophotometer can work as its main set. So it is particularly applicable to radio activity work

  2. FAST SCANNING HADAMARD SPECTROPHOTOMETER

    OpenAIRE

    POPPI, RJ; VAZQUEZ, PAM; PASQUINI, C

    1992-01-01

    A simple, low-cost, multiplexed Hadamard-type spectrophotometer based on a spinning disk containing 63 separated masks has been constructed to obtain spectral data in time intervals down to 50 ms. Each mask contains 63 resolution elements. Optical localization and identification of the masks were implemented in the disk to avoid misalignment problems. The control of the spectrophotometer and data acquisition was made by using a dedicated single-board microcomputer based on an 8085 CPU. The si...

  3. Multichannel scanning spectrophotometer

    International Nuclear Information System (INIS)

    Lagutin, A.F.

    1979-01-01

    A spectrophotometer designed in the Crimea astrophysical observatory is described. The spectrophotometer is intended for the installation at the telescope to measure energy distribution in the star spectra in the 3100-8550 A range. The device is made according to the scheme with a fixed diffraction lattice. The choice of the optical kinematic scheme is explained. The main design elements are shown. Some singularities of the scanning drive kinematics are considered. The device performance is given

  4. Dobson ozone spectrophotometer modification.

    Science.gov (United States)

    Komhyr, W. D.; Grass, R. D.

    1972-01-01

    Description of a modified version of the Dobson ozone spectrophotometer in which several outdated electronic design features have been replaced by circuitry embodying more modern design concepts. The resulting improvement in performance characteristics has been obtained without changing the principle of operation of the original instrument.

  5. Development of Raman spectrophotometer

    International Nuclear Information System (INIS)

    Adam, A.I.

    2008-05-01

    In this work, the Raman spectrophotometer HG.2S Jobin Yvon rebuilt and developed, the Raman setup provided as a gift for Neelian University from Amsterdam University. The main parts, which were replaced, include monochromator, an air-cooled photomultiplier tube RCA IP 28, log amplifier, hand scanning lab VIEW card for computer interfacing. The components assembled and the whole device was tested successfully. The developed setup was checked using some standard solutions, which showed perfect consistency with literature in the references and published papers. Solutions included hexane, cyclohexane, carbon tetrachloride, benzene and sodium sulfate.(Author)

  6. Optoelectronics instrumentation of a spectrophotometer

    International Nuclear Information System (INIS)

    Lopez, A.; Camas, J.; Rios, C.; Lopez, F.; Anzueto, G.; Castannon, J.; Dominguez, J.

    2016-01-01

    Today, it is necessary to characterize materials to generate knowledge and propose new technology in the development of optical sensors. However, the acquisition of spectrophotometers is not easy for the researchers that not have an economic resource. So, in this paper the design of a spectrophotometer is presented using optical technology such as light source, light and electron scattering commercially available in Mexico, and whose construction is cheap and easy to build. (Author)

  7. [A micro-silicon multi-slit spectrophotometer based on MEMS technology].

    Science.gov (United States)

    Hao, Peng; Wu, Yi-Hui; Zhang, Ping; Liu, Yong-Shun; Zhang, Ke; Li, Hai-Wen

    2009-06-01

    A new mini-spectrophotometer was developed by adopting micro-silicon slit and pixel segmentation technology, and this spectrophotometer used photoelectron diode array as the detector by the back-dividing-light way. At first, the effect of the spectral bandwidth on the tested absorbance linear correlation was analyzed. A theory for the design of spectrophotometer's slit was brought forward after discussing the relationships between spectrophotometer spectrum band width and pre-and post-slits width. Then, the integrative micro-silicon-slit, which features small volume, high precision, and thin thickness, was manufactured based on the MEMS technology. Finally, a test was carried on linear absorbance solution by this spectrophotometer. The final result showed that the correlation coefficients were larger than 0.999, which means that the new mini-spectrophotometer with micro-silicon slit pixel segmentation has an obvious linear correlation.

  8. Spectrophotometer-Based Color Measurements

    Science.gov (United States)

    2017-10-24

    ABOVE ADDRESS. 1. REPORT DATE (DD-MM-YYYY) October 2017 2. REPORT TYPE Final 3. DATES COVERED (From – To) March 2016 to October 2016 4. TITLE AND...evaluated using nominal values for L*a*b* (color space) from international paint suppliers. The results demonstrate the value of using a spectrophotometer...for color measurements. The experimental L*a*b* values for a large number of colors from the federal color standard listing are reported. 15

  9. Modernization of Atomic Absorption Spectrophotometer

    International Nuclear Information System (INIS)

    Tasic, Visa; Milivojevic, Dragan; Karabasevic, Dejan

    2003-01-01

    In Copper Institute in Bor, connection has been made between absorption spectrophotometer and standard PC with the aim to make its operation more reliable and comfortable. Applied solution includes both software and hardware components. An I/O interface module has been installed in PC [1]. Software component consists of programs for measuring and interpretation of results. Paper presents details of this job realization.(Author)

  10. Shutter mechanism for spacecraft spectrophotometer

    Science.gov (United States)

    Weilbach, A.

    1972-01-01

    A shutter mechanism is described for the backscatter ultraviolet spectrophotometer experiment on the Nimbus D satellite. The purpose of the experiment is to determine spatial distribution of atmospheric ozone from measurements of ultraviolet radiation backscattered by the earth's atmosphere. The system consists of two independent, rotary cylinder shutters, controlled by a dual star Geneva mechanism, and driven by a single stepper motor. A single driver controls a combination of two independently driven Geneva stars. Design considerations involved the use of low friction, nonmetallic materials.

  11. Method and apparatus for calibrating spectrophotometers

    NARCIS (Netherlands)

    Schreutelkamp, F.H.

    2003-01-01

    The present invention relates to a method of calibrating spectrophotometers by placing one or more filters in the light path of the spectrophotometer and measuring the amount of radiation by means of a detector. The present invention furthermore relates to an apparatus to be used with such a method.

  12. A Low-Cost Quantitative Absorption Spectrophotometer

    Science.gov (United States)

    Albert, Daniel R.; Todt, Michael A.; Davis, H. Floyd

    2012-01-01

    In an effort to make absorption spectrophotometry available to high school chemistry and physics classes, we have designed an inexpensive visible light absorption spectrophotometer. The spectrophotometer was constructed using LEGO blocks, a light emitting diode, optical elements (including a lens), a slide-mounted diffraction grating, and a…

  13. Evaluation of accuracy of shade selection using two spectrophotometer systems: Vita Easyshade and Degudent Shadepilot.

    Science.gov (United States)

    Kalantari, Mohammad Hassan; Ghoraishian, Seyed Ahmad; Mohaghegh, Mina

    2017-01-01

    The aim of this in vitro study was to evaluate the accuracy of shade matching using two spectrophotometric devices. Thirteen patients who require a full coverage restoration for one of their maxillary central incisors were selected while the adjacent central incisor was intact. 3 same frameworks were constructed for each tooth using computer-aided design and computer-aided manufacturing technology. Shade matching was performed using Vita Easyshade spectrophotometer, Shadepilot spectrophotometer, and Vitapan classical shade guide for the first, second, and third crown subsequently. After application, firing, and glazing of the porcelain, the color was evaluated and scored by five inspectors. Both spectrophotometric systems showed significantly better results than visual method ( P spectrophotometers ( P Spectrophotometers are a good substitute for visual color selection methods.

  14. Data comparison between two dental spectrophotometers

    NARCIS (Netherlands)

    Khashayar, G.; Dozic, A.; Kleverlaan, C.J.; Feilzer, A.J.

    2012-01-01

    Objectives: The objective of this study was to clinically test whether the data from two different spectrophotometers, based on spot and surface measurements, can be compared. Methods: Under standardized clinical conditions two devices (Vita Easyshade and SpectroShade-Micro) were used to record the

  15. The Fuge Tube Diode Array Spectrophotometer

    Science.gov (United States)

    Arneson, B. T.; Long, S. R.; Stewart, K. K.; Lagowski, J. J.

    2008-01-01

    We present the details for adapting a diode array UV-vis spectrophotometer to incorporate the use of polypropylene microcentrifuge tubes--fuge tubes--as cuvettes. Optical data are presented validating that the polyethylene fuge tubes are equivalent to the standard square cross section polystyrene or glass cuvettes generally used in…

  16. Enzyme Activity Experiments Using a Simple Spectrophotometer

    Science.gov (United States)

    Hurlbut, Jeffrey A.; And Others

    1977-01-01

    Experimental procedures for studying enzyme activity using a Spectronic 20 spectrophotometer are described. The experiments demonstrate the effect of pH, temperature, and inhibitors on enzyme activity and allow the determination of Km, Vmax, and Kcat. These procedures are designed for teaching large lower-level biochemistry classes. (MR)

  17. Brewer spectrophotometer measurements in the Canadian Arctic

    Science.gov (United States)

    Kerr, J. B.; Evans, W. F. J.

    1988-01-01

    In the winters of 1987 and 1988 measurements were conducted with the Brewer Spectrophotometer at Alert (82.5 N) and Resolute (74.5 N). The measurements were conducted as part of our Canadian Program to search for an Arctic Ozone Hole (CANOZE). Ozone measurements were conducted in the months of December, January and February using the moon as a light source. The total ozone measurements will be compared with ozonesonde profiles, from ECC sondes, flown once per week from Alert and Resolute. A modified Brewer Spectrophotometer was used in a special study to search for chlorine dioxide at Alert in March 1987. Ground based observations at Saskatoon in February and at Alert in March 1987 failed to detect any measureable chlorine dioxide. Interference from another absorbing gas, which we speculate may be nitrous acid, prevented the measurements at the low levels of chlorine dioxide detected in the Southern Hemisphere by Solomon et al.

  18. The EUV spectrophotometer on Atmosphere Explorer.

    Science.gov (United States)

    Hinteregger, H. E.; Bedo, D. E.; Manson, J. E.

    1973-01-01

    An extreme ultraviolet (EUV) spectrophotometer for measurements of solar radiation at wavelengths ranging from 140 to 1850 A will be included in the payload of each of the three Atmosphere-Explorer (AE) missions, AE-C, -D, and -E. The instrument consists of 24 grating monochromators, 12 of which can be telecommanded either to execute 128-step scans each covering a relatively small section of the total spectrophotometer wavelength range or to maintain fixed (command-selected) wavelength positions. The remaining 12 nonscan monochromators operate at permanently fixed wavelengths and view only a small fraction of the solar disk except for one viewing the whole sun in H Lyman alpha. Ten of the 12 scan-capable monochromators also view the entire solar disk since their primary function is to measure the total fluxes independent of the distribution of sources across the solar disk.

  19. [New application of atomic absorption spectrophotometer in testing technology].

    Science.gov (United States)

    Zhao, Z; Chen, H

    1998-02-01

    A simple and satisfactory method is developed for the new application of AAS. We can just rely on atomic absorption spectrophotometer without flame on place of UV-Visible spectrophotometer. The operation is very simple, and it can raise the efficiency of AAS. This experiment offers a possibility to find new applications of atomic absorption spectrophotometer.

  20. A Simple Spectrophotometer Using Common Materials and a Digital Camera

    Science.gov (United States)

    Widiatmoko, Eko; Widayani; Budiman, Maman; Abdullah, Mikrajuddin; Khairurrijal

    2011-01-01

    A simple spectrophotometer was designed using cardboard, a DVD, a pocket digital camera, a tripod and a computer. The DVD was used as a diffraction grating and the camera as a light sensor. The spectrophotometer was calibrated using a reference light prior to use. The spectrophotometer was capable of measuring optical wavelengths with a…

  1. A mini-rapid-scan-spectrophotometer.

    Science.gov (United States)

    Schmidt, Werner

    2004-02-27

    The mini-rapid-scan-spectrophotometer (Mini-RSS) is a scanning single-beam spectrophotometer that has been patented. It is based on a minimum of reflections and involves exclusively mirrors as beam-deflecting components. This way stray light is minimized, which results in an excellent light-throughput, high dynamics, low cost, compactness and rigidity. The Mini-RSS has been designed as a multi-purpose instrument that allows absorption, transmission, reflection, fluorescence and luminescence measurements in a single-beam mode. Its spectral range extends from the UV and visible spectrum to the IR. This provides for the possibility to measure even optically unfavorable, highly turbid or scattering samples that would be otherwise inaccessible to investigations with commercial spectrophotometers. A miniaturized and very sensitive photomultiplier-module (PM) of high dynamics allows in the visible spectral range absorbance measurements that cover up to four OD units. The Mini-RSS is capable of scanning up to 100 spectra per second with a resolution of 12 bit and 500 points. The linear dispersion is currently 5 nm and the stray light level <0.01%.

  2. [Assessment of tooth bleaching efficacy with spectrophotometer].

    Science.gov (United States)

    Zhu, Wenhao; Liu, Chang; Pan, Jie

    2014-06-01

    To analyze the changes in CIE L*, a*, and b* at cervical, body, and incisal sites after tooth bleaching by using a spectrophotometer. Sixty-seven intact and healthy maxillary central incisors were in-vestigated. These incisors were darker than A3 according to the Vita Classical shade guide. The CIE tooth shade parameters L*, a*, and b* were simultaneously recorded at three tooth areas (cervical, body, and incisal) with a spectrophotometer before and after tooth bleaching (35%H2O2 coordinating with Beyond whitening accelerator irradiating). The shade dif-ferential (DeltaE) was calculated. ANOVA, paired t-test, and Pearson correlation analysis were used for data analysis. The efficacy rates of tooth bleaching were satisfactory, with 86.6%, 86.6%, and 85.1% in the cervical, body, and incisal sites, respectively. The average values of DeltaE were 5.09, 4.44, and 4.40 in the cervical, body, and incisal sites. Tooth bleaching significantly increased L* and significantly decreased a* and b* in all tooth areas (P spectrophotometer could objectively evaluate the whitening effect of tooth bleaching at the different tooth sites. The tooth bleaching system (35%H202 coordinating with Beyond whitening accelerator irradiating) exerts powerful bleaching actions in most of the tooth areas investigated. The order of tooth bleaching effectiveness is cervicalbody>incisal. Yellow coloration is decreased mainly at the cervical site, and brightness was increased mostly at theincisal site. The effectiveness of tooth bleaching increases as the baseline b* value increases.

  3. Results from laboratory and field testing of nitrate measuring spectrophotometers

    Science.gov (United States)

    Snazelle, Teri T.

    2015-01-01

    Five ultraviolet (UV) spectrophotometer nitrate analyzers were evaluated by the U.S. Geological Survey (USGS) Hydrologic Instrumentation Facility (HIF) during a two-phase evaluation. In Phase I, the TriOS ProPs (10-millimeter (mm) path length), Hach NITRATAX plus sc (5-mm path length), Satlantic Submersible UV Nitrate Analyzer (SUNA, 10-mm path length), and S::CAN Spectro::lyser (5-mm path length) were evaluated in the HIF Water-Quality Servicing Laboratory to determine the validity of the manufacturer's technical specifications for accuracy, limit of linearity (LOL), drift, and range of operating temperature. Accuracy specifications were met in the TriOS, Hach, and SUNA. The stock calibration of the S::CAN required two offset adjustments before the analyzer met the manufacturer's accuracy specification. Instrument drift was observed only in the S::CAN and was the result of leaching from the optical path insert seals. All tested models, except for the Hach, met their specified LOL in the laboratory testing. The Hach's range was found to be approximately 18 milligrams nitrogen per liter (mg-N/L) and not the manufacturer-specified 25 mg-N/L. Measurements by all of the tested analyzers showed signs of hysteresis in the operating temperature tests. Only the SUNA measurements demonstrated excessive noise and instability in temperatures above 20 degrees Celsius (°C). The SUNA analyzer was returned to the manufacturer at the completion of the Phase II field deployment evaluation for repair and recalibration, and the performance of the sensor improved significantly.

  4. Last improvements of the DTC 1000 spectrophotometer

    International Nuclear Information System (INIS)

    Blanc, F.

    1988-01-01

    The DTC 1000 spectrophotometer, based on optical fibers and photodiode array was developed for Pu(IV) measurement in fuel reprocessing. The apparatus takes advantage of experience acquired in optical fibers instrumentation and of the study of gamma radiation effects on fibers. This paper give the complete evolution of these last months (memory, hardware, software, background noise). But the principle of the apparatus and examples of results obtained on americium and plutonium on a previous version of the apparatus are recalled. 17 figs., 6 refs [fr

  5. A multi-channel coronal spectrophotometer.

    Science.gov (United States)

    Landman, D. A.; Orrall, F. Q.; Zane, R.

    1973-01-01

    We describe a new multi-channel coronal spectrophotometer system, presently being installed at Mees Solar Observatory, Mount Haleakala, Maui. The apparatus is designed to record and interpret intensities from many sections of the visible and near-visible spectral regions simultaneously, with relatively high spatial and temporal resolution. The detector, a thermoelectrically cooled silicon vidicon camera tube, has its central target area divided into a rectangular array of about 100,000 pixels and is read out in a slow-scan (about 2 sec/frame) mode. Instrument functioning is entirely under PDP 11/45 computer control, and interfacing is via the CAMAC system.

  6. Far-infrared spectrophotometer for astronomical observations

    Science.gov (United States)

    Moseley, H.; Silverberg, R. F.

    1981-01-01

    A liquid-helium-cooled far infrared spectrophotometer was built and used to make low resolution observations of the continua of several kinds of astronomical objects using the Kuiper Airborne Observatory. This instrument fills a gap in both sensitivity to continuum sources and spectral resolution between the broadband photometers with lambda/Delta lambda approximately 1 and spectrometers with lambda/Delta lambda greater than 50. While designed primarily to study planetary nebulae, the instrument permits study of the shape of the continua of many weak sources which cannot easily be observed with high resolution systems.

  7. Data comparison between two dental spectrophotometers.

    Science.gov (United States)

    Khashayar, G; Dozic, A; Kleverlaan, C J; Feilzer, A J

    2012-01-01

    The objective of this study was to clinically test whether the data from two different spectrophotometers, based on spot and surface measurements, can be compared. Under standardized clinical conditions two devices (Vita Easyshade and Spectro Shade-Micro) were used to record the color of three areas (cervical, middle, and incisal) per tooth for three upper maxillary anterior teeth in 102 participants. Each position was measured three times to attain an average for the CIE L*a*b* coordinates and to attain the corresponding Vita Classical shade tab integrated in the software of both devices. Vita tabs were also described as L*a*b* values using earlier published translations so that color differences (ΔE) could be calculated between them. The regression analysis between the two devices showed that the independent correlation coefficients of the L*a*b* values are low. Yet when the suggested shade codes are compared with Vita colors instead of L*a*b*, 40% of the cases were equal and 51% were clinically acceptable. According to this study the two devices do not give a comparable shade selection output, and thus the exchange of L*a*b* values between the two spectrophotometers cannot be recommended.

  8. Automated spectrophotometer for plutonium and uranium determination

    International Nuclear Information System (INIS)

    Jackson, D.D.; Hodgkins, D.J.; Hollen, R.M.; Rein, J.E.

    1975-09-01

    The automated spectrophotometer described is the first in a planned series of automated instruments for determining plutonium and uranium in nuclear fuel cycle materials. It has a throughput rate of 5 min per sample and uses a highly specific method of analysis for these elements. The range of plutonium and uranium measured is 0.5 to 14 mg and 1 to 14 mg, respectively, in 0.5 ml or less of solution with an option to pre-evaporate larger volumes. The precision of the measurements is about 0.02 mg standard deviation over the range corresponding to about 2 rel percent at the 1-mg level and 0.2 rel percent at the 10-mg level. The method of analysis involves the extraction of tetrapropylammonium plutonyl and uranyl trinitrate complexes into 2-nitropropane and the measurement of the optical absorbances in the organic phase at unique peak wavelengths. Various aspects of the chemistry associated with the method are presented. The automated spectrophotometer features a turntable that rotates as many as 24 samples in tubes to a series of stations for the sequential chemical operations of reagent addition and phase mixing to effect extraction, and then to a station for the absorbance measurement. With this system, the complications of sample transfers and flow-through cells are avoided. The absorbance measurement system features highly stable interference filters and a microcomputer that controls the timing sequence and operation of the system components. Output is a paper tape printout of three numbers: a four-digit number proportional to the quantity of plutonium or uranium, a two-digit number that designates the position of the tube in the turntable, and a one-digit number that designates whether plutonium or uranium was determined. Details of the mechanical and electrical components of the instrument and of the hardware and software aspects of the computerized control system are provided

  9. [Design of Dual-Beam Spectrometer in Spectrophotometer for Colorimetry].

    Science.gov (United States)

    Liu, Yi-xuan; Yan, Chang-xiang

    2015-07-01

    Spectrophotometers for colorimetry are usually composed of two independent and identical spectrometers. In order to reduce the volume of spectrophotometer for colorimetry, a design method of double-beam spectrometer is put forward. A traditional spectrometer is modified so that a new spectrometer can realize the function of double spectrometers, which is especially suitable for portable instruments. One slit is replaced by the double-slit, than two beams of spectrum can be detected. The working principle and design requirement of double-beam spectrometer are described. A spectrometer of portable spectrophotometer is designed by this method. A toroidal imaging mirror is used for the Czerny-Turner double-beam spectrometer in this paper, which can better correct astigmatism, and prevent the dual-beam spectral crosstalk. The results demonstrate that the double-beam spectrometer designed by this method meets the design specifications, with the spectral resolution less than 10 nm, the spectral length of 9.12 mm, and the volume of 57 mm x 54 mm x 23 mm, and without the dual-beam spectral overlap in the detector either. Comparing with a traditional spectrophotometer, the modified spectrophotometer uses a set of double-beam spectrometer instead of two sets of spectrometers, which can greatly reduce the volume. This design method can be specially applied in portable spectrophotometers, also can be widely applied in other double-beam spectrophotometers, which offers a new idea for the design of dual-beam spectrophotometers.

  10. The ASTRA Spectrophotometer: Design and Overview

    Science.gov (United States)

    Adelman, S. J.; Gulliver, A. F.; Smalley, B.; Pazder, J. S.; Younger, P. F.; Boyd, L. J.; Epand, D.; Younger, T.

    2007-04-01

    The ASTRA Cassegrain Spectrophotometer and its automated 0.5-m f/16 telescope will soon be working together at the Fairborn Observatory near Nogales, Arizona. Scientific observations are expected to begin in 2007. We provide an overview of this project and review the design of the system. A separate paper in these Proceedings presents details of the data reduction and flux calibrations. The Nogales site averages 150 photometric nights per year. ASTRA should observe stars whose declinations are in the range +80° to -35°. In an hour the system should obtain S/N = 200 observations of stars as faint as 9.5 mag after correction for instrumental errors. Vega will require about 25 seconds for observation and CCD readout. Usually the telescope will find its next target in less than a minute. A small CCD camera finds and centers the target and a second then guides on the zeroth order spectrum. The spectrophotometer uses both a grating and a cross-dispersing prism to produce spectra from both the first and the second orders simultaneously. The square 30 arc second sky fields for each order do not overlap. The resolution is 7 Å in second and 14 Å in first order. The wavelength range is approximately λλ3300-9000. We are initially using about 10 minutes/hour to observe Vega and secondary standard candidates. Our scientific CCD is electronically cooled to -50° C with a water recirculation system heat sink. The same 4° C recycling water system provides thermal stabilization of the instrument. Our flat fielding system uses a second 0.5-m telescope to produce a collimated beam from a 100 μm pinhole illuminated by a quartz halogen lamp. When the two telescopes point at one another this ``artificial star" is focused by the ASTRA telescope which is then rocked to expose the image from the top to the bottom of the entrance aperture. A LINUX HP server at The Citadel will have databases of ASTRA observations. Each observing request has its own priority and observing window

  11. A UV-Vis photoacoustic spectrophotometer.

    Science.gov (United States)

    Wiegand, Joseph R; Mathews, L Dalila; Smith, Geoffrey D

    2014-06-17

    A novel photoacoustic spectrophotometer (PAS) for the measurement of gas-phase and aerosol absorption over the UV-visible region of the spectrum is described. Light from a broadband Hg arc lamp is filtered in eight separate bands from 300 to 700 nm using bandpass interference filters (centered at 301 nm, 314 nm, 364 nm, 405 nm, 436 nm, 546 nm, 578 and 687 nm) and modulated with an optical chopper before entering the photoacoustic cell. All wavelength bands feature a 20-s detection limit of better than 3.0 Mm(-1) with the exception of the lower-intensity 687 nm band for which it is 10.2 Mm(-1). Validation measurements of gas-phase acetone and nigrosin aerosol absorption cross sections at several wavelengths demonstrate agreement to within 10% with those measured previously (for acetone) and those predicted by Mie theory (for nigrosin). The PAS instrument is used to measure the UV-visible absorption spectrum of ambient aerosol demonstrating a dramatic increase in the UV region with absorption increasing by 300% from 405 to 301 nm. This type of measurement throughout the UV-visible region and free from artifacts associated with filter-based methods has not been possible previously, and we demonstrate its promise for classifying and quantifying different types of light-absorbing ambient particles.

  12. Development of a New Reference Spectrophotometer

    Science.gov (United States)

    Zwinkels, Joanne C.; Gignac, Denis S.

    1989-09-01

    A new reference spectrophotometer is being developed at the National Research Council of Canada (NRCC) for high-accuracy transmittance measurements over the spectral range 200 to 2500 nm. This computerized instrument is a single-beam design based upon a servomotor-driven double monochromator with a wavelength resolution of 0.022 nm. The other main components are: (1) two interchangeable sources (deuterium and tungsten-halogen), (2) two computer-selectable TE-cooled detectors (GaAs photomultiplier tube and PbS cell), (3) all-reflective input and exit optics, and (4) a large sample compartment. The significant feature of the optical system is a large, well-collimated measurement beam: the angle of convergence is 0.7° for a slit height of 7 mm, and the maximal beam size is 37x20 mm. This beam geometry eliminates the need for polarization corrections (using linearly polarized light) or compensation for spatially non-uniform detector responsivity (using averaging sphere). The paper describes the instrument design and presents data from preliminary performance tests. The systematic and random sources of error that have been investigated include: wavelength accuracy and reproducibility, bandpass, beam uniformity, polarization, stray light, system drift and linearity. A new linearity tester has been developed for checking the photometric accuracy. This automated device is based upon the double-aperture method but takes advantage of high precision piezoelectric motors to give a single adjustable aperture. Transmittance measurements of several neutral-density glass filters at 546 nm demonstrate that the photometric precision is better than 0.01% of the measured value and that the photometric accuracy is a few parts in 104. The wavelength scale is accurate to better than ±0.1 nm from 300 to 2500 nm, and is reproducible within ±0.03 nm.

  13. Cuvette and method for measuring refractive index in a spectrophotometer

    DEFF Research Database (Denmark)

    2017-01-01

    Embodiments of the present invention include a cuvette (100) for use in determining a refractive index of a sample matter in a spectrophotometer (600), the cuvette comprising a container (102) for holding the sample matter, the container (102) having an entry window (121) that allows input...... or integrally formed in the container and arranged in the radiation path, the photonic crystal having a grating part (111) causing a reflectance spectrum of the photonic crystal to exhibit a resonance. A spectrophotometer is also provided....

  14. ANALYSIS OF UNCERTAINTY MEASUREMENT IN ATOMIC ABSORPTION SPECTROPHOTOMETER

    OpenAIRE

    NEHA S.MAHAJAN; NITIN K. MANDAVGADE; S.B. JAJU

    2012-01-01

    A spectrophotometer is a photometer that can measure intensity as a function of the light source wavelength. The important features of spectrophotometers are spectral bandwidth and linear range of absorption or reflectance measurement. Atomic absorption spectroscopy (AAS) is a very common technique for detecting chemical composition of elements in metal and its alloy. It is very reliable and simple to use. Quality of result (accuracy) depends on the uncertainty of measurement value of the tes...

  15. Hand-held spectrophotometer design for textile fabrics

    Science.gov (United States)

    Böcekçi, Veysel Gökhan; Yıldız, Kazım

    2017-09-01

    In this study, a hand-held spectrophotometer was designed by taking advantage of the developments in modern optoelectronic technology. Spectrophotometer devices are used to determine the color information from the optic properties of the materials. As an alternative to a desktop spectrophotometer device we have implemented, it is the first prototype, low cost and portable. The prototype model designed for the textile industry can detect the color tone of any fabric. The prototype model consists of optic sensor, processor, display floors. According to the color applied on the optic sensor, it produces special frequency information on its output at that color value. In Arduino type processor, the frequency information is evaluated by the program we have written and the color tone information between 0-255 ton is decided and displayed on the screen.

  16. STUDY OF VARIOUS SOLVENTS FOR PHOLCODINE DETERMINATION USING UV SPECTROPHOTOMETER

    OpenAIRE

    Ajay Sharma

    2013-01-01

    Pholcodine is an opioid cough suppressant (anti-tussive). The objective of this work was study of various solvents for Pholcodine determination using UV Spectrophotometer and to develop a new method for determination of the Pholcodine by using UV-Visible Spectrophotometer that would be more accurate and cheapest. A number of solvents were used during the study those were methanol, chloroform, water, 0.1N KOH and 0.1N HCL that were soluble in Pholcodine and by using absorbance method at (285±...

  17. Reliability of shade selection using an intraoral spectrophotometer.

    Science.gov (United States)

    Witkowski, Siegbert; Yajima, Nao-Daniel; Wolkewitz, Martin; Strub, Jorge R

    2012-06-01

    In this study, we evaluate the accuracy and reproducibility of human tooth shade selection using a digital spectrophotometer. Variability among examiners and illumination conditions were tested for possible influence on measurement reproducibility. Fifteen intact anterior teeth of 15 subjects were evaluated for their shade using a digital spectrophotometer (Crystaleye, Olympus, Tokyo, Japan) by two examiners under the same light conditions representing a dental laboratory situation. Each examiner performed the measurement ten times on the labial surface of each tooth containing three evaluation sides (cervical, body, incisal). Commission International on Illumination color space values for L* (lightness), a* (red/green), and b* (yellow/blue) were obtained from each evaluated side. Examiner 2 repeated the measurements of the same subjects under different light conditions (i.e., a dental unit with a chairside lamp). To describe measurement precision, the mean color difference from the mean metric was used. The computed confidence interval (CI) value 5.228 (4.6598-5.8615) reflected (represented) the validity of the measurements. Least square mean analysis of the values obtained by examiners 1 and 2 or under different illumination conditions revealed no statistically significant differences (CI = 95%). Within the limits of the present study, the accuracy and reproducibility of dental shade selection using the tested spectrophotometer with respect to examiner and illumination conditions reflected the reliability of this device. This study suggests that the tested spectrophotometer can be recommended for the clinical application of shade selection.

  18. Fiber optic modification of a diode array spectrophotometer

    International Nuclear Information System (INIS)

    Van Hare, D.R.; Prather, W.S.

    1986-01-01

    Fiber optics were adapted to a Hewlett-Packard diode array spectrophotometer to permit the analysis of radioactive samples without risking contamination of the instrument. Instrument performance was not compromised by the fiber optics. The instrument is in routine use at the Savannah River Plant control laboratories

  19. Performance assessment of Vita Easy Shade spectrophotometer on colour measurement of aesthetic dental materials.

    Science.gov (United States)

    AlGhazali, N; Burnside, G; Smith, R W; Preston, A J; Jarad, F D

    2011-12-01

    Four different shades were used to produce 20 samples of resin-based composite and 20 samples of porcelain to evaluate the performance ability of an intra oral test spectrophotometer compared to a reference spectrophotometer. The absolute colour coordinates CIELAB values measured with both spectrophotometers were significantly different (p spectrophotometers (p < 0.05). Therefore, the Easy Shade can be used in dental practice and dental research with some limitations.

  20. Non-focusing optics spectrophotometer, and methods of use

    Science.gov (United States)

    Kramer, David M.; Sacksteder, Colette A.

    2004-11-02

    In one aspect, the present invention provides kinetic spectrophotometers that each comprise: (a) a light source; and (b) a compound parabolic concentrator disposed to receive light from the light source and configured to (1) intensify and diffuse the light received from the light source, and (2) direct the intensified and diffused light onto a sample. In other aspects, the present invention provides methods for measuring a photosynthetic parameter, the methods comprising the steps of: (a) illuminating a plant leaf until steady-state photosynthesis is achieved; (b) subjecting the illuminated plant leaf to a period of darkness; (c) using a kinetic spectrophotometer of the invention to collect spectral data from the plant leaf treated in accordance with steps (a) and (b); and (d) determining a value for a photosynthetic parameter from the spectral data.

  1. Dobson spectrophotometer ozone measurements during international ozone rocketsonde intercomparison

    Science.gov (United States)

    Parsons, C. L.

    1980-01-01

    Measurements of the total ozone content of the atmosphere, made with seven ground based instruments at a site near Wallops Island, Virginia, are discussed in terms for serving as control values with which the rocketborne sensor data products can be compared. These products are profiles of O3 concentration with altitude. By integrating over the range of altitudes from the surface to the rocket apogee and by appropriately estimating the residual ozone amount from apogee to the top of the atmosphere, a total ozone amount can be computed from the profiles that can be directly compared with the ground based instrumentation results. Dobson spectrophotometers were used for two of the ground-based instruments. Preliminary data collected during the IORI from Dobson spectrophotometers 72 and 38 are presented. The agreement between the two and the variability of total ozone overburden through the experiment period are discussed.

  2. 21 CFR 862.2300 - Colorimeter, photometer, or spectrophotometer for clinical use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Colorimeter, photometer, or spectrophotometer for... Clinical Laboratory Instruments § 862.2300 Colorimeter, photometer, or spectrophotometer for clinical use. (a) Identification. A colorimeter, a photometer, or a spectrophotometer for clinical use is an...

  3. 21 CFR 862.2850 - Atomic absorption spectrophotometer for clinical use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Atomic absorption spectrophotometer for clinical... Laboratory Instruments § 862.2850 Atomic absorption spectrophotometer for clinical use. (a) Identification. An atomic absorption spectrophotometer for clinical use is a device intended to identify and measure...

  4. Performance evaluation of transformer oil using uv-visible spectrophotometer

    OpenAIRE

    Karthik, Radha; National Engineering College; Raja, Thangaswamy Sree Renga; Anna University; Shunmugam, Sundaram Sudalai; National Engineering College

    2014-01-01

    To ensure reliable operation of Power transformer, condition monitoring of transformer becomes obligatory. In this paper, condition assessment of transformer oil under various working conditions is performed using UV-visible spectrophotometer. Test samples include both laboratorial prepared ones and those obtained from in service transformers.  An index table of spectral responses for various faults which predominantly occur in the transformer is developed. The index table will acts as a refe...

  5. Spectrophotometer-Integrating-Sphere System for Computing Solar Absorptance

    Science.gov (United States)

    Witte, William G., Jr.; Slemp, Wayne S.; Perry, John E., Jr.

    1991-01-01

    A commercially available ultraviolet, visible, near-infrared spectrophotometer was modified to utilize an 8-inch-diameter modified Edwards-type integrated sphere. Software was written so that the reflectance spectra could be used to obtain solar absorptance values of 1-inch-diameter specimens. A descriptions of the system, spectral reflectance, and software for calculation of solar absorptance from reflectance data are presented.

  6. [Design of a portable UV-Vis spectrophotometer].

    Science.gov (United States)

    Wan, Feng; Sun, Hong-wei; Fan, Shi-fu

    2006-04-01

    In the present paper, a method for how to design a portable UV-Vis spectrophotometer is introduced. The Hamamatsu multichannel detector S3904-1024Q and a flat field concave grating are employed to design a miniaturized dispersion system. In order to solve the contradiction between the spectral width and energy-utilizing ratio of the light source, a multi-band optical fiber is employed, one side of which is arranged to be rectangle as the entrance slit. The touch screen is employed as the input and output system of the spectrophotometer, and the miniaturized fiber-optic UV-Vis light source is employed as the light source. The research results and testing results of the prototype show that the new spectrophotometer based on the authors' new method is of miniaturization in volume(190 mm x 170 mm x 100 mm), can realize multi-wavelength-detection on-line, and is easily handled (touch screen control), and its performance accords with the Chinese national standard.

  7. [In vivo model to evaluate the accuracy of complete-tooth spectrophotometer for dental clinics].

    Science.gov (United States)

    Liu, Feng; Yang, Jian; Xu, Tong-Kai; Xu, Ming-Ming; Ma, Yu

    2011-02-01

    To test ΔE between measured value and right value from the Crystaleye complete-tooth spectrophotometer, and to evaluate the accuracy rate of the spectrophotometer. Twenty prosthodontists participated in the study. Each of them used Vita 3D-Master shadeguide to do the shade matching, and used Crystaleye complete-tooth spectrophotometer (before and after the test training) tested the middle of eight fixed tabs from shadeguide in the dark box. The results of shade matching and spectrophotometer were recorded. The accuracy rate of shade matching and the spectrophotometer before and after training were calculated. The average accuracy rate of shade matching was 49%. The average accuracy rate of the spectrophotometer before and after training was 83% and 99%. The accuracy of the spectrophotometer was significant higher than that in shade matching, and training can improve the accuracy rate.

  8. Inexpensive Digital Monitoring of Signals from a Spectronic-20 Spectrophotometer

    Science.gov (United States)

    Amend, John R.; Morgan, Matthew E.; Whitla, Alex

    2000-02-01

    Obsolete analog-readout vacuum-tube and solid-state Spectronic-20 family spectrophotometers can be found in most college and university chemistry laboratories. While optically these are good single-beam instruments, their electronics package does not permit attachment of recorders or digital displays. This article describes a simple modification that costs less than $10.00 for parts and will permit direct digital readout of the Spectronic-20 signal with a digital voltmeter or a laboratory interface and a computer. When the external plug is removed, the Spectronic-20 reverts to its normal operating mode.

  9. Dual-beam near-infrared Hadamard spectrophotometer

    OpenAIRE

    da Silva, HEB; Pasquini, C

    2001-01-01

    A dual-beam Hadamard multiplexed spectrophotometer is described. The instrument is intended to work in the near-infrared region of the electromagnetic spectrum (900-1800 nm) and is based on the use of a linear Hadamard mask containing 255 multiplexing elements, Simple symmetric Czerny-Turner optics were employed based on 10 cm diameter, 20 cm focus spherical mirrors and a plane grating containing 295 grooves mm(-1). The dual-path system employs the multiplexed beam exiting from the mask, whic...

  10. Simple LED spectrophotometer for analysis of color information.

    Science.gov (United States)

    Kim, Ji-Sun; Kim, A-Hee; Oh, Han-Byeol; Goh, Bong-Jun; Lee, Eun-Suk; Kim, Jun-Sik; Jung, Gu-In; Baek, Jin-Young; Jun, Jae-Hoon

    2015-01-01

    A spectrophotometer is the basic measuring equipment essential to most research activity fields requiring samples to be measured, such as physics, biotechnology and food engineering. This paper proposes a system that is able to detect sample concentration and color information by using LED and color sensor. Purity and wavelength information can be detected by CIE diagram, and the concentration can be estimated with purity information. This method is more economical and efficient than existing spectrophotometry, and can also be used by ordinary persons. This contribution is applicable to a number of fields because it can be used as a colorimeter to detect the wavelength and purity of samples.

  11. Ultraviolet spectrophotometer for measuring columnar atmospheric ozone from aircraft

    Science.gov (United States)

    Hanser, F. A.; Sellers, B.; Briehl, D. C.

    1978-01-01

    An ultraviolet spectrophotometer (UVS) to measure downward solar fluxes from an aircraft or other high altitude platform is described. The UVS uses an ultraviolet diffuser to obtain large angular response with no aiming requirement, a twelve-position filter wheel with narrow (2-nm) and broad (20-nm) bandpass filters, and an ultraviolet photodiode. The columnar atmospheric ozone above the UVS (aircraft) is calculated from the ratios of the measured ultraviolet fluxes. Comparison with some Dobson station measurements gives agreement to 2%. Some UVS measured ozone profiles over the Pacific Ocean for November 1976 are shown to illustrate the instrument's performance.

  12. UV-observations with a Brewer spectrophotometer at Hohenpeissenberg

    Science.gov (United States)

    Vandersee, Winfried; Koehler, U.

    1994-01-01

    Regular spectral UV-B measurements with a Brewer spectrophotometer have been performed at Hohenpeissenberg since 1990. Intercomparison of the Brewer instrument with other UV-B monitoring devices have shown agreement to within plus or minus 10 percent. Comparisons of UV-B spectra measured on fair weather days reveal the well known increasing influence of ozone on UV-B irradiance with decreasing wavelengths. The integral amplification factor the erythemal irradiance reaches values up to 2.8, which can be diminished by increasing turbidity. The influence of cirrus cloud on the UV-B is also shown.

  13. Automated atomic absorption spectrophotometer, utilizing a programmable desk calculator

    International Nuclear Information System (INIS)

    Futrell, T.L.; Morrow, R.W.

    1977-01-01

    A commercial, double-beam atomic absorption spectrophotometer has been interfaced with a sample changer and a Hewlett-Packard 9810A calculator to yield a completely automated analysis system. The interface electronics can be easily constructed and should be adaptable to any double-beam atomic absorption instrument. The calculator is easily programmed and can be used for general laboratory purposes when not operating the instrument. The automated system has been shown to perform very satisfactorily when operated unattended to analyze a large number of samples. Performance statistics agree well with a manually operated instrument

  14. Portable visible and near-infrared spectrophotometer for triglyceride measurements.

    Science.gov (United States)

    Kobayashi, Takanori; Kato, Yukiko Hakariya; Tsukamoto, Megumi; Ikuta, Kazuyoshi; Sakudo, Akikazu

    2009-01-01

    An affordable and portable machine is required for the practical use of visible and near-infrared (Vis-NIR) spectroscopy. A portable fruit tester comprising a Vis-NIR spectrophotometer was modified for use in the transmittance mode and employed to quantify triglyceride levels in serum in combination with a chemometric analysis. Transmittance spectra collected in the 600- to 1100-nm region were subjected to a partial least-squares regression analysis and leave-out cross-validation to develop a chemometrics model for predicting triglyceride concentrations in serum. The model yielded a coefficient of determination in cross-validation (R2VAL) of 0.7831 with a standard error of cross-validation (SECV) of 43.68 mg/dl. The detection limit of the model was 148.79 mg/dl. Furthermore, masked samples predicted by the model yielded a coefficient of determination in prediction (R2PRED) of 0.6856 with a standard error of prediction (SEP) and detection limit of 61.54 and 159.38 mg/dl, respectively. The portable Vis-NIR spectrophotometer may prove convenient for the measurement of triglyceride concentrations in serum, although before practical use there remain obstacles, which are discussed.

  15. PC based data system for infrared spectrophotometer PU-9512

    International Nuclear Information System (INIS)

    Ali, Mohd Yakub; Venkiteswaran, S.; Nagar, M.S.

    2000-08-01

    This report summarises the upgrading of an old Infra Red Spectrophotometer using a pc for control, data acquisition, storage and analysis. The hardware link is made through RS232C serial port. The control and data management is achieved through software. A brief account of the facilities provided and versatility of the analysis package which was developed in-house in a user friendly menu driven fashion is given here. This is supported by the analysis and inter comparison of infra red spectra of organic/inorganic reactants and products. It has specific application in synthesis and characterization of new extractants, solvents, actinide and lanthanide complexes and in the study of thermally and radiolytically degraded products. (author)

  16. [Development of high speed UV-Vis spectrophotometer].

    Science.gov (United States)

    Huang, Mei-zhen; Ni, Yi; Lin, Feng; Yuan, Bo; Dou, Xiao-ming; Zhao, Hai-ying; Huang, Wei-shi

    2005-06-01

    A high speed spectrophotometer based on a linear CCD was developed. The function and structure of the hardware and the software for the instrument were discussed. The elementary performance was tested as follows: wavelength range 200-820 nm, full spectrum scan time < 0.1 s, spectral bandwidth 0.7 nm, wavelength accuracy +/-1 nm, photometric accuracy +/- 0.005 AU, baseline flatness < 0.001 AU (rms), and stray light < 0.1%. Results showed that this instrument is easy to use, fast and with high analytical performance. In addition, it has internet function of remote control and remote access. With the powerful data processing and spectrum analyzing software, it will provide a strong tool for routine analysis and the research on dynamic reaction in chemistry and biology fields.

  17. Estimation of total alkaloid in Chitrakadivati by UV-Spectrophotometer.

    Science.gov (United States)

    Ajanal, Manjunath; Gundkalle, Mahadev B; Nayak, Shradda U

    2012-04-01

    Herbal formulation standardization by adopting newer technique is need of the hour in the field of Ayurvedic pharmaceutical industry. As very few reports exist. These kind of studies would certainly widen the herbal research area. Chitrakadivati is one such popular herbal formulation used in Ayurveda. Many of its ingredients are known for presence of alkaloids. Presence of alkaloid was tested qualitatively by Dragondroff's method then subjected to quantitative estimation by UV-Spectrophotometer. This method is based on the reaction between alkaloid and bromocresol green (BCG). Study discloses that out of 16 ingredients, 9 contain alkaloid. Chitrakadivati has shown 0.16% of concentration of alkaloid and which is significantly higher than it's individual ingredients.

  18. Early results from the Far Infrared Absolute Spectrophotometer (FIRAS)

    Science.gov (United States)

    Mather, J. C.; Cheng, E. S.; Shafer, R. A.; Eplee, R. E.; Isaacman, R. B.; Fixsen, D. J.; Read, S. M.; Meyer, S. S.; Weiss, R.; Wright, E. L.

    1991-01-01

    The Far Infrared Absolute Spectrophotometer (FIRAS) on the Cosmic Background Explorer (COBE) mapped 98 percent of the sky, 60 percent of it twice, before the liquid helium coolant was exhausted. The FIRAS covers the frequency region from 1 to 100/cm with a 7 deg angular resolution. The spectral resolution is 0.2/cm for frequencies less than 20/cm and 0.8/cm for higher frequencies. Preliminary results include: a limit on the deviations from a Planck curve of 1 percent of the peak brightness from 1 to 20/cm, a temperature of 2.735 +/- 0.06 K, a limit on the Comptonization parameter y of 0.001, on the chemical potential parameter mu of 0.01, a strong limit on the existence of a hot smooth intergalactic medium, and a confirmation that the dipole anisotropy spectrum is that of a Doppler shifted blackbody.

  19. Time course of ultraviolet-induced skin reactions evaluated by two different reflectance spectrophotometers: DermaSpectrophotometer and Minolta spectrophotometer CM-2002.

    Science.gov (United States)

    Park, Seok-Beom; Huh, Chang-Hun; Choe, Yong-Beom; Youn, Jai-Il

    2002-02-01

    Many attempts have been made to quantify ultraviolet (UV)-induced erythema and pigmentation, but most studies have been focused on the initial changes of reaction for a few hours or days and neglected the later events. : A time course of skin colour changes induced by fluorescent sunlamp with a broad band of UVA and UVB radiation was evaluated in 15 Korean male volunteers using two different reflectance spectrophotometers for 28 days. The results were presented by E (erythema)- and M (melanin)-index as well as values converted to the L*a*b* system recommended by the CIE (Commission Internationale de l'Eclairage). The mean individual typology angle of the subjects was 46.6 degrees, which indicated "light" group in constitutional skin colour category. A day after UV exposure, the L* and b* values decreased significantly, following the colour direction of persistent pigment darkening. The values went in the opposite direction persistently until after the 1st week, when maximum tanning was obtained. They then shifted toward their original positions, parallel to the constitutive melanization axis. The a* index showed a significant increase toward the mean colour of haemoglobin on day 1. It returned to its original value along the constitutive melanization axis. The E-index showed a maximum value at day 1, then returned to baseline. The value of M-index reached a peak at day 7. There was no significant difference between the two instruments, but each has its own characteristic features. These promising quantitative methods should enable us to achieve objective measurement of the dermatophysiologic changes and to evaluate the efficacy of therapeutic modalities on skin disorders without the inherent errors associated with subjective judgement. Our results provide standard data on a time course of UV-induced skin erythema and pigmentation.

  20. The Spectrophotometer II: A Module on the Spectral Properties of Light. Tech Physics Series.

    Science.gov (United States)

    Frank, Nathaniel; And Others

    This module is designed to give the learner an understanding of the nature of light and how its properties are used in the design of spectrophotometers. Problems promote the use of spectrophotometers in qualitative analysis, the optical elements used in a monochromator, and the physical properties of the prism and the diffraction grating. Other…

  1. Manufacturing Initiative

    Data.gov (United States)

    National Aeronautics and Space Administration — The Advanced Manufacturing Technologies (AMT) Project supports multiple activities within the Administration's National Manufacturing Initiative. A key component of...

  2. Comparation studies of uranium analysis method using spectrophotometer and voltammeter

    International Nuclear Information System (INIS)

    Sugeng Pomomo

    2013-01-01

    Comparation studies of uranium analysis method by spectrophotometer and voltammeter had been done. The objective of experiment is to examine the reliability of analysis method and instrument performance by evaluate parameters; linearity, accuracy, precision and detection limit. Uranyl nitrate hexahydrate is used as standard, and the sample is solvent mixture of tributyl phosphate and kerosene containing uranium (from phosphoric acid purification unit Petrokimia Gresik). Uranium (U) stripping in the sample use HN0 3 0,5 N and then was analyzed by using of both instrument. Analysis of standard show that both methods give a good linearity by correlation coefficient > 0,999. Spectrophotometry give accuration 99,34 - 101,05 % with ratio standard deviation (RSD) 1,03 %; detection limit (DL) 0,05 ppm. Voltammetry give accuration 95,63 -101,49 % with RSD 3,91 %; detection limit (DL) 0,509 ppm. On the analysis of sludge samples were given the significantly different in result; spectrophotometry give U concentration 4,445 ppm by RSD 6,74 % and voltammetry give U concentration 7,693 by RSD 19,53%. (author)

  3. Construction of a photochemical reactor combining a CCD spectrophotometer and a LED radiation source.

    Science.gov (United States)

    Gombár, Melinda; Józsa, Éva; Braun, Mihály; Ősz, Katalin

    2012-10-01

    An inexpensive photoreactor using LED light sources and a fibre-optic CCD spectrophotometer as a detector was built by designing a special cell holder for standard 1.000 cm cuvettes. The use of this device was demonstrated by studying the aqueous photochemical reaction of 2,5-dichloro-1,4-benzoquinone. The developed method combines the highly quantitative data collection of CCD spectrophotometers with the possibility of illuminating the sample independently of the detecting light beam, which is a substantial improvement of the method using diode array spectrophotometers as photoreactors.

  4. Skin color analysis using a spectrophotometer in Asians.

    Science.gov (United States)

    Yun, In Sik; Lee, Won Jai; Rah, Dong Kyun; Kim, Yong Oock; Park, Be-young Yun

    2010-08-01

    To objectively describe skin color, the Commission International d'Eclairage (CIE) L*a*b* color coordinates and melanin and erythema indexes are used. However, it was difficult to understand the relationship among these parameters and to convert them into each other. We introduced a new technique to measure L*a*b* color coordinates and the melanin and erythema indexes at the same time. We analyzed the skin color of normal Asians using this method. The skin color of the forehead, cheek, upper inner arm, dorsum of hand, and anterior chest of 148 volunteers was measured using a spectrophotometer. Using a computer analysis program, L*a*b* values and the melanin and erythema indexes were presented at the same time. The averages of these data were shown according to gender, age, body parts, and correlations among the melanin and erythema indexes and L*a*b* color coordinates, and then they were analyzed. The averages of the melanin and erythema indexes of 148 participants were 1.10 +/- 0.29 and 1.29 +/- 0.38, respectively. The averages of the L*, a*, and b* values were 64.15 +/- 4.86, 8.96 +/- 2.65, and 18.34 +/- 2.39, respectively. The melanin and erythema indexes were higher in males than in females. While the correlation of the melanin index with the L* value was negative, it was positively correlated with the a* and b* values. While the erythema index showed a weak correlation with the b* value, its correlation was negative with the L* value and positive with the a* value. Our method of skin color measurement is useful. We consider the data of this study valuable basic data for the evaluation of colors of pigmental skin diseases and scars in the future.

  5. An extinction scale-expansion unit for the Beckman DK2 spectrophotometer

    Science.gov (United States)

    Dixon, M.

    1967-01-01

    The paper describes a simple but accurate unit for the Beckman DK2 recording spectrophotometer, whereby any 0·1 section of the extinction (`absorbance') scale may be expanded tenfold, while preserving complete linearity in extinction. PMID:6048800

  6. Instrumentation-related uncertainty of reflectance and transmittance measurements with a two-channel spectrophotometer

    OpenAIRE

    Peest, Christian; Schinke, Carsten; Brendel, Rolf; Schmidt, Jan; Bothe, Karsten

    2017-01-01

    Spectrophotometers are operated in numerous fields of science and industry for a variety of applications. In order to provide confidence for the measured data, analyzing the associated uncertainty is valuable. However, the uncertainty of the measurement results is often unknown or reduced to sample-related contributions. In this paper, we describe our approach for the systematic determination of the measurement uncertainty of the commercially available two-channel spectrophotometer Agilent Ca...

  7. Using a digital multimeter to capture spectral information generated by a spectrophotometer broadcast / atomic absorption

    International Nuclear Information System (INIS)

    Villalobos Chaves, Alberto E.

    2006-01-01

    Spectral analysis capability of the information generated by a spectrophotometer broadcast / shimadzu AA 640-13 atomic absorption has increased, through the capture of data, using a digital multimeter as the interface between the spectrophotometer and a computer. To facilitate the identification of analytes was created Chromulan format files for the 99 chemical elements reported in the literature, and covering the region between 200 nm and 900 nm, the subject of this study. (author) [es

  8. Versatile IEEE-488 data acquisition and control routines for a diode array spectrophotometer

    Science.gov (United States)

    Shiundu, Paul M.

    1991-01-01

    The UV-visible diode array spectrophotometer is a work-horse instrument for many laboratories. This article provides simple data acquisition and control routines in Microsoft QuickBasic for a HP-8452A diode array spectrophotometer interfaced to an IBM PC/XT/AT, or compatible, microcomputer. These allow capture of full spectra and measure absorbance at one or several wavelengths at preset time intervals. The variance in absorbance at each wavelength is available as an option. PMID:18924888

  9. Versatile IEEE-488 data acquisition and control routines for a diode array spectrophotometer

    OpenAIRE

    Shiundu, Paul M.; Wade, Adrian P.

    1991-01-01

    The UV-visible diode array spectrophotometer is a work-horse instrument for many laboratories. This article provides simple data acquisition and control routines in Microsoft QuickBasic for a HP-8452A diode array spectrophotometer interfaced to an IBM PC/XT/AT, or compatible, microcomputer. These allow capture of full spectra and measure absorbance at one or several wavelengths at preset time intervals. The variance in absorbance at each wavelength is available as an option.

  10. Manufacturing Interfaces

    NARCIS (Netherlands)

    van Houten, Frederikus J.A.M.

    1992-01-01

    The paper identifies the changing needs and requirements with respect to the interfacing of manufacturing functions. It considers the manufacturing system, its components and their relationships from the technological and logistic point of view, against the background of concurrent engineering.

  11. Precision manufacturing

    CERN Document Server

    Dornfeld, David

    2008-01-01

    Today there is a high demand for high-precision products. The manufacturing processes are now highly sophisticated and derive from a specialized genre called precision engineering. Precision Manufacturing provides an introduction to precision engineering and manufacturing with an emphasis on the design and performance of precision machines and machine tools, metrology, tooling elements, machine structures, sources of error, precision machining processes and precision process planning. As well as discussing the critical role precision machine design for manufacturing has had in technological developments over the last few hundred years. In addition, the influence of sustainable manufacturing requirements in precision processes is introduced. Drawing upon years of practical experience and using numerous examples and illustrative applications, David Dornfeld and Dae-Eun Lee cover precision manufacturing as it applies to: The importance of measurement and metrology in the context of Precision Manufacturing. Th...

  12. Clinical evaluation of a dental color analysis system: the Crystaleye Spectrophotometer®.

    Science.gov (United States)

    Odaira, Chikayuki; Itoh, Sozo; Ishibashi, Kanji

    2011-10-01

    To evaluate the clinical performance of the Crystaleye Spectrophotometer(®), a dental color analysis system. Three color-measuring devices (Crystaleye Spectrophotometer(®), CAS-ID1, MSC-2000) were tested and the differences in color measurements among them were evaluated using Scheffe's F-test. Color measurements with the Crystaleye Spectrophotometer(®) were repeated 10 times by the same operator. The color difference (ΔE) between the first and tenth measurements was calculated. The Crystaleye Spectrophotometer(®) was used to measure the color of the maxillary left central incisor under two conditions (light and dark) and the effect of exterior lighting was analyzed to assess the accuracy of measurements. Furthermore, five different operators performed color measurements, and ΔE among the three devices was calculated. The ΔE between the target tooth and the crown of a single maxillary central incisor crown fabricated using data from the Crystaleye Spectrophotmeter(®) was calculated. Color differences between prebleaching and postbleaching were also analyzed with the Crystaleye Spectrophotometer(®) using the parameters ΔE, ΔL*, Δa*, and Δb*. The data from the three spectrophotometers were not significantly different. The ΔE during repeated color measurements by the same operator was 0.6. The ΔE between light and dark conditions was 0.9. The data from the five operators were not significantly different. The mean ΔE value between the target tooth and the fabricated crown was 1.2 ± 0.4, and the mean ΔE value between prebleaching and postbleaching was 3.7 ± 1.0. The Crystaleye Spectrophotometer(®) is an easy-to-use color analysis system producing accurate color measurements under clinical conditions. Copyright © 2011 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  13. Measurement of protein-like fluorescence in river and waste water using a handheld spectrophotometer.

    Science.gov (United States)

    Baker, Andy; Ward, David; Lieten, Shakti H; Periera, Ryan; Simpson, Ellie C; Slater, Malcolm

    2004-07-01

    Protein-like fluorescence intensity in rivers increases with increasing anthropogenic DOM inputs from sewerage and farm wastes. Here, a portable luminescence spectrophotometer was used to investigate if this technology could be used to provide both field scientists with a rapid pollution monitoring tool and process control engineers with a portable waste water monitoring device, through the measurement of river and waste water tryptophan-like fluorescence from a range of rivers in NE England and from effluents from within two waste water treatment plants. The portable spectrophotometer determined that waste waters and sewerage effluents had the highest tryptophan-like fluorescence intensity, urban streams had an intermediate tryptophan-like fluorescence intensity, and the upstream river samples of good water quality the lowest tryptophan-like fluorescence intensity. Replicate samples demonstrated that fluorescence intensity is reproducible to +/- 20% for low fluorescence, 'clean' river water samples and +/- 5% for urban water and waste waters. Correlations between fluorescence measured by the portable spectrophotometer with a conventional bench machine were 0.91; (Spearman's rho, n = 143), demonstrating that the portable spectrophotometer does correlate with tryptophan-like fluorescence intensity measured using the bench spectrophotometer.

  14. An ultraviolet-visible spectrophotometer automation system. Part 1: Functional specifications

    Science.gov (United States)

    Roth, G. S.; Teuschler, J. M.; Budde, W. L.

    1982-07-01

    The project definition, the functional requirements, and the functional design for a proposed computer automation system for scanning spectrophotometers are presented. The system will be implemented on a Data General computer using the BASIC language. The system is a real-time data acquisition system with 'on-line' data reduction, quality assurance, report generation and plotting. It is designed for operation with the Environmental Protection Agency (EPA) Data General automation system. Analyses included in the system facilitate the determination of chlorophyll concentrations, the evaluation of color in waters, and a general transmittance/absorbance measurement of any given sample. Quality assurance is provided by the analysis of standard filters. Two related publications are titled, 'An Ultraviolet-Visible Spectrophotometer Automation System - Part II User's Guide' and 'An Ultraviolet-Visible Spectrophotometer Automation System - Part III Program Documentation.'

  15. Novel single-beam optical spectrophotometer for fast luminescence, absorption, and reflection measurements of turbid materials

    Science.gov (United States)

    Schmidt, Werner

    1995-02-01

    A novel spectrophotometer based on the deflection of a secondary element for measuring clear and highly turbid materials within the millisecond time range is developed. The number of optical components of the monochromator is reduced to the absolute minimum. This results in excellent light throughput and a low stray-light level. The spectrophotometer has been designed allowing spectral measurements of absorption, transmission, reflection, and luminescence in a single-beam mode, as documented by various examples. Its design is highly flexible and the price/quality relation might be adopted to the envisaged purpose. The main philosophy is to relocate as many functions as possible form the hardware to the software part of the spectrophotometer. Several novel procedures based on old concepts are proposed. An appropriate computer program providing data acquisition, control functions as well as numerous analytical capabilities is developed on the basis of the compiler language power basic and indispensably 'fast' routines are written in assembler language.

  16. Objective evaluation of whiteness of cooked rice and rice cakes using a portable spectrophotometer.

    Science.gov (United States)

    Goto, Hajime; Asanome, Noriyuki; Suzuki, Keitaro; Sano, Tomoyoshi; Saito, Hiroshi; Abe, Yohei; Chuba, Masaru; Nishio, Takeshi

    2014-03-01

    The whiteness of cooked rice and rice cakes was evaluated using a portable spectrophotometer with a whiteness index (WI). Also, by using boiled rice for measurement of Mido values by Mido Meter, it was possible to infer the whiteness of cooked rice without rice cooking. In the analysis of varietal differences of cooked rice, 'Tsuyahime', 'Koshihikari' and 'Koshinokaori' showed high whiteness, while 'Satonoyuki' had inferior whiteness. The whiteness of rice cakes made from 'Koyukimochi' and 'Dewanomochi' was higher than the whiteness of those made from 'Himenomochi' and 'Koganemochi'. While there was a significant correlation (r = 0.84) between WI values and whiteness scores of cooked rice by the sensory test, no correlation was detected between the whiteness scores and Mido values, indicating that the values obtained by a spectrophotometer differ from those obtained by a Mido Meter. Thus, a spectrophotometer may be a novel device for measurement of rice eating quality.

  17. Additive manufacturing.

    Science.gov (United States)

    Mumith, A; Thomas, M; Shah, Z; Coathup, M; Blunn, G

    2018-04-01

    Increasing innovation in rapid prototyping (RP) and additive manufacturing (AM), also known as 3D printing, is bringing about major changes in translational surgical research. This review describes the current position in the use of additive manufacturing in orthopaedic surgery. Cite this article: Bone Joint J 2018;100-B:455-60.

  18. Shade determination using camouflaged visual shade guides and an electronic spectrophotometer.

    Science.gov (United States)

    Kvalheim, S F; Øilo, M

    2014-03-01

    The aim of the present study was to compare a camouflaged visual shade guide to a spectrophotometer designed for restorative dentistry. Two operators performed analyses of 66 subjects. One central upper incisor was measured four times by each operator; twice with a camouflaged visual shade guide and twice with a spectrophotometer Both methods had acceptable repeatability rates, but the electronic shade determination showed higher repeatability. In general, the electronically determined shades were darker than the visually determined shades. The use of a camouflaged visual shade guide seems to be an adequate method to reduce operator bias.

  19. Micro Manufacturing

    DEFF Research Database (Denmark)

    Hansen, Hans Nørgaard

    2003-01-01

    Manufacturing deals with systems that include products, processes, materials and production systems. These systems have functional requirements, constraints, design parameters and process variables. They must be decomposed in a systematic manner to achieve the best possible system performance...... processes are made applicable to a large number of customers, the pressure in regard to developing production technologies that make it possible to produce the products at a reasonable price and in large numbers is growing. The micro/nano manufacturing programme at the Department of Manufacturing....... If a micro manufacturing system isn’t designed rationally and correctly, it will be high-cost, unreliable, and not robust. For micro products and systems it is a continuously increasing challenge to create the operational basis for an industrial production. As the products through product development...

  20. Smart Manufacturing.

    Science.gov (United States)

    Davis, Jim; Edgar, Thomas; Graybill, Robert; Korambath, Prakashan; Schott, Brian; Swink, Denise; Wang, Jianwu; Wetzel, Jim

    2015-01-01

    Historic manufacturing enterprises based on vertically optimized companies, practices, market share, and competitiveness are giving way to enterprises that are responsive across an entire value chain to demand dynamic markets and customized product value adds; increased expectations for environmental sustainability, reduced energy usage, and zero incidents; and faster technology and product adoption. Agile innovation and manufacturing combined with radically increased productivity become engines for competitiveness and reinvestment, not simply for decreased cost. A focus on agility, productivity, energy, and environmental sustainability produces opportunities that are far beyond reducing market volatility. Agility directly impacts innovation, time-to-market, and faster, broader exploration of the trade space. These changes, the forces driving them, and new network-based information technologies offering unprecedented insights and analysis are motivating the advent of smart manufacturing and new information technology infrastructure for manufacturing.

  1. Analog Spectrophotometers in the Digital Age: Data Acquisition on a Budget

    Science.gov (United States)

    Nazarenko, Alexander Y.; Nazarenko, Natalie A.

    2005-01-01

    The interfacing of various spectrometers with analog output to a personal computer running Microsoft Excel in the Windows environment is described. This low cost data acquisition solution is a useful replacement of a chart recorder for various UV-visible and infrared scanning spectrophotometers.

  2. PMAS: The Potsdam Multi-Aperture Spectrophotometer. II. The Wide Integral Field Unit PPak

    NARCIS (Netherlands)

    Kelz, Andreas; Verheijen, Marc A. W.; Roth, Martin M.; Bauer, Svend M.; Becker, Thomas; Paschke, Jens; Popow, Emil; Sánchez, Sebastian F.; Laux, Uwe

    2006-01-01

    PPak is a new fiber-based integral field unit (IFU) developed at the Astrophysical Institute of Potsdam and implemented as a module into the existing Potsdam Multi-Aperture Spectrophotometer (PMAS) spectrograph. The purpose of PPak is to provide an extended field of view with a large

  3. An Improved Flame Test for Qualitative Analysis Using a Multichannel UV-Visible Spectrophotometer

    Science.gov (United States)

    Blitz, Jonathan P.; Sheeran, Daniel J.; Becker, Thomas L.

    2006-01-01

    Qualitative analysis schemes are used in undergraduate laboratory settings as a way to introduce equilibrium concepts and logical thinking. The main component of all qualitative analysis schemes is a flame test, as the color of light emitted from certain elements is distinctive and a flame photometer or spectrophotometer in each laboratory is…

  4. Spectrophotometer and ultrasound evaluation of late toxicity following breast-cancer radiotherapy.

    Science.gov (United States)

    Yoshida, E J; Chen, H; Torres, M A; Curran, W J; Liu, T

    2011-10-01

    Radiation-induced normal-tissue toxicities are common, complex, and distressing side effects that affect 90% of patients receiving breast-cancer radiotherapy and 40% of patients post radiotherapy. In this study, the authors investigated the use of spectrophotometry and ultrasound to quantitatively measure radiation-induced skin discoloration and subcutaneous-tissue fibrosis. The study's purpose is to determine whether skin discoloration correlates with the development of fibrosis in breast-cancer radiotherapy. Eighteen breast-cancer patients were enrolled in our initial study. All patients were previously treated with a standard course of radiation, and the median follow-up time was 22 months. The treated and untreated breasts were scanned with a spectrophotometer and an ultrasound. Two spectrophotometer parameters-melanin and erythema indices-were used to quantitatively assess skin discoloration. Two ultrasound parameters-skin thickness and Pearson coefficient of the hypodermis-were used to quantitatively assess severity of fibrosis. These measurements were correlated with clinical assessments (RTOG late morbidity scores). Significant measurement differences between the treated and contralateral breasts were observed among all patients: 27.3% mean increase in skin thickness (p spectrophotometer parameters do not correlate with ultrasound parameters. Spectrophotometry and quantitative ultrasound are objective tools that assess radiation-induced tissue injury. Spectrophotometer parameters did not correlate with those of quantitative ultrasound suggesting that skin discoloration cannot be used as a marker for subcutaneous fibrosis. These tools may prove useful for the reduction of radiation morbidities and improvement of patient quality of life.

  5. [An optical-fiber-sensor-based spectrophotometer for soil non-metallic nutrient determination].

    Science.gov (United States)

    He, Dong-xian; Hu, Juan-xiu; Lu, Shao-kun; He, Hou-yong

    2012-01-01

    In order to achieve rapid, convenient and efficient soil nutrient determination in soil testing and fertilizer recommendation, a portable optical-fiber-sensor-based spectrophotometer including immersed fiber sensor, flat field holographic concave grating, and diode array detector was developed for soil non-metallic nutrient determination. According to national standard of ultraviolet and visible spectrophotometer with JJG 178-2007, the wavelength accuracy and repeatability, baseline stability, transmittance accuracy and repeatability measured by the prototype instrument were satisfied with the national standard of III level; minimum spectral bandwidth, noise and excursion, and stray light were satisfied with the national standard of IV level. Significant linear relationships with slope of closing to 1 were found between the soil available nutrient contents including soil nitrate nitrogen, ammonia nitrogen, available phosphorus, available sulfur, available boron, and organic matter measured by the prototype instrument compared with that measured by two commercial single-beam-based and dual-beam-based spectrophotometers. No significant differences were revealed from the above comparison data. Therefore, the optical-fiber-sensor-based spectrophotometer can be used for rapid soil non-metallic nutrient determination with a high accuracy.

  6. Authentic Performance in the Instrumental Analysis Laboratory: Building a Visible Spectrophotometer Prototype

    Science.gov (United States)

    Wilson, Mark V.; Wilson, Erin

    2017-01-01

    In this work we describe an authentic performance project for Instrumental Analysis in which students designed, built, and tested spectrophotometers made from simple components. The project addressed basic course content such as instrument design principles, UV-vis spectroscopy, and spectroscopic instrument components as well as skills such as…

  7. Designing and manufacturing of solar imaging and tracking system

    Directory of Open Access Journals (Sweden)

    Mehrdad Hosseini

    2017-11-01

    Full Text Available Abstract – in this study, designing and manufacturing of solar imaging and tracking system in order to research and spectroscopy applications are investigated. The device has the ability to be used as a Telescope, spectroscope, spectrophotometer and spectrohelioscope. The results obtained from this device are used in the various field of research such as absorption spectra of the surface of the sun, transit of planets in front of the sun, Doppler effects, evaluation of the Fraunhofer lines, plot of intensity versus wavelength and studying of Solar Flares. In this research, design and manufacture of the device, along with some of the results, are reported.

  8. Development of a Novel Spectrophotometer for Biochemical Analyzer Based on Volume Holography Transmissive Grating and Linear CCD

    International Nuclear Information System (INIS)

    Ren Zhong; Liu Guodong; Huang Zhen; Zeng Lvming; Dai Longmin

    2011-01-01

    The classical surface-embossed plane and concave grating are usually used as the diffraction grating in some spectrophotometers. But the minute cracks are produced on the surface of the gratings' grooves, which leads to generate the stray-light and decrease the efficiency of instrument. Therefore, a novel custom-built spectrophotometer for BCA is developed in this paper. Meanwhile, the volume holography transmissive (VHT) grating is used as the diffraction grating in this spectrophotometer. Additionally, a high resolution CCD and data acquisition (DAQ) card with combined the virtual software platform based on LabVIEW are used to design the spectral acquisition and analysis system. Experimental results show that the spectral range and the diffraction efficiency of the spectrophotometer for BCA are greatly increased. The spectral range of the spectrophotometer for BCA can reach 300-1000 nm, its wavelength resolution can reach 1nm. And, it uses the back-splitting-light technology and multi-channel parallel analysis. Compared with other same types, this spectrophotometer has many advantages, such as, higher efficiency, simpler algorithm, higher accuracy, cheaper cost and fewer stray-light and higher imaging quality, etc. Therefore, this spectrophotometer for BCA based on VHT grating will has the greatly potential values in the fields of the biochemical or medical research.

  9. Development of a Bolometer Detector System for the NIST High Accuracy Infrared Spectrophotometer

    Science.gov (United States)

    Zong, Y.; Datla, R. U.

    1998-01-01

    A bolometer detector system was developed for the high accuracy infrared spectrophotometer at the National Institute of Standards and Technology to provide maximum sensitivity, spatial uniformity, and linearity of response covering the entire infrared spectral range. The spatial response variation was measured to be within 0.1 %. The linearity of the detector output was measured over three decades of input power. After applying a simple correction procedure, the detector output was found to deviate less than 0.2 % from linear behavior over this range. The noise equivalent power (NEP) of the bolometer system was 6 × 10−12 W/Hz at the frequency of 80 Hz. The detector output 3 dB roll-off frequency was 200 Hz. The detector output was stable to within ± 0.05 % over a 15 min period. These results demonstrate that the bolometer detector system will serve as an excellent detector for the high accuracy infrared spectrophotometer. PMID:28009364

  10. [Determination of aluminum in sediments by atomic absorption spectrophotometer without FIA spectrophotometric analysis].

    Science.gov (United States)

    Zhao, Zhen-yi; Han, Guang-xi; Song, Xi-ming; Luo, Zhi-xiong

    2008-06-01

    To search for a new method of determining, we developed a new flow injection analyzer, applied to the atomic absorption spectrophotometer, relying on it without flame in place of visible spectrophotometer, and studied the appropriate condition for the determination of aluminum in sediments, thus built up a kind of new analytical test technique. Three peak and two valley absorption values (A1, A2, A3, A4 and A5) can be continuously obtained simultaneously that all can be used for quantitative analysis, then we discussed its theory and experiment technique. Based on the additivity of absorbance (A = A1+A2+A3+A4+ A5), the sensitivity of FIA is enhanced, and its precision and linear relation are also good, raising the efficiency of AAS. The simple method has been applied to determining Al in sediments, and the results are satisfactory.

  11. Differences between the human eye and the spectrophotometer in the shade matching of tooth colour.

    Science.gov (United States)

    Gómez-Polo, Cristina; Gómez-Polo, Miguel; Celemin-Viñuela, Alicia; Martínez Vázquez De Parga, Juan Antonio

    2014-06-01

    The aim of this work was to assess the agreement between instrumental and visual colour matching. Shade selection with the 3DMaster Toothguide (Vita-Zahnfabrik) was performed for 1361 maxillary central incisors and compared with the shade obtained with the EasyShade Compact (Vita-Zahnfabrik) spectrophotometer. We observed a greater correlation between the objective method and the subjective one in the colour dimension of lightness (Kappa 0.6587), followed by hue (Kappa 0.4337) and finally chroma (Kappa 0.3578). The colour dimension in which the greatest agreement is seen between the operator and the spectrophotometer is value or lightness. This study reveals differences between the measurement of colour via spectrophotometry and the visual shade selection method. According to our results, there is better agreement in the value or lightness colour dimension, which is the most important one in the choice of tooth colour. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Application of ZnO Nanoparticle as Sulphide Gas Sensor Using UV/VIS/NIR-Spectrophotometer

    Science.gov (United States)

    Juliasih, N.; Buchari; Noviandri, I.

    2017-04-01

    The nanoparticle of metal oxides has great unique characteristics that applicable to the wide industrial as sensors and catalysts for reducing environmental pollution. Sulphide gas monitors and detectors are required for assessing safety aspects, due to its toxicity level. A thin film of ZnO as the sulphide gas sensor was synthesised by the simple method of chemical liquid deposition with variation of annealing temperature from 200 ºC to 500 ºC, and characterised by Scanning Electron Microscope (SEM), X-Ray Diffraction (XRD), and UV/VIS/NIR-Spectrophotometer. Characterization studies showed nanoparticle size from the range 62 - 92 nm of diameters. The application this ZnO thin film to sulfide gas, detected by UV/VIS/NIR Spectrophotometer with diffuse reflectance, showed specific chemical reaction by the shifting of maximum % Reflectance peak. The gas sensing using this method is applicable at room.

  13. Development of optical spectrum acquisition with spectrophotometer for characterization of optical radiation sources

    International Nuclear Information System (INIS)

    Solano Vargas, Alvaro

    2013-01-01

    An improved process of the data acquisition system is developed with Pasco 750 interface and Pasco OS-8539 spectrophotometer. The optical spectrum and color temperature of incandescent sources available are obtained from the Laboratorio de Fotonica y Tecnologia Laser Aplicada. The procedures developed in the project are recommended to collect data and analyze results. The purchase of a new Software and the interface of Pasco is recommended to have a better operation and update [es

  14. ANALYSIS OF VARIOUS METAL IONS IN SOME MEDICINAL PLANTS USING ATOMIC ABSORPTION SPECTROPHOTOMETER

    OpenAIRE

    Y.L. Ramachandra*, C. Ashajyothi and Padmalatha S. Rai

    2012-01-01

    Metal ions such as iron , lead, copper, nickel, cadmium , chromium and zinc were investigated in medicinally important plants Alstonia scholaris, Tabernaemontana coronariae, Asparagus racemosus, Mimosa pudica, Leucas aspera and Adhatoda vasica applying atomic absorption spectrophotometer techniques. The purpose of this study was to standardize various metal ion Contamination in indigenous medicinal plants. Maximum concentration of lead was present in Leucas aspera and Adhatoda vasica follo...

  15. COMPARATIVE ANALYSIS FOR METAL BINDING CAPACITY OF CYSTEINE BY USING UV-VIS SPECTROPHOTOMETER

    OpenAIRE

    Shivendu Ranjan; Nandita Dasgupta; Gyanendra Gour; Rashmi Dubey; Kumari Amrita

    2012-01-01

    The metal binding capacity of cysteine with three different metals Nickel, Copper and Lead was studied using UV-Vis spectrophotometer for which absorbance values were taken after interaction of cysteine with metal salt solutions (10ppm and 100ppm). Before taking above absorbance dilution factor was set using cysteine stock. The increase in peak intensity was observed when metal salt solution and metal saltcysteine solution were compared. Based on peak shift and peak intensity finally it can b...

  16. Semiconductor emitter based 32-channel spectrophotometer module for real-time process measurements

    Science.gov (United States)

    Keranen, Heimo; Malinen, Jouko

    1990-08-01

    A new type of semiconductor emitter based multichannel spectrophotometer has been designed and tested. The spectrophotometer consists of a small electrically conirolled narrow band light source an optical receiver and microprocessor electronics for data processing. The light source is based on a 32-element GaAs and GaAIAs LED chip array which is connected to a diffraction grating and feedback optics. The source is capable of emitting intensity-stabilized single-beam narrow band light pulses. The wavelength of the light pulse can be selected by the electronics without using any moving parts. The optical mechanical and optoelectronic parts of the source have been integrated to form a compact hybrid construction. Main characteristics have been tested with an experimental 32-channel spectrophotometer designed for the wavelength range 810 nm - 1060 nm. Measured wavelength half-power bandwidths are 8 nm and channel separation is 7. 5 nm. A single spectrum scan can be recorded in 8 ms. 64 scans are averaged by the microprocessor electronics and data is transferred to a PC for a multicomponent spectrum analysis program. Output light power level is better than i05 times the averaged detector noise level. The wavelength range used is optimized for near infrared transmittance (NIT) analysis of agricultural products. 1.

  17. Correlation between skin color evaluation by skin color scale chart and narrowband reflectance spectrophotometer.

    Science.gov (United States)

    Treesirichod, Arucha; Chansakulporn, Somboon; Wattanapan, Pattra

    2014-07-01

    Various methods are available for the evaluation of skin color. A skin color scale chart is a convenient and inexpensive tool. However, the correlation between a skin color scale chart and objective measurement has not been evaluated. To assess the correlation between skin color evaluation done by a skin color scale chart (Felix von Luschan skin color chart) and a narrowband reflectance spectrophotometer (Mexameter MX18). The participants were evaluated for skin color by using the Felix von Luschan skin color chart (range 1-36) and a narrowband reflectance spectrophotometer (Mexameter MX18) in which the results of the measurements were expressed as Erythema (E) and Melanin (M) indices. Skin color was measured on four different anatomical skin sites from each participant on the medial aspect of the volar and the dorsal regions of both forearms. A total of 208 records from 52 participants were established. The majority of participants (19.2%) were rated with the skin color scale at the number 16 (range 14-33). The mean M plus E, M, and E indices were 498.9 ± 143.9, 230.4 ± 74.4, and 268.5 ± 73.2, respectively. The correlation coefficient between the number on the skin color scale and each index: M plus E, M, and E indices were 0.90, 0.90, and 0.86, respectively, with a statistical significance of P spectrophotometer.

  18. Chemical Fouling Reduction of a Submersible Steel Spectrophotometer in Estuarine Environments Using a Sacrificial Zinc Anode.

    Science.gov (United States)

    Tait, Zachary S; Thompson, Megan; Stubbins, Aron

    2015-07-01

    The availability of in situ spectrophotometers, such as the S::CAN spectro::lyser, has expanded the possibilities for high-frequency water quality data collection. However, biological and chemical fouling can degrade the performance of in situ spectrophotometers, especially in saline environments with rapid flow rates. A complex freshwater washing system has been previously designed to reduce chemical fouling for the S::CAN spectro::lyser spectrophotometer. In the current study, we present a simpler, cheaper alternative: the attachment of a sacrificial zinc anode. Results are presented detailing the S::CAN spectro::lyser performance with and without the addition of the sacrificial anode. Attachment of the zinc anode provided efficient corrosion protection during 2-wk deployments in a highly dynamic (average tidal range, 2.5 m) saline tidal saltmarsh creek at Groves Creek, Skidaway Institute of Oceanography, Savannah, GA. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  19. Fiberoptic spectrophotometer

    Science.gov (United States)

    Tans, Petrus P.; Lashof, Daniel A.

    1986-01-01

    A device for determining the relative composition of a sample of a gas by comparison of the Raman-scattered light of the sample with that of a known gas comprising: a means for passing a single light source through the unknown and the known gases, choppers to alternate the Raman-scattered light into a common light detection and measuring system, optical fiber networks for spatially mixing the resulting Raman scattered light from each sample and directing the mixed light to selective detectors, and a compiler to record the light intensity of each wavelength of Raman-scattered light as a function of the sample from which it originated.

  20. Apparel Manufacture

    Science.gov (United States)

    1995-01-01

    Marshall Space Flight Center teamed with the University of Alabama in Huntsville (UAH) in 1989 on a program involving development of advanced simulation software. Concurrently, the State of Alabama chartered UAH to conduct a technology advancement program in support of the state's apparel manufacturers. In 1992, under contract to Marshall, UAH developed an apparel-specific software package that allows manufacturers to design and analyze modules without making an actual investment -- it functions on ordinary PC equipment. By 1995, Marshall had responded to requests for the package from more than 400 companies in 36 states; some of which reported savings up to $2 million. The National Garment Company of Missouri, for example, uses the system to design and balance a modular line before committing to expensive hardware; for setting up sewing lines; and for determining the composition of a new team.

  1. Green Manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Patten, John

    2013-12-31

    Green Manufacturing Initiative (GMI): The initiative provides a conduit between the university and industry to facilitate cooperative research programs of mutual interest to support green (sustainable) goals and efforts. In addition to the operational savings that greener practices can bring, emerging market demands and governmental regulations are making the move to sustainable manufacturing a necessity for success. The funding supports collaborative activities among universities such as the University of Michigan, Michigan State University and Purdue University and among 40 companies to enhance economic and workforce development and provide the potential of technology transfer. WMU participants in the GMI activities included 20 faculty, over 25 students and many staff from across the College of Engineering and Applied Sciences; the College of Arts and Sciences' departments of Chemistry, Physics, Biology and Geology; the College of Business; the Environmental Research Institute; and the Environmental Studies Program. Many outside organizations also contribute to the GMI's success, including Southwest Michigan First; The Right Place of Grand Rapids, MI; Michigan Department of Environmental Quality; the Michigan Department of Energy, Labor and Economic Growth; and the Michigan Manufacturers Technical Center.

  2. Comparison of accuracies of an intraoral spectrophotometer and conventional visual method for shade matching using two shade guide systems.

    Science.gov (United States)

    Parameswaran, Vidhya; Anilkumar, S; Lylajam, S; Rajesh, C; Narayan, Vivek

    2016-01-01

    This in vitro study compared the shade matching abilities of an intraoral spectrophotometer and the conventional visual method using two shade guides. The results of previous investigations between color perceived by human observers and color assessed by instruments have been inconclusive. The objectives were to determine accuracies and interrater agreement of both methods and effectiveness of two shade guides with either method. In the visual method, 10 examiners with normal color vision matched target control shade tabs taken from the two shade guides (VITAPAN Classical™ and VITAPAN 3D Master™) with other full sets of the respective shade guides. Each tab was matched 3 times to determine repeatability of visual examiners. The spectrophotometric shade matching was performed by two independent examiners using an intraoral spectrophotometer (VITA Easyshade™) with five repetitions for each tab. Results revealed that visual method had greater accuracy than the spectrophotometer. The spectrophotometer; however, exhibited significantly better interrater agreement as compared to the visual method. While VITAPAN Classical shade guide was more accurate with the spectrophotometer, VITAPAN 3D Master shade guide proved better with visual method. This in vitro study clearly delineates the advantages and limitations of both methods. There were significant differences between the methods with the visual method producing more accurate results than the spectrophotometric method. The spectrophotometer showed far better interrater agreement scores irrespective of the shade guide used. Even though visual shade matching is subjective, it is not inferior and should not be underrated. Judicious combination of both techniques is imperative to attain a successful and esthetic outcome.

  3. LEAN Manufacturing

    DEFF Research Database (Denmark)

    Bilberg, Arne

      As part of an employment as Technology Architect at the company Linak in combination with research at the University of Southern Denmark, this paper will present results from a strategy process where Lean has been pointed out as being a very strategic element in the Linak Production System......, organizational and management improvements in the company to what is named the Linak Production System.  ....... The mission with the strategy is to obtain competitive production in Denmark and in Western Europe based on the right combination of manufacturing principles, motivated and trained employees, level of automation, and cooperation with suppliers and customers worldwide. The strategy has resulted in technical...

  4. Satisfaction of Dental Students, Faculty, and Patients with Tooth Shade-Matching Using a Spectrophotometer.

    Science.gov (United States)

    Ballard, Erin; Metz, Michael J; Harris, Bryan T; Metz, Cynthia J; Chou, Jang-Ching; Morton, Dean; Lin, Wei-Shao

    2017-05-01

    The aims of this study were to evaluate dental students' clinical shade-matching outcomes (from subjective use of shade guide) with an objective electronic shade-matching tool (spectrophotometer); to assess patients', students', and supervising faculty members' satisfaction with the clinical shade-matching outcomes; and to assess clinicians' support for use of the spectrophotometer to improve esthetic outcomes. A total of 103 volunteer groups, each consisting of patient, dental student, and supervising faculty member at the University of Louisville, were recruited to participate in the study in 2015. Using the spectrophotometer, clinical shade-matching outcome (ΔE clinical ) and laboratory shade-matching outcome (ΔE laboratory ) were calculated. Two five-point survey items were used to assess the groups' satisfaction with the clinical shade-matching outcome and support for an objective electronic shade-matching tool in the student clinic. The results showed that both ΔE clinical (6.5±2.4) and ΔE laboratory (4.3±2.0) were outside the clinical acceptability threshold ΔE values of 2.7, when visual shade-matching method (subjective usage of shade guide) was used to fabricate definitive restorations. Characteristics of the patients, dental students, supervising faculty members, and restorations had minimal to no effect on the ΔE clinical The patients, dental students, and supervising faculty members generally had positive opinions about the clinical shade-matching outcome, despite the increased ΔE clinical observed. Overall, clinical shade-matching outcomes in this school need further improvement, but the patients' positive opinions may indicate the need to revisit the acceptability threshold ΔE value of 2.7 in the academic setting.

  5. A furnace and temperature controller for optical absorption studies with a spectrophotometer

    International Nuclear Information System (INIS)

    Mariani Rogat, F.

    1975-01-01

    The design and main features of a furnace with a temperature controller and programmer are shown. This system allows to measure the optical absorption spectrum of a sample from room temperature to 400 deg C, in a double beam spectrophotometer Perkin Elmer 350. The sample temperature can be linearly increased at different heating rates between 4 and 38 deg C/min. The temperature ramp can be stopped at any desired point and the sample temperature shall be stabilized in less than one minute. This temperature shall be kept constant within 0.5 deg C for hours. The sample is heated in vacuum. (author)

  6. Monitoring of rain events with a submersible UV/VIS spectrophotometer.

    Science.gov (United States)

    Maribas, Aurélien; Laurent, Nadège; Battaglia, Philippe; do Carmo Lourenço da Silva, Maria; Pons, Marie-Noële; Loison, Bernard

    2008-01-01

    A submersible UV/VIS spectrophotometer has been implemented on the pre-treatment unit of a large-scale wastewater treatment plant (350,000 person-equivalent) to monitor the rapid changes in total Suspended Solids and total Chemical Oxygen Demand occurring during rain events as well as injections of reject water from the sludge treatment train or wasted activated sludge. Calibration has been proven to be difficult for fast composition-varying streams but the device is able to monitor qualitatively sudden quality changes, in spite of the noise affecting the signal. IWA Publishing 2008.

  7. Determining the Absorbance Spectra of Photochromic Materials From Measured Spectrophotometer Data

    Science.gov (United States)

    Downie, John D.

    1998-01-01

    If a two-state photochromic material is optically bleached, the absorbance spectrum data measured by a spectrophotometer is in general comprised of components from both the ground state and the upper state. Under general conditions, it may be difficult to extract the actual upper state spectrum from the spectrum of the bleached material. A simple algorithm is presented here for the recovery of the pure absorbance spectra of the upper state of a material such as bacteriorhodopsin, given single wavelength bleaching illumination, steady-state conditions, and accurate knowledge of phototransition rates and thermal decay rates.

  8. A broad band X-ray imaging spectrophotometer for astrophysical studies

    Science.gov (United States)

    Lum, Kenneth S. K.; Lee, Dong Hwan; Ku, William H.-M.

    1988-01-01

    A broadband X-ray imaging spectrophotometer (BBXRIS) has been built for astrophysical studies. The BBXRIS is based on a large-imaging gas scintillation proportional counter (LIGSPC), a combination of a gas scintillation proportional counter and a multiwire proportional counter, which achieves 8 percent (FWHM) energy resolution and 1.5-mm (FWHM) spatial resolution at 5.9 keV. The LIGSPC can be integrated with a grazing incidence mirror and a coded aperture mask to provide imaging over a broad range of X-ray energies. The results of tests involving the LIGSPC and a coded aperture mask are presented, and possible applications of the BBXRIS are discussed.

  9. Image plane detector spectrophotometer - Application to O2 atmospheric band nightglow

    Science.gov (United States)

    Luo, Mingzhao; Yee, Jeng-Hwa; Hays, Paul B.

    1988-01-01

    A new variety of low resolution spectrometer is described. This device, an image plane detector spectrophotometer, has high sensitivity and modest resolution sufficient to determine the rotational temperature and brightness of molecular band emissions. It uses an interference filter as a dispersive element and a multichannel image plane detector as the photon collecting device. The data analysis technqiue used to recover the temperature of the emitter and the emission brightness is presented. The atmospheric band of molecular oxygen is used to illustrate the use of the device.

  10. Visible light nitrogen dioxide spectrophotometer intercomparison: Mount Kobau, British Columbia, July 28 to August 10, 1991

    Science.gov (United States)

    Mcelroy, C. T.; Elokhov, A. S.; Elansky, N.; Frank, H.; Johnston, P.; Kerr, J. B.

    1994-01-01

    Under the auspices of the World Meteorological Organization, Environment Canada hosted an international comparison of visible light spectrophotometers at Mt. Kobau, British Columbia in August of 1991. Instruments from four countries were involved. The intercomparison results have indicated that some significant differences exist in the responses of the various instruments, and have provided a basis for the comparison of the historical data sets which currently exist as a result of the independent researches carried out in the past in the former Soviet Union, New Zealand, and Canada.

  11. Flight of a UV spectrophotometer aboard Galileo 2, the NASA Convair 990 aircraft

    Science.gov (United States)

    Sellers, B.; Hunderwadel, J. L.; Hanser, F. A.

    1976-01-01

    An ultraviolet interference-filter spectrophotometer (UVS) fabricated for aircraft-borne use on the DOT Climatic Impact Assessment Program (CIAP) has been successfully tested in a series of flights on the NASA Convair 990, Galileo II. UV flux data and the calculated total ozone above the flight path are reported for several of the flights. Good agreement is obtained with the total ozone as deducted by integration of an ozone sonde vertical profile obtained at Wallops Island, Virginia near the time of a CV-990 underpass. Possible advantages of use of the UVS in the NASA Global Atmospheric Sampling Program are discussed.

  12. Optimized manufacturable porous materials

    DEFF Research Database (Denmark)

    Andreassen, Erik; Andreasen, Casper Schousboe; Jensen, Jakob Søndergaard

    to include manufacturing constraints in the optimization. This work focuses on incorporating the manufacturability into the optimization procedure, allowing the resulting material structure to be manufactured directly using rapid manufacturing techniques, such as selective laser melting/sintering (SLM...

  13. White light photothermal lens spectrophotometer for the determination of absorption in scattering samples.

    Science.gov (United States)

    Marcano, Aristides; Alvarado, Salvador; Meng, Junwei; Caballero, Daniel; Moares, Ernesto Marín; Edziah, Raymond

    2014-01-01

    We developed a pump-probe photothermal lens spectrophotometer that uses a broadband arc-lamp and a set of interference filters to provide tunable, nearly monochromatic radiation between 370 and 730 nm as the pump light source. This light is focused onto an absorbing sample, generating a photothermal lens of millimeter dimensions. A highly collimated monochromatic probe light from a low-power He-Ne laser interrogates the generated lens, yielding a photothermal signal proportional to the absorption of light. We measure the absorption spectra of scattering dye solutions using the device. We show that the spectra are not affected by the presence of scattering, confirming that the method only measures the absorption of light that results in generation of heat. By comparing the photothermal spectra with the usual absorption spectra determined using commercial transmission spectrophotometers, we estimate the quantum yield of scattering of the sample. We discuss applications of the device for spectroscopic characterization of samples such as blood and gold nanoparticles that exhibit a complex behavior upon interaction with light.

  14. Non-invasive prediction of hematocrit levels by portable visible and near-infrared spectrophotometer.

    Science.gov (United States)

    Sakudo, Akikazu; Kato, Yukiko Hakariya; Kuratsune, Hirohiko; Ikuta, Kazuyoshi

    2009-10-01

    After blood donation, in some individuals having polycythemia, dehydration causes anemia. Although the hematocrit (Ht) level is closely related to anemia, the current method of measuring Ht is performed after blood drawing. Furthermore, the monitoring of Ht levels contributes to a healthy life. Therefore, a non-invasive test for Ht is warranted for the safe donation of blood and good quality of life. A non-invasive procedure for the prediction of hematocrit levels was developed on the basis of a chemometric analysis of visible and near-infrared (Vis-NIR) spectra of the thumbs using portable spectrophotometer. Transmittance spectra in the 600- to 1100-nm region from thumbs of Japanese volunteers were subjected to a partial least squares regression (PLSR) analysis and leave-out cross-validation to develop chemometric models for predicting Ht levels. Ht levels of masked samples predicted by this model from Vis-NIR spectra provided a coefficient of determination in prediction of 0.6349 with a standard error of prediction of 3.704% and a detection limit in prediction of 17.14%, indicating that the model is applicable for normal and abnormal value in Ht level. These results suggest portable Vis-NIR spectrophotometer to have potential for the non-invasive measurement of Ht levels with a combination of PLSR analysis.

  15. Objectification of facial color inspection to differentiate obstructive/nonobstructive jaundice in neonates by spectrophotometer.

    Science.gov (United States)

    Shen, Zhen; Zheng, Shan; Dong, Rui; Chen, Gong

    2017-12-01

    The purpose of this study was to study whether color difference in facial color truly exists between neonates with obstructive and nonobstructive jaundice, and whether the color difference could be objectified by spectrophotometer. Twelve biliary atresia patients were enrolled in an obstructive jaundice group and 15 neonates admitted for non-conjugated hyperbilirubinemia in a nonobstructive group. Nine patients with syphilis (n=6) and sacrococcygeal teratoma (n=3) were studied as control. Transcutaneous total bilirubin (TB) and hemoglobin were recorded. Face color was measured by spectrophotometer. Spectral reflection curve and L*a*b* model parameters were studied. Facial color of jaundiced neonates were characteristic in waveform that reflectivity at wavelength of 550nm was significantly decreased compared with control by 16.4±3.4%, while not significantly different between obstructive and nonobstructive jaundice (p=0.124). At 650nm, reflection in nonobstructive jaundice was decreased by 8.4±2.3% (pobstructive jaundice (58.09±1.25%)>nonobstructive jaundice (54.25±7.27%). Value b* was higher in jaundiced patients compared to normal control (11.88±2.16, pspectrophotometer. Study of Diagnostic Test. Level II. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Vertical-type chiroptical spectrophotometer (I): instrumentation and application to diffuse reflectance circular dichroism measurement.

    Science.gov (United States)

    Harada, Takunori; Hayakawa, Hiroshi; Kuroda, Reiko

    2008-07-01

    We have designed and built a novel universal chiroptical spectrophotometer (UCS-2: J-800KCMF), which can carry out in situ chirality measurement of solid samples without any pretreatment, in the UV-vis region and with high relative efficiency. The instrument was designed to carry out transmittance and diffuse reflectance (DR) circular dichroism (CD) measurements simultaneously, thus housing two photomultipliers. It has a unique feature that light impinges on samples vertically so that loose powders can be measured by placing them on a flat sample holder in an integrating sphere. As is our first universal chiroptical spectrophotometer, UCS-1, two lock-in amplifiers are installed to remove artifact signals arising from macroscopic anisotropies which are unique to solid samples. High performance was achieved by theoretically analyzing and experimentally proven the effect of the photoelastic modulator position on the CD base line shifts, and by selecting high-quality optical and electric components. Measurement of microcrystallines of both enantiomers of ammonium camphorsulfonate by the DRCD mode gave reasonable results.

  17. Evaluation of Biocompatibility of Root Canal Sealers on L929 Fibroblasts with Multiscan EX Spectrophotometer.

    Science.gov (United States)

    Konjhodzic-Prcic, Alma; Jakupovic, Selma; Hasic-Brankovic, Lajla; Vukovic, Amra

    2015-06-01

    The purpose of the current study was to estimate the biocompatibility of endodontic sealers with different bases on L929 mouse fibroblasts permanent cell line using Multiscan EX Spectrophotometer. Endodontics sealers used in this study were GuttaFlow (Roeko) silicone based sealer, AH plus (De Tray-DENTSPLY) epoxy resin based, Apexit (Vivadent) calcium hydroxide based and Endorez (Ultradent) methacrylate based sealer. Sealer were tested trough time, freshly mixed 24 h, 48h and 7 days after setting. Biocompatibility was determinate on permanent cell lines L929 mouse fibroblasts trough cytotoxicity using MTT assay. Level of absorption was measured with multi scan EX spectrophotometer on length 420-600 nm. Sealer based on calcium hydroxide Apexit Plus, GuttaFlow silicone based sealer and AH plus epoxy resin based sealer, have shown a low cytotoxicity through the all periods of time on culture of L292 mouse fibroblasts. Methacrylate based sealer, Endorez showed moderate cytotoxicity when freshly mixed and after 7 days. After 24 hours the visibility of the cells was 74,0% and after 48 hours 65,1%. which is slightly cytotoxic. According to results of this study there is a statistically significant difference among the groups p<0,05 for all the tested sealers. Apexit Plus, GuttaFlow and AH plus can be considered as biocompatibile. EndoREZ sealer which is based on methacrylate, after 7 days shows 50,1% of visible live cells which is considered as moderate cytotoxicity.

  18. Instrumentation-related uncertainty of reflectance and transmittance measurements with a two-channel spectrophotometer.

    Science.gov (United States)

    Peest, Christian; Schinke, Carsten; Brendel, Rolf; Schmidt, Jan; Bothe, Karsten

    2017-01-01

    Spectrophotometers are operated in numerous fields of science and industry for a variety of applications. In order to provide confidence for the measured data, analyzing the associated uncertainty is valuable. However, the uncertainty of the measurement results is often unknown or reduced to sample-related contributions. In this paper, we describe our approach for the systematic determination of the measurement uncertainty of the commercially available two-channel spectrophotometer Agilent Cary 5000 in accordance with the Guide to the expression of uncertainty in measurements. We focus on the instrumentation-related uncertainty contributions rather than the specific application and thus outline a general procedure which can be adapted for other instruments. Moreover, we discover a systematic signal deviation due to the inertia of the measurement amplifier and develop and apply a correction procedure. Thereby we increase the usable dynamic range of the instrument by more than one order of magnitude. We present methods for the quantification of the uncertainty contributions and combine them into an uncertainty budget for the device.

  19. [Design of flat field holographic concave grating for near-infrared spectrophotometer].

    Science.gov (United States)

    Xiang, Xian-Yi; Wen, Zhi-Yu

    2008-07-01

    Near-infrared spectrum analysis can be used to determine the nature or test quantitatively some chemical compositions by detecting molecular double frequency and multiple frequency absorption. It has been used in agriculture, biology, petrifaction, foodstuff, medicament, spinning and other fields. Near-infrared spectrophotometer is the main apparatus for near-infrared spectrum analysis, and the grating is the most important part of the apparatus. Based on holographic concave grating theory and optic design software CODE V, a flat field holographic concave grating for near-infrared spectrophotometer was designed from primary structure, which relied on global optimization of the software. The contradiction between wide spectrum bound and limited spectrum extension was resolved, aberrations were reduced successfully, spectrum information was utilized fully, and the optic structure of spectrometer was highly efficient. Using CODE V software, complex high-order aberration equations need not be solved, the result can be evaluated quickly, flat field and resolving power can be kept in balance, and the work efficiency is also enhanced. A paradigm of flat field holographic concave grating is given, it works between 900 nm to 1 700 nm, the diameter of the concave grating is 25 mm, and F/ # is 1. 5. The design result was analyzed and evaluated. It was showed that if the slit source, whose width is 50 microm, is used to reconstruction, the theoretic resolution capacity is better than 6.3 nm.

  20. The impact of fit manufacturing on green manufacturing: A review

    Science.gov (United States)

    Qi, Ang Nian; Sin, Tan Chan; Fathullah, M.; Lee, C. C.

    2017-09-01

    Fit manufacturing and Green manufacturing are a new trend principle and concept. They are getting popular in industrial. This paper is identifying the impact between Fit manufacturing and Green manufacturing. Besides Fit manufacturing, Lean manufacturing, Agile manufacturing and Sustainable manufacturing gives big impacts to Green Manufacturing. On top of that, this paper also discuss the benefits of applying Fit manufacturing and Green manufacturing in industrial as well as environment. Hence, applications of Fit manufacturing and Green Manufacturing are increasing year by year.

  1. [Comparison of color reappearance between metal-ceram restoration and foundry-ceram restoration using crystaleye spectrophotometer].

    Science.gov (United States)

    Shi, Tao; Zhang, Ning; Kong, Fan-wen; Zhan, De-song

    2010-10-01

    To study the color reappearance effect of metal-ceram restoration and foundry-ceram restoration using Crystaleye spectrophotometer. 58 metal-ceram restorations and 58 foundry-ceram restorations according to the result of the Crystaleye spectrophotometer were made respectively. The deltaE between restorations and natural teeth as referenced were analyzed. And satisfaction of dentists and patients were evaluated. The deltaE between metal-ceram restorations and natural teeth was 7.13 +/- 0.74. The deltaE between foundry-ceram restorations and teeth was 1.47 +/- 0.84. There were statistical differences between the deltaE (P spectrophotometer can provide accurate reference for foundry-ceram restoration, but for metal-ceram restoration it is not accurate.

  2. Repeatability in Color Measurements of a Spectrophotometer using Different Positioning Devices.

    Science.gov (United States)

    Hemming, Michael; Kwon, So Ran; Qian, Fang

    2015-12-01

    This study aimed to evaluate the repeatability of color measurements of an intraoral spectrophotometer with the use of three different methods by two operators. A total of 60 teeth were obtained, comprising 30 human maxillary teeth [central incisors (n = 10); canines (n = 10); molars (n = 10)] and 30 artificial teeth [lateral incisors (n = 10); premolar (n = 20)]. Multiple repeated color measurements were obtained from each tooth using three measuring methods by each of the two operators. Five typodonts with alternating artificial and human teeth were made. Measurements were taken by two operators with the Vita EasyShade spectrophotometer using the custom tray (CT), custom jig (CJ) and free hand (FH) method, twice, at an interval of 2 to 7 days. Friedman test was used to detect difference among the three color measuring methods. Post hoc Wilcoxon signed-rank test with Bonferroni correction applied was used for pair-wise comparison of color measurements among the three methods. Additionally, a paired-sample t-test was used to assess a significant difference between the two duplicated measurements made on the same tooth by the same operator for each color parameter and measuring method. For operator A, mean (SD) overall color change-ΔE* (SD) perceived for FH, CT and CJ were 2.21(2.00), 2.39 (1.58) and 2.86 (1.92), respectively. There was statistically significant difference in perceived ΔE* in FH vs CJ (p = 0.0107). However, there were no significant differences between FH and CT (p = 0.2829) or between CT and CJ (p = 0.1159). For operator B mean ΔE* (SD) for FH, CT and CJ were 3.24 (3.46), 1.95 (1.19) and 2.45 (1.56), respectively. There was a significant difference between FH and CT (p = 0.0031). However, there were no statistically significant differences in ΔE* in FH vs CJ (p = 0.3696) or CT vs CJ (p = 0.0809). The repeatability of color measurements was different among the three measuring methods by operators. Overall, the CT method worked well for both

  3. [Precision and accuracy of a dental spectrophotometer in gingival color measurement of maxillary anterior gingival].

    Science.gov (United States)

    Du, Yang; Tan, Jian-guo; Chen, Li; Wang, Fang-ping; Tan, Yao; Zhou, Jian-feng

    2012-08-18

    To explore a gingival shade matching method and to evaluate the precision and accuracy of a dental spectrophotometer modified to be used in gingival color measurement. Crystaleye, a dental spectrophotometer (Olympus, Tokyo, Japan) with a custom shading cover was tested. For precision assessment, two experienced experimenters measured anterior maxillary incisors five times for each tooth. A total of 20 healthy gingival sites (attached gingiva, free gingiva and medial gingival papilla in anterior maxillary region) were measured,the Commission Internationale de I' Eclairage (CIE) color parameters (CIE L*a*b*) of which were analyzed using the supporting software. For accuracy assessment, a rectangular area of approximately 3 mm×3 mm was chosen in the attached gingival portion for spectral analysis. PR715 (SpectraScan;Photo Research Inc.,California, USA), a spectroradiometer, was utilized as standard control. Average color differences (ΔE) between the values from PR715 and Crystaleye were calculated. In precision assessment,ΔL* between the values in all the test sites and average values were from(0.28±0.16)to(0.78±0.57), with Δa*and Δb* from(0.28±0.15)to (0.87±0.65),from(0.19±0.09)to( 0.58±0.78), respectively. Average ΔE between values in all test sites and average values were from (0.62 ± 0.17) to (1.25 ± 0.98) CIELAB units, with a total average ΔE(0.90 ± 0.18). In accuracy assessment, ΔL* with control device were from(0.58±0.50)to(2.22±1.89),with Δa*and Δb* from(1.03±0.67)to(2.99±1.32),from(0.68±0.78)to(1.26±0.83), respectively. Average ΔE with the control device were from (2.44±0.82) to (3.51±1.03) CIELAB units, with a total average ΔE (2.96 ± 1.08). With appropriate modification, Crystaleye, the spectrophotometer, has demonstrated relative minor color variations that can be useful in gingival color measurement.

  4. Elemental investigation of momordica charantia linn. and syzigium jambolana linn. using atomic absorption spectrophotometer

    International Nuclear Information System (INIS)

    Kazi, T.G.

    2002-01-01

    Elemental investigation of very important medicinal plant i.e. momordica charantia linn and syzigium jambolana linn, and its decoction has been carried out using flame atomic absorption spectrophotometer. In present study fifteen essential, trace and toxic elements such as Zn, Cr, K, Mg, Ca, Na, Cu, Fe, Pb, Al, Ba, Mn, Co, Ni and Cd were determined in different parts of both plants and in its decoction. The level of essential elements was found high as compared to the level of toxic elements. Both plants are useful in the treatment of diabetes. The validation of the method was checked by employing NBS- 1570 (Spanish) as a standard reference material . The measured values of elements are in close agreement with certified values. (author)

  5. Automated drug dissolution monitor that uses a UV-visible diode array spectrophotometer.

    Science.gov (United States)

    Lo, S C; Donahue, S M; Brown, C W

    1993-04-01

    A method for performing multicomponent analysis in drug dissolution testing without chromatographic separation is presented. Aliquots from dissolution vessels are automatically transferred to a UV-visible diode array spectrophotometer, spectra are measured, and the aliquots are returned to the testing vessels. A full-spectrum calibration method based on principal-component regression is used to simultaneously determine the concentrations of active ingredients and to account for interferences due to excipients in a tablet formulation. The system was evaluated with two commercial pharmaceutical formularies; the first contained pseudoephedrine hydrochloride and chlorpheniramine maleate, whereas the second was a mixture of phenylpropanolamine hydrochloride and chlorpheniramine maleate. The selections of standard mixtures for calibration and validation were based on a factorial design.

  6. A Study of UV Spectral Transmission Through Different Transparent Media with Spectrophotometer

    Directory of Open Access Journals (Sweden)

    R B Gadgil

    1981-01-01

    Full Text Available This experiment was carried out with the help of spectrophotometer using an artificial UV light source to find -out the percentage transmission of UVA and UVB regions of the UV spectrum. The aim of the experiment was to select the transparent medium which would block mum UVB at the same time allowing mammum UVA to pass through thus reducing the unwanted side effects of UVB light and reducing the efficacy of PUVASOL. It was observed that an ordinary plain 3.3 mm colorless glass was the best transparent medium and with its use a simple solarium could be constructed to treat patients on PUVASOL with sunlight as the source of UV light.

  7. Design and evaluation of an imaging spectrophotometer incorporating a uniform light source.

    Science.gov (United States)

    Noble, S D; Brown, R B; Crowe, T G

    2012-03-01

    Accounting for light that is diffusely scattered from a surface is one of the practical challenges in reflectance measurement. Integrating spheres are commonly used for this purpose in point measurements of reflectance and transmittance. This solution is not directly applicable to a spectral imaging application for which diffuse reflectance measurements are desired. In this paper, an imaging spectrophotometer design is presented that employs a uniform light source to provide diffuse illumination. This creates the inverse measurement geometry to the directional illumination/diffuse reflectance mode typically used for point measurements. The final system had a spectral range between 400 and 1000 nm with a 5.2 nm resolution, a field of view of approximately 0.5 m by 0.5 m, and millimeter spatial resolution. Testing results indicate illumination uniformity typically exceeding 95% and reflectance precision better than 1.7%.

  8. Total ozone trends over the USA during 1979-1991 from Dobson spectrophotometer observations

    Science.gov (United States)

    Komhyr, Walter D.; Grass, Robert D.; Koenig, Gloria L.; Quincy, Dorothy M.; Evans, Robert D.; Leonard, R. Kent

    1994-01-01

    Ozone trends for 1979-1991, determined from Dobson spectrophotometer observations made at eight stations in the United States, are augmented with trend data from four foreign cooperative stations operated by NOAA/CMDL. Results are based on provisional data archived routinely throughout the years at the World Ozone Data Center in Toronto, Canada, with calibration corrections applied to some of the data. Trends through 1990 exhibit values of minus 0.3 percent to minus 0.5 percent yr(exp -1) at mid-to-high latitudes in the northern hemisphere. With the addition of 1991 data, however, the trends become less negative, indicating that ozone increased in many parts of the world during 1991. Stations located within the plus or minus 20 deg N-S latitude band exhibit no ozone trends. Early 1992 data show decreased ozone values at some of the stations. At South Pole, Antarctica, October ozone values have remained low during the past 3 years.

  9. Calibration of a laboratory spectrophotometer for specular light by means of stacked glass plates.

    Science.gov (United States)

    Allen, W. A.; Richardson, A. J.

    1971-01-01

    Stacked glass plates have been used to calibrate a laboratory spectrophotometer, over the spectral range 0.5-2.5 microns, for specular light. The uncalibrated instrument was characterized by systematic errors when used to measure the reflectance and transmittance of stacked glass plates. Calibration included first, a determination of the reflectance of a standard composed of barium sulfate paint deposited on an aluminum plate; second, the approximation of the reflectance and transmittance residuals between observed and computed values by means of cubic equations; and, finally, the removal of the systematic errors by a computer. The instrument, after calibration, was accurate to 1% when used to measure the reflectance and transmittance of stacked glass plates.

  10. Lightness, chroma, and hue distributions in natural teeth measured by a spectrophotometer.

    Science.gov (United States)

    Pustina-Krasniqi, Teuta; Shala, Kujtim; Staka, Gloria; Bicaj, Teuta; Ahmedi, Enis; Dula, Linda

    2017-01-01

    The aim of the study was to analyze the distribution of color parameters, lightness (L*), chroma (C), hue (H), a* and b*, in the intercanine sector in maxilla. Patients' tooth color measurements were performed using an intraoral spectrophotometer VITA Easyshade ® (VITA Zahnfabrik H. Rauter GmbH and Co. KG, Bad Sackingen, Germany). The measurements were made in 255 subjects in the intercanine sector in maxilla. The mean values for the group of 255 subjects were as follows: L*, a*, b*, C, and H as 81.6, 0.67, 21.6, 21.7, and 92.7, respectively. For F=206.27 and P < 0.001 between L*, a*, b*, C, H, and central incisor/lateral incisor/canines, there were statistically significant differences. With the statistical analysis, it was determined that there are significant color differences between the teeth of the intercanine sector, which differences are clinically significant also.

  11. Microvolume protein concentration determination using the NanoDrop 2000c spectrophotometer.

    Science.gov (United States)

    Desjardins, Philippe; Hansen, Joel B; Allen, Michael

    2009-11-04

    Traditional spectrophotometry requires placing samples into cuvettes or capillaries. This is often impractical due to the limited sample volumes often used for protein analysis. The Thermo Scientific NanoDrop 2000c Spectrophotometer solves this issue with an innovative sample retention system that holds microvolume samples between two measurement surfaces using the surface tension properties of liquids, enabling the quantification of samples in volumes as low as 0.5-2 microL. The elimination of cuvettes or capillaries allows real time changes in path length, which reduces the measurement time while greatly increasing the dynamic range of protein concentrations that can be measured. The need for dilutions is also eliminated, and preparations for sample quantification are relatively easy as the measurement surfaces can be simply wiped with laboratory wipe. This video article presents modifications to traditional protein concentration determination methods for quantification of microvolume amounts of protein using A280 absorbance readings or the BCA colorimetric assay.

  12. SphinX soft X-ray spectrophotometer: Science objectives, design and performance

    Science.gov (United States)

    Gburek, S.; Sylwester, J.; Kowalinski, M.; Bakala, J.; Kordylewski, Z.; Podgorski, P.; Plocieniak, S.; Siarkowski, M.; Sylwester, B.; Trzebinski, W.; Kuzin, S. V.; Pertsov, A. A.; Kotov, Yu. D.; Farnik, F.; Reale, F.; Phillips, K. J. H.

    2011-06-01

    The goals and construction details of a new design Polish-led X-ray spectrophotometer are described. The instrument is aimed to observe emission from entire solar corona and is placed as a separate block within the Russian TESIS X- and EUV complex aboard the CORONAS-PHOTON solar orbiting observatory. SphinX uses silicon PIN diode detectors for high time resolution measurements of the solar spectra in the range 0.8-15 keV. Its spectral resolution allows for discerning more than hundred separate energy bands in this range. The instrument dynamic range extends two orders of magnitude below and above these representative for GOES. The relative and absolute accuracy of spectral measurements is expected to be better than few percent, as follows from extensive ground laboratory calibrations.

  13. Demonstrating Principles of Spectrophotometry by Constructing a Simple, Low-Cost, Functional Spectrophotometer Utilizing the Light Sensor on a Smartphone

    Science.gov (United States)

    Hosker, Bill S.

    2018-01-01

    A highly simplified variation on the do-it-yourself spectrophotometer using a smartphone's light sensor as a detector and an app to calculate and display absorbance values was constructed and tested. This simple version requires no need for electronic components or postmeasurement spectral analysis. Calibration graphs constructed from two…

  14. Development of a low-cost NIR instrument for minced meat analysis: Part 1 - Spectrophotometer and sample presentations

    Science.gov (United States)

    The feasibility of using a compact, low-cost NIR spectrophotometer to predict moisture (MC) and total fat content of minced pork was demonstrated. Results were compared with those obtained using two research type instruments with high signal to noise ratio (S/N). The NIR measuring head of the compac...

  15. Photochemical induced growth and aggregation of metal nanoparticles in diode-array spectrophotometer via excited dimethyl-sulfoxide.

    Science.gov (United States)

    Zidki, Tomer; Cohen, Haim; Meyerstein, Dan

    2010-10-21

    Ag(0) and Au(0) nanoparticles suspended in dilute aqueous solutions containing (CH(3))(2)SO are photochemically unstable. The light source of a diode-array spectrophotometer induces, within less than a minute, particle growth and aggregation. The results indicate that this process is triggered by UV light absorption by the (CH(3))(2)SO.

  16. A low cost short wave near infrared spectrophotometer: application for determination of quality parameters of diesel fuel.

    Science.gov (United States)

    Gonzaga, Fabiano Barbieri; Pasquini, Celio

    2010-06-18

    A low cost absorption spectrophotometer for the short wave near infrared spectral region (850-1050 nm) is described. The spectrophotometer is basically composed of a conventional dichroic lamp, a long-pass filter, a sample cell and a Czerny-Turner type polychromator coupled to a 1024 pixel non-cooled photodiode array. A preliminary evaluation of the spectrophotometer showed good repeatability of the first derivative of the spectra at a constant room temperature and the possibility of assigning some spectral regions to different C-H stretching third overtones. Finally, the spectrophotometer was successfully applied for the analysis of diesel samples and the determination of some of their quality parameters using partial least squares calibration models. The values found for the root mean square error of prediction using external validation were 0.5 for the cetane index and from 2.5 to 5.0 degrees C for the temperatures achieved during distillation when obtaining 10, 50, 85, and 90% (v/v) of the distilled sample, respectively. 2010 Elsevier B.V. All rights reserved.

  17. Assessing the Engagement, Learning, and Overall Experience of Students Operating an Atomic Absorption Spectrophotometer with Remote Access Technology

    Science.gov (United States)

    Erasmus, Daniel J.; Brewer, Sharon E.; Cinel, Bruno

    2015-01-01

    The use of internet-based technologies in the teaching of laboratories has emerged as a promising education tool. This study evaluated the effectiveness of using remote access technology to operate an atomic absorption spectrophotometer in analyzing the iron content in a crude myoglobin extract. Sixty-two students were surveyed on their level of…

  18. Manufacturing network evolution

    DEFF Research Database (Denmark)

    Yang, Cheng; Farooq, Sami; Johansen, John

    2011-01-01

    Purpose – This paper examines the effect of changes at the manufacturing plant level on other plants in the manufacturing network and also investigates the role of manufacturing plants on the evolution of a manufacturing network. Design/methodology/approach –The research questions are developed......, the complex phenomenon of a manufacturing network evolution is observed by combining the analysis of a manufacturing plant and network level. The historical trajectories of manufacturing networks that are presented in the case studies are examined in order to understand and determine the future shape...

  19. Determination of mercury by cold vapor atomic absorption spectrophotometer in Tongkat Ali preparations obtained in Malaysia.

    Science.gov (United States)

    Ang, Hooi-Hoon; Lee, Ee-Lin; Cheang, Hui-Seong

    2004-01-01

    The DCA (Drug Control Authority), Malaysia, has implemented the phase 3 registration of traditional medicines on 1 January 1992, with special emphasis on the quality, efficacy, and safety (including the presence of heavy metals) in all pharmaceutical dosage forms of traditional medicine preparations. As such, a total of 100 products in various pharmaceutical dosage forms of a herbal preparation, containing Tongkat Ali, were analyzed for mercury content using cold vapor atomic absorption spectrophotometer. Results showed that 36% of the above products possessed 0.52 to 5.30 ppm of mercury and, therefore, do not comply with the quality requirement for traditional medicines in Malaysia. Out of these 36 products, 5 products that possessed 1.05 to 4.41 ppm of mercury were in fact have already registered with the DCA, Malaysia. However, the rest of the products that contain 0.52 to 5.30 ppm of mercury still have not registered with the DCA, Malaysia. Although this study showed that only 64% of the products complied with the quality requirement for traditional medicines in Malaysia pertaining to mercury, they cannot be assumed safe from mercury contamination because of batch-to-batch inconsistency.

  20. Design and testing of a new high-accuracy ultraviolet-visible-near-infrared spectrophotometer.

    Science.gov (United States)

    Zwinkels, J C; Gignac, D S

    1992-04-01

    A new high-accuracy spectrophotometer has been developed at the National Research Council of Canada to measure regular transmittance factors over the spectral range from 200 to 2500 nm. The most significant feature of this automated single-beam instrument is a highly collimated normal-incidence beam geometry, which eliminates the need for polarization corrections or for an averaging sphere for the calibration of regular-transmittance reference materials. The instrument also possesses a large uniformmeasurement beam that minimizes errors caused by sample nonuniformity. We describe the instrument's design and the testing, optimization, and verification procedures that have been carried out for measurements in the visible and near-infrared regions. Systematic errors that have been determined and corrected for include wavelength shifts, stray light, system drift, and nonlinearity. In the visible and near-infrared regions, the overall photometric accuracy is estimated to be 2.5 and 4.0 parts in 10(4), respectively. The wavelength scale is accurate to within +/-0.1 nm with a reproducibility of +/-0.03 nm over its entire design range from 200 to 2500 nm.

  1. Optofluidic UV-Vis spectrophotometer for online monitoring of photocatalytic reactions.

    Science.gov (United States)

    Wang, Ning; Tan, Furui; Zhao, Yu; Tsoi, Chi Chung; Fan, Xudong; Yu, Weixing; Zhang, Xuming

    2016-06-29

    On-chip integration of optical detection units into the microfluidic systems for online monitoring is highly desirable for many applications and is also well in line with the spirit of optofluidics technology-fusion of optics and microfluidics for advanced functionalities. This paper reports the construction of a UV-Vis spectrophotometer on a microreactor, and demonstrates the online monitoring of the photocatalytic degradations of methylene blue and methyl orange under different flow rates and different pH values by detecting the intensity change and/or the peak shift. The integrated device consists of a TiO2-coated glass substrate, a PDMS micro-sized reaction chamber and two flow cells. By comparing with the results of commercial equipment, we have found that the measuring range and the sensitivity are acceptable, especially when the transmittance is in the range of 0.01-0.9. This integrated optofluidic device can significantly cut down the test time and the sample volume, and would provide a versatile platform for real-time characterization of photochemical performance. Moreover, its online monitoring capability may enable to access the usually hidden information in biochemical reactions like intermediate products, time-dependent processes and reaction kinetics.

  2. A study of a sector spectrophotometer and auroral O+(2P-2D) emissions

    Science.gov (United States)

    Swenson, G. R.

    1976-01-01

    The metastable O+(2P-2D) auroral emission was investigated. The neighboring OH contaminants and low intensity levels of the emission itself necessitated the evolution of an instrument capable of separating the emission from the contaminants and having a high sensitivity in the wavelength region of interest. A new type of scanning photometer was developed and its properties are discussed. The theoretical aspects of auroral electron interaction with atomic oxygen and the resultant O+(2P-2D) emissions were examined in conjunction with N2(+)1NEG emissions. Ground based measurements of O+(2P-2D) auroral emission intensities were made using the spatial scanning photometer (sector spectrophotometer). Simultaneous measurements of N2(+)1NEG sub 1,0 emission intensity were made in the same field of view using a tilting photometer. Time histories of the ratio of these two emissions made in the magnetic zenith during auroral breakup periods are given. Theories of I sub 7319/I sub 4278 of previous investigators were presented. A rocket measurement of N2(+)1NEG sub 0,0 and O+(2P-2D) emission in aurora was examined in detail and was found to agree with the ground based measurements. Theoretical examination resulted in the deduction of the electron impact efficiency generating O+(2P) and also suggests a large source of O+(2P) at low altitude. A possible source is charge exchange of N+(1S) with OI(3P).

  3. Outdoor solar UVA dose assessment with EBT2 radiochromic film using spectrophotometer and densitometer measurements.

    Science.gov (United States)

    Abukassem, I; Bero, M A

    2015-04-01

    Direct measurements of solar ultraviolet radiations (UVRs) have an important role in the protection of humans against UVR hazard. This work presents simple technique based on the application of EBT2 GAFCHROMIC(®) film for direct solar UVA dose assessment. It demonstrates the effects of different parts of the solar spectrum (UVB, visible and infrared) on performed UVA field measurements and presents the measurement uncertainty budget. The gradient of sunlight exposure level permitted the authors to establish the mathematical relationships between the measured solar UVA dose and two measured quantities: the first was the changes in spectral absorbance at the wavelength 633 nm (A633) and the second was the optical density (OD). The established standard relations were also applied to calculate the solar UVA dose variations during the whole day; 15 min of exposure each hour between 8:00 and 17:00 was recorded. Results show that both applied experimental methods, spectrophotometer absorbance and densitometer OD, deliver comparable figures for EBT2 solar UVA dose assessment with relative uncertainty of 11% for spectral absorbance measurements and 15% for OD measurements. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. A double-beam rapid-scanning stopped-flow spectrophotometer.

    Science.gov (United States)

    Holloway, M R; White, H A

    1975-01-01

    A double-beam rapid-wavelength-scanning stopped-flow spectrophotometer system based on the Norcon model 501 spectrometer was construced, which enables u.v.-or visible absorbance spectra to be recorded at the rate of 800/s after the rapid mixing (within 3ms) of two reactant solutions. Each spectrum spans about 200nm in 1ms. It is possible to record difference spectra during reactions with half-lives less than 10ms involving absorbance changes of less than 0.1 absorbance unit. Analogue circuitry is used to produce spectra of absorbance against wavelength. Up to 32 such spectra can be recorded at pre-selected times during a reaction and stored in an 8Kx8-bit-word hard-wired data-capture system to be subsequently displaned individually or simultaneously. Time-courses at different wavelengths can also be displayed. By averaging up to 216 spectra it is possible to record spectra under conditions of low signal-to-noise ratios... Images Fig. 3. Fig. 9. PMID:172069

  5. Sensitive determination of mercury by a miniaturized spectrophotometer after in situ single-drop microextraction.

    Science.gov (United States)

    Yang, Fangwen; Liu, Rui; Tan, Zhiqiang; Wen, Xiaodong; Zheng, Chengbin; Lv, Yi

    2010-11-15

    An in situ single-drop microextraction (SDME) method was developed for trace mercury determination by a miniaturized spectrophotometer, in which a simple and cheap light-emitting diode (LED) was employed as the light source, and a handheld charge coupled device (CCD) was served as the detector. A droplet of 0.006% dithizone-CCl(4) (m/v) was used as extraction phase and hanged on a rolled PTFE tube. LED light was adjusted carefully to pass through the centre of the droplet and the entrance slit of the CCD detector. The radiation intensities of 475 nm before and after SDME (I(0) and I(i)) were recorded for quantification. Under the optimum conditions, the system provided a linear range of 2-50 μg L(-1), with a correlation coefficient of 0.9983 and a limit of detection (3σ) of 0.2 μg L(-1). The enrichment factor was about 69. The present method showed the merits of high sensitivity, simplicity, rapidity, low reagent consumption and field analysis potential. Finally, this method was successfully applied for the determination of the total mercury in spiked tap water sample, spiked river water sample and certified reference material (GBW (E) 080393, simulated water). Copyright © 2010 Elsevier B.V. All rights reserved.

  6. Determination of nanomolar chromate in drinking water with solid phase extraction and a portable spectrophotometer.

    Science.gov (United States)

    Ma, Jian; Yang, Bo; Byrne, Robert H

    2012-06-15

    Determination of chromate at low concentration levels in drinking water is an important analytical objective for both human health and environmental science. Here we report the use of solid phase extraction (SPE) in combination with a custom-made portable light-emitting diode (LED) spectrophotometer to achieve detection of chromate in the field at nanomolar levels. The measurement chemistry is based on a highly selective reaction between 1,5-diphenylcarbazide (DPC) and chromate under acidic conditions. The Cr-DPC complex formed in the reaction can be extracted on a commercial C18 SPE cartridge. Concentrated Cr-DPC is subsequently eluted with methanol and detected by spectrophotometry. Optimization of analytical conditions involved investigation of reagent compositions and concentrations, eluent type, flow rate (sample loading), sample volume, and stability of the SPE cartridge. Under optimized conditions, detection limits are on the order of 3 nM. Only 50 mL of sample is required for an analysis, and total analysis time is around 10 min. The targeted analytical range of 0-500 nM can be easily extended by changing the sample volume. Compared to previous SPE-based spectrophotometric methods, this analytical procedure offers the benefits of improved sensitivity, reduced sample consumption, shorter analysis time, greater operational convenience, and lower cost. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. [Determination of soil exchangeable base cations by using atomic absorption spectrophotometer and extraction with ammonium acetate].

    Science.gov (United States)

    Zhang, Yu-ge; Xiao, Min; Dong, Yi-hua; Jiang, Yong

    2012-08-01

    A method to determine soil exchangeable calcium (Ca), magnesium (Mg), potassium (K), and sodium (Na) by using atomic absorption spectrophotometer (AAS) and extraction with ammonium acetate was developed. Results showed that the accuracy of exchangeable base cation data with AAS method fits well with the national standard referential soil data. The relative errors for parallel samples of exchangeable Ca and Mg with 66 pair samples ranged from 0.02%-3.14% and 0.06%-4.06%, and averaged to be 1.22% and 1.25%, respectively. The relative errors for exchangeable K and Na with AAS and flame photometer (FP) ranged from 0.06%-8.39% and 0.06-1.54, and averaged to be 3.72% and 0.56%, respectively. A case study showed that the determination method for exchangeable base cations by using AAS was proven to be reliable and trustable, which could reflect the real situation of soil cation exchange properties in farmlands.

  8. Analysis of ozone observation at atmospheric monitoring network station using Brewer ozone spectrophotometer

    Science.gov (United States)

    Tan, Kok Chooi; Tan, Mou Leong; Lim, Hwee San; Mat Jafri, Mohamad Zubir

    2017-10-01

    Ozone (O3) is unique among pollutants because it is not emitted directly into the air, and its results from complex chemical reactions in the atmosphere. O3 can bring different effects for all the living on earth (either harm or protect), depending on where O3 resides. This is the main reason why O3 is such a serious environmental problem that is difficult to control and predict. The objective of this paper is to analyze the variations of total column O3 measured by Brewer O3 spectrophotometer over Global Atmosphere Watch Station (GAW) regional station, which is located at southwest of Peninsular Malaysia, Petaling Jaya. Total column O3 observations in Petaling Jaya are studied for the period January 2008 to December 2008. Ozone shows seasonal variation with maximum (276.8 DU in May 2008) during pre-monsoon season and minimum (246.8 DU in January 2008) during northeast monsoon season. In addition, the monthly O3 maps for the year of 2008 were obtained from the NASA-operated Giovanni portal to overview the distribution of total column O3 in Peninsular Malaysia. For the upcoming studies, validation of ground measurements with satellite O3 data and study of tropospheric O3 over the study area is recommended.

  9. Sensitive determination of mercury by a miniaturized spectrophotometer after in situ single-drop microextraction

    International Nuclear Information System (INIS)

    Yang Fangwen; Liu Rui; Tan Zhiqiang; Wen Xiaodong; Zheng Chengbin; Lv Yi

    2010-01-01

    An in situ single-drop microextraction (SDME) method was developed for trace mercury determination by a miniaturized spectrophotometer, in which a simple and cheap light-emitting diode (LED) was employed as the light source, and a handheld charge coupled device (CCD) was served as the detector. A droplet of 0.006% dithizone-CCl 4 (m/v) was used as extraction phase and hanged on a rolled PTFE tube. LED light was adjusted carefully to pass through the centre of the droplet and the entrance slit of the CCD detector. The radiation intensities of 475 nm before and after SDME (I 0 and I i ) were recorded for quantification. Under the optimum conditions, the system provided a linear range of 2-50 μg L -1 , with a correlation coefficient of 0.9983 and a limit of detection (3σ) of 0.2 μg L -1 . The enrichment factor was about 69. The present method showed the merits of high sensitivity, simplicity, rapidity, low reagent consumption and field analysis potential. Finally, this method was successfully applied for the determination of the total mercury in spiked tap water sample, spiked river water sample and certified reference material (GBW (E) 080393, simulated water).

  10. The Soft X-ray Spectrophotometer SphinX for the CORONAS-Photon Mission

    Science.gov (United States)

    Sylwester, Janusz; Kowalinski, Miroslaw; Szymon, Gburek; Bakala, Jaroslaw; Kuzin, Sergey; Kotov, Yury; Farnik, Frantisek; Reale, Fabio

    The purpose, construction details and calibration results of the new design, Polish-led solar X-ray spectrophotometer SphinX will be presented. The instrument constitutes a part of the Russian TESIS X-ray and EUV complex aboard the forthcoming CORONAS-Photon solar mission to be launched later in 2008. SphinX uses Si-PIN detectors for high time resolution (down to 0.01 s) measurements of solar spectra in the energy range between 0.5 keV and 15 keV. The spectral resolution allows separating 256 individual energy channels in this range with particular groups of lines clearly distinguishable. Unprecedented accuracy of the instrument calibration at the XACT (Palermo) and BESSY (Berlin) synchrotron will allow for establishing the solar soft X-ray photometric reference system. The cross-comparison between SphinX and the other instruments presently in orbit like XRT on Hinode, RHESSI and GOES X-ray monitor, will allow for a precise determination of the coronal emission measure and temperature during both very low and very high activity periods. Examples of the detectors' ground calibration results as well as the calculated synthetic spectra will be presented. The operation of the instrument while in orbit will be discussed allowing for suggestions from other groups to be still included in mission planning.

  11. Validation of the method spectrophotometer in the histamine determination in fresh tuna (Thunnus Tunna)

    International Nuclear Information System (INIS)

    Chacon Silva, F.

    1998-01-01

    The objective of this study was to validate the spectrophotometer method described by Bateman et al. (1994) for the histamine determination in fresh tuna (Thunnus Tunna) and to evaluate the histamine concentration in samples of fresh tuna. To fulfill the recently exposed objectives, the figures of merit were determined like they are it: recovery limits of detection, sensibility and repetitive of the method spectrophotometry and applied the analysis at twenty samples of fresh tuna for copy of the Metropolitan area and three sample like reference of fresh tuna stored 4 degree centigrade by 15 days. The histamine recovery you determines enriching seven ours of fresh tuna with histamine to two levels different 0.613 mg/L and 2.21 mg/L. three samples were left without enriching and you subtract the average to the native histamine. You determines the one it limits of detection using the standard deviation to three levels of concentration of histamine 1.37 mg/L, 2.22 mg/L and 3.22 mg/L, the minimum quantity of hi stamina that you can determine for the method spectrophotometry settling down. The repetitive you determines using the standard deviation for 100 among the average of the histamine values, in seven you replies independent of the same sample. You determines the histamine content, in the fresh tuna Thunnus Tunna of the expends of the Metropolitan Area and in samples of reference stored 4 degrees centigrade by 15 days [es

  12. Strategic Roles of Manufacturing

    DEFF Research Database (Denmark)

    Yang, Cheng

    Addressing three development trends of manufacturing, this thesis aims to explore: (1) facing challenges on manufacturing (globalisation, knowledge-based manufacturing and servitisation of manufacturing), what kinds of roles does manufacturing play within industrial companies; (2) along with the ......Addressing three development trends of manufacturing, this thesis aims to explore: (1) facing challenges on manufacturing (globalisation, knowledge-based manufacturing and servitisation of manufacturing), what kinds of roles does manufacturing play within industrial companies; (2) along...... with the trend of globalisation, how do industrial companies develop their global manufacturing networks? These two questions are actually interlinked. On the one hand, facing increasing offshoring and outsourcing of production activities, industrial companies have to understand how to develop their global...... manufacturing networks. On the other hand, ongoing globalisation also brings tremendous impacts to post-industrial economies (e.g. Denmark). A dilemma therefore arises, i.e. whether it is still necessary to keep manufacturing in these post-industrial economies; if yes, what kinds of roles manufacturing should...

  13. Gluing interface qualification test results and gluing process development of the EUCLID near-infrared spectro-photometer optical assembly

    Science.gov (United States)

    Mottaghibonab, A.; Thiele, H.; Gubbini, E.; Dubowy, M.; Gal, C.; Mecsaci, A.; Gawlik, K.; Vongehr, M.; Grupp, F.; Penka, D.; Wimmer, C.; Bender, R.

    2016-07-01

    The Near Infrared Spectro-Photometer Optical assembly (NIOA) of EUCLID satellite requires high precision large lens holders with different lens materials, shapes and diameters. The aspherical lenses are glued into their separate CTE matched lens holder. The gluing of the lenses in their holder with 2K epoxy is selected as bonding process to minimize the stress in the lenses to achieve the required surface form error (SFE) performance (32nm) and lens position stability (+/-10μm) due to glue shrinkage. Adhesive shrinkage stress occurs during the glue curing at room temperature and operation in cryogenic temperatures, which might overstress the lens, cause performance loss, lens breakage or failure of the gluing interface. The selection of the suitable glue and required bonding parameters, design and qualification of the gluing interface, development and verification of the gluing process was a great challenge because of the low TRL and heritage of the bonding technology. The different material combinations (CaF2 to SS316L, LF5G15 and S-FTM16 to Titanium, SUPRASIL3001 to Invar M93), large diameter (168mm) and thin edge of the lenses, cryogenic nonoperational temperature (100K) and high performance accuracy of the lenses were the main design driver of the development. The different coefficients of thermal expansion (CTE) between lens and lens holder produce large local mechanical stress. As hygroscopic crystal calcium fluoride (CaF2) is very sensitive to moisture therefore an additional surface treatment of the gluing area is necessary. Extensive tests e.g glue handling and single lap shear tests are performed to select the suitable adhesive. Interface connection tests are performed to verify the feasibility of selected design (double pad design), injection channel, the roughness and treatment of the metal and lens interfaces, glue thickness, glue pad diameter and the gluing process. CTE and dynamic measurements of the glue, thermal cycling, damp- heat, connection

  14. Comparing predictive abilities of three visible-near infrared spectrophotometers for soil organic carbon and clay determination

    DEFF Research Database (Denmark)

    Knadel, Maria; Stenberg, Bo; Deng, Fan

    2013-01-01

    for SOC and clay predictions. The application of different spectral preprocessing procedures did not generate important improvements of the calibration models either. The results from this study showed that as long as strict laboratory scanning protocols were followed no significant differences...... carbon (SOC) and clay calibrations for 194 Danish top soils. Scanning procedures for the three spectrophotometers where done according to uniform laboratory protocols. SOC and clay calibrations were performed using PLS regression. One third of the data was used as an independent test set. A range...... of spectral preprocessing methods was applied in search for model improvement. Validation for SOC content using an independent data set derived from all three spectrophotometers provided values of RMSEP between 0.45 and 0.52 %, R2=0.44-0.58 and RPD=1.3-1.5. Clay content was predicted with a higher precision...

  15. Application of SnO2 nanoparticle as sulfide gas sensor using UV/VIS/NIR spectrophotometer

    Science.gov (United States)

    Juliasih, N.; Buchari; Noviandri, I.

    2017-04-01

    Sulfide gas monitoring is required to protect organisms from its toxicity. Nanoparticles of metal oxides have characteristics that applicable as sensors for controlling environmental pollution like sulfide gas. Thin film of SnO2 as one part of the sulfide gas sensor was synthesized with the chemical liquid deposition method, and characterized by UV/VIS/NIR-Spectrophotometer before and after gas application, also using FTIR, SEM and XRD. Characterization studies showed nanoparticle sizes from the diameters range of 38-71 nm. Application of SnO2 thin film to sulfide gas detected by UV/VIS/NIR Spectrophotometer with diffuse reflectance showed chemical reaction by the shifting of maximum % R peak at wavelength of 1428 cm. The benefit of measurement of sulfide gas using this SnO2 nano thin film is that it could be done at the room temperature.

  16. Determination of the colorants in a beverage sample by chemometrıc methods using an ultraviolet spectrophotometer

    OpenAIRE

    Pekcan Ertokuş, Güzide

    2018-01-01

    In this study, color materials in powdered beverage samples weredetermined by chemometric methods using and UV/VIS spectrophotometer. From thechemometric methods, the principal component regression  (PCR) and the partial least squares method(PLS) were successfully applied in the determination of the amount of sunsetyellow and β-carotene contained in a powdered beverage. The results obtainedwith the help ofapplied chemometric methods are extremely fast, simple and reliable results.

  17. Roughened glass slides and a spectrophotometer for the detection of the wavelength-dependent refractive index of transparent liquids.

    Science.gov (United States)

    Niskanen, Ilpo; Räty, Jukka; Myllylä, Risto; Sutinen, Veijo; Matsuda, Kiyofumi; Homma, Kazuhiro; Silfsten, Pertti; Peiponen, Kai-Erik

    2012-07-01

    We describe a method to determine the wavelength-dependent refractive index of liquids by measurement of light transmittance with a spectrophotometer. The method is based on using roughened glass slides with different a priori known refractive indices and immersing the slides into the transparent liquid with unknown refractive index. Using the dispersion data on the glass material it is possible to find the index match between the liquid and the glass slide, and hence the refractive index of the liquid.

  18. Comparison of accuracies of an intraoral spectrophotometer and conventional visual method for shade matching using two shade guide systems

    Directory of Open Access Journals (Sweden)

    Vidhya Parameswaran

    2016-01-01

    Conclusion: This in vitro study clearly delineates the advantages and limitations of both methods. There were significant differences between the methods with the visual method producing more accurate results than the spectrophotometric method. The spectrophotometer showed far better interrater agreement scores irrespective of the shade guide used. Even though visual shade matching is subjective, it is not inferior and should not be underrated. Judicious combination of both techniques is imperative to attain a successful and esthetic outcome.

  19. Appraising manufacturing location

    NARCIS (Netherlands)

    Steenhuis, H.J.; de Bruijn, E.J.

    2002-01-01

    International location of manufacturing activities is an issue for managers of manufacturing companies as well as public policy makers. For managers, the issue is relevant because international locations offer opportunities for lowering costs due to productivity improvements. For governments the

  20. Measurement of breast milk intake using deuterium oxide and fourier transformed infrared spectrophotometer - a pilot study

    International Nuclear Information System (INIS)

    Adom, T.; Bansa, D.; Boatin, R.; Vuore, T.; Datohe, D.; Timpo, S.; Asamoa-Tutu, P.

    2011-01-01

    The measurement of breast milk intake of infants is essential to the estimation of nutrient requirements during infancy and lactation. The conventional method, test-weighing procedure for measuring breast milk is time consuming, most often inaccurate and may interfere with the mother's normal activities. A more practical and accurate method is isotope dilution using stable isotope-labelled water. The accuracy and ready availability of deuterium oxide (D 2 O) have led to its extensive use in measuring body composition and breast milk intake of infants. The D 2 O turnover method was field-tested in 13 lactating Ghanaian mother-baby pairs. Maternal and baby anthropometric measurements were made. Baby milk intake and maternal body composition were measured with the dose-to-mother method. Pre-dose samples of saliva were taken from each mother-baby pair. A measured D 2 O dose (30g) was administered orally to the mother. Post-dose saliva samples were collected from mother and baby on days 1, 2, 3, 4, 13, and 14. Samples were analysed using Fourier Transformed Infrared Spectrophotometer (FTIR). The mean ± SD maternal age was 24 ± 5 years. Babies were aged 3.5 months on the average and weighed 6.7 ± 0.7 kg. Mean milk intake of babies was 828 ± 132 ml/day with a range of 610 to 1040 ml/day. Maternal fat free mass and % body fat were 44.8 ± 5.3 kg, 23.1 ± 5.1 respectively. This non-invasive and convenient method has been used successfully to measure breast milk intake of Ghanaian infants. (au)

  1. Non-destructive assessment of grapevine water status in the field using a portable NIR spectrophotometer.

    Science.gov (United States)

    Tardaguila, Javier; Fernández-Novales, Juan; Gutiérrez, Salvador; Diago, Maria Paz

    2017-08-01

    Until now, the majority of methods employed to assess grapevine water status have been destructive, time-intensive, costly and provide information of a limited number of samples, thus the ability of revealing within-field water status variability is reduced. The goal of this work was to evaluate the capability of non-invasive, portable near infrared (NIR) spectroscopy acquired in the field, to assess the grapevine water status in diverse varieties, grown under different environmental conditions, in a fast and reliable way. The research was conducted 2 weeks before harvest in 2012, in two commercial vineyards, planted with eight different varieties. Spectral measurements were acquired in the field on the adaxial and abaxial sides of 160 individual leaves (20 leaves per variety) using a commercially available handheld spectrophotometer (1600-2400 nm). Principal component analysis (PCA) and modified partial least squares (MPLS) were used to interpret the spectra and to develop reliable prediction models for stem water potential (Ψ s ) (cross-validation correlation coefficient (r cv ) ranged from 0.77 to 0.93, and standard error of cross validation (SECV) ranged from 0.10 to 0.23), and leaf relative water content (RWC) (r cv ranged from 0.66 to 0.81, and SECV between 1.93 and 3.20). The performance differences between models built from abaxial and adaxial-acquired spectra is also discussed. The capability of non-invasive NIR spectroscopy to reliably assess the grapevine water status under field conditions was proved. This technique can be a suitable and promising tool to appraise within-field variability of plant water status, helpful to define optimised irrigation strategies in the wine industry. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  2. Comparison of Ozone Retrievals from the Pandora Spectrometer System and Dobson Spectrophotometer in Boulder, Colorado

    Science.gov (United States)

    Herman, J.; Evans, R.; Cede, A.; Abuhassan, N.; Petropavlovskikh, I.; McConville, G.

    2015-01-01

    A comparison of retrieved total column ozone (TCO) amounts between the Pandora #34 spectrometer system and the Dobson #061 spectrophotometer from direct-sun observations was performed on the roof of the Boulder, Colorado, NOAA building. This paper, part of an ongoing study, covers a 1-year period starting on 17 December 2013. Both the standard Dobson and Pandora TCO retrievals required a correction, TCO(sub corr) = TCO (1 + C(T)), using a monthly varying effective ozone temperature, T(sub E), derived from a temperature and ozone profile climatology. The correction is used to remove a seasonal difference caused by using a fixed temperature in each retrieval algorithm. The respective corrections C(T(sub E)) are C(sub Pandora) = 0.00333(T(sub E) - 225) and C(sub Dobson) = -0.0013(T(sub E) - 226.7) per degree K. After the applied corrections removed most of the seasonal retrieval dependence on ozone temperature, TCO agreement between the instruments was within 1% for clear-sky conditions. For clear-sky observations, both co-located instruments tracked the day-to-day variation in total column ozone amounts with a correlation of r(exp 2) = 0.97 and an average offset of 1.1 +/- 5.8 DU. In addition, the Pandora TCO data showed 0.3% annual average agreement with satellite overpass data from AURA/OMI (Ozone Monitoring Instrument) and 1% annual average offset with Suomi-NPP/OMPS (Suomi National Polar-orbiting Partnership, the nadir viewing portion of the Ozone Mapper Profiler Suite).

  3. Comparison of Shade of Ceramic with Three Different Zirconia Substructures using Spectrophotometer.

    Science.gov (United States)

    Habib, Syed Rashid; Shiddi, Ibraheem F Al

    2015-02-01

    This study assessed how changing the Zirconia (Zr) substructure affected the color samples after they have been overlaid by the same shade of veneering ceramic. Three commercial Zr materials were tested in this study: Prettau(®) Zirconia (ZirKonZahn, Italy), Cercon (Dentsply, Germany) and InCoris ZI (Sirona, Germany). For each system, 15 disk-shaped specimens (10 × 1 mm) were fabricated. Three shades of A1, A2 and A3.5 of porcelain (IPS e.MaxCeram, IvoclarVivadent, USA) were used for layering the specimens. Five specimens from each type of Zr were layered with same shade of ceramic. Color measurements were recorderd by a spectrophotometer Color-Eye(®) 7000A (X-Rite, Grand Rapids, MI). Mean values of L, a, b color coordinates and ΔE were recorded and comparisons were made. Differences in the ΔE were recorded for the same porcelain shade with different Zr substructures and affected the color of the specimens (p < 0.01, ANOVA). The maximum difference between the ΔE values for the A1, A2 and A3.5 shades with three types of Zr substructures was found to be 1.59, 1.69 and 1.45 respectively. Multiple comparisons of the ΔE with PostHoc Tukey test revealed a statistically significant difference (p < 0.05) between the three types of Zr, except between Type 2 Zr and Type 3 Zr for the Shade A1. The mean values of L, a, b and ΔE for the Prettau(®) Zirconia substructure were found to be the least among the three types. The brand of Zr used influences the final color of the all ceramic Zr based restorations and this has clinical significance.

  4. Comparison between Brewer spectrometer, M 124 filter ozonometer and Dobson spectrophotometer

    Science.gov (United States)

    Feister, U.

    1994-01-01

    Concurrent measurements were taken using the Brewer spectrometer no. 30, the filter ozonometer M 124 no. 200 and the Dobson spectrophotometer no. 71 from September 1987 to December 1988 at Potsdam. The performance of the instrument types and the compatibility of ozone data was checked under the conditions of a field measuring station. Total ozone values derived from Dobson AD direct sun measurements were considered as standard. The Dobson instrument had been calibrated at intercomparisons with the World Standard Dobson instrument no. 83 (Boulder) and with the Regional Standard instrument no. 64 (Potsdam), while the Brewer instrument was calibrated several times with the Travelling Standard Brewer no. 17 (Canada). The differences between individual Brewer DS (direct sun) ozone data and Dobson ADDS are within plus or minus 3 percent with half of all differences within plus or minus 1 percent. Less than 0.7 percent of the systematic difference can be due to atmospheric SO2. Due to inadequate regression coefficients Brewer ZB (zenith blue) ozone measurements are by (3...4) percent higher than Dobson ADDS ozone values. M124 DS ozone data are systematically by (1...2) percent higher than Dobson ADDS ozone with 50 percent of the differences within plus or minus 4 percent, but with extreme differences up to plus or minus (20...25) percent. M124 ZB ozone values are by (3...5) percent higher than Dobson ADDS with all the differences within plus or minus 10 percent, i.e. the scatter of differences is smaller for ZB than for M 124 DS measurements, Results for differences in the daily mean ozone values are also addressed. The differences include the uncertainties in the ozone values derived from both types of measurements. They provide an indication of the uncertainty in ozone data and the comparability of ozone values derived from different types of instruments.

  5. Additive Manufacturing Infrared Inspection

    Science.gov (United States)

    Gaddy, Darrell; Nettles, Mindy

    2015-01-01

    The Additive Manufacturing Infrared Inspection Task started the development of a real-time dimensional inspection technique and digital quality record for the additive manufacturing process using infrared camera imaging and processing techniques. This project will benefit additive manufacturing by providing real-time inspection of internal geometry that is not currently possible and reduce the time and cost of additive manufactured parts with automated real-time dimensional inspections which deletes post-production inspections.

  6. Manufacturing in Denmark

    DEFF Research Database (Denmark)

    Hansen, Johannes; Boer, Henrike Engele Elisabeth; Boer, Harry

    This report compares the manufacturing strategies, practices, performances and improvement activities of 39 companies that are representative for the Danish assembly industry with those of 804 companies from 19 other countries. The data supporting this report were collected in 2013 and concern......: • Manufacturing strategies pursued and implemented between 2010 and 2012. • Performance improvements achieved during that period. • Actual manufacturing practices and performances as well as competitive priorities in 2012. • Manufacturing strategies pursued for the years 2010-2012....

  7. Manufacturing tolerant topology optimization

    DEFF Research Database (Denmark)

    Sigmund, Ole

    2009-01-01

    (dilated) structures compared to the intended topology. Examples are MEMS devices manufactured using etching processes, nano-devices manufactured using e-beam lithography or laser micro-machining and macro structures manufactured using milling processes. In the suggested robust topology optimization...

  8. Advanced Manufacturing Technologies (AMT): Manufacturing Initiative Project

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA supports the Advanced Manufacturing National Program Office (AMNPO). Hosted by the National Institute of Standards and Technology (NIST) the AMNPO is...

  9. Manufacturing Planning Guide

    Science.gov (United States)

    Waid, Michael

    2011-01-01

    Manufacturing process, milestones and inputs are unknowns to first-time users of the manufacturing facilities. The Manufacturing Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their project engineering personnel in manufacturing planning and execution. Material covered includes a roadmap of the manufacturing process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, products, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  10. ACE - Manufacturer Identification Code (MID)

    Data.gov (United States)

    Department of Homeland Security — The ACE Manufacturer Identification Code (MID) application is used to track and control identifications codes for manufacturers. A manufacturer is identified on an...

  11. The impact of the ozone effective temperature on satellite validation using the Dobson spectrophotometer network

    Science.gov (United States)

    Elissavet Koukouli, Maria; Zara, Marina; Lerot, Christophe; Fragkos, Konstantinos; Balis, Dimitris; van Roozendael, Michel; Antonius Franciscus Allart, Marcus; van der A, Ronald Johannes

    2016-05-01

    The main aim of the paper is to demonstrate an approach for post-processing of the Dobson spectrophotometers' total ozone columns (TOCs) in order to compensate for their known stratospheric effective temperature (Teff) dependency and its resulting effect on the usage of the Dobson TOCs for satellite TOCs' validation. The Dobson observations employed are those routinely submitted to the World Ozone and Ultraviolet Data Centre (WOUDC) of the World Meteorological Organization, whereas the effective temperatures have been extracted from two sources: the European Space Agency, ESA, Ozone Climate Change Initiative, Ozone-CCI, GODFIT version 3 (GOME-type Direct FITting) algorithm applied to the GOME2/MetopA, GOME2A, observations as well as the one derived from the European Centre for Medium-Range Weather Forecasts (ECMWF) outputs. Both temperature sources are evaluated utilizing co-located ozonesonde measurements also retrieved from the WOUDC database. Both GODFIT_v3 and ECMWF Teffs are found to be unbiased against the ozonesonde observations and to agree with high correlation coefficients, especially for latitudes characterized by high seasonal variability in Teff. The validation analysis shows that, when applying the GODFIT_v3 effective temperatures in order to post-process the Dobson TOC, the mean difference between Dobson and GOME2A GODFIT_v3 TOCs moves from 0.63 ± 0.66 to 0.26 ± 0.46 % in the Northern Hemisphere and from 1.25 ± 1.20 to 0.80 ± 0.71 % in the Southern Hemisphere. The existing solar zenith angle dependency of the differences has been smoothed out, with near-zero dependency up to the 60-65° bin and the highest deviation decreasing from 2.38 ± 6.6 to 1.37 ± 6.4 % for the 80-85° bin. We conclude that the global-scale validation of satellite TOCs against collocated Dobson measurements benefits from a post-correction using suitably estimated Teffs.

  12. [BPNN simulation of photocatalytic degradation of reactive scarlet BES by UV-Vis spectrophotometer].

    Science.gov (United States)

    Zhang, Yun-Tao; He, Guo-Li; Xiang, Ming-Li

    2009-10-01

    The use of chemometric techniques and multivariate experimental designs for the photocatalytic reaction of reactive scarlet BES in aqueous solution under ultraviolet light irradiation is described. The efficiency of photocatalytic degradation was evaluated by the analysis of the parameter of decoloration efficiency determined by UV absorption at 540 nm using a UV-Vis spectrophotometer in different conditions. Five factors, such as the amount of titanium oxide ([TiO2]), the concentrations of reactive scarlet BES (c(0)), irradiation time (t), the pH value (pH) and temperature (T), were studied. [TiO2]. c(0), t and pH selected on the basis of the results of variance analysis by Plackett-Burman design were used as independent variables. Training sets and test sets of back propagation neural network (BPNN) were formed by Box-Behnken design and uniform design U10 (10 x 5(2) x 2) respectively. The process of photocatalytic degradation of the target object was simulated by the BPNN model. The correlation coefficient (r) of the calculation results for training set and test set by BPNN is 0.996 4 and 0.963 6 respectively, and the mean relative errors between the predictive value and experimental value of decoloration efficiency are 6.14 and 7.76, respectively. The modeled BPNN was applied to analyze the influence of four factors on decoloration efficiency. The results showed that the initial conditions of c(0) being lower, pH 5.0 and appropriate amount of [TiO2] contribute to improving the decoloration efficiency of reactive scarlet BES. Under the condition of c(0) = 40 mg x L(-1), the optimized experimental condition of the system was obtained: [TiO2] = 1.20 g x L(-1) and pH 5.0. Under the optimized experimental condition, the experimental value of decoloration efficiency is 98.20% when irradiation time is 35 minutes and the predictive value of decoloration efficiency is 99.16% under the same condition. The relative error of decoloration efficiency between the predictive

  13. Manufacturing ontology through templates

    Directory of Open Access Journals (Sweden)

    Diciuc Vlad

    2017-01-01

    Full Text Available The manufacturing industry contains a high volume of knowhow and of high value, much of it being held by key persons in the company. The passing of this know-how is the basis of manufacturing ontology. Among other methods like advanced filtering and algorithm based decision making, one way of handling the manufacturing ontology is via templates. The current paper tackles this approach and highlights the advantages concluding with some recommendations.

  14. Manufacturing tolerant topology optimization

    OpenAIRE

    Sigmund, Ole

    2009-01-01

    In this paper we present an extension of the topology optimization method to include uncertainties during the fabrication of macro, micro and nano structures. More specifically, we consider devices that are manufactured using processes which may result in (uniformly) too thin (eroded) or too thick (dilated) structures compared to the intended topology. Examples are MEMS devices manufactured using etching processes, nano-devices manufactured using e-beam lithography or laser micro-machining an...

  15. Measuring Manufacturing Innovativeness

    DEFF Research Database (Denmark)

    Blichfeldt, Henrik; Knudsen, Mette Præst

    2017-01-01

    Globalization and customization increases the pressure on manufacturing companies, and the ability to provide innovativeness is a potential source of competitive advantage. This paper positions the manufacturing entity in the innovation process, and investigates the relation between innovation vers...... technology and organizational concepts. Based on Danish survey data from the European Manufacturing Survey (EMS-2015) this paper finds that there is a relation between innovative companies, and their level of technology and use of organizational concepts. Technology and organizational concepts act...

  16. Interexaminer reliability in clinical measurement of L*C*h* values of anterior teeth using a spectrophotometer.

    Science.gov (United States)

    Hassel, Alexander J; Grossmann, Anne-christiane; Schmitter, Marc; Balke, Zibandeh; Buzello, Anja M

    2007-01-01

    The objective of this study was to investigate interexaminer reliability in the clinical measurement of the L*C*h* (lightness/value, chroma, hue) values of anterior teeth using a spectrophotometer (Vita Easyshade). The basic color of the maxillary right central incisors and canines of 23 subjects was spectrophotometrically determined by 4 clinicians and an experienced user (development manager) of the spectrophotometer. Also, to analyze the effect of different training with the instrument on interexaminer reliability, 2 of the clinicians were instructed in the use of the spectrophotometer by the experienced examiner, whereas the others instructed themselves by studying the operating manual. Agreement between all examiners was acceptable to excellent (intraclass coefficient > 0.4). The mean value of the measured differences for the central incisors of all subjects for L* values was 5 (for C* = 3.8, h* = 2.7 degrees) and for canines, the mean L* was 4.5 (C* = 3, h* = 1.6 degrees). Results from comparison of the 2 different training methods were inconsistent. Agreement with the experienced examiner ranged from not acceptable (C* values for incisors of self-instructed examiners) to excellent. The distribution of the measurements of 1 subject could lead to deviations in color, probably with clinical impact. For canines, the measurements were at least equally reproducible (in some cases significantly more reproducible) compared to central incisors. Because of the small number of examiners and the inconsistent results, it was not possible to reach a definite conclusion about the effect of different training methods on interexaminer reliability.

  17. Sensitivity of digital dental photo CIE L*a*b* analysis compared to spectrophotometer clinical assessments over 6 months.

    Science.gov (United States)

    Sluzker, Ariel; Knösel, Michael; Athanasiou, Athanasios E

    2011-10-01

    To assess the sensitivity of digital dental photo CIE L*a*b* analysis compared to clinical spectrophotometer assessments over 6 months. CIE L*a*b* values for the upper right central incisors of 14 predoctoral dental students subjected to certain color-relevant exclusion criteria were recorded at baseline (T0), after 6 months (T1), and 1 week later (T2), using (Method 1) a spectrophotometer and (Method 2) a method of digital photo analysis. Statistical analysis of color and lightness data between both methods and time points were assessed using the Shapiro-Wilk test, Pearson's correlation coefficient (r), Dahlberg's formula for method error calculation, and paired samples t-tests, adopting a level of significance alpha = 0.05. Between T0 - T1, the spectrophotometer recorded significant changes in lightness (75.51 > 77.75) and color values (a*: 3.25 > 2.38; b*: 18.47 > 17.31), whereas significant changes with Method 2 were only seen for b* (21.51 > 20.57). No significant changes for overall color and lightness changes deltaE to deltaE2 were found for either of the methods. The error of the method (T1-T2) and corresponding correlation coefficients r for values L*a*b* were found to be 1.44 / 0.43 / 0.62 (r: 0.69; P = 0.007/0.64; P = 0.14/0.9; P < 0.001) for Method 1 and 0.97/0.67/1.25 (r : 0.87; P < 0.001/0.63; P = 0.17/0.57, P = 0.04) for Method 2, respectively.

  18. Manufacturing Demonstration Facility (MDF)

    Data.gov (United States)

    Federal Laboratory Consortium — The U.S. Department of Energy Manufacturing Demonstration Facility (MDF) at Oak Ridge National Laboratory (ORNL) provides a collaborative, shared infrastructure to...

  19. Advanced Manufacturing Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Advanced Manufacturing Laboratory at the University of Maryland provides the state of the art facilities for realizing next generation products and educating the...

  20. Composite Structures Manufacturing Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Composite Structures Manufacturing Facility specializes in the design, analysis, fabrication and testing of advanced composite structures and materials for both...

  1. Solubility and Dissolution Rate Determination of Different Antiretroviral Drugs in Different pH Media Using UV Visible Spectrophotometer

    OpenAIRE

    Prakash, K.; Narayana Raju, P.; Shanta Kumari, K.; Lakshmi Narasu, M.

    2008-01-01

    Solubility and dissolution rate of three antiretroviral drugs such as lamivudine, zidovudine and stavudine was studied in four media having different pH. The samples were analyzed by using UV Visible spectrophotometer. lamivudine shows more solubility that is 276.08 mg/mL in 0.01 N HCl. Stavudine showing highest solubility that is 101.23 mg/mL in pH 4.5 acetate buffer. Zidovudine showing highest solubility that is 28.90 mg/mL in both water and 0.01 N HCl. All three drugs showing lower solubi...

  2. Comparison of UV-B measurements performed with a Brewer spectrophotometer and a new UVB-1 broad band detector

    Science.gov (United States)

    Bais, Alkiviadis F.; Zerefos, Christos S.; Meleti, Charicleia; Ziomas, Ioannis C.

    1994-01-01

    Measurements of the UV-B erythemal dose, based on solar spectra acquired with a Brewer spectrophotometer at Thessaloniki, Greece, are compared to measurements performed with the recently introduced, by the Yankee Environmental Systems, (Robertson type) broad band solar UV-B detector. The spectral response function of this detector, when applied to the Brewer spectral UV-B measurements, results in remarkably comparable estimates of the erythemal UV-B dose. The two instruments provide similar information on the UV-B dose when they are cross-examined under a variety of meteorological and atmospheric conditions and over the a large range of solar zenith angles and total ozone.

  3. Assessing the engagement, learning, and overall experience of students operating an atomic absorption spectrophotometer with remote access technology.

    Science.gov (United States)

    Erasmus, Daniel J; Brewer, Sharon E; Cinel, Bruno

    2015-01-01

    The use of internet-based technologies in the teaching of laboratories has emerged as a promising education tool. This study evaluated the effectiveness of using remote access technology to operate an atomic absorption spectrophotometer in analyzing the iron content in a crude myoglobin extract. Sixty-two students were surveyed on their level of engagement, learning, and overall experience. Feedback from students suggests that the use of remote access technology is effective in teaching students the principles of chemical analysis by atomic absorption spectroscopy. © 2014 The International Union of Biochemistry and Molecular Biology.

  4. Cross-validity of a portable glucose capillary monitors in relation to enzymatic spectrophotometer methods

    Directory of Open Access Journals (Sweden)

    William Alves Lima

    2006-09-01

    Full Text Available The glucose is an important substrate utilizaded during exercise. Accurate measurement of glucose is vital to obtain trustworthy results. The enzymatic spectrophotometer methods are generally considered the “goldstandard” laboratory procedure for measuring of glucose (GEnz, is time consuming, costly, and inappropriate for large scale field testing. Compact and portable glucose monitors (GAccu are quick and easy methods to assess glucose on large numbers of subjects. So, this study aimed to test the cross-validity of GAccu. The sample was composed of 107 men (aged= 35.4±10.7 years; stature= 168.4±6.9 cm; body mass= 73.4±11.2 kg; %fat= 20.9±8.3% – by dual energy x-ray absorptiometry. Blood for measuring fasting glucose was taken in basilar vein (Genz, Bioplus: Bio-2000 and in ring finger (GAccu: Accu-Chek© Advantage©, after a 12-hour overnight fast. GEnz was used as the criterion for cross-validity. Paired t-test shown differences (p RESUMO A glicose é um substrato importante utilizado durante o exercício físico. Medidas acuradas da glicose são fundamentais para a obtenção de resultados confiáveis. O método laboratorial de espectrofotometria enzimática geralmente é considerado o procedimento “padrão ouro” para medir a glicose (GEnz, o qual requer tempo, custo e é inapropriado para o uso em larga escala. Monitores portáteis de glicose (GAccu são rápidos e fáceis para medir a glicose em um grande número de sujeitos. Então, este estudo teve por objetivo testar a validade concorrente do GAccu. A amostra foi composta por 107 homens (idade= 35,4±10,7 anos; estatura= 168,4±6,9 cm; massa corporal= 73,4±11,2 kg; %gordura= 20,9±8,3% – por absortometria de raio-x de dupla energia. O sangue para mensurar a glicose em jejum foi tirado na veia basilar (Genz, Bioplus: Bio-2000 e no dedo anular (GAccu - Accu- Chek© Advantage©, depois de 12h de jejum noturno. O GEnz foi usado como critério para testar a validade

  5. Improving Project Manufacturing Coordination

    Directory of Open Access Journals (Sweden)

    Korpivaara Ville

    2014-09-01

    Full Text Available The objective of this research is to develop firms’ project manufacturing coordination. The development will be made by centralizing the manufacturing information flows in one system. To be able to centralize information, a deep user need assessment is required. After user needs have been identified, the existing system will be developed to match these needs. The theoretical background is achieved through exploring the literature of project manufacturing, development project success factors and different frameworks and tools for development project execution. The focus of this research is rather in customer need assessment than in system’s technical expertise. To ensure the deep understanding of customer needs this study is executed by action research method. As a result of this research the information system for project manufacturing coordination was developed to respond revealed needs of the stakeholders. The new system improves the quality of the manufacturing information, eliminates waste in manufacturing coordination processes and offers a better visibility to the project manufacturing. Hence it provides a solid base for the further development of project manufacturing.

  6. Modern manufacturing engineering

    CERN Document Server

    2015-01-01

    This book covers recent research and trends in Manufacturing Engineering. The chapters emphasize different aspects of the transformation from materials to products. It provides the reader with fundamental materials treatments and the integration of processes. Concepts such as green and lean manufacturing are also covered in this book.

  7. New strategic roles of manufacturing

    DEFF Research Database (Denmark)

    Yang, Cheng; Johansen, John; Boer, Harry

    2008-01-01

    of manufacturing playing new strategic roles. Backward, forward and lateral interactive support are suggested to explicate how manufacturing can realize its new strategic roles. Finally, four new strategic roles of manufacturing are suggested. They are: innovation manufacturing, ramp-up manufacturing, primary...

  8. Micro/Nano manufacturing

    DEFF Research Database (Denmark)

    Tosello, Guido

    2017-01-01

    Micro- and nano-scale manufacturing has been the subject of an increasing amount of interest and research effort worldwide in both academia and industry over the past 10 years.Traditional (MEMS) manufacturing, but also precision manufacturing technologies have been developed to cover micro......-scale dimensions and accuracies. Furthermore, these fundamentally different technology ecosystems are currently combined in order to exploit strengths of both platforms. One example is the use of lithography-based technologies to establish nanostructures that are subsequently transferred to 3D geometries via...

  9. Competitive Manufacturing Dynamics

    DEFF Research Database (Denmark)

    Rymaszewska, Anna; Christensen, Irene; Karlsson, Christer

    to constantly improve this process in terms of time to volume, according to predefined cost and quality measures. The importance of the success of this process can lead to a significant creation of competitive advantage. This paper addresses the challenges of the manufacturing ramp-up process in the context......The increasing complexity of business environments and the pressure for organizations on delivering new products faster while maintaining the superior quality of their products, has forced manufacturing organizations to rethink their operations. Managers responsible for manufacturing ramp-up need...

  10. Absorber manufacturing made easy

    Energy Technology Data Exchange (ETDEWEB)

    Berner, Joachim

    2010-07-01

    Whether by means of a laser source or an ultrasound head - automation technology is making progress in the solar thermal sector. S and WE presents news developments in welding technology in absorber manufacture. (orig.)

  11. Many Manufactured Nanosats Project

    Data.gov (United States)

    National Aeronautics and Space Administration — To achieve the capability to affordably produce scores of nano-spacecraft for envisioned constellation missions, a new manufacturing process is needed to reduce the...

  12. The Manufacturing Industry

    National Research Council Canada - National Science Library

    Calahan, Janet; Grohoski, David C; Halevi, Herzi; Kett, Steven L; Klotsko, Jr., John A; Lett, Steven; Noyes, Julieta V; Oslund, Dawson S; Rackers, Kenneth J; Shindelar, Timothy V

    2005-01-01

    The United States (US) is the world's largest producer of manufactured goods, enabling the military and other government agencies to meet national security requirements while employing millions of Americans...

  13. Manufacturing parabolic mirrors

    CERN Multimedia

    CERN PhotoLab

    1975-01-01

    The photo shows the construction of a vertical centrifuge mounted on an air cushion, with a precision of 1/10000 during rotation, used for the manufacture of very high=precision parabolic mirrors. (See Annual Report 1974.)

  14. MEDICAL MANUFACTURING INNOVATIONS

    Directory of Open Access Journals (Sweden)

    Cosma Sorin Cosmin

    2015-02-01

    Full Text Available The purpose of these studies was to improve the design and manufacturing process by selective laser melting, of new medical implants. After manufacturing process, the implants were measured, microscopically and mechanical analyzed. Implants manufactured by AM can be an attractive option for surface coatings to improve the osseointegration process. The main advantages of customized implants made by AM process are: the precise adaptation to the region of implantation, better cosmesis, reduced surgical times and better performance over their generic counterparts. These medical manufacturing changes the way that the surgeons are planning surgeries and engineers are designing custom implant. AM process has eliminated the constraints of shape, size, internal structure and mechanical properties making it possible for fabrication of implants that conform to the physical and mechanical requirements of implantation according to CT images. This article will review some custom implants fabricated in DME using biocompatible titanium.

  15. Quantification of dsDNA using the Hitachi F-7000 Fluorescence Spectrophotometer and PicoGreen dye.

    Science.gov (United States)

    Moreno, Luis A; Cox, Kendra L

    2010-11-05

    Quantification of DNA, especially in small concentrations, is an important task with a wide range of biological applications including standard molecular biology assays such as synthesis and purification of DNA, diagnostic applications such as quantification of DNA amplification products, and detection of DNA molecules in drug preparations. During this video we will demonstrate the capability of the Hitachi F-7000 Fluorescence Spectrophotometer equipped with a Micro Plate Reader accessory to perform dsDNA quantification using Molecular Probes Quant-it PicoGreen dye reagent kit. The F-7000 Fluorescence Spectrophotometer offers high sensitivity and high speed measurements. It is a highly flexible system capable of measuring fluorescence, luminescence, and phosphorescence. Several measuring modes are available, including wavelength scan, time scan, photometry and 3-D scan measurement. The spectrophotometer has sensitivity in the range of 50 picomoles of fluorescein when using a 300 μL sample volume in the microplate, and is capable of measuring scan speeds of 60,000 nm/minute. It also has a wide dynamic range of up to 5 orders of magnitude which allows for the use of calibration curves over a wide range of concentrations. The optical system uses all reflective optics for maximum energy and sensitivity. The standard wavelength range is 200 to 750 nm, and can be extended to 900 nm when using one of the optional near infrared photomultipliers. The system allows optional temperature control for the plate reader from 5 to 60 degrees Celsius using an optional external temperature controlled liquid circulator. The microplate reader allows for the use of 96 well microplates, and the measuring speed for 96 wells is less than 60 seconds when using the kinetics mode. Software controls for the F-7000 and Microplate Reader are also highly flexible. Samples may be set in either column or row formats, and any combination of wells may be chosen for sample measurements. This allows

  16. Holonic Manufacturing Paint Shop

    Science.gov (United States)

    Lind, Morten; Roulet-Dubonnet, Olivier; Nyen, Per Åge; Gellein, Lars Tore; Lien, Terje; Skavhaug, Amund

    In pursuit of flexibility and agility within discrete manufacturing, the surrounding logistics and handling processes of a paint shop is under construction as a laboratory prototype application. Holonic Manufacturing seems to be a promising strategic paradigm and architecture to use for a system characterised by production logistics and control. This paper describes the physical devices to be used; the desired functionality; and the basic logic control designed. Additionally, the ideas for holonification based on the already designed logic control is presented.

  17. Additive manufactured serialization

    Science.gov (United States)

    Bobbitt, III, John T.

    2017-04-18

    Methods for forming an identifying mark in a structure are described. The method is used in conjunction with an additive manufacturing method and includes the alteration of a process parameter during the manufacturing process. The method can form in a unique identifying mark within or on the surface of a structure that is virtually impossible to be replicated. Methods can provide a high level of confidence that the identifying mark will remain unaltered on the formed structure.

  18. Assessment of toxic metals in raw and processed milk samples using electrothermal atomic absorption spectrophotometer.

    Science.gov (United States)

    Kazi, Tasneem Gul; Jalbani, Nusrat; Baig, Jameel Ahmed; Kandhro, Ghulam Abbas; Afridi, Hassan Imran; Arain, Mohammad Balal; Jamali, Mohammad Khan; Shah, Abdul Qadir

    2009-09-01

    Milk and dairy products have been recognized all over the world for their beneficial influence on human health. The levels of toxic metals (TMs) are an important component of safety and quality of milk. A simple and efficient microwave assisted extraction (MAE) method has been developed for the determination of TMs (Al, Cd, Ni and Pb), in raw and processed milk samples. A Plackett-Burman experimental design and 2(3)+star central composite design, were applied in order to determine the optimum conditions for MAE. Concentrations of TMs were measured by electrothermal atomic absorption spectrometry. The accuracy of the optimized procedure was evaluated by standard addition method and conventional wet acid digestion method (CDM), for comparative purpose. No significant differences were observed (P>0.05), when comparing the values obtained by the proposed MAE method and CDM (paired t-test). The average relative standard deviation of the MAE method varied between 4.3% and 7.6% based on analyte (n=6). The proposed method was successfully applied for the determination of understudy TMs in milk samples. The results of raw and processed milk indicated that environmental conditions and manufacturing processes play a key role in the distribution of toxic metals in raw and processed milk.

  19. Energetics Manufacturing Technology Center (EMTC)

    Data.gov (United States)

    Federal Laboratory Consortium — The Energetics Manufacturing Technology Center (EMTC), established in 1994 by the Office of Naval Research (ONR) Manufacturing Technology (ManTech) Program, is Navy...

  20. Use of Fourier transformed infrared spectrophotometer (FTIR) for determination of breastmilk output by the deuterium dilution method among Senegalese women

    International Nuclear Information System (INIS)

    Sarr Cisse, Aita; Diaham, Babou; Dossou, Nicole; Guiro, Amadou Tidiane; Wade, Salimata; Bluck, Leslie

    2002-01-01

    Breastmilk output can be estimated from the mother's total body water and water turnover rates after oral administration of deuterium oxide. Usually the deuterium enrichments are determined using a isotope ratio mass spectrometer, which is expensive and requires a specialist for operation and maintenance. Such equipment is dfficult to set up in developing countries. A less expensive method was developed which uses a Fourier transform infrared spectrophotometer (FTIR) for deuterium enrichment analysis. This study evaluated the constraints of using FTIR to study lactating women in Senegal. The deuterium isotope method was found to be adequate for free living subjects and presented few constraints except for the duration of the saliva sampling (14 days). The method offers the opportunity to determine simultaneously breastmilk output, mother's body composition, and breastfeeding practices. Deuterium sample enrichments measured with FTIR were fast and easy, but for spectrum quality some environmental control is required to optimize the results. (Authors)

  1. Signal-to-noise optimization and evaluation of a home-made visible diode-array spectrophotometer

    Science.gov (United States)

    Raimundo, Jr., Ivo M.; Pasquini, Celio

    1993-01-01

    This paper describes a simple low-cost multichannel visible spectrophotometer built with an RL512G EGG-Reticon photodiode array. A symmetric Czerny-Turner optical design was employed; instrument control was via a single-board microcomputer based on the 8085 Intel microprocessor. Spectral intensity data are stored in the single-board's RAM and then transferred to an IBM-AT 3865X compatible microcomputer through a RS-232C interface. This external microcomputer processes the data to recover transmittance, absorbance or relative intensity of the spectra. The signal-to-noise ratio and dynamic range were improved by using variable integration times, which increase during the same scan; and by the use of either weighted or unweighted sliding average of consecutive diodes. The instrument is suitable for automatic methods requiring quasi-simultaneous multiwavelength detections, such as multivariative calibration and flow-injection gradient scan techniques. PMID:18924979

  2. Total ozone derived from UV spectrophotometer measurements on the NASA CV-990 aircraft for the fall 1976 latitude survey flights

    Science.gov (United States)

    Hanser, F. A.

    1977-01-01

    An ultraviolet interference filter spectrophotometer was modified to use a photodiode and was flown on latitude survey flights in the fall of 1976. Comparison with Dobson station total ozone values shows agreement between UVS and Dobson total ozone of + or - 2 percent. The procedure used to convert UVS measured ozone above the aircraft altitude to total ozone above ground level introduces an additional 2 percent deviation for very high altitude UVS ozone data. Under stable aircraft operating conditions, the UVS derived ozone values have a variability, or reproducibility, of better than + or -1 percent. The UVS data from the latitude survey flights yield a detailed latitude profile of total ozone over the Pacific Ocean during November 1976. Significant latitudinal structure in total ozone is found at the middle latitudes (30 deg to 40 deg N and S).

  3. Normal incidence spectrophotometer using high density transmission grating technology and highly efficiency silicon photodiodes for absolute solar EUV irradiance measurements

    Science.gov (United States)

    Ogawa, H. S.; Mcmullin, D.; Judge, D. L.; Korde, R.

    1992-01-01

    New developments in transmission grating and photodiode technology now make it possible to realize spectrometers in the extreme ultraviolet (EUV) spectral region (wavelengths less than 1000 A) which are expected to be virtually constant in their diffraction and detector properties. Time dependent effects associated with reflection gratings are eliminated through the use of free standing transmission gratings. These gratings together with recently developed and highly stable EUV photodiodes have been utilized to construct a highly stable normal incidence spectrophotometer to monitor the variability and absolute intensity of the solar 304 A line. Owing to its low weight and compactness, such a spectrometer will be a valuable tool for providing absolute solar irradiance throughout the EUV. This novel instrument will also be useful for cross-calibrating other EUV flight instruments and will be flown on a series of Hitchhiker Shuttle Flights and on SOHO. A preliminary version of this instrument has been fabricated and characterized, and the results are described.

  4. Method for improving the use of PASCO brand spectrophotometer using DataStudio program applied to radiometric surveys for LAFTLA

    International Nuclear Information System (INIS)

    Bolanos Rodriguez, Gary

    2008-01-01

    Escuela de Ingenieria Electrica at the Universidad de Costa Rica has developed a procedure for the improved use of a PASCO brand Spectrophotometer of the Laboratorio de Fotonica y Tecnologia Laser Aplicada. The program has used DataStudio for the application in radiometric surveys in LAFTLA. Important conclusions have been obtained by the assembly of optical experiments, software and data collection and analysis, such as the behavior of a emitting source radiation known as black body and its relation to the temperature, wavelength and intensity of light. The user guide has been detailed exposing calibrations of the sensors, the definition of constants needed for obtaining parameters and assembly and commissioning of the equipment. (author) [es

  5. infrared spectrophotometer for simultaneous detection of traces of heavy water and indocyanine green in flowing blood. In vivo experimentation

    International Nuclear Information System (INIS)

    Capitini, R.; Roveyaz, P.

    1981-07-01

    We have developed an infrared absorption method for the pulmonary extravascular water and cardiac output determination by the multiple indicator technique. This led us to construct an original double differential spectrophotometer (DUPLEX) for simultaneous detection of traces of heavy water (D 2 O) and indocyanine green (ICG) in circulating blood in a single absorption cell. This DUPLEX is connected to a computer and results are treated on line. D 2 O and ICG are used as non toxic diffusible and vascular tracers respectively. Performances of the DUPLEX are given and show a high accuracy with D 2 O (x 10) and ICG (x 2) compared with the commercial optical analysers. We show the validity of the method for determining the cardiac output and the pulmonary extravascular water in the course of numerous experiments on human and rats subjects. Preliminary results concerning the measurement of global water on rats are also given [fr

  6. Concentration Determination of Nucleic Acids and Proteins Using the Micro-volume Bio-spec Nano Spectrophotometer

    Science.gov (United States)

    Sukumaran, Suja

    2011-01-01

    Nucleic Acid quantitation procedures have advanced significantly in the last three decades. More and more, molecular biologists require consistent small-volume analysis of nucleic acid samples for their experiments. The BioSpec-nano provides a potential solution to the problems of inaccurate, non-reproducible results, inherent in current DNA quantitation methods, via specialized optics and a sensitive PDA detector. The BioSpec-nano also has automated functionality such that mounting, measurement, and cleaning are done by the instrument, thereby eliminating tedious, repetitive, and inconsistent placement of the fiber optic element and manual cleaning. In this study, data is presented on the quantification of DNA and protein, as well as on measurement reproducibility and accuracy. Automated sample contact and rapid scanning allows measurement in three seconds, resulting in excellent throughput. Data analysis is carried out using the built-in features of the software. The formula used for calculating DNA concentration is: Sample Concentration = DF · (OD260-OD320)· NACF (1) Where DF = sample dilution factor and NACF = nucleic acid concentration factor. The Nucleic Acid concentration factor is set in accordance with the analyte selected1. Protein concentration results can be expressed as μg/ mL or as moles/L by entering e280 and molecular weight values respectively. When residue values for Tyr, Trp and Cysteine (S-S bond) are entered in the e280Calc tab, the extinction coefficient values are calculated as e280 = 5500 x (Trp residues) + 1490 x (Tyr residues) + 125 x (cysteine S-S bond). The e280 value is used by the software for concentration calculation. In addition to concentration determination of nucleic acids and protein, the BioSpec-nano can be used as an ultra micro-volume spectrophotometer for many other analytes or as a standard spectrophotometer using 5 mm pathlength cells. PMID:21372788

  7. Spectrophotometer is useful for assessing vitiligo and chemical leukoderma severity by quantifying color difference with surrounding normally pigmented skin.

    Science.gov (United States)

    Hayashi, M; Okamura, K; Araki, Y; Suzuki, M; Tanaka, T; Abe, Y; Nakano, S; Yoshizawa, J; Hozumi, Y; Inoie, M; Suzuki, T

    2017-10-22

    Acquired skin hypopigmentation has many etiologies, including autoimmune melanocyte destruction, skin aging, inflammation, and chemical exposure. Distinguishing lesions from normally pigmented skin is clinically important to precisely assess disease severity. However, no gold standard assessment method has been reported. We aimed to investigate whether spectrophotometers are useful for assessing vitiligo and rhododendrol (4-(4-hydroxyphenol)-2-butanol) (Rhododenol ® )-induced leukoderma disease severity by quantifying skin color. Mexameter ® MX18 and CM-700d spectrophotometer were used for assessing vitiligo/leukoderma by measuring melanin index, L*a*b* color space, and ΔE*ab value, which represents the color difference between two subjects and is calculated by the values of L*a*b*. MX18 and CM-700d can quantitatively distinguish vitiligo/leukoderma from normally pigmented skin based on melanin index. CM-700d consistently quantified the color of vitiligo/leukoderma lesions and surrounding normally pigmented skin in L*a*b* color spaces and ΔE*ab. ΔE*ab is well correlated with melanin index and clinical appearance. ΔE*ab has been frequently used in aesthetic dentistry; however, current study is the first to use it in the measurement of skin color. ΔE*ab seems to be a useful parameter to evaluate the color contrast between vitiligo/leukoderma and surrounding normally pigmented skin and can be used to evaluate disease severity and patient's quality of life. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Concentration determination of nucleic acids and proteins using the micro-volume BioSpec-nano-spectrophotometer.

    Science.gov (United States)

    Sukumaran, Suja

    2011-02-17

    Nucleic acid quantitation procedures have advanced significantly in the last three decades. More and more, molecular biologists require consistent small-volume analysis of nucleic acid samples for their experiments. The BioSpec-nano provides a potential solution to the problems of inaccurate, non-reproducible results, inherent in current DNA quantitation methods, via specialized optics and a sensitive PDA detector. The BioSpec-nano also has automated functionality such that mounting, measurement, and cleaning are done by the instrument, thereby eliminating tedious, repetitive, and inconsistent placement of the fiber optic element and manual cleaning. In this study, data is presented on the quantification of DNA and protein, as well as on measurement reproducibility and accuracy. Automated sample contact and rapid scanning allows measurement in three seconds, resulting in excellent throughput. Data analysis is carried out using the built-in features of the software. The formula used for calculating DNA concentration is: Sample Concentration = DF · (OD260-OD320)· NACF (1) Where DF = sample dilution factor and NACF = nucleic acid concentration factor. The Nucleic Acid concentration factor is set in accordance with the analyte selected. Protein concentration results can be expressed as μg/mL or as moles/L by entering e280 and molecular weight values respectively. When residue values for Tyr, Trp and Cysteine (S-S bond) are entered in the e280Calc tab, the extinction coefficient values are calculated as e280 = 5500 x (Trp residues) + 1490 x (Tyr residues) + 125 x (cysteine S-S bond). The e280 value is used by the software for concentration calculation. In addition to concentration determination of nucleic acids and protein, the BioSpec-nano can be used as an ultra micro-volume spectrophotometer for many other analytes or as a standard spectrophotometer using 5 mm pathlength cells.

  9. Analysis of Shade Matching in Natural Dentitions Using Intraoral Digital Spectrophotometer in LED and Filtered LED Light Sources.

    Science.gov (United States)

    Chitrarsu, Vijai Krishnan; Chidambaranathan, Ahila Singaravel; Balasubramaniam, Muthukumar

    2017-10-31

    To evaluate the shade matching capabilities in natural dentitions using Vita Toothguide 3D-Master and an intraoral digital spectrophotometer (Vita Easyshade Advance 4.0) in various light sources. Participants between 20 and 40 years old with natural, unrestored right maxillary central incisors, no history of bleaching, orthodontic treatment, or malocclusion and no rotations were included. According to their shades, subjects were randomly selected and grouped into A1, A2, and A3. A total of 100 participants (50 male and 50 female) in each group were chosen for this study. Shade selection was made between 10 am and 2 pm for all light sources. The same examiner selected the shade of natural teeth with Vita Toothguide 3D-Master under natural light within 2 minutes. Once the Vita Toothguide 3D-Masterwas matched with the maxillary right central incisor, the L*, a*, and b* values, chroma, and hue were recorded with Vita Easyshade Advance 4.0 by placing it on the shade tab under the same light source. The values were statistically analyzed using one-way ANOVA and Tukey's HSD post hoc test with SPSS v22.0 software. The mean ∆E* ab values for shades A1, A2, and A3 for groups 1, 2, and 3 were statistically significantly different from each other (p spectrophotometer showed statistically significant differences in shade matching compared to Vita Toothguide 3D-Master. Incandescent light showed more accurate shade matching than the filtered LED, LED, and daylight. © 2017 by the American College of Prosthodontists.

  10. An in vitro comparison of quantitative light-induced fluorescence-digital and spectrophotometer on monitoring artificial white spot lesions.

    Science.gov (United States)

    Kim, Hee Eun; Kim, Baek-Il

    2015-09-01

    The aim of this study was to evaluate the efficacy of quantitative light-induced fluorescence-digital (QLF-D) compared to a spectrophotometer in monitoring progression of enamel lesions. To generate artificial caries with various severities of lesion depths, twenty bovine specimens were immersed in demineralizing solution for 40 days. During the production of the lesions, repeat measurements of fluorescence loss (ΔF) and color change (ΔE) were performed in six distinct stages after the demineralization of the specimens: after 3, 5, 10, 20, 30, and 40 days of exposure to the demineralizing solution. Changes in the ΔF values in the lesions were analyzed using the QLF-D, and changes in the ΔE values in lesions were analyzed using a spectrophotometer. The repeated measures ANOVA of ΔF and ΔE values were used to determine whether there are significant differences at different exposure times in the demineralizing solution. Spearman's rank correlation coefficient was analyzed between ΔF and ΔE. The ΔF values significantly decreased based on the demineralizing period (p<0.001). Relatively large changes in ΔF values were observed during the first 10 days. There were significant changes in L(*), a(*), b(*), and ΔE values in lesions with increasing demineralizing duration (p<0.001). A strong correlation was observed between ΔF and ΔE with p=-0.853 (p<0.001). The results support the efficacy of QLF-D in monitoring color changes. Our findings demonstrate that QLF-D are a more efficient and stable tool for early caries detection. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Robust Manufacturing Control

    CERN Document Server

    2013-01-01

    This contributed volume collects research papers, presented at the CIRP Sponsored Conference Robust Manufacturing Control: Innovative and Interdisciplinary Approaches for Global Networks (RoMaC 2012, Jacobs University, Bremen, Germany, June 18th-20th 2012). These research papers present the latest developments and new ideas focusing on robust manufacturing control for global networks. Today, Global Production Networks (i.e. the nexus of interconnected material and information flows through which products and services are manufactured, assembled and distributed) are confronted with and expected to adapt to: sudden and unpredictable large-scale changes of important parameters which are occurring more and more frequently, event propagation in networks with high degree of interconnectivity which leads to unforeseen fluctuations, and non-equilibrium states which increasingly characterize daily business. These multi-scale changes deeply influence logistic target achievement and call for robust planning and control ...

  12. X-ray spectrophotometer SphinX and particle spectrometer STEP-F of the satellite experiment CORONAS-PHOTON. Preliminary results of the joint data analysis

    Science.gov (United States)

    Dudnik, O. V.; Podgorski, P.; Sylwester, J.; Gburek, S.; Kowalinski, M.; Siarkowski, M.; Plocieniak, S.; Bakala, J.

    2012-04-01

    A joint analysis is carried out of data obtained with the help of the solar X-ray SphinX spectrophotometer and the electron and proton satellite telescope STEP-F in May 2009 in the course of the scientific space experiment CORONAS-PHOTON. In order to determine the energies and particle types, in the analysis of spectrophotometer records data are used on the intensities of electrons, protons, and secondary γ-radiation, obtained by the STEP-F telescope, which was located in close proximity to the SphinX spectrophotometer. The identical reaction of both instruments is noted at the intersection of regions of the Brazilian magnetic anomaly and the Earth's radiation belts. It is shown that large area photodiodes, serving as sensors of the X-ray spectrometer, reliably record electron fluxes of low and intermediate energies, as well as fluxes of the secondary gamma radiation from construction materials of detector modules, the TESIS instrument complex, and the spacecraft itself. The dynamics of electron fluxes, recorded by the SphinX spectrophotometer in the vicinity of a weak geomagnetic storm, supplements the information about the processes of radial diffusion of electrons, which was studied using the STEP-F telescope.

  13. Laser in manufacturing

    CERN Document Server

    Davim, J Paulo

    2013-01-01

    Generally a laser (light amplification by stimulated emission of radiation) is defined as "a device which uses a quantum mechanical effect, stimulated emission, to generate a coherent beam of light from a lasing medium of controlled purity, size, and shape". Laser material processing represents a great number of methods, which are rapidly growing in current and different industrial applications as new alternatives to traditional manufacturing processes. Nowadays, the use of lasers in manufacturing is an emerging area with a wide variety of applications, for example, in electronics, molds an

  14. Manufacturing and Merchandising Careers

    Science.gov (United States)

    Ryan, Peter J.; And Others

    1977-01-01

    Anyone with a flair for business, product development, or promotion might consider a manufacturing or merchandising occupation. The music industry offers many career opportunities for administrators, salespersons, marketing specialists--the record industry offers positions from promotion manager to rack jobber. Describes instrument company…

  15. Advances in Additive Manufacturing

    Science.gov (United States)

    2016-07-14

    State University, Applied Research Laboratory • Rich Martukanitz • Ken Meinert • Ted Reutzel • Jay Keist • Griffin Jones • Jay Tressler...Directorate. In this talk we highlight a few projects in additively manufactured electronics (e.g., batteries, capacitors, antennas) that span bench

  16. Drug development and manufacturing

    Science.gov (United States)

    Warner, Benjamin P.; McCleskey, T. Mark; Burrell, Anthony K.

    2015-10-13

    X-ray fluorescence (XRF) spectrometry has been used for detecting binding events and measuring binding selectivities between chemicals and receptors. XRF may also be used for estimating the therapeutic index of a chemical, for estimating the binding selectivity of a chemical versus chemical analogs, for measuring post-translational modifications of proteins, and for drug manufacturing.

  17. Nuclear fuel manufacture

    International Nuclear Information System (INIS)

    Costello, J.M.

    1980-09-01

    The technologies used to manufacture nuclear fuel from uranium ore are outlined, with particular reference to the light water reactor fuel cycle. Capital and operating cost estimates for the processing stages are given, and the relevance to a developing uranium industry in Australia is discussed

  18. Rapid response manufacturing (RRM)

    Energy Technology Data Exchange (ETDEWEB)

    Cain, W.D. [Lockheed Martin Energy Systems, Inc., Oak Ridge, TN (United States); Waddell, W.L. [National Centers for Manufacturing Sciences, Ann Arbor, MI (United States)

    1997-02-18

    US industry is fighting to maintain its competitive edge in the global market place. Today markets fluctuate rapidly. Companies, to survive, have to be able to respond with quick-to-market, improved, high quality, cost efficient products. The way products are developed and brought to market can be improved and made more efficient through the proper incorporation of emerging technologies. The RRM project was established to leverage the expertise and resources of US private industries and federal agencies to develop, integrate, and deploy new technologies that meet critical needs for effective product realization. The RRM program addressed a needed change in the US Manufacturing infrastructure that will ensure US competitiveness in world market typified by mass customization. This project provided the effort needed to define, develop and establish a customizable infrastructure for rapid response product development design and manufacturing. A major project achievement was the development of a broad-based framework for automating and integrating the product and process design and manufacturing activities involved with machined parts. This was accomplished by coordinating and extending the application of feature-based product modeling, knowledge-based systems, integrated data management, and direct manufacturing technologies in a cooperative integrated computing environment. Key technological advancements include a product model that integrates product and process data in a consistent, minimally redundant manner, an advanced computer-aided engineering environment, knowledge-based software aids for design and process planning, and new production technologies to make products directly from design application software.

  19. Manufacturing Enterprise in Asia

    International Development Research Centre (IDRC) Digital Library (Canada)

    2017-12-13

    Dec 13, 2017 ... The book goes on to investigate the problem of the peculiar dual size structure of manufacturing in India, with its two modes at the low and high end of the ...... Foreign investment was welcomed in the period since the early 1960s, first, as Taiwan sought replacement for US foreign aid, and second, after the ...

  20. Precursor Additive Manufacturing Inventions

    Science.gov (United States)

    Roberts, C.; Bourell, D.

    2018-03-01

    Most modern Additive Manufacturing (AM) processes were invented and commercialized in a short period of time spanning 1984-2000. This paper reports on AM processes invented in the 1974-1987 time period, known as precursor AM processes. The critical difference between the two periods is public knowledge and utilization of distributed computing.

  1. Reusing Old Manufacturing Buildings

    Science.gov (United States)

    Roman, Harry T.

    2014-01-01

    This article presents an interesting design challenge for students, one that will certainly let them integrate subject matter and get a sense of pride for doing something useful in their own community. The author would be willing to bet that the average town or city has some old red brick manufacturing building(s) that have seen much better days.…

  2. Fundamentals of Digital Manufacturing Science

    CERN Document Server

    Zhou, Zude; Chen, Dejun

    2012-01-01

    The manufacturing industry will reap significant benefits from encouraging the development of digital manufacturing science and technology. Digital Manufacturing Science uses theorems, illustrations and tables to introduce the definition, theory architecture, main content, and key technologies of digital manufacturing science. Readers will be able to develop an in-depth understanding of the emergence and the development, the theoretical background, and the techniques and methods of digital manufacturing science. Furthermore, they will also be able to use the basic theories and key technologies described in Digital Manufacturing Science to solve practical engineering problems in modern manufacturing processes. Digital Manufacturing Science is aimed at advanced undergraduate and postgraduate students, academic researchers and researchers in the manufacturing industry. It allows readers to integrate the theories and technologies described with their own research works, and to propose new ideas and new methods to...

  3. Total ozone trends at sixteen NOAA/CMDL and Cooperative Dobson Spectrophotometer Observatories during 1979-1996

    Science.gov (United States)

    Komhyr, W. D.; Reinsel, G. C.; Evans, R. D.; Quincy, D. M.; Grass, R. D.; Leonard, R. K.

    Ozone trends, derived from 1979-1996 Dobson spectrophotometer total ozone data obtained at five U.S. mainland midlatitude stations, averaged -3.4, -4.9, -2.6, -1.9, and -3.3%/decade for winter, spring, summer, and autumn months, and on an annual basis, respectively. At the lower latitude stations of Mauna Loa and Samoa, corresponding-period annual ozone trends were -0.4 and -1.3%/decade, respectively, while at Huancayo, Peru, the 1979-1991 annual trend was -0.9%/decade. A linear trend approximation to ozone changes that occurred since 1978 during austral daylight times at Amundsen-Scott (South Pole) station, Antarctica, yielded a value of -12%/decade. By combining 1979-1996 annual trend data for three U.S. mainland stations with trends for the sites derived from 1963-1978 data, it is estimated that the ozone decrease at U.S. midlatitudes through 1996, relative to ozone present in the mid-1960s, was -6.7%. Similar analyses incorporating South Pole data obtained since 1963 yielded an ozone change at South Pole (daylight observations) through 1996 of approximately -25%. South Pole October total ozone values in 1996 were lower than mid-1960s October ozone values by a factor of two. Trend data are also presented for several shorter record period stations, including the foreign cooperative stations of Haute Provence, France; Lauder, New Zealand; and Perth, Australia.

  4. Intersstellar absorption lines between 2000 and 3000 A in nearby stars observed with BUSS. [Balloon Borne Ultraviolet Spectrophotometer

    Science.gov (United States)

    De Boer, K. S.; Lenhart, H.; Van Der Hucht, K. A.; Kamperman, T. M.; Kondo, Y.

    1986-01-01

    Spectra obtained between 2000 and 3000 A with the Balloon Borne Ultraviolet Spectrophotometer (BUSS) payload were examined for interstellar absorption lines. In bright stars, with spectral types between O9V and F5V, such lines were measured of Mg I, Mg II, Cr II, Mn II, Fe II and Zn II, with Cr II and Zn II data of especially high quality. Column densities were derived and interstellar abundances were determined for the above species. It was found that metal depletion increases with increasing E(B-V); Fe was most affected and Zn showed a small depletion for E(B-V) greater than 0.3 towards Sco-Oph. The metal column densities, derived for Alpha-And, Kappa-Dra, Alpha-Com, Alpha-Aql, and 29 Cyg were used to infer N(H I). It was shown that the ratio of Mg I to Na I is instrumental in determining the ionization structure along each line of sight. The spectra of Aql stars confirms the presence of large gas densities near Alpha-Oph. Moreover, data indicated that the Rho-Oph N(H I) value needs to be altered to 35 x 10 to the 20th/sq cm, based on observed ion ratios and analysis of the Copernicus L-alpha profile.

  5. Influence of Iatrogenic Gaps, Cement Type, and Time on Microleakage of Cast Posts Using Spectrophotometer and Glucose Filtration Measurements.

    Science.gov (United States)

    Al-Madi, Ebtissam M; Al-Saleh, Samar A; Al-Khudairy, Reem I; Aba-Hussein, Taibah W

    2018-04-06

    To determine the influence of iatrogenic gaps, type of cement, and time on microleakage of cast posts using spectrophotometer and glucose filtration measurements. Forty-eight single-rooted teeth were divided into eight groups of six teeth each. Teeth were instrumented and obturated, and a cast post was fabricated. In addition to two control groups (positive and negative), a total of six groups were prepared: In four groups, an artificial 2- to 3-mm gap was created between post and residual gutta percha (GP), and two groups were prepared with intimate contact between post and residual GP. Posts were cemented with either zinc phosphate cement or resin cement. Leakage through the post after 1, 8, 14, and 20 days was measured using a glucose penetration model with two different reading methods. Mixed analysis of variance tests were performed to analyze the data. The presence of a gap between the apical end of the post and the most coronal portion of the GP remaining in the root canal after post space preparation increased microleakage significantly. However, microleakage was significantly less when the gap was refilled with GP compared to no gap. There was no difference in leakage between luting cements used. It was concluded that none of the cements were able to prevent microleakage. However, the addition of GP to residual GP did increase the sealing ability.

  6. Influence of surface layer removal of shade guide tabs on the measured color by spectrophotometer and spectroradiometer.

    Science.gov (United States)

    Kim, Jin-Cheol; Yu, Bin; Lee, Yong-Keun

    2008-12-01

    To determine the changes in color parameters of Vitapan 3D-Master shade guide tabs by a spectrophotometer (SP) or a spectroradiometer (SR), and by the removal of the surface layer of the tabs that was performed to make a flat measuring surface for the SP color measurement. Color of the shade tabs was measured before and after removing the surface layer of the tabs using SP and SR. Correlations between the color parameters between the original (OR) and the surface layer removed (RM) tabs and between the SP and the SR measurements were determined (alpha=0.05). Based on SP, the lightness, chroma, CIE a* and b* values measured after the surface layer removal were higher than those of the original tabs except a few cases. Based on SR, the chroma and CIE a* and b* values measured after surface layer removal were higher than those of the original tabs except a few cases; however, in case of the lightness, the changes varied by the shade designation. Type of instrument influenced the changes in color parameters based on paired t-test (pspectrophotometer or a spectroradiometer, measurement protocols should be specified because color difference by the surface layer removal and the instrument was high.

  7. Manufacturing Optimization Based on Agile Manufacturing and Big Data

    OpenAIRE

    Khan, Md Ashikul Alam; Mebrahtu, Habtom; Shirvani, Hassan; Butt, Javaid

    2017-01-01

    This paper investigates Agile Manufacturing (AM) supported by Big Data for manufacturing optimization. The paper aims to identify the limitations of current manufacturing approaches such as just in time (JIT) and lean manufacturing and to map a process based on these limitations.The process works through a process re-engineering (PR) by eliminating and redesigning the steps that affect productions. The process will identify the key enablers that will assist in the design of an effective AM fr...

  8. Robot skills for manufacturing

    DEFF Research Database (Denmark)

    Pedersen, Mikkel Rath; Nalpantidis, Lazaros; Andersen, Rasmus Skovgaard

    2016-01-01

    Due to a general shift in manufacturing paradigm from mass production towards mass customization, reconfigurable automation technologies, such as robots, are required. However, current industrial robot solutions are notoriously difficult to program, leading to high changeover times when new......-asserting robot skills for manufacturing. We show how a relatively small set of skills are derived from current factory worker instructions, and how these can be transferred to industrial mobile manipulators. General robot skills can not only be implemented on these robots, but also be intuitively concatenated...... to program the robots to perform a variety of tasks, through the use of simple task-level programming methods. We demonstrate various approaches to this, extensively tested with several people inexperienced in robotics. We validate our findings through several deployments of the complete robot system...

  9. The manufacturers' viewpoint

    International Nuclear Information System (INIS)

    Davis, D.A.

    1986-01-01

    This paper describes the approach by six separate manufacturers to the problem of availability from their particular view point. This presentation demonstrates basic strategy: attention to high reliability at the design phase, based on positive and detailed feedback from existing plant; quality assurance at the production stage which has been planned into the production process in the form of a Q.A. manual in design; sophisticated test procedures and facilities; simplicity of design with high accuracy in production; provision of a clear operational maintenance manual, etc. The manufacturers agreed on the need to make a conscious commitment to design for high availability, taking into account both initial and ongoing operating costs in life cycle cost assessment. Predictability, reliability, maintainability, efficiency, market acceptability and maintenance support based on high quality feedback between operator and supplier were all stressed on the grounds that prevention is always better than cure

  10. 75 FR 78715 - Small Entity Compliance Guide: Current Good Manufacturing Practice in Manufacturing, Packaging...

    Science.gov (United States)

    2010-12-16

    ...] Small Entity Compliance Guide: Current Good Manufacturing Practice in Manufacturing, Packaging, Labeling... guidance entitled ``Current Good Manufacturing Practice in Manufacturing, Packaging, Labeling, or Holding... Good Manufacturing Practice in Manufacturing, Packaging, Labeling, or Holding Operations for Dietary...

  11. Connecting American Manufacturers (CAM)

    Science.gov (United States)

    2013-09-01

    to evaluate manufacturing variability as it relates to overall engine performance, whereas General Electric Aviation focused on airflow efficiency...VOICe 467 Total Number of Unique Opportunities scraped from FBO 168,674 Number of Opportunities matched to suppliers in America’s VOICe 90,534...like America’s VOICe matching service to solicitations from FBO and DIBBS as we receive this in our inbox daily which are matched to our

  12. Advanced manufacturing: Technology diffusion

    Energy Technology Data Exchange (ETDEWEB)

    Tesar, A.

    1995-12-01

    In this paper we examine how manufacturing technology diffuses rom the developers of technology across national borders to those who do not have the capability or resources to develop advanced technology on their own. None of the wide variety of technology diffusion mechanisms discussed in this paper are new, yet the opportunities to apply these mechanisms are growing. A dramatic increase in technology diffusion occurred over the last decade. The two major trends which probably drive this increase are a worldwide inclination towards ``freer`` markets and diminishing isolation. Technology is most rapidly diffusing from the US In fact, the US is supplying technology for the rest of the world. The value of the technology supplied by the US more than doubled from 1985 to 1992 (see the Introduction for details). History shows us that technology diffusion is inevitable. It is the rates at which technologies diffuse to other countries which can vary considerably. Manufacturers in these countries are increasingly able to absorb technology. Their manufacturing efficiency is expected to progress as technology becomes increasingly available and utilized.

  13. Safe food manufacturing.

    Science.gov (United States)

    Shapiro, A; Mercier, C

    1994-03-31

    Food safety is a growing preoccupation of the health authorities and the major food companies in any European country. All the aspects of food manufacturing, from the raw materials until the product is consumed have to insure they are innoxious to human health, eliminate any harmful effects related either to food handling or consumption in domestic or common eating places, as well as protect, as much as possible, our environment. Thus, the food manufacturer has to examine step-by-step the security of the agro-cultures, their composition, but also the possible residues of pollutants and contaminants, or chemicals used to protect them against various pests and determine the possible loss or retention of these substances during technological processes. Animal raw materials should not contain veterinary drug residues or an abnormal amount of some components that result from inadequate feeding. Care should be taken to ensure the security of foods manufactured by biotechnology processes. The organisms and the whole processes used in food biotechnologies should eliminate any impurities. Any minor food ingredients, such as food additives, are under a permanent revision from the point of view of their safety. The industry reacts immediately if any justification requires that a particular food additive should not be used. In other words all the raw materials must conform to their specifications. Technological processes must create a food with an adequate microbiological quality, e.g. free of pathogens and their toxic metabolites. Any danger of microbiological contamination or accidental pollution, such as mechanical particles, chemical substances, etc. should be eliminated. The particular role of food packaging is crucial, since this is a barrier to protect the food against further parasites or microbial contamination and preserve the food from alterations due to enzymatic reactions that require particular oxygen and water activity conditions. The packaging should also

  14. 75 FR 80040 - Manufacturing Council

    Science.gov (United States)

    2010-12-21

    ..., developing and marketing programs in support of manufacturing industries, job creation in the manufacturing... relevant contact information such as mailing address, fax, e-mail, fixed and mobile phone numbers and...

  15. Manufacturing a Superconductor in School.

    Science.gov (United States)

    Barrow, John

    1989-01-01

    Described is the manufacture of a superconductor from a commercially available kit using equipment usually available in schools or easily obtainable. The construction is described in detail including equipment, materials, safety procedures, tolerances, and manufacture. (Author/CW)

  16. Green Manufacturing Fundamentals and Applications

    CERN Document Server

    2013-01-01

    Green Manufacturing: Fundamentals and Applications introduces the basic definitions and issues surrounding green manufacturing at the process, machine and system (including supply chain) levels. It also shows, by way of several examples from different industry sectors, the potential for substantial improvement and the paths to achieve the improvement. Additionally, this book discusses regulatory and government motivations for green manufacturing and outlines the path for making manufacturing more green as well as making production more sustainable. This book also: • Discusses new engineering approaches for manufacturing and provides a path from traditional manufacturing to green manufacturing • Addresses regulatory and economic issues surrounding green manufacturing • Details new supply chains that need to be in place before going green • Includes state-of-the-art case studies in the areas of automotive, semiconductor and medical areas as well as in the supply chain and packaging areas Green Manufactu...

  17. Manufacturing mobility in global operations

    NARCIS (Netherlands)

    Steenhuis, H.J.; de Bruijn, E.J.

    2002-01-01

    The globalization trend inevitably affects the organization of manufacturing by enterprises. It offers opportunities to examine manufacturing from a global perspective and consequently to produce where it is most appropriate. However, globalization has also led to an increase in competitive

  18. Composites Manufacturing Education and Technology Facility Expedites Manufacturing Innovation

    Energy Technology Data Exchange (ETDEWEB)

    2017-01-01

    The Composites Manufacturing Education and Technology facility (CoMET) at the National Wind Technology Center at the National Renewable Energy Laboratory (NREL) paves the way for innovative wind turbine components and accelerated manufacturing. Available for use by industry partners and university researchers, the 10,000-square-foot facility expands NREL's composite manufacturing research capabilities by enabling researchers to design, prototype, and test composite wind turbine blades and other components -- and then manufacture them onsite. Designed to work in conjunction with NREL's design, analysis, and structural testing capabilities, the CoMET facility expedites manufacturing innovation.

  19. Exploring manufacturing solutions for SMEs

    DEFF Research Database (Denmark)

    Radziwon, Agnieszka; Blichfeldt, Henrik; Bilberg, Arne

    This exploratory study provides an overview over current state of manufacturing solutions in small and medium sized enterprises (SMEs) in region of Southern Denmark. Building on manufacturing paradigms, this paper reveals relevant aspects for the development and implementation of improving SMEs...... of manufacturing solutions, which are required to increase their competitiveness and assure sustainable growth....

  20. A new colorimetric DPPH•scavenging activity method with no need for a spectrophotometer applied on synthetic and natural antioxidants and medicinal herbs.

    Science.gov (United States)

    Akar, Zeynep; Küçük, Murat; Doğan, Hacer

    2017-12-01

    2,2-Diphenyl-1-picrylhydrazyl (DPPH • ) radical scavenging, the most commonly used antioxidant method with more than seventeen thousand articles cited, is very practical; however, as with most assays, it has the major disadvantage of dependence on a spectrophotometer. To overcome this drawback, the colorimetric determination of the antioxidant activity using a scanner and freely available Image J software was developed. In this new method, the mixtures of solutions of DPPH • and standard antioxidants or extracts of common medicinal herbs were dropped onto TLC plates, after an incubation period. The spot images were evaluated with Image J software to determine CSC 50 values, the sample concentrations providing 50% colour reduction, which were very similar with the SC 50 values obtained with spectrophotometric method. The advantages of the new method are the use of lower amounts of reagents and solvents, no need for costly spectrophotometers, and thus significantly lowered costs, and convenient implementation in any environment and situation.

  1. The Utilization of Nitrogen Gas as a Carrier Gas in the Determination of Hg Ions Using Cold Vapor-Atomic Absorption Spectrophotometer (CV-AAS)

    OpenAIRE

    Panggabean, Aman Sentosa; Pasaribu, Subur P; Kristiana, Farida

    2018-01-01

    The research about utilization of nitrogen gas as a carrier gas in the determination of Hg ions by using Cold Vapor-Atomic Absorption Spectrophotometer (CV-AAS) method has been conducted. To optimize the measurement results, several parameters that affect hydride generator have been studied. Some specified important parameters are SnCl2 concentration as reductant, acid concentration, and the analytical performance such as repeatability and reproducibility (% RSD), linearity (r), limits of det...

  2. A new on-axis micro-spectrophotometer for combining Raman, fluorescence and UV/Vis absorption spectroscopy with macromolecular crystallography at the Swiss Light Source

    OpenAIRE

    Pompidor, Guillaume; Dworkowski, Florian S. N.; Thominet, Vincent; Schulze-Briese, Clemens; Fuchs, Martin R.

    2013-01-01

    The combination of X-ray diffraction experiments with optical methods such as Raman, UV/Vis absorption and fluorescence spectroscopy greatly enhances and complements the specificity of the obtained information. The upgraded version of the in situ on-axis micro-spectrophotometer, MS2, at the macromolecular crystallography beamline X10SA of the Swiss Light Source is presented. The instrument newly supports Raman and resonance Raman spectroscopy, in addition to the previously available UV/Vis ab...

  3. Manufacturing halal in Malaysia

    DEFF Research Database (Denmark)

    Fischer, Johan

    2016-01-01

    production, trade and consumption. Based on fieldwork in Malaysia, this article explores how manufacturing companies understand and practise halal certification, standards and technoscience. I argue that while existing studies of halal overwhelmingly explore micro-social aspects such as the everyday......In Arabic, halal literally means ‘permissible’ or ‘lawful’. Halal is no longer an expression of an esoteric form of production, trade and consumption, but part of a huge and expanding globalized market in which certification, standards and technoscience play important roles. Over the past three...

  4. Good manufacturing practice

    International Nuclear Information System (INIS)

    Schlyer, D.J.

    2001-01-01

    In this presentation author deals with the Implementation of good manufacturing practice for radiopharmaceuticals. The presentation is divided into next parts: Batch size; Expiration date; QC Testing; Environmental concerns; Personnel aspects; Radiation concerns; Theoretical yields; Sterilizing filters; Control and reconciliation of materials and components; Product strength; In process sampling and testing; Holding and distribution; Drug product inspection; Buildings and facilities; Renovations at BNL for GMP; Aseptic processing and sterility assurance; Process validation and control; Quality control and drug product stability; Documentation and other GMP topics; Building design considerations; Equipment; and Summary

  5. Metal Additive Manufacturing: A Review

    Science.gov (United States)

    Frazier, William E.

    2014-06-01

    This paper reviews the state-of-the-art of an important, rapidly emerging, manufacturing technology that is alternatively called additive manufacturing (AM), direct digital manufacturing, free form fabrication, or 3D printing, etc. A broad contextual overview of metallic AM is provided. AM has the potential to revolutionize the global parts manufacturing and logistics landscape. It enables distributed manufacturing and the productions of parts-on-demand while offering the potential to reduce cost, energy consumption, and carbon footprint. This paper explores the material science, processes, and business consideration associated with achieving these performance gains. It is concluded that a paradigm shift is required in order to fully exploit AM potential.

  6. Image-based ELISA on an activated polypropylene microtest plate--a spectrophotometer-free low cost assay technique.

    Science.gov (United States)

    Parween, Shahila; Nahar, Pradip

    2013-10-15

    In this communication, we report ELISA technique on an activated polypropylene microtest plate (APPµTP) as an illustrative example of a low cost diagnostic assay. Activated test zone in APPµTP binds a capture biomolecule through covalent linkage thereby, eliminating non-specific binding often prevalent in absorption based techniques. Efficacy of APPµTP is demonstrated by detecting human immunoglobulin G (IgG), human immunoglobulin E (IgE) and Aspergillus fumigatus antibody in patient's sera. Detection is done by taking the image of the assay solution by a desktop scanner and analyzing the color of the image. Human IgE quantification by color saturation in the image-based assay shows excellent correlation with absorbance-based assay (Pearson correlation coefficient, r=0.992). Significance of the relationship is seen from its p value which is 4.087e-11. Performance of APPµTP is also checked with respect to microtiter plate and paper-based ELISA. APPµTP can quantify an analyte as precisely as in microtiter plate with insignificant non-specific binding, a necessary prerequisite for ELISA assay. In contrast, paper-ELISA shows high non-specific binding in control sera (false positive). Finally, we have carried out ELISA steps on APPµTP by ultrasound waves on a sonicator bath and the results show that even in 8 min, it can convincingly differentiate a test sample from a control sample. In short, spectrophotometer-free image-based miniaturized ELISA on APPµTP is precise, reliable, rapid, and sensitive and could be a good substitute for conventional immunoassay procedures widely used in clinical and research laboratories. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. An in-line spectrophotometer on a centrifugal microfluidic platform for real-time protein determination and calibration.

    Science.gov (United States)

    Ding, Zhaoxiong; Zhang, Dongying; Wang, Guanghui; Tang, Minghui; Dong, Yumin; Zhang, Yixin; Ho, Ho-Pui; Zhang, Xuping

    2016-09-21

    In this paper, an in-line, low-cost, miniature and portable spectrophotometric detection system is presented and used for fast protein determination and calibration in centrifugal microfluidics. Our portable detection system is configured with paired emitter and detector diodes (PEDD), where the light beam between both LEDs is collimated with enhanced system tolerance. It is the first time that a physical model of PEDD is clearly presented, which could be modelled as a photosensitive RC oscillator. A portable centrifugal microfluidic system that contains a wireless port in real-time communication with a smartphone has been built to show that PEDD is an effective strategy for conducting rapid protein bioassays with detection performance comparable to that of a UV-vis spectrophotometer. The choice of centrifugal microfluidics offers the unique benefits of highly parallel fluidic actuation at high accuracy while there is no need for a pump, as inertial forces are present within the entire spinning disc and accurately controlled by varying the spinning speed. As a demonstration experiment, we have conducted the Bradford assay for bovine serum albumin (BSA) concentration calibration from 0 to 2 mg mL(-1). Moreover, a novel centrifugal disc with a spiral microchannel is proposed for automatic distribution and metering of the sample to all the parallel reactions at one time. The reported lab-on-a-disc scheme with PEDD detection may offer a solution for high-throughput assays, such as protein density calibration, drug screening and drug solubility measurement that require the handling of a large number of reactions in parallel.

  8. Improved fiberoptic spectrophotometer

    Science.gov (United States)

    Tans, P.P.; Lashof, D.A.

    1985-04-02

    The present invention allows for accurate spectrophotmetric comparison of the Raman scattering from a sample gas with the Raman scattering from a known gas via a novel fiber optic network. The need for complicated electronic of optical circuit balancing, control, or error compensation circuitry is eliminated. The laser cavity is split into two regions, one of which houses the plasma discharge and produces laser power, and the other of which is adapted to house tubes containing the gas samples. Light from the laser source is beamed simultaneously through samples of the reference gas and the unknown gas, and Raman-scattered light is emitted. The Raman-scattered light from the known and unknown mixtures is then alternately passed through a fiber optic network where the various wavelengths are spatially mixed. The mixed light is then passed into a system of light detectors, each of which are adapted to measure one of the wavelengths of light representing a constituent element of the gases. When the test is complete, each gas sample can be assigned a Raman-scattered profile from the data consisting of the ratios each of the constituent elements bear to each other. (LEW)

  9. Cloud manufacturing distributed computing technologies for global and sustainable manufacturing

    CERN Document Server

    Mehnen, Jörn

    2013-01-01

    Global networks, which are the primary pillars of the modern manufacturing industry and supply chains, can only cope with the new challenges, requirements and demands when supported by new computing and Internet-based technologies. Cloud Manufacturing: Distributed Computing Technologies for Global and Sustainable Manufacturing introduces a new paradigm for scalable service-oriented sustainable and globally distributed manufacturing systems.   The eleven chapters in this book provide an updated overview of the latest technological development and applications in relevant research areas.  Following an introduction to the essential features of Cloud Computing, chapters cover a range of methods and applications such as the factors that actually affect adoption of the Cloud Computing technology in manufacturing companies and new geometrical simplification method to stream 3-Dimensional design and manufacturing data via the Internet. This is further supported case studies and real life data for Waste Electrical ...

  10. Manufacture of Probiotic Bacteria

    Science.gov (United States)

    Muller, J. A.; Ross, R. P.; Fitzgerald, G. F.; Stanton, C.

    Lactic acid bacteria (LAB) have been used for many years as natural biopreservatives in fermented foods. A small group of LAB are also believed to have beneficial health effects on the host, so called probiotic bacteria. Probiotics have emerged from the niche industry from Asia into European and American markets. Functional foods are one of the fastest growing markets today, with estimated growth to 20 billion dollars worldwide by 2010 (GIA, 2008). The increasing demand for probiotics and the new food markets where probiotics are introduced, challenges the industry to produce high quantities of probiotic cultures in a viable and stable form. Dried concentrated probiotic cultures are the most convenient form for incorporation into functional foods, given the ease of storage, handling and transport, especially for shelf-stable functional products. This chapter will discuss various aspects of the challenges associated with the manufacturing of probiotic cultures.

  11. Maintenance in sustainable manufacturing

    Directory of Open Access Journals (Sweden)

    Vladimir Stuchly

    2014-09-01

    Full Text Available Background: Sustainable development is about reaching a balance between economic, social, and environmental goals, as well as people's participation in the planning process in order to gain their input and support. For a company, sustainable development means adoption of such business strategy and actions that contribute to satisfying present needs of company and stakeholders, as well as simultaneous protection, maintenance and strengthening of human and environmental potential which will be needed in the future. This new approach forces manufacturing companies to change their previous management paradigms. New management paradigm should include new issues and develop innovative methods, practices and technologies striving for solving problem of shortages of resources, softening environment overload and enabling development of environment-friendly lifecycle of products. Hence, its realization requires updating existing production models as they are based on previously accepted paradigm of unlimited resources and unlimited regeneration capabilities. Maintenance plays a crucial role because of its impact on availability, reliability, quality and life cycle cost, thus it should be one of the main pillars of new business running model.  Material and methods: The following paper is a result of research on the literature and observation of practices undertaken by a company within maintenance area. Results and conclusions: The main message is that considering sustainable manufacturing requires considerable expanding range of analysis and focusing on supporting processes. Maintenance offers numerous opportunities of decreasing influence of business processes on natural environment and more efficient resources utilization. The goal of maintenance processes realizing sustainable development strategy is increased profitability of exploitation and optimization of total lifecycle cost without disturbing safety and environmental issues. 

  12. Business models for additive manufacturing

    DEFF Research Database (Denmark)

    Hadar, Ronen; Bilberg, Arne; Bogers, Marcel

    2015-01-01

    a manufacturer-centric to a consumer-centric value logic. A major shift includes a move from centralized to decentralized supply chains, where consumer goods manufacturers can implement a “hybrid” approach with a focus on localization and accessibility or develop a fully personalized model where the consumer...... of creating and capturing value. In this paper, we explore the implications that AM technologies have for manufacturing systems in the new business models that they enable. In particular, we consider how a consumer goods manufacturer can organize the operations of a more open business model when moving from...... effectively takes over the productive activities of the manufacturer. We discuss some of the main implications for research and practice of consumer-centric business models and the changing decoupling point in consumer goods’ manufacturing supply chains....

  13. Manufacturing consumption of energy 1994

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-12-01

    This report provides estimates on energy consumption in the manufacturing sector of the U.S. economy based on data from the Manufacturing Energy Consumption Survey. The sample used in this report represented about 250,000 of the largest manufacturing establishments which account for approximately 98 percent of U.S. economic output from manufacturing, and an expected similar proportion of manufacturing energy use. The amount of energy use was collected for all operations of each establishment surveyed. Highlights of the report include profiles for the four major energy-consuming industries (petroleum refining, chemical, paper, and primary metal industries), and an analysis of the effects of changes in the natural gas and electricity markets on the manufacturing sector. Seven appendices are included to provide detailed background information. 10 figs., 51 tabs.

  14. Support Vector Machine and Artificial Neural Network Models for the Classification of Grapevine Varieties Using a Portable NIR Spectrophotometer

    Science.gov (United States)

    Gutiérrez, Salvador; Tardaguila, Javier; Fernández-Novales, Juan; Diago, María P.

    2015-01-01

    The identification of different grapevine varieties, currently attended using visual ampelometry, DNA analysis and very recently, by hyperspectral analysis under laboratory conditions, is an issue of great importance in the wine industry. This work presents support vector machine and artificial neural network’s modelling for grapevine varietal classification from in-field leaf spectroscopy. Modelling was attempted at two scales: site-specific and a global scale. Spectral measurements were obtained on the near-infrared (NIR) spectral range between 1600 to 2400 nm under field conditions in a non-destructive way using a portable spectrophotometer. For the site specific approach, spectra were collected from the adaxial side of 400 individual leaves of 20 grapevine (Vitis vinifera L.) varieties one week after veraison. For the global model, two additional sets of spectra were collected one week before harvest from two different vineyards in another vintage, each one consisting on 48 measurement from individual leaves of six varieties. Several combinations of spectra scatter correction and smoothing filtering were studied. For the training of the models, support vector machines and artificial neural networks were employed using the pre-processed spectra as input and the varieties as the classes of the models. The results from the pre-processing study showed that there was no influence whether using scatter correction or not. Also, a second-degree derivative with a window size of 5 Savitzky-Golay filtering yielded the highest outcomes. For the site-specific model, with 20 classes, the best results from the classifiers thrown an overall score of 87.25% of correctly classified samples. These results were compared under the same conditions with a model trained using partial least squares discriminant analysis, which showed a worse performance in every case. For the global model, a 6-class dataset involving samples from three different vineyards, two years and leaves

  15. Support Vector Machine and Artificial Neural Network Models for the Classification of Grapevine Varieties Using a Portable NIR Spectrophotometer.

    Science.gov (United States)

    Gutiérrez, Salvador; Tardaguila, Javier; Fernández-Novales, Juan; Diago, María P

    2015-01-01

    The identification of different grapevine varieties, currently attended using visual ampelometry, DNA analysis and very recently, by hyperspectral analysis under laboratory conditions, is an issue of great importance in the wine industry. This work presents support vector machine and artificial neural network's modelling for grapevine varietal classification from in-field leaf spectroscopy. Modelling was attempted at two scales: site-specific and a global scale. Spectral measurements were obtained on the near-infrared (NIR) spectral range between 1600 to 2400 nm under field conditions in a non-destructive way using a portable spectrophotometer. For the site specific approach, spectra were collected from the adaxial side of 400 individual leaves of 20 grapevine (Vitis vinifera L.) varieties one week after veraison. For the global model, two additional sets of spectra were collected one week before harvest from two different vineyards in another vintage, each one consisting on 48 measurement from individual leaves of six varieties. Several combinations of spectra scatter correction and smoothing filtering were studied. For the training of the models, support vector machines and artificial neural networks were employed using the pre-processed spectra as input and the varieties as the classes of the models. The results from the pre-processing study showed that there was no influence whether using scatter correction or not. Also, a second-degree derivative with a window size of 5 Savitzky-Golay filtering yielded the highest outcomes. For the site-specific model, with 20 classes, the best results from the classifiers thrown an overall score of 87.25% of correctly classified samples. These results were compared under the same conditions with a model trained using partial least squares discriminant analysis, which showed a worse performance in every case. For the global model, a 6-class dataset involving samples from three different vineyards, two years and leaves

  16. Wide and High Additive Manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Post, Brian K. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Roschli, Alex C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-03-01

    The goal of this project is to develop and demonstrate the enabling technologies for Wide and High Additive Manufacturing (WHAM). WHAM will open up new areas of U.S. manufacturing for very large tooling in support of the transportation and energy industries, significantly reducing cost and lead time. As with Big Area Additive Manufacturing (BAAM), the initial focus is on the deposition of composite materials.

  17. Manufacturing consumption of energy 1991

    Energy Technology Data Exchange (ETDEWEB)

    1994-12-01

    This report provides estimates on energy consumption in the manufacturing sector of the US economy. These estimates are based on data from the 1991 Manufacturing Energy Consumption Survey (MECS). This survey--administered by the Energy End Use and Integrated Statistics Division, Office of Energy Markets and End Use, Energy Information Administration (EIA)--is the most comprehensive source of national-level data on energy-related information for the manufacturing industries.

  18. Green manufacturing processes and systems

    Energy Technology Data Exchange (ETDEWEB)

    Davim, J. Paulo (ed.) [Aveiro Univ. (Portugal). Dept. of Mechanical Engineering, Campus Universitario de Santiago

    2013-02-01

    This book provides the recent advances on green manufacturing processes and systems for modern industry. Chapter 1 provides information on sustainable manufacturing through environmentally-friendly machining. Chapter 2 is dedicated to environmentally-friendly machining: vegetable based cutting fluids. Chapter 3 describes environmental-friendly joining of tubes. Chapter 4 contains information on concepts, methods and strategies for zero-waste in manufacturing. Finally, chapter 5 is dedicated to the application of hybrid MCDM approach for selecting the best tyre recycling process.

  19. 78 FR 67117 - Manufacturing Council

    Science.gov (United States)

    2013-11-08

    ... States remains the preeminent destination for investment in manufacturing throughout the world'' as..., but not limited to, the candidate's proven experience in promoting, developing and marketing programs...

  20. Advanced manufacturing technologies modern machining, advanced joining, sustainable manufacturing

    CERN Document Server

    2017-01-01

    This book provides details and collective information on working principle, process mechanism, salient features, and unique applications of various advanced manufacturing techniques and processes belong. The book is divided in three sessions covering modern machining methods, advanced repair and joining techniques and, finally, sustainable manufacturing. The latest trends and research aspects of those fields are highlighted.

  1. Manufacturing strategy issues in selected Indian manufacturing industry

    Directory of Open Access Journals (Sweden)

    Mahender Singh

    2013-03-01

    Full Text Available This paper presents some findings of Indian manufacturing sectors viz. automobile (especially two-wheeler, tractor and general manufacturing industry. Various manufacturing strategy issues such as competitive priorities, improvement activities, and performance measures, have been identified and assessed in Indian context. Sector wise comparison of competitive priorities, improvement activities i.e. advanced manufacturing technology (AMT, integrated information systems (IIS, and advanced management systems (AMS, and performance measure, is provided. Our results showed that most of the Indian companies are still emphasizing on quality. However, automobile sector has set to compete globally with high innovation rate, faster new product development, and continuous improvement. It is also observed that Indian companies are investing more in AMS as compared to IIS and AMT. Manufacturing competence index is also computed for each sector.

  2. Additive Manufactured Superconducting Cavities

    Science.gov (United States)

    Holland, Eric; Rosen, Yaniv; Woolleet, Nathan; Materise, Nicholas; Voisin, Thomas; Wang, Morris; Mireles, Jorge; Carosi, Gianpaolo; Dubois, Jonathan

    Superconducting radio frequency cavities provide an ultra-low dissipative environment, which has enabled fundamental investigations in quantum mechanics, materials properties, and the search for new particles in and beyond the standard model. However, resonator designs are constrained by limitations in conventional machining techniques. For example, current through a seam is a limiting factor in performance for many waveguide cavities. Development of highly reproducible methods for metallic parts through additive manufacturing, referred to colloquially as 3D printing\\x9D, opens the possibility for novel cavity designs which cannot be implemented through conventional methods. We present preliminary investigations of superconducting cavities made through a selective laser melting process, which compacts a granular powder via a high-power laser according to a digitally defined geometry. Initial work suggests that assuming a loss model and numerically optimizing a geometry to minimize dissipation results in modest improvements in device performance. Furthermore, a subset of titanium alloys, particularly, a titanium, aluminum, vanadium alloy (Ti - 6Al - 4V) exhibits properties indicative of a high kinetic inductance material. This work is supported by LDRD 16-SI-004.

  3. Balances instruments, manufacturers, history

    CERN Document Server

    Robens, Erich; Kiefer, Susanne

    2014-01-01

    The book deals mainly with direct mass determination by means of a conventional balances. It covers the history of the balance from the beginnings in Egypt earlier than 3000 BC to recent developments. All balance types are described with emphasis on scientific balances. Methods of indirect mass determination, which are applied to very light objects like molecules and the basic particles of matter and celestial bodies, are included.  As additional guidance, today’s manufacturers are listed and the profile of important companies is reviewed. Several hundred photographs, reproductions and drawings show instruments and their uses. This book includes commercial weighing instruments for merchandise and raw materials in workshops as well as symbolic weighing in the ancient Egyptian’s ceremony of ‘Weighing of the Heart’, the Greek fate balance, the Roman  Justitia, Juno Moneta and Middle Ages scenes of the Last Judgement with Jesus or St. Michael and of modern balances. The photographs are selected from the...

  4. Advanced Manufacture of Reflectors

    Energy Technology Data Exchange (ETDEWEB)

    Angel, Roger [Univ. of Arizona, Tucson, AZ (United States)

    2014-12-17

    The main project objective has been to develop an advanced gravity sag method for molding large glass solar reflectors with either line or point focus, and with long or short focal length. The method involves taking standard sized squares of glass, 1.65 m x 1.65 m, and shaping them by gravity sag into precision steel molds. The method is designed for high volume manufacture when incorporated into a production line with separate pre-heating and cooling. The performance objectives for the self-supporting glass mirrors made by this project include mirror optical accuracy of 2 mrad root mean square (RMS), requiring surface slope errors less than 1 mrad rms, a target not met by current production of solar reflectors. Our objective also included development of new methods for rapidly shaping glass mirrors and coating them for higher reflectivity and soil resistance. Reflectivity of 95% for a glass mirror with anti-soil coating was targeted, compared to the present ~94% with no anti-soil coating. Our mirror cost objective is ~$20/m2 in 2020, a significant reduction compared to the present ~$35/m2 for solar trough mirrors produced for trough solar plants.

  5. Calibration Transfer Between a Bench Scanning and a Submersible Diode Array Spectrophotometer for In Situ Wastewater Quality Monitoring in Sewer Systems.

    Science.gov (United States)

    Brito, Rita S; Pinheiro, Helena M; Ferreira, Filipa; Matos, José S; Pinheiro, Alexandre; Lourenço, Nídia D

    2016-03-01

    Online monitoring programs based on spectroscopy have a high application potential for the detection of hazardous wastewater discharges in sewer systems. Wastewater hydraulics poses a challenge for in situ spectroscopy, especially when the system includes storm water connections leading to rapid changes in water depth, velocity, and in the water quality matrix. Thus, there is a need to optimize and fix the location of in situ instruments, limiting their availability for calibration. In this context, the development of calibration models on bench spectrophotometers to estimate wastewater quality parameters from spectra acquired with in situ instruments could be very useful. However, spectra contain information not only from the samples, but also from the spectrophotometer generally invalidating this approach. The use of calibration transfer methods is a promising solution to this problem. In this study, calibration models were developed using interval partial least squares (iPLS), for the estimation of total suspended solids (TSS) and chemical oxygen demand (COD) in sewage from Ultraviolet-visible spectra acquired in a bench scanning spectrophotometer. The feasibility of calibration transfer to a submersible, diode array equipment, to be subsequently operated in situ, was assessed using three procedures: slope and bias correction (SBC); single wavelength standardization (SWS) on mean spectra; and local centering (LC). The results showed that SBC was the most adequate for the available data, adding insignificant error to the base model estimates. Single wavelength standardization was a close second best, potentially more robust, and independent of the base iPLS model. Local centering was shown to be inadequate for the samples and instruments used. © The Author(s) 2016.

  6. In vitro kinetics of P700+reduction of Thermosynechococcus elongatus trimeric Photosystem I complexes by recombinant cytochrome c6using a Joliot-type LED spectrophotometer.

    Science.gov (United States)

    Nguyen, Khoa; Vaughn, Michael; Frymier, Paul; Bruce, Barry D

    2017-01-01

    The reduction rate of photo-oxidized Photosystem I (PSI) with various natural and artificial electron donors have been well studied by transient absorption spectroscopy. The electron transfer rate from various donors to P 700 + has been measured for a wide range of photosynthetic organisms encompassing cyanobacteria, algae, and plants. PSI can be a limiting component due to tedious extraction and purification methods required for this membrane protein. In this report, we have determined the in vivo, intracellular cytochrome c 6 (cyt c 6 )/PSI ratio in Thermosynechococcus elongatus (T.e.) using quantitative Western blot analysis. This information permitted the determination of P 700 + reduction kinetics via recombinant cyt c 6 in a physiologically relevant ratio (cyt c 6 : PSI) with a Joliot-type, LED-driven, pump-probe spectrophotometer. Dilute PSI samples were tested under varying cyt c 6 concentration, temperature, pH, and ionic strength, each of which shows similar trends to the reported literature utilizing much higher PSI concentrations with laser-based spectrophotometer. Our results do however indicate kinetic differences between actinic light sources (laser vs. LED), and we have attempted to resolve these effects by varying our LED light intensity and duration. The standardized configuration of this spectrophotometer will also allow a more uniform kinetic analysis of samples in different laboratories. We can conclude that our findings from the LED-based system display an added total protein concentration effect due to multiple turnover events of P 700 + reduction by cyt c 6 during the longer illumination regime.

  7. 77 FR 56811 - Manufacturing Council

    Science.gov (United States)

    2012-09-14

    ... other stakeholders to increase the global competitiveness of the U.S. manufacturing sector. ADDRESSES... of responsibility) that are leaders within their local manufacturing communities and industry sectors... controlled by U.S. citizens or by another U.S. entity. An entity is not a U.S. entity if 50 percent plus one...

  8. 76 FR 33244 - Manufacturing Council

    Science.gov (United States)

    2011-06-08

    ... indirectly, by non- U.S. citizens or non-U.S. entities. Appointments to the Council will be made by the... DEPARTMENT OF COMMERCE International Trade Administration Manufacturing Council AGENCY... Membership on the Manufacturing Council. SUMMARY: The Department of Commerce is currently seeking...

  9. 77 FR 2275 - Manufacturing Council

    Science.gov (United States)

    2012-01-17

    ..., directly or indirectly, by non- U.S. citizens or non-U.S. entities. Appointments to the Council will be... DEPARTMENT OF COMMERCE International Trade Administration Manufacturing Council AGENCY... membership on the Manufacturing Council. SUMMARY: The Department of Commerce is currently seeking...

  10. Solar array manufacturing industry simulation

    Science.gov (United States)

    Chamberlain, R. G.; Firnett, P. J.; Kleine, B.

    1980-01-01

    Solar Array Manufacturing Industry Simulation (SAMIS) program is a standardized model of industry to manufacture silicon solar modules for use in electricity generation. Model is used to develop financial reports that detail requirements, including amounts and prices for materials, labor, facilities, and equipment required by companies.

  11. Graphical simulation for aerospace manufacturing

    Science.gov (United States)

    Babai, Majid; Bien, Christopher

    1994-01-01

    Simulation software has become a key technological enabler for integrating flexible manufacturing systems and streamlining the overall aerospace manufacturing process. In particular, robot simulation and offline programming software is being credited for reducing down time and labor cost, while boosting quality and significantly increasing productivity.

  12. High power lasers in manufacturing

    OpenAIRE

    Chatwin, Chris R

    2017-01-01

    Lecture covers a brief history of lasers and the important beam parameters for manufacturing applications. It introduces the main laser types that are appropriate for manufacturing: carbon dioxide lasers, Nd YAG, Diode and fibre lasers, excimer lasers. It then looks at applications to different products and also micro-engineering

  13. Job Prospects for Manufacturing Engineers.

    Science.gov (United States)

    Basta, Nicholas

    1985-01-01

    Coming from a variety of disciplines, manufacturing engineers are keys to industry's efforts to modernize, with demand exceeding supply. The newest and fastest-growing areas include machine vision, composite materials, and manufacturing automation protocols, each of which is briefly discussed. (JN)

  14. Manufacturing best practices and performance

    DEFF Research Database (Denmark)

    Szász, Levente; Demeter, Krisztina; Boer, Harry

    2014-01-01

    analysis is used to develop groups of companies based on home and host country development. Exploratory factor analysis is applied to create bundles of manufacturing practices and performance measures. Then, using moderated multiple regressions (MMR) with interaction factor, and separate multiple...... regression analyses for each group of companies, bundles of manufacturing practices are identified that lead to best-in-class performance improvements. A range of control variables is introduced to help interpret the results. The study shows that home and host country context does affect the association...... whether a) home and host country characteristics moderate the association between manufacturing practices and performance, and, thus, whether b) there are manufacturing practices that are universally best. Manufacturing practices and performance are measured using data collected through the fifth round...

  15. Comparative Study of the Gross Interpretation of Phototesting and Objective Measurement with Using a Spectrophotometer for Patients with Psoriasis and Vitiligo Treated with Narrow-band UVB

    Science.gov (United States)

    Choi, Kyu-Won; Kim, Ki-Ho

    2009-01-01

    Background Determination of the minimal erythema dose (MED) is important for developing a phototherapy protocol and to diagnosis photosensitivity disorders. But obtaining a precise and reproducible MED is quite difficult because a phototest for erythema is based on subjective assessment. Objective The objective of our study was to compare the gross interpretation of a phototest and the objective measurement using a spectrophotometer for determining the parameters of cutaneous narrow-band UVB (NBUVB) therapy. Methods A total of 14 psoriasis and 10 vitiligo patients who receiving NBUVB phototherapy with skin types III and IV were selected for this study. To perform phototesting, ten sites on the skin of the back were vertically exposed to a series of 10 NBUVB doses among 14 doses between 340 and 1,400 mJ/cm2. We interpreted the gross findings of erythema and measured the L*a*b* values with using a spectrophotometer at each phototest spot and at the control skin. Also, we evaluate the relationship between the gross presentation and the spectrophotometric analysis by delta E for the assessment of the minimal perceptible erythema (MPE) and MED. Results For all the subjects, the MEDs were measured in the 490~1,000 mJ/cm2 range. The average of the colorimetric values for the control skin were L*: 64.8, a*: 7.9 and b*: 19.8. Among them, the L* value and MED value were shown to be inversely correlated, and as the L* value was decreased, the MED was increased. For the MPE, the delta E, which was the color difference of the normal skin and the phototest area, was within the range of 1.5~3.0 in 17 of the 21 patients, and 4 patients were within the range of 1.0~1.5. For the MED, among the 21 patients, the delta E of 17 patients was within the range of 3.0~6.0, and 4 patients were within the range of 6.0~12.0. Conclusion A spectrophotometer enables UV erythema to be assessed objectively and quantitatively, and this can compensate for the disadvantages of subjective gross

  16. Comparative Study of the Gross Interpretation of Phototesting and Objective Measurement with Using a Spectrophotometer for Patients with Psoriasis and Vitiligo Treated with Narrow-band UVB.

    Science.gov (United States)

    Choi, Kyu-Won; Kim, Ki-Ho; Kim, Young-Hun

    2009-05-01

    Determination of the minimal erythema dose (MED) is important for developing a phototherapy protocol and to diagnosis photosensitivity disorders. But obtaining a precise and reproducible MED is quite difficult because a phototest for erythema is based on subjective assessment. The objective of our study was to compare the gross interpretation of a phototest and the objective measurement using a spectrophotometer for determining the parameters of cutaneous narrow-band UVB (NBUVB) therapy. A total of 14 psoriasis and 10 vitiligo patients who receiving NBUVB phototherapy with skin types III and IV were selected for this study. To perform phototesting, ten sites on the skin of the back were vertically exposed to a series of 10 NBUVB doses among 14 doses between 340 and 1,400 mJ/cm(2). We interpreted the gross findings of erythema and measured the L*a*b* values with using a spectrophotometer at each phototest spot and at the control skin. Also, we evaluate the relationship between the gross presentation and the spectrophotometric analysis by delta E for the assessment of the minimal perceptible erythema (MPE) and MED. For all the subjects, the MEDs were measured in the 490~1,000 mJ/cm(2) range. The average of the colorimetric values for the control skin were L*: 64.8, a*: 7.9 and b*: 19.8. Among them, the L* value and MED value were shown to be inversely correlated, and as the L* value was decreased, the MED was increased. For the MPE, the delta E, which was the color difference of the normal skin and the phototest area, was within the range of 1.5~3.0 in 17 of the 21 patients, and 4 patients were within the range of 1.0~1.5. For the MED, among the 21 patients, the delta E of 17 patients was within the range of 3.0~6.0, and 4 patients were within the range of 6.0~12.0. A spectrophotometer enables UV erythema to be assessed objectively and quantitatively, and this can compensate for the disadvantages of subjective gross interpretation when determining the MED. Delta E is

  17. Advanced Manufacturing Technologies (AMT): Modular Rapidly Manufactured SmallSat

    Data.gov (United States)

    National Aeronautics and Space Administration — Utilize advanced manufacturing processes to design and fabricate a fully functional prototype flight model, with the goal of demonstrating rapid on-orbit assembly of...

  18. Integrated Glass Coating Manufacturing Line

    Energy Technology Data Exchange (ETDEWEB)

    Brophy, Brenor [Enki Technology Inc., San Jose, CA (United States)

    2015-09-30

    This project aims to enable US module manufacturers to coat glass with Enki’s state of the art tunable functionalized AR coatings at the lowest possible cost and highest possible performance by encapsulating Enki’s coating process in an integrated tool that facilitates effective process improvement through metrology and data analysis for greater quality and performance while reducing footprint, operating and capital costs. The Phase 1 objective was a fully designed manufacturing line, including fully specified equipment ready for issue of purchase requisitions; a detailed economic justification based on market prices at the end of Phase 1 and projected manufacturing costs and a detailed deployment plan for the equipment.

  19. Molded optics design and manufacture

    CERN Document Server

    Schaub, Michael

    2007-01-01

    While several available texts discuss molded plastic optics, none provide information on all classes of molded optics. Filling this gap, Molded Optics: Design and Manufacture presents detailed descriptions of molded plastic, glass, and infrared optics. Since an understanding of the manufacturing process is necessary to develop cost-effective, producible designs, the book extensively covers various manufacturing methods, design guidelines, trade-offs, best practices, and testing of critical parameters. It also discusses topics that often arise when designing systems with molded optics, such as

  20. Micro manufacturing techniques and applications

    CERN Document Server

    Du, Ruxu; Li, Zifu

    2013-01-01

    Micro/meso-scale manufacturing has been developed in research fields of machining, forming, materials and others, but its potential to industries are yet to be fully realized. The theme of the current volume was to build a bridge joining academic research and industrial needs in micro manufacturing. Among the 12 papers selected for publication are three keynote addresses onmicro and desktop factories for micro/meso-scale manufacturing applicationsand future visions, tissue cutting mechanics and applications for needlecore biopsy and guidance, and micro-texturing onto amorphous carbonmaterials

  1. Study on chromium (VI) reduction kinetics by Pseudomonas aeruginosa using a combined system of acoustic wave impedance analyzer and UV-vis spectrophotometer.

    Science.gov (United States)

    Li, Xuefang; Wei, Wanzhi; Zeng, Xiandong; He, Deliang; Yin, Jian; Zeng, Jinxiang; Wu, Ling

    2006-09-01

    A novel system combining acoustic wave impedance (AWI) analyzer with UV-vis spectrophotometer was developed for the study of chromium (VI) reduction kinetics by Pseudomonas aeruginosa. AWI gave information about the growth of Pseudomonas aeruginosa, and UV-vis spectrophotometer gave information about the concentration of chromium (VI) simultaneously. A combined system response model, for chromium (VI) reduction kinetics at lower initial chromium (VI) concentrations, was derived and proved based on the novel system. Taking into account the effect of bacterial growth on chromium (VI) reduction, the new model successfully simulated chromium (VI) bioremediation process. By fitting chromium (VI) reduction data toward the derived model, the kinetic parameters related to the process were obtained. When the concentration of peptone was 10 g L(-1), the half-velocity reduction rate constant K (C) and the maximum specific chromium (VI) reduction rate constant nu(max) were 0.7682 mg chromium (VI) L(-1) and 2.5814 x 10(-12) mg chromium (VI) cells(-1) h(-1), respectively. It was found that the combined system can provide real-time, reliable, and two-dimensional kinetic information, and can be applied to study other biological processes.

  2. Versatile spectrophotometer for photosynthesis (light-induced changes in absorbance and fluorescence yield, circular and linear dichroism) and other biophysical measurements

    Science.gov (United States)

    Ke, Bacon; Breeze, Robert H.; Dolan, Edward; Vore, Duane

    1985-01-01

    The construction of a versatile, single-beam spectrophotometer expanded from a previously reported circular dichrometer utilizing an elasto-optic modulator (EOM) for producing circular polarization, is described. The new spectrophotometer is capable of measuring circular dichroism as well as linear dichroism and light-induced changes in absorbance and fluorescence yield, the latter being two of the most commonly measured properties in photosynthesis research. The use of an EOM, along with a phase-sensitive detector, affords high sensitivity and at the same time, in conjuction with a mechanical phosphoroscopic device, a high degree of immunity from artifacts in studies employing actinic light. A description is given of the generation and use of timing signals essential for control and signal processing. Its performance is illustrated by examples drawn from light-induced absorbance and fluorescence-yield changes associated with photosynthetic electron transport and changes in redox state of electron carriers. This photometer, with very little modification, may also be used to perform a host of other types of measurements.

  3. [The study of the colorimetric characteristics of the cobalt-chrome alloys abutments covered by four different all-ceramic crowns by using dental spectrophotometer].

    Science.gov (United States)

    Chen, Yifan; Liu, Hongchun; Meng, Yukun; Chao, Yonglie; Liu, Changhong

    2015-06-01

    This study aims to evaluate the optical data of the different sites of the cobalt-chrome (Co-Cr) alloy abutments covered by four different all-ceramic crowns and the color difference between the crowns and target tab using a digital dental spectrophotometer. Ten Co-Cr alloy abutments were made and tried in four different groups of all-ceramic crowns, namely, Procera aluminia, Procera zirconia, Lava zirconia (Lava-Zir), and IPS E.max glass-ceramic lithium disilicate-reinforced monolithic. The color data of the cervical, body, and incisal sites of the samples were recorded and analyzed by dental spectrophotometer. The CIE L*, a*, b* values were again measured after veneering. The color difference between the abutments covered by all-ceramic crowns and A2 dentine shade tab was evaluated. The L* and b* values of the abutments can be increased by all of the four groups of all-ceramic copings, but a* values were decreased in most groups. A statistical difference was observed among four groups. After being veneered, the L* values of all the copings declined slightly, and the values of a*, b* increased significantly. When compared with A2 dentine shade tab, the ΔE of the crowns was below 4. Four ceramic copings were demonstrated to promote the lightness and hue of the alloy abutments effecttively. Though the colorimetric baseline of these copings was uneven, veneer porcelain can efficiently decrease the color difference between the samples and thee target.

  4. Protoporphyrin IX induced by 5-aminolevulinic acid in bladder cancer cells in voided urine can be extracorporeally quantified using a spectrophotometer.

    Science.gov (United States)

    Nakai, Yasushi; Anai, Satoshi; Onishi, Sayuri; Masaomi, Kuwada; Tatsumi, Yoshihiro; Miyake, Makito; Chihara, Yoshitomo; Tanaka, Nobumichi; Hirao, Yoshihiko; Fujimoto, Kiyohide

    2015-06-01

    We evaluated the feasibility of photodynamic diagnosis of bladder cancer by spectrophotometric analysis of voided urine samples after extracorporeal treatment with 5-aminolevulinic acid (ALA). Sixty-one patients with bladder cancer, confirmed histologically after the transurethral resection of a bladder tumor, were recruited as the bladder cancer group, and 50 outpatients without history of urothelial carcinoma or cancer-related findings were recruited as the control group. Half of the voided urine sample was incubated with ALA (ALA-treated sample), and the rest was incubated without treatment (ALA-untreated sample). For detecting cellular protoporphyrin IX levels, intensity of the samples at the excitation wavelength of 405 nm was measured using a spectrophotometer. The difference between the intensity of the ALA-treated and ALA-untreated samples at 635 nm was calculated. The differences in the bladder cancer group were significantly greater than those in the control group (p spectrophotometer in patients with bladder cancer. Therefore, this cancer detection system has a potential for clinical use. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Paradigms for environmentally conscious manufacturing

    Science.gov (United States)

    Edinbarough, Immanuel A.; Wells, Wayne E.

    2004-12-01

    There are several stories involving the industries that pledge themselves for the environmentally conscious manufacturing practices. Paradigms for environmentally conscious manufacturing are associated with one of the aspects of environmental quality, protection, resource management, commitment or sustainability. The engineering rules of thumb that can easily be adopted by aspiring companies need identification. The underlying thread that unifies the efforts of environmentally conscious manufacturing companies, in offering the environmentally safe products to the world, is grouped and presented in the paper as paradigms for successful practices. The various ways in which a start up company, that wants to excel in environmentally conscious manufacturing, can position itself based on the paradigms is also discussed in the paper.

  6. Many Manufactured Nanosats, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — To achieve the capability to affordably produce scores of nano-spacecraft for envisioned constellation missions, a new manufacturing process is needed to reduce the...

  7. Nested Material Manufacturing Technology Improvement

    National Research Council Canada - National Science Library

    2008-01-01

    The objective of this project was to develop an automated planning and control system in the GD NASSCO Pipe Shop that enabled the efficient handling of pipe spool fabrication in a flexible manufacturing environment...

  8. Attracting young talents to manufacturing

    DEFF Research Database (Denmark)

    Perini, Stefano; Oliveira, Manuel; Costa, Joao

    2014-01-01

    In the last years, despite the global economic crisis, manufacturing is facing a serious difficulty in the recruitment of the brightest high-skilled human resources. National and international institutions have provided important guidelines to combat this skills mismatch and several innovations...... have been made both in STEM and manufacturing education. However, there is still a lack of concrete strategies harmonizing together delivery mechanisms and pedagogical frameworks throughout the whole student lifecycle. In order to mitigate these urgent needs, ManuSkills innovative approach provides...... a strong integrated strategy towards attracting young talent to manufacturing, by raising the aware-ness and providing the acquisition of new manufacturing skills. The key-concepts and the strategy to achieve learning objectives are presented. Finally, ManuSkills Five Pillars, i.e. Interaction...

  9. Controlled Hierarchical Structure Additive Manufacturing

    Data.gov (United States)

    National Aeronautics and Space Administration — Additive manufacturing methods (e.g. direct-write, stereolithography (SLA), etc.) will be used to place living organisms (e.g. bacteria, diatoms, etc.) at desired...

  10. Wood and Paper Manufacturing Sectors

    Science.gov (United States)

    Find EPA regulatory information for the wood product and paper manufacturing sectors, including paper, pulp and lumber. Information includes NESHAPs and effluent guidelines for pulp and paper rulemaking, and compliance guidelines

  11. 75 FR 30781 - Manufacturing Council

    Science.gov (United States)

    2010-06-02

    ... Commerce's International Trade Administration published a notice in the Federal Register (75 FR 12507... DEPARTMENT OF COMMERCE International Trade Administration Manufacturing Council AGENCY: International Trade Administration, U.S. Department of Commerce. ACTION: Notice of Reopening of the Application...

  12. 77 FR 66179 - Manufacturing Council

    Science.gov (United States)

    2012-11-02

    ... Commerce's International Trade Administration published a notice in the Federal Register (77 FR 56811... DEPARTMENT OF COMMERCE International Trade Administration Manufacturing Council AGENCY: International Trade Administration, U.S. Department of Commerce. ACTION: Notice of extension of the application...

  13. Nano Manufacturing - Products and Technologies

    DEFF Research Database (Denmark)

    Hansen, Hans Nørgaard; Alting, Leo

    2004-01-01

    The use of micro and nano technologies in components and products not only sets new demands to the manufacturing technologies. Product concepts have to be rethought and redefined in order to implement the micro and nano technologies into functional systems. Both a technology driven and a product...... driven approach can be used in this process. A framework for the product driven approach in nano manufacturing is presented and discussed. The general discussion will be supported by case studies covering polymers and metals....

  14. Production planning of biopharmaceutical manufacture.

    OpenAIRE

    Lakhdar, K.

    2006-01-01

    Multiproduct manufacturing facilities running on a campaign basis are increasingly becoming the norm for biopharmaceuticals, owing to high risks of clinical failure, regulatory pressures and the increasing number of therapeutics in clinical evaluation. The need for such flexible plants and cost-effective manufacture pose significant challenges for planning and scheduling, which are compounded by long production lead times, intermediate product stability issues and the high cost - low volume n...

  15. Solar collector manufacturing activity, 1990

    International Nuclear Information System (INIS)

    1992-01-01

    The Solar Collector Manufacturing Activity 1990 report prepared by the Energy Information Administration (EIA) presents summary and detailed data provided by domestic manufacturers on shipments of solar thermal collectors and photovoltaic cells and modules. Summary data on solar thermal collector shipments are presented for the period 1974 through 1990. Summary data on photovoltaic cell and module shipments are presented for the period 1982 through 1990. Detailed information for solar thermal collectors and photovoltaic cells and modules are presented for 1990

  16. Manufacturing Innovation and Technological Superiority

    Science.gov (United States)

    2016-09-01

    Defense AT&L: September-October 2016 2 From the Under Secretary of Defense for Acquisit ion, Technology, and Logist ics Manufacturing Innovation...Farnborough International Airshow in England, where the Russians were offering to sell their most modern systems to anyone who would buy them. What...struck me most when I examined the former Soviet equipment was how primitive their production technology was compared to U.S. manufacturing technology

  17. CT-assisted agile manufacturing

    Science.gov (United States)

    Stanley, James H.; Yancey, Robert N.

    1996-11-01

    The next century will witness at least two great revolutions in the way goods are produced. First, workers will use the medium of virtual reality in all aspects of marketing, research, development, prototyping, manufacturing, sales and service. Second, market forces will drive manufacturing towards small-lot production and just-in-time delivery. Already, we can discern the merging of these megatrends into what some are calling agile manufacturing. Under this new paradigm, parts and processes will be designed and engineered within the mind of a computer, tooled and manufactured by the offspring of today's rapid prototyping equipment, and evaluated for performance and reliability by advanced nondestructive evaluation (NDE) techniques and sophisticated computational models. Computed tomography (CT) is the premier example of an NDE method suitable for future agile manufacturing activities. It is the only modality that provides convenient access to the full suite of engineering data that users will need to avail themselves of computer- aided design, computer-aided manufacturing, and computer- aided engineering capabilities, as well as newly emerging reverse engineering, rapid prototyping and solid freeform fabrication technologies. As such, CT is assured a central, utilitarian role in future industrial operations. An overview of this exciting future for industrial CT is presented.

  18. Comparative integrated manufacturing efficiency in production engineering

    OpenAIRE

    Koriath, Hans-Joachim; Kuznetsov, Alexandr; Kalyashina, A.V.

    2017-01-01

    At present a plurality of manufacturing methods, different manufacturing processes and manufacturing equipment are known in order to produce and customize work pieces and products. A new systematic approaches for the analysis and evaluation of manufacturing methods bases on the energy-information model as a conceptual approach to the comparative integrated manufacturing efficiency in production engineering. The integrated manufacturing efficiency is equal to the product of the efficiencies of...

  19. Exploring manufacturing competencies of a two wheeler manufacturing unit

    International Nuclear Information System (INIS)

    Singh, Chandan Deep; Khamba, Jaimal Singh; Singh, Rajdeep; Singh, Navdeep

    2014-01-01

    The two wheeler industry of India is one of the most dependable industries as every person has at least a two wheeler with him, if not any four wheeler. Earlier there were scooters like Bajaj Chetak, Priya but with evolution of motorcycles like splendor, splendor+, etc. the scooter market started declining but with arrival of gearless scooters like Honda Activa, Scooty Pep, etc. the market place has become increasingly competitive in recent time and industries are facing tough test of improving products and thus market share. The competitiveness among industries is an important issue. Competency development is a vital tool to enhance the competitiveness of industries. Based, on aggregate performance of a firm, it comprehensively explores the varying importance of manufacturing competencies and drives of industrial competitiveness. Hence by, exploring the manufacturing competencies of a two wheeler industry, one can reflect the competitiveness of two wheeler manufacturing industry as a whole. This study presents various factors of manufacturing competencies affecting industrial competitiveness as the significance of these competencies is increasing day by day in two wheeler manufacturing industry

  20. Knowledge Transfer and Manufacturing Relocation in International Manufacturing Networks

    DEFF Research Database (Denmark)

    Madsen, Erik Skov

    2014-01-01

    This paper is built on six longitudinal case studies of knowledge transfer in manufacturing relocation. By focusing on tacit and explicit knowledge the paper introduces a model for identification of knowledge in relation to four task situations on the shop floor in a manufacturing environment....... The paper discusses and suggests how the transfer of tacit and explicit knowledge can be improved. Further the paper discusses two dramatic shifts in organizational settings i.e. from operations management and to project management in the sending unit before a transfer and reverses in the receiving unit...

  1. Canadian Manufacturing Malaise: Three Hypotheses

    Directory of Open Access Journals (Sweden)

    Matt Krzepkowski

    2013-03-01

    Full Text Available The danger in politicians promoting the idea that “Dutch Disease” is responsible for the decline of the Ontario manufacturing sector is that the suggestion implies that Canada’s manufacturing sector will bounce back if only we could slow down oil sands development, or if the Canadian dollar were to devalue. In reality, evidence suggests that the decline in Ontario manufacturing is the result of long-term structural changes in the economy, independent of the rise of the country’s natural-resource sector and the rising dollar. And the sooner policymakers realize that, and stop blaming the decline in manufacturing on Dutch Disease (which holds that a booming natural-resource sector that drives up our dollar makes our manufacturing exports less competitive the sooner they can get to work on helping manufacturing-dependent regions transition to the evolving economy. A closer analysis of Canada’s manufacturing sector shows that jobs in that sector have been disappearing across the country since the end of the Second World War, with the sector’s share of employment falling dramatically well before rapid development began to take hold in the oil sands, and back when Canada’s dollar was still worth far less than the American dollar. It is a trend that has been occurring among most of our OECD peers, including the United States, which may be due to the widespread reallocation of production to lower cost countries. But it is also true that Canada’s manufacturing productivity performance in particular has been declining for a generation, with especially poor performance in the last decade, when labour productivity in Canada grew at just a quarter of the U.S. rate. Meanwhile, capital investment that may have improved the competitiveness of Canadian manufacturing has been anemic. Yet there is no particular reason to lament the scaling-down of manufacturing jobs in Ontario. The province remains just as economically important, as a share of

  2. Additive manufacturing in maxillofacial reconstruction

    Directory of Open Access Journals (Sweden)

    Dincă Luciana Laura

    2017-01-01

    Full Text Available In this paper the benefits of using additive manufacturing technologies in maxillofacial reconstruction are highlighted. Based on a real clinical case, the paper describes the manufacture of an implant prototype replacing the right zygomatic bone and a part of maxilla using additive manufacturing technologies. The face is the most expressive part of the human body that makes us unique. It was shown that the maxillofacial prostheses help to improve the psychological state of patients affected by, because low self esteem feeling appears commonly to this patients with the facial defects. The aim of this paper is to show how using additive manufacturing technologies methods within this research, the producing a surgical model will help surgeon to improve the pre-operative planning. For this we used additive manufacturing technologies such as Stereolitography to achieve the biomodel and FDM-fused deposition modelling to obtain a prototype model because these technologies make it possible to obtain prosthesis according to the physical and mechanical requirements of the region of implantation.

  3. The study of temperature and UV light effect in anthocyanin extract from dragon fruit (Hylocereus costaricensis) rind using UV-Visible spectrophotometer

    Science.gov (United States)

    Purbaningtias, Tri Esti; Aprilia, Anisa Cahyani; Fauzi'ah, Lina

    2017-12-01

    This study aimed to determine the total of anthocyanin content in ethanol extract from super red dragon fruit rind. The extraction was affected by temperature and light conditions. The determination of anthocyanin's total content was performed with a variation of pH and analyzed by UV-Visible spectrophotometer. The results showed that the average contained total anthocyanins obtained at room temperature, 40 and 60 °C were 4.6757, 5.6108, 21.9757 mg/L, respectively. In higher temperatures, it was observed the more anthocyanin extracted. The concentration of anthocyanin extract without UV light was 2.5716 mg/L, it was less than UV light assisted extract, i.e. 5.3770 mg / L.

  4. A new on-axis micro-spectrophotometer for combining Raman, fluorescence and UV/Vis absorption spectroscopy with macromolecular crystallography at the Swiss Light Source.

    Science.gov (United States)

    Pompidor, Guillaume; Dworkowski, Florian S N; Thominet, Vincent; Schulze-Briese, Clemens; Fuchs, Martin R

    2013-09-01

    The combination of X-ray diffraction experiments with optical methods such as Raman, UV/Vis absorption and fluorescence spectroscopy greatly enhances and complements the specificity of the obtained information. The upgraded version of the in situ on-axis micro-spectrophotometer, MS2, at the macromolecular crystallography beamline X10SA of the Swiss Light Source is presented. The instrument newly supports Raman and resonance Raman spectroscopy, in addition to the previously available UV/Vis absorption and fluorescence modes. With the recent upgrades of the spectral bandwidth, instrument stability, detection efficiency and control software, the application range of the instrument and its ease of operation were greatly improved. Its on-axis geometry with collinear X-ray and optical axes to ensure optimal control of the overlap of sample volumes probed by each technique is still unique amongst comparable facilities worldwide and the instrument has now been in general user operation for over two years.

  5. Aqueous photochemical reactions of chloride, bromide, and iodide ions in a diode-array spectrophotometer. Autoinhibition in the photolysis of iodide ions.

    Science.gov (United States)

    Kalmár, József; Dóka, Éva; Lente, Gábor; Fábián, István

    2014-03-28

    The aqueous photoreactions of three halide ions (chloride, bromide and iodide) were studied using a diode array spectrophotometer to drive and detect the process at the same time. The concentration and pH dependences of the halogen formation rates were studied in detail. The experimental data were interpreted by improving earlier models where the cage complex of a halogen atom and an electron has a central role. The triiodide ion was shown to exert a strong inhibiting effect on the reaction sequence leading to its own formation. An assumed chemical reaction between the triiodide ion and the cage complex interpreted the strong autoinhibition effect. It is shown that there is a real danger of unwanted interference from the photoreactions of halide ions when halide salts are used as supporting electrolytes in spectrophotometric experiments using a relatively high intensity UV light source.

  6. A spectrophotometer-based diffusivity assay reveals that diffusion hindrance of small molecules in extracellular matrix gels used in 3D cultures is dominated by viscous effects.

    Science.gov (United States)

    Galgoczy, Roland; Pastor, Isabel; Colom, Adai; Giménez, Alicia; Mas, Francesc; Alcaraz, Jordi

    2014-08-01

    The design of 3D culture studies remains challenging due to the limited understanding of extracellular matrix (ECM)-dependent hindered diffusion and the lack of simple diffusivity assays. To address these limitations, we set up a cost-effective diffusivity assay based on a Transwell plate and the spectrophotometer of a Microplate Reader, which are readily accessible to cell biology groups. The spectrophotometer-based assay was used to assess the apparent diffusivity D of FITC-dextrans with molecular weight (4-70kDa) spanning the physiological range of signaling factors in a panel of acellular ECM gels including Matrigel, fibrin and type I collagen. Despite their technical differences, D data exhibited ∼15% relative difference with respect to FRAP measurements. Our results revealed that diffusion hindrance of small particles is controlled by the enhanced viscosity of the ECM gel in conformance with the Stokes-Einstein equation rather than by geometrical factors. Moreover, we provided a strong rationale that the enhanced ECM viscosity is largely contributed to by unassembled ECM macromolecules. We also reported that gels with the lowest D exhibited diffusion hindrance closest to the large physiologic hindrance of brain tissue, which has a typical pore size much smaller than ECM gels. Conversely, sparse gels (≤1mg/ml), which are extensively used in 3D cultures, failed to reproduce the hindered diffusion of tissues, thereby supporting that dense (but not sparse) ECM gels are suitable tissue surrogates in terms of macromolecular transport. Finally, the consequences of reduced diffusivity in terms of optimizing the design of 3D culture experiments were addressed in detail. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Application of the correction's system of bottom by deuterium's lamp of a spectrophotometer of atomic absorption to the obtaining of ultraviolet spectrums

    International Nuclear Information System (INIS)

    Villalobos Chaves, Alberto Enrique

    2002-01-01

    The correction system of bottom by lamp of deuterium's arch of a spectrophotometer of atomic absorption has been utilized with sweep's capacity of wavelength to get spectrums of ultraviolet absorption of samples in gaseous phase, whether in presence as in absence of flame, in the region between 200 nm and 365 nm. The spectral information was obtained after of a process of electronic subtraction of the source's signal, except for the source's signal plus the sample and its subsequent analysis by a programmed data's processor to give a report in terms of wavelength. The spectrums obtained in absence of flame were practiced in samples contained in a gas's sell for infrared spectroscopy with polyethylene's windows, it is located of the burner and directly in front to the radiation's beam, comparable spectrums with the reported in the literature were obtained and with a bigger resolution than the measure with an conventional ultraviolet absorption's spectrophotometer utilized like reference. The spectrums in presence of flame have been of flame have been obtained from dissolved samples and directly suctioned, it achieves to obtain spectral information that is normally not detected conveniently when it performs qualitative analysis by emission of flame in elements such like zinc, lead, cobalt, mercury and nickel among other. The information obtained on this way has been utilized like an alternative method to the elemental analysis by humid way with a view to increase the reliability of the results that have been utilized like basis in the determination of the tariff classification of imported or exported products. (Author) [es

  8. Metrology for Fuel Cell Manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Stocker, Michael [National Inst. of Standards and Technology, Gaithersburg, MD (United States); Stanfield, Eric [National Inst. of Standards and Technology, Gaithersburg, MD (United States)

    2015-02-04

    The project was divided into three subprojects. The first subproject is Fuel Cell Manufacturing Variability and Its Impact on Performance. The objective was to determine if flow field channel dimensional variability has an impact on fuel cell performance. The second subproject is Non-contact Sensor Evaluation for Bipolar Plate Manufacturing Process Control and Smart Assembly of Fuel Cell Stacks. The objective was to enable cost reduction in the manufacture of fuel cell plates by providing a rapid non-contact measurement system for in-line process control. The third subproject is Optical Scatterfield Metrology for Online Catalyst Coating Inspection of PEM Soft Goods. The objective was to evaluate the suitability of Optical Scatterfield Microscopy as a viable measurement tool for in situ process control of catalyst coatings.

  9. Energy Efficiency in Manufacturing Systems

    CERN Document Server

    Thiede, Sebastian

    2012-01-01

    Energy consumption is of great interest to manufacturing companies. Beyond considering individual processes and machines, the perspective on process chains and factories as a whole holds major potentials for energy efficiency improvements. To exploit these potentials, dynamic interactions of different processes as well as auxiliary equipment (e.g. compressed air generation) need to be taken into account. In addition, planning and controlling manufacturing systems require  balancing technical, economic and environmental objectives. Therefore, an innovative and comprehensive methodology – with a generic energy flow-oriented manufacturing simulation environment as a core element – is developed and embedded into a step-by-step application cycle. The concept is applied in its entirety to a wide range of case studies such as aluminium die casting, weaving mills, and printed circuit board assembly in order to demonstrate the broad applicability and the benefits that can be achieved.

  10. The manufacturing blueprint environment : Bringing intelligence into manufacturing

    NARCIS (Netherlands)

    Papazoglou, Mike; Elgammal, Amal

    Manufacturers today are rapidly moving into a business climate that is characterized by the ability to fulfill orders on demand by doing business through short-term networks where they negotiate value-adding processes dynamically – taking into account quality, time, price, viability, sustainability,

  11. Exploring manufacturing solutions for SMEs

    DEFF Research Database (Denmark)

    Radziwon, Agnieszka; Blichfeldt, Henrik; Bilberg, Arne

    ’ automation processes. The paper presents an embedded case study based on 10 low- and medium-tech Danish companies. Based on the development of production paradigms and the presented study, this research helps to understand key determinants and processes for SMEs’ exploration of future directions......This exploratory study provides an overview over current state of manufacturing solutions in small and medium sized enterprises (SMEs) in region of Southern Denmark. Building on manufacturing paradigms, this paper reveals relevant aspects for the development and implementation of improving SMEs...

  12. Strategi Bersaing dengan Agile Manufacturing

    Directory of Open Access Journals (Sweden)

    Hamidah Tussifah

    2017-06-01

    Full Text Available Competitive advantage now increasingly rests upon a dynamic capability to compete successfully in an environment of frequent, challenging and unpredictable change. The agile manufacturing a recently popularized concept has been advocated as the 21st century manufacturing paradigm. In adopting and developing the key elements of agile manufactruring, there is requirement for enterprises to overcome the philosophical challenges of a shift from mass/lean production to the customization of agility. Beside that, enterprises should explore the key success factors to support succesfull agile implementation.

  13. Japan's technology and manufacturing infrastructure

    Science.gov (United States)

    Boulton, William R.; Meieran, Eugene S.; Tummala, Rao R.

    1995-01-01

    The JTEC panel found that, after four decades of development in electronics and manufacturing technologies, Japanese electronics companies are leaders in the development, support, and management of complex, low-cost packaging and assembly technologies used in the production of a broad range of consumer electronics products. The electronics industry's suppliers provide basic materials and equipment required for electronic packaging applications. Panelists concluded that some Japanese firms could be leading U.S. competitors by as much as a decade in these areas. Japan's technology and manufacturing infrastructure is an integral part of its microelectronics industry's success.

  14. Introduction to semiconductor manufacturing technology

    CERN Document Server

    2012-01-01

    IC chip manufacturing processes, such as photolithography, etch, CVD, PVD, CMP, ion implantation, RTP, inspection, and metrology, are complex methods that draw upon many disciplines. [i]Introduction to Semiconductor Manufacturing Technologies, Second Edition[/i] thoroughly describes the complicated processes with minimal mathematics, chemistry, and physics; it covers advanced concepts while keeping the contents accessible to readers without advanced degrees. Designed as a textbook for college students, this book provides a realistic picture of the semiconductor industry and an in-depth discuss

  15. Japan's technology and manufacturing infrastructure

    Science.gov (United States)

    Boulton, William R.; Meieran, Eugene S.; Tummala, Rao R.

    1995-02-01

    The JTEC panel found that, after four decades of development in electronics and manufacturing technologies, Japanese electronics companies are leaders in the development, support, and management of complex, low-cost packaging and assembly technologies used in the production of a broad range of consumer electronics products. The electronics industry's suppliers provide basic materials and equipment required for electronic packaging applications. Panelists concluded that some Japanese firms could be leading U.S. competitors by as much as a decade in these areas. Japan's technology and manufacturing infrastructure is an integral part of its microelectronics industry's success.

  16. Benchmarks of Global Clean Energy Manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Sandor, Debra [National Renewable Energy Lab. (NREL), Golden, CO (United States); Chung, Donald [National Renewable Energy Lab. (NREL), Golden, CO (United States); Keyser, David [National Renewable Energy Lab. (NREL), Golden, CO (United States); Mann, Margaret [National Renewable Energy Lab. (NREL), Golden, CO (United States); Engel-Cox, Jill [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2017-01-01

    The Clean Energy Manufacturing Analysis Center (CEMAC), sponsored by the U.S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy (EERE), provides objective analysis and up-to-date data on global supply chains and manufacturing of clean energy technologies. Benchmarks of Global Clean Energy Manufacturing sheds light on several fundamental questions about the global clean technology manufacturing enterprise: How does clean energy technology manufacturing impact national economies? What are the economic opportunities across the manufacturing supply chain? What are the global dynamics of clean energy technology manufacturing?

  17. A framework for distributed manufacturing applications

    OpenAIRE

    Leitão, Paulo; Restivo, Francisco

    2000-01-01

    The new organisational structures used in world wide manufacturing systems require the development of distributed applications, which present solutions to their requirements. The work research in the distributed manufacturing control leads to emergent paradigms, such as Holonic Manufacturing Systems (HMS) and Bionic Manufacturing Systems (BMS), which translates the concepts from social organisations and biological systems to the manufacturing world. This paper present a Framework for the deve...

  18. Pellet to Part Manufacturing System for CNCs

    Energy Technology Data Exchange (ETDEWEB)

    Roschli, Alex C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Love, Lonnie J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Post, Brian K. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Chesser, Phillip C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Lloyd, Peter D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Bandari, Yashwanth Kumar [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Jones, Jason [Hybrid Manufacturing Technologies, Swadlincote (United Kingdom); Gaul, Katherine T. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2018-03-14

    Oak Ridge National Laboratory’s Manufacturing Demonstration Facility worked with Hybrid Manufacturing Technologies to develop a compact prototype composite additive manufacturing head that can effectively extrude injection molding pellets. The head interfaces with conventional CNC machine tools enabling rapid conversion of conventional machine tools to additive manufacturing tools. The intent was to enable wider adoption of Big Area Additive Manufacturing (BAAM) technology and combine BAAM technology with conventional machining systems.

  19. Directory of Manufacturing Research Centers

    Science.gov (United States)

    1989-06-01

    Grimm, Bob 175 Dryden, Robert 113 Groover , Mikell P. 124 Dubow, Joel 48 Gros, Percy J. 83 Dubowski, Steven 106 Gruver, William A. 60 Duffie, Neil A. 167...Mikell P. Groover , Director Technical areas include manufacturing processes, emphasis on machining, standalone automation, material handling and

  20. Capillary Sharp Inner Edge Manufacturing

    Czech Academy of Sciences Publication Activity Database

    Hošek, Jan; Studenovský, K.; Najdek, D.

    2009-01-01

    Roč. 19, č. 35 (2009), s. 19-25 ISSN 1584-5982. [MECAHITECH 09 /1./. Bukurešť, 08.10.2009-09.10.2009] R&D Projects: GA AV ČR IAA200760905 Institutional research plan: CEZ:AV0Z20760514 Keywords : capillary * edge * manufacturing Subject RIV: JR - Other Machinery

  1. CNC Preparation Meets Manufacturing Opportunity

    Science.gov (United States)

    Cassola, Joel

    2006-01-01

    This article features the machining technology program at Cape Fear Community College (CFCC) of Wilmington, North Carolina. North Carolina's Cape Fear Community College is working to meet diverse industry needs through its CNC training. The school's program has gained the attention of the local manufacturing community and students when it shifted…

  2. Flexible automated manufacturing for SMEs

    DEFF Research Database (Denmark)

    Grube Hansen, David; Bilberg, Arne; Madsen, Erik Skov

    SMEs are in general highly flexible and agile in order to accommodate the customer demands in the paradigm of High Mix-Low Volume manufacturing. The flexibility and agility have mainly been enabled by manual labor, but as we are entering the technology and data driven fourth industrial revolution...

  3. Modeling control in manufacturing simulation

    NARCIS (Netherlands)

    Zee, Durk-Jouke van der; Chick, S.; Sánchez, P.J.; Ferrin, D.; Morrice, D.J.

    2003-01-01

    A significant shortcoming of traditional simulation languages is the lack of attention paid to the modeling of control structures, i.e., the humans or systems responsible for manufacturing planning and control, their activities and the mutual tuning of their activities. Mostly they are hard coded

  4. Analysis of cellular manufacturing systems

    NARCIS (Netherlands)

    Heragu, Sunderesh; Zijm, Willem H.M.; Meng, Gang; Heragu, S.S.; van Ommeren, Jan C.W.; van Houtum, Geert-Jan

    2001-01-01

    In this paper, we present an open queuing network modeling approach to estimate performance measures of a cellular manufacturing layout. It is assumed a layout and production data for a planning period of specified length are available. The production data takes into account, processing and handling

  5. Additively manufactured porous tantalum implants

    NARCIS (Netherlands)

    Wauthle, Ruben; Van Der Stok, Johan; Yavari, Saber Amin; Van Humbeeck, Jan; Kruth, Jean Pierre; Zadpoor, Amir Abbas; Weinans, Harrie; Mulier, Michiel; Schrooten, Jan

    2015-01-01

    The medical device industry's interest in open porous, metallic biomaterials has increased in response to additive manufacturing techniques enabling the production of complex shapes that cannot be produced with conventional techniques. Tantalum is an important metal for medical devices because of

  6. Sustainability Characterization for Additive Manufacturing.

    Science.gov (United States)

    Mani, Mahesh; Lyons, Kevin W; Gupta, S K

    2014-01-01

    Additive manufacturing (AM) has the potential to create geometrically complex parts that require a high degree of customization, using less material and producing less waste. Recent studies have shown that AM can be an economically viable option for use by the industry, yet there are some inherent challenges associated with AM for wider acceptance. The lack of standards in AM impedes its use for parts production since industries primarily depend on established standards in processes and material selection to ensure the consistency and quality. Inability to compare AM performance against traditional manufacturing methods can be a barrier for implementing AM processes. AM process sustainability has become a driver due to growing environmental concerns for manufacturing. This has reinforced the importance to understand and characterize AM processes for sustainability. Process characterization for sustainability will help close the gaps for comparing AM performance to traditional manufacturing methods. Based on a literature review, this paper first examines the potential environmental impacts of AM. A methodology for sustainability characterization of AM is then proposed to serve as a resource for the community to benchmark AM processes for sustainability. Next, research perspectives are discussed along with relevant standardization efforts.

  7. Improved Methods for Production Manufacturing Processes in Environmentally Benign Manufacturing

    Directory of Open Access Journals (Sweden)

    Yan-Yan Wang

    2011-09-01

    Full Text Available How to design a production process with low carbon emissions and low environmental impact as well as high manufacturing performance is a key factor in the success of low-carbon production. It is important to address concerns about climate change for the large carbon emission source manufacturing industries because of their high energy consumption and environmental impact during the manufacturing stage of the production life cycle. In this paper, methodology for determining a production process is developed. This methodology integrates process determination from three different levels: new production processing, selected production processing and batch production processing. This approach is taken within a manufacturing enterprise based on prior research. The methodology is aimed at providing decision support for implementing Environmentally Benign Manufacturing (EBM and low-carbon production to improve the environmental performance of the manufacturing industry. At the first level, a decision-making model for new production processes based on the Genetic Simulated Annealing Algorithm (GSAA is presented. The decision-making model considers not only the traditional factors, such as time, quality and cost, but also energy and resource consumption and environmental impact, which are different from the traditional methods. At the second level, a methodology is developed based on an IPO (Input-Process-Output model that integrates assessments of resource consumption and environmental impact in terms of a materials balance principle for batch production processes. At the third level, based on the above two levels, a method for determining production processes that focus on low-carbon production is developed based on case-based reasoning, expert systems and feature technology for designing the process flow of a new component. Through the above three levels, a method for determining the production process to identify, quantify, assess, and optimize the

  8. Lean manufacturing in Indian context: A survey

    Directory of Open Access Journals (Sweden)

    Rakesh Kumar

    2015-04-01

    Full Text Available This paper is an attempt to examine the implementation of Lean Manufacturing system in the Indian industries. Predominant elements of Lean Manufacturing, benefits gained after its implementation and obstacles observed by Indian Industry have been recognized. The results of this survey support the opinion that Lean Manufacturing had potential to improve the organizational performance of Indian industries. Nevertheless, Indian industries are required to be passionate to transform their manufacturing by adopting Lean manufacturing to gain the full benefits. A large numbers of literature papers are available on the better side of Lean manufacturing approach and its benefits gained by manufacturing organizations after implementation. But the adverse impacts of Lean manufacturing are not discussed to a great extent. Some drawbacks of Lean manufacturing are also highlighted in this paper.

  9. Advance Manufacturing Office FY 2017 Budget At-A-Glance

    Energy Technology Data Exchange (ETDEWEB)

    None

    2016-03-01

    The Advanced Manufacturing Office (AMO) brings together manufacturers, research institutions, suppliers, and universities to investigate manufacturing processes, information, and materials technologies critical to advance domestic manufacturing of clean energy products, and to support energy productivity across the entire manufacturing sector.

  10. Manufacturing

    Directory of Open Access Journals (Sweden)

    Kovalenko Iaroslav

    2017-04-01

    Full Text Available This article describes a method of in-situ process monitoring in the digital light processing (DLP 3D printer. It is based on the continuous measurement of the adhesion force between printing surface and bottom of a liquid resin bath. This method is suitable only for the bottom-up DPL printers. Control system compares the force at the moment of unsticking of printed layer from the bottom of the tank, when it has the largest value in printing cycle, with theoretical value. Implementation of suggested algorithm can make detection of faults during the printing process possible.

  11. Agreement between digital image analysis and clinical spectrophotometer in CIEL*C*h° coordinate differences and total color difference (ΔE) measurements of dental ceramic shade tabs.

    Science.gov (United States)

    Farah, Ra'fat I

    2016-01-01

    The objectives of this in vitro study were: 1) to test the agreement among color coordinate differences and total color difference (ΔL*, ΔC*, Δh°, and ΔE) measurements obtained by digital image analysis (DIA) and spectrophotometer, and 2) to test the reliability of each method for obtaining color differences. A digital camera was used to record standardized images of each of the 15 shade tabs from the IPS e.max shade guide placed edge-to-edge in a phantom head with a reference shade tab. The images were analyzed using image-editing software (Adobe Photoshop) to obtain the color differences between the middle area of each test shade tab and the corresponding area of the reference tab. The color differences for the same shade tab areas were also measured using a spectrophotometer. To assess the reliability, measurements for the 15 shade tabs were repeated twice using the two methods. The Intraclass Correlation Coefficient (ICC) and the Dahlberg index were used to calculate agreement and reliability. The total agreement of the two methods for measuring ΔL*, ΔC*, Δh°, and ΔE, according to the ICC, exceeded 0.82. The Dahlberg indices for ΔL* and ΔE were 2.18 and 2.98, respectively. For the reliability calculation, the ICCs for the DIA and the spectrophotometer ΔE were 0.91 and 0.94, respectively. High agreement was obtained between the DIA and spectrophotometer results for the ΔL*, ΔC*, Δh°, and ΔE measurements. Further, the reliability of the measurements for the spectrophotometer was slightly higher than the reliability of all measurements in the DIA.

  12. Neutron Characterization for Additive Manufacturing

    Science.gov (United States)

    Watkins, Thomas; Bilheux, Hassina; An, Ke; Payzant, Andrew; DeHoff, Ryan; Duty, Chad; Peter, William; Blue, Craig; Brice, Craig A.

    2013-01-01

    Oak Ridge National Laboratory (ORNL) is leveraging decades of experience in neutron characterization of advanced materials together with resources such as the Spallation Neutron Source (SNS) and the High Flux Isotope Reactor (HFIR) shown in Fig. 1 to solve challenging problems in additive manufacturing (AM). Additive manufacturing, or three-dimensional (3-D) printing, is a rapidly maturing technology wherein components are built by selectively adding feedstock material at locations specified by a computer model. The majority of these technologies use thermally driven phase change mechanisms to convert the feedstock into functioning material. As the molten material cools and solidifies, the component is subjected to significant thermal gradients, generating significant internal stresses throughout the part (Fig. 2). As layers are added, inherent residual stresses cause warping and distortions that lead to geometrical differences between the final part and the original computer generated design. This effect also limits geometries that can be fabricated using AM, such as thin-walled, high-aspect- ratio, and overhanging structures. Distortion may be minimized by intelligent toolpath planning or strategic placement of support structures, but these approaches are not well understood and often "Edisonian" in nature. Residual stresses can also impact component performance during operation. For example, in a thermally cycled environment such as a high-pressure turbine engine, residual stresses can cause components to distort unpredictably. Different thermal treatments on as-fabricated AM components have been used to minimize residual stress, but components still retain a nonhomogeneous stress state and/or demonstrate a relaxation-derived geometric distortion. Industry, federal laboratory, and university collaboration is needed to address these challenges and enable the U.S. to compete in the global market. Work is currently being conducted on AM technologies at the ORNL

  13. Mechanical Prototyping and Manufacturing Internship

    Science.gov (United States)

    Grenfell, Peter

    2016-01-01

    The internship was located at the Johnson Space Center (JSC) Innovation Design Center (IDC), which is a facility where the JSC workforce can meet and conduct hands-on innovative design, fabrication, evaluation, and testing of ideas and concepts relevant to NASA's mission. The tasks of the internship included mechanical prototyping design and manufacturing projects in service of research and development as well as assisting the users of the IDC in completing their manufacturing projects. The first project was to manufacture hatch mechanisms for a team in the Systems Engineering and Project Advancement Program (SETMAP) hexacopter competition. These mechanisms were intended to improve the performance of the servomotors and offer an access point that would also seal to prevent cross-contamination. I also assisted other teams as they were constructing and modifying their hexacopters. The success of this competition demonstrated a proof of concept for aerial reconnaissance and sample return to be potentially used in future NASA missions. I also worked with Dr. Kumar Krishen to prototype an improved thermos and a novel, portable solar array. Computer-aided design (CAD) software was used to model the parts for both of these projects. Then, 3D printing as well as conventional techniques were used to produce the parts. These prototypes were then subjected to trials to determine the success of the designs. The solar array is intended to work in a cluster that is easy to set up and take down and doesn't require powered servomechanisms. It could be used terrestrially in areas not serviced by power grids. Both projects improve planetary exploration capabilities to future astronauts. Other projects included manufacturing custom rail brackets for EG-2, assisting engineers working on underwater instrument and tool cases for the NEEMO project, and helping to create mock-up parts for Space Center Houston. The use of the IDC enabled efficient completion of these projects at

  14. Modular mechatronic control of reconfigurable manufacturing system for mass customization manufacturing

    CSIR Research Space (South Africa)

    Xing, B

    2007-01-01

    Full Text Available Manufacturing companies are faced with the challenge of unpredictable, high frequency market changes in both local and international markets. There is a need for greater, more effective responsiveness by manufacturers to change their manufacturing...

  15. The Frontiers of Additive Manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Grote, Christopher John [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-03-03

    Additive manufacturing, more commonly known as 3-D printing, has become a ubiquitous tool in science for its precise control over mechanical design. For additive manufacturing to work, a 3-D structure is split into thin 2D slices, and then different physical properties, such as photo-polymerization or melting, are used to grow the sequential layers. The level of control allows not only for devices to be made with a variety of materials: e.g. plastics, metals, and quantum dots, but to also have finely controlled structures leading to other novel properties. While 3-D printing is widely used by hobbyists for making models, it also has industrial applications in structural engineering, biological tissue scaffolding, customized electric circuitry, fuel cells, security, and more.

  16. Manufacturing Outsourcing A Knowledge Perspective

    CERN Document Server

    Rolstadås, Asbjørn; O'Sullivan, David

    2012-01-01

    All companies which reach a critical size are faced with outsourcing decisions that can increase the value of their products and services primarily through lower costs, greater reliability and improved efficiency. Successful outsourcing decisions have an important knowledge dimension, where the outsourcing professionals need to be supported by historical and contextual knowledge regarding their own products performance but also the performance of suppliers. Outsourcing in Manufacturing: the Knowledge Dimension explains in detail how a manager can acquire, create, transfer and use knowledge that optimizes their outsourcing decisions and improves the changes of marketplace success.              Outsourcing in Manufacturing: the Knowledge Dimension gives examples of the key decisions that needs to be taken by managers regarding effective outsourcing. Decisions are divided around the structural and infrastructural aspects of outsourcing and the key knowledge that needs to be managed to support good de...

  17. Safety in a Manufacturing Company

    Directory of Open Access Journals (Sweden)

    Kopczewski Marian

    2017-02-01

    Full Text Available The safety systems include the functioning of the institutions of a state, central, and local government, businesses, and social organizations. Research in this discipline should contribute to the development of the theoretical foundations and systems of national and international security and operating systems in the area of technical safety. Technical safety engineering should deal with a design, build, operation, and decommissioning of technical measures in order to minimize the opportunities and the size of their negative impact on the environment, people, and the good of civilization. With this in mind, the main purpose of the research was to evaluate the safety of technical manufacturing company that uses a wide machine park. A plant manufacturing parts and components for automobiles was the audited company.

  18. Method of manufacturing fuel cores

    International Nuclear Information System (INIS)

    Oizumi, C.H.; Uesugi, J.N.

    1977-01-01

    The manufacture of fuel cores for coated nuclear fuels which are to be used in gas-cooled high temperature reactors is described. By addition of β-1.4-glucane to Th, U, or Pu cmpounds there is obtained a mixture, in the presence of a dispersion medium, is granulated to small spheres which are dried, heated and later provided with a coating. 16 examples illustrate details of the method. (UWI) [de

  19. Resource efficiency in car manufacturing

    OpenAIRE

    Neugebauer, Reimund; Hellfritzsch, Udo; Lahl, Mike; Milbrandt, Matthias; Schiller, Sven; Druwe, Thomas

    2011-01-01

    The Automotive Component Manufacturers Association of India (ACMA) is the nodal agency for the Indian Auto Component Industry. It's active involvement in trade promotion, technology up-gradation, quality enhancement and collection and dissemination of information has made it a vital catalyst for this industry's development. It's other activities include participation in international trade fairs, sending trade delegations overseas and bringing out publications on various subjects related to t...

  20. Reactive polymer fused deposition manufacturing

    Science.gov (United States)

    Kunc, Vlastimil; Rios, Orlando; Love, Lonnie J.; Duty, Chad E.; Johs, Alexander

    2017-05-16

    Methods and compositions for additive manufacturing that include reactive or thermosetting polymers, such as urethanes and epoxies. The polymers are melted, partially cross-linked prior to the depositing, deposited to form a component object, solidified, and fully cross-linked. These polymers form networks of chemical bonds that span the deposited layers. Application of a directional electromagnetic field can be applied to aromatic polymers after deposition to align the polymers for improved bonding between the deposited layers.

  1. Manufacturing of Plutonium Tensile Specimens

    Energy Technology Data Exchange (ETDEWEB)

    Knapp, Cameron M [Los Alamos National Laboratory

    2012-08-01

    Details workflow conducted to manufacture high density alpha Plutonium tensile specimens to support Los Alamos National Laboratory's science campaigns. Introduces topics including the metallurgical challenge of Plutonium and the use of high performance super-computing to drive design. Addresses the utilization of Abaqus finite element analysis, programmable computer numerical controlled (CNC) machining, as well as glove box ergonomics and safety in order to design a process that will yield high quality Plutonium tensile specimens.

  2. Imaging Grating SpectroPhotometer (I-GRASP) for Solar Soft X-Ray Spectra and Images from a Cube Sat Mission

    Science.gov (United States)

    Didkovsky, Leonid V.; Wieman, Seth; Woods, Thomas N.; Jones, Andrew; Chao, Weilun

    2016-05-01

    We describe the Soft X-ray Imaging Grating SpectroPhotometer (I-GRASP), a novel spectrophotometer with four times narrower transmission grating period (about 50 nm) compared to the MIT-designed 200 nm gratings successfully used for the SOHO/SEM, the SDO/EVE/ESP, and the Solar Aspect Monitor (SAM) onboard the EVE sounding rocket suite of instruments. The new grating is based on technology developed at the Lawrence Berkeley National Laboratory (LBNL) and provides four to five time greater diffraction dispersion than the 200 nm period gratings. Such new technology will provide detection of both 0.1 nm - resolved solar spectra in about 1.0 to 7.0 nm spectral range and a soft X-ray pin-hole solar image from the I-GRASP instrument that is appropriately sized for a CubeSat platform. The solar observations of this soft X-ray range do not currently have spectral resolution, so I-GRASP concurrent spectral and imaging X-ray observations will be important for:Improvements in modeling of coronal dynamics and heating by comparing measured and modeled spectra through identifying changes in abundances from different active regions- Resolving some differences in certain iron spectral line intensity ratios observed with SAM, identifying key emission lines, and comparing to those modeled with the CHIANTI atomic database- Studying SXR spectral variability for different solar activity periods including solar flares and the 27-day solar rotation- Studying of the Earth’s ionosphere, thermosphere and mesosphere responses using as input the detailed soft X-ray spectra from I-GRASP- Improving solar soft X-ray reference spectra for accurate calculations of absolute solar irradiance from the SDO/EVE/ESP, SDO/EVE/SAM, TIMED/SEE/XPS, and SORCE/XPS channels that have broadband measurements of the 1-7 nm band- Providing validation for the soft X-Ray observations from the MinXSS CubeSat X123 spectrometer (0.04 to 2.5 nm) with the I-GRASP spectral observations from 1.0 to 7.0 nm- Comparing I

  3. Additive manufacturing of tunable lenses

    Science.gov (United States)

    Schlichting, Katja; Novak, Tobias; Heinrich, Andreas

    2017-02-01

    Individual additive manufacturing of optical systems based on 3D Printing offers varied possibilities in design and usage. In addition to the additive manufacturing procedure, the usage of tunable lenses allows further advantages for intelligent optical systems. Our goal is to bring the advantages of additive manufacturing together with the huge potential of tunable lenses. We produced tunable lenses as a bundle without any further processing steps, like polishing. The lenses were designed and directly printed with a 3D Printer as a package. The design contains the membrane as an optical part as well as the mechanical parts of the lens, like the attachments for the sleeves which contain the oil. The dynamic optical lenses were filled with an oil. The focal length of the lenses changes due to a change of the radius of curvature. This change is caused by changing the pressure in the inside of the lens. In addition to that, we designed lenses with special structures to obtain different areas with an individual optical power. We want to discuss the huge potential of this technology for several applications. Further, an appropriate controlling system is needed. Wéll show the possibilities to control and regulate the optical power of the lenses. The lenses could be used for illumination tasks, and in the future, for individual measurement tasks. The main advantage is the individuality and the possibility to create an individual design which completely fulfills the requirements for any specific application.

  4. Nuclear fuel manufacture and technology

    International Nuclear Information System (INIS)

    Nuclear power accounts for approximately 17% of the world's total electrical energy production. Over 30 countries operate in excess of 430 nuclear power plants with a combined generating capacity of more than 340 000 MWe. BNFL is a leading force in the international nuclear industry, supplying products and services across the complete fuel cycle business spectrum. These services and products include fuel and intermediate products manufacture, reprocessing, transport, waste management and decommissioning. This paper describes the processes involved in taking uranium ore as a raw material through to the production of advanced fuels and focuses on the manufacture and technology for both uranium oxide (UO 2 ) and mixed oxide (MOX) fuels. As a light water reactor (LWR) fuel fabricator, BNFL is able to manufacture MOX or UO 2 fuel utilizing recycled uranium. This paper discusses the technology involved in the use of plutonium or uranium oxide recovered from reprocessing and other advanced fuel technical issues. Improved production methods and the application of advanced engineering permits the next generation of fuel fabrication plants to capitalize on advances in technology. The long-term research and development (R and D) commitments by BNFL are outlined in this paper, indicating the levels of investment needed in R and D to accommodate a high technology company in an international market. (author)

  5. Flavoring exposure in food manufacturing.

    Science.gov (United States)

    Curwin, Brian D; Deddens, Jim A; McKernan, Lauralynn T

    2015-05-01

    Flavorings are substances that alter or enhance the taste of food. Workers in the food-manufacturing industry, where flavorings are added to many products, may be exposed to any number of flavoring compounds. Although thousands of flavoring substances are in use, little is known about most of these in terms of worker health effects, and few have occupational exposure guidelines. Exposure assessment surveys were conducted at nine food production facilities and one flavor manufacturer where a total of 105 area and 74 personal samples were collected for 13 flavoring compounds including five ketones, five aldehydes, and three acids. The majority of the samples were below the limit of detection (LOD) for most compounds. Diacetyl had eight area and four personal samples above the LOD, whereas 2,3-pentanedione had three area samples above the LOD. The detectable values ranged from 25-3124 ppb and 15-172 ppb for diacetyl and 2,3-pentanedione respectively. These values exceed the proposed National Institute for Occupational Safety and Health (NIOSH) recommended exposure limit for these compounds. The aldehydes had the most detectable samples, with each of them having >50% of the samples above the LOD. Acetaldehyde had all but two samples above the LOD, however, these samples were below the OSHA PEL. It appears that in the food-manufacturing facilities surveyed here, exposure to the ketones occurs infrequently, however levels above the proposed NIOSH REL were found. Conversely, aldehyde exposure appears to be ubiquitous.

  6. FRIDA integral field unit manufacturing

    Science.gov (United States)

    Cuevas, Salvador; Eikenberry, Stephen S.; Sánchez, Beatriz

    2014-07-01

    FRIDA (inFRared Imager and Dissector for the Adaptive optics system of the Gran Telescopio Canarias) has been designed as a cryogenic and diffraction limited instrument that will offer broad and narrow band imaging and integral field spectroscopy (IFS). Both, the imaging mode and IFS observing modes will use the same Teledyne 2Kx2K detector. This instrument will be installed at Nasmyth B station, behind the GTC Adaptive Optics system (GTCAO). FRIDA will provide the IFS mode using a 30 slices Integral Field Unit (IFU). This IFU design is based on the University of Florida FISICA where the mirror block arrays are diamond turned on monolithic metal blocks. The FRIDA IFU is of the slicer type; conformed mainly by 3 mirror blocks with 30 spherical mirrors each. It also has a Schwarzschild relay based on two off axis spherical mirrors and an afocal system of two parabolic off axis mirrors. Including two insertion mirrors the IFU holds 96 metal mirrors. All the mirrors have been manufactured by diamond turning techniques on monolithic blocks of aluminum 6061-T6 coated by a Nickel alloy. Except for the Schwarzschild relay and the insertion mirrors, 92 mirrors were manufactured by Corning in Keene NH, USA. The different blocks and mirrors are mounted on an opto-mechanical support that ensures the image quality and integrity of the complete IFU. In this work advances on the manufacturing of the FRIDA IFU components are described. Furthermore, the mirror blocks individual verification tests and are also described.

  7. Additive Manufacturing of Fuel Injectors

    Energy Technology Data Exchange (ETDEWEB)

    Sadek Tadros, Dr. Alber Alphonse [Edison Welding Institute, Inc., Columbus, OH (United States); Ritter, Dr. George W. [Edison Welding Institute, Inc., Columbus, OH (United States); Drews, Charles Donald [Edison Welding Institute, Inc., Columbus, OH (United States); Ryan, Daniel [Solar Turbines Inc., San Diego, CA (United States)

    2017-10-24

    Additive manufacturing (AM), also known as 3D-printing, has been shifting from a novelty prototyping paradigm to a legitimate manufacturing tool capable of creating components for highly complex engineered products. An emerging AM technology for producing metal parts is the laser powder bed fusion (L-PBF) process; however, industry manufacturing specifications and component design practices for L-PBF have not yet been established. Solar Turbines Incorporated (Solar), an industrial gas turbine manufacturer, has been evaluating AM technology for development and production applications with the desire to enable accelerated product development cycle times, overall turbine efficiency improvements, and supply chain flexibility relative to conventional manufacturing processes (casting, brazing, welding). Accordingly, Solar teamed with EWI on a joint two-and-a-half-year project with the goal of developing a production L-PBF AM process capable of consistently producing high-nickel alloy material suitable for high temperature gas turbine engine fuel injector components. The project plan tasks were designed to understand the interaction of the process variables and their combined impact on the resultant AM material quality. The composition of the high-nickel alloy powders selected for this program met the conventional cast Hastelloy X compositional limits and were commercially available in different particle size distributions (PSD) from two suppliers. Solar produced all the test articles and both EWI and Solar shared responsibility for analyzing them. The effects of powder metal input stock, laser parameters, heat treatments, and post-finishing methods were evaluated. This process knowledge was then used to generate tensile, fatigue, and creep material properties data curves suitable for component design activities. The key process controls for ensuring consistent material properties were documented in AM powder and process specifications. The basic components of the project

  8. Improved Large Aperture Collector Manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    O' Rourke, Deven [Abengoa Solar LLC, Lakewood, CO (United States); Farr, Adrian [Abengoa Solar LLC, Lakewood, CO (United States)

    2015-12-01

    The parabolic trough is the most established CSP technology and carries a long history of design experimentation dating back to the 1970’s. This has led to relatively standardized collector architectures, a maturing global supply chain, and a fairly uniform cost reduction strategy. Abengoa has deployed more than 1,500MWe of CSP troughs across several countries and has built and tested full-scale prototypes of many R&D concepts. The latest trough R&D efforts involved efforts to internalize non-CSP industry experience including a preliminary DFMA principles review done with Boothroyd Dewhurst, a construction literature review by the Arizona State University School of Construction Management, and two more focused manufacturing engineering subcontracts done by Ricardo Inc. and the nonprofit Edison Welding Institute. The first two studies highlighted strong opportunities in lowering part count, standardizing components and fasteners, developing modular designs to support prefabrication and automation, and devising simple, error-proof manual assembly methods. These principles have delivered major new cost savings in otherwise “mature” products in analogous industries like automotive, truck trailer manufacture, metal building fabrication, and shipbuilding. For this reason, they were core in the design development of the SpaceTube® collector, and arguably key to its early successes. The latter two studies were applied specifically to the first-generation SpaceTube® design and were important in setting the direction of the present SolarMat project. These studies developed a methodology to analyze the costs of manufacture and assembly, and identify new tooling concepts for more efficient manufacture. Among the main opportunities identified in these studies were the automated mirror arm manufacturing concept and the need for a less infrastructure-intensive assembly line, both of which now form central pillars of the SolarMat project strategy. These new designs will be

  9. Additive Manufacturing of Ion Thruster Optics Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Plasma Controls will manufacture and test a set of ion optics for electric propulsion ion thrusters using additive manufacturing technology, also known as 3D...

  10. A Database Approach to Computer Integrated Manufacturing

    Science.gov (United States)

    1988-06-01

    BACKGROUND .......................................................................................... 28 B. WHAT IS COMPUTER INTEGRATED MANUFACTURING...CIM is a modular approach to integration. B. WHAT IS COMPUTER INTEGRATED MANUFACTURING? There is a wide diversity of definitions of CIM in the

  11. Statistical and Computational Techniques in Manufacturing

    CERN Document Server

    2012-01-01

    In recent years, interest in developing statistical and computational techniques for applied manufacturing engineering has been increased. Today, due to the great complexity of manufacturing engineering and the high number of parameters used, conventional approaches are no longer sufficient. Therefore, in manufacturing, statistical and computational techniques have achieved several applications, namely, modelling and simulation manufacturing processes, optimization manufacturing parameters, monitoring and control, computer-aided process planning, etc. The present book aims to provide recent information on statistical and computational techniques applied in manufacturing engineering. The content is suitable for final undergraduate engineering courses or as a subject on manufacturing at the postgraduate level. This book serves as a useful reference for academics, statistical and computational science researchers, mechanical, manufacturing and industrial engineers, and professionals in industries related to manu...

  12. Acquisition of equipment for composite manufacturing laboratory.

    Science.gov (United States)

    2009-12-01

    An interdisciplinary team of faculty was formed to upgrade the Composite Manufacturing and Testing Facilities at Missouri S&T. The Metering Unit is useful to manufacture composite pultruded parts using two part polyurethane resin system. Prior to the...

  13. 7 CFR 1170.5 - Manufacturer.

    Science.gov (United States)

    2010-01-01

    ... Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements and Orders; Milk), DEPARTMENT OF AGRICULTURE DAIRY PRODUCT MANDATORY REPORTING § 1170.5 Manufacturer... manufacturing dairy products in one or more locations. ...

  14. Zambian manufacturing performance in comparative perspective

    NARCIS (Netherlands)

    Szirmai, Adam; Yamfwa, Francis; Lwamba, Chibwe

    2002-01-01

    This paper presents an analysis of Zambian manufacturing performance since 1964. It presents new estimates of labour productivity growth and total factor productivity growth. After a period of growth and labour productivity improvement till 1974, Zambian manufacturing suffered from increasing

  15. Nanosensor Fabrication with 3D Manufacturing Techniques

    Data.gov (United States)

    National Aeronautics and Space Administration — We use 3D manufacturing techniques to fabricate sensors based on nanomaterials. We use 3D manufacturing techniques to fabricate sensors based on nanomaterials. This...

  16. THE DYNAMICS OF BEST MANUFACTURING PRACTICES

    DEFF Research Database (Denmark)

    Timenes Laugen, Bjørge; Acur, Nuran; Boer, Harry

    and manufacturing, and improving manufacturing process maintain their status as best practices, while servitization and supply chain management are new best practices. Globalization and responsibility are proposed as promising practices, and technology is suggested as a qualifying practice....

  17. Plastics and Rubber Products Manufacturing (NAICS 326)

    Science.gov (United States)

    Find environmental regulatory and compliance information for plastics and rubber products manufacturing (which includes the manufacture of cellulose and other fibers) including information about NESHAPs and effluent guidelines for wastewater discharges

  18. Hydropower Manufacturing and Supply Chain Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Cotrell, Jason R [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-01-02

    Hydropower Manufacturing and Supply Chain Analysis presentation from the WPTO FY14-FY16 Peer Review. The project objective is to provide data and insights to inform investment strategies, policy, and other decisions to promote economic growth and manufacturing.

  19. SMP Bladder Tooling for Manufacturing Composites Project

    Data.gov (United States)

    National Aeronautics and Space Administration — CRG's shape memory polymer (SMP) Bladder Tooling is a cutting-edge manufacturing technology that can meet the manufacturing needs of the Ares launch vehicles. This...

  20. Additive Manufacturing of Aerospace Propulsion Components

    Science.gov (United States)

    Misra, Ajay K.; Grady, Joseph E.; Carter, Robert

    2015-01-01

    The presentation will provide an overview of ongoing activities on additive manufacturing of aerospace propulsion components, which included rocket propulsion and gas turbine engines. Future opportunities on additive manufacturing of hybrid electric propulsion components will be discussed.

  1. Current trend in latex dipped products manufacturing

    International Nuclear Information System (INIS)

    Wong, W.S.C.

    1996-01-01

    The paper present the activities in dipped products manufacturing in Malaysia; the activities carried out by MARGMA - Malaysian Rubber Glove manufacturer; other issues discussed such as labour, pricing environmental issue, product certification in this activity

  2. Design and additive manufacture for flow chemistry.

    Science.gov (United States)

    Capel, Andrew J; Edmondson, Steve; Christie, Steven D R; Goodridge, Ruth D; Bibb, Richard J; Thurstans, Matthew

    2013-12-07

    We review the use of additive manufacturing (AM) as a novel manufacturing technique for the production of milli-scale reactor systems. Five well-developed additive manufacturing techniques: stereolithography (SL), multi-jet modelling (MJM), selective laser melting (SLM), laser sintering (LS) and fused deposition modelling (FDM) were used to manufacture a number of miniaturised reactors which were tested using a range of organic and inorganic reactions.

  3. Power electronic modules design and manufacture

    CERN Document Server

    Sheng, William W

    2004-01-01

    IntroductionSelection ProcedureMaterialsInsulating Substrate and MetallizationBase PlateBonding MaterialPower Interconnection and TerminalEncapsulantPlastic Case and Cover Manufacturing of Power IGBT ModulesManufacturing Process Process Control/Long-Term ReliabilityManufacturing FacilitiesManufacturing Flow Charts DesignThermal ManagementCircuit PartitioningDesign Guidelines and ConsiderationsThermal Results of Different Samples

  4. Manufacturing of Smart Structures Using Fiber Placement Manufacturing Processes

    Science.gov (United States)

    Thomas, Matthew M.; Glowasky, Robert A.; McIlroy, Bruce E.; Story, Todd A.

    1996-01-01

    Smart structures research and development, with the ultimate aim of rapid commercial and military production of these structures, are at the forefront of the Synthesis and Processing of Intelligent Cost-Effective Structures (SPICES) program. As part of this ARPA-sponsored program, MDA-E is using fiber placement processes to manufacture integrated smart structure systems. These systems comprise advanced composite structures with embedded fiber optic sensors, shape memory alloys, piezoelectric actuators, and miniature accelerometers. Cost-effective approaches and solutions to smart material synthesis in the fiber-placement process, based upon integrated product development, are discussed herein.

  5. Registered manufacturers of renewable energy devices

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Registered manufacturers of renewable energy devices in India are listed. The list is arranged under the headings : solar water heating system, solar cooker, solar still and water pumping wind mill. In all 38 manufacturers are listed. The list gives the postal address, name of the contact person and phone number of each manufacturer. (M.G.B.)

  6. Manufacturing: the new case for vertical integration

    NARCIS (Netherlands)

    Kumpe, Ted; Bolwijn, Piet

    1988-01-01

    The article argues that the solid corporation will continue to view vertical integration as a critical part of manufacturing reform. Manufacturing reform and backward integration are related in insidious ways to the three stages of production over which the big manufacturers preside. Without

  7. The manufacturing role in fuel performance

    International Nuclear Information System (INIS)

    Barr, A.P.

    1997-01-01

    Manufacturing companies have been involved in the CANDU fuel industry for more than 40 years. Early manufacturing contributions were the development of materials and processes used to fabricate the CANDU fuel bundle. As CANDU reactors were commissioned, the manufacturing contribution has been to produce economical, high quality fuel for the CANDU market. (author)

  8. 19 CFR 11.2 - Manufactured tobacco.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Manufactured tobacco. 11.2 Section 11.2 Customs... PACKING AND STAMPING; MARKING Packing and Stamping § 11.2 Manufactured tobacco. (a) If the invoice and entry presented for manufactured tobacco specify all the information necessary for prompt determination...

  9. Handbook of manufacturing engineering and technology

    CERN Document Server

    2015-01-01

    The Springer Reference Work Handbook of Manufacturing Engineering and Technology provides overviews and in-depth and authoritative analyses on the basic and cutting-edge manufacturing technologies and sciences across a broad spectrum of areas. These topics are commonly encountered in industries as well as in academia. Manufacturing engineering curricula across universities are now essential topics covered in major universities worldwide.

  10. Assembly-Line Manufacturing Industry Simulation

    Science.gov (United States)

    Chamberlain, R. G.; Firnett, P. J.

    1985-01-01

    Assists in economic analysis of production line manufacturing. Originally developed to estimate product price received by hypothetical U.S. industry that manufactures silicon solar modules for use in electricity generation, SAMIS extended and generalized to extent that it simulates operation of many different production line manufacturing industries and/or companies.

  11. Manufacturing technologies of PWR pressure vessels

    International Nuclear Information System (INIS)

    Qin Xubin

    1991-01-01

    Pressure vessels belong to the main component of PWR plants. Starting with describing the manufacture of pressure vessel components and their assembly, the manufacturing technologies of pressure vessels are briefly presented with regards to welding, heat treatment, inspections and testing. In addition, quality assurance during the manufacture is presented with emphasis

  12. Material Database for Additive Manufacturing Techniques

    Science.gov (United States)

    2017-12-01

    TECHNICAL REPORT RDMR-WD-17-64 MATERIAL DATABASE FOR ADDITIVE MANUFACTURING TECHNIQUES Janice C. Booth Weapons Development...Final 4. TITLE AND SUBTITLE Material Database for Additive Manufacturing Techniques 5. FUNDING NUMBERS 6. AUTHOR(S) Janice C...ABSTRACT (Maximum 200 Words) This report details material testing and results for a set of materials used in additive manufacturing for the

  13. Determination of ultraviolet cosine-corrected irradiances and aerosol optical thickness by combined measurements with a Brewer spectrophotometer and a multifilter rotating shadowband radiometer.

    Science.gov (United States)

    di Sarra, Alcide; Fua, Daniele; Cacciani, Marco; Di Iorio, Tatiana; Disterhoft, Patrick; Meloni, Daniela; Monteleone, Francesco; Piacentino, Salvatore; Sferlazzo, Damiano

    2008-11-20

    Combined measurements of diffuse-to-global radiation ratio and global spectral irradiances in the UV are used to derive cosine-corrected UV irradiances and aerosol optical depth (AOD). The diffuse-to-global radiation ratio is used first in the cosine correction of the global irradiance, then to calculate absolutely calibrated direct irradiances. The Beer-Lambert law is applied to derive the UV AOD using independent measurements of the extraterrestrial solar flux. The AOD can be derived with an uncertainty of about 0.03 at 60 degrees solar zenith angle. The method was applied to measurements obtained with two UV multifilter rotating shadowband radiometers (UV-MFRSRs) and a MK III Brewer spectrophotometer on the Island of Lampedusa in the Central Mediterranean during two periods of 2002 and 2004. The derived AOD at 318 and 332 nm was compared with UV AOD measured at 318, 320, and 368 nm with different techniques. The retrieved AOD, combining MFRSR and Brewer measurements, is in good agreement with the optical depth derived with the other methods.

  14. Assessing Single Particle Soot Photometer and Integrating Sphere/Integrating Sandwich Spectrophotometer measurement techniques for quantifying black carbon concentration in snow

    Directory of Open Access Journals (Sweden)

    J. P. Schwarz

    2012-11-01

    Full Text Available We evaluate the performance of the Single Particle Soot Photometer (SP2 and the Integrating Sphere/Integrating Sandwich Spectrophotometer (ISSW in quantifying the concentration of refractory black carbon (BC in snow samples. We find that the SP2 can be used to measure BC mass concentration in snow with substantially larger uncertainty (60% than for atmospheric sampling (<30%. Achieving this level of accuracy requires careful assessment of nebulizer performance and SP2 calibration with consideration of the fact that BC in snow can exist in larger sizes than typically observed in the atmosphere. Once these issues are addressed, the SP2 is able to measure the size distribution and mass concentration of BC in the snow. Laboratory comparison of the SP2 and the ISSW revealed significant biases in the estimate of BC concentration from the ISSW when test samples contained dust or non-absorbing particulates. These results suggest that current estimates of BC mass concentration in snow or ice formed from fallen snow using either the SP2 or the ISSW may be associated with significant underestimates of uncertainty.

  15. In situ analysis of proteins at high temperatures mediated by capillary-flow hydrothermal UV-vis spectrophotometer with a water-soluble chromogenic reagent.

    Science.gov (United States)

    Kawamura, Kunio; Nagayoshi, Hiroki; Yao, Toshio

    2010-05-14

    In situ monitoring of quantities, interactions, and conformations of proteins is essential for the study of biochemistry under hydrothermal environments and the analysis of hyperthermophilic organisms in natural hydrothermal systems on Earth. We have investigated the potential of a capillary-flow hydrothermal UV-vis spectrophotometer (CHUS) for performing in situ measurements of proteins and determining their behavior at extremely high temperatures, in combination with a chromogenic reagents probe, which interacts with the proteins. The spectral shift obtained using a combination of water-soluble porphyrin (TPPS) and bovine serum albumin (BSA) was the best among the spectral shifts obtained using different combinations of chromogenic reagents and proteins. The association behavior of TPPS with BSA was investigated in detail using CHUS at temperatures up to 175 degrees C and the association constant (K(ass)) of TPPS with BSA was successfully determined at temperatures up to 100 degrees C. The lnK(ass) values were inversely proportional to the T(-1) values in the temperature range 50-100 degrees C. These analyses showed for the first time that the decrease of association of TPPS with BSA is due to the conformational change, fragmentation, and/or denaturing of BSA rather than the decrease of the hydrophobic association between TPPS and BSA. This study conclusively demonstrates the usability of the CHUS system with a chromogenic reagent as an in situ detection and measurement system for thermostable proteins at extremely high temperatures. Copyright 2010 Elsevier B.V. All rights reserved.

  16. Spectroscopic studies of model photo-receptors: validation of a nanosecond time-resolved micro-spectrophotometer design using photoactive yellow protein and α-phycoerythrocyanin.

    Science.gov (United States)

    Purwar, Namrta; Tenboer, Jason; Tripathi, Shailesh; Schmidt, Marius

    2013-09-13

    Time-resolved spectroscopic experiments have been performed with protein in solution and in crystalline form using a newly designed microspectrophotometer. The time-resolution of these experiments can be as good as two nanoseconds (ns), which is the minimal response time of the image intensifier used. With the current setup, the effective time-resolution is about seven ns, determined mainly by the pulse duration of the nanosecond laser. The amount of protein required is small, on the order of 100 nanograms. Bleaching, which is an undesirable effect common to photoreceptor proteins, is minimized by using a millisecond shutter to avoid extensive exposure to the probing light. We investigate two model photoreceptors, photoactive yellow protein (PYP), and α-phycoerythrocyanin (α-PEC), on different time scales and at different temperatures. Relaxation times obtained from kinetic time-series of difference absorption spectra collected from PYP are consistent with previous results. The comparison with these results validates the capability of this spectrophotometer to deliver high quality time-resolved absorption spectra.

  17. Effect of vital bleaching with solutions containing different concentrations of hydrogen peroxide and pineapple extract as an additive on human enamel using reflectance spectrophotometer: Anin vitrostudy.

    Science.gov (United States)

    Vejai Vekaash, Chitra Janardhanan; Kumar Reddy, Tripuravaram Vinay; Venkatesh, Kondas Vijay

    2017-01-01

    This study aims to evaluate the color change in human enamel bleached with three different concentrations of hydrogen peroxide, containing pineapple extract as an additive in two different timings, using reflectance spectrophotometer. The study aimed to investigate the bleaching efficacy on natural teeth using natural enzymes. Baseline color values of 10 randomly selected artificially stained incisors were obtained. The specimens were divided into three groups of 20 teeth each: Group 1 - 30% hydrogen peroxide, Group II - 20% hydrogen peroxide, and Group III - 10% hydrogen peroxide. One half of the tooth was bleached with hydrogen peroxide, and other was bleached with hydrogen peroxide and pineapple extract for 20 min (Subgroup A) and 10 min (Subgroup B). The results were statistically analyzed using student's t -test. The mean ΔE values of Group IA (31.62 ± 0.9), Group IIA (29.85 ± 1.2), and Group IIIA (28.65 ± 1.2) showed statistically significant higher values when compared to the mean Δ E values of Group 1A (25.02 ± 1.2), Group IIA (22.86 ± 1.1), and Group IIIA (16.56 ± 1.1). Identical results were obtained in Subgroup B. The addition of pineapple extract to hydrogen peroxide resulted in effective bleaching.

  18. [Variation in soil Mn fractions as affected by long-term manure amendment using atomic absorption spectrophotometer in a typical grassland of inner Mongolia].

    Science.gov (United States)

    Fu, Ming-ming; Jiang, Yong; Bai, Yong-fei; Zhang, Yu-ge; Xu, Zhu-wen; Li, Bo

    2012-08-01

    The effect of sheep manure amendment on soil manganese fractions was conducted in a 11 year experiment at inner Mongolia grassland, using sequential extraction procedure in modified Community Bureau of Reference, and determined by atomic absorption spectrophotometer. Five treatments with dry sheep manure addition rate 0, 50, 250, 750, and 1500 g x m(-2) x yr(-1), respectively, were carried out in this experiment. Results showed that the recovery rate for total Mn was 91.4%-105.9%, as the percentage recovered from the summation of the improved BCR results with aqua regia extractable contents, and it was 97.2%-102.9% from certified soil reference materials. Plant available exchangeable Mn could be enhanced by 47.89%, but reducible and total Mn contents decreased significantly under heavy application of manure at depth of 0-5 cm. The effect of manure amendment on Mn fractions was greater in 0-5 cm than in 5-10 cm soil layer. The results are benefit to micronutrient fractions determination and nutrient management in grassland soils.

  19. Influence of Light Conditions and Light Sources on Clinical Measurement of Natural Teeth Color using VITA Easyshade Advance 4,0®Spectrophotometer. Pilot Study.

    Science.gov (United States)

    Posavec, Ivona; Prpić, Vladimir; Zlatarić, Dubravka Knezović

    2016-12-01

    The purpose of this study was to evaluate and compare lightness (L), chroma (C) and hue (h), green-red (a) and blue-yellow (b) character of the color of maxillary right central incisors in different light conditions and light sources. Two examiners who were well trained in digital color evaluation participated in the research. Intraclass correlation coefficients (ICCs) were used to analyze intra- and interobserver reliability. The LCh and L*a*b* values were determined at 08.15 and at 10.00 in the morning under three different light conditions. Tooth color was assessed in 10 subjects using intraoral spectrophotometer VITA Easyshade Advance 4.0 ® set at the central region of the vestibular surface of the measured tooth. Intra- and interobserver ICC values were high for both examiners and ranged from 0.57 to 0.99. Statistically significant differences in LCh and L*a*b* values measured in different time of the day and certain light condition were not found (p>0.05). Statistically significant differences in LCh and L*a*b* values measured under three different light conditions were not found, too (p>0.05). VITA Easyshade Advance 4.0 ® is reliable enough for daily clinical work in order to assess tooth color during the fabrication of esthtic appliances because it is not dependent on light conditions and light sources.

  20. iHWG-μNIR: a miniaturised near-infrared gas sensor based on substrate-integrated hollow waveguides coupled to a micro-NIR-spectrophotometer.

    Science.gov (United States)

    Rohwedder, J J R; Pasquini, C; Fortes, P R; Raimundo, I M; Wilk, A; Mizaikoff, B

    2014-07-21

    A miniaturised gas analyser is described and evaluated based on the use of a substrate-integrated hollow waveguide (iHWG) coupled to a microsized near-infrared spectrophotometer comprising a linear variable filter and an array of InGaAs detectors. This gas sensing system was applied to analyse surrogate samples of natural fuel gas containing methane, ethane, propane and butane, quantified by using multivariate regression models based on partial least square (PLS) algorithms and Savitzky-Golay 1(st) derivative data preprocessing. The external validation of the obtained models reveals root mean square errors of prediction of 0.37, 0.36, 0.67 and 0.37% (v/v), for methane, ethane, propane and butane, respectively. The developed sensing system provides particularly rapid response times upon composition changes of the gaseous sample (approximately 2 s) due the minute volume of the iHWG-based measurement cell. The sensing system developed in this study is fully portable with a hand-held sized analyser footprint, and thus ideally suited for field analysis. Last but not least, the obtained results corroborate the potential of NIR-iHWG analysers for monitoring the quality of natural gas and petrochemical gaseous products.

  1. Determination of arsenic concentration in tiger tooth croaker (Otolithes ruber and indian halibut (Psettodes erumei using hydride generation atomic absorption spectrophotometer

    Directory of Open Access Journals (Sweden)

    E Rahimi

    2011-11-01

    Full Text Available Heavy metal contaminants in fish are of particular interest because of their potential risk to human. This study was undertaken to determine the levels of arsenic in two fish type including tiger tooth croaker and Indian halibut  in Esfahan. A total of 42 fish samples including 28 tiger tooth croaker (Otolithes ruber and 14 Indian halibut (Psettodes erumei were collected from retails of Esfahan from May 2010 to January 2011. For detection of arsenic contamination, the edible muscles of  fish samples were analyzed by hydride generation atomic absorption spectrophotometer. The arsenic contamination in fish samples were found to be in the range of 11 to 98 µg/kg. Concentration of arsenic in tiger tooth croaker and Indian halibut was 11-56 and 32-98 µg/kg, respectively. Arsenic concentrations were below the limit was acceptable to the World Health Organization. According to the results, the concentration of arsenic did not exceed the maximum acceptable intake limit.

  2. Determination of Traces of Pd(II in Spiked Samples by Using 3,4-Dihydroxybenzaldehydeisonicotinol-hydrazone as a Chelating Agent with UV Visible Spectrophotometer

    Directory of Open Access Journals (Sweden)

    S. Lakshmi Narayana

    2011-01-01

    Full Text Available A simple, rapid, sensitive and inexpensive method has been developed for the determination of trace amounts of palladium(II using 3,4-dihydroxybenzaldehydeisonicotinoylhydrazone (3,4-DHBINH. The metal ion gives a yellow colored complex with 3,4-DHBINH in acetate buffer of pH 3.0 with 1:1 (metal: ligand composition. The complex shows maximum absorption at 380 nm. Beer’s law is obeyed in the range 0.5-20.0 ppm of Pd(II. The molar absorptivity, Sandell’s sensitivity and detection limit were found to be 0.53×104 L mol-1 cm-1, 0.02 μg cm-2 and 0.0948 μg mL-1, respectively. The correlation coefficient and regression coefficient of the Pd(II-3,4-DHBINH complex were 1.08 and 0.04 respectively. Major cations and anions did not show any interference. Anti-microbial activity of the Pd(II-3,4-DHBINH has been studied. The developed method has been successfully applied to the analysis of Pd(II in spiked samples. Comparing the results with those obtained using an atomic absorption spectrophotometer tested the validity of the method

  3. Ohio Advanced Energy Manufacturing Center

    Energy Technology Data Exchange (ETDEWEB)

    Kimberly Gibson; Mark Norfolk

    2012-07-30

    The program goal of the Ohio Advanced Energy Manufacturing Center (OAEMC) is to support advanced energy manufacturing and to create responsive manufacturing clusters that will support the production of advanced energy and energy-efficient products to help ensure the nation's energy and environmental security. This goal cuts across a number of existing industry segments critical to the nation's future. Many of the advanced energy businesses are starting to make the transition from technology development to commercial production. Historically, this transition from laboratory prototypes through initial production for early adopters to full production for mass markets has taken several years. Developing and implementing manufacturing technology to enable production at a price point the market will accept is a key step. Since these start-up operations are configured to advance the technology readiness of the core energy technology, they have neither the expertise nor the resources to address manufacturing readiness issues they encounter as the technology advances toward market entry. Given the economic realities of today's business environment, finding ways to accelerate this transition can make the difference between success and failure for a new product or business. The advanced energy industry touches a wide range of industry segments that are not accustomed to working together in complex supply chains to serve large markets such as automotive and construction. During its first three years, the Center has catalyzed the communication between companies and industry groups that serve the wide range of advanced energy markets. The Center has also found areas of common concern, and worked to help companies address these concerns on a segment or industry basis rather than having each company work to solve common problems individually. EWI worked with three industries through public-private partnerships to sew together disparate segments helping to promote

  4. Method for automatically evaluating a transition from a batch manufacturing technique to a lean manufacturing technique

    Science.gov (United States)

    Ivezic, Nenad; Potok, Thomas E.

    2003-09-30

    A method for automatically evaluating a manufacturing technique comprises the steps of: receiving from a user manufacturing process step parameters characterizing a manufacturing process; accepting from the user a selection for an analysis of a particular lean manufacturing technique; automatically compiling process step data for each process step in the manufacturing process; automatically calculating process metrics from a summation of the compiled process step data for each process step; and, presenting the automatically calculated process metrics to the user. A method for evaluating a transition from a batch manufacturing technique to a lean manufacturing technique can comprise the steps of: collecting manufacturing process step characterization parameters; selecting a lean manufacturing technique for analysis; communicating the selected lean manufacturing technique and the manufacturing process step characterization parameters to an automatic manufacturing technique evaluation engine having a mathematical model for generating manufacturing technique evaluation data; and, using the lean manufacturing technique evaluation data to determine whether to transition from an existing manufacturing technique to the selected lean manufacturing technique.

  5. A method for manufacturing compacts

    International Nuclear Information System (INIS)

    Baschwitz, Robert; Raymond, Jean.

    1974-01-01

    Description is given of a method for preparing compacts with high matrix density. The method is characterized by the steps of forming the mixture by simultaneously pouring the components directly into a compacting matrix comprising coated particles and a graphite binder mixture in the granular form, then compressing the compact after having brought the material to be compacted to a temperature at which the binder is in the fluid state. The method can be applied to the manufacture of compacts for high temperature nuclear reactors [fr

  6. Development of Integration in Manufacturing

    DEFF Research Database (Denmark)

    Sørensen, Torben; Trostmann, Erik

    1996-01-01

    Current international developments in the broad field of Product Data Technology are advancing rapidly and are leading up to new levels of technology in product model definition, product model communications, enterprise integration and cooperation. These developments will be of strategic...... significance to all manufacturing industries.International standardization based on the product model definition standard STEP (ISO10303) is playing a key role in promoting a modern approach to Product Data Technology. The initial release of STEP, consisting of twelve essential parts, has recently been...

  7. Manufacturing in the knowledge economy

    DEFF Research Database (Denmark)

    Hansen, Teis; Winther, Lars

    2015-01-01

    Recent studies stress the relevance of a broad conceptualization of the knowledge economy which goes beyond the strong, current policy focus on high-tech industries. Today, low-tech industries continue to have a significant role in European manufacturing in terms of employment, value added......-tech industries. This calls for a rethinking of manufacturing’s position in contemporary capitalism and a redefinition of the central categories based on research and development (R & D) intensity that dominate the debate on the knowledge economy....

  8. A method for manufacturing monocrystals

    International Nuclear Information System (INIS)

    Faure, Jacqueline; Malmejac, Yves; Schaub, Bernard.

    1973-01-01

    Description is given of a method for manufacturing monocrystals, substantially free of disorder, of a metal showing an allotropic transformation at a temperature lower than its melting point. Monocrystals of the raw metal having undergone a uni-directional solidification are heated to a temperature between the allotropic transformation point and the metal melting point; the monocrystals are maintained in the vicinity of that temperature for a given period of time; they are cooled down to a temperature lower than the allotropic transformation point, then they are annealed and cooled down to room temperature. Such monocrystals are used in neutron monochromators [fr

  9. Borated aluminum alloy manufacturing technology

    International Nuclear Information System (INIS)

    Shimojo, Jun; Taniuchi, Hiroaki; Kajihara, Katsura; Aruga, Yasuhiro

    2003-01-01

    Borated aluminum alloy is used as the basket material of cask because of its light weight, thermal conductivity and superior neutron absorbing abilities. Kobe Steel has developed a unique manufacturing process for borated aluminum alloy using a vacuum induction melting method. In this process, aluminum alloy is melted and agitated at higher temperatures than common aluminum alloy fabrication methods. It is then cast into a mold in a vacuum atmosphere. The result is a high quality aluminum alloy which has a uniform boron distribution and no impurities. (author)

  10. Additive Manufacturing of Porous Metal

    Energy Technology Data Exchange (ETDEWEB)

    Dehoff, Ryan R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Kirka, Michael M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-06-01

    Currently, helium is obtained through separation from natural gas. The current industrial process incurs significant costs and requires large energy resources to successfully achieve separation. Through utilizing Additive Manufacturing (AM) technologies it is possible to reduce both of these burdens when refining helium gas. The ability to engineer porosity levels within Inconel 718 discs for controlled separation of helium from natural gas was investigated. Arrays of samples fabricated using the electron beam melting process were analyzed for their relative porosity density. Based upon the measurements, full scale discs were fabricated, and subsequently tested to determine their effectiveness in separating helium from liquefied natural gas.

  11. Contemporary design and manufacturing technology

    CERN Document Server

    Wang, Taiyong; Zuo, Dunwen

    2013-01-01

    The special topic volume communicates the latest progress and research results of new theory, new technology, method, equipment and so on in Engineering Technology, and to grasp the updated technological and research trends in internationally. The major topics covered by the special volumes include Advanced Materials and Manufacturing Technologies, Control, Automation and Detection Systems, Advanced Design Technology, Optimization and Modeling. In 80 invited and peer-reviewed papers, mechanical and other engineers describe their recent and current research and results in advanced materials and

  12. Credit demand in Mozambican manufacturing

    DEFF Research Database (Denmark)

    Byiers, Bruce; Rand, John; Tarp, Finn

    2010-01-01

    This paper uses two industrial firm surveys to identify the key determinants of credit demand in Mozambican manufacturing. We construct five different measures of being credit constrained and estimate desired debt demand. Besides firm size and ownership structure, we find evidence that general...... manager education and business association membership are associated with whether a firm is credit constrained or not. Using our preferred measure of credit constraint suggests that around 43 per cent of the firms surveyed are constrained, and these enterprises would almost triple their debt burden...

  13. Another Program Simulates A Modular Manufacturing System

    Science.gov (United States)

    Schroer, Bernard J.; Wang, Jian

    1996-01-01

    SSE5 computer program provides simulation environment for modeling manufacturing systems containing relatively small numbers of stations and operators. Designed to simulate manufacturing of apparel, also used in other manufacturing domains. Valuable for small or medium-size firms, including those lacking expertise to develop detailed mathematical models or have only minimal knowledge in describing manufacturing systems and in analyzing results of simulations on mathematical models. Two other programs available bundled together as SSE (MFS-26245). Each program models slightly different manufacturing scenario. Written in Turbo C v2.0 for IBM PC-series and compatible computers running MS-DOS and successfully compiled using Turbo C++ v3.0.

  14. Cloud manufacturing: from concept to practice

    Science.gov (United States)

    Ren, Lei; Zhang, Lin; Tao, Fei; Zhao, Chun; Chai, Xudong; Zhao, Xinpei

    2015-02-01

    The concept of cloud manufacturing is emerging as a new promising manufacturing paradigm, as well as a business model, which is reshaping the service-oriented, highly collaborative, knowledge-intensive and eco-efficient manufacturing industry. However, the basic concepts about cloud manufacturing are still in discussion. Both academia and industry will need to have a commonly accepted definition of cloud manufacturing, as well as further guidance and recommendations on how to develop and implement cloud manufacturing. In this paper, we review some of the research work and clarify some fundamental terminologies in this field. Further, we developed a cloud manufacturing systems which may serve as an application example. From a systematic and practical perspective, the key requirements of cloud manufacturing platforms are investigated, and then we propose a cloud manufacturing platform prototype, MfgCloud. Finally, a public cloud manufacturing system for small- and medium-sized enterprises (SME) is presented. This paper presents a new perspective for cloud manufacturing, as well as a cloud-to-ground solution. The integrated solution proposed in this paper, including the terminology, MfgCloud, and applications, can push forward this new paradigm from concept to practice.

  15. Selected Applications of Virtual Reality in Manufacturing

    Science.gov (United States)

    Novak-Marcincin, Jozef

    2011-01-01

    Virtual reality (VR) has become an important and useful tool in science and engineering. VR applications cover a wide range of industrial areas from product design to analysis, from product prototyping to manufacturing. The design and manufacturing of a product can be viewed, evaluated and improved in a virtual environment before its prototype is made, which is an enormous cost saving. Virtual Manufacturing (VM) is the use of computer models and simulations of manufacturing processes to aid in the design and production of manufactured products. VM is the use of manufacturing-based simulations to optimize the design of product and processes for a specific manufacturing goal such as: design for assembly; quality; lean operations; and/or flexibility.

  16. Challenges in teaching modern manufacturing technologies

    Science.gov (United States)

    Ngaile, Gracious; Wang, Jyhwen; Gau, Jenn-Terng

    2015-07-01

    Teaching of manufacturing courses for undergraduate engineering students has become a challenge due to industrial globalisation coupled with influx of new innovations, technologies, customer-driven products. This paper discusses development of a modern manufacturing course taught concurrently in three institutions where students collaborate in executing various projects. Lectures are developed to contain materials featuring advanced manufacturing technologies, R&D trends in manufacturing. Pre- and post-surveys were conducted by an external evaluator to assess the impact of the course on increase in student's knowledge of manufacturing; increase students' preparedness and confidence in effective communication and; increase students' interest in pursuing additional academic studies and/or a career path in manufacturing and high technology. The surveyed data indicate that the students perceived significant gains in manufacturing knowledge and preparedness in effective communication. The study also shows that implementation of a collaborative course within multiple institutions requires a robust and collective communication platform.

  17. EMERGENCE OF SIMULATIONS FOR MANUFACTURING LINE DESIGNS IN JAPANESE AUTOMOBILE MANUFACTURING PLANTS

    OpenAIRE

    Nguyen, Minh Dang; Takakuwa, Soemon

    2008-01-01

    The aim of this research is to introduce the reader to a new perspective on the framework for designing a manufacturing line project in Japanese automobile manufacturing plants. All manufacturing aspects, manual, automated and hybrid manufacturing lines are considered; however, which line should be used for the factory is always under investigation within the factory. Simulation studies that include resource utilization, line productivity and manufacturing costs help to identify the most suit...

  18. [Stress management in manufacturing industries].

    Science.gov (United States)

    Watanabe, Misuzu

    2003-01-01

    Job strain factors and stress management for workers in the manufacturing industries were reviewed in this article. Major job stress factors included high job demands, low job control, low social support, role ambiguity and conflict, the physical, chemical and ergonomics of the work environment, work patterns with work schedule and shift work, and job insecurity regarding future employment. In considering effective stress management plans which counteract the job stress factors mentioned above, it is essential to use an organizational approach in the work environment. For workers in the manufacturing industry, through this approach, it is important to promote more autonomy and activities with increasing job control, to give more clarified roles and responsibilities, to provide a more mutually supportive system with better ways to communicate and to introduce a system giving additional rewards, such as paid holidays for refreshment. Plans are also needed for individuals and groups, such as workers, managers, supervisors and workgroups, regarding education, skill training and mutual training according to the personnel characteristics of each target. In order to make these stress management plans successful in the long term, an actual system for stress management is required, with recognition and support by top management. It is also important to assess the effectiveness and method of each stress management plan with proper measurements.

  19. Fugitive emissions from nanopowder manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Trompetter, W. J., E-mail: b.trompetter@gns.cri.nz; Ancelet, T.; Davy, P. K.; Kennedy, J. [GNS Science (New Zealand)

    2016-07-15

    In response to health and safety questions and concerns regarding particulate matter emissions from equipment used for synthesizing NiFe and TiO{sub 2} nanopowders, a study was undertaken to assess their impact on the air quality inside and outside a laboratory where the manufacturing equipment is operated. Elemental concentrations determined by ion beam analysis (IBA) of air particulate matter (PM) samples collected hourly with a Streaker{sup TM} sampler were used to identify possible sources and estimate contributions from nanopowder production and other sources. The fugitive nanopowder emissions were the highest at the indoor sampling location when powders were being manufactured. Average fugitive emissions of 210 ng m{sup −3} (1-h average) (maximum 2163 ng m{sup −3} 1-h average) represented 2 % (maximum 20 %) of the average PM collected (9359 ng m{sup −3} 1-h average). The measured NiFe alloy or TiO{sub 2} PM concentrations were much smaller than the 8-h time-weighted average (TWA) workplace exposure standards (WES) for these materials (≥1,000,000 ng m{sup −3}). Most PM was found to be from infiltrated outdoor ambient sources. This suggests that nanopowder production in the laboratory is not likely to have adverse health effects on individuals using the equipment, although further improvements can be made to further limit exposure.Graphical abstract.

  20. Additive manufacturing of RF absorbers

    Science.gov (United States)

    Mills, Matthew S.

    The ability of additive manufacturing techniques to fabricate integrated electromagnetic absorbers tuned for specific radio frequency bands within structural composites allows for unique combinations of mechanical and electromagnetic properties. These composites and films can be used for RF shielding of sensitive electromagnetic components through in-plane and out-of-plane RF absorption. Structural composites are a common building block of many commercial platforms. These platforms may be placed in situations in which there is a need for embedded RF absorbing properties along with structural properties. Instead of adding radar absorbing treatments to the external surface of existing structures, which adds increased size, weight and cost; it could prove to be advantageous to integrate the microwave absorbing properties directly into the composite during the fabrication process. In this thesis, a method based on additive manufacturing techniques of composites structures with prescribed electromagnetic loss, within the frequency range 1 to 26GHz, is presented. This method utilizes screen printing and nScrypt micro dispensing to pattern a carbon based ink onto low loss substrates. The materials chosen for this study will be presented, and the fabrication technique that these materials went through to create RF absorbing structures will be described. The calibration methods used, the modeling of the RF structures, and the applications in which this technology can be utilized will also be presented.

  1. Manufacturers' support to plant operation

    International Nuclear Information System (INIS)

    Kuschel, D.

    1996-01-01

    For more than 30 years now, safety and availablity of German nuclear power plants has been a common interest of the plant owners and the manufacturing company KWU. This longstanding collaboration for a common goal has created a safety culture unprecented in other countries, and a partnership worth to be continued. Due to the nuclear power phaseout policy, the priority today is on maintaining and safeguarding economically efficient operation of existing power plants. KWU have been adapting their business strategy to the change in the market, and are prepared to stick to this line. Thus KWU and plant operators see to it that the acquired competence in nuclear power plant technology will remain to be concentrated in the hands of the manufacturers. Continuing the partnership in this field, and encouraged by the placement of orders for the future EPR and the SWR 1000, KWU and plant operators will be in the position to offer a sound option for future decisions about construction of new nuclear power plants in Germany. (orig.) [de

  2. Membrane manufacture for peptide separations

    KAUST Repository

    Kim, Dooli

    2016-06-07

    Nanostructured polymeric membranes are key tools in biomedical applications such as hemodialysis, protein separations, in the food industry, and drinking water supply from seawater. Despite of the success in different separation processes, membrane manufacture itself is at risk, since the most used solvents are about to be banned in many countries due to environmental and health issues. We propose for the first time the preparation of polyethersulfone membranes based on dissolution in the ionic liquid 1-ethyl-3-methylimidazolium dimethylphosphate ([EMIM]DEP). We obtained a series of membranes tailored for separation of solutes with molecular weight of 30, 5, 1.3, and 1.25 kg mol-1 with respective water permeances of 140, 65, 30 and 20 Lm-2h-1bar-1. We demonstrate their superior efficiency in the separation of complex mixtures of peptides with molecular weights in the range of 800 to 3500 gmol-1. Furthermore, the thermodynamics and kinetics of phase separation leading to the pore formation in the membranes were investigated. The rheology of the solutions and the morphology of the prepared membranes were examed and compared to those of polyethersulfone in organic solvents currently used for membrane manufacture.

  3. Mechanics of additively manufactured biomaterials.

    Science.gov (United States)

    Zadpoor, Amir A

    2017-06-01

    Additive manufacturing (3D printing) has found many applications in healthcare including fabrication of biomaterials as well as bioprinting of tissues and organs. Additively manufactured (AM) biomaterials may possess arbitrarily complex micro-architectures that give rise to novel mechanical, physical, and biological properties. The mechanical behavior of such porous biomaterials including their quasi-static mechanical properties and fatigue resistance is not yet well understood. It is particularly important to understand the relationship between the designed micro-architecture (topology) and the resulting mechanical properties. The current special issue is dedicated to understanding the mechanical behavior of AM biomaterials. Although various types of AM biomaterials are represented in the special issue, the primary focus is on AM porous metallic biomaterials. As a prelude to this special issue, this editorial reviews some of the latest findings in the mechanical behavior of AM porous metallic biomaterials so as to describe the current state-of-the-art and set the stage for the other studies appearing in the issue. Some areas that are important for future research are also briefly mentioned. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Literature Review on Dynamic Cellular Manufacturing System

    Science.gov (United States)

    Nouri Houshyar, A.; Leman, Z.; Pakzad Moghadam, H.; Ariffin, M. K. A. M.; Ismail, N.; Iranmanesh, H.

    2014-06-01

    In previous decades, manufacturers faced a lot of challenges because of globalization and high competition in markets. These problems arise from shortening product life cycle, rapid variation in demand of products, and also rapid changes in manufcaturing technologies. Nowadays most manufacturing companies expend considerable attention for improving flexibility and responsiveness in order to overcome these kinds of problems and also meet customer's needs. By considering the trend toward the shorter product life cycle, the manufacturing environment is towards manufacturing a wide variety of parts in small batches [1]. One of the major techniques which are applied for improving manufacturing competitiveness is Cellular Manufacturing System (CMS). CMS is type of manufacturing system which tries to combine flexibility of job shop and also productivity of flow shop. In addition, Dynamic cellular manufacturing system which considers different time periods for the manufacturing system becomes an important topic and attracts a lot of attention to itself. Therefore, this paper made attempt to have a brief review on this issue and focused on all published paper on this subject. Although, this topic gains a lot of attention to itself during these years, none of previous researchers focused on reviewing the literature of that which can be helpful and useful for other researchers who intend to do the research on this topic. Therefore, this paper is the first study which has focused and reviewed the literature of dynamic cellular manufacturing system.

  5. Sorption of Cr(VI) ions on two Lewatit-anion exchange resins and their quantitative determination using UV-visible spectrophotometer.

    Science.gov (United States)

    Pehlivan, E; Cetin, S

    2009-04-15

    The sorption of Cr(VI) from aqueous solutions with macroporous resins which contain quarternary amine groups (Lewatit MP 64 and Lewatit MP 500) was studied at varying Cr(VI) concentration, adsorbent dose, pH, contact time and temperature. Batch shaking sorption experiments were carried out to evaluate the performance of Lewatit MP 64 and Lewatit MP 500 anion exchange resins in the removal of Cr(VI) from aqueous solutions. The concentration of Cr(VI) in aqueous solution was determined by UV-visible spectrophotometer. The ion exchange process, which is dependent on pH, showed maximum removal of Cr(VI) in the pH range 3-7 for an initial Cr(VI) concentration of 1x10(-3) M. The optimum pH for Cr(VI) adsorption was found as 5.0 for Lewatit MP 64 and 6.0 for Lewatit MP 500. The maximum Cr(VI) adsorption at pH 5.0 is 0.40 and 0.41 mmol/g resin for Lewatit MP 64 and Lewatit MP 500 anion exchangers, respectively. The maximum chromium sorption occurred at approximately 60 min for Lewatit MP 64 and 75 min for Lewatit MP 500. The suitability of the Freundlich and Langmuir adsorption models was also investigated for each chromium-sorbent system. The uptake of Cr(VI) by the anion exchange resins was reversible and so it has good potential for the removal of Cr(VI) from aqueous solutions. Both ion exchangers had high bonding constants but Lewatit MP 500 showed stronger binding. The rise in the temperature caused a slight decrease in the value of the equilibrium constant (K(c)) for the sorption of Cr(VI) ion.

  6. Method Performance of Total Mercury (Hg) Testing in the Biological Samples by Using Cold Vapour Atomic Absorption Spectrophotometer (CV-AAS)

    International Nuclear Information System (INIS)

    Susanna TS; Samin

    2007-01-01

    Method performance (validation) of total mercury (Hg) testing in the biological samples by using cold vapour atomic absorption spectrophotometer (CV-AAS) has been done. The objective of this research is to know the method performance of CV-AAS as one of points for the accreditation testing of laboratory according IS0/IEC 17025-2005. The method performance covering limit of detection (LOD), accuracy, precision and bias. As a standard material used SRM Oyster Tissue 15660 from Winopal Forshung Germany, whereas the biological samples were human hair. In principle of mercury testing for solid samples using CV-AAS is dissolving this sample and standard with 10 mL HNO 3 supra pure into a closed quartz tube and heating at 150 °C for 4 hours. The concentration of mercury in each samples was determined at the condition of operation were stirring time (T 1 ) 70 seconds, delay time (T 2 ) 15 seconds, heating time (T 3 ) 13 seconds and cooling time (T 4 ) of 25 seconds. Mercury ion in samples are reduced with SnCl 2 10 % in H 2 SO 4 20 %, and then the vapour of mercury from reduction is passed in NaOH 20 % solution and aquatridest. The result of method performance were: limit of detection (LOD) = 0.085 ng, accuracy 99.70 %, precision (RSD) = 1.64 % and bias = 0.30 %. From the validation result showed that the content of mercury total was in the range of certified values. The total mercury content (Hg) in human hair were varied from 406.93 - 699.07 ppb. (author)

  7. Analysis of Photosystem I Donor and Acceptor Sides with a New Type of Online-Deconvoluting Kinetic LED-Array Spectrophotometer.

    Science.gov (United States)

    Schreiber, Ulrich; Klughammer, Christof

    2016-07-01

    The newly developed Dual/KLAS-NIR spectrophotometer, technical details of which were reported very recently, is used in measuring redox changes of P700, plastocyanin (PC) and ferredoxin (Fd) in intact leaves of Hedera helix, Taxus baccata and Brassica napus An overview of various light-/dark-induced changes of deconvoluted P700 + , PC + and Fd - signals is presented demonstrating the wealth of novel information and the consistency of the obtained results. Fd - changes are particularly large after dark adaptation. PC oxidation precedes P700 oxidation during dark-light induction and in steady-state light response curves. Fd reoxidation during induction correlates with the secondary decline of simultaneously measured fluorescence yield, both of which are eliminated by removal of O 2 By determination of 100% redox changes, relative contents of PC/P700 and Fd/P700 can be assessed, which show considerable variations between different leaves, with a trend to higher values in sun leaves. Based on deconvoluted P700 + signals, the complementary quantum yields of PSI, Y(I) (photochemical energy use), Y(ND) (non-photochemical loss due to oxidized primary donor) and Y(NA) (non-photochemical loss due to reduced acceptor) are determined as a function of light intensity and compared with the corresponding complementary quantum yields of PSII, Y(II) (photochemical energy use), Y(NPQ) (regulated non-photochemical loss) and Y(NO) (non-regulated non-photochemical loss). The ratio Y(I)/Y(II) increases with increasing intensities. In the low intensity range, a two-step increase of PC + is indicative of heterogeneous PC pools. © The Author 2016. Published by Oxford University Press on behalf of Japanese Society of Plant Physiologists. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  8. Online identification of the antioxidant constituents of traditional Chinese medicine formula Chaihu-Shu-Gan-San by LC-LTQ-Orbitrap mass spectrometry and microplate spectrophotometer.

    Science.gov (United States)

    Su, Zhi-Heng; Zou, Guo-An; Preiss, Alfred; Zhang, Hong-Wu; Zou, Zhong-Mei

    2010-11-02

    Chaihu-Shu-Gan-San (CSGS), a traditional Chinese medicine (TCM) formula containing seven herbal medicines, has been used in treatment of gastritis, peptic ulcer, irritable bowel syndrome and depression clinically. However, the chemical constituents in CSGS had not been studied so far. To quickly identify the chemical constituents of CSGS and to understand the chemical profiles related to antioxidant activity of CSGS, liquid chromatography coupled with electrospray ionization hybrid linear trap quadrupole orbitrap (LC-LTQ-Orbitrap) mass spectrometry has been applied for online identification of chemical constituents in complex system, meanwhile, antioxidant profile of CSGS was investigated by the fraction collecting and microplate reading system. As a result, 33 chemical constituents in CSGS were identified. Among them, 13 components could be detected both in positive and in negative ion modes, 20 constituents were determined only in positive ion mode and 2 components were only detected in negative ion mode. Meanwhile, the potential antioxidant profile of CSGS was also characterized by combination of 96-well plate collection of elutes from HPLC analysis and microplate spectrophotometer, in which the scavenging activities of free radical produced by DPPH of each fraction could be directly investigated by the analysis of microplate reader. This study quickly screened the contribution of CSGS fractions to the antioxidant activity and online identified the corresponding active constituents. The results indicated that the combination of LC-MS(n) and 96-well plate assay system established in this paper would be a useful strategy for correlating the chemical profile of TCMs with their bioactivities without isolation and purification. Crown Copyright (c) 2010. Published by Elsevier B.V. All rights reserved.

  9. Influence of manufacturing practices on quality of pharmaceutical ...

    African Journals Online (AJOL)

    Influence of manufacturing practices on quality of pharmaceutical products manufactured in Kenya. ... East African Medical Journal ... industry included the source of raw materials, quarantine procedure before and after manufacture, manufacturing procedure, quality audit, quality assurance procedure, equipment, and staff.

  10. The Relationship between Time Based Management towards Manufacturing Capabilities: Investigating in Malaysian Manufacturing Industries

    Directory of Open Access Journals (Sweden)

    Bin Amlus Mohammad Harith

    2018-01-01

    Full Text Available Towards Industry 4.0, Malaysian Manufacturing Firms need to identify back their manufacturing capabilities especially to increase the performance and profit. This research is conducted to identify the role of manufacturing practices towards manufacturing capabilities. From this information it can provide valuable ingredients for companies in sustainable their operation. The identified factor of manufacturing practices is time based management and the dependent variables is manufacturing capabilities(focusing on agility. Through the survey, a total of 119 firms representing various industries in Northern Region of Malaysia had responded. The hypotheses involved were tested using correlation and regression techniques. The results of the study support the hypotheses. The multiple regression analysis indicates that there are significant relationships among this role on manufacturing capabilities. It is believed that results of this study will be beneficial to the top management of Malaysian manufacturing industries to focus on tim e based management and agility to increase the manufacturing capabilities.

  11. Topology Optimization for Additive Manufacturing

    DEFF Research Database (Denmark)

    Clausen, Anders

    microstructure for a material with programmable, nearly constant Poisson’s ratio for large deformations may be designed and fabricated using direct ink writing. Structures are generated for the full interval [−0.8, 0.8], all with uniform feature size and a continuous print path, ensuring the potential...... for scalable manufacturing. In relation to interface problems it is shown how a flexible void area may be included into a standard minimum compliance problem by employing an additional design variable field and a sensitivity filter. Furthermore, it is shown how the design of coated structures may be modeled...... as a differentiable topology optimization problem. This is done partly by using spatial gradients of the density variable in the interpolation function between the design variable field and physical variables, partly by employing a two-step filtering scheme in order to control the gradient field. The approach...

  12. Exploring Danish Innovative Manufacturing Performance

    DEFF Research Database (Denmark)

    Perunovic, Zoran; Christiansen, Thomas Bøhm

    2005-01-01

    The paper explores several dimensions of Danish industry’s innovative performance with respect to the paradigm of the fifth generation innovation model that was suggested by Rothwell [Int. Market. Rev. 11 (1994) 7]. These dimensions include a general status of innovativeness in Danish companies...... manufacturing companies demonstrate an innovative performance close to the fourth generation of innovation, which is slightly different than it is perceived publicly......., a look at time and cost trade-off, the fifth innovation generation’s related performance and possible congruence between the fifth generation’s factors and motives for their implementation. The source of data is an existing survey ‘The Danish industry—Present and Future’. Results indicate that Danish...

  13. Wind Turbine Manufacturing Process Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Waseem Faidi; Chris Nafis; Shatil Sinha; Chandra Yerramalli; Anthony Waas; Suresh Advani; John Gangloff; Pavel Simacek

    2012-04-26

    To develop a practical inline inspection that could be used in combination with automated composite material placement equipment to economically manufacture high performance and reliable carbon composite wind turbine blade spar caps. The approach technical feasibility and cost benefit will be assessed to provide a solid basis for further development and implementation in the wind turbine industry. The program is focused on the following technology development: (1) Develop in-line monitoring methods, using optical metrology and ultrasound inspection, and perform a demonstration in the lab. This includes development of the approach and performing appropriate demonstration in the lab; (2) Develop methods to predict composite strength reduction due to defects; and (3) Develop process models to predict defects from leading indicators found in the uncured composites.

  14. [Manufactured baby food: safety expectations].

    Science.gov (United States)

    Davin, L; Van Egroo, L-D; Galesne, N

    2010-12-01

    Food safety is a concern for parents of infants, and healthcare professionals are often questioned by them about this topic. Baby food European regulation ensures high levels of safety and is more rigorous than common food regulation. Maximal limit for pesticides in baby food demonstrates the high level of requirements. This limit must be below the 10 ppb detection threshold, whatever the chemical used. Other contaminants such as nitrates are also the subject of greater expectations in baby food. Food safety risks control needs a specific know-how that baby food manufacturers have acquired and experienced, more particularly by working with producers of high quality raw material. Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  15. Josiah Wedgwood, Manufacturing and Craft

    DEFF Research Database (Denmark)

    Holt, Robin; Popp, Andrew

    2016-01-01

    Craft and industrial manufacture are often seen as dichotomous, with craft being marginalized during the process of industrialization. We want to look beyond this position, searching for craft in places where it has gone unnoticed and where it might have bloomed anew in the interstices created...... by industrialization. We explore these questions by studying Josiah Wedgwood’s innovative craft and experimental practices, developed through a close reading of his extensive published correspondence. What we offer is a reinterpretation of Wedgwood’s practices positioned against the existing historiography, both...... standard and revisionist. Our reinterpretation is developed through application of a theoretical–methodological framework of phenomenological micro-history, in which craft is thought of primarily as a space that makes possible what Martin Heidegger called ‘occasioning’....

  16. USCAR LEP ESST Advanced Manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Lazarus, L.J.

    2000-09-25

    The objective of this task was to provide processing information data summaries on powder metallurgy (PM) alloys that meet the partner requirements for the production of low mass, highly accurate, near-net-shape powertrain components. This required modification to existing ISO machinability test procedures and development of a new drilling test procedure. These summaries could then be presented in a web page format. When combined with information generated from the USCAR CRADA this would allow chemical, metallurgical, and machining data on PM alloys to be available to all engineering and manufacturing personnel that have access to in-house networks. The web page format also allows for the additions of other wrought materials, making this a valuable tool to the technical staffs.

  17. An Additive Manufacturing Test Artifact

    Science.gov (United States)

    Moylan, Shawn; Slotwinski, John; Cooke, April; Jurrens, Kevin; Donmez, M Alkan

    2014-01-01

    A test artifact, intended for standardization, is proposed for the purpose of evaluating the performance of additive manufacturing (AM) systems. A thorough analysis of previously proposed AM test artifacts as well as experience with machining test artifacts have inspired the design of the proposed test artifact. This new artifact is designed to provide a characterization of the capabilities and limitations of an AM system, as well as to allow system improvement by linking specific errors measured in the test artifact to specific sources in the AM system. The proposed test artifact has been built in multiple materials using multiple AM technologies. The results of several of the builds are discussed, demonstrating how the measurement results can be used to characterize and improve a specific AM system. PMID:26601039

  18. Additive manufacturing with polypropylene microfibers.

    Science.gov (United States)

    Haigh, Jodie N; Dargaville, Tim R; Dalton, Paul D

    2017-08-01

    The additive manufacturing of small diameter polypropylene microfibers is described, achieved using a technique termed melt electrospinning writing. Sequential fiber layering, which is important for accurate three-dimensional fabrication, was achieved with the smallest fiber diameter of 16.4±0.2μm obtained. The collector speed, temperature and melt flow rate to the nozzle were optimized for quality and minimal fiber pulsing. Of particular importance to the success of this method is appropriate heating of the collector plate, so that the electrostatically drawn filament adheres during the direct-writing process. By demonstrating the direct-writing of polypropylene, new applications exploiting the favorable mechanical, stability and biocompatible properties of this polymer are envisaged. Copyright © 2017. Published by Elsevier B.V.

  19. asan alternative to conventional spectrophotometers

    African Journals Online (AJOL)

    signal whi:h can be processd in a multitude of increasingly complex ways in order to cxtraet as much ehemical information as possible. Apart from the fact that the LEDs are cheap. copact and commercially available, equipment constructed from this system have smalt size. fight weight. low power consumption and negligible ...

  20. A Portable Diode Array Spectrophotometer.

    Science.gov (United States)

    Stephenson, David

    2016-05-01

    A cheap portable visible light spectrometer is presented. The spectrometer uses readily sourced items and could be constructed by anyone with a knowledge of electronics. The spectrometer covers the wavelength range 450-725 nm with a resolution better than 5 nm. The spectrometer uses a diffraction grating to separate wavelengths, which are detected using a 128-element diode array, the output of which is analyzed using a microprocessor. The spectrum is displayed on a small liquid crystal display screen and can be saved to a micro SD card for later analysis. Battery life (2 × AAA) is estimated to be 200 hours. The overall dimensions of the unit are 120 × 65 × 60 mm, and it weighs about 200 g. © The Author(s) 2016.

  1. Modular Manufacturing Simulator: Users Manual

    Science.gov (United States)

    1997-01-01

    The Modular Manufacturing Simulator (MMS) has been developed for the beginning user of computer simulations. Consequently, the MMS cannot model complex systems that require branching and convergence logic. Once a user becomes more proficient in computer simulation and wants to add more complexity, the user is encouraged to use one of the many available commercial simulation systems. The (MMS) is based on the SSE5 that was developed in the early 1990's by the University of Alabama in Huntsville (UAH). A recent survey by MSFC indicated that the simulator has been a major contributor to the economic impact of the MSFC technology transfer program. Many manufacturers have requested additional features for the SSE5. Consequently, the following features have been added to the MMS that are not available in the SSE5: runs under Windows, print option for both input parameters and output statistics, operator can be fixed at a station or assigned to a group of stations, operator movement based on time limit, part limit, or work-in-process (WIP) limit at next station. The movement options for a moveable operators are: go to station with largest WIP, rabbit chase where operator moves in circular sequence between stations, and push/pull where operator moves back and forth between stations. This user's manual contains the necessary information for installing the MMS on a PC, a description of the various MMS commands, and the solutions to a number of sample problems using the MMS. Also included in the beginning of this report is a brief discussion of technology transfer.

  2. Advanced manufacturing: Technology and international competitiveness

    Energy Technology Data Exchange (ETDEWEB)

    Tesar, A.

    1995-02-01

    Dramatic changes in the competitiveness of German and Japanese manufacturing have been most evident since 1988. All three countries are now facing similar challenges, and these challenges are clearly observed in human capital issues. Our comparison of human capital issues in German, Japanese, and US manufacturing leads us to the following key judgments: Manufacturing workforces are undergoing significant changes due to advanced manufacturing technologies. As companies are forced to develop and apply these technologies, the constituency of the manufacturing workforce (especially educational requirements, contingent labor, job content, and continuing knowledge development) is being dramatically and irreversibly altered. The new workforce requirements which result due to advanced manufacturing require a higher level of worker sophistication and responsibility.

  3. Cyber physical systems role in manufacturing technologies

    Science.gov (United States)

    Al-Ali, A. R.; Gupta, Ragini; Nabulsi, Ahmad Al

    2018-04-01

    Empowered by the recent development in single System-on-Chip, Internet of Things, and cloud computing technologies, cyber physical systems are evolving as a major controller during and post the manufacturing products process. In additional to their real physical space, cyber products nowadays have a virtual space. A product virtual space is a digital twin that is attached to it to enable manufacturers and their clients to better manufacture, monitor, maintain and operate it throughout its life time cycles, i.e. from the product manufacturing date, through operation and to the end of its lifespan. Each product is equipped with a tiny microcontroller that has a unique identification number, access code and WiFi conductivity to access it anytime and anywhere during its life cycle. This paper presents the cyber physical systems architecture and its role in manufacturing. Also, it highlights the role of Internet of Things and cloud computing in industrial manufacturing and factory automation.

  4. Research overview: Advanced Manufacturing in Switzerland

    OpenAIRE

    Schärer, Claudia

    2016-01-01

    SATW is convinced that industrial production methods will see fundamental changes over the coming years. Mastering new production technologies (advanced manufacturing) such as additive manufacturing and industry 4.0 will be vital to keep Swiss production at a competitive level. New additive manufacturing processes such as 3D printing offer revolutionary opportunities and have the potential to replace traditional production methods. Industry 4.0 has seen the definition of a new concept for...

  5. Manufacture and maintenance of laboratory equipment

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. K.; Whang, C. K.; Lee, J. H.; Youm, K. Y.; Hong, S. H.; Choi, H. Y.; An, C.; Park, I. W.; Kim, K. S.; Lee, W. J.; Yoon, K. B.; Kim, H. W.; Lee, I. B.; Lee, C. K.; Youm, J. H.; Oho, W. H.; Choi, B. K.; Jang, K. D.

    1996-12-01

    This report on the manufacture and maintenance of laboratory equipment contains working contents, scope and contents of a request working to the Machine Shop, also records the principal production design, manufacture contents and a relevant working drawing. The working content and scope of the Machine Shop is to support the successful and convenient performance of the R and D by manufacture and maintenance of all sorts of laboratory equipment. (author). 9 tabs., 12 figs.

  6. Characteristics and Manufacture of Spherical Smokeless Powders

    OpenAIRE

    Botelho, Fernanda Diniz; Galante, Erick Braga Ferrão; Mendes, Álvaro José Boareto

    2015-01-01

    ABSTRACT: Smokeless propellants have been studied and manufactured for many decades. They can exist in various physical forms and also can have different properties according to the use of each propellant. One important form of smokeless powders is the ball powder, which has spherical grains. The manufacture process of the ball powder has many advantages over the usual way to manufacture a smokeless powder. For example, unstable and even deteriorated nitrocellulose, after being stabilized aga...

  7. Exploring sustainable manufacturing principles and practices

    OpenAIRE

    Alayón, Claudia

    2016-01-01

    The manufacturing industry remains a critical force in the quest for global sustainability. An increasing number of companies are modifying their operations in favor of more sustainable practices. It is hugely important that manufacturers, irrespective of the subsector they belong to, or their organizational size, implement practices that reduce or eliminate negative environmental, social and economic impacts generated by their manufacturing operations. Consequently, scholars have called for ...

  8. Manufacturing of NAA laboratory clean room

    International Nuclear Information System (INIS)

    Suwoto; Hasibuan, Djaruddin

    2001-01-01

    The ''NAA laboratory clean room'' has been built in the Reactor Serba Guna G.A. Siwabessy building. The erection of ''AAN laboratory clean room'' doing by started of preparation of the ''manufacturing procedure'' refer to ''Design and manufacturing neutron activation analysis clean room laboratory''. Manufacturing process and erection doing refer to procedures makes. By providing of the ''AAN laboratory clean room'' can be cocluded that the research activity and the user sevises in P2TRR well meet to be done

  9. Cincinnati Big Area Additive Manufacturing (BAAM)

    Energy Technology Data Exchange (ETDEWEB)

    Duty, Chad E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Love, Lonnie J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-03-04

    Oak Ridge National Laboratory (ORNL) worked with Cincinnati Incorporated (CI) to demonstrate Big Area Additive Manufacturing which increases the speed of the additive manufacturing (AM) process by over 1000X, increases the size of parts by over 10X and shows a cost reduction of over 100X. ORNL worked with CI to transition the Big Area Additive Manufacturing (BAAM) technology from a proof-of-principle (TRL 2-3) demonstration to a prototype product stage (TRL 7-8).

  10. Participative knowledge management to empower manufacturing workers

    DEFF Research Database (Denmark)

    Campatelli, Gianni; Richter, Alexander; Stocker, Alexander

    2016-01-01

    skills. In this paper, the authors suggest a participative knowledge management approach to empower manufacturing workers. Starting from a comprehensive empirical analysis of the existing work practices in a manufacturing company, the authors have developed and validated a knowledge management system...... prototype. The prototype is aimed for training, problem solving, and facilitating the discovery, acquisition, and sharing of manufacturing knowledge. The conducted evaluation of the prototype indicates that workers' skills and level of work satisfaction will increase since the knowledge management system...

  11. Sustainability Assessment of Additive Manufacturing Processes

    OpenAIRE

    Lunetto, Vincenzo

    2017-01-01

    Additive Manufacturing (AM) processes were developed in the 1980s to reduce the time for the realization of prototypes. Nowadays, AM processes are considered as real manufacturing techniques suitable to build end-use products. As for any new technology, research efforts aiming to process planning and optimization within a sustainable development framework are needed. In particular, the application of the sustainable manufacturing principles requires the creation of products that use processes...

  12. Manufacture and maintenance of laboratory equipment

    International Nuclear Information System (INIS)

    Kim, Jong Kyun; Hwang, Chang Kyu; Hwang, Bong Ha; Lee, Jong Wha; Yeom, Ki Eon; Park, Myung Ku; Hong, Soon Hyeon; Choi, Ho Young; An, Dae Kyu; An, Choon; Park, In Won; Kim, Kyeong Sik; Lee, In Bae; Yeom, Jeong Heon; Lee, Chul Ku; Sin, Keon Ju; Oh, Wan Ho; Choi, Byung Kwon; Chang, Kyeong Duk; Lee, Young Soon

    1995-12-01

    This report on the manufacture and maintenance of laboratory equipment contains working contents, scope and contents of a request working to the Machine Shop, also records the principal production design, manufacture contents and a relevant working drawing. The working content and scope of the Machine Shop is to support the successful and convenient performance of the Research and development by manufacture and maintenance of all sorts of laboratory equipment. 12 tabs., 5 figs. (Author) .new

  13. Additive Manufacturing: Ensuring Quality for Spacecraft Applications

    Science.gov (United States)

    Swanson, Theodore; Stephenson, Timothy

    2014-01-01

    Reliable manufacturing requires that material properties and fabrication processes be well defined in order to insure that the manufactured parts meet specified requirements. While this issue is now relatively straightforward for traditional processes such as subtractive manufacturing and injection molding, this capability is still evolving for AM products. Hence, one of the principal challenges within AM is in qualifying and verifying source material properties and process control. This issue is particularly critical for applications in harsh environments and demanding applications, such as spacecraft.

  14. Building a Competitive Edge with Additive Manufacturing

    Science.gov (United States)

    2013-02-14

    Technology News, Volume 19, No. 7 (April 30, 2012). 39 Stephanie S. Shipp et al., Emerging Global Trends in Advanced Manufacturing, IDA Paper P-4603...December 2012. 21 41 Stephanie S. Shipp et al., Emerging Global Trends in Advanced Manufacturing, IDA Paper P-4603 (Alexandria, VA: Institute... Shipp , Stephanie, et al., Emerging Global Trends in Advanced Manufacturing, IDA Paper P- 4603 (Alexandria, VA: Institute for Defense Analysis, March

  15. Integrated and Intelligent Manufacturing: Perspectives and Enablers

    Directory of Open Access Journals (Sweden)

    Yubao Chen

    2017-10-01

    Full Text Available With ever-increasing market competition and advances in technology, more and more countries are prioritizing advanced manufacturing technology as their top priority for economic growth. Germany announced the Industry 4.0 strategy in 2013. The US government launched the Advanced Manufacturing Partnership (AMP in 2011 and the National Network for Manufacturing Innovation (NNMI in 2014. Most recently, the Manufacturing USA initiative was officially rolled out to further “leverage existing resources... to nurture manufacturing innovation and accelerate commercialization” by fostering close collaboration between industry, academia, and government partners. In 2015, the Chinese government officially published a 10-year plan and roadmap toward manufacturing: Made in China 2025. In all these national initiatives, the core technology development and implementation is in the area of advanced manufacturing systems. A new manufacturing paradigm is emerging, which can be characterized by two unique features: integrated manufacturing and intelligent manufacturing. This trend is in line with the progress of industrial revolutions, in which higher efficiency in production systems is being continuously pursued. To this end, 10 major technologies can be identified for the new manufacturing paradigm. This paper describes the rationales and needs for integrated and intelligent manufacturing (i2M systems. Related technologies from different fields are also described. In particular, key technological enablers, such as the Internet of Things and Services (IoTS, cyber-physical systems (CPSs, and cloud computing are discussed. Challenges are addressed with applications that are based on commercially available platforms such as General Electric (GE’s Predix and PTC’s ThingWorx.

  16. COMPONENTS PROVISION MANAGEMENT FOR MACHINE BUILDING MANUFACTURER

    Directory of Open Access Journals (Sweden)

    Ekaterina P. Bochkareva

    2014-01-01

    Full Text Available In the paper is given an approach to themanagement of components provision formachine building manufacturer based uponinternational standards and best practicesof leading international companies. Thecomplex expertise methods are used forthe development of the proposed machinebuilding manufacturer suppliers’ operational management method. At a strategic level is proposed a tool for planning the suppliers’portfolio and a machine building manufacturer supplier development methodology.

  17. Inside-Out Manufacturing of Composite Structures

    Data.gov (United States)

    National Aeronautics and Space Administration — Tooling for the manufacture of large structures from composite materials often costs much more than individual parts, rendering the processes unattractive for...

  18. Solid State Lighting OLED Manufacturing Roundtable Summary

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2010-03-31

    Summary of a meeting of OLED experts to develop proposed priority tasks for the Manufacturing R&D initiative, including task descriptions, discussion points, recommendations, and presentation highlights.

  19. Solid State Lighting LED Manufacturing Roundtable Summary

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2010-03-31

    Summary of a meeting of LED experts to develop proposed priority tasks for the Manufacturing R&D initiative, including task descriptions, discussion points, recommendations, and presentation highlights.

  20. Advanced Manufacturing Technologies (AMT): Composites Integrated Modeling

    Data.gov (United States)

    National Aeronautics and Space Administration — The Composites Integrated Modeling (CIM) Element developed low cost, lightweight, and efficient composite structures, materials and manufacturing technologies with...

  1. News: Good chemical manufacturing process criteria

    Science.gov (United States)

    This news column covers topics relating to manufacturing criteria, machine to machine technology, novel process windows, green chemistry indices, business resilience, immobilized enzymes, and Bt crops.

  2. Laser Additive Manufacturing of Gas Permeable Structures

    Science.gov (United States)

    Klahn, C.; Bechmann, F.; Hofmann, S.; Dinkel, M.; Emmelmann, C.

    Laser additive manufacturing offers a variety of new design possibilities. In mold making laser additive manufactured inserts with conformal cooling channels are already state of the art. Pneumatic ejectors for injection molds are a new application for laser additive manufacturing. The pneumatic ejectors require a durable gas permeable material. This material is produced by placing the scan vectors for the laser additive manufacturing process in a defined pattern. Trials with different plastics proofed the function and reliability of the pneumatic ejector concept in the injection molding cycle.

  3. Rapid Response Manufacturing (RRM). Final CRADA report

    Energy Technology Data Exchange (ETDEWEB)

    Cain, W.D. [Lockheed Martin Energy Systems, Inc., Oak Ridge, TN (United States); Waddell, W.L. [National Centers for Manufacturing Sciences, Ann Arbor, MI (United States)

    1997-08-28

    A major accomplishment of the Rapid Response Manufacturing (RRM) project was the development of a broad-based generic framework for automating and integrating the design-to-manufacturing activities associated with machined part products. Key components of the framework are a manufacturing model that integrates product and process data in a consistent, minimally redundant manner, an advanced computer-aided engineering working environment, knowledge-based software systems for design, process planning, and manufacturing and new production technologies for making products directly from design application software.

  4. Semiconductors integrated circuit design for manufacturability

    CERN Document Server

    Balasinki, Artur

    2011-01-01

    Because of the continuous evolution of integrated circuit manufacturing (ICM) and design for manufacturability (DfM), most books on the subject are obsolete before they even go to press. That's why the field requires a reference that takes the focus off of numbers and concentrates more on larger economic concepts than on technical details. Semiconductors: Integrated Circuit Design for Manufacturability covers the gradual evolution of integrated circuit design (ICD) as a basis to propose strategies for improving return-on-investment (ROI) for ICD in manufacturing. Where most books put the spotl

  5. In-Space Manufacturing Project (prior to FY15: Additive Manufacturing Technology Development)

    Data.gov (United States)

    National Aeronautics and Space Administration — The In-Space Manufacturing (ISM) project is responsible for developing the manufacturing capabilities that will provide on-demand, sustainable operations during NASA...

  6. Subcontracting in electronics : from contract manufacturers to providers of electronic manufacturing services (EMS)

    OpenAIRE

    Liemt van, Gijsbert

    2007-01-01

    Discusses how the top contract manufacturers in the electronics industry try to become providers of electronic manufacturing services by deepening and broadening the rage of services that they offer and by diversifying into markets other than computing and telecommunications.

  7. Advanced Manufacturing Technologies (AMT): Additive Manufactured Hot Fire Planning and Testing in GRC Cell 32 Project

    Science.gov (United States)

    Fikes, John C.

    2014-01-01

    The objective of this project is to hot fire test an additively manufactured thrust chamber assembly TCA (injector and thrust chamber). GRC will install the additively manufactured Inconel 625 injector, two additively manufactured (SLM) water cooled Cu-Cr thrust chamber barrels and one additively manufactured (SLM) water cooled Cu-Cr thrust chamber nozzle on the test stand in Cell 32 and perform hot fire testing of the integrated TCA.

  8. [The content of mineral elements in Camellia olei fera ovary at pollination and fertilization stages determined by auto discrete analyzers and atomic absorption spectrophotometer].

    Science.gov (United States)

    Zou, Feng; Yuan, De-Yi; Gao, Chao; Liao, Ting; Chen, Wen-Tao; Han, Zhi-Qiang; Zhang, Lin

    2014-04-01

    In order to elucidate the nutrition of Camellia olei fera at pollination and fertilization stages, the contents of mineral elements were determined by auto discrete analyzers and atomic absorption spectrophotometer, and the change in the contents of mineral elements was studied and analysed under the condition of self- and cross-pollination. The results are showed that nine kinds of mineral elements contents were of "S" or "W" type curve changes at the pollination and fertilization stages of Camellia olei fera. N, K, Zn, Cu, Ca, Mn element content changes showed "S" curve under the self- and out-crossing, the content of N reaching the highest was 3.445 8 mg x g(-1) in self-pollination of 20 d; K content reaching the highest at the cross-pollination 20 d was 6.275 5 mg x g(-1); Zn content in self-pollination of 10 d reaching the highest was 0.070 5 mg x g(-1); Cu content in the cross-pollination of 5 d up to the highest was 0.061 0 mg x g(-1); Ca content in the cross-pollination of 15 d up to the highest was 3.714 5 mg x g(-1); the content of Mn reaching the highest in self-pollination 30 d was 2. 161 5 mg x g(-1). Fe, P, Mg element content changes was of "S" type curve in selfing and was of "W" type curve in outcrossing, Fe content in the self-pollination 10 d up to the highest was 0.453 0 mg x g(-1); P content in self-pollination of 20 d reaching the highest was 6.731 8 mg x g(-1); the content of Mg up to the highest in self-pollination 25 d was 2.724 0 mg x g(-1). The results can be used as a reference for spraying foliar fertilizer, and improving seed setting rate and yield in Camellia olei fera.

  9. Manufacturing microporous membrane by polymerisation

    International Nuclear Information System (INIS)

    Tanny, G.B.

    1984-01-01

    The starting materials for the practice of the present invention are (1) one or more organic monomers or oligomers which upon irradiation very rapidly undergo a polymerization reaction to form a solid polymer; and (2) a liquid vehicle in which the one or more organic monomers or oligomers are soluble but in which the polymer formed is insoluble. For the manufacture of microporous membrane in accordance with the invention the monomers or oligomers are dissolved in the liquid vehicle, the resulting solution is formed into a thin layer, and the thin layer of the solution is then irradiated as with ultraviolet or electron beam radiation whereupon the rapid polymerization reaction immediately ensues and the polymer formed immediately segregates from the vehicle thereby resulting in microporous membrane from which the vehicle can be removed as by evaporation or washing. Because the radiation-induced polymerization reaction and the segregation of the polymer formed are so rapid, the membrane formed has cells and communications therebetween of very small dimensions thereby providing the microporous structure. Where ultra-violet radiation is used the solution also includes a photo-initiator. (author)

  10. Optimization of space manufacturing systems

    Science.gov (United States)

    Akin, D. L.

    1979-01-01

    Four separate analyses are detailed: transportation to low earth orbit, orbit-to-orbit optimization, parametric analysis of SPS logistics based on earth and lunar source locations, and an overall program option optimization implemented with linear programming. It is found that smaller vehicles are favored for earth launch, with the current Space Shuttle being right at optimum payload size. Fully reusable launch vehicles represent a savings of 50% over the Space Shuttle; increased reliability with less maintenance could further double the savings. An optimization of orbit-to-orbit propulsion systems using lunar oxygen for propellants shows that ion propulsion is preferable by a 3:1 cost margin over a mass driver reaction engine at optimum values; however, ion engines cannot yet operate in the lower exhaust velocity range where the optimum lies, and total program costs between the two systems are ambiguous. Heavier payloads favor the use of a MDRE. A parametric model of a space manufacturing facility is proposed, and used to analyze recurring costs, total costs, and net present value discounted cash flows. Parameters studied include productivity, effects of discounting, materials source tradeoffs, economic viability of closed-cycle habitats, and effects of varying degrees of nonterrestrial SPS materials needed from earth. Finally, candidate optimal scenarios are chosen, and implemented in a linear program with external constraints in order to arrive at an optimum blend of SPS production strategies in order to maximize returns.

  11. Manufacturing and testing VLPC hybrids

    Science.gov (United States)

    Adkins, L. R.; Ingram, C. M.; Anderson, E. J.

    1998-11-01

    To insure that the manufacture of VLPC devices is a reliable, cost-effective technology, hybrid assembly procedures and testing methods suitable for large scale production have been developed. This technology has been developed under a contract from Fermilab as part of the D-Zero upgrade program. Each assembled hybrid consists of a VLPC chip mounted on an AlN substrate. The VLPC chip is provided with bonding pads (one connected to each pixel) which are wire bonded to gold traces on the substrate. The VLPC/AlN hybrids are mated in a vacuum sealer using solder preforms and a specially designed carbon boat. After mating, the VLPC pads are bonded to the substrate with an automatic wire bonder. Using this equipment we have achieved a thickness tolerance of ±0.0007 inches and a production rate of 100 parts per hour. After assembly the VLPCs are tested for optical response at an operating temperature of 7K. The parts are tested in a custom designed continuous-flow dewar with a capacity 15 hybrids, and one Lake Shore DT470-SD-11 calibrated temperature sensor mounted to an AlN substrate. Our facility includes five of these dewars with an ultimate test capacity of 75 parts per day. During the course of the Dzero program we have assembled more than 4,000 VLPC hybrids and have tested more than 2,500 with a high yield.

  12. CORRECTIVE ACTION IN CAR MANUFACTURING

    Directory of Open Access Journals (Sweden)

    H. Rohne

    2012-01-01

    Full Text Available

    ENGLISH ABSTRACT: In this paper the important .issues involved in successfully implementing corrective action systems in quality management are discussed. The work is based on experience in implementing and operating such a system in an automotive manufacturing enterprise in South Africa. The core of a corrective action system is good documentation, supported by a computerised information system. Secondly, a systematic problem solving methodology is essential to resolve the quality related problems identified by the system. In the following paragraphs the general corrective action process is discussed and the elements of a corrective action system are identified, followed by a more detailed discussion of each element. Finally specific results from the application are discussed.

    AFRIKAANSE OPSOMMING: Belangrike oorwegings by die suksesvolle implementering van korrektiewe aksie stelsels in gehaltebestuur word in hierdie artikel bespreek. Die werk is gebaseer op ondervinding in die implementering en bedryf van so 'n stelsel by 'n motorvervaardiger in Suid Afrika. Die kern van 'n korrektiewe aksie stelsel is goeie dokumentering, gesteun deur 'n gerekenariseerde inligtingstelsel. Tweedens is 'n sistematiese probleemoplossings rnetodologie nodig om die gehalte verwante probleme wat die stelsel identifiseer aan te spreek. In die volgende paragrawe word die algemene korrektiewe aksie proses bespreek en die elemente van die korrektiewe aksie stelsel geidentifiseer. Elke element word dan in meer besonderhede bespreek. Ten slotte word spesifieke resultate van die toepassing kortliks behandel.

  13. Dynamics of ultrasonic additive manufacturing.

    Science.gov (United States)

    Hehr, Adam; Dapino, Marcelo J

    2017-01-01

    Ultrasonic additive manufacturing (UAM) is a solid-state technology for joining similar and dissimilar metal foils near room temperature by scrubbing them together with ultrasonic vibrations under pressure. Structural dynamics of the welding assembly and work piece influence how energy is transferred during the process and ultimately, part quality. To understand the effect of structural dynamics during UAM, a linear time-invariant model is proposed to relate the inputs of shear force and electric current to resultant welder velocity and voltage. Measured frequency response and operating performance of the welder under no load is used to identify model parameters. Using this model and in-situ measurements, shear force and welder efficiency are estimated to be near 2000N and 80% when welding Al 6061-H18 weld foil, respectively. Shear force and welder efficiency have never been estimated before in UAM. The influence of processing conditions, i.e., welder amplitude, normal force, and weld speed, on shear force and welder efficiency are investigated. Welder velocity was found to strongly influence the shear force magnitude and efficiency while normal force and weld speed showed little to no influence. The proposed model is used to describe high frequency harmonic content in the velocity response of the welder during welding operations and coupling of the UAM build with the welder. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Manufacturing Capacity Utilization and Industrial Development in ...

    African Journals Online (AJOL)

    This paper investigates the impact of manufacturing capacity utilization on industrial development in Nigeria during the period of 1976 – 2005. Manufacturing capacity utilization, value added and employment generation were regressed on index of industrial productivity (which served as the proxy for industrial development) ...

  15. Recent development of cellular manufacturing systems

    Indian Academy of Sciences (India)

    Cellular manufacturing system has been proved a vital approach for batch and job shop production systems. Group technology has been an essential tool for developing a cellular manufacturing system. The paper aims to discuss various cell formation techniques and highlights the significant research work done in past ...

  16. Dynamic cellular manufacturing system design considering ...

    Indian Academy of Sciences (India)

    Kamal Deep

    annealing based genetic algorithm (SAGA) is applied to optimize the number of machines in different manufactur- ing cells in a manufacturing system producing multiple product mix. The main constraints are the production capacity and the maximum cell size. 2. Literature review. Over the last three decades, a large number ...

  17. Manufacturing Enterprise in Asia | IDRC - International Development ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    2012-08-23

    Aug 23, 2012 ... Issues relating to the size of manufacturing firms are central to the discussion of development strategies. This book offers an interpretation of growth trajectories in the size-structure of enterprises in the manufacturing sector of selected Asian economies.

  18. Quality and workflow integration in flexible manufacturing

    NARCIS (Netherlands)

    ten Dam, Dennis

    2012-01-01

    In recognising the relevance of production networks and flexible manufacturing, CNC Worknet aims to be a company that approaches the new era of flexible manufacturing by developing a novel business model that combines the technologies of e-Business with production networks. This business model is

  19. Additive Manufacturing of Biomaterials, Tissues, and Organs

    NARCIS (Netherlands)

    Zadpoor, Amir A; Malda, Jos

    The introduction of additive manufacturing (AM), often referred to as three-dimensional (3D) printing, has initiated what some believe to be a manufacturing revolution, and has expedited the development of the field of biofabrication. Moreover, recent advances in AM have facilitated further

  20. Additive Manufacturing of Biomaterials, Tissues, and Organs

    NARCIS (Netherlands)

    Zadpoor, Amir A; Malda, Jos

    2017-01-01

    The introduction of additive manufacturing (AM), often referred to as three-dimensional (3D) printing, has initiated what some believe to be a manufacturing revolution, and has expedited the development of the field of biofabrication. Moreover, recent advances in AM have facilitated further

  1. Coordinating knowledge transfer within manufacturing networks

    DEFF Research Database (Denmark)

    Yang, Cheng; Johansen, John; Boer, Harry

    2008-01-01

    Along with increasing globalization, the management of international manufacturing networks is becoming increasingly important for industrial companies. This paper mainly focuses on the coordination of knowledge transfer within manufacturing networks. In this context, we propose the time...... these questions are discussed, based on which a frame of thought is proposed that managers can use in their quest for network competitiveness....

  2. Manufacturing development of DC-10 advanced rudder

    Science.gov (United States)

    Cominsky, A.

    1979-01-01

    The design, manufacture, and ground test activities during development of production methods for an advanced composite rudder for the DC-10 transport aircraft are described. The advanced composite aft rudder is satisfactory for airline service and a cost saving in a full production manufacturing mode is anticipated.

  3. Manufacturing processes 2 grinding, honing, lapping

    CERN Document Server

    Klocke, Fritz

    2009-01-01

    Presents a view of the most common machining and non-machining manufacturing processes. This volume describes the characteristics of abrasive tools, their design and manufacturing, followed by the fundamentals of grinding fluids. It also discusses grinding of different materials (steel, cast iron, hard and brittle materials, nickel and titanium).

  4. Challenges in Teaching Modern Manufacturing Technologies

    Science.gov (United States)

    Ngaile, Gracious; Wang, Jyhwen; Gau, Jenn-Terng

    2015-01-01

    Teaching of manufacturing courses for undergraduate engineering students has become a challenge due to industrial globalisation coupled with influx of new innovations, technologies, customer-driven products. This paper discusses development of a modern manufacturing course taught concurrently in three institutions where students collaborate in…

  5. Advanced Manufacturing Office Clean Water Processing Technologies

    Energy Technology Data Exchange (ETDEWEB)

    None

    2018-03-01

    The DOE Office of Energy Efficiency and Renewable Energy (EERE)’s Advanced Manufacturing Office partners with industry, small business, universities, and other stakeholders to identify and invest in emerging technologies with the potential to create high-quality domestic manufacturing jobs and enhance the global competitiveness of the United States.

  6. Manufacturing Capacity Utilization and Industrial Development in ...

    African Journals Online (AJOL)

    FIRST LADY

    utilization in the late 1970s was as high as 78.70 percent and nosedived to as low as 43.80 percent in the 1980s. Between ... through a regime of high inflation rate which makes domestic manufacturers and domestic market ... However, inflation and loans and advances to manufacturing were found to have negative effect.

  7. Photonic crystal scintillators and methods of manufacture

    Science.gov (United States)

    Torres, Ricardo D.; Sexton, Lindsay T.; Fuentes, Roderick E.; Cortes-Concepcion, Jose

    2015-08-11

    Photonic crystal scintillators and their methods of manufacture are provided. Exemplary methods of manufacture include using a highly-ordered porous anodic alumina membrane as a pattern transfer mask for either the etching of underlying material or for the deposition of additional material onto the surface of a scintillator. Exemplary detectors utilizing such photonic crystal scintillators are also provided.

  8. Additive Manufacturing for Low Volume Bearings

    Energy Technology Data Exchange (ETDEWEB)

    Tate, John G. [Schaeffler Group USA, Spartanburg, SC (United States); Richardson, Bradley S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Love, Lonnie J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-09-01

    ORNL worked with the Schaeffler Group USA to explore additive manufacturing techniques that might be appropriate for prototyping of bearing cages. Multiple additive manufacturing techniques were investigated, including e-beam, binder jet and multiple laser based processes. The binder jet process worked best for the thin, detailed cages printed.

  9. 75 FR 71417 - Manufacturing Council Membership

    Science.gov (United States)

    2010-11-23

    ....S. manufacturing industry in terms of industry sectors, geographic locations, demographics, and company size, particularly seeking the representation of small- and medium-sized enterprises. Based on the diversity of the manufacturing industry currently represented on the Council for this charter term, the...

  10. Recent development of cellular manufacturing systems

    Indian Academy of Sciences (India)

    context of cellular manufacturing is primarily as an aid in identifying the part families to which production cells should be dedicated. Further analysis is required ... A number of researchers or investigators have used different types of similarity and dissimilarity coefficients for determining part families. In cellular manufacturing ...

  11. 75 FR 36421 - Draft Guidance for Industry on Chemistry, Manufacturing, and Controls Postapproval Manufacturing...

    Science.gov (United States)

    2010-06-25

    ... HUMAN SERVICES Food and Drug Administration Draft Guidance for Industry on Chemistry, Manufacturing, and... reported in annual reports. Specifically, the draft guidance describes chemistry, manufacturing, and... the many advances in quality management practices in manufacturing and to enable the agency to more...

  12. Agile manufacturing from a statistical perspective

    Energy Technology Data Exchange (ETDEWEB)

    Easterling, R.G. [Sandia National Labs., Albuquerque, NM (United States). New Initiatives Dept.

    1995-10-01

    The objective of agile manufacturing is to provide the ability to quickly realize high-quality, highly-customized, in-demand products at a cost commensurate with mass production. More broadly, agility in manufacturing, or any other endeavor, is defined as change-proficiency; the ability to thrive in an environment of unpredictable change. This report discusses the general direction of the agile manufacturing initiative, including research programs at the National Institute of Standards and Technology (NIST), the Department of Energy, and other government agencies, but focuses on agile manufacturing from a statistical perspective. The role of statistics can be important because agile manufacturing requires the collection and communication of process characterization and capability information, much of which will be data-based. The statistical community should initiate collaborative work in this important area.

  13. Lean Application to Manufacturing Ramp-Up

    DEFF Research Database (Denmark)

    Christensen, Irene; Rymaszewska, Anna

    2016-01-01

    product development process, that is, the ramp-up process, is a critical, early enabler of lean manufacturing. The manufacturing strategy literature conceptualizes a state of “leanness in operations,” which can consolidate both the concepts of lean and manufacturing ramp-up, providing a dual perspective......This article provides a theoretical overview of the concepts of lean and manufacturing ramp-up in an attempt to conceptualize the strategic areas in which lean philosophy and principles can be applied for continuous improvements. The application of lean principles during the final stage of a new....... Abstracting from the extant literature, the authors considered the competitiveness of manufacturing companies from two principal perspectives: the leanness of the ramp-up process and the new-value creation of quality managers. While much of the literature fails to acknowledge that the roots of lean actually...

  14. Sustainable manufacturing challenges, solutions and implementation perspectives

    CERN Document Server

    Seliger, Günther; Bonvoisin, Jérémy

    2017-01-01

    Sustainability imposes an unprecedented challenge on society and has become the driving force of an urgent search for innovative solutions in all branches of economy. Manufacturing plays a key role in many areas of human living, and it is both part of the problem and of the solution. This book offers an overview of the broad field of research on sustainability in manufacturing with a particular focus on manufacturing technology and management. It summarizes the current challenges, describes best in class methods for development of sustainable manufacturing solutions and offers implementation perspectives. This volume covers areas of research such as production processes, product development, business model and corporate development, macro economy and education. The target audience primarily comprises research experts and practitioners in the field of manufacturing, but the book may also be beneficial for graduate students. .

  15. Fundamentals of semiconductor manufacturing and process control

    CERN Document Server

    May, Gary S

    2006-01-01

    A practical guide to semiconductor manufacturing from process control to yield modeling and experimental design Fundamentals of Semiconductor Manufacturing and Process Control covers all issues involved in manufacturing microelectronic devices and circuits, including fabrication sequences, process control, experimental design, process modeling, yield modeling, and CIM/CAM systems. Readers are introduced to both the theory and practice of all basic manufacturing concepts. Following an overview of manufacturing and technology, the text explores process monitoring methods, including those that focus on product wafers and those that focus on the equipment used to produce wafers. Next, the text sets forth some fundamentals of statistics and yield modeling, which set the foundation for a detailed discussion of how statistical process control is used to analyze quality and improve yields. The discussion of statistical experimental design offers readers a powerful approach for systematically varying controllable p...

  16. Multi-agent for manufacturing systems optimization

    Science.gov (United States)

    Ciortea, E. M.; Tulbure, A.; Huţanu, C.-tin

    2016-08-01

    The paper is meant to be a dynamic approach to optimize manufacturing systems based on multi-agent systems. Multi-agent systems are semiautonomous decision makers and cooperate to optimize the manufacturing process. Increasing production the capacity is achieved by developing, implementing efficient and effective systems from control based on current manufacturing process. The model multi-agent proposed in this paper is based on communication between agents who, based on their mechanisms drive to autonomous decision making. Methods based on multi-agent programming are applied between flexible manufacturing processes and cooperation with agents. Based on multi-agent technology and architecture of intelligent manufacturing can lead to development of strategies for control and optimization of scheduled production resulting from the simulation.

  17. The Economics of Big Area Addtiive Manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Post, Brian [Oak Ridge National Laboratory (ORNL); Lloyd, Peter D [ORNL; Lindahl, John [Oak Ridge National Laboratory (ORNL); Lind, Randall F [ORNL; Love, Lonnie J [ORNL; Kunc, Vlastimil [ORNL

    2016-01-01

    Case studies on the economics of Additive Manufacturing (AM) suggest that processing time is the dominant cost in manufacturing. Most additive processes have similar performance metrics: small part sizes, low production rates and expensive feedstocks. Big Area Additive Manufacturing is based on transitioning polymer extrusion technology from a wire to a pellet feedstock. Utilizing pellets significantly increases deposition speed and lowers material cost by utilizing low cost injection molding feedstock. The use of carbon fiber reinforced polymers eliminates the need for a heated chamber, significantly reducing machine power requirements and size constraints. We hypothesize that the increase in productivity coupled with decrease in feedstock and energy costs will enable AM to become more competitive with conventional manufacturing processes for many applications. As a test case, we compare the cost of using traditional fused deposition modeling (FDM) with BAAM for additively manufacturing composite tooling.

  18. Manufacturing fuel-switching capability, 1988

    Energy Technology Data Exchange (ETDEWEB)

    1991-09-01

    Historically, about one-third of all energy consumed in the United States has been used by manufacturers. About one-quarter of manufacturing energy is used as feedstocks and raw material inputs that are converted into nonenergy products; the remainder is used for its energy content. During 1988, the most recent year for which data are available, manufacturers consumed 15.5 quadrillion British thermal units (Btu) of energy to produce heat and power and to generate electricity. The manufacturing sector also has widespread capabilities to switch from one fuel to another for either economic or emergency reasons. There are numerous ways to define fuel switching. For the purposes of the Manufacturing Energy Consumption Survey (MECS), fuel switching is defined as the capability to substitute one energy source for another within 30 days with no significant modifications to the fuel-consuming equipment, while keeping production constant. Fuel-switching capability allows manufacturers substantial flexibility in choosing their mix of energy sources. The consumption of a given energy source can be maximized if all possible switching into that energy source takes place. The estimates in this report are based on data collected on the 1988 Manufacturing Energy Consumption Survey (MECS), Forms 846 (A through C). The EIA conducts this national sample survey of manufacturing energy consumption on a triennial basis. The MECS is the only comprehensive source of national-level data on energy-related information for the manufacturing industries. The MECS was first conducted in 1986 to collect data for 1985. This report presents information on the fuel-switching capabilities of manufacturers in 1988. This report is the second of a series based on the 1988 MECS. 8 figs., 31 tabs.

  19. Manufacturing fuel-switching capability, 1988

    International Nuclear Information System (INIS)

    1991-09-01

    Historically, about one-third of all energy consumed in the United States has been used by manufacturers. About one-quarter of manufacturing energy is used as feedstocks and raw material inputs that are converted into nonenergy products; the remainder is used for its energy content. During 1988, the most recent year for which data are available, manufacturers consumed 15.5 quadrillion British thermal units (Btu) of energy to produce heat and power and to generate electricity. The manufacturing sector also has widespread capabilities to switch from one fuel to another for either economic or emergency reasons. There are numerous ways to define fuel switching. For the purposes of the Manufacturing Energy Consumption Survey (MECS), fuel switching is defined as the capability to substitute one energy source for another within 30 days with no significant modifications to the fuel-consuming equipment, while keeping production constant. Fuel-switching capability allows manufacturers substantial flexibility in choosing their mix of energy sources. The consumption of a given energy source can be maximized if all possible switching into that energy source takes place. The estimates in this report are based on data collected on the 1988 Manufacturing Energy Consumption Survey (MECS), Forms 846 (A through C). The EIA conducts this national sample survey of manufacturing energy consumption on a triennial basis. The MECS is the only comprehensive source of national-level data on energy-related information for the manufacturing industries. The MECS was first conducted in 1986 to collect data for 1985. This report presents information on the fuel-switching capabilities of manufacturers in 1988. This report is the second of a series based on the 1988 MECS. 8 figs., 31 tabs

  20. Design of the detector to observe the energetic charged particles: a part of the solar X-ray spectrophotometer ChemiX onboard Interhelio-Probe mission

    Science.gov (United States)

    Dudnik, Oleksiy; Sylwester, Janusz; Kowalinski, Miroslaw; Bakala, Jaroslaw; Siarkowski, Marek; Evgen Kurbatov, mgr..

    2016-07-01

    -layer detector stack: first two layers consist of silicon detectors; the third one is based on the p-terphenyl scintillation detector coupled with pixelated silicon photomultiplier. Coincidence logic allows collecting systematic data on particle variety and their energy with 1 and/or 10 s time resolutions. Digital processing unit is constructed based on FPGA Actel ProAsic M1A3PE1500, and contains each event processing logic, forms telemetry data and housekeeping frames, communicates with ChemiX digital processing unit and executes received telecommands. In order to increase the reliability and time resource of the BPM its digital processing unit and secondary power supply unit has backup sets. Switching between backup sets is commanded by externally orders. The BPM is capable to sort out in situ abundances of individual particle constituents from electrons up to oxygen nuclei. 1. O.V.Dudnik, E.V.Kurbatov, V.O.Tarasov, L.A.Andryushenko, I.L.Zajtsevsky, J.Sylwester, J.Bąkala, M.Kowaliński. Background particle detector for the solar X-ray photometer ChemiX of space mission "Interhelioprobe": an adjustment of breadboard model modules (in Russian) / ISSN 1561-8889: Kosmichna Nauka I Tekhnologiya, 2015, Vol.21, No.2, P.3-14. 2. O.V.Dudnik, E.V.Kurbatov, J.Sylwester, M.Siarkowski, P.Podgórski, M.Kowaliński. Background Particle Monitor - a part of the solar X-ray spectrophotometer ChemiX: principles of the operation and construction / in: Abstracts of 15th Ukrainian conference on space research, Odesa, Ukraine, August 24-28, 2015, P.80, doi:10.13140/RG.2.1.2284.2649. 3. O.V.Dudnik, E.V.Kurbatov, M.Kowaliński, M.Siarkowski, P.Podgórski, J.Sylwester. Operational features of Background Particle Monitor, a vital part of the solar X-ray spectrophotometer ChemiX / in: Abstract book of the Conference "Progress on EUV&X-ray spectroscopy and imaging II", Wroclaw, Poland, November 17 19, 2015, P.9, doi:10.13140/RG.2.1.1184.3604.

  1. Integrated lunar materials manufacturing process

    Science.gov (United States)

    Gibson, Michael A. (Inventor); Knudsen, Christian W. (Inventor)

    1990-01-01

    A manufacturing plant and process for production of oxygen on the moon uses lunar minerals as feed and a minimum of earth-imported, process materials. Lunar feed stocks are hydrogen-reducible minerals, ilmenite and lunar agglutinates occurring in numerous, explored locations mixed with other minerals in the pulverized surface layer of lunar soil known as regolith. Ilmenite (FeTiO.sub.3) and agglutinates contain ferrous (Fe.sup.+2) iron reducible by hydrogen to yield H.sub.2 O and metallic Fe at about 700.degree.-1,200.degree. C. The H.sub.2 O is electrolyzed in gas phase to yield H.sub.2 for recycle and O.sub.2 for storage and use. Hydrogen losses to lunar vacuum are minimized, with no net hydrogen (or any other earth-derived reagent) consumption except for small leaks. Feed minerals are surface-mined by front shovels and transported in trucks to the processing area. The machines are manned or robotic. Ilmenite and agglutinates occur mixed with silicate minerals which are not hydrogen-reducible at 700.degree.-1,200.degree. C. and consequently are separated and concentrated before feeding to the oxygen generation process. Solids rejected from the separation step and reduced solids from the oxygen process are returned to the mine area. The plant is powered by nuclear or solar power generators. Vapor-phase water electrolysis, a staged, countercurrent, fluidized bed reduction reactor and a radio-frequency-driven ceramic gas heater are used to improve thermal efficiency.

  2. Technological assessment of local manufacturers for wind turbine blade manufacturing in Pakistan

    Science.gov (United States)

    Mahmood, Khurram; Haroon, General

    2012-11-01

    Composite materials manufacturing industry is one of the world's hi-tech industry. Manufacturing of wind turbine blades is one of the specialized fields requiring high degree of precision and composite manufacturing techniques. This paper identifies the industries specializing in the composite manufacturing and is able to manufacture wind turbines blades in Pakistan. In the second phase, their technology readiness level is determined, based on some factors and then a readiness level are assigned to them. The assigned technology readiness level will depict the absorptive capacity of each manufacturing unit and its capability to take on such projects. The individual readiness level of manufacturing unit will then be used to establish combined technology readiness level of Pakistan particularly for wind turbine blades manufacturing. The composite manufacturing industry provides many spin offs and a diverse range of products can be manufactured using this facility. This research will be helpful to categorize the strong points and flaws of local industry for the gap analysis. It can also be used as a prerequisite study before the evaluation of technologies and specialties to improve the industry of the country for the most favorable results. This will form a basic data base which can be used for the decision making related to transfer of technology, training of local skilled workers and general up-gradation of the local manufacturing units.

  3. EXPLORING CRITICAL FACTORS FOR SUCCESSFULLY IMPLEMENTING LEAN MANUFACTURING AT MANUFACTURING COMPANIES IN VIETNAM

    Directory of Open Access Journals (Sweden)

    Nguyen Thi Duc Nguyen

    2017-06-01

    Full Text Available This study focuses on exploring the factors that influence the success of the Lean Manufacturing implementation at manufacturing companies in Vietnam. The mix-research methods are applied, including: reviewing previous studies, in-depth interviewing with experts in manufacturing field and case study-researching at two typical manufacturing companies in Vietnam. The results show that the significant issues, such as: leadership, communication at work, firm's financial capacity, employee's skills and expertise, organizational culture, customer and supplier management are the critical factors leading to the success of Lean Manufacturing implementation at manufacturing companies in Vietnam. Overall, this study provides the suggestions to business managers, especially Vietnamese managers, orienting toward utilizing resource on core activities to efficiently achieve Lean Manufacturing implementation.

  4. Utility of Big Area Additive Manufacturing (BAAM) For The Rapid Manufacture of Customized Electric Vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Love, Lonnie J [ORNL

    2015-08-01

    This Oak Ridge National Laboratory (ORNL) Manufacturing Development Facility (MDF) technical collaboration project was conducted in two phases as a CRADA with Local Motors Inc. Phase 1 was previously reported as Advanced Manufacturing of Complex Cyber Mechanical Devices through Community Engagement and Micro-manufacturing and demonstrated the integration of components onto a prototype body part for a vehicle. Phase 2 was reported as Utility of Big Area Additive Manufacturing (BAAM) for the Rapid Manufacture of Customized Electric Vehicles and demonstrated the high profile live printing of an all-electric vehicle using ONRL s Big Area Additive Manufacturing (BAAM) technology. This demonstration generated considerable national attention and successfully demonstrated the capabilities of the BAAM system as developed by ORNL and Cincinnati, Inc. and the feasibility of additive manufacturing of a full scale electric vehicle as envisioned by the CRADA partner Local Motors, Inc.

  5. Collaborative Cloud Manufacturing: Design of Business Model Innovations Enabled by Cyberphysical Systems in Distributed Manufacturing Systems

    Directory of Open Access Journals (Sweden)

    Erwin Rauch

    2016-01-01

    Full Text Available Collaborative cloud manufacturing, as a concept of distributed manufacturing, allows different opportunities for changing the logic of generating and capturing value. Cyberphysical systems and the technologies behind them are the enablers for new business models which have the potential to be disruptive. This paper introduces the topics of distributed manufacturing as well as cyberphysical systems. Furthermore, the main business model clusters of distributed manufacturing systems are described, including collaborative cloud manufacturing. The paper aims to provide support for developing business model innovations based on collaborative cloud manufacturing. Therefore, three business model architecture types of a differentiated business logic are discussed, taking into consideration the parameters which have an influence and the design of the business model and its architecture. As a result, new business models can be developed systematically and new ideas can be generated to boost the concept of collaborative cloud manufacturing within all sustainable business models.

  6. Lean Manufacturing Auto Cluster at Chennai

    Science.gov (United States)

    Bhaskaran, E.

    2012-10-01

    Due the presence of lot of automotive Industry, Chennai is known as Detroit of India, that producing over 40 % of the Indian vehicle and components. Lean manufacturing concepts have been widely recognized as an important tool in improving the competitiveness of industries. This is a continuous process involving everyone, starting from management to the shop floor. Automotive Component Industries (ACIs) in Ambattur Industrial Estate, Chennai has formed special purpose vehicle (SPV) society namely Ambattur Industrial Estate Manufacturers Association (AIEMA) Technology Centre (ATC) lean manufacturing cluster (ATC-LMC) during July 2010 under lean manufacturing competitiveness scheme, that comes under National Manufacturing Competitiveness Programme of Government of India. The Tripartite Agreement is taken place between National Productivity Council, consultants and cluster (ATC-LMC). The objective is to conduct diagnostic study, study on training and application of various lean manufacturing techniques and auditing in ten ACIs. The methodology adopted is collection of primary data/details from ten ACIs. In the first phase, diagnostic study is done and the areas for improvement in each of the cluster member companies are identified. In the second phase, training programs and implementation is done on 5S and other areas. In the third phase auditing is done and found that the lean manufacturing techniques implementation in ATC-LMC is sustainable and successful in every cluster companies, which will not only enhance competitiveness but also decrease cost, time and increase productivity. The technical efficiency of LMC companies also increases significantly.

  7. Lighting molded optics: Design and manufacturing

    Directory of Open Access Journals (Sweden)

    Kočárková H.

    2013-05-01

    Full Text Available Proper design and manufacturing of glass molded lenses need to be performed in several steps. The whole process from customer requirements to f nal functional product is shown on two examples - a lens for street light and a lens for spot light with narrow lighting angle. After discussing customer requirements, optical design is made. Thanks to various commercial softwares with optimization, manufacturer of the lens can work as well as a designer which enables simplif cation and acceleration of lens manufacturing, since limitations of the manufacturing process are considered during creation of the design. When the prototype is made, its functionality needs to be evaluated. This work shows measurement of light distribution for street light lens in a dark room using goniometer and measurement of light intensity for spot lens f xed on an optical bench. These measurements can reveal the root cause in case of lens malfunction, which enables to optimize manufacturing process or modify lens design accordingly. Designing, manufacturing and evaluation of molded optics under one roof enables creation of easily manufacturable design and fast solution of problems.

  8. Micro-optics: manufacturing and characterization

    Science.gov (United States)

    Voelkel, R.; Eisner, M.; Weible, K. J.

    2005-10-01

    Wafer-based manufacturing of Micro-Optics is based on standard technologies from Semiconductor Industry, like resist coating, lithography, reactive ion etching, deposition, sputtering, and lift-off. These well-established technologies allow the manufacturing of almost any Micro-Optics' structure shape. The excellence of the Micro-Optics component depends much on the proper choice of the manufacturing equipment and the process control. As all processes are standard Semiconductor technology, the quality is merely a question of the budget and the optimization effort. For characterization and testing, the current situation is different. Neither the test equipment from Semiconductor industry nor the test equipment from classical optics manufacturing is suitable to for Micro-Optics. Most of test instruments Micro-Optics industry is using today have been developed by research institutes or by the manufacturing companies themselves. As Micro-Optics is still a niche market, all instruments are built in small series. This lack of suitable test equipment is a major problem for the Micro-Optics industry today. All process optimization in manufacturing is closely related to the capability to measure the quality of the products. We report on the state of the art in wafer-based manufacturing and summarize the standard characterization tools for Micro-Optics.

  9. ITER central solenoid manufacturing R and D

    International Nuclear Information System (INIS)

    Jay Jayakumar, R.; Tsuji, H.; Ohsaki, O.

    2001-01-01

    The International Thermonuclear Experimental Reactor (ITER) Engineering Design Activity (EDA) includes the development of high performance superconductors, high current joints between superconducting cables and insulating materials. Also in the EDA, the resulting products of this R and D are incorporated in a Central Solenoid Model Coil which utilizes full size conductors. The manufacturing of the model coil and components has led to the development of the design, materials, tooling and process which are fully applicable to the manufacture of the ITER relevant CS coil. The R and D is essentially complete and final stages of the CS Model Coil manufacturing are underway. (author)

  10. ITER central solenoid manufacturing R and D

    International Nuclear Information System (INIS)

    Jayakumar, R.J.; Tsuji, H.; Ohsaki, O.

    1999-01-01

    The International Thermonuclear Experimental Reactor (ITER) Engineering Design Activity (EDA) includes the development of high performance superconductors, high current joints between superconducting cables and insulating materials. Also in the EDA, the resulting products of this R and D are incorporated in a Central Solenoid Model Coil which utilizes full size conductors. The manufacturing of the model coil and components has led to the development of the design, materials, tooling and process which are fully applicable to the manufacture of the ITER relevant CS coil. The R and D is essentially complete and final stages of the CS Model Coil manufacturing are underway. (author)

  11. PERSPECTIVES FOR FOG COMPUTING IN MANUFACTURING

    Directory of Open Access Journals (Sweden)

    Jakub PIZOŃ

    2016-09-01

    Full Text Available This article discusses ongoing efforts to enable the fog computing vision in manufacturing. As a new paradigm of computing implementation of fog computing faces many challenges that open perspective of new applications within a field of manufacturing. It is expected that fog computing will be one of factors that will accelerate development of in forth industrial revolution. In this article we discuss the perspectives of manufacturing companies surrounded by new solutions of CPS, CPPS and CM in relation to fog computing.

  12. Simulation approach towards energy flexible manufacturing systems

    CERN Document Server

    Beier, Jan

    2017-01-01

    This authored monograph provides in-depth analysis and methods for aligning electricity demand of manufacturing systems to VRE supply. The book broaches both long-term system changes and real-time manufacturing execution and control, and the author presents a concept with different options for improved energy flexibility including battery, compressed air and embodied energy storage. The reader will also find a detailed application procedure as well as an implementation into a simulation prototype software. The book concludes with two case studies. The target audience primarily comprises research experts in the field of green manufacturing systems. .

  13. Effusion plate using additive manufacturing methods

    Science.gov (United States)

    Johnson, Thomas Edward; Keener, Christopher Paul; Ostebee, Heath Michael; Wegerif, Daniel Gerritt

    2016-04-12

    Additive manufacturing techniques may be utilized to construct effusion plates. Such additive manufacturing techniques may include defining a configuration for an effusion plate having one or more internal cooling channels. The manufacturing techniques may further include depositing a powder into a chamber, applying an energy source to the deposited powder, and consolidating the powder into a cross-sectional shape corresponding to the defined configuration. Such methods may be implemented to construct an effusion plate having one or more channels with a curved cross-sectional geometry.

  14. Breaking Barriers in Polymer Additive Manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Love, Lonnie J [ORNL; Duty, Chad E [ORNL; Post, Brian K [ORNL; Lind, Randall F [ORNL; Lloyd, Peter D [ORNL; Kunc, Vlastimil [ORNL; Peter, William H [ORNL; Blue, Craig A [ORNL

    2015-01-01

    Additive Manufacturing (AM) enables the creation of complex structures directly from a computer-aided design (CAD). There are limitations that prevent the technology from realizing its full potential. AM has been criticized for being slow and expensive with limited build size. Oak Ridge National Laboratory (ORNL) has developed a large scale AM system that improves upon each of these areas by more than an order of magnitude. The Big Area Additive Manufacturing (BAAM) system directly converts low cost pellets into a large, three-dimensional part at a rate exceeding 25 kg/h. By breaking these traditional barriers, it is possible for polymer AM to penetrate new manufacturing markets.

  15. Reconfigurable Manufacturing System Design and Implementation

    DEFF Research Database (Denmark)

    Hadar, Ronen; Bilberg, Arne

    2013-01-01

    Reconfigurable Manufacturing Systems (RMS) have been an increasing area of interest in the research arena. However, it seems that current literature is lacking application and implementation cases where RMS are simulated, tested, and evaluated as a feasible manufacturing concept. A Manufacturer...... is meant primarily to show the physical feasibility of the system and provide a first-look into a real production application of the RMS ideas. The purpose of this paper is to present the design of the manufacturer’s RMS proof of concept, its implementation, and evaluation results....

  16. Green electronics manufacturing creating environmental sensible products

    CERN Document Server

    Wang, John X

    2012-01-01

    Going ""green"" is becoming a major component of the mission for electronics manufacturers worldwide. While this goal seems simplistic, it poses daunting dilemmas. Yet, to compete effectively in the global economy, manufacturers must take the initiative to drive this crucial movement. Green Electronics Manufacturing: Creating Environmental Sensible Products provides you with a complete reference to design, develop, build, and install an electronic product with special consideration for the product's environmental impacts during its whole life cycle. The author discusses how to integrate the st

  17. Early cost estimation for additive manufacture

    OpenAIRE

    Zhai, Yun

    2012-01-01

    Additive Manufacture (AM) is a novel manufacturing method; it is a process of forming components by adding materials. Owing to material saving and manufacturing cost saving, more and more research has been focused on metal AM technologies. WAAM is one AM technology, using arc as the heat sources and wire as the material to create parts with weld beads on a layer-by-layer basis. The process can produce components in a wide range of materials, including aluminum, titanium and steel. High deposi...

  18. Telefacturing Based Distributed Manufacturing Environment for Optimal Manufacturing Service by Enhancing the Interoperability in the Hubs

    Directory of Open Access Journals (Sweden)

    V. K. Manupati

    2017-01-01

    Full Text Available Recent happenings are surrounding the manufacturing sector leading to intense progress towards the development of effective distributed collaborative manufacturing environments. This evolving collaborative manufacturing not only focuses on digitalisation of this environment but also necessitates service-dependent manufacturing system that offers an uninterrupted approach to a number of diverse, complicated, dynamic manufacturing operations management systems at a common work place (hub. This research presents a novel telefacturing based distributed manufacturing environment for recommending the manufacturing services based on the user preferences. The first step in this direction is to deploy the most advanced tools and techniques, that is, Ontology-based Protégé 5.0 software for transforming the huge stored knowledge/information into XML schema of Ontology Language (OWL documents and Integration of Process Planning and Scheduling (IPPS for multijobs in a collaborative manufacturing system. Thereafter, we also investigate the possibilities of allocation of skilled workers to the best feasible operations sequence. In this context, a mathematical model is formulated for the considered objectives, that is, minimization of makespan and total training cost of the workers. With an evolutionary algorithm and developed heuristic algorithm, the performance of the proposed manufacturing system has been improved. Finally, to manifest the capability of the proposed approach, an illustrative example from the real-time manufacturing industry is validated for optimal service recommendation.

  19. Unified Controller Design for Intelligent Manufacturing Automation

    National Research Council Canada - National Science Library

    Kosut, Robert

    1997-01-01

    .... The demonstration system selected was rapid thermal processing (RTP) of semiconductor wafers. This novel approach in integrated circuit manufacturing demands fast tracking control laws that achieve near uniform spatial temperature distributions...

  20. Exploiting HRM in support of lean manufacturing

    DEFF Research Database (Denmark)

    Jørgensen, Frances; Matthiesen, Rikke

    The purpose of this paper is to investigate the ways in HRM practices are-and could potentially be-exploited to support lean manufacturing in practice. First, a review of the pertinent literature regarding HRM, SHRM, and lean manufacturing is presented to provide an understanding of the mechanisms...... by which HRM practices could, theoretically, be used to support a lean implementation. Data presented in the paper are derived from 1) a longitudinal case study on lean implementation and 2) from managers currently involved with lean manufacturing in a second company. The relevant literature and the data......'s contribution to the change process itself and through bundling particular HRM practices that are aligned with the lean strategy. The paper contributes to both theory and practice, by suggesting specific ways in which HRM can be strategically aligned with a major change implementation such as lean manufacturing....