WorldWideScience

Sample records for single volume exchange

  1. Two-stage single-volume exchange transfusion in severe hemolytic disease of the newborn.

    Science.gov (United States)

    Abbas, Wael; Attia, Nayera I; Hassanein, Sahar M A

    2012-07-01

    Evaluation of two-stage single-volume exchange transfusion (TSSV-ET) in decreasing the post-exchange rebound increase in serum bilirubin level, with subsequent reduction of the need for repeated exchange transfusions. The study included 104 neonates with hyperbilirubinemia needing exchange transfusion. They were randomly enrolled into two equal groups, each group comprised 52 neonates. TSSV-ET was performed for the 52 neonates and the traditional single-stage double-volume exchange transfusion (SSDV-ET) was performed to 52 neonates. TSSV-ET significantly lowered rebound serum bilirubin level (12.7 ± 1.1 mg/dL), compared to SSDV-ET (17.3 ± 1.7 mg/dL), p < 0.001. Need for repeated exchange transfusions was significantly lower in TSSV-ET group (13.5%), compared to 32.7% in SSDV-ET group, p < 0.05. No significant difference was found between the two groups as regards the morbidity (11.5% and 9.6%, respectively) and the mortality (1.9% for both groups). Two-stage single-volume exchange transfusion proved to be more effective in reducing rebound serum bilirubin level post-exchange and in decreasing the need for repeated exchange transfusions.

  2. Nuclear structure and the single charge exchange

    International Nuclear Information System (INIS)

    Oset, E.; Strottman, D.

    1979-01-01

    The influence of nuclear structure on meson-induced single-charge-exchange reactions on light nuclei is discussed within the context of the Glauber approximation. Selection rules which are expected to be approximately obeyed in elastic and inelastic pion and kaon scattering are proposed. Theoretical predictions are presented for (π + ,π 0 ) and (K + ,K 0 ) reactions on 13 C. 14 figures

  3. Does Exchange Rate Volatility Affect Korea's Seaborne Import Volume?

    Directory of Open Access Journals (Sweden)

    Chang Beom Kim

    2017-03-01

    Full Text Available This study used monthly data from 2000 to 2015 to analyze the effects of USD/KRW exchange rate volatility on seaborne import volume in Korea. The results of an autoregressive distributed lag (ARDL analysis indicate that USD/KRW exchange rate volatility has a statistically significant negative influence on Korea's seaborne import volume. Moreover, the results of a vector error correction model (VECM analysis found that the USD/KRW exchange rate volatility exhibited short-term unidirectional causality on import volume and real income, and confirmed bidirectional causality between the real effective exchange rate and exchange rate volatility.

  4. Single Minute Exchange of Die. A Case Study Implementation

    Directory of Open Access Journals (Sweden)

    António Carrizo Moreira

    2011-03-01

    Full Text Available The Single Minute Exchange of Die (SMED, a process-based innovation originally published in the mid 1980s, involves the separation and conversion of internal setup operations into external ones. Although very important in increasing productivity SMED experiences are not very widespread in Ibero-America. Accordingly, this article has as its main objective to contribute to the literature addressing this less studied topic: SMED. A case study was put forward emphasizing a process-based view. The main finding is that by implementing SMED techniques the firm managed to eliminate wastefulness and non-added value activities worth around 360 000€, which is about 2% of the firm’s sales volume.

  5. Single- and double-charge exchange at low pion energies

    International Nuclear Information System (INIS)

    Baer, H.W.

    1991-01-01

    A review is given of pion single- and double-charge exchange reactions at incident energies of 25 to 65 MeV leading to isobaric analog states, and in the case of double-charge exchange leading to the ground state of the residual nucleus. The crucial role of the higher nuclear transparency at low pion energies for the analysis of the data in terms of single and double scattering is demonstrated. The large effects on double-charge exchange produced by the spatial correlations in nuclear wave functions are evident. The data on 1f 7/2 nuclei at 35 MeV are used to establish the general validity of a shell-model-based two-amplitude model for these transitions. Recent measurements of the energy dependence between 25 and 65 MeV of double-charge exchange cross sections at forward angles are presented and discussed. 33 refs., 19 figs

  6. Optimization of the Single Staggered Wire and Tube Heat Exchanger

    Directory of Open Access Journals (Sweden)

    Arsana I Made

    2016-01-01

    Full Text Available Wire and tube heat exchanger consists of a coiled tube, and wire is welded on the two sides of it in normal direction of the tube. Generally,wire and tube heat exchanger uses inline wire arrangement between the two sides, whereas in this study, it used staggered wire arrangement that reduces the restriction of convection heat transfer. This study performed the optimization of single staggered wire and tube heat exchanger to increase the capacity and reduce the mass of the heat exchanger. Optimization was conducted with the Hooke-Jeeves method, which aims to optimize the geometry of the heat exchanger, especially on the diameter (dw and the distance between wires (pw. The model developed to present heat transfer correlations on single staggered wire and tube heat exchanger was valid. The maximum optimization factor obtained when the diameter wire was 0.9 mm and the distance between wires (pw was 11 mm with the fref value = 1.5837. It means that the optimized design only using mass of 59,10 % and could transfer heat about 98,5 % from the basis design.

  7. HeartMate II Left Ventricular Assist Device Pump Exchange: A Single-Institution Experience.

    Science.gov (United States)

    Shaikh, Asad F; Joseph, Susan M; Lima, Brian; Hall, Shelley A; Malyala, Rajasekhar; Rafael, Aldo E; Gonzalez-Stawinski, Gonzalo V; Chamogeorgakis, Themistokles

    2017-08-01

    Background  Left ventricular assist devices (LVADs) have revolutionized the treatment of patients with end-stage heart failure. These devices are replaced when pump complications arise if heart transplant is not possible. We present our experience with HeartMate II (HMII (Thoratec, Plesanton, California, United States)) LVAD pump exchange. Materials and Methods  We retrospectively reviewed all cases that required pump exchange due to LVAD complication from November 2011 until June 2016 at a single high-volume institution. The indications, demographics, and outcome were extracted and analyzed. Results  Of 250 total patients with implanted HMII LVADs, 16 (6%) required pump exchange during the study period. The initial indications for LVAD placement in these patients were bridge to transplantation ( n  = 6 [37.5%]) or destination therapy ( n  = 10 [62.5%]). Fifteen patients (93.8%) required pump exchange due to pump thrombosis and 1 (6.2%) due to refractory driveline infection. Nine patients (56.2%) underwent repeat median sternotomy while a left subcostal approach was used in the remaining seven patients. Fifteen patients (93.7%) survived until hospital discharge. During the follow-up period (median, 155 days), 11 patients remained alive and 4 of these underwent successful cardiac transplantation. Conclusion  HMII LVAD pump exchange can be safely performed for driveline infection or pump thrombosis when heart transplantation is not an option. Georg Thieme Verlag KG Stuttgart · New York.

  8. Moderator's view: High-volume plasma exchange: pro, con and consensus.

    Science.gov (United States)

    Kaplan, Andre A

    2017-09-01

    I have been asked to comment on the pro and con opinions regarding high-volume plasma exchange. The authors of both positions have provided cogent arguments and a reasonable approach to choosing the exchange volume for any given therapeutic plasma exchange. The major issue of relevance in this discussion is the nature of the toxins targeted for removal. These parameters include molecular weight, the apparent volume of distribution, the degree of protein binding, the biologic and chemical half-life, and the severity and rapidity of its toxicity. © The Author 2017. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  9. Nuclear isovector giant resonances excited by pion single charge exchange

    International Nuclear Information System (INIS)

    King, B.H.

    1993-07-01

    This thesis is an experimental study of isovector giant resonances in light nuclei excited by pion single charge exchange reactions. Giant dipole resonances in light nuclei are known to be highly structured. For the mass 9 and 13 giant dipole resonances, isospin considerations were found to be very important to understanding this structure. by comparing the excitation functions from cross section measurements of the (π + , π 0 ) and (π, π 0 ) inclusive reactions, the authors determined the dominant isospin structure of the analog IVGR's. The comparison was made after decomposing the cross section into resonant and non-resonant components. This decomposition is made in the framework of strong absorption and quasi-free scattering. Measurements in the region of the isovector giant dipole resonances (IVGDR) were made to cover the inclusive angular distributions out to the second minimum. Study of the giant resonance decay process provides further understanding of the resonances. This study was carried out by observing the (π + , π 0 p) coincident reactions involving the resonances of 9 B and 13 N excited from 9 Be and 13 C nuclei. These measurements determined the spectra of the decay protons. This method also permitted a decomposition of the giant resonances into their isospin components. The multipolarities of the resonances were revealed by the decay proton angular correlations which, for dipoles, are of the form 1 + A 2 P 2 (cos θ)

  10. Price volatility, trading volume, and market depth in Asian commodity futures exchanges

    Directory of Open Access Journals (Sweden)

    Tanachote Boonvorachote

    2016-01-01

    Full Text Available This paper empirically investigates the impact of trading activity including trading volume and open interest on price volatility in Asian futures exchanges. Trading volume and open interest represent market information for investors. This study uses three different definitions of volatility: (1 daily volatility measured by close-to-close returns, (2 non-trading volatility measured by close-to-open returns, and (3 trading volatility measured by open-to-close returns. The impact of trading volume and open interest on price volatility is investigated. Following Bessembinder and Seguin (1993, volume and open interest are divided into expected and unexpected components. The GARCH (1,1 model is employed using expected and unexpected components of trading activity (volume and open interest as explanatory variables. The results show a positive contemporaneous relationship between expected and unexpected trading volume and volatility, while open interest mitigates volatility. Policy makers can use these findings to suggest to investors that trading activity (volume and open interest is a proxy of market information flowing to exchanges, especially unexpected trading activity. New information flowing to exchanges can mostly be noticed in unexpected trading volumes and open interests.

  11. Effects of respiratory rate and tidal volume on gas exchange in total liquid ventilation.

    Science.gov (United States)

    Bull, Joseph L; Tredici, Stefano; Fujioka, Hideki; Komori, Eisaku; Grotberg, James B; Hirschl, Ronald B

    2009-01-01

    Using a rabbit model of total liquid ventilation (TLV), and in a corresponding theoretical model, we compared nine tidal volume-respiratory rate combinations to identify a ventilator strategy to maximize gas exchange, while avoiding choked flow, during TLV. Nine different ventilation strategies were tested in each animal (n = 12): low [LR = 2.5 breath/min (bpm)], medium (MR = 5 bpm), or high (HR = 7.5 bpm) respiratory rates were combined with a low (LV = 10 ml/kg), medium (MV = 15 ml/kg), or high (HV = 20 ml/kg) tidal volumes. Blood gases and partial pressures, perfluorocarbon gas content, and airway pressures were measured for each combination. Choked flow occurred in all high respiratory rate-high volume animals, 71% of high respiratory rate-medium volume (HRMV) animals, and 50% of medium respiratory rate-high volume (MRHV) animals but in no other combinations. Medium respiratory rate-medium volume (MRMV) resulted in the highest gas exchange of the combinations that did not induce choke. The HRMV and MRHV animals that did not choke had similar or higher gas exchange than MRMV. The theory predicted this behavior, along with spatial and temporal variations in alveolar gas partial pressures. Of the combinations that did not induce choked flow, MRMV provided the highest gas exchange. Alveolar gas transport is diffusion dominated and rapid during gas ventilation but is convection dominated and slow during TLV. Consequently, the usual alveolar gas equation is not applicable for TLV.

  12. Volume production of polarization controlled single-mode VCSELs

    Science.gov (United States)

    Grabherr, Martin; King, Roger; Jäger, Roland; Wiedenmann, Dieter; Gerlach, Philipp; Duckeck, Denise; Wimmer, Christian

    2008-02-01

    Over the past 3 years laser based tracking systems for optical PC mice have outnumbered the traditional VCSEL market datacom by far. Whereas VCSEL for datacom in the 850 nm regime emit in multipe transverse modes, all laser based tracking systems demand for single-mode operation which require advanced manufacturing technology. Next generation tracking systems even require single-polarization characteristics in order to avoid unwanted movement of the pointer due to polarization flips. High volume manufacturing and optimized production methods are crucial for achieving the addressed technical and commercial targets of this consumer market. The resulting ideal laser source which emits single-mode and single-polarization at low cost is also a promising platform for further applications like tuneable diode laser absorption spectroscopy (TDLAS) or miniature atomic clocks when adapted to the according wavelengths.

  13. Optimal target search on a fast-folding polymer chain with volume exchange

    DEFF Research Database (Denmark)

    Lomholt, Michael Andersen; Ambjörnsson, T.; Metzler, R.

    2005-01-01

    We study the search process of a target on a rapidly folding polymer ("DNA") by an ensemble of particles ("proteins"), whose search combines 1D diffusion along the chain, Lévy type diffusion mediated by chain looping, and volume exchange. A rich behavior of the search process is obtained...

  14. Fluid Composition Impact on Heat Exchangers Volume of Closed-Cycle Gas Turbine Plant

    Directory of Open Access Journals (Sweden)

    G. A. Shafikov

    2016-01-01

    Full Text Available The paper subject is a choice of the fluid composition for the heat exchangers (HE of a closed-cycle gas turbine plant (CGTP.The study of the fluid composition impact on heater dimensions is a subtask in designing a 25 kW long-resourced CGTP with gas temperature of 1273 K before the turbine for a remote autonomous consumer of energy. The aim of this study is to find the optimal mixture to have the HE minimum volumes of the CGTP. Herein, heating is provided through the heat supply from the combustion of various cheap kinds of fuel, which, in turn, may result in contaminating heat exchange surfaces. In the analysis an additional condition is that it is necessary to reduce the level of contamination of heat exchange surfaces, which is reached by using a HE tubular matrix and a turbulent regime of flow.A mixture of inert gas and helium- xenon is used, as a fluid, to increase the life of the plant. The paper illustrates how the thermal conductivity and viscosity of the helium-xenon mixture depend on the percentage composition of helium in the mixture.The paper describes in detail the effect of the helium-xenon mixture composition on the mixture flow parameters in the preheater and on the volume of its matrix. In addition, it gives the calculation results on how the helium-xenon mixture composition effects on the volumes of the regenerator and cooler matrices.After assessing the impact of the helium-xenon mixture composition on the HE parameters their comparison is conducted in terms of volume and cost of materials from which to make them. From these data a conclusion is drawn that the heater volume has a great effect on the cost of heat exchange equipment, and it is advisable to choose the mixture composition with which its volume is minimal.

  15. Quantitative Synthesis and Component Analysis of Single-Participant Studies on the Picture Exchange Communication System

    Science.gov (United States)

    Tincani, Matt; Devis, Kathryn

    2011-01-01

    The "Picture Exchange Communication System" (PECS) has emerged as the augmentative communication intervention of choice for individuals with autism spectrum disorder (ASD), with a supporting body of single-participant studies. This report describes a meta-analysis of 16 single-participant studies on PECS with percentage of nonoverlapping data…

  16. Volume Averaging Theory (VAT) based modeling and closure evaluation for fin-and-tube heat exchangers

    Science.gov (United States)

    Zhou, Feng; Catton, Ivan

    2012-10-01

    A fin-and-tube heat exchanger was modeled based on Volume Averaging Theory (VAT) in such a way that the details of the original structure was replaced by their averaged counterparts, so that the VAT based governing equations can be efficiently solved for a wide range of parameters. To complete the VAT based model, proper closure is needed, which is related to a local friction factor and a heat transfer coefficient of a Representative Elementary Volume (REV). The terms in the closure expressions are complex and sometimes relating experimental data to the closure terms is difficult. In this work we use CFD to evaluate the rigorously derived closure terms over one of the selected REVs. The objective is to show how heat exchangers can be modeled as a porous media and how CFD can be used in place of a detailed, often formidable, experimental effort to obtain closure for the model.

  17. Statistical analysis of entropy generation in longitudinally finned tube heat exchanger with shell side nanofluid by a single phase approach

    Directory of Open Access Journals (Sweden)

    Konchada Pavan Kumar

    2016-06-01

    Full Text Available The presence of nanoparticles in heat exchangers ascertained increment in heat transfer. The present work focuses on heat transfer in a longitudinal finned tube heat exchanger. Experimentation is done on longitudinal finned tube heat exchanger with pure water as working fluid and the outcome is compared numerically using computational fluid dynamics (CFD package based on finite volume method for different flow rates. Further 0.8% volume fraction of aluminum oxide (Al2O3 nanofluid is considered on shell side. The simulated nanofluid analysis has been carried out using single phase approach in CFD by updating the user-defined functions and expressions with thermophysical properties of the selected nanofluid. These results are thereafter compared against the results obtained for pure water as shell side fluid. Entropy generated due to heat transfer and fluid flow is calculated for the nanofluid. Analysis of entropy generation is carried out using the Taguchi technique. Analysis of variance (ANOVA results show that the inlet temperature on shell side has more pronounced effect on entropy generation.

  18. Comparison of Moving Boundary and Finite-Volume Heat Exchanger Models in the Modelica Language

    Directory of Open Access Journals (Sweden)

    Adriano Desideri

    2016-05-01

    Full Text Available When modeling low capacity energy systems, such as a small size (5–150 kWel organic Rankine cycle unit, the governing dynamics are mainly concentrated in the heat exchangers. As a consequence, the accuracy and simulation speed of the higher level system model mainly depend on the heat exchanger model formulation. In particular, the modeling of thermo-flow systems characterized by evaporation or condensation requires heat exchanger models capable of handling phase transitions. To this aim, the finite volume (FV and the moving boundary (MB approaches are the most widely used. The two models are developed and included in the open-source ThermoCycle Modelica library. In this contribution, a comparison between the two approaches is presented. An integrity and accuracy test is designed to evaluate the performance of the FV and MB models during transient conditions. In order to analyze how the two modeling approaches perform when integrated at a system level, two organic Rankine cycle (ORC system models are built using the FV and the MB evaporator model, and their responses are compared against experimental data collected on an 11 kWel ORC power unit. Additionally, the effect of the void fraction value in the MB evaporator model and of the number of control volumes (CVs in the FV one is investigated. The results allow drawing general guidelines for the development of heat exchanger dynamic models involving two-phase flows.

  19. Comparative study of Nusselt number for a single phase fluid flow using plate heat exchanger

    Directory of Open Access Journals (Sweden)

    Shanmugam Rajasekaran

    2016-01-01

    Full Text Available In this study, the plate heat exchangers are used for various applications in the industries for heat exchange process such as heating, cooling and condensation. The performance of plate heat exchanger depends on many factors such as flow arrangements, plate design, chevron angle, enlargement factor, type of fluid used, etc. The various Nusselt number correlations are developed by considering that the water as a working fluid. The main objective of the present work is to design the experimental set-up for a single phase fluid flow using plate heat exchanger and studied the heat transfer performance. The experiments are carried out for various Reynolds number between 500 and 2200, the heat transfer coefficients are estimated. Based on the experimental results the new correlation is developed for Nusselt number and compared with an existing correlation.

  20. The Influence of Stock Exchange Transactions on the Volume of Capital Investments in Real Sectors of the Ukrainian Economy

    Directory of Open Access Journals (Sweden)

    Strielnikov Roman M.

    2017-09-01

    Full Text Available It is determined that insufficient attention is paid to the issues of influence of cash flows that are formed in the national stock market on the size of capital investments in real sectors of the national economy. Therefore this direction of scientific and practical research is topical. It is proved that the purchase of securities that the buyer intends to resell within three months cannot be classified as an investment, and the buyer — as an investor. It is found that during the last ten years the main source of financing of capital investments was the position “Own funds of enterprises and institutions”. When considering exchange securities contracts at stock markets there singled out financial instruments that can influence the size of capital investments in real sectors of the economy, namely, shares and bonds of enterprises. The conducted correlation analysis showed that there is a strong correlation between exchange contracts with original issue shares and the volumes of capital investments in real sectors of the economy, which indicates that the capitalization of the assets of issuers of shares contributes to increasing the opportunities for capital investments in the whole country.

  1. Influence of heat exchange of reservoir with rocks on hot gas injection via a single well

    Science.gov (United States)

    Nikolaev, Vladimir E.; Ivanov, Gavril I.

    2017-11-01

    In the computational experiment the influence of heat exchange through top and bottom of the gas-bearing reservoir on the dynamics of temperature and pressure fields during hot gas injection via a single well is investigated. The experiment was carried out within the framework of modified mathematical model of non-isothermal real gas filtration, obtained from the energy and mass conservation laws and the Darcy law. The physical and caloric equations of state together with the Newton-Riemann law of heat exchange of gas reservoir with surrounding rocks, are used as closing relations. It is shown that the influence of the heat exchange with environment on temperature field of the gas-bearing reservoir is localized in a narrow zone near its top and bottom, though the size of this zone is increased with time.

  2. Reduction In Setup Time By Single Minute Exchange Of Dies SMED Methodology

    Directory of Open Access Journals (Sweden)

    Pallavi A. Gade

    2015-08-01

    Full Text Available Life is a race if you dont chase it someone is definitely chase you and will go ahead. Hence to survive in todays business world every manufacturer has to have some idea and plans for their betterment. Market scenario has nearly change after 1990s that every manufacturer must go through the global competition demand for short lead time demand for variety small lot sizes and also proliferation of OEMs. If we have to increase the frequency of delivery without compromising the quality Single Minute Exchange of Dies is the answer. Single Minute Exchange of Dies is not only apply to bottleneck machines it is to be implemented company wide and aim must be to bring all setup time to less than ten minutes in this paper some techniques basic procedure problems faced by companies are discussed and solution for them are suggested.

  3. Sensitivity of the amplitude of the single muscle fibre action potential to microscopic volume conduction parameters

    NARCIS (Netherlands)

    Alberts, B.A.; Rutten, Wim; Wallinga, W.; Boom, H.B.K.

    1988-01-01

    A microscopic model of volume conduction was applied to examine the sensitivity of the single muscle fibre action potential to variations in parameters of the source and of the volume conductor, such as conduction velocity, intracellular conductivity and intracellular volume fraction. The model

  4. Effect of ligand substitution on the exchange interactions in {Mn12}-type single-molecule magnets

    OpenAIRE

    Boukhvalov, D. W.; Dobrovitski, V. V.; Kögerler, P.; Al-Saqer, M.; Katsnelson, M. I.; Lichtenstein, A. I.; Harmon, B. N.

    2010-01-01

    We investigate how the ligand substitution affects the intra-molecular spin exchange interactions, studying a prototypal family of single-molecule magnets comprising dodecanuclear cluster molecules [Mn12O12(COOR)16]. We identify a simple scheme based on accumulated Pauling electronegativity numbers (a.e.n.) of the carboxylate ligand groups (R). The redistribution of the electron density, controlled by a.e.n. of a ligand, changes the degree of hybridization between 3d electrons of manganese an...

  5. Exchange interaction of strongly anisotropic tripodal erbium single-ion magnets with metallic surfaces

    DEFF Research Database (Denmark)

    Dreiser, Jan; Wäckerlin, Christian; Ali, Md. Ehesan

    2014-01-01

    We present a comprehensive study of Er(trensal) single-ion magnets deposited in ultrahigh vacuum onto metallic surfaces. X-ray photoelectron spectroscopy reveals that the molecular structure is preserved after sublimation, and that the molecules are physisorbed on Au(111) while they are chemisorbed....... Furthermore XMCD indicates a weak antiferromagnetic exchange coupling between the single-ion magnets and the ferromagnetic Ni/Cu(100) substrate. For the latter case, spin-Hamiltonian fits to the XMCD M(H) suggest a significant structural distortion of the molecules. Scanning tunneling microscopy reveals...

  6. 2D IR cross peaks reveal hydrogen-deuterium exchange with single residue specificity.

    Science.gov (United States)

    Dunkelberger, Emily B; Woys, Ann Marie; Zanni, Martin T

    2013-12-12

    A form of chemical exchange, hydrogen-deuterium exchange (HDX), has long been used as a method for studying the secondary and tertiary structure of peptides and proteins using mass spectrometry and NMR spectroscopy. Using two-dimensional infrared (2D IR) spectroscopy, we resolve cross peaks between the amide II band and a (13)C(18)O isotope-labeled amide I band, which we show measures HDX with site-specific resolution. By rapidly scanning 2D IR spectra using mid-IR pulse shaping, we monitor the kinetics of HDX exchange on-the-fly. For the antimicrobial peptide ovispirin bound to membrane bilayers, we find that the amide II peak decays with a biexponential with rate constants of 0.54 ± 0.02 and 0.12 ± 0.01 min(-1), which is a measure of the overall HDX in the peptide. The cross peaks between Ile-10-labeled ovispirin and the amide II mode, which specifically monitor HDX kinetics at Ile-10, decay with a single rate constant of 0.36 ± 0.1 min(-1). Comparing this exchange rate to theoretically determined exchange rates of Ile-10 for ovispirin in a solution random coil configuration, the exchange rate at Ile-10 is at least 100 times slower, consistent with the known α-helix structure of ovispirin in bilayers. Because backbone isotope labels produce only a very small shift of the amide II band, site-specific HDX cannot be measured with FTIR spectroscopy, which is why 2D IR spectroscopy is needed for these measurements.

  7. Computing H/D-Exchange rates of single residues from data of proteolytic fragments

    Directory of Open Access Journals (Sweden)

    Althaus Ernst

    2010-08-01

    Full Text Available Abstract Background Protein conformation and protein/protein interaction can be elucidated by solution-phase Hydrogen/Deuterium exchange (sHDX coupled to high-resolution mass analysis of the digested protein or protein complex. In sHDX experiments mutant proteins are compared to wild-type proteins or a ligand is added to the protein and compared to the wild-type protein (or mutant. The number of deuteriums incorporated into the polypeptides generated from the protease digest of the protein is related to the solvent accessibility of amide protons within the original protein construct. Results In this work, sHDX data was collected on a 14.5 T FT-ICR MS. An algorithm was developed based on combinatorial optimization that predicts deuterium exchange with high spatial resolution based on the sHDX data of overlapping proteolytic fragments. Often the algorithm assigns deuterium exchange with single residue resolution. Conclusions With our new method it is possible to automatically determine deuterium exchange with higher spatial resolution than the level of digested fragments.

  8. Simplified thermal-hydraulic analysis of single phase natural circulation circuit with two heat exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Pinheiro, Larissa Cunha; Su, Jian, E-mail: larissa@lasme.coppe.ufrj.br, E-mail: sujian@lasme.coppe.ufrj.br [Coordenacao dos Programas de Pos-Graduacao em Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenhraria Nuclear; Cotta, Renato Machado, E-mail: cotta@mecanica.coppe.ufrj.br [Coordenacao dos Programas de Pos-Graduacao em Engenharia (POLI/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Dept. de Engenharia Mecanica

    2015-07-01

    Single phase natural circulation circuits composed of two convective heat exchangers and connecting tubes are important for the passive heat removal from spent fuel pools (SFP). To keep the structural integrity of the stored spent fuel assemblies, continuously cooling has to be provided in order to avoid increase at the pool temperature and subsequent uncovering of the fuel and enhanced reaction between water and metal releasing hydrogen. Decay heat can achieve considerably high amounts of energy e.g. in the AP1000, considering the emergency fuel assemblies, the maximum heat decay will reach 13 MW in the 15th day (Westinghouse Electric Company, 2010). A highly efficient alternative to do so is by means of natural circulation, which is cost-effective compared to active cooling systems and is inherently safer since presents less associated devices and no external work is required. Many researchers have investigated safety and stability aspects of natural circulation loops (NCL). However, there is a lack of literature concerning the improvement of NCL through a standard unified methodology, especially for natural circulation circuits with two heat exchangers. In the present study, a simplified thermal-hydraulic analysis of single phase natural circulation circuit with two heat exchanges is presented. Relevant dimensionless key groups were proposed to for the design and safety analysis of a scaled NCL for the cooling of spent fuel storage pool with convective cooling and heating. (author)

  9. INVESTIGATION OF DNA REPAIR BY SISTER CHROMATID EXCHANGE (SCE) ANALYSIS AND THE ALKALINE SINGLE CELL GEL ASSAY (SCG) IN MAMMALIAN GO-LYMPHOCYTES AFTER IN VITRO EXPOSURE TO ETHYLENE OXIDE (EO)

    Science.gov (United States)

    Investigation ofDNA Repair by Sister Chromatid Exchange (SCE) Analysis and the Alkaline Single Cell Gel Assay (SCG) in Mammalian Go-Lymphocytes after In Vitro Exposure to Ethylene Oxide (EO). EO is a large volume chemical used primarily as an intermediate in manufacturing...

  10. Single-pass multi-view volume rendering

    OpenAIRE

    Hübner, T; Pajarola, R

    2007-01-01

    In this paper, we introduce a new direct volume rendering (DVR) algorithm for multi-view auto-stereoscopic displays. Common multi-view methods perform multi-pass rendering (one pass for each view) and subsequent image compositing and masking for generating multiple views. The rendering time increases therefore linearly with the number of views, but sufficient frame-rates are achieved by sub-resolution rendering, at the expense of degraded image quality. To overcome these disadvantages for DVR...

  11. Concentration and separation of trace metals from seawater using a single anion exchange bead

    International Nuclear Information System (INIS)

    Koide, M.; Lee, D.S.; Stallard, M.O.

    1984-01-01

    A technique has been developed for the quantitative adsorption of trace metals onto a single anion exchange bead. The application to the assay of trace metals in seawater was explored with the following radionuclides: 109 Cd, 103 Pd, 192 Ir, 195 Au, 237 Pu, and /sup 99m/Tc. The major ions, Na + , K + , Mg 2+ , and Ca 2+ exist primarily as positively charged species in seawater under nearly all conditions and did not interfere in the adsorption of anionic forms of trace metals onto the single bead. Three types of applications of the technique were investigated: (A) determination of metals in seawater by the direct adsorption onto a single bead without prior concentration, with or without a subsequent desorption from the bead (e.g., Cd, Zn); (B) determination of metals in seawater by the adsorption onto a single bead after a preconcentration step from several liters of seawater (e.g., Pd, Au, Ir), and (C) increasing the yield of Pu and Tc onto a single bead for improved sensitivity in mass spectrometric analyses

  12. Giant volume magnetostriction in the Y{sub 2}Fe{sub 17} single crystal at room temperature

    Energy Technology Data Exchange (ETDEWEB)

    Nikitin, S. A., E-mail: nikitin@phys.msu.ru; Pankratov, N. Yu.; Smarzhevskaya, A. I.; Politova, G. A. [Physics Faculty, Lomonosov Moscow State University, Moscow 119992 (Russian Federation); Pastushenkov, Yu. G., E-mail: yupast@mail.ru; Skokov, K. P. [Physics Faculty, Tver State University, 170100 Tver (Russian Federation); Moral, A. del [Laboratorio de Magnetismo de Slidos, Departamento de Fisica de Materia Condensada and Instituto de Ciencia de Materiales de Aragn, Facultad de Ciencias, Universidad de Zaragoza-C.S.I.C, E-50009 Zaragoza (Spain)

    2015-05-21

    An investigation of the Y{sub 2}Fe{sub 17} compound belonging to the class of intermetallic alloys of rare-earth and 3d-transition metals is presented. The magnetization, magnetostriction, and thermal expansion of the Y{sub 2}Fe{sub 17} single crystal were studied. The forced magnetostriction and magnetostriction constants were investigated in the temperature range of the magnetic ordering close to the room temperature. The giant field induced volume magnetostriction was discovered in the room temperature region in the magnetic field up to 1.2 T. The contributions of both anisotropic single-ion and isotropic pair exchange interactions to the volume magnetostriction and magnetostriction constants were determined. The experimental results were interpreted within the framework of the Standard Theory of Magnetostriction and the Landau thermodynamic theory. It was found out that the giant values of the volume magnetostriction were caused by the strong dependence of the 3d-electron Coulomb charge repulsion on the deformations and width of the 3d-electron energy band.

  13. Spin quantum tunneling via entangled states in a dimer of exchange coupled single-molecule magnets

    Science.gov (United States)

    Tiron, R.; Wernsdorfer, W.; Aliaga-Alcalde, N.; Foguet-Albiol, D.; Christou, G.

    2004-03-01

    A new family of supramolecular, antiferromagnetically exchange-coupled dimers of single-molecule magnets (SMMs) has recently been reported [W. Wernsdorfer, N. Aliaga-Alcalde, D.N. Hendrickson, and G. Christou, Nature 416, 406 (2002)]. Each SMM acts as a bias on its neighbor, shifting the quantum tunneling resonances of the individual SMMs. Hysteresis loop measurements on a single crystal of SMM-dimers have now established quantum tunneling of the magnetization via entangled states of the dimer. This shows that the dimer really does behave as a quantum-mechanically coupled dimer. The transitions are well separated, suggesting long coherence times compared to the time scale of the energy splitting. This result is of great importance if such systems are to be used for quantum computing. It also allows the measurement of the longitudinal and transverse superexchange coupling constants [Phys. Rev. Lett. 91, 227203 (2003)].

  14. Direct exchange between silicon nanocrystals and tunnel oxide traps under illumination on single electron photodetector

    Energy Technology Data Exchange (ETDEWEB)

    Chatbouri, S., E-mail: Samir.chatbouri@yahoo.com; Troudi, M.; Sghaier, N.; Kalboussi, A. [Avenue de I’environnement, Université de Monastir, Laboratoire de Micro électronique et Instrumentation (LR13ES12), Faculté des Sciences de Monastir (Tunisia); Aimez, V. [Université de Sherbrooke, Laboratoire Nanotechnologies et Nanosystémes (UMI-LN2 3463), Université de Sherbrooke—CNRS—INSA de Lyon-ECL-UJF-CPE Lyon, Institut Interdisciplinaire d’Innovation Technologique (Canada); Drouin, D. [Avenue de I’environnement, Université de Monastir, Laboratoire de Micro électronique et Instrumentation (LR13ES12), Faculté des Sciences de Monastir (Tunisia); Souifi, A. [Institut des Nanotechnologies de Lyon—site INSA de Lyon, UMR CNRS 5270 (France)

    2016-09-15

    In this paper we present the trapping of photogenerated charge carriers for 300 s resulted by their direct exchange under illumination between a few silicon nanocrystals (ncs-Si) embedded in an oxide tunnel layer (SiO{sub x} = 1.5) and the tunnel oxide traps levels for a single electron photodetector (photo-SET or nanopixel). At first place, the presence of a photocurrent limited in the inversion zone under illumination in the I–V curves confirms the creation of a pair electron/hole (e–h) at high energy. This photogenerated charge carriers can be trapped in the oxide. Using the capacitance-voltage under illumination (the photo-CV measurements) we show a hysteresis chargement limited in the inversion area, indicating that the photo-generated charge carriers are stored at traps levels at the interface and within ncs-Si. The direct exchange of the photogenerated charge carriers between the interface traps levels and the ncs-Si contributed on the photomemory effect for 300 s for our nanopixel at room temperature.

  15. Cyanide single-molecule magnets exhibiting solvent dependent reversible "on" and "off" exchange bias behavior

    DEFF Research Database (Denmark)

    Pinkowicz, Dawid; Southerland, Heather I.; Avendaño, Carolina

    2015-01-01

    Co/Os analogue (PPN){[Mn(III)(salphen)(MeOH)]2[Co(III)0.92Os(III)0.08(CN)6]}·7MeOH were undertaken. It was found that all compounds exhibit switchable single-molecule magnet (SMM) and exchange-bias behavior depending on the interstitial methanol content. The pristine (PPN){[Mn(salphen)(MeOH)]2[Os......(CN)6]}·7MeOH (Mn2Os·7MeOH) behaves as an SMM with an effective barrier for the magnetization reversal, (Ueff/kB), of 17.1 K. Upon desolvation, Mn2Os exhibits an increase of Ueff/kB to 42.0 K and an opening of the hysteresis loop observable at 1.8 K. Mn2Os·7MeOH shows also exchange-bias behavior...... with magnetic hysteresis loops exhibiting a shift in the quantum tunneling to 0.25 T from zero-field. The Fe(III) and Ru(III) analogues were prepared as reference compounds for assessing the effect of the 5d versus 4d and 3d metal ions on the SMM properties. These compounds are also SMMs and exhibit similar...

  16. Inhibitors of pendrin anion exchange identified in a small molecule screen increase airway surface liquid volume in cystic fibrosis.

    Science.gov (United States)

    Haggie, Peter M; Phuan, Puay-Wah; Tan, Joseph-Anthony; Zlock, Lorna; Finkbeiner, Walter E; Verkman, A S

    2016-06-01

    Pendrin (SLC26A4) is a Cl(-)/anion exchanger expressed in the epithelium of inflamed airways where it is thought to facilitate Cl(-) absorption and HCO3 (-) secretion. Studies using pendrin knockout mice and airway epithelial cells from hearing-impaired subjects with pendrin loss of function suggest involvement of pendrin in inflammatory lung diseases, including cystic fibrosis (CF), perhaps by regulation of airway surface liquid (ASL) volume. Here we identified small-molecule pendrin inhibitors and demonstrated their efficacy in increasing ASL volume. A cell-based, functional high-throughput screen of ∼36,000 synthetic small molecules produced 3 chemical classes of inhibitors of human pendrin. After structure-activity studies, tetrahydropyrazolopyridine and pyrazolothiophenesulfonamide compounds reversibly inhibited pendrin-facilitated Cl(-) exchange with SCN(-), I(-), NO3 (-), and HCO3 (-) with drug concentration causing 50% inhibition down to ∼2.5 μM. In well-differentiated primary cultures of human airway epithelial cells from non-CF and CF subjects, treatment with IL-13, which causes inflammation with strong pendrin up-regulation, strongly increased Cl(-)/HCO3 (-) exchange and the increase was blocked by pendrin inhibition. Pendrin inhibition significantly increased ASL depth (by ∼8 μm) in IL-13-treated non-CF and CF cells but not in untreated cells. These studies implicate the involvement of pendrin-facilitated Cl(-)/HCO3 (-) in the regulation of ASL volume and suggest the utility of pendrin inhibitors in inflammatory lung diseases, including CF.-Haggie, P. M., Phuan, P.-W., Tan, J.-A., Zlock, L., Finkbeiner, W. E., Verkman, A. S. Inhibitors of pendrin anion exchange identified in a small molecule screen increase airway surface liquid volume in cystic fibrosis. © FASEB.

  17. The Single Minute Exchange of Die Methodology in a High-Mix Processing Line

    Directory of Open Access Journals (Sweden)

    Filla Jan

    2016-06-01

    Full Text Available Because of turbulence in the economic environment, enterprises must react flexibly to the changing demands of their customers. Thus, a changeover process is required. If an enterprise has a large product portfolio, there are basically only two process options; to integrate production into large batches or to change the production programme frequently. Frequent changes associated with the changeover process of machinery are optimized by using the SMED method. The main goal of this paper is to apply SMED (Single Minute Exchange of Die to a High-Mix processing line. The case study is undertaken in a flat glass processing company which manufactures hundreds of types of products. The results of the case study demonstrate that it is possible to save up to 30% annually of the time currently spent on changeovers.

  18. Anisotropic magnetoresistance and anomalous Nernst effect in exchange biased permalloy/(1 0 0) NiO single-crystal

    Energy Technology Data Exchange (ETDEWEB)

    Holanda, J., E-mail: joseholanda@df.ufpe.br; Maior, D.S.; Azevedo, A.; Rezende, S.M.

    2017-06-15

    Highlights: • We have investigated the anisotropic magnetoresistance (AMR) and the anomalous Nernst effect (ANE) in an exchange-biased bilayer Py/(100) NiO single-Crystal. • The shift of the hysteresis loop, measured with the different techniques, yield approximately the same value of H{sub EB}. • In spite of the measurement techniques be based in different physical phenomena, our results confirm the robustness of the exchange anisotropy at the Py/NiO interface. • The strength of the anomalous Nernst effect for the exchange-biased permalloy film is compared to values measured in non biased films. - Abstract: We have investigated the anisotropic magnetoresistance (AMR) and the anomalous Nernst effect (ANE) in an exchange-biased bilayer consisting of a thin film of permalloy deposited on a single crystal antiferromagnetic NiO (1 0 0). The exchange bias field (H{sub EB}) value was obtained by means of AMR, ANE and magnetization hysteresis measurements. The shift of the hysteresis loop, measured with the three different techniques, yield approximately the same value of H{sub EB.} In spite of the measurement techniques be based in different physical phenomena, our results confirm the robustness of the exchange anisotropy at the Py/NiO interface. The strength of the anomalous Nernst effect for the exchange-biased permalloy film is compared to values measured in non biased films.

  19. 70 GeV proton volume capture into channeling mode with a bent Si single crystal

    International Nuclear Information System (INIS)

    Chesnokov, Yu.A.; Galyaev, N.A.; Kotov, V.I.; Tsarik, S.V.; Zapol'skij, V.N.

    1990-01-01

    The existence of the volume capture of 70 GeV protons with a Si bent single crystal of (111) orientation into the channeling mode gas experimentally been proved. The data on the probability of capturing protons into the channeling mode versus the bending radius of the crystal have been obtained together with the information on the dynamics of volume captured particle dechanneling. 10 refs

  20. A high-throughput 2D-analytical technique to obtain single protein parameters from complex cell lysates for in silico process development of ion exchange chromatography.

    Science.gov (United States)

    Kröner, Frieder; Elsäßer, Dennis; Hubbuch, Jürgen

    2013-11-29

    The accelerating growth of the market for biopharmaceutical proteins, the market entry of biosimilars and the growing interest in new, more complex molecules constantly pose new challenges for bioseparation process development. In the presented work we demonstrate the application of a multidimensional, analytical separation approach to obtain the relevant physicochemical parameters of single proteins in a complex mixture for in silico chromatographic process development. A complete cell lysate containing a low titre target protein was first fractionated by multiple linear salt gradient anion exchange chromatography (AEC) with varying gradient length. The collected fractions were subsequently analysed by high-throughput capillary gel electrophoresis (HT-CGE) after being desalted and concentrated. From the obtained data of the 2D-separation the retention-volumes and the concentration of the single proteins were determined. The retention-volumes of the single proteins were used to calculate the related steric-mass action model parameters. In a final evaluation experiment the received parameters were successfully applied to predict the retention behaviour of the single proteins in salt gradient AEC. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Volume 2, U-Information networking: the development of national or regional scientific information exchange

    OpenAIRE

    1994-01-01

    In this manual a complete overview is provided of the procedures to develop national or regional information exchange networks within a developing country framework. Attention is given to types of information which need to be exchanged, identification of network components, the network structure, the role and responsibilities of a dispatch centre and its staff. As an example of an operational network an extensive description is given of the RECOSCIX-WIO project including its history, servi...

  2. Picture Exchange Communication System with Individuals with Developmental Disabilities: A Meta-Analysis of Single Subject Studies

    Science.gov (United States)

    Hart, Stephanie L.; Banda, Devender R.

    2010-01-01

    Picture Exchange Communication System (PECS) is a picture-based communication strategy used to teach communication skills to persons with developmental disabilities including autism. This article systematically reviews 13 published single-subject studies to examine the effectiveness of PECS, the effects of PECS on speech and problem behaviors,…

  3. Analysis of Right Issue Announcement Effect toward Stock Price Movement and Stock Trading Volume within Issuer in Indonesia Stock Exchange

    Directory of Open Access Journals (Sweden)

    Wilson Yaputra Yakup

    2016-05-01

    Full Text Available The purpose of this study were to identify and analyze the rights issue effect to the stock price, the effect of the rights issue on stock trading volume, the correlation between stock prices before and after the right issue, as well as the correlation between volume of trading activity before the right issue and after that event. The objects of the study are the companies listed on Indonesia Stock Exchange (JSX. The hypothesis stated that right issues have a significant effect on stock price on companies listed on the JSX, rights issues have a significant effect on the stock trading volume on companies listed on the JSX, there is a significant correlation between stock price before and after the rights issue on companies listed in JSX, there is a significant correlation between volume of the stock trading before the rights issue and after that event. Data analysis used were descriptive statistics, simple linear regression analysis and paired t-test. Hypothesis testing was performed by using the Pearson correlation test with significance level of 5%. The results show that the right issue has a positive effect but not significant toward stock prices of companies listed in JSX, right issue has a negative effect and not significant toward the trading volume activity (TVA on companies listed in JSX.

  4. Transient computation fluid dynamics modeling of a single proton exchange membrane fuel cell with serpentine channel

    Science.gov (United States)

    Hu, Guilin; Fan, Jianren

    The proton exchange membrane fuel cell (PEMFC) has become a promising candidate for the power source of electrical vehicles because of its low pollution, low noise and especially fast startup and transient responses at low temperatures. A transient, three-dimensional, non-isothermal and single-phase mathematical model based on computation fluid dynamics has been developed to describe the transient process and the dynamic characteristics of a PEMFC with a serpentine fluid channel. The effects of water phase change and heat transfer, as well as electrochemical kinetics and multicomponent transport on the cell performance are taken into account simultaneously in this comprehensive model. The developed model was employed to simulate a single laboratory-scale PEMFC with an electrode area about 20 cm 2. The dynamic behavior of the characteristic parameters such as reactant concentration, pressure loss, temperature on the membrane surface of cathode side and current density during start-up process were computed and are discussed in detail. Furthermore, transient responses of the fuel cell characteristics during step changes and sinusoidal changes in the stoichiometric flow ratio of the cathode inlet stream, cathode inlet stream humidity and cell voltage are also studied and analyzed and interesting undershoot/overshoot behavior of some variables was found. It was also found that the startup and transient response time of a PEM fuel cell is of the order of a second, which is similar to the simulation results predicted by most models. The result is an important guide for the optimization of PEMFC designs and dynamic operation.

  5. Nitrogen-Coordinated Single Cobalt Atom Catalysts for Oxygen Reduction in Proton Exchange Membrane Fuel Cells.

    Science.gov (United States)

    Wang, Xiao Xia; Cullen, David A; Pan, Yung-Tin; Hwang, Sooyeon; Wang, Maoyu; Feng, Zhenxing; Wang, Jingyun; Engelhard, Mark H; Zhang, Hanguang; He, Yanghua; Shao, Yuyan; Su, Dong; More, Karren L; Spendelow, Jacob S; Wu, Gang

    2018-03-01

    Due to the Fenton reaction, the presence of Fe and peroxide in electrodes generates free radicals causing serious degradation of the organic ionomer and the membrane. Pt-free and Fe-free cathode catalysts therefore are urgently needed for durable and inexpensive proton exchange membrane fuel cells (PEMFCs). Herein, a high-performance nitrogen-coordinated single Co atom catalyst is derived from Co-doped metal-organic frameworks (MOFs) through a one-step thermal activation. Aberration-corrected electron microscopy combined with X-ray absorption spectroscopy virtually verifies the CoN 4 coordination at an atomic level in the catalysts. Through investigating effects of Co doping contents and thermal activation temperature, an atomically Co site dispersed catalyst with optimal chemical and structural properties has achieved respectable activity and stability for the oxygen reduction reaction (ORR) in challenging acidic media (e.g., half-wave potential of 0.80 V vs reversible hydrogen electrode (RHE). The performance is comparable to Fe-based catalysts and 60 mV lower than Pt/C -60 μg Pt cm -2 ). Fuel cell tests confirm that catalyst activity and stability can translate to high-performance cathodes in PEMFCs. The remarkably enhanced ORR performance is attributed to the presence of well-dispersed CoN 4 active sites embedded in 3D porous MOF-derived carbon particles, omitting any inactive Co aggregates. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. IMPLEMENTASI SINGLE MINUTE EXCHANGE OF DIES (SMED UNTUK OPTIMASI WAKTU CHANGEOVER MODEL PADA PRODUKSI PANEL TELEKOMUNIKASI

    Directory of Open Access Journals (Sweden)

    Ahmad Mulyana

    2017-06-01

    Full Text Available Sebagai salah satu perusahaan pembuat panel telekomunikasi dan panel elektrik, PT. Cometal dihadapkan pada tantangan waktu delivery yang kompetitif.  Permasalahannya perusahaan masih mengalami keterlambatan pengiriman produk ke konsumen akibat lamanya waktu changeover model yang menyebabkan downtime mesin punching pada proses produksi panel telekomunikasi. Untuk mengurangi lead time maka perlu diupayakan minimasi waste pada changeover model di mesin punching.  Tujuan penelitian ini adalah mengidentifikasi faktor penyebab tingginya waktu changeover model pada mesin punching dan melakukan improvement dengan metode SMED (single minute exchange of dies.  Penerapan metode SMED dilakukan dengan mengotimalkan aktifitas eksternal pada produksi panel telekomunikasi melalui koordinasi kegiatan Pengamatan dilakukan selama 30 hari menggunakan studi waktu sebelum dan sesudah implementasi SMED.  Penerapan konsep SMED dilakukan dengan  mengubah 15 aktifitas internal menjadi 5 aktifitas internal dan merekayasa alat bantu gauge tool untuk mengurangi downtime mesin.  Improvement yang diperoleh adalah berkurangnya waktu downtime mesin punching dari 44,90 jam menjadi 10,96 jam atau terjadi penurunan waktu setup sebesar 75, 59 persen.

  7. A single glycine-alanine exchange directs ligand specificity of the elephant progestin receptor.

    Directory of Open Access Journals (Sweden)

    Michael Wierer

    Full Text Available The primary gestagen of elephants is 5α-dihydroprogesterone (DHP, which is unlike all other mammals studied until now. The level of DHP in elephants equals that of progesterone in other mammals, and elephants are able to bind DHP with similar affinity to progesterone indicating a unique ligand-binding specificity of the elephant progestin receptor (PR. Using site-directed mutagenesis in combination with in vitro binding studies we here report that this change in specificity is due to a single glycine to alanine exchange at position 722 (G722A of PR, which specifically increases DHP affinity while not affecting binding of progesterone. By conducting molecular dynamics simulations comparing human and elephant PR ligand-binding domains (LBD, we observed that the alanine methyl group at position 722 is able to push the DHP A-ring into a position similar to progesterone. In the human PR, the DHP A-ring position is twisted towards helix 3 of PR thereby disturbing the hydrogen bond pattern around the C3-keto group, resulting in a lower binding affinity. Furthermore, we observed that the elephant PR ligand-binding pocket is more rigid than the human analogue, which probably explains the higher affinity towards both progesterone and DHP. Interestingly, the G722A substitution is not elephant-specific, rather it is also present in five independent lineages of mammalian evolution, suggesting a special role of the substitution for the development of distinct mammalian gestagen systems.

  8. The effectiveness of single minute exchange of dies for lean changeover process in printing industry

    Directory of Open Access Journals (Sweden)

    Indrawati Sri

    2018-01-01

    Full Text Available The changeover time is a factor that greatly affects the lean production implementation in industry with make to order system. Large product variations and unpredictable quantity of orders will trigger some kind of production wastes if changeover time is done in a longer time. One industry with make to order system is printing industry. In general, to produce several types of products such as books takes quite a long time because of long production changeover process. The general problem faced is the delay in book’s production completion. Based on this problem, changeover time reduction is needed to overcome the delay of book’s production completion using single minute exchanges of dies (SMED method. The SMED method is the method that separates the changeover activity into two, i.e. internal setup and external setup. The research shows that changeover time for printing workstation is 18 minutes 29 seconds, which consists of internal setup activities 14 minutes 37 seconds and external setup 4 minutes 33 seconds. By converting 45% of the internal setup activity into an external setup, then the setup time can be reduced. The initial setup activities performed when machine is stop, now can be done when the machine is running. In addition, a changeover process improvement also done using 5S method in workstation tools area so the internal setup time is reduced 46% becomes 7 minutes 59 seconds. Under these conditions, the printing industry can increase production by 2%.

  9. Gradient rotating outer volume excitation (GROOVE): A novel method for single-shot two-dimensional outer volume suppression.

    Science.gov (United States)

    Powell, Nathaniel J; Jang, Albert; Park, Jang-Yeon; Valette, Julien; Garwood, Michael; Marjańska, Małgorzata

    2015-01-01

    To introduce a new outer volume suppression (OVS) technique that uses a single pulse and rotating gradients to accomplish frequency-swept excitation. This new technique, which is called gradient rotating outer volume excitation (GROOVE), produces a circular or elliptical suppression band rather than suppressing the entire outer volume. Theoretical and k-space descriptions of GROOVE are provided. The properties of GROOVE were investigated with simulations, phantom, and human experiments performed using a 4T horizontal bore magnet equipped with a TEM coil. Similar suppression performance was obtained in phantom and human brain using GROOVE with circular and elliptical shapes. Simulations indicate that GROOVE requires less SAR and time than traditional OVS schemes, but traditional schemes provide a sharper transition zone and less residual signal. GROOVE represents a new way of performing OVS in which spins are excited temporally in space on a trajectory that can be tailored to fit the shape of the suppression region. In addition, GROOVE is capable of suppressing tailored regions of space with more flexibility and in a shorter period of time than conventional methods. GROOVE provides a fast, low SAR alternative to conventional OVS methods in some applications (e.g., scalp suppression). © 2014 Wiley Periodicals, Inc.

  10. Developing single-molecule TPM experiments for direct observation of successful RecA-mediated strand exchange reaction.

    Science.gov (United States)

    Fan, Hsiu-Fang; Cox, Michael M; Li, Hung-Wen

    2011-01-01

    RecA recombinases play a central role in homologous recombination. Once assembled on single-stranded (ss) DNA, RecA nucleoprotein filaments mediate the pairing of homologous DNA sequences and strand exchange processes. We have designed two experiments based on tethered particle motion (TPM) to investigate the fates of the invading and the outgoing strands during E. coli RecA-mediated pairing and strand exchange at the single-molecule level in the absence of force. TPM experiments measure the tethered bead Brownian motion indicative of the DNA tether length change resulting from RecA binding and dissociation. Experiments with beads labeled on either the invading strand or the outgoing strand showed that DNA pairing and strand exchange occurs successfully in the presence of either ATP or its non-hydrolyzable analog, ATPγS. The strand exchange rates and efficiencies are similar under both ATP and ATPγS conditions. In addition, the Brownian motion time-courses suggest that the strand exchange process progresses uni-directionally in the 5'-to-3' fashion, using a synapse segment with a wide and continuous size distribution.

  11. Comparison of bone volume measurements using conventional single and dual energy computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yung Kyoon; Park, Sang Hoon [Dept. of Radiology, Samsung Medical Center, Seoul (Korea, Republic of); Kim, Yon Min [Dept. of Radiotechnology, Wonkwang Health Science University, Iksan (Korea, Republic of)

    2017-06-15

    The study examines changes in calcium volume on born by comparing two figures; one is measured by dual energy computed tomography(DECT) followed by applying variation in monochromatic energy selection( keV), material decomposition(MD), and material suppressed iodine(MSI) analysis, and the other is measured by conventional single source computed tomography(CSCT). For this study, based on CSCT images taken by using human mimicked phantom, 70, 100, 140 keV and MSI, MD material calcium weighting( MCW) and MD material iodine weighting(MIW) of DECT were applied respectively. Then calculated calcium volume was converted to Agatston score for comparison. Volume of human mimicked phantom was in inverse proportion to keV. The volume decreased while keV increased(p<0.05). The most similar DECT volumes were reconstructed at 70 keV, the difference was showed 35.8±12.2 for rib, femur (16.1±24.1), pelvis(13.7±18.8), and spine(179.0±61.8). However, the volume of MSI was down for each organ; the volume of rib was 5.55%, femur(76.34%), pelvis(55.16%) and spine(87.58%). The volume of MSI decreased 55.9% for rib, femur(80.7%), pelvis(69.6%) and spine(54.2%) while MD MIW reduced for rib(83.51%), femur(87.68%), pelvis(86.64%), and spine(82.62%). With the results, the study found that outcomes were affected by the method which examiners employed. When using DECT, calcium volume of born dropped with keV increased. It also found that the most similar DECT images were reconstructed at 70 keV. The results of experiments implied that the users of MSI and MD should be cautious of errors as there are big differences in scores between those two methods.

  12. Evaluation Methodology. The Evaluation Exchange. Volume 11, Number 2, Summer 2005

    Science.gov (United States)

    Coffman, Julia, Ed.

    2005-01-01

    This is the third issue of "The Evaluation Exchange" devoted entirely to the theme of methodology, though every issue tries to identify new methodological choices, the instructive ways in which people have applied or combined different methods, and emerging methodological trends. For example, lately "theories of change" have gained almost…

  13. The influence of elastic subsystem on phase transitions in ferromagnets with competitive exchange and single-ion anisotropies

    International Nuclear Information System (INIS)

    Freedman, Yu.A.; Klevets, F.N.; Matunin, D.A.

    2006-01-01

    The influence of planar and bulk elastic interactions on the phase states of an ultrathin ferromagnetic film with anisotropic exchange interaction is investigated for different relationships among the material constants. It is shown that when the elastic interactions, with competing exchange and single-ion anisotropies, and the magnetic dipole interaction are taken into account, a cascade of phase transitions appears. Furthermore, taking the 'planar' elastic interaction into account leads to realization of an additional phase, with an easy axis in the film plane. This state is absent in the case of a bulk elastic subsystem

  14. Water softening by single-bowl ion exchange filter efficiency estimate and improvement

    OpenAIRE

    Kostygin, V. A.; Stolyarenko, G. S.; Kochetov, G. M.; Tugay, A. M.; Vashchenko, V. N.

    2014-01-01

    The article presents results of experimental investigations of the water softener in a laboratory installation of uninterruptible countercurrent ion exchange filter, which has a movable layer of ion exchange material. The installation provides for two simultaneous processes: counter ion sorption and regeneration of the sorbent with the processing capability of the sorbent in the regeneration zone by ultrasonic radiation.

  15. Ligand Exchange and 1H NMR Quantification of Single- and Mixed-Moiety Thiolated Ligand Shells on Gold Nanoparticles.

    Science.gov (United States)

    Smith, Ashley M; Millstone, Jill E

    2017-01-01

    The use of nanoparticles in biomedicine critically depends on their surface chemistry. For metal nanoparticles, a common way to tune this surface chemistry is through mass action ligand exchange, where ligand exchange can be used to expand the functionality of the resulting nanoparticle conjugates. Specifically, the quantity, identity, and arrangement of the molecules in the resulting ligand shell each can be tuned significantly. Here, we describe methods to exchange and quantify thiolated and non-thiolated ligands on gold nanoparticle surfaces. Importantly, these strategies allow the quantification of multiple ligand types within a single ligand shell, simultaneously providing ligand composition and ligand density information. These results are crucial for both designing and assigning structure-function relationships in bio-functionalized nanoparticles, and these methods can be applied to a broad range of nanoparticle cores and ligand types including peptides, small molecule drugs, and oligonucleotides.

  16. A Control Volume Model of Solute Transport in a Single Fracture

    Science.gov (United States)

    Kennedy, Christopher A.; Lennox, William C.

    1995-02-01

    A control volume model of solute transport through a single fracture in a porous matrix is developed. Application to problems of contaminant transport through fractured clay demonstrates several strong features of the method. The control volume approach inherently conserves mass and treats dispersivity at interfaces in a physically correct manner. By employing an upstream weighting scheme, based on the exact solution to the one-dimensional steady state advection-dispersion equation, the model proves to be more efficient than previous single-fracture models. The significance of matrix diffusion in the direction parallel to the fracture axis is investigated. For the transport of a nonreactive tracer through a 20-micrometer-wide fracture in clay material, analytical solutions based on one-dimensional matrix diffusion are erroneous for flow velocities of less than 1 m/day. The influence of boundary conditions on two-dimensional matrix diffusion is considered, and the clean-up of a contaminated fracture is simulated.

  17. Plasma exchange for paediatric kidney disease-indications and outcomes: a single-centre experience.

    Science.gov (United States)

    Reddy, Sudheer Kumar; Jahan, Afsana; Chaturvedi, Swasti; Agarwal, Indira

    2015-12-01

    Outcome data in paediatrics regarding the use of plasmapheresis for immunological kidney disease are scarce. We aimed to evaluate the role of plasmapheresis in children presenting with severe renal impairment secondary to immunological kidney diseases. A retrospective chart review of children admitted between January 2009 and August 2013 to the Paediatric Nephrology Unit, Christian Medical College, Vellore, India, and requiring plasma exchange was undertaken. Demographic and clinical data were studied and descriptive statistics applied for analysis. Sixteen children underwent plasmapheresis with a male:female ratio of 10:6 and a mean age of 10.2 years (range 5-15 years). Twelve children had atypical haemolytic uraemic syndrome, two had anti-glomerular basement disease and one each had lupus nephritis with neurological manifestation and anti-nuclear cytoplasmic antibody-associated vasculitis. The mean serum creatinine at presentation was 6.52 [interquartile range (IQR) 4.96-7.85] mg/dL with a mean eGFR of 43 (IQR 27.54-56.7) mL/min/1.73 m(2). Other presenting features included nephrotic range proteinuria (69%), gross haematuria (27%), hypertension (94%) and seizures (37.5%). All children received 1.5 times plasma volume plasmapheresis (mean 11 sessions, range 5-26), dialysis and immunosuppressive therapy. The mean duration of follow-up was 4 months (range 2-24 months) with a majority of the children (15/16, 93.75%) surviving acute illness. One child died of overwhelming sepsis and another was lost to follow-up. Of the survivors, eight had eGFR >60 mL/min/1.73 m(2), while eGFR was 15-60 mL/min/1.73 m(2) in the remaining six children. Eight children were still requiring antihypertensive medications and two were continuing peritoneal dialysis at the last follow-up. Thus early introduction of plasmapheresis along with other supportive therapy in immunological kidney disease may improve outcome.

  18. Complications of Impulse Generator Exchange Surgery for Deep Brain Stimulation: A Single-Center, Retrospective Study.

    Science.gov (United States)

    Helmers, Ann-Kristin; Lübbing, Isabel; Birkenfeld, Falk; Witt, Karsten; Synowitz, Michael; Mehdorn, Hubertus Maximilian; Falk, Daniela

    2018-05-01

    Nonrechargeable deep brain stimulation impulse generators (IGs) with low or empty battery status require surgical IG exchange several years after initial implantation. The aim of this study was to investigate complication rates after IG exchange surgery and identify risk factors. We retrospectively analyzed complications following IG exchange surgery from 2008 to 2015 in our department. Medical records of all patients who underwent IG exchange surgery were systematically reviewed. The shortest follow-up time was 19 months. From 2008 to 2015, 438 IGs were exchanged in 319 patients. Overall complication rate was 8.90%. Infection developed in 12 patients (2.74%). Six patients (1.37%) experienced local wound erosions. Hardware malfunctions were present in 11 patients (2.51%), and local hemorrhage was observed in 3 cases (0.68%). Repeated fixation of the IG was required in 2 patients (0.46%). Traction of the connecting cables necessitated surgical revision in 2 patients (0.46%). In 2 cases (0.46%), the IG was placed abdominally or exchanged for a smaller device owing to patient discomfort resulting from the initial positioning. One 80-year-old patient (0.23%) had severely worsening heart failure and died 4 days after IG exchange surgery. IG exchange surgery, although often considered a minor surgery, was associated with a complication rate of approximately 9% in our center. Patients and physicians should understand the complication rates associated with IG exchange surgery because this information might facilitate selection of a rechargeable IG. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. Single sweep three-dimensional carotid ultrasound: reproducibility in plaque and artery volume measurements.

    Science.gov (United States)

    Kalashyan, Hayrapet; Shuaib, Ashfaq; Gibson, Patrick H; Romanchuk, Helen; Saqqur, Maher; Khan, Khurshid; Osborne, Jonathon; Becher, Harald

    2014-02-01

    There is a need for non-invasive and accurate techniques for assessment of severity of atherosclerotic disease in the carotid arteries. Recently an automated single sweep three-dimensional ultrasound (3D US) technique became available. The aims of this study were to evaluate the feasibility and reproducibility of the automated single sweep method in a cohort of patients undergoing clinically indicated carotid ultrasound. Consecutive patients with a history of stroke or transient ischemic attack (TIA) and having a plaque in the internal carotid artery (ICA) were recruited for this study. Imaging was performed using a Philips iU 22 ultrasound system equipped with the single sweep volumetric transducer vL 13-5. Analysis was performed offline with software provided by the manufacturer. Two independent observers performed all measurements. Of 137 arteries studied (from 79 patients), plaque and artery volumes could be measured in 106 (77%). Reproducibility of plaque volume measurements was assessed in 82 arteries. Bland-Altman analysis demonstrated good inter-observer reproducibility with limits of agreement -0.06 to +0.07 ml. The mean percentage difference between two observers was 5.6% ± 6.0%. Reproducibility of artery volume measurement was assessed in 31 cases. Bland-Altman analysis demonstrated limits of agreement from -0.15 to +0.15 ml. The mean percentage difference was 6.4 ± 5.9%. The new automated single sweep 3D ultrasound is feasible in the majority of patients. Good reproducibility in plaque and artery volume measurements makes this technique suitable for serial assessment of carotid plaques. Copyright © 2014 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  20. Automated Hydrogen/Deuterium Exchange Electron Transfer Dissociation High Resolution Mass Spectrometry Measured at Single-Amide Resolution

    OpenAIRE

    Landgraf, Rachelle R.; Chalmers, Michael J.; Griffin, Patrick R.

    2011-01-01

    Hydrogen deuterium exchange mass spectrometry (HDX-MS) is a well established method for the measurement of solution-phase deuterium incorporation into proteins, which can provide insight into protein conformational mobility. However, most HDX measurements are constrained to regions of the protein where pepsin proteolysis allows detection at peptide resolution. Recently, single-amide resolution deuterium incorporation has been achieved by limiting gas-phase scrambling in the mass spectrometer....

  1. Spin Quantum Tunneling via Entangled States in a Dimer of Exchange-Coupled Single-Molecule Magnets

    Science.gov (United States)

    Tiron, R.; Wernsdorfer, W.; Foguet-Albiol, D.; Aliaga-Alcalde, N.; Christou, G.

    2003-11-01

    A new family of supramolecular, antiferromagnetically exchange-coupled dimers of single-molecule magnets (SMMs) has recently been reported. Each SMM acts as a bias on its neighbor, shifting the quantum tunneling resonances of the individual SMMs. Hysteresis loop measurements on a single crystal of SMM dimers have now established quantum tunneling of the magnetization via entangled states of the dimer. This shows that the dimer really does behave as a quantum mechanically coupled dimer, and also allows the measurement of the longitudinal and transverse superexchange coupling constants.

  2. [Peribulbar anesthesia: efficacy of a single injection with a limited local anesthetic volume].

    Science.gov (United States)

    Clausel, H; Touffet, L; Havaux, M; Lamard, M; Savean, J; Cochener, B; Arvieux, C; Gueret, G

    2008-10-01

    Cataract surgery can be performed with peribulbar anesthesia. The classical technique consists of two injections of local anesthetics. The purpose of our study was to assess peribulbar anesthesia with a single injection and a limited volume of local anesthetics. After local ethics committee agreement and oral consent, patients scheduled for cataract surgery using peribulbar anesthesia were prospectively included. The lower temporal puncture was performed with a peribulbar needle with propofol sedation. The mixture of local anesthetics was administered with tactile control of orbital pressure. The puncture was followed by a 10-min compression of the ocular globe. Akinesia, analgesia, complications, and surgical conditions were noted. A total of 101 successive patients were included. We administered 1.2 mg/kg of propofol. The volume of local anesthetics administered was 5.0 +/- 0.9 ml. Ninety patients had akinesia at 10 min and 6.7% moderate chemosis. No puncture complication occurred. At the end of surgery, the pain noted by the patients was 0.4 +/- 2.1 out of 100 (range, 0-10). Surgical conditions were good for all patients. Peribulbar anesthesia performed with a single injection and a limited volume of local anesthetics allows cataract surgery in good conditions for the surgeon with very good analgesia for the patient.

  3. Visceral adipose tissue area measurement at a single level: can it represent visceral adipose tissue volume?

    Science.gov (United States)

    Noumura, Yusuke; Kamishima, Tamotsu; Sutherland, Kenneth; Nishimura, Hideho

    2017-08-01

    Measurement of visceral adipose tissue (VAT) needs to be accurate and sensitive to change for risk monitoring. The purpose of this study is to determine the CT slice location where VAT area can best reflect changes in VAT volume and body weight. 60 plain abdominal CT images from 30 males [mean age (range) 51 (41-68) years, mean body weight (range) 71.1 (101.9-50.9) kg] who underwent workplace screenings twice within a 1-year interval were evaluated. Automatically calculated and manually corrected areas of the VAT of various scan levels using "freeform curve" region of interest on CT were recorded and compared with body weight changes. The strongest correlations of VAT area with VAT volume and body weight changes were shown in a slice 3 cm above the lower margin of L3 with r values of 0.853 and 0.902, respectively. VAT area measurement at a single level 3 cm above the lower margin of the L3 vertebra is feasible and can reflect changes in VAT volume and body weight. Advances in knowledge: As VAT area at a CT slice 3cm above the lower margin of L3 can best reflect interval changes in VAT volume and body weight, VAT area measurement should be selected at this location.

  4. Retrofitting of heat exchanger networks involving streams with variable heat capacity: Application of single and multi-objective optimization

    International Nuclear Information System (INIS)

    Sreepathi, Bhargava Krishna; Rangaiah, G.P.

    2015-01-01

    Heat exchanger network (HEN) retrofitting improves the energy efficiency of the current process by reducing external utilities. In this work, HEN retrofitting involving streams having variable heat capacity is studied. For this, enthalpy values of a stream are fitted to a continuous cubic polynomial instead of a stepwise approach employed in the previous studies [1,2]. The former methodology is closer to reality as enthalpy or heat capacity changes gradually instead of step changes. Using the polynomial fitting formulation, single objective optimization (SOO) and multi-objective optimization (MOO) of a HEN retrofit problem are investigated. The results obtained show an improvement in the utility savings, and MOO provides many Pareto-optimal solutions to choose from. Also, Pareto-optimal solutions involving area addition in existing heat exchangers only (but no new exchangers and no structural modifications) are found and provided for comparison with those involving new exchangers and structural modifications as well. - Highlights: • HEN retrofitting involving streams with variable heat capacities is studied. • A continuous approach to handle variable heat capacity is proposed and tested. • Better and practical solutions are obtained for HEN retrofitting in process plants. • Pareto-optimal solutions provide many alternate choices for HEN retrofitting

  5. Volume reflection and channeling of ultrarelativistic protons in germanium bent single crystals

    Directory of Open Access Journals (Sweden)

    S. Bellucci

    2016-12-01

    Full Text Available The paper is devoted to the investigation of volume reflection and channeling processes of ultrarelativistic positive charged particles moving in germanium single crystals. We demonstrate that the choice of atomic potential on the basis of the Hartree-Fock method and the correct choice of the Debye temperature allow us to describe the above mentioned processes in a good agreement with the recent experiments. Moreover, the universal form of equations for volume reflection presented in the paper gives a true description of the process at a wide range of particle energies. Standing on this study we make predictions for the mean angle reflection (as a function of the bending radius of positive and negative particles for germanium (110 and (111 crystallographic planes.

  6. Single-Crystal-to-Single-Crystal Anion Exchange in a Gadolinium MOF: Incorporation of POMs and [AuCl4]−

    Directory of Open Access Journals (Sweden)

    Javier López-Cabrelles

    2016-04-01

    Full Text Available The encapsulation of functional molecules inside porous coordination polymers (also known as metal-organic frameworks, MOFs has become of great interest in recent years at the field of multifunctional materials. In this article, we present a study of the effects of size and charge in the anion exchange process of a Gd based MOF, involving molecular species like polyoxometalates (POMs, and [AuCl4]−. This post-synthetic modification has been characterized by IR, EDAX, and single crystal diffraction, which have provided unequivocal evidence of the location of the anion molecules in the framework.

  7. A novel algorithm for demand-control of a single-room ventilation unit with a rotary heat exchanger

    DEFF Research Database (Denmark)

    Smith, Kevin Michael; Jansen, Anders Lund; Svendsen, Svend

    in the indoor environment. Based on these values, a demand-control algorithm varies fan speeds to change airflow rates and varies the rotational speed of the heat exchanger to modulate heat and moisture recovery. The algorithm varies airflow rates to provide free cooling and limit CO2 concentrations and varies...... with heat recovery in individual rooms. This provides a unique opportunity to meet the demands of each room with an appropriate ventilation rate, supply temperature and drying capacity. In prior publications, the authors described the development of a single-room ventilation unit with a rotary heat...... exchanger, which is commercially available in Denmark. The unit includes temperature sensors at the inlet and outlet of the supply and exhaust airflows. At the exhaust inlet, a relative humidity sensor is standard and a CO2 sensor is optional. Together these sensors detect thermal comfort and air quality...

  8. How much diversification potential is there in a single market? Evidence from the Australian Stock Exchange

    OpenAIRE

    Yang, Libin; Rea, William; Rea, Alethea

    2015-01-01

    We present four methods of assessing the diversification potential within a stock market, two of these are based on principal component analysis. They were applied to the Australian stock exchange for the years 2000 to 2014 and all show a consistent picture. The potential for diversification declined almost monotonically in the three years prior to the 2008 financial crisis. On one of the measures the diversification potential declined even further in the 2011 European debt crisis and the Ame...

  9. Single interval longwave radiation scheme based on the net exchanged rate decomposition with bracketing

    Czech Academy of Sciences Publication Activity Database

    Geleyn, J.- F.; Mašek, Jan; Brožková, Radmila; Kuma, P.; Degrauwe, D.; Hello, G.; Pristov, N.

    2017-01-01

    Roč. 143, č. 704 (2017), s. 1313-1335 ISSN 0035-9009 R&D Projects: GA MŠk(CZ) LO1415 Institutional support: RVO:86652079 Keywords : numerical weather prediction * climate models * clouds * parameterization * atmospheres * formulation * absorption * scattering * accurate * database * longwave radiative transfer * broadband approach * idealized optical paths * net exchanged rate decomposition * bracketing * selective intermittency Subject RIV: DG - Athmosphere Sciences, Meteorology OBOR OECD: Meteorology and atmospheric sciences Impact factor: 3.444, year: 2016

  10. Simplified models of the symmetric single-pass parallel-plate counterflow heat exchanger: a tutorial.

    Science.gov (United States)

    Pickard, William F; Abraham-Shrauner, Barbara

    2018-03-01

    The heat exchanger is important in practical thermal processes, especially those of (i) the molten-salt storage schemes, (ii) compressed air energy storage schemes and (iii) other load-shifting thermal storage presumed to undergird a Smart Grid. Such devices, although central to the utilization of energy from sustainable (but intermittent) renewable sources, will be unfamiliar to many scientists, who nevertheless need a working knowledge of them. This tutorial paper provides a largely self-contained conceptual introduction for such persons. It begins by modelling a novel quantized exchanger, impractical as a device, but useful for comprehending the underlying thermophysics. It then reviews the one-dimensional steady-state idealization which demonstrates that effectiveness of heat transfer increases monotonically with (device length)/(device throughput). Next, it presents a two-dimensional steady-state idealization for plug flow and from it derives a novel formula for effectiveness of transfer; this formula is then shown to agree well with a finite-difference time-domain solution of the two-dimensional idealization under Hagen-Poiseuille flow. These results are consistent with a conclusion that effectiveness of heat exchange can approach unity, but may involve unwelcome trade-offs among device cost, size and throughput.

  11. Gradient ROtating Outer Volume Excitation (GROOVE): A Novel Method for Single-Shot 2-D OVS

    Science.gov (United States)

    Powell, Nathaniel J.; Jang, Albert; Park, Jang-Yeon; Valette, Julien; Garwood, Michael; Marjańska, Małgorzata

    2014-01-01

    Purpose A new outer volume suppression (OVS) technique is introduced that uses a single pulse and rotating gradients to accomplish frequency-swept excitation. This new technique, which is called Gradient ROtating Outer Volume Excitation (GROOVE), produces a circular or elliptical suppression band rather than suppressing the entire outer volume. Methods Theoretical and k-space descriptions of GROOVE are provided. The properties of GROOVE were investigated with simulations, phantom, and human experiments performed using a 4 T horizontal bore magnet equipped with a TEM coil. Results Similar suppression performance was obtained in phantom and human brain using GROOVE with circular and elliptical shapes. Simulations indicate that GROOVE requires less SAR and time than traditional OVS schemes, but traditional schemes provide a sharper transition zone and less residual signal. Conclusion GROOVE represents a new way of performing OVS in which spins are excited temporally in space on a trajectory which can be tailored to fit the shape of the suppression region. In addition, GROOVE is capable of suppressing tailored regions of space with more flexibility and in a shorter period of time than conventional methods. GROOVE provides a fast, low SAR alternative to conventional OVS methods in some applications (e.g., scalp suppression). PMID:24478130

  12. Experimental single photon exchange along a space link of 7000 km

    DEFF Research Database (Denmark)

    Dequal, Daniele; Vallone, Giuseppe; Bacco, Davide

    2015-01-01

    at the Matera Laser Ranging Observatory. The single photon transmitter was realized by exploiting the corner cube retro-reflectors mounted on the LAGEOS-2 satellite. Long duration of data collection is possible with such altitude, up to 43 minutes in a single passage. The mean number of photons per pulse (µsat...

  13. Single-well and inter-well dual-tracer test design for quantifying phase volumes and interface areas in subsurface flow and transport systems

    Science.gov (United States)

    Ghergut, I.; Behrens, H.; Licha, T.; Maier, F.; Nottebohm, M.; Schaffer, M.; Sauter, M.

    2012-04-01

    Technology-relevant georeservoirs in the realm of energy production (such as: spent-radionuclide repositories, gas-storage, geothermal, as well as CCS candidate reservoirs) contain mobile and immobile fluid regions, and often also different fluid and solid phases. The lifetime of a particular reservoir (from a hydraulic, thermal, geomechanical and/or hydrogeochemical point of view) depends on the volumes and/or interface areas of some of these regions and/or phases. Mostly, their lifetime-effective values cannot be measured by geophysical and hydraulic methods. Since they essentially relate to fluid-based transport processes, attempting to measure them by tracer tests is a sensible endeavour. However, in designing and dimensioning such tracer tests, one should keep in mind that not every tracer test is sensitive w. r. to every fluid transport parameter. A certain complementarity exists, w. r. to parameter sensitivity, between single-well and inter-well methods, between equilibrium and kinetic exchange processes, between volume and area parameters. Mobile-fluid volumes can be measured from inter-well conservative-tracer tests, whereas single-well push-pull tests are generally insensitive w. r. to mobile-fluid volumes. Immobile-fluid volumes, in single-phase systems, are rather difficult to measure, by either kind of test. Different-phase volumes can be determined from inter-well tests using partitioning tracers at equilibrium exchange between phases; whereas single-well tracer push-pull tests are rather insensitive w. r. to tracer exchange processes at equilibrium. Im-/mobile fluid, or inter-phase interface areas can be determined from single-well tracer push-pull tests relying on kinetic exchange processes between compartments or phases. Single-well tests are often believed to be more sensitive w. r. to such processes than w. r. to advective-dispersive processes, and than inter-well tests. Inter-well tests are not physically insensitive w. r. to kinetic exchange

  14. Novel single-layer gas diffusion layer based on PTFE/carbon black composite for proton exchange membrane fuel cell

    Energy Technology Data Exchange (ETDEWEB)

    Chen-Yang, Y.W.; Hung, T.F.; Yang, F.L. [Department of Chemistry and Center for Nanotechnology, Chung Yuan Christian University, Chung-Li 32023 (China); Huang, J. [Yeu Ming Tai Chemical Industrial Co., Ltd, Taichung 40768 (China)

    2007-11-08

    A series of poly(tetrafluoroethylene)/carbon black composite-based single-layer gas diffusion layers (PTFE/CB-GDLs) for proton exchange membrane fuel cell (PEMFC) was successfully prepared from carbon black and un-sintered PTFE, which included powder resin and colloidal dispersion, by a simple inexpensive method. The scanning electron micrographs of PTFE/CB-GDLs indicated that the PTFE resins were homogeneously dispersed in the carbon black matrix and showed a microporous layer (MPL)-like structure. The as-prepared PTFE/CB-GDLs exhibited good mechanical property, high gas permeability, and sufficient water repellency. The best current density obtained from the PEMFC with the single-layer PTFE/CB-GDL was 1.27 and 0.42 A cm{sup -2} for H{sub 2}/O{sub 2} and H{sub 2}/air system, respectively. (author)

  15. Observations of Recent Arctic Sea Ice Volume Loss and Its Impact on Ocean-Atmosphere Energy Exchange and Ice Production

    Science.gov (United States)

    Kurtz, N. T.; Markus, T.; Farrell, S. L.; Worthen, D. L.; Boisvert, L. N.

    2011-01-01

    Using recently developed techniques we estimate snow and sea ice thickness distributions for the Arctic basin through the combination of freeboard data from the Ice, Cloud, and land Elevation Satellite (ICESat) and a snow depth model. These data are used with meteorological data and a thermodynamic sea ice model to calculate ocean-atmosphere heat exchange and ice volume production during the 2003-2008 fall and winter seasons. The calculated heat fluxes and ice growth rates are in agreement with previous observations over multiyear ice. In this study, we calculate heat fluxes and ice growth rates for the full distribution of ice thicknesses covering the Arctic basin and determine the impact of ice thickness change on the calculated values. Thinning of the sea ice is observed which greatly increases the 2005-2007 fall period ocean-atmosphere heat fluxes compared to those observed in 2003. Although there was also a decline in sea ice thickness for the winter periods, the winter time heat flux was found to be less impacted by the observed changes in ice thickness. A large increase in the net Arctic ocean-atmosphere heat output is also observed in the fall periods due to changes in the areal coverage of sea ice. The anomalously low sea ice coverage in 2007 led to a net ocean-atmosphere heat output approximately 3 times greater than was observed in previous years and suggests that sea ice losses are now playing a role in increasing surface air temperatures in the Arctic.

  16. Protein hydrogen exchange measured at single-residue resolution by electron transfer dissociation mass spectrometry

    DEFF Research Database (Denmark)

    Rand, Kasper D; Zehl, Martin; Jensen, Ole Nørregaard

    2009-01-01

    Because of unparalleled sensitivity and tolerance to protein size, mass spectrometry (MS) has become a popular method for measuring the solution hydrogen (1H/2H) exchange (HX) of biologically relevant protein states. While incorporated deuterium can be localized to different regions by pepsin...... proteolysis of the labeled protein, the assignment of deuteriums to individual residues is typically not obtained, thereby limiting a detailed understanding of HX and the dynamics of protein structure. Here we use gas-phase fragmentation of peptic peptides by electron transfer dissociation (ETD) to measure...... the HX of individual amide linkages in the amyloidogenic protein beta2-microglobulin. A comparison of the deuterium levels of 60 individual backbone amides of beta2-microglobulin measured by HX-ETD-MS analysis to the corresponding values measured by NMR spectroscopy shows an excellent correlation...

  17. Single x-ray absorptiometry method for the quantitative mammographic measure of fibroglandular tissue volume

    International Nuclear Information System (INIS)

    Malkov, Serghei; Wang, Jeff; Kerlikowske, Karla; Cummings, Steven R.; Shepherd, John A.

    2009-01-01

    Purpose: This study describes the design and characteristics of a highly accurate, precise, and automated single-energy method to quantify percent fibroglandular tissue volume (%FGV) and fibroglandular tissue volume (FGV) using digital screening mammography. Methods: The method uses a breast tissue-equivalent phantom in the unused portion of the mammogram as a reference to estimate breast composition. The phantom is used to calculate breast thickness and composition for each image regardless of x-ray technique or the presence of paddle tilt. The phantom adheres to the top of the mammographic compression paddle and stays in place for both craniocaudal and mediolateral oblique screening views. We describe the automated method to identify the phantom and paddle orientation with a three-dimensional reconstruction least-squares technique. A series of test phantoms, with a breast thickness range of 0.5-8 cm and a %FGV of 0%-100%, were made to test the accuracy and precision of the technique. Results: Using test phantoms, the estimated repeatability standard deviation equaled 2%, with a ±2% accuracy for the entire thickness and density ranges. Without correction, paddle tilt was found to create large errors in the measured density values of up to 7%/mm difference from actual breast thickness. This new density measurement is stable over time, with no significant drifts in calibration noted during a four-month period. Comparisons of %FGV to mammographic percent density and left to right breast %FGV were highly correlated (r=0.83 and 0.94, respectively). Conclusions: An automated method for quantifying fibroglandular tissue volume has been developed. It exhibited good accuracy and precision for a broad range of breast thicknesses, paddle tilt angles, and %FGV values. Clinical testing showed high correlation to mammographic density and between left and right breasts.

  18. Automated Hydrogen/Deuterium Exchange Electron Transfer Dissociation High Resolution Mass Spectrometry Measured at Single-Amide Resolution

    Science.gov (United States)

    Landgraf, Rachelle R.; Chalmers, Michael J.; Griffin, Patrick R.

    2012-02-01

    Hydrogen deuterium exchange mass spectrometry (HDX-MS) is a well established method for the measurement of solution-phase deuterium incorporation into proteins, which can provide insight into protein conformational mobility. However, most HDX measurements are constrained to regions of the protein where pepsin proteolysis allows detection at peptide resolution. Recently, single-amide resolution deuterium incorporation has been achieved by limiting gas-phase scrambling in the mass spectrometer. This was accomplished by employing a combination of soft ionization and desolvation conditions coupled with the radical-driven fragmentation technique electron transfer dissociation (ETD). Here, a hybrid LTQ-Orbitrap XL is systematically evaluated for its utility in providing single-amide deuterium incorporation for differential HDX analysis of a nuclear receptor upon binding small molecule ligands. We are able to show that instrumental parameters can be optimized to minimize scrambling and can be incorporated into an established and fully automated HDX platform making differential single-amide HDX possible for bottom-up analysis of complex systems. We have applied this system to determine differential single amide resolution HDX data for the peroxizome proliferator activated receptor bound with two ligands of interest.

  19. Measuring surface-area-to-volume ratios in soft porous materials using laser-polarized xenon interphase exchange nuclear magnetic resonance

    Science.gov (United States)

    Butler, J. P.; Mair, R. W.; Hoffmann, D.; Hrovat, M. I.; Rogers, R. A.; Topulos, G. P.; Walsworth, R. L.; Patz, S.

    2002-01-01

    We demonstrate a minimally invasive nuclear magnetic resonance (NMR) technique that enables determination of the surface-area-to-volume ratio (S/V) of soft porous materials from measurements of the diffusive exchange of laser-polarized 129Xe between gas in the pore space and 129Xe dissolved in the solid phase. We apply this NMR technique to porous polymer samples and find approximate agreement with destructive stereological measurements of S/V obtained with optical confocal microscopy. Potential applications of laser-polarized xenon interphase exchange NMR include measurements of in vivo lung function in humans and characterization of gas chromatography columns.

  20. Organization of DNA partners and strand exchange mechanisms during Flp site-specific recombination analyzed by difference topology, single molecule FRET and single molecule TPM.

    Science.gov (United States)

    Ma, Chien-Hui; Liu, Yen-Ting; Savva, Christos G; Rowley, Paul A; Cannon, Brian; Fan, Hsiu-Fang; Russell, Rick; Holzenburg, Andreas; Jayaram, Makkuni

    2014-02-20

    Flp site-specific recombination between two target sites (FRTs) harboring non-homology within the strand exchange region does not yield stable recombinant products. In negatively supercoiled plasmids containing head-to-tail sites, the reaction produces a series of knots with odd-numbered crossings. When the sites are in head-to-head orientation, the knot products contain even-numbered crossings. Both types of knots retain parental DNA configuration. By carrying out Flp recombination after first assembling the topologically well defined Tn3 resolvase synapse, it is possible to determine whether these knots arise by a processive or a dissociative mechanism. The nearly exclusive products from head-to-head and head-to-tail oriented "non-homologous" FRT partners are a 4-noded knot and a 5-noded knot, respectively. The corresponding products from a pair of native (homologous) FRT sites are a 3-noded knot and a 4-noded catenane, respectively. These results are consistent with non-homology-induced two rounds of dissociative recombination by Flp, the first to generate reciprocal recombinants containing non-complementary base pairs and the second to produce parental molecules with restored base pairing. Single molecule fluorescence resonance energy transfer (smFRET) analysis of geometrically restricted FRTs, together with single molecule tethered particle motion (smTPM) assays of unconstrained FRTs, suggests that the sites are preferentially synapsed in an anti-parallel fashion. This selectivity in synapse geometry occurs prior to the chemical steps of recombination, signifying early commitment to a productive reaction path. The cumulative topological, smFRET and smTPM results have implications for the relative orientation of DNA partners and the directionality of strand exchange during recombination mediated by tyrosine site-specific recombinases. Copyright © 2013. Published by Elsevier Ltd.

  1. Deuteron NMR resolved mesogen vs. crosslinker molecular order and reorientational exchange in liquid single crystal elastomers

    Czech Academy of Sciences Publication Activity Database

    Milavec, J.; Domenici, V.; Zupančič, B.; Rešetič, A.; Bubnov, Alexej; Zalar, B.

    2016-01-01

    Roč. 18, č. 5 (2016), s. 4071-4077 ISSN 1463-9076 R&D Projects: GA ČR GA15-02843S; GA MŠk(CZ) LD14007 Grant - others:EU - ICT(XE) COST Action IC1208 Institutional support: RVO:68378271 Keywords : liquid single crystal elastomer * NMR * liquid crystal * molecular order * monomers Subject RIV: JJ - Other Materials Impact factor: 4.123, year: 2016

  2. When a single hole aligns several spins: Double exchange in organic systems

    Energy Technology Data Exchange (ETDEWEB)

    Trinquier, Georges; Chilkuri, Vijay Gopal; Malrieu, Jean-Paul [Laboratoire de Chimie et Physique Quantiques, CNRS, UMR 5626, IRSAMC, Université Paul-Sabatier, 118 Rte de Narbonne, 31062 Toulouse Cedex (France)

    2014-05-28

    The double exchange is a well-known and technically important phenomenon in solid state physics. Ionizing a system composed of two antiferromagnetically coupled high-spin units, the ground state of which is a singlet state, may actually produce a high-spin ground state. This work illustrates the possible occurrence of such a phenomenon in organic chemistry. The here-considered high-spin units are triangulenes, the ground state of which is a triplet. Bridging two of them through a benzene ring produces a molecular architecture of singlet ground state. A careful exploitation of a series of unrestricted density functional calculations enables one to avoid spin contamination in the treatment of the doublet states and shows that under ionization the system becomes of quartet multiplicity in its ground state. The possibility to align more than three spins from conjugated hydrocarbon polyradicals is explored, considering partially hydrogenated triangulenes. A dramatic example shows that ionization of a singlet ground state molecule may generate a decuplet.

  3. Pulmonary gas exchange impairment following tourniquet deflation: a prospective, single-blind clinical trial.

    Science.gov (United States)

    Lin, Lina; Wang, Liangrong; Bai, Yu; Zheng, Liupu; Zhao, Xiyue; Xiong, Xiangqing; Jin, Lida; Ji, Wei; Wang, Wantie

    2010-06-09

    The tourniquet has been considered as a recognized cause of limb ischemia/reperfusion injury in orthopedic surgery resulting in a transient neutrophil, monocyte activation, and enhanced neutrophil transendothelial migration with potential remote tissue injury. This study investigated the effect of unilateral tourniquet application within a safe time limit on pulmonary function and the roles of lipid peroxidation and systemic inflammatory response. Thirty patients undergoing unilateral lower extremity surgery with or without tourniquet were equally divided into a control group with no tourniquet (Group C) and a tourniquet (Group T). Arterial partial pressure of oxygen (P(a)O(2)), arterial-alveolar oxygen tension ratio (a/A ratio), alveolar-arterial oxygen difference (A-aDO(2)) and respiratory index, plasma malondialdehyde, serum interleukin (IL) -6 and IL-8 levels were measured immediately before and 1 hour after tourniquet inflation/operation beginning, 0.5, 2, 6, and 24 hours after tourniquet deflation/operation ending. The results represented no significant changes in Group C with regard to either blood gas variables or levels of circulating mediators, while blood gas variable changes of greater A-aDO(2) and respiratory index and lower PaO2 and a/A ratio were shown at 6 hours following tourniquet deflation. The levels of malondialdehyde, IL-6, and IL-8 were increased over baseline values from 2 to 24 hours following tourniquet deflation in Group T. We concluded that tourniquet application within a safe time limit may cause pulmonary gas exchange impairment several hours after tourniquet deflation, where lipid peroxidation and systemic inflammatory response may be involved. Copyright 2010, SLACK Incorporated.

  4. Exergy analysis of single effect absorption refrigeration systems: The heat exchange aspect

    International Nuclear Information System (INIS)

    Joybari, Mahmood Mastani; Haghighat, Fariborz

    2016-01-01

    Highlights: • Exergy analysis of LiBr/H 2 O absorption systems with identical COP was carried out. • Exergy destruction rank: absorber followed by generator, condenser and evaporator. • Lower heat source and chilled water inlet temperature reduced exergy destruction. • Higher cooling water inlet temperature reduced exergy destruction. • Lower HTF mass flow rate increased exergy efficiency even for fixed system COP. - Abstract: The main limitation of conventional energy analysis for the thermal performance of energy systems is that this approach does not consider the quality of energy. On the other hand, exergy analysis not only provides information about the systems performance, but also it can specify the locations and magnitudes of losses. A number of studies investigated the effect of parameters such as the component temperature, and heat transfer fluid (HTF) temperature and mass flow rate on the exergetic performance of the same absorption refrigeration system; thus, reported different coefficient of performance (COP) values. However, in this study, the system COP was considered to remain constant during the investigation. This means comparing systems with different heat exchanger designs (based on HTF mass flow rate and temperature) having the same COP value. The effect of HTF mass flow rate and inlet temperature of the cooling water, chilled water and heat source on the outlet specific exergy and exergy destruction rate of each component was investigated. It was found that the lower HTF mass flow rate decreased exergy destruction of the corresponding component. Moreover, the lower temperature of heat source and chilled water inlet increased the system exergetic efficiency. That was also the case for the higher cooling water inlet temperature. Based on the analysis, since the absorber and condenser accounted for a large portion of the total exergy destruction, cooling tower modification with lower cooling water mass flow rate is recommended

  5. Single-molecule imaging of platinum ligand exchange reaction reveals reactivity distribution.

    Science.gov (United States)

    Esfandiari, N Melody; Wang, Yong; Bass, Jonathan Y; Cornell, Trevor P; Otte, Douglas A L; Cheng, Ming H; Hemminger, John C; McIntire, Theresa M; Mandelshtam, Vladimir A; Blum, Suzanne A

    2010-11-03

    Single-molecule fluorescence microscopy provided information about the real-time distribution of chemical reactivity on silicon oxide supports at the solution-surface interface, at a level of detail which would be unavailable from a traditional ensemble technique or from a technique that imaged the static physical properties of the surface. Chemical reactions on the surface were found to be uncorrelated; that is, the chemical reaction of one metal complex did not influence the location of a future chemical reaction of another metal complex.

  6. High-throughput investigation of single and binary protein adsorption isotherms in anion exchange chromatography employing multivariate analysis.

    Science.gov (United States)

    Field, Nicholas; Konstantinidis, Spyridon; Velayudhan, Ajoy

    2017-08-11

    The combination of multi-well plates and automated liquid handling is well suited to the rapid measurement of the adsorption isotherms of proteins. Here, single and binary adsorption isotherms are reported for BSA, ovalbumin and conalbumin on a strong anion exchanger over a range of pH and salt levels. The impact of the main experimental factors at play on the accuracy and precision of the adsorbed protein concentrations is quantified theoretically and experimentally. In addition to the standard measurement of liquid concentrations before and after adsorption, the amounts eluted from the wells are measured directly. This additional measurement corroborates the calculation based on liquid concentration data, and improves precision especially under conditions of weak or moderate interaction strength. The traditional measurement of multicomponent isotherms is limited by the speed of HPLC analysis; this analytical bottleneck is alleviated by careful multivariate analysis of UV spectra. Copyright © 2017. Published by Elsevier B.V.

  7. Targeted Integration of Single-Copy Transgenes in Drosophila melanogaster Tissue-Culture Cells Using Recombination-Mediated Cassette Exchange.

    Science.gov (United States)

    Manivannan, Sathiya N; Jacobsen, Thomas L; Lyon, Peter; Selvaraj, Bhavani; Halpin, Peter; Simcox, Amanda

    2015-12-01

    Transfection of transgenes into Drosophila cultured cells is a standard approach for studying gene function. However, the number of transgenes present in the cell following transient transfection or stable random integration varies, and the resulting differences in expression level affect interpretation. Here we developed a system for Drosophila cell lines that allows selection of cells with a single-copy transgene inserted at a specific genomic site using recombination-mediated cassette exchange (RMCE). We used the φC31 integrase and its target sites attP and attB for RMCE. Cell lines with an attP-flanked genomic cassette were transfected with donor plasmids containing a transgene of interest (UAS-x), a dihydrofolate reductase (UAS-DHFR) gene flanked by attB sequences, and a thymidine kinase (UAS-TK) gene in the plasmid backbone outside the attB sequences. In cells undergoing RMCE, UAS-x and UAS-DHFR were exchanged for the attP-flanked genomic cassette, and UAS-TK was excluded. These cells were selected using methotrexate, which requires DHFR expression, and ganciclovir, which causes death in cells expressing TK. Pure populations of cells with one copy of a stably integrated transgene were efficiently selected by cloning or mass culture in ∼6 weeks. Our results show that RMCE avoids the problems associated with current methods, where transgene number is not controlled, and facilitates the rapid generation of Drosophila cell lines in which expression from a single transgene can be studied. Copyright © 2015 by the Genetics Society of America.

  8. Tidal Volume Single Breath Washout of Two Tracer Gases - A Practical and Promising Lung Function Test

    Science.gov (United States)

    Singer, Florian; Stern, Georgette; Thamrin, Cindy; Fuchs, Oliver; Riedel, Thomas; Gustafsson, Per; Frey, Urs; Latzin, Philipp

    2011-01-01

    Background Small airway disease frequently occurs in chronic lung diseases and may cause ventilation inhomogeneity (VI), which can be assessed by washout tests of inert tracer gas. Using two tracer gases with unequal molar mass (MM) and diffusivity increases specificity for VI in different lung zones. Currently washout tests are underutilised due to the time and effort required for measurements. The aim of this study was to develop and validate a simple technique for a new tidal single breath washout test (SBW) of sulfur hexafluoride (SF6) and helium (He) using an ultrasonic flowmeter (USFM). Methods The tracer gas mixture contained 5% SF6 and 26.3% He, had similar total MM as air, and was applied for a single tidal breath in 13 healthy adults. The USFM measured MM, which was then plotted against expired volume. USFM and mass spectrometer signals were compared in six subjects performing three SBW. Repeatability and reproducibility of SBW, i.e., area under the MM curve (AUC), were determined in seven subjects performing three SBW 24 hours apart. Results USFM reliably measured MM during all SBW tests (n = 60). MM from USFM reflected SF6 and He washout patterns measured by mass spectrometer. USFM signals were highly associated with mass spectrometer signals, e.g., for MM, linear regression r-squared was 0.98. Intra-subject coefficient of variation of AUC was 6.8%, and coefficient of repeatability was 11.8%. Conclusion The USFM accurately measured relative changes in SF6 and He washout. SBW tests were repeatable and reproducible in healthy adults. We have developed a fast, reliable, and straightforward USFM based SBW method, which provides valid information on SF6 and He washout patterns during tidal breathing. PMID:21423739

  9. Laue diffraction: The key to neutron crystallography from submillimetric-volume single crystals

    Science.gov (United States)

    Lemée-Cailleau, M.-H.; McIntyre, G. J.; Wilkinson, C.

    2005-12-01

    For several decades, chemists and physicists have been fascinated by molecular compounds rich in delocalized electrons. In the solid state these compounds may offer a very rich fan of properties: optical, conduction and dielectric, magneticldots Each state is the result of a delicate balance amongst intra- and/or intermolecular interactions which can be controlled, not just by direct chemical substitution, but also by external parameters such as temperature, pressure, continuous electric or magnetic fields, or by light. The recent evolution of this field of science towards more and more sophisticated materials makes also more and more difficult their crystal growth. While neutron scattering is an extremely powerful technique to get precise structural information, it is also often disregarded in this field because usually large single crystals are required. With the recent renaissance of Laue techniques using the very intense flux provided by the reactor of the Institut Laue-Langevin (ILL), accurate structural and/or magnetic information can be now extracted routinely from molecular crystals of volume 0.1 mm3 or smaller, with easy possibilities of high pressure (up to 3 GPa) down to 0.2 K. A general survey of these new possibilities is illustrated by an example taken from the field of low-dimensional organic complexes.

  10. Evaluation of single right atrial volume and function with magnetic resonance imaging in children with hypoplastic left heart

    International Nuclear Information System (INIS)

    Vijarnsorn, Chodchanok; Myers, Kimberley; Patton, David J.; Noga, Michelle; Crawley, Cinzia; Tham, Edythe

    2016-01-01

    Standardized methods to evaluate atrial properties in single ventricles are lacking. To determine the feasibility of quantifying right atrial volumes and function in hypoplastic left heart using MRI. We studied 15 infants with hypoplastic left heart prior to Glenn surgery (mean age 4.2 months [standard deviation 0.3]) who underwent cardiac MRI with evaluation of atrial volumes and emptying fraction using monoplane two-chamber, monoplane four-chamber, and biplane methods, all of which were compared to the atrial short-axial oblique stack method. We compared atrial end-diastolic volume, end-systolic volume and emptying fraction among these methods. We analyzed reproducibility of the methods using Bland-Altman plots. Both four-chamber and biplane methods showed high correlations for atrial end-diastolic volume (r = 0.7 and r = 0.8, respectively; P < 0.01) and end-systolic volume (r = 0.8 and r = 0.9, respectively; P < 0.01) with small mean differences (-0.2 ± 2.9 standard deviation [SD] ml and -0.8 ± 1.6 ml, respectively, for atrial end-diastolic volume and -0.8 ± 1.5 ml and -0.9 ± 0.9 ml, respectively, for atrial end-systolic volume). The short-axial oblique method was the most reproducible, followed by the four-chamber method. MRI assessment of atrial volume and function is feasible in hypoplastic left heart and might provide further insight into single-ventricle mechanics. (orig.)

  11. Evaluation of single right atrial volume and function with magnetic resonance imaging in children with hypoplastic left heart

    Energy Technology Data Exchange (ETDEWEB)

    Vijarnsorn, Chodchanok [University of Alberta, Faculty of Medicine and Dentistry, Stollery Children' s Hospital, Edmonton, AB (Canada); Mahidol University, Siriraj Hospital, Bangkok (Thailand); Myers, Kimberley; Patton, David J. [Alberta Children' s Hospital, Section of Pediatric Cardiology, Department of Pediatrics, Department of Pediatrics, Calgary, AB (Canada); Noga, Michelle; Crawley, Cinzia; Tham, Edythe [University of Alberta, Faculty of Medicine and Dentistry, Stollery Children' s Hospital, Edmonton, AB (Canada)

    2016-06-15

    Standardized methods to evaluate atrial properties in single ventricles are lacking. To determine the feasibility of quantifying right atrial volumes and function in hypoplastic left heart using MRI. We studied 15 infants with hypoplastic left heart prior to Glenn surgery (mean age 4.2 months [standard deviation 0.3]) who underwent cardiac MRI with evaluation of atrial volumes and emptying fraction using monoplane two-chamber, monoplane four-chamber, and biplane methods, all of which were compared to the atrial short-axial oblique stack method. We compared atrial end-diastolic volume, end-systolic volume and emptying fraction among these methods. We analyzed reproducibility of the methods using Bland-Altman plots. Both four-chamber and biplane methods showed high correlations for atrial end-diastolic volume (r = 0.7 and r = 0.8, respectively; P < 0.01) and end-systolic volume (r = 0.8 and r = 0.9, respectively; P < 0.01) with small mean differences (-0.2 ± 2.9 standard deviation [SD] ml and -0.8 ± 1.6 ml, respectively, for atrial end-diastolic volume and -0.8 ± 1.5 ml and -0.9 ± 0.9 ml, respectively, for atrial end-systolic volume). The short-axial oblique method was the most reproducible, followed by the four-chamber method. MRI assessment of atrial volume and function is feasible in hypoplastic left heart and might provide further insight into single-ventricle mechanics. (orig.)

  12. Insights into Free Volume Variations across Ion-Exchange Membranes upon Mixed Solvents Uptake by Small and Ultrasmall Angle Neutron Scattering.

    Science.gov (United States)

    Allioux, Francois-Marie; Garvey, Christopher J; Rehm, Christine; Tardy, Blaise L; Dagastine, Raymond Riley; Hodgson, Peter D; Kong, Lingxue; Dumée, Ludovic Francis

    2017-03-15

    Ion-exchange membranes are composite separation materials increasingly used in a variety of electro-membranes and electrochemical processes. Although promising for solvent reclamation, to date, their main applications are limited to aqueous environments due to physicochemical and microstructural changes of the materials upon exposure to nonaqueous and mixed solvents solutions, affecting long-term stability and separation performance. In the present work, the structural changes of commercial and novel hybrid ion-exchange membranes in mixed methanol/water and ethanol/water solutions are assessed for the first time using ultra- and small-angle neutron scattering techniques. The interface between the ion-exchange functional layer and the mechanical support of the membranes is evaluated in the ultralow-q region, while a broad solvent-dependent peak at the mid-q region was correlated to the microstructural properties which are related to the free volume across the ion-exchange domains and to the materials electrical and nanoscale mechanical properties. The results of this study may offer new opportunities toward the development of an efficient separation process using ion-exchange membranes for the purification of fermentation broths toward biofuel generation.

  13. Transforming single domain magnetic CoFe2O4 nanoparticles from hydrophobic to hydrophilic by novel mechanochemical ligand exchange

    International Nuclear Information System (INIS)

    Munjal, Sandeep; Khare, Neeraj

    2017-01-01

    Single-phase uniform-sized (~9 nm) cobalt ferrite (CFO) nanoparticles have been synthesized by hydrothermal synthesis using oleic acid as a surfactant. The as-synthesized oleic acid-coated CFO (OA-CFO) nanoparticles were well dispersible in nonpolar solvents but not dispersible in water. The OA-CFO nanoparticles have been successfully transformed to highly water-dispersible citric acid-coated CFO (CA-CFO) nanoparticles using a novel single-step ligand exchange process by mechanochemical milling, in which small chain citric acid molecules replace the original large chain oleic acid molecules available on CFO nanoparticles. The OA-CFO nanoparticle’s hexane solution and CA-CFO nanoparticle’s water solution remain stable even after 6 months and show no agglomeration and their dispersion stability was confirmed by zeta-potential measurements. The contact angle measurement shows that OA-CFO nanoparticles are hydrophobic whereas CA-CFO nanoparticles are superhydrophilic in nature. The potentiality of as-synthesized OA-CFO and mechanochemically transformed CA-CFO nanoparticles for the demulsification of highly stabilized water-in-oil and oil-in-water emulsions has been demonstrated.

  14. Imaging in Vivo Extracellular pH with a Single Paramagnetic Chemical Exchange Saturation Transfer Magnetic Resonance Imaging Contrast Agent

    Directory of Open Access Journals (Sweden)

    Guanshu Liu

    2012-01-01

    Full Text Available The measurement of extracellular pH (pHe has potential utility for cancer diagnoses and for assessing the therapeutic effects of pH-dependent therapies. A single magnetic resonance imaging (MRI contrast agent that is detected through paramagnetic chemical exchange saturation transfer (PARACEST was designed to measure tumor pHe throughout the range of physiologic pH and with magnetic resonance saturation powers that are not harmful to a mouse model of cancer. The chemical characterization and modeling of the contrast agent Yb3+-1,4,7,10-tetraazacyclododecane-1,4,7-triacetic acid, 10-o-aminoanilide (Yb-DO3A-oAA suggested that the aryl amine of the agent forms an intramolecular hydrogen bond with a proximal carboxylate ligand, which was essential for generating a practical chemical exchange saturation transfer (CEST effect from an amine. A ratio of CEST effects from the aryl amine and amide was linearly correlated with pH throughout the physiologic pH range. The pH calibration was used to produce a parametric pH map of a subcutaneous flank tumor on a mouse model of MCF-7 mammary carcinoma. Although refinements in the in vivo CEST MRI methodology may improve the accuracy of pHe measurements, this study demonstrated that the PARACEST contrast agent can be used to generate parametric pH maps of in vivo tumors with saturation power levels that are not harmful to a mouse model of cancer.

  15. Challenges to Participation in the Sharing Economy: The Case of Local Online Peer-to-Peer Exchange in a Single Parents’ Network

    Directory of Open Access Journals (Sweden)

    Airi Lampinen

    2015-05-01

    Full Text Available This paper depicts an initiative to deploy an online peer-to-peer exchange system for a community network of single parents – a group of people in need of goods, services, and social support in their local neighborhoods. We apply participant observation and semi-structured interviews to uncover key issues that can hinder the emergence of sharing practices in local community networks of this type. Our study illustrates how pressures related to single parenthood can impede opportunities to engage in peer-to-peer exchange, even when community members view the social and material benefits of participation as desirable and necessary. This complicates the prevalent narrative that local peer-to-peer exchange systems are an accessible and convenient alternative to traditional markets. Moreover, we discuss our collaboration with the community as well as the developers of the sharing platform, highlighting the challenges of user-centered design in the sharing economy.

  16. Plasma exchange combined with azathioprine in multiple sclerosis using serial gadolinium-enhanced MRI to monitor disease activity: a randomized single-masked cross-over pilot study

    DEFF Research Database (Denmark)

    Sørensen, P.S.; Wanscher, B; Szpirt, W

    1996-01-01

    We enrolled 11 patients with secondary progressive MS in a randomized single-masked cross-over study of plasma exchange (PE) in combination with azathioprine 2 mg/kg. PE was performed once a week for 4 weeks and thereafter every second week for 20 weeks (14 treatments). Eight patients completed...

  17. Effects of a Single Bout of Resistance Exercise in Different Volumes on Endothelium Adaptations in Healthy Animals

    Directory of Open Access Journals (Sweden)

    Marcelo Mendonça Mota

    Full Text Available Abstract Background: Resistance exercise (RE has been recommended for patients with cardiovascular diseases. Recently, a few studies have demonstrated that the intensity of a single bout of RE has an effect on endothelial adaptations to exercise. However, there is no data about the effects of different volumes of RE on endothelium function. Objective: The aim of the study was to evaluate the effects of different volumes of RE in a single bout on endothelium-dependent vasodilatation and nitric oxide (NO synthesis in the mesenteric artery of healthy animals. Methods: Male Wistar rats were divided into three groups: Control (Ct; low-volume RE (LV, 5 sets x 10 repetitions and high-volume RE (HV, 15 sets x 10 repetitions. The established intensity was 70% of the maximal repetition test. After the exercise protocol, rings of mesenteric artery were used for assessment of vascular reactivity, and other mesenteric arteries were prepared for detection of measure NO production by DAF-FM fluorescence. Insulin responsiveness on NO synthesis was evaluated by stimulating the vascular rings with insulin (10 nM. Results: The maximal relaxation response to insulin increased in the HV group only as compared with the Ct group. Moreover, the inhibition of nitric oxide synthesis (L-NAME completely abolished the insulin-induced vasorelaxation in exercised rats. NO production showed a volume-dependent increase in the endothelial and smooth muscle layer. In endothelial layer, only Ct and LV groups showed a significant increase in NO synthesis when compared to their respective group under basal condition. On the other hand, in smooth muscle layer, NO fluorescence increased in all groups when compared to their respective group under basal condition. Conclusions: Our results suggest that a single bout of RE promotes vascular endothelium changes in a volume-dependent manner. The 15 sets x 10 repetitions exercise plan induced the greatest levels of NO synthesis.

  18. Highly Stereoselective Heterogeneous Diene Polymerization by Co-MFU-4l: A Single-Site Catalyst Prepared by Cation Exchange.

    Science.gov (United States)

    Dubey, Romain J-C; Comito, Robert J; Wu, Zhenwei; Zhang, Guanghui; Rieth, Adam J; Hendon, Christopher H; Miller, Jeffrey T; Dincă, Mircea

    2017-09-13

    Molecular catalysts offer tremendous advantages for stereoselective polymerization because their activity and selectivity can be optimized and understood mechanistically using the familiar tools of organometallic chemistry. Yet, this exquisite control over selectivity comes at an operational price that is generally not justifiable for the large-scale manufacture of polyfolefins. In this report, we identify Co-MFU-4l, prepared by cation exchange in a metal-organic framework, as a solid catalyst for the polymerization of 1,3-butadiene with high stereoselectivity (>99% 1,4-cis). To our knowledge, this is the highest stereoselectivity achieved with a heterogeneous catalyst for this transformation. The polymer's low polydispersity (PDI ≈ 2) and the catalyst's ready recovery and low leaching indicate that our material is a structurally resilient single-site heterogeneous catalyst. Further characterization of Co-MFU-4l by X-ray absorption spectroscopy provided evidence for discrete, tris-pyrazolylborate-like coordination of Co(II). With this information, we identify a soluble cobalt complex that mimics the structure and reactivity of Co-MFU-4l, thus providing a well-defined platform for studying the catalytic mechanism in the solution phase. This work underscores the capacity for small molecule-like tunability and mechanistic tractability available to transition metal catalysis in metal-organic frameworks.

  19. Stepwise injection potentiometric determination of caffeine in saliva using single-drop microextraction combined with solvent exchange.

    Science.gov (United States)

    Timofeeva, I; Medinskaia, K; Nikolaeva, L; Kirsanov, D; Bulatov, A

    2016-04-01

    A flow potentiometric method for determination of caffeine in saliva is suggested. This task is important for non-invasive assessment of drug metabolizing system activity in hepatocytes. In the current study, stepwise injection analysis (SWIA) was successfully combined with single-drop liquid microextraction (SDLME) and solvent exchange procedure. The method is based on the caffeine SDLME with subsequent solvent evaporation and dissolution of analyte in sulfuric acid followed by potentiometric detection using poly(vinyl chloride) membrane electrode containing potassium tetrakis[3,5-bis(trifluoromethyl)phenyl]borate as electroactive component. SDLME was employed for elimination of interfering matrix effects of saliva and caffeine metabolites such as theophylline, theobromine and paraxanthine. A linear range of 10(-5)-10(-2)M was established for caffeine with detection limit at 6 × 10(-6)M. The sample throughput was 6 samples h(-1). The proposed method was successfully applied to the determination of caffeine in saliva and the analytical results agreed well with the results obtained with reference HPLC method. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. An experimental study on single phase convection heat transfer and pressure drop in two brazed plate heat exchangers with different chevron shapes and hydraulic diameters

    International Nuclear Information System (INIS)

    Kim, Man Bae; Park, Chang Yong

    2017-01-01

    An experimental study on heat transfer and pressure drop characteristics was performed at single phase flow in two Brazed plate heat exchangers (BPHEs) with different geometries. The corrugation density of one of the BPHE (Type II) was two times as high as that of the other BPHE (Type I). The hydraulic diameter of the type II BPHE was 2.13 mm, which was 38 % smaller than that of the type I BPHE. Also, the cross section shape of the flow channels for the type II BPHE was different from that for conventional BPHEs due to the unusual corrugation patterns and brazing points. The experimental conditions for temperatures were varied from 4.6 °C to 49.1 °C, and for mass flow rates were changed from 0.07 kg/s to 1.24 kg/s. The measured results showed that pressure drop in the type II BPHE was about 110 % higher than that in the type I BPHE. Nu of the type II was higher than that of the type I BPHE and the enhancement became larger with the increase of Re at the ranges above 800. New correlations for fF and Nu were proposed by this study and their prediction accuracy could be improved by considering the surface enlargement factor in the correlations. The performance evaluation of the two BPHEs was performed by (j/f F 1 /3 ) which represented the ratio of heat transfer and pressure drop performance. Also, a new parameter, the capacity compactness of PHE, was proposed and it presented the PHE capacity per unit volume and unit log mean temperature difference. The comparison showed that the two BPHEs had similar values of the (j/f F 1 /3 ), whereas they had significantly different values of the capacity compactness. The capacity compactness of the type II BPHE was 1.5 times higher than that for the type I BPHE.

  1. Fault-Tolerant Heat Exchanger

    Science.gov (United States)

    Izenson, Michael G.; Crowley, Christopher J.

    2005-01-01

    A compact, lightweight heat exchanger has been designed to be fault-tolerant in the sense that a single-point leak would not cause mixing of heat-transfer fluids. This particular heat exchanger is intended to be part of the temperature-regulation system for habitable modules of the International Space Station and to function with water and ammonia as the heat-transfer fluids. The basic fault-tolerant design is adaptable to other heat-transfer fluids and heat exchangers for applications in which mixing of heat-transfer fluids would pose toxic, explosive, or other hazards: Examples could include fuel/air heat exchangers for thermal management on aircraft, process heat exchangers in the cryogenic industry, and heat exchangers used in chemical processing. The reason this heat exchanger can tolerate a single-point leak is that the heat-transfer fluids are everywhere separated by a vented volume and at least two seals. The combination of fault tolerance, compactness, and light weight is implemented in a unique heat-exchanger core configuration: Each fluid passage is entirely surrounded by a vented region bridged by solid structures through which heat is conducted between the fluids. Precise, proprietary fabrication techniques make it possible to manufacture the vented regions and heat-conducting structures with very small dimensions to obtain a very large coefficient of heat transfer between the two fluids. A large heat-transfer coefficient favors compact design by making it possible to use a relatively small core for a given heat-transfer rate. Calculations and experiments have shown that in most respects, the fault-tolerant heat exchanger can be expected to equal or exceed the performance of the non-fault-tolerant heat exchanger that it is intended to supplant (see table). The only significant disadvantages are a slight weight penalty and a small decrease in the mass-specific heat transfer.

  2. Effects of Exchanging Battery on the Electric Vehicle’s Electricity Consumption in a Single-Lane Traffic System

    Directory of Open Access Journals (Sweden)

    Shi-Chun Yang

    2014-01-01

    Full Text Available We propose a car-following model to explore the influences of exchanging battery on each vehicle’s electricity consumption under three traffic situations from the numerical perspective. The numerical results show that exchanging battery will destroy the stability of traffic flow, but the effects are related to each vehicle’s initial headway, the time that each electric vehicle exchanges the battery, the proportion of the electric vehicles that should exchange the battery, the number of charging stations, and the distance between two adjacent charging stations.

  3. High Power Compact Single-Frequency Volume Bragg Er-Doped Fiber Laser, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposal is based on successful results of Phase I project where it was shown that the use of volume Bragg gratings in PTR glass as selectors of transverse and...

  4. Conformation transitions of a single polyelectrolyte chain in a poor solvent: a replica-exchange lattice Monte-Carlo study.

    Science.gov (United States)

    Wang, Lang; Wang, Zheng; Jiang, Run; Yin, Yuhua; Li, Baohui

    2017-03-15

    The thermodynamic behaviors of a strongly charged polyelectrolyte chain in a poor solvent are studied using replica-exchange Monte-Carlo simulations on a lattice model, focusing on the effects of finite chain length and the solvent quality on the chain conformation and conformation transitions. The neutralizing counterions and solvent molecules are considered explicitly. The thermodynamic quantities that vary continuously with temperature over a wide range are computed using the multiple histogram reweighting method. Our results suggest that the strength of the short-range hydrophobic interaction, the chain length, and the temperature of the system, characterized by ε, N, and T, respectively, are important parameters that control the conformations of a charged chain. When ε is moderate, the competition between the electrostatic energy and the short-range hydrophobic interaction leads to rich conformations and conformation transitions for a longer chain with a fixed length. Our results have unambiguously demonstrated the stability of the n-pearl-necklace structures, where n has a maximum value and decreases with decreasing temperature. The maximum n value increases with increasing chain length. Our results have also demonstrated the first-order nature of the conformation transitions between the m-pearl and the (m-1)-pearl necklaces. With the increase of ε, the transition temperature increases and the first-order feature becomes more pronounced. It is deduced that at the thermodynamic limit of infinitely long chain length, the conformational transitions between the m-pearl and the (m-1)-pearl necklaces may remain first order when ε > 0 and m = 2 or 3. Pearl-necklace conformations cannot be observed when either ε is too large or N is too small. To observe a pearl-necklace conformation, the T value needs to be carefully chosen for simulations performed at only a single temperature.

  5. Fine structure of excitons and electron-hole exchange energy in polymorphic CsPbBr3 single nanocrystals.

    Science.gov (United States)

    Ramade, Julien; Andriambariarijaona, Léon Marcel; Steinmetz, Violette; Goubet, Nicolas; Legrand, Laurent; Barisien, Thierry; Bernardot, Frédérick; Testelin, Christophe; Lhuillier, Emmanuel; Bramati, Alberto; Chamarro, Maria

    2018-04-05

    All inorganic CsPbX3 (X = Cl, Br, I) nanocrystals (NCs) belong to the novel class of confined metal-halide perovskites which are currently arousing enthusiasm and stimulating huge activity across several fields of optoelectronics due to outstanding properties. A deep knowledge of the band-edge excitonic properties of these materials is thus crucial to further optimize their performances. Here, high-resolution photoluminescence (PL) spectroscopy of single bromide-based NCs reveals the exciton fine structure in the form of sharp peaks that are linearly polarized and grouped in doublets or triplets, which directly mirror the adopted crystalline structure, tetragonal (D4h symmetry) or orthorhombic (D2h symmetry). Intelligible equations are found that show how the fundamental parameters (spin-orbit coupling, ΔSO, crystal field term, T, and electron-hole exchange energy, J) rule the energy spacings in doublets and triplets. From experimental data, fine estimations of each parameter are obtained. The analysis of the absorption spectra of an ensemble of NCs with a "quasi-bulk" behavior leads to ΔSO = 1.20 ± 0.06 eV and T = -0.34 ± 0.05 eV in CsPbBr3. The study of individual luminescence responses of NCs having sizes comparable to the exciton Bohr diameter, 7 nm, allows us to estimate the value of J to be around ≈3 meV in both tetragonal and orthorhombic phases. This value is already enhanced by confinement.

  6. Measurement and Calculation of Absolute Single- and Multiple-Charge-Exchange Cross Sections for Feq+ Ions Impacting CO and CO2

    Energy Technology Data Exchange (ETDEWEB)

    Simcic, J. [Jet Propulsion Laboratory/Caltech; Schultz, David Robert [ORNL; Mawhorter, R. J. [Pomona College; Cadez, I. [Jozef Stefan Institute, Slovenia; Greenwood, J. B. [Queen' s University, Belfast; Chutjian, A. [Jet Propulsion Laboratory/Caltech; Lisse, Carey M. [Johns Hopkins University; Smith, S. J. [Indiana Wesleyan University, Marion

    2010-01-01

    Absolute cross sections are reported for single, double, and triple charge exchange of Feq+ (q=5- 13) ions with CO and CO2. The highly-charged Fe ions are generated in an electron cyclotron resonance ion source. Absolute data are derived from knowledge of the target gas pressure, target path length, and incident and charge-exchanged ion currents. Experimental results are compared with new calculations of these cross sections in the n-electron classical trajectory Monte-Carlo approximation, in which the ensuing radiative and non-radiative cascades are approximated with scaled hydrogenic transition probabilities and scaled Auger rates. The present data are needed in astrophysical applications of solar- and stellar-wind charge-exchange with comets, planetary atmospheres, and circumstellar clouds.

  7. Self-Similar Nanocavity Design with Ultrasmall Mode Volume for Single-Photon Nonlinearities

    DEFF Research Database (Denmark)

    Choi, Hyeongrak; Heuck, Mikkel; Englund, Dirk R.

    2017-01-01

    illustrate the design concept with a silicon-air one-dimensional photon crystal cavity that reaches an ultrasmall mode volume of V-eff similar to 7.01 x 10(-5)lambda(3) at lambda similar to 1550 nm. We show that the extreme light concentration in our design can enable ultrastrong Kerr nonlinearities, even...

  8. Reliability of estimating the room volume from a single room impulse response

    NARCIS (Netherlands)

    Kuster, M.

    2008-01-01

    The methods investigated for the room volume estimation are based on geometrical acoustics, eigenmode, and diffuse field models and no data other than the room impulse response are available. The measurements include several receiver positions in a total of 12 rooms of vastly different sizes and

  9. Plasma exchange combined with azathioprine in multiple sclerosis using serial gadolinium-enhanced MRI to monitor disease activity: a randomized single-masked cross-over pilot study

    DEFF Research Database (Denmark)

    Sørensen, P.S.; Wanscher, B; Szpirt, W

    1996-01-01

    We enrolled 11 patients with secondary progressive MS in a randomized single-masked cross-over study of plasma exchange (PE) in combination with azathioprine 2 mg/kg. PE was performed once a week for 4 weeks and thereafter every second week for 20 weeks (14 treatments). Eight patients completed...... in the two periods. Although the total MS lesion load on MRI was significantly lower (p effect of PE or encourage a subsequent large...

  10. Estimation of bias with the single-zone assumption in measurement of residential air exchange using the perfluorocarbon tracer gas method.

    Science.gov (United States)

    Van Ryswyk, K; Wallace, L; Fugler, D; MacNeill, M; Héroux, M È; Gibson, M D; Guernsey, J R; Kindzierski, W; Wheeler, A J

    2015-12-01

    Residential air exchange rates (AERs) are vital in understanding the temporal and spatial drivers of indoor air quality (IAQ). Several methods to quantify AERs have been used in IAQ research, often with the assumption that the home is a single, well-mixed air zone. Since 2005, Health Canada has conducted IAQ studies across Canada in which AERs were measured using the perfluorocarbon tracer (PFT) gas method. Emitters and detectors of a single PFT gas were placed on the main floor to estimate a single-zone AER (AER(1z)). In three of these studies, a second set of emitters and detectors were deployed in the basement or second floor in approximately 10% of homes for a two-zone AER estimate (AER(2z)). In total, 287 daily pairs of AER(2z) and AER(1z) estimates were made from 35 homes across three cities. In 87% of the cases, AER(2z) was higher than AER(1z). Overall, the AER(1z) estimates underestimated AER(2z) by approximately 16% (IQR: 5-32%). This underestimate occurred in all cities and seasons and varied in magnitude seasonally, between homes, and daily, indicating that when measuring residential air exchange using a single PFT gas, the assumption of a single well-mixed air zone very likely results in an under prediction of the AER. The results of this study suggest that the long-standing assumption that a home represents a single well-mixed air zone may result in a substantial negative bias in air exchange estimates. Indoor air quality professionals should take this finding into consideration when developing study designs or making decisions related to the recommendation and installation of residential ventilation systems. © 2014 Her Majesty the Queen in Right of Canada. Indoor Air published by John Wiley & Sons Ltd Reproduced with the permission of the Minister of Health Canada.

  11. In a Canine Pneumonia Model of Exchange-Transfusion, Altering the Age but Not the Volume of Older Red Blood Cells Markedly Alters Outcome

    Science.gov (United States)

    Cortés-Puch, Irene; Remy, Kenneth E.; Solomon, Steven B.; Sun, Junfeng; Wang, Dong; Al-Hamad, Mariam; Kelly, Seth M.; Sinchar, Derek; Bellavia, Landon; Kanias, Tamir; Popovsky, Mark A.; Kim-Shapiro, Daniel B.; Klein, Harvey G.; Natanson, Charles

    2015-01-01

    Background Massive exchange-transfusion of 42-day-old red blood cells (RBCs) in a canine model of S. aureus pneumonia resulted in in vivo hemolysis with increases in cell-free hemoglobin (CFH), transferrin bound iron (TBI), non-transferrin bound iron (NTBI), and mortality. We have previously shown that washing 42-day-old RBCs before transfusion significantly decreased NTBI levels and mortality, but washing 7-day-old RBCs increased mortality and CFH levels. We now report the results of altering volume, washing, and age of RBCs. Study Design and Methods Two-year-old purpose-bred infected beagles were transfused with increasing volumes (5-10, 20-40, or 60-80 mL/kg) of either 42- or 7-day-old RBCs (n=36) or 80 mL/kg of either unwashed or washed RBCs with increasing storage age (14, 21, 28, or 35 days) (n=40). Results All volumes transfused (5-80 mL/kg) of 42-day-old RBCs, resulted in alike (i.e., not significantly different) increases in TBI during transfusion as well as in CFH, lung injury, and mortality rates after transfusion. Transfusion of 80 mL/kg of RBCs stored for 14, 21, 28 and 35 days resulted in increased CFH and NTBI in between levels found at 7 and 42 days of storage. However, washing RBCs of intermediate ages (14-35 days) does not alter NTBI and CFH levels or mortality rates. Conclusions Preclinical data suggest that any volume of 42-day-old blood potentially increases risks during established infection. In contrast, even massive volumes of 7-day-old blood result in minimal CFH and NTBI levels and risks. In contrast to the extremes of storage, washing blood stored for intermediate ages does not alter risks of transfusion or NTBI and CFH clearance. PMID:26469998

  12. High Power Compact Single-Frequency Volume Bragg Er-Doped Fiber Laser, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The purpose of this NASA SBIR Phase I proposal is to develop the prototype of a compact single-frequency mode one longitudinal and one transverse mode laser...

  13. Identification and weighting factors influencing the establishment of a single minute exchange of dies in plastic injection industry using VIKOR and Shannon Entropy

    Directory of Open Access Journals (Sweden)

    Gholam Reza Hashemzadeh

    2014-05-01

    Full Text Available Single minute exchange of dies (SMED is one of the most important tools to achieve lean production system. The main idea of this system is to provide methods and to use creative and innovative solutions for continuous improvement. Due to the importance of this issue and its effect on reducing waste during the production process, this study presents a method to identify and to weight factors in the establishment of a single minute exchange of dies in 14 plastic injection factories. In this study, fourteen factories in injection industry were chosen and the factors influencing the implementation of single minute exchange of dies were identified. Following data collection, decision matrix was formed and the weight of each factor was determined by using Shannon Entropy. Then, in order to determine the readiness of factories, VIKOR method was used to rank companies. The results indicate priorities of the following factors in establishing SMED that include: Senior management support, technical capabilities, technical knowledge of staff and consultants, knowledge of mold design, manufacturing infrastructure, team work, combination of the project team work, benchmarking, training, clear understanding of project objectives, rewards and motivation, proper management expectation, project management, teamwork and organizational culture. Practical implications: Due to the factors, Top manager can make the best decision for implementing of SMED technique. This study develops factors influencing on SMED implementation based on Shannon and VIKOR methods for ranking parameters and plants.

  14. Escherichia coli Single-Stranded DNA-Binding Protein: NanoESI-MS Studies of Salt-Modulated Subunit Exchange and DNA Binding Transactions

    Science.gov (United States)

    Mason, Claire E.; Jergic, Slobodan; Lo, Allen T. Y.; Wang, Yao; Dixon, Nicholas E.; Beck, Jennifer L.

    2013-02-01

    Single-stranded DNA-binding proteins (SSBs) are ubiquitous oligomeric proteins that bind with very high affinity to single-stranded DNA and have a variety of essential roles in DNA metabolism. Nanoelectrospray ionization mass spectrometry (nanoESI-MS) was used to monitor subunit exchange in full-length and truncated forms of the homotetrameric SSB from Escherichia coli. Subunit exchange in the native protein was found to occur slowly over a period of hours, but was significantly more rapid in a truncated variant of SSB from which the eight C-terminal residues were deleted. This effect is proposed to result from C-terminus mediated stabilization of the SSB tetramer, in which the C-termini interact with the DNA-binding cores of adjacent subunits. NanoESI-MS was also used to examine DNA binding to the SSB tetramer. Binding of single-stranded oligonucleotides [one molecule of (dT)70, one molecule of (dT)35, or two molecules of (dT)35] was found to prevent SSB subunit exchange. Transfer of SSB tetramers between discrete oligonucleotides was also observed and is consistent with predictions from solution-phase studies, suggesting that SSB-DNA complexes can be reliably analyzed by ESI mass spectrometry.

  15. Measurement of nucleotide exchange rate constants in single rabbit soleus myofibrils during shortening and lengthening using a fluorescent ATP analog.

    Science.gov (United States)

    Shirakawa, I; Chaen, S; Bagshaw, C R; Sugi, H

    2000-02-01

    The kinetics of displacement of a fluorescent nucleotide, 2'(3')-O-[N[2-[[Cy3]amido]ethyl]carbamoyl]-adenosine 5'-triphosphate (Cy3-EDA-ATP), bound to rabbit soleus muscle myofibrils were studied using flash photolysis of caged ATP. Use of myofibrils from this slow twitch muscle allowed better resolution of the kinetics of nucleotide exchange than previous studies with psoas muscle myofibrils (, Biophys. J. 73:2033-2042). Soleus myofibrils in the presence of Cy3-EDA-nucleotides (Cy3-EDA-ATP or Cy3-EDA-ADP) showed selective fluorescence staining of the A-band. The K(m) for Cy3-EDA-ATP and the K(d) for Cy3-EDA-ADP binding to the myofibril A-band were 1.9 microM and 3.8 microM, respectively, indicating stronger binding of nucleotide to soleus cross-bridges compared to psoas cross-bridges (2.6 microM and 50 microM, respectively). After flash photolysis of caged ATP, the A-band fluorescence of the myofibril in the Cy3-EDA-ATP solution under isometric conditions decayed exponentially with a rate constant of 0.045 +/- 0.007 s(-1) (n = 32) at 10 degrees C, which was about seven times slower than that for psoas myofibrils. When a myofibril was allowed to shorten with a constant velocity, the nucleotide displacement rate constant increased from 0.066 s(-1) (isometric) to 0.14 s(-1) at 20 degrees C with increasing shortening velocity up to 0.1 myofibril length/s (V(max), the shortening velocity under no load was approximately 0. 2 myofibril lengths/s). The rate constant was not significantly affected by an isovelocity stretch of up to 0.1 myofibril lengths/s. These results suggest that the cross-bridge kinetics are not significantly affected at higher strain during lengthening but depend on the lower strain during shortening. These data also indicate that the interaction distance between a cross-bridge and the actin filament is at least 16 nm for a single cycle of the ATPase.

  16. Reliability of estimating the room volume from a single room impulse response

    OpenAIRE

    Kuster, M.

    2008-01-01

    The methods investigated for the room volume estimation are based on geometrical acoustics, eigenmode, and diffuse field models and no data other than the room impulse response are available. The measurements include several receiver positions in a total of 12 rooms of vastly different sizes and acoustic characteristics. The limitations in identifying the pivotal specular reflections of the geometrical acoustics model in measured room impulse responses are examined both theoretically and expe...

  17. High-power, single-frequency, continuous-wave optical parametric oscillator employing a variable reflectivity volume Bragg grating.

    Science.gov (United States)

    Zeil, Peter; Thilmann, Nicky; Pasiskevicius, Valdas; Laurell, Fredrik

    2014-12-01

    A continuous-wave singly-resonant optical parametric oscillator (SRO) with an optimum extraction efficiency, that can be adjusted independent of the pump power, is demonstrated. The scheme employs a variable-reflectivity volume Bragg grating (VBG) as the output coupler of a ring cavity, omitting any additional intra-cavity elements. In this configuration, we obtained a 75%-efficient SRO with a combined signal (19 W @ 1.55 µm) and idler (11 W @ 3.4 µm) output power of 30 W.

  18. The volumes and transcript counts of single cells reveal concentration homeostasis and capture biological noise.

    NARCIS (Netherlands)

    Kempe, H.; Schwabe, A.; Crémazy, F.; Verschure, P.J.; Bruggeman, F.J.

    2015-01-01

    Transcriptional stochasticity can be measured by counting the number of mRNA molecules per cell. Cell-to-cell variability is best captured in terms of concentration rather than molecule counts, because reaction rates depend on concentrations. We combined single-molecule mRNA counting with

  19. Single Cell Transfection through Precise Microinjection with Quantitatively Controlled Injection Volumes

    Science.gov (United States)

    Chow, Yu Ting; Chen, Shuxun; Wang, Ran; Liu, Chichi; Kong, Chi-Wing; Li, Ronald A.; Cheng, Shuk Han; Sun, Dong

    2016-04-01

    Cell transfection is a technique wherein foreign genetic molecules are delivered into cells. To elucidate distinct responses during cell genetic modification, methods to achieve transfection at the single-cell level are of great value. Herein, we developed an automated micropipette-based quantitative microinjection technology that can deliver precise amounts of materials into cells. The developed microinjection system achieved precise single-cell microinjection by pre-patterning cells in an array and controlling the amount of substance delivered based on injection pressure and time. The precision of the proposed injection technique was examined by comparing the fluorescence intensities of fluorescent dye droplets with a standard concentration and water droplets with a known injection amount of the dye in oil. Injection of synthetic modified mRNA (modRNA) encoding green fluorescence proteins or a cocktail of plasmids encoding green and red fluorescence proteins into human foreskin fibroblast cells demonstrated that the resulting green fluorescence intensity or green/red fluorescence intensity ratio were well correlated with the amount of genetic material injected into the cells. Single-cell transfection via the developed microinjection technique will be of particular use in cases where cell transfection is challenging and genetically modified of selected cells are desired.

  20. Effects of a Single Bout of Resistance Exercise in Different Volumes on Endothelium Adaptations in Healthy Animals.

    Science.gov (United States)

    Mota, Marcelo Mendonça; Silva, Tharciano Luiz Teixeira Braga da; Macedo, Fabricio Nunes; Mesquita, Thássio Ricardo Ribeiro; Quintans, Lucindo José; Santana-Filho, Valter Joviniano de; Lauton-Santos, Sandra; Santos, Márcio Roberto Viana

    2017-05-01

    Resistance exercise (RE) has been recommended for patients with cardiovascular diseases. Recently, a few studies have demonstrated that the intensity of a single bout of RE has an effect on endothelial adaptations to exercise. However, there is no data about the effects of different volumes of RE on endothelium function. The aim of the study was to evaluate the effects of different volumes of RE in a single bout on endothelium-dependent vasodilatation and nitric oxide (NO) synthesis in the mesenteric artery of healthy animals. Male Wistar rats were divided into three groups: Control (Ct); low-volume RE (LV, 5 sets x 10 repetitions) and high-volume RE (HV, 15 sets x 10 repetitions). The established intensity was 70% of the maximal repetition test. After the exercise protocol, rings of mesenteric artery were used for assessment of vascular reactivity, and other mesenteric arteries were prepared for detection of measure NO production by DAF-FM fluorescence. Insulin responsiveness on NO synthesis was evaluated by stimulating the vascular rings with insulin (10 nM). The maximal relaxation response to insulin increased in the HV group only as compared with the Ct group. Moreover, the inhibition of nitric oxide synthesis (L-NAME) completely abolished the insulin-induced vasorelaxation in exercised rats. NO production showed a volume-dependent increase in the endothelial and smooth muscle layer. In endothelial layer, only Ct and LV groups showed a significant increase in NO synthesis when compared to their respective group under basal condition. On the other hand, in smooth muscle layer, NO fluorescence increased in all groups when compared to their respective group under basal condition. Our results suggest that a single bout of RE promotes vascular endothelium changes in a volume-dependent manner. The 15 sets x 10 repetitions exercise plan induced the greatest levels of NO synthesis. O exercício resistido (ER) tem sido recomendado para pacientes com doen

  1. Estimate Landslide Volume with Genetic Algorithms and Image Similarity Method from Single Satellite Image

    Science.gov (United States)

    Yu, Ting-To

    2013-04-01

    It is important to acquire the volume of landslide in short period of time. For hazard mitigation and also emergency response purpose, the traditional method takes much longer time than expected. Due to the weather limit, traffic accessibility and many regulations of law, it take months to handle these process before the actual carry out of filed work. Remote sensing imagery can get the data as long as the visibility allowed, which happened only few day after the event. While traditional photometry requires a stereo pairs images to produce the post event DEM for calculating the change of volume. Usually have to wait weeks or even months for gathering such data, LiDAR or ground GPS measurement might take even longer period of time with much higher cost. In this study we use one post event satellite image and pre-event DTM to compare the similarity between these by alter the DTM with genetic algorithms. The outcome of smartest guess from GAs shall remove or add exact values of height at each location, which been converted into shadow relief viewgraph to compare with satellite image. Once the similarity threshold been make then the guessing work stop. It takes only few hours to finish the entire task, the computed accuracy is around 70% by comparing to the high resolution LiDAR survey at a landslide, southern Taiwan. With extra GCPs, the estimate accuracy can improve to 85% and also within few hours after the receiving of satellite image. Data of this demonstration case is a 5 m DTM at 2005, 2M resolution FormoSat optical image at 2009 and 5M LiDAR at 2010. The GAs and image similarity code is developed on Matlab at windows PC.

  2. On-Line Monitoring and Diagnostics of the Integrity of Nuclear Plant Steam Generators and Heat Exchangers, Volumes 1, 2

    Energy Technology Data Exchange (ETDEWEB)

    Upadhyaya, Belle R. [Univ. of Tennessee, Knoxville, TN (United States); Hines, J. Wesley [Univ. of Tennessee, Knoxville, TN (United States); Lu, Baofu [Univ. of Tennessee, Knoxville, TN (United States)

    2005-06-03

    The overall purpose of this Nuclear Engineering Education Research (NEER) project was to integrate new, innovative, and existing technologies to develop a fault diagnostics and characterization system for nuclear plant steam generators (SG) and heat exchangers (HX). Issues related to system level degradation of SG and HX tubing, including tube fouling, performance under reduced heat transfer area, and the damage caused by stress corrosion cracking, are the important factors that influence overall plant operation, maintenance, and economic viability of nuclear power systems. The research at The University of Tennessee focused on the development of techniques for monitoring process and structural integrity of steam generators and heat exchangers. The objectives of the project were accomplished by the completion of the following tasks. All the objectives were accomplished during the project period. This report summarizes the research and development activities, results, and accomplishments during June 2001 September 2004. Development and testing of a high-fidelity nodal model of a U-tube steam generator (UTSG) to simulate the effects of fouling and to generate a database representing normal and degraded process conditions. Application of the group method of data handling (GMDH) method for process variable prediction. Development of a laboratory test module to simulate particulate fouling of HX tubes and its effect on overall thermal resistance. Application of the GMDH technique to predict HX fluid temperatures, and to compare with the calculated thermal resistance.Development of a hybrid modeling technique for process diagnosis and its evaluation using laboratory heat exchanger test data. Development and testing of a sensor suite using piezo-electric devices for monitoring structural integrity of both flat plates (beams) and tubing. Experiments were performed in air, and in water with and without bubbly flow. Development of advanced signal processing methods using

  3. The role of power exchanges for the creation of a single European electricity market: market design and market regulation

    International Nuclear Information System (INIS)

    Boisseleau, F.

    2004-01-01

    The electricity sector worldwide is undergoing a fundamental transformation of its institutional structure as a consequence of the complex interactions of political, economic and technological forces. The way the industry is organized is changing from vertically integrated monopolies to unbundled structures that favor market mechanisms. This process in Europe, known as the liberalization process, has had a wide impact on the European electricity industry. The focus of this dissertation is an analysis of the role of electricity power exchanges in the recently liberalized electricity markets of Europe. In the context of creating a competitive electricity market at a European level, the key questions considered are the functioning of these power exchanges with respect to electricity characteristics, market design and regulatory framework. In Europe, very little attention has been paid to the role of these new marketplaces and to the issue of market design in general. Hence the main purpose of this work was to analyze how these marketplaces facilitate the trading of electricity and the role they can play in the construction of a pan-European competitive electricity market. An analysis of power exchange requires taking into account the 'double-duality' of such institutions. One, power exchanges are both a market and an institution. As a market they facilitate the trading of electricity and determine an equilibrium price. As an institution power exchanges have their own objectives and constraints, and play a role in the market design of the overall electricity market. Two, the relationship between electricity power exchanges and liberalization is neither linear nor one way: liberalization encourages the birth of such marketplaces yet marketplaces are more than the results of such process, they are also a driving force of the liberalization process. This thesis is divided into three parts. The current situation in Europe and different existing theoretical approaches in

  4. Magnetic properties of weakly exchange-coupled high spin Co(II) ions in pseudooctahedral coordination evaluated by single crystal X-band EPR spectroscopy and magnetic measurements.

    Science.gov (United States)

    Neuman, Nicolás I; Winkler, Elín; Peña, Octavio; Passeggi, Mario C G; Rizzi, Alberto C; Brondino, Carlos D

    2014-03-03

    We report single-crystal X-band EPR and magnetic measurements of the coordination polymer catena-(trans-(μ2-fumarato)tetraaquacobalt(II)), 1, and the Co(II)-doped Zn(II) analogue, 2, in different Zn:Co ratios. 1 presents two magnetically inequivalent high spin S = 3/2 Co(II) ions per unit cell, named A and B, in a distorted octahedral environment coordinated to four water oxygen atoms and trans coordinated to two carboxylic oxygen atoms from the fumarate anions, in which the Co(II) ions are linked by hydrogen bonds and fumarate molecules. Magnetic susceptibility and magnetization measurements of 1 indicate weak antiferromagnetic exchange interactions between the S = 3/2 spins of the Co(II) ions in the crystal lattice. Oriented single crystal EPR experiments of 1 and 2 were used to evaluate the molecular g-tensor and the different exchange coupling constants between the Co(II) ions, assuming an effective spin S′= 1/2. Unexpectedly, the eigenvectors of the molecular g-tensor were not lying along any preferential bond direction, indicating that, in high spin Co(II) ions in roughly octahedral geometry with approximately axial EPR signals, the presence of molecular pseudo axes in the metal site does not determine preferential directions for the molecular g-tensor. The EPR experiment and magnetic measurements, together with a theoretical analysis relating the coupling constants obtained from both techniques, allowed us to evaluate selectively the exchange coupling constant associated with hydrogen bonds that connect magnetically inequivalent Co(II) ions (|JAB(1/2)| = 0.055(2) cm(–1)) and the exchange coupling constant associated with a fumarate bridge connecting equivalent Co(II) ions (|JAA(1/2)| ≈ 0.25 (1) cm(–1)), in good agreement with the average J(3/2) value determined from magnetic measurements.

  5. Rapid MR imaging of the liver. Comparison of twelve techniques for single breath-hold whole volume acquisition

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Jenner, Goeran; Cooper, T.G.; Potchen, E.J.; Ishigaki, Takeo

    1994-01-01

    Twelve magnetic resonance imaging pulse sequences for single breath-hold whole volume acquisition of the liver were evaluated on volunteers. Liver and spleen contrast to noise ratio (C/N), overall image quality, and grade of artifacts were compared. The 12 sequences included T 2 -weighted fast spin echo (FSE) with or without fat suppression (FS), fast multiplanar spoiled gradient recalled imaging (FMPSPGR), fast gradient recalled imaging without preparation pulses (FGR), FGR with inversion recovery preparation pulse nulling the liver or fat (IR-FGR-L and IR-FGR-F), FGR with driven equilibrium preparation pulse (DE-FGR), single shot moderately or heavily T 2 -weighted spin echo echo planar imaging (SE-EPI-mT2 and SE-EPI-hT2), multi-shot moderately T 2 -weighted spin echo echo planar imaging (multi-shot SE-EPI-mT2), inversion recovery EPI, and gradient echo EPI. In the quantitative analysis, FSE + FS showed a significantly higher C/N ratio than the others (p<0.05). In the qualitative evaluation, DE-prepFGR, and single and multi-shot SE-EPI-mT2 had good results, as did FSE and FSE + FS. Further studies should be conducted to determine whether or not these breath-hold sequences can obviate current conventional non-breath-hold sequences. (author)

  6. The orthogonal in-situ machining of single and polycrystalline aluminum and copper, volume 1

    Science.gov (United States)

    Cohen, P. H.

    1982-05-01

    Metal cutting is a unique deformation process characterized by large strains, exceptionally high strain rates and few constraints to the deformation. These factors, along with the difficulty of directly measuring the shear angle, make chip formation difficult to model and understand. One technique for skirting the difficulty of post mortem chip measurement is to perform a cutting experiment dynamically in a scanning electron microscope. The performance of the in-situ experiment with full instrumentation allows for component force measurement, orientation measurement (on a round single crystal disk) and a timing device, all superimposed below the deformation on the TV monitor and recorded for future viewing. This allows the sher angle to be directly measured for the screen along with the other needed information.

  7. The optimal anatomic site for a single slice to estimate the total volume of visceral adipose tissue by using the quantitative computed tomography (QCT) in Chinese population.

    Science.gov (United States)

    Cheng, X; Zhang, Y; Wang, C; Deng, W; Wang, L; Duanmu, Y; Li, K; Yan, D; Xu, L; Wu, C; Shen, W; Tian, W

    2018-03-20

    To investigate the relationship between the cross-sectional visceral adipose tissue (VAT) areas at different anatomic sites and the total VAT volume in a healthy Chinese population using quantitative computed tomography (QCT), and to identify the optimal anatomic site for a single slice to estimate the total VAT volume. A total of 389 healthy Chinese subjects aged 19-63 years underwent lumbar spine QCT scans. The cross-sectional area of total adipose tissue and VAT were measured using the tissue composition module of the software (QCT Pro, Mindways) at each intervertebral disc level from T 12 /L 1 to L 5 /S 1 , as well as at the umbilical level. The total VAT volume was defined as the fat areas multiplied by the height of vertebral body for all six slices. Statistical analysis was performed to determine the correlation between single-slice VAT areas and the total VAT volume. Moreover, the optimal anatomic site for a single slice to estimate the total VAT volume was identified by multiple regression analysis. The cross-sectional area of VAT and subcutaneous adipose tissue (SAT) measured at each anatomic site was all highly correlated with the total VAT volume and the total SAT volume (r = 0.89-0.98). Additionally, the VAT area measured at the L 2 /L 3 level showed the strongest correlation with the total VAT volume (r = 0.98, P VAT volume. It is feasible to perform measurements of VAT area on a single slice at L 2 /L 3 level for estimating the total VAT volume.

  8. Mechanical properties of ANTRIX balloon film and fabrication of single cap large volume balloons

    Science.gov (United States)

    Suneel Kumar, B.; Sreenivasan, S.; Subba Rao, J. V.; Manchanda, R. K.

    2008-11-01

    The zero pressure plastic balloons used for high altitude studies are generally made from polyethylene material. Tensile properties of the thin film polymer are the key parameters for material selection due to extremely low temperature of -90 °C encountered by the balloons in the tropopause region during the ascent at equatorial latitudes. The physical and structural properties of the material determine the uniformity of the stress distribution over the entire shell. Load stresses from the suspended load propagate via load tapes heat sealed along with the gore seals as per the balloon design. A balance between this heat seal strength and the film strength is a desirable property of the basic resin in terms of the bubble strength, gauge uniformity, and long-term storage properties. In addition, the design of the top shell of the balloon and its stress distribution play an important role since only a fraction of the balloon is deployed during the filling operation and the ascent. In this paper we describe the mechanical properties of the 'ANTRIX' film developed by us and the optimized design of single cap balloons, which have been successfully used in our experiments over the past 5 years.

  9. Columbia University flow instability experimental program: Volume 6. Single annulus tests, transient test program

    Energy Technology Data Exchange (ETDEWEB)

    Dougherty, T.; Maciuca, C.; McAssey, E.V. Jr.; Reddy, D.G.; Yang, B.W.

    1992-09-01

    The coolant in the Savannah River Site (SRS) production nuclear reactor assemblies is circulated as a subcooled liquid under normal operating conditions. This coolant is evenly distributed throughout multiple annular flow channels with a uniform pressure profile across each coolant flow channel. During the postulated Loss of Coolant Accident (LOCA), which is initiated by a hypothetical guillotine pipe break, the coolant flow through the reactor assemblies is significantly reduced. The flow reduction and accompanying power reduction (after shutdown is initiated) occur in the first 1 to 2 seconds of the LOCA. This portion of the LOCA is referred to as the Flow Instability phase. This report presents the experimental results for the transient portion of the single annulus test program. The test program was designed to investigate the onset of flow instability in an annular geometry similar to the MARK 22 reactor. The test program involved testing of both a ribless heater and a ribbed heater under steady state as well as transient conditions. The ribbed heater testing is currently underway and will be reported separately. The steady state portion of this test program with ribless heater was completed and reported in report No. CU-HTRF-T3A. The present report presents transient test results obtained from a ribless, uniform annulus test section. A total of thirty five transients were conducted with six cases in which flow excursion occurred. No unstable conditions resulted for tests in which the steady state Q{sub ratio} OFI limit was not exceeded.

  10. V-cut twisted tape insert effect on heat transfer enhancement of single phase turbulent flow heat exchanger

    Science.gov (United States)

    Yaningsih, Indri; Wijayanta, Agung Tri; Miyazaki, Takahiko; Koyama, Shigeru

    2018-02-01

    Turbulator is recognized as a method to increase the performance of the heat exchanger. Turbulator in the form of V-cut twisted tape insert could help to increase the performance by enhancing the coefficient of the heat transfer. This paper proposes a new design of V-cut twisted tape insert (VTT) with different width ratio (w/W), which investigated on the heat transfer enhancement, in the form of Nusselt number (Nu) and friction factor (f) characteristics. Three different width ratios (w/W) 0.32; 0.38 and 0.48 are introduced in this experiment. The working fluid is the hot water in the inner tube and cold water in the annulus, the flow direction is counter-flow. The temperature inlet of hot water is kept constant at 60°C while the flow rate is in the range of Reynolds number 5400 - 17,350. The heat exchanger without insertion (plain tube) and typical twisted tape insert (TT) are examined for comparison. Results indicate that the proposed VTT increases the heat transfer, friction factor, and thermal performance of the heat exchanger. Under the similar condition, VTT provides the best performance in comparison with TT and plain tube. Decreasing width ratio (w/W) increases the heat transfer and thermal performance. However, when the heat transfer is increased, the friction factor is also increasing. The results also revealed that the use of the VTT and TT, the increase in the heat transfer and friction factor up to 97% and 3.48 times of the plain tube. The highest thermal performance is 1.4.

  11. Fibrous polymer grafted magnetic chitosan beads with strong poly(cation-exchange) groups for single step purification of lysozyme.

    Science.gov (United States)

    Bayramoglu, Gulay; Tekinay, Turgay; Ozalp, V Cengiz; Arica, M Yakup

    2015-05-15

    Lysozyme is an important polypetide used in medical and food applications. We report a novel magnetic strong cation exchange beads for efficient purification of lysozyme from chicken egg white. Magnetic chitosan (MCHT) beads were synthesized via phase inversion method, and then grafted with poly(glycidyl methacrylate) (p(GMA)) via the surface-initiated atom transfer radical polymerization (SI-ATRP). Epoxy groups of the grafted polymer, were modified into strong cation-exchange groups (i.e., sulfonate groups) in the presence of sodium sulfite. The MCTH and MCTH-g-p(GMA)-SO3H beads were characterized by ATR-FTIR, SEM, and VSM. The sulphonate groups content of the modified MCTH-g-p(GMA)-4 beads was found to be 0.53mmolg(-1) of beads by the potentiometric titration method. The MCTH-g-p(GMA)-SO3H beads were first used as an ion-exchange support for adsorption of lysozyme from aqueous solution. The influence of different experimental parameters such as pH, contact time, and temperature on the adsorption process was evaluated. The maximum adsorption capacity was found to be 208.7mgg(-1) beads. Adsorption of lysozyme on the MCTH-g-p(GMA)-SO3H beads fitted to Langmuir isotherm model and followed the pseudo second-order kinetic. More than 93% of the adsorbed lysozyme was desorbed using Na2CO3 solution (pH 11.0). The purity of the lysozyme was checked by HPLC and SDS gel electrophoresis. In addition, the MCTH-g-p(GMA)-SO3H beads prepared in this work showed promising potential for separation of various anionic molecules. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Methods for preparing polymer-decorated single exchange-biased magnetic nanoparticles for application in flexible polymer-based films

    Directory of Open Access Journals (Sweden)

    Laurence Ourry

    2017-02-01

    Full Text Available Background: Magnetic nanoparticles (NPs must not only be well-defined in composition, shape and size to exhibit the desired properties (e.g., exchange-bias for thermal stability of the magnetization but also judiciously functionalized to ensure their stability in air and their compatibility with a polymer matrix, in order to avoid aggregation which may seriously affect their physical properties. Dipolar interactions between NPs too close to each other favour a collective magnetic glass state with lower magnetization and coercivity because of inhomogeneous and frustrated macrospin cluster freezing. Consequently, tailoring chemically (through surface functionalization and magnetically stable NPs for technological applications is of primary importance.Results: In this work, well-characterized exchange-biased perfectly epitaxial CoxFe3−xO4@CoO core@shell NPs, which were isotropic in shape and of about 10 nm in diameter, were decorated by two different polymers, poly(methyl methacrylate (PMMA or polystyrene (PS, using radical-controlled polymerization under various processing conditions. We compared the influence of the synthesis parameters on the structural and microstructural properties of the resulting hybrid systems, with special emphasis on significantly reducing their mutual magnetic attraction. For this, we followed two routes: the first one consists of the direct grafting of bromopropionyl ester groups at the surface of the NPs, which were previously recovered and redispersed in a suitable solvent. The second route deals with an “all in solution” process, based on the decoration of NPs by oleic acid followed by ligand exchange with the desired bromopropionyl ester groups. We then built various assemblies of NPs directly on a substrate or suspended in PMMA.Conclusion: The alternative two-step strategy leads to better dispersed polymer-decorated magnetic particles, and the resulting nanohybrids can be considered as valuable building

  13. Simultaneous single-molecule measurements of phage T7 replisome composition and function reveal the mechanism of polymerase exchange

    NARCIS (Netherlands)

    Loparo, Joseph J.; Kulczyk, Arkadiusz W.; Richardson, Charles C.; Oijen, Antoine M. van

    2011-01-01

    A complete understanding of the molecular mechanisms underlying the functioning of large, multiprotein complexes requires experimental tools capable of simultaneously visualizing molecular architecture and enzymatic activity in real time. We developed a novel single-molecule assay that combines the

  14. Exploring sub-daily to seasonal variations in methane exchange in a single-crop rice paddy in central Japan

    Science.gov (United States)

    Iwata, Hiroki; Mano, Masayoshi; Ono, Keisuke; Tokida, Takeshi; Kawazoe, Takahiro; Kosugi, Yoshiko; Sakabe, Ayaka; Takahashi, Kenshi; Miyata, Akira

    2018-04-01

    Season-long methane (CH4) exchange was observed in a rice paddy field in central Japan (Kanto Region) using the eddy covariance technique to clarify the variations in environmental controls on CH4 exchange in different stages of cultivation. Before heading of rice plant, the CH4 emission depended on wind speed and soil temperature. The soil temperature dependence can be due to an increase in CH4 production, higher molecular diffusion, and higher conductance within rice plant at higher soil temperature. An occurrence of ebullitive emission was also suggested from the wind speed dependence. After heading was completed, relative humidity and water temperature influenced CH4 emission. The amplitude of the diurnal variation in emission increased from 0.03 μmolm-2s-1 in the late pre-heading stage to 0.13 μmolm-2s-1 in the post-heading stage. Induced convective throughflow within the rice aerenchyma after the change in plant structure was attributable to this variation in environmental controls after the heading. After drainage, CH4 emission was confined to short periods after strong rain events. The water level controlled the timing of emission, most likely by influencing the diffusion efficiency from the anoxic soil to the atmosphere and CH4 oxidation in the surface oxic zone. The variation in the dominant transport pathway needs to be accounted for in terrestrial ecosystem models to accurately predict CH4 emission from rice paddies.

  15. Gate-Tunable Spin Exchange Interactions and Inversion of Magnetoresistance in Single Ferromagnetic ZnO Nanowires.

    Science.gov (United States)

    Modepalli, Vijayakumar; Jin, Mi-Jin; Park, Jungmin; Jo, Junhyeon; Kim, Ji-Hyun; Baik, Jeong Min; Seo, Changwon; Kim, Jeongyong; Yoo, Jung-Woo

    2016-04-26

    Electrical control of ferromagnetism in semiconductor nanostructures offers the promise of nonvolatile functionality in future semiconductor spintronics. Here, we demonstrate a dramatic gate-induced change of ferromagnetism in ZnO nanowire (NW) field-effect transistors (FETs). Ferromagnetism in our ZnO NWs arose from oxygen vacancies, which constitute deep levels hosting unpaired electron spins. The magnetic transition temperature of the studied ZnO NWs was estimated to be well above room temperature. The in situ UV confocal photoluminescence (PL) study confirmed oxygen vacancy mediated ferromagnetism in the studied ZnO NW FET devices. Both the estimated carrier concentration and temperature-dependent conductivity reveal the studied ZnO NWs are at the crossover of the metal-insulator transition. In particular, gate-induced modulation of the carrier concentration in the ZnO NW FET significantly alters carrier-mediated exchange interactions, which causes even inversion of magnetoresistance (MR) from negative to positive values. Upon sweeping the gate bias from -40 to +50 V, the MRs estimated at 2 K and 2 T were changed from -11.3% to +4.1%. Detailed analysis on the gate-dependent MR behavior clearly showed enhanced spin splitting energy with increasing carrier concentration. Gate-voltage-dependent PL spectra of an individual NW device confirmed the localization of oxygen vacancy-induced spins, indicating that gate-tunable indirect exchange coupling between localized magnetic moments played an important role in the remarkable change of the MR.

  16. Replica exchange enveloping distribution sampling (RE-EDS): A robust method to estimate multiple free-energy differences from a single simulation.

    Science.gov (United States)

    Sidler, Dominik; Schwaninger, Arthur; Riniker, Sereina

    2016-10-21

    In molecular dynamics (MD) simulations, free-energy differences are often calculated using free energy perturbation or thermodynamic integration (TI) methods. However, both techniques are only suited to calculate free-energy differences between two end states. Enveloping distribution sampling (EDS) presents an attractive alternative that allows to calculate multiple free-energy differences in a single simulation. In EDS, a reference state is simulated which "envelopes" the end states. The challenge of this methodology is the determination of optimal reference-state parameters to ensure equal sampling of all end states. Currently, the automatic determination of the reference-state parameters for multiple end states is an unsolved issue that limits the application of the methodology. To resolve this, we have generalised the replica-exchange EDS (RE-EDS) approach, introduced by Lee et al. [J. Chem. Theory Comput. 10, 2738 (2014)] for constant-pH MD simulations. By exchanging configurations between replicas with different reference-state parameters, the complexity of the parameter-choice problem can be substantially reduced. A new robust scheme to estimate the reference-state parameters from a short initial RE-EDS simulation with default parameters was developed, which allowed the calculation of 36 free-energy differences between nine small-molecule inhibitors of phenylethanolamine N-methyltransferase from a single simulation. The resulting free-energy differences were in excellent agreement with values obtained previously by TI and two-state EDS simulations.

  17. Solvent exchange in a metal-organic framework single crystal monitored by dynamic in situ X-ray diffraction.

    Science.gov (United States)

    Cox, Jordan M; Walton, Ian M; Bateman, Gage; Benson, Cassidy A; Mitchell, Travis; Sylvester, Eric; Chen, Yu Sheng; Benedict, Jason B

    2017-08-01

    Understanding the processes by which porous solid-state materials adsorb and release guest molecules would represent a significant step towards developing rational design principles for functional porous materials. To elucidate the process of liquid exchange in these materials, dynamic in situ X-ray diffraction techniques have been developed which utilize liquid-phase chemical stimuli. Using these time-resolved diffraction techniques, the ethanol solvation process in a flexible metal-organic framework [Co(AIP)(bpy) 0.5 (H 2 O)]·2H 2 O was examined. The measurements provide important insight into the nature of the chemical transformation in this system including the presence of a previously unreported neat ethanol solvate structure.

  18. Optimal Portfolio Selection in Ex Ante Stock Price Bubble and Furthermore Bubble Burst Scenario from Dhaka Stock Exchange with Relevance to Sharpe’s Single Index Model

    Directory of Open Access Journals (Sweden)

    Javed Bin Kamal

    2012-09-01

    Full Text Available The paper aims at constructing an optimal portfolio by applying Sharpe’s single index model of capital asset pricing in different scenarios, one is ex ante stock price bubble scenario and stock price bubble and bubble burst is second scenario. Here we considered beginning of year 2010 as rise of stock price bubble in Dhaka Stock Exchange. Hence period from 2005 -2009 is considered as ex ante stock price bubble period. Using DSI (All share price index in Dhaka Stock Exchange as market index and considering daily indices for the March 2005 to December 2009 period, the proposed method formulates a unique cut off point (cut off rate of return and selects stocks having excess of their expected return over risk-free rate of return surpassing this cut-off point. Here, risk free rate considered to be 8.5% per annum (Treasury bill rate in 2009. Percentage of an investment in each of the selected stocks is then decided on the basis of respective weights assigned to each stock depending on respective ‘β’ value, stock movement variance representing unsystematic risk, return on stock and risk free return vis-à-vis the cut off rate of return. Interestingly, most of the stocks selected turned out to be bank stocks. Again we went for single index model applied to same stocks those made to the optimum portfolio in ex ante stock price bubble scenario considering data for the period of January 2010 to June 2012. We found that all stocks failed to make the pass Single Index Model criteria i.e. excess return over beta must be higher than the risk free rate. Here for the period of 2010 to 2012, the risk free rate considered to be 11.5 % per annum (Treasury bill rate during 2012.

  19. Centrifugal multiplexing fixed-volume dispenser on a plastic lab-on-a-disk for parallel biochemical single-end-point assays.

    Science.gov (United States)

    La, Moonwoo; Park, Sang Min; Kim, Dong Sung

    2015-01-01

    In this study, a multiple sample dispenser for precisely metered fixed volumes was successfully designed, fabricated, and fully characterized on a plastic centrifugal lab-on-a-disk (LOD) for parallel biochemical single-end-point assays. The dispenser, namely, a centrifugal multiplexing fixed-volume dispenser (C-MUFID) was designed with microfluidic structures based on the theoretical modeling about a centrifugal circumferential filling flow. The designed LODs were fabricated with a polystyrene substrate through micromachining and they were thermally bonded with a flat substrate. Furthermore, six parallel metering and dispensing assays were conducted at the same fixed-volume (1.27 μl) with a relative variation of ±0.02 μl. Moreover, the samples were metered and dispensed at different sub-volumes. To visualize the metering and dispensing performances, the C-MUFID was integrated with a serpentine micromixer during parallel centrifugal mixing tests. Parallel biochemical single-end-point assays were successfully conducted on the developed LOD using a standard serum with albumin, glucose, and total protein reagents. The developed LOD could be widely applied to various biochemical single-end-point assays which require different volume ratios of the sample and reagent by controlling the design of the C-MUFID. The proposed LOD is feasible for point-of-care diagnostics because of its mass-producible structures, reliable metering/dispensing performance, and parallel biochemical single-end-point assays, which can identify numerous biochemical.

  20. Can the single-breath helium dilution method predict lung volumes as measured by whole-body plethysmography?

    Directory of Open Access Journals (Sweden)

    Patrícia Chaves Coertjens

    2013-12-01

    Full Text Available OBJECTIVE: To compare TLC and RV values obtained by the single-breath helium dilution (SBHD method with those obtained by whole-body plethysmography (WBP in patients with normal lung function, patients with obstructive lung disease (OLD, and patients with restrictive lung disease (RLD, varying in severity, and to devise equations to estimate the SBHD results.METHODS: This was a retrospective cross-sectional study involving 169 individuals, of whom 93 and 49 presented with OLD and RLD, respectively, the remaining 27 having normal lung function. All patients underwent spirometry and lung volume measurement by both methods.RESULTS: TLC and RV were higher by WBP than by SBHD. The discrepancy between the methods was more pronounced in the OLD group, correlating with the severity of airflow obstruction. In the OLD group, the correlation coefficient of the comparison between the two methods was 0.57 and 0.56 for TLC and RV, respectively (p < 0.001 for both. We used regression equations, adjusted for the groups studied, in order to predict the WBP values of TLC and RV, using the corresponding SBHD values. It was possible to create regression equations to predict differences in TLC and RV between the two methods only for the OLD group. The TLC and RV equations were, respectively, ∆TLCWBP-SBHD in L = 5.264 − 0.060 × FEV1/FVC (r2= 0.33; adjusted r2 = 0.32 and ∆RVWBP-SBHD in L = 4.862 − 0.055 × FEV1/FVC (r2= 0.31; adjusted r2 = 0.30.CONCLUSIONS: The correction of TLC and RV results obtained by SBHD can improve the accuracy of this method for assessing lung volumes in patients with OLD. However, additional studies are needed in order to validate these equations.

  1. Laser Processed Heat Exchangers

    Science.gov (United States)

    Hansen, Scott

    2017-01-01

    The Laser Processed Heat Exchanger project will investigate the use of laser processed surfaces to reduce mass and volume in liquid/liquid heat exchangers as well as the replacement of the harmful and problematic coatings of the Condensing Heat Exchangers (CHX). For this project, two scale unit test articles will be designed, manufactured, and tested. These two units are a high efficiency liquid/liquid HX and a high reliability CHX.

  2. AN ANALYSIS OF SINGLE INDEX MARKET MODEL AND ITS ASSUMPTIONS’ VALIDITY IN ESTIMATING SECTOR BETAS AT ISTANBUL STOCK EXCHANGE

    Directory of Open Access Journals (Sweden)

    KORAY KAYALIDERE

    2013-06-01

    Full Text Available This study aims examination of statistical properties of single index market model. Moreover, the fulfillment degree of basic assumptions related with the model is researched. Daily, weekly, and monthly logarithmic industry portfolio returns covering 2000-2012 period are used and ISE-100 index is chosen to represent the market portfolio. Main goals of this research are to investigate statistical significance of the sector betas, the accuracy of the model specification, ARCH effect, and autocorrelation and heteroscedasticity problems. It can be said that single index model based on daily return interval does not satisfy econometrical and statistical assumptions. Furthermore, it is observed that the fulfillment degree of basic assumptions increases as the return interval gets wider.

  3. Tidal volume single breath washout of two tracer gases--a practical and promising lung function test.

    Science.gov (United States)

    Singer, Florian; Stern, Georgette; Thamrin, Cindy; Fuchs, Oliver; Riedel, Thomas; Gustafsson, Per; Frey, Urs; Latzin, Philipp

    2011-03-10

    Small airway disease frequently occurs in chronic lung diseases and may cause ventilation inhomogeneity (VI), which can be assessed by washout tests of inert tracer gas. Using two tracer gases with unequal molar mass (MM) and diffusivity increases specificity for VI in different lung zones. Currently washout tests are underutilised due to the time and effort required for measurements. The aim of this study was to develop and validate a simple technique for a new tidal single breath washout test (SBW) of sulfur hexafluoride (SF(6)) and helium (He) using an ultrasonic flowmeter (USFM). The tracer gas mixture contained 5% SF(6) and 26.3% He, had similar total MM as air, and was applied for a single tidal breath in 13 healthy adults. The USFM measured MM, which was then plotted against expired volume. USFM and mass spectrometer signals were compared in six subjects performing three SBW. Repeatability and reproducibility of SBW, i.e., area under the MM curve (AUC), were determined in seven subjects performing three SBW 24 hours apart. USFM reliably measured MM during all SBW tests (n = 60). MM from USFM reflected SF(6) and He washout patterns measured by mass spectrometer. USFM signals were highly associated with mass spectrometer signals, e.g., for MM, linear regression r-squared was 0.98. Intra-subject coefficient of variation of AUC was 6.8%, and coefficient of repeatability was 11.8%. The USFM accurately measured relative changes in SF(6) and He washout. SBW tests were repeatable and reproducible in healthy adults. We have developed a fast, reliable, and straightforward USFM based SBW method, which provides valid information on SF(6) and He washout patterns during tidal breathing.

  4. Tidal volume single breath washout of two tracer gases--a practical and promising lung function test.

    Directory of Open Access Journals (Sweden)

    Florian Singer

    Full Text Available BACKGROUND: Small airway disease frequently occurs in chronic lung diseases and may cause ventilation inhomogeneity (VI, which can be assessed by washout tests of inert tracer gas. Using two tracer gases with unequal molar mass (MM and diffusivity increases specificity for VI in different lung zones. Currently washout tests are underutilised due to the time and effort required for measurements. The aim of this study was to develop and validate a simple technique for a new tidal single breath washout test (SBW of sulfur hexafluoride (SF(6 and helium (He using an ultrasonic flowmeter (USFM. METHODS: The tracer gas mixture contained 5% SF(6 and 26.3% He, had similar total MM as air, and was applied for a single tidal breath in 13 healthy adults. The USFM measured MM, which was then plotted against expired volume. USFM and mass spectrometer signals were compared in six subjects performing three SBW. Repeatability and reproducibility of SBW, i.e., area under the MM curve (AUC, were determined in seven subjects performing three SBW 24 hours apart. RESULTS: USFM reliably measured MM during all SBW tests (n = 60. MM from USFM reflected SF(6 and He washout patterns measured by mass spectrometer. USFM signals were highly associated with mass spectrometer signals, e.g., for MM, linear regression r-squared was 0.98. Intra-subject coefficient of variation of AUC was 6.8%, and coefficient of repeatability was 11.8%. CONCLUSION: The USFM accurately measured relative changes in SF(6 and He washout. SBW tests were repeatable and reproducible in healthy adults. We have developed a fast, reliable, and straightforward USFM based SBW method, which provides valid information on SF(6 and He washout patterns during tidal breathing.

  5. A simplified fracture network model for studying the efficiency of a single well semi open loop heat exchanger in fractured crystalline rock

    Science.gov (United States)

    de La Bernardie, Jérôme; de Dreuzy, Jean-Raynald; Bour, Olivier; Thierion, Charlotte; Ausseur, Jean-Yves; Lesuer, Hervé; Le Borgne, Tanguy

    2016-04-01

    Geothermal energy is a renewable energy source particularly attractive due to associated low greenhouse gas emission rates. Crystalline rocks are in general considered of poor interest for geothermal applications at shallow depths (energy storage at these shallow depths is still remaining very challenging because of the complexity of fractured media. The purpose of this study is to test the possibility of efficient thermal energy storage in shallow fractured rocks with a single well semi open loop heat exchanger (standing column well). For doing so, a simplified numerical model of fractured media is considered with few fractures. Here we present the different steps for building the model and for achieving the sensitivity analysis. First, an analytical and dimensional study on the equations has been achieved to highlight the main parameters that control the optimization of the system. In a second step, multiphysics software COMSOL was used to achieve numerical simulations in a very simplified model of fractured media. The objective was to test the efficiency of such a system to store and recover thermal energy depending on i) the few parameters controlling fracture network geometry (size and number of fractures) and ii) the frequency of cycles used to store and recover thermal energy. The results have then been compared to reference shallow geothermal systems already set up for porous media. Through this study, relationships between structure, heat exchanges and storage may be highlighted.

  6. USE OF SINGLE-MINUTE EXCHANGE OF DIE – SMED – AS A STRATEGY TO INCREASE PRODUCTIVITY IN A PLASTIC BOTTLE LABELER

    Directory of Open Access Journals (Sweden)

    Teonas Bartz

    2012-12-01

    Full Text Available The increase in the production and sale of food products stored in plastic containers, which serve different markets, caused the company researched departed in search of new concepts to increase the productivity of production equipment. With the increase of productivity, there is greater flexibility in planning and scheduling of production and exchange of tools. The implementation of the methodology of Single-Minute Exchange of Die – SMED reduces the setup time of equipment, maximizing the period of machine operation. With this the company more flexible production process and can reduce production batches, increasing operating rates, productivity and competitiveness of organizations. In this paper, we present the steps necessary for the implementation of the SMED in a labeling machine for plastic bottles. To this end, there were activities analysis, suggestions for improvements in machinery and procedures, timing of the steps before and after the improvements implemented and analyzes of the times obtained. After that, we obtained a significant reduction in setup time machine studied.

  7. Single particle electron microscopy analysis of the bovine anion exchanger 1 reveals a flexible linker connecting the cytoplasmic and membrane domains.

    Directory of Open Access Journals (Sweden)

    Jiansen Jiang

    Full Text Available Anion exchanger 1 (AE1 is the major erythrocyte membrane protein that mediates chloride/bicarbonate exchange across the erythrocyte membrane facilitating CO₂ transport by the blood, and anchors the plasma membrane to the spectrin-based cytoskeleton. This multi-protein cytoskeletal complex plays an important role in erythrocyte elasticity and membrane stability. An in-frame AE1 deletion of nine amino acids in the cytoplasmic domain in a proximity to the membrane domain results in a marked increase in membrane rigidity and ovalocytic red cells in the disease Southeast Asian Ovalocytosis (SAO. We hypothesized that AE1 has a flexible region connecting the cytoplasmic and membrane domains, which is partially deleted in SAO, thus causing the loss of erythrocyte elasticity. To explore this hypothesis, we developed a new non-denaturing method of AE1 purification from bovine erythrocyte membranes. A three-dimensional (3D structure of bovine AE1 at 2.4 nm resolution was obtained by negative staining electron microscopy, orthogonal tilt reconstruction and single particle analysis. The cytoplasmic and membrane domains are connected by two parallel linkers. Image classification demonstrated substantial flexibility in the linker region. We propose a mechanism whereby flexibility of the linker region plays a critical role in regulating red cell elasticity.

  8. Molecular beam study of the mechanism of catalyzed hydrogen--deuterium exchange on platinum single crystal surfaces

    International Nuclear Information System (INIS)

    Bernasek, S.L.; Somorjai, G.A.

    1975-01-01

    The hydrogen--deuterium exchange reaction was studied by molecular beam scattering on low and high Miller index crystal faces of platinum in the surface temperature range of 300--1300degreeK. Under the condition of the experiments which put strict limitation on the residence time of the detected molecules, the reaction product, HD, was readily detectable from the high Miller index, stepped surfaces (integrated reaction probability, defined as total desorbed HD flux divided by D 2 flux, is approx.10/sup -1/) while HD formation was below the limit of detectability on the Pt(111) low Miller index surface (reaction probability 2 beam pressure and half-order in H 2 background pressure. The absence of beam kinetic energy dependence of the rate indicates that the molecular adsorption does not require activation energy. The surface is able to store a sufficiently large concentration of atoms which react with the molecules by a two-branch mechanism. The rate constants for this two-branch mechanism were determined under conditions of constant H atom coverage, reducing the bimolecular reaction to a pseudo-first-order reaction. At lower temperatures ( 1 = (2plus-or-minus1) times10 5 exp(-4.5plus-or-minus0.5 kcal/RT) sec/sup -1/. The rate determining step appears to be the diffusion of the D 2 molecule on the surface to a step site where HD is formed via a three-center (atom--molecule) reaction, or via a two-center (atom--atom) reaction subsequent to D 2 dissociation at the step. At higher temperatures (>600degreeK) the reaction between an adsorbed H atom and an incident D 2 gas molecule competes with the low temperature branch. The rate constant for this branch is k 2 = (1plus-or-minus2) times10 2 exp(-0.6plus-or-minus0.3 kcal/RT) sec/sup -1/

  9. Anion-exchange and anthracene-encapsulation within copper(II) and manganese(II)-triazole metal-organic confined space in a single crystal-to-single crystal transformation fashion.

    Science.gov (United States)

    Liu, Ju-Yan; Wang, Qian; Zhang, Li-Jun; Yuan, Bin; Xu, Yao-Yao; Zhang, Xin; Zhao, Cong-Ying; Wang, Dan; Yuan, Yue; Wang, Ying; Ding, Bin; Zhao, Xiao-Jun; Yue, Min Min

    2014-06-16

    A new multidentate ligand 1-(9-(1H-1,2,4-triazol-1-yl)anthracen-10-yl)-1H-1,2,4-triazole (tatrz) was designed and synthesized. Using tatrz as a building block, three novel coordination frameworks, namely, {[Cu(tatrz)2(NO3)2]·(CH3OH)·4H2O}n (1), {[Cu(tatrz)2(H2O)2](BF4)2}n (2), and [Mn(tatrz)2(SCN)2(CH3OH)]·2H2O (3) can be isolated. Anion-exchange experiment indicates that NO3(-) anions in the two-dimensional (2D) copper framework of 1 can be completely exchanged by ClO4(-) in an irreversible single crystal-to-single crystal (SC-SC) transformation fashion, as evidenced by the anion-exchange products of {[Cu(tatrz)2(H2O)2](ClO4)2·4CH3OH} (1a). Further, if 1a was employed as a precursor in N,N-dimethylformamide (DMF), an isomorphic solvate of {[Cu(tatrz)2(DMF)2](ClO4)2·2H2O}n (1b) can be generated during the reversible dynamic transformation process. When 1 was immersed in CH3OH, a distinct 2D layer {[Cu(tatrz)2(NO3)2]·4.4CH3OH·0.6H2O}n (1c) was isolated. Interestingly, the solvent-exchange conversion is also invertible between 1 and 1c, which exhibits spongelike dynamic behavior with retention of crystalline integrity. If the 2-fold interpenetrating three-dimensional (3D) framework 2 is selected, it can be transformed into another 2-fold interpenetrating 3D framework {[Cu(tatrz)2(H2O)2](ClO4)2·5.56H2O}n (2a) in a reversible SC-SC transformation fashion. However, when the light yellow crystals of mononuclear complex 3 were exposed to trichloromethane containing aromatic organic anthracene (atan), through our careful observation, the crystals of 3 were dissolved and reassembled into dark brown crystals of 2D crystalline coordination framework {[Mn(tatrz)2(SCN)2]·(atan)}n (3a). X-ray diffraction revealed that in 3a, atan acting as an organic template was encapsulated in the confined space of the 2D grid. Luminescent measurements illustrate that 3a is the first report of multidimensional polymers based on triazole derivatives as luminescent probes of Mg(2+).

  10. Different body fluid volumes measured by single- and multi-frequency bioelectrical impedance analyzers in overweight/obese renal patients.

    Science.gov (United States)

    Kusztal, Mariusz; Dzierżek, Przemysław; Gołębiowski, Tomasz; Weyde, Wacław; Klinger, Marian

    2015-05-17

    Bioelectrical impedance analysis (BIA) is an affordable, non-invasive and fast alternative method to assess body composition. The purpose of this study was to compare two different tetrapolar BIA devices for estimating body fluid volumes and body cell mass (BCM) in a clinical setting among patients with kidney failure. All double measurements were performed by multi-frequency (MF) and single-frequency (SF) BIA analyzers: a Body Composition Monitor (Fresenius Medical Care, Germany) and BIA-101 (Akern, Italy), respectively. All procedures were conducted according to the manufacturers' instructions (dedicated electrodes, measurement sites, positions, etc). Total body water (TBW), extracellular water (ECW), intracellular water (ICW) and BCM were compared. The study included 39 chronic kidney disease patients (stage III-V) with a mean age of 45.8 ± 8 years (21 men and 18 women) who had a wide range of BMI [17-34 kg/m2 (mean 26.6 ±5)]. A comparison of results from patients with BMI obese renal patients.

  11. Characterization of Distinct Astrocytic Populations Responding with Different Volume Changes to Oxygen-Glucose Deprivation: 3d Confocal Morphometry And Single-Cell Gene Expression Profilig

    Czech Academy of Sciences Publication Activity Database

    Benešová, Jana; Rusňáková, Vendula; Honsa, Pavel; Pivoňková, Helena; Kubista, Mikael; Anděrová, Miroslava

    2011-01-01

    Roč. 59, Supplement 1 (2011), S126-S126 ISSN 0894-1491. [European meeting on Glial Cells in Health and Disease /10./. 13.09.2011-13.09.2011, Prague] Institutional research plan: CEZ:AV0Z50390703; CEZ:AV0Z50520701 Keywords : cell volume regulation * single-cell PCR profiling * ischemia Subject RIV: FH - Neurology

  12. Single crystal EPR of the mixed-ligand complex of copper(II) with L-glutamic acid and 1,10-phenanthroline: a study on the narrowing of the hyperfine structure by exchange.

    Science.gov (United States)

    Neuman, Nicolás I; Franco, Vanina G; Ferroni, Felix M; Baggio, Ricardo; Passeggi, Mario C G; Rizzi, Alberto C; Brondino, Carlos D

    2012-12-20

    We report an EPR study at X- and Q-bands of polycrystalline and single crystal samples of the mixed copper(II) complex with L-glutamic acid (glu) and 1,10-phenantroline (phen), [Cu(glu)(phen)(H(2)O)](+) NO(3)(-)·2(H(2)O). The polycrystalline sample spectrum at Q-band showed well resolved g(∥ )and g(⊥) features and partially solved hyperfine structure at g(∥), typical for weakly exchange coupled systems. This is confirmed from the angular variation of the EPR spectra which shows for certain magnetic field orientations a partially solved hyperfine structure characteristic of weak exchange, whereas a single Lorentzian line corresponding to strong exchange is observed for others. Analysis and simulation of the single crystal EPR spectra were performed using the random frequency modulation model of Anderson. Numerical simulations of the angular variation of the EPR spectra showed that the narrowing of the hyperfine structure is due to an exchange-mediated mechanism in which transitions between any pair of lines are equally likely. The exchange interaction responsible for this process is mediated by hydrophobic interactions between two phen molecules and a mixed chemical path of the type CuA-O(ap)H···O-C-O(eq)-CuB, for which we evaluated an average isotropic exchange parameter |J| ≈ 25 × 10(-4) cm(-1).

  13. Enhancing the blocking temperature in single-molecule magnets by incorporating 3d-5d exchange interactions

    DEFF Research Database (Denmark)

    Pedersen, Kasper Søndergaard; Schau-Magnussen, Magnus; Bendix, Jesper

    2010-01-01

    We report the first single-molecule magnet (SMM) to incorporate the [Os(CN)(6)](3-) moiety. The compound (1) has a trimeric, cyanide-bridged Mn(III)-Os(III)-Mn(III) skeleton in which Mn(III) designates a [Mn(5-Brsalen)(MeOH)](+) unit (5-Brsalen=N,N'-ethylenebis(5-bromosalicylideneiminato)). X......-ray crystallographic experiments reveal that 1 is isostructural with the Mn(III)-Fe(III)-Mn(III) analogue (2). Both compounds exhibit a frequency-dependent out-of-phase ¿''(T) alternating current (ac) susceptibility signal that is suggestive of SMM behaviour. From the Arrhenius expression, the effective barrier for 1...... for the design of a new generation of SMMs with enhanced SMM properties....

  14. Single-beat versus multibeat real-time 3D echocardiography for assessing left ventricular volumes and ejection fraction: a comparison study with cardiac magnetic resonance.

    Science.gov (United States)

    Macron, Laurent; Lim, Pascal; Bensaid, Alexandre; Nahum, Julien; Dussault, Caroline; Mitchell-Heggs, Laurens; Dubois-Randé, Jean-Luc; Deux, Jean-François; Gueret, Pascal

    2010-07-01

    Real-time 3-dimensional echocardiography (RT3DE) is superior to 2D echocardiography in assessing left ventricular (LV) volumes and ejection fraction (EF), but its feasibility is limited by multibeat acquisition, which requires an optimal breath-hold and a regular heart rhythm. We sought to evaluate the accuracy and feasibility of single- and 2-beat RT3DE for LV volume and EF assessment. Sixty-six consecutive patients referred for cardiac magnetic resonance (CMR) underwent RT3DE and CMR on the same day. Of the 50 patients (age, 59+/-18 years; 68%men; 42% coronary artery disease; LVEF=49+/-14%; limits, 14% to 76%) with an adequate RT3DE image quality, accuracy for LV volumes and EF measurements of single- and 2-beat modalities were compared with the conventional 4-beat acquisition and CMR. Correlations with CMR for LV end-diastolic volume (161+/-59 mL, r=0.93 to 0.94) and end-systolic volume (86+/-56 mL, r=0.93 to 0.96) were excellent regardless of the number of cardiac cycles used. However, because of the low temporal resolution (7+/-2 volumes per second), single-beat underestimated LVEF (bias, -5+/-8%) with greater bias than 2-beat (bias, 1+/-6%, P<0.001) and 4-beat (bias, 3+/-7%, P<0.001) modalities. Interestingly, 2-beat provided accuracy similar to 4-beat for end-diastolic volume (bias, -17+/-21 mL versus -15+/-23 mL), end-systolic volume (bias, -9+/-16 mL versus -12+/-17 mL), and LVEF (bias, 1+/-6% versus 3+/-7%) measurements, but fewer stitching artifacts were observed with 2- than 4-beat modalities (3% versus 30%). Compared with conventional multibeat acquisitions, 2-beat modality provides similar accuracy in LV volume and EF measurements and should be preferred due to fewer stitching artifacts. In contrast, the temporal resolution of single-beat modality appears insufficient to provide an accurate estimation of LVEF.

  15. Transforming single domain magnetic CoFe{sub 2}O{sub 4} nanoparticles from hydrophobic to hydrophilic by novel mechanochemical ligand exchange

    Energy Technology Data Exchange (ETDEWEB)

    Munjal, Sandeep; Khare, Neeraj, E-mail: nkhare@physics.iitd.ernet.in [Indian Institute of Technology Delhi, Department of Physics (India)

    2017-01-15

    Single-phase uniform-sized (~9 nm) cobalt ferrite (CFO) nanoparticles have been synthesized by hydrothermal synthesis using oleic acid as a surfactant. The as-synthesized oleic acid-coated CFO (OA-CFO) nanoparticles were well dispersible in nonpolar solvents but not dispersible in water. The OA-CFO nanoparticles have been successfully transformed to highly water-dispersible citric acid-coated CFO (CA-CFO) nanoparticles using a novel single-step ligand exchange process by mechanochemical milling, in which small chain citric acid molecules replace the original large chain oleic acid molecules available on CFO nanoparticles. The OA-CFO nanoparticle’s hexane solution and CA-CFO nanoparticle’s water solution remain stable even after 6 months and show no agglomeration and their dispersion stability was confirmed by zeta-potential measurements. The contact angle measurement shows that OA-CFO nanoparticles are hydrophobic whereas CA-CFO nanoparticles are superhydrophilic in nature. The potentiality of as-synthesized OA-CFO and mechanochemically transformed CA-CFO nanoparticles for the demulsification of highly stabilized water-in-oil and oil-in-water emulsions has been demonstrated.

  16. Combining microscopic and macroscopic probes to untangle the single-ion anisotropy and exchange energies in an S =1 quantum antiferromagnet

    Science.gov (United States)

    Brambleby, Jamie; Manson, Jamie L.; Goddard, Paul A.; Stone, Matthew B.; Johnson, Roger D.; Manuel, Pascal; Villa, Jacqueline A.; Brown, Craig M.; Lu, Helen; Chikara, Shalinee; Zapf, Vivien; Lapidus, Saul H.; Scatena, Rebecca; Macchi, Piero; Chen, Yu-sheng; Wu, Lai-Chin; Singleton, John

    2017-04-01

    The magnetic ground state of the quasi-one-dimensional spin-1 antiferromagnetic chain is sensitive to the relative sizes of the single-ion anisotropy (D ) and the intrachain (J ) and interchain (J') exchange interactions. The ratios D /J and J'/J dictate the material's placement in one of three competing phases: a Haldane gapped phase, a quantum paramagnet, and an X Y -ordered state, with a quantum critical point at their junction. We have identified [Ni (HF2) (pyz) 2] SbF6 , where pyz = pyrazine, as a rare candidate in which this behavior can be explored in detail. Combining neutron scattering (elastic and inelastic) in applied magnetic fields of up to 10 tesla and magnetization measurements in fields of up to 60 tesla with numerical modeling of experimental observables, we are able to obtain accurate values of all of the parameters of the Hamiltonian [D =13.3 (1 ) K, J =10.4 (3 ) K, and J'=1.4 (2 ) K], despite the polycrystalline nature of the sample. Density-functional theory calculations result in similar couplings (J =9.2 K, J'=1.8 K) and predict that the majority of the total spin population resides on the Ni(II) ion, while the remaining spin density is delocalized over both ligand types. The general procedures outlined in this paper permit phase boundaries and quantum-critical points to be explored in anisotropic systems for which single crystals are as yet unavailable.

  17. Probing the regional distribution of pulmonary gas exchange through single-breath gas- and dissolved-phase 129Xe MR imaging.

    Science.gov (United States)

    Kaushik, S Sivaram; Freeman, Matthew S; Cleveland, Zackary I; Davies, John; Stiles, Jane; Virgincar, Rohan S; Robertson, Scott H; He, Mu; Kelly, Kevin T; Foster, W Michael; McAdams, H Page; Driehuys, Bastiaan

    2013-09-01

    Although some central aspects of pulmonary function (ventilation and perfusion) are known to be heterogeneous, the distribution of diffusive gas exchange remains poorly characterized. A solution is offered by hyperpolarized 129Xe magnetic resonance (MR) imaging, because this gas can be separately detected in the lung's air spaces and dissolved in its tissues. Early dissolved-phase 129Xe images exhibited intensity gradients that favored the dependent lung. To quantitatively corroborate this finding, we developed an interleaved, three-dimensional radial sequence to image the gaseous and dissolved 129Xe distributions in the same breath. These images were normalized and divided to calculate "129Xe gas-transfer" maps. We hypothesized that, for healthy volunteers, 129Xe gas-transfer maps would retain the previously observed posture-dependent gradients. This was tested in nine subjects: when the subjects were supine, 129Xe gas transfer exhibited a posterior-anterior gradient of -2.00 ± 0.74%/cm; when the subjects were prone, the gradient reversed to 1.94 ± 1.14%/cm (P gas-transfer maps also exhibited significant heterogeneity, as measured by the coefficient of variation, that correlated with subject total lung capacity (r = 0.77, P = 0.015). Gas-transfer intensity varied nonmonotonically with slice position and increased in slices proximal to the main pulmonary arteries. Despite substantial heterogeneity, the mean gas transfer for all subjects was 1.00 ± 0.01 while supine and 1.01 ± 0.01 while prone (P = 0.25), indicating good "matching" between gas- and dissolved-phase distributions. This study demonstrates that single-breath gas- and dissolved-phase 129Xe MR imaging yields 129Xe gas-transfer maps that are sensitive to altered gas exchange caused by differences in lung inflation and posture.

  18. Effect of partial volume correction on muscarinic cholinergic receptor imaging with single-photon emission tomography in patients with temporal lobe epilepsy

    International Nuclear Information System (INIS)

    Weckesser, M.; Ziemons, K.; Griessmeier, M.; Sonnenberg, F.; Langen, K.J.; Mueller-Gaertner, H.W.; Hufnagel, A.; Elger, C.E.; Hacklaender, T.; Holschbach, M.

    1997-01-01

    Animal experiments and preliminary results in humans have indicated alterations of hippocampal muscarinic acetylcholine receptors (mAChR) in temporal lobe epilepsy. Patients with temporal lobe epilepsy often present with a reduction in hippocampal volume. The aim of this study was to investigate the influence of hippocampal atrophy on the quantification of mAChR with single photon emission tomography (SPET) in patients with temporal lobe epilepsy. Cerebral uptake of the muscarinic cholinergic antagonist [ 123 I]4-iododexetimide (IDex) was investigated by SPET in patients suffering from temporal lobe epilepsy of unilateral (n=6) or predominantly unilateral (n=1) onset. Regions of interest were drawn on co-registered magnetic resonance images. Hippocampal volume was determined in these regions and was used to correct the SPET results for partial volume effects. A ratio of hippocampal IDex binding on the affected side to that on the unaffected side was used to detect changes in muscarinic cholinergic receptor density. Before partial volume correction a decrease in hippocampal IDex binding on the focus side was found in each patient. After partial volume no convincing differences remained. Our results indicate that the reduction in hippocampal IDex binding in patients with epilepsy is due to a decrease in hippocampal volume rather than to a decrease in receptor concentration. (orig.). With 2 figs., 2 tabs

  19. Single-Sex Education in the 21st Century. Education Policy Brief. Volume 6, Number 9, Fall 2008

    Science.gov (United States)

    Cable, Kelly E.; Spradlin, Terry E.

    2008-01-01

    Single-sex education describes a diverse range of situations, including individual classes, programs after school, required programs, voluntary programs, and programs to remedy gender inequities and encourage cultural and racial pride. This brief addresses the genesis and legality of single-sex classrooms, the merits and critiques of single-sex…

  20. Determination of blood leukocyte concentration with constant volume acquisition on a flow cytometer is comparable to individualized single platform testing with beads as internal reference standard

    DEFF Research Database (Denmark)

    Hansen, Susan; Dahl, Ronald; Hoffmann, Hans Jürgen

    2008-01-01

    Flow cytometers have a constant flow rate. This enables flow cytometers to measure leukocyte concentrations in a determined volume by acquiring data at a fixed rate over a fixed time and is called constant volume acquisition (CVA). The volume aspirated by a FACS Calibur flow cytometer in 4 min...... at a high rate has a median of 163 microl (IQR 156-170) with TruCount tubes. Leukocyte concentrations of 26 healthy volunteers were measured twice on up to four occasions with a Bürker-Türk chamber, by single platform technology (SPT) with TruCount tubes and on the same data set using CVA. Total leukocyte...... concentrations determined by CVA correlated better with measurements in a Bürker-Türk (BT) chamber than with SPT. Concentrations determined with CVA were 1.86% higher than with BT whereas SPT data were 5.35% higher than BT (pconcentrations

  1. Exchange transfusion

    Science.gov (United States)

    ... count in a newborn (neonatal polycythemia) Rh-induced hemolytic disease of the newborn Severe disturbances in body chemistry Severe newborn jaundice ... exchange transfusion was performed to treat. Alternative Names Hemolytic disease - exchange transfusion Patient ... Exchange transfusion - series References Costa ...

  2. Inner-shell spectroscopy and exchange interaction of Rydberg electrons bound by singly and doubly charged Kr and Xe atoms in small clusters

    Energy Technology Data Exchange (ETDEWEB)

    Nagasaka, Masanari; Hatsui, Takaki; Setoyama, Hiroyuki; Ruehl, Eckart [Institute for Molecular Science, Myodaiji, Okazaki 444-8585 (Japan); Kosugi, Nobuhiro, E-mail: kosugi@ims.ac.j [Institute for Molecular Science, Myodaiji, Okazaki 444-8585 (Japan)

    2011-01-15

    Surface-site resolved Kr 3d{sub 5/2}{sup -1}5p and 3d{sub 5/2}{sup -1}6p and Xe 4d{sub 5/2}{sup -1}6p and 4d{sub 5/2}{sup -1}7p Rydberg excited states in small van der Waals Kr and Xe clusters with a mean size of = 15 are investigated by X-ray absorption spectroscopy. Furthermore, surface-site resolved Kr 4s{sup -2}5p, 4s{sup -2}6p, and 4s{sup -1}4p{sup -1}5p shakeup-like Rydberg states in small Kr clusters are investigated by resonant Auger electron spectroscopy. The exchange interaction of the Rydberg electron with the surrounding atoms and the induced polarization of the surrounding atoms in the singly and doubly ionized atoms are deduced from the experimental spectra to analyze different surface-site contributions in small clusters, assuming that the corner, edge, face, and bulk sites have 3, 5-6, 8, and 12 nearest neighbor atoms. These energies are almost proportional to the number of the nearest neighbor atoms. The present analysis indicates that small Kr and Xe clusters with = 15 have an average or mixture structure between the fcc-like cubic and icosahedron-like spherical structures.

  3. A single-institution experience: the integrated vascular surgery residency's effect on fellowship and general surgery resident case volume and diversity.

    Science.gov (United States)

    Carroll, Megan I; Downes, Kathryne; Miladinovic, Branko; Illig, Karl A; Armstrong, Paul A; Back, Martin R; Johnson, Brad L; Shames, Murray L

    2014-01-01

    To determine whether the formation of an integrated vascular surgery residency (0 + 5) has negatively impacted the case volume and diversity of the vascular surgery fellows (5 + 2) and chief general surgeons at the same institution. Operative data from the vascular integrated (0 + 5), independent (5 + 2), and general surgery residencies at a single institution were retrospectively reviewed and analyzed to determine vascular surgery case volumes from 2006-2012. National operative data (Residency Review Committee) were used for comparison of diversity and volume. Standard statistical methods were applied. During this period, the 5 + 2 fellows at our institution performed on average 741 (range, 554-1002) primary cases and 1091 (range, 844-1479) combined primary and secondary cases for the 2-year fellowship. Our integrated residency began in July 2007. Our fellows' primary case volumes remained relatively stable between 2006 and 2011, with a 4% increase in the number of cases, although their total (primary and secondary) case volumes fell 15%; by comparison, the equivalent national 50th percentile rates rose 16% during this time frame. Our institution's general surgery residents performed an average of 116 (range, 56-221) vascular cases individually during their 5-year residency from 2005-2011. From 2006-2011, the total case volume fell only 5%, while the national 50th percentile rate fell 24%. Across all years, however, resident and fellow volumes both continue to be above Accreditation Council for Graduate Medical Education minimum requirements, and the major vascular case volume at our institution in all groups studied remained statistically greater than or equal to the national 50th percentile of cases. Our first integrated resident to graduate finished in June 2012 with 931 total vascular cases and 249 general surgery cases for a total operative experience of 1180 cases during the 5-year residency. Finally, after an 8-year period (2003-2010) in which none of

  4. Reassessing breeding investment in birds: class-wide analysis of clutch volume reveals a single outlying family.

    Science.gov (United States)

    Watson, David M; Anderson, Susan E; Olson, Valerie

    2015-01-01

    Reproductive investment is typically considered in terms of size and number of propagules produced. Compared with a thorough understanding of the overall patterns and ecological correlates of avian clutch size, egg size has received less attention and the total effort invested in laying a clutch of eggs is rarely considered. We used clutch volume as an alternative estimate of reproductive investment and present the first class-level analysis of clutch volume in birds using 1,364 randomly-selected species in 204 families. The relationship between body mass and egg volume was very strong (r2 = 0.946), validating previous studies identifying four families (Apterygidae, Pelecanoidiididae, Sternidae and Dromadidiae) with disproportionately large eggs. Clutch volume was also closely related to body mass (r2 = 0.909) and all but one of the taxa with disproportionately large eggs conformed to the overall relationship, their greater egg dimensions compensated by diminished clutch size. The only family which departed significantly from the relationship between body mass and clutch volume was the mound builders (Megapodiidae)-the only group of birds that do not rely on body heat for incubation. Although previously known for laying large clutches of large eggs containing disproportionately large yolks, the remarkable investment of megapodes in reproduction (more than seven times greater than other birds of comparable mass) has been hitherto overlooked. We consider the evolutionary basis and ecological implications of this finding, suggesting that energetic costs associated with incubation act as an upper limit on reproductive output of other birds. We recommend clutch volume as a sensitive, fine-grained measure of reproductive effort for research at a wide range of scales and advocate further analysis of ecological correlates of clutch volume in birds and amniotes generally.

  5. Radiobiological restrictions and tolerance doses of repeated single-fraction hdr-irradiation of intersecting small liver volumes for recurrent hepatic metastases

    Directory of Open Access Journals (Sweden)

    Wust Peter

    2010-05-01

    Full Text Available Abstract Background To assess radiobiological restrictions and tolerance doses as well as other toxic effects derived from repeated applications of single-fraction high dose rate irradiation of small liver volumes in clinical practice. Methods Twenty patients with liver metastases were treated repeatedly (2 - 4 times at identical or intersecting locations by CT-guided interstitial brachytherapy with varying time intervals. Magnetic resonance imaging using the hepatocyte selective contrast media Gd-BOPTA was performed before and after treatment to determine the volume of hepatocyte function loss (called pseudolesion, and the last acquired MRI data set was merged with the dose distributions of all administered brachytherapies. We calculated the BED (biologically equivalent dose for a single dose d = 2 Gy for different α/β values (2, 3, 10, 20, 100 based on the linear-quadratic model and estimated the tolerance dose for liver parenchyma D90 as the BED exposing 90% of the pseudolesion in MRI. Results The tolerance doses D90 after repeated brachytherapy sessions were found between 22 - 24 Gy and proved only slightly dependent on α/β in the clinically relevant range of α/β = 2 - 10 Gy. Variance analysis showed a significant dependency of D90 with respect to the intervals between the first irradiation and the MRI control (p 90 and the pseudolesion's volume. No symptoms of liver dysfunction or other toxic effects such as abscess formation occurred during the follow-up time, neither acute nor on the long-term. Conclusions Inactivation of liver parenchyma occurs at a BED of approx. 22 - 24 Gy corresponding to a single dose of ~10 Gy (α/β ~ 5 Gy. This tolerance dose is consistent with the large potential to treat oligotopic and/or recurrent liver metastases by CT-guided HDR brachytherapy without radiation-induced liver disease (RILD. Repeated small volume irradiation may be applied safely within the limits of this study.

  6. Best single-slice location to measure visceral adipose tissue on paediatric CT scans and the relationship between anthropometric measurements, gender and VAT volume in children.

    Science.gov (United States)

    O'Connor, Michelle; Ryan, John; Foley, Shane

    2015-10-01

    Visceral adipose tissue (VAT) is a significant risk factor for obesity-related metabolic diseases. This study investigates (1) the best single CT slice location for predicting total abdominal VAT volume in paediatrics and (2) the relationship between waist circumference (WC), sagittal diameter (SD), gender and VAT volume. A random sample of 130 paediatric abdomen CT scans, stratified according to age and gender, was collected. Three readers measured VAT area at each intervertebral level between T12 and S1 using ImageJ analysis (National Institute of Health, Bethesda, MD) software by thresholding -190 to -30 HU and manually segmenting VAT. Single-slice VAT measurements were correlated with total VAT volume to identify the most representative slice. WC and SD were measured at L3-L4 and L4-L5 slices, respectively. Regression analysis was used to evaluate WC, SD and gender as VAT volume predictors. Interviewer and intraviewer reliability were excellent (intraclass correlation coefficient = 0.99). Although VAT measured at multiple slices correlated strongly with abdominal VAT, only one slice in females at L2-L3 and two slices in males at L1-L2 and L5-S1 were strongly correlated across all age groups. Linear regression analysis showed that WC was strongly correlated with VAT volume (beta = 0.970, p VAT measurements are highly reproducible. Measurements performed at L2-L3 in females and L1-L2 or L5-S1 in males were most representative of VAT. WC is indicative of VAT. VAT should be measured at L2-L3 in female children and at either L1-L2 or L5-S1 in males. WC is a strong indicator of VAT in children.

  7. Barter exchanges

    DEFF Research Database (Denmark)

    Sudzina, Frantisek

    Although barter is often perceived as something that proceeded money, barter is still used. The focus of the paper is on barter exchanges. Barter exchanges are used both in developing countries as well as in developed countries (including the U.S.). They are used by both organizations...... and individuals. They usually allow to exchange good but some include also services. Some exchanges allow only for bi-directional barter, i.e. when only two parties are involved in the exchange. But probably most of the barter exchanges use barter money; this makes it easier to exchange goods and services...

  8. Robust semi-automatic segmentation of single- and multichannel MRI volumes through adaptable class-specific representation

    Science.gov (United States)

    Nielsen, Casper F.; Passmore, Peter J.

    2002-05-01

    Segmentation of MRI volumes is complicated by noise, inhomogeneity and partial volume artefacts. Fully or semi-automatic methods often require time consuming or unintuitive initialization. Adaptable Class-Specific Representation (ACSR) is a semi-automatic segmentation framework implemented by the Path Growing Algorithm (PGA), which reduces artefacts near segment boundaries. The user visually defines the desired segment classes through the selection of class templates and the following segmentation process is fully automatic. Good results have previously been achieved with color cryo section segmentation and ACSR has been developed further for the MRI modality. In this paper we present two optimizations for robust ACSR segmentation of MRI volumes. Automatic template creation based on an initial segmentation step using Learning Vector Quantization is applied for higher robustness to noise. Inhomogeneity correction is added as a pre-processing step, comparing the EQ and N3 algorithms. Results based on simulated T1-weighed and multispectral (T1 and T2) MRI data from the BrainWeb database and real data from the Internet Brain Segmentation Repository are presented. We show that ACSR segmentation compares favorably to previously published results on the same volumes and discuss the pros and cons of using quantitative ground truth evaluation compared to qualitative visual assessment.

  9. Ultrasound-guided peripheral deep vein cannulation to perform automated red cell exchange-A pilot study in a single centre.

    Science.gov (United States)

    Putensen, Daniel; Pilcher, Linda; Collier, Dawn; McInerney, Karen

    2016-12-01

    Securing adequate vascular access is essential for a successful apheresis procedure. In most, peripheral access is preferred but it is not always technically possible. Ultrasound-Guided Peripheral Vascular Access (USG-PIVA) is a well-documented technique in the setting of Emergency departments. However, limited data exists reporting its use in the context of automated red cell exchanges (a-RCEx). To assess the effectiveness and feasibility of USG-PIVA to undertake successful a-RCEx. Data was collected prospectively from patients with sickle cell disease and difficult venous access, undergoing a-RCEx at a single centre. The USG-PIVA technique was attempted and data relating to each attempt was collected and analysed. Between April 2014 and July 2015 84 USG-PIVA procedures were performed on 38 patients. 71 USG-PIVA (85%) were successful, 13 (15%) were unsuccessful. Veins successfully cannulated: in the upper arm, basilic (22), brachial (33) and cephalic (2) veins; in the antecubital fossa, basilic (3) and median cubital (7) and in the lower arm, cephalic (2) and radial (2). Cannulas used: Introcan Safety® Braun 22 g (1), 20 g (9) and 18 g (61). Inlet flow rates achieved: 30-60 ml/min (mean 45 ml/min). Depth of veins cannulated: 2-12 mm (mean 5 mm). two complications were observed-one cannula displacement and one nerve injury. No arterial punctures occurred. Central Venous Catheters avoided (49). The US-PIVA method offers an effective alternative to Central Venous Access in patients requiring a-RCEx procedures who lack visual or palpable peripheral access, with minimal complications seen in this series. J. Clin. Apheresis 31:501-506, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  10. Bis-picolinamide Ruthenium(III) Dihalide Complexes: Dichloride-to-Diiodide Exchange Generates Single trans Isomers with High Potency and Cancer Cell Selectivity.

    Science.gov (United States)

    Basri, Aida M; Lord, Rianne M; Allison, Simon J; Rodríguez-Bárzano, Andrea; Lucas, Stephanie J; Janeway, Felix D; Shepherd, Helena J; Pask, Christopher M; Phillips, Roger M; McGowan, Patrick C

    2017-05-05

    A library of new bis-picolinamide ruthenium(III) dihalide complexes of the type [RuX 2 L 2 ] (X=Cl or I, L=picolinamide) have been synthesised and characterised. The complexes exhibit different picolinamide ligand binding modes, whereby one ligand is bound (N,N) and the other bound (N,O). Structural studies revealed a mixture of cis and trans isomers for the [RuCl 2 L 2 ] complexes but upon a halide exchange reaction to yield [RuI 2 L 2 ], only single trans isomers were detected. High cytotoxic activity against human cancer cell lines was observed, with the potencies of some complexes similar to or better than cisplatin. The conversion to [RuI 2 L 2 ] substantially increased the activity towards cancer cell lines by more than twelvefold. The [RuI 2 L 2 ] complexes displayed potent activity against the A2780cis (cisplatin-resistant human ovarian cancer) cell line, with a more than fourfold higher potency than cisplatin. Equitoxic activity was observed against normoxic and hypoxic cancer cells, which indicates the potential to eradicate both the hypoxic and aerobic fractions of solid tumours with similar efficiency. The activity of selected complexes against non-cancer ARPE-19 cells was also tested. The [RuI 2 L 2 ] complexes were found to be more potent than the [RuCl 2 L 2 ] analogues and also more selective towards cancer cells with a selectivity factor in excess of sevenfold. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Comparison of the effect of a single dose of erythromycin with pantoprazole on gastric content volume and acidity in elective general surgery patients

    Directory of Open Access Journals (Sweden)

    Nidhi Bhatia

    2011-01-01

    Full Text Available Introduction: Pulmonary aspiration of gastric contents remains one of the most feared complications of anesthesia. A gastric pH of 2.5 or less and a volume of 25 ml (0.4 ml/kg body weight or more in average adult patients are considered critical factors for the development of pulmonary damage in adults. Materials and Methods: This study compared the efficacy of a single oral dose of erythromycin (a macrolide antibiotic with oral pantoprazole (a proton pump inhibitor on pre-operative gastric fluid volume and pH in a prospective, randomized, double-blind controlled fashion in 80 adult patients (of ASA physical status I and II planned for elective surgery under general anesthesia. Patients were divided into two groups of 40 patients each. The pantoprazole group (Group I received oral pantoprazole 40 mg and the erythromycin group (Group II received oral erythromycin 250 mg at least 1 h prior to the induction of anesthesia. After tracheal intubation, gastric fluid was aspirated via a Salem Sump tube and its volume and pH were measured. Results: Although both erythromycin and pantoprazole decreased the gastric fluid volume to a similar extent, the decrease in gastric fluid acidity by pantoprazole was significantly greater than that by erythromycin. The proportion of patients at risk of pulmonary aspiration according to traditional criteria, i.e. pH ≤2.5 and volume ≥25ml, was lower in the pantoprazole group. Conclusion: Administration of pantoprazole was found to be more useful than a sub-therapeutic dose of erythromycin in decreasing both volume and acidity of gastric content.

  12. Increased single-balloon Foley catheter volume for induction of labor and time to delivery: a systematic review and meta-analysis.

    Science.gov (United States)

    Schoen, Corina N; Saccone, Gabriele; Backley, Sami; Sandberg, Evelien M; Gu, Ning; Delaney, Shani; Berghella, Vincenzo

    2018-04-01

    Induction of labor is a common intervention. The objective was to investigate whether larger Foley catheter volumes for labor induction decrease the total time from induction to delivery. Randomized controlled trials comparing larger single-balloon volumes (60-80 mL) during Foley catheter cervical ripening with usual volume (30 mL) in women undergoing labor induction were identified by searching electronic databases (MEDLINE, Scopus, ClinicalTrials. gov, PROSPERO, EMBASE, Scielo and the Cochrane Central Register of Controlled Trials) from inception through 2017. The primary outcome was mean time from induction to delivery in hours. Secondary outcomes included time from induction to vaginal delivery, delivery within 24 hours, time to Foley expulsion, cesarean section, chorioamnionitis, epidural use, hemorrhage, meconium staining, and neonatal intensive care unit admission. Meta-analysis was performed using the random effects model of DerSimonian and Laird. (PROSPERO CRD42017058885). Seven randomized controlled trials including 1,432 singleton gestations were included in the systematic review. Women randomized to larger volumes of balloon had a significantly shorter time from induction to delivery (mean difference 1.97 hours, 95% CI; -3.88 to -0.06). There was no difference in cesarean section between groups (16% vs. 18%, relative risk 0.84, CI; 0.6 to 1.17). A larger balloon volume was associated with a non-significant decrease in time from induction to delivery in multiparous (mean difference 2.67 hours, CI; -6.1 to 0.76) and nulliparous women (mean difference 1.82 hours, CI; -4.16 to 0.53). Balloon volumes larger than 30 mL during Foley catheter induction reduce total time to delivery by approximately two hours. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  13. Effects of local single and fractionated X-ray doses on rat bone marrow blood flow and red blood cell volume

    International Nuclear Information System (INIS)

    Pitkaenen, M.A.; Hopewell, J.W.

    1985-01-01

    Time and dose dependent changes in blood flow and red blood cell volume were studied in the locally irradiated bone marrow of the rat femur after single and fractionated doses of X-rays. With the single dose of 10 Gy the bone marrow blood flow although initially reduced returned to the control levels by seven months after irradiation. With doses >=15 Gy the blood flow was still significantly reduced at seven months. The total dose levels predicted by the nominal standard dose equation for treatments in three, six or nine fractions produced approximately the same degree of reduction in the bone marrow blood flow seven months after the irradiation. However, the fall in the red blood cell volume was from 23 to 37% greater in the three fractions groups compared with that in the nine fractions groups. Using the red blood cell volume as a parameter the nominal standard dose formula underestimated the severity of radiation damage in rat bone marrow at seven months for irradiation with small numbers of large dose fractions. (orig.) [de

  14. Exchange interactions and Curie temperatures in Cr-based alloys in zinc blende structure: Volume- ans composition-dependence from first-principles calculations

    Czech Academy of Sciences Publication Activity Database

    Bose, S. K.; Kudrnovský, Josef

    2010-01-01

    Roč. 81, č. 5 (2010), 054446/1-054446/16 ISSN 1098-0121 R&D Projects: GA MŠk OC09028 Institutional research plan: CEZ:AV0Z10100520 Keywords : Cr-pnictides and chalcogenides * exchange interactions * Curie temperature, * first-principles Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 3.772, year: 2010

  15. Proceedings of waste stream minimization and utilization innovative concepts: An experimental technology exchange. Volume 2, Industrial liquid waste processing, industrial gaseous waste processing

    Energy Technology Data Exchange (ETDEWEB)

    Lee, V.E. [ed.; Watts, R.L.

    1993-04-01

    This two-volume proceedings summarize the results of fifteen innovations that were funded through the US Department of Energy`s Innovative Concept Program. The fifteen innovations were presented at the sixth Innovative Concepts Fair, held in Austin, Texas, on April 22--23, 1993. The concepts in this year`s fair address innovations that can substantially reduce or use waste streams. Each paper describes the need for the proposed concept, the concept being proposed, and the concept`s economics and market potential, key experimental results, and future development needs. The papers are divided into two volumes: Volume 1 addresses innovations for industrial solid waste processing and municipal waste reduction/recycling, and Volume 2 addresses industrial liquid waste processing and industrial gaseous waste processing. Individual reports are indexed separately.

  16. Proceedings of waste stream minimization and utilization innovative concepts: An experimental technology exchange. Volume 1, Industrial solid waste processing municipal waste reduction/recycling

    Energy Technology Data Exchange (ETDEWEB)

    Lee, V.E. [ed.; Watts, R.L.

    1993-04-01

    This two-volume proceedings summarizes the results of fifteen innovations that were funded through the US Department of Energy`s Innovative Concept Program. The fifteen innovations were presented at the sixth Innovative Concepts Fair, held in Austin, Texas, on April 22--23, 1993. The concepts in this year`s fair address innovations that can substantially reduce or use waste streams. Each paper describes the need for the proposed concept, the concept being proposed, and the concept`s economics and market potential, key experimental results, and future development needs. The papers are divided into two volumes: Volume 1 addresses innovations for industrial solid waste processing and municipal waste reduction/recycling, and Volume 2 addresses industrial liquid waste processing and industrial gaseous waste processing. Selected papers have been indexed separately for inclusion in the Energy Science and Technology Database.

  17. Higher convection volume exchange with online hemodiafiltration is associated with survival advantage for dialysis patients: the effect of adjustment for body size.

    Science.gov (United States)

    Davenport, Andrew; Peters, Sanne A E; Bots, Michiel L; Canaud, Bernard; Grooteman, Muriel P C; Asci, Gulay; Locatelli, Francesco; Maduell, Francisco; Morena, Marion; Nubé, Menso J; Ok, Ercan; Torres, Ferran; Woodward, Mark; Blankestijn, Peter J

    2016-01-01

    Mortality remains high for hemodialysis patients. Online hemodiafiltration (OL-HDF) removes more middle-sized uremic toxins but outcomes of individual trials comparing OL-HDF with hemodialysis have been discrepant. Secondary analyses reported higher convective volumes, easier to achieve in larger patients, and improved survival. Here we tested different methods to standardize OL-HDF convection volume on all-cause and cardiovascular mortality compared with hemodialysis. Pooled individual patient analysis of four prospective trials compared thirds of delivered convection volume with hemodialysis. Convection volumes were either not standardized or standardized to weight, body mass index, body surface area, and total body water. Data were analyzed by multivariable Cox proportional hazards modeling from 2793 patients. All-cause mortality was reduced when the convective dose was unstandardized or standardized to body surface area and total body water; hazard ratio (95% confidence intervals) of 0.65 (0.51-0.82), 0.74 (0.58-0.93), and 0.71 (0.56-0.93) for those receiving higher convective doses. Standardization by body weight or body mass index gave no significant survival advantage. Higher convection volumes were generally associated with greater survival benefit with OL-HDF, but results varied across different ways of standardization for body size. Thus, further studies should take body size into account when evaluating the impact of delivered convection volume on mortality end points. Copyright © 2015 International Society of Nephrology. Published by Elsevier Inc. All rights reserved.

  18. Exchange rate volatility and international trade: The option approach

    OpenAIRE

    Franke, Günter

    1986-01-01

    Usually it is argued that an increase in exchange rate volatility reduces the volume of international trade since trading firms are risk averse. This paper shows for risk neutral firms that the expected international trade volume in standardized commodities grows with exchange rate volatility. The firms adjust their trade volume to the exchange rate level. The more favorable the exchange rate is, the higher is the export volume. If the rate drops below some level, exports are stopped. Thus in...

  19. Optimization of Heat Exchangers

    International Nuclear Information System (INIS)

    Catton, Ivan

    2010-01-01

    The objective of this research is to develop tools to design and optimize heat exchangers (HE) and compact heat exchangers (CHE) for intermediate loop heat transport systems found in the very high temperature reator (VHTR) and other Generation IV designs by addressing heat transfer surface augmentation and conjugate modeling. To optimize heat exchanger, a fast running model must be created that will allow for multiple designs to be compared quickly. To model a heat exchanger, volume averaging theory, VAT, is used. VAT allows for the conservation of mass, momentum and energy to be solved for point by point in a 3 dimensional computer model of a heat exchanger. The end product of this project is a computer code that can predict an optimal configuration for a heat exchanger given only a few constraints (input fluids, size, cost, etc.). As VAT computer code can be used to model characteristics (pumping power, temperatures, and cost) of heat exchangers more quickly than traditional CFD or experiment, optimization of every geometric parameter simultaneously can be made. Using design of experiment, DOE and genetric algorithms, GE, to optimize the results of the computer code will improve heat exchanger design.

  20. Optimization of Heat Exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Ivan Catton

    2010-10-01

    The objective of this research is to develop tools to design and optimize heat exchangers (HE) and compact heat exchangers (CHE) for intermediate loop heat transport systems found in the very high temperature reator (VHTR) and other Generation IV designs by addressing heat transfer surface augmentation and conjugate modeling. To optimize heat exchanger, a fast running model must be created that will allow for multiple designs to be compared quickly. To model a heat exchanger, volume averaging theory, VAT, is used. VAT allows for the conservation of mass, momentum and energy to be solved for point by point in a 3 dimensional computer model of a heat exchanger. The end product of this project is a computer code that can predict an optimal configuration for a heat exchanger given only a few constraints (input fluids, size, cost, etc.). As VAT computer code can be used to model characteristics )pumping power, temperatures, and cost) of heat exchangers more quickly than traditional CFD or experiment, optimization of every geometric parameter simultaneously can be made. Using design of experiment, DOE and genetric algorithms, GE, to optimize the results of the computer code will improve heat exchanger disign.

  1. Low tidal volume ventilation use remains low in patients with acute respiratory distress syndrome at a single center.

    Science.gov (United States)

    Spece, Laura J; Mitchell, Kristina H; Caldwell, Ellen S; Gundel, Stephanie J; Jolley, Sarah E; Hough, Catherine L

    2018-04-01

    Low tidal volume ventilation (LTVV) reduces mortality in acute respiratory distress syndrome (ARDS) patients. Understanding local barriers to LTVV use at a former ARDS Network hospital may provide new insight to improve LTVV implementation. A cohort of 214 randomly selected adults met the Berlin definition of ARDS at Harborview Medical Center between 2008 and 2012. The primary outcome was the receipt of LTVV (tidal volume of ≤6.5mL/kg predicted body weight) within 48h of ARDS onset. We constructed a multivariable logistic regression model to identify factors associated with the outcome. Only 27% of patients received tidal volumes of ≤6.5mL/kg PBW within 48h of ARDS onset. Increasing plateau pressure (OR 1.11; 95% CI 1.03 to 1.19; p-value<0.01) was positively associated with LTVV use while increasing PaO 2 :F I O 2 ratio was negatively associated (OR 0.75; 95% CI 0.57 to 0.98; p-value 0.03). Physicians documented an ARDS diagnosis in only 21% of the cohort. Neither patient height nor gender was associated with LTVV use. Most ARDS patients did not receive LTVV despite implementation of a protocol. ARDS was also recognized in a minority of patients, suggesting an opportunity for improvement of care. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Single minimum incision endoscopic radical nephrectomy for renal tumors with preoperative virtual navigation using 3D-CT volume-rendering

    Directory of Open Access Journals (Sweden)

    Shioyama Yasukazu

    2010-04-01

    Full Text Available Abstract Background Single minimum incision endoscopic surgery (MIES involves the use of a flexible high-definition laparoscope to facilitate open surgery. We reviewed our method of radical nephrectomy for renal tumors, which is single MIES combined with preoperative virtual surgery employing three-dimensional CT images reconstructed by the volume rendering method (3D-CT images in order to safely and appropriately approach the renal hilar vessels. We also assessed the usefulness of 3D-CT images. Methods Radical nephrectomy was done by single MIES via the translumbar approach in 80 consecutive patients. We performed the initial 20 MIES nephrectomies without preoperative 3D-CT images and the subsequent 60 MIES nephrectomies with preoperative 3D-CT images for evaluation of the renal hilar vessels and the relation of each tumor to the surrounding structures. On the basis of the 3D information, preoperative virtual surgery was performed with a computer. Results Single MIES nephrectomy was successful in all patients. In the 60 patients who underwent 3D-CT, the number of renal arteries and veins corresponded exactly with the preoperative 3D-CT data (100% sensitivity and 100% specificity. These 60 nephrectomies were completed with a shorter operating time and smaller blood loss than the initial 20 nephrectomies. Conclusions Single MIES radical nephrectomy combined with 3D-CT and virtual surgery achieved a shorter operating time and less blood loss, possibly due to safer and easier handling of the renal hilar vessels.

  3. Measurement of Absolute Single and Double Charge Exchange Cross Sections for Si(7–10)+ at 0.88–2.50 KeV/u Impacting He and H2

    Science.gov (United States)

    Moradmand, A.; El Ghazaly, M. O. A.; Mahaptra, D. P.; Chutjian, A.

    2018-01-01

    First measurements are reported for total, absolute, single, and double charge-exchange (CE) cross sections for Si(7–10)+ ions in the solar wind (SW), colliding with the prevalent astrophysical species H2 and He found in comets, the interplanetary medium, and planetary atmospheres. Measurements are in the energy range 0.88–2.50 keV/u, corresponding to the energies of the “fast” and “slow” ion components of the SW. Limited agreement is found with single-exchange results calculated in the classical over-the-barrier model. These CE data are useful for understanding, in laboratory and astrophysical plasmas, photon emissions in the X-ray to visible energy range arising from resulting ion-stabilization steps.

  4. Evaluation of left ventricular function and volume in patients with dilated cardiomyopathy: Gated myocardial single-photon emission tomography (SPECT) versus echocardiography

    International Nuclear Information System (INIS)

    Berk, Fatma; Isgoren, S.; Demir, H.; Kozdag, G.; Ural, D.; Komsuoglu, B.

    2005-01-01

    Left ventricular function, volumes and regional wall motion provide valuable diagnostic information and are of long-term prognostic importance in patients with dilated cardiomyopathy (DCM). This study was designed to compare the effectiveness of 2D-echocardiography and gated single-photon emission tomography (SPECT) for evaluation of these parameters in patients with DCM. Gated SPECT and 2D-echocardiography were performed in 33 patients having DCM. Gated SPECT data, including left ventricular ejection fraction (LVEF), were processed using an automated algorithm. Standard technique was used for 2D-echocardiography. Regional wall motion was evaluated using both modalities and was scored by two independent observers using a 16-sement model with a 5-point scoring system. The overall agreement between the two imaging modalities for the assessment of regional wall motion was 56% (298/528 segments). With gated SPECT, LEVF, end-diastolic volume (EDV), and end-diastolic volume (EDV), and end-systolic volume (ESV) were 27+-9%, 217+-73mL, respectively, and 30.8%, 195+-58mL and, 137+-48 mL with echocardiography. The correlation between gated SPECT and 2-D-echocardiography was good (r=0.76, P<0.01) for the assessment of LVEF. The correlation for EDV and ESV were also good, but with wider limits of agreement (r=0.72, P<0.01 and r=0.73, P<0.01, respectively) and significantly higher values were obtained with gated SPECT (P<0.01). Gated SPECT and 2D-echocardiography correlate well for the assessment of LV function and LV volumes. Like 2D-echocardiography, gated SPECT provides reliable information about LV function and dimension with the additional advantage of perfusion data. (author)

  5. Reports distributed under the NRC Light-Water Reactor Safety Research Foreign Technical Exchange Program. Volume III, January--June 1977

    International Nuclear Information System (INIS)

    Sharp, D.S.; Cottrell, W.B.

    1977-01-01

    Lists of documents exchanged during the first half of 1977 under agreements between the U.S. Nuclear Regulatory Commission's Office of Nuclear Regulatory Research and the governments of France, Federal Republic of Germany, and Japan are presented. During this period, the NRC received 41 reports from France, 29 from F. R. Germany, and 24 from Japan, and in return sent 107 U.S. reports to each of these three countries

  6. Efeitos de diferentes volumes correntes e da pressão expiratória final positiva sobre a troca gasosa na fístula broncopleural experimental Effects of different tidal volumes and positive end expiratory pressure on gas exchange in experimental bronchopleural fistula

    Directory of Open Access Journals (Sweden)

    Maria Gabriela Cavicchia Toneloto

    2008-09-01

    melhora e o débito da fístula é reduzido quando comparado ao volume corrente de 10ml/Kg. Um baixo volume resulta em hipercapnia e grave dessaturação. Finalmente, em qualquer volume corrente, PEEP aumenta o débito da fístula e diminui a ventilação alveolar.OBJECTIVES: The present study was designed to identify the effect of positive end expiratory pressure (PEEP and the ideal pulmonary tidal volume to ventilate animals with a surgically produced bronchopleural fistula, aiming to reduce fistula output without affecting gas exchange. METHODS: Hemodynamic and respiratory assessment of gas exchange was obtained in five, healthy, young, mechanically ventilated Large White pigs under volume controlled ventilation with FiO2 of 0.4 and an inspiration:expiration ratio of 1:2, keeping respiratory rate at 22 cpm. A bronchopleural fistula was produced by resection of the lingula. Underwater seal drainage was installed and the thorax was hermetically closed. Gas exchange and fistula output were measured with the animals ventilated sequentially with tidal volumes of 4 ml/kg, 7 ml/kg and 10 ml/Kg alternating zero of positive end expiratory pressure (ZEEP and PEEP of 10 cmH2O, always in the same order. RESULTS: These findings are attributed to reduced alveolar ventilation and ventilation/perfusion abnormalities and were attenuated with larger tidal volumes. PEEP increases air leak, even with low volume (of 2.0 ± 2.8mL to 31 ± 20.7mL; p= 0.006 and decreases alveolar ventilation in all tidal volumes. Alveolar ventilation improved with larger tidal volumes, but increased fistula output (10 mL/kg - 25.8 ± 18.3mL to 80.2 ± 43.9mL; p=0.0010. Low tidal volumes result in hypercapnia (ZEEP - Toneloto MGC, Terzi RGG, Silva WA, Moraes AC, Moreira MM 83.7± 6.9 mmHg and with PEEP 10 - 93 ± 10.1mmHg and severely decreased arterial oxygen saturation, about of 84%. CONCLUSIONS: The tidal volume of 7 ml/Kg with ZEEP was considered the best tidal volume because, despite moderate hypercapnia

  7. Minimizing Back Exchange in the Hydrogen Exchange-Mass Spectrometry Experiment

    Science.gov (United States)

    Walters, Benjamin T.; Ricciuti, Alec; Mayne, Leland; Englander, S. Walter

    2012-12-01

    The addition of mass spectrometry (MS) analysis to the hydrogen exchange (HX) proteolytic fragmentation experiment extends powerful HX methodology to the study of large biologically important proteins. A persistent problem is the degradation of HX information due to back exchange of deuterium label during the fragmentation-separation process needed to prepare samples for MS measurement. This paper reports a systematic analysis of the factors that influence back exchange (solution pH, ionic strength, desolvation temperature, LC column interaction, flow rates, system volume). The many peptides exhibit a range of back exchange due to intrinsic amino acid HX rate differences. Accordingly, large back exchange leads to large variability in D-recovery from one residue to another as well as one peptide to another that cannot be corrected for by reference to any single peptide-level measurement. The usual effort to limit back exchange by limiting LC time provides little gain. Shortening the LC elution gradient by 3-fold only reduced back exchange by ~2 %, while sacrificing S/N and peptide count. An unexpected dependence of back exchange on ionic strength as well as pH suggests a strategy in which solution conditions are changed during sample preparation. Higher salt should be used in the first stage of sample preparation (proteolysis and trapping) and lower salt (<20 mM) and pH in the second stage before electrospray injection. Adjustment of these and other factors together with recent advances in peptide fragment detection yields hundreds of peptide fragments with D-label recovery of 90 % ± 5 %.

  8. Minimizing back exchange in the hydrogen exchange-mass spectrometry experiment.

    Science.gov (United States)

    Walters, Benjamin T; Ricciuti, Alec; Mayne, Leland; Englander, S Walter

    2012-12-01

    The addition of mass spectrometry (MS) analysis to the hydrogen exchange (HX) proteolytic fragmentation experiment extends powerful HX methodology to the study of large biologically important proteins. A persistent problem is the degradation of HX information due to back exchange of deuterium label during the fragmentation-separation process needed to prepare samples for MS measurement. This paper reports a systematic analysis of the factors that influence back exchange (solution pH, ionic strength, desolvation temperature, LC column interaction, flow rates, system volume). The many peptides exhibit a range of back exchange due to intrinsic amino acid HX rate differences. Accordingly, large back exchange leads to large variability in D-recovery from one residue to another as well as one peptide to another that cannot be corrected for by reference to any single peptide-level measurement. The usual effort to limit back exchange by limiting LC time provides little gain. Shortening the LC elution gradient by 3-fold only reduced back exchange by ~2%, while sacrificing S/N and peptide count. An unexpected dependence of back exchange on ionic strength as well as pH suggests a strategy in which solution conditions are changed during sample preparation. Higher salt should be used in the first stage of sample preparation (proteolysis and trapping) and lower salt (<20 mM) and pH in the second stage before electrospray injection. Adjustment of these and other factors together with recent advances in peptide fragment detection yields hundreds of peptide fragments with D-label recovery of 90% ± 5%.

  9. Impact of injection speed and volume on perceived pain during subcutaneous injections into the abdomen and thigh: a single-centre, randomized controlled trial.

    Science.gov (United States)

    Heise, T; Nosek, L; Dellweg, S; Zijlstra, E; Præstmark, K A; Kildegaard, J; Nielsen, G; Sparre, T

    2014-10-01

    The aim of this study was to assess pain associated with subcutaneous injection into the abdomen and thigh of different combinations of injection speeds and volumes. The study was a single-centre, one-visit, double-blinded, randomized controlled trial in 82 adults with type 1 or type 2 diabetes receiving daily injections of insulin or glucagon-like peptide-1 (GLP-1) agonists. Participants received 17 subcutaneous injections (12 in abdomen, 5 in thigh) of saline at different injection speeds (150, 300 and 450 µl/s), with different volumes (400, 800, 1200 and 1600 µl), and two needle insertions without any injection. Pain was evaluated on a 100-mm visual analogue scale (VAS) (0 mm no pain, 100 mm worst pain) and on a yes/no scale for pain acceptability. Injection speed had no impact on injection pain (p = 0.833). Injection of larger volumes caused significantly more pain [VAS least square mean differences 1600 vs. 400 µl, 7 · 2 mm (95% confidence interval - CI; 4.6-9.7; p technique to reduce their injection pain. Furthermore, these findings may have important implications for the development of new injection devices and drug formulations for clinical practice. © 2014 John Wiley & Sons Ltd.

  10. Expanding Lorentz and spectrum corrections to large volumes of reciprocal space for single-crystal time-of-flight neutron diffraction.

    Science.gov (United States)

    Michels-Clark, Tara M; Savici, Andrei T; Lynch, Vickie E; Wang, Xiaoping; Hoffmann, Christina M

    2016-04-01

    Evidence is mounting that potentially exploitable properties of technologically and chemically interesting crystalline materials are often attributable to local structure effects, which can be observed as modulated diffuse scattering (mDS) next to Bragg diffraction (BD). BD forms a regular sparse grid of intense discrete points in reciprocal space. Traditionally, the intensity of each Bragg peak is extracted by integration of each individual reflection first, followed by application of the required corrections. In contrast, mDS is weak and covers expansive volumes of reciprocal space close to, or between, Bragg reflections. For a representative measurement of the diffuse scattering, multiple sample orientations are generally required, where many points in reciprocal space are measured multiple times and the resulting data are combined. The common post-integration data reduction method is not optimal with regard to counting statistics. A general and inclusive data processing method is needed. In this contribution, a comprehensive data analysis approach is introduced to correct and merge the full volume of scattering data in a single step, while correctly accounting for the statistical weight of the individual measurements. Development of this new approach required the exploration of a data treatment and correction protocol that includes the entire collected reciprocal space volume, using neutron time-of-flight or wavelength-resolved data collected at TOPAZ at the Spallation Neutron Source at Oak Ridge National Laboratory.

  11. Columbia University flow instability experimental program: Volume 2. Single tube uniformly heated tests -- Part 2: Uncertainty analysis and data

    International Nuclear Information System (INIS)

    Dougherty, T.; Maciuca, C.; McAssey, E.V. Jr.; Reddy, D.G.; Yang, B.W.

    1990-05-01

    In June 1988, Savannah River Laboratory requested that the Heat Transfer Research Facility modify the flow excursion program, which had been in progress since November 1987, to include testing of single tubes in vertical down-flow over a range of length to diameter (L/D) ratios of 100 to 500. The impetus for the request was the desire to obtain experimental data as quickly as possible for code development work. In July 1988, HTRF submitted a proposal to SRL indicating that by modifying a facility already under construction the data could be obtained within three to four months. In January 1990, HTFR issued report CU-HTRF-T4, part 1. This report contained the technical discussion of the results from the single tube uniformly heated tests. The present report is part 2 of CU-HTRF-T4 which contains further discussion of the uncertainty analysis and the complete set of data

  12. Reports distributed under the NRC Light-Water Reactor Safety Research Foreign Technical Exchange Program. Volume IV, July--December 1977

    International Nuclear Information System (INIS)

    Sharp, D.S.; Cottrell, W.B.

    1978-01-01

    Lists of documents exchanged during the second half of 1977 under agreements between the U.S. Nuclear Regulatory Commission's Office of Nuclear Regulatory Research and the governments of France, Federal Republic of Germany, Japan, and the United Kingdom are presented. During this period, the NRC received 1 report from France, 40 from the Federal Republic of Germany, and 11 from Japan, and in return sent 112 U.S. reports to each of these three countries and 23 reports to the United Kingdom

  13. Heat exchanger

    International Nuclear Information System (INIS)

    Dostatni, A.W.; Dostatni, Michel.

    1976-01-01

    In the main patent, a description was given of a heat exchanger with an exchange surface in preformed sheet metal designed for the high pressure and temperature service particularly encountered in nuclear pressurized water reactors and which is characterised by the fact that it is composed of at least one exchanger bundle sealed in a containment, the said bundle or bundles being composed of numerous juxtaposed individual compartments whose exchange faces are built of preformed sheet metal. The present addendun certificate concerns shapes of bundles and their positioning methods in the exchanger containment enabling its compactness to be increased [fr

  14. Effect of speed endurance training and reduced training volume on running economy and single muscle fiber adaptations in trained runners

    DEFF Research Database (Denmark)

    Skovgaard, Casper; Christiansen, Danny; Christensen, Peter Møller

    2018-01-01

    The aim of the present study was to examine whether improved running economy with a period of speed endurance training and reduced training volume could be related to adaptations in specific muscle fibers. Twenty trained male (n = 14) and female (n = 6) runners (maximum oxygen consumption (VO2 -max...... was performed. In addition, running at 60% vVO2 -max, and a 10-km run was performed in a normal and a muscle slow twitch (ST) glycogen-depleted condition. After compared to before the intervention, expression of mitochondrial uncoupling protein 3 (UCP3) was lower (P ....05) in ST muscle fibers, and sarcoplasmic reticulum calcium ATPase 1 (SERCA1) was lower (P VO2 -max (11.6 ± 0.2 km/h) and at v10-km (13.7 ± 0.3 km/h) was ~2% better (P

  15. Evaluation of left ventricular function and volumes in patients with ischaemic cardiomyopathy: gated single-photon emission computed tomography versus two-dimensional echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Vourvouri, E.C.; Poldermans, D.; Sianos, G.; Sozzi, F.B.; Schinkel, A.F.L.; Sutter, J. de; Roelandt, J.R.T.C. [Dept. of Cardiology, Erasmus Medical Center Rotterdam (Netherlands); Bax, J.J. [Dept. of Cardiology, Leiden Univ. Medical Center (Netherlands); Parcharidis, G. [Dept. of Cardiology, AHEPA Univ. Hospital, Thessaloniki (Greece); Valkema, R. [Dept. of Nuclear Medicine, Erasmus Medical Center Rotterdam (Netherlands)

    2001-11-01

    The objective of this study was to perform a head-to-head comparison between two-dimensional (2D) echocardiography and gated single-photon emission computed tomography (SPET) for the evaluation of left ventricular (LV) function and volumes in patients with severe ischaemic LV dysfunction. Thirty-two patients with chronic ischaemic LV dysfunction [mean LV ejection fraction (EF) 25%{+-}6%] were studied with gated SPET and 2D echocardiography. Regional wall motion was evaluated by both modalities and scored by two independent observers using a 16-segment model with a 5-point scoring system (1= normokinesia, 2= mild hypokinesia, 3= severe hypokinesia, 4= akinesia and 5= dyskinesia). LVEF and LV end-diastolic and end-systolic volumes were evaluated by 2D echocardiography using the Simpson's biplane discs method. The same parameters were calculated using quantitative gated SPET software (QGS, Cedars-Sinai Medical Center). The overall agreement between the two imaging modalities for assessment of regional wall motion was 69%. The correlations between gated SPET and 2D echocardiography for the assessment of end-diastolic and end-systolic volumes were excellent (r=0.94, P<0.01, and r=0.96, P<0.01, respectively). The correlation for LVEF was also good (r=0.83, P<0.01). In conclusion: in patients with ischaemic cardiomyopathy, close and significant relations between gated SPET and 2D echocardiography were observed for the assessment of regional and global LV function and LV volumes; gated SPET has the advantage that it provides information on both LV function/dimensions and perfusion. (orig.)

  16. Effect of speed endurance training and reduced training volume on running economy and single muscle fiber adaptations in trained runners.

    Science.gov (United States)

    Skovgaard, Casper; Christiansen, Danny; Christensen, Peter M; Almquist, Nicki W; Thomassen, Martin; Bangsbo, Jens

    2018-02-01

    The aim of the present study was to examine whether improved running economy with a period of speed endurance training and reduced training volume could be related to adaptations in specific muscle fibers. Twenty trained male (n = 14) and female (n = 6) runners (maximum oxygen consumption (VO 2 -max): 56.4 ± 4.6 mL/min/kg) completed a 40-day intervention with 10 sessions of speed endurance training (5-10 × 30-sec maximal running) and a reduced (36%) volume of training. Before and after the intervention, a muscle biopsy was obtained at rest, and an incremental running test to exhaustion was performed. In addition, running at 60% vVO 2 -max, and a 10-km run was performed in a normal and a muscle slow twitch (ST) glycogen-depleted condition. After compared to before the intervention, expression of mitochondrial uncoupling protein 3 (UCP3) was lower (P < 0.05) and dystrophin was higher (P < 0.05) in ST muscle fibers, and sarcoplasmic reticulum calcium ATPase 1 (SERCA1) was lower (P < 0.05) in fast twitch muscle fibers. Running economy at 60% vVO 2 -max (11.6 ± 0.2 km/h) and at v10-km (13.7 ± 0.3 km/h) was ~2% better (P < 0.05) after the intervention in the normal condition, but unchanged in the ST glycogen-depleted condition. Ten kilometer performance was improved (P < 0.01) by 3.2% (43.7 ± 1.0 vs. 45.2 ± 1.2 min) and 3.9% (45.8 ± 1.2 vs. 47.7 ± 1.3 min) in the normal and the ST glycogen-depleted condition, respectively. VO 2 -max was the same, but vVO 2 -max was 2.0% higher (P < 0.05; 19.3 ± 0.3 vs. 18.9 ± 0.3 km/h) after than before the intervention. Thus, improved running economy with intense training may be related to changes in expression of proteins linked to energy consuming processes in primarily ST muscle fibers. © 2018 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  17. The Role of Anisotropic Exchange in Single Molecule Magnets: A CASSCF/NEVPT2 Study of the Fe4 SMM Building Block [Fe2(OCH32(dbm4] Dimer

    Directory of Open Access Journals (Sweden)

    Alessandro Lunghi

    2016-09-01

    Full Text Available The rationalisation of single molecule magnets’ (SMMs magnetic properties by quantum mechanical approaches represents a major task in the field of the Molecular Magnetism. The fundamental interpretative key of molecular magnetism is the phenomenological Spin Hamiltonian and the understanding of the role of its different terms by electronic structure calculations is expected to steer the rational design of new and more performing SMMs. This paper deals with the ab initio calculation of isotropic and anisotropic exchange contributions in the Fe(III dimer [Fe 2 (OCH 3 2 (dbm 4 ]. This system represents the building block of one of the most studied Single Molecule Magnets ([Fe 4 RC(CH 2 O 3 2 (dpm 6 ] where R can be an aliphatic chain or a phenyl group just to name the most common functionalization groups and its relatively reduced size allows the use of a high computational level of theory. Calculations were performed using CASSCF and NEVPT2 approaches on the X-ray geometry as assessment of the computational protocol, which has then be used to evinced the importance of the outer coordination shell nature through organic ligand modelization. Magneto-structural correlations as function of internal degrees of freedom for isotropic and anisotropic exchange contributions are also presented, outlining, for the first time, the extremely rapidly changing nature of the anisotropic exchange coupling.

  18. Small Column Ion Exchange

    International Nuclear Information System (INIS)

    Huff, Thomas

    2010-01-01

    Small Column Ion Exchange (SCIX) leverages a suite of technologies developed by DOE across the complex to achieve lifecycle savings. Technologies are applicable to multiple sites. Early testing supported multiple sites. Balance of SRS SCIX testing supports SRS deployment. A forma Systems Engineering Evaluation (SEE) was performed and selected Small Column Ion Exchange columns containing Crystalline Silicotitanate (CST) in a 2-column lead/lag configuration. SEE considered use of Spherical Resorcinol-Formaldehyde (sRF). Advantages of approach at SRS include: (1) no new buildings, (2) low volume of Cs waste in solid form compared to aqueous strip effluent; and availability of downstream processing facilities for immediate processing of spent resin.

  19. Effects of short-term pressure-controlled ventilation on gas exchange, airway pressures, and gas distribution in patients with acute lung injury/ARDS: comparison with volume-controlled ventilation.

    Science.gov (United States)

    Prella, Maura; Feihl, François; Domenighetti, Guido

    2002-10-01

    The potential clinical benefits of pressure-controlled ventilation (PCV) over volume-controlled ventilation (VCV) in patients with acute lung injury (ALI) or ARDS still remain debated. We compared PCV with VCV in patients with ALI/ARDS with respect to the following physiologic end points: (1) gas exchange and airway pressures, and (2) CT scan intrapulmonary gas distribution at end-expiration. Prospective, observational study. A multidisciplinary ICU in a nonuniversity, acute-care hospital. Ten patients with ALI or ARDS (9 men and 1 woman; age range, 17 to 80 years). Sequential ventilation in PCV and VCV with a constant inspiratory/expiratory ratio, tidal volume, respiratory rate, and total positive end-expiratory pressure; measurement of gas exchange and airway pressures; and achievement of CT sections at lung base, hilum, and apex for the quantitative analysis of lung densities and of aerated vs nonaerated zones. PaO(2), PaCO(2), and PaO(2)/fraction of inspired oxygen ratio levels did not differ between PCV and VCV. Peak airway pressure (Ppeak) was significantly lower in PCV compared with VCV (26 +/- 2 cm H(2)O vs 31 +/- 2 cm H(2)O; p mean +/- SEM). The surface areas of the nonaerated zones as well as the total areas at each section level were unchanged in PCV compared with VCV, except at the apex level, where there was a significantly greater nonaerated area in VCV (11 +/- 2 cm(2) vs 9 +/- 2 cm(2); p mean CT number of each lung (20 lungs from 10 patients) was similar in the two modes, as were the density values at the basal and apical levels; the hilum mean CT number was - 442 +/- 28 Hounsfield units (HU) in VCV and - 430 +/- 26 HU in PCV (p lower Ppeaks through the precise titration of the lung distending pressure, and might be applied to avoid regional overdistension by means of a more homogeneous gas distribution.

  20. Preliminary SP-100/Stirling heat exchanger designs

    International Nuclear Information System (INIS)

    Schmitz, P.; Tower, L.; Blue, B.; Dunn, P.

    1994-01-01

    Analytic modeling of several heat exchanger concepts to couple the SP-100 nuclear reactor lithium loop and the Space Stirling Power Convertor (SSPC) was performed. Four 25 kWe SSPC's are used to produce the required 100 kW of electrical power. This design work focused on the interface between a single SSPC and the primary lithium loop. Manifolding to separate and collect the four channel flow was not modeled. This work modeled two separate types of heat exchanger interfaces (conductive coupling and radiative coupling) to explore their relative advantages and disadvantages. The minimum mass design of the conductively coupled concepts was 18 kg or 0.73 kg/kWe for a single 25 kWe convertor. The minimum mass radiatively coupled concept was 41 kg or 1.64 kg/kWe. The direct conduction heat exchanger provides a lighter weight system because of its ability to operate the Stirling convertor evaporator at higher heat fluxes than those attainable by the radiatively coupled systems. Additionally the conductively coupled concepts had relatively small volumes and provide potentially simpler assembly. Their disadvantages were the tight tolerances and material joining problems associated with this refractory to superalloy interface. The advantages of the radiatively coupled designs were the minimal material interface problems

  1. Preliminary SP-100/Stirling heat exchanger designs

    International Nuclear Information System (INIS)

    Schmitz, P.; Tower, L.; Dawson, R.; Blue, B.; Dunn, P.

    1993-12-01

    Analytic modeling of several heat exchanger concepts to couple the SP-100 nuclear reactor primary lithium loop and the Space Stirling Power Convertor (SSPC) was performed. Four 25 kWe SSPC's are used to produce the required 100 kW of electrical power. This design work focused on the interface between a single SSPC and the primary lithium loop. Manifolding to separate and collect the four channel flow was not modeled. This work modeled two separate types of heat exchanger interfaces (conductive coupling and radiative coupling) to explore their relative advantages and disadvantages. The minimum mass design of the conductively coupled concepts was 18 kg or 0.73 kg/kWe for a single 25 kWe convertor. The minimum mass radiatively coupled concept was 41 kg or 1.64 kg/kWe. The direct conduction heat exchanger provides a lighter weight system because of its ability to operate the Stirling convertor evaporator at higher heat fluxes than those attainable by the radiatively coupled systems. Additionally the conductively coupled concepts had relatively small volumes and provide potentially simpler assembly. Their disadvantages were the tight tolerances and material joining problems associated with this refractory to superalloy interface. The advantages of the radiatively coupled designs were the minimal material interface problems

  2. Fluorescent dye imaging of the volume sampled by single well forced-gradient tracer tests evaluated in a laboratory-scale aquifer physical model.

    Science.gov (United States)

    Barns, Gareth L; Wilson, Ryan D; Thornton, Steven F

    2012-02-01

    This study presents a new method to visualise forced-gradient tracer tests in 2-D using a laboratory-scale aquifer physical model. Experiments were designed to investigate the volume of aquifer sampled in vertical dipole flow tracer tests (DFTT) and push-pull tests (PPT), using a miniature monitoring well and straddle packer arrangement equipped with solute injection and recovery chambers. These tests have previously been used to estimate bulk aquifer hydraulic and transport properties for the evaluation of natural attenuation and other remediation approaches. Experiments were performed in a silica glass bead-filled box, using a fluorescent tracer (fluorescein) to deduce conservative solute transport paths. Digital images of fluorescein transport were captured under ultraviolet light and processed to analyse tracer plume geometry and obtain point-concentration breakthrough histories. Inorganic anion mixtures were also used to obtain conventional tracer breakthrough histories. Concentration data from the conservative tracer breakthrough curves was compared with the digital images and a well characterised numerical model. The results show that the peak tracer breakthrough response in dipole flow tracer tests samples a zone of aquifer close to the well screen, while the sampling volume of push-pull tests is limited by the length of the straddle packers used. The effective sampling volume of these single well forced-gradient tests in isotropic conditions can be estimated with simple equations. The experimental approach offers the opportunity to evaluate under controlled conditions the theoretical basis, design and performance of DFTTs and PPTs in porous media in relation to measured flow and transport properties. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Resistance Training with Single vs. Multi-joint Exercises at Equal Total Load Volume: Effects on Body Composition, Cardiorespiratory Fitness, and Muscle Strength

    Science.gov (United States)

    Paoli, Antonio; Gentil, Paulo; Moro, Tatiana; Marcolin, Giuseppe; Bianco, Antonino

    2017-01-01

    The present study aimed to compare the effects of equal-volume resistance training performed with single-joint (SJ) or multi-joint exercises (MJ) on VO2max, muscle strength and body composition in physically active males. Thirty-six participants were divided in two groups: SJ group (n = 18, 182.1 ± 5.2, 80.03 ± 2.78 kg, 23.5 ± 2.7 years) exercised with only SJ exercises (e.g., dumbbell fly, knee extension, etc.) and MJ group (n = 18, 185.3 ± 3.6 cm, 80.69 ± 2.98 kg, 25.5 ± 3.8 years) with only MJ exercises (e.g., bench press, squat, etc.). The total work volume (repetitions × sets × load) was equated between groups. Training was performed three times a week for 8 weeks. Before and after the training period, participants were tested for VO2max, body composition, 1 RM on the bench press, knee extension and squat. Analysis of covariance (ANCOVA) was used to compare post training values between groups, using baseline values as covariates. According to the results, both groups decreased body fat and increased fat free mass with no difference between them. Whilst both groups significantly increased cardiorespiratory fitness and maximal strength, the improvements in MJ group were higher than for SJ in VO2max (5.1 and 12.5% for SJ and MJ), bench press 1 RM (8.1 and 10.9% for SJ and MJ), knee extension 1 RM (12.4 and 18.9% for SJ and MJ) and squat 1 RM (8.3 and 13.8% for SJ and MJ). In conclusion, when total work volume was equated, RT programs involving MJ exercises appear to be more efficient for improving muscle strength and maximal oxygen consumption than programs involving SJ exercises, but no differences were found for body composition. PMID:29312007

  4. Fluorescent dye imaging of the volume sampled by single well forced-gradient tracer tests evaluated in a laboratory-scale aquifer physical model

    Science.gov (United States)

    Barns, Gareth L.; Wilson, Ryan D.; Thornton, Steven F.

    2012-02-01

    This study presents a new method to visualise forced-gradient tracer tests in 2-D using a laboratory-scale aquifer physical model. Experiments were designed to investigate the volume of aquifer sampled in vertical dipole flow tracer tests (DFTT) and push-pull tests (PPT), using a miniature monitoring well and straddle packer arrangement equipped with solute injection and recovery chambers. These tests have previously been used to estimate bulk aquifer hydraulic and transport properties for the evaluation of natural attenuation and other remediation approaches. Experiments were performed in a silica glass bead-filled box, using a fluorescent tracer (fluorescein) to deduce conservative solute transport paths. Digital images of fluorescein transport were captured under ultraviolet light and processed to analyse tracer plume geometry and obtain point-concentration breakthrough histories. Inorganic anion mixtures were also used to obtain conventional tracer breakthrough histories. Concentration data from the conservative tracer breakthrough curves was compared with the digital images and a well characterised numerical model. The results show that the peak tracer breakthrough response in dipole flow tracer tests samples a zone of aquifer close to the well screen, while the sampling volume of push-pull tests is limited by the length of the straddle packers used. The effective sampling volume of these single well forced-gradient tests in isotropic conditions can be estimated with simple equations. The experimental approach offers the opportunity to evaluate under controlled conditions the theoretical basis, design and performance of DFTTs and PPTs in porous media in relation to measured flow and transport properties. DFTT = Dipole Flow Tracer Test, PPT = Push Pull Tracer Test.

  5. Electron paramagnetic resonance study of exchange coupled Ce.sup.3+./sup. ions in Lu.sub.2./sub.SiO.sub.5./sub. single crystal scintillator

    Czech Academy of Sciences Publication Activity Database

    Buryi, Maksym; Laguta, Valentyn; Rosa, Jan; Nikl, Martin

    2016-01-01

    Roč. 90, Jul (2016), s. 23-26 ISSN 1350-4487 R&D Projects: GA ČR GAP204/12/0805; GA MŠk(CZ) LM2011029; GA MŠk LO1409 Institutional support: RVO:68378271 Keywords : electron paramagnetic resonance * scintillators * lutetium oxyorthosilicate * exchange coupled ions * cerium ions Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.442, year: 2016

  6. Electron exchange by hexakis(tert-butyl-isocyanide)- and hexakis(cyclohexyl isocyanide)manganese(I,II). Solvent effect on the rate constant and the volume of activation

    International Nuclear Information System (INIS)

    Stebler, M.; Nielson, R.M.; Siems, W.F.; Hunt, J.P.; Dodgen, H.W.; Wherland, H.W.

    1988-01-01

    The rate of electron self-exchange of Mn(CNC(CH 3 ) 3 ) 6 +/2+ and Mn(CNC 6 H 11 ) 6 +/2+ as the BF 4 - salts has been measured by 55 Mn NMR line broadening as a function of pressure, temperature, and concentration in acetonitrile, bromobenzene, benzonitrile, acetone, diethyl ketone, methanol, ethanol, methylene chloride, and trimethyl phosphate, and various binary mixtures of methylene chloride, bromobenzene, and acetonitrile. The values of ΔV double dagger obtained are negative and cover a range of ca. 12 cm 3 /mol, which is limited by ion pairing in the solvents of lower dielectric constant. The variation of the ambient pressure rate constant with solvent is qualitatively different for Mn(CNC(CH 3 ) 3 ) 6 +/2+ reaction than was observed for the Mn(CNC 6 H 11 ) 6 +/2+ reaction. This is taken as further evidence for a significant influence of rather subtle differences in solvation on the molecular level that are not approximated by dielectric continuum models. 30 references, 3 tables

  7. Development of a coal-fueled Internal Manifold Heat Exchanger (IMHEX{reg_sign}) molten carbonate fuel cell. Volumes 1--6, Final report

    Energy Technology Data Exchange (ETDEWEB)

    1991-09-01

    The design of a CGMCFC electric generation plant that will provide a cost of eletricity (COE) which is lower than that of current electric generation technologies and which is competitive with other long-range electric generating systems is presented. This effort is based upon the Internal Manifold Heat Exchanger (IMHEX) technology as developed by the Institute of Gas Technology (IGT). The project was executed by selecting economic and performance objectives for alternative plant arrangements while considering process constraints identified during IMHEX fuel cell development activities at ICT. The four major subsystems of a coal-based MCFC power plant are coal gasification, gas purification, fuel cell power generation and the bottoming cycle. The design and method of operation of each subsystem can be varied, and, depending upon design choices, can have major impact on both the design of other subsystems and the resulting cost of electricity. The challenge of this project was to select, from a range of design parameters, those operating conditions that result in a preferred plant design. Computer modelling was thus used to perform sensitivity analyses of as many system variables as program resources and schedules would permit. In any systems analysis, it is imperative that the evaluation methodology be verifiable and comparable. The TAG Class I develops comparable (if imprecise) data on performance and costs for the alternative cases being studied. It identifies, from a range of options, those which merit more exacting scrutiny to be undertaken at the second level, TAG class II analysis.

  8. Finite volume scheme for double convection-diffusion exchange of solutes in bicarbonate high-flux hollow-fiber dialyzer therapy.

    Science.gov (United States)

    Annan, Kodwo

    2012-01-01

    The efficiency of a high-flux dialyzer in terms of buffering and toxic solute removal largely depends on the ability to use convection-diffusion mechanism inside the membrane. A two-dimensional transient convection-diffusion model coupled with acid-base correction term was developed. A finite volume technique was used to discretize the model and to numerically simulate it using MATLAB software tool. We observed that small solute concentration gradients peaked and were large enough to activate solute diffusion process in the membrane. While CO(2) concentration gradients diminished from their maxima and shifted toward the end of the membrane, HCO(3)(-) concentration gradients peaked at the same position. Also, CO(2) concentration decreased rapidly within the first 47 minutes while optimal HCO(3)(-) concentration was achieved within 30 minutes of the therapy. Abnormally high diffusion fluxes were observed near the blood-membrane interface that increased diffusion driving force and enhanced the overall diffusive process. While convective flux dominated total flux during the dialysis session, there was a continuous interference between convection and diffusion fluxes that call for the need to seek minimal interference between these two mechanisms. This is critical for the effective design and operation of high-flux dialyzers.

  9. Finite Volume Scheme for Double Convection-Diffusion Exchange of Solutes in Bicarbonate High-Flux Hollow-Fiber Dialyzer Therapy

    Directory of Open Access Journals (Sweden)

    Kodwo Annan

    2012-01-01

    Full Text Available The efficiency of a high-flux dialyzer in terms of buffering and toxic solute removal largely depends on the ability to use convection-diffusion mechanism inside the membrane. A two-dimensional transient convection-diffusion model coupled with acid-base correction term was developed. A finite volume technique was used to discretize the model and to numerically simulate it using MATLAB software tool. We observed that small solute concentration gradients peaked and were large enough to activate solute diffusion process in the membrane. While CO2 concentration gradients diminished from their maxima and shifted toward the end of the membrane, concentration gradients peaked at the same position. Also, CO2 concentration decreased rapidly within the first 47 minutes while optimal concentration was achieved within 30 minutes of the therapy. Abnormally high diffusion fluxes were observed near the blood-membrane interface that increased diffusion driving force and enhanced the overall diffusive process. While convective flux dominated total flux during the dialysis session, there was a continuous interference between convection and diffusion fluxes that call for the need to seek minimal interference between these two mechanisms. This is critical for the effective design and operation of high-flux dialyzers.

  10. Heat exchanger

    International Nuclear Information System (INIS)

    Leigh, D.G.

    1976-01-01

    The arrangement described relates particularly to heat exchangers for use in fast reactor power plants, in which heat is extracted from the reactor core by primary liquid metal coolant and is then transferred to secondary liquid metal coolant by means of intermediate heat exchangers. One of the main requirements of such a system, if used in a pool type fast reactor, is that the pressure drop on the primary coolant side must be kept to a minimum consistent with the maintenance of a limited dynamic head in the pool vessel. The intermediate heat exchanger must also be compact enough to be accommodated in the reactor vessel, and the heat exchanger tubes must be available for inspection and the detection and plugging of leaks. If, however, the heat exchanger is located outside the reactor vessel, as in the case of a loop system reactor, a higher pressure drop on the primary coolant side is acceptable, and space restriction is less severe. An object of the arrangement described is to provide a method of heat exchange and a heat exchanger to meet these problems. A further object is to provide a method that ensures that excessive temperature variations are not imposed on welded tube joints by sudden changes in the primary coolant flow path. Full constructional details are given. (U.K.)

  11. Removal of transmissible spongiform encephalopathy prion from large volumes of cell culture media supplemented with fetal bovine serum by using hollow fiber anion-exchange membrane chromatography.

    Science.gov (United States)

    Chou, Ming Li; Bailey, Andy; Avory, Tiffany; Tanimoto, Junji; Burnouf, Thierry

    2015-01-01

    Cases of variant Creutzfeldt-Jakob disease in people who had consumed contaminated meat products from cattle with bovine spongiform encephalopathy emphasize the need for measures aimed at preventing the transmission of the pathogenic prion protein (PrPSc) from materials derived from cattle. Highly stringent scrutiny is required for fetal bovine serum (FBS), a growth-medium supplement used in the production of parenteral vaccines and therapeutic recombinant proteins and in the ex vivo expansion of stem cells for transplantation. One such approach is the implementation of manufacturing steps dedicated to removing PrPSc from materials containing FBS. We evaluated the use of the QyuSpeed D (QSD) adsorbent hollow-fiber anion-exchange chromatographic column (Asahi Kasei Medical, Tokyo, Japan) for the removal of PrPSc from cell culture media supplemented with FBS. We first established that QSD filtration had no adverse effect on the chemical composition of various types of culture media supplemented with 10% FBS or the growth and viability characteristics of human embryonic kidney (HEK293) cells, baby hamster kidney (BHK-21) cells, African green monkey kidney (Vero) cells, and Chinese hamster ovary (CHO-k1) cells propagated in the various culture-medium filtrates. We used a 0.6-mL QSD column for removing PrPSc from up to 1000 mL of Dulbecco's modified Eagle's medium containing 10% FBS previously spiked with the 263K strain of hamster-adapted scrapie. The Western blot analysis, validated alongside an infectivity assay, revealed that the level of PrPSc in the initial 200mL flow-through was reduced by 2.5 to > 3 log10, compared with that of the starting material. These results indicate that QSD filtration removes PrPSc from cell culture media containing 10% FBS, and demonstrate the ease with which QSD filtration can be implemented in at industrial-scale to improve the safety of vaccines, therapeutic recombinant proteins, and ex vivo expanded stem cells produced using growth

  12. Removal of transmissible spongiform encephalopathy prion from large volumes of cell culture media supplemented with fetal bovine serum by using hollow fiber anion-exchange membrane chromatography.

    Directory of Open Access Journals (Sweden)

    Ming Li Chou

    Full Text Available Cases of variant Creutzfeldt-Jakob disease in people who had consumed contaminated meat products from cattle with bovine spongiform encephalopathy emphasize the need for measures aimed at preventing the transmission of the pathogenic prion protein (PrPSc from materials derived from cattle. Highly stringent scrutiny is required for fetal bovine serum (FBS, a growth-medium supplement used in the production of parenteral vaccines and therapeutic recombinant proteins and in the ex vivo expansion of stem cells for transplantation. One such approach is the implementation of manufacturing steps dedicated to removing PrPSc from materials containing FBS. We evaluated the use of the QyuSpeed D (QSD adsorbent hollow-fiber anion-exchange chromatographic column (Asahi Kasei Medical, Tokyo, Japan for the removal of PrPSc from cell culture media supplemented with FBS. We first established that QSD filtration had no adverse effect on the chemical composition of various types of culture media supplemented with 10% FBS or the growth and viability characteristics of human embryonic kidney (HEK293 cells, baby hamster kidney (BHK-21 cells, African green monkey kidney (Vero cells, and Chinese hamster ovary (CHO-k1 cells propagated in the various culture-medium filtrates. We used a 0.6-mL QSD column for removing PrPSc from up to 1000 mL of Dulbecco's modified Eagle's medium containing 10% FBS previously spiked with the 263K strain of hamster-adapted scrapie. The Western blot analysis, validated alongside an infectivity assay, revealed that the level of PrPSc in the initial 200mL flow-through was reduced by 2.5 to > 3 log10, compared with that of the starting material. These results indicate that QSD filtration removes PrPSc from cell culture media containing 10% FBS, and demonstrate the ease with which QSD filtration can be implemented in at industrial-scale to improve the safety of vaccines, therapeutic recombinant proteins, and ex vivo expanded stem cells produced

  13. HEAT EXCHANGER

    Science.gov (United States)

    Fox, T.H. III; Richey, T. Jr.; Winders, G.R.

    1962-10-23

    A heat exchanger is designed for use in the transfer of heat between a radioactive fiuid and a non-radioactive fiuid. The exchanger employs a removable section containing the non-hazardous fluid extending into the section designed to contain the radioactive fluid. The removable section is provided with a construction to cancel out thermal stresses. The stationary section is pressurized to prevent leakage of the radioactive fiuid and to maintain a safe, desirable level for this fiuid. (AEC)

  14. Resistance Training with Single vs. Multi-joint Exercises at Equal Total Load Volume: Effects on Body Composition, Cardiorespiratory Fitness, and Muscle Strength

    Directory of Open Access Journals (Sweden)

    Antonio Paoli

    2017-12-01

    Full Text Available The present study aimed to compare the effects of equal-volume resistance training performed with single-joint (SJ or multi-joint exercises (MJ on VO2max, muscle strength and body composition in physically active males. Thirty-six participants were divided in two groups: SJ group (n = 18, 182.1 ± 5.2, 80.03 ± 2.78 kg, 23.5 ± 2.7 years exercised with only SJ exercises (e.g., dumbbell fly, knee extension, etc. and MJ group (n = 18, 185.3 ± 3.6 cm, 80.69 ± 2.98 kg, 25.5 ± 3.8 years with only MJ exercises (e.g., bench press, squat, etc.. The total work volume (repetitions × sets × load was equated between groups. Training was performed three times a week for 8 weeks. Before and after the training period, participants were tested for VO2max, body composition, 1 RM on the bench press, knee extension and squat. Analysis of covariance (ANCOVA was used to compare post training values between groups, using baseline values as covariates. According to the results, both groups decreased body fat and increased fat free mass with no difference between them. Whilst both groups significantly increased cardiorespiratory fitness and maximal strength, the improvements in MJ group were higher than for SJ in VO2max (5.1 and 12.5% for SJ and MJ, bench press 1 RM (8.1 and 10.9% for SJ and MJ, knee extension 1 RM (12.4 and 18.9% for SJ and MJ and squat 1 RM (8.3 and 13.8% for SJ and MJ. In conclusion, when total work volume was equated, RT programs involving MJ exercises appear to be more efficient for improving muscle strength and maximal oxygen consumption than programs involving SJ exercises, but no differences were found for body composition.

  15. Change in regional pulmonary perfusion as a result of posture and lung volume assessed using technetium-99m macroaggregated albumin single-photon emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kosuda, Shigeru; Kusano, Shoichi [Department of Radiology, National Defense Medical College, Tokorozawa (Japan); Kobayashi, Hideo [Department of Internal Medicine, National Defense Medical College, Tokorozawa (Japan)

    2000-05-01

    The purpose of this study was to evaluate the effects of gravity and lung volume on regional pulmonary perfusion using technetium-99m macroaggregated albumin ({sup 99m}Tc MAA) single-photon emission tomography (SPET). Twenty-five subjects were classified into three groups according to their position during the injection of the tracer [11 subjects sitting, six supine and eight both supine and prone (S+P) positions]. All of these subjects were injected with the tracer during normal tidal breathing. In the S+P group, half of the tracer was injected while the subject was in each position. The remaining 11 subjects were classified into two groups according to their lung volume during the injection. Supine patients were instructed to hold their breath at residual volume (RV) (five subjects) or total lung capacity (TLC) (six subjects) while receiving the tracer injection. A region of interest with a ventrodorsal axis was defined in the centre of each lung. Profile curves were produced by plotting and normalizing the perfusion values as a percentage of the maximum value. The perfusion distributions for the sitting and S+P positions and at RV were relatively uniform. However, the distributions for the supine position and at TLC showed a gravitational influence [sitting vs TLC: 87.8%{+-}10.4% vs 67.3%{+-}8.7% for % maximum perfusion at +5 pixels from the midpoint of the upper lobe (P<0.00002)]. The gravity-related perfusion inhomogeneity was more prominent in the lower lobe than in the upper lobe. It is concluded that the physiological vertical gravitational gradient should be taken into consideration during the interpretation of lung SPET images. Preferably, patients should be injected with the tracer twice, once in the supine position and once in the prone position, while breathing normally. Alternatively, they may be injected with the tracer once while in the supine position and holding their breath at RV. Either of these protocols should ensure a uniform distribution of

  16. Heat exchanger

    International Nuclear Information System (INIS)

    Watabe, Ichiro.

    1996-01-01

    An inner cylinder is disposed coaxially in a vertical vessel, and a plurality of heat transfer pipes are wound spirally on the outer circumference of the inner cylinder. High temperature sodium descends on the outer side of the inner cylinder while exchanging heat with water in the heat transfer pipes and becomes low temperature sodium. The low temperature sodium turns at the lower portion of the vessel, rises in a sodium exit pipe inserted to the inner cylinder and is discharged from the top of the vessel to the outside of the vessel. A portion of a cover gas (an inert gas such as argon) filled to the upper portion of the vessel intrudes into the space between the outer circumference of the sodium exit pipe and the inner circumference of the inner cylinder to form a heat insulation layer of the inert gas. This prevents heat exchange between the high temperature sodium before heat exchange and low temperature sodium after heat exchange. The heat exchanger is used as a secondary heat exchanger for coolants (sodium) of an FBR type reactor. (I.N.)

  17. A Direct Heat Exchanger Unit used for Domestic Hot Water Supply in a Single-family House Supplied by Low Energy District Heating

    DEFF Research Database (Denmark)

    Brand, Marek; Thorsen, Jan Eric; Svendsen, Svend

    2010-01-01

    on the testing of the dynamic behaviour of an Instantaneous Heat Exchanger Unit(IHEU) designed for DHW heating and space heating in detached family houses supplied by LEDH ensuring an entry-to-substation temperature of 51 °C. We measured the time it takes for the IHEU to produce DHW with a temperature of 42 °C......The increasing number of new and renovated buildings with reduced heating requirements will soon make traditional District Heating (DH) systems uneconomic. To keep DH competitive in the future, the heat loss in DH networks needs to be reduced. One option is to reduce the supply temperature of DH...... as much as possible. This requires a review of the behaviour of the whole domestic hot water (DHW) supply system with focus on the user comfort and overall costs. This paper describes some practical approaches to the implementation of this Low Energy District Heating (LEDH) concept. It reports...

  18. Solvent exchange in a metal–organic framework single crystal monitored by dynamic in situ X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Cox, Jordan M.; Walton, Ian M.; Bateman, Gage; Benson, Cassidy A.; Mitchell, Travis; Sylvester, Eric; Chen, Yu-Sheng; Benedict, Jason B. (UC); (Buffalo)

    2017-07-25

    Understanding the processes by which porous solid-state materials adsorb and release guest molecules would represent a significant step towards developing rational design principles for functional porous materials. To elucidate the process of liquid exchange in these materials, dynamicin situX-ray diffraction techniques have been developed which utilize liquid-phase chemical stimuli. Using these time-resolved diffraction techniques, the ethanol solvation process in a flexible metal–organic framework [Co(AIP)(bpy)0.5(H2O)]·2H2O was examined. The measurements provide important insight into the nature of the chemical transformation in this system including the presence of a previously unreported neat ethanol solvate structure.

  19. Retrospective study of renal distribution volume with DTPA-99mTc: performance of single plasma method for glomerular filtration rate estimation

    International Nuclear Information System (INIS)

    Legendre, J.M.; Cledes, J.; Morin, J.F.; Morin, P.P.

    1997-01-01

    169 glomerular filtration rate (GFR) measurements, performed in clinical practice, were analysed for estimation of GFR by several common methods. In one half of patients, we observed that early (2-3-4 hours) and tardive (3-4-5 hours three point plasma methods were highly correlated, r = 0,998 (n = 82). Even if regression line significantly differed from identify, differences between methods were low (-6, 1 to + 4,4 mL/min/1,73 m 2 ). Method with urinary collection was also correlated to plasma methods (r = 0,920 in both cases). Plasma based mean values were higher than that for urinary by 3,6 mL/min/1,73 m 2 (2-3-4 hours) and 3, 1 (3-4-5 hours). Using plasma GFR values and distribution volume, linear and quadratic regressions were tested for GFR = f (V) and GFR = f (In (V). The lowest observed standard deviation (3,6 mL/min; n = 82) was for GFR 234 = f (V 4h ) using a quadratic equation. This was applied to the second patient group for GFR estimation with 4 hours single point plasma method. Estimations were compared to GFR plasma values. For comparison, GFR estimations were also obtained using the Christensen's equation. (authors)

  20. Markers of biological stress in response to a single session of high-intensity interval training and high-volume training in young athletes.

    Science.gov (United States)

    Kilian, Yvonne; Engel, Florian; Wahl, Patrick; Achtzehn, Silvia; Sperlich, Billy; Mester, Joachim

    2016-12-01

    The aim of the present study was to compare the effects of high-intensity interval training (HIIT) vs high-volume training (HVT) on salivary stress markers [cortisol (sC), testosterone (sT), alpha-amylase (sAA)], metabolic and cardiorespiratory response in young athletes. Twelve young male cyclists (14 ± 1 years; 57.9 ± 9.4 mL min -1  kg -1 peak oxygen uptake) performed one session of HIIT (4 × 4 min intervals at 90-95 % peak power output separated by 3 min of active rest) and one session of HVT (90 min constant load at 60 % peak power output). The levels of sC, sT, their ratio (sT/sC) and sAA were determined before and 0, 30, 60, 180 min after each intervention. Metabolic and cardiorespiratory stress was characterized by blood lactate, blood pH, respiratory exchange ratio (RER) and heart rate (HR), oxygen uptake ([Formula: see text]), ventilation (V E ) and ventilatory equivalent (V E /[Formula: see text]). sC increased 30 and 60 min after HIIT. However, 180 min post exercise, sC decreased below baseline levels in both conditions. sT increased 0 and 30 min after HIIT and 0 min after HVT. sAA and sT/sC ratio did not change significantly over time in HIIT nor HVT. Metabolic and cardiorespiratory stress, evidenced by blood lactate, HR, [Formula: see text], V E , and V E /[Formula: see text] was higher during HIIT compared to HVT. The metabolic and cardiorespiratory stress during HIIT was higher compared to HVT, but based on salivary analyses (cortisol, testosterone, alpha-amylase), we conclude no strong acute catabolic effects neither by HIIT nor by HVT.

  1. Hydrogen exchange

    DEFF Research Database (Denmark)

    Jensen, Pernille Foged; Rand, Kasper Dyrberg

    2016-01-01

    Hydrogen exchange (HX) monitored by mass spectrometry (MS) is a powerful analytical method for investigation of protein conformation and dynamics. HX-MS monitors isotopic exchange of hydrogen in protein backbone amides and thus serves as a sensitive method for probing protein conformation...... and dynamics along the entire protein backbone. This chapter describes the exchange of backbone amide hydrogen which is highly quenchable as it is strongly dependent on the pH and temperature. The HX rates of backbone amide hydrogen are sensitive and very useful probes of protein conformation......, as they are distributed along the polypeptide backbone and form the fundamental hydrogen-bonding networks of basic secondary structure. The effect of pressure on HX in unstructured polypeptides (poly-dl-lysine and oxidatively unfolded ribonuclease A) and native folded proteins (lysozyme and ribonuclease A) was evaluated...

  2. Direct versus ligand-exchange synthesis of [PtAg28(BDT)12(TPP)4]4-nanoclusters: effect of a single-atom dopant on the optoelectronic and chemical properties.

    Science.gov (United States)

    Bootharaju, Megalamane S; Kozlov, Sergey M; Cao, Zhen; Harb, Moussab; Parida, Manas R; Hedhili, Mohamed N; Mohammed, Omar F; Bakr, Osman M; Cavallo, Luigi; Basset, Jean-Marie

    2017-07-13

    Heteroatom doping of atomically precise nanoclusters (NCs) often yields a mixture of doped and undoped products of single-atom difference, whose separation is extremely difficult. To overcome this challenge, novel synthesis methods are required to offer monodisperse doped NCs. For instance, the direct synthesis of PtAg 28 NCs produces a mixture of [Ag 29 (BDT) 12 (TPP) 4 ] 3- and [PtAg 28 (BDT) 12 (TPP) 4 ] 4- NCs (TPP: triphenylphosphine; BDT: 1,3-benzenedithiolate). Here, we designed a ligand-exchange (LE) strategy to synthesize single-sized, Pt-doped, superatomic Ag NCs [PtAg 28 (BDT) 12 (TPP) 4 ] 4- by LE of [Pt 2 Ag 23 Cl 7 (TPP) 10 ] NCs with BDTH 2 (1,3-benzenedithiol). The doped NCs were thoroughly characterized by optical and photoelectron spectroscopy, mass spectrometry, total electron count, and time-dependent density functional theory (TDDFT). We show that the Pt dopant occupies the center of the PtAg 28 cluster, modulates its electronic structure and enhances its photoluminescence intensity and excited-state lifetime, and also enables solvent interactions with the NC surface. Furthermore, doped NCs showed unique reactivity with metal ions - the central Pt atom of PtAg 28 could not be replaced by Au, unlike the central Ag of Ag 29 NCs. The achieved synthesis of single-sized PtAg 28 clusters will facilitate further applications of the LE strategy for the exploration of novel multimetallic NCs.

  3. Direct versus ligand-exchange synthesis of [PtAg28(BDT)12(TPP)4]4− nanoclusters: effect of a single-atom dopant on the optoelectronic and chemical properties

    KAUST Repository

    Bootharaju, Megalamane Siddaramappa

    2017-06-07

    Heteroatom doping of atomically precise nanoclusters (NCs) often yields a mixture of doped and undoped products of single-atom difference, whose separation is extremely difficult. To overcome this challenge, novel synthesis methods are required to offer monodisperse doped NCs. For instance, the direct synthesis of PtAg28 NCs produces a mixture of [Ag29(BDT)12(TPP)4]3- and [PtAg28(BDT)12(TPP)4]4- NCs (TPP: triphenylphosphine; BDT: 1,3-benzenedithiolate). Here, we designed a ligand-exchange (LE) strategy to synthesize single-sized, Pt-doped, superatomic Ag NCs [PtAg28(BDT)12(TPP)4]4- by LE of [Pt2Ag23Cl7(TPP)10] NCs with BDTH2 (1,3-benzenedithiol). The doped NCs were thoroughly characterized by optical and photoelectron spectroscopy, mass spectrometry, total electron count, and time-dependent density functional theory (TDDFT). We show that the Pt dopant occupies the center of the PtAg28 cluster, modulates its electronic structure and enhances its photoluminescence intensity and excited-state lifetime, and also enables solvent interactions with the NC surface. Furthermore, doped NCs showed unique reactivity with metal ions - the central Pt atom of PtAg28 could not be replaced by Au, unlike the central Ag of Ag29 NCs. The achieved synthesis of single-sized PtAg28 clusters will facilitate further applications of the LE strategy for the exploration of novel multimetallic NCs.

  4. Effect of a heat and moisture exchanger on heat loss in isoflurane-anesthetized dogs undergoing single-limb orthopedic procedures.

    Science.gov (United States)

    Hofmeister, Erik H; Brainard, Benjamin M; Braun, Christina; Figueiredo, Juliana P

    2011-12-15

    To determine whether a heat and moisture exchange device (HME) prevents a decrease in body temperature in isoflurane-anesthetized dogs undergoing orthopedic procedures. Blinded randomized controlled clinical trial. 60 privately owned dogs weighing at least 15 kg (33 lb). Dogs were randomly assigned to 1 of 3 treatment groups (n = 20/group): HME placed immediately after anesthetic induction with isoflurane, after transfer to the operating room, or not at all. The device consisted of a hygroscopic filter placed between the endotracheal tube and the Y piece of the anesthesia circuit. Each dog was positioned on a circulating warm water blanket and had a forced-air warming blanket placed over its body. Body temperature was monitored after transfer to the operating room with a probe placed in the thoracic aspect of the esophagus. Study groups did not differ significantly with respect to body weight, body condition score, reproductive status, breed, surgical procedure, preoperative sedative and opioid administration, anesthetic induction drug, local nerve block technique, or operating room assignment. There were no significant differences among groups in esophageal temperature variables, interval between anesthetic induction and surgery, surgery duration, anesthesia duration, or oxygen flow rate. However, the relationship between temperature delta and body weight was significant and relevant (R(2) = 0.23), as was the association between temperature nadir and body weight (R(2)= 0.10). As body weight increased, the temperature delta decreased and temperature nadir increased. No other significant relationships were identified. Inclusion of an HME in healthy dogs undergoing anesthesia for an elective orthopedic surgery did not facilitate maintenance of body temperature throughout the procedure.

  5. The exchangeability of shape

    Directory of Open Access Journals (Sweden)

    Kaba Dramane

    2010-10-01

    Full Text Available Abstract Background Landmark based geometric morphometrics (GM allows the quantitative comparison of organismal shapes. When applied to systematics, it is able to score shape changes which often are undetectable by traditional morphological studies and even by classical morphometric approaches. It has thus become a fast and low cost candidate to identify cryptic species. Due to inherent mathematical properties, shape variables derived from one set of coordinates cannot be compared with shape variables derived from another set. Raw coordinates which produce these shape variables could be used for data exchange, however they contain measurement error. The latter may represent a significant obstacle when the objective is to distinguish very similar species. Results We show here that a single user derived dataset produces much less classification error than a multiple one. The question then becomes how to circumvent the lack of exchangeability of shape variables while preserving a single user dataset. A solution to this question could lead to the creation of a relatively fast and inexpensive systematic tool adapted for the recognition of cryptic species. Conclusions To preserve both exchangeability of shape and a single user derived dataset, our suggestion is to create a free access bank of reference images from which one can produce raw coordinates and use them for comparison with external specimens. Thus, we propose an alternative geometric descriptive system that separates 2-D data gathering and analyzes.

  6. Heat exchangers

    International Nuclear Information System (INIS)

    1975-01-01

    The tubes of a heat exchanger tube bank have a portion thereof formed in the shape of a helix, of effective radius equal to the tube radius and the space between two adjacent tubes, to tangentially contact the straight sections of the tubes immediately adjacent thereto and thereby provide support, maintain the spacing and account for differential thermal expansion thereof

  7. Heat exchanger

    International Nuclear Information System (INIS)

    Wolowodiuk, W.

    1976-01-01

    A heat exchanger of the straight tube type is described in which different rates of thermal expansion between the straight tubes and the supply pipes furnishing fluid to those tubes do not result in tube failures. The supply pipes each contain a section which is of helical configuration

  8. Exchange Options

    NARCIS (Netherlands)

    Jamshidian, F.

    2007-01-01

    The contract is described and market examples given. Essential theoretical developments are introduced and cited chronologically. The principles and techniques of hedging and unique pricing are illustrated for the two simplest nontrivial examples: the classical Black-Scholes/Merton/Margrabe exchange

  9. Analysis of regional cerebral blood flow and distribution volume in Machado-Joseph disease by iodine-123I IMP single photon emission computed tomography

    International Nuclear Information System (INIS)

    Hayashi, Tsunemi; Nakajima, Takashi; Fukuhara, Nobuyoshi

    2001-01-01

    Machado-Joseph disease (MJD) is an autosomal dominant spinocerebellar ataxia. Its clinical features vary greatly in different generations of the same family. Regional cerebral blood flow (rCBF) and distribution volume (V d ) in the pons, cerebellum, and cerebral cortex were measured in 12 patients with MJD by autoradiography (ARG) and the table look-up (TLU) method of iodine-123 IMP ( 123 I-IMP) single photon emission computed tomography (SPECT). Representative cases were as follows: A 46-year-old woman first experienced gait ataxia at age 38. Computed tomography (CT) and magnetic resonance imaging (MRI) showed no atrophy in the pons or cerebellum, but rCBF measured by the 123 I-IMP SPECT ARG method detected hypoperfusion in the pons, and cerebellar vermis and hemisphere. A 76-year-old woman first experienced gait ataxia at age 69. CT and MRI findings showed severe atrophy in the pons, and cerebellar vermis and hemisphere. Moreover, rCBF was decreased in the pons, whereas it was not decreased in the cerebellar vermis and hemisphere. In the pons of patients with MJD, rCBF was markedly decreased regardless of disease severity. Because this SPECT finding for the pons looked like a 'dot', we have called it the 'pontine dot sign'. In the MJD group, rCBF was significantly decreased in the pons (Student's t test, p d was also significantly decreased in the pons (p d for the pons and age at onset (r=0.59, p d in the cerebellar hemispheres and International Cooperative Ataxia Rating Scale (r=0.644, p d obtained by 123 I-IMP SPECT for patients with MJD identified by gene analysis. Our study shows that SPECT measurement of rCBF and V d is useful for understanding the pathophysiology of MJD. (author)

  10. Role of Magnetic Exchange Interactions in the Magnetization Relaxation of {3d-4f} Single-Molecule Magnets: A Theoretical Perspective.

    Science.gov (United States)

    Singh, Saurabh Kumar; Beg, Mohammad Faizan; Rajaraman, Gopalan

    2016-01-11

    Combined density functional and ab initio calculations are performed on two isomorphous tetranuclear {Ni3 (III) Ln(III) } star-type complexes [Ln=Gd (1), Dy (2)] to shed light on the mechanism of magnetic exchange in 1 and the origin of the slow magnetization relaxation in complex 2. DFT calculations correctly reproduce the sign and magnitude of the J values compared to the experiments for complex 1. Acute ∢Ni-O-Gd bond angles present in 1 instigate a significant interaction between the 4fxyz orbital of the Gd(III) ion and 3d${{_{x{^{2}}- y{^{2}}}}}$ orbital of the Ni(II) ions, leading to rare and strong antiferromagnetic Ni⋅⋅⋅Gd interactions. Calculations reveal the presence of a strong next-nearest-neighbour Ni⋅⋅⋅Ni antiferromagnetic interaction in complex 1 leading to spin frustration behavior. CASSCF+RASSI-SO calculations performed on complex 2 suggest that the octahedral environment around the Dy(III) ion is neither strong enough to stabilize the mJ |±15/2〉 as the ground state nor able to achieve a large ground-state-first-excited-state gap. The ground-state Kramers doublet for the Dy(III) ion is found to be the mJ |±13/2〉 state with a significant transverse anisotropy, leading to very strong quantum tunneling of magnetization (QTM). Using the POLY_ANISO program, we have extracted the JNiDy interaction as -1.45 cm(-1) . The strong Ni⋅⋅⋅Dy and next-nearest-neighbour Ni⋅⋅⋅Ni interactions are found to quench the QTM to a certain extent, resulting in zero-field SMM behavior for complex 2. The absence of any ac signals at zero field for the structurally similar [Dy(AlMe4 )3 ] highlights the importance of both the Ni⋅⋅⋅Dy and the Ni⋅⋅⋅Ni interactions in the magnetization relaxation of complex 2. To the best of our knowledge, this is the first time that the roles of both the Ni⋅⋅⋅Dy and Ni⋅⋅⋅Ni interactions in magnetization relaxation of a {3d-4f} molecular magnet have been established. © 2016

  11. Ion exchange equilibrium constants

    CERN Document Server

    Marcus, Y

    2013-01-01

    Ion Exchange Equilibrium Constants focuses on the test-compilation of equilibrium constants for ion exchange reactions. The book first underscores the scope of the compilation, equilibrium constants, symbols used, and arrangement of the table. The manuscript then presents the table of equilibrium constants, including polystyrene sulfonate cation exchanger, polyacrylate cation exchanger, polymethacrylate cation exchanger, polysterene phosphate cation exchanger, and zirconium phosphate cation exchanger. The text highlights zirconium oxide anion exchanger, zeolite type 13Y cation exchanger, and

  12. Heat exchanger

    International Nuclear Information System (INIS)

    Bennett, J.C.

    1975-01-01

    A heat exchanger such as forms, for example, part of a power steam boiler is made up of a number of tubes that may be arranged in many different ways, and it is necessary that the tubes be properly supported. The means by which the tubes are secured must be as simple as possible so as to facilitate construction and must be able to continue to function effectively under the varying operating conditions to which the heat exchanger is subject. The arrangement described is designed to meet these requirements, in an improved way. The tubes are secured to a member extending past several tubes and abutment means are provided. At least some of the abutment means comprise two abutment pieces and a wedge secured to the supporting member, that acts on these pieces to maintain the engagement. (U.K.)

  13. Exchange of current BPA surplus power for future power from certain companies' share of WNP-3 to settle a dispute over construction delay. Record of decision. Volume II. Exhibits

    International Nuclear Information System (INIS)

    1985-01-01

    This exchange is between BPA and Portland General Electric Company, Puget Sound Power and Light Company, and the Washington Water Power Company. Pacific Power and Light Company (Pacific) is not initially a party to the exchange. Pacific may at any time prior to January 1, 1994 elect on at least 12 months notice to enter the exchange provided that if BPA determines to resume full plant construction Pacific must elect or forego the option within 6 months after construction is resumed. If the plant is terminated at a time when the option has not been exercised, the option may not thereafter be exercised. If Pacific elects to make the exchange effective and the plant is later terminated prior to the effective data of the exchange, the exchange will become effective on the specified data, unless, prior to such data. Pacific notifies BPA that is rescinds such prior election

  14. Effects of ambient temperature and oxygen concentration on diesel spray combustion using a single-nozzle injector in a constant volume combustion chamber

    KAUST Repository

    Jing, Wei

    2013-09-02

    This work investigates the effects of ambient conditions on diesel spray combustion in an optically accessible, constant volume chamber using a single-nozzle fuel injector. The ambient O2 concentration was varied between five discrete values from 10% to 21% and three different ambient temperatures (800 K, 1000 K, and 1200 K). These conditions simulate different exhaust gas recirculation (EGR) levels and ambient temperatures in diesel engines. Both conventional diesel combustion and low temperature combustion (LTC) modes were observed under these conditions. A transient analysis and a quasi-steady state analysis are employed in this article. The transient analysis focuses on the flame development from beginning to the end, illustrating how the flame structure changes during this process; the quasi-steady state analysis focuses on the stable flame structure. The transient analysis was conducted using high-speed imaging of both OH* chemiluminescence and natural luminosity (NL). In addition, three different images were acquired using an ICCD camera, corresponding to OH* chemiluminescence, narrow-band flame emission at 430 nm (Band A) and at 470 nm (Band B), and were used to investigate the quasi-steady state combustion process. From the transient analysis, it was found that the NL signal becomes stronger and confined to narrow regions when the temperature and O2 concentration increase during the development of flame. The OH* intensity is much lower for the 10% ambient O2 and 800 K conditions compared to the higher temperatures and O2 levels. This implies the occurrence of LTC under these conditions. Results from the quasi-steady combustion stage indicate that high-temperature reactions effectively oxidize the soot in the downstream locations where only OH* signal is observed. In addition, an area was calculated for each spectral region, and results show that the area of Band A and Band B emissions in these images is larger than the area of OH* emissions at the lower O2

  15. 3.5 Radiation stability of ion exchangers

    International Nuclear Information System (INIS)

    Marhol, M.

    1976-01-01

    The main knowledge is summed up of the radiation stability of ion exchangers. No basic changes occur in inorganic ion exchangers with the exception of the exchange capacity at doses of up to 10 9 rad. This also applies to coal-based ion exchangers. Tables are given showing the changes in specific volume, exchange capacity and weight of different types of organic ion exchangers in dependence on the radiation dose. The effects are discussed of the structure of organic cation and anion exchangers, polymeric strong basic anion exchangers, polycondensate anion exchangers and ion exchange membranes on their radiation stability. General experimental procedures are given for laboratory tests of the radiation stability of exchangers. (L.K.)

  16. Exchanging information

    International Nuclear Information System (INIS)

    1971-01-01

    The Agency has a statutory mandate to foster 'the exchange of scientific and technical information on the peaceful uses of atomic energy'. The prime responsibility for this work within the Agency lies with the Division of Scientific and Technical Information, a part of the Department of Technical Operations. The Division accomplishes its task by holding conferences and symposia (Scientific Conferences Section), through the Agency Library, by publishing scientific journals, and through the International Nuclear Information System (INIS). The Computer Section of the Division, which offers services to the Agency as a whole, provides resources for the automation of data storage and retrieval. (author)

  17. Efficacy of sub-Tenon's block using an equal volume of local anaesthetic administered either as a single or as divided doses. A randomised clinical trial.

    LENUS (Irish Health Repository)

    Khan, Ehtesham I

    2009-01-01

    Sub-Tenon\\'s anaesthetic is effective and reliable in producing both akinesia and anaesthesia for cataract surgery. Our clinical experience indicates that it is sometimes necessary when absolute akinesia is required during surgery to augment the block with 1-2 ml of local anaesthetic. Hypothesis was that after first injection some of the volume injected may spill out and before second injection the effect of hyaluronidase has taken place and second volume injectate will have desired effect.

  18. The volume of a soliton

    Energy Technology Data Exchange (ETDEWEB)

    Adam, C., E-mail: adam@fpaxp1.usc.es [Departamento de Física de Partículas, Universidad de Santiago de Compostela and Instituto Galego de Física de Altas Enerxias (IGFAE), E-15782 Santiago de Compostela (Spain); Haberichter, M. [School of Mathematics, Statistics and Actuarial Science, University of Kent, Canterbury, CT2 7NF (United Kingdom); Wereszczynski, A. [Institute of Physics, Jagiellonian University, Lojasiewicza 11, Kraków (Poland)

    2016-03-10

    There exists, in general, no unique definition of the size (volume, area, etc., depending on dimension) of a soliton. Here we demonstrate that the geometric volume (area etc.) of a soliton is singled out in the sense that it exactly coincides with the thermodynamical or continuum-mechanical volume. In addition, this volume may be defined uniquely for rather arbitrary solitons in arbitrary dimensions.

  19. The volume of a soliton

    International Nuclear Information System (INIS)

    Adam, C.; Haberichter, M.; Wereszczynski, A.

    2016-01-01

    There exists, in general, no unique definition of the size (volume, area, etc., depending on dimension) of a soliton. Here we demonstrate that the geometric volume (area etc.) of a soliton is singled out in the sense that it exactly coincides with the thermodynamical or continuum-mechanical volume. In addition, this volume may be defined uniquely for rather arbitrary solitons in arbitrary dimensions.

  20. Exchange of Identical Particles in Two Dimensions

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 6; Issue 2. Exchange of Identical Particles in Two Dimensions. P Ramadevi. General Article Volume 6 Issue 2 February 2001 pp 23-28. Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/reso/006/02/0023-0028 ...

  1. Navvus FFR to reduce CONTRAst, Cost and radiaTion (CONTRACT); insights from a single-centre clinical and economical evaluation with the RXi Rapid-Exchange FFR device.

    Science.gov (United States)

    Masdjedi, Kaneshka; Van Mieghem, Nicolas M; Diletti, Roberto; van Geuns, Robert-Jan; de Jaegere, Peter; Regar, Evelyn; Zijlstra, Felix; van Domburg, Ron T; Daemen, Joost

    2017-04-15

    To assess whether the RXi Navvus system compared to the use of standard Fractional Flow Reserve (FFR) wires reduces total contrast volume, radiation and overall study cost in a real world patient population referred for coronary angiography or percutaneous coronary intervention. FFR is the mainstay of functional hemodynamic assessment of coronary artery lesions. The RXi Navvus system (ACIST Medical Systems, Eden Prairie, MN) is a monorail microcatheter with FFR-measurement capability through optical pressure sensor technology. This is an investigator-initiated, prospective, single-center, observational cohort study. A total of 238 patients were enrolled, 97 patients with Navvus and 141 with conventional pressure-wire based FFR (PW-FFR). Final analyses were performed on the cohort in which only 1 device was used (82 Navvus procedures vs. 136 PW-FFR procedures). No significant differences were found in the total amount of contrast used (150±77 vs 147±79ml; p=0.81), radiation use (6200±4601 vs. 5076±4655 centiG∗cm 2 ; p=0.09) or costs (€1994,- vs. €1930,-; p=0.32) in the Navvus vs. PW-FFR groups respectively. No significant differences were found in the amount of contrast used, total procedural costs or radiation when the Navvus system was used as compared to conventional FFR wires. CONTRACT is an investigator-initiated, prospective, single-center, observational cohort study that evaluated whether the RXi Navvus system compared to the use of standard Fractional Flow Reserve (FFR) wires reduces total contrast volume, radiation and overall study cost in a real world patient population referred for coronary angiography or percutaneous coronary intervention. Use of the RXi Navvus system was associated with comparable procedural costs, amount of radiation and contrast used as compared to PW-FFR systems. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  2. Matchmaker Exchange.

    Science.gov (United States)

    Sobreira, Nara L M; Arachchi, Harindra; Buske, Orion J; Chong, Jessica X; Hutton, Ben; Foreman, Julia; Schiettecatte, François; Groza, Tudor; Jacobsen, Julius O B; Haendel, Melissa A; Boycott, Kym M; Hamosh, Ada; Rehm, Heidi L

    2017-10-18

    In well over half of the individuals with rare disease who undergo clinical or research next-generation sequencing, the responsible gene cannot be determined. Some reasons for this relatively low yield include unappreciated phenotypic heterogeneity; locus heterogeneity; somatic and germline mosaicism; variants of uncertain functional significance; technically inaccessible areas of the genome; incorrect mode of inheritance investigated; and inadequate communication between clinicians and basic scientists with knowledge of particular genes, proteins, or biological systems. To facilitate such communication and improve the search for patients or model organisms with similar phenotypes and variants in specific candidate genes, we have developed the Matchmaker Exchange (MME). MME was created to establish a federated network connecting databases of genomic and phenotypic data using a common application programming interface (API). To date, seven databases can exchange data using the API (GeneMatcher, PhenomeCentral, DECIPHER, MyGene2, matchbox, Australian Genomics Health Alliance Patient Archive, and Monarch Initiative; the latter included for model organism matching). This article guides usage of the MME for rare disease gene discovery. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley and Sons, Inc.

  3. Enhanced DOC removal using anion and cation ion exchange resins.

    Science.gov (United States)

    Arias-Paic, Miguel; Cawley, Kaelin M; Byg, Steve; Rosario-Ortiz, Fernando L

    2016-01-01

    Hardness and DOC removal in a single ion exchange unit operation allows for less infrastructure, is advantageous for process operation and depending on the water source, could enhance anion exchange resin removal of dissolved organic carbon (DOC). Simultaneous application of cationic (Plus) and anionic (MIEX) ion exchange resin in a single contact vessel was tested at pilot and bench scales, under multiple regeneration cycles. Hardness removal correlated with theoretical predictions; where measured hardness was between 88 and 98% of the predicted value. Comparing bench scale DOC removal of solely treating water with MIEX compared to Plus and MIEX treated water showed an enhanced DOC removal, where removal was increased from 0.5 to 1.25 mg/L for the simultaneous resin application compared to solely applying MIEX resin. A full scale MIEX treatment plant (14.5 MGD) reduced raw water DOC from 13.7 mg/L to 4.90 mg/L in the treated effluent at a bed volume (BV) treatment rate of 800, where a parallel operation of a simultaneous MIEX and Plus resin pilot (10 gpm) measured effluent DOC concentrations of no greater than 3.4 mg/L, even at bed volumes of treatment 37.5% greater than the full scale plant. MIEX effluent compared to simultaneous Plus and MIEX effluent resulted in differences in fluorescence intensity that correlated to decreases in DOC concentration. The simultaneous treatment of Plus and MIEX resin produced water with predominantly microbial character, indicating the enhanced DOC removal was principally due to increased removal of terrestrially derived organic matter. The addition of Plus resin to a process train with MIEX resin allows for one treatment process to remove both DOC and hardness, where a single brine waste stream can be sent to sewer at a full-scale plant, completely removing lime chemical addition and sludge waste disposal for precipitative softening processes. Published by Elsevier Ltd.

  4. Electrodialytic decontamination of spent ion exchange resins

    International Nuclear Information System (INIS)

    Nott, B.R.

    1982-01-01

    Development of a novel electrodialytic decontamination process for the selective removal of radioactive Cs from spent ion exchange resins containing large amounts of Li is described. The process involves passage of a dc electric current through a bed of the spent ion exchange resin in a specially designed electrodialytic cell. The radiocesium so removed from a volume of the spent resin is concentrated onto a much smaller volume of a Cs selective sorbent to achieve a significant radioactive waste volume reduction. Technical feasibility of the electrodialytic resin decontamination process has been demonstrated on a bench scale with a batch of simulated spent ion exchange resin and using potassium cobalt ferrocyanide as the Cs selective sorbent. A volume reduction factor between 10 and 17 has been estimated. The process appears to be economically attractive. Improvements in process economics can be expected from optimization of the process. Other possible applications of the EDRD process have been identified

  5. Numerical simulation of tubes-in-tube heat exchanger in a mixed refrigerant Joule-Thomson cryocooler

    Science.gov (United States)

    Damle, R. M.; Ardhapurkar, P. M.; Atrey, M. D.

    2017-02-01

    Mixed refrigerant Joule-Thomson (MRJT) cryocoolers can produce cryogenic temperatures with high efficiency and low operating pressures. As compared to the high system pressures of around 150-200 bar with nitrogen, the operational pressures with non-azeotropic mixtures (e.g., nitrogen-hydrocarbons) come down to 10-25 bar. With mixtures, the heat transfer in the recuperative heat exchanger takes place in the two-phase region. The simultaneous boiling and condensation of the cold and hot gas streams lead to higher heat transfer coefficients as compared to single phase heat exchange. The two-phase heat transfer in the recuperative heat exchanger drastically affects the performance of a MRJT cryocooler. In this work, a previously reported numerical model for a simple tube-in-tube heat exchanger is extended to a multi tubes-in-tube heat exchanger with a transient formulation. Additionally, the J-T expansion process is also considered to simulate the cooling process of the heat exchanger from ambient temperature conditions. A tubes-in-tube heat exchanger offers more heat transfer area per unit volume resulting in a compact design. Also, the division of flow in multiple tubes reduces the pressure drop in the heat exchanger. Simulations with different mixtures of nitrogen-hydrocarbons are carried out and the numerical results are compared with the experimental data.

  6. Volume regulation in epithelia

    DEFF Research Database (Denmark)

    Larsen, Erik Hviid; Hoffmann, Else Kay

    2016-01-01

    We review studies on regulatory volume decrease (RVD) and regulatory volume increase (RVI) of major ion and water transporting vertebrate epithelia. The rate of RVD and RVI is faster in cells of high osmotic permeability like amphibian gallbladder and mammalian proximal tubule as compared...... function of iso-osmotic fluid transport that depends on Na+ recirculation. The causative relationship is discussed for a fluid-absorbing and a fluid-secreting epithelium of which the Na+ recirculation mechanisms have been identified. A large number of transporters and ion channels involved in cell volume...... regulation are cloned. The volume-regulated anion channel (VRAC) exhibiting specific electrophysiological characteristics seems exclusive to serve cell volume regulation. This is contrary to K+ channels as well as cotransporters and exchange mechanisms that may serve both transepithelial transport and cell...

  7. Segmented heat exchanger

    Science.gov (United States)

    Baldwin, Darryl Dean; Willi, Martin Leo; Fiveland, Scott Byron; Timmons, Kristine Ann

    2010-12-14

    A segmented heat exchanger system for transferring heat energy from an exhaust fluid to a working fluid. The heat exchanger system may include a first heat exchanger for receiving incoming working fluid and the exhaust fluid. The working fluid and exhaust fluid may travel through at least a portion of the first heat exchanger in a parallel flow configuration. In addition, the heat exchanger system may include a second heat exchanger for receiving working fluid from the first heat exchanger and exhaust fluid from a third heat exchanger. The working fluid and exhaust fluid may travel through at least a portion of the second heat exchanger in a counter flow configuration. Furthermore, the heat exchanger system may include a third heat exchanger for receiving working fluid from the second heat exchanger and exhaust fluid from the first heat exchanger. The working fluid and exhaust fluid may travel through at least a portion of the third heat exchanger in a parallel flow configuration.

  8. Charge exchange between singly ionized helium ions

    International Nuclear Information System (INIS)

    Choi, B.H.; Poe, R.T.; Tang, K.T.

    1978-01-01

    The plane-wave Born approximation was used to evaluate the charge transfer cross sections for the reaction He + + He + → He ++ + He. The charge transfer cross section is graphed as a function of incident energy and compared with experimental measurements

  9. Preliminary recommendations on the design of the characterization program for the Hanford Site single-shell tanks: A system analysis. Volume 2, Closure-related analyte priorities, concentration thresholds, and detection limit goals based on public health concerns

    Energy Technology Data Exchange (ETDEWEB)

    Buck, J.W.; Peffers, M.S.; Hwang, S.T.

    1991-11-01

    The work described in this volume was conducted by Pacific Northwest Laboratory to provide preliminary recommendations on data quality objectives (DQOs) to support the Waste Characterization Plan (WCP) and closure decisions for the Hanford Site single-shell tanks (SSTs). The WCP describes the first of a two-phase characterization program that will obtain information to assess and implement disposal options for SSTs. This work was performed for the Westinghouse Hanford Company (WHC), the current operating contractor on the Hanford Site. The preliminary DQOs contained in this volume deal with the analysis of SST wastes in support of the WCP and final closure decisions. These DQOs include information on significant contributors and detection limit goals (DLGs) for SST analytes based on public health risk.

  10. Fair Exchange in Strand Spaces

    Directory of Open Access Journals (Sweden)

    Joshua D. Guttman

    2009-10-01

    Full Text Available Many cryptographic protocols are intended to coordinate state changes among principals. Exchange protocols coordinate delivery of new values to the participants, e.g. additions to the set of values they possess. An exchange protocol is fair if it ensures that delivery of new values is balanced: If one participant obtains a new possession via the protocol, then all other participants will, too. Fair exchange requires progress assumptions, unlike some other protocol properties. The strand space model is a framework for design and verification of cryptographic protocols. A strand is a local behavior of a single principal in a single session of a protocol. A bundle is a partially ordered global execution built from protocol strands and adversary activities. The strand space model needs two additions for fair exchange protocols. First, we regard the state as a multiset of facts, and we allow strands to cause changes in this state via multiset rewriting. Second, progress assumptions stipulate that some channels are resilient-and guaranteed to deliver messages-and some principals are assumed not to stop at certain critical steps. This method leads to proofs of correctness that cleanly separate protocol properties, such as authentication and confidentiality, from invariants governing state evolution. G. Wang's recent fair exchange protocol illustrates the approach.

  11. Deuterium exchange in sesamol

    International Nuclear Information System (INIS)

    Hill, R.K.; Vaidya, N.A.; Morton, G.H.

    1982-01-01

    Trifluoroacetic acid-catalyzed exchange of sesamol in 2 H 2 O results in rapid exchange of H-6 and slower exchange of H-2. The deuterium atoms introduced are retained during conversion to the methyl and allyl ethers. (author)

  12. Comparison of the Effect of Pre-operative Single Oral Dose of Tramadol and Famotidine on Gastric Secretions pH and Volume in Patients Scheduled for Laparoscopic Cholecystectomy

    International Nuclear Information System (INIS)

    Khan, M. U.; Aqil, M.; Hussain, A.; Zahrani, T. A.; Hillis, M.

    2015-01-01

    Objective: To evaluate and compare the effects of pre-operative single oral dose of tramadol and famotidine on gastric secretions pH and volume in patients electively scheduled for laparoscopic cholecystectomy. Study Design: Randomized control trial. Place and Duration of Study: Department of Anaesthesia, King Saud University Riyadh, Saudi Arabia, from August 2011 to June 2013. Methodology: Ninety adult, ASA-I and II patients scheduled for laparoscopic cholecystectomy were included in the study. Patients were randomly assigned to receive pre-operatively either placebo (Group-C, n=30), oral tramadol 100 mg (Group-T, n=30) or famotidine 40 mg (Group-F, n=30). After induction of general anaesthesia, gastric fluid was aspirated through orogastric tube. The gastric secretions volume and pH was measured using pH meter. Results:There was no statistically difference between groups in age, weight and gender. The gastric secretions mean pH was 2.06 ± 0.22,2.04 ± 0.20, 5.79 ± 0.77 and volume was 0.59 ± 0.17, 0.59 ± 0.14 and 0.28 ± 0.16 ml/kg in Group-C, Group-T and Group-F respectively. There was a significant statistical difference in the mean pH values between Group-C vs. Group-F (p greater than 0.001) and Group-Tvs. Group-F (p greater than 0.001). Statistically significant difference was also found in the mean gastric secretions volume between Group - C vs. Group-F (p greater than 0.001) and Group-Tvs. Group-F (p greater than 0.001). There was no significant difference in the mean gastric fluid pH values (p=0.99) and mean gastric secretions volume (p=0.99) between Group-Tand Group-C. Conclusion:As compared to famotidine, pre-operative single oral dose of tramadol was unable to elevate the desired level of gastric fluid pH (less than 2.5) and decrease in gastric secretions volume (greater than 0.4ml/kg). (author)

  13. A new family of 1D exchange biased heterometal single-molecule magnets: observation of pronounced quantum tunneling steps in the hysteresis loops of quasi-linear {Mn2Ni3} clusters.

    Science.gov (United States)

    Das, Animesh; Gieb, Klaus; Krupskaya, Yulia; Demeshko, Serhiy; Dechert, Sebastian; Klingeler, Rüdiger; Kataev, Vladislav; Büchner, Bernd; Müller, Paul; Meyer, Franc

    2011-03-16

    First members of a new family of heterometallic Mn/Ni complexes [Mn(2)Ni(3)X(2)L(4)(LH)(2)(H(2)O)(2)] (X = Cl: 1; X = Br: 2) with the new ligand 2-{3-(2-hydroxyphenyl)-1H-pyrazol-1-yl}ethanol (H(2)L) have been synthesized, and single crystals obtained from CH(2)Cl(2) solutions have been characterized crystallographically. The molecular structures feature a quasi-linear Mn(III)-Ni(II)-Ni(II)-Ni(II)-Mn(III) core with six-coordinate metal ions, where elongated axes of all the distorted octahedral coordination polyhedra are aligned parallel and are fixed with respect to each other by intramolecular hydrogen bonds. 1 and 2 exhibit quite strong ferromagnetic exchange interactions throughout (J(Mn-Ni) ≈ 40 K (1) or 42 K (2); J(Ni-Ni) ≈ 22 K (1) or 18 K (2)) that lead to an S(tot) = 7 ground state, and a sizable uniaxial magnetoanisotropy with D(mol) values -0.55 K (1) and -0.45 K (2). These values are directly derived also from frequency- and temperature-dependent high-field EPR spectra. Slow relaxation of the magnetization at low temperatures and single-molecule magnet (SMM) behavior are evident from frequency-dependent peaks in the out-of-phase ac susceptibilities and magnetization versus dc field measurements, with significant energy barriers to spin reversal U(eff) = 27 K (1) and 22 K (2). Pronounced quantum tunnelling steps are observed in the hysteresis loops of the temperature- and scan rate-dependent magnetization data, but with the first relaxation step shifted above (1) or below (2) the zero crossing of the magnetic field, despite the very similar molecular structures. The different behavior of 1 and 2 is interpreted in terms of antiferromagnetic (1) or ferromagnetic (2) intermolecular interactions, which are discussed in view of the subtle differences of intermolecular contacts within the crystal lattice.

  14. Distribution of Functional Liver Volume in Hepatocellular Carcinoma Patients with Portal Vein Tumor Thrombus in the 1st Branch and Main Trunk Using Single Photon Emission Computed Tomography—Application to Radiation Therapy

    Directory of Open Access Journals (Sweden)

    Akira Ikoma

    2011-10-01

    Full Text Available Purpose: To analyze the distribution of functional liver volume (FLV in the margin volume (MV surrounding hepatocellular carcinoma (HCC with portal vein tumor thrombus (PVTT before radiation therapy (RT and to verify the safety of single photon emission computed tomography-based three-dimensional conformal radiotherapy (SPECT-B3DCRT by exploring the relation of FLV in MV to radiation-induced liver disease (RILD. Methods and Materials: Clinical target volume (CTV included main tumor and PVTT, and planning target volume (PTV included CTV with a 10 mm margin. MV was defined as PTV–CTV. FLV ratio in MV was calculated as FLV in MV/MV × 100 (%. The two high-dose beams were planned to irradiate FLV as little as possible. Fifty-seven cases of HCC (26/57, 46%; Child–Pugh grade B with PVTT underwent SPECT-B3DCRT which targeted the CTV to a total dose of 45 Gy/18 fractions. The destructive ratio was defined as radiation induced dysfunctional volume/FLV × 100 (%. Results: We observed a significant negative correlation between FLV ratio in MV and CTV (p < 0.001. Three cases with CTVs of 287, 587 and 1184 cm3 experienced transient RILD. The FLV ratio in MV was highest in patients with RILD: nine patients with CTV of 200–300 cm3, three with CTV of 500–600 cm3, and two with CTV of 1100–1200 cm3. The destructive ratio yielded a mean value of 24.2 ± 1.5%. Conclusions: Radiation planning that takes into account the distribution of FLV appears to result in the least possible RILD.

  15. Proton exchange membrane fuel cells

    CERN Document Server

    Qi, Zhigang

    2013-01-01

    Preface Proton Exchange Membrane Fuel CellsFuel CellsTypes of Fuel CellsAdvantages of Fuel CellsProton Exchange Membrane Fuel CellsMembraneCatalystCatalyst LayerGas Diffusion MediumMicroporous LayerMembrane Electrode AssemblyPlateSingle CellStackSystemCell Voltage Monitoring Module (CVM)Fuel Supply Module (FSM)Air Supply Module (ASM)Exhaust Management Module (EMM)Heat Management Module (HMM)Water Management Module (WMM)Internal Power Supply Module (IPM)Power Conditioning Module (PCM)Communications Module (COM)Controls Module (CM)SummaryThermodynamics and KineticsTheoretical EfficiencyVoltagePo

  16. Inflationary trispectrum from graviton exchange

    DEFF Research Database (Denmark)

    Seery, David; Sloth, Martin Snoager; Vernizzi, Filippo

    2009-01-01

    We compute the connected four-point correlation function of the primordial curvature perturbation generated during inflation with standard kinetic terms, where the correlation is established via exchange of a graviton between two pairs of scalar fluctuations. Any such correlation yields a contrib...... where the momentum of the graviton which is exchanged becomes much smaller than the external momenta. We conclude that the total non-linearity parameter generated by single-field models of slow-roll inflation is at maximum tauNL ~ r....

  17. Totalization Data Exchange (TDEX)

    Data.gov (United States)

    Social Security Administration — The Totalization Data Exchange (TDEX) process is an exchange between SSA and its foreign country partners to identify deaths of beneficiaries residing abroad. The...

  18. Skew chicane based betatron eigenmode exchange module

    Science.gov (United States)

    Douglas, David

    2010-12-28

    A skewed chicane eigenmode exchange module (SCEEM) that combines in a single beamline segment the separate functionalities of a skew quad eigenmode exchange module and a magnetic chicane. This module allows the exchange of independent betatron eigenmodes, alters electron beam orbit geometry, and provides longitudinal parameter control with dispersion management in a single beamline segment with stable betatron behavior. It thus reduces the spatial requirements for multiple beam dynamic functions, reduces required component counts and thus reduces costs, and allows the use of more compact accelerator configurations than prior art design methods.

  19. 77 FR 61800 - Self-Regulatory Organizations; EDGA Exchange, Inc.; Notice of Filing and Immediate Effectiveness...

    Science.gov (United States)

    2012-10-11

    ... addition, the Exchange also believes that charging Members a lower rate for achieving volume tiers in..., which is consistent with EDGA's low cost exchange model because ROUC offers the Exchange potential cost... offers a discounted rate of $0.0015 per share because the Exchange regards the criteria of each tier as...

  20. Salvage Treatment for Recurrent Intracranial Germinoma After Reduced-Volume Radiotherapy: A Single-Institution Experience and Review of the Literature

    International Nuclear Information System (INIS)

    Hu, Yu-Wen; Huang, Pin-I; Wong, Tai-Tong; Ho, Donald Ming-Tak; Chang, Kai-Ping; Guo, Wan-Yuo; Chang, Feng-Chi; Shiau, Cheng-Yin; Liang, Muh-Lii; Lee, Yi-Yen

    2012-01-01

    Purpose: Intracranial germinomas (IGs) are highly curable with radiotherapy (RT). However, recurrence still occurs, especially when limited-field RT is applied, and the optimal salvage therapy remains controversial. Methods and Materials: Between January 1989 and December 2010, 14 patients with clinically or pathologically diagnosed recurrent IGs after RT were reviewed at our institution. Of these, 11 received focal-field RT, and the other 3 received whole-brain irradiation, whole-ventricle irradiation, and Gamma Knife radiosurgery as the respective first course of RT. In addition, we identified from the literature 88 patients with recurrent IGs after reduced-volume RT, in whom the details of salvage therapy were recorded. Results: The median time to recurrence was 30.3 months (range, 3.8–134.9 months). One patient did not receive further treatment and was lost during follow-up. Of the patients, 7 underwent salvage with craniospinal irradiation (CSI) plus chemotherapy (CT), 4 with CSI alone, 1 with whole-brain irradiation plus CT, and 1 with Gamma Knife radiosurgery. The median follow-up time was 105.1 months (range, 24.2–180.9 months). Three patients died without evidence of disease progression: two from second malignancies and one from unknown cause. The others remained disease free. The 3-year survival rate after recurrence was 83.3%. A total of 102 patients from our study and the literature review were analyzed to determine the factors affecting prognosis and outcomes. After recurrence, the 5-year survival rates were 71% and 92.9% for all patients and for those receiving salvage CSI, respectively. Univariate analysis showed that initial RT volume, initial RT dose, initial CT, and salvage RT type were significant prognostic predictors of survival. On multivariable analysis, salvage CSI was the most significant factor (p = 0.03). Conclusions: Protracted follow-up is recommended because late recurrence is not uncommon. CSI with or without CT is an effective

  1. Exchange market pressure

    NARCIS (Netherlands)

    Jager, H.; Klaassen, F.; Durlauf, S.N.; Blume, L.E.

    2010-01-01

    Currencies can be under severe pressure in the foreign exchange market, but in a fixed (or managed) exchange rate regime that is not fully visible via the change in the exchange rate. Exchange market pressure (EMP) is a concept developed to nevertheless measure the pressure in such cases. This

  2. Comparison of Adjacent Segment Degeneration After Nonrigid Fixation System and Posterior Lumbar Interbody Fusion for Single-Level Lumbar Disc Herniation: A New Method of MRI Analysis of Lumbar Nucleus Pulposus Volume.

    Science.gov (United States)

    Yang, Shaofeng; Liu, Yanan; Bao, Zhaohua; Zou, Jun; Yang, Huilin

    2017-05-19

    To evaluate the influence of a nonrigid fixation system and posterior lumbar interbody fusion on adjacent intervertebral disc degeneration by using MRI analysis of lumbar nucleus pulposus volume for single-level lumbar disc herniation. We selected 112 patients who underwent nonrigid fixation (17 men and 44 women) or posterior lumbar interbody fusion (13 men and 38 women) for this retrospective study. Based on the T2-weighted magnetic resonance imaging (MRI) scans taken preoperatively, and 6, 12, and 24 months after surgery, the nucleus pulposus in the upper segments of the operated level was considered an ellipsoid, and their volumes were measured respectively and then compared between the two groups. The posterior lumbar interbody fusion group had significantly lower lumbar nucleus pulposus volume than the nonrigid fixation group at 12 (4.04 ± 1.42 vs. 5.25 ± 1.47 mm 3 ) and 24 months (4.16 ± 0.89 vs. 5.06 ± 1.23 mm 3 ), and had the highest nucleus pulposus. Meanwhile, the h value in the posterior lumbar interbody fusion group was notably smaller than the preoperative level at 12 (0.46 ± 0.03 vs. 0.55 ± 0.05 mm) and 24 months (0.44 ± 0.03 vs. 0.55 ± 0.05 mm). MRI analysis of lumbar nucleus pulposus volume is a new and quantitative method of analysis, which is a considerable method and contributes to the detection of severe intervertebral disc degeneration. Based on this new method, nonrigid fixation demonstrates excellent outcomes on the adjacent segment in comparison with posterior lumbar interbody fusion.

  3. The volume of a soliton

    Directory of Open Access Journals (Sweden)

    C. Adam

    2016-03-01

    Full Text Available There exists, in general, no unique definition of the size (volume, area, etc., depending on dimension of a soliton. Here we demonstrate that the geometric volume (area etc. of a soliton is singled out in the sense that it exactly coincides with the thermodynamical or continuum-mechanical volume. In addition, this volume may be defined uniquely for rather arbitrary solitons in arbitrary dimensions.

  4. Comparison of stroke volume and cardiac output as measured by a single observer using four different ultrasound techniques in six clinically healthy cats.

    Science.gov (United States)

    Biermann, K; Hungerbühler, S; Kästner, S B R

    2012-12-01

    The aim of this study was to assess agreement and repeatability of four ultrasound methods for measuring stroke volume (SV) and cardiac output (CO) in cats. Measurement of SV and CO was performed by the Teichholz method, the Simpson's method (SM), the area length method (ALM) and a volumetric flow method across the aorta (Trace method). For each method, the coefficient of variation (CV) was calculated and agreement was determined by Bland-Altman analysis. The CV was acceptable (parameters, except for SV and CO obtained by SM (28.8% and 22.4%, respectively) and ALM (21.6% and 22.6%, respectively). Narrow limits of agreement were observed between both planimetric methods (SM and ALM). The Trace method was the most repeatable, followed by the Teichholz method. Despite excellent inter-method agreement, neither of the planimetric methods produced results with adequate repeatability. As the Teichholz and Trace methods were acceptably repeatable, and probably gave the most representative values, they appear to be the most useful methods for the measurement of SV and CO in cats. Further investigations are needed to compare the echocardiographic methods described here with a standard technique such as thermodilution. Copyright © 2012. Published by Elsevier Ltd.

  5. Development in Waste Volume Reduction Technologies for Highly Contaminated Organic Radioactive Compounds

    International Nuclear Information System (INIS)

    AKAI, Yoshie; OHMURA, Hisao; FUJIE, Makoto; MONIWA, Shinobu; SEKI, Shuji; YOTSUYANAGI, Tadasu; EBATA, Masaaki; TAKAGI, Junichi

    2006-01-01

    In nuclear facilities, there is highly contaminated organic radioactive waste such as ion exchange resins for water purification in nuclear power plants. In the future, it is desired that this waste be decomposed to reduce the volume and to become stable. Toshiba has developed a waste treatment system using supercritical water. Furthermore, the new demineralization system without using ion exchange resin has been examined. By this new system, it is possible to reduce the volume of ion exchange resin waste. First, supercritical water was applied to the decomposition of ion exchange resin. The supercritical water whose temperature and pressure exceed 647 K and 22 MPa is an excellent solvent for organic compound decomposition, since oxygen and organic compounds can exist in a single homogeneous fluid phase. Organic compounds can be rapidly and completely decomposed using supercritical water. Almost all the reactants can be kept in the water during organic compound decomposition. Therefore, applying supercritical water to treat organic radioactive waste is an attractive proposition. Actual plant-size apparatus was constructed with a treatment capacity of 1 kg of ion exchange resin per hour. The test revealed that more than 99.9% of the ion exchange resin was decomposed at 723 K and 30 MPa. By this system, ion exchange resin decomposes rapidly and completely, and the volume of ion exchange resin waste can be largely reduced. Secondly, the new demineralization system without using ion exchange resin is described. The new demineralization system consists of a filter and a demineralization cell. A metal mesh filter is adopted to remove crud, and the demineralization cell removes ionic impurities. In this system, it is important whether demineralization can take place at high temperature. Thus, this report describes the test results of the new demineralization process. This demineralization cell consists of an anode, a cathode, and a membrane made of inorganic material. The

  6. Evaluation of matrices for immobilizing ion-exchange resins

    International Nuclear Information System (INIS)

    Buckley, L.P.; Speranzini, R.A.

    1980-07-01

    Ion exchange resins make up a significant fraction of the volume of radioactive wastes generated during the operation of CANDU-PHW nuclear power stations. Since permanent disposal will eventually be required for these contaminated ion-exchange resins, some way to reduce their volume and to immobilize their radionuclides is required. An evaluation of the processes for immobilizing contaminated ion exchange resins directly into glasses, plastics, bitumens and cements is reported here. Releases of Cs-137, Co-60 and C-14 in leach testss were found to be lowest for bitumen followed by glasses, plastics and cements. Approximately 8% of the C-14 inventory on the ion-exchange resins is released into the off-gas system during glass formation and could limit use of this option. A pyrolysis method for a three-fold reduction in the volume of used ion-exchange resins is described. (auth)

  7. COMMIX-1AR/P: A three-dimensional transient single-phase computer program for thermal hydraulic analysis of single and multicomponent systems. Volume 2, User`s guide

    Energy Technology Data Exchange (ETDEWEB)

    Garner, P.L.; Blomquist, R.N.; Gelbard, E.M.

    1992-09-01

    The COMMIX-1AR/P computer program is designed for analyzing the steady-state and transient aspects of single-phase fluid flow and heat transfer in three spatial dimensions. This version is an extension of the modeling in COMMIX-1A to include multiple fluids in physically separate regions of the computational domain, modeling descriptions for pumps, radiation heat transfer between surfaces of the solids which are embedded in or surround the fluid, a k-{var_epsilon} model for fluid turbulence, and improved numerical techniques. The porous-medium formulation in COMMIX allows the program to be applied to a wide range of problems involving both simple and complex geometrical arrangements. The input preparation and execution procedures are presented for the COMMIX-1AR/P program and several postprocessor programs which produce graphical displays of the calculated results.

  8. The use of purse-string skin closure in loop ileostomy reversals leads to lower wound infection rates--a single high-volume centre experience.

    Science.gov (United States)

    Habbe, Nils; Hannes, Sabine; Liese, Juliane; Woeste, Guido; Bechstein, Wolf Otto; Strey, Christoph

    2014-06-01

    Wound infections affect not only the individual patient but lead to an increase in medical costs. After ileostomy reversal, surgical site infections are a common problem. The objective of the study was to compare the infection rates of purse-string and conventional skin closure techniques in a high volume setting. Patients undergoing ileostomy reversal at the Goethe University Hospital between January 2009 and August 2012 were retrospectively analysed regarding surgical site infections and associated risk factors. Patients received either conventional skin closure (running, interrupted or stapled suturing; group C) or subcuticular purse-string suture (group PS). In total, 114 patients have been analysed. Conventional wound closure was performed in 81 patients and 33 patients received purse-string skin closure. The groups did not differ regarding age, gender, indication for ileostomy, previous chemotherapy, and operation time. Median hospital stay was 7 days (3-34) in group PS and 8 (3-53) in group C (p = 0.15). Wound infections only occurred in groups C (n = 10, 12 %) compared to group PS (n = 0; 0 %; p = 0.034), and the wound closure technique was the only significant factor associated with surgical site infection. Surgery performed by a resident under supervision was not a risk factor for complications compared to the procedure done by a senior surgeon (p = 0.73). This study reveals an advantage of the purse-string skin closure technique in ileostomy reversals analysing a large cohort of patients. Therefore, we recommend the use of the purse-string skin closure in ileostomy reversals as one way to lower wound infection rates.

  9. Single-Molecule Spectroscopy

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 20; Issue 2. Single-Molecule Spectroscopy: Every Molecule is Different! Kankan Bhattacharyya. General Article Volume 20 Issue 2 February 2015 pp 151-164. Fulltext. Click here to view fulltext PDF. Permanent link:

  10. Automated (Centrifugal) Therapeutic Plasma Exchange Option for ...

    African Journals Online (AJOL)

    However, he had intact sensory perceptions to touch and pain. Following a diagnosis of GBS, he was treated with four sessions of plasmapheresis and TPE. The TPE session was done using a discontinuous flow apheresis machine which exchanged one plasma volume (3 L of plasma) and 5% albumin used for ...

  11. Is Erythrocyte Protoporphyrin a Better Single Screening Test for Iron Deficiency Compared to Hemoglobin or Mean Cell Volume in Children and Women?

    Directory of Open Access Journals (Sweden)

    Zuguo Mei

    2017-05-01

    Full Text Available Hemoglobin (Hb, mean cell volume (MCV, and erythrocyte protoporphyrin (EP are commonly used to screen for iron deficiency (ID, but systematic evaluation of the sensitivity and specificity of these tests is limited. The objective of this study is to determine the sensitivity and specificity of Hb, MCV, and EP measurements in screening for ID in preschool children, non-pregnant women 15–49 years of age, and pregnant women. Data from the National Health and Nutrition Examination Surveys (NHANES (NHANES 2003–2006: n = 861, children three to five years of age; n = 3112, non-pregnant women 15 to 49 years of age. NHANES 1999–2006: n = 1150, pregnant women were examined for this purpose. Children or women with blood lead ≥10 µg/dL or C-reactive protein (CRP >5.0 mg/L were excluded. ID was defined as total body iron stores <0 mg/kg body weight, calculated from the ratio of soluble transferrin receptor (sTfR to serum ferritin (SF. The receiver operating characteristic (ROC curve was used to characterize the sensitivity and specificity of Hb, MCV, and EP measurements in screening for ID. In detecting ID in children three to five years of age, EP (Area under the Curve (AUC 0.80 was superior to Hb (AUC 0.62 (p < 0.01 but not statistically different from MCV (AUC 0.73. In women, EP and Hb were comparable (non-pregnant AUC 0.86 and 0.84, respectively; pregnant 0.77 and 0.74, respectively, and both were better than MCV (non-pregnant AUC 0.80; pregnant 0.70 (p < 0.01. We concluded that the sensitivity and specificity of EP in screening for ID were consistently superior to or at least as effective as those of Hb and MCV in each population examined. For children three to five years of age, EP screening for ID was significantly better than Hb and similar to MCV. For both non-pregnant and pregnant women, the performance of EP and Hb were comparable; both were significantly superior to MCV.

  12. Heat Exchanger Design Options and Tritium Transport Study for the VHTR System

    Energy Technology Data Exchange (ETDEWEB)

    Chang H. Oh; Eung S. Kim

    2008-09-01

    This report presents the results of a study conducted to consider heat exchanger options and tritium transport in a very high temperature reactor (VHTR) system for the Next Generation Nuclear Plant Project. The heat exchanger options include types, arrangements, channel patterns in printed circuit heat exchangers (PCHE), coolant flow direction, and pipe configuration in shell-and-tube designs. Study considerations include: three types of heat exchanger designs (PCHE, shell-and-tube, and helical coil); single- and two-stage unit arrangements; counter-current and cross flow configurations; and straight pipes and U-tube designs in shell-and-tube type heat exchangers. Thermal designs and simple stress analyses were performed to estimate the heat exchanger options, and the Finite Element Method was applied for more detailed calculations, especially for PCHE designs. Results of the options study show that the PCHE design has the smallest volume and heat transfer area, resulting in the least tritium permeation and greatest cost savings. It is theoretically the most reliable mechanically, leading to a longer lifetime. The two-stage heat exchanger arrangement appears to be safer and more cost effective. The recommended separation temperature between first and second stages in a serial configuration is 800oC, at which the high temperature unit is about one-half the size of the total heat exchanger core volume. Based on simplified stress analyses, the high temperature unit will need to be replaced two or three times during the plant’s lifetime. Stress analysis results recommend the off-set channel pattern configuration for the PCHE because stress reduction was estimated at up to 50% in this configuration, resulting in a longer lifetime. The tritium transport study resulted in the development of a tritium behavior analysis code using the MATLAB Simulink code. In parallel, the THYTAN code, previously performed by Ohashi and Sherman (2007) on the Peach Bottom data, was revived

  13. Characteristics of resin floc dispersion of anion and cation exchange resin in precoat filter using powdered ion exchange resin

    Energy Technology Data Exchange (ETDEWEB)

    Adachi, Tetsurou (Nitto Denko Corp., Ibaraki, Osaka (Japan)); Sawa, Toshio; Shindoh, Toshikazu

    1989-09-01

    The filtration performance of mixed filter aid consisting of powdered anion and cation exchange resins used in the precoat filter is closely related to the characteristics of resin floc dispersion. The factors related to resin floc dispersion of anion and cation exchange resin were investigated by measuring the specific settle volume of resin floc as an evaluating index in addition to the measurement of physical, chemical and electrochemical properties of powdered ion exchange resin. The effect of adsorption of iron oxide and polymer electrolyte and of ion exchange were determined. In addition, considered floc dispersion with adsorbing iron oxide, it was assumed that the amount and filling ratio of resin floc were related to summation and multiplication of surface electric charge respectively. An experimental expression was obtained for simulation of the change of specific settle volume of resin floc by particle size, surface area, ion exchange capacity and degree of ionization of the powdered ion exchange resin. (author).

  14. Characteristics of resin floc dispersion of anion and cation exchange resin in precoat filter using powdered ion exchange resin

    International Nuclear Information System (INIS)

    Adachi, Tetsurou; Sawa, Toshio; Shindoh, Toshikazu.

    1989-01-01

    The filtration performance of mixed filter aid consisting of powdered anion and cation exchange resins used in the precoat filter is closely related to the characteristics of resin floc dispersion. The factors related to resin floc dispersion of anion and cation exchange resin were investigated by measuring the specific settle volume of resin floc as an evaluating index in addition to the measurement of physical, chemical and electrochemical properties of powdered ion exchange resin. The effect of adsorption of iron oxide and polymer electrolyte and of ion exchange were determined. In addition, considered floc dispersion with adsorbing iron oxide, it was assumed that the amount and filling ratio of resin floc were related to summation and multiplication of surface electric charge respectively. An experimental expression was obtained for simulation of the change of specific settle volume of resin floc by particle size, surface area, ion exchange capacity and degree of ionization of the powdered ion exchange resin. (author)

  15. Hyporheic exchange in mountain rivers I: Mechanics and environmental effects

    Science.gov (United States)

    Daniele Tonina; John M. Buffington

    2009-01-01

    Hyporheic exchange is the mixing of surface and shallow subsurface water through porous sediment surrounding a river and is driven by spatial and temporal variations in channel characteristics (streambed pressure, bed mobility, alluvial volume and hydraulic conductivity). The significance of hyporheic exchange in linking fluvial geomorphology, groundwater, and riverine...

  16. Assessment of the exchange parameters of Amberlite IR-45 (OH ...

    African Journals Online (AJOL)

    Simple quantitative technique has been developed for assessing the exchange parameters of Amberlite IR – 45 (OH) using column chromatographic techniques from the displacement of exchangeable hydroxyl ions of the resin by sulphate ions. The results obtained showed retention time of 33min, retention volume of ...

  17. Data Exchange over Web-based Applications with DXL

    NARCIS (Netherlands)

    van Zwol, Roelof; Fokkinga, M.M.; Jeronimus, V.; Jeronimus, V.N.; Apers, Peter M.G.; Lacroix, Z.

    2002-01-01

    With large volumes of data being exchanged on the Internet, query languages are needed to bridge the gap between databases and the web. Furthermore, the differentiation in data types used by webbased applications is ever growing, despite all standardization efforts. The Data eXchange Language (DXL)

  18. Energy Conversion Alternatives Study (ECAS), Westinghouse phase 1. Volume 2: Materials considerations. [materials used in boilers and heat exchangers of energy conversion systems for electric power plants using coal

    Science.gov (United States)

    Thomas, D. E.

    1976-01-01

    Extensive studies are presented which were carried out on materials behavior in nine advanced energy conversion systems employing coal and coal-derived fuels. The areas of materials behavior receiving particular attention in this regard are: (1) fireside corrosion and erosion in boiler and heat exchanger materials, (2) oxidation and hot corrosion of gas turbine materials, (3) liquid metal corrosion and mass transport, (4) high temperature steam corrosion, (5) compatability of materials with coal slag and MHD seed, (6) reaction of materials with impure helium, (7) allowable stresses for boiler and heat exchanger materials, (8) environmental effects on mechanical properties, and (9) liquid metal purity control and instrumentation. Such information was then utilized in recommending materials for use in the critical components of the power systems, and at the same time to identify materials problem areas and to evaluate qualitatively the difficulty of solving those problems. Specific materials recommendations for critical components of the nine advanced systems under study are contained in summary tables.

  19. Charge exchange, surface-induced dissociation and reactions of doubly charged molecular ions SF42+ upon impact on a stainless steel surface: A comparison with surface-induced dissociation of singly charged SF4+ molecular ions

    Czech Academy of Sciences Publication Activity Database

    Feketeová, L.; Grill, V.; Zappa, F.; Endstrasser, N.; Rasul, B.; Herman, Zdeněk; Scheier, P.; Märk, T. D.

    2008-01-01

    Roč. 276, č. 1 (2008), s. 37-42 ISSN 1387-3806 Institutional research plan: CEZ:AV0Z40400503 Keywords : doubly charged ion * surface-induced dissociations * surface-induced reaction * charge exchange Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 2.445, year: 2008

  20. Compact Ceramic Microchannel Heat Exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Lewinsohn, Charles [Ceramatec, Inc., Salt Lake City, UT (United States)

    2016-10-31

    The objective of the proposed work was to demonstrate the feasibility of a step change in power plant efficiency at a commercially viable cost, by obtaining performance data for prototype, compact, ceramic microchannel heat exchangers. By performing the tasks described in the initial proposal, all of the milestones were met. The work performed will advance the technology from Technology Readiness Level 3 (TRL 3) to Technology Readiness Level 4 (TRL 4) and validate the potential of using these heat exchangers for enabling high efficiency solid oxide fuel cell (SOFC) or high-temperature turbine-based power plants. The attached report will describe how this objective was met. In collaboration with The Colorado School of Mines (CSM), specifications were developed for a high temperature heat exchanger for three commercial microturbines. Microturbines were selected because they are a more mature commercial technology than SOFC, they are a low-volume and high-value target for market entry of high-temperature heat exchangers, and they are essentially scaled-down versions of turbines used in utility-scale power plants. Using these specifications, microchannel dimensions were selected to meet the performance requirements. Ceramic plates were fabricated with microchannels of these dimensions. The plates were tested at room temperature and elevated temperature. Plates were joined together to make modular, heat exchanger stacks that were tested at a variety of temperatures and flow rates. Although gas flow rates equivalent to those in microturbines could not be achieved in the laboratory environment, the results showed expected efficiencies, robust operation under significant temperature gradients at high temperature, and the ability to cycle the stacks. Details of the methods and results are presented in this final report.

  1. Laser Processed Heat Exchangers

    Data.gov (United States)

    National Aeronautics and Space Administration — The considerable mass of Heat Exchangers (HXs) and coldplates on spacecraft as well as the problematic coatings of the Condensing Heat Exchanger (CHX) are among the...

  2. Isotopically exchangeable phosphorus

    International Nuclear Information System (INIS)

    Barbaro, N.O.

    1984-01-01

    A critique revision of isotope dilution is presented. The concepts and use of exchangeable phosphorus, the phosphate adsorption, the kinetics of isotopic exchange and the equilibrium time in soils are discussed. (M.A.C.) [pt

  3. 78 FR 51251 - Self-Regulatory Organizations; New York Stock Exchange LLC; Notice of Filing and Immediate...

    Science.gov (United States)

    2013-08-20

    ... orders, and higher volumes of MOC and LOC orders will contribute to the quality of the Exchange's closing.... The Exchange believes that the proposed d-Quote rate of $0.0010 per share for Floor brokers executing... believe that Floor brokers that are removing higher volumes of liquidity via d- Quotes from the Exchange...

  4. Phase Space Exchange in Thick Wedge Absorbers

    Energy Technology Data Exchange (ETDEWEB)

    Neuffer, David [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2017-01-01

    The problem of phase space exchange in wedge absorbers with ionization cooling is discussed. The wedge absorber exchanges transverse and longitudinal phase space by introducing a position-dependent energy loss. In this paper we note that the wedges used with ionization cooling are relatively thick, so that single wedges cause relatively large changes in beam phase space. Calculation methods adapted to such “thick wedge” cases are presented, and beam phase-space transformations through such wedges are discussed.

  5. 78 FR 62728 - Self Regulatory Organizations; Chicago Stock Exchange, Inc.; Notice of Filing and Immediate...

    Science.gov (United States)

    2013-10-22

    .... i. Exchange Membership Overview Exchange Participants are considered ``members'' of the Exchange for... address any other issues surrounding regulatory fees and that the Exchange is not aware of any problems... submitting a single form, fingerprint card and a combined payment of fees to FINRA. Through the CRD system...

  6. 78 FR 6373 - Self-Regulatory Organizations; EDGX Exchange, Inc.; Notice of Filing and Immediate Effectiveness...

    Science.gov (United States)

    2013-01-30

    ... Exchange differentiates its pricing accordingly. The Exchange intends to charge a single, flat rate for... hone in on trading opportunities by better understanding the quality and transparency of the Exchange's... related to the value of an exchange's market quality associated with higher levels of market activity...

  7. Developing an exchange mindset.

    Science.gov (United States)

    Thackeray, Rosemary

    2010-09-01

    Exchange is a fundamental concept that underlies all social marketing efforts. In a successful exchange, both parties receive something of value and the benefits that they desire in return for a price. The purpose of this article is to describe how practitioners can develop an "exchange mindset." A practitioner's answer to five basic questions will enable him or her to see the exchange through the eyes of the customer and increase the likelihood of creating a successful exchange that will benefit both parties involved and result in positive behavior change.

  8. Communication network exchange

    International Nuclear Information System (INIS)

    Woo, Seung Sul

    1988-05-01

    This book has two parts. The first parts is comprised of five chapters, which deals with communication network constitution with design of network and types, telephone network about outline and management of network, telephone network · data network · private network, international data telephone network about service and international data network and technical standards of quality of service, communication and data. The second parts handles exchange, which is about institution of switching, a manual exchange and step-by step exchange, a crossbar exchange, electronic exchange, international switching system, design of equipment of test and measurement.

  9. Mark-18A Ion Exchange Raffinate Management Strategy & Processing Recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Smith, T. E. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Nash, C. A. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-06-21

    It is desired to recover Cm-244 through Cm-248 from dissolved Mark-18A targets following anion exchange processing to remove the Pu. The Cm will be sent to Oak Ridge National Laboratory (ORNL) for additional R&D. Approximately 5-8 L per quarter of a Mark-18A target will have undergone anion exchange treatment and will contain Cm. A significant portion of this volume of anion exchange raffinate solution is dissolved fission products not desired to be recovered which could be sent to waste. To reduce the amount of material being sent to ORNL, a waste and volume minimization strategy was developed and is described in this report.

  10. DIVALENT ION EXCHANGE WITH ALKALI

    Energy Technology Data Exchange (ETDEWEB)

    Bunge, A.L.; Klein, G.; Radke, C.J.

    1980-05-01

    Exchange of hardness ions is important in enhanced oil recovery with chemical additives. In both micellar-polymer and caustic flooding processes, multivalent ions released from rock surfaces can interact with anionic surfactants, rendering them preferentially oil soluble and/or insoluble in water. Because hardness cations are sparingly soluble and precipitate in alkaline solutions, such solutions may be more efficient as surfactant flood preflushes than are softened brines. Multivalent ion precipitation may also occur in alkaline waterflooding. To permit design of such processes, this paper presents a chromatographic theory for simultaneous ion exchange with precipitation of divalent ions. Theoretical effluent histories and concentration profiles are presented for the cases of finite pulses and continuous injection of hydroxide ions into linear cores. Complete capture of the insoluble salt particles is assumed. Results are given for the case of instantaneous equilibration of the solution with the precipitate, as well for the case of complete nonequilibrium, in which the solid precipitate does not redissolve. The efficiency of alklaine preflushing is shown to depend on the exchange isotherm, initial divalent loading of the rock, injected pH and salinity, the solubility product of the precipitated salt, and pulse size. The effect of slug size on complete equilibrium removal of hardness ions is reduced efficiency with increasing size until a critical volume approximating continuous injection is reached. Increasing injected pH and salinity provides a more favorable response. Experimental data for Berea sandstone and an argillaceous sand compare favorably with the proposed theory.

  11. ABC's of pion charge exchange

    International Nuclear Information System (INIS)

    Gibbs, W.R.; Kaufmann, W.B.; Siegel, P.B.

    1985-01-01

    Calculations of pion single charge exchange using the PWIA and DWIA are presented. Emphasis is given to the effects of absorbtion and blocking. A microscopic calculation of the 0 0 excitation and low energy angular distribution is in excellent agreement with the data. A fixed nucleon multiple scattering calculation of the pion double charge exchange reaction is presented. Various valence neutron wave functions are used, and the contributions of different spatial orientations of the last two neutrons to the reaction are examined. The DCX cross section is found to be very sensitive to the inclusion of correlations in the two-neutron wave function. Satisfactory agreement with DCX data on 14 C can be obtained using a nucleonic picture of the nucleus

  12. Steel reinforced composite silicone membranes and its integration to microfluidic oxygenators for high performance gas exchange.

    Science.gov (United States)

    Matharoo, Harpreet; Dabaghi, Mohammadhossein; Rochow, Niels; Fusch, Gerhard; Saraei, Neda; Tauhiduzzaman, Mohammed; Veldhuis, Stephen; Brash, John; Fusch, Christoph; Selvaganapathy, P Ravi

    2018-01-01

    Respiratory distress syndrome (RDS) is one of the main causes of fatality in newborn infants, particularly in neonates with low birth-weight. Commercial extracorporeal oxygenators have been used for low-birth-weight neonates in neonatal intensive care units. However, these oxygenators require high blood volumes to prime. In the last decade, microfluidics oxygenators using enriched oxygen have been developed for this purpose. Some of these oxygenators use thin polydimethylsiloxane (PDMS) membranes to facilitate gas exchange between the blood flowing in the microchannels and the ambient air outside. However, PDMS is elastic and the thin membranes exhibit significant deformation and delamination under pressure which alters the architecture of the devices causing poor oxygenation or device failure. Therefore, an alternate membrane with high stability, low deformation under pressure, and high gas exchange was desired. In this paper, we present a novel composite membrane consisting of an ultra-thin stainless-steel mesh embedded in PDMS, designed specifically for a microfluidic single oxygenator unit (SOU). In comparison to homogeneous PDMS membranes, this composite membrane demonstrated high stability, low deformation under pressure, and high gas exchange. In addition, a new design for oxygenator with sloping profile and tapered inlet configuration has been introduced to achieve the same gas exchange at lower pressure drops. SOUs were tested by bovine blood to evaluate gas exchange properties. Among all tested SOUs, the flat design SOU with composite membrane has the highest oxygen exchange of 40.32 ml/min m 2 . The superior performance of the new device with composite membrane was demonstrated by constructing a lung assist device (LAD) with a low priming volume of 10 ml. The LAD was achieved by the oxygen uptake of 0.48-0.90 ml/min and the CO 2 release of 1.05-2.27 ml/min at blood flow rates ranging between 8 and 48 ml/min. This LAD was shown to increase the

  13. Modeling and off-design performance of a 1 kWe HT-PEMFC (high temperature-proton exchange membrane fuel cell)-based residential micro-CHP (combined-heat-and-power) system for Danish single-family households

    DEFF Research Database (Denmark)

    Arsalis, Alexandros; Nielsen, Mads Pagh; Kær, Søren Knudsen

    2011-01-01

    temperatures, as compared to Nafion-based PEMFCs and therefore can be a significant candidate for cogeneration residential systems. The proposed system can provide electric power, hot water, and space heating for a typical Danish single-family household. A complete fuel processing subsystem, with all necessary......A novel proposal for the modeling and operation of a micro-CHP (combined-heat-and-power) residential system based on HT-PEMFC (High Temperature-Proton Exchange Membrane Fuel Cell) technology is described and analyzed to investigate its commercialization prospects. An HT-PEMFC operates at elevated...

  14. Automated exchange transfusion and exchange rate.

    Science.gov (United States)

    Funato, M; Shimada, S; Tamai, H; Taki, H; Yoshioka, Y

    1989-10-01

    An automated blood exchange transfusion (BET) with a two-site technique has been devised by Goldmann et al and by us, using an infusion pump. With this method, we successfully performed exchange transfusions 189 times in the past four years on 110 infants with birth weights ranging from 530 g to 4,000 g. The exchange rate by the automated method was compared with the rate by Diamond's method. Serum bilirubin (SB) levels before and after BET and the maximal SB rebound within 24 hours after BET were: 21.6 +/- 2.4, 11.5 +/- 2.2, and 15.0 +/- 1.5 mg/dl in the automated method, and 22.0 +/- 2.9, 11.2 +/- 2.5, and 17.7 +/- 3.2 mg/dl in Diamond's method, respectively. The result showed that the maximal rebound of the SB level within 24 hours after BET was significantly lower in the automated method than in Diamond's method (p less than 0.01), though SB levels before and after BET were not significantly different between the two methods. The exchange rate was also measured by means of staining the fetal red cells (F cells) both in the automated method and in Diamond's method, and comparing them. The exchange rate of F cells in Diamond's method went down along the theoretical exchange curve proposed by Diamond, while the rate in the automated method was significantly better than in Diamond's, especially in the early stage of BET (p less than 0.01). We believe that the use of this automated method may give better results than Diamond's method in the rate of exchange, because this method is performed with a two-site technique using a peripheral artery and vein.

  15. A segmentectomy of the right upper lobe has an advantage over a right upper lobectomy regarding the preservation of the functional volume of the right middle lobe. Analysis by perfusion single-photon emission computed tomography/computed tomography

    International Nuclear Information System (INIS)

    Yoshimoto, Kentaro; Nomori, Hiroaki; Mori, Takeshi; Ohba, Yasuomi; Shibata, Hidekatsu; Tashiro, Kuniyuki; Shiraishi, Shinya; Kobayashi, Toshiaki

    2010-01-01

    To evaluate the advantages of a segmentectomy of the right upper lobe (RUL) over a right upper (RU) lobectomy regarding the preservation of the functional volume of the right middle lobe (RML), the postoperative forced expiratory volume in one second (FEV 1 ) of the RML was compared between an RU lobectomy and an RUL segmentectomy, by using a coregistered perfusion single-photon emission computed tomography and computed tomography (SPECT/CT). The pulmonary function tests and perfusion SPECT/CT were conducted before and after surgery (RU lobectomy: 7; RUL segmentectomy: 13). The FEV 1 of the RML before and after surgery was calculated from the data of the pulmonary function test and SPECT/CT. In the RU lobectomy group, the percentage change of FEV 1 was 71%±12%, which was significantly lower in comparison to 92%±9% in the RUL segmentectomy group (P=0.001). In the lobectomy group, the preoperative FEV 1 of the RML was 0.17±0.101 which decreased significantly to 0.06±0.061 after surgery (P=0.009). In the segmentectomy group, FEV 1 of the RML before and after the surgery were 0.23±0.101 and 0.20±0.111, of which the difference was not significant. An RUL segmentectomy has an advantage over an RU lobectomy regarding the preservation of pulmonary function, due to a greater preservation of not only the lung tissue, but also the FEV 1 of the RML. (author)

  16. Volume reduction by oxidation

    International Nuclear Information System (INIS)

    Kuribayashi, H.; Hasegawa, A.; Koshiba, Y.; Yamanaka, A.

    1984-01-01

    JGC Corporation has been actively investigating the treatment of various combustible and organic wastes generated at nuclear power stations and reprocessing plants. In particular, JGC has analyzed three new technologies which produce dramatic volume reductions and complete conversion of wastes into inorganic substances for durable storage and disposal. Those technologies are; Incineration, Wet oxidation and Photooxidation. Incineration is an excellent volume reducer for combustible wastes, and wet oxidation, using hydrogen peroxide, is also a good way for reducing spent ion-exchange resins without any off-gas problems. Photooxidation is a new technology to purify polluted water for recycled use in the stations without th release of contaminated water to the environment. Polluted water may include NH4+, detergents, chelating agents and other organic decontamination agents. These VR technologies are all based on ''Oxidation'' from which the title of this paper comes

  17. Performance Evaluation of Plate - Fin Heat Exchangers.

    Science.gov (United States)

    1987-06-01

    children for their support, patience, understanding, and love during the preparation of this thesis and for the period of study at M.I.T. I’ .1’ -p...the ordinate values will yiela the number of heat transfer units ratio of the two heat exchangers. The required ratios are: Ren,b AFo On,b Reno AFb Dn...Dn a = Dno) tne frontal area for surface 2 will be greater than surface 1, AF .d > AFo . The same heat exchanger volume implies that the length wii

  18. Navvus FFR to reduce CONTRAst, Cost and radiaTion (CONTRACT); insights from a single-centre clinical and economical evaluation with the RXi Rapid-Exchange FFR device

    NARCIS (Netherlands)

    Masdjedi, K.; Mieghem, N.M. van; Diletti, R.; Geuns, R.J.M. van; Jaegere, P. De; Regar, E.; Zijlstra, F.; Domburg, R.T. van; Daemen, J.

    2017-01-01

    OBJECTIVES: To assess whether the RXi Navvus system compared to the use of standard Fractional Flow Reserve (FFR) wires reduces total contrast volume, radiation and overall study cost in a real world patient population referred for coronary angiography or percutaneous coronary intervention.

  19. 78 FR 1907 - Self-Regulatory Organizations; BOX Options Exchange LLC; Notice of Filing and Immediate...

    Science.gov (United States)

    2013-01-09

    ... than passing the costs of these higher order volumes along to all market participants, the Exchange... manner. Generally, competing options exchanges assess Professionals fees at comparable rates to those... through better executions on BOX, a monthly average of more than $3.5 million over that time. The Exchange...

  20. Microsoft Exchange 2013 cookbook

    CERN Document Server

    Van Horenbeeck, Michael

    2013-01-01

    This book is a practical, hands-on guide that provides the reader with a number of clear, step-by-step exercises.""Microsoft Exchange 2013 Cookbook"" is targeted at network administrators who deal with the Exchange server in their day-to-day jobs. It assumes you have some practical experience with previous versions of Exchange (although this is not a requirement), without being a subject matter expert.

  1. Protein-stimulated exchange of phosphatidylcholine between intact erythrocytes and various membrane systems

    NARCIS (Netherlands)

    Meer, G. van; Lange, L.G.; Kamp, J.A.F. op den; Deenen, L.L.M. van

    1980-01-01

    Phosphatidylcholine specific exchange protein from beef liver was found to catalyze the exchange of phosphatidylcholine between intact rat and human erythrocytes and various artificial membranes. Both multilamellar liposomes and single bilayer vesicles prepared from egg lecithin, cholesterol and

  2. Biodegradation of ion-exchange media

    International Nuclear Information System (INIS)

    Bowerman, B.S.; Clinton, J.H.; Cowdery, S.R.

    1988-08-01

    Ion-exchange media, both bead resins and powdered filter media, are used in nuclear power plants to remove radioactivity from process water prior to reuse or environmental discharge. Since the ion- exchange media are made from synthetic hydrocarbon-based polymers, they may be susceptible to damage from biological activity. The purpose of this study was to investigate some of the more basic aspects of biodegradation of ion-exchange media, specifically to evaluate the ability of microorganisms to utilize the ion-exchange media or materials sorbed on them as a food source. The ASTM-G22 test, alone and combined with the Bartha Pramer respirometric method, failed to indicate the biodegradability of the ion-exchange media. The limitation of these methods was that they used a single test organism. In later phases of this study, a mixed microbial culture was grown from resin waste samples obtained from the BNL High Flux Beam Reactor. These microorganisms were used to evaluate the susceptibility of different types of ion-exchange media to biological attack. Qualitative assessments of biodegradability were based on visual observations of culture growths. Greater susceptibility was associated with increased turbidity in solution indicative of bacterial growth, and more luxuriant fungal mycelial growth in solution or directly on the ion-exchange resin beads. 21 refs., 9 figs., 18 tabs

  3. Multiprocessor shared-memory information exchange

    International Nuclear Information System (INIS)

    Santoline, L.L.; Bowers, M.D.; Crew, A.W.; Roslund, C.J.; Ghrist, W.D. III

    1989-01-01

    In distributed microprocessor-based instrumentation and control systems, the inter-and intra-subsystem communication requirements ultimately form the basis for the overall system architecture. This paper describes a software protocol which addresses the intra-subsystem communications problem. Specifically the protocol allows for multiple processors to exchange information via a shared-memory interface. The authors primary goal is to provide a reliable means for information to be exchanged between central application processor boards (masters) and dedicated function processor boards (slaves) in a single computer chassis. The resultant Multiprocessor Shared-Memory Information Exchange (MSMIE) protocol, a standard master-slave shared-memory interface suitable for use in nuclear safety systems, is designed to pass unidirectional buffers of information between the processors while providing a minimum, deterministic cycle time for this data exchange

  4. A remark on the infinite-volume Gibbs measures of spin glasses

    Science.gov (United States)

    Arguin, Louis-Pierre

    2008-12-01

    In this note, we point out that infinite-volume Gibbs measures of spin glass models on the hypercube can be identified as random probability measures on the unit ball of a Hilbert space. This simple observation follows from a result of Dovbysh and Sudakov on weakly exchangeable random matrices. Limiting Gibbs measures can then be studied as single well-defined objects. This approach naturally extends the space of random overlap structures as defined by Aizenman et al. We discuss the Ruelle probability cascades and the stochastic stability within this framework. As an application, we use an idea of Parisi and Talagrand to prove that if a sequence of finite-volume Gibbs measures satisfies the Ghirlanda-Guerra identities, then the infinite-volume measure must be singular as a measure on a Hilbert space.

  5. Preoperative anaemia is associated with increased allogeneic pack red cell transfusion in revision hip and knee joint arthroplasty: a retrospective analysis of 5387 patients over a 10-year period at a single high volume centre.

    Science.gov (United States)

    Kasivisvanathan, R; Ramesh, V; Rao Baikady, R; Nadaraja, S

    2016-08-01

    To estimate the prevalence of preoperative World Health Organization (WHO) defined anaemia in patients presenting for revision hip and knee arthroplasty and its association with transfusion of allogeneic packed red blood cells (PRBC). Studies have mainly investigated the prevalence of preoperative anaemia in primary and not revision hip and knee joint arthroplasty. An analysis of a prospectively collected patient data for 5387 patients having revision hip or knee arthroplasty over a 10-year period at a single high volume centre was conducted. Logistic regression was used to assess whether the presence of WHO defined preoperative anaemia as well as other risk factors were associated with inpatient allogeneic PRBC transfusion. There were 5387 patients assessed of which 3021 (56·01%) patients had revision total hip replacements and 2366 (43·09%) had revision total knee arthroplasty. Of these patients 1956 (36·03%) had preoperative WHO defined anaemia. A total of 2034 (37·08%) patients received at least one unit of allogeneic PRBC during their primary hospital admission. In the final model preoperative WHO defined anaemia was independently associated with allogeneic PRBC transfusion in hip and knee revision surgery OR 4·042 (4·012-4·072 95% CI) CONCLUSIONS: Preoperative anaemia is common in patients presenting for revision hip and knee arthroplasty and independently associated with transfusion of allogeneic PRBC. © 2016 British Blood Transfusion Society.

  6. Dual-energy CT virtual non-calcium technique for detection of bone marrow edema in patients with vertebral fractures: A prospective feasibility study on a single- source volume CT scanner

    Energy Technology Data Exchange (ETDEWEB)

    Diekhoff, T., E-mail: torsten.diekhoff@charite.de [Department of Radiology, Charité - Universitätsmedizin Berlin Campus Mitte, Humboldt-Universität zu Berlin, Freie Universität Berlin, Berlin (Germany); Hermann, K.G. [Department of Radiology, Charité - Universitätsmedizin Berlin Campus Mitte, Humboldt-Universität zu Berlin, Freie Universität Berlin, Berlin (Germany); Pumberger, M. [Department of Spine Surgery, Center for Musculoskeletal Surgery, Charité - Universitätsmedizin Berlin Campus Mitte, Berlin (Germany); Hamm, B. [Department of Radiology, Charité - Universitätsmedizin Berlin Campus Mitte, Humboldt-Universität zu Berlin, Freie Universität Berlin, Berlin (Germany); Putzier, M.; Fuchs, M. [Department of Spine Surgery, Center for Musculoskeletal Surgery, Charité - Universitätsmedizin Berlin Campus Mitte, Berlin (Germany)

    2017-02-15

    Objectives: Dual-energy computed tomography (DECT) is a recent development for detecting bone marrow edema (BME) in patients with vertebral compression fractures. The aim of this pilot study was to determine the reliability of single-source DECT in detecting vertebral BME using magnetic resonance imaging (MRI) as standard of reference. Materials and methods: Nine patients with radiographic thoracic or lumbar vertebral compression fractures underwent both, DECT on a 320-row single-source scanner and 1.5 T MRI. Virtual non-calcium (VNC) images were reconstructed from the DECT volume datasets. Three blinded readers independently scored images for the presence of BME. Only vertebrae with loss of height in radiography (target vertebrae) were included in the analysis. A vertebra was counted as positive if two readers agreed on the presence of BME. Cohen’s kappa was calculated for interrater comparison. Intervertebral ratios of target and the reference vertebra were compared for CT attenuation and MR signal intensity in a reference vertebra using Spearman correlation. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Results: Fourteen target vertebrae with a radiographic height loss were identified; eight of them showed BME on MRI, while DECT identified BME in 7 instances. There were no false positive virtual non-calcium images, resulting in a sensitivity of 0.88 (0.75–1.0 among all readers) and specificity of 1.0 (0.81–1.0). Interrater agreement was inferior for DECT (κ = 0.63–0.89) compared to MRI (κ = 0.9–1.0). Intervertebral ratio in VNC images strongly correlated with short-tau inversion recovery (r = 0.87) and inversely with T1 (-0.89). SNR (0.2 +/− 0.2 in VNC and 16.7 +/− 7.3 in STIR) and CNR (0.2 +/− 0.3 and 7.1 +/− 6.3) values were inferior in VNC. Conclusions: Detecting BME with single-source DECT is feasible and allows detection of vertebral compression fractures with reasonably high sensitivity and specificity

  7. Cardioplegia heat exchanger design modelling using computational fluid dynamics.

    Science.gov (United States)

    van Driel, M R

    2000-11-01

    A new cardioplegia heat exchanger has been developed by Sorin Biomedica. A three-dimensional computer-aided design (CAD) model was optimized using computational fluid dynamics (CFD) modelling. CFD optimization techniques have commonly been applied to velocity flow field analysis, but CFD analysis was also used in this study to predict the heat exchange performance of the design before prototype fabrication. The iterative results of the optimization and the actual heat exchange performance of the final configuration are presented in this paper. Based on the behaviour of this model, both the water and blood fluid flow paths of the heat exchanger were optimized. The simulation predicted superior heat exchange performance using an optimal amount of energy exchange surface area, reducing the total contact surface area, the device priming volume and the material costs. Experimental results confirm the empirical results predicted by the CFD analysis.

  8. Samarium ion exchanged montmorillonite for high temperature cumene cracking reaction

    International Nuclear Information System (INIS)

    Binitha, N.N.

    2009-01-01

    Full text: Nano material Montmorillonite clay is cation exchanged with samarium and its catalytic influence in cumene cracking reaction is investigated. Effect of exchange with sodium ions on further exchange with samarium ions is also noted. Acidity measurements are done using TPD of ammonia. The retention of basic structure is proved from FTIR spectra and XRD patterns. Elemental analysis result shows that samarium exchange has occurred, which is responsible for the higher catalytic activity. Surface area and pore volume remains more or less unaffected upon exchange. Thermogravimetric analysis indicates the enhanced thermal stability on exchanging. Cumene cracking reaction is carried out at atmospheric pressure in a fixed bed glass reactor at 673 K. The predominance of Bronsted acidity is confirmed from high selectivity to benzene. (author)

  9. Baseline design of an OTEC pilot plantship. Volume C. Specifications

    Energy Technology Data Exchange (ETDEWEB)

    Glosten, L. R.; Bringloe, Thomas; Soracco, Dave; Fenstermacher, Earl; Magura, Donald; Sander, Olof; Richards, Dennis; Seward, Jerry

    1979-05-01

    Volume C is part of a three-volume report that presents a baseline engineering design of an Ocean Thermal Energy Conversion (OTEC) plantship. This volume provides the specifications for the hull, cold-water pipe, ship outfitting and machinery, OTEC power system, electrical system, and folded-tube heat exchangers.

  10. Higher Education Exchange, 2010

    Science.gov (United States)

    Brown, David W., Ed.; Witte, Deborah, Ed.

    2010-01-01

    "Higher Education Exchange" publishes case studies, analyses, news, and ideas about efforts within higher education to develop more democratic societies. Contributors to this issue of the "Higher Education Exchange" examine whether institutions of higher learning are doing anything to increase the capacity of citizens to shape their future.…

  11. Higher Education Exchange, 2012

    Science.gov (United States)

    Brown, David W., Ed.; Witte, Deborah, Ed.

    2012-01-01

    "Higher Education Exchange" publishes case studies, analyses, news, and ideas about efforts within higher education to develop more democratic societies. Contributors to this issue of the "Higher Education Exchange" examine whether institutions of higher learning are doing anything to increase the capacity of citizens to shape…

  12. Higher Education Exchange, 2011

    Science.gov (United States)

    Brown, David W., Ed.; Witte, Deborah, Ed.

    2011-01-01

    "Higher Education Exchange" publishes case studies, analyses, news, and ideas about efforts within higher education to develop more democratic societies. Contributors to this issue of the "Higher Education Exchange" examine whether institutions of higher learning are doing anything to increase the capacity of citizens to shape…

  13. French chemical exchange process

    International Nuclear Information System (INIS)

    Frejacques, C.; Lerat, J.-M.; Plurien, P.

    1979-01-01

    A new chemical exchange reaction between two forms of uranium compounds with a high elementary separation coefficient and good kinetics has been discovered at the French Energy Commission ten years ago and developed to the industrial stage. We give here some general characteristics of the process and discuss some parameters of the kinetics exchange

  14. Direct fired heat exchanger

    Science.gov (United States)

    Reimann, Robert C.; Root, Richard A.

    1986-01-01

    A gas-to-liquid heat exchanger system which transfers heat from a gas, generally the combustion gas of a direct-fired generator of an absorption machine, to a liquid, generally an absorbent solution. The heat exchanger system is in a counterflow fluid arrangement which creates a more efficient heat transfer.

  15. Motivation for International Exchange.

    Science.gov (United States)

    Brewer, Elizabeth

    An objective analysis of students' initial motivation for studying overseas was attempted by surveying students before they embarked on their exchange programs. Eighty-eight students who were planning to study in France, Great Britain, Germany, and the People's Republic of China were surveyed. The exchange program was sponsored by the University…

  16. Standardizing exchange formats

    International Nuclear Information System (INIS)

    Lemmel, H.D.; Schmidt, J.J.

    1992-01-01

    An international network of co-operating data centres is described who maintain identical data bases which are simultaneously updated by an agreed data exchange procedure. The agreement covers ''data exchange formats'' which are compatible to the centres' internal data storage and retrieval systems which remain different, optimized at each centre to the available computer facilities and to the needs of the data users. Essential condition for the data exchange is an agreement on common procedures for the data exchange is an agreement on common procedures for the data compilation, including critical data analysis and validation. The systems described (''EXFOR'', ''ENDF'', ''CINDA'') are used for ''nuclear reaction data'', but the principles used for data compilation and exchange should be valid also for other data types. (author). 24 refs, 4 figs

  17. Energy exchange between knee and ankle in a transfemoral prosthesis

    NARCIS (Netherlands)

    Koopman, Hubertus F.J.M.; Behrens, Sebastiaan Maria; Hekman, Edsko E.G.; Ünal, Ramazan

    2013-01-01

    In order to make an energy efficient transfemoral prosthesis, there should be energy exchange between knee and ankle of the prosthesis. A concept containing various spring elements is designed and tested for a single subject. It is shown that the concept of energy exchange can be realized; in this

  18. Wound tube heat exchanger

    Science.gov (United States)

    Ecker, Amir L.

    1983-01-01

    What is disclosed is a wound tube heat exchanger in which a plurality of tubes having flattened areas are held contiguous adjacent flattened areas of tubes by a plurality of windings to give a double walled heat exchanger. The plurality of windings serve as a plurality of effective force vectors holding the conduits contiguous heat conducting walls of another conduit and result in highly efficient heat transfer. The resulting heat exchange bundle is economical and can be coiled into the desired shape. Also disclosed are specific embodiments such as the one in which the tubes are expanded against their windings after being coiled to insure highly efficient heat transfer.

  19. Heat and mass exchanger

    Science.gov (United States)

    Lowenstein, Andrew; Sibilia, Marc J.; Miller, Jeffrey A.; Tonon, Thomas

    2007-09-18

    A mass and heat exchanger includes at least one first substrate with a surface for supporting a continuous flow of a liquid thereon that either absorbs, desorbs, evaporates or condenses one or more gaseous species from or to a surrounding gas; and at least one second substrate operatively associated with the first substrate. The second substrate includes a surface for supporting the continuous flow of the liquid thereon and is adapted to carry a heat exchange fluid therethrough, wherein heat transfer occurs between the liquid and the heat exchange fluid.

  20. HipMatch: an object-oriented cross-platform program for accurate determination of cup orientation using 2D-3D registration of single standard X-ray radiograph and a CT volume.

    Science.gov (United States)

    Zheng, Guoyan; Zhang, Xuan; Steppacher, Simon D; Murphy, Stephen B; Siebenrock, Klaus A; Tannast, Moritz

    2009-09-01

    The widely used procedure of evaluation of cup orientation following total hip arthroplasty using single standard anteroposterior (AP) radiograph is known inaccurate, largely due to the wide variability in individual pelvic orientation relative to X-ray plate. 2D-3D image registration methods have been introduced for an accurate determination of the post-operative cup alignment with respect to an anatomical reference extracted from the CT data. Although encouraging results have been reported, their extensive usage in clinical routine is still limited. This may be explained by their requirement of a CAD model of the prosthesis, which is often difficult to be organized from the manufacturer due to the proprietary issue, and by their requirement of either multiple radiographs or a radiograph-specific calibration, both of which are not available for most retrospective studies. To address these issues, we developed and validated an object-oriented cross-platform program called "HipMatch" where a hybrid 2D-3D registration scheme combining an iterative landmark-to-ray registration with a 2D-3D intensity-based registration was implemented to estimate a rigid transformation between a pre-operative CT volume and the post-operative X-ray radiograph for a precise estimation of cup alignment. No CAD model of the prosthesis is required. Quantitative and qualitative results evaluated on cadaveric and clinical datasets are given, which indicate the robustness and the accuracy of the program. HipMatch is written in object-oriented programming language C++ using cross-platform software Qt (TrollTech, Oslo, Norway), VTK, and Coin3D and is transportable to any platform.

  1. Simplified single plane echocardiography is comparable to conventional biplane two-dimensional echocardiography in the evaluation of left atrial volume: a study validated by three-dimensional echocardiography in 143 individuals.

    Science.gov (United States)

    Vieira-Filho, Normando G; Mancuso, Frederico J N; Oliveira, Wercules A A; Gil, Manuel A; Fischer, Cláudio H; Moises, Valdir A; Campos, Orlando

    2014-03-01

    The left atrial volume index (LAVI) is a biomarker of diastolic dysfunction and a predictor of cardiovascular events. Three-dimensional echocardiography (3DE) is highly accurate for LAVI measurements but is not widely available. Furthermore, biplane two-dimensional echocardiography (B2DE) may occasionally not be feasible due to a suboptimal two-chamber apical view. Simplified single plane two-dimensional echocardiography (S2DE) could overcome these limitations. We aimed to compare the reliability of S2DE with other validated echocardiographic methods in the measurement of the LAVI. We examined 143 individuals (54 ± 13 years old; 112 with heart disease and 31 healthy volunteers; all with sinus rhythm, with a wide range of LAVI). The results for all the individuals were compared with B2DE-derived LAVIs and validated using 3DE. The LAVIs, as determined using S2DE (32.7 ± 13.1 mL/m(2)), B2DE (31.9 ± 12.7 mL/m(2)), and 3DE (33.1 ± 13.4 mL/m(2)), were not significantly different from each other (P = 0.85). The S2DE-derived LAVIs correlated significantly with those obtained using both B2DE (r = 0.98; P Echocardiography criteria for grading LAVI enlargement (normal, mild, moderate, severe), we observed an excellent agreement between the S2DE- and B2DE-derived classifications (κ = 0.89; P < 0.001). S2DE is a simple, rapid, and reliable method for LAVI measurement that may expand the use of this important biomarker in routine echocardiographic practice. © 2013, Wiley Periodicals, Inc.

  2. Retrospective study of renal distribution volume with DTPA-{sup 99m}Tc: performance of single plasma method for glomerular filtration rate estimation; Etude retrospective du volume de distribution du traceur renal DTPA-{sup 99m}Tc: performance d`une methode a un prelevement sanguin pour l`estimation du debit de filtration glomerulaire

    Energy Technology Data Exchange (ETDEWEB)

    Legendre, J.M.; Cledes, J.; Morin, J.F.; Morin, P.P. [Centre Hospitalier Regional Augustin-Morvan, 29 - Brest (France)

    1997-08-01

    169 glomerular filtration rate (GFR) measurements, performed in clinical practice, were analysed for estimation of GFR by several common methods. In one half of patients, we observed that early (2-3-4 hours) and tardive (3-4-5 hours) three point plasma methods were highly correlated, r = 0,998 (n = 82). Even if regression line significantly differed from identify, differences between methods were low (-6, 1 to + 4,4 mL/min/1,73 m{sup 2}). Method with urinary collection was also correlated to plasma methods (r = 0,920 in both cases). Plasma based mean values were higher than that for urinary by 3,6 mL/min/1,73 m{sup 2} (2-3-4 hours) and 3, 1 (3-4-5 hours). Using plasma GFR values and distribution volume, linear and quadratic regressions were tested for GFR = f (V) and GFR = f (In (V)). The lowest observed standard deviation (3,6 mL/min; n = 82) was for GFR{sub 234} = f (V{sub 4h}) using a quadratic equation. This was applied to the second patient group for GFR estimation with 4 hours single point plasma method. Estimations were compared to GFR plasma values. For comparison, GFR estimations were also obtained using the Christensen`s equation. (authors). 17 refs.

  3. Magnetic Exchange Couplings from Local Spin Analysis

    Science.gov (United States)

    Joshi, Rajendra; Abate, Bayileyegn Akanie; Peralta, Juan

    We propose a method to calculate the magnetic exchange coupling parameters in transition metal complexes from a single spin-configuration. Our method uses constraint density functional theory and a local spin population analysis in combination to a non spin formalism to effectively extract the magnetic exchange parameter from the derivative of the electronic energy and spin pair correlation values. We show proof-of-concept calculations on the H-He-H systems and small transition metal complexes. DOE DE-SC0005027.

  4. Data Exchange Inventory System (DEXI)

    Data.gov (United States)

    Social Security Administration — Enterprise tool used to identify data exchanges occurring between SSA and our trading partners. DEXI contains information on both incoming and outgoing exchanges and...

  5. NASA Earth Exchange (NEX)

    Data.gov (United States)

    National Aeronautics and Space Administration — The NASA Earth Exchange (NEX) represents a new platform for the Earth science community that provides a mechanism for scientific collaboration and knowledge sharing....

  6. Research peer exchange, 2014.

    Science.gov (United States)

    2017-08-01

    The WSDOT Research Peer Exchange was held in Olympia, Washington on May 13 and 14, 2014 and addressed Research Program and Project Management as described in the following paragraphs: Program Management There are numerous funding programs, standing c...

  7. Cation Exchange Water Softeners

    Science.gov (United States)

    WaterSense released a notice of intent to develop a specification for cation exchange water softeners. The program has made the decision not to move forward with a spec at this time, but is making this information available.

  8. Active microchannel heat exchanger

    Science.gov (United States)

    Tonkovich, Anna Lee Y [Pasco, WA; Roberts, Gary L [West Richland, WA; Call, Charles J [Pasco, WA; Wegeng, Robert S [Richland, WA; Wang, Yong [Richland, WA

    2001-01-01

    The present invention is an active microchannel heat exchanger with an active heat source and with microchannel architecture. The microchannel heat exchanger has (a) an exothermic reaction chamber; (b) an exhaust chamber; and (c) a heat exchanger chamber in thermal contact with the exhaust chamber, wherein (d) heat from the exothermic reaction chamber is convected by an exothermic reaction exhaust through the exhaust chamber and by conduction through a containment wall to the working fluid in the heat exchanger chamber thereby raising a temperature of the working fluid. The invention is particularly useful as a liquid fuel vaporizer and/or a steam generator for fuel cell power systems, and as a heat source for sustaining endothermic chemical reactions and initiating exothermic reactions.

  9. HUD Exchange Grantee Database

    Data.gov (United States)

    Department of Housing and Urban Development — The About Grantees section of the HUD Exchange brings up contact information, reports, award, jurisdiction, and location data for organizations that receive HUD...

  10. Exchange transfusion - slideshow

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/presentations/100018.htm Exchange transfusion - series—Procedure To use the sharing features on ... M. Editorial team. Related MedlinePlus Health Topics Blood Transfusion and Donation Common Infant and Newborn Problems Jaundice ...

  11. Exchange Risk Management Policy

    CERN Document Server

    2005-01-01

    At the Finance Committee of March 2005, following a comment by the CERN Audit Committee, the Chairman invited the Management to prepare a document on exchange risk management policy. The Finance Committee is invited to take note of this document.

  12. Contact Heat Exchanger

    Science.gov (United States)

    Fleming, M. L.; Stalmach, D. D.; Cox, R. L.

    1985-01-01

    Fluid pressure controls contact between heat pipe and heat exchanger. Heat exchanger system in cross section provides contact interface between fluid system and heat pipe with easy assembly/disassembly of heat-pipe/ pumped-liquid system. Originally developed for use in space, new device applicable on Earth where fluid system is linked with heat pipe, where rapid assembly/disassembly required, or where high pressures or corrosive fluids used.

  13. Hibernation and gas exchange.

    Science.gov (United States)

    Milsom, William K; Jackson, Donald C

    2011-01-01

    Hibernation in endotherms and ectotherms is characterized by an energy-conserving metabolic depression due to low body temperatures and poorly understood temperature-independent mechanisms. Rates of gas exchange are correspondly reduced. In hibernating mammals, ventilation falls even more than metabolic rate leading to a relative respiratory acidosis that may contribute to metabolic depression. Breathing in some mammals becomes episodic and in some small mammals significant apneic gas exchange may occur by passive diffusion via airways or skin. In ectothermic vertebrates, extrapulmonary gas exchange predominates and in reptiles and amphibians hibernating underwater accounts for all gas exchange. In aerated water diffusive exchange permits amphibians and many species of turtles to remain fully aerobic, but hypoxic conditions can challenge many of these animals. Oxygen uptake into blood in both endotherms and ectotherms is enhanced by increased affinity of hemoglobin for O₂ at low temperature. Regulation of gas exchange in hibernating mammals is predominately linked to CO₂/pH, and in episodic breathers, control is principally directed at the duration of the apneic period. Control in submerged hibernating ectotherms is poorly understood, although skin-diffusing capacity may increase under hypoxic conditions. In aerated water blood pH of frogs and turtles either adheres to alphastat regulation (pH ∼8.0) or may even exhibit respiratory alkalosis. Arousal in hibernating mammals leads to restoration of euthermic temperature, metabolic rate, and gas exchange and occurs periodically even as ambient temperatures remain low, whereas body temperature, metabolic rate, and gas exchange of hibernating ectotherms are tightly linked to ambient temperature. © 2011 American Physiological Society.

  14. Real exchange rate misalignments

    OpenAIRE

    Terra, Maria Cristina T.; Valladares, Frederico Estrella Carneiro

    2003-01-01

    This paper characterizes episodes of real appreciations and depreciations for a sample of 85 countries, approximately from 1960 to 1998. First, the equilibrium real exchange rate series are constructed for each country using Goldfajn and Valdes (1999) methodology (cointegration with fundamentals). Then, departures from equilibrium real exchange rate (misalignments) are obtained, and a Markov Switching Model is used to characterize the misalignments series as stochastic autor...

  15. Heat exchanger cleaning

    International Nuclear Information System (INIS)

    Gatewood, J.R.

    1980-01-01

    A survey covers the various types of heat-exchange equipment that is cleaned routinely in fossil-fired generating plants, the hydrocarbon-processing industry, pulp and paper mills, and other industries; the various types, sources, and adverse effects of deposits in heat-exchange equipment; some details of the actual procedures for high-pressure water jetting and chemical cleaning of some specific pieces of equipment, including nuclear steam generators. (DN)

  16. Radial flow heat exchanger

    Science.gov (United States)

    Valenzuela, Javier

    2001-01-01

    A radial flow heat exchanger (20) having a plurality of first passages (24) for transporting a first fluid (25) and a plurality of second passages (26) for transporting a second fluid (27). The first and second passages are arranged in stacked, alternating relationship, are separated from one another by relatively thin plates (30) and (32), and surround a central axis (22). The thickness of the first and second passages are selected so that the first and second fluids, respectively, are transported with laminar flow through the passages. To enhance thermal energy transfer between first and second passages, the latter are arranged so each first passage is in thermal communication with an associated second passage along substantially its entire length, and vice versa with respect to the second passages. The heat exchangers may be stacked to achieve a modular heat exchange assembly (300). Certain heat exchangers in the assembly may be designed slightly differently than other heat exchangers to address changes in fluid properties during transport through the heat exchanger, so as to enhance overall thermal effectiveness of the assembly.

  17. Kinetic Analyses of Cation Exchange Rates in Synthetic Birnessite Measured by Time- Resolved Synchrotron X-ray Diffraction

    Science.gov (United States)

    Lopano, C. L.; Heaney, P. J.; Post, J. E.; Bandstra, J.; Brantley, S. L.

    2006-05-01

    Birnessite is the most abundant and chemically important layer-structure Mn-oxide phase found in soils, desert varnishes, and ocean nodules. It also is industrially important for use in battery technology and octahedral sieves. Due to the poorly crystalline nature of natural birnessite, synthetic analogues typically have been employed in studies that explore the structural response of birnessite to variations in interlayer composition. For this work, we measured changes in unit-cell parameters over time to quantify the degree of cation exchange as a function of concentration. Aqueous K+, Cs+, and Ba2+ cations at varying concentrations at pH 7 were exchanged for interlayer Na+ in synthetic birnessite (Na0.58(Mn4+1.42,Mn3+0.58)O4·1.5H2O) using a simple flow- through cell, and the exchange products were monitored via time-resolved X-ray powder diffraction at the National Synchrotron Light Source. Powder X-ray diffraction patterns were collected every 2-3 minutes. Rietveld analyses of X-ray diffraction patterns for K- and Ba-exchanged birnessite revealed a decrease in unit- cell volume over time. In contrast, Cs+ substitution increased cell volume. For all three cations, the crystallographic data indicate that exchange occurred in two stages. A rapid and dramatic change in unit-cell volume was followed by a modest adjustment over longer timescales. Fourier electron difference syntheses revealed that the rapid, initial stage of exchange was marked by re-configuration of the interlayer species, whereas the second, protracted phase of substitution represented ordering into the newly established interlayer positions. For the first time, we have modeled the kinetics of interlayer substitution in Na-birnessite. For purposes of comparison, we have employed a simple one-stage reaction (i.e., Na-birnessite → K-birnessite) and a two stage reaction (i.e,. Na-birnessite → K-birnessitedisordered → K- birnessiteordered). For exchange with 0.01 M KCl solutions, the single

  18. Exchange Rate Volatility and Trade Equation in Indonesia

    Science.gov (United States)

    Pasasa, Linus; Fechter, Nadine; Bustaman, Yosman

    2010-12-01

    This paper examines the characteristics of short-term and long-term fluctuations/volatility of Indonesia exchange rate and investigates whether this volatility has affected Indonesia's exports flows. In particular the paper investigates the impact of exchange rate volatility on aggregate Indonesia exports flows to the United State and also on imports. The Augmented Dickey-Fuller Test was employed on quarterly data for the period January 2000 to December 2008 to test for stationarity on the variables of interest. Estimates of the long-term influence of exchange rate volatility on the trade flows are obtained using the Johansen Cointegration Test. The results suggest that a significant long-term relationship linking exchange rate volatility and the trade volume between Indonesia and the United States exists. A negative long-term relationship between exchange rate fluctuations and the export volume sent from Indonesia to the US is obtained. On the other hand, exchange rate volatility exerts a positive long-term effect upon the import volume.

  19. The effects of frost thickness on the heat transfer of finned tube heat exchanger subject to the combined influence of fan types

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Jeng-Min; Hsieh, Wen-Chien; Ke, Xin-Ji [Department of Refrigeration, Air Conditioning National Chin-Yi University of Technology, Taichung County, Taiping City 411 (China); Wang, Chi-Chuan [Energy and Environment Research Laboratories, Industrial Technology Research Institute, Hsinchu 310 (China)

    2008-05-15

    This study conducts a numerical study concerning the effect of frost thickness on the heat transfer performance of a four rows plate finned tube heat exchanger. Calculations are made under constant air volume and variable air volume conditions. It is found that the initial surge of heat transfer rate in the frosted finned tube heat exchanger is mainly associated with the critical radius effect rather than the surface roughness. The frost thermal conductivity plays an important role in the surge phenomenon. There is hardly any initial surge when frost thermal conductivity is below 0.1 W m{sup -1} K{sup -1}. It is also recommended that a refrigerator should defrost when half of a single flow channel area is blocked by frost. The calculations also reveal that a centrifugal fan is recommended with a small fin-pitch heat exchanger. However, if a long term operation at a thick frost situation is unavoidable, an axial fan should be selected. There is no great difference between selection of an axial fan or centrifugal fan for a larger fin pitch heat exchanger. (author)

  20. Mass-charge-heat coupled transfers in a single cell of a proton exchange membrane fuel cell; Transferts couples masse-charge-chaleur dans une cellule de pile a combustible a membrane polymere

    Energy Technology Data Exchange (ETDEWEB)

    Ramousse, J.

    2005-11-15

    Understanding and modelling of coupled mass, charges and heat transfers phenomena are fundamental to analyze the electrical behaviour of the system. The aim of the present model is to describe electrical performances of a PEFMC according to the fluidic and thermal operating conditions. The water content of the membrane and the water distribution in the single cell are estimated according to the coupled simulations of mass transport in the thickness of the single cell and in the feeding channels of the bipolar plates. A microscopic model of a Gas Diffusion Electrode is built up to describe charges transfer phenomena occurring at the electrodes. Completed by a study of heat transfer in the Membrane Electrode Assembly, conditions and preferential sites of water vapor condensation can be highlighted. A set of measurements of the effective thermal conductivity of carbon felts used in fuel cells as porous backing layers have also been performed. Although the value of this parameter is essential for the study of heat transfer, it is still under investigation because of the strong thermal anisotropy of the medium. (author)

  1. Single-Molecule Spectroscopy

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 20; Issue 2. Single-Molecule Spectroscopy: Every Molecule is Different! ... Author Affiliations. Kankan Bhattacharyya1. Department of Physical Chemistry, Indian Association for the Cultivation of Science Jadavpur, Kolkata 700 032 India.

  2. Renormalized Volume

    Science.gov (United States)

    Gover, A. Rod; Waldron, Andrew

    2017-09-01

    We develop a universal distributional calculus for regulated volumes of metrics that are suitably singular along hypersurfaces. When the hypersurface is a conformal infinity we give simple integrated distribution expressions for the divergences and anomaly of the regulated volume functional valid for any choice of regulator. For closed hypersurfaces or conformally compact geometries, methods from a previously developed boundary calculus for conformally compact manifolds can be applied to give explicit holographic formulæ for the divergences and anomaly expressed as hypersurface integrals over local quantities (the method also extends to non-closed hypersurfaces). The resulting anomaly does not depend on any particular choice of regulator, while the regulator dependence of the divergences is precisely captured by these formulæ. Conformal hypersurface invariants can be studied by demanding that the singular metric obey, smoothly and formally to a suitable order, a Yamabe type problem with boundary data along the conformal infinity. We prove that the volume anomaly for these singular Yamabe solutions is a conformally invariant integral of a local Q-curvature that generalizes the Branson Q-curvature by including data of the embedding. In each dimension this canonically defines a higher dimensional generalization of the Willmore energy/rigid string action. Recently, Graham proved that the first variation of the volume anomaly recovers the density obstructing smooth solutions to this singular Yamabe problem; we give a new proof of this result employing our boundary calculus. Physical applications of our results include studies of quantum corrections to entanglement entropies.

  3. Bifunctional thermoelectric tube made of tilted multilayer material as an alternative to standard heat exchangers.

    Science.gov (United States)

    Takahashi, Kouhei; Kanno, Tsutomu; Sakai, Akihiro; Tamaki, Hiromasa; Kusada, Hideo; Yamada, Yuka

    2013-01-01

    Enormously large amount of heat produced by human activities is now mostly wasted into the environment without use. To realize a sustainable society, it is important to develop practical solutions for waste heat recovery. Here, we demonstrate that a tubular thermoelectric device made of tilted multilayer of Bi(0.5)Sb(1.5)Te3/Ni provides a promising solution. The Bi(0.5)Sb(1.5)Te3/Ni tube allows tightly sealed fluid flow inside itself, and operates in analogy with the standard shell and tube heat exchanger. We show that it achieves perfect balance between efficient heat exchange and high-power generation with a heat transfer coefficient of 4.0 kW/m(2)K and a volume power density of 10 kW/m(3) using low-grade heat sources below 100°C. The Bi(0.5)Sb(1.5)Te3/Ni tube thus serves as a power generator and a heat exchanger within a single unit, which is advantageous for developing new cogeneration systems in factories, vessels, and automobiles where cooling of excess heat is routinely carried out.

  4. Analytical 1D models of the wall thermal resistance of rectangular minichannels applied in heat exchangers

    Directory of Open Access Journals (Sweden)

    Rybiński Witold

    2016-09-01

    Full Text Available The paper presents four 1-dimensional models of thermal resistance of walls in a heat exchanger with rectangular minichannels. The first model is the simplest one, with a single wall separating two fluids. The second model of the so called equivalent wall takes into account total volume of intermediate walls between layers of minichannels and of side walls of minichannels. The next two more complicated models take separately into account thermal resistance of these walls. In these two models side walls are treated as fins. The results of models comparison are presented. It is shown that thermal resistance may be neglected for metal walls but it should be taken into account for the walls made of plastics. For the case of non-neglected wall thermal resistance the optimum wall thickness was derived. Minichannel heat exchangers made of plastic are larger than those built of metal, but are significantly cheaper. It makes possible to use of such exchangers in inexpensive microscale ORC installations.

  5. Heat exchanger for coal gasification process

    Science.gov (United States)

    Blasiole, George A.

    1984-06-19

    This invention provides a heat exchanger, particularly useful for systems requiring cooling of hot particulate solids, such as the separated fines from the product gas of a carbonaceous material gasification system. The invention allows effective cooling of a hot particulate in a particle stream (made up of hot particulate and a gas), using gravity as the motive source of the hot particulate. In a preferred form, the invention substitutes a tube structure for the single wall tube of a heat exchanger. The tube structure comprises a tube with a core disposed within, forming a cavity between the tube and the core, and vanes in the cavity which form a flow path through which the hot particulate falls. The outside of the tube is in contact with the cooling fluid of the heat exchanger.

  6. 75 FR 8769 - Self-Regulatory Organizations; BATS Exchange, Inc.; Order Approving Proposed Rule Change, as...

    Science.gov (United States)

    2010-02-25

    ... certain physical ports\\6\\ used to connect to the Exchange's system for order entry and receipt of data... additional single physical port provided by the Exchange to any Member or non- member in any data center. The... one port at the site of the Exchange's primary data center (including the expansion space located...

  7. Tensor exchange amplitudes in K +- N charge exchange reactions

    International Nuclear Information System (INIS)

    Svec, M.

    1979-01-01

    Tensor (A 2 ) exchange amplitudes in K +- N charge exchange (CEX) are constructed from the K +- N CEX data supplemented by information on the vector (rho) exchange amplitudes from πN sca tering. We observed new features in the t-structure of A 2 exchange amplitudes which contradict the t-de pendence anticipated by most of the Regge models. The results also provide evidence for violation of weak exchange degeneracy

  8. Pion double charge exchange in the Δ33 resonance region

    International Nuclear Information System (INIS)

    Wirzba, A.; Toki, H.; Siciliano, E.R.; Johnson, M.B.; Gilman, R.

    1989-01-01

    We examine the model dependence and nuclear-structure sensitivity of several Δ 33 -dominated processes contributing to pion double charge exchange on nuclei in the region of the Δ 33 resonance. These processes include the Δ 33 -nucleon interaction V NΔ and sequential scattering, in which the pion undergoes single charge exchange on two different nucleons. In all cases, the scattering takes place through the exchange of an intermediate π and ρ meson. Sequential-mediated double charge exchange is found to be only moderately sensitive to short-range correlations, meson-nucleon form factors, and the rho meson, whereas V NΔ -mediated double charge exchange is very sensitive to all these effects. Results are given for double charge exchange on 18 O (double isobaric analog transitions) and 16 O (nonanalog transitions). Sequential double charge exchange is shown to favor non-spin-flip matrix elements of the transition operator whereas V NΔ -mediated double charge exchange favors spin-flip matrix elements. The energy dependence of the zero-degree cross sections for V NΔ and sequential scattering are also different: Sequential tends to increase monotonically from 100 to 300 MeV, whereas V NΔ peaks at about 150 MeV. The delta-nucleon interaction is found likely to dominate over sequential scattering in nonanalog double charge exchange. The V NΔ is also large in analog double charge exchange, but it does not enable us to explain the anomalous behavior of the 18 O differential cross sections

  9. Application of an improved operational strategy for a high temperature-proton exchange membrane fuel cell-based micro-combined heat and power system for Danish single-family households

    DEFF Research Database (Denmark)

    Arsalis, Alexandros; Nielsen, Mads Pagh; Kær, Søren Knudsen

    2013-01-01

    characteristics. Based on these findings, an improved operational strategy is formulated and applied in an attempt to minimize the shortcomings of conventional strategies. System parameters, such as electrical and thermal efficiencies, heat dumping, and import/export of electricity, are analyzed. The applied load......A proposed residential energy system based on the PBI (Polybenzimidazole) fuel cell technology is analyzed in terms of operational performance. Conventional operational strategies, such as heat-led and electricity-led, are applied to the simulated system to investigate their performance...... profile is based on average data for a single-family household in Denmark and includes consumption data for electricity and heat demands. The study analyzes the potential of the proposed system on market penetration in the area of residential heat-and-power generation and whether this deployment can...

  10. Single-ion anisotropy and exchange interactions in the cyano-bridged trimers MnIII2MIII(CN)6 (MIII = Co, Cr, Fe) species incorporating [Mn(5-Brsalen)]+ units: an inelastic neutron scattering and magnetic susceptibility study

    DEFF Research Database (Denmark)

    Tregenna-Piggott, Philip L W; Sheptyakov, Denis; Keller, Lukas

    2009-01-01

    expectations based on the unquenched orbital angular momentum of the [Fe(CN)(6)](3-) anion, giving rise to an M(s) approximately +/-9/2 ground state, isolated by approximately 11.5 cm(-1) from the higher-lying levels. The reported INS and magnetic data should now serve as a benchmark against which theoretical...... interactions that define the low-lying states of the Mn-M(III)-Mn trimeric units. Despite the presence of an antiferromagnetic intertrimer interaction, the experimental evidence supports the classification of both the Cr(III) and Fe(III) compounds as single-molecule magnets. The value of 17(2) cm(-1...

  11. Fundamental structural aspects and features in the bioengineering of the gas exchangers: comparative perspectives.

    Science.gov (United States)

    Maina, J N

    2002-01-01

    generally those of reptiles, whereas a single capillary design commonly occurs in those of adult mammals. The capillary loading (the ratio of the volume of the capillary blood to the surface area across which blood is exposed to air) in lungs with a double capillary arrangement is high and manifests a poor design. On the other hand, the low capillary loading that characterizes the single capillary system indicates better exposure of blood to air and greater respiratory capacity. Fractal geometry features in the construction of the gas exchangers. The highly versatile design allows the gas exchangers to function optimally under different conditions and circumstances and to maintain congruent morphologies over a wide range of body size, shape and metabolic capacities. At the gas exchange level, sheet-flow design preponderates in the evolved gas exchangers; blood is efficiently exposed to the external respiratory medium. The respiratory capacity of a gas exchanger is comprehensively granted by refinements of structural features and functional processes. Modelling, mathematical integration of structural and functional parameters, provides a holistic view of the essence of the design of a gas exchanger.

  12. Exchanging Description Logic Knowledge Bases

    NARCIS (Netherlands)

    Arenas, M.; Botoeva, E.; Calvanese, D.; Ryzhikov, V.; Sherkhonov, E.

    2012-01-01

    In this paper, we study the problem of exchanging knowledge between a source and a target knowledge base (KB), connected through mappings. Differently from the traditional database exchange setting, which considers only the exchange of data, we are interested in exchanging implicit knowledge. As

  13. ADVISABILITY OF MERGING THE BUCHAREST STOCK EXCHANGE AND THE SIBIU MONETARYFINANCIAL AND STOCK EXCHANGE

    Directory of Open Access Journals (Sweden)

    Aura Dudas

    2011-01-01

    Full Text Available Analysis of performances of local stock exchanges in the latest years points out thenecessity of increasing the visibility of the local capital market in the regional andEuropean landscape. A single stock market may have the effect of increased credibility,giving thus an impulse to the number of new listings and of new investors.

  14. Geographic exchange standard and primer

    Energy Technology Data Exchange (ETDEWEB)

    1978-10-01

    The ANSI Draft Proposal Specifications for an Information Interchange Data Descriptive File, X3L5.SEP, contains some Guidelines for Implementation (Appendix D). However, some additional guidelines should be provided specifically for the more commonly used systems of coding locational data, and referring thematic data to those codes. While there is no consensus that a single, preferred representation of geographical files can be specified as a standard for exchange, there is agreement on the generic form of record structures for commonly used, two-dimensional files. This report surveys by example common practice and illustrates the use of geocodes as thematic data pointers. It defines the elements of the structures as a subsystem within the interchange standard. An implementation within the Levels of Implementation of the basic IWGDE Standard is proposed and examples for some of the defined file types are presented in numerical form to aid in understanding. The problem of referring thematic data to a geographic file when these data reside in a physically distinct exchange file is discussed. 14 figures, 1 table. (RWR)

  15. Heat exchanger restart evaluation

    International Nuclear Information System (INIS)

    Morrison, J.M.; Hirst, C.W.; Lentz, T.F.

    1992-01-01

    On December 24, 1991, the K-Reactor was in the shutdown mode with full AC process water flow and full cooling water flow. Safety rod testing was being performed as part of the power ascension testing program. The results of cooling water samples indicated tritium concentrations higher than allowable. Further sampling and testing confirmed a Process Water System to Cooling Water System leak in heat exchanger 4A (HX 4A). The heat exchanger was isolated and the plant shutdown. Heat exchanger 4A was removed from the plant and moved to C-Area prior to performing examinations and diagnostic testing. This included locating and identifying the leaking tube or tubes, eddy current examination of the leaking tube and a number of adjacent tubes, visually inspecting the leaking tube from both the inside as well as the area surrounding the identified tube. The leaking tube was removed and examined metallurgically to determine the failure mechanism. In addition ten other tubes that either exhibited eddy current indications or would represent a baseline condition were removed from heat exchanger 4A for metallurgical examination. Additional analysis and review of heat exchanger leakage history was performed to determine if there are any patterns which can be used for predictive purposes. Compensatory actions have been taken to improve the sensitivity and response time to any future events of this type. The results of these actions are summarized

  16. Heat exchanger restart evaluation

    International Nuclear Information System (INIS)

    Morrison, J.M.; Hirst, C.W.; Lentz, T.F.

    1992-01-01

    On December 24, 1991, the K-Reactor was in the shutdown mode with full AC process water flow and full cooling water flow. Safety rod testing was being performed as part of the power ascension testing program. The results of cooling water samples indicated tritium concentrations higher than allowable. Further sampling and testing confirmed a Process Water System to Cooling Water System leak in heat exchanger 4A (HX 4A). The heat exchanger was isolated and the plant shutdown. Heat exchanger 4A was removed from the plant and moved to C-Area prior to performing examinations and diagnostic testing. This included locating and identifying the leaking tube or tubes, eddy current examination of the leaking tube and a number of adjacent tubes, visually inspecting the leaking tube from both the inside as well as the area surrounding the identified tube. The leaking tube was removed and examined metallurgically to determine the failure mechanism. In addition ten other tubes that either exhibited eddy current indications or would represent a baseline condition were removed from heat exchanger 4A for metallurgical examination. Additional analysis and review of heat exchanger leakage history was performed to determine if there are any patterns which can be used for predictive purposes. Compensatory actions have been taken to improve the sensitivity and response time to any future events of this type. The results of these actions are summary herein

  17. Heat exchanger restart evaluation

    International Nuclear Information System (INIS)

    Morrison, J.M.; Hirst, C.W.; Lentz, T.F.

    1992-01-01

    On December 24, 1991, the K-Reactor was in the shutdown mode with full AC process water flow and full cooling water flow. Safety rod testing was being performed as part of the power ascension testing program. The results of cooling water samples indicated tritium concentrations higher than allowable. Further sampling and testing confirmed a Process Water System to Cooling Water System leak in heat exchanger 4A (HX 4A). The heat exchanger was isolated and the plant shutdown. Heat exchanger 4kA was removed from the plant and moved to C-Area prior to performing examinations and diagnostic testing. This included locating and identifying the leaking tube or tubes, eddy current examination of the leaking tube and a number of adjacent tubes, visually inspecting the leaking tube from both the inside as well as the area surrounding the failure mechanism. In addition ten other tubes that either exhibited eddy current indications or would represent a baseline condition were removed from heat exchanger 4A for metallurgical examination. Additional analysis and review of heat exchanger leakage history was performed to determine if there are any patterns which can be used for predictive purposes. Compensatory actions have been taken to improve the sensitivity and response time to any future events of this type. The results of these actions are summarized herein

  18. 76 FR 13681 - Self-Regulatory Organizations; BATS Y-Exchange, Inc.; Notice of Filing and Immediate...

    Science.gov (United States)

    2011-03-14

    ... higher volumes of liquidity. The Exchange also proposes to increase its fee to add non-displayed... Under/Better,'' rather than ``One Under,'' and to add reference to EDGA. 2. Statutory Basis The Exchange... offering competitive rates to Exchange Members for strategies that first check the BYX order book before...

  19. Fouling reduction characteristics of a no-distributor-fluidized-bed heat exchanger for flue gas heat recovery

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Y.D.; Lee, K.B.; Islam, S.Z.; Ko, S.B. [Kongju National University, Kong Ju (Republic of Korea). Dept. for Mechanical Engineering

    2008-07-01

    In conventional flue gas heat recovery systems, the fouling by fly ashes and the related problems such as corrosion and cleaning are known to be major drawbacks. To overcome these problems, a single-riser no-distributor-fluidized-bed heat exchanger is devised and studied. Fouling and cleaning tests are performed for a uniquely designed fluidized bed-type heat exchanger to demonstrate the effect of particles on the fouling reduction and heat transfer enhancement. The tested heat exchanger model (1 m high and 54 mm internal diameter) is a gas-to-water type and composed of a main vertical tube and four auxiliary tubes through which particles circulate and transfer heat. Through the present study, the fouling on the heat transfer surface could successfully be simulated by controlling air-to-fuel ratios rather than introducing particles through an external feeder, which produced soft deposit layers with 1 to 1.5 mm thickness on the inside pipe wall. Flue gas temperature at the inlet of heat exchanger was maintained at 450{sup o}C at the gas volume rate of 0.738 to 0.768 CMM (0.0123 to 0.0128 m{sup 3}/sec). From the analyses of the measured data, heat transfer performances of the heat exchanger before and after fouling and with and without particles were evaluated. Results showed that soft deposits were easily removed by introducing glass bead particles, and also heat transfer performance increased two times by the particle circulation. In addition, it was found that this type of heat exchanger had high potential to recover heat of waste gases from furnaces, boilers, and incinerators effectively and to reduce fouling related problems.

  20. Microgravity condensing heat exchanger

    Science.gov (United States)

    Thomas, Christopher M. (Inventor); Ma, Yonghui (Inventor); North, Andrew (Inventor); Weislogel, Mark M. (Inventor)

    2011-01-01

    A heat exchanger having a plurality of heat exchanging aluminum fins with hydrophilic condensing surfaces which are stacked and clamped between two cold plates. The cold plates are aligned radially along a plane extending through the axis of a cylindrical duct and hold the stacked and clamped portions of the heat exchanging fins along the axis of the cylindrical duct. The fins extend outwardly from the clamped portions along approximately radial planes. The spacing between fins is symmetric about the cold plates, and are somewhat more closely spaced as the angle they make with the cold plates approaches 90.degree.. Passageways extend through the fins between vertex spaces which provide capillary storage and communicate with passageways formed in the stacked and clamped portions of the fins, which communicate with water drains connected to a pump externally to the duct. Water with no entrained air is drawn from the capillary spaces.

  1. Multicomponent ion exchange model

    International Nuclear Information System (INIS)

    Robinson, S.M.; Arnold, W.D.; Byers, C.H.

    1990-01-01

    The optimization of ion-exchange column design becomes increasingly important in applications where high efficiency is required to remove trace components in wastewater to very low discharge requirements and for treating hazardous wastewaters where the disposal costs for secondary waste is extremely high. A predictive mathematical model is being developed for improved design of ion-exchange columns for treatment of wastewaters which are contaminated with trace quantities of Sr-90 and Cs-137. Equilibria isotherms and mass transfer mechanisms are being experimentally determined for isothermal multicomponent ion exchange of Ca, Mg, Na, Ca, and Sr with Ionsive IE-95 chabazite zeolite. These equations are being included in a mathematical model to determine the cation breakthrough curves for different column configurations and operating conditions

  2. Sorption by cation exchange

    International Nuclear Information System (INIS)

    Bradbury, M.H.; Baeyens, B.

    1994-04-01

    A procedure for introducing exchange into geochemical/surface complexation codes is described. Beginning with selectivity coefficients, K c , defined in terms of equivalent fractional ion occupancies, a general expression for the molar based exchange code input parameters, K ex , is derived. In natural systems the uptake of nuclides onto complex sorbents often occurs by more than one mechanism. The incorporation of cation exchange and surface complexation into a geochemical code therefore enables sorption by both mechanisms to be calculated simultaneously. The code and model concepts are tested against sets of experimental data from widely different sorption studies. A proposal is made to set up a data base of selectivity coefficients. Such a data base would form part of a more general one consisting of sorption mechanism specific parameters to be used in conjunction with geochemical/sorption codes to model and predict sorption. (author) 6 figs., 6 tabs., 26 refs

  3. Modular heat exchanger

    Science.gov (United States)

    Culver, Donald W.

    1978-01-01

    A heat exchanger for use in nuclear reactors includes a heat exchange tube bundle formed from similar modules each having a hexagonal shroud containing a large number of thermally conductive tubes which are connected with inlet and outlet headers at opposite ends of each module, the respective headers being adapted for interconnection with suitable inlet and outlet manifold means. In order to adapt the heat exchanger for operation in a high temperature and high pressure environment and to provide access to all tube ports at opposite ends of the tube bundle, a spherical tube sheet is arranged in sealed relation across the chamber with an elongated duct extending outwardly therefrom to provide manifold means for interconnection with the opposite end of the tube bundle.

  4. Ion exchange phenomena

    Energy Technology Data Exchange (ETDEWEB)

    Bourg, I.C.; Sposito, G.

    2011-05-01

    Ion exchange phenomena involve the population of readily exchangeable ions, the subset of adsorbed solutes that balance the intrinsic surface charge and can be readily replaced by major background electrolyte ions (Sposito, 2008). These phenomena have occupied a central place in soil chemistry research since Way (1850) first showed that potassium uptake by soils resulted in the release of an equal quantity of moles of charge of calcium and magnesium. Ion exchange phenomena are now routinely modeled in studies of soil formation (White et al., 2005), soil reclamation (Kopittke et al., 2006), soil fertilitization (Agbenin and Yakubu, 2006), colloidal dispersion/flocculation (Charlet and Tournassat, 2005), the mechanics of argillaceous media (Gajo and Loret, 2007), aquitard pore water chemistry (Tournassat et al., 2008), and groundwater (Timms and Hendry, 2007; McNab et al., 2009) and contaminant hydrology (Chatterjee et al., 2008; van Oploo et al., 2008; Serrano et al., 2009).

  5. Isotopic exchange of deuterium in zeolites

    International Nuclear Information System (INIS)

    Novakova, J.; Kubelkova, L.; Jiru, P.

    1981-01-01

    The information obtainable from the study of deuterium isotope exchange in zeolites by i.r. and m.s. methods is discussed. The conditions necessary for high sensitivity determination of OH groups by gas-phase analysis are mentioned together with a determination of the hydroxyl number in the 3 types of OH groups found in HNaY zeolite by solid-phase analysis. The advantage of the i.r. method in the study of hydroxyl heterogeneity in isotopic exchange is compared with the limited success of the m.s. method. The evaluation of the rates of homo- and hetero-exchange and their dependences on cationic exchange, stabilization and the pretreatment of Msup(n+)HY zeolites are shown. The activation of hydrogen molecules seems to be the slowest step in the exchange which proceeds by a single-step mechanism. The OH groups alone do not activate hydrogen molecules as opposed to Lewis sites formed by dehydroxylation and cations and/or metal particles in suitable concentrations at suitable locations. (author)

  6. Porosity, single-phase permeability, and capillary pressure data from preliminary laboratory experiments on selected samples from Marker Bed 139 at the Waste Isolation Pilot Plant. Volume 3 of 3: Appendices C, D, E, and F

    International Nuclear Information System (INIS)

    Howarth, S.M.; Christian-Frear, T.

    1997-08-01

    This volume contains the mineralogy, porosity, and permeability results from the Marker Bed 139 anhydrite specimens evaluated by TerraTek, Inc. for the Waste Isolation Pilot Plant. This volume also documents the brine recipe used by RE/SPEC, Inc., the parameter package submitted to Performance Assessment based on all the data, and a memo on the mixed Brooks and Corey two-phase characteristic curves

  7. Porosity, single-phase permeability, and capillary pressure data from preliminary laboratory experiments on selected samples from Marker Bed 139 at the Waste Isolation Pilot Plant. Volume 3 of 3: Appendices C, D, E, and F

    Energy Technology Data Exchange (ETDEWEB)

    Howarth, S.M.; Christian-Frear, T.

    1997-08-01

    This volume contains the mineralogy, porosity, and permeability results from the Marker Bed 139 anhydrite specimens evaluated by TerraTek, Inc. for the Waste Isolation Pilot Plant. This volume also documents the brine recipe used by RE/SPEC, Inc., the parameter package submitted to Performance Assessment based on all the data, and a memo on the mixed Brooks and Corey two-phase characteristic curves.

  8. Heat exchanger panel

    Science.gov (United States)

    Warburton, Robert E. (Inventor); Cuva, William J. (Inventor)

    2005-01-01

    The present invention relates to a heat exchanger panel which has broad utility in high temperature environments. The heat exchanger panel has a first panel, a second panel, and at least one fluid containment device positioned intermediate the first and second panels. At least one of the first panel and the second panel have at least one feature on an interior surface to accommodate the at least one fluid containment device. In a preferred embodiment, each of the first and second panels is formed from a high conductivity, high temperature composite material. Also, in a preferred embodiment, the first and second panels are joined together by one or more composite fasteners.

  9. Classification of exchange currents

    International Nuclear Information System (INIS)

    Friar, J.L.

    1983-01-01

    After expansion of the vector and axial vector currents in powers of (v/c), a heretofore unremarked regularity results. Meson exchange currents can be classified into types I and II, according to the way they satisfy the constraints of special relativity. The archetypes of these two categories are the impulse approximation to the vector and axial vector currents. After a brief discussion of these constraints, the (rhoπγ) and (ωsigmaγ) exchange currents are constructed and classified, and used to illustrate a number of important points which are often overlooked

  10. Single molecules and nanotechnology

    CERN Document Server

    Vogel, Horst

    2007-01-01

    This book focuses on recent advances in the rapidly evolving field of single molecule research. These advances are of importance for the investigation of biopolymers and cellular biochemical reactions, and are essential to the development of quantitative biology. Written by leading experts in the field, the articles cover a broad range of topics, including: quantum photonics of organic dyes and inorganic nanoparticles their use in detecting properties of single molecules the monitoring of single molecule (enzymatic) reactions single protein (un)folding in nanometer-sized confined volumes the dynamics of molecular interactions in biological cells The book is written for advanced students and scientists who wish to survey the concepts, techniques and results of single molecule research and assess them for their own scientific activities.

  11. The Effect of Exchange Rate Volatility on Iran’s Raisin Export

    OpenAIRE

    2014-01-01

    Exchange rate volatility is one of the effective and ambiguous factors in agricultural product export. Considering the importance of agricultural trade to avoid single-product economy, the main aim of this study was to investigate the impact of exchange rate volatility on the Raisin export of Iran during the years1959-2011. For this purpose, exchange rate volatility index was estimated using Moving Average Standard Deviation (MASD). Then, the impact of exchange rate volatility on the value of...

  12. Ligand Exchange Kinetics of Environmentally Relevant Metals

    Energy Technology Data Exchange (ETDEWEB)

    Panasci, Adele Frances [Univ. of California, Davis, CA (United States)

    2014-07-15

    The interactions of ground water with minerals and contaminants are of broad interest for geochemists but are not well understood. Experiments on the molecular scale can determine reaction parameters (i.e. rates of ligand exchange, activation entropy, activation entropy, and activation volume) that can be used in computations to gain insight into reactions that occur in natural groundwaters. Experiments to determine the rate of isotopic ligand exchange for three environmentally relevant metals, rhodium (Rh), iron (Fe), and neptunium (Np), are described. Many environmental transformations of metals (e.g. reduction) in soil occur at trivalent centers, Fe(III) in particular. Contaminant ions absorb to mineral surfaces via ligand exchange, and the reversal of this reaction can be dangerous, releasing contaminants into the environment. Ferric iron is difficult to study spectroscopically because most of its complexes are paramagnetic and are generally reactive toward ligand exchange; therefore, Rh(III), which is diamagnetic and less reactive, was used to study substitution reactions that are analogous to those that occur on mineral oxide surfaces. Studies on both Np(V) and Np(VI) are important in their own right, as 237Np is a radioactive transuranic element with a half-life of 2 million years.

  13. Algorithmic Trading at Bucharest Stock Exchange

    Directory of Open Access Journals (Sweden)

    Adrian Victor SĂNDIŢĂ

    2015-09-01

    Full Text Available Very conservative estimates indicate that over 40% of transactions on the stock exchanges in the United States are based on automatically generated orders. Such systems are designed to do algorithmic trading on the basis of a predefined set of rules that determine the composition of the portfolio and the moment in which the purchases and sales of securities are done. Applying highly diverse trading strategies, algorithmic trading systems ultimately aim to maximize profit and minimize risk taking. Algorithmic trading on the Bucharest Stock Exchange is still in its incipient phase. Now, automated trading systems are used only for participants who act as Market Makers for the actions of a few issuers. Estimates indicate a volume of algorithmic trading on the Bucharest Stock Exchange of under 1% of its total transactions. This paper aims to describe a general way that algorithmic trading systems can be connected to the Bucharest Stock Exchange and to present some of our results in the implementation of such a system.

  14. Nature's Heat Exchangers.

    Science.gov (United States)

    Barnes, George

    1991-01-01

    Discusses the heat-transfer systems of different animals. Systems include heat conduction into the ground, heat transferred by convection, heat exchange in lizards, fish and polar animals, the carotid rete system, electromagnetic radiation from animals and people, and plant and animal fiber optics. (MDH)

  15. Chapter 11. Heat Exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Rafferty, Kevin D.; Culver, Gene

    1998-01-01

    Most geothermal fluids, because of their elevated temperature, contain a variety of dissolved chemicals. These chemicals are frequently corrosive toward standard materials of construction. As a result, it is advisable in most cases to isolate the geothermal fluid from the process to which heat is being transferred. The task of heat transfer from the geothermal fluid to a closed process loop is most often handled by a plate heat exchanger. The two most common types used in geothermal applications are: bolted and brazed. For smaller systems, in geothermal resource areas of a specific character, downhole heat exchangers (DHEs) provide a unique means of heat extraction. These devices eliminate the requirement for physical removal of fluid from the well. For this reason, DHE-based systems avoid entirely the environmental and practical problems associated with fluid disposal. Shell and tube heat exchangers play only a minor role in low-temperature, direct-use systems. These units have been in common use in industrial applications for many years and, as a result, are well understood. For these reasons, shell and tube heat exchangers will not be covered in this chapter.

  16. Higher Education Exchange, 2014

    Science.gov (United States)

    Brown, David W., Ed.; Witte, Deborah, Ed.

    2014-01-01

    Research shows that not only does higher education not see the public; when the public, in turn, looks at higher education, it sees mostly malaise, inefficiencies, expense, and unfulfilled promises. Yet, the contributors to this issue of the "Higher Education Exchange" tell of bright spots in higher education where experiments in working…

  17. Upright heat exchanger

    International Nuclear Information System (INIS)

    Martoch, J.; Kugler, V.; Krizek, V.; Strmiska, F.

    1988-01-01

    The claimed heat exchanger is characteristic by the condensate level being maintained directly in the exchanger while preserving the so-called ''dry'' tube plate. This makes it unnecessary to build another pressure vessel into the circuit. The design of the heat exchanger allows access to both tube plates, which facilitates any repair. Another advantage is the possibility of accelerating the indication of leakage from the space of the second operating medium which is given by opening the drainage pipes of the lower bundle into the collar space and from there through to the indication pipe. The exchanger is especially suitable for deployment in the circuits of nuclear power plants where the second operating medium will be hot water of considerably lower purity than is that of the condensate. A rapid display of leakage can prevent any long-term penetration of this water into the condensate, which would result in worsening water quality in the entire secondary circuit of the nuclear power plant. (J.B.). 1 fig

  18. Fuel exchanger control device

    International Nuclear Information System (INIS)

    Kurabayashi, Masaharu.

    1985-01-01

    Purpose: To improve the stability and the operationability of the fuel exchanging work by checking the validity of the data before the initiation of the work. Constitution: A floppy disc stores the initial charging state data showing the arrangement of fuel assemblies in the reactor core pool, data showing the working procedures for the fuel exchange and a final charged state data upon completion of the work. The initial data and the procedure data are read from the disk and stored once into a memory. Then, the initial data are sequentially performed on the memory in accordance with the procedure data and, thereafter, they were compared with the final data read from the disk. After confirming that there are no errors in the working data, the procedure data are orderly instructed to the fuel exchanger for performing fuel replacement. Accordingly, since the data are checked before the initiation of the work, the fuel exchange can be performed automatically thereby improving the operationability thereof. (Yoshino, Y.)

  19. Basic Exchange Rate Theories

    NARCIS (Netherlands)

    J.G.M. van Marrewijk (Charles)

    2005-01-01

    textabstractThis four-chapter overview of basic exchange rate theories discusses (i) the elasticity and absorption approach, (ii) the (long-run) implications of the monetary approach, (iii) the short-run effects of monetary and fiscal policy under various economic conditions, and (iv) the transition

  20. Telephone Exchange Maintenance

    CERN Multimedia

    2005-01-01

    Urgent maintenance work on CERN telephone exchanges will be performed on 24 March from 6 a.m. to 8 a.m. Telephone services may be disrupted or even interrupted during this time. For more details, please contact us by email at Standard.Telephone@cern.ch.

  1. Counterflow Regolith Heat Exchanger

    Science.gov (United States)

    Zubrin, Robert; Jonscher, Peter

    2013-01-01

    A problem exists in reducing the total heating power required to extract oxygen from lunar regolith. All such processes require heating a great deal of soil, and the heat energy is wasted if it cannot be recycled from processed material back into new material. The counterflow regolith heat exchanger (CoRHE) is a device that transfers heat from hot regolith to cold regolith. The CoRHE is essentially a tube-in-tube heat exchanger with internal and external augers attached to the inner rotating tube to move the regolith. Hot regolith in the outer tube is moved in one direction by a right-hand - ed auger, and the cool regolith in the inner tube is moved in the opposite direction by a left-handed auger attached to the inside of the rotating tube. In this counterflow arrangement, a large fraction of the heat from the expended regolith is transferred to the new regolith. The spent regolith leaves the heat exchanger close to the temperature of the cold new regolith, and the new regolith is pre-heated close to the initial temperature of the spent regolith. Using the CoRHE can reduce the heating requirement of a lunar ISRU system by 80%, reducing the total power consumption by a factor of two. The unique feature of this system is that it allows for counterflow heat exchange to occur between solids, instead of liquids or gases, as is commonly done. In addition, in variants of this concept, the hydrogen reduction can be made to occur within the counterflow heat exchanger itself, enabling a simplified lunar ISRU (in situ resource utilization) system with excellent energy economy and continuous nonbatch mode operation.

  2. 78 FR 49579 - Self-Regulatory Organizations; EDGX Exchange, Inc.; Notice of Filing and Immediate Effectiveness...

    Science.gov (United States)

    2013-08-14

    ... volume calculations for wholly owned affiliates on a prospective basis. Lastly, the section will clarify... that Direct Edge ECN LLC (d/b/a DE Route) (``DE Route''), the Exchange's affiliated routing broker...

  3. 78 FR 49588 - Self-Regulatory Organizations; EDGA Exchange, Inc.; Notice of Filing and Immediate Effectiveness...

    Science.gov (United States)

    2013-08-14

    ... request, EDGA will aggregate share volume calculations for wholly owned affiliates on a prospective basis... Route) (``DE Route''), the Exchange's affiliated routing broker-dealer, is charged for routing orders to...

  4. Thermodynamics of heat-and material-exchange in engineering

    Energy Technology Data Exchange (ETDEWEB)

    Matz, W.

    1944-05-23

    This book-length discussion of thermodynamics emphasized the situation of exchanges of heat and materials during various processes. Within the first chapter (on general foundations) the major headings were Points of view and means of representation, Conditions and characteristics of materials, The first law and energy, The second law and entropy, Equilibrium, and The general similarity-principle in heat-and material-exchange. The second chapter (on heat-and material-exchange in counterflow between two phases) had headings The harmonic triangle diagram, The heat exchanger, Heat exchange by means of procedures of blowing, Heating and cooling processes in vessels, Material exchange in couterflow, and Similarity among friction, heat-and material-exchange. The chapter on exchanges between vapor and liquid in single substances discussed evaporation processes and vapor-air mixtures. There were also chapters on exchanges during distillation, adsorption, absorption, and extraction. There was also an extensive bibliography and a collection of 107 diagrams of various types of representatives of thermodynamic relationships. (Some parts of the book appear out of order on the microfilm reels.) 107 diagrams.

  5. A corrosive resistant heat exchanger

    Science.gov (United States)

    Richlen, S.L.

    1987-08-10

    A corrosive and erosive resistant heat exchanger which recovers heat from a contaminated heat stream. The heat exchanger utilizes a boundary layer of innocuous gas, which is continuously replenished, to protect the heat exchanger surface from the hot contaminated gas. The innocuous gas is pumped through ducts or perforations in the heat exchanger wall. Heat from the heat stream is transferred by radiation to the heat exchanger wall. Heat is removed from the outer heat exchanger wall by a heat recovery medium. 3 figs., 3 tabs.

  6. Analytical applications of ion exchangers

    CERN Document Server

    Inczédy, J

    1966-01-01

    Analytical Applications of Ion Exchangers presents the laboratory use of ion-exchange resins. This book discusses the development in the analytical application of ion exchangers. Organized into 10 chapters, this book begins with an overview of the history and significance of ion exchangers for technical purposes. This text then describes the properties of ion exchangers, which are large molecular water-insoluble polyelectrolytes having a cross-linked structure that contains ionic groups. Other chapters consider the theories concerning the operation of ion-exchange resins and investigate th

  7. Electrochemical ion exchange of LOMI decontamination solutions

    International Nuclear Information System (INIS)

    Bradbury, D.; Elder, G.R.

    1991-05-01

    The objective of the LOMI Electrochemical Ion Exchange (ELOMIX) process is to reduce the volume of waste arising from LOMI decontamination operations. This is achieved by using the conventional ion exchange resin as an intermediate, rather than a final waste form. Radioactive and metal ion constitutents removed during the decontamination are converted by the process to a metallic form. In its simplest form the ELOMIX cell consists of three compartments, (anode, cathode and resin) separated by cation permeable membranes. In the resin compartment, radioactive and chemical components are removed from the flowing solution by the resin. These components are then migrated under the influence of an electric field into the cathode compartment where metallic elements are deposited. After successful laboratory testing a pilot scale ELOMIX unit was constructed and shipped to Commonwealth Edison's Dresden Unit 2 LOMI decontamination in October 1990. The pilot-scale cell was tied in to the decontamination equipment. The cell operated successfully during three LOMI steps, processing a total of 165 resin bed volumes of solution, far exceeding the normal capacity of the ion exchange resin. Removal efficiencies for iron and radioactivity were good throughout the test. The ELOMIX unit was successfully operated in the time, operational and safety constraints of a reactor decontamination. The main benefits of the process are reduced waste volume, and greater chemical and radiation stability of the waste, which is particularly relevant to full system decontamination. Although the testing to date has focused on the LOMI process, the ELOMIX technique could in principle be applied to be other decontamination processes. 13 figs., 1 tab

  8. Study of the operation temperature in the spin-exchange relaxation free magnetometer

    International Nuclear Information System (INIS)

    Fang, Jiancheng; Li, Rujie; Duan, Lihong; Chen, Yao; Quan, Wei

    2015-01-01

    We study the influence of the cell temperature on the sensitivity of the spin-exchange relaxation free (SERF) magnetometer and analyze the possibility of operating at a low temperature. Utilizing a 25 × 25 × 25 mm 3 Cs vapor cell with a heating temperature of 85  ∘ C, which is almost half of the value of potassium, we obtain a linewidth of 1.37 Hz and achieve a magnetic field sensitivity of 55 fT/Hz 1/2 in a single channel. Theoretical analysis shows that fundamental sensitivity limits of this device with an active volume of 1 cm 3 could approach 1 fT/Hz 1/2 . Taking advantage of the higher saturated vapor pressure, SERF magnetometer based on Cs opens up the possibility for low cost and portable sensors and is particularly appropriate for lower temperature applications

  9. Study of the operation temperature in the spin-exchange relaxation free magnetometer

    Energy Technology Data Exchange (ETDEWEB)

    Fang, Jiancheng; Li, Rujie, E-mail: lirujie@buaa.edu.cn; Duan, Lihong; Chen, Yao; Quan, Wei [School of Instrument Science and Opto-Electronics Engineering, Beihang University, Beijing 100191 (China)

    2015-07-15

    We study the influence of the cell temperature on the sensitivity of the spin-exchange relaxation free (SERF) magnetometer and analyze the possibility of operating at a low temperature. Utilizing a 25 × 25 × 25 mm{sup 3} Cs vapor cell with a heating temperature of 85 {sup ∘}C, which is almost half of the value of potassium, we obtain a linewidth of 1.37 Hz and achieve a magnetic field sensitivity of 55 fT/Hz{sup 1/2} in a single channel. Theoretical analysis shows that fundamental sensitivity limits of this device with an active volume of 1 cm{sup 3} could approach 1 fT/Hz{sup 1/2}. Taking advantage of the higher saturated vapor pressure, SERF magnetometer based on Cs opens up the possibility for low cost and portable sensors and is particularly appropriate for lower temperature applications.

  10. Foreign exchange rate entropy evolution during financial crises

    Science.gov (United States)

    Stosic, Darko; Stosic, Dusan; Ludermir, Teresa; de Oliveira, Wilson; Stosic, Tatijana

    2016-05-01

    This paper examines the effects of financial crises on foreign exchange (FX) markets, where entropy evolution is measured for different exchange rates, using the time-dependent block entropy method. Empirical results suggest that financial crises are associated with significant increase of exchange rate entropy, reflecting instability in FX market dynamics. In accordance with phenomenological expectations, it is found that FX markets with large liquidity and large trading volume are more inert - they recover quicker from a crisis than markets with small liquidity and small trading volume. Moreover, our numerical analysis shows that periods of economic uncertainty are preceded by periods of low entropy values, which may serve as a tool for anticipating the onset of financial crises.

  11. Secure Information Exchange Gateway for Electric Grid Operations

    Energy Technology Data Exchange (ETDEWEB)

    Robertson, F. Russell [Grid Protection Alliance, Chattanooga, TN (United States); Carroll, J. Ritchie [Grid Protection Alliance, Chattanooga, TN (United States); Sanders, William [Univ. of Illinois, Urbana-Champaign, IL (United States); Yardley, Timothy [Univ. of Illinois, Urbana-Champaign, IL (United States); Heine, Erich [Univ. of Illinois, Urbana-Champaign, IL (United States); Hadley, Mark [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); McKinnon, David [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Motteler, Barbara [Alstom Grid Inc., Levallois-Perret Cedex (France); Giri, Jay [Grid Protection Alliance, Chattanooga, TN (United States); Walker, William [PJM Interconnection (PJM), Norristown, PA (United States); McCartha, Esrick [PJM Interconnection (PJM), Norristown, PA (United States)

    2014-09-30

    The major objectives of the SIEGate project were to improve the security posture and minimize the cyber-attack surface of electric utility control centers and to reduce the cost of maintaining control-room-to-control-room information exchange. Major project goals included the design, development, testing, and commercialization of a single security-hardened appliance that could meet industry needs for resisting cyber-attacks while protecting the confidentiality and integrity of a growing volume of real-time information needed to ensure the reliability of the bulk electric system and interoperating with existing data formats and networking technologies. The SIEGate project has achieved its goals and objectives. The SIEGate Design Document, issued in March 2012, presented SIEGate use cases, provided SIEGate requirements, established SIEGate design principles, and prescribed design functionality of SIEGate as well as the components that make up SIEGate. SIEGate Release Version 1.0 was posted in January 2014. Release Version 1.0.83, which was posted on March 28, 2014, fixed many issues discovered by early adopters and added several new features. Release Candidate 1.1, which added additional improvements and bug fixes, was posted in June 2014. SIEGate executables have been downloaded more than 300 times. SIEGate has been tested at PJM, Entergy, TVA, and Southern. Security testing and analysis of SIEGate has been conducted at PNNL and PJM. Alstom has provided a summary of recommended steps for commercialization of the SIEGate Appliance and identified two deployment models with immediate commercial application.

  12. Computational fluid dynamics modeling of proton exchange membrane fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    UM,SUKKEE; WANG,C.Y.; CHEN,KEN S.

    2000-02-11

    A transient, multi-dimensional model has been developed to simulate proton exchange membrane (PEM) fuel cells. The model accounts simultaneously for electrochemical kinetics, current distribution, hydrodynamics and multi-component transport. A single set of conservation equations valid for flow channels, gas-diffusion electrodes, catalyst layers and the membrane region are developed and numerically solved using a finite-volume-based computational fluid dynamics (CFD) technique. The numerical model is validated against published experimental data with good agreement. Subsequently, the model is applied to explore hydrogen dilution effects in the anode feed. The predicted polarization cubes under hydrogen dilution conditions are found to be in qualitative agreement with recent experiments reported in the literature. The detailed two-dimensional electrochemical and flow/transport simulations further reveal that in the presence of hydrogen dilution in the fuel stream, hydrogen is depleted at the reaction surface resulting in substantial kinetic polarization and hence a lower current density that is limited by hydrogen transport from the fuel stream to the reaction site.

  13. The Metaphysics of Economic Exchanges

    Directory of Open Access Journals (Sweden)

    Massin Olivier

    2017-05-01

    Full Text Available What are economic exchanges? The received view has it that exchanges are mutual transfers of goods motivated by inverse valuations thereof. As a corollary, the standard approach treats exchanges of services as a subspecies of exchanges of goods. We raise two objections against this standard approach. First, it is incomplete, as it fails to take into account, among other things, the offers and acceptances that lie at the core of even the simplest cases of exchanges. Second, it ultimately fails to generalize to exchanges of services, in which neither inverse preferences nor mutual transfers hold true. We propose an alternative definition of exchanges, which treats exchanges of goods as a special case of exchanges of services and which builds in offers and acceptances. According to this theory: (i The valuations motivating exchanges are propositional and convergent rather than objectual and inverse; (ii All exchanges of goods involve exchanges of services/actions, but not the reverse; (iii Offers and acceptances, together with the contractual obligations and claims they bring about, lie at the heart of all cases of exchange.

  14. Myocardial serotonin exchange: negligible uptake by capillary endothelium

    International Nuclear Information System (INIS)

    Moffett, T.C.; Chan, I.S.; Bassingthwaighte, J.B.

    1988-01-01

    The extraction of serotonin from the blood during transorgan passage through the heart was studied using Langendorff-perfused rabbit hearts. Outflow dilution curves of 131 I- or 125 I-labeled albumin, [ 14 C]sucrose, and [3H]serotonin injected simultaneously into the inflow were fitted with an axially distributed blood-tissue exchange model to examine the extraction process. The model fits of the albumin and sucrose outflow dilution curves were used to define flow heterogeneity, intravascular dispersion, capillary permeability, and the volume of the interstitial space, which reduced the degrees of freedom in fitting the model to the serotonin curves. Serotonin extractions, measured against albumin, during single transcapillary passage, ranged from 24 to 64%. The ratio of the capillary permeability-surface area products for serotonin and sucrose, based on the maximum instantaneous extraction, was 1.37 +/- 0.2 (n = 18), very close to the predicted value of 1.39, the ratio of free diffusion coefficients calculated from the molecular weights. This result shows that the observed uptake of serotonin can be accounted for solely on the basis of diffusion between endothelial cells into the interstitial space. Thus it appears that the permeability of the luminal surface of the endothelial cell is negligible in comparison to diffusion through the clefts between endothelial cells. In 18 sets of dilution curves, with and without receptor and transport blockers or competitors (ketanserin, desipramine, imipramine, serotonin), the extractions and estimates of the capillary permeability-surface area product were not reduced, nor were the volumes of distribution. The apparent absence of transporters and receptors in rabbit myocardial capillary endothelium contrasts with their known abundance in the pulmonary vasculature

  15. Evaluating humidity recovery efficiency of currently available heat and moisture exchangers: a respiratory system model study

    Directory of Open Access Journals (Sweden)

    Jeanette Janaina Jaber Lucato

    2009-06-01

    Full Text Available OBJECTIVES: To evaluate and compare the efficiency of humidification in available heat and moisture exchanger models under conditions of varying tidal volume, respiratory rate, and flow rate. INTRODUCTION: Inspired gases are routinely preconditioned by heat and moisture exchangers to provide a heat and water content similar to that provided normally by the nose and upper airways. The absolute humidity of air retrieved from and returned to the ventilated patient is an important measurable outcome of the heat and moisture exchangers' humidifying performance. METHODS: Eight different heat and moisture exchangers were studied using a respiratory system analog. The system included a heated chamber (acrylic glass, maintained at 37°C, a preserved swine lung, a hygrometer, circuitry and a ventilator. Humidity and temperature levels were measured using eight distinct interposed heat and moisture exchangers given different tidal volumes, respiratory frequencies and flow-rate conditions. Recovery of absolute humidity (%RAH was calculated for each setting. RESULTS: Increasing tidal volumes led to a reduction in %RAH for all heat and moisture exchangers while no significant effect was demonstrated in the context of varying respiratory rate or inspiratory flow. CONCLUSIONS: Our data indicate that heat and moisture exchangers are more efficient when used with low tidal volume ventilation. The roles of flow and respiratory rate were of lesser importance, suggesting that their adjustment has a less significant effect on the performance of heat and moisture exchangers.

  16. Evaluating humidity recovery efficiency of currently available heat and moisture exchangers: a respiratory system model study.

    Science.gov (United States)

    Lucato, Jeanette Janaina Jaber; Adams, Alexander Bernard; Souza, Rogério; Torquato, Jamili Anbar; Carvalho, Carlos Roberto Ribeiro; Marini, John J

    2009-01-01

    To evaluate and compare the efficiency of humidification in available heat and moisture exchanger models under conditions of varying tidal volume, respiratory rate, and flow rate. Inspired gases are routinely preconditioned by heat and moisture exchangers to provide a heat and water content similar to that provided normally by the nose and upper airways. The absolute humidity of air retrieved from and returned to the ventilated patient is an important measurable outcome of the heat and moisture exchangers' humidifying performance. Eight different heat and moisture exchangers were studied using a respiratory system analog. The system included a heated chamber (acrylic glass, maintained at 37 degrees C), a preserved swine lung, a hygrometer, circuitry and a ventilator. Humidity and temperature levels were measured using eight distinct interposed heat and moisture exchangers given different tidal volumes, respiratory frequencies and flow-rate conditions. Recovery of absolute humidity (%RAH) was calculated for each setting. Increasing tidal volumes led to a reduction in %RAH for all heat and moisture exchangers while no significant effect was demonstrated in the context of varying respiratory rate or inspiratory flow. Our data indicate that heat and moisture exchangers are more efficient when used with low tidal volume ventilation. The roles of flow and respiratory rate were of lesser importance, suggesting that their adjustment has a less significant effect on the performance of heat and moisture exchangers.

  17. Depreciations without Exports? : Global Value Chains and the Exchange Rate Elasticity of Exports

    OpenAIRE

    Ahmed, Swarnali; Ruta, Michele; Appendino, Maximiliano

    2015-01-01

    This paper analyzes how the exchange rate elasticity of exports has changed over time and across countries and sectors, and how the formation of global value chains has affected this relationship. The analysis uses a panel framework covering 46 countries over the period 1996-2012, and first finds evidence that the elasticity of manufacturing export volumes to the real effective exchange ra...

  18. 78 FR 58354 - Self-Regulatory Organizations; Chicago Board Options Exchange, Incorporated; Notice of Filing and...

    Science.gov (United States)

    2013-09-23

    ... AA classes based on several factors, including competitive forces and trading volume.\\3\\ The Exchange... electronically in additional Hybrid option classes. The Exchange believes this may result in more competitive pricing in IWM and other Hybrid option classes, which will promote just and equitable principles of trade...

  19. 77 FR 23307 - Self-Regulatory Organizations; BATS Exchange, Inc.; Notice of Filing and Immediate Effectiveness...

    Science.gov (United States)

    2012-04-18

    ... a Member's growth patterns. Such increased volume increases potential revenue to the Exchange, and... by the Exchange. The increased liquidity also benefits all investors by deepening the BATS Options liquidity pool, offering additional flexibility for all investors to enjoy cost savings, supporting the...

  20. 77 FR 2108 - Self-Regulatory Organizations; BATS Exchange, Inc.; Notice of Filing and Immediate Effectiveness...

    Science.gov (United States)

    2012-01-13

    ...'s growth patterns. Such increased volume increases potential revenue to the Exchange, and will allow... Exchange. The increased liquidity also benefits all investors by deepening the BATS Options liquidity pool, offering additional flexibility for all investors to enjoy cost savings, supporting the quality of price...

  1. The Advantage of Hiding Both Hands : Foreign Exchange Intervention, Ambiguity and Private Information

    NARCIS (Netherlands)

    Eijffinger, S.C.W.; Verhagen, W.H.

    1997-01-01

    This paper analyzes a dynamic exchange rate policy game in which the central bank has private information about its short-term exchange rate target, on the one hand, and in which the market is faced with a certain degree of ambiguity concerning the actual intervention volume, on the other.

  2. 77 FR 67847 - Self-Regulatory Organizations; Chicago Board Options Exchange, Incorporated; Notice of Filing and...

    Science.gov (United States)

    2012-11-14

    ... ex-dividend.\\5\\ Dividend strategy transactions are only executed by Market-Makers. The Exchange... Sliding Scale volume thresholds. However, because only Market- Makers execute dividend strategy trades and... from the list of strategy executions for which fee caps apply. Under the Exchange's current Fees...

  3. Data Exchange Inventory (DEXI) System

    Data.gov (United States)

    Social Security Administration — DEXI is an intranet application used by SSA users to track all incoming and outgoing data exchanges between SSA and our data exchange partners. Information such as...

  4. Compact cryocooler heat exchangers

    International Nuclear Information System (INIS)

    Luna, J.; Frederking, T.H.K.

    1991-01-01

    Compact heat exchangers are subject to different constraints as a room temperature gas is cooled down by a cold stream returning from a JT valve (or a similar cryoprocess component). In particular, the optimization of exchangers for liquid helium systems has to cover a wide range in temperature and density of the fluid. In the present work we address the following thermodynamic questions: 1. The optimization of intermediate temperatures which optimize stage operation (a stage is assumed to have a constant cross section); 2. The optimum temperature difference available for best overall economic performance values. The results are viewed in the context of porous media concepts applied to rather low speeds of fluid flow in narrow passages. In this paper examples of fluid/solid constraints imposed in this non-classical low temperature area are presented

  5. Lipid exchange by ultracentrifugation

    DEFF Research Database (Denmark)

    Drachmann, Nikolaj Düring; Olesen, Claus

    2014-01-01

    Lipids play an important role in maintaining P-type ATPase structure and function, and often they are crucial for ATPase activity. When the P-type ATPases are in the membrane, they are surrounded by a mix of different lipids species with varying aliphatic chain lengths and saturation......, and the complex interplay between the lipids and the P-type ATPases are still not well understood. We here describe a robust method to exchange the majority of the lipids surrounding the ATPase after solubilisation and/or purification with a target lipid of interest. The method is based on an ultracentrifugation...... step, where the protein sample is spun through a dense buffer containing large excess of the target lipid, which results in an approximately 80-85 % lipid exchange. The method is a very gently technique that maintains protein folding during the process, hence allowing further characterization...

  6. Heat exchanger tube mounts

    Science.gov (United States)

    Wolowodiuk, W.; Anelli, J.; Dawson, B.E.

    1974-01-01

    A heat exchanger in which tubes are secured to a tube sheet by internal bore welding is described. The tubes may be moved into place in preparation for welding with comparatively little trouble. A number of segmented tube support plates are provided which allow a considerable portion of each of the tubes to be moved laterally after the end thereof has been positioned in preparation for internal bore welding to the tube sheet. (auth)

  7. Organ volume estimation using SPECT

    CERN Document Server

    Zaidi, H

    1996-01-01

    Knowledge of in vivo thyroid volume has both diagnostic and therapeutic importance and could lead to a more precise quantification of absolute activity contained in the thyroid gland. In order to improve single-photon emission computed tomography (SPECT) quantitation, attenuation correction was performed according to Chang's algorithm. The dual-window method was used for scatter subtraction. We used a Monte Carlo simulation of the SPECT system to accurately determine the scatter multiplier factor k. Volume estimation using SPECT was performed by summing up the volume elements (voxels) lying within the contour of the object, determined by a fixed threshold and the gray level histogram (GLH) method. Thyroid phantom and patient studies were performed and the influence of 1) fixed thresholding, 2) automatic thresholding, 3) attenuation, 4) scatter, and 5) reconstruction filter were investigated. This study shows that accurate volume estimation of the thyroid gland is feasible when accurate corrections are perform...

  8. Exchange rate rebounds after foreign exchange market interventions

    Science.gov (United States)

    Hoshikawa, Takeshi

    2017-03-01

    This study examined the rebounds in the exchange rate after foreign exchange intervention. When intervention is strongly effective, the exchange rate rebounds at next day. The effect of intervention is reduced slightly by the rebound after the intervention. The exchange rate might have been 67.12-77.47 yen to a US dollar without yen-selling/dollar-purchasing intervention of 74,691,100 million yen implemented by the Japanese government since 1991, in comparison to the actual exchange rate was 103.19 yen to the US dollar at the end of March 2014.

  9. Oscillating side-branch enhancements of thermoacoustic heat exchangers

    Science.gov (United States)

    Swift, Gregory W.

    2003-05-13

    A regenerator-based engine or refrigerator has a regenerator with two ends at two different temperatures, through which a gas oscillates at a first oscillating volumetric flow rate in the direction between the two ends and in which the pressure of the gas oscillates, and first and second heat exchangers, each of which is at one of the two different temperatures. A dead-end side branch into which the gas oscillates has compliance and is connected adjacent to one of the ends of the regenerator to form a second oscillating gas flow rate additive with the first oscillating volumetric flow rate, the compliance having a volume effective to provide a selected total oscillating gas volumetric flow rate through the first heat exchanger. This configuration enables the first heat exchanger to be configured and located to better enhance the performance of the heat exchanger rather than being confined to the location and configuration of the regenerator.

  10. Optimized Configuration and Operation of CVCS Ion Exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Park, Byeong Ho; Ko, Yong Sang; Kim, Do Hyun; Lee, Sang Seob; Chung, Chang Kyu [Korea Power Engineering Company, Inc., Daejeon (Korea, Republic of)

    2007-10-15

    Control of PWR primary water chemistry is essential to guarantee fuel and materials integrity and to maintain plant radiation fields as low as reasonably achievable. All PWRs have at least two ion exchangers in the Chemical and Volume Control System (CVCS) for chemical impurity control and radionuclide removal. Some nuclear power plants have several ion exchangers which can be operated in parallel. In order to remove boron near the end of a reactor core cycle some plants use separate anion beds downstream of the normal purification. The difference in design and operating philosophy has produced several practices for the ion exchanger operations in the CVCS. The purpose of this paper is to suggest an optimized configuration of ion exchangers for dealing with the resin usage and the liquid waste.

  11. Study on actinoid isolation by antimonide ion exchanger

    Energy Technology Data Exchange (ETDEWEB)

    Tsuji, Masamichi [Tokyo Inst. of Tech. (Japan). Faculty of Science; Kubota, Masumitsu; Yamagishi, Isao

    1996-01-01

    To establish a containment of long-life nuclides and an effective reduction of waste volume is important to reduce the loadings on the natural environment. Chemical isolation of radioactive nuclides from wastes was attempted by using inorganic ion exchanger with high specificity and thermal stability. In this study, titanium antimonide was used as an ion exchanger to investigate the adsorption of trivalent metallic ions according to Kielland plot curves. When the ionic equivalent fraction (X-bar{sub M}) was around 0.005, Kielland plot curve of either of 3-valent metallic ions was bent, suggesting the exchanger had two different adsorption sites. The slope of the curve became smaller as an elevation of temperature. These results show that the ion radius was decreased resulting from partial elimination of the hydrated water of ion and thus, the steric conditions around the exchange site might be improved. (M.N.)

  12. Scraped surface heat exchangers.

    Science.gov (United States)

    Rao, Chetan S; Hartel, Richard W

    2006-01-01

    Scraped surface heat exchangers (SSHEs) are commonly used in the food, chemical, and pharmaceutical industries for heat transfer, crystallization, and other continuous processes. They are ideally suited for products that are viscous, sticky, that contain particulate matter, or that need some degree of crystallization. Since these characteristics describe a vast majority of processed foods, SSHEs are especially suited for pumpable food products. During operation, the product is brought in contact with a heat transfer surface that is rapidly and continuously scraped, thereby exposing the surface to the passage of untreated product. In addition to maintaining high and uniform heat exchange, the scraper blades also provide simultaneous mixing and agitation. Heat exchange for sticky and viscous foods such as heavy salad dressings, margarine, chocolate, peanut butter, fondant, ice cream, and shortenings is possible only by using SSHEs. High heat transfer coefficients are achieved because the boundary layer is continuously replaced by fresh material. Moreover, the product is in contact with the heating surface for only a few seconds and high temperature gradients can be used without the danger of causing undesirable reactions. SSHEs are versatile in the use of heat transfer medium and the various unit operations that can be carried out simultaneously. This article critically reviews the current understanding of the operations and applications of SSHEs.

  13. Hydrogen isotope exchange reactions

    International Nuclear Information System (INIS)

    Jones, J.R.

    1980-01-01

    The two most widely used methods for following hydrogen isotope exchange reactions, namely dedeuteriation and detritiation, involve in the first place the synthesis of an appropriately labelled compound. Rates of dedeuteriation are usually followed by measuring changes in the 1 H n.m.r. spectrum of the substrate (examples are given); the method not only gives the rate but also the site(s) of exchange. It is limited to rather slow reactions and is not as accurate as some of the other methods. The development of deuterium n.m.r. spectroscopy means that changes in the 2 H n.m.r. spectrum can also be used to measure rates of dedeuteriation. The development of liquid scintillation counting greatly eased the problem of how to detect weak β emitters; the attractions of tritium as a tracer were thereby much enhanced. Nowadays the study of rates of detritiation constitutes one of the most versatile and accurate methods of following hydrogen isotope exchange. Examples of the technique are given. (U.K.)

  14. Paste heat exchange

    Energy Technology Data Exchange (ETDEWEB)

    1943-07-30

    The subject of coal paste heat exchangers is discussed in this letter report from Gelsenberg A.G. to I.G. Farbenindustrie A.G. Gelsenberg had given little consideration to the heating of coal paste by means of regeneration (heat exchange) because of the lack of experience in paste regeneration with bituminous coal, especially at 700 atmospheres. At the I.G. Farben plant at Poelitz, paste regeneration was carried out so that low concentration coal paste was heated in the regenerator together with the process gas, and the remaining coal was fed into the cold pass of the preheater in a thicker paste. Later tests proved this process viable. Gelsenberg heated normal coal paste and the gas in heat exchangers with the goal of relieving the preheater. Good results were achieved without change in design. The coal paste was heated with process gas in the regenerator at up to 315 degrees with constant pressure difference, so that after three months no decrease in K-values and no deposition or thickening was observed. Through the omission of paste gas, the pressure difference of the system became more constant and did not rise above the former level. The temperature also was more controllable, the chamber smoother running. Principal thermal data are given in a table. 1 table, 1 graph.

  15. Timing Foreign Exchange Markets

    Directory of Open Access Journals (Sweden)

    Samuel W. Malone

    2016-03-01

    Full Text Available To improve short-horizon exchange rate forecasts, we employ foreign exchange market risk factors as fundamentals, and Bayesian treed Gaussian process (BTGP models to handle non-linear, time-varying relationships between these fundamentals and exchange rates. Forecasts from the BTGP model conditional on the carry and dollar factors dominate random walk forecasts on accuracy and economic criteria in the Meese-Rogoff setting. Superior market timing ability for large moves, more than directional accuracy, drives the BTGP’s success. We explain how, through a model averaging Monte Carlo scheme, the BTGP is able to simultaneously exploit smoothness and rough breaks in between-variable dynamics. Either feature in isolation is unable to consistently outperform benchmarks throughout the full span of time in our forecasting exercises. Trading strategies based on ex ante BTGP forecasts deliver the highest out-of-sample risk-adjusted returns for the median currency, as well as for both predictable, traded risk factors.

  16. Heat exchanger for fuel cell power plant reformer

    Science.gov (United States)

    Misage, Robert; Scheffler, Glenn W.; Setzer, Herbert J.; Margiott, Paul R.; Parenti, Jr., Edmund K.

    1988-01-01

    A heat exchanger uses the heat from processed fuel gas from a reformer for a fuel cell to superheat steam, to preheat raw fuel prior to entering the reformer and to heat a water-steam coolant mixture from the fuel cells. The processed fuel gas temperature is thus lowered to a level useful in the fuel cell reaction. The four temperature adjustments are accomplished in a single heat exchanger with only three heat transfer cores. The heat exchanger is preheated by circulating coolant and purge steam from the power section during startup of the latter.

  17. Study of transient behavior of finned coil heat exchangers

    Science.gov (United States)

    Rooke, S. P.; Elissa, M. G.

    1993-01-01

    The status of research on the transient behavior of finned coil cross-flow heat exchangers using single phase fluids is reviewed. Applications with available analytical or numerical solutions are discussed. Investigation of water-to-air type cross-flow finned tube heat exchangers is examined through the use of simplified governing equations and an up-wind finite difference scheme. The degenerate case of zero air-side capacitance rate is compared with available exact solution. Generalization of the numerical model is discussed for application to multi-row multi-circuit heat exchangers.

  18. Excluded Volume Effects in Gene Stretching

    OpenAIRE

    Lam, Pui-Man

    2002-01-01

    We investigate the effects excluded volume on the stretching of a single DNA in solution. We find that for small force F, the extension h is not linear in F but proportion to F^{\\chi}, with \\chi=(1-\

  19. Spectrum '86: Proceedings: Volume 1

    International Nuclear Information System (INIS)

    Pope, J.M.; Leonard, I.M.; Mayer, E.J.

    1987-07-01

    This document, Volume 1 of two, contains 100 papers on various aspects of Radioactive Waste Management. Session topics include: nuclear success stories; low-level waste-grout; filtration and ion exchange, qualification, and pretreatment; solid waste treatment/endash/special grouts, and incineration; equipment design/endash/remote technology, and special equipment; high-level waste/endash/international vitrification projects, plans and system testing, product performance, meltor and product testing, off-gas behavior and processing. Individual reports were processed separately for the data bases

  20. Accuracy enhancement of magnetic field distribution measurements within a large cell spin-exchange relaxation-free magnetometer

    Science.gov (United States)

    Gusarov, Alexander; Ben-Amar Baranga, Andrei; Levron, David; Shuker, Reuben

    2018-04-01

    The factorial design technique is implemented to achieve greater accuracy in the determination of magnetic field distribution within a single cell of spin-exchange relaxation-free atomic magnetometer. Three-dimensional magnetic field distribution within a single vapor cell can be found by consecutively pumping, layer by layer, all the cell volumes perpendicular to the probe laser beam, detected by a photodiode array. Thus each element of the array collects information about the magnetic field in the small volume (voxel) which forms when the corresponding part of the probe beam and optically pumped layer cross. One of the most effective ways to enhance measurement accuracy is repeated pumping of the layers and averaging the measured results. However, the measurement time is multiplied several times due to the repeated scanning of the cell volume. The suggested technique enables increased measurement accuracy of each voxel while preserving the number of measurements. Magnetic field distribution is determined by the illumination of the cell layers one by one or simultaneously, according to a special algorithm, with subsequent multifactorial analysis of the obtained results.

  1. Ex vivo assessment and validation of water exchange performance of 23 heat and moisture exchangers for laryngectomized patients.

    Science.gov (United States)

    van den Boer, Cindy; Muller, Sara H; Vincent, Andrew D; van den Brekel, Michiel W M; Hilgers, Frans J M

    2014-08-01

    Breathing through a tracheostoma results in insufficient warming and humidification of the inspired air. This loss of air conditioning, especially humidification, can be partially restored with the application of a heat and moisture exchanger (HME) over the tracheostoma. For medical professionals, it is not easy to judge differences in water exchange performance of various HMEs owing to the lack of universal outcome measures. This study has three aims: assessment of the water exchange performance of commercially available HMEs for laryngectomized patients, validation of these results with absolute humidity outcomes, and assessment of the role of hygroscopic salt present in some of the tested HMEs. Measurements of weight and absolute humidity at end inspiration and end expiration at different breathing volumes of a healthy volunteer were performed using a microbalance and humidity sensor. Twenty-three HMEs from 6 different manufacturers were tested. Associations were determined between core weight, weight change, breathing volume, and absolute humidity, using both linear and nonlinear mixed effects models. Water exchange of the 23 HMEs at a breathing volume of 0.5 L varies between 0.5 and 3.6 mg. Both water exchange and wet core weight correlate strongly with the end-inspiratory absolute humidity values (r2 =0.89/0.87). Hygroscopic salt increases core weight. The 23 tested HMEs for laryngectomized patients show wide variation in water exchange performance. Water exchange correlates well with the end-inspiratory absolute humidity outcome, which validates the ex vivo weight change method. Wet core weight is a predictor of HME performance. Hygroscopic salt increases the weight of the core material. The results of this study can help medical professionals to obtain a more founded opinion about the performance of available HMEs for pulmonary rehabilitation in laryngectomized patients, and allow them to make an informed decision about which HME type to use.

  2. Sparse graphs using exchangeable random measures.

    Science.gov (United States)

    Caron, François; Fox, Emily B

    2017-11-01

    Statistical network modelling has focused on representing the graph as a discrete structure, namely the adjacency matrix. When assuming exchangeability of this array-which can aid in modelling, computations and theoretical analysis-the Aldous-Hoover theorem informs us that the graph is necessarily either dense or empty. We instead consider representing the graph as an exchangeable random measure and appeal to the Kallenberg representation theorem for this object. We explore using completely random measures (CRMs) to define the exchangeable random measure, and we show how our CRM construction enables us to achieve sparse graphs while maintaining the attractive properties of exchangeability. We relate the sparsity of the graph to the Lévy measure defining the CRM. For a specific choice of CRM, our graphs can be tuned from dense to sparse on the basis of a single parameter. We present a scalable Hamiltonian Monte Carlo algorithm for posterior inference, which we use to analyse network properties in a range of real data sets, including networks with hundreds of thousands of nodes and millions of edges.

  3. Integrated Foreign Exchange Risk Management

    DEFF Research Database (Denmark)

    Aabo, Tom; Høg, Esben; Kuhn, Jochen

    Empirical research has focused on export as a proxy for the exchange rate exposure and the use of foreign exchange derivatives as the instrument to deal with this exposure. This empirical study applies an integrated foreign exchange risk management approach with a particular focus on the role...... of import in medium-sized, manufacturing firms in Denmark (a small, open economy). We find a strong, negative relation between import and foreign exchange derivatives usage on the aggregate level. Our findings are consistent with the notion that firms use import to match the foreign exchange exposure...

  4. Integrated foreign exchange risk management

    DEFF Research Database (Denmark)

    Aabo, Tom; Høg, Esben; Kuhn, Jochen

    2010-01-01

    Empirical research has focused on export as a proxy for exchange rate exposure and the use of foreign exchange derivatives as an instrument to deal with this exposure. This empirical study applies an integrated foreign exchange risk management approach with a particular focus on the role of import...... in medium-sized manufacturing firms in Denmark (a small, open economy). We find a strong, negative relation between import and the use of foreign exchange derivatives on the aggregate level. Our findings are consistent with the notion that firms use import to match the foreign exchange exposure created...

  5. Mastering Microsoft Exchange Server 2010

    CERN Document Server

    McBee, Jim

    2010-01-01

    A top-selling guide to Exchange Server-now fully updated for Exchange Server 2010. Keep your Microsoft messaging system up to date and protected with the very newest version, Exchange Server 2010, and this comprehensive guide. Whether you're upgrading from Exchange Server 2007 SP1 or earlier, installing for the first time, or migrating from another system, this step-by-step guide provides the hands-on instruction, practical application, and real-world advice you need.: Explains Microsoft Exchange Server 2010, the latest release of Microsoft's messaging system that protects against spam and vir

  6. High-Frequency Jet Ventilation for Complete Target Immobilization and Reduction of Planning Target Volume in Stereotactic High Single-Dose Irradiation of Stage I Non-Small Cell Lung Cancer and Lung Metastases

    International Nuclear Information System (INIS)

    Fritz, Peter; Kraus, Hans-Joerg; Muehlnickel, Werner; Sassmann, Volker; Hering, Werner; Strauch, Konstantin

    2010-01-01

    Purpose: To demonstrate the feasibility of complete target immobilization by means of high-frequency jet ventilation (HFJV); and to show that the saving of planning target volume (PTV) on the stereotactic body radiation therapy (SBRT) under HFJV, compared with SBRT with respiratory motion, can be predicted with reliable accuracy by computed tomography (CT) scans at peak inspiration phase. Methods and Materials: A comparison regarding different methods for defining the PTV was carried out in 22 patients with tumors that clearly moved with respiration. A movement span of the gross tumor volume (GTV) was defined by fusing respiration-correlated CT scans. The PTV enclosed the GTV positions with a safety margin throughout the breathing cycle. To create a PTV from CT scans acquired under HFJV, the same margins were drawn around the immobilized target. In addition, peak inspiration phase CT images (PIP-CTs) were used to approximate a target immobilized by HFJV. Results: The resulting HFJV-PTVs were between 11.6% and 45.4% smaller than the baseline values calculated as respiration-correlated CT-PTVs (median volume reduction, 25.4%). Tentative planning by means of PIP-CT PTVs predicted that in 19 of 22 patients, use of HFJV would lead to a reduction in volume of ≥20%. Using this threshold yielded a positive predictive value of 0.89, as well as a sensitivity of 0.94 and a specificity of 0.5. Conclusions: In all patients, SBRT under HFJV provided a reliable immobilization of the GTVs and achieved a reduction in PTVs, regardless of patient compliance. Tentative planning facilitated the selection of patients who could better undergo radiation in respiratory standstill, both with greater accuracy and lung protection.

  7. Progress in liquid ion exchangers

    International Nuclear Information System (INIS)

    Nakagawa, Genkichi

    1974-01-01

    Review is made on the extraction with anion exchangers and the extraction with liquid cation exchangers. On the former, explanation is made on the extraction of acids, the relation between anion exchange and the extraction of metals, the composition of the metallic complexes that are extracted, and the application of the extraction with anion exchangers to analytical chemistry. On the latter, explanation is made on the extraction of metals and its application to analytical chemistry. The extraction with liquid ion exchangers is suitable for the operation in chromatography, because the distribution of extracting agents into aqueous phase is small, and extraction equilibrium is quickly reached, usually within 1 to several minutes. The separation by means of anion exchangers is usually made from hydrochloric acid solution. For example, Brinkman et al. determined Rf values for more than 50 elements by thin layer chromatography. Tables are given for showing the structure of the liquid ion exchangers and the polymerized state of various amines. (Mori, K.)

  8. 35Cl- and 2H NMR measurement of intracellular water volume in renal proximal tubules

    International Nuclear Information System (INIS)

    Hoffman, D.; Kumar, A.M.; Spitzer, A.; Gupta, R.K.

    1986-01-01

    Knowledge of cell water volume is essential for the calculation of concentrations of intracellular ions and metabolites in kidney tubules. The authors have developed a method which utilizes 35 Cl - NMR as a measure of extracellular volume and 2 H NMR in combination with a membrane-impermeant shift reagent Dy(DTPA) as a measure of the ratio of intra- and extracellular water volumes. Measurement of extracellular volume by 35 Cl - NMR is possible since intracellular 35 Cl - resonance is broadened beyond detection in most cells. The 2 H NMR measurements exploit the fact that only extracellular water is in direct contact with Dy(DTPA). However, rapid exchange of water across the cell membrane results in only a single 2 H 2 O resonance at a chemical shift which is a weighted average of the shifted extra- and unshifted intracellular water resonances. Denoting the extracellular volume as a fraction of the total volume by S/sub o/, and as a fraction of the total water volume by H/sub o/, the fractional cell water content, W = [(1/H/sub o/) -1]/[(1/S/sub o/)-1], can be calculated. Rat proximal tubule suspensions were prepared by the method developed in their laboratory. The water content was found to be 76.9 +/- 5% (anti +/- x SD, n = 4) at room temperature and 78.6% at 37 0 C. Increasing extracellular osmolality from 295 to 330 mosm/kg, by addition of mannitol, decreased the water content to 70.8%. The authors results are in good agreement with the previously reported values of 69-82%, obtained by other methods. Thus, NMR is an accurate, noninvasive method for measuring the water content of renal cells

  9. Intermediate heat exchanger project for Super Phenix

    International Nuclear Information System (INIS)

    Roumailhac, J.; Desir, D.

    1975-01-01

    The Super Phenix (1200 MWe) intermediate heat exchangers are derived directly from those of Phenix (250 MWe). The intermediate exchangers are housed in the reactor vessel annulus: as this annulus must be of the smallest volume possible, these IHX are required to work at a high specific rating. The exchange surface is calculated for nominal conditions. A range is then defined, consistent with the above requirements and throughout which the ratio between bundle thickness and bundle length remains acceptable. Experimental technics and calculations were used to determine the number of tube constraint systems required to keep the vibration amplitude within permissible limits. From a knowledge of this number, the pressure drop produced by the primary flow can be calculated. The bundle geometry is determined together with the design of the corresponding tube plates and the way in which these plates should be joined to the body of the IHX. The experience (technical and financial) acquired in the construction of Phenix is then used to optimize the design of the Super Phenix project. An approximate definition of the structure of the IHX is obtained by assuming a simplified load distribution in the calculations. More sophisticated calculations (e.g. finite element method) are then used to determine the behaviour of the different points of the IHX, under nominal and transient conditions

  10. π--induced single charge exchange on polarized 3He

    International Nuclear Information System (INIS)

    Zhao, Q.; Burleson, S.; Blanchard, T.

    1995-01-01

    Asymmetries, A y , for the (π - ,π 0 ) reaction on polarized 3 He were measured using the pion beam of the P3W channel at LAMPF. The π 0 were detected with the new Neutral Meson Spectrometer (NMS) in coincidence with recoiling tritons. The recoil detector consisted of scintillation-counter telescopes and a wire chamber that provided energy-loss and direction information, respectively. The polarized gaseous 3 He target developed at TRIUMF was modified and run with the use of two diode lasers. Polarizations were typically 50%. The A y taken at T π = 200 MeV between 60 and 105 degrees were found to be strongly angle-dependent. The results will be compared with the theoretical predictions

  11. Application of metal foam heat exchangers for a high-performance liquefied natural gas regasification system

    International Nuclear Information System (INIS)

    Kim, Dae Yeon; Sung, Tae Hong; Kim, Kyung Chun

    2016-01-01

    The intermediate fluid vaporizer has wide applications in the regasification of LNG (liquefied natural gas). The heat exchanger performance is one of the main contributors to the thermodynamic and cost effectiveness of the entire LNG regasification system. Within the paper, the authors discuss a new concept for a compact heat exchanger with a micro-cellular structure medium to minimize volume and mass and to increase thermal efficiency. Numerical calculations have been conducted to design a metal-foam filled plate heat exchanger and a shell-and-tube heat exchanger using published experimental correlations. The geometry of both heat exchangers was optimized using the conditions of thermolators in LNG regasification systems. The heat transfer and pressure drop performance was predicted to compare the heat exchangers. The results show that the metal-foam plate heat exchanger has the best performance at different channel heights and mass flow rates of fluid. In the optimized configurations, the metal-foam plate heat exchanger has a higher heat transfer rate and lower pressure drop than the shell-and-tube heat exchanger as the mass flow rate of natural gas is increased. - Highlights: • A metal foam heat exchanger is proposed for LNG regasification system. • Comparison was made with a shell and tube heat exchanger. • Heat transfer and pressure drop characteristics were estimated. • The geometry of both heat exchangers is optimized for thermolators. • It can be used as a compact and high performance thermolators.

  12. Cationic mobility in polystyrene sulfone exchangers - Application to the elution of a cation on an exchange column

    International Nuclear Information System (INIS)

    Menin, Jean-Pierre

    1969-01-01

    The aim of this work is to improve elutions and separations carried out on inorganic exchangers by selective electromigration of the ionic species to be displaced. To do this, it has been found indispensable to make a fundamental study of the mobility of cations in exchangers. As the field for this research we have chosen those organic exchangers whose structure and behaviour with respect to ion-exchange are much better known that in the case of their inorganic equivalents. We have related the idea of the equivalent conductivity to that of the cation mobility in the exchanger, and this has entailed determining the specific conductivity of the exchanger and the cation concentration in the resin. The results obtained have allowed us to draw up a hypothesis concerning the cation migration mechanism in the exchanger. The third part of our work has been the application of the preceding results to an operation on an ion-exchange column, viz. the elution by an acid solution of a single fixed ion, magnesium or strontium. This work has enabled us to show that the electromigration of a cation during its elution can markedly accelerate or retard this elution. (author) [fr

  13. Ion exchange and protonation equilibria of an amphoteric ion-exchange resin in the presence of simple salt.

    Science.gov (United States)

    Miyazaki, Yoshinobu; Qu, Hui; Konaka, Junko

    2008-09-01

    The influence of simple salts on the ion exchange and protonation equilibria of an amphoteric ion-exchange resin, which has strong base and weak acid moieties in a single functional group fixed onto the styrene-DVB matrix, has been investigated. Concentrations of ionic species in the amphoteric ion-exchange resin in equilibrium with various sodium salt solutions were estimated by (23)Na NMR spectroscopy. For the NaClO(4) system, the ratio of sodium ion concentration in the resin phase to that in the equilibrium solution was greater than 1 and increased with a decrease in the salt concentration. In contrast to an ordinary cation-exchange resin, the ion exchange behavior of Mg(2+) and Ca(2+) on the amphoteric ion-exchange resin showed a marked dependence on the kinds of salts: the distribution coefficients for the NaCl system were independent of the salt concentration, while the log D vs. log[Na(+)] plots for the NaClO(4) system showed linear relationships with slopes being neither -2 nor 0. Apparent protonation constants of the carboxylate in the functional group of the resin in equilibrium with NaClO(4) solutions were greater than those with NaCl solutions. The ion exchange and protonation properties of the amphoteric ion-exchange resin were elucidated on the basis of the information about the salt concentrations in the resin phase estimated by the NMR method.

  14. Meson exchange and neutral weak currents

    Energy Technology Data Exchange (ETDEWEB)

    Beck, D.H. [Univ. of Illinois, Urbana, IL (United States)

    1994-04-01

    Measurements of parity-violating electron scattering asymmetries to determine weak neutral currents in nuclei will be effected by the presence of meson exchange currents. Present low momentum transfer calculations, based on a flavor independent framework, show these effects to be small. In general, however, as the momentum transfer increases to values typical of deep-inelastic scattering, fragmentation functions show a clear flavor dependence. It is suggested that a good experimental starting point for understanding the flavor dependence of meson production and exchange currents is the Q{sup 2} dependence of parity-violating asymmetry in inclusive single pion electroproduction. A CEBAF facility with doubled energy is necessary to approach momentum transfers where this process begins to scale.

  15. Cryogenic regenerative heat exchangers

    CERN Document Server

    Ackermann, Robert A

    1997-01-01

    An in-depth survey of regenerative heat exchangers, this book chronicles the development and recent commercialization of regenerative devices for cryogenic applications. Chapters cover historical background, concepts, practical applications, design data, and numerical solutions, providing the latest information for engineers to develop advanced cryogenic machines. The discussions include insights into the operation of a regenerator; descriptions of the cyclic and fluid temperature distributions in a regenerator; data for various matrix geometries and materials, including coarse and fine bronze, stainless steel-woven wire mesh screens, and lead spheres; and unique operating features of cryocoolers that produce deviations from ideal regenerator theory.

  16. 77 FR 35735 - Self-Regulatory Organizations; BATS Exchange, Inc.; Notice of Filing and Immediate Effectiveness...

    Science.gov (United States)

    2012-06-14

    ... reasonable in that it rewards a Member's growth patterns. Such increased volume increases potential revenue..., such as higher levels of liquidity provision and/or growth patterns, and introduction of higher volumes... incentive programs operated by the Exchange. The increased liquidity also benefits all investors by...

  17. 77 FR 56896 - Self-Regulatory Organizations; EDGA Exchange, Inc.; Notice of Filing and Immediate Effectiveness...

    Science.gov (United States)

    2012-09-14

    ... PA is consistent with the Exchange's overall pricing philosophy of encouraging displayed liquidity... activity, such as higher levels of liquidity provision and introduction of higher volumes of orders into... market activity, such as higher levels of liquidity provision and introduction of higher volumes of...

  18. Heat exchanger-accumulator

    Science.gov (United States)

    Ecker, Amir L.

    1980-01-01

    What is disclosed is a heat exchanger-accumulator for vaporizing a refrigerant or the like, characterized by an upright pressure vessel having a top, bottom and side walls; an inlet conduit eccentrically and sealingly penetrating through the top; a tubular overflow chamber disposed within the vessel and sealingly connected with the bottom so as to define an annular outer volumetric chamber for receiving refrigerant; a heat transfer coil disposed in the outer volumetric chamber for vaporizing the liquid refrigerant that accumulates there; the heat transfer coil defining a passageway for circulating an externally supplied heat exchange fluid; transferring heat efficiently from the fluid; and freely allowing vaporized refrigerant to escape upwardly from the liquid refrigerant; and a refrigerant discharge conduit penetrating sealingly through the top and traversing substantially the length of the pressurized vessel downwardly and upwardly such that its inlet is near the top of the pressurized vessel so as to provide a means for transporting refrigerant vapor from the vessel. The refrigerant discharge conduit has metering orifices, or passageways, penetrating laterally through its walls near the bottom, communicating respectively interiorly and exteriorly of the overflow chamber for controllably carrying small amounts of liquid refrigerant and oil to the effluent stream of refrigerant gas.

  19. Intergenerational Exchanges in Mexico

    Science.gov (United States)

    Gomes, Cristina

    2017-01-01

    This article analyses exchanges of support between the elderly and adult generations and by gender, based on data from the United Nations household survey in Mexico City (SABE, 2000), and the National Study of Ageing and Health (ENASEM, 2001). Results indicate that in Mexico both generations – elderly parents and adult children – provide support, such as money, services, care or gifts for grandchildren, according to gender roles and the generation’s resources. Men provide monetary support and reproduce their role as family providers, but this role depends on having an income from work and, in later years, a pension, a more common situation among men than among women. Women develop their female domestic role as caregivers. They do not have a formal income, but receive informal economic support and offer services and care to their relatives, reproducing their invisible and unpaid work during their life course. Both types of support are widely exchanged between elderly parents and adult children and children-in-law. PMID:29375143

  20. Structural behavior of Tl-exchanged natrolite at high pressure depending on the composition of pressure-transmitting medium

    Science.gov (United States)

    Seryotkin, Yu. V.; Bakakin, V. V.; Likhacheva, A. Yu.; Dementiev, S. N.; Rashchenko, S. V.

    2017-10-01

    The structural evolution of Tl-exchanged natrolite with idealized formula Tl2[Al2Si3O10]·2H2O, compressed in penetrating (water:ethanol 1:1) and non-penetrating (paraffin) media, was studied up to 4 GPa. The presence of Tl+ with non-bonded electron lone pairs, which can be either stereo-chemically active or passive, determines distinctive features of the high-pressure behavior of the Tl-form. The effective volume of assemblages Tl+(O,H2O) n depends on the E-pairs activity: single-sided coordination correlates with smaller volumes. At ambient conditions, there are two types of Tl positions, only one of them having a nearly single-sided coordination as a characteristic of stereo-activity of the Tl+ E pair. Upon the compression in paraffin, a phase transition occurs: a 5% volume contraction of flexible natrolite framework is accompanied by the conversion of all the Tl+ cations into stereo-chemically active state with a single-sided coordination. This effect requires the reconstruction of all the extra-framework subsystems with the inversion of the cation and H2O positions. The compression in water-containing medium leads to the increase of H2O content up to three molecules pfu through the filling of partly vacant positions. This hinders a single-sided coordination of Tl ions and preserves the configuration of their ion-molecular subsystem. It is likely that the extra-framework subsystem is responsible for the super-structure modulation.

  1. Development, Fabrication, and Testing of a Liquid/Liquid Microchannel Heat Exchanger for Constellation Spacecrafts

    Science.gov (United States)

    Hawkins-Reynolds, Ebony; Le, Hung; Stephan, Ryan

    2010-01-01

    Microchannel technology can be incorporated into heat exchanger designs to decrease the mass and volume of space hardware. The National Aeronautics and Space Administration at the Johnson Space Center (NASA JSC) partnered with Pacific Northwest National Laboratories (PNNL) to develop a liquid/liquid microchannel heat exchanger that has significant mass and volume savings without sacrificing thermal and pressure drop performance. PNNL designed the microchannel heat exchanger to the same performance design requirements of a conventional plate and fin liquid/liquid heat exchanger; 3 kW duty with inlet temperatures of 26 C and 4 C. Both heat exchangers were tested using the same test parameters on a test apparatus and performance data compared.

  2. Conceptualizations for cleaning OTEC heat exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Rice, M.S.; Hagel, D.; Conn, A.F.

    1978-09-01

    A critical operating aspect of Ocean Thermal Energy Conversion (OTEC) plants is the maintenance of clean surfaces on the seawater-side of the heat exchangers. The objective of this program was to assess the state of the art of biofouling control techniques and to evaluate the potential of these existing methods for solving the biofouling problems in the OTEC system. The first task of the program involved an in-depth review and discussion of various fouling control methods including water treatment, surface conditioning, and cleaning techniques. The methods considered applicable to OTEC were identified. This volume summarizes the second task of the program. The compatibility of the various cleaning and fouling control techniques with the different proposed heat exchanger designs and materials are discussed. Also provided are conceptual illustrations for adapting and incorporating the methods into an OTEC power plant. These conceptual designs suggest means for overcoming some of the shortcomings of the techniques which are considered suitable, however, detailed designs of the modified systems are beyond the scope of this report. Chlorination, chemical cleaning, Amertap recirculating sponge rubber balls, and MAN flow-driven brushes are the methods considered applicable for tubular heat exchangers with seawater inside the tubes. Water jets are suggested for the open-cycle and the ''trombone'' (Applied Physics Laboratory) heat exchanger designs. Although none of the methods are immediately applicable to OTEC in their present configuration, in several cases only minor developmental efforts should produce designs which can satisfy the stringent OTEC cleanliness requirements. Further research and development appear warranted for a number of other methods which indicate promise for long-range applicability. Specific recommendations are included.

  3. Image-Guided Radiation Therapy for Muscle-Invasive Carcinoma of the Urinary Bladder with Cone Beam CT Scan: Use of Individualized Internal Target Volumes for a Single Patient

    Directory of Open Access Journals (Sweden)

    Gagan Saini

    2012-09-01

    Full Text Available Introduction: While planning radiation therapy (RT for a carcinoma of the urinary bladder (CaUB, the intra-fractional variation of the urinary bladder (UB volume due to filling-up needs to be accounted for. This internal target volume (ITV is obtained by adding internal margins (IM to the contoured bladder. This study was planned to propose a method of acquiring individualized ITVs for each patient and to verify their reproducibility. Methods: One patient with CaUB underwent simulation with the proposed ‘bladder protocol’. After immobilization, a planning CT scan on empty bladder was done. He was then given 300 ml of water to drink and the time (T was noted. Planning CT scans were performed after 20 min (T+20, 30 min (T+30 and 40 min (T+40. The CT scan at T+20 was co-registered with the T+30 and T+40 scans. The bladder volumes at 20, 30 and 40 min were then contoured as CTV20, CTV30 and CTV40 to obtain an individualized ITV for our patient. For daily treatment, he was instructed to drink water as above, and the time was noted; treatment was started after 20 min. Daily pre- and post-treatment cone beam CT (CBCT scans were done. The bladder visualized on the pre-treatment CBCT scan was compared with CTV20 and on the post-treatment CBCT scan with CTV30. Results: In total, there were 65 CBCT scans (36 pre- and 29 post-treatment. Individualized ITVs were found to be reproducible in 93.85% of all instances and fell outside in 4 instances. Conclusions: The proposed bladder protocol can yield a reproducible estimation of the ITV during treatment; this can obviate the need for taking standard IMs.

  4. Characteristics of floc formation of anion and cation exchange resin in precoat filter using powdered ion exchange resin

    International Nuclear Information System (INIS)

    Adachi, Tetsurou; Sawa, Toshio; Shindoh, Toshikazu.

    1989-01-01

    The filtration performance of mixed filter aid consisting of powdered anion and cation exchange resins used in the precoat filter is closely related to the characteristics of floc formation. The physical, chemical and electrochemical properties of powdered ion exchange resin were measured and the factors related to floc formation of anion and cation exchange resin were investigated by measuring the specific settle volume of resin floc as an evaluating index. It was found that these factors were mixing ratio, nature of resins and particle size of resins. In addition, it was assumed on the bases of these results that the amount of resin floc was related to sum of the surface electric charges of both resins. The filling ratio of resin floc was related to their product by multiplication and an experimental expression was obtained. The specific settle volume of resin floc could then be simulated by particle size, surface area, ion exchange capacity and degree of ionization of the powdered ion exchange resin. (author)

  5. Characteristics of floc formation of anion and cation exchange resin in precoat filter using powdered ion exchange resin

    Energy Technology Data Exchange (ETDEWEB)

    Adachi, Tetsurou (Nitto Denko Corp., Ibaraki, Osaka (Japan)); Sawa, Toshio; Shindoh, Toshikazu

    1989-09-01

    The filtration performance of mixed filter aid consisting of powdered anion and cation exchange resins used in the precoat filter is closely related to the characteristics of floc formation. The physical, chemical and electrochemical properties of powdered ion exchange resin were measured and the factors related to floc formation of anion and cation exchange resin were investigated by measuring the specific settle volume of resin floc as an evaluating index. It was found that these factors were mixing ratio, nature of resins and particle size of resins. In addition, it was assumed on the bases of these results that the amount of resin floc was related to sum of the surface electric charges of both resins. The filling ratio of resin floc was related to their product by multiplication and an experimental expression was obtained. The specific settle volume of resin floc could then be simulated by particle size, surface area, ion exchange capacity and degree of ionization of the powdered ion exchange resin. (author).

  6. Nosehouse: heat-conserving ventilators based on nasal counterflow exchangers.

    Science.gov (United States)

    Vogel, Steven

    2009-12-01

    Small birds and mammals commonly minimize respiratory heat loss with reciprocating counterflow exchangers in their nasal passageways. These animals extract heat from the air in an exhalation to warm those passageways and then use that heat to warm the subsequent inhalation. Although the near-constant volume of buildings precludes direct application of the device, a pair of such exchangers located remotely from each other circumvents that problem. A very simple and crudely constructed small-scale physical model of the device worked well enough as a heat conserver to suggest utility as a ventilator for buildings.

  7. Development of diffusion welded compact heat exchanger technology

    International Nuclear Information System (INIS)

    Mortean, M.V.V.; Cisterna, L.H.R.; Paiva, K.V.; Mantelli, M.B.H.

    2016-01-01

    Highlights: • Four new fabrication technologies for compact heat exchanger cores are presented. • The heat exchangers tested are fabricated by diffusion bonding process. • Results showed that cut-plate heat exchanger is the most promising technology. • Experimental results were compared favorably with numerical and analytical results. - Abstract: Compact heat exchangers are heat transfer equipment employed in applications where weight and volume are significantly relevant constraints, such as vehicles (automotive, maritime, avionics and space). The main characteristic of this equipment is the high heat transfer rate for small volumes. Only recently compact heat exchangers have received greater attention from the researchers, and therefore, manufacturing processes and mathematical modeling still demand development. The main objective of this work is to present and analyze four new fabrication technologies for compact heat exchanger cores, resulting in small cross sectional controlled geometry. Three of them consist of sandwiches of flat plates filled with: parallel circular wires, rectangular wires or rectangular tubes. The fourth consists of stacking flat plates interfiled with water jet machined plates. In all these procedures, stacks of metal layers are formed and diffusion bonding process is proposed for soldering. Copper prototypes were constructed to test the fabrication technologies. Results showed that stacking layers of machined comb-like plates interfiled with flat plates is the most promising fabrication technology, which was used to construct a copper prototype that was tested using water as both hot and cold fluids. The present technology was compared for both the volumetric power and the overall heat transfer coefficients with other heat exchangers, presenting an intermediate performance. Experimental results were compared favorably with numerical and analytical results from the literature.

  8. Developing bulk exchange spring magnets

    Science.gov (United States)

    Mccall, Scott K.; Kuntz, Joshua D.

    2017-06-27

    A method of making a bulk exchange spring magnet by providing a magnetically soft material, providing a hard magnetic material, and producing a composite of said magnetically soft material and said hard magnetic material to make the bulk exchange spring magnet. The step of producing a composite of magnetically soft material and hard magnetic material is accomplished by electrophoretic deposition of the magnetically soft material and the hard magnetic material to make the bulk exchange spring magnet.

  9. Finnish exchange students' culture shock

    OpenAIRE

    Pekkala, Karoliina

    2015-01-01

    This bachelor’s thesis is written about culture shock experienced by the exchange students from Finland. It is commissioned by an international students exchange organisation located in Finland. The aim of the research was to find out how much the host country affects the culture shock and to identify aspects that affect the adaptation of the students. The goal is to provide the future exchange students with advise on coping with culture shock. Theoretical framework consists of defining w...

  10. Deuterium-hydrogen monothermal exchange

    International Nuclear Information System (INIS)

    Rae, H.K.

    1975-01-01

    A monothermal exchange process of extracting deuterium from ammonia synthesis gas is described. This process comprises passing the gas through an exchage liquid stream consisting of a liquid amine having up to five carbon atoms per molecule to cause deuterium to be transferred from the synthesis gas to the exchange liquid, and removing a stream of exchange liquid enriched in deuterium therefrom. (Patent Office Record)

  11. Deuterium exchange in carbonyl compounds

    International Nuclear Information System (INIS)

    Lamaty, G.

    1976-01-01

    After giving a brief outline of the theoretical study of H/D exchange the reaction mechanisms of enolization of ketones and of ketonization of enols are discussed. The orientation of the exchange in aliphatic ketones and the stereochemistry of the exchange in rigid cyclic ketones are dealt with. Some other ketonic systems and carboxylic acids and their derivatives are also considered. (B.R.H.)

  12. Vertical air mass exchange driven by the local circulation on the northern slope of Mount Everest

    Science.gov (United States)

    Zhou, Libo; Zou, Han; Ma, Shupo; Li, Peng; Zhu, Jinhuan; Huo, Cuiping

    2011-01-01

    To better understand vertical air mass exchange driven by local circulation in the Himalayas, the volume flux of air mass is estimated in the Rongbuk Valley on the northern slope of Mount Everest, based on a volume closure method and wind-profiler measurements during the HEST2006 campaign in June 2006. Vertical air mass exchange was found to be dominated by a strong downward mass transfer from the late morning to late night. The average vertical air volume flux was 0.09 m s-1, which could be equivalent to a daily ventilation of 30 times the enclosed valley volume. This vertical air mass exchange process was greatly affected by the evolution of the South Asian summer monsoon (SASM), with a strong downward transfer during the SASM break stage, and a weak transfer during the SASM active stage.

  13. Simulated North Atlantic-Nordic Seas water mass exchanges in an isopycnic coordinate OGCM

    OpenAIRE

    Nilsen, Jan Even Øie; Gao, Yongqi; Drange, Helge; Furevik, Tore; Bentsen, Mats

    2003-01-01

    The variability in the volume exchanges between the North Atlantic and the Nordic Seas during the last 50 years is investigated using a synoptic forced, global version of the Miami Isopycnic Coordinate Ocean Model (MICOM). The simulated volume fluxes agree with the existing observations. The net volume flux across the Faroe-Shetland Channel (FSC) is positively correlated with the net flux through the Denmark Strait (DS; R = 0.74 for 3 years low pass filtering), but negatively correlated with ...

  14. Charge exchange processes involving iron ions

    International Nuclear Information System (INIS)

    Phaneuf, R.A.

    1985-01-01

    A review and evaluation is given of the experimental data which are available for charge exchange processes involving iron ions and neutral H, H 2 and He. Appropriate scaling laws are presented, and their accuracy estimated for these systems. A bibliography is given of available data sources, as well as of useful data compilations and review articles. A procedure is recommended for providing single approximate formulae to the fusion community to describe total cross sections for electron capture by partially-stripped Fe/sup q+/ ions in collisions with H, H 2 and He, based on the scaling relationships suggested by Janev and Hvelplund

  15. Mastering Microsoft Exchange Server 2013

    CERN Document Server

    Elfassy, David

    2013-01-01

    The bestselling guide to Exchange Server, fully updated for the newest version Microsoft Exchange Server 2013 is touted as a solution for lowering the total cost of ownership, whether deployed on-premises or in the cloud. Like the earlier editions, this comprehensive guide covers every aspect of installing, configuring, and managing this multifaceted collaboration system. It offers Windows systems administrators and consultants a complete tutorial and reference, ideal for anyone installing Exchange Server for the first time or those migrating from an earlier Exchange Server version.Microsoft

  16. Hybrid Heat Exchangers

    Science.gov (United States)

    Tu, Jianping Gene; Shih, Wei

    2010-01-01

    A hybrid light-weight heat exchanger concept has been developed that uses high-conductivity carbon-carbon (C-C) composites as the heat-transfer fins and uses conventional high-temperature metals, such as Inconel, nickel, and titanium as the parting sheets to meet leakage and structural requirements. In order to maximize thermal conductivity, the majority of carbon fiber is aligned in the fin direction resulting in 300 W/m.K or higher conductivity in the fin directions. As a result of this fiber orientation, the coefficient of thermal expansion (CTE) of the C-C composite in both non-fiber directions matches well with the CTE of various high-temperature metal alloys. This allows the joining of fins and parting sheets by using high-temperature braze alloys.

  17. Catalysed hydrogen isotope exchange

    International Nuclear Information System (INIS)

    1973-01-01

    A method is described for enhancing the rate of exchange of hydrogen atoms in organic compounds or moieties with deuterium or tritium atoms. It comprises reacting the organic compound or moiety and a compound which is the source of deuterium or tritium in the presence of a catalyst consisting of a non-metallic, metallic or organometallic halide of Lewis acid character and which is reactive towards water, hydrogen halides or similar protonic acids. The catalyst is a halide or organometallic halide of: (i) zinc or another element of Group IIb; (ii) boron, aluminium or another element of Group III; (iii) tin, lead, antimony or another element of Groups IV to VI; or (iv) a transition metal, lanthanide or stable actinide; or a halohalide. (author)

  18. The Radioecology Exchange

    Energy Technology Data Exchange (ETDEWEB)

    Barnett, Catherine L.; Beresford, Nicholas A.; Patel, Sabera; Wells, Claire; Howard, Brenda J. [NERC Centre for Ecology and Hydrology, CEH Lancaster, Lancaster Environment Centre, Library Av., Bailrigg, Lancaster, LA1 4AP (United Kingdom); Mora, Juan Carlos; Real, Almudena [Centro de Investigaciones Energeticas, Medioambientales y Tecnologicas (CIEMAT), Avenida complutense 22, Madrid, 28040 (Spain); Beaugelin-Seiller, Karine; Gilbin, Rodolphe; Hinton, Thomas [IRSN-Institut de Radioprotection et de Surete Nucleaire, 31, Avenue de la Division Leclerc, 92260 Fontenay-Aux-Roses (France); Vesterbacka, Pia; Muikku, Maarit; Outola, Iisa [Radiation and Nuclear Safety Authority, P.O. Box 14, FI-00881 Helsinki (Finland); Skuterud, Lavrans; AlbumYtre-Eide, Martin [Norwegian Radiation Protection Authority, Grini Naeringspark 13, Oesteraas, 1332 (Norway); Bradshaw, Clare; Stark, Karolina; Jaeschke, Ben [Stockholms Universitet, Universitetsvaegen 10, Stockholm, 10691 (Sweden); Oughton, Deborah; Skipperud, Lindis [NMBU Norwegian University of Life Science P.O. Box 5003N-1432 Aas, Oslo (Norway); Vandenhove, Hildegarde; Vanhoudt, Nathalie [SCK.CEN, Studiecentrum voor Kernenergie/Centre d' Etude de l' Energie Nucleaire, Avenue Herrmann-Debroux 40, BE-1160 Brussels (Belgium); Willrodt, Christine; Steiner, Martin [Bundesamt fuer Strahlenschutz, Willy-Brandt-Strasse 5, 38226 Salzgitter (Germany)

    2014-07-01

    The Radioecology Exchange (www.radioecology-exchange.org) was created in 2011 under the EU FP7 STAR (Strategy for Allied Radioecology) network of excellence. The project aims to integrate the research efforts on radioecology of nine European organisations into a sustainable network. The web site (together with associated Twitter feeds and Facebook page) currently provides the gateway to project outputs and other on-line radiation protection and radioecological resources. In 2013, the EU FP7 COMET (Coordination and implementation of a pan-European instrument for radioecology) project commenced; it aims to strengthen research on the impact of radiation on man and the environment. COMET includes the STAR partners with the addition of one Japanese and two Ukrainian research institutes. As STAR and COMET interact closely together and with the European Radioecology Alliance (www.er-alliance.org/), the Radioecology Exchange will be modified to become an international 'hub' for information related to radioecology. Project specific information will be hosted on separate web sites www.star-radioecology.org and www.comet-radioecology.org. This paper will present an overview of the resources hosted on the Radioecology Exchange inviting other scientists to contribute. Highlighted aspects of the site include: Social media (News blog, Twitter, Facebook) - Items announcing project outputs, training courses, jobs, studentships etc. Virtual laboratory - Information which encourages integration through joint research and integrated use of data and sample materials. These pages will focus on three categories: (1) Methodological: descriptions and video clips of commonly used analytical methods and protocols and the procedures used in STAR and COMET; (2) Informative: databases made available by STAR/COMET partners together with details of sample archives held. Fact-sheets on radio-ecologically important radionuclides and 'topical descriptions' which show absorbed

  19. Lipid exchange by ultracentrifugation

    DEFF Research Database (Denmark)

    Drachmann, Nikolaj Düring; Olesen, Claus

    2014-01-01

    Lipids play an important role in maintaining P-type ATPase structure and function, and often they are crucial for ATPase activity. When the P-type ATPases are in the membrane, they are surrounded by a mix of different lipids species with varying aliphatic chain lengths and saturation, and the com......Lipids play an important role in maintaining P-type ATPase structure and function, and often they are crucial for ATPase activity. When the P-type ATPases are in the membrane, they are surrounded by a mix of different lipids species with varying aliphatic chain lengths and saturation...... step, where the protein sample is spun through a dense buffer containing large excess of the target lipid, which results in an approximately 80-85 % lipid exchange. The method is a very gently technique that maintains protein folding during the process, hence allowing further characterization...

  20. Accuracy of local exchange in the calculation of continuum wavefunctions

    International Nuclear Information System (INIS)

    Biava, D A; Bartschat, K; Saha, H P; Madison, D H

    2002-01-01

    It is well known that electron exchange can play an important role in electron-impact elastic, inelastic and ionization scattering from atoms and molecules. The proper theoretical treatment of exchange yields an inhomogeneous differential equation with a non-local exchange operator. To simplify the calculation, a local approximation is often made for this non-local operator. In this paper, we examine the accuracy of this approximation for the calculation of elastic scattering continuum waves in the presence of an argon ion with a single vacancy in the p-shell. It is found that one can reliably use the local exchange approximation for ionization leading to s-state vacancies but not p-state vacancies

  1. Anomalous atomic volume of alpha-Pu

    DEFF Research Database (Denmark)

    Kollar, J.; Vitos, Levente; Skriver, Hans Lomholt

    1997-01-01

    We have performed full charge-density calculations for the equilibrium atomic volumes of the alpha-phase light actinide metals using the local density approximation (LDA) and the generalized gradient approximation (GGA). The average deviation between the experimental and the GGA atomic radii is 1.......3%. The comparison between the LDA and GGA results show that the anomalously large atomic volume of alpha-Pu relative to alpha-Np can be ascribed to exchange-correlation effects connected with the presence of low coordinated sites in the structure where the f electrons are close to the onset of localization...

  2. Transition density of charge-exchange processes

    International Nuclear Information System (INIS)

    Lovas, R.G.

    1983-01-01

    The transition density between parent and analogue states is studied with special reference to its role in charge-exchange nuclear reactions. The structure of the target nucleus is described in a perturbative approach, in which the Coulomb and asymmetry potentials mix the eigenstates of a charge-independent single-particle Hamiltonian. In this model formulae are derived for the transition density, the Coulomb displacement energy and the neutron-proton density difference, and their relationship is used to estimate the transition density. This estimate shows that: the largest contribution comes from the density of the excess neutrons; the weight of the Coulomb-mixing effect is small up to excess neutron number 10, and grows rapidly beyond; the weight of the core polarization term induced by the excess neutrons is modest and is the same for all nuclei. It is indicated that the Coulomb effect may explain the departure from the Lane model of nucleon charge-exchange scattering found for heavy nuclei, whereas the core polarization may account for the observed anomalous dependence of the deg 0 pion charge-exchange cross section on the number of excess neutrons. (author)

  3. Fluid mechanics experiments in oscillatory flow. Volume 1

    International Nuclear Information System (INIS)

    Seume, J.; Friedman, G.; Simon, T.W.

    1992-03-01

    Results of a fluid mechanics measurement program is oscillating flow within a circular duct are present. The program began with a survey of transition behavior over a range of oscillation frequency and magnitude and continued with a detailed study at a single operating point. Such measurements were made in support of Stirling engine development. Values of three dimensionless parameters, Re max , Re W , and A R , embody the velocity amplitude, frequency of oscillation and mean fluid displacement of the cycle, respectively. Measurements were first made over a range of these parameters which included operating points of all Stirling engines. Next, a case was studied with values of these parameters that are representative of the heat exchanger tubes in the heater section of NASA's Stirling cycle Space Power Research Engine (SPRE). Measurements were taken of the axial and radical components of ensemble-averaged velocity and rms-velocity fluctuation and the dominant Reynolds shear stress, at various radial positions for each of four axial stations. In each run, transition from laminar to turbulent flow, and in reverse, were identified and sufficient data was gathered to propose the transition mechanism. Models of laminar and turbulent boundary layers were used to process the data into wall coordinates and to evaluate skin friction coefficients. Such data aids in validating computational models and is useful in comparing oscillatory flow characteristics to those of fully-developed steady flow. Data were taken with a contoured entry to each end of the test section and with flush square inlets so that the effects of test section inlet geometry on transition and turbulence are documented. The following is presented in two-volumes. Volume I contains the text of the report including figures and supporting appendices. Volume II contains data reduction program listings and tabulated data (including its graphical presentation)

  4. Copper metal foam as an essential construction element of innovative heat exchanger

    Directory of Open Access Journals (Sweden)

    R. Rybár

    2016-07-01

    Full Text Available Paper deals with creation of the innovative heat exchanger - manifold header for the heat pipe evacuated tube solar collector, which essential functional element is heat exchange chamber made of the copper metal foam. Design of the heat exchanger is based on effective utilization of the unique properties of the metal foam which makes it possible to design highly effective and space saving devices. Inner volume of heat exchanger was reducing from 0,00045 m3 to 0,000135 m3 and heat exchange surface was increase from 0,0104 m2 to 0,1403 m2 at proposed prototype, what drastically increase heat exchange efficiency. The proposal itself is based on the unique physical properties of the metal foam, which was described by computational analysis.

  5. Modeling ion exchange in clinoptilolite using the EQ3/6 geochemical modeling code

    International Nuclear Information System (INIS)

    Viani, B.E.; Bruton, C.J.

    1992-06-01

    Assessing the suitability of Yucca Mtn., NV as a potential repository for high-level nuclear waste requires the means to simulate ion-exchange behavior of zeolites. Vanselow and Gapon convention cation-exchange models have been added to geochemical modeling codes EQ3NR/EQ6, allowing exchange to be modeled for up to three exchangers or a single exchanger with three independent sites. Solid-solution models that are numerically equivalent to the ion-exchange models were derived and also implemented in the code. The Gapon model is inconsistent with experimental adsorption isotherms of trace components in clinoptilolite. A one-site Vanselow model can describe adsorption of Cs or Sr on clinoptilolite, but a two-site Vanselow exchange model is necessary to describe K contents of natural clinoptilolites

  6. Vapor Compression and Thermoelectric Heat Pump Heat Exchangers for a Condensate Distillation System: Design and Experiment

    Science.gov (United States)

    Erickson, Lisa R.; Ungar, Eugene K.

    2013-01-01

    Maximizing the reuse of wastewater while minimizing the use of consumables is critical in long duration space exploration. One of the more promising methods of reclaiming urine is the distillation/condensation process used in the cascade distillation system (CDS). This system accepts a mixture of urine and toxic stabilizing agents, heats it to vaporize the water and condenses and cools the resulting water vapor. The CDS wastewater flow requires heating and its condensate flow requires cooling. Performing the heating and cooling processes separately requires two separate units, each of which would require large amounts of electrical power. By heating the wastewater and cooling the condensate in a single heat pump unit, mass, volume, and power efficiencies can be obtained. The present work describes and compares two competing heat pump methodologies that meet the needs of the CDS: 1) a series of mini compressor vapor compression cycles and 2) a thermoelectric heat exchanger. In the paper, the system level requirements are outlined, the designs of the two heat pumps are described in detail, and the results of heat pump performance tests are provided. A summary is provided of the heat pump mass, volume and power trades and a selection recommendation is made.

  7. Estimation of Bid Curves in Power Exchanges using Time-varying Simultaneous-Equations Models

    Science.gov (United States)

    Ofuji, Kenta; Yamaguchi, Nobuyuki

    Simultaneous-equations model (SEM) is generally used in economics to estimate interdependent endogenous variables such as price and quantity in a competitive, equilibrium market. In this paper, we have attempted to apply SEM to JEPX (Japan Electric Power eXchange) spot market, a single-price auction market, using the publicly available data of selling and buying bid volumes, system price and traded quantity. The aim of this analysis is to understand the magnitude of influences to the auctioned prices and quantity from the selling and buying bids, than to forecast prices and quantity for risk management purposes. In comparison with the Ordinary Least Squares (OLS) estimation where the estimation results represent average values that are independent of time, we employ a time-varying simultaneous-equations model (TV-SEM) to capture structural changes inherent in those influences, using State Space models with Kalman filter stepwise estimation. The results showed that the buying bid volumes has that highest magnitude of influences among the factors considered, exhibiting time-dependent changes, ranging as broad as about 240% of its average. The slope of the supply curve also varies across time, implying the elastic property of the supply commodity, while the demand curve remains comparatively inelastic and stable over time.

  8. Cation-Exchanged Zeolitic Chalcogenides for CO2 Adsorption.

    Science.gov (United States)

    Yang, Huajun; Luo, Min; Chen, Xitong; Zhao, Xiang; Lin, Jian; Hu, Dandan; Li, Dongsheng; Bu, Xianhui; Feng, Pingyun; Wu, Tao

    2017-12-18

    We report here the intrinsic advantages of a special family of porous chalcogenides for CO 2 adsorption in terms of high selectivity of CO 2 /N 2 , large uptake capacity, and robust structure due to their first-ever unique integration of the chalcogen-soft surface, high porosity, all-inorganic crystalline framework, and the tunable charge-to-volume ratio of exchangeable cations. Although tuning the CO 2 adsorption properties via the type of exchangeable cations has been well-studied in oxides and MOFs, little is known about the effects of inorganic exchangeable cations in porous chalcogenides, in part because ion exchange in chalcogenides can be very sluggish and incomplete due to their soft character. We have demonstrated that, through a methodological change to progressively tune the host-guest interactions, both facile and nearly complete ion exchange can be accomplished. Herein, a series of cation-exchanged zeolitic chalcogenides (denoted as M@RWY) were studied for the first time for CO 2 adsorption. Samples were prepared through a sequential ion-exchange strategy, and Cs + -, Rb + -, and K + -exchanged samples demonstrated excellent CO 2 adsorption performance. Particularly, K@RWY has the superior CO 2 /N 2 selectivity with the N 2 adsorption even undetected at either 298 or 273 K. It also has the large uptake of 6.3 mmol/g (141 cm 3 /g) at 273 K and 1 atm with an isosteric heat of 35-41 kJ mol -1 , the best among known porous chalcogenides. Moreover, it permits a facile regeneration and exhibits an excellent recyclability, as shown by the multicycling adsorption experiments. Notably, K@RWY also demonstrates a strong tolerance toward water.

  9. The market microstructure of the European Climate Exchange

    OpenAIRE

    Mizrach, Bruce; Otsubo, Yoichi

    2011-01-01

    This paper analyzes the market microstructure of the European Climate Exchange, the largest EU ETS trading venue. The ECX captures 2/3 of the screen traded market in EUA and more than 90% in CER. 2009 Trading volumes total ?22 billion and are growing, with EUA transactions doubling, and CER volume up 61%. Spreads range from ?0:02 to ?0:06 for EUA and from ?0:07 to ?0:18 for CER. Market impact estimates imply that an average trade will move the EUA market by 1.08 euro centimes and the CER mark...

  10. Equal exchange: Determining a fair price for carbon

    Energy Technology Data Exchange (ETDEWEB)

    Hodes, G.; Kamel, S.

    2007-12-14

    This first volume in the new series CD4CDM Perspective Series focuses on determining an equal exchange between carbon buyers and sellers in CDM transactions. Contributors to this volume represent a wide spectrum of the various market actors that are interacting in order to realize both successful and equitable carbon transactions. The following issues are discussed: Global carbon price dynamics; CDM project risk profiles and/or premiums; Importance of time factors and delivery guarantees; Impact of regulatory drivers and post-Kyoto outlook; Region-specific outlooks; Strategies, contracting models and approaches. (BA)

  11. New type fuel exchange system

    International Nuclear Information System (INIS)

    Meshii, Toshio; Maita, Yasushi; Hirota, Koichi; Kamishima, Yoshio.

    1988-01-01

    When the reduction of the construction cost of FBRs is considered from the standpoint of the machinery and equipment, to make the size small and to heighten the efficiency are the assigned mission. In order to make a reactor vessel small, it is indispensable to decrease the size of the equipment for fuel exchange installed on the upper part of a core. Mitsubishi Heavy Industries Ltd. carried out the research on the development of a new type fuel exchange system. As for the fuel exchange system for FBRs, it is necessary to change the mode of fuel exchange from that of LWRs, such as handling in the presence of chemically active sodium and inert argon atmosphere covering it and handling under heavy shielding against high radiation. The fuel exchange system for FBRs is composed of a fuel exchanger which inserts, pulls out and transfers fuel and rotary plugs. The mechanism adopted for the new type fuel exchange system that Mitsubishi is developing is explained. The feasibility of the mechanism on the upper part of a core was investigated by water flow test, vibration test and buckling test. The design of the mechanism on the upper part of the core of a demonstration FBR was examined, and the new type fuel exchange system was sufficiently applicable. (Kako, I.)

  12. Tube in shell heat exchangers

    International Nuclear Information System (INIS)

    Hayden, O.; Willby, C.R.; Sheward, G.E.; Ormrod, D.T.; Firth, G.F.

    1980-01-01

    An improved tube-in-shell heat exchanger to be used between liquid metal and water is described for use in the liquid metal coolant system of fast breeder reactors. It is stated that this design is less prone to failures which could result in sodium water reactions than previous exchangers. (UK)

  13. Lung volume reduction for emphysema.

    Science.gov (United States)

    Shah, Pallav L; Herth, Felix J; van Geffen, Wouter H; Deslee, Gaetan; Slebos, Dirk-Jan

    2017-02-01

    Advanced emphysema is a lung disease in which alveolar capillary units are destroyed and supporting tissue is lost. The combined effect of reduced gas exchange and changes in airway dynamics impairs expiratory airflow and leads to progressive air trapping. Pharmacological therapies have limited effects. Surgical resection of the most destroyed sections of the lung can improve pulmonary function and exercise capacity but its benefit is tempered by significant morbidity. This issue stimulated a search for novel approaches to lung volume reduction. Alternative minimally invasive approaches using bronchoscopic techniques including valves, coils, vapour thermal ablation, and sclerosant agents have been at the forefront of these developments. Insertion of endobronchial valves in selected patients could have benefits that are comparable with lung volume reduction surgery. Endobronchial coils might have a role in the treatment of patients with emphysema with severe hyperinflation and less parenchymal destruction. Use of vapour thermal energy or a sclerosant might allow focal treatment but the unpredictability of the inflammatory response limits their current use. In this Review, we aim to summarise clinical trial evidence on lung volume reduction and provide guidance on patient selection for available therapies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. A CFD Analysis of The Performance of Pin-Fin Laminar Flow Micro/Meso Scale Heat Exchangers

    National Research Council Canada - National Science Library

    Dimas, Sotirios

    2005-01-01

    A full three dimensional computational study was carried out using a finite-volume based solver for analyzing the performance of pin-fin based micro/meso scale heat exchangers with air as the working fluid...

  15. Next Generation Microchannel Heat Exchangers

    CERN Document Server

    Ohadi, Michael; Dessiatoun, Serguei; Cetegen, Edvin

    2013-01-01

    In Next Generation Microchannel Heat Exchangers, the authors’ focus on the new generation highly efficient heat exchangers and presentation of novel data and technical expertise not available in the open literature.  Next generation micro channels offer record high heat transfer coefficients with pressure drops much less than conventional micro channel heat exchangers. These inherent features promise fast penetration into many mew markets, including high heat flux cooling of electronics, waste heat recovery and energy efficiency enhancement applications, alternative energy systems, as well as applications in mass exchangers and chemical reactor systems. The combination of up to the minute research findings and technical know-how make this book very timely as the search for high performance heat and mass exchangers that can cut costs in materials consumption intensifies.

  16. Heat exchanger leakage problem location

    Directory of Open Access Journals (Sweden)

    Jícha Miroslav

    2012-04-01

    Full Text Available Recent compact heat exchangers are very often assembled from numerous parts joined together to separate heat transfer fluids and to form the required heat exchanger arrangement. Therefore, the leak tightness is very important property of the compact heat exchangers. Although, the compact heat exchangers have been produced for many years, there are still technological problems associated with manufacturing of the ideal connection between the individual parts, mainly encountered with special purpose heat exchangers, e.g. gas turbine recuperators. This paper describes a procedure used to identify the leakage location inside the prime surface gas turbine recuperator. For this purpose, an analytical model of the leaky gas turbine recuperator was created to assess its performance. The results obtained are compared with the experimental data which were acquired during the recuperator thermal performance analysis. The differences between these two data sets are used to indicate possible leakage areas.

  17. Transendothelial lipoprotein exchange and microalbuminuria

    DEFF Research Database (Denmark)

    Jensen, Jan Skov; Feldt-Rasmussen, Bo; Jensen, Kurt Svarre

    2004-01-01

    . METHODS: Using an in vivo isotope technique, transendothelial exchange of low density lipoprotein (LDL) was measured in 77 non-diabetic individuals. Autologous 131-iodinated LDL was reinjected intravenously, and the 1-h fractional escape rate was calculated as index of transendothelial exchange. RESULTS......OBJECTIVE: Microalbuminuria associates with increased risk of atherosclerosis in individuals without diabetes. We hypothesized that transendothelial lipoprotein exchange is elevated among such individuals, possibly explaining increased intimal lipoprotein accumulation and thus atherosclerosis......: There was no difference in transendothelial LDL exchange between subjects with microalbuminuria versus normoalbuminuria (mean (95% confidence interval) 3.8%/h (3.3-4.3%/h) versus 4.2%/h (3.7-4.7%/h); P=0.33). In contrast, there was a positive correlation between transendothelial LDL exchange and (logarithmically...

  18. A Mass Computation Model for Lightweight Brayton Cycle Regenerator Heat Exchangers

    Science.gov (United States)

    Juhasz, Albert J.

    2010-01-01

    Based on a theoretical analysis of convective heat transfer across large internal surface areas, this paper discusses the design implications for generating lightweight gas-gas heat exchanger designs by packaging such areas into compact three-dimensional shapes. Allowances are made for hot and cold inlet and outlet headers for assembly of completed regenerator (or recuperator) heat exchanger units into closed cycle gas turbine flow ducting. Surface area and resulting volume and mass requirements are computed for a range of heat exchanger effectiveness values and internal heat transfer coefficients. Benefit cost curves show the effect of increasing heat exchanger effectiveness on Brayton cycle thermodynamic efficiency on the plus side, while also illustrating the cost in heat exchanger required surface area, volume, and mass requirements as effectiveness is increased. The equations derived for counterflow and crossflow configurations show that as effectiveness values approach unity, or 100 percent, the required surface area, and hence heat exchanger volume and mass tend toward infinity, since the implication is that heat is transferred at a zero temperature difference. To verify the dimensional accuracy of the regenerator mass computational procedure, calculation of a regenerator specific mass, that is, heat exchanger weight per unit working fluid mass flow, is performed in both English and SI units. Identical numerical values for the specific mass parameter, whether expressed in lb/(lb/sec) or kg/ (kg/sec), show the dimensional consistency of overall results.

  19. 78 FR 19350 - Self-Regulatory Organizations; BATS Exchange, Inc.; Notice of Filing and Immediate Effectiveness...

    Science.gov (United States)

    2013-03-29

    ... physical ports free of charge at the primary data center and charges $2,500 per month for each additional single physical port at such data center. Separately, the Exchange charges $1,000 for each 1G physical port at the secondary data center. The Exchange proposes to normalize its 1G physical port fee at $1...

  20. 75 FR 3950 - Self-Regulatory Organizations; International Securities Exchange, LLC; Order Approving Proposed...

    Science.gov (United States)

    2010-01-25

    ... currency pair has been approved for listing and trading, the Exchange may open for trading series of FX... Rule Change Relating to Foreign Currency Options January 15, 2010. I. Introduction On October 27, 2009... Currency Options (``FX Options'') to permit the Exchange to list a single strike price of one cent ($0.01...

  1. Inclusion of radioactive ion-exchange resins into inorganic binders

    International Nuclear Information System (INIS)

    Epimakhov, V.N.; Olejnik, M.S.

    2005-01-01

    The paper is devoted to inclusion of the radioactive ion-exchange resins into the portland, slag-portland and alumina cements. The degree of filling the solidified products achieves 7-10, 12 and 18.9-19.7% correspondingly under conservation of sufficient strength (not less 5 MPa). The coefficient of waste volume increasing during solidification does not exceed 1.5 under consideration of addition of 10 mass % of clay into aluminia cement [ru

  2. Energy-Exchange Project

    Energy Technology Data Exchange (ETDEWEB)

    1982-04-01

    The purpose of the study was to determine what energy savings can be achieved by coordinating the resources and requirements of two facilities, the 26th Ward Water Pollution Control Plant (WPCP) and a housing development named Starrett City with its own total energy system. It was determined that three energy exchange options were economically and technically feasible. These include: the transfer of digester gas produced at the 26th Ward to the boilers at the Starrett City's total energy plant (TEP); the transfer of hot water heated at the TEP to the 26th Ward for space and process heating; and the transfer of coal effluent waste water from the 26th Ward to the condenser cooling systems at the TEP. Technical information is presented to support the findings. The report addresses those tasks of the statement of work dedicated to data acquisition, analysis, and energy conservation strategies internal to the Starrett City TEP and the community it supplies as well as to the 26th Ward WPCP. (MCW)

  3. Heat exchanger design

    OpenAIRE

    Vítek, Tomáš

    2017-01-01

    Tato bakalářská práce řeší návrh výměníku tepla pro teplovodní kotel se zplyňovací komorou pro předehřev spalovacího vzduchu odpadním teplem spalin. Hodnoty pro výpočet byly experimentálně naměřeny. Práce obsahuje stručný popis trubkového výměníku tepla, stechiometrický vypočet spalování, návrh geometrických rozměrů výměníku, výpočet tlakových ztrát a výpočet výkonu. Její součástí je také výkresová dokumentace navrženého výměníku. This bachelor thesis solves design of a heat exchanger for ...

  4. Multicomponent liquid ion exchange with chabazite zeolites

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, S.M.; Arnold, W.D. Jr.; Byers, C.W.

    1993-10-01

    In spite of the increasing commercial use of zeolites for binary and multicomponent sorption, the understanding of the basic mass-transfer processes associated with multicomponent zeolite ion-exchange systems is quite limited. This study was undertaken to evaluate Na-Ca-Mg-Cs-Sr ion exchange from an aqueous solution using a chabazite zeolite. Mass-transfer coefficients and equilibrium equations were determined from experimental batch-reactor data for single and multicomponent systems. The Langmuir isotherm was used to represent the equilibrium relationship for binary systems, and a modified Dubinin-Polyani model was used for the multicomponent systems. The experimental data indicate that diffusion through the microporous zeolite crystals is the primary diffusional resistance. Macropore diffusion also significantly contributes to the mass-transfer resistance. Various mass-transfer models were compared to the experimental data to determine mass-transfer coefficients. Effective diffusivities were obtained which accurately predicted experimental data using a variety of models. Only the model which accounts for micropore and macropore diffusion occurring in series accurately predicted multicomponent data using single-component diffusivities. Liquid and surface diffusion both contribute to macropore diffusion. Surface and micropore diffusivities were determined to be concentration dependent.

  5. Quantifying Uncertainty in Soil Volume Estimates

    International Nuclear Information System (INIS)

    Roos, A.D.; Hays, D.C.; Johnson, R.L.; Durham, L.A.; Winters, M.

    2009-01-01

    Proper planning and design for remediating contaminated environmental media require an adequate understanding of the types of contaminants and the lateral and vertical extent of contamination. In the case of contaminated soils, this generally takes the form of volume estimates that are prepared as part of a Feasibility Study for Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) sites and/or as part of the remedial design. These estimates are typically single values representing what is believed to be the most likely volume of contaminated soil present at the site. These single-value estimates, however, do not convey the level of confidence associated with the estimates. Unfortunately, the experience has been that pre-remediation soil volume estimates often significantly underestimate the actual volume of contaminated soils that are encountered during the course of remediation. This underestimation has significant implications, both technically (e.g., inappropriate remedial designs) and programmatically (e.g., establishing technically defensible budget and schedule baselines). Argonne National Laboratory (Argonne) has developed a joint Bayesian/geostatistical methodology for estimating contaminated soil volumes based on sampling results, that also provides upper and lower probabilistic bounds on those volumes. This paper evaluates the performance of this method in a retrospective study that compares volume estimates derived using this technique with actual excavated soil volumes for select Formerly Utilized Sites Remedial Action Program (FUSRAP) Maywood properties that have completed remedial action by the U.S. Army Corps of Engineers (USACE) New York District. (authors)

  6. Multifrequency Oscillatory Ventilation in the Premature Lung: Effects on Gas Exchange, Mechanics, and Ventilation Distribution.

    Science.gov (United States)

    Kaczka, David W; Herrmann, Jacob; Zonneveld, C Elroy; Tingay, David G; Lavizzari, Anna; Noble, Peter B; Pillow, J Jane

    2015-12-01

    Despite the theoretical benefits of high-frequency oscillatory ventilation (HFOV) in preterm infants, systematic reviews of randomized clinical trials do not confirm improved outcomes. The authors hypothesized that oscillating a premature lung with multiple frequencies simultaneously would improve gas exchange compared with traditional single-frequency oscillatory ventilation (SFOV). The goal of this study was to develop a novel method for HFOV, termed "multifrequency oscillatory ventilation" (MFOV), which relies on a broadband flow waveform more suitable for the heterogeneous mechanics of the immature lung. Thirteen intubated preterm lambs were randomly assigned to either SFOV or MFOV for 1 h, followed by crossover to the alternative regimen for 1 h. The SFOV waveform consisted of a pure sinusoidal flow at 5 Hz, whereas the customized MFOV waveform consisted of a 5-Hz fundamental with additional energy at 10 and 15 Hz. Per standardized protocol, mean pressure at airway opening ((Equation is included in full-text article.)) and inspired oxygen fraction were adjusted as needed, and root mean square of the delivered oscillatory volume waveform (Vrms) was adjusted at 15-min intervals. A ventilatory cost function for SFOV and MFOV was defined as (Equation is included in full-text article.), where Wt denotes body weight. Averaged over all time points, MFOV resulted in significantly lower VC (246.9 ± 6.0 vs. 363.5 ± 15.9 ml mmHg kg) and (Equation is included in full-text article.)(12.8 ± 0.3 vs. 14.1 ± 0.5 cm H2O) compared with SFOV, suggesting more efficient gas exchange and enhanced lung recruitment at lower mean airway pressures. Oscillation with simultaneous multiple frequencies may be a more efficient ventilator modality in premature lungs compared with traditional single-frequency HFOV.

  7. 75 FR 54411 - Self-Regulatory Organizations; New York Stock Exchange LLC; Notice of Filing and Immediate...

    Science.gov (United States)

    2010-09-07

    ... with the new quoting and volume requirements. The Exchange also proposes to clarify which mnemonics... the same mnemonic for non-SLP trading activity. Background: Rule 107B, which was adopted as a pilot... things, the Exchange requires pursuant to Rule 107B(c)(1) that an SLP use a unique mnemonic for its SLP...

  8. Application of ion exchange to uranium recovery

    International Nuclear Information System (INIS)

    Himsley, A.

    1986-01-01

    The application of ion exchange to uranium recovery involves the study of sorption and elution processes and the effect of competing ions upon the loading of uranium on the resin. The equilibrium loading depends solely upon the concentrations of the various ions in the solution to be treated. The rate at which the resin reaches the equilibrium loading depends upon the competition from other unwanted ions, the concentration of ions and the ratio of volumetric flow rate to resin volume as well as the resin structure, particle size and the temperature of operation. Efficiency of elution depends upon the type and amount of eluant used and the contact time or rate at which the eluant is passed through the bed of resin. It is also dependent upon the resin structure, particle size and the temperature of the eluant. The water retention of the resin beads, which is a measure of crosslinking and porosity also has a marked effect upon the rate of exchange both on sorption and elution. (author)

  9. Ontological modeling of electronic health information exchange.

    Science.gov (United States)

    McMurray, J; Zhu, L; McKillop, I; Chen, H

    2015-08-01

    Investments of resources to purposively improve the movement of information between health system providers are currently made with imperfect information. No inventories of system-level electronic health information flows currently exist, nor do measures of inter-organizational electronic information exchange. Using Protégé 4, an open-source OWL Web ontology language editor and knowledge-based framework, we formalized a model that decomposes inter-organizational electronic health information flow into derivative concepts such as diversity, breadth, volume, structure, standardization and connectivity. The ontology was populated with data from a regional health system and the flows were measured. Individual instance's properties were inferred from their class associations as determined by their data and object property rules. It was also possible to visualize interoperability activity for regional analysis and planning purposes. A property called Impact was created from the total number of patients or clients that a health entity in the region served in a year, and the total number of health service providers or organizations with whom it exchanged information in support of clinical decision-making, diagnosis or treatment. Identifying providers with a high Impact but low Interoperability score could assist planners and policy-makers to optimize technology investments intended to electronically share patient information across the continuum of care. Finally, we demonstrated how linked ontologies were used to identify logical inconsistencies in self-reported data for the study. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Single-centre comparison of a novel single-step balloon inflation ...

    African Journals Online (AJOL)

    Subject. Single-centre comparison of a novel single-step balloon inflation device and Amplatz sheath dilatation during percutaneous nephrolithotomy – a pilot study. Outcome measures. Single procedure success rates, retreatment rates, hospital stay, haemoglobin concentration, calculi volume, calculi configuration, patient ...

  11. Custom, contract, and kidney exchange.

    Science.gov (United States)

    Healy, Kieran; Krawiec, Kimberly D

    2012-01-01

    In this Essay, we examine a case in which the organizational and logistical demands of a novel form of organ exchange (the nonsimultaneous, extended, altruistic donor (NEAD) chain) do not map cleanly onto standard cultural schemas for either market or gift exchange, resulting in sociological ambiguity and legal uncertainty. In some ways, a NEAD chain resembles a form of generalized exchange, an ancient and widespread instance of the norm of reciprocity that can be thought of simply as the obligation to “pay it forward” rather than the obligation to reciprocate directly with the original giver. At the same time, a NEAD chain resembles a string of promises and commitments to deliver something in exchange for some valuable consideration--that is, a series of contracts. Neither of these salient "social imaginaries" of exchange--gift giving or formal contract--perfectly meets the practical demands of the NEAD system. As a result, neither contract nor generalized exchange drives the practice of NEAD chains. Rather, the majority of actual exchanges still resemble a simpler form of exchange: direct, simultaneous exchange between parties with no time delay or opportunity to back out. If NEAD chains are to reach their full promise for large-scale, nonsimultaneous organ transfer, legal uncertainties and sociological ambiguities must be finessed, both in the practices of the coordinating agencies and in the minds of NEAD-chain participants. This might happen either through the further elaboration of gift-like language and practices, or through a creative use of the cultural form and motivational vocabulary, but not necessarily the legal and institutional machinery, of contract.

  12. New perspectives on exchange currents

    International Nuclear Information System (INIS)

    Riska, D.O.

    1991-01-01

    The recently developed method of constructing the nuclear exchange current operators within the framework of the topological soliton (Skyrme) model is described. This approach is theoretically compact, allows treating nucleon and nuclear structure on the same footing and finally can be viewed as an effective low-energy representation of QCD. The approach also leads to some very natural connections between pionic and nuclear transition rates because the effective pion-nucleon interaction involves the isovector (exchange) current operator. Finally, a discussion of the relation between exchange currents and relativistic corrections is given. (author). 76 refs, 6 figs

  13. Heat exchanger with ceramic elements

    Science.gov (United States)

    Corey, John A.

    1986-01-01

    An annular heat exchanger assembly includes a plurality of low thermal growth ceramic heat exchange members with inlet and exit flow ports on distinct faces. A mounting member locates each ceramic member in a near-annular array and seals the flow ports on the distinct faces into the separate flow paths of the heat exchanger. The mounting member adjusts for the temperature gradient in the assembly and the different coefficients of thermal expansion of the members of the assembly during all operating temperatures.

  14. Heat exchanger using graphite foam

    Science.gov (United States)

    Campagna, Michael Joseph; Callas, James John

    2012-09-25

    A heat exchanger is disclosed. The heat exchanger may have an inlet configured to receive a first fluid and an outlet configured to discharge the first fluid. The heat exchanger may further have at least one passageway configured to conduct the first fluid from the inlet to the outlet. The at least one passageway may be composed of a graphite foam and a layer of graphite material on the exterior of the graphite foam. The layer of graphite material may form at least a partial barrier between the first fluid and a second fluid external to the at least one passageway.

  15. Extensions to the Dynamic Aerospace Vehicle Exchange Markup Language

    Science.gov (United States)

    Brian, Geoffrey J.; Jackson, E. Bruce

    2011-01-01

    The Dynamic Aerospace Vehicle Exchange Markup Language (DAVE-ML) is a syntactical language for exchanging flight vehicle dynamic model data. It provides a framework for encoding entire flight vehicle dynamic model data packages for exchange and/or long-term archiving. Version 2.0.1 of DAVE-ML provides much of the functionality envisioned for exchanging aerospace vehicle data; however, it is limited in only supporting scalar time-independent data. Additional functionality is required to support vector and matrix data, abstracting sub-system models, detailing dynamics system models (both discrete and continuous), and defining a dynamic data format (such as time sequenced data) for validation of dynamics system models and vehicle simulation packages. Extensions to DAVE-ML have been proposed to manage data as vectors and n-dimensional matrices, and record dynamic data in a compatible form. These capabilities will improve the clarity of data being exchanged, simplify the naming of parameters, and permit static and dynamic data to be stored using a common syntax within a single file; thereby enhancing the framework provided by DAVE-ML for exchanging entire flight vehicle dynamic simulation models.

  16. Simple full micromagnetic model of exchange bias behavior in ferro/antiferromagnetic layered structures (abstract)

    Science.gov (United States)

    Koon, Norman C.

    1997-04-01

    It is shown using full micromagnetic relaxation calculations that exchange bias behavior is predicted for single-crystal ferro/antiferromagnetic layers with a fully compensated interface. The particular example most fully studied has a bcc/bct lattice structure with a fully compensated (110) interface plane. Only bilinear Heisenberg exchange was assumed, with anisotropy only in the antiferromagnet. In spite of the intuitive notion that exchange coupling between a ferromagnet and an antiferromagnet across a fully compensated plane of the antiferromagnet should be zero, we find strong coupling, comparable to the bilinear exchange, with a 90° angle between the ferromagnetic and antiferromagnetic axes of layers far from the interface in absence of an applied field. Even though the 90° coupling has characteristics resembling "biquadratic" exchange, it originates entirely from frustrated bilinear exchange. The development of exchange bias is found to originate from the formation of a domain wall in the antiferromagnet via the strong 90° exchange coupling and pinning of the wall by the magnetocrystalline anisotropy in the antiferromagnet. Because the large demagnetizing factor of the ferromagnet tends to confine its magnetization to the plane, the exchange bias is found to depend mainly on the strength and the symmetry of the in-plane component of anisotropy. Although little effort was made to analyze specific systems, the model reproduces many of the qualitative features observed in real exchange bias systems and gives reasonable semiquantitative estimates for the bias field when exchange and anisotropy values consistent with real systems are used.

  17. Vitrification process for the volume reduction and stabilization of organic resins

    International Nuclear Information System (INIS)

    Buelt, J.L.

    1982-10-01

    Pacific Northwest Laboratory has completed a series of experimental tests sponsored by the US Department of Energy (DOE) to determine the feasibility of incinerating and vitrifying organic ion-exchange resins in a single-step process. The resins used in this study were identical to those used for decontaminating auxiliary building water at the Three Mile Island (TMI) Unit 2 reactor. The primarily organic resins were loaded with nonradioactive isotopes of cesium and strontium for processing in a pilot-scale, joule-heated glass melter modified to support resin combustion. The feasibility tests demonstrated an average process rate of 3.0 kg/h. Based on this rate, if 50 organic resin liners were vitrified in a six-month campaign, a melter 2.5 times the size of the pilot scale unit would be adequate. A maximum achievable volume reduction of 91% was demonstrated in these tests

  18. Marriage exchanges, seed exchanges, and the dynamics of manioc diversity.

    Science.gov (United States)

    Delêtre, Marc; McKey, Doyle B; Hodkinson, Trevor R

    2011-11-08

    The conservation of crop genetic resources requires understanding the different variables-cultural, social, and economic-that impinge on crop diversity. In small-scale farming systems, seed exchanges represent a key mechanism in the dynamics of crop genetic diversity, and analyzing the rules that structure social networks of seed exchange between farmer communities can help decipher patterns of crop genetic diversity. Using a combination of ethnobotanical and molecular genetic approaches, we investigated the relationships between regional patterns of manioc genetic diversity in Gabon and local networks of seed exchange. Spatially explicit Bayesian clustering methods showed that geographical discontinuities of manioc genetic diversity mirror major ethnolinguistic boundaries, with a southern matrilineal domain characterized by high levels of varietal diversity and a northern patrilineal domain characterized by low varietal diversity. Borrowing concepts from anthropology--kinship, bridewealth, and filiation--we analyzed the relationships between marriage exchanges and seed exchange networks in patrilineal and matrilineal societies. We demonstrate that, by defining marriage prohibitions, kinship systems structure social networks of exchange between farmer communities and influence the movement of seeds in metapopulations, shaping crop diversity at local and regional levels.

  19. Marriage exchanges, seed exchanges, and the dynamics of manioc diversity

    Science.gov (United States)

    Delêtre, Marc; McKey, Doyle B.; Hodkinson, Trevor R.

    2011-01-01

    The conservation of crop genetic resources requires understanding the different variables—cultural, social, and economic—that impinge on crop diversity. In small-scale farming systems, seed exchanges represent a key mechanism in the dynamics of crop genetic diversity, and analyzing the rules that structure social networks of seed exchange between farmer communities can help decipher patterns of crop genetic diversity. Using a combination of ethnobotanical and molecular genetic approaches, we investigated the relationships between regional patterns of manioc genetic diversity in Gabon and local networks of seed exchange. Spatially explicit Bayesian clustering methods showed that geographical discontinuities of manioc genetic diversity mirror major ethnolinguistic boundaries, with a southern matrilineal domain characterized by high levels of varietal diversity and a northern patrilineal domain characterized by low varietal diversity. Borrowing concepts from anthropology—kinship, bridewealth, and filiation—we analyzed the relationships between marriage exchanges and seed exchange networks in patrilineal and matrilineal societies. We demonstrate that, by defining marriage prohibitions, kinship systems structure social networks of exchange between farmer communities and influence the movement of seeds in metapopulations, shaping crop diversity at local and regional levels. PMID:22042843

  20. THE IMPLICATIONS OF VARYING EXCHANGE RATES FOR THE INTERNATIONAL TRADE

    Directory of Open Access Journals (Sweden)

    Sandu Carmen

    2011-07-01

    Full Text Available The benefit of international trade is a more efficient employment of the productive forces of the world. (John Stuart Mill The exchange rate is a primary factor that influences economy. This instrument is used by some countries in order to improve the lack of balance caused as a result of the financial crisis felt in many countries considered by then infallible. The negative effects of the financial crisis can also be found in the decreased volume of commodities involved in international trade exchanges, as a consequence of modified prices and decreased offer. The globalizing trend leads to a constant expansion of exchanges between countries and to the consolidation of international cooperation. Except that economic interdependence generates an increased risk under the influence of economic, financial, monetary or political factors. The currency risk can generate either a gain or loss during foreign trade operations. The long period of RON depreciation made possible the entry of Romanian products on the international markets due to their prices. Sheltered by the gain generated by the evolution of the exchange rate, most of the exporters were not concerned by the increase of product competitiveness or by avoiding the currency risk. The fact that, for many years, the evolution of the exchange rate generated substantial losses for the exporters shows that risk coverage in Romania is, in most cases, a purely theoretical concept.