WorldWideScience

Sample records for single tooth shape

  1. Complex single-tooth restorations.

    Science.gov (United States)

    Trushkowsky, Richard D; Burgess, John O

    2002-04-01

    There are many options for restoring the decimated dentition. [43] Excellent results can be obtained with many of the materials currently available. The restorative option will depend on the size and location of the lesion, adequate isolation for adhesive restorations, caries rate, the patient's age, the aesthetic needs of the patient, occlusal habits, maintenance of maximum tooth structure, the skill of the dentist, and the longevity desired for the restoration. Amalgam is a cost-effective material, and when used properly, it can provide many years of service. Aesthetic demands, the desire to strengthen teeth, [44] and concern about the safety of mercury in amalgam have increased the use of direct composites, ceramic material, and indirect composites. The main drawback with these materials, however, is their increased technique sensitivity and concerns about their longevity. Gold continues to be a cost-effective and predictable material if placed properly. Full-coverage gold or porcelain fused to metal provides long-term predictability but is more destructive and not as aesthetically appealing. The wide varieties of materials available provide both a challenge and an opportunity to place the most effective material for a particular patient. A thorough understanding of the available materials and their appropriate use is needed to achieve a long-lasting restoration that serves the patient's needs.

  2. The development of complex tooth shape in reptiles

    Directory of Open Access Journals (Sweden)

    Oldrich eZahradnicek

    2014-02-01

    Full Text Available Reptiles have a diverse array of tooth shapes, from simple unicuspid to complex multicuspid teeth, reflecting functional adaptation to a variety of diets and eating styles. In addition to cusps, often complex longitudinal labial and lingual enamel crests are widespread and contribute to the final shape of reptile teeth. The simplest shaped unicuspid teeth have been found in piscivorous or carnivorous ancestors of recent diapsid reptiles and they are also present in some extant carnivores such as crocodiles and snakes. However, the ancestral tooth shape for squamate reptiles is thought to be bicuspid, indicating an insectivorous diet. The development of bicuspid teeth in lizards has recently been published, indicating that the mechanisms used to create cusps and crests are very distinct from those that shape cusps in mammals. Here, we introduce the large variety of tooth shapes found in lizards and compare the morphology and development of bicuspid, tricuspid and pentacuspid teeth, with the aim of understanding how such tooth shapes are generated. Next, we discuss whether the processes used to form such morphologies are conserved between divergent lizards and whether the underlying mechanisms share similarities with those of mammals. In particular, we will focus on the complex teeth of the chameleon, gecko, varanus and anole lizards using SEM and histology to compare the tooth crown morphology and embryonic development.

  3. Endodontic therapy or single tooth implant? A systematic review.

    Science.gov (United States)

    Torabinejad, Mahmoud; Lozada, Jaime; Puterman, Israel; White, Shane N

    2008-06-01

    Should a tooth with pulpal involvement be saved through endodontic therapy, or extracted and replaced with a single tooth implant? Within the limitations of the existing literature, this systematic review of treatment outcomes found that initial endodontic treatment had a high long-term survival rate, equivalent to replacement of a missing tooth with an implant-supported restoration. Single tooth implants should be considered as the first treatment option for patients requiring extraction and tooth replacement.

  4. Guided tissue healing for single-tooth implants.

    Science.gov (United States)

    Cobb, G W; Reeves, G W; Duncan, J D

    1999-06-01

    The emergence profile of a single-tooth implant abutment has a significant effect on the esthetics of the final restoration. Most healing abutments are cylindrical, unlike the nonround contours of the natural teeth being replaced. The resulting peri-implant sulcus is round rather than having the correct anatomic cross-sectional shape. This disparity may compromise the ideal emergence profile of the final restoration. This article presents a technique in which a custom abutment and provisional crown or the definitive restoration can be placed at second-stage surgery to guide tissue healing to optimum form and esthetics.

  5. A radiological study on the tooth shape anomaly

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Karp Shik [Dept. of Oral Radiology, College of Dentistry, Kyungpook National University, Daegu (Korea, Republic of)

    1994-02-15

    The purpose of this study was to evaluate the prevalence and distribution according to the types of tooth shape anomalies in permanent teeth of 6,082 persons by means of analysis of the full mouth periapical radiographs. And the following results were obtained ; 1. Among tooth shape anomalies, the highest incidence was observed on dilaceration (20.14%), followed by dens invaginatus (3.02%), peg lateralis (1.48%), taurodontism (0.34%), dens evaginatus (0.33%), talon cusp (0.20%), fusion (0.07%) and gemination (0%) in descending order of frequency. 2. Peg lateralis, dens invaginatus and dilaceration occurred more prevalent in females, and other types of tooth shape anomalies occurred more prevalent in males. 3. Dens evaginatus and taurodontism occurred with bilateral tendency, but other anomalies occurred with unilateral tendency. 4. As to the involved teeth, maxillary lateral incisors were the most frequently involved teeth on peg lateralis, dens invaginatus and talon cusp. And the mandibular premolars were the most frequently involved teeth on dens evaginatus, the maxillary first molars were on taurodontism, the maxillary second premolars were on dilaceration, and the mandibular incisors and canines were on fusion.

  6. A radiological study on the tooth shape anomaly

    International Nuclear Information System (INIS)

    Choi, Karp Shik

    1994-01-01

    The purpose of this study was to evaluate the prevalence and distribution according to the types of tooth shape anomalies in permanent teeth of 6,082 persons by means of analysis of the full mouth periapical radiographs. And the following results were obtained ; 1. Among tooth shape anomalies, the highest incidence was observed on dilaceration (20.14%), followed by dens invaginatus (3.02%), peg lateralis (1.48%), taurodontism (0.34%), dens evaginatus (0.33%), talon cusp (0.20%), fusion (0.07%) and gemination (0%) in descending order of frequency. 2. Peg lateralis, dens invaginatus and dilaceration occurred more prevalent in females, and other types of tooth shape anomalies occurred more prevalent in males. 3. Dens evaginatus and taurodontism occurred with bilateral tendency, but other anomalies occurred with unilateral tendency. 4. As to the involved teeth, maxillary lateral incisors were the most frequently involved teeth on peg lateralis, dens invaginatus and talon cusp. And the mandibular premolars were the most frequently involved teeth on dens evaginatus, the maxillary first molars were on taurodontism, the maxillary second premolars were on dilaceration, and the mandibular incisors and canines were on fusion.

  7. Fracture resistance of single-tooth implant-supported

    OpenAIRE

    Piloto, P.A.G.; Piloto, Joana F.

    2014-01-01

    The purpose of this study is to identify and compare the fracture behaviour of the ceramic used in a single-tooth implant-supported. This type of prosthesis is mainly used when a single tooth replacement is needed. Two different materials are tested for the abutment (ceramic and titanium), assuming fully connection to the crown. The implant is made of Titanium. The numerical simulations used the concept of continuous damage mechanics to predict crack pattern when loading the tooth in the vert...

  8. Minimizing tooth bending stress in spur gears with simplified shapes of fillet and tool shape determination

    DEFF Research Database (Denmark)

    Pedersen, Niels Leergaard

    2015-01-01

    by different standards, with the ISO standard probably being the most common one. Gears are manufactured using two principally different tools: rack tools and gear tools. In this work, the bending stress of involute teeth is minimized by shape optimization made directly on the final gear. This optimized shape...... is then used to find the cutting tool (the gear envelope) that can create this optimized gear shape.A simple but sufficiently flexible root parameterization is applied and emphasis is put on the importance of separating the shape parameterization from the finite element analysis of stresses. Large improvements......The strength of a gear is typically defined relative to durability (pitting) and load capacity (tooth-breakage). Tooth-breakage is controlled by the root shape and this gear part can be designed because there is no contact between gear pairs here. The shape of gears is generally defined...

  9. Patient Discomfort Following Single-Tooth Implant Placement

    DEFF Research Database (Denmark)

    Spin-Neto, Rubens; Pontes, Ana Emília Farias; Wenzel, Ann

    2014-01-01

    Aims: Evaluate postoperative discomfort (pain, bleeding and swelling) in single-tooth implant patients submitted to immediate or conventional tooth restoration together with assessment of treatment time. Methods: Twenty-four patients who received single-tooth maxillary dental implants were randomly...... assigned to an IR (Immediate Restoration) or CR (Conventional Restoration) group. In IR, an implant was inserted and a provisional tooth crown was delivered within the same session, while in CR it was delivered three months after implantation. Pain (first three days), bleeding (first day) and swelling...

  10. Flapless single-tooth immediate implant placement.

    Science.gov (United States)

    de Carvalho, Breno Carnevalli Franco; de Carvalho, Elaine Manso Oliveira Franco; Consani, Rafael Leonardo Xediek

    2013-01-01

    This 15-year prospective study evaluated the success rate and preservation of the gingival margin of single implants placed in a flapless procedure loaded immediately after extraction or after a healing period. Immediate flapless implant placement was performed in patients who fulfilled specified inclusion criteria. Implants were either immediately restored with a provisional crown or left unloaded (received healing abutment only). Implant success and gingival margin levels were evaluated after implant placement and after 1 to 15 years. A total of 305 healthy nonsmoking subjects (90 men, 215 women) were treated with 430 immediate implants during a 15-year period (December 1994 to December 2009) and monitored for 1 to 15 years. Two hundred seventy-five implants received an immediate provisional crown, and 155 received a healing abutment. The implant survival rate was 93.03% (± 3.74%). The immediate provisional helped to maintain the original gingival margin, although the implant survival rate was higher for implants that were not immediately restored (96.78%) than for the implants that were immediately restored with a provisional (90.9%). This 15-year prospective study showed a favorable implant success rate related to the flapless immediate implant placement protocol with healing abutment placement or an immediate provisional crown to replace a single missing tooth.

  11. Factors associated with implant recommendation for single-tooth replacement.

    Science.gov (United States)

    Al-Shammari, Khalaf F; Al-Ansari, Jassem M; Al-Khabbaz, Areej K; Nociti, Francisco H; Wang, Hom-Lay

    2005-06-01

    The use of dental implants for single-tooth replacement has been established as a predictable treatment option; yet, limited data are available as to how frequently this option is recommended to patients. The aim of the present study was to examine the frequency of implant recommendation by general dental practitioners after single-tooth extraction and factors influencing their decision to recommend an implant. All single-tooth extractions performed in 26 general dental practice clinics in Kuwait over a 30-day period were examined. Dentists in these centers used the study form to record demographic data, the type of tooth extracted, reason for extraction, and replacement options presented to the patients. Univariate and logistic regression analyses were used to examine associations between background factors and decisions to recommend implant therapy. A total of 1367 patients (mean age, 37.9 +/- 11.8 years) had an extraction of one tooth during the study period. Forty-three patients were offered implants as a replacement option (3.3% of the total sample; 8.6% of patients who were offered tooth replacement options). Factors associated significantly with the recommendation of an implant by Kuwaiti dentists to their patients included younger age, regular dental maintenance visits, and adequate oral hygiene practices (P single-tooth replacement in the present sample of dentists was low. Factors associated significantly with dentist recommendation of an implant for single-tooth replacement included age, history of dental maintenance, and oral hygiene practices.

  12. Tactile sensibility of single-tooth implants and natural teeth.

    Science.gov (United States)

    Enkling, Norbert; Nicolay, Claudia; Utz, Karl-Heinz; Jöhren, Peter; Wahl, Gerhard; Mericske-Stern, Regina

    2007-04-01

    The purpose of this randomized split-mouth clinical trial was to determine the active tactile sensibility between single-tooth implants and opposing natural teeth and to compare it with the tactile sensibility of pairs of natural teeth on the contralateral side in the same mouth (intraindividual comparison). The hypothesis was that the active tactile sensibilities of the implant side and control side are equivalent. Sixty two subjects (n=36 from Bonn, n=26 from Bern) with single-tooth implants (22 anterior and 40 posterior dental implants) were asked to bite on narrow copper foil strips varying in thickness (5-200 microm) and to decide whether or not they were able to identify a foreign body between their teeth. Active tactile sensibility was defined as the 50% threshold of correct answers estimated by means of the Weibull distribution. The results obtained for the interocclusal perception sensibility differed between subjects far more than they differed between natural teeth and implants in the same individual [implant/natural tooth: 16.7+/-11.3 microm (0.6-53.1 microm); natural tooth/natural tooth: 14.3+/-10.6 microm (0.5-68.2 microm)]. The intraindividual differences only amounted to a mean value of 2.4+/-9.4 microm (-15.1 to 27.5 microm). The result of our statistical calculations showed that the active tactile sensibility of single-tooth implants, both in the anterior and posterior region of the mouth, in combination with a natural opposing tooth is similar to that of pairs of opposing natural teeth (double t-test, equivalence margin: +/-8 microm, P80%). Hence, the implants could be integrated in the stomatognathic control circuit.

  13. An alternative method for restoring single-tooth implants.

    Science.gov (United States)

    McArdle, B F; Clarizio, L F

    2001-09-01

    Having laboratory technicians prepare soft-tissue casts and implant abutments with or without concomitant removable temporary prostheses during the restorative phase of single-tooth replacement is an accepted practice. It can, however, result in functional and esthetic intraoral discrepancies. Single-tooth implants can be restored with crowns (like those for natural teeth) fabricated at a dental laboratory on casts obtained from final impressions of prepared implant abutments. In the case reported, the restorative dentist restored the patient's single-tooth implant after taking a transfer impression. He constructed a cast simulating the peri-implant soft tissue with final impression material and prepared the abutment on this model. His dental assistant then fabricated a fixed provisional restoration on the prepared abutment. At the patient's next visit, the dentist torqued the prepared abutment onto the implant, took a final impression and inserted the provisional restoration. A crown was made conventionally at the dental laboratory and cemented in place at the following visit. This alternative method for restoring single-tooth implants enhances esthetics by more accurately simulating marginal gingival architecture. It also improves function by preloading the implant through fixed temporization after the dentist, rather than the laboratory technician, prepares the abutment to the dentist's preferred contours.

  14. Prospective evaluation of immediate and delayed provisional single tooth restorations.

    Science.gov (United States)

    Block, Michael S; Mercante, Donald E; Lirette, Denise; Mohamed, Waheed; Ryser, Mark; Castellon, Paulino

    2009-11-01

    The purpose of this study was 2-fold: to determine whether there is a significant difference in the hard and soft tissue response comparing immediate with delayed implant placement after tooth removal, with immediate provisionalization, in maxillary anterior sites; and to determine and compare the crestal bone levels as the primary endpoint variable for implants placed and immediately temporized in extraction sites, to implants placed into extraction sites after the extraction site has been grafted and healed for 4 months, all immediately restored with an anatomic provisional restoration. This aim was to be evaluated by measuring crestal bone levels on standardized digital radiographs of the implants, using implant threads as a monitor of magnification and a pre-extraction reference. Secondary endpoint variables include soft tissue measures compared with method. A total of 76 patients were recruited and randomized into treatment groups. Group 1 had a maxillary tooth (premolar, canine, lateral or central incisor) removed, with immediate socket grafting, followed by implant placement and provisionalization 4 months later with a single tooth. Group 2 had immediate implant placement and provisionalization. Standardized radiograph holders were used to expose digital radiographs every 6 months from baseline to up to 2 years restored. Soft tissue measures were made from standardized reference points. Data collected were analyzed by a statistician to test the hypotheses. A total of 55 patients completed their follow-up. Twenty-one patients were lost to follow-up because of implant loss (n = 5), 1 treated out of protocol because of labial bone loss found at the time of tooth removal (n = 1), geographic relocation (n = 11), dropped for noncompliance (n = 3), or medical problems (n = 1). The analyses showed no significant differences between groups in implant integration or crestal interdental bone movement on either the implant or the adjacent tooth. The bone level on the

  15. Single-tooth replacement: factors affecting different prosthetic treatment modalities.

    Science.gov (United States)

    Al-Quran, Firas A; Al-Ghalayini, Raed F; Al-Zu'bi, Bashar N

    2011-12-21

    The choice between several treatment options for replacing a single missing tooth is influenced by clinical, dentist- and patient-immanent factors. This study aimed to determine the patient factors that would affect the treatment decision to replace a single missing tooth and to assess the satisfaction with several options. 200 volunteers involved (121 females and 79 males) divided into four groups, Group A: consisted of patients with conventional fixed partial dentures or patients with resin bonded fixed partial dentures. Group B: consisted of patients who received removable partial dentures while Group C: consisted of patients who received a single implant supported crown, and a control group D: consisted of patients who received no treatment. Data were collected using a questionnaire. The highest percentage of males within groups (58%) was within the removable prostheses category. The majority of the subjects in the study reported that the main reason for replacing a missing tooth was for esthetic and function. Most important factor affecting the choice between treatment modalities was damaging the neighboring teeth. Pain, post operative sensitivity and dental phobia were important factors in choosing the prosthesis type and affected the control group patients not to have any treatment. The highest satisfaction percentage among groups studied was recorded for dental implants then FPD groups, while the least percentage were in both the control and RPD groups, for all aspects of function, esthetic and speech efficiency. The final choice between FPD, RPD and implant depended on several factors which affected the decision making; among these is cost and patients' awareness of the different treatment options.

  16. Single-tooth replacement: factors affecting different prosthetic treatment modalities

    Directory of Open Access Journals (Sweden)

    Al-Quran Firas A

    2011-12-01

    Full Text Available Abstract Background The choice between several treatment options for replacing a single missing tooth is influenced by clinical, dentist- and patient-immanent factors. This study aimed to determine the patient factors that would affect the treatment decision to replace a single missing tooth and to assess the satisfaction with several options. Method 200 volunteers involved (121 females and 79 males divided into four groups, Group A: consisted of patients with conventional fixed partial dentures or patients with resin bonded fixed partial dentures. Group B: consisted of patients who received removable partial dentures while Group C: consisted of patients who received a single implant supported crown, and a control group D: consisted of patients who received no treatment. Data were collected using a questionnaire. Results The highest percentage of males within groups (58% was within the removable prostheses category. The majority of the subjects in the study reported that the main reason for replacing a missing tooth was for esthetic and function. Most important factor affecting the choice between treatment modalities was damaging the neighboring teeth. Pain, post operative sensitivity and dental phobia were important factors in choosing the prosthesis type and affected the control group patients not to have any treatment. The highest satisfaction percentage among groups studied was recorded for dental implants then FPD groups, while the least percentage were in both the control and RPD groups, for all aspects of function, esthetic and speech efficiency. Conclusions The final choice between FPD, RPD and implant depended on several factors which affected the decision making; among these is cost and patients' awareness of the different treatment options.

  17. A saw-tooth plasma actuator for film cooling efficiency enhancement of a shaped hole

    Science.gov (United States)

    Li, Guozhan; Yu, Jianyang; Liu, Huaping; Chen, Fu; Song, Yanping

    2017-08-01

    This paper reports the large eddy simulations of the effects of a saw-tooth plasma actuator and the laidback fan-shaped hole on the film cooling flow characteristics, and the numerical results are compared with a corresponding standard configuration (cylindrical hole without the saw-tooth plasma actuator). For this numerical research, the saw-tooth plasma actuator is installed just downstream of the cooling hole and a phenomenological plasma model is employed to provide the 3D plasma force vectors. The results show that thanks to the downward force and the momentum injection effect of the saw-tooth plasma actuator, the cold jet comes closer to the wall surface and extends further downstream. The saw-tooth plasma actuator also induces a new pair of vortex which weakens the strength of the counter-rotating vortex pair (CRVP) and entrains the coolant towards the wall, and thus the diffusion of the cold jet in the crossflow is suppressed. Furthermore, the laidback fan-shaped hole reduces the vertical jet velocity causing the disappearance of downstream spiral separation node vortices, this compensates for the deficiency of the saw-tooth plasma actuator. Both effects of the laidback fan-shaped hole and the saw-tooth plasma actuator effectively control the development of the CRVP whose size and strength are smaller than those of the anti-counter rotating vortex pair in the far field, thus the centerline and the spanwise-averaged film cooling efficiency are enhanced. The average film cooling efficiency is the biggest in the Fan-Dc = 1 case, which is 80% bigger than that in the Fan-Dc = 0 case and 288% bigger than that in the Cyl-Dc = 0 case.

  18. Triple dens invaginatus in a single tooth: Rarest of rare case report.

    Science.gov (United States)

    Chhina, Amandeep; Chhina, Kamalpreet; Kaushal, Nitin; Walia, Ira

    2017-01-01

    Dens invaginatus is a rare malformation affecting the teeth. The teeth that are most commonly affected are the permanent maxillary lateral incisors. The mandibular posterior teeth are rarely affected by dens invaginatus. In most of the cases, a single dens invaginatus is seen affecting the tooth. Cases of double dens invaginatus affecting a single tooth are rare, and those of triple dens invaginatus in a single tooth are even rarer. Here, we present a case of a 14-year-old where three dens invaginatus were seen in the mandibular second premolar. This is the fourth case of three dens invaginatus in a single tooth as only three have been reported previously.

  19. Reconstruction of pseudo three-dimensional dental image from dental panoramic radiograph and tooth surface shape

    International Nuclear Information System (INIS)

    Imura, Masataka; Kuroda, Yoshihiro; Oshiro, Osamu; Kuroda, Tomohiro; Kagiyama, Yoshiyuki; Yagi, Masakazu; Takada, Kenji; Azuma, Hiroko

    2010-01-01

    Three-dimensional volume data set is useful for diagnosis in dental treatments. However, to obtain three-dimensional images of a dental arch in general dental clinics is difficult. In this paper, we propose a method to reconstruct pseudo three-dimensional dental images from a dental panoramic radiograph and a tooth surface shape which can be obtained from three dimensional shape measurement of a dental impression. The proposed method finds an appropriate curved surface on which the dental panoramic radiograph is mapped by comparing a virtual panoramic image made from a tooth surface shape to a real panoramic radiograph. The developed pseudo three-dimensional dental images give clear impression of patient's dental condition. (author)

  20. Single-tooth replacement by osseointegrated Astra Tech dental implants: a 2-year report

    DEFF Research Database (Denmark)

    Karlsson, U; Gotfredsen, K; Olsson, C

    1998-01-01

    This study presents the outcome of single-tooth restorations supported by Astra Tech single-tooth implants followed for 2 years. Forty-seven implants were placed in the same number of patients. Forty-three patients attended the second recall visit, and none of the evaluated implants have been...

  1. The autogenous immediate implant supported single-tooth restoration: a 5-year follow-up.

    Science.gov (United States)

    Castelnuovo, Jacopo; Sönmez, Ayse Burçin

    2012-01-01

    When replacing a missing tooth in the esthetic zone, the implant supported single tooth restoration can result in a very natural and pleasing solution for the patient, being also a conservative procedure that preserves the adjacent remaining dentition. Immediate implant placement with an immediate provisional crown can avoid stressful and uncomfortable healing time for the patient who no longer has to wear an interim removable appliance. In selected clinical situations, excellent tooth esthetics for implant supported single tooth restorations can be achieved by using the natural extracted tooth as both provisional and final restoration. No longterm data is available today as far as the survival rate of such restorations and the predictability of such a treatment modality. This case report describes a technique for utilizing the patient's extracted tooth for the fabrication of an inconspicuous final anterior restoration, reporting a 5-year follow-up.

  2. Tooth retention through endodontic microsurgery or tooth replacement using single implants: a systematic review of treatment outcomes.

    Science.gov (United States)

    Torabinejad, Mahmoud; Landaez, Maria; Milan, Marites; Sun, Chun Xiao; Henkin, Jeffrey; Al-Ardah, Aladdin; Kattadiyil, Mathew; Bahjri, Khaled; Dehom, Salem; Cortez, Elisa; White, Shane N

    2015-01-01

    Clinicians are regularly confronted with difficult choices. Should a tooth that has not healed through nonsurgical root canal treatment be treated through endodontic microsurgery or be replaced using a single implant? Acquiring complete, unbiased information to help clinicians and their patients make these choices requires a systematic review of the literature on treatment outcomes. The purpose of this systematic review was to compare the outcomes of tooth retention through endodontic microsurgery to tooth replacement using an implant supported single crown. Searches performed in PubMed, Cochrane Library, Web of Science, and EMBASE databases were enriched by citation mining. Inclusion criteria were defined. Sentinel articles were identified and included in the final selection of studies. Weighted survival and success rates for single implants and endodontic microsurgery were calculated. The quality of the articles reporting on single implants and endodontic microsurgery was moderate. Data for single implants were much more plentiful than for endodontic microsurgery, but the endodontic microsurgery studies had a slightly higher quality rating. Single implants and endodontic microsurgery were not directly compared in the literature. Outcomes criteria were often unclear. At 4-6 years, single implants had higher survival rates than teeth treated with endodontic microsurgery. Qualitatively different success criteria precluded valid comparison of success rates. Survival rates for single implants and endodontic microsurgery were both high (higher for single implants). Appraisal was limited by a lack of direct treatment comparisons. Long-term studies with a broad range of carefully defined outcomes criteria are needed. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  3. Triple dens invaginatus in a single tooth: Rarest of rare case report

    Directory of Open Access Journals (Sweden)

    Amandeep Chhina

    2017-01-01

    Full Text Available Dens invaginatus is a rare malformation affecting the teeth. The teeth that are most commonly affected are the permanent maxillary lateral incisors. The mandibular posterior teeth are rarely affected by dens invaginatus. In most of the cases, a single dens invaginatus is seen affecting the tooth. Cases of double dens invaginatus affecting a single tooth are rare, and those of triple dens invaginatus in a single tooth are even rarer. Here, we present a case of a 14-year-old where three dens invaginatus were seen in the mandibular second premolar. This is the fourth case of three dens invaginatus in a single tooth as only three have been reported previously.

  4. Immediate provisional restoration of postextraction implants for maxillary single-tooth replacement.

    Science.gov (United States)

    Ferrara, Alberto; Galli, Carlo; Mauro, Giovanni; Macaluso, Guido Maria

    2006-08-01

    The timing of implant placement and loading following tooth extraction has recently undergone substantial reconsideration. The authors tested a protocol of immediate loading of single implants placed at the time of tooth extraction in a consecutive case series. Thirty-three patients received a single implant-supported crown to replace a maxillary anterior tooth at the time of extraction. Regular recalls were planned for the following 4 years. One implant did not integrate, and another became unstable secondary to facial trauma. Overall patient satisfaction and clinical and radiographic parameters were good.

  5. Coexistence of two talon cusps and two dens invaginatus in a single tooth with associated radicular cyst-a case report and review of literature.

    Science.gov (United States)

    Kasat, Vikrant O; Singh, Mukund; Saluja, Harish; Ladda, Ruchi

    2014-10-01

    Talon cusp (TC) and dens invaginatus (DI) are relatively rare developmental anomalies which affect the shape of teeth. TC is an additional cusp that projects predominately from the lingual surface of anterior teeth. DI is a deep surface invagination of the crown or root which is commonly detected on routine radiographic examination. Both of these anomalies are observed more frequently in permanent maxillary lateral incisor. Isolated cases of single TC and DI are extensively reported in dental literature. Occasionally two talon cusps (TCs) in the same tooth as well as double and triple invaginations in one tooth are reported separately. Coexistence of these two anomalies in a single tooth is considered extremely rare, but still there are few reported cases. However, coexistence of two TCs and double DI in a single tooth is not reported till date. We hereby report the first case of coexistence of two TCs and double DI in a single tooth of a 23 year old female and use of platelet-rich fibrin (PRF) in the management of associated radicular cyst. Also, literature on coexistence of these two anomalies in a single tooth is reviewed. Key words:Coexistence, dens invaginatus, radicular cyst, talon cusp.

  6. Esthetic evaluation of single-tooth implants in the anterior mandible.

    Science.gov (United States)

    Hof, Markus; Tepper, Gabor; Koller, Barbara; Krainhöfner, Martin; Watzek, Georg; Pommer, Bernhard

    2014-09-01

    Single-tooth replacement of anterior mandibular teeth is frequently complicated by insufficient bucco-lingual bone width and limited mesio-distal space available for implant placement. The aim of the present study was to assess implant esthetics in the partially edentulous anterior mandible. Esthetic evaluation of 43 anterior mandibular single-tooth implants in 15 women and 28 men was performed using esthetic indices (PES = Pink Esthetic Score, PI = Papilla Index, SES = Subjective Esthetic Score) as well as subjective patients' Visual Analogue Scale (VAS) ratings. Clinical and radiological parameters (implant and crown dimensions, pocket depth, bleeding on probing, plaque, keratinized mucosa, marginal bone level, and distance to adjacent teeth) were tested for influence. Implant esthetics were judged satisfactory (PES ≤10) in 42% of implants compared with a patient satisfaction rate of 87%. Correlation between objective indices (PES/PI: rs  = 0.62, PES/SES: rs  = -0.73, PI/SES: rs  = -0.48) was highly significant (P ≤ 0.001); however, no association to subjective patients' ratings could be observed. Type of prosthetic restoration (single crown vs. tulip-shaped double crowns), mesio-distal crown width as well as anatomic crown length significantly affected esthetic scores. Patients' judgment, by contrast, could not be associated to any prognostic factor. Subjective patient satisfaction with implant esthetics in the partially edentulous anterior mandible is high, however, remains hard to predict or objectively quantify. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Patient Discomfort Following Single-Tooth Implant Placement

    DEFF Research Database (Denmark)

    Spin-Neto, Rubens; Pontes, Ana Emília Farias; Wenzel, Ann

    2014-01-01

    assigned to an IR (Immediate Restoration) or CR (Conventional Restoration) group. In IR, an implant was inserted and a provisional tooth crown was delivered within the same session, while in CR it was delivered three months after implantation. Pain (first three days), bleeding (first day) and swelling...

  8. A 10-Year Prospective Study of Single Tooth Implants Placed in the Anterior Maxilla

    DEFF Research Database (Denmark)

    Gotfredsen, Klaus

    2012-01-01

    Purpose: The aim of the study was to evaluate the biological and technical outcomes of early and delayed placed single tooth implants after 10 years of follow-up. Materials and Methods: Twenty consecutive patients who needed a single tooth replacement in the anterior maxilla were included...... in this study. Ten implants were placed with an early placement protocol, that is, 4 weeks after tooth extraction, whereas the other 10 implants were placed with a conventional delayed placement protocol, for example, 12 weeks after tooth extraction. At the baseline and at the annual re-examinations, pain from...... and delayed implant placement. Patient satisfaction with the implant-supported single crowns reduced with time....

  9. Endodontic treatment options after unsuccessful initial root canal treatment: Alternatives to single-tooth implants.

    Science.gov (United States)

    Torabinejad, Mahmoud; White, Shane N

    2016-03-01

    Initial root canal treatment is highly successful, appreciated by patients, and cost-effective, but failures occur. Should a tooth with unsuccessful initial root canal treatment be treated by means of other endodontic procedures or be replaced by a single-tooth implant? Results from systematic reviews of the outcomes of nonsurgical retreatment, apical surgery, replantation, and autotransplantation show high tooth survival rates. Nonsurgical retreatment generally is prioritized before surgical endodontic treatment. Microsurgical endodontic treatment is superior to traditional surgical endodontic treatment and has high survival rates. Intentional replantation remains a viable alternative to extraction. Autotransplantation has a place, particularly in growing patients with an appropriate donor tooth. Single-tooth implants have higher survival rates, but the natural state has intrinsic value. The first-line treatment option after failure of initial root canal treatment is nonsurgical retreatment. Endodontic surgery, intentional replantation, and autotransplantation should be considered before extraction and replacement by a single-tooth implant. Comprehensive case assessment, evaluation of all endodontic options, and risk assessment for caries and periodontal disease are always necessary when choosing the optimal treatment for a patient when initial root canal treatment has failed to heal. Copyright © 2016 American Dental Association. Published by Elsevier Inc. All rights reserved.

  10. Innovative Single-Tooth Replacement with an Individual Root-Analog Hybrid Implant in the Esthetic Zone: Case Report.

    Science.gov (United States)

    Saeidi Pour, Reza; Randelzhofer, Peter; Edelhoff, Daniel; Prandtner, Otto; Rafael, Caroline Freitas; Liebermann, Anja

    The goal of this study was to explore an innovative approach to single-tooth replacement using an individually custom-fabricated, root-analog, hybrid dental implant, in the esthetic zone, to avoid the microgap and micromovements between the implant and abutment. Moreover, the use of burs to prepare the implant recipient site is not necessary in this technique, reducing the bone removal, heating, and trauma. The process requires capturing accurate root geometry through combined computer-aided design/computer-assisted manufacturing (CAD/CAM) and a three-dimensional (3D) visualization (digital volume tomography [DVT]) of the tooth in situ, which might result in reduced remodeling after insertion. A good esthetic and functional outcome was obtained. The use of a root-shaped tooth analog implant might be in selected cases a viable alternative to current threaded cylindrical and cone-shaped implants. The new concept avoids the microgap between the implant and the abutment and reduces the trauma to the tissue and bone.

  11. Immediate implant therapy in clinical practice: single-tooth replacement.

    Science.gov (United States)

    Fugazzotto, Paul A; Baker, Richard; Lightfoot, Scott

    2007-01-01

    Once viewed as an esoteric treatment option, implant therapy has demonstrated long-term predictability at least equal to that of more "conventional" treatment modalities. The continued evolution of implant surface technology and restorative options has made implant therapy the treatment modality of choice in many if not most, clinical situations. It is, therefore, only natural that the role of immediate implant therapy continues to expand. Proponents of immediate implant therapy advocate its use at the time of tooth removal or, in a partially or fully edentulous arch, to meet a variety of clinical challenges.

  12. Allometry, merism, and tooth shape of the upper deciduous M2 and permanent M1.

    Science.gov (United States)

    Bailey, Shara E; Benazzi, Stefano; Hublin, Jean-Jacques

    2014-05-01

    The aims of this study were to investigate the effect of allometry on the shape of dm(2) and M(1) crown outlines and to examine whether the trajectory and magnitude of scaling are shared between species. The sample included 160 recent Homo sapiens, 28 Upper Paleolithic H. sapiens, 10 early H. sapiens, and 33 H. neanderthalensis (Neandertal) individuals. Of these, 97 were dm(2) /M(1) pairs from the same individuals. A two-block partial least squares analysis of paired individuals revealed a significant correlation in crown shape between dm(2) and M(1) . A principal component analysis confirmed that Neandertal and H. sapiens dm(2) and M(1) shapes differ significantly and that this difference is primarily related to hypocone size and projection. Allometry accounted for a small but significant proportion of the total morphological variance. We found the magnitude of the allometric effect to be significantly stronger in Neandertals than in H. sapiens. Procrustes distances were significantly different between the two tooth classes in Neandertals, but not among H. sapiens groups. Nevertheless, we could not reject the null hypothesis that the two species share the same allometric trajectory. Although size clearly contributes to the unique shape of the Neandertal dm(2) and M(1) , the largest H. sapiens teeth do not exhibit the most Neandertal-like morphology. Hence, additional factors must contribute to the differences in dm(2) and M(1) crown shape between these two species. We suggest an investigation of the role of timing and rate of development on the shapes of the dm(2) and M(1) may provide further answers. Copyright © 2014 Wiley Periodicals, Inc.

  13. Discordant tooth agenesis and peg-shaped in a pair of monozygotic twins: Clinical and molecular study.

    Science.gov (United States)

    Antunes, Lívia Azeredo Alves; Küchler, Erika Calvano; Costa, Marcelo de Castro; Antunes, Leonardo Santos; Granjeiro, José Mauro

    2013-11-01

    The present report aimed to study an uncommon case of a pair of twins that presented a discordant dental phenotype. Family investigation, clinical, radiographic examination and molecular analysis were performed in both girls. Molecular analysis confirmed the monozygosity by deoxyribonucleic acid chip technology. One twin presented tooth agenesis in left upper lateral incisor and peg-shaped on the contra lateral side while the other twin had no dental alterations. The dental casts study employed digital caliper to compare morphological dimensions and showed alteration only in peg-shaped tooth. In conclusion, this study provide support that one or more mutated gene could cause discordances in dental phenotype in these monozygotic twins.

  14. Economic evaluation of single-tooth replacement: dental implant versus fixed partial denture.

    Science.gov (United States)

    Kim, Younhee; Park, Joo-Yeon; Park, Sun-Young; Oh, Sung-Hee; Jung, YeaJi; Kim, Ji-Min; Yoo, Soo-Yeon; Kim, Seong-Kyun

    2014-01-01

    This study assessed the cost-effectiveness from a societal perspective of a dental implant compared with a three-unit tooth-supported fixed partial denture (FPD) for the replacement of a single tooth in 2010. A decision tree was developed to estimate cost-effectiveness over a 10-year period. The survival rates of single-tooth implants and FPDs were extracted from a meta-analysis of single-arm studies. Medical costs included initial treatment costs, maintenance costs, and costs to treat complications. Patient surveys were used to obtain the costs of the initial single-tooth implant or FPD. Maintenance costs and costs to treat complications were based on surveys of seven clinical experts at dental clinics or hospitals. Transportation costs were calculated based on the number of visits for implant or FPD treatment. Patient time costs were estimated using the number of visits and time required, hourly wage, and employment rate. Future costs were discounted by 5% to convert to present values. The results of a 10-year period model showed that a single dental implant cost US $261 (clinic) to $342 (hospital) more than an FPD and had an average survival rate that was 10.4% higher. The incremental cost-effectiveness ratio was $2,514 in a clinic and $3,290 in a hospital for a prosthesis in situ for 10 years. The sensitivity analysis showed that initial treatment costs and survival rate influenced the cost-effectiveness. If the cost of an implant were reduced to 80% of the current cost, the implant would become the dominant intervention. Although the level of evidence for effectiveness is low, and some aspects of single-tooth implants or FPDs, such as satisfaction, were not considered, this study will help patients requiring single-tooth replacement to choose the best treatment option.

  15. In patients requiring single-tooth replacement, what are the outcomes of implant- as compared to tooth-supported restorations?

    Science.gov (United States)

    Salinas, Thomas J; Eckert, Steven E

    2007-01-01

    The study provides a systematic review of the literature to determine the long-term survival characteristics of single implant-supported crowns and fixed partial dentures. A search of the MEDLINE, EMBASE, and Cochrane Collaboration databases was conducted to identify articles that compared survival and success of fixed partial dentures and single implant-supported crowns. In addition to comparative cohort studies, articles that pertained specifically to single implant-supported crowns or fixed partial dentures were included in this review. Inclusion criteria for implant and fixed partial denture articles included a minimum 2-year study, primary publication in the English language, a minimum of 12 implants, implants designed to osseointegrate, and inclusion of data regarding implant and prosthetic performance. Data were analyzed using cumulative proportions of survival and success for both prosthetic types and for individual implants. Wilson score method was used to establish 95% confidence intervals for each population. The chi-square test for homogeneity was performed. The literature search failed to identify any articles that directly compared survival or success of single implant-supported restorations with fixed partial dentures. Following the search criteria, and independent analysis by reviewers, 51 articles were identified in the implant literature (agreement, 95.42%; kappa coefficient, 0.8976), and 41 were identified in the fixed partial denture literature (agreement, 90.97%; kappa coefficient, 0.7524). Pooled success of single-implant restorations at 60 months was 95.1% (CI: 92.2%-98.0%), while fixed partial dentures of all designs exhibited an 84.0% success rate (CI: 79.1%-88.9%). This systematic review of the scientific literature failed to demonstrate any direct comparative studies assessing clinical performance of single implant-supported crowns and tooth-supported fixed partial dentures. The analysis suggested differences at 60 months between survival

  16. Synthesis and ultrastructure of plate-like apatite single crystals as a model for tooth enamel

    Energy Technology Data Exchange (ETDEWEB)

    Zhuang, Zhi, E-mail: zhuang@meiji.ac.jp [Department of Applied Chemistry, School of Science and Technology, Meiji University, 1-1-1 Higashimita, Tama-ku, Kawasaki, Kanagawa 214-8571 (Japan); Yoshimura, Hideyuki, E-mail: hyoshi@isc.meiji.ac.jp [Department of Physics, School of Science and Technology, Meiji University, 1-1-1 Higashimita, Tama-ku, Kawasaki, Kanagawa 214-8571 (Japan); Aizawa, Mamoru, E-mail: mamorua@isc.meiji.ac.jp [Department of Applied Chemistry, School of Science and Technology, Meiji University, 1-1-1 Higashimita, Tama-ku, Kawasaki, Kanagawa 214-8571 (Japan)

    2013-07-01

    Hydroxyapatite (HAp) is an inorganic constituent compound of human bones and teeth, with superior biocompatibility and bioactivity characteristics. Its crystal structure is hexagonal, characterized by a(b)- and c-planes. In vertebrate long bones, HAp crystals have a c-axis orientation, while in tooth enamel, they have an a(b)-axis orientation. Many methods can be used to synthesize c-axis oriented HAp single crystals; however, to the best of our knowledge, there have been no reports on a synthesis method for a(b)-axis oriented HAp single crystals. In this study, we successfully synthesized plate-like HAp crystals at the air–liquid interface of a starting solution via an enzyme reaction of urea with urease. Crystal phase analysis and ultrastructure observations were carried out, and the results indicated that the particles were single crystals, with almost the same a(b)-axis orientation as tooth enamel. It is hoped that by utilizing their unique surface charge and atomic arrangement, the resulting particles can be used as a high-performance biomaterial, capable of adsorbing bio-related substances and a model for tooth enamel. - Highlights: ► Synthesis of plate-like hydroxyapatite crystals at air–liquid interface ► Ultrastructural analysis of plate-like hydroxyapatite crystals ► Plate-like hydroxyapatite single crystals with a high a(b)-axis orientation ► Plate-like hydroxyapatite single crystals as a model for tooth enamel.

  17. Patient satisfaction with single-tooth implant therapy in the esthetic zone

    NARCIS (Netherlands)

    den Hartog, Laurens; Meijer, Henny J. A.; Santing, Hendrik J.; Vissink, Arjan; Raghoebar, Gerry M.

    2014-01-01

    This prospective study assessed patient satisfaction before and after single-tooth implant therapy in the esthetic zone. Before implant therapy, patients wore an acrylic resin tissue-supported removable partial denture (RPD). A total of 153 patients were included. Self-administered questionnaires

  18. Single tooth immediate provisional restoration of dental implants: technique and early results.

    Science.gov (United States)

    Block, Michael; Finger, Israel; Castellon, Paulino; Lirettle, Denise

    2004-09-01

    Patients desire efficient restoration of missing teeth. Immediate provisionalization of implants at the time of placement can provide the patient with a tooth-like restoration. Our hypothesis is that preoperative fabrication of the implant abutment and provisional restoration can provide successful immediate provisionalization of implants, if specific diagnostic criteria are used for patient selection. This hypothesis is evaluated by prospectively following 74 implants thus treated for 6 months to 2 years. A technique is presented to illustrate a simple and reliable method to provisionally restore a single tooth restoration. The method involves preoperative placement of an implant analog into a model, preparation of the abutment on the model, and fabrication of a provisional crown out of occlusion. At the time of surgery, the implant is placed according to the prescription of the restorative dentist, the surgeon places the abutment and provisional crown, and the final restoration is fabricated after the implant integrates. Seventy of 74 (94.6%) restorations have been successful with up to 2-year follow-up, which is similar to single tooth implants treated using a 2-stage protocol. Single tooth immediate provisionalization implants are effective techniques when specific diagnostic criteria are used.

  19. Replacement of a single missing tooth in maxilla : factors to consider

    OpenAIRE

    Skogekker, Vegard Haug; Sørensen, Karoline; Hustad, Kyrre Aas; Skogen, Katrine Horn

    2013-01-01

    Background: In dentistry when replacing a single missing tooth in the maxilla, the choice of treatment is often between either a fixed partial denture (FPD) or a single dental implant. The challenge is to utilize relevant factors in treatment planning, achieving benefit for the patient. This article focuses on the factors that should be taken into consideration in decision-making. The investigation provides an attempted to further understand the importance of the factors studied. Method: A q...

  20. Clinical outcomes of zirconia-based implant- and tooth-supported single crowns.

    Science.gov (United States)

    Nejatidanesh, Farahnaz; Moradpoor, Hedayat; Savabi, Omid

    2016-01-01

    Zirconia-based restorations have been increasingly used on implant and teeth abutments, but the evidence about clinical outcomes of these restorations is limited. The aim of this study was to assess up to 7-year clinical outcomes of implant- and tooth-supported zirconia-based single crowns. In this retrospective study, 261 patients with 556 single crowns supported by either teeth (324) or implants (232) were examined during 3- to 7-year follow-up (mean observation of 60.70 months for tooth and 59.20 months for implant-supported crowns). California Dental Association (CDA) quality evaluation system was used to evaluate the restorations. Soft tissue status was assessed using plaque and gingival index scores, bleeding on probing, and pocket depth. Patient and professional satisfaction were evaluated by visual analog scale (VAS). The 5-year Kaplan-Meier survival probability was 98.3 and 97.3 for implant- and tooth-supported crowns, respectively. In regard to CDA rating, most of the crowns were ranked as either excellent or acceptable (99.5 %). The recorded failures were replacement of the crown due to porcelain chipping (3), implant failure (1), and teeth extraction (5). Soft tissue parameters were not affected by the restorations compare to control teeth. The VAS was high for both patients and clinicians. Zirconia-based single crowns on both tooth and implant abutments showed promising clinical performance in this up to 7-year follow-up. The zirconia-based single crowns can be used clinically for tooth- and implant-supported restorations.

  1. Discordant tooth agenesis and peg-shaped in a pair of monozygotic twins: Clinical and molecular study

    Directory of Open Access Journals (Sweden)

    Lívia Azeredo Alves Antunes

    2013-01-01

    Full Text Available The present report aimed to study an uncommon case of a pair of twins that presented a discordant dental phenotype. Family investigation, clinical, radiographic examination and molecular analysis were performed in both girls. Molecular analysis confirmed the monozygosity by deoxyribonucleic acid chip technology. One twin presented tooth agenesis in left upper lateral incisor and peg-shaped on the contra lateral side while the other twin had no dental alterations. The dental casts study employed digital caliper to compare morphological dimensions and showed alteration only in peg-shaped tooth. In conclusion, this study provide support that one or more mutated gene could cause discordances in dental phenotype in these monozygotic twins.

  2. Study on compactness of planar waveguide based integrated optic couplers using tooth shaped grating assisted geometry

    Science.gov (United States)

    Deka, Bidyut; Dutta, Aradhana; Sahu, Partha P.

    2013-11-01

    The introduction of Photonic Integrated Devices (PID) for applications in high speed optical networks providing multiple services to more number of users is indispensable as this requires large scale integration (LSI) and the miniaturization of PID device components to microscale platform has attracted immense attention from the researchers and entrepreneurs. In this paper, we present a comparative study on compactness of basic PID components using tooth shaped grating assisted (TSGA) geometry. The basic PID components such as Directional Coupler (DC), two mode interference (TMI) coupler and multimode interference (MMI) coupler have been designed using TSGA geometry in the coupling region and the coupling characteristics for the same have been estimated using a mathematical model based on sinusoidal mode simple effective index method (SM-SEIM). The dependence of modal power in the coupling region on the waveguide separation gap and coupling gap refractive index has been studied. From the estimated dependences of beat length and access waveguide length on waveguide separation gap with permissible propagation loss ~0.15 dB/cm, it has been found that the grating assisted TMI coupler (GA-TMI) is ~0.5 times lower than that of grating assisted DC (GA-DC) and ~0.44 times lower than grating assisted MMI (GA-MMI) coupler. Further, it is seen that the device length including access waveguide length of GA-MMI coupler is less than that of GA-TMI coupler and GA-DC. The SM-SEIM based numerical results are then compared with beam propagation method (BPM) results obtained by using commercially available optiBPM software.

  3. Clinical application of single-tooth replacement with ankylos implant system

    International Nuclear Information System (INIS)

    Yang Xu; Liu Xue; Zhang Heng; Deng Yan; Guo Zhaozhong; Zhang Yufeng

    2011-01-01

    Objective: To evaluate the clinical effects of Ankylos implant system to restore the loss of single-tooth. Methods: 90 cases with loss of single-tooth were selected and treated with routinely two-stage surgery. When the patients presented with deficient alveolar ridge, guided bone regeneration (GBR), osteotome sinus floor elevation, lateral antrostomy surgery with simultaneous placement of implant were applied. They were restored with platinum ceramic crown. All the implants were followed up, and the records were kept about stability of the implant and abutment, the status of surrounding soft tissue, sealability of implant abutment junction and the marginal bone lossing through X-ray checking,and satisfaction of the patients to mastication and aspect of the restorations. The follow-up time was 1-2.5 years. Results: Among the cases,one case had peri-implant inflammation, and one case had porcelain dropped. No loosening occurred in the other implants and abuments. Implant abutment junction was sealed well. The marginal bone loss 1 year after final restoration was less than 1 mm. Soft tissue surrounding implants was healthy. The satisfaction rate was 98.9% (89/90). According to standard of implant success, 88 cases were successful, the 2.5-year cumulative success rate was 97.8%, 2 cases failed, and the failure rate was 2.2 %. Conclusion: A satisfactory treatment effects could be gotten by using Ankylos implant system to restore the loss of single-tooth. (authors)

  4. Local sinus lift for single-tooth implant. I: clinical and radiographic follow-up.

    Science.gov (United States)

    Kahnberg, Karl-Erik; Wallström, Mats; Rasmusson, Lars

    2011-09-01

    For single-tooth implant replacement in the posterior maxilla, it is often necessary to do an augmentation of the alveolar process because of post-extraction resorption and include part of the maxillary sinus. The purpose of this study is to present a technique for a local sinus lift with autogenous bone in a one-stage procedure. Additionally, volume changes of the grafted area were evaluated radiographically up to 2 years. Twenty patients, 12 female and 8 males, were included in the study. Single-tooth replacement was made in the second premolar area in 7 cases and in the molar area in 13 cases. Local sinus lift and implant installation were made simultaneously. Abutment connection was made after 6 months of healing. Two years of clinical and radiographic follow-ups have been made in all patients. The survival rate was 100%. The residual bone volume in the actual area was 2-5 mm preoperatively, after sinus lifting in mean 13 mm, after 1 year in mean 11.4 mm, and 2 years postoperatively in mean 10.6 mm. Local sinus lift with simultaneous bone augmentation and single-tooth replacement in the posterior maxilla is a predictable method although a certain bone volume reduction around the implant was evident at the 2-year follow-up. © 2009 Wiley Periodicals, Inc.

  5. Maxillary single-tooth replacement utilizing a novel ceramic restorative system: results to 30 months.

    Science.gov (United States)

    Ormianer, Zeev; Schiroli, Guido

    2006-01-01

    This study reports on the first longitudinal results of an alumina (70%)-zirconia (30%) ceramic restorative system for implant-supported, single-tooth replacement in the anterior maxillary jaw. Eighteen patients (9 men, 9 women, mean age = 42.4 years) were treated with 22 implants placed into 19 extraction sockets and 3 residual ridges. Eight implants were immediately loaded with nonoccluding provisional prostheses. All implants were definitively loaded with fully occluding ceramic restorations after osseointegration and soft tissue maturation. Patients were monitored from 7 to 30 months (mean = 18.1 months) after loading. All implants osseointegrated and were successfully restored. One case of abutment screw loosening occurred because of patient parafunction (bruxing), and another patient reported chewing pain attributed to malocclusion. Both problems were successfully resolved without further incidence. Within the context of this study, single-tooth replacement in the anterior maxillary jaw was successfully achieved with alumina-zirconia ceramic single-tooth restorations with up to 30 months of clinical function.

  6. Immediate loading of single-tooth implants in the posterior region.

    Science.gov (United States)

    Abboud, Marcus; Koeck, Bernd; Stark, Helmut; Wahl, Gerhard; Paillon, Roswitha

    2005-01-01

    The aim of this study was to evaluate the clinical response and safety of immediately loaded single-tooth implants placed in the posterior region of the maxilla and mandible. Single-tooth implants were placed in healed extraction sites in 20 adult patients. Temporary pre-fabricated acrylic resin crowns were prepared and adjusted. The crown occlusion was adjusted to obtain minimal contacts in maximum intercuspation. After 6 weeks a ceramometal or all-ceramic crown was cemented. Radiographic and clinical examinations were made at baseline and at 3, 6, and 12 months. Cortical bone response and peri-implant mucosal responses were evaluated. The marginal bone level at the time of implant placement was preserved. The mean change in marginal bone level was 0.01 mm at 12 months. The mean Periotest value after 360 days was -4. The peri-implant mucosal adaptation to the anatomic form of the provisional crown resulted in a natural esthetic outcome, and a gain in papilla length was observed. One implant failure was recorded because of provisional luting cement impaction. Clinical research has shown that immediate loading is a possible treatment modality. The immediate functional loading of implants placed in this study resulted in bone adaptation to loading. A satisfactory success rate with positive tissue responses was achieved. The results of this limited investigation indicated that immediate loading of unsplinted single-tooth implants in the posterior region may be a viable treatment option with an esthetic outcome.

  7. A 10-year prospective study of single tooth implants placed in the anterior maxilla.

    Science.gov (United States)

    Gotfredsen, Klaus

    2012-03-01

    The aim of the study was to evaluate the biological and technical outcomes of early and delayed placed single tooth implants after 10 years of follow-up. Twenty consecutive patients who needed a single tooth replacement in the anterior maxilla were included in this study. Ten implants were placed with an early placement protocol, that is, 4 weeks after tooth extraction, whereas the other 10 implants were placed with a conventional delayed placement protocol, for example, 12 weeks after tooth extraction. At the baseline and at the annual re-examinations, pain from implant regions, mobility, plaque, mucositis, and marginal bone levels were recorded. Biological and technical complications were registered. The patients evaluated the functional and aesthetic outcomes subjectively on a visual analogue scale after 3 and 10 years. All implants were still in situ after 10 years. The cumulative implant survival rate was 100%. Two implant-supported crowns were remade because of ceramic fractures. The 10-year crown survival rate was 90%. No significant differences in implant survival rates were found between the early and delayed protocols, regarding plaque retention, mucositis, or marginal bone levels. After 10 years, the mean marginal bone loss at both sides of the implants was less than 1.0 mm in the two groups. During the 10-year interval, 1 patient lost more than 1.5 mm of marginal bone, 3 patients lost between 1.0 mm and 1.4 mm of bone, and 16 patients lost less than 1.0 mm of bone as an average of the mesial and distal bone loss. This 10-year prospective clinical trial demonstrated a 100% implant survival and a 90% crown survival. The average marginal bone level change was less than 1 mm, and there was no difference between early and delayed implant placement. Patient satisfaction with the implant-supported single crowns reduced with time. © 2009 Wiley Periodicals, Inc.

  8. Implant-supported single-tooth restorations. A 12-year prospective study.

    Science.gov (United States)

    Donati, Mauro; Ekestubbe, Annika; Lindhe, Jan; Wennström, Jan L

    2016-10-01

    The aim of this study was to evaluate prospectively the 12-year outcome of implant-supported single-tooth restorations. Originally 45 self-tapping Astra Tech TiOblast ® ST-implants were installed by a two-stage protocol in 40 subjects requiring single-tooth prosthetic replacement for a missing tooth. Clinical and radiologic examinations were performed at completion of the prosthetic treatment 4-7 months after implant installation surgery and after 5 and 12 years in function. At 12 years 31 patients and 35 implants were available for evaluation. The overall failure rate after 12 years was 10.3% on the subject level and 9.1% on the implant level. The mean bone loss amounted to 0.67 mm (SD 2.20) on a subject level and 0.47 mm (1.72) on an implant level. Three subjects (10%) and three implants (8.6%) were diagnosed with peri-implantitis. Five subjects had experienced technical complications; three incidences of loosening of the abutment retention screw during the first 5 years and two minor porcelain fracture of the crown (two patients) between 5- and 12-years of follow-up. The findings reported in this 12-year prospective case series suggest that the use of the Astra Tech dental implants may be a valid treatment alternative for single-tooth replacement prostheses. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Active tactile sensibility of single-tooth implants versus natural dentition: a split-mouth double-blind randomized clinical trial.

    Science.gov (United States)

    Kazemi, Mahmoud; Geramipanah, Farideh; Negahdari, Ramin; Rakhshan, Vahid

    2014-12-01

    Unlike passive sensitivity of implants/teeth that is assessed more, only three controversial studies have compared active tactile sensibility (ATS) of implants and teeth. We aimed to explore the difference between the ATS of teeth and single-tooth implants. The ATS of single-tooth implants and contralateral teeth was measured in 25 patients after they bit on gold and placebo foils 0- to 70-μm thick, each for five times, in a random order blinded to patients and assessor, carried out at two sessions. Based on the experimental range of 0 μm (mock trials) to 70 μm, the sigmoid shape of psychometric curve was estimated to locate the 50% values as the ATS thresholds for each tooth or implant. ATS Data were analyzed using paired and unpaired t-tests and multiple linear regression (α = 0.05, β ≤ 0.1). Also, equivalence testing approach was used to assess semi-objectively the clinical significance. Average ATS values for teeth and implants were 21.4 ± 6.55 μm and 30.0 ± 7.55 μm, respectively (p = .0001 [paired t-test]). None of the geometric characteristics of implants nor duration of implant in function were correlated with the ATS (p > .4 [regression]). Age was positively associated with the ATS of both implants and teeth (p ≤ .019 [regression]). Tooth ATS (but not implant ATS) was significantly higher in males compared with females (p = .050 [unpaired t-test]), which contributed to a generalizable tooth-implant difference higher than 8-μm clinical equivalence margin in females. The ATS was not significantly different between arches or between anterior/posterior regions (p > .6). There was a slight but statistically significant difference between implant and tooth tactile sensitivities. © 2013 Wiley Periodicals, Inc.

  10. The alveolar process following single-tooth extraction: a study of maxillary incisor and premolar sites in man.

    Science.gov (United States)

    Misawa, Mônica; Lindhe, Jan; Araújo, Mauricio G

    2016-07-01

    The present investigation was performed to determine some dimensional alterations that occur in the alveolar process of the incisor and premolar sites of the maxilla following tooth removal. Computer-assisted cone-beam computed tomography (CBCT) scans were obtained from the maxilla using an iCAT unit, and involved edentulous and contralateral tooth sites. For each site included in the study, parasagittal and axial reconstructions, 1 mm apart, were made and measurements of different variables (cross-sectional area, height, and width) performed. The study involved 69 subjects and disclosed that the cross-sectional area and the height and width of the alveolar process of the lateral incisor site were the smallest and those of the second premolar the largest. All parameters had been significantly reduced after the completion of the ≥1 year of healing. Thus, the overall (i) cross-sectional area was reduced from 99.1 to 65.0 mm(2) , (ii) the height from 11.5 to 9.5 mm, and (iii) the width from 8.5 to 3.2 mm (marginal 1/3(rd) ), 8.9 to 4.8 mm (middle portion), and 9.0 to 5.7 mm (apical portion). The removal of single tooth caused marked hard tissue diminution. The loss of hard tissue was most pronounced in the buccal and marginal portions of the edentulous ridge that in most sites had acquired a triangular shape. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Single-tooth anesthesia: pressure-sensing technology provides innovative advancement in the field of dental local anesthesia.

    Science.gov (United States)

    Hochman, Mark N

    2007-04-01

    This article will review standard techniques for intraligamentary injection and describe the technology and technique behind a new single-tooth anesthesia system. This system and technique represents a technological advancement and a greater understanding of intraligamentary anesthesia.

  12. A multidisciplinary esthetic approach to single-tooth replacement and diastema closure.

    Science.gov (United States)

    Lyssova, Valentina; Estafan, Denise; Cunnigham, Ralph P

    2008-05-01

    Anterior tooth replacement has always posed an esthetic challenge for dentists. A multidisciplinary approach makes it possible to provide patients with esthetics and function. Treatment planning should involve other specialists when clinicians are faced with the additional esthetic concerns of the patient (such as anterior spatial anomalies and esthetically unpleasant existing restorations). Metal-ceramic fixed partial dentures have been used to allow the replacement of missing teeth for many years, providing both strength and esthetics. Several other options also are available, including implant placement. Dental implants in the esthetic zone are well-documented in the literature; numerous controlled clinical trials have shown overall implant survival and success rates. This article illustrates a step-by-step analysis and treatment option for a single-tooth replacement and maxillary anterior spatial dilemma using Captek crowns.

  13. Implant-supported single-tooth restorations: a 5-year prospective study.

    Science.gov (United States)

    Wennström, Jan L; Ekestubbe, Annika; Gröndahl, Kerstin; Karlsson, Stig; Lindhe, Jan

    2005-06-01

    Comparatively few studies are available reporting at least 5 years of follow-up data of implant-supported single-tooth replacements. To evaluate prospectively the 5-year outcome of implant-supported single-tooth prosthetic restorations. Forty subjects (mean age 41 years), 23 males and 17 females, who required single-tooth prosthetic replacement for a missing tooth were recruited. A total of 45 self-tapping implants (Astra Tech ST-implants)--40 in the maxilla and five in the mandible--were installed in a two-stage procedure. Abutment connection was performed 3-6 months after implant installation. Clinical and radiographic examinations were performed at the completion of the prosthetic treatment and once a year during a 5-year follow-up period. The analysis of peri-implant bone level alteration was performed on subject and implant levels and by the use of analysis of variance and binary logistic regression. Three patients were lost during the 5 years of follow-up. One implant was lost after 2.5 years in function and another four implants could not be accounted for at the 5-year follow-up examination. The overall failure rate at 5 years was 2.6% (subject level) and 2.3% (implant level). The mean loss of marginal bone at the implants during the first year in function was 0.06 mm (SD 0.67) on the subject level and 0.02 mm (0.65) on the implant level. During the subsequent 4 years the annual change in peri-implant bone level amounted to -0.02 mm (0.22) on both subject and implant levels. Thus, the mean total bone level change over the 5-year interval was -0.14 mm (1.04) on subject level and -0.11 mm (1.00) on the implant level of analysis (p>0.05). The frequency of implants with a 5-year bone loss of > or =1 mm was 13%. Approximately 50% of the implants demonstrated no bone loss. The present clinical trial on single-tooth replacements with the Astra Tech implant system demonstrated that the bone loss during the first year of function as well as annually thereafter was

  14. Outcome of bonded vs all-ceramic and metal- ceramic fixed prostheses for single tooth replacement.

    Science.gov (United States)

    Karl, Matthias

    2016-01-01

    The conventional treatment of a single missing tooth is most frequently based on the provision of a fixed dental prosthesis (FDPs). A variety of designs and restorative materials are available which have an impact on the treatment outcome. Consequently, it was the aim of this review to compare resin-bonded, all-ceramic and metal-ceramic FDPs based on existing evidence. An electronic literature search using "metal-ceramic" AND "fixed dental prosthesis" AND "clinical, all-ceramic" AND "fixed dental prosthesis" AND "clinical, resin-bonded" AND "fixed dental prosthesis" AND "clinical, fiber reinforced composite" AND "clinical, monolithic" AND "zirconia" AND "clinical" was conducted and supplemented by the manual searching of bibliographies from articles already included. A total of 258 relevant articles were identified. Metal-ceramic FDPs still show the highest survival rates of all tooth-supported restorations. Depending on the ceramic system used, all-ceramic restorations may reach comparable survival rates while the technical complications, i.e. chipping fractures of veneering materials in particular, are more frequent. Resin-bonded FDPs can be seen as long-term provisional restorations with the survival rate being higher in anterior locations and when a cantilever design is applied. Inlay-retained FDPs and the use of fiber-reinforced composites overall results in a compromised long-term prognosis. Recently advocated monolithic zirconia restorations bear the risk of low temperature degradation. Several variables affect treatment planning for a given patient situation, with survival and success rates of different restorative options representing only one factor. The broad variety of designs and materials available for conventional tooth-supported restorations should still be considered as a viable treatment option for single tooth replacement.

  15. Supplemental tooth in primary dentition

    OpenAIRE

    Mohan, Ravi Prakash Sasankoti; Verma, Sankalp; Singh, Udita; Agarwal, Neha

    2014-01-01

    An extra tooth causing numerical excess in dentition is described as supernumerary tooth, and the resultant condition is termed as hyperdontia. Hyperdontia is more commonly seen in the permanent dentition than primary one. Supernumerary tooth which resembles tooth shape and supplements for occlusion is called as supplemental tooth. We present a case with supplemental tooth in primary dentition.

  16. Supplemental tooth in primary dentition.

    Science.gov (United States)

    Mohan, Ravi Prakash Sasankoti; Verma, Sankalp; Singh, Udita; Agarwal, Neha

    2014-06-09

    An extra tooth causing numerical excess in dentition is described as supernumerary tooth, and the resultant condition is termed as hyperdontia. Hyperdontia is more commonly seen in the permanent dentition than primary one. Supernumerary tooth which resembles tooth shape and supplements for occlusion is called as supplemental tooth. We present a case with supplemental tooth in primary dentition. 2014 BMJ Publishing Group Ltd.

  17. Immediate single tooth replacement with subepithelial connective tissue graft using platform switching implants: a case series.

    Science.gov (United States)

    Chung, Seunghwan; Rungcharassaeng, Kitichai; Kan, Joseph Y K; Roe, Phillip; Lozada, Jaime L

    2011-10-01

    This case series evaluated the facial gingival stability following single immediate tooth replacement in conjunction with subepithelial connective tissue graft (SCTG). Implant success rate and peri-implant tissue response were also reported. Ten patients (6 male, 4 female), with a mean age of 52.1 (range = 22.7 to 67.1) years, underwent immediate implant placement and provisionalization with SCTG and were evaluated clinically and radiographically at presurgery (T0), at the time of immediate tooth replacement and SCTG (T1), and 3 months (T2), 6 months (T3), and 12 months (T4) after surgery. Data were analyzed using the Friedman and Wilcoxon signed-ranks tests at the significance level of α = .05. At 1 year, 9 of 10 implants remained osseointegrated with the overall mean marginal bone change of -0.31 mm and a mean facial gingival level change of -0.05 mm. The modified plaque index scores showed that patients were able to maintain a good level of hygiene throughout the study. The papilla index score indicated that at T4, more than 50% of the papilla fill was observed in 89% of all sites. When proper 3-dimensional implant position is achieved and bone graft is placed into the implant-socket gap, favorable success rate and peri-implant tissue response of platform switching implants can be achieved following immediate tooth replacement in conjunction with subepithelial connective tissue graft.

  18. Brace modification improves aerobic performance in Charcot-Marie-Tooth disease: a single-subject design.

    Science.gov (United States)

    Bean, J; Walsh, A; Frontera, W

    2001-08-01

    Ankle-foot orthoses (AFOs) can lower energy expenditure in patients with hemiplegia by 10%-13%. Review of the lower motor injury literature reveals insufficient physiologic evidence supporting the use or modification of AFOs in patients with lower motor neuron injury and, specifically, progressive conditions such as Charcot-Marie-Tooth disease. We sought to test the hypothesis that optimal AFOs would improve submaximal aerobic performance and submaximal perceived exertion, while producing no change in maximal aerobic capacity. In an individual with Charcot-Marie-Tooth disease, a single-subject design study was used. An A-B-A design was used, with "A" corresponding to use of the patient's old AFOs and "B" corresponding to the newly prescribed AFOs. The subject underwent treadmill exercise tolerance testing using a modified Balke protocol. Indirect calorimetry was used to measure oxygen consumption per unit time (VO2), and the Borg scale was used to measure perceived exertion. At the same submaximal exercise intensities, VO2, rate-pressure product, and perceived exertion were all reduced when using the modified AFOs. Additionally, these conditions allowed the subject to conduct the treadmill exercise test 20% longer. Maximal VO2 remained constant under all conditions. Optimizing the AFO prescription in a patient with Charcot-Marie-Tooth disease can enhance physiologic performance and perceived exertion at submaximal activity levels. Larger controlled trials are necessary to further demonstrate such benefits in patients with progressive neuropathy and other causes of lower motor neuron injury.

  19. Immediate functional loading of implants in single tooth replacement: a prospective clinical multicenter study.

    Science.gov (United States)

    Donati, Mauro; La Scala, Vincenzo; Billi, Mauro; Di Dino, Biagio; Torrisi, Paolo; Berglundh, Tord

    2008-08-01

    The aim of the present study was to evaluate the outcome of immediate functional loading of implants in single-tooth replacement using two different installation procedures. One hundred and fifty-one subjects, who required single-tooth rehabilitation in the area of 15-25 and 35-45, were enrolled in eight private clinics in Italy. The implant sites were randomly allocated to one of the following treatment groups. In the control group, in which a standard preparation procedure for implant placement and submerged healing of the implant was used, abutment connection and loading of the implants were performed 3 months after installation. In the test group 1, a standard preparation procedure for the implant placement and immediate functional loading of implant was carried out. In the test 2 group, however, a modified implant installation procedure (osteotome technique) was used followed by immediate functional loading of the implant. Clinical and radiographic examinations were performed at 3 and 12 months of follow-up at all sites. Three implants (5.5%) from the test 2 group (osteotome preparation) and one (2%) from the test 1 group (conventional drill preparation) failed to integrate and were removed one and three months after implant installation. The mean marginal bone loss assessed at 12 months was 0.31 mm (test 1), 0.25 mm (test 2) and 0.38 mm (control) (no statistically significant differences were found between the three treatment groups.) It is suggested that immediate functional loading of implants that are placed with a conventional installation technique and with sufficient primary stability may be considered as a valid treatment alternative in a single-tooth replacement.

  20. A retrospective analysis of episodes of single tooth extraction under general anaesthesia for adults.

    Science.gov (United States)

    Hong, B; Birnie, A

    2016-01-15

    To investigate the provision of adult dental extraction under general anaesthesia (DGA) at the Royal Cornwall Hospitals NHS Trust (RCHT)-- specifically adult single tooth DGA episodes in regards to numbers, demographics, justifications, and appropriateness regarding the use of resources. Data were collected retrospectively from the patient case notes and electronic records for the complete study cohort. This study included all episodes of adult single tooth DGA in all RCHT sites during 2014, except for mandibular third molar and impacted teeth. Each case was tested against the DGA case selection criteria empirically devised for this study. In 2014, 106 episodes of adult single tooth DGA were carried out in RCHT that met the inclusion criteria. Younger females from more socio-economically deprived areas of Cornwall were increasingly likely to have this procedure. Mental disorders were the most prevalent co-morbidity (21.7%) in this cohort. The vast majority of patients (93.4%) had previously tolerated dental treatment without the need for general anaesthesia (GA). Many referrals (46.2%) and listings (30.2%) specifically stated patient demand-driven reasons. None of the cohort had DGA due to failure of sedation. There were potentially 11 episodes that met the DGA case selection criteria. Patients waited for 126 days (median) from the referral date for an operation which took seven minutes (median) to complete. The majority (83%) of the cases were simple exodontia. Twenty patients (18.9%) had previous DGA. Potentially a considerable proportion of GA prescription appeared to be driven by patient demand rather than clinical need. This study poses a fundamental question--what drives the demand for DGA? National data collection and specific DGA case selection criteria are recommended.

  1. Marginal bone preservation in single-tooth replacement: a 5-year prospective clinical multicenter study.

    Science.gov (United States)

    Donati, Mauro; La Scala, Vincenzo; Di Raimondo, Rosario; Speroni, Stefano; Testi, Massimo; Berglundh, Tord

    2015-06-01

    Few long-term studies are available comparing immediate and conventional loading protocols of implant-supported single-tooth replacement. The aim of the present randomized controlled clinical trial was to evaluate prospectively the 5-year clinical and radiological outcome of immediate functional loading implants used in single-tooth replacement. One hundred fifty-one subjects, who required single-tooth rehabilitation in the area from position 15 to 25 and from 35 to 45, were enrolled in eight private clinics in Italy. A randomization protocol was applied to allocate the implants in three treatment groups: one control group and two test groups. In the control group, implant placement was performed according to a conventional drilling procedure, and the implants were submerged for 3 months before abutment connection and loading. Implants allocated in the test group 1 and 2 followed an immediate functional loading protocol. While in test group 1, implant placement was performed according to conventional drilling procedure, in test group 2, a modified implant installation procedure (osteotome technique) was applied. Clinical and radiographic examinations were performed during the 5-year follow-up, and technical and biological complications were registered. Although four implants (three in the test group 2 and one in the test group 1) were lost in the immediate functional loading groups in the first year of follow-up, no further implant loss occurred in any of the treatment groups in the following monitoring period up to 5 years. No significant differences on marginal bone level changes were observed between the treatment groups. About 52% of all implants showed bone gain in the period from 1-year to 5-year follow-up. The percentage of all implants that in the same interval of time showed bone loss was about 28%. Although few technical complications were recorded in the period of time up to 5 years, implants showing biological complication were 5.7%. It is suggested

  2. A fixed partial appliance approach towards treatment of anterior single tooth crossbite: Report of two cases

    Directory of Open Access Journals (Sweden)

    M Gawthaman

    2017-01-01

    Full Text Available Crossbite can be treated using both removable and fixed appliances. This paper describes the report of two cases by a method of treating anterior single tooth in crossbite which is locked out of arch form with a simple fixed partial appliance. Orthodontic treatment was initiated by creating space for the locked out incisor using open coil spring and further corrected using MBT brackets and nitinol archwire for alignment. Treatment goals were achieved, and esthetics and occlusion were maintained postoperatively. Treatment objectives were obtained within a short duration using this technique, and there was an improvement in patients' smile.

  3. Evaluating the Association of Tooth Form of Maxillary Central Incisors with Face Shape Using AutoCAD Software: A Descriptive Study.

    Science.gov (United States)

    Mehndiratta, Aditi; Bembalagi, Mahantesh; Patil, Raghunath

    2017-12-27

    To assess the different forms of maxillary central incisors (MCI) and determine their association with the shape of the face for men and women. A total of 200 subjects (100 women, 100 men) aged between 18 and 30 years with healthy dentition were randomly selected from K.L.E. V.K Institute of Dental Sciences, Belagavi, India. Two standardized photographs (portrait and shape of the MCI) were taken for each subject and opened in AutoCAD 2009 software that was used to prepare technical drawings of face and tooth forms. The dental ratios (extent of line TA: extent of line TB) obtained after the tracings, were classified as tapered (≤0.61), ovoid (>0.61 and <0.69), or square (≥0.70). This classification was used to relate tooth form to the shape of the face and compare the form of MCI between men and women. Association between the shape of the MCI and the face was determined by Chi-square test using R 3.3.1 software. The most prevalent tooth form among the subjects was ovoid (women, 32%; men, 31%) followed by tapered (women, 13%; men, 16%). The least prevalent shape was square (women, 5%; men, 3%). The most prevalent face shape was tapered (women, 34%; men, 25%) followed by ovoid (women, 15%; men, 22%) and the least prevalent was square (women, 1%; men, 3%). An association between face shape and tooth form was statistically not significant. The most prevalent tooth form in both men and women was ovoid, and the least prevalent was square. The association between face shape and tooth form was not significant and did not abide by William's "Law of Harmony." However, there was an association between face shape and gender. © 2017 by the American College of Prosthodontists.

  4. A 3-year prospective study of implant-supported, single-tooth restorations of all-ceramic and metal-ceramic materials in patients with tooth agenesis

    DEFF Research Database (Denmark)

    Hosseini, Mandana; Worsaae, Nils; Schiødt, Morten

    2013-01-01

    OBJECTIVES: The purpose of this clinical study was to describe outcome variables of all-ceramic and metal-ceramic implant-supported, single-tooth restorations. MATERIALS AND METHODS: A total of 59 patients (mean age: 27.9 years) with tooth agenesis and treated with 98 implant-supported single...... abutment materials. The frequency of biological complications was higher at restorations with all-ceramic restorations than metal-ceramic crowns. Loss of retention, which was only observed at metal-ceramic crowns, was the most frequent technical complication, and the marginal adaptations of all-ceramic...... restoration materials were registered. After 3 years, the patient-reported outcome variables at different restoration materials were not significantly different. CONCLUSION: The biological outcomes at the zirconia and metal abutments were comparable. All-ceramic crowns demonstrated better colour match...

  5. Single tooth anesthesia versus conventional anesthesia: a cross-over study.

    Science.gov (United States)

    Campanella, Vincenzo; Libonati, Antonio; Nardi, Roberto; Angotti, Vincenzo; Gallusi, Gianni; Montemurro, Edoardo; D'Amario, Maurizio; Marzo, Giuseppe

    2018-03-10

    The aim of the present study was to compare an electronic device, the Wand Injection System (Milestone Scientific Livingstone), with conventional anesthesia in terms of the following: pain sensation during anesthetic injection; effectiveness in achieving adequate anesthesia for a complete painless dental treatment; post-operative discomfort; and patient's anxiety toward dental treatment. Eighty adults from 18 to 70 years were enrolled in this cross-over study. Each patient served as his/her own control being subject to two anesthesia techniques: conventional and Single Tooth Anesthesia (STA) performed with the Wand. A split-mouth design was adopted in which each tooth undergoing conservative restorative or endodontic treatment received anesthesia with both techniques at 1-week interval. Before anesthetic administration, the patients' anxiety levels were determined. Physiological parameteres were measured before, during, and after the two injection procedures, and the Visual Analogue Scale (VAS) was used to assess pain of injection, discomfort, and anesthetic efficacy. Differences in assessment of pain's injection, discomfort, anesthetic efficacy, vital parameters (heart rate, blood pressure, and oxygen saturation), and state anxiety levels were analyzed using Student's t test (p value < 0.001). The mean injection pain and post-operative discomfort ratings with Wand were lower than those with conventional syringe (p = 0.022 and p < 0.001, respectively). No differences were found in the assessment of anesthetic efficacy. Blood pressure and heart rate mean values were lower during the anesthesia performed with the Wand than with the conventional syringe (p < 0.001). The anxiety level was higher during the first appointment, independently from the device used for the injections. The STA technique resulted in lower pain, discomfort, and lower intensity of physiological parameters. Single Tooth Anesthesia could be an efficacious alternative to

  6. Single Visit Apexification Procedure of a Traumatically Injured Tooth with a Novel Bioinductive Material (Biodentine)

    Science.gov (United States)

    Jingarwar, Mahesh Madhukar; Pathak, Anuradha

    2015-01-01

    ABSTRACT Aim of this article is to present a case wherein single visit apexification of a traumatically injured tooth was done with a bioactive material–Biodentine. An injury sustained between the ages of 6 and 14 can adversely affect pulpal health and interrupt root development. In these instances, apexification is generally the preferred treatment. A 10 years old male patient presented with coronal fracture of the left upper central incisor. Clinical and radiographic assessment showed negative pulpal sensibility and arrested apical root development. Artificial apical barrier induction with Biodentine followed by endodontic treatment and prosthetic rehabilitation was decided as the line of treatment. To conclude, this bioactive and biocompatible calcium-based cement can regenerate damaged dental tissues and represents a promising alternative to the conventional multivisit apexification technique. Clinical significance: Biodentine which is a biologically active cement can be an efficient alternative to the conventional apexification materials which were hitherto recommended. How to cite this article: Bajwa NK, Jingarwar MM, Pathak A. Single Visit Apexification Procedure of a Traumatically Injured Tooth with a Novel Bioinductive Material (Biodentine). Int J Clin Pediatr Dent 2015;8(1):58-61. PMID:26124583

  7. Anterior single-tooth dental implant restorations: now is the perfect time to recall significant contributions.

    Science.gov (United States)

    Sullivan, Daniel Y

    2003-01-01

    Significant contributions by clinicians, researchers, and manufacturers have brought us to a previously almost unimaginable point in time, where it is possible to place and restore a single dental implant in the esthetic zone with a success rate above 96% and with the probability that it will look very much like a natural tooth. In addition, in select cases it is possible to do the extraction, implant placement, and provisional restoration on the same day. There is very little trauma at the implant site, which results in greater comfort for the patient and ultimately greater tissue preservation long-term. We have now observed single-tooth anterior implant cases for 15 years and have every belief that these implants will continue to function in health for many years. So what is next? We will have to wait and see, but it is this clinician's hope that the next 15 years will bring us more of these cooperative efforts that have so dramatically improved our patients' lives.

  8. Stress distribution difference between Lava Ultimate full crowns and IPS e.max CAD full crowns on a natural tooth and on tooth-shaped implant abutments.

    Science.gov (United States)

    Krejci, Ivo; Daher, René

    2017-04-01

    The goal of this short communication is to present finite element analysis comparison of the stress distribution between CAD/CAM full crowns made of Lava Ultimate and of IPS e.max CAD, adhesively luted to natural teeth and to implant abutments with the shape of natural teeth. Six 3D models were prepared using a 3D content-creating software, based on a micro-CT scan of a human mandibular molar. The geometry of the full crown and of the abutment was the same for all models representing Lava Ultimate full crowns (L) and IPS e.max CAD full crowns (E) on three different abutments: prepared natural tooth (n), titanium abutment (t) and zirconia abutment (z). A static load of 400 N was applied on the vestibular and lingual cusps, and fixtures were applied to the base of the models. After running the static linear analysis, the post-processing data we analyzed. The stress values at the interface between the crown and the abutment of the Lt and Lz groups were significantly higher than the stress values at the same interface of all the other models. The high stress concentration in the adhesive at the interface between the crown and the abutment of the Lava Ultimate group on implants might be one of the factors contributing to the reported debondings of crowns.

  9. Evidence-based decision making: replacement of the single missing tooth.

    Science.gov (United States)

    Fugazzotto, Paul A

    2009-01-01

    Single-tooth replacement may be effected through various methods, including the use of a resin-bonded fixed partial denture, a conventional fixed partial denture, and a single implant-supported crown. Although the introduction of newer therapeutic modalities, surgical and restorative techniques, and restorative materials has significantly expanded available treatment options, a greater demand is now placed on the diagnostic and treatment planning acumen of the clinician. The questions confronting each clinician are when to apply each treatment modality and how to use these therapeutic approaches to their maximum benefit for the patient. This article focuses on the factors that should be considered when making such clinical decisions and offers a framework within which to formulate appropriate treatment algorithms.

  10. Tactile sensibility of single-tooth implants and natural teeth under local anesthesia of the natural antagonistic teeth.

    Science.gov (United States)

    Enkling, Norbert; Heussner, Stefan; Nicolay, Claudia; Bayer, Stefan; Mericske-Stern, Regina; Utz, Karl-Heinz

    2012-04-01

    The term osseoperception describes the capability of developing a subtle tactile sensibility over dental implants. The present clinical study aims at clarifying the question of how far tactile sensibility is to be attributed to the periodontium of the natural opposing tooth of the implant. Thirty-two subjects with single-tooth implants with natural opposing teeth were included in this clinical, single-blind, split-mouth study. The natural antagonistic tooth of the implant and the corresponding natural contralateral tooth were anesthetized with a locally infiltrated articaine anesthetic. In a computer-assisted and randomized way, copper foils of varying thickness (0-100 µm) were placed interocclusally between the single-tooth implant and the natural opposing tooth, and between the contralateral pair of natural opposing teeth in order to investigate the active tactile sensibility according to the psychophysical method of constant stimuli and evaluate it statistically by the Weibull distribution. The average tactile sensibility of the implants with anesthetized antagonists at the 50% value calculated by means of the Weibull distribution was 20 ± 11 µm with a support area (90%-10% value) of 77 ± 89 µm. For the pair of natural teeth, the tactile sensibility at the 50% value was 16 ± 9 µm with a support area of 48.4 ± 93 µm. This resulted in an average intraindividual difference of 3.5 ± 7 µm at the 50% value and 29 ± 93 µm in the support area. The statistical calculations demonstrated an equivalent tactile sensibility (50% value) of the single-tooth implant and the contralateral natural control tooth with the natural antagonists being anesthetized in each case (double t-test, equivalence limit ± 8 µm, P 80%). Apparently, the active tactile sensibility of single-tooth implants with natural opposing teeth is not only to be attributed to the periodontium of the opposing tooth but also to a perception over the implant itself. This could support the hypothesis

  11. A 5-year prospective study of single-tooth replacements supported by the Astra Tech implant: a pilot study

    DEFF Research Database (Denmark)

    Gotfredsen, Klaus

    2004-01-01

    BACKGROUND: Implant-supported single-tooth replacements are an increasingly used method to replace teeth, especially in young patients. Therefore, long-term validation of different treatment modalities with different implant systems is of great importance. PURPOSE: The aim of the present study...... was to make a biologic, technical, and aesthetic evaluation of single-tooth replacement supported by the Astra Tech implant (Astra Tech AB, Mölndal, Sweden) during a 5-year period. MATERIALS AND METHODS: Twenty patients were divided into two consecutively treated groups. In group A the implants were placed...... "early" in the extraction sockets, and standard single-tooth abutments were used. In group B the implants were placed "delayed," and preparable abutments were used. Clinical examinations including registration of plaque, bleeding, crown lengths, soft tissue marginal level, papilla height, complications...

  12. MODELING OF RUNNING CUTTERS FOR SHAPING OF IMPROVED NONINVOLUTE TOOTH GEARS

    Directory of Open Access Journals (Sweden)

    Tatyana TRETYAK

    2012-05-01

    Full Text Available The questions of tooling design for production of advanced gears are considered. Engineering is based on the special applied development of the mathematical theory of multiparametric mappings of space. In fulfilled engineering of gear cutting tools for shaping of noninvolute gears it is provided for exclusion of distorted profiling after tool regrinds. There are proposed calculation algorithms, which may be used in dataware of respective CAD/CAM systems of maintenance for tooling backup. Among developed tools there are assembled shaping cutters with prismatic and round cutters. Compensatory possibilities of proposed assembled shaping cutters are ensured by repositioning of shaped cutting edges after their regrindings: by linear displacement of prismatic shaped cutters and angular displacement of round ones respectively.

  13. [Tooth shape and color as criteria for or against orthodontic space closure in case of a missing lateral incisor].

    Science.gov (United States)

    Wriedt, Susanne; Werner, Patrick; Wehrbein, Heinrich

    2007-01-01

    The aim of this study was to examine the esthetic parameters that are applied, more or less unconsciously, in deciding for or against orthodontic space closure in the case of aplasia or traumatic loss of lateral incisors. The width-height index for teeth 13 to 23 was measured on 200 dental students. The VITA Easyshade system was used to determine the components of the tooth color (L, C, h) and to identify differences between each tooth. Eight investigators subjectively assessed digital photographs of the subjects, opting for or against space closure. The Spearman correlation coefficients were calculated for the parameters measured. A comparison of the parameters showed that not one factor alone was responsible for the decision for or against space closure for esthetic reasons. Orthodontists were more likely to favor space closure when the canine was slightly wider and had a less pointed shape and the differences were very small between canine and central incisor in terms of hue, chroma, and lightness. We observed that the subjective decision on the esthetic aspects of space closure correlates closely with the objective criteria.

  14. Single anterior tooth replacement by a cast lingual loop connector - a conservative approach.

    Science.gov (United States)

    Dandekeri, Shilpa Sudesh; Dandekeri, Savita

    2014-09-01

    One of the most challenging and complex treatment modality is replacement of single anterior tooth. This can be overcome by different treatment options such as implant-supported restorations as well as conventional porcelain-fused-to-metal and resin-bonded fixed partial dentures. Drifting of teeth into the edentulous area may reduce the available pontic space; whereas a diastema existing before an extraction may result in excessive mesiodistal dimension to the pontic space. Loop connector fixed partial denture (FPD) may be the simplest and best solution to maintain the diastema and provide optimum restoration of aesthetics. This article describes the procedure for the fabrication of a loop connector FPD to restore an excessively wide anterior edentulous space in a patient with existing spacing between the maxillary anterior teeth.

  15. Immediate, non-submerged, root-analogue zirconia implant in single tooth replacement.

    Science.gov (United States)

    Pirker, W; Kocher, A

    2008-03-01

    This report demonstrates the successful clinical use of a modified root-analogue zirconia implant for immediate single tooth replacement. A right maxillary premolar was removed and a custom-made, root-analogue, roughened zirconia implant with macro-retentions in the interdental space was fabricated and placed into the extraction socket 4 days later. Four months after root implantation a composite crown was cemented. No complications occurred during the healing period. An excellent esthetic and functional result was achieved with the composite crown. No clinically noticeable bone resorption or soft-tissue recession was observed at 26 months follow up. Significant modifications such as macro-retentions seem to indicate that primary stability and excellent osseointegration of immediate root-analogue zirconia implants can be achieved, while preventing unesthetic bone resorption. The macro-retentions must be limited to the interdental space to avoid fracture of the thin buccal cortex. This successful case warrants further clinical research in well controlled trials.

  16. Single tooth replacement utilizing implants in the esthetic zone: a case report.

    Science.gov (United States)

    Egbert, Nicholas; Ahuja, Swati; Brandt, Robert; Jain, Vinay; Wicks, Russell

    2013-07-01

    Replacing a single tooth with an implant has become a common dental procedure; however, careful evaluation is necessary before placing one in the esthetic zone. Thorough diagnosis and planning - including the use of transposed diagnostic casts and cone beam computed tomography scans - can help dentists predict the final esthetic result prior to treatment, and help inform the patient of the potential result prior to performing any irreversible therapy. In the present case, the primary concern was the presurgical location of the facial free gingival margin (FGM) of the implant-supported crown, in relation to the adjacent teeth. Steps taken to correct the position of the facial FGM prior to implant placement led to a successful esthetic result.

  17. Comparing pink and white esthetic scores to layperson perception in the single-tooth implant patient.

    Science.gov (United States)

    Jones, Adam R; Martin, William

    2014-01-01

    The pink esthetic score (PES) and white esthetic score (WES) are tools utilized to objectively evaluate single-tooth implant restorations (STIR) in the esthetic zone.1 A questionnaire study was developed to address two objectives: (1) establish a total PES/WES score that is clinically acceptable based on layperson perception and (2) report outcomes in laypeople's perceptions of pink and white deficiencies. A presentation book of 27 color-calibrated photographs of a STIR in the esthetic zone (canine to canine) surrounded by virgin teeth and one photograph without a STIR (control) was presented to three prosthodontists (evaluators) to conduct a PES/WES evaluation. The same 27 photographs were presented to 101 laypeople. The laypeople were instructed to identify which tooth was the STIR. The laypeople were also instructed to record, based on pink or white esthetics, what factors influenced their decision on the selection of the STIR. For the evaluator's scores of the 27 cases, the mean PES score was 5.7 (range, 3 to 10). The mean WES score was 6.2 (range, 3 to 10). The mean total PES/WES score was 11.9 (range, 6 to 20). The mean percentage of laypeople unable to correctly identify the STIR was 59.1% (range, 13.9% to 89.2%). When the evaluator's PES/WES score was greater than 12, 79% of the layperson population was not able to identify a STIR (ρ = -0.86). In addition, when the PES score was 6, 90% of the laypeople were not able to perceive a pink deficiency (ρ = -0.65), and when the WES score was 6, 83% of the laypeople were not able to perceive a white deficiency (ρ = -0.57). Within the limitations of this study, in single-tooth implant restorations, a total PES/WES score greater than 12 would provide a STIR that would be clinically acceptable in the majority of situations. This study also concluded that laypeople identify white esthetic deficiencies more easily than pink esthetic deficiencies.

  18. Immediate loading of post-extractive single-tooth implants: a 1-year prospective study.

    Science.gov (United States)

    Cristalli, Maria Paola; Marini, Roberta; La Monaca, Gerardo; Sepe, Claudio; Tonoli, Federica; Annibali, Susanna

    2015-09-01

    The aim of this prospective clinical trial was to assess clinical, radiological, and esthetic outcomes of immediate-loaded post-extractive implants after 1 year of follow-up. Twenty-four consecutive patients (15 females and nine males) with a mean age of 47.27 years (range 35-65) requiring single-tooth extraction in the maxillary or mandibular anterior or premolar areas were enrolled. Twenty-five NobelActive implants (Nobel Biocare, Göteborg, Sweden) were placed and loaded immediately after tooth extraction. The definitive prosthetic restoration was delivered 6 months later. Clinical parameters, marginal bone loss, as well as, pink and white esthetic scores (PES and WES) were evaluated at 3, 6, and 12 months after implant placement. After 12-month follow-up period, a success rate of 91.67% was reported: Two of the 25 initially placed implants were lost after 4 weeks due to lack of osseointegration. The mean marginal bone loss after 1-year follow-up was 0.383 (SD ± 0.749) at mesial site and 0.278 (SD ± 0.595) at distal site. No statistically significant changes in the full-mouth plaque score (FMPS) and in the full-mouth bleeding score (FMBS) were observed from baseline to 12 months. The mean total PES/WES was 17.13 ± 1.91 (range: 13-20). None of 23 implants had an overall score immediate placement and loading of a single NobelActive(™) implant in a fresh extraction socket may be considered a valuable and predictable option in terms of implant success as well as hard and soft tissues stability. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Immediate Loading of Anterior Single Tooth Implants Placed in Healed Sites : Five-Year Results of a Randomized Clinical Trial

    NARCIS (Netherlands)

    den Hartog, Laurens; Raghoebar, Gerry M.; Stellingsma, Kees; Vissink, Arjan; Meijer, Henny J. A.

    2016-01-01

    Purpose: The aim of this study was to compare the 5-year outcome of immediate loading with that of conventional loading for anterior single-tooth implants placed in healed sites. It was hypothesized that immediate loading is not inferior to conventional loading. Materials and Methods: A total of 62

  20. Supernumerary Molars and Wisdom Tooth Shape Alterations in Patients with Neurofibromatosis Type 1

    Directory of Open Access Journals (Sweden)

    Reinhard E. Friedrich

    2017-12-01

    Full Text Available Objectives: The purpose of the present study was the systematic investigation of numerical and morphological aberrations of teeth in the wisdom teeth region in neurofibromatosis type 1 patients. Material and Methods: The panoramic radiographs of 179 patients were analysed for supernumerary molars and dysplastic wisdom teeth with special reference to facial tumour type. The results were compared to radiographic findings obtained in panoramic radiographs of age- and sex-matched controls. Results: The total number of dysplastic or supernumerary molars was 21 (17 individuals, 4.75% and predominantly a finding of the maxilla (maxilla: 15, mandible: 1, maxilla and mandible: 1. Differences of dental findings between neurofibromatosis type 1 (NF1 patients (n = 15 and the control group (n = 2 were statistically significant (P < 0.01. All individuals with supernumerary molars were diagnosed as being affected with NF1. This difference achieved statistical significance when it was considered that the event may occur at least once per quadrant, and thus the individual potentially needs to be considered four times (P = 0.0038. Conclusions: This investigation revealed that supernumerary molars and aberrations in wisdom tooth form are more common in patients than in age- and sex-matched controls. There is no association between these findings and a specific feature of the disease, id est facial manifestation of a trigeminal nerve sheath tumour (plexiform neurofibroma. The cause of this phenomenon is unknown. A review of these dental findings on other neurofibromatosis type 1 study groups should be attempted.

  1. Allometry, merism, and tooth shape of the lower second deciduous molar and first permanent molar.

    Science.gov (United States)

    Bailey, Shara E; Benazzi, Stefano; Buti, Laura; Hublin, J-J

    2016-01-01

    This study investigates the effect of allometry on the shape of lower dm2 (dm2) and lower M1 (M1) crown outlines and examines whether the trajectory and magnitude of allometric scaling are shared between Neandertals and Homo sapiens. Our sample included 164 specimens: 57 recent H. sapiens, 44 Upper Paleolithic H. sapiens, 17 early H. sapiens, and 46 Neandertals. Of these, 59 represent dm2/M1 pairs from the same individuals. Occlusal photographs were used to obtain crown shapes of dm2s and M1s. Principal components analysis (PCA) of the matrix of shape coordinates was used to explore the pattern of morphological variation across the dm2 and M1 samples. Allometry was investigated by means of the Pearson product-moment correlation coefficient. Two-block partial least squares (2B-PLS) analysis was used to explore patterns of covariation between dm2 and M1 crown outlines of matched individual pairs. The PCA confirmed significant differences between Neandertal and H. sapiens dm2 and M1 shapes. Allometry accounted for a small but statistically significant proportion of the total morphological variance. The magnitude of the allometric contribution to crown shape was stronger among Neandertals than among H. sapiens. However, we could not reject the null hypothesis that the two species share the same allometric trajectory. The 2B-PLS analysis of the pooled sample of paired individuals revealed a significant correlation in crown shape between dm2 and M1. While Procrustes distances differed significantly between dm2 and M1 in Neandertals, it did not among H. sapiens groups. Our results confirm several of the results obtained by a similar study of upper dm2/M1 (dm(2)/M(1)), but there are differences as well. Neandertal dm2/M1 shapes are less derived than those of the dm(2)/M(1). Such differences may support previous studies, which have suggested that different developmental and/or epigenetic factors affect the upper and lower dentitions. © 2015 Wiley Periodicals, Inc.

  2. A macroscopic model for magnetic shape-memory single crystals

    Czech Academy of Sciences Publication Activity Database

    Bessoud, A. L.; Kružík, Martin; Stefanelli, U.

    2013-01-01

    Roč. 64, č. 2 (2013), s. 343-359 ISSN 0044-2275 R&D Projects: GA AV ČR IAA100750802; GA ČR GAP201/10/0357 Institutional support: RVO:67985556 Keywords : magneto striction * evolution Subject RIV: BA - General Mathematics Impact factor: 1.214, year: 2013 http://library.utia.cas.cz/separaty/2012/MTR/kruzik-a macroscopic model for magnetic shape-memory single crystals.pdf

  3. Prosthetic restoration in the single-tooth gap: patient preferences and analysis of the WTP index.

    Science.gov (United States)

    Augusti, Davide; Augusti, Gabriele; Re, Dino

    2014-11-01

    The objective of this study was to evaluate the preference of a patients' population, according to the index of willingness to pay (WTP), against two treatments to restore a single-tooth gap: the implant-supported crown (ISC) and the 3-unit fixed partial denture prosthesis (FPDP) on natural teeth. Willingness to pay values were recorded on 107 subjects by asking the WTP from a starting bid of €2000 modifiable through monetary increases or decreases (€100). Data were collected through an individually delivered questionnaire. The characteristics of the population and choices made, the median values and WTP associations with socio-demographic parameters (Mann-Whitney and Kruskal-Wallis tests), correlations between variables (chi-square test in contingency tables) and significant parameters for predicting WTP values obtained in a multiple linear regression model were revealed. The 64% of patients expressed a preference for ISC, while the remaining 36% of the population chose the FPDP. The current therapeutic choice and those carried out in the past were generally in agreement (>70% of cases, P = 0.0001); a relationship was discovered between the anterior and posterior area to the same method of rehabilitation (101 of 107 cases, 94.4%). The WTP median values for ISC were of €3000 and of €2500 in the anterior and posterior areas, respectively. The smallest amount of money has been allocated for FPDP in posterior region (median of €1500). The "importance of oral care" for the patient was a significant predictor, in the regression model analysis, for the estimation of both anterior (P = 0.0003) and posterior (P replacement of a single missing tooth, showing a higher WTP index in the anterior area. Among investigated socio-demographic variables, the importance assigned by the patient to oral care appeared to influence WTP values of the rehabilitation, regardless the location of the single gap in the mouth. © 2013 John Wiley & Sons A/S. Published by John

  4. Clinical evaluation and prosthetic complications of single tooth replacements by non-submerged implants.

    Science.gov (United States)

    Mericske-Stern, R; Grütter, L; Rösch, R; Mericske, E

    2001-08-01

    The aim of the present study was to evaluate single tooth replacements by non-submerged implants. In the time period from 1990 to 1998, 72 patients were consecutively admitted for treatment with a total of 109 solid screw ITI-implants supporting single crowns. All crowns were ceramic to metal fused with a ceramic occlusal surface and mounted to the octa-abutment. The mean observation time was 4.3 years, ranging from >1 to 9 years. The implants were monitored regularly by periimplant parameters. Periapical radiographs using the parallel technique were taken after the healing period and in 1999 for comparative measurements. No implant was lost during the healing phase, while 3 failures occurred after a loaded period of 2.5 and >5 years, respectively. The 5-year cumulative survival rate was 99.1%. In the course of the study, only 2 implants exhibited marginal inflammation that required treatment. The radiographically measured distance (DIB) from the implant shoulder to the first implant-bone contact was significantly increased in 1999 and different between the two readings. However, this difference in DIB was not significant between implants with a short (1 year) and long (>5 years) observation period. It was concluded that changes in the crestal bone level occur mostly in the first postsurgical year. Prosthetic complications were rare, mostly encountered in the first year after loading and often limited to re-tightening of the occlusal screw.

  5. Patient satisfaction and esthetic outcome after immediate placement and provisionalization of single-tooth implants involving a definitive individual abutment.

    Science.gov (United States)

    Hartlev, Jens; Kohberg, Peter; Ahlmann, Søren; Andersen, Niels T; Schou, Søren; Isidor, Flemming

    2014-11-01

    To assess patient satisfaction and esthetic outcome after immediate placement and provisionalization of single-tooth implants involving a definitive individual abutment and a provisional crown followed by later placement of a definitive crown. In private practice, a single-tooth implant was placed immediately after tooth extraction in the esthetic zone of 54 patients. A definitive individual abutment and a provisional crown were mounted in the same visit. The definitive crown was placed after a mean period of 7 months. After a mean follow-up period of 33 months, the subjective and professional evaluation of the total implant treatment, peri-implant soft tissues, and implant crown were assessed on a 10-cm visual analog scale (VAS). The professional esthetic treatment outcome was also evaluated using pink esthetic score (PES), white esthetic score (WES), and total score of PES/WES. The evaluation of total implant treatment, peri-implant soft tissues, and implant crown demonstrated a significantly higher subjective than professional score for all 3 parameters (P provisionalization of single-tooth implants involving a definitive individual abutment and provisional crown followed by later placement of a definitive crown demonstrated high subjective and professional satisfaction. Generally, the professionals seem to be more critical than the patients. A strong correlation was observed between the professional VAS scores and the PES and WES scoring systems. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Long-term cumulative survival and mechanical complications of single-tooth Ankylos Implants: focus on the abutment neck fractures

    OpenAIRE

    Shim, Hye Won; Yang, Byoung-Eun

    2015-01-01

    PURPOSE To evaluate the cumulative survival rate (CSR) and mechanical complications of single-tooth Ankylos? implants. MATERIALS AND METHODS This was a retrospective clinical study that analyzed 450 single Ankylos? implants installed in 275 patients between December 2005 and December 2012. The main outcomes were survival results CSR and implant failure) and mechanical complications (screw loosening, fracture, and cumulative fracture rate [CFR]). The main outcomes were analyzed according to ag...

  7. Replacement of missing posterior tooth with off-center placed single implant: Long-term follow-up outcomes.

    Science.gov (United States)

    Anitua, Eduardo; Murias-Freijo, Alia; Flores, Javier; Alkhraisat, Mohammad Hamdan

    2015-07-01

    The distal offset placement of a single implant to replace a single tooth would overcome the shortcomings of the placement of a single wide implant in the posterior region. However, long-term evaluation is still-lacking. The purpose of this study was to evaluate the long-term outcomes of patients treated with a single tooth restoration supported by a distal-offset placed implant. Thirty-one patients with a single restoration supported by an off-center placed implant were evaluated. The patients' demographic data were described. The known implant length was used as a reference to calibrate the linear measurements on digital periapical radiographs. Implant details, survival, and prosthetic complications were analyzed. The implant survival rate was analyzed with the Kaplan-Meier method. Thirty-four implants were placed with a distal offset to support single-tooth restorations. Twenty patients were women, and patient age was 56 ± 12 years. The implants had a follow-up time from loading up to 10 years (average: 4 ± 3 years). Most of the implants were inserted in type II bone, and 85% were placed in the molar region. The distal offset placement of the implant and the selection of a wide-diameter implant resulted in a mesial bone loss of 0.85 ± 0.57 mm and distal bone loss of 0.83 ± 0.68 mm. One implant failed after 4 months from insertion, resulting in a cumulative survival rate of 97.1%. No prosthetic complications were registered. The distal offset placement of an implant is an efficient option for restoring a single missing posterior tooth when mesiodistal space is limited. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  8. Two-year prospective clinical comparison of immediate replacement vs. immediate restoration of single tooth in the esthetic zone.

    Science.gov (United States)

    Palattella, Piermario; Torsello, Ferruccio; Cordaro, Luca

    2008-11-01

    To compare the immediate restoration of single implants in the esthetic zones performed on implants placed immediately after tooth extraction or 8 weeks later (immediate replacement vs. immediate restoration). Sixteen patients (10 women and 6 men) with a mean age of 35 years (ranging from 21 to 49 years old) were treated from 2004 to 2005 for single-tooth replacement in the upper arch. The patients were randomly divided into two groups: in the test group patients received implants placed and restored (non-occlusal loading) at the time of tooth extraction; in the control group implants were placed 8 weeks after tooth extraction and immediately restored. All the patients received tapered effect (TE) implants from the Straumann Dental Implant System. The following parameters were evaluated at the moment of provisional restoration (within 48 h after implant placement) and at the 2 years follow-up visit: marginal bone resorption, papilla index, position of the mucosal margin. The implant stability quotient was measured at the moment of implant placement and at the moment of the delivery of the definitive restoration. No statistically significant differences were found in any of the studied parameters between the test and the control groups (P>0.05). The implant stability quotient values between the test and control groups were significant (P0.05). The results of the present study suggest that immediate replacement without functional loading may be considered a valuable therapeutic option for selected cases of single-tooth replacement in the esthetic area when TE implants are used. Implant stability at the moment of implant placement is slightly inferior in the immediate replacement group, but it does not affect the treatment result.

  9. Posterior implant single-tooth replacement and status of adjacent teeth during a 10-year period: a retrospective report.

    Science.gov (United States)

    Misch, Carl E; Misch-Dietsh, Francine; Silc, Jennifer; Barboza, Eliane; Cianciola, Louis J; Kazor, Christopher

    2008-12-01

    The purpose of this case series study was to evaluate posterior single-tooth implant survival and the long-term conditions of the adjacent teeth. A retrospective evaluation of 1,162 consecutive patients with a single missing posterior tooth treated with 1,377 external hex implants supporting 1,365 restorations surrounded by natural teeth over a 1- to 10-year period was reviewed from four private offices. Implant survival data were collected relative to stage I to stage II healing, stage II to prosthesis delivery, and prosthesis delivery to up to 10 years of follow-up. Long-term adjacent tooth conditions were assessed, including decay, endodontic therapy (root canal therapy [RCT]), and/or extraction during the follow-up period. Of the 1,377 implants inserted, there were 11 surgical failures from stage I to stage II healing. There was one failure from stage II healing to prosthesis delivery. There were two prosthetic-phase failures. The surgical success rate was 99.2%, whereas the overall survival rate was 98.9% at an average of 61 months of follow-up (range, 12 to 125 months). A total of 2,589 adjacent teeth were followed during the study. No natural adjacent tooth was lost during this period. Interproximal decay developed in 129 adjacent teeth (5%), and nine adjacent teeth required RCT (0.4%) as a result of decay or restoration. The use of single-tooth implants as replacements for posterior missing teeth is a viable long-term treatment. Adjacent natural teeth complications are minimal for as long as 10 years after implant insertion.

  10. Considerations for single tooth replacement in an esthetic zone-review of conservative treatment options.

    Science.gov (United States)

    Singh, Raghuwar Dayal; Singh, Saumyendra V; Chand, Pooran; Ramashanker

    2011-01-01

    This literature review aimed to identify and assess the conservative treatment options for replacing a single missing anterior tooth, for patients who cannot afford implants or traditional bridges. The evidence was obtained using MEDLINE searches. A total of 19 studies met the inclusion criteria. None of these studies scored higher than 10 of 17, suggesting that all studies did not have strong evidence. Three of the studies examined resin-bonded bridges (RBBs), whereas the other three investigated removable partial dentures (RPDs). None of the studies had random patient selection. Three of these studies had controlled allocation of patients. The other three allowed new patients to enter the study throughout the study period. Placement of the prosthesis was only conducted in one study, whereas the rest of the studies examined patients with preexisting prostheses. In general, all 19 studies were weak due to poor study design, no acceptable controls, no direct comparison between RBBs and RPDs, lack of longitudinal studies and no differentiation between the anterior and posterior prostheses. Therefore, no definitive treatment conclusion can be made until studies of stronger design are conducted.

  11. CAD/CAM glass ceramics for single-tooth implant crowns: a finite element analysis.

    Science.gov (United States)

    Akça, Kvanç; Cavusoglu, Yeliz; Sagirkaya, Elcin; Aybar, Buket; Cehreli, Murat Cavit

    2013-12-01

    To evaluate the load distribution of CAD/CAM mono-ceramic crowns supported with single-tooth implants in functional area. A 3-dimensional numerical model of a soft tissue-level implant was constructed with cement-retained abutment to support glass ceramic machinable crown. Implant-abutment complex and the retained crown were embedded in a Ø 1.5 × 1.5 cm geometric matrix for evaluation of mechanical behavior of mono-ceramic CAD/CAM aluminosilicate and leucite glass crown materials. Laterally positioned axial load of 300 N was applied on the crowns. Resulting principal stresses in the mono-ceramic crowns were evaluated in relation to different glass ceramic materials. The highest compressive stresses were observed at the cervical region of the buccal aspect of the crowns and were 89.98 and 89.99 MPa, for aluminosilicate and leucite glass ceramics, respectively. The highest tensile stresses were observed at the collar of the lingual part of the crowns and were 24.54 and 25.39 MPa, respectively. Stresses induced upon 300 N static loading of CAD/CAM aluminosalicate and leucite glass ceramics are below the compressive strength of the materials. Impact loads may actuate the progress to end failure of mono-ceramic crowns supported by metallic implant abutments.

  12. Single-Tooth Implant Versus Three-Unit Fixed Partial Denture: A Study of Oral Health-Related Quality of Life.

    Science.gov (United States)

    Park, Sun-Young; Oh, Sung-Hee; Kim, Jimin; Jung, Yea Ji; Park, Joo-Yeon; Lee, Eui-Kyung; Kim, Seong-Kyun; Kim, Younhee

    2016-01-01

    Many studies have investigated the impact of prosthetic treatment on oral health-related quality of life (OHRQoL). However, most of these have been performed among fully or partially edentulous patients. Studies involving patients with a single missing tooth are limited. The purpose of this study was to compare the OHRQoL between patients treated by single-tooth implants and three-unit fixed partial dentures (FPDs) for single missing tooth restoration. A cross-sectional survey was conducted in Korea with patients drawn by stratified purposive sampling based on age. OHRQoL was measured using the Korean version of the 14-item Oral Health Impact Profile (OHIP-14K) questionnaire. Pre- and posttreatment OHIP-14K scores were compared by paired t test. Single-tooth implants and three-unit FPDs were compared by two-sample t test. In addition, multiple regression analysis was used to evaluate the impact of treatment mode on OHIP-14K total score after adjusting the effect of demographics and clinical factors. Thirty-five patients with single-tooth implants and 36 patients with three-unit FPDs were included. All participants had a significant improvement in OHRQoL compared with before the treatment (P single-tooth implants and three-unit FPDs for single missing tooth replacement resulted in significant and similar improvement of OHRQoL.

  13. Assessment of parental tooth-brushing following instruction with single-headed and triple-headed toothbrushes.

    Science.gov (United States)

    Telishevesky, Yoel S; Levin, Liran; Ashkenazi, Malka

    2012-01-01

    The purpose of this study was to evaluate the effect of toothbrush design on the ability of parents to effectively brush their children's teeth. Parents of children (mean age=5.1±0.75 years old) from 4 kindergarten schools were randomly assigned to receive instruction in brushing their children's teeth using a manual single-headed toothbrush (2 schools) or a triple-headed toothbrush (2 schools). The parents' ability to brush their children's teeth was evaluated according to a novel toothbrush performing skill index (Ashkenazi Index), based on 2 criteria: (1) placement of the toothbrush on each tooth segment to be brushed ("reach"); and (2) completion of enough strokes on each segment ("stay"). One month after instruction, tooth-brushing ability was re-evaluated and plaque index of the children's teeth was assessed. One month after instruction, parents using the triple-headed toothbrush received significantly higher scores on the tooth-brushing performance index (~86%), than did those in the single-headed group (~61%; P=.001). The plaque index was significantly higher in the single-headed group (0.97±0.38) vs the triple-headed group (0.72±0.29; Pbrushing performance index correlated negatively with the plaque index (Pbrushing by parents than does a single-headed toothbrush.

  14. Evaluation of four instruments with different working motion using artificial plastic model with C-shaped single canal.

    Science.gov (United States)

    Sekiya, Miki; Maeda, Munehiro; Katsuumi, Ichiroh; Igarashi, Masaru

    2018-02-10

    The purpose of this study was to evaluate four instruments with different working motion for preparation of a C-shaped single canal wall using the same artificial plastic models reproduced from a human tooth. One tooth with root canal morphology C1 (the shape is an uninterrupted "C" with no separation or division) was selected among three-dimensional micro-computed tomography (micro-CT) imaging data of extracted human teeth. Imaging data were then converted into STL form data, and twenty-four C-shaped root canal model blocks were manufactured using this STL form data. These blocks were randomly divided into four groups of six blocks each and instrumented as follows: stainless steel K-files (SSK), Self-Adjusting File (SAF), ProTaper NEXT (PTN) and RECIPROC (REC). Micro-CT images taken before and after canal preparation were superimposed, and instrumented canal area, percentage of instrumented canal area, part of instrumented canal area, volume of instrumented canal and time taken for instrumentation were evaluated for each group. The greatest instrumented canal area, percentage of instrumented canal area and volume of instrumented canal were as follows (in decreasing order): SSK > SAF > PTN > REC (P instrumentation was as follows (in decreasing order): SAF > SSK > PTN > REC (P instrumented all root canal walls equally. PTN and REC required less time taken for instrumentation, but showed unequal instrumentation.

  15. A 3-year prospective study of implant-supported, single-tooth restorations of all-ceramic and metal-ceramic materials in patients with tooth agenesis.

    Science.gov (United States)

    Hosseini, Mandana; Worsaae, Nils; Schiødt, Morten; Gotfredsen, Klaus

    2013-10-01

    The purpose of this clinical study was to describe outcome variables of all-ceramic and metal-ceramic implant-supported, single-tooth restorations. A total of 59 patients (mean age: 27.9 years) with tooth agenesis and treated with 98 implant-supported single-tooth restorations were included in this study. Two patients did not attend baseline examination, but all patients were followed for 3 years. The implants supported 52 zirconia, 21 titanium and 25 gold alloy abutments, which retained 64 all-ceramic and 34 metal-ceramic crowns. At baseline and 3-year follow-up examinations, the biological outcome variables such as survival rate of implants, marginal bone level, modified Plaque Index (mPlI), modified Sulcus Bleeding Index (mBI) and biological complications were registered. The technical outcome variables included abutment and crown survival rate, marginal adaptation of crowns, cement excess and technical complications. The aesthetic outcome was assessed by using the Copenhagen Index Score, and the patient-reported outcomes were recorded using the OHIP-49 questionnaire. The statistical analyses were mainly performed by using mixed model of ANOVA for quantitative data and PROC NLMIXED for ordinal categorical data. The 3-year survival rate was 100% for implants and 97% for abutments and crowns. Significantly more marginal bone loss was registered at gold-alloy compared to zirconia abutments (P = 0.040). The mPlI and mBI were not significantly different at three abutment materials. The frequency of biological complications was higher at restorations with all-ceramic restorations than metal-ceramic crowns. Loss of retention, which was only observed at metal-ceramic crowns, was the most frequent technical complication, and the marginal adaptations of all-ceramic crowns were significantly less optimal than metal-ceramic crowns (P = 0.020). The professional-reported aesthetic outcome demonstrated significantly superior colour match of all-ceramic over metal

  16. Practice-based clinical evaluation of zirconia abutments for anterior single-tooth restorations.

    Science.gov (United States)

    Rinke, Sven; Lattke, Anja; Eickholz, Peter; Kramer, Katharina; Ziebolz, Dirk

    2015-01-01

    This study aimed to determine the survival rate and prevalence of biologic and technical complications associated with single-tooth implants with all-ceramic abutments in the anterior region. A total of 33 patients were restored with 50 anterior implants and temporarily luted all-ceramic crowns on prefabricated zirconia abutments. All of the patients subsequently received annual supportive maintenance; 27 patients (18 women, 22-74 years) with 42 implants participated in the final maintenance visit and were included in the study (follow-up 78.1 ± 27.0 months). The time-dependent survival rate (Kaplan-Meier) and the frequency of prosthetic complications (abutment fracture [AF], screw loosening [SL], fracture of veneering ceramics [VF], retention loss [RL]) and biologic complications (peri-implantitis) were calculated to determine the success rates. No implant loss (implant-related survival rate 100%) but one abutment fracture occurred throughout the entire observation period; therefore, the survival rate of the superstructures (in situ criterion) was 97.6% (95% confidence interval [CI] 0.930- 1.000) after 7 years. Eleven restorations were affected by prosthetic complications: RL (n = 4), VF (n = 5), and SL (n = 2). Peri-implantitis was diagnosed for two implants (probing depth > 5 mm, bleeding on probing [BOP]/suppuration, and bone loss > 3 mm) (implant-related peri-implantitis rate 4.8%). No restoration required replacement due to complications. The success rate (event-free restoration) was 75.9% (95% CI 0.636- 0.882) after 7 years. Considering the calculated survival rate, the application of all-ceramic zirconia implant abutments in the anterior region can be recommended as a reliable therapy in private practice. Fractures of veneering ceramics were the most common prosthetic complication.

  17. Immediate placement and provisionalization of single-tooth implants involving a definitive individual abutment: a clinical and radiographic retrospective study.

    Science.gov (United States)

    Hartlev, Jens; Kohberg, Peter; Ahlmann, Søren; Gotfredsen, Erik; Andersen, Niels Trolle; Isidor, Flemming; Schou, Søren

    2013-06-01

    To assess with a mean follow-up period of 33 months (median: 31 month, range: 11-89 month) the treatment outcome after immediate placement and provisionalization of single-tooth oral implants involving a definitive individual abutment and a provisional crown followed by later placement of a definitive crown. 68 patients with 68 single-tooth implants in the esthetic zone were consecutively treated; 55 of these patients were included in the study. The treatment involved tooth extraction, implant placement, placement of a definitive individual abutment, and a provisional crown in the same visit in private practice. The definitive crown was placed after a mean period of 7 months. The primary outcome measures included implant survival, definitive implant crown survival, and overall treatment survival. The secondary outcome measures included probing depth, bleeding on probing, peri-implant marginal bone level, marginal bone level of the neighboring tooth surfaces, biological complications, and technical complications. Of the inserted implants 98% survived and of the definitive crowns mounted a survival of 100% was observed. Consequently, the overall treatment survival was 98%. The mean probing depth was 2.9 mm at implant level and 63% of the implants were characterized by no bleeding on probing. The mean peri-implant marginal bone level was 2 mm. A significant mean peri-implant marginal bone level gain of 0.5 mm was observed from implant placement to the follow-up (95% CI: 0.07-0.89 mm, P = 0.022). No significant changes of the marginal bone level at the neighboring tooth surfaces were seen. Four episodes of peri-implant inflammation were identified in three patients, while 46 incidents of loosening of the provisional crown occurred in 33 patients. One abutment screw loosened before placement of the definitive crown. Finally, loosening of four definitive crowns occurred in four patients. Immediate placement and provisionalization of single-tooth oral implants

  18. Functional and esthetic considerations for single-tooth Ankylos implant-crowns: 8 years of clinical performance.

    Science.gov (United States)

    Döring, Katrin; Eisenmann, Eduard; Stiller, Michael

    2004-01-01

    Following the loss of an anterior natural tooth, the mucogingival complex begins to collapse. The early placement of endosseous dental implants can prevent or reduce the extent of this collapse. If there is a long interval between the loss of the natural tooth and the placement of the implant prosthetic replacement, this collapse tends to increase significantly. This paper will report on the clinical success of this implant product in the fabrication of esthetic, functional, and harmonious replacements for missing single, natural teeth for a period of 8 years. A total of 275 single Ankylos implant tooth restorations in the anterior and posterior jaw regions were placed and monitored for 8 years. Of these, 264 implants were restored using the titanium Balance abutments, and only 11 were restored using ceramic abutments. The final restorations were either metal-ceramic or full-ceramic crowns and were cemented with glass ionomer cement. The survival rate was 98.2%, with only 5 implants being lost during the healing phase. There were no other implant losses in the postloading period that averaged 3.2 years. To date, there have been no mechanical complications associated with the prosthetic components (ie, screw loosening, screw breaking, or crown breaking) for either the titanium or the ceramic abutments. Experience with the Ankylos system with single-tooth replacement indications may be considered positive with regard to the esthetic and functional results of the treatment. The lack of mechanical complications and problems with the hard and soft tissue in the loading phase of the implants suggests the functional safety of the tapered connection between implant and abutment.

  19. Optimizing anterior esthetics of a single-tooth implant through socket augmentation and immediate provisionalization: A case report with 7-year follow-up

    Directory of Open Access Journals (Sweden)

    Po-Sung Fu

    2012-10-01

    Full Text Available Tooth extraction inevitably accompanies alveolar ridge resorption with loss of pre-existing tissue morphology. Replacing missing teeth with dental implants has become popular, but restoring anterior teeth with implant-supported restorations is a technique-sensitive task and poses challenges for dentists. With the progress of implant dentistry, the demand for optimal esthetics has become linked with the desire for faster, easier techniques that shorten treatment time and also satisfy patients. Immediate provisionalization of a single-tooth implant provides significant benefits compared with traditional delayed protocols, such as aiding the contouring of peri-implant soft tissue and enhancing patient comfort and satisfaction. This article describes a meticulous approach to a hopeless maxillary central incisor with root fracture. The defect in the extraction socket was reconstructed using autogenous bone harvested from the chin. Four months later, an implant was installed and immediately restored. After another healing period of 6 months, the peri-implant soft tissue had been shaped and matured according to the contours of the provisional restoration. The emergence profile was used to duplicate the definitive restoration. Peri-implant esthetics was achieved through socket augmentation and immediate provisionalization of the implant. This treatment modality attained predictable and maintainable outcomes, both functionally and esthetically.

  20. Clinical Outcomes After Immediate and Late Implant Loading for a Single Missing Tooth in the Anterior Maxilla.

    Science.gov (United States)

    Yildiz, Pnar; Zortuk, Mustafa; Kiliç, Erdem; Dinçel, Mehmet; Albayrak, Haydar

    2016-08-01

    This study compared the clinical outcomes of 1-year follow-up of immediate and late implant loading after implant restoration of a single tooth in the anterior maxilla. Thirty-three patients with missing teeth in the anterior maxilla were included in this study (18 immediate loading and 15 late loading). Standard periapical radiographs were obtained to evaluate the vertical bone loss around the implant. For both implant groups, periimplant parameters (probing depth, gingival bleeding index, gingival index (GI), modified plaque index, width of keratinized gingiva) were evaluated. There were no significant differences in bone loss, the widths of keratinized gingiva, the GI, and modified plaque index between the immediate implant loading and late implant loading groups (P > 0.05). A significant difference in the probing depth was observed between these groups at the initial and 1-month evaluations (P replacement of a missing tooth in anterior maxilla.

  1. Experimental zirconia abutments for implant-supported single-tooth restorations in esthetically demanding regions: 4-year results of a prospective clinical study.

    Science.gov (United States)

    Glauser, Roland; Sailer, Irena; Wohlwend, Arnold; Studer, Stephan; Schibli, Monica; Schärer, Peter

    2004-01-01

    This prospective clinical study evaluated an experimental implant abutment made of densely sintered zirconia with respect to peri-implant hard and soft tissue reaction as well as fracture resistance over time. Twenty-seven consecutively treated patients with 54 single-tooth implants were included. Zirconia abutment ingots were individually shaped and set on the implants with gold screws. All-ceramic (Empress I) crowns were cemented using a composite cement. At the 1- and 4-year examinations, reconstructions were evaluated for technical problems (fracture of abutment or crown, loosening of abutment screw). Modified Plaque and simplified Gingival Indices were recorded at implants and neighboring teeth, and peri-implant bone levels were radiographically determined. All but 1 of the 27 patients with 53 restorations could be evaluated at 1 year, and 36 restorations in 18 patients were evaluated 4 years after abutment and crown insertion. The median observation period for the reconstructions was 49.2 months. No abutment fractures occurred. Abutment screw loosening was reported for 2 restorations at 8 months and 27 months, respectively. Mean Plaque Index was 0.4 (SD 0.6) at abutments and 0.5 (SD 0.6) at teeth; mean Gingival Index was 0.7 (SD 0.5) at abutments and 0.9 (SD 0.5) at teeth. Mean marginal bone loss measured 1.2 mm (SD 0.5) after 4 years of functional loading. Zirconia abutments offered sufficient stability to support implant-supported single-tooth reconstructions in anterior and premolar regions. The soft and hard tissue reaction toward zirconia was favorable.

  2. Single Tooth Replacement Using InCeram Resin Bonded Fixed Partial Denture: A Clinical Report.

    Science.gov (United States)

    Moslehifard, Elnaz; Farid, Farzaneh

    2014-01-01

    This clinical report describes a treatment option for replacement of a missing mandibular anterior tooth using InCeram resin bonded fixed partial denture (RBFPD). The conventional approach for replacing mandibular incisors dictates the placement of either a conventional porcelain-fused-to-metal (PFM) bridge, Maryland bridge, or fiber-reinforced composite veneer bridge and several appearance-related disadvantages have been reported in the use of a prosthesis that incorporates a metal substructure. The InCeram bridge is a minimally invasive restoration and eliminates undesirable incisal graying frequently observed in metal RBFPDs. This method was successfully clinically applied to overcome shortcomings of other approaches that may require a minimal invasive technique to preserve lasting sound tooth structure.

  3. Single Tooth Replacement Using InCeram Resin Bonded Fixed Partial Denture: A Clinical Report.

    Directory of Open Access Journals (Sweden)

    Elnaz Moslehifard

    2014-02-01

    Full Text Available This clinical report describes a treatment option for replacement of a missing mandibular anterior tooth using InCeram resin bonded fixed partial denture (RBFPD. The conventional approach for replacing mandibular incisors dictates the placement of either a conventional porcelain-fused-to-metal (PFM bridge, Maryland bridge, or fiber-reinforced composite veneer bridge and several appearance-related disadvantages have been reported in the use of a prosthesis that incorporates a metal substructure. The InCeram bridge is a minimally invasive restoration and eliminates undesirable incisal graying frequently observed in metal RBFPDs. This method was successfully clinically applied to overcome shortcomings of other approaches that may require a minimal invasive technique to preserve lasting sound tooth structure.

  4. Advanced single tooth torquing plier with high precision: A clinical innovation

    Directory of Open Access Journals (Sweden)

    Jitendra Raghuwanshi

    2017-01-01

    Full Text Available Torque is the force which gives the operator control over the movements of roots of teeth in bilateral direction. There are various pliers available to apply torque in individual tooth, but none of the pliers are capable of measuring accurately the degrees of torque incorporated, so we have attempted to make a modified torquing plier to incorporate and measure the degrees of incorporated torque precisely.

  5. Single Tooth Replacement Using InCeram Resin Bonded Fixed Partial Denture: A Clinical Report.

    OpenAIRE

    Elnaz Moslehifard; Farzaneh Farid

    2014-01-01

    This clinical report describes a treatment option for replacement of a missing mandibular anterior tooth using InCeram resin bonded fixed partial denture (RBFPD). The conventional approach for replacing mandibular incisors dictates the placement of either a conventional porcelain-fused-to-metal (PFM) bridge, Maryland bridge, or fiber-reinforced composite veneer bridge and several appearance-related disadvantages have been reported in the use of a prosthesis that incorporates a metal substruct...

  6. Dimensions of hard and soft tissue around adjacent, compared with single-tooth, zirconia implants.

    Science.gov (United States)

    Kniha, K; Modabber, A; Kniha, H; Möhlhenrich, S C; Hölzle, F; Milz, S

    2018-01-01

    Preservation or regeneration of the papilla has always been a challenge around consecutive implants or with implants next to teeth, and many studies have evaluated the papilla's behaviour and patterns based on surgical technique and prosthetic design, though evidence about its behaviour around zirconia implants is scarce. The aim of this study was to evaluate papilla behaviour between implants and teeth (tooth-implant group) and between consecutive implants (implant-implant group). Ninety patients with 122 zirconia implants (Straumann ® PURE Ceramic Implant) were examined at the one-year follow up. We measured the effect of the distance: first from the base of the contact point of the crowns to the contact with bone at the implant site (D1); secondly, to the contact with the bone at the neighbouring tooth or implant site (D2); and thirdly on the papillary deficit (D3). In both the tooth-implant group and the implant-implant group, D1 and D2 correlated significantly with the papillary deficit (D3), whereas D2 was the major determinant factor (Spearman's rho=0.60). In both groups, when D1 and D2 were implant group than in the implant-implant group (p=0.048). We conclude that the ideal distance from the base of the contact point to the bone contact at the implant and to the bone contact at the adjacent tooth in both groups is implants has a significant impact on that of the papilla. Copyright © 2017 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  7. Evaluation of single-tooth replacement by an immediate implant covered with connective tissue graft as a biologic barrier.

    Science.gov (United States)

    Jyothi, S G; Triveni, M G; Mehta, D S; Nandakumar, K

    2013-05-01

    The aim of the present study was to evaluate the survival rate of Screw-Vent(®) immediate implants augmented with sub epithelial connective tissue graft for single-tooth replacement for 1 year. Ten patients (five men and five women), with the mean age of 25.3 years, were consecutively treated on the out-patient basis by the placement of Screw-Vent(®) dental implants in to the fresh extraction sockets in association of augmentation with sub epithelial connective tissue graft harvested from the palate, supporting single crowns. The clinical and radiographic parameters were recorded to evaluate the peri-implant soft tissue health and marginal bone loss, respectively, for each patient at baseline and at every 3 months interval for 1 year. The 1 year cumulative survival rate of Screw-Vent(®) dental implants was 100% for all 10 patients. Statistical analysis demonstrated highly significant values indicating an improvement in peri-implant soft tissue parameters in terms of peri-implant aesthetic parameters, which estimated the keratinized mucosa width. Statistically, non-significant marginal bone loss or gain indicated stable condition in hard tissue parameters. Single-tooth replacement by Screw-Vent(®) dental implants in to a fresh extraction socket, in association with guided bone regeneration using autologous connective tissue graft is a predictable treatment as demonstrated by the 100% implant survival rates and appreciable increase in the width of the keratinized mucosa at 1 year follow up.

  8. Facial gingival tissue stability after connective tissue graft with single immediate tooth replacement in the esthetic zone: consecutive case report.

    Science.gov (United States)

    Kan, Joseph Y K; Rungcharassaeng, Kitichai; Morimoto, Taichiro; Lozada, Jaime

    2009-11-01

    The present consecutive case report evaluated facial gingival tissue stability after immediate tooth replacement with connective tissue grafting in the esthetic zone. The implant success rate and peri-implant tissue response were also recorded. A total of 20 consecutive patients with a mean age of 52.3 years (range 28 to 71), who had undergone 20 single immediate tooth replacement with connective tissue grafting, were evaluated clinically and radiographically at the preoperative examination, immediately after implant placement and provisionalization with connective tissue grafting, and at the latest follow-up appointment. The data were analyzed using the t test and Wilcoxon signed rank test at a significance level of alpha = .05. At the preoperative examination, a thick gingival biotype was observed in 8 patients and a thin gingival biotype in 12. At a mean follow-up of 2.15 years (range 1 to 4), all implants were functioning and exhibited a thick biotype. At the latest follow-up appointment, no significant differences (P > .05) were found between the initially thick and thin gingival biotypes in the mean mesial marginal bone level changes (-0.53 versus -0.55 mm), the mean distal marginal bone level changes (-0.50 versus -0.44 mm), and the mean facial gingival level changes (+0.23 mm versus +0.06 mm). The frequency distribution of the papilla index score showed that peri-implant papillae were well preserved at the latest follow-up visit. With proper 3-dimensional implant positioning and bone grafting into the implant-socket gap, the facial gingival level can be maintained after connective tissue grafting with single immediate tooth replacement, regardless of the initial gingival biotype, indicating that the thin gingival biotype can be converted to the thick gingival biotype morphologically and behaviorally with this procedure. Nevertheless, careful patient selection and treatment planning, as well as immaculate execution by skillful clinicians, are required to

  9. Tissue Dimensional Changes in Single-Tooth Immediate Extraction Implant Placement in the Esthetic Zone: A Retrospective Clinical Study.

    Science.gov (United States)

    Amato, Francesco; Polara, Giorgio; Spedicato, Giorgio Alfredo

    The aim of this study was to evaluate the buccopalatal volumetric tissue change that occurs following flapless single-tooth immediate extraction placement in the esthetic area and to analyze the role of four different variables. Patients in need of a single-tooth replacement in the anterior maxillary or mandibular area (premolar to premolar) were recruited for the study. Patients were treated using four different therapeutic modalities: group 1 (healing abutment), group 2 (healing abutment + bone graft), group 3 (provisional restoration), and group 4 (provisional + bone graft). Alginate impressions were taken the day of implant insertion before tooth extraction (T0), at 1 month (T1), at 3 months (T2), and at 6 months (T3). Buccopalatal dimension (BPD) was measured on the study casts at 1, 3, and 5 mm apical to the free gingival margin and compared between T0 and T1 and T2 and T3. Seventy-seven patients were included in the study, 29 men and 48 women with a mean age of 54 years (range: 24 to 76 years), and 80 implants were inserted. Thirteen implants were inserted in group 1, 13 in group 2, 20 in group 3, and 34 in group 4. The BPD contraction was more evident for group 1, smaller in group 2 and group 3, and minimal in group 4. Repeated measures analysis of variance (ANOVA) and post hoc tests were used. The data analyzed were considered statistically significant with a level of α = .05. The interaction effect P value was numerically zero. The results of this study seem to indicate that volumetric tissue changes after immediate extraction placement in the esthetic area can be minimized if a provisional is immediately connected and a bone graft is inserted simultaneously.

  10. Limb, tooth, beak: Three modes of development and evolutionary ...

    Indian Academy of Sciences (India)

    Here we compare the embryological processes that shape the vertebrate limb bud, the mammalian tooth and the avian beak. The implied notion of development in the standard evolutionary picture is met only in the case of the vertebrate limb, a single-primordium organ with morphostatic shaping, in which cells rearrange in ...

  11. Cost-effectiveness of endodontic molar retreatment compared with fixed partial dentures and single-tooth implant alternatives.

    Science.gov (United States)

    Kim, Sahng G; Solomon, Charles

    2011-03-01

    One of the most challenging situations in dentistry is a failed root canal treatment case. Should a failed root canal-treated tooth be retreated nonsurgically or surgically, or should the tooth be extracted and replaced with an implant-supported restoration or fixed partial denture? These four treatment alternatives were compared from the perspective of cost-effectiveness on the basis of the current best available evidence. The costs of the four major treatment modalities were calculated using the national fee averages from the 2009 American Dental Association survey of dental fees. The outcome data of all treatment modalities were retrieved from meta-analyses after electronic and manual searches were undertaken in the database from MEDLINE, Cochrane, ISI Web of Knowledge, and Scopus up to April 2010. The treatment strategy model was built and run with TreeAge decision analysis software (TreeAge Software, Inc, Williamstown, MA). Endodontic microsurgery was the most cost-effective approach followed by nonsurgical retreatment and crown, then extraction and fixed partial denture, and finally extraction and single implant-supported restoration. The cost-effectiveness analysis showed that endodontic microsurgery was the most cost-effective among all the treatment modalities for a failed endodontically treated first molar. A single implant-supported restoration, despite its high survival rate, was shown to be the least cost-effective treatment option based on current fees. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  12. The Impact of Buccal Bone Defects and Immediate Placement on the Esthetic Outcome of Maxillary Anterior Single-Tooth Implants.

    Science.gov (United States)

    Kamperos, Georgios; Zambara, Ioanna; Petsinis, Vassileios; Zambaras, Dimitrios

    2016-08-01

    This study aimed to evaluate the impact of buccal bone defects and immediate placement on the esthetic outcome of maxillary anterior single-tooth implants. The archives of the Department of Dental Implants & Tissue Regeneration at Hygeia Hospital during a 5-year period (2010-2014) were retrospectively analyzed, in search of patients treated with a single-tooth implant after extraction of a maxillary incisor. The status of the buccal bone plate and the time of implant placement were recorded. The pink esthetic score (PES) of each case was evaluated, with a maximum score of 14. In total, 91 patients were included in the study. The mean PES was 10.5. The outcome was considered satisfactory (PES ≥ 8) in 89% and (almost) perfect (PES ≥ 12) in 35% of the cases. Immediate implant placement had no impact on PES (P > .05), even though it demonstrated slightly greater variability. On the other hand, buccal bone defects had a negative effect on PES (P implants in the anterior maxilla. The presence of buccal bone defects is considered a negative prognostic factor, whereas immediate implant placement does not affect the esthetic outcome.

  13. Fatigue resistance of 2 different CAD/CAM glass-ceramic materials used for single-tooth implant crowns.

    Science.gov (United States)

    Çavuşoğlu, Yeliz; Sahin, Erdal; Gürbüz, Riza; Akça, Kivanç

    2011-10-01

    To evaluate the fatigue resistance of 2 different CAD/CAM in-office monoceramic materials with single-tooth implant-supported crowns in functional area. A metal experimental model with a dental implant was designed to receive in-office CAD/CAM-generated monoceramic crowns. Laterally positioned axial dynamic loading of 300 N at 2 Hz was applied to implant-supported crowns machined from 2 different glass materials for 100,000 cycle. Failures in terms of fracture, crack formation, and chipping were macroscopically recorded and microscopically evaluated. Four of 10 aluminasilicate glass-ceramic crowns fractured at early loading cycles, the rest completed loading with a visible crack formation. Crack formation was recorded for 2 of 10 leucite glass-ceramic crowns. Others completed test without visible damage but fractured upon removal. Lack in chemical adhesion between titanium abutment and dental cement likely reduces the fatigue resistance of machinable glass-ceramic materials. However, relatively better fractural strength of leucite glass-ceramics could be taken into consideration. Accordingly, progress on developmental changes in filler composition of glass-ceramics may be promising. Machinable glass-ceramics do not possess sufficient fatigue resistance for single-tooth implant crowns in functional area.

  14. Cemented versus screw-retained implant-supported single-tooth crowns: a 10-year randomised controlled trial.

    Science.gov (United States)

    Vigolo, Paolo; Mutinelli, Sabrina; Givani, Andrea; Stellini, Edoardo

    2012-01-01

    The purpose of this randomised controlled trial was to compare the long-term clinical outcome of cemented and screw-retained implant-supported single-tooth crowns. Eighteen consecutive patients presenting with single-tooth bilateral edentulous sites in the canine/molar region with adequate bone width, similar bone height at the implant sites, and an occlusal scheme that allowed for the establishment of identical occlusal cusp/fossa contacts were treated. Each patient received two identical implants according to a split-mouth design. One side was randomly selected to be restored with a cemented implant-supported single crown, and the other was restored with a screw-retained implant-supported single crown. Outcome measures were implant success, complications, marginal bone levels and peri-implant soft tissue health. Ten years after initial loading, 2 patients moved away and were lost to follow-up. Two implants placed in the same patient failed 5 years after their insertion; the remaining 30 implants survived, resulting in a cumulative implant success rate of 93.7%. No complication occurred. The mean marginal bone resorption at 10 years after implant placement, measured on intraoral radiographs, was 1.1 ± 0.2 mm for both types of restorations. There were no statistically significant differences between the two groups with respect to peri-implant marginal bone level at the 10-year follow-up appointment (T2) (P = 0.58); at the 4-year follow-up appointment (T1) a statistically significant difference was observed (P = 0.01), but this was not considered clinically relevant (mean difference: -0.06 mm). The status of the soft tissue around the implants remained stable over the evaluation period. No statistically significant difference was identified for the facial keratinised gingiva between the two groups at T1 (P = 0.10) or at T2 (P = 0.07). Within the limitations of this study, the results indicate that there was no evidence of a significant difference in the clinical

  15. Autogenous tooth transplantation for replacing a lost tooth: case reports

    Directory of Open Access Journals (Sweden)

    Ji-Youn Kang

    2013-02-01

    Full Text Available The autogenous tooth transplantation is an alternative treatment replacing a missing tooth when a suitable donor tooth is available. It is also a successful treatment option to save significant amount of time and cost comparing implants or conventional prosthetics. These cases, which required single tooth extraction due to deep caries and severe periodontal disease, could have good results by transplanting non-functional but sound donor tooth to the extraction site.

  16. A 1-year randomised controlled trial comparing zirconia versus metal-ceramic implant supported single-tooth restorations

    DEFF Research Database (Denmark)

    Hosseini, Mandana; Worsaae, Nils; Schiødt, Morten

    2011-01-01

    PURPOSE: To compare the biological, technical and aesthetic outcomes of single implant-supported all-ceramic versus metal-ceramic crowns. MATERIALS AND METHODS: Thirty-six patients with premolar agenesis were randomly treated with 38 all-ceramic (AC) and 37 metal-ceramic (MC) implant......-supported single-tooth restorations. A quasi-randomisation of consecutively included restorations in patients with one or more implants was used, i.e. a combination of parallel group (for 13 patients with one restoration) and split-mouth (for 23 patients with =2 restorations). All patients were recalled......, by blinded assessors. RESULTS: One-year after loading, no patient dropped out and no implant failed, though one MC restoration had to be remade. The marginal bone loss was not significantly different between AC and MC restorations (AC: mean 0.08 mm, SD 0.25; MC: mean 0.10 mm, SD 0.17). Seven out of 10...

  17. Shape recovery mechanism observed in single crystals of shape memory alloys

    Czech Academy of Sciences Publication Activity Database

    Seiner, Hanuš; Sedlák, Petr; Landa, Michal

    2008-01-01

    Roč. 81, č. 6 (2008), s. 537-551 ISSN 0141-1594 Institutional research plan: CEZ:AV0Z20760514 Keywords : shape memory alloy s * shape recovery process * martensitic microstructure * non-classical boundaries Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.201, year: 2008

  18. Comparison of implant versus tooth-supported zirconia-based single crowns in a split-mouth design: a 4-year clinical follow-up study.

    Science.gov (United States)

    Güncü, Mustafa Barış; Cakan, Umut; Aktas, Guliz; Güncü, Güliz Nigar; Canay, Şenay

    2016-12-01

    This study aims to evaluate the 4-year clinical performance of tooth versus implant-supported single-unit zirconia crowns (LAVA™) placed on posterior region. Twenty-four patients (10 men and 14 women) who had received 48 single crowns (24 implant-supported and 24 tooth-supported) from January 2007 to December 2009, were included. California Dental Association (CDA) quality assessment system, plaque and gingival index scores were used to evaluate the performance of the crowns at baseline and at all follow-up examinations. During the follow-up period, no fracture of zirconia coping has occurred. Major complication was chipping in three patients that required a new crown fabrication. Except for the failure ones, all crowns in both groups were rated as satisfactory at the follow-up examinations based on the CDA quality assessment criteria. There were no statistically significant differences between tooth and implant-supported crowns in terms of periodontal parameters. The present 4-year follow-up clinical study demonstrates that single-unit tooth- and implant-supported zirconia crowns have similar prosthetic and periodontal outcomes. Single-unit implant or tooth-supported zirconia crowns may be considered acceptable treatment modalities for restoration of either missing or compromised posterior teeth.

  19. Lineage-specific responses of tooth shape in murine rodents (murinae, rodentia to late Miocene dietary change in the Siwaliks of Pakistan.

    Directory of Open Access Journals (Sweden)

    Yuri Kimura

    Full Text Available Past ecological responses of mammals to climate change are recognized in the fossil record by adaptive significance of morphological variations. To understand the role of dietary behavior on functional adaptations of dental morphology in rodent evolution, we examine evolutionary change of tooth shape in late Miocene Siwalik murine rodents, which experienced a dietary shift toward C4 diets during late Miocene ecological change indicated by carbon isotopic evidence. Geometric morphometric analysis in the outline of upper first molars captures dichotomous lineages of Siwalik murines, in agreement with phylogenetic hypotheses of previous studies (two distinct clades: the Karnimata and Progonomys clades, and indicates lineage-specific functional responses to mechanical properties of their diets. Tooth shapes of the two clades are similar at their sympatric origin but deviate from each other with decreasing overlap through time. Shape change in the Karnimata clade is associated with greater efficiency of propalinal chewing for tough diets than in the Progonomys clade. Larger body mass in Karnimata may be related to exploitation of lower-quality food items, such as grasses, than in smaller-bodied Progonomys. The functional and ecophysiological aspects of Karnimata exploiting C4 grasses are concordant with their isotopic dietary preference relative to Progonomys. Lineage-specific selection was differentially greater in Karnimata, and a faster rate of shape change toward derived Karnimata facilitated inclusion of C4 grasses in the diet. Sympatric speciation in these clades is most plausibly explained by interspecific competition on resource utilization between the two, based on comparisons of our results with the carbon isotope data. Interspecific competition with Karnimata may have suppressed morphological innovation of the Progonomys clade. Pairwise analyses of morphological and carbon isotope data can uncover ecological causes of sympatric speciation

  20. Lineage-specific responses of tooth shape in murine rodents (murinae, rodentia) to late Miocene dietary change in the Siwaliks of Pakistan.

    Science.gov (United States)

    Kimura, Yuri; Jacobs, Louis L; Flynn, Lawrence J

    2013-01-01

    Past ecological responses of mammals to climate change are recognized in the fossil record by adaptive significance of morphological variations. To understand the role of dietary behavior on functional adaptations of dental morphology in rodent evolution, we examine evolutionary change of tooth shape in late Miocene Siwalik murine rodents, which experienced a dietary shift toward C4 diets during late Miocene ecological change indicated by carbon isotopic evidence. Geometric morphometric analysis in the outline of upper first molars captures dichotomous lineages of Siwalik murines, in agreement with phylogenetic hypotheses of previous studies (two distinct clades: the Karnimata and Progonomys clades), and indicates lineage-specific functional responses to mechanical properties of their diets. Tooth shapes of the two clades are similar at their sympatric origin but deviate from each other with decreasing overlap through time. Shape change in the Karnimata clade is associated with greater efficiency of propalinal chewing for tough diets than in the Progonomys clade. Larger body mass in Karnimata may be related to exploitation of lower-quality food items, such as grasses, than in smaller-bodied Progonomys. The functional and ecophysiological aspects of Karnimata exploiting C4 grasses are concordant with their isotopic dietary preference relative to Progonomys. Lineage-specific selection was differentially greater in Karnimata, and a faster rate of shape change toward derived Karnimata facilitated inclusion of C4 grasses in the diet. Sympatric speciation in these clades is most plausibly explained by interspecific competition on resource utilization between the two, based on comparisons of our results with the carbon isotope data. Interspecific competition with Karnimata may have suppressed morphological innovation of the Progonomys clade. Pairwise analyses of morphological and carbon isotope data can uncover ecological causes of sympatric speciation and define

  1. A prospective clinical study to evaluate the performance of zirconium dioxide dental implants in single-tooth gaps.

    Science.gov (United States)

    Gahlert, Michael; Kniha, Heinz; Weingart, Dieter; Schild, Sabine; Gellrich, Nils-Claudius; Bormann, Kai-Hendrik

    2016-12-01

    Dental implants have traditionally been made from titanium or its alloys, but recently full-ceramic implants have been developed with comparable osseointegration properties and functional strength properties to titanium. These ceramic implants may have advantages in certain patients and situations, for example, where esthetic outcomes are particularly important. The objective of this investigation was to evaluate the performance of a newly developed full-ceramic ZrO 2 monotype implant design (PURE Ceramic Implant; Institut Straumann AG, Basel, Switzerland) in single-tooth gaps in the maxilla and mandible. This was a prospective, open-label, single-arm study in patients requiring implant rehabilitation in single-tooth gaps. Full-ceramic implants were placed, with provisional and final prostheses inserted after 3 and 6 months, respectively. Crestal bone level was measured at implant placement and after 6 and 12 months. Implant survival and success were evaluated after 6 and 12 months. Further evaluations are planned after 24 and 36 months. Forty-six patients were screened for potential study participation, of whom 44 (17 men and 27 women, mean age 48 ± 14 years) were recruited into the study. The majority of implants (90.9%) were placed in the maxilla. The implant survival and implant success rate after 12 months were 97.6%. A minor change of the mean bone level occurred between implant loading (final prosthesis insertion after 6 months) and 12 months (-0.14 mm) after initial bone remodeling was observed between implant placement and loading (-0.88 mm). The results indicated that monotype ceramic implants can achieve clinical outcomes comparable to published outcomes of equivalent titanium implants. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. A single basis for developmental buffering of Drosophila wing shape.

    Directory of Open Access Journals (Sweden)

    Casper J Breuker

    2006-12-01

    Full Text Available The nature of developmental buffering processes has been debated extensively, based on both theoretical reasoning and empirical studies. In particular, controversy has focused on the question of whether distinct processes are responsible for canalization, the buffering against environmental or genetic variation, and for developmental stability, the buffering against random variation intrinsic in developmental processes. Here, we address this question for the size and shape of Drosophila melanogaster wings in an experimental design with extensively replicated and fully controlled genotypes. The amounts of variation among individuals and of fluctuating asymmetry differ markedly among genotypes, demonstrating a clear genetic basis for size and shape variability. For wing shape, there is a high correlation between the amounts of variation among individuals and fluctuating asymmetry, which indicates a correspondence between the two types of buffering. Likewise, the multivariate patterns of shape variation among individuals and of fluctuating asymmetry show a close association. For wing size, however, the amounts of individual variation and fluctuating asymmetry are not correlated. There was a significant link between the amounts of variation between wing size and shape, more so for fluctuating asymmetry than for variation among individuals. Overall, these experiments indicate a considerable degree of shared control of individual variation and fluctuating asymmetry, although it appears to differ between traits.

  3. Clinical and radiographic outcome following immediate loading and delayed loading of single-tooth implants: Randomized clinical trial.

    Science.gov (United States)

    Gjelvold, Björn; Kisch, Jenö; Chrcanovic, Bruno Ramos; Albrektsson, Tomas; Wennerberg, Ann

    2017-06-01

    Immediate loading of single implants is generally considered a reliable procedure. The objective of the present prospective randomized clinical study was to compare the overall treatment outcome following immediate loading (IL) and delayed loading (DL) of single implants after 1 year of follow-up. Patients with a missing maxillary tooth (15-25) were randomly assigned to IL or DL. The protocol included implant installation in healed sites, immediate loading, delayed loading, temporary screw-retained restoration, and replacement with a permanent single implant crown. Outcome measures were implant survival, marginal bone level, soft tissue changes, papillae index, pink, and white esthetic score (PES and WES), patient judged aesthetics, and oral health impact profile (OHiP-14). Implant survival rate was 100% and 96% for IL and DL, respectively. Implant success rate was 96% and 88% for IL and DL, respectively. Statistically significant lower papilla index scores were found in the IL group at temporary crown and definitive crown placement. An overall statistically significant improvement after 12 months for PES, WES and OHIP-14 was found. This prospective randomized study showed that single implants in the maxilla can present satisfactory results with respect to either immediate loading or delayed loading after 12 months. © 2017 Wiley Periodicals, Inc.

  4. Fracture resistance of single-tooth implant-supported zirconia-based indirect composite-layered molar restorations.

    Science.gov (United States)

    Taguchi, Kohei; Komine, Futoshi; Fushiki, Ryosuke; Blatz, Markus B; Kamio, Shingo; Matsumura, Hideo

    2014-08-01

    This study evaluated the fracture resistance of single-tooth implant-supported zirconia-based indirect composite-layered molar restorations. Forty-four titanium abutments (GingiHue Post) were placed on dental implants (Osseotite Implant). Standardized single-tooth cement-retained implant-supported mandibular molar restorations were fabricated for each of four test groups (n = 11) as follows: porcelain-fused-to-metal crowns (PFM), zirconia-based all-ceramic crowns (ZAC), zirconia-based indirect composite-layered crowns primed with Estenia Opaque Primer for zirconia frameworks (ZIC-E), and zirconia-based indirect composite-layered crowns (ZIC). The crowns were luted with a glass-ionomer cement (Ketac Cem Easymix). Fracture resistance (N) was determined by force application of a perpendicular load to the crowns with a universal testing machine. One-way analysis of variance (ANOVA) and the Tukey's HSD test were used to assess differences in fracture resistance values (α = 0.05). Mean fracture resistances (SD) were 3.09 (0.22) kN, 3.11 (0.34) kN, 2.84 (0.21) kN, and 2.50 (0.36) kN for the PFM, ZAC, ZIC-E, and ZIC groups, respectively. Fracture resistance in the ZIC specimens was significantly lower (P zirconia-based indirect composite-layered molar crowns primed with Estenia Opaque Primer for zirconia frameworks (ZIC-E) is comparable to that of porcelain-fused-to-metal (PFM) and zirconia-based all-ceramic (ZAC) restorations. Application of Estenia Opaque Primer to zirconia ceramic framework provides superior fracture resistance in implant-supported zirconia-based indirect composite-layered molar crowns. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. A T-shape linear piezoelectric motor with single foot.

    Science.gov (United States)

    Liu, Yingxiang; Chen, Weishan; Yang, Xiaohui; Liu, Junkao

    2015-02-01

    A new T-shape piezoelectric motor using the hybrid of two orthogonal longitudinal vibrations is proposed in this work. Six pieces of PZT ceramic plates are bonded on the upside and downside surfaces of a T-shape duralumin alloy base respectively to form the proposed motor. Elliptical movement can be generated on the driving tip by applying sine and cosine voltages to the PZT elements. The horizontal displacement of the driving tip will push the runner while the vertical displacement can overcome the preload. Finite element method is used to accomplish the design and analysis process. The resonance frequencies of the two vibration modes are tuned to be close by modal analysis, while the motion trajectory of the driving tip is observed by transient analysis. After the fabrication of a prototype, the vibration characteristics and mechanical output ability are measured. The no-load speed and the maximum output thrust force of the proposed motor are tested to be 718 mm/s and 3.5 N under an exciting frequency of 53.1 kHz. The proposed T-shape piezoelectric motor exhibits merits of simple structure, easy to realize miniaturization, easy to be fabricated, and high power-to-weight ratio. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Placement of single tooth implant in healed socket with immediate temporization: Clinical study

    Directory of Open Access Journals (Sweden)

    Jeevan Lata

    2012-01-01

    Full Text Available Introduction: Edentulous condition inadequately compensated for, by dentures, impair oral function and is accompanied by reduced self–confidence. In a continued effort to achieve these goals, implant dentistry was introduced. Immediate temporization is somehow a recent concept, which allows the maintenance of soft tissue contours, along with interdental alveolar contours. Aims and Obectives: Aims of the present study were to study the placement of implant in the post-extracted healed tooth socket of anterior maxilla and to evaluate the feasibility of early function on implants placed. Materials and Methods: In the present study, HI-TECH IMPLANTS TRX-OP one-piece immediate loading implant system with the built on abutment has been used.Immediate temporisation has been done and results have been evaluated in terms of stability, gingival health, esthetics, marginal bone loss, patient′s psychological attitude, and satisfaction.
Results: Out of eight implants, 6 successfully healed whereas 2 implants suffered failure
Conclusion: Overall conclusion drawn from the study is, immediate temporization is a successful method providing psychological, financial and emotional benefits to the patient.

  7. Shape transition of unstrained flattest single-walled carbon nanotubes under pressure

    Energy Technology Data Exchange (ETDEWEB)

    Mu, Weihua, E-mail: whmu@mit.edu, E-mail: muwh@itp.ac.cn [Department of Chemistry, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); State Key Laboratory of Theoretical Physics, Institute of Theoretical Physics, The Chinese Academy of Sciences, P. O. Box 2735 Beijing 100190 (China); Kavli Institute for Theoretical Physics China, The Chinese Academy of Sciences, P. O. Box 2735 Beijing 100190 (China); Cao, Jianshu, E-mail: jianshu@mit.edu [Department of Chemistry, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Singapore-MIT Alliance for Research and Technology (SMART), Singapore 138602 (Singapore); Ou-Yang, Zhong-can [State Key Laboratory of Theoretical Physics, Institute of Theoretical Physics, The Chinese Academy of Sciences, P. O. Box 2735 Beijing 100190 (China); Kavli Institute for Theoretical Physics China, The Chinese Academy of Sciences, P. O. Box 2735 Beijing 100190 (China); Singapore-MIT Alliance for Research and Technology (SMART), Singapore 138602 (Singapore); Center for Advanced Study, Tsinghua University, Beijing 100084 (China)

    2014-01-28

    Single walled carbon nanotube's (SWCNT's) cross section can be flattened under hydrostatic pressure. One example is the cross section of a single walled carbon nanotube successively deforms from the original round shape to oval shape, then to peanut-like shape. At the transition point of reversible deformation between convex shape and concave shape, the side wall of nanotube is flattest. This flattest tube has many attractive properties. In the present work, an approximate approach is developed to determine the equilibrium shape of this unstrained flattest tube and the curvature distribution of this tube. Our results are in good agreement with recent numerical results, and can be applied to the study of pressure controlled electric properties of single walled carbon nanotubes. The present method can also be used to study other deformed inorganic and organic tube-like structures.

  8. Single-tooth replacement in the anterior maxilla by means of immediate implantation and provisionalization: a review.

    Science.gov (United States)

    De Rouck, Tim; Collys, Kristiaan; Cosyn, Jan

    2008-01-01

    The objective of this study was to assess to what extent the outcome of immediate implantation and provisionalization for replacing single maxillary teeth in the esthetic zone is favorable and predictable from biologic and esthetic points of view. An electronic search (MEDLINE and Cochrane Oral Health Group Specialized Trials Register) and a manual search were performed to detect studies concerning maxillary single-tooth replacements by means of dental implants immediately placed into fresh extraction sockets and provisionalized within the first 24 hours. Only full-text reports on clinical studies published in English up to June 2006 were included. Case reports and reviews on the topic of interest were excluded. Eleven studies were selected. Based on a qualitative data analysis, implant survival and even management of papilla levels seem predictable following immediate implantation and provisionalization. However, maintaining the midfacial gingival margin may be more problematic, since postextraction bone remodeling and therefore marginal gingival changes will occur irrespective of the timing of the placement of an implant. The long-term impact of this remodeling is currently unclear and needs to be elucidated in future research. The clinician is recommended to be reserved when considering immediate implant placement and provisionalization for replacing single maxillary teeth in the anterior zone. At the very least, a number of guidelines and prerequisites need to be taken into consideration.

  9. Dissimilar friction stir welding of 6061 Al to T2 pure Cu adopting tooth-shaped joint configuration: Microstructure and mechanical properties

    International Nuclear Information System (INIS)

    Zhang, Wei; Shen, Yifu; Yan, Yinfei; Guo, Rui

    2017-01-01

    In this paper, dissimilar 6061aluminum alloy and commercial pure copper were friction stir butt welded adopting tooth-shaped joint configuration to investigate the influence of Al/Cu content in welding bead (WB) on the microstructure and mechanical properties of the joint. At preliminary tests, optimal welding parameters were determined to guarantee proper heat input. Welding experiments were performed with the dimensions of the tooth as variables, which is a special technique to tailor Al/Cu content in WB. Macro and microstructure of the cross section of the joints were characterized via optical microscopy (OM) and Scanning Electron Microscopy (SEM) equipped with energy dispersive spectroscopy (EDS). Special band structure(BS) showing lamellar-like flow characteristic is worthy of noticing. Additionally, dispersive Cu particles (DP), forming composite-like structure, were captured. High Cu concentration, however, yielded a harsh material flow due to its high plasticized temperature and poor flowability and can not produce reliable metallurgical bonding. Microhardness of the joint was investigated and the high hardness was caused mainly by the hard intermetallic compounds (IMCs). Besides, tensile tests were conducted to evaluate the joint performance. Based on the result analysis, this joint form has special advantage in tailoring Al/Cu content in WB and controlling the microstructure that imposes significant influence on mechanical properties of the joints.

  10. Evaluation of aesthetics of implant-supported single-tooth replacements using different bone augmentation procedures : A prospective randomized clinical study

    NARCIS (Netherlands)

    Meijndert, Leo; Meijer, Henny J. A.; Stellingsma, Kees; Stegenga, Boudewijn; Raghoebar, Gerry M.

    2007-01-01

    Objectives: The aim of this study was to evaluate the aesthetics of implant-supported single-tooth replacements using different augmentation procedures in a prospective study with the use of an objective rating index and with a subjective patient questionnaire, and to compare the results with each

  11. Comparison of procedures for immediate reconstruction of large osseous defects resulting from removal of a single tooth to prepare for insertion of an endosseous implant after healing

    NARCIS (Netherlands)

    Raghoebar, G. M.; Slater, J. J. H.; den Hartog, L.; Meijer, H. J. A.; Vissink, A.

    This study evaluated the treatment outcome of immediate reconstruction of 45 large osseous defects resulting from removal of a single tooth with a 1:2 mixture of Bio-Oss(R) and autologous tuberosity bone, and three different procedures for soft tissue closing (Bio-Gide(R) membrane, connective tissue

  12. Immediate placement and loading of maxillary single-tooth implants: a 3-year prospective study of marginal bone level.

    Science.gov (United States)

    Berberi, Antoine N; Noujeim, Ziad N; Kanj, Wasf H; Mearawi, Rita J; Salameh, Ziad A

    2014-03-01

    The purpose of this study was to evaluate marginal bone level around single-tooth implants placed in anterior maxilla and immediately restored. Twenty implants were placed in 20 patients (8 men and 12 women) that were selected for this study. Following atraumatic non-surgical extraction of tooth, all patients immediately received implants and the definitive prefabricated abutment was placed. Implant position was transferred to the scanning unit of the CAD/CAM system using prefabricated surgical guide. Temporary crowns were immediately fabricated and cemented. Eight weeks later final crowns were luted. Outcome assessment as implant survival and level of marginal bone radiographic evaluations were performed at 8 weeks, 1 and 3 years time period after loading. All implants placed osseointegrated successfully after 3 years of functional loading. The mean marginal bone loss was 0.16 mm (SD, 0.167 mm), 0.275 mm (SD, 0.171 mm) and 0.265 mm (SD, 0.171 mm) at 8 weeks, 1 and 3 years time period respectively. Four out of the 20 implants showed no bone loss. Immediate loading technique using the final abutment directly eliminated the need for a second stage surgery and prevented interruption of soft and hard tissue at implant neck, which resulted in better soft tissue response and reduced marginal bone loss. Clinical significance: Immediately loaded implants, in fresh extraction sockets by insertion of a provisional restoration on the titanium abutment without any later manipulation, helped to protect the initially forming blood clot and presented a template for soft tissue contouring that resulted in significant reduction of marginal bone resorption and maintenance of soft tissue architecture.

  13. Large pyramid shaped single crystals of BiFeO{sub 3} by solvothermal synthesis method

    Energy Technology Data Exchange (ETDEWEB)

    Sornadurai, D.; Ravindran, T. R.; Paul, V. Thomas; Sastry, V. Sankara [Condensed Matter Physics Division, Materials Science Group, Physical Metallurgy Division, Metallurgy and Materials Group, Indira Gandhi Centre for Atomic Research, Kalpakkam, Tamil Nadu (India); Condensed Matter Physics Division, Materials Science Group (India)

    2012-06-05

    Synthesis parameters are optimized in order to grow single crystals of multiferroic BiFeO{sub 3}. 2 to 3 mm size pyramid (tetrahedron) shaped single crystals were successfully obtained by solvothermal method. Scanning electron microscopy with EDAX confirmed the phase formation. Raman scattering spectra of bulk BiFeO3 single crystals have been measured which match well with reported spectra.

  14. Integrated shape and material selection for single and multi-performance criteria

    International Nuclear Information System (INIS)

    Singh, Jasveer; Mirjalili, Vahid; Pasini, Damiano

    2011-01-01

    Research highlights: → The method of shape transformers is extended to torsional stiffness and combined load design. → The method is generalized for multi-criteria selection of shape and material. → Performance charts are presented for single and multi-objective selection of cross-section shape and material. → A four quadrant performance chart is presented to visualize the relation between objective function space and design variable space. -- Abstract: A shape and material selection method, based on the concept of shape transformers, has been recently introduced to characterize the mass efficiency of lightweight beams under bending and shear. This paper extends this method to deal with the case of torsional stiffness design, and generalize it to single and multi-crieria selection of lightweight shafts subjected to a combination of bending, shear, and torsional load. The novel feature of the paper is the useful integration of shape and material to model and visualize multi-objective selection problems. The scheme is centered on concept selection in structural design, and hinges on measures that govern the shape properties of a cross-section regardless of its size. These measures, referred as shape transformers, can classify shapes in a way similar to material classification. The procedure is exemplified by considering torsional stiffness as a constraint. The performance charts are developed for single and multi-criteria to visualize in a glance the whole range of cross-sectional shapes for each material. Each design chart is explained with a brief example.

  15. A SINGLE VISIT IMMEDIATE TEMPORIZATION WITH NATURAL TOOTH PONTIC FOR PERIODONTALLY INVOLVED ANTERIOR TEETH : ANESTHETIC AND INNOVATIVE APPROACH

    Directory of Open Access Journals (Sweden)

    Nilofer Sultan Sheikh, Neelima S. Rajhans, Preeti Mundhe, Gabriela Jude Fernandez, Nilkanth Mhaske, Nikesh Moolya, Sudeep HM

    2015-01-01

    Full Text Available Aim and Objectives: Sudden loss of anterior tooth is a dreadful situation. It can be as a result of trauma, endodontic failure or periodontal disease which is a true aesthetic emergency for a patient. Along with the patient, the dentist also emphasizes on saving an anterior tooth for the primary reason of aesthetics. If the tooth crown is intact, is not grossly decayed, broken down or discoloured, it can be used as a natural tooth pontic in designing an interim prosthesis. Case: A chair side technique for replacing the missing tooth using the patient’s own natural tooth as a pontic in the three dimensional original position using a fibre reinforced composite resin splint thus restoring the aesthetics and relieving the apprehension of the patient, as described in this case report. Conclusion: The concept of Natural tooth pontic placement is a simple, economical, minimal intervention, viable and an easy to handle treatment option and promises an excellent transient aesthetic solution for a lost tooth as well as require minimal or no tooth preparation, thus is a reversible technique and avoids the laboratory cost.

  16. A SINGLE VISIT IMMEDIATE TEMPORIZATION WITH NATURAL TOOTH PONTIC FOR PERIODONTALLY INVOLVED ANTERIOR TEETH : ANESTHETIC AND INNOVATIVE APPROACH

    OpenAIRE

    Nilofer Sultan Sheikh, Neelima S. Rajhans, Preeti Mundhe, Gabriela Jude Fernandez, Nilkanth Mhaske, Nikesh Moolya, Sudeep HM

    2015-01-01

    Aim and Objectives: Sudden loss of anterior tooth is a dreadful situation. It can be as a result of trauma, endodontic failure or periodontal disease which is a true aesthetic emergency for a patient. Along with the patient, the dentist also emphasizes on saving an anterior tooth for the primary reason of aesthetics. If the tooth crown is intact, is not grossly decayed, broken down or discoloured, it can be used as a natural tooth pontic in designing an interim prosthesis. Case: A chair side ...

  17. Creating a Single-Visit, Fibre-Reinforced, Composite Resin Bridge by Using a Natural Tooth Pontic: A Viable Alternative to a PFM Bridge.

    Science.gov (United States)

    Khetarpal, Ambica; Talwar, Sangeeta; Verma, Mahesh

    2013-04-01

    The rehabilitation of an anterior tooth space presents a confronting situation. Several modalities are presently available to address the challenge of an immediate replacement of a missing anterior tooth. These include a removable temporary acrylic prosthesis or resin-bonded bridges. Fibre-Reinforced Composite (FRC) bridges are preferable if they are fixed and if a cost-effective tooth replacement is desired. Also, they provide an aesthetic and a conservative treatment choice as the abutment teeth require a minimal or no preparation. This article is describing two cases with an immediate replacement of the maxillary incisor teeth by a single visit technique, with the use of FRC Resin (Ribbond) bridges and natural tooth crowns as pontics. The procedure was completed at the chair side, thereby avoiding the laboratory costs. A two year follow up of the cases has shown a successful outcome. Creating an adhesive FRC bridge by using a natural tooth pontic is a successful treatment option for the direct aesthetic replacement of missing anterior teeth.

  18. Microstructure and Pinning Properties of Hexagonal Disc Shaped Single Crystalline MgB2

    Energy Technology Data Exchange (ETDEWEB)

    Patel, J. R.

    2003-04-30

    We synthesized hexagonal-disc-shaped MgB{sub 2} single crystals under high-pressure conditions and analyzed the microstructure and pinning properties. The lattice constants and the Laue pattern of the crystals from X-ray micro-diffraction showed the crystal symmetry of MgB{sub 2}. A thorough crystallographic mapping within a single crystal showed that the edge and c-axis of hexagonal-disc shape exactly matched the (10-10) and the (0001) directions of the MgB{sub 2} phase. Thus, these well-shaped single crystals may be the best candidates for studying the direction dependences of the physical properties. The magnetization curve and the magnetic hysteresis for these single crystals showed the existence of a wide reversible region and weak pinning properties, which supported our single crystals being very clean.

  19. Shape of isolated domains in lithium tantalate single crystals at elevated temperatures

    International Nuclear Information System (INIS)

    Shur, V. Ya.; Akhmatkhanov, A. R.; Baturin, I. S.; Chezganov, D. S.; Lobov, A. I.; Smirnov, M. M.

    2013-01-01

    The shape of isolated domains has been investigated in congruent lithium tantalate (CLT) single crystals at elevated temperatures and analyzed in terms of kinetic approach. The obtained temperature dependence of the growing domain shape in CLT including circular shape at temperatures above 190 °C has been attributed to increase of relative input of isotropic ionic conductivity. The observed nonstop wall motion and independent domain growth after merging in CLT as opposed to stoichiometric lithium tantalate have been attributed to difference in wall orientation. The computer simulation has confirmed applicability of the kinetic approach to the domain shape explanation

  20. In Vitro Assessment of Single-Retainer Tooth-Colored Adhesively Fixed Partial Dentures for Posterior Teeth

    Directory of Open Access Journals (Sweden)

    Tissiana Bortolotto

    2010-01-01

    Full Text Available The purpose of this paper was to investigate, by means of marginal adaptation and fracture strength, three different types of single retainer posterior fixed partial dentures (FPDs for the replacement of a missing premolar. Two-unit cantilever FPDs were fabricated from composite resin, feldspathic porcelain, and fiber-reinforced composite resin. After luting procedures and margin polishing, all specimens were subjected to a Scanning Electron Microscopic marginal evaluation both prior to and after thermomechanical loading with a custom made chewing simulator comprising both thermal and mechanical loads. The results indicated that the highest score of marginal adaptation, that is, the closest score to 100% of continuous margins, at the tooth-composite resin interface was attained by the feldspathic porcelain group (88.1% median, followed by the fiber-reinforced composite resin group (78.9% median. The worse results were observed in the composite resin group (58.05% median. Fracture strength was higher in feldspathic porcelain (196N median when compared to resin composite (114.9 N median. All the fixed prostheses made of fiber-reinforced composite resin detached from the abutment teeth before fracturing, suggesting that the adhesive surface's retainer should be increased.

  1. One-piece zirconia oral implants: one-year results from a prospective cohort study. 1. Single tooth replacement.

    Science.gov (United States)

    Kohal, Ralf-Joachim; Knauf, Marko; Larsson, Birgitta; Sahlin, Herman; Butz, Frank

    2012-06-01

    To investigate the clinical and radiographic outcome of a one-piece zirconia oral implant for single tooth replacement after 1 year. A total of 65 patients received a one-stage implant surgery with immediate temporization. Standardized radiographs were taken at implant insertion and after 1 year to monitor peri-implant bone loss. A univariate analysis of the influence of different baseline parameters on marginal bone loss from implant insertion to 12 months was performed. Soft tissue parameters were evaluated at prosthesis insertion and at the 1-year follow-up. After 1 year, three implants were lost, giving a cumulative survival rate of 95.4%. The marginal bone loss after 1 year was 1.31 mm. Thirty-four per cent of the implants lost at least 2 mm bone, and 14% more than 3 mm. The univariate analysis could not depict any parameter influencing marginal bone loss. Probing depth, Clinical Attachment Level, Bleeding and Plaque Index decreased over 1 year. The cumulative survival rate of the presented ceramic implant was comparable to the reported survival rate of titanium implants when immediately restored. However, the frequency of increased radiographic bone loss (>2 mm) after 1 year was considerably higher as compared to conventional two-piece titanium implants. The presented zirconia implant can therefore not be recommended for clinical usage. © 2012 John Wiley & Sons A/S.

  2. Immediate provisional restoration of a single-tooth implant in the esthetic zone: A case report

    Directory of Open Access Journals (Sweden)

    Po-Sung Fu

    2011-02-01

    Full Text Available Immediate implant restoration of single implants may demonstrate a positive effect on peri-implant soft tissue. Placement of a provisional restoration following implant surgery can create soft tissue contours that resemble normal gingival topography before placement of the definitive prosthesis. This article describes a staged approach of the mandibular permanent right central incisor, which was congenital missing. The proper space for restoration of the missing incisor was created through orthodontic treatment. The scheduled implant site was reconstructed using autogenous bone harvested from the chin region. After a healing period of four months, an implant was installed with the connection of a fixed provisional crown to a prefabricated temporary abutment. The soft tissue around the implant healed according to the contours of the provisional restoration and the emergence profile was used to duplicate the definitive restoration. Peri-implant esthetics was achieved through the staged approach and immediate restoration of the implant.

  3. Case presentation of two patients using diagonal platform-switched double implants for maxillary single-first-molar replacement as the alternative of a single-tooth implant.

    Science.gov (United States)

    Hotta, Yasunori; Ito, Koji; Komatsu, Shinichi; Saito, Takashi

    2015-12-01

    A single-tooth implant restoration is generally performed for maxillary single-first-molar replacement. If the interdental space between the second premolar and the second molar is large enough, a double-implant placement can be performed to avoid creating mesiodistal cantilever and to distribute occlusal loading forces.If there is not adequate space for a double-implant placement to be performed mesiodistally along the crest of the alveolar ridge line, they should be placed along a diagonal line offset lingually to increase the space. This procedure has two primary advantages. First, greater stability is provided by a double-implant placement. Resistance to lateral forces (palatal-buccal) is much stronger than two implants placed along the alveolar crest ridge line. Residual palatal and buccal bone can provide support against occlusal forces, provided that there is adequate residual bone in these regions.If anatomical conditions are favorable, the placement of two diagonal implants in the palatal and buccal residual bones can be a rational procedure.We report on two typical patients. The progress of these patients was followed using computed tomography for 7 and 6 years, respectively.

  4. Effect of immediate functional loading on osseointegration of implants used for single tooth replacement. A human histological study.

    Science.gov (United States)

    Donati, Mauro; Botticelli, Daniele; La Scala, Vincenzo; Tomasi, Cristiano; Berglundh, Tord

    2013-07-01

    To analyze hard tissue reactions to immediate functionally loaded single implants that were installed either with a conventional drill preparation procedure or with an osteotome preparation technique. Thirteen subjects with two sites requiring single tooth rehabilitation by means of implants volunteered for the study. Each subject received one test (immediate functionally loaded) and one control (non-loaded) implant. In six subjects (group 1) the implants were placed using a conventional drilling procedure, whereas in the remaining seven subjects (group 2) an osteotome preparation procedure was performed. Block biopsies containing test and control implants and peri-implant bone tissues were collected at 1 month in four of the subjects in group 1 and in five subjects of group 2. The remaining implant sites were sampled at 3 months after implant placement. The biopsies were prepared for histological examination. Two implants of the test-2 group (osteotome preparation) representing 1 month of healing and another test-2 implant representing 3 months of healing failed to integrate. A multilevel multivariate statistical analysis demonstrated that no differences in bone-to-implant contact (BIC)% were found in between test and control implants, the density of newly formed peri-implant bone was significantly higher around test than control implants at 1 and 3 months of healing. Sections representing osteotome technique sites showed fractured trabeculae and large amounts of bone particles. It is suggested that immediate loading of implants does not influence the osseointegration process, whereas the density of newly formed peri-implant bone at such sites appears to be increased in relation to unloaded control implants. The use of an osteotome preparation technique during installation results in damage of peri-implant bone and enhances the risk for failure in osseointegration. © 2012 John Wiley & Sons A/S.

  5. Zirconia and titanium implant abutments for single-tooth implant prostheses after 5 years of function in posterior regions.

    Science.gov (United States)

    Lops, Diego; Bressan, Eriberto; Chiapasco, Matteo; Rossi, Alessandro; Romeo, Eugenio

    2013-01-01

    To verify, in a medium-term follow-up, whether or not zirconia (Zr) abutments show similar survival outcomes as titanium (Ti) abutments in posterior areas. A two-stage surgical protocol was used. Each patient was followed for 5 years after the definitive prosthesis insertion. Clinical and radiographic parameters were assessed at the yearly follow-up visit, and prosthetic complications were recorded. Statistical analysis (Wilcoxon signed rank test) was used to compare any difference in biologic and radiographic parameters between implants and the natural contralateral teeth. Descriptive statistics were used to analyze the changes over time (from baseline to the last follow-up) of clinical and radiographic parameters. A total of 85 patients with a single posterior tooth gap were treated with 85 implants supporting 47 Ti and 38 Zr abutments, respectively. All-ceramic (38) and metal-ceramic (47) single crowns were fabricated. Four patients were classified as dropouts. Eighty-one implants supporting 44 Ti and 37 Zr abutments completed the 5-year follow-up examination. No implant, reconstruction, or abutment failures were recorded. Therefore, the prosthetic survival after 5 years of function was 100% for all the abutments and restorations. No significant differences in biologic and radiographic indexes were found between Ti and Zr abutments when compared with each other and with the natural teeth after 5 years. No significant marginal bone loss was found between the baseline and the last follow-up, both for Zr and Ti abutments. The medium-term survival of Zr abutments in posterior regions was comparable with that of Ti abutments. Long-term evaluations are needed to confirm this finding.

  6. Long-term cumulative survival and mechanical complications of single-tooth Ankylos Implants: focus on the abutment neck fractures.

    Science.gov (United States)

    Shim, Hye Won; Yang, Byoung-Eun

    2015-12-01

    To evaluate the cumulative survival rate (CSR) and mechanical complications of single-tooth Ankylos® implants. This was a retrospective clinical study that analyzed 450 single Ankylos® implants installed in 275 patients between December 2005 and December 2012. The main outcomes were survival results CSR and implant failure) and mechanical complications (screw loosening, fracture, and cumulative fracture rate [CFR]). The main outcomes were analyzed according to age, sex, implant length or diameter, bone graft, arch, and position. The 8-year CSR was 96.9%. Thirteen (2.9%) implants failed because of early osseointegration failure in 3, marginal bone loss in 6, and abutment fracture in 4. Screw loosening occurred in 10 implants (2.2%), and 10 abutment fractures occurred. All abutment fractures were located in the neck, and concurrent screw fractures were observed. The CSR and rate of screw loosening did not differ significantly according to factors. The CFR was higher in middle-aged patients (5.3% vs 0.0% in younger and older patients); for teeth in a molar position (5.8% vs 0.0% for premolar or 1.1% for anterior position); and for larger-diameter implants (4.5% for 4.5 mm and 6.7% for 5.5 mm diameter vs 0.5% for 3.5 mm diameter) (all Ptooth restoration in Koreans. However, relatively frequent abutment fractures (2.2%) were observed and some fractures resulted in implant failures. Middle-aged patients, the molar position, and a large implant diameter were associated with a high incidence of abutment fracture.

  7. Retrospective clinical study of 988 dual acid-etched implants placed in grafted and native bone for single-tooth replacement.

    Science.gov (United States)

    Sesma, Newton; Pannuti, Cláudio Mendes; Cardaropoli, Giuseppe

    2012-01-01

    To evaluate the influence of sex, implant characteristics, and bone grafting on the survival rate of dual acid-etched (DAE) implants. Patients treated with internal-hex DAE implants for single tooth replacement in a military dental clinic between January 2005 and December 2010 were included in this study. Clinical data related to implant characteristics, implant location, presence of grafted bone, and implant failures were collected. The primary outcome was implant loss. The survival rate was analyzed using the Kaplan-Meier method. Cox regression modeling was used to determine which factors would predict implant failure. DAE implants were evaluated in a total of 988 patients (80.3% men). Twenty-four (2.4%) implants failed, most were cylindric (54.2%) with regular platforms (70.8%) and were 10 mm long (58.3%). The failure rate was 2.4% for the anterior maxilla, 3.3% for the posterior maxilla, 1.6% for the anterior mandible, and 2.0% for posterior mandible. The cumulative survival rate was 97.6%. The failure rate was 8.8% in implants placed after sinus augmentation, 7.3% in bone block-grafted areas, and 1.6% in native bone. Based on multivariable analysis (Cox regression), sinus augmentation and bone block grafting had a statistically significant effect on implant failure; the hazard ratios were 5.5 and 4.6, respectively. The results revealed that DAE implants had high survival rates, and no influence of sex, location, shape, diameter, or length on failure rates could be observed. However, a significant association was observed between failure and presence of bone graft in the implant area.

  8. Tooth extraction

    Science.gov (United States)

    ... several teeth using the methods above. For an impacted tooth , the surgeon may have to cut a flap ... loosens or damages teeth Tooth injury from trauma Impacted teeth that are causing problems, such as wisdom teeth ( ...

  9. Tooth anatomy

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/002214.htm Tooth anatomy To use the sharing features on this page, ... upper jawbone is called the maxilla. Images Tooth anatomy References Chan S, Alessandrini EA. Dental injuries. In: Selbst ...

  10. Clinical Outcome of Inter-Proximal Papilla between a Tooth and a Single Implant Treated with CAD/CAM Abutments: a Cross-Sectional Study

    Directory of Open Access Journals (Sweden)

    Tiago Borges

    2012-09-01

    Full Text Available Objectives: The aim of this study was to assess the clinical outcomes achieved with Computer-Assisted Design/Computer-Assisted Manufacturing implant abutments in the anterior maxilla.Material and Methods: Nineteen patients with a mean age of 41 (range form 26 to 63 years, treated with 21 single tooth implants and 21 Computer-Assisted Design/Computer-Assisted Manufacturing (CAD/CAM abutments in the anterior maxillary region were included in this study. The patients followed 4 criteria of inclusion: (1 had a single-tooth implant in the anterior maxilla, (2 had a CAD/CAM abutment, (3 had a contralateral natural tooth, (4 the implant was restored and in function for at least 6 months up to 2 years. Cases without contact point were excluded. Presence/absence of the interproximal papilla, inter tooth-implant distance (ITD and distance from the base of the contact point to dental crest bone of adjacent tooth (CPB were accessed. Results: Forty interproximal spaces were evaluated, with an average mesial CPB of 5.65 (SD 1.65 mm and distal CPB of 4.65 (SD 1.98 mm. An average mesial ITD of 2.49 (SD 0.69 mm and an average distal ITD of 1.89 (SD 0.63 mm were achieved. Papilla was present in all the interproximal spaces accessed. Conclusions: The restoration of dental implants using CAD/CAM abutments is a predictable treatment with improved aesthetic results. These type of abutments seem to help maintaining a regular papillary filling although the variations of the implant positioning or the restoration teeth relation.

  11. Impact of extracorporeal shockwave therapy on tooth mobility in adult orthodontic patients: a randomized single-center placebo-controlled clinical trial.

    Science.gov (United States)

    Falkensammer, Frank; Rausch-Fan, Xiaohui; Schaden, Wolfgang; Kivaranovic, Danijel; Freudenthaler, Josef

    2015-03-01

    This RCT investigated the effect of non-invasive extracorporeal shockwaves on tooth mobility in orthodontic patients after active treatment. Seventy-two adult patients were included in the study. Immediately after active orthodontic treatment, patients were assigned to a treatment or a placebo group based on block randomization. The orthodontic patients were required to be otherwise healthy. The region of interest was the anterior portion of the mandible. The treatment group received a single shockwave treatment with 1000 impulses while the placebo group was treated with an acoustic sham. Tooth mobility was evaluated over a period of 6 months using a Periotest and manual testing. Pocket probing depths, bleeding on probing and the irregularity index were also assessed. Tooth mobility reduced significantly over 6 months in both groups, but shockwaves achieved significantly more rapid reduction on manual testing. Probing depth was significantly reduced while the irregularity index remained stable. Bleeding on probing was significantly reduced in the treatment group. No anti-inflammatory effect could be derived due to possible initial group differences. The mobility of teeth aligned by orthodontic treatment reduces over time. Shockwave treatment appeared to reduce tooth mobility more rapidly. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Building the Nanoplasmonics Toolbox Through Shape Modeling and Single Particle Optical Studies

    Science.gov (United States)

    Ringe, Emilie

    Interest in nanotechnology is driven by unprecedented properties tailorability, achievable by controlling particle structure and composition. Unlike bulk components, minute changes in size and shape affect the optical and electronic properties of nanoparticles. Characterization of such structure-function relationships and better understanding of structure control mechanisms is crucial to the development of applications such as plasmonic sensors and devices. The objective of the current research is thus twofold: to theoretically predict and understand how shape is controlled by synthesis conditions, and to experimentally unravel, through single particle studies, how shape, composition, size, and surrounding environment affect plasmonic properties in noble metal particles. Quantitative, predictive rules and fundamental knowledge obtained from this research contributes to the "nanoplasmonics toolbox", a library designed to provide scientists and engineers the tools to create and optimize novel nanotechnology applications. In this dissertation, single particle approaches are developed and used to unravel the effects of size, shape, substrate, aggregation state and surrounding environment on the optical response of metallic nanoparticles. Ag and Au nanocubes on different substrates are first presented, followed by the discussion of the concept of plasmon length, a universal parameter to describe plasmon energy for a variety of particle shapes and plasmon modes. Plasmonic sensing (both refractive index sensing and surface-enhanced Raman spectroscopy) and polarization effects are then studied at the single particle level. In the last two Chapters, analytical shape models based on the Wulff construction provide unique modeling tools for alloy and kinetically grown nanoparticles. The former reveals a size-dependence of the shape of small alloy particles (such as those used in catalysis) because of surface segregation, while the latter uniquely models the shape of many

  13. Esthetic Assessment of Implants Placed into Fresh Extraction Sockets for Single-Tooth Replacements Using a Flapless Approach.

    Science.gov (United States)

    Kolerman, Roni; Mijiritsky, Eitan; Barnea, Eitan; Dabaja, Areeje; Nissan, Joseph; Tal, Haim

    2017-04-01

    To validate the concept of immediate implant placement and nonfunctional loading for use in the esthetically sensitive anterior maxilla, clinical trials should ideally include objective esthetic criteria. This study analyzed procedural results as graded by the pink esthetic score and white esthetic score (PES/WES). Thirty-nine suitable patients (mean follow-up 44.82 ± 28 months) were evaluated. Thirty-eight implants fulfilled stringent criteria for successful osseointegration: absence of peri-implant radiolucency, implant mobility, suppuration, and pain. The mean total PES/WES was 15.50 ± 2.67 (range: 10-20). The mean total PES of 7.92 ± 1.60 (range: 5-10) indicated favorable overall peri-implant soft-tissue conditions. Root convexity and texture (1.63 ± 0.54) and curvature of the facial mucosa (1.68 ± 0.47) and distal papilla (1.66 ± 0.48) had the highest mean values, whereas acceptable levels of facial tissue (1.53 ± 0.73) and mesial papilla (1.42 ± 0.64) were the most difficult to fully achieve. The mean mesial and distal bone loss at data collection was, was 1.19 ± 0.54 and 1.15 ± 0.51, respectively. Periodontal disease severity (advanced chronic and aggressive periodontitis) was significantly associated with a low total PES (p = .048). Objective PES/WES assessment validated immediate anterior maxillary single-tooth replacement and restoration as being a successful and esthetically predictable treatment modality in sites where the buccal bone had been preserved during the extraction at 1 year of follow-up. © 2016 Wiley Periodicals, Inc.

  14. Compatible CAD-CAM titanium abutments for posterior single-implant tooth replacement: A retrospective case series.

    Science.gov (United States)

    Hsu, Kuang-Wei; Shen, Yu-Fu; Wei, Pein-Chi

    2017-03-01

    In addition to the original abutments provided by implant companies, compatible computer-aided design and computer-aided manufacturing (CAD-CAM) abutments are also available from different manufacturers. However, the combination of abutments and implant systems from different manufacturers may lead to mechanical problems between components. Little has been reported on the clinical performance of this treatment option. The purpose of this retrospective case series was to evaluate the outcome of compatible CAD-CAM titanium abutments (TiAs) for posterior single-implant tooth replacement (PSITR) up to 6 years after insertion. Eighty-one patients (34 men, 47 women) who received PSITR restored with compatible CAD-CAM TiAs and had a final recall examination between May 2014 and April 2015 were included in this study. Clinical and radiographic examinations were documented. Retrospective evaluation of the patient records was also performed. Correlations between bone-level changes and variables were calculated using the Spearman correlation. Implant and prosthesis survival rates were 100%. Twenty technical complications were observed, including 9 decementations of the crown, 6 screw loosenings, and 5 ceramic fractures. Periimplant mucositis was diagnosed in 36 patients (44.4%) and periimplantitis in 6 patients (7.4%). Correlation analysis showed a significant effect of the extent of periodontal bone loss of the remaining teeth on the marginal bone-level changes around implants (r=0.548, P<.001). Compatible CAD-CAM TiAs provide a viable treatment option for PSITR. However, in light of relatively high screw-loosening and decementation rates, choosing appropriate cements and abutment manufacturers is essential to improve the clinical performance of this treatment option. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  15. Incidence and characteristics of acute referred orofacial pain caused by a posterior single tooth pulpitis in an Iranian population.

    Science.gov (United States)

    Hashemipour, Maryam Alsadat; Borna, Roya

    2014-02-01

    This study was designed to evaluate incidence and characteristics of acute referred orofacial pain caused by a posterior single tooth pulpitis in an Iranian population. In this cross-sectional study, 3,150 patients (1,400 males and 1,750 females) with pain in the orofacial region were evaluated via clinical and radiographic examination to determine their pain source. Patients completed a standardized clinical questionnaire consisting of a numerical rating scale for pain intensity and chose verbal descriptors from short form McGill questionnaire to describe the quality of their pain. Visual analog scale (VAS) was used to score pain intensity. In addition, patients indicated sites to which pain referred by drawing on an illustration of the head and neck. Data were analyzed using chi-square, fisher exact, and Mann-Whitney tests. Two thousand and hundred twenty patients (67/3%) reported pain in sites that diagnostically differed from the pain source. According to statistical analysis, sex (P = 0.02), intensity of pain (0.04), and quality (P = 0.001) of pain influenced its referral nature, while age of patients and kind of stimulus had no considerable effect on pain referral (P > 0.05). The results of the present study show the prevalence of referred pain in the head, face, and neck region is moderately high. Therefore, in patients with orofacial pain, it is essential to carefully examination before carrying out treatment that could be inappropriate. © 2013 The Authors Pain Practice © 2013 World Institute of Pain.

  16. Resonant Rayleigh light scattering of single Au nanoparticles with different sizes and shapes.

    Science.gov (United States)

    Truong, Phuoc Long; Ma, Xingyi; Sim, Sang Jun

    2014-02-21

    Scientific interest in nanotechnology is driven by the unique and novel properties of nanometer-sized metallic materials such as the strong interaction between the conductive electrons of the nanoparticles and the incident light, caused by localized surface plasmon resonances (LSPRs). In this article, we analysed the relationship of the Rayleigh scattering properties of a single Au nanoparticle with its size, shape, and local dielectric environment. We also provided a detailed study on the refractive index sensitivity of three types of differently shaped Au nanoparticles, which were nanospheres, oval-shaped nanoparticles and nanorods. This study helps one to differentiate the Rayleigh light scattering from individual nanoparticles of different sizes and/or shapes and precisely obtain quantitative data as well as the correlated optical spectra of single gold nanoparticles from the inherently inhomogeneous solution of nanoparticles. These results suggest that the shape, size and aspect ratio of Au nanoparticles are important structural factors in determining the resonant Rayleigh light scattering properties of a single Au nanoparticle such as its spectral peak position, scattering-cross-section and refractive index sensitivity, which gives a handle for the choice of gold nanoparticles for the design and fabrication of single nanosensors.

  17. DNA origami-based shape IDs for single-molecule nanomechanical genotyping

    Science.gov (United States)

    Zhang, Honglu; Chao, Jie; Pan, Dun; Liu, Huajie; Qiang, Yu; Liu, Ke; Cui, Chengjun; Chen, Jianhua; Huang, Qing; Hu, Jun; Wang, Lianhui; Huang, Wei; Shi, Yongyong; Fan, Chunhai

    2017-04-01

    Variations on DNA sequences profoundly affect how we develop diseases and respond to pathogens and drugs. Atomic force microscopy (AFM) provides a nanomechanical imaging approach for genetic analysis with nanometre resolution. However, unlike fluorescence imaging that has wavelength-specific fluorophores, the lack of shape-specific labels largely hampers widespread applications of AFM imaging. Here we report the development of a set of differentially shaped, highly hybridizable self-assembled DNA origami nanostructures serving as shape IDs for magnified nanomechanical imaging of single-nucleotide polymorphisms. Using these origami shape IDs, we directly genotype single molecules of human genomic DNA with an ultrahigh resolution of ~10 nm and the multiplexing ability. Further, we determine three types of disease-associated, long-range haplotypes in samples from the Han Chinese population. Single-molecule analysis allows robust haplotyping even for samples with low labelling efficiency. We expect this generic shape ID-based nanomechanical approach to hold great potential in genetic analysis at the single-molecule level.

  18. A 1-year randomised controlled trial comparing zirconia versus metal-ceramic implant supported single-tooth restorations.

    Science.gov (United States)

    Hosseini, Mandana; Worsaae, Nils; Schiodt, Morten; Gotfredsen, Klaus

    2011-01-01

    To compare the biological, technical and aesthetic outcomes of single implant-supported all-ceramic versus metal-ceramic crowns. Thirty-six patients with premolar agenesis were randomly treated with 38 all-ceramic (AC) and 37 metal-ceramic (MC) implant-supported single-tooth restorations. A quasi-randomisation of consecutively included restorations in patients with one or more implants was used, i.e. a combination of parallel group (for 13 patients with one restoration) and split-mouth (for 23 patients with ≥2 restorations). All patients were recalled for baseline and 1-year followup examinations. Biological and technical outcomes, including complications, were clinically and radiographically registered. The Copenhagen Index Score and visual analogue scale (VAS) score were used to assess professional and patient-reported aesthetic outcomes, respectively, by blinded assessors. One-year after loading, no patient dropped out and no implant failed, though one MC restoration had to be remade. The marginal bone loss was not significantly different between AC and MC restorations (AC: mean 0.08 mm, SD 0.25; MC: mean 0.10 mm, SD 0.17). Seven out of 10 inflammatory reactions were registered at AC restorations. Two technical complications, one loss of retention and one chipping of veneering porcelain were recorded at two metal-ceramic crowns. The marginal adaptation of the all-ceramic crowns was significantly less optimal than the metal-ceramic crowns (P = 0.014). The professional-reported colour match of all-ceramic crowns was significantly better than metal-ceramic crowns (P = 0.031), but other aesthetic parameters as well as the VAS scores demonstrated no statistically significant difference between AC and MC restorations. Marginal bone loss and the aesthetic outcomes were not significantly different between AC and MC restorations in this short-term follow-up study, though inflammatory reactions in the peri-implant mucosa as well as less optimal marginal adaptation were

  19. Strain sensor based on gourd-shaped single-mode-multimode-single-mode hybrid optical fibre structure.

    Science.gov (United States)

    Tian, Ke; Farrell, Gerald; Wang, Xianfan; Yang, Wenlei; Xin, Yifan; Liang, Haidong; Lewis, Elfed; Wang, Pengfei

    2017-08-07

    A fibre-optic strain sensor based on a gourd-shaped joint multimode fibre (MMF) sandwiched between two single-mode fibres (SMFs) is described both theoretically and experimentally. The cladding layers of the two MMFs are reshaped to form a hemisphere using an electrical arc method and spliced together, yielding the required gourd shape. The gourd-shaped section forms a Fabry-Perot cavity between the ends of two adjacent but non-contacting multimode fibres' core. The effectiveness of the multimode interference based on the Fabry-Perot interferometer (FPI) formed within the multimode inter-fibre section is greatly improved resulting in an experimentally determined strain sensitivity of -2.60 pm/με over the range 0-1000 με. The sensing characteristics for temperature and humidity of this optical fibre strain sensor are also investigated.

  20. Immediate Loading of Anterior Single-Tooth Implants Placed in Healed Sites: Five-Year Results of a Randomized Clinical Trial.

    Science.gov (United States)

    den Hartog, Laurens; Raghoebar, Gerry M; Stellingsma, Kees; Vissink, Arjan; Meijer, Henny Ja

    The aim of this study was to compare the 5-year outcome of immediate loading with that of conventional loading for anterior single-tooth implants placed in healed sites. It was hypothesized that immediate loading is not inferior to conventional loading. A total of 62 patients with a missing maxillary anterior tooth were included. At random, patients were treated with an implant that was restored either with a nonoccluding temporary crown within 24 hours after implant placement (immediate group) or according to a two-stage procedure after 3 months (conventional group). All implants were placed in healed sites. Follow-up visits were performed after definitive crown delivery and 1 and 5 years thereafter. Outcome measures were radiographic marginal bone level changes, implant survival, complications, soft tissue aspects (probing depth, plaque, bleeding, soft tissue level changes), esthetic outcome, and patient satisfaction. Three patients in each study group were lost to follow-up. No significant differences were found in terms of marginal bone loss (1.16 ± 0.93 mm in the immediate group and 1.20 ± 1.10 mm in the conventional group), survival (one implant lost in the immediate group), complications, soft tissue aspects, esthetic outcome, and patient satisfaction. For anterior single-tooth implants placed in healed sites, the outcome of immediate loading is not inferior to conventional loading.

  1. An Automatic Segmentation and Classification Framework Based on PCNN Model for Single Tooth in MicroCT Images.

    Directory of Open Access Journals (Sweden)

    Liansheng Wang

    Full Text Available Accurate segmentation and classification of different anatomical structures of teeth from medical images plays an essential role in many clinical applications. Usually, the anatomical structures of teeth are manually labelled by experienced clinical doctors, which is time consuming. However, automatic segmentation and classification is a challenging task because the anatomical structures and surroundings of the tooth in medical images are rather complex. Therefore, in this paper, we propose an effective framework which is designed to segment the tooth with a Selective Binary and Gaussian Filtering Regularized Level Set (GFRLS method improved by fully utilizing three dimensional (3D information, and classify the tooth by employing unsupervised learning Pulse Coupled Neural Networks (PCNN model. In order to evaluate the proposed method, the experiments are conducted on the different datasets of mandibular molars and the experimental results show that our method can achieve better accuracy and robustness compared to other four state of the art clustering methods.

  2. Shape-designed single-polymer micelles: a proof-of-concept simulation

    Science.gov (United States)

    Moths, Brian; Witten, Thomas A.

    Much effort has been directed towards self-assembling nanostructures. Strong, local interactions between specific building blocks often determine these structures (e.g., globular proteins). We seek to produce designed structures that are instead determined by collective effects of weak interactions (e.g., surfactant self-assembly). Such structures may reversibly change conformation or disassemble in response to changing solvent conditions, and, being soft, have potential to adapt to fluctuating or unknown application-imposed shape requirements. Concretely, we aim to realize such a structure in the form of a single polymer micelle--an amphiphilic polymer exhibiting a condensed, phase-segregated conformation when immersed in solvent. Connecting all amphiphiles into a single chain provides geometric constraints controlling the surface curvature profile, thus dictating a non-trivial shape. We present 2D Monte Carlo simulation results demonstrating the feasibility of such soft, shape-designed micelles. Preliminary results demonstrate a stable concave ``dimple'' in a micelle composed of a single A-B multiblock linear copolymer. We discuss both current limitations on shape robustness and effects of block asymmetry, block molecular weights and overall chain length on micelle shape. This work was supported in part by the National Science Foundation's MRSEC Program under Award Number DMR-1420709.

  3. An in vitro study to compare the accuracy of the master cast fabricated by four different transfer impression techniques for single-tooth implant replacement.

    Science.gov (United States)

    Lahori, Manesh; Nagrath, Rahul; Agrawal, Prateek

    2014-03-01

    Single tooth implant retained crowns have become a recognized technique for the replacement of the missing teeth. With the predictable integration of implants, the emphasis is shifted towards precise prosthesis. Minor movement of the impression coping retained inside the impression material can occur during all the procedures, leading to the three-dimensional spatial inaccuracies in the master casts. Therefore, the present study was undertaken with the purpose to evaluate the accuracy of single-tooth implant impression techniques using four different impression copings, so as to obtain a precise definitive cast for a single-unit implant restoration. A maxillary acrylic resin model with a standard single implant in the first molar region was used to simulate a clinical situation. A total of 60 impressions were made with polyvinylsiloxane impression material, which were divided into four groups of 15 impressions each. Group I used non-modified square impression coping, while in group II, III and IV square impression coping were modified differently. Master casts fabricated for all the groups were analyzed to detect rotational position change of the hexagon on the implant replicas in the master casts in reference to the resin model. The master casts obtained with the roughened and adhesive-coated impression copings showed a lower amount of rotational movement than the masters casts achieved with the non-modified impression copings. Hence, the clinician should use sandblasted and adhesive coated impression copings to achieve a more accurate and precise orientation of the implant replicas in the laboratory master casts in single-tooth implant restorations.

  4. Papilla height in relation to the distance between bone crest and interproximal contact point at single-tooth implants: A systematic review.

    Science.gov (United States)

    Roccuzzo, Mario; Roccuzzo, Andrea; Ramanuskaite, Ausra

    2018-03-01

    The aim of this systematic review was to investigate the tooth-implant papilla formation in correlation with the distance between the interproximal bone level and the prosthetic contact point. A comprehensive search of the current literature (01/01/2000-01/01/2017) was performed to identify human trials that included 10 patients or more, with at least 12 months follow-up, in need of the replacement of one single tooth in the anterior maxillary region with an implant-supported single crown. To meet the inclusion criteria, studies had to provide both radiographic and clinical data regarding the distance between the interproximal bone level and the prosthetic contact point. The search yielded 136 records. After evaluation of abstracts and full texts, 12 papers were included in the final review, even though various reference points, for the comparison between the vertical distance and the papilla height, were used. The vertical distance between the interproximal bone level and prosthetic contact point ranged between 2 and 11 mm, and the partial or complete papilla fill (Jemt's score 2-3) ranged between 56.5% and 100% of cases. There is limited evidence that the vertical distance from the base of the interproximal contact point to the crestal bone level seems to affect the interproximal papilla height; that is, the lower is the distance the higher is the percentage of papilla fill. Complete embrasure fill between an implant restoration and the adjacent tooth seems to be correlated with the integrity of the periodontal ligament of the tooth. To reduce the risk of aesthetic failures, interproximal probing on the adjacent teeth should be encouraged before implant placement. © 2018 The Authors. Clinical Oral Implants Research Published by John Wiley & Sons Ltd.

  5. Flux Concentration and Pole Shaping in a Single Phase Hybrid Switched Reluctance Motor Drive

    DEFF Research Database (Denmark)

    Jakobsen, Uffe; Lu, Kaiyuan

    2010-01-01

    The single phase hybrid switched reluctance motor (HSRM) may be a good candidate for low-cost drives used for pump applications. This paper presents a new design of the HSRM with improved starting torque achieved by stator pole shaping, and a better arrangement of the embedded stator permanent...

  6. [Study on the appropriate parameters of automatic full crown tooth preparation for dental tooth preparation robot].

    Science.gov (United States)

    Yuan, F S; Wang, Y; Zhang, Y P; Sun, Y C; Wang, D X; Lyu, P J

    2017-05-09

    of 11 resin teeth was approximately (2.089±0.026) mm, the error was about (0.089±0.026) mm; the average convergence angle was about 6.56°±0.30°, the error was about 0.56°±0.30°. Compared with the target preparation shape, the average shape error of the 11 resin tooth preparations was about 0.02-0.11 mm. And the average preparation depth of the occlusal surface of 15 natural teeth was approximately (2.097±0.022) mm, the error was about (0.097±0.022) mm; the average convergence angle was about 6.98°±0.35°, the error was about 0.98°±0.35°. Compared with the target preparation shape, the average shape error of the 15 natural tooth preparations was about 0.05-0.17 mm. Conclusions: The experimental results indicate that the automatic tooth preparation for resin teeth and the teeth were completed according to the specific parameters of the single cutting depth by the micro robot controlling picosecond laser respectively, its preparation accuracy met the clinical needs. And the suitability of the parameter was confirmed.

  7. Feasibility of immediate placement of single-tooth implants in the aesthetic zone : a1-year randomized controlled trial

    NARCIS (Netherlands)

    Slagter, Kirsten W.; Meijer, Henny J. A.; Bakker, Nicolaas A.; Vissink, Arjan; Raghoebar, Gerry M.

    AimTo assess whether outcome of immediate implant placement and immediate provisionalization after 1year was non-inferior to immediate implant placement and delayed provisionalization regarding Marginal Bone Level (MBL). Materials and MethodsForty patients with a failing tooth in the aesthetic zone

  8. Single-mode quantum cascade lasers employing a candy-cane shaped monolithic coupled cavity

    Science.gov (United States)

    Liu, Peter Q.; Sladek, Kamil; Wang, Xiaojun; Fan, Jen-Yu; Gmachl, Claire F.

    2011-12-01

    We demonstrate single-mode quantum cascade lasers emitting at ˜4.5 μm by employing a monolithic "candy-cane" shaped coupled-cavity consisting of a straight section connecting at one end to a spiral section. The fabrication process is identical to those for simple Fabry-Perot-type ridge lasers. Continuously tunable single-mode emission across ˜8 cm-1 with side mode suppression ratio up to ˜25 dB and a single-mode operating current range of more than 70% above the threshold current is achieved when the lasers are operated in pulsed-mode from 80 K to 155 K.

  9. Complex shapes self-assembled from single-stranded DNA tiles.

    Science.gov (United States)

    Wei, Bryan; Dai, Mingjie; Yin, Peng

    2012-05-30

    Programmed self-assembly of strands of nucleic acid has proved highly effective for creating a wide range of structures with desired shapes. A particularly successful implementation is DNA origami, in which a long scaffold strand is folded by hundreds of short auxiliary strands into a complex shape. Modular strategies are in principle simpler and more versatile and have been used to assemble DNA or RNA tiles into periodic and algorithmic two-dimensional lattices, extended ribbons and tubes, three-dimensional crystals, polyhedra and simple finite two-dimensional shapes. But creating finite yet complex shapes from a large number of uniquely addressable tiles remains challenging. Here we solve this problem with the simplest tile form, a 'single-stranded tile' (SST) that consists of a 42-base strand of DNA composed entirely of concatenated sticky ends and that binds to four local neighbours during self-assembly. Although ribbons and tubes with controlled circumferences have been created using the SST approach, we extend it to assemble complex two-dimensional shapes and tubes from hundreds (in some cases more than one thousand) distinct tiles. Our main design feature is a self-assembled rectangle that serves as a molecular canvas, with each of its constituent SST strands--folded into a 3 nm-by-7 nm tile and attached to four neighbouring tiles--acting as a pixel. A desired shape, drawn on the canvas, is then produced by one-pot annealing of all those strands that correspond to pixels covered by the target shape; the remaining strands are excluded. We implement the strategy with a master strand collection that corresponds to a 310-pixel canvas, and then use appropriate strand subsets to construct 107 distinct and complex two-dimensional shapes, thereby establishing SST assembly as a simple, modular and robust framework for constructing nanostructures with prescribed shapes from short synthetic DNA strands.

  10. Caterpillar locomotion-inspired valveless pneumatic micropump using a single teardrop-shaped elastomeric membrane

    KAUST Repository

    So, Hongyun

    2014-01-01

    This paper presents a microfluidic pump operated by an asymmetrically deformed membrane, which was inspired by caterpillar locomotion. Almost all mechanical micropumps consist of two major components of fluid halting and fluid pushing parts, whereas the proposed caterpillar locomotion-inspired micropump has only a single, bilaterally symmetric membrane-like teardrop shape. A teardrop-shaped elastomeric membrane was asymmetrically deformed and then consecutively touched down to the bottom of the chamber in response to pneumatic pressure, thus achieving fluid pushing. Consecutive touchdown motions of the teardrop-shaped membrane mimicked the propagation of a caterpillar\\'s hump during its locomotory gait. The initial touchdown motion of the teardrop-shaped membrane at the centroid worked as a valve that blocked the inlet channel, and then, the consecutive touchdown motions pushed fluid in the chamber toward the tail of the chamber connected to the outlet channel. The propagation of the touchdown motion of the teardrop-shaped membrane was investigated using computational analysis as well as experimental studies. This caterpillar locomotion-inspired micropump composed of only a single membrane can provide new opportunities for simple integration of microfluidic systems. © the Partner Organisations 2014.

  11. Cu-Al-Ni Shape Memory Single Crystal Wires with High Transformation Temperature

    Science.gov (United States)

    Hautcoeur, Alain; Fouché, Florian; Sicre, Jacques

    2016-01-01

    CN-250X is a new material with higher performance than Nickel-Titanium Shape Memory Alloy (SMA). For space mechanisms, the main disadvantage of Nickel-Titanium Shape Memory Alloy is the limited transformation temperature. The new CN-250X Nimesis alloy is a Cu-Al-Ni single crystal wire available in large quantity because of a new industrial process. The triggering of actuators made with this Cu-Al-Ni single crystal wire can range from ambient temperature to 200 C in cycling and even to 250 C in one-shot mode. Another advantage of CN-250X is a better shape recovery (8 to 10%) than Ni-Ti (6 to 7%). Nimesis is the first company able to produce this type of material with its new special industrial process. A characterization study is presented in this work, including the two main solicitation modes for this material: tensile and torsion. Different tests measure the shape recovery of Cu-Al-Ni single crystals wires during heating from room temperature to a temperature higher than temperature of end of martensitic transformation.

  12. Effects of single particle on shape phase transitions and phase coexistence in odd-even nuclei

    Science.gov (United States)

    Yu, Xiang-Ru; Hu, Jing; Li, Xiao-Xue; An, Si-Yu; Zhang, Yu

    2018-02-01

    A classical analysis of shape phase transitions and phase coexistence in odd-even nuclei has been performed in the framework of the interacting boson-fermion model. The results indicate that the effects of a single particle may influence different types of transitions in different ways. Especially, it is revealed that phase coexistence can clearly emerge in the critical region and thus be taken as a indicator of the shape phase transitions in odd-even nuclei. Supported by National Natural Science Foundation of China (11375005)

  13. Dynamical implications of sample shape for avalanches in 2-dimensional random-field Ising model with saw-tooth domain wall

    Science.gov (United States)

    Tadić, Bosiljka

    2018-03-01

    We study dynamics of a built-in domain wall (DW) in 2-dimensional disordered ferromagnets with different sample shapes using random-field Ising model on a square lattice rotated by 45 degrees. The saw-tooth DW of the length Lx is created along one side and swept through the sample by slow ramping of the external field until the complete magnetisation reversal and the wall annihilation at the open top boundary at a distance Ly. By fixing the number of spins N =Lx ×Ly = 106 and the random-field distribution at a value above the critical disorder, we vary the ratio of the DW length to the annihilation distance in the range Lx /Ly ∈ [ 1 / 16 , 16 ] . The periodic boundary conditions are applied in the y-direction so that these ratios comprise different samples, i.e., surfaces of cylinders with the changing perimeter Lx and height Ly. We analyse the avalanches of the DW slips between following field updates, and the multifractal structure of the magnetisation fluctuation time series. Our main findings are that the domain-wall lengths materialised in different sample shapes have an impact on the dynamics at all scales. Moreover, the domain-wall motion at the beginning of the hysteresis loop (HLB) probes the disorder effects resulting in the fluctuations that are significantly different from the large avalanches in the central part of the loop (HLC), where the strong fields dominate. Specifically, the fluctuations in HLB exhibit a wide multi-fractal spectrum, which shifts towards higher values of the exponents when the DW length is reduced. The distributions of the avalanches in this segments of the loops obey power-law decay and the exponential cutoffs with the exponents firmly in the mean-field universality class for long DW. In contrast, the avalanches in the HLC obey Tsallis density distribution with the power-law tails which indicate the new categories of the scale invariant behaviour for different ratios Lx /Ly. The large fluctuations in the HLC, on the other

  14. Method for developing an optimal emergence profile using heat-polymerized provisional restorations for single-tooth implant-supported restorations.

    Science.gov (United States)

    Macintosh, Daniel C T; Sutherland, Mark

    2004-03-01

    This article describes a method for creating an improved emergence profile with single-tooth, implant-supported restorations. An easily trimmed silicone gingival substitute is used to allow polymerization of acrylic resin provisional restorations to achieve control of the emergence profile. Gingival trauma is minimized by eliminating intraoral use of monomer and minimizing surgical procedures. Provisional restorations can be assessed to ensure the contour is acceptable and the trimmed gingival substitute can be used to fabricate a similar profile in the definitive prosthesis. The provisional restorations may be used instead of standard prefabricated healing abutments to guide the healing contours of the peri-implant gingival tissue.

  15. Detecting the shape of anisotropic gold nanoparticles in dispersion with single particle extinction and scattering.

    Science.gov (United States)

    Potenza, M A C; Krpetić, Ž; Sanvito, T; Cai, Q; Monopoli, M; de Araújo, J M; Cella, C; Boselli, L; Castagnola, V; Milani, P; Dawson, K A

    2017-02-23

    The shape and size of nanoparticles are important parameters affecting their biodistribution, bioactivity, and toxicity. The high-throughput characterisation of the nanoparticle shape in dispersion is a fundamental prerequisite for realistic in vitro and in vivo evaluation, however, with routinely available bench-top optical characterisation techniques, it remains a challenging task. Herein, we demonstrate the efficacy of a single particle extinction and scattering (SPES) technique for the in situ detection of the shape of nanoparticles in dispersion, applied to a small library of anisotropic gold particles, with a potential development for in-line detection. The use of SPES paves the way to the routine quantitative analysis of nanoparticles dispersed in biologically relevant fluids, which is of importance for the nanosafety assessment and any in vitro and in vivo administration of nanomaterials.

  16. Engineering single-polymer micelle shape using nonuniform spontaneous surface curvature

    Science.gov (United States)

    Moths, Brian; Witten, T. A.

    2018-03-01

    Conventional micelles, composed of simple amphiphiles, exhibit only a few standard morphologies, each characterized by its mean surface curvature set by the amphiphiles. Here we demonstrate a rational design scheme to construct micelles of more general shape from polymeric amphiphiles. We replace the many amphiphiles of a conventional micelle by a single flexible, linear, block copolymer chain containing two incompatible species arranged in multiple alternating segments. With suitable segment lengths, the chain exhibits a condensed spherical configuration in solution, similar to conventional micelles. Our design scheme posits that further shapes are attained by altering the segment lengths. As a first study of the power of this scheme, we demonstrate the capacity to produce long-lived micelles of horseshoe form using conventional bead-spring simulations in two dimensions. Modest changes in the segment lengths produce smooth changes in the micelle's shape and stability.

  17. Single-Tooth Morse Taper Connection Implant Placed in Grafted Site of the Anterior Maxilla: Clinical and Radiographic Evaluation

    Directory of Open Access Journals (Sweden)

    Francesco Guido Mangano

    2014-01-01

    Full Text Available The aim of this study was to achieve aesthetically pleasing soft tissue contours in a severely compromised tooth in the anterior region of the maxilla. For a right-maxillary central incisor with localized advanced chronic periodontitis a tooth extraction followed by reconstructive procedures and delayed implant placement was proposed and accepted by the patient. Guided bone regeneration (GBR technique was employed, with a biphasic calcium-phosphate (BCP block graft placed in the extraction socket in conjunction with granules of the same material and a resorbable barrier membrane. After 6 months of healing, an implant was installed. The acrylic provisional restoration remained in situ for 3 months and then was substituted with the definitive crown. This ridge reconstruction technique enabled preserving both hard and soft tissues and counteracting vertical and horizontal bone resorption after tooth extraction and allowed for an ideal three-dimensional implant placement. Localized severe alveolar bone resorption of the anterior maxilla associated with chronic periodontal disease can be successfully treated by means of ridge reconstruction with GBR and delayed implant insertion; the placement of an early-loaded, Morse taper connection implant in the grafted site was effective to create an excellent clinical aesthetic result and to maintain it along time.

  18. Strong field line shapes and photon statistics from a single molecule under anomalous noise.

    Science.gov (United States)

    Sanda, Frantisek

    2009-10-01

    We revisit the line-shape theory of a single molecule with anomalous stochastic spectral diffusion. Waiting time profiles for bath induced spectral jumps in the ground and excited states become different when a molecule, probed by continuous-wave laser field, reaches the steady state. This effect is studied for the stationary dichotomic continuous-time-random-walk spectral diffusion of a single two-level chromophore with power-law distributions of waiting times. Correlated waiting time distributions, line shapes, two-point fluorescence correlation function, and Mandel Q parameter are calculated for arbitrary magnitude of laser field. We extended previous weak field results and examined the breakdown of the central limit theorem in photon statistics, indicated by asymptotic power-law growth of Mandel Q parameter. Frequency profile of the Mandel Q parameter identifies the peaks of spectrum, which are related to anomalous spectral diffusion dynamics.

  19. Shaping Single Offset Reflector Antennas Using Local Axis-Displaced Confocal Quadrics

    Directory of Open Access Journals (Sweden)

    Rafael A. Penchel

    2016-01-01

    Full Text Available This work investigates a novel numerical procedure for the solution of an exact formulation for the Geometrical Optics synthesis of a single reflector antenna by simultaneously imposing Snell’s Law and Conservation of Energy in a tube of rays, yielding a second-order nonlinear partial differential equation of Monge-Ampère type, which can be solved as a boundary value problem. The investigation explores the interpolating properties of confocal quadrics to locally represent the shaped reflector surface. It allows the partial derivatives involved in the formulation to be analytically expressed. To illustrate the method, two examples of offset single reflectors shaped to radiate a Gaussian power density within a superelliptical contoured beam are presented. The results are validated by Physical Optics analysis with equivalent edge currents.

  20. Simultaneous SU(2) rotations on multiple quantum dot exciton qubits using a single shaped pulse

    Science.gov (United States)

    Mathew, Reuble; Yang, Hong Yi Shi; Hall, Kimberley C.

    2015-10-01

    Recent experimental demonstration of a parallel (π ,2 π ) single qubit rotation on excitons in two distant quantum dots [Nano Lett. 13, 4666 (2013), 10.1021/nl4018176] is extended in numerical simulations to the design of pulses for more general quantum state control, demonstrating the feasibility of full SU(2) rotations of each exciton qubit. Our results show that simultaneous high-fidelity quantum control is achievable within the experimentally accessible parameter space for commercial Fourier-domain pulse shaping systems. The identification of a threshold of distinguishability for the two quantum dots (QDs) for achieving high-fidelity parallel rotations, corresponding to a difference in transition energies of ˜0.25 meV , points to the possibility of controlling more than 10 QDs with a single shaped optical pulse.

  1. Destruction and Accompanying Phenomena in a Ferromagnetic Ni2MnGa Single Crystal with a Shape-Memory Effect

    Science.gov (United States)

    Ostrikov, O. M.; Shmatok, E. V.

    2015-01-01

    Features of the shape of a macroscopic interplanar crack have been studied, and phenomena accompanying destruction in a monocrystalline ferromagnetic Ni2MnGa alloy with shape memory have been analyzed. It has been established that the initiation of destruction in Ni2MnGa is actively influenced by the processes of slip and interaction of twin boundaries in twin planes which are at small angles to each other, and also by the formation of Rose channels. On the source side of the surface at which the crack has nucleated, it is tooth-shaped. On this surface, there are signs of rotation of the crystal lattice from twins with boundaries parallel and perpendicular to the crack's edges. The opening of the crack in its boundary regions leads to partial untwining.

  2. Immediate, Non Submerged Root Analog Zirconia Implant in Single Rooted Tooth Replacement: Case Report with 2 years Follow Up.

    Science.gov (United States)

    Patankar, Amod; Kshirsagar, Rajesh; Patankar, Swapna; Pawar, Sudhir

    2016-07-01

    This report demonstrates the clinical use of a modified, truly anatomic, root analogue zirconia implant for immediate replacement of a right mandibular first premolar. A 22-year-old female patient with chronic apical periodontitis of the right mandibular first premolar was referred and the tooth was carefully extracted. A truly anatomical, root identical, roughened zirconia implant modified by macro-retentions was manufactured and placed into the extraction socket by tapping 3 days later. After 4 months a composite crown was cemented in place. No complications occurred during the healing period. A good functional and aesthetic result was achieved with minimal bone resorption and soft tissue recession at 18 months follow-up. This report describes the successful clinical use of an immediate, single stage, truly anatomical root-analogue zirconia implant for replacement of a single rooted tooth. Significant modifications such as macro-retentions yielded primary stability and excellent osseointegration. This novel approach is minimally invasive, respects the underlying anatomy and aids socket prevention. In addition the procedure saves time and cost, has good patient acceptance as there is no need for osteotomy, sinus lift or bone augmentation.

  3. Esthetics of Flapless Single-Tooth Implants in the Anterior Maxilla Using Guided Surgery: Association of Three-Dimensional Accuracy and Pink Esthetic Score.

    Science.gov (United States)

    Fürhauser, Rudolf; Mailath-Pokorny, Georg; Haas, Robert; Busenlechner, Dieter; Watzek, Georg; Pommer, Bernhard

    2015-10-01

    Flapless implant placement using surgical templates may guarantee predictable and esthetic results provided that preplanned implant positions are transfered precisely into surgical reality. The study aims to investigate the effect of three-dimensional accuracy in guided implant surgery on the esthetic outcome of single-tooth implants in the anterior maxilla. Single-tooth implants for delayed replacement of upper incisors were inserted in 27 patients using stereolithographic templates. Superimposition of postoperative cone beam computed tomography (CBCT) scans allowed assessment of positional inaccuracy at the implant shoulder and apex, as well as angular deviation. Objective evaluation of implant esthetics was performed after a mean follow-up of 2.3 years using the Pink Esthetic Score (PES). Mean deviation between planned and actual implant position was 0.84 mm at the implant shoulder and significantly correlated to average PES of 12 (p = .031). Inaccuracy toward the buccal side was most frequent (70%). Deviations  ≥  0.8  mm resulted in significantly worse implant esthetics (median PES: 9.5, interquartile range [IQR]: 8-11) compared with more accurate implant positions (median PES: 13, IQR: 12-13, p = .039). Positional inaccuracy is low in guided implant surgery, but may however significantly compromise implant esthetics in the anterior maxilla. © 2014 Wiley Periodicals, Inc.

  4. Debris Evaluation after Root Canal Shaping with Rotating and Reciprocating Single-File Systems

    Directory of Open Access Journals (Sweden)

    Alberto Dagna

    2016-10-01

    Full Text Available This study evaluated the root canal dentine surface by scanning electron microscope (SEM after shaping with two reciprocating single-file NiTi systems and two rotating single-file NiTi systems, in order to verify the presence/absence of the smear layer and the presence/absence of open tubules along the walls of each sample; Forty-eight single-rooted teeth were divided into four groups and shaped with OneShape (OS, F6 SkyTaper (F6, WaveOne (WO and Reciproc and irrigated using 5.25% NaOCl and 17% EDTA. Root canal walls were analyzed by SEM at a standard magnification of 2500×. The presence/absence of the smear layer and the presence/absence of open tubules at the coronal, middle, and apical third of each canal were estimated using a five-step scale for scores. Numeric data were analyzed using Kruskal-Wallis and Mann-Whitney U statistical tests and significance was predetermined at P < 0.05; The Kruskal-Wallis ANOVA for debris score showed significant differences among the NiTi systems (P < 0.05. The Mann-Whitney test confirmed that reciprocating systems presented significantly higher score values than rotating files. The same results were assessed considering the smear layer scores. ANOVA confirmed that the apical third of the canal maintained a higher quantity of debris and smear layer after preparation of all the samples; Single-use NiTi systems used in continuous rotation appeared to be more effective than reciprocating instruments in leaving clean walls. The reciprocating systems produced more debris and smear layer than rotating instruments.

  5. Temperature dependent evolution of wrinkled single-crystal silicon ribbons on shape memory polymers.

    Science.gov (United States)

    Wang, Yu; Yu, Kai; Qi, H Jerry; Xiao, Jianliang

    2017-10-25

    Shape memory polymers (SMPs) can remember two or more distinct shapes, and thus can have a lot of potential applications. This paper presents combined experimental and theoretical studies on the wrinkling of single-crystal Si ribbons on SMPs and the temperature dependent evolution. Using the shape memory effect of heat responsive SMPs, this study provides a method to build wavy forms of single-crystal silicon thin films on top of SMP substrates. Silicon ribbons obtained from a Si-on-insulator (SOI) wafer are released and transferred onto the surface of programmed SMPs. Then such bilayer systems are recovered at different temperatures, yielding well-defined, wavy profiles of Si ribbons. The wavy profiles are shown to evolve with time, and the evolution behavior strongly depends on the recovery temperature. At relatively low recovery temperatures, both wrinkle wavelength and amplitude increase with time as evolution progresses. Finite element analysis (FEA) accounting for the thermomechanical behavior of SMPs is conducted to study the wrinkling of Si ribbons on SMPs, which shows good agreement with experiment. Merging of wrinkles is observed in FEA, which could explain the increase of wrinkle wavelength observed in the experiment. This study can have important implications for smart stretchable electronics, wrinkling mechanics, stimuli-responsive surface engineering, and advanced manufacturing.

  6. Shape dependent synthesis and field emission induced rectification in single ZnS nanocrystals.

    Science.gov (United States)

    Thupakula, Umamahesh; Dalui, Amit; Debangshi, Anupam; Bal, Jayanta K; Kumar, Gundam S; Acharya, Somobrata

    2014-05-28

    We report on the synthesis of shape controlled ZnS nanocrystals designed into nanodots, nanorods, and nanowires retaining the same diameter and crystallographic phase. We used UHV scanning tunneling microscopy and spectroscopy to study rectification behavior from single nanocrystals. The nanorod and nanowire show large tunneling current at the negative bias in comparison to the positive bias demonstrating current rectification, while the nanodot shows symmetric current-voltage behavior. We proposed a tunneling mechanism where direct tunneling is followed by resonant tunneling mechanism through ZnS nanocrystal at lower applied bias voltages. Stimulation of field emission in Fowler-Nordheim tunneling regime at higher negative bias voltages enables the rectification behavior from the ZnS nanorod or nanowire. Absence of rectification from the ZnS nanodot is associated with spherical shape where the field emission becomes less significant. Realizing functional electronic component from such shape dependent single ZnS nanocrystal may provide a means in realizing nanocrystal based miniaturized devices.

  7. Processing of complex shapes with single-mode resonant frequency microwave applicators

    International Nuclear Information System (INIS)

    Fellows, L.A.; Delgado, R.; Hawley, M.C.

    1994-01-01

    Microwave processing is an alternative to conventional composite processing techniques. Single-mode microwave applicators efficiently couple microwave energy into the composite. The application of the microwave energy is greatly affected by the geometry of the composite. In the single mode microwave applicator, two types of modes are available. These modes are best suited to processing flat planar samples or cylindrical samples with geometries that align with the electric fields. Mode-switching is alternating between different electromagnetic modes with the intelligent selection of the modes to alleviate undesirable temperature profiles. This method has improved the microwave heating profiles of materials with complex shapes that do not align with either type of electric field. Parts with two different complex geometries were fabricated from a vinyl toluene/vinyl ester resin with a continuous glass fiber reinforcement by autoclaving and by microwave techniques. The flexural properties of the microwave processed samples were compared to the flexural properties of autoclaved samples. The trends of the mechanical properties for the complex shapes were consistent with the results of experiments with flat panels. This demonstrated that mode-switching techniques are as applicable for the complex shapes as they are for the simpler flat panel geometry

  8. Control of single-photon routing in a T-shaped waveguide by another atom

    Science.gov (United States)

    Huang, Jin-Song; Wang, Jing-Wen; Wang, Yan; Li, Yan-Ling; Huang, You-Wen

    2018-04-01

    Quantum routers with a high routing rate of much more than 0.5 are of great importance for quantum networks. We provide a scheme to perform bidirectional high routing-rate transfer in a T-shaped coupled-resonator waveguide (CRW), which extends a recent unidirectional scheme proposed by Lu et al. (Opt Express 23:22955, 2015). By locating an extra two-level atom in the infinite CRW channel of the T-shaped CRW with a three-level system, an effective potential is generated. Our numerical results show that high routing capability from the infinite CRW channel to the semi-infinite channel can be achieved, and routing capability from the semi-infinite CRW channel to the infinite channel can also be significantly enhanced, with the help of the effective potential. Therefore, the proposed double-atom configuration could be utilized as a bidirectional quantum routing controller to implement high transfer rate routing of single photons.

  9. Intentional replantation of periodontally compromised hopeless tooth

    OpenAIRE

    Nagappa, G.; Aspalli, Shivanand; Devanoorkar, Archana; Shetty, Sudhir; Parab, Prachi

    2013-01-01

    Aesthetic considerations have influenced the management of dental maladies in varying degrees for many years. Even single tooth mal-alignment makes the patient to approach a dentist. Intentional replantation is a procedure in which an intentional tooth extraction is performed followed by reinsertion of the extracted tooth. Many authors agree that it should be reserved as the last resort to save a tooth after other procedures have failed or would likely to fail. The main reason of failure in r...

  10. Peri-implant tissue response following connective tissue and bone grafting in conjunction with immediate single-tooth replacement in the esthetic zone: a case series.

    Science.gov (United States)

    Tsuda, Hirotaka; Rungcharassaeng, Kitichai; Kan, Joseph Y K; Roe, Phillip; Lozada, Jaime L; Zimmerman, Grenith

    2011-01-01

    This case series evaluated the peri-implant tissue response following extraction and immediate placement and restoration of an implant in conjunction with subepithelial connective tissue grafting (SCTG) and bone grafting in the esthetic zone. Implant success rates and the peri-implant tissue response were also reported. Ten patients (four men, six women) with a mean age of 48 years (range, 35 to 70) underwent extraction and immediate tooth replacement with SCTG and were evaluated clinically and radiographically presurgically (T0), immediately after immediate tooth replacement and SCTG (T1), and at 3 months (T2), 6 months (T3), and 12 months (T4) after surgery. Data was analyzed using Friedman and Wilcoxon signed-ranks tests at the significance level of a = .05. At 1 year, all implants remained osseointegrated, with an overall mean marginal bone change of +0.10 mm and a mean facial gingival level change of -0.05 mm. Modified Plaque Index scores showed that patients were able to maintain a good level of hygiene throughout the study. Papilla Index scores indicated that at T4, more than 50% papilla fill was observed in 80% of all sites. The results of this case series suggest that, in addition to a favorable implant success rate and peri-implant tissue response, the facial gingival level around single immediately placed implants can also be maintained following connective tissue grafting when proper three-dimensional implant positioning is achieved and bone is grafted into the implant-socket gap.

  11. Natural Tooth Pontic: An Instant Esthetic Option for Periodontally Compromised Teeth—A Case Series

    Directory of Open Access Journals (Sweden)

    Rishi Raj

    2016-01-01

    Full Text Available Sudden tooth loss in the esthetic zone of the maxillary or mandibular anterior region can be due to trauma, periodontal disease, or endodontic failure. The treatment options for replacing the missing tooth can vary between removable prosthesis, tooth-supported prosthesis, and implant-supported prosthesis. Irrespective of the final treatment, the first line of management would be to provisionally restore the patient’s esthetic appearance at the earliest, while functionally stabilizing the compromised arch. Using the patient’s own natural tooth as a pontic offers the benefits of being the right size, shape, and color and provides exact repositioning in its original intraoral three-dimensional position. Additionally, using the patient’s platelet concentrate (platelet rich fibrin facilitates early wound healing and preservation of alveolar ridge shape following tooth extraction. The abutment teeth can also be preserved with minimal or no preparation, thus keeping the technique reversible, and can be completed at the chair side thereby avoiding laboratory costs. This helps the patient better tolerate the effect of tooth loss psychologically. The article describes a successful, immediate, and viable technique for rehabilitation of three different patients requiring replacement of a single periodontally compromised tooth in an esthetic region.

  12. Evaluation of a one-piece ceramic implant used for single-tooth replacement and three-unit fixed partial dentures: a prospective cohort clinical trial.

    Science.gov (United States)

    Jung, Ronald E; Grohmann, Philipp; Sailer, Irena; Steinhart, Yann-Niclas; Fehér, Aurel; Hämmerle, Christoph; Strub, Jörg Rudolf; Kohal, Ralf

    2016-07-01

    The aim of this clinical trial was to evaluate the safety and efficiency of a one-piece zirconia oral implant after 1 year of function. Two centers included 60 subjects in need of implant-supported single-tooth restorations or three-unit bridges. A total of 71 zirconia one-piece implants were placed and immediately restored with a temporary reconstruction for at least 2 months. The final veneered zirconia restorations were then cemented and followed for 6 months and 1 year after insertion of the restorations. At each visit, a clinical evaluation was performed to analyze biological parameters of the implants and the neighboring teeth. A standardized periapical radiograph was taken at implant insertion, at the placement of the restorations and at the 1-year follow-up. Sixty patients with 71 implants (48 in the mandible, 23 in the maxilla) were included in this study and provided with 11 bridges and 49 crowns. Two patients with three implants (one bridge and one single crown) could not be evaluated. One patient lost his implant 5 weeks after implant insertion. Based on 58 patients, the mean survival rate was 98.3% after one year when the implants of the two patients that did not show up were not counted as lost. The mean marginal bone loss from implant insertion to the 1-year follow-up after the final prosthetic restoration was 0.78 mm with a standard deviation of 0.79 mm. The probing depth around the implants increased from 2.7 mm at insertion of the prosthetic reconstruction to 3.5 mm one year after insertion. The probing depth around the adjacent teeth remained stable at 2.5 mm. At the 1-year recall, the difference was significant. The clinical attachment levels at implants and teeth were not different at the 1-year follow-up with 3.1 mm at tooth and implant sites. The presently tested one-piece ceramic implant was successful in replacing single tooth and three-unit gaps after one year of function. Further long-term data are necessary to verify these

  13. Clinician assessments and patient perspectives of single-tooth implant restorations in the esthetic zone of the maxilla: A systematic review.

    Science.gov (United States)

    Arunyanak, Sirikarn P; Pollini, Adrien; Ntounis, Athanasios; Morton, Dean

    2017-07-01

    Esthetic outcomes associated with implant dentistry are important to both clinicians and patients. However, esthetic satisfaction may vary between the 2 groups. In order to evaluate the current publications relating to this topic, the following focused question was developed, "what are the quantitative and qualitative differences between clinician evaluations and patient perspectives in the assessment of single-tooth implant outcomes in the esthetic zone?" The purpose of this systematic review was to identify differences in esthetic satisfaction between clinicians and patients when evaluating single-tooth implant-supported restorations. An electronic search of the Medline database and Cochrane Central Register of Controlled Trials (2000 to 2014) was performed. The search was supplemented by a manual search of specific journals. A quality assessment of full-text articles was performed according to Cochrane Collaboration's tool and Newcastle-Ottawa scale for risk of bias assessment. Information regarding outcomes was collected and compared. The search term combinations identified 555 titles. Subsequent to further review, 11 publications, including 2 randomized controlled trials, were selected for inclusion. Because of the heterogeneity of the study designs, study interventions, and esthetic assessment methods, no meta-analysis was performed. The clinicians identified a satisfactory outcome in 51% to 100% for peri-implant soft tissue and 62% to 90% for implant restorations. Patients showed a mean range score of 43% to 93% for peri-implant soft tissue and 81% to 96% for implant restorations. The visual analog scale score of the dentists was always lower than that of the patients. The review identified correlations between subjective and objective assessments for the Pink Esthetic Score (PES), the Papilla Index (PI), the Implant Crown Aesthetic Index (ICAI), and the modified (mod-ICAI) indices. Clinicians are more critical of esthetic outcomes than patients. The PES and

  14. Soft and Hard Tissue Changes Following Immediate Placement or Immediate Restoration of Single-Tooth Implants in the Esthetic Zone: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Yan, Qi; Xiao, Li-Qun; Su, Mei-Ying; Mei, Yan; Shi, Bin

    This systematic review aimed to compare immediate protocols with conventional protocols of single-tooth implants in terms of changes in the surrounding hard and soft tissue in the esthetic area. Electronic and manual searches were performed in PubMed, EMBASE, Cochrane, and other data systems for research articles published between January 2001 and December 2014. Only randomized controlled trials (RCTs) reporting on hard and or soft tissue characteristics following a single-tooth implant were included. Based on the protocol used in each study, the included studies were categorized into three groups to assess the relationships between the factors and related esthetic indexes. Variables such as marginal bone level changes (mesial, distal, and mean bone level), peri-implant soft tissue changes (papilla level, midbuccal mucosa, and probing depth), and other esthetic indices were taken into consideration. The data were analyzed using RevMan version 5.3, Stata 12, and GRADEpro 3.6.1 software. A total of 13 RCTs met the inclusion criteria. Four studies examined immediate implant placement, five studies examined immediate implant restoration, and four studies examined immediate loading. Comparing the bone level changes following immediate and conventional restoration, no significant differences were found in the bone level of the mesial site (standard mean difference [SMD] = -0.04 mm; 95% confidence interval [CI]: -0.25 to 0.17 mm), the distal site (SMD = -0.15 mm; 95% CI: -0.38 to 0.09 mm), and the mean bone level changes (SMD = 0.05 mm; 95% CI: -0.18 to 0.27 mm). The difference in the marginal bone level changes between immediate and conventional loading was also not statistically significant (SMD = -0.05 mm; 95% CI: -0.15 to 0.06 mm for the mesial site and SMD = -0.02 mm; 95% CI: -0.09 to 0.05 mm for the distal site). Soft tissue changes following immediate and conventional restoration reported no significant differences in the papillae level of the mesial site (SMD = 0

  15. Real-time shape approximation and fingerprinting of single proteins using a nanopore

    Science.gov (United States)

    Yusko, Erik C.; Bruhn, Brandon R.; Eggenberger, Olivia M.; Houghtaling, Jared; Rollings, Ryan C.; Walsh, Nathan C.; Nandivada, Santoshi; Pindrus, Mariya; Hall, Adam R.; Sept, David; Li, Jiali; Kalonia, Devendra S.; Mayer, Michael

    2017-05-01

    Established methods for characterizing proteins typically require physical or chemical modification steps or cannot be used to examine individual molecules in solution. Ionic current measurements through electrolyte-filled nanopores can characterize single native proteins in an aqueous environment, but currently offer only limited capabilities. Here we show that the zeptolitre sensing volume of bilayer-coated solid-state nanopores can be used to determine the approximate shape, volume, charge, rotational diffusion coefficient and dipole moment of individual proteins. To do this, we developed a theory for the quantitative understanding of modulations in ionic current that arise from the rotational dynamics of single proteins as they move through the electric field inside the nanopore. The approach allows us to measure the five parameters simultaneously, and we show that they can be used to identify, characterize and quantify proteins and protein complexes with potential implications for structural biology, proteomics, biomarker detection and routine protein analysis.

  16. Optical trap for both transparent and absorbing particles in air using a single shaped laser beam.

    Science.gov (United States)

    Redding, Brandon; Pan, Yong-Le

    2015-06-15

    Optical trapping of airborne particles is emerging as an essential tool in applications ranging from online characterization of living cells and aerosols to particle transport and delivery. However, existing optical trapping techniques using a single laser beam can trap only transparent particles (via the radiative pressure force) or absorbing particles (via the photophoretic force), but not particles of either type-limiting the utility of trapping-enabled aerosol characterization techniques. Here, we present the first optical trapping technique capable of trapping both transparent and absorbing particles with arbitrary morphology using a single shaped laser beam. Such a general-purpose optical trapping mechanism could enable new applications such as trapping-enabled aerosol characterization with high specificity.

  17. Magnetization, shape memory and hysteresis behavior of single and polycrystalline FeNiCoTi

    International Nuclear Information System (INIS)

    Sehitoglu, H.; Efstathiou, C.; Maier, H.J.; Chumlyakov, Y.

    2005-01-01

    We report on the shape memory characteristics and magnetic behavior of polycrystalline and single crystalline FeNiCoTi. Predeforming the samples in the martensitic state and biasing of the martensite variants produced anisotropy in the magnetization behavior allowing the 'easy axis' to be identified as the 'a-axis' in the martensitic state. Based on these results, we provide an estimate of the magnetic anisotropy energy as 8.34x10 5 ergs/cm 3 . The results confirm the different magnetization behavior in the martensitic and austenitic states, and the shift in transformation temperatures upon application of a magnetic field. Shape memory strains near 2.5% are demonstrated under constant stress temperature cycling and upon heating at zero stress after deformation. We present a thermodynamics based theory that explains the origin of the hysteresis in this class of alloys emanating from the dissipation of energy due to plastic deformation. We predict the thermal hysteresis (135 K), and the shift in transformation temperature (14 K) with applied magnetic fields in agreement with the experimental results. The possibility of utilizing these classes of alloys as magnetic shape memory alloys is discussed

  18. Discriminating single-bacterial shape using low-aspect-ratio pores.

    Science.gov (United States)

    Tsutsui, Makusu; Yoshida, Takeshi; Yokota, Kazumichi; Yasaki, Hirotoshi; Yasui, Takao; Arima, Akihide; Tonomura, Wataru; Nagashima, Kazuki; Yanagida, Takeshi; Kaji, Noritada; Taniguchi, Masateru; Washio, Takashi; Baba, Yoshinobu; Kawai, Tomoji

    2017-12-12

    Conventional concepts of resistive pulse analysis is to discriminate particles in liquid by the difference in their size through comparing the amount of ionic current blockage. In sharp contrast, we herein report a proof-of-concept demonstration of the shape sensing capability of solid-state pore sensors by leveraging the synergy between nanopore technology and machine learning. We found ionic current spikes of similar patterns for two bacteria reflecting the closely resembled morphology and size in an ultra-low thickness-to-diameter aspect-ratio pore. We examined the feasibility of a machine learning strategy to pattern-analyse the sub-nanoampere corrugations in each ionic current waveform and identify characteristic electrical signatures signifying nanoscopic differences in the microbial shape, thereby demonstrating discrimination of single-bacterial cells with accuracy up to 90%. This data-analytics-driven microporescopy capability opens new applications of resistive pulse analyses for screening viruses and bacteria by their unique morphologies at a single-particle level.

  19. Self-assembly of complex two-dimensional shapes from single-stranded DNA tiles.

    Science.gov (United States)

    Wei, Bryan; Vhudzijena, Michelle K; Robaszewski, Joanna; Yin, Peng

    2015-05-08

    Current methods in DNA nano-architecture have successfully engineered a variety of 2D and 3D structures using principles of self-assembly. In this article, we describe detailed protocols on how to fabricate sophisticated 2D shapes through the self-assembly of uniquely addressable single-stranded DNA tiles which act as molecular pixels on a molecular canvas. Each single-stranded tile (SST) is a 42-nucleotide DNA strand composed of four concatenated modular domains which bind to four neighbors during self-assembly. The molecular canvas is a rectangle structure self-assembled from SSTs. A prescribed complex 2D shape is formed by selecting the constituent molecular pixels (SSTs) from a 310-pixel molecular canvas and then subjecting the corresponding strands to one-pot annealing. Due to the modular nature of the SST approach we demonstrate the scalability, versatility and robustness of this method. Compared with alternative methods, the SST method enables a wider selection of information polymers and sequences through the use of de novo designed and synthesized short DNA strands.

  20. Socket seal surgery: Clinical uses in implant dentistry and guided bone regeneration procedures for single tooth replacement in the esthetic zone.

    Science.gov (United States)

    Negri, Bruno; Zuhr, Otto; Fickl, Stefan; Ciurana, Xavier Rodríguez; Navarro Martínez, José Manuel; Blanco, Víctor Méndez

    2016-02-01

    Restoring failing anterior teeth with a dental implant is considered a complex treatment even with thorough biologic knowledge of the situation. The goal is to produce a result in which the labial soft tissues and the papillae remain stable over time. Treatment of the fresh extraction socket in the alveolar ridge presents a challenge in everyday clinical practice. Regardless of the subsequent treatment, maintenance of the ridge contour will frequently facilitate all further therapeutic steps. Socket seal surgery and socket preservation in combination with immediate, early, or delayed implant placement can be valuable procedures for single tooth replacement. However, their potential as ridge preservation techniques in these different situations still needs to be demonstrated. The use of these procedures is illustrated in three consecutive cases.

  1. One-piece internal zirconia abutments for single-tooth restorations on narrow and regular diameter implants: A 5-year prospective follow-up study.

    Science.gov (United States)

    Nilsson, Andrée; Johansson, Lars-Åke; Lindh, Christina; Ekfeldt, Anders

    2017-10-01

    Studies have reported an increased risk for fractures of zirconia abutments compared with titanium abutments. The aim of this study was to evaluate single-tooth implant restorations with one-piece yttria-stabilized internal zirconia abutments on narrow and regular diameter implants up to 6 years after insertion. This study comprises 52 consecutively treated patients, with a median age of 19 years. In total, 59 narrow (3.3 mm) and 10 regular (4.1 mm) diameter implants were installed. Sixty-five all-ceramic crowns were cemented on implant-supported one-piece internal zirconia abutments and 4 restorations were screw-retained. Thirty-five patients with 48 implant restorations participated in the final examination and another 14 patients with 16 implant restorations were possible to reach and could be interviewed. The implant survival was 100% but the survival rate for the implant-supported ceramic restorations was lower, 87.5%. Three crowns (4.7%) were remade for different reasons. Five restorations (7.8%) were remade due to fracture of the internal one-piece zirconia abutment. Four of these fractures occurred in 3.3 mm implant abutments. Narrow diameter implants offer an opportunity to restore small single-tooth edentulous gaps. For esthetical reasons the choice of an abutment in zirconia can be favorable, but at least with the used implant system, there seems to be an increased risk for fracture. Most patients were very satisfied with the esthetics and function of their implant restorations. © 2017 Wiley Periodicals, Inc.

  2. [Clinical observation on the characteristics of occlusion and tooth abrasion in patients with cracked tooth].

    Science.gov (United States)

    Chen, Yu; Lin, Zheng-mei; Ling, Jun-qi

    2009-09-01

    To investigate the occlusal characteristics and the condition of tooth abrasion in patients with cracked tooth and to discuss the etiology of the cracked tooth and the relationships between occlusal disorder, tooth abrasion and cracked tooth. Twenty-seven patients with cracked tooth were selected. The occlusal courses were recorded by T-ScanIII system in intercuspal position, protrusive movement and lateral movement. Teeth with cracked tooth were regarded as the cracked tooth group, and the healthy adjacent teeth as the control group. The distribution of premature contact, occlusal interference, the center of occlusal force were examined. The abrasive conditions of the two groups were recorded according to the Smith tooth wear index and compared. There were more teeth with occlusal interference in cracked tooth group (20 teeth) than in the control group (6 teeth), which was significantly different (OR = 5.67, chi(2) = 8.45, P = 0.003). In 24 patients with single affected tooth, the center of occlusal force (COF) located in the inside and outside ellipse were 6 teeth (25%) and 18 teeth (75%) respectively, Z test showed that there were statistical differences between the cracked tooth group and normal people. In cracked tooth group, the proportion of the teeth with abrasion was higher in teeth with occlusal interference than those without occlusal interference (chi(2) = 4.79, P = 0.029). The formation of the cracked tooth was related to the occlusal disorder and associated with the tooth abrasion.

  3. Evaluation of soft tissues around single tooth implants in the anterior maxilla restored with cemented and screw-retained crowns.

    Science.gov (United States)

    Cutrim, Emerson Souza; Peruzzo, Daiane Cristina; Benatti, Bruno

    2012-12-01

    Implant-supported restorations can be attached as screw-retained or cemented prostheses. In both situations, the characteristics of the soft tissues around the implants are crucial for oral rehabilitation and patient satisfaction. Therefore, this study uses the Pink Esthetic Score (PES), which allows evaluation of gingival esthetics around implants, to evaluate the soft tissues around implants in the anterior maxilla rehabilitated with cemented prostheses (CP) and screw-retained prostheses (SP). Forty implants placed in the anterior maxilla were evaluated, and these had been rehabilitated with prosthetic crowns for a minimum of 1 year. Periodontal examination was performed to evaluate probing depth (PD) and bleeding on probing (BOP) of the implant and the corresponding natural tooth. The total mean (±SD) PES for SP was 10.73 (±1.98) and 10.41 (±2.67) for CP, which was not statistically significant (P ≥ .05). Periodontal examination revealed that CP and SP showed no difference for BOP (P ≥ .05). Differences were only detected in PD when comparing the reference teeth of both groups to CP and SP (P ≤ .05). The present study demonstrates that the PES proved to be an efficient index to assess peri-implant tissues, and that the type of crown retention does not influence the health and quality of the soft tissues around implants.

  4. Finite Element Analysis of a Copper Single Crystal Shape Memory Alloy-Based Endodontic Instruments

    Science.gov (United States)

    Vincent, Marin; Thiebaud, Frédéric; Bel Haj Khalifa, Saifeddine; Engels-Deutsch, Marc; Ben Zineb, Tarak

    2015-10-01

    The aim of the present paper is the development of endodontic Cu-based single crystal Shape Memory Alloy (SMA) instruments in order to eliminate the antimicrobial and mechanical deficiencies observed with the conventional Nickel-Titane (NiTi) SMA files. A thermomechanical constitutive law, already developed and implemented in a finite element code by our research group, is adopted for the simulation of the single crystal SMA behavior. The corresponding material parameters were identified starting from experimental results for a tensile test at room temperature. A computer-aided design geometry has been achieved and considered for a finite element structural analysis of the endodontic Cu-based single crystal SMA files. They are meshed with tetrahedral continuum elements to improve the computation time and the accuracy of results. The geometric parameters tested in this study are the length of the active blade, the rod length, the pitch, the taper, the tip diameter, and the rod diameter. For each set of adopted parameters, a finite element model is built and tested in a combined bending-torsion loading in accordance with ISO 3630-1 norm. The numerical analysis based on finite element procedure allowed purposing an optimal geometry suitable for Cu-based single crystal SMA endodontic files. The same analysis was carried out for the classical NiTi SMA files and a comparison was made between the two kinds of files. It showed that Cu-based single crystal SMA files are less stiff than the NiTi files. The Cu-based endodontic files could be used to improve the root canal treatments. However, the finite element analysis brought out the need for further investigation based on experiments.

  5. A 1-year randomised controlled trial comparing zirconia versus metal-ceramic implant supported single-tooth restorations

    DEFF Research Database (Denmark)

    Hosseini, Mandana; Worsaae, Nils; Schiodt, Morten

    2011-01-01

    To compare the biological, technical and aesthetic outcomes of single implant-supported all-ceramic versus metal-ceramic crowns.......To compare the biological, technical and aesthetic outcomes of single implant-supported all-ceramic versus metal-ceramic crowns....

  6. Deep learning and shapes similarity for joint segmentation and tracing single neurons in SEM images

    Science.gov (United States)

    Rao, Qiang; Xiao, Chi; Han, Hua; Chen, Xi; Shen, Lijun; Xie, Qiwei

    2017-02-01

    Extracting the structure of single neurons is critical for understanding how they function within the neural circuits. Recent developments in microscopy techniques, and the widely recognized need for openness and standardization provide a community resource for automated reconstruction of dendritic and axonal morphology of single neurons. In order to look into the fine structure of neurons, we use the Automated Tape-collecting Ultra Microtome Scanning Electron Microscopy (ATUM-SEM) to get images sequence of serial sections of animal brain tissue that densely packed with neurons. Different from other neuron reconstruction method, we propose a method that enhances the SEM images by detecting the neuronal membranes with deep convolutional neural network (DCNN) and segments single neurons by active contour with group shape similarity. We joint the segmentation and tracing together and they interact with each other by alternate iteration that tracing aids the selection of candidate region patch for active contour segmentation while the segmentation provides the neuron geometrical features which improve the robustness of tracing. The tracing model mainly relies on the neuron geometrical features and is updated after neuron being segmented on the every next section. Our method enables the reconstruction of neurons of the drosophila mushroom body which is cut to serial sections and imaged under SEM. Our method provides an elementary step for the whole reconstruction of neuronal networks.

  7. Transition from many domain to single domain martensite morphology in small-scale shape memory alloys

    International Nuclear Information System (INIS)

    Ueland, Stian M.; Schuh, Christopher A.

    2013-01-01

    The morphology of the martensitic transformation during a superelastic cycle is studied by in situ scanning electron microscopy deformation experiments in microwires of Cu–Zn–Al. The diameters of the wires studied (21–136 μm) span the range in which significant size effects upon transformation hysteresis have been observed. In larger wires the transformation is accommodated by the continual nucleation of many new martensite plates that grow and eventually coalesce with their neighbors. In small wires a single martensite plate nucleates at the start of transformation and then proceeds to grow in a monolithic fashion; the wire transforms by smooth axial propagation of a single interface. The transition from many domain to single domain transformation is gradual with wire diameter, and is based upon scaling of the domain density with sample size. We attribute it to a crossover from bulk to surface obstacle control of transformation front propagation. This observation also sheds light on reported size effects in energy dissipation in shape memory alloys

  8. Single-Tooth Rehabilitations Supported by Dental Implants Used in an Immediate-Provisionalization Protocol: Report on Long-Term Outcome with Retrospective Follow-Up.

    Science.gov (United States)

    Maló, Paulo; de Araújo Nobre, Miguel; Lopes, Armando; Ferro, Ana; Gravito, Inês

    2015-10-01

    There is a need for long-term studies evaluating the outcome of single-tooth rehabilitations supported by dental implants in immediate loading. To report the long-term outcome (in excess of 5 years) of single-tooth rehabilitations supported by dental implants in an immediate-provisionalization protocol. This retrospective cohort study included 332 consecutive patients (189 females and 143 males) with an average age of 47 years (range: 16 to 82 years) who were rehabilitated between 1996 and 2006 with 594 single crowns supported by dental implants in immediate loading. Implant success rates were calculated based on implant function and using life tables. Marginal bone levels were measured at 5 and 10 years. Mechanical and biological complications were calculated for the follow-up period between implant insertion and 5 years and every 6 months thereafter. Fifty-four patients dropped out of the study (16.5%). Nineteen patients lost a total of 25 implants (n = 23 in the maxilla; n = 2 in the mandible), rendering a cumulative survival rate of 95.7% at both 5 and 10 years of follow-up. The mean marginal bone levels were 1.56 mm (standard deviation 0.78 mm) and 1.75 mm (standard deviation 0.29 mm) at 5 and 10 years of follow-up. Mechanical complications occurred in 83 patients and 116 implants (19.5%) up to the 10-year follow-up, namely prosthetic screw loosening (2.4%), abutment complications (4.4%), fracture of provisional crowns (9.6%), and fracture of definitive ceramic crowns (3.5%). Biological complications occurred in 58 patients and 79 implants (13.3%) up to the 10-year follow-up, with the majority consisting in peri-implant pathology. Considering the high survival rates and stable marginal bone levels after 10 years, it can be concluded within the limitations of the present study that replacement of single teeth with dental implants in an immediate-provisionalization protocol is a viable and safe treatment option for both maxilla and mandible.

  9. Treatment outcome of immediate, early and conventional single-tooth implants in the aesthetic zone : a systematic review to survival, bone level, soft-tissue, aesthetics and patient satisfaction

    NARCIS (Netherlands)

    den Hartog, Laurens; Huddleston Slater, James J. R.; Vissink, Arjan; Meijer, Henny J. A.; Raghoebar, Gerry M.

    2008-01-01

    den Hartog L, Huddleston Slater JJR, Vissink A, Meijer HJA, Raghoebar GM. Treatment outcome of immediate, early and conventional single-tooth implants in the aesthetic zone: a systematic review to survival, bone level, soft-tissue, aesthetics and patient satisfaction. J Clin Periodontol 2008; 35:

  10. Early survival of single-tooth implants in the esthetic zone may be predictable despite timing of implant placement or loading.

    Science.gov (United States)

    Knoernschild, Kent L

    2012-09-01

    -up, survival data were stratified by intervention type. Results were weighted for study size and stratified based upon timing of implant placement and loading. Esthetics, and patient satisfaction, and complications were reported, but heterogeneity of study design and reported outcomes excluded the results from meta-analysis. Approximately two-thirds of patients received implants in healed edentulous sites. Survival of single-tooth implants one year in function was 95.5% [95% CI: 93.0 -97.1]. Meta-analysis identified no difference in survival rate at one year when the results were weighted for study size and stratified based upon timing of implant placement and loading. Survival of single-tooth implants more than one year in function ranged from 92.4% [95% CI: 84.4 -96.4] for conventional placement with immediate loading to 97.5% [95% CI: 88.399.5] for immediate placement with immediate loading. The third meta-analysis identified 0.20-mm [95% CI: 0.034-0.36] marginal bone loss for implants one year in function. Qualitative interpretation of other esthetic, patient satisfaction, and complication outcomes revealed no difference in immediate, early, or conventional therapy approaches. The authors concluded that implant-supported single-tooth replacement in the aesthetic zone with adjacent natural teeth can lead to short-term, favorable outcomes with regard to implant survival and marginal bone level change with early/immediate or conventional surgical placement and loading strategies. Copyright © 2012. Published by Mosby, Inc. All rights reserved.

  11. Tooth wear

    Directory of Open Access Journals (Sweden)

    Tušek Ivan

    2014-01-01

    Full Text Available Tooth wear is the loss of dental hard tissue that was not caused by decay and represents a common clinical problem of modern man. In the etiology of dental hard tissue lesions there are three dominant mechanisms that may act synergistically or separately:friction (friction, which is caused by abrasion of exogenous, or attrition of endogenous origin, chemical dissolution of dental hard tissues caused by erosion, occlusal stress created by compression and flexion and tension that leads to tooth abfraction and microfracture. Wear of tooth surfaces due to the presence of microscopic imperfections of tooth surfaces is clinically manifested as sanding veneers. Tribology, as an interdisciplinary study of the mechanisms of friction, wear and lubrication at the ultrastructural level, has defined a universal model according to which the etiopathogenesis of tooth wear is caused by the following factors: health and diseases of the digestive tract, oral hygiene, eating habits, poor oral habits, bruxism, temporomandibular disorders and iatrogenic factors. Attrition and dental erosion are much more common in children with special needs (Down syndrome. Erosion of teeth usually results from diseases of the digestive tract that lead to gastroesophageal reflux (GER of gastric juice (HCl. There are two basic approaches to the assessment of the degree of wear and dental erosion. Depending on the type of wear (erosion, attrition, abfraction, the amount of calcium that was realised during the erosive attack could be determined qualitatively and quantitatively, or changes in optical properties and hardness of enamel could be recorded, too. Abrasion of teeth (abrasio dentium is the loss of dental hard tissue caused by friction between the teeth and exogenous foreign substance. It is most commonly provoked by prosthetic dentures and bad habits, while its effect depends on the size of abrasive particles and their amount, abrasive particle hardness and hardness of tooth

  12. Electropolishing on single-cell: (TESLA, Reentrant and Low Loss shapes) Comsol modelling

    Energy Technology Data Exchange (ETDEWEB)

    Bruchon, M

    2007-07-01

    In the framework of improvement of cavity electropolishing, modelling permits to evaluate some parameters not easily accessible by experiments and can also help us to guide them. Different laboratories (DESY, Fermilab) work on electro or chemical polishing modelling with different approaches and softwares. At CEA Saclay, COMSOL software is used to model horizontal electropolishing of cavity in two dimensions. The goal of this study has been motivated by improvement of our electropolishing setup by modifying the arrival of the acid. The influence of a protuberant cathode has been evaluated and compared for different shapes of single cell cavities: TESLA, ILC Low Loss (LL{sub ILC}), and ILC Reentrant (RE{sub ILC}). (author)

  13. Coupled stress-strain and electrical resistivity measurements on copper based shape memory single crystals

    Directory of Open Access Journals (Sweden)

    Gonzalez Cezar Henrique

    2004-01-01

    Full Text Available Recently, electrical resistivity (ER measurements have been done during some thermomechanical tests in copper based shape memory alloys (SMA's. In this work, single crystals of Cu-based SMA's have been studied at different temperatures to analyse the relationship between stress (s and ER changes as a function of the strain (e. A good consistency between ER change values is observed in different experiments: thermal martensitic transformation, stress induced martensitic transformation and stress induced reorientation of martensite variants. During stress induced martensitic transformation (superelastic behaviour and stress induced reorientation of martensite variants, a linear relationship is obtained between ER and strain as well as the absence of hys teresis. In conclusion, the present results show a direct evidence of martensite electrical resistivity anisotropy.

  14. Shapes of Exotic Nuclei by Single- and Multi-Step Coulomb Excitation

    Science.gov (United States)

    Allmond, J. M.; Clarion-Bareball Collaboration; Gretina-Chico2 Collaboration

    2017-09-01

    Coulomb excitation is a powerful technique for probing the shell structure, collectivity, and shapes of atomic nuclei through the measurement of electromagnetic moments. Single- and multi-step Coulomb excitation results from CLARION-BareBall at HRIBF-ORNL (e.g., 136Te) and GRETINA-CHICO2 at CARIBU-ANL (e.g., 106Mo and 106,110Ru) will be presented. A survey of the equipment, techniques, and results will be given. An emphasis will be placed on unique opportunities with 3-MeV/u beams and future directions at CARIBU and ReA3. This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics.

  15. Nanocatalyst shape and composition during nucleation of single-walled carbon nanotubes.

    Science.gov (United States)

    Gomez-Ballesteros, Jose L; Burgos, Juan C; Lin, Pin Ann; Sharma, Renu; Balbuena, Perla B

    The dynamic evolution of nanocatalyst particle shape and carbon composition during the initial stages of single-walled carbon nanotube growth by chemical vapor deposition synthesis is investigated. Classical reactive and ab initio molecular dynamics simulations are used, along with environmental transmission electron microscope video imaging analyses. A clear migration of carbon is detected from the nanocatalyst/substrate interface, leading to a carbon gradient showing enrichment of the nanocatalyst layers in the immediate vicinity of the contact layer. However, as the metal nanocatalyst particle becomes saturated with carbon, a dynamic equilibrium is established, with carbon precipitating on the surface and nucleating a carbon cap that is the precursor of nanotube growth. A carbon composition profile decreasing towards the nanoparticle top is clearly revealed by the computational and experimental results that show a negligible amount of carbon in the nanoparticle region in contact with the nucleating cap. The carbon composition profile inside the nanoparticle is accompanied by a well-defined shape evolution of the nanocatalyst driven by the various opposing forces acting upon it both from the substrate and from the nascent carbon nanostructure. This new understanding suggests that tuning the nanoparticle/substrate interaction would provide unique ways of controlling the nanotube synthesis.

  16. Creating a Single-Visit, Fibre-Reinforced, Composite Resin Bridge by Using a Natural Tooth Pontic: A Viable Alternative to a PFM Bridge

    OpenAIRE

    Khetarpal, Ambica; Talwar, Sangeeta; Verma, Mahesh

    2013-01-01

    Background: The rehabilitation of an anterior tooth space presents a confronting situation. Several modalities are presently available to address the challenge of an immediate replacement of a missing anterior tooth. These include a removable temporary acrylic prosthesis or resin-bonded bridges. Fibre-Reinforced Composite (FRC) bridges are preferable if they are fixed and if a cost-effective tooth replacement is desired. Also, they provide an aesthetic and a conservative treatment choice as t...

  17. Esthetic outcome evaluation of maxillary anterior single-tooth bone-level implants with metal or ceramic abutments and ceramic crowns.

    Science.gov (United States)

    Vanlıoğlu, Burçin Akoğlu; Kahramanoğlu, Erkut; Yıldız, Coşkun; Ozkan, Yaşar; Kulak-Özkan, Yasemin

    2014-01-01

    The aim of this study was to evaluate the treatment outcome of implants placed in the maxillary anterior segment. Patients were treated with bone-level implants (Straumann Bone Level Implant, Institut Straumann) that supported all-ceramic single crowns and were followed for 2 to 4 years. Titanium or ceramic abutments were used according to the quality of the soft tissue at each site. Esthetic parameters were recorded to assess treatment outcomes. Pink esthetic scores (PES) and white esthetic scores (WES) were used to evaluate the esthetic outcome of anterior single-tooth implant-supported crowns. Patient satisfaction was also evaluated by means of a questionnaire. Fifty-five implants were placed in 47 patients. At the recall examinations, all implants were confirmed to have successfully integrated and demonstrated healthy peri-implant soft tissues, as documented by generally accepted clinical parameters. Overall, the esthetic results were considered favorable, and there were no significant differences between restorations with ceramic or titanium abutments. WES values were slightly superior to PES values. None of the implants had mucosal recession. Objective and subjective evaluation of maxillary bone-level implants in the esthetic zone yielded satisfactory results. Pleasing esthetic outcomes and stable facial soft tissues were achieved.

  18. Single Molecule Study on Polymer-Nanoparticle Interactions: The Particle Shape Matters.

    Science.gov (United States)

    Li, Zhandong; Zhang, Bin; Song, Yu; Xue, Yurui; Wu, Lixin; Zhang, Wenke

    2017-08-08

    The study on the nanoparticle-polymer interactions is very important for the design/preparation of high performance polymer nanocomposite. Here we present a method to quantify the polymer-particle interaction at single molecule level by using AFM-based single molecule force spectroscopy (SMFS). As a proof-of-concept study, we choose poly-l-lysine (PLL) as the polymer and several different types of polyoxometalates (POM) as the model particles to construct several different polymer nanocomposites and to reveal the binding mode and quantify the binding strength in these systems. Our results reveal that the shape of the nanoparticle and the binding geometry in the composite have significantly influenced the binding strength of the PLL/POM complexes. Our dynamic force spectroscopy studies indicate that the disk-like geometry facilitate the unbinding of PLL/AlMo 6 complexes in shearing mode, while the unzipping mode becomes dominate in spherical PLL-P 8 W 48 system. We have also systematically investigated the effects of charge numbers, particle size, and ionic strength on the binding strength and binding mode of PLL/POM, respectively. Our results show that electrostatic interactions dominate the stability of PLL/POM complexes. These findings provide a way for tuning the mechanical properties of polyelectrolyte-nanoparticle composites.

  19. Shape evolution and single particle luminescence of organometal halide perovskite nanocrystals.

    Science.gov (United States)

    Zhu, Feng; Men, Long; Guo, Yijun; Zhu, Qiaochu; Bhattacharjee, Ujjal; Goodwin, Peter M; Petrich, Jacob W; Smith, Emily A; Vela, Javier

    2015-03-24

    Organometallic halide perovskites CH3NH3PbX3 (X = I, Br, Cl) have quickly become one of the most promising semiconductors for solar cells, with photovoltaics made of these materials reaching power conversion efficiencies of near 20%. Improving our ability to harness the full potential of organometal halide perovskites will require more controllable syntheses that permit a detailed understanding of their fundamental chemistry and photophysics. In this manuscript, we systematically synthesize CH3NH3PbX3 (X = I, Br) nanocrystals with different morphologies (dots, rods, plates or sheets) by using different solvents and capping ligands. CH3NH3PbX3 nanowires and nanorods capped with octylammonium halides show relatively higher photoluminescence (PL) quantum yields and long PL lifetimes. CH3NH3PbI3 nanowires monitored at the single particle level show shape-correlated PL emission across whole particles, with little photobleaching observed and very few off periods. This work highlights the potential of low-dimensional organometal halide perovskite semiconductors in constructing new porous and nanostructured solar cell architectures, as well as in applying these materials to other fields such as light-emitting devices and single particle imaging and tracking.

  20. Single cigar-shaped nanopores functionalized with amphoteric amino acid chains: experimental and theoretical characterization.

    Science.gov (United States)

    Ali, Mubarak; Ramirez, Patricio; Nguyen, Hung Quoc; Nasir, Saima; Cervera, Javier; Mafe, Salvador; Ensinger, Wolfgang

    2012-04-24

    We present an experimental and theoretical characterization of single cigar-shaped nanopores with pH-responsive carboxylic acid and lysine chains functionalized on the pore surface. The nanopore characterization includes (i) optical images of the nanostructure obtained by FESEM; (ii) different chemical procedures for the nanopore preparation (etching time and functionalizations; pH and electrolyte concentration of the external solution) allowing externally tunable nanopore responses monitored by the current-voltage (I-V) curves; and (iii) transport simulations obtained with a multilayer nanopore model. We show that a single, approximately symmetric nanopore can be operated as a reconfigurable diode showing different rectifying behaviors by applying chemical and electrical signals. The remarkable characteristics of the new nanopore are the sharp response observed in the I-V curves, the improved tunability (with respect to previous designs of symmetric nanopores) which is achieved because of the direct external access to the nanostructure mouths, and the broad range of rectifying properties. The results concern both fundamental concepts useful for the understanding of transport processes in biological systems (ion channels) and applications relevant for tunable nanopore technology (information processing and drug controlled release).

  1. Single-tooth replacement in the anterior maxilla by means of immediate implantation and early loading: clinical and aesthetic results at 5 years.

    Science.gov (United States)

    Guarnieri, Renzo; Ceccherini, Alessandro; Grande, Maurizio

    2015-04-01

    The hypothesis of the present study was that the early loading of single implants-supported restorations, replacing single extracting teeth in the anterior region of the maxilla in case of fresh extraction sockets with residual hard and soft tissue preservation, could be a successful procedure. Twenty-one implants were placed into maxillary anterior fresh extraction sockets using a flapless technique. Temporary restorations, which were fabricated from the impression taken immediately after implant placement, were connected within 2 weeks. These temporary restorations were adjusted in order to avoid any direct occlusive contacts. Six months after implantation, the implants were restored with single-teeth all-ceramic prostheses. Patients were followed for 5 years. Radiographic and clinical examinations were made at baseline, at time of definitive crowns delivery, and each subsequent year. Survival rate, cortical bone responses, and peri-implant mucosal responses were evaluated. One implant was lost at 6 months. Clinical osseointegration of 20 implants was achieved (95.2% implant survival rate after 5 years) with minimal gingival recession and papillae preservation. The mean change in marginal cortical bone level was 0.40 mm at 6 months and 0.83 mm at 5 years. Within the limit of the present study, the data indicate that, under a strictly controlled oral hygienic regimen, single-tooth implants, with immediate placement and early loading protocol, may be used in anterior maxillary fresh extraction sockets with residual hard and soft tissues preservation, if patients are selected carefully and if high primary stability is strictly followed. © 2013 Wiley Periodicals, Inc.

  2. Esthetic Evaluation of Anterior Single-Tooth Implants with Different Abutment Designs - Patients' Satisfaction Compared to Dentists' Observations

    NARCIS (Netherlands)

    Patil, Ratnadeep; Gresnigt, Marco M M; Mahesh, Kavita; Dilbaghi, Anjali; Cune, Marco S

    Purpose: To correlate patients' satisfaction and dentists' observations regarding two abutment designs used for single crowns in the esthetic zone: a divergent one (control) and a curved one (experimental), with special emphasis on muco-gingival esthetics. Materials and Methods: Twenty-six patients

  3. Analysis and enhancement of 3D shape accuracy in a single-shot LIDAR sensor

    Science.gov (United States)

    Han, Munhyun; Choi, Gudong; Song, Minhyup; Seo, Hongseok; Mheen, Bongki

    2017-02-01

    The accuracy of timing jitter is of prime importance in the prevalent utilization of Light Detection and Ranging (LiDAR) technology for the real-time high-resolution three-dimensional (3D) image sensor, especially for relatively small object detection in various applications, such as in the fully automated car navigation and military surveillance. To assess the accuracy of timing, that is, the accuracy of the distance or three-dimensional shape, the standard deviation method can be used in the Time-of-Flight (ToF) LiDAR technology. While most timing jitter analyses are mainly based on a fiber-network or open space at a relatively short range distance, more accurate analyses are required to extract more information about the timing jitter at in a 3D image sensor long-range free space conditions for extended LiDAR-related applications. In this paper, utilizing a Single-Shot LiDAR System (SSLs) model with a 400 MHz wideband InGaAs Avalanche Photodiode and a 1550 nm 2 nsec full width at half maximum MOPA fiber laser, we analyzed the precise timing jitter for the implemented SSLs to characterize the measurement results. Additionally, we report the enhanced results for the resolution and precision in the given SSLs using the spline interpolation method from the measured results, and multiple-shot averaging (MSA). Finally, by adapting the proposed method to an implemented high resolution 3D LiDAR prototype, called the STUD LiDAR prototype, which can be understood as one kind of SSLs because it has a single source and a single detector as in a SSLs, we observed and analyzed the 3D resolution enhancement.

  4. Temporización inmediata de implantes unitarios en la maxila posterior Immediate temporization of posterior maxilla single tooth implant

    Directory of Open Access Journals (Sweden)

    Y Leighton

    2011-04-01

    clinical study observed 21 partially edentulous subjects with lip scar and antagonistic natural teeth in the posterior maxilla for a period of 6 months in which conical threaded internal implant connections were inserted with a surface treatment and timed immediately after being inserted into the jawbone by producing an acrylic resin crown on a temporary titanium abutment screwed directly into the implant and left without tooth contacts during the Maximal Intercuspal (MIC and mandibular eccentric movements. All restorations were observed over a period of 6 months evaluating implant success rate and biological and mechanical complications. Results: 25 implants were inserted into 21 patients yielding an average surgical insertion torque of 45.6 Nt. During the clinical observation there was 100% success of implant survival. No biological complications were detected, but there were mechanical complications - a buccal cusp fracture of an acrylic provisional restoration and two screws loosening. Conclusions: The unit temporization by temporary screwing is a predictable and reliable protocol that allows osseointegration and the coexistence in the health of peri-implant tissue and its prosthetic system.

  5. Three-year analysis of zirconia implants used for single-tooth replacement and three-unit fixed dental prostheses: A prospective multicenter study.

    Science.gov (United States)

    Balmer, Marc; Spies, Benedikt C; Vach, Kirstin; Kohal, Ralf-Joachim; Hämmerle, Christoph H F; Jung, Ronald E

    2018-03-01

    The aim of the present investigation was to evaluate clinically and radiographically the outcome of zirconia oral implants after 3 years in function. In 60 patients in need of either a single-tooth replacement or a three-unit fixed dental prosthesis (FDP), a total of 71 one-piece zirconia implants were placed and immediately restored with temporary fixed prostheses. After a period of at least 2 months in the mandible and at least 4 months in the maxilla, zirconia-based reconstructions were cemented. The implants were clinically and radiologically examined at implant insertion, prosthetic delivery, at 6 months and then yearly up to 3 years. A linear mixed model was used to analyze statistically the influence of prognostic factors on changes in the marginal bone level. Seventy-one implants (48 in the mandible, 23 in the maxilla) inserted in 60 patients were restored with 49 crowns and 11 FDP. One patient lost his implant after 5 weeks. Five patients with one implant each could not be evaluated after 3 years. Based on 55 patients with a total of 66 implants, the mean survival rate was 98.5% after 3 years in function. A statistically significant mean marginal bone loss (0.70 mm ± 0.72 mm) has been detected from implant insertion to the 3-year follow-up. The largest marginal bone loss occurred between implantation and prosthetic delivery (0.67 mm ± 0.56 mm). After delivery, no statistically significant bone level change was observed (0.02 mm ± 0.59 mm). None of the investigated prognostic factors had a significant influence on changes in the marginal bone level. After 3 years in function, the investigated one-piece zirconia implant showed a high survival rate and a low marginal bone loss. The implant system was successful for single-tooth replacement and three-unit FDPs. Further investigations with long-term data are needed to confirm these findings. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Evolution of high tooth replacement rates in sauropod dinosaurs.

    Science.gov (United States)

    D'Emic, Michael D; Whitlock, John A; Smith, Kathlyn M; Fisher, Daniel C; Wilson, Jeffrey A

    2013-01-01

    Tooth replacement rate can be calculated in extinct animals by counting incremental lines of deposition in tooth dentin. Calculating this rate in several taxa allows for the study of the evolution of tooth replacement rate. Sauropod dinosaurs, the largest terrestrial animals that ever evolved, exhibited a diversity of tooth sizes and shapes, but little is known about their tooth replacement rates. We present tooth replacement rate, formation time, crown volume, total dentition volume, and enamel thickness for two coexisting but distantly related and morphologically disparate sauropod dinosaurs Camarasaurus and Diplodocus. Individual tooth formation time was determined by counting daily incremental lines in dentin. Tooth replacement rate is calculated as the difference between the number of days recorded in successive replacement teeth. Each tooth family in Camarasaurus has a maximum of three replacement teeth, whereas each Diplodocus tooth family has up to five. Tooth formation times are about 1.7 times longer in Camarasaurus than in Diplodocus (315 vs. 185 days). Average tooth replacement rate in Camarasaurus is about one tooth every 62 days versus about one tooth every 35 days in Diplodocus. Despite slower tooth replacement rates in Camarasaurus, the volumetric rate of Camarasaurus tooth replacement is 10 times faster than in Diplodocus because of its substantially greater tooth volumes. A novel method to estimate replacement rate was developed and applied to several other sauropodomorphs that we were not able to thin section. Differences in tooth replacement rate among sauropodomorphs likely reflect disparate feeding strategies and/or food choices, which would have facilitated the coexistence of these gigantic herbivores in one ecosystem. Early neosauropods are characterized by high tooth replacement rates (despite their large tooth size), and derived titanosaurs and diplodocoids independently evolved the highest known tooth replacement rates among archosaurs.

  7. Evolution of high tooth replacement rates in sauropod dinosaurs.

    Directory of Open Access Journals (Sweden)

    Michael D D'Emic

    Full Text Available BACKGROUND: Tooth replacement rate can be calculated in extinct animals by counting incremental lines of deposition in tooth dentin. Calculating this rate in several taxa allows for the study of the evolution of tooth replacement rate. Sauropod dinosaurs, the largest terrestrial animals that ever evolved, exhibited a diversity of tooth sizes and shapes, but little is known about their tooth replacement rates. METHODOLOGY/PRINCIPAL FINDINGS: We present tooth replacement rate, formation time, crown volume, total dentition volume, and enamel thickness for two coexisting but distantly related and morphologically disparate sauropod dinosaurs Camarasaurus and Diplodocus. Individual tooth formation time was determined by counting daily incremental lines in dentin. Tooth replacement rate is calculated as the difference between the number of days recorded in successive replacement teeth. Each tooth family in Camarasaurus has a maximum of three replacement teeth, whereas each Diplodocus tooth family has up to five. Tooth formation times are about 1.7 times longer in Camarasaurus than in Diplodocus (315 vs. 185 days. Average tooth replacement rate in Camarasaurus is about one tooth every 62 days versus about one tooth every 35 days in Diplodocus. Despite slower tooth replacement rates in Camarasaurus, the volumetric rate of Camarasaurus tooth replacement is 10 times faster than in Diplodocus because of its substantially greater tooth volumes. A novel method to estimate replacement rate was developed and applied to several other sauropodomorphs that we were not able to thin section. CONCLUSIONS/SIGNIFICANCE: Differences in tooth replacement rate among sauropodomorphs likely reflect disparate feeding strategies and/or food choices, which would have facilitated the coexistence of these gigantic herbivores in one ecosystem. Early neosauropods are characterized by high tooth replacement rates (despite their large tooth size, and derived titanosaurs and

  8. Facial bone alterations on maxillary anterior single implants for immediate placement and provisionalization following tooth extraction: a superimposed cone beam computed tomography study.

    Science.gov (United States)

    Morimoto, Taichiro; Tsukiyama, Yoshihiro; Morimoto, Keizo; Koyano, Kiyoshi

    2015-12-01

    The purpose of this cone beam computed tomography (CBCT) study was to describe the facial bone changes around single implants for immediate placement and provisionalization following tooth extraction in the maxillary anterior. The data between 2008 and 2013 were collected retrospectively. Superimposed facio-palatal cross-sectional CBCT images for the implants were derived from preoperative and postoperative radiographs via standardized CBCT processes. Horizontal and vertical facial measurements on the implants were identified at preoperative and approximately 1-year postoperative follow-ups. Correlation coefficient for those parameters was evaluated. A total of 12 single implants in 12 patients were included in this study. The mean loading period was 13.3 months (range 12-15 months). The median data of preoperative bone thickness 0.54 mm (A), preoperative vertical bone level 1.46 mm (B), postoperative bone thickness 1.77 mm (C), postoperative vertical bone level 1.08 mm (D), horizontal distance from outer surface of preoperative facial bone to implant surface 2.08 mm (E), horizontal gap distance 1.41 mm (E-A), horizontal bone resorption -0.26 mm (E-C), and vertical bone resorption -0.25 mm (B-D) were obtained. The data at the implant platform level (IPL) were selected for the horizontal measurements. Spearman's analysis demonstrated statistically significant correlations between B and D, C and E, E and E-A, and B and E-C (P Immediate placement and provisionalization of single implants procedure in the maxillary anterior showed excellent outcomes with the small facial bone alterations around the implants. Neither preoperative facial bone thickness nor horizontal gap distance influenced the amount of facial bone resorptions. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Single-molecule imaging reveals topological isomer-dependent diffusion by 4-armed star and dicyclic 8-shaped polymers

    KAUST Repository

    Habuchi, Satoshi

    2015-04-21

    Diffusion dynamics of topological isomers of polymer molecules was investigated at the single-molecule level in a melt state by employing the fluorophore-incorporated 4-armed star and the corresponding doubly-cyclized, 8-shaped poly(THF) chains. While the single-molecule fluorescence imaging experiment revealed that the diffusion of the 4-armed star polymer was described by a single Gaussian distribution, the diffusion of the 8-shaped polymer exhibited a double Gaussian distribution behaviour. We reasoned that the two 8-shaped polymeric isomers have distinct diffusion modes in the melt state, although ensemble-averaged experimental methods cannot detect differences in overall conformational state of the isomers. The single-molecule experiments suggested that one of the 8-shaped polymeric isomer, having the horizontally oriented form, causes an efficient threading with the linear matrix chains which leads to the slower diffusion compared with the corresponding 4-armed star polymer, while the other 8-shaped polymeric isomer, having the vertically oriented form, displayed faster diffusion by the suppression of effective threading with the linear matrix chains due to its contracted chain conformation.

  10. Functional aspects of treatment with implant-supported single crowns: a quality control study in subjects with tooth agenesis

    DEFF Research Database (Denmark)

    Goshima, Kenichi; Lexner, Michala O; Thomsen, Carsten Eckhart

    2010-01-01

    after implant placement shortly before crown cementation, and again 1 month after cementation. It consisted of questionnaires [including Oral Health Impact Profile (OHIP-49)] and functional examination with plastic strips, the Dental Prescale Film and the Occluzer system, Xylitol color-changeable gum......BACKGROUND: No comprehensive patient-centered and clinical evaluations of the functional effect of treatment with implant-supported single crowns (ISSC) have been reported previously. OBJECTIVE: To investigate whether and how treatment with ISSC affects masticatory function and Oral Health...

  11. Unusual presentation of 'u-shaped' impacted maxillary central incisor with intranasal root: successful surgical management.

    Science.gov (United States)

    Punde, Prashant A; Patil, Nilesh M; Pawar, Renuka L

    2014-07-01

    Dilacerations is a tooth deformity characterized by an angulation between crown and root causing non-eruption of the tooth. It generally occurs following trauma to the deciduous dentition apices of which lie close to the permanent tooth buds. According to Neville, maxillary and mandibular incisors contribute only approximately to 1% of the incidence of dilacerated teeth. A 15 year old male patient reported with chief complaint of missing anterior teeth in the left side of maxillary arch. Radiographic evaluation showed impacted maxillary left central incisor. The radiograph depicted very unusual extreme curve in the root of the same tooth giving it characteristic U-morphology. The root of this tooth was curving into the nasal cavity. Due to extreme curve, surgical removal was suggested by orthodontist. Surgically removing this highly placed tooth with apex into nasal cavity was a surgical challenge. This was done effectively by removing the tooth under local anesthesia itself. U-shaped morphology in single rooted tooth is observed very rarely. This root curvature predisposes to fracture of root during surgical removal. Proper surgical protocol is to be followed during surgical removal of a tooth with such extreme root curvature to prevent fracture of the root and accidental displacement of the tooth into nasal cavity.

  12. Intentional replantation of periodontally compromised hopeless tooth

    Science.gov (United States)

    Nagappa, G.; Aspalli, Shivanand; Devanoorkar, Archana; Shetty, Sudhir; Parab, Prachi

    2013-01-01

    Aesthetic considerations have influenced the management of dental maladies in varying degrees for many years. Even single tooth mal-alignment makes the patient to approach a dentist. Intentional replantation is a procedure in which an intentional tooth extraction is performed followed by reinsertion of the extracted tooth. Many authors agree that it should be reserved as the last resort to save a tooth after other procedures have failed or would likely to fail. The main reason of failure in replanted teeth is root resorption, specifically ankylosis or replacement resorption. Although the success rate is not always high, intentional replantation may be a treatment alternative that deserves consideration to maintain the natural dentition and avoid extraction of the tooth. Here is case report of a patient desiring alignment of malpositioned periodontally involved anterior single tooth due to various causes treated by intentional replantation. PMID:24174765

  13. Intentional replantation of periodontally compromised hopeless tooth

    Directory of Open Access Journals (Sweden)

    G Nagappa

    2013-01-01

    Full Text Available Aesthetic considerations have influenced the management of dental maladies in varying degrees for many years. Even single tooth mal-alignment makes the patient to approach a dentist. Intentional replantation is a procedure in which an intentional tooth extraction is performed followed by reinsertion of the extracted tooth. Many authors agree that it should be reserved as the last resort to save a tooth after other procedures have failed or would likely to fail. The main reason of failure in replanted teeth is root resorption, specifically ankylosis or replacement resorption. Although the success rate is not always high, intentional replantation may be a treatment alternative that deserves consideration to maintain the natural dentition and avoid extraction of the tooth. Here is case report of a patient desiring alignment of malpositioned periodontally involved anterior single tooth due to various causes treated by intentional replantation.

  14. Intentional replantation of periodontally compromised hopeless tooth.

    Science.gov (United States)

    Nagappa, G; Aspalli, Shivanand; Devanoorkar, Archana; Shetty, Sudhir; Parab, Prachi

    2013-09-01

    Aesthetic considerations have influenced the management of dental maladies in varying degrees for many years. Even single tooth mal-alignment makes the patient to approach a dentist. Intentional replantation is a procedure in which an intentional tooth extraction is performed followed by reinsertion of the extracted tooth. Many authors agree that it should be reserved as the last resort to save a tooth after other procedures have failed or would likely to fail. The main reason of failure in replanted teeth is root resorption, specifically ankylosis or replacement resorption. Although the success rate is not always high, intentional replantation may be a treatment alternative that deserves consideration to maintain the natural dentition and avoid extraction of the tooth. Here is case report of a patient desiring alignment of malpositioned periodontally involved anterior single tooth due to various causes treated by intentional replantation.

  15. One-piece zirconia oral implants for single-tooth replacement: Three-year results from a long-term prospective cohort study.

    Science.gov (United States)

    Kohal, Ralf-Joachim; Spies, Benedikt C; Bauer, Annalena; Butz, Frank

    2018-01-01

    This 3-year report of a prospective long-term cohort investigation aimed to evaluate the clinical and radiographic outcomes of a one-piece zirconia oral implant for single-tooth replacement. Sixty-five patients received a 1-stage implant surgery with immediate temporization. Standardized radiographs were taken at implant insertion, after 1 year, and after 3 years to monitor peri-implant bone levels. A univariate analysis of the association of different baseline parameters on marginal bone loss from implant insertion to 36 months was performed. Soft-tissue parameters were evaluated at prosthesis insertion, after 6 months, after 1 year, and at the 3-year follow-up. After 3 years, six posterior site implants were lost, giving a cumulative survival rate of 90.8%. The mean marginal bone loss was 1.45 mm; 35% of the implants lost at least 2 mm bone, and 22% more than 3 mm. The univariate analysis did not identify any parameter associated with marginal bone loss. Probing depth, clinical attachment level, and bleeding index increased over 3 years, and plaque index decreased. The low survival rate of the presented ceramic implant and especially the high frequency of advanced bone loss are noticeable but remain unexplained. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Structural and magnetic properties evolution study method using a single ribbon-shaped sample

    Science.gov (United States)

    Moya, Javier A.

    2017-06-01

    A new type of study is presented for magnetic and structural characterization of amorphous or nanocrystalline metallic alloys in ribbon or wire-shaped samples. A single sample is subjecting to successive steps of flash isocurrent heat treatments with increasing duration in time, followed by a rapid cooling, while magneto-electric properties evolution are scanned in situ at room temperature. When one set of isocurrent heat treatments is finished, the annealing current is increased and a new set of isocurrent treatments starts. The properties studied were the saturation magnetization and the coercive field at 50 Hz, magnetic permeability at 100 kHz and electrical resistance from where we also obtained the crystalline fraction. The method was applied on two samples of Finemet-like alloys and the results were analyzed from the perspective of current literature. With the present method it is possible to obtain a general and meticulous understanding of the structural and magnetic evolution of the samples tested, with a considerable saving of time and samples.

  17. A novel L-shaped linear ultrasonic motor operating in a single resonance mode

    Science.gov (United States)

    Zhang, Bailiang; Yao, Zhiyuan; Liu, Zhen; Li, Xiaoniu

    2018-01-01

    In this study, a large thrust linear ultrasonic motor using an L-shaped stator is described. The stator is constructed by two mutually perpendicular rectangular plate vibrators, one of which is mounted in parallel with the slider to make the motor structure to be more compact. The symmetric and antisymmetric modes of the stator based on the first order bending vibration of two vibrators are adopted, in which each resonance mode is assigned to drive the slider in one direction. The placement of piezoelectric ceramics in a stator could be determined by finite element analysis, and the influence of slots in the head block on the vibration amplitudes of driving foot was studied as well. Three types of prototypes (non-slotted, dual-slot, and single-slot) were fabricated and experimentally investigated. Experimental results demonstrated that the prototype with one slot exhibited the best mechanical output performance. The maximum loads under the excitation of symmetric mode and antisymmetric mode were 65 and 90 N, respectively.

  18. Single-feature polymorphism discovery by computing probe affinity shape powers

    Directory of Open Access Journals (Sweden)

    Jia Haiyan

    2009-08-01

    Full Text Available Abstract Background Single-feature polymorphism (SFP discovery is a rapid and cost-effective approach to identify DNA polymorphisms. However, high false positive rates and/or low sensitivity are prevalent in previously described SFP detection methods. This work presents a new computing method for SFP discovery. Results The probe affinity differences and affinity shape powers formed by the neighboring probes in each probe set were computed into SFP weight scores. This method was validated by known sequence information and was comprehensively compared with previously-reported methods using the same datasets. A web application using this algorithm has been implemented for SFP detection. Using this method, we identified 364 SFPs in a barley near-isogenic line pair carrying either the wild type or the mutant uniculm2 (cul2 allele. Most of the SFP polymorphisms were identified on chromosome 6H in the vicinity of the Cul2 locus. Conclusion This SFP discovery method exhibits better performance in specificity and sensitivity over previously-reported methods. It can be used for other organisms for which GeneChip technology is available. The web-based tool will facilitate SFP discovery. The 364 SFPs discovered in a barley near-isogenic line pair provide a set of genetic markers for fine mapping and future map-based cloning of the Cul2 locus.

  19. All-ceramic or metal-ceramic tooth-supported fixed dental prostheses (FDPs)? A systematic review of the survival and complication rates. Part I: Single crowns (SCs).

    Science.gov (United States)

    Sailer, Irena; Makarov, Nikolay Alexandrovich; Thoma, Daniel Stefan; Zwahlen, Marcel; Pjetursson, Bjarni Elvar

    2015-06-01

    To assess the 5-year survival of metal-ceramic and all-ceramic tooth-supported single crowns (SCs) and to describe the incidence of biological, technical and esthetic complications. Medline (PubMed), Embase, Cochrane Central Register of Controlled Trials (CENTRAL) searches (2006-2013) were performed for clinical studies focusing on tooth-supported fixed dental prostheses (FDPs) with a mean follow-up of at least 3 years. This was complimented by an additional hand search and the inclusion of 34 studies from a previous systematic review [1,2]. Survival and complication rates were analyzed using robust Poisson's regression models to obtain summary estimates of 5-year proportions. Sixty-seven studies reporting on 4663 metal-ceramic and 9434 all-ceramic SCs fulfilled the inclusion criteria. Seventeen studies reported on metal-ceramic crowns, and 54 studies reported on all-ceramic crowns. Meta-analysis of the included studies indicated an estimated survival rate of metal-ceramic SCs of 94.7% (95% CI: 94.1-96.9%) after 5 years. This was similar to the estimated 5-year survival rate of leucit or lithium-disilicate reinforced glass ceramic SCs (96.6%; 95% CI: 94.9-96.7%), of glass infiltrated alumina SCs (94.6%; 95% CI: 92.7-96%) and densely sintered alumina and zirconia SCs (96%; 95% CI: 93.8-97.5%; 92.1%; 95% CI: 82.8-95.6%). In contrast, the 5-year survival rates of feldspathic/silica-based ceramic crowns were lower (pcrowns exhibited significantly lower survival rates in the posterior region (pcrown types performed similarly. Densely sintered zirconia SCs were more frequently lost due to veneering ceramic fractures than metal-ceramic SCs (p<0.001), and had significantly more loss of retention (p<0.001). In total higher 5 year rates of framework fracture were reported for the all-ceramic SCs than for metal-ceramic SCs. Survival rates of most types of all-ceramic SCs were similar to those reported for metal-ceramic SCs, both in anterior and posterior regions. Weaker

  20. Reactive Stresses in Ni49Fe18Ga27Co6 Shape-Memory-Alloy Single Crystals

    Science.gov (United States)

    Averkin, A. I.; Krymov, V. M.; Guzilova, L. I.; Timashov, R. B.; Soldatov, A. V.; Nikolaev, V. I.

    2018-03-01

    The reactive stresses induced in Ni49Fe18Ga27Co6-alloy single crystals during martensitic transformations with a limited possibility of shape-memory-strain recovery have been experimentally studied. The data on these crystals are compared with the results obtained previously for Cu-Al-Ni, Ni-Ti, and Ni‒Fe-Ga crystals. The potential of application of the Ni49Fe18Ga27Co6 single crystals in designing drives and power motors is demonstrated.

  1. Randomized Controlled Clinical Trial of All-Ceramic Single Tooth Implant Reconstructions Using Modified Zirconia Abutments: Radiographic and Prosthetic Results at 1 Year of Loading.

    Science.gov (United States)

    Thoma, Daniel S; Brandenberg, Francine; Fehmer, Vincent; Büchi, Dominik L E; Hämmerle, Christoph H F; Sailer, Irena

    2016-06-01

    This study aims to test whether or not veneering of the submucosal part of zirconia abutments with pink dental ceramic affects radiographic and technical outcomes of implant-supported single crowns (ISSC). Single tooth implants were randomly restored with either pink-veneered zirconia abutments (test; n = 10) or non-veneered zirconia abutments (control group; n = 10) and all-ceramic crowns. At baseline (crown insertion), and 6- and 12-month radiographic and technical evaluations were performed including standardized x-rays and modified United States Public Health Service criteria (technical). Survival and complication rates were assessed for implants and restorations. Robust linear mixed model analysis was performed to investigate the effect of group and time-point on radiographic outcomes. At 1 year, the survival rate for implants was 100% and 95% for ISSC. Most of the implants were placed subcrestally. Therefore, mean marginal bone levels decreased in both groups between implant insertion and baseline (p  .005). At 6 months, one minor chipping occurred in the test group. At 1 year, three crowns (control) exhibited occlusal roughness. In addition, one abutment fracture occurred (test). The differences between test and control group were not statistically significantly different for any of the evaluated outcome measures (p > .05). Veneering of the submucosal part of zirconia abutments did not affect biological and technical outcomes of ISSCs. Technical complications of the reconstructions, however, were frequent, resulting in a rate of 75% of the crowns being complication free. © 2015 Wiley Periodicals, Inc.

  2. A facile one-step method for synthesising a parallelogram-shaped single-crystalline ZnO nanosheet

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Renyun, E-mail: renyun.zhang@miun.se; Hummelgård, Magnus; Olin, Håkan

    2014-05-01

    Graphical abstract: - Highlights: • A simple method to synthesise ZnO nanosheets is described. • Parallelogram-shaped ZnO nanosheets were obtained with single-crystalline structure. • A specific mechanism of the growth was suggested. - Abstract: ZnO nanosheets are found to be useful in many fields such as sensors and electronics. Non-uniform-shaped ZnO nanosheets are synthesised using several methods; moreover, uniformly shaped ones are less studied. Here, we report on a simple one-step method to synthesise parallelogram-shaped single-crystalline ZnO nanosheets. By controlling the reaction of Zn(NO{sub 3}){sub 2} and hexamethylenetetramine (HMT) in ethanol, average 30 nm-thick nanosheets with a high aspect ratio of 1:100 were obtained. The parallelogram angles were between 97° and 99°. Transmission electron microscopy (TEM) diffraction and X-ray diffraction (XRD) showed that the nanosheets were wurtzite-structured single-crystalline ZnO. Moreover, a growth mechanism of these parallelogram nanosheets is suggested based on the experimental results. These results suggest a new simple solution process to synthesise uniformly shaped ZnO nanosheets allowing large-scale production to be employed.

  3. Experimental study on effects of particle shape and operating conditions on combustion characteristics of single biomass particles

    DEFF Research Database (Denmark)

    Momenikouchaksaraei, Maryam; Yin, Chungen; Kær, Søren Knudsen

    2013-01-01

    An experimental study is performed to investigate the ignition, devolatilization, and burnout of single biomass particles of various shapes and sizes under process conditions that are similar to those in an industrial combustor. A charge-coupled device (CCD) camera is used to record the whole...

  4. Study on shaped single crystal growth and scintillating properties of Bi-doped rare-earth garnets

    Czech Academy of Sciences Publication Activity Database

    Novoselov, A.; Yoshikawa, A.; Nikl, Martin; Solovieva, Natalia; Fukuda, T.

    2005-01-01

    Roč. 40, 4/5 (2005), s. 419-423 ISSN 0232-1300 R&D Projects: GA MŠk(CZ) 1P04ME716 Institutional research plan: CEZ:AV0Z10100521 Keywords : garnet * shaped single crystal growth * luminescent properties * Bi 3+ Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 0.833, year: 2005

  5. Validation of single-plane fluoroscopy and 2D/3D shape-matching for quantifying shoulder complex kinematics.

    Science.gov (United States)

    Lawrence, Rebekah L; Ellingson, Arin M; Ludewig, Paula M

    2018-02-01

    Fluoroscopy and 2D/3D shape-matching has emerged as the standard for non-invasively quantifying kinematics. However, its accuracy has not been well established for the shoulder complex when using single-plane fluoroscopy. The purpose of this study was to determine the accuracy of single-plane fluoroscopy and 2D/3D shape-matching for quantifying full shoulder complex kinematics. Tantalum markers were implanted into the clavicle, humerus, and scapula of four cadaveric shoulders. Biplane radiographs were obtained with the shoulder in five humerothoracic elevation positions (arm at the side, 30°, 60°, 90°, maximum). Images from both systems were used to perform marker tracking, while only those images acquired with the primary fluoroscopy system were used to perform 2D/3D shape-matching. Kinematics errors due to shape-matching were calculated as the difference between marker tracking and 2D/3D shape-matching and expressed as root mean square (RMS) error, bias, and precision. Overall RMS errors for the glenohumeral joint ranged from 0.7 to 3.3° and 1.2 to 4.2 mm, while errors for the acromioclavicular joint ranged from 1.7 to 3.4°. Errors associated with shape-matching individual bones ranged from 1.2 to 3.2° for the humerus, 0.5 to 1.6° for the scapula, and 0.4 to 3.7° for the clavicle. The results of the study demonstrate that single-plane fluoroscopy and 2D/3D shape-matching can accurately quantify full shoulder complex kinematics in static positions. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  6. Comb-shaped single ion conductors based on polyacrylate ethers and lithium alkyl sulfonate

    International Nuclear Information System (INIS)

    Sun Xiaoguang; Hou Jun; Kerr, John B.

    2005-01-01

    Comb-shaped single ion conductors have been synthesized by (1) sulfonation of small molecule chloroethyleneglycols, which, after ion exchange to the Li + salt were then converted to the acrylate by reaction with acryloyl chloride and copolymerized with polyethylene glycol monomethyl ether acrylate (Mn = 454, n = 8) (PAE 8 -co-E 3 SO 3 Li); (2) sulfonation of chloride end groups grafted on to prepolymers of polyacrylate ethers (PAE 8 -g-E n SO 3 Li, n = 2, 3). The highest conductivity at 25 deg. C of 2.0 x 10 -7 S cm -1 was obtained for the PAE 8 -co-E 3 SO 3 Li with a salt concentration of EO/Li = 40. The conductivity of PAE 8 -g-E 3 SO 3 Li is lower than that of PAE 8 -co-E 3 SO 3 Li at similar salt concentrations, which is related to the incomplete sulfonation of the grafted polymer that leads to a lower concentration of Li + . The addition of 50 wt.% of plasticizer, PC/EMC (1/1, v/v), to PAE 8 -g-E 2 SO 3 Li increases the ambient conductivity by three orders of magnitude, which is due to the increased ion mobility in a micro-liquid environment and an increase concentration of free ions as a result of the higher dielectric constant of the solvent. A symmetrical Li/Li cell with an electrolyte membrane consisting of 75 wt.% PC/EMC (1/1, v/v) was cycled at a current density of 100 μA cm -2 at 85 deg. C. The cycling profile showed no concentration polarization after a break-in period during the first few cycles, which was apparently due to reaction of the solvent at the lithium metal surface that reacted with lithium metal to form a stable SEI layer

  7. Chick tooth induction revisited.

    Science.gov (United States)

    Cai, Jinglei; Cho, Sung-Won; Ishiyama, Mikio; Mikami, Masato; Hosoya, Akihiro; Kozawa, Yukishige; Ohshima, Hayato; Jung, Han-Sung

    2009-07-15

    Teeth have been missing from Aves for almost 100 million years. However, it is believed that the avian oral epithelium retains the molecular signaling required to induce odontogenesis, and this has been widely examined using heterospecific recombinations with mouse dental mesenchyme. It has also been argued that teeth can form from the avian oral epithelium owing to contamination of the mouse mesenchyme with mouse dental epithelial cells. To investigate the possibility of tooth formation from chick oral epithelium and the characteristics of possible chick enamel, we applied LacZ transgenic mice during heterospecific recombination and examined the further tooth formation. Transmission electron microscopy was used to identify the two tissues during development after heterospecific recombination. No mixing was detected between chick oral epithelium and mouse dental mesenchyme after 2 days, and secretory ameloblasts with Tomes' processes were observed after 1 week. Teeth were formed after 3 weeks with a single cusp pattern, possibly determined by epithelial factors, which is similar to that of the avian tooth in the late Jurassic period. These recombinant teeth were smaller than mouse molars, whereas perfect structures of both ameloblasts and enamel showed histological characteristics similar to those of mice. Together these observations consistent with previous report that odontogenesis is initially directed by species-specific mesenchymal signals interplaying with common epithelial signals. (c) 2009 Wiley-Liss, Inc.

  8. Investigation of hydrodynamics on local scour by shape of single spur dike in river bend

    International Nuclear Information System (INIS)

    Masjedi, A; Foroushani, E P

    2012-01-01

    A series of experiments were conducted in which the the scour hole associated with model spur dike was measured in a 180 degree laboratory flume bend under clear-water overtopping flows. In this study, the local scour were conducted for three different shapes of oblong, rectangulat chamfered of straight spur dikes at the bend with various Froude number. The main goals of the experiments were to evaluate the effect of the three different shapes of straight spur dikes on the volume of scour and potential aquatic habitat and on minimizing erosion adjacent to the streambanks. The experiments showed that of the three different shapes of straight spur dikes tested, the least erosion of the around in the near bank region was associated with the spur dikes with oblong shape, while the greatest volume of the scour hole was associated with the rectangular shape. So it was observed that, as Froude number increases, the scour increases.

  9. The effect of resorbable membranes on one-stage ridge augmentation in anterior single-tooth replacement: A randomized, controlled clinical trial.

    Science.gov (United States)

    Jonker, Brend P; Wolvius, Eppo B; van der Tas, Justin T; Pijpe, Justin

    2018-02-01

    To evaluate the effect of resorbable membranes on one-stage ridge augmentation procedures in small (2-4 mm) buccal bony dehiscences in anterior maxillary single-tooth replacement. Patients with a buccal bony dehiscence after implant placement in the esthetic zone were randomly allocated to one-stage ridge augmentation with (M+) or without a membrane (M-). Second-phase surgery was performed after 8 weeks, and follow-up was performed 1, 6, and ≥12 months after loading. Outcomes included implant survival and success, complications, clinical and radiographic parameters, esthetic results and patient satisfaction. Fifty-two patients were randomized to one-stage ridge augmentation with (n = 25) or without use of a membrane (n = 27). No significant differences in implant survival and success have been observed. The risk of having a small mucosal dehiscence was more than six times higher in the M+ group than in the M- group (RR 6.24, 95% CI 0.81 to 48.21). At the last follow-up, the bleeding index (BI) was marginally higher in the M+ group (14/9/2/0) compared to the M- group (24/2/0/0) (U = 205, Z = -2.97, p = .003, r = .42). The median change in marginal bone level was statistically lower in the M+ group (0.06 mm) than the M- group (0.60 mm) at last follow-up (U = 120, Z = -2.73 a p = .006 r = .42). Total pink esthetic index (PES) and white esthetic score (WES) and combined PES/WES were not significantly different between treatment groups at more than 12 months after loading. Only the subcategory root convexity/soft tissue color scored significantly lower in the M+ group (1.5) compared to the M- group (2.0) at the last follow-up (U = 172, Z = -2.34, p = .019 r = .34). No differences were found in patient satisfaction. The use of a resorbable membrane in small buccal bony dehiscences in anterior maxillary single-tooth replacement resulted in less marginal bone loss, but showed more mucosal dehiscences, higher bleeding scores and lower

  10. A 5- Year Comparison of Marginal Bone Level Following Immediate Loading of Single-Tooth Implants Placed in Healed Alveolar Ridges and Extraction Sockets in the Maxilla.

    Directory of Open Access Journals (Sweden)

    Antoine Nicolas Berberi

    2014-01-01

    Full Text Available AbstractPurpose: The aim of present investigation was to evaluate marginal bone level after 5-year follow-up of implants placed in healed ridges and fresh extraction sockets in maxilla with immediate loading protocol.Materials and Methods: Thirty-six patients in need of a single tooth replacement in the anterior maxilla received 42 Astra Tech implants (Astra Tech Implant system™, Dentsply Implants, Mölndal, Sweden. Implants were placed in healed ridges (group I or immediately into extraction sockets (group II. Implants were restored and placed into functional loading immediately by using a prefabricated abutment. Marginal bone level relative to the implant reference point was recorded at implant placement, crown cementation, 12, 36 and 60 months following loading using intra-oral radiographs. Measurements were made on the mesial and distal sides of each implantResults: Overall, two implants were lost from the group II, before final crown cementation: they were excluded from the study and all remaining implants osseointegrated successfully after 5 years of functional loading. The mean change in marginal bone loss after implant placement was 0.267±0.161 for one year, and 0.265±0.171 for three years and 0.213±0.185 for five years in extraction sockets and was 0.266±0.176 for one year and 0.219±0.175 for three years and 0.194±0.172 for five years in healed ridges group. Significant reduction of marginal bone loss was more pronounced in implants inserted in healed ridges (P

  11. Pre-fabricated zirconium dioxide implant abutments for single-tooth replacement in the posterior region: success and failure after 3 years of function.

    Science.gov (United States)

    Nothdurft, Frank P; Nonhoff, Joerg; Pospiech, Peter R

    2014-07-01

    Zirconia implant abutments have gained a much broader clinical use over the past few years. The aim of the present study was to assess the clinical performance of a pre-fabricated zirconium dioxide implant abutment for single-tooth replacement in the posterior region. Forty implants of the XiVE(®) S plus screw type (DENTSPLY Friadent, Mannheim, Germany) were inserted in the posterior region of 24 patients and provided with zirconium dioxide abutments (FRIADENT(®) CERCON(®) Abutment, DENTSPLY Friadent). The following parameters were used to document the state of soft tissue: modified plaque index, modified sulcus bleeding index and pocket depth. Mesial and distal bone levels were determined on radiographs during the prosthetic treatment and at the 36-month recall. Thirty-seven implants could be followed up after 36 months in function. One patient wearing two abutments was lost to follow-up. One abutment exhibited a rotational misfit after 2 years in function. A further abutment showed the same failure at the 36-months recall appointment. In the remaining 36 implants the soft and hard tissue parameters were indicative of a low inflammatory status. Compared to the baseline situation, a partly significant bone apposition could be observed. Chipping of parts of the veneering ceramic was registered in 22% of the remaining implant restorations. The use of zirconia abutments in this study lead to mainly healthy peri-implant hard and soft tissue conditions but, considering the observed failures after 3 years in function, clinical long-term results should be awaited before recommending full zirconia implant abutments in a posterior indication.

  12. Clinical evaluation of submerged and non-submerged implants for posterior single-tooth replacements: a randomized split-mouth clinical trial.

    Science.gov (United States)

    Nemli, S K; Güngör, M B; Aydın, C; Yılmaz, H; Türkcan, I; Demirköprülü, H

    2014-12-01

    The aim of this study was to evaluate clinical and radiographic results of submerged and non-submerged implants for posterior single-tooth replacements and to assess patient-based outcomes. Twenty patients were included in the study. A split-mouth design was used; implants inserted using a submerged technique were compared to those inserted with a non-submerged technique. Implants were restored with metal-ceramic crowns after 3 months. Reconstructions were examined at baseline, 6, 12, and 24 months. Standardized radiographs were made. Radiographic crestal bone level changes were calculated, as well as soft tissue parameters, including pocket probing depth, bleeding on probing, plaque index, and gingival index. Results were analyzed by two-way repeated measures of variance (ANOVA). To evaluate patient-based outcomes, patients were asked to complete a questionnaire at the 6-month follow-up; the Wilcoxon paired signed rank test was used to compare scores. The data of 18 patients were reviewed. During 24 months, non-submerged implants (0.57 ± 0.21 mm) showed significantly lower bone loss than submerged implants (0.68 ± 0.22 mm) (P<0.01). Patient satisfaction with non-submerged implants (median 87.5) was significantly higher than with submerged implants (median 81.5) (P<0.01). Non-submerged implants showed comparable clinical results to submerged implants and resulted in higher patient satisfaction due to decreased surgical intervention. Copyright © 2014 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  13. Influence of Laser-Lok surface on immediate functional loading of implants in single-tooth replacement: a 2-year prospective clinical study.

    Science.gov (United States)

    Farronato, Davide; Mangano, Francesco; Briguglio, Francesco; Iorio-Siciliano, Vincenzo; Riccitiello, Francesco; Guarnieri, Renzo

    2014-01-01

    The purpose of this study was to evaluate the influence of a Laser-Lok microtexturing surface on clinical attachment level and crestal bone remodeling around immediately functionally loaded implants in single-tooth replacement. Seventy-seven patients were included in a prospective, randomized study and divided into two groups. Group 1 (control) consisted of non-Laser-Lok type implants (n = 39), while in group 2 (test), Laser-Lok type implants were used (n = 39). Crestal bone loss (CBL) and clinical parameters including clinical attachment level (CAL), Plaque Index (PI), and bleeding on probing were recorded at baseline examinations and at 6, 12, and 24 months after loading with the final restoration. One implant was lost in the control group and one in the test group, giving a total survival rate of 96.1% after 2 years. PI and BOP outcomes were similar for both implant types without statistical differences. A mean CAL loss of 1.10 ± 0.51 mm was observed during the first 2 years in group 1, while the mean CAL loss observed in group 2 was 0.56 ± 0.33 mm. Radiographically, group 1 implants showed a mean crestal bone loss of 1.07 ± 0.30 mm compared with 0.49 ± 0.34 mm for group 2. The type of implant did not influence the survival rate, whereas Laser-Lok implants resulted in greater CAL and in shallower radiographic peri-implant CBL than non-Laser-Lok implants.

  14. Performance of zirconia abutments for implant-supported single-tooth crowns in esthetic areas: a retrospective study up to 12-year follow-up.

    Science.gov (United States)

    Passos, Sheila Pestana; Linke, Bernie; Larjava, Hannu; French, David

    2016-01-01

    The aim of this clinical study was to assess complications, success, and survival rates of zirconia abutments from different implant designs. Anterior implant-supported single-tooth restorations, after 1-12 years of clinical function, were evaluated. One hundred and fifty-eight zirconia implant abutments placed in 141 patients were evaluated. Mechanical complications were observed, such as presence or absence of abutment fractures and loss of retention. In addition, the peri-implant parameters were observed. Statistical analysis was performed using Fisher's exact tests, and bone level was analyzed using the nonparametric Mann-Whitney U-test for non-normally distributed data. Sixteen restorations exhibited different complications. However, no significant difference was observed between the standard and platform switching. The standard platforms exhibited higher marginal bone loss than platform switching design followed up to 5 years. Platform switching has a potentially higher risk of fracture in some designs. In our study, one standard platform as well as two-platform switch designs seem to withstand fracture in the anterior area, regardless of the implant width. Survival and success rates were 93.8% and 81.2% (up to >7 years ≤12), respectively, for standard platform; and 90 and 84% (up to >2 years ≤5), respectively, for platform switching. In general, standard platform implants restored with zirconia abutments were successful for the longest periods of observation and are a viable treatment alternative in anterior areas. Some of the studied designs of platform switching implants with zirconia abutments performed well for up to 5 years. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. A 5-year comparison of marginal bone level following immediate loading of single-tooth implants placed in healed alveolar ridges and extraction sockets in the maxilla

    Science.gov (United States)

    Berberi, Antoine N.; Sabbagh, Joseph M.; Aboushelib, Moustafa N.; Noujeim, Ziad F.; Salameh, Ziad A.

    2014-01-01

    Purpose: The aim of present investigation was to evaluate marginal bone level after 5-year follow-up of implants placed in healed ridges and fresh extraction sockets in maxilla with immediate loading protocol. Materials and Methods: Thirty-six patients in need of a single-tooth replacement in the anterior maxilla received 42 Astra Tech implants (Astra Tech Implant system™, Dentsply Implants, Mölndal, Sweden). Implants were placed either in healed ridges (group I) or immediately into fresh extraction sockets (group II). Implants were restored and placed into functional loading immediately by using a prefabricated abutment. Marginal bone level relative to the implant reference point was recorded at implant placement, crown cementation, 12, 36, and 60 months following loading using intra-oral radiographs. Measurements were made on the mesial and distal sides of each implant. Results: Overall, two implants were lost from the group II, before final crown cementation: they were excluded from the study. The mean change in marginal bone loss (MBL) after implant placement was 0.26 ± 0.161 mm for 1 year, and 0.26 ± 0.171 mm for 3 years, and 0.21 ± 0.185 mm for 5 years in extraction sockets and was 0.26 ± 0.176 mm for 1 year and 0.21 ± 0.175 mm for 3 years, and 0.19 ± 0.172 mm for 5 years in healed ridges group. Significant reduction of marginal bone was more pronounced in implants inserted in healed ridges (P implant after cementation of the provisional (P immediately loaded implants placed either in extraction sockets or healed ridges were similar. Functional loading technique by using prefabricated abutment placed during the surgery time seems to maintain marginal bone around implant in both healed and fresh extraction sites. PMID:24550840

  16. A 5-year comparison of marginal bone level following immediate loading of single-tooth implants placed in healed alveolar ridges and extraction sockets in the maxilla.

    Science.gov (United States)

    Berberi, Antoine N; Sabbagh, Joseph M; Aboushelib, Moustafa N; Noujeim, Ziad F; Salameh, Ziad A

    2014-01-01

    The aim of present investigation was to evaluate marginal bone level after 5-year follow-up of implants placed in healed ridges and fresh extraction sockets in maxilla with immediate loading protocol. Thirty-six patients in need of a single-tooth replacement in the anterior maxilla received 42 Astra Tech implants (Astra Tech Implant system™, Dentsply Implants, Mölndal, Sweden). Implants were placed either in healed ridges (group I) or immediately into fresh extraction sockets (group II). Implants were restored and placed into functional loading immediately by using a prefabricated abutment. Marginal bone level relative to the implant reference point was recorded at implant placement, crown cementation, 12, 36, and 60 months following loading using intra-oral radiographs. Measurements were made on the mesial and distal sides of each implant. Overall, two implants were lost from the group II, before final crown cementation: they were excluded from the study. The mean change in marginal bone loss (MBL) after implant placement was 0.26 ± 0.161 mm for 1 year, and 0.26 ± 0.171 mm for 3 years, and 0.21 ± 0.185 mm for 5 years in extraction sockets and was 0.26 ± 0.176 mm for 1 year and 0.21 ± 0.175 mm for 3 years, and 0.19 ± 0.172 mm for 5 years in healed ridges group. Significant reduction of marginal bone was more pronounced in implants inserted in healed ridges (P implant after cementation of the provisional (P immediately loaded implants placed either in extraction sockets or healed ridges were similar. Functional loading technique by using prefabricated abutment placed during the surgery time seems to maintain marginal bone around implant in both healed and fresh extraction sites.

  17. The shape of oxygen abundance profiles explored with MUSE: evidence for widespread deviations from single gradients

    Science.gov (United States)

    Sánchez-Menguiano, L.; Sánchez, S. F.; Pérez, I.; Ruiz-Lara, T.; Galbany, L.; Anderson, J. P.; Krühler, T.; Kuncarayakti, H.; Lyman, J. D.

    2018-02-01

    We characterised the oxygen abundance radial distribution of a sample of 102 spiral galaxies observed with VLT/MUSE using the O3N2 calibrator. The high spatial resolution of the data allowed us to detect 14345 H II regions with the same image quality as with photometric data, avoiding any dilution effect. We developed a new methodology to automatically fit the abundance radial profiles, finding that 55 galaxies of the sample exhibit a single negative gradient. The remaining 47 galaxies also display, as well as this negative trend, either an inner drop in the abundances (21), an outer flattening (10), or both (16), which suggests that these features are a common property of disc galaxies. The presence and depth of the inner drop depends on the stellar mass of the galaxies with the most massive systems presenting the deepest abundance drops, while there is no such dependence in the case of the outer flattening. We find that the inner drop appears always around 0.5 re, while the position of the outer flattening varies over a wide range of galactocentric distances. Regarding the main negative gradient, we find a characteristic slope in the sample of αO/H =-0.10 ± 0.03 dex /re. This slope is independent of the presence of bars and the density of the environment. However, when inner drops or outer flattenings are detected, slightly steeper gradients are observed. This suggests that radial motions might play an important role in shaping the abundance profiles. We define a new normalisation scale ("the abundance scale length", rO/H) for the radial profiles based on the characteristic abundance gradient, with which all the galaxies show a similar position for the inner drop ( 0.5 rO/H) and the outer flattening ( 1.5 rO/H). Finally, we find no significant dependence of the dispersion around the negative gradient with any property of the galaxies, with values compatible with the uncertainties associated with the derivation of the abundances.

  18. Single-tooth replacement in the anterior arch by means of a cantilevered IPS e.max Press veneer-retained fixed partial denture: case series of 35 patients.

    Science.gov (United States)

    Sun, Qiang; Chen, Lei; Tian, Lili; Xu, Baohua

    2013-01-01

    This case series study evaluated the clinical outcomes of cantilevered veneer-retained fixed partial dentures (VRFPDs) fabricated with IPS e.max Press for single-tooth replacement in the anterior arch. A total of 35 patients were treated with VRFPDs, including 17 cases in the maxilla and 18 in the mandible. The patients were evaluated at baseline and annually from October 2005 to July 2011 for the integrity of the VRFPDs, proximal contacts, occulsal relationships, pulp vitality, and tooth mobility. The degree of satisfaction was indicated with a visual analog scale. During a mean observation time of 46.57 months, 35 VRFPDs on vital abutment teeth did not exhibit postoperative sensitivity or secondary caries. No fractures or chipping of the restorations occurred within the course of the evaluation. No patient complained of food impaction. One cantilevered pontic needed adjustment on the incisal edge due to premature contacts after the 3-year recall examination. Cantilevered IPS e.max Press VRFPDs should be considered a minimally invasive, single-tooth restorative strategy in the anterior or first premolar area. Longer observation periods are necessary before this type of restorative design can be recommended as a general conservative procedure.

  19. Real-time Human Pose and Shape Estimation for Virtual Try-On Using a Single Commodity Depth Camera.

    Science.gov (United States)

    Ye, Mao; Wang, Huamin; Deng, Nianchen; Yang, Xubo; Yang, Ruigang

    2014-04-01

    We present a system that allows the user to virtually try on new clothes. It uses a single commodity depth camera to capture the user in 3D. Both the pose and the shape of the user are estimated with a novel real-time template-based approach that performs tracking and shape adaptation jointly. The result is then used to drive realistic cloth simulation, in which the synthesized clothes are overlayed on the input image. The main challenge is to handle missing data and pose ambiguities due to the monocular setup, which captures less than 50 percent of the full body. Our solution is to incorporate automatic shape adaptation and novel constraints in pose tracking. The effectiveness of our system is demonstrated with a number of examples.

  20. A segmentation and classification scheme for single tooth in MicroCT images based on 3D level set and k-means+.

    Science.gov (United States)

    Wang, Liansheng; Li, Shusheng; Chen, Rongzhen; Liu, Sze-Yu; Chen, Jyh-Cheng

    2017-04-01

    Accurate classification of different anatomical structures of teeth from medical images provides crucial information for the stress analysis in dentistry. Usually, the anatomical structures of teeth are manually labeled by experienced clinical doctors, which is time consuming. However, automatic segmentation and classification is a challenging task because the anatomical structures and surroundings of the tooth in medical images are rather complex. Therefore, in this paper, we propose an effective framework which is designed to segment the tooth with a Selective Binary and Gaussian Filtering Regularized Level Set (GFRLS) method improved by fully utilizing 3 dimensional (3D) information, and classify the tooth by employing unsupervised learning i.e., k-means++ method. In order to evaluate the proposed method, the experiments are conducted on the sufficient and extensive datasets of mandibular molars. The experimental results show that our method can achieve higher accuracy and robustness compared to other three clustering methods. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Functional design space of single-veined leaves: role of tissue hydraulic properties in constraining leaf size and shape.

    Science.gov (United States)

    Zwieniecki, Maciej A; Boyce, C Kevin; Holbrook, N Michele

    2004-10-01

    Morphological diversity of leaves is usually quantified with geometrical characters, while in many cases a simple set of biophysical parameters are involved in constraining size and shape. One of the main physiological functions of the leaf is transpiration and thus one can expect that leaf hydraulic parameters can be used to predict potential morphologies, although with the caveat that morphology in turn influences physiological parameters including light interception and boundary layer thickness and thereby heat transfer and net photosynthesis. An iterative model was used to determine the relative sizes and shapes that are functionally possible for single-veined leaves as defined by their ability to supply the entire leaf lamina with sufficient water to prevent stomatal closure. The model variables include the hydraulic resistances associated with vein axial and radial transport, as well as with water movement through the mesophyll and the leaf surface. The four parameters included in the model are sufficient to define a hydraulic functional design space that includes all single-veined leaf shapes found in nature, including scale-, awl- and needle-like morphologies. This exercise demonstrates that hydraulic parameters have dissimilar effects: surface resistance primarily affects leaf size, while radial and mesophyll resistances primarily affect leaf shape. These distinctions between hydraulic parameters, as well as the differential accessibility of different morphologies, might relate to the convergent evolutionary patterns seen in a variety of fossil lineages concerning overall morphology and anatomical detail that frequently have evolved in linear and simple multi-veined leaves.

  2. Precise predictions of H2O line shapes over a wide pressure range using simulations corrected by a single measurement

    Science.gov (United States)

    Ngo, N. H.; Nguyen, H. T.; Tran, H.

    2018-03-01

    In this work, we show that precise predictions of the shapes of H2O rovibrational lines broadened by N2, over a wide pressure range, can be made using simulations corrected by a single measurement. For that, we use the partially-correlated speed-dependent Keilson-Storer (pcsdKS) model whose parameters are deduced from molecular dynamics simulations and semi-classical calculations. This model takes into account the collision-induced velocity-changes effects, the speed dependences of the collisional line width and shift as well as the correlation between velocity and internal-state changes. For each considered transition, the model is corrected by using a parameter deduced from its broadening coefficient measured for a single pressure. The corrected-pcsdKS model is then used to simulate spectra for a wide pressure range. Direct comparisons of the corrected-pcsdKS calculated and measured spectra of 5 rovibrational lines of H2O for various pressures, from 0.1 to 1.2 atm, show very good agreements. Their maximum differences are in most cases well below 1%, much smaller than residuals obtained when fitting the measurements with the Voigt line shape. This shows that the present procedure can be used to predict H2O line shapes for various pressure conditions and thus the simulated spectra can be used to deduce the refined line-shape parameters to complete spectroscopic databases, in the absence of relevant experimental values.

  3. Determination and shaping of the ion-velocity distribution function in a single-ended Q machine

    DEFF Research Database (Denmark)

    Andersen, S.A.; Jensen, Vagn Orla; Michelsen, Poul

    1971-01-01

    An electrostatic energy analyzer with a resolution better than 0.03 eV was constructed. This analyzer was used to determine the ion-velocity distribution function at different densities and plate temperatures in a single-ended Q machine. In all regions good agreement with theoretical predictions...... based on simple, physical pictures is obtained. It is shown that within certain limits the velocity distribution function can be shaped; double-humped distribution functions have been obtained. The technique used here is suggested as an accurate method for determination of plasma densities within 10......% in single-ended Q machines...

  4. Single-Cell Optical Distortion Correction and Label-Free 3D Cell Shape Reconstruction on Lattices of Nanostructures.

    Science.gov (United States)

    Stephan, Jürgen; Keber, Felix; Stierle, Valentin; Rädler, Joachim O; Paulitschke, Philipp

    2017-12-13

    Imaging techniques can be compromised by aberrations. Especially when imaging through biological specimens, sample-induced distortions can limit localization accuracy. In particular, this phenomenon affects localization microscopy, traction force measurements, and single-particle tracking, which offer high-resolution insights into biological tissue. Here we present a method for quantifying and correcting the optical distortions induced by single, adherent, living cells. The technique uses periodically patterned gold nanostructures as a reference framework to quantify optically induced displacements with micrometer-scale sampling density and an accuracy of a few nanometers. The 3D cell shape and a simplified geometrical optics approach are then utilized to remap the microscope image. Our experiments reveal displacements of up to several hundred nanometers, and in corrected images these distortions are reduced by a factor of 3. Conversely, the relationship between cell shape and distortion provides a novel method of 3D cell shape reconstruction from a single image, enabling label-free 3D cell analysis.

  5. Coexistence of true talon cusp and double dens invaginatus in a single tooth: a rare case report and review of the literature.

    Science.gov (United States)

    Nu Nu Lwin, Hnin; Phyo Kyaw, Pyae; Wai Yan Myint Thu, Sai

    2017-12-01

    Co-occurrence of a talon cusp and double dens invaginatus is an extremely rare developmental dental anomaly. This case report represents a talon cusp with two dens invaginatus on a maxillary right lateral incisor. Early identification is needed for prevention of potential problems on the affected or opposing tooth.

  6. The effect of a tooth/tongue gel and mouthwash regimen on morning oral malodour : A 3-week single-blind randomized clinical trial

    NARCIS (Netherlands)

    van der Sluijs, E.; Van der Weijden, G.A.; Hennequin-Hoenderdos, N.L.; Slot, D.E.

    2018-01-01

    Aim: To compare the effects of a regimen consisting of a tooth/tongue gel, tongue cleaner and mouthwash with the effects of using standard fluoride dentifrice on the organoleptic oral malodour score (ORG) and volatile sulphur compounds (VSCs). Materials and methods: A total, 66 non-dental students

  7. Randomized-controlled clinical trial of customized zirconia and titanium implant abutments for single-tooth implants in canine and posterior regions: 3-year results.

    Science.gov (United States)

    Zembic, Anja; Sailer, Irena; Jung, Ronald Ernst; Hämmerle, Christoph Hans Franz

    2009-08-01

    The aim was to test whether or not zirconia abutments exhibit the same survival and technical/biological outcome as titanium abutments. Twenty-two patients receiving 40 single-tooth implants in canine and posterior regions were included. The implant sites were randomly assigned to 20 zirconia and 20 titanium abutments. All-ceramic and metal-ceramic crowns were fabricated. At baseline, 6, 12 and 36 months, the reconstructions were examined for technical and biological problems. Probing pocket depth (PPD), plaque control record (PCR) and bleeding on probing (BOP) were assessed at abutments (test) and analogous contralateral teeth (control). Standardized radiographs of the implants were made and the bone level (BL) was measured referring to the implant shoulder on mesial (mBL) and distal sides (dBL). The difference of color (DeltaE) of the peri-implant mucosa and the gingiva of control teeth was assessed with a spectrophotometer. The data were statistically analyzed with Mann-Whitney Rank and Student's unpaired t-tests. Eighteen patients with 18 zirconia and 10 titanium abutments were examined at a mean follow-up of 36 months (range 31.5-53.3 months). No fracture of an abutment or loss of a reconstruction was found. Hence, both exhibited 100% survival. At two metal-ceramic crowns supported by titanium abutments chipping of the veneering ceramic occurred. No difference of the biological outcome of zirconia and titanium abutments was observed: PPD (meanPPD(ZrO(2)) 3.2 +/- 1 mm, mPPD(Ti) 3.4 +/- 0.5 mm), PCR (mPCR(ZrO(2)) 0.1 +/- 0.2, mPCR(Ti) 0.1 +/- 0.2) and BOP (mBOP(ZrO(2)) 0.4 +/- 0.4, mBOP(Ti) 0.2 +/- 0.3). Furthermore, the BL was similar at implants supporting zirconia and titanium abutments (mBL(ZrO(2)) 1.7 +/- 1, dBL(ZrO(2)) 1.6 +/- 1; mBL(Ti) 2 +/- 1, dBL(Ti) 2.1 +/- 1). Both, zirconia and titanium abutments induced a similar amount of discoloration of the mucosa compared with the gingiva at natural teeth (DeltaE(ZrO(2)) 9.3 +/- 3.8, DeltaE(Ti) 6.8 +/- 3.8). At

  8. Performance of the Straumann Bone Level Implant system for anterior single-tooth replacements in augmented and nonaugmented sites: a prospective cohort study with 60 consecutive patients.

    Science.gov (United States)

    Santing, Hendrik J; Raghoebar, Gerry M; Vissink, Arjan; den Hartog, Laurens; Meijer, Henny J A

    2013-08-01

    The purpose of this prospective study was to evaluate radiographic, clinical and aesthetic outcomes and patient satisfaction of cases treated with platform-switched single implant restorations in the aesthetic region of the maxilla. Furthermore, the influence of an augmentation procedure 3 months before implant placement and the type of restoration (screw-retained vs. cement-retained) was evaluated. Sixty patients with a missing anterior tooth in the maxilla were treated with a Straumann Bone Level Implant. Bone augmentation was performed in 29 patients at 3 months before implant placement. Implants were loaded after 3 months of submerged healing. Follow-up was conducted at 7 and 18 months after implant placement. Peri-implant mucosa and implant crown aesthetic outcomes were determined using the Implant Crown Aesthetic Index (ICAI) and the Pink Esthetic Score-White Esthetic Score (PES-WES). No implants were lost. At 18 months after implant placement, mean bone level change was -0.10 ± 0.27 mm and mean probing pocket depth was 2.57 mm. No differences were found between augmented and nonaugmented sites (P = 0.28). The ICAI indicated satisfactory mucosa and crown aesthetics in 67% and 75% of the cases, respectively, while the PES score was 14.4. ICAI mucosa (P = 0.004) and PES (P = 0.02) scores were significantly less favourable for augmented sites compared with nonaugmented sites. Patient satisfaction was high (8.9 ± 1.1 on VAS-score). From the present prospective, clinical study, it can be concluded that the Straumann Bone Level Implant shows an excellent survival rate, marginal bone stability and good clinical and aesthetic results. Bone augmentation before implant placement does not lead to more marginal bone loss. However, less favourable pink aesthetic outcomes were found in augmented sites compared with nonaugmented sites, while no differences were found between cement-retained and screw-retained restorations. © 2012 John Wiley & Sons A/S.

  9. Influence of crystal–melt interface shape on self-seeding and single ...

    Indian Academy of Sciences (India)

    Many antimonide (Sb) crystals of 8 mm to 18 mm diameter were grown by optimized growth parameters. The forced convection and absence of conducting support to ampoule showed improvement in crystal quality of as grown ingots. Crystals showed preferred orientation and self-seeding. Results on interface shape and ...

  10. Influence of crystal–melt interface shape on self-seeding and single ...

    Indian Academy of Sciences (India)

    Unknown

    Abstract. The growth of Sb-based crystals (InSb, GaSb etc) was undertaken using resistive heater furnace by vertical directional solidification (VDS) technique. Crystal–melt interface shape during the growth was shown to convert from concave to convex along the crystal axis of the ingots. Many antimonide (Sb) crystals of 8 ...

  11. Fabrication of a membrane filter with controlled pore shape and its application to cell separation and strong single cell trapping

    International Nuclear Information System (INIS)

    Choi, Dong-Hoon; Yoon, Gun-Wook; Yoon, Jun-Bo; Park, Jeong Won; Lee, Dae-Sik; Ihm, Chunhwa

    2015-01-01

    A porous membrane filter is one of the key components for sample preparation in lab-on-a-chip applications. However, most of the membranes reported to date have only been used for size-based separation since it is difficult to provide functionality to the membrane or improve the performance of the membrane. In this work, as a method to functionalize the membrane filter, controlling the shape of the membrane pores is suggested, and a convenient and mass-producible fabrication method is provided. With the proposed method, membrane filters with round, conical and funnel shape pores were successfully fabricated, and we demonstrated that the sidewall slope of the conical shape pores could be precisely controlled. To verify that the membrane filter can be functionalized by controlled pore shape, we investigated filtration and trapping performance of the membrane filter with conical shape pores. In a filtration test of 1000 cancer cells (MCF-7, a breast cancer cell line) spiked in phosphate buffered saline (PBS) solution, 77% of the total cancer cells were retained on the membrane, and each cell from among 99.3% of the retained cells was automatically isolated in a single conical pore during the filtration process. Thanks to its engineered pore shape, trapping ability of the membrane with conical pores is dramatically improved. Microparticles trapped in the conical pores maintain their locations without any losses even at a more than 30 times faster external flow rate com-pared with those mounted on conventional cylindrical pores. Also, 78% of the cells trapped in the conical pores withstand an external flow of over 300 μl min −1 whereas only 18% of the cells trapped in the cylindrical pores remain on the membrane after 120 μl min −1 of an external flow is applied. (paper)

  12. A way of a single biomass particle shape characterization in a CFD model

    DEFF Research Database (Denmark)

    Trubetskaya, Anna; Beckmann, Gert; Jensen, Peter Arendt

    In this study, sieving, 2D imaging analysis (CAMSIZER/CAMSIZER XT) and optical microscopy were applied to the characterization of the size and shape of biomass particles. The 2D imaging technology was found to be the most convenient characterization method, providing information on the shape...... and external surface area of the particles. Different biomass samples were measured with an optical microscope and the results were compared with those from 2D imaging analysis. The main result of this study is that the data on particle width, measured by these two techniques, is identical. However......, for the particle length, measured by 2D imaging analysis, it is proposed to apply a correction factor equal to cos (45°). Based on the analysis of different biomass types, it is recommended to set the particle’s thickness to 2/3 of its width. In this study, a way to quantify all three dimensions of biomass...

  13. The two way shape memory effect: influence of stabilization in single and polycrystals of Cu-based alloys

    International Nuclear Information System (INIS)

    Cingolani, E.; Arneodo Larochette, P.; Ahlers, M.

    2000-01-01

    The possibility to obtain a two way shape memory effect (TWME) by stabilizing the martensite through diffusion controlled processes has been analysed in single and polycrystals of Cu-Zn-Al and in single crystals of Cu-Al-Be and Cu-Al-Ni. It is shown that the four systems behave very differently: Whereas in the Cu-Zn-Al single crystals sufficient vacancies remain available during extended times to obtain a perfect TWME, in Cu-Al-Be they anneal out fast, leading to a perfect TWME only right after quenching, and in Cu-Al-Ni they remain immobile below about 200 C. In polycrystals of Cu-Zn-Al the stabilization has only a negligible effect on the TWME, due to the formation of stable martensite configurations at the grain boundaries. (orig.)

  14. Multidimensional spectroscopy with a single broadband phase-shaped laser pulse

    International Nuclear Information System (INIS)

    Glenn, Rachel; Mukamel, Shaul

    2014-01-01

    We calculate the frequency-dispersed nonlinear transmission signal of a phase-shaped visible pulse to fourth order in the field. Two phase profiles, a phase-step and phase-pulse, are considered. Two dimensional signals obtained by varying the detected frequency and phase parameters are presented for a three electronic band model system. We demonstrate how two-photon and stimulated Raman resonances can be manipulated by the phase profile and sign, and selected quantum pathways can be suppressed

  15. Ni–Mn–Ga single crystal exhibiting multiple magnetic shape memory effects

    Czech Academy of Sciences Publication Activity Database

    Heczko, Oleg; Veřtát, Petr; Vronka, Marek; Kopecký, Vít; Perevertov, Oleksiy

    2016-01-01

    Roč. 2, č. 3 (2016), s. 272-280 ISSN 2199-384X R&D Projects: GA ČR GB14-36566G; GA ČR GA15-00262S Institutional support: RVO:68378271 Keywords : magnetic shape memory * NiMnGa * stress -strain * twinning * magnetic field-induced transformation * magnetic field-induced reorientation Subject RIV: BM - Solid Matter Physics ; Magnetism

  16. Immediate tooth replacement using fiber-reinforced composite and natural tooth pontic.

    Science.gov (United States)

    Kermanshah, Hamid; Motevasselian, Fariba

    2010-01-01

    The loss and replacement of anterior maxillary teeth poses several challenges. In patients refusing implant surgery, when minimal tooth reduction is desired, a fiber-reinforced composite fixed-partial denture may be used as a conservative alternative to a conventional fixed-partial denture for replacement of a single missing tooth. This article describes a clinical technique and six-year follow-up. The patient presented with a missing maxillary central incisor due to localized juvenile periodontitis. The abutment teeth were clinically stable. The advantage of supragingival margins and minimal tooth structure removal made the bonded bridge with a natural tooth pontic a viable procedure for this compromised restorative situation.

  17. Optimal piezoelectric beam shape for single and broadband vibration energy harvesting: Modeling, simulation and experimental results

    Science.gov (United States)

    Muthalif, Asan G. A.; Nordin, N. H. Diyana

    2015-03-01

    Harvesting energy from the surroundings has become a new trend in saving our environment. Among the established ones are solar panels, wind turbines and hydroelectric generators which have successfully grown in meeting the world's energy demand. However, for low powered electronic devices; especially when being placed in a remote area, micro scale energy harvesting is preferable. One of the popular methods is via vibration energy scavenging which converts mechanical energy (from vibration) to electrical energy by the effect of coupling between mechanical variables and electric or magnetic fields. As the voltage generated greatly depends on the geometry and size of the piezoelectric material, there is a need to define an optimum shape and configuration of the piezoelectric energy scavenger. In this research, mathematical derivations for unimorph piezoelectric energy harvester are presented. Simulation is done using MATLAB and COMSOL Multiphysics software to study the effect of varying the length and shape of the beam to the generated voltage. Experimental results comparing triangular and rectangular shaped piezoelectric beam are also presented.

  18. A High Energy and High Efficiency Spectral Shaping Single Frequency Fiber Laser Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR phase I project proposes a tunable single frequency high energy fiber laser system for coherent Lidar systems for remote sensing. Current state-of-art...

  19. A High Energy and High Efficiency Spectral Shaping Single Frequency Fiber Laser, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR phase II project proposes a single frequency high energy fiber laser system for coherent Lidar systems for remote sensing. Current state-of-art...

  20. A High Energy and High Efficiency Spectral Shaping Single Frequency Fiber Laser Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR phase II project proposes a single frequency high energy fiber laser system for coherent Lidar systems for remote sensing. Current state-of-art...

  1. A High Energy and High Efficiency Spectral Shaping Single Frequency Fiber Laser, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR phase I project proposes a tunable single frequency high energy fiber laser system for coherent Lidar systems for remote sensing. Current state-of-art...

  2. Effect of particle shape and structure on the results of single-particle light-scattering size analysis.

    Science.gov (United States)

    Umhauer, H; Bottlinger, M

    1991-11-20

    To evaluate quantitatively the influence exerted by the shape and structure of nonspherical, nonideal particles on the results of single-particle scattered-light size analysis, measurements were conducted with individual particles of different materials (glass, limestone, and quartz). For this purpose, the particles were suspended in an electrodynamic balance and repeatedly passed through the analyzer's measuring volume with a continually changing random orientation. The scattered-light signal spectra thus obtained specify the probability with which a certain pulse height is induced when the particle passes once through the measuring volume at a given coincidental orientation. The spectra reflect the material-characteristic influence. They allow the loss of resolution of common scattered-light size analyses to be assessed and algorithms (matrices) to be compiled with which the shape and structure influence may be mathematically eliminated. Because a shape and structure independent size parameter is also determined from the individual particles, exact calibration curves can be derived in which the shape and structure influence are incorporated.

  3. Overview of Tooth Disorders

    Science.gov (United States)

    ... necessitated by crowns and bridges. Bonding involves the attachment of tooth-colored fillings to natural teeth with ... Drugs Mentioned In This Article Generic Name Select Brand Names tetracycline ACHROMYCIN V Tooth Disorders Overview of ...

  4. Tooth - abnormal colors

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003065.htm Tooth - abnormal colors To use the sharing features on this page, please enable JavaScript. Abnormal tooth color is any color other than white to yellowish- ...

  5. Tooth Eruption without Roots

    OpenAIRE

    Wang, X.-P.

    2013-01-01

    Root development and tooth eruption are very important topics in dentistry. However, they remain among the less-studied and -understood subjects. Root development accompanies rapid tooth eruption, but roots are required for the movement of teeth into the oral cavity. It has been shown that the dental follicle and bone remodeling are essential for tooth eruption. So far, only limited genes have been associated with root formation and tooth eruption. This may be due to the diffic...

  6. Sensitive SERS detection at the single-particle level based on nanometer-separated mushroom-shaped plasmonic dimers

    Science.gov (United States)

    Xiang, Quan; Li, Zhiqin; Zheng, Mengjie; Liu, Qing; Chen, Yiqin; Yang, Lan; Jiang, Tian; Duan, Huigao

    2018-03-01

    Elevated metallic nanostructures with nanogaps (process to reliably define elevated nanometer-separated mushroom-shaped dimers directly from 3D resist patterns based on the gap-narrowing effect during the metallic film deposition. By controlling the initial size of nanogaps in resist structures and the following deposited film thickness, metallic nanogaps could be tuned at the sub-10 nm scale with single-digit nanometer precision. Both experimental and simulated results revealed that gold dimer on mushroom-shaped pillars have the capability to achieve higher SERS enhancement factor comparing to those plasmonic dimers on cylindrical pillars or on a common SiO2/Si substrate, implying that the nanometer-gapped elevated dimer is an ideal platform to achieve the highest possible field enhancement for various plasmonic applications.

  7. Orientation dependence of shape memory and super elastic effects in Ti-30% Ni-20% Cu single crystals

    International Nuclear Information System (INIS)

    Chumlyakov, Yu.I.; Kireeva, I.V.

    1999-01-01

    Single crystals of Ti-30% Ni-20% Cu (at.%) alloy experiencing B2-B19 martensitic transformation are used to study the dependence of deforming stress σ cr , shape memory effect and super elasticity on test temperature, crystal orientation and the sign of tension/compression stresses. It is shown that experimental values of shape memory effect and super elasticity as well as their dependences on orientation and loading regime are described within the frameworks of the model taking into account lattice distortions only. The orientation dependence and axial stress asymmetry in the temperature range of stress-induced martensite formation are determined by the dependence of lattice distortion during B2-B19 martensitic transformations on the orientation and the sign of applied stresses [ru

  8. Bunch-shape monitor for a picosecond single-bunch beam of a 35 MeV electron linear accelerator

    International Nuclear Information System (INIS)

    Hosono, Yoneichi; Nakazawa, Masaharu; Iguchi, Tetsuo

    1995-01-01

    A non-interactive-type bunch-shape and beam intensity monitor for a 35 MeV electron linear accelerator (linac) has been developed. The monitor consists of an electric SMA-type connector and an Al pipe of 50 mm inner diameter. Test measurements of the present monitor have been made under the conditions of the accelerated charges of lower than 27 nC/pulse and the pulse width ranging from 6 to 30 ps (Full Width at Half Maximum). The results show that the present monitor is applicable to bunch-shape measurement of the picosecond single-bunch beam. The monitor output is also found to be proportional to the beam intensity of more than 0.05 nC/pulse. (author)

  9. Multilobed mesiodens: a supernumerary tooth with unusual morphology.

    Science.gov (United States)

    Dave, Bhavna; Patel, Jalark; Swadas, Milan; Mallikarjuna, Rachappa

    2013-02-06

    An 8-year-old boy came with a chief complaint of an abnormally shaped tooth situated in upper front teeth region. On examination a supernumerary tooth with multiple lobes was present palatally to the maxillary right permanent central incisor. The morphology of the tooth crown was found to be unusual due to the presence of five lobes in the crown portion. Because of the supernumerary tooth, the permanent right central incisor was displaced labially. Radiographic examination showed a completely formed supernumerary tooth with dilacerated root. On the basis of clinical and radiographic examination, the supernumerary tooth was diagnosed as multilobed mesiodens. Since patient expressed dissatisfaction with the presence of supernumerary tooth, it was decided to extract this mesiodens followed by orthodontic treatment for alignment of labially placed maxillary right permanent central incisor.

  10. Minimizing the energy spread within a single bunch by shaping its charge distribution

    International Nuclear Information System (INIS)

    Loew, G.A.; Wang, J.W.

    1985-03-01

    It has been known for some time that partial compensation of the longitudinal wake field effects can be obtained for any bunch by placing it ahead of the accelerating crest (in space), thereby letting the positive rising sinusoidal field offset the negative beam loading field. The work presented in this paper shows that it is possible to obtain complete compensation, i.e., to reduce the energy spread essentially to zero by properly shaping the longitudinal charge distribution of the bunch and by placing it at the correct position on the wave. 3 refs., 5 figs., 3 tabs

  11. Single-shot color fringe projection for three-dimensional shape measurement of objects with discontinuities.

    Science.gov (United States)

    Dai, Meiling; Yang, Fujun; He, Xiaoyuan

    2012-04-20

    A simple but effective fringe projection profilometry is proposed to measure 3D shape by using one snapshot color sinusoidal fringe pattern. One color fringe pattern encoded with a sinusoidal fringe (as red component) and one uniform intensity pattern (as blue component) is projected by a digital video projector, and the deformed fringe pattern is recorded by a color CCD camera. The captured color fringe pattern is separated into its RGB components and division operation is applied to red and blue channels to reduce the variable reflection intensity. Shape information of the tested object is decoded by applying an arcsine algorithm on the normalized fringe pattern with subpixel resolution. In the case of fringe discontinuities caused by height steps, or spatially isolated surfaces, the separated blue component is binarized and used for correcting the phase demodulation. A simple and robust method is also introduced to compensate for nonlinear intensity response of the digital video projector. The experimental results demonstrate the validity of the proposed method.

  12. Shape-engineerable and highly densely packed single-walled carbon nanotubes and their application as super-capacitor electrodes.

    Science.gov (United States)

    Futaba, Don N; Hata, Kenji; Yamada, Takeo; Hiraoka, Tatsuki; Hayamizu, Yuhei; Kakudate, Yozo; Tanaike, Osamu; Hatori, Hiroaki; Yumura, Motoo; Iijima, Sumio

    2006-12-01

    We present a rational and general method to fabricate a high-densely packed and aligned single-walled carbon-nanotube (SWNT) material by using the zipping effect of liquids to draw tubes together. This bulk carbon-nanotube material retains the intrinsic properties of individual SWNTs, such as high surface area, flexibility and electrical conductivity. By controlling the fabrication process, it is possible to fabricate a wide range of solids in numerous shapes and structures. This dense SWNT material is advantageous for numerous applications, and here we demonstrate its use as flexible heaters as well as supercapacitor electrodes for compact energy-storage devices.

  13. Diode-pumped, single frequency Nd:YLF laser for 60-beam OMEGA laser pulse-shaping system

    International Nuclear Information System (INIS)

    Okishev, A.V.; Seka, W.

    1997-01-01

    The operational conditions of the OMEGA pulse-shaping system require an extremely reliable and low-maintenance master oscillator. The authors have developed a diode-pumped, single-frequency, pulsed Nd:YLF laser for this application. The laser generates Q-switched pulses of ∼160-ns duration and ∼10-microJ energy content at the 1,053-nm wavelength with low amplitude fluctuations (<0.6% rms) and low temporal jitter (<7 ns rms). Amplitude and frequency feedback stabilization systems have been used for high long-term amplitude and frequency stability

  14. Shape measurement system for single point incremental forming (SPIF) manufacts by using trinocular vision and random pattern

    International Nuclear Information System (INIS)

    Setti, Francesco; Bini, Ruggero; Lunardelli, Massimo; Bosetti, Paolo; Bruschi, Stefania; De Cecco, Mariolino

    2012-01-01

    Many contemporary works show the interest of the scientific community in measuring the shape of artefacts made by single point incremental forming. In this paper, we will present an algorithm able to detect feature points with a random pattern, check the compatibility of associations exploiting multi-stereo constraints and reject outliers and perform a 3D reconstruction by dense random patterns. The algorithm is suitable for a real-time application, in fact it needs just three images and a synchronous relatively fast processing. The proposed method has been tested on a simple geometry and results have been compared with a coordinate measurement machine acquisition. (paper)

  15. Stress analysis of martensitic transformation in Cu-Al-Be polycrystalline and single-crystalline shape memory alloy

    International Nuclear Information System (INIS)

    Kaouache, B.; Berveiller, S.; Inal, K.; Eberhardt, A.; Patoor, E.

    2003-01-01

    The aim of this study is to analyze the martensitic transformation in a shape memory alloy during a superelastic loading, focusing on internal strains, stresses and phases fractions. The behavior of the austenite phase is studied by X-ray diffraction stress analysis during in situ tensile test at room temperature. Both single-crystal and polycrystal samples have been investigated. The results are discussed with the aim to correlate the microstructural variations with the local stress state evolution in the austenitic phase while variants of martensite form and develop during a superelastic loading

  16. Nonlocal superelastic model of size-dependent hardening and dissipation in single crystal Cu-Al-Ni shape memory alloys.

    Science.gov (United States)

    Qiao, Lei; Rimoli, Julian J; Chen, Ying; Schuh, Christopher A; Radovitzky, Raul

    2011-02-25

    We propose a nonlocal continuum model to describe the size-dependent superelastic effect observed in recent experiments of single crystal Cu-Al-Ni shape memory alloys. The model introduces two length scales, one in the free energy and one in the dissipation, which account for the size-dependent hardening and dissipation in the loading and unloading response of micro- and nanopillars subject to compression tests. The information provided by the model suggests that the size dependence observed in the dissipation is likely to be associated with a nonuniform evolution of the distribution of the austenitic and martensitic phases during the loading cycle. © 2011 American Physical Society

  17. Influence of crystal–melt interface shape on self-seeding and single ...

    Indian Academy of Sciences (India)

    Unknown

    very important role on the crystal growth (single crystal growth). Further, temperature gradient is not employed on the crucible or ampoule wall in the aforementioned systems. However, it is considered on the external support, which holds the ampoule in heating furnace. In VDS technique. (Gadkari et al 1999a), this problem ...

  18. Single-Feature Polymorphism Discovery by Computing Probe Affinity Shape Powers

    Science.gov (United States)

    Single-feature polymorphism (SFP) discovery is a rapid and cost-effective approach for plant genomic polymorphism studies. However, either a high false positive rate or low sensitivity was reported in previous SFP detection methods. An alternative method was developed for genome-wide SFP discovery b...

  19. Detailed single-crystal EPR line shape measurements for the single-molecule magnets Fe8Br and Mn12-acetate

    Science.gov (United States)

    Hill, S.; Maccagnano, S.; Park, Kyungwha; Achey, R. M.; North, J. M.; Dalal, N. S.

    2002-06-01

    It is shown that our multi-high-frequency (40-200 GHz) resonant cavity technique yields distortion-free high-field electron paramagnetic resonance (EPR) spectra for single-crystal samples of the uniaxial and biaxial spin S=10 single-molecule magnets (SMM's) [Mn12O12(CH3COO)16(H2O)4].2CH3COOH.4H2O and [Fe8O2(OH)12(tacn)6]Br8.9H2O. The observed line shapes exhibit a pronounced dependence on temperature, magnetic field, and the spin quantum numbers (MS values) associated with the levels involved in the transitions. Measurements at many frequencies allow us to separate various contributions to the EPR linewidths, including significant D strain, g strain, and broadening due to the random dipolar fields of neighboring molecules. We also identify asymmetry in some of the EPR line shapes for Fe8 and a previously unobserved fine structure to some of the EPR lines for both the Fe8 and Mn12 systems. These findings prove relevant to the mechanism of quantum tunneling of magnetization in these SMM's.

  20. Detection of coincident radiations in a single transducer by pulse shape analysis

    Science.gov (United States)

    Warburton, William K [Menlo Park, CA

    2008-03-11

    Pulse shape analysis determines if two radiations are in coincidence. A transducer is provided that, when it absorbs the first radiation produces an output pulse that is characterized by a shorter time constant and whose area is nominally proportional to the energy of the absorbed first radiation and, when it absorbs the second radiation produces an output pulse that is characterized by a longer time constant and whose area is nominally proportional to the energy of the absorbed second radiation. When radiation is absorbed, the output pulse is detected and two integrals are formed, the first over a time period representative of the first time constant and the second over a time period representative of the second time constant. The values of the two integrals are examined to determine whether the first radiation, the second radiation, or both were absorbed in the transducer, the latter condition defining a coincident event.

  1. Size, shape, and diffusivity of a single Debye-Hückel polyelectrolyte chain in solution

    Science.gov (United States)

    Soysa, W. Chamath; Dünweg, B.; Prakash, J. Ravi

    2015-08-01

    Brownian dynamics simulations of a coarse-grained bead-spring chain model, with Debye-Hückel electrostatic interactions between the beads, are used to determine the root-mean-square end-to-end vector, the radius of gyration, and various shape functions (defined in terms of eigenvalues of the radius of gyration tensor) of a weakly charged polyelectrolyte chain in solution, in the limit of low polymer concentration. The long-time diffusivity is calculated from the mean square displacement of the centre of mass of the chain, with hydrodynamic interactions taken into account through the incorporation of the Rotne-Prager-Yamakawa tensor. Simulation results are interpreted in the light of the Odjik, Skolnick, Fixman, Khokhlov, and Khachaturian blob scaling theory (Everaers et al., Eur. Phys. J. E 8, 3 (2002)) which predicts that all solution properties are determined by just two scaling variables—the number of electrostatic blobs X and the reduced Debye screening length, Y. We identify three broad regimes, the ideal chain regime at small values of Y, the blob-pole regime at large values of Y, and the crossover regime at intermediate values of Y, within which the mean size, shape, and diffusivity exhibit characteristic behaviours. In particular, when simulation results are recast in terms of blob scaling variables, universal behaviour independent of the choice of bead-spring chain parameters, and the number of blobs X, is observed in the ideal chain regime and in much of the crossover regime, while the existence of logarithmic corrections to scaling in the blob-pole regime leads to non-universal behaviour.

  2. Tooth eruption without roots.

    Science.gov (United States)

    Wang, X-P

    2013-03-01

    Root development and tooth eruption are very important topics in dentistry. However, they remain among the less-studied and -understood subjects. Root development accompanies rapid tooth eruption, but roots are required for the movement of teeth into the oral cavity. It has been shown that the dental follicle and bone remodeling are essential for tooth eruption. So far, only limited genes have been associated with root formation and tooth eruption. This may be due to the difficulties in studying late stages of tooth development and tooth movement and the lack of good model systems. Transgenic mice with eruption problems and short or no roots can be used as a powerful model for further deciphering of the cellular, molecular, and genetic mechanisms underlying root formation and tooth eruption. Better understanding of these processes can provide hints on delivering more efficient dental therapies in the future.

  3. DNA Cross-Bridging Shapes a Single Nucleus from a Set of Mitotic Chromosomes.

    Science.gov (United States)

    Samwer, Matthias; Schneider, Maximilian W G; Hoefler, Rudolf; Schmalhorst, Philipp S; Jude, Julian G; Zuber, Johannes; Gerlich, Daniel W

    2017-08-24

    Eukaryotic cells store their chromosomes in a single nucleus. This is important to maintain genomic integrity, as chromosomes packaged into separate nuclei (micronuclei) are prone to massive DNA damage. During mitosis, higher eukaryotes disassemble their nucleus and release individualized chromosomes for segregation. How numerous chromosomes subsequently reform a single nucleus has remained unclear. Using image-based screening of human cells, we identified barrier-to-autointegration factor (BAF) as a key factor guiding membranes to form a single nucleus. Unexpectedly, nuclear assembly does not require BAF's association with inner nuclear membrane proteins but instead relies on BAF's ability to bridge distant DNA sites. Live-cell imaging and in vitro reconstitution showed that BAF enriches around the mitotic chromosome ensemble to induce a densely cross-bridged chromatin layer that is mechanically stiff and limits membranes to the surface. Our study reveals that BAF-mediated changes in chromosome mechanics underlie nuclear assembly with broad implications for proper genome function. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  4. Prediction of effects of punch shapes on tableting failure by using a multi-functional single-punch tablet press

    Directory of Open Access Journals (Sweden)

    Takashi Osamura

    2017-09-01

    Full Text Available We previously determined “Tableting properties” by using a multi-functional single-punch tablet press (GTP-1. We proposed plotting “Compactability” on the x-axis against “Manufacturability” on the y-axis to allow visual evaluation of “Tableting properties”. Various types of tableting failure occur in commercial drug production and are influenced by the amount of lubricant used and the shape of the punch. We used the GTP-1 to measure “Tableting properties” with different amounts of lubricant and compared the results with those of tableting on a commercial rotary tableting machine. Tablets compressed with a small amount of lubricant showed bad “Manufacturability”, leading to sticking of powder on punches. We also tested various punch shapes. The GTP-1 correctly predicted the actual tableting results for all punch shapes. With punches that were more likely to cause tableting failure, our system predicted the effects of lubricant quantity in the tablet formulation and the occurrence of sticking in the rotary tableting machine.

  5. Mixed-scale channel networks including Kingfisher-beak-shaped 3D microfunnels for efficient single particle entrapment

    Science.gov (United States)

    Lee, Yunjeong; Lim, Yeongjin; Shin, Heungjoo

    2016-06-01

    Reproducible research results for nanofluidics and their applications require viable fabrication technologies to produce nanochannels integrated with microchannels that can guide fluid flow and analytes into/out of the nanochannels. We present the simple fabrication of mixed-scale polydimethylsiloxane (PDMS) channel networks consisting of nanochannels and microchannels via a single molding process using a monolithic mixed-scale carbon mold. The monolithic carbon mold is fabricated by pyrolyzing a polymer mold patterned by photolithography. During pyrolysis, the polymer mold shrinks by ~90%, which enables nanosized carbon molds to be produced without a complex nanofabrication process. Because of the good adhesion between the polymer mold and the Si substrate, non-uniform volume reduction occurs during pyrolysis resulting in the formation of curved carbon mold side walls. These curved side walls and the relatively low surface energy of the mold provide efficient demolding of the PDMS channel networks. In addition, the trigonal prismatic shape of the polymer is converted into to a Kingfisher-beak-shaped carbon structure due to the non-uniform volume reduction. The transformation of this mold architecture produces a PDMS Kingfisher-beak-shaped 3D microfunnel that connects the microchannel and the nanochannel smoothly. The smooth reduction in the cross-sectional area of the 3D microfunnels enables efficient single microparticle trapping at the nanochannel entrance; this is beneficial for studies of cell transfection.Reproducible research results for nanofluidics and their applications require viable fabrication technologies to produce nanochannels integrated with microchannels that can guide fluid flow and analytes into/out of the nanochannels. We present the simple fabrication of mixed-scale polydimethylsiloxane (PDMS) channel networks consisting of nanochannels and microchannels via a single molding process using a monolithic mixed-scale carbon mold. The monolithic

  6. Study of magnetic field distribution in anisotropic single twin-boundary magnetic shape memory (MSM) element in actuators

    Science.gov (United States)

    Gabdullin, N.; Khan, S. H.

    2017-10-01

    Magnetic shape memory effect exhibited by certain alloys at room temperature is known for almost 20 years. The most studied MSM alloys are Ni-Mn-Ga alloys which exhibit up to 12% magnetic field-induced strain (change in shape) depending on microstructure. A multibillion cycle operation without malfunction along with their “smart” properties make them very promising for application in electromagnetic (EM) actuators and sensors. However, considerable twinning stress of MSM crystals resulting in magneto-mechanical hysteresis decreases the efficiency and output force of MSM actuators. Whereas twinning stress of conventional MSM crystals has been significantly decreased over the years, novel crystals with Type II twin boundaries (TBs) possess even lower twinning stress. Unfortunately, the microstructure of MSM crystals with very low twinning stress tends to be unstable leading to their rapid crack growth. Whilst this phenomenon has been studied experimentally, the magnetic field distribution in anisotropic single twin-boundary MSM elements has not been considered yet. This paper analyses the magnetic field distribution in two-variant single twin-boundary MSM elements and discusses its effects on magnetic field-induced stress acting on the twin boundary.

  7. Periodontal ligament injection versus routine local infiltration for nonsurgical single posterior maxillary permanent tooth extraction: comparative double-blinded randomized clinical study

    Directory of Open Access Journals (Sweden)

    Al-Shayyab MH

    2017-10-01

    Full Text Available Mohammad H Al-Shayyab Department of Oral and Maxillofacial Surgery, Oral Medicine and Periodontology, School of Dentistry, University of Jordan, Amman, Jordan Aim: The aim of this study was to evaluate the efficacy of, and patients’ subjective responses to, periodontal ligament (PDL anesthetic injection compared to traditional local-anesthetic infiltration injection for the nonsurgical extraction of one posterior maxillary permanent tooth. Materials and methods: All patients scheduled for nonsurgical symmetrical maxillary posterior permanent tooth extraction in the Department of Oral and Maxillofacial Surgery at the University of Jordan Hospital, Amman, Jordan over a 7-month period were invited to participate in this prospective randomized double-blinded split-mouth study. Every patient received the recommended volume of 2% lidocaine with 1:100,000 epinephrine for PDL injection on the experimental side and for local infiltration on the control side. A visual analog scale (VAS and verbal rating scale (VRS were used to describe pain felt during injection and extraction, respectively. Statistical significance was based on probability values <0.05 and measured using Χ2 and Student t-tests and nonparametric Mann–Whitney and Kruskal–Wallis tests. Results: Of the 73 patients eligible for this study, 55 met the inclusion criteria: 32 males and 23 females, with a mean age of 34.87±14.93 years. Differences in VAS scores and VRS data between the two techniques were statistically significant (P<0.001 and in favor of the infiltration injection. Conclusion: The PDL injection may not be the alternative anesthetic technique of choice to routine local infiltration for the nonsurgical extraction of one posterior maxillary permanent tooth. Keywords: PDL injection, infiltration, anesthesia, extraction

  8. Observation of martensitic structure evolution in Cu-Al-Ni single crystals with shape memory effect under external load using photoacoustic microscopy

    International Nuclear Information System (INIS)

    Muratikov, K.L.; Glazov, A.L.; Nikolaev, V.I.; Pul'nev, S.A.

    2006-01-01

    Photoacoustic microscopy is applied to observe the surface structure of Cu-Al-Ni shape-memory single crystals in both the loaded and unloaded states. Visualizing the early stages of the loading-induced martensitic transformation in Cu-Al-Ni single crystals is demonstrated to be feasible. The photoacoustic images are distinguished to advantage from the corresponding optical images by a higher contrast between different phases of the Cu-Al-Ni shape-memory alloy [ru

  9. Shape Optimization of the Assisted Bi-directional Glenn surgery for stage-1 single ventricle palliation

    Science.gov (United States)

    Verma, Aekaansh; Shang, Jessica; Esmaily-Moghadam, Mahdi; Wong, Kwai; Marsden, Alison

    2016-11-01

    Babies born with a single functional ventricle typically undergo three open-heart surgeries starting as neonates. The first of these stages (BT shunt or Norwood) has the highest mortality rates of the three, approaching 30%. Proceeding directly to a stage-2 Glenn surgery has historically demonstrated inadequate pulmonary flow (PF) & high mortality. Recently, the Assisted Bi-directional Glenn (ABG) was proposed as a promising means to achieve a stable physiology by assisting the PF via an 'ejector pump' from the systemic circulation. We present preliminary parametrization and optimization results for the ABG geometry, with the goal of increasing PF. To limit excessive pressure increases in the Superior Vena Cava (SVC), the SVC pressure is included as a constraint. We use 3-D finite element flow simulations coupled with a single ventricle lumped parameter network to evaluate PF & the pressure constraint. We employ a derivative free optimization method- the Surrogate Management Framework, in conjunction with the OpenDIEL framework to simulate multiple simultaneous evaluations. Results show that nozzle diameter is the most important design parameter affecting ABG performance. The application of these results to patient specific situations will be discussed. This work was supported by an NSF CAREER award (OCI1150184) and by the XSEDE National Computing Resource.

  10. Hyperspectral interferometry for single-shot absolute measurement of 3-D shape and displacement fields

    Directory of Open Access Journals (Sweden)

    Ruiz P. D.

    2010-06-01

    Full Text Available We propose a method that we call Hyperspectral Interferometry (HSI to resolve the 2π phase unwrapping problem in the analysis of interferograms recorded with a narrow-band light source. By using a broad-band light source and hyperspectral imaging system, a set of interferograms at different wavenumbers are recorded simultaneously on a high resolution image sensor. These are then assembled to form a three-dimensional intensity distribution. By Fourier transformation along the wavenumber axis, an absolute optical path difference is obtained for each pixel independently of the other pixels in the field of view. As a result, interferograms with spatially distinct regions are analysed as easily as continuous ones. The approach is illustrated with a HSI system to measure 3-D profiles of optically smooth or rough surfaces. Compared to existing profilometers able to measure absolute path differences, the single shot nature of the approach provides greater immunity from environmental disturbance.

  11. Dynamic optical arbitrary waveform shaping based on cascaded optical modulators of single FBG.

    Science.gov (United States)

    Chen, Jingyuan; Li, Peili

    2015-08-10

    A dynamic optical arbitrary waveform generation (O-AWG) with amplitude and phase independently controlled in optical modulators of single fiber Bragg Grating (FBG) has been proposed. This novel scheme consists of several optical modulators. In the optical modulator (O-MOD), a uniform FBG is used to filter spectral component of the input signal. The amplitude is controlled by fiber stretcher (FS) in Mach-Zehnder interference (MZI) structure through interference of two MZI arms. The phase is manipulated via the second FS in the optical modulator. This scheme is investigated by simulation. Consequently, optical pulse trains with different waveforms as well as pulse trains with nonuniform pulse intensity, pulse spacing and pulse width within each period are obtained through FSs adjustment to alter the phase shifts of signal in each O-MOD.

  12. Sorting of cells of the same size, shape, and cell cycle stage for a single cell level assay without staining

    Directory of Open Access Journals (Sweden)

    Yomo Tetsuya

    2006-06-01

    Full Text Available Abstract Background Single-cell level studies are being used increasingly to measure cell properties not directly observable in a cell population. High-performance data acquisition systems for such studies have, by necessity, developed in synchrony. However, improvements in sample purification techniques are also required to reveal new phenomena. Here we assessed a cell sorter as a sample-pretreatment tool for a single-cell level assay. A cell sorter is routinely used for selecting one type of cells from a heterogeneous mixture of cells using specific fluorescence labels. In this case, we wanted to select cells of exactly the same size, shape, and cell-cycle stage from a population, without using a specific fluorescence label. Results We used four light scatter parameters: the peak height and area of the forward scatter (FSheight and FSarea and side scatter (SSheight and SSarea. The rat pheochromocytoma PC12 cell line, a neuronal cell line, was used for all experiments. The living cells concentrated in the high FSarea and middle SSheight/SSarea fractions. Single cells without cell clumps were concentrated in the low SS and middle FS fractions, and in the higher FSheight/FSarea and SSheight/SSarea fractions. The cell populations from these viable, single-cell-rich fractions were divided into twelve subfractions based on their FSarea-SSarea profiles, for more detailed analysis. We found that SSarea was proportional to the cell volume and the FSarea correlated with cell roundness and elongation, as well as with the level of DNA in the cell. To test the method and to characterize the basic properties of the isolated single cells, sorted cells were cultured in separate wells. The cells in all subfractions survived, proliferated and differentiated normally, suggesting that there was no serious damage. The smallest, roundest, and smoothest cells had the highest viability. There was no correlation between proliferation and differentiation. NGF increases

  13. Management of crown root fracture in primary 'double tooth': a case report.

    Science.gov (United States)

    Tewari, Nitesh; Pandey, Ramesh Kumar; Jindal, Garima

    2011-02-01

    The term 'double tooth' is used to describe two developmental dental anomalies of shape: gemination and fusion. Traumatic episodes involving a fused or geminated primary tooth are rare. This report describes an unusual case of crown root fracture in a primary double tooth. © 2010 John Wiley & Sons A/S.

  14. CC-MUSIC: An Optimization Estimator for Mutual Coupling Correction of L-Shaped Nonuniform Array with Single Snapshot

    Directory of Open Access Journals (Sweden)

    Yuguan Hou

    2015-01-01

    Full Text Available For the case of the single snapshot, the integrated SNR gain could not be obtained without the multiple snapshots, which degrades the mutual coupling correction performance under the lower SNR case. In this paper, a Convex Chain MUSIC (CC-MUSIC algorithm is proposed for the mutual coupling correction of the L-shaped nonuniform array with single snapshot. It is an online self-calibration algorithm and does not require the prior knowledge of the correction matrix initialization and the calibration source with the known position. An optimization for the approximation between the no mutual coupling covariance matrix without the interpolated transformation and the covariance matrix with the mutual coupling and the interpolated transformation is derived. A global optimization problem is formed for the mutual coupling correction and the spatial spectrum estimation. Furthermore, the nonconvex optimization problem of this global optimization is transformed as a chain of the convex optimization, which is basically an alternating optimization routine. The simulation results demonstrate the effectiveness of the proposed method, which improve the resolution ability and the estimation accuracy of the multisources with the single snapshot.

  15. Experimental Study on Effects of Particle Shape and Operating Conditions on Combustion Characteristics of Single Biomass Particles

    DEFF Research Database (Denmark)

    Momeni, M.; Yin, Chungen; Kær, Søren Knudsen

    2013-01-01

    An experimental study is performed to investigate the ignition, devolatilization, and burnout of single biomass particles of various shapes and sizes under process conditions that are similar to those in an industrial combustor. A chargecoupled device (CCD) camera is used to record the whole...... combustion process. For the particles with similar volume (mass), cylindrical particles are found to lose mass faster than spherical particles and the burnout time is shortened by increasing the particle aspect ratio (surface area). The conversion times of cylindrical particles with almost the same surface...... area/volume ratio are very close to each other. The ignition, devolatilization, and burnout times of cylindrical particles are also affected by the oxidizer temperature and oxygen concentration, in which the oxygen concentration is found to have a more pronounced effect on the conversion times at lower...

  16. The crystalline quality distribution in CdZnTe single crystal correlated to the interface shape during growth

    Energy Technology Data Exchange (ETDEWEB)

    Azoulay, M.; Rotter, S.; Gafni, G. (Soreq Nuclear Research Center, Yavne (Israel)); Roth, M. (School of Applied Science and Technology, Hebrew Univ. of Jerusalem (Israel))

    1992-02-01

    Crystalline quality of CdZnTe single crystals grown by the vertical gradient freeze (VGF) method has been evaluated using the double crystal rocking curve (DCRC) analysis and etch pits density (EPD) measurements. The full width at half maximum (HWHM) values of the DCRCs vary within 40% while the EPD values range from 2 to 8 x 10{sup 4} cm{sup -2} along the crystal growth axis. Best results are obtained for the central part of the crystals, where the growth interface exhibits a nearly planar shape. The results obtained have been used for practical implications with regard to the use of CdZnTe crystals as a substrate material for HgCdTe thin films growth. (orig.).

  17. Seed-mediated shape evolution of gold nanomaterials: from spherical nanoparticles to polycrystalline nanochains and single-crystalline nanowires

    International Nuclear Information System (INIS)

    Qiu Penghe; Mao Chuanbin

    2009-01-01

    We studied the kinetics of the reduction of a gold precursor (HAuCl 4 ) and the effect of the molar ratio (R) of sodium citrate, which was introduced from a seed solution, and the gold precursor on the shape evolution of gold nanomaterials in the presence of preformed 13 nm gold nanoparticles as seeds. The reduction of the gold precursor by sodium citrate was accelerated due to the presence of gold seeds. Nearly single-crystalline gold nanowires were formed at a very low R value (R = 0.16) in the presence of the seeds as a result of the oriented attachment of the growing gold nanoparticles. At a higher R value (R = 0.33), gold nanochains were formed due to the non-oriented attachment of gold nanoparticles. At a much higher R value (R = 1.32), only larger spherical gold nanoparticles grown from the seeds were found. In the absence of gold seeds, no single-crystalline nanowires were formed at the same R value. Our results indicate that the formation of the 1D nanostructures (nanochains and nanowires) at low R values is due to the attachment of gold nanoparticles along one direction, which is driven by the surface energy reduction, nanoparticle attraction, and dipole-dipole interaction between adjacent nanoparticles.

  18. Cavities/Tooth Decay

    Science.gov (United States)

    ... a process that occurs over time. Here's how tooth decay develops: Plaque forms. Dental plaque is a clear sticky film that coats ... by a lack of saliva, which helps prevent tooth decay by washing away food and plaque from your teeth. Substances found in saliva also help counter the ...

  19. All-ceramic single-tooth implant reconstructions using modified zirconia abutments: a prospective randomized controlled clinical trial of the effect of pink veneering ceramic on the esthetic outcomes.

    Science.gov (United States)

    Büchi, Dominik L E; Sailer, Irena; Fehmer, Vincent; Hämmerle, Christoph H F; Thoma, Daniel S

    2014-01-01

    The aim of this study was to test whether veneering of the submucosal part of zirconia abutments using pink veneering ceramic positively influences the color of the peri-implant mucosa. Single-tooth implants were restored with either white zirconia abutments (control group) or pink-veneered zirconia abutments and all-ceramic crowns. Esthetic outcome measurements included a spectrophotometric evaluation of the peri-implant mucosal color. Test and control groups induced a visible discoloration of the peri-implant mucosa after the insertion of the abutments and following cementation of the crowns compared to natural teeth. The calculated color differences were above the clinically visible threshold value and were more favorable for the control group, although not statistically significant. It is concluded that veneering of zirconia abutments with pink veneering ceramic failed to positively influence the esthetic outcome, mostly due to a decrease of the brightness compared with the control group.

  20. An Up-to-15-Year Comparison of the Survival and Complication Burden of Three-Unit Tooth-Supported Fixed Dental Prostheses and Implant-Supported Single Crowns.

    Science.gov (United States)

    Walton, Terry R

    2015-01-01

    To assess and compare the outcomes and economic complication burden of three-unit tooth-supported fixed dental prostheses (TFDPs) and implant-supported single crowns (ISCs) provided to a sequential cohort in a specialist prosthodontic practice over a 15-year period. Sequential patients requiring replacement of a single missing tooth between 1996 and 2010 with a metal-ceramic three-unit TFDP (n = 145 patients, n = 174 prostheses) or ISC (n = 174 patients, n = 220 prostheses) were included. Prostheses subjectively judged at insertion to have an unfavorable 10-year prognosis (17 TFDPs, 0 ISCs) were removed from statistical analyses. The estimated cumulative survival (ECS) was calculated with the life table actuarial method and standard errors calculated with the Greenwood formula. Differences in outcomes between all prostheses and those replacing only anterior or only posterior teeth were assessed with the log rank test. Complication incidence, severity, and economic burden, measured in time/cost accounting units (TAUs), were tallied and compared descriptively. The 15-year ECS did not differ for 112 TFDPs (92.75% ± 3.28%) and 81 ISCs (95.95% ± 2.92%) replacing posterior teeth. However, the 15-year ECS was significantly greater for 139 ISCs (93.33% ± 6.44%) than for 45 TFDPs (82.82% ± 6.50%) replacing anterior teeth. The economic burden of nonterminal complications for both prostheses was low (mean = 0.3 and 0.2 TAUs per prosthesis for TFDPs and ISCs, respectively). This equated to 3 TAUs/100 years in clinical service and 4 TAUs/100 years in clinical service for the TFDPs and ISCs, respectively. The survival of three-unit TFDPs and ISCs over 15 years was not statistically different when replacing posterior teeth, but ISCs survived significantly better when replacing anterior teeth. The complication rates of the TFDPs and ISCs were similar, but the economic burden for the TFDPs was greater.

  1. Flow-through PCR on a 3D qiandu-shaped polydimethylsiloxane (PDMS) microdevice employing a single heater: toward microscale multiplex PCR.

    Science.gov (United States)

    Wu, Wenming; Loan, Kieu The Loan; Lee, Nae Yoon

    2012-05-07

    Consistent temperature control in an on-chip flow-through polymerase chain reaction (PCR) employing two or more heaters is one of the main obstacles for device miniaturization and integration when realizing micro total analysis systems (μTAS), and also leads to operational complexity. In this study, we propose a qiandu (right triangular prism)-shaped polydimethylsiloxane (PDMS) microdevice with serpentine microchannels fabricated on its slanted plane, and apply the device for an on-chip flow-through PCR employing a single heater. The inclined nature of the qiandu-shaped microdevice enables the formation of a surface temperature gradient along the slanted plane of the microdevice in a height-dependent manner by the use of a single heater, and enables liquid to traverse over wide ranges of temperatures, including the three temperature zones--denaturation, annealing, and extension temperatures--required in a typical PCR. The feasibility of the qiandu-shaped PDMS microdevice as a versatile platform for performing a flow-through PCR was examined by employing multiple templates and varying the inclination angle of the device. In addition, the potential of performing a multiplex PCR using a single qiandu-shaped PDMS microdevice was explored. A 409 bp long gene fragment effective as a marker for diagnosing lung cancer and a 230 bp long gene fragment from a plasmid vector were simultaneously amplified in less than 25 min on a single microdevice, paving the way for a microscale, multiplex PCR on a single device employing a single heater.

  2. [Mechanisms of tooth eruption].

    Science.gov (United States)

    Maltha, J C

    2014-04-01

    Tooth eruption is of the utmost importance for the normal development of the dentition and the face. Since the 1980s, it has been known that the tooth germ itself is not essential for facilitating the processes that make tooth eruption possible. For that reason, recent research on the regulatory mechanisms of tooth eruption has focused mainly on the enamel organ and the dental follicle. Different regulatory mechanisms act on the occlusal and the apical sides of an erupting tooth. On the occlusal side osteoclast differentiation is stimulated. This leads to the development of an eruption canal, a process in which macrophages and matrix metalloproteases also play an important role. On the apical side the most important factors are the transcription factor RUNX2 and the bone morphogenic protein 2. They are responsible for the deposition of trabecular bone in that area. Many regulatory mechanisms which are involved in tooth eruption are also active in other developmental processes. This explains that certain syndromes can also have an effect on the tooth eruption process.

  3. Parameters influencing the fatigue life of a Cu–Al–Be single-crystal shape memory alloy under repeated bending

    International Nuclear Information System (INIS)

    Siredey-Schwaller, N; Eberhardt, A; Bastie, P

    2009-01-01

    One of the principal limitations in the use of shape memory alloys is certainly fatigue behaviour. Initially, the mechanical behaviour of polycrystals evolves during cycling and then rupture occurs after a relatively small number of cycles, in particular for deformation higher than a few per cent. If one replaces the polycrystal by a single crystal, one notices an important increase in the fatigue lifespan, mainly for high deformation (Siredey et al 2005 Mater. Sci. Eng. A 396 296–301). The aim of this study is to analyse the role of three parameters influencing the lifespan in mechanical fatigue. The first one relates to the atmosphere in which the test is carried out. No notable influence was found. However, for samples having spent 44 000 h in air, one notes a lifespan reduction for those tested in the presence of air, whereas it is normal for those tested under argon. In the second part, the effect of the surface state will be discussed. As already presented in Siredey et al (2005 Mater. Sci. Eng. A 396 296–301), surface roughness influences lifespan, especially for low imposed strain. However, for higher strain this effect is much less important. On the surface, striations due to martensitic transformations appear during cycling. However, the damage inside these striations seems not to be correlated to rupture. The third parameter relates to crystalline quality of the single crystal. It was studied with a hard x-ray diffractometer using a transposition at high energy of the Guinier–Tennevin method. Crystalline quality is found to play a crucial role in the lifespan in fatigue. The presence of sub-grains disoriented by about 1° and mosaicity can reduce the lifespan by a factor up to 10

  4. Functional constraints on tooth morphology in carnivorous mammals

    Directory of Open Access Journals (Sweden)

    Smits Peter D

    2012-08-01

    Full Text Available Abstract Background The range of potential morphologies resulting from evolution is limited by complex interacting processes, ranging from development to function. Quantifying these interactions is important for understanding adaptation and convergent evolution. Using three-dimensional reconstructions of carnivoran and dasyuromorph tooth rows, we compared statistical models of the relationship between tooth row shape and the opposing tooth row, a static feature, as well as measures of mandibular motion during chewing (occlusion, which are kinetic features. This is a new approach to quantifying functional integration because we use measures of movement and displacement, such as the amount the mandible translates laterally during occlusion, as opposed to conventional morphological measures, such as mandible length and geometric landmarks. By sampling two distantly related groups of ecologically similar mammals, we study carnivorous mammals in general rather than a specific group of mammals. Results Statistical model comparisons demonstrate that the best performing models always include some measure of mandibular motion, indicating that functional and statistical models of tooth shape as purely a function of the opposing tooth row are too simple and that increased model complexity provides a better understanding of tooth form. The predictors of the best performing models always included the opposing tooth row shape and a relative linear measure of mandibular motion. Conclusions Our results provide quantitative support of long-standing hypotheses of tooth row shape as being influenced by mandibular motion in addition to the opposing tooth row. Additionally, this study illustrates the utility and necessity of including kinetic features in analyses of morphological integration.

  5. Feasibility of immediate placement of single-tooth implants in the aesthetic zone: a 1-year randomized controlled trial.

    Science.gov (United States)

    Slagter, Kirsten W; Meijer, Henny J A; Bakker, Nicolaas A; Vissink, Arjan; Raghoebar, Gerry M

    2015-06-26

    To assess whether outcome of immediate implant placement and immediate provisionalization after 1 year was non-inferior to immediate implant placement and delayed provisionalization regarding Marginal Bone Level (MBL). Forty patients with a failing tooth in the aesthetic zone were randomly assigned for immediate implant placement with immediate (n = 20) or delayed (n = 20) provisionalization. Follow-up was at 1 month and after 1 year. The study was powered to detect a difference in MBL of implant parameters, aesthetic indexes and patient satisfaction were assessed. After 1 year, MBL changes were -0.75 ± 0.69 mesially and -0.68 ± 0.65 distally mm for the immediate group and -0.70 ± 0.64 and -0.68 ± 0.64 mm for the delayed group respectively (NS). Regarding differences in means, non-inferiority was observed after 1 year (mesially: Group A versus B: difference in mean 0.08 mm (95% CI -0.38 to 0.53, p = 0.71 distally: Group A versus B: difference in mean 0.09 mm (95% CI -0.37 to 0.56 mm, p = 0.66).No significant differences in the other outcome variables were observed. This study showed that immediate placement and immediate provisionalization was non-inferior to immediate placement with delayed provisionalization. In addition, although not powered for these outcome variables, no clinically relevant differences in other outcomes were observed (www.isrtcn.com: ISRCTN57251089). © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Imaging with a single-element forward-looking steerable IVUS catheter using optical shape sensing (Conference Presentation)

    Science.gov (United States)

    Janjic, Jovana; Mastik, Frits; Leistikow, Merel; Bosch, Johannes G.; van der Steen, Antonius F. W.; van Soest, Gijs

    2017-03-01

    Complex intravascular lesions, such as chronic total occlusions (CTOs), require forward-looking imaging. We propose to use a 25 MHz single-element transducer and an optical shape sensing (OSS) fiber integrated into a steerable catheter to achieve intravascular imaging in a forward-looking approach. A tissue-mimicking phantom with three hollow channels (3, 2 and 1 mm in diameter) and two steel spheres (1.5 mm in diameter) is used as imaging target. Ultrasound data and OSS data are simultaneously acquired while steering and rotating a 8.5 F catheter with bidirectional tip flexion. The obtained ultrasound data are reconstructed in 3D space using the position and direction information from the OSS data. Afterwards, the sparsely sampled ultrasound data are projected on a 2D plane and interpolated using normalized convolution (NC), which has been shown previously to perform well on irregularly sampled data [1]. The front surface of the phantom together with the location of two of the three channels and the two steel spheres are successfully reconstructed. The ability to reconstruct different components and their location in space is very important during CTOs crossing. This type of information can aid the crossing procedure providing insights about the best entry point, such as channels location, and helping in avoiding highly calcified areas, which usually are displayed in ultrasound imaging as highly scattering regions.

  7. Shaping Ability of Reciproc, WaveOne GOLD, and HyFlex EDM Single-file Systems in Simulated S-shaped Canals.

    Science.gov (United States)

    Özyürek, Taha; Yılmaz, Koray; Uslu, Gülşah

    2017-05-01

    The aim of the present study was to compare the shaping ability of Reciproc (RPC; VDW, Munich, Germany), HyFlex EDM (HEDM; Coltene/Whaledent AG, Altstätten, Switzerland), and WaveOne GOLD (WOG; Dentsply Maillefer, Ballaigues, Switzerland) nickel-titanium (NiTi) files made of different NiTi alloys in S-shaped simulated canals. Sixty S-shaped canals in resin blocks were prepared to an apical size of 0.25 mm using RPC R25, WOG Primary, and HEDM OneFile (n = 20 canal/per group) systems. Composite images were made from the superimposition of pre- and postinstrumentation images. The amount of resin removed by each system was measured using a digital template and image analysis software in 22 different points. Canal aberrations were also recorded. Data were statistically analyzed using the Kruskal-Wallis and post hoc Dunn tests at the 5% level. NiTi file fracture was not observed during shaping of the simulated canals although a danger zone formation in 1 sample and a ledge in 1 sample were observed in the RPC group. There was no statistically significant difference between the WOG and HEDM groups' apical, medial, and coronal regions (P > .05). However, it was determined that the RPC group removed a statistically significantly higher amount of resin from all the canal regions when compared with the WOG and HEDM groups (P < .05). Within the limitation of the present study, it was determined that all of the tested NiTi files caused various levels of resin removal. However, WOG and HEDM NiTi files were found to cause a lower level of resin removal than RPC NiTi files. Copyright © 2017 American Association of Endodontists. All rights reserved.

  8. Advances and perspectives in tooth tissue engineering.

    Science.gov (United States)

    Monteiro, Nelson; Yelick, Pamela C

    2017-09-01

    Bio-engineered teeth that can grow and remodel in a manner similar to that of natural teeth have the potential to serve as permanent replacements to the currently used prosthetic teeth, such as dental implants. A major challenge in designing functional bio-engineered teeth is to mimic both the structural and anisotropic mechanical characteristics of the native tooth. Therefore, the field of dental and whole tooth regeneration has advanced towards the molecular and nanoscale design of bio-active, biomimetic systems, using biomaterials, drug delivery systems and stem cells. The focus of this review is to discuss recent advances in tooth tissue engineering, using biomimetic scaffolds that provide proper architectural cues, exhibit the capacity to support dental stem cell proliferation and differentiation and sequester and release bio-active agents, such as growth factors and nucleic acids, in a spatiotemporal controlled manner. Although many in vitro and in vivo studies on tooth regeneration appear promising, before tooth tissue engineering becomes a reality for humans, additional research is needed to perfect methods that use adult human dental stem cells, as opposed to embryonic dental stem cells, and to devise the means to generate bio-engineered teeth of predetermined size and shape. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  9. Replacing a Missing Tooth

    Science.gov (United States)

    ... there are two options for replacement: First, a removable partial denture may be used to replace the missing tooth. ... appearance look and feel more natural than a removable partial denture. However, it does require grinding down the support ...

  10. To Tell the Tooth

    Science.gov (United States)

    ... a Sparkling Smile Holiday Workshop Thanksgiving Back to School Fourth of July Fun Tooth Fairy Sugar Wars Valentine's Day Halloween Defeat Monster Mouth! Color and Count Puzzle Fun Oral Health Made Easy ...

  11. The cracked tooth.

    Science.gov (United States)

    Zuckerman, G R

    1998-01-01

    Fractured molars and premolars are very common. Fractures usually result from cracks that develop and slowly extend until the tooth separates into buccal and lingual fragments. Sometimes, as these cracks expand, the patient exhibits symptoms of what is commonly referred to as "cracked tooth syndrome" (CTS). When CTS occurs, an opportunity exists to diagnose and treat these patients, to relieve their discomfort and prevent sequelae that would require more extensive treatment.

  12. Immediate placement or immediate restoration/loading of single implants for molar tooth replacement: a systematic review and meta-analysis.

    Science.gov (United States)

    Atieh, Momen A; Payne, Alan G T; Duncan, Warwick J; de Silva, Rohana K; Cullinan, Mary P

    2010-01-01

    This systematic review and meta-analysis assessed the survival of immediately placed single implants in fresh molar extraction sites and immediately restored/loaded single molar implants in healed molar sites. A search of the main electronic databases, including the Cochrane Oral Health Group's Trials Register, was conducted up to November 1, 2008. The meta-analysis was prepared in accordance with the guidelines of the Academy of Osseointegration Workshop on the State of the Science on Implant Dentistry. The data were analyzed with statistical software. For immediately placed molar implants, nine studies describing 1,013 implants were included to support a survival rate of 99.0%. There were no significant differences between immediate and delayed loading/restoration in molar sites (relative risk of 0.30, 95% confidence interval 0.05 to 1.61; P = .16). For immediate restoration/loading of single implants in healed molar sites, seven studies with 188 single implants were identified. In this case, the implant survival rate was 97.9%, with no difference between immediate and delayed loading (relative risk of 3.0, 95% confidence interval: 0.33 to 27.16; P = .33). Favorable marginal bone level changes in the immediate loading group were detected at 12 months (mean difference of -0.31, 95% confidence interval: -0.53 to -0.096; P = .005). The protocols of immediate placement and immediate restoration/loading of single implants in mandibular molar regions showed encouraging results.

  13. A windowing and mapping strategy for gear tooth fault detection of a planetary gearbox

    Science.gov (United States)

    Liang, Xihui; Zuo, Ming J.; Liu, Libin

    2016-12-01

    When there is a single cracked tooth in a planet gear, the cracked tooth is enmeshed for very short time duration in comparison to the total time of a full revolution of the planet gear. The fault symptom generated by the single cracked tooth may be very weak. This study aims to develop a windowing and mapping strategy to interpret the vibration signal of a planetary gear at the tooth level. The fault symptoms generated by a single cracked tooth of the planet gear of interest can be extracted. The health condition of the planet gear can be assessed by comparing the differences among the signals of all teeth of the planet gear. The proposed windowing and mapping strategy is tested with both simulated vibration signals and experimental vibration signals. The tooth signals can be successfully decomposed and a single tooth fault on a planet gear can be effectively detected.

  14. Shaped single crystal grow and scintillation properties of Bi:GD.sub.3./sub.Ga.sub.5./sub.O.sub.12./sub..

    Czech Academy of Sciences Publication Activity Database

    Novoselov, A.; Yoshikawa, A.; Nikl, Martin; Solovieva, Natalia; Fukuda, T.

    2005-01-01

    Roč. 537, - (2005), s. 247-250 ISSN 0168-9002 R&D Projects: GA AV ČR(CZ) KSK1010104 Institutional research plan: CEZ:AV0Z10100521 Keywords : garnet * shaped single crystal grow * luminescent properties * Bi 3+ Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.224, year: 2005

  15. Restoration of the endodontically treated posterior tooth

    Directory of Open Access Journals (Sweden)

    Andrea Polesel

    2014-06-01

    Results and conclusions: Direct adhesive restorations, indirect bonded restorations and traditional full crown are three therapeutic options for the single posterior endodontically treated teeth. The amount of remaining sound tooth structure is the most significant factor influencing the therapeutic approach. The clinician's operative skill is a determining aspect for long-term success of adhesive inlays.

  16. Performance of the Straumann Bone Level Implant system for anterior single-tooth replacements in augmented and nonaugmented sites : A prospective cohort study with 60 consecutive patients

    NARCIS (Netherlands)

    Santing, Hendrik J.; Raghoebar, Gerry M.; Vissink, Arjan; den Hartog, Laurens; Meijer, Henny J. A.

    Aim The purpose of this prospective study was to evaluate radiographic, clinical and aesthetic outcomes and patient satisfaction of cases treated with platform-switched single implant restorations in the aesthetic region of the maxilla. Furthermore, the influence of an augmentation procedure 3months

  17. A New Design of a Single-Device 3D Hall Sensor: Cross-Shaped 3D Hall Sensor

    Directory of Open Access Journals (Sweden)

    Wei Tang

    2018-04-01

    Full Text Available In this paper, a new single-device three-dimensional (3D Hall sensor called a cross-shaped 3D Hall device is designed based on the five-contact vertical Hall device. Some of the device parameters are based on 0.18 μm BCDliteTM technology provided by GLOBALFOUNDRIES. Two-dimensional (2D and 3D finite element models implemented in COMSOL are applied to understand the device behavior under a constant magnetic field. Besides this, the influence of the sensing contacts, active region’s depth, and P-type layers are taken into account by analyzing the distribution of the voltage along the top edge and the current density inside the devices. Due to the short-circuiting effect, the sensing contacts lead to degradation in sensitivities. The P-type layers and a deeper active region in turn are responsible for the improvement of sensitivities. To distinguish the P-type layer from the active region which plays the dominant role in reducing the short-circuiting effect, the current-related sensitivity of the top edge (Stop is defined. It is found that the short-circuiting effect fades as the depth of the active region grows. Despite the P-type layers, the behavior changes a little. When the depth of the active region is 7 μm and the thickness of the P-type layers is 3 μm, the sensitivities in the x, y, and z directions can reach 91.70 V/AT, 92.36 V/AT, and 87.10 V/AT, respectively.

  18. Use of short implants (6 mm) in a single-tooth replacement: a 5-year follow-up prospective randomized controlled multicenter clinical study.

    Science.gov (United States)

    Rossi, Fabio; Botticelli, Daniele; Cesaretti, Gianfranco; De Santis, Enzo; Storelli, Stefano; Lang, Niklaus P

    2016-04-01

    To evaluate prospectively clinical and radiographic outcomes of 6- or 10 mm-long implants with moderately rough surface (SLA(®) ) loaded within 7 weeks from installation and supporting single crowns in the posterior regions in the course of 5 years of loading. Sixty implants with a moderately rough surface, 30 tests (6 mm long, 4.1 mm in diameter) and 30 controls (10 mm long, 4.1 mm in diameter), were placed in posterior regions in 45 patients. After 6 weeks, impressions were taken and the implants were restored with a single fixed prosthesis made with gold-palladium alloy and porcelain. Survival rate and marginal bone loss were evaluated yearly. The clinical crown/implant ratio was calculated. During the follow-up period, five implants, four tests and one control, were lost. Of the four test implants, one was lost before loading, two between the 2nd and the 3rd years, and one during the 4th year of the follow-up period. The control implant was lost during the first year of function. Consequently, after 5 years of follow-up, a survival rate of 86.7% and 96.7% was observed at the test and control sites, respectively. The results of this study showed that 6-mm-long implants supporting single crowns loaded within 7 weeks from installation lose a small amount of marginal bone during 5 years of functional loading, similar to that of 10-mm-long implants. However, a higher degree of implant loss was recorded at the short implants, probably due to the fracturing of the surrounding bone. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. The effect of internal and external stress on two-way shape-memory behaviour in Co49Ni21.6Ga29.4 single crystals

    International Nuclear Information System (INIS)

    Liu, G D; Dai, X F; Luo, H Z; Liu, H Y; Meng, F B; Li, Y; Yu, X; Chen, J L; Wu, G H

    2011-01-01

    The effect of the internal stress on the two-way shape memory in Co 49 Ni 21.6 Ga 29.4 single crystals has been investigated. We found that the internal stress generated natively by the solidifying process works as a tensile force along the growth direction. Applying different compressive pre-stresses along the [0 0 1] direction, the shape-memory strain can be continuously changed from +1.0% to -2.3%. In the [1 1 0] direction, the strain monotonically increases from -2.0% to -4.0% due to a strong detwinning produced by the consistent effect of the external and internal stresses.

  20. Signatures for shape-phase transitions in the rare-earth nuclei, in the evolution of single-particle spectra and two-particle transfer-intensities

    Energy Technology Data Exchange (ETDEWEB)

    Fossion, R. [Instituto de Ciencias Nucleares, UNAM, Apartado Postal 70-543, 04510 Mexico D. F. (Mexico)

    2008-12-15

    The rare-earth Nd, Sm, Gd and Dy nuclei are well known to undergo a shape-phase transition around N {approx} 90 from vibrational to rotational behaviour - or, correspondingly - from a spherical nuclear shape to an axial-symmetric deformed shape. This can experimentally be verified by, for example, the evolution of the R{sub 4/2} = E(4{sup +}{sub 1})/E(2{sup +}{sub 1}) ratio, or the evolution of the quadrupole moment, Q{sub 2}. Recently, the study o nuclear phase-shape transitions has gained considerable interest, since the introduction of exact algebraic solutions for the critical points many of the different phase-shape transitions that are possible in the atomic nucleus. In this contribution, in the first part, we investigate the microscopic underlying mechanism that drives the rare-earth isotopes towards deformation, studying the evolution of their proton an neutron single-particle spectra within the Relativistic Hartree-Bogoliubov model. In the second part, within the Interacting Boson Model and the framework with boson coherent states, and in the light of renewed interest in experiments on two-particle transfer-reactions, we study the evolution of the transfer spectroscopic intensities as a possible signature of shape-phase transitions. (Author)

  1. Biomaterial Selection for Tooth Regeneration

    Science.gov (United States)

    Yuan, Zhenglin; Nie, Hemin; Wang, Shuang; Lee, Chang Hun; Li, Ang; Fu, Susan Y.; Zhou, Hong

    2011-01-01

    Biomaterials are native or synthetic polymers that act as carriers for drug delivery or scaffolds for tissue regeneration. When implanted in vivo, biomaterials should be nontoxic and exert intended functions. For tooth regeneration, biomaterials have primarily served as a scaffold for (1) transplanted stem cells and/or (2) recruitment of endogenous stem cells. This article critically synthesizes our knowledge of biomaterial use in tooth regeneration, including the selection of native and/or synthetic polymers, three-dimensional scaffold fabrication, stem cell transplantation, and stem cell homing. A tooth is a complex biological organ. Tooth loss represents the most common organ failure. Tooth regeneration encompasses not only regrowth of an entire tooth as an organ, but also biological restoration of individual components of the tooth including enamel, dentin, cementum, or dental pulp. Regeneration of tooth root represents perhaps more near-term opportunities than the regeneration of the whole tooth. In the adult, a tooth owes its biological vitality, arguably more, to the root than the crown. Biomaterials are indispensible for the regeneration of tooth root, tooth crown, dental pulp, or an entire tooth. PMID:21699433

  2. Fatigue resistance and failure mode of novel-design anterior single-tooth implant restorations: influence of material selection for type III veneers bonded to zirconia abutments.

    Science.gov (United States)

    Magne, Pascal; Paranhos, Maria Paula Gandolfi; Burnett, Luiz Henrique; Magne, Michel; Belser, Urs Christoph

    2011-02-01

    This study assessed the fatigue resistance and failure mode of type III porcelain and composite resin veneers bonded to custom zirconia implant abutments. Twenty-four standardized zirconia implant abutments were fabricated. Using the CEREC 3 machine, type III veneers of standardized shape were milled in ceramic Vita Mark II or in composite resin Paradigm MZ100. The intaglio surfaces of the restorations were hydrofluoric acid etched and silanated (Mark II) or airborne-particle abraded and silanated (MZ100). The fitting surface of the abutments was airborne-particle abraded, cleaned, and inserted into a bone level implant (BLI RC SLActive 10 mm). All veneers (n=24) were adhesively luted with a zirconia primer (Z-Prime Plus), adhesive resin (Optibond FL) and a pre-heated light-curing composite resin (Filtek Z100). Cyclic isometric chewing (5 Hz) was simulated, starting with a load of 40 N, followed by stages of 80, 120, 160, 200, 240, and 280 N (20,000 cycles each). Samples were loaded until fracture or to a maximum of 140,000 cycles. Groups were compared using the life table survival analysis (Logrank test at P=.05). Mark II and MZ100 specimens fractured at an average load of 216 N and 229 N (survival rate of 17% and 8%), respectively, with no difference in survival probability (P=.18). Among the fractured samples, 40% of the failures were at the abutment level for Mark II and 27% were at the abutment level for MZ100. No exclusive adhesive failures were observed. Type III Mark II and Paradigm MZ100 veneers showed similar fatigue resistance when bonded to custom non-retentive zirconia implant abutments. The bond was strong enough to induce abutment fractures. MZ100 presented a higher percentage of "friendly" failures, i.e. maintaining the restoration-abutment adhesive interface and the abutment itself intact. © 2010 John Wiley & Sons A/S.

  3. Mechanical Control of Whole Body Shape by a Single Cuticular Protein Obstructor-E in Drosophila melanogaster.

    Directory of Open Access Journals (Sweden)

    Reiko Tajiri

    2017-01-01

    Full Text Available Body shapes are much more variable than body plans. One way to alter body shapes independently of body plans would be to mechanically deform bodies. To what extent body shapes are regulated physically, or molecules involved in physical control of morphogenesis, remain elusive. During fly metamorphosis, the cuticle (exoskeleton covering the larval body contracts longitudinally and expands laterally to become the ellipsoidal pupal case (puparium. Here we show that Drosophila melanogaster Obstructor-E (Obst-E is a protein constituent of the larval cuticle that confers the oriented contractility/expandability. In the absence of obst-E function, the larval cuticle fails to undergo metamorphic shape change and finally becomes a twiggy puparium. We present results indicating that Obst-E regulates the arrangement of chitin, a long-chain polysaccharide and a central component of the insect cuticle, and directs the formation of supracellular ridges on the larval cuticle. We further show that Obst-E is locally required for the oriented shape change of the cuticle during metamorphosis, which is associated with changes in the morphology of those ridges. Thus, Obst-E dramatically affects the body shape in a direct, physical manner by controlling the mechanical property of the exoskeleton.

  4. Immediate Placement and Occlusal Loading of Single-Tooth Restorations on Partially Threaded, Titanium-Tantalum Combined Dental Implants: 1-Year Results.

    Science.gov (United States)

    Peron, Cristian; Romanos, Georgios

    2016-01-01

    Single nonrestorable teeth were atraumatically extracted and hybrid titanium implants with tantalum-based midsections (TM) were placed in fresh extraction sockets. Provisional acrylic crowns were delivered (in occlusion) immediately after surgery. Occlusal contacts were present in the maximal intercuspation but not in the lateral movements of the mandible. Two weeks after placement, the implants were finally restored with screw-retained or cemented lithium disilicate crowns. A total of 25 patients were treated (26 implants). Most implants were placed in maxillary premolar locations and in lower-density bone. Mean crestal bone loss was 0.58 ± 0.34 mm. Implant survival and success rates were 100%, respectively (follow-up: 14.1 ± 1.5 months). Within the limitations of this study, immediate placement and loading of TM implants resulted in predictable clinical, functional, and esthetic outcomes.

  5. Potential oscillations and S-shaped polarization curve in the continuous electro-oxidation of CO on platinum single-crystal electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Koper, Marc T.M.; Schmidt, Thomas J.; Markovic, Nenad M.; Ross, Philip N.

    2001-03-01

    The occurrence of an S-shaped polarization curve in a simple model for the continuous electrochemical oxidation of CO on a platinum electrode is discussed. In the model, the S-shaped polarization curve is caused by the competitive Langmuir-Hinshelwood mechanism between surface-bonded CO and OH. The reaction is studied experimentally on single-crystal platinum rotating disk electrodes in perchloric and sulfuric acid solution, and it is shown that the voltammetry is in good agreement with the model predictions. When studied under current-controlled conditions, a fast galvanodynamic scan indeed suggests the existence of the S-shaped polarization curve. At lower scan rates, however, irregularities and small-amplitude irregular fluctuations or oscillations in potential are observed. Very regular potential oscillations under current-controlled conditions are observed only on Pt(111) in sulfuric acid. The possible origin of these irregularities and oscillations is discussed in relation to the existing theories of electrochemical instabilities.

  6. Computed tomography to quantify tooth abrasion

    Science.gov (United States)

    Kofmehl, Lukas; Schulz, Georg; Deyhle, Hans; Filippi, Andreas; Hotz, Gerhard; Berndt-Dagassan, Dorothea; Kramis, Simon; Beckmann, Felix; Müller, Bert

    2010-09-01

    Cone-beam computed tomography, also termed digital volume tomography, has become a standard technique in dentistry, allowing for fast 3D jaw imaging including denture at moderate spatial resolution. More detailed X-ray images of restricted volumes for post-mortem studies in dental anthropology are obtained by means of micro computed tomography. The present study evaluates the impact of the pipe smoking wear on teeth morphology comparing the abraded tooth with its contra-lateral counterpart. A set of 60 teeth, loose or anchored in the jaw, from 12 dentitions have been analyzed. After the two contra-lateral teeth were scanned, one dataset has been mirrored before the two datasets were registered using affine and rigid registration algorithms. Rigid registration provides three translational and three rotational parameters to maximize the overlap of two rigid bodies. For the affine registration, three scaling factors are incorporated. Within the present investigation, affine and rigid registrations yield comparable values. The restriction to the six parameters of the rigid registration is not a limitation. The differences in size and shape between the tooth and its contra-lateral counterpart generally exhibit only a few percent in the non-abraded volume, validating that the contralateral tooth is a reasonable approximation to quantify, for example, the volume loss as the result of long-term clay pipe smoking. Therefore, this approach allows quantifying the impact of the pipe abrasion on the internal tooth morphology including root canal, dentin, and enamel volumes.

  7. Single-Tooth Replacement Using Dental Implants Supporting All-Ceramic and Metal-Based Reconstructions: Results at 18 Months of Loading.

    Science.gov (United States)

    Bösch, Adrian; Jung, Ronald Ernst; Sailer, Irena; Goran, Benic; Hämmerle, Christoph Hans; Thoma, Daniel Stefan

    The aim of this study was to compare customized zirconia and titanium abutments with respect to survival rates and technical, biologic, and esthetic outcomes. A total of 28 patients with single implants were randomly assigned to 12 customized zirconia (test, AC) and 16 customized titanium (control, MC) abutments. Technical, biologic, and esthetic outcomes were assessed after a mean follow-up time of 18 months. No biologic complications were observed, and no statistical difference for the bone-to-implant distance was found at 18 months (AC -0.05 ± 0.51 mm vs MC -0.28 ± 0.77 mm; P = .40). A similar discoloration of the peri-implant mucosa was observed (ΔE AC 9.6 ± 5.4, ΔE MC 7.6 ± 5.3; P = .46). The mean papilla score values evaluation presented no statistically significant differences between the test and control groups (AC 2.07 ± 0.94, MC 1.96 ± 0.84). At 18 months, reconstructions based on zirconia and titanium abutments exhibited similar survival rates and similar clinical outcomes.

  8. The cracked tooth syndrome.

    Science.gov (United States)

    Lynch, Christoper D; McConnell, Robert J

    2002-09-01

    The purpose of this article is to review the clinical features, diagnosis and management of the cracked tooth syndrome (CTS). The condition refers to an incomplete fracture of a vital posterior tooth that occasionally extends into the pulp. A lack of awareness of the condition coupled with its varied clinical features can make diagnosis of CTS difficult. Common symptoms include an uncomfortable sensation or pain from a tooth that occurs while chewing hard foods and which ceases when the pressure is withdrawn. The patient is often unable to identify the offending tooth or quadrant involved, and may report a history of numerous dental procedures with unsatisfactory results. Successful diagnosis and management requires an awareness of the existence of CTS and the appropriate diagnostic tests. Management options depend on the nature of the symptoms and extent of the lesion. These options include routine monitoring, occlusal adjustments, placement of a cast restoration and endodontic treatment. A decision flowchart indicating the treatment options available to the dental practitioner is presented.

  9. Quantitative molecular and culture analyses of bacterial elimination in oval-shaped root canals by a single-file instrumentation technique.

    Science.gov (United States)

    Alves, F R F; Rôças, I N; Almeida, B M; Neves, M A S; Zoffoli, J; Siqueira, J F

    2012-09-01

    Bacterial reduction in oval-shaped root canals by a single-instrument technique was compared ex vivo with a conventional nickel-titanium rotary technique. Data obtained from two quantification methods, quantitative real-time polymerase chain reaction (qPCR) and culture, were also compared. Oval-shaped canals of extracted teeth contaminated with Enterococcus faecalis were instrumented using either a single Reciproc instrument or the BioRaCe instrument series. Bacteriological samples were taken before (S1) and after instrumentation (S2). Bacterial quantification was performed using qPCR and culture. Intragroup analysis showed that both protocols promoted a highly significant bacterial reduction (P 0.05). As for the quantification methods, qPCR revealed significantly higher counts of E. faecalis in S1 than culture (P 0.05). The single-file technique was comparable with the conventional technique in oval-shaped canals provided the width of apical preparation, volume of irrigants and duration of irrigation are kept similar. No significant difference was observed for qPCR and culture in post-instrumentation samples, indicating that both methods can be reliably used for studies of antibacterial effectiveness. © 2012 International Endodontic Journal.

  10. Dentition and tooth replacement pattern in Chalcides (Squamata; Scincidae).

    Science.gov (United States)

    Delgado, Sidney; Davit-Beal, Tiphaine; Sire, Jean-Yves

    2003-05-01

    This study was undertaken as a prerequisite to investigations on tooth differentiation in a squamate, the Canarian scincid Chalcides. Our main goal was to determine whether the pattern of tooth replacement, known to be regular in lizards, could be helpful to predict accurately any stage of tooth development. A growth series of 20 laboratory-reared specimens, aged from 0.5 month after birth to about 6 years, was used. The dentition (functional and replacement teeth) was studied from radiographs of jaw quadrants. The number of tooth positions, the tooth number in relation to age and to seasons, and the size of the replacement teeth were recorded. In Chalcides, a single row of pleurodont functional teeth lies at the labial margin of the dentary, premaxillary, and maxillary. Whatever the age of the specimens, 16 tooth positions were recorded, on average, in each quadrant, suggesting that positions are maintained throughout life. Replacement teeth were numerous whatever the age and season, while the number of functional teeth was subject to variation. Symmetry of tooth development was evaluated by comparing teeth two by two from the opposite side in the four jaw quadrants of several specimens. Although the relative size of some replacement teeth fitted perfectly, the symmetry criterion was not reliable to predict the developmental stage of the opposite tooth, whether the pair of teeth compared was left-right or upper-lower. The best fit was found when comparing the size of successive replacement teeth from the front to the back of the jaw. Every replacement tooth that is 40-80% of its definitive size is followed, in the next position on the arcade, by a tooth that is, on average, 20% less developed. Considering teeth in alternate positions (even and odd series), each replacement tooth was a little more developed than the previous, more anterior, one (0.5-20% when the teeth are from 10-40% of their final size). The latter pattern showed that tooth replacement occurred in

  11. Mesiodistal tooth angulation to segmental occlusal plane in panoramic radiography

    International Nuclear Information System (INIS)

    Kim, Jae Duk; Kim, Jin Soo; You, Choong Hyun

    2005-01-01

    To evaluate the stability of the segmental occlusal plane and anatomical line as the reference line for measuring the mesiodistal tooth angulation in panoramic radiography and to determine the mean angle and the range of the mesiodistal tooth angulation in Korean population with normal occlusions. Twenty nine subjects (15 men, 14 women) with normal occlusion were selected. A total of 29 panoramic radiograms were taken at normal head position and then 10 images of 5 subjects selected were repeatedly taken with repositioning 2 times at each of the head down (V-shaped occlusion) and up (horizontal occulsion) for evaluation of stability of adopted reference lines by using PM2002CC (Planmeca, Finland). The images were traced with adoption of two test reference lines and the long axes of the teeth. The mesial angles formed by each reference line and the long axes of the teeth were measured and analyzed. With anatomical reference line, the mesiodistal tooth angulations of the molars showed the significant difference by over 5 degree between the normal and each changed head position. With segmented occlusal reference line, deviations of mesiodistal tooth angulations by the two changed head positions were less than 1 degree. The means, standard deviations, and maximum and minimum values of mesiodistal tooth angulations to segmental occlusal reference line on panoramic radiography were determined. It would appear that mesiodistal tooth angulations to segmental occlusal plane as reference line in panograms are predictable as standards of normal occlusion and useful for evaluation of tooth arrangement between adjacent teeth.

  12. Mesiodistal tooth angulation to segmental occlusal plane in panoramic radiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Duk; Kim, Jin Soo; You, Choong Hyun [Chosun University College of Medicine, Kwangju (Korea, Republic of)

    2005-03-15

    To evaluate the stability of the segmental occlusal plane and anatomical line as the reference line for measuring the mesiodistal tooth angulation in panoramic radiography and to determine the mean angle and the range of the mesiodistal tooth angulation in Korean population with normal occlusions. Twenty nine subjects (15 men, 14 women) with normal occlusion were selected. A total of 29 panoramic radiograms were taken at normal head position and then 10 images of 5 subjects selected were repeatedly taken with repositioning 2 times at each of the head down (V-shaped occlusion) and up (horizontal occulsion) for evaluation of stability of adopted reference lines by using PM2002CC (Planmeca, Finland). The images were traced with adoption of two test reference lines and the long axes of the teeth. The mesial angles formed by each reference line and the long axes of the teeth were measured and analyzed. With anatomical reference line, the mesiodistal tooth angulations of the molars showed the significant difference by over 5 degree between the normal and each changed head position. With segmented occlusal reference line, deviations of mesiodistal tooth angulations by the two changed head positions were less than 1 degree. The means, standard deviations, and maximum and minimum values of mesiodistal tooth angulations to segmental occlusal reference line on panoramic radiography were determined. It would appear that mesiodistal tooth angulations to segmental occlusal plane as reference line in panograms are predictable as standards of normal occlusion and useful for evaluation of tooth arrangement between adjacent teeth.

  13. Graphene oxide and shape-controlled silver nanoparticle hybrids for ultrasensitive single-particle surface-enhanced Raman scattering (SERS) sensing.

    Science.gov (United States)

    Fan, Wei; Lee, Yih Hong; Pedireddy, Srikanth; Zhang, Qi; Liu, Tianxi; Ling, Xing Yi

    2014-05-07

    Graphene oxide (GO) is an emerging material for surface-enhanced Raman scattering (SERS) due to its strong chemical enhancement. Studying the SERS performance of plasmonic nanoparticle/GO hybrid materials at the single particle level is crucial for direct probing of the chemical effect of GO on plasmonic nanoparticles. In this work, we integrate GO and shape-controlled Ag nanoparticles to create hybrid nanomaterials, and the chemical enhancement arising from GO is investigated using single-particle SERS measurements. Ag nanoparticle@GO hybrid nanostructures are prepared by assembling Ag nanoparticles, including spheres, cubes and octahedra with GO sheets. The SERS behaviors of the hybrid nanostructures are characterized, and 2-3 times enhanced SERS intensities are detected from the Ag nanoparticle@GO hybrid nanostructures as compared to pure Ag nanoparticles. Furthermore, we probe the mechanism of SERS enhancement in the hybrid nanostructures by changing the surface coverage of GO on Ag octahedra, by using reduced GO in place of GO as well as by using probe molecules of different electronegativities. This hybrid system is an excellent candidate for single-particle SERS sensors. Sub-nanomolar levels of aromatic molecules are detected using a single Ag/GO hybrid nanomaterial. This as-prepared GO and shape-controlled Ag nanoparticle hybrid is capable of serving as a high performance SERS platform, providing new opportunities for efficient chemical and biological sensing applications.

  14. Miniscrew Supported Interim Tooth Replacement: A Temporary Alternative

    Directory of Open Access Journals (Sweden)

    Gurkeerat Singh

    2012-01-01

    Full Text Available Replacement of congenitally missing anterior tooth poses special problems in growing patients. Because an adolescent is typically self- conscious about removing an appliance and revealing a large edentulous space, a removable single tooth partial denture or retainer is an undesirable option. The temporary anchorage devices are invasive and the best recommended for malocclusion that cannot be effectively managed with conventional mechanics. The use of orthodontic miniscrews for interim restorations before the completion of skeletal growth has been used successfully unlike osseointegrated implants lacking the compensatory growth mechanisms of the natural dentition. The following case reports show an esthetic alternative to temporary tooth replacement using miniscrews.

  15. Influence of a Laser-Lok Surface on Immediate Functional Loading of Implants in Single-Tooth Replacement: Three-Year Results of a Prospective Randomized Clinical Study on Soft Tissue Response and Esthetics.

    Science.gov (United States)

    Guarnieri, Renzo; Grande, Maurizio; Ippoliti, Stefano; Iorio-Siciliano, Vincenzo; Riccitiello, Francesco; Farronato, Davide

    2015-01-01

    The purpose of the present prospective randomized study was to evaluate the influence of Laser-Lok microtextured surface on soft tissue peri-implant parameters and esthetics around immediate, functionally loaded implants for single-tooth replacement in the esthetic zone. This study included 77 patients divided into two groups based on different implants used: the control group had BioHorizons tapered internal non-Laser-Lok-type implants (NLL; n = 39) and the test group had BioHorizons tapered internal Laser-Lok-type implants (LL; n = 39). Outcome measures were survival, radiographic marginal bone-level changes, soft tissue parameters, and esthetics. One implant was lost in the test group and one in the control group, for a total survival rate of 96.1% after 3 years. Radiographically, mean crestal bone loss ± standard deviation was 0.59 ± 0.27 mm in the LL group compared with 1.17 ± 0.31 mm in the NLL group. A mean gain in papilla level of 0.41 ± 0.34 mm and 0.17 ± 0.36 mm was observed in the LL and the NLL groups, respectively, while the level of the midfacial peri-implant mucosa remained stable in both groups with no statistically significant differences (0.08 ± 0.42 mm for the LL group vs 0.06 ± 0.36 mm for the NLL group). The mean probing depth values in the LL and NLL groups were 0.58 ± 0.2 mm and 1.89 ± 0.3 mm, respectively. Within the limitations of this study, it was demonstrated that the clinical and esthetic outcome of immediate functional loading was more favorable for LL implants than for NLL implants.

  16. Magnetic domains and twin microstructure of single crystal Ni-Mn-Ga exhibiting magnetic shape memory effect

    Czech Academy of Sciences Publication Activity Database

    Heczko, Oleg; Kopecký, Vít; Fekete, Ladislav; Jurek, Karel; Kopeček, Jaromír; Straka, L.; Seiner, Hanuš

    2015-01-01

    Roč. 51, č. 11 (2015), s. 1-4, č. článku 2505304. ISSN 0018-9464 R&D Projects: GA ČR GB14-36566G Institutional support: RVO:68378271 ; RVO:61388998 Keywords : magnetic domain * magnetic shape memory * NiMnGa Subject RIV: BM - Solid Matter Physics ; Magnetism OBOR OECD: Condensed matter physics (including formerly solid state physics, supercond.) Impact factor: 1.277, year: 2015

  17. Magnetic domains and twin microstructure of single crystal Ni-Mn-Ga exhibiting magnetic shape memory effect

    Czech Academy of Sciences Publication Activity Database

    Heczko, Oleg; Kopecký, Vít; Fekete, Ladislav; Jurek, Karel; Kopeček, Jaromír; Straka, L.; Seiner, Hanuš

    2015-01-01

    Roč. 51, č. 11 (2015), s. 7150406 ISSN 0018-9464 R&D Projects: GA ČR GB14-36566G; GA MŠk LO1409 Grant - others:FUNBIO(XE) CZ.2.16/3.1.00/21568 Institutional support: RVO:68378271 ; RVO:61388998 Keywords : magnetic domain * magnetic shape memory * NiMnGa Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.277, year: 2015

  18. Cracked tooth syndrome

    OpenAIRE

    Maria Tanumihardja

    2009-01-01

    Cracked tooth syndrome is usually found in daily dental practice. The incidence of cracks teeth tends to increasing. People are living longer and keeping their teeth longer. As a consequence, people have more complex restoration and endodontic treatment, leaving teeth more prone to cracks. In addition, stressful lives may provoke unconscious habits such as clenching and bruxism which can induce cracks in teeth. However, many cracks teeth can be saved nowadays when the character...

  19. Effect of endodontic sealers on tooth color.

    Science.gov (United States)

    Meincke, Débora Könzgen; Prado, Maíra; Gomes, Brenda Paula Figueiredo; Bona, Alvaro Della; Sousa, Ezilmara Leonor Rolim

    2013-08-01

    One of the goals of endodontic treatment is the adequate filling of the root canal,which is often done using gutta-percha and sealer. It has been reported that sealer remnants in the coronary pulp chamber cause tooth color changes. Therefore, this study was designed to examine the effect of endodontic sealer remnants on tooth color, testing the hypothesis that sealers cause coronal color changes. Forty single-rooted human teeth were endodontically treated leaving excess sealer material in the coronary pulp chamber. The specimens were divided into four groups (n = 10) according to the endodontic sealer used (AH, AH Plus; EF, Endofill; EN,endome´ thasoneN; and S26, Sealer 26). Teeth were stored at 37 8C moist environment.Color coordinates (L*a*b*) were measured with a spectrophotometer before endodontic treatment(baseline-control), 24 h and 6 months after treatment. L*a*b* values were used to calculate color changes (DE). Data were statistically analyzed using Kruskal–Wallis and Mann–Whitney-U tests. Color changes were observed for all groups with S26 and EN producing the greatest mean DE values after 6 months. Endodontic sealer remnants affect tooth color confirming the experimental hypothesis. This study examined the effect of endodontic sealer remnants on tooth color, and observed that after 6 months, the sealers produced unacceptable color changes. 2012 Elsevier Ltd. All rights reserved.

  20. Mesh-shape-and-size controlled rapid-melting growth for the formation of single-crystalline (100), (110), and (111) Ge networks on insulators

    International Nuclear Information System (INIS)

    Mizushima, Ichiro; Toko, Kaoru; Ohta, Yasuharu; Sakane, Takashi; Sadoh, Taizoh; Miyao, Masanobu

    2011-01-01

    Single-crystalline-Ge (c-Ge) networks with various crystal orientations on insulators formed on Si substrates are essential for integrating high-speed and multifunctional devices onto the Si platform. c-Ge networks are realized by rapid-melting growth of mesh-patterned amorphous-Ge over large areas (500x250 μm 2 ) on (110) and (111) as well as (100) Si substrates by optimizing the shape and the size of the mesh. It is revealed that latent-heat generated at the growth front can be controlled by selecting mesh-shape-and-size, which suppresses the spontaneous nucleation. In addition, essential role of the growth-direction on preventing the rotational growth is clarified.

  1. Comparison of the root canal debridement ability of two single file systems with a conventional multiple rotary system in long oval-shaped root canals: In vitro study.

    Science.gov (United States)

    Khoshbin, Elham; Shokri, Abbas; Donyavi, Zakieh; Shahriari, Shahriar; Salehimehr, Golsa; Farhadian, Maryam; Kavandi, Zeinab

    2017-08-01

    This study sought to compare the root canal debridement ability of Neolix, Reciproc and ProTaper rotary systems in long oval-shaped root canals. Eighty five extracted single-rooted human teeth with long oval-shaped single root canals were selected and divided into three experimental groups(n=25) and one control group (n= 10). Root canals were filled with Vitapex radiopaque contrast medium and prepared with Neolix, Reciproc or ProTaper systems. The control group only received irrigation. Digital radiographs were obtained at baseline and postoperatively and subjected to digital subtraction. The percentage of reduction in contrast medium was quantified at 0-5 mm and 5-10 mm distances from the apex. The data were analyzed using one-way ANOVA and t-test. The mean percentage of the contrast medium removed was not significantly different in the 0-5mm segment among the three groups ( P =0.6). In the 5-10mm segment a significant difference was found in this regard among the ProTaper and Reciproc groups ( P =0.02) and the highest mean percentage of contrast medium was removed by ProTaper. But, difference between ProTaper and Neolix as well as Neolix and Reciproc was not significant. In Neolix ( P =0.024) and Reciproc ( P =0.002) systems, the mean percentage of the contrast medium removed from the 0-5mm segment was significantly greater than that in 5-10mm segment; however, this difference was not significant in ProTaper group ( P =0.069). Neolix single-file system may be a suitable alternative to ProTaper multiple-file system in debridement of long oval shaped canals. Key words: Root Canal Preparation, Debridement, Root Canal Therapy.

  2. Research on shape parameters of circular arc disc teeth for three-cone bit

    Directory of Open Access Journals (Sweden)

    Qin Hu

    2018-03-01

    Full Text Available Through the single row drilling experiment, this paper studied the regularity of the tooth shape parameter's influence to the disc teeth's rock-breaking effect, which provided some basis for the composite teeth type roller bit's combined experimental study and the structure design of the tooth type. This experimental research is only for the circular arc disc teeth which is arranged on the composite teeth type roller bit's main tooth. The experiments were designed using the method of orthogonal design and the results were analyzed by the fuzzy optimization method. The results show that the disc tooth's drilling effect is the best when the tip diameter is 2 mm, taper angle is 30° and the groove number is 8, and the disc tooth's drilling effect is the second best when the tip diameter is 3 mm, taper angle is 30° and the groove number is 7. The above two combined ways of drilling effect's difference is very small (the difference of the degree of the membership is 0.003.

  3. Stress-induced martensite variant reorientation in magnetic shape memory Ni–Mn–Ga single crystal studied by neutron diffraction

    Czech Academy of Sciences Publication Activity Database

    Molnár, Peter; Šittner, Petr; Lukáš, Petr; Hannula, S.-P.; Heczko, Oleg

    2008-01-01

    Roč. 17, č. 3 (2008), 035014/1-035014/4 ISSN 0964-1726 Institutional research plan: CEZ:AV0Z10100520; CEZ:AV0Z10480505 Keywords : NiMnGa single crystal * neutron diffraction * stress induced martensite reorientation Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.743, year: 2008

  4. Dental regenerative therapy: Stem cell transplantation and bioengineered tooth replacement

    Directory of Open Access Journals (Sweden)

    Kazuhisa Nakao

    2008-07-01

    Full Text Available For clinical treatment of tooth defects and tooth loss, nonbiotechnological approaches, such as the use of prostheses and implants, have generally been employed. Dental regenerative therapies which restore or replace defective teeth using autologous explants are being investigated using current understandings of developmental biology, stem cell biology, and regenerative medicine. Recently, dental tissue stem/progenitor cells, which can differentiate into dental cell lineages, have been identified in both impacted and erupted human teeth, and these cells can be used to regenerate some dental tissues. Tissue engineering using scaffold and cell aggregate methods may also be used to produce bioengineered teeth from dissociated cells for therapeutic applications of whole tooth replacement. Recent breakthroughs in single cell manipulation methods for the reconstitution of bioengineered tooth germ and the investigation of in vivo development of artificial tooth germ in the adult oral environment have been reported. These researches and developments will ultimately lead to the realization of dental regenerative therapies for partial repair by stem cell transplantation and for whole tooth replacement using bioengineered tooth germ.

  5. Impaired tooth eruption: a review.

    Science.gov (United States)

    Noffke, C E E; Chabikuli, N J; Nzima, N

    2005-11-01

    Eruption is the continuous process of movement of a tooth from its developmental location inside the jaw to its functional location in the mouth. Impaired tooth eruption, where this process is disturbed, is common in dental practice. It may manifest either as delayed or complete absence of eruption. Although unerupted teeth are usually asymptomatic, they may cause cosmetic and pathologic complications. The purpose of this article is to provide a review on the pathogenesis and differential radiographic interpretation of impaired tooth eruption.

  6. [Tooth eruption disturbances and syndromes].

    Science.gov (United States)

    Oosterkamp, B C M; Ockeloen, C W; Carels, C E L; Kuijpers-Jagtman, A M

    2014-04-01

    In the tooth eruption mechanism, various disturbances can appear as a result of gene mutations, a consequence of which can be that tooth eruption does not occur. There are 5 syndromes which involve the complete failure of several or even all teeth to erupt, specifically: cleidocranial dysplasia, Gardner's syndrome, osteopetrosis, mucopolysaccharidosis and GAPO syndrome. Some are very rare and will seldom be encountered in a dental practice, but they show how vulnerable the tooth eruption mechanism is. Dentists are generally the ones who identify a tooth eruption problem in a patient. Since syndromes can be associated with other disorders, additional investigation by a clinical geneticist is always important when a syndrome is suspected.

  7. Tooth Wear Inclination in Great Ape Molars.

    Science.gov (United States)

    Knight-Sadler, Jordan; Fiorenza, Luca

    2017-01-01

    Primate dietary diversity is reflected in their dental morphology, with differences in size and shape of teeth. In particular, the tooth wear angle can provide insight into a species' ability to break down certain foods. To examine dietary and masticatory information, digitized polygon models of dental casts provide a basis for quantitative analysis of wear associated with tooth attrition. In this study, we analyze and compare the wear patterns of Pongo pygmaeus, Gorilla gorillagorilla and Pan troglodytes schweinfurthii lower molars, focusing on the degree of inclination of specific wear facets. The variation in wear angles appears to be indicative of jaw movements and the specific stresses imposed on food during mastication, reflecting thus the ecology of these species. Orangutans exhibit flatter wear angles, more typical of a diet consisting of hard and brittle foods, while gorillas show a wear pattern with a high degree of inclination, reflecting thus their more leafy diet. Chimpanzees, on the other hand, show intermediate inclinations, a pattern that could be related to their highly variable diet. This method is demonstrated to be a powerful tool for better understanding the relationship between food, mastication and tooth wear processes in living primates, and can be potentially used to reconstruct the diet of fossil species. © 2017 S. Karger AG, Basel.

  8. [Comparison between the tooth length measured by cone-beam CT and the tooth length measured with vernier caliper].

    Science.gov (United States)

    Yang, Yi-qiang; Mi, Zhen-lin; Ge, Zhen-lin

    2013-11-01

    To evaluate the accuracy of cone-bean CT (CBCT) on the measurement of the tooth length. One hundred and sixty single root premolars extracted for orthodontic purposes were selected. The tooth length was measured with vernier caliper. The premolars were divided into 10 groups randomly, 16 premolars in each group.In each group, the teeth were lined in molar area, premolar area, canine area and anterior tooth area in maxilla and mandible. Then CBCT was taken, and the tooth length was measured using the software supplied by the manufacturer in coronal and sagittal plane. Accuracy was compared between vernier caliper measurement and CBCT measurement. The tooth length measured by CBCT was smaller than that measured with the vernier caliper. Significant differences were found in six areas, except the maxillary and mandibular premolar areas. With the increase of mesial-distal inclination or buccolingual torque angle, the difference between tooth length measured by CBCT and that measured with vernier caliper increased. The correlation between buccolingual torque angle (∠X1) and the coronal view of CBCT radiology tooth length (Spearmen index was 7.00, P caliper.

  9. Autogenous tooth transplantation: an alternative to replace extracted tooth

    Directory of Open Access Journals (Sweden)

    David B. Kamadjaja

    2015-09-01

    Full Text Available Background: The gold standard treatment to replace missing tooth is dental implants, however, in certain cases, such as in young patients its placement is contraindicated. Autogenous tooth transplantation, which has been widely done in Scandinavian countries for many years, may become a good alternative to overcome this problem. Purpose: This article attempted to provide information about the indication, treatment planning, surgical technique and the successful result of autogenous tooth transplantation. Case: A fifteen year old male patient presented with large caries and periapical disease of his lower left first molar, which was partially erupted and the roots was not fully formed in radiograph. Case management: Autogenous tooth transplantation procedure was performed consisting of extraction of #36, odontectomy of #38 followed by its implantation to socket #36 and fixation of the transplanted tooth to the adjacent teeth. Post operative evaluation was done on regular basis within 18 months period. There was no complaint, the tooth was clinically stable and no evidence of periodontal problem. Serial radiographs showed healing of alveolar bone and periodontal tissue, and the complete root formation was evident by 18 months post operatively. Conclusion: Autogenous tooth transplantation is a potential alternative to replace extracted tooth. Provided that the case be properly planned and operation carefully performed, successful result of this treatment can be achieved.

  10. A Systematic Study on Tooth Enamel Microstructures of Lambdopsalis bulla (Multituberculate, Mammalia)--Implications for Multituberculate Biology and Phylogeny.

    Science.gov (United States)

    Mao, Fangyuan; Wang, Yuanqing; Meng, Jin

    2015-01-01

    Tooth enamel microstructure is a reliable and widely used indicator of dietary interpretations and data for phylogenetic reconstruction, if all levels of variability are investigated. It is usually difficult to have a thorough examination at all levels of enamel structures for any mammals, especially for the early mammals, which are commonly represented by sparse specimens. Because of the random preservation of specimens, enamel microstructures from different teeth in various species are often compared. There are few examples that convincingly show intraspecific variation of tooth enamel microstructure in full dentition of a species, including multituberculates. Here we present a systematic survey of tooth enamel microstructures of Lambdopsalis bulla, a taeniolabidoid multituberculate from the Late Paleocene Nomogen Formation, Inner Mongolia. We examined enamel structures at all hierarchical levels. The samples are treated differently in section orientations and acid preparation and examined using different imaging methods. The results show that, except for preparation artifacts, the crystallites, enamel types, Schmelzmuster and dentition types of Lambdopsalis are relatively consistent in all permanent teeth, but the prism type, including the prism shape, size and density, may vary in different portions of a single tooth or among different teeth of an individual animal. The most common Schmelzmuster of the permanent teeth in Lambdopsalis is a combination of radial enamel in the inner and middle layers, aprismatic enamel in the outer layer, and irregular decussations in tooth crown area with great curvature. The prism seam is another comparably stable characteristic that may be a useful feature for multituberculate taxonomy. The systematic documentation of enamel structures in Lambdopsalis may be generalized for the enamel microstructure study, and thus for taxonomy and phylogenetic reconstruction, of multituberculates and even informative for the enamel study of

  11. The effect of the shape of single, sub-ms voltage pulses on the rates of surface immobilization and hybridization of DNA

    International Nuclear Information System (INIS)

    Cabeca, R; Rodrigues, M; Chu, V; Conde, J P; Prazeres, D M F

    2009-01-01

    Electric fields generated by single square and sinusoidal voltage pulses with amplitudes below 2 V were used to assist the covalent immobilization of single-stranded, thiolated DNA probes, onto a chemically functionalized SiO 2 surface and to assist the specific hybridization of single-stranded DNA targets with immobilized complementary probes. The single-stranded immobilized DNA probes were either covalently immobilized (chemisorption) or electrostatically adsorbed (physisorption) to a chemically functionalized surface. Comparing the speed of electric field assisted immobilization and hybridization with the corresponding control reactions (without electric field), an increase of several orders of magnitude is observed, with the reaction timescaled down from 1 to 2 h to a range between 100 ns and 1 ms. The influence of the shape of the voltage pulse (square versus sinusoidal) and its duration were studied for both immobilization and hybridization reactions. The results show that pulsed electric fields are a useful tool to achieve temporal and spatial control of surface immobilization and hybridization reactions of DNA.

  12. The shape and dynamics of the generation of the splash forms in single-phase systems after drop hitting

    Science.gov (United States)

    Sochan, Agata; Beczek, Michał; Mazur, Rafał; RyŻak, Magdalena; Bieganowski, Andrzej

    2018-02-01

    The splash phenomenon is being increasingly explored with the use of modern measurement tools, including the high-speed cameras. Recording images at a rate of several thousand frames per second facilitates parameterization and description of the dynamics of splash phases. This paper describes the impact of a single drop of a liquid falling on the surface of the same liquid. Three single-phase liquid systems, i.e., water, petrol, and diesel fuel, were examined. The falling drops were characterized by different kinetic energy values depending on the height of the fall, which ranged from 0.1 to 7.0 m. Four forms, i.e., waves, crowns, semi-closed domes, and domes, were distinguished depending on the drop energy. The analysis of the recorded images facilitated determination of the static and dynamic parameters of each form, e.g., the maximum height of each splash form, the width of the splash form at its maximum height, and the rate of growth of the splash form. We, Re, Fr, and K numbers were determined for all analyzed liquid systems. On the basis of the obtained values of dimensionless numbers, the areas of occurrence of characteristic splash forms were separated.

  13. Characteristic rotational behaviors of rod-shaped cargo revealed by automated five-dimensional single particle tracking.

    Science.gov (United States)

    Chen, Kuangcai; Gu, Yan; Sun, Wei; Bin Dong; Wang, Gufeng; Fan, Xinxin; Xia, Tian; Fang, Ning

    2017-10-12

    We report an automated single particle tracking technique for tracking the x, y, z coordinates, azimuthal and elevation angles of anisotropic plasmonic gold nanorod probes in live cells. These five spatial coordinates are collectively referred to as 5D. This method overcomes a long-standing challenge in distinguishing rotational motions from translational motions in the z-axis in differential interference contrast microscopy to result in full disclosure of nanoscale motions with high accuracy. Transferrin-coated endocytic gold nanorod cargoes initially undergo active rotational diffusion and display characteristic rotational motions on the membrane. Then as the cargoes being enclosed in clathrin-coated pits, they slow down the active rotation and experience a quiet period before they restore active rotational diffusion after fission and eventually being transported away from the original entry spots. Finally, the 3D trajectories and the accompanying rotational motions of the cargoes are resolved accurately to render the intracellular transport process in live cells.Distinguishing rotational motions from translational motions in the z-axis has been a long-standing challenge. Here the authors develop a five-dimensional single particle tracking method to detect rotational behaviors of nanocargos during clathrin-mediated endocytosis and intracellular transport.

  14. [Tooth eruption disturbances and syndromes

    NARCIS (Netherlands)

    Oosterkamp, B.A.M. van; Ockeloen, C.W.; Carels, C.E.L.; Kuijpers-Jagtman, A.M.

    2014-01-01

    In the tooth eruption mechanism, various disturbances can appear as a result of gene mutations, a consequence of which can be that tooth eruption does not occur. There are 5 syndromes which involve the complete failure of several or even all teeth to erupt, specifically: cleidocranial dysplasia,

  15. Broken or knocked out tooth

    Science.gov (United States)

    ... Drugs & Supplements Videos & Tools Español You Are Here: Home → Medical Encyclopedia → Broken or knocked out tooth URL of this page: // ... and fluid solution. Consider buying 1 for your home first aid kit . Also ... If your tooth is badly broken, your nerve endings may be exposed. You will ...

  16. Single pot synthesized gold nanoparticles using Hippophae rhamnoides leaf and berry extract showed shape-dependent differential nanobiotechnological applications.

    Science.gov (United States)

    Sharma, Bhavana; Deswal, Renu

    2018-04-04

    A facile one-pot green synthesis of gold nanoparticles (AuNPs) with different geometries was achieved using an underutilized Himalayan bioresource Hippophae rhamnoides. Aqueous leaf (LE) and berry extracts (BE) showed rapid synthesis of monodispersed spherical LEAuNPs (27 ± 3.2 nm) and anisotropic BEAuNPs (55 ± 4.5 nm) within 2 and 15 min, respectively. The Fourier-transform infrared (FTIR) spectroscopy showed involvement of polyphenolics/flavonoids in AuNPs reduction. LE AuNPs (IC 50 49 µg) exhibited higher antioxidant potential than BE AuNPs (IC 50 57 µg). Both BE nanotriangles and LE nanospheres exhibited cytotoxicity against Jurkat cell lines. These nanocatalysts also exhibited effective (80-99%) reductive degradation of structurally different carcinogenic azo dyes. Kinetic studies revealed that BE nanotriangles exhibited higher catalytic efficiency (14-67%) than LE nanospheres suggesting shape-dependent regulation of biological activities. The gas chromatography-mass spectrometry (GC-MS) analysis confirmed conversion of toxic methyl orange dye to non-toxic intermediates. Probable degradation mechanism involving adsorption and catalytic reduction of azo bonds was proposed. The present synthesis protocol provided a facile and energy saving procedure for rapid synthesis of highly stable nanoparticles with significant antioxidant and anticancer potential. This is the first report of H. rhamnoides-mediated green synthesis of multipurpose AuNPs as antioxidant, anticancer and nanocatalytic agents for treatment of dye contaminated waste water and future therapeutic applications.

  17. Tooth Fairy guilty of favouritism!

    Science.gov (United States)

    Patcas, Raphael; van Waes, Hubertus Jm; Daum, Moritz M; Landolt, Markus A

    2017-12-11

    To determine the proportion of children visited by the Tooth Fairy, the child-related factors that influence the likelihood of her visit, and the parent-related variables that affect the amount of money the Tooth Fairy leaves. Cross-sectional questionnaire study. Zürich, Switzerland. 3617 parents of children (mean age of children, 6.8 years; 51.9% girls) who had lost at least one deciduous tooth received a self-developed questionnaire; 1274 questionnaires were returned (35.2%). Primary outcome variables were the Tooth Fairy's visit after tooth loss and the amount of money given in case of a visit. Child- and parent-related variables were assessed as predictors of the main outcomes. Most parents (71.0%) reported that the Tooth Fairy visited their child. She usually exchanged the lost tooth for money (55.8% of visits) or placed money next to the tooth (40.7%); rarely did she take the tooth without pecuniary substitution. The Tooth Fairy left an average of 7.20 Swiss francs (approximately AU$9.45). The Tooth Fairy favoured visiting for the teeth of older children (odds ratio [OR], per year, 1.87; 95% CI, 1.09-3.21), of boys (OR, 2.65; 95% CI, 1.09-6.42), and of children who believed in her (OR, 4.12; 95% CI, 1.77-9.64). The amount of money was influenced by maternal, but not paternal socio-demographic factors, including level of education (OR, per level, 0.78; 95% CI, 0.66-0.92) and country of origin (OR, Western countries v non-Western countries, 2.35; 95% CI, 1.20-4.62). The Tooth Fairy does not visit all children after tooth loss, displaying clear preferences in her choice of business partners. The odds of a visit are dramatically increased if she is believed in, and the value of a deciduous tooth is influenced by socio-demographic factors.

  18. A horn shaped air-cooled 300 MHz applicator for use in single field or parallel opposed phased system (POPAS)

    International Nuclear Information System (INIS)

    Bicher, H.I.; Moore, D.W.

    1985-01-01

    A 20cm x 23cm standard design 300 MHz horn waveguide may be used to heat tumors at moderate depth. The heating patterns have been observed using two such applicators excited in phase in parallel opposition about phantoms and living subjects. Both depth and homogeneity of heating profiles were greatly enhanced using the parallel opposed system by the convergence of the waveforms. Experiments performed in pigs and human volunteers show the feasibility of heating several anatomical regions. The pelvis, neck, axilla, limbs and single lung regions provide good candidates for this treatment method. The homogeneity of and treatment accessibility of in vivo fields and counterplay of high and low blood flow regions in normal and tumorous tissue are currently under study

  19. Detection of Single Tree Stems in Forested Areas from High Density ALS Point Clouds Using 3d Shape Descriptors

    Science.gov (United States)

    Amiri, N.; Polewski, P.; Yao, W.; Krzystek, P.; Skidmore, A. K.

    2017-09-01

    Airborne Laser Scanning (ALS) is a widespread method for forest mapping and management purposes. While common ALS techniques provide valuable information about the forest canopy and intermediate layers, the point density near the ground may be poor due to dense overstory conditions. The current study highlights a new method for detecting stems of single trees in 3D point clouds obtained from high density ALS with a density of 300 points/m2. Compared to standard ALS data, due to lower flight height (150-200 m) this elevated point density leads to more laser reflections from tree stems. In this work, we propose a three-tiered method which works on the point, segment and object levels. First, for each point we calculate the likelihood that it belongs to a tree stem, derived from the radiometric and geometric features of its neighboring points. In the next step, we construct short stem segments based on high-probability stem points, and classify the segments by considering the distribution of points around them as well as their spatial orientation, which encodes the prior knowledge that trees are mainly vertically aligned due to gravity. Finally, we apply hierarchical clustering on the positively classified segments to obtain point sets corresponding to single stems, and perform ℓ1-based orthogonal distance regression to robustly fit lines through each stem point set. The ℓ1-based method is less sensitive to outliers compared to the least square approaches. From the fitted lines, the planimetric tree positions can then be derived. Experiments were performed on two plots from the Hochficht forest in Oberösterreich region located in Austria.We marked a total of 196 reference stems in the point clouds of both plots by visual interpretation. The evaluation of the automatically detected stems showed a classification precision of 0.86 and 0.85, respectively for Plot 1 and 2, with recall values of 0.7 and 0.67.

  20. Shape memory polymers

    Science.gov (United States)

    Wilson, Thomas S.; Bearinger, Jane P.

    2015-06-09

    New shape memory polymer compositions, methods for synthesizing new shape memory polymers, and apparatus comprising an actuator and a shape memory polymer wherein the shape memory polymer comprises at least a portion of the actuator. A shape memory polymer comprising a polymer composition which physically forms a network structure wherein the polymer composition has shape-memory behavior and can be formed into a permanent primary shape, re-formed into a stable secondary shape, and controllably actuated to recover the permanent primary shape. Polymers have optimal aliphatic network structures due to minimization of dangling chains by using monomers that are symmetrical and that have matching amine and hydroxyl groups providing polymers and polymer foams with clarity, tight (narrow temperature range) single transitions, and high shape recovery and recovery force that are especially useful for implanting in the human body.

  1. Microfilament-coordinated adhesion dynamics drives single cell migration and shapes whole tissues [version 1; referees: 4 approved

    Directory of Open Access Journals (Sweden)

    Rocio Aguilar-Cuenca

    2017-02-01

    Full Text Available Cell adhesion to the substratum and/or other cells is a crucial step of cell migration. While essential in the case of solitary migrating cells (for example, immune cells, it becomes particularly important in collective cell migration, in which cells maintain contact with their neighbors while moving directionally. Adhesive coordination is paramount in physiological contexts (for example, during organogenesis but also in pathology (for example, tumor metastasis. In this review, we address the need for a coordinated regulation of cell-cell and cell-matrix adhesions during collective cell migration. We emphasize the role of the actin cytoskeleton as an intracellular integrator of cadherin- and integrin-based adhesions and the emerging role of mechanics in the maintenance, reinforcement, and turnover of adhesive contacts. Recent advances in understanding the mechanical regulation of several components of cadherin and integrin adhesions allow us to revisit the adhesive clutch hypothesis that controls the degree of adhesive engagement during protrusion. Finally, we provide a brief overview of the major impact of these discoveries when using more physiological three-dimensional models of single and collective cell migration.

  2. Effect of crystal shape on neutron rocking curves of perfect single crystals designed for ultra-small-angle scattering experiments

    International Nuclear Information System (INIS)

    Freund, A K; Rehm, C

    2014-01-01

    The present study has been conducted in the framework of the channel-cut crystal design for the Kookaburra ultra-small-angle neutron scattering (USANS) instrument to be installed at the OPAL reactor of ANSTO. This facility is based on the classical Bonse-Hart method that uses two multiple-reflection crystal systems. The dynamical theory of diffraction by perfect crystals distinguishes two cases: the Darwin case applying to infinitely thick crystals and the Ewald solution for very small absorption taking into account the reflection from the rear face of a plane-parallel crystal reflecting in Bragg geometry. The former is preferable because it yields narrower rocking curves. To prevent the neutrons to 'see' the rear face, grooves were machined into the backside of perfect Si test crystals for single reflection and filled with neutron absorbing material. These samples were examined at the S18 instrument of the Institut Laue-Langevin. Unexpectedly the crystals with empty slots showed an increase of the rocking curve width. When filling the slots with an absorber the widths decreased, but without reaching that of the Darwin curve. Understanding the results and achieving a successful crystal design call for the development of a theory that permits to describe neutron diffraction from crystals with a structured back face.

  3. Effect of crystal shape on neutron rocking curves of perfect single crystals designed for ultra-small-angle scattering experiments

    Science.gov (United States)

    Freund, A. K.; Rehm, C.

    2014-07-01

    The present study has been conducted in the framework of the channel-cut crystal design for the Kookaburra ultra-small-angle neutron scattering (USANS) instrument to be installed at the OPAL reactor of ANSTO. This facility is based on the classical Bonse-Hart method that uses two multiple-reflection crystal systems. The dynamical theory of diffraction by perfect crystals distinguishes two cases: the Darwin case applying to infinitely thick crystals and the Ewald solution for very small absorption taking into account the reflection from the rear face of a plane-parallel crystal reflecting in Bragg geometry. The former is preferable because it yields narrower rocking curves. To prevent the neutrons to "see" the rear face, grooves were machined into the backside of perfect Si test crystals for single reflection and filled with neutron absorbing material. These samples were examined at the S18 instrument of the Institut Laue-Langevin. Unexpectedly the crystals with empty slots showed an increase of the rocking curve width. When filling the slots with an absorber the widths decreased, but without reaching that of the Darwin curve. Understanding the results and achieving a successful crystal design call for the development of a theory that permits to describe neutron diffraction from crystals with a structured back face.

  4. Abiotic tooth enamel

    Science.gov (United States)

    Yeom, Bongjun; Sain, Trisha; Lacevic, Naida; Bukharina, Daria; Cha, Sang-Ho; Waas, Anthony M.; Arruda, Ellen M.; Kotov, Nicholas A.

    2017-03-01

    Tooth enamel comprises parallel microscale and nanoscale ceramic columns or prisms interlaced with a soft protein matrix. This structural motif is unusually consistent across all species from all geological eras. Such invariability—especially when juxtaposed with the diversity of other tissues—suggests the existence of a functional basis. Here we performed ex vivo replication of enamel-inspired columnar nanocomposites by sequential growth of zinc oxide nanowire carpets followed by layer-by-layer deposition of a polymeric matrix around these. We show that the mechanical properties of these nanocomposites, including hardness, are comparable to those of enamel despite the nanocomposites having a smaller hard-phase content. Our abiotic enamels have viscoelastic figures of merit (VFOM) and weight-adjusted VFOM that are similar to, or higher than, those of natural tooth enamels—we achieve values that exceed the traditional materials limits of 0.6 and 0.8, respectively. VFOM values describe resistance to vibrational damage, and our columnar composites demonstrate that light-weight materials of unusually high resistance to structural damage from shocks, environmental vibrations and oscillatory stress can be made using biomimetic design. The previously inaccessible combinations of high stiffness, damping and light weight that we achieve in these layer-by-layer composites are attributed to efficient energy dissipation in the interfacial portion of the organic phase. The in vivo contribution of this interfacial portion to macroscale deformations along the tooth’s normal is maximized when the architecture is columnar, suggesting an evolutionary advantage of the columnar motif in the enamel of living species. We expect our findings to apply to all columnar composites and to lead to the development of high-performance load-bearing materials.

  5. Feasibility study of a single-shot 3D electron bunch shape monitor with an electro-optic sampling technique

    Directory of Open Access Journals (Sweden)

    Yuichi Okayasu

    2013-05-01

    Full Text Available We developed a three-dimensional electron bunch charge distribution (3D-BCD monitor with single-shot detection, and a spectral decoding based electro-optic (EO sampling technique for a nondestructive monitor enables real-time reconstruction of the three-dimensional distribution of a bunch charge. We realized three goals by simultaneously probing a number of Pockels EO crystals that surround the electron beam axis with hollow and radial polarized laser pulses. First, we performed a feasibility test as a simple case of a 3D-BCD monitor probing two ZnTe crystals as EO detectors installed on the opposite angle to the electron beam axis and confirmed that we simultaneously obtained both EO signals. Since the adopted hollow probe laser pulse is not only radially polarized but also temporally shifted azimuthally, some disorders in the radial polarization distribution of such a laser pulse were numerically analyzed with a plane-wave expansion method. Based on the above investigations, the 3D-BCD monitor is feasible both in experimental and numerical estimations. Furthermore, we previously developed a femtosecond response organic crystal as a Pockels EO detector and a broadband probe laser (≥350  nm in FWHM; the 3D-BCD monitor realizes 30- to 40-fs (FWHM temporal resolution. Eventually, the monitor is expected to be equipped in such advanced accelerators as XFEL to measure and adjust the electron bunch charge distribution in real time. The 3D-BCD measurement works as a critical tool to provide feedback to seeded FELs.

  6. Decoronation for the management of an ankylosed young permanent tooth.

    Science.gov (United States)

    Sapir, Shabtai; Shapira, Joseph

    2008-02-01

    Replacement resorption rate is a variable process, and is dependent on age, basal metabolic rate, extra-alveolar time, treatment prior to replantation, amount of root dentin, severity of trauma, and extent of periodontal ligament necrosis. In patients 7-16 years old a tooth is lost 3-7 years after the onset of root resorption. The complications that may develop as a consequence of ankylosis of a permanent incisor in children are due to the inevitable early loss of the traumatized tooth and local arrest of alveolar bone development. An ankylosed tooth should be removed before the changes become so pronounced that they compromise future prosthetic treatment. The treatment options may involve: interceptive regenerative treatment, early extraction of the ankylosed tooth, orthodontic space closure, intentional replantation, extraction of the ankylosed tooth followed with immediate ridge augmentation/preservation, auto-transplantation, single tooth dento-osseous osteotomy, and decoronation. The purpose of this article was to review the considerations involved in the decision-making concerning the use of the decoronation technique for the treatment of a permanent incisor diagnosed as ankylosed.

  7. Tooth wear and associated risk factors in a sample of Australian primary school children.

    Science.gov (United States)

    Fung, A; Brearley Messer, L

    2013-06-01

    Anecdotally, tooth wear is increasing, perhaps attributable to diet. The irreversible surface loss may result in sensitivity and loss of form and function. Little data exist on the prevalence of tooth wear in Australian children. This study investigated consumption of potentially erosive foods and drinks, examining the prevalence, distribution of tooth wear and associations in a sample of children. Parents of 350, 6-12-year-olds reported their child's oral hygiene, dietary intake, medical and dental histories; 154 children (subsample) were examined. Associations were studied with single and multivariable analyses. Tooth wear was parentally reported for 17% (59 children of the study population) and observed in 66% (102 of the subsample), particularly affecting primary teeth. Significant risk factors for parentally reported tooth wear were: consuming 2-4 cups soft drink/day (OR = 9.52), citrus flavoured sweets/gums ≥1/day (5.10), citrus fruits 1-2/wk (4.28); tooth grinding (5.32); medical condition present (2.48); male gender (2.80). Drinking 2-4 cups fruit juice/day was a significant risk factor for both parentally reported (3.23) and observed tooth wear (3.97). Tooth wear appeared under-reported as some parents were unaware their child's teeth were affected. Significant risk factors for tooth wear were identifiable from children's histories. Risk factors should be addressed early so that tooth wear in the primary dentition does not affect permanent teeth. © 2013 Australian Dental Association.

  8. Three-dimensional analysis of tooth dimensions in the MSX1-missense mutation

    NARCIS (Netherlands)

    Creton, Marijn; van den Boogaard, Marie-Jose; Maal, Thomas; Verhamme, Luc; Fennis, Willem; Carels, Carine; Kuijpers-Jagtman, Anne Marie; Cune, Marco

    A novel, 3D technique to measure the differences in tooth crown morphology between the MSX1 cases and non-affected controls was designed to get a better understanding of dental phenotype-genotype associations. Eight Dutch subjects from a single family with tooth agenesis, all with an established

  9. Three-dimensional analysis of tooth dimensions in the MSX1-missense mutation

    NARCIS (Netherlands)

    Creton, M.; Boogaard, M.J. van den; Maal, T.J.; Verhamme, L.M.; Fennis, W.M.M.; Carels, C.E.L.; Kuijpers-Jagtman, A.M.; Cune, M.

    2013-01-01

    OBJECTIVES: A novel, 3D technique to measure the differences in tooth crown morphology between the MSX1 cases and non-affected controls was designed to get a better understanding of dental phenotype-genotype associations. MATERIALS AND METHODS: Eight Dutch subjects from a single family with tooth

  10. Hypercementosis and odontogenic epithelial hyperplasia associated with a tooth root remnant mimicking a neoplasm. A case report.

    Science.gov (United States)

    Zustin, J; Friedrich, R E

    2010-01-01

    Hypercementosis presents as painless, single or multiple non-neoplastic cementum formation beyond the physiological limits of the tooth. It often occurs in the apical area of the involved tooth following infection, chemical or mechanical trauma. We report on radiographic and histopathological findings in a single case of late intraosseous hypercementosis and odontogenic epithelial hyperplasia associated with a minute apical tooth root remnant years after its extraction, mimicking a tumour.

  11. Root canal treatment of mandibular second premolar tooth with taurodontism

    Directory of Open Access Journals (Sweden)

    Vujašković Mirjana

    2008-01-01

    Full Text Available INTRODUCTION Taurodontism is a morphoanatomical change in the shape of a tooth. An enlarged body of a tooth with smaller than usual roots is a characteristic feature. Internal tooth anatomy correlates with this appearance, which means that a taurodontal tooth has a large pulp chamber and apically positioned furcations. This dental anomaly may be associated with different syndromes and congenital discoders. CASE OUTLINE The case report presents the patient of a rare case of taurodontism in the mandibular second premolar with chronic periodontitis. Endodontic treatment was performed after dental history and clinical examination. Special care is required in all segments of endodontic treatment of a taurodontal tooth from the identification orifice, canal exploration, determining working length, cleaning and shaping and obturation of the root canal. Precurved K-file was used for canal exploration and location of the furcation. One mesial and one distal canal with the buccal position were identified in the apical third of the root canal. The working lengths of two canals were determined by radiographic interpretation with two K-files in each canal and verified with the apex locator. During canal instrumentation, the third canal was located in the disto-lingual position. The working length of the third canal was established using the apex locator. CONCLUSION Thorough knowledge of tooth anatomy and its variations can lead to lower percentage of endodontic failure. Each clinical case involving these teeth should be investigated carefully, clinically and radiographically to detect additional root canals. High quality radiographs from different angles and proper instrumentarium improve the quality of endodontic procedure.

  12. Tooth fragment reattachment technique on a pluri traumatized tooth

    OpenAIRE

    Giuseppe Lo Giudice; Frank Lipari; Angelo Lizio; Gabriel Cervino; Marco Cicciù

    2012-01-01

    This case report describes and analyses a tooth fragment reattachment technique used to resolve crown fractures of the anterior teeth. This treatment allows a conservative approach to traumatic coronal lesions offering a better possibility of maintaining aesthetics and function. The authors have illustrated here a clinical case of a fractured incisor. This case is characterized by several traumas on the same tooth that required different therapeutic solutions. We used an easy and ultra-conser...

  13. Detecting gear tooth fracture in a high contact ratio face gear mesh

    Science.gov (United States)

    Zakrajsek, James J.; Handschuh, Robert F.; Lewicki, David G.; Decker, Harry J.

    1995-01-01

    This paper summarized the results of a study in which three different vibration diagnostic methods were used to detect gear tooth fracture in a high contact ratio face gear mesh. The NASA spiral bevel gear fatigue test rig was used to produce unseeded fault, natural failures of four face gear specimens. During the fatigue tests, which were run to determine load capacity and primary failure mechanisms for face gears, vibration signals were monitored and recorded for gear diagnostic purposes. Gear tooth bending fatigue and surface pitting were the primary failure modes found in the tests. The damage ranged from partial tooth fracture on a single tooth in one test to heavy wear, severe pitting, and complete tooth fracture of several teeth on another test. Three gear fault detection techniques, FM4, NA4*, and NB4, were applied to the experimental data. These methods use the signal average in both the time and frequency domain. Method NA4* was able to conclusively detect the gear tooth fractures in three out of the four fatigue tests, along with gear tooth surface pitting and heavy wear. For multiple tooth fractures, all of the methods gave a clear indication of the damage. It was also found that due to the high contact ratio of the face gear mesh, single tooth fractures did not significantly affect the vibration signal, making this type of failure difficult to detect.

  14. In-vitro Assessing the Shaping Ability of Three Nickel-Titanium Rotary Single File Systems by Cone Beam Computed Tomography

    Directory of Open Access Journals (Sweden)

    Ali Imad Al-Asadi

    2018-02-01

    Full Text Available Aim of the study was to evaluate the canal transportation and centering ability of three nickel-titanium single file rotary systems by cone beam computed tomography (CBCT. Materials and methods: Thirty permanent maxillary first molar with a range of mesiobuccal canals curvature from 20-30 degree were selected and assigned into three groups (n=10, according to the biomechanical preparation system used: Hyflex EDM (HF, Reciproc blue (RB and OneShape (OS. The sampled were scanned by CBCT after being mounted on customized acrylic base and then rescanned after the instrumentation. Slices from the axial section were taken from both exposures at 3 mm, 6 mm and 9 mm from the root apex corresponding to the apical, middle, and coronal third respectively. Data were statistically analyzed using Kurskal-Wallis and Mann-Whitney U tests at the 5% confidence level. Results: The results showed that there were no significant differences at the apical and coronal third and a significant difference at the middle third regarding canal transportation. However, there was a significant difference at the apical third and no significant difference at the middle and coronal third regarding centering ratio. Conclusion: It was concluded that the three single rotary systems reported a degree in canal transportation and centric ratio but the Hyflex EDM reported the least one.

  15. A Rare Bilateral Presentation of Multiple Dens Invaginatus, Shovel-Shaped Incisor and Talon Cusp With Mesiodens.

    Science.gov (United States)

    Hegde, S; Jain, M; Shubha, A B

    2014-01-01

    The aim of this paper is to describe a unique and unusual case of concomitant appearance of morphological dental anomalies in the maxillary anterior region, along with its management in a patient with no systemic abnormality. This case report describes the clinical and radiographic features of talon cusp, dens invaginatus, shovel-shaped incisors and a supernumerary tooth occurring in a single patient, which is a rare presentation. All 4 permanent maxillary incisors had dens invaginatus, the permanent maxillary canines showed the presence of talon cusps, the permanent maxillary central incisors were shovel-shaped and an erupted mesiodens was also observed. Treatment included restorative, surgical and orthodontic approaches.

  16. NSAIDs in orthodontic tooth movement

    Directory of Open Access Journals (Sweden)

    Muthukumar Karthi

    2012-01-01

    Full Text Available Orthodontic tooth movement is basically a biological response toward a mechanical force. The movement is induced by prolonged application of controlled mechanical forces, which create pressure and tension zones in the periodontal ligament and alveolar bone, causing remodeling of tooth sockets. Orthodontists often prescribe drugs to manage pain from force application to biologic tissues. Nonsteroidal anti-inflammatory drugs (NSAIDs are the drugs usually prescribed. NSAIDs block prostaglandin synthesis and result in slower tooth movement. Prostaglandins have been found to play a direct role in bone resorption. Aspirin, acetaminophen, ibuprofen, diclofenac, vadecoxib, and celecoxib are the commonly prescribed drugs. Acetaminophen is the drug of choice for orthodontic pain without affecting orthodontic tooth movement.

  17. Erosive tooth wear in children

    NARCIS (Netherlands)

    Carvalho, T.S.; Lussi, A.; Jaeggi, T.; Gambon, D.L.; Lussi, A.; Ganss, C.

    2014-01-01

    Erosive tooth wear in children is a common condition. Besides the anatomical differences between deciduous and permanent teeth, additional histological differences may influence their susceptibility to dissolution. Considering laboratory studies alone, it is not clear whether deciduous teeth are

  18. Staircase and saw-tooth field emission steps from nanopatterned n-type GaSb surfaces

    CERN Document Server

    Kildemo, M.; Le Roy, S.; Søndergård, E.

    2009-01-01

    High resolution field emission experiments from nanopatterned GaSb surfaces consisting of densely packed nanocones prepared by low ion-beam-energy sputtering are presented. Both uncovered and metal-covered nanopatterned surfaces were studied. Surprisingly, the field emission takes place by regular steps in the field emitted current. Depending on the field, the steps are either regular, flat, plateaus, or saw-tooth shaped. To the author’s knowledge, this is the first time that such results have been reported. Each discrete jump in the field emission may be understood in terms of resonant tunneling through an extended surface space charge region in an n-type, high aspect ratio, single GaSb nanocone. The staircase shape may be understood from the spatial distribution of the aspect ratio of the cones.

  19. Biogeneric tooth: a new mathematical representation for tooth morphology in lower first molars.

    Science.gov (United States)

    Mehl, Albert; Blanz, Volker; Hickel, Reinhard

    2005-08-01

    A mathematical representation of tooth morphology may help to improve and automate restorative computer-aided design processes, virtual dental education, and parametric morphology. However, to date, no quantitative formulation has been identified for the description of dental features. The aim of this study was to establish and to validate a mathematical process for describing the morphology of first lower molars. Stone replicas of 170 caries-free first lower molars from young patients were measured three-dimensionally with a resolution of about 100,000 points. First, the average tooth was computed, which captures the common features of the molar's surface quantitatively. For this, the crucial step was to establish a dense point-to-point correspondence between all teeth. The algorithm did not involve any prior knowledge about teeth. In a second step, principal component analysis was carried out. Repeated for 3 different reference teeth, the procedure yielded average teeth that were nearly independent of the reference (less than +/- 40 microm). Additionally, the results indicate that only a few principal components determine a high percentage of the three-dimensional shape variability of first lower molars (e.g. the first five principal components describe 52% of the total variance, the first 10 principal components 72% and the first 20 principal components 83%). With the novel approach presented in this paper, surfaces of teeth can be described efficiently in terms of only a few parameters. This mathematical representation is called the 'biogeneric tooth'.

  20. SEM Analysis of Tooth Enamel

    OpenAIRE

    Azinović, Zoran; Keros, Jadranka; Buković, Dino; Azinović, Ana

    2003-01-01

    SEM analysis contains researches of tooth enamel surfaces of two populations. First group of samples is tooth enamel of prehistorically ancestor from Vu~edol and the second group of samples is enamel of modern Croatian citizen. Even on small number of human teeth samples from cooperage site of Vu~edol (3,000 BC) and today’s Croatian people, we can conclude about chewing biometry of prehistorically ancestors and today’s modern Croatian people, comparing interspecifically the mor...

  1. Orthodontic tooth movement and bioelectricity.

    OpenAIRE

    Karanth H; Shetty K

    2001-01-01

    Research in the field of orthodontics is now focused on the biology of tooth movement. Advanced molecular biology techniques has showed the researchers new avenue towards finding answers to the questions asked for the last few decades. Now it is possible for the researches to explore the lacunae in the field. One such field is, pharmaco-therapeutically or electrophysiologically enhancing the rate of tooth movement, improving the stability of the results, augmenting the anchorage. The voltage ...

  2. Visualization of Tooth for Non-Destructive Evaluation from CT Images

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Hui; Chae, Ok Sam [Kyung Hee University, Seoul (Korea, Republic of)

    2009-06-15

    This paper reports an effort to develop 3D tooth visualization system from CT sequence images as a part of the non-destructive evaluation suitable for the simulation of endodontics, orthodontics and other dental treatments. We focus on the segmentation and visualization for the individual tooth. In dental CT images teeth are touching the adjacent teeth or surrounded by the alveolar bones with similar intensity. We propose an improved level set method with shape prior to separate a tooth from other teeth as well as the alveolar bones. Reconstructed 3D model of individual tooth based on the segmentation results indicates that our technique is a very conducive tool for tooth visualization, evaluation and diagnosis. Some comparative visualization results validate the non-destructive function of our method.

  3. When is an implant ready for a tooth?

    Science.gov (United States)

    Tupac, Robert G

    2003-12-01

    The capability of placing an osseointegrated implant at the time of tooth extraction and immediately placing a restoration on the implant depends upon a number of factors. This paper describes the traditional Brånemark protocol, the evolution of single-stage surgery, the guidelines for immediate placement, the measurement of implant stability, and the considerations critical to immediately loading.

  4. Analysis of split tooth as an unstudied reason for tooth extraction

    OpenAIRE

    Osaghae, Ifueko Patience; Azodo, Clement Chinedu

    2014-01-01

    Background Split tooth is an unstudied reason for tooth extraction. The purpose of this study was to determine and analyze split tooth as a reason for extraction in a dental clinic in Benin City. Methods The prospective study was carried out on 669 patients having tooth extraction between May, 2005 and December, 2012. Over the period of the study, diagnosis and tooth extraction were done by three dentists of more five years practice experience. The indications for tooth extraction were noted ...

  5. In vitro tooth cleaning efficacy of manual toothbrushes around brackets.

    Science.gov (United States)

    Schätzle, Marc; Imfeld, Thomas; Sener, Beatrice; Schmidlin, Patrick R

    2009-02-01

    The purpose of this laboratory study was to assess the potential cleaning efficacy of nine different toothbrushes around brackets in vitro. Standard and Mini Diamond brackets were fixed on coloured teeth in a special model, coated with white titanium oxide, brushed in a machine with different manual toothbrushes (three different types: planar, staged, and v-shaped bristle field), and tested with a horizontal motion for 1 minute. After brushing, the teeth were scanned and the black surfaces were planimetrically assessed using a grey scale. Tooth areas which were black again after brushing indicated tooth surface contact of the filaments. The remaining white tooth areas around the brackets indicated 'plaque-retentive' niches. Statistical analysis was carried out using the Kruskal-Wallis one-way test of variance for individual comparison. Bonferroni adjustment was used for multiple testing, and comparison of bracket size with Wilcoxon signed rank test. In the most critical area of 2 mm around the brackets, there was no statistically significant difference between the different toothbrushes evaluated. The untouched area ranged from 11 to 26 per cent of the initially whitened tooth surface. By pooling the toothbrushes according to their design, the median cleaning efficacy of the v-shaped (73.1 per cent) and staged (75.6 per cent) toothbrushes resulted in significantly superior cleaning efficacy than planar toothbrushes (60.7 per cent) for standard brackets. For mini bracket type, staged toothbrushes showed a significantly better mean cleaning efficacy (77.8 per cent) than planar (65 per cent) and v-shaped (72.4 per cent) toothbrushes. Staged and v-shaped brush designs resulted in superior cleaning efficacy of teeth with fixed orthodontic attachments than toothbrushes with a planar bristle field. None of the tested toothbrushes showed a consistent, significantly higher cleaning efficacy than the others in this in vitro experiment.

  6. Effect of repeated immersion solution cycles on the color stability of denture tooth acrylic resins

    OpenAIRE

    Paulo Maurício Batista da Silva; Emílio José Tabaré Rodríguez Acosta; Matheus Jacobina; Luciana de Rezende Pinto; Vinícius Carvalho Porto

    2011-01-01

    OBJECTIVE: Chemical solutions have been widely used for disinfection of dentures, but their effect on color stability of denture tooth acrylic resins after repeated procedures is still unclear. The aim of this in vitro study was to evaluate whether repeated cycles of chemical disinfectants affected the color stability of two denture tooth acrylic resins. MATERIAL AND METHODS: Sixty disc-shaped specimens (40 mm x 3 mm) were fabricated from two different brands (Artiplus and Trilux) of denture ...

  7. Hippo pathway/Yap regulates primary enamel knot and dental cusp patterning in tooth morphogenesis.

    Science.gov (United States)

    Kwon, Hyuk-Jae Edward; Li, Liwen; Jung, Han-Sung

    2015-11-01

    The shape of an individual tooth crown is primarily determined by the number and arrangement of its cusps, i.e., cusp patterning. Enamel knots that appear in the enamel organ during tooth morphogenesis have been suggested to play important roles in cusp patterning. Animal model studies have shown that the Hippo pathway effector Yap has a critical function in tooth morphogenesis. However, the role of the Hippo pathway/Yap in cusp patterning has not been well documented and its specific roles in tooth morphogenesis remain unclear. Here, we provide evidence that Yap is a key mediator in tooth cusp patterning. We demonstrate a correlation between Yap localization and cell proliferation in developing tooth germs. We also show that, between the cap stage and bell stage, Yap is crucial for the suppression of the primary enamel knot and for the patterning of secondary enamel knots, which are the future cusp regions. When Yap expression is stage-specifically knocked down during the cap stage, the activity of the primary enamel knot persists into the bell-stage tooth germ, leading to ectopic cusp formation. Our data reveal the importance of the Hippo pathway/Yap in enamel knots and in the proper patterning of tooth cusps.

  8. A Conservative Treatment Approach to Replacing a Missing Anterior Tooth

    Directory of Open Access Journals (Sweden)

    Kunwarjeet Singh

    2014-01-01

    Full Text Available An implant-supported crown or conventionally fixed partial denture is the most common treatment modality to replace a missing anterior tooth but a more conservative approach, with a fiber reinforced composite resin FPD, can be used to replace a missing anterior tooth in young patients or when the patient does not agree for an implant, or conventional FPD or RPD therapy. It is an esthetic, conservative single sitting chairside procedure which can be used as a definitive treatment alternative in certain clinical situations for esthetic and functional replacement of a missing anterior tooth. To achieve desirable results, putty matrix was used for proper positioning of the pontic during direct fabrication of FRCFPD.

  9. "Depth-profiling" and quantitative characterization of the size, composition, shape, density, and morphology of fine particles with SPLAT, a single-particle mass spectrometer.

    Science.gov (United States)

    Zelenyuk, Alla; Yang, Juan; Song, Chen; Zaveri, Rahul A; Imre, Dan

    2008-01-31

    A significant fraction of atmospheric particles are composed of inorganic substances that are mixed or coated with organic compounds. The properties and behavior of these particles depend on the internal composition and arrangement of the specific constituents in each particle. It is important to know which constituent is on the surface and whether it covers the particle surface partially or entirely. We demonstrate here an instrument consisting of an ultrasensitive single-particle mass spectrometer coupled with a differential mobility analyzer to quantitatively measure in real time individual particle composition, size, density, and shape and to determine which substance is on the surface and whether it entirely covers the particle. For this study, we use NaCl particles completely coated with liquid dioctyl phthalate to generate spherical particles, and NaCl particles partially coated with pyrene, a solid poly aromatic hydrocarbon, to produce aspherical particles with pyrene nodules and an exposed NaCl core. We show that the behavior of the mass spectral intensities as a function of laser fluence yields information that can be used to determine the morphological distribution of individual particle constituents.

  10. In Situ Neutron Diffraction Analyzing Stress-Induced Phase Transformation and Martensite Elasticity in [001]-Oriented Co49Ni21Ga30 Shape Memory Alloy Single Crystals

    Science.gov (United States)

    Reul, A.; Lauhoff, C.; Krooß, P.; Gutmann, M. J.; Kadletz, P. M.; Chumlyakov, Y. I.; Niendorf, T.; Schmahl, W. W.

    2018-02-01

    Recent studies demonstrated excellent pseudoelastic behavior and cyclic stability under compressive loads in [001]-oriented Co-Ni-Ga high-temperature shape memory alloys (HT-SMAs). A narrow stress hysteresis was related to suppression of detwinning at RT and low defect formation during phase transformation due to the absence of a favorable slip system. Eventually, this behavior makes Co-Ni-Ga HT-SMAs promising candidates for several industrial applications. However, deformation behavior of Co-Ni-Ga has only been studied in the range of theoretical transformation strain in depth so far. Thus, the current study focuses not only on the activity of elementary deformation mechanisms in the pseudoelastic regime up to maximum theoretical transformation strains but far beyond. It is shown that the martensite phase is able to withstand about 5% elastic strain, which significantly increases the overall deformation capability of this alloy system. In situ neutron diffraction experiments were carried out using a newly installed testing setup on Co-Ni-Ga single crystals in order to reveal the nature of the stress-strain response seen in the deformation curves up to 10% macroscopic strain.

  11. Change in size, shape and radiocolloid uptake of the alcoholic liver during alcohol withdrawal, as demonstrated by single photon emission computed tomography

    International Nuclear Information System (INIS)

    Blomquist, L.; Yansen Wang; Jacobsson, H.; Kimiaei, S.

    1994-01-01

    The volume of the total liver and separate right and left lobes was studied before and after 1 week of alcohol withdrawal in 16 consecutive alcoholics by means of single photon emission computed tomography after intravenous injection of 99 Tc m -human albumin colloid; the relative tissue distribution of radioactivity was also followed. The left liver lobe increased in volume more than the right lobe during drinking and decreased more rapidly after alcohol withdrawal. Median volume reductions during 1 week of alcohol withdrawal were: total liver 12%, left lob 26%, and right lobe 8%, indicating that half of the reduction to values of a control group was achieved during this first week. The volume of the right but not of the left lobe was significantly correlated to body size in alcoholics and in controls. The left lobe had a lower capacity to concentrate the radiocolloid than the right lobe in alcoholics and in controls. The liver/spleen, liver/bone marrow and liver/background radioactivity concentration ratios in the alcoholics increased during alcohol withdrawal We conclude that heavy drinking causes both an increased total liver volume and a change in liver shape, with a relatively more enlarged left right lobe, as well as a decreased capacity to concentrate radiocolloid. These changes are rapidly reversible during abstinence from alcohol. (au) (26 refs.)

  12. Generation of gear tooth surfaces by application of CNC machines

    Science.gov (United States)

    Litvin, F. L.; Chen, N. X.

    1994-01-01

    This study will demonstrate the importance of application of computer numerically controlled (CNC) machines in generation of gear tooth surfaces with new topology. This topology decreases gear vibration and will extend the gear capacity and service life. A preliminary investigation by a tooth contact analysis (TCA) program has shown that gear tooth surfaces in line contact (for instance, involute helical gears with parallel axes, worm gear drives with cylindrical worms, etc.) are very sensitive to angular errors of misalignment that cause edge contact and an unfavorable shape of transmission errors and vibration. The new topology of gear tooth surfaces is based on the localization of bearing contact, and the synthesis of a predesigned parabolic function of transmission errors that is able to absorb a piecewise linear function of transmission errors caused by gear misalignment. The report will describe the following topics: description of kinematics of CNC machines with six degrees of freedom that can be applied for generation of gear tooth surfaces with new topology. A new method for grinding of gear tooth surfaces by a cone surface or surface of revolution based on application of CNC machines is described. This method provides an optimal approximation of the ground surface to the given one. This method is especially beneficial when undeveloped ruled surfaces are to be ground. Execution of motions of the CNC machine is also described. The solution to this problem can be applied as well for the transfer of machine tool settings from a conventional generator to the CNC machine. The developed theory required the derivation of a modified equation of meshing based on application of the concept of space curves, space curves represented on surfaces, geodesic curvature, surface torsion, etc. Condensed information on these topics of differential geometry is provided as well.

  13. The development of complex tooth shape in reptiles

    Czech Academy of Sciences Publication Activity Database

    Zahradníček, Oldřich; Buchtová, Marcela; Dosedělová, Hana; Tucker, A. S.

    2014-01-01

    Roč. 5, FEB 25 (2014), UNSP 74 ISSN 1664-042X Grant - others:GA ČR(CZ) GCP302/12/J059 Program:GC Institutional support: RVO:68378041 ; RVO:67985904 Keywords : odontogenesis * reptile * cusp Subject RIV: EA - Cell Biology Impact factor: 3.534, year: 2014

  14. Energy harvesting from mastication forces via a smart tooth

    Science.gov (United States)

    Bani-Hani, Muath; Karami, M. Amin

    2016-04-01

    The batteries of the current pacing devices are relatively large and occupy over 60 percent of the size of pulse generators. Therefore, they cannot be placed in the subtle areas of human body. In this paper, the mastication force and the resulting tooth pressure are converted to electricity. The pressure energy can be converted to electricity by using the piezoelectric effect. The tooth crown is used as a power autonomous pulse generator. We refer to this envisioned pulse generator as the smart tooth. The smart tooth is in the form of a dental implant. A piezoelectric vibration energy harvester is designed and modeled for this purpose. The Piezoelectric based energy harvesters investigated and analyzed in this paper initially includes a single degree of freedom piezoelectric based stack energy harvester which utilizes a harvesting circuit employing the case of a purely resistive circuit. The next step is utilizing and investigating a bimorph piezoelectric beam which is integrated/embedded in the smart tooth implant. Mastication process causes the bimorph beam to buckle or return to unbuckled condition. The transitions results in vibration of the piezoelectric beam and thus generate energy. The power estimated by the two mechanisms is in the order of hundreds of microwatts. Both scenarios of the energy harvesters are analytically modeled. The exact analytical solution of the piezoelectric beam energy harvester with Euler-Bernoulli beam assumptions is presented. The electro-mechanical coupling and the geometric nonlinearities have been included in the model for the piezoelectric beam.

  15. Detecting Gear Tooth Fatigue Cracks in Advance of Complete Fracture

    Science.gov (United States)

    Zakrajsek, James J.; Lewicki, David G.

    1996-01-01

    Results of using vibration-based methods to detect gear tooth fatigue cracks are presented. An experimental test rig was used to fail a number of spur gear specimens through bending fatigue. The gear tooth fatigue crack in each test was initiated through a small notch in the fillet area of a tooth on the gear. The primary purpose of these tests was to verify analytical predictions of fatigue crack propagation direction and rate as a function of gear rim thickness. The vibration signal from a total of three tests was monitored and recorded for gear fault detection research. The damage consisted of complete rim fracture on the two thin rim gears and single tooth fracture on the standard full rim test gear. Vibration-based fault detection methods were applied to the vibration signal both on-line and after the tests were completed. The objectives of this effort were to identify methods capable of detecting the fatigue crack and to determine how far in advance of total failure positive detection was given. Results show that the fault detection methods failed to respond to the fatigue crack prior to complete rim fracture in the thin rim gear tests. In the standard full rim gear test all of the methods responded to the fatigue crack in advance of tooth fracture; however, only three of the methods responded to the fatigue crack in the early stages of crack propagation.

  16. Tooth polishing: The current status

    Directory of Open Access Journals (Sweden)

    Madhuri Alankar Sawai

    2015-01-01

    Full Text Available Healthy teeth and gums make a person feel confident and fit. As people go about their daily routines and with different eating and drinking habits, the tooth enamel turns yellowish or gets stained. Polishing traditionally has been associated with the prophylaxis procedure in most dental practices, which patients know and expect. However, with overzealous use of polishing procedure, there is wearing of the superficial tooth structure. This would lead to more accumulation of local deposits. Also, it takes a long time for the formation of the fluoride-rich layer of the tooth again. Hence, now-a-days, polishing is not advised as a part of routine oral prophylaxis procedure but is done selectively based on the patients′ need. The article here, gives an insight on the different aspects of the polishing process along with the different methods and agents used for the same.

  17. Coping with cracked tooth syndrome.

    Science.gov (United States)

    Benenati, F W

    1996-01-01

    Cracked tooth syndrome typically poses a diagnostic challenge for the dentist. Symptoms include tenderness to biting on certain foods, often poorly localized, and occasional thermal sensitivity. Knowing where to look for this entity, especially in the mandibular molar region, can be especially helpful. Treatment of the tooth depends on the degree of pulpal involvement and the extent of the crack. Cuspal coverage is required of all cracked posterior teeth that are retainable. Root canal therapy is included if symptoms persist or if pulpal pathosis exists at the outset. Cracks extending beyond the osseous crest indicate a poor prognosis. Armed with this knowledge, the dentist can overcome many cracked tooth dilemmas, resulting in satisfaction for both patient and practitioner alike.

  18. Primary culprit for tooth loss!!

    Science.gov (United States)

    Nuvvula, Sailavanya; Chava, Vijay Kumar; Nuvvula, Sivakumar

    2016-01-01

    In order to facilitate planning for dental health services and to progress strategies to continue the reduction in tooth loss, it is important to identify the factors that result in such loss. therefore the aim of the study is to investigate the major cause for tooth extraction. to examine whether the major reason for tooth extraction is dental caries or periodontal disease. The study is carried out among the dental practitioners in our district. A questionnaire containing 10 items was distributed to the dental practitioners, which included age, gender, no of teeth indicated for extraction, the reason for extraction, and the periodontal parameters that are involved with the extracted tooth and were requested to complete the form on every extraction they were to undertake. the study form was collected at the end of the study period and data was subjected to statistical analysis. A total of 502 patients were enrolled during the study period, and a total of 1055 teeth were extracted for several reasons. we found that 51.14%extractions are due to dental caries in case of 20-30years age groups, which is more when compared to tooth loss due to periodontal diseases in this age group. whereas in case of >40years of age group periodontal diseases account for 54.11%, and dental caries accounts for only 29.11%. Showing more teeth were lost due to periodontal disease. therefore we concluded that, caries is the dominant reason for extraction in patients with 20-30 years of age while periodontal disease accounts for the majority of tooth extraction in patients older than 40 years.

  19. On gear tooth stiffness evaluation

    DEFF Research Database (Denmark)

    Pedersen, Niels Leergaard; Jørgensen, Martin Felix

    2014-01-01

    The estimation of gear stiffness is important for determining the load distribution between the gear teeth when two sets of teeth are in contact. Two factors have a major influence on the stiffness; firstly the boundary condition through the gear rim size included in the stiffness calculation...... and secondly the size of the contact. In the FE calculation the true gear tooth root profile is applied. The meshing stiffnesses of gears are highly non-linear, it is however found that the stiffness of an individual tooth can be expressed in a linear form assuming that the contact width is constant. © 2014...... Elsevier Ltd. All rights reserved....

  20. Mandibular lateral incisor with four root canals: A unique case of double tooth diagnosed using multidetector computed tomography

    International Nuclear Information System (INIS)

    Gupta, Sunil Kumar; Acharya, Shashi Rashmi; Ather, Amber; Gupta, Jaya

    2013-01-01

    Double tooth is a dental anomaly consequent to fusion of two or more teeth or gemination of a single tooth. This report describes a unique case of double tooth in relation to a mandibular lateral incisor exhibiting the presence of four root canals. The role of conventional radiography and advanced three-dimensional imaging techniques in the better assessment of complex root canal systems and their aid in endodontic management has also been highlighted.

  1. Mandibular lateral incisor with four root canals: A unique case of double tooth diagnosed using multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Sunil Kumar; Acharya, Shashi Rashmi; Ather, Amber; Gupta, Jaya [Manipal College of Dental Sciences, Manipal University, Manipal (India)

    2013-06-15

    Double tooth is a dental anomaly consequent to fusion of two or more teeth or gemination of a single tooth. This report describes a unique case of double tooth in relation to a mandibular lateral incisor exhibiting the presence of four root canals. The role of conventional radiography and advanced three-dimensional imaging techniques in the better assessment of complex root canal systems and their aid in endodontic management has also been highlighted.

  2. Proteomic analysis of human tooth pulp: proteomics of human tooth.

    Science.gov (United States)

    Eckhardt, Adam; Jágr, Michal; Pataridis, Statis; Mikšík, Ivan

    2014-12-01

    The unique pulp-dentin complex demonstrates strong regenerative potential, which enables it to respond to disease and traumatic injury. Identifying the proteins of the pulp-dentin complex is crucial to understanding the mechanisms of regeneration, tissue calcification, defense processes, and the reparation of dentin by dental pulp. The lack of knowledge of these proteins limits the development of more efficient therapies. The proteomic profile of human tooth pulp was investigated and compared with the proteome of human dentin and blood. The samples of tooth pulp were obtained from 5 sound permanent human third molars of 5 adults (n = 5). The extracted proteins were separated by 2-dimensional gel electrophoresis, analyzed by nano-liquid chromatography tandem mass spectrometry, and identified by correlating mass spectra to the proteomic databases. A total of 342 proteins were identified with high confidence, and 2 proteins were detected for the first time in an actual human sample. The identified tooth pulp proteins have a variety of functions: structural, catalytic, transporter, protease activity, immune response, and many others. In a comparison with dentin and blood plasma, 140 (pulp/dentin) shared proteins were identified, 37 of which were not observed in plasma. It can be suggested that they might participate in the unique pulp-dentin complex. This proteomic investigation of human tooth pulp, together with the previously published study of human dentin, is one of the most comprehensive proteome lists of human teeth to date. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  3. Prosthetic clone and natural human tooth comparison by speckle interferometry

    Science.gov (United States)

    Slangen, Pierre; Corn, Stephane; Fages, Michel; Raynal, Jacques; Cuisinier, Frederic J. G.

    2010-09-01

    New trends in dental prosthodontic interventions tend to preserve the maximum of "body" structure. With the evolution of CAD-CAM techniques, it is now possible to measure "in mouth" the remaining dental tissues. The prosthetic crown is then designed using this shape on which it will be glued on, and also by taking into account the contact surface of the opposite jaw tooth. Several theories discuss on the glue thickness and formulation, but also on the way to evolve to a more biocompatible crown and also new biomechanical concepts. In order to validate these new concepts and materials, and to study the mechanical properties and mechanical integrity of the prosthesis, high resolution optical measurements of the deformations of the glue and the crown are needed. Samples are two intact premolars extracted for orthodontics reasons. The reference sample has no modifications on the tooth while the second sample tooth is shaped to receive a feldspathic ceramic monoblock crown which will be glued. This crown was manufactured with a chairside CAD-CAM system from an intra-oral optical print. The software allows to realize a nearly perfect clone of the reference sample. The necessary space for the glue is also entered with ideal values. This duplication process yields to obtain two samples with identical anatomy for further processing. The glue joint thickness can also be modified if required. The purpose is to compare the behaviour of a natural tooth and its prosthetic clone manufactured with "biomechanical" concepts. Vertical cut samples have been used to deal with planar object observation, and also to look "inside" the tooth. We have developed a complete apparatus enabling the study of the compressive mechanical behaviour of the concerned tooth by speckle interferometry. Because in plane displacements are of great interest for orthodontic measurements1, an optical fiber in-plane sensitive interferometer has been designed. The fibers are wrapped around piezoelectric

  4. Life of a Tooth: A Visual Timeline

    Medline Plus

    Full Text Available ... more Children's Oral Health What is Baby Bottle Tooth Decay? What is Orofacial Pain? How Do I Care ... Is My Child at Risk for Early Childhood Tooth Decay? Learn what those dental words mean. The Life ...

  5. Life of a Tooth: A Visual Timeline

    Science.gov (United States)

    ... more Children's Oral Health What is Baby Bottle Tooth Decay? What is Orofacial Pain? How Do I Care ... Is My Child at Risk for Early Childhood Tooth Decay? Learn what those dental words mean. The Life ...

  6. Life of a Tooth: A Visual Timeline

    Medline Plus

    Full Text Available ... Child First See a Dentist? The History of Dental Advances Why is Oral Health Important for Men? What is Baby Bottle Tooth Decay? Learn what those dental words mean. The Life of a Tooth Home | ...

  7. Life of a Tooth: A Visual Timeline

    Medline Plus

    Full Text Available ... InfoBites Quick Reference Learn more Children's Oral Health What is Baby Bottle Tooth Decay? Why is Oral ... Tooth Decay? The History of Dental Advances Learn what those dental words mean. The Life of a ...

  8. The cracked tooth syndrome: an elusive diagnosis.

    Science.gov (United States)

    Türp, J C; Gobetti, J P

    1996-10-01

    The authors review the literature and present a case of cracked tooth syndrome. Special emphasis is placed on diagnostic problems associated with this syndrome. The case report demonstrates classic and atypical features of cracked tooth syndrome.

  9. Unicuspid and bicuspid tooth crown formation in squamates.

    Science.gov (United States)

    Handrigan, Gregory R; Richman, Joy M

    2011-12-15

    The molecular and developmental factors that regulate tooth morphogenesis in nonmammalian species, such as snakes and lizards, have received relatively little attention compared to mammals. Here we describe the development of unicuspid and bicuspid teeth in squamate species. The simple, cone-shaped tooth crown of the bearded dragon and ball python is established at cap stage and fixed in shape by the differentiation of cells and the secretion of dental matrices. Enamel production, as demonstrated by amelogenin expression, occurs relatively earlier in squamate teeth than in mouse molars. We suggest that the early differentiation in squamate unicuspid teeth at cap stage correlates with a more rudimentary tooth crown shape. The leopard gecko can form a bicuspid tooth crown despite the early onset of differentiation. Cusp formation in the gecko does not occur by the folding of the inner enamel epithelium, as in the mouse molar, but by the differential secretion of enamel. Ameloblasts forming the enamel epithelial bulge, a central swelling of cells in the inner enamel epithelium, secrete amelogenin at cap stage, but cease to do so by bell stage. Meanwhile, other ameloblasts in the inner enamel epithelium continue to secrete enamel, forming cusp tips on either side of the bulge. Bulge cells specifically express the gene Bmp2, which we suggest serves as a pro-differentiation signal for cells of the gecko enamel organ. In this regard, the enamel epithelial bulge of the gecko may be more functionally analogous to the secondary enamel knot of mammals than the primary enamel knot. Copyright © 2011 Wiley Periodicals, Inc., A Wiley Company.

  10. Sexual dimorphism in tooth morphometrics: An evaluation of the parameters.

    Science.gov (United States)

    Banerjee, Abhishek; Kamath, Venkatesh V; Satelur, Krishnanand; Rajkumar, Komali; Sundaram, Lavanya

    2016-01-01

    Sexual dimorphism refers to the variations in tooth size and shape between the sexes. The consistency of these variations is valuable in the identification of the sex of an individual in times of mass disaster when whole body parts get destroyed or are unavailable. There exist differences in the expression of these variables across races and regions. This study aims to tabulate and identify the variations in tooth measurements using standarized reference points in an attempt to establish parameters of sexual dimorphism. 100 individuals (50 of each sex) in the age group 19-23 years were assessed for standard morphometric parameters of the maxillary central incisor, canine, premolar and molar. Odontometric measurements of established parameters were recorded from impression casts of the maxillary jaws. The mesiodistal width (MDW), the bucco-ligual width (BLW), the crown length (CL) and the cervical angle (CA) were charted among the teeth. The consistency of the variations was statistically analyzed and a logistic regression table was prepared to identify the sex of the individual from the tooth measurements. The BLW, MDW and CL reflected significant variations among all the teeth to be effective in establishing sexual dimorphism. CA as a parameter was inadequate across all the teeth. The permanent maxillary canine was the most important tooth to be reflective of the gender and statistically significant to be utilized for gender determination.

  11. A wheel-shaped single-molecule magnet of [MnII 3MnIII 4]: quantum tunneling of magnetization under static and pulse magnetic fields.

    Science.gov (United States)

    Koizumi, Satoshi; Nihei, Masayuki; Shiga, Takuya; Nakano, Motohiro; Nojiri, Hiroyuki; Bircher, Roland; Waldmann, Oliver; Ochsenbein, Stefan T; Güdel, Hans U; Fernandez-Alonso, Felix; Oshio, Hiroki

    2007-01-01

    The reaction of N-(2-hydroxy-5-nitrobenzyl)iminodiethanol (=H3(5-NO2-hbide)) with Mn(OAc)2* 4 H2O in methanol, followed by recrystallization from 1,2-dichloroethane, yielded a wheel-shaped single-molecule magnet (SMM) of [MnII 3MnIII 4(5-NO2-hbide)6].5 C2H4Cl2 (1). In 1, seven manganese ions are linked by six tri-anionic ligands and form the wheel in which the two manganese ions on the rim and the one in the center are MnII and the other four manganese ions are MnIII ions. Powder magnetic susceptibility measurements showed a gradual increase with chimT values as the temperature was lowered, reaching a maximum value of 53.9 emu mol(-1) K. Analyses of magnetic susceptibility data suggested a spin ground state of S=19/2. The zero-field splitting parameters of D and B 0 4 were estimated to be -0.283(1) K and -1.64(1)x10(-5) K, respectively, by high-field EPR measurements (HF-EPR). The anisotropic parameters agreed with those estimated from magnetization and inelastic neutron scattering experiments. AC magnetic susceptibility measurements showed frequency-dependent in- and out-of-phase signals, characteristic data for an SMM, and an Arrhenius plot of the relaxation time gave a re-orientation energy barrier (DeltaE) of 18.1 K and a pre-exponential factor of 1.63x10(-7) s. Magnetization experiments on aligned single crystals below 0.7 K showed a stepped hysteresis loop, confirming the occurrence of quantum tunneling of the on magnetization (QTM). QTM was, on the other hand, suppressed by rapid sweeps of the magnetic field even at 0.5 K. The sweep-rate dependence of the spin flips can be understood by considering the Landau-Zener-Stückelberg (LZS) model.

  12. An experimental study on single phase convection heat transfer and pressure drop in two brazed plate heat exchangers with different chevron shapes and hydraulic diameters

    International Nuclear Information System (INIS)

    Kim, Man Bae; Park, Chang Yong

    2017-01-01

    An experimental study on heat transfer and pressure drop characteristics was performed at single phase flow in two Brazed plate heat exchangers (BPHEs) with different geometries. The corrugation density of one of the BPHE (Type II) was two times as high as that of the other BPHE (Type I). The hydraulic diameter of the type II BPHE was 2.13 mm, which was 38 % smaller than that of the type I BPHE. Also, the cross section shape of the flow channels for the type II BPHE was different from that for conventional BPHEs due to the unusual corrugation patterns and brazing points. The experimental conditions for temperatures were varied from 4.6 °C to 49.1 °C, and for mass flow rates were changed from 0.07 kg/s to 1.24 kg/s. The measured results showed that pressure drop in the type II BPHE was about 110 % higher than that in the type I BPHE. Nu of the type II was higher than that of the type I BPHE and the enhancement became larger with the increase of Re at the ranges above 800. New correlations for fF and Nu were proposed by this study and their prediction accuracy could be improved by considering the surface enlargement factor in the correlations. The performance evaluation of the two BPHEs was performed by (j/f F 1 /3 ) which represented the ratio of heat transfer and pressure drop performance. Also, a new parameter, the capacity compactness of PHE, was proposed and it presented the PHE capacity per unit volume and unit log mean temperature difference. The comparison showed that the two BPHEs had similar values of the (j/f F 1 /3 ), whereas they had significantly different values of the capacity compactness. The capacity compactness of the type II BPHE was 1.5 times higher than that for the type I BPHE.

  13. Multiphoton microscopy imaging of developing tooth germs

    Directory of Open Access Journals (Sweden)

    Pei-Yu Pan

    2014-01-01

    Conclusion: In this study, a novel multiphoton microscopy database of images from developing tooth germs in mice was set up. We confirmed that multiphoton laser microscopy is a powerful tool for investigating the development of tooth germ and is worthy for further application in the study of tooth regeneration.

  14. AUTOGENOUS TOOTH TRANSPLANTATION IN ADULT ...

    African Journals Online (AJOL)

    drclement

    ABSTRACT. A case of autotransplantation of a tooth in a 26 year old female African cleft palate patient is reported. This case report emphasizes the possibility and success of autotransplantation in our centre, it also emphasizes that transplantation is only technique sensitive but less equipment sensitive. It further stresses.

  15. Stem cells for tooth engineering

    Directory of Open Access Journals (Sweden)

    G Bluteau

    2008-07-01

    Full Text Available Tooth development results from sequential and reciprocal interactions between the oral epithelium and the underlying neural crest-derived mesenchyme. The generation of dental structures and/or entire teeth in the laboratory depends upon the manipulation of stem cells and requires a synergy of all cellular and molecular events that finally lead to the formation of tooth-specific hard tissues, dentin and enamel. Although mesenchymal stem cells from different origins have been extensively studied in their capacity to form dentin in vitro, information is not yet available concerning the use of epithelial stem cells. The odontogenic potential resides in the oral epithelium and thus epithelial stem cells are necessary for both the initiation of tooth formation and enamel matrix production. This review focuses on the different sources of stem cells that have been used for making teeth in vitro and their relative efficiency. Embryonic, post-natal or even adult stem cells were assessed and proved to possess an enormous regenerative potential, but their application in dental practice is still problematic and limited due to various parameters that are not yet under control such as the high risk of rejection, cell behaviour, long tooth eruption period, appropriate crown morphology and suitable colour. Nevertheless, the development of biological approaches for dental reconstruction using stem cells is promising and remains one of the greatest challenges in the dental field for the years to come.

  16. Charcot-Marie-Tooth Disease

    Science.gov (United States)

    Charcot-Marie-Tooth disease (CMT) is a group of genetic nerve disorders. It is named after the three doctors who first identified it. ... a nerve biopsy. There is no cure. The disease can be so mild you don't realize ...

  17. Diagnosis of cracked tooth syndrome

    Directory of Open Access Journals (Sweden)

    Sebeena Mathew

    2012-01-01

    Full Text Available The incidences of cracks in teeth seem to have increased during the past decade. Dental practitioners need to be aware of cracked tooth syndrome (CTS in order to be successful at diagnosing CTS. Early diagnosis has been linked with successful restorative management and predictably good prognosis. The purpose of this article is to highlight factors that contribute to detecting cracked teeth.

  18. Diagnosis of cracked tooth syndrome.

    Science.gov (United States)

    Mathew, Sebeena; Thangavel, Boopathi; Mathew, Chalakuzhiyil Abraham; Kailasam, Sivakumar; Kumaravadivel, Karthick; Das, Arjun

    2012-08-01

    The incidences of cracks in teeth seem to have increased during the past decade. Dental practitioners need to be aware of cracked tooth syndrome (CTS) in order to be successful at diagnosing CTS. Early diagnosis has been linked with successful restorative management and predictably good prognosis. The purpose of this article is to highlight factors that contribute to detecting cracked teeth.

  19. Diagnosis of cracked tooth syndrome

    OpenAIRE

    Mathew, Sebeena; Thangavel, Boopathi; Mathew, Chalakuzhiyil Abraham; Kailasam, SivaKumar; Kumaravadivel, Karthick; Das, Arjun

    2012-01-01

    The incidences of cracks in teeth seem to have increased during the past decade. Dental practitioners need to be aware of cracked tooth syndrome (CTS) in order to be successful at diagnosing CTS. Early diagnosis has been linked with successful restorative management and predictably good prognosis. The purpose of this article is to highlight factors that contribute to detecting cracked teeth.

  20. Leukotrienes in orthodontic tooth movement.

    Science.gov (United States)

    Mohammed, A H; Tatakis, D N; Dziak, R

    1989-03-01

    Prostaglandins (PGs) and leukotrienes (LTs) are products of arachidonic acid conversion. PGs have an established role in mediating orthodontic tooth movement. The role of LTs in modulating or mediating orthodontic tooth movement was investigated in this study. One hundred thirty-two Sprague-Dawley rats were used; the animals weighed 300 to 400 gm with equal numbers of male and female rats. They were divided into five main groups of 24 animals each and a sham group of 12 animals. An orthodontic appliance was placed and activated on all the animals except the sham group; in this group the appliances were not active. Each main group was given one of the following treatments daily: distilled water, 5% gum arabic solution, PG synthesis inhibitor indomethacin, LT synthesis inhibitor AA861, and a combination of both drugs. Each group was divided into six subgroups of four animals; the animals were killed at either 1, 3, 5, 7, 10, or 14 days, and tooth movement measured. The three sham subgroups received distilled water and were killed at 1, 7, or 10 days. The first maxillary molar (the moved tooth) and surrounding tissues were removed from all animals in the sham group and the subgroups killed at 1, 7, and 10 days in the gum arabic solution group and the LT synthesis inhibitor group. Prostaglandin E2 (PGE2) and leukotriene B4 (LTB4) were extracted, measured with radioimmunoassay (RIA), and standardized per milligram of protein in the sample. A significant inhibition of tooth movement occurred beginning on day 7 in the indomethacin, AA861, and combination groups; there was no significant difference among these groups.(ABSTRACT TRUNCATED AT 250 WORDS)

  1. Proteomic Analysis of Human Tooth Pulp: Proteomics of Human Tooth

    Czech Academy of Sciences Publication Activity Database

    Eckhardt, Adam; Jágr, Michal; Pataridis, Statis; Mikšík, Ivan

    2014-01-01

    Roč. 40, č. 12 (2014), s. 1961-1966 ISSN 0099-2399 R&D Projects: GA ČR(CZ) GA13-17224S; GA ČR(CZ) GAP206/12/0453; GA MZd(CZ) NT14324 Institutional support: RVO:67985823 Keywords : dentin * human pulp * tandem mass spectrometry * tooth proteome * 2-dimensional gel electrophoresis Subject RIV: FF - HEENT, Dentistry Impact factor: 3.375, year: 2014

  2. Photometric assessment of tooth color using commonly available software.

    Science.gov (United States)

    Denissen, Harry; Dozic, Alma

    2010-01-01

    It would be expedient to develop a simple digital procedure for matching shade guides to teeth for dental restorations. It was hypothesized that precise and objective L*a*b* measurements could be performed on photographic images of teeth and shade guides using commonly available photo software. Tooth shade guide tabs, shaped like computer-generated posterior crowns, were used for color matching. Digital photographs were obtained of the vestibular surface of the tooth and the neighboring shade guide. Sections of the tooth and shade guide on the photograph were cropped and analyzed in Photoshop CS2. The precision error of the measurements was expressed as the coefficient of variation in percent. The effects of tolerance setting and number of measurements and analysts were evaluated. The difference in color was calculated as the DeltaE L*a*b*. The precision errors of the L*a*b* measurements with a tolerance setting of 6 pixels were better than 1.3%. There was no significant difference between one and five repeated measurements or between the measurements and the precision errors of two analysts. Color differences (DeltaE) between repeated measurements were below 0.5 units, thus reproducible and visually identical. DeltaE L*a*b* calculations were expedient for matching a particular color guide tab to the neighboring tooth. The color coordinates L*a*b* of teeth and shade guides can be calculated with a precision error of only 1.3%, using readily available software. A tolerance setting of 6 pixels is optimal and only one measurement and one analyst are necessary for objective and precise measurements. The described digital L*a*b* measurements on a photograph offer the dentist and the ceramist a simple, precise, and objective tool for matching tooth and shade guide.

  3. Fluoridation and tooth wear in Irish adults.

    LENUS (Irish Health Repository)

    Burke, F M

    2010-10-01

    The aim of this study was to determine the prevalence of tooth wear in adults in Ireland and its relationship with water fluoridation. The National Survey of Adult Oral Health was conducted in 2000\\/2001. Tooth wear was determined using a partial mouth examination assessing the upper and lower anterior teeth. A total of 2456 subjects were examined. In this survey, increasing levels and severity of tooth wear were associated with ageing. Men were more affected by tooth wear and were more likely to be affected by severe tooth wear than women. It was found that age, and gender were significant predictors of tooth wear (P < 0.01). Overall, there was no significant relationship between fluoridation and tooth wear in this study.

  4. Single particle chemical composition and shape of fresh and aged Saharan dust in Morocco and at Cape Verde Islands during SAMUM I and II

    Science.gov (United States)

    Kandler, K.; Lieke, K.; Schütz, L.; Deutscher, C.; Ebert, M.; Jaenicke, R.; Müller-Ebert, D.; Weinbruch, S.

    2009-04-01

    The Saharan Mineral Dust Experiment (SAMUM) is focussed to the understanding of the radiative effects of mineral dust. During the SAMUM 2006 field campaign at Tinfou, southern Morocco, chemical and mineralogical properties of fresh desert aerosols were measured. The winter campaign of Saharan Mineral Dust Experiment II was based in Praia, Island of Santiago, Cape Verde. This second field campaign was dedicated to the investigation of transported Saharan Mineral Dust. Aerosol particles between 100 nm and 500 μm (Morocco) respectively 50 μm (Cape Verde) in diameter were collected by nozzle and body impactors and in a sedimentation trap. The particles were investigated by electron microscopic single particle analysis and attached energy-dispersive X-ray analysis. Chemical properties as well as size and shape for each particle were recorded. Three size regimes are identified in the aerosol at Tinfou: Smaller than 500 nm in diameter, the aerosol consists of sulfates and mineral dust. Larger than 500 nm up to 50 μm, mineral dust dominates, consisting mainly of silicates, and - to a lesser extent - carbonates and quartz. Larger than 50 μm, approximately half of the particles consist of quartz. Time series of the elemental composition show a moderate temporal variability of the major compounds. Calcium-dominated particles are enhanced during advection from a prominent dust source in Northern Africa (Chott El Djerid and surroundings). At Praia, the boundary layer aerosol consists of a superposition of mineral dust, marine aerosol and ammonium sulfate, soot, and other sulfates as well as mixtures thereof. During low-dust periods, the aerosol is dominated by sea salt. During dust events, mineral dust takes over the majority of the particle mass up to 90 %. Particles smaller 500 nm in diameter always show a significant abundance of ammonium sulfate. The particle aspect ratio was measured for all analyzed particles. Its size dependence reflects that of the chemical

  5. Replacement of missing tooth in esthetic zone with implant-supported fixed prosthesis

    Directory of Open Access Journals (Sweden)

    Sunil Kumar Mishra

    2017-01-01

    Full Text Available In the anterior region, the common reason for tooth loss is due to traumatic injury or congenital anomaly. Loss of a single tooth may cause functional and esthetic deficits to the patient. There are different treatment options available for replacing a missing incisor. Implant dentistry should be considered as first treatment alternative for replace a missing tooth. This case report presents the replacement of a missing maxillary left central incisor in a compromised site with dental implants along with bone graft followed by frenectomy to obtain a good clinical result and for better function and esthetics of the patient.

  6. Micro-tensile bond strength of sound and caries-affected primary tooth dentin measured with original designed jig.

    Science.gov (United States)

    Hosoya, Yumiko; Kawada, Eiji; Ushigome, Toshiaki; Oda, Yutaka; Garcia-Godoy, Franklin

    2006-05-01

    To measure the micro-tensile bond strength (MTBS) on sound and caries-affected primary tooth dentin using an original designed jig that was developed for making symmetric and uniformly-sized specimens for the micro-tensile strength testing. The MTBS of dumbbell-shaped specimens and matchstick-shaped specimens were measured. Dumbbell-shaped specimens: The occlusal surfaces of 15 sound primary molars were ground with a water-cooled air turbine using a diamond bur. The adhesive systems and resin-based composites were Clearfil SE Bond and Clearfil AP-X (SE group) and Single Bond and Z250 (SB group). Matchstick-shaped specimens: Sixteen primary molars (5 sound and 11 carious) were used. The occlusal surfaces of sound teeth were ground with a water-cooled air turbine using a diamond bur. Infected dentin was determined by a caries detecting dye solution and removed with a round-shaped steel bur under water-cooling and with a hand instrument. SE was applied. Data was statistically analyzed using ANOVA and Fisher's PLSD at p < 0.05. The MTBSs (MPa) for the dumbbell-shaped specimens were 8.9 +/- 7.0 in the SE group and 10.3 +/- 5.8 in the SB group and that for the matchstick-shaped specimens were 9.0 +/- 6.3 in the sound-SE group and 9.2 +/- 5.8 in the carious-SE group. No significant difference was observed among them. (c) 2005 Wiley Periodicals, Inc.

  7. Towards tooth friendly soft drinks.

    Science.gov (United States)

    Kolahi, Jafar; Fazilati, Mohamad; Kadivar, Mahdi

    2009-10-01

    Most soft drinks contain high concentration of simple carbohydrates and have a pH of 3 or even lower. Therefore, they are harmful for tooth structure. A tooth friendly soft drink (T.F.S.D) should have the following characteristics and elements; fluoride (approximately 1 ppm), casein phosphopeptide-amorphous calcium phosphate (2%), xylitol (4-6g/serving), tea polyphenols (2-4 mg/ml), cranberry extract (250 mg/ml of the flavonoids quercetin and myricetin), sugar free, pH close to 5.5 and super oxygenation (240,000 ppm) vs. carbonation. T.F.S.D can be packaged in a container which gaseous oxygen is dissolved in a liquid in the form of bubbles. However, looking at opportunities for so-called sophisticated soft drinks, T.F.S.D will be an example for a functional and health oriented soft drink.

  8. Pink tooth phenomenon: an enigma?

    Science.gov (United States)

    Thapar, Raveena; Choudhry, Swati; Sinha, Anju; Bali, Ruchita; Shukla, Deepika

    2013-10-01

    The appearance of pink teeth is a common phenomenon which has been observed after death in certain circumstances on post-mortem examination. Extra fibrinolytic activity of pulp facilitates rapid breakdown of red blood cells and diffusion of hemoglobin and its derivatives to flow into dentine. We reviewed various studies on pink tooth phenomenon which have stated the various factors that lead to pink tooth formation. Most of the authors have stressed that post-mortem pink teeth must not be considered as a reliable odontological parameter for determining cause of death. No correlation has been found between the occurrence of pink teeth and the cause of death but condition of the surroundings certainly plays an important role in the development of this phenomenon. This paper reviews the factors and conditions responsible for formation of pink teeth. Copyright © 2013 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  9. The exchangeability of shape

    Directory of Open Access Journals (Sweden)

    Kaba Dramane

    2010-10-01

    Full Text Available Abstract Background Landmark based geometric morphometrics (GM allows the quantitative comparison of organismal shapes. When applied to systematics, it is able to score shape changes which often are undetectable by traditional morphological studies and even by classical morphometric approaches. It has thus become a fast and low cost candidate to identify cryptic species. Due to inherent mathematical properties, shape variables derived from one set of coordinates cannot be compared with shape variables derived from another set. Raw coordinates which produce these shape variables could be used for data exchange, however they contain measurement error. The latter may represent a significant obstacle when the objective is to distinguish very similar species. Results We show here that a single user derived dataset produces much less classification error than a multiple one. The question then becomes how to circumvent the lack of exchangeability of shape variables while preserving a single user dataset. A solution to this question could lead to the creation of a relatively fast and inexpensive systematic tool adapted for the recognition of cryptic species. Conclusions To preserve both exchangeability of shape and a single user derived dataset, our suggestion is to create a free access bank of reference images from which one can produce raw coordinates and use them for comparison with external specimens. Thus, we propose an alternative geometric descriptive system that separates 2-D data gathering and analyzes.

  10. Optical spectroscopy and tooth decay

    Science.gov (United States)

    Misra, P.; De, T.; Singh, R.

    2005-11-01

    Optical spectroscopy in the ultraviolet, visible and mid-infrared spectral regions has been used to discriminate between healthy and diseased teeth of patients in the age range 15-75 years. Spectral scans of absorbance versus wavenumber and fluorescence intensity versus wavelength have been recorded and investigated for caries and periodontal disease. Such optical diagnostics can prove very useful in the early detection and treatment of tooth decay.

  11. Charcot-Marie-Tooth disease.

    LENUS (Irish Health Repository)

    Reilly, Mary M

    2011-03-01

    Charcot-Marie-Tooth (CMT) disease is the commonest inherited neuromuscular disorder affecting at least 1 in 2,500. Over the last two decades, there have been rapid advances in understanding the molecular basis for many forms of CMT with more than 30 causative genes now described. This has made obtaining an accurate genetic diagnosis possible but at times challenging for clinicians. This review aims to provide a simple, pragmatic approach to diagnosing CMT from a clinician\\'s perspective.

  12. Single particle chemical composition, state of mixing and shape of fresh and aged Saharan dust in Morocco and at Cape Verde Islands during SAMUM I and II

    Science.gov (United States)

    Kandler, Konrad; Emmel, Carmen; Ebert, Martin; Lieke, Kirsten; Müller-Ebert, Dörthe; Schütz, Lothar; Weinbruch, Stephan

    2010-05-01

    mixtures of these components. During low-dust periods, the aerosol is dominated by sea salt. During dust events, mineral dust dominates the particle mass (more than 90 %). Particles smaller 500 nm in diameter always show a significant abundance of ammonium sulfate. Comparing a high dust period at Cape Verde with the total data from Morocco, it is found that the atomic ratio distributions of Al/Si, K/Si and Fe/Si for the single particles are very similar for the dust component. This indicates that the dominating silicate minerals are the same. In contrast, the content of calcium rich minerals at Cape Verde is significantly lower than in Morocco which is in agreement with the source regions for the Cape Verde dust (E Mali and W Niger) derived from trajectory analysis. The sulfur content of super-micron aerosol particles at Cape Verde scales with the particle surface, indicating the presence of sulfate coatings. For the submicron particles, the sulfur content scales with particle volume, which can be attributed to the large amount of particles identified as ammonium sulfate. In contrast to findings in Japan (Zhang et al., 2006), no internal mixtures between pristine seasalt and mineral dust are present during this dust period at Cape Verde. However, for a significant number of particles a small amount of sodium and chlorine is associated with internal mixtures of dust and sulfate, what may indicate that these particles started as internal mixture of dust with a sea water droplet before taking up more sulfur from the gas phase. In general, the shape of the particles in Morocco and Cape Verde is rather similar: The distributions of the two-dimensional aspect ratio of an ellipse fitted to each particle's shape for the total aerosol show no significant differences. A median value of 1.6 is found for both locations. References Kandler, K., Schütz, L., Deutscher, C., Hofmann, H., Jäckel, S. and co-authors 2009. Tellus 61B, 32-50. Zhang, D., Iwasaka, Y., Matsuki, A., Ueno, K. and

  13. Treatment of Necrotic Calcified Tooth Using Intentional Replantation Procedure

    Directory of Open Access Journals (Sweden)

    Nima Moradi Majd

    2014-01-01

    Full Text Available Introduction. If the teeth are impacted by a chronic irritant, the pulp space possibly will undergo calcific changes that may impede access opening during root canal treatment. In such cases that conventional endodontic treatment is impossible or impractical, intentional replantation may be considered as a last solution to preserve the tooth. Methods. After failing to perform conventional root canal therapy for a necrotic calcified right mandibular second premolar, the tooth was gently extracted. The root apex was resected and the root end cavity was prepared and filled with calcium enriched mixture (CEM cement. Then, the extracted tooth was replanted in its original position. Results. After a year the tooth was asymptomatic, and the size of periapical radiolucency was remarkably reduced and no clinical sign of ankylosis was observed. Conclusion. Intentional replantation of the necrotic calcified teeth could be considered as an alternative to teeth extraction, especially for the single-rooted teeth and when nonsurgical and surgical endodontic procedures seem impossible.

  14. Protection and Reinforcement of Tooth Structures by Dental Coating Materials

    Directory of Open Access Journals (Sweden)

    Toru Nikaido

    2012-10-01

    Full Text Available It has been proposed that a resin coating can serve as a means to protect dental structure after preparation of the tooth for indirect restorations, sealing the exposed dentin. The resin coating is applied on the cut surfaces immediately after tooth preparation and before making an impression by assembling a dentin bonding system and a flowable composite. Resin coatings minimize pulp irritation and improve the bond strength between a resin cement and tooth when bonding the restoration to tooth. Recently, thin-film coating dental materials based on all-in-one adhesive technology were introduced for resin coating of indirect restorations. The thin coating materials are applied in a single clinical step and create a barrier-like film layer on the prepared dentin. The thin coatings play an important role in protecting the dentin from physical, chemical, and biological irritation. In addition, these thin-film coating materials reportedly prevent marginal leakage beneath inlays or crown restorations. In light of the many benefits provided by such a protective layer, these all-in-one adhesive materials may therefore also have the potential to cover exposed root dentin surfaces and prevent caries formation. In this paper, recent progress of the dental coating materials and their clinical applications are reviewed.

  15. Consideration of Moving Tooth Load in Gear Crack Propagation Predictions

    Science.gov (United States)

    Lewicki, David G.; Handschuh, Robert F.; Spievak, Lisa E.; Wawrzynek, Paul A.; Ingraffea, Anthony R.

    2001-01-01

    Robust gear designs consider not only crack initiation, but crack propagation trajectories for a fail-safe design. In actual gear operation, the magnitude as well as the position of the force changes as the gear rotates through the mesh. A study to determine the effect of moving gear tooth load on crack propagation predictions was performed. Two-dimensional analysis of an involute spur gear and three-dimensional analysis of a spiral-bevel pinion gear using the finite element method and boundary element method were studied and compared to experiments. A modified theory for predicting gear crack propagation paths based on the criteria of Erdogan and Sih was investigated. Crack simulation based on calculated stress intensity factors and mixed mode crack angle prediction techniques using a simple static analysis in which the tooth load was located at the highest point of single tooth contact was validated. For three-dimensional analysis, however, the analysis was valid only as long as the crack did not approach the contact region on the tooth.

  16. Primary double tooth with partial anodontia of permanent dentition: a case report

    OpenAIRE

    Prasad Rao, V. Arun; Reddy, N.Venugopal; Krishnakumar, R.; Sugumaran, D.K.; Mohan, G.; Senthil Eagappan, A.R.

    2010-01-01

    Dental anomalies of number and forms may occur in the primary and permanent dentition. Various terms have been used to describe dental twinning anomalies: gemination, fusion, concrescence, double teeth, cojoined teeth, twinned teeth, geminifusion and vicinifusion. Double tooth is a term used to describe connate tooth and includes both dental fusion and gemination. The phenomenon of gemination occurs when two teeth develop from one single bud leading to a larger...

  17. Tooth eruption and browridge formation.

    Science.gov (United States)

    Russell, M D

    1982-05-01

    One of the most reasonable hypotheses regarding the functional significance of the browridge is that the supraorbital torus forms in response to masticatory stress during development. Oyen, Walker, and Rice (1979) have recently proposed a model that tests this hypothesis: if browridges are functionally related to masticatory stresses on the cranial vault, then changes in the biomechanics of the masticatory system ought to be reflected by changes in the browridge. To test their model they attempted to relate biomechanical discontinuities resulting from tooth eruption to episodes of bone deposition on the supraorbital tori of a developmental series of dry Papio crania. This paper reports on a parallel test of the model on a cross-sectional sample of Australian Aboriginal juvenile crania. This sample showed no relation between tooth eruption and the supraorbital surface morphology thought to be indicative of active bone deposition. It is also demonstrated that no significant relationship between tooth eruption and episodes of bone deposition is shown by the Papio sample. It is concluded that the use of small cross-sectional samples of dry crania does not provide a valid test of the model.

  18. Tooth brushing for oral prophylaxis

    Directory of Open Access Journals (Sweden)

    Haruaki Hayasaki, DDS, PhD

    2014-08-01

    Full Text Available Control of plaque and debris is essential for the prevention of inflammatory periodontal diseases and dental caries, because plaque is the primary etiological factor in the introduction and development of both of these infection-oriented diseases. Plaque removal with a toothbrush is the most frequently used method of oral hygiene. Powered toothbrushes were developed beginning in the 1960s and are now widely used in developed countries. The bristles of a toothbrush should be able to reach and clean efficiently most areas of the mouth, and recently the design of both manual and powered toothbrushes has focused on the ability to reach and clean interproximal tooth surfaces. An individual's tooth brushing behavior, including force, duration, motivation and motion, are also critical to tooth brushing efficacy. Dental floss and the type of toothpaste play additional important roles as auxiliary tools for oral prophylaxis. Dental professionals should help their care-receivers’ meet the requirements of oral hygiene to maintain their QOL. This article reviews these topics.

  19. Molecular Genetics of Supernumerary Tooth Formation

    Science.gov (United States)

    Wang, Xiu-Ping; Fan, Jiabing

    2011-01-01

    Summary Despite advances in the knowledge of tooth morphogenesis and differentiation, relatively little is known about the aetiology and molecular mechanisms underlying supernumerary tooth formation. A small number of supernumerary teeth may be a common developmental dental anomaly, while multiple supernumerary teeth usually have a genetic component and they are sometimes thought to represent a partial third dentition in humans. Mice, which are commonly used for studying tooth development, only exhibit one dentition, with very few mouse models exhibiting supernumerary teeth similar to those in humans. Inactivation of Apc or forced activation of Wnt/β(catenin signalling results in multiple supernumerary tooth formation in both humans and in mice, but the key genes in these pathways are not very clear. Analysis of other model systems with continuous tooth replacement or secondary tooth formation, such as fish, snake, lizard, and ferret, is providing insights into the molecular and cellular mechanisms underlying succesional tooth development, and will assist in the studies on supernumerary tooth formation in humans. This information, together with the advances in stem cell biology and tissue engineering, will pave ways for the tooth regeneration and tooth bioengineering. PMID:21309064

  20. [Assessment of tooth bleaching efficacy with spectrophotometer].

    Science.gov (United States)

    Zhu, Wenhao; Liu, Chang; Pan, Jie

    2014-06-01

    To analyze the changes in CIE L*, a*, and b* at cervical, body, and incisal sites after tooth bleaching by using a spectrophotometer. Sixty-seven intact and healthy maxillary central incisors were in-vestigated. These incisors were darker than A3 according to the Vita Classical shade guide. The CIE tooth shade parameters L*, a*, and b* were simultaneously recorded at three tooth areas (cervical, body, and incisal) with a spectrophotometer before and after tooth bleaching (35%H2O2 coordinating with Beyond whitening accelerator irradiating). The shade dif-ferential (DeltaE) was calculated. ANOVA, paired t-test, and Pearson correlation analysis were used for data analysis. The efficacy rates of tooth bleaching were satisfactory, with 86.6%, 86.6%, and 85.1% in the cervical, body, and incisal sites, respectively. The average values of DeltaE were 5.09, 4.44, and 4.40 in the cervical, body, and incisal sites. Tooth bleaching significantly increased L* and significantly decreased a* and b* in all tooth areas (P spectrophotometer could objectively evaluate the whitening effect of tooth bleaching at the different tooth sites. The tooth bleaching system (35%H202 coordinating with Beyond whitening accelerator irradiating) exerts powerful bleaching actions in most of the tooth areas investigated. The order of tooth bleaching effectiveness is cervicalbody>incisal. Yellow coloration is decreased mainly at the cervical site, and brightness was increased mostly at theincisal site. The effectiveness of tooth bleaching increases as the baseline b* value increases.

  1. Protocolo protésico - quirúrgico en temporización inmediata de dientes unitarios, utilizando una cubeta multifuncional desmontable Prosthetic protocol - surgery in the immediate temporization of a single tooth using a multifunctional removable tray

    Directory of Open Access Journals (Sweden)

    Y Leighton

    2010-04-01

    estudio, la fusión de ambos procedimientos brinda una alternativa de tratamiento segura, predecible, rápida y de fácil ejecución para el clínico, permitiendo la temporización inmediata de implantes. Reporte de técnica.Purpose: This clinical report is the description of a prosthetic protocol - surgery which allows direct visualization of the operative site and the correct positioning of the prosthetic-implantation of a screw retained temporary crown constructed immediately following the insertion of the implant. Methods: 10 patients, whose main inclusion criterion was having a partially edentulous posterior unit with an opposing natural tooth, were selected from the specialized program of Maxillofacial Implantology at the University of Chile. As diagnostic protocol was requested, laboratory tests, radiographic examinations and impressions of dental arches were recorded in order to obtain plaster models for the study and which were positioned in a semi-adjustable articulator type Whip Mix, which produced a diagnostic wax-up tooth replacement, free of occlusal contact in the maximal intercuspal (MIC and mandibular excursions. Based on the diagnostic wax-up one can design a multi-functional removable tray (U. de Chile, whose key feature is that it merges a surgical guide and a prosthetic assembly guide for the correct immediate temporization. The procedure starts with a full thickness flap positioned in the mouth of the multi-functional guide of the surgical phase to allow the implant site drilling and implant insertion. The surgical site is sutured with black braided silk and you immediately draw up the screw retained temporary crown using the multi-functional guide in the prosthetic loading phase. Results: A total of 12 Renova Tapered implants (Lifecore were installed using the multi-functional tray which provided the direction of the drilling and construction of its acrylic- resin temporary crowns without segmented screws. Conclusions: With the limitations of this

  2. Mechanisms of tooth eruption and orthodontic tooth movement.

    Science.gov (United States)

    Wise, G E; King, G J

    2008-05-01

    Teeth move through alveolar bone, whether through the normal process of tooth eruption or by strains generated by orthodontic appliances. Both eruption and orthodontics accomplish this feat through similar fundamental biological processes, osteoclastogenesis and osteogenesis, but there are differences that make their mechanisms unique. A better appreciation of the molecular and cellular events that regulate osteoclastogenesis and osteogenesis in eruption and orthodontics is not only central to our understanding of how these processes occur, but also is needed for ultimate development of the means to control them. Possible future studies in these areas are also discussed, with particular emphasis on translation of fundamental knowledge to improve dental treatments.

  3. Diagnosis and treatment planning: cracked tooth.

    Science.gov (United States)

    Rivera, Eric M; Williamson, Anne

    2003-03-01

    This article discusses the cracked tooth, one of the five major classifications of longitudinal tooth fractures: 1) craze line; 2) cuspal fracture; 3) cracked tooth; 4) split tooth; and 5) vertical root fracture. The term "longitudinal tooth fracture" was first introduced by Rivera (Personal Communication, Iowa City, IA, 1996) and has two meanings. The first implies distance (length), particularly in the vertical (occlusal-cervical) plane, as illustrated by longitudinal lines on a map. The second indicates that these fractures occur over a period of time. Therefore, the term longitudinal tooth fracture applies to fractures that have both a distance and a time component. Thus, fractures are described that are not related to impact trauma (which occurs primarily in incisors), in which the distance (length) component may be similar, but is immediate instead of over a period of time.

  4. Test Tube Tooth: The Next Big Thing.

    Science.gov (United States)

    Yadav, Preeti; Tahir, Mohammed; Yadav, Harsh; Sureka, Rakshit; Garg, Aarti

    2016-06-01

    Unlike some vertebrates and fishes, humans do not have the capacity for tooth regeneration after the loss of permanent teeth. Although artificial replacement with removable dentures, fixed prosthesis and implants is possible through advances in the field of prosthetic dentistry, it would be ideal to recreate a third set of natural teeth to replace lost dentition. For many years now, researchers in the field of tissue engineering have been trying to bioengineer dental tissues as well as whole teeth. In order to attain a whole tooth through dental engineering, that has the same or nearly same biological, mechanical and physical properties of a natural tooth, it's necessary to deal with all the cells and tissues which are concerned with the formation, maintenance and repair of the tooth. In this article we review the steps involved in odontogenesis or organogenesis of a tooth and progress in the bioengineering of a whole tooth.

  5. Immediate functional loading of single-tooth TiO2 grit-blasted implant restoration. A controlled prospective study in a porcine model. Part II: Histology and histomorphometry.

    NARCIS (Netherlands)

    Bousdras, V.A.; Walboomers, F.; Jansen, J.A.; Cunningham, J.L.; Blunn, G.; Petrie, A.; Jaecques, S.V.; Naert, I.E.; Sindet-Pedersen, S.; Goodship, A.E.

    2007-01-01

    BACKGROUND: Evidently, there is a fast-moving shift from delayed to immediate implant loading. The hypothesis to be tested was that bone reactions adjacent to single TiO2-microthreaded implants exposed to immediate masticatory loading for 10 weeks after placement would modulate osseointegration.

  6. Orthodontic applications of a superelastic shape-memory alloy model

    International Nuclear Information System (INIS)

    Glendenning, R.W.; Enlow, R.L.

    2000-01-01

    During orthodontic treatment, dental appliances (braces) made of shape memory alloys have the potential to provide nearly uniform low level stresses to dentitions during tooth movement over a large range of tooth displacement. In this paper we model superelastic behaviour of dental appliances using the finite element method and constitutive equations developed by F. Auricchio et al. Results of the mathematical model for 3-point bending and several promising 'closing loop' designs are compared with laboratory results for the same configurations. (orig.)

  7. Prevalence and patterns of permanent tooth agenesis in individuals with Down syndrome: a meta-analysis.

    Science.gov (United States)

    Palaska, Pinelopi K; Antonarakis, Gregory S

    2016-08-01

    The aims of the present study were to evaluate the prevalence and patterns of permanent tooth agenesis in individuals with Down syndrome, using meta-analysis methodology. Two independent investigators carried out a literature search to locate articles pertaining to permanent tooth agenesis in individuals with Down syndrome. The outcomes of interest were the prevalence and pattern of permanent tooth agenesis. Thirteen articles were selected for inclusion. The estimated overall prevalence of permanent tooth agenesis, excluding third molars, was 54.6% (95% CI: 44-66%). Considerable heterogeneity was present across the studies. Among subjects with tooth agenesis, approximately half had three or more missing teeth. The permanent teeth with the highest prevalence of agenesis were the maxillary lateral incisor (27%), mandibular second premolar (21%) and maxillary second premolar (18%). The single most commonly absent tooth, however, was the mandibular left second mandibular premolar (19.9%), followed by the maxillary left lateral incisor (19.4%). Little data describing specific tooth-agenesis patterns were available. In conclusion, individuals with Down syndrome display high prevalence rates and severity of agenesis of permanent teeth. Proper and timely diagnosis of missing permanent teeth is thus necessary, to allow a more comprehensive long-term treatment plan and a more favorable prognosis in these individuals. © 2016 Eur J Oral Sci.

  8. Three-dimensional mammalian tooth development using diceCT.

    Science.gov (United States)

    Nasrullah, Qamariya; Renfree, Marilyn B; Evans, Alistair R

    2018-01-01

    This study aims to develop the Diffusible Iodine-based Contrast-Enhanced CT (diceCT) method for non-destructive imaging of both soft and mineralised tissues. We sought to document the 3D spatio-temporal pattern of mammalian tooth development including multiple tooth classes and generations, using the tammar wallaby (Macropus eugenii) as a model species. We took microCT scans of developing fetuses and pouch young stained using Lugol's Iodine (I 2 KI) contrast agent. Stained versus unstained specimen comparisons were then made to investigate whether staining had improved visualisation of structures. Scan slices were compared to histological sections to confirm the identity of tissues and structures. Tissue layers were digitally segmented to create 3D models. DiceCT dramatically enhanced visual contrast of soft tissues, allowing differentiation between epithelial and mesenchymal layers. Subvolume scans at higher magnification achieved single-cell layer resolution within relatively large intact heads. We observed in-situ initiating teeth, which progressed through major stages of tooth development including morphogenesis and mineralisation. In addition, we traced the development of other mineralized and unmineralised tissues, such as the cranial bones and the brain, eye and olfactory system. DiceCT was time- and cost-effective in producing complex 3D models of the entire dentition of the tammar wallaby at each developmental stage with tissue-level resolution. The 3D view of soft and mineralised tooth structures allowed us to define tooth class and generation from a developmental perspective. Additionally, the development of other organs can also be documented using the same scans, demonstrating the efficiency and versatility of this technique. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Comparative evaluation of tooth substance loss and its correlation with the abrasivity and chemical composition of different dentifrices

    OpenAIRE

    Ram Prakash Singh; Sidhartha Sharma; Ajay Logani; Naseem Shah; Surendra Singh

    2016-01-01

    Context: In India, teeth cleaning with tooth powder is common in rural and semi-urban areas. These dentifrices may contain low-quality abrasives, which may have a deleterious effect on dental hard tissues. Aims: This study aims to evaluate the tooth substance loss caused by different dentifrices and to correlate it with chemical composition, size, and shape of abrasives used. Settings and Design: An indigenously made automated machine was used for brushing the specimens. Materials an...

  10. Analysis of tooth tissues using Raman spectroscopy

    International Nuclear Information System (INIS)

    Timchenko, E.V.; Timchenko, P.E.; Kulabukhova, A.Yu.; Volova, L.T.; Rosenbaum, A.Yu.

    2016-01-01

    The results of experimental studies of healthy tooth tissue and tooth tissues during caries disease are presented. Features of Raman spectrum of tooth tissues during caries disease are obtained: the main changes are detected at wavenumbers 956 cm -1 .1069 cm -1 . corresponding to phosphates. and 1241 cm -1 . 1660 cm -1 . corresponding to collagen III and collagen I. respectively. Were introduced criteria allowing to detect caries and to identify weakening of tooth tissues. preceding the caries. The reliability of research results is confirmed by scanning electron microscopy. (paper)

  11. Cracked tooth syndrome: Overview of literature

    OpenAIRE

    Hasan, Shamimul; Singh, Kuldeep; Salati, Naseer

    2015-01-01

    Pain is defined as an ?unpleasant sensory and emotional feeling which is associated with actual or potential injury of tissue or expressed in terms of such injury.? Tooth pain usually refers to pain around the teeth or jaws mainly as a result of a dental condition. Mostly, toothaches are caused by a carious cavity, a broken tooth, an exposed tooth root or gum disease. The toothache may sometimes be the result of radiating pain from structures in the vicinity of tooth and jaws (cardiac pain, e...

  12. Covering folded shapes

    Directory of Open Access Journals (Sweden)

    Oswin Aichholzer

    2014-05-01

    Full Text Available Can folding a piece of paper flat make it larger? We explore whether a shape S must be scaled to cover a flat-folded copy of itself. We consider both single folds and arbitrary folds (continuous piecewise isometries \\(S\\to\\mathbb{R}^2\\. The underlying problem is motivated by computational origami, and is related to other covering and fixturing problems, such as Lebesgue's universal cover problem and force closure grasps. In addition to considering special shapes (squares, equilateral triangles, polygons and disks, we give upper and lower bounds on scale factors for single folds of convex objects and arbitrary folds of simply connected objects.

  13. Charcot–Marie–Tooth disease

    Science.gov (United States)

    Szigeti, Kinga; Lupski, James R

    2009-01-01

    Charcot-Marie-Tooth (CMT) disease is a heterogeneous group of genetic disorders presenting with the phenotype of a chronic progressive neuropathy affecting both the motor and sensory nerves. During the last decade over two dozen genes have been identified in which mutations cause CMT. The disease illustrates a multitude of genetic principles, including diverse mutational mechanisms from point mutations to copy number variation (CNV), allelic heterogeneity, age-dependent penetrance and variable expressivity. Population based studies have determined the contributions of the various genes to disease burden enabling evidence-based approaches to genetic testing. PMID:19277060

  14. Tooth morphometry and the pattern of palatal rugae among monozygotic and dizygotic twins in India

    Directory of Open Access Journals (Sweden)

    Swagatika Panda

    2017-01-01

    Full Text Available Introduction: A stronger correlation of physical traits among monozygotic (MZ twins than dizygotic (DZ twins indicates predominant contribution by genetic factors than environmental factors. Exploring the degree of resemblance in tooth morphometry and the pattern of rugae among twins shall aid in forensic identification. Aim and Objective: To find out the degree of correlation in tooth morphometry and the palatal rugae pattern among MZ and DZ twins. Materials and Methods: The maximum coronal mesiodistal and buccolingual dimensions of the maxillary teeth excluding the second and third molars in 21 pairs of MZ and 12 pairs of DZ twins along with a MZ triplet were recorded using digital calipers calibrated to 0.01 mm. The dimensions of the teeth based on the number, shape, size, and the unification palatal rugae pattern among twin pairs were analyzed and recorded. Results: Our results suggest a stronger correlation of tooth dimension among MZ than DZ twins, which differs for individual maxillary tooth. There may be a separate set of genes responsible for controlling the mesiodistal and buccolingual tooth dimensions. The maxillary canine and maxillary premolars do show the least amount of genetic variability. The results in our study provide remarkable evidence regarding the existence of mirror imaging in tooth dimension as well as the number and shape of the palatal rugae. Conclusion: This first of its kind study in the Indian population suggests a remarkable similarity with regard to the tooth’s size and uniqueness of the palatal rugae pattern among MZ and DZ twins, which suggests their strong inheritability potential. This may be useful as additional tools for zygosity determination along with other dental traits. The significant evidence of mirror imaging of tooth dimension and rugae shall definitely contribute to the concept of development of human body.

  15. Schapiro Shapes

    Science.gov (United States)

    O'Connell, Emily

    2009-01-01

    This article describes a lesson on Schapiro Shapes. Schapiro Shapes is based on the art of Miriam Schapiro, who created a number of works of figures in action. Using the basic concepts of this project, students learn to create their own figures and styles. (Contains 1 online resource.)

  16. A simple rule governs the evolution and development of hominin tooth size.

    Science.gov (United States)

    Evans, Alistair R; Daly, E Susanne; Catlett, Kierstin K; Paul, Kathleen S; King, Stephen J; Skinner, Matthew M; Nesse, Hans P; Hublin, Jean-Jacques; Townsend, Grant C; Schwartz, Gary T; Jernvall, Jukka

    2016-02-25

    The variation in molar tooth size in humans and our closest relatives (hominins) has strongly influenced our view of human evolution. The reduction in overall size and disproportionate decrease in third molar size have been noted for over a century, and have been attributed to reduced selection for large dentitions owing to changes in diet or the acquisition of cooking. The systematic pattern of size variation along the tooth row has been described as a 'morphogenetic gradient' in mammal, and more specifically hominin, teeth since Butler and Dahlberg. However, the underlying controls of tooth size have not been well understood, with hypotheses ranging from morphogenetic fields to the clone theory. In this study we address the following question: are there rules that govern how hominin tooth size evolves? Here we propose that the inhibitory cascade, an activator-inhibitor mechanism that affects relative tooth size in mammals, produces the default pattern of tooth sizes for all lower primary postcanine teeth (deciduous premolars and permanent molars) in hominins. This configuration is also equivalent to a morphogenetic gradient, finally pointing to a mechanism that can generate this gradient. The pattern of tooth size remains constant with absolute size in australopiths (including Ardipithecus, Australopithecus and Paranthropus). However, in species of Homo, including modern humans, there is a tight link between tooth proportions and absolute size such that a single developmental parameter can explain both the relative and absolute sizes of primary postcanine teeth. On the basis of the relationship of inhibitory cascade patterning with size, we can use the size at one tooth position to predict the sizes of the remaining four primary postcanine teeth in the row for hominins. Our study provides a development-based expectation to examine the evolution of the unique proportions of human teeth.

  17. Regional odontodysplasia: A case of progressive tooth development

    Directory of Open Access Journals (Sweden)

    R Ganguly

    2012-01-01

    Full Text Available Regional odontodysplasia (RO is considered a relatively rare dental anomaly despite increasing numbers of case reports in recent years. It usually presents as a localized anomaly in tooth development affecting a few adjacent teeth in a single maxillary or mandibular quadrant. The purpose of this paper is to describe an uncommon case of regional odotodysplasia involving noncontiguous mandibular teeth, crossing the midline in a male patient, and showing progressive normalization of tooth anatomy over a period of 6 years. Typically, teeth affected with RO become pulpally involved early on and are either extracted or endodontically treated. Such reports of automatic normalization over time in RO is supportive of a more conservative treatment approach.

  18. Smile enhancement the conservative way: Tooth whitening procedures

    Science.gov (United States)

    Thosre, Deepika; Mulay, Sanjyot

    2009-01-01

    This article presents clinical cases in which different bleaching modalities have been used to successfully treat unsightly teeth. Depending upon the type and severity of discoloration, in-office vital and nonvital bleaching procedures were carried out. Discoloration of a single tooth has been managed using nonvital bleaching alone or with a combination of other minimally invasive modalities for an acceptable esthetic outcome. The case selection was done by considering the patient's needs and expectations, the type and cause of discoloration and patient economics. Moreover, prime importance was given to the conservation of the existing tooth structure and acquiring a complete change in the shade of teeth, which was comparable to that of the adjacent teeth. The desire to have a bright smile has become an important esthetic need of patients. The article explores various forms of bleaching and their successful usage in day-to-day clinical practice. PMID:20543927

  19. Graphene-based wireless bacteria detection on tooth enamel

    Science.gov (United States)

    Mannoor, Manu S.; Tao, Hu; Clayton, Jefferson D.; Sengupta, Amartya; Kaplan, David L.; Naik, Rajesh R.; Verma, Naveen; Omenetto, Fiorenzo G.; McAlpine, Michael C.

    2012-03-01

    Direct interfacing of nanosensors onto biomaterials could impact health quality monitoring and adaptive threat detection. Graphene is capable of highly sensitive analyte detection due to its nanoscale nature. Here we show that graphene can be printed onto water-soluble silk. This in turn permits intimate biotransfer of graphene nanosensors onto biomaterials, including tooth enamel. The result is a fully biointerfaced sensing platform, which can be tuned to detect target analytes. For example, via self-assembly of antimicrobial peptides onto graphene, we show bioselective detection of bacteria at single-cell levels. Incorporation of a resonant coil eliminates the need for onboard power and external connections. Combining these elements yields two-tiered interfacing of peptide-graphene nanosensors with biomaterials. In particular, we demonstrate integration onto a tooth for remote monitoring of respiration and bacteria detection in saliva. Overall, this strategy of interfacing graphene nanosensors with biomaterials represents a versatile approach for ubiquitous detection of biochemical targets.

  20. Structure and microstructure of Ni-Mn-Ga single crystal exhibiting magnetic shape memory effect analysed by high resolution X-ray diffraction

    Czech Academy of Sciences Publication Activity Database

    Heczko, Oleg; Cejpek, P.; Drahokoupil, Jan; Holý, V.

    2016-01-01

    Roč. 115, Aug (2016), s. 250-258 ISSN 1359-6454 R&D Projects: GA ČR GA13-30397S; GA ČR GA15-00262S Institutional support: RVO:68378271 Keywords : magnetic field-induced strain * magnetic shape memory effect * X-ray diffraction * structure of Ni-Mn-Ga Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 5.301, year: 2016

  1. Effect of repeated immersion solution cycles on the color stability of denture tooth acrylic resins

    Science.gov (United States)

    da SILVA, Paulo Maurício Batista; ACOSTA, Emílio José Tabaré Rodríguez; JACOBINA, Matheus; PINTO, Luciana de Rezende; PORTO, Vinícius Carvalho

    2011-01-01

    Objective Chemical solutions have been widely used for disinfection of dentures, but their effect on color stability of denture tooth acrylic resins after repeated procedures is still unclear. The aim of this in vitro study was to evaluate whether repeated cycles of chemical disinfectants affected the color stability of two denture tooth acrylic resins. Material and Methods Sixty disc-shaped specimens (40 mm x 3 mm) were fabricated from two different brands (Artiplus and Trilux) of denture tooth acrylic resin. The specimens from each brand (n=30) were randomly divided into 6 groups (n=5) and immersed in the following solutions: distilled water (control group) and 5 disinfecting solutions (1% sodium hypochlorite, 2% sodium hypochlorite, 5.25% sodium hypochlorite, 2% glutaraldehyde, and 4% chlorhexidine gluconate). Tooth color measurements were made by spectrophotometry. Before disinfection, the initial color of each tooth was recorded. Further color measurements were determined after subjecting the specimens to 7, 21, 30, 45, 60, and 90 immersion cycles in each tested solution. Color differences (ΔE*) were determined using the CIE L*a*b* color system. Data were analyzed using two-way repeated measures analysis of variance (ANOVA) followed by Tukey tests. The significance level was set at 5%. Results There were statistically significant differences in ΔE* among the 5 disinfectants and water during the 90 cycles of immersion for both denture tooth acrylic resins. Distilled water promoted the greatest color change in both denture tooth acrylic resins, nevertheless none of tested disinfectants promoted ΔE* values higher than 1.0 on these acrylic materials during the 90 cycles of disinfection. Conclusions Repeated immersion cycles in disinfecting solutions alter ∆E* values, however these values do not compromise the color of the tested denture tooth acrylic resins because they are imperceptible to the human eye. PMID:22230997

  2. Effect of repeated immersion solution cycles on the color stability of denture tooth acrylic resins

    Directory of Open Access Journals (Sweden)

    Paulo Maurício Batista da Silva

    2011-12-01

    Full Text Available OBJECTIVE: Chemical solutions have been widely used for disinfection of dentures, but their effect on color stability of denture tooth acrylic resins after repeated procedures is still unclear. The aim of this in vitro study was to evaluate whether repeated cycles of chemical disinfectants affected the color stability of two denture tooth acrylic resins. MATERIAL AND METHODS: Sixty disc-shaped specimens (40 mm x 3 mm were fabricated from two different brands (Artiplus and Trilux of denture tooth acrylic resin. The specimens from each brand (n=30 were randomly divided into 6 groups (n=5 and immersed in the following solutions: distilled water (control group and 5 disinfecting solutions (1% sodium hypochlorite, 2% sodium hypochlorite, 5.25% sodium hypochlorite, 2% glutaraldehyde, and 4% chlorhexidine gluconate. Tooth color measurements were made by spectrophotometry. Before disinfection, the initial color of each tooth was recorded. Further color measurements were determined after subjecting the specimens to 7, 21, 30, 45, 60, and 90 immersion cycles in each tested solution. Color differences (ΔE* were determined using the CIE L*a*b* color system. Data were analyzed using two-way repeated measures analysis of variance (ANOVA followed by Tukey tests. The significance level was set at 5%. RESULTS: There were statistically significant differences in ΔE* among the 5 disinfectants and water during the 90 cycles of immersion for both denture tooth acrylic resins. Distilled water promoted the greatest color change in both denture tooth acrylic resins, nevertheless none of tested disinfectants promoted ΔE* values higher than 1.0 on these acrylic materials during the 90 cycles of disinfection. CONCLUSIONS: Repeated immersion cycles in disinfecting solutions alter ΔE* values, however these values do not compromise the color of the tested denture tooth acrylic resins because they are imperceptible to the human eye.

  3. Effect of repeated immersion solution cycles on the color stability of denture tooth acrylic resins.

    Science.gov (United States)

    Silva, Paulo Maurício Batista da; Acosta, Emílio José Tabaré Rodríguez; Jacobina, Matheus; Pinto, Luciana de Rezende; Porto, Vinícius Carvalho

    2011-01-01

    Chemical solutions have been widely used for disinfection of dentures, but their effect on color stability of denture tooth acrylic resins after repeated procedures is still unclear. The aim of this in vitro study was to evaluate whether repeated cycles of chemical disinfectants affected the color stability of two denture tooth acrylic resins. Sixty disc-shaped specimens (40 mm x 3 mm) were fabricated from two different brands (Artiplus and Trilux) of denture tooth acrylic resin. The specimens from each brand (n=30) were randomly divided into 6 groups (n=5) and immersed in the following solutions: distilled water (control group) and 5 disinfecting solutions (1% sodium hypochlorite, 2% sodium hypochlorite, 5.25% sodium hypochlorite, 2% glutaraldehyde, and 4% chlorhexidine gluconate). Tooth color measurements were made by spectrophotometry. Before disinfection, the initial color of each tooth was recorded. Further color measurements were determined after subjecting the specimens to 7, 21, 30, 45, 60, and 90 immersion cycles in each tested solution. Color differences (ΔE*) were determined using the CIE L*a*b* color system. Data were analyzed using two-way repeated measures analysis of variance (ANOVA) followed by Tukey tests. The significance level was set at 5%. There were statistically significant differences in ΔE* among the 5 disinfectants and water during the 90 cycles of immersion for both denture tooth acrylic resins. Distilled water promoted the greatest color change in both denture tooth acrylic resins, nevertheless none of tested disinfectants promoted ΔE* values higher than 1.0 on these acrylic materials during the 90 cycles of disinfection. Repeated immersion cycles in disinfecting solutions alter ΔE* values, however these values do not compromise the color of the tested denture tooth acrylic resins because they are imperceptible to the human eye.

  4. Psychosocial Aspect of Anterior Tooth Discoloration among ...

    African Journals Online (AJOL)

    Sixty two (65.9%), 47 (50.0%) and 38 (40.4%) respectively reported that it prevented them from freely answering questions, smiling and interacting. After oral examination, 120 (31.2%) subjects had one form of anterior tooth discoloration. The cause of tooth discoloration in the majority 64 (16.7%) of the participants was due ...

  5. psychosocial aspect of anterior tooth discoloration among

    African Journals Online (AJOL)

    discoloration on the psychosocial well being of adolescents with a view to providing information that will aid the ... Keywords: Psychosocial, Anterior tooth discolouration, Adolescents. Ann Ibd. Pg. Med 2011. Vol.9, No.2 94-99 ... often results in loss of self-esteem and damage to physical and mental health.9,10 Tooth ...

  6. Life of a Tooth: A Visual Timeline

    Medline Plus

    Full Text Available ... Posture! Is My Child at Risk for Early Childhood Tooth Decay? Men: Looking for a Better Job? Start by Visiting the Dentist Learn what those dental words mean. The Life of a Tooth Home | InfoBites | Find a Dentist | Your Family's Oral Health | RSS About AGD | Contact AGD | Site Map | Reprints ...

  7. Orthodontic Tooth Movement: A Historic Prospective.

    Science.gov (United States)

    Will, Leslie A

    2016-01-01

    The earliest report on orthodontic tooth movement in the English literature was published in 1911. Oppenheim carried out studies on baboons to determine what histologic changes occurred during tooth movement. Reitan and many others carried out research into the nature of tooth movement. The pressure-tension model of tooth movement developed from these studies, whereby the two sides of the tooth responded to forces as if in isolation. A second theory, proposed by Stuteville in 1938, was the hydraulic theory of tooth movement. In this theory, fluid from the vasculature, lymphatic system and intercellular spaces responds to the forces of tooth movement, damping the force and limiting movement. Bien and Baumrind expanded on this theory with their own studies in the 1960s. It is clear that both the pressure-tension and fluid flow concepts have merit, but considerable work needs to be done to ascertain the details so that tooth movement can be managed and controlled. © 2016 S. Karger AG, Basel.

  8. Addressing Tooth Decay in Head Start Children

    Science.gov (United States)

    Knowlden, Adam P.; Hill, Lawrence F.; Alles-White, Monica L.; Cottrell, Randall R.

    2012-01-01

    Tooth decay is the most prevalent chronic disease of childhood. Oral health education and dental services are crucial to reducing the number of children afflicted with dental cavities. Due to limited access to preventative care, Head Start children are particularly vulnerable to tooth decay. This article outlines practical implications of a…

  9. Shape descriptors for mode-shape recognition and model updating

    International Nuclear Information System (INIS)

    Wang, W; Mottershead, J E; Mares, C

    2009-01-01

    The most widely used method for comparing mode shapes from finite elements and experimental measurements is the Modal Assurance Criterion (MAC), which returns a single numerical value and carries no explicit information on shape features. New techniques, based on image processing (IP) and pattern recognition (PR) are described in this paper. The Zernike moment descriptor (ZMD), Fourier descriptor (FD), and wavelet descriptor (WD), presented in this article, are the most popular shape descriptors having properties that include efficiency of expression, robustness to noise, invariance to geometric transformation and rotation, separation of local and global shape features and computational efficiency. The comparison of mode shapes is readily achieved by assembling the shape features of each mode shape into multi-dimensional shape feature vectors (SFVs) and determining the distances separating them.

  10. Mathematical description of tooth flank surface of globoidal worm gear with straight axial tooth profile

    Science.gov (United States)

    Połowniak, Piotr; Sobolak, Mariusz

    2017-12-01

    In this article, a mathematical description of tooth flank surface of the globoidal worm and worm wheel generated by the hourglass worm hob with straight tooth axial profile is presented. The kinematic system of globoidal worm gear is shown. The equation of globoid helix and tooth axial profile of worm is derived to determine worm tooth surface. Based on the equation of meshing the contact lines are obtained. The mathematical description of globoidal worm wheel tooth flank is performed on the basis of contact lines and generating the tooth side by the extreme cutting edge of worm hob. The presented mathematical model of tooth flank of TA worm and worm wheel can be used e.g. to analyse the contact pattern of the gear.

  11. Seeding Cracks Using a Fatigue Tester for Accelerated Gear Tooth Breaking

    Science.gov (United States)

    Nenadic, Nenad G.; Wodenscheck, Joseph A.; Thurston, Michael G.; Lewicki, David G.

    2011-01-01

    This report describes fatigue-induced seeded cracks in spur gears and compares them to cracks created using a more traditional seeding method, notching. Finite element analysis (FEA) compares the effective compliance of a cracked tooth to the effective compliance of a notched tooth where the crack and the notch are of the same depth. In this analysis, cracks are propagated to the desired depth using FRANC2D and effective compliances are computed in ANSYS. A compliance-based feature for detecting cracks on the fatigue tester is described. The initiated cracks are examined using both nondestructive and destructive methods. The destructive examination reveals variability in the shape of crack surfaces.

  12. Accelerated orthodontic tooth movement: molecular mechanisms.

    Science.gov (United States)

    Huang, Hechang; Williams, Ray C; Kyrkanides, Stephanos

    2014-11-01

    Accelerating orthodontic tooth movement can significantly reduce treatment duration and risks of side effects. The rate of orthodontic tooth movement is chiefly determined by the remodeling of tissues surrounding the roots; this in turn is under the control of molecular mechanisms regulating cellular behaviors in the alveolar bone and periodontal ligament. This review summarizes the current knowledge on the molecular mechanisms underlying accelerated orthodontic tooth movement, and the clinical and experimental methods that accelerate orthodontic tooth movement with possible molecular mechanisms. The review also shows directions for future studies to develop more clinically applicable methods to accelerate orthodontic tooth movement. Copyright © 2014 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  13. Comparative evaluation of tooth substance loss and its correlation with the abrasivity and chemical composition of different dentifrices.

    Science.gov (United States)

    Singh, Ram Prakash; Sharma, Sidhartha; Logani, Ajay; Shah, Naseem; Singh, Surendra

    2016-01-01

    In India, teeth cleaning with tooth powder is common in rural and semi-urban areas. These dentifrices may contain low-quality abrasives, which may have a deleterious effect on dental hard tissues. This study aims to evaluate the tooth substance loss caused by different dentifrices and to correlate it with chemical composition, size, and shape of abrasives used. An indigenously made automated machine was used for brushing the specimens. Sixty-four freshly extracted premolars were allocated to eight groups (n = 8). Colgate toothpaste was used as the control group. Each specimen was brushed in a vertical motion for 2½ h at 200 strokes/min with a constant applied load of 200 g corresponding to 6-month brushing. The difference in weight (pre- and post-brushing) was determined by an analytical weighing machine. Chemical analysis was done to determine the presence of iron oxide by Inductively Coupled Plasma Mass Spectrometry method. Shape and size of the abrasive particles was evaluated under scanning electron microscopy (SEM). One-way analysis of variance and Paired t-test were used to analyze the data. Tooth substance loss was maximum in the group brushed with red tooth powder, which was shown to contain the highest amount of iron oxide and also exhibited large, irregularly shaped abrasive particles under SEM. Tooth substance loss was documented to be correlated with chemical composition (iron oxide) and the size and shape of abrasive particles used in dentifrices.

  14. Direct observation of a-b twin laminate in monoclinic five-layered martensite of Ni-Mn-Ga magnetic shape memory single crystal

    Czech Academy of Sciences Publication Activity Database

    Heczko, Oleg; Klimša, Ladislav; Kopeček, Jaromír

    2017-01-01

    Roč. 131, Apr (2017), s. 76-79 ISSN 1359-6462 R&D Projects: GA MŠk LO1409; GA MŠk LM2015088; GA ČR GA15-00262S Grant - others:FUNBIO(XE) CZ.2.16/3.1.00/21568 Institutional support: RVO:68378271 Keywords : a-b twin laminate * magnetic shape memory alloys * martensitic transformation * twinning Subject RIV: BM - Solid Matter Physics ; Magnetism OBOR OECD: Condensed matter physics (including formerly solid state physics, supercond.) Impact factor: 3.747, year: 2016

  15. Analysis of split tooth as an unstudied reason for tooth extraction.

    Science.gov (United States)

    Osaghae, Ifueko Patience; Azodo, Clement Chinedu

    2014-09-10

    Split tooth is an unstudied reason for tooth extraction. The purpose of this study was to determine and analyze split tooth as a reason for extraction in a dental clinic in Benin City. The prospective study was carried out on 669 patients having tooth extraction between May, 2005 and December, 2012. Over the period of the study, diagnosis and tooth extraction were done by three dentists of more five years practice experience. The indications for tooth extraction were noted with specific interest on those diagnosed as split tooth without restoration. Data was entered into Microsoft excel, sorted and transported into SPSS (SPSS version 16.0, Chicago, IL, USA). Split teeth constituted for 39 (5%) of extracted teeth. This 39 extractions were done in 38 patients meaning that two split teeth were extracted on separate occasions from same patient. The majority 23 (61%) of extracted split tooth were done in patients in the fifth decade of life. More of the split tooth extraction were performed in males 28 (72%) than females 11 (28%). Overall mandibular teeth were more affected than the maxillary teeth and the most affected teeth were mandibular second molars 23 (59%) while the least affected were the mandibular first premolars 1 (3%) and the third molars 1 (3%). The reported masticatory accident as aetiology, were biting on stone 21 (53%) or piece of bone 10 (26%) while eating. A few 3 (8%) were suspected bruxists. The majority 25 (65%) visited the dental clinic 3-6 months after the incident and onset of symptoms. Split tooth constitute a reasonable common reason for tooth extraction and this was most common in the fifth decade of life. It is therefore important to improve early diagnosis of a cracked tooth in order to prevent the progression of the crack tooth to split tooth.

  16. Tooth whitening: what we now know.

    Science.gov (United States)

    Carey, Clifton M

    2014-06-01

    Current research about tooth whitening shows that it is safe and effective when manufacturer's protocol is followed, yet there are risks of which the profession and users should be aware. This update provides a summary of current research and assessment of the safety and efficacy of tooth whitening regimens. Tooth whitening has become one of the most frequently requested dental procedures by the public. The public has come to demand whiter, more perfect smiles and in response many choices for tooth whitening have been made available. These include home-based products such as toothpastes, gels, and films, as well as in-office based systems where products containing highly concentrated bleaching agents are applied under professional supervision. The profession and public have been aware of certain risks related to tooth whitening such as increased tooth sensitivity and gingival irritation. New research has shown that there are other risks such as tooth surface roughening and softening, increased potential for demineralization, degradation of dental restorations, and unacceptable color change of dental restorations. The new research is also focused on optimizing whitening procedures to reduce tooth sensitivity and to increase the persistence of the whitening. Current reports in the literature are reviewed that are related to the use of peroxide based whitening methods. These reports include in vitro studies for method optimization and mechanism as well as clinical studies on effects of various whitening regimens. When manufacturer's instructions are followed, hydrogen peroxide and carbamide peroxide based tooth whitening is safe and effective. Patients should be informed of the risks associated with tooth whitening and instructed on identification of adverse occurrences so that they may seek professional help as needed. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Mechanism of human tooth eruption

    DEFF Research Database (Denmark)

    Kjær, Inger

    2014-01-01

    Human eruption is a unique developmental process in the organism. The aetiology or the mechanism behind eruption has never been fully understood and the scientific literature in the field is extremely sparse. Human and animal tissues provide different possibilities for eruption analyses, briefly...... discussed in the introduction. Human studies, mainly clinical and radiological, have focused on normal eruption and gender differences. Why a tooth begins eruption and what enables it to move eruptively and later to end these eruptive movements is not known. Pathological eruption courses contribute......, and the ability of the periodontal ligament to adapt to eruptive movements. Animal studies and studies on normal and pathological eruption in humans can support and explain different aspects in the new theory. The eruption mechanism still needs elucidation and the paper recommends that future research on eruption...

  18. Tooth Decay Process: How to Reverse It and Avoid a Cavity

    Science.gov (United States)

    ... Finding Dental Care Home Health Info Health Topics Tooth Decay Tooth decay (dental caries) is damage to a tooth that can happen ... hole in a tooth, called a cavity. If tooth decay is not treated, it can cause pain, infection, ...

  19. Evaluation of autogenous tooth transplantation for replacement of the missing or unrestorable mandibular molar tooth

    Directory of Open Access Journals (Sweden)

    Wahiduj Jaman

    2017-06-01

    Full Text Available This study was undertaken to evaluate the functional and occlusal stability of autogenous tooth transplantation. A total of 30 patients were included. Among them, 21 participants received transplanted first molar and the remaining 9 received transplanted second molar. In all the cases, donor tooth were third molar. In each participant, extraction of un-restorable first or second molar tooth was performed which was then replaced by atrumatic extracted third molar tooth. Each third molar tooth was placed in the recipient extracted socket, followed by the evaluation of the occlusion and then stabilized with arch bar and ligature wire. Clinical follow-up evaluation was performed at 15 days, 3 and 12 months in respect to occlusal stability, tooth mobility and periodontal status. It was found that 23 transplanted tooth were successful and the remaining 7 tooth need long-term observation for the final outcome, which was statistically significant. It can be concluded that the autogenous tooth transplantation can replace missing tooth to ensure the preservation of function, aesthetic and to prevent bone resorption of the missing area of the jaw, which can lead to exceptional esthetic and functional outcome.

  20. Spectroscopic investigations of carious tooth decay.

    Science.gov (United States)

    Thareja, R K; Sharma, A K; Shukla, Shobha

    2008-11-01

    We report on the elemental composition of healthy and infected part of human tooth using laser induced breakdown spectroscopy (LIBS). We have used prominent constituent transitions in laser-excited tooth to diagnose the state of the tooth. A nanosecond laser pulse (355nm, 5ns) was used as an ablating pulse and the sodium (3s2S-3p2P) at 588.99 and (3s2S-3p2P) at 589.99nm, strontium (5s21S-1s5P) at 460.55nm, and calcium (3d3D-4f 3F0) at 452.55nm transitions for spectroscopic analysis. The spectroscopic observations in conjunction with discriminate analysis showed that calcium attached to the hydroxyapatite structure of the tooth was affected severely at the infected part of the tooth. The position-time plots generated from two-dimensional (2D) images conclusively showed a decrease in calcium concentration in the infected region of the irradiated tooth. Using the technique, we could distinguish between the healthy and carious parts of the tooth with significant accuracy.