WorldWideScience

Sample records for single-ion implantation sii

  1. Silicone implant incompatibility syndrome (SIIS) in a 57-year-old woman with unilateral silicone breast implant

    DEFF Research Database (Denmark)

    Schierbeck, Juliane; Davidsen, Jesper Rømhild; Grindsted Nielsen, Sanne

    2017-01-01

    implants can lead to different interstitial lung manifestations predominantly with granuloma evolvement, leading to the so-called silicone implant incompatibility syndrome (SIIS). This case describes a 57-year-old woman with multiple lung infiltrations and a left-sided breast implant. The implant had been...

  2. Single-Ion Implantation for the Development of Si-Based MOSFET Devices with Quantum Functionalities

    Directory of Open Access Journals (Sweden)

    Jeffrey C. McCallum

    2012-01-01

    Full Text Available Interest in single-ion implantation is driven in part by research into development of solid-state devices that exhibit quantum behaviour in their electronic or optical characteristics. Here, we provide an overview of international research work on single ion implantation and single ion detection for development of electronic devices for quantum computing. The scope of international research into single ion implantation is presented in the context of our own research in the Centre for Quantum Computation and Communication Technology in Australia. Various single ion detection schemes are presented, and limitations on dopant placement accuracy due to ion straggling are discussed together with pathways for scale-up to multiple quantum devices on the one chip. Possible future directions for ion implantation in quantum computing and communications are also discussed.

  3. Development of a keV single-ion-implanter for nanofabrication

    International Nuclear Information System (INIS)

    Yang, C.; Jamieson, D.N.; Hopf, T.; Tamanyan, G.; Spizziri, P.; Pakes, C.; Andresen, S.E.; Hudson, F.; Gauja, E.; Dzurak, A.; Clark, R.G.

    2005-01-01

    Traditional methods of doping semiconductors have a difficulty meeting the demand for high precision doping due to large statistical fluctuations in the numbers of dopant atoms introduced in the ever shrinking volume in micro- and nano-electronics devices, especially when the fabrication process approaches the nanometre scale. The statistical fluctuations in doping semiconductors for the fabrication of devices with a very small feature size may lead to inconsistent and unreliable performance. This paper describes the adaptation of a commercial ion implanter into a single-ion-implantation system for the accurate delivery of dopants into a nanometre or micrometre area in a silicon substrate. All the implanted ions can be accurately counted with near 100% certainty through online detection using the silicon substrate itself as an ion detector. A variety of ion species including B + , N + , P + at the energy range of 10-15 keV can be delivered in the single ion implantation system. (author). 6 refs., 6 figs

  4. Single ion implantation for single donor devices using Geiger mode detectors

    International Nuclear Information System (INIS)

    Bielejec, E; Seamons, J A; Carroll, M S

    2010-01-01

    Electronic devices that are designed to use the properties of single atoms such as donors or defects have become a reality with recent demonstrations of donor spectroscopy, single photon emission sources, and magnetic imaging using defect centers in diamond. Ion implantation, an industry standard for atom placement in materials, requires augmentation for single ion capability including a method for detecting a single ion arrival. Integrating single ion detection techniques with the single donor device construction region allows single ion arrival to be assured. Improving detector sensitivity is linked to improving control over the straggle of the ion as well as providing more flexibility in lay-out integration with the active region of the single donor device construction zone by allowing ion sensing at potentially greater distances. Using a remotely located passively gated single ion Geiger mode avalanche diode (SIGMA) detector we have demonstrated 100% detection efficiency at a distance of >75 μm from the center of the collecting junction. This detection efficiency is achieved with sensitivity to ∼600 or fewer electron-hole pairs produced by the implanted ion. Ion detectors with this sensitivity and integrated with a thin dielectric, for example a 5 nm gate oxide, using low energy Sb implantation would have an end of range straggle of -1 and 10 -4 for operation temperatures of ∼300 K and ∼77 K, respectively. Low temperature operation and reduced false, 'dark', counts are critical to achieving high confidence in single ion arrival. For the device performance in this work, the confidence is calculated as a probability of >98% for counting one and only one ion for a false count probability of 10 -4 at an average ion number per gated window of 0.015.

  5. Single ion impact detection and scanning probe aligned ion implantation for quantum bit formation

    International Nuclear Information System (INIS)

    Weis, Christoph D.

    2011-01-01

    Quantum computing and quantum information processing is a promising path to replace classical information processing via conventional computers which are approaching fundamental physical limits. Instead of classical bits, quantum bits (qubits) are utilized for computing operations. Due to quantum mechanical phenomena such as superposition and entanglement, a completely different way of information processing is achieved, enabling enhanced performance for certain problem sets. Various proposals exist on how to realize a quantum bit. Among them are electron or nuclear spins of defect centers in solid state systems. Two such candidates with spin degree of freedom are single donor atoms in silicon and nitrogen vacancy (NV) defect centers in diamond. Both qubit candidates possess extraordinary qualities which makes them promising building blocks. Besides certain advantages, the qubits share the necessity to be placed precisely in their host materials and device structures. A commonly used method is to introduce the donor atoms into the substrate materials via ion implantation. For this, focused ion beam systems can be used, or collimation techniques as in this work. A broad ion beam hits the back of a scanning probe microscope (SPM) cantilever with incorporated apertures. The high resolution imaging capabilities of the SPM allows the non destructive location of device areas and the alignment of the cantilever and thus collimated ion beam spot to the desired implant locations. In this work, this technique is explored, applied and pushed forward to meet necessary precision requirements. The alignment of the ion beam to surface features, which are sensitive to ion impacts and thus act as detectors, is demonstrated. The technique is also used to create NV center arrays in diamond substrates. Further, single ion impacts into silicon device structures are detected which enables deliberate single ion doping.

  6. Single ion impact detection and scanning probe aligned ion implantation for quantum bit formation

    Energy Technology Data Exchange (ETDEWEB)

    Weis, Christoph D.

    2011-10-04

    Quantum computing and quantum information processing is a promising path to replace classical information processing via conventional computers which are approaching fundamental physical limits. Instead of classical bits, quantum bits (qubits) are utilized for computing operations. Due to quantum mechanical phenomena such as superposition and entanglement, a completely different way of information processing is achieved, enabling enhanced performance for certain problem sets. Various proposals exist on how to realize a quantum bit. Among them are electron or nuclear spins of defect centers in solid state systems. Two such candidates with spin degree of freedom are single donor atoms in silicon and nitrogen vacancy (NV) defect centers in diamond. Both qubit candidates possess extraordinary qualities which makes them promising building blocks. Besides certain advantages, the qubits share the necessity to be placed precisely in their host materials and device structures. A commonly used method is to introduce the donor atoms into the substrate materials via ion implantation. For this, focused ion beam systems can be used, or collimation techniques as in this work. A broad ion beam hits the back of a scanning probe microscope (SPM) cantilever with incorporated apertures. The high resolution imaging capabilities of the SPM allows the non destructive location of device areas and the alignment of the cantilever and thus collimated ion beam spot to the desired implant locations. In this work, this technique is explored, applied and pushed forward to meet necessary precision requirements. The alignment of the ion beam to surface features, which are sensitive to ion impacts and thus act as detectors, is demonstrated. The technique is also used to create NV center arrays in diamond substrates. Further, single ion impacts into silicon device structures are detected which enables deliberate single ion doping.

  7. A reliable method for the counting and control of single ions for single-dopant controlled devices

    International Nuclear Information System (INIS)

    Shinada, T; Kurosawa, T; Nakayama, H; Zhu, Y; Hori, M; Ohdomari, I

    2008-01-01

    By 2016, transistor device size will be just 10 nm. However, a transistor that is doped at a typical concentration of 10 18 atoms cm -3 has only one dopant atom in the active channel region. Therefore, it can be predicted that conventional doping methods such as ion implantation and thermal diffusion will not be available ten years from now. We have been developing a single-ion implantation (SII) method that enables us to implant dopant ions one-by-one into semiconductors until the desired number is reached. Here we report a simple but reliable method to control the number of single-dopant atoms by detecting the change in drain current induced by single-ion implantation. The drain current decreases in a stepwise fashion as a result of the clusters of displaced Si atoms created by every single-ion incidence. This result indicates that the single-ion detection method we have developed is capable of detecting single-ion incidence with 100% efficiency. Our method potentially could pave the way to future single-atom devices, including a solid-state quantum computer

  8. Single-ion irradiation: physics, technology and applications

    International Nuclear Information System (INIS)

    Ohdomari, Iwao

    2008-01-01

    Among the various radiation effects which involve the study of radiation environments, responses of materials and devices to radiation, radiation testing and radiation hardening of devices and equipment, this review mainly considers the radiation effects induced by alpha particles and other ions used in semiconductor technology on Si crystals and Si devices. We first describe the single-ion microprobe that enables the study of the site dependence of radiation hardness in a semiconductor device. Next, we describe single-ion implantation as a tool for suppressing fluctuation in device function induced by the discrete number and random position of dopant atoms. Finally, we describe the common features associated with both 'probing' and 'modification' in terms of the nature and behaviour of defect clusters induced by single-ion irradiation. A special feature of the review is that the radiation effects discussed here are induced by 'single' particles, and not by particle beams. Although there is a great amount of accumulated data on radiation effects, they are discussed in the conventional terms of 'dose' or 'fluence,' whose unit is cm -2 . Therefore, this review provides complementary information on radiation effects. (topical review)

  9. Electrophysiological mechanisms of the SI SII SIII electrocardiographic morphology

    International Nuclear Information System (INIS)

    Bayes de Luna, A.; Carrio, I.; Subirana, M.T.; Torner, P.; Cosin, J.; Sagues, F.; Guindo, J.

    1987-01-01

    We studied three groups of individuals by means of spatial-velocity electrocardiograms and thallium-201 myocardial imaging to figure out the electrophysiological explanation of the SI SII SIII electrocardiographic morphology. We studied twelve healthy individuals without SI SII SIII, seven healthy individuals with SI SII SIII and fifteen patients with chronic obstructive pulmonary disease with SI SII SIII. The average values of the QRS-E and QRS-F intervals were higher in the second and third groups than in the first. One patient of the second group and thirteen of the third showed right ventricular enlargement. The slowing down of the right ventricular conduction explained the SI SII SIII morphology in normal individuals in more than half the cases. In patients with chronic obstructive pulmonary disease with SI SII SIII the conduction delay plays an important part in the electrogenesis of the right ventricular enlargement electrocardiographic morphology. We think that these observations can give further data about the electrophysiologic mechanism of the SI SII SIII morphology

  10. Improved single ion cyclotron resonance mass spectroscopy

    International Nuclear Information System (INIS)

    Boyce, K.R.

    1993-01-01

    The author has improved the state of the art for precision mass spectroscopy of a mass doublet to below one part in 10 10 . By alternately loading single ions into a Penning trap, the author has determined the mass ratio M(CO + )/M(N + 2 ) = 0.999 598 887 74(11), an accuracy of 1 x 10 -10 . This is a factor of 4 improvement over previous measurements, and a factor of 10 better than the 1985 atomic mass table adjustment [WAA85a]. Much of the author's apparatus has been rebuilt, increasing the signal-to-noise ratio and improving the reliability of the machine. The typical time needed to make and cool a single ion has been reduced from about half an hour to under 5 minutes. This was done by a combination of faster ion-making and a much faster procedure for driving out ions of the wrong species. The improved S/N, in combination with a much better signal processing algorithm to extract the ion phase and frequency from the author's data, has substantially reduced the time required for the actual measurements. This is important now that the measurement time is a substantial fraction of the cycle time (the time to make a new ion and measure it). The improvements allow over 30 comparisons in one night, compared to 2 per night previously. This not only improves the statistics, but eliminates the possibility of large non-Gaussian errors due to sudden magnetic field shifts

  11. Two technicians apply insulation to S-II second stage

    Science.gov (United States)

    1964-01-01

    Two technicians apply insulation to the outer surface of the S-II second stage booster for the Saturn V moon rocket. The towering 363-foot Saturn V was a multi-stage, multi-engine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.

  12. SII-Based Speech Prepocessing for Intelligibility Improvement in Noise

    DEFF Research Database (Denmark)

    Taal, Cees H.; Jensen, Jesper

    2013-01-01

    filter sets certain frequency bands to zero when they do not contribute to intelligibility anymore. Experiments show large intelligibility improvements with the proposed method when used in stationary speech-shaped noise. However, it was also found that the method does not perform well for speech...... corrupted by a competing speaker. This is due to the fact that the SII is not a reliable intelligibility predictor for fluctuating noise sources. MATLAB code is provided....

  13. Improvement of the Energy Stability of the Single Ion Microbeam

    International Nuclear Information System (INIS)

    Zhan Furu; Qi Xuehong; Xu Mingliang; Chen Lianyun; Yu Zengliang

    2008-01-01

    Energy instability strongly affects the state and the beam size of the single ion microbeam. A facility based on the Generating Voltmeter was developed to improve the energy stability of the CAS-LIBB (Chinese Academy of Sciences, key laboratory of ion beam bioengineering) single ion microbeam. This paper presents the analysis of the energy instability of the single ion microbeam. A simplified theoretical model is set up to calculate the relationship between the energy instability and the beam spot size. By using this technique, the energy instability is adjusted to about 1%. Stable run-time is over 6 hours. The radius of the single ion beam is reduced by 10% compared to the previous one.

  14. Development of pulsation technique for single ion hit system

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, Takuro; Hamano, Tsuyoshi; Hirao, Toshio; Kamiya, Tomihiro [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1996-12-01

    When a high energy heavy ion enters into a substance, high density of ionization and excitement occurrs along its flying trace. Especially, when such an ion enters into a semiconductor cell, a bit inversion called single event is occurred or a phenomenon destroyed element itself on case of the worst is formed. The present semiconductor cell is made in a size of some micron square, as different from its accumulated degree. In order to analyze the single event phenomenon formed by entering ion into such fine region in detail, a technique possible enter heavy ion beam with space resolution under 1 micron to each sample is necessary. In order to develop this technique, a static type high speed beam switch for control of entering a beam into a sample and a single ion detector for detecting entrance of ion into the sample were installed to heavy ion microbeam forming apparatus. The single ion hit system in Takasaki Radiation Chemistry Research Establishment, JAERI succeeded in detection and control technique of the single ion and control of noise due to pulsization and finished development of basic technique of the single ion hit, since now. After today, it is planned to hit actually the single ion onto the sample and evaluate its accuracy. (G.K.)

  15. Single Ion Trapping for the Enriched Xenon Observatory

    Energy Technology Data Exchange (ETDEWEB)

    Waldman, Samuel J.; /Stanford U., Phys. Dept. /SLAC

    2006-03-28

    In the last decade, a variety of neutrino oscillation experiments have established that there is a mass difference between neutrino flavors, without determining the absolute neutrino mass scale. The Enriched Xenon Observatory for neutrinoless double beta decay (EXO) will search for the rare decays of xenon to determine the absolute value of the neutrino mass. The experiment uses a novel technique to minimize backgrounds, identifying the decay daughter product in real time using single ion spectroscopy. Here, we describe single ion trapping and spectroscopy compatible with the EXO detector. We extend the technique of single ion trapping in ultrahigh vacuum to trapping in xenon gas. With this technique, EXO will achieve a neutrino mass sensitivity of {approx_equal} .010 eV.

  16. Feasibility of Observing and Characterizing Single Ion Strikes in Microelectronic Components

    International Nuclear Information System (INIS)

    Dingreville, Remi Philippe Michel; Hattar, Khalid Mikhiel; Bufford, Daniel Charles

    2015-01-01

    The transient degradation of semiconductor device performance under irradiation has long been an issue of concern. A single high-energy charged particle can degrade or permanently destroy the microelectronic component, potentially altering the course or function of the systems. Disruption of the the crystalline structure through the introduction of quasi-stable defect structures can change properties from semiconductor to conductor. Typically, the initial defect formation phase is followed by a recovery phase in which defect-defect or defect-dopant interactions modify the characteristics of the damaged structure. In this LDRD Express, in-situ ion irradiation transmission microscopy (TEM) in-situ TEM experiments combined with atomistic simulations have been conducted to determine the feasibility of imaging and characterizing the defect structure resulting from a single cascade in silicon. In-situ TEM experiments have been conducted to demonstrate that a single ion strike can be observed in Si thin films with nanometer resolution in real time using the in-situ ion irradiation transmission electron microscope (I 3 TEM). Parallel to this experimental effort, ion implantation has been numerically simulated using Molecular Dynamics (MD). This numerical framework provides detailed predictions of the damage and follow the evolution of the damage during the first nanoseconds. The experimental results demonstrate that single ion strike can be observed in prototypical semiconductors.

  17. Single ion counting with a MCP (microchannel plate) detector

    Energy Technology Data Exchange (ETDEWEB)

    Tawara, Hiroko; Sasaki, Shinichi; Miyajima, Mitsuhiro [National Lab. for High Energy Physics, Tsukuba, Ibaraki (Japan); Shibamura, Eido

    1996-07-01

    In this study, a single-ion-counting method using alpha-particle-impact ionization of Ar atoms is demonstrated and the preliminary {epsilon}{sub mcp} for Ar ions with incident energies of 3 to 4.7 keV is determined. The single-ion counting by the MCP is aimed to be performed under experimental conditions as follows: (1) A signal from the MCP is reasonably identified as incidence of single Ar-ion. (2) The counting rate of Ar ions is less than 1 s{sup -1}. (3) The incident Ar ions are not focused on a small part of an active area of the MCP, namely, {epsilon}{sub mcp} is determined with respect to the whole active area of the MCP. So far, any absolute detection efficiency has not been reported under these conditions. (J.P.N.)

  18. Personaliotsinguteenust tasub kasutada siis, kui rahaline kokkuhoid pole esmane / Merike Lees

    Index Scriptorium Estoniae

    Lees, Merike, 1976-

    2006-01-01

    Ilmunud ka: Delovõje Vedomosti 1. veebr. lk. 13. Personaliotsinguteenuse kasutamine on õigustatud siis, kui ettevõttes pole personalispetsialisti ning rahaline kokkuhoid pole esmatähtis. Kommenteerivad: Eero Erastus, Madis Sander ja Marti Rehemaa

  19. Second Stage (S-II) Arrives at Marshall Space Flight Center For Testing

    Science.gov (United States)

    2004-01-01

    The business end of a Second Stage (S-II) slowly emerges from the shipping container as workers prepare to transport the Saturn V component to the testing facility at MSFC. The Second Stage (S-II) underwent vibration and engine firing tests. The towering 363-foot Saturn V was a multi-stage, multi-engine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.

  20. Plastic flow produced by single ion impacts on metals

    International Nuclear Information System (INIS)

    Birtcher, R. C.

    1998-01-01

    Single ion impacts have been observed using in situ transmission electron microscopy and video recording with a time resolution of 33 milliseconds. Gold was irradiated at 50 K and room temperature. Single ion impacts produce holes, modify existing holes, and extrude material into the initial specimen hole and holes formed by other ion impacts. The same behavior is observed at both temperatures. At both temperatures, ion impacts result in craters and ejected material. Ion impacts produce more small craters than large ones for all ion masses, while heavier mass ions produce more and larger craters than lighter mass ions. This comparison is affected by the ion energy. As the energy of an ion is increased, the probability for deposition near the surface decreases and fewer craters are formed. For a given ion mass, crater production depends on the probability for displacement cascade production in the near surface region. Crater and holes are stable at room temperature, however, ion impacts near an existing crater may cause flow of material into the crater either reshaping or annihilating it. Holes and craters result from the explosive outflow of material from the molten zone of near-surface cascades. The outflow may take the form of molten material, a solid lid or an ejected particle. The surface is a major perturbation on displacement cascades resulting from ion impacts

  1. Plastic Flow Induced by Single Ion Impacts on Gold

    International Nuclear Information System (INIS)

    Birtcher, R.C.; Donnelly, S.E.

    1996-01-01

    The formation of holes in thin gold foils as a result of single ion impacts by 200keV Xe ions has been followed using transmission electron microscopy. Video recording provided details of microstructure evolution with a time resolution of 1/30th sec. Hole formation involves the movement by plastic flow of massive amounts of material, on the order of tens of thousands of Au atoms per ion impact. Plastic flow, as a consequence of individual ion impacts, results in a continual filling of both holes and craters as well as a thickening of the gold foil. Changes in morphology during irradiation is attributed to a localized, thermal-spike induced melting, coupled with plastic flow of effected material under the influence of surface forces. copyright 1996 The American Physical Society

  2. Optical observations of the nearby galaxy IC342 with narrow band [SII] and Hα filters. I

    Directory of Open Access Journals (Sweden)

    Vučetić M.M.

    2013-01-01

    Full Text Available We present observations of a portion of the nearby spiral galaxy IC342 using narrow band [SII] and Hα filters. These observations were carried out in November 2011 with the 2m RCC telescope at Rozhen National Astronomical Observatory in Bulgaria. In this paper we report coordinates, diameters, Hα and [SII] fluxes for 203 HII regions detected in two fields of view in IC342 galaxy. The number of detected HII regions is 5 times higher than previously known in these two parts of the galaxy. [Projekat Ministarstva nauke Republike Srbije, br. 176005: Emission nebulae: structure and evolution

  3. Papel del estrés en la intensidad de los síntomas SII

    OpenAIRE

    Pletikosic, Sanda; Tkalčić, Mladenka

    2016-01-01

    Síndrome del intestino irritable se considera un trastorno biopsicosocial, el resultado de la combinación compleja de factores predisponentes, precipitantes y perpetuos. Rasgos de personalidad, estado afectivo y estrés son algunos de los factores relevantes que contribuyen a la calidad de vida más baja y la exacerbación sintomática de los pacientes con SII. Para examinar el papel del estrés en la exacerbación sintomática de SII, el objetivo de este estudio era explorar la relación entre los a...

  4. ["Kuhu me siis läheme? - Eks ikka koju."] / M. J.

    Index Scriptorium Estoniae

    Jõgi, Mall, 1947-

    2016-01-01

    Tutvustus: „Kuhu me siis läheme? - Eks ikka koju.“ : sajandivahetus saksa kirjanduses 200 aastat tagasi : Goethe, Schiller, Tieck, Kleist, Hoffmann, Eichendorff, Büchner, Novalis, Hegel (Schelling? Hölderlin?), Schlegel / saksa keelest valinud ja tõlkinud Mati Sirkel. Tallinn : Eesti Keele Sihtasutus, 2015

  5. Design of a single ion facility and its applications

    Energy Technology Data Exchange (ETDEWEB)

    Cholewa, M.; Saint, A.; Legge, G.J.F. [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1996-12-31

    The use of micro-irradiation techniques in radiobiology is not new; however, the current techniques take advantage of recent developments in particle delivery, focussing detection, image processing, cell recognition and computer control. These developments have generally come from other fields, for example microbeam elemental analysis techniques and single-event upset testing of semiconductor devices. Also in radiation biology there have been important advances in developments of individual cell assays, which allow a wide range of endpoints to be studied with good accuracy at low doses. Many of the studies that are planned involve following the responses of individual cells after a programmed exposure to charged-particle traversals. To probe the radiation sensitivity of a single cell and/or its constituents with a submicron resolution several developments are needed. The essential parameters of the proposed system can be summarised as follows: a focussed beam of ions of 300nm or less at the cell; a reliable (close to 100%) single ion detection; a fast beam switch to prevent second hits; a target holder adapted for the irradiation of wet cells and a fully automated system for cell recognition and single hits. 1 fig.

  6. Design of a single ion facility and its applications

    Energy Technology Data Exchange (ETDEWEB)

    Cholewa, M; Saint, A; Legge, G J.F. [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1997-12-31

    The use of micro-irradiation techniques in radiobiology is not new; however, the current techniques take advantage of recent developments in particle delivery, focussing detection, image processing, cell recognition and computer control. These developments have generally come from other fields, for example microbeam elemental analysis techniques and single-event upset testing of semiconductor devices. Also in radiation biology there have been important advances in developments of individual cell assays, which allow a wide range of endpoints to be studied with good accuracy at low doses. Many of the studies that are planned involve following the responses of individual cells after a programmed exposure to charged-particle traversals. To probe the radiation sensitivity of a single cell and/or its constituents with a submicron resolution several developments are needed. The essential parameters of the proposed system can be summarised as follows: a focussed beam of ions of 300nm or less at the cell; a reliable (close to 100%) single ion detection; a fast beam switch to prevent second hits; a target holder adapted for the irradiation of wet cells and a fully automated system for cell recognition and single hits. 1 fig.

  7. Conduction Mechanisms and Structure of Ionomeric Single-Ion Conductors

    Energy Technology Data Exchange (ETDEWEB)

    Colby, Ralph H. [Pennsylvania State Univ., University Park, PA (United States); Maranas, Janna K. [Pennsylvania State Univ., University Park, PA (United States); Mueller, Karl T. [Pennsylvania State Univ., University Park, PA (United States); Runt, James [Pennsylvania State Univ., University Park, PA (United States); Winey, Karen I. [Univ. of Pennsylvania, Philadelphia, PA (United States)

    2015-03-01

    Our team has designed using DFT (Gaussian) and synthesized low glass transition temperature single-ion conductors that are either polyanions that conduct small cations Li+, Na+, Cs+ or polycations that conduct small anions F-, OH-, Br-. We utilize a wide range of complimentary experimental materials characterization tools to understand ion transport; differential scanning calorimetry, dielectric relaxation spectroscopy, infrared spectroscopy, nuclear magnetic resonance spectroscopy, linear viscoelasticity, X-ray scattering and molecular dynamics simulations. The glass transition temperature Tg needs to be as low as possible to facilitate ion transport, so the nonionic parts of the polymer need to be polar, flexible and have strong solvation interactions with the ions. The lowest Tg we have managed for polyanions conducting Li+ is -60 °C. In contrast, polysiloxanes with PEO side chains and tetrabutylphosphonium cationic side groups have Tg ≈ -75 °C that barely increases with ion content, as anticipated by DFT. A survey of all polyanions in the literature suggests that Tg < -80 °C is needed to achieve the 10-4 S/cm conductivity needed for battery separators.

  8. An automated single ion hit at JAERI heavy ion microbeam to observe individual radiation damage

    International Nuclear Information System (INIS)

    Kamiya, Tomihiro; Sakai, Takuro; Naitoh, Yutaka; Hamano, Tsuyoshi; Hirao, Toshio

    1999-01-01

    Microbeam scanning and a single ion hit technique have been combined to establish an automated beam positioning and single ion hit system at the JAERI Takasaki heavy ion microbeam system. Single ion irradiation on preset points of a sample in various patterns can be performed automatically in a short period. The reliability of the system was demonstrated using CR-39 nuclear track detectors. Single ion hit patterns were achieved with a positioning accuracy of 2 μm or less. In measurement of single event transient current using this system, the reduction of the pulse height by accumulation of radiation damages was observed by single ion injection to the same local areas. This technique showed a possibility to get some quantitative information about the lateral displacement of an individual radiation effect in silicon PIN photodiodes. This paper will give details of the irradiation system and present results from several experiments

  9. Phase equilibrium measurements and the tuning behavior of new sII clathrate hydrates

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Woongchul; Park, Seongmin; Ro, Hyeyoon; Koh, Dong-Yeun; Seol, Jiwoong [Department of Chemical and Biomolecular Engineering (BK21 Program), KAIST, Daejeon 305-701 (Korea, Republic of); Lee, Huen, E-mail: h_lee@kaist.ac.kr [Department of Chemical and Biomolecular Engineering (BK21 Program), KAIST, Daejeon 305-701 (Korea, Republic of); Graduate School of EEWS, KAIST, Daejeon 305-701 (Korea, Republic of)

    2012-01-15

    Graphical abstract: Pyrrolidine and piperidine act as sII clathrate hydrate formers under methane gas. Highlights: > New sII clathrate hydrate formers were proposed: pyrrolidine and piperidine. > Formation of gas hydrate with methane as help gas was confirmed. > NMR, Raman, and XRD patterns were analyzed to identify the hydrate structures. > We measured (L + H + V) phase equilibrium with proposed hydrate formers. > Tuning phenomena increase gas storage in (pyrrolidine + CH{sub 4}) clathrate hydrates. - Abstract: We suggest two types of new amine-type sII formers: pyrrolidine and piperidine. These guest compounds fail to form clathrate hydrate structures with host water, but instead have to combine with light gaseous guest molecules (methane) for enclathration. First, two binary clathrate hydrates of (pyrrolidine + methane) and (piperidine + methane) were synthesized at various amine concentrations. {sup 13}C NMR and Raman analysis were done to identify the clathrate hydrate structure and guest distribution over sII-S and sII-L cages. XRD was also used to find the exact structure and corresponding cell parameters. At a dilute pyrrolidine concentration of less than 5.56 mol%, the tuning phenomenon is observed such that methane molecules surprisingly occupy sII-L cages. At the critical guest concentration of about 0.1 mol%, the cage occupancy ratio reaches the maximum of approximately 0.5. At very dilute guest concentration below 0.1 mol%, the methane molecules fail to occupy large cages on account of their rarefied distribution in the network. Direct-release experiments were performed to determine the actual guest compositions in the clathrate hydrate phases. Finally, we measured the clathrate hydrate phase equilibria of (pyrrolidine + methane) and (piperidine + methane).

  10. Phase equilibrium measurements and the tuning behavior of new sII clathrate hydrates

    International Nuclear Information System (INIS)

    Shin, Woongchul; Park, Seongmin; Ro, Hyeyoon; Koh, Dong-Yeun; Seol, Jiwoong; Lee, Huen

    2012-01-01

    Graphical abstract: Pyrrolidine and piperidine act as sII clathrate hydrate formers under methane gas. Highlights: → New sII clathrate hydrate formers were proposed: pyrrolidine and piperidine. → Formation of gas hydrate with methane as help gas was confirmed. → NMR, Raman, and XRD patterns were analyzed to identify the hydrate structures. → We measured (L + H + V) phase equilibrium with proposed hydrate formers. → Tuning phenomena increase gas storage in (pyrrolidine + CH 4 ) clathrate hydrates. - Abstract: We suggest two types of new amine-type sII formers: pyrrolidine and piperidine. These guest compounds fail to form clathrate hydrate structures with host water, but instead have to combine with light gaseous guest molecules (methane) for enclathration. First, two binary clathrate hydrates of (pyrrolidine + methane) and (piperidine + methane) were synthesized at various amine concentrations. 13 C NMR and Raman analysis were done to identify the clathrate hydrate structure and guest distribution over sII-S and sII-L cages. XRD was also used to find the exact structure and corresponding cell parameters. At a dilute pyrrolidine concentration of less than 5.56 mol%, the tuning phenomenon is observed such that methane molecules surprisingly occupy sII-L cages. At the critical guest concentration of about 0.1 mol%, the cage occupancy ratio reaches the maximum of approximately 0.5. At very dilute guest concentration below 0.1 mol%, the methane molecules fail to occupy large cages on account of their rarefied distribution in the network. Direct-release experiments were performed to determine the actual guest compositions in the clathrate hydrate phases. Finally, we measured the clathrate hydrate phase equilibria of (pyrrolidine + methane) and (piperidine + methane).

  11. Second Stage (S-II) Plays Key Role in Apollo missions

    Science.gov (United States)

    1970-01-01

    This photograph of the Saturn V Second Stage (S-II) clearly shows the cluster of five powerful J-2 engines needed to boost the Apollo spacecraft into earth orbit following first stage separation. The towering 363-foot Saturn V was a multi-stage, multi-engine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.

  12. Conflictos cognitivos en el Síndrome del Intestino Irritable (SII: un estudio exploratorio

    Directory of Open Access Journals (Sweden)

    Ruth Benasayag

    2004-01-01

    Full Text Available En este estudio descriptivo transversal se exploran algunas características cognitivas y sintomáticas de 13 pacientes consultantes con Síndrome del Intestino Irritable (SII comparados con una muestra de 63 sujetos no consultantes sin síntomas del SII ni psicopatológicos. El 92% de los primeros cumple criterios para algún trastorno del eje I del DSM-IV y su diagnóstico principal puede agruparse en dos categorías: trastornos por ansiedad y por somatización. En conjunto, los pacientes con SII muestran más conflictos cognitivos detectados mediante la Técnica de Rejilla (TR de Kelly que los sujetos normales. Considerando el subgrupo de trastorno por somatización, se observa una tendencia mucho más acentuada a mostrar mayor número de estos conflictos, así como una tendencia clara a presentar mayor polarización y, a su vez, menor complejidad cognitiva (diferenciación, con respecto tanto a los sujetos asintomáticos como a los diagnosticados por trastorno de ansiedad; por su parte, éstos muestran una menor autoestima.

  13. The Fabrication of Arrays of Single Ions in Silicon via Ion Implantation

    Science.gov (United States)

    2014-02-01

    necessary in the pursuit of further refinement of the standard model, like the widely publicised search for the Higgs boson [327]. Much of the initial...Detectors 2004. [327] G Abbiendi. Search for the standard model Higgs boson at LEP. Physics Letters B, 565(0):61 – 75, 2003. [328] James F. Ziegler. Particle

  14. Saturn V Second Stage (S-II) Ready for Static Test

    Science.gov (United States)

    1965-01-01

    Two workers are dwarfed by the five J-2 engines of the Saturn V second stage (S-II) as they make final inspections prior to a static test firing by North American Space Division. These five hydrogen -fueled engines produced one million pounds of thrust, and placed the Apollo spacecraft into earth orbit before departing for the moon. The towering 363-foot Saturn V was a multi-stage, multi-engine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.

  15. Ferrimagnetic Properties of Bond Dilution Mixed Blume-Capel Model with Random Single-Ion Anisotropy

    International Nuclear Information System (INIS)

    Liu Lei; Yan Shilei

    2005-01-01

    We study the ferrimagnetic properties of spin 1/2 and spin-1 systems by means of the effective field theory. The system is considered in the framework of bond dilution mixed Blume-Capel model (BCM) with random single-ion anisotropy. The investigation of phase diagrams and magnetization curves indicates the existence of induced magnetic ordering and single or multi-compensation points. Special emphasis is placed on the influence of bond dilution and random single-ion anisotropy on normal or induced magnetic ordering states and single or multi-compensation points. Normal magnetic ordering states take on new phase diagrams with increasing randomness (bond and anisotropy), while anisotropy induced magnetic ordering states are always occurrence no matter whether concentration of anisotropy is large or small. Existence and disappearance of compensation points rely strongly on bond dilution and random single-ion anisotropy. Some results have not been revealed in previous papers and predicted by Neel theory of ferrimagnetism.

  16. Optical Observations of M81 Galaxy Group in Narrow Band [SII] and H_alpha Filters: Holmberg IX

    Directory of Open Access Journals (Sweden)

    Arbutina, B.

    2009-12-01

    Full Text Available We present observations of the nearby tidal dwarf galaxy Holmberg IX in M81 galaxy group in narrow band [SII] and H$alpha$ filters, carried out in March and November 2008 with the 2m RCC telescope at NAO Rozhen, Bulgaria. Our search for resident supernova remnants (identified as sources with enhanced [SII] emission relative to their H$alpha$ emission in this galaxy yielded no sources of this kind, besides M&H 10-11 or HoIX X-1. Nevertheless, we found a number of objects with significant H$alpha$ emission that probably represent uncatalogued HII regions.

  17. Exchange interaction of strongly anisotropic tripodal erbium single-ion magnets with metallic surfaces

    DEFF Research Database (Denmark)

    Dreiser, Jan; Wäckerlin, Christian; Ali, Md. Ehesan

    2014-01-01

    We present a comprehensive study of Er(trensal) single-ion magnets deposited in ultrahigh vacuum onto metallic surfaces. X-ray photoelectron spectroscopy reveals that the molecular structure is preserved after sublimation, and that the molecules are physisorbed on Au(111) while they are chemisorbed...... on a Ni thin film on Cu(100) single-crystalline surfaces. X-ray magnetic circular dichroism (XMCD) measurements performed on Au(111) samples covered with molecular monolayers held at temperatures down to 4 K suggest that the easy axes of the strongly anisotropic molecules are randomly oriented...... pathways toward optical addressing of surface-deposited single-ion magnets....

  18. Interaction of electrical stimulation and voluntary hand movement in SII and the cerebellum during simulated therapeutic functional electrical stimulation in healthy adults

    DEFF Research Database (Denmark)

    Iftime-Nielsen, Simona Denisia; Christensen, Mark Schram; Vingborg, Rune Jersin

    2012-01-01

    for FESVOL compared with FES alone in the angular gyrus, middle frontal gyrus and inferior frontal gyrus. These findings indicate that during the VOL condition the cerebellum predicts the sensory consequences of the movement and this reduces the subsequent activation in SII. The decreased SII activity may...

  19. Single-ion conducting diblock terpolymers for lithium-ion batteries

    Science.gov (United States)

    Morris, Melody; Epps, Thomas H., III

    Block polymer (BP) electrolytes provide an attractive route to overcome the competing constraints of high conductivity and mechanical/thermal stability in lithium-ion batteries through nanoscale self-assembly. For example, macromolecules can be engineered such that one domain conducts lithium ions and the other prevents lithium dendrite formation. Herein, we report on the behavior of a single-ion conducting BP electrolyte that was designed to facilitate the transport of lithium ions. These polymers differ from traditional salt-doped BP electrolytes, which require the addition of a lithium salt to bestow conductivity and typically suffer from substantial counterion motion that reduces efficiency. New single-ion BPs were synthesized, and the nanoscale morphologies were determined using small angle X-ray scattering and transmission electron microscopy. Electrolyte performance was measured using AC impedance spectroscopy and DC polarization, and the results were correlated to nanoscale morphology and ion content. Enhanced physical understanding of single-ion BPs was gained by connecting the ion mobility to the chemistry, chain structure, and ion content of the single-ion BP. These studies can be applied to other charged-neutral block polymers to elucidate the effects of ion content on self-assembly and macroscopic properties.

  20. On the single-ion Magnetic Anisotropy of the Rare-Earth Metals

    DEFF Research Database (Denmark)

    Kolmakova, N.P.; Tishin, A.M.; Bohr, Jakob

    1996-01-01

    The temperature dependences of the single-ion magnetic anisotropy constants for Tb and Dy metals are calculated in terms of the multipole moments of the rare-earth ions utilizing the available crystal-field parameters. The results are compared with the existing experimental data....

  1. A simple and rapid method for high-resolution visualization of single-ion tracks

    Directory of Open Access Journals (Sweden)

    Masaaki Omichi

    2014-11-01

    Full Text Available Prompt determination of spatial points of single-ion tracks plays a key role in high-energy particle induced-cancer therapy and gene/plant mutations. In this study, a simple method for the high-resolution visualization of single-ion tracks without etching was developed through the use of polyacrylic acid (PAA-N, N’-methylene bisacrylamide (MBAAm blend films. One of the steps of the proposed method includes exposure of the irradiated films to water vapor for several minutes. Water vapor was found to promote the cross-linking reaction of PAA and MBAAm to form a bulky cross-linked structure; the ion-track scars were detectable at a nanometer scale by atomic force microscopy. This study demonstrated that each scar is easily distinguishable, and the amount of generated radicals of the ion tracks can be estimated by measuring the height of the scars, even in highly dense ion tracks. This method is suitable for the visualization of the penumbra region in a single-ion track with a high spatial resolution of 50 nm, which is sufficiently small to confirm that a single ion hits a cell nucleus with a size ranging between 5 and 20 μm.

  2. A simple and rapid method for high-resolution visualization of single-ion tracks

    Energy Technology Data Exchange (ETDEWEB)

    Omichi, Masaaki [Department of Applied Chemistry, Graduate School of Engineering, Osaka University, Osaka 565-0871 (Japan); Center for Collaborative Research, Anan National College of Technology, Anan, Tokushima 774-0017 (Japan); Choi, Wookjin; Sakamaki, Daisuke; Seki, Shu, E-mail: seki@chem.eng.osaka-u.ac.jp [Department of Applied Chemistry, Graduate School of Engineering, Osaka University, Osaka 565-0871 (Japan); Tsukuda, Satoshi [Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, Sendai, Miyagi 980-8577 (Japan); Sugimoto, Masaki [Japan Atomic Energy Agency, Takasaki Advanced Radiation Research Institute, Gunma, Gunma 370-1292 (Japan)

    2014-11-15

    Prompt determination of spatial points of single-ion tracks plays a key role in high-energy particle induced-cancer therapy and gene/plant mutations. In this study, a simple method for the high-resolution visualization of single-ion tracks without etching was developed through the use of polyacrylic acid (PAA)-N, N’-methylene bisacrylamide (MBAAm) blend films. One of the steps of the proposed method includes exposure of the irradiated films to water vapor for several minutes. Water vapor was found to promote the cross-linking reaction of PAA and MBAAm to form a bulky cross-linked structure; the ion-track scars were detectable at a nanometer scale by atomic force microscopy. This study demonstrated that each scar is easily distinguishable, and the amount of generated radicals of the ion tracks can be estimated by measuring the height of the scars, even in highly dense ion tracks. This method is suitable for the visualization of the penumbra region in a single-ion track with a high spatial resolution of 50 nm, which is sufficiently small to confirm that a single ion hits a cell nucleus with a size ranging between 5 and 20 μm.

  3. Somato-motor haptic processing in posterior inner perisylvian region (SII/pIC of the macaque monkey.

    Directory of Open Access Journals (Sweden)

    Hiroaki Ishida

    Full Text Available The posterior inner perisylvian region including the secondary somatosensory cortex (area SII and the adjacent region of posterior insular cortex (pIC has been implicated in haptic processing by integrating somato-motor information during hand-manipulation, both in humans and in non-human primates. However, motor-related properties during hand-manipulation are still largely unknown. To investigate a motor-related activity in the hand region of SII/pIC, two macaque monkeys were trained to perform a hand-manipulation task, requiring 3 different grip types (precision grip, finger exploration, side grip both in light and in dark conditions. Our results showed that 70% (n = 33/48 of task related neurons within SII/pIC were only activated during monkeys' active hand-manipulation. Of those 33 neurons, 15 (45% began to discharge before hand-target contact, while the remaining neurons were tonically active after contact. Thirty-percent (n = 15/48 of studied neurons responded to both passive somatosensory stimulation and to the motor task. A consistent percentage of task-related neurons in SII/pIC was selectively activated during finger exploration (FE and precision grasping (PG execution, suggesting they play a pivotal role in control skilled finger movements. Furthermore, hand-manipulation-related neurons also responded when visual feedback was absent in the dark. Altogether, our results suggest that somato-motor neurons in SII/pIC likely contribute to haptic processing from the initial to the final phase of grasping and object manipulation. Such motor-related activity could also provide the somato-motor binding principle enabling the translation of diachronic somatosensory inputs into a coherent image of the explored object.

  4. The single-ion anisotropy effects in the mixed-spin ternary-alloy

    Science.gov (United States)

    Albayrak, Erhan

    2018-04-01

    The effect of single-ion anisotropy on the thermal properties of the ternary-alloy in the form of ABpC1-p is investigated on the Bethe lattice (BL) in terms of exact recursion relations. The simulation on the BL consists of placing A atoms (spin-1/2) on the odd shells and randomly placing B (spin-3/2) or C (spin-5/2) atoms with concentrations p and 1 - p, respectively, on the even shells. The phase diagrams are calculated in possible planes spanned by the system parameters: temperature, single-ion anisotropy, concentration and ratio of the bilinear interaction parameters for z = 3 corresponding to the honeycomb lattice. It is found that the crystal field drives the system to the lowest possible state therefore reducing the temperatures of the critical lines in agreement with the literature.

  5. Quantum phase transitions in spin-1 X X Z chains with rhombic single-ion anisotropy

    Science.gov (United States)

    Ren, Jie; Wang, Yimin; You, Wen-Long

    2018-04-01

    We explore numerically the inverse participation ratios in the ground state of one-dimensional spin-1 X X Z chains with the rhombic single-ion anisotropy. By employing the techniques of density-matrix renormalization group, effects of the rhombic single-ion anisotropy on various information theoretical measures are investigated, such as the fidelity susceptibility, the quantum coherence, and the entanglement entropy. Their relations with the quantum phase transitions are also analyzed. The phase transitions from the Y -Néel phase to the large-Ex or the Haldane phase can be well characterized by the fidelity susceptibility. The second-order derivative of the ground-state energy indicates all the transitions are of second order. We also find that the quantum coherence, the entanglement entropy, the Schmidt gap, and the inverse participation ratios can be used to detect the critical points of quantum phase transitions. Results drawn from these quantum information observables agree well with each other. Finally we provide a ground-state phase diagram as functions of the exchange anisotropy Δ and the rhombic single-ion anisotropy E .

  6. Designing Artificial Solid-Electrolyte Interphases for Single-Ion and High-Efficiency Transport in Batteries

    KAUST Repository

    Tu, Zhengyuan; Choudhury, Snehashis; Zachman, Michael J.; Wei, Shuya; Zhang, Kaihang; Kourkoutis, Lena F.; Archer, Lynden A.

    2017-01-01

    energy storage technologies. In lithium-ion batteries, electrolytes with single- or near-single-ion conductivity reduce losses caused by ion polarization. In emergent lithium or sodium metal batteries, they maintain high conductivity at the anode

  7. Subattoampere current induced by single ions in silicon oxide layers of nonvolatile memory cells

    International Nuclear Information System (INIS)

    Cellere, G.; Paccagnella, A.; Larcher, L.; Visconti, A.; Bonanomi, M.

    2006-01-01

    A single ion impinging on a thin silicon dioxide layer generates a number of electron/hole pairs proportional to its linear energy transfer coefficient. Defects generated by recombination can act as a conductive path for electrons that cross the oxide barrier, thanks to a multitrap-assisted mechanism. We present data on the dependence of this phenomenon on the oxide thickness by using floating gate memory arrays. The tiny number of excess electrons stored in these devices allows for extremely high sensitivity, impossible with any direct measurement of oxide leakage current. Results are of particular interest for next generation devices

  8. Heisenberg magnetic chain with single-ion easy-plane anisotropy: Hubbard operators approach

    International Nuclear Information System (INIS)

    Spirin, D.V.; Fridman, Y.A.

    2003-01-01

    We investigate the gap in excitation spectrum of one-dimensional S=1 ferro- and antiferromagnets with easy-plane single-ion anisotropy. The self-consistent modification of Hubbard operators approach which enables to account single-site term exactly is used. For antiferromagnetic model we found Haldane phase that exists up to point D=4J (where D is anisotropy parameter, J is exchange coupling), while quadrupolar phase realizes at larger values of anisotropy. Our results specify those of Golinelli et al. (Phys. Rev. B. 45 (1992) 9798), where similar model was studied. Besides the method gives gap value closer to numerical estimations than usual spin-wave theories

  9. Quantum Heisenberg antiferromagnetic chains with exchange and single-ion anisotropies

    International Nuclear Information System (INIS)

    Peters, D; Selke, W; McCulloch, I P

    2010-01-01

    Using density matrix renormalization group calculations, ground state properties of the spin-1 Heisenberg chain with exchange and quadratic single-ion anisotropies in an external field are studied, for special choices of the two kinds of anisotropies. In particular, the phase diagram includes antiferromagnetic, spin-liquid (or spin-flop), IS2, and supersolid (or biconical) phases. Especially, new features of the spin-liquid and supersolid phases are discussed. Properties of the quantum chains are compared to those of corresponding classical spin chains.

  10. Ionoluminescence analysis of glass scintillators and application to single-ion-hit real-time detection

    Energy Technology Data Exchange (ETDEWEB)

    Yokoyama, Akihito, E-mail: yokoyama.akihito@jaea.go.jp [Graduate School of Science and Technology, Gunma University, 1-5-1 Tenjin-cho, Kiryu, Gunma 376-8515 (Japan); Takasaki Advanced Radiation Research Institute (TARRI), Japan Atomic Energy Agency (JAEA), 1233 Watanuki-machi, Takasaki, Gunma 370-1292 (Japan); Kada, Wataru [Graduate School of Science and Technology, Gunma University, 1-5-1 Tenjin-cho, Kiryu, Gunma 376-8515 (Japan); Satoh, Takahiro; Koka, Masashi [Takasaki Advanced Radiation Research Institute (TARRI), Japan Atomic Energy Agency (JAEA), 1233 Watanuki-machi, Takasaki, Gunma 370-1292 (Japan); Shimada, Keisuke; Yokoata, Yuya; Miura, Kenta; Hanaizumi, Osamu [Graduate School of Science and Technology, Gunma University, 1-5-1 Tenjin-cho, Kiryu, Gunma 376-8515 (Japan)

    2016-03-15

    In this paper, we propose and test a real-time detection system for single-ion hits using mega-electronvolt (MeV)-heavy ions. The system was constructed using G2000 and G9 glass scintillators, as well as an electron-multiplying charge-coupled device (EMCCD) camera combined with an inverted microscope with a 10× objective lens. Commercially available G2000 and G9 glass scintillators, which have been reported to exhibit strong photoluminescence at 489, 543, 585, and 622 nm as a result of the Tb{sup 3+} f–f transition, were employed for highly accurate ionized particle detection. The EMCCD camera had a resolution of 512 × 512 pixels, each with a size of 16 μm × 16 μm, and a maximum linear gain of 8 × 10{sup 5} electrons. For 260-MeV Ne, 3 ion hits/s were detected by our system. The intensity of the ionoluminescence (IL) peak induced by the heavy ions was 140 times the noise intensity. In contrast, the luminous diameter at the full width at half maximum (FWHM) in both the horizontal and vertical directions was calculated to be approximately 4.5 μm. These results suggest that our detection system can accurately detect single-ion hits with a diameter of the order of 1 μm.

  11. Specific properties of the SI and SII somatosensory areas and their effects on motor control: a system neurophysiological study.

    Science.gov (United States)

    Friedrich, Julia; Mückschel, Moritz; Beste, Christian

    2018-03-01

    Sensorimotor integration is essential for successful motor control and the somatosensory modality has been shown to have strong effects on the execution of motor plans. The primary (SI) and the secondary somatosensory (SII) cortices are known to differ in their neuroanatomical connections to prefrontal areas, as well as in their involvement to encode cognitive aspects of tactile processing. Here, we ask whether the area-specific processing architecture or the structural neuroanatomical connections with prefrontal areas determine the efficacy of sensorimotor integration processes for motor control. In a system neurophysiological study including EEG signal decomposition (i.e., residue iteration decomposition, RIDE) and source localization, we investigated this question using vibrotactile stimuli optimized for SI or SII processing. The behavioral data show that when being triggered via the SI area, inhibitory control of motor processes is stronger as when being triggered via the SII area. On a neurophysiological level, these effects were reflected in the C-cluster as a result of a temporal decomposition of EEG data, indicating that the sensory processes affecting motor inhibition modulate the response selection level. These modulations were associated with a stronger activation of the right inferior frontal gyrus extending to the right middle frontal gyrus as parts of a network known to be involved in inhibitory motor control when response inhibition is triggered over SI. In addition, areas important for sensorimotor integration like the postcentral gyrus and superior parietal cortex showed activation differences. The data suggest that connection patterns are more important for sensorimotor integration and control than the more restricted area-specific processing architecture.

  12. A fast online hit verification method for the single ion hit system at GSI

    International Nuclear Information System (INIS)

    Du, G.; Fischer, B.; Barberet, P.; Heiss, M.

    2006-01-01

    For a single ion hit facility built to irradiate specific targets inside biological cells, it is necessary to prove that the ions hit the selected targets reliably because the ion hits usually cannot be seen. That ability is traditionally tested either indirectly by aiming at pre-etched tracks in a nuclear track detector or directly by making the ion tracks inside cells visible using a stain coupled to special proteins produced in response to ion hits. However, both methods are time consuming and hits can be verified only after the experiment. This means that targeting errors in the experiment cannot be corrected during the experiment. Therefore, we have developed a fast online hit verification method that measures the targeting accuracy electronically with a spatial resolution of ±1 μm before cell irradiation takes place. (authors)

  13. Single-ion and single-chain magnetism in triangular spin-chain oxides

    Science.gov (United States)

    Seikh, Md. Motin; Caignaert, Vincent; Perez, Olivier; Raveau, Bernard; Hardy, Vincent

    2017-05-01

    S r4 -xC axM n2Co O9 oxides (x =0 and x =2 ) are found to exhibit magnetic responses typical of single-chain magnets (SCMs) and single-ion magnets (SIMs), two features generally investigated in coordination polymers or complexes. The compound x =0 appears to be a genuine SCM, in that blocking effects associated with slow spin dynamics yield remanence and coercivity in the absence of long-range ordering (LRO). In addition, SIM signatures of nearly identical nature are detected in both compounds, coexisting with SCM in x =0 and with LRO in x =2 . It is also observed that a SCM response can be recovered in x =2 after application of magnetic field. These results suggest that purely inorganic systems could play a valuable role in the topical issue of the interplay among SIM, SCM, and LRO phenomena in low-dimensional magnetism.

  14. Single Ion transient-IBIC analyses of semiconductor devices using a cryogenic temperature stage

    International Nuclear Information System (INIS)

    Laird, J.S.; Bardos, R.; Legge, G.J.F.; Jagadish, C.

    1998-01-01

    A new Transient - IBIC data acquisition and analysis system at MARC is described. A discussion on the need for single ion control and temperature control is also given. The recorded signal is used as the trigger for beam pulsing. The new cryostatic temperature control stage is introduced. Data is presented on line profiles across the edge of a Au-Si junction collected over the temperature range of 25-300K using a developed C-V and I-V variable temperature stage incorporating a liquid helium cryostat. It demonstrates the potential improvements in spatial resolution in materials of long lifetime by mapping on timing windows around the prompt charge component in the charge transient

  15. Dynamics of a single ion in a perturbed Penning trap: Octupolar perturbation

    International Nuclear Information System (INIS)

    Lara, Martin; Salas, J. Pablo

    2004-01-01

    Imperfections in the design or implementation of Penning traps may give rise to electrostatic perturbations that introduce nonlinearities in the dynamics. In this paper we investigate, from the point of view of classical mechanics, the dynamics of a single ion trapped in a Penning trap perturbed by an octupolar perturbation. Because of the axial symmetry of the problem, the system has two degrees of freedom. Hence, this model is ideal to be managed by numerical techniques like continuation of families of periodic orbits and Poincare surfaces of section. We find that, through the variation of the two parameters controlling the dynamics, several periodic orbits emanate from two fundamental periodic orbits. This process produces important changes (bifurcations) in the phase space structure leading to chaotic behavior

  16. Broadband Dielectric Spectroscopy and Quasi-Elastic Neutron Scattering on Single-Ion Polymer Conductors

    Science.gov (United States)

    Soles, Christopher; Peng, Hua-Gen; Page, Kirt; Snyder, Chad; Pandy, Ashoutosh; Jeong, Youmi; Runt, James; NIST Collaboration; Pennsylvania Collaboration

    2011-03-01

    The application of solid polymer electrolytes in rechargeable batteries has not been fully realized after decades of research due to its low conductivity. Dramatic increases of the ion conductivity are needed and this progress requires the understanding of conduction mechanism. We address this topic in two fronts, namely, the effect of plasticizer additives and geometric confinement on the charge transfer mechanism. To this end, we combine broadband dielectric spectroscopy (BDS) to characterize the ion mobility and quasi-elastic neutron scattering (QENS) to quantify segmental motion on a single-ion model polymer electrolyte. Deuterated small molecules were used as plasticizers so that the segmental motion of the polymer electrolyte could be monitored by QENS to understand the mechanism behind the increased conductivity. Anodic aluminum oxide (AAO) membranes with well defined channel sizes are used as the matrix to study the transport of ions solvated in a 1D polymer electrolyte.

  17. Development of noise-suppressed detector for single ion hit system

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, Takuro; Hamano, Tsuyoshi; Suda, Tamotsu; Hirao, Toshio; Kamiya, Tomihiro [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    A noise-suppressed detector for single ion detection has been developed, and combined with the heavy ion microbeam apparatus. This detector consists of a pair of micro channel plates (MCP`s) and a very thin carbon foil. The detection signal is formed by the coincidence of the signals from these MCP`s, so that this detector and the coincidence measurement unit can reduce miscounting in the circuit. The detection efficiency for 15 MeV heavy ions was evaluated to be comparable to that of a silicon surface-barrier detector (SSD) and the miscounting rate was 4 orders lower than the noise rate of a single MCP. The rise time of the detection signal was also estimated. (author)

  18. Influence of strong single-ion anisotropy on phase states of 3D and 2D frustrated magnets

    International Nuclear Information System (INIS)

    Fridman, Yu.A.; Kosmachev, O.A.; Matunin, D.A.; Gorelikov, G.A.; Klevets, Ph.N.

    2010-01-01

    We investigated the influence of strong single-ion anisotropy, exceeding exchange interaction, and frustrated exchange interaction on spin-wave excitation spectra and phase states using the Hubbard operators' technique, allowing the exact account of single-ion anisotropy. The results show that both the homogeneous phases (ferromagnetic and quadrupolar) and the spatially inhomogeneous phase (spiral structure) are possible in the 3D magnetic crystal. The region of existence of the spiral structure is considerably smaller than that in the analogues system, but with weak single-ion anisotropy. The situation is more complex in the 2D system; another spatially inhomogeneous state (the domain structure) can be realized in addition to the spiral magnetic structure. The phase diagrams for both the 3D and 2D systems were plotted.

  19. Somatotopic organization of cortical fields in the lateral sulcus of Homo sapiens: evidence for SII and PV.

    Science.gov (United States)

    Disbrow, E; Roberts, T; Krubitzer, L

    2000-02-28

    The human somatosensory cortex in the Sylvian fissure was examined using functional magnetic resonance imaging to describe the number and internal organization of cortical fields present. Somatic stimuli were applied to the lips, face, hand, trunk, and foot of 18 human subjects. Activity patterns were transposed onto three-dimensional magnetic resonance images of the brain so that the location of activity associated with the different stimuli could be related to specific regions of the cortex. There were several consistent findings. First, there were three regions of activity in the lateral sulcus associated with stimulation of the contralateral body. The most consistent locus of activation was on the upper bank of the lateral sulcus, continuing onto the operculum. The other two areas, one rostral and one caudal to this large central area, were smaller and were activated less consistently. Second, when activity patterns in the large central area resulting from stimulation of all body parts were considered, this region appeared to contain two fields that corresponded in location and somatotopic organization to the second somatosensory area (SII) and the parietal ventral area (PV). Finally, patterns of activation within SII and PV were somewhat variable across subjects. Repeated within-subject stimulus presentation indicated that differences across subjects were not due to inconsistent stimulus presentation. Comparisons with other mammals suggest that some features of organization are found only in primates. It is hypothesized that these features may be associated with manual dexterity and coordination of the hands, a characteristic generally restricted to the primate lineage.

  20. Structural transformations of sVI tert-butylamine hydrates to sII binary hydrates with methane.

    Science.gov (United States)

    Prasad, Pinnelli S R; Sugahara, Takeshi; Sloan, E Dendy; Sum, Amadeu K; Koh, Carolyn A

    2009-10-22

    Binary clathrate hydrates with methane (CH(4), 4.36 A) and tert-butylamine (t-BuNH(2), 6.72 A) as guest molecules were synthesized at different molar concentrations of t-BuNH(2) (1.00-9.31 mol %) with methane at 7.0 MPa and 250 K, and were characterized by powder X-ray diffraction (PXRD) and Raman microscopy. A structural transformation from sVI to sII of t-BuNH(2) hydrate was clearly observed on pressurizing with methane. The PXRD showed sII signatures and the remnant sVI signatures were insignificant, implying the metastable nature of sVI binary hydrates. Raman spectroscopic data on these binary hydrates suggest that the methane molecules occupy the small cages and vacant large cages. The methane storage capacity in this system was nearly doubled to approximately 6.86 wt % for 5.56 mol % > t-BuNH(2) > 1.0 mol %.

  1. Dual-ion implantation into GaAs

    International Nuclear Information System (INIS)

    Sealy, B.J.; Bell, E.C.; Surridge, R.K.; Stephens, K.G.; Ambridge, T.; Heckingbottom, R.

    1976-01-01

    A variety of dual implants have been carried out to test the theory of Ambridge and Heckingbottom (Ambridge, T. and Heckingbottom, R., 1973, Radiat. Effects, vol. 17, 31). After annealing at 700 0 C or 750 0 C a significant enhancement of electrical activity compared with single-ion implants has been obtained for (Ga + Se) and (Sn + Se) implants but the degree of enhancement is dose dependent. The results imply that the dual implantation process is more complex than predicted by the theory and the electrical activity measured seems to be dominated by residual, compensating damage. (author)

  2. Silicon Quantum Dots with Counted Antimony Donor Implants

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Meenakshi [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Center for Integrated Nanotechnologies; Pacheco, Jose L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Center for Integrated Nanotechnologies; Perry, Daniel Lee [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Center for Integrated Nanotechnologies; Garratt, E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Center for Integrated Nanotechnologies; Ten Eyck, Gregory A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Center for Integrated Nanotechnologies; Wendt, Joel R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Center for Integrated Nanotechnologies; Manginell, Ronald P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Center for Integrated Nanotechnologies; Luhman, Dwight [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Center for Integrated Nanotechnologies; Bielejec, Edward S. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Center for Integrated Nanotechnologies; Lilly, Michael [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Center for Integrated Nanotechnologies; Carroll, Malcolm S. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Center for Integrated Nanotechnologies

    2015-10-01

    Deterministic control over the location and number of donors is crucial to donor spin quantum bits (qubits) in semiconductor based quantum computing. A focused ion beam is used to implant close to quantum dots. Ion detectors are integrated next to the quantum dots to sense the implants. The numbers of ions implanted can be counted to a precision of a single ion. Regular coulomb blockade is observed from the quantum dots. Charge offsets indicative of donor ionization, are observed in devices with counted implants.

  3. Electrostatically defined silicon quantum dots with counted antimony donor implants

    Energy Technology Data Exchange (ETDEWEB)

    Singh, M., E-mail: msingh@sandia.gov; Luhman, D. R.; Lilly, M. P. [Sandia National Laboratories, Albuquerque, New Mexico 87185 (United States); Center for Integrated Nanotechnologies, Sandia National Laboratories, Albuquerque, New Mexico 87175 (United States); Pacheco, J. L.; Perry, D.; Garratt, E.; Ten Eyck, G.; Bishop, N. C.; Wendt, J. R.; Manginell, R. P.; Dominguez, J.; Pluym, T.; Bielejec, E.; Carroll, M. S. [Sandia National Laboratories, Albuquerque, New Mexico 87185 (United States)

    2016-02-08

    Deterministic control over the location and number of donors is crucial to donor spin quantum bits (qubits) in semiconductor based quantum computing. In this work, a focused ion beam is used to implant antimony donors in 100 nm × 150 nm windows straddling quantum dots. Ion detectors are integrated next to the quantum dots to sense the implants. The numbers of donors implanted can be counted to a precision of a single ion. In low-temperature transport measurements, regular Coulomb blockade is observed from the quantum dots. Charge offsets indicative of donor ionization are also observed in devices with counted donor implants.

  4. Single ion hit detection set-up for the Zagreb ion microprobe

    Science.gov (United States)

    Smith, R. W.; Karlušić, M.; Jakšić, M.

    2012-04-01

    Irradiation of materials by heavy ions accelerated in MV tandem accelerators may lead to the production of latent ion tracks in many insulators and semiconductors. If irradiation is performed in a high resolution microprobe facility, ion tracks can be ordered by submicrometer positioning precision. However, full control of the ion track positioning can only be achieved by a reliable ion hit detection system that should provide a trigger signal irrespectively of the type and thickness of the material being irradiated. The most useful process that can be utilised for this purpose is emission of secondary electrons from the sample surface that follows the ion impact. The status report of the set-up presented here is based on the use of a channel electron multiplier (CEM) detector mounted on an interchangable sample holder that is inserted into the chamber in a close geometry along with the sample to be irradiated. The set-up has been tested at the Zagreb ion microprobe for different ions and energies, as well as different geometrical arrangements. For energies of heavy ions below 1 MeV/amu, results show that efficient (100%) control of ion impact can be achieved only for ions heavier than silicon. The successful use of the set-up is demonstrated by production of ordered single ion tracks in a polycarbonate film and by monitoring fluence during ion microbeam patterning of Foturan glass.

  5. Development of the IFJ single ion hit facility for cells irradiation

    International Nuclear Information System (INIS)

    Veselov, O.; Polak, W.; Ugenskiene, R.; Hajduk, R.; Lebed, K.; Lekki, J.; Horwacik, T.; Dutkiewicz, E.M.; Maranda, S.; Pieprzyca, T.; Sarnecki, C.; Stachura, Z.; Szklarz, Z.; Styczen, J.

    2005-12-01

    In recent years a single ion hit facility (SIHF) has been constructed at the IFJ ion microprobe. The setup is used for the precise irradiations of living cells by a controlled number of ions. The facility allows investigations in various aspects of biomedical research, such as adaptive response, bystander effect, inverse dose-rate effect, low-dose hypersensitivity, etc. Those investigations have two very important requirements: (i) cells must be examined in their natural state and environment, i.e. without previously being killed, and preferentially, neither fixed nor stained, and (ii) a possibility of automatic irradiation of large number of cells with a computer recognition of their positions must be provided. This work presents some of the crucial features of the off-line and on-line optical systems, including self-developed software responsible for the automatic cell recognition. We also show several tests carried out to determine the efficiency of the whole setup and some segments. In conclusion, the results of our first irradiation measurements performed with living cells are demonstrated. (author)

  6. Diode-like single-ion track membrane prepared by electro-stopping

    International Nuclear Information System (INIS)

    Apel, P.Yu.; Korchev, Yu.E.; Siwy, Z.; Spohr, R.; Yoshida, M.

    2001-01-01

    The preparation of an asymmetric membrane in poly(ethylene terephthalate) (PET) is described, using a combination of chemical and electro-stopping. For this purpose, a single-ion-irradiated PET film is inserted into an electrolytic cell and etched from one side in 9 M sodium hydroxide while bathing the other side in a mixture of 2 M KCl and 2 M HCOOH (1:1 by volume), electrically retracting the OH - ions from the tip of the etch pit during pore break-through. When a preset current has been reached, the etch process is interrupted by replacing the etching solution with acidic 1 M potassium chloride solution. After etching, the current-voltage (I-V) characteristic is determined under symmetric bathing conditions, immersing both sides of the membrane in KCl solutions of identical concentration (0.01-1 M) and pH (3-8). The I-V characteristic is strongly non-linear, comparable to that of an electrical diode. If the polarity during etching is reversed, pushing the OH - ions into the tip of the etch pit, the resulting pores are larger and the degree of asymmetry smaller. The importance of electro-stopping is compared with chemical stopping

  7. Luminescent single-ion magnets from Lanthanoid(III) complexes with monodentate ketone ligands

    Energy Technology Data Exchange (ETDEWEB)

    Kanetomo, Takuya; Ishida, Takayuki, E-mail: takayuki.ishida@uec.ac.jp [Department of Engineering Science, The University of Electro-Communications, Tokyo (Japan)

    2016-02-01

    We synthesized [Ln{sup III}(hfac){sub 3}(H{sub 2}O)(L)] (abbreviated as Ln-L; Ln = Gd, Tb, Eu; L = DTBK (di-t-butyl ketone), BP (benzophenone)), in which the carbonyl oxygen atom was coordinated to the Ln ion center, despite of such bulky substituents. Their crystal structures were determined by means of X-ray diffraction study. Gd-DTBK is completely isomorphous to the di-t-butyl nitroxide derivative and accordingly can be regarded as a model with the ligand spin masked. The ac magnetic susceptibility measurements on Tb-DTBK and -BP showed frequency dependence, characteristic of single-ion magnets. They also displayed photoluminescence in the solid state at room temperature. The quantum yields of the luminescence of Tb-DTBK and -BP (λ{sub ex} = 360 nm) were improved to 57 and 35%, respectively, from that of the starting material [TbI{sup III}(hfac){sub 3}(H{sub 2}O){sub 2}] (28% at λ{sub ex} = 370 nm). Similarly, the quantum yields for Eu-DTBK and -BP were 8 and 15%, respectively, with λ{sub ex} = 400 nm, while that of the starting material [EuI{sup III}(hfac){sub 3}(H{sub 2}O){sub 2}] was 4% at λ{sub ex}=400 nm.

  8. Monte Carlo modeling of Io’s [OI] 6300 Å and [SII] 6716 Å auroral emission in eclipse

    Science.gov (United States)

    Moore, C.; Miki, K.; Goldstein, D. B.; Stapelfeldt, K.; Varghese, P. L.; Trafton, L. M.; Evans, R. W.

    2010-06-01

    We present a Monte Carlo (MC) model of [OI] 6300 Å and [SII] 6716 Å emission from Io entering eclipse. The simulation accounts for the 3-D distribution of SO 2, O, SO, S, and O 2 in Io's atmosphere, several volcanic plumes, and the magnetic field around Io. Thermal electrons from the jovian plasma torus are input along the simulation domain boundaries and move along the magnetic field lines distorted by Io, occasionally participating in collisions with neutrals. We find that the atmospheric asymmetry resulting from varying degrees of atmospheric collapse across Io (due to eclipse ingress) and the presence of volcanoes contributes significantly to the unique morphology of the [OI] 6300 Å emission. The [OI] radiation lifetime of ˜134 s limits the emission to regions that have a sufficiently low neutral density so that intermolecular collisions are rare. We find that at low altitudes (typically Pele, Prometheus, etc.) the number density is large enough (>4 × 10 9 cm -3) to collisionally quench nearly all (>95%) of the excited oxygen for reasonable quenching efficiencies. Upstream (relative to the plasma flow), Io's perturbation of the jovian magnetic field mirrors electrons with high pitch angles, while downstream collisions can trap the electrons. This magnetic field perturbation is one of the main physical mechanisms that results in the upstream/downstream brightness asymmetry in [OI] emission seen in the observation by Trauger et al. (Trauger, J.T., Stapelfeldt, K.R., Ballester, G.E., Clarke, J.I., 1997. HST observations of [OI] emissions from Io in eclipse. AAS-DPS Abstract (1997DPS29.1802T)). There are two other main causes for the observed brightness asymmetry. First, the observation's viewing geometry of the wake spot crosses the dayside atmosphere and therefore the wake's observational field of view includes higher oxygen column density than the upstream side. Second, the phased entry into eclipse results in less atmospheric collapse and thus higher

  9. Comb-shaped single ion conductors based on polyacrylate ethers and lithium alkyl sulfonate

    International Nuclear Information System (INIS)

    Sun Xiaoguang; Hou Jun; Kerr, John B.

    2005-01-01

    Comb-shaped single ion conductors have been synthesized by (1) sulfonation of small molecule chloroethyleneglycols, which, after ion exchange to the Li + salt were then converted to the acrylate by reaction with acryloyl chloride and copolymerized with polyethylene glycol monomethyl ether acrylate (Mn = 454, n = 8) (PAE 8 -co-E 3 SO 3 Li); (2) sulfonation of chloride end groups grafted on to prepolymers of polyacrylate ethers (PAE 8 -g-E n SO 3 Li, n = 2, 3). The highest conductivity at 25 deg. C of 2.0 x 10 -7 S cm -1 was obtained for the PAE 8 -co-E 3 SO 3 Li with a salt concentration of EO/Li = 40. The conductivity of PAE 8 -g-E 3 SO 3 Li is lower than that of PAE 8 -co-E 3 SO 3 Li at similar salt concentrations, which is related to the incomplete sulfonation of the grafted polymer that leads to a lower concentration of Li + . The addition of 50 wt.% of plasticizer, PC/EMC (1/1, v/v), to PAE 8 -g-E 2 SO 3 Li increases the ambient conductivity by three orders of magnitude, which is due to the increased ion mobility in a micro-liquid environment and an increase concentration of free ions as a result of the higher dielectric constant of the solvent. A symmetrical Li/Li cell with an electrolyte membrane consisting of 75 wt.% PC/EMC (1/1, v/v) was cycled at a current density of 100 μA cm -2 at 85 deg. C. The cycling profile showed no concentration polarization after a break-in period during the first few cycles, which was apparently due to reaction of the solvent at the lithium metal surface that reacted with lithium metal to form a stable SEI layer

  10. Hybrid Donor-Dot Devices made using Top-down Ion Implantation for Quantum Computing

    Science.gov (United States)

    Bielejec, Edward; Bishop, Nathan; Carroll, Malcolm

    2012-02-01

    We present progress towards fabricating hybrid donor -- quantum dots (QD) for quantum computing. These devices will exploit the long coherence time of the donor system and the surface state manipulation associated with a QD. Fabrication requires detection of single ions implanted with 10's of nanometer precision. We show in this talk, 100% detection efficiency for single ions using a single ion Geiger mode avalanche (SIGMA) detector integrated into a Si MOS QD process flow. The NanoImplanter (nI) a focused ion beam system is used for precision top-down placement of the implanted ion. This machine has a 10 nm resolution combined with a mass velocity filter, allowing for the use of multi-species liquid metal ion sources (LMIS) to implant P and Sb ions, and a fast blanking and chopping system for single ion implants. The combination of the nI and integration of the SIGMA with the MOS QD process flow establishes a path to fabricate hybrid single donor-dot devices. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  11. Application of heavy-ion microbeam system at Kyoto University: Energy response for imaging plate by single ion irradiation

    International Nuclear Information System (INIS)

    Tosaki, M.; Nakamura, M.; Hirose, M.; Matsumoto, H.

    2011-01-01

    A heavy-ion microbeam system for cell irradiation has been developed using an accelerator at Kyoto University. We have successfully developed proton-, carbon-, fluorine- and silicon-beams in order to irradiate a micro-meter sized area with ion counting, especially single ion irradiation. In the heavy-ion microbeam system, an imaging plate (IP) was utilized for beam diagnostics on the irradiation. The IP is widely used for radiography studies in biology. However, there are a few studies on the low linear energy transfer (LET) by single ions, i.e., low-intensity exposure. Thus we have investigated the energy response for the IP, which can be utilized for microbeam diagnostics.

  12. Quantum phase transitions driven by rhombic-type single-ion anisotropy in the S =1 Haldane chain

    Science.gov (United States)

    Tzeng, Yu-Chin; Onishi, Hiroaki; Okubo, Tsuyoshi; Kao, Ying-Jer

    2017-08-01

    The spin-1 Haldane chain is an example of the symmetry-protected-topological (SPT) phase in one dimension. Experimental realization of the spin chain materials usually involves both the uniaxial-type, D (Sz)2 , and the rhombic-type, E [(Sx)2-(Sy)2] , single-ion anisotropies. Here, we provide a precise ground-state phase diagram for a spin-1 Haldane chain with these single-ion anisotropies. Using quantum numbers, we find that the Z2 symmetry breaking phase can be characterized by double degeneracy in the entanglement spectrum. Topological quantum phase transitions take place on particular paths in the phase diagram, from the Haldane phase to the large-Ex, large-Ey, or large-D phases. The topological critical points are determined by the level spectroscopy method with a newly developed parity technique in the density matrix renormalization group [Phys. Rev. B 86, 024403 (2012), 10.1103/PhysRevB.86.024403], and the Haldane-large-D critical point is obtained with an unprecedented precision, (D/J ) c=0.9684713 (1 ) . Close to this critical point, a small rhombic single-ion anisotropy |E |/J ≪1 can destroy the Haldane phase and bring the system into a y -Néel phase. We propose that the compound [Ni (HF2) (3-Clpy ) 4] BF4 is a candidate system to search for the y -Néel phase.

  13. Designing Artificial Solid-Electrolyte Interphases for Single-Ion and High-Efficiency Transport in Batteries

    KAUST Repository

    Tu, Zhengyuan

    2017-09-21

    Substrates able to rectify transport of ions based on charge and/or size are ubiquitous in biological systems. Electrolytes and interphases that selectively transport electrochemically active ions are likewise of broad interest in all electrical energy storage technologies. In lithium-ion batteries, electrolytes with single- or near-single-ion conductivity reduce losses caused by ion polarization. In emergent lithium or sodium metal batteries, they maintain high conductivity at the anode and stabilize metal deposition by fundamental mechanisms. We report that 20- to 300-nm-thick, single-ion-conducting membranes deposited at the anode enable electrolytes with the highest combination of cation transference number, ionic conductivity, and electrochemical stability reported. By means of direct visualization we find that single-ion membranes also reduce dendritic deposition of Li in liquids. Galvanostatic measurements further show that the electrolytes facilitate long (3 mAh) recharge of full Li/LiNi0.8Co0.15Al0.05O2 (NCA) cells with high cathode loadings (3 mAh cm−2/19.9 mg cm−2) and at high current densities (3 mA cm−2).

  14. Spin dynamics in the single-ion magnet [Er(W5O18) 2 ] 9 -

    Science.gov (United States)

    Mariani, M.; Borsa, F.; Graf, M. J.; Sanna, S.; Filibian, M.; Orlando, T.; Sabareesh, K. P. V.; Cardona-Serra, S.; Coronado, E.; Lascialfari, A.

    2018-04-01

    In this work we present a detailed NMR and μ+SR investigation of the spin dynamics in the new hydrated sodium salt containing the single-ion magnet [Er(W5O18) 2 ] 9 -. The 1HNMR absorption spectra at various applied magnetic fields present a line broadening on decreasing temperature which indicates a progressive spin freezing of the single-molecule magnetic moments. The onset of quasistatic local magnetic fields, due to spin freezing, is observed also in the muon relaxation curves at low temperature. Both techniques yield a local field distribution of the order of 0.1-0.2 T, which appears to be of dipolar origin. On decreasing the temperature, a gradual loss of the 1HNMR signal intensity is observed, a phenomenon known as wipe-out effect. The effect is analyzed quantitatively on the basis of a simple model which relies on the enhancement of the NMR spin-spin, T2-1, relaxation rate due to the slowing down of the magnetic fluctuations. Measurements of spin-lattice relaxation rate T1-1 for 1HNMR and of the muon longitudinal relaxation rate λ show an increase as the temperature is lowered. However, while for the NMR case the signal is lost before reaching the very slow fluctuation region, the muon spin-lattice relaxation λ can be followed until very low temperatures and the characteristic maximum, reached when the electronic spin fluctuation frequency becomes of the order of the muon Larmor frequency, can be observed. At high temperatures, the data can be well reproduced with a simple model based on a single correlation time τ =τ0exp (Δ /T ) for the magnetic fluctuations. However, to fit the relaxation data for both NMR and μ+SR over the whole temperature and magnetic field range, one has to use a more detailed model that takes into account spin-phonon transitions among the E r3 + magnetic sublevels. A good agreement for both proton NMR and μ+SR relaxation is obtained, which confirms the validity of the energy level scheme previously calculated from an

  15. Measuring kinetics of complex single ion channel data using mean-variance histograms.

    Science.gov (United States)

    Patlak, J B

    1993-07-01

    The measurement of single ion channel kinetics is difficult when those channels exhibit subconductance events. When the kinetics are fast, and when the current magnitudes are small, as is the case for Na+, Ca2+, and some K+ channels, these difficulties can lead to serious errors in the estimation of channel kinetics. I present here a method, based on the construction and analysis of mean-variance histograms, that can overcome these problems. A mean-variance histogram is constructed by calculating the mean current and the current variance within a brief "window" (a set of N consecutive data samples) superimposed on the digitized raw channel data. Systematic movement of this window over the data produces large numbers of mean-variance pairs which can be assembled into a two-dimensional histogram. Defined current levels (open, closed, or sublevel) appear in such plots as low variance regions. The total number of events in such low variance regions is estimated by curve fitting and plotted as a function of window width. This function decreases with the same time constants as the original dwell time probability distribution for each of the regions. The method can therefore be used: 1) to present a qualitative summary of the single channel data from which the signal-to-noise ratio, open channel noise, steadiness of the baseline, and number of conductance levels can be quickly determined; 2) to quantify the dwell time distribution in each of the levels exhibited. In this paper I present the analysis of a Na+ channel recording that had a number of complexities. The signal-to-noise ratio was only about 8 for the main open state, open channel noise, and fast flickers to other states were present, as were a substantial number of subconductance states. "Standard" half-amplitude threshold analysis of these data produce open and closed time histograms that were well fitted by the sum of two exponentials, but with apparently erroneous time constants, whereas the mean

  16. Ion implantation

    International Nuclear Information System (INIS)

    Dearnaley, Geoffrey

    1975-01-01

    First, ion implantation in semiconductors is discussed: ion penetration, annealing of damage, gettering, ion implanted semiconductor devices, equipement requirements for ion implantation. The importance of channeling for ion implantation is studied. Then, some applications of ion implantation in metals are presented: study of the corrosion of metals and alloys; influence or ion implantation on the surface-friction and wear properties of metals; hyperfine interactions in implanted metals

  17. Ground-state phase diagram of an (S, S') = (1, 2) spin-alternating chain with competing single-ion anisotropies

    International Nuclear Information System (INIS)

    Tonegawa, T; Okamoto, K; Sakai, T; Kaburagi, M

    2009-01-01

    Employing various numerical methods, we determine the ground-state phase diagram of an (S, S') = (1, 2) spin-alternating chain with antiferromagnetic nearest-neighboring exchange interactions and uniaxial single-ion anisotropies. The resulting phase diagram consists of eight kinds of phases including two phases which accompany the spontaneous breaking of the translational symmetry and a ferrimagnetic phase in which the ground-state magnetization varies continuously with the uniaxial single-ion anisotropy constants for the S=1 and S =2 spins. The appearance of these three phases is attributed to the competition between the uniaxial single-ion anisotropies of both spins.

  18. Thermal properties of the mixed spin-1 and spin-3/2 Ising ferrimagnetic system with two different random single-ion anisotropies

    Science.gov (United States)

    Pereira, J. R. V.; Tunes, T. M.; de Arruda, A. S.; Godoy, M.

    2018-06-01

    In this work, we have performed Monte Carlo simulations to study a mixed spin-1 and spin-3/2 Ising ferrimagnetic system on a square lattice with two different random single-ion anisotropies. This lattice is divided in two interpenetrating sublattices with spins SA = 1 in the sublattice A and SB = 3 / 2 in the sublattice B. The exchange interaction between the spins on the sublattices is antiferromagnetic (J single-ion anisotropies, DiA and DjB , on the sublattices A and B, respectively. We have determined the phase diagram of the model in the critical temperature Tc versus strength of the random single-ion anisotropy D plane and we shown that it exhibits only second-order phase transition lines. We also shown that this system displays compensation temperatures for some cases of the random single-ion distribution.

  19. Phase diagrams of the ternary alloy with a single-ion anisotropy in the mean-field approximation

    International Nuclear Information System (INIS)

    Dely, J.; Bobak, A.

    2006-01-01

    The phase diagram of the AB p C 1-p ternary alloy consisting of Ising spins S A =32, S B =2, and S C =52 is investigated by the use of a mean-field theory based on the Bogoliubov inequality for the Gibbs free energy. The effect of the single-ion anisotropy on the phase diagrams is discussed by changing values of the parameters in the model Hamiltonian and comparison is made with the recently reported finite-temperature phase diagrams for the ternary alloy having spin S B =1

  20. On the calculation of single ion activity coefficients in homogeneous ionic systems by application of the grand canonical ensemble

    DEFF Research Database (Denmark)

    Sloth, Peter

    1993-01-01

    The grand canonical ensemble has been used to study the evaluation of single ion activity coefficients in homogeneous ionic fluids. In this work, the Coulombic interactions are truncated according to the minimum image approximation, and the ions are assumed to be placed in a structureless......, homogeneous dielectric continuum. Grand canonical ensemble Monte Carlo calculation results for two primitive model electrolyte solutions are presented. Also, a formula involving the second moments of the total correlation functions is derived from fluctuation theory, which applies for the derivatives...... of the individual ionic activity coefficients with respect to the total ionic concentration. This formula has previously been proposed on the basis of somewhat different considerations....

  1. Single-ion triblock copolymer electrolytes based on poly(ethylene oxide) and methacrylic sulfonamide blocks for lithium metal batteries

    Science.gov (United States)

    Porcarelli, Luca; Aboudzadeh, M. Ali; Rubatat, Laurent; Nair, Jijeesh R.; Shaplov, Alexander S.; Gerbaldi, Claudio; Mecerreyes, David

    2017-10-01

    Single-ion conducting polymer electrolytes represent the ideal solution to reduce concentration polarization in lithium metal batteries (LMBs). This paper reports on the synthesis and characterization of single-ion ABA triblock copolymer electrolytes comprising PEO and poly(lithium 1-[3-(methacryloyloxy)propylsulfonyl]-1-(trifluoromethylsulfonyl)imide) blocks, poly(LiMTFSI). Block copolymers are prepared by reversible addition-fragmentation chain transfer polymerization, showing low glass transition temperature (-55 to 7 °C) and degree of crystallinity (51-0%). Comparatively high values of ionic conductivity are obtained (up to ≈ 10-4 S cm-1 at 70 °C), combined with a lithium-ion transference number close to unity (tLi+ ≈ 0.91) and a 4 V electrochemical stability window. In addition to these promising features, solid polymer electrolytes are successfully tested in lithium metal cells at 70 °C providing long lifetime up to 300 cycles, and stable charge/discharge cycling at C/2 (≈100 mAh g-1).

  2. A Nanophase-Separated, Quasi-Solid-State Polymeric Single-Ion Conductor: Polysulfide Exclusion for Lithium–Sulfur Batteries

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jinhong; Song, Jongchan; Lee, Hongkyung; Noh, Hyungjun; Kim, Yun-Jung; Kwon, Sung Hyun; Lee, Seung Geol; Kim, Hee-Tak

    2017-04-19

    Formation of soluble polysulfide (PS), which is a key feature of lithium sulfur (Li–S) batteries, provides a fast redox kinetic based on a liquid–solid mechanism; however, it imposes the critical problem of PS shuttle. Here, we address the dilemma by exploiting a solvent-swollen polymeric single-ion conductor (SPSIC) as the electrolyte medium of the Li–S battery. The SPSIC consisting of a polymeric single-ion conductor and lithium salt-free organic solvents provides Li ion hopping by forming a nanoscale conducting channel and suppresses PS shuttle according to the Donnan exclusion principle when being employed for Li–S batteries. The organic solvents at the interface of the sulfur/carbon composite and SPSIC eliminate the poor interfacial contact and function as a soluble PS reservoir for maintaining the liquid–solid mechanism. Furthermore, the quasi-solid-state SPSIC allows the fabrication of a bipolar-type stack, which promises the realization of a high-voltage and energy-dense Li–S battery.

  3. Network type sp3 boron-based single-ion conducting polymer electrolytes for lithium ion batteries

    Science.gov (United States)

    Deng, Kuirong; Wang, Shuanjin; Ren, Shan; Han, Dongmei; Xiao, Min; Meng, Yuezhong

    2017-08-01

    Electrolytes play a vital role in modulating lithium ion battery performance. An outstanding electrolyte should possess both high ionic conductivity and unity lithium ion transference number. Here, we present a facile method to fabricate a network type sp3 boron-based single-ion conducting polymer electrolyte (SIPE) with high ionic conductivity and lithium ion transference number approaching unity. The SIPE was synthesized by coupling of lithium bis(allylmalonato)borate (LiBAMB) and pentaerythritol tetrakis(2-mercaptoacetate) (PETMP) via one-step photoinitiated in situ thiol-ene click reaction in plasticizers. Influence of kinds and content of plasticizers was investigated and the optimized electrolytes show both outstanding ionic conductivity (1.47 × 10-3 S cm-1 at 25 °C) and high lithium transference number of 0.89. This ionic conductivity is among the highest ionic conductivity exhibited by SIPEs reported to date. Its electrochemical stability window is up to 5.2 V. More importantly, Li/LiFePO4 cells with the prepared single-ion conducting electrolytes as the electrolyte as well as the separator display highly reversible capacity and excellent rate capacity under room temperature. It also demonstrates excellent long-term stability and reliability as it maintains capacity of 124 mA h g-1 at 1 C rate even after 500 cycles without obvious decay.

  4. Aligned ion implantation using scanning probes

    International Nuclear Information System (INIS)

    Persaud, A.

    2006-01-01

    A new technique for precision ion implantation has been developed. A scanning probe has been equipped with a small aperture and incorporated into an ion beamline, so that ions can be implanted through the aperture into a sample. By using a scanning probe the target can be imaged in a non-destructive way prior to implantation and the probe together with the aperture can be placed at the desired location with nanometer precision. In this work first results of a scanning probe integrated into an ion beamline are presented. A placement resolution of about 120 nm is reported. The final placement accuracy is determined by the size of the aperture hole and by the straggle of the implanted ion inside the target material. The limits of this technology are expected to be set by the latter, which is of the order of 10 nm for low energy ions. This research has been carried out in the context of a larger program concerned with the development of quantum computer test structures. For that the placement accuracy needs to be increased and a detector for single ion detection has to be integrated into the setup. Both issues are discussed in this thesis. To achieve single ion detection highly charged ions are used for the implantation, as in addition to their kinetic energy they also deposit their potential energy in the target material, therefore making detection easier. A special ion source for producing these highly charged ions was used and their creation and interactions with solids of are discussed in detail. (orig.)

  5. Hyperfine-Interaction-Driven Suppression of Quantum Tunneling at Zero Field in a Holmium(III) Single-Ion Magnet.

    Science.gov (United States)

    Chen, Yan-Cong; Liu, Jun-Liang; Wernsdorfer, Wolfgang; Liu, Dan; Chibotaru, Liviu F; Chen, Xiao-Ming; Tong, Ming-Liang

    2017-04-24

    An extremely rare non-Kramers holmium(III) single-ion magnet (SIM) is reported to be stabilized in the pentagonal-bipyramidal geometry by a phosphine oxide with a high energy barrier of 237(4) cm -1 . The suppression of the quantum tunneling of magnetization (QTM) at zero field and the hyperfine structures originating from field-induced QTMs can be observed even from the field-dependent alternating-current magnetic susceptibility in addition to single-crystal hysteresis loops. These dramatic dynamics were attributed to the combination of the favorable crystal-field environment and the hyperfine interactions arising from 165 Ho (I=7/2) with a natural abundance of 100 %. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Hyperfine-interaction-driven suppression of quantum tunneling at zero field in a holmium(III) single-ion magnet

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Yan-Cong; Liu, Jun-Liang; Chen, Xiao-Ming; Tong, Ming-Liang [Key Lab. of Bioinorganic and Synthetic Chemistry of Ministry of Education, School of Chemistry, Sun Yat-Sen Univ., Guangzhou (China); Wernsdorfer, Wolfgang [Institut Neel, CNRS and Universite Joseph Fournier, Grenoble (France); Institute of Nanotechnology, Karlsruhe Institute of Technology (Germany); Physikalisches Institut, Karlsruhe Institute of Technology (Germany); Liu, Dan; Chibotaru, Liviu F. [Theory of Nanomaterials Group and INPAC-Institute of Nanoscale Physics and Chemistry, Katholieke Universiteit Leuven (Belgium)

    2017-04-24

    An extremely rare non-Kramers holmium(III) single-ion magnet (SIM) is reported to be stabilized in the pentagonal-bipyramidal geometry by a phosphine oxide with a high energy barrier of 237(4) cm{sup -1}. The suppression of the quantum tunneling of magnetization (QTM) at zero field and the hyperfine structures originating from field-induced QTMs can be observed even from the field-dependent alternating-current magnetic susceptibility in addition to single-crystal hysteresis loops. These dramatic dynamics were attributed to the combination of the favorable crystal-field environment and the hyperfine interactions arising from {sup 165}Ho (I=7/2) with a natural abundance of 100 %. (copyright 2017 Wiley-VCH Verlag GmbH and Co. KGaA, Weinheim)

  7. Single-ion polymer electrolyte membranes enable lithium-ion batteries with a broad operating temperature range.

    Science.gov (United States)

    Cai, Weiwei; Zhang, Yunfeng; Li, Jing; Sun, Yubao; Cheng, Hansong

    2014-04-01

    Conductive processes involving lithium ions are analyzed in detail from a mechanistic perspective, and demonstrate that single ion polymeric electrolyte (SIPE) membranes can be used in lithium-ion batteries with a wide operating temperature range (25-80 °C) through systematic optimization of electrodes and electrode/electrolyte interfaces, in sharp contrast to other batteries equipped with SIPE membranes that display appreciable operability only at elevated temperatures (>60 °C). The performance is comparable to that of batteries using liquid electrolyte of inorganic salt, and the batteries exhibit excellent cycle life and rate performance. This significant widening of battery operation temperatures coupled with the inherent flexibility and robustness of the SIPE membranes makes it possible to develop thin and flexible Li-ion batteries for a broad range of applications. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Finite-temperature dynamic structure factor of the spin-1 XXZ chain with single-ion anisotropy

    Science.gov (United States)

    Lange, Florian; Ejima, Satoshi; Fehske, Holger

    2018-02-01

    Improving matrix-product state techniques based on the purification of the density matrix, we are able to accurately calculate the finite-temperature dynamic response of the infinite spin-1 XXZ chain with single-ion anisotropy in the Haldane, large-D , and antiferromagnetic phases. Distinct thermally activated scattering processes make a significant contribution to the spectral weight in all cases. In the Haldane phase, intraband magnon scattering is prominent, and the on-site anisotropy causes the magnon to split into singlet and doublet branches. In the large-D phase response, the intraband signal is separated from an exciton-antiexciton continuum. In the antiferromagnetic phase, holons are the lowest-lying excitations, with a gap that closes at the transition to the Haldane state. At finite temperatures, scattering between domain-wall excitations becomes especially important and strongly enhances the spectral weight for momentum transfer π .

  9. Re-examining the tetraphenyl-arsonium/tetraphenyl-borate (TATB) hypothesis for single-ion solvation free energies

    Science.gov (United States)

    Pollard, Travis P.; Beck, Thomas L.

    2018-06-01

    Attempts to establish an absolute single-ion hydration free energy scale have followed multiple strategies. Two central themes consist of (1) employing bulk pair thermodynamic data and an underlying interfacial-potential-free model to partition the hydration free energy into individual contributions [Marcus, Latimer, and tetraphenyl-arsonium/tetraphenyl-borate (TATB) methods] or (2) utilizing bulk thermodynamic and cluster data to estimate the free energy to insert a proton into water, including in principle an interfacial potential contribution [the cluster pair approximation (CPA)]. While the results for the hydration free energy of the proton agree remarkably well between the three approaches in the first category, the value differs from the CPA result by roughly +10 kcal/mol, implying a value for the effective electrochemical surface potential of water of -0.4 V. This paper provides a computational re-analysis of the TATB method for single-ion free energies using quasichemical theory. A previous study indicated a significant discrepancy between the free energies of hydration for the TA cation and the TB anion. We show that the main contribution to this large computed difference is an electrostatic artifact arising from modeling interactions in periodic boundaries. No attempt is made here to develop more accurate models for the local ion/solvent interactions that may lead to further small free energy differences between the TA and TB ions, but the results clarify the primary importance of interfacial potential effects for analysis of the various free energy scales. Results are also presented, related to the TATB assumption in the organic solvents dimethyl sulfoxide and 1,2-dichloroethane.

  10. Cochlear Implants

    Science.gov (United States)

    ... implant, including: • How long a person has been deaf, •The number of surviving auditory nerve fibers, and • ... Implant, Severe Sensoryneurial Hearing Loss Get Involved Professional Development Practice Management ENT Careers Marketplace Privacy Policy Terms ...

  11. Isostructural and cage-specific replacement occurring in sII hydrate with external CO2/N2 gas and its implications for natural gas production and CO2 storage

    International Nuclear Information System (INIS)

    Seo, Young-ju; Park, Seongmin; Kang, Hyery; Ahn, Yun-Ho; Lim, Dongwook; Kim, Se-Joon; Lee, Jaehyoung; Lee, Joo Yong; Ahn, Taewoong; Seo, Yongwon; Lee, Huen

    2016-01-01

    Highlights: • The structural sustainability of sII hydrate is demonstrated during the replacement. • The experimental evidence of isostructural replacement is revealed. • The cage-specific replacement in sII hydrates allows long-term CO 2 storage. • The compositions and extent of replacement are cross-checked by GC and NMR analyses. - Abstract: A replacement technique has been regarded as a promising strategy for both CH 4 exploitation from gas hydrates and CO 2 sequestration into deep-ocean reservoirs. Most research has been focused on replacement reactions that occur in sI hydrates due to their prevalence in natural gas hydrates. However, sII hydrates in nature have been also discovered in some regions, and the replacement mechanism in sII hydrates significantly differs from that in sI hydrates. In this study, we have intensively investigated the replacement reaction of sII (C 3 H 8 + CH 4 ) hydrate by externally injecting CO 2 /N 2 (50:50) gas mixture with a primary focus on powder X-ray diffraction, Raman spectroscopy, NMR spectroscopy, and gas chromatography analyses. In particular, it was firstly confirmed that there was no structural transformation during the replacement of C 3 H 8 + CH 4 hydrate with CO 2 /N 2 gas injection, indicating that sII hydrate decomposition followed by sI hydrate formation did not occur. Furthermore, the cage-specific replacement pattern of the C 3 H 8 + CH 4 hydrate revealed that CH 4 replacement with N 2 in the small cages of sII was more significant than C 3 H 8 replacement with CO 2 in the large cages of sII. The total extent of the replacement for the C 3 H 8 + CH 4 hydrate was cross-checked by NMR and GC analyses and found to be approximately 54%. Compared to the replacement for CH 4 hydrate with CO 2 /N 2 gas, the lower extent of the replacement for the C 3 H 8 + CH 4 hydrate with CO 2 /N 2 gas was attributable to the persistent presence of C 3 H 8 in the large cages and the lower content of N 2 in the feed gas. The

  12. Exactly solved mixed spin-(1,1/2) Ising–Heisenberg diamond chain with a single-ion anisotropy

    International Nuclear Information System (INIS)

    Lisnyi, Bohdan; Strečka, Jozef

    2015-01-01

    The mixed spin-(1,1/2) Ising–Heisenberg diamond chain with a single-ion anisotropy is exactly solved through the generalized decoration–iteration transformation and the transfer-matrix method. The decoration–iteration transformation is first used for establishing a rigorous mapping equivalence with the corresponding spin-1 Blume–Emery–Griffiths chain, which is subsequently exactly treated within the transfer-matrix technique. Apart from three classical ground states the model exhibits three striking quantum ground states in which a singlet-dimer state of the interstitial Heisenberg spins is accompanied either with a frustrated state or a polarized state or a non-magnetic state of the nodal Ising spins. It is evidenced that two magnetization plateaus at zero and/or one-half of the saturation magnetization may appear in low-temperature magnetization curves. The specific heat may display remarkable temperature dependences with up to three and four distinct round maxima in a zero and non-zero magnetic field, respectively. - Highlights: • Mixed spin-(1,1/2) Ising–Heisenberg diamond chain is exactly solved. • Quantum ground states with a singlet-dimer state of the Heisenberg spins are found. • Magnetization curve displays intermediate plateaus at zero and half of full magnetization. • Thermal dependences of specific heat may display up to four distinct peaks

  13. U/Th dating by SHRIMP RG ion-microprobe mass spectrometry using single ion-exchange beads

    Science.gov (United States)

    Bischoff, J.L.; Wooden, J.; Murphy, F.; Williams, Ross W.

    2005-01-01

    We present a new analytical method for U-series isotopes using the SHRIMP RG (Sensitive High mass Resolution Ion MicroProbe) mass spectrometer that utilizes the preconcentration of the U-series isotopes from a sample onto a single ion-exchange bead. Ion-microprobe mass spectrometry is capable of producing Th ionization efficiencies in excess of 2%. Analytical precision is typically better than alpha spectroscopy, but not as good as thermal ionization mass spectroscopy (TIMS) and inductively coupled plasma multicollector mass spectrometry (ICP-MS). Like TIMS and ICP-MS the method allows analysis of small samples sizes, but also adds the advantage of rapidity of analysis. A major advantage of ion-microprobe analysis is that U and Th isotopes are analyzed in the same bead, simplifying the process of chemical separation. Analytical time on the instrument is ???60 min per sample, and a single instrument-loading can accommodate 15-20 samples to be analyzed in a 24-h day. An additional advantage is that the method allows multiple reanalyses of the same bead and that samples can be archived for reanalysis at a later time. Because the ion beam excavates a pit only a few ??m deep, the mount can later be repolished and reanalyzed numerous times. The method described of preconcentrating a low concentration sample onto a small conductive substrate to allow ion-microprobe mass spectrometry is potentially applicable to many other systems. Copyright ?? 2005 Elsevier Ltd.

  14. MeV single-ion beam irradiation of mammalian cells using the Surrey vertical nanobeam, compared with broad proton beam and X-ray irradiations

    Energy Technology Data Exchange (ETDEWEB)

    Prakrajang, K. [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Faculty of Science, Maejo University, Chiang Mai 50290 (Thailand); Jeynes, J.C.G.; Merchant, M.J.; Kirkby, K.; Kirkby, N. [Surrey Ion Beam Center, Faculty of Engineering and Physical Science, University of Surrey, Guildford Surrey, GU2 7XH (United Kingdom); Thopan, P. [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Yu, L.D., E-mail: yuld@fnrf.science.cmu.ac.th [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Thailand Center of Excellence in Physics, Commission on Higher Education, 328 Si Ayutthaya Road, Bangkok 10400 (Thailand)

    2013-07-15

    Highlights: •Recently completed nanobeam at the Surrey Ion Beam Centre was used. •3.8-MeV single and broad proton beams irradiated Chinese hamster cells. •Cell survival curves were measured and compared with 300-kV X-ray irradiation. •Single ion irradiation had a lower survival part at ultra-low dose. •It implies hypersensitivity, bystander effect and cell cycle phase of cell death. -- Abstract: As a part of a systematic study on mechanisms involved in physical cancer therapies, this work investigated response of mammalian cells to ultra-low-dose ion beam irradiation. The ion beam irradiation was performed using the recently completed nanobeam facility at the Surrey Ion Beam Centre. A scanning focused vertical ion nano-beam was applied to irradiate Chinese hamster V79 cells. The V79 cells were irradiated in two different beam modes, namely, focused single ion beam and defocused scanning broad ion beam of 3.8-MeV protons. The single ion beam was capable of irradiating a single cell with a precisely controlled number of the ions to extremely low doses. After irradiation and cell incubation, the number of surviving colonies as a function of the number of the irradiating ions was measured for the cell survival fraction curve. A lower survival for the single ion beam irradiation than that of the broad beam case implied the hypersensitivity and bystander effect. The ion-beam-induced cell survival curves were compared with that from 300-kV X-ray irradiation. Theoretical studies indicated that the cell death in single ion irradiation mainly occurred in the cell cycle phases of cell division and intervals between the cell division and the DNA replication. The success in the experiment demonstrated the Surrey vertical nanobeam successfully completed.

  15. Optical observations of the nearby galaxy IC342 with narrow band [SII] and hα filters. II - detection of 16 optically-identified supernova remnant candidates

    Directory of Open Access Journals (Sweden)

    Vučetić M.M.

    2015-01-01

    Full Text Available We present the detection of 16 optical supernova remnant (SNR candidates in the nearby spiral galaxy IC342. The candidates were detected by applying the [Sii]/Hα ratio criterion on observations made with the 2 m RCC telescope at Rozhen National Astronomical Observatory in Bulgaria. In this paper, we report the coordinates, diameters, Hα and [S ii] fluxes for 16 SNRs detected in two fields of view in the IC342 galaxy. Also, we estimate the contamination of total Hα flux from SNRs in the observed portion of IC342 to be 1.4%. This would represent the fractional error when the star formation rate (SFR for this galaxy is derived from the total galaxy’s Hα emission.

  16. Ion implantation

    International Nuclear Information System (INIS)

    Johnson, E.

    1986-01-01

    It is the purpose of the present paper to give a review of surface alloy processing by ion implantation. However, rather than covering this vast subject as a whole, the survey is confined to a presentation of the microstructures that can be found in metal surfaces after ion implantation. The presentation is limited to alloys processed by ion implantation proper, that is to processes in which the alloy compositions are altered significantly by direct injection of the implanted ions. The review is introduced by a presentation of the processes taking place during development of the fundamental event in ion implantation - the collision cascade, followed by a summary of the various microstructures which can be formed after ion implantation into metals. This is compared with the variability of microstructures that can be achieved by rapid solidification processing. The microstructures are subsequently discussed in the light of the processes which, as the implantations proceed, take place during and immediately after formation of the individual collision cascades. These collision cascades define the volumes inside which individual ions are slowed down in the implanted targets. They are not only centres for vigorous agitation but also the sources for formation of excess concentrations of point defects, which will influence development of particular microstructures. A final section presents a selection of specific structures which have been observed in different alloy systems. (orig./GSCH)

  17. The nature of single-ion activity coefficients calculated from potentiometric measurements on cells with liquid junctions

    Energy Technology Data Exchange (ETDEWEB)

    Zarubin, Dmitri P., E-mail: dmitri.zarubin@mtu-net.ru [Department of Physical and Collod Chemistry, Moscow State University of Technology and Management, 73 Zemlyanoi Val, Moscow 109803 (Russian Federation)

    2011-08-15

    Highlights: > Problem of ionic activity coefficients, determined by potentiometry, is reconsidered. > They are found to be functions of mean activity coefficients and transport numbers of ions. > The finding is verified by calculations and comparing the results with reported data. > Calculations are performed for systems with single electrolytes and binary mixtures. - Abstract: Potentiometric measurements on cells with liquid junctions are sometimes used for calculations of single-ion activity coefficients in electrolyte solutions, the incidence of this being increased recently. As surmised by Guggenheim in the 1930s, such coefficients (of ions i), {gamma}{sub i}, are actually complicated functions of mean ionic activity coefficients, {gamma}{sub {+-}}, and transport numbers of ions, t{sub i}. In the present paper specific functions {gamma}{sub i}({gamma}{sub {+-}}, t{sub i}) are derived for a number of cell types with an arbitrary mixture of strong electrolytes in a one-component solvent in the liquid-junction system. The cell types include cells with (i) identical electrodes, (ii) dissimilar electrodes reversible to the same ions, (iii) dissimilar electrodes reversible to ions of opposite charge signs, (iv) dissimilar electrodes reversible to different ions of the same charge sign, and (v) identical reference electrodes and an ion-selective membrane permeable to ions of only one type. Pairs of functions for oppositely charged ions are found to be consistent with the mean ionic activity coefficients as would be expected for pairs of the proper {gamma}{sub i} quantities by definition of {gamma}{sub {+-}}. The functions are tested numerically on some of the reported {gamma}{sub i} datasets that are the more tractable. A generally good agreement is found with data reported for cells with single electrolytes HCl and KCl in solutions, and with binary mixtures in the liquid-junction systems of KCl from the reference solutions and NaCl and HCl from the test solutions. It

  18. Oriented nano-wire formation and selective adhesion on substrates by single ion track reaction in polysilanes

    International Nuclear Information System (INIS)

    Shu Seki; Satoshi Tsukuda, Yoichi Yoshida; Seiichi Tagawa; Masaki Sugimoto; Shigeru Tanaka

    2002-01-01

    1-D nano-sized materials such as carbon nanotubes have attracted much attention as ideal quantum wires for future manufacturing techniques of nano-scaled opto-electronic devices. However it is still difficult to control the sizes, spatial distributions, or positions of nanotubes by conventional synthetic techniques to date. The MeV order heavy ion beams causes ultra-high density energy deposition which can not be realized by any other techniques (lasers, H, etc), and penetrate the polymer target straighforward as long as 1∼100 m depth. the energy deposited area produces non-homogeneous field can be controlled by changing the energy deposition rate of incident ions (LET: linear energy transfer, eV/nm). We found that cross-linking reaction of polysilane derivatives was predominantly caused and gave nano-gel in the chemical core, unlike main chain scission occurring at the outside of the area. high density energy deposition by ion beams causes non-homogeneous crosslinking reaction of polysilane derivatives within a nano-sized cylindrical area along an ion trajectory, and gives -SiC based nano-wires of which sizes (length, thickness) and number densities are completely under control by changing the parameters of incident ion beams and molecular sizes of target polymers. based on the concept pf the single track gelation, the present study demonstrates the formation of cross-linked polysilane nano-wires with the fairly controlled sizes. Recently the techniques of position-selective single ion hitting have been developed for MeV order ion beams, however it is not sufficient to control precisely the positions of the nano-wires on the substrates within sub- m area. in the present study, we report the selective adhesion of anno-wires on Si substrates by the surface treatments before coating, which enables the patterning of planted nano-wires on substrates and/or electrodes as candidates for nano-sized field emissive cathodes or electro-luminescent devices. Some examples of

  19. Carmustine Implant

    Science.gov (United States)

    ... works by slowing or stopping the growth of cancer cells in your body. ... are pregnant, plan to become pregnant, or are breast-feeding. If you become pregnant while receiving carmustine implant, call your doctor. Carmustine may harm the fetus.

  20. Cochlear Implants

    Science.gov (United States)

    ... NIDCD A cochlear implant is a small, complex electronic device that can help to provide a sense ... Hearing Aids Retinitis Pigmentosa - National Eye Institute Telecommunications Relay Services Usher Syndrome Your Baby's Hearing Screening News ...

  1. Synthesis and Characterization of Network Single Ion Conductors(NSIC) Based On Comb-Branched Polyepoxide Ethers and Lithium Bis(allylmalonato)borate

    International Nuclear Information System (INIS)

    Sun, Xiao-Guang; Kerr, John B.

    2004-01-01

    Network single ion conductors (NSICs) based on comb-branch polyepoxide ethers and lithium bis(allylmalonato) borate have been synthesized and thoroughly characterized by means of ionic conductivity measurements, electrochemical impedance and by dynamic mechanical analysis (DMA). The materials have been tested as battery electrolytes by cycling in symmetrical Li/Li half cells and in Li/V 6 O 13 full cells in which the NSIC was used as both binder and electrolyte in the cathode electrode and as the electrolyte separator membrane,. The substitution of the trimethylene oxide (TMO) unit into the side chains in place of ethylene oxide (EO) units increased the polymerion mobility (lower glass transition temperature). However, the ionic conductivity was nearly one and half orders of magnitude lower than the corresponding pure EO based single ion conductor at the same salt concentration. This effect may be ascribed to the lower dielectric constant of the TMO side chains that result in a lower concentration of free conducting lithium cations. For a highly cross-linked system (EO/Li=20), only 47 wt% plasticizing solvent (ethylene carbonate (EC)/ethyl methyl carbonate (EMC), 1/1 by wt) could be taken up and the ionic conductivity was only increased by one order of magnitude over the dry polyelectrolyte while for a less densely crosslinked system (EO/Li=80), up to 75 wt% plasticizer could be taken up and the ionic conductivity was increased by nearly two orders of magnitude. A Li/Li symmetric cell that was cycled at 85 C at a current density of 25(micro)Acm -2 showed no concentration polarization or diffusional relaxation, consistent with a lithium ion transference number of one. However, both the bulk and interfacial impedances increased after 20 cycles, apparently due to continued cross-linking reactions within the membrane and on the surface of the lithium electrodes. A Li/V 6 O 13 full cell constructed using a single ion conductor gel (propylene carbonate (PC)/EMC, 1/1 in

  2. Implantation, recoil implantation, and sputtering

    International Nuclear Information System (INIS)

    Kelly, R.

    1984-01-01

    The implantation and sputtering mechanisms which are relevant to ion bombardment of surfaces are described. These are: collision, thermal, electronic and photon-induced sputtering. 135 refs.; 36 figs.; 9 tabs

  3. Hip Implant Systems

    Science.gov (United States)

    ... Implants and Prosthetics Metal-on-Metal Hip Implants Hip Implants Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Hip implants are medical devices intended to restore mobility ...

  4. Breast reconstruction - implants

    Science.gov (United States)

    Breast implants surgery; Mastectomy - breast reconstruction with implants; Breast cancer - breast reconstruction with implants ... harder to find a tumor if your breast cancer comes back. Getting breast implants does not take as long as breast reconstruction ...

  5. TEM study of the ion beam induced damage during 14 kev P+ implantation in silicon

    International Nuclear Information System (INIS)

    Rubanov, S.; Tamanyan, G.; Hudson, F.; Jamieson, D.N.; McCallum, J.C.; Prawer, S.

    2005-01-01

    The proposed silicon-based quantum computer architecture comprises an array of phosphorus donor atoms (qubits) positioned with nanometre accuracy beneath the surface of a semiconductor host, using a single ion implantation technique. The average depth of the implanted ions (the projected range R p ), lateral range R p 1, and the distribution of ions about that depth can be approximated as two-dimensional Gaussian with standard deviation ΔR p and ΔR p 1 (lateral straggle). Using transmission electron microscopy (TEM) we studied ion beam induced damage after 14 keV P + implantation in Si. The TEM images allowed us to compare the depth of the amorphous cluster formation to R p , R p 1, ΔR p 1 calculated from SRIM and hence determine evidence for the limitation on the accuracy of the position of the implanted ions imposed by straggling. (author). 4 refs., 3 figs

  6. Phase transitions and multicritical points in the mixed spin-32 and spin-2 Ising system with a single-ion anisotropy

    International Nuclear Information System (INIS)

    Bobak, A.; Dely, J.

    2007-01-01

    The effect of a single-ion anisotropy on the phase diagram of the mixed spin-32 and spin-2 Ising system is investigated by the use of a mean-field theory based on the Bogoliubov inequality for the free energy. Topologically different kinds of phase diagrams are achieved by changing values of the parameter in the model Hamiltonian. Besides second-order transitions, lines of first-order transitions terminating either at a tricritical point or an isolated critical point, are found

  7. Understanding the scale of the single ion free energy: A critical test of the tetra-phenyl arsonium and tetra-phenyl borate assumption

    Science.gov (United States)

    Duignan, Timothy T.; Baer, Marcel D.; Mundy, Christopher J.

    2018-06-01

    The tetra-phenyl arsonium and tetra-phenyl borate (TATB) assumption is a commonly used extra-thermodynamic assumption that allows single ion free energies to be split into cationic and anionic contributions. The assumption is that the values for the TATB salt can be divided equally. This is justified by arguing that these large hydrophobic ions will cause a symmetric response in water. Experimental and classical simulation work has raised potential flaws with this assumption, indicating that hydrogen bonding with the phenyl ring may favor the solvation of the TB- anion. Here, we perform ab initio molecular dynamics simulations of these ions in bulk water demonstrating that there are significant structural differences. We quantify our findings by reproducing the experimentally observed vibrational shift for the TB- anion and confirm that this is associated with hydrogen bonding with the phenyl rings. Finally, we demonstrate that this results in a substantial energetic preference of the water to solvate the anion. Our results suggest that the validity of the TATB assumption, which is still widely used today, should be reconsidered experimentally in order to properly reference single ion solvation free energy, enthalpy, and entropy.

  8. Short Implants: New Horizon in Implant Dentistry.

    Science.gov (United States)

    Jain, Neha; Gulati, Manisha; Garg, Meenu; Pathak, Chetan

    2016-09-01

    The choice of implant length is an essential factor in deciding the survival rates of these implants and the overall success of the prosthesis. Placing an implant in the posterior part of the maxilla and mandible has always been very critical due to poor bone quality and quantity. Long implants can be placed in association with complex surgical procedures such as sinus lift and bone augmentation. These techniques are associated with higher cost, increased treatment time and greater morbidity. Hence, there is need for a less invasive treatment option in areas of poor bone quantity and quality. Data related to survival rates of short implants, their design and prosthetic considerations has been compiled and structured in this manuscript with emphasis on the indications, advantages of short implants and critical biomechanical factors to be taken into consideration when choosing to place them. Studies have shown that comparable success rates can be achieved with short implants as those with long implants by decreasing the lateral forces to the prosthesis, eliminating cantilevers, increasing implant surface area and improving implant to abutment connection. Short implants can be considered as an effective treatment alternative in resorbed ridges. Short implants can be considered as a viable treatment option in atrophic ridge cases in order to avoid complex surgical procedures required to place long implants. With improvement in the implant surface geometry and surface texture, there is an increase in the bone implant contact area which provides a good primary stability during osseo-integration.

  9. Implantation, recoil implantation, and sputtering

    International Nuclear Information System (INIS)

    Kelly, R.

    1984-01-01

    Underlying ion-beam modification of surfaces is the more basic subject of particle-surface interaction. The ideas can be grouped into forward and backward features, i.e. those affecting the interior of the target and those leading to particle expulsion. Forward effects include the stopping of the incident particles and the deposition of energy, both governed by integral equations which are easily set up but difficult to solve. Closely related is recoil implantation where emphasis is placed not on the stopping of the incident particles but on their interaction with target atoms with resulting implantation of these atoms. Backward effects, all of which are denoted as sputtering, are in general either of collisional, thermal, electronic, or exfoliational origin. (Auth.)

  10. The Ideal Ionic Liquid Salt Bridge for the Direct Determination of Gibbs Energies of Transfer of Single Ions, Part I: The Concept.

    Science.gov (United States)

    Radtke, Valentin; Ermantraut, Andreas; Himmel, Daniel; Koslowski, Thorsten; Leito, Ivo; Krossing, Ingo

    2018-02-23

    Described is a procedure for the thermodynamically rigorous, experimental determination of the Gibbs energy of transfer of single ions between solvents. The method is based on potential difference measurements between two electrochemical half cells with different solvents connected by an ideal ionic liquid salt bridge (ILSB). Discussed are the specific requirements for the IL with regard to the procedure, thus ensuring that the liquid junction potentials (LJP) at both ends of the ILSB are mostly canceled. The remaining parts of the LJPs can be determined by separate electromotive force measurements. No extra-thermodynamic assumptions are necessary for this procedure. The accuracy of the measurements depends, amongst others, on the ideality of the IL used, as shown in our companion paper Part II. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Dental Implant Surgery

    Science.gov (United States)

    ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, ... to find out more. Wisdom Teeth Management Wisdom Teeth Management An impacted wisdom tooth can damage neighboring ...

  12. Cochlear Implant

    Directory of Open Access Journals (Sweden)

    Mehrnaz Karimi

    1992-04-01

    Full Text Available People with profound hearing loss are not able to use some kinds of conventional amplifiers due to the nature of their loss . In these people, hearing sense is stimulated only when the auditory nerve is activated via electrical stimulation. This stimulation is possible through cochlear implant. In fact, for the deaf people who have good mental health and can not use surgical and medical treatment and also can not benefit from air and bone conduction hearing aids, this device is used if they have normal central auditory system. The basic parts of the device included: Microphone, speech processor, transmitter, stimulator and receiver, and electrode array.

  13. Complications after cardiac implantable electronic device implantations

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nohr, Ellen Aagaard

    2013-01-01

    Complications after cardiac implantable electronic device (CIED) treatment, including permanent pacemakers (PMs), cardiac resynchronization therapy devices with defibrillators (CRT-Ds) or without (CRT-Ps), and implantable cardioverter defibrillators (ICDs), are associated with increased patient...

  14. Multifarious beneficial traits and plant growth promoting potential of Serratia marcescens KiSII and Enterobacter sp. RNF 267 isolated from the rhizosphere of coconut palms (Cocos nucifera L.).

    Science.gov (United States)

    George, Priya; Gupta, Alka; Gopal, Murali; Thomas, Litty; Thomas, George V

    2013-01-01

    Two plant growth promoting bacteria designated as KiSII and RNF 267 isolated from the rhizosphere of coconut palms were identified as Serratia marcescens and Enterobacter sp. based on their phenotypic features, BIOLOG studies and 16S rRNA gene sequence analysis. Both bacteria exhibited phosphate solubilization, ammonification, and production of indole acetic acid, β-1, 3 glucanase activities and 1-aminocyclopropane-1-carboxylate-deaminase activity. They could also tolerate a range of pH conditions, low temperature and salinity (NaCl). In addition, S. marcescens KiSII exhibited N- fixation potential, chitinase activity, siderophore production and antibiotics production. Seed bacterization with these bacteria increased the growth parameters of test plants such as paddy and cowpea over uninoculated control in green house assay. In coconut seedlings, significant increase in growth and nutrient uptake accompanied with higher populations of plant beneficial microorganisms in their rhizospheres were recorded on inoculation with both the PGPRs. The present study clearly revealed that PGPRs can aid in production of healthy and vigorous seedlings of coconut palm which are hardy perennial crops. They offer a scope to be developed into novel PGPR based bioinoculants for production of elite seedlings that can benefit the coconut farming community and the coconut based ecology.

  15. Retrograde peri-implantitis

    Directory of Open Access Journals (Sweden)

    Mohamed Jumshad

    2010-01-01

    Full Text Available Retrograde peri-implantitis constitutes an important cause for implant failure. Retrograde peri-implantitis may sometimes prove difficult to identify and hence institution of early treatment may not be possible. This paper presents a report of four cases of (the implant placed developing to retrograde peri-implantitis. Three of these implants were successfully restored to their fully functional state while one was lost due to extensive damage. The paper highlights the importance of recognizing the etiopathogenic mechanisms, preoperative assessment, and a strong postoperative maintenance protocol to avoid retrograde peri-implant inflammation.

  16. Individual titanium zygomatic implant

    Science.gov (United States)

    Nekhoroshev, M. V.; Ryabov, K. N.; Avdeev, E. V.

    2018-03-01

    Custom individual implants for the reconstruction of craniofacial defects have gained importance due to better qualitative characteristics over their generic counterparts – plates, which should be bent according to patient needs. The Additive Manufacturing of individual implants allows reducing cost and improving quality of implants. In this paper, the authors describe design of zygomatic implant models based on computed tomography (CT) data. The fabrication of the implants will be carried out with 3D printing by selective laser melting machine SLM 280HL.

  17. Silicon quantum dots with counted antimony donor implants

    Science.gov (United States)

    Singh, Meenakshi; Pacheco, Jose; Perry, Daniel; Wendt, Joel; Manginell, Ronald; Dominguez, Jason; Pluym, Tammy; Luhman, Dwight; Bielejec, Edward; Lilly, Michael; Carroll, Malcolm

    Antimony donor implants next to silicon quantum dots have been detected with integrated solid-state diode detectors with single ion precision. Devices with counted number of donors have been fabricated and low temperature transport measurements have been performed. Charge offsets, indicative of donor ionization and coupling to the quantum dot, have been detected in these devices. The number of offsets corresponds to 10-50% of the number of donors counted. We will report on tunneling time measurements and spin readout measurements on the donor offsets. This work was performed, in part, at the Center for Integrated Nanotechnologies, a U.S. DOE Office of Basic Energy Sciences user facility. The work was supported by Sandia National Laboratories Directed Research and Development Program. Sandia National Laboratories is a multi-program laboratory operated by Sandia Corporation, a Lockheed-Martin Company, for the U. S. Department of Energy under Contract No. DE-AC04-94AL85000.

  18. Multiple Quantum Coherences (MQ) NMR and Entanglement Dynamics in the Mixed-Three-Spin XXX Heisenberg Model with Single-Ion Anisotropy

    Science.gov (United States)

    Hamid, Arian Zad

    2016-12-01

    We analytically investigate Multiple Quantum (MQ) NMR dynamics in a mixed-three-spin (1/2,1,1/2) system with XXX Heisenberg model at the front of an external homogeneous magnetic field B. A single-ion anisotropy property ζ is considered for the spin-1. The intensities dependence of MQ NMR coherences on their orders (zeroth and second orders) for two pairs of spins (1,1/2) and (1/2,1/2) of the favorite tripartite system are obtained. It is also investigated dynamics of the pairwise quantum entanglement for the bipartite (sub)systems (1,1/2) and (1/2,1/2) permanently coupled by, respectively, coupling constants J}1 and J}2, by means of concurrence and fidelity. Then, some straightforward comparisons are done between these quantities and the intensities of MQ NMR coherences and ultimately some interesting results are reported. We also show that the time evolution of MQ coherences based on the reduced density matrix of the pair spins (1,1/2) is closely connected with the dynamics of the pairwise entanglement. Finally, we prove that one can introduce MQ coherence of the zeroth order corresponds to the pair spins (1,1/2) as an entanglement witness at some special time intervals.

  19. The field-induced laws of thermodynamic properties in the two-dimensional spin-1 ferromagnetic Heisenberg model with the exchange and single-ion anisotropies

    International Nuclear Information System (INIS)

    Pu Qiurong; Chen Yuan

    2013-01-01

    Green's function method is applied to investigate the two-dimensional spin-1 ferromagnetic Heisenberg model with the exchange and single-ion anisotropies. In the presence of the magnetic field, the effects of the anisotropies and field on the thermodynamic properties are obtained within the random phase approximation combining with Anderson-Callen approximation. The field-induced laws are found for the thermodynamic properties. Field dependences of heights of the susceptibility maximum and specific heat maximum fit well to power laws. The linear increase at high fields is shown for positions of the susceptibility maximum and specific heat maximum. A power law at low fields occurs for the position of the susceptibility maximum. At the positions of the maxima, the magnetization and internal energy display the power-law increase and linear decrease with the field, respectively. The exponents of the power laws are dependent of the anisotropies, as well as the slopes of the linear laws. Our results do not support the 2/3 power law which was obtained by the Landau theory.

  20. Theoretical predictions of the lateral spreading of implanted ions

    International Nuclear Information System (INIS)

    Ashworth, D.G.; Oven, R.

    1986-01-01

    The theoretical model and computer program (AAMPITS-3D) of Ashworth and co-workers for the calculation of three-dimensional distributions of implanted ions in multi-element amorphous targets are extended to show that the lateral rest distribution is gaussian in a form with a lateral standard deviation (lateral-spread function) which is a function of depth beneath the target surface. A method is given whereby this function may be accurately determined from a knowledge of the projected range and chord range rest distribution functions. Examples of the lateral-spread function are given for boron, phosphorus and arsenic ions implanted into silicon and a detailed description is given of how the lateral-spread function may be used in conjunction with the projected range rest distribution function to provide a fully three-dimensional rest distribution of ions implanted into amorphous targets. Examples of normalised single ion isodensity contours computed from AMPITS-3D are compared with those obtained using the previous assumption of a lateral standard deviation which was independent of distance beneath the target surface. (author)

  1. Implantable Medical Devices

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Implantable Medical Devices Updated:Sep 16,2016 For Rhythm Control ... a Heart Attack Introduction Medications Surgical Procedures Implantable Medical Devices • Life After a Heart Attack • Heart Attack ...

  2. Intercavitary implants dosage calculation

    International Nuclear Information System (INIS)

    Rehder, B.P.

    The use of spacial geometry peculiar to each treatment for the attainment of intercavitary and intersticial implants dosage calculation is presented. The study is made in patients with intercavitary implants by applying a modified Manchester technique [pt

  3. Implantable electronic medical devices

    CERN Document Server

    Fitzpatrick, Dennis

    2014-01-01

    Implantable Electronic Medical Devices provides a thorough review of the application of implantable devices, illustrating the techniques currently being used together with overviews of the latest commercially available medical devices. This book provides an overview of the design of medical devices and is a reference on existing medical devices. The book groups devices with similar functionality into distinct chapters, looking at the latest design ideas and techniques in each area, including retinal implants, glucose biosensors, cochlear implants, pacemakers, electrical stimulation t

  4. Critical issues in the formation of quantum computer test structures by ion implantation

    Energy Technology Data Exchange (ETDEWEB)

    Schenkel, T.; Lo, C. C.; Weis, C. D.; Schuh, A.; Persaud, A.; Bokor, J.

    2009-04-06

    The formation of quantum computer test structures in silicon by ion implantation enables the characterization of spin readout mechanisms with ensembles of dopant atoms and the development of single atom devices. We briefly review recent results in the characterization of spin dependent transport and single ion doping and then discuss the diffusion and segregation behaviour of phosphorus, antimony and bismuth ions from low fluence, low energy implantations as characterized through depth profiling by secondary ion mass spectrometry (SIMS). Both phosphorus and bismuth are found to segregate to the SiO2/Si interface during activation anneals, while antimony diffusion is found to be minimal. An effect of the ion charge state on the range of antimony ions, 121Sb25+, in SiO2/Si is also discussed.

  5. Effects of He implantation on radiation induced segregation in Cu-Au and Ni-Si alloys

    Science.gov (United States)

    Iwase, A.; Rehn, L. E.; Baldo, P. M.; Funk, L.

    Effects of He implantation on radiation induced segregation (RIS) in Cu-Au and Ni-Si alloys were investigated using in situ Rutherford backscattering spectrometry during simultaneous irradiation with 1.5-MeV He and low-energy (100 or 400-keV) He ions at elevated temperatures. RIS during single He ion irradiation, and the effects of pre-implantation with low-energy He ions, were also studied. RIS near the specimen surface, which was pronounced during 1.5-MeV He single-ion irradiation, was strongly reduced under low-energy He single-ion irradiation, and during simultaneous irradiation with 1.5-MeV He and low-energy He ions. A similar RIS reduction was also observed in the specimens pre-implanted with low-energy He ions. The experimental results indicate that the accumulated He atoms cause the formation of small bubbles, which provide additional recombination sites for freely migrating defects.

  6. Trends in cochlear implants.

    Science.gov (United States)

    Zeng, Fan-Gang

    2004-01-01

    More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic aspects of cochlear implants, focusing on their psychophysical, speech, music, and cognitive performance. This report also forecasts clinical and research trends related to presurgical evaluation, fitting protocols, signal processing, and postsurgical rehabilitation in cochlear implants. Finally, a future landscape in amplification is presented that requires a unique, yet complementary, contribution from hearing aids, middle ear implants, and cochlear implants to achieve a total solution to the entire spectrum of hearing loss treatment and management.

  7. Benefits and Risks of Cochlear Implants

    Science.gov (United States)

    ... and Medical Procedures Implants and Prosthetics Cochlear Implants Benefits and Risks of Cochlear Implants Share Tweet Linkedin ... the Use of Cochlear Implants What are the Benefits of Cochlear Implants? For people with implants: Hearing ...

  8. Optical effects of ion implantation

    International Nuclear Information System (INIS)

    Townsend, P.D.

    1987-01-01

    The review concerns the effects of ion implantation that specifically relate to the optical properties of insulators. Topics which are reviewed include: ion implantation, ion range and damage distributions, colour centre production by ion implantation, high dose ion implantation, and applications for integrated optics. Numerous examples are presented of both diagnostic and industrial examples of ion implantation effects in insulators. (U.K.)

  9. Ion implantation in semiconductors

    International Nuclear Information System (INIS)

    Gusev, V.; Gusevova, M.

    1980-01-01

    The historical development is described of the method of ion implantation, the physical research of the method, its technological solution and practical uses. The method is universally applicable, allows the implantation of arbitrary atoms to an arbitrary material, ensures high purity of the doping element. It is linked with sample processing at low temperatures. In implantation it is possible to independently change the dose and energy of the ions thereby affecting the spatial distribution of the ions. (M.S.)

  10. Ion implantation in semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Gusev, V; Gusevova, M

    1980-06-01

    The historical development of the method of ion implantation, the physical research of the method, its technological solution and practical uses is described. The method is universally applicable, allows the implantation of arbitrary atoms to an arbitrary material and ensures high purity of the doping element. It is linked with sample processing at low temperatures. In implantation it is possible to independently change the dose and energy of the ions thereby affecting the spatial distribution of the ions.

  11. Trends in Cochlear Implants

    OpenAIRE

    Zeng, Fan-Gang

    2004-01-01

    More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic as...

  12. Ion implantation technology

    CERN Document Server

    Downey, DF; Jones, KS; Ryding, G

    1993-01-01

    Ion implantation technology has made a major contribution to the dramatic advances in integrated circuit technology since the early 1970's. The ever-present need for accurate models in ion implanted species will become absolutely vital in the future due to shrinking feature sizes. Successful wide application of ion implantation, as well as exploitation of newly identified opportunities, will require the development of comprehensive implant models. The 141 papers (including 24 invited papers) in this volume address the most recent developments in this field. New structures and possible approach

  13. High energy ion implantation

    International Nuclear Information System (INIS)

    Ziegler, J.F.

    1985-01-01

    High energy ion implantation offers the oppertunity for unique structures in semiconductor processing. The unusual physical properties of such implantations are discussed as well as the special problems in masking and damage annealing. A review is made of proposed circuit structures which involve deep implantation. Examples are: deep buried bipolar collectors fabricated without epitaxy, barrier layers to reduce FET memory sensitivity to soft-fails, CMOS isolation well structures, MeV implantation for customization and correction of completed circuits, and graded reach-throughs to deep active device components. (orig.)

  14. [Silastic implant and synovitis].

    Science.gov (United States)

    Sennwald, G

    1989-07-22

    The silastic implant based on siloxane polymere induces granulomatous synovitis in certain predisposed individuals, a reaction which may continue even after removal of the implant. This is also true of a prosthesis of the trapezium in two of our patients, though to a lesser degree. This is probably the reason why the problem has not yet been widely recognized. The hypothesis is put forward that an enzymatic predisposition may allow chemical degradation of the fragmented silastic implant into a toxic component responsible for the pathologic condition. The slow progression of the lesions is a challenge for the future and puts in question the further use of silastic implants.

  15. Cochlear implant magnet retrofit.

    Science.gov (United States)

    Cohen, N L; Breda, S D; Hoffman, R A

    1988-06-01

    An implantable magnet is now available for patients who have received the standard Nucleus 22-channel cochlear implant and who are not able to wear the headband satisfactorily. This magnet is attached in piggy-back fashion to the previously implanted receiver/stimulator by means of a brief operation under local anesthesia. Two patients have received this magnet retrofit, and are now wearing the headset with greater comfort and satisfaction. It is felt that the availability of this magnet will increase patient compliance in regard to hours of implant usage.

  16. Percutaneous and skeletal biocarbon implants

    Science.gov (United States)

    Mooney, V.

    1977-01-01

    Review of carbon implants developed by NASA discussed four different types of implants and subsequent improvements. Improvements could be of specific interest to rehabilitation centers and similar organizations.

  17. Degradable Implantate: Entwicklungsbeispiele

    Science.gov (United States)

    Ruffieux, Kurt; Wintermantel, Erich

    Resorbierbare Implantate werden seit mehreren Jahrzehnten in der Implantologie eingesetzt. Bekannt wurden diese Biomaterialien mit dem Aufkommen von sich selbst auflösenden Nahtfäden auf der Basis von synthetisch hergestellten Polylactiden und Polyglycoliden in den 70er Jahren. In einem nächsten Schritt wurden Implantate wie Platten und Schrauben zur Gewebefixation aus den gleichen Biomaterialien hergestellt.

  18. Risks of Breast Implants

    Science.gov (United States)

    ... have a risk of developing a type of cancer called breast implant-associated anaplastic large cell lymphoma (BIA-ALCL) in the breast tissue surrounding the implant. BIA-ALCL is not breast cancer. Women diagnosed with BIA-ALCL may need to ...

  19. Ion implantation of metals

    International Nuclear Information System (INIS)

    Dearnaley, G.

    1976-01-01

    In this part of the paper descriptions are given of the effects of ion implantation on (a) friction and wear in metals; and (b) corrosion of metals. In the study of corrosion, ion implantation can be used either to introduce a constituent that is known to convey corrosion resistance, or more generally to examine the parameters which control corrosion. (U.K.)

  20. Ion implantation into diamond

    International Nuclear Information System (INIS)

    Sato, Susumu

    1994-01-01

    The graphitization and the change to amorphous state of diamond surface layer by ion implantation and its characteristics are reported. In the diamond surface, into which more than 10 16 ions/cm 2 was implanted, the diamond crystals are broken, and the structure changes to other carbon structure such as amorphous state or graphite. Accompanying this change of structure, the electric conductivity of the implanted layer shows two discontinuous values due to high resistance and low resistance. This control of structure can be done by the temperature of the base during the ion implantation into diamond. Also it is referred to that by the base temperature during implantation, the mutual change of the structure between amorphous state and graphite can be controlled. The change of the electric resistance and the optical characteristics by the ion implantation into diamond surface, the structural analysis by Raman spectroscopy, and the control of the structure of the implanted layer by the base temperature during implantation are reported. (K.I.)

  1. Number of implants for mandibular implant overdentures: a systematic review

    Science.gov (United States)

    Lee, Jeong-Yol; Kim, Ha-Young; Bryant, S. Ross

    2012-01-01

    PURPOSE The aim of this systematic review is to address treatment outcomes of Mandibular implant overdentures relative to implant survival rate, maintenance and complications, and patient satisfaction. MATERIALS AND METHODS A systematic literature search was conducted by a PubMed search strategy and hand-searching of relevant journals from included studies. Randomized Clinical Trials (RCT) and comparative clinical trial studies on mandibular implant overdentures until August, 2010 were selected. Eleven studies from 1098 studies were finally selected and data were analyzed relative to number of implants. RESULTS Six studies presented the data of the implant survival rate which ranged from 95% to 100% for 2 and 4 implant group and from 81.8% to 96.1% for 1 and 2 implant group. One study, which statistically compared implant survival rate showed no significant differences relative to the number of implants. The most common type of prosthetic maintenance and complications were replacement or reattaching of loose clips for 2 and 4 implant group, and denture repair due to the fracture around an implant for 1 and 2 implant groups. Most studies showed no significant differences in the rate of prosthetic maintenance and complication, and patient satisfaction regardless the number of implants. CONCLUSION The implant survival rate of mandibular overdentures is high regardless of the number of implants. Denture maintenance is likely not inflenced substantially by the number of implants and patient satisfaction is typically high again regardless os the number of implants. PMID:23236572

  2. Ion implantation into iron

    International Nuclear Information System (INIS)

    Iwaki, Masaya

    1978-01-01

    The distribution of implanted ions in iron, the friction characteristics and the corrosion of iron were studied. The distribution of Ni or Cr ions implanted into mild steel was measured. The accelerated voltage was 150 keV, and the beam current density was about 2 microampere/cm 2 . The measurement was made with an ion microanalyzer. The measured distribution was compared with that of LSS theory. Deep invasion of Ni was seen in the measured distribution. The distribution of Cr ions was different from the distribution calculated by the LSS theory. The relative friction coefficient of mild steel varied according to the dose of implanted Cu or N ions, and to the accelerating voltage. Formation of compound metals on the surfaces of metals by ion-implantation was investigated for the purpose to prevent the corrosion of metals. The resistance of mild steel in which Ni ions were implanted was larger than that of mild steel without any treatment. (Kato, T.)

  3. Study of defects, radiation damage and implanted gases in solids by field-ion and atom-probe microscopy

    International Nuclear Information System (INIS)

    Seidman, D.N.; Amano, J.; Wagner, A.

    1980-10-01

    The ability of the field-ion microscope to image individual atoms has been applied, at Cornell University, to the study of fundamental properties of point defects in irradiated or quenched metals. The capability of the atom probe field-ion microscope to determine the chemistry - that is, the mass-to-charge ratio - of a single ion has been used to investigate the behavior of different implanted species in metals. A brief review is presented of: (1) the basic physical principles of the field-ion and atom-probe microscopes; (2) the many applications of these instruments to the study of defects and radiation damage in solids; and (3) the application of the atom-probe field-ion microscope to the study of the behavior of implanted 3 He and 4 He atoms in tungsten. The paper is heavily referenced so that the reader can pursue his specific research interests in detail

  4. Influence of Palatal Coverage and Implant Distribution on Implant Strain in Maxillary Implant Overdentures.

    Science.gov (United States)

    Takahashi, Toshihito; Gonda, Tomoya; Mizuno, Yoko; Fujinami, Yozo; Maeda, Yoshinobu

    2016-01-01

    Maxillary implant overdentures are often used in clinical practice. However, there is no agreement or established guidelines regarding prosthetic design or optimal implant placement configuration. The purpose of this study was to examine the influence of palatal coverage and implant number and distribution in relation to impact strain under maxillary implant overdentures. A maxillary edentulous model with implants and experimental overdentures with and without palatal coverage was fabricated. Four strain gauges were attached to each implant, and they were positioned in the anterior, premolar, and molar areas. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the implant strains were compared using one-way analysis of variance (P = .05). The palatolabial strain was much higher on anterior implants than on other implants in both denture types. Although there was no significant difference between the strain under dentures with and without palatal coverage, palateless dentures tended to result in higher implant strain than dentures with palatal coverage. Dentures supported by only two implants registered higher strain than those supported by four or six implants. Implants under palateless dentures registered higher strain than those under dentures with palatal coverage. Anterior implants exhibited higher palatolabial strain than other implants regardless of palatal coverage and implant configuration; it is therefore recommended that maxillary implant overdentures should be supported by six implants with support extending to the distal end of the arch.

  5. Implants for orthodontic anchorage

    Science.gov (United States)

    Zheng, Xiaowen; Sun, Yannan; Zhang, Yimei; Cai, Ting; Sun, Feng; Lin, Jiuxiang

    2018-01-01

    Abstract Implantanchorage continues to receive much attention as an important orthodontic anchorage. Since the development of orthodontic implants, the scope of applications has continued to increase. Although multiple reviews detailing implants have been published, no comprehensive evaluations have been performed. Thus, the purpose of this study was to comprehensively evaluate the effects of implants based on data published in review articles. An electronic search of the Cochrane Library, Medline, Embase, Ebsco and Sicencedirect for reviews with “orthodontic” and “systematic review or meta analysis” in the title, abstract, keywords, or full text was performed. A subsequent manual search was then performed to identify reviews concerning orthodontic implants. A manual search of the orthodontic journals American Journal of Orthodontics and Dentofacial Orthopedics (AJODO), European Journal of Orthodontics (EJO), and Angle Othodontist was also performed. Such systematic reviews that evaluated the efficacy and safety of orthodontic implants were used to indicate success rates and molar movements. A total of 23 reviews were included in the analysis. The quality of each review was assessed using a measurement tool for Assessment of Multiple Systematic Reviews (AMSTAR), and the review chosen to summarize outcomes had a quality score of >6. Most reviews were less than moderate quality. Success rates of implants ranged in a broad scope, and movement of the maxillary first molar was superior with implants compared with traditional anchorage. PMID:29595673

  6. Maintenance in dental implants

    Directory of Open Access Journals (Sweden)

    Giselle Póvoa Gomes

    2008-01-01

    Full Text Available In implants, maintenance is a decisive factor for obtaining success when implant supported overdentures and dentures are used. The present stud presents, a clinical case of a patient, a 70 year-old white man, with a completely edentulous mandibular alveolar ridge, severe bone resorption with presence of basal bone only, and absence of vestibule. Initially, treatment consisted of the placement of a mandibular overdenture, supported on three implants in the anterior inter-foramen region, as the left implant was transfixed in the basal bone of 2 to 3 millimeters. Eleven years later, another two implants were placed in the anterior area and an immediate load was performed up to the first molars, for the placement of an implant supported fixed. Throughout the entire treatment, meticulous maintenance was carried out, with follow-up for fourteen years, interrupted by the patient’s death. From the third month after the opening the three implants initially placed, the presence of keratinized mucosa, definition of the vestibule, maturation of the alveolar ridge and bone formation in the mento region were observed. It was concluded that good planning, allied to mastery of the technique and adequate maintenance were the prerequisites necessary for obtaining favorable results, success of the present case, and for the patient to have a better quality of life.

  7. Nanotechnology for dental implants.

    Science.gov (United States)

    Tomsia, Antoni P; Lee, Janice S; Wegst, Ulrike G K; Saiz, Eduardo

    2013-01-01

    With the advent of nanotechnology, an opportunity exists for the engineering of new dental implant materials. Metallic dental implants have been successfully used for decades, but they have shortcomings related to osseointegration and mechanical properties that do not match those of bone. Absent the development of an entirely new class of materials, faster osseointegration of currently available dental implants can be accomplished by various surface modifications. To date, there is no consensus regarding the preferred method(s) of implant surface modification, and further development will be required before the ideal implant surface can be created, let alone become available for clinical use. Current approaches can generally be categorized into three areas: ceramic coatings, surface functionalization, and patterning on the micro- to nanoscale. The distinctions among these are imprecise, as some or all of these approaches can be combined to improve in vivo implant performance. These surface improvements have resulted in durable implants with a high percentage of success and long-term function. Nanotechnology has provided another set of opportunities for the manipulation of implant surfaces in its capacity to mimic the surface topography formed by extracellular matrix components of natural tissue. The possibilities introduced by nanotechnology now permit the tailoring of implant chemistry and structure with an unprecedented degree of control. For the first time, tools are available that can be used to manipulate the physicochemical environment and monitor key cellular events at the molecular level. These new tools and capabilities will result in faster bone formation, reduced healing time, and rapid recovery to function.

  8. Ion implantation for microelectronics

    International Nuclear Information System (INIS)

    Dearnaley, G.

    1977-01-01

    Ion implantation has proved to be a versatile and efficient means of producing microelectronic devices. This review summarizes the relevant physics and technology and assesses the advantages of the method. Examples are then given of widely different device structures which have been made by ion implantation. While most of the industrial application has been in silicon, good progress continues to be made in the more difficult field of compound semiconductors. Equipment designed for the industrial ion implantation of microelectronic devices is discussed briefly. (Auth.)

  9. Optimization of dental implantation

    Science.gov (United States)

    Dol, Aleksandr V.; Ivanov, Dmitriy V.

    2017-02-01

    Modern dentistry can not exist without dental implantation. This work is devoted to study of the "bone-implant" system and to optimization of dental prostheses installation. Modern non-invasive methods such as MRI an 3D-scanning as well as numerical calculations and 3D-prototyping allow to optimize all of stages of dental prosthetics. An integrated approach to the planning of implant surgery can significantly reduce the risk of complications in the first few days after treatment, and throughout the period of operation of the prosthesis.

  10. Improving the SMM and luminescence properties of lanthanide complexes with LnO9 cores in the presence of ZnII: an emissive Zn2Dy single ion magnet.

    Science.gov (United States)

    Fondo, Matilde; Corredoira-Vázquez, Julio; Herrera-Lanzós, Antía; García-Deibe, Ana M; Sanmartín-Matalobos, Jesús; Herrera, Juan Manuel; Colacio, Enrique; Nuñez, Cristina

    2017-12-12

    Mononuclear complexes of stoichiometry [Ln(H 3 L)(H 2 O)(NO 3 )](NO 3 ) 2 (Ln = Tb, 1; Dy, 2, Er, 3), which crystallise with different solvates, and the heterotrinuclear compound [Zn 2 Dy(L)(NO 3 ) 3 (OH)] (4) can be obtained with the same H 3 L compartmental ligand. The single X-ray crystal structure of the mononuclear complexes shows a LnO 9 core with a muffin-like disposition while the geometry of the DyO 9 core in 4 seems to be closer to spherical capped square antiprism. The analysis of the magnetic properties of all the complexes demonstrates that the mononuclear lanthanide compounds do not show slow relaxation of the magnetization, even when the samples are diluted with a diamagnetic matrix and subjected to a dc applied field of 1000 Oe. Nevertheless, the heterotrinuclear dysprosium complex 4·3H 2 O is a field-induced single ion magnet, with an estimated U eff barrier of 59 K. The luminescence characterisation of all the metal complexes in methanol solution at 298 K also shows a notable increase in the fluorescence emission of the heterotrinuclear complex with respect to the mononuclear ones, in such a way that 4 can be defined as a fluorescent single ion magnet.

  11. Examination of the ion-implantation route to fabrication of the Kane quantum computer using advanced imaging techniques

    International Nuclear Information System (INIS)

    Pakes, C.; Millar, V.; Peng, J.; Cimmino, A.; Prawer, S.; Jamieson, D.; Yang, C.; McKinnon, R.; Stanley, F.; Clark, R.; University of New South Wales, NSW; Dzurak, A.

    2002-01-01

    Full text: The Kane solid-state quantum computer employs as qubits an array of 31 P atoms embedded with nanoscale precision in a silicon matrix. One proposal for the fabrication of such an array is by phosphorous-ion implantation. We present an overview of a program of research aiming to develop advanced imaging techniques to address key issues relating to the fabrication of the Kane device by ion implantation, focusing particularly on the development of surface-resist technology to allow the registration of single implanted ions and an examination of the extent of damage imposed on the silicon matrix. Our surface resists take the form of a polymethylmethacrylate (PMMA) thin-films, which have been exposed both to MeV and keV ions. Registration of ion implantation is based on the development of localised chemical modification arising from latent damage caused within the PMMA layer by the passage of an implanted ion. On development of the resist, atomic force microscopy imaging demonstrates the formation of clearly defined etched holes, of typical diameter 30 nm, which are ascribed to single-ion impacts. The use of novel scanning probes, such as carbon nanotubes, for imaging complex PMMA resist structures will be illustrated. Potential applications to the fabrication of self-aligned gate structures will be discussed

  12. Breast Reconstruction with Implants

    Science.gov (United States)

    ... your surgical options and discuss the advantages and disadvantages of implant-based reconstruction, and may show you ... Policy Notice of Privacy Practices Notice of Nondiscrimination Advertising Mayo Clinic is a not-for-profit organization ...

  13. Ion Implantation of Polymers

    DEFF Research Database (Denmark)

    Popok, Vladimir

    2012-01-01

    The current paper presents a state-of-the-art review in the field of ion implantation of polymers. Numerous published studies of polymers modified by ion beams are analysed. General aspects of ion stopping, latent track formation and changes of structure and composition of organic materials...... are discussed. Related to that, the effects of radiothermolysis, degassing and carbonisation are considered. Specificity of depth distributions of implanted into polymers impurities is analysed and the case of high-fluence implantation is emphasised. Within rather broad topic of ion bombardment, the focus...... is put on the low-energy implantation of metal ions causing the nucleation and growth of nanoparticles in the shallow polymer layers. Electrical, optical and magnetic properties of metal/polymer composites are under the discussion and the approaches towards practical applications are overviewed....

  14. Precipitation processes in implanted materials

    International Nuclear Information System (INIS)

    Borders, J.A.

    1978-01-01

    Ion implantation is a nonequilibrium process. It is possible to implant materials with impurities to concentration levels which exceed the solid solubilities. The return of the system to thermodynamic equilibrium is often accomplished by precipitation of the implanted species or a compound involving atoms of both the host and the implanted species. This may involve long time scales when taking place at room temperature or it may take place during the implantation

  15. Ion implantation for semiconductors

    International Nuclear Information System (INIS)

    Grey-Morgan, T.

    1995-01-01

    Full text: Over the past two decades, thousands of particle accelerators have been used to implant foreign atoms like boron, phosphorus and arsenic into silicon crystal wafers to produce special embedded layers for manufacturing semiconductor devices. Depending on the device required, the atomic species, the depth of implant and doping levels are the main parameters for the implantation process; the selection and parameter control is totally automated. The depth of the implant, usually less than 1 micron, is determined by the ion energy, which can be varied between 2 and 600 keV. The ion beam is extracted from a Freeman or Bernas type ion source and accelerated to 60 keV before mass analysis. For higher beam energies postacceleration is applied up to 200 keV and even higher energies can be achieved by mass selecting multiplycharged ions, but with a corresponding reduction in beam output. Depending on the device to be manufactured, doping levels can range from 10 10 to 10 15 atoms/cm 2 and are controlled by implanter beam currents in the range up to 30mA; continuous process monitoring ensures uniformity across the wafer of better than 1 % . As semiconductor devices get smaller, additional sophistication is required in the design of the implanter. The silicon wafers charge electrically during implantation and this charge must be dissipated continuously to reduce the electrical stress in the device and avoid destructive electrical breakdown. Electron flood guns produce low energy electrons (below 10 electronvolts) to neutralize positive charge buildup and implanter design must ensure minimum contamination by other isotopic species and ensure low internal sputter rates. The pace of technology in the semiconductor industry is such that implanters are being built now for 256 Megabit circuits but which are only likely to be widely available five years from now. Several specialist companies manufacture implanter systems, each costing around US$5 million, depending on the

  16. Quantitative ion implantation

    International Nuclear Information System (INIS)

    Gries, W.H.

    1976-06-01

    This is a report of the study of the implantation of heavy ions at medium keV-energies into electrically conducting mono-elemental solids, at ion doses too small to cause significant loss of the implanted ions by resputtering. The study has been undertaken to investigate the possibility of accurate portioning of matter in submicrogram quantities, with some specific applications in mind. The problem is extensively investigated both on a theoretical level and in practice. A mathematical model is developed for calculating the loss of implanted ions by resputtering as a function of the implanted ion dose and the sputtering yield. Numerical data are produced therefrom which permit a good order-of-magnitude estimate of the loss for any ion/solid combination in which the ions are heavier than the solid atoms, and for any ion energy from 10 to 300 keV. The implanted ion dose is measured by integration of the ion beam current, and equipment and techniques are described which make possible the accurate integration of an ion current in an electromagnetic isotope separator. The methods are applied to two sample cases, one being a stable isotope, the other a radioisotope. In both cases independent methods are used to show that the implantation is indeed quantitative, as predicted. At the same time the sample cases are used to demonstrate two possible applications for quantitative ion implantation, viz. firstly for the manufacture of calibration standards for instrumental micromethods of elemental trace analysis in metals, and secondly for the determination of the half-lives of long-lived radioisotopes by a specific activity method. It is concluded that the present study has advanced quantitative ion implantation to the state where it can be successfully applied to the solution of problems in other fields

  17. Ion implantation - an introduction

    International Nuclear Information System (INIS)

    Townsend, P.D.

    1986-01-01

    Ion implantation is a widely used technique with a literature that covers semiconductor production, surface treatments of steels, corrosion resistance, catalysis and integrated optics. This brief introduction outlines advantages of the technique, some aspects of the underlying physics and examples of current applications. Ion implantation is already an essential part of semiconductor technology while in many other areas it is still in an early stage of development. The future scope of the subject is discussed. (author)

  18. Contraceptive implants: current perspectives

    Directory of Open Access Journals (Sweden)

    Rowlands S

    2014-09-01

    Full Text Available Sam Rowlands,1,2 Stephen Searle3 1Centre of Postgraduate Medical Research and Education, School of Health and Social Care, Bournemouth University, Bournemouth, United Kingdom; 2Dorset HealthCare, Bournemouth, United Kingdom; 3Sexual Health Services, Chesterfield, United KingdomAbstract: Progestin-only contraceptive implants are a highly cost-effective form of long-acting reversible contraception. They are the most effective reversible contraceptives and are of a similar effectiveness to sterilization. Pregnancies are rare in women using this method of contraception, and those that do occur must be fully investigated, with an ultrasound scan of the arm and serum etonogestrel level if the implant cannot be located. There are very few contraindications to use of implants, and they have an excellent safety profile. Both acceptability and continuation with the method are high. Noncontraceptive benefits include improvements in dysmenorrhea, ovulatory pain, and endometriosis. Problematic bleeding is a relatively common adverse effect that must be covered in preinsertion information-giving and supported adequately if it occurs. Recognized training for both insertion and removal should be undertaken. Care needs to be taken at both insertion and removal to avoid neurovascular injury. Implants should always be palpable; if they are not, noninsertion should be assumed until disproven. Etonogestrel implants are now radiopaque, which aids localization. Anticipated difficult removals should be performed by specially trained experts. Keywords: contraceptive, subdermal implant, etonogestrel, levonorgestrel, progestin-only, long-acting reversible contraception

  19. Anodized dental implant surface

    Directory of Open Access Journals (Sweden)

    Sunil Kumar Mishra

    2017-01-01

    Full Text Available Purpose: Anodized implants with moderately rough surface were introduced around 2000. Whether these implants enhanced biologic effect to improve the environment for better osseointegration was unclear. The purpose of this article was to review the literature available on anodized surface in terms of their clinical success rate and bone response in patients till now. Materials and Methods: A broad electronic search of MEDLINE and PubMed databases was performed. A focus was made on peer-reviewed dental journals. Only articles related to anodized implants were included. Both animal and human studies were included. Results: The initial search of articles resulted in 581 articles on anodized implants. The initial screening of titles and abstracts resulted in 112 full-text papers; 40 animal studies, 16 studies on cell adhesion and bacterial adhesion onto anodized surfaced implants, and 47 human studies were included. Nine studies, which do not fulfill the inclusion criteria, were excluded. Conclusions: The long-term studies on anodized surface implants do favor the surface, but in most of the studies, anodized surface is compared with that of machined surface, but not with other surfaces commercially available. Anodized surface in terms of clinical success rate in cases of compromised bone and immediately extracted sockets has shown favorable success.

  20. Plasma source ion implantation

    International Nuclear Information System (INIS)

    Conrad, J.R.; Forest, C.

    1986-01-01

    The authors' technique allows the ion implantation to be performed directly within the ion source at higher currents without ion beam extraction and transport. The potential benefits include greatly increased production rates (factors of 10-1000) and the ability to implant non-planar targets without rastering or shadowing. The technique eliminates the ion extractor grid set, beam raster equipment, drift space and target manipulator equipment. The target to be implanted is placed directly within the plasma source and is biased to a large negative potential so that plasma ions gain energy as they accelerate through the potential drop across the sheath that forms at the plasma boundary. Because the sheath surrounds the target on all sides, all surfaces of the target are implanted without the necessity to raster the beam or to rotate the target. The authors have succeeded in implanting nitrogen ions in a silicon target to the depths and concentrations required for surface treatment of materials like stainless steel and titanium alloys. They have performed ESCA measurements of the penetration depth profile of a silicon target that was biased to 30 kV in a nitrogen discharge plasma. Nitrogen ions were implanted to a depth of 700A at a peak concentration of 30% atomic. The measured profile is quite similar to a previously obtained profile in titanium targets with conventional techniques

  1. Influence of welded boundaries in anelastic media on energy flow, and characteristics of P, S-I, and S-II waves: Observational evidence for inhomogeneous body waves in low-loss solids

    Science.gov (United States)

    Borcherdt, Roger D.; Glassmoyer, Gary; Wennerberg, Leif

    1986-10-01

    A general computer code, developed to calculate anelastic reflection-refraction coefficients, energy flow, and the physical characteristics for general P, S-I, and S-II waves, quantitatively describes physical characteristics for wave fields in anelastic media that do not exist in elastic media. Consideration of wave fields incident on boundaries between anelastic media shows that scattered wave fields experience reductions in phase and energy speeds, increases in maximum attenuation and Q-1, and directions of maximum energy flow distinct from phase propagation. Each of these changes in physical characteristics are shown to vary with angle of incidence. Finite relaxation times for anelastic media result in energy flow due to interaction of superimposed radiation fields and contribute to energy flow across anelastic boundaries for all angles of incidence. Agreement of theoretical and numerical results with laboratory measurements argues for the validity of the theoretical and numerical formulations incorporating inhomogeneous wave fields. The agreement attests to the applicability of the model and helps confirm the existence of inhomogeneous body waves and their associated set of distinct physical characteristics in the earth. The existence of such body waves in layered, low-loss anelastic solids implies the need to reformulate some seismological models of the earth. The exact anelastic formulation for a liquid-solid interface with no low-loss approximations predicts the existence of a range of angles of incidence or an anelastic Rayleigh window, through which significant amounts of energy are transmitted across the boundary. The window accounts for the discrepancy apparent between measured reflection data presented in early textbooks and predictions based on classical elasticity theory. Characteristics of the anelastic Rayleigh window are expected to be evident in certain sets of wide-angle, ocean-bottom reflection data and to be useful in estimating Q-1 for some

  2. Short dental implants: an emerging concept in implant treatment.

    Science.gov (United States)

    Al-Hashedi, Ashwaq Ali; Taiyeb Ali, Tara Bai; Yunus, Norsiah

    2014-06-01

    Short implants have been advocated as a treatment option in many clinical situations where the use of conventional implants is limited. This review outlines the effectiveness and clinical outcomes of using short implants as a valid treatment option in the rehabilitation of edentulous atrophic alveolar ridges. Initially, an electronic search was performed on the following databases: Medline, PubMed, Embase, Cochrane Database of Systematic Reviews, and DARE using key words from January 1990 until May 2012. An additional hand search was included for the relevant articles in the following journals: International Journal of Oral and Maxillofacial Implants, Clinical Oral Implants Research, Journal of Clinical Periodontology, International Journal of Periodontics, Journal of Periodontology, and Clinical Implant Dentistry and Related Research. Any relevant papers from the journals' references were hand searched. Articles were included if they provided detailed data on implant length, reported survival rates, mentioned measures for implant failure, were in the English language, involved human subjects, and researched implants inserted in healed atrophic ridges with a follow-up period of at least 1 year after implant-prosthesis loading. Short implants demonstrated a high rate of success in the replacement of missing teeth in especially atrophic alveolar ridges. The advanced technology and improvement of the implant surfaces have encouraged the success of short implants to a comparable level to that of standard implants. However, further randomized controlled clinical trials and prospective studies with longer follow-up periods are needed.

  3. Comparison of single and mixed ion implantation effects on the changes of the surface hardness, light transmittance, and electrical conductivity of polymeric materials

    International Nuclear Information System (INIS)

    Park, J. W.; Lee, J. H.; Lee, J. S.; Kil, J. G.; Choi, B. H.; Han, Z. H.

    2001-01-01

    Single or mixed ions of N, He, C were implanted onto the transparent PET(Polyethylen Terephtalate) with the ion energies of less than 100 keV and the surface hardness, light transmittance and electrical conductivity were examined. As measured with nanoindentation, mixed ion implantations such as N + +He + or N + + C + exhibited more increase in the surface hardness than the single ion implantation. Especially, implantation of C+N ions increased the surface hardness by about three times as compared to the implantation of N ion alone, which means more than 10 times increase than the untreated PET. Surface electrical conductivity was increased along with the hardness increase. The conductivity increase was more proportional to the hardness when used the higher ion energy and ion dose, while it did not show any relationship at as low as 50 keV of ion energy. The light at the 550 nm wavelength (visual range) transmitted more than 85%, which is close to that of as-received PET, and at the wavelength below 300 nm(UV range) the rays were absorbed more than 95% as traveling through the sheet, implying that there are processing parameters which the ion implanted PET maintains the transparency and absorbs the UV rays

  4. [Bilateral cochlear implants].

    Science.gov (United States)

    Müller, J

    2017-07-01

    Cochlear implants (CI) are standard for the hearing rehabilitation of severe to profound deafness. Nowadays, if bilaterally indicated, bilateral implantation is usually recommended (in accordance with German guidelines). Bilateral implantation enables better speech discrimination in quiet and in noise, and restores directional and spatial hearing. Children with bilateral CI are able to undergo hearing-based hearing and speech development. Within the scope of their individual possibilities, bilaterally implanted children develop faster than children with unilateral CI and attain, e.g., a larger vocabulary within a certain time interval. Only bilateral implantation allows "binaural hearing," with all the benefits that people with normal hearing profit from, namely: better speech discrimination in quiet and in noise, as well as directional and spatial hearing. Naturally, the developments take time. Binaural CI users benefit from the same effects as normal hearing persons: head shadow effect, squelch effect, and summation and redundancy effects. Sequential CI fitting is not necessarily disadvantageous-both simultaneously and sequentially fitted patients benefit in a similar way. For children, earliest possible fitting and shortest possible interval between the two surgeries seems to positively influence the outcome if bilateral CI are indicated.

  5. Psychological intervention following implantation of an implantable defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van den Broek, Krista C; Sears, Samuel F

    2007-01-01

    The medical benefits of the implantable cardioverter defibrillator (ICD) are unequivocal, but a subgroup of patients experiences emotional difficulties following implantation. For this subgroup, some form of psychological intervention may be warranted. This review provides an overview of current ...

  6. Management of peri-implantitis

    Directory of Open Access Journals (Sweden)

    Jayachandran Prathapachandran

    2012-01-01

    Full Text Available Peri-implantitis is a site-specific infectious disease that causes an inflammatory process in soft tissues, and bone loss around an osseointegrated implant in function. The etiology of the implant infection is conditioned by the status of the tissue surrounding the implant, implant design, degree of roughness, external morphology, and excessive mechanical load. The microorganisms most commonly associated with implant failure are spirochetes and mobile forms of Gram-negative anaerobes, unless the origin is the result of simple mechanical overload. Diagnosis is based on changes of color in the gingiva, bleeding and probing depth of peri-implant pockets, suppuration, X-ray, and gradual loss of bone height around the tooth. Treatment will differ depending upon whether it is a case of peri-implant mucositis or peri-implantitis. The management of implant infection should be focused on the control of infection, the detoxification of the implant surface, and regeneration of the alveolar bone. This review article deals with the various treatment options in the management of peri-implantitis. The article also gives a brief description of the etiopathogenesis, clinical features, and diagnosis of peri-implantitis.

  7. Quantum criticality of a spin-1 XY model with easy-plane single-ion anisotropy via a two-time Green function approach avoiding the Anderson-Callen decoupling

    Science.gov (United States)

    Mercaldo, M. T.; Rabuffo, I.; De Cesare, L.; Caramico D'Auria, A.

    2016-04-01

    In this work we study the quantum phase transition, the phase diagram and the quantum criticality induced by the easy-plane single-ion anisotropy in a d-dimensional quantum spin-1 XY model in absence of an external longitudinal magnetic field. We employ the two-time Green function method by avoiding the Anderson-Callen decoupling of spin operators at the same sites which is of doubtful accuracy. Following the original Devlin procedure we treat exactly the higher order single-site anisotropy Green functions and use Tyablikov-like decouplings for the exchange higher order ones. The related self-consistent equations appear suitable for an analysis of the thermodynamic properties at and around second order phase transition points. Remarkably, the equivalence between the microscopic spin model and the continuous O(2) -vector model with transverse-Ising model (TIM)-like dynamics, characterized by a dynamic critical exponent z=1, emerges at low temperatures close to the quantum critical point with the single-ion anisotropy parameter D as the non-thermal control parameter. The zero-temperature critic anisotropy parameter Dc is obtained for dimensionalities d > 1 as a function of the microscopic exchange coupling parameter and the related numerical data for different lattices are found to be in reasonable agreement with those obtained by means of alternative analytical and numerical methods. For d > 2, and in particular for d=3, we determine the finite-temperature critical line ending in the quantum critical point and the related TIM-like shift exponent, consistently with recent renormalization group predictions. The main crossover lines between different asymptotic regimes around the quantum critical point are also estimated providing a global phase diagram and a quantum criticality very similar to the conventional ones.

  8. Ion implantation control system

    International Nuclear Information System (INIS)

    Gault, R. B.; Keutzer, L. L.

    1985-01-01

    A control system is disclosed for an ion implantation system of the type in which the wafers to be implanted are mounted around the periphery of a disk which rotates and also moves in a radial direction relative to an ion beam to expose successive sections of each wafer to the radiation. The control system senses beam current which passes through one or more apertures in the disk and is collected by a Faraday cup. This current is integrated to obtain a measure of charge which is compared with a calculated value based upon the desired ion dosage and other parameters. The resultant controls the number of incremental steps the rotating disk moves radially to expose the adjacent sections of each wafer. This process is continued usually with two or more traverses until the entire surface of each wafer has been implanted with the proper ion dosage

  9. Implantation for tribological applications

    International Nuclear Information System (INIS)

    Leutenecker, R.; Cao-Minh, U.; Overbeck, R.

    1992-08-01

    Empirical results on the strength enhancement of steels by N- and B-implantation should be explained from a materials science point of view. The methods applied were X-ray diffractometry and element depth profiling. The investigations of N-implanted steels focussed on the nitride formation in selected model materials and, with respect to applications, in: X90 CrMoV and S 6-5-2 tool steels, austenite X10 CrNiTi189 as well as in hard chromium plates. Main topic in B-implanted steels were the transformations: crystalline Fe-phase - amorphous Fe-B-phase - crystalline boride phases. The result is an improvement in process control by first an insight into the strength enhancing mechanisms and second in into their generation depending on the materials microstructure and the process parameter. (orig.). 101 figs., 16 tabs., 15 refs [de

  10. Dental implants: A review.

    Science.gov (United States)

    Guillaume, B

    2016-12-01

    A high number of patients have one or more missing tooth and it is estimated that one in four American subjects over the age of 74 have lost all their natural teeth. Many options exist to replace missing teeth but dental implants have become one of the most used biomaterial to replace one (or more) missing tooth over the last decades. Contemporary dental implants made with titanium have been proven safe and effective in large series of patients. This review considers the main historical facts concerned with dental implants and present the different critical factors that will ensure a good osseo-integration that will ensure a stable prosthesis anchorage. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  11. Tribology of implantation bilayers

    International Nuclear Information System (INIS)

    Pivin, J.C.

    1989-01-01

    The mechanical behaviour of implantation films must be analysed in terms of bilayer rheology (laws of mechanical behaviour). Tribology takes into account thermodynamical, chemical and metallurgical parameters to interpret the friction properties of a system as a whole. One can distinguish between alloying effects of ion implantation and structural modifications. Alloying affects the basic properties of the crystal: elasticity, cohesion, mobility of planar defects, and its surface electronic structure, which determines the reactivity with the atmosphere or the friction counterpart (adhesion). Radiation damage and phase changes act more particularly on the modes of gliding and climbing of dislocations, and fracture mechanisms. 105 refs.; 11 figs.; 1 table

  12. [Tinnitus and implants].

    Science.gov (United States)

    Despreaux, G; Tison, P; Van Den Abbeele, T; Moine, A; Frachet, B

    1990-01-01

    The experience with cochlear implantation at Avicenne hospital prompted us to carry out a retrospective study on tinnitus in a population of operated patients. Improvement or disappearance of the symptoms was noted in all cases. These results, which partly match those found in the literature, are probably produced by rehabilitation inhibiting the "deafferentation" mechanisms in analogy with pain phenomena. In some precise cases, which are described, they led us to proposing implantation even though the main, if not sole, complaint of the patient was tinnitus.

  13. Recent advances in dental implants.

    Science.gov (United States)

    Hong, Do Gia Khang; Oh, Ji-Hyeon

    2017-12-01

    Dental implants are a common treatment for the loss of teeth. This paper summarizes current knowledge on implant surfaces, immediate loading versus conventional loading, short implants, sinus lifting, and custom implants using three-dimensional printing. Most of the implant surface modifications showed good osseointegration results. Regarding biomolecular coatings, which have been recently developed and studied, good results were observed in animal experiments. Immediate loading had similar clinical outcomes compared to conventional loading and can be used as a successful treatment because it has the advantage of reducing treatment times and providing early function and aesthetics. Short implants showed similar clinical outcomes compared to standard implants. A variety of sinus augmentation techniques, grafting materials, and alternative techniques, such as tilted implants, zygomatic implants, and short implants, can be used. With the development of new technologies in three-dimension and computer-aided design/computer-aided manufacturing (CAD/CAM) customized implants can be used as an alternative to conventional implant designs. However, there are limitations due to the lack of long-term studies or clinical studies. A long-term clinical trial and a more predictive study are needed.

  14. Untreated silicone breast implant rupture

    DEFF Research Database (Denmark)

    Hölmich, Lisbet R; Vejborg, Ilse M; Conrad, Carsten

    2004-01-01

    Implant rupture is a well-known complication of breast implant surgery that can pass unnoticed by both patient and physician. To date, no prospective study has addressed the possible health implications of silicone breast implant rupture. The aim of the present study was to evaluate whether untre...

  15. "Kas siis selle maa keel..." / Ela Tomson

    Index Scriptorium Estoniae

    Tomson, Ela, 1945-

    2003-01-01

    Tähelepanekuid Brüsselis Euroopa Komisjoni korraldusel toimunud rahvusvaheliselt seminarilt, kus käsitleti vähemuskeelte staatust EL-i liikmes- ja liituvates riikides. Autori sõnul on Euroopas Eesti suhtes varasemast oluliselt rohkem mõistmist

  16. Kui sind ei ole siin, siis...

    Index Scriptorium Estoniae

    Käesel, Tiina, 1943-

    2010-01-01

    Münchenis 62. rahvusvahelise käsitöömessi raames toimunud rahvusvahelisest konkurssnäitusest "Ehe" (Schmuck"), kuhu Eestist oli valitud Tanel Veenre tööga "Flora talv", konkurssnäitusest "Talendid" ("Talente"), Eesti ehtekunstnike rühmituse ÕhuLoss näitusest Müncheni Vana põhjakalmistu surnuaiavahi majas jt. ehtenäitustest

  17. Mis on siis see Solaris? / Ike Volkov

    Index Scriptorium Estoniae

    Volkov, Ike, 1951-

    2009-01-01

    Tallinna kesklinnas avatud meelelahutus- ja elustiilikeskusest Solaris. Arhitekt Raivo Puusepp. Lühidalt 2004. a. toimunud keskuse avalikust arhitektuurikonkursist, mille võitis Arhitektuuriagentuur. Uue Sakala keskuse (Solarise) eskiisprojekti läbivaatamistest ja aruteludest linnaplaneerimise ametis, arvamustest ja tehtud ettepanekutest

  18. Two-stage implant systems.

    Science.gov (United States)

    Fritz, M E

    1999-06-01

    Since the advent of osseointegration approximately 20 years ago, there has been a great deal of scientific data developed on two-stage integrated implant systems. Although these implants were originally designed primarily for fixed prostheses in the mandibular arch, they have been used in partially dentate patients, in patients needing overdentures, and in single-tooth restorations. In addition, this implant system has been placed in extraction sites, in bone-grafted areas, and in maxillary sinus elevations. Often, the documentation of these procedures has lagged. In addition, most of the reports use survival criteria to describe results, often providing overly optimistic data. It can be said that the literature describes a true adhesion of the epithelium to the implant similar to adhesion to teeth, that two-stage implants appear to have direct contact somewhere between 50% and 70% of the implant surface, that the microbial flora of the two-stage implant system closely resembles that of the natural tooth, and that the microbiology of periodontitis appears to be closely related to peri-implantitis. In evaluations of the data from implant placement in all of the above-noted situations by means of meta-analysis, it appears that there is a strong case that two-stage dental implants are successful, usually showing a confidence interval of over 90%. It also appears that the mandibular implants are more successful than maxillary implants. Studies also show that overdenture therapy is valid, and that single-tooth implants and implants placed in partially dentate mouths have a success rate that is quite good, although not quite as high as in the fully edentulous dentition. It would also appear that the potential causes of failure in the two-stage dental implant systems are peri-implantitis, placement of implants in poor-quality bone, and improper loading of implants. There are now data addressing modifications of the implant surface to alter the percentage of

  19. Semiconductor Ion Implanters

    International Nuclear Information System (INIS)

    MacKinnon, Barry A.; Ruffell, John P.

    2011-01-01

    In 1953 the Raytheon CK722 transistor was priced at $7.60. Based upon this, an Intel Xeon Quad Core processor containing 820,000,000 transistors should list at $6.2 billion! Particle accelerator technology plays an important part in the remarkable story of why that Intel product can be purchased today for a few hundred dollars. Most people of the mid twentieth century would be astonished at the ubiquity of semiconductors in the products we now buy and use every day. Though relatively expensive in the nineteen fifties they now exist in a wide range of items from high-end multicore microprocessors like the Intel product to disposable items containing 'only' hundreds or thousands like RFID chips and talking greeting cards. This historical development has been fueled by continuous advancement of the several individual technologies involved in the production of semiconductor devices including Ion Implantation and the charged particle beamlines at the heart of implant machines. In the course of its 40 year development, the worldwide implanter industry has reached annual sales levels around $2B, installed thousands of dedicated machines and directly employs thousands of workers. It represents in all these measures, as much and possibly more than any other industrial application of particle accelerator technology. This presentation discusses the history of implanter development. It touches on some of the people involved and on some of the developmental changes and challenges imposed as the requirements of the semiconductor industry evolved.

  20. Implantable enzyme amperometric biosensors.

    Science.gov (United States)

    Kotanen, Christian N; Moussy, Francis Gabriel; Carrara, Sandro; Guiseppi-Elie, Anthony

    2012-05-15

    The implantable enzyme amperometric biosensor continues as the dominant in vivo format for the detection, monitoring and reporting of biochemical analytes related to a wide range of pathologies. Widely used in animal studies, there is increasing emphasis on their use in diabetes care and management, the management of trauma-associated hemorrhage and in critical care monitoring by intensivists in the ICU. These frontier opportunities demand continuous indwelling performance for up to several years, well in excess of the currently approved seven days. This review outlines the many challenges to successful deployment of chronically implantable amperometric enzyme biosensors and emphasizes the emerging technological approaches in their continued development. The foreign body response plays a prominent role in implantable biotransducer failure. Topics considering the approaches to mitigate the inflammatory response, use of biomimetic chemistries, nanostructured topographies, drug eluting constructs, and tissue-to-device interface modulus matching are reviewed. Similarly, factors that influence biotransducer performance such as enzyme stability, substrate interference, mediator selection and calibration are reviewed. For the biosensor system, the opportunities and challenges of integration, guided by footprint requirements, the limitations of mixed signal electronics, and power requirements, has produced three systems approaches. The potential is great. However, integration along the multiple length scales needed to address fundamental issues and integration across the diverse disciplines needed to achieve success of these highly integrated systems, continues to be a challenge in the development and deployment of implantable amperometric enzyme biosensor systems. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. HA-Coated Implant

    DEFF Research Database (Denmark)

    Daugaard, Henrik; Søballe, Kjeld; Bechtold, Joan E

    2014-01-01

    of improving the fixation of implants. Of these, hydroxyapatite (HA) is the most widely used and most extensively investigated. HA is highly osseoconductive, and the positive effect is well documented in both basic and long-term clinical research [1–6]. This chapter describes experimental and clinical studies...

  2. Middle ear implants

    Directory of Open Access Journals (Sweden)

    K S Gangadhara Somayaji

    2013-01-01

    Full Text Available Hearing loss is becoming more common in the society living in cities with lot of background noise around, and frequent use of gadgets like mobile phones, MP3s, and IPods are adding to the problem. The loss may involve the conductive or perceptive pathway. Majority of the patients with conductive hearing loss will revert back to normal hearing levels with medical and/or surgical treatment. However, in sensorineural hearing loss, many factors are involved in the management. Though traditionally hearing aids in various forms are the most commonly used modality in managing these patients, there are some drawbacks associated with them. Implantable middle ear amplifiers represent the most recent breakthrough in the management of hearing loss. Middle ear implants are surgically implanted electronic devices that aim to correct hearing loss by stimulating the ossicular chain or middle ear. Of late, they are also being used in the management of congenital conductive hearing loss and certain cases of chronic otitis media with residual hearing loss. The article aims to provide general information about the technology, indications and contraindications, selection of candidates, available systems, and advantages of middle ear implants. (MEI

  3. Delayed breast implant reconstruction

    DEFF Research Database (Denmark)

    Hvilsom, Gitte B.; Hölmich, Lisbet R.; Steding-Jessen, Marianne

    2011-01-01

    the period 1999 to 2006; 239 one-stage procedures and 353 two-stage procedures. The postoperative course through November 2009 was evaluated by cumulative incidence adjusting for competing risks for the selected outcomes; hematoma, infection, seroma, implant rupture, severe capsular contracture (modified...

  4. Remote actuated valve implant

    Science.gov (United States)

    McKnight, Timothy E; Johnson, Anthony; Moise, Jr., Kenneth J; Ericson, Milton Nance; Baba, Justin S; Wilgen, John B; Evans, III, Boyd McCutchen

    2014-02-25

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  5. Preferential solvation of single ions in mixed solvents: Part 1. New experimental approach and solvation of monovalent ions in methanol-water and acetonitrile-water mixture. Part 2. Theoretical computation and comparison with experimental data

    International Nuclear Information System (INIS)

    Rege, Aarti C.; Venkataramani, B.; Gupta, A.R.

    1999-06-01

    Preferential solvation of single ion solutions has been studied with Li + , Na + , K + and Ag +- forms of Dowex 50W resins of different cross-linkings in methanol-water and acetonitrile (AN)- water mixtures. The solvent uptake by this alkali metal ionic forms of Dowex 50W resins was studied in an isopiestic set-up using 2,4,6 and 8 m LiCl solutions in 11.0, 20.8, 44.3 and 70.2 % (w/w) methanol-water mixtures and that of Na +- and Ag +- forms using 14.6 to 94.3 % (w/w) AN - water mixtures. The solvent sorbed in the resin phase was extracted by Rayleigh-type distillation and analysed gas chromatographically. The data were analysed by the N s (mole fraction of the organic solvent in the resin phase) vs n t au (total solvent content in the resin phase) plots and separation factor, alpha(ratio of mole fraction of the solvents in the resin and solution phases) or N s vs m (molality in the resin phase) plots. The limiting values of these plots gave the composition of the solvent in the primary solvation shell around the single ion. The compositions of the primary solvation shell around Li + , Na + , and K + in methanol-water mixtures and Na + and Ag + in acetonitrile (AN) - water mixtures have been computed using Franks equation and the approach of Marcus and compared with the experimental results obtained with the above mentioned ionic forms of Dowex 50W resins in different mixed solvents. The experimental results for Li + showed good agreement with the values computed using Franks equation for all methanol-water composition. However, in the case of Na + and K + in methanol-water mixtures and Na + in AN-water mixtures, there was agreement only at lower organic solvent content and the Franks equation predicted higher values for the organic solvent in the primary solvation shell around the cation at higher organic solvent content as compared to experimental results

  6. Efter cochlear implant

    DEFF Research Database (Denmark)

    Højen, Anders

    Dit barn har netop fået et cochlear implant. Hvad nu? Skal barnet fokusere udelukkende på at lære talt sprog, eller skal det også lære/fortsætte med tegnsprog eller støttetegn? Det er et vanskeligt spørgsmål, og før valget foretages, er det vigtigt at vurdere hvilke konsekvenser valget har, dels...... for den sproglige udvikling isoleret set, og dels for barnets udvikling ud fra en helhedsbetragtning. Dette indlæg fokuserer på, hvilke forventninger man kan have til cochlear implant-brugeres sproglige udvikling med talt sprog alene, hhv. med to sprog (tale og tegn). Disse forventninger er baseret på...

  7. Delayed breast implant reconstruction

    DEFF Research Database (Denmark)

    Hvilsom, Gitte B.; Hölmich, Lisbet R.; Steding-Jessen, Marianne

    2012-01-01

    We evaluated the association between radiation therapy and severe capsular contracture or reoperation after 717 delayed breast implant reconstruction procedures (288 1- and 429 2-stage procedures) identified in the prospective database of the Danish Registry for Plastic Surgery of the Breast during...... of radiation therapy was associated with a non-significantly increased risk of reoperation after both 1-stage (HR = 1.4; 95% CI: 0.7-2.5) and 2-stage (HR = 1.6; 95% CI: 0.9-3.1) procedures. Reconstruction failure was highest (13.2%) in the 2-stage procedures with a history of radiation therapy. Breast...... reconstruction approaches other than implants should be seriously considered among women who have received radiation therapy....

  8. Piezosurgery in implant dentistry

    Science.gov (United States)

    Stübinger, Stefan; Stricker, Andres; Berg, Britt-Isabelle

    2015-01-01

    Piezosurgery, or the use of piezoelectric devices, is being applied increasingly in oral and maxillofacial surgery. The main advantages of this technique are precise and selective cuttings, the avoidance of thermal damage, and the preservation of soft-tissue structures. Through the application of piezoelectric surgery, implant-site preparation, bone grafting, sinus-floor elevation, edentulous ridge splitting or the lateralization of the inferior alveolar nerve are very technically feasible. This clinical overview gives a short summary of the current literature and outlines the advantages and disadvantages of piezoelectric bone surgery in implant dentistry. Overall, piezoelectric surgery is superior to other methods that utilize mechanical instruments. Handling of delicate or compromised hard- and soft-tissue conditions can be performed with less risk for the patient. With respect to current and future innovative surgical concepts, piezoelectric surgery offers a wide range of new possibilities to perform customized and minimally invasive osteotomies. PMID:26635486

  9. The role of ion-implantation in the realization of spintronic devices in diamond

    Energy Technology Data Exchange (ETDEWEB)

    Kalish, Rafi, E-mail: kalish@si-sun1.technion.ac.il [Physics Department and Solid State Institute, Technion-Israel Institute of Technology, Haifa 32000 (Israel)

    2012-02-01

    The application of single photons emitted by specific quantum systems is promising for quantum computers, cryptography and for other future nano-applications. These heavily rely on ion implantation both for selective single ion implantations as well as for the introduction of controlled damage with specific properties. Of particular promise is the negatively charged nitrogen-vacancy (NV{sup -}) defect center in diamond. This center has many desirable luminescence properties required for spintronic devices operational at room temperature, including a long relaxation time of the color center, emission of photons in the visible and the fact that it is produced in diamond, a material with outstanding mechanical and optical properties. This center is usually realized by nitrogen and/or vacancy producing ion implantations into diamond which, following annealing, leads to the formation of the desired NV{sup -} center. The single photons emitted by the decay of this center have to be transported to allow their exploitation. This can be best done by realizing very thin wave guides in single crystal diamond with/or without nano-scale cavities in the same diamond in which NV centers are produced. For this, advantage is taken of the unique property of heavily ion-damaged diamond to be converted, following annealing, to etchable graphite. Thus a free standing submicron thick diamond membrane containing the NV center can be obtained. If desirable, specific photonic crystal structures can be realized in them by the use of FIB. The various ion-implantation schemes used to produce NV centers in diamond, free standing diamond membranes, and photonic crystal structures in them are reviewed. The scientific problems and the technological challenges that have to be solved before actual practical realization of diamond based spintronic devices can be produced are discussed.

  10. Ion implantation in metals

    International Nuclear Information System (INIS)

    Vook, F.L.

    1977-02-01

    The application of ion beams to metals is rapidly emerging as a promising area of research and technology. This report briefly describes some of the recent advances in the modification and study of the basic properties of metals by ion implantation techniques. Most of the research discussed illustrates some of the new and exciting applications of ion beams to metals which are under active investigation at Sandia Laboratories, Albuquerque

  11. The breast implant controversy.

    Science.gov (United States)

    Cook, R R; Harrison, M C; LeVier, R R

    1994-02-01

    The breast implant issue is a "bad news/good news" story. For many women with implants, the controversy has caused a fair degree of anxiety which may or may not be resolved as further information becomes available. It has also taken its toll on Dow Corning. Whole lines of medical products have been eliminated or are being phase out. The development of new medical applications has been terminated. As a consequence, employees have lost their jobs. What the effect will be on the biomedical industry as a whole remains to be seen (11). While silicones have been an important component in various medical devices, it is likely that other materials can be used as replacements. However, suppliers of non-silicone materials are also reevaluating their role in this market. For example, Du Pont, the nation's largest chemical company, has determined that the unpredictable and excessive costs of doing business with manufacturers of implantable medical devices no longer justifies the unrestricted sale of standard raw materials into this industry. Other companies are quietly following suit. On the up side, it is possible that the research being driven by this controversy will result in a greater understanding of the immunologic implications of xenobiotics, of the importance of nonbiased observations, of the need for ready access to valid data sets, and of the opportunity for valid scientific information to guide legal decisions. Only time will tell.

  12. Cochlear implants in children implanted in Jordan: A parental overview.

    Science.gov (United States)

    Alkhamra, Rana A

    2015-07-01

    Exploring the perspective of parents on the cochlear implant process in Jordan. Sixty parents of deaf children were surveyed on the information gathering process prior to cochlear implant surgery, and their implant outcome expectations post-surgery. Whether child or parent characteristics may impact parents' post-surgical expectations was explored. Although parents used a variety of information sources when considering a cochlear implant, the ear, nose and throat doctor comprised their major source of information (60%). Parents received a range of information prior to cochlear implant but agreed (93.3%) on the need for a multidisciplinary team approach. Post-surgically, parents' expected major developments in the areas of spoken language (97%), and auditory skills (100%). Receiving education in mainstream schools (92%) was expected too. Parents perceived the cochlear implant decision as the best decision they can make for their child (98.3%). A significant correlation was found between parents contentment with the cochlear implant decision and expecting developments in the area of reading and writing (r=0.7). Child's age at implantation and age at hearing loss diagnosis significantly affected parents' post-implant outcome expectations (pparents agree on the need for a comprehensive multidisciplinary team approach during the different stages of the cochlear implant process. Parents' education about cochlear implants prior to the surgery can affect their post-surgical outcome expectations. The parental perspective presented in this study can help professionals develop better understanding of parents' needs and expectations and henceforth improve their services and support during the different stages of the cochlear implant process. Copyright © 2015. Published by Elsevier Ireland Ltd.

  13. Sub-meninges implantation reduces immune response to neural implants.

    Science.gov (United States)

    Markwardt, Neil T; Stokol, Jodi; Rennaker, Robert L

    2013-04-15

    Glial scar formation around neural interfaces inhibits their ability to acquire usable signals from the surrounding neurons. To improve neural recording performance, the inflammatory response and glial scarring must be minimized. Previous work has indicated that meningeally derived cells participate in the immune response, and it is possible that the meninges may grow down around the shank of a neural implant, contributing to the formation of the glial scar. This study examines whether the glial scar can be reduced by placing a neural probe completely below the meninges. Rats were implanted with sets of loose microwire implants placed either completely below the meninges or implanted conventionally with the upper end penetrating the meninges, but not attached to the skull. Histological analysis was performed 4 weeks following surgical implantation to evaluate the glial scar. Our results found that sub-meninges implants showed an average reduction in reactive astrocyte activity of 63% compared to trans-meninges implants. Microglial activity was also reduced for sub-meninges implants. These results suggest that techniques that isolate implants from the meninges offer the potential to reduce the encapsulation response which should improve chronic recording quality and stability. Published by Elsevier B.V.

  14. Field-Induced Single-Ion Magnet Behaviour in Two New Cobalt(II Coordination Polymers with 2,4,6-Tris(4-pyridyl-1,3,5-triazine

    Directory of Open Access Journals (Sweden)

    Dong Shao

    2017-12-01

    Full Text Available We herein reported the syntheses, crystal structures, and magnetic properties of a two-dimensional coordination polymer {[CoII(TPT2/3(H2O4][CH3COO]2·(H2O4}n (1 and a chain compound {[CoII(TPT2(CHOO2(H2O2]}n (2 based on the 2,4,6-Tris(4-pyridyl-1,3,5-triazine (TPT ligand. Structure analyses showed that complex 1 had a cationic hexagonal framework structure, while 2 was a neutral zig-zag chain structure with different distorted octahedral coordination environments. Magnetic measurements revealed that both complexes exhibit large easy-plane magnetic anisotropy with the zero-field splitting parameter D = 47.7 and 62.1 cm−1 for 1 and 2, respectively. This magnetic anisotropy leads to the field-induced slow magnetic relaxation behaviour. However, their magnetic dynamics are quite different; while complex 1 experienced a dominating thermally activated Orbach relaxation at the whole measured temperature region, 2 exhibited multiple relaxation pathways involving direct, Raman, and quantum tunneling (QTM processes at low temperatures and Orbach relaxation at high temperatures. The present complexes enlarge the family of framework-based single-ion magnets (SIMs and highlight the significance of the structural dimensionality to the final magnetic properties.

  15. Improving osseointegration of dental implants.

    Science.gov (United States)

    Elias, Carlos Nelson; Meirelles, Luiz

    2010-03-01

    In the beginning of implantology, the procedures adopted for treating patients were performed in two surgical phases with an interval of 3-6 months. Nowadays, it is possible to insert and load a dental implant in the same surgical procedure. This change is due to several factors, such as improvement of surgical technique, modifications of the implant design, increased quality of implant manufacturing, development of the surgical instruments' quality, careful patient screening and adequate treatment of the implant surface. The clinical results show that adequate treatment of surfaces is crucial for reducing healing time and treating at-risk patients. The surface properties of dental implants can be significantly improved at the manufacturing stage, affecting cells' activity during the healing phase that will ultimately determine the host tissue response, a fundamental requirement for clinical success. This review focuses on different types of dental implant surfaces and the influence of surface characteristics on osseointegration.

  16. The thermal evolution of targets under plasma focus pulsed ion implantation

    International Nuclear Information System (INIS)

    Sanchez, G.; Feugeas, J.

    1997-01-01

    Pulsed ion beam implantation with plasma focus has proved to be an effective method of metal surface treatment for tribological purposes. Nevertheless, the pulsed nature and the continuous energy spectrum of the ion beams differ from those of the standard ion implantation processes. In this paper a model of the thermal evolution of the surface layers of stainless steel, titanium and copper, during and after nitrogen and argon ion beam incidence, is presented using the finite-difference method. In the calculations, the geometry and physical characteristics of the ion beams, the single-ion-solid interaction process and the thermal properties of the materials were used. The results showed a strong thermal effect consisting in the generation of transitory heating slopes and heating speeds as high as ∼3600 K μm -1 and ∼40 K ns -1 respectively, with maximum temperatures that can reach even the material evaporation point at the surface layers. The cooling down process, through the thermal conduction mechanism at the target bulk, turns out to be fast enough to produce the complete thermal relaxation of the target in only a few microseconds after the end of the ion beam incidence. The results presented are contrasted with experiments performed in similar conditions to those used in the numerical model. (Author)

  17. Immediate Direct-To-Implant Breast Reconstruction Using Anatomical Implants

    Directory of Open Access Journals (Sweden)

    Sung-Eun Kim

    2014-09-01

    Full Text Available BackgroundIn 2012, a new anatomic breast implant of form-stable silicone gel was introduced onto the Korean market. The intended use of this implant is in the area of aesthetic breast surgery, and many reports are promising. Thus far, however, there have been no reports on the use of this implant for breast reconstruction in Korea. We used this breast implant in breast reconstruction surgery and report our early experience.MethodsFrom November 2012 to April 2013, the Natrelle Style 410 form-stable anatomically shaped cohesive silicone gel-filled breast implant was used in 31 breasts of 30 patients for implant breast reconstruction with an acellular dermal matrix. Patients were treated with skin-sparing mastectomies followed by immediate breast reconstruction.ResultsThe mean breast resection volume was 240 mL (range, 83-540 mL. The mean size of the breast implants was 217 mL (range, 125-395 mL. Breast shape outcomes were considered acceptable. Infection and skin thinning occurred in one patient each, and hematoma and seroma did not occur. Three cases of wound dehiscence occurred, one requiring surgical intervention, while the others healed with conservative treatment in one month. Rippling did not occur. So far, complications such as capsular contracture and malrotation of breast implant have not yet arisen.ConclusionsBy using anatomic breast implants in breast reconstruction, we achieved satisfactory results with aesthetics better than those obtained with round breast implants. Therefore, we concluded that the anatomical implant is suitable for breast reconstruction.

  18. Dental implants in growing children

    Directory of Open Access Journals (Sweden)

    S K Mishra

    2013-01-01

    Full Text Available The replacement of teeth by implants is usually restricted to patients with completed craniofacial growth. The aim of this literature review is to discuss the use of dental implants in normal growing patients and in patients with ectodermal dysplasia and the influence of maxillary and mandibular skeletal and dental growth on the stability of those implants. It is recommended that while deciding the optimal individual time point of implant insertion, the status of skeletal growth, the degree of hypodontia, and extension of related psychological stress should be taken into account, in addition to the status of existing dentition and dental compliance of a pediatric patient.

  19. Printing of Titanium implant prototype

    International Nuclear Information System (INIS)

    Wiria, Florencia Edith; Shyan, John Yong Ming; Lim, Poon Nian; Wen, Francis Goh Chung; Yeo, Jin Fei; Cao, Tong

    2010-01-01

    Dental implant plays an important role as a conduit of force and stress to flow from the tooth to the related bone. In the load sharing between an implant and its related bone, the amount of stress carried by each of them directly related to their stiffness or modulus. Hence, it is a crucial issue for the implant to have matching mechanical properties, in particular modulus, between the implant and its related bone. Titanium is a metallic material that has good biocompatibility and corrosion resistance. Whilst the modulus of the bulk material is still higher than that of bone, it is the lowest among all other commonly used metallic implant materials, such as stainless steel or cobalt alloy. Hence it is potential to further reduce the modulus of pure Titanium by engineering its processing method to obtain porous structure. In this project, porous Titanium implant prototype is fabricated using 3-dimensional printing. This technique allows the flexibility of design customization, which is beneficial for implant fabrication as tailoring of implant size and shape helps to ensure the implant would fit nicely to the patient. The fabricated Titanium prototype had a modulus of 4.8-13.2 GPa, which is in the range of natural bone modulus. The compressive strength achieved was between 167 to 455 MPa. Subsequent cell culture study indicated that the porous Titanium prototype had good biocompatibility and is suitable for bone cell attachment and proliferation.

  20. Cochlear implantation in Mondini dysplasia.

    Science.gov (United States)

    Daneshi, Ahmad; Hassanzadeh, Saeid; Abasalipour, Parvaneh; Emamdjomeh, Hessamaddin; Farhadi, Mohammad

    2003-01-01

    The use of cochlear implantation to treat patients with inner ear malformations such as Mondini dysplasia has been increasingly successful. Until now, conventional hearing aids in these patients have not performed well. Consequently, the hearing problem for patients with this condition has been somewhat improved with the use of cochlear implants. Various results of cochlear implantation have been reported in these patients so far. This is a report of 5 patients with Mondini malformation who have undergone cochlear implant surgery. Copyright 2003 S. Karger AG, Basel

  1. Implant-retained maxillary overdentures.

    Science.gov (United States)

    Eckert, Steven E; Carr, Alan B

    2004-07-01

    Overdentures supported by osseointegrated implants overcome many of the complications observed with overdentures supported by natural teeth. Dental implants are free of biologic consequences associated with natural teeth, such as dental caries and periodontal disease. Bone undercuts adjacent to implants do not mimic those found adjacent to natural tooth roots. Implants are used to provide predictable retention, support, and stability for overdenture prostheses. When lip or facial support is required, the overdenture is the treatment of choice. Likewise the overdenture may improve phonetic deficiencies associated with alveolar bone loss.

  2. Cochlear implants in Waardenburg syndrome.

    Science.gov (United States)

    Cullen, Robert D; Zdanski, Carlton; Roush, Patricia; Brown, Carolyn; Teagle, Holly; Pillsbury, Harold C; Buchman, Craig

    2006-07-01

    Waardenburg syndrome is an autosomal-dominant syndrome characterized by dystopia canthorum, hyperplasia of the eyebrows, heterochromia irides, a white forelock, and sensorineural hearing loss in 20% to 55% of patients. This patient population accounts for approximately 2% of congenitally deaf children. The purpose of this retrospective case review was to describe the outcomes for those children with Waardenburg syndrome who have undergone cochlear implantation. Pediatric cochlear implant recipients with documented evidence of Waardenburg syndrome underwent retrospective case review. All patients received their cochlear implants at the study institution followed by outpatient auditory habilitation. Charts were reviewed for etiology and duration of deafness, age at time of cochlear implantation, perioperative complications, duration of use, and performance outcomes. Results of standard tests batteries for speech perception and production administered as a part of the patients' auditory habilitation were reviewed. Seven patients with Waardenburg syndrome and cochlear implants were identified. The average age at implantation was 37 months (range, 18-64 months) and the average duration of use was 69 months (range, 12-143 months). All of these patients are active users of their devices and perform very well after implantation. There were no major complications in this small group of patients. Children with congenital sensorineural hearing loss without other comorbidities (e.g., developmental delay, inner ear malformations) perform well when they receive cochlear implantation and auditory habilitation. Patients with Waardenburg syndrome can be expected to have above-average performance after cochlear implantation.

  3. Single-ion nonlinear mechanical oscillator

    International Nuclear Information System (INIS)

    Akerman, N.; Kotler, S.; Glickman, Y.; Dallal, Y.; Keselman, A.; Ozeri, R.

    2010-01-01

    We study the steady-state motion of a single trapped ion oscillator driven to the nonlinear regime. Damping is achieved via Doppler laser cooling. The ion motion is found to be well described by the Duffing oscillator model with an additional nonlinear damping term. We demonstrate here the unique ability of tuning both the linear as well as the nonlinear damping coefficients by controlling the laser-cooling parameters. Our observations pave the way for the investigation of nonlinear dynamics on the quantum-to-classical interface as well as mechanical noise squeezing in laser-cooling dynamics.

  4. Age at implantation and auditory memory in cochlear implanted children.

    Science.gov (United States)

    Mikic, B; Miric, D; Nikolic-Mikic, M; Ostojic, S; Asanovic, M

    2014-05-01

    Early cochlear implantation, before the age of 3 years, provides the best outcome regarding listening, speech, cognition an memory due to maximal central nervous system plasticity. Intensive postoperative training improves not only auditory performance and language, but affects auditory memory as well. The aim of this study was to discover if the age at implantation affects auditory memory function in cochlear implanted children. A total of 50 cochlear implanted children aged 4 to 8 years were enrolled in this study: early implanted (1-3y) n = 27 and late implanted (4-6y) n = 23. Two types of memory tests were used: Immediate Verbal Memory Test and Forward and Backward Digit Span Test. Early implanted children performed better on both verbal and numeric tasks of auditory memory. The difference was statistically significant, especially on the complex tasks. Early cochlear implantation, before the age of 3 years, significantly improve auditory memory and contribute to better cognitive and education outcomes.

  5. Cluster Implantation and Deposition Apparatus

    DEFF Research Database (Denmark)

    Hanif, Muhammad; Popok, Vladimir

    2015-01-01

    In the current report, a design and capabilities of a cluster implantation and deposition apparatus (CIDA) involving two different cluster sources are described. The clusters produced from gas precursors (Ar, N etc.) by PuCluS-2 can be used to study cluster ion implantation in order to develop...

  6. Porous metal for orthopedics implants

    OpenAIRE

    Matassi, Fabrizio; Botti, Alessandra; Sirleo, Luigi; Carulli, Christian; Innocenti, Massimo

    2013-01-01

    Porous metal has been introduced to obtain biological fixation and improve longevity of orthopedic implants. The new generation of porous metal has intriguing characteristics that allows bone healing and high osteointegration of the metallic implants. This article gives an overview about biomaterials properties of the contemporary class of highly porous metals and about the clinical use in orthopaedic surgery.

  7. [The impact of dental implants

    NARCIS (Netherlands)

    Meijer, G.J.

    2013-01-01

    The importance of the introduction of dental implants can only be understood when the historical context is clarified. In the past, the main treatment carried out by dentists consisted of filling or, in unfortunate cases, removal of painful teeth. Only since the introduction of dental implants did

  8. Sequential provisional implant prosthodontics therapy.

    Science.gov (United States)

    Zinner, Ira D; Markovits, Stanley; Jansen, Curtis E; Reid, Patrick E; Schnader, Yale E; Shapiro, Herbert J

    2012-01-01

    The fabrication and long-term use of first- and second-stage provisional implant prostheses is critical to create a favorable prognosis for function and esthetics of a fixed-implant supported prosthesis. The fixed metal and acrylic resin cemented first-stage prosthesis, as reviewed in Part I, is needed for prevention of adjacent and opposing tooth movement, pressure on the implant site as well as protection to avoid micromovement of the freshly placed implant body. The second-stage prosthesis, reviewed in Part II, should be used following implant uncovering and abutment installation. The patient wears this provisional prosthesis until maturation of the bone and healing of soft tissues. The second-stage provisional prosthesis is also a fail-safe mechanism for possible early implant failures and also can be used with late failures and/or for the necessity to repair the definitive prosthesis. In addition, the screw-retained provisional prosthesis is used if and when an implant requires removal or other implants are to be placed as in a sequential approach. The creation and use of both first- and second-stage provisional prostheses involve a restorative dentist, dental technician, surgeon, and patient to work as a team. If the dentist alone cannot do diagnosis and treatment planning, surgery, and laboratory techniques, he or she needs help by employing the expertise of a surgeon and a laboratory technician. This team approach is essential for optimum results.

  9. Piezosurgery in implant dentistry

    Directory of Open Access Journals (Sweden)

    Stübinger S

    2015-11-01

    Full Text Available Stefan Stübinger,1 Andres Stricker,2 Britt-Isabelle Berg3,4 1Hightech Research Center of Cranio-maxillofacial Surgery, University of Basel, Allschwil, Switzerland; 2Private Practice, Konstanz, Germany; 3Department of Cranio-maxillofacial Surgery, University Hospital Basel, Basel, Switzerland; 4Division of Oral and Maxillofacial Radiology, Columbia University Medical Center, New York, NY, USA Abstract: Piezosurgery, or the use of piezoelectric devices, is being applied increasingly in oral and maxillofacial surgery. The main advantages of this technique are precise and selective cuttings, the avoidance of thermal damage, and the preservation of soft-tissue structures. Through the application of piezoelectric surgery, implant-site preparation, bone grafting, sinus-floor elevation, edentulous ridge splitting or the lateralization of the inferior alveolar nerve are very technically feasible. This clinical overview gives a short summary of the current literature and outlines the advantages and disadvantages of piezoelectric bone surgery in implant dentistry. Overall, piezoelectric surgery is superior to other methods that utilize mechanical instruments. Handling of delicate or compromised hard- and soft-tissue conditions can be performed with less risk for the patient. With respect to current and future innovative surgical concepts, piezoelectric surgery offers a wide range of new possibilities to perform customized and minimally invasive osteotomies. Keywords: implantology, piezoelectric device, piezosurgery, maxillary sinus elevation, bone grafting, osteotomy, edentulous ridge splitting

  10. Labyrinthectomy with cochlear implantation.

    Science.gov (United States)

    Zwolan, T A; Shepard, N T; Niparko, J K

    1993-05-01

    Numerous reports indicate that the cochlea remains responsive to electrical stimulation following labyrinthectomy. We report a case of a 47-year-old woman with a severe to profound sensorineural hearing loss from birth, who developed episodic vertigo with symptoms suggestive of delayed onset endolymphatic hydrops. Following 8 months of failed medical and vestibular rehabilitation management, a right-sided labyrinthectomy combined with cochlear implantation was performed without complication. Postoperatively the patient was free of vertigo. Attempts to activate the patient's device between 4 to 12 weeks after surgery were unsuccessful as stimulation of the electrodes resulted in discomfort. However, all 20 electrodes elicited comfortable hearing sensations 16 weeks postsurgery. One year after the successful activation, the patient demonstrated improved sound awareness and speech recognition with the implant when compared with preoperative performance with a hearing aid. This case study suggests that electrical detection thresholds with prosthetic stimulation may be unstable in the recently labyrinthectomized ear but supports and extends prior observations of preserved cochlear responsiveness after labyrinthectomy.

  11. Ion implantation and amorphous metals

    International Nuclear Information System (INIS)

    Hohmuth, K.; Rauschenbach, B.

    1981-01-01

    This review deals with ion implantation of metals in the high concentration range for preparing amorphous layers (>= 10 at%, implantation doses > 10 16 ions/cm 2 ). Different models are described concerning formation of amorphous phases of metals by ion implantation and experimental results are given. The study of amorphous phases has been carried out by the aid of Rutherford backscattering combined with the channeling technique and using transmission electron microscopy. The structure of amorphous metals prepared by ion implantation has been discussed. It was concluded that amorphous metal-metalloid compounds can be described by a dense-random-packing structure with a great portion of metal atoms. Ion implantation has been compared with other techniques for preparing amorphous metals and the adventages have been outlined

  12. Ion implantation: an annotated bibliography

    International Nuclear Information System (INIS)

    Ting, R.N.; Subramanyam, K.

    1975-10-01

    Ion implantation is a technique for introducing controlled amounts of dopants into target substrates, and has been successfully used for the manufacture of silicon semiconductor devices. Ion implantation is superior to other methods of doping such as thermal diffusion and epitaxy, in view of its advantages such as high degree of control, flexibility, and amenability to automation. This annotated bibliography of 416 references consists of journal articles, books, and conference papers in English and foreign languages published during 1973-74, on all aspects of ion implantation including range distribution and concentration profile, channeling, radiation damage and annealing, compound semiconductors, structural and electrical characterization, applications, equipment and ion sources. Earlier bibliographies on ion implantation, and national and international conferences in which papers on ion implantation were presented have also been listed separately

  13. Tribological properties of nitrogen implanted and boron implanted steels

    International Nuclear Information System (INIS)

    Kern, K.T.

    1996-01-01

    Samples of a steel with high chrome content was implanted separately with 75 keV nitrogen ions and with 75 keV boron ions. Implanted doses of each ion species were 2-, 4-, and 8 x 10 17 /cm 2 . Retained doses were measured using resonant non-Rutherford Backscattering Spectrometry. Tribological properties were determined using a pin-on-disk test with a 6-mm diameter ruby pin with a velocity of 0.94 m/min. Testing was done at 10% humidity with a load of 377 g. Wear rate and coefficient of friction were determined from these tests. While reduction in the wear rate for nitrogen implanted materials was observed, greater reduction (more than an order of magnitude) was observed for boron implanted materials. In addition, reduction in the coefficient of friction for high-dose boron implanted materials was observed. Nano-indentation revealed a hardened layer near the surface of the material. Results from grazing incidence x-ray diffraction suggest the formation of Fe 2 N and Fe 3 N in the nitrogen implanted materials and Fe 3 B in the boron implanted materials. Results from transmission electron microscopy will be presented

  14. Cochlear implantation in late-implanted adults with prelingual deafness.

    Science.gov (United States)

    Most, Tova; Shrem, Hadas; Duvdevani, Ilana

    2010-01-01

    The purpose of this study was to examine the effect of cochlear implantation (CI) on prelingually deafened participants who were implanted as adults. The effect of the CI was examined with regard to the following variables: communication, family, social skills, education, and work satisfaction with one's life, loneliness, and self-esteem. Thirty-eight adults participated. Four self-report questionnaires were used at 2 points in time: before and after CI. The research findings show significant differences in the reports of most variables before and after implantation. The participants felt better with regard to communication, social skills, education, and work and satisfaction with one's life after implantation in comparison to their feelings before implantation. Furthermore, they felt less lonely after implantation. However, there were no significant differences before and after implantation regarding their feelings within the family and regarding their self-esteem. The results demonstrated the need to evaluate the benefits resulting from the CI not only with traditional clinical measures but with additional measures as well. Furthermore, they demonstrated the benefit of the CI on the positive psychosociological implications of prelingually deafened adults. Copyright © 2010 Elsevier Inc. All rights reserved.

  15. A Retrospective Analysis of Ruptured Breast Implants

    Directory of Open Access Journals (Sweden)

    Woo Yeol Baek

    2014-11-01

    Full Text Available BackgroundRupture is an important complication of breast implants. Before cohesive gel silicone implants, rupture rates of both saline and silicone breast implants were over 10%. Through an analysis of ruptured implants, we can determine the various factors related to ruptured implants.MethodsWe performed a retrospective review of 72 implants that were removed for implant rupture between 2005 and 2014 at a single institution. The following data were collected: type of implants (saline or silicone, duration of implantation, type of implant shell, degree of capsular contracture, associated symptoms, cause of rupture, diagnostic tools, and management.ResultsForty-five Saline implants and 27 silicone implants were used. Rupture was diagnosed at a mean of 5.6 and 12 years after insertion of saline and silicone implants, respectively. There was no association between shell type and risk of rupture. Spontaneous was the most common reason for the rupture. Rupture management was implant change (39 case, microfat graft (2 case, removal only (14 case, and follow-up loss (17 case.ConclusionsSaline implants have a shorter average duration of rupture, but diagnosis is easier and safer, leading to fewer complications. Previous-generation silicone implants required frequent follow-up observation, and it is recommended that they be changed to a cohesive gel implant before hidden rupture occurs.

  16. [Maintenance care for dental implant].

    Science.gov (United States)

    Kamoi, K

    1989-10-01

    Dental implant has tried at the early stage in 19th century recovering an oral function and esthetics. Technological revolutions in biochemical and new materials have developed on the remarkable change in the dental implants, nowadays we call the three generation therapy for dental implantology. There are many kinds of methods and techniques in dental implants, however a lot of troublesome complication on the process of surgical phase, construction of prothodontics and prognosis of maintenance care. In the proceedings of this symposium, I would like to propose you how to manage the maintenance care for various kind of dental implants through the methodology and case presentations. Tendenay and future for dental implants The current outlook of dental implant has increasing supply and demand not only dentists but also patients. According to Japanese Welfare Ministry's report in 1987, average missing teeth over sixty years old generations are approximately 42% in accordance with NIDR (U.S.A.) research. They are missed on ten over teeth in full 28th teeth dentitions owing to dental caries and periodontal diseases. Generally speaking, latent implant patients are occupied on the same possibility of needs for dental implants both Japan and U.S.A. Management of maintenance care The patients hardly recognized the importance of plaque control for the maintenance care in the intraoral condition after implantation. Dentists and dental staffs must be instruct patients for importance of plaque removal and control, because they already had forgotten the habit of teeth cleaning, especially in the edenturous conditions. 1) Concept of establishment in oral hygiene. Motivation and instruction for patients include very important factors in dental implants as well as in periodontal diseases. Patients who could not achieve on good oral hygiene levels obtained no good results in the long term observations. To establish good oral hygiene are how to control supra plaque surrounding tissues

  17. Ion implantation apparatus

    International Nuclear Information System (INIS)

    Forneris, J.L.; Hicks, W.W.; Keller, J.H.; McKenna, C.M.; Siermarco, J.A.; Mueller, W.F.

    1981-01-01

    The invention relates to ion bombardment or implantation apparatus. It comprises an apparatus for bombarding a target with a beam of ions, including an arrangement for measuring the ion beam current and controlling the surface potential of the target. This comprises a Faraday cage formed, at least in part, by the target and by walls adjacent to, and electrically insulated from, the target and surrounding the beam. There is at least one electron source for supplying electrons to the interior of the Faraday cage and means within the cage for blocking direct rectilinear radiation from the source to the target. The target current is measured and combined with the wall currents to provide a measurement of the ion beam current. The quantity of electrons supplied to the interior of the cage can be varied to control the target current and thereby the target surface potential. (U.K.)

  18. Implantable biochemical fuel cell

    Energy Technology Data Exchange (ETDEWEB)

    Richter, G; Rao, J R

    1978-01-05

    Implantable biochemical fuel cells for the operation of heart pacemakers or artificial hearts convert oxidisable body substances such as glucose on the anode side and reduce the oxygen contained in body fluids at the cathode. The anode and cathode are separated by membranes which are impermeable to albumen and blood corpuscles in body fluids. A chemical shortcircuit cannot occur in practice if, according to the invention, one or more selective oxygen electrodes with carbon as catalyst are arranged so that the mixture which diffuses into the cell from body fluids during operation reaches the fuel cell electrode through the porous oxygen electrode. The membranes used must be permeable to water. Cellulose, polymerised polyvinyl alcohol or an ion exchanger with a buffering capacity between pH5 and 8 act as permeable materials.

  19. Implant materials modified by colloids

    Directory of Open Access Journals (Sweden)

    Zboromirska-Wnukiewicz Beata

    2016-03-01

    Full Text Available Recent advances in general medicine led to the development of biomaterials. Implant material should be characterized by a high biocompatibility to the tissue and appropriate functionality, i.e. to have high mechanical and electrical strength and be stable in an electrolyte environment – these are the most important properties of bioceramic materials. Considerations of biomaterials design embrace also electrical properties occurring on the implant-body fluid interface and consequently the electrokinetic potential, which can be altered by modifying the surface of the implant. In this work, the surface of the implants was modified to decrease the risk of infection by using metal colloids. Nanocolloids were obtained using different chemical and electrical methods. It was found that the colloids obtained by physical and electrical methods are more stable than colloids obtained by chemical route. In this work the surface of modified corundum implants was investigated. The implant modified by nanosilver, obtained by electrical method was selected. The in vivo research on animals was carried out. Clinical observations showed that the implants with modified surface could be applied to wounds caused by atherosclerotic skeleton, for curing the chronic and bacterial inflammations as well as for skeletal reconstruction surgery.

  20. Basic research on maxillofacial implants

    Energy Technology Data Exchange (ETDEWEB)

    Matsui, Yoshiro [Showa Univ., Tokyo (Japan). School of Dentistry

    2001-11-01

    Osseointegrated implants have begun to be used not only in general practice in dentistry but also in various clinical situations in the maxillofacial region. The process has yielded three problems: the spread of application, new materials and diagnostic methods, and management for difficult situations. This paper presents basic data and clinical guidelines for new applications, it investigates the characteristics of the materials and the usefulness of a new diagnostic method, and it studies effective techniques for difficult cases. The results obtained are as follows: Investigations into the spreading application. The lateral and superior orbital rim have sufficient bone thickness and width for the implant body to be placed. Osseointegrated implants, especially by the fixed bridge technique, are not recommended in the craniofacial bone and jaws of young children. Implant placement into bone after/before irradiation must be performed in consideration of impaired osteogenesis, the decrease of trabecular bone, and the time interval between implantation and irradiation. Investigations into materials and diagnostic methods. Hydroxyapatite-coated and titanium implants should be selected according to the characteristics of the materials. A dental simulating soft may also be applicable in the craniofacial region. Investigations into the management of difficult cases. Hyperbaric oxygen therapy (HBO), bone morphogenetic protein (BMP), and tissue engineering should be useful for improving the quality and increasing the quantity of bone where implants are placed. Soft tissue around implants placed in the reconstructed area should be replaced with mucosal tissue. The data obtained here should be useful for increasing the efficiency of osseointegrated implants, but further basic research is required in the future. (author)

  1. Basic research on maxillofacial implants

    International Nuclear Information System (INIS)

    Matsui, Yoshiro

    2001-01-01

    Osseointegrated implants have begun to be used not only in general practice in dentistry but also in various clinical situations in the maxillofacial region. The process has yielded three problems: the spread of application, new materials and diagnostic methods, and management for difficult situations. This paper presents basic data and clinical guidelines for new applications, it investigates the characteristics of the materials and the usefulness of a new diagnostic method, and it studies effective techniques for difficult cases. The results obtained are as follows: Investigations into the spreading application. The lateral and superior orbital rim have sufficient bone thickness and width for the implant body to be placed. Osseointegrated implants, especially by the fixed bridge technique, are not recommended in the craniofacial bone and jaws of young children. Implant placement into bone after/before irradiation must be performed in consideration of impaired osteogenesis, the decrease of trabecular bone, and the time interval between implantation and irradiation. Investigations into materials and diagnostic methods. Hydroxyapatite-coated and titanium implants should be selected according to the characteristics of the materials. A dental simulating soft may also be applicable in the craniofacial region. Investigations into the management of difficult cases. Hyperbaric oxygen therapy (HBO), bone morphogenetic protein (BMP), and tissue engineering should be useful for improving the quality and increasing the quantity of bone where implants are placed. Soft tissue around implants placed in the reconstructed area should be replaced with mucosal tissue. The data obtained here should be useful for increasing the efficiency of osseointegrated implants, but further basic research is required in the future. (author)

  2. Surface modifications of dental implants.

    Science.gov (United States)

    Stanford, C M

    2008-06-01

    Dental implant surface technologies have been evolving rapidly to enhance a more rapid bone formation on their surface and hold a potential to increase the predictability of expedited implant therapy. While implant outcomes have become highly predictable, there are sites and conditions that result in elevated implant loss. This paper reviews the impact of macro-retentive features which includes approaches to surface oxide modification, thread design, press-fit and sintered-bead technologies to increase predictability of outcomes. Implant designs that lead to controlled lateral compression of the bone can improve primary stability as long as the stress does not exceed the localized yield strength of the cortical bone. Some implant designs have reduced crestal bone loss by use of multiple cutting threads that are closely spaced, smoothed on the tip but designed to create a hoop-stress stability of the implant as it is completely seated in the osteotomy. Following the placement of the implant, there is a predictable sequence of bone turnover and replacement at the interface that allows the newly formed bone to adapt to microscopic roughness on the implant surface, and on some surfaces, a nanotopography (<10(-9) m scale) that has been shown to preferably influence the formation of bone. Newly emerging studies show that bone cells are exquisitely sensitive to these topographical features and will upregulate the expression of bone related genes for new bone formation when grown on these surfaces. We live in an exciting time of rapid changes in the modalities we can offer patients for tooth replacement therapy. Given this, it is our responsibility to be critical when claims are made, incorporate into our practice what is proven and worthwhile, and to continue to support and provide the best patient care possible.

  3. COCHLEAR IMPLANTATION PREVALENCE IN ELDERLY

    Directory of Open Access Journals (Sweden)

    A. V. Starokha

    2014-01-01

    Full Text Available Current paper describes an experience of cochlear implantation in elderly. Cochlear implantation has become a widely accepted intervention in the treatment of individuals with severe-to-profound sensorineural hearing loss. Cochlear implants are now accepted as a standard of care to optimize hearing and subsequent speech development in children and adults with deafness. But cochlear implantation affects not only hearing abilities, speech perception and speech production; it also has an outstanding impact on the social life, activities and self-esteem of each patient. The aim of this study was to evaluate the cochlear implantation efficacy in elderly with severe to profound sensorineural hearing loss. There were 5 patients under our observation. Surgery was performed according to traditional posterior tympanotomy and cochleostomy for cochlear implant electrode insertion for all observed patients. The study was conducted in two stages: before speech processor’s activation and 3 months later. Pure tone free field audiometry was performed to each patient to assess the efficiency of cochlear implantation in dynamics. The aim of the study was also to evaluate quality of life in elderly with severe to profound sensorineural hearing loss after unilateral cochlear implantation. Each patient underwent questioning with 36 Item Short Form Health Survey (SF-36. SF-36 is a set of generic, coherent, and easily administered quality-of-life measures. The SF-36 consists of eight scaled scores, which are the weighted sums of the questions in their section. Each scale is directly transformed into a 0-100 scale on the assumption that each question carries equal weight. The eight sections are: physical functioning; physical role functioning; emotional role functioning; vitality; emotional well-being; social role functioning; bodily pain; general health perceptions. Our results demonstrate that cochlear implantation in elderly consistently improved quality of life

  4. Scalloped Implant-Abutment Connection Compared to Conventional Flat Implant-Abutment Connection

    DEFF Research Database (Denmark)

    Starch-Jensen, Thomas; Christensen, Ann-Eva; Lorenzen, Henning

    2017-01-01

    OBJECTIVES: The objective was to test the hypothesis of no difference in implant treatment outcome after installation of implants with a scalloped implant-abutment connection compared to a flat implant-abutment connection. MATERIAL AND METHODS: A MEDLINE (PubMed), Embase and Cochrane library search...... of suprastructures has never been compared within the same study. High implant survival rate was reported in all the included studies. Significantly more peri-implant marginal bone loss, higher probing depth score, bleeding score and gingival score was observed around implants with a scalloped implant-abutment...... loss around implants with a scalloped implant-abutment connection. CONCLUSIONS: A scalloped implant-abutment connection seems to be associated with higher peri-implant marginal bone loss compared to a flat implant-abutment connection. Therefore, the hypothesis of the present systematic review must...

  5. Implantable cardioverter defibrillator implantation in children in The Netherlands

    NARCIS (Netherlands)

    Ten Harkel, ADJ; Blom, NA; Reimer, AG; Tukkie, R; Sreeram, N; Bink-Boelkens, MTE

    To evaluate the indications, underlying cardiac disorders, efficacy and complications involved with implantable cardioverter-defibrillators (ICDs) in paediatric patients in The Netherlands, the records of all patients aged 18 years or younger who underwent ICD placement were reviewed

  6. Implantable cardioverter defibrillator implantation in children in The Netherlands

    NARCIS (Netherlands)

    ten Harkel, A. Derk Jan; Blom, Nico A.; Reimer, Annette G.; Tukkie, Raymond; Sreeram, Narayanswami; Bink-Boelkens, Margreet T. E.

    2005-01-01

    To evaluate the indications, underlying cardiac disorders, efficacy and complications involved with implantable cardioverter-defibrillators (ICDs) in paediatric patients in The Netherlands, the records of all patients aged 18 years or younger who underwent ICD placement were reviewed

  7. Nitrogen implantation in steel with an impulsive ion implanter

    International Nuclear Information System (INIS)

    Feugeas, J.N.; Gonzalez, C.O.; Hermida, J.; Nieto, M.; Peyronel, M.F.; Sanchez, G.

    1990-01-01

    This work describes the results of steel implantation with nitrogen, with a pulsed accelerator which provides a continuous ion energy spectrum giving a uniform profile of nitrogen without changing its operative conditions. (Author)

  8. Ion implantation in semiconductor bodies

    International Nuclear Information System (INIS)

    Badawi, M.H.

    1984-01-01

    Ions are selectively implanted into layers of a semiconductor substrate of, for example, semi-insulating gallium arsenide via a photoresist implantation mask and a metallic layer of, for example, titanium disposed between the substrate surface and the photoresist mask. After implantation the mask and metallic layer are removed and the substrate heat treated for annealing purposes. The metallic layer acts as a buffer layer and prevents possible contamination of the substrate surface, by photoresist residues, at the annealing stage. Such contamination would adversely affect the electrical properties of the substrate surface, particularly gallium arsenide substrates. (author)

  9. Hardness of ion implanted ceramics

    International Nuclear Information System (INIS)

    Oliver, W.C.; McHargue, C.J.; Farlow, G.C.; White, C.W.

    1985-01-01

    It has been established that the wear behavior of ceramic materials can be modified through ion implantation. Studies have been done to characterize the effect of implantation on the structure and composition of ceramic surfaces. To understand how these changes affect the wear properties of the ceramic, other mechanical properties must be measured. To accomplish this, a commercially available ultra low load hardness tester has been used to characterize Al 2 O 3 with different implanted species and doses. The hardness of the base material is compared with the highly damaged crystalline state as well as the amorphous material

  10. An introduction to single implant abutments.

    LENUS (Irish Health Repository)

    Warreth, Abdulhadi

    2013-01-01

    This article is an introduction to single implant abutments and aims to provide basic information about abutments which are essential for all dental personnel who are involved in dental implantology. Clinical Relevance: This article provides a basic knowledge of implants and implant abutments which are of paramount importance, as replacement of missing teeth with oral implants has become a well-established clinical procedure.

  11. Cochlear implantation in a bilateral Mondini dysplasia.

    Science.gov (United States)

    Turrini, M; Orzan, E; Gabana, M; Genovese, E; Arslan, E; Fisch, U

    1997-01-01

    We report the speech perception progress and programming procedures of a case of congenital profound deafness and bilateral Mondini dysplasia implanted with a Nucleus 20 + 2 cochlear implant at the age of six. Unclear relations between electrodes array and cochlear partition made implant programming difficult and non-standard procedures were set. Cochlear implantation may give excellent rehabilitative results also in cochleae with malformation.

  12. Implant retention systems for implant-retained overdentures.

    Science.gov (United States)

    Laverty, D P; Green, D; Marrison, D; Addy, L; Thomas, M B M

    2017-03-10

    Implant retained overdentures are being increasingly utilised in both general and specialist practice to rehabilitate patients with missing teeth, particularly those that are edentate. This article aims to inform the reader of a variety of retention systems that are available to retain an implant overdenture and to understand how these systems work, their advantages and disadvantages and to outline some of the clinical and treatment planning considerations involved in selecting the most appropriate retention system for patients.

  13. Implant Materials Generate Different Peri-implant Inflammatory Factors

    OpenAIRE

    Olivares-Navarrete, Rene; Hyzy, Sharon L.; Slosar, Paul J.; Schneider, Jennifer M.; Schwartz, Zvi; Boyan, Barbara D.

    2015-01-01

    Study Design. An in vitro study examining factors produced by human mesenchymal stem cells on spine implant materials. Objective. The aim of this study was to examine whether the inflammatory microenvironment generated by cells on titanium-aluminum-vanadium (Ti-alloy, TiAlV) surfaces is affected by surface microtexture and whether it differs from that generated on poly-ether-ether-ketone (PEEK). Summary of Background Data. Histologically, implants fabricated from PEEK have a fibrous connectiv...

  14. Structure of ion-implanted ceramics

    International Nuclear Information System (INIS)

    Naramoto, Hiroshi

    1983-01-01

    The variation of structure of LiF, MgO, Al 2 O 3 and TiO 2 accompanying annealing after ion implantation is explained. The analysis of structure is usually made by the perturbed gamma ray angular correlation, the internal electron Moessbauer method, or the ion scattering method. The results of analyses are discussed for alkali ion implantation, Fe-ion implantation, In-ion implantation, Au-ion implantation, Pt-ion implantation, Pb-ion implantation and transition metal ion implantation. The coupling of the implanted elements with lattice defects and matrix elements, and the compatibility between deposited elements and matrix crystal lattice were studied. The variation of physical properties due to ion implantation such as phase transition, volume change, the control of single crystal region, and the variation of hardness near surface were investigated, and the examples are presented. (Kato, T.)

  15. Surface microhardening by ion implantation

    International Nuclear Information System (INIS)

    Singh, Amarjit

    1986-01-01

    The paper discusses the process and the underlying mechanism of surface microhardening by implanting suitable energetic ions in materials like 4145 steel, 304 stainless steel, aluminium and its 2024-T351 alloy. It has been observed that boron and nitrogen implantation in materials like 4145 steel and 304 stainless steel can produce a significant increase in surface hardness. Moreover the increase can be further enhanced with suitable overlay coatings such as aluminium (Al), Titanium (Ti) and carbon (C). The surface hardening due to implantation is attributed to precipitation hardening or the formation of stable/metastable phase or both. The effect of lithium implantation in aluminium and its alloy on microhardness with increasing ion dose and ion beam energy is also discussed. (author)

  16. Implanted-tritium permeation experiments

    International Nuclear Information System (INIS)

    Longhurst, G.R.; Holland, D.F.; Casper, L.A.; Hsu, P.Y.; Miller, L.G.; Schmunk, R.E.; Watts, K.D.; Wilson, C.J.; Kershner, C.J.; Rogers, M.L.

    1982-04-01

    In fusion reactors, charge exchange neutral atoms of tritium coming from the plasma will be implanted into the first wall and other interior structures. EG and G Idaho is conducting two experiments to determine the magnitude of permeation into the coolant streams and the retention of tritium in those structures. One experiment uses an ion gun to implant deuterium. The ion gun will permit measurements to be made for a variety of implantation energies and fluxes. The second experiment utilizes a fission reactor to generate a tritium implantation flux by the 3 He(n,p) 3 H reaction. This experiment will simulate the fusion reactor radiation environment. We also plan to verify a supporting analytical code development program, in progress, by these experiments

  17. Dental-Implantate und ihre Werkstoffe

    Science.gov (United States)

    Newesely, Heinrich

    1983-07-01

    Some new trends in materials for dental implants, which also effect in the operative techniques and implant design, are described. Advantages and shortcomings of the different material types are exemplified and correlated with their bioinert resp. bioactive functions. The practical interest in metallic implants focussed in titanium resp. oxide ceramics in the ceramic field, whereas the special goal of implant research follows from the improvement of the bioactive principle with loaded calcium phosphate implants.

  18. Biodegradable Implants in Orthopaedics and Traumatology

    OpenAIRE

    YETKIN, Haluk

    2014-01-01

    Biodegradable implants are an alternative to metallic implants and have the advantage of not being necessary to remove once the fracture has healed. Twenty-two patients with fractures were treated with biodegradable implants. There were osteolysis in eleven patients; however, no serious complication was encountered. Although biodegradable implants are expensive, a second surgical procedure to remove the implants is not necessary, relieving the patient of the related costs and risks.

  19. Basics of clinical diagnosis in implant dentistry

    Directory of Open Access Journals (Sweden)

    Manu Rathee

    2015-01-01

    Full Text Available Implant-based prosthetic rehabilitation requires an understanding of associated anatomical structures. The ultimate predictability of an implant site is determined by the existing anatomy as related to dentition and the associated hard and soft tissues. Meticulous clinical assessment helps in determining the suitability of the potential site for implant placement. The purpose of this article is to present the clinical assessment for dental implants' placement to modulate peri-implant tissue characteristics in individual clinical need.

  20. Body Implanted Medical Device Communications

    Science.gov (United States)

    Yazdandoost, Kamya Yekeh; Kohno, Ryuji

    The medical care day by day and more and more is associated with and reliant upon concepts and advances of electronics and electromagnetics. Numerous medical devices are implanted in the body for medical use. Tissue implanted devices are of great interest for wireless medical applications due to the promising of different clinical usage to promote a patient independence. It can be used in hospitals, health care facilities and home to transmit patient measurement data, such as pulse and respiration rates to a nearby receiver, permitting greater patient mobility and increased comfort. As this service permits remote monitoring of several patients simultaneously it could also potentially decrease health care costs. Advancement in radio frequency communications and miniaturization of bioelectronics are supporting medical implant applications. A central component of wireless implanted device is an antenna and there are several issues to consider when designing an in-body antenna, including power consumption, size, frequency, biocompatibility and the unique RF transmission challenges posed by the human body. The radiation characteristics of such devices are important in terms of both safety and performance. The implanted antenna and human body as a medium for wireless communication are discussed over Medical Implant Communications Service (MICS) band in the frequency range of 402-405MHz.

  1. Cochlear implants and medical tourism.

    Science.gov (United States)

    McKinnon, Brian J; Bhatt, Nishant

    2010-09-01

    To compare the costs of medical tourism in cochlear implant surgery performed in India as compared to the United States. In addition, the cost savings of obtaining cochlear implant surgery in India were compare d to those of other surgical interventions obtained as a medical tourist. Searches were conducted on Medline and Google using the search terms: 'medical tourism', 'medical offshoring', 'medical outsourcing', 'cochlear implants' and 'cochlear implantation'. The information regarding cost of medical treatment was obtained from personal communication with individuals familiar with India's cochlear implantation medical tourism industry. The range of cost depended on length of stay as well as the device chosen. Generally the cost, inclusive of travel, surgery and device, was in the range of $21,000-30,000, as compared to a cost range of $40,000-$60,000 in the US. With the escalating cost of healthcare in the United States, it is not surprising that some patients would seek to obtain surgical care overseas at a fraction of the cost. Participants in medical tourism often have financial resources, but lack health insurance coverage. While cardiovascular and orthopedic surgery performed outside the United States in India at centers that cater to medical tourists are often performed at one-quarter to one-third of the cost that would have been paid in the United States, the cost differential for cochlear implants is not nearly as favorable.

  2. Implantation damage in silicon devices

    International Nuclear Information System (INIS)

    Nicholas, K.H.

    1977-01-01

    Ion implantation, is an attractive technique for producing doped layers in silicon devices but the implantation process involves disruption of the lattice and defects are formed, which can degrade device properties. Methods of minimizing such damage are discussed and direct comparisons made between implantation and diffusion techniques in terms of defects in the final devices and the electrical performance of the devices. Defects are produced in the silicon lattice during implantation but they are annealed to form secondary defects even at room temperature. The annealing can be at a low temperature ( 0 C) when migration of defects in silicon in generally small, or at high temperature when they can grow well beyond the implanted region. The defect structures can be complicated by impurity atoms knocked into the silicon from surface layers by the implantation. Defects can also be produced within layers on top of the silicon and these can be very important in device fabrication. In addition to affecting the electrical properties of the final device, defects produced during fabrication may influence the chemical properties of the materials. The use of these properties to improve devices are discussed as well as the degradation they can cause. (author)

  3. The vestibular implant: Quo vadis?

    Directory of Open Access Journals (Sweden)

    Raymond eVan De Berg

    2011-08-01

    Full Text Available AbstractObjective: to assess the progress of the development of the vestibular implant and its feasibility short-term. Data sources: a search was performed in Pubmed, Medline and Embase. Key words used were vestibular prosth* and vestibular implant. The only search limit was language: English or Dutch. Additional sources were medical books, conference lectures and our personal experience with per-operative vestibular stimulation in patients selected for cochlear implantation.Study selection: all studies about the vestibular implant and related topics were included and evaluated by two reviewers. No study was excluded since every study investigated different aspects of the vestibular implant. Data extraction and synthesis: data was extracted by the first author from selected reports, supplemented by additional information, medical books conference lectures. Since each study had its own point of interest with its own outcomes, it was not possible to compare data of different studies. Conclusion: to use a basic vestibular implant in humans seems feasible in the very near future. Investigations show that electric stimulation of the canal nerves induces a nystagmus which corresponds to the plane of the canal which is innervated by the stimulated nerve branch. The brain is able to adapt to a higher baseline stimulation, while still reacting on a dynamic component. The best response will be achieved by a combination of the optimal stimulus (stimulus profile, stimulus location, precompensation, complemented by central vestibular adaptation. The degree of response will probably vary between individuals, depending on pathology and their ability to adapt.

  4. Imaging of common breast implants and implant-related complications: A pictorial essay.

    Science.gov (United States)

    Shah, Amisha T; Jankharia, Bijal B

    2016-01-01

    The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance imaging of silicone breast implants, with its high sensitivity and specificity for detecting implant rupture, is the most reliable modality to asses implant integrity. Whichever imaging modality is used, the overall aim of imaging breast implants is to provide the pertinent information about implant integrity, detect implant failures, and to detect breast conditions unrelated to the implants, such as cancer.

  5. Why are mini-implants lost: the value of the implantation technique!

    Science.gov (United States)

    Romano, Fabio Lourenço; Consolaro, Alberto

    2015-01-01

    The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1) Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2) Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3) Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4) The more precise the lancing procedures, the better the implant placement technique; 5) Self-drilling does not mean higher pressures; 6) Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  6. Why are mini-implants lost: The value of the implantation technique!

    Directory of Open Access Journals (Sweden)

    Fabio Lourenço Romano

    2015-02-01

    Full Text Available The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1 Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2 Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3 Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4 The more precise the lancing procedures, the better the implant placement technique; 5 Self-drilling does not mean higher pressures; 6 Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  7. Imaging of common breast implants and implant-related complications: A pictorial essay

    Directory of Open Access Journals (Sweden)

    Amisha T Shah

    2016-01-01

    Full Text Available The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance imaging of silicone breast implants, with its high sensitivity and specificity for detecting implant rupture, is the most reliable modality to asses implant integrity. Whichever imaging modality is used, the overall aim of imaging breast implants is to provide the pertinent information about implant integrity, detect implant failures, and to detect breast conditions unrelated to the implants, such as cancer.

  8. Implantate in der Augenheilkunde

    Science.gov (United States)

    Dresp, Joachim H.

    Im Bereich der Augenheilkunde findet sich die weltweit am häufigsten ausgeführte chirurgische Massnahme, die operative Behandlung des Grauen Stars: die Katarakt. Bei der Katarakt handelt es sich um eine Eintrübung der natürlichen Augenlinse, die sich je nach Stadium der Erkrankung leicht opak, über milchig bis zu bräunlich präsentiert. Mit dieser Zunahme der Undurchlässigkeit für das sichtbare Licht geht eine Abnahme des Sehvermögens einher, die bis zur totalen Erblindung führen kann. Bedingt durch die sehr eingeschränkten chirurgischen Möglichkeiten in den Ländern der Dritten Welt ist die Katarakt die Erblindungsursache Nummer 1 in der Welt. Ganz im Gegensatz hierzu ist in den industrialisierten Ländern Europas, Amerikas und Asiens die Katarakt-OP die sicherste chirurgische Intervention. In der Augenheilkunde werden Implantate aller drei Aggregatszustände verwendet.

  9. Precision of fit between implant impression coping and implant replica pairs for three implant systems.

    Science.gov (United States)

    Nicoll, Roxanna J; Sun, Albert; Haney, Stephan; Turkyilmaz, Ilser

    2013-01-01

    The fabrication of an accurately fitting implant-supported fixed prosthesis requires multiple steps, the first of which is assembling the impression coping on the implant. An imprecise fit of the impression coping on the implant will cause errors that will be magnified in subsequent steps of prosthesis fabrication. The purpose of this study was to characterize the 3-dimensional (3D) precision of fit between impression coping and implant replica pairs for 3 implant systems. The selected implant systems represent the 3 main joint types used in implant dentistry: external hexagonal, internal trilobe, and internal conical. Ten impression copings and 10 implant replicas from each of the 3 systems, B (Brånemark System), R (NobelReplace Select), and A (NobelActive) were paired. A standardized aluminum test body was luted to each impression coping, and the corresponding implant replica was embedded in a stone base. A coordinate measuring machine was used to quantify the maximum range of displacement in a vertical direction as a function of the tightening force applied to the guide pin. Maximum angular displacement in a horizontal plane was measured as a function of manual clockwise or counterclockwise rotation. Vertical and rotational positioning was analyzed by using 1-way analysis of variance (ANOVA). The Fisher protected least significant difference (PLSD) multiple comparisons test of the means was applied when the F-test in the ANOVA was significant (α=.05). The mean and standard deviation for change in the vertical positioning of impression copings was 4.3 ±2.1 μm for implant system B, 2.8 ±4.2 μm for implant system R, and 20.6 ±8.8 μm for implant system A. The mean and standard deviation for rotational positioning was 3.21 ±0.98 degrees for system B, 2.58 ±1.03 degrees for system R, and 5.30 ±0.79 degrees for system A. The P-value for vertical positioning between groups A and B and between groups A and R was <.001. No significant differences were found for

  10. Falha prematura em implantes orais = Early oral implant failures

    Directory of Open Access Journals (Sweden)

    Fadanelli, Alexandro Bianchi

    2005-01-01

    Full Text Available Atualmente, ainda há uma percentagem significativa de fracassos de implantes na prática clínica, causando transtorno para o profissional e para o paciente. O objetivo deste estudo foi avaliar a bibliografia disponível sobre o assunto, apresentar um caso clínico e discutir os aspectos relacionados aos insucessos na terapia com implantes ocorridos durante o período de osteointegração. A avaliação da literatura mostrou haverem múltiplos fatores possivelmente envolvidos nas falhas de implantes, sendo que através do estudo das falhas pode-se minimizar sua ocorrência

  11. Medical implants and methods of making medical implants

    Science.gov (United States)

    Shaw, Wendy J; Yonker, Clement R; Fulton, John L; Tarasevich, Barbara J; McClain, James B; Taylor, Doug

    2014-09-16

    A medical implant device having a substrate with an oxidized surface and a silane derivative coating covalently bonded to the oxidized surface. A bioactive agent is covalently bonded to the silane derivative coating. An implantable stent device including a stent core having an oxidized surface with a layer of silane derivative covalently bonded thereto. A spacer layer comprising polyethylene glycol (PEG) is covalently bonded to the layer of silane derivative and a protein is covalently bonded to the PEG. A method of making a medical implant device including providing a substrate having a surface, oxidizing the surface and reacting with derivitized silane to form a silane coating covalently bonded to the surface. A bioactive agent is then covalently bonded to the silane coating. In particular instances, an additional coating of bio-absorbable polymer and/or pharmaceutical agent is deposited over the bioactive agent.

  12. An Unusual Bone Loss Around Implants

    Directory of Open Access Journals (Sweden)

    Amirreza Rokn

    2013-01-01

    Full Text Available AbstractPre-implant disease is an inflammatory process, which can affect the surrounding tissues of a functional Osseointegrated implant that is usually as a result of a disequilibrium between the micro-flora and the body defense system.This case reports a 57 years old male with unusual bone loss around dental implants.This was an unusual case of peri-implantitis which occurred only in the implants on one side of the mouth although they all were unloaded implants.

  13. Occlusal considerations for dental implant restorations.

    Science.gov (United States)

    Bergmann, Ranier H

    2014-01-01

    When placed, dental implants are put into an ever-changing oral environment in which teeth can continue to migrate. Yet, the implants themselves are ankylosed. This can lead to occlusal instability. Teeth may continue to erupt, leaving the implants in infraocclusion. Teeth may move mesially away from an implant, requiring modification to close an open contact point. Friction in the connection between teeth and implants can lead to intrusion of teeth and damage to the periodontal attachment apparatus. Implant occlusion with shallow incisal guidance minimizes lateral and tipping forces. Cross-arch stabilization allows the best distribution of occlusal forces. The choice of restorative materials influences long-term occlusal stability.

  14. Current trends in ion implantation

    International Nuclear Information System (INIS)

    Gwilliam, R.M.

    2001-01-01

    As semiconductor device dimensions continue to shrink, the drive beyond 250 nm is creating significant problems for the device processor. In particular, trends toward shallower-junctions, lower thermal budgets and simplified processing steps present severe challenges to ion implantation. In parallel with greater control of the implant process goes the need for a better understanding of the physical processes involved during implantation and subsequent activation annealing. For instance, the need for an understanding of dopant-defect interaction is paramount as defects mediate a number of technologically important phenomena such as transient enhanced diffusion and impurity gettering. This paper will outline the current trends in the ion implantation and some of the challenges it faces in the next decade, as described in the semiconductor roadmap. It will highlight some recent positron annihilation work that has made a contribution to addressing one of these challenges, namely the need for tighter control of implant uniformity and dose. Additionally, some vacancy-mediated processes are described with the implication that these may provide areas in which positron annihilation spectroscopy could make a significant contribution. (orig.)

  15. Composite fibrous glaucoma drainage implant

    Science.gov (United States)

    Klapstova, A.; Horakova, J.; Shynkarenko, A.; Lukas, D.

    2017-10-01

    Glaucoma is a frequent reason of loss vision. It is usually caused by increased intraocular pressure leading to damage of optic nerve head. This work deals with the development of fibrous structure suitable for glaucoma drainage implants (GDI). Commercially produced metallic glaucoma implants are very effective in lowering intraocular pressure. However, these implants may cause adverse events such as damage to adjacent tissue, fibrosis, hypotony or many others [1]. The aim of this study is to reduce undesirable properties of currently produced drains and improve their properties by creating of the composite fibrous drain for achieve a normal intraocular pressure. Two types of electrospinning technologies were used for the production of very small tubular implants. First type was focused for production of outer part of tubular drain and the second type of electrospinning method made the inner part of shape follows the connections of both parts. Complete implant had a special properties suitable for drainage of fluid. Morphological parameters, liquid transport tests and in-vitro cell adhesion tests were detected.

  16. Cranioplasty with individual titanium implants

    Science.gov (United States)

    Mishinov, S.; Stupak, V.; Sadovoy, M.; Mamonova, E.; Koporushko, N.; Larkin, V.; Novokshonov, A.; Dolzhenko, D.; Panchenko, A.; Desyatykh, I.; Krasovsky, I.

    2017-09-01

    Cranioplasty is the second procedure in the history of neurosurgery after trepanation, and it is still relevant despite the development of civilization and progress in medicine. Each cranioplasty operation is unique because there are no two patients with identical defects of the skull bones. The development of Direct Metal Laser Sintering (DMLS) technique opened up the possibility of direct implant printing of titanium, a biocompatible metal used in medicine. This eliminates the need for producing any intermediate products to create the desired implant. We have produced 8 patient-specific titanium implants using this technique for patients who underwent different decompressive cranioectomies associated with bone tumors. Follow-up duration ranged from 6 to 12 months. We observed no implant-related reactions or complications. In all cases of reconstructive neurosurgery we achieved good clinical and aesthetic results. The analysis of the literature and our own experience in three-dimensional modeling, prototyping, and printing suggests that direct laser sintering of titanium is the optimal method to produce biocompatible surgical implants.

  17. Aqueous shunt implantation in glaucoma

    Directory of Open Access Journals (Sweden)

    Jing Wang

    2017-01-01

    Full Text Available Aqueous shunts or glaucoma drainage devices are increasingly utilized in the management of refractory glaucoma. The general design of the most commonly-used shunts is based on the principles of the Molteno implant: ie. a permanent sclerostomy (tube, a predetermined bleb area (plate and diversion of aqueous humour to the equatorial region and away from the limbal subconjunctival space. These three factors make aqueous shunts more resistant to scarring as compared to trabeculectomy. The two most commonly used shunts are the Ahmed Glaucoma Valve, which contains a flow-restrictor, and the non-valved Baervedlt Glaucoma Implant. While the valved implants have a lower tendency to hypotony and related complications, the non-valved implants with larger, more-biocompatible end plate design, achieve lower intraocular pressures with less encapsulation. Non-valved implants require additional suturing techniques to prevent early hypotony and a number of these methods will be described. Although serious shunt-related infection is rare, corneal decompensation and diplopia are small but significant risks.

  18. Capacitive Feedthroughs for Medical Implants.

    Science.gov (United States)

    Grob, Sven; Tass, Peter A; Hauptmann, Christian

    2016-01-01

    Important technological advances in the last decades paved the road to a great success story for electrically stimulating medical implants, including cochlear implants or implants for deep brain stimulation. However, there are still many challenges in reducing side effects and improving functionality and comfort for the patient. Two of the main challenges are the wish for smaller implants on one hand, and the demand for more stimulation channels on the other hand. But these two aims lead to a conflict of interests. This paper presents a novel design for an electrical feedthrough, the so called capacitive feedthrough, which allows both reducing the size, and increasing the number of included channels. Capacitive feedthroughs combine the functionality of a coupling capacitor and an electrical feedthrough within one and the same structure. The paper also discusses the progress and the challenges of the first produced demonstrators. The concept bears a high potential in improving current feedthrough technology, and could be applied on all kinds of electrical medical implants, even if its implementation might be challenging.

  19. A new system of implant abutment connection: how to improve a two piece implant system sealing.

    Science.gov (United States)

    Grecchi, F; DI Girolamo, M; Cura, F; Candotto, V; Carinci, F

    2017-01-01

    Implant dentistry has become one of the most successful dentistry techniques for replacing missing teeth. The success rate of implant dentistry is above 80%. However, peri-implantitis is a later complication of implant dentistry that if untreated, can lead to implant loss. One of the hypotized causes of peri-implantis is the bacterial leakage at the level of implant-abutment connection. Bacterial leakage is favored to the presence of a micro gap at the implant-abutment interface, allowing microorganisms to penetrate and colonize the inner part of the implant leading to biofilm accumulation and consequently to peri-implantitis development. To identify the capability of the implant to protect the internal space from the external environment, the passage of genetically modified Escherichia coli across implant-abutment interface was evaluated. Implants were immerged in a bacterial culture for twenty-four hours and then bacteria amount was measured inside implant-abutment interface with Real-time PCR. Bacteria were detected inside all studied implants, with a median percentage of 9%. The reported results are better to those of previous studies carried out on different implant systems. Until now, none implant-abutment system has been proven to seal the gap between implant and abutment.

  20. Cortical Plasticity after Cochlear Implantation

    DEFF Research Database (Denmark)

    Petersen, Bjørn; Gjedde, Albert; Wallentin, Mikkel

    2013-01-01

    recently implanted adult implant recipients listened to running speech or speech-like noise in four sequential PET sessions at each milestone. CI listeners with postlingual hearing loss showed differential activation of left superior temporal gyrus during speech and speech-like stimuli, unlike CI listeners...... with prelingual hearing loss. Furthermore, Broca's area was activated as an effect of time, but only in CI listeners with postlingual hearing loss. The study demonstrates that adaptation to the cochlear implant is highly related to the history of hearing loss. Speech processing in patients whose hearing loss...... occurred after the acquisition of language involves brain areas associated with speech comprehension, which is not the case for patients whose hearing loss occurred before the acquisition of language. Finally, the findings confirm the key role of Broca's area in restoration of speech perception, but only...

  1. Tinting of intraocular lens implants

    Energy Technology Data Exchange (ETDEWEB)

    Zigman, S.

    1982-06-01

    Intraocular lens (IOL) implants of polymethyl methacrylate (PMMA) lack an important yellow pigment useful as a filter in the visual process and in the protection of the retina from short-wavelength radiant energy. The ability to produce a yellow pigment in the PMMA used in IOL implants by exposure to near-ultraviolet (UV) light was tested. It was found that the highly cross-linked material in Copeland lens blanks was tinted slightly because of this exposure. The absorptive properties of lens blanks treated with near-UV light in this way approached that of the absorptive properties of human lenses. This finding shows that it is possible to alter IOL implants simply so as to induce a pale-yellow pigment in them to improve the visual process and to protect the retinas of IOL users.

  2. MRI of orbital hydroxyapatite implants

    International Nuclear Information System (INIS)

    Flanders, A.E.; De Potter P.; Rao, V.M.; Tom, B.M.; Shields, C.L.; Shields, J.A.

    1996-01-01

    Our aim was to use MRI for the postsurgical assessment of a new form of integrated orbital implant composed of a porous calcium phosphate hydroxyapatite substrate. We studied ten patients 24-74 years of age who underwent enucleation and implantation of a hydroxyapatite ball; 5-13 months after surgery, each patient was examined by spin-echo MRI, with fat suppression and gadolinium enhancement. Fibrovascular ingrowth was demonstrated in all ten patients as areas of enhancement at the periphery of the hydroxyapatite sphere that extended to the center to a variable degree. The radiologist should aware of the MRI appearances of the coralline hydroxyapatite orbital implant since it is now widely used following enucleation. MRI is a useful means to determine successful incorporation of the substrate into the orbital tissues. The normal pattern of contrast enhancement should not be mistaken for recurrent tumor or infection. (orig.)

  3. Tinting of intraocular lens implants

    International Nuclear Information System (INIS)

    Zigman, S.

    1982-01-01

    Intraocular lens (IOL) implants of polymethyl methacrylate (PMMA) lack an important yellow pigment useful as a filter in the visual process and in the protection of the retina from short-wavelength radiant energy. The ability to produce a yellow pigment in the PMMA used in IOL implants by exposure to near-ultraviolet (UV) light was tested. It was found that the highly cross-linked material in Copeland lens blanks was tinted slightly because of this exposure. The absorptive properties of lens blanks treated with near-UV light in this way approached that of the absorptive properties of human lenses. This finding shows that it is possible to alter IOL implants simply so as to induce a pale-yellow pigment in them to improve the visual process and to protect the retinas of IOL users

  4. Implant rehabilitation in bruxism patient

    Science.gov (United States)

    Goiato, Marcelo Coelho; Sonego, Mariana Vilela; dos Santos, Daniela Micheline; da Silva, Emily Vivianne Freitas

    2014-01-01

    A white female patient presented to the university clinic to obtain implant retained prostheses. She had an edentulous maxillary jaw and presented three teeth with poor prognosis (33, 34 and 43). The alveolar bone and the surrounding tissues were healthy. The patient did not report any relevant medical history contraindicating routine dental treatment or implant surgery, but self-reported a dental history of asymptomatic nocturnal bruxism. The treatment plan was set and two Branemark protocols supported by six implants in each arch were installed after a 6-month healing period. A soft occlusal splint was made due to the patient's history of bruxism, and the lack of its use by the patient resulted in an acrylic fracture. The prosthesis was repaired and the importance of using the occlusal splint was restated. In the 4-year follow-up no fractures were reported. PMID:24907215

  5. MR imaging of breast implants.

    Science.gov (United States)

    Gorczyca, D P

    1994-11-01

    MR imaging has proved to be an excellent imaging modality in locating free silicone and evaluating an implant for rupture, with a sensitivity of approximately 94% and specificity of 97%. Silicone has a unique MR resonance frequency and long T1 and T2 relaxation times, which allows several MR sequences to provide excellent diagnostic images. The most commonly used sequences include T2-weighted, STIR, and chemical shift imaging (Figs. 3, 13, and 14). The T2-weighted and STIR sequences are often used in conjunction with chemical water suppression. The most reliable findings on MR images for detection of implant rupture include identification of the collapsed implant shell (linguine sign) and free silicone within the breast parenchyma.

  6. Radioactive implants for medical applications; Radioaktive Implantate fuer medizinische Anwendungen

    Energy Technology Data Exchange (ETDEWEB)

    Schubert, M.

    2008-07-01

    The long-term success of surgery is often diminished by excessive wound healing, which makes another intervention necessary. Locally applied radionuclides with short range radiation can prevent such benign hyperproliferation. As pure electron emitter with a half-life of 14.3 days and a mean energy of 694.9 keV (E{sub max}=1710.48 keV) {sup 32}P is a suitable radionuclide which can be produced from the stable {sup 31}P by the capture of thermal neutrons (1 x 10{sup 14} /s/cm{sup 2}) in a nuclear reactor. After a typical irradiation time (14 days) the ratio of {sup 32}P to {sup 31}P is 1.4 x 10{sup -5} to 1. Implants made of polymer and/or bioabsorbable material functioning as a carrier of the radioactive emitter allow - as opposed to metallic implants - for new applications for this type of radiotherapy. In this thesis a manufacturing method for previously not available organic, radioactive implants has been developed and a corresponding dosimetry system has been established. By means of ion implantation, {sup 32}P ions with up to 180 keV can be shot some 100 nm deep into organic implant materials. For a typical dose (15 Gy over 7 days, 1 mm distance from the implant) an activity of 75 kBq is needed corresponding to 1.3 x 10{sup 11} {sup 32}P ions. The sputter ion gun, which has been optimized for this application, creates an ion beam with high beam current (> 14 {mu}A P{sup -}) and low emittance (< 4 {pi} mm mrad {radical}(MeV)). Because of the good beam quality also small implants (<1 mm{sup 2}) can be manufactured with high efficiency. The unintentionally co-implanted portion of molecules and nuclides of the same mass (e.g. {sup 31}PH, {sup 16}O{sub 2} and {sup 32}S) could be reduced from approximately 500 to 50 by an improvement of the isotope selection at {sup 32}P beam creation. Hence, in comparison with the best hitherto existing implantation methods, the radiation dose of the implant could be reduced by an order of magnitude. With regard to the beta

  7. Surface engineering by ion implantation

    International Nuclear Information System (INIS)

    Nielsen, Bjarne Roger

    1995-01-01

    Awidespread commercial applica tion iof particle accelerators is for ion implantation. Accelerator beams are used for ion implantation into metals, alloying a thin surface layer with foreign atoms to concentrations impossible to achieve by thermal processes, making for dramatic improvements in hardness and in resistance to wear and corrosion. Traditional hardening processes require high temperatures causing deformation; ion implantation on the other hand is a ''cold process'', treating the finished product. The ionimplanted layer is integrated in the substrate, avoiding the risk of cracking and delamination from normal coating processes. Surface properties may be ''engineered'' independently of those of the bulk material; the process does not use environmentally hazardous materials such as chromium in the surface coating. The typical implantation dose required for the optimum surface properties of metals is around 2 x 10 17 ion/cm 2 , a hundred times the typical doses for semiconductor processing. When surface areas of more than a few square centimetres have to be treated, the implanter must therefore be able to produce high beam currents (5 to 10 mA) to obtain an acceptable treatment time. Ion species used include nitrogen, boron, carbon, titanium, chromium and tantalum, and beam energies range from 50 to 200 keV. Since most components are three dimensional, it must be possible to rotate and tilt them in the beam, and control beam position over a large area. Examples of industrial applications are: - surface treatment of prostheses (hip and knee joints) to reduce wear of the moving parts, using biocompatible materials; - ion implantation into high speed ball bearings to protect against the aqueous corrosion in jet engines (important for service helicopters on oil rigs); - hardening of metal forming and cutting tools; - reduction of corrosive wear of plastic moulding tools, which are expensive to produce

  8. Carbon Fiber Biocompatibility for Implants

    Directory of Open Access Journals (Sweden)

    Richard Petersen

    2016-01-01

    Full Text Available Carbon fibers have multiple potential advantages in developing high-strength biomaterials with a density close to bone for better stress transfer and electrical properties that enhance tissue formation. As a breakthrough example in biomaterials, a 1.5 mm diameter bisphenol-epoxy/carbon-fiber-reinforced composite rod was compared for two weeks in a rat tibia model with a similar 1.5 mm diameter titanium-6-4 alloy screw manufactured to retain bone implants. Results showed that carbon-fiber-reinforced composite stimulated osseointegration inside the tibia bone marrow measured as percent bone area (PBA to a great extent when compared to the titanium-6-4 alloy at statistically significant levels. PBA increased significantly with the carbon-fiber composite over the titanium-6-4 alloy for distances from the implant surfaces of 0.1 mm at 77.7% vs. 19.3% (p < 10−8 and 0.8 mm at 41.6% vs. 19.5% (p < 10−4, respectively. The review focuses on carbon fiber properties that increased PBA for enhanced implant osseointegration. Carbon fibers acting as polymer coated electrically conducting micro-biocircuits appear to provide a biocompatible semi-antioxidant property to remove damaging electron free radicals from the surrounding implant surface. Further, carbon fibers by removing excess electrons produced from the cellular mitochondrial electron transport chain during periods of hypoxia perhaps stimulate bone cell recruitment by free-radical chemotactic influences. In addition, well-studied bioorganic cell actin carbon fiber growth would appear to interface in close contact with the carbon-fiber-reinforced composite implant. Resulting subsequent actin carbon fiber/implant carbon fiber contacts then could help in discharging the electron biological overloads through electrochemical gradients to lower negative charges and lower concentration.

  9. Neutrophil Responses to Sterile Implant Materials.

    Directory of Open Access Journals (Sweden)

    Siddharth Jhunjhunwala

    Full Text Available In vivo implantation of sterile materials and devices results in a foreign body immune response leading to fibrosis of implanted material. Neutrophils, one of the first immune cells to be recruited to implantation sites, have been suggested to contribute to the establishment of the inflammatory microenvironment that initiates the fibrotic response. However, the precise numbers and roles of neutrophils in response to implanted devices remains unclear. Using a mouse model of peritoneal microcapsule implantation, we show 30-500 fold increased neutrophil presence in the peritoneal exudates in response to implants. We demonstrate that these neutrophils secrete increased amounts of a variety of inflammatory cytokines and chemokines. Further, we observe that they participate in the foreign body response through the formation of neutrophil extracellular traps (NETs on implant surfaces. Our results provide new insight into neutrophil function during a foreign body response to peritoneal implants which has implications for the development of biologically compatible medical devices.

  10. Fractographic analysis of fractured dental implant components

    Directory of Open Access Journals (Sweden)

    Chih-Ling Chang

    2013-03-01

    Conclusion: To avoid implant fracture, certain underlying mechanical risk factors should be noted such as patients with a habit of bruxism, bridgework with a cantilever design, or two implants installed in a line in the posterior mandible.

  11. Production of amorphous alloys by ion implantation

    International Nuclear Information System (INIS)

    Grant, W.A.; Chadderton, L.T.; Johnson, E.

    1978-01-01

    Recent data are reported on the use of ion implantation to produce amorphous metallic alloys. In particular data on the dose dependence of the crystalline to amorphous transition induced by P + implantation of nickel is presented. (Auth.)

  12. Dental implant surgery: planning and guidance

    International Nuclear Information System (INIS)

    Lobregt, S.; Schillings, J.J.; Vuurberg, E.

    2001-01-01

    A prototype application has been developed for interactive planning of dental implants on the EasyVision workstation. The user is led step by step via virtual positioning of the implant to the design of a customized drill guide. (orig.)

  13. Preparation of targets by ion implantation

    International Nuclear Information System (INIS)

    Santry, D.C.

    1976-01-01

    Various factors are described which are involved in target preparation by direct ion implantation and the limitations and pitfalls of the method are emphasized. Examples are given of experiments for which ion implanted targets are well suited. (author)

  14. Surgical Templates for Dental Implant Positioning; Current ...

    African Journals Online (AJOL)

    prosthodontics; however, designing an implant‑supported prosthesis with function .... template where a provisional fixed restoration bridges the implant site. Pesun and ... in single implant therapy or short‑span implant‑supported prostheses.

  15. Implants in free fibula flap supporting dental rehabilitation - Implant and peri-implant related outcomes of a randomized clinical trial.

    Science.gov (United States)

    Kumar, Vinay V; Ebenezer, Supriya; Kämmerer, Peer W; Jacob, P C; Kuriakose, Moni A; Hedne, Naveen; Wagner, Wilfried; Al-Nawas, Bilal

    2016-11-01

    The objective of this study was to assess the difference in success rates of implants when using two or four implant-supported-overdentures following segmental mandibular reconstruction with fibula free flap. This prospective, parallel designed, randomized clinical study was conducted with 1:1 ratio. At baseline, all participants already had segmental reconstruction of mandible with free fibula flap. The participants were randomized into two groups: Group-I received implant-supported-overdentures on two tissue-level implants and Group-II received implant-supported-overdentures on four tissue-level implants. Success rates of the implants were evaluated at 3 months, 6 months and 12 months following implant loading using marginal bone level changes as well as peri-implant indices (Buser et al., 1990). 52 patients were randomized into two treatment groups (26 each), out of which 18 patients (36 implants) of Group-I and 17 patients (68 implants) of Group-II were evaluated. One implant in Group-I was lost due to infective complications and one patient in the same group had superior barrel necrosis. There was a statistically significant increase at both time points (p = 0.03, p = 0.04 at 6 months, 12 months) in the amount of marginal bone loss in Group-I (0.4 mm, 0.5 mm at 6 months, 12 months) as compared to Group-II (0.1 mm, 0.2 mm at 6 months, 12 months). There were no clinically significant changes peri-implant parameters between both groups. Peri-implant soft tissue hyperplasia was seen in both groups, 32% of implants at 3-months, 26% at 6-months and 3% at 12-months follow-up. The results of this study show that patients with 2-implant-supported-overdentures had higher marginal bone loss as compared to patients with 4-implant-supported-overdentures. There were no clinically significant differences in peri-implant soft tissue factors in patients with 2- or 4-implant-supported-overdentures. Hyperplastic peri-implant tissues are common in the early implant

  16. Implant surface preparation in the surgical treatment of experimental peri-implantitis with autogenous bone graft and ePTFE membrane in cynomolgus monkeys

    DEFF Research Database (Denmark)

    Schou, Søren; Holmstrup, Palle; Jørgensen, Torben

    2003-01-01

    peri-implantitis; treatment; implant surface preparation; nonhuman primates; histology; stereology......peri-implantitis; treatment; implant surface preparation; nonhuman primates; histology; stereology...

  17. Impact of cone-beam computed tomography on implant planning and on prediction of implant size

    Energy Technology Data Exchange (ETDEWEB)

    Pedroso, Ludmila Assuncao de Mello; Silva, Maria Alves Garcia Santos, E-mail: ludmilapedroso@hotmail.com [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Fac. de Odontologia; Garcia, Robson Rodrigues [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Fac. de Odontologia. Dept. de Medicina Oral; Leles, Jose Luiz Rodrigues [Universidade Paulista (UNIP), Goiania, GO (Brazil). Fac. de Odontologia. Dept. de Cirurgia; Leles, Claudio Rodrigues [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Fac. de Odontologia. Dept. de Prevencao e Reabilitacao Oral

    2013-11-15

    The aim was to investigate the impact of cone-beam computed tomography (CBCT) on implant planning and on prediction of final implant size. Consecutive patients referred for implant treatment were submitted to clinical examination, panoramic (PAN) radiography and a CBCT exam. Initial planning of implant length and width was assessed based on clinical and PAN exams, and final planning, on CBCT exam to complement diagnosis. The actual dimensions of the implants placed during surgery were compared with those obtained during initial and final planning, using the McNemmar test (p < 0.05). The final sample comprised 95 implants in 27 patients, distributed over the maxilla and mandible. Agreement in implant length was 50.5% between initial and final planning, and correct prediction of the actual implant length was 40.0% and 69.5%, using PAN and CBCT exams, respectively. Agreement in implant width assessment ranged from 69.5% to 73.7%. A paired comparison of the frequency of changes between initial or final planning and implant placement (McNemmar test) showed greater frequency of changes in initial planning for implant length (p < 0.001), but not for implant width (p = 0.850). The frequency of changes was not influenced by implant location at any stage of implant planning (chi-square test, p > 0.05). It was concluded that CBCT improves the ability of predicting the actual implant length and reduces inaccuracy in surgical dental implant planning. (author)

  18. Implantable Cardiac Pacemakers – 50 Years from the First Implantation

    Directory of Open Access Journals (Sweden)

    Ratko Magjarević

    2010-01-01

    Overview: Development of implantable cardiac pacemaker was enabled by another important invention, the silicon transistor. h ough the invention of suitable lithium cells as appropriate power supply was essential for prolongation of battery life cycle and for increased reliability of pacemakers, main milestones in the development were associated with technological breakthroughs in electronics: from transistors, which introduced such features as small size and low power consumption, to hybrid and integrated circuits, which enabled programmability, microprocessors, which added more options in programming (multiprogrammability, diagnostics and telemetry, and the ICT (information communication technology that enabled physicians remote access to patients and interrogation of their implantable devices. Conclusions: Implantable pacemakers are reliable devices indicated for a wide range of dif erent therapies of cardiac rhythm disorders and heart failure. h ere is still a lot to learn about the physiology of a normal heart and even more about the failing heart. Modern pacemakers provide physicians valuable information from pacemakers’ memory via the built-in telemetry system. h ese information help physicians to better understand pathologic processes within the heart, thus contributing to the development of new ideas for treatment of diseases and for precise tailoring of the therapy to the patient’s needs. Although implantable pacemakers have reached the level of mature technology, they will continue to develop with therapies and diagnostics to facilitate a higher quality of life.

  19. Augmentation Mammaplasty Using Implants: A Review

    Directory of Open Access Journals (Sweden)

    Susumu Takayanagi

    2012-09-01

    Full Text Available One of the techniques for augmentation mammaplasty is the procedure using implants. Even though this technique has been used for many years, there are still several controversial issues to be discussed and overcome for patient safety. In this review article, capsular contracture, leak or rupture of the implants, possible systemic disease, relation with breast cancer, and recent problems with Poly Implant Prothese implants are described and discussed.

  20. Augmentation Mammaplasty Using Implants: A Review

    Directory of Open Access Journals (Sweden)

    Susumu Takayanagi

    2012-09-01

    Full Text Available One of the techniques for augmentation mammaplasty is the procedure using implants. Eventhough this technique has been used for many years, there are still several controversial issuesto be discussed and overcome for patient safety. In this review article, capsular contracture,leak or rupture of the implants, possible systemic disease, relation with breast cancer, andrecent problems with Poly Implant Prothese implants are described and discussed.

  1. Plasma immersion ion implantation into insulating materials

    International Nuclear Information System (INIS)

    Tian Xiubo; Yang Shiqin

    2006-01-01

    Plasma immersion ion implantation (PIII) is an effective surface modification tool. During PIII processes, the objects to be treated are immersed in plasmas and then biased to negative potential. Consequently the plasma sheath forms and ion implantation may be performed. The pre-requirement of plasma implantation is that the object is conductive. So it seems difficult to treat the insulating materials. The paper focuses on the possibilities of plasma implantation into insulting materials and presents some examples. (authors)

  2. Vitamin D deficiency as a risk factor for the development of autoantibodies in patients with ASIA and silicone breast implants: a cohort study and review of the literature.

    Science.gov (United States)

    Colaris, Maartje J L; van der Hulst, Rene R; Tervaert, Jan Willem Cohen

    2017-05-01

    The development of autoimmunity and/or autoimmune diseases is multifactorial. Vitamin D is one of the factors that might play a role. We postulated that both the presence of adjuvants and insufficient levels of vitamin D may result in the development of autoimmunity in patients with autoimmune/inflammatory syndrome induced by adjuvants (ASIA) in relation to silicone implant incompatibility. We measured vitamin D levels in 135 patients with ASIA in relation to silicone implant incompatibility and related findings to the presence of autoantibodies that are commonly used to diagnose systemic autoimmune diseases. Furthermore, we systematically reviewed the literature regarding vitamin D deficiency as a risk factor for the development of autoantibodies. Vitamin D measurements were available for analysis in 131 of 135 patients with ASIA in relation to SIIS. Twenty-three patients (18%) tested positive for autoantibodies, from which 18 patients (78%) had either a vitamin D deficiency or insufficiency (median vitamin D level 60.5 mmol/L), whereas five patients (22%) had sufficient vitamin D levels. The risk to develop autoantibodies was significantly increased in vitamin D deficient and/or insufficient patients [RR 3.14; 95% CI, 1.24-7.95; p = 0.009]. Reviewed literature suggested an association between vitamin D levels and the presence and/or titer levels of autoantibodies in different autoimmune diseases. From our current study and from our review of the literature, we conclude that vitamin D deficiency is related to the presence of autoantibodies. Whether vitamin D supplementation results in a decrease of autoimmunity needs to be studied prospectively.

  3. Influence of different implant materials on the primary stability of orthodontic mini-implants

    OpenAIRE

    Chin-Yun Pan; Szu-Ting Chou; Yu-Chuan Tseng; Yi-Hsin Yang; Chao-Yi Wu; Ting-Hsun Lan; Pao-Hsin Liu; Hong-Po Chang

    2012-01-01

    This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm). The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm) and stainless steel mini-implants 10 mm in length. The mini-implants w...

  4. Scalloped Implant-Abutment Connection Compared to Conventional Flat Implant-Abutment Connection

    DEFF Research Database (Denmark)

    Starch-Jensen, Thomas; Christensen, Ann-Eva; Lorenzen, Henning

    2017-01-01

    OBJECTIVES: The objective was to test the hypothesis of no difference in implant treatment outcome after installation of implants with a scalloped implant-abutment connection compared to a flat implant-abutment connection. MATERIAL AND METHODS: A MEDLINE (PubMed), Embase and Cochrane library search......-abutment connection. There were no significant differences between the two treatment modalities regarding professional or patient-reported outcome measures. Meta-analysis disclosed a mean difference of peri-implant marginal bone loss of 1.56 mm (confidence interval: 0.87 to 2.25), indicating significant more bone...... loss around implants with a scalloped implant-abutment connection. CONCLUSIONS: A scalloped implant-abutment connection seems to be associated with higher peri-implant marginal bone loss compared to a flat implant-abutment connection. Therefore, the hypothesis of the present systematic review must...

  5. [The elementary discussion on digital implant dentistry].

    Science.gov (United States)

    Su, Y C

    2016-04-09

    It is a digital age today. Exposed to all kinds of digital products in many fields. Certainly, implant dentistry is not exception. Digitalization could improve the outcomes and could decrease the complications of implant dentistry. This paper introduces the concepts, definitions, advantages, disadvantages, limitations and errors of digital implant dentistry.

  6. Active implants and scaffolds for tissue regeneration

    CERN Document Server

    Zilberman, Meital

    2011-01-01

    Active implants are actually drug or protein-eluting implants that induce healing effects, in addition to their regular task, such as support. This book gives a broad overview of biomaterial platforms used as basic elements of drug-eluting implants.

  7. Surgical Templates for Dental Implant Positioning; Current ...

    African Journals Online (AJOL)

    Since the mid‑20th century, there has been an increase in interest in the implant process for the replacement of missing teeth. Branemark ... Ideal placement of the implant facilitates the establishment of favorable forces on the implants and the prosthetic component as well as ensures an aesthetic outcome. Therefore, it is ...

  8. The endometrial factor in human embryo implantation

    NARCIS (Netherlands)

    Boomsma, C.M.

    2009-01-01

    The studies presented in this thesis aimed to explore the role of the endometrium in the implantation process. At present, embryo implantation is the major rate-limiting step for success in fertility treatment. Clinicians have sought to develop clinical interventions aimed at enhancing implantation

  9. Macro design morphology of endosseous dental implants.

    Science.gov (United States)

    Sahiwal, Indira G; Woody, Ronald D; Benson, Byron W; Guillen, Guillermo E

    2002-05-01

    The identification of dental implant bodies in patients without available records is a considerable problem due to increased patient mobility and to the large number of implant systems with different designs. The purpose of this study was to document the designs of selected implants to help clinicians identify these implants from their radiographic images. More than 50 implant manufacturers were contacted and asked to provide implants with dimensions as close as possible to 3.75 mm (diameter) x 10 mm (length). Forty-four implants were donated, separated into threaded and non-threaded categories, and further sorted into tapered and non-tapered categories. The implants were examined visually, and features on the entire circumference and length of each implant were recorded and categorized as coronal, midbody, or apical. A series of tables describe the 44 implants according to coronal, midbody, and apical features. The results of this project offer dentists basic knowledge of the design of selected dental implants. Such knowledge can aid the radiographic identification of these implants.

  10. Imaging of common breast implants and implant-related complications: A pictorial essay

    OpenAIRE

    Shah, Amisha T; Jankharia, Bijal B

    2016-01-01

    The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance i...

  11. Primary prevention of peri-implantitis: Managing peri-implant mucositis

    OpenAIRE

    Jepsen, Søren; Berglundh, Tord; Genco, Robert; Aass, Anne Merete; Demirel, Korkud; Derks, Jan; Figuero, Elena; Giovannoli, Jean Louis; Goldstein, Moshe; LAMBERT, France; Ortiz-Vigon, Alberto; Polyzois, Ioannis; Salvi, Giovanni; Schwarz, Frank; Serino, Giovanni

    2015-01-01

    Abstract AIMS: Over the past decades, the placement of dental implants has become a routine procedure in the oral rehabilitation of fully and partially edentulous patients. However, the number of patients/implants affected by peri-implant diseases is increasing. As there are--in contrast to periodontitis--at present no established and predictable concepts for the treatment of peri-implantitis, primary prevention is of key importance. The management of peri-implant mucositis is considere...

  12. Cochlear implant after bacterial meningitis.

    Science.gov (United States)

    Bille, Jesper; Ovesen, Therese

    2014-06-01

    The aim of this retrospective case study at a tertiary referral center was to investigate the outcome of cochlear implantation (CI) in children with sensorineural hearing loss due to meningitis compared to CI in children with deafness due to other reasons. This post-meningial group (PMG) consisted of 22 children undergoing CI due to deafness induced by meningitis, between December 1996 and January 2012. Five children had bilateral simultaneous implantation. None was excluded and the children were followed for at least 3 years. Operations were carried out by one of two surgeons using similar techniques in all cases. Each patient from the PMG was matched 2:1 with children having implantation for other reasons according to age and follow up (control group). Overall, the median category of auditory performance (CAP) and speech intelligibility rating (SIR) score were not statistically significantly different between the two groups. The presence of additional central nervous system (CNS) disorders (post-meningeal sequelae), however, correlated significantly with poorer outcome CI was a safe procedure without surgical complications in the present study. It is possible to restore auditory capacity and speech performance to a degree comparable to children undergoing implantation for other reasons. A statistically important variable is secondary CNS involvement. The rehabilitation program after CI should be adjusted according to these additional handicaps. It is recommended to screen meningitis patients as fast as possible to identify those with hearing loss and initiate treatment with hearing aids or CI. © 2013 The Authors. Pediatrics International © 2013 Japan Pediatric Society.

  13. Annealing of ion implanted silicon

    International Nuclear Information System (INIS)

    Chivers, D.; Smith, B.J.; Stephen, J.; Fisher, M.

    1980-09-01

    The newer uses of ion implantation require a higher dose rate. This has led to the introduction of high beam current implanters; the wafers move in front of a stationary beam to give a scanning effect. This can lead to non-uniform heating of the wafer. Variations in the sheet resistance of the layers can be very non-uniform following thermal annealing. Non-uniformity in the effective doping both over a single wafer and from one wafer to another, can affect the usefulness of ion implantation in high dose rate applications. Experiments to determine the extent of non-uniformity in sheet resistance, and to see if it is correlated to the annealing scheme have been carried out. Details of the implantation parameters are given. It was found that best results were obtained when layers were annealed at the maximum possible temperature. For arsenic, phosphorus and antimony layers, improvements were observed up to 1200 0 C and boron up to 950 0 C. Usually, it is best to heat the layer directly to the maximum temperature to produce the most uniform layer; with phosphorus layers however it is better to pre-heat to 1050 0 C. (U.K.)

  14. Implantation of boron in silicon

    International Nuclear Information System (INIS)

    Hofker, W.K.

    1975-01-01

    The distribution versus depth of boron implanted in silicon and the corresponding electrical activity obtained after annealing are studied. The boron distributions are measured by secondary-ion mass spectrometry. Boron distributions implanted at energies in the range from 30 keV to 800 keV in amorphous and polycrystalline silicon are analysed. Moments of these distributions are determined by a curve-fitting programme and compared with moments calculated by Winterbon. Boron distributions obtained by implantations along a dense crystallographic direction in monocrystalline silicon are found to have penetrating tails. After investigation of some possible mechanisms of tail formation it is concluded that the tails are due to channelling. It was found that the behaviour of boron during annealing is determined by the properties of three boron fractions consisting of precipitated boron, interstitial boron and substitutional boron. The electrical activity of the boron versus depth is found to be consistent with the three boron fractions. A peculiar redistribution of boron is found which is induced by the implantation of a high dose of heavy ions and subsequent annealing. Different mechanisms which may cause the observed effects, such as thermal diffusion which is influenced by lattice strain and damage, are discussed. (Auth.)

  15. [Dental implant restoration abutment selection].

    Science.gov (United States)

    Bin, Shi; Hao, Zeng

    2017-04-01

    An increasing number of implant restoration abutment types are produced with the rapid development of dental implantology. Although various abutments can meet different clinical demands, the selection of the appropriate abutment is both difficult and confusing. This article aims to help clinicians select the appropriate abutment by describing abutment design, types, and selection criteria.

  16. Reading skills after cochlear implantation

    NARCIS (Netherlands)

    Vermeulen, A.M.

    2007-01-01

    It has frequently been found that profoundly deaf children with conventional hearing aids have difficulties with the comprehension of written text. Cochlear Implants (CIs) were expected to enhance the reading comprehension of these profoundly deaf children because they provide auditory access to

  17. Advancing Binaural Cochlear Implant Technology

    Directory of Open Access Journals (Sweden)

    Mathias Dietz

    2015-12-01

    Full Text Available This special issue contains a collection of 13 papers highlighting the collaborative research and engineering project entitled Advancing Binaural Cochlear Implant Technology—ABCIT—as well as research spin-offs from the project. In this introductory editorial, a brief history of the project is provided, alongside an overview of the studies.

  18. Cochlear implant: the family's perspective.

    Science.gov (United States)

    Vieira, Sheila de Souza; Dupas, Giselle; Chiari, Brasilia Maria

    2018-07-01

    To understand the family's experience of a child who uses a cochlear implant (CI). Specifically, to identify the difficulties, changes, and feelings entailed by deafness and the use of the CI; the coping strategies; and to understand the role of the family for the child with a CI. Qualitative research, using Symbolic Interactionism and Straussian Grounded Theory as the theoretical and methodological frameworks, respectively. Data collection instrument: semi-structured interview. A total of 9 families (32 individuals) participated in the study. The children's ages ranged from 6 to 11 years old (mean = 8.9 years old). Their experience is described in the following categories: Having to fight for results, Coping with difficult situations, Recognizing that you are not alone, Learning to overcome, and Having one's life restored by the implant. Cochlear implantation changes the direction of the child and the family's life by restoring the child's opportunity to hear and to obtain good results in her personal, social, and academic development. Even after implantation, the child continues to experience difficulties and requires the family's mobilization in order to be successful. The family is the principal actor in the process of the child's rehabilitation.

  19. Usher syndrome and cochlear implantation.

    Science.gov (United States)

    Loundon, Natalie; Marlin, Sandrine; Busquet, Denise; Denoyelle, Françoise; Roger, Gilles; Renaud, Francis; Garabedian, Erea Noel

    2003-03-01

    To evaluate the symptoms leading to diagnosis and the quality of rehabilitation after cochlear implantation in Usher syndrome. Retrospective cohort study. ENT department of a tertiary referral hospital. Among 210 patients given an implantation in the Ear, Nose, and Throat department, 185 were congenitally deaf and 13 had Usher syndrome (7.0%). Five had a family history of Usher, and eight were sporadic cases. Eleven cases were Usher type I, one was Usher type III, and one was not classified. The age at implantation ranged from 18 months to 44 years (mean, 6 years 1 month). The mean follow-up was 52 months (range, 9 months to 9 years). All patients had audiophonological and clinical examination, computed tomography scan of the temporal bones, ophthalmologic examination with fundoscopy, and an electroretinogram. Cerebral magnetic resonance imaging and vestibular examination were performed in 9 of 13 and 10 of 13 cases, respectively. Logopedic outcome measured preimplant and postimplant closed- and open-set word recognition and oral expression at follow-up. The most frequent initial sign of Usher syndrome was delayed walking, with a mean age of 20 months. Among the 172 other congenitally deaf children with implants, when deafness was not associated with other neurologic disorders, the mean age at walking was 14 months (p < 0.001). The fundoscopy was always abnormal after the age of 5 years, and the electroretinogram was abnormal in all cases. Vestibular function was abnormal in all but one case (nonclassified). The computed tomography scan and the magnetic resonance imaging were always normal. Logopedic results with cochlear implants showed good perception skills in all but one case. The best perceptive results were obtained in children implanted before the age of 9 years. Oral language had significantly progressed in 9 of 13 at follow-up. There was no relation between the visual acuity and the logopedic results. The earliest clinical sign associated with deafness

  20. Failure analysis of fractured dental zirconia implants.

    Science.gov (United States)

    Gahlert, M; Burtscher, D; Grunert, I; Kniha, H; Steinhauser, E

    2012-03-01

    The purpose of the present study was the macroscopic and microscopic failure analysis of fractured zirconia dental implants. Thirteen fractured one-piece zirconia implants (Z-Look3) out of 170 inserted implants with an average in situ period of 36.75±5.34 months (range from 20 to 56 months, median 38 months) were prepared for macroscopic and microscopic (scanning electron microscopy [SEM]) failure analysis. These 170 implants were inserted in 79 patients. The patient histories were compared with fracture incidences to identify the reasons for the failure of the implants. Twelve of these fractured implants had a diameter of 3.25 mm and one implant had a diameter of 4 mm. All fractured implants were located in the anterior side of the maxilla and mandibula. The patient with the fracture of the 4 mm diameter implant was adversely affected by strong bruxism. By failure analysis (SEM), it could be demonstrated that in all cases, mechanical overloading caused the fracture of the implants. Inhomogeneities and internal defects of the ceramic material could be excluded, but notches and scratches due to sandblasting of the surface led to local stress concentrations that led to the mentioned mechanical overloading by bending loads. The present study identified a fracture rate of nearly 10% within a follow-up period of 36.75 months after prosthetic loading. Ninety-two per cent of the fractured implants were so-called diameter reduced implants (diameter 3.25 mm). These diameter reduced implants cannot be recommended for further clinical use. Improvement of the ceramic material and modification of the implant geometry has to be carried out to reduce the failure rate of small-sized ceramic implants. Nevertheless, due to the lack of appropriate laboratory testing, only clinical studies will demonstrate clearly whether and how far the failure rate can be reduced. © 2011 John Wiley & Sons A/S.

  1. Effectiveness of Implant Therapy Analyzed in a Swedish Population: Prevalence of Peri-implantitis.

    Science.gov (United States)

    Derks, J; Schaller, D; Håkansson, J; Wennström, J L; Tomasi, C; Berglundh, T

    2016-01-01

    Peri-implantitis is an inflammatory disease affecting soft and hard tissues surrounding dental implants. As the global number of individuals that undergo restorative therapy through dental implants increases, peri-implantitis is considered as a major and growing problem in dentistry. A randomly selected sample of 588 patients who all had received implant-supported therapy 9 y earlier was clinically and radiographically examined. Prevalence of peri-implantitis was assessed and risk indicators were identified by multilevel regression analysis. Forty-five percent of all patients presented with peri-implantitis (bleeding on probing/suppuration and bone loss >0.5 mm). Moderate/severe peri-implantitis (bleeding on probing/suppuration and bone loss >2 mm) was diagnosed in 14.5%. Patients with periodontitis and with ≥4 implants, as well as implants of certain brands and prosthetic therapy delivered by general practitioners, exhibited higher odds ratios for moderate/severe peri-implantitis. Similarly, higher odds ratios were identified for implants installed in the mandible and with crown restoration margins positioned ≤1.5 mm from the crestal bone at baseline. It is suggested that peri-implantitis is a common condition and that several patient- and implant-related factors influence the risk for moderate/severe peri-implantitis (ClinicalTrials.gov NCT01825772). © International & American Associations for Dental Research 2015.

  2. He reemission implanted in metals

    International Nuclear Information System (INIS)

    Tanabe, T.

    2014-01-01

    Highlights: • Observation of He reemission of various metals under He + implantation at wide temperature range. • Materials examined are aluminum (Al), Nickel (Ni) and molybdenum (Mo). • He reemission is quite temperature dependent and different with materials. • Three metals show similar dependence on temperature normalized with respective melting point. • He reemission is successfully correlated with He behavior in metals. - Abstract: Helium (He) reemission of Al, Ni and Mo under energetic He implantation (10–30 keV) in wide temperature range is studied to understand behavior of implanted He in correlation with structure changes. The reemission behavior is categorized into 4 different temperature ranges with the normalized temperature (T m ) to the melting point of each metal. At elevated temperatures (well above ∼0.6 T m ), interstitial He atoms and/or He-vacancy (ies) clusters can migrate remaining no structure change and showing smooth reemission without any burst. Between ∼0.25 and 0.6 T m , He reemission always accompanies significant structure modification. For ∼04–0.6 T m , implanted He coalesce to make bubbles and the bubbles can move to the surface. Bubble migration accompanies materials flow to the surface resulting in fuzz surface or columnar structure, depending on implantation flux. Slower bubble motion at ∼0.25–0.4 prohibits the material migration. Instead the bubbles coalesce to grow large and multi-layered blistering appears as periodic reemission behavior. Below ∼0.25 T m , He migration is too slow for bubbles to grow large, but bubble density increases up to a certain fluence, where neighboring bubbles start to coalesce. Accordingly, He release is mostly caused by mechanical failure or blister rapture. With increasing fluence, all defects (bubbles and dislocation loops) tangle or inter connected with neighboring defects and accordingly He migration to the surface along the tangled or connected defects is enhanced

  3. [Cochlear implant treatment in Germany].

    Science.gov (United States)

    Jacob, R; Stelzig, Y

    2013-01-01

    Restoration of impaired auditory function through cochlear implant is possible, with high reliably and great success. Nevertheless, there are regular disputes between patients and insurance companies due to high costs. In Germany, approx. 1.9 Mio. people are severely hearing impaired. It can be estimated that for adequate hearing rehabilitation about 30,000 cochlear implants/year are necessary. Currently, less than 10% of those affected are offered cochlear implant. A handicap is defined if there is deviation from normal hearing for more than 6 months. This sets a time frame for the supply with cochlear implant after sudden deafness. The professional code requires to advice all medical options to a person seeking help for hearing loss. This includes benefit-risk consideration. At this point, the economic aspect plays no role. The indication for medical treatment is only subject to the treating physician and should not be modified by non-physicians or organizations. It should be noted that a supply of hearing aids is qualitatively different to the help from a cochlear implant, which provides a restoration of lost function. In social law (SGB V and IX) doctors are requested to advise and recommend all measures which contribute to normal hearing (both sides). This indicates that doctors may be prosecuted for not offering help when medically possible, just because health insurance employees did not approve the cost balance. The current situation, with insufficient medical care for the hearing impaired, needs clarifying. To do this, patients, health insurance companies, the political institutions, legislation and professional societies need to accept their responsibilities.

  4. Peri-implant esthetics assessment and management

    Science.gov (United States)

    Balasubramaniam, Aarthi S.; Raja, Sunitha V.; Thomas, Libby John

    2013-01-01

    Providing an esthetic restoration in the anterior region of the mouth has been the basis of peri-implant esthetics. To achieve optimal esthetics, in implant supported restorations, various patient and tooth related factors have to be taken into consideration. Peri-implant plastic surgery has been adopted to improve the soft tissue and hard tissue profiles, during and after implant placement. The various factors and the procedures related to enhancement of peri-implant esthetics have been discussed in this review article. PMID:23878557

  5. Structural-chemical characteristics of implanted metals

    International Nuclear Information System (INIS)

    Kozejkin, B.V.; Pavlov, P.V.; Pitirimova, E.A.; Frolov, A.I.

    1988-01-01

    Corrosion and structural characteristics of metallic layers implanted by ions of chemically active impurities and noble gases are studied. Dependence of experimental results on parameters of initial materials and technological conditions of implantation is established. In studying corrosion characteristics of implanted metals a strong dependence of chemical passivation effect on technological conditions of ion-implantation and structure of initial material is stated. On the basis of developed mathematical model of chemical passivation effect it is shown that increase of corrosion characteristics of implanted metals is defined by superposition of surface and volumetric mechanisms

  6. Current Concepts in Restorative Implant Dentistry

    Institute of Scientific and Technical Information of China (English)

    Prof.Marchack

    2009-01-01

    Patients today are incteasingly aware of dental implants.and their expectations are for esthetically and functionally pleasingimplant restorations that mimic natural teeth.This presentation will give both the experienced and novice practitioner a better understand-ing of how restorative implant dentistry has evolved.Treatment planning and restorative options for single implants.multiple implants andfully edentulons arches will be discussed,and the use of modern materials and CADCAM technology in fabricating the most contemporaryfixed implant supported prostheses will be demonstrated.

  7. Poly Implants Prosthèse Breast Implants: A Case Series and Review of the Literature.

    Science.gov (United States)

    Klein, Doron; Hadad, Eran; Wiser, Itay; Wolf, Omer; Itzhaki Shapira, Ortal; Fucks, Shir; Heller, Lior

    2018-01-01

    Silicone breast implants from the French manufacturer Poly Implants Prosthèse (PIP) were recalled from the European market after the French regulator has revealed the implants contain non-medical-grade silicone filler. In December 2011, following a large increase in reported rupture rate and a possible cancer risk, the French Ministry of Health recommended consideration of the PIP explantation, regardless of their condition. In 2012, the Israel Ministry of Health recommended to replace the implants only upon suspected implant rupture. The aims of this study were to characterize breast-augmented Israeli patients with PIP implants, compare their outcomes with those of breast-augmented patients with different implant types, and review the current PIP literature. Breast-augmented patients who underwent an elective breast implant exchange in Israel between January 2011 and January 2017 were included in the study. Data were collected from electronic and physical medical files. There were 73 breast-augmented female patients with 146 PIP breast implants included in this study. Average implant age was 6.7 ± 2.79 years. Mean implant size was 342.8 ± 52.9 mL. Fourteen women (19 implants [16%]) had a high-grade capsular contracture (Baker grade 3-4). During exchange, 28 implants were found to be ruptured (19.2%). Less than 10 years following breast augmentation, PIP implants demonstrated higher rupture rate compared with other implants. Our data are comparable to overall available rupture rate. Among patients with definitive rupture diagnosis, an elective implant removal should be recommended. In cases of undamaged implants, plastic surgeons should also seriously consider PIP implant explantation. When the patient does not desire to remove the implant, an annual physical examination and breast ultrasound are recommended, beginning a year after augmentation.

  8. [Clinical application of individualized three-dimensional printing implant template in multi-tooth dental implantation].

    Science.gov (United States)

    Wang, Lie; Chen, Zhi-Yuan; Liu, Rong; Zeng, Hao

    2017-08-01

    To study the value and satisfaction of three-dimensional printing implant template and conventional implant template in multi-tooth dental implantation. Thirty cases (83 teeth) with missing teeth needing to be implanted were randomly divided into conventional implant template group (CIT group, 15 cases, 42 teeth) and 3D printing implant template group (TDPIT group, 15 cases, 41 teeth). Patients in CIT group were operated by using conventional implant template, while patients in TDPIT group were operated by using three-dimensional printing implant template. The differences of implant neck and tip deviation, implant angle deviation and angle satisfaction between the two groups were compared. The difference of probing depth and bone resorption of implant were compared 1 year after operation between the two groups. The difference of success rate and satisfaction of dental implantation were compared 1 year after operation between the two groups. SPSS19.0 software package was used for statistical analysis. The deviation direction of the neck and the tip in disto-mesial, bucco-palatal, vertical direction and angle of implants in disto-mesial and bucco-palatal direction in TDPIT group were significantly lower than in CIT group (P0.05). The difference of the cumulative success rate in dental implantation at 3 months and 6 months between the two groups were not significant (P>0.05), but the cumulative success rate of TDPIT group was significantly higher than CIT group at 9 months and 1 year (90.48% vs 100%,P=0.043). The patients' satisfaction rate of dental implantation in TDPIT group was significantly higher than in CIT group (86.67% vs 53.33%, P=0.046). Using three-dimensional printing implant template can obtain better accuracy of implant, higher implant success rate and better patients' satisfaction than using conventional implant template. It is suitable for clinical application.

  9. Ion implantation and bio-compatibility

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Yoshiaki; Kusakabe, Masahiro [Sony Corp., Tokyo (Japan). Corporate Research Labs.; Iwaki, Masaya

    1992-07-01

    Surface modification of polymers by ion implantation has been carried out to control surface properties such as conductivity, wettability, blood and tissue compatibility. Ion implantation into silicone rubber, polystyrene and segmented polyurethane was performed at 150 keV with doses ranging from 1 x 10[sup 15] to 3 x 10[sup 17] ions/cm[sup 2] to improve bio-compatibility. The platelet accumulation on ion implanted silicone rubber decreased and non-thrombogenicity of ion implanted specimens were improved. The ion implanted polystyrene and segmented polyurethane have been found to exhibit remarkably higher adhesion and spreading of endothelial cells compared to the non-implanted case. It is concluded that ion implantation into polymers is effective in controlling their bio-compatibility. (author).

  10. Congenitally Deafblind Children and Cochlear Implants

    DEFF Research Database (Denmark)

    Dammeyer, Jesper Herup

    2008-01-01

    There has been much research conducted demonstrating the positive benefits of cochlear implantation (CI) in children who are deaf. Research on cochlear implantation in children who are both deaf and blind, however, is lacking. The purpose of this article is to present a study of 5 congenitally...... deafblind children who received cochlear implants between 2.2 and 4.2 years of age.  Ratings of video observations were used to measure the children's early communication development with and without the use of their cochlear implants. In addition, parental interviews were used to assess the benefits...... parents perceived regarding their children's cochlear implants. Two examples are included in this article to illustrate the parents' perspectives about cochlear implantation in their deafblind children. Benefits of cochlear implantation in this cohort of children included improved attention and emotional...

  11. Dynamics of bone graft healing around implants

    Directory of Open Access Journals (Sweden)

    Narayan Venkataraman

    2015-01-01

    A few questions arise pertaining to the use of bone grafts along with implants are whether these are successful in approximation with implant. Do they accelerate bone regeneration? Are all defects ultimately regenerated with new viable bone? Is the bone graft completely resorbed or integrated in new bone? Does the implant surface characteristic positively affect osseointegration when used with a bone graft? What type of graft and implant surface can be used that will have a positive effect on the healing type and time? Finally, what are the dynamics of bone graft healing around an implant? This review discusses the cellular and molecular mechanisms of bone graft healing in general and in vicinity of another foreign, avascular body, namely the implant surface, and further, the role of bone grafts in osseointegration and/or clinical success of the implants.

  12. Magnetic resonance imaging of breast implants.

    Science.gov (United States)

    Shah, Mala; Tanna, Neil; Margolies, Laurie

    2014-12-01

    Silicone breast implants have significantly evolved since their introduction half a century ago, yet implant rupture remains a common and expected complication, especially in patients with earlier-generation implants. Magnetic resonance imaging is the primary modality for assessing the integrity of silicone implants and has excellent sensitivity and specificity, and the Food and Drug Administration currently recommends periodic magnetic resonance imaging screening for silent silicone breast implant rupture. Familiarity with the types of silicone implants and potential complications is essential for the radiologist. Signs of intracapsular rupture include the noose, droplet, subcapsular line, and linguine signs. Signs of extracapsular rupture include herniation of silicone with a capsular defect and extruded silicone material. Specific sequences including water and silicone suppression are essential for distinguishing rupture from other pathologies and artifacts. Magnetic resonance imaging provides valuable information about the integrity of silicone implants and associated complications.

  13. Surface modification of implants in long bone.

    Science.gov (United States)

    Förster, Yvonne; Rentsch, Claudia; Schneiders, Wolfgang; Bernhardt, Ricardo; Simon, Jan C; Worch, Hartmut; Rammelt, Stefan

    2012-01-01

    Coatings of orthopedic implants are investigated to improve the osteoinductive and osteoconductive properties of the implant surfaces and thus to enhance periimplant bone formation. By applying coatings that mimic the extracellular matrix a favorable environment for osteoblasts, osteoclasts and their progenitor cells is provided to promote early and strong fixation of implants. It is known that the early bone ongrowth increases primary implant fixation and reduces the risk of implant failure. This review presents an overview of coating titanium and hydroxyapatite implants with components of the extracellular matrix like collagen type I, chondroitin sulfate and RGD peptide in different small and large animal models. The influence of these components on cells, the inflammation process, new bone formation and bone/implant contact is summarized.

  14. Successful Rehabilitation of Partial Edentulous Maxilla and Mandible with New Type of Implants: Molecular Precision Implants

    Directory of Open Access Journals (Sweden)

    Matteo Danza

    2014-01-01

    Full Text Available The extraction of teeth results in rapid bone resorption both vertically and horizontally in the first month. The loss of alveolar ridge reduces the chance of implant rehabilitation. Atraumatic extraction, implant placement in extraction socket, and an immediate prosthesis have been proposed as alternative therapies to maintain the volume and contours tissue and reduce time and cost of treatment. The immediate load of implants is a universally practiced procedure; nevertheless a successful procedure requires expertise in both the clinical and the reconstructive stages using a solid implant system. Excellent primary stability and high bone-implant contact are only minimal requirements for any type of implant procedure. In this paper we present a case report using a new type of implants. The new type of implants, due to its sophisticated control system of production, provides to the implantologist a safe and reliable implant, with a macromorphology designed to ensure a close contact with the surrounding bone.

  15. Does the number of implants have any relation with peri-implant disease?

    Directory of Open Access Journals (Sweden)

    Bernardo Born PASSONI

    2014-10-01

    Full Text Available Objective: The aim of this study was to evaluate the relationship between the number of pillar implants of implant-supported fixed prostheses and the prevalence of periimplant disease. Material and Methods: Clinical and radiographic data were obtained for the evaluation. The sample consisted of 32 patients with implant-supported fixed prostheses in function for at least one year. A total of 161 implants were evaluated. Two groups were formed according to the number of implants: G1 ≤5 implants and G2 >5 implants. Data collection included modified plaque index (MPi, bleeding on probing (BOP, probing depth (PD, width of keratinized mucosa (KM and radiographic bone loss (BL. Clinical and radiographic data were grouped for each implant in order to conduct the diagnosis of mucositis or peri-implantitis. Results: Clinical parameters were compared between groups using Student’s t test for numeric variables (KM, PD and BL and Mann-Whitney test for categorical variables (MPi and BOP. KM and BL showed statistically significant differences between both groups (p<0.001. Implants from G1 – 19 (20.43% – compared with G2 – 26 (38.24% – showed statistically significant differences regarding the prevalence of peri-implantitis (p=0.0210. Conclusion: It seems that more than 5 implants in total fixed rehabilitations increase bone loss and consequently the prevalence of implants with periimplantitis. Notwithstanding, the number of implants does not have any influence on the prevalence of mucositis.

  16. Comparative silicone breast implant evaluation using mammography, sonography, and magnetic resonance imaging: experience with 59 implants.

    Science.gov (United States)

    Ahn, C Y; DeBruhl, N D; Gorczyca, D P; Shaw, W W; Bassett, L W

    1994-10-01

    With the current controversy regarding the safety of silicone implants, the detection and evaluation of implant rupture are causing concern for both plastic surgeons and patients. Our study obtained comparative value analysis of mammography, sonography, and magnetic resonance imaging (MRI) in the detection of silicone implant rupture. Twenty-nine symptomatic patients (total of 59 silicone implants) were entered into the study. Intraoperative findings revealed 21 ruptured implants (36 percent). During physical examination, a positive "squeeze test" was highly suggestive of implant rupture. Mammograms were obtained of 51 implants (sensitivity 11 percent, specificity 89 percent). Sonography was performed on 57 implants (sensitivity 70 percent, specificity 92 percent). MRI was performed on 55 implants (sensitivity 81 percent, specificity 92 percent). Sonographically, implant rupture is demonstrated by the "stepladder sign." Double-lumen implants may appear as false-positive results for rupture on sonography. On MRI, the "linguine sign" represents disrupted fragments of a ruptured implant. The most reliable imaging modality for implant rupture detection is MRI, followed by sonogram. Mammogram is the least reliable. Our study supports the clinical indication and diagnostic value of sonogram and MRI in the evaluation of symptomatic breast implant patients.

  17. Erbium implantation in Strontium Titanate

    CERN Document Server

    Araújo, J P; Alves, E; Correia, J G; Monteiro, T; Soares, J; Santos, L

    2002-01-01

    We report on the lattice location of Er in SrTiO$_{3}$ single crystals using the emission channeling technique. The angular distribution of conversion electrons emitted from $^{167m}$Er(T$_{1/2}$=2.27 s) was monitored with a position-sensitive detector following the room-temperature 60 keV implantation of the precursor isotope $^{167}$Tm(T$_{1/2}$=9.25 d) to a dose of 2$\\times$ 10$^{12}$ at./cm$^{2}$. The results for the sample annealed in vacuum at 610°C for 15 min provide direct evidence that Er occupies both Sr and Ti substitutional lattice sites. In addition, thermal recovery of lattice damage was also studied with RBS/C for SrTiO$_{3}$ implanted to doses of 5$\\times$ 10$^{14}$ and 5 $\\times$ 10$^{15}$ Er/cm$^{2}$. We further comment on preliminary photoluminescence results from these samples.

  18. Implantable Neural Interfaces for Sharks

    Science.gov (United States)

    2007-05-01

    technology for recording and stimulating from the auditory and olfactory sensory nervous systems of the awake, swimming nurse shark , G. cirratum (Figures...overlay of the central nervous system of the nurse shark on a horizontal MR image. Implantable Neural Interfaces for Sharks ...Neural Interfaces for Characterizing Population Responses to Odorants and Electrical Stimuli in the Nurse Shark , Ginglymostoma cirratum.” AChemS Abs

  19. Tooth Retained Implant: No More an Oxymoron

    Directory of Open Access Journals (Sweden)

    Divya Bhat

    2011-03-01

    Full Text Available Introduction: Periodontally af-fected teeth are treated in one of the two ways. (1 Tooth retention after periodontal surgery, in which the degree of regeneration achieved is unpredictable. (2 Tooth extrac-tion and implant placement. Implants have an osseointegrated surface which does not provide adequate shock absorption. Regeneration can be achieved by resecting the crown of the affected tooth and submerging the root. This technique has not had a clinical application so far as the tooth becomes difficult to restore. Placing an implant within the root can make the retained root restorable. At the same time, as the implant is placed within the root surface it achieves a periodontal integration which dampens occlusal forces better than osseointegration. Therefore, such a “tooth retained implant” may serve as an additional treatment option with significant benefits over tooth retention and implant placement alone. The hypothesis: Implants placed within retained roots have shown cementum deposition and attachment of periodontal ligament fibers over their surface. This periodontal attachment may be able to dam-pen forces better than in an osseointegrated implant. Moreover, since an implant is being placed, the crown of the tooth can be resected and submerged. This prevents epithelial migration, allows for the periodontal ligament cells to populate the wound and favors regeneration.Evaluation of the hypothesis: The technique of placing implants within cavities prepared in the root and then submerging them are simple for any practitioner placing implants routinely.

  20. R&D on dental implants breakage

    Science.gov (United States)

    Croitoru, Sorin Mihai; Popovici, Ion Alexandru

    2017-09-01

    Most used dental implants for human dental prostheses are of two steps type: first step means implantation and, after several months healing and osseointegration, second step is prosthesis fixture. For sure, dental implants and prostheses are meant to last for a lifetime. Still, there are unfortunate cases when dental implants break. This paper studies two steps dental implants breakage and proposes a set of instruments for replacement and restoration of the broken implant. First part of the paper sets the input data of the study: structure of the studied two steps dental implants based on two Romanian patents and values of the loading forces found in practice and specialty papers. In the second part of the paper, using DEFORM 2D™ FEM simulation software, worst case scenarios of loading dental implants are studied in order to determine which zones and components of the dental implant set are affected (broken). Last part of the paper is dedicated to design and presentation of a set for extracting and cutting tools used to restore the broken implant set.

  1. Management of peri-implant infections

    Directory of Open Access Journals (Sweden)

    K L Vandana

    2015-01-01

    Full Text Available The ever-increasing popularity of dental implants in recent years has been associated with the reported incidence of short-term and long-term complications such as peri-implant mucositis and peri-implantitis. Therapies proposed for treating peri-implantitis are based on the evidence available for the treatment of periodontitis, and are aimed at reducing the bacterial load within peri-implant pockets and decontaminating implant surfaces, and, in some cases, attempting afterward to bring about bone regeneration. The treatment of peri-implant infections comprises conservative (nonsurgical and surgical approaches. This paper reviews various treatment strategies used for the treatment of peri-implant diseases. There are many approaches suggested by various authors for the treatment of peri-implant diseases, but there is no “ideal peri-implant therapy” that has been described in the literature. There is no consensus regarding the treatment protocol as the studies conducted so far have had varying study designs, small sample sizes, and short follow-up periods.

  2. Miniscrew implant applications in contemporary orthodontics

    Directory of Open Access Journals (Sweden)

    Hong-Po Chang

    2014-03-01

    Full Text Available The need for orthodontic treatment modalities that provide maximal anchorage control but with minimal patient compliance requirements has led to the development of implant-assisted orthodontics and dentofacial orthopedics. Skeletal anchorage with miniscrew implants has no patient compliance requirements and has been widely incorporated in orthodontic practice. Miniscrew implants are now routinely used as anchorage devices in orthodontic treatment. This review summarizes recent data regarding the interpretation of bone data (i.e., bone quantity and quality obtained by preoperative diagnostic computed tomography (CT or by cone-beam computed tomography (CBCT prior to miniscrew implant placement. Such data are essential when selecting appropriate sites for miniscrew implant placement. Bone characteristics that are indications and contraindications for treatment with miniscrew implants are discussed. Additionally, bicortical orthodontic skeletal anchorage, risks associated with miniscrew implant failure, and miniscrew implants for nonsurgical correction of occlusal cant or vertical excess are reviewed. Finally, implant stability is compared between titanium alloy and stainless steel miniscrew implants.

  3. Customizable cap implants for neurophysiological experimentation.

    Science.gov (United States)

    Blonde, Jackson D; Roussy, Megan; Luna, Rogelio; Mahmoudian, Borna; Gulli, Roberto A; Barker, Kevin C; Lau, Jonathan C; Martinez-Trujillo, Julio C

    2018-04-22

    Several primate neurophysiology laboratories have adopted acrylic-free, custom-fit cranial implants. These implants are often comprised of titanium or plastic polymers, such as polyether ether ketone (PEEK). Titanium is favored for its mechanical strength and osseointegrative properties whereas PEEK is notable for its lightweight, machinability, and MRI compatibility. Recent titanium/PEEK implants have proven to be effective in minimizing infection and implant failure, thereby prolonging experiments and optimizing the scientific contribution of a single primate. We created novel, customizable PEEK 'cap' implants that contour to the primate's skull. The implants were created using MRI and/or CT data, SolidWorks software and CNC-machining. Three rhesus macaques were implanted with a PEEK cap implant. Head fixation and chronic recordings were successfully performed. Improvements in design and surgical technique solved issues of granulation tissue formation and headpost screw breakage. Primate cranial implants have traditionally been fastened to the skull using acrylic and anchor screws. This technique is prone to skin recession, infection, and implant failure. More recent methods have used imaging data to create custom-fit titanium/PEEK implants with radially extending feet or vertical columns. Compared to our design, these implants are more surgically invasive over time, have less force distribution, and/or do not optimize the utilizable surface area of the skull. Our PEEK cap implants served as an effective and affordable means to perform electrophysiological experimentation while reducing surgical invasiveness, providing increased strength, and optimizing useful surface area. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  4. Implantation rate effects on microstructure

    International Nuclear Information System (INIS)

    Choyke, W.J.; Spitznagel, J.A.; Wood, S.; Doyle, N.J.

    1981-01-01

    We report a detailed TEM study of rate effects in a metal (304 SS) where we dope with an insoluble atom (He) and create the displacement damage with high energy Si. The rates of doping and the rates of producing lattice damage are independently varied during dual implantation. In addition to varying the doping rates of the He the magnitude of the displacement damage prior to He implantation is also varied (beam history). We find that the beam history has virtually no effect on maximum bubble size but it has a major effect on the average cavity diameter. A weak dependence of cavity number density on helium implantation rate is found. The total dislocation density is relatively independent of the doping rate and beam history at 550 and 700 0 C, whereas the loop fraction is sensitive to beam history at these temperatures. Acicular precipitate formation is weakly dependent on doping, doping rate and more strongly dependent on doping concentration and temperature. This form of solute segregation is very sensitive to beam history. (orig.)

  5. Survival of dental implants placed in sites of previously failed implants.

    Science.gov (United States)

    Chrcanovic, Bruno R; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    2017-11-01

    To assess the survival of dental implants placed in sites of previously failed implants and to explore the possible factors that might affect the outcome of this reimplantation procedure. Patients that had failed dental implants, which were replaced with the same implant type at the same site, were included. Descriptive statistics were used to describe the patients and implants; survival analysis was also performed. The effect of systemic, environmental, and local factors on the survival of the reoperated implants was evaluated. 175 of 10,096 implants in 98 patients were replaced by another implant at the same location (159, 14, and 2 implants at second, third, and fourth surgeries, respectively). Newly replaced implants were generally of similar diameter but of shorter length compared to the previously placed fixtures. A statistically significant greater percentage of lost implants were placed in sites with low bone quantity. There was a statistically significant difference (P = 0.032) in the survival rates between implants that were inserted for the first time (94%) and implants that replaced the ones lost (73%). There was a statistically higher failure rate of the reoperated implants for patients taking antidepressants and antithrombotic agents. Dental implants replacing failed implants had lower survival rates than the rates reported for the previous attempts of implant placement. It is suggested that a site-specific negative effect may possibly be associated with this phenomenon, as well as the intake of antidepressants and antithrombotic agents. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Influence of different implant materials on the primary stability of orthodontic mini-implants.

    Science.gov (United States)

    Pan, Chin-Yun; Chou, Szu-Ting; Tseng, Yu-Chuan; Yang, Yi-Hsin; Wu, Chao-Yi; Lan, Ting-Hsun; Liu, Pao-Hsin; Chang, Hong-Po

    2012-12-01

    This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm). The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm) and stainless steel mini-implants 10 mm in length. The mini-implants were inserted into artificial bones with a 2-mm-thick cortical layer and 40 or 20 lb/ft(3) trabecular bone density at insertion depths of 2, 4, and 6 mm. The resonance frequency of the mini-implants in the artificial bone was detected with the Implomates(®) device. Data were analyzed by two-way analysis of variance followed by the Tukey honestly significant difference test (α = 0.05). Greater insertion depth resulted in higher resonance frequency, whereas longer mini-implants showed lower resonance frequency values. However, resonance frequency was not influenced by the implant materials titanium alloy or stainless steel. Therefore, the primary stability of a mini-implant is influenced by insertion depth and not by implant material. Insertion depth is extremely important for primary implant stability and is critical for treatment success. Copyright © 2012. Published by Elsevier B.V.

  7. Influence of different implant materials on the primary stability of orthodontic mini-implants

    Directory of Open Access Journals (Sweden)

    Chin-Yun Pan

    2012-12-01

    Full Text Available This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm. The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm and stainless steel mini-implants 10 mm in length. The mini-implants were inserted into artificial bones with a 2-mm-thick cortical layer and 40 or 20 lb/ft3 trabecular bone density at insertion depths of 2, 4, and 6 mm. The resonance frequency of the mini-implants in the artificial bone was detected with the Implomates® device. Data were analyzed by two-way analysis of variance followed by the Tukey honestly significant difference test (α = 0.05. Greater insertion depth resulted in higher resonance frequency, whereas longer mini-implants showed lower resonance frequency values. However, resonance frequency was not influenced by the implant materials titanium alloy or stainless steel. Therefore, the primary stability of a mini-implant is influenced by insertion depth and not by implant material. Insertion depth is extremely important for primary implant stability and is critical for treatment success.

  8. Methods to measure stability of dental implants

    Directory of Open Access Journals (Sweden)

    Shruti Digholkar

    2014-01-01

    Full Text Available Dental implant treatment is an excellent option for prosthetic restoration that is associated with high success rates. Implant stability is essential for a good outcome. The clinical assessment of osseointegration is based on mechanical stability rather than histological criteria, considering primary stability (absence of mobility in bone bed after implant insertion and secondary stability (bone formation and remodeling at implant-bone interface. However, due to the invasive nature of the histological methods various other methods have been proposed: Radiographs, the surgeon′s perception, Insertion torque (cutting torque analysis, seating torque, reverse torque testing, percussion testing, impact hammer method, pulsed oscillation waveform, implant mobility checker, Periotest, resonance frequency analysis. This review focuses on the methods currently available for the evaluation of implant stability.

  9. Electrochemical properties of ion implanted silicon

    International Nuclear Information System (INIS)

    Pham minh Tan.

    1979-11-01

    The electrochemical behaviour of ion implanted silicon in contact with hydrofluoric acid solution was investigated. It was shown that the implanted layer on silicon changes profoundly its electrochemical properties (photopotential, interface impedance, rest potential, corrosion, current-potential behaviour, anodic dissolution of silicon, redox reaction). These changes depend strongly on the implantation parameters such as ion dose, ion energy, thermal treatment and ion mass and are weakly dependent on the chemical nature of the implantation ion. The experimental results were evaluated and interpreted in terms of the semiconductor electrochemical concepts taking into account the interaction of energetic ions with the solid surface. The observed effects are thus attributed to the implantation induced damage of silicon lattice and can be used for profiling of the implanted layer and the electrochemical treatment of the silicon surface. (author)

  10. Early Loaded Single Implant Reinforced Mandibular Overdenture

    Directory of Open Access Journals (Sweden)

    K. Nischal

    2016-01-01

    Full Text Available Rehabilitating atrophied mandible with two-implant supported denture is a common treatment modality for implant retained removable overdenture in mandible. This paper aims to design a treatment modality where single implant reinforced overdenture is fabricated for a severely atrophied mandibular ridge with early loading protocol. Results of studies have shown that a single implant mandibular overdenture significantly increases the satisfaction and quality of life of patients with edentulism. Midline fracture of the prosthesis is the most common complication related to single implant and two-implant retained mandibular overdentures. To manage such complication, a thin metal mesh is used to reinforce the overdenture and also to make the prostheses lighter and cost effective as compared to conventional cast metal framework.

  11. Implant supported overdentures--the Copenhagen experience

    DEFF Research Database (Denmark)

    Gotfredsen, K

    1997-01-01

    OBJECTIVES: To evaluate the functional and biological effect of implant-supported overdenture treatment in the lower jaw. METHODS AND MATERIALS: Thirty-two patients were consecutively treated with Astra Tech implants in the lower jaw for retaining overdentures. All implants had a diameter of 3.5 mm...... and all but two of the implants were longer than 10 mm. For the implant supported overdentures two methods of attachment were used, a bar or a ball. RESULTS: One of 69 fixtures was lost during the 4-5 year observation period. The mean bone loss for all fixtures was less than 0.2 mm per year. Complications...... quality and quantity is sufficient, two implants can support an overdenture in the lower jaw, providing prosthesis which functions well....

  12. [Fusion implants of carbon fiber reinforced plastic].

    Science.gov (United States)

    Früh, H J; Liebetrau, A; Bertagnoli, R

    2002-05-01

    Carbon fiber reinforced plastics (CFRP) are used in the medical field when high mechanical strength, innovative design, and radiolucency (see spinal fusion implants) are needed. During the manufacturing process of the material CFRP carbon fibers are embedded into a resin matrix. This resin material could be thermoset (e.g., epoxy resin EPN/DDS) or thermoplastic (e.g., PEAK). CFRP is biocompatible, radiolucent, and has higher mechanical capabilities compared to other implant materials. This publication demonstrates the manufacturing process of fusion implants made of a thermoset matrix system using a fiber winding process. The material has been used clinically since 1994 for fusion implants of the cervical and lumbar spine. The results of the fusion systems CORNERSTONE-SR C (cervical) and UNION (lumbar) showed no implant-related complications. New implant systems made of this CFRP material are under investigation and are presented.

  13. A case of peri-implantitis and osteoradionecrosis arising around dental implants placed before radiation therapy

    OpenAIRE

    Teramoto, Yuji; Kurita, Hiroshi; Kamata, Takahiro; Aizawa, Hitoshi; Yoshimura, Nobuhiko; Nishimaki, Humihiro; Takamizawa, Kazunobu

    2016-01-01

    A little is known about the effect of radiotherapy on the dental implants that have previously been osseointegrated and charged. Here, we reported a case of osteoradionecrosis which arose around dental implants placed before radiation therapy.

  14. Long time follow up of implant therapy and treatment of peri-implantitis.

    Science.gov (United States)

    Roos-Jansåker, Ann-Marie

    2007-01-01

    Dental implants have become an often used alternative to replace missing teeth, resulting in an increasing percentage of the adult population with implant supported prosthesis. Although favourable long-term results of implant therapy have been reported, infections occur. Until recently few reports included data on peri-implant infections, possibly underestimating this complication of implant treatment. It is possible that some infections around implants develop slowly and that with time peri-implantitis will be a common complication to implant therapy as an increasing number of patients have had their implants for a long time (>10 years). Data on treatment of peri-implant lesions are scarce leaving the clinician with limited guidance regarding choice of treatment. The aim of this thesis was to study the frequency of implant loss and presence of peri-implant lesions in a group of patients supplied with Brånemark implants 9-14 years ago, and to relate these events to patient and site specific characteristics. Moreover three surgical treatment modalities for peri-implantitis were evaluated. The thesis is based on six studies; Studies I-III included 218 patients and 1057 implants followed for 9-14 years evaluating prevalence of, and factors related to implant loss (Paper I) and prevalence of peri-implant infections and related factors (Paper I-III). Study IV is a review describing different treatment modalities of peri-implant infections. Study V is a prospective cohort study involving 36 patients and 65 implants, evaluating the use of a bone substitute with or without the use of a resorbable membrane. Study VI is a case series with 12 patients and 16 implants, evaluating a bone substitute in combination with a resorbable membrane and submerged healing. This thesis demonstrated that: After 9-14 years the survival rates of dental implants are high (95.7%). Implant loss seems to cluster within patients and are related to periodontitis evidenced as bone loss on

  15. Infective endocarditis and risk of death after cardiac implantable electronic device implantation

    DEFF Research Database (Denmark)

    Özcan, Cengiz; Raunsø, Jakob; Lamberts, Morten

    2017-01-01

    AIMS: To determine the incidence, risk factors, and mortality of infective endocarditis (IE) following implantation of a first-time, permanent, cardiac implantable electronic device (CIED). METHODS AND RESULTS: From Danish nationwide administrative registers (beginning in 1996), we identified all...

  16. Strain driven fast osseointegration of implants

    Directory of Open Access Journals (Sweden)

    Wiesmann Hans-Peter

    2005-09-01

    Full Text Available Abstract Background Although the bone's capability of dental implant osseointegration has clinically been utilised as early as in the Gallo-Roman population, the specific mechanisms for the emergence and maintenance of peri-implant bone under functional load have not been identified. Here we show that under immediate loading of specially designed dental implants with masticatory loads, osseointegration is rapidly achieved. Methods We examined the bone reaction around non- and immediately loaded dental implants inserted in the mandible of mature minipigs during the presently assumed time for osseointegration. We used threaded conical titanium implants containing a titanium2+ oxide surface, allowing direct bone contact after insertion. The external geometry was designed according to finite element analysis: the calculation showed that physiological amplitudes of strain (500–3,000 ustrain generated through mastication were homogenously distributed in peri-implant bone. The strain-energy density (SED rate under assessment of a 1 Hz loading cycle was 150 Jm-3 s-1, peak dislocations were lower then nm. Results Bone was in direct contact to the implant surface (bone/implant contact rate 90% from day one of implant insertion, as quantified by undecalcified histological sections. This effect was substantiated by ultrastructural analysis of intimate osteoblast attachment and mature collagen mineralisation at the titanium surface. We detected no loss in the intimate bone/implant bond during the experimental period of either control or experimental animals, indicating that immediate load had no adverse effect on bone structure in peri-implant bone. Conclusion In terms of clinical relevance, the load related bone reaction at the implant interface may in combination with substrate effects be responsible for an immediate osseointegration state.

  17. Characterization of diamond amorphized by ion implantation

    International Nuclear Information System (INIS)

    Allen, W.R.; Lee, E.H.

    1992-01-01

    Single crystal diamond has been implanted at 1 MeV with 2 x 10 20 Ar/m 2 . Rutherford backscattering spectrometry in a channeled geometry revealed a broad amorphized region underlying a thin, partially crystalline layer. Raman spectroscopy disclosed modifications in the bonding characteristic of the appearance of non-diamond carbon. The complementary nature of the two analysis techniques is demonstrated. The Knoop hardness of the implanted diamond was reduced by implantation

  18. Modification of metallic corrosion by ion implantation

    International Nuclear Information System (INIS)

    Clayton, C.R.

    1981-01-01

    This review will consider some of the properties of surface alloys, formed by ion implantation, which are effective in modifying corrosion behaviour. Examples will be given of the modification of the corrosion behaviour of pure metals, steels and other engineering alloys, resulting from implantation with metals and metalloids. Emphasis will be given to the modification of anodic processes produced by ion implantation since a review will be given elsewhere in the proceedings concerning the modification of cathodic processes. (orig.)

  19. Relation between bruxism and dental implants

    OpenAIRE

    TORCATO,Leonardo Bueno; ZUIM,Paulo Renato Junqueira; BRANDINI,Daniela Atili; FALCÓN-ANTENUCCI,Rosse Mary

    2014-01-01

    OBJECTIVE: The aim of this study was to gather information and discuss the predictability of implant-supported prostheses in patients with bruxism by performing a literature review.METHODS: In order to select the studies included in this review, a detailed search was performed in PubMed and Medlinedatabases, using the following key words: bruxism, dental implants, implant supported prosthesis, and dental restoration failure. Items that were included are: case reports, randomized controlled tr...

  20. CEMS of Sb+ implanted stainless steels

    International Nuclear Information System (INIS)

    Roy-Poulsen, H.; Johnson, E.; Johansen, A.; Sarholt-Kristensen, L.; Hayashi, H.

    1986-01-01

    Martensitic transformations have been analyzed in a series of antimony implanted austenitic stainless steels using CEMS. The implanted samples contain about 70 vol% martensite, which is considerably more than can be formed conventionally by plastic deformation of cooling below the martensite start temperature. CEM spectra from implantation induced martensite and from martensite formed in conventional processes are virtually identical. In both cases the hyperfine field is ∼ 25T. (Auth.)

  1. CEMS of Sb+ implanted stainless steels

    International Nuclear Information System (INIS)

    Roy-Poulsen, H.; Copenhagen Univ.; Johnson, E.; Johansen, A.; Sarholt-Kristensen, L.; Hayashi, H.

    1985-01-01

    Martensitic transformations have been analyzed in a series of antimony implanted austenitic stainless steels using CEMS. The implanted samples contain about 70 vol% martensite, which is considerably more than can be formed conventionally by plastic deformation or cooling below the martensite start temperature. CEM spectra from implantation induced martensite and from martensite formed in conventional processes are virtually identical. In both cases the hyperfine field is ∝25 T. (orig.)

  2. Cochlear implant revision surgeries in children.

    Science.gov (United States)

    Amaral, Maria Stella Arantes do; Reis, Ana Cláudia Mirândola B; Massuda, Eduardo T; Hyppolito, Miguel Angelo

    2018-02-16

    The surgery during which the cochlear implant internal device is implanted is not entirely free of risks and may produce problems that will require revision surgeries. To verify the indications for cochlear implantation revision surgery for the cochlear implant internal device, its effectiveness and its correlation with certain variables related to language and hearing. A retrospective study of patients under 18 years submitted to cochlear implant Surgery from 2004 to 2015 in a public hospital in Brazil. Data collected were: age at the time of implantation, gender, etiology of the hearing loss, audiological and oral language characteristics of each patient before and after Cochlear Implant surgery and any need for surgical revision and the reason for it. Two hundred and sixty-five surgeries were performed in 236 patients. Eight patients received a bilateral cochlear implant and 10 patients required revision surgery. Thirty-two surgeries were necessary for these 10 children (1 bilateral cochlear implant), of which 21 were revision surgeries. In 2 children, cochlear implant removal was necessary, without reimplantation, one with cochlear malformation due to incomplete partition type I and another due to trauma. With respect to the cause for revision surgery, of the 8 children who were successfully reimplanted, four had cochlear calcification following meningitis, one followed trauma, one exhibited a facial nerve malformation, one experienced a failure of the cochlear implant internal device and one revision surgery was necessary because the electrode was twisted. The incidence of the cochlear implant revision surgery was 4.23%. The period following the revision surgeries revealed an improvement in the subject's hearing and language performance, indicating that these surgeries are valid in most cases. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  3. One-stage explant-implant procedure of exposed porous orbital implants

    DEFF Research Database (Denmark)

    Toft, Peter B; Rasmussen, Marie L Roed; Prause, Jan Ulrik

    2011-01-01

    Purpose:  To investigate the risks of implant exposure after a combined explant-implant procedure in patients with an exposed porous orbital implant. Methods:  Twenty-four consecutive patients who had a combined explant-implant procedure of an exposed hydroxyapatite (21) or porous polyethylene (3...... at the same procedure in sockets without profound signs of infection. The procedure carries a possible risk of poor motility....

  4. Systemic alendronate treatment improves fixation of press-fit implants: a canine study using nonloaded implants

    DEFF Research Database (Denmark)

    Jensen, Thomas B; Bechtold, Joan E; Chen, Xinqian

    2007-01-01

    of alendronate treatment. Bone ongrowth (bone in contact with implant surface) was estimated using the linear intercept technique and shear strength was calculated as the slope on a load-displacement curve. For the press fit implants, alendronate treatment significantly increased bone ongrowth from 24% to 29...... early implant stability is an important predictor of longevity, systemic alendronate treatment could be an important clinical tool to positively influence the early stages of implant incorporation. Udgivelsesdato: 2007-Jun...

  5. Neural Implants, Packaging for Biocompatible Implants, and Improving Fabricated Capacitors

    Science.gov (United States)

    Agger, Elizabeth Rose

    We have completed the circuit design and packaging procedure for an NIH-funded neural implant, called a MOTE (Microscale Optoelectronically Transduced Electrode). Neural recording implants for mice have greatly advanced neuroscience, but they are often damaging and limited in their recording location. This project will result in free-floating implants that cause less damage, provide rapid electronic recording, and increase range of recording across the cortex. A low-power silicon IC containing amplification and digitization sub-circuits is powered by a dual-function gallium arsenide photovoltaic and LED. Through thin film deposition, photolithography, and chemical and physical etching, the Molnar Group and the McEuen Group (Applied and Engineering Physics department) will package the IC and LED into a biocompatible implant approximately 100microm3. The IC and LED are complete and we have begun refining this packaging procedure in the Cornell NanoScale Science & Technology Facility. ICs with 3D time-resolved imaging capabilities can image microorganisms and other biological samples given proper packaging. A portable, flat, easily manufactured package would enable scientists to place biological samples on slides directly above the Molnar group's imaging chip. We have developed a packaging procedure using laser cutting, photolithography, epoxies, and metal deposition. Using a flip-chip method, we verified the process by aligning and adhering a sample chip to a holder wafer. In the CNF, we have worked on a long-term metal-insulator-metal (MIM) capacitor characterization project. Former Fellow and continuing CNF user Kwame Amponsah developed the original procedure for the capacitor fabrication, and another former fellow, Jonilyn Longenecker, revised the procedure and began the arduous process of characterization. MIM caps are useful to clean room users as testing devices to verify electronic characteristics of their active circuitry. This project's objective is to

  6. Trends in prosthetic biomaterials in implant dentistry

    Directory of Open Access Journals (Sweden)

    Saranjit Singh Bhasin

    2015-01-01

    Full Text Available The most important criterion for the success of dental implants is the selection of a suitable implant biomaterial. To improve the biologic performance of an implant, it is necessary to select a material that does not elicit any negative biological response and at the same time maintains adequate function. It is mandatory for a dentist to have a comprehensive knowledge of various biomaterials used for dental implants. The material of choice for fabrication of the dental implant till date is titanium. With the advancements in the field of implants, zirconia seems to be propitious in the future. However, more advanced in vitro and in vivo studies are required before reaching any such conclusion. To increase the success of zirconia implants, care should be taken to reduce the incidence of mechanical failures. Such failures can be taken care of by having a thorough technical knowledge of implant designing and manufacturing defects. This article attempts to compare the advantages and disadvantages of various dental implant biomaterials. Focus is placed on the recent advances in this field with the recently introduced zirconia and its comparison to conventional titanium.

  7. He implantation induced nanovoids in crystalline Si

    International Nuclear Information System (INIS)

    Kilpelaeinen, S.; Kuitunen, K.; Slotte, J.; Tuomisto, F.; Bruno, E.; Mirabella, S.; Priolo, F.

    2009-01-01

    Positron annihilation spectroscopy (PAS) in Doppler broadening mode was used to study the vacancy profile of crystalline Si after He and B implantation and subsequent annealing. In the He-implanted samples two different void layers were observed, one consisting of large voids at the projected range of He and another containing 'nanovoids' slightly larger than divacancies at roughly halfway between R p of He and the surface. The nanovoid layer was shown to be absent from samples co-implanted with B, implying that interstitials created during B implantation get trapped in the nanovoids and fill them, thus hindering interstitial-mediated B diffusion.

  8. Ion implantation of boron in germanium

    International Nuclear Information System (INIS)

    Jones, K.S.

    1985-05-01

    Ion implantation of 11 B + into room temperature Ge samples leads to a p-type layer prior to any post implant annealing steps. Variable temperature Hall measurements and deep level transient spectroscopy experiments indicate that room temperature implantation of 11 B + into Ge results in 100% of the boron ions being electrically active as shallow acceptor, over the entire dose range (5 x 10 11 /cm 2 to 1 x 10 14 /cm 2 ) and energy range (25 keV to 100 keV) investigated, without any post implant annealing. The concentration of damage related acceptor centers is only 10% of the boron related, shallow acceptor center concentration for low energy implants (25 keV), but becomes dominant at high energies (100 keV) and low doses ( 12 /cm 2 ). Three damage related hole traps are produced by ion implantation of 11 B + . Two of these hole traps have also been observed in γ-irradiated Ge and may be oxygen-vacancy related defects, while the third trap may be divacancy related. All three traps anneal out at low temperatures ( 0 C). Boron, from room temperature implantation of BF 2 + into Ge, is not substitutionally active prior to a post implant annealing step of 250 0 C for 30 minutes. After annealing additional shallow acceptors are observed in BF 2 + implanted samples which may be due to fluorine or flourine related complexes which are electrically active

  9. Endothelial cell adhesion to ion implanted polymers

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Y; Kusakabe, M [SONY Corp., Tokyo (Japan); Lee, J S; Kaibara, M; Iwaki, M; Sasabe, H [RIKEN (Inst. of Physical and Chemical Research), Saitama (Japan)

    1992-03-01

    The biocompatibility of ion implanted polymers has been studied by means of adhesion measurements of bovine aorta endothelial cells in vitro. The specimens used were polystyrene (PS) and segmented polyurethane (SPU). Na{sup +}, N{sub 2}{sup +}, O{sub 2}{sup +} and Kr{sup +} ion implantations were performed at an energy of 150 keV with fluences ranging from 1x10{sup 15} to 3x10{sup 17} ions/cm{sup 2} at room temperature. The chemical and physical structures of ion-implanted polymers have been investigated in order to analyze their tissue compatibility such as improvement of endothelial cell adhesion. The ion implanted SPU have been found to exhibit remarkably higher adhesion and spreading of endothelial cells than unimplanted specimens. By contrast, ion implanted PS demonstrated a little improvement of adhesion of cells in this assay. Results of FT-IR-ATR showed that ion implantation broke the original chemical bond to form new radicals such as OH, ....C=O, SiH and condensed rings. The results of Raman spectroscopy showed that ion implantation always produced a peak near 1500 cm{sup -1}, which indicated that these ion implanted PS and SPU had the same carbon structure. This structure is considered to bring the dramatic increase in the extent of cell adhesion and spreading to these ion implanted PS and SPU. (orig.).

  10. Prevention and management of cochlear implant infections.

    Science.gov (United States)

    Gluth, Michael B; Singh, Rajesh; Atlas, Marcus D

    2011-11-01

    Understanding the issues of infection related to an implantable medical device is crucial to all cochlear implant teams. Furthermore, given the risk of central nervous system complications and the relatively high quantity of underlying resource investment associated with cochlear implantation, the stakes of infection are high. The optimal strategies to prevent and manage such infections are still evolving as good-quality prospective data to guide such management decisions are not yet abundant within the medical literature and many recommendations are based on retrospective reviews or anecdotal evidence. We will outline a general strategy to deal with cochlear implant-related infection based on both the authors' experience and the published literature.

  11. Digital photoelastic analysis applied to implant dentistry

    Science.gov (United States)

    Ramesh, K.; Hariprasad, M. P.; Bhuvanewari, S.

    2016-12-01

    Development of improved designs of implant systems in dentistry have necessitated the study of stress fields in the implant regions of the mandible/maxilla for better understanding of the biomechanics involved. Photoelasticity has been used for various studies related to dental implants in view of whole field visualization of maximum shear stress in the form of isochromatic contours. The potential of digital photoelasticity has not been fully exploited in the field of implant dentistry. In this paper, the fringe field in the vicinity of the connected implants (All-On-Four® concept) is analyzed using recent advances in digital photoelasticity. Initially, a novel 3-D photoelastic model making procedure, to closely mimic all the anatomical features of the human mandible is proposed. By choosing appropriate orientation of the model with respect to the light path, the essential region of interest were sought to be analysed while keeping the model under live loading conditions. Need for a sophisticated software module to carefully identify the model domain has been brought out. For data extraction, five-step method is used and isochromatics are evaluated by twelve fringe photoelasticity. In addition to the isochromatic fringe field, whole field isoclinic data is also obtained for the first time in implant dentistry, which could throw important information in improving the structural stability of the implant systems. Analysis is carried out for the implant in the molar as well as the incisor region. In addition, the interaction effects of loaded molar implant on the incisor area are also studied.

  12. High energy ion implantation for IC processing

    International Nuclear Information System (INIS)

    Oosterhoff, S.

    1986-01-01

    In this thesis the results of fundamental research on high energy ion implantation in silicon are presented and discussed. The implantations have been carried out with the 500 kV HVEE ion implantation machine, that was acquired in 1981 by the IC technology and Electronics group at Twente University of Technology. The damage and anneal behaviour of 1 MeV boron implantations to a dose of 10 13 /cm 2 have been investigated as a function of anneal temperature by sheet resistance, Hall and noise measurements. (Auth.)

  13. High energy P implants in silicon

    International Nuclear Information System (INIS)

    Raineri, V.; Cacciato, A.; Benyaich, F.; Priolo, F.; Rimini, E.; Galvagno, G.; Capizzi, S.

    1992-01-01

    Phosphorus ions in the energy range 0.25-1 MeV and in the dose range 2x10 13 -1x10 15 P/cm 2 were implanted into (100) Si single crystal at different tilt angles. In particular channeling and random conditions were investigated. For comparison some implants were performed on samples with a 2 μm thick surface amorphous layer. Chemical concentration P profiles were obtained by secondary ion mass spectrometry. Carrier concentration and mobility profile measurements were carried out by sheet resistance and Hall measurements on implanted van der Pauw patterns. Carrier concentration profiles were also obtained by spreading resistance (SR) measurements. The damage in the as-implanted samples was determined by backscattering and channeling spectrometry (RBS) as a function of the dose and implantation energy. Comparison of random implants in crystal with implants in amorphous layers shows that in the first case it is impossible to completely avoid the channeling tail. In the implants performed under channeling conditions at low doses the P profiles are flat over more than 2 μm thick layers. Furthermore, by increasing the implanted dose, the shape of the profiles dramatically changes due to the dechanneling caused by the crystal disorder. The data are discussed and compared with Monte Carlo simulations using the MARLOWE code. A simple description of the electronic energy loss provides an excellent agreement between the calculated and experimental profiles. (orig.)

  14. Helium implantation effects in SAP and aluminum

    International Nuclear Information System (INIS)

    Bauer, W.; Thomas, G.J.

    1976-02-01

    A series of 300 keV He implantations of Al and SAP 930 have been conducted at temperatures between 150 and 773K. The He re-emission was monitored during implantation and the samples were examined with a scanning electron microscope after implantation. Both Al and SAP 930 were found to blister after a critical He dose was reached at temperatures above 473K, both underwent flaking below that temperature, with blistering re-appearing in SAP 930 at an implantation temperature of 150K. The surface deformation and He re-emission are strongly dependent on microstructural effects in the intermediate temperature regime

  15. Determining factors for implant referral rates.

    Science.gov (United States)

    Levin, Roger P

    2002-01-01

    The research findings indicate that the field of implant dentistry will only grow at a moderately low level unless certain changes are made. Findings indicated that the effort by the implant companies has been nothing short of dramatic, and yet almost 60% of restorative doctors do not participate annually in any implant case. There was no clear indication that younger restorative doctors will significantly increase the number of implant referrals, as their overall implant education has not dramatically differed from those dentists who graduated in earlier years. Once the research was completed, it became obvious to Levin Group that the driving force behind implant referral growth will be implant surgeons, because of their one-to-one relationship with restorative doctors. The Levin Group Implant Management and Marketing Consulting Program is based on approaching restorative doctors in several different levels, starting with awareness all the way through to case facilitation and long-term tracking and communication. Finally, a continuing marketing/education effort needs to be consistently in place with effective materials, not only to create a high level of awareness, but also to motivate restorative doctors to refer cases and then work through the case with the implant surgeon to a satisfactory completion for the restorative doctor, implant surgeon, and patient. While the surgical insertion of implants may seem to carry a high-profit margin relative to the restoration of implants, the truth is that the restoration of implants usually provides a 40% higher profit margin for the restorative doctor than traditional dental services. One of the key issues is that referring doctors have not necessarily learned how to set fees and present cases with regard to implant dentistry. The key factor here is to ensure that the patient understands that implant services involve higher fees than traditional services, because of the necessarily higher levels of experience, education

  16. Treatment planning of implants in posterior quadrants.

    Science.gov (United States)

    Jivraj, S; Chee, W

    2006-07-08

    Differences in anatomy and biomechanics make treatment of posterior quadrants with dental implants substantially different to that of anterior areas. Without implants, when posterior teeth were lost, treatment options included a long span fixed partial denture or a removable prosthesis, especially when no terminal abutment was available. Today, with the use of implants, options are available that allow preservation of unrestored teeth.(1) When teeth are missing, implant supported restorations can be considered the treatment of choice from the perspective of occlusal support, preservation of adjacent teeth and avoidance of a removable partial denture.

  17. Mandibular implant-supported overdentures: Prosthetic overview

    Directory of Open Access Journals (Sweden)

    Fahad A Al-Harbi

    2018-01-01

    Full Text Available Implant-supported overdentures are becoming the treatment of choice for the completely edentulous mandible. They significantly improve the quality of life in edentulous patients. For this review article, the literature was searched to identify pertinent studies. No meta-analysis was conducted because of high heterogeneity within the literature. Accordingly, in this review article, the author provides an update on implant-supported mandible overdentures with regard to the number of implants, type of loading, stress–strain distribution, mode of implant-to-denture attachment, occlusal considerations and complications.

  18. Implant decontamination with phosphoric acid during surgical peri-implantitis treatment : a RCT

    NARCIS (Netherlands)

    Hentenaar, Diederik F M; De Waal, Yvonne C M; Strooker, Hans; Meijer, Henny J A; Van Winkelhoff, Arie-Jan; Raghoebar, Gerry M

    2017-01-01

    BACKGROUND: Peri-implantitis is known as an infectious disease that affects the peri-implant soft and hard tissue. Today, scientific literature provides very little evidence for an effective intervention protocol for treatment of peri-implantitis. The aim of the present randomized controlled trial

  19. A 5-year randomized trial to compare 1 or 2 implants for implant overdentures.

    Science.gov (United States)

    Bryant, S R; Walton, J N; MacEntee, M I

    2015-01-01

    The hypothesis of this 5-y randomized clinical trial was that there would be no significant difference in the satisfaction of edentulous participants with removable complete overdentures attached to 1 or 2 mandibular implants. Secondary aims were to test changes in satisfaction between and within the groups from baseline to 5 y and differences between the groups in implant survival and prosthodontic maintenance over 5 y. Each of the 86 participants (mean age, 67 y) was randomly allocated to receive either 1 implant in the midline (group 1) or 2 implants in the canine areas (group 2) attached to a mandibular overdenture opposing a maxillary complete denture. Satisfaction was self-assessed by participants on a visual analog scale at baseline prior to implants, as well as at 2 mo and 1, 3, and 5 y with implant overdentures, whereas implant survival and prosthodontic maintenance were assessed by clinical examination. After 5 y, 29 participants in group 1 and 33 in group 2 were available, with most dropouts due to death. Satisfaction with the implant denture after 5 y was significantly (P overdentures retained by 1 implant or 2 implants. Additional research is required to confirm long-term treatment effectiveness of single-implant dentures and the implications of prosthetic maintenance with implant overdentures (ClinicalTrials.gov: NCT02117856). © International & American Associations for Dental Research 2014.

  20. Azygos Vein Lead Implantation For High Defibrillation Thresholds In Implantable Cardioverter Defibrillator Placement

    Directory of Open Access Journals (Sweden)

    Naga VA Kommuri

    2010-01-01

    Full Text Available Evaluation of defibrillation threshold is a standard of care during implantation of implantable cardioverter defibrillator. High defibrillation thresholds are often encountered and pose a challenge to electrophysiologists to improve the defibrillation threshold. We describe a case series where defibrillation thresholds were improved after implanting a defibrillation lead in the azygos vein.

  1. [Researches on biomechanics of micro-implant-bone interface and optimum design of micro implant's neck].

    Science.gov (United States)

    Deng, Feng; Zhang, Lei; Zhang, Yi; Song, Jin-lin; Fan, Yuboa

    2007-07-01

    To compare and analyze the stress distribution at the micro-implant-bone interface based on the different micro-implant-bone conditioned under orthodontic load, and to optimize the design of micro implant's neck. An adult skull with all tooth was scanned by spiral CT, and the data were imported into computer for three-dimensional reconstruction with software Mimics 9.0. The three dimensional finite element models of three micro-implant-bone interfaces(initial stability, full osseointegration and fibrous integration) were analyzed by finite element analysis software ABAQUS6.5. The primary stress distributions of different micro-implant-bone conditions were evaluated when 2N force was loaded. Then the diameter less than 1.5 mm of the micro implant's neck was added with 0.2 mm, to compare the stress distribution of the modified micro-implant-bone interface with traditional type. The stress mostly concentrated on the neck of micro implant and the full osseointegration interface in all models showed the lowest strain level. Compared with the traditional type, the increasing diameter neck of the micro implant obviously decreased the stress level in all the three conditions. The micro-implant-bone interface and the diameter of micro implant's neck both are the important influence factors to the stress distribution of micro implant.

  2. Primary prevention of peri-implantitis: managing peri-implant mucositis.

    Science.gov (United States)

    Jepsen, Søren; Berglundh, Tord; Genco, Robert; Aass, Anne Merete; Demirel, Korkud; Derks, Jan; Figuero, Elena; Giovannoli, Jean Louis; Goldstein, Moshe; Lambert, France; Ortiz-Vigon, Alberto; Polyzois, Ioannis; Salvi, Giovanni E; Schwarz, Frank; Serino, Giovanni; Tomasi, Cristiano; Zitzmann, Nicola U

    2015-04-01

    Over the past decades, the placement of dental implants has become a routine procedure in the oral rehabilitation of fully and partially edentulous patients. However, the number of patients/implants affected by peri-implant diseases is increasing. As there are--in contrast to periodontitis--at present no established and predictable concepts for the treatment of peri-implantitis, primary prevention is of key importance. The management of peri-implant mucositis is considered as a preventive measure for the onset of peri-implantitis. Therefore, the remit of this working group was to assess the prevalence of peri-implant diseases, as well as risks for peri-implant mucositis and to evaluate measures for the management of peri-implant mucositis. Discussions were informed by four systematic reviews on the current epidemiology of peri-implant diseases, on potential risks contributing to the development of peri-implant mucositis, and on the effect of patient and of professionally administered measures to manage peri-implant mucositis. This consensus report is based on the outcomes of these systematic reviews and on the expert opinion of the participants. Key findings included: (i) meta-analysis estimated a weighted mean prevalence for peri-implant mucositis of 43% (CI: 32-54%) and for peri-implantitis of 22% (CI: 14-30%); (ii) bleeding on probing is considered as key clinical measure to distinguish between peri-implant health and disease; (iii) lack of regular supportive therapy in patients with peri-implant mucositis was associated with increased risk for onset of peri-implantitis; (iv) whereas plaque accumulation has been established as aetiological factor, smoking was identified as modifiable patient-related and excess cement as local risk indicator for the development of peri-implant mucositis; (v) patient-administered mechanical plaque control (with manual or powered toothbrushes) has been shown to be an effective preventive measure; (vi) professional intervention

  3. The Biolink Implantable Telemetry System

    Science.gov (United States)

    Betancourt-Zamora, Rafael J.

    1999-01-01

    Most biotelemetry applications deal with the moderated data rates of biological signals. Few people have studied the problem of transcutaneous data transmission at the rates required by NASA's Life Sciences-Advanced BioTelemetry System (LS-ABTS). Implanted telemetry eliminate the problems associated with wire breaking the skin, and permits experiments with awake and unrestrained subjects. Our goal is to build a low-power 174-216MHz Radio Frequency (RF) transmitter suitable for short range biosensor and implantable use. The BioLink Implantable Telemetry System (BITS) is composed of three major units: an Analog Data Module (ADM), a Telemetry Transmitter Module (TTM), and a Command Receiver Module (CRM). BioLink incorporates novel low-power techniques to implement a monolithic digital RF transmitter operating at 100kbps, using quadrature phase shift keying (QPSK) modulation in the 174-216MHz ISM band. As the ADM will be specific for each application, we focused on solving the problems associated with a monolithic implementation of the TTM and CRM, and this is the emphasis of this report. A system architecture based on a Frequency-Locked Loop (FLL) Frequency Synthesizer is presented, and a novel differential frequency that eliminates the need for a frequency divider is also shown. A self sizing phase modulation scheme suitable for low power implementation was also developed. A full system-level simulation of the FLL was performed and loop filter parameters were determined. The implantable antenna has been designed, simulated and constructed. An implant package compatible with the ABTS requirements is also being proposed. Extensive work performed at 200MHz in 0.5um complementary metal oxide semiconductors (CMOS) showed the feasibility of integrating the RF transmitter circuits in a single chip. The Hajimiri phase noise model was used to optimize the Voltage Controlled Oscillator (VCO) for minimum power consumption. Two test chips were fabricated in a 0.5pm, 3V CMOS

  4. Osteogenesis and Morphology of the Peri-Implant Bone Facing Dental Implants

    Directory of Open Access Journals (Sweden)

    Marco Franchi

    2004-01-01

    Full Text Available This study investigated the influence of different implant surfaces on peri-implant osteogenesis and implant face morphology of peri-implant tissues during the early (2 weeks and complete healing period (3 months. Thirty endosseous titanium implants (conic screws with differently treated surfaces (smooth titanium = SS, titanium plasma sprayed = TPS, sand-blasted zirconium oxide = Zr-SLA were implanted in femur and tibiae diaphyses of two mongrel sheep. Histological sections of the implants and surrounding tissues obtained by sawing and grinding techniques were observed under light microscopy (LM. The peri-implant tissues of other samples were mechanically detached from the corresponding implants to be processed for SEM observation. Two weeks after implantation, we observed osteogenesis (new bone trabeculae around all implant surfaces only where a gap was present at the host bone-metal interface. No evident bone deposition was detectable where threads of the screws were in direct contact with the compact host bone. Distance osteogenesis predominated in SS implants, while around rough surfaces (TPS and Zr-SLA, both distance and contact osteogenesis were present. At SEM analysis 2 weeks after implantation, the implant face of SS peri-implant tissue showed few, thin, newly formed, bone trabeculae immersed in large, loose, marrow tissue with blood vessels. Around the TPS screws, the implant face of the peri-implant tissue was rather irregular because of the rougher metal surface. Zr-SLA screws showed more numerous, newly formed bone trabeculae crossing marrow spaces and also needle-like crystals in bone nodules indicating an active mineralising process. After 3 months, all the screws appeared osseointegrated, being almost completely covered by a compact, mature, newly formed bone. However, some marrow spaces rich in blood vessels and undifferentiated cells were in contact with the metal surface. By SEM analysis, the implant face of the peri-implant

  5. CT evaluation of preoperative cochlear implantation cochlear implantation

    International Nuclear Information System (INIS)

    Tan Xiuzhong; Zhong Lansheng; Lan Bowen; Huang Yaosheng; Du Baowen; Zhu Jian

    2004-01-01

    Objective: To evaluate CT scan as a preoperative evaluation for cochlear implantation candidates. Methods: Axial high-resolution temporal bone CT and three-dimensional reconstruction of inner ear were performed in 93 patients with sensorineural hearing loss. results: Among 81 patients with congenital sensorineural deafness, Mondini malformation was seen in 7 case (13 ears); large vestibular aqueduct syndrome (LVAS) was revealed in 5 cases (8 ears); and inner ear ossification was found in 1 case (2 ears). In 1 case (2 ears) of inner ear fibrosis, reduced cochlear signal was noted on MRI but no unremarkable findings was shown on CT scan, however, in the operation, the device could not inserted into the basal circle of the cochlea, due to fibrous obliteration. In 12 patients with post-speech deafness, chronic suppurative tympanitis was seen in 2 cases (4 ears), and inner ear ossification was revealed in 1 case (2 ears). Conclusion: CT plays an indispensable role in the pre-operative evaluation of cochlear implantation. T 2 -weighted FSE-MRI of the inner ear is a useful complementary to CT scan. (authors)

  6. Forming controlled inset regions by ion implantation and laser bombardment

    International Nuclear Information System (INIS)

    Gibbons, J.F.

    1981-01-01

    A semiconductor integrated circuit structure in which the inset regions are ion implanted and laser annealed to maintain substantially the dimensions of the implantation and the method of forming inset implanted regions having controlled dimensions

  7. Effects of elevated ambient temperature on embryo implantation in rats

    African Journals Online (AJOL)

    Yomi

    2012-03-22

    Mar 22, 2012 ... ambient temperature leads to a delayed implantation and reduced number of implantation sites in. Sprague ... rates decrease after exposure to stress. One of the ..... implantation initiation time, support the previous findings.

  8. Positron implantation profile in kapton

    International Nuclear Information System (INIS)

    Plotkowski, K.; Panek, T.J.; Kansj, J.

    1988-01-01

    Measurements of positrons' implantation profile were made with geometry as in the majority of PAT experiments, making use of the difference in values of mean lifetimes of positrons in the absorber and in the detector. The function describing the absorption of positrons in the absorber taking into account measurement geometry was fitted to the experimental data. The correction to the exponential relation occurring in this function is the dominating factor for small thicknesses of the absorber. In this analysis various values of positrons' backscatter coefficients of the nickel and of the kapton were also taken into account

  9. Optimal Implantable Cardioverter Defibrillator Programming.

    Science.gov (United States)

    Shah, Bindi K

    Optimal programming of implantable cardioverter defibrillators (ICDs) is essential to appropriately treat ventricular tachyarrhythmias and to avoid unnecessary and inappropriate shocks. There have been a series of large clinical trials evaluating tailored programming of ICDs. We reviewed the clinical trials evaluating ICD therapies and detection, and the consensus statement on ICD programming. In doing so, we found that prolonged ICD detection times, higher rate cutoffs, and antitachycardia pacing (ATP) programming decreases inappropriate and painful therapies in a primary prevention population. The use of supraventricular tachyarrhythmia discriminators can also decrease inappropriate shocks. Tailored ICD programming using the knowledge gained from recent ICD trials can decrease inappropriate and unnecessary ICD therapies and decrease mortality.

  10. Fracture dynamics in implanted silicon

    Energy Technology Data Exchange (ETDEWEB)

    Massy, D.; Tardif, S.; Penot, J. D.; Ragani, J.; Rieutord, F. [Univ. Grenoble Alpes, F-38000 Grenoble (France); CEA, INAC-SP2M, F-38000 Grenoble (France); Mazen, F.; Madeira, F. [Univ. Grenoble Alpes, F-38000 Grenoble (France); CEA, LETI, MINATEC Campus, F-38054 Grenoble (France); Landru, D.; Kononchuk, O. [SOITEC, Parc Technologique des Fontaines, 38190 Bernin (France)

    2015-08-31

    Crack propagation in implanted silicon for thin layer transfer is experimentally studied. The crack propagation velocity as a function of split temperature is measured using a designed optical setup. Interferometric measurement of the gap opening is performed dynamically and shows an oscillatory crack “wake” with a typical wavelength in the centimetre range. The dynamics of this motion is modelled using beam elasticity and thermodynamics. The modelling demonstrates the key role of external atmospheric pressure during crack propagation. A quantification of the amount of gas trapped inside pre-existing microcracks and released during the fracture is made possible, with results consistent with previous studies.

  11. Amorphisation during elevated temperature implantation

    International Nuclear Information System (INIS)

    Carter, G.; Nobes, M.J.; Elliman, R.G.

    1994-01-01

    Transition state theory is employed to predict the rates of amorphous zone recrystallization by direct thermal and radiation mediated thermal annealing processes. These rates are functions of zone radius and are employed to describe the competition between amorphous zone generation and annealing during elevated temperature heavy ion implantation of, particularly, Si and the accumulation of amorphousness with increasing ion fluence. This analysis predicts a change from monotonic to sigmoidal to biexponential accumulation functions with increasing annealing rate or substrate temperature in agreement with experiments. A logarithmic dependence of ion flux density upon substrate temperature for the achievement of defined fractional amorphisation is predicted and is also in agreement with the experiment. (author)

  12. Sacroiliac joint stability: Finite element analysis of implant number, orientation, and superior implant length.

    Science.gov (United States)

    Lindsey, Derek P; Kiapour, Ali; Yerby, Scott A; Goel, Vijay K

    2018-03-18

    To analyze how various implants placement variables affect sacroiliac (SI) joint range of motion. An experimentally validated finite element model of the lumbar spine and pelvis was used to simulate a fusion of the SI joint using various placement configurations of triangular implants (iFuse Implant System ® ). Placement configurations were varied by changing implant orientation, superior implant length, and number of implants. The range of motion of the SI joint was calculated using a constant moment of 10 N-m with a follower load of 400 N. The changes in motion were compared between the treatment groups to assess how the different variables affected the overall motion of the SI joint. Transarticular placement of 3 implants with superior implants that end in the middle of the sacrum resulted in the greatest reduction in range of motion (flexion/extension = 73%, lateral bending = 42%, axial rotation = 72%). The range of motions of the SI joints were reduced with use of transarticular orientation (9%-18%) when compared with an inline orientation. The use of a superior implant that ended mid-sacrum resulted in median reductions of (8%-14%) when compared with a superior implant that ended in the middle of the ala. Reducing the number of implants, resulted in increased SI joint range of motions for the 1 and 2 implant models of 29%-133% and 2%-39%, respectively, when compared with the 3 implant model. Using a validated finite element model we demonstrated that placement of 3 implants across the SI joint using a transarticular orientation with superior implant reaching the sacral midline resulted in the most stable construct. Additional clinical studies may be required to confirm these results.

  13. Ion implantation as an efficient surface treatment

    International Nuclear Information System (INIS)

    Straede, C.A.

    1992-01-01

    Ion beam processing has for several years been well established in the semiconductor industry. In recent years ion implantation of tool steels, ceramics and even plastics has gained increasing industrial awareness. The development of ion implantation to a commercially viable surface treatment of tools and spare parts working in production type environments is very dependent on technical merits, economic considerations, competing processes and highly individual barriers to acceptance for each particular application. Some examples of this will be discussed. The development of the process is very closely linked with the development of high current accelerators and their ability to efficiently manipulate the samples being treated, or to make sample manipulation superfluous by using special beam systems like the PSII. Furthermore, the ability to produce high beam currents (mA) of a wide variety of ions is crucial. Previously, it was broadly accepted that ion implantation of tools on a commercial basis generally had to be limited to nitrogen implantation. The development of implanters which can produce high beam currents of ions like B + , C + , Ti + , Cr + and others is rapidly changing this situation, and today an increasing number of commercial implantations are performed with these ions although nitrogen is still successfully used in the majority of commercial implantation. All in all, the recent development of equipment makes it possible to a higher extent than before to tailor the implantation to a specific situation. The emerging new possibilities in this direction will be discussed, and a broad selection of practical examples of ion implantation at standard low temperatures of tools and spare parts will be given. Furthermore, very interesting results have been obtained recently by implanting nitrogen at elevated temperatures, which yields a relatively deep penetration of the implanted ions. (orig./WL)

  14. Tinnitus and Sleep Difficulties After Cochlear Implantation.

    Science.gov (United States)

    Pierzycki, Robert H; Edmondson-Jones, Mark; Dawes, Piers; Munro, Kevin J; Moore, David R; Kitterick, Pádraig T

    To estimate and compare the prevalence of and associations between tinnitus and sleep difficulties in a sample of UK adult cochlear implant users and those identified as potential candidates for cochlear implantation. The study was conducted using the UK Biobank resource, a population-based cohort of 40- to 69-year olds. Self-report data on hearing, tinnitus, sleep difficulties, and demographic variables were collected from cochlear implant users (n = 194) and individuals identified as potential candidates for cochlear implantation (n = 211). These "candidates" were selected based on (i) impaired hearing sensitivity, inferred from self-reported hearing aid use and (ii) impaired hearing function, inferred from an inability to report words accurately at negative signal to noise ratios on an unaided closed-set test of speech perception. Data on tinnitus (presence, persistence, and related distress) and on sleep difficulties were analyzed using logistic regression models controlling for gender, age, deprivation, and neuroticism. The prevalence of tinnitus was similar among implant users (50%) and candidates (52%; p = 0.39). However, implant users were less likely to report that their tinnitus was distressing at its worst (41%) compared with candidates (63%; p = 0.02). The logistic regression model suggested that this difference between the two groups could be explained by the fact that tinnitus was less persistent in implant users (46%) compared with candidates (72%; p reported difficulties with sleep were similar among implant users (75%) and candidates (82%; p = 0.28), but participants with tinnitus were more likely to report sleep difficulties than those without (p explanation is supported by the similar prevalence of sleep problems among implant users and potential candidates for cochlear implantation, despite differences between the groups in tinnitus persistence and related emotional distress. Cochlear implantation may therefore not be an appropriate intervention

  15. Early implant-associated osteomyelitis results in a peri-implanted bacterial reservoir

    DEFF Research Database (Denmark)

    Jensen, Louise Kruse; Koch, Janne; Aalbæk, Bent

    2017-01-01

    weight of Staphylococcus aureus or saline was inserted into the right tibial bone of 12 pigs. The animals were consecutively killed on day 2, 4 and 6 following implantation. Bone tissue around the implant was histologically evaluated. Identification of S. aureus was performed immunohistochemically...... on tissue section and with scanning electron microscopy and peptide nucleic acid in situ hybridization on implants. The distance of the peri-implanted pathological bone area (PIBA), measured perpendicular to the implant, was significantly larger in infected animals compared to controls (p = 0...

  16. CLINICAL CONSIDERATIONS OF DENTAL IMPLANT SYSTEM IN IMMEDIATE LOADING IMPLANT CASES

    Directory of Open Access Journals (Sweden)

    Carolina Damayanti Marpaung

    2015-06-01

    Full Text Available Immediate loading of dental implant has been researched intensively in the development of Branemark’s early concept of 2 stages implant placement. This was embarked from both patients and practiitioner’s convenience towards a simpler protocol and shorter time frame. Many recent researchers later found that micromotions derived from occlusal loading for a certain degree, instead of resulting a fibrous tissue encapsulation, can enhance the osseointegration process. Dental Implant system enhancement towards maximizing the primary stability held a key factor in Branemark’s concept development. Surgical protocol and implant design was found to give a significant contribution to the prognosis of immediate-loading implants.

  17. Novel implant design improves implant survival in multirooted extraction sites: a preclinical pilot study.

    Science.gov (United States)

    Sivan-Gildor, Adi; Machtei, Eli E; Gabay, Eran; Frankenthal, Shai; Levin, Liran; Suzuki, Marcelo; Coelho, Paulo G; Zigdon-Giladi, Hadar

    2014-10-01

    The primary aim is to evaluate clinical, radiographic, and histologic parameters of novel implants with "three roots" design that were inserted into fresh multirooted extraction sockets. A secondary aim is to compare this new implant to standard root-form dental implants. Immediate implantation of novel or standard design 6 × 6-mm implants was performed bilaterally into multirooted sockets in mandibles of mini-pigs. Twelve weeks later, clinical, radiographic, stability, histomorphometric, and microcomputed tomography (micro-CT) analyses were performed. Survival rates were significantly higher in the test implants compared with control (92.8% versus 33.3%, respectively; P micro-CT analyses demonstrated bone fill in the inner part of the test implants. Moreover, bone-to-implant contact was higher in the test implants (55.50% ± 3.68% versus 42.47% ± 9.89%). Contrary to the clinical, radiographic, and histomorphometric results, resonance frequency analysis measurements were greater in the control group (77.74 ± 3.21 implant stability quotient [ISQ]) compared with the test group (31.09 ± 0.28 ISQ), P = 0.008. The novel design implants resulted in significantly greater survival rate in multirooted extraction sites. Further studies will be required to validate these findings.

  18. Influence of prosthesis design and implantation technique on implant stresses after cementless revision THR

    Directory of Open Access Journals (Sweden)

    Duda Georg N

    2011-05-01

    Full Text Available Abstract Background Femoral offset influences the forces at the hip and the implant stresses after revision THR. For extended bone defects, these forces may cause considerable bending moments within the implant, possibly leading to implant failure. This study investigates the influences of femoral anteversion and offset on stresses in the Wagner SL revision stem implant under varying extents of bone defect conditions. Methods Wagner SL revision stems with standard (34 mm and increased offset (44 mm were virtually implanted in a model femur with bone defects of variable extent (Paprosky I to IIIb. Variations in surgical technique were simulated by implanting the stems each at 4° or 14° of anteversion. Muscle and joint contact forces were applied to the reconstruction and implant stresses were determined using finite element analyses. Results Whilst increasing the implant's offset by 10 mm led to increased implant stresses (16.7% in peak tensile stresses, altering anteversion played a lesser role (5%. Generally, larger stresses were observed with reduced bone support: implant stresses increased by as much as 59% for a type IIIb defect. With increased offset, the maximum tensile stress was 225 MPa. Conclusion Although increased stresses were observed within the stem with larger offset and increased anteversion, these findings indicate that restoration of offset, key to restoring joint function, is unlikely to result in excessive implant stresses under routine activities if appropriate fixation can be achieved.

  19. Long range implantation by MEVVA metal ion source

    International Nuclear Information System (INIS)

    Zhang Tonghe; Wu Yuguang; Ma Furong; Liang Hong

    2001-01-01

    Metal vapor vacuum arc (MEVVA) source ion implantation is a new technology used for achieving long range ion implantation. It is very important for research and application of the ion beam modification of materials. The results show that the implanted atom diffusion coefficient increases in Mo implanted Al with high ion flux and high dose. The implanted depth is 311.6 times greater than that of the corresponding ion range. The ion species, doses and ion fluxes play an important part in the long-range implantation. Especially, thermal atom chemistry have specific effect on the long-range implantation during high ion flux implantation at transient high target temperature

  20. Martensite transformation in antimony implanted stainless steel

    International Nuclear Information System (INIS)

    Johnson, E.; Littmark, U.; Johansen, A.; Christodoulides, C.

    1981-01-01

    The authors have used Rutherford backscattering analysis (RBS) and transmission electron microscopy (TEM) and diffraction to investigate austenitic stainless steel crystals implanted at room temperature with 80 keV Sb + ions to a fluence of 5 x 10 20 ions/m 2 , thus providing implantation with a heavy group V element. RBS channeling spectra from implanted crystals show a damage peak which approaches the height of the random level and therefore indicates a very high degree of disorder in the implanted layers. The distribution of the disorder extends to a depth 3-5 times the depth of the primary radiation damage. The Sb peaks under channeling as well as random conditions are indistinguishable, confirming that substitutionality during implantation is negligible. To establish the nature of the disorder which cannot be assessed from the RBS analysis alone, and in particular to assess whether an amorphous alloy is formed in the implanted layer as indicated from the RBS spectra, samples implanted under similar conditions were investigated in the TEM. Significant extra spots in the patterns can be ascribed to the presence of a radiation induced b.c.c. phase of martensitic origin. The result that a significant amount of martensite can be induced by antimony implantation seems to indicate that the main driving force for the transition is due to damage induced stress concentrations. (Auth.)

  1. Laser annealing of ion implanted silicon

    International Nuclear Information System (INIS)

    White, C.W.; Narayan, J.; Young, R.T.

    1978-11-01

    The physical and electrical properties of ion implanted silicon annealed with high powered ruby laser radiation are summarized. Results show that pulsed laser annealing can lead to a complete removal of extended defects in the implanted region accompanied by incorporation of dopants into lattice sites even when their concentration far exceeds the solid solubility limit

  2. Thermal behaviour of nitrogen implanted into zirconium

    International Nuclear Information System (INIS)

    Miyagawa, S.; Ikeyama, M.; Saitoh, K.; Nakao, S.; Niwa, H.; Tanemura, S.; Miyagawa, Y.

    1994-01-01

    Zirconium films were implanted with 15 N ions of energy 50keV to a total fluence of 1x10 18 ionscm -2 in an attempt to study the formation process and thermal stability of ZrN layers produced by high fluence implantation of nitrogen. Subsequent to the implantation at room temperature, samples were annealed at temperatures of 300 C-900 C. The depth profiles of the implanted nitrogen were measured by nuclear reaction analysis using the 15 N(p,αγ) 12 C at E R =429keV, and the surfaces were examined by thin film X-ray diffraction (XRD) and scanning electron microscopy. There were many blisters 0.2-0.4μm in diameter on the surface of the as-implanted samples and double peaks were observed in the nitrogen depth profiles; they were in both sides of the mean projected range. It was found that most of the blisters became extinct after annealing above 400 C, and the XRD peak (111) intensity was increased with the increase in the annealing temperature. Moreover, 14 N and 15 N implantations were superimposed on Zr samples in order to study the atomic migration of nitrogen at each stage of high fluence implantation. It was found that the decrease in the peak at the deeper layers was related to blister extinction and nitrogen diffusion into underling zirconium which could be correlated with radiation damage induced by post-implanted ions. ((orig.))

  3. Magnetoreflection studies of ion implanted bismuth

    International Nuclear Information System (INIS)

    Nicolini, C.; Chieu, T.C.; Dresselhaus, M.S.; Massachusetts Inst. of Tech., Cambridge; Dresselhaus, G.

    1982-01-01

    The effect of the implantation of Sb ions on the electronic structure of the semimetal bismuth is studied by the magnetoreflection technique. The results show long electronic mean free paths and large implantation-induced increases in the band overlap and L-point band gap. These effects are opposite to those observed for Bi chemically doped with Sb. (author)

  4. Wireless Power Transfer Strategies for Implantable Bioelectronics.

    Science.gov (United States)

    Agarwal, Kush; Jegadeesan, Rangarajan; Guo, Yong-Xin; Thakor, Nitish V

    2017-01-01

    Neural implants have emerged over the last decade as highly effective solutions for the treatment of dysfunctions and disorders of the nervous system. These implants establish a direct, often bidirectional, interface to the nervous system, both sensing neural signals and providing therapeutic treatments. As a result of the technological progress and successful clinical demonstrations, completely implantable solutions have become a reality and are now commercially available for the treatment of various functional disorders. Central to this development is the wireless power transfer (WPT) that has enabled implantable medical devices (IMDs) to function for extended durations in mobile subjects. In this review, we present the theory, link design, and challenges, along with their probable solutions for the traditional near-field resonant inductively coupled WPT, capacitively coupled short-ranged WPT, and more recently developed ultrasonic, mid-field, and far-field coupled WPT technologies for implantable applications. A comparison of various power transfer methods based on their power budgets and WPT range follows. Power requirements of specific implants like cochlear, retinal, cortical, and peripheral are also considered and currently available IMD solutions are discussed. Patient's safety concerns with respect to electrical, biological, physical, electromagnetic interference, and cyber security from an implanted neurotech device are also explored in this review. Finally, we discuss and anticipate future developments that will enhance the capabilities of current-day wirelessly powered implants and make them more efficient and integrable with other electronic components in IMDs.

  5. Libyan cochlear implant programme: achievements, difficulties, and ...

    African Journals Online (AJOL)

    Data relating to the patients who received cochlear implantation at Tripoli Medical Centre between October 2007 and February 2010 were analysed. Implant operations were performed on 37 patients. All patients received Med-El SONATATI100 devices. Thirty-four (91.9%) of these patients were children, whilst three (8.1%) ...

  6. Dental implants: A boon to dentistry

    Directory of Open Access Journals (Sweden)

    B H Sripathi Rao

    2015-01-01

    Full Text Available The development and use of implants is one of the biggest advances in dentistry in the last few decades. It has helped to give many solutions to tooth loss as well as maxillo facial prosthetics. This article traces the history and evolution of dental implants.

  7. Wettability control of polystyrene by ion implantation

    International Nuclear Information System (INIS)

    Suzuki, Yoshiaki; Kusakabe, Masahiro; Iwaki, Masaya

    1994-01-01

    The permanent effects of ion implantation on the improvement of wettability of polystyrene is investigated in relation to ion species and fluences. The He + , Ne + , Na + , N 2 + , O 2 + , Ar + , K + and Kr + ion implantations were performed at energies of 50 and 150 keV at room temperature. The fluences ranged from 1x10 15 to 1x10 17 ions/cm 2 . The results showed that the contact angle of water for Na + and K + implanted polystyrene decreased from 87 to 0 , as the fluences increased to 1x10 17 ions/cm 2 at an energy of 50 keV. The contact angle for Na + and K + implanted polystyrene did not change under ambient room conditions, even when time elapsed. However, the contact an gle for He + , C + , O + , Ne + , N 2 + , O 2 + , Ar + , and Kr + ion implanted specimens decreased slightly immediately after ion implantation. Results of X-ray photoelectron spectroscopy showed that the increase in the Na content in the surface of Na + implanted specimens were observed with increasing fluence. It is concluded that permanent improvement in wettability was caused by doping effects rather than by radiation effects from Na + and K + ion implantation. ((orig.))

  8. Electroconvulsive therapy after maxillofacial metallic implants.

    Science.gov (United States)

    Freeman, G Mark; Perry, Matthew T; Manatt, George S; Cristancho, Pilar

    2014-03-01

    A growing body of literature suggests that electroconvulsive therapy (ECT) can be safely utilized in patients with craniofacial metallic implants. Here we provide radiographic images and the clinical course of a 49-year-old woman with both maxillary and mandibular metallic implants who safely received ECT.

  9. Biomimetic implants for pelvic floor repair

    NARCIS (Netherlands)

    Vashaghian, Mahshid; Zaat, Sebastianus A. J.; Smit, Theodoor H.; Roovers, Jan-Paul

    2017-01-01

    Polypropylene implants are used for the reconstructive surgery of urogynaecological disorders like pelvic organ prolapse, but severe complications associated with their use have been reported. There is evidence that surface properties and a difference in mechanical stiffness between the implant and

  10. Oral Abstract Session 3: Orthognathic/Implants

    DEFF Research Database (Denmark)

    Hartlev, Jens

    Immediate Placement And Provisionalization Of Single-tooth Implants Involving A Final Individual Abutment. A 3-year Clinical And Radiographic Retrospektive Study......Immediate Placement And Provisionalization Of Single-tooth Implants Involving A Final Individual Abutment. A 3-year Clinical And Radiographic Retrospektive Study...

  11. Biofilm and dental implant: The microbial link

    Directory of Open Access Journals (Sweden)

    Sangeeta Dhir

    2013-01-01

    Full Text Available Mouth provides a congenial environment for the growth of the microorganisms as compared to any other part of the human body by exhibiting an ideal nonshedding surface. Dental plaque happens to be a diverse community of the microorganisms found on the tooth surface. Periodontal disease and the peri-implant disease are specific infections that are originating from these resident microbial species when the balance between the host and the microbial pathogenicity gets disrupted. This review discusses the biofilms in relation to the peri-implant region, factors affecting its presence, and the associated treatment to manage this complex microbial colony. Search Methodology: Electronic search of the medline was done with the search words: Implants and biofilms/dental biofilm formation/microbiology at implant abutment interface/surface free energy/roughness and implant, periimplantitis/local drug delivery and dental implant. Hand search across the journals - clinical oral implant research, implant dentistry, journal of dental research, international journal of oral implantology, journal of prosthetic dentistry, perioodntology 2000, journal of periodontology were performed. The articles included in the review comprised of in vivo studies, in vivo (animal and human studies, abstracts, review articles.

  12. Simplifying cochlear implant speech processor fitting

    NARCIS (Netherlands)

    Willeboer, C.

    2008-01-01

    Conventional fittings of the speech processor of a cochlear implant (CI) rely to a large extent on the implant recipient's subjective responses. For each of the 22 intracochlear electrodes the recipient has to indicate the threshold level (T-level) and comfortable loudness level (C-level) while

  13. Osseoperception in Dental Implants: A Systematic Review.

    Science.gov (United States)

    Mishra, Sunil Kumar; Chowdhary, Ramesh; Chrcanovic, Bruno Ramos; Brånemark, Per-Ingvar

    2016-04-01

    Replacement of lost teeth has significant functional and psychosocial effects. The capability of osseointegrated dental implants to transmit a certain amount of sensibility is still unclear. The phenomenon of developing a certain amount of tactile sensibility through osseointegrated dental implants is called osseoperception. The aim of this article is to evaluate the available literature to find osseoperception associated with dental implants. To identify suitable literature, an electronic search was performed using Medline and PubMed database. Articles published in English and articles whose abstract is available in English were included. The articles included in the review were based on osseoperception, tactile sensation, and neurophysiological mechanoreceptors in relation to dental implants. Articles on peri-implantitis and infection-related sensitivity were not included. Review articles without the original data were excluded, although references to potentially pertinent articles were noted for further follow-up. The phenomenon of osseoperception remains a matter of debate, so the search strategy mainly focused on articles on osseoperception and tactile sensibility of dental implants. This review presents the histological, neurophysiological, and psychophysical evidence of osseoperception and also the role of mechanoreceptors in osseoperception. The literature on osseoperception in dental implants is very scarce. The initial literature search resulted in 90 articles, of which 81 articles that fulfilled the inclusion criteria were included in this systematic review. Patients restored with implant-supported prostheses reported improved tactile and motor function when compared with patients wearing complete dentures. © 2016 by the American College of Prosthodontists.

  14. Polymeric implant of methylprednisolone for spinal injury ...

    African Journals Online (AJOL)

    Polymeric implant of methylprednisolone for spinal injury: preparation and characterization. Bo Yin, Jian-Jun Ji, Ming Yang. Abstract. Purpose: To improve the effectiveness and reduce the systemic side effects of methylprednisolone in traumatic spinal injuries, its polymeric implants were prepared using chitosan and sodium ...

  15. Systemic Assessment of Patients Undergoing Dental Implant ...

    African Journals Online (AJOL)

    Background: Procedure‑related and patient‑related factors influence the prognosis of dental implants to a major extent. Hence, we aimed to evaluate and analyze various systemic factors in patients receiving dental implants. Materials and Methods: Fifty‑one patients were included in the study, in which a total of 110 dental ...

  16. Systemic Assessment of Patients Undergoing Dental Implant ...

    African Journals Online (AJOL)

    These days, dental implants are becoming routinely used as a treatment option for rehabilitation of lost teeth. Conventionally, it is only after the completion of bone healing that the dental implants are loaded into the bone. Bone healing time is approximately 3 months and. 6 months for the mandible and maxilla, respectively.

  17. Different encapsulation strategies for implanted electronics

    Directory of Open Access Journals (Sweden)

    Winkler Sebastian

    2017-09-01

    Full Text Available Recent advancements in implant technology include increasing application of electronic systems in the human body. Hermetic encapsulation of electronic components is necessary, specific implant functions and body environments must be considered. Additional functions such as wireless communication systems require specialized technical solutions for the encapsulation.

  18. Physical Properties of Silicone Gel Breast Implants.

    Science.gov (United States)

    Jewell, Mark L; Bengtson, Bradley P; Smither, Kate; Nuti, Gina; Perry, TracyAnn

    2018-04-28

    Surgical applications using breast implants are individualized operations to fill and shape the breast. Physical properties beyond shape, size, and surface texture are important considerations during implant selection. Compare form stability, gel material properties, and shell thickness of textured shaped, textured round, and smooth round breast implants from 4 manufacturers: Allergan, Mentor, Sientra, and Establishment Labs through bench testing. Using a mandrel height gauge, form stability was measured by retention of dimensions on device movement from a horizontal to vertical supported orientation. Dynamic response of gel material (gel cohesivity, resistance to gel deformation, energy absorption) was measured using a synchronized target laser following application of graded negative pressure. Shell thickness was measured using digital thickness gauge calipers. Form stability, gel material properties, and shell thickness differed across breast implants. Of textured shaped devices, Allergan Natrelle 410 exhibited greater form stability than Mentor MemoryShape and Sientra Shaped implants. Allergan Inspira round implants containing TruForm 3 gel had greater form stability, higher gel cohesivity, greater resistance to gel deformation, and lower energy absorption than those containing TruForm 2 gel and in turn, implants containing TruForm 1 gel. Shell thickness was greater for textured versus smooth devices, and differed across styles. Gel cohesivity, resistance to gel deformation, and energy absorption are directly related to form stability, which in turn determines shape retention. These characteristics provide information to aid surgeons choosing an implant based on surgical application, patient tissue characteristics, and desired outcome.

  19. Quality assessment of pacemaker implantations in Denmark

    DEFF Research Database (Denmark)

    Møller, M; Arnsbo, P; Asklund, Mogens

    2002-01-01

    AIMS: Quality assessment of therapeutic procedures is essential to insure a cost-effective health care system. Pacemaker implantation is a common procedure with more than 500,000 implantations world-wide per year, but the general complication rate is not well described. We studied procedure relat...

  20. Deafblind People's Experiences of Cochlear Implantation

    Science.gov (United States)

    Soper, Janet

    2006-01-01

    Cochlear implants are electronic devices that create the sensation of hearing in those who cannot obtain any benefit from conventional hearing aids. This article examines the experience of cochlear implantation in a select group of individuals with acquired deafblindness, focusing on three key themes: access to communication, information and…

  1. Niobium stainless steel for implants

    International Nuclear Information System (INIS)

    Rollo, J.M.D.A.

    1983-01-01

    The materials that have often been used, during the last two or three decades, to carry out materials for implants are made according to the specifications: a)A.S.T.M. (F.55-76, F.56-76, F.138-76, F.139-76) stainless steel b)A.S.T.M. (F.75-76), cobalt-chromium-molybdenum alloys. c)A.S.T.M. (F.90-76), cobalt-chromium-tungsten-nickel alloys. d)A.S.T.M. (F.67-77), unalloyed titanium. e)A.S.T.M. (F.136-70), titanium alloys. It was the purpose of retaking them, toverify the niobium influence as alloy element in ANSI/ASTM F.55-76 classification stainless steels, usually for these materials elaboration. The problem by substituting molybdenum total or partially for niobium, by comparing the mechanical and corrosion properties, and biocompatibility is presented, by pointing out the variables of these substitutions, when we employ this new material to perform materials for implants. (Author) [pt

  2. Diclofenac Sodium Loaded Multicomponent Implant

    Science.gov (United States)

    Nikkola, Lila; Viitanen, Petrus; Ashammakhi, Nureddin

    2008-02-01

    Earlier we have reported on developing DS releasing bioabsorbable rods for inhibition of osteolysis [l]. Due to their unsatisfactory drug release profiles we assessed the use of sintering technique of enhancement of drug release in the current study. Melt extruded PLGA 80/20 rods were compounded 8 wt-% DS. Some rods were self reinforced (SR) and some of them were sterilized to get three different components with different drug release profiles. Different rods were sintered together with heat and pressure. Three different specimen groups with different construction were studied. Thermal properties were analyzed using differential scanning calorimetry (DSC). Changes of IV were performed with capillary analysis and drug release measurements with UV-Vis spectrophotometer. Mechanical strength were measured two weeks, when disintegration occurred. Release rate consisted of 1) sharp jump start peak, 2) second smoother peak, and 3) third smooth peak. Released DS concentrations reached local therapeutic levels and maintained at that stage for 24-36 days. All DS was released during 50-70 days. The drug release from multicomponent implant was more stable and commenced earlier than from initial rods. Such properties were favored ones. Initial shear strength was 82 MPa and it decreased to 15 MPa. The mechanical bonding was sufficient although the components disintegrated relatively fast. By sintering different PLGA/DS components with different release rates it is possible to construct a truly controlled release implant for bone fixation with anti-inflammatory properties.

  3. Impact of cone-beam computed tomography on implant planning and on prediction of implant size

    International Nuclear Information System (INIS)

    Pedroso, Ludmila Assuncao de Mello; Silva, Maria Alves Garcia Santos; Garcia, Robson Rodrigues; Leles, Jose Luiz Rodrigues; Leles, Claudio Rodrigues

    2013-01-01

    The aim was to investigate the impact of cone-beam computed tomography (CBCT) on implant planning and on prediction of final implant size. Consecutive patients referred for implant treatment were submitted to clinical examination, panoramic (PAN) radiography and a CBCT exam. Initial planning of implant length and width was assessed based on clinical and PAN exams, and final planning, on CBCT exam to complement diagnosis. The actual dimensions of the implants placed during surgery were compared with those obtained during initial and final planning, using the McNemmar test (p 0.05). It was concluded that CBCT improves the ability of predicting the actual implant length and reduces inaccuracy in surgical dental implant planning. (author)

  4. Bilateral Poly Implant Prothèse Implant Rupture: An Uncommon Presentation

    Directory of Open Access Journals (Sweden)

    Peter Mallon

    2013-07-01

    Full Text Available Summary: A woman in her 50s underwent delayed bilateral Poly Implant Prothèse implant reconstruction following mastectomy for breast cancer. Symptoms of implant rupture developed 43 months after surgery with an erythematous rash on her trunk. The rash then spread to her reconstructed breast mounds. Initial ultrasound scan and magnetic resonance imaging were normal; however, subsequent magnetic resonance imaging demonstrated left implant rupture only. In theater, following removal of both implants, both were found to be ruptured. The rash on her trunk resolved within 3 weeks in the postoperative period. Chemical analyses of silicone in both implants confirmed a nonauthorized silicone source; in addition, the chemical structure was significantly different between the left and right implant, perhaps explaining the variation in presentation.

  5. Current status of grafts and implants in rhinoplasty: Part II. Homologous grafts and allogenic implants.

    Science.gov (United States)

    Sajjadian, Ali; Naghshineh, Nima; Rubinstein, Roee

    2010-03-01

    After reading this article, the participant should be able to: 1. Understand the challenges in restoring volume and structural integrity in rhinoplasty. 2. Identify the appropriate uses of various homologous grafts and allogenic implants in reconstruction, including: (a) freeze-dried acellular allogenic cadaveric dermis grafts, (b) irradiated cartilage grafts, (c) hydroxyapatite mineral matrix, (d) silicone implants, (e) high-density polyethylene implants, (f) polytetrafluoroethylene implants, and (g) injectable filler materials. 3. Identify the advantages and disadvantages of each of these biomaterials. 4. Understand the specific techniques that may aid in the use these grafts or implants. This review specifically addresses the use of homologous grafts and allogenic implants in rhinoplasty. It is important to stress that autologous materials remain the preferred graft material for use in rhinoplasty, owing to their high biocompatibility and low risk of infection and extrusion. However, concerns of donor-site morbidity, graft availability, and graft resorption have motivated the development and use of homologous and allogenic implants.

  6. Ion Implantation and Synthesis of Materials

    CERN Document Server

    Nastasi, Michael

    2006-01-01

    Ion implantation is one of the key processing steps in silicon integrated circuit technology. Some integrated circuits require up to 17 implantation steps and circuits are seldom processed with less than 10 implantation steps. Controlled doping at controlled depths is an essential feature of implantation. Ion beam processing can also be used to improve corrosion resistance, to harden surfaces, to reduce wear and, in general, to improve materials properties. This book presents the physics and materials science of ion implantation and ion beam modification of materials. It covers ion-solid interactions used to predict ion ranges, ion straggling and lattice disorder. Also treated are shallow-junction formation and slicing silicon with hydrogen ion beams. Topics important for materials modification, such as ion-beam mixing, stresses, and sputtering, are also described.

  7. Importance of cochlear health for implant function.

    Science.gov (United States)

    Pfingst, Bryan E; Zhou, Ning; Colesa, Deborah J; Watts, Melissa M; Strahl, Stefan B; Garadat, Soha N; Schvartz-Leyzac, Kara C; Budenz, Cameron L; Raphael, Yehoash; Zwolan, Teresa A

    2015-04-01

    Amazing progress has been made in providing useful hearing to hearing-impaired individuals using cochlear implants, but challenges remain. One such challenge is understanding the effects of partial degeneration of the auditory nerve, the target of cochlear implant stimulation. Here we review studies from our human and animal laboratories aimed at characterizing the health of the implanted cochlea and the auditory nerve. We use the data on cochlear and neural health to guide rehabilitation strategies. The data also motivate the development of tissue-engineering procedures to preserve or build a healthy cochlea and improve performance obtained by cochlear implant recipients or eventually replace the need for a cochlear implant. This article is part of a Special Issue entitled . Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Surface modification of metals by ion implantation

    International Nuclear Information System (INIS)

    Iwaki, Masaya

    1988-01-01

    Ion implantation in metals has attracted the attention as a useful technology for the formation of new metastable alloys and compounds in metal surface layers without thermal equilibrium. Current studies of metal surface modification by ion implantation with high fluences have expanded from basic research areas and to industrial applications for the improvement of life time of tools. Many results suggest that the high fluence implantation produces the new surface layers with un-expected microscopic characteristics and macroscopic properties due to implant particles, radiation damage, sputtering, and knock-on doping. In this report, the composition, structure and chemical bonding state in surface layers of iron, iron-based alloy and aluminum sheets implanted with high fluences have been investigated by means of secondary ion mass spectroscopy (SIMS), Auger electron spectroscopy (AES), X-ray photoelectron spectroscopy (XPS) and transmission electron microscopy (TEM). Tribological properties such as hardness, friction and wear are introduced. (author)

  9. Mutagenic effects of ion implantation on stevia

    International Nuclear Information System (INIS)

    Wang Cailian; Shen Mei; Chen Qiufang; Lu Ting; Shu Shizhen

    1998-01-01

    Dry seeds of Stevia were implanted by 75 keV nitrogen and carbon ions with various doses. The biological effects in M 1 and mutation in M 2 were studied. The results showed that ion beam was able to induce variation on chromosome structure in root tip cells. The rate of cells with chromosome aberration was increased with ion beam dose. The rate of cells with chromosomal aberration was lower than that induced with γ-rays. Frequency of the mutation induced by implantation of N + and C + ions were higher than those induced by γ-rays. The rate of cell with chromosome aberration and in M 2 useful mutation induced by implantation of C + ion was higher than those induced by implantation of N + ion. Mutagenic effects Feng 1 x Riyuan and Riyuan x Feng 2 by implantation of N + and C + were higher than that of Jining and Feng 2

  10. Study of hydrogen implanted in aluminium

    International Nuclear Information System (INIS)

    Bugeat, J.P.; Chami, A.C.; Danielou, R.; Ligeon, E.

    1976-01-01

    An aluminium sample was implanted with deuterium and hydrogen at 5keV and 10keV respectively. The 1 H( 11 B,α) 8 Be* and D( 3 He,p) 4 He reactions were used for the analysis of H and D respectively. The implanted deuterium was shown to be as a whole in a tetrahedral site as far as the implantation temperature is lower than 175K, beyond that temperature the deuterium is randomly located. When the implantation temperature increases from 33K up to 275K the tetrahedral siting remains during annealing. The migration temperatures of hydrogen (or temperature of transition from the tetrahedral siting to a random distribution) experimentally observed during annealing (300K) and for increased implantation temperatures, show that the tetrahedral site is associated with a monovacancy migrating at 300K, the diffusion temperature of hydrogen being lower than 180K [fr

  11. Hydrogenation of stainless steels implanted with nitrogen

    International Nuclear Information System (INIS)

    Silva Ramos, L.E. da.

    1989-01-01

    In the present work the effects of both ion implantation and hydrogenation on the fatigue behaviour of an AISI-304 type unstable stainless steel was studied. The material was tested under the following microstructural conditions: annealed; annealed plus hydrogenated; annealed plus ion-implanted; annealed, ion-implanted and hydrogeneted. The hydrogen induced phase transformations were also studied during the outgassing of the samples. The ion implanted was observed to retard the kinetics of the hydrogen induced phase transformations. It was also observed that the nitrogen ion implantation followed by both natural (for about 4 months) and artificial (100 0 C for 6 hours) aging treatments was beneficial to the fatigue life of both non hydrogenated and severely hydrogenated samples. (author) [pt

  12. High-energy ion implantation of materials

    International Nuclear Information System (INIS)

    Williams, J.M.

    1991-11-01

    High-energy ion implantation is an extremely flexible type of surface treatment technique, in that it offers the possibility of treating almost any type of target material or product with ions of almost any chemical species, or combinations of chemical species. In addition, ion implantations can be combined with variations in temperature during or after ion implantation. As a result, the possibility of approaching a wide variety of surface-related materials science problems exists with ion implantation. This paper will outline factors pertinent to application of high-energy ion implantation to surface engineering problems. This factors include fundamental advantages and limitations, economic considerations, present and future equipment, and aspects of materials science

  13. Diagnostic Imaging for Dental Implant Therapy

    Directory of Open Access Journals (Sweden)

    Aishwarya Nagarajan

    2014-01-01

    Full Text Available Dental implant is a device made of alloplastic (foreign material implanted into the jaw bone beneath the mucosal layer to support a fixed or removable dental prosthesis. Dental implants are gaining immense popularity and wide acceptance because they not only replace lost teeth but also provide permanent restorations that do not interfere with oral function or speech or compromise the self-esteem of a patient. Appropriate treatment planning for replacement of lost teeth is required and imaging plays a pivotal role to ensure a satisfactory outcome. The development of pre-surgical imaging techniques and surgical templates helps the dentist place the implants with relative ease. This article focuses on various types of imaging modalities that have a pivotal role in implant therapy.

  14. Selenium implantation in epitaxial gallium arsenide layers

    International Nuclear Information System (INIS)

    Inada, T.; Tokunaga, K.; Taka, S.; Yuge, Y.; Kohzu, H.

    1981-01-01

    Selenium implantation at room temperature in S-doped epitaxial GaAs layers as a means of the formation of n + layers has been investigated. Doping profiles for Se-implanted layers have been examined by a C-V technique and/or a differential Hall effect method. It has been shown that n + layers with a maximum carrier concentration of approx. equal to1.5 x 10 18 cm -3 can be formed by implantation followed by a 15 min annealing at 950 0 C. Contact resistance of ohmic electrodes is reduced by use of the Se-implanted n + layers, resulting in the improvement on GaAs FET performance. Measured minimum noise figure of the Se-implanted GaAs FETs is 0.74 dB at 4 GHz. (orig.)

  15. Experimental study on bone tissue reaction around HA implants radiated after implantation

    International Nuclear Information System (INIS)

    Kudo, Masato; Matsui, Yoshiro; Tamura, Sayaka; Chen, Xuan; Uchida, Haruo; Mori, Kimie; Ohno, Kohsuke; Michi, Ken-ichi

    1998-01-01

    This study was conducted to investigate histologically and histomorphometrically the tissue reaction around hydroxylapatite (HA) implants that underwent irradiation in 3 different periods in the course of bone healing after implantation. The cylindrical high-density HA implants were implanted in 48 Japanese white rabbit mandibles. A single 15 Gy dose was applied to the mandible 5, 14, or 28 days after implantation. The rabbits were sacrificed 7, 14, 28, and 90 days after irradiation. Nonirradiated rabbits were used as controls. CMR, labeling with tetracycline and calcein, and non-decalcified specimens stained with toluidine blue were used for histological analyses and histomorphometric measurements. The results were as follows: In the rabbits irradiated 5 days after implantation, the HA-bone contact was observed later than that in the controls and the bone-implant contact surface ratio was lower than that in the controls at examination because necrosis of the newly-formed bone occurred just after irradiation. HA-bone contact of the rabbits irradiated 14 and 28 days after implantation was similar to that of the controls. And, bone remodeling was suppressed in rabbits of each group sacrificed at 90 days after irradiation. The results suggested that a short interval between implantation and irradiation causes direct contact between HA implant and bone and a long lapse of time before irradiation hardly affects the bone-implant contact, but delays bone remodeling. Therefore, it is necessary to prevent overloading the HA implants irradiated after implantation and pay utmost attention to conditions around the bone-implant contact. (author)

  16. Surface characterization of titanium based dental implants; Caracterizacao de implantes odontologicos a base de titanio

    Energy Technology Data Exchange (ETDEWEB)

    Castilho, Guilherme Augusto Alcaraz

    2006-07-01

    Dental implantology uses metallic devices made of commercially pure titanium in order to replace lost teeth. Titanium presents favorable characteristics as bio material and modern implants are capable of integrate, witch is the union between bone and implant without fibrous tissue development. Three of the major Brazilian implant manufacturers were chosen to join the study. A foreign manufacturer participated as standard. The manufacturers had three specimens of each implant with two different surface finishing, as machined and porous, submitted to analysis. Surface chemical composition and implant morphology were analyzed by X-ray photoelectron spectroscopy (XP S), scanning electron microscopy (SEM) and microprobe. Implant surface is mainly composed of titanium, oxygen and carbon. Few contaminants commonly present on implant surface were found on samples. Superficial oxide layer is basically composed of titanium dioxide (TiO{sub 2}), another oxides as Ti O and Ti{sub 2}O{sub 3} were also found in small amount. Carbon on implant surface was attributed to manufacturing process. Nitrogen, Phosphorous and Silicon appeared in smaller concentration on surface. There was no surface discrepancy among foreign and Brazilian made implants. SEM images were made on different magnification, 35 X to 3500 X, and showed similarity among as machined implants. Porous surface finishing implants presented distinct morphology. This result was attributed to differences on manufacturing process. Implant bioactivity was accessed through immersion on simulated body solution (SBF) in order to verify formation of an hydroxyapatite (HA) layer on surface. Samples were divided on three groups according to immersion time: G1 (7 days), G2 (14 days), G3 (21 days), and deep in SBF solution at 37 deg C. After being removed from solution, XPS analyses were made and then implants have been submitted to microprobe analysis. XPS showed some components of SBF solution on sample surface but microprobe

  17. Effect of implant position, angulation, and attachment height on peri-implant bone stress associated with mandibular two-implant overdentures: a finite element analysis.

    Science.gov (United States)

    Hong, Hae Ryong; Pae, Ahran; Kim, Yooseok; Paek, Janghyun; Kim, Hyeong-Seob; Kwon, Kung-Rock

    2012-01-01

    The aim of this study was to analyze and compare the level and distribution of peri-implant bone stresses associated with mandibular two-implant overdentures with different implant positions. Mathematical models of mandibles and overdentures were designed using finite element analysis software. Two intraosseous implants and ball attachment systems were placed in the interforaminal region. The overdenture, which was supported by the two implants, was designed to withstand bilateral and unilateral vertical masticatory loads (total 100 N). In all, eight types of models, which differed according to assigned implant positions, height of attachments, and angulation, were tested: MI (model with implants positioned in the lateral incisor sites), MC (implants in canine sites), MP (implants in premolar sites), MI-Hi (greater height of attachments), MC-M (canine implants placed with mesial inclination), MC-D (canine implants placed with distal inclination), MC-B (canine implants placed with buccal inclination), and MC-L (canine implants placed with lingual inclination). Peri-implant bone stress levels associated with overdentures retained by lateral incisor implants resulted in the lowest stress levels and the highest efficiency in distributing peri-implant stress. MI-Hi showed increased stress levels and decreased efficiency in stress distribution. As the implants were inclined, stress levels increased and the efficiency of stress distribution decreased. Among the inclined models, MC-B showed the lowest stress level and best efficiency in stress distribution. The lowest stress and the best stability of implants in mandibular two-implant overdentures were obtained when implants were inserted in lateral incisor areas with shorter attachments and were placed parallel to the long axes of the teeth.

  18. Are short implants in the mandible safe?

    Directory of Open Access Journals (Sweden)

    Sergio Henrique Gonçalves Motta

    2009-10-01

    Full Text Available Objective: To analyze the importance of bioengineering and the improvement in surgical techniques demonstrated by the rates attained of the prevalence of successful placement of dental implants in the posterior region of the mandible, in D3 bone quality in patients between the ages of 52 and 60 years, with dentures fixed on 8.5 mm implants. Methods: The statistical data for this retrospective study were collected at the Post-Graduation Center of the Integrated Dentistry Center, Faculty of Sarandi / Academy of Dentistry - Rio de Janeiro, at the CLIVO clinic, from among a total of 2.294 implants placed in the mandible, in the period from 1999 to 2007. There was a total of 1.056 short implants, of a length shorter than or equal to 10 mm, among which 20 implants were randomly chosen and analyzed. Results: The data were treated statistically and comparison of these data was consubstantiated in constructive data analysis by means of Statistical Pattern Recognition Methods for each variable under study. A success rate of 85% was obtained, and the need to take certain care when indicating the use of short implants was verified. Conclusion: Bioengineering and the development of present day surgical techniques have optimized the use of short implants, with the aim of avoiding advanced surgeries. To compensate the smaller size, there are some factors that must be observed, such as: Bone quality, crown/implant ratio, number and diameter of implants, macroscopic and microscopic geometry of the implants, magnitude of mesial occlusal forces.

  19. Soft tissue grafting to improve implant esthetics

    Directory of Open Access Journals (Sweden)

    Moawia M Kassab

    2010-09-01

    Full Text Available Moawia M KassabDivision of Periodontics, Marquette University, School of Dentistry, Milwaukee, WI, USAAbstract: Dental implants are becoming the treatment of choice to replace missing teeth, especially if the adjacent teeth are free of restorations. When minimal bone width is present, implant placement becomes a challenge and often resulting in recession and dehiscence around the implant that leads to subsequent gingival recession. To correct such defect, the author turned to soft tissue autografting and allografting to correct a buccal dehiscence around tooth #24 after a malpositioned implant placed by a different surgeon. A 25-year-old woman presented with the chief complaint of gingival recession and exposure of implant threads around tooth #24. The patient received three soft tissue grafting procedures to augment the gingival tissue. The first surgery included a connective tissue graft to increase the width of the keratinized gingival tissue. The second surgery included the use of autografting (connective tissue graft to coronally position the soft tissue and achieve implant coverage. The third and final surgery included the use of allografting material Alloderm to increase and mask the implant from showing through the gingiva. Healing period was uneventful for the patient. After three surgical procedures, it appears that soft tissue grafting has increased the width and height of the gingiva surrounding the implant. The accomplished thickness of gingival tissue appeared to mask the showing of implant threads through the gingival tissue and allowed for achieving the desired esthetic that the patient desired. The aim of the study is to present a clinical case with soft tissue grafting procedures.Keywords: case report, connective tissue, dental implants, allograft, coronally positioned flap

  20. MR images of rupture and leakage of breast implants

    International Nuclear Information System (INIS)

    Fang Ling; Liu Pengcheng; Huang Rong; Hu Huaxin; Chen Zaizhong; Du Duanming; Liu Hanqiao; Feng Fei

    2002-01-01

    Objective: To investigate the diagnostic value of magnetic resonance imaging in detecting rupture and leakage of breast implants. Methods: Seventeen cases with breast implants were imaged by MR scanner. 1 normal silicone breast implant outside the body was scanned by MR as an consultative standard. MR images of silicone implants and polypropylene acyl amine implants were classified and analyzed. Results: In 7 cases, 12 single lumen silicone implants were intact, among them 8 were silicone gel-filled implants, 4 were physiological saline-filled implants. 2 physiological saline-filled implants ruptured, among them 1 belonged to intracapsular silicone implant rupture with subsided silicone gel capsule which presented as long T 1 signal and short T 2 signal on MR images; The other belonged to extracapsular silicone implant rapture with physiological saline granule outside breast on MR images. 20 breast implants in 10 cases were injected by polypropylene acyl amine, among them 2 breast implants were intact, 16 breast implants ruptured completely with pieces and nodes of long T 1 signal and long T 2 signal on MR images, 14 of 16 also presented polypropylene acyl amine granule outside breast; 2 breast implants splited inside with linguine sign. Conclusion: The magnetic resonance imaging can make clear the type and the seat of breast implants, the type of rupture of breast implants, and the distribution of leakage material. Therefore magnetic resonance imaging can be an effective guidance for clinical operation and can be an consultative standard for follow-up

  1. Histology of a dental implant with a platform switched implant-abutment connection

    Directory of Open Access Journals (Sweden)

    Vittoria Perrotti

    2011-10-01

    Full Text Available Background: Peri-implant crestal bone must be stable for aesthetic reasons. Aim of this study was a histologic analysis of an implant with a platform switched implant-abutment connection. Materials and methods: A 32-year-old male patient participated in this study. The patient needed a bilateral mandibular restoration. Four implants were used, and were immediately restored and loaded the same day of insertion. After a 6 weeks healing period, one implant with platform-switched abutment was retrieved with trephine. Before retrieval the implant was osseointegrated and not mobile. On one side of the implant, a 1 mm resorption of the crestal bone was present. On the contrary, on the other side no bone resorption had occurred and about 1 mm of bone was present over the implant shoulder. Results: The bone-implant contact percentage was 65.1 ± 6.3 %. Platform- switching could help in maintaining the height of the peri-implant crestal bone.

  2. The clinical implications of poly implant prothèse breast implants: an overview.

    Science.gov (United States)

    Wazir, Umar; Kasem, Abdul; Mokbel, Kefah

    2015-01-01

    Mammary implants marketed by Poly Implant Prothèse (PIP) were found to contain industrial grade silicone and this caused heightened anxiety and extensive publicity regarding their safety in humans. These implants were used in a large number of patients worldwide for augmentation or breast reconstruction. We reviewed articles identified by searches of Medline, PubMed, Embase, and Google Scholar databases up to May 2014 using the terms: "PIP", "Poly Implant Prothèse", "breast implants" and "augmentation mammoplasty" "siloxanes" or "silicone". In addition the websites of regulating bodies in Europe, USA, and Australia were searched for reports related to PIP mammary implants. PIP mammary implants are more likely to rupture than other implants and can cause adverse effects in the short to the medium term related to the symptoms of rupture such as pain, lumps in the breast and axilla and anxiety. Based on peer-reviewed published studies we have calculated an overall rupture rate of 14.5% (383/2,635) for PIP implants. However, there is no evidence that PIP implant rupture causes long-term adverse health effects in humans so far. Silicone lymphadenopathy represents a foreign body reaction and should be treated conservatively. The long-term adverse effects usually arise from inappropriate extensive surgery, such as axillary lymph node dissection or extensive resection of breast tissue due to silicone leakage.

  3. The Clinical Implications of Poly Implant Prothèse Breast Implants: An Overview

    Directory of Open Access Journals (Sweden)

    Umar Wazir

    2015-01-01

    Full Text Available Mammary implants marketed by Poly Implant Prothèse (PIP were found to contain industrial grade silicone and this caused heightened anxiety and extensive publicity regarding their safety in humans. These implants were used in a large number of patients worldwide for augmentation or breast reconstruction. We reviewed articles identified by searches of Medline, PubMed, Embase, and Google Scholar databases up to May 2014 using the terms: "PIP", "Poly Implant Prothèse", "breast implants" and "augmentation mammoplasty" "siloxanes" or "silicone". In addition the websites of regulating bodies in Europe, USA, and Australia were searched for reports related to PIP mammary implants. PIP mammary implants are more likely to rupture than other implants and can cause adverse effects in the short to the medium term related to the symptoms of rupture such as pain, lumps in the breast and axilla and anxiety. Based on peer-reviewed published studies we have calculated an overall rupture rate of 14.5% (383/2,635 for PIP implants. However, there is no evidence that PIP implant rupture causes long-term adverse health effects in humans so far. Silicone lymphadenopathy represents a foreign body reaction and should be treated conservatively. The long-term adverse effects usually arise from inappropriate extensive surgery, such as axillary lymph node dissection or extensive resection of breast tissue due to silicone leakage.

  4. Osseointegration of zirconia implants: an SEM observation of the bone-implant interface.

    Science.gov (United States)

    Depprich, Rita; Zipprich, Holger; Ommerborn, Michelle; Mahn, Eduardo; Lammers, Lydia; Handschel, Jörg; Naujoks, Christian; Wiesmann, Hans-Peter; Kübler, Norbert R; Meyer, Ulrich

    2008-11-06

    The successful use of zirconia ceramics in orthopedic surgery led to a demand for dental zirconium-based implant systems. Because of its excellent biomechanical characteristics, biocompatibility, and bright tooth-like color, zirconia (zirconium dioxide, ZrO2) has the potential to become a substitute for titanium as dental implant material. The present study aimed at investigating the osseointegration of zirconia implants with modified ablative surface at an ultrastructural level. A total of 24 zirconia implants with modified ablative surfaces and 24 titanium implants all of similar shape and surface structure were inserted into the tibia of 12 Göttinger minipigs. Block biopsies were harvested 1 week, 4 weeks or 12 weeks (four animals each) after surgery. Scanning electron microscopy (SEM) analysis was performed at the bone implant interface. Remarkable bone attachment was already seen after 1 week which increased further to intimate bone contact after 4 weeks, observed on both zirconia and titanium implant surfaces. After 12 weeks, osseointegration without interposition of an interfacial layer was detected. At the ultrastructural level, there was no obvious difference between the osseointegration of zirconia implants with modified ablative surfaces and titanium implants with a similar surface topography. The results of this study indicate similar osseointegration of zirconia and titanium implants at the ultrastructural level.

  5. Influence of controlled immediate loading and implant design on peri-implant bone formation.

    Science.gov (United States)

    Vandamme, Katleen; Naert, Ignace; Geris, Liesbet; Vander Sloten, Jozef; Puers, Robert; Duyck, Joke

    2007-02-01

    Tissue formation at the implant interface is known to be sensitive to mechanical stimuli. The aim of the study was to compare the bone formation around immediately loaded versus unloaded implants in two different implant macro-designs. A repeated sampling bone chamber with a central implant was installed in the tibia of 10 rabbits. Highly controlled loading experiments were designed for a cylindrical (CL) and screw-shaped (SL) implant, while the unloaded screw-shaped (SU) implant served as a control. An F-statistic model with alpha=5% determined statistical significance. A significantly higher bone area fraction was observed for SL compared with SU (pimplant contact occurred was the highest for SL and significantly different from SU (pimplant contact was observed, a loading (SL versus SU: p=0.0049) as well as an implant geometry effect (SL versus CL: p=0.01) was found, in favour of the SL condition. Well-controlled immediate implant loading accelerates tissue mineralization at the interface. Adequate bone stimulation via mechanical coupling may account for the larger bone response around the screw-type implant compared with the cylindrical implant.

  6. An economic evaluation of maxillary implant overdentures based on six vs. four implants.

    Science.gov (United States)

    Listl, Stefan; Fischer, Leonhard; Giannakopoulos, Nikolaos Nikitas

    2014-08-18

    The purpose of the present study was to assess the value for money achieved by bar-retained implant overdentures based on six implants compared with four implants as treatment alternatives for the edentulous maxilla. A Markov decision tree model was constructed and populated with parameter estimates for implant and denture failure as well as patient-centred health outcomes as available from recent literature. The decision scenario was modelled within a ten year time horizon and relied on cost reimbursement regulations of the German health care system. The cost-effectiveness threshold was identified above which the six-implant solution is preferable over the four-implant solution. Uncertainties regarding input parameters were incorporated via one-way and probabilistic sensitivity analysis based on Monte-Carlo simulation. Within a base case scenario of average treatment complexity, the cost-effectiveness threshold was identified to be 17,564 € per year of denture satisfaction gained above of which the alternative with six implants is preferable over treatment including four implants. Sensitivity analysis yielded that, depending on the specification of model input parameters such as patients' denture satisfaction, the respective cost-effectiveness threshold varies substantially. The results of the present study suggest that bar-retained maxillary overdentures based on six implants provide better patient satisfaction than bar-retained overdentures based on four implants but are considerably more expensive. Final judgements about value for money require more comprehensive clinical evidence including patient-centred health outcomes.

  7. Music enjoyment with cochlear implantation.

    Science.gov (United States)

    Prevoteau, Charlotte; Chen, Stephanie Y; Lalwani, Anil K

    2018-10-01

    Since the advent of cochlear implant (CI) surgery in the 1960s, there have been remarkable technological and surgical advances enabling excellent speech perception in quiet with many CI users able to use the telephone. However, many CI users struggle with music perception, particularly with the pitch-based and melodic elements of music. Yet remarkably, despite poor music perception, many CI users enjoy listening to music based on self-report questionnaires, and prospective studies have suggested a disassociation between music perception and enjoyment. Music enjoyment is arguably a more functional measure of one's listening experience, and thus enhancing one's listening experience is a worthy goal. Recent studies have shown that re-engineering music to reduce its complexity may enhance enjoyment in CI users and also delineate differences in musical preferences from normal hearing listeners. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. New biomaterials for orthopedic implants

    Directory of Open Access Journals (Sweden)

    Ong KL

    2015-09-01

    Full Text Available Kevin L Ong, Brian Min Yun, Joshua B WhiteExponent, Inc., Philadelphia, PA, USAAbstract: With the increasing use of orthopedic implants worldwide, there continues to be great interest in the development of novel technologies to further improve the effective clinical performance of contemporary treatment modalities and devices. Continuing research interest also exists in developing novel bulk biomaterials (eg, polycarbonate urethanes, silicon or novel formulations of existing but less widely used biomaterials (eg, polyaryletherketones, polyetheretherketone. There is also growing focus on customizing the material properties of bioabsorbables and composite materials with fillers such as bioactive ceramics. In terms of tissue engineering, more recent developments have focused on basic engineering and biological fundamentals to use cells, signaling factors, and the scaffold material itself to better restore tissue and organ structure and function. There has also been recent controversy with the use of injectables as a nonsurgical approach to treat joint disorders, but more attention is being directed toward the development of newer formulations with different molecular weights. The industry has also continuously sought to improve coatings to supplement the function of existing implants, with the goal of improving their osseointegrative qualities and incorporating antimicrobial properties. These include the use of bone morphogenetic protein, bisphosphonates, calcium phosphate, silicon nitride, and iodine. Due to the widespread use of bone graft materials, recent developments in synthetic graft materials have explored further development of bioactive glass, ceramic materials, and porous titanium particles. This review article provides an overview of ongoing efforts in the above research areas.Keywords: coatings, scaffolds, bioabsorbables, bone graft, injectables

  9. Transverse microanalysis of high energy Ion implants

    Energy Technology Data Exchange (ETDEWEB)

    Dooley, S P; Jamieson, D N; Nugent, K W; Prawer, S [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1997-12-31

    High energy ion implants in semiconductor materials have been analyzed by Channeling Contrast Microscopy (CCM) perpendicular to the implant direction, allowing imaging of the entire ion track. The damage produced by Channeled and Random 1.4 MeV H{sup +} implants into the edge of a <100> type IIa diamond wafer were analyzed by channeling into the face of the crystal. The results showed negligible damage in the surface region of the implants, and swelling induced misalignment at the end of range of the implants. Channeled 1.4 MeV H{sup +} implants in diamond had a range only 9% deeper than Random implants, which could be accounted for by dechanneling of the beam. The channeling of H{sup +}{sub 2} ions has been previously found to be identical to that of protons of half energy, however the current experiment has shown a 1% increase in {chi}{sub min} for H{sup +}{sub 2} in diamond compared to H{sup +} at 1,2 MeV per proton. This is due to repulsion between protons within the same channel. 5 refs., 2 figs.

  10. Transverse microanalysis of high energy Ion implants

    Energy Technology Data Exchange (ETDEWEB)

    Dooley, S.P.; Jamieson, D.N.; Nugent, K.W.; Prawer, S. [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1996-12-31

    High energy ion implants in semiconductor materials have been analyzed by Channeling Contrast Microscopy (CCM) perpendicular to the implant direction, allowing imaging of the entire ion track. The damage produced by Channeled and Random 1.4 MeV H{sup +} implants into the edge of a <100> type IIa diamond wafer were analyzed by channeling into the face of the crystal. The results showed negligible damage in the surface region of the implants, and swelling induced misalignment at the end of range of the implants. Channeled 1.4 MeV H{sup +} implants in diamond had a range only 9% deeper than Random implants, which could be accounted for by dechanneling of the beam. The channeling of H{sup +}{sub 2} ions has been previously found to be identical to that of protons of half energy, however the current experiment has shown a 1% increase in {chi}{sub min} for H{sup +}{sub 2} in diamond compared to H{sup +} at 1,2 MeV per proton. This is due to repulsion between protons within the same channel. 5 refs., 2 figs.

  11. Audiovisual segregation in cochlear implant users.

    Directory of Open Access Journals (Sweden)

    Simon Landry

    Full Text Available It has traditionally been assumed that cochlear implant users de facto perform atypically in audiovisual tasks. However, a recent study that combined an auditory task with visual distractors suggests that only those cochlear implant users that are not proficient at recognizing speech sounds might show abnormal audiovisual interactions. The present study aims at reinforcing this notion by investigating the audiovisual segregation abilities of cochlear implant users in a visual task with auditory distractors. Speechreading was assessed in two groups of cochlear implant users (proficient and non-proficient at sound recognition, as well as in normal controls. A visual speech recognition task (i.e. speechreading was administered either in silence or in combination with three types of auditory distractors: i noise ii reverse speech sound and iii non-altered speech sound. Cochlear implant users proficient at speech recognition performed like normal controls in all conditions, whereas non-proficient users showed significantly different audiovisual segregation patterns in both speech conditions. These results confirm that normal-like audiovisual segregation is possible in highly skilled cochlear implant users and, consequently, that proficient and non-proficient CI users cannot be lumped into a single group. This important feature must be taken into account in further studies of audiovisual interactions in cochlear implant users.

  12. Implantation doping of GaN

    International Nuclear Information System (INIS)

    Zolper, J.C.

    1996-01-01

    Ion implantation has played an enabling role in the realization of many high performance photonic and electronic devices in mature semiconductor materials systems such as Si and GaAs. This can also be expected to be the case in III-Nitride based devices as the material quality continues to improve. This paper reviews the progress in ion implantation processing of the III-Nitride materials, namely, GaN, AlN, InN and their alloys. Details are presented of the successful demonstrations of implant isolation as well as n- and p-type implantation doping of GaN. Implant doping has required activation annealing at temperatures in excess of 1,000 C. The nature of the implantation induced damage and its response to annealing is addressed using Rutherford Backscattering. Finally, results are given for the first demonstration of a GaN device fabricated using ion implantation doping, a GaN junction field effect transistor (JFET)

  13. Brainjacking: Implant Security Issues in Invasive Neuromodulation.

    Science.gov (United States)

    Pycroft, Laurie; Boccard, Sandra G; Owen, Sarah L F; Stein, John F; Fitzgerald, James J; Green, Alexander L; Aziz, Tipu Z

    2016-08-01

    The security of medical devices is critical to good patient care, especially when the devices are implanted. In light of recent developments in information security, there is reason to be concerned that medical implants are vulnerable to attack. The ability of attackers to exert malicious control over brain implants ("brainjacking") has unique challenges that we address in this review, with particular focus on deep brain stimulation implants. To illustrate the potential severity of this risk, we identify several mechanisms through which attackers could manipulate patients if unauthorized access to an implant can be achieved. These include blind attacks in which the attacker requires no patient-specific knowledge and targeted attacks that require patient-specific information. Blind attacks include cessation of stimulation, draining implant batteries, inducing tissue damage, and information theft. Targeted attacks include impairment of motor function, alteration of impulse control, modification of emotions or affect, induction of pain, and modulation of the reward system. We also discuss the limitations inherent in designing implants and the trade-offs that must be made to balance device security with battery life and practicality. We conclude that researchers, clinicians, manufacturers, and regulatory bodies should cooperate to minimize the risk posed by brainjacking. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Immunological Response to Biodegradable Magnesium Implants

    Science.gov (United States)

    Pichler, Karin; Fischerauer, Stefan; Ferlic, Peter; Martinelli, Elisabeth; Brezinsek, Hans-Peter; Uggowitzer, Peter J.; Löffler, Jörg F.; Weinberg, Annelie-Martina

    2014-04-01

    The use of biodegradable magnesium implants in pediatric trauma surgery would render surgical interventions for implant removal after tissue healing unnecessary, thereby preventing stress to the children and reducing therapy costs. In this study, we report on the immunological response to biodegradable magnesium implants—as an important aspect in evaluating biocompatibility—tested in a growing rat model. The focus of this study was to investigate the response of the innate immune system to either fast or slow degrading magnesium pins, which were implanted into the femoral bones of 5-week-old rats. The main alloying element of the fast-degrading alloy (ZX50) was Zn, while it was Y in the slow-degrading implant (WZ21). Our results demonstrate that degrading magnesium implants beneficially influence the immune system, especially in the first postoperative weeks but also during tissue healing and early bone remodeling. However, rodents with WZ21 pins showed a slightly decreased phagocytic ability during bone remodeling when the degradation rate reached its maximum. This may be due to the high release rate of the rare earth-element yttrium, which is potentially toxic. From our results we conclude that magnesium implants have a beneficial effect on the innate immune system but that there are some concerns regarding the use of yttrium-alloyed magnesium implants, especially in pediatric patients.

  15. Metal ion implantation: Conventional versus immersion

    International Nuclear Information System (INIS)

    Brown, I.G.; Anders, A.; Anders, S.; Dickinson, M.R.; MacGill, R.A.

    1994-01-01

    Vacuum-arc-produced metal plasma can be used as the ion feedstock material in an ion source for doing conventional metal ion implantation, or as the immersing plasma for doing plasma immersion ion implantation. The basic plasma production method is the same in both cases; it is simple and efficient and can be used with a wide range of metals. Vacuum arc ion sources of different kinds have been developed by the authors and others and their suitability as a metal ion implantation tool has been well established. Metal plasma immersion surface processing is an emerging tool whose characteristics and applications are the subject of present research. There are a number of differences between the two techniques, both in the procedures used and in the modified surfaces created. For example, the condensibility of metal plasma results in thin film formation and subsequent energetic implantation is thus done through the deposited layer; in the usual scenario, this recoil implantation and the intermixing it produces is a feature of metal plasma immersion but not of conventional energetic ion implantation. Metal plasma immersion is more suited (but not limited) to higher doses (>10 17 cm -2 ) and lower energies (E i < tens of keV) than the usual ranges of conventional metal ion implantation. These and other differences provide these vacuum-arc-based surface modification tools with a versatility that enhances the overall technological attractiveness of both

  16. Cochlear implant users' spectral ripple resolution.

    Science.gov (United States)

    Jeon, Eun Kyung; Turner, Christopher W; Karsten, Sue A; Henry, Belinda A; Gantz, Bruce J

    2015-10-01

    This study revisits the issue of the spectral ripple resolution abilities of cochlear implant (CI) users. The spectral ripple resolution of recently implanted CI recipients (implanted during the last 10 years) were compared to those of CI recipients implanted 15 to 20 years ago, as well as those of normal-hearing and hearing-impaired listeners from previously published data from Henry, Turner, and Behrens [J. Acoust. Soc. Am. 118, 1111-1121 (2005)]. More recently, implanted CI recipients showed significantly better spectral ripple resolution. There is no significant difference in spectral ripple resolution for these recently implanted subjects compared to hearing-impaired (acoustic) listeners. The more recently implanted CI users had significantly better pre-operative speech perception than previously reported CI users. These better pre-operative speech perception scores in CI users from the current study may be related to better performance on the spectral ripple discrimination task; however, other possible factors such as improvements in internal and external devices cannot be excluded.

  17. Mis siis juhtus Andres Lapeteusega? / Õie Orav

    Index Scriptorium Estoniae

    Orav, Õie

    2011-01-01

    Režissöör Grigori Kromanovi filmist "Mis juhtus Andres Lapeteusega?" (Tallinnfilm, 1965). Osades: Einari Koppel, Ita Ever, Heino Mandri, Kaljo Kiisk, Uno Loit, Ada Lundver jt. Lühidalt filmi kohta ilmunud arvustustest. Filmi näeb ETV2-s sarjas "Unustatud filmid"

  18. Mis seal teletornis siis tegelikult juhtus? / Avo-Rein Tereping

    Index Scriptorium Estoniae

    Tereping, Avo-Rein, 1945-

    2005-01-01

    Eesti Raadio endine tehnikadirektor kirjeldab 1991. aastal augustiputshi päevil teletornis toimunut ning rõhutab, et ei tohi unustada neid tehnilisi töötajaid, kes päästsid teletorni aparatuuri hävingust ning lõid alternatiivsed infokanalid. Ka Ilmar Raagi lavastatud Eesti Televisiooni fiktiivsest dokumentaaldraamast "August 1991"

  19. Kui vajad lojaalsust, siis võta koer! / Hando Sinisalu

    Index Scriptorium Estoniae

    Sinisalu, Hando, 1970-

    2008-01-01

    Briti kaubanduskontserni Tesco kliendilojaalsusprogrammist. Lisa: Lojaalsusprogrammi juhtimismudel; Eduka kliendiprogrammi kuus kriteeriumi. Vt. samas: Tarmo Hõbe. Me ei müü üksikuid tooteid, vaid elustiili ja emotsioone

  20. EKKM, mis siis valesti on? : noor kunst / Anneli Porri

    Index Scriptorium Estoniae

    Porri, Anneli, 1980-

    2007-01-01

    Eesti Kaasaegse Kunsti Muuseumis lõppenud näitusest "Midagi on valesti", kus esinesid Eesti Kunstiakadeemia fotograafia eriala III kursuse tudengid. Kuraator Marco Laimre. Eesti Kaasaegse Kunsti Muuseumis 8. VIII toimunud ümarlauast "Mida teha?"

  1. Millist presidenti siis vajab Eesti vabariik? / Ando Leps

    Index Scriptorium Estoniae

    Leps, Ando, 1935-

    2001-01-01

    Autor analüüsib viit presidendikandidaati: Peeter Kreitzbergi, Arnold Rüütlit, Toomas Savi, Andres Tarandit ja Peeter Tulvistet. President Lennart Meri kriitika. Järgneb: Kesknädal, 24. juuli 2001, lk. 7; 1. aug. 2001, lk. 7; 8. aug. 2001, lk. 7; 15. aug. 2001, lk. 7; 22. aug. 2001, lk. 7. Ilmunud ka: Virumaa Teataja, 31. juuli 2001, lk. 7; 7. aug. 2001, lk. 7; 15. aug. 2001, lk. 7; 23. aug. 2001, lk. 7

  2. Kui kapital veab alt, siis turvaliselt / Aleksander Tsapov

    Index Scriptorium Estoniae

    Tsapov, Aleksander

    2006-01-01

    Kuraatorinäitus "Kapital (see veab meid alt)" Tallinna Kunstihoones. Kuraator Simon Sheikh. Fia-Stina Sandlundi, Katya Sanderi, Oliver Ressleri, Ashley Hunti ja Susan Kelly&Stephen Mortoni töödest näitusel

  3. Kui parimast ei piisa, siis piisab erinevast / Gustav Hafren

    Index Scriptorium Estoniae

    Hafren, Gustav

    2003-01-01

    Autor leiab, et turul, kus ei võida mitte kvaliteetsemad tooted, vaid tooted, mis omavad kindlat kohta klientide teadvuses, on kõige olulisem eristuda konkurentidest. Lisa: Milline on kliendi teadvus? Kokkuvõte autori ettekandest turunduskonverentsil "Password 2003".

  4. Millist presidenti siis vajab Eesti vabariik? / Ando Leps

    Index Scriptorium Estoniae

    Leps, Ando, 1935-

    2001-01-01

    Järg Kesknädal Jul/24, Aug/1;8;15;22 lk. 7. Ilmunud ka Virumaa Teataja Jul/31 lk. 7; Aug/7;15;23 lk. 7. Autor analüüsib viit presidendikandidaati: Peeter Kreitzbergi, Arnold Rüütlit, Toomas Savi, Andres Tarandit ja Peeter Tulvistet. President Lennart Meri kriitika

  5. Kus ta siis ometi on - see Bob Dylan? / Immo Mihkelson

    Index Scriptorium Estoniae

    Mihkelson, Immo, 1959-

    2008-01-01

    Todd Haynes'i mängufilm muusik Bob Dylanist "Kus on Bob Dylan?" ("I'm Not There") : laulja alter ego kehastavad Ben Whishaw, Christian Bale, Heath Ledger, Cate Blanchett, Richard Gere, Marcus Carl Franklin : Ameerika Ühendriigid 2007. 4. juunil Saku Suurhallis toimuvast kontserdist. Jaak Johanson, Tõnis Mägi, Riho Sibul, Hannes Varblane ameerika lauljast

  6. Kui Kerry saab USA presidendiks, siis... / Anvar Samost

    Index Scriptorium Estoniae

    Samost, Anvar, 1971-

    2004-01-01

    Autor võrdleb USA presidendi George W. Bushi ja presidendikandidaat John Kerry välispoliitilisi seisukohti ning leiab, et peaaegu kõigis välispoliitika küsimustes on nad ühel meelel ja mõnes küsimuses on Kerry vaated pigem radikaalsemad

  7. Tase '08 - kui tase siis ikkagi? / Maarin Ektermann

    Index Scriptorium Estoniae

    Ektermann, Maarin

    2008-01-01

    Eesti Kunstiakadeemia lõputööde näitustest, mis toimuvad festivali "Tase '08" raames: vabade kunstide teaduskonna magistritööde väljapanekust Kumu Kunstimuuseumis; disainiteaduskonna lõputööde, mis valmisid koostöös IT Kolledzhi üliõpilastega, näitusest "Arukalt" "SooSoo" galeriis

  8. A prospective, split-mouth study comparing tilted implants with angulated connection versus conventional implants with angulated abutment.

    Science.gov (United States)

    Van Weehaeghe, Manú; De Bruyn, Hugo; Vandeweghe, Stefan

    2017-12-01

    An angulation of the implant connection could overcome the problems related to angulated abutments. This study compares conventional implants with angulated abutment to tilted implants with an angulated connection. Twenty patients were treated in the edentulous mandible. In the posterior jaw locations, one conventional tilted implant with angulated abutment and one angulated implant without abutment were placed. In the anterior jaw, two conventional implants were placed, one with and one without abutment. Implants were immediately loaded and 3 months later, the final bridge (PFM or monolithic zirconia) was placed. After a follow-up of 48 months, 17 patients were available for clinical examination. The mean overall marginal bone loss (MBL) was 1.26 mm. No significant differences in implant survival, MBL, periodontal indices, patients' satisfaction, or complications was found between implants restored on abutment or implant level, between the posteriorly located angulated implant nor angulated abutment, and between both anterior implants with or without abutment. The posterior implants demonstrated less MBL compared to the anterior implants (P abutment were replaced and four loose bridge screws connected to the angulated abutments had to be tightened. Patients were overall satisfied (4.74/5). An implant with angulated connection may results in a stronger connection but does not affect the marginal bone loss. No difference in MBL was seen between implants restored on abutment or implant level. Zirconia seems to reduce the amount of plaque. © 2017 Wiley Periodicals, Inc.

  9. Analysis of 30 breast implant rupture cases.

    Science.gov (United States)

    Tark, Kwan Chul; Jeong, Hii Sun; Roh, Tae Suk; Choi, Jong Woo

    2005-01-01

    Breast implants used for augmentation mammoplasty or breast reconstruction could rupture from various causes such as trauma or spontaneous failure. The objectives of this study were to investigate the relationships between the causes of implant rupture and the degree of capsular contracture, and then to evaluate the relative efficacies of specific signs on magnetic resonance imaging (MRI) known to be beneficial for diagnosing the rupture. A retrospective review identified patients with prosthetic implant rupture or impending rupture treated by the senior author. The 30 cases of implant rupture available for review were classified into two groups: intracapsular and extracapsular ruptures. The 30 cases of breast implant ruptures were analyzed with respect to the clinical symptoms and signs, the causes of rupture, the degree of capsular contracture, and therapeutic plans. Among the 30 cases, 14 patients who had undergone MRI during the diagnostic period were analyzed with respect to the relationships between MRI readings and operative findings. Spontaneous rupture of membranes was most common (80%), followed by failure because of trauma (7%) and valve or implant base (4%). The symptoms during implant rupture were contour deformity, palpated mass-like lesions, pain, and focal inflammation. According to the analysis of specific MRI signs, the sensitivity and specificity of the linguine sign were 87% and 100%, respectively, for intracapsular rupture. For extracapsular rupture, the sensitivity and specificity of the linguine sign were, respectively, 67% and 75%. The sensitivity and specificity of the rat-tail sign and tear drop sign were 14% and 50%, respectively. Breast implant rupture was correlated with the degree of capsular contracture in our study. Among the various specific MRI signs used in diagnosing the rupture, the linguine sign was reliable and had a high sensitivity and specificity, especially in cases of intracapsular rupture. On the other hand, the rat

  10. Implant Mandibular Overdentures Retained by Immediately Loaded Implants: A 1-Year Randomized Trial Comparing the Clinical and Radiographic Outcomes Between Mini Dental Implants and Standard-Sized Implants.

    Science.gov (United States)

    Zygogiannis, Kostas; Aartman, Irene Ha; Parsa, Azin; Tahmaseb, Ali; Wismeijer, Daniel

    The aim of this 1-year randomized trial was to evaluate and compare the clinical and radiographic performance of four immediately loaded mini dental implants (MDIs) and two immediately loaded standard-sized tissue-level (STL) implants, placed in the interforaminal region of the mandible and used to retain mandibular overdentures (IODs) in completely edentulous patients. A total of 50 completely edentulous patients wearing conventional maxillary dentures and complaining about insufficient retention of their mandibular dentures were divided into two groups; 25 patients received four MDIs and 25 patients received two STL implants. The marginal bone loss (MBL) at the mesial and distal sides of each implant was assessed by means of standardized intraoral radiographs after a period of 1 year. Implant success and survival rates were also calculated. Immediate loading was possible for all patients in the first group. In the second group, an immediate loading protocol could not be applied for 10 patients. These patients were treated with a delayed loading protocol. A mean MBL of 0.42 ± 0.56 mm for the MDIs and 0.54 ± 0.49 mm for the immediately loaded STL implants was recorded at the end of the evaluation period. There was no statistically significant difference between the MDIs and the immediately loaded STL implants. Two MDIs failed, resulting in a survival rate of 98%. The success rate was 91%. For the immediately loaded conventional implants, the survival rate was 100% and the success rate 96.7% after 1 year of function. However, in 10 patients, the immediate loading protocol could not be followed. Considering the limitations of this short-term clinical study, immediate loading of four unsplinted MDIs or two splinted STL implants to retain mandibular overdentures seems to be a feasible treatment option. The marginal bone level changes around the MDIs were well within the clinically acceptable range.

  11. Prevalence of Peri-Implant Mucositis and Peri-Implantitis in Patients Treated with a Combination of Axial and Tilted Implants Supporting a Complete Fixed Denture

    Directory of Open Access Journals (Sweden)

    Nicolò Cavalli

    2015-01-01

    Full Text Available Objectives. The aim of this retrospective study was to assess the incidence and prevalence of peri-implant mucositis and peri-implantitis in patients with a fixed full-arch prosthesis supported by two axial and two tilted implants. Materials and Methods. Sixty-nine patients were included in the study. Each patient received a fixed full-arch prosthesis supported by two mesial axial and two distal tilted implants to rehabilitate the upper arch, the lower arch, or both. Three hundred thirty-six implants for 84 restorations were delivered. Patients were scheduled for follow-up visits every 6 months in the first 2 years and yearly after. At each follow-up visit peri-implant mucositis and peri-implantitis were diagnosed if present. Results. The overall follow-up range was from 12 to 130 months (mean 63,2 months. Three patients presented peri-implantitis. The prevalence of peri-implant mucositis ranged between 0 and 7,14% of patients (5,06% of implants while the prevalence of peri-implantitis varied from 0 to 4,55% of patients (3,81% of implants. Conclusions. The prevalence and incidence of peri-implant mucositis and peri-implantitis are lower than most of the studies in literature. Therefore this kind of rehabilitation could be considered a feasible option, on the condition of adopting a systematic hygienic protocol.

  12. The diagnosis of breast implant rupture

    DEFF Research Database (Denmark)

    Hölmich, Lisbet R; Vejborg, Ilse; Conrad, Carsten

    2005-01-01

    participated in either one or two study MRI examinations, aiming at determining the prevalence and incidence of silent implant rupture, respectively, and who subsequently underwent explantation. Implant rupture status was determined by four independent readers and a consensus diagnosis of either rupture...... were in fact ruptured at surgery. Thirty-four of the 43 intact implants were described as intact at surgery. When categorising possible ruptures as ruptures, there were one false positive and nine false negative rupture diagnoses at MRI yielding an accuracy of 92%, a sensitivity of 89...

  13. Implant rehabilitation of partial maxillectomy edentulous patien

    Directory of Open Access Journals (Sweden)

    Mahesh E Gowda

    2013-01-01

    Full Text Available Edentulous patients with maxillectomy defects present a significant challenge for prosthetic rehabilitation and the adaptive capabilities of the patient as retention is highly compromised. Hence, the option of using endosseous implants to increase obturator retention has been used. A patient of mucormycosis of the left maxilla was treated with surgical excision. After satisfactory healing, definitive implant supported magnet retained prosthesis was fabricated for the patient. Implants with magnetic units offer a practical method of improving the retention of obturators provided acceptable prosthetic protocols are followed for the rehabilitation.

  14. Implant rehabilitation of partial maxillectomy edentulous patient

    Science.gov (United States)

    Gowda, Mahesh E.; Mohan, Murali S.; Verma, Kamal; Roy, I. D.

    2013-01-01

    Edentulous patients with maxillectomy defects present a significant challenge for prosthetic rehabilitation and the adaptive capabilities of the patient as retention is highly compromised. Hence, the option of using endosseous implants to increase obturator retention has been used. A patient of mucormycosis of the left maxilla was treated with surgical excision. After satisfactory healing, definitive implant supported magnet retained prosthesis was fabricated for the patient. Implants with magnetic units offer a practical method of improving the retention of obturators provided acceptable prosthetic protocols are followed for the rehabilitation. PMID:24124314

  15. Miragel implant, apropos of 3 cases

    OpenAIRE

    Rodríguez Rodríguez, Beatriz; García Ferrer, Laine; Cheong Quiala, Mayelin; Gallar Gutiérrez, Yolescy; Pozo Correa, Susel

    2013-01-01

    Se exponen las consecuencias a largo plazo del uso del implante de miragel como tratamiento del desprendimiento de retina. Se presentan las características durante la cirugía y el postoperatorio de la explantación de este tipo de implante en 3 pacientes que acudieron a la consulta de Retina del Hospital Oftalmológico «Amistad Argelia Cuba» en Djelfa, Republica Popular y Democrática de Argelia, con el diagnóstico de cirugía convencional de retina con implante de miragel realizado en Francia en...

  16. High-fluence implantation in insulators. 1

    International Nuclear Information System (INIS)

    Mazzoldi, P.

    1989-01-01

    The defects which can be formed by ion implantation depend upon the insulator structure and composition. Thus, for glasses and ceramics, different changes are expected in mechanical and tribological properties, network dilatation, induced optical absorption and luminescence, compositional changes and modifications in the chemical behaviour. The modifications induced by ion implantation in the composition of glasses, with particular reference to alkali silicate glasses, the mechanical and tribological properties of ion implanted insulators, in particular glasses and ceramics, and the optical properties are discussed. 56 refs.; 20 figs

  17. Mini-implant-supported Molar Distalization

    Directory of Open Access Journals (Sweden)

    Amit Goyal

    2012-01-01

    Full Text Available Temporary anchorage devices popularly called mini-implants or miniscrews are the latest addition to an orthodontist′s armamentarium. The following case report describes the treatment of a 16-year-old girl with a pleasant profile, moderate crowding and Angle′s Class II molar relationship. Maxillary molar distalization was planned and mini-implants were used to preserve the anterior anchorage. After 13 months of treatment, Class I molar and canine relation was achieved bilaterally and there was no anterior proclination. Thus, mini-implants provide a viable option to the clinician to carry out difficult tooth movements without any side effects.

  18. Ion implantation in semiconductors and other materials

    International Nuclear Information System (INIS)

    Guernet, G.; Bruel, M.; Gailliard, J.P.; Garcia, M.; Robic, J.Y.

    1977-01-01

    The evolution of ion implantation techniques in the field of semiconductors and its extension to various fields such as metallurgy, mechanics, superconductivity and opto-electronics are considered. As for semiconductors ion implantation is evoked as: a means of predeposition of impurities at low doping level (10 11 to 10 14 cm -2 ); a means for obtaining profiles of controlled concentration; a means of reaching high doping levels with using 'strong current' implantation machines of the second generation. Some results obtained are presented [fr

  19. Radiographic examination for successful dental implant

    International Nuclear Information System (INIS)

    Lee, Sam Sun; Choi, Soon Chul

    2005-01-01

    Recently implant has become an important field in dental clinic. Radiographic examination of pre- and post-operation is essential for successful treatment. Clinicians should have knowledge about the purpose of the radiographic examination, suitable imaging modality for the cases, anatomic landmarks of tooth and jaw bone, advantage and limitation of panoramic radiographic examination for implant, principle and interpretation of cross-sectional imaging, bone mineral density, post-operative radiographic examination. This paper will be helpful to get above information for dentists who want to do dental implant successfully.

  20. Fabrication of implanted $^{22}$Na targets

    CERN Multimedia

    2002-01-01

    A knowledge of the $^{22}$Na(p,$\\gamma$)$^{23}$ Mg reaction rate is of significant astrophysical interest. In order to complete previous studies of this reaction, radioactive $^{22}$Na targets of high purity are required. We ask for support to fabricate these targets via the implantation technique at ISOLDE GPS (off—line mode) using $^{22}$Na nuclides in an Al matrix produced in Nov. 1990 at the PSI (Zürich). The $^{22}$Na nuclides are released and ionized in a surface ionisation source, mass-analyzed at ISOLDE GPS, and implanted in a Ni-Ta backing and a C—foil in a special implantation setup.

  1. Ion implantation methods for semiconductor substrates

    International Nuclear Information System (INIS)

    Matsushita, T.; Mamine, T.; Hayashi, H.; Nishiyama, K.

    1980-01-01

    A method of ion implantation for controlling the life time of minority carriers in a semiconductor substrate and hence to reduce the temperature dependency of the life time, comprises implanting iron ions into an N type semiconductor substrate with a dosage of 10 10 to 10 15 ions cm -2 , and then heat-treating the implanted substrate at 850 0 to 1250 0 C. The method is applicable to the production of diodes, transistors, Si controlled rectifiers and gate controlled switching devices. (author)

  2. Implanted Antennas in Medical Wireless Communications

    CERN Document Server

    Rahmat-Samii, Yahya; Balanis, Constantine

    2006-01-01

    Implanted Antennas in Medical Wireless Communications summarizes the results of recent research activities on the subject of implanted antennas for medical wireless communication systems. It is anticipated that in the near future sophisticated medical devices will be implanted inside the human body for medical telemetry and telemedicine. To establish effective and efficient wireless links with these devices, it is pivotal to give special attention to antenna designs that are low profile, small, safe, and cost effective. In this book, authors Yahya Rahmat-Samii and Jaehoon Kim demonstrate how a

  3. Physical state of implanted W in copper

    International Nuclear Information System (INIS)

    Borders, J.A.; Cullis, A.G.; Poate, J.M.

    1975-01-01

    Transmission electron microscopy and 4 He ion channeling measurements were combined to investigate the physical state of implanted W in copper. For 60 0 K implantations of 2 x 10 15 W cm -2 , W is found to be 100 percent substitutional and is still 90 percent substitutional for a dose of 10 16 W cm -2 . Implantation of 10 17 W cm -2 produces a thin disordered surface layer of W and Cu with the W occupying no regular lattice site. On annealing to 600 0 C, W precipitates are formed with dimensions of a few hundred A and certain preferred orientations in the Cu lattice. (auth)

  4. Particle migration and gap healing around trabecular metal implants

    DEFF Research Database (Denmark)

    Rahbek, O; Kold, S; Zippor, Berit

    2005-01-01

    Bone on-growth and peri-implant migration of polyethylene particles were studied in an experimental setting using trabecular metal and solid metal implants. Cylindrical implants of trabecular tantalum metal and solid titanium alloy implants with a glass bead blasted surface were inserted either i...

  5. Osteoporotic rat models for evaluation of osseointegration of bone implants

    NARCIS (Netherlands)

    Alghamdi, H.S.A.; Beucken, J.J.J.P van den; Jansen, J.A.

    2014-01-01

    Osseointegration of dental and orthopedic bone implants is the important process that leads to mechanical fixation of implants and warrants implant functionality. In view of increasing numbers of osteoporotic patients, bone implant surface optimization strategies with instructive and drug-loading

  6. Mandibular implant-supported overdentures: attachment systems, and number and locations of implants--Part I.

    Science.gov (United States)

    Warreth, Abdulhadi; Alkadhimi, Aslam Fadel; Sultan, Ahmed; Byrne, Caroline; Woods, Edel

    2015-01-01

    The use of dental implants in replacing missing teeth is an integral part of restorative dental treatment. Use of conventional complete dentures is associated with several problems such as lack of denture stability, support and retention. However, when mandibular complete dentures were used with two or more implants, an improvement in the patients' psychological and social well-being could be seen. There is general consensus that removable implant-supported overdentures (RISOs) with two implants should be considered as the first-choice standard of care for an edentulous mandible. This treatment option necessitates the use of attachment systems that connect the complete denture to the implant. Nevertheless, each attachment system has its inherent advantages and disadvantages, which should be considered when choosing a system. The first part of this article provides an overview on options available to restore the mandibular edentulous arch with dental implants. Different types of attachment systems, their features and drawbacks are also reviewed.

  7. Implantation of β-emitters on biomedical implants: 32 P isotropic ion implantation using a coaxial plasma reactor

    International Nuclear Information System (INIS)

    Fortin, M.A.; Paynter, R.W.; Sarkissian, A.; Stansfield, B.L.; Terreault, B.; Dufresne, V.

    2003-01-01

    The development of endovascular brachytherapy and the treatment of certain types of cancers (liver, lung, prostate) often require the use of beta-emitters, sometimes in the form of radioisotope-implanted devices. Among the most commonly used isotopes figures 32 P, a pure beta-emitter (maximum energy: 1.7 MeV), of which the path in biological tissues is of a few cm, restricting the impact of electron bombardment to the immediate environment of the implant. Several techniques and processes have been tried to elaborate surfaces and devices showing strongly bonded, or implanted 32 P. Anodizing, vapor phase deposition, grafting of oligonucleotides, as well as ion implantation processes have been investigated by several research groups as methods to implant beta-radioisotopes into surfaces. A coaxial plasma reactor was developed at INRS to implant radioisotopes into cylindrical metallic objects, such as coronary stents commonly used in angioplasty procedures. The dispersion of 32 P atoms on the interior surfaces of the chamber can be investigated using radiographs, contributing to image the plasma ion transport mechanisms that guide the efficiency of the implantation procedure. The amount of radioactivity on the wall liner, on the internal components, and on the biomedical implants are quantified using a surface barrier detector. A comparative study establishes a relationship between the gray scale of the radiographs, and dose measurements. A program was developed to convert the digitized images into maps showing surface dose density in mCi/cm 2 . An integration process allows the quantification of the doses on the walls and components of the reactor. Finally, the resulting integral of the 32 P dose is correlated to the initial amount of radioactivity inserted inside the implanter before the dismantling procedure. This method could be introduced as a fast and reliable way to test, qualify and assess the amount of radioactivity present on the as-produced implants

  8. PEEK with Reinforced Materials and Modifications for Dental Implant Applications

    Directory of Open Access Journals (Sweden)

    Fitria Rahmitasari

    2017-12-01

    Full Text Available Polyetheretherketone (PEEK is a semi-crystalline linear polycyclic thermoplastic that has been proposed as a substitute for metals in biomaterials. PEEK can also be applied to dental implant materials as a superstructure, implant abutment, or implant body. This article summarizes the current research on PEEK applications in dental implants, especially for the improvement of PEEK surface and body modifications. Although various benchmark reports on the reinforcement and surface modifications of PEEK are available, few clinical trials using PEEK for dental implant bodies have been published. Controlled clinical trials, especially for the use of PEEK in implant abutment and implant bodies, are necessary.

  9. Location of unaccessible implant surface areas during debridement in simulated peri-implantitis therapy

    OpenAIRE

    Steiger-Ronay, Valerie; Merlini, Andrea; Wiedemeier, Daniel B.; Schmidlin, Patrick R.; Attin, Thomas; Sahrmann, Philipp

    2017-01-01

    Background An in vitro model for peri-implantitis treatment was used to identify areas that are clinically difficult to clean by analyzing the pattern of residual stain after debridement with commonly employed instruments. Methods Original data from two previous publications, which simulated surgical (SA) and non-surgical (NSA) implant debridement on two different implant systems respectively, were reanalyzed regarding the localization pattern of residual stains after instrumentation. Two bli...

  10. Chimeric Peptides as Implant Functionalization Agents for Titanium Alloy Implants with Antimicrobial Properties

    Science.gov (United States)

    Yucesoy, Deniz T.; Hnilova, Marketa; Boone, Kyle; Arnold, Paul M.; Snead, Malcolm L.; Tamerler, Candan

    2015-04-01

    Implant-associated infections can have severe effects on the longevity of implant devices and they also represent a major cause of implant failures. Treating these infections associated with implants by antibiotics is not always an effective strategy due to poor penetration rates of antibiotics into biofilms. Additionally, emerging antibiotic resistance poses serious concerns. There is an urge to develop effective antibacterial surfaces that prevent bacterial adhesion and proliferation. A novel class of bacterial therapeutic agents, known as antimicrobial peptides (AMPs), are receiving increasing attention as an unconventional option to treat septic infection, partly due to their capacity to stimulate innate immune responses and for the difficulty of microorganisms to develop resistance towards them. While host and bacterial cells compete in determining the ultimate fate of the implant, functionalization of implant surfaces with AMPs can shift the balance and prevent implant infections. In the present study, we developed a novel chimeric peptide to functionalize the implant material surface. The chimeric peptide simultaneously presents two functionalities, with one domain binding to a titanium alloy implant surface through a titanium-binding domain while the other domain displays an antimicrobial property. This approach gains strength through control over the bio-material interfaces, a property built upon molecular recognition and self-assembly through a titanium alloy binding domain in the chimeric peptide. The efficiency of chimeric peptide both in-solution and absorbed onto titanium alloy surface was evaluated in vitro against three common human host infectious bacteria, Streptococcus mutans, Staphylococcus epidermidis, and Escherichia coli. In biological interactions such as occur on implants, it is the surface and the interface that dictate the ultimate outcome. Controlling the implant surface by creating an interface composed chimeric peptides may therefore

  11. A survey of cardiac implantable electronic device implantation in India: By Indian Society of Electrocardiology and Indian Heart Rhythm Society

    Directory of Open Access Journals (Sweden)

    Jayaprakash Shenthar

    2016-01-01

    Conclusion: A large proportion of CIED implants in India are PM for bradyarrhythmic indications, predominantly AV block. ICD's are implanted almost equally for primary and secondary prophylaxis. Most CRT devices are implanted for NYHA Class III. There is a male predominance for implantation of CIED.

  12. The effects of implant surface roughness and surgical technique on implant fixation in an in vitro model.

    NARCIS (Netherlands)

    Shalabi, M.M.; Wolke, J.G.C.; Jansen, J.A.

    2006-01-01

    OBJECTIVES: The aim of the present study was to determine the relationship between implant surface parameters, surgical approach and initial implant fixation. MATERIAL AND METHODS: Sixty tapered, conical, screw-shaped implants with machined or etched surface topography were implanted into the

  13. Biodegradable radioactive implants for glaucoma filtering surgery produced by ion implantation

    Energy Technology Data Exchange (ETDEWEB)

    Assmann, W. [Department fuer Physik, Ludwig-Maximilians-Universitaet Muenchen, 85748 Garching (Germany)]. E-mail: walter.assmann@lmu.de; Schubert, M. [Department fuer Physik, Ludwig-Maximilians-Universitaet Muenchen, 85748 Garching (Germany); Held, A. [Augenklinik, Technische Universitaet Muenchen, 81675 Munich (Germany); Pichler, A. [Augenklinik, Technische Universitaet Muenchen, 81675 Muenchen (Germany); Chill, A. [Zentralinstitut fuer Medizintechnik, Technische Universitaet Muenchen, 85748 Garching (Germany); Kiermaier, S. [Zentralinstitut fuer Medizintechnik, Technische Universitaet Muenchen, 85748 Garching (Germany); Schloesser, K. [Forschungszentrum Karlsruhe, 76021 Karlsruhe (Germany); Busch, H. [NTTF GmbH, 53619 Rheinbreitbach (Germany); Schenk, K. [NTTF GmbH, 53619 Rheinbreitbach (Germany); Streufert, D. [Acri.Tec GmbH, 16761 Hennigsdorf (Germany); Lanzl, I. [Augenklinik, Technische Universitaet Muenchen, 81675 Munich (Germany)

    2007-04-15

    A biodegradable, {beta}-emitting implant has been developed and successfully tested which prevents fresh intraocular pressure increase after glaucoma filtering surgery. Ion implantation has been used to load the polymeric implants with the {beta}-emitter {sup 32}P. The influence of ion implantation and gamma sterilisation on degradation and {sup 32}P-fixation behavior has been studied by ion beam and chemical analysis. Irradiation effects due to the applied ion fluence (10{sup 15} ions/cm{sup 2}) and gamma dose (25 kGy) are found to be tolerable.

  14. Expressive Language Development in 45 Cochlear Implanted Children Following 2 Years of Implantation

    Directory of Open Access Journals (Sweden)

    Seyed Basir Hashemi

    2011-10-01

    Full Text Available Objectives: Profound hearing loss encounters children with delay in speech and language. As it is known language acquisition in young deaf children is a lengthy process, but cochlear implanted children have better spoken language skills than if they had not received the device. According to the importance of cochlear implant in deaf child's language development, this study evaluates the effect of different variables on child's language performance. Methods: 45 cochlear implanted children were tested, all of whom had used the device for at least 2 years. In order to evaluate the children, the NEWSHA test which is fitted for Persian speaking children was performed and language development of the children was compared through stepwise discriminant analysis. Results: After evaluation of the effect of different variables like child's age of implantation, participating in rehabilitation classes, parent's cooperation and their level of education, we came to a conclusion that the child's age of implantation and rehabilitation program significantly develop the child's language performance. Discussion: The value of cochlear implant in improvement of deaf children in speech, language perception, production and comprehension is confirmed by different studies which have been done on cochlear implanted children. Also, the present study indicates that language development in cochlear implanted children is highly related to their age of implantation and rehabilitation program.

  15. Bone-Implant Contact around Crestal and Subcrestal Dental Implants Submitted to Immediate and Conventional Loading

    Directory of Open Access Journals (Sweden)

    Ana Emília Farias Pontes

    2014-01-01

    Full Text Available The present study aims to evaluate the influence of apicocoronal position and immediate and conventional loading in the percentage of bone-implant contact (BIC. Thus, 36 implants were inserted in the edentulous mandible from six dogs. Three implants were installed in each hemimandible, in different positions in relation to the ridge: Bone Level (at crestal bone level, Minus 1 (one millimeter apical to crestal bone, and Minus 2 (two millimeters apical to crestal bone. In addition, each hemimandible was submitted to a loading protocol: immediate (prosthesis installed 24 hours after implantation or conventional (prosthesis installed 120 days after implantation. Ninety days after, animals were killed, and implant and adjacent tissues were prepared for histometric analysis. BIC values from immediate loaded implants were 58.7%, 57.7%, and 51.1%, respectively, while conventional loaded implants were 61.8%, 53.8%, and 68.4%. Differences statistically significant were not observed among groups (P=0.10, ANOVA test. These findings suggest that different apicocoronal positioning and loading protocols evaluated did not interfere in the percentage of bone-implant contact, suggesting that these procedures did not jeopardize osseointegration.

  16. Plasma-implantation-based surface modification of metals with single-implantation mode

    Science.gov (United States)

    Tian, X. B.; Cui, J. T.; Yang, S. Q.; Fu, Ricky K. Y.; Chu, Paul K.

    2004-12-01

    Plasma ion implantation has proven to be an effective surface modification technique. Its biggest advantage is the capability to treat the objects with irregular shapes without complex manipulation of target holder. Many metal materials such as aluminum, stainless steel, tool steel, titanium, magnesium etc, has been treated using this technique to improve their wear-resistance, corrosion-resistance, fatigue-resistance, oxidation-resistance, bio-compatiblity etc. However in order to achieve thicker modified layers, hybrid processes combining plasma ion implantation with other techniques have been frequently employed. In this paper plasma implantation based surface modification of metals using single-implantation mode is reviewed.

  17. The team approach to managing dental implant complications: strategies for treating peri-implantitis.

    Science.gov (United States)

    Rosen, Paul S

    2013-10-01

    Practitioners who are knowledgeable about the risk factors identified by the Consensus Report of the Sixth European Workshop on Periodontology and who are trained in techniques to eliminate or reduce them may be able to significantly improve long-term implant outcomes. A careful review of the literature suggests that this will include treatment planning, restoring a patient to periodontal heath before initiating care, appropriate implant selection, complete cement removal, and diligent recordkeeping that will track changes and enable early intervention should complications arise. In the case of the biologic complication of peri-implantitis, recent reports suggest that regenerative care may restore implants back to health.

  18. Impact of implant design on primary stability of orthodontic mini-implants.

    Science.gov (United States)

    Wilmes, Benedict; Ottenstreuer, Stephanie; Su, Yu-Yu; Drescher, Dieter

    2008-01-01

    Skeletal anchorage with mini-implants has greatly broadened the treatment possibilities in orthodontics over the last few years. To reduce implant failure rates, it is advisable to obtain adequate primary stability. The aim of this study was to quantitatively analyze the impact of implant design and dimension on primary stability. Forty-two porcine iliac bone segments were prepared and embedded in resin. To evaluate the primary stability, we documented insertion torques of the following mini-implants: Aarhus Screw, AbsoAnchor, LOMAS, Micro-Anchorage-System, ORLUS and Spider Screw. In each bone, five Dual Top Screws were inserted for reference purposes to achieve comparability among the specimens. We observed wide variation in insertion torques and hence primary stability, depending on mini-implant design and dimension; the great impact that mini-implant diameter has on insertion torques was particularly conspicuous. Conical mini-implants achieved higher primary stabilities than cylindrical designs. The diameter and design of the mini-implant thread have a distinctive impact on primary stability. Depending on the region of insertion and local bone quality, the choice of the mini-implant design and size is crucial to establish sufficient primary stability.

  19. Micro-cutting of silicon implanted with hydrogen and post-implantation thermal treatment

    Science.gov (United States)

    Jelenković, Emil V.; To, Suet; Sundaravel, B.; Xiao, Gaobo; Huang, Hu

    2016-07-01

    It was reported that non-amorphizing implantation by hydrogen has a potential in improving silicon machining. Post-implantation high-temperature treatment will affect implantation-induced damage, which can have impact on silicon machining. In this article, a relation of a thermal annealing of hydrogen implanted in silicon to micro-cutting experiment is investigated. Hydrogen ions were implanted into 4″ silicon wafers with 175 keV, 150 keV, 125 keV and doses of 2 × 1016 cm-2, 2 × 1016 cm-2 and 3 × 1016 cm-2, respectively. In this way, low hydrogen atom-low defect concentration was created in the region less than ~0.8 μm deep and high hydrogen atom-high defect concentration was obtained at silicon depth of ~0.8-1.5 μm. The post-implantation annealing was carried out at 300 and 400 °C in nitrogen for 1 h. Physical and electrical properties of implanted and annealed samples were characterized by secondary ion mass spectroscopy (SIMS), X-ray diffraction (XRD), Rutherford backscattering (RBS) and nanoindentation. Plunge cutting experiment was carried out in and silicon crystal direction. The critical depth of cut and cutting force were monitored and found to be influenced by the annealing. The limits of hydrogen implantation annealing contribution to the cutting characteristics of silicon are discussed in light of implantation process and redistribution of hydrogen and defects generation during annealing process.

  20. Wear mechanisms in ceramic hip implants.

    Science.gov (United States)

    Slonaker, Matthew; Goswami, Tarun

    2004-01-01

    The wear in hip implants is one of the main causes for premature hip replacements. The wear affects the potential life of the prosthesis and subsequent removals of in vivo implants. Therefore, the objective of this article is to review various joints that show lower wear rates and consequently higher life. Ceramics are used in hip implants and have been found to produce lower wear rates. This article discusses the advantages and disadvantages of ceramics compared to other implant materials. Different types of ceramics that are being used are reviewed in terms of the wear characteristics, debris released, and their size together with other biological factors. In general, the wear rates in ceramics were lower than that of metal-on-metal and metal-on-polyethylene combinations.

  1. Endocardial Pacemaker Implantation in Neonates and Infants

    Directory of Open Access Journals (Sweden)

    Canan Ayabakan

    2006-04-01

    Full Text Available Transvenous pacemaker lead implantation is the preferred method of pacing in adult patients. Lead performance and longevity are superior and the implantation approach can be performed under local anaesthetic with a very low morbidity. In children, and especially in neonates and infants, the epicardial route was traditionally chosen until the advent of smaller generators and lead implantation techniques that allowed growth of the child without lead displacement. Endocardial implantation is not universally accepted, however, as there is an incidence of venous occlusion of the smaller veins of neonates and infants with concerns for loss of venous access in the future. Growing experience with lower profile leads, however, reveals that endocardial pacing too can be performed with low morbidity and good long-term results in neonates and infants.

  2. Semiconductor applications of plasma immersion ion implantation ...

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science; Volume 25; Issue 6. Semiconductor applications of plasma immersion ion implantation technology ... Department of Electronic Science, Kurukshetra University, Kurukshetra 136 119, India ...

  3. Quality standards for bone conduction implants.

    Science.gov (United States)

    Gavilan, Javier; Adunka, Oliver; Agrawal, Sumit; Atlas, Marcus; Baumgartner, Wolf-Dieter; Brill, Stefan; Bruce, Iain; Buchman, Craig; Caversaccio, Marco; De Bodt, Marc T; Dillon, Meg; Godey, Benoit; Green, Kevin; Gstoettner, Wolfgang; Hagen, Rudolf; Hagr, Abdulrahman; Han, Demin; Kameswaran, Mohan; Karltorp, Eva; Kompis, Martin; Kuzovkov, Vlad; Lassaletta, Luis; Li, Yongxin; Lorens, Artur; Martin, Jane; Manoj, Manikoth; Mertens, Griet; Mlynski, Robert; Mueller, Joachim; O'Driscoll, Martin; Parnes, Lorne; Pulibalathingal, Sasidharan; Radeloff, Andreas; Raine, Christopher H; Rajan, Gunesh; Rajeswaran, Ranjith; Schmutzhard, Joachim; Skarzynski, Henryk; Skarzynski, Piotr; Sprinzl, Georg; Staecker, Hinrich; Stephan, Kurt; Sugarova, Serafima; Tavora, Dayse; Usami, Shin-Ichi; Yanov, Yuri; Zernotti, Mario; Zorowka, Patrick; de Heyning, Paul Van

    2015-01-01

    Bone conduction implants are useful in patients with conductive and mixed hearing loss for whom conventional surgery or hearing aids are no longer an option. They may also be used in patients affected by single-sided deafness. To establish a consensus on the quality standards required for centers willing to create a bone conduction implant program. To ensure a consistently high level of service and to provide patients with the best possible solution the members of the HEARRING network have established a set of quality standards for bone conduction implants. These standards constitute a realistic minimum attainable by all implant clinics and should be employed alongside current best practice guidelines. Fifteen items are thoroughly analyzed. They include team structure, accommodation and clinical facilities, selection criteria, evaluation process, complete preoperative and surgical information, postoperative fitting and assessment, follow-up, device failure, clinical management, transfer of care and patient complaints.

  4. Silicon technologies ion implantation and thermal treatment

    CERN Document Server

    Baudrant, Annie

    2013-01-01

    The main purpose of this book is to remind new engineers in silicon foundry, the fundamental physical and chemical rules in major Front end treatments: oxidation, epitaxy, ion implantation and impurities diffusion.

  5. Implantable Nanosensors: Towards Continuous Physiologic Monitoring

    OpenAIRE

    Ruckh, Timothy T.; Clark', Heather A.

    2013-01-01

    Continuous physiologic monitoring would add greatly to both home and clinical medical treatment for chronic conditions. Implantable nanosensors are a promising platform for designing continuous monitoring systems. This feature reviews design considerations and current approaches towards such devices.

  6. Moessbauer Studies of Implanted Impurities in Solids

    CERN Multimedia

    2002-01-01

    Moessbauer studies were performed on implanted radioactive impurities in semiconductors and metals. Radioactive isotopes (from the ISOLDE facility) decaying to a Moessbauer isotope were utilized to investigate electronic and vibrational properties of impurities and impurity-defect structures. This information is inferred from the measured impurity hyperfine interactions and Debye-Waller factor. In semiconductors isoelectronic, shallow and deep level impurities have been implanted. Complex impurity defects have been produced by the implantation process (correlated damage) or by recoil effects from the nuclear decay in both semiconductors and metals. Annealing mechanisms of the defects have been studied. \\\\ \\\\ In silicon amorphised implanted layers have been recrystallized epitaxially by rapid-thermal-annealing techniques yielding highly supersaturated, electrically-active donor concentrations. Their dissolution and migration mechanisms have been investigated in detail. The electronic configuration of Sb donors...

  7. Aortic root reoperations after pulmonary autograft implantation

    NARCIS (Netherlands)

    J.A. Bekkers (Jos); L.M.A. Klieverik (Loes Maria Anne); G. Bol-Raap (Goris); J.J.M. Takkenberg (Hanneke); A.J.J.C. Bogers (Ad)

    2010-01-01

    textabstractObjective: To report the results of aortic root reoperations after pulmonary autograft implantation. Methods: All consecutive patients in our prospective Ross research database were selected for analysis, and additional information for patients requiring reoperation was obtained from the

  8. Artificial implantation materials; Sztuczne materialy implantacyjne

    Energy Technology Data Exchange (ETDEWEB)

    Lewandowska-Szumiel, M [Akademia Medyczna, Warsaw (Poland)

    1997-10-01

    The radiation techniques for sterilization of orthopedic materials and high performance biomaterials have been reviewed. The radiation formulation of synthetic biomaterials for implantation and other medical use have been also performed. 18 refs, 3 tabs.

  9. Ion Implantation Processing Technologies for Telecommunications Electronics

    Energy Technology Data Exchange (ETDEWEB)

    Haynes, T E

    2000-05-01

    The subject CRADA was a collaboration between Oak Ridge National Laboratory and Bell Laboratories, Lucent Technologies (formerly AT and T Bell Laboratories) to explore the development of ion implantation technologies for silicon integrated circuit (IC) manufacturing.

  10. Formation of InN phase by sequential ion implantation

    International Nuclear Information System (INIS)

    Santhana Raman, P.; Ravichandran, V.; Nair, K.G.M.; Kesavamoorthy, R.; Kalavathi, S.; Panigrahi, B.K.; Dhara, S.

    2006-01-01

    Formation of InN phase by sequentially implanting nitrogen on indium implanted silica was demonstrated. The growth of embedded InN phase on as-implanted and post-implantation annealed sample was studied using Glancing Incidence X-Ray Diffraction (GIXRD) and Raman spectroscopy. Existence of both cubic and hexagonal phases of InN was observed. Results of irradiation induced ripening of In nanoclusters due to N + ion implantation was also studied. (author)

  11. Management of dental implant fractures. A case history.

    Science.gov (United States)

    Al Quran, Firas A M; Rashan, Bashar A; Al-Dwairi, Ziad N

    2009-01-01

    The widespread use of endosseous osseointegrated implants to replace missing natural teeth increases the chances of implant complications and failures, despite the high initial success rate reported in the literature. Implant fracture is one possible complication that results in ultimate failure of the dental implant. Such a complication poses a management crisis even for the most experienced clinician. This article reports on a case of implant fracture, its possible causes, and how the case was managed.

  12. Accuracy of digital impression in dental implants: A literature review

    OpenAIRE

    Sudabe Kulivand; Maryam Moslemion

    2016-01-01

    Restoration of dental implants remains one of the most challenging aspects of implant dentistry. Although it is not clear whether prosthetic misfit could affect osseointegration, mechanical complications of implant-supported prostheses can be avoided by achieving a good passive fit between the framework and the implants. Passive fit is a difficult concept to define. Obtaining absolute passive fit of the prosthetic framework on implants has been reported to be nearly impossible. Because of ...

  13. REFRACTORY CEPHALEA AND RHINITIS FOLLOWING DENTAL IMPLANT

    Directory of Open Access Journals (Sweden)

    ENRIQUE COSCARÓN-BLANCO

    2018-05-01

    Full Text Available INTRODUCTION: Dental implants are prosthetic devices that are inserted into the thickness of the bone of the maxilla for osseointegration using a screw system. They are increasingly used for both functional and aesthetic reasons. As in any medical or surgical procedure, there are some typical risks and possible sequelae that must be explained and prevented. However, sometimes not-associated-with-implantation rare complications that can cause great morbidity and decrease in the quality of life of the implant recipient can occur. A case of an unusual complication is reported,MATERIAL AND METHODS: A 65-year-old woman presented with a permanent mainly right-sided bilateral nasal obstruction with frequent watery rhinorrhea and headache with retro-orbital and infraorbital irradiation refractory to broad-spectrum antibiotic treatment, corticosteroids and analgesics that she associated with a dental implant two weeks before. . Sinusitis or implant-related complication were ruled out by the dentist and her Primary Care Physician, and therefore she was referred to otorhinolaryngological assessment after radiological study with maxillary sinuses free of disease. The physical examination demostrated inferior obstructive hypertrophic turbinates from the anterior third and thick clear rhinorrhea. After topic tetracaine with adrenaline ,retraction of the turbinates revealed a screw that after breaking the floor of the right nostril entered the thickness of the inferior turbinate. In the left nostril, soil procidence is identified with turbinal contact. An orthopantomography demonstrated the findings described above, highlighting also how the implant was inserted into the skeleton of the inferior turbinate. The sympthoms resolved after removal of the implant. Topical oxymetazoline and corticosteroids provided little relief meanwhile. DISCUSSION AND CONCLUSIONS: The functional objectives sought with dental implants can be compromised by complications such as the

  14. Minimum intervention dentistry: periodontics and implant dentistry.

    Science.gov (United States)

    Darby, I B; Ngo, L

    2013-06-01

    This article will look at the role of minimum intervention dentistry in the management of periodontal disease. It will discuss the role of appropriate assessment, treatment and risk factors/indicators. In addition, the role of the patient and early intervention in the continuing care of dental implants will be discussed as well as the management of peri-implant disease. © 2013 Australian Dental Association.

  15. Top-Cited Articles in Implant Dentistry.

    Science.gov (United States)

    Fardi, Anastasia; Kodonas, Konstantinos; Lillis, Theodoros; Veis, Alexander

    Citation analysis is the field of bibliometrics that uses citation data to evaluate the scientific recognition and the influential performance of a research article in the scientific community. The aim of this study was to conduct a bibliometric analysis of the top-cited articles pertaining to implant dentistry, to analyze the main characteristics, and to display the most interesting topics and evolutionary trends. The 100 top-cited articles published in "Dentistry, Oral Surgery, and Medicine" journals were identified using the Science Citation Index Database. The articles were further reviewed, and basic information was collected, including the number of citations, journals, authors, publication year, study design, level of evidence, and field of study. The highly cited articles in implant dentistry were cited between 199 and 2,229 times. The majority of them were published in four major journals: Clinical Oral Implants Research, International Journal of Oral & Maxillofacial Implants, Journal of Clinical Periodontology, and Journal of Periodontology. The publication year ranged from 1981 to 2009, with 45% published in a nine-year period (2001 to 2009). Publications from the United States (29%) were the most heavily cited, followed by those from Sweden (23%) and Switzerland (17%). The University of Göteborg from Sweden produced the highest number of publications (n = 19), followed by the University of Bern in Switzerland (n = 13). There was a predominance of clinical papers (n = 42), followed by reviews (n = 25), basic science research (n = 21), and proceedings papers (n = 12). Peri-implant tissue healing and health (24%), implant success/failures (19.2%), and biomechanical topics (16.8%) were the most common fields of study. Citation analysis in the field of implant dentistry reveals interesting information about the topics and trends negotiated by researchers and elucidates which characteristics are required for a paper to attain a "classic" status. Clinical

  16. More-reliable SOS ion implantations

    Science.gov (United States)

    Woo, D. S.

    1980-01-01

    Conducting layer prevents static charges from accumulating during implantation of silicon-on-sapphire MOS structures. Either thick conducting film or thinner film transparent to ions is deposited prior to implantation, and gaps are etched in regions to be doped. Grounding path eliminates charge flow that damages film or cracks sapphire wafer. Prevention of charge buildup by simultaneously exposing structure to opposite charges requires equipment modifications less practical and more expensive than deposition of conducting layer.

  17. Implantable Medical Devices; Networking Security Survey

    OpenAIRE

    Siamak Aram; Rouzbeh A. Shirvani; Eros G. Pasero; Mohamd F. Chouikha

    2016-01-01

    The industry of implantable medical devices (IMDs) is constantly evolving, which is dictated by the pressing need to comprehensively address new challenges in the healthcare field. Accordingly, IMDs are becoming more and more sophisticated. Not long ago, the range of IMDs’ technical capacities was expanded, making it possible to establish Internet connection in case of necessity and/or emergency situation for the patient. At the same time, while the web connectivity of today’s implantable dev...

  18. Ion implantation and fracture toughness of ceramics

    International Nuclear Information System (INIS)

    Clark, J.; Pollock, J.T.A.

    1985-01-01

    Ceramics generally lack toughness which is largely determined by the ceramic surface where stresses likely to cause failure are usually highest. Ion implantation has the capacity to improve the surface fracture toughness of ceramics. Significantly reduced ion size and reactivity restrictions exist compared with traditional methods of surface toughening. We are studying the effect of ion implantation on ceramic fracture toughness using indentation testing as the principal tool of analysis

  19. Implantable biomedical microsystems design principles and applications

    CERN Document Server

    Bhunia, Swarup; Sawan, Mohamad

    2015-01-01

    Research and innovation in areas such as circuits, microsystems, packaging, biocompatibility, miniaturization, power supplies, remote control, reliability, and lifespan are leading to a rapid increase in the range of devices and corresponding applications in the field of wearable and implantable biomedical microsystems, which are used for monitoring, diagnosing, and controlling the health conditions of the human body. This book provides comprehensive coverage of the fundamental design principles and validation for implantable microsystems, as well as several major application areas. Each co

  20. Do preoperative antibiotics prevent dental implant complications?

    Science.gov (United States)

    Balevi, Ben

    2008-01-01

    The Cochrane Oral Health Group's Trials Registry, the Cochrane Central Register of Controlled Trials, Medline and Embase were consulted to find relevant work. Searches were made by hand of numerous journals pertinent to oral implantology. There were no language restrictions. Randomised controlled clinical trials (RCT) with a followup of at least 3 months were chosen. Outcome measures were prosthesis failures, implant failures, postoperative infections and adverse events (gastrointestinal, hypersensitivity, etc.). Two reviewers independently assessed the quality and extracted relevant data from included studies. The estimated effect of the intervention was expressed as a risk ratio together with its 95% confidence interval (CI). Numbers-needed-to-treat (NNT) were calculated from numbers of patients affected by implant failures. Meta-analysis was done only if there were studies with similar comparisons that reported the same outcome measure. Significance of any discrepancies between studies was assessed by means of the Cochran's test for heterogeneity and the I2 statistic. Only two RCT met the inclusion criteria. Meta-analysis of these two trials showed a statistically significantly higher number of patients experiencing implant failures in the group not receiving antibiotics (relative risk, 0.22; 95% CI, 0.06-0.86). The NNT to prevent one patient having an implant failure is 25 (95%CI, 13-100), based on a patient implant failure rate of 6% in people not receiving antibiotics. The following outcomes were not statistically significantly linked with implant failure: prosthesis failure, postoperative infection and adverse events (eg, gastrointestinal effects, hypersensitivity). There is some evidence suggesting that 2 g of amoxicillin given orally 1 h preoperatively significantly reduces failures of dental implants placed in ordinary conditions. It remains unclear whether postoperative antibiotics are beneficial, and which is the most effective antibiotic. One dose of