WorldWideScience

Sample records for single tn5 insertion

  1. Insertions of transposon Tn5 into ribosomal protein PNA polymerase operons.

    Science.gov (United States)

    Hui, I; Maltman, K; Little, R; Hastrup, S; Johnsen, M; Fiil, N; Dennis, P

    1982-01-01

    The genetic organization and interrelationships between the two ribosomal protein transcription units (the L11 and L10 operons) from near 89 min on the Escherichia coli chromosome were studied by using insertional mutations generated by the kanamycin-resistant transposable element Tn5. The polar effects of Tn5 insertions on the expression of the L11, L1, L10, and L12 ribosomal protein genes and the beta RNA polymerase subunit gene were examined (i) by the level of beta-galactosidase activity generated from L10-lacZ and beta-lacZ gene fusions, (ii) by direct sodium dodecyl sulfate-polyacrylamide gel electrophoresis of the proteins specified by plasmid ribosomal protein genes in UV-irradiated maxicells, and (iii) by urea-polyacrylamide gel electrophoresis of plasmid- and chromosome-specified L12 protein. The results confirmed the organization of these genes into two transcription units as follows: PL11, rplK (L11), rplA (L1), PL10, rplJ (L10), rplL (L12), rpoB (beta). . .; they also localized the position of the PL10 promoter within an 80-nucleotide region near the end of the L1 gene. The results also support the idea that the translational regulatory proteins for the L11 and L10 operons are L1 and L10, respectively, and that the expression of the L12 gene is closely linked to L10 gene expression. Images PMID:6292159

  2. Chromosomal insertion of the entire Escherichia coli lactose operon, into two strains of Pseudomonas, using a modified mini-Tn5 delivery system

    DEFF Research Database (Denmark)

    Hansen, L. H.; Sørensen, S. J.; Jensen, Lars Bogø

    1997-01-01

    A 12-kb PstI fragment including the entire E. coli lactose operon (lacIPOZYA) was inserted in one copy into the chromosome of Pseudomonas putida, Pseudomonas fluorescens and an E. coli strain with lac(-) phenotype. This was made possible by improvements of an already existing mini-Tn5 transposon...... flanked by NotI sites needed in the mini-Tn5 delivery system; (b) the generation of E. coli nonlysogenic strains expressing the pi protein thus being capable of maintaining and delivering R6K-based mini-Tn5 vectors to other E. coli strains; (c) the successful insertion of the E. coli lactose operon...... into the P. fluorescens chromosome giving P. fluorescens the ability to grow on lactose; (d) evidence from Southern blotting that contradicts the assumption that the mini-Tn5 delivery system always creates one-copy inserts. These improvements allow insertion of large DNA fragments encoding highly expressed...

  3. A simple and novel method for RNA-seq library preparation of single cell cDNA analysis by hyperactive Tn5 transposase.

    Science.gov (United States)

    Brouilette, Scott; Kuersten, Scott; Mein, Charles; Bozek, Monika; Terry, Anna; Dias, Kerith-Rae; Bhaw-Rosun, Leena; Shintani, Yasunori; Coppen, Steven; Ikebe, Chiho; Sawhney, Vinit; Campbell, Niall; Kaneko, Masahiro; Tano, Nobuko; Ishida, Hidekazu; Suzuki, Ken; Yashiro, Kenta

    2012-10-01

    Deep sequencing of single cell-derived cDNAs offers novel insights into oncogenesis and embryogenesis. However, traditional library preparation for RNA-seq analysis requires multiple steps with consequent sample loss and stochastic variation at each step significantly affecting output. Thus, a simpler and better protocol is desirable. The recently developed hyperactive Tn5-mediated library preparation, which brings high quality libraries, is likely one of the solutions. Here, we tested the applicability of hyperactive Tn5-mediated library preparation to deep sequencing of single cell cDNA, optimized the protocol, and compared it with the conventional method based on sonication. This new technique does not require any expensive or special equipment, which secures wider availability. A library was constructed from only 100 ng of cDNA, which enables the saving of precious specimens. Only a few steps of robust enzymatic reaction resulted in saved time, enabling more specimens to be prepared at once, and with a more reproducible size distribution among the different specimens. The obtained RNA-seq results were comparable to the conventional method. Thus, this Tn5-mediated preparation is applicable for anyone who aims to carry out deep sequencing for single cell cDNAs. Copyright © 2012 Wiley Periodicals, Inc.

  4. Metabolite profiling reveals abiotic stress tolerance in Tn5 mutant of Pseudomonas putida.

    Directory of Open Access Journals (Sweden)

    Vasvi Chaudhry

    Full Text Available Pseudomonas is an efficient plant growth-promoting rhizobacteria (PGPR; however, intolerance to drought and high temperature limit its application in agriculture as a bioinoculant. Transposon 5 (Tn5 mutagenesis was used to generate a stress tolerant mutant from a PGPR Pseudomonas putida NBRI1108 isolated from chickpea rhizosphere. A mutant NBRI1108T, selected after screening of nearly 10,000 transconjugants, exhibited significant tolerance towards high temperature and drought. Southern hybridization analysis of EcoRI and XhoI restricted genomic DNA of NBRI1108T confirmed that it had a single Tn5 insertion. The metabolic changes in the polar and non-polar extracts of NBRI1108 and NBRI1108T were examined using 1H, 31P nuclear magnetic resonance (NMR spectroscopy and gas chromatography-mass spectrometry (GC-MS. Thirty six chemically diverse metabolites consisting of amino acids, fatty acids and phospholipids were identified and quantified. Insertion of Tn5 influenced amino acid and phospholipid metabolism and resulted in significantly higher concentration of aspartic acid, glutamic acid, glycinebetaine, glycerophosphatidylcholine (GPC and putrescine in NBRI1108T as compared to that in NBRI1108. The concentration of glutamic acid, glycinebetaine and GPC increased by 34%, 95% and 100%, respectively in the NBRI1108T as compared to that in NBRI1108. High concentration of glycerophosphatidylethanolamine (GPE and undetected GPC in NBRI1108 indicates that biosynthesis of GPE may have taken place via the methylation pathway of phospholipid biosynthesis. However, high GPC and low GPE concentration in NBRI1108T suggest that methylation pathway and phosphatidylcholine synthase (PCS pathway of phospholipid biosynthesis are being followed in the NBRI1108T. Application of multivariate principal component analysis (PCA on the quantified metabolites revealed clear variations in NBRI1108 and NBRI1108T in polar and non-polar metabolites. Identification of abiotic

  5. Transposon Tn5 encodes streptomycin resistance in nonenteric bacteria.

    OpenAIRE

    O'Neill, E A; Kiely, G M; Bender, R A

    1984-01-01

    Strains of Caulobacter crescentus, Pseudomonas putida, Acinetobacter calcoaceticus, Rhizobium meliloti, and Rhodopseudomonas sphaeroides carrying the kanamycin resistance-encoding transposon Tn5 were 15 to 500 times more resistant to streptomycin than transposon-free strains. The streptomycin resistance determinant, which is separable from the kanamycin resistance determinant of Tn5, was not expressed in Escherichia coli or Klebsiella aerogenes.

  6. Large-Scale Low-Cost NGS Library Preparation Using a Robust Tn5 Purification and Tagmentation Protocol

    Directory of Open Access Journals (Sweden)

    Bianca P. Hennig

    2018-01-01

    Full Text Available Efficient preparation of high-quality sequencing libraries that well represent the biological sample is a key step for using next-generation sequencing in research. Tn5 enables fast, robust, and highly efficient processing of limited input material while scaling to the parallel processing of hundreds of samples. Here, we present a robust Tn5 transposase purification strategy based on an N-terminal His6-Sumo3 tag. We demonstrate that libraries prepared with our in-house Tn5 are of the same quality as those processed with a commercially available kit (Nextera XT, while they dramatically reduce the cost of large-scale experiments. We introduce improved purification strategies for two versions of the Tn5 enzyme. The first version carries the previously reported point mutations E54K and L372P, and stably produces libraries of constant fragment size distribution, even if the Tn5-to-input molecule ratio varies. The second Tn5 construct carries an additional point mutation (R27S in the DNA-binding domain. This construct allows for adjustment of the fragment size distribution based on enzyme concentration during tagmentation, a feature that opens new opportunities for use of Tn5 in customized experimental designs. We demonstrate the versatility of our Tn5 enzymes in different experimental settings, including a novel single-cell polyadenylation site mapping protocol as well as ultralow input DNA sequencing.

  7. Host-dependent transposon Tn5-mediated streptomycin resistance.

    OpenAIRE

    De Vos, G F; Finan, T M; Signer, E R; Walker, G C

    1984-01-01

    Transposon Tn5 encodes streptomycin resistance in addition to kanamycin-neomycin resistance. This resistance was not detectable in Escherichia coli but was efficiently expressed in Rhizobium meliloti and certain other strains. By analysis of cloned Tn5 restriction endonuclease fragments, the streptomycin resistance (str) gene was located in the right-hand side of the central region as the transposon is conventionally drawn. Transcription of str appeared to originate at pL, the promoter for th...

  8. Genome-wide investigation of the genes involved in nicotine metabolism in Pseudomonas putida J5 by Tn5 transposon mutagenesis.

    Science.gov (United States)

    Xia, Zhenyuan; Zhang, Wei; Lei, Liping; Liu, Xingzhong; Wei, Hai-Lei

    2015-08-01

    Pseudomonas putida J5 is an efficient nicotine-degrading bacterial strain isolated from the tobacco rhizosphere. We successfully performed a comprehensive whole-genome analysis of nicotine metabolism-associated genes by Tn5 transposon mutagenesis in P. putida J5. A total of 18 mutants with unique insertions screened from 16,324 Tn5-transformants failed to use nicotine as the sole carbon source. Flanking sequences of the Tn5 transposon were cloned with a shotgun method from all of the nicotine-growth-deficient mutants. The potentially essential products of mutated gene were classified as follows: oxidoreductases, protein and metal transport systems, proteases and peptidases, transcriptional and translational regulators, and unknown proteins. Bioinformatic analysis of the Tn5 insertion sites indicated that the nicotine metabolic genes were separated and widely distributed in the genome. One of the mutants, M2022, was a Tn5 insert into a gene encoding a homolog of 6-hydroxy-L-nicotine oxidase, the second enzyme of nicotine metabolism in Arthrobacter nicotinovorans. Genetic and biochemical analysis confirmed that three open reading frames (ORFs) from an approximately 13-kb fragment recovered from the mutant M2022 were responsible for the transformation of nicotine to 3-succinoyl-pyridine via pseudooxynicotine and 3-succinoyl semialdehyde-pyridine, the first three steps of nicotine degradation. Further research on these mutants and the Tn5-inserted genes will help us characterize nicotine metabolic processes in P. putida J5.

  9. Tn5/7-lux: a versatile tool for the identification and capture of promoters in gram-negative bacteria.

    Science.gov (United States)

    Bruckbauer, Steven T; Kvitko, Brian H; Karkhoff-Schweizer, RoxAnn R; Schweizer, Herbert P

    2015-02-04

    The combination of imaging technologies and luciferase-based bioluminescent bacterial reporter strains provide a sensitive and simple non-invasive detection method (photonic bioimaging) for the study of diverse biological processes, as well as efficacy of therapeutic interventions, in live animal models of disease. The engineering of bioluminescent bacteria required for photonic bioimaging is frequently hampered by lack of promoters suitable for strong, yet stable luciferase gene expression. We devised a novel method for identification of constitutive native promoters in Gram-negative bacteria. The method is based on a Tn5/7 transposon that exploits the unique features of Tn5 (random transposition) and Tn7 (site-specific transposition). The transposons are designed such that Tn5 transposition will allow insertion of a promoter-less bacterial luxCDABE operon downstream of a bacterial gene promoter. Cloning of DNA fragments from luminescent isolates results in a plasmid that replicates in pir (+) hosts. Sequencing of the lux-chromosomal DNA junctions on the plasmid reveals transposon insertion sites within genes or operons. The plasmid is also a mini-Tn7-lux delivery vector that can be used to introduce the promoter-lux operon fusion into other derivatives of the bacterium of interest in an isogenic fashion. Alternatively, promoter-containing sequences can be PCR-amplified from plasmid or chromosomal DNA and cloned into a series of accompanying mini-Tn7-lux vectors. The mini-Tn5/7-lux and mini-Tn7-lux vectors are equipped with diverse selection markers and thus applicable in numerous Gram-negative bacteria. Various mini-Tn5/7-lux vectors were successfully tested for transposition and promoter identification by imaging in Acinetobacter baumannii, Escherichia coli, and Burkholderia pseudomallei. Strong promoters were captured for lux expression in E. coli and A. baumannii. Some mini-Tn7-lux vectors are also equipped with attB sites for swapping of the lux operon with

  10. Single-copy insertion of transgenes in Caenorhabditis elegans

    DEFF Research Database (Denmark)

    Frøkjaer-Jensen, Christian; Davis, M Wayne; Hopkins, Christopher E

    2008-01-01

    developed a method that inserts a single copy of a transgene into a defined site. Mobilization of a Mos1 transposon generates a double-strand break in noncoding DNA. The break is repaired by copying DNA from an extrachromosomal template into the chromosomal site. Homozygous single-copy insertions can...... be obtained in less than 2 weeks by injecting approximately 20 worms. We have successfully inserted transgenes as long as 9 kb and verified that single copies are inserted at the targeted site. Single-copy transgenes are expressed at endogenous levels and can be expressed in the female and male germlines....

  11. Single-copy insertion of transgenes in Caenorhabditis elegans.

    Science.gov (United States)

    Frøkjaer-Jensen, Christian; Davis, M Wayne; Hopkins, Christopher E; Newman, Blake J; Thummel, Jason M; Olesen, Søren-Peter; Grunnet, Morten; Jorgensen, Erik M

    2008-11-01

    At present, transgenes in Caenorhabditis elegans are generated by injecting DNA into the germline. The DNA assembles into a semistable extrachromosomal array composed of many copies of injected DNA. These transgenes are typically overexpressed in somatic cells and silenced in the germline. We have developed a method that inserts a single copy of a transgene into a defined site. Mobilization of a Mos1 transposon generates a double-strand break in noncoding DNA. The break is repaired by copying DNA from an extrachromosomal template into the chromosomal site. Homozygous single-copy insertions can be obtained in less than 2 weeks by injecting approximately 20 worms. We have successfully inserted transgenes as long as 9 kb and verified that single copies are inserted at the targeted site. Single-copy transgenes are expressed at endogenous levels and can be expressed in the female and male germlines.

  12. A clinical isolate of transposon Tn5 expressing streptomycin resistance in Escherichia coli.

    OpenAIRE

    Genilloud, O; Blázquez, J; Mazodier, P; Moreno, F

    1988-01-01

    The central region of transposon Tn5 carries three antibiotic resistance markers: neo, ble, and str. The str gene codes for a phosphotransferase that inactivates streptomycin. This activity is phenotypically expressed in several gram-negative bacteria but not in Escherichia coli. We identified a Tn5 variant in E. coli clinical isolates that express streptomycin resistance. This transposon carries a 6-base-pair deletion within the str gene, near the 3' end. The same kind of mutation had been p...

  13. Identification of Pathogenicity-Related Genes in Biofilm-Defective Acidovorax citrulli by Transposon Tn5 Mutagenesis

    Directory of Open Access Journals (Sweden)

    Jinyan Luo

    2015-11-01

    Full Text Available Biofilm formation is important for virulence of a large number of plant pathogenic bacteria. Indeed, some virulence genes have been found to be involved in the formation of biofilm in bacterial fruit blotch pathogen Acidovorax citrulli. However, some virulent strains of A. citrulli were unable to format biofilm, indicating the complexity between biofilm formation and virulence. In this study, virulence-related genes were identified in the biofilm-defective strain A1 of A. citrulli by using Tn5 insertion, pathogenicity test, and high-efficiency thermal asymmetric interlaced PCR (hiTAIL-PCR. Results from this study indicated that 22 out of the obtained 301 mutants significantly decreased the virulence of strain A1 compared to the wild-type. Furthermore, sequence analysis indicated that the obtained 22 mutants were due to the insertion of Tn5 into eight genes, including Aave 4244 (cation diffusion facilitator family transporter, Aave 4286 (hypothetical protein, Aave 4189 (alpha/beta hydrolase fold, Aave 1911 (IMP dehydrogenase/GMP reductase domain, Aave 4383 (bacterial export proteins, family 1, Aave 4256 (Hsp70 protein, Aave 0003 (histidine kinase, DNA gyrase B, and HSP90-like ATPase, and Aave 2428 (pyridoxal-phosphate dependent enzyme. Furthermore, the growth of mutant Aave 2428 was unaffected and even increased by the change in incubation temperature, NaCl concentration and the pH of the LB broth, indicating that this gene may be directly involved in the bacterial virulence. Overall, the determination of the eight pathogenicity-related genes in strain A1 will be helpful to elucidate the pathogenesis of biofilm-defective A. citrulli.

  14. Tn5-induced pBS286 plasmid mutations blocking early stages of napthalene oxidation

    International Nuclear Information System (INIS)

    Kosheleva, I.A.; Tsoi, T.V.; Ivashina, T.V.; Selifonov, S.A.; Starovoitov, I.I.; Boronin, A.M.

    1988-01-01

    The authors present data on the further analysis of the structural and functional organization of the nah region of plasmid pBS286 controlling the constitutive oxidation of naphthalene by Pseudomonas putida cells. They have studied Tn5-induced mutations blocking early stages of naphthalene oxidation. They present and discuss data providing evidence that, in contrast to plasmid NAH7, the mechanism of regulation of the nahl operon of plasmid NPL-1, the parent plasmid of plasmid pBS286, with inducible synthesis of naphthalene dioxygenase can include elements of a negative control with participation of the regulatory locus R, located proximal to the structural nah genes and closely linked to or overlapped by the inverted control DNA segment (4.2 kb). They also present data on the possibility of regulation of the activity of the catechol-splitting meta-pathway genes with the participation of products of early stages of naphthalene oxidation

  15. Identification and Characterization of Non-Cellulose-Producing Mutants of Gluconacetobacter hansenii Generated by Tn5 Transposon Mutagenesis

    Science.gov (United States)

    Deng, Ying; Nagachar, Nivedita; Xiao, Chaowen; Tien, Ming

    2013-01-01

    The acs operon of Gluconacetobacter is thought to encode AcsA, AcsB, AcsC, and AcsD proteins that constitute the cellulose synthase complex, required for the synthesis and secretion of crystalline cellulose microfibrils. A few other genes have been shown to be involved in this process, but their precise role is unclear. We report here the use of Tn5 transposon insertion mutagenesis to identify and characterize six non-cellulose-producing (Cel−) mutants of Gluconacetobacter hansenii ATCC 23769. The genes disrupted were acsA, acsC, ccpAx (encoding cellulose-complementing protein [the subscript “Ax” indicates genes from organisms formerly classified as Acetobacter xylinum]), dgc1 (encoding guanylate dicyclase), and crp-fnr (encoding a cyclic AMP receptor protein/fumarate nitrate reductase transcriptional regulator). Protein blot analysis revealed that (i) AcsB and AcsC were absent in the acsA mutant, (ii) the levels of AcsB and AcsC were significantly reduced in the ccpAx mutant, and (iii) the level of AcsD was not affected in any of the Cel− mutants. Promoter analysis showed that the acs operon does not include acsD, unlike the organization of the acs operon of several strains of closely related Gluconacetobacter xylinus. Complementation experiments confirmed that the gene disrupted in each Cel− mutant was responsible for the phenotype. Quantitative real-time PCR and protein blotting results suggest that the transcription of bglAx (encoding β-glucosidase and located immediately downstream from acsD) was strongly dependent on Crp/Fnr. A bglAx knockout mutant, generated via homologous recombination, produced only ∼16% of the wild-type cellulose level. Since the crp-fnr mutant did not produce any cellulose, Crp/Fnr may regulate the expression of other gene(s) involved in cellulose biosynthesis. PMID:24013627

  16. A method for the analysis of 32 X chromosome insertion deletion polymorphisms in a single PCR

    DEFF Research Database (Denmark)

    Pereira, Rui; Pereira, Vania; Gomes, Iva

    2012-01-01

    Studies of human genetic variation predominantly use short tandem repeats (STRs) and single nucleotide polymorphisms (SNPs) but Insertion deletion polymorphisms (Indels) are being increasingly explored. They combine desirable characteristics of other genetic markers, especially the possibility...

  17. Completion of the nucleotide sequence of the central region of Tn5 confirms the presence of three resistance genes.

    OpenAIRE

    Mazodier, P; Cossart, P; Giraud, E; Gasser, F

    1985-01-01

    The DNA sequence of the region located downstream from the kanamycin resistance gene of Tn5 up to the right inverted repeat IS50R has been determined. This completes the determination of the sequence of Tn5 which is 5818 bp long. The 2.7 Kb central region contains three resistance genes: the kanamycin-neomycin resistance gene, a gene coding for resistance to CL990 an antimitotic-antibiotic compound of the bleomycin family and a third gene that confers streptomycin resistance in some bacterial...

  18. Assessing Tn5 and Sleeping Beauty for transpositional transgenesis by cytoplasmic injection into bovine and ovine zygotes

    Science.gov (United States)

    Bevacqua, R. J.; Fernandez-Martin, R.; Canel, N. G.; Gibbons, A.; Texeira, D.; Lange, F.; Vans Landschoot, G.; Savy, V.; Briski, O.; Hiriart, M. I.; Grueso, E.; Ivics, Z.; Taboga, O.; Kues, W. A.; Ferraris, S.

    2017-01-01

    Transgenic domestic animals represent an alternative to bioreactors for large-scale production of biopharmaceuticals and could also provide more accurate biomedical models than rodents. However, their generation remains inefficient. Recently, DNA transposons allowed improved transgenesis efficiencies in mice and pigs. In this work, Tn5 and Sleeping Beauty (SB) transposon systems were evaluated for transgenesis by simple cytoplasmic injection in livestock zygotes. In the case of Tn5, the transposome complex of transposon nucleic acid and Tn5 protein was injected. In the case of SB, the supercoiled plasmids encoding a transposon and the SB transposase were co-injected. In vitro produced bovine zygotes were used to establish the cytoplasmic injection conditions. The in vitro cultured blastocysts were evaluated for reporter gene expression and genotyped. Subsequently, both transposon systems were injected in seasonally available ovine zygotes, employing transposons carrying the recombinant human factor IX driven by the beta-lactoglobulin promoter. The Tn5 approach did not result in transgenic lambs. In contrast, the Sleeping Beauty injection resulted in 2 lambs (29%) carrying the transgene. Both animals exhibited cellular mosaicism of the transgene. The extraembryonic tissues (placenta or umbilical cord) of three additional animals were also transgenic. These results show that transpositional transgenesis by cytoplasmic injection of SB transposon components can be applied for the production of transgenic lambs of pharmaceutical interest. PMID:28301581

  19. Single phase and two-phase flow pressure losses through restrictions, expansions and inserts

    International Nuclear Information System (INIS)

    Glenat, P.; Solignac, P.

    1984-11-01

    We give a selection of methods to predict pressure losses through retrictions, expansions and inserts. In single phase flow, we give the classical method based on the one-dimensional momentum and mass balances. In two-phase flow, we propose the method given by Harshe et al. and an empirical approach suggested by Chisholm. We notice the distinction between long and short inserts depends upon wether or not the vena contracta lies within insert. Finally, we propose three correlations to calculate void fraction through the singularities which have been considered [fr

  20. The BDGP gene disruption project: Single transposon insertions associated with 40 percent of Drosophila genes

    Energy Technology Data Exchange (ETDEWEB)

    Bellen, Hugo J.; Levis, Robert W.; Liao, Guochun; He, Yuchun; Carlson, Joseph W.; Tsang, Garson; Evans-Holm, Martha; Hiesinger, P. Robin; Schulze, Karen L.; Rubin, Gerald M.; Hoskins, Roger A.; Spradling, Allan C.

    2004-01-13

    The Berkeley Drosophila Genome Project (BDGP) strives to disrupt each Drosophila gene by the insertion of a single transposable element. As part of this effort, transposons in more than 30,000 fly strains were localized and analyzed relative to predicted Drosophila gene structures. Approximately 6,300 lines that maximize genomic coverage were selected to be sent to the Bloomington Stock Center for public distribution, bringing the size of the BDGP gene disruption collection to 7,140 lines. It now includes individual lines predicted to disrupt 5,362 of the 13,666 currently annotated Drosophila genes (39 percent). Other lines contain an insertion at least 2 kb from others in the collection and likely mutate additional incompletely annotated or uncharacterized genes and chromosomal regulatory elements. The remaining strains contain insertions likely to disrupt alternative gene promoters or to allow gene mis-expression. The expanded BDGP gene disruption collection provides a public resource that will facilitate the application of Drosophila genetics to diverse biological problems. Finally, the project reveals new insight into how transposons interact with a eukaryotic genome and helps define optimal strategies for using insertional mutagenesis as a genomic tool.

  1. Testing of the large bore single aperture 1-meter superconducting dipoles made with phenolic inserts

    CERN Document Server

    Boschmann, H; Dubbeldam, R L; Kirby, G A; Lucas, J; Ostojic, R; Russenschuck, Stephan; Siemko, A; Taylor, T M; Vanenkov, I; Weterings, W

    1998-01-01

    Two identical single aperture 1-metre superconducting dipoles have been built in collaboration with HMA Power Systems and tested at CERN. The 87.8 mm aperture magnets feature a single layer coil wound using LHC main dipole outer layer cable, phenolic spacer type collars, and a keyed two part structural iron yoke. The magnets are designed as models of the D1 separation dipole in the LHC experimental insertions, whose nominal field is 4.5 T at 4.5 K. In this report we present the test results of the two magnets at 4.3 K and 1.9 K.

  2. Targeted genetics in Drosophila cell lines: Inserting single transgenes in vitro.

    Science.gov (United States)

    Manivannan, Sathiya N; Simcox, Amanda

    2016-07-02

    A long-standing problem with analyzing transgene expression in tissue-culture cells is the variation caused by random integration of different copy numbers of transfected transgenes. In mammalian cells, single transgenes can be inserted by homologous recombination but this process is inefficient in Drosophila cells. To tackle this problem, our group, and the Cherbas group, used recombination-mediated cassette exchange (RMCE) to introduce single-copy transgenes into specific locations in the Drosophila genome. In both cases, ϕC31 was used to catalyze recombination between its target sequences attP in the genome, and attB flanking the donor sequence. We generated cell lines de novo with a single attP-flanked cassette for recombination, whereas, Cherbas et al. introduced a single attP-flanked cassette into existing cell lines. In both approaches, a 2-drug selection scheme was used to select for cells with a single copy of the donor sequence inserted by RMCE and against cells with random integration of multiple copies. Here we describe the general advantages of using RMCE to introduce genes into fly cells, the different attributes of the 2 methods, and how future work could make use of other recombinases and CRISPR/Cas9 genome editing to further enable genetic manipulation of Drosophila cells in vitro.

  3. Fabrication of nanopores with ultrashort single-walled carbon nanotubes inserted in a lipid bilayer.

    Science.gov (United States)

    Liu, Lei; Xie, Jiani; Li, Ting; Wu, Hai-Chen

    2015-11-01

    We describe a protocol for the insertion of ultrashort single-walled carbon nanotubes (SWCNTs) to form nanopores in a Montal-Mueller lipid bilayer. The SWCNTs are designed to bind to a specific analyte of interest; binding will result in the reduction of current in single-channel recording experiments. The first stage of the PROCEDURE is to cut and separate the SWCNTs. We cut long, purified SWCNTs with sonication in concentrated sulfuric acid/nitric acid (3/1). Isolation of ultrashort SWCNTs is carried out by size-exclusion HPLC separation. The second stage is to insert these short SWCNTs into the lipid bilayer. This step requires a microinjection probe made from a glass capillary. The setup for protein nanopore research can be adopted for the single-channel recording experiments without any special treatment. The obtained current traces are of very high quality, showing stable baselines and little background noise. Example procedures are shown for investigating ion transport and DNA translocation through these SWCNT nanopores. This nanopore has potential applications in molecular sensing, nanopore DNA sequencing and early disease diagnosis. For example, we have selectively detected modified 5-hydroxymethylcytosine in single-stranded DNA (ssDNA), which may have implications in screening specific genomic DNA sequences. The protocol takes ∼15 d, including SWCNT purification, cutting and separation, as well as the formation of SWCNT nanopores for DNA analyses.

  4. Single photon image from PET with insertable collimator for boron neutron capture therapy

    International Nuclear Information System (INIS)

    Jung, Jooyoung; Suh, Tae Suk; Hong, Key Jo

    2014-01-01

    Boron neutron capture therapy (BNCT) is a radiation therapy technique for treating deep-seated brain tumors by irradiation with a thermal neutron in which boron-labelled low molecular weight compounds. Once completed, a single photon emission computed tomography (SPECT) scan is conducted to investigate for the region of therapy using an isotope exclusive to SPECT. In the case of an existing PET/SPECT combination system, at least two types of isotopes should be used for each scan with their purposes. Recently, researchers examined the effects of PET/SPECT dual modality on animal imaging systems. They reported that the PET/SPECT combination system was effective for simultaneous achievement of a single event and coincidence. The aim of our proposed system is to confirm the feasibility of extraction of two types of images from one PET module with an insertable collimator for brain tumor treatment during the BNCT. We attempted to acquire the PET and SPECT images simultaneously using only PET without an additional isotope. Single photon images were acquired using an insertable collimator on a PET detector

  5. Two hundred seventy-five single-incision laparoscopic gastric band insertions: what have we learnt?

    Science.gov (United States)

    Murgatroyd, Beth; Chakravartty, Saurav; Sarma, Diwakar R; Patel, Ameet G

    2014-07-01

    Single-incision surgery in the morbidly obese patient has not been widely adopted, but remains a popular choice amongst patients. In the bariatric patient, it presents its own surgical challenges with hepatomegaly and increased abdominal adiposity. Here, we present our experience of 275 single-incision laparoscopic gastric bands.Between June 2009 and April 2013, 275 obese patients underwent single-incision laparoscopic adjustable gastric banding through a single incision using a multichannel single port and via a pars flaccida approach. Prospective data collection was undertaken including operating time, additional ports and additional procedures undertaken.In this series, median operative time was 60 (range 34-170) min. An additional port was placed in 15 patients (5%), including two conversions to four-port technique (0.7%). Of these patients (n = 15), the majority were male (p rate of success for all BMIs. Following 275 single-incision band insertions additional port placements were more commonly required in male patients, BMI >45 and earlier in the learning curve.

  6. Irradiation-induced Deinococcus radiodurans genome fragmentation triggers transposition of a single resident insertion sequence.

    Directory of Open Access Journals (Sweden)

    Cécile Pasternak

    2010-01-01

    Full Text Available Stress-induced transposition is an attractive notion since it is potentially important in creating diversity to facilitate adaptation of the host to severe environmental conditions. One common major stress is radiation-induced DNA damage. Deinococcus radiodurans has an exceptional ability to withstand the lethal effects of DNA-damaging agents (ionizing radiation, UV light, and desiccation. High radiation levels result in genome fragmentation and reassembly in a process which generates significant amounts of single-stranded DNA. This capacity of D. radiodurans to withstand irradiation raises important questions concerning its response to radiation-induced mutagenic lesions. A recent study analyzed the mutational profile in the thyA gene following irradiation. The majority of thyA mutants resulted from transposition of one particular Insertion Sequence (IS, ISDra2, of the many different ISs in the D. radiodurans genome. ISDra2 is a member of a newly recognised class of ISs, the IS200/IS605 family of insertion sequences.

  7. Low-frequency excitations of C60 chains inserted inside single-walled carbon nanotubes

    International Nuclear Information System (INIS)

    Cambedouzou, J.; Rols, S.; Almairac, R.; Sauvajol, J.-L.; Kataura, H.; Schober, H.

    2005-01-01

    The low-frequency excitations of C 60 chains inserted inside single-walled carbon nanotubes (SWNTs) have been studied by inelastic neutron scattering on a high-quality sample of peapods. The comparison of the neutron-derived generalized phonon density of states (GDOS) of the peapods sample with that of raw SWNTs allows the vibrational properties of the C 60 chains encapsulated in the hollow core of the SWNTs to be probed. Lattice dynamical models are used to calculate the GDOS of chains of monomers, dimers, and polymers inserted into SWNTs, which are compared to the experimental data. The presence of strong interactions between C 60 cages inside the nanotube is clearly demonstrated by an excess of mode density in the frequency range around 10 meV. However, the presence of a quasielastic signal indicates that some of the C 60 's undergo rotational motion. This suggests that peapods are made from a mixture of C 60 monomers and C 60 n-mer (dimer, trimer, ..., polymer) structures

  8. The minimal replicon of the Streptomyces ghanaensis plasmid pSG5 identified by subcloning and Tn5 mutagenesis.

    Science.gov (United States)

    Muth, G; Wohlleben, W; Pühler, A

    1988-03-01

    The cryptic plasmid pSG5 of Streptomyces ghanaensis 5/1B (DSM 2932) was characterized to have a molecular size of 12.7 kb and approximate copy number of 20-50 per chromosome. A bifunctional derivative, designated pSW344E, consisting of pSG5 and an Escherichia coli vector plasmid was constructed. Following Tn5 mutagenesis in E. coli, the replication functions of the mutagenized pSW344E plasmids were analysed in S.lividans. A 2 kb DNA fragment of the pSG5 replicon was found to carry replication functions. Subcloning of pSG5 DNA into various replication probe vectors resulted in the identification of the pSG5 minimal replicon, identical to the above mentioned 2 kb DNA region. Several small bifunctional plasmids, able to replicate in E. coli as well as in Streptomyces, were generated during subcloning. Some of these plasmids were found to be useful shuttle vectors.

  9. A single-stage polymerase-based protocol for the introduction of deletions and insertions without subcloning.

    Science.gov (United States)

    Salerno, John C; Jones, Rachel J; Erdogan, Eda; Smith, Susan M E

    2005-03-01

    A single-stage polymerase-based procedure is described that allows extensive modifications of DNA. The version described here uses the QuikChange Site-Directed Mutagenesis System kit supplied by Stratagene. The original protocol is replaced by a single-stage method in which linear production of complementary strands is accomplished in separate single primer reactions. This has proved effective in introducing insertions and deletions into large gene/vector combinations without subcloning.

  10. Soft Tissue Stability around Single Implants Inserted to Replace Maxillary Lateral Incisors: A 3D Evaluation

    Directory of Open Access Journals (Sweden)

    F. G. Mangano

    2016-01-01

    Full Text Available Purpose. To evaluate the soft tissue stability around single implants inserted to replace maxillary lateral incisors, using an innovative 3D method. Methods. We have used reverse-engineering software for the superimposition of 3D surface models of the dentogingival structures, obtained from intraoral scans of the same patients taken at the delivery of the final crown (S1 and 2 years later (S2. The assessment of soft tissues changes was performed via calculation of the Euclidean surface distances between the 3D models, after the superimposition of S2 on S1; colour maps were used for quantification of changes. Results. Twenty patients (8 males, 12 females were selected, 10 with a failing/nonrestorable lateral incisor (test group: immediate placement in postextraction socket and 10 with a missing lateral incisor (control group: conventional placement in healed ridge. Each patient received one immediately loaded implant (Anyridge®, Megagen, Gyeongbuk, South Korea. The superimposition of the 3D surface models taken at different times (S2 over S1 revealed a mean (±SD reduction of 0.057 mm (±0.025 and 0.037 mm (±0.020 for test and control patients, respectively. This difference was not statistically significant (p = 0.069. Conclusions. The superimposition of the 3D surface models revealed an excellent peri-implant soft tissue stability in both groups of patients, with minimal changes registered along time.

  11. Identifying and calling insertions, deletions, and single-base mutations efficiently from sequence data

    Science.gov (United States)

    Whole genome sequencing studies can directly identify causative mutations for subsequent use in genomic evaluations, but sequence variant identification is a lengthy and sometimes inaccurate process. The speed and accuracy of identifying small insertions and deletions of sequence, collectively terme...

  12. Tryptophan auxotrophs were obtained by random transposon insertions in the Methanococcus maripaludis tryptophan operon.

    Science.gov (United States)

    Porat, Iris; Whitman, William B

    2009-08-01

    Methanococcus maripaludis is an anaerobic, methane-producing archaeon that utilizes H(2) or formate for the reduction of CO(2) to methane. Tryptophan auxotrophs were constructed by in vitro insertions of the Tn5 transposon into the tryptophan operon, followed by transformation into M. maripaludis. This method could serve for rapid insertions into large cloned DNA regions.

  13. Insertion of linear 8.4 μm diameter 16 channel carbon fiber electrode arrays for single unit recordings

    Science.gov (United States)

    Patel, Paras R.; Na, Kyounghwan; Zhang, Huanan; Kozai, Takashi D. Y.; Kotov, Nicholas A.; Yoon, Euisik; Chestek, Cynthia A.

    2016-01-01

    Objective Single carbon fiber electrodes (d=8.4 μm) insulated with parylene-c and functionalized with PEDOT:pTS have been shown to record single unit activity but manual implantation of these devices with forceps can be difficult. Without an improvement in the insertion method any increase in the channel count by fabricating carbon fiber arrays would be impractical. In this study, we utilize a water soluble coating and structural backbones that allow us to create, implant, and record from fully functionalized arrays of carbon fibers with ~150 μm pitch. Approach Two approaches were tested for the insertion of carbon fiber arrays. The first method used a PEG coating that temporarily stiffened the fibers while leaving a small portion at the tip exposed. The small exposed portion (500 μm – 1 mm) readily penetrated the brain allowing for an insertion that did not require the handling of each fiber by forceps. The second method involved the fabrication of silicon support structures with individual shanks spaced 150 μm apart. Each shank consisted of a small groove that held an individual carbon fiber. Main results Our results showed that the PEG coating allowed for the chronic implantation of carbon fiber arrays in 5 rats with unit activity detected at 31 days post-implant. The silicon support structures recorded single unit activity in 3 acute rat surgeries. In one of those surgeries a stacked device with 3 layers of silicon support structures and carbon fibers was built and shown to readily insert into the brain with unit activity on select sites. Significance From these studies we have found that carbon fibers spaced at ~150 μm readily insert into the brain. This greatly increases the recording density of chronic neural probes and paves the way for even higher density devices that have a minimal scarring response. PMID:26035638

  14. Image-guided chemoport insertion by interventional radiologists: A single-center experience on periprocedural complications

    International Nuclear Information System (INIS)

    Yaacob, Yazmin; Nguyen, Dang V; Mohamed, Zahiah; Ralib, A Razali A; Zakaria, Rozman; Muda, Sobri

    2013-01-01

    To report our early experience in image-guided chemoport insertions by interventional radiologists. This was a cross-sectional study conducted in a tertiary center with 161 chemoport insertions done from June 2008 to June 2010. The chemoports were inserted either at the angiography suite or at the mobile operation theater unit. Ninety percent of the chemoports had right internal jugular vein (IJV) as the entry site. Other entry sites included the left IJV, subclavian veins and the inferior vena cava. Immediate and early complications were recorded. All insertions were performed under image guidance with the aid of ultrasound and fluoroscopy. The technical success rate was 99.4%. In terms of immediate complications, there were only two cases of arterial puncture that resolved with local compression. No pneumothorax or air embolism was documented. Twenty-six early complications were recorded. The most common early complication was catheter blockage (12/161; 7.4%), followed by catheter-related infection (9/161; 5.6%). Other complications were catheter malposition, venous thrombosis and catheter dislodgement or leak. A total of 11 (6.8%) chemoports had to be removed within 30 days; most of them were due to infections that failed to respond to systemic antibiotic therapy. In terms of place of procedure, there were no significant differences in complication rates between the angiography suite and the mobile operation theater unit. Image-guided chemoport insertion by interventional radiologist gives low periprocedural complication rates. Using right IJV as the entry site, the image guidance gives good success rate with least complication

  15. Image-guided chemoport insertion by interventional radiologists: A single-center experience on periprocedural complications.

    Science.gov (United States)

    Yaacob, Yazmin; Nguyen, Dang V; Mohamed, Zahiah; Ralib, A Razali A; Zakaria, Rozman; Muda, Sobri

    2013-04-01

    To report our early experience in image-guided chemoport insertions by interventional radiologists. This was a cross-sectional study conducted in a tertiary center with 161 chemoport insertions done from June 2008 to June 2010. The chemoports were inserted either at the angiography suite or at the mobile operation theater unit. Ninety percent of the chemoports had right internal jugular vein (IJV) as the entry site. Other entry sites included the left IJV, subclavian veins and the inferior vena cava. Immediate and early complications were recorded. All insertions were performed under image guidance with the aid of ultrasound and fluoroscopy. The technical success rate was 99.4%. In terms of immediate complications, there were only two cases of arterial puncture that resolved with local compression. No pneumothorax or air embolism was documented. Twenty-six early complications were recorded. The most common early complication was catheter blockage (12/161; 7.4%), followed by catheter-related infection (9/161; 5.6%). Other complications were catheter malposition, venous thrombosis and catheter dislodgement or leak. A total of 11 (6.8%) chemoports had to be removed within 30 days; most of them were due to infections that failed to respond to systemic antibiotic therapy. In terms of place of procedure, there were no significant differences in complication rates between the angiography suite and the mobile operation theater unit. Image-guided chemoport insertion by interventional radiologist gives low periprocedural complication rates. Using right IJV as the entry site, the image guidance gives good success rate with least complication.

  16. Image-guided chemoport insertion by interventional radiologists: A single-center experience on periprocedural complications

    Directory of Open Access Journals (Sweden)

    Yazmin Yaacob

    2013-01-01

    Full Text Available Purpose: To report our early experience in image-guided chemoport insertions by interventional radiologists. Materials and Methods: This was a cross-sectional study conducted in a tertiary center with 161 chemoport insertions done from June 2008 to June 2010. The chemoports were inserted either at the angiography suite or at the mobile operation theater unit. Ninety percent of the chemoports had right internal jugular vein (IJV as the entry site. Other entry sites included the left IJV, subclavian veins and the inferior vena cava. Immediate and early complications were recorded. All insertions were performed under image guidance with the aid of ultrasound and fluoroscopy. Results: The technical success rate was 99.4%. In terms of immediate complications, there were only two cases of arterial puncture that resolved with local compression. No pneumothorax or air embolism was documented. Twenty-six early complications were recorded. The most common early complication was catheter blockage (12/161; 7.4%, followed by catheter-related infection (9/161; 5.6%. Other complications were catheter malposition, venous thrombosis and catheter dislodgement or leak. A total of 11 (6.8% chemoports had to be removed within 30 days; most of them were due to infections that failed to respond to systemic antibiotic therapy. In terms of place of procedure, there were no significant differences in complication rates between the angiography suite and the mobile operation theater unit. Conclusion: Image-guided chemoport insertion by interventional radiologist gives low periprocedural complication rates. Using right IJV as the entry site, the image guidance gives good success rate with least complication.

  17. A novel adaptive needle insertion sequencing for robotic, single needle MR-guided high-dose-rate prostate brachytherapy

    Science.gov (United States)

    Borot de Battisti, M.; de Senneville, B. Denis; Hautvast, G.; Binnekamp, D.; Lagendijk, J. J. W.; Maenhout, M.; Moerland, M. A.

    2017-05-01

    MR-guided high-dose-rate (HDR) brachytherapy has gained increasing interest as a treatment for patients with localized prostate cancer because of the superior value of MRI for tumor and surrounding tissues localization. To enable needle insertion into the prostate with the patient in the MR bore, a single needle MR-compatible robotic system involving needle-by-needle dose delivery has been developed at our institution. Throughout the intervention, dose delivery may be impaired by: (1) sub-optimal needle positioning caused by e.g. needle bending, (2) intra-operative internal organ motion such as prostate rotations or swelling, or intra-procedural rectum or bladder filling. This may result in failure to reach clinical constraints. To assess the first aforementioned challenge, a recent study from our research group demonstrated that the deposited dose may be greatly improved by real-time adaptive planning with feedback on the actual needle positioning. However, the needle insertion sequence is left to the doctor and therefore, this may result in sub-optimal dose delivery. In this manuscript, a new method is proposed to determine and update automatically the needle insertion sequence. This strategy is based on the determination of the most sensitive needle track. The sensitivity of a needle track is defined as its impact on the dose distribution in case of sub-optimal positioning. A stochastic criterion is thus presented to determine each needle track sensitivity based on needle insertion simulations. To assess the proposed sequencing strategy, HDR prostate brachytherapy was simulated on 11 patients with varying number of needle insertions. Sub-optimal needle positioning was simulated at each insertion (modeled by typical random angulation errors). In 91% of the scenarios, the dose distribution improved when the needle was inserted into the most compared to the least sensitive needle track. The computation time for sequencing was less than 6 s per needle track. The

  18. Design, Fabrication and Initial Testing of a Large Bore Single Aperture 1 m Long Superconducting Dipole Made with Phenolic Inserts

    CERN Document Server

    Boschmann, H; Kirby, G A; Lucas, J; Ostojic, R; Russenschuck, Stephan; Siemko, A; Vanenkov, I; Weterings, W

    1997-01-01

    In the framework of the LHC magnet development programme, a large bore single aperture 1-meter long superconducting dipole has been built in collaboration with HOLEC. The magnet features a single layer coil wound using the LHC main dipole outer layer cable, phenolic inserts, and a keyed two part structural iron yoke. This paper presents the magnetic and mechanical design and optimisation of the magnet. We describe the coil winding and curing, and present the construction and assembly procedures. Finally we report on the mechanical behaviour during assembly and cooling, and present the magnet training behaviour.

  19. [The use of peripherally inserted central catheter (PICC) in patients with hematological malignancies--a single center experience].

    Science.gov (United States)

    Mitrović, Zdravko; Komljenović, Igor; Jaksic, Ozren; Prka, Zeljko; Crnek, Sandra Sestan; Stojsavljević, Radmila Ajduković; Pirsic, Mario; Haris, Visnja; Kusec, Rajko; Dautovic, Diana; Pejsa, Vlatko

    2014-01-01

    AIM. In this study we presented our experience with peripherally inserted central venous catheter (PICC) in patients with hematological malignancies. In the period from 2009 to 2012, a total of 105 PICCs were inserted in 90 patients. Patients with Non-Hodgkin lymphoma treated with DA-EPOCH comprised almost 40% of the cohort. The total PICC in-dwell time was 14781 days with a median of 129 days (range 8-570 days). Malposition of the PICC occurred in 12 patients (11.4%) with a successful reposition or re-insertion. In 39 patients (37%) PICC was removed before the end of treatment due to suspected or proven infection (30 patients, 29%; 2.03 per 1000 PICC days), thrombosis associated with PICC in four patients (3.8%), occlusion of the PICC (two patients), misplaced catheter (two patients), and suspected thromboembolism in a single patient. PICC is a safe and convenient long-term venous access in patients with hematological malignancies.

  20. Synthesis of single-phase L10-FeNi magnet powder by nitrogen insertion and topotactic extraction

    OpenAIRE

    Goto, Sho; Kura, Hiroaki; Watanabe, Eiji; Hayashi, Yasushi; Yanagihara, Hideto; Shimada, Yusuke; Mizuguchi, Masaki; Takanashi, Koki; Kita, Eiji

    2017-01-01

    Tetrataenite (L10-FeNi) is a promising candidate for use as a permanent magnet free of rare-earth elements because of its favorable properties. In this study, single-phase L10-FeNi powder with a high degree of order was synthesized through a new method, nitrogen insertion and topotactic extraction (NITE). In the method, FeNiN, which has the same ordered arrangement as L10-FeNi, is formed by nitriding A1-FeNi powder with ammonia gas. Subsequently, FeNiN is denitrided by topotactic reaction to ...

  1. Supersymmetric contributions to rare kaon decays: beyond the single mass-insertion approximation

    Energy Technology Data Exchange (ETDEWEB)

    Colangelo, G.; Isidori, G. [INFN, Laboratori Nazionali di Frascati, Rome (Italy)

    1998-08-01

    The paper analyzes the contributions to rare kaon decays mediated by flavor-changing Z-penguin diagrams in a generic low-energy supersymmetric extension of the Standard Model. In order to perform a model-independent analysis it was expanded the squark mass matrices around the diagonal, following the so called mass-insertion approximation. It`s argued that in the present case it is necessary to go up to the second order in this expansion to take into account all possible large effects. The current bounds on such second-order term, which was neglected in previous analyses, are discussed in detail and the corresponding upper bounds for the rare kaon decay rates are derived. As a result, it`s shown that supersymmetric effects could lead to large enhancements of K{yields}{pi}{nu}{nu} and K{sub L}{yields}{pi}{sup 0}e{sup +}e{sup -} branching ratios.

  2. Imaging button battery ingestions and insertions in children: a 15-year single-center review

    Energy Technology Data Exchange (ETDEWEB)

    Pugmire, Brian S.; Trout, Andrew T. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Lin, Tom K.; Pentiuk, Scott [Cincinnati Children' s Hospital Medical Center, Division of Gastroenterology Hepatology and Nutrition, Cincinnati, OH (United States); De Alarcon, Alessandro; Hart, Catherine K. [Cincinnati Children' s Hospital Medical Center, Department of Pediatric Otolaryngology, Cincinnati, OH (United States); University of Cincinnati College of Medicine, Department of Otolaryngology-Head and Neck Surgery, Cincinnati, OH (United States)

    2017-02-15

    Recent studies have shown an increase in morbidity associated with button battery ingestions in children. To perform a comprehensive, imaging-focused review of all patients with confirmed button battery ingestions/insertions imaged at our institution in the last 15 years. Radiology reports from Jan. 1, 2000, to July 12, 2015, were searched for the terms ''battery'' and ''batteries.'' Confirmed cases of battery ingestion/insertion for which images were available were reviewed. Cases were reviewed for imaging studies performed, imaging findings, patient demographics, clinical history and management. Two pediatric gastroenterologists reviewed endoscopic images and graded mucosal injuries in selected cases. Two hundred seventy-six cases were reviewed. All patients were imaged with radiography, 19 with fluoroscopy (6.8%), and 4 with CT (1.4%). Batteries retained in the esophagus (n = 27, 9.8%) were larger in diameter on average than those that had passed distally (22.1 ± 3.3 mm vs. 13.7 ± 1.6 mm, P<0.0001). Battery diameter ≥20 mm was associated with esophageal impaction (P<0.0001) and higher grade esophageal injury (P<0.0001). Mean battery diameter was greater for patients with grade 1 or higher mucosal injury than for patients with no mucosal injury (22.1 ± 2.1 mm vs. 14.7 ± 4.5 mm, P<0.0001). Sixteen percent (4/25) of patients with grade ≥1 esophageal injury had batteries in the stomach on initial imaging. Five patients (1.8%) had serious clinical complications (e.g., esophageal perforation, tracheoesophageal fistula). Button batteries >20mm in diameter warrant increased clinical scrutiny due to higher likelihood and severity of injury. Implementation of recent pediatric gastroenterology societal guidelines will likely lead to a substantial increase in the number of CT and MRI examinations. (orig.)

  3. Two-stage IMZ implants and ITI implants inserted in a single-stage procedure. A prospective comparative study.

    Science.gov (United States)

    Heydenrijk, Kees; Raghoebar, Gerry M; Meijer, Henny J A; van der Reijden, Willy A; van Winkelhoff, Arie Jan; Stegenga, Boudewijn

    2002-08-01

    The aim of this study was to evaluate the feasibility of using a two-stage implant system in a single-stage procedure and to study the impact of the microgap at crestal level and to monitor the microflora in the peri-implant area. Forty edentulous patients (Cawood & Howell class V-VI) participated in this study. After randomisation, 20 patients received two IMZ implants inserted in a single-stage procedure and 20 patients received two ITI implants. After 3 months, overdentures were fabricated, supported by a bar and clip attachment. A standardised clinical and radiographic evaluation was performed immediately after denture insertion and 6 and 12 months later. Twelve months after loading, peri-implant samples were collected with sterile paper points and analysed for the presence of putative periodontal pathogens using culture techniques. One IMZ implant was lost due to insufficient osseointegration. With regard to the clinical parameters at the 12 months evaluation, significant differences for plaque score and probing pocket depth (IMZ: mean 3.3 mm, ITI: mean 2.9 mm) were found between the two groups. The mean bone loss in the first year of functioning was 0.6 mm for both groups. Prevotella intermedia was detected more often in the ITI group (12 implants) than in the IMZ group (three implants). Porphyromonas gingivalis was found in three patients. In one of these patients an implant showed bone loss of 1.6 mm between T0 and T12. Some associations were found between clinical parameters and the target microorganisms in the ITI group. These associations were not present in the IMZ group. The short-term results indicate that two-stage implants inserted in a single-stage procedure may be as predictable as one-stage implants. The microgap at crestal level in nonsubmerged IMZ implants seems to have no adverse influence on the peri-implant microbiological colonisation and of crestal bone loss in the first year of functioning. The peri-implant sulcus can and does harbour

  4. Insertion of Short Amino-Functionalized Single-Walled Carbon Nanotubes into Phospholipid Bilayer Occurs by Passive Diffusion

    Science.gov (United States)

    Kraszewski, Sebastian; Bianco, Alberto; Tarek, Mounir; Ramseyer, Christophe

    2012-01-01

    Carbon nanotubes have been proposed to be efficient nanovectors able to deliver genetic or therapeutic cargo into living cells. However, a direct evidence of the molecular mechanism of their translocation across cell membranes is still needed. Here, we report on an extensive computational study of short (5 nm length) pristine and functionalized single-walled carbon nanotubes uptake by phospholipid bilayer models using all-atom molecular dynamics simulations. Our data support the hypothesis of a direct translocation of the nanotubes through the phospholipid membrane. We find that insertion of neat nanotubes within the bilayer is a “nanoneedle” like process, which can often be divided in three consecutive steps: landing and floating, penetration of the lipid headgroup area and finally sliding into the membrane core. The presence of functional groups at moderate concentrations does not modify the overall scheme of diffusion mechanism, provided that their deprotonated state favors translocation through the lipid bilayer. PMID:22815794

  5. Single Amino Acid Insertion in Loop 4 Confers Amphotropic Murine Leukemia Virus Receptor Function upon Murine Pit1

    DEFF Research Database (Denmark)

    Lundorf, Mikkel D.; Pedersen, Finn Skou; O'Hara, Bryan

    1998-01-01

    Pit1 is the human receptor for gibbon ape leukemia virus (GALV) and feline leukemia virus subgroup B (FeLV-B), while the related human protein Pit2 is a receptor for amphotropic murine leukemia virus (A-MuLV). The A-MuLV-related isolate 10A1 can utilize both Pit1 and Pit2 as receptors. A stretch...... of amino acids named region A was identified in Pit1 (residues 550 to 558 in loop 4) as critical for GALV and FeLV-B receptor function. We have here investigated the role of region A in A-MuLV and 10A1 entry. Insertion of a single amino acid in region A of mouse Pit1 resulted in a functional A...

  6. A DFT Mechanistic Study on Ethylene Tri- and Tetramerization with Cr/PNP Catalysts: Single versus Double Insertion Pathways.

    Science.gov (United States)

    Britovsek, George J P; McGuinness, David S

    2016-11-14

    The mechanism of ethylene trimerization and tetramerization with a chromium-diphosphinoamine (Cr-PNP) catalyst system has been studied by theoretical (DFT) methods. Two representative ligands have been explored, namely Ph 2 PN(Me)PPh 2 and (o-MeC 6 H 4 ) 2 PN(Me)P(o-MeC 6 H 4 ) 2 . Calculations on the former ligand reveal how a combination of single and double ethylene insertion mechanisms may lead to 1-hexene, 1-octene and the major side products (cyclopentanes and n-alkanes). For the latter ligand, introduction of o-alkyl substitution leads to a more sterically congested active species, which suppresses the available pathways for tetramerization and side product formation. Hence, the high selectivity of o-aryl substituted PNP ligands for trimerization can be rationalized. © 2016 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. PERIPHERALLY INSERTED CENTRAL VENOUS CATHETER SAFETYIN BURN CARE: A SINGLE CENTRE RETROSPECTIVE COHORT REVIEW

    Science.gov (United States)

    Austin, Ryan E.; Shahrokhi, Shahriar; Bolourani, Siavash; Jeschke, Marc G.

    2014-01-01

    Objective PICC line use for central venous access in thermally injured patients has increased in recent years despite a lack of evidence regarding safety in this patient population. A recent survey of invasive catheter practices among 44 burn centers in the United States found that 37% of burn units use PICC lines as part of their treatment protocol. The goal of this study was to compare PICC associated complication rates to existing literature in both the critical care and burn settings. Methods A single institution retrospective cohort review of patients who received a PICC line during admission to a regional burn unit between 2008–2013. Fifty-three patients were identified with a total of seventy-three PICC lines. The primary outcome measurement for this study was indication for PICC line discontinuation. Results The most common reason for PICC line discontinuation was that the line was no longer indicated (45.2%). Four cases of symptomatic upper extremity deep vein thrombosis (5.5%) and 3 cases of central line associated bloodstream infection (4.3%, 2.72 infections per 1000 line days) were identified. PICC lines were in situ an average of 15 days [range 1–49 days]. Conclusions We suggest that PICC line associated complication rates are similar to those published in the critical care literature. Though these rates are higher than those published in the burn literature, they are similar to CVC associated complication rates. While PICC lines can be a useful resource in the treatment of the thermally injured patient, they are associated with significant, and potentially fatal risks. PMID:25501778

  8. Synthesis of single-phase L10-FeNi magnet powder by nitrogen insertion and topotactic extraction.

    Science.gov (United States)

    Goto, Sho; Kura, Hiroaki; Watanabe, Eiji; Hayashi, Yasushi; Yanagihara, Hideto; Shimada, Yusuke; Mizuguchi, Masaki; Takanashi, Koki; Kita, Eiji

    2017-10-16

    Tetrataenite (L1 0 -FeNi) is a promising candidate for use as a permanent magnet free of rare-earth elements because of its favorable properties. In this study, single-phase L1 0 -FeNi powder with a high degree of order was synthesized through a new method, nitrogen insertion and topotactic extraction (NITE). In the method, FeNiN, which has the same ordered arrangement as L1 0 -FeNi, is formed by nitriding A1-FeNi powder with ammonia gas. Subsequently, FeNiN is denitrided by topotactic reaction to derive single-phase L1 0 -FeNi with an order parameter of 0.71. The transformation of disordered-phase FeNi into the L1 0 phase increased the coercive force from 14.5 kA/m to 142 kA/m. The proposed method not only significantly accelerates the development of magnets using L1 0 -FeNi but also offers a new synthesis route to obtain ordered alloys in non-equilibrium states.

  9. Single-Camera Closed-Form Real-Time Needle Tracking for Ultrasound-Guided Needle Insertion.

    Science.gov (United States)

    Najafi, Mohammad; Abolmaesumi, Purang; Rohling, Robert

    2015-10-01

    Many common needle intervention procedures are performed with ultrasound guidance because it is a flexible, cost-effective and widely available intra-operative imaging modality. In a needle insertion procedure with ultrasound guidance, real-time calculation and visualization of the needle trajectory can help to guide the choice of puncture site and needle angle to reach the target depicted in the ultrasound image. We found that it is feasible to calculate the needle trajectory with a single camera mounted directly on the ultrasound transducer by using the needle markings. Higher accuracy is achieved compared with other similar transducer-mounted needle trackers. We used an inexpensive, real-time and easy-to-use tracking method based on an automatic feature extraction algorithm and a closed-form method for pose estimation of the needle. The overall accuracy was 0.94 ± 0.46 mm. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  10. Outcomes of inferior vena cava filter insertion in patients with lower extremity deep vein thrombosis for prevention of pulmonary thromboembolism: A single center retrospective analysis

    International Nuclear Information System (INIS)

    Park, Byung Jin; Kim, Jae Kyu; Yim, Nam Yeol; Kim, Hyoung Ook; Kang, Yang Jun

    2017-01-01

    To evaluate the mid- and long-term outcomes of inferior vena cava (IVC) filter insertion in patients with underlying deep vein thrombosis for prevention of pulmonary thromboembolism, based on a single center experience. A total of 166 IVC filter insertion procedures in 160 patients, between February 2004 and December 2014, were retrospectively reviewed. Severity of deep vein thrombosis, indwelling time of the IVC filter, retrieval rate, and complication rate depending on the type of IVC filter were analyzed based on the patients' radiologic findings and medical records. IVC filter insertion procedures were successfully performed in all patients. Among the 99 attempts at filter retrieval, 91 trials succeeded (91.9%, 91/99) and 8 trials failed. Indwelling time of the IVC filter showed a positive correlation with failure of filter retrieval (p = 0.01). There was no procedure-related complication after all IVC filter insertion procedures. Eight delayed complications (5.0%, 8/160 patients with IVC filter insertion) were observed [caval thrombosis below the IVC filter (n = 7) and IVC penetration (n = 1)]. Günther Tulip filter was associated with a significant incidence of complication (p = 0.036). IVC filter insertion in patients with lower extremity deep vein thrombosis for prevention of pulmonary thromboembolism can be regarded as a safe treatment modality with an acceptable complication rate

  11. Outcomes of inferior vena cava filter insertion in patients with lower extremity deep vein thrombosis for prevention of pulmonary thromboembolism: A single center retrospective analysis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Byung Jin; Kim, Jae Kyu; Yim, Nam Yeol; Kim, Hyoung Ook [Dept. of Radiology, Chonnam National University Hospital, Gwangju (Korea, Republic of); Kang, Yang Jun [Dept. of Radiology, Chonnam National University Hwasun Hospital, Hwasun (Korea, Republic of)

    2017-07-15

    To evaluate the mid- and long-term outcomes of inferior vena cava (IVC) filter insertion in patients with underlying deep vein thrombosis for prevention of pulmonary thromboembolism, based on a single center experience. A total of 166 IVC filter insertion procedures in 160 patients, between February 2004 and December 2014, were retrospectively reviewed. Severity of deep vein thrombosis, indwelling time of the IVC filter, retrieval rate, and complication rate depending on the type of IVC filter were analyzed based on the patients' radiologic findings and medical records. IVC filter insertion procedures were successfully performed in all patients. Among the 99 attempts at filter retrieval, 91 trials succeeded (91.9%, 91/99) and 8 trials failed. Indwelling time of the IVC filter showed a positive correlation with failure of filter retrieval (p = 0.01). There was no procedure-related complication after all IVC filter insertion procedures. Eight delayed complications (5.0%, 8/160 patients with IVC filter insertion) were observed [caval thrombosis below the IVC filter (n = 7) and IVC penetration (n = 1)]. Günther Tulip filter was associated with a significant incidence of complication (p = 0.036). IVC filter insertion in patients with lower extremity deep vein thrombosis for prevention of pulmonary thromboembolism can be regarded as a safe treatment modality with an acceptable complication rate.

  12. Insertion sequence element single nucleotide polymorphism typing provides insights into the population structure and evolution of Mycobacterium ulcerans across Africa.

    Science.gov (United States)

    Vandelannoote, Koen; Jordaens, Kurt; Bomans, Pieter; Leirs, Herwig; Durnez, Lies; Affolabi, Dissou; Sopoh, Ghislain; Aguiar, Julia; Phanzu, Delphin Mavinga; Kibadi, Kapay; Eyangoh, Sara; Manou, Louis Bayonne; Phillips, Richard Odame; Adjei, Ohene; Ablordey, Anthony; Rigouts, Leen; Portaels, Françoise; Eddyani, Miriam; de Jong, Bouke C

    2014-02-01

    Buruli ulcer is an indolent, slowly progressing necrotizing disease of the skin caused by infection with Mycobacterium ulcerans. In the present study, we applied a redesigned technique to a vast panel of M. ulcerans disease isolates and clinical samples originating from multiple African disease foci in order to (i) gain fundamental insights into the population structure and evolutionary history of the pathogen and (ii) disentangle the phylogeographic relationships within the genetically conserved cluster of African M. ulcerans. Our analyses identified 23 different African insertion sequence element single nucleotide polymorphism (ISE-SNP) types that dominate in different areas where Buruli ulcer is endemic. These ISE-SNP types appear to be the initial stages of clonal diversification from a common, possibly ancestral ISE-SNP type. ISE-SNP types were found unevenly distributed over the greater West African hydrological drainage basins. Our findings suggest that geographical barriers bordering the basins to some extent prevented bacterial gene flow between basins and that this resulted in independent focal transmission clusters associated with the hydrological drainage areas. Different phylogenetic methods yielded two well-supported sister clades within the African ISE-SNP types. The ISE-SNP types from the "pan-African clade" were found to be widespread throughout Africa, while the ISE-SNP types of the "Gabonese/Cameroonian clade" were much rarer and found in a more restricted area, which suggested that the latter clade evolved more recently. Additionally, the Gabonese/Cameroonian clade was found to form a strongly supported monophyletic group with Papua New Guinean ISE-SNP type 8, which is unrelated to other Southeast Asian ISE-SNP types.

  13. A 1204-single nucleotide polymorphism and insertion-deletion polymorphism panel for massively parallel sequencing analysis of DNA mixtures.

    Science.gov (United States)

    Hwa, Hsiao-Lin; Chung, Wan-Chia; Chen, Pei-Lung; Lin, Chih-Peng; Li, Huei-Ying; Yin, Hsiang-I; Lee, James Chun-I

    2018-01-01

    Massively parallel sequencing (MPS) technology enables the simultaneous analysis of a huge number of single nucleotide polymorphisms (SNPs) and insertion-deletion polymorphisms (indels). MPS also enables the detection of the alleles of minor contributors in a highly unbalanced DNA mixture. In this study, we established a 1204-marker panel optimized for MPS consisting of 987 autosomal markers (964 SNPs and 23 indels), 27 X-chromosome SNPs, 61 Y-chromosome markers (56 SNPs and 5 indels), and 129 mitochondrial SNPs. The DNA samples of six unrelated individuals (two men and four women), 26 nondegraded DNA mixtures (with minor to major ratios of 1:29, 1:39, 1:79, and 1:99), and eight highly artificially degraded DNA mixtures (with minor to major ratios of 1:29, 1:39, 1:79, and 1:99) were analyzed through MPS by using the panel. A scoring system was developed to determine the minor contributors in DNA mixtures based on the genotypes identified using MPS. The genotypes of the 1204 markers were successfully profiled through MPS by using the custom-designed panel. The efficiency of MPS for analyzing these highly degraded samples was lower than that for analyzing nondegraded samples. All minor contributors in the 26 nondegraded and 8 degraded DNA mixtures were accurately assigned using this scoring system based on 964 autosomal SNPs. An association between the observed reads ratio and theoretical ratio of the minor component was noted for nondegraded mixtures. In conclusion, we established a 1204-marker individual identification panel for MPS that successfully analyzed autosomal, X-chromosome, Y-chromosome, and mitochondrial SNPs and indels simultaneously. In combination with the newly developed scoring system, the panel can accurately identify minor contributors in nondegraded and highly degraded DNA mixtures. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Digital assistance of nasogastric tube insertion in intubated patients under general anesthesia: A single-blinded prospective randomized study

    Science.gov (United States)

    Kandeel, Alrefaey; Elmorhedi, Mohammed; Abdalla, Usama

    2017-01-01

    Background: Nasogastric tube (NGT) insertion may pose a special problem in patients under general anesthesia with first attempt failure rates up to 50%. To increase insertion success rate and decreases related complications, several techniques have been developed. In this study, digital assistance technique is compared to the classic insertion technique in neck flexion. Materials and Methods: In this prospective randomized study, 160 patients were randomly allocated into two groups; control group (Group C, n = 80) where NGT tube will be inserted with the neck in flexion position and digital facilitation group (Group D, n = 80). Results: Overall success rate and first attempt success were statistically higher in Group D compared to Group C (94% vs. 81%, P = 0.02, 80% vs. 62%, P = 0.01 respectively) with significantly lower insertion time in Group D (13 ± 5 s. vs. 10 ± 3 s., P = 0.00). Conclusions: Digital assistance of NGT insertion in the anesthetized or unconscious patient is an effective, fast, and safe method that can be either used as a routine technique or as a rescue in case of failed other methods. PMID:28757827

  15. CRISPR/Cas9-induced transgene insertion and telomere-associated truncation of a single human chromosome for chromosome engineering in CHO and A9 cells.

    Science.gov (United States)

    Uno, Narumi; Hiramatsu, Kei; Uno, Katsuhiro; Komoto, Shinya; Kazuki, Yasuhiro; Oshimura, Mitsuo

    2017-10-06

    Chromosome engineering techniques including gene insertion, telomere-associated truncation and microcell-mediated chromosome transfer (MMCT) are powerful tools for generation of humanised model animal, containing megabase-sized genomic fragments. However, these techniques require two cell lines: homologous recombination (HR)-proficient DT40 cells for chromosome modification, and CHO cells for transfer to recipient cells. Here we show an improved technique using a combination of CRISPR/Cas9-induced HR in CHO and mouse A9 cells without DT40 cells following MMCT to recipient cells. Transgene insertion was performed in CHO cells with the insertion of enhanced green fluorescence protein (EGFP) using CRISPR/Cas9 and a circular targeting vector containing two 3 kb HR arms. Telomere-associated truncation was performed in CHO cells using CRISPR/Cas9 and a linearised truncation vector containing a single 7 kb HR arm at the 5' end, a 1 kb artificial telomere at the 3' end. At least 11% and 6% of the targeting efficiency were achieved for transgene insertion and telomere-associated truncation, respectively. The transgene insertion was also confirmed in A9 cells (29%). The modified chromosomes were transferrable to other cells. Thus, this CHO and A9 cell-mediated chromosome engineering using the CRISPR/Cas9 for direct transfer of the modified chromosome is a rapid technique that will facilitate chromosome manipulation.

  16. Percutaneous insertion of peritoneal dialysis catheters using ultrasound and fluoroscopic guidance: A single centre experience and review of literature

    International Nuclear Information System (INIS)

    De Boo, Diederick W.; Mott, Nigel; Tregaskis, Peter; Quach, Trung; Menahem, Solomon; Walker, Rowan G.; Koukounaras, Jim

    2015-01-01

    Various methods of peritoneal dialysis (PD) catheter insertion are available. The purpose of this study was to evaluate a percutaneous insertion technique using ultrasound (US) and fluoroscopy performed under conscious sedation and as day case procedure. Data of 87 percutaneous inserted dialysis catheters were prospectively collected, including patients' age, gender, body mass index, history of previous abdominal surgery and cause of end stage renal failure. Length of hospital stay, early complications and time to first use were also recorded. Institutional review board approval was obtained. A 100% technical success rate was observed. Early complications included bleeding (n = 3), catheter dysfunction (n = 6), exit site infection (n = 1) and exit site leakage (n = 1). All cases of catheter dysfunction and one case of bleeding required surgical revision. Median time of follow-up was 18 months (range 3–35), and median time from insertion to first use was days 14 (1–47). Of the 82 patients who started dialysis, 20 (23%) ceased PD at some stage during follow-up. Most frequently encountered reasons include deteriorating patient cognitive or functional status (n = 5), successful transplant kidney (n = 4) and pleuro-peritoneal fistula (n = 4). Sixty-two (71%) PD catheter insertions were performed as day case. The remaining insertions were performed on patients already admitted to the hospital. Percutaneous insertion of dialysis catheter using US and fluoroscopy is not only safe but can be performed as day case procedure in most patients, even with a medical history of abdominal surgery and/or obesity.

  17. V-cut twisted tape insert effect on heat transfer enhancement of single phase turbulent flow heat exchanger

    Science.gov (United States)

    Yaningsih, Indri; Wijayanta, Agung Tri; Miyazaki, Takahiko; Koyama, Shigeru

    2018-02-01

    Turbulator is recognized as a method to increase the performance of the heat exchanger. Turbulator in the form of V-cut twisted tape insert could help to increase the performance by enhancing the coefficient of the heat transfer. This paper proposes a new design of V-cut twisted tape insert (VTT) with different width ratio (w/W), which investigated on the heat transfer enhancement, in the form of Nusselt number (Nu) and friction factor (f) characteristics. Three different width ratios (w/W) 0.32; 0.38 and 0.48 are introduced in this experiment. The working fluid is the hot water in the inner tube and cold water in the annulus, the flow direction is counter-flow. The temperature inlet of hot water is kept constant at 60°C while the flow rate is in the range of Reynolds number 5400 - 17,350. The heat exchanger without insertion (plain tube) and typical twisted tape insert (TT) are examined for comparison. Results indicate that the proposed VTT increases the heat transfer, friction factor, and thermal performance of the heat exchanger. Under the similar condition, VTT provides the best performance in comparison with TT and plain tube. Decreasing width ratio (w/W) increases the heat transfer and thermal performance. However, when the heat transfer is increased, the friction factor is also increasing. The results also revealed that the use of the VTT and TT, the increase in the heat transfer and friction factor up to 97% and 3.48 times of the plain tube. The highest thermal performance is 1.4.

  18. Coexistence of optically active radial and axial CdTe insertions in single ZnTe nanowire

    Science.gov (United States)

    Wojnar, P.; Płachta, J.; Zaleszczyk, W.; Kret, S.; Sanchez, Ana M.; Rudniewski, R.; Raczkowska, K.; Szymura, M.; Karczewski, G.; Baczewski, L. T.; Pietruczik, A.; Wojtowicz, T.; Kossut, J.

    2016-03-01

    We report on the growth, cathodoluminescence and micro-photoluminescence of individual radial and axial CdTe insertions in ZnTe nanowires. In particular, the cathodoluminescence technique is used to determine the position of each emitting object inside the nanowire. It is demonstrated that depending on the CdTe deposition temperature, one can obtain an emission either from axial CdTe insertions only, or from both, radial and axial heterostructures, simultaneously. At 350 °C CdTe grows only axially, whereas at 310 °C and 290 °C, there is also significant deposition on the nanowire sidewalls resulting in radial core/shell heterostructures. The presence of Cd atoms on the sidewalls is confirmed by energy dispersive X-ray spectroscopy. Micro-photoluminescence study reveals a strong linear polarization of the emission from both types of heterostructures in the direction along the nanowire axis.We report on the growth, cathodoluminescence and micro-photoluminescence of individual radial and axial CdTe insertions in ZnTe nanowires. In particular, the cathodoluminescence technique is used to determine the position of each emitting object inside the nanowire. It is demonstrated that depending on the CdTe deposition temperature, one can obtain an emission either from axial CdTe insertions only, or from both, radial and axial heterostructures, simultaneously. At 350 °C CdTe grows only axially, whereas at 310 °C and 290 °C, there is also significant deposition on the nanowire sidewalls resulting in radial core/shell heterostructures. The presence of Cd atoms on the sidewalls is confirmed by energy dispersive X-ray spectroscopy. Micro-photoluminescence study reveals a strong linear polarization of the emission from both types of heterostructures in the direction along the nanowire axis. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr08806b

  19. A single base insertion in the putative transmembrane domain of the tyrosinase gene as a cause for tyrosinase-negative oculocutaneous albinism

    Energy Technology Data Exchange (ETDEWEB)

    Chintamaneni, C.D.; Kobayashi, Y.; Kwon, B.S. (Indiana Univ. School of Medicine, Indianapolis (United States)); Halaban, R. (Yale Univ. School of Medicine, New Haven, CT (United States)); Witkop, C.J. Jr. (Univ. of Minnesota, Minneapolis (United States))

    1991-06-15

    The authors have determined a molecular defect to be the likely basis for inactivity of the tyrosinase from a patient with tyrosinase-negative oculocutaneous albinism. A single base (thymine) was inserted in exon 5 of the tyrosinase gene following codon 471 in the putative transmembrane coding region. This insertion caused a shift in the reading frame of 19 amino acids at the 3{prime} end and introduced a premature termination signal that would be expected to truncate the protein by 21 amino acids at the carboxyl terminus. The albino tyrosinase was not recognized by antibodies directed to the carboxyl terminus of tyrosinase. Furthermore, as shown by gel electrophoresis of the immunoprecipitated protein, the tyrosinase was {approx} 3kDa smaller than normal. Similar immunoprecipitation data were obtained when cloned normal and mutant tyrosinases were expressed in COS-1 cells.

  20. Relationship between external ventricular drain clamp trials and ventriculoperitoneal shunt insertion following nontraumatic subarachnoid hemorrhage: a single-center study.

    Science.gov (United States)

    Ascanio, Luis C; Gupta, Raghav; Adeeb, Nimer; Moore, Justin M; Griessenauer, Christoph J; Mayeku, Julie; Tachie-Baffour, Yaw; Thomas, Ranjit; Alturki, Abdulrahman Y; Schmalz, Philip G R; Ogilvy, Christopher S; Thomas, Ajith J

    2018-03-16

    OBJECTIVE Currently, there is no established standard regarding the ideal number of external ventricular drain (EVD) clamp trials performed before ventriculoperitoneal (VP) shunt insertion following nontraumatic subarachnoid hemorrhage (SAH). In this study, the authors aimed to evaluate this relationship. METHODS A retrospective review of all patients presenting with SAH between July 2007 and December 2016 was performed. Patients with SAH who had received an EVD within the first 24 hours of hospital admission and had undergone at least 1 clamp trial prior to EVD removal were eligible for inclusion in the study. Patient demographics, clinical presentations, SAH etiologies and grades, clamp trial data, hospital lengths of stay, and functional outcomes were recorded. RESULTS One hundred fourteen patients with nontraumatic SAH complicated by posthemorrhagic hydrocephalus were included in the study. The median patient age was 57 years (range 28-90 years), with a male/female ratio of 1:1.7. A ruptured aneurysm was the underlying etiology of SAH in 79.8% of patients. A majority of patients (69.4%) had a Hunt and Hess grade III-V on admission. The median number of clamp trials performed was 2 (range 1-6). A VP shunt was required in 40.4% of patients. In those who underwent 2 and 3 clamp trials, 60% and 38.9%, respectively, did not require subsequent VP shunt placement. CONCLUSIONS Surgical placement of a VP shunt is associated with complications. Clamp trials are routinely performed before making the decision to insert a shunt. In the present study, the authors found that a significant percentage of patients passed their second and third clamp trials without requiring subsequent shunt insertion. These data support performing multiple clamp trials prior to shunt placement.

  1. Identification of a single-nucleotide insertion in the promoter region affecting the sodC promoter activity in Brucella neotomae.

    Directory of Open Access Journals (Sweden)

    Dina A Moustafa

    Full Text Available Brucella neotomae is not known to be associated with clinical disease in any host species. Previous research suggested that B. neotomae might not express detectable levels of Cu/Zn superoxide dismutase (SOD, a periplasmic enzyme known to be involved in protecting Brucella from oxidative bactericidal effects of host phagocytes. This study was undertaken to investigate the genetic basis for the disparity in SOD expression in B. neotomae. Our Western blot and SOD enzyme assay analyses indicated that B. neotomae does express SOD, but at a substantially reduced level. Nucleotide sequence analysis of region upstream to the sodC gene identified a single-nucleotide insertion in the potential promoter region. The same single-nucleotide insertion was also detected in the sodC promoter of B. suis strain Thomsen, belonging to biovar 2 in which SOD expression was undetectable previously. Examination of the sodC promoter activities using translational fusion constructs with E. coli β-galactosidase demonstrated that the B. neotomae and B. suis biovar 2 promoters were very weak in driving gene expression. Site-directed mutation studies indicated that the insertion of A in the B. neotomae sodC promoter reduced the promoter activity. Increasing the level of SOD expression in B. neotomae through complementation with B. abortus sodC gene did not alter the bacterial survival in J774A.1 macrophage-like cells and in tissues of BALB/c and C57BL/6 mice. These results for the first time demonstrate the occurrence of a single-nucleotide polymorphism affecting promoter function and gene expression in Brucella.

  2. Experimental insertions

    International Nuclear Information System (INIS)

    Sandweiss, J.; Kycia, T.F.

    1975-01-01

    A discussion is given of the eight identical experimental insertions for the planned ISABELLE storage rings. Four sets of quadrupole doublets are used to match the β functions in the insertions to the values in the cells, and the total free space available at the crossing point is 40 meters. An asymmetric beam energy operation is planned, which will be useful in a number of experiments

  3. Retrospective application of transposon-directed insertion site sequencing to a library of signature-tagged mini-Tn5Km2 mutants of Escherichia coli O157:H7 screened in cattle.

    Science.gov (United States)

    Eckert, Sabine E; Dziva, Francis; Chaudhuri, Roy R; Langridge, Gemma C; Turner, Daniel J; Pickard, Derek J; Maskell, Duncan J; Thomson, Nicholas R; Stevens, Mark P

    2011-04-01

    Massively parallel sequencing of transposon-flanking regions assigned the genotype and fitness score to 91% of Escherichia coli O157:H7 mutants previously screened in cattle by signature-tagged mutagenesis (STM). The method obviates the limitations of STM and markedly extended the functional annotation of the prototype E. coli O157:H7 genome without further animal use.

  4. Randomized controlled trial comparing different single doses of intravenous paracetamol for placement of peripherally inserted central catheters in preterm infants

    NARCIS (Netherlands)

    D.W.E. Roofthooft (Daniella); S.H. Simons (Sinno); R.A. Lingen (Richard); D. Tibboel (Dick); J.N. van den Anker (John); I.K.M. Reiss (Irwin); M. van Dijk (Monique)

    2017-01-01

    markdownabstract__Background:__ The availability of a safe and effective pharmacological therapy to reduce procedural pain in preterm infants is limited. The effective analgesic single dose of intravenous paracetamol in preterm infants is unknown. Comparative studies on efficacy of different

  5. Peripherally inserted central catheter - insertion

    Science.gov (United States)

    PICC - insertion ... A PICC is a long, thin tube (called a catheter) that goes into your body through a vein in ... into a large vein near your heart. The PICC helps carry nutrients and medicines into your body. ...

  6. Two-stage IMZ implants and ITI implants inserted in a single-stage procedure : A prospective comparative study

    NARCIS (Netherlands)

    Heydenrijk, Kees; Raghoebar, Gerry M.; Meijer, Henny J.A.; Reijden, Willy A. van der; Winkelhoff, Arie Jan van; Stegenga, Boudewijn

    2002-01-01

    The aim of this study was to evaluate the feasibility of using a two-stage implant system in a single-stage procedure and to study the impact of the microgap at crestal level and to monitor the microflora in the peri-implant area. Forty edentulous patients (Cawood & Howell class V–VI) participated

  7. Two-stage IMZ implants and ITI implants inserted in a single-stage procedure - A prospective comparative study

    NARCIS (Netherlands)

    Heydenrijk, K; Raghoebar, GM; Meijer, HJA; van der Reijden, WA; van Winkelhoff, AJ; Stegenga, B

    The aim of this study was to evaluate the feasibility of using a two-stage implant system in a single-stage procedure and to study the impact of the microgap at crestal level and to monitor the microflora in the peri-implant area. Forty edentulous patients (Cawood & Howell class V-VI) participated

  8. Learning curves for insertion

    African Journals Online (AJOL)

    Adele

    Introduction. Both the Unique™ LMA, and lately the Cobra™ PLA, is available in most of the larger state hospitals in South Africa. This study's objective is to evaluate and compare the learning curves for insertion of these two single-use airway devices. This is to ascertain which of these two devices is easier and safer to ...

  9. SU-E-J-104: Single Photon Image From PET with Insertable SPECT Collimator for Boron Neutron Capture Therapy: A Feasibility Study

    International Nuclear Information System (INIS)

    Jung, J; Yoon, D; Suh, T; Hong, K

    2014-01-01

    Purpose: The aim of our proposed system is to confirm the feasibility of extraction of two types of images from one positron emission tomography (PET) module with an insertable collimator for brain tumor treatment during the BNCT. Methods: Data from the PET module, neutron source, and collimator was entered in the Monte Carlo n-particle extended (MCNPX) source code. The coincidence events were first compiled on the PET detector, and then, the events of the prompt gamma ray were collected after neutron emission by using a single photon emission computed tomography (SPECT) collimator on the PET. The obtaining of full width at half maximum (FWHM) values from the energy spectrum was performed to collect effective events for reconstructed image. In order to evaluate the images easily, five boron regions in a brain phantom were used. The image profiles were extracted from the region of interest (ROI) of a phantom. The image was reconstructed using the ordered subsets expectation maximization (OSEM) reconstruction algorithm. The image profiles and the receiver operating characteristic (ROC) curve were compiled for quantitative analysis from the two kinds of reconstructed image. Results: The prompt gamma ray energy peak of 478 keV appeared in the energy spectrum with a FWHM of 41 keV (6.4%). On the basis of the ROC curve in Region A to Region E, the differences in the area under the curve (AUC) of the PET and SPECT images were found to be 10.2%, 11.7%, 8.2% (center, Region C), 12.6%, and 10.5%, respectively. Conclusion: We attempted to acquire the PET and SPECT images simultaneously using only PET without an additional isotope. Single photon images were acquired using an insertable collimator on a PET detector. This research was supported by the Leading Foreign Research Institute Recruitment Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, Information and Communication Technologies (ICT) and Future Planning (MSIP)(Grant No

  10. SU-E-T-263: Point Dose Variation Using a Single Ir-192 HDR Brachytherapy Plan for Two Treatments with a Single Tandem-Ovoid Insertion for Cervical Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Liang, X; Morrill, S; Hardee, M; Han, E; Penagaricano, J; Zhang, X; Vaneerat, R [University of Arkansas Medical Science, Little Rock, AR (United States)

    2014-06-01

    Purpose: To evaluate the point dose variations between Ir-192 HDR treatments on two consecutive days using a single tandem-ovoid insertion without replanning in cervical cancer patients. Methods: This study includes eleven cervical cancer patients undergoing HDR brachytherapy with a prescribed dose of 28 Gy in 4 fractions. Each patient had two tandemovoid insertions one week apart. Each insertion was treated on consecutive days with rescanning and replanning prior to each treatment. To study the effect of no replanning for day 2 treatments, the day 1 plan dwell position and dwell time with decay were applied to the day 2 CT dataset. The point dose variations on the prescription point H (defined according to American Brachytherapy Society), and normal tissue doses at point B, bladder, rectum and vaginal mucosa (based on ICRU Report 38) were obtained. Results: Without replanning, the mean point H dose variation was 4.6 ± 10.7% on the left; 2.3 ± 2.9% on the right. The mean B point variation was 3.8 ± 4.9% on the left; 3.6 ± 4.7% on the right. The variation in the left vaginal mucosal point was 12.2 ± 10.7%; 9.5 ± 12.5% on the right; the bladder point 5.5 ± 7.4%; and the rectal point 7.9 ± 9.1%. Conclusion: Without replanning, there are variations both in the prescription point and the normal tissue point doses. The latter can vary as much as 10% or more. This is likely due to the steep dose gradient from brachytherapy compounded by shifts in the positions of the applicator in relationship to the patients anatomy. Imaging prior to each treatment and replanning ensure effective and safe brachytherapy are recommended.

  11. Skin antisepsis with 0.05% sodium hypochlorite before central venous catheter insertion in neonates: A 2-year single-center experience.

    Science.gov (United States)

    Ciccia, Matilde; Chakrokh, Roksana; Molinazzi, Dario; Zanni, Angela; Farruggia, Patrizia; Sandri, Fabrizio

    2018-02-01

    The study reports a 2-year single-center experience of the practice of skin antisepsis using a 0.05% sodium hypochlorite solution before central venous catheter placement in neonates. Eligible subjects included any hospitalized neonate who needed a central line for at least 48 hours. Infants were excluded if they had a generalized or localized skin disorder. An ad hoc Excel (Microsoft Corp, Redmond, WA) file was used to record the data from each patient. The catheter sites were monitored daily for the presence of contact dermatitis. Central line-associated bloodstream infection was diagnosed according to Centers for Disease Control and Prevention definition. One hundred five infants underwent central venous catheter placement and were enrolled. A total of 198 central lines were inserted. The median gestational age was 31 weeks (range, 23-41 weeks) and median birth weight was 1,420 g (range, 500-5,170 g). There were no signs of 0.05% sodium hypochlorite-related skin toxicity in any infant. Of 198 catheters (1,652 catheter-days) prospectively studied, 9 were associated with bloodstream infections (5.4 per 1,000 catheter-days). During the observation period, no local adverse effects were observed suggesting that 0.05% sodium hypochlorite may be a safe choice in this context. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  12. Insertion of a single-molecule magnet inside a ferromagnetic lattice based on a 3D bimetallic oxalate network: towards molecular analogues of permanent magnets.

    Science.gov (United States)

    Clemente-León, Miguel; Coronado, Eugenio; Gómez-García, Carlos J; López-Jordà, Maurici; Camón, Agustín; Repollés, Ana; Luis, Fernando

    2014-02-03

    The insertion of the single-molecule magnet (SMM) [Mn(III)(salen)(H2O)]2(2+) (salen(2-) = N,N'-ethylenebis-(salicylideneiminate)) into a ferromagnetic bimetallic oxalate network affords the hybrid compound [Mn(III)(salen)(H2O)]2[Mn(II)Cr(III)(ox)3]2⋅(CH3OH)⋅(CH3CN)2 (1). This cationic Mn2 cluster templates the growth of crystals formed by an unusual achiral 3D oxalate network. The magnetic properties of this hybrid magnet are compared with those of the analogous compounds [Mn(III)(salen)(H2O)]2[Zn(II)Cr(III)(ox)3]2⋅(CH3OH)⋅(CH3CN)2 (2) and [In(III)(sal2-trien)][Mn(II)Cr(III)(ox)3]⋅(H2O)0.25⋅(CH3OH)0.25⋅(CH3CN)0.25 (3), which are used as reference compounds. In 2 it has been shown that the magnetic isolation of the Mn2 clusters provided by their insertion into a paramagnetic oxalate network of Cr(III) affords a SMM behavior, albeit with blocking temperatures well below 500 mK even for frequencies as high as 160 kHz. In 3 the onset of ferromagnetism in the bimetallic Mn(II) Cr(III) network is observed at Tc = 5 K. Finally, in the hybrid compound 1 the interaction between the two magnetic networks leads to the antiparallel arrangement of their respective magnetizations, that is, to a ferrimagnetic phase. This coupling induces also important changes on the magnetic properties of 1 with respect to those of the reference compounds 2 and 3. In particular, compound 1 shows a large magnetization hysteresis below 1 K, which is in sharp contrast with the near-reversible magnetizations that the SMMs and the oxalate ferromagnetic lattice show under the same conditions. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Transposon assisted gene insertion technology (TAGIT: a tool for generating fluorescent fusion proteins.

    Directory of Open Access Journals (Sweden)

    James A Gregory

    2010-01-01

    Full Text Available We constructed a transposon (transposon assisted gene insertion technology, or TAGIT that allows the random insertion of gfp (or other genes into chromosomal loci without disrupting operon structure or regulation. TAGIT is a modified Tn5 transposon that uses Kan(R to select for insertions on the chromosome or plasmid, beta-galactosidase to identify in-frame gene fusions, and Cre recombinase to excise the kan and lacZ genes in vivo. The resulting gfp insertions maintain target gene reading frame (to the 5' and 3' of gfp and are integrated at the native chromosomal locus, thereby maintaining native expression signals. Libraries can be screened to identify GFP insertions that maintain target protein function at native expression levels, allowing more trustworthy localization studies. We here use TAGIT to generate a library of GFP insertions in the Escherichia coli lactose repressor (LacI. We identified fully functional GFP insertions and partially functional insertions that bind DNA but fail to repress the lacZ operon. Several of these latter GFP insertions localize to lacO arrays integrated in the E. coli chromosome without producing the elongated cells frequently observed when functional LacI-GFP fusions are used in chromosome tagging experiments. TAGIT thereby faciliates the isolation of fully functional insertions of fluorescent proteins into target proteins expressed from the native chromosomal locus as well as potentially useful partially functional proteins.

  14. QualitySNP: a pipeline for detecting single nucleotide polymorphisms and insertions/deletions in EST data from diploid and polyploid species

    Directory of Open Access Journals (Sweden)

    Voorrips Roeland E

    2006-10-01

    Full Text Available Abstract Background Single nucleotide polymorphisms (SNPs are important tools in studying complex genetic traits and genome evolution. Computational strategies for SNP discovery make use of the large number of sequences present in public databases (in most cases as expressed sequence tags (ESTs and are considered to be faster and more cost-effective than experimental procedures. A major challenge in computational SNP discovery is distinguishing allelic variation from sequence variation between paralogous sequences, in addition to recognizing sequencing errors. For the majority of the public EST sequences, trace or quality files are lacking which makes detection of reliable SNPs even more difficult because it has to rely on sequence comparisons only. Results We have developed a new algorithm to detect reliable SNPs and insertions/deletions (indels in EST data, both with and without quality files. Implemented in a pipeline called QualitySNP, it uses three filters for the identification of reliable SNPs. Filter 1 screens for all potential SNPs and identifies variation between or within genotypes. Filter 2 is the core filter that uses a haplotype-based strategy to detect reliable SNPs. Clusters with potential paralogs as well as false SNPs caused by sequencing errors are identified. Filter 3 screens SNPs by calculating a confidence score, based upon sequence redundancy and quality. Non-synonymous SNPs are subsequently identified by detecting open reading frames of consensus sequences (contigs with SNPs. The pipeline includes a data storage and retrieval system for haplotypes, SNPs and alignments. QualitySNP's versatility is demonstrated by the identification of SNPs in EST datasets from potato, chicken and humans. Conclusion QualitySNP is an efficient tool for SNP detection, storage and retrieval in diploid as well as polyploid species. It is available for running on Linux or UNIX systems. The program, test data, and user manual are available at

  15. Genomic diversity and affinities in population groups of North West India: an analysis of Alu insertion and a single nucleotide polymorphism.

    Science.gov (United States)

    Saini, J S; Kumar, A; Matharoo, K; Sokhi, J; Badaruddoza; Bhanwer, A J S

    2012-12-15

    The North West region of India is extremely important to understand the peopling of India, as it acted as a corridor to the foreign invaders from Eurasia and Central Asia. A series of these invasions along with multiple migrations led to intermixture of variable populations, strongly contributing to genetic variations. The present investigation was designed to explore the genetic diversities and affinities among the five major ethnic groups from North West India; Brahmin, Jat Sikh, Bania, Rajput and Gujjar. A total of 327 individuals of the abovementioned ethnic groups were analyzed for 4 Alu insertion marker loci (ACE, PV92, APO and D1) and a Single Nucleotide Polymorphism (SNP) rs2234693 in the intronic region of the ESR1 gene. Statistical analysis was performed to interpret the genetic structure and diversity of the population groups. Genotypes for ACE, APO, ESR1 and PV92 loci were found to be in Hardy-Weinberg equilibrium in all the ethnic groups, while significant departures were observed at the D1 locus in every investigated population after Bonferroni's correction. The average heterozygosity for all the loci in these ethnic groups was fairly substantial ranging from 0.3927 ± 0.1877 to 0.4333 ± 0.1416. Inbreeding coefficient indicated an overall 10% decrease in heterozygosity in these North West Indian populations. The gene differentiation among the populations was observed to be of the order of 0.013. Genetic distance estimates revealed that Gujjars were close to Banias and Jat Sikhs were close to Rajputs. Overall the study favored the recent division of the populations of North West India into largely endogamous groups. It was observed that the populations of North West India represent a more or less homogenous genetic entity, owing to their common ancestral history as well as geographical proximity. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. QualitySNP: a pipeline for detecting single nucleotide polymorphisms and insertions/deletions in EST data from diploid and polyploid species

    Science.gov (United States)

    Tang, Jifeng; Vosman, Ben; Voorrips, Roeland E; van der Linden, C Gerard; Leunissen, Jack AM

    2006-01-01

    Background Single nucleotide polymorphisms (SNPs) are important tools in studying complex genetic traits and genome evolution. Computational strategies for SNP discovery make use of the large number of sequences present in public databases (in most cases as expressed sequence tags (ESTs)) and are considered to be faster and more cost-effective than experimental procedures. A major challenge in computational SNP discovery is distinguishing allelic variation from sequence variation between paralogous sequences, in addition to recognizing sequencing errors. For the majority of the public EST sequences, trace or quality files are lacking which makes detection of reliable SNPs even more difficult because it has to rely on sequence comparisons only. Results We have developed a new algorithm to detect reliable SNPs and insertions/deletions (indels) in EST data, both with and without quality files. Implemented in a pipeline called QualitySNP, it uses three filters for the identification of reliable SNPs. Filter 1 screens for all potential SNPs and identifies variation between or within genotypes. Filter 2 is the core filter that uses a haplotype-based strategy to detect reliable SNPs. Clusters with potential paralogs as well as false SNPs caused by sequencing errors are identified. Filter 3 screens SNPs by calculating a confidence score, based upon sequence redundancy and quality. Non-synonymous SNPs are subsequently identified by detecting open reading frames of consensus sequences (contigs) with SNPs. The pipeline includes a data storage and retrieval system for haplotypes, SNPs and alignments. QualitySNP's versatility is demonstrated by the identification of SNPs in EST datasets from potato, chicken and humans. Conclusion QualitySNP is an efficient tool for SNP detection, storage and retrieval in diploid as well as polyploid species. It is available for running on Linux or UNIX systems. The program, test data, and user manual are available at and as Additional files

  17. Comparison of conventional straight and swan-neck straight catheters inserted by percutaneous method for continuous ambulatory peritoneal dialysis: a single-center study.

    Science.gov (United States)

    Singh, Shivendra; Prakash, Jai; Singh, R G; Dole, P K; Pant, Pragya

    2015-10-01

    To evaluate the incidence of mechanical and infectious complications of conventional straight catheter (SC) versus swan-neck straight catheter (SNSC) implanted by percutaneous method. We retrospectively analyzed 45 catheter insertions being done by percutaneous method from January 1, 2011, to May 31, 2014. SC was inserted in 24 patients, and SNSC was inserted in 21 patients. Baseline characteristics for the two groups were similar with respect to age, sex and diabetic nephropathy as the cause for end-stage renal disease. Incidence of mechanical and infectious complications in SNSC group was found to be low as compared to the SC group and was statistically significant (1 in 11.6 patient months vs. 1 in 14.4 patient months, p = 0.02). Catheter migration was found to be the most common mechanical complication (20 %), and peritonitis was found to be the most common infectious complication in conventional SC group (27 episodes in 420 patient months vs. 11 episodes in 333 patient months, p = 0.03). The incidence of exit site and tunnel infection rates revealed no difference between the groups. SNSC insertion by percutaneous method is associated with low mechanical and infectious complications.

  18. The optimum bolus dose of remifentanil to facilitate laryngeal mask airway insertion with a single standard dose of propofol at induction in children.

    Science.gov (United States)

    Kwak, H J; Kim, J Y; Kim, Y B; Chae, Y J; Kim, J Y

    2008-09-01

    The purpose of this study was to determine the optimal bolus dose of remifentanil required for the successful insertion of the laryngeal mask airway during propofol induction in children without a neuromuscular blocking agent. Twenty-six paediatric patients, aged 3-10 years, requiring anaesthesia for short ambulatory surgery were recruited. A predetermined bolus dose of remifentanil was injected over 30 s, followed by propofol 2.5 mg.kg(-1) over 10 s. The bolus dose of remifentanil was determined by a modified Dixon's up-and-down method, starting from 0.5 microg.kg(-1) (0.1 microg.kg(-1) as a step size). Laryngeal mask insertion was attempted 90 s after the end of remifentanil injection and the response of patients was classified as either 'movement' or 'no movement'. The bolus dose of remifentanil at which there was a 50% probability of successful laryngeal mask insertion (ED(50)) during induction with 2.5 mg.kg(-1) propofol was 0.56 (0.07) microg.kg(-1) in children without a neuromuscular blocking agent. From probit analysis, the ED(50) and ED(95) of remifentanil were 0.52 microg.kg(-1) (95% confidence limits, 0.42-0.62 microg.kg(-1)) and 0.71 microg.kg(-1) (95% confidence limits, 0.61-1.40 microg.kg(-1)), respectively.

  19. DNA sequence analysis of spontaneous and γ-radiation (anoxic)-induced lacId mutations in Escherichia coli umuC122::Tn5: Differential requirement for umuC at G·C vs. A·T sites and for the production of transversions vs. transitions

    International Nuclear Information System (INIS)

    Sargentini, Neil J.; Smith, Kendric C.

    1994-01-01

    Escherichia coli umuC122::Tn5 cells were γ-irradiated ( 137 Cs, 750 Gy, under N 2 ), and lac-constitutive mutants were produced at 36% of the wild-type level. The specific nature of the umuC strain's partial radiation mutability was determined by sequencing 325 radiation-induced lacI d mutations. The yields of radiation-induced mutation classes in the umuC strain (as a percentage of the wild-type yield) were: 80% for A·T approaches G·C transitions, 70% for multi-base additions, 60% for single-base deletions, 53% for A·T approaches C·G transversions, 36% for G·C approaches A·T transitions, 25% for multi-base deletions, 21% for A·T approaches T·A transversions, 11% for G·C approaches C·G transversions, 9% for G·C approaches T·A transversions, and 0% for multiple mutations. Based on these deficiencies and other factors, it is concluded that the umuC strain is near-normal for A·T approaches G·C transitions, single-base deletions and possibly A·T approaches C·G transversions; is generally deficient for mutagenesis at G·C sites and for transversions, and is grossly deficient in multiple mutations. Damage at G·C sites seems more difficult for translesion DNA synthesis to bypass than damage at A·T sites, and especially when trying to produce a transversion. The yield of G·C approaches A·T transitions in the umuC strain (36% of the wild-type level) argues that abasic sites are involved in no more than 64% of γ-radiation-induced base substitutions in the wild-type strain. Altogether, these data suggest that the UmuC and UmuD' proteins facilitate, rather than being absolutely required for, translesion DNA synthesis; with the degree of facilitation being dependent both on the nature of the non-coding DNA damage, i.e., at G·C vs. A·T sites, and on the nature of the mis-incorporated base, i.e., whether it induces transversions or transitions

  20. Lattice insertions for POPAE

    International Nuclear Information System (INIS)

    Cho, Y.; Crosbie, E.A.; Diebold, R.; Johnson, D.E.; Ohnuma, S.; Ruggiero, A.G.; Teng, L.C.

    1977-01-01

    Four types of insertions are described for the six 200-m straight sections of POPAE. All have dispersion matched to zero. (1) Injection-ejection insertion--This has proper high-β values and phase advances for horizontal injection and vertical ejection. (2) Phase-adjust insertion--The phase advance in this insertion is adjustable over a range of approximately 100 0 . (3) General-purpose insertion--The β* is adjustable from 2.5. to 200 m and the crossing angle is adjustable from 0 to 11 mrad. (4) High-luminosity insertion--This gives an even lower β + of meter

  1. Whole exome sequencing identified a novel single base pair insertion mutation in the EYS gene in a six generation family with retinitis pigmentosa.

    Science.gov (United States)

    Hashmi, Jamil Amjad; Albarry, Maan Abdullah; Almatrafi, Ahmed M; Albalawi, Alia M; Mahmood, Amer; Basit, Sulman

    2018-01-01

    Retinitis pigmentosa (RP) is a group of inherited progressive retinal dystrophies (RD) and is characterized by photoreceptor degeneration. RP is clinically and genetically heterogeneous disorder. More than 70 genes are known and, thus, identification of causative genes and mutations in known genes is challenging. This study was designed to identify the underlying genetic defect in a large extended Saudi family with multiple RP affected members. Fundus photography, Optical Coherence Tomography (OCT) and visual field perimetry were performed for affected individuals. Whole exome sequencing was used to detect the underlying genetic defect in a large family with 12 affected individuals showing autosomal recessive isolated RP. WES data analysis identified a novel insertion mutation in the EYS (eyes shut homolog) gene (c.910_911insT; p.Trp304LeufsTer8). Sanger sequencing validates the variant discovered through exome in all 12 affected individuals and showed that this mutation is segregating with RP phenotype in an autosomal recessive manner in 51 individuals of the family tested here. Our study expands the mutation spectrum of EYS gene in RP patients and extends the body of evidence that supports the importance of EYS gene in eye development. © 2017 Japanese Teratology Society.

  2. Comparison of procedures for immediate reconstruction of large osseous defects resulting from removal of a single tooth to prepare for insertion of an endosseous implant after healing

    NARCIS (Netherlands)

    Raghoebar, G. M.; Slater, J. J. H.; den Hartog, L.; Meijer, H. J. A.; Vissink, A.

    This study evaluated the treatment outcome of immediate reconstruction of 45 large osseous defects resulting from removal of a single tooth with a 1:2 mixture of Bio-Oss(R) and autologous tuberosity bone, and three different procedures for soft tissue closing (Bio-Gide(R) membrane, connective tissue

  3. QualitySNP: a pipeline for detecting single nucleotide polymorphisms and insertions/deletions in EST data from diploid and polyploid species

    NARCIS (Netherlands)

    Tang, J.; Vosman, B.; Voorrips, R.E.; Linden, van der C.G.; Leunissen, J.A.M.

    2006-01-01

    Background - Single nucleotide polymorphisms (SNPs) are important tools in studying complex genetic traits and genome evolution. Computational strategies for SNP discovery make use of the large number of sequences present in public databases (in most cases as expressed sequence tags (ESTs)) and are

  4. A new, lateral, continuous, combined, femoral–sciatic nerve approach via a single skin puncture for postoperative analgesia in intramedullary tibial nail insertion

    Directory of Open Access Journals (Sweden)

    Imbelloni LE

    2013-02-01

    Full Text Available Luiz Eduardo Imbelloni,1,2 Carlos Rava,1,3 Marildo A Gouveia21Faculdade de Medicina Nova Esperança, 2Institute for Regional Anesthesia, 3Complexo Hospitalar de Mangabeira Governador Tarcisio Burity, João Pessoa, BrazilBackground: The prevalence of anterior knee pain following intramedullary tibial nail insertion is high. Continuous peripheral nerve blockade is an alternative method of pain control to opiods. This case illustrates the use of femoral nerve and sciatic nerve peripheral catheters with an elastomeric infusion pump for major intramedullary nailing surgery.Case report: A 36-year-old male with fractures to the left leg bones presented for placement of an intramedullary nail under spinal anesthesia. At the end of the procedure, access to the lateral femoral and sciatic continuous nerve block was achieved by using a stimulator connected to a 110 mm 18G Tuohy needle. Postoperative analgesia was provided with a 40-hour infusion of 0.1% bupivacaine (400 mL at a rate of 10 mL hour-1 with an elastomeric pump. Anesthetic dispersion and contrast were investigated. The analog scale remained with scores below 3 during the 40 hours after surgery, and boluses were not necessary.Conclusion: The use of a femoral and sciatic nerve peripheral catheter offered an alternative to conventional pain control. Continuous femoral–sciatic peripheral blockade via a skin puncture with an infusion of 0.1% bupivacaine with elastomeric pumps is a safe and effective procedure in adults.Keywords: local anesthetic, bupivacaine, continuous peripheral nerve block, orthopedic surgery, tibia, elastomeric pump

  5. Structural characterization of Li1.2 v3o8 insertion electrodes by single-crystal x-ray-diffraction

    CSIR Research Space (South Africa)

    De Picciotto, LA

    1993-08-01

    Full Text Available The crystal structures of Li1.2 V3O8 and a lithiated product Li4.0V3O8 have been determined by single-crystal X-ray diffraction methods. The structure refinement of Li1.2 V308 confirms that of Li1+xV3O8(x almost-equal-to 0) reported by Wadsley thirty...

  6. Single amino acid insertions in extracellular loop 2 of Bombyx mori ABCC2 disrupt its receptor function for Bacillus thuringiensis Cry1Ab and Cry1Ac but not Cry1Aa toxins.

    Science.gov (United States)

    Tanaka, Shiho; Miyamoto, Kazuhisa; Noda, Hiroaki; Endo, Haruka; Kikuta, Shingo; Sato, Ryoichi

    2016-04-01

    In a previous report, seven Cry1Ab-resistant strains were identified in the silkworm, Bombyx mori; these strains were shown to have a tyrosine insertion at position 234 in extracellular loop 2 of the ABC transporter C2 (BmABCC2). This insertion was confirmed to destroy the receptor function of BmABCC2 and confer the strains resistance against Cry1Ab and Cry1Ac. However, these strains were susceptible to Cry1Aa. In this report, we examined the mechanisms of the loss of receptor function of the transporter by expressing mutations in Sf9 cells. After replacement of one or two of the five amino acid residues in loop 2 of the susceptible BmABCC2 gene [BmABCC2_S] with alanine, cells still showed susceptibility, retaining the receptor function. Five mutants with single amino acid insertions at position 234 in BmABCC2 were also generated, resulting in loop 2 having six amino acids, which corresponds to replacing the tyrosine insertion in the resistant BmABCC2 gene [BmABCC2_R(+(234)Y)] with another amino acid. All five mutants exhibited loss of function against Cry1Ab and Cry1Ac. These results suggest that the amino acid sequence in loop 2 is less important than the loop size (five vs. six amino acids) or loop structure for Cry1Ab and Cry1Ac activity. Several domain-swapped mutant toxins were then generated among Cry1Aa, Cry1Ab, and Cry1Ac, which are composed of three domains. Swapped mutants containing domain II of Cry1Ab or Cry1Ac did not kill Sf9 cells expressing BmABCC2_R(+(234)Y), suggesting that domain II of the Cry toxin is related to the interaction with the receptor function of BmABCC2. This also suggests that different reactions against Bt-toxins in some B. mori strains, that is, Cry1Ab resistance or Cry1Aa susceptibility, are attributable to structural differences in domain II of Cry1A toxins. Copyright © 2016. Published by Elsevier Inc.

  7. Tie rod insertion test

    CERN Multimedia

    B. LEVESY

    2002-01-01

    The superconducting coil is inserted in the outer vaccum tank and supported by a set of tie rods. These tie rods are made of titanium alloy. This test reproduce the final insertion of the tie rods inside the outer vacuum tank.

  8. Comparing Leaf and Root Insertion

    Directory of Open Access Journals (Sweden)

    Jaco Geldenhuys

    2010-07-01

    Full Text Available We consider two ways of inserting a key into a binary search tree: leaf insertion which is the standard method, and root insertion which involves additional rotations. Although the respective cost of constructing leaf and root insertion binary search trees trees, in terms of comparisons, are the same in the average case, we show that in the worst case the construction of a root insertion binary search tree needs approximately 50% of the number of comparisons required by leaf insertion.

  9. Insertion site assessment of peripherally inserted central catheters: Inter-observer agreement between nurses and inpatients.

    Science.gov (United States)

    Webster, Joan; Northfield, Sarah; Larsen, Emily N; Marsh, Nicole; Rickard, Claire M; Chan, Raymond J

    2018-03-01

    Many patients are discharged from hospital with a peripherally inserted central catheter in place. Monitoring the peripherally inserted central catheter insertion site for clinical and research purposes is important for identifying complications, but the extent to which patients can reliably report the condition of their catheter insertion site is uncertain. The aim of this study was to assess the inter-observer agreement between nurses and patients when assessing a peripherally inserted central catheter site. The study was based on inpatients who were enrolled in a single-centre, randomised controlled trial comparing four different dressing and securement devices for peripherally inserted central catheter sites. A seven-item peripherally inserted central catheter site assessment tool, containing questions about the condition of the dressing and the insertion site, was developed. Assessment was conducted once by the research nurse and, within a few minutes, independently by the patient. Proportions of agreement and Cohen's kappa were calculated. In total, 73 patients agreed to participate. Overall, percentage agreement ranged from 83% to 100% (kappa = .65-.82). For important clinical signs (redness, swelling, ooze, pus and tracking), there were high levels of percentage agreement (99%-100%). The high level of agreement between nurse/patient pairs make the instrument useful for assessing peripherally inserted central catheter-associated signs of localised infection, allergic or irritant dermatitis or dressing dislodgement in a community setting.

  10. Nanopattern insert molding

    International Nuclear Information System (INIS)

    Kim, S H; Youn, J R; Jeong, J H

    2010-01-01

    A new method was investigated to produce nanopatterns on polymeric surfaces with high resolution, good productivity, and low cost. It has certain advantages when compared with such conventional techniques as nanoimprint lithography (NIL), hot embossing, and injection molding. Polyvinyl alcohol (PVA) was utilized for preparation of the stamp with nanopatterns on its surface. The nanoimprinted PVA film was inserted into the cavity and the polymer melt was injected into the mold. Nanopatterns with pillars smaller than 100 nm were produced on the polymeric surface. The water soluble PVA film was used as the inserted template to overcome the difficulties of releasing the nanopatterned film from the substrate.

  11. Inserting the CMS solenoid

    CERN Multimedia

    Maximilien Brice

    2005-01-01

    The huge superconducting solenoid for CMS is inserted into the cryostat barrel. CMS uses the world's largest thin solenoid, in terms of energy stored, and is 12 m long, with a diameter of 6 m and weighing 220 tonnes. When turned on the magnet will produce a field strength of 4 T using superconducting niobium-titanium material at 4.5 K.

  12. Insertion in Persian

    Science.gov (United States)

    Kambuziya, Aliyeh Kord-e Zafaranlu; Dehghan, Masoud

    2011-01-01

    This paper investigates epenthesis process in Persian to catch some results in relating to vowel and consonant insertion in Persian lexicon. This survey has a close relationship to the description of epenthetic consonants and the conditions in which these consonants are used. Since no word in Persian may begin with a vowel, so that hiatus can't be…

  13. The Composite Insertion Electrode

    DEFF Research Database (Denmark)

    Atlung, Sven; Zachau-Christiansen, Birgit; West, Keld

    1984-01-01

    The specific energy obtainable by discharge of porous insertion electrodes is limited by electrolyte depletion in thepores. This can be overcome using a solid ion conductor as electrolyte. The term "composite" is used to distinguishthese electrodes from porous electrodes with liquid electrolyte...

  14. Transposon insertion libraries for the characterization of mutants from the kiwifruit pathogen Pseudomonas syringae pv. actinidiae

    Science.gov (United States)

    Mesarich, Carl H.; Rees-George, Jonathan; Gardner, Paul P.; Ghomi, Fatemeh Ashari; Gerth, Monica L.; Andersen, Mark T.; Rikkerink, Erik H. A.; Fineran, Peter C.

    2017-01-01

    Pseudomonas syringae pv. actinidiae (Psa), the causal agent of kiwifruit canker, is one of the most devastating plant diseases of recent times. We have generated two mini-Tn5-based random insertion libraries of Psa ICMP 18884. The first, a ‘phenotype of interest’ (POI) library, consists of 10,368 independent mutants gridded into 96-well plates. By replica plating onto selective media, the POI library was successfully screened for auxotrophic and motility mutants. Lipopolysaccharide (LPS) biosynthesis mutants with ‘Fuzzy-Spreader’-like morphologies were also identified through a visual screen. The second, a ‘mutant of interest’ (MOI) library, comprises around 96,000 independent mutants, also stored in 96-well plates, with approximately 200 individuals per well. The MOI library was sequenced on the Illumina MiSeq platform using Transposon-Directed Insertion site Sequencing (TraDIS) to map insertion sites onto the Psa genome. A grid-based PCR method was developed to recover individual mutants, and using this strategy, the MOI library was successfully screened for a putative LPS mutant not identified in the visual screen. The Psa chromosome and plasmid had 24,031 and 1,236 independent insertion events respectively, giving insertion frequencies of 3.65 and 16.6 per kb respectively. These data suggest that the MOI library is near saturation, with the theoretical probability of finding an insert in any one chromosomal gene estimated to be 97.5%. However, only 47% of chromosomal genes had insertions. This surprisingly low rate cannot be solely explained by the lack of insertions in essential genes, which would be expected to be around 5%. Strikingly, many accessory genes, including most of those encoding type III effectors, lacked insertions. In contrast, 94% of genes on the Psa plasmid had insertions, including for example, the type III effector HopAU1. These results suggest that some chromosomal sites are rendered inaccessible to transposon insertion, either

  15. Fuel insert shuffler

    International Nuclear Information System (INIS)

    Naser, J.; Colley, R.; Gaiser, J.; Brookmire, T.; Engle, S.

    1987-01-01

    The potential for the use of expert systems in the nuclear power industry is widely recognized. The benefits of such systems include consistency of reasoning during off-normal situations when humans are under great stress, the reduction of time required to perform certain functions and the retention of human expertise in performing specialized functions. As the potential benefits are more and more demonstrated and realized, the development of expert systems becomes a necessary part of the nuclear power industry. The development of the fuel insert shuffle expert system is used as a case study. In fact, it shows that the potential benefits are realizable. Currently, the development of the insert shuffle plan requires three to four man-weeks of effort. Further modifications to this plan are sometimes required dur to either changes in the desired core load pattern or damaged fuel assemblies or inserts. These changes generally require two to four man-days of effort and could be stressful if they are critical path items on the outage schedule

  16. Fuel assembly insertion system

    International Nuclear Information System (INIS)

    Barkhurst, D.J.

    1987-01-01

    This patent describes a nuclear reactor facility having fuel bundles: a system for the insertion of a fuel bundle into a position where vertically arranged fuel bundles surround and are adjacent the system comprising, in combination, separate and individual centering devices secured to and disposed on top of each fuel bundle adjacent the position. Each such centering device has a generally box-like cap configuration on the upper end of each fuel bundle and includes: a top wall; first and second side walls, each secured along and upper edge to the top wall; a rear plate attached along opposite vertical edges to the first and second side walls; a front inclined wall joined along an upper edge to the top to the wall and attached along opposite vertical edges first and second side walls; pad means secured to the lower edge of the first and second side walls, the front inclined wall and the rear plate for mounting each centering device on top of an associated fuel bundle; pin means carried by at least two of the pad means engageable with an associated aperature for locating and laterally fixing each centering device on top of its respective fuel bundle. Each front inclined wall of each of the centering devices is orientated on top of its respective fuel bundle to slope upwardly and away from the position where upon downward insertion of a fuel bundle any contact between the lower end of the fuel bundle inserted with a front inclined wall of a centering device will laterally deflect the fuel bundle. Each centering device further includes a central socket means secured to the top wall, and an elongated handling pole pivotally attached to the socket

  17. Data Insertion in Bitcoin's Blockchain

    Directory of Open Access Journals (Sweden)

    Andrew Sward

    2018-04-01

    Full Text Available This paper provides the first comprehensive survey of methods for inserting arbitrary data into Bitcoin’s blockchain. Historical methods of data insertion are described, along with lesser-known techniques that are optimized for efficiency. Insertion methods are compared on the basis of efficiency, cost, convenience of data reconstruction, permanence, and potentially negative impact on the Bitcoin ecosystem.

  18. Posterior cruciate ligament's tibial insertions: topographic anatomy and morphometric study

    Directory of Open Access Journals (Sweden)

    Julio Cesar Gali

    2013-06-01

    Full Text Available OBJECTIVE: To provide anatomical and morphometric basis of the posterior cruciate ligament's tibial insertions in order to assist the creation of anatomical tibial tunnels, in the ligament surgical reconstruction. MATERIAL AND METHODS: The topographic anatomy and morphometry of the posterior cruciate ligament's anterolateral and posteromedial bundles' tibial insertions were analyzed in 24 anatomical knee pieces. The pieces were photographed by a digital camera and the images obtained were studied by the software ImageJ, where the bundles' insertion areas were measured in square millimeters, and the length of structures and the distances between significant points were measured in millimeters. RESULTS: In 54.2% of the knees the insertion' shape was concave; in most pieces (41.6% the form of insertion was oval. The average posterior cruciate ligament's tibial insertion total area was 88.33 ± 21.66 mm2; the average anterolateral bundle's tibial insertion area was 46.79 ± 14.10 mm2 and it was 41.54 ± 9.75 mm2 for the posteromedial bundle. CONCLUSIONS: The anterolateral bundle has a tibial insertion area larger than the posteromedial bundle; the insertion areas of those bundles in our study, were smaller than the ones found in the literature. The variations in the posterior cruciate ligament's tibial insertion area suggest that there should be an indication for anatomical reconstructions of this ligament using single or double tibial tunnels according to individual characteristics.

  19. Facility target insert shielding assessment

    Energy Technology Data Exchange (ETDEWEB)

    Mocko, Michal [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-10-06

    Main objective of this report is to assess the basic shielding requirements for the vertical target insert and retrieval port. We used the baseline design for the vertical target insert in our calculations. The insert sits in the 12”-diameter cylindrical shaft extending from the service alley in the top floor of the facility all the way down to the target location. The target retrieval mechanism is a long rod with the target assembly attached and running the entire length of the vertical shaft. The insert also houses the helium cooling supply and return lines each with 2” diameter. In the present study we focused on calculating the neutron and photon dose rate fields on top of the target insert/retrieval mechanism in the service alley. Additionally, we studied a few prototypical configurations of the shielding layers in the vertical insert as well as on the top.

  20. Insertion device and method for accurate and repeatable target insertion

    Energy Technology Data Exchange (ETDEWEB)

    Gubeli, III, Joseph F.; Shinn, Michelle D.; Bevins, Michael E.; Dillon-Townes, Lawrence; Neil, George R.

    2017-07-04

    The present invention discloses a device and a method for inserting and positioning a target within a free electron laser, particle accelerator, or other such device that generates or utilizes a beam of energy or particles. The system includes a three-point registration mechanism that insures angular and translational accuracy and repeatability of positioning upon multiple insertions within the same structure.

  1. Development of a high-efficient transformation system of Bacillus pumilus strain DX01 to facilitate gene isolation via gfp-tagged insertional mutagenesis and visualize bacterial colonization of rice roots.

    Science.gov (United States)

    Shen, Xinqian; Chen, Yunpeng; Liu, Tong; Hu, Xiaolu; Gu, Zhenfang

    2013-09-01

    A Tn5 transposition vector, pMOD-tet-egfp, was constructed and used for the random insertional mutagenesis of Bacillus pumilus. Various parameters were investigated to increase the transformation efficiency B. pumilus DX01 via Tn5 transposition complexes (transposome): bacterial growth phase, type of electroporation buffer, electric field strength, and recovery medium. Transformation efficiency was up to 3 × 10(4) transformants/μg of DNA under the optimized electroporation conditions, and a total of 1,467 gfp-tagged transformants were obtained. Fluorescence-activated cell sorting analysis showed that all gfp-tagged bacterial cells expressed GFP, indicating that foreign DNA has been successfully integrated into the genome of B. pumilus and expressed. Finally, flanking DNA sequences were isolated from several transformants and colonization of rice roots by B. pumilus DX01 was also studied. The method developed here will be useful for creating an insertion mutant library of gram-positive bacteria, thus facilitating their molecular genetic and cytological studies.

  2. ISR Superconducting High luminosity Insertion

    CERN Multimedia

    1981-01-01

    The picture shows two of the eight superconducting quadrupoles of the low-beta insertion at intersection I8.The increase of luminosity produced by this insertion was above a factor 7. At right one can also see the Open- Axial- Field Magnet. The person is Stephan Pichler. See also 7702690X, 8102123, 8010397, 8008332.

  3. Lithium insertion in nanostructured titanates

    NARCIS (Netherlands)

    Borghols, W.J.H.

    2010-01-01

    Upon nano-sizing of insertion compounds several significant changes in Li-insertion behavior have been observed for sizes below approximately 50 nm. Although the origins of the phenomena are interrelated, the changes can be divided in three main observations. (1) The formation of new phases, leading

  4. Mechanistic insights on acrylate insertion polymerization.

    Science.gov (United States)

    Guironnet, Damien; Caporaso, Lucia; Neuwald, Boris; Göttker-Schnetmann, Inigo; Cavallo, Luigi; Mecking, Stefan

    2010-03-31

    Complexes [{(PwedgeO)PdMe}(n)] (1(n); PwedgeO = kappa(2)-P,O-Ar(2)PC(6)H(4)SO(2)O with Ar = 2-MeOC(6)H(4)) are a single-component precursor of the (PwedgeO)PdMe fragment devoid of additional coordinating ligands, which also promotes the catalytic oligomerization of acrylates. Exposure of 1(n) to methyl acrylate afforded the two diastereomeric chelate complexes [(PwedgeO)Pd{kappa(2)-C,O-CH(C(O)OMe)CH(2)CH(C(O)OMe)CH(2)CH(3)}] (3-meso and 3-rac) resulting from two consecutive 2,1-insertions of methyl acrylate into the Pd-Me bond with the same or opposite stereochemistry, respectively, in a 3:2 ratio as demonstrated by comprehensive NMR spectroscopic studies and single crystal X-ray diffraction. These six-membered chelate complexes are direct key models for intermediates of acrylate insertion polymerization, and also ethylene-acrylate copolymerization to high acrylate content copolymers. Studies of the binding of various substrates (pyridine, dmso, ethylene and methyl acrylate) to 3-meso and 3-rac show that hindered displacement of the chelating carbonyl moiety by pi-coordination of incoming monomer significantly retards, but does not prohibit, polymerization. For 3-meso,3-rac + C(2)H(4) right arrow over left arrow 3-meso-C(2)H(4,) 3-rac-C(2)H(4) an equilibrium constant K(353 K) approximately 2 x 10(-3) L mol(-1) was estimated. Reaction of 3-meso, 3-rac with methyl acrylate afforded higher insertion products [(PwedgeO)Pd(C(4)H(6)O(2))(n)Me] (n = 3, 4) as observed by electrospray ionization mass spectrometry (ESI-MS). Theoretical studies by DFT methods of consecutive acrylate insertion provide relative energies of intermediates and transition states, which are consistent with the aforementioned experimental observations, and give detailed insights to the pathways of multiple consecutive acrylate insertions. Acrylate insertion into 3-meso,3-rac is associated with an overall energy barrier of ca. 100 kJ mol(-1).

  5. Percutaneously inserted central catheter - infants

    Science.gov (United States)

    PICC - infants; PQC - infants; Pic line - infants; Per-Q cath - infants ... A percutaneously inserted central catheter (PICC) is a long, very thin, soft plastic tube that is put into a small blood vessel. This article addresses PICCs in ...

  6. Non-insertional Achilles tendinopathy

    Science.gov (United States)

    Pearce, Christopher J.; Tan, Audrey

    2016-01-01

    Non-insertional Achilles tendinopathy is a degenerative condition characterised by pain on activity. Eccentric stretching is the most effective treatment. Surgical treatment is reserved for recalcitrant cases. Minimally-invasive and tendinoscopic treatments are showing promising results. Cite this article: Pearce CJ, Tan A. Non-insertional Achilles tendinopathy. EFORT Open Rev 2016;1:383-390. DOI: 10.1302/2058-5241.1.160024. PMID:28461917

  7. Detecting deletions, insertions, and single nucleotide substitutions in cloned β-globin genes and new polymorphic nucleotide substitutions in β-globin genes in a Japanese population using ribonuclease cleavage at mismatches in RNA: DNA duplexes

    International Nuclear Information System (INIS)

    Hiyama, Keiko; Kodaira, Mieko; Satoh, Chiyoko.

    1990-08-01

    The applicability of ribonuclease (RNase) cleavage at mismatches in RNA:DNA duplexes (the RNase cleavage method) for determining nucleotide variant rates was examined in a Japanese population. DNA segments of various lengths obtained from four different regions of one normal and three thalassemic cloned human β-globin genes were inserted into transcription vectors. Sense and antisense RNA probes uniformly labeled with 32 P were prepared. When RNA probes of 771 nucleotides (nt) or less were hybridized with cloned DNAs and the resulting duplexes were treated with a mixture of RNases A and T1, the length of products agreed with theoretical values. Twelve possible mismatches were examined. Since both sense and antisense probes were used, uncleavable mismatches such as G:T and G:G which were made from one combination of RNA and DNA strands could be converted to the cleavable C:A and C:C mismatches, respectively, by using the opposite combination. Deletions and insertions of one (G), four(TTCT), five (ATTTT), and 10 (ATTTTATTTT) nt were easily detected. A polymorphic substitution of T to C at position 666 of the second intervening sequence (IVS2-666) of the β-globin gene was detected using genomic DNAs from cell lines established from the peripheral B lymphocytes of 59 unrelated Japanese from Hiroshima or those amplified by polymerase chain reaction (PCR). The frequency of the gene with C at the IVS2-666 (allele C) was 0.48 and that of the gene with T (allene T) was 0.52. Two new polymorphic substitutions of C to A and A to T were detected at nucleotide positions 1789 and 1945 from the capping site, respectively, using genomic DNAs amplified by PCR. We conclude that it would be feasible to use the RNase cleavage method combined with PCR for large-scale screening of variation in chromosomal DNA. (J.P.N.)

  8. [Intracavitary electrocardiogram during the insertion of peripherally inserted central catheters].

    Science.gov (United States)

    Ortiz-Miluy, Gloria; Sánchez-Guerra, Carmen

    2013-01-01

    To evaluate the applicability, feasibility and accuracy of the IC-ECG with column of saline technique for verifying the final tip position of peripherally inserted central catheters (PICC) by specialist nurses. A total of 99 consecutive PICC were inserted. Patients with no superficial ECG P wave, atrial fibrillation, or a pacemaker were excluded. The IC-ECG technique was performed on 84 patients. A chest x-ray was performed after insertion in all cases, in order to compare images with IC-ECG. The technique showed an applicability of 84.4%, an feasibility of 88%, and an accuracy of 87.8%. The IC-ECG technique for verification of catheter PICC tip locations with column of saline is easy to apply, is cost-effective, is achievable by nurses, and does not involve any risk for patients. The technique involves a learning curve, and it must be performed by qualified health care professionals. The technique is performed during the insertion of the catheter, so verification of the tip is made in situ. It reduces future re-insertions due to wrong positioning of the tip. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  9. Increased risk of symptomatic upper-extremity venous thrombosis with multiple peripherally inserted central catheter insertions in pediatric patients.

    Science.gov (United States)

    Gnannt, Ralph; Waespe, Nicolas; Temple, Michael; Amirabadi, Afsaneh; Liu, Kuan; Brandão, Leonardo R; Connolly, Bairbre L

    2018-02-27

    Peripherally inserted central catheters (PICCs) are associated with superficial and deep venous thrombosis of the arm. The purpose of this study was to analyze the sequelae of repeated upper limb PICC insertions in children, in terms of the frequency of upper limb thrombosis in this patient group. The study population included all children who underwent their first successful arm PICC insertion between January 2010 and December 2015. We included subsequent ipsilateral arm PICCs in the analysis. Patients were followed until March 2016 or until any alternative central venous line insertion. For each PICC insertion, we collected demographic variables and line characteristics. We correlated all symptomatic deep and superficial thromboses of the arm with the PICC database. Applying inclusion and exclusion criteria, 2,180 PICCs remained for analysis. We identified first, second, third and fourth PICC insertions in the same arm in 1,955, 181, 38 and 6 patients, respectively. In total there were 57 upper body deep symptomatic thrombotic events. An increasing odds ratio was seen with higher numbers of PICC insertions, which was significant when comparing the first with the third and fourth PICC insertions in the same arm (odds ratio [OR] 6.00, 95% confidence interval [CI] 2.25-16.04, P=0.0004). Double-lumen PICCs were associated with a significantly higher risk of thrombosis than single lumen (OR 2.77, 95% CI 1.72-4.47, P=0.0003). Repetitive PICC insertions in the same arm are associated with an increased risk of symptomatic thrombosis. Double-lumen PICCs are associated with a higher risk of thrombosis compared to single-lumen lines.

  10. Gene Insertion Patterns and Sites

    Science.gov (United States)

    Vain, Philippe; Thole, Vera

    During the past 25 years, the molecular analysis of transgene insertion patterns and sites in plants has greatly contributed to our understanding of the mechanisms underlying transgene integration, expression, and stability in the nuclear genome. Molecular characterization is also an essential step in the safety assessment of genetically modified crops. This chapter describes the standard experimental procedures used to analyze transgene insertion patterns and loci in cereals and grasses transformed using Agrobacterium tumefaciens or direct transfer of DNA. Methods and protocols enabling the determination of the number and configuration of transgenic loci via a combination of inheritance studies, polymerase chain reaction, and Southern analyses are presented. The complete characterization of transgenic inserts in plants is, however, a holistic process relying on a wide variety of experimental approaches. In this chapter, these additional approaches are not detailed but references to relevant bibliographic records are provided.

  11. Fireplace insert and its parameters depend on the used glazing

    Science.gov (United States)

    Papučík, Štefan; Čaja, Alexander

    2016-06-01

    The contribution deals with the analysis of the impact of using double glass to change the performance and emission parameters of the fireplace insert. Conventional fireplace inserts are equipped with heat-resistant glass, which is resistant to high temperatures. For this type of inserts are required to be radiant constituent maximized. Prevailing part of heat is into the interior gets just by radiation through the glazed part. The hot water fireplace inserts is the requirement that the radiant constituent to the environment to a minimum. Therefore, instead of a single glass using double glazing which is intended to reduce this part of heat transfer. The temperature in the furnace is increased, and transmitted most of the heat into the water.

  12. LOFT voltage insertion calibaration program

    International Nuclear Information System (INIS)

    Tillitt, D.N.; Miyasaki, F.S.

    1975-08-01

    The Loss-of-Fluid Test (LOFT) Facility is an experimental facility built around a ''scaled'' version of a large pressurized water reactor (LPWR). Part of this facility is the Data Acquisition and Visual Display System (DAVDS) as defined by the LOFT System Design Document SDD 1.4.2C. The DAVDS has a 702 data channel recording capability of which 548 are recorded digitally. The DAVDS also contains a Voltage Insertion Calibration Subsystem used to inject precise and known voltage steps into the recording systems. The computer program that controls the Voltage Insertion Calibration Subsystem is presented. 7 references. (auth)

  13. Concepts for stereoselective acrylate insertion

    KAUST Repository

    Neuwald, Boris

    2013-01-23

    Various phosphinesulfonato ligands and the corresponding palladium complexes [{((PaO)PdMeCl)-μ-M}n] ([{( X1-Cl)-μ-M}n], (PaO) = κ2- P,O-Ar2PC6H4SO2O) with symmetric (Ar = 2-MeOC6H4, 2-CF3C6H4, 2,6-(MeO)2C6H3, 2,6-(iPrO)2C 6H3, 2-(2′,6′-(MeO)2C 6H3)C6H4) and asymmetric substituted phosphorus atoms (Ar1 = 2,6-(MeO)2C6H 3, Ar2 = 2′-(2,6-(MeO)2C 6H3)C6H4; Ar1 = 2,6-(MeO)2C6H3, Ar2 = 2-cHexOC 6H4) were synthesized. Analyses of molecular motions and dynamics by variable temperature NMR studies and line shape analysis were performed for the free ligands and the complexes. The highest barriers of ΔGa = 44-64 kJ/mol were assigned to an aryl rotation process, and the flexibility of the ligand framework was found to be a key obstacle to a more effective stereocontrol. An increase of steric bulk at the aryl substituents raises the motional barriers but diminishes insertion rates and regioselectivity. The stereoselectivity of the first and the second methyl acrylate (MA) insertion into the Pd-Me bond of in situ generated complexes X1 was investigated by NMR and DFT methods. The substitution pattern of the ligand clearly affects the first MA insertion, resulting in a stereoselectivity of up to 6:1 for complexes with an asymmetric substituted phosphorus. In the consecutive insertion, the stereoselectivity is diminished in all cases. DFT analysis of the corresponding insertion transition states revealed that a selectivity for the first insertion with asymmetric (P aO) complexes is diminished in the consecutive insertions due to uncooperatively working enantiomorphic and chain end stereocontrol. From these observations, further concepts are developed. © 2012 American Chemical Society.

  14. Lithium Insertion In Silicon Nanowires: An ab Initio Study

    KAUST Repository

    Zhang, Qianfan

    2010-09-08

    The ultrahigh specific lithium ion storage capacity of Si nanowires (SiNWs) has been demonstrated recently and has opened up exciting opportunities for energy storage. However, a systematic theoretical study on lithium insertion in SiNWs remains a challenge, and as a result, understanding of the fundamental interaction and microscopic dynamics during lithium insertion is still lacking. This paper focuses on the study of single Li atom insertion into SiNWs with different sizes and axis orientations by using full ab initio calculations. We show that the binding energy of interstitial Li increases as the SiNW diameter grows. The binding energies at different insertion sites, which can be classified as surface, intermediate, and core sites, are quite different. We find that surface sites are energetically the most favorable insertion positions and that intermediate sites are the most unfavorable insertion positions. Compared with the other growth directions, the [110] SiNWs with different diameters always present the highest binding energies on various insertion locations, which indicates that [110] SiNWs are more favorable by Li doping. Furthermore, we study Li diffusion inside SiNWs. The results show that the Li surface diffusion has a much higher chance to occur than the surface to core diffusion, which is consistent with the experimental observation that the Li insertion in SiNWs is layer by layer from surface to inner region. After overcoming a large barrier crossing surface-to-intermediate region, the diffusion toward center has a higher possibility to occur than the inverse process. © 2010 American Chemical Society.

  15. The first LHC insertion quadrupole

    CERN Document Server

    2004-01-01

    An important milestone was reached in December 2003 at the CERN Magnet Assembly Facility. The team from the Accelerator Technology - Magnet and Electrical Systems group, AT-MEL, completed the first special superconducting quadrupole for the LHC insertions which house the experiments and major collider systems. The magnet is 8 metres long and contains two matching quadrupole magnets and an orbit corrector, a dipole magnet, used to correct errors in quadrupole alignment. All were tested in liquid helium and reached the ultimate performance criteria required for the LHC. After insertion in the cryostat, the superconducting magnet will be installed as the Q9 quadrupole in sector 7-8, the first sector of the LHC to be put in place in 2004. Members of the quadrupole team, from the AT-MEL group, gathered around the Q9 quadrupole at its inauguration on 12 December 2003 in building 181.

  16. ATLAS insertable B-layer

    Czech Academy of Sciences Publication Activity Database

    Marčišovský, Michal

    2011-01-01

    Roč. 633, č. 1 (2011), "S224"-"S225" ISSN 0168-9002. [International workshop on radiation imaging detectors /11./. Praha, 26.06.2009-02.07.2009] R&D Projects: GA MŠk LA08015; GA MŠk LA08032 Institutional research plan: CEZ:AV0Z10100502 Keywords : ATLAS * pixel detector * insertable B-layer Subject RIV: BF - Elementary Particles and High Energy Physics Impact factor: 1.207, year: 2011

  17. Inserting Agility in System Development

    Science.gov (United States)

    2012-07-01

    Agile IT Acquisition, IT Box, Scrum Inserting Agility in System Development Matthew R. Kennedy and Lt Col Dan Ward, USAF With the fast-paced nature... Scrum is a process to manage a product, eXtreme Program- ming (XP) is an agile development methodology focused on software development as a whole. XP...249 A Publication of the Defense Acquisition University http://www.dau.mil Keywords: Agile , Systems Engineering, Information Technology (IT), DoD

  18. Ring insertions as light sources

    International Nuclear Information System (INIS)

    Green, G.K.

    1975-01-01

    Bending magnets can be inserted in the long straight sections of electron storage rings to produce synchrotron radiation. If the design is carefully proportioned, the bending magnets create only a small perturbation of the properties of the ring. The resulting spectra have favorable optical properties as sources for spectroscopy and diffraction studies. The characteristics of the source are discussed, and the geometrical requirements of the magnets are presented

  19. HTS Insert Magnet Design Study

    CERN Document Server

    Devaux, M; Fleiter, J; Fazilleau, P; Lécrevisse, T; Pes, C; Rey, J-M; Rifflet, J-M; Sorbi, M; Stenvall, A; Tixador, P; Volpini, G

    2011-01-01

    Future accelerator magnets will need to reach higher field in the range of 20 T. This field level is very difficult to reach using only Low Temperature Superconductor materials whereas High Temperature Superconductors (HTS) provide interesting opportunities. High current densities and stress levels are needed to design such magnets. YBCO superconductor indeed carries large current densities under high magnetic field and provides good mechanical properties especially when produced using the IBAD approach. The HFM EUCARD program studies the design and the realization of an HTS insert of 6 T inside a Nb3Sn dipole of 13T at 4.2 K. In the2HTS insert, engineering current densities higher than 250 MA/m under 19 T are required to fulfill the specifications. The stress level is also very severe. YBCO IBAD tapes theoretically meet these challenges from presented measurements. The insert protection is also a critical because HTS materials show low quench propagation velocities and the coupling with the Nb3Sn magnet make...

  20. Mechanistic studies of ionizing radiation and oxidative mutagenesis: Genetic effects of a single 8-hydroxyguanine (7-hydro-8-oxoguanine) residue inserted at a unique site in a viral genome

    Energy Technology Data Exchange (ETDEWEB)

    Wood, M.L.; Essigmann, J.M. (Massachusetts Institute of Technology, Cambridge (USA)); Dizdaroglu, M.; Gajewski, E. (National Institute of Standards and Technology, Gaithersburg, MD (USA))

    1990-07-31

    T4 RNA ligase was used to construct a deoxypentanucleotide containing a single 8-hydroxyguanine (7-hydro-8-oxoguanine; G{sup 8-OH}) residue, which is one of the putatively mutagenic DNA adducts produced by oxidants and ionizing radiation. The pentamer d(GCTAG{sup 8-OH})p was prepared by the ligation of a chemically synthesized acceptor molecule, d(GCTA), to an adducted donor, 8-hydroxy-2{prime}-deoxyguanosine 5{prime},3{prime}-bisphosphate. Following 3{prime}-dephosphorylation, the pentamer was characterized by UV spectroscopy, by high-pressure liquid chromatography, and by gas chromatography-mass spectrometry of the nucleosides released by enzymatic hydrolysis. Both d(GCTAG{sup 8-OH}) and an unmodified control were 5{prime}-phosphorylated by using ({gamma}-{sup 32}P)ATP and incorporated covalently by DNA ligase into a five-base gap at a unique NheI restriction site in the otherwise duplex genome of an M13mp19 derivative. The adduct was part of a nonsense codon in a unique restriction site in order to facilitate the identification and selection of mutants generated by the replication of the modified genome in Escherichia coli. Both control and adducted pentamers ligated into the genome at 50% of the maximum theoretical efficiency, and nearly all of the site-specifically adducted products possessed pentanucleotides that were covalently linked at both 5{prime} and 3{prime} termini. Transformation of E. coli strain DL7 with the uniquely modified single-stranded genome resulted in {approximately}0.5-1.0% of the progeny phase showing the G {yields} T transversion mutation at the original position of G{sup 8-OH}. The vector containing G{sup 8-OH} also transformed 50-90% as efficiently as the unmodified control, indicating that the adduct can be both weakly cytotoxic and mutagenic to the phase genome.

  1. High Lithium Insertion Voltage Single-Crystal H2 Ti12 O25 Nanorods as a High-Capacity and High-Rate Lithium-Ion Battery Anode Material.

    Science.gov (United States)

    Guo, Qiang; Chen, Li; Shan, Zizhao; Lee, Wee Siang Vincent; Xiao, Wen; Liu, Zhifang; Liang, Jingjing; Yang, Gaoli; Xue, Junmin

    2018-01-10

    H 2 Ti 12 O 25 holds great promise as a high-voltage anode material for advanced lithium-ion battery applications. To enhance its electrochemical performance, control of the crystal orientation and morphology is an effective way to cope with slow Li + -ion diffusion inside H 2 Ti 12 O 25 with severe anisotropy. In this report, Na 2 Ti 6 O 13 nanorods, prepared from Na 2 CO 3 and anatase TiO 2 in molten NaCl medium, were used as a precursor in the synthesis of long single-crystal H 2 Ti 12 O 25 nanorods with reactive facets. The as-prepared H 2 Ti 12 O 25 nanorods with a diameter of 100-200 nm showed higher charge (extraction) specific capacity and better rate performance than previously reported systems. The reversible capacity of H 2 Ti 12 O 25 was 219.8 mAh g -1 at 1C after 100 cycles, 172.1 mAh g -1 at 10C, and 144.4 mAh g -1 at 20C after 200 cycles; these values are higher than those of H 2 Ti 12 O 25 prepared by the conventional soft-chemical method. Moreover, the as-prepared H 2 Ti 12 O 25 nanorods exhibited superior cycle stability with more than 94 % retention of capacity with nearly 100 % coulombic efficiency after 100 cycles at 1C. On the basis of the above results, long single-crystal H 2 Ti 12 O 25 nanorods synthesized in molten NaCl with outstanding electrochemical characteristics hold a significant amount of promise for hybrid electric vehicles and energy-storage systems. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Direct Synthesis of Telechelic Polyethylene by Selective Insertion Polymerization

    KAUST Repository

    Jian, Zhongbao

    2016-10-14

    A single-step route to telechelic polyethylene (PE) is enabled by selective insertion polymerization. PdII-catalyzed copolymerization of ethylene and 2-vinylfuran (VF) generates α,ω-di-furan telechelic polyethylene. Orthogonally reactive exclusively in-chain anhydride groups are formed by terpolymerization with carbic anhydride. Combined experimental and theoretical DFT studies reveal the key for this direct approach to telechelics to be a match of the comonomers’ different electronics and bulk. Identified essential features of the comonomer are that it is an electron-rich olefin that forms an insertion product stabilized by an additional interaction, namely a π–η3 interaction for the case of VF.

  3. Regional insertion: an emergent approach

    International Nuclear Information System (INIS)

    Serra, M.T.F.; Nascimento Teixeira, P. do

    1989-01-01

    The Brazilian Electrical Sector incorporates new variables that expressing the extensive spectrum of environmental impacts in the take of decisions, referring to the viability of realizing a electrical undertaking, attends the several restrictions that are important by the sector and by the society in the environment area and promotes the adequate generation of liquid benefits, consequential of the electrical undertaking. Due to these factors, the Electrical Sector is improving the concept of regional insertion, with the sectorial expansion in long-dated and the created demand in the environmental and social area, focalizing the solution for these questions. (C.G.C.). 1 fig, 2 tabs

  4. Single frequency intracavity SRO

    DEFF Research Database (Denmark)

    Abitan, Haim; Buchhave, Preben

    2000-01-01

    Summary form only given. A single resonance optical parametric oscillator (SRO) is inserted intracavity to a CW high power, single frequency, and ring Nd:YVO4 laser. We obtain a stable single frequency CW SRO with output at 1.7-1.9 μm (idler) and a resonating signal at 2.3-2.6 μm. The behavior...

  5. High aspect ratio catalytic reactor and catalyst inserts therefor

    Science.gov (United States)

    Lin, Jiefeng; Kelly, Sean M.

    2018-04-10

    The present invention relates to high efficient tubular catalytic steam reforming reactor configured from about 0.2 inch to about 2 inch inside diameter high temperature metal alloy tube or pipe and loaded with a plurality of rolled catalyst inserts comprising metallic monoliths. The catalyst insert substrate is formed from a single metal foil without a central supporting structure in the form of a spiral monolith. The single metal foil is treated to have 3-dimensional surface features that provide mechanical support and establish open gas channels between each of the rolled layers. This unique geometry accelerates gas mixing and heat transfer and provides a high catalytic active surface area. The small diameter, high aspect ratio tubular catalytic steam reforming reactors loaded with rolled catalyst inserts can be arranged in a multi-pass non-vertical parallel configuration thermally coupled with a heat source to carry out steam reforming of hydrocarbon-containing feeds. The rolled catalyst inserts are self-supported on the reactor wall and enable efficient heat transfer from the reactor wall to the reactor interior, and lower pressure drop than known particulate catalysts. The heat source can be oxygen transport membrane reactors.

  6. Patterns of transposable element expression and insertion in cancer

    Directory of Open Access Journals (Sweden)

    Evan A Clayton

    2016-11-01

    Full Text Available Human transposable element (TE activity in somatic tissues causes mutations that can contribute to tumorigenesis. Indeed, TE insertion mutations have been implicated in the etiology of a number of different cancer types. Nevertheless, the full extent of somatic TE activity, along with its relationship to tumorigenesis, have yet to be fully explored. Recent developments in bioinformatics software make it possible to analyze TE expression levels and TE insertional activity directly from transcriptome (RNA-seq and whole genome (DNA-seq next-generation sequence data. We applied these new sequence analysis techniques to matched normal and primary tumor patient samples from the Cancer Genome Atlas (TCGA in order to analyze the patterns of TE expression and insertion for three cancer types: breast invasive carcinoma, head and neck squamous cell carcinoma, and lung adenocarcinoma. Our analysis focused on the three most abundant families of active human TEs: Alu, SVA and L1. We found evidence for high levels of somatic TE activity for these three families in normal and cancer samples across diverse tissue types. Abundant transcripts for all three TE families were detected in both normal and cancer tissues along with an average of ~80 unique TE insertions per individual patient/tissue. We observed an increase in L1 transcript expression and L1 insertional activity in primary tumor samples for all three cancer types. Tumor-specific TE insertions are enriched for private mutations, consistent with a potentially causal role in tumorigenesis. We used genome feature analysis to investigate two specific cases of putative cancer-causing TE mutations in further detail. An Alu insertion in an upstream enhancer of the CBL tumor suppressor gene is associated with down-regulation of the gene in a single breast cancer patient, and an L1 insertion in the first exon of the BAALC gene also disrupts its expression in head and neck squamous cell carcinoma. Our results are

  7. Neuropathy associated with etonogestrel implant insertion.

    Science.gov (United States)

    Brown, Matthew; Britton, John

    2012-11-01

    The etonogestrel contraceptive implant (Implanon®) is an effective, long-acting subdermal method of hormonal contraception for women. We describe a case of forearm pain and hypoesthesia associated with the insertion of the Implanon® contraceptive implant in a healthy 26-year-old female. These symptoms were due to direct implant contact with the medial cutaneous nerve of the forearm. The importance of correct insertion technique is discussed. Care should be taken to avoid nerve injury during insertion of subdermal contraceptive implants. An understanding of regional anatomy and the correct insertion technique will prevent insertion-related complications. Nexplanon® has been developed to replace Implanon®. It has a redesigned applicator intended to increase insertion accuracy. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. Hamstring tendons insertion - an anatomical study

    OpenAIRE

    Cristiano Antonio Grassi; Vagner Messias Fruheling; Joao Caetano Abdo; Marcio Fernando Aparecido de Moura; Mario Namba; Joao Luiz Vieira da Silva; Luiz Antonio Munhoz da Cunha; Ana Paula Gebert de Oliveira Franco; Isabel Ziesemer Costa; Edmar Stieven Filho

    2013-01-01

    OBJECTIVE: To study the anatomy of the hamstring tendons insertion and anatomical rela-tionships. METHODS: Ten cadaver knees with medial and anterior intact structures were selected. The dissection was performed from anteromedial access to exposure of the insertion of the flexor tendons (FT), tibial plateau (TP) and tibial tuberosity (TT). A needle of 40 × 12 and a caliper were used to measure the distance of the tibial plateau of the knee flexor tendons insertion at 15 mm from the ...

  9. Insertion devices at the advanced photon source

    International Nuclear Information System (INIS)

    Moog, E.R.

    1996-01-01

    The insertion devices being installed at the Advanced Photon Source cause the stored particle beam to wiggle, emitting x-rays with each wiggle. These x-rays combine to make an intense beam of radiation. Both wiggler and undulator types of insertion devices are being installed; the characteristics of the radiation produced by these two types of insertion devices are discussed, along with the reasons for those characteristics

  10. Folding and insertion thermodynamics of the transmembrane WALP peptide.

    Science.gov (United States)

    Bereau, Tristan; Bennett, W F Drew; Pfaendtner, Jim; Deserno, Markus; Karttunen, Mikko

    2015-12-28

    The anchor of most integral membrane proteins consists of one or several helices spanning the lipid bilayer. The WALP peptide, GWW(LA)n (L)WWA, is a common model helix to study the fundamentals of protein insertion and folding, as well as helix-helix association in the membrane. Its structural properties have been illuminated in a large number of experimental and simulation studies. In this combined coarse-grained and atomistic simulation study, we probe the thermodynamics of a single WALP peptide, focusing on both the insertion across the water-membrane interface, as well as folding in both water and a membrane. The potential of mean force characterizing the peptide's insertion into the membrane shows qualitatively similar behavior across peptides and three force fields. However, the Martini force field exhibits a pronounced secondary minimum for an adsorbed interfacial state, which may even become the global minimum-in contrast to both atomistic simulations and the alternative PLUM force field. Even though the two coarse-grained models reproduce the free energy of insertion of individual amino acids side chains, they both underestimate its corresponding value for the full peptide (as compared with atomistic simulations), hinting at cooperative physics beyond the residue level. Folding of WALP in the two environments indicates the helix as the most stable structure, though with different relative stabilities and chain-length dependence.

  11. Marginal adaptation of ceramic inserts after cementation

    NARCIS (Netherlands)

    Ozcan, M; Pfeiffer, P; Nergiz, [No Value

    2002-01-01

    The advantage of using ceramic inserts is to prevent major drawbacks of composite resins such as polymerization shrinkage, wear and microleakage. This in vitro study evaluated the marginal adaptation of two approximal ceramic insert systems after cementation to the cavities opened with ultrasonic

  12. Development of Helios target insertion mechanism

    International Nuclear Information System (INIS)

    Day, R.D.; Cummings, C.E.; Tucker, H.E.

    1979-01-01

    A system for precisely positioning a DT-filled target in the Helios target vacuum chamber is described. The target insertion mechanism (TIM), which is designed to insert either a target or a surrogate sphere into the vacuum chamber through an airlock to prevent loss of vacuum, is discussed in detail and its performance is evaluated

  13. Rapid construction of metabolite biosensors using domain-insertion profiling

    Science.gov (United States)

    Nadler, Dana C.; Morgan, Stacy-Anne; Flamholz, Avi; Kortright, Kaitlyn E.; Savage, David F.

    2016-01-01

    Single-fluorescent protein biosensors (SFPBs) are an important class of probes that enable the single-cell quantification of analytes in vivo. Despite advantages over other detection technologies, their use has been limited by the inherent challenges of their construction. Specifically, the rational design of green fluorescent protein (GFP) insertion into a ligand-binding domain, generating the requisite allosteric coupling, remains a rate-limiting step. Here, we describe an unbiased approach, termed domain-insertion profiling with DNA sequencing (DIP-seq), that combines the rapid creation of diverse libraries of potential SFPBs and high-throughput activity assays to identify functional biosensors. As a proof of concept, we construct an SFPB for the important regulatory sugar trehalose. DIP-seq analysis of a trehalose-binding-protein reveals allosteric hotspots for GFP insertion and results in high-dynamic range biosensors that function robustly in vivo. Taken together, DIP-seq simultaneously accelerates metabolite biosensor construction and provides a novel tool for interrogating protein allostery. PMID:27470466

  14. Central Solenoid Insert Technical Specification

    Energy Technology Data Exchange (ETDEWEB)

    Martovetsky, Nicolai N [ORNL; Smirnov, Alexandre [ORNL

    2011-09-01

    The US ITER Project Office (USIPO) is responsible for the ITER central solenoid (CS) contribution to the ITER project. The Central Solenoid Insert (CSI) project will allow ITER validation the appropriate lengths of the conductors to be used in the full-scale CS coils under relevant conditions. The ITER Program plans to build and test a CSI to verify the performance of the CS conductor. The CSI is a one-layer solenoid with an inner diameter of 1.48 m and a height of 4.45 m between electric terminal ends. The coil weight with the terminals is approximately 820 kg without insulation. The major goal of the CSI is to measure the temperature margin of the CS under the ITER direct current (DC) operating conditions, including determining sensitivity to load cycles. Performance of the joints, ramp rate sensitivity, and stability against thermal or electromagnetic disturbances, electrical insulation, losses, and instrumentation are addressed separately and therefore are not major goals in this project. However, losses and joint performance will be tested during the CSI testing campaign. The USIPO will build the CSI that will be tested at the Central Solenoid Model Coil (CSMC) Test Facility at the Japan Atomic Energy Agency (JAEA), Naka, Japan. The industrial vendors (the Suppliers) will report to the USIPO (the Company). All approvals to proceed will be issued by the Company, which in some cases, as specified in this document, will also require the approval of the ITER Organization. Responsibilities and obligations will be covered by respective contracts between the USIPO, called Company interchangeably, and the industrial Prime Contractors, called Suppliers. Different stages of work may be performed by more than one Prime Contractor, as described in this specification. Technical requirements of the contract between the Company and the Prime Contractor will be covered by the Fabrication Specifications developed by the Prime Contractor based on this document and approved by

  15. Insertion profiles of 4 headless compression screws.

    Science.gov (United States)

    Hart, Adam; Harvey, Edward J; Lefebvre, Louis-Philippe; Barthelat, Francois; Rabiei, Reza; Martineau, Paul A

    2013-09-01

    In practice, the surgeon must rely on screw position (insertion depth) and tactile feedback from the screwdriver (insertion torque) to gauge compression. In this study, we identified the relationship between interfragmentary compression and these 2 factors. The Acutrak Standard, Acutrak Mini, Synthes 3.0, and Herbert-Whipple implants were tested using a polyurethane foam scaphoid model. A specialized testing jig simultaneously measured compression force, insertion torque, and insertion depth at half-screw-turn intervals until failure occurred. The peak compression occurs at an insertion depth of -3.1 mm, -2.8 mm, 0.9 mm, and 1.5 mm for the Acutrak Mini, Acutrak Standard, Herbert-Whipple, and Synthes screws respectively (insertion depth is positive when the screw is proud above the bone and negative when buried). The compression and insertion torque at a depth of -2 mm were found to be 113 ± 18 N and 0.348 ± 0.052 Nm for the Acutrak Standard, 104 ± 15 N and 0.175 ± 0.008 Nm for the Acutrak Mini, 78 ± 9 N and 0.245 ± 0.006 Nm for the Herbert-Whipple, and 67 ± 2N, 0.233 ± 0.010 Nm for the Synthes headless compression screws. All 4 screws generated a sizable amount of compression (> 60 N) over a wide range of insertion depths. The compression at the commonly recommended insertion depth of -2 mm was not significantly different between screws; thus, implant selection should not be based on compression profile alone. Conically shaped screws (Acutrak) generated their peak compression when they were fully buried in the foam whereas the shanked screws (Synthes and Herbert-Whipple) reached peak compression before they were fully inserted. Because insertion torque correlated poorly with compression, surgeons should avoid using tactile judgment of torque as a proxy for compression. Knowledge of the insertion profile may improve our understanding of the implants, provide a better basis for comparing screws, and enable the surgeon to optimize compression. Copyright

  16. An ordered, nonredundant library of Pseudomonas aeruginosa strain PA14 transposon insertion mutants

    OpenAIRE

    Liberati, Nicole T.; Urbach, Jonathan M.; Miyata, Sachiko; Lee, Daniel G.; Drenkard, Eliana; Wu, Gang; Villanueva, Jacinto; Wei, Tao; Ausubel, Frederick M.

    2006-01-01

    Random transposon insertion libraries have proven invaluable in studying bacterial genomes. Libraries that approach saturation must be large, with multiple insertions per gene, making comprehensive genome-wide scanning difficult. To facilitate genome-scale study of the opportunistic human pathogen Pseudomonas aeruginosa strain PA14, we constructed a nonredundant library of PA14 transposon mutants (the PA14NR Set) in which nonessential PA14 genes are represented by a single transposon insertio...

  17. Utility Bill Insert for Wastewater Services

    Science.gov (United States)

    Intended for use by wastewater and water supply utilities, one side of the utility bill insert has information for customers that discharge to sanitary sewer systems; the other side is for customers with septic systems.

  18. HB+ inserted into the CMS Solenoid

    CERN Multimedia

    Tejinder S. Virdee, CERN

    2006-01-01

    The first half of the barrel hadron calorimeter (HB+) has been inserted into the superconducting solenoid of CMS, in preparation for the magnet test and cosmic challenge. The operation went smoothly, lasting a couple of days.

  19. Peripherally inserted central catheter - dressing change

    Science.gov (United States)

    PICC - dressing change ... You have a peripherally inserted central catheter (PICC). This is a tube that goes into a vein in your arm. It carries nutrients and medicines into your body. It may also ...

  20. Bulkhead insert for an internal combustion engine

    Science.gov (United States)

    Maki, Clifford E.; Chottiner, Jeffrey Eliot; Williams, Rick L.; Thibault, Mark W.; Ervin, James Douglas; Boileau, James Maurice; McKeough, Bryan

    2017-08-01

    An engine includes a cylinder block defining at least one main bearing bulkhead adjacent to a cylinder, and a crankshaft rotatably housed within the block by a main bearing. A bulkhead insert has a cap portion, and an insert portion provided within the bulkhead. The insert portion has having first and second end regions connected by first and second straps. Each strap having a flanged beam cross section. The first and second ends of the insert portion are configured to connect a main bearing cap column to a cylinder head column. Each of the first and second end regions define at least one protrusion having a surface substantially normal to engine combustion and reactive loads. The cap portion is configured to mate with the first end region at the main bearing cap column and support the main bearing.

  1. Inserting Stress Analysis of Combined Hexagonal Aluminum Honeycombs

    Directory of Open Access Journals (Sweden)

    Xiangcheng Li

    2016-01-01

    Full Text Available Two kinds of hexagonal aluminum honeycombs are tested to study their out-of-plane crushing behavior. In the tests, honeycomb samples, including single hexagonal aluminum honeycomb (SHAH samples and two stack-up combined hexagonal aluminum honeycombs (CHAH samples, are compressed at a fixed quasistatic loading rate. The results show that the inserting process of CHAH can erase the initial peak stress that occurred in SHAH. Meanwhile, energy-absorbing property of combined honeycomb samples is more beneficial than the one of single honeycomb sample with the same thickness if the two types of honeycomb samples are completely crushed. Then, the applicability of the existing theoretical model for single hexagonal honeycomb is discussed, and an area equivalent method is proposed to calculate the crushing stress for nearly regular hexagonal honeycombs. Furthermore, a semiempirical formula is proposed to calculate the inserting plateau stress of two stack-up CHAH, in which structural parameters and mechanics properties of base material are concerned. The results show that the predicted stresses of three kinds of two stack-up combined honeycombs are in good agreement with the experimental data. Based on this study, stress-displacement curve of aluminum honeycombs can be designed in detail, which is very beneficial to optimize the energy-absorbing structures in engineering fields.

  2. [Peripherally inserted central catheter antibiotic therapy for cystic fibrosis patients].

    Science.gov (United States)

    Betegnie, A-L; Cracowski, C; Bedouch, P; Segond, C; Robein-Dobremez, M-J; Pin, I; Allenet, B

    2014-11-01

    Peripherally inserted central catheters (PICC) are more and more used for intravenous antibiotic infusions in cystic fibrosis (CF) patients in the Grenoble area (France). The aim of this study was to assess the use of this technique in this indication. 1. Retrospective evaluation of 102 consecutive PICC insertions over 3years and the incidence of adverse events during the therapy. 2. Prospective evaluation of 12 patient's satisfaction and their nurses over a 3-month period. 3. Comparative analysis of single domiciliary treatment costs using PICC versus peripheral catheter (PC). 102 PICC insertions were attempted in 31 patients. Seven failures and 7 complications occurred during the treatment requiring removal of the PICC, i.e. an overall success rate of 86.2% (88/102). Pain during PICC introduction was 4.2/10 (visual analogical scale). Mean satisfaction levels during therapy were 9.3/10 for patients and 8.7/10 for nurses. Compared with PC, all the patients said that PICC was "more comfortable". Differential costs of treatment with PC and with PICC at home were estimated at 57.15€ and 590.16€ respectively. PICC is an alternative to CP for intravenous antibiotherapy in CF patients, providing better safety and comfort. PICC use should be promoted in this indication. Copyright © 2013 SPLF. Published by Elsevier Masson SAS. All rights reserved.

  3. Beam search filtrado com inserção de ociosidade na programação de uma máquina em ambiente do tipo jit Filtered beam search with ociosity insertion for single machine scheduling in a jit environment

    Directory of Open Access Journals (Sweden)

    Emerson Carlos Colin

    1998-08-01

    Full Text Available Este trabalho avalia a utilização do beam search filtrado (BSF combinado com um algoritmo de inserção de ociosidade (AIO. O caso estudado é baseado em uma única máquina, com datas de entrega múltiplas e com penalidades distintas de adiantamento e de atraso para cada ordem. O objetivo a ser alcançado é a minimização do custo total. Para isso, o BSF é utilizado para gerar as seqüências, e o AIO, para definir os programas. Assume-se que a dificuldade de solução do problema é dependente de dois parâmetros: fator de atraso médio e amplitude relativa das datas de entrega. Testes empíricos comparativos são realizados por meio de simulação computacional, no qual se mede o tempo de solução e o valor alcançado pela função-objetivo. Os resultados indicam que de uma forma geral, o procedimento proposto propicia uma diminuição no custo total e, além disso, que para a escolha de um procedimento apropriado, o ideal é se conhecer o valor dos parâmetros.This work evaluates the use of a filtered beam search (FBS combined with an ociosity insertion algorithm (OIA. The case studied is based on a single machine, with multiple due dates, and distinct earliness and tardiness penalties for each job. The objective function is to minimize total cost. For this, the FBS is used to construct sequences, and the OIA is used to obtain schedules. It is assumed that the degree of difficulty of solving the problem is dependent on two parameters: average tardiness factor and relative range of due dates. Comparative empirical tests were conducted with computational simulation, where computational solution time and the objective function value were evaluated. The results indicate that in general, the proposed procedure favours a decrease in total cost and, in addition, that before choosing an appropriate procedure, the ideal situation is to know the value of the parameters.

  4. Hamstring tendons insertion - an anatomical study

    Directory of Open Access Journals (Sweden)

    Cristiano Antonio Grassi

    2013-09-01

    Full Text Available OBJECTIVE: To study the anatomy of the hamstring tendons insertion and anatomical rela-tionships. METHODS: Ten cadaver knees with medial and anterior intact structures were selected. The dissection was performed from anteromedial access to exposure of the insertion of the flexor tendons (FT, tibial plateau (TP and tibial tuberosity (TT. A needle of 40 × 12 and a caliper were used to measure the distance of the tibial plateau of the knee flexor tendons insertion at 15 mm from the medial border of the patellar tendon and tibial tuberosity to the insertion of the flexor tendons of the knee. The angle between tibial plateau and the insertion of the flexor tendons of the knee (A-TP-FT was calculated using Image Pro Plus software. RESULTS: The mean distance TP-FT was 41 ± 4.6 mm. The distance between the TT-FT was 6.88 ± 1 mm. The (A-TP-FT was 20.3 ± 4.9°. CONCLUSION: In the anterior tibial flexor tendons are about 40 mm from the plateau with an average of 20°.

  5. Test manufacture of a canister insert

    International Nuclear Information System (INIS)

    Raiko, H.

    2004-11-01

    This report describes the insert-manufacturing test of a disposal canister for spent nuclear fuel that was made by Metso Paper Oy, Jyvaeskylae Foundry, in 2003 on contract for Posiva Oy. The test manufacture was a part of the co-operation development programme of encapsulation technology between SKB AB and Posiva Oy. Insert casting was specified according to the current manufacturing specifications of SKB. The canister insert was of BWR-type with integral bottom. This was the first trial manufacture of this type of insert in Finland and, in total, the second test manufacture of insert by Metso Paper. The result fulfilled all the requirements but the material mechanical properties and metallurgical structure of the cast material. The measured tensile strength, ultimate strength and elongation at rupture were lower than specified. The reason for this was revealed in the metallurgical investigation of the cast material. The nodulizing of the graphite was not occurred during the casting process according to the requirements. (orig.)

  6. Assessment of Insert Sizes and Adapter Content in Fastq Data from NexteraXT Libraries

    Directory of Open Access Journals (Sweden)

    Frances Susan Turner

    2014-01-01

    Full Text Available The Illumina NexteraXT transposon protocol is a cost effective way to generate paired end libraries. However the resulting insert size is highly sensitive to the concentration of DNA used, and the variation of insert sizes is often large. One consequence of this is some fragments may have an insert shorter than the length of a single read, particularly where the library is designed to produce overlapping paired end reads in order to produce longer continuous sequences. Such small insert sizes mean fewer longer reads, and also result in the presence of adapter at the end of the read. Here is presented a protocol to use publicly available tools to identify read pairs with small insert sizes and so likely to contain adapter, to check the sequence of the adapter, and remove adapter sequence from the reads. This protocol does not require a reference genome or prior knowledge of the sequence to be trimmed. Whilst the presence of fragments with small insert sizes may be a particular problem for NexteraXT libraries, the principle can be applied to any Illumina dataset in which the presence of such small inserts is suspected.

  7. Confirming PICC tip position during insertion with real-time information.

    Science.gov (United States)

    Barton, Andrew

    2016-01-27

    Peripherally inserted central catheters (PICCs) play a fundamental role in patient care in a variety of clinical and healthcare settings. Tip location is important for both safety and efficacy. New technologies may offer the possibility of safer, more efficient and more effective insertion. A prospective evaluation was carried out of a system providing real-time information on the tip's location, direction, and depth during insertion in a total of 488 patients at a single centre (65 patients in the initial study, plus follow-on case series reports in 423 patients). No tip malpositions were reported and, as a result, the institution has been able to waive the requirement for confirmatory chest X-ray after PICC insertion, thus minimising the delay before the PICC can be used and increasing staff and patient confidence in the procedure.

  8. ALS insertion device block measurement and inspection

    International Nuclear Information System (INIS)

    Marks, S.; Carrieri, J.; Cook, C.; Hassenzahl, W.V.; Hoyer, E.; Plate, D.

    1991-05-01

    The performance specifications for ALS insertion devices require detailed knowledge and strict control of the Nd-Fe-B permanent magnet blocks incorporated in these devices. This paper describes the measurement and inspection apparatus and the procedures designed to qualify and characterize these blocks. A detailed description of a new, automated Helmholtz coil facility for measurement of the three components of magnetic moment is included. Physical block inspection and magnetic moment measurement procedures are described. Together they provide a basis for qualifying blocks and for specifying placement of blocks within an insertion devices' magnetic structures. 1 ref., 4 figs

  9. Compact insert design for cryogenic pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Aceves, Salvador M.; Ledesma-Orozco, Elias Rigoberto; Espinosa-Loza, Francisco; Petitpas, Guillaume; Switzer, Vernon A.

    2017-06-14

    A pressure vessel apparatus for cryogenic capable storage of hydrogen or other cryogenic gases at high pressure includes an insert with a parallel inlet duct, a perpendicular inlet duct connected to the parallel inlet. The perpendicular inlet duct and the parallel inlet duct connect the interior cavity with the external components. The insert also includes a parallel outlet duct and a perpendicular outlet duct connected to the parallel outlet duct. The perpendicular outlet duct and the parallel outlet duct connect the interior cavity with the external components.

  10. Insertional Mutagenesis by a Hybrid PiggyBac and Sleeping Beauty Transposon in the Rat

    Science.gov (United States)

    Furushima, Kenryo; Jang, Chuan-Wei; Chen, Diane W.; Xiao, Ningna; Overbeek, Paul A.; Behringer, Richard R.

    2012-01-01

    A hybrid piggyBac/Sleeping Beauty transposon-based insertional mutagenesis system that can be mobilized by simple breeding was established in the rat. These transposons were engineered to include gene trap sequences and a tyrosinase (Tyr) pigmentation reporter to rescue the albinism of the genetic background used in the mutagenesis strategy. Single-copy transposon insertions were transposed into the rat genome by co-injection of plasmids carrying the transposon and RNA encoding piggyBac transposase into zygotes. The levels of transgenic Tyr expression were influenced by chromosomal context, leading to transgenic rats with different pigmentation that enabled visual genotyping. Transgenic rats designed to ubiquitously express either piggyBac or Sleeping Beauty transposase were generated by standard zygote injection also on an albino background. Bigenic rats carrying single-copy transposons at known loci and transposase transgenes exhibited coat color mosaicism, indicating somatic transposition. PiggyBac or Sleeping Beauty transposase bigenic rats bred with wild-type albino rats yielded offspring with pigmentation distinct from the initial transposon insertions as a consequence of germline transposition to new loci. The germline transposition frequency for Sleeping Beauty and piggyBac was ∼10% or about one new insertion per litter. Approximately 50% of the insertions occurred in introns. Chimeric transcripts containing endogenous and gene trap sequences were identified in Gabrb1 mutant rats. This mutagenesis system based on simple crosses and visual genotyping can be used to generate a collection of single-gene mutations in the rat. PMID:23023007

  11. Insertion Loss of Personal Protective Clothing

    International Nuclear Information System (INIS)

    Shull, D.J.

    1999-01-01

    The use of personal protective clothing that covers the head is a common practice in many industries. Such personal protective clothing will impact the sound pressure level and the frequency content of sounds to which the wearer will be exposed. The use of such clothing, then, may impact speech and alarm audibility. A measure of the impact of such clothing is its insertion loss. Insertion loss measurements were performed on four types of personal protective clothing in use by Westinghouse Savannah River Company personnel which utilize cloth and plastic hood configurations to protect the head. All clothing configurations tested at least partially cover the ears. The measurements revealed that insertion loss of the items tested was notable at frequencies above 1000 Hz only and was a function of material stiffness and acoustic flanking paths to the ear. Further, an estimate of the clothing's noise reduction rating reveals poor performance in that regard, even though the insertion loss of the test articles was significant at frequencies at and above 1000 Hz.'

  12. Direct random insertion mutagenesis of Helicobacter pylori

    NARCIS (Netherlands)

    de Jonge, Ramon; Bakker, Dennis; van Vliet, Arnoud H. M.; Kuipers, Ernst J.; Vandenbroucke-Grauls, Christina M. J. E.; Kusters, Johannes G.

    2003-01-01

    Random insertion mutagenesis is a widely used technique for the identification of bacterial virulence genes. Most strategies for random mutagenesis involve cloning in Escherichia coli for passage of plasmids or for phenotypic selection. This can result in biased selection due to restriction or

  13. Aspects of insertion in random trees

    NARCIS (Netherlands)

    Bagchi, Arunabha; Reingold, E.M.

    1982-01-01

    A method formulated by Yao and used by Brown has yielded bounds on the fraction of nodes with specified properties in trees bult by a sequence of random internal nodes in a random tree built by binary search and insertion, and show that in such a tree about bounds better than those now known. We

  14. SOLVENTLESS MIGRATORY-INSERTION REACTIONS OF ...

    African Journals Online (AJOL)

    Preferred Customer

    2CH3 and PPh3 as well as CO ligands in the absence of solvent was reported by us. [18]. In this study we report on the influence of steric and electronic effects of the incoming ligand on the insertion reaction and evaluate a green chemistry ...

  15. Patients' experiences of the PICC insertion procedure.

    Science.gov (United States)

    Nicholson, Jackie; Davies, Louise

    Peripherally inserted central catheters (PICCs) are a type of central venous access device used to deliver a variety of intravenous therapies, including chemotherapy. PICCs may be placed by interventional radiologists, anaesthetists or, as is increasingly common, by specialist nurses in the hospital setting. However, little is known about how patients feel regarding the PICC insertion procedure. The aim of this study was to interview patients who had undergone a recent PICC insertion in the chemotherapy day unit to identify their experiences. On analysis of the qualitative data obtained from the semi-structured interview, five themes emerged: the context of cancer; expectations; levels of pain and anxiety; coping strategies; and explanation. The findings of this study support some previously described elements of procedural experiences; however, new understanding has provided implications for practice in the areas of expectations, allaying anxiety levels, supporting individual coping strategies and providing explanation. The major limitation of the study was the homogenous sample of oncology patients with a clear link between the patient experience of the PICC insertion and the context of cancer. The main recommendation for further research would be to repeat this study with a broader patient population.

  16. Isolation and characterization of functional tripartite group II introns using a Tn5-based genetic screen.

    Directory of Open Access Journals (Sweden)

    Christine Ritlop

    Full Text Available BACKGROUND: Group II introns are RNA enzymes that splice themselves from pre-mRNA transcripts. Most bacterial group II introns harbour an open reading frame (ORF, coding for a protein with reverse transcriptase, maturase and occasionally DNA binding and endonuclease activities. Some ORF-containing group II introns were shown to be mobile retroelements that invade new DNA target sites. From an evolutionary perspective, group II introns are hypothesized to be the ancestors of the spliceosome-dependent nuclear introns and the small nuclear RNAs (snRNAs--U1, U2, U4, U5 and U6 that are important functional elements of the spliceosome machinery. The ability of some group II introns fragmented in two or three pieces to assemble and undergo splicing in trans supports the theory that spliceosomal snRNAs evolved from portions of group II introns. METHODOLOGY/PRINCIPAL FINDINGS: We used a transposon-based genetic screen to explore the ability of the Ll.LtrB group II intron from the Gram-positive bacterium Lactococcus lactis to be fragmented into three pieces in vivo. Trans-splicing tripartite variants of Ll.LtrB were selected using a highly efficient and sensitive trans-splicing/conjugation screen. We report that numerous fragmentation sites located throughout Ll.LtrB support tripartite trans-splicing, showing that this intron is remarkably tolerant to fragmentation. CONCLUSIONS/SIGNIFICANCE: This work unveils the great versatility of group II intron fragments to assemble and accurately trans-splice their flanking exons in vivo. The selected introns represent the first evidence of functional tripartite group II introns in bacteria and provide experimental support for the proposed evolutionary relationship between group II introns and snRNAs.

  17. A critical appraisal of medication package inserts

    Directory of Open Access Journals (Sweden)

    Pranjit Narzaree

    2015-10-01

    Full Text Available Introduction: Package Inserts (PIs refers to officially specified document that accompanies a drug for relevant, updated and unbiased information for rational drug use based on regulatory guidelines as per section 6.2 and 6.3 of schedule D of Indian Drug and cosmetic Act 1945. But some studies had shown non-uniformity with suboptimal level of informations which frequently can lead to medication errors. Hence this study was conducted to evaluate the completeness of PIs.Aim: To critically evaluate package inserts of allopathic medicines.Material and Methods: 100 allopathic drug PIs were collected from pharmacies in Rohtak and were checked for the presence of each heading as per schedule D criteria, followed by scrutiny of the information included under the heading. Indian guidelines were also compared with US FDA guidelines for PIs.Scoring of package inserts: The informations were evaluated for completeness and scored as 1 if present otherwise scored as zero for no information or partial information. Scores for each heading were calculated by totaling the scores of all the package inserts. The total scores were expressed as absolute numbers and percentages.Results:  On an average PIs analyzed for the completeness of the criteria scored 10 (Mean± SD = 9.73±2.48 out of 16. Absence of common layout and headings caused inconvenience. In comparison to US FDA guidelines it lacked, disclaimer statement, boxed warning, revision date, approval date, toll-free number etc.Conclusion: PIs don’t seem to be serving effectively because of multiple deficiencies like completeness, uniformity, absence of headings.Keywords: Critical appraisal, package inserts.

  18. COMPARATIVE STUDY OF EARLY POSTPARTUM IUCD INSERTION TO INTERVAL IUCD INSERTION

    Directory of Open Access Journals (Sweden)

    Shibani Devi

    2016-07-01

    Full Text Available INTRODUCTION According to National Family Health Survey-3, Indian women have 13% unmet need for contraception and according to District Level Household & Facility Survey-3, it is 21.3% in the postpartum period. Postpartum intrauterine contraceptive device insertion - both immediately post-placental delivery and somewhat later, but within 48 hours after delivery are options which merit consideration as the woman is likely to have a high motivation for accepting contraception and the healthcare centre provides a convenient setting for insertion of IUCD. AIM Comparison of efficacy and complications of IUCD insertions in post-placental with interval period: 6-month followup. METHOD This perspective study was conducted among 100 women: - 50 women had IUCD inserted within 10 minutes of placental delivery and 50 had insertion more than 6 weeks after delivery. They were followed till 6 months post insertion and were compared regarding early and late complications, continuation rates and expulsion rates. RESULT At the end of six months, we found higher occurrence of lower abdominal pain, heavy menstrual bleeding in case of interval insertion as compared to post-placental insertion which was statistically significant (p value-0.04 & 0.007 respectively. However, the expulsion rates of post-placental IUCD were somewhat elevated (14% compared to interval insertions (2%. Continuation rates at the end of 6 months in both the groups were 82% and 86% respectively which is comparable. CONCLUSION Post-placental IUCD is thus found to be an ideal method to meet the unmet need of postpartum women as it is easily accessible and convenient for both women and their health care providers, is associated with less discomfort and fewer side effects and allow women to obtain safe, long acting, highly effective contraception while still in the health care system.

  19. Medications to ease intrauterine device insertion: a systematic review.

    Science.gov (United States)

    Zapata, Lauren B; Jatlaoui, Tara C; Marchbanks, Polly A; Curtis, Kathryn M

    2016-12-01

    Potential barriers to intrauterine device (IUD) use include provider concern about difficult insertion, particularly for nulliparous women. This study aims to evaluate the evidence on the effectiveness of medications to ease IUD insertion on provider outcomes (i.e., ease of insertion, need for adjunctive insertion measures, insertion success). We searched the PubMed database for peer-reviewed articles published in any language from database inception through February 2016. We included randomized controlled trials (RCTs) that examined medications to ease interval insertion of levonorgestrel-releasing IUDs and copper T IUDs. From 1855 articles, we identified 15 RCTs that met our inclusion criteria. Most evidence suggested that misoprostol did not improve provider ease of insertion, reduce the need for adjunctive insertion measures or improve insertion success among general samples of women seeking an IUD (evidence Level I, good to fair). However, one RCT found significantly higher insertion success among women receiving misoprostol prior to a second IUD insertion attempt after failed attempt versus placebo (evidence Level I, good). Two RCTs on 2% intracervical lidocaine as a topical gel or injection suggested no positive effect on provider ease of insertion (evidence Level I, good to poor), and one RCT on diclofenac plus 2% intracervical lidocaine as a topical gel suggested no positive effect on provider ease of insertion (evidence Level I, good). Limited evidence from two RCTs on nitric oxide donors, specifically nitroprusside or nitroglycerin gel, suggested no positive effect on provider ease of insertion or need for adjunctive insertion measures (evidence Level I, fair). Overall, most studies found no significant differences between women receiving interventions to ease IUD insertion versus controls. Among women with a recent failed insertion who underwent a second insertion attempt, one RCT found improved insertion success among women using misoprostol versus

  20. Effects of insertion speed and trocar stiffness on the accuracy of needle position for brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    McGill, Carl S.; Schwartz, Jonathon A.; Moore, Jason Z.; McLaughlin, Patrick W.; Shih, Albert J. [Biomedical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109 (United States); Department of Mechanical and Nuclear Engineering, The Pennsylvania State University, State College, Pennsylvania 16802 (United States); Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan 48109 (United States); Biomedical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109 and Mechanical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109 (United States)

    2012-04-15

    Purpose: In prostate brachytherapy, accurate positioning of the needle tip to place radioactive seeds at its target site is critical for successful radiation treatment. During the procedure, needle deflection leads to seed misplacement and suboptimal radiation dose to cancerous cells. In practice, radiation oncologists commonly use high-speed hand needle insertion to minimize displacement of the prostate as well as the needle deflection. Effects of speed during needle insertion and stiffness of trocar (a solid rod inside the hollow cannula) on needle deflection are studied. Methods: Needle insertion experiments into phantom were performed using a 2{sup 2} factorial design (2 parameters at 2 levels), with each condition having replicates. Analysis of the deflection data included calculating the average, standard deviation, and analysis of variance (ANOVA) to find significant single and two-way interaction factors. Results: The stiffer tungsten carbide trocar is effective in reducing the average and standard deviation of needle deflection. The fast insertion speed together with the stiffer trocar generated the smallest average and standard deviation for needle deflection for almost all cases. Conclusions: The combination of stiff tungsten carbide trocar and fast needle insertion speed are important to decreasing needle deflection. The knowledge gained from this study can be used to improve the accuracy of needle insertion during brachytherapy procedures.

  1. Comparison of conventional Injection Mould Inserts to Additively Manufactured Inserts using Life Cycle Assessment

    DEFF Research Database (Denmark)

    Hofstätter, Thomas; Bey, Niki; Mischkot, Michael

    2016-01-01

    Polymer Additive Manufacturing can be used to produce soft tooling inserts for injection moulding. Compared to conventional tooling, the energy and time consumption during production are significantly lower. As the life time of such inserts is significantly shorter than the life time of traditional...... of their potential environmental impact and yield throughout the development and pilot phase. Insert geometry is particularly advantageous for pilot production and small production sizes. In this research, Life Cycle Assessment is used to compare the environmental impact of soft tooling by Additive Manufacturing...... (using Digital Light Processing) and three traditional methods for the manufacture of inserts (milling of brass, steel, and aluminium) for injection moulds during the pre-production phase....

  2. Augmentation of localized defects of the anterior maxillary ridge with autogenous bone before insertion of implants

    NARCIS (Netherlands)

    Raghoebar, GM; Batenburg, RHK; Vissink, A; Reintsema, H

    1996-01-01

    Purpose: This study evaluated the applicability of intraorally harvested autogenous bone grafts for the augmentation of the narrow maxillary alveolar ridge to enable insertion of implants for single tooth replacement. Materials and Methods: Local defects of the anterior maxilla were reconstructed in

  3. Insertion-Sequence-Mediated Mutations Isolated During Adaptation to Growth and Starvation in Lactococcus lactis.

    NARCIS (Netherlands)

    Visser, de J.A.G.M.; Akkermans, A.D.L.; Hoekstra, R.F.; Vos, de W.M.

    2004-01-01

    We studied the activity of three multicopy insertion sequence (IS) elements in 12 populations of Lactococcus lactis IL1403 that evolved in the laboratory for 1000 generations under various environmental conditions (growth or starvation and shaken or stationary). Using RFLP analysis of single-clone

  4. Machine-vision-based identification of broken inserts in edge profile milling heads

    NARCIS (Netherlands)

    Fernandez Robles, Laura; Azzopardi, George; Alegre, Enrique; Petkov, Nicolai

    This paper presents a reliable machine vision system to automatically detect inserts and determine if they are broken. Unlike the machining operations studied in the literature, we are dealing with edge milling head tools for aggressive machining of thick plates (up to 12 centimetres) in a single

  5. Flat midsubstance of the anterior cruciate ligament with tibial "C"-shaped insertion site.

    Science.gov (United States)

    Siebold, Rainer; Schuhmacher, Peter; Fernandez, Francis; Śmigielski, Robert; Fink, Christian; Brehmer, Axel; Kirsch, Joachim

    2015-11-01

    This anatomical cadaver study was performed to investigate the flat appearance of the midsubstance shape of the anterior cruciate ligament (ACL) and its tibial "C"-shaped insertion site. The ACL midsubstance and the tibial ACL insertion were dissected in 20 cadaveric knees (n = 6 fresh frozen and n = 14 paraffined). Magnifying spectacles were used for all dissections. Morphometric measurements were performed using callipers and on digital photographs. In all specimens, the midsubstance of the ACL was flat with a mean width of 9.9 mm, thickness of 3.9 mm and cross-sectional area of 38.7 mm(2). The "direct" "C"-shaped tibial insertion runs from along the medial tibial spine to the anterior aspect of the lateral meniscus. The mean width (length) of the "C" was 12.6 mm, its thickness 3.3 mm and area 31.4 mm(2). The centre of the "C" was the bony insertion of the anterior root of the lateral meniscus overlayed by fat and crossed by the ACL. No posterolateral (PL) inserting ACL fibres were found. Together with the larger "indirect" part (area 79.6 mm(2)), the "direct" one formed a "duck-foot"-shaped footprint. The tibial ACL midsubstance and tibial "C"-shaped insertion are flat and are resembling a "ribbon". The centre of the "C" is the bony insertion of the anterior root of the lateral meniscus. There are no central or PL inserting ACL fibres. Anatomical ACL reconstruction may therefore require a flat graft and a "C"-shaped tibial footprint reconstruction with an anteromedial bone tunnel for single bundle and an additional posteromedial bone tunnel for double bundle.

  6. Symplectic models for general insertion devices

    International Nuclear Information System (INIS)

    Wu, Y.; Forest, E.; Robin, D. S.; Nishimura, H.; Wolski, A.; Litvinenko, V. N.

    2001-01-01

    A variety of insertion devices (IDs), wigglers and undulators, linearly or elliptically polarized,are widely used as high brightness radiation sources at the modern light source rings. Long and high-field wigglers have also been proposed as the main source of radiation damping at next generation damping rings. As a result, it becomes increasingly important to understand the impact of IDs on the charged particle dynamics in the storage ring. In this paper, we report our recent development of a general explicit symplectic model for IDs with the paraxial ray approximation. High-order explicit symplectic integrators are developed to study real-world insertion devices with a number of wiggler harmonics and arbitrary polarizations

  7. Two cases of anaphylaxis after laminaria insertion.

    Science.gov (United States)

    Kim, Sang-Hoon; Chang, Yun-Hae; Kim, Woo-Kyoung; Kim, Yoon-Keun; Cho, Sang-Heon; Kim, You-Young; Min, Kyung-Up

    2003-01-01

    Anaphylaxis following laminaria insertion rarely occurs but may be a life-threatening condition. Laminaria tents, prepared from natural sea kelp, are commonly used prior to elective termination of pregnancy to achieve cervical dilatation. We report herein two cases of anaphylaxis caused by IgE-mediated hypersensitivity to laminaria. Two women, each of whom had undergone at least one previous abortion where a laminaria had been utilized, developed anaphylactic reaction following laminaria insertion. The reaction included urticaria, nausea, breathing difficulty, and hypotension. The patients subsequently underwent skin testing and measurement of serum specific IgE level to laminaria extract, and were shown to elicit positive responses to laminaria. The implication and impact of laminaria allergy on gynecologic procedures are significant and this allergy should be included in the list of differential diagnoses for hypersensitive reaction in gynecologic procedures. PMID:14676449

  8. HrcQ is necessary for Xanthomonas oryzae pv. oryzae HR-induction in non-host tobacco and pathogenicity in host rice

    Directory of Open Access Journals (Sweden)

    Xiaoping Zhang

    2013-12-01

    Full Text Available Bacterial blight, caused by Xanthomonas oryzae pv. oryzae (Xoo, is one of the most destructive diseases of rice (Oryza sativa L. worldwide. The type III secretion system (T3SS of Xoo, encoded by the hrp (hypersensitive response and pathogenicity genes, plays critical roles in conferring pathogenicity in host rice and triggering a hypersensitive response (HR in non-host plants. To investigate the major genes conferring the pathogenicity and avirulence of Xoo, we previously constructed a random Tn5-insertion mutant library of Xoo strain PXO99A. We report here the isolation and characterization of a Tn5-insertion mutant PXM69. Tn5-insertion mutants were screened on indica rice JG30, which is highly susceptible to PXO99A, by leaf-cutting inoculation. Four mutants with reduced virulence were obtained after two rounds of screening. Among them, the mutant PXM69 had completely lost virulence to the rice host and ability to elicit HR in non-host tobacco. Southern blotting analysis showed a single copy of a Tn5-insertion in the genome of PXM69. PCR walking and sequencing analysis revealed that the Tn5 transposon was inserted at nucleotide position 70,192–70,201 in the genome of PXO99A, disrupting the type III hrc (hrp-conserved gene hrcQ, the first gene in the D operon of the hrp cluster in Xoo. To confirm the relationship between the Tn5-insertion and the avirulence phenotype of PXM69, we used the marker exchange mutagenesis to create a PXO99A mutant, ΔhrcQ::KAN, in which the hrcQ was disrupted by a kanamycin-encoding gene cassette at the same site as that of the Tn5-insertion. ΔhrcQ::KAN showed the same phenotype as mutant PXM69. Reintroduction of the wild-type hrcQ gene partially complemented the pathogenic function of PXM69. RT-PCR and cellulase secretion assays showed that the Tn5-disruption of hrcQ did not affect transcription of downstream genes in the D operon and function of the type II secretion system. Our results provide new insights into

  9. Probabilistic phylogenetic inference with insertions and deletions.

    Directory of Open Access Journals (Sweden)

    Elena Rivas

    2008-09-01

    Full Text Available A fundamental task in sequence analysis is to calculate the probability of a multiple alignment given a phylogenetic tree relating the sequences and an evolutionary model describing how sequences change over time. However, the most widely used phylogenetic models only account for residue substitution events. We describe a probabilistic model of a multiple sequence alignment that accounts for insertion and deletion events in addition to substitutions, given a phylogenetic tree, using a rate matrix augmented by the gap character. Starting from a continuous Markov process, we construct a non-reversible generative (birth-death evolutionary model for insertions and deletions. The model assumes that insertion and deletion events occur one residue at a time. We apply this model to phylogenetic tree inference by extending the program dnaml in phylip. Using standard benchmarking methods on simulated data and a new "concordance test" benchmark on real ribosomal RNA alignments, we show that the extended program dnamlepsilon improves accuracy relative to the usual approach of ignoring gaps, while retaining the computational efficiency of the Felsenstein peeling algorithm.

  10. Fixed mask assembly research for APS insertion devices

    International Nuclear Information System (INIS)

    Kuzay, T.M.

    1992-01-01

    The Fixed Mask Assembly (FMA) is the first component to interact with the photon beam. Two sets of a pair of FMA channels, vertically and horizontally disposed, contain the beam rather than define it. They are subject to very large heat fluxes during containment. In current practice, the FMA channels are made of heavy, seamless copper, have rectangular cross-sections, and are cooled internally with water. Channels are set at grazing angles ranging from I to 6 degrees with respect to the beam, depending on the type of insertion device. APS insertion devices will impose higher heat fluxes on FMAS. Therefore, a need exists to improve the FMA engineering, keeping in mind the current design criteria and philosophy of FMAS. Preliminary analysis of current heat transfer practice indicates that the major resistance to heat transfer is on the coolant side. Therefore, FMA cooling would benefit from enhanced heat transfer on the coolant side. With this principle in mind, an experimental program has been undertaken to explore the feasibility of using high-performance copper tube configurations which are expected to yield heat transfer coefficients, open-quotes hclose quotes, in single phase flow systems 2 to 5(?) times higher than equivalent plain tubes. In this report, the experimental scope and a preliminary analysis of high-performance copper tube configurations are described

  11. Combined heart-kidney transplantation after total artificial heart insertion.

    Science.gov (United States)

    Ruzza, A; Czer, L S C; Ihnken, K A; Sasevich, M; Trento, A; Ramzy, D; Esmailian, F; Moriguchi, J; Kobashigawa, J; Arabia, F

    2015-01-01

    We present the first single-center report of 2 consecutive cases of combined heart and kidney transplantation after insertion of a total artificial heart (TAH). Both patients had advanced heart failure and developed dialysis-dependent renal failure after implantation of the TAH. The 2 patients underwent successful heart and kidney transplantation, with restoration of normal heart and kidney function. On the basis of this limited experience, we consider TAH a safe and feasible option for bridging carefully selected patients with heart and kidney failure to combined heart and kidney transplantation. Recent FDA approval of the Freedom driver may allow outpatient management at substantial cost savings. The TAH, by virtue of its capability of providing pulsatile flow at 6 to 10 L/min, may be the mechanical circulatory support device most likely to recover patients with marginal renal function and advanced heart failure. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Theoretical and experimental investigation of the insertion loss of a dissipative muffler

    DEFF Research Database (Denmark)

    Pommer, Christian; Tarnow, Viggo

    1986-01-01

    formulas of the propagation constant and specific impedance of a dissipative porous material. The insertion loss of a single chamber dissipative muffler was calculated for different geometries and dissipative materials, and the insertion loss was measured using two microphone probes and white noise....... The measurements were performed with different geometries and with different porous materials. The acoustical properties of the porous materials were calculated on the basis of the measured flow resistance and the calculated acoustical properties were compared with results obtained by using a standing wave tube...

  13. Tracking marsupial evolution using archaic genomic retroposon insertions.

    Directory of Open Access Journals (Sweden)

    Maria A Nilsson

    2010-07-01

    Full Text Available The Australasian and South American marsupial mammals, such as kangaroos and opossums, are the closest living relatives to placental mammals, having shared a common ancestor around 130 million years ago. The evolutionary relationships among the seven marsupial orders have, however, so far eluded resolution. In particular, the relationships between the four Australasian and three South American marsupial orders have been intensively debated since the South American order Microbiotheria was taxonomically moved into the group Australidelphia. Australidelphia is significantly supported by both molecular and morphological data and comprises the four Australasian marsupial orders and the South American order Microbiotheria, indicating a complex, ancient, biogeographic history of marsupials. However, the exact phylogenetic position of Microbiotheria within Australidelphia has yet to be resolved using either sequence or morphological data analysis. Here, we provide evidence from newly established and virtually homoplasy-free retroposon insertion markers for the basal relationships among marsupial orders. Fifty-three phylogenetically informative markers were retrieved after in silico and experimental screening of approximately 217,000 retroposon-containing loci from opossum and kangaroo. The four Australasian orders share a single origin with Microbiotheria as their closest sister group, supporting a clear divergence between South American and Australasian marsupials. In addition, the new data place the South American opossums (Didelphimorphia as the first branch of the marsupial tree. The exhaustive computational and experimental evidence provides important insight into the evolution of retroposable elements in the marsupial genome. Placing the retroposon insertion pattern in a paleobiogeographic context indicates a single marsupial migration from South America to Australia. The now firmly established phylogeny can be used to determine the direction of

  14. Experimental testing of exchangeable cutting inserts cutting ability

    OpenAIRE

    Čep, Robert; Janásek, Adam; Čepová, Lenka; Petrů, Jana; Hlavatý, Ivo; Car, Zlatan; Hatala, Michal

    2013-01-01

    The article deals with experimental testing of the cutting ability of exchangeable cutting inserts. Eleven types of exchangeable cutting inserts from five different manufacturers were tested. The tested cutting inserts were of the same shape and were different especially in material and coating types. The main aim was both to select a suitable test for determination of the cutting ability of exchangeable cutting inserts and to design such testing procedure that could make it possible...

  15. Atomistic Galois insertions for flow sensitive integrity

    DEFF Research Database (Denmark)

    Nielson, Flemming; Nielson, Hanne Riis

    2017-01-01

    Several program verification techniques assist in showing that software adheres to the required security policies. Such policies may be sensitive to the flow of execution and the verification may be supported by combinations of type systems and Hoare logics. However, this requires user assistance...... and to obtain full automation we shall explore the over-approximating nature of static analysis. We demonstrate that the use of atomistic Galois insertions constitutes a stable framework in which to obtain sound and fully automatic enforcement of flow sensitive integrity. The framework is illustrated...... on a concurrent language with local storage and polyadic synchronous communication....

  16. Artists's Conception of Cassini Saturn Orbit Insertion

    Science.gov (United States)

    2002-01-01

    This is an artists concept of Cassini during the Saturn Orbit Insertion (SOI) maneuver, just after the main engine has begun firing. The spacecraft is moving out of the plane of the page and to the right (firing to reduce its spacecraft velocity with respect to Saturn) and has just crossed the ring plane.The SOI maneuver, which is approximately 90 minutes long, will allow Cassini to be captured by Saturn's gravity into a five-month orbit.Cassini's close proximity to the planet after the maneuver offers a unique opportunity to observe Saturn and its rings at extremely high resolution.

  17. Reflex sympathetic dystrophy following pacemaker insertion.

    Science.gov (United States)

    Londhey, Vikram A; Singh, Nishant; Kini, Seema

    2011-09-01

    A 55 year old male presented with pain and swelling over dorsum of right hand and small joints, and loss of sweating over right hand since two months. He was a known case of mitral valve prolapse (MVP) with mitral regurgitation and complete heart block for which pacemaker was implanted 1 year back. Bilateral wrist X-ray was suggestive of pronounced demineralization (osteopenia) in the right hand. He was thus diagnosed to have reflex sympathetic dystrophy syndrome (RSDS) considered to be induced by pacemaker insertion. After treatment with amitryptiline and indomethacin his symptoms dramatically improved.

  18. Compiler-assisted static checkpoint insertion

    Science.gov (United States)

    Long, Junsheng; Fuchs, W. K.; Abraham, Jacob A.

    1992-01-01

    This paper describes a compiler-assisted approach for static checkpoint insertion. Instead of fixing the checkpoint location before program execution, a compiler enhanced polling mechanism is utilized to maintain both the desired checkpoint intervals and reproducible checkpoint 1ocations. The technique has been implemented in a GNU CC compiler for Sun 3 and Sun 4 (Sparc) processors. Experiments demonstrate that the approach provides for stable checkpoint intervals and reproducible checkpoint placements with performance overhead comparable to a previously presented compiler assisted dynamic scheme (CATCH) utilizing the system clock.

  19. Intramolecular hydroxycarbene C–H-insertion: The curious case of (o-methoxyphenylhydroxycarbene

    Directory of Open Access Journals (Sweden)

    Dennis Gerbig

    2010-11-01

    Full Text Available The first C–H insertion of a hydroxycarbene species in the gas phase has been observed experimentally by means of high vacuum flash pyrolysis (HVFP and subsequent matrix isolation: (o-Methoxyphenylglyoxylic acid gives non-isolable (o-methoxyphenylhydroxycarbene upon pyrolysis at 600 °C, which rapidly inserts into the methyl C–H bond. The insertion product, 2,3-dihydrobenzofuran-3-ol, was trapped in an excess of Ar at 11 K and characterized by infrared spectroscopy. The insertion process kinetically outruns the alternative [1,2]H-tunneling reaction to o-anisaldehyde, a type of reaction observed for other hydroxycarbenes. Traces of the dehydration product, benzo[b]furan, were also detected. The potential energy hypersurface including the insertion and hydrogen migration processes was computed at the all-electron coupled-cluster level of theory encompassing single and double substitutions and perturbatively included triple excitations [AE-CCSD(T] in conjunction with a correlation-consistent double-ζ basis set (cc-pVDZ by utilizing density functional theory (DFT optimized geometries (M06-2X/cc-pVDZ with zero-point vibrational energy (ZPVE corrections. Exchange of the methoxy for a trifluoromethoxy group successfully prevents insertion and (o-trifluoromethoxybenzaldehyde is produced instead; however, the carbene cannot be observed under these conditions. Thermal decomposition of (o-methoxyphenylglyoxylic acid in refluxing xylenes does not give the insertion product but yields o-anisaldehyde. This unanticipated outcome can be rationalized by protonation of the hydroxycarbene intermediate leading to the tautomeric formyl group. Thermochemical computations at M06-2X/cc-pVDZ in conjunction with a self-consistent solvent reaction field model support this suggested reaction pathway.

  20. Anatomical study and morphometric analyses on the femoral insertions of the posterior cruciate ligament

    Directory of Open Access Journals (Sweden)

    Julio Cesar Gali

    2013-04-01

    Full Text Available PURPOSE: To provide an anatomical and morphometric basis for the femoral insertions of the posterior cruciate ligament (PCL in order to aid in the creation of anatomical femoral tunnels in ligament surgical reconstruction. Study design: laboratory controlled study. MATERIAL AND METHODS: The macroscopic details of the femoral insertions of the PCL's anterolateral (AL and posteromedial (PM bundles were analyzed in 24 cadaver knees. The specimens were photographed with a digital camera and the images obtained were studied using the software ImageJ. The bundles' insertion areas were measured in square millimeters, and the length of the structures and the distances between significant points were measured in millimeters. RESULTS: The PCL's femoral insertion average total area was 87.29 ± 31.42 mm².The mean insertion's areas of the AL and PM bundles were, respectively, 47.13 ± 19.14 and 40.67 ± 16.19 mm². In 95.8% of the examined knees was verified the presence of the medial intercondylar ridge and in 83.3% of the knees was noted the medial bifurcated ridge. The average length of the medial intercondylar ridge was 20.54 ± 2.26 mm and the medial bifurcated ridge's average length was 7.62 ± 2.35 mm. CONCLUSIONS: The AL had a femoral insertion area larger than the PM bundle; these bundles' insertion areas were lower than those previously described in the literature. There were important individual variations related to the area of the bundles in the samples, suggesting that there should be an individual recommendation for anatomical reconstructions of the PCL with single or double femoral tunnels.

  1. Lithium Insertion Chemistry of Some Iron Vanadates

    Energy Technology Data Exchange (ETDEWEB)

    Patoux, Sebastien; Richardson, Thomas J.

    2007-02-02

    Lithium insertion into various iron vanadates has been investigated. Fe{sub 2}V{sub 4}O{sub 13} and Fe{sub 4}(V{sub 2}O{sub 7}){sub 3} {center_dot} 3H{sub 2}O have discharge capacities approaching 200 mAh/g above 2.0 V vs. Li{sup +}/Li. Although the potential profiles change significantly between the first and subsequent discharges, capacity retention is unexpectedly good. Other phases, structurally related to FeVO{sub 4}, containing copper and/or sodium ions were also studied. One of these, {beta}-Cu{sub 3}Fe{sub 4}(VO{sub 4}){sub 6}, reversibly consumes almost 10 moles of electrons per formula unit (ca. 240 mAh g{sup -1}) between 3.6 and 2.0 V vs. Li{sup +}/Li, in a non-classical insertion process. It is proposed that both copper and vanadium are electrochemically active, whereas iron(III) reacts to form LiFe{sup III}O{sub 2}. The capacity of the Cu{sub 3}Fe{sub 4}(VO{sub 4}){sub 6}/Li system is nearly independent of cycling rate, stabilizing after a few cycles at 120-140 mAh g{sup -1}. Iron vanadates exhibit better capacities than their phosphate analogues, whereas the latter display more constant discharge potentials.

  2. Safety analysis for reactivity insertion on ADS

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Marcia S.; Velasquez, Carlos E.; Pereira, Claubia; Veloso, Maria Auxiliadora F.; Costa, Antonella L. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Barros, Graiciany de P. [Comissão Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    In this work, an accelerator driven system (ADS) has been studied to fuel regeneration, partitioning and transmutation using fuel removed from LWR-spent fuel. This spent fuel was reprocessed by GANEX and then spiked with thorium. Monteburns 2.0 (MCNP5/ORIGEN 2.1) code was used to simulate burnup and neutronic parameters of the systems. However, these systems might be interrupted for some technical problems during few days or long periods to perform maintenance of accelerator systems without shutdown the fission system. Therefore, in this work, the aim was to investigate the nuclear fuel evolution in three different cases with reactivity insertions and variations in the functionality of the ADS. The evaluation has been performed for a burnup of 3 years, which are the most dangerous years in case of reactivity insertions. Therefore, in the first case the ADS during its burnup the external source (spallation source) is cutting off from the system several times during the first year of burnup. In the second case, it is simulated the reactor at different power from 0 (shutdown) to 1.5 times the 515MWt. The results shows the safety limits of the ADS for different situation. (author)

  3. Polymeric Biodegradable Stent Insertion in the Esophagus

    Directory of Open Access Journals (Sweden)

    Kai Yang

    2016-04-01

    Full Text Available Esophageal stent insertion has been used as a well-accepted and effective alternative to manage and improve the quality of life for patients diagnosed with esophageal diseases and disorders. Current stents are either permanent or temporary and are fabricated from either metal or plastic. The partially covered self-expanding metal stent (SEMS has a firm anchoring effect and prevent stent migration, however, the hyperplastic tissue reaction cause stent restenosis and make it difficult to remove. A fully covered SEMS and self-expanding plastic stent (SEPS reduced reactive hyperplasia but has a high migration rate. The main advantage that polymeric biodegradable stents (BDSs have over metal or plastic stents is that removal is not require and reduce the need for repeated stent insertion. But the slightly lower radial force of BDS may be its main shortcoming and a post-implant problem. Thus, strengthening support of BDS is a content of the research in the future. BDSs are often temporarily effective in esophageal stricture to relieve dysphagia. In the future, it can be expect that biodegradable drug-eluting stents (DES will be available to treat benign esophageal stricture, perforations or leaks with additional use as palliative modalities for treating malignant esophageal stricture, as the bridge to surgery or to maintain luminal patency during neoadjuvant chemoradiation.

  4. A piezoelectric vibration-based syringe for reducing insertion force

    Science.gov (United States)

    Huang, Y. C.; Tsai, M. C.; Lin, C. H.

    2012-12-01

    Puncturing of the human skin with a needle is perhaps the most common invasive medical procedure. Clinical studies have revealed that tissue deformation and needle deflection are the primary problem for needle misplacement in percutaneous procedures. To avoid this, various techniques for reducing insertion forces during needle insertion have been considered. This paper presents a piezoelectric vibration-based syringe to reduce insertion force. AC power was applied to the piezoelectric elements to vibrate the needle with high frequency and thereby reduce the friction and cutting forces between the needle and tissue. Vibration mode shapes of the needle were observed by finite element analysis and verified by experimental results. Effects of reducing insertion force via the vibrating needle were also confirmed by inserting the needle into the porcine tissues. The proposed syringe, which minimizes the insertion force and overcomes limitations of needle materials, can be widely utilized in robot-assisted needle insertion systems.

  5. Strain of bone-implant interface and insertion torque regarding different miniscrew thread designs using an artificial bone model.

    Science.gov (United States)

    Cha, Jung-Yul; Hwang, Chung-Ju; Kwon, Sung Hwang; Jung, Han-Sung; Kim, Kwang-Mahn; Yu, Hyung Seog

    2015-06-01

    To evaluate the initial stability of dual-thread miniscrews by analyzing the strain at the bone-implant interface and insertion torque during implantation in artificial bone models with different cortical bone thicknesses. Insertion torque, and strain, measured with a five-element strain gauge in 1.0, 1.5, and 2.0-mm artificial cortical bone, during insertion of single- (OAS-T1507) and dual-thread (MPlant-U3) type self-drilling miniscrews were assessed. Both dual- and single-thread miniscrews showed greater than 7790 μstrain for all cortical bone thicknesses, and dual-thread miniscrews reached up to 19580 μstrain in 2.00 m m cortical bone. The strain of dual-thread miniscrews increased with increasing cortical bone thicknesses of 1.0-2.0mm. For single-thread miniscrews, the maximum insertion torque was relatively constant, but maximum insertion torque increased significantly in dual-thread groups with increasing cortical bone thicknesses (P bone thicknesses was significantly lower with single- than dual-thread types (P bone remodelling limit at the bone-implant interface in thick cortical bone layers. © The Author 2014. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  6. Synthesis and insertion chemistry of mixed tether uranium metallocene complexes.

    Science.gov (United States)

    Siladke, Nathan A; LeDuc, Jennifer; Ziller, Joseph W; Evans, William J

    2012-11-12

    The synthesis of mixed tethered alkyl uranium metallocenes has been investigated by examining the reactivity of the bis(tethered alkyl) metallocene [(η(5)-C(5)Me(4)SiMe(2)CH(2)-κC)(2)U] (1) with substrates that react with only one of the U-C linkages. The effect of these mixed tether coordination environments on the reactivity of the remaining U-C bond has been studied by using CO insertion chemistry. One equivalent of azidoadamantane (AdN(3)) reacts with 1 to yield the mixed tethered alkyl triazenido complex [(η(5)-C(5)Me(4)SiMe(2)CH(2)-κC)U(η(5)-C(5)Me(4)SiMe(2)-CH(2)NNN-Ad-κ(2)N(1,3))]. Similarly, a single equivalent of CS(2) reacts with 1 to form the mixed tethered alkyl dithiocarboxylate complex [(η(5)-C(5)Me(4)SiMe(2)CH(2)-κC)U(η(5)-C(5)Me(4)SiMe(2)-CH(2)C(S)(2)-κ(2)S,S')], a reaction that constitutes the first example of CS(2) insertion into a U(4+)-C bond. Complex 1 reacts with one equivalent of pyridine N-oxide by C-H bond activation of the pyridine ring to form a mixed tethered alkyl cyclometalated pyridine N-oxide complex [(η(5)-C(5)Me(4)SiMe(2)CH(2)-κC)(η(5)-C(5)Me(4)SiMe(3))U(C(6)H(4)NO-κ(2)C,O)]. The remaining (η(5)-C(5)Me(4)SiMe(2)CH(2)-κC)(2-) ligand in each of these mixed tethered species show reactivity towards CO and tethered enolate ligands form by insertion. Subsequent rearrangement have been identified in [(η(5)-C(5)Me(4)SiMe(3))U(C(5)H(4)NO-κ(2)C,O)(η(5)-C(5)Me(4)SiMe(2)C(=CH(2))O-κO)] and [(η(5)-C(5)Me(4)SiMe(2)CH(2)NNN-Ad-κ(2)N(1,3))U(η(5)-C(5)Me(4)SiMe(2)C(=CH(2))O-κO)]. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Synthesis and insertion chemistry of mixed tether uranium metallocene complexes

    International Nuclear Information System (INIS)

    Siladke, Nathan A.; LeDuc, Jennifer; Ziller, Joseph W.; Evans, William J.

    2012-01-01

    The synthesis of mixed tethered alkyl uranium metallocenes has been investigated by examining the reactivity of the bis(tethered alkyl) metallocene [(η 5 -C 5 Me 4 SiMe 2 CH 2 -κC) 2 U] (1) with substrates that react with only one of the U-C linkages. The effect of these mixed tether coordination environments on the reactivity of the remaining U-C bond has been studied by using CO insertion chemistry. One equivalent of azidoadamantane (AdN 3 ) reacts with 1 to yield the mixed tethered alkyl triazenido complex [(η 5 -C 5 Me 4 SiMe 2 CH 2 -κC)U(η 5 -C 5 Me 4 SiMe 2 -CH 2 NNN-Ad-κ 2 N 1,3 )]. Similarly, a single equivalent of CS 2 reacts with 1 to form the mixed tethered alkyl dithiocarboxylate complex [(η 5 -C 5 Me 4 SiMe 2 CH 2 -κC)U(η 5 -C 5 Me 4 SiMe 2 - CH 2 C(S) 2 -κ 2 S,S ' )], a reaction that constitutes the first example of CS 2 insertion into a U 4+ -C bond. Complex 1 reacts with one equivalent of pyridine N-oxide by C-H bond activation of the pyridine ring to form a mixed tethered alkyl cyclometalated pyridine N-oxide complex [(η 5 -C 5 Me 4 SiMe 2 CH 2 -κC)(η 5 -C 5 Me 4 SiMe 3 )U(C 6 H 4 NO-κ 2 C,O)]. The remaining (η 5 -C 5 Me 4 SiMe 2 CH 2 -κC) 2- ligand in each of these mixed tethered species show reactivity towards CO and tethered enolate ligands form by insertion. Subsequent rearrangement have been identified in [(η 5 -C 5 Me 4 SiMe 3 )U(C 5 H 4 NO-κ 2 C,O)(η 5 -C 5 Me 4 SiMe 2 C(=CH 2 )O- κO)] and [(η 5 -C 5 Me 4 SiMe 2 CH 2 NNN-Ad-κ 2 N 1,3 )U(η 5 -C 5 Me 4 SiMe 2 C(=CH 2 )O-κO)]. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  8. Accuracy of computer-assisted implant placement with insertion templates

    Science.gov (United States)

    Naziri, Eleni; Schramm, Alexander; Wilde, Frank

    2016-01-01

    Objectives: The purpose of this study was to assess the accuracy of computer-assisted implant insertion based on computed tomography and template-guided implant placement. Material and methods: A total of 246 implants were placed with the aid of 3D-based transfer templates in 181 consecutive partially edentulous patients. Five groups were formed on the basis of different implant systems, surgical protocols and guide sleeves. After virtual implant planning with the CoDiagnostiX Software, surgical guides were fabricated in a dental laboratory. After implant insertion, the actual implant position was registered intraoperatively and transferred to a model cast. Deviations between the preoperative plan and postoperative implant position were measured in a follow-up computed tomography of the patient’s model casts and image fusion with the preoperative computed tomography. Results: The median deviation between preoperative plan and postoperative implant position was 1.0 mm at the implant shoulder and 1.4 mm at the implant apex. The median angular deviation was 3.6º. There were significantly smaller angular deviations (P=0.000) and significantly lower deviations at the apex (P=0.008) in implants placed for a single-tooth restoration than in those placed at a free-end dental arch. The location of the implant, whether in the upper or lower jaw, did not significantly affect deviations. Increasing implant length had a significant negative influence on deviations from the planned implant position. There was only one significant difference between two out of the five implant systems used. Conclusion: The data of this clinical study demonstrate the accuracy and predictable implant placement when using laboratory-fabricated surgical guides based on computed tomography. PMID:27274440

  9. Insertion Device Upgrade Plans at the NSLS

    CERN Document Server

    Tanabe, Toshiya; Harder, David; Lehecka, Michael; Rakowsky, George; Skaritka, John

    2005-01-01

    This paper describes plans to upgrade insertion devices at the National Synchrotron Light Source (NSLS), Brookhaven National Laboratory, U.S.A. The aging wiggler (W80) at X25 is being replaced by a 1 m long in-vacuum mini-gap undulator (MGU-18) optimized for a dedicated macromolecular crystallography program. A new, 1/3 m long, in-vacuum undulator (MGU-13.5), will be installed between a pair of RF cavities at X9, and will serve a new beamline dedicated for small angle x-ray scattering (SAXS). Both MGU’s will have provision for cryocooling the NdFeB hybrid arrays to 150K to raise the field and K-value and to obtain better spectral coverage. Design issues of the devices and other considerations, especially magnetic measurement methods in low temperature will be discussed.

  10. Hand-actuated spring clip insertion tool

    International Nuclear Information System (INIS)

    Cuba, G.W.

    1993-01-01

    A hand-actuated insertion tool includes a handle assembly, an elongated hollow tubular outer support tube, an elongated inner pull rod, and a coupling arrangement. The handle assembly has a first handle member and a second handle member pivoted to a member for movement between unactuated and actuated positions. The tube is attached in a fixed relation to a handle member. The rod is mounted within the tube for sliding movement relative thereto between home and retracted positions. The coupling arrangement pivotally connects the rod to the second handle member such that the rod will undergo sliding movement from the home position to the retracted positions relative to the tube as the second handle member is moved from the unactuated position to the actuated position adjacent to the first handle member. (author)

  11. Impact of Orthodontic Decompensation on Bone Insertion

    Science.gov (United States)

    Guedes, Fabio Pinto; Capelozza Filho, Leopoldino; Garib, Daniela Gamba; Nary Filho, Hugo; Borgo, Evandro José; Cardoso, Mauricio de Almeida

    2014-01-01

    There has always been concern in determining the relationship between orthodontic tooth movement and the consequent biological costs to the periodontium and tooth root. The possibility of evaluating the tooth and bone morphology by CBCT allows more accurate analysis of qualitative and quantitative aspects of these processes. This paper presents a case report of a 20-year-old male patient with Class III malocclusion and hyperdivergent facial pattern, who was surgically treated. A significant amount of labial movement of mandibular incisors was performed during orthodontic treatment before surgery. CBCT was used for evaluation of buccal and lingual bone plates before and after tooth decompensation. The changes in the bone insertion level of maxillary and mandibular incisors in the present case encourage a reflection on the treatment protocol in individuals with dentoskeletal discrepancies. PMID:25436157

  12. Impact of Orthodontic Decompensation on Bone Insertion

    Directory of Open Access Journals (Sweden)

    Fabio Pinto Guedes

    2014-01-01

    Full Text Available There has always been concern in determining the relationship between orthodontic tooth movement and the consequent biological costs to the periodontium and tooth root. The possibility of evaluating the tooth and bone morphology by CBCT allows more accurate analysis of qualitative and quantitative aspects of these processes. This paper presents a case report of a 20-year-old male patient with Class III malocclusion and hyperdivergent facial pattern, who was surgically treated. A significant amount of labial movement of mandibular incisors was performed during orthodontic treatment before surgery. CBCT was used for evaluation of buccal and lingual bone plates before and after tooth decompensation. The changes in the bone insertion level of maxillary and mandibular incisors in the present case encourage a reflection on the treatment protocol in individuals with dentoskeletal discrepancies.

  13. Quench Performance of the LHC Insertion Magnets

    CERN Document Server

    Lasheras, N C; Siemko, A; Ostojic, R; Kirby, G

    2009-01-01

    After final installation in the LHC tunnel, the MQM and MQY quadrupole magnets of the LHC insertions are now being commissioned to their nominal currents. These two types of magnets operate at 1.9 K and 4.5 K and with nominal currents ranging from 3600 A to 5390 A. From the very first acceptance tests of the bare magnets coming from the manufacturers, they have been powered using different cycles, in different configurations, at different temperatures and in different tests facilities. In this paper we present the global results of these powering tests. We aim at separating common from individual features of these groups of magnets. Temperature dependence of the training, temperature margin, and ultimate current can be extracted from these tests. As these magnets are used to match the optics and the dispersion in the machine, the projected ultimate current at which they can be operated is critical in view of operation of LHC.

  14. An update on insertable cardiac monitors

    DEFF Research Database (Denmark)

    Olsen, Flemming J; Biering-Sørensen, Tor; Krieger, Derk W

    2015-01-01

    Continuous cardiac rhythm monitoring has undergone compelling progress over the past decades. Cardiac monitoring has emerged from 12-lead electrocardiograms being performed at the discretion of the treating physician to in-hospital telemetry, Holter monitoring, prolonged external event monitoring...... turning point in the field of arrhythmia management. However, their role in the detection of paroxysmal atrial fibrillation after cryptogenic strokes has yet to evolve. This will be the main focus of this review. Issues surrounding patient selection, clinical relevance and determination of cost......-effectiveness for prolonged cardiac monitoring require further studies. Furthermore, insertable cardiac monitoring has not only the potential to augment diagnostic capabilities but also to improve the management of paroxysmal atrial fibrillation....

  15. COMPLICATIONS NASOGASTRIC TUBE INSERTION AND TREATMENT

    Directory of Open Access Journals (Sweden)

    Dwi Kresnawati

    2013-12-01

    Full Text Available Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 Insertion of a nasogastric tube (NGT is an invasive procedure that is often done by increasing medical emergency. There are two indications of this procedure,the indications are for diagnostic and therapeutic interest mainly to access and evaluate the nutritional content of the stomach for patients with suspected gastrointestinal bleeding. Although nasogastric tube insertion simpler, easier and safer than with a pipe orogastrik, but complications can occur during installation such as malposition of NGT, epistaxis, mucosal trauma, aspiration pneumonia, hypoxemia and pneumothorak. So the importance of knowledge, skills, and how treatment for complications arising prevents one way to ensure the proper placement of NGT. /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;}

  16. Increasing prion propensity by hydrophobic insertion.

    Directory of Open Access Journals (Sweden)

    Aaron C Gonzalez Nelson

    Full Text Available Prion formation involves the conversion of proteins from a soluble form into an infectious amyloid form. Most yeast prion proteins contain glutamine/asparagine-rich regions that are responsible for prion aggregation. Prion formation by these domains is driven primarily by amino acid composition, not primary sequence, yet there is a surprising disconnect between the amino acids thought to have the highest aggregation propensity and those that are actually found in yeast prion domains. Specifically, a recent mutagenic screen suggested that both aromatic and non-aromatic hydrophobic residues strongly promote prion formation. However, while aromatic residues are common in yeast prion domains, non-aromatic hydrophobic residues are strongly under-represented. Here, we directly test the effects of hydrophobic and aromatic residues on prion formation. Remarkably, we found that insertion of as few as two hydrophobic residues resulted in a multiple orders-of-magnitude increase in prion formation, and significant acceleration of in vitro amyloid formation. Thus, insertion or deletion of hydrophobic residues provides a simple tool to control the prion activity of a protein. These data, combined with bioinformatics analysis, suggest a limit on the number of strongly prion-promoting residues tolerated in glutamine/asparagine-rich domains. This limit may explain the under-representation of non-aromatic hydrophobic residues in yeast prion domains. Prion activity requires not only that a protein be able to form prion fibers, but also that these fibers be cleaved to generate new independently-segregating aggregates to offset dilution by cell division. Recent studies suggest that aromatic residues, but not non-aromatic hydrophobic residues, support the fiber cleavage step. Therefore, we propose that while both aromatic and non-aromatic hydrophobic residues promote prion formation, aromatic residues are favored in yeast prion domains because they serve a dual

  17. The NF1 gene contains hotspots for L1 endonuclease-dependent de novo insertion.

    Directory of Open Access Journals (Sweden)

    Katharina Wimmer

    2011-11-01

    Full Text Available Long interspersed (L1 and Alu elements are actively amplified in the human genome through retrotransposition of their RNA intermediates by the -100 still retrotranspositionally fully competent L1 elements. Retrotransposition can cause inherited disease if such an element is inserted near or within a functional gene. Using direct cDNA sequencing as the primary assay for comprehensive NF1 mutation analysis, we uncovered in 18 unrelated index patients splicing alterations not readily explained at the genomic level by an underlying point-mutation or deletion. Improved PCR protocols avoiding allelic drop-out of the mutant alleles uncovered insertions of fourteen Alu elements, three L1 elements, and one poly(T stretch to cause these splicing defects. Taken together, the 18 pathogenic L1 endonuclease-mediated de novo insertions represent the largest number of this type of mutations characterized in a single human gene. Our findings show that retrotransposon insertions account for as many as -0.4% of all NF1 mutations. Since altered splicing was the main effect of the inserted elements, the current finding was facilitated by the use of RNA-based mutation analysis protocols, resulting in improved detection compared to gDNA-based approaches. Six different insertions clustered in a relatively small 1.5-kb region (NF1 exons 21(16-23(18 within the 280-kb NF1 gene. Furthermore, three different specific integration sites, one of them located in this cluster region, were each used twice, i.e. NM_000267.3(NF1:c.1642-1_1642 in intron 14(10c, NM_000267.3(NF1:c.2835_2836 in exon 21(16, and NM_000267.3(NF1:c.4319_4320 in exon 33(25. Identification of three loci that each served twice as integration site for independent retrotransposition events as well as 1.5-kb cluster region harboring six independent insertions supports the notion of non-random insertion of retrotransposons in the human genome. Currently, little is known about which features make sites

  18. Declines in stimulated striatal dopamine release over the first 32 h following microdialysis probe insertion: generalization across releasing mechanisms.

    Science.gov (United States)

    Holson, R R; Gazzara, R A; Gough, B

    1998-10-19

    In a recent paper [R.R. Holson, J.F. Bowyer, P. Clausing, B. Gough, Methamphetamine-stimulated striatal dopamine release declines rapidly over time following microdialysis probe insertion, Brain Res. 739 (1996) 301-307] we reported that methamphetamine-stimulated striatal dopamine release declined rapidly over the first eight hours following microdialysis probe insertion. This decline was strictly a function of time post-probe implantation, and not due to tolerance or desensitization. To further examine this phenomenon, we subjected rats to three brief pulses of several DA-releasing compounds at 2, 4 and 6 h post-probe insertion, and compared these results to those caused by a single pulse 6 h post-insertion, or in some cases to pulses given more than 24 h post-insertion. We found that when buproprion, a dopamine reuptake blocker, was infused briefly into the striatum via the microdialysis probe, there was a pronounced drop in the amount of dopamine released at 6 h vs. 2 h post-insertion; this drop was not due to repeated exposure, since dopamine release at 6 h post-insertion was the same for a single pulse, or when preceded by two earlier pulses. Twenty-four hours later, buproprion-stimulated dopamine release was still lower, but did not appear to drop further thereafter. Potassium-stimulated dopamine release, on the other hand, dropped rapidly over the first 8 h post-insertion, and this decline continued throughout the 24-32 h interval post-insertion. Similarly, a single i.p. injection of 0.5 mg/kg haloperidol released three times as much dopamine when given two compared to six hours post-implantation. Both bupropion- and potassium-stimulated dopamine release were accompanied by declines in extracellular DOPAC concentrations, and these declines were the same 2 or 26 h post-insertion. In contrast, haloperidol exposure increased extracellular DOPAC, and this haloperidol-stimulated DOPAC increase was also greatly attenuated at 6 compared to 2 h post-insertion. We

  19. HangOut: generating clean PSI-BLAST profiles for domains with long insertions.

    Science.gov (United States)

    Kim, Bong-Hyun; Cong, Qian; Grishin, Nick V

    2010-06-15

    Profile-based similarity search is an essential step in structure-function studies of proteins. However, inclusion of non-homologous sequence segments into a profile causes its corruption and results in false positives. Profile corruption is common in multidomain proteins, and single domains with long insertions are a significant source of errors. We developed a procedure (HangOut) that, for a single domain with specified insertion position, cleans erroneously extended PSI-BLAST alignments to generate better profiles. HangOut is implemented in Python 2.3 and runs on all Unix-compatible platforms. The source code is available under the GNU GPL license at http://prodata.swmed.edu/HangOut/. Supplementary data are available at Bioinformatics online.

  20. An Assessment of Radiologically Inserted Transoral and Transgastric Gastroduodenal Stents to Treat Malignant Gastric Outlet Obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Bethany H. T., E-mail: bmiller@doctors.org.uk [Lancashire Teaching Hospitals NHS Foundation Trust, Royal Preston Hospital, Department of Upper Gastrointestinal Surgery (United Kingdom); Griffiths, Ewen A., E-mail: Eagriffiths@doctors.org.uk [The New Queen Elizabeth Hospital, Department of Upper Gastrointestinal Surgery (United Kingdom); Pursnani, Kishore G., E-mail: Kish.Pursnani@lthtr.nhs.uk; Ward, Jeremy B., E-mail: Jeremy.Ward@lthtr.nhs.uk [Lancashire Teaching Hospitals NHS Foundation Trust, Royal Preston Hospital, Department of Upper Gastrointestinal Surgery (United Kingdom); Stockwell, Robert C., E-mail: Robert.Stockwell@lthtr.nhs.uk [Lancashire Teaching Hospitals NHS Foundation Trust, Chorley and South Ribble Hospital, Department of Radiology (United Kingdom)

    2013-12-15

    IntroductionSelf-expanding metallic stents (SEMS) are used to palliate malignant gastric outlet obstruction (GOO) and are useful in patients with limited life expectancy or severe medical comorbidity, which would preclude surgery. Stenting can be performed transorally or by a percutaneous transgastric technique. Our goal was to review the outcome of patients who underwent radiological SEMS insertion performed by a single consultant interventional radiologist. Methods: Patients were identified from a prospectively collected database held by one consultant radiologist. Data were retrieved from radiological reports, multidisciplinary team meetings, and the patients' case notes. Univariate survival analysis was performed. Results: Between December 2000 and January 2011, 100 patients (63 males, 37 females) had 110 gastroduodenal stenting procedures. Median age was 73 (range 39-89) years. SEMS were inserted transorally (n = 66) or transgastrically (n = 44). Site of obstruction was the stomach (n = 37), duodenum (n = 50), gastric pull-up (n = 10), or gastroenterostomy (n = 13). Seven patients required biliary stents. Technical success was 86.4 %: 83.3 % for transoral insertion, 90.9 % for transgastric insertion. Eleven patients developed complications. Median GOO severity score: 1 pre-stenting, 2 post-stenting (p = 0.0001). Median survival was 54 (range 1-624) days. Post-stenting GOO severity score was predictive of survival (p = 0.0001). Conclusions: The technical success rate for insertion of palliative SEMS is high. Insertional technique can be tailored to the individual depending on the location of the tumor and whether it is possible to access the stomach percutaneously. Patients who have successful stenting and return to eating a soft/normal diet have a statistically significant increase in survival.

  1. An assessment of radiologically inserted transoral and transgastric gastroduodenal stents to treat malignant gastric outlet obstruction.

    Science.gov (United States)

    Miller, Bethany H T; Griffiths, Ewen A; Pursnani, Kishore G; Ward, Jeremy B; Stockwell, Robert C

    2013-12-01

    Self-expanding metallic stents (SEMS) are used to palliate malignant gastric outlet obstruction (GOO) and are useful in patients with limited life expectancy or severe medical comorbidity, which would preclude surgery. Stenting can be performed transorally or by a percutaneous transgastric technique. Our goal was to review the outcome of patients who underwent radiological SEMS insertion performed by a single consultant interventional radiologist. Patients were identified from a prospectively collected database held by one consultant radiologist. Data were retrieved from radiological reports, multidisciplinary team meetings, and the patients' case notes. Univariate survival analysis was performed. Between December 2000 and January 2011, 100 patients (63 males, 37 females) had 110 gastroduodenal stenting procedures. Median age was 73 (range 39-89) years. SEMS were inserted transorally (n = 66) or transgastrically (n = 44). Site of obstruction was the stomach (n = 37), duodenum (n = 50), gastric pull-up (n = 10), or gastroenterostomy (n = 13). Seven patients required biliary stents. Technical success was 86.4 %: 83.3 % for transoral insertion, 90.9 % for transgastric insertion. Eleven patients developed complications. Median GOO severity score: 1 pre-stenting, 2 post-stenting (p = 0.0001). Median survival was 54 (range 1-624) days. Post-stenting GOO severity score was predictive of survival (p = 0.0001). The technical success rate for insertion of palliative SEMS is high. Insertional technique can be tailored to the individual depending on the location of the tumor and whether it is possible to access the stomach percutaneously. Patients who have successful stenting and return to eating a soft/normal diet have a statistically significant increase in survival.

  2. Lateral Intercondylar Ridge: Is it a reliable landmark for femoral ACL insertion?: An anatomical study.

    Science.gov (United States)

    Bhattacharyya, Rahul; Ker, Andrew; Fogg, Quentin; Spencer, Simon J; Joseph, Jibu

    2018-02-01

    Incorrect femoral tunnel placement is the most common cause of graft failure during Anterior Cruciate Ligament (ACL) Reconstruction. A reliable landmark can minimize errors. To identify whether the Lateral Intercondylar Ridge (LIR) is a consistent anatomical structure and define its relationship with the femoral ACL insertion. Phase 1: we studied 23 femoral dry bone specimens macroscopically. Using a digital microscribe, the medial surface of the lateral femoral condyle was reconstructed (3D) to evaluate whether there was an identifiable bony ridge. Phase 2: 7 cadaveric specimens with intact soft tissues were dissected to identify the femoral ACL insertion. A 3D reconstruction of the femoral ACL insertion and the surface allowed us to define the relationship between the LIR and the ACL insertion. All specimens had a defined LIR on the medial surface of the lateral femoral condyle. The ridge was consistently located just anterior to the femoral ACL insertion. The ACL footprint was present in the depression between the ridge and the Inferior Articular Cartilage Margin (IACM). The mean distance from the midpoint of the IACM to the LIR was 10.1 mm. This is the first study to use the microscribe to digitally reconstruct the medial surface of the lateral femoral condyle. It shows that the LIR is a consistent anatomical structure that defines the anterior margin of the femoral ACL insertion, which guides femoral tunnel placement. Our findings support the ruler technique, which is a commonly used method for anatomic single bundle ACL reconstruction. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  3. Insertion of laryngeal mask airway does not increase the intraocular pressure in children with glaucoma.

    Science.gov (United States)

    Bhardwaj, Neerja; Yaddanapudi, Sandhya; Singh, Swati; Pandav, Surinder S

    2011-10-01

    It is hypothesized that in children with glaucoma, the insertion of laryngeal mask airway (LMA) will cause lesser rise in intraocular pressure (IOP) than tracheal tube (TT). To compare the IOP response to LMA and TT insertion in children with glaucoma. A prospective, randomized, single-blind study was conducted in 30 glaucomatous ASA-1 children, aged 1-10 years scheduled to undergo trabeculectomy. Anesthesia was induced with halothane and maintained for 5 min with 1 MAC of halothane after administering atracurium 0.5 mg·kg(-1) following which LMA or TT was introduced. IOP was measured in both the eyes before and after insertion of airway device for 5 min. The IOP increased significantly from 27.3 ± 5.2 to 31.2 ± 5.4 mmHg (P insertion of LMA. The IOP was significantly higher in group TT compared to group LMA at 2 min (P = 0.004) and 5 min (P = 0.01) after the device insertion. The heart rate (HR) increased significantly after tracheal intubation and returned to baseline 4 min after intubation. The HR increase was significantly more in TT group compared to LMA group at all times of observation. Both systolic blood pressure (SBP; P = 0.01) and diastolic blood pressure (DBP; P = 0.02) showed an increase at 1 min in children in group TT. Insertion of LMA in glaucomatous children is not associated with an increased IOP response or cardiovascular changes. © 2011 Blackwell Publishing Ltd.

  4. An Assessment of Radiologically Inserted Transoral and Transgastric Gastroduodenal Stents to Treat Malignant Gastric Outlet Obstruction

    International Nuclear Information System (INIS)

    Miller, Bethany H. T.; Griffiths, Ewen A.; Pursnani, Kishore G.; Ward, Jeremy B.; Stockwell, Robert C.

    2013-01-01

    IntroductionSelf-expanding metallic stents (SEMS) are used to palliate malignant gastric outlet obstruction (GOO) and are useful in patients with limited life expectancy or severe medical comorbidity, which would preclude surgery. Stenting can be performed transorally or by a percutaneous transgastric technique. Our goal was to review the outcome of patients who underwent radiological SEMS insertion performed by a single consultant interventional radiologist. Methods: Patients were identified from a prospectively collected database held by one consultant radiologist. Data were retrieved from radiological reports, multidisciplinary team meetings, and the patients’ case notes. Univariate survival analysis was performed. Results: Between December 2000 and January 2011, 100 patients (63 males, 37 females) had 110 gastroduodenal stenting procedures. Median age was 73 (range 39–89) years. SEMS were inserted transorally (n = 66) or transgastrically (n = 44). Site of obstruction was the stomach (n = 37), duodenum (n = 50), gastric pull-up (n = 10), or gastroenterostomy (n = 13). Seven patients required biliary stents. Technical success was 86.4 %: 83.3 % for transoral insertion, 90.9 % for transgastric insertion. Eleven patients developed complications. Median GOO severity score: 1 pre-stenting, 2 post-stenting (p = 0.0001). Median survival was 54 (range 1–624) days. Post-stenting GOO severity score was predictive of survival (p = 0.0001). Conclusions: The technical success rate for insertion of palliative SEMS is high. Insertional technique can be tailored to the individual depending on the location of the tumor and whether it is possible to access the stomach percutaneously. Patients who have successful stenting and return to eating a soft/normal diet have a statistically significant increase in survival

  5. Evaluation of a New Ultrasonic Insert for Prosthodontic Preparation.

    Science.gov (United States)

    Baldi, Domenico; Menini, Maria; Colombo, Jacopo; Lertora, Enrico; Pera, Paolo

    This paper describes a new ultrasonic instrument (tipholder DB1 with crown prep tip inserts) designed to optimize prosthodontic margin repositioning and finishing. The insert movement was assessed, and it was demonstrated that tipholder DB1 provides its inserts with an elliptical-like movement, making the entire insert surface able to cut. Then, 20 extracted teeth were prepared using tipholder DB1, sonic instruments, and traditional drills. Dental surface roughness produced using each of the three tools was measured using a roughness tester. Results were compared using univariate analysis of variance and Bonferroni post hoc test. The roughness produced using tipholder DB1 with crown prep insert presented no statistically significant differences compared to the roughness produced using sonic instruments and traditional drills. Tipholder DB1 with crown prep inserts is a promising treatment for margin repositioning and finishing.

  6. Does a novel method of PICC insertion improve safety?

    Science.gov (United States)

    Caparas, Jona; Hu, Jian Ping; Hung, Hwei-San

    2014-05-01

    Placing a central venous access device via the internal jugular or subclavian vein entails significant risks to both patient and healthcare worker. The purpose of this randomized, prospective study was to determine whether the accelerated Seldinger technique (AST) offers significant safety advantages over the modified Seldinger technique (MST) for peripherally inserted central catheter insertion. Patients were randomly assigned to undergo introducer sheath insertion by means of either MST or AST. Primary outcome measures included time to completion of introducer sheath insertion, estimated blood loss, and success rate. Secondary outcome measures included vessel-to-air exposure events and unprotected sharps exposure. While both insertion methods proved equivalent for successful vessel cannulation, AST was significantly faster (P = 0.0048) and resulted in less blood loss (P = 0.0295) than MST. Additionally, AST resulted in significantly fewer vessel-to-air exposure events (P PICC peelable introducer sheath insertion.

  7. Linear motion device and method for inserting and withdrawing control rods

    Science.gov (United States)

    Smith, J.E.

    Disclosed is a linear motion device and more specifically a control rod drive mechanism (CRDM) for inserting and withdrawing control rods into a reactor core. The CRDM and method disclosed is capable of independently and sequentially positioning two sets of control rods with a single motor stator and rotor. The CRDM disclosed can control more than one control rod lead screw without incurring a substantial increase in the size of the mechanism.

  8. The APOB insertion/deletion polymorphism (rs17240441) influences postprandial lipaemia in healthy adults

    OpenAIRE

    Vimaleswaran, Karani Santhanakrishnan; Minihane, Anne M; Li, Yue; Gill, Rosalyn; Lovegrove, Julie A; Williams, Christine M; Jackson, Kim G

    2015-01-01

    BACKGROUND: \\ud Apolipoprotein (apo)B is the structural apoprotein of intestinally- and liver- derived lipoproteins and plays an important role in the transport of triacylglycerol (TAG) and cholesterol. Previous studies have examined the association between the APOB insertion/deletion (ins/del) polymorphism (rs17240441) and postprandial lipaemia in response to a single meal; however the findings have been inconsistent with studies often underpowered to detect genotype-lipaemia associations, f...

  9. Collimator design for a multipinhole brain SPECT insert for MRI

    Energy Technology Data Exchange (ETDEWEB)

    Van Audenhaege, Karen; Van Holen, Roel; Vanhove, Christian; Vandenberghe, Stefaan [Department of Electronics and Information Systems, Ghent University-iMinds Medical IT, MEDISIP-IBiTech, De Pintelaan 185 block B/5, Ghent B-9000 (Belgium)

    2015-11-15

    Purpose: Brain single photon emission computed tomography (SPECT) imaging is an important clinical tool, with unique tracers for studying neurological diseases. Nowadays, most commercial SPECT systems are combined with x-ray computed tomography (CT) in so-called SPECT/CT systems to obtain an anatomical background for the functional information. However, while CT images have a high spatial resolution, they have a low soft-tissue contrast, which is an important disadvantage for brain imaging. Magnetic resonance imaging (MRI), on the other hand, has a very high soft-tissue contrast and does not involve extra ionizing radiation. Therefore, the authors designed a brain SPECT insert that can operate inside a clinical MRI. Methods: The authors designed and simulated a compact stationary multipinhole SPECT insert based on digital silicon photomultiplier detector modules, which have shown to be MR-compatible and have an excellent intrinsic resolution (0.5 mm) when combined with a monolithic 2 mm thick LYSO crystal. First, the authors optimized the different parameters of the SPECT system to maximize sensitivity for a given target resolution of 7.2 mm in the center of the field-of-view, given the spatial constraints of the MR system. Second, the authors performed noiseless simulations of two multipinhole configurations to evaluate sampling and reconstructed resolution. Finally, the authors performed Monte Carlo simulations and compared the SPECT insert with a clinical system with ultrahigh-resolution (UHR) fan beam collimators, based on contrast-to-noise ratio and a visual comparison of a Hoffman phantom with a 9 mm cold lesion. Results: The optimization resulted in a stationary multipinhole system with a collimator radius of 150.2 mm and a detector radius of 172.67 mm, which corresponds to four rings of 34 diSPM detector modules. This allows the authors to include eight rings of 24 pinholes, which results in a system volume sensitivity of 395 cps/MBq. Noiseless simulations

  10. Insertion torque versus mechanical resistance of mini- implants inserted in different cortical thickness

    Directory of Open Access Journals (Sweden)

    Renata de Faria Santos

    2014-06-01

    Full Text Available OBJECTIVE: This study aimed to measure insertion torque, tip mechanical resistance to fracture and transmucosal neck of mini-implants (MI (Conexão Sistemas de PróteseT, as well as to analyze surface morphology. METHODS: Mechanical tests were carried out to measure the insertion torque of MIs in different cortical thicknesses, and tip mechanical resistance to fracture as well as transmucosal neck of MIs. Surface morphology was assessed by scanning electron microscopy (SEM before and after the mechanical tests. RESULTS: Values of mechanical resistance to fracture (22.14 N.cm and 54.95 N.cm were higher and statistically different (P 0.05 to torsional fracture in the tip of MI (22.14 N.cm when 3 mm cortical thickness (16.11 N.cm and dense bone (23.95 N.cm were used. Torsional fracture of the transmucosal neck (54.95 N.cm was higher and statistically different (P < 0.05 from insertion torsional strength in all tested situations. SEM analysis showed that the MIs had the same smooth surface when received from the manufacturer and after the mechanical tests were performed. Additionally, no significant marks resulting from the manufacturing process were observed. CONCLUSION: All mini-implants tested presented adequate surface morphology. The resistance of mini-implants to fracture safely allows placement in 1 and 2-mm cortical thickness. However, in 3-mm cortical thickness and dense bones, pre-drilling with a bur is recommended before insertion.

  11. Nasogastric tubes. 1: Insertion technique and confirming the correct position.

    Science.gov (United States)

    Durai, Rajaraman; Venkatraman, Ramya; Ng, Philip C H

    This is the first in a two-part unit on nasogastric tube management. It discusses the indications, patient preparation, insertion technique and various methods of confirming the tube's position. According to the National Patient Safety Agency, 11 deaths and one case of serious harm occurred due to misplaced nasogastric feeding tubes over a two-year period. It is therefore vital for staff inserting these tubes to know both the correct insertion methods and the procedure for verifying their correct intragastric positioning.

  12. A nurse led peripherally inserted central catheter line insertion service is effective with radiological support

    International Nuclear Information System (INIS)

    Barber, Jonathan M.; Booth, Doris M.; King, Julia A.; Chakraverty, Sam

    2002-01-01

    AIM: Peripherally inserted central catheters (PICC) are increasingly used as a route of chemotherapy administration. Our aims were to assess a collaborative approach to PICC placement, with radiological support for a nurse led line insertion service in a minority of cases, and to determine whether PICC provided a safe and reliable method of chemotherapy administration. MATERIALS AND METHODS: Prospective data on 100 consecutive patients undergoing PICC placement for chemotherapy were collected. Lines were inserted by ward based nurses or under ultrasound guidance by radiologists. End points were successful completion of treatment or patient death. RESULTS: One hundred and forty-four lines were placed for 118 courses of chemotherapy. 107 (74%) were placed by nurses and 37 (26%) by radiologists. Ninety-five percent of patients completed therapy with either one or two lines. Seventy percent of lines were removed on achieving the primary end points. In two additional patients PICC could not be placed radiologically. Twelve patients were unable to complete treatment with PICC alone, nine of these required an alternative administration route. The catheter related sepsis rate was 4.9%. CONCLUSION: The majority of PICC can be successfully placed by trained nurses, reserving image guidance only for more difficult cases. PICC have an acceptable complication profile, and decrease the need for tunnelled central lines. Barber, J.M. et al. (2002)

  13. Insertion torque versus mechanical resistance of mini-implants inserted in different cortical thickness.

    Science.gov (United States)

    Santos, Renata Faria; Ruellas, Antonio Carlos de Oliveira; Fernandes, Daniel Jogaib; Elias, Carlos Nelson

    2014-01-01

    This study aimed to measure insertion torque, tip mechanical resistance to fracture and transmucosal neck of mini-implants (MI) (Conexão Sistemas de PróteseT), as well as to analyze surface morphology. Mechanical tests were carried out to measure the insertion torque of MIs in different cortical thicknesses, and tip mechanical resistance to fracture as well as transmucosal neck of MIs. Surface morphology was assessed by scanning electron microscopy (SEM) before and after the mechanical tests. Values of mechanical resistance to fracture (22.14 N.cm and 54.95 N.cm) were higher and statistically different (P 0.05) to torsional fracture in the tip of MI (22.14 N.cm) when 3 mm cortical thickness (16.11 N.cm) and dense bone (23.95 N.cm) were used. Torsional fracture of the transmucosal neck (54.95 N.cm) was higher and statistically different (P mini-implants tested presented adequate surface morphology. The resistance of mini-implants to fracture safely allows placement in 1 and 2-mm cortical thickness. However, in 3-mm cortical thickness and dense bones, pre-drilling with a bur is recommended before insertion.

  14. Insertion torque versus mechanical resistance of mini-implants inserted in different cortical thickness

    Science.gov (United States)

    Santos, Renata de Faria; Ruellas, Antonio Carlos de Oliveira; Fernandes, Daniel Jogaib; Elias, Carlos Nelson

    2014-01-01

    Objective This study aimed to measure insertion torque, tip mechanical resistance to fracture and transmucosal neck of mini-implants (MI) (Conexão Sistemas de PróteseT), as well as to analyze surface morphology. Methods Mechanical tests were carried out to measure the insertion torque of MIs in different cortical thicknesses, and tip mechanical resistance to fracture as well as transmucosal neck of MIs. Surface morphology was assessed by scanning electron microscopy (SEM) before and after the mechanical tests. Results Values of mechanical resistance to fracture (22.14 N.cm and 54.95 N.cm) were higher and statistically different (P 0.05) to torsional fracture in the tip of MI (22.14 N.cm) when 3 mm cortical thickness (16.11 N.cm) and dense bone (23.95 N.cm) were used. Torsional fracture of the transmucosal neck (54.95 N.cm) was higher and statistically different (P mini-implants tested presented adequate surface morphology. The resistance of mini-implants to fracture safely allows placement in 1 and 2-mm cortical thickness. However, in 3-mm cortical thickness and dense bones, pre-drilling with a bur is recommended before insertion. PMID:25162571

  15. A nurse led peripherally inserted central catheter line insertion service is effective with radiological support

    Energy Technology Data Exchange (ETDEWEB)

    Barber, Jonathan M.; Booth, Doris M.; King, Julia A.; Chakraverty, Sam

    2002-05-01

    AIM: Peripherally inserted central catheters (PICC) are increasingly used as a route of chemotherapy administration. Our aims were to assess a collaborative approach to PICC placement, with radiological support for a nurse led line insertion service in a minority of cases, and to determine whether PICC provided a safe and reliable method of chemotherapy administration. MATERIALS AND METHODS: Prospective data on 100 consecutive patients undergoing PICC placement for chemotherapy were collected. Lines were inserted by ward based nurses or under ultrasound guidance by radiologists. End points were successful completion of treatment or patient death. RESULTS: One hundred and forty-four lines were placed for 118 courses of chemotherapy. 107 (74%) were placed by nurses and 37 (26%) by radiologists. Ninety-five percent of patients completed therapy with either one or two lines. Seventy percent of lines were removed on achieving the primary end points. In two additional patients PICC could not be placed radiologically. Twelve patients were unable to complete treatment with PICC alone, nine of these required an alternative administration route. The catheter related sepsis rate was 4.9%. CONCLUSION: The majority of PICC can be successfully placed by trained nurses, reserving image guidance only for more difficult cases. PICC have an acceptable complication profile, and decrease the need for tunnelled central lines. Barber, J.M. et al. (2002)

  16. Insertion mechanics of bioinspired needles into soft tissues.

    Science.gov (United States)

    Sahlabadi, Mohammad; Khodaei, Seyedvahid; Jezler, Kyle; Hutapea, Parsaoran

    2017-12-22

    Most studies to date confirm that any increase in the needle insertion force increases the damage to the tissue. When it comes to brain tissue, even minor damage can cause a long-lasting traumatic brain injury. Thus there is a great demand for innovative minimally invasive needles among the medical community. In our previous studies a novel bioinspired needle design with specially designed barbs was used to perform insertion tests into Polyvinyl chloride (PVC) tissue-mimicking gels, in which it decreased the insertion force by as much as 25%. In this work, bioinspired needles were designed using a CAD software, and were then manufactured using a 3 D printer. The insertion tests into bovine brain and liver were then performed to further investigate the performance of our bioinspired needles in real tissues. Our results show that there was a 10-25% decrease in the insertion force for insertions into bovine brain, and a 35-45% reduction in the insertion force for insertions into bovine liver using the proposed bioinspired needles. The reduction in the insertion force is due to the decrease in the friction force of the bioinspired needle with the bovine tissues, and its results are consistent with our previous results.

  17. Effect of vibration frequency on biopsy needle insertion force.

    Science.gov (United States)

    Tan, Lei; Qin, Xuemei; Zhang, Qinhe; Zhang, Hongcai; Dong, Hongjian; Guo, Tuodang; Liu, Guowei

    2017-05-01

    Needle insertion is critical in many clinical medicine procedures, such as biopsy, brachytherapy, and injection therapy. A platform with two degrees of freedom was set up to study the effect of vibration frequency on needle insertion force. The gel phantom deformation at the needle cutting edge and the Voigt model are utilized to develop a dynamic model to explain the relationship between the insertion force and needle-tip velocity. The accuracy of this model was verified by performing needle insertions into phantom gel. The effect of vibration on insertion force can be explained as the vibration increasing the needle-tip velocity and subsequently increasing the insertion force. In a series of needle insertion experiments with different vibration frequencies, the peak forces were selected for comparison to explore the effect of vibration frequency on needle insertion force. The experimental results indicate that the insertion force at 500Hz increases up to 17.9% compared with the force at 50Hz. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  18. Development of collimator insert for linac based stereotactic irradiation

    International Nuclear Information System (INIS)

    Singh, I.R.R.; Brindha, S.; Ravindran, B.P.; Rajshekhar, V.

    1999-01-01

    The aim of this study is to develop collimator inserts of various sizes which are either not commercially available or are expensive to import. The dosimetry parameters such as tissue maximum ratio (TMR), off-axis ratio (OAR) and output factor of the developed collimator insert are compared with that of the commercial collimator insert (Radionics). In order to check the suitability of the collimator insert developed locally for clinical use and to standardize the method of development, a collimator insert of 15 mm identical to the one supplied by Radionics is developed with low-melting alloy (Cerrobend). Moreover for the clinical use of the developed collimator insert, certain acceptance tests are performed which include a collimator concentricity test, beam size check and radiation leakage test. The dose verification is carried out with a thermoluminescent dosimeter ( 7 LiF rods) and an FBX chemical dosimeter in a human-head-shaped Perspex phantom filled with water. The variation between the calculated and measured dose is found to be within +2.4% for 7 LiF rods and -2.0% for the FBX chemical dosimeter thus ensuring the suitability of the developed collimator insert for clinical use. This has encouraged us to standardize the method adapted to develop the collimator insert and to develop collimator inserts of different field sizes. (author)

  19. Intrauterine device insertion in the postpartum period: a systematic review.

    Science.gov (United States)

    Sonalkar, Sarita; Kapp, Nathalie

    2015-02-01

    Given new research on postpartum placement of levonorgestrel and copper intrauterine devices (IUDs), our objective was to update a prior systematic review of the safety and expulsion rates of postpartum IUDs. We searched MEDLINE, CENTRAL, LILACS, POPLINE, Web of Science, and ClinicalTrials.gov databases for articles between the database inception until July 2013. We included studies that compared IUD insertion time intervals and routes during the postpartum period. We used standard abstract forms and the United States Preventive Services Task Force grading system to summarise and assess the quality of the evidence. We included 18 articles. New evidence suggests that a levonorgestrel releasing-intrauterine system (LNG-IUS) insertion within 48 hours of delivery is safe. Postplacental insertion and insertion between 10 minutes and 48 hours after delivery result in higher expulsion rates than insertion 4 to 6 weeks postpartum, or non-postpartum insertion. Insertion at the time of caesarean section is associated with lower expulsion rates than postplacental insertion at the time of vaginal delivery. This review supports the evidence that insertion of an intrauterine contraceptive within the first 48 hours of vaginal or caesarean delivery is safe. Expulsion rates should be further studied in larger randomised controlled trials.

  20. Insertional footprint anatomy of the pectoralis major tendon.

    Science.gov (United States)

    Carey, Paul; Owens, Brett D

    2010-01-01

    Correct anatomical repair of pectoralis major tendon injuries requires accurate identification of the humeral insertion site. In the absence of residual fibers at the insertion, proper placement requires knowledge of the anatomic relationships in the proximal humerus. This anatomic study attempts to measure these relationships and the dimensions of the insertional footprint to assist in surgical repair and reconstruction. Six matched pairs of cadaver proximal humeri were examined. All specimens were found to be in good condition and none were excluded. The proximal to distal length and maximum width of the pectoralis major tendon were measured at the humeral insertion with a digital caliper. The distance from the superomedial corner of the greater tuberosity to the superior aspect of the tendon insertion was also measured. The mean proximal to distal dimension of the pectoralis major insertion was 72.3+/-12.3 mm. The mean maximal thickness at the humeral insertion was 1.4+/-.2 mm. The distance from the superomedial corner of the greater tuberosity to the bony tendon insertion was 42.2+/-8.5 mm. The anatomic location of the humeral insertion of the pectoralis major tendon can be located in repair of pectoralis tendon injuries by referencing the superomedial corner of the greater tuberosity and the lateral lip of the bicipital groove. Findings in the present study will improve knowledge of the surgical anatomy relevant to repair and reconstruction of the pectoralis major tendon. Copyright 2010, SLACK Incorporated.

  1. The ATLAS Insertable B-Layer Project

    CERN Document Server

    Miucci, A; The ATLAS collaboration

    2014-01-01

    The ATLAS experiment will upgrade its Pixel Detector with the installation of a new pixel layer in 2013-14. The new sub-detector, named Insertable B-layer (IBL), will be installed between the existing Pixel Detector and a new smaller radius beam-pipe at a radius of 3.3 cm. To cope with the high radiation and pixel occupancy due to the proximity to the interaction point, a new read-out chip and two different silicon sensor technologies (planar and 3D) have been de- veloped. Furthermore, the physics performance should be improved through the reduction of pixel size while a low material budget should be imposed. A new mechanical support using lightweight staves and a CO2 based cooling system is used. An overview of the IBL project and the status of the production of staves and the qualification of the assembly procedure, the loaded module electrical integrity and the read-out chain will be presented.

  2. The ATLAS Insertable B-Layer

    CERN Document Server

    Alkire, S P; The ATLAS collaboration

    2014-01-01

    During the first shutdown of LHC, the ATLAS detector is undergoing an upgrade of the Pixel Detector in preparation for high luminosity LHC. This upgrade consists of a new pixel layer, called the Insertable B-Layer (IBL), which is positioned between the former inner layer of the Pixel Detector (B-Layer) and a new, smaller, beam pipe, at a radial distance of 3.3 cm from the beam axis. The realization of the IBL required the development of several new technologies and solutions in order to overcome the challenges introduced by the extreme environment and working conditions, such as the high radiation levels, the high pixel occupancy and the need of an exceptionally low material budget. Two silicon sensor technologies have been adopted for the IBL modules: planar n-in-n and 3D. Both of these are connected via bump bonding to the new generation 130 nm IBM CMOS FE-I4 front-end read-out chip. An overview of the IBL project, module design, the qualification tests, data acquisition, results and performance is presente...

  3. ABO blood group related venous thrombosis risk in patients with peripherally inserted central catheters.

    Science.gov (United States)

    Koo, Chung Mo; Vissapragada, Ravi; Sharp, Rebecca; Nguyen, Phi; Ung, Thomas; Solanki, Chrismin; Esterman, Adrian

    2018-02-01

    To investigate the association between ABO blood group and upper limb venous thrombosis (VT) risk in patients with peripherally inserted central catheters (PICC). Single centre retrospective cohort study. A cohort of patients who underwent PICC insertion from September 2010 to August 2014 were followed up for symptomatic VT presentations diagnosed by ultrasound. Blood group status was identified from hospital information systems. 2270 participants had 3020 PICCs inserted. There were 124 cases of symptomatic VT, an incident rate of 4% [95% confidence interval, CI (3-5%)]. Univariate analysis adjusting for the clustered sample showed that having chemotherapy, two or more previous PICCs, a larger catheter size, a diagnosis of cancer and having a blood group B were all associated with an increased risk of a VT. In the multivariate analysis, PICC diameter, cancer diagnosis and blood group B were all independently associated with increased risk of VT. Patients undergoing PICC insertion with a blood group B appear to have a higher risk of VT, independent of risks attached to the PICC procedure and cancer diagnosis. Without any existing guidelines for PICC-related VT, this investigation creates a platform for further research to be conducted in order to establish guidelines. Advances in knowledge: Previous studies investigating VT risk associated with blood group status related to large heterogeneous populations. In this article, we look at patients specifically with PICC, which reduces the heterogeneity in the cohort. In addition, due to the substantial number of patients enrolled, we had a chance to perform multivariate analyses with statistical significance.

  4. Structural basis of Sec-independent membrane protein insertion by YidC.

    Science.gov (United States)

    Kumazaki, Kaoru; Chiba, Shinobu; Takemoto, Mizuki; Furukawa, Arata; Nishiyama, Ken-ichi; Sugano, Yasunori; Mori, Takaharu; Dohmae, Naoshi; Hirata, Kunio; Nakada-Nakura, Yoshiko; Maturana, Andrés D; Tanaka, Yoshiki; Mori, Hiroyuki; Sugita, Yuji; Arisaka, Fumio; Ito, Koreaki; Ishitani, Ryuichiro; Tsukazaki, Tomoya; Nureki, Osamu

    2014-05-22

    Newly synthesized membrane proteins must be accurately inserted into the membrane, folded and assembled for proper functioning. The protein YidC inserts its substrates into the membrane, thereby facilitating membrane protein assembly in bacteria; the homologous proteins Oxa1 and Alb3 have the same function in mitochondria and chloroplasts, respectively. In the bacterial cytoplasmic membrane, YidC functions as an independent insertase and a membrane chaperone in cooperation with the translocon SecYEG. Here we present the crystal structure of YidC from Bacillus halodurans, at 2.4 Å resolution. The structure reveals a novel fold, in which five conserved transmembrane helices form a positively charged hydrophilic groove that is open towards both the lipid bilayer and the cytoplasm but closed on the extracellular side. Structure-based in vivo analyses reveal that a conserved arginine residue in the groove is important for the insertion of membrane proteins by YidC. We propose an insertion mechanism for single-spanning membrane proteins, in which the hydrophilic environment generated by the groove recruits the extracellular regions of substrates into the low-dielectric environment of the membrane.

  5. The development of a risk score for unplanned removal of peripherally inserted central catheter in newborns

    Directory of Open Access Journals (Sweden)

    Priscila Costa

    2015-06-01

    Full Text Available OBJECTIVE: to develop a risk score for unplanned removal of peripherally inserted central catheter in newborns.METHOD: prospective cohort study conducted in a neonatal intensive care unit with newborn babies who underwent 524 catheter insertions. The clinical characteristics of the newborn, catheter insertion and intravenous therapy were tested as risk factors for the unplanned removal of catheters using bivariate analysis. The risk score was developed using logistic regression. Accuracy was internally validated based on the area under the Receiver Operating Characteristic curve.RESULTS: the risk score was made up of the following risk factors: transient metabolic disorders; previous insertion of catheter; use of a polyurethane double-lumen catheter; infusion of multiple intravenous solutions through a single-lumen catheter; and tip in a noncentral position. Newborns were classified into three categories of risk of unplanned removal: low (0 to 3 points, moderate (4 to 8 points, and high (≥ 9 points. Accuracy was 0.76.CONCLUSION: the adoption of evidence-based preventative strategies based on the classification and risk factors faced by the newborn is recommended to minimize the occurrence of unplanned removals.

  6. The timing of norplant insertion and postpartum depression in teenagers.

    Science.gov (United States)

    Stevens-Simon, C; Kelly, L; Wallis, J

    2000-06-01

    This study tested the hypothesis that teenagers who have Norplant inserted during the puerperium report more depressive symptoms during the first postpartum year than their peers who do not receive Norplant. We studied the prevalence of depressive symptoms in a group of 212 mothers aged 19 years less, in relation to the timing of Norplant insertion. The participants were divided into 3 groups: 100 (47%) had Norplant inserted during the puerperium (early Norplant users); 72 (34%) had Norplant inserted during the next 10 months (late Norplant users); and 40 (19%) used other contraceptives (40% oral contraceptives; 17% condoms; 43% nothing). Depressive symptoms were measured with the Center for Epidemiologic Studies - Depression Scale. Postpartum depression was defined as a scale score >/=16, 6-12 months after Norplant insertion or delivery. Variables examined as potential confounders were identified a priori from a review of the literature and controlled for in analysis of variance. At delivery, members of the 3 contraceptive groups did not differ significantly with regard to age, race, parity, educational, marital, or socioeconomic status. Late Norplant users were, however, more apt to have new boyfriends (p =. 03), to rate the support they received from the baby's father as poor (p =.004), and experience depression prior to Norplant insertion (p =.02). Contrary to the study hypothesis, late rather than early Norplant insertion was associated with postpartum depression. Multivariate analyses identified 3 independent predictors of the severity of depressive symptoms at follow-up (depression prior to Norplant insertion, a new boyfriend at delivery, and late Norplant insertion); R(2) = 41.3%. Contrary to the study hypothesis, puerperal Norplant insertion did not exacerbate postpartum depression. Delaying Norplant insertion may increase the risk of depression during the first postpartum year, particularly in teenagers with other psychosocial risk factors.

  7. Clinical information in drug package inserts in India

    Directory of Open Access Journals (Sweden)

    Shivkar Y

    2009-01-01

    Full Text Available Background: It is widely recognized that accurate and reliable product information is essential for the safe and effective use of medications. Pharmaceutical companies are the primary source of most drug information, including package inserts. Package inserts are printed leaflets accompanying marketed drug products and contain information approved by the regulatory agencies. Studies on package inserts in India, in 1996, had shown that crucial information was often missing and they lacked uniformity. Aim: To assess the presentation and completeness of clinically important information provided in the currently available package inserts in India. Materials and Methods: Package inserts accompanying allopathic drug products marketed by pharmaceutical companies in India were collected. These package inserts were analyzed for the content of clinically important information in various sections. Statistical Analysis: The results were expressed as absolute numbers and percentages. Results: Preliminary analyses revealed that most package inserts did contain information under headings, such as, therapeutic indications, contraindications, undesirable effects, etc., listed in the Drugs and Cosmetics Rules 1945. The findings indicated considerable improvement in package inserts since 1996. However, on critical evaluation it was revealed that clinically important information was not well presented and was often incomplete. Information with regard to pediatric and geriatric use was present in only 44% and 13% of the package inserts, respectively. Only five of the inserts had information on the most frequent adverse drug reactions associated with the drug. Also, information on interactions and overdosage was often missing. Conclusion: Although the package inserts appear to have improved over the past decade there is still a definite need to further refine the clinical information contained, to minimize the risks to patients. This could be brought about by self

  8. Test Results for LHC Insertion Region Dipole Magnets

    CERN Document Server

    Muratore, Joseph F; Cozzolino, John P; Ganetis, George; Ghosh, Arup; Gupta, Ramesh C; Harrison, Michael; Kumar-Jain, Animesh; Marone, Andrew; Richard-Plate, Stephen; Schmalzle, Jesse D; Thomas, Richard A; Wanderer, Peter; Willen, Erich; Wu, Kuo-Chen

    2005-01-01

    The Superconducting Magnet Division at Brookhaven National Laboratory (BNL) has made 20 insertion region dipoles for the Large Hadron Collider (LHC) at CERN. These 9.45 m-long, 8 cm aperture magnets have the same coil design as the arc dipoles now operating in the Relativistic Heavy Ion Collider (RHIC) at BNL and are of single aperture, twin aperture, and double cold mass configurations. They produce fields up to 3.8 T for operation at 7.56 TeV. Eighteen of these magnets have been tested at 4.5 K using either forced flow supercritical helium or liquid helium. The testing was especially important for the twin aperture models, which have the most challenging design. In these, the dipole fields in both apertures point in the same direction, unlike LHC arc dipoles. This paper reports on the results of these tests, including spontaneous quench performance, verification of quench protection heater operation, and magnetic field quality. Magnetic field measurements were done at 4.5K and at room temperature, and warm-...

  9. Manufacture of the poloidal field conductor insert coil (PFCI)

    Energy Technology Data Exchange (ETDEWEB)

    Baker, W. [EFDA CSU Garching, Boltzmannstrasse 2, 85748 Garching bei Muenchen (Germany); Keefe, C. [Tesla Engineering, Storrington, Sussex (United Kingdom); Rajainmaeki, H. [EFDA CSU Garching, Boltzmannstrasse 2, 85748 Garching bei Muenchen (Germany)], E-mail: hannu.rajainmaki@tech.efda.org; Salpietro, E. [EFDA CSU Garching, Boltzmannstrasse 2, 85748 Garching bei Muenchen (Germany)

    2007-10-15

    Within the framework of the R and D programme for international thermonuclear experimental reactor (ITER) the European team European Fusion Development Agreement (EFDA) has been charged with the design and manufacture of the poloidal field conductor insert coil (PFCI). The purpose of the PFCI is to test and demonstrate the performance of long-length full-scale NbTi conductors in ITER-relevant conditions. The PFCI will be tested in the central solenoid model coil test facility at the JAEA, Naka, Japan. This paper details the complete manufacturing of the PFCI including development, forming machining, pre-assembly, impregnation, final assembly and testing. The PFCI is a single-layered wound solenoid of nine turns with a transition joggle in the centre section of the winding and an intermediate joint connection between the upper termination and the main coil winding. To give the required overall dimensions to fit in the testing facility, preformed and machined glass resin composite filler pieces are assembled with the winding and is finally vacuum pressure impregnated (VPI) to create a single assembly unit. The PFCI is enclosed for assembly in a support structure, which consists of an upper and lower flange, each made up of four electrically insulated machined stainless steel castings, and 12 tie rods preloading the complete assembly in the vertical direction. The upper flange is equipped with four radial restraining jacks and the lower flange is equipped with four sets of studs and shear keys to withstand the net vertical and lateral electromagnetic forces. The PFCI is equipped with inductive heaters, voltage taps, temperature transducers, strain gauges and other instrumentation as diagnostics to monitor the performance. The current status of the manufacture is that the coil has passed the final acceptance tests and it is in the support structure assembly stage.

  10. Polymorphism of angiotensin converting enzyme (insertion/deletion ...

    Indian Academy of Sciences (India)

    and electrolyte balance, and blood pressure (Malik et al. 1997) contains a ... of diverse population groups with a variable prevalence of hypertension .... group were in HWE. The 287-bp insertion/deletion polymorphism located in intron 16 of ACE gene was detected by PCR analysis in the three ethnic groups. The insertion ...

  11. Load beam unit replaceable inserts for dry coal extrusion pumps

    Science.gov (United States)

    Saunders, Timothy; Brady, John D.

    2012-11-13

    A track assembly for a particulate material extrusion pump according to an exemplary aspect of the present disclosure includes a link assembly with a roller bearing. An insert mounted to a load beam located such that the roller bearing contacts the insert.

  12. Lack of association of insertion/deletion polymorphism in ...

    African Journals Online (AJOL)

    In the present preliminary study the insertion/deletion polymorphism within angiotensin converting enzyme gene is not likely to be associated with nephropathy in type 2 diabetic patients of Punjabi population of Pakistan. Key words: Angiotensin converting enzymes, insertion/deletion polymorphism, albuminuria and type 2 ...

  13. Inactivation of a transgene due to transposition of insertion ...

    Indian Academy of Sciences (India)

    Agrobacterium strains harbour insertion sequences, which are known to transpose into genomes as well as into Ti plasmids. In this study we report the inactivation of a transgene due to transposition of the A. tumefaciens insertion sequence IS136. The transposition was discovered following transformation of plant tissues, ...

  14. Forward and reverse genetics: The LORE1 retrotransposon insertion mutants

    DEFF Research Database (Denmark)

    Fukai, Eigo; Malolepszy, Anna; Sandal, Niels Nørgaard

    2014-01-01

    The endogenous Lotus retrotransposon 1 (LORE1) transposes in the germ line of Lotus japonicus plants that carry an active element. This feature of LORE1 has been exploited for generation of a large non-transgenic insertion mutant population, where insertions have been annotated using next-generat...

  15. Enhanced citrate production through gene insertion in Aspergillus niger

    DEFF Research Database (Denmark)

    Jongh, Wian de; Nielsen, Jens

    2007-01-01

    The effect of inserting genes involved in the reductive branch of the tricarboxylic acid (TCA) cycle on citrate production by Aspergillus niger was evaluated. Several different genes were inserted individually and in combination, i.e. malate dehydrogenase (mdh2) from Saccharomyces cerevisiae, two...

  16. Ultrasonic Guided Insertion of Central Venous Catheter in Infants ...

    African Journals Online (AJOL)

    Background/Purpose: ultrasound is licensed for application of regional blocks and insertion of vascular access. We aimed to compare ultrasonic guided (USG) and anatomical landmark technique (ALT) for insertion of central venous catheter (CVC) as regard success rate and rate of complications in infants and children.

  17. Nurse-led PICC insertion: is it cost effective?

    Science.gov (United States)

    Walker, Graham; Todd, Alistair

    Repeated attempts to cannulate small veins can cause considerable distress for patients and expend substantial staff time.For longer term venous access, a peripherally inserted central catheter(PICC) may be used instead of a peripheral cannula. Previous studies indicate that insertion of a PICC costs three times more than a cannula but the lifespan is substantially longer. This study aimed to compare insertion cost, patient satisfaction, and infection rates of PICCs for the two main staff groups (trained nurses and radiologists) inserting these devices in a district general hospital. The study took place over 4 months in 2012-13.A questionnaire was attached to all identified PICCs in stock at Raigmore Hospital to collect details of the date of insertion, patient involved, time taken, attendant staff grade and experience level,consumables used and insertion success. The lead author's personal observation of PICC insertion by different staff groups allowed estimation of staff time, costs and success rates. Patient experience and satisfaction was assessed before and after insertion using a patient questionnaire. PICC longevity, infection rates and failures were assessed by review of patient notes. The radiologist group had a statistically significant (pPICCs can be safely performed without x-ray screening in a ward-based environment. This is likely to be the most cost-effective solution for large volume services.

  18. Nurse-led PICC insertion: is it cost effective?

    Science.gov (United States)

    Walker, Graham; Todd, Alistair

    2013-10-24

    Repeated attempts to cannulate small veins can cause considerable distress for patients and expend substantial staff time. For longer term venous access, a peripherally inserted central catheter (PICC) may be used instead of a peripheral cannula. Previous studies indicate that insertion of a PICC costs three times more than a cannula but the lifespan is substantially longer. This study aimed to compare insertion cost, patient satisfaction, and infection rates of PICCs for the two main staff groups (trained nurses and radiologists) inserting these devices in a district general hospital. The study took place over 4 months in 2012-13. A questionnaire was attached to all identified PICCs in stock at Raigmore Hospital to collect details of the date of insertion, patient involved, time taken, attendant staff grade and experience level, consumables used and insertion success. The lead author's personal observation of PICC insertion by different staff groups allowed estimation of staff time, costs and success rates. Patient experience and satisfaction was assessed before and after insertion using a patient questionnaire. PICC longevity, infection rates and failures were assessed by review of patient notes. The radiologist group had a statistically significant (pPICCs can be safely performed without x-ray screening in a ward-based environment. This is likely to be the most cost-effective solution for large volume services.

  19. Anterior transarticular C1-C2 fixation with contralateral screw insertion: a report of two cases and technical note.

    Science.gov (United States)

    Lvov, Ivan; Grin, Andrey; Kaykov, Aleksandr; Smirnov, Vladimir; Krylov, Vladimir

    2017-08-08

    Anterior transarticular fixation of the C1-C2 vertebrae is a well-known technique that involves screw insertion through the body of the C2 vertebra into the lateral masses of the atlas through an anterior transcervical approach. Meanwhile, contralateral screw insertion has been previously described only in anatomical studies. We describe two case reports of the clinical application of this new technique. In Case 1, the patient was diagnosed with an unstable C1 fracture. The clinical features of the case did not allow for any type of posterior atlantoaxial fusion, Halo immobilization, or routine anterior fixation using the Reindl and Koller techniques. The possible manner of screw insertion into the anterior third of the right lateral mass was via a contralateral trajectory, which was performed in this case. Case 2 involved a patient with neglected posteriorly dislocated dens fracture who could not lie in the prone position due to concomitant cardiac pathology. Reduction of atlantoaxial dislocation was insufficient, even after scar tissue resection at the fracture, while transdental fusion was not possible. Considering the success of the previous case, atlantoaxial fixation was performed through the small approach, using the Reindl technique and contralateral screw insertion. These two cases demonstrate the potential of anterior transarticular fixation of C1-C2 vertebrae in cases where posterior atlantoaxial fusion is not achievable. This type of fixation can be performed through a single approach if one screw is inserted using the Reindl technique and another is inserted via a contralateral trajectory.

  20. Measurement of Vein Diameter for Peripherally Inserted Central Catheter (PICC) Insertion: An Observational Study.

    Science.gov (United States)

    Sharp, Rebecca; Cummings, Melita; Childs, Jessie; Fielder, Andrea; Mikocka-Walus, Antonina; Grech, Carol; Esterman, Adrian

    2015-01-01

    Choosing an appropriately sized vein reduces the risk of venous thromboembolism associated with peripherally inserted central catheters. This observational study described the diameters of the brachial, basilic, and cephalic veins and determined the effect of patient factors on vein size. Ultrasound was used to measure the veins of 176 participants. Vein diameter was similar in both arms regardless of hand dominance and side. Patient factors-including greater age, height, and weight, as well as male gender-were associated with increased vein diameter. The basilic vein tended to have the largest diameter statistically. However, this was the case in only 55% of patients.

  1. Turbine airfoil having near-wall cooling insert

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Jr., Nicholas F.; Wiebe, David J.

    2017-09-12

    A turbine airfoil is provided with at least one insert positioned in a cavity in an airfoil interior. The insert extends along a span-wise extent of the turbine airfoil and includes first and second opposite faces. A first near-wall cooling channel is defined between the first face and a pressure sidewall of an airfoil outer wall. A second near-wall cooling channel is defined between the second face and a suction sidewall of the airfoil outer wall. The insert is configured to occupy an inactive volume in the airfoil interior so as to displace a coolant flow in the cavity toward the first and second near-wall cooling channels. A locating feature engages the insert with the outer wall for supporting the insert in position. The locating feature is configured to control flow of the coolant through the first or second near-wall cooling channel.

  2. Combining M-FISH and Quantum Dot technology for fast chromosomal assignment of transgenic insertions

    Directory of Open Access Journals (Sweden)

    Yusuf Mohammed

    2011-12-01

    Full Text Available Abstract Background Physical mapping of transgenic insertions by Fluorescence in situ Hybridization (FISH is a reliable and cost-effective technique. Chromosomal assignment is commonly achieved either by concurrent G-banding or by a multi-color FISH approach consisting of iteratively co-hybridizing the transgenic sequence of interest with one or more chromosome-specific probes at a time, until the location of the transgenic insertion is identified. Results Here we report a technical development for fast chromosomal assignment of transgenic insertions at the single cell level in mouse and rat models. This comprises a simplified 'single denaturation mixed hybridization' procedure that combines multi-color karyotyping by Multiplex FISH (M-FISH, for simultaneous and unambiguous identification of all chromosomes at once, and the use of a Quantum Dot (QD conjugate for the transgene detection. Conclusions Although the exploitation of the unique optical properties of QD nanocrystals, such as photo-stability and brightness, to improve FISH performance generally has been previously investigated, to our knowledge this is the first report of a purpose-designed molecular cytogenetic protocol in which the combined use of QDs and standard organic fluorophores is specifically tailored to assist gene transfer technology.

  3. Synthesis and insertion chemistry of mixed tether uranium metallocene complexes

    Energy Technology Data Exchange (ETDEWEB)

    Siladke, Nathan A.; LeDuc, Jennifer; Ziller, Joseph W.; Evans, William J. [Department of Chemistry, University of California, Irvine, CA (United States)

    2012-11-12

    The synthesis of mixed tethered alkyl uranium metallocenes has been investigated by examining the reactivity of the bis(tethered alkyl) metallocene [(η{sup 5}-C{sub 5}Me{sub 4}SiMe{sub 2}CH{sub 2}-κC){sub 2}U] (1) with substrates that react with only one of the U-C linkages. The effect of these mixed tether coordination environments on the reactivity of the remaining U-C bond has been studied by using CO insertion chemistry. One equivalent of azidoadamantane (AdN{sub 3}) reacts with 1 to yield the mixed tethered alkyl triazenido complex [(η{sup 5}-C{sub 5}Me{sub 4}SiMe{sub 2}CH{sub 2}-κC)U(η{sup 5}-C{sub 5}Me{sub 4}SiMe{sub 2}-CH{sub 2}NNN-Ad-κ{sup 2}N{sup 1,3})]. Similarly, a single equivalent of CS{sub 2} reacts with 1 to form the mixed tethered alkyl dithiocarboxylate complex [(η{sup 5}-C{sub 5}Me{sub 4}SiMe{sub 2}CH{sub 2}-κC)U(η{sup 5}-C{sub 5}Me{sub 4}SiMe{sub 2}- CH{sub 2}C(S){sub 2}-κ{sup 2}S,S{sup '})], a reaction that constitutes the first example of CS{sub 2} insertion into a U{sup 4+}-C bond. Complex 1 reacts with one equivalent of pyridine N-oxide by C-H bond activation of the pyridine ring to form a mixed tethered alkyl cyclometalated pyridine N-oxide complex [(η{sup 5}-C{sub 5}Me{sub 4}SiMe{sub 2}CH{sub 2}-κC)(η{sup 5}-C{sub 5}Me{sub 4}SiMe{sub 3})U(C{sub 6}H{sub 4}NO-κ{sup 2} C,O)]. The remaining (η{sup 5}-C{sub 5}Me{sub 4}SiMe{sub 2}CH{sub 2}-κC){sup 2-} ligand in each of these mixed tethered species show reactivity towards CO and tethered enolate ligands form by insertion. Subsequent rearrangement have been identified in [(η{sup 5}-C{sub 5}Me{sub 4}SiMe{sub 3})U(C{sub 5}H{sub 4}NO-κ{sup 2}C,O)(η{sup 5}-C{sub 5}Me{sub 4}SiMe{sub 2}C(=CH{sub 2})O- κO)] and [(η{sup 5}-C{sub 5}Me{sub 4}SiMe{sub 2}CH{sub 2}NNN-Ad-κ{sup 2}N{sup 1,3})U(η{sup 5}-C{sub 5}Me{sub 4}SiMe{sub 2}C(=CH{sub 2})O-κO)]. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  4. Peripherally-inserted Central Catheter (PICC Insertion in Neonates: Apnea and Radiocontrasts Complications

    Directory of Open Access Journals (Sweden)

    Eissa Bilehjani

    2015-01-01

    Full Text Available The importance of pain management throughout minimally-invasive procedures such as peripherally-inserted central catheter (PICC insertion is an inevitable fact. However, administration of varied analgesics, especially opioids, in specific age ranges such as neonate could be of immense concern. Most of these patients are on different medications, especially those hospitalized in the ICUs or with critical conditions. Neonates receiving continuous opioid infusions might also require an additional opioid bolus to control the associated pain (1. Importantly, it should be taken into consideration that administration of opioids or even a light sedation would increase the risk of delayed apnea in this group of patients (2. Factors contributing to this complication include ex-premature infants (gestational age<37 weeks, premature infants younger than 46 weeks’ postconceptual age and anemia (hematocrit< 30% (3, 4. Hence, it is recommended to use other supplementary analgesic techniques including local or topical anesthesia, especially in neonates having previously received continuous or bolus opioids. Furthermore, supplementary techniques assisting the confirmation of proper placement such as overpenetrating the radiograph, lateral X-rays and positioning the infant for a lateral oblique radiograph (right side elevated at a 10°–15° angle are frequently used by clinicians to avoid administration of radiocontrasts and their associated complications. In the latter technique, catheter visualization could be enhanced as the PICC will not be superimposed over the mediastinal structures (5, 6.

  5. In vitro tests for aerosol deposition. III: effect of inhaler insertion angle on aerosol deposition.

    Science.gov (United States)

    Delvadia, Renish R; Longest, P Worth; Hindle, Michael; Byron, Peter R

    2013-06-01

    Inhaler orientation with respect to a patient's mouth may be an important variable determining the efficiency of aerosol lung delivery. The effect of insertion angle on regional deposition was evaluated for a series of inhalers using concurrent in vitro and computational fluid dynamics (CFD) analysis. Geometrically realistic physical mouth-throat (MT) and upper tracheobronchial (TB) models were constructed to connect different inhalers at a series of insertion angles relative to the horizontal plane of the model. These models were used to assess albuterol sulfate deposition from the Novolizer(®) dry powder inhaler (DPI), Proventil(®) HFA pressurized metered dose inhaler (MDI), and Respimat(®) Soft Mist™ Inhaler (SMI) following the actuation of a single dose. Drug deposition from Novolizer DPI was studied for Salbulin(®) and an experimental "drug only" formulation. Albuterol sulfate was recovered and quantified from the device and the MT and TB regions. Significant differences in MT and total lung dose (TLD) of albuterol sulfate deposition were not observed for Salbulin Novolizer DPI and Respimat SMI inserted at different angles. In contrast, drug-only Novolizer DPI and Proventil HFA MDI showed a significant difference in MT and TLD deposition using different insertion angles. For drug-only Novolizer DPI and Proventil HFA MDI, the lowest and the highest MT depositions were observed at +10° and -20°, respectively; for Respimat SMI and Salbulin Novolizer DPI, these angles were -10° and +10°, and +20° and -20°, respectively. CFD simulations were in agreement with the experimental results and illustrated shifts in local particle deposition associated with changes in insertion angle. The effect of inhaler orientation at the inhaler-mouth interface on MT aerosol deposition appeared to be dependent on velocity, aerosol size, and formulation. These findings not only demonstrate the need for patient education on correct inhaler orientation, but provide important

  6. Outcomes in a nurse-led peripherally inserted central catheter program: a retrospective cohort study.

    Science.gov (United States)

    McDiarmid, Sheryl; Scrivens, Nicholas; Carrier, Marc; Sabri, Elham; Toye, Baldwin; Huebsch, Lothar; Fergusson, Dean

    2017-06-30

    Peripherally inserted central catheters (PICCs) provide enormous benefit to patients. However, recent publications have highlighted relatively high PICC-associated complication rates. We report on patient and device outcomes from a nurse-led program. We performed a retrospective analysis of a prospective cohort of consecutive patients undergoing PICC insertion at The Ottawa Hospital between Jan. 1, 2013 and Dec. 31, 2014. Of the 8314 BioFlo PASV PICCs inserted, we randomly selected a sample of 700 and obtained a complete data set for 656. We measured the cumulative incidence of major complications (catheter-related bloodstream infections and deep vein thrombosis) and use of a thrombolytic to alleviate occlusions. The total number of catheter days was 58 486, and the median dwell time 45 days. We observed 4 cases of catheter-related bloodstream infection (0.6% [95% CI 0.17%-1.55%]) (0.07/1000 catheter days). Ten patients (1.5% [95% CI 0.83%-2.78%]) (0.17/1000 catheter days) had catheter-related deep venous thrombosis. At least 1 dose of thrombolytic was required in 75 catheters (11.4% [95% CI 8.61%-13.39]), 31 (7.1%) of the 436 single-lumen catheters and 113 (25.7%) of the 440 lumina of dual-lumen catheters ( p < 0.001). We attribute our low rates of major complications to a nurse-led expert insertion team, standardized care and maintenance protocols, high insertion volumes, novel catheter material and continuous quality-improvement initiatives that are implemented and evaluated regularly. We conclude that the considerable benefits PICCs provide to patients are attained with a low risk of major complications. Copyright 2017, Joule Inc. or its licensors.

  7. Postplacental insertion of the levonorgestrel intrauterine device after cesarean delivery vs. delayed insertion: a randomized controlled trial.

    Science.gov (United States)

    Whitaker, Amy K; Endres, Loraine K; Mistretta, Stephanie Q; Gilliam, Melissa L

    2014-06-01

    This trial was designed to compare levonorgestrel intrauterine device (LNG-IUD) use at 1 year after delivery between women randomized to postplacental insertion at the time of cesarean delivery and delayed insertion 4-8 weeks after delivery. This randomized controlled trial was conducted at two urban medical centers. Eligible pregnant women with planned cesarean deliveries were randomized to immediate postplacental insertion during cesarean or delayed insertion after 4-8 weeks. We used intention-to-treat analysis for the primary outcome of LNG-IUD use 12 months after delivery. Forty-two women were randomized, 20 into the postplacental group and 22 in the delayed group. Although confirmed use of the LNG-IUD 12 months after delivery was higher in the postplacental group (60.0% vs. 40.9%, p=.35), this difference was not statistically significance. Expulsion was significantly more common in the postplacental group (20.0% vs. 0%, p=.04). There were significant differences between the two sites in baseline population characteristics, follow-up and expulsion. The trial did not answer the intended question as it was halted early due to slow enrollment. Our results show higher expulsion after postplacental insertion compared to delayed insertion but suggest similar IUD use at 12 months. Moreover, it provides valuable lessons regarding a randomized controlled trial of postplacental LNG-IUD placement due to the challenges of estimating effect size and the nature of the population who might benefit from immediate insertion. Postplacental insertion of an IUD may improve use of highly effective contraception during the postpartum period. While our results suggest higher expulsion after postplacental insertion compared to delayed insertion and similar IUD use at 12 months, our trial was insufficient to definitively test our hypothesis. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. The insertion products of 2-picolyl lithium salt with benzonitrile and terephthalonitrile

    Science.gov (United States)

    Zhang, Yihao; Xiao, Xia; Bai, Jianliang; Cao, Wei; Chen, Xia

    2018-02-01

    Treatment of 2-picoline with BunLi in THF affords its corresponding 2-picolyl lithium salt in a high yield. The insertion of benzonitrile into the Lisbnd C bond of 2-picolyl lithium followed by acidic hydrolysis yields the corresponding β-pyridyl ketone (1), and diketone compounds (2) is obtained from 1 by intermolecular elimination of proton under the base condition. Similarly, the insertion of terephthalonitrile into 2-picolyl lithium leads to a 1,4-phenyl-linked pyridyl-azaalyl dilithium complex 4, followed by acidic hydrolysis yields corresponding 1,4-phenyl-linked dipyridylketone 3. The probable reaction pathway for the formation of 2 has been investigated. Compound 2 and 4 have been characterized by single-crystal X-ray crystallography.

  9. Predicting painful or difficult intrauterine device insertion in nulligravid women.

    Science.gov (United States)

    Kaislasuo, Janina; Heikinheimo, Oskari; Lähteenmäki, Pekka; Suhonen, Satu

    2014-08-01

    To assess the relationship of preinsertion vaginal ultrasound assessment and menstrual and gynecologic history as predictors of difficult or painful intrauterine device insertion in nulligravid women. Nulligravid women seeking contraception were invited to participate in this nonrandomized study and given the choice between the levonorgestrel-releasing intrauterine system or a copper-releasing intrauterine device. All 165 enrolled women were interviewed and a pelvic examination, including vaginal ultrasonography, was performed before insertion. Insertion difficulties and pain intensity were recorded and assessed against uterine measurements and background characteristics. Most insertions were assessed as easy (n=144 [89.4%]) and only two (1.2%) failed. Most women had uterine measurements smaller than the studied devices. Odds for difficulties at insertion decreased with every increasing millimeter in total uterine length (odds ratio [OR] 0.86, 95% confidence interval [CI] 0.78-0.96, P=.006) and cervical length (OR 0.85, 95% CI 0.74-0.97, P=.02) and similarly with every decreasing degree of (straighter) flexion angle (OR 0.96, 95% CI 0.94-0.99, P=.005). No absolute threshold measurements could be determined. Still, the majority of insertions in small and flexed uteri were uneventful. Severe insertion pain was common (n=94 [58.4%]). Severe dysmenorrhea was the only predictor of insertion pain (OR 8.16 95% CI 2.56-26.02, P<.001). Ultrasonographic evaluation does not give additional information compared with clinical pelvic examination and sound measure. Although smaller uterine length measurements and steeper flexion angle more often predicted difficulties, the majority of insertions were uneventful in women with small measures. Dysmenorrhea was the only predictor of pain. ClinicalTrials.gov, www.clinicaltrials.gov, NCT01685164. II.

  10. Redefining Zone II: Anatomy of the Flexor Digitorum Superficialis Insertion.

    Science.gov (United States)

    Nicholson, Luke T; Hill, Jeffrey R; McKnight, Braden; Heckmann, Nathanael; Stevanovic, Milan; Ghiassi, Alidad

    2017-10-01

    Flexor zone II is defined as the region spanning the proximal aspect of the A1 pulley to the insertion of the flexor digitorum superficialis (FDS) tendon. Descriptions of the FDS insertion are inconsistent in the literature, but zones of injury are frequently determined with reference to superficial landmarks. The purpose of this study was to describe the footprint of the FDS insertion and define its relationship to the proximal interphalangeal (PIP) skin crease. The FDS insertion on the index, middle, ring, and small fingers was dissected in 6 matched pairs of fresh-frozen cadaveric hands. A Kirschner wire was used to mark the level of the PIP skin crease on bone before measurements of the FDS footprint and its position relative to the PIP skin crease were made using digital calipers. The radial and ulnar FDS slips inserted a mean distance of 3.22 mm from the distal aspect of the PIP skin crease and varied by digit. The mean distal extent of the FDS insertion was 8.29 mm. The mean length of the insertion of each FDS slip was 5.15 mm and the mean width was 1.9 mm. The radial and ulnar FDS slips insert on average 3.22 mm distal to the PIP skin crease and vary by digit. Knowledge of the FDS insertion is clinically relevant when differentiating between flexor zone I and zone II injuries, planning surgical approaches to the finger, and in guiding patient expectations for surgery given the variability in outcome based on zone of injury.

  11. Seamless Insert-Plasmid Assembly at High Efficiency and Low Cost.

    Directory of Open Access Journals (Sweden)

    Roger M Benoit

    Full Text Available Seamless cloning methods, such as co-transformation cloning, sequence- and ligation-independent cloning (SLIC or the Gibson assembly, are essential tools for the precise construction of plasmids. The efficiency of co-transformation cloning is however low and the Gibson assembly reagents are expensive. With the aim to improve the robustness of seamless cloning experiments while keeping costs low, we examined the importance of complementary single-stranded DNA ends for co-transformation cloning and the influence of single-stranded gaps in circular plasmids on SLIC cloning efficiency. Most importantly, our data show that single-stranded gaps in double-stranded plasmids, which occur in typical SLIC protocols, can drastically decrease the efficiency at which the DNA transforms competent E. coli bacteria. Accordingly, filling-in of single-stranded gaps using DNA polymerase resulted in increased transformation efficiency. Ligation of the remaining nicks did not lead to a further increase in transformation efficiency. These findings demonstrate that highly efficient insert-plasmid assembly can be achieved by using only T5 exonuclease and Phusion DNA polymerase, without Taq DNA ligase from the original Gibson protocol, which significantly reduces the cost of the reactions. We successfully used this modified Gibson assembly protocol with two short insert-plasmid overlap regions, each counting only 15 nucleotides.

  12. Direct trocar insertion vs. Verres needle use for laparoscopic sterilization.

    Science.gov (United States)

    Borgatta, L; Gruss, L; Barad, D; Kaali, S G

    1990-09-01

    A randomized, prospective trial was designed to compare direct trocar insertion with prior peritoneal insufflation with a Verres needle for laparoscopic tubal sterilization. Direct trocar insertion resulted in fewer instrument insertions (21.8% vs. 7.8%) and use of smaller volumes of CO2 (2.67 vs. 2.32 L). Direct trocar use resulted in a decrease in operating time from 9 minutes, 40 seconds in the needle group to 7 minutes, 30 seconds in the trocar group. Minor omental injuries occurred in a small percentage of each group, while serious complications occurred once in each group.

  13. Inserting environment into the national accounting system

    International Nuclear Information System (INIS)

    del Giudice, R.

    1992-01-01

    The article is an analysis of the problem of incorporating the environment in the national accounting system as an essential part of a country's revenue. Revenue is defined here as the value which is necessary for the prudent management of a nation's expenses and balances. After a first analysis of the importance of properly structuring national accounting systems, methods used in certain countries such as France, Japan and Germany were considered in order to single out the limitations and merits of these methods. The purpose is to find a standard method which would allow for comparison with the situation in various countries and, in this way, indicate directives for better management of the environment in all of its aspects

  14. Optics Solutions for the Collimation Insertion of LHC

    CERN Document Server

    Craddock, M K; Servranckx, R V; Luccio, A U; MacKay, W W

    1999-01-01

    While the two collimation insertions in the LHC must have similar basic layouts and match to almost identical dispersion suppressors to respect the geometry of the existing tunnel, their different roles impose opposite requirements on the normalized dispersion within them. For betatron collimation it must be near zero, while for momentum collimation it must have a peak at the location of the primary collimator, immediately after the dispersion suppressor. The insertion lattice solution found for the latter case requires up to 30% asymmetry in the quadrupole gradients (in line with the current trend in LHC lattice development to break the exact antisymmetry within insertions). To achieve this using twin-aperture warm quadrupoles, the modules making up each quadrupole will be wired in such a way that the two beams still see the same sequence of focusing fields. We describe the optimum setup, exibility and collimation quality for the two insertions.

  15. Laparoscopic insertion of lumbar peritoneal shunts for idiopathic ...

    African Journals Online (AJOL)

    Background: The treatment of idiopathic intracranial hypertension varies from simple observation to the mechanical diversion of cerebrospinal fluid. Objective: To describe our technique and initial experience with the laparoscopic insertion of lumbarperitoneal shunts. Conclusion: Lumbarperitoneal shunts should be ...

  16. Net-bottom Cage Inserts for Water Bird Casualties

    Directory of Open Access Journals (Sweden)

    Jackie Belle

    2017-10-01

    Full Text Available My Bright Idea is a net-bottomed cage insert, which is used to support pelagic avian casualties. The idea was designed and modified by the International Bird Rescue in California (Bird Rescue.

  17. Automatic needle insertion diminishes pain during growth hormone injection

    DEFF Research Database (Denmark)

    Main, K M; Jørgensen, J T; Hertel, N T

    1995-01-01

    Non-compliance in children receiving growth hormone (GH) treatment is often caused by pain on injection and difficulties in administration of GH. It has been suggested that automatic needle insertion diminishes pain perception. We quantitatively measured pain intensity on injection with two...... prototype pens for GH administration, providing either manual or automatic sc needle insertion, using a combined visual analogue/facial scale and a five-item scale in 18 children. With the automatic pen there was a significantly lower maximum pain score compared with the manual pen (median 28.5 versus 52.......0 mm) as well as a lower mean pain score (mean 13.7 versus 23.5 mm). The five-item scale revealed that automatic needle insertion was significantly less painful than manual insertion and 13 patients chose to continue treatment with the automatic pen. In conclusion, pain during GH injection can...

  18. Insertion device magnet measurements for the Advanced Light Source

    International Nuclear Information System (INIS)

    Marks, S.; Cork, C.; Hoyer, E.; Humphries, D.; Kincaid, B.; Plate, D.; Robb, A.; Schlueter, R.; Wang, C.; Hassenzahl, W.

    1993-05-01

    Allowable magnetic field errors for the 4.6 m long insertion devices for the Advanced Light Source (ALS) are extremely small and are driven by electron beam and radiation requirements. Detailed measurements and adjustments of each insertion device are performed to qualify them for installation in the ALS. To accomplish this, a high speed, precision magnetic measurement facility has been designed and built. Hall probe mapping equipment, capable of completing a 2500 sample, 6 m scan with precision axial position monitoring using a laser interferometer in under one minute, is used to obtain both local and integrated field information. A 5.5 m long, 1 cm wide coil is used to measure the field integral through an entire insertion device. This paper describes magnetic measurement equipment, and results of measurements on IDA, the first of the ALS insertion devices

  19. Blind bedside insertion of small bowel feeding tubes.

    LENUS (Irish Health Repository)

    Duggan, SN

    2009-12-01

    The use of Naso-Jejunal (NJ) feeding is limited by difficulty in feeding tube placement. Patients have traditionally required transfer to Endoscopy or Radiology for insertion of small bowel feeding tubes, with clear resource implications. We hypothesised that the adoption of a simple bedside procedure would be effective and reduce cost. Clinical nutrition and nurse specialist personnel were trained in the 10\\/10\\/10 method of blind bedside NJ insertion.

  20. Pen needle design influences ease of insertion, pain, and skin trauma in subjects with type 2 diabetes

    DEFF Research Database (Denmark)

    Præstmark, Kezia A; Jensen, Morten L; Berg Madsen, Nils

    2016-01-01

    subject and in random order. Penetration force (PF) through the skin, pain perception on 100 mm visual analog scale, and change in skin blood perfusion (SBP) were quantified after the insertions. RESULTS: Needle diameter was positively related to PF and SBP (ptrend relation...... of insertion, pain and skin trauma. RESEARCH DESIGN AND METHODS: 30 subjects with injection-treated type 2 diabetes and body mass index 25-35 kg/m(2) were included in the single-blinded study. Each subject received abdominal insertions with 18 different types of needles. All needles were tested twice per....... Lack of needle lubrication and small 'needle hooks' increased PF and SBP (pskin and in polyurethane rubber were linearly related, and pain outcome...

  1. Cervical Lidocaine for IUD Insertional Pain: a Randomized Controlled Trial

    Science.gov (United States)

    McNicholas, Colleen P.; Madden, Tessa; Zhao, Qiuhong; Secura, Gina; Allsworth, Jenifer E.; Peipert, Jeffrey F.

    2012-01-01

    Objective Anticipated pain with intrauterine device (IUD) insertion may be a barrier to widespread use. Our objective was to evaluate the efficacy of intracervical 2% lidocaine gel for pain relief with IUD insertion. Study Design We performed a double-blind, randomized controlled trial of women undergoing IUD insertion. Participants were randomly assigned to 2% lidocaine or placebo gel. Study gel (3ccs) wase placed 3 minutes prior to IUD insertion. Pain scores were measured at various time points using a 10-point visual analog scale. Results Of the 200 participants randomized, 199 completed the study. Pain scores among lidocaine and placebo arms were similar at tenaculum placement (lidocaine and placebo; median 4, range 0–10 p=0.15) as well as with insertion (lidocaine: median 5 range 1–10, placebo: median 6 range 0–10 p=0.16). These results did not differ by parity. Conclusions Topical or intracervical 2% lidocaine gel prior to IUD insertion does not decrease pain scores. PMID:23107081

  2. A new specifically designed forceps for chest drain insertion.

    LENUS (Irish Health Repository)

    Andrews, Emmet

    2012-02-03

    Insertion of a chest drain can be associated with serious complications. It is recommended that the drain is inserted with blunt dissection through the chest wall but there is no specific instrument to aid this task. We describe a new reusable forceps that has been designed specifically to facilitate the insertion of chest drains.A feasibility study of its use in patients who required a chest drain as part of elective cardiothoracic operations was undertaken. The primary end-point was successful and accurate placement of the drain. The operators also completed a questionnaire rating defined aspects of the procedure. The new instrument was used to insert the chest drain in 30 patients (19 male, 11 female; median age 61.5 years (range 16-81 years)). The drain was inserted successfully without the trocar in all cases and there were no complications. Use of the instrument rated as significantly easier relative to experience of previous techniques in all specified aspects. The new device can be used to insert intercostal chest drains safely and efficiently without using the trocar or any other instrument.

  3. Descriptive anatomy of the insertion of the biceps femoris muscle.

    Science.gov (United States)

    Tubbs, R Shane; Caycedo, Francisco J; Oakes, W Jerry; Salter, E George

    2006-09-01

    The biceps femoris is the most lateral component of the so-called hamstring muscles. Classically, this muscle's insertion into the head of the fibula has been described but further details of its anatomy have not been universally appreciated. Additional insertions into the crural fascia and tibia have been described. We dissected 56 cadavers paying especially close attention to the insertion of the biceps femoris muscle. The tendon of this muscle was found to have both medial and lateral slips each with an anterior and posterior component. Further, we found an attachment not only into the lateral condyle of the femur but also the popliteus tendon and arcuate popliteal ligament. Our study has found that the tendon of insertion of the biceps femoris muscle is more complex than described previously and suggests that this tendon may be far more important in knee stability based on the multiple attachment sites found. We hypothesize that there may be a synergistic effect between the biceps femoris and the popliteus muscles based on our findings of an additional attachment of the biceps femoris tendon into the popliteus tendon. This study provides new detailed nomenclature for the description of the tendon of insertion of the biceps femoris muscle and indicates that the current description of the insertion of the tendon of the biceps femoris muscle should be revised. The clinician must have a thorough understanding of this anatomy before correct therapeutic maneuvers can be implemented.

  4. Postplacental intrauterine device insertion at a teaching hospital.

    Science.gov (United States)

    Jatlaoui, Tara C; Marcus, Michele; Jamieson, Denise J; Goedken, Peggy; Cwiak, Carrie

    2014-06-01

    To determine whether postplacental intrauterine device (IUD) insertion can be safely and effectively performed within a teaching program. This was a prospective cohort of 177 subjects planning vaginal delivery enrolled antenatally who desired postplacental IUD insertion of either the copper T380A IUD or levonorgestrel IUS. Insertions were performed primarily by resident physicians following a training session. Follow-up included a 4- to 8-week visit and telephone calls at 3 and 6 months. Ninety-nine subjects underwent successful postplacental IUD insertion of 100 attempts. Seventeen expulsions (17%) were noted: 10 complete and 7 partial. The study identified no differences in outcome by training level; however, the study lacked statistical power to evaluate anything other than large differences. Postplacental IUD insertions can be safely and effectively performed within a training program. A training protocol may safely and feasibly be initiated among physicians, advanced practice clinicians or trainees with no prior experience with postplacental IUD insertion. By initiating this practice, access to highly effective contraception may increase for patients who have difficulty returning for a visit or otherwise receiving effective methods. © 2014.

  5. Templated sequence insertion polymorphisms in the human genome

    Science.gov (United States)

    Onozawa, Masahiro; Aplan, Peter

    2016-11-01

    Templated Sequence Insertion Polymorphism (TSIP) is a recently described form of polymorphism recognized in the human genome, in which a sequence that is templated from a distant genomic region is inserted into the genome, seemingly at random. TSIPs can be grouped into two classes based on nucleotide sequence features at the insertion junctions; Class 1 TSIPs show features of insertions that are mediated via the LINE-1 ORF2 protein, including 1) target-site duplication (TSD), 2) polyadenylation 10-30 nucleotides downstream of a “cryptic” polyadenylation signal, and 3) preference for insertion at a 5’-TTTT/A-3’ sequence. In contrast, class 2 TSIPs show features consistent with repair of a DNA double-strand break via insertion of a DNA “patch” that is derived from a distant genomic region. Survey of a large number of normal human volunteers demonstrates that most individuals have 25-30 TSIPs, and that these TSIPs track with specific geographic regions. Similar to other forms of human polymorphism, we suspect that these TSIPs may be important for the generation of human diversity and genetic diseases.

  6. Phylogenetic Conflict in Bears Identified by Automated Discovery of Transposable Element Insertions in Low-Coverage Genomes

    Science.gov (United States)

    Gallus, Susanne; Janke, Axel

    2017-01-01

    Abstract Phylogenetic reconstruction from transposable elements (TEs) offers an additional perspective to study evolutionary processes. However, detecting phylogenetically informative TE insertions requires tedious experimental work, limiting the power of phylogenetic inference. Here, we analyzed the genomes of seven bear species using high-throughput sequencing data to detect thousands of TE insertions. The newly developed pipeline for TE detection called TeddyPi (TE detection and discovery for Phylogenetic Inference) identified 150,513 high-quality TE insertions in the genomes of ursine and tremarctine bears. By integrating different TE insertion callers and using a stringent filtering approach, the TeddyPi pipeline produced highly reliable TE insertion calls, which were confirmed by extensive in vitro validation experiments. Analysis of single nucleotide substitutions in the flanking regions of the TEs shows that these substitutions correlate with the phylogenetic signal from the TE insertions. Our phylogenomic analyses show that TEs are a major driver of genomic variation in bears and enabled phylogenetic reconstruction of a well-resolved species tree, despite strong signals for incomplete lineage sorting and introgression. The analyses show that the Asiatic black, sun, and sloth bear form a monophyletic clade, in which phylogenetic incongruence originates from incomplete lineage sorting. TeddyPi is open source and can be adapted to various TE and structural variation callers. The pipeline makes it possible to confidently extract thousands of TE insertions even from low-coverage genomes (∼10×) of nonmodel organisms. This opens new possibilities for biologists to study phylogenies and evolutionary processes as well as rates and patterns of (retro-)transposition and structural variation. PMID:28985298

  7. Phylogenetic Conflict in Bears Identified by Automated Discovery of Transposable Element Insertions in Low-Coverage Genomes.

    Science.gov (United States)

    Lammers, Fritjof; Gallus, Susanne; Janke, Axel; Nilsson, Maria A

    2017-10-01

    Phylogenetic reconstruction from transposable elements (TEs) offers an additional perspective to study evolutionary processes. However, detecting phylogenetically informative TE insertions requires tedious experimental work, limiting the power of phylogenetic inference. Here, we analyzed the genomes of seven bear species using high-throughput sequencing data to detect thousands of TE insertions. The newly developed pipeline for TE detection called TeddyPi (TE detection and discovery for Phylogenetic Inference) identified 150,513 high-quality TE insertions in the genomes of ursine and tremarctine bears. By integrating different TE insertion callers and using a stringent filtering approach, the TeddyPi pipeline produced highly reliable TE insertion calls, which were confirmed by extensive in vitro validation experiments. Analysis of single nucleotide substitutions in the flanking regions of the TEs shows that these substitutions correlate with the phylogenetic signal from the TE insertions. Our phylogenomic analyses show that TEs are a major driver of genomic variation in bears and enabled phylogenetic reconstruction of a well-resolved species tree, despite strong signals for incomplete lineage sorting and introgression. The analyses show that the Asiatic black, sun, and sloth bear form a monophyletic clade, in which phylogenetic incongruence originates from incomplete lineage sorting. TeddyPi is open source and can be adapted to various TE and structural variation callers. The pipeline makes it possible to confidently extract thousands of TE insertions even from low-coverage genomes (∼10×) of nonmodel organisms. This opens new possibilities for biologists to study phylogenies and evolutionary processes as well as rates and patterns of (retro-)transposition and structural variation. © The Author 2017. Published by Oxford University Press on behalf of the Society for Molecular Biology and Evolution.

  8. Insertion torque values and success rates for paramedian insertion of orthodontic mini-implants : A retrospective study.

    Science.gov (United States)

    Di Leonardo, Bruno; Ludwig, Björn; Lisson, Jörg Alexander; Contardo, Luca; Mura, Rossano; Hourfar, Jan

    2018-03-01

    Orthodontic mini-implants (OMIs) are a reliable method to provide temporary orthodontic anchorage. We hypothesized that there is an optimal insertion torque (10 Ncm) will decrease the success rate and increase palatal OMI failure was rejected.

  9. CRISPR/Cas9 cleavages in budding yeast reveal templated insertions and strand-specific insertion/deletion profiles.

    Science.gov (United States)

    Lemos, Brenda R; Kaplan, Adam C; Bae, Ji Eun; Ferrazzoli, Alexander E; Kuo, James; Anand, Ranjith P; Waterman, David P; Haber, James E

    2018-02-13

    Harnessing CRISPR-Cas9 technology provides an unprecedented ability to modify genomic loci via DNA double-strand break (DSB) induction and repair. We analyzed nonhomologous end-joining (NHEJ) repair induced by Cas9 in budding yeast and found that the orientation of binding of Cas9 and its guide RNA (gRNA) profoundly influences the pattern of insertion/deletions (indels) at the site of cleavage. A common indel created by Cas9 is a 1-bp (+1) insertion that appears to result from Cas9 creating a 1-nt 5' overhang that is filled in by a DNA polymerase and ligated. The origin of +1 insertions was investigated by using two gRNAs with PAM sequences located on opposite DNA strands but designed to cleave the same sequence. These templated +1 insertions are dependent on the X-family DNA polymerase, Pol4. Deleting Pol4 also eliminated +2 and +3 insertions, which are biased toward homonucleotide insertions. Using inverted PAM sequences, we also found significant differences in overall NHEJ efficiency and repair profiles, suggesting that the binding of the Cas9:gRNA complex influences subsequent NHEJ processing. As with events induced by the site-specific HO endonuclease, CRISPR-Cas9-mediated NHEJ repair depends on the Ku heterodimer and DNA ligase 4. Cas9 events are highly dependent on the Mre11-Rad50-Xrs2 complex, independent of Mre11's nuclease activity. Inspection of the outcomes of a large number of Cas9 cleavage events in mammalian cells reveals a similar templated origin of +1 insertions in human cells, but also a significant frequency of similarly templated +2 insertions.

  10. [Ultrasound-guided peripherally inserted central catheters (PICC) in cancer patients: success of the insertion, survival and complications].

    Science.gov (United States)

    Moraza-Dulanto, Maria Inmaculada; Garate-Echenique, Lucía; Miranda-Serrano, Erika; Armenteros-Yeguas, Victoria; Tomás-López, María Aranzazu; Benítez-Delgado, Beatriz

    2012-01-01

    To evaluate the results of peripherally inserted central catheters (PICC) inserted by nurses using an ultrasound-guided technique at bed-side. An observational and prospective study was conducted on all the PICC inserted at bed-side by an ultrasound-guided technique at the Araba University Hospital. The technique was introduced in June 2010, and the data collection period ended in November 2011. The main study variables were successful insertion, duration of PICC, incidences related to the catheter, devices reaching end of treatment and reasons for withdrawal. Patient sociodemographic data and PICC technical features were also registered. A total of 165 PICC were inserted, 73 are still in use, with 95.2% inserted in patients from oncology or haematology departments. Insertion was successful in the 89.7% (95% CI: 85.1%-94.3%) of the cases. The study included 16,234 catheter days, with a median dwell time of 92 days by PICC. The most frequent incidence was accidental removal in 0.986 per 1000 catheter days (95% CI=0.970-1.001). The thrombosis rate was 0.308 per 1,000 days (95% CI= 0.299-0.317), and the catheter-associated bloodstream infection rate was 0.062 per 1,000 catheter days (95% CI=0.058-0.065). Ultrasound-guided PICC insertion can be performed at bedside by trained nurses with a high probability of success. PICC, because of its low complication rate and long indwelling catheter survival, is a suitable central venous device for long-term treatment in oncology and haematology patients. Copyright © 2011 Elsevier España, S.L. All rights reserved.

  11. LiPS-A3S, a human genomic site for robust expression of inserted transgenes

    Directory of Open Access Journals (Sweden)

    Andriana G Kotini

    2016-01-01

    Full Text Available Transgenesis of human pluripotent stem cells (hPSCs can enable and empower a variety of studies in stem cell research, including lineage tracing and functional genetics studies. While in recent years much progress has been made in the development of tools for gene targeting, little attention has been given to the identification of sites in the human genome where transgenes can be inserted and reliably expressed. In order to find human genomic sites capable of supporting long-term and high-level transgene expression in hPSCs, we performed a lentiviral screen in human induced pluripotent stem cells (iPSCs. We isolated 40 iPSC clones each harboring a single vector copy and characterized the level of transgene expression afforded by each unique integration site. We selected one clone, LiPS-A3 with an integration site in chromosome 15 maintaining robust expression without silencing and demonstrate that different transgenes can be inserted therein rapidly and efficiently through recombinase-mediated cassette exchange (RMCE. The LiPS-A3 line can greatly facilitate the insertion of reporter and other genes in hPSCs. Targeting transgenes in the LiPS-A3S genomic locus can find broad applications in stem cell research and possibly cell and gene therapy.

  12. Multiplex PCR screening detects small p53 deletions and insertions in human ovarian cancer cell lines.

    Science.gov (United States)

    Runnebaum, I B; Tong, X W; Moebus, V; Heilmann, V; Kieback, D G; Kreienberg, R

    1994-06-01

    Mutations at the p53 tumor suppressor gene locus are a frequent genetic alteration associated with human ovarian carcinoma. Little information exists regarding whether mutational events occur other than point mutations and large deletions, causing loss of heterozygosity. Small intragenic deletions and insertions in the p53 gene have been observed in various human neoplasias. We developed a multiplex polymerase chain reaction (MPCR) screening assay to amplify the complete p53 coding region from genomic DNA in a single step. Deletions and/or insertions were found in six out of 11 newly established ovarian carcinoma cell lines. MPCR detected deletions as small as 2 bp, as confirmed by nucleotide sequence analysis. Most of the observed alterations (6/7) were homozygous or hemizygous. Structural aberrations of the p53 gene possibly leading to loss of p53 cell cycle control may be a consequence of a slipped-mispairing mechanism in rapid DNA replication during repetitious ovulation and wound repair of ovarian epithelial cells. MPCR may be a valuable tool for screening for possible p53 deletion and insertion mutations not only in ovarian cancer but also in other malignancies.

  13. Additional Analgesia for Central Venous Catheter Insertion: A Placebo Controlled Randomized Trial of Dexmedetomidine and Fentanyl

    Directory of Open Access Journals (Sweden)

    Aloka Samantaray

    2016-01-01

    Full Text Available We aimed to show that a single preprocedural dose of either dexmedetomidine or fentanyl reduces procedural pain and discomfort and provides clinically acceptable sedation. In this prospective, double-blind study, sixty patients scheduled for elective surgery and requiring planned central venous catheter insertion were randomized to receive dexmedetomidine (1 μg/kg, fentanyl (1 μg/kg, or 0.9% normal saline intravenously over ten minutes followed by local anesthetic field infiltration before attempting central venous catheterization. The primary outcome measures are assessment and analysis of pain, discomfort, and sedation level before, during, and after the central venous catheter insertion at five time points. The median (IQR pain score is worst for normal saline group at local anaesthetic injection [6 (4–6.7] which was significantly attenuated by addition of fentanyl [3 (2–4] and dexmedetomidine [4 (3–5] in the immediate postprocedural period (P=0.001. However, the procedure related discomfort was significantly lower in dexmedetomidine group compared to fentanyl group in the first 10 min of procedure after local anaesthetic Injection (P=0.001. Fentanyl is more analgesically efficient for central venous catheter insertion along with local anaesthetic injection. However, dexmedetomidine has the potential to be superior to fentanyl and placebo in terms of providing comfort to the patients during the procedure.

  14. Novel insertion mutation of ABCB1 gene in an ivermectin-sensitive Border Collie.

    Science.gov (United States)

    Han, Jae-Ik; Son, Hyoung-Won; Park, Seung-Cheol; Na, Ki-Jeong

    2010-12-01

    P-glycoprotein (P-gp) is encoded by the ABCB1 gene and acts as an efflux pump for xenobiotics. In the Border Collie, a nonsense mutation caused by a 4-base pair deletion in the ABCB1 gene is associated with a premature stop to P-gp synthesis. In this study, we examined the full-length coding sequence of the ABCB1 gene in an ivermectin-sensitive Border Collie that lacked the aforementioned deletion mutation. The sequence was compared to the corresponding sequences of a wild-type Beagle and seven ivermectin-tolerant family members of the Border Collie. When compared to the wild-type Beagle sequence, that of the ivermectin-sensitive Border Collie was found to have one insertion mutation and eight single nucleotide polymorphisms (SNPs) in the coding sequence of the ABCB1 gene. While the eight SNPs were also found in the family members' sequences, the insertion mutation was found only in the ivermectin-sensitive dog. These results suggest the possibility that the SNPs are species-specific features of the ABCB1 gene in Border Collies, and that the insertion mutation may be related to ivermectin intolerance.

  15. Insertion Process of Ceramic Nanoporous Microneedles by Means of a Novel Mechanical Applicator Design

    Directory of Open Access Journals (Sweden)

    Xavier H. M. Hartmann

    2015-11-01

    Full Text Available Arrays of microneedles (MNAs are integrated in an out-of-plane fashion with a base plate and can serve as patches for the release of drugs and vaccines. We used soft-lithography and micromolding to manufacture ceramic nanoporous (npMNAs. Failure modes of ceramic npMNAs are as yet poorly understood and the question remained: is our npMNA platform technology ready for microneedle (MN assembly into patches? We investigated npMNAs by microindentation, yielding average crack fracture forces above the required insertion force for a single MN to penetrate human skin. We further developed a thumb pressure-actuated applicator-assisted npMNA insertion method, which enables anchoring of MNs in the skin by an adhesive in one handling step. Using a set of simple artificial skin models, we found a puncture efficiency of this insertion method a factor three times higher than by applying thumb pressure on the npMNA base plate directly. In addition, this new method facilitated zero MN-breakage due to a well-defined force distribution exerted onto the MNs and the closely surrounding area prior to bringing the adhesive into contact with the skin. Owing to the fact that such parameter space exists, we can conclude that npMNAs by soft lithography are a platform technology for MN assembly into a patch.

  16. Facial asymmetry and clinical manifestations in patients with novel insertion of the TCOF1 gene.

    Science.gov (United States)

    Su, P-H; Liu, Y-F; Yu, J-S; Chen, J-Y; Chen, S-J; Lai, Y-J

    2012-11-01

    This study explored the role of TCOF1 insertion mutations in Taiwanese patients with craniofacial anomalies. Twelve patients with single or multiple, asymmetrical congenital craniofacial anomalies were enrolled. Genomic DNA was prepared from leukocytes; the coding regions of TCOF1 were analyzed by polymerase chain reaction and direct sequencing. Clinical manifestations were correlated to the TCOF1 mutation. Six of 12 patients diagnosed with hemifacial microsomia exhibited a novel insertion mutation 4127 ins G (frameshift) in exon 24 in the TCOF1 gene. All six patients were diagnosed with anomalies on the left side. In addition, four of these six patients had hearing impairment; three had other major anomalies; and two had developmental delay. The insertion caused a frameshift, an early truncation, the loss of two putative nuclear localization signals (residues 1404-1420 and 1424-1440), and the loss of coiled coil domain (1406-1426) in treacle protein. These findings support the existence of two regulators of growth of the mandibular condyles. © 2011 John Wiley & Sons A/S.

  17. Laparoscopic versus open peritoneal dialysis catheter insertion, the LOCI-trial: a study protocol

    Directory of Open Access Journals (Sweden)

    Hagen Sander M

    2011-12-01

    Full Text Available Abstract Background Peritoneal dialysis (PD is an effective treatment for end-stage renal disease. It allows patients more freedom to perform daily activities compared to haemodialysis. Key to successful PD is the presence of a well-functioning dialysis catheter. Several complications, such as in- and outflow obstruction, peritonitis, exit-site infections, leakage and migration, can lead to catheter removal and loss of peritoneal access. Currently, different surgical techniques are in practice for PD-catheter placement. The type of insertion technique used may greatly influence the occurrence of complications. In the literature, up to 35% catheter failure has been described when using the open technique and only 13% for the laparoscopic technique. However, a well-designed randomized controlled trial is lacking. Methods/Design The LOCI-trial is a multi-center randomized controlled, single-blind trial (pilot. The study compares the laparoscopic with the open technique for PD catheter insertion. The primary objective is to determine the optimum placement technique in order to minimize the incidence of catheter malfunction at 6 weeks postoperatively. Secondary objectives are to determine the best approach to optimize catheter function and to study the quality of life at 6 months postoperatively comparing the two operative techniques. Discussion This study will generate evidence on any benefits of laparoscopic versus open PD catheter insertion. Trial registration Dutch Trial Register NTR2878

  18. Design, Fabrication and Testing of an Insertable Double-Imaging-Region Gradient Coil.

    Science.gov (United States)

    Goodrich, K Craig; Hadley, J Rock; Moon, Sung M; Chronik, Blaine A; Scholl, Timothy J; Debever, Joshua T; Parker, Dennis L

    2009-04-01

    We have constructed a small-bore insertable gradient coil with two linear gradient imaging regions and interfaced it with an MRI scanner. We have also constructed an RF system capable of transmitting or receiving in both regions simultaneously.Designs for conductor placement for two-region X-, Y- and Z-gradient coils were optimized by simulated annealing. Wire patterns for each axis were chosen that gave low inductance, reasonable homogeneity over a large imaging volume and high efficiency (gradient field per-unit-current).Imaging was performed on a Siemens 3T TIM Trio scanner equipped with three additional gradient amplifier channels and a second RF/gradient array controller. Phantoms were placed in the two imaging regions as well as the central non-imaging region to test gradient homogeneity and crosstalk between regions. Images acquired simultaneously in the two regions showed very little signal crosstalk between imaging regions and even less signal from the central, non-imaging region.When combined with an overlapping single-region gradient insert, extended field-of-view (FOV) imaging will be possible without moving the table or the subject and without increasing nerve stimulation. Construction and testing of a two-region gradient coil insert is a necessary intermediate step as a proof of concept for an extended field of view, contiguous, three-region human-sized gradient system.

  19. Effect of vaginal administration of misoprostol before intrauterine contraceptive insertion following previous insertion failure: a double blind RCT.

    Science.gov (United States)

    Bahamondes, M Valeria; Espejo-Arce, Ximena; Bahamondes, Luis

    2015-08-01

    Is pretreatment with misoprostol useful in insertion of intrauterine contraceptives (IUCs) after insertion failure at the first attempt? Pretreatment with intravaginal administration of 200 mcg of misoprostol after IUC insertion failure 10 and 4 h before the second attempt of IUC placement was significantly better than placebo at facilitating the insertion of an IUC. One of the reasons for low use of IUCs is the concept that insertion is difficult. Misoprostol was used in several randomized clinical trials (RCT) before IUC insertion to facilitate the insertion. In general, the results showed no significant differences when compared with placebo. However, most previous studies have been carried out among unselected women whereas the present study is among women with previous insertion failure. This was a double blind RCT conducted between February 2013 and October 2014. Participants were 104 women who requested an insertion of an IUC and the insertion failed at the first attempt. After insertion failure, the women received a sealed envelope with misoprostol or placebo. The randomization system (1: 1) in one block size was computer-generated. The study was conducted at a tertiary care centre. The women were instructed to insert vaginally one tablet of misoprostol 200 µg (Prostokos, Hebron, Cariacica, PE, Brazil) or placebo 10 and 4 h before the woman returned to the clinic for a new insertion attempt. The outcomes were successful IUC insertion and the use of a cervical dilator immediately prior to the insertion procedure. A total of 2639 women requested the insertion of an IUC during the study period. The IUC was inserted at the first attempt in 2535 women (96%) and 104 women in whom we were unable to insert the device were eligible to participate in the RCT. Four women declined and 100 women were randomized (55 for the misoprostol group and 45 for the placebo group). From the 100 participating women, the levonorgestrel-releasing intrauterine system (LNG-IUS) was

  20. Insertional inactivation of a chromosomal locus that modulates expression of potential virulence determinants in Staphylococcus aureus.

    OpenAIRE

    Cheung, A L; Wolz, C; Yeaman, M R; Bayer, A S

    1995-01-01

    A single insertion of transposon Tn551 into a unique chromosomal locus of Staphylococcus aureus ISP479C has resulted in a pleiotropic effect on the expression of both extracellular and cell wall proteins. In particular, the expression of cell wall protein A and clumping activity with fibrinogen were rendered undetectable in the mutant 1E3 compared with the parent. The secretion of alpha-hemolysin in mutant 1E3 was modestly increased. Southern blot and phenotypic analyses indicated that this l...

  1. Methanol Formation via Oxygen Insertion Chemistry in Ices

    International Nuclear Information System (INIS)

    Bergner, Jennifer B.; Öberg, Karin I.; Rajappan, Mahesh

    2017-01-01

    We present experimental constraints on the insertion of oxygen atoms into methane to form methanol in astrophysical ice analogs. In gas-phase and theoretical studies this process has previously been demonstrated to have a very low or nonexistent energy barrier, but the energetics and mechanisms have not yet been characterized in the solid state. We use a deuterium UV lamp filtered by a sapphire window to selectively dissociate O 2 within a mixture of O 2 :CH 4 and observe efficient production of CH 3 OH via O( 1 D) insertion. CH 3 OH growth curves are fit with a kinetic model, and we observe no temperature dependence of the reaction rate constant at temperatures below the oxygen desorption temperature of 25 K. Through an analysis of side products we determine the branching ratio of ice-phase oxygen insertion into CH 4 : ∼65% of insertions lead to CH 3 OH, with the remainder leading instead to H 2 CO formation. There is no evidence for CH 3 or OH radical formation, indicating that the fragmentation is not an important channel and that insertions typically lead to increased chemical complexity. CH 3 OH formation from O 2 and CH 4 diluted in a CO-dominated ice similarly shows no temperature dependence, consistent with expectations that insertion proceeds with a small or nonexistent barrier. Oxygen insertion chemistry in ices should therefore be efficient under low-temperature ISM-like conditions and could provide an important channel to complex organic molecule formation on grain surfaces in cold interstellar regions such as cloud cores and protoplanetary disk midplanes.

  2. Methanol Formation via Oxygen Insertion Chemistry in Ices

    Science.gov (United States)

    Bergner, Jennifer B.; Öberg, Karin I.; Rajappan, Mahesh

    2017-08-01

    We present experimental constraints on the insertion of oxygen atoms into methane to form methanol in astrophysical ice analogs. In gas-phase and theoretical studies this process has previously been demonstrated to have a very low or nonexistent energy barrier, but the energetics and mechanisms have not yet been characterized in the solid state. We use a deuterium UV lamp filtered by a sapphire window to selectively dissociate O2 within a mixture of O2:CH4 and observe efficient production of CH3OH via O(1D) insertion. CH3OH growth curves are fit with a kinetic model, and we observe no temperature dependence of the reaction rate constant at temperatures below the oxygen desorption temperature of 25 K. Through an analysis of side products we determine the branching ratio of ice-phase oxygen insertion into CH4: ˜65% of insertions lead to CH3OH, with the remainder leading instead to H2CO formation. There is no evidence for CH3 or OH radical formation, indicating that the fragmentation is not an important channel and that insertions typically lead to increased chemical complexity. CH3OH formation from O2 and CH4 diluted in a CO-dominated ice similarly shows no temperature dependence, consistent with expectations that insertion proceeds with a small or nonexistent barrier. Oxygen insertion chemistry in ices should therefore be efficient under low-temperature ISM-like conditions and could provide an important channel to complex organic molecule formation on grain surfaces in cold interstellar regions such as cloud cores and protoplanetary disk midplanes.

  3. Methanol Formation via Oxygen Insertion Chemistry in Ices

    Energy Technology Data Exchange (ETDEWEB)

    Bergner, Jennifer B. [Harvard University Department of Chemistry and Chemical Biology, 10 Oxford Street, Cambridge, MA 02138 (United States); Öberg, Karin I.; Rajappan, Mahesh [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States)

    2017-08-10

    We present experimental constraints on the insertion of oxygen atoms into methane to form methanol in astrophysical ice analogs. In gas-phase and theoretical studies this process has previously been demonstrated to have a very low or nonexistent energy barrier, but the energetics and mechanisms have not yet been characterized in the solid state. We use a deuterium UV lamp filtered by a sapphire window to selectively dissociate O{sub 2} within a mixture of O{sub 2}:CH{sub 4} and observe efficient production of CH{sub 3}OH via O({sup 1}D) insertion. CH{sub 3}OH growth curves are fit with a kinetic model, and we observe no temperature dependence of the reaction rate constant at temperatures below the oxygen desorption temperature of 25 K. Through an analysis of side products we determine the branching ratio of ice-phase oxygen insertion into CH{sub 4}: ∼65% of insertions lead to CH{sub 3}OH, with the remainder leading instead to H{sub 2}CO formation. There is no evidence for CH{sub 3} or OH radical formation, indicating that the fragmentation is not an important channel and that insertions typically lead to increased chemical complexity. CH{sub 3}OH formation from O{sub 2} and CH{sub 4} diluted in a CO-dominated ice similarly shows no temperature dependence, consistent with expectations that insertion proceeds with a small or nonexistent barrier. Oxygen insertion chemistry in ices should therefore be efficient under low-temperature ISM-like conditions and could provide an important channel to complex organic molecule formation on grain surfaces in cold interstellar regions such as cloud cores and protoplanetary disk midplanes.

  4. Anatomy and dimensions of the gluteus medius tendon insertion.

    Science.gov (United States)

    Robertson, William J; Gardner, Michael J; Barker, Joseph U; Boraiah, Sreevathsa; Lorich, Dean G; Kelly, Bryan T

    2008-02-01

    The purpose of this study was to determine the area, dimensions, and orientation of the gluteus medius footprint to provide an improved understanding of its insertional anatomy. Eight fresh-frozen cadaveric hips were dissected, leaving only the most distal gluteus medius tendon attached to the greater trochanter. The tendon insertion footprint and proximal femur were digitized and mapped by use of 3-dimensional computer navigation software. The area, location, and dimensions of the tendon insertion were determined. The gluteus medius tendon has 2 distinct insertion sites on the greater trochanter, the lateral facet and the superoposterior facet. The mean areas of insertion onto the lateral and superoposterior facets were 438.0 mm2 (SD, 57.7 mm2) and 196.5 mm2 (SD, 48.4 mm2), respectively. The lateral facet footprint had a mean longitudinal dimension of 34.8 mm (SD, 4.3 mm), was angled at a mean of 36.8 degrees (SD, 6.7 degrees ) relative to the long axis of the femur, and had a mean minimum width of 11.2 mm (SD, 1.8 mm). The superoposterior facet's shape approximated that of a circle, with a mean diameter of 17 mm (SD, 2.0 mm). The gluteus medius tendon has 2 distinct and consistent insertion sites onto the greater trochanter. This information will provide surgeons with a better understanding of the footprint anatomy when evaluating gluteus medius tendon tears. Gluteus medius tendon tears can be a source of significant pain and morbidity. This study describes the anatomic morphology of this tendon insertion, which should aid in its repair when necessary.

  5. Effect of fiber insertion depth on antibacterial efficacy of photodynamic therapy against Enterococcus faecalis in rootcanals.

    Science.gov (United States)

    Rödig, Tina; Endres, Sarah; Konietschke, Frank; Zimmermann, Ortrud; Sydow, Hans Georg; Wiegand, Annette

    2017-06-01

    This in vitro study evaluated the effect of fiber insertion depth on antimicrobial efficacy of antimicrobial photodynamic therapy (aPDT) using a photosensitizer (PS; toluidine blue) and a red light-emitting diode (LED) in root canals infected with Enterococcus faecalis. Single-rooted extracted teeth were prepared with nickel-titanium-instruments, sterilized, contaminated with E. faecalis, and incubated for 72 h. Roots were randomly divided into four experimental groups: PS only, LED only, aPDT with LED in the apical third, aPDT with LED in the coronal third, as well as into infection and sterile controls (each n = 10). Samples were taken by collecting standardized dentine shavings from the root canal walls. After serial dilution and culturing on blood agar, colony-forming units (CFU) were counted. Both aPDT groups showed a CFU reduction of 1-2 log 10 steps compared with the infection control, whereas the effect of fiber insertion depth was negligible (<0.5 log 10 steps). CFU reduction of approximately 0.5 log 10 steps for PS alone was detected compared with the infection control, but PS alone was less effective than both aPDT groups. No antibacterial effect was detected for LED alone. aPDT reduced E. faecalis within the root canal, whereas fiber insertion depth had a negligible influence on antimicrobial effectiveness of aPDT. The insertion depth of the light-emitting diode may not influence the antibacterial efficacy of photodynamic therapy against E. faecalis in straight root canals.

  6. The "bench-presser's shoulder": an overuse insertional tendinopathy of the pectoralis minor muscle.

    Science.gov (United States)

    Bhatia, Deepak N; de Beer, Joe F; van Rooyen, Karin S; Lam, Francis; du Toit, Donald F

    2007-08-01

    Tendinopathies of the rotator cuff muscles, biceps tendon and pectoralis major muscle are common causes of shoulder pain in athletes. Overuse insertional tendinopathy of pectoralis minor is a previously undescribed cause of shoulder pain in weightlifters/sportsmen. To describe the clinical features, diagnostic tests and results of an overuse insertional tendinopathy of the pectoralis minor muscle. To also present a new technique of ultrasonographic evaluation and injection of the pectoralis minor muscle/tendon based on use of standard anatomical landmarks (subscapularis, coracoid process and axillary artery) as stepwise reference points for ultrasonographic orientation. Between 2005 and 2006, seven sportsmen presenting with this condition were diagnosed and treated at the Cape Shoulder Institute, Cape Town, South Africa. In five patients, the initiating and aggravating factor was performance of the bench-press exercise (hence the term "bench-presser's shoulder"). Medial juxta-coracoid tenderness, a painful active-contraction test and bench-press manoeuvre, and decrease in pain after ultrasound-guided injection of a local anaesthetic agent into the enthesis, in the absence of any other clinically/radiologically apparent pathology, were diagnostic of pectoralis minor insertional tendinopathy. All seven patients were successfully treated with a single ultrasound-guided injection of a corticosteroid into the enthesis of pectoralis minor followed by a period of rest and stretching exercises. This study describes the clinical features and management of pectoralis minor insertional tendinopathy, secondary to the bench-press type of weightlifting. A new pain site-based classification of shoulder pathology in weightlifters is suggested.

  7. The “bench‐presser's shoulder”: an overuse insertional tendinopathy of the pectoralis minor muscle

    Science.gov (United States)

    Bhatia, Deepak N; de Beer, Joe F; van Rooyen, Karin S; Lam, Francis; du Toit, Donald F

    2007-01-01

    Background Tendinopathies of the rotator cuff muscles, biceps tendon and pectoralis major muscle are common causes of shoulder pain in athletes. Overuse insertional tendinopathy of pectoralis minor is a previously undescribed cause of shoulder pain in weightlifters/sportsmen. Objectives To describe the clinical features, diagnostic tests and results of an overuse insertional tendinopathy of the pectoralis minor muscle. To also present a new technique of ultrasonographic evaluation and injection of the pectoralis minor muscle/tendon based on use of standard anatomical landmarks (subscapularis, coracoid process and axillary artery) as stepwise reference points for ultrasonographic orientation. Methods Between 2005 and 2006, seven sportsmen presenting with this condition were diagnosed and treated at the Cape Shoulder Institute, Cape Town, South Africa. Results In five patients, the initiating and aggravating factor was performance of the bench‐press exercise (hence the term “bench‐presser's shoulder”). Medial juxta‐coracoid tenderness, a painful active‐contraction test and bench‐press manoeuvre, and decrease in pain after ultrasound‐guided injection of a local anaesthetic agent into the enthesis, in the absence of any other clinically/radiologically apparent pathology, were diagnostic of pectoralis minor insertional tendinopathy. All seven patients were successfully treated with a single ultrasound‐guided injection of a corticosteroid into the enthesis of pectoralis minor followed by a period of rest and stretching exercises. Conclusions This study describes the clinical features and management of pectoralis minor insertional tendinopathy, secondary to the bench‐press type of weightlifting. A new pain site‐based classification of shoulder pathology in weightlifters is suggested. PMID:17138640

  8. Clinical outcome of narrow diameter implants inserted into allografts

    Directory of Open Access Journals (Sweden)

    Maurizio Franco

    2009-08-01

    Full Text Available OBJECTIVE: Narrow diameter implants (NDI (i.e. diameter <3.75 mm are a potential solution for specific clinical situations, such as reduced interradicular bone, thin alveolar crest and replacement of teeth with small cervical diameter. NDI have been available in clinical practice since the 1990s, but only few studies have analyzed their clinical outcome and no study have investigated NDI inserted in fresh-frozen bone (FFB grafts. Thus, a retrospective study on a series of NDI placed in homologue FFB was designed to evaluate their clinical outcome. MATERIAL AND METHODS: In the period between December 2003 and December 2006, 36 patients (22 females and 14 males, mean age 53 years with FFB grafts were selected and 94 different NDI were inserted. The mean follow-up was 25 months. To evaluate the effect of several host-, surgery-, and implant-related factors, marginal bone loss (MBL was considered an indicator of success rate (SCR. The Kaplan Meier algorithm and Cox regression were used. RESULTS: Only 5 out of 94 implants were lost (i.e. survival rate - SVR 95.7% and no differences were detected among the studied variables. On the contrary, the Cox regression showed that the graft site (i.e. maxilla reduced MBL. CONCLUSIONS: NDI inserted in FFB have a high SVR and SCR similar to those reported in previous studies on regular and NDI inserted in non-grafted jaws. Homologue FFB is a valuable material in the insertion of NDI.

  9. Insertion compounds of transition-metal and uranium oxides

    International Nuclear Information System (INIS)

    Chippindale, A.M.; Dickens, P.G.; Powell, A.V.

    1991-01-01

    Several transition-metal and actinide oxides, in which the metal occurs in a high oxidation state, have open covalent structures and are capable of incorporating alkali and other electropositive metals under mild conditions to form insertion compounds A x MO n . These are solids which have several features in common: Over a range of compositions, A x MO n exists as one or more stable or metastable phases in which the structure of the parent oxide MO n is largely retained and the insertion element A is accommodated interstitially. Insertion is accompanied by a redox process A=A i . + e - M in which M is reduced and the electronic properties of the parent oxide change to those typical of a mixed-valence compound. The insertion process xA + MO n = A x MO n can be reversed, at least to some extent, by chemical or electrochemical reaction, with retention of structure (topotactic reaction). This review concentrates on methods of synthesis, characterisation, crystal structure and thermochemistry of these insertion compounds. It updates and extends previous work. (author)

  10. Seamless lesion insertion in digital mammography: methodology and reader study

    Science.gov (United States)

    Pezeshk, Aria; Petrick, Nicholas; Sahiner, Berkman

    2016-03-01

    Collection of large repositories of clinical images containing verified cancer locations is costly and time consuming due to difficulties associated with both the accumulation of data and establishment of the ground truth. This problem poses a significant challenge to the development of machine learning algorithms that require large amounts of data to properly train and avoid overfitting. In this paper we expand the methods in our previous publications by making several modifications that significantly increase the speed of our insertion algorithms, thereby allowing them to be used for inserting lesions that are much larger in size. These algorithms have been incorporated into an image composition tool that we have made publicly available. This tool allows users to modify or supplement existing datasets by seamlessly inserting a real breast mass or micro-calcification cluster extracted from a source digital mammogram into a different location on another mammogram. We demonstrate examples of the performance of this tool on clinical cases taken from the University of South Florida Digital Database for Screening Mammography (DDSM). Finally, we report the results of a reader study evaluating the realism of inserted lesions compared to clinical lesions. Analysis of the radiologist scores in the study using receiver operating characteristic (ROC) methodology indicates that inserted lesions cannot be reliably distinguished from clinical lesions.

  11. The wear rates and performance of three mold insert materials

    International Nuclear Information System (INIS)

    Zhong, Z.W.; Leong, M.H.; Liu, X.D.

    2011-01-01

    In this study, a rapidly solidified aluminum alloy was compared with beryllium copper and 6061 aluminum alloys in terms of their wear rates, hardness and performance as mold insert materials. A Vickers hardness measuring machine and a tribometer were used to determine the hardness values and wear rates of the materials. Three sets of mold inserts were made of these materials, and the insert surfaces and the molded plastic lens surfaces were characterized using a scanning electron microscope and a surface profilometer, respectively. The investigation results indicate that the BeCu alloy has the lowest wear rate, while aluminum 6061-T6 has the highest wear rate. Although the rapidly solidified aluminum alloy is not as hard as the BeCu alloy, the differences between their wear rates and hardness values are not as great as the differences between aluminum 6061-T6 and the BeCu alloy. The results also indicate that the rapidly solidified aluminum alloy performs much better than aluminum 6061-T6 in molding of plastic lenses and is comparable to the BeCu alloy. It is able to attain finer surfaces of the molded plastic lenses. This is an important finding, and this means that the rapidly solidified aluminum alloy can replace the BeCu alloy as a good mold insert material, because beryllium (Be) is a toxic element. The finding gives the industry a better choice for selection of mold insert materials.

  12. Variation in the insertion of the palmaris longus tendon

    Science.gov (United States)

    Sunil, Vinutha; Rajanna, Shubha; Gitanjali; Kadaba, Jayanthi

    2015-01-01

    The palmaris longus is harvested as a tendon graft in various surgical procedures. We herein report the variations in the insertion of the palmaris longus tendon. During a routine dissection, a rare variation in the insertion of the palmaris longus tendon was observed. In the left forearm, the palmaris longus tendon bifurcated, while in the right forearm, the palmaris longus tendon trifurcated, giving rise to an accessory muscle, which passed superficial to the ulnar artery and ulnar nerve. The accessory muscle was supplied by a deep branch of the ulnar nerve, and the ulnar artery was observed to be tortuous. During reconstructive surgeries, surgeons should bear in mind the accessory muscle. Also, since the palmaris longus muscle provides a very useful graft in tendon surgery, every surgeon should be aware of the variations in the insertion of the palmaris longus tendon. PMID:25640108

  13. The strategic use of inserts in the Brazilian presidential elections

    Directory of Open Access Journals (Sweden)

    Felipe Borba

    2012-01-01

    Full Text Available The aim of this article is to analyze the communication strategies of presidential candidates during the elections held in 2006 and 2010. The focus is on the strategic component of electoral inserts and the methodology consists of investigating how candidates choose to distribute these inserts in the programming of television networks. The results indicate that the candidates pursue different strategies influenced basically by three variables: electoral legislation, their standing in polls and the difference of resources available. In parallel, the article debates the role of the regulation of electoral advertising and how this set of rules influences the level of information of campaigns, the occurrence of attacks, and party strategies. Overall, 2,993 electoral inserts were examined.

  14. Indentation and needle insertion properties of the human eye.

    Science.gov (United States)

    Matthews, A; Hutnik, C; Hill, K; Newson, T; Chan, T; Campbell, G

    2014-07-01

    Characterization of the biomechanical properties of the human eye has a number of potential utilities. One novel purpose is to provide the basis for development of suitable tissue-mimicking material. The purpose of this study was to determine the indentation and needle insertion characteristics on human eye globes and tissue strips. An indenter assessed the elastic response of human eye globes and tissue strips under increasing compressive loads. Needle insertion determined the force (N) needed to penetrate various areas of the eye wall. The results demonstrated that globes underwent slightly greater indentation at the midline than at the central cornea, and corneal strips indented twofold more than scleral strips, although neither difference was significant (P=0.400 and P=0.100, respectively). Significant differences were observed among various areas of needle insertion (Phuman eye construct with potential utility as a model for use in ophthalmology research and surgical teaching.

  15. A nasogastric tube inserted into the gastrocutaneous fistula.

    Science.gov (United States)

    Kim, Yang Soo; Kim, Joon Sung; Yu, In Hee; Jeong, Ji Young; Jung, Sung Hee; Jo, Yil Ryun; Chung, Myung Eun

    2011-12-01

    We reported a case in which a nasogastric tube was inserted into the gastrocutaneous fistula, diagnosed by abdominal computed tomography. A 78-year-old man with a history of recurrent cerebral hemorrhage had a percutaneous endoscopic gastrostomy tube due to dysphagia for 2 years. However, soft tissue infection at the gastrostomy site caused the removal of the tube. Immediately, antibiotic agents were infused. For appropriate hydration and medication, a nasogastric tube was inserted. However, there was no significant improvement of the soft tissue infection. Moreover, the amount of bloody exudate increased. Abdominal computed tomography revealed the nasogastric tube placed under the patient's skin via gastrocutaneous fistula. The nasogastric tube was removed, and an antibiotic agents were maintained. After 3 weeks, the signs of infection fully improved, and percutaneous endoscopic gastrostomy was performed again. This case shows necessities of an appropriate interval between removal of the gastrostomy tube and insertion of a nasogastric tube, and suspicion of existence of gastrocutaneous fistula.

  16. Polyglutamine expansion in huntingtin increases its insertion into lipid bilayers.

    Science.gov (United States)

    Kegel, Kimberly B; Schewkunow, Vitali; Sapp, Ellen; Masso, Nicholas; Wanker, Erich E; DiFiglia, Marian; Goldmann, Wolfgang H

    2009-09-25

    An expanded polyglutamine (Q) tract (>37Q) in huntingtin (htt) causes Huntington disease. Htt associates with membranes and polyglutamine expansion in htt may alter membrane function in Huntington disease through a mechanism that is not known. Here we used differential scanning calorimetry to examine the effects of polyQ expansion in htt on its insertion into lipid bilayers. We prepared synthetic lipid vesicles composed of phosphatidylcholine and phosphatidylethanolamine and tested interactions of htt amino acids 1-89 with 20Q, 32Q or 53Q with the vesicles. GST-htt1-89 with 53Q inserted into synthetic lipid vesicles significantly more than GST-htt1-89 with 20Q or 32Q. We speculate that by inserting more into cell membranes, mutant huntingtin could increase disorder within the lipid bilayer and thereby disturb cellular membrane function.

  17. Synchronized monochromator and insertion device energy scans at SLS

    Science.gov (United States)

    Krempaský, J.; Flechsig, U.; Korhonen, T.; Zimoch, D.; Quitmann, Ch.; Nolting, F.

    2010-06-01

    Synchronous monochromator and insertion device energy scans were implemented at the Surfaces/Interfaces:Microscopy (SIM) beamline in order to provide the users fast X-ray magnetic dichroism studies (XMCD). A simple software control scheme is proposed based on a fast monochromator run-time energy readback which quickly updates the insertion device requested energy during an on-the-fly X-ray absorption scan (XAS). In this scheme the Plain Grating Monochromator (PGM) motion control, being much slower compared with the insertion device (APPLE-II type undulator), acts as a "master" controlling the undulator "slave" energy position. This master-slave software implementation exploits EPICS distributed device control over computer network and allows for a quasi-synchronous motion control combined with data acquisition needed for the XAS or XMCD experiment.

  18. Master-slave robotic system for needle indentation and insertion.

    Science.gov (United States)

    Shin, Jaehyun; Zhong, Yongmin; Gu, Chengfan

    2017-12-01

    Bilateral control of a master-slave robotic system is a challenging issue in robotic-assisted minimally invasive surgery. It requires the knowledge on contact interaction between a surgical (slave) robot and soft tissues. This paper presents a master-slave robotic system for needle indentation and insertion. This master-slave robotic system is able to characterize the contact interaction between the robotic needle and soft tissues. A bilateral controller is implemented using a linear motor for robotic needle indentation and insertion. A new nonlinear state observer is developed to online monitor the contact interaction with soft tissues. Experimental results demonstrate the efficacy of the proposed master-slave robotic system for robotic needle indentation and needle insertion.

  19. Bedside prediction of right subclavian venous catheter insertion length

    Directory of Open Access Journals (Sweden)

    Yoon Ji Choi

    2014-12-01

    Full Text Available Background and objective: The present study aimed to evaluate whether right subclavian vein (SCV catheter insertion depth can be predicted reliably by the distances from the SCV insertion site to the ipsilateral clavicular notch directly (denoted as I-IC, via the top of the SCV arch, or via the clavicle (denoted as I-T-IC and I-C-IC, respectively. Method: In total, 70 SCV catheterizations were studied. The I-IC, I-T-IC, and I-C-IC distances in each case were measured after ultrasound-guided SCV catheter insertion. The actual length of the catheter between the insertion site and the ipsilateral clavicular notch, denoted as L, was calculated by using chest X-ray. Results: L differed from the I-T-IC, I-C-IC, and I-IC distances by 0.14±0.53, 2.19±1.17, and -0.45 ±0.68 cm, respectively. The mean I-T-IC distance was the most similar to the mean L (intraclass correlation coefficient = 0.89. The mean I-IC was significantly shorter than L, while the mean I-C-IC was significantly longer. Linear regression analysis provided the following formula: Predicted SCV catheter insertion length (cm = -0.037 + 0.036 × Height (cm + 0.903 × I-T-IC (cm (adjusted r2 =0.64. Conclusion: The I-T-IC distance may be a reliable bedside predictor of the optimal insertion length for a right SCV cannulation.

  20. Effect of Light Conducting Cylindrical Inserts on Gingival Microleakage

    Directory of Open Access Journals (Sweden)

    SM. Moazzami

    2007-03-01

    Full Text Available Objective: Microleakage in the gingival floor of class II composite restorations can compromise the marginal adaptation of the filling material to the cavity edges. The aim of this study was to evaluate the effect of light conducting cylindrical inserts in decreasing the microleakage of the gingival floor in cavities 1mm below the CEJ.Materials and Methods: Eighty maxillary first molars were randomly divided into eight groups according to use of glass inserts, type of resin (Coltene unfilled resin versus Scotchbond multi purpose and filling technique (one-unit versus incremental. Proximal class II cavities were prepared in all samples with the gingival floor one millimeter below the CEJ. Etched and silan-treated glass inserts were made from 2mm cylindrical bioglass material and cavities were restored according to research protocol. The samples were subjected to 2500 thermal cycles (5-55oC, immersed in 0.5% basic fuchsin solution, embedded in epoxy resin and cut centrally and laterally (buccally or lingually in a mesiodistal direction. Microleakage was scored and collected data were statistically analyzed using Kruskal-Wallis and Mann-Whitney tests.Results: Minimal dye penetration was observed in the group that employed the incre-mental technique along with Scotchbond, with or without glass inserts. A significant difference was observed between the eight groups. In addition the use of the incremental technique and glass inserts had a significant effect on the microleakage of lateral and central sections, respectively. Application of dentin bonding agent signifi-cantly affected both sections.Conclusion: Glass inserts were effective in decreasing cervical microleakage of class II cavities restored with composite resin.

  1. Can femoral dialysis catheter insertion cause a life threatening complication?

    Directory of Open Access Journals (Sweden)

    Nurkay Katrancıoğlu

    2014-09-01

    Full Text Available Venous catheter (VC insertion may be necessary for the patients with renal failure facing vascular access problem. Femoral VCs are commonly used for their lower complication rates especially in emergency clinics. The incidence of bleeding associated with VC is reported 0.5-1.6%, however, life threatening hemorrhage and complications requiring surgical intervention are very rare. In this manuscript, we aimed to present a case with hemolytic uremic syndrome complicated with retroperitoneal hematoma after femoral VC insertion. J Clin Exp Invest 2014; 5 (3: 472-474

  2. Tension Pneumothorax and Subcutaneous Emphysema Complicating Insertion of Nasogastric Tube

    Directory of Open Access Journals (Sweden)

    Narjis AL Saif

    2015-01-01

    Full Text Available Nasogastric tube has a key role in the management of substantial number of hospitalized patients particularly the critically ill. In spite of the apparent simple insertion technique, nasogastric tube placement has its serious perhaps fatal complications which need to be carefully assessed. Pulmonary misplacement and associated complications are commonplace during nasogastric tube procedure. We present a case of tension pneumothorax and massive surgical emphysema in critically ill ventilated patient due to inadvertent nasogastric tube insertion and also discussed the risk factors, complication list, and arrays of techniques for safer tube placement.

  3. Tension Pneumothorax and Subcutaneous Emphysema Complicating Insertion of Nasogastric Tube.

    Science.gov (United States)

    Al Saif, Narjis; Hammodi, Adel; Al-Azem, M Ali; Al-Hubail, Rasheed

    2015-01-01

    Nasogastric tube has a key role in the management of substantial number of hospitalized patients particularly the critically ill. In spite of the apparent simple insertion technique, nasogastric tube placement has its serious perhaps fatal complications which need to be carefully assessed. Pulmonary misplacement and associated complications are commonplace during nasogastric tube procedure. We present a case of tension pneumothorax and massive surgical emphysema in critically ill ventilated patient due to inadvertent nasogastric tube insertion and also discussed the risk factors, complication list, and arrays of techniques for safer tube placement.

  4. Metallocene Catalytic Insertion Polymerization of 1-Silene to Polycarbosilanes

    Science.gov (United States)

    Tian, Yuelong; Ge, Min; Zhang, Weigang; Lv, Xiaoxu; Yu, Shouquan

    2015-11-01

    Metallocene of zirconium were used as a catalyst for an insertion polymerization of 1-methylsilene directly into pre-ceramic precursor polyzirconocenecarbosilane (PZCS) during dechlorination of dichlorodimethylesilane by sodium, which exhibits high catalytic effectiveness with the maximum conversion ratio of polycarbosilane up to 91%. The average molecular weights of polymers synthesized are less than 1400, all with very narrow polymolecularities. The mechanism of catalytic polymerization was assumed to be similar to a coordination insertion polymerization of 1-olefins by metallocenes. The obtained PZCS show high ceramic yields with formation of composite ceramics of ZrC-SiC, which are novel polymeric precursors of ultra-high temperature ceramic (UHTC) fiber and composite.

  5. Using PATIMDB to create bacterial transposon insertion mutant libraries.

    Science.gov (United States)

    Urbach, Jonathan M; Wei, Tao; Liberati, Nicole; Grenfell-Lee, Daniel; Villanueva, Jacinto; Wu, Gang; Ausubel, Frederick M

    2009-04-01

    PATIMDB is a software package for facilitating the generation of transposon mutant insertion libraries. The software has two main functions: process tracking and automated sequence analysis. The process tracking function specifically includes recording the status and fates of multiwell plates and samples in various stages of library construction. Automated sequence analysis refers specifically to the pipeline of sequence analysis starting with ABI files from a sequencing facility and ending with insertion location identifications. The protocols in this unit describe installation and use of PATIMDB software.

  6. Fabrication of Functional Plastic Parts Using Nanostructured Steel Mold Inserts

    Directory of Open Access Journals (Sweden)

    Nicolas Blondiaux

    2017-06-01

    Full Text Available We report on the fabrication of sub-micro and nanostructured steel mold inserts for the replication of nanostructured immunoassay biochips. Planar and microstructured stainless steel inserts were textured at the sub-micron and nanoscale by combining nanosphere lithography and electrochemical etching. This allowed the fabrication of structures with lateral dimensions of hundreds of nanometers and aspect ratios of up to 1:2. Nanostructured plastic parts were produced by means of hot embossing and injection molding. Surface nanostructuring was used to control wettability and increase the sensitivity of an immunoassay.

  7. Imaging of the complications of peripherally inserted central venous catheters

    International Nuclear Information System (INIS)

    Amerasekera, S.S.H.; Jones, C.M.; Patel, R.; Cleasby, M.J.

    2009-01-01

    Peripherally inserted central catheters (PICC) are widely used to provide central venous access, often in chronically ill patients with long-term intravenous access requirements. There are a number of significant complications related to both insertion and maintenance of PICC lines, including catheter malposition, migration, venous thrombosis, and line fracture. The incidence of these complications is likely to rise as the number of patients undergoing intravenous outpatient therapy increases, with a corresponding rise in radiologist input. This paper provides an overview of the relevant peripheral and central venous anatomy, including anatomical variations, and outlines the complications of PICC lines. Imaging examples demonstrate the range of radiological findings seen in these complications.

  8. Imaging of the complications of peripherally inserted central venous catheters

    Energy Technology Data Exchange (ETDEWEB)

    Amerasekera, S.S.H. [Department of Radiology, Good Hope Hospital, Sutton Coldfield, Birmingham (United Kingdom)], E-mail: steve.amerasekera@nhs.net; Jones, C.M.; Patel, R.; Cleasby, M.J. [Department of Radiology, Good Hope Hospital, Sutton Coldfield, Birmingham (United Kingdom)

    2009-08-15

    Peripherally inserted central catheters (PICC) are widely used to provide central venous access, often in chronically ill patients with long-term intravenous access requirements. There are a number of significant complications related to both insertion and maintenance of PICC lines, including catheter malposition, migration, venous thrombosis, and line fracture. The incidence of these complications is likely to rise as the number of patients undergoing intravenous outpatient therapy increases, with a corresponding rise in radiologist input. This paper provides an overview of the relevant peripheral and central venous anatomy, including anatomical variations, and outlines the complications of PICC lines. Imaging examples demonstrate the range of radiological findings seen in these complications.

  9. Definition of Metrics to Evaluate Cochlear Array Insertion Forces Performed with Forceps, Insertion Tool, or Motorized Tool in Temporal Bone Specimens

    Directory of Open Access Journals (Sweden)

    Yann Nguyen

    2014-01-01

    Full Text Available Introduction. In order to achieve a minimal trauma to the inner ear structures during array insertion, it would be suitable to control insertion forces. The aim of this work was to compare the insertion forces of an array insertion into anatomical specimens with three different insertion techniques: with forceps, with a commercial tool, and with a motorized tool. Materials and Methods. Temporal bones have been mounted on a 6-axis force sensor to record insertion forces. Each temporal bone has been inserted, with a lateral wall electrode array, in random order, with each of the 3 techniques. Results. Forceps manual and commercial tool insertions generated multiple jerks during whole length insertion related to fits and starts. On the contrary, insertion force with the motorized tool only rose at the end of the insertion. Overall force momentum was 1.16 ± 0.505 N (mean ± SD, n=10, 1.337 ± 0.408 N (n=8, and 1.573 ± 0.764 N (n=8 for manual insertion with forceps and commercial and motorized tools, respectively. Conclusion. Considering force momentum, no difference between the three techniques was observed. Nevertheless, a more predictable force profile could be observed with the motorized tool with a smoother rise of insertion forces.

  10. Insertion of internal alkynes and ethene into permethylated single tucked-in titanocene

    Czech Academy of Sciences Publication Activity Database

    Pinkas, Jiří; Císařová, I.; Gyepes, R.; Horáček, Michal; Kubišta, Jiří; Čejka, Jiří; Gómez-Ruiz, S.; Hey-Hawkins, E.; Mach, Karel

    2008-01-01

    Roč. 27, č. 21 (2008), s. 5532-5547 ISSN 0276-7333 R&D Projects: GA AV ČR IAA400400708; GA MŠk(CZ) LC06070 Institutional research plan: CEZ:AV0Z40400503 Keywords : alkynes * titanocene * ethene Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 3.815, year: 2008

  11. Simplified bone-anchored hearing aid insertion using a linear incision without soft tissue reduction.

    Science.gov (United States)

    Husseman, J; Szudek, J; Monksfield, P; Power, D; O'Leary, S; Briggs, R

    2013-07-01

    Numerous techniques have been described to manage the skin and other soft tissues during bone-anchored hearing aid insertion. Previously, generally accepted techniques have sometimes led to distressing alopecia and soft tissue defects. Now, some surgeons are rejecting the originally described split skin flap in favour of a less invasive approach. To investigate bone-anchored hearing aid placement utilising a single, linear incision with either no or minimal underlying soft tissue reduction. Thirty-four adults were prospectively enrolled to undergo single-stage bone-anchored hearing aid placement with this modified technique. A small, linear incision was used at the standard position and carried down through the periosteum. Standard technique was then followed with placement of an extended length abutment. Patients were reviewed regularly to assess wound healing, including evaluation with Holgers' scale. Only 14.7 per cent of patients had a reaction score of 2 or higher. Most complications were limited to minor skin reactions that settled with silver nitrate cautery and/or antibiotics. None required revision surgery for tissue overgrowth, and there were no implant failures. Our results suggest this to be a simple and effective insertion technique with favourable cosmesis and patient satisfaction.

  12. [Comparison of sevoflurane concentration for insertion of proseal laryngeal mask airway and tracheal intubation in children (correlation with BIS)].

    Science.gov (United States)

    Mudakanagoudar, Mahantesh S; Santhosh, M C B

    2016-01-01

    Sevoflurane is an inhalational agent of choice in paediatric anaesthesia. For management of airways in children a suitable alternative to ETT is a paediatric proseal laryngeal mask airway (benchmark second generation SAD). Various studies have shown that less sevoflurane concentration is required for LMA insertion in comparison to TI. BIS is a useful monitor of depth of anaesthesia. To compare concentration of sevoflurane (end tidal and MAC value) required for proseal laryngeal mask airway insertion and tracheal intubation in correlation with BIS index. The prospective randomised single blind study was done in children between 2 and 9 years of ASA I and II and they were randomly allocated to Group P (proseal laryngeal mask airway insertion) and Group TI (tracheal intubation). No sedative premedication was given. Induction was done with 8% sevoflurane and then predetermined concentration was maintained for 10min. Airway was secured either by proseal laryngeal mask airway or endotracheal tube without using muscle relaxant. End tidal sevoflurane concentration, MAC, BIS, and other vital parameters were monitored every minute till insertion of an airway device. Insertion conditions were observed. Statistical analysis was done by Anova and Student's t test. Difference between ETLMI (2.49±0.44) and ETTI (2.81±0.65) as well as MACLMI (1.67±0.13) and MACTI (1.77±0.43) was statistically very significant, while BISLMI (49.05±10.76) and BISTI (41.25±3.25) was significant. Insertion conditions were comparable in both the groups. We can conclude that in children airway can be secured safely with proseal laryngeal mask airway using less sevoflurane concentration in comparison to tracheal intubation and this was supported by BIS index. Copyright © 2014. Publicado por Elsevier Editora Ltda.

  13. Comparison of sevoflurane concentration for insertion of proseal laryngeal mask airway and tracheal intubation in children (correlation with BIS

    Directory of Open Access Journals (Sweden)

    Mahantesh S. Mudakanagoudar

    2016-02-01

    Full Text Available BACKGROUND: Sevoflurane is an inhalational agent of choice in paediatric anaesthesia. For management of airways in children a suitable alternative to ETT is a paediatric proseal laryngeal mask airway (benchmark second generation SAD. Various studies have shown that less sevoflurane concentration is required for LMA insertion in comparison to TI. BIS is a useful monitor of depth of anaesthesia. AIMS: To compare concentration of sevoflurane (end tidal and MAC value required for proseal laryngeal mask airway insertion and tracheal intubation in correlation with BIS index. METHOD: The prospective randomised single blind study was done in children between 2 and 9 years of ASA I and II and they were randomly allocated to Group P (proseal laryngeal mask airway insertion and Group TI (tracheal intubation. No sedative premedication was given. Induction was done with 8% sevoflurane and then predetermined concentration was maintained for 10 min. Airway was secured either by proseal laryngeal mask airway or endotracheal tube without using muscle relaxant. End tidal sevoflurane concentration, MAC, BIS, and other vital parameters were monitored every minute till insertion of an airway device. Insertion conditions were observed. Statistical analysis was done by ANOVA and Students t test. RESULTS: Difference between ETLMI (2.49 ± 0.44 and ETTI (2.81 ± 0.65 as well as MACLMI (1.67 ± 0.13 and MACTI (1.77 ± 0.43 was statistically very significant, while BISLMI (49.05 ± 10.76 and BISTI (41.25 ± 3.25 was significant. Insertion conditions were comparable in both the groups. CONCLUSION: We can conclude that in children airway can be secured safely with proseal laryngeal mask airway using less sevoflurane concentration in comparison to tracheal intubation and this was supported by BIS index.

  14. Comparison of sevoflurane concentration for insertion of proseal laryngeal mask airway and tracheal intubation in children (correlation with BIS).

    Science.gov (United States)

    Mudakanagoudar, Mahantesh S; Santhosh, M C B

    2016-01-01

    Sevoflurane is an inhalational agent of choice in paediatric anaesthesia. For management of airways in children a suitable alternative to ETT is a paediatric proseal laryngeal mask airway (benchmark second generation SAD). Various studies have shown that less sevoflurane concentration is required for LMA insertion in comparison to TI. BIS is a useful monitor of depth of anaesthesia. To compare concentration of sevoflurane (end tidal and MAC value) required for proseal laryngeal mask airway insertion and tracheal intubation in correlation with BIS index. The prospective randomised single blind study was done in children between 2 and 9 years of ASA I and II and they were randomly allocated to Group P (proseal laryngeal mask airway insertion) and Group TI (tracheal intubation). No sedative premedication was given. Induction was done with 8% sevoflurane and then predetermined concentration was maintained for 10 min. Airway was secured either by proseal laryngeal mask airway or endotracheal tube without using muscle relaxant. End tidal sevoflurane concentration, MAC, BIS, and other vital parameters were monitored every minute till insertion of an airway device. Insertion conditions were observed. Statistical analysis was done by ANOVA and Students t test. Difference between ETLMI (2.49 ± 0.44) and ETTI (2.81 ± 0.65) as well as MACLMI (1.67 ± 0.13) and MACTI (1.77 ± 0.43) was statistically very significant, while BISLMI (49.05 ± 10.76) and BISTI (41.25 ± 3.25) was significant. Insertion conditions were comparable in both the groups. We can conclude that in children airway can be secured safely with proseal laryngeal mask airway using less sevoflurane concentration in comparison to tracheal intubation and this was supported by BIS index. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  15. Codon cassette mutagenesis: a general method to insert or replace individual codons by using universal mutagenic cassettes.

    OpenAIRE

    Kegler-Ebo, D M; Docktor, C M; DiMaio, D

    1994-01-01

    We describe codon cassette mutagenesis, a simple method of mutagenesis that uses universal mutagenic cassettes to deposit single codons at specific sites in double-stranded DNA. A target molecule is first constructed that contains a blunt, double-strand break at the site targeted for mutagenesis. A double-stranded mutagenic codon cassette is then inserted at the target site. Each mutagenic codon cassette contains a three base pair direct terminal repeat and two head-to-head recognition sequen...

  16. The supermodule insertion tool of the CMS electromagnetic calorimeter and the first trial insertion of a supermodule.

    CERN Multimedia

    Maximilien Brice

    2006-01-01

    The first trial insertion of a complete Electromagnetic Calorimeter (ECAL) "supermodule" (1700 lead-tungstate crystals, with support structures, light detectors (avalanche photodiodes), readout electronics and cooling system) was performed on 1st March. This delicate operation - sliding a 2-tonne 3m-long object onto support rails (in real life these are attached to the barrel hadron calorimeter (HCAL)) - made use of a custom designed "squirrel cage". The rotatable squirrel cage allows the insertion of any supermodule into any of the 18 positions, including very fine (sub-mm) adjustments. The first supermodule will be inserted into the real HCAL later this month in preparation for the "magnet test and cosmic-ray challenge" (MTCC). In the first image the supermodule is in the centre and the alignment disks are highlighted by the flash.

  17. Initial clinical experience with a misoprostol vaginal insert in comparison with a dinoprostone insert for inducing labor.

    Science.gov (United States)

    Mayer, Richard Bernhard; Oppelt, Peter; Shebl, Omar; Pömer, Joachim; Allerstorfer, Christina; Weiss, Christoph

    2016-05-01

    Only one phase III trial has been published to date on the efficacy and safety of misoprostol vaginal inserts for inducing labor. The aim of this study was to compare misoprostol inserts with dinoprostone inserts. This retrospective cohort study evaluated the reduction in time to vaginal delivery and delivery within 24h, in routine clinical work, in 119 labor inductions using a 200-μg misoprostol vaginal insert (Misodel(®); June-October 2014) in comparison with 124 inductions using a 10-mg dinoprostone insert (Propess(®); December 2013-April 2014). Vaginal delivery within 24h occurred in 77.3% (n=92) of the misoprostol cohort and 74.2% (n=92) of the dinoprostone cohort (P=0.654). Time from insert application to vaginal delivery (min) was 761.76 (±409.44, cohort M) versus 805.17 (±473.00, cohort D) (P=0.817). Cesarean delivery was performed in 10.1% (n=12) versus 10.5% (n=13) in the misoprostol and dinoprostone cohorts, respectively (P≥0.999). The modified Bishop scores were 2.0 versus 3.0 (P=0.001), mean body mass index (BMI) was 24.72 versus 23.95 (P=0.033), and fetal scalp blood testing was required in 12.6% (n=15) versus 3.2% (n=4; P=0.008). No differences were observed with regard to the rates of transfer to the neonatal unit or any type of fetal acidosis. The groups thus had similar results for rates of vaginal delivery within 24h, cesarean delivery and fetal outcomes. The misoprostol group had lower modified Bishop scores, higher BMIs, and a higher rate of fetal scalp blood testing. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. Pneumonia and mortality after percutaneous endoscopic gastrostomy insertion.

    Science.gov (United States)

    Azzopardi, Neville; Ellul, Pierre

    2013-01-01

    Percutaneous endoscopic gastrostomy feeding provides enteral nutrition to patients with neurological dysphagia. Thirty-day mortality rates of 4-26% have been reported, with pneumonia being the common cause post-percutaneous endoscopic gastrostomy insertion. This retrospective analysis of percutaneous endoscopic gastrostomy tube insertions in Malta (January 2008 - June 2010) compares the incidence of pneumonia in patients fed through a nasogastric tube versus in those fed via a percutaneous endoscopic gastrostomy tube. We analyzed the indications, poor prognostic factors and mortality for percutaneous endoscopic gastrostomy insertion. Ninety-seven patients underwent percutaneous endoscopic gastrostomy insertion. Fifty-four patients received nasogastric feeds before percutaneous endoscopic gastrostomy feeds. Patients on nasogastric feeds developed 32 episodes of pneumonia over a total of 7884 days of feeds (1 every 246 days). Patients with percutaneous endoscopic gastrostomy feeds after a period of nasogastric feeds developed 48 pneumonia episodes over 36,238 days (1 every 755 days). Patients with percutaneous endoscopic gastrostomy feeds without previous nasogastric feeds developed 28 pneumonia episodes over 23,983 days (1 every 856 days), and this was statistically significant (χ 2 test p value nasogastric feeds. However, pneumonia is still the major cause of death among percutaneous endoscopic gastrostomy patients.

  19. Retrospective Review of Current Nasojejunal Tube Insertion Practice

    Directory of Open Access Journals (Sweden)

    Natasha Sheikh MSc

    2015-01-01

    Full Text Available Repeated fluoroscopically guided nasojejunal tube (NJT insertions, particularly in children, can pose health risks through increased radiation exposure. We analyzed frequency of NJT reinsertions and associated radiation exposure through retrospective evaluation of children <18 years at our institution who underwent fluoroscopically guided NJT insertions from 2007 to 2012. Age and weight, reinsertion frequency per patient, radiation dose (dose actual percentage [DAP], time interval between, and indication for reinsertion were recorded. A total of 252 children (3 days to17 years, 11 months had 449 NJT insertions. Reinsertions occurred in 105 (41.7% patients with 14 (5.6% having ≥5 reinsertions, and 67.6% of reinsertions occurring in patients <1 year. Mean DAP increased with frequency of reinsertion, along with age and weight. Most common indication for reinsertion was a pulled NJT (34.0%. Fluoroscopic NJT reinsertion was most frequent in younger, smaller patients. Self-guided, bedside NJT insertion, and/or earlier instigation of definitive nutritional therapy delivery should be considered.

  20. Inserting digital watermark by method on delaying echo

    Directory of Open Access Journals (Sweden)

    Vitaliy Grigorievich Ivanenko

    2016-03-01

    Full Text Available The questions of the fight against piracy in media, using digital watermarks have considered. Main requirements have been formulated, which integration method have to satisfy. Method of inserting digital watermark, founded on delay echo. Principal characteristics of applications of chosen method have been listed.

  1. Effects of Rotational Motion in Robotic Needle Insertion

    Science.gov (United States)

    Ramezanpour, H.; Yousefi, H.; Rezaei, M.; Rostami, M.

    2015-01-01

    Background Robotic needle insertion in biological tissues has been known as one the most applicable procedures in sampling, robotic injection and different medical therapies and operations. Objective In this paper, we would like to investigate the effects of angular velocity in soft tissue insertion procedure by considering force-displacement diagram. Non-homogenous camel liver can be exploited as a tissue sample under standard compression test with Zwick/Roell device employing 1-D axial load-cell. Methods Effects of rotational motion were studied by running needle insertion experiments in 5, 50 and 200 mm/min in two types of with or without rotational velocity of 50, 150 and 300 rpm. On further steps with deeper penetrations, friction force of the insertion procedure in needle shaft was acquired by a definite thickness of the tissue. Results Designed mechanism of fixture for providing different frequencies of rotational motion is available in this work. Results for comparison of different force graphs were also provided. Conclusion Derived force-displacement graphs showed a significant difference between two procedures; however, tissue bleeding and disorganized micro-structure would be among unavoidable results. PMID:26688800

  2. Supraventricular tachycardia following insertion of a central venous catheter

    Directory of Open Access Journals (Sweden)

    Yavascan Onder

    2009-01-01

    Full Text Available Placement of central venous catheters (CVCs in patients is associated with several risks including endocardial injury and dysrhythmias. In addition, CVC extending into intracardiac chambers can provoke premature atrial and ventricular complexes, which have been reported to initiate supraventricular tachycardia (SVT. A 15-year-old boy with end-stage renal failure developed SVT after insertion of a CVC.

  3. Effects of lithium insertion on thermal conductivity of silicon nanowires

    International Nuclear Information System (INIS)

    Xu, Wen; Zhang, Gang; Li, Baowen

    2015-01-01

    Recently, silicon nanowires (SiNWs) have been applied as high-performance Li battery anodes, since they can overcome the pulverization and mechanical fracture during lithiation. Although thermal stability is one of the most important parameters that determine safety of Li batteries, thermal conductivity of SiNWs with Li insertion remains unclear. In this letter, using molecular dynamics simulations, we study room temperature thermal conductivity of SiNWs with Li insertion. It is found that compared with the pristine SiNW, there is as much as 60% reduction in thermal conductivity with 10% concentration of inserted Li atoms, while under the same impurity concentration the reduction in thermal conductivity of the mass-disordered SiNW is only 30%. With lattice dynamics calculations and normal mode decomposition, it is revealed that the phonon lifetimes in SiNWs decrease greatly due to strong scattering of phonons by vibrational modes of Li atoms, especially for those high frequency phonons. The observed strong phonon scattering phenomenon in Li-inserted SiNWs is similar to the phonon rattling effect. Our study serves as an exploration of thermal properties of SiNWs as Li battery anodes or weakly coupled with impurity atoms

  4. Angiotensin-converting enzyme insertion/deletion gene ...

    Indian Academy of Sciences (India)

    Angiotensin-converting enzyme insertion/deletion gene polymorphism in cystic fibrosis patients. Sabrine Oueslati Sondess Hadj Fredj Hajer Siala Amina Bibi Hajer Aloulou Lamia Boughamoura Khadija Boussetta Sihem Barsaoui Taieb Messaoud. Research Note Volume 95 Issue 1 March 2016 pp 193-196 ...

  5. Nasogastric tube insertion in anaesthetized patients: a comprehensive review.

    Science.gov (United States)

    Sanaie, Sarvin; Mahmoodpoor, Ata; Najafi, Mahdi

    2017-01-01

    Nasogastric tubes (NGT) still remain the easiest and the best way for gastrointestinal tract access. There are various indications for the insertion of a nasogastric tube in anaesthetized and critically ill patients. Although many techniques have been introduced to facilitate nasogastric tube insertion using anatomic landmarks and a group of devices, there is no consensus on a standard method. Moreover, there are different methods for the assessment of the correct placement of a nasogastric tube. In addition to these challenges in insertion and assessment methods, there are varieties of major life-threatening and minor complications to be addressed. Thus, selecting the most appropriate approach requires enough knowledge in this area, considering patient condition and clinical factors, as well as the practitioners' sufficient education and experience, along with skill in performance. This is a comprehensive review of the literature evidence on different methods for nasogastric tube insertion, on the assessment of correct placement and the evaluation of complications, in addition to an approach to the effect of education on the quality of routine practice and patients' outcome.  .

  6. Surgical insertion of transmitters and telemetry methods in fisheries research

    DEFF Research Database (Denmark)

    Rub, A. Michelle Wargo; Jepsen, Niels; Liedtke, Theresa L.

    2014-01-01

    ) will be described. Effects of surgical insertion of transmitters (ie, tagging) and aspects of the surgical implantation process where collaboration and professional exchanges among nonveterinarian researchers and veterinarians may be most fruitful will be discussed. Although this report focuses on surgical...

  7. Cardiac tamponade due to peripheral inserted central catheter in newborn

    Directory of Open Access Journals (Sweden)

    Maria Fernanda Pellegrino da Silva Dornaus

    2011-09-01

    Full Text Available ABSTRACT This article reports the case of an adverse event of cardiac tamponade associated with central catheter peripheral insertion in a premature newborn. The approach was pericardial puncture, which reversed the cardiorespiratory arrest. The newborn showed good clinical progress and was discharged from hospital with no complications associated with the event.

  8. SPS, quadrupole and vacuum chamber for low-beta insertion

    CERN Multimedia

    CERN PhotoLab

    1981-01-01

    During operation of the SPS as a proton-antiproton collider, 2 low-beta insertions (in LSS4 and LSS5) reduced the beam sizes and thereby increased the luminosity. The quadrupoles close to the intersection points had special, "flower-shaped", vacuum chambers. A detailed description is given in CERN Annual Report 1981, p.121.

  9. Prophylactic Antibiotics Use at IUCD Insertion and Pelvic Infection in ...

    African Journals Online (AJOL)

    Only one had positive preinsertion swab for Chlamydia, and only one client had clinical pelvic inflammatory disease (PID) with negative swab. Conclusion: Pelvic infection with Chlamydia isolation was not common amongst new IUCD insertions to warrant routine antibiotic prophylaxis in Brook Jersey. All cases of pelvic ...

  10. Comparative Analysis of Patient Package Inserts of Local and ...

    African Journals Online (AJOL)

    Background and Objective: The patient package insert is an important source of drug information. The aim of this study was to evaluate and compare the PPI of the anti-infective agents manufactured in Palestine with the imported equivalents. Method: The selection criteria generated 15 different antiinfective agents available ...

  11. The insertion/deletion polymorphism of angiotensin-converting ...

    African Journals Online (AJOL)

    The association between type 2 diabetes mellitus (T2DM) and essential hypertension (EH) is not well understood. Both conditions result from an interaction of multiple genetic (ethnic) and environmental (geographical) factors. One possible genetic determinant is the angiotensin-converting enzyme (ACE) insertion/deletion ...

  12. An angiotensin I-converting enzyme insertion/deletion ...

    Indian Academy of Sciences (India)

    Angiotensin I-converting enzyme (ACE) plays a majorrole in fibrous tissue formation and is highly expressed in lungs. The main aim of this research work was to study the roleof ACE insertion/deletion (I/D) polymorphism, rs4646994, in asthma in Pakistani patients. A total of 854 subjects,including 333 asthma patients and ...

  13. NOVEL INSERTION SEQUENCE-LIKE ELEMENT IS982 IN LACTOCOCCI

    NARCIS (Netherlands)

    YU, WZ; MIERAU, [No Value; MARS, A; JOHNSON, E; DUNNY, G; MCKAY, LL

    A novel insertion sequence-like (IS) element, designated IS982, was found on the lactose plasmid, pSK11L, from Lactococcus lactis subsp. cremoris SK11 and was located between the origin of replication and the oligopeptide transport gene cluster. The 1003-base pair (bp) IS982 was flanked by 18-bp

  14. Lack of Association of Insertion/Deletion Polymorphism in ...

    African Journals Online (AJOL)

    DRNAQSHAB

    2012-01-19

    Jan 19, 2012 ... associated with nephropathy in type 2 diabetic patients of Punjabi population of Pakistan. Key words: Angiotensin converting enzymes, insertion/deletion polymorphism, albuminuria and type 2 diabetes mellitus. INTRODUCTION. Diabetic nephropathy is a leading cause of diabetic. *Corresponding author.

  15. Enhancement of heat transfer using varying width twisted tape inserts

    African Journals Online (AJOL)

    user

    Augmentation of convective heat transfer in internal flows with tape inserts in tubes is a well-acclaimed technique employed ...... Her research interests include IC Engines, Combustion modeling, Alternate fuels, Heat transfer, Refrigeration and Air-conditioning. She has published more than 8 papers in International journals.

  16. External Tank (ET) Bipod Fitting Bolted Attachment Locking Insert Performance

    Science.gov (United States)

    Larsen, Curtis E.; Wilson, Tim R.; Elliott, Kenny B.; Raju, Ivatury S.; McManamen, John

    2008-01-01

    Following STS-107, the External Tank (ET) Project implemented corrective actions and configuration changes at the ET bipod fitting. Among the corrective actions, the existing bolt lock wire which provided resistance to potential bolt rotation was removed. The lock wire removal was because of concerns with creating voids during foam application and potential for lock wire to become debris. The bolts had been previously lubricated to facilitate assembly but, because of elimination of the lock wire, the ET Project wanted to enable the locking feature of the insert. Thus, the lubrication was removed from bolt threads and instead applied to the washer under the bolt head. Lubrication is necessary to maximize joint pre-load while remaining within the bolt torque specification. The locking feature is implemented by thread crimping in at four places in the insert. As the bolt is torqued into the insert the bolt threads its way past the crimped parts of the insert. This provides the locking of the bolt, as torque is required to loosen the joint after clamping.

  17. Experience with UIDC insertion outside of menses in Kenya ...

    African Journals Online (AJOL)

    %) or insertion outside of menses (6.9%), than the within menses (4.3%) groups. However, the differences were not statistically significant. Adjusted odds ratios for IUCD outside of menses and oligomenorrhoea/amenorrhea groups were 1.65 ...

  18. 41 CFR 50-201.3 - Insertion of stipulations.

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 1 2010-07-01 2010-07-01 true Insertion of stipulations. 50-201.3 Section 50-201.3 Public Contracts and Property Management Other Provisions Relating to...) The foregoing stipulations shall be deemed inoperative if this contract is for a definite amount not...

  19. Otological Findings Ten Years after Myringotomy with Tympanostomy Tube Insertion

    Directory of Open Access Journals (Sweden)

    Ali Goljanian Tabrizi

    2011-01-01

    Full Text Available Introduction: To study the long-term complications of tympanostomy tube insertion in young children 10 years after surgery.   Materials and Methods: In September 2011, the medical records of all patients who had undergone myringotomy with tympanostomy tube insertion between February 2000 and March 2001 at the two general hospitals of Isfahan University of Medical Sciences were studied. Of the 98 patients who fulfilled the inclusion criteria, 82 patients agreed to participate and were enrolled in the study. The complications of the operation were evaluated in these patients.   Results: Of the 164 ears that were operated on, myringosclerosis was found in 17.1%, atrophy of the tympanic membrane in 1.2%, permanent perforation of the tympanic membrane in 0.6% and tympanic membrane atelectasis in 0.6%. None of the patients developed cholesteatoma as a complication of tympanostomy tube insertion.   Conclusion:  Considering the low risk of serious complications after 10 years, tympanostomy tube insertion is a safe and effective treatment option in the treatment of otitis media with effusion.

  20. Laparoscopically inserted button colostomy as a venting stoma and ...

    African Journals Online (AJOL)

    This is done mainly for relief of gaseous distension and constipation in an attempt to provide symptomatic relief and improve quality of life. In this article, we present our preliminary results of laparoscopically assisted technique to insert a Mic-Key gastrostomy device as a 'button colostomy' in 8 patients over the past 6½ years ...

  1. Complications of peripherally inserted central venous catheters in ...

    African Journals Online (AJOL)

    Background: The objective of this study was to assess the complications of peripherally inserted central venous catheters (PICC) in neonates admitted to neonatal surgical intensive care unit (NSICU). Patients and Methods: Retrospective analysis of 237 neonates admitted to NSICU from January 2010 to December 2011 ...

  2. Can Peripheral Central Venous Lines be inserted safely and ...

    African Journals Online (AJOL)

    This study was performed to determine whether the placement of a more flexible peripherally inserted catheter, the Arrow PICC (Arrow PS-01651), would result in an improved and acceptable success rate. Method: Twenty-three patients in the casualty unit of the Mamelodi Hospital during 1997 and 1998, who required a ...

  3. Electromagnetically tracked placement of a peripherally inserted central catheter

    Science.gov (United States)

    Sacolick, Laura; Patel, Neilesh; Tang, Jonathan; Levy, Elliot; Cleary, Kevin R.

    2004-05-01

    This paper describes a computer program to utilize electromagnetic tracking guidance during insertion of peripherally inserted central catheters. Placement of a Peripherally Inserted Central Catheter (PICC) line is a relatively simple, routine procedure in which a catheter is inserted into the veins of the lower arm and threaded up the arm to the vena cava to sit just above the heart. However, the procedure requires x-ray verification of the catheter position and is usually done under continuous fluoroscopic guidance. The computer program is designed to replace fluoroscopic guidance in this procedure and make PICC line placement a bedside procedure. This would greatly reduce the time and resources dedicated to this procedure. The physician first goes through a quick registration procedure to register the patient space with the computer screen coordinates. Once registration is completed, the program provides a continuous, real-time display of the position of the catheter tip overlaid on an x-ray image of the patient on an adjacent computer screen. Both the position and orientation of the catheter tip is shown. The display is very similar to that shown when using fluoroscopy.

  4. Prototype ISR Superconducting Quadrupole for the low beta insertion.

    CERN Multimedia

    CERN PhotoLab

    1976-01-01

    The four coils are provisionally kept together by aluminium clamps while epoxy-glass bands are wrapped around them to form a number of spacer rings.Stainless steel spacers were then inserted between these rings and the yoke quadrants. The persons are Michel Bouvier(left) and Pierre Pugin. See also7702690X.

  5. Insertion of lithium in Nb2O5

    International Nuclear Information System (INIS)

    Alves, M.C.M.; Bulhoes, L.O.S.; Castro, S.C.

    1990-01-01

    The electrode process during the reduction and oxidation of Nb sub(2) O sub(5) by cyclic voltametry was characterized. The surface analysis by X-ray photo electronic spectroscopy allowed characterize the surface processes, that happening during the insertion reaction. (author)

  6. Enhancement of heat transfer using varying width twisted tape inserts

    African Journals Online (AJOL)

    Enhancement of heat transfer using varying width twisted tape inserts. ... International Journal of Engineering, Science and Technology ... The present work shows the results obtained from experimental investigations of the augmentation of turbulent flow heat transfer in a horizontal tube by means of varying width twisted ...

  7. Safety of Veress needle insertion in laparoscopic bariatric surgery.

    Science.gov (United States)

    Kosuta, Marco; Palmisano, Silvia; Piccinni, Giuseppe; Guerrini, Jacopo; Giuricin, Michela; Nagliati, Carlo; Casagranda, Biagio; de Manzini, Nicolò

    2014-02-01

    Creating the pneumoperitoneum is the first surgical procedure in laparoscopic abdominal surgery. Morbid obesity is a risk factor for iatrogenic injuries because of the considerable thickness of the abdominal wall. The aim of this study was to assess the feasibility and the incidence of complications when using Veress needles (VN) in obese patients undergoing bariatric surgery. Between March 2004 and December 2010, a retrospective analysis was performed on 139 obese patients (mean body mass index=45.94 kg/m). Blind VN insertion followed by optical trocar insertion was the most widely used technique. Of the 139 patients, VN was successfully used in 138 cases (99.28%), and in 1 patient the procedure failed and an open laparoscopy was performed (0.72%). During the study period, there were 63 gastric bypasses, 18 sleeve gastrectomies, 50 gastric bandings, and 8 reoperations. The VN was inserted in the left upper quadrant in 46 cases and in the midline above the umbilicus in 93 cases. A colonic perforation after VN insertion at the left upper quadrant occurred. The overall rate of complications was 0.72%. There were no access-related complications when VN was inserted above the umbilicus; complication rate was 2.17% at upper left quadrant VN placement. No cases of subcutaneous emphysema or extraperitoneal insufflation were observed. In our experience, the success rate was 98.28% and the overall rate of complications was 0.72%. The VN technique can be considered feasible and safe even when used in obese population.

  8. Mismatch analysis of humeral nailing. Antegrade versus retrograde insertion

    International Nuclear Information System (INIS)

    Mahaisavariya, B.; Jiamwatthanachai, P.; Aroonjarattham, P.; Aroonjarattham, K.; Wongcumchang, M.; Sitthiseripratip, K.

    2011-01-01

    Closed humeral nailing is now considered an alternative treatment for humeral-shaft fracture. The nail can be inserted with either the antegrade or retrograde method. We investigated and compared the problem of geometric mismatch of the humeral nail to the humerus between the two methods of insertion. The study was performed using virtual simulation based on computed tomography (CT) data of 76 Thai cadaveric humeri and the commonly used Russell-Taylor humeral nail 8 mm in diameter and 220 mm long. Mismatch of the nail to the intact humerus was analyzed and compared between the antegrade and retrograde nailing approaches. The results showed: the diameter of the medullary canal averaged 7.9-13.8 mm; the minimal reaming diameter to accommodate virtual nail insertion averaged 8.8-14.8 mm for the antegrade and 8.8-29.3 mm for the retrograde approach; the minimal reaming thickness of the inner cortex averaged 0.1-1.5 mm for the antegrade and 0.1-9.9 mm for the retrograde approach; the percentages of cortical bone removed prior to nail insertion were 3.8-107.1% and 3.8-1,287.6% for the antegrade and retrograde approaches, respectively; the eccentricity of the nail-medullary canal center were 0.4-3.4 and 0.4-10.6 mm for the antegrade and retrograde approaches, respectively. Less mismatching occurred with antegrade nailing than with the retrograde approach. Retrograde nailing requires excessive reaming at the distal part of the humerus to accommodate nail insertion. This may create bone weakness and the risk of supracondylar fracture. (author)

  9. An in vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: an axial positioned dynamic compression plate and two abaxial transarticular cortical screws inserted in lag fashion versus three parallel transarticular cortical screws inserted in lag fashion.

    Science.gov (United States)

    Sod, Gary A; Riggs, Laura M; Mitchell, Colin F; Hubert, Jeremy D; Martin, George S

    2010-01-01

    To compare in vitro monotonic biomechanical properties of an axial 3-hole, 4.5 mm narrow dynamic compression plate (DCP) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion (DCP-TLS) with 3 parallel transarticular 5.5 mm cortical screws inserted in lag fashion (3-TLS) for the equine proximal interphalangeal (PIP) joint arthrodesis. Paired in vitro biomechanical testing of 2 methods of stabilizing cadaveric adult equine forelimb PIP joints. Cadaveric adult equine forelimbs (n=15 pairs). For each forelimb pair, 1 PIP joint was stabilized with an axial 3-hole narrow DCP (4.5 mm) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion and 1 with 3 parallel transarticular 5.5 mm cortical screws inserted in lag fashion. Five matching pairs of constructs were tested in single cycle to failure under axial compression, 5 construct pairs were tested for cyclic fatigue under axial compression, and 5 construct pairs were tested in single cycle to failure under torsional loading. Mean values for each fixation method were compared using a paired t-test within each group with statistical significance set at P<.05. Mean yield load, yield stiffness, and failure load under axial compression and torsion, single cycle to failure, of the DCP-TLS fixation were significantly greater than those of the 3-TLS fixation. Mean cycles to failure in axial compression of the DCP-TLS fixation was significantly greater than that of the 3-TLS fixation. The DCP-TLS was superior to the 3-TLS in resisting the static overload forces and in resisting cyclic fatigue. The results of this in vitro study may provide information to aid in the selection of a treatment modality for arthrodesis of the equine PIP joint.

  10. Pen needle design influences ease of insertion, pain, and skin trauma in subjects with type 2 diabetes.

    Science.gov (United States)

    Præstmark, Kezia A; Jensen, Morten L; Madsen, Nils B; Kildegaard, Jonas; Stallknecht, Bente M

    2016-01-01

    Pen needles used for subcutaneous injections have gradually become shorter, thinner and more thin walled, and thereby less robust to patient reuse. Thus, different needle sizes, alternative tip designs and needles resembling reuse were tested to explore how needle design influences ease of insertion, pain and skin trauma. 30 subjects with injection-treated type 2 diabetes and body mass index 25-35 kg/m 2 were included in the single-blinded study. Each subject received abdominal insertions with 18 different types of needles. All needles were tested twice per subject and in random order. Penetration force (PF) through the skin, pain perception on 100 mm visual analog scale, and change in skin blood perfusion (SBP) were quantified after the insertions. Needle diameter was positively related to PF and SBP (ptrend relation. Lack of needle lubrication and small 'needle hooks' increased PF and SBP (pskin and in polyurethane rubber were linearly related, and pain outcome was dependent of SBP increase. The shape and design of a needle and the needle tip affect ease of insertion, pain and skin trauma. Relations are seen across different data acquisition methods and across species, enabling needle performance testing outside of clinical trials. NCT02531776; results.

  11. Codon cassette mutagenesis: a general method to insert or replace individual codons by using universal mutagenic cassettes.

    Science.gov (United States)

    Kegler-Ebo, D M; Docktor, C M; DiMaio, D

    1994-05-11

    We describe codon cassette mutagenesis, a simple method of mutagenesis that uses universal mutagenic cassettes to deposit single codons at specific sites in double-stranded DNA. A target molecule is first constructed that contains a blunt, double-strand break at the site targeted for mutagenesis. A double-stranded mutagenic codon cassette is then inserted at the target site. Each mutagenic codon cassette contains a three base pair direct terminal repeat and two head-to-head recognition sequences for the restriction endonuclease Sapl, an enzyme that cleaves outside of its recognition sequence. The intermediate molecule containing the mutagenic cassette is then digested with Sapl, thereby removing most of the mutagenic cassette, leaving only a three base cohesive overhang that is ligated to generate the final insertion or substitution mutation. A general method for constructing blunt-end target molecules suitable for this approach is also described. Because the mutagenic cassette is excised during this procedure and alters the target only by introducing the desired mutation, the same cassette can be used to introduce a particular codon at all target sites. Each cassette can deposit two different codons, depending on the orientation in which it is inserted into the target molecule. Therefore, a series of eleven cassettes is sufficient to insert all possible amino acids at any constructed target site. Thus codon cassettes are 'off-the-shelf' reagents, and this methodology should be a particularly useful and inexpensive approach for subjecting multiple different positions in a protein sequence to saturation mutagenesis.

  12. Lesion insertion in the projection domain: Methods and initial results

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Baiyu; Leng, Shuai; Yu, Lifeng; Yu, Zhicong; Ma, Chi; McCollough, Cynthia, E-mail: mccollough.cynthia@mayo.edu [Department of Radiology, Mayo Clinic, Rochester, Minnesota 55905 (United States)

    2015-12-15

    Purpose: To perform task-based image quality assessment in CT, it is desirable to have a large number of realistic patient images with known diagnostic truth. One effective way of achieving this objective is to create hybrid images that combine patient images with inserted lesions. Because conventional hybrid images generated in the image domain fails to reflect the impact of scan and reconstruction parameters on lesion appearance, this study explored a projection-domain approach. Methods: Lesions were segmented from patient images and forward projected to acquire lesion projections. The forward-projection geometry was designed according to a commercial CT scanner and accommodated both axial and helical modes with various focal spot movement patterns. The energy employed by the commercial CT scanner for beam hardening correction was measured and used for the forward projection. The lesion projections were inserted into patient projections decoded from commercial CT projection data. The combined projections were formatted to match those of commercial CT raw data, loaded onto a commercial CT scanner, and reconstructed to create the hybrid images. Two validations were performed. First, to validate the accuracy of the forward-projection geometry, images were reconstructed from the forward projections of a virtual ACR phantom and compared to physically acquired ACR phantom images in terms of CT number accuracy and high-contrast resolution. Second, to validate the realism of the lesion in hybrid images, liver lesions were segmented from patient images and inserted back into the same patients, each at a new location specified by a radiologist. The inserted lesions were compared to the original lesions and visually assessed for realism by two experienced radiologists in a blinded fashion. Results: For the validation of the forward-projection geometry, the images reconstructed from the forward projections of the virtual ACR phantom were consistent with the images physically

  13. Lesion insertion in the projection domain: Methods and initial results.

    Science.gov (United States)

    Chen, Baiyu; Leng, Shuai; Yu, Lifeng; Yu, Zhicong; Ma, Chi; McCollough, Cynthia

    2015-12-01

    To perform task-based image quality assessment in CT, it is desirable to have a large number of realistic patient images with known diagnostic truth. One effective way of achieving this objective is to create hybrid images that combine patient images with inserted lesions. Because conventional hybrid images generated in the image domain fails to reflect the impact of scan and reconstruction parameters on lesion appearance, this study explored a projection-domain approach. Lesions were segmented from patient images and forward projected to acquire lesion projections. The forward-projection geometry was designed according to a commercial CT scanner and accommodated both axial and helical modes with various focal spot movement patterns. The energy employed by the commercial CT scanner for beam hardening correction was measured and used for the forward projection. The lesion projections were inserted into patient projections decoded from commercial CT projection data. The combined projections were formatted to match those of commercial CT raw data, loaded onto a commercial CT scanner, and reconstructed to create the hybrid images. Two validations were performed. First, to validate the accuracy of the forward-projection geometry, images were reconstructed from the forward projections of a virtual ACR phantom and compared to physically acquired ACR phantom images in terms of CT number accuracy and high-contrast resolution. Second, to validate the realism of the lesion in hybrid images, liver lesions were segmented from patient images and inserted back into the same patients, each at a new location specified by a radiologist. The inserted lesions were compared to the original lesions and visually assessed for realism by two experienced radiologists in a blinded fashion. For the validation of the forward-projection geometry, the images reconstructed from the forward projections of the virtual ACR phantom were consistent with the images physically acquired for the ACR

  14. Lesion insertion in the projection domain: Methods and initial results

    International Nuclear Information System (INIS)

    Chen, Baiyu; Leng, Shuai; Yu, Lifeng; Yu, Zhicong; Ma, Chi; McCollough, Cynthia

    2015-01-01

    Purpose: To perform task-based image quality assessment in CT, it is desirable to have a large number of realistic patient images with known diagnostic truth. One effective way of achieving this objective is to create hybrid images that combine patient images with inserted lesions. Because conventional hybrid images generated in the image domain fails to reflect the impact of scan and reconstruction parameters on lesion appearance, this study explored a projection-domain approach. Methods: Lesions were segmented from patient images and forward projected to acquire lesion projections. The forward-projection geometry was designed according to a commercial CT scanner and accommodated both axial and helical modes with various focal spot movement patterns. The energy employed by the commercial CT scanner for beam hardening correction was measured and used for the forward projection. The lesion projections were inserted into patient projections decoded from commercial CT projection data. The combined projections were formatted to match those of commercial CT raw data, loaded onto a commercial CT scanner, and reconstructed to create the hybrid images. Two validations were performed. First, to validate the accuracy of the forward-projection geometry, images were reconstructed from the forward projections of a virtual ACR phantom and compared to physically acquired ACR phantom images in terms of CT number accuracy and high-contrast resolution. Second, to validate the realism of the lesion in hybrid images, liver lesions were segmented from patient images and inserted back into the same patients, each at a new location specified by a radiologist. The inserted lesions were compared to the original lesions and visually assessed for realism by two experienced radiologists in a blinded fashion. Results: For the validation of the forward-projection geometry, the images reconstructed from the forward projections of the virtual ACR phantom were consistent with the images physically

  15. KOMPARASI NILAI BERITA TAYANGAN INFOTAINMENT INSERT DI TRANS TV DENGAN INTENS DI RCTI

    Directory of Open Access Journals (Sweden)

    Fidya Mulia Sari

    2015-11-01

    Full Text Available INSERT is an infotainment show that aired on Trans TV, various celebrities life events re-packaged and presented and the actual factual news with ease. While INTENSE is an infotainment program RCTI peel out on celebrity news. This study aims to determine the extent of the similarities and differences in the two infotainment news values are different, the infotainment Insert with Intense. From reliability test with formula Ole R. Holsti reliability figures obtained by 108% to the program while the program Insert Intense by 110%, which indicates that this research qualified objectivity. It can be deduced that the infotainment Insert has elements of news value exceptionalism while not intense, Intense Insert and both have elements of news value, insert more elements of news value has caused, and Intense Insert both have an element of actual news value, Insert and Intense not all the news has an element of closeness value, Insert has elements of information that is more than the value of Intense, Intense Insert and not all the news has an element of value conflict, Insert has the essential elements of news value is much, much more intense has an element of surprise news value than Intense, Insert has a lot more elements of human interest news value, and Insert or Intense equally newsworthy elements do not have sex.   INSERT adalah sebuah tayangan infotainment yang di tayangkan Trans TV, aneka kejadian kehidupan para selebriti kembali dikemas dan disajikan berita faktual dan aktual dengan santai. Sedangkan INTENS merupakan sebuah program tayangan infotainment RCTI yang mengupas habis tentang pemberitaan selebritis. Penelitian ini bertujuan untuk mengetahui sejauhmana persamaan dan perbedaan nilai berita pada kedua infotainment yang berbeda, yaitu infotainment Insert dengan Intens. Dari uji realibilitas dengan formula Ole R. Holsti didapatkan angka Realibilitas sebesar 108% untuk program Insert sedangkan program Intens sebesar 110% yang

  16. A comparison of screw insertion torque and pullout strength.

    Science.gov (United States)

    Ricci, William M; Tornetta, Paul; Petteys, Timothy; Gerlach, Darin; Cartner, Jacob; Walker, Zakiyyah; Russell, Thomas A

    2010-06-01

    Pullout strength of screws is a parameter used to evaluate plate screw fixation strength. However, screw fixation strength may be more closely related to its ability to generate sufficient insertion because stable nonlocked plate-screw fracture fixation requires sufficient compression between plate and bone such that no motion occurs between the plate and bone under physiological loads. Compression is generated by tightening of screws. In osteoporotic cancellous bone, sufficient screw insertion torque may not be generated before screw stripping. The effect of screw thread pitch on generation of maximum insertion torque (MIT) and pullout strength (POS) was investigated in an osteoporotic cancellous bone model and the relationship between MIT and POS was analyzed. Stainless steel screws with constant major (5.0 mm) and minor (2.7 mm) diameters but with varying thread pitches (1, 1.2, 1.5, 1.6, and 1.75 mm) were tested for MIT and POS in a validated osteoporotic surrogate for cancellous bone (density of 160 kg/m(3) [10 lbs/ft(3)]). MIT was measured with a torque-measuring hex driver for screws inserted through a one-third tubular plate. POS was measured after insertion of screws to a depth of 20 mm based on the Standard Specification and Test Methods for Metallic Medical Bone Screws (ASTM F 543-07). Five screws were tested for each failure mode and screw design. The relationship between MIT and compressive force between the plate and bone surrogate was evaluated using pressure-sensitive film. There was a significant difference in mean MIT based on screw pitch (P compression between the plate and bone surrogate was found for increasing screw torque (R(2) = 0.97). These results indicate that the ability of different screw designs to generate high screw insertion torque in a model of osteoporotic cancellous bone is unrelated to their pullout strength. Therefore, extrapolation of results for POS to identify optimal screw design for osteoporotic bone may not be valid

  17. Lithium insertion in the two crystallographic forms of the binary-phase Mo15Se19

    Science.gov (United States)

    Tarascon, J. M.; Murphy, D. W.

    1986-02-01

    Compounds which can undergo topotactic insertion of lithium are of potential technological importance in secondary lithium batteries. In this paper we present the chemical and electrochemical insertion of lithium into the binary-phase Mo15Se19, which can exist in two crystallographic forms, denoted AA and BB, when prepared from In3Mo15Se19 and In2Mo15Se19, respectively. We show that both forms can reversibly accommodate up to eight lithium atoms, yielding two new series of compounds of formula LixMo15Se19. This behavior is consistent with the electronic structure of the host material predicted from band-structure calculations. The room-temperature phase diagram of both LixMo15Se19 systems as a function of x has been established using electrochemical test cells (based on Mo15Se19 as the cathode), and in situ x-ray measurements as the cells discharge. Both LixMo15Se19 systems contain three single-phase domains as a function of x: two hexagonal phases and an orthorhombic phase. The nature of the transitions between these single phases and the variation of the lattice parameters within a single-phase domain are reported. While the mechanism of intercalation of lithium is similar for both Mo15Se19 forms, there is a drastic difference in Li intercalation behavior for the parent indium phases In2Mo15Se19 and In3Mo15Se19. We found that In2Mo15Se19 can reversibly incorporate 6.4 lithium atoms while In3Mo15Se19 does not react. This behavior is explained on the basis of structural considerations.

  18. Lithium insertion in the two crystallographic forms of the binary-phase Mo15Se19

    International Nuclear Information System (INIS)

    Tarascon, J.M.; Murphy, D.W.

    1986-01-01

    Compounds which can undergo topotactic insertion of lithium are of potential technological importance in secondary lithium batteries. In this paper we present the chemical and electrochemical insertion of lithium into the binary-phase Mo 15 Se 19 , which can exist in two crystallographic forms, denoted AA and BB, when prepared from In 3 Mo 15 Se 19 and In 2 Mo 15 Se 19 , respectively. We show that both forms can reversibly accommodate up to eight lithium atoms, yielding two new series of compounds of formula Li/sub x/Mo 15 Se 19 . This behavior is consistent with the electronic structure of the host material predicted from band-structure calculations. The room-temperature phase diagram of both Li/sub x/Mo 15 Se 19 systems as a function of x has been established using electrochemical test cells (based on Mo 15 Se 19 as the cathode), and in situ x-ray measurements as the cells discharge. Both Li/sub x/Mo 15 Se 19 systems contain three single-phase domains as a function of x: two hexagonal phases and an orthorhombic phase. The nature of the transitions between these single phases and the variation of the lattice parameters within a single-phase domain are reported. While the mechanism of intercalation of lithium is similar for both Mo 15 Se 19 forms, there is a drastic difference in Li intercalation behavior for the parent indium phases In''Mo 15 Se 19 and In 3 Mo 15 Se 19 . We found that In 2 Mo 15 Se 19 can reversibly incorporate 6.4 lithium atoms while In 3 Mo 15 Se 19 does not react. This behavior is explained on the basis of structural considerations

  19. Structure and orientation study of Ebola fusion peptide inserted in lipid membrane models.

    Science.gov (United States)

    Agopian, Audrey; Castano, Sabine

    2014-01-01

    The fusion peptide of Ebola virus comprises a highly hydrophobic sequence located downstream from the N-terminus of the glycoprotein GP2 responsible for virus-host membrane fusion. The internal fusion peptide of GP2 inserts into membranes of infected cell to mediate the viral and the host cell membrane fusion. Since the sequence length of Ebola fusion peptide is still not clear, we study in the present work the behavior of two fusion peptides of different lengths which were named EBO17 and EBO24 referring to their amino acid length. The secondary structure and orientation of both peptides in lipid model systems made of DMPC:DMPG:cholesterol:DMPE (6:2:5:3) were investigated using PMIRRAS and polarized ATR spectroscopy coupled with Brewster angle microscopy. The infrared results showed a structural flexibility of both fusion peptides which are able to transit reversibly from an α-helix to antiparallel β-sheets. Ellipsometry results corroborate together with isotherm measurements that EBO peptides interacting with lipid monolayer highly affected the lipid organization. When interacting with a single lipid bilayer, at low peptide content, EBO peptides insert as mostly α-helices mainly perpendicular into the lipid membrane thus tend to organize the lipid acyl chains. Inserted in multilamellar vesicles at higher peptide content, EBO peptides are mostly in β-sheet structures and induce a disorganization of the lipid chain order. In this paper, we show that the secondary structure of the Ebola fusion peptide is reversibly flexible between α-helical and β-sheet conformations, this feature being dependent on its concentration in lipids, eventually inducing membrane fusion. © 2013.

  20. Chick chorioallantoic membrane model for in ovo evaluation of timolol maleate-brimonidine tartrate ocular inserts.

    Science.gov (United States)

    Ravindran, Vinod Kombath; Repala, Swathi; Subadhra, Sandhya; Appapurapu, Ashok Kumar

    2014-06-01

    The main aspire of this study was to develop ocular drug delivery system for dual drug glaucoma therapy by timolol maleate-brimonidine tartrate and endeavor the possibility of biocompatibility studies by in ova studies. Matrix type, both hydrophilic and lipophilic polymers, and reservoir-type ocular inserts of timolol maleate were prepared using hydrophilic polymers like polyvinyl alcohol, hydroxyl propyl methyl cellulose K4M and lipophilic polymers like ethylcellulose and eudragit S100 and were optimized. Based on the optimized formulation, triple-layered ocular inserts (reservoir type) of dual drug were prepared by solvent casting technique with an objective of reducing the frequency of administration, obtaining controlled release and greater therapeutic efficacy, preservative free dosage form for the treatment of glaucoma. FTIR spectral studies revealed no pharmaceutical incompatibility and no drug polymer interactions. Maximum drug release (99.18 ± 1.7) was achieved when PVP and HPMC K4M in 1:1 ratio with PEG 400 (0.3 ml) drug reservoir layer was sandwiched between ethyl cellulose as rate control membrane up to 32 h in a controlled fashion. Drug release was by non-Fickian diffusion mechanism for single drug formulation. But in dual drug insert, timolol maleate best fit into zero order and for brimonidine tartrate to Higuchi model and diffusion of drugs from this by non-Fickian diffusion mechanism. In ovo studies suggested that the optimized formulation was found to be sterile, biocompatible and physicochemically stable and support us to claim that the developed formulation was biocompatible.

  1. Identification of new IS711 insertion sites in Brucella abortus field isolates

    Directory of Open Access Journals (Sweden)

    Moriyón Ignacio

    2011-08-01

    Full Text Available Abstract Background Brucellosis is a zoonosis caused by Brucella spp., a group of highly homogeneous bacteria. The insertion sequence IS711 is characteristic of these bacteria, and occurs in variable numbers and positions, but always constant within a given species. This species-associated polymorphism is used in molecular typing and identification. Field isolates of B. abortus, the most common species infecting cattle, typically carry seven IS711 copies (one truncated. Thus far, IS711 transposition has only been shown in vitro and only for B. ovis and B. pinnipedialis, two species carrying a high number of IS711 copies, but never in other Brucella species, neither in vitro nor in field strains. Results We found several B. abortus strains isolated from milk and aborted fetuses that carried additional IS711 copies in two hitherto undescribed insertion sites: one in an intergenic region near to the 3' end of a putative lactate permease gene and the other interrupting the sequence of a marR transcriptional regulator gene. Interestingly, the second type of insertion was identified in isolates obtained repeatedly from the same herd after successive brucellosis outbreaks, an observation that proves the stability and virulence of the new genotype under natural conditions. Sequence analyses revealed that the new copies probably resulted from the transposition of a single IS711 copy common to all Brucella species sequenced so far. Conclusions Our results show that the replicative transposition of IS711 can occur under field conditions. Therefore, it represents an active mechanism for the emergence of genetic diversity in B. abortus thus contributing to intra-species genetic polymorphism.

  2. Identification of new IS711 insertion sites in Brucella abortus field isolates.

    Science.gov (United States)

    Mancilla, Marcos; Ulloa, Marcos; López-Goñi, Ignacio; Moriyón, Ignacio; María Zárraga, Ana

    2011-08-03

    Brucellosis is a zoonosis caused by Brucella spp., a group of highly homogeneous bacteria. The insertion sequence IS711 is characteristic of these bacteria, and occurs in variable numbers and positions, but always constant within a given species. This species-associated polymorphism is used in molecular typing and identification. Field isolates of B. abortus, the most common species infecting cattle, typically carry seven IS711 copies (one truncated). Thus far, IS711 transposition has only been shown in vitro and only for B. ovis and B. pinnipedialis, two species carrying a high number of IS711 copies, but never in other Brucella species, neither in vitro nor in field strains. We found several B. abortus strains isolated from milk and aborted fetuses that carried additional IS711 copies in two hitherto undescribed insertion sites: one in an intergenic region near to the 3' end of a putative lactate permease gene and the other interrupting the sequence of a marR transcriptional regulator gene. Interestingly, the second type of insertion was identified in isolates obtained repeatedly from the same herd after successive brucellosis outbreaks, an observation that proves the stability and virulence of the new genotype under natural conditions. Sequence analyses revealed that the new copies probably resulted from the transposition of a single IS711 copy common to all Brucella species sequenced so far. Our results show that the replicative transposition of IS711 can occur under field conditions. Therefore, it represents an active mechanism for the emergence of genetic diversity in B. abortus thus contributing to intra-species genetic polymorphism.

  3. Effect of One versus Two Drain Insertion on Postoperative Seroma Formation after Modified Radical Mastectomy

    Directory of Open Access Journals (Sweden)

    farzaneh ebrahimifard

    2016-04-01

    Full Text Available Background: Modified radical mastectomy (MRM is still one of globally accepted surgical techniques for breast cancer and in some selected patient is the gold standard type of surgery. The most frequent complication of this procedure is seroma under skin flaps or in the axilla as reported as much as 30% in some studies. The use of closed suction drainage system to reduce the incidence of this complication has been routinely accepted by surgeons; however, length of catheter stay and the number of catheters inserted in the wound are still controversial. The present study compares the results of single versus double drain insertion in patients undergoing MRM for breast cancer.Materials and Methods: The study was conducted on 100 women with breast cancer who were candidate for MRM surgery during 2007-2010 referred to Modarres hospital, Tehran, Iran as a randomized group matched controlled trial.Results: There was no significant difference between the two groups in terms of age, BMI, and tumor weight (P=0.406 (Table 1. Similarly, the difference between the two groups was insignificant in tumor size (T and number of lymph nodes involved (P=0.145. There was no significant difference between the two groups in timing of axillary drain removal (P=0.064. No significant differences were observed between the two groups in mean aspirated fluid (P=0.071 and mean aspirated sera (P=0.484 after removal of drains.Conclusion: This study revealed one drain insertion in MRM surgery is as effective as two drain and probably less morbidity and cost.

  4. Chromaticity and low-β insertions in particle colliders

    Science.gov (United States)

    Autin, Bruno

    1990-12-01

    Besides its energy range, the main characteristic of a particle collider is its luminosity. A very important piece of equipment to achieve high luminosities is a low-β insertion, a device which focuses the beam down to a tiny spot size. The focusing limits are not only technological, they are also associated with the aberrations of such systems. This paper deals with the chromatic aberrations. In a first part, the treatment of the focusing errors is reviewed and a formalism using symbolic computation is set up so that high-order perturbations can be evaluated, although results are limited to the second-order betatron tune shift and to its interpretation. In a second part, a completely analytical theory of the final doublet of a low-β insertion is given for a special model of flat-beam focusing.

  5. First two barrel ECAL supermodules inserted in CMS HCAL

    CERN Multimedia

    K.Bell

    2006-01-01

    The first two barrel "supermodules" for the CMS Electromagnetic Calorimeter (ECAL) have been inserted into the barrel hadron calorimeter (HCAL) in the experimental hall (called SX5) in Cessy in preparation for the forthcoming magnet test and cosmic challenge (MTCC). Each of the two supermodules contains 1700 lead tungstate crystals in glass-fibre alveolar support structures, with associated avalanche photodiodes (APDs, for scintillation light detection), electronics and cooling system. The barrel ECAL will consist of 36 supermodules, many of which have already been produced (see CERN Bulletin 17-18, 2006). Team from CMS ECAL, CMS Integration and CEA-DAPNIA were involved in the insertion, with the production/integration of the supermodules themselves involving many technicians, engineers and physicists from many institutes. From left to right: Olivier Teller, Maf Alidra and Lucien Veillet.

  6. Mediastinal abscess and esophageal stricture following voice prosthesis insertion.

    Science.gov (United States)

    Bozzo, Corrado; Meloni, Francesco; Trignano, Mario; Profili, Stefano

    2014-04-01

    The use of a tracheo-esophageal voice prosthesis is a well-established procedure to restore the voice in total laryngectomees. The insertion of the prosthesis is not a risk-free procedure, various complications having been reported especially in irradiated patients. Here described is a case of an esophageal rupture after secondary tracheo-esophageal puncture with mediastinal abscess in a patient previously treated with pharyngo-laryngectomy and subsequent radiotherapy for a left pyriform sinus carcinoma, which required immediate surgical drainage through a left cervical approach. Few weeks after surgical drainage an esophageal stricture at the site of the rupture developed, which was only temporarily resolved after the insertion of biodegradable esophageal stents, followed by re-stenosis once the reabsorption of the stent took place. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  7. Insertion sequences enrichment in extreme Red sea brine pool vent

    KAUST Repository

    Elbehery, Ali H. A.

    2016-12-03

    Mobile genetic elements are major agents of genome diversification and evolution. Limited studies addressed their characteristics, including abundance, and role in extreme habitats. One of the rare natural habitats exposed to multiple-extreme conditions, including high temperature, salinity and concentration of heavy metals, are the Red Sea brine pools. We assessed the abundance and distribution of different mobile genetic elements in four Red Sea brine pools including the world’s largest known multiple-extreme deep-sea environment, the Red Sea Atlantis II Deep. We report a gradient in the abundance of mobile genetic elements, dramatically increasing in the harshest environment of the pool. Additionally, we identified a strong association between the abundance of insertion sequences and extreme conditions, being highest in the harshest and deepest layer of the Red Sea Atlantis II Deep. Our comparative analyses of mobile genetic elements in secluded, extreme and relatively non-extreme environments, suggest that insertion sequences predominantly contribute to polyextremophiles genome plasticity.

  8. Amyloid protein unfolding and insertion kinetics on neuronal membrane mimics

    Science.gov (United States)

    Qiu, Liming; Buie, Creighton; Vaughn, Mark; Cheng, Kwan

    2010-03-01

    Atomistic details of beta-amyloid (Aβ ) protein unfolding and lipid interaction kinetics mediated by the neuronal membrane surface are important for developing new therapeutic strategies to prevent and cure Alzheimer's disease. Using all-atom MD simulations, we explored the early unfolding and insertion kinetics of 40 and 42 residue long Aβ in binary lipid mixtures with and without cholesterol that mimic the cholesterol-depleted and cholesterol-enriched lipid nanodomains of neurons. The protein conformational transition kinetics was evaluated from the secondary structure profile versus simulation time plot. The extent of membrane disruption was examined by the calculated order parameters of lipid acyl chains and cholesterol fused rings as well as the density profiles of water and lipid headgroups at defined regions across the lipid bilayer from our simulations. Our results revealed that both the cholesterol content and the length of the protein affect the protein-insertion and membrane stability in our model lipid bilayer systems.

  9. Impact of hydrogen insertion on vehicular natural gas

    Energy Technology Data Exchange (ETDEWEB)

    Strangueto, Karina Maretti; Silva, Ennio Peres da [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Fac. of Mechanical Engineering. Energy Dept.], Email: karinakms@fem.unicamp.br

    2010-07-01

    This article aims to analyze the possibility of insertion of hydrogen in the vehicular natural gas or even the insertion of the hydrogen in the compressed natural gas used in Brazil. For the production of this hydrogen, the spilled turbinable energy from Itaipu would be harnessed. The calculation of production can be extended to other power plants which are close to the natural gas pipelines, where the hydrogen would be introduced. Then, it was analyzed the consumption of natural gas in vehicles in Brazil, the regulation of transportation, the sales of compressed natural gas to fuelling station, the specifications that the piped gas should follow to be sold, and how much hydrogen could be accepted in the mix. (author)

  10. Chromaticity and low-β insertions in particle colliders

    International Nuclear Information System (INIS)

    Autin, B.

    1990-01-01

    Besides its energy range, the main characteristic of a particle collider is its luminosity. A very important piece of equipment to achieve high luminosities is a low-β insertion, a device which focuses the beam down to a tiny spot size. The focusing limits are not only technological, they are also associated with the aberrations of such systems. This paper deals with the chromatic aberrations. In a first part, the treatment of the focusing errors is reviewed and a formalism using symbolic computation is set up so that high-order perturbations can be evaluated, although results are limited to the second-order betatron tune shift and to its interpretation. In a second part, a completely analytical theory of the final doublet of a low-β insertion is given for a special model of flat-beam focusing. (orig.)

  11. A morphophonological analysis of the velar insert in Italian verbs

    Directory of Open Access Journals (Sweden)

    Nicola Lampitelli

    2017-05-01

    Full Text Available This paper analyzes a particular group of Italian irregular verbs that are characterized by the insertion of [g] between the root and the inflectional markers. Despite the apparent unetymological status of such a velar insert (Rohlfs 1968, it is shown that the allomorphy of the root depends on the internal organization of the segmental material with respect to a fixed template made of a strict alternation of onsets (C and nuclei (V. The analyses are couched within the CVCV framework (Lowenstamm 1996; Scheer 2004 and are consistent with a syntactic approach to word- formation such as Distributed Morphology (Halle & Marantz 1993; Embick 2010. This article is part of the special collection: Motivating Form in Morpho-Syntax

  12. Challenges for Insertion of Structural Nanomaterials in Aerospace Applications

    Science.gov (United States)

    Sochi, Emilie J.

    2012-01-01

    In the two decades since Iijima's report on carbon nanotubes (CNT), there has been great interest in realizing the benefits of mechanical properties observed at the nanoscale in large-scale structures. The weight savings possible due to dramatic improvements in mechanical properties relative to state-of-the-art material systems can be game changing for applications like aerospace vehicles. While there has been significant progress in commercial production of CNTs, major aerospace applications that take advantage of properties offered by this material have yet to be realized. This paper provides a perspective on the technical challenges and barriers for insertion of CNTs as an emerging material technology in aerospace applications and proposes approaches that may reduce the typical timeframe for technology maturation and insertion into aerospace structures.

  13. Magnetic resonance urography in duplex kidney with ectopic ureteral insertion

    Directory of Open Access Journals (Sweden)

    Conjeevaram Rajendrarao Thambidorai

    2011-01-01

    Full Text Available This is a report on the use of magnetic resonance urography (MRU in a 6-year-old girl who presented with urinary incontinence. She had a left duplex kidney with poorly functioning upper moiety and ectopic insertion of the dilated upper pole ureter. MRU has been shown to be superior to conventional imaging techniques in delineating poorly functioning moieties of duplex kidneys and ectopic ureters.

  14. Technology Insertion and Management: Options for the Canadian Forces

    Science.gov (United States)

    2010-01-01

    Technology Insertion and Management : Options for the Canadian Forces Mike Stocker Defence Economics Team Defence R&D Canada... Management Options for the Canadian Forces Mike Stocker Defence Economics Team The reported results, their interpretation, and any...semble indiquer qu’un changement de paradigme est en cours dans la façon dont les militaires élaborent et emploient la technologie à utiliser avec leurs

  15. ISR Superconducting High-Luminosity (low beta ) insertion

    CERN Multimedia

    CERN PhotoLab

    1981-01-01

    The photograph shows two of the 8 Superconducting Quadrupoles installed in ISR intersection I8 with their helium supply flexible lines,vacuum equipment,power and signal cables. The increase of luminosity produced by this insertion was above a factor 7. On the right one can see part of Open-Axial-Field Magnet. The person on the left side is Stephan Pichler. See also photo 7702690 and its abstract.

  16. Right pleural insertion of a small bore feeding tube

    Directory of Open Access Journals (Sweden)

    Robbins RA

    2011-06-01

    Full Text Available We report a case of a 56 year old man who had a feeding tube inadvertently malpositioned into the right pleural space and had approximately 600 ml of tube feedings infused. After the malposition was recognized, the patient underwent chest tube placement, followed by video assisted thoracic surgery 5 days later. He made an uneventful recovery. The case illustrates the problems with identification and treating feeding tube insertion into the lung.

  17. Right pleural insertion of a small bore feeding tube

    OpenAIRE

    Robbins RA; Glenn T; Singarajah CU

    2011-01-01

    We report a case of a 56 year old man who had a feeding tube inadvertently malpositioned into the right pleural space and had approximately 600 ml of tube feedings infused. After the malposition was recognized, the patient underwent chest tube placement, followed by video assisted thoracic surgery 5 days later. He made an uneventful recovery. The case illustrates the problems with identification and treating feeding tube insertion into the lung.

  18. Insertion of cations into WO3 investigated by QCM techniques

    Czech Academy of Sciences Publication Activity Database

    Vondrák, Jiří; Sedlaříková, M.; Velická, Jana; Špičák, P.; Svoboda, V.; Kazelle, J.

    2007-01-01

    Roč. 11, č. 10 (2007), s. 1459-1462 ISSN 1432-8488 R&D Projects: GA MŽP SN/3/171/05; GA AV ČR(CZ) KJB208130604; GA ČR(CZ) GA104/06/1471 Institutional research plan: CEZ:AV0Z40320502 Keywords : tungsten trioxide * insertion of cations * quartz crystal microbalance Subject RIV: CG - Electrochemistry Impact factor: 1.535, year: 2007

  19. Peripherally inserted central catheter (PICC) complications during pregnancy.

    Science.gov (United States)

    Cape, Alison V; Mogensen, Kris M; Robinson, Malcolm K; Carusi, Daniela A

    2014-07-01

    Peripherally inserted central catheters (PICCs) are routinely used in women with hyperemesis gravidarum. However, little is known about the consequences of PICC insertion in these patients. Our aim was to analyze PICC-related complication rates among pregnant women. Pregnant women with PICC insertion between January 2000 and June 2006 were studied retrospectively. Infusate type, comorbid conditions, and PICC duration were characterized. Major complications, defined as need for surgical intervention, bacteremia requiring intravenous antibiotics, or thromboembolic events, were identified. Minor complications, including phlebitis, PICC malfunction, early PICC removal, infection requiring oral antibiotics, or hospitalization for PICC evaluation, were also studied. Eighty-four catheters in 66 women were eligible for study, totaling 2544 PICC days. Catheters remained in place for 1-177 days; median duration was 21.0 days. PICCs were used for intravenous fluid (IVF, 59.4%), parenteral nutrition (PN, 34.5%), and antibiotics (6%). The overall complication rate was 18.5 per 1000 PICC days (55.9% of PICCs); 22.6% were major, with bacteremia being most frequent (20.2%). A diagnosis of diabetes was the only factor that significantly predicted complications (hazard ratio, 2.71; 95% confidence interval, 1.13-6.13). PICC duration and type of infusate (PN vs IVF alone) were not associated with complications. PICC insertion in pregnant women is associated with a high complication rate, which appears to be independent of the type of infusate and occurs in the majority of women. PICCs should be used judiciously and only when clearly necessary during pregnancy. Further studies are needed to determine how to reduce PICC-related complications in this population. © 2013 American Society for Parenteral and Enteral Nutrition.

  20. Effects of tools inserted through snake-like surgical manipulators.

    Science.gov (United States)

    Murphy, Ryan J; Otake, Yoshito; Wolfe, Kevin C; Taylor, Russell H; Armand, Mehran

    2014-01-01

    Snake-like manipulators with a large, open lumen can offer improved treatment alternatives for minimally-and less-invasive surgeries. In these procedures, surgeons use the manipulator to introduce and control flexible tools in the surgical environment. This paper describes a predictive algorithm for estimating manipulator configuration given tip position for nonconstant curvature, cable-driven manipulators using energy minimization. During experimental bending of the manipulator with and without a tool inserted in its lumen, images were recorded from an overhead camera in conjunction with actuation cable tension and length. To investigate the accuracy, the estimated manipulator configuration from the model and the ground-truth configuration measured from the image were compared. Additional analysis focused on the response differences for the manipulator with and without a tool inserted through the lumen. Results indicate that the energy minimization model predicts manipulator configuration with an error of 0.24 ± 0.22mm without tools in the lumen and 0.24 ± 0.19mm with tools in the lumen (no significant difference, p = 0.81). Moreover, tools did not introduce noticeable perturbations in the manipulator trajectory; however, there was an increase in requisite force required to reach a configuration. These results support the use of the proposed estimation method for calculating the shape of the manipulator with an tool inserted in its lumen when an accuracy range of at least 1mm is required.

  1. Peripherally inserted central catheters and upper extremity deep vein thrombosis

    International Nuclear Information System (INIS)

    Ong, B.; Gibbs, H.; Catchpole, I.; Hetherington, R.; Harper, J.

    2006-01-01

    The purpose of the study was to determine the incidence and risk factors for venous thrombosis in patients with a peripherally inserted central catheter (PICC). A retrospective study of all upper extremity venous duplex scans was carried out in the Vascular Medicine department from year 2000 to 2002 inclusive. A chart review of positive scans was undertaken to identify possible thrombotic risk factors. Of 317 upper extremity venous duplex scans carried out, 115, or 32%, were positive for upper extremity deep vein thrombosis. Three main risk factors were identified - presence of a central line, malignancy and administration of chemotherapy. PICC were the most common central line present. Symptomatic thrombosis occurred in 7% of PICC inserted for chemotherapy compared with 1% of PICC inserted for other reasons. Ten per cent of the patients receiving chemotherapy through a PICC developed a thrombosis. The post-thrombotic syndrome was infrequent following upper extremity deep vein thrombosis. Patients receiving chemotherapy through a PICC are at increased risk of thrombosis. There may be a role for prophylactic low-dose anticoagulation in these high-risk patients

  2. ADC's Insertion Devices and Magnetic Measurement Systems Capabilities

    Science.gov (United States)

    Deyhim, A.; Kulesza, J.

    2013-03-01

    In this paper Advance Design Consulting USA, Inc. (ADC) will discuss ADC's major improved capabilities for building Wiggler Insertion Devices, Undulator Planar Devices, Elliptical Polarizing Undulators (EPU), In-Vacuum Undulators (IVU), Cryogenically Cooled in-vacuum Undulators (CPMU), Super Conductive Undulator, and Insertion Device Magnetic Measurement Systems. ADC has designed, built and delivered Insertion Devices and Magnetic Measurement Systems to such facilities as MAX-lab (two EPUs, a Planar, and Measurement System), ALBA and ASP (Wigglers), BNL (CPMU), SSRF (two IVUs and a Measurement System), PAL (one IVU and Measurement System), NSRRC (one 4m EPU), and SRC (Planar and EPU). ADC's magnetic field measurement system is a sophisticated and sensitive machine for the measurement of magnetic fields in undulators (Planar and EPU), wigglers and in-vacuum ID units. The magnetic fields are measured using 3 axis hall-effect probes, mounted orthogonally, to a thin wand. The wand is mounted to a carriage that rides on vacuum air bearings. The base is granite. A flip coil is provided on two vertical towers with X, Y and Theta axes. Special software is provided to assist in homing, movement, and data collection and analysis.

  3. Development of Needle Insertion Manipulator for Central Venous Catheterization

    Science.gov (United States)

    Kobayashi, Yo; Hong, Jaesung; Hamano, Ryutaro; Hashizume, Makoto; Okada, Kaoru; Fujie, Masakatsu G.

    Central venous catheterization is a procedure, which a doctor insert a catheter into the patient’s vein for transfusion. Since there are risks of bleeding from arterial puncture or pneumothorax from pleural puncture. Physicians are strictly required to make needle reach up into the vein and to stop the needle in the middle of vein. We proposed a robot system for assisting the venous puncture, which can relieve the difficulties in conventional procedure, and the risks of complication. This paper reports the design structuring and experimental results of needle insertion manipulator. First, we investigated the relationship between insertion force and angle into the vein. The results indicated that the judgment of perforation using the reaction force is possible in case where the needling angle is from 10 to 20 degree. The experiment to evaluate accuracy of the robot also revealed that it has beyond 0.5 mm accuracy. We also evaluated the positioning accuracy in the ultrasound images. The results displays that the accuracy is beyond 1.0 mm and it has enough for venous puncture. We also carried out the venous puncture experiment to the phantom and confirm our manipulator realized to make needle reach up into the vein.

  4. Insertion of pedagogical activities mediated by ICT in literacy

    Directory of Open Access Journals (Sweden)

    Lúcia Margarete Santos da Costa

    2016-12-01

    Full Text Available This article is cut out of a research dissertation entitled "Educational activities insertion mediated by ICT literacy. This study aimed to implement such activities promoting the integration of ICT as an aid in the literacy process in a primary education school (EF of Santa Maria and had as participants the students of the 3rd year. In this survey we present results of the activities of insertion mediated by E-book technology. Therefore we sought theoretical foundation in authors like Ferreira and Teberoscky (1999, Freire (1989, 1996, Mendonça and Mendonça (2008 and other authors who contribute to the theme. The methodology used was action research that enables the construction of knowledge through practice, reflection-action and intervention in school reality. This study is linked to the line of research "Educational Technologies in Management Network", Federal University of Santa Maria. The results showed that the ICT e-book inserted in literacy contributed significantly to the advancement of learning reading, writing and the development of various skills as well as to build the autonomy of collaboration and cooperation among students considering the teacher as an important articulator and mediator interactions.

  5. Development of an ultrasound-guided PICC insertion service.

    Science.gov (United States)

    Nicholson, Jackie

    Use of the peripherally inserted central catheter (PICC) has gained popularity over the past 30 years in the USA and over the past 15 years in the UK. The PICC was initially used for specific purposes, such as the delivery of parenteral nutrition and chemotherapy, but its use has expanded both within the acute hospital and community settings. This article describes an ultrasound-guided PICC insertion service that has been set up in a district general hospital to expand the service within the oncology department and to begin a service for non-oncology patients. As expected, patients who have benefited from the development of this service include those requiring parenteral nutrition, chemotherapy and intravenous therapy in the community. However, retrospective audit has shown that the largest group of patients to benefit from the ultrasound-guided PICC insertion service was those with difficult venous access for a variety of reasons. Some of these reasons are discussed, along with an overview of the benefits the service has provided to other groups of patients, and associated benefits to the hospital trust.

  6. Risk factors for development of complication following peripherally inserted central

    Directory of Open Access Journals (Sweden)

    Hakan Aydın

    2014-03-01

    Full Text Available Objectives: Peripherally inserted central venous catheters (PICCs are inserted into central veins through the upper extremity veins. In this retrospective study, we aimed to evaluate PICC procedures, related complications, their causes and factors influencing the success of the procedure during anaesthesia Methods: ‘Central Venous Catheterization Forms’ filled out for 850 patients in whom a PICC was inserted by residents during general anaesthesia between November 2009 and March 2013 in the operating room of Uludag University Medical Faculty Hospital were retrospectively analysed. Results: A total of 1174 procedures were evaluated. The most preferred vein for the first attempt was the right basilic vein (32.7%. Difficulty (more than two attempts with the PICC procedure was correlated with the patient’s age (p30 kg/m² (p<0.05, resident with less than 4 years of training (p=0.001, number of PICC attempts ≥2 (p<0.001, more than one resident involved in the catheterization procedure (p<0.001 and previous failed PICC procedures (p<0.001. Conclusion: We conclude that catheterization should be performed under the surveillance of a staff keeping in mind the risks of complications. In the case of failure following 2 attempts, the procedure should be handed over to a more experienced staff member. J Clin Exp Invest 2014; 5 (1: 29-35

  7. NURSING CARE IN PATIENTS NEONATES WITH PERIPHERALLY INSERTED CENTRAL CATHETER

    Directory of Open Access Journals (Sweden)

    Anacilda Oliveira Vieira

    2013-12-01

    Full Text Available Introduction: The PICC (peripherally inserted central catheter is a long flexible catheter which is inserted through a peripheral vein, progresses through a needle introducer until the final portion of the vena cava, acquiring characteristics of a central catheter. Objective: To point out the main theoretical and scientific ideas that demonstrate the reliability, competence and ability of nurses to perform the PICC. Methodology: Systematic review of articles, which were found by searching the database scientific journals and bibliographies area. Results: The success of integration depends on the patient assessment and choice of venous access where the catheter will be positioned, and its tip should be in the middle third of the superior vena cava, or the middle third of the inferior vena cava. In neonates, which are used more frequently, proper positioning of the catheter is through nursing care in making the dressing, and the first 24 hours it should be compressive. Ideally, the PICC remains in the vein for periods longer than seven days or until the end of treatment, thus decreasing invasive procedures. Conclusion: According to the Federal Board of Nursing (COFEN, it is lawful for the insertion of PICC nurses, provided it has undergone professional training.

  8. Enhancement of Hole Confinement by Monolayer Insertion in Asymmetric Quantum-Barrier UVB Light Emitting Diodes

    KAUST Repository

    Janjua, Bilal

    2014-04-01

    We study the enhanced hole confinement by having a large bandgap AlGaN monolayer insertion (MLI) between the quantum well (QW) and the quantum barrier (QB). The numerical analysis examines the energy band alignment diagrams, using a self-consistent 6 × 6 k ·p method and, considering carrier distribution, recombination rates (Shockley-Reed-Hall, Auger, and radiative recombination rates), under equilibrium and forward bias conditions. The active region is based on AlaGa1-aN (barrier)/AlbGa1-bN (MLI)/AlcGa1-cN (well)/AldGa1-dN (barrier), where b > d > a > c. A large bandgap AlbGa1-bN mono layer, inserted between the QW and QB, was found to be effective in providing stronger hole confinement. With the proposed band engineering scheme, an increase of more than 30% in spatial overlap of carrier wavefunction was obtained, with a considerable increase in carrier density and direct radiative recombination rates. The single-QW-based UV-LED was designed to emit at 280 nm, which is an effective wavelength for water disinfection.

  9. Percutaneous Endoscopic Gastrostomy Tube Insertion in Neurodegenerative Disease: A Retrospective Study and Literature Review.

    Science.gov (United States)

    Sarkar, Pamela; Cole, Alice; Scolding, Neil J; Rice, Claire M

    2017-05-01

    With the notable exceptions of dementia, stroke, and motor neuron disease, relatively little is known about the safety and utility of percutaneous endoscopic gastrostomy (PEG) tube insertion in patients with neurodegenerative disease. We aimed to determine the safety and utility of PEG feeding in the context of neurodegenerative disease and to complete a literature review in order to identify whether particular factors need to be considered to improve safety and outcome. A retrospective case note review of patients referred for PEG insertion by neurologists in a single neuroscience center was conducted according to a pre-determined set of standards. For the literature review, we identified references from searches of PubMed, mainly with the search items "percutaneous endoscopic gastrostomy" and "neurology" or "neurodegenerative disease." Short-term mortality and morbidity associated with PEG in patients with neurological disease were significant. Age greater than 75 years was associated with poor outcome, and a trend toward adverse outcome was observed in patients with low serum albumin. This study highlights the relatively high risk of PEG in patients with neurodegenerative disease. We present points for consideration to improve outcome in this particularly vulnerable group of patients.

  10. Molecular evaluation of a novel missense mutation & an insertional truncating mutation in SUMF1 gene

    Directory of Open Access Journals (Sweden)

    Udhaya H Kotecha

    2014-01-01

    Full Text Available Background & objectives: Multiple suphphatase deficiency (MSD is an autosomal recessive disorder affecting the post translational activation of all enzymes of the sulphatase family. To date, approximately 30 different mutations have been identified in the causative gene, sulfatase modifying factor 1 (SUMF1. We describe here the mutation analysis of a case of MSD. Methods: The proband was a four year old boy with developmental delay followed by neuroregression. He had coarse facies, appendicular hypertonia, truncal ataxia and ichthyosis limited to both lower limbs. Radiographs showed dysostosis multiplex. Clinical suspicion of MSD was confirmed by enzyme analysis of four enzymes of the sulphatase group. Results: The patient was compound heterozygote for a c.451A>G (p.K151E substitution in exon 3 and a single base insertion mutation (c.690_691 InsT in exon 5 in the SUMF1 gene. The bioinformatic analysis of the missense mutation revealed no apparent effect on the overall structure. However, the mutated 151-amino acid residue was found to be adjacent to the substrate binding and the active site residues, thereby affecting the substrate binding and/or catalytic activity, resulting in almost complete loss of enzyme function. Conclusions: The two mutations identified in the present case were novel. This is perhaps the first report of an insertion mutation in SUMF1 causing premature truncation of the protein.

  11. Development of an Insert Co-culture System of Two Cellular Types in the Absence of Cell-Cell Contact.

    Science.gov (United States)

    Renaud, Justine; Martinoli, Maria-Grazia

    2016-07-17

    The role of secreted soluble factors in the modification of cellular responses is a recurrent theme in the study of all tissues and systems. In an attempt to make straightforward the very complex relationships between the several cellular subtypes that compose multicellular organisms, in vitro techniques have been developed to help researchers acquire a detailed understanding of single cell populations. One of these techniques uses inserts with a permeable membrane allowing secreted soluble factors to diffuse. Thus, a population of cells grown in inserts can be co-cultured in a well or dish containing a different cell type for evaluating cellular changes following paracrine signaling in the absence of cell-cell contact. Such insert co-culture systems offer various advantages over other co-culture techniques, namely bidirectional signaling, conserved cell polarity and population-specific detection of cellular changes. In addition to being utilized in the field of inflammation, cancer, angiogenesis and differentiation, these co-culture systems are of prime importance in the study of the intricate relationships that exist between the different cellular subtypes present in the central nervous system, particularly in the context of neuroinflammation. This article offers general methodological guidelines in order to set up an experiment in order to evaluating cellular changes mediated by secreted soluble factors using an insert co-culture system. Moreover, a specific protocol to measure the neuroinflammatory effects of cytokines secreted by lipopolysaccharide-activated N9 microglia on neuronal PC12 cells will be detailed, offering a concrete understanding of insert co-culture methodology.

  12. SU-E-T-64: A Programmable Moving Insert for the ArcCHECK Phantom for Dose Verification of Respiratory-Gated VMAT

    Energy Technology Data Exchange (ETDEWEB)

    Gaede, S; Jordan, K [London Regional Cancer Program, London, ON (United Kingdom); Western University, London, ON (United Kingdom); Young, H [University of Waterloo, Waterloo, ON (Canada); Mulligan, M [London Regional Cancer Program, London, ON (United Kingdom)

    2015-06-15

    Purpose: To present a customized programmable moving insert for the ArcCHECK™ phantom that can, in a single delivery, check both entrance dosimetry, while simultaneously verifying the delivery of respiratory-gated VMAT. Methods: The cylindrical motion phantom uses a computer-controlled stepping motor to move an insert inside a stationery sleeve. Insert motion is programmable and can include rotational motion in addition to linear motion along the axis of the cylinder. The sleeve fits securely in the bore of the ArcCHECK™. Interchangeable inserts, including an A1SL chamber, optically-stimulated luminescence dosimeters, radiochromic film, or 3D gels, allow this combination to be used for commissioning, routine quality assurance, and patient-specific dosimetric verification of respiratory-gated VMAT. Before clinical implementation, the effect of a moving insert on the ArcCHECK™ measurements was considered. First, the measured dose to the ArcCHECK™ containing multiple inserts in the static position was compared to the calculated dose during multiple VMAT treatment deliveries. Then, dose was measured under both sinusoidal and real-patient motion conditions to determine any effect of the moving inserts on the ArcCHECK™ measurements. Finally, dose was measured during gated VMAT delivery to the same inserts under the same motion conditions to examine any effect of various beam “on-and-off” and dose rate ramp “up-and-down”. Multiple comparisons between measured and calculated dose to different inserts were also considered. Results: The pass rate for the static delivery exceeded 98% for all measurements (3%/3mm), suggesting a valid setup for entrance dosimetry. The pass rate was not altered for any measurement delivered under motion conditions. A similar Result was observed under gated VMAT conditions, including agreement of measured and calculated dose to the various inserts. Conclusion: Incorporating a programmable moving insert within the Arc

  13. xenoGI: reconstructing the history of genomic island insertions in clades of closely related bacteria.

    Science.gov (United States)

    Bush, Eliot C; Clark, Anne E; DeRanek, Carissa A; Eng, Alexander; Forman, Juliet; Heath, Kevin; Lee, Alexander B; Stoebel, Daniel M; Wang, Zunyan; Wilber, Matthew; Wu, Helen

    2018-02-05

    Genomic islands play an important role in microbial genome evolution, providing a mechanism for strains to adapt to new ecological conditions. A variety of computational methods, both genome-composition based and comparative, have been developed to identify them. Some of these methods are explicitly designed to work in single strains, while others make use of multiple strains. In general, existing methods do not identify islands in the context of the phylogeny in which they evolved. Even multiple strain approaches are best suited to identifying genomic islands that are present in one strain but absent in others. They do not automatically recognize islands which are shared between some strains in the clade or determine the branch on which these islands inserted within the phylogenetic tree. We have developed a software package, xenoGI, that identifies genomic islands and maps their origin within a clade of closely related bacteria, determining which branch they inserted on. It takes as input a set of sequenced genomes and a tree specifying their phylogenetic relationships. Making heavy use of synteny information, the package builds gene families in a species-tree-aware way, and then attempts to combine into islands those families whose members are adjacent and whose most recent common ancestor is shared. The package provides a variety of text-based analysis functions, as well as the ability to export genomic islands into formats suitable for viewing in a genome browser. We demonstrate the capabilities of the package with several examples from enteric bacteria, including an examination of the evolution of the acid fitness island in the genus Escherichia. In addition we use output from simulations and a set of known genomic islands from the literature to show that xenoGI can accurately identify genomic islands and place them on a phylogenetic tree. xenoGI is an effective tool for studying the history of genomic island insertions in a clade of microbes. It identifies

  14. Test manufacturing of copper canisters with cast inserts. Assessment report

    International Nuclear Information System (INIS)

    Andersson, C.G.

    1998-08-01

    The current design of canisters for the deep repository for spent nuclear fuel consists of an outer corrosion-protective copper casing in the form of a tubular section with lid and bottom and an inner pressure-resistant insert. The insert is designed to be manufactured by casting and inside are channels in which the fuel assemblies are to be placed. Over the last years, a number of full-scale manufacturing tests of all canister components have been carried out. The purpose has been to determine and develop the best manufacturing technique and to establish long-term contacts with the best suppliers of material and technology. Part of the work has involved the developing and implementing of a quality assurance system in accordance with ISO 9001, covering the whole chain from suppliers of material up to and including the delivery of assembled canisters. This report consists of a description of the design of the canister together with current drawings and complementary technical specifications stipulating, among other things, requirements placed on different materials. The different manufacturing methods that have been used are also described and commented on in both text and illustrations. For the manufacturing of copper tubes, the roll-forming of rolled plate to tube halves and longitudinal welding is a method that has been tested on a relatively large number of tubes by now, and that probably can be developed into a functioning production method. However, the very promising outcome of performed tests on seamless tube manufacturing, has resulted in a change in direction in tube manufacturing, focusing on continued testing of extrusion as well as pierce and draw processing in the immediate future. In connection with ongoing operations, new manufacturing tests of tubes with less material thickness will be carried out. Test manufacturing of cast inserts has resulted in the choice of nodular iron as material in the continued work. This improvement in design has resulted

  15. Novel Principles of Gamma-Retroviral Insertional Transcription Activation in Murine Leukemia Virus-induced End-stage Tumors

    DEFF Research Database (Denmark)

    Sokol, Martin; Wabl, Matthias; Rius Ruiz, Irene

    2014-01-01

    Background Insertional mutagenesis screens of retrovirus-induced mouse tumors have proven valuable in human cancer research and for understanding adverse effects of retroviral-based gene therapies. In previous studies, the assignment of mouse genes to individual retroviral integration sites has...... on opposite DNA strands; tandem-type activation of distal genes that are positioned adjacently on the same DNA strand; activation of genes that are not the direct integration targets; combination-type insertional mutagenesis, in which enhancer activation, alternative chimeric splicing and retroviral promoter...... transcription activation patterns that reach beyond a single and nearest annotated gene target. Awareness of this previously undescribed layer of complexity may prove important for elucidation of adverse effects in retroviral-based gene therapies. We also show that wild-type gamma-retroviruses are frequently...

  16. Biomechanical simulation of needle insertion into cornea based on distortion energy failure criterion.

    Science.gov (United States)

    Su, Peng; Yang, Yang; Zhang, Leiyu; Huang, Long

    2016-01-01

    This paper is mainly about biomechanical behavior of needle insertion into cornea, and proposes a failure criterion to simulate the insertion process which has attracted considerable attention due to its importance for the minimally invasive treatment. In the process of needle insertion into cornea, tiny and complex insertion force is generated due to contact between needle and soft tissue. Based on the distortion energy theory, there is proposed a failure criterion of corneal material that can solve contact problem between rigid body and biological tissue in insertion simulation, where Cauchy stress of corneal material is the key to numerical calculation. A finite element model of in vivo cornea is built, and the cornea constrained by sclera is simplified to two layers containing epithelium and stroma. Considering the hyper-viscoelastic property of corneal material, insertion simulation is carried out. By insertion experiment, the insertion force increases with insertion depth accompanying obvious fluctuations. Different insertion forces are generated at different speeds. The punctured locations are obvious in the force-displacement curves. The results of insertion simulation are generally consistent with experimental data. Maps of von Mises stress reflect the tissue injury of the cornea during insertion process, and punctured status corresponds to the point in the curves. The ability of this study to reproduce the behavior of needle insertion into cornea opens a promising perspective for the control of robotic surgery operation as well as the real-time simulation of corneal suture surgery.

  17. Decline of Low-Frequency Hearing in People With Ski-Slope Hearing Loss; Implications for Electrode Array Insertion.

    Science.gov (United States)

    Schuurbiers, Jasper; Dingemanse, Gertjan; Metselaar, Mick

    2017-12-01

    The decline of low-frequency hearing in people with ski-slope hearing loss varies and might depend on etiology. People with ski-sloping hearing loss might benefit from cochlear implantation with preservation of residual hearing. To reduce the risk of losing low-frequency hearing after implantation, the electrode-array can be inserted partially up to the desired frequency. That, however, obstructs electrical stimulation of lower frequencies. To decide between complete or partial insertion, knowledge regarding the natural decline of low-frequency hearing is helpful. Patients with at least two ski-slope audiograms over time were selected. We calculated progression at lower frequencies for 320 patients. Etiologies for hearing loss were retrieved from medical records. Progression of hearing loss was analyzed separately for patients with uni- and bilateral hearing losses. Relative progression of hearing loss was obtained by comparing progression to a reference group. Average progression of PTA was 1.73 dB/yr and was not significantly different in the bilateral and unilateral group. Etiologies that did not show significantly more progression compared with the reference group could be identified as single or short-lasting pathologic events, whereas long-lasting conditions had significant more progression of PTA. Patients with a ski-slope hearing loss that was caused by a single or short-lasting event have low progression rate and are viable for partial insertion to minimize the risk of damaging residual low-frequency hearing. In the absence of such an event, complete insertion should be considered because faster than normal deterioration of low-frequency hearing over time will probably limit the advantage of preservation of residual hearing.

  18. Direct Trocar Insertion with Elevation of the Rectus Sheath in Bariatric Surgery: A Novel Technique.

    Science.gov (United States)

    Habibi, Mani; Seyit, Hakan; Kones, Osman; Kartal, Bahadir; Alis, Halil

    2017-12-30

    Initial trocar entry, the first step in laparoscopic surgery, is associated with several complications. In morbidly obese patients, initial trocar placement is associated with a greater number of complications compared to non-obese patients. Materials and Surgical Technique. In this study, we describe our use of an initial trocar entry technique which is direct trocar insertion with elevation of the rectus sheath by a single Backhaus towel clamp and we would like to evaluate the sa fety and efficacy of its administration in bariatric surgery. Our results indicate that gaining initial trocar entry using our technique leads to successful laparoscopic bariatric surgery. Our technique is a safe, effective, and reliable first step in successful laparoscopic surgery for almost all patients, and is only contraindicated in patients with severe hepatomegaly.

  19. Influence of the Resin Cement Insertion Protocol on the bond Strength of Glass-Fiber Posts

    Directory of Open Access Journals (Sweden)

    João Stein Bassotto

    2017-08-01

    Full Text Available Objective: Evaluate the effect of different techniques for insertion of the resin cement on the bond strength of glass-fiber posts cemented with RelyX U200. Methods: Thirty single-rooted premolars were sectioned at 14 mm from the apex, prepared with ProTaper Universal system and filled by single-cone technique with AH Plus sealer. Root canal filling was partially removed, maintaining 4 mm of gutta-percha at the apical third. Specimens were randomly divided into 3 experimental groups (n=10, according to the strategy used to fiber post cementation, as described: CENTRIX, POST/CEMENT, LENTULO. Exacto N1 glass fiber posts were placed into root canal and cemented with RelyX U200. A cutting machine was used for root’s sectioning providing 3 slices, one for each root third (cervical, medium and apical. Push-out test was performed using a universal testing machine and stereomicroscope was used to analyze the failure mode. Results: CENTRIX (10,05 ± 3,25 Mpa and LENTULO (9,80 ± 3,21 Mpa showed higher means of bond strength values, superior to POST/CEMENT (6,47 ± 3,85 Mpa. Regarding to root third, the cervical third presented the higher bond strength mean (10,62 ± 3,66 Mpa and the apical root third presented the lowest bond strength values (6,58 ± 3,28 Mpa. Conclusion: Bond strength values of glass fiber posts are influenced by the method of insertion of the resin cement RelyX U200. On this sense Centrix and Lentulo systems are recommended.

  20. Safety and Effectiveness of Percutaneously Inserted Peritoneal Ports Compared to Surgically Inserted Ports in a Retrospective Study of 87 Patients with Ovarian Carcinoma over a 10-Year Period

    Energy Technology Data Exchange (ETDEWEB)

    Woodley-Cook, Joel, E-mail: jwoodleycook@gmail.com [The Scarborough Hospital, Vascular and Interventional Radiology, Department of Diagnostic Imaging (Canada); Tarulli, Emidio; Tan, Kong T.; Rajan, Dheeraj K.; Simons, Martin E. [University of Toronto, Vascular and Interventional Radiology, Department of Medical Imaging, University Health Network (Canada)

    2016-11-15

    PurposePlacement of peritoneal ports has become a favorable technique for direct chemotherapy infusion in treating peritoneal metastases from ovarian cancer. We aim to outline an approach to the percutaneous insertion of peritoneal ports and to characterize success and complication rates compared to surgically inserted ports.Materials and MethodsRetrospective analysis was collected from 87 patients who had peritoneal port insertion (28 inserted surgically and 59 percutaneously) for treatment of peritoneal metastases from ovarian cancer from July 2004 to July 2014. Complications were classified according to the SIR Clinical Practice Guidelines as major or minor.ResultsTechnical success rates for surgically and percutaneously inserted ports were 100 and 96.7 %, respectively (p = 0.44), with the two percutaneous failures successful at a later date. There were no major complications in either group. Minor complication rates for surgically versus percutaneously inserted ports were 46.4 versus 22.0 %, respectively (p = 0.02). The infection rate for surgically inserted versus percutaneously inserted ports was 14.3 and 0 %, respectively (p = 0.002). The relative risk of developing a complication from percutaneous peritoneal port insertion without ascites was 3.4 (p = 0.04). For percutaneously inserted ports, the mean in-room procedure time was 81 ± 1.3 min and mean fluoroscopy time was 5.0 ± 4.5 min.ConclusionPercutaneously inserted peritoneal ports are a safe alternative to surgically inserted ports, demonstrating similar technical success and lower complication rates.

  1. Lithium Insertion in LixMn2O4, 0

    DEFF Research Database (Denmark)

    West, Keld; Zachau-Christiansen, Birgit; Skaarup, Steen

    1996-01-01

    of the lithium insertion/extraction reactions is better at the higher voltages (versus Li/Li+), and particularly at the 4 V plateau. The lithium insertion/extraction reaction at the 1 V plateau although essentially reversible is associated with a significant voltage hysteresis.......The electrochemical lithium insertion properties of highly crystalline LixMn2O4 are investigated in the approximate lithium insertion range 0

  2. COST ANALYSIS OF PERIPHERALLY INSERTED CENTRAL CATHETER IN PEDIATRIC PATIENTS.

    Science.gov (United States)

    Dong, Zhaoxin; Connolly, Bairbre L; Ungar, Wendy J; Coyte, Peter C

    2018-01-01

    A peripherally inserted central catheter (PICC) is a useful option in providing secure venous access, which enables patients to be discharged earlier with the provision of home care. The objective was to identify the costs associated with having a PICC from a societal perspective, and to identify factors that are associated with total PICC costs. Data were obtained from a retrospective cohort of 469 hospitalized pediatric patients with PICCs inserted. Both direct and indirect costs were estimated from a societal perspective. Insertion costs, complication costs, nurse and physician assessment costs, inpatient ward costs, catheter removal costs, home care costs, travel costs, and the cost associated with productivity losses incurred by parents were included in this study. Based on catheter dwell time, the median total cost associated with a PICC per patient per day (including inpatient hospital costs) was $3,133.5 ($2,210.7-$9,627.0) in 2017 Canadian dollars ($1.00USD = $1.25CAD in 2017). The adjusted mean cost per patient per day was $2,648.2 ($2,402.4-$2,920.4). Excluding inpatient ward costs, the median total and adjusted costs per patient per day were $198.8 ($91.8-$2,475.8) and $362.7($341.0-$386.0), respectively. Younger age, occurrence of complications, more catheter dwell days, wards with more intensive care, and the absence of home care were significant factors associated with higher total PICC costs. This study has demonstrated the costs associated with PICCs. This information may be helpful for healthcare providers to understand PICC related cost in children and resource implications.

  3. External ear canal cholesteatoma after ventilation tube insertion and mastoidectomy

    Directory of Open Access Journals (Sweden)

    Đerić Dragoslava

    2012-01-01

    Full Text Available Introduction. Etiopathogenetically, there are two types of chollesteatomas: congenital, and acquired. Numerous theories in the literature try to explain the nature of the disease, however, the question about cholesteatomas remain still unanswered. The aim of the study was to present a case of external ear canal cholesteatoma (EEC developed following microsurgery (ventilation tube insertion and mastoidectomy, as well as to point ant possible mechanisms if its development. Case report. A 16-yearold boy presented a 4-month sense of fullness in the ear and otalgia on the left side. A year before, mastoidectomy and posterior atticotomy were performed with ventilation tube placement due to acute purulent mastoiditis. Diagnosis was based on otoscopy examination, audiology and computed tomography (CT findings. CT showed an obliterative soft-tissue mass completely filled the external ear canal with associated erosion of subjacent the bone. There were squamous epithelial links between the canal cholesteatoma and lateral tympanic membrane surface. They originated from the margins of tympanic membrane incision made for a ventilation tube (VT insertion. The position of VT was good as well as the aeration of the middle ear cavity. The tympanic membrane was intact and of normal appearance without middle ear extension or mastoid involvement of cholesteatoma. Cholesteatoma and ventilation tube were both removed. The patient recovered without complications and shortly audiology revealed hearing improving. Follow-up 2 years later, however, showed no signs of the disease. Conclusion. There could be more than one potential delicate mechanism of developing EEC in the ear with VT insertion and mastoidectomy. It is necessary to perform routine otologic surveillance in all patients with tubes. Affected ear CT scan is very helpful in showing the extent of cholesteatoma and bony defects, which could not be assessed by otoscopic examination alone.

  4. Sex-specific aspects of endogenous retroviral insertion and deletion.

    Science.gov (United States)

    Gemmell, Patrick; Hein, Jotun; Katzourakis, Aris

    2013-11-07

    We wish to understand how sex and recombination affect endogenous retroviral insertion and deletion. While theory suggests that the risk of ectopic recombination will limit the accumulation of repetitive DNA in areas of high meiotic recombination, the experimental evidence so far has been inconsistent. Under the assumption of neutrality, we examine the genomes of eighteen species of animal in order to compute the ratio of solo-LTRs that derive from insertions occurring down the male germ line as opposed to the female one (male bias). We also extend the simple idea of comparing autosome to allosome in order to predict the ratio of full-length proviruses we would expect to see under conditions of recombination linked deletion or otherwise. Using our model, we predict the ratio of allosomal to autosomal full-length proviruses to lie between32 and 23 under increasing male bias in mammals and between 1 and 2 under increasing male bias in birds. In contrast to our expectations, we find that a pattern of male bias is not universal across species and that there is a frequent overabundance of full-length proviruses on the allosome beyond the ratios predicted by our model. We use our data as a whole to argue that full-length proviruses should be treated as deleterious mutations or as effectively neutral mutations whose persistence in a full-length state is linked to the rate of meiotic recombination and whose origin is not universally male biased. These conclusions suggest that retroviral insertions on the allosome may be more prolific and that it might be possible to identify mechanisms of replication that are enhanced in the female sex.

  5. Enzymatic functionalization of a nanobody using protein insertion technology.

    Science.gov (United States)

    Crasson, O; Rhazi, N; Jacquin, O; Freichels, A; Jérôme, C; Ruth, N; Galleni, M; Filée, P; Vandevenne, M

    2015-10-01

    Antibody-based products constitute one of the most attractive biological molecules for diagnostic, medical imagery and therapeutic purposes with very few side effects. Their development has become a major priority of biotech and pharmaceutical industries. Recently, a growing number of modified antibody-based products have emerged including fragments, multi-specific and conjugate antibodies. In this study, using protein engineering, we have functionalized the anti-hen egg-white lysozyme (HEWL) camelid VHH antibody fragment (cAb-Lys3), by insertion into a solvent-exposed loop of the Bacillus licheniformis β-lactamase BlaP. We showed that the generated hybrid protein conserved its enzymatic activity while the displayed nanobody retains its ability to inhibit HEWL with a nanomolar affinity range. Then, we successfully implemented the functionalized cAb-Lys3 in enzyme-linked immunosorbent assay, potentiometric biosensor and drug screening assays. The hybrid protein was also expressed on the surface of phage particles and, in this context, was able to interact specifically with HEWL while the β-lactamase activity was used to monitor phage interactions. Finally, using thrombin-cleavage sites surrounding the permissive insertion site in the β-lactamase, we reported an expression system in which the nanobody can be easily separated from its carrier protein. Altogether, our study shows that insertion into the BlaP β-lactamase constitutes a suitable technology to functionalize nanobodies and allows the creation of versatile tools that can be used in innovative biotechnological assays. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  6. Calibration aspects of binaural sound reproduction over insert earphones

    DEFF Research Database (Denmark)

    Hoffmann, Pablo F.; Markovic, Milos; Olesen, Søren Krarup

    2012-01-01

    Earphones are nowadays widely adopted for the reproduction of audio material in mobile multimedia and communication platforms, e.g. smartphones. Reproduction of high-quality spatial sound on such platforms can dramatically improve their applicability, and since two channels are always available...... in earphone-based reproduction, binaural reproduction can be applied directly. This paper is concerned with the theoretical and practical aspects relevant to the correct reproduction of binaural signals over insert earphones. To this purpose, a theoretical model originally developed to explain the acoustic...

  7. The women's insertion in alphabetization program: students motivations

    Directory of Open Access Journals (Sweden)

    Rosângela Pedralli

    2017-12-01

    Full Text Available Is objective of this article motivations in relation to the formal alphabetization process explicit by woman inserted in graphocentric environment. The following question guided the study: What motivates the women participant in this study to call upon a scholastic institution to participate of an alphabetization program?. Theoretically this work, a study case of ethnographic kind, is based on Graff (1994, Britto (2003; 2004, Stromquist (2005, among others. The results point to a convergence between the purposes of these programs and that motivations.

  8. Reverse genetics in Chlamydomonas: a platform for isolating insertional mutants

    Directory of Open Access Journals (Sweden)

    de Montaigu Amaury

    2011-07-01

    Full Text Available Abstract A method was developed to identify insertional mutants of Chlamydomonas reinhardtii disrupted for selected target genes. The approach relies on the generation of thousands of transformants followed by PCR-based screenings that allow for identification of strains harboring the introduced marker gene within specific genes of interest. Our results highlight the strengths and limitations of two independent screens that differed in the nature of the marker DNA used (PCR-amplified fragment containing the plasmid-free marker versus entire linearized plasmid with the marker and in the strategies used to maintain and store transformants.

  9. Pediatric Enteric Feeding Techniques: Insertion, Maintenance, and Management of Problems

    International Nuclear Information System (INIS)

    Nijs, Els L. F.; Cahill, Anne Marie

    2010-01-01

    Enteral feeding is considered a widespread, well-accepted means of delivering nutrition to adults and children who are unable to consume food by mouth or who need support in maintaining adequate nutrition for a variety of reasons, including acute and chronic disease states. Delivery of enteral feeding to nutritionally deprived patients may be achieved by several means. In this article, the indications and insertion of enteral access in children will be reviewed. In addition, common complications and management of problems will be discussed.

  10. Percutaneous insertion of the inferior vena cava filter

    International Nuclear Information System (INIS)

    Huang Lianjun; Jiang Shiliang; Zhao Shihua; Yang Jianguo; Dai Ruping

    2000-01-01

    Objective: To evaluate the effect of inferior vena cava filter for prevention of pulmonary embolus (PE) formation. Methods: Twenty-eight cases of deep venous thrombosis (DVT) were treated with insertion of the inferior vena cava filter. Results: The filter was implanted into inferior vena cava below the rena vein. There were no severe complications occurred in the group. Twenty-seven cases were followed up to 2-34 months, and no migration of the filters were found. And no pulmonary embolism were revealed in fifteen cases without pulmonary thromboembolism. Conclusions: The inferior vena cava filter implantation is a safe and effective method to prevent pulmonary thromboembolism

  11. HB+ prepares for insertion into the CMS solenoid

    CERN Multimedia

    Dave Barney, CERN

    2006-01-01

    With calibration of the first half of the barrel Hadron Calorimeter (HB+) complete (using a radioactive source), preparations begin for its insertion into the solenoid for the Magnet Test and Cosmic Challenge (MTCC). It was moved out of its alcove at the beginning of March - a non-trivial (but completely successful) operation due to the proximity of one of the barrel yoke rings (YB+1). The other half of the barrel Hadron Calorimeter (HB-) and one of the endcaps (HE+) should also be calibrated before the MTCC.

  12. The ATLAS Insertable B-Layer: from construction to operation

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00218666; The ATLAS collaboration

    2016-01-01

    The ATLAS Insertable B-Layer (IBL) is the innermost layer of pixel detectors, and was installed in May 2014 at a radius of 3.3 cm from the beam axis, between the existing Pixel detector and a new smaller radius beam-pipe. The new detector, built to cope with high radiation and occupancy, is the first large scale application of 3D sensors and CMOS 130 nm technology. The IBL detector construction was completed within about two years (2012-2014), and the key features and challenges met during the IBL project are presented, as well as its commissioning and operational experience at the LHC

  13. Systemic Air Embolism Associated with Pleural Pigtail Chest Tube Insertion.

    Science.gov (United States)

    Alkhankan, Emad; Nusair, Ahmad; Mazagri, Rida; Al-Ourani, Mohammed

    2016-01-01

    Pleural pigtail catheter placement is associated with many complications including pneumothorax, hemorrhage, and chest pain. Air embolism is a known but rare complication of pleural pigtail catheter insertion and has a high risk of occurrence with positive pressure ventilation. In this case report, we present a 50-year-old male with bilateral pneumonia who developed a pneumothorax while on mechanical ventilation with continuous positive airway pressure mode. During the placement of the pleural pigtail catheter to correct the pneumothorax, the patient developed a sudden left sided body weakness and became unresponsive. An air embolism was identified in the right main cerebral artery, which was fatal.

  14. Fiber Optic Temperature Sensor Insert for High Temperature Environments

    Science.gov (United States)

    Black, Richard James (Inventor); Costa, Joannes M. (Inventor); Moslehi, Behzad (Inventor); Zarnescu, Livia (Inventor)

    2017-01-01

    A thermal protection system (TPS) test plug has optical fibers with FBGs embedded in the optical fiber arranged in a helix, an axial fiber, and a combination of the two. Optionally, one of the optical fibers is a sapphire FBG for measurement of the highest temperatures in the TPS plug. The test plug may include an ablating surface and a non-ablating surface, with an engagement surface with threads formed, the threads having a groove for placement of the optical fiber. The test plug may also include an optical connector positioned at the non-ablating surface for protection of the optical fiber during insertion and removal.

  15. Inserting Phase Change Lines into Microsoft Excel® Graphs.

    Science.gov (United States)

    Dubuque, Erick M

    2015-10-01

    Microsoft Excel® is a popular graphing tool used by behavior analysts to visually display data. However, this program is not always friendly to the graphing conventions used by behavior analysts. For example, adding phase change lines has typically been a cumbersome process involving the insertion of line objects that do not move when new data is added to a graph. The purpose of this article is to describe a novel way to add phase change lines that move when new data is added and when graphs are resized.

  16. 21 CFR 310.501 - Patient package inserts for oral contraceptives.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Patient package inserts for oral contraceptives... Patient package inserts for oral contraceptives. (a) Requirement for a patient package insert. The safe and effective use of oral contraceptive drug products requires that patients be fully informed of the...

  17. Life Cycle Assessment of Fiber-Reinforced Additive Manufacturing for Injection Molding Insert Production

    DEFF Research Database (Denmark)

    Hofstätter, Thomas; Stotz, Philippe Maurice; Bey, Niki

    2017-01-01

    Additively manufactured (AM) injection molding (IM) inserts have proved to be capable to substitute conventionally manufactured metal inserts with polymer-based insert enforced with short, virgin, unseized carbon fibers (CFs). It has been shown that the implementation of AM technology resulted...

  18. Insertion torque and success of orthodontic mini-implants: A systematic review

    NARCIS (Netherlands)

    Meursinge Reynders, Reint A.; Ronchi, Laura; Ladu, Luisa; van Etten-Jamaludin, Faridi; Bipat, Shandra

    2012-01-01

    Introduction: In this systematic review, we analyzed whether recommended maximum insertion torque values of 5 to 10 Ncm were associated with higher success rates of orthodontic mini-implants compared with mini-implants inserted with maximum insertion torque values beyond this range. Objective

  19. Machine-driven versus manual insertion mode: influence on primary stability of orthodontic mini-implants.

    Science.gov (United States)

    Novsak, Domen; Trinajstic Zrinski, Magda; Spalj, Stjepan

    2015-02-01

    The study aimed to explore the effect of the insertion method on maximal insertion torque as a measure of primary stability while controlling for the effect of cortical bone thickness, mini-implant length and diameter, and vertical insertion force on insertion torque. Six types of mini-implants (Dual Top; Jeil Medical, Corp.) with diameters of 1.4, 1.6, and 2.0 mm and lengths of 6 and 8 mm were inserted manually and in a machine-driven mode into pig rib bone samples, and experiments were repeated 10 times, which totaled 120 tested implants in 120 pig rib samples. Cortical bone thickness was measured with a sliding caliper, whereas insertion torque and vertical insertion forces were recorded with a specially designed device. Significant predictors of better primary stability are thicker cortical bone (explaining 24.2% of variability), wider diameter (20.6%), manual insertion (9.9%), greater length (3.7%), higher maximal vertical insertion force (2.2%), and lower vertical force at maximal insertion torque (1.4%). Manual insertion is associated with higher primary stability of orthodontic mini-implants than mechanical insertion, but thicker cortical bone and larger implant diameter seem to be stronger predictors of primary stability.

  20. Insertion Test of the Inner Vacuum Tank inside the Outer Vacuum Tank

    CERN Multimedia

    B. LEVESY

    2002-01-01

    Photos of the insertion test held on 13th of june 2002. The CMS Magnet inner Vacuum Tank is inserted inside the outer vacuum tank. False thermal shield have been placed on the inner vaccum tank to simulated the coil outer thermal shield. This test is a training for the 2 final insertions.

  1. The insertion of boundaries in world-sheets

    International Nuclear Information System (INIS)

    Green, M.B.; Wai, Paul

    1994-01-01

    This paper considers the operator that inserts a boundary in a string world-sheet on which the string coordinates satisfy either Neumann or constant Dirichlet boundary conditions. With an arbitrary open-string state attached to the boundary, this describes the vertex coupling an open string to a closed string (the ''open-closed string vertex''). A boundary with no open strings attached can be viewed as a vacuum correction to closed-string theory. This factorises into two open-closed string vertices joined together by an open-string propagator. BRST-invariant open-closed string vertices of the Neumann and Dirichlet theories are constructed in a ''light-cone-like'' frame (familiar from some formulations of covariant string field theory) as well as the ''vertex operator'' frame (in which a general open-string state is represented by a vertex operator attached to the world-sheet boundary). The vertices of the Neumann and Dirichlet theories are related to each other by space-time duality.The insertion of a closed Dirichlet boundary may be expressed in the light-cone-like gauge as an interaction vertex that acts at a fixed ''time'' and generates an explicit mass term connecting two arbitrary closed-string states. Some examples of how the presence of such boundaries modifies amplitudes for low-lying states are presented. ((orig.))

  2. Flavonoid insertion into cell walls improves wood properties.

    Science.gov (United States)

    Ermeydan, Mahmut A; Cabane, Etienne; Masic, Admir; Koetz, Joachim; Burgert, Ingo

    2012-11-01

    Wood has an excellent mechanical performance, but wider utilization of this renewable resource as an engineering material is limited by unfavorable properties such as low dimensional stability upon moisture changes and a low durability. However, some wood species are known to produce a wood of higher quality by inserting mainly phenolic substances in the already formed cell walls--a process so-called heartwood formation. In the present study, we used the heartwood formation in black locust (Robinia pseudoacacia) as a source of bioinspiration and transferred principles of the modification in order to improve spruce wood properties (Picea abies) by a chemical treatment with commercially available flavonoids. We were able to effectively insert hydrophobic flavonoids in the cell wall after a tosylation treatment for activation. The chemical treatment reduced the water uptake of the wood cell walls and increased the dimensional stability of the bulk spruce wood. Further analysis of the chemical interaction of the flavonoid with the structural cell wall components revealed the basic principle of this bioinspired modification. Contrary to established modification treatments, which mainly address the hydroxyl groups of the carbohydrates with hydrophilic substances, the hydrophobic flavonoids are effective by a physical bulking in the cell wall most probably stabilized by π-π interactions. A biomimetic transfer of the underlying principle may lead to alternative cell wall modification procedures and improve the performance of wood as an engineering material.

  3. An Adaptive Insertion and Promotion Policy for Partitioned Shared Caches

    Science.gov (United States)

    Mahrom, Norfadila; Liebelt, Michael; Raof, Rafikha Aliana A.; Daud, Shuhaizar; Hafizah Ghazali, Nur

    2018-03-01

    Cache replacement policies in chip multiprocessors (CMP) have been investigated extensively and proven able to enhance shared cache management. However, competition among multiple processors executing different threads that require simultaneous access to a shared memory may cause cache contention and memory coherence problems on the chip. These issues also exist due to some drawbacks of the commonly used Least Recently Used (LRU) policy employed in multiprocessor systems, which are because of the cache lines residing in the cache longer than required. In image processing analysis of for example extra pulmonary tuberculosis (TB), an accurate diagnosis for tissue specimen is required. Therefore, a fast and reliable shared memory management system to execute algorithms for processing vast amount of specimen image is needed. In this paper, the effects of the cache replacement policy in a partitioned shared cache are investigated. The goal is to quantify whether better performance can be achieved by using less complex replacement strategies. This paper proposes a Middle Insertion 2 Positions Promotion (MI2PP) policy to eliminate cache misses that could adversely affect the access patterns and the throughput of the processors in the system. The policy employs a static predefined insertion point, near distance promotion, and the concept of ownership in the eviction policy to effectively improve cache thrashing and to avoid resource stealing among the processors.

  4. End of the EM Barrel Presampler Construction and Insertion

    CERN Multimedia

    Hostachy, J.Y.

    The liquid argon barrel presampler is a thin detector placed in front of the electromagnetic barrel calorimeter, made up of two half barrels also, but with 32 sectors per half barrel instead of 16. Each of these 64 sectors is 3.1 m long, 28 cm large and 2.9 cm thick. Three countries took part in its construction: France (LPSC-Grenoble), Sweden (KTH-Stockholm) and Morocco (Hassan II Ain Chock-Casablanca and Mohamed V-Rabat universities, and CNESTEN-Rabat). The design of the presampler started 11 years ago and the series production began at the end of 2000. Cabling, mechanical and electronic tests of the anodes were achieved in Morocco. Forty-one sectors were assembled and validated at the LPSC-Grenoble and 25 at the KTH-Stockholm. In November 2002, the first half was inserted on the inner face of the first EM calorimeter wheel. The insertion of the other 32 sectors in the second EM calorimeter wheel was achieved in July 2003 (see pictures). The production of two additional sectors will allow us to study the p...

  5. Evaluation of rod insertion issue for NPP Krsko

    International Nuclear Information System (INIS)

    Gunstek, A.; Kurincic, B.

    1998-01-01

    The last couple of years incident with control rods sticking in lower part of the fuel assemblies have been reported of several reactor operators and fuel vendors throughout of the world. Several activities were initiated immediately to determine the root cause of incomplete rod insertion. The purpose of this activities were to collect plants trip history data and testing results, review of available worldwide experience, review of plant operation and fuel management, detailed review of manufacturing and material property and to maintain detailed mechanical model. In this paper, we will present activities in Nuclear Power Plant Krsko which have been performed after NRC initiated the Root Cause Process (NRC Bulletin 96-01). NPP Krsko has not experienced rod insertion anomaly yet but anyway the additional tests were carried out. Rod drop time measurements that were performed normally at beginning of cycle at nominal temperature and pressure (HSB mode) have been extended also to end of cycle. Rod drop time, velocity of dropped rods and magnitudes of the initial recoil bounces vs. burnup were also analyzed. Also RCCA drag test with upper internals in place and drive shafts attached to RCCAs has been performed since then. At last two outages (1997 and 1998) drag test were carried out with digital scale meter to gather additional information. In addition to that, the reload core design has been performed with new constrains on rodded fuel assembly burnup as proposed by the industry.(author)

  6. Lithium insertion into Fe 2(SO 4) 3 frameworks

    Science.gov (United States)

    Manthiram, A.; Goodenough, J. B.

    1989-05-01

    The two polymorphs of Fe 2(SO 4) 3 consist of framework structures built up of tetrahedra sharing corners with octahedra and vice versa. One is rhombohedral, the other is monoclinic. Two moles of lithium insert rapidly into both structures at room temperature. However, lithium insertion into the rhombohedral phase is topotactic without any change of symmetry of the framework, whereas the monoclinic modification is converted to an orthorombic Li 2Fe 2(SO 4) 3 phase via a displacement transition; the existence of a two-phase region between Fe 2(SO 4) 3 and Li 2Fe 2(SO 4) 3 results in a flat OCV of 3.6 V versus lithium, which is 600 mV higher than is found for Li xFFe 2(WO 4) 3 or Li xFe 2(MoO 4) 3. This difference is discussed in terms of the influence of the counter cation on the solid-state Fe {3+}/{2+} redox couple.

  7. Investigation on Composite Throat Insert For Cryogenic Engines

    Science.gov (United States)

    Ayyappan, G.; Tiwari, S. B.; Praveen, RS; Mohankumar, L.; Jathaveda, M.; Ganesh, P.

    2017-02-01

    Injector element testing is an important step in the development and qualification of the cryogenic rocket engines. For the purpose of characterising the injectors, sub scale chambers are used. In order to assess the performance of the injectors, different configurations of the injectors are tested using a combustion chamber and a convergent-divergent nozzle. Pressure distribution along the wall of the chamber and throat insert is obtained from the CFD analysis and temperature distribution is obtained from thermal analysis. Thermo-structural analysis is carried out for the sub-scale model of throat inert using temperature dependent material properties. For the experiments a sub-scale model of the thrust chamber is realised. Injector element tests are carried out for the studies. The objective of the present study is to investigate the behaviour of different throat inserts, mainly graphite, 2-D Carbon-Carbon(2D C-C), 4-D Carbon-Carbon (4D C-C) and Silica Phenolic (SP), under pressure and thermal load for repeated operation of the engine. Analytical results are compared with the test results. The paper gives the results of theoretical studies and experiments conducted with all the four type of throat material. It is concluded that 2D C-C is superior in terms of throat erosion being the least under specified combustion environment.

  8. Immediate versus delayed postpartum insertion of contraceptive implant for contraception.

    Science.gov (United States)

    Sothornwit, Jen; Werawatakul, Yuthapong; Kaewrudee, Srinaree; Lumbiganon, Pisake; Laopaiboon, Malinee

    2017-04-22

    The spacing of pregnancies has a positive impact on maternal and newborn health. The progestin contraceptive implant, which is a long-acting, reversible method of contraception, has a well-established low failure rate that is compatible with tubal sterilization. The standard provision of contraceptive methods on the first postpartum visit may put some women at risk of unintended pregnancy, either due to loss to follow-up or having sexual intercourse prior to receiving contraception. Therefore, the immediate administration of contraception prior to discharge from the hospital that has high efficacy may improve contraceptive prevalence and prevent unintended pregnancy. To compare the initiation rate, effectiveness, and side effects of immediate versus delayed postpartum insertion of implant for contraception. We searched for eligible studies up to 28 October 2016 in the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, and POPLINE. We examined review articles and contacted investigators. We also checked registers of ongoing clinical trials, citation lists of included studies, key textbooks, grey literature, and previous systematic reviews for potentially relevant studies. We sought randomised controlled trials (RCTs) that compared immediate postpartum versus delayed insertion of contraceptive implant for contraception. Two review authors (JS, YW) independently screened titles and abstracts of the search results, and assessed the full-text articles of potentially relevant studies for inclusion. They extracted data from the included studies, assessed risk of bias, compared results, and resolved disagreements by consulting a third review author (PL or SK). We contacted investigators for additional data, where possible. We computed the Mantel-Haenszel risk ratio (RR) with 95% confidence interval (CI) for binary outcomes and the mean difference (MD) with 95% CI for continuous variables. Three studies that included 410 participants met the

  9. [Mid-dermal elastolysis after insertion of a pacemaker].

    Science.gov (United States)

    Kottler, D; Lefèvre, A; Balme, B; Martin-Bourret, V; Zaharia, D; Skowron, F

    2015-11-01

    Mid-dermal elastolysis (MDE) is a rare acquired disease of elastic tissue histologically characterized by focal loss of elastic fibres within the mid-dermis. While the mechanisms leading to MDE remain unknown, increased degradation of elastic fibres may be involved. Many factors potentially triggering such degradation have been suggested. A 58-year-old man consulted for an asymptomatic reticulated eruption that began in the area of a pacemaker implanted six weeks earlier. The eruption consisted of erythematous polycyclic and coalescing macules with a wrinkled centre. Histopathology with orcein staining revealed focal loss of elastic fibres in the superficial reticular dermis only. Hypersensitivity reaction to any components of the pacemaker was ruled out by means of allergy exploration. Laboratory investigations including autoimmunological and haematological factors were unremarkable. A diagnosis was made of a reticular variant of MDE following insertion of a pacemaker. We report the second case of MDE following the insertion of a pacemaker, which could have triggered an inflammatory response directed specifically towards the elastic fibres. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  10. Fracture of crystalline silicon nanopillars during electrochemical lithium insertion

    KAUST Repository

    Lee, S. W.

    2012-02-27

    From surface hardening of steels to doping of semiconductors, atom insertion in solids plays an important role in modifying chemical, physical, and electronic properties of materials for a variety of applications. High densities of atomic insertion in a solid can result in dramatic structural transformations and associated changes in mechanical behavior: This is particularly evident during electrochemical cycling of novel battery electrodes, such as alloying anodes, conversion oxides, and sulfur and oxygen cathodes. Silicon, which undergoes 400% volume expansion when alloying with lithium, is an extreme case and represents an excellent model system for study. Here, we show that fracture locations are highly anisotropic for lithiation of crystalline Si nanopillars and that fracture is strongly correlated with previously discovered anisotropic expansion. Contrary to earlier theoretical models based on diffusion-induced stresses where fracture is predicted to occur in the core of the pillars during lithiation, the observed cracks are present only in the amorphous lithiated shell. We also show that the critical fracture size is between about 240 and 360 nm and that it depends on the electrochemical reaction rate.

  11. Surface heat transfer in a channel with porous insert

    Science.gov (United States)

    Gortyshov, Yu. F.

    1993-05-01

    One of the possible ways of the effective intensification is the realization of heat carrier flows in porous structures. For this purpose inserts are placed in moving heat carrier channels. Despite a large number of publications, net-like, fibrous, brush, caked and powder structures of low and mean porosity (epsilon less than or equal to 0.6) are studied. Application of high-porous permeable honeycomb materials (HPHM) shows, that among the the well-known porous materials possessing maximal permeability (penetrability factors are 10(exp -8) ...10(exp -9) sq m). HPHM's have a characteristic three-dimensional net-like honeycomb structure with high repeatability of cells. All the frame substance is concentrated in stripping ribs, which bound each separate cell. In coolant flowing in the channel with porous insert the transfer of energy from the heated wall into the channel interior originates at the expense of the frame material heat conduction and lateral conduction and lateral convective mixing of flow. In this paper we present the results of analytical and experimental heat transfer investigation at forced heat carrier, flowing in the channel that is filled-in by porous HPHM medium.

  12. Placement peripherally inserted central catheters (PICC): the upper arm approach

    International Nuclear Information System (INIS)

    Choo, In Wook; Choo, Sung Wook; Choi, Dong Il; Yoon, Jung Hwan; Hwang, Jae Woong; Lim, Jae Hoon; Andrews, James C.; Williams, David M.; Cho, Kyung J.

    1995-01-01

    To evaluate a recently developed technique to place a medium-duration (weeks to months) central venous access. Within three-year period, 635 patients were referred to interventional radiology suite for placement of peripherally inserted central catheter (PICC). Contrast medium was injected into the peripheral intravenous line and a puncture was made into the opacified vein near the junction of the middle and upper thirds of the upper arm, either the brachial or basilic vein under fluoroscopic guidance. A 5.5-French peel-away sheath was inserted into the vein and a 5-French silicone catheter was introduced with its distal tip to the junction of the right atrium and superior vena cava. Catheter placement was successful in all patients unless there was a central venous obstruction. Catheters were maintained from 2 days to 5 months with a mean of 3 weeks. Complications included infection requiring removal of the PICC in 16 patients (2.5%), acute thrombosis of the subclavian vein in 3 (0.5%). Occluded catheters in 4 patients were easily cleared with urokinase in place. The PICC system is an excellent option for medium-duration central venous access. Patients were able to carry on normal activities with the catheters in place

  13. Placement peripherally inserted central catheters (PICC): the upper arm approach

    Energy Technology Data Exchange (ETDEWEB)

    Choo, In Wook; Choo, Sung Wook; Choi, Dong Il; Yoon, Jung Hwan; Hwang, Jae Woong; Lim, Jae Hoon [Samsung Medical Center, Seoul (Korea, Republic of); Andrews, James C. [Mayo Clinic, Lansing (United States); Williams, David M.; Cho, Kyung J. [University of Michigan Hospital, Lansing (United States)

    1995-10-15

    To evaluate a recently developed technique to place a medium-duration (weeks to months) central venous access. Within three-year period, 635 patients were referred to interventional radiology suite for placement of peripherally inserted central catheter (PICC). Contrast medium was injected into the peripheral intravenous line and a puncture was made into the opacified vein near the junction of the middle and upper thirds of the upper arm, either the brachial or basilic vein under fluoroscopic guidance. A 5.5-French peel-away sheath was inserted into the vein and a 5-French silicone catheter was introduced with its distal tip to the junction of the right atrium and superior vena cava. Catheter placement was successful in all patients unless there was a central venous obstruction. Catheters were maintained from 2 days to 5 months with a mean of 3 weeks. Complications included infection requiring removal of the PICC in 16 patients (2.5%), acute thrombosis of the subclavian vein in 3 (0.5%). Occluded catheters in 4 patients were easily cleared with urokinase in place. The PICC system is an excellent option for medium-duration central venous access. Patients were able to carry on normal activities with the catheters in place.

  14. Peripherally Inserted Central Catheter dan Pemberian Terapi Intravena pada Neonatus

    Directory of Open Access Journals (Sweden)

    Yani Setiasih

    2017-08-01

    Full Text Available Penelitian sebelumnya menemukan bahwa Peripherally Inserted Central Catheter (PICC efektif dalam pemberian terapi intravena. Belum banyak penelitian yang membandingkan pemberian terapi intravena antara akses intravena yang biasa dilakukan saat ini. Penelitian ini bertujuan membandingkan antara akses intravena perifer dengan Peripherally Inserted Central Catheter (PICC terhadap efektivitas pemberian terapi intravena pada neonatus. Jenis penelitian ini adalah deskriptif komparatif. Dengan teknik purposive sampling, 32 neonatus diikutsertakan sebagai subjek yang terbagi menjadi dua kelompok yaitu kelompok dengan akses intravena perifer dengan PICC. Pada kelompok dengan akses intravena perifer (n=16 dan pada kelompok dengan PICC (n=16. Efektivitas akses intravena dinilai dari kesesuaian terapi intravena yang didapat neonatus dengan kebutuhan yang seharusnya selama 24 jam dalam waktu lima hari menggunakan lembar observasi. Data dianalisis menggunakan uji fisher exact. Hasil penelitian menunjukkan bahwa pemberian terapi intravena menggunakan PICC lebih efektif dibandingkan pemberian terapi intravena menggunakan akses intravena perifer (ρ=0.00. Perawatan neonatus yang membutuhkan terapi intravena di rumah sakit lebih disarankan menggunakan PICC dibandingkan dengan akses intravena perifer.

  15. NURSING CARE IN PATIENTS NEONATES WITH PERIPHERALLY INSERTED CENTRAL CATHETER

    Directory of Open Access Journals (Sweden)

    Anacilda Oliveira Vieira

    2013-05-01

    Full Text Available Introduction:The PICC (peripherally inserted central catheter is a long flexible catheter which isinserted through a peripheral vein, progresses through a needle introducer until the final portion ofthe vena cava, acquiring characteristics of a central catheter.Objective:To point out the maintheoretical and scientific ideas that demonstrate the reliability, competence and ability of nurses toperform the PICC.Methodology:Systematic review of articles, which were found by searching thedatabase scientific journals and bibliographies area.Results:The success of integration depends onthe patient assessment and choice of venous access where the catheter will be positioned, and its tipshould be in the middle third of the superior vena cava, or the middle third of the inferior vena cava.In neonates, which are used more frequently, proper positioning of the catheter is through nursingcare in making the dressing, and the first24 hours it should be compressive. Ideally, the PICCremains in the vein for periods longer than seven days or until the end of treatment, thus decreasinginvasive procedures.Conclusion:According to the Federal Board of Nursing (COFEN, it is lawfulforthe insertion of PICC nurses, provided it has undergone professional training.

  16. Fracture of crystalline silicon nanopillars during electrochemical lithium insertion.

    Science.gov (United States)

    Lee, Seok Woo; McDowell, Matthew T; Berla, Lucas A; Nix, William D; Cui, Yi

    2012-03-13

    From surface hardening of steels to doping of semiconductors, atom insertion in solids plays an important role in modifying chemical, physical, and electronic properties of materials for a variety of applications. High densities of atomic insertion in a solid can result in dramatic structural transformations and associated changes in mechanical behavior: This is particularly evident during electrochemical cycling of novel battery electrodes, such as alloying anodes, conversion oxides, and sulfur and oxygen cathodes. Silicon, which undergoes 400% volume expansion when alloying with lithium, is an extreme case and represents an excellent model system for study. Here, we show that fracture locations are highly anisotropic for lithiation of crystalline Si nanopillars and that fracture is strongly correlated with previously discovered anisotropic expansion. Contrary to earlier theoretical models based on diffusion-induced stresses where fracture is predicted to occur in the core of the pillars during lithiation, the observed cracks are present only in the amorphous lithiated shell. We also show that the critical fracture size is between about 240 and 360 nm and that it depends on the electrochemical reaction rate.

  17. Analysis of the 227 bp short interspersed nuclear element (SINE) insertion of the promoter of the myostatin (MSTN) gene in different horse breeds.

    Science.gov (United States)

    Dall'Olio, Stefania; Scotti, Emilio; Fontanesi, Luca; Tassinari, Marco

    2014-01-01

    The myostatin (MSTN) gene encodes a protein known to be a negative regulator of muscle mass in mammalian species. Different polymorphisms of the horse (Equus caballus) MSTN gene have been identified, including single nucleotide polymorphisms and a short interspersed nuclear element (SINE) insertion of 227 bp within the promoter of the gene. The SINE insertion has been associated with performance traits in Thoroughbred racehorses and it was proposed as a predictor of optimum racing distance. The aims of this study were to perform in silico analysis to identify putative gains or abrogation of transcription-factor binding sites (TFBSs) generated by the SINE allele of the promoter and to analyse the frequency of the SINE insertion in horses used for racing (gallop and trot) and other purposes. The SINE insertion was genotyped in 227 horses from 10 breeds belonging to different morphological types (brachimorphic, mesomorphic, meso-dolichomorphic and dolichomorphic). The presence of the insertion was confirmed in the Quarter Horse (SINE allele frequency of 0.81) and in the Thoroughbred (0.51), whereas the SINE allele did not segregate in any of the other analysed breeds. As the SINE MSTN gene polymorphism may be population or breed specific, it is not a useful marker for association studies in all breeds.

  18. Analysis of the 227 bp short interspersed nuclear element (SINE insertion of the promoter of the myostatin (MSTN gene in different horse breeds

    Directory of Open Access Journals (Sweden)

    Stefania Dall'Olio

    2014-09-01

    Full Text Available The myostatin (MSTN gene encodes a protein known to be a negative regulator of muscle mass in mammalian species. Different polymorphisms of the horse (Equus caballus MSTN gene have been identified, including single nucleotide polymorphisms and a short interspersed nuclear element (SINE insertion of 227 bp within the promoter of the gene. The SINE insertion has been associated with performance traits in Thoroughbred racehorses and it was proposed as a predictor of optimum racing distance. The aims of this study were to perform in silico analysis to identify putative gains or abrogation of transcription-factor binding sites (TFBSs generated by the SINE allele of the promoter and to analyse the frequency of the SINE insertion in horses used for racing (gallop and trot and other purposes. The SINE insertion was genotyped in 227 horses from 10 breeds belonging to different morphological types (brachimorphic, mesomorphic, meso-dolichomorphic and dolichomorphic. The presence of the insertion was confirmed in the Quarter Horse (SINE allele frequency of 0.81 and in the Thoroughbred (0.51, whereas the SINE allele did not segregate in any of the other analysed breeds. As the SINE MSTN gene polymorphism may be population or breed specific, it is not a useful marker for association studies in all breeds.

  19. Prevalence and risk factors of inadequate cervical dilation following laminaria insertion in second-trimester abortion--case control study.

    Science.gov (United States)

    Ben-Ami, Ido; Stern, Sharon; Vaknin, Zvi; Smorgick, Noam; Schneider, David; Halperin, Reuvit

    2015-04-01

    The objective was to explore the prevalence of and risk factors for inadequate cervical dilation following insertion of a single set of laminaria in women scheduled for dilation & evacuation (D&E) at 14-24 weeks' gestation. We retrospectively reviewed all cases of women who underwent pregnancy termination by D&E at 14-24 weeks' gestation between January 2003 and December 2013. All cases in which the surgical procedure was cancelled due to failure to achieve adequate cervical dilation after a single set of laminaria inadequate cervical dilation were included. The control group was women who underwent D&E following adequate cervical dilation after a single set of laminaria, and were matched according to gestational week in a ratio of 1:3. The overall dilation failure rate was 3.2%, with 4.0% among the induced-abortion patients and 1.5% among the patients with fetal demise (p=.002). Patients who had inadequate cervical dilation had lower rates of gravidity (p=.002) and previous spontaneous vaginal delivery (plaminaria insertion, namely, previous cesarean section (p=.002) and previous cervical procedure (plaminaria. Women who are scheduled for D&E, and in whom one of these risk factors exists, might benefit from additional interventions to achieve better cervical preparation. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. PET performance evaluation of MADPET4: a small animal PET insert for a 7 T MRI scanner

    Science.gov (United States)

    Omidvari, Negar; Cabello, Jorge; Topping, Geoffrey; Schneider, Florian R.; Paul, Stephan; Schwaiger, Markus; Ziegler, Sibylle I.

    2017-11-01

    MADPET4 is the first small animal PET insert with two layers of individually read out crystals in combination with silicon photomultiplier technology. It has a novel detector arrangement, in which all crystals face the center of field of view transaxially. In this work, the PET performance of MADPET4 was evaluated and compared to other preclinical PET scanners using the NEMA NU 4 measurements, followed by imaging a mouse-size hot-rod resolution phantom and two in vivo simultaneous PET/MRI scans in a 7 T MRI scanner. The insert had a peak sensitivity of 0.49%, using an energy threshold of 350 keV. A uniform transaxial resolution was obtained up to 15 mm radial offset from the axial center, using filtered back-projection with single-slice rebinning. The measured average radial and tangential resolutions (FWHM) were 1.38 mm and 1.39 mm, respectively. The 1.2 mm rods were separable in the hot-rod phantom using an iterative image reconstruction algorithm. The scatter fraction was 7.3% and peak noise equivalent count rate was 15.5 kcps at 65.1 MBq of activity. The FDG uptake in a mouse heart and brain were visible in the two in vivo simultaneous PET/MRI scans without applying image corrections. In conclusion, the insert demonstrated a good overall performance and can be used for small animal multi-modal research applications.

  1. Research on the Influence of Orthopaedic Inserts on Pressure Distribution in the Foot

    Directory of Open Access Journals (Sweden)

    Ignas Rutulys

    2011-02-01

    Full Text Available The article examines the influence of individual orthopaedic inserts on pressure distribution in the foot. Feet deformations, types of orthopaedic inserts, materials and pressure in the foot testing methods are discussed. Experimental computer measurements of pressure in the foot before and after the use of inserts have been done. During research, the inserts made of different kinds of materials selected according to human weight, pathology, skin sensitivity and many other reasons has been used. It has been determinated that orthopaedic inserts have a more noticeable impact on children whose feet is adjusted easier if compared with those of adults.Article in Lithuanian

  2. The study on diamond-coated insert by DC plasma jet CVD

    International Nuclear Information System (INIS)

    Zhou Kesong; Dai Mingjiang; Song Jinbing; Kuang Tongchun; Liu Zhengyi

    2001-01-01

    Diamond coating were deposited on cemented carbide inserts by DC plasma jet CVD. The cemented carbide inserts were pretreated by methods including chemical etching of Co, Ar/H 2 plasma etching. The characteristics of diamond film, interface structure, adhesion strength and film stress were analysized by different methods such as SEM, XRD, Raman spectrum etc. A comparing experiment of cutting Al - 22 % Si alloy was carried out with diamond-coated cemented carbide inserts and uncoated cemented carbide inserts. The results show that the diamond-coated cemented carbide insert has a great advantage for cutting abrasive high content Al - Si alloy. (author)

  3. The purB gene controls rhizosphere colonization by Pantoea agglomerans.

    Science.gov (United States)

    Chauhan, P S; Nautiyal, C S

    2010-02-01

    To isolate the rhizosphere competence-defective transposon Tn5 mutant of Pantoea agglomerans NBRISRM (SRM) and to identify the gene causing defect in its root colonization ability. From over 5000 clones containing Tn5, one mutant P. agglomerans NBRISRMT (SRMT) showing 6 log units less colonization when compared with SRM, after 30 days in sand-nonsterilized soil assay system was selected for further work to determine the effects of the mutation on rhizosphere competence. Southern hybridization analysis of restricted genomic DNA of SRMT demonstrated that the mutant had a single Tn5 insert. SRM increased in titre to about 2 x 10(8) CFU g(-1) root, compared with the indigenous bacterial population of heterotrophs of about 5 x 10(7) CFU g(-1) root. In contrast, 30 days later, the titre value of SRMT was almost undetectable at 1 x 10(2) CFU g(-1) root, demonstrating its inability to survive and colonize the rhizosphere. Sequencing of the flanking region of the Tn5 mutant revealed that Tn5 disrupted the purB gene. A defect in the colonization phenotype of the SRMT was attributed to the disruption in adenylosuccinate lyase (EC 4.3.2.2) which is encoded by the pur B gene and is required for rhizosphere colonization in P. agglomerans. Significantly less exopolysaccharide and biofilm was formed by SRMT when compared to SRM, because of the disruption of the purB gene. This work provides the first evidence for a functional role of purB gene in rhizosphere competence and root colonization by any rhizobacteria.

  4. Twisting method for reducing friction during insertion of a sheath introducer and a sheathless guiding catheter.

    Science.gov (United States)

    Takagawa, Yoshitoki; Furukawa, Tetsuaki

    2018-01-01

    A sheathless system that inserts a catheter directly into the artery can reduce puncture site-related complications through a 2-Fr reduction of the outer diameter. However, the gap between the dilator and the guiding catheter of the sheathless system is larger than the gap between the dilator and sheath of the introducer system, resulting in stronger insertion resistance. A twisting method with rapid alternating rotation of a device to the left and right during insertion can reduce the insertion resistance. This method can be effective with the sheathless system which has a larger gap. To examine the effect of size reduction on the sheathless system and the effect of insertion resistance reduction using the twisting method, we developed an insertion simulator and compared insertion resistance to a 5-Fr sheath introducer and a 5-Fr sheathless system, with and without the twisting method. The insertion simulator pushed a sheath introducer or a sheathless system toward a mock artery consisted with a 5-mm urethane and a 1-mm rubber sheet by an electrical motor with or without twisting motion generated by a crank shaft. Insertion resistance during the penetration was measured by a tension meter. The insertion resistance was less with the 5-Fr sheathless system than with the 5-Fr sheath introducer. The resistance reduced further with use of twisting for both the sheathed and sheathless catheters. In conclusion, the experiment suggests the benefits of twisting insertion of a sheathless guiding catheter for reduction of puncture site-related complications.

  5. Comparison of Three Methods for Laryngeal Mask Airway Insertion in Adults: Standard, Lateral and Rotational

    Directory of Open Access Journals (Sweden)

    Ata Mahmoodpoor

    2014-03-01

    Full Text Available Determination of an optimal Laryngeal Mask Airway (LMA insertion technique is of great importance as unsuccessful prolonged insertion and multiple attempts are associated with adverse respiratory effects and trauma. The purpose of this study was to compare the ease of insertion of LMA using the standard approach with lateral and rotational techniques. 150 adult patients undergoing general anesthesia using LMA were randomized into one of the three mentioned techniques: standard, rotational and lateral. The time for LMA insertion, number of LMA insertion attempts and LMA insertion success rate were noted for all patients. Demographic characteristic of patients between three groups did not have significant difference. Patients irritation and time for LMA insertion was significantly less in lateral technique (P

  6. Mono-allelic retrotransposon insertion addresses epigenetic transcriptional repression in human genome.

    Science.gov (United States)

    Byun, Hyang-Min; Heo, Kyu; Mitchell, Kasey J; Yang, Allen S

    2012-02-02

    Retrotransposons have been extensively studied in plants and animals and have been shown to have an impact on human genome dynamics and evolution. Their ability to move within genomes gives retrotransposons to affect genome instability. we examined the polymorphic inserted AluYa5, evolutionary young Alu, in the progesterone receptor gene to determine the effects of Alu insertion on molecular environment. We used mono-allelic inserted cell lines which carry both Alu-present and Alu-absent alleles. To determine the epigenetic change and gene expression, we performed restriction enzyme digestion, Pyrosequencing, and Chromatin Immunoprecipitation. We observed that the polymorphic insertion of evolutionally young Alu causes increasing levels of DNA methylation in the surrounding genomic area and generates inactive histone tail modifications. Consequently the Alu insertion deleteriously inactivates the neighboring gene expression. The mono-allelic Alu insertion cell line clearly showed that polymorphic inserted repetitive elements cause the inactivation of neighboring gene expression, bringing aberrant epigenetic changes.

  7. Tn7 and Tn501 Insertions into Pseudomonas aeruginosa plasmid R91-5: mapping of two transfer regions.

    OpenAIRE

    Moore, R J; Krishnapillai, V

    1982-01-01

    We constructed a restriction endonuclease map of the Pseudomonas aeruginosa narrow-host-range plasmid R91-5. Insertions of transposons Tn7 and Tn501 into the plasmid DNA were characterized physically and genetically. The distribution of sites of insertion showed some regional specificity for the insertion of these transposons, especially TN501. The insertion of Tn7 was unusual in that all 42 of 43 insertions were in the same orientation. By relating phenotypic changes to the site of insertion...

  8. Evaluation of PET performance and MR compatibility of a preclinical PET/MR insert with digital silicon photomultiplier technology

    Energy Technology Data Exchange (ETDEWEB)

    Hallen, Patrick; Schug, David; Wehner, Jakob [Department of Physics of Molecular Imaging Systems, RWTH Aachen University (Germany); Weissler, Bjorn [Department of Chemical Application Research, Philips Research (Germany); Gebhardt, Pierre [Division of Imaging Sciences and Biomedical Engineering, King’s College London (United Kingdom); Goldschmidt, Benjamin [Department of Physics of Molecular Imaging Systems, RWTH Aachen University (Germany); Salomon, Andre [Department of Oncology Solutions, Philips Research (Germany); Duppenbecker, Peter [Department of Physics of Molecular Imaging Systems, RWTH Aachen University (Germany); Kiessling, Fabian [Institute for Experimental Molecular Imaging, RWTH Aachen University (Germany); Schultz, Volkmar [Department of Physics of Molecular Imaging Systems, RWTH Aachen University (Germany)

    2015-05-18

    In this work we present detailed characterizations of our preclinical high resolution PET/MR insert based on the Hyperion-IID platform. The PET/MR insert consists of a ring of 10 singles detection modules, each comprising 2x3 scintillation detector stacks. Each detector stack features a 30x30 pixelated LYSO crystal array with a height of 12 mm and a pitch of 1 mm, coupled via a slit 2 mm light guide to a digital SiPM tile. The PET performance is stable under a wide range of operating points. The spatial resolution is below 1Ä,mm and the CRT reaches 260 or 450 ps depending on trigger settings. The energy resolution is 12.6% FWHM. The characterization of the MR compatibility showed no relevant degradation in PET performance during MRI operation. On the MRI side, we observe a degradation in B0 homogeneity from a VRMS of 0.03 ppm to 0.08 ppm with active shimming, while observing only minor degradations in the B0 field. The noise floor is slightly increased by 2-15% without any observable dependence on the activity. The Z gradients induces an observable eddy current inside the PET inserts which can lead to ghosting artifacts for EPI sequences. However, we don't observe any visible image degradation for widely used anatomical imaging sequences such as gradient echo and turbo spin echo sequences. To prove the viability of our PET/MR insert for in vivo small animal studies, we successfully performed a longitudinal mouse study with subcutaneously injected tumor model cells. The simultaneously acquired PET/MR images provide a high level of anatomical information and soft tissue contrast in the MR layer together with a high resolution image of the FDG tracer distribution in the PET layer.

  9. Biogenesis of the mitochondrial TOM complex: Mim1 promotes insertion and assembly of signal-anchored receptors.

    Science.gov (United States)

    Becker, Thomas; Pfannschmidt, Sylvia; Guiard, Bernard; Stojanovski, Diana; Milenkovic, Dusanka; Kutik, Stephan; Pfanner, Nikolaus; Meisinger, Chris; Wiedemann, Nils

    2008-01-04

    The translocase of the outer membrane (TOM complex) is the central entry gate for nuclear-encoded mitochondrial precursor proteins. All Tom proteins are also encoded by nuclear genes and synthesized as precursors in the cytosol. The channel-forming beta-barrel protein Tom40 is targeted to mitochondria via Tom receptors and inserted into the outer membrane by the sorting and assembly machinery (SAM complex). A further outer membrane protein, Mim1, plays a less defined role in assembly of Tom40 into the TOM complex. The three receptors Tom20, Tom22, and Tom70 are anchored in the outer membrane by a single transmembrane alpha-helix, located at the N terminus in the case of Tom20 and Tom70 (signal-anchored) or in the C-terminal portion in the case of Tom22 (tail-anchored). Insertion of the precursor of Tom22 into the outer membrane requires pre-existing Tom receptors while the import pathway of the precursors of Tom20 and Tom70 is only poorly understood. We report that Mim1 is required for efficient membrane insertion and assembly of Tom20 and Tom70, but not Tom22. We show that Mim1 associates with SAM(core) components to a large SAM complex, explaining its role in late steps of the assembly pathway of Tom40. We conclude that Mim1 is not only required for biogenesis of the beta-barrel protein Tom40 but also for membrane insertion and assembly of signal-anchored Tom receptors. Thus, Mim1 plays an important role in the efficient assembly of the mitochondrial TOM complex.

  10. Immediate vs. delayed insertion of intrauterine contraception after second trimester abortion: study protocol for a randomized controlled trial

    Science.gov (United States)

    2011-01-01

    Background We describe the rationale and protocol for a randomized controlled trial (RCT) to assess whether intrauterine contraception placed immediately after a second trimester abortion will result in fewer pregnancies than current recommended practice of intended placement at 4 weeks post-abortion. Decision analysis suggests the novel strategy could substantially reduce subsequent unintended pregnancies and abortions. This paper highlights considerations of design, implementation and evaluation of a trial expected to provide rigorous evidence for appropriate insertion timing and health economics of intrauterine contraception after second trimester abortion. Methods/Design Consenting women choosing to use intrauterine contraception after abortion for a pregnancy of 12 to 24 weeks will be randomized to insertion timing groups either immediately (experimental intervention) or four weeks (recommended care) post abortion. Primary outcome measure is pregnancy rate at one year. Secondary outcomes include: cumulative pregnancy rates over five year follow-up period, comprehensive health economic analyses comparing immediate and delayed insertion groups, and device retention rates, complication rates (infection, expulsion) and, contraceptive method satisfaction. Web-based Contraception Satisfaction Questionnaires, clinical records and British Columbia linked health databases will be used to assess primary and secondary outcomes. Enrolment at all clinics in the province performing second trimester abortions began in May 2010 and is expected to complete in late 2011. Data on one year outcomes will be available for analysis in 2014. Discussion The RCT design combined with access to clinical records at all provincial abortion clinics, and to information in provincial single-payer linked administrative health databases, birth registry and hospital records, offers a unique opportunity to evaluate such an approach by determining pregnancy rate at one through five years among

  11. Identification of novel genes in the carotenogenic and oleaginous yeast Rhodotorula toruloides through genome-wide insertional mutagenesis.

    Science.gov (United States)

    Liu, Yanbin; Koh, Chong Mei John; Yap, Sihui Amy; Du, Minge; Hlaing, Mya Myintzu; Ji, Lianghui

    2018-02-21

    Rhodotorula toruloides is an outstanding producer of lipids and carotenoids. Currently, information on the key metabolic pathways and their molecular basis of regulation remains scarce, severely limiting efforts to engineer it as an industrial host. We have adapted Agrobacterium tumefaciens-mediated transformation (ATMT) as a gene-tagging tool for the identification of novel genes in R. toruloides. Multiple factors affecting transformation efficiency in several species in the Pucciniomycotina subphylum were optimized. The Agrobacterium transfer DNA (T-DNA) showed predominantly single-copy chromosomal integrations in R. toruloides, which were trackable by high efficiency thermal asymmetric interlaced PCR (hiTAIL-PCR). To demonstrate the application of random T-DNA insertions for strain improvement and gene hunting, 3 T-DNA insertional libraries were screened against cerulenin, nile red and tetrazolium violet respectively, resulting in the identification of 22 mutants with obvious phenotypes in fatty acid or lipid metabolism. Similarly, 5 carotenoid biosynthetic mutants were obtained through visual screening of the transformants. To further validate the gene tagging strategy, one of the carotenoid production mutants, RAM5, was analyzed in detail. The mutant had a T-DNA inserted at the putative phytoene desaturase gene CAR1. Deletion of CAR1 by homologous recombination led to a phenotype similar to RAM5 and it could be genetically complemented by re-introduction of the wild-type CAR1 genome sequence. T-DNA insertional mutagenesis is an efficient forward genetic tool for gene discovery in R. toruloides and related oleaginous yeast species. It is also valuable for metabolic engineering in these hosts. Further analysis of the 27 mutants identified in this study should augment our knowledge of the lipid and carotenoid biosynthesis, which may be exploited for oil and isoprenoid metabolic engineering.

  12. Immediate vs. delayed insertion of intrauterine contraception after second trimester abortion: study protocol for a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Soon Judith A

    2011-06-01

    Full Text Available Abstract Background We describe the rationale and protocol for a randomized controlled trial (RCT to assess whether intrauterine contraception placed immediately after a second trimester abortion will result in fewer pregnancies than current recommended practice of intended placement at 4 weeks post-abortion. Decision analysis suggests the novel strategy could substantially reduce subsequent unintended pregnancies and abortions. This paper highlights considerations of design, implementation and evaluation of a trial expected to provide rigorous evidence for appropriate insertion timing and health economics of intrauterine contraception after second trimester abortion. Methods/Design Consenting women choosing to use intrauterine contraception after abortion for a pregnancy of 12 to 24 weeks will be randomized to insertion timing groups either immediately (experimental intervention or four weeks (recommended care post abortion. Primary outcome measure is pregnancy rate at one year. Secondary outcomes include: cumulative pregnancy rates over five year follow-up period, comprehensive health economic analyses comparing immediate and delayed insertion groups, and device retention rates, complication rates (infection, expulsion and, contraceptive method satisfaction. Web-based Contraception Satisfaction Questionnaires, clinical records and British Columbia linked health databases will be used to assess primary and secondary outcomes. Enrolment at all clinics in the province performing second trimester abortions began in May 2010 and is expected to complete in late 2011. Data on one year outcomes will be available for analysis in 2014. Discussion The RCT design combined with access to clinical records at all provincial abortion clinics, and to information in provincial single-payer linked administrative health databases, birth registry and hospital records, offers a unique opportunity to evaluate such an approach by determining pregnancy rate at one

  13. Machinability and scratch wear resistance of carbon-coated WC inserts

    Energy Technology Data Exchange (ETDEWEB)

    Pazhanivel, B., E-mail: palcecri@yahoo.co.in; Kumar, T. Prem; Sozhan, G.

    2015-03-15

    Highlights: • Cemented WC inserts were coated with carbon by CVD. • The deposits were either loosely held MWCNTs or adherent carbides. • Co-efficient of friction (ramp load; 1–13 N); 0.2 and 0.1 μ, respectively, for the uncoated and carbide-coated inserts. • The carbide-coated insert exhibited better machinability and surface finish than a commercial TiCN-coated insert. - Abstract: In this work, cemented tungsten carbide (WC) inserts were coated with nanocarbons/carbides by chemical vapor deposition (CVD) and their machinability and scratch wear resistance were investigated. The hardness and surface conditions of the WC substrate were studied before and after coating. The CVD-generated nanocarbons on the insert surfaces were examined by SEM, FE-SEM and TEM. The electron microscopic images revealed that the carbons generated were multi-walled carbon nanotubes (MWCNTs) or carbides depending on the experimental conditions. In both the cases, the cutting edges of the inserts had dense deposits. Scratch wear test with the coated inserts showed that the co-efficient of friction was 0.1 μ as against 0.2 μ for the uncoated inserts under a ramp load of 1–13 N. The machinability characteristics of commercially available TiCN-coated inserts and the carbon-coated WC inserts were compared by using a CNC machine and a Rapid I vision inspection system. It was found that the carbide-coated inserts exhibited machinability with better surface finish comparable to that of the TiCN-coated inserts while the MWCNT-coated inserts showed inferior adhesion properties.

  14. Pre-puncture ultrasound guided epidural insertion before vaginal delivery.

    Science.gov (United States)

    Nassar, Mahmoud; Abdelazim, Ibrahim A

    2015-10-01

    Palpation method is widely used in clinical practice to identify the puncture site during combined spinal-epidural (CSE) blocks. Tuffier's line, is an anatomical landmark between two iliac crests (inter-cristal), which is widely used to identify the puncture site during CSE blocks is not always an indicator for specific vertebral level or inter-vertebral space. One hundred and Ten (110) women were scheduled for normal vaginal delivery and were randomized into two equal groups; palpation group and an ultrasound guided group to detect the efficacy of puncture ultrasound before CSE blocks to increase chances of successful CSE procedure on the first attempt and to reduce the number of attempts or punctures during insertion of CSE catheter. There were no significant differences between two studied groups regarding; maternal age, weight and height, while, there was a significant difference between two studied groups regarding; parity. Percentage of successful CSE procedure on the first attempt was significantly higher (67.27%) in ultrasound compared to palpation group (40%). Number of punctures (attempts) were significantly less in ultrasound (1.2 ± 0.6) compared to palpation group (2.3 ± 0.8) and the number of redirections was also significantly less in ultrasound (1.4 ± 0.5) compared to palpation group (2.8 ± 1.6). Although, time to identify puncture site was significantly longer in ultrasound compared to palpation group and total procedure time was longer in ultrasound (9.1 ± 1.5 min) compared to palpation group (6.2 ± 1.2 min), there was no significant difference between two studied groups regarding; time to identify puncture site and total procedure time. Two cases of dural puncture in palpation versus no cases in ultrasound group and two cases of intravascular catheter placement (one in each group), with no significant difference between two groups. Pre- puncture ultrasound guided epidural insertion before vaginal delivery, increases the chance of a

  15. De Novo Insertions and Deletions of Predominantly Paternal Origin Are Associated with Autism Spectrum Disorder

    Directory of Open Access Journals (Sweden)

    Shan Dong

    2014-10-01

    Full Text Available Summary: Whole-exome sequencing (WES studies have demonstrated the contribution of de novo loss-of-function single-nucleotide variants (SNVs to autism spectrum disorder (ASD. However, challenges in the reliable detection of de novo insertions and deletions (indels have limited inclusion of these variants in prior analyses. By applying a robust indel detection method to WES data from 787 ASD families (2,963 individuals, we demonstrate that de novo frameshift indels contribute to ASD risk (OR = 1.6; 95% CI = 1.0–2.7; p = 0.03, are more common in female probands (p = 0.02, are enriched among genes encoding FMRP targets (p = 6 × 10−9, and arise predominantly on the paternal chromosome (p < 0.001. On the basis of mutation rates in probands versus unaffected siblings, we conclude that de novo frameshift indels contribute to risk in approximately 3% of individuals with ASD. Finally, by observing clustering of mutations in unrelated probands, we uncover two ASD-associated genes: KMT2E (MLL5, a chromatin regulator, and RIMS1, a regulator of synaptic vesicle release. : Insertions and deletions (indels have proven especially difficult to detect in exome sequencing data. Dong et al. now identify indels in exome data for 787 autism spectrum disorder (ASD families. They demonstrate association between de novo indels that alter the reading frame and ASD. Furthermore, by observing clustering of indels in unrelated probands, they uncover two additional ASD-associated genes: KMT2E (MLL5, a chromatin regulator, and RIMS1, a regulator of synaptic vesicle release.

  16. Wicking: a rapid method for manually inserting ion channels into planar lipid bilayers.

    Science.gov (United States)

    Costa, Justin A; Nguyen, Dac A; Leal-Pinto, Edgar; Gordon, Ronald E; Hanss, Basil

    2013-01-01

    The planar lipid bilayer technique has a distinguished history in electrophysiology but is arguably the most technically difficult and time-consuming method in the field. Behind this is a lack of experimental consistency between laboratories, the challenges associated with painting unilamellar bilayers, and the reconstitution of ion channels into them. While there has be a trend towards automation of this technique, there remain many instances where manual bilayer formation and subsequent membrane protein insertion is both required and advantageous. We have developed a comprehensive method, which we have termed "wicking", that greatly simplifies many experimental aspects of the lipid bilayer system. Wicking allows one to manually insert ion channels into planar lipid bilayers in a matter of seconds, without the use of a magnetic stir bar or the addition of other chemicals to monitor or promote the fusion of proteoliposomes. We used the wicking method in conjunction with a standard membrane capacitance test and a simple method of proteoliposome preparation that generates a heterogeneous mixture of vesicle sizes. To determine the robustness of this technique, we selected two ion channels that have been well characterized in the literature: CLIC1 and α-hemolysin. When reconstituted using the wicking technique, CLIC1 showed biophysical characteristics congruent with published reports from other groups; and α-hemolysin demonstrated Type A and B events when threading single stranded DNA through the pore. We conclude that the wicking method gives the investigator a high degree of control over many aspects of the lipid bilayer system, while greatly reducing the time required for channel reconstitution.

  17. Wicking: a rapid method for manually inserting ion channels into planar lipid bilayers.

    Directory of Open Access Journals (Sweden)

    Justin A Costa

    Full Text Available The planar lipid bilayer technique has a distinguished history in electrophysiology but is arguably the most technically difficult and time-consuming method in the field. Behind this is a lack of experimental consistency between laboratories, the challenges associated with painting unilamellar bilayers, and the reconstitution of ion channels into them. While there has be a trend towards automation of this technique, there remain many instances where manual bilayer formation and subsequent membrane protein insertion is both required and advantageous. We have developed a comprehensive method, which we have termed "wicking", that greatly simplifies many experimental aspects of the lipid bilayer system. Wicking allows one to manually insert ion channels into planar lipid bilayers in a matter of seconds, without the use of a magnetic stir bar or the addition of other chemicals to monitor or promote the fusion of proteoliposomes. We used the wicking method in conjunction with a standard membrane capacitance test and a simple method of proteoliposome preparation that generates a heterogeneous mixture of vesicle sizes. To determine the robustness of this technique, we selected two ion channels that have been well characterized in the literature: CLIC1 and α-hemolysin. When reconstituted using the wicking technique, CLIC1 showed biophysical characteristics congruent with published reports from other groups; and α-hemolysin demonstrated Type A and B events when threading single stranded DNA through the pore. We conclude that the wicking method gives the investigator a high degree of control over many aspects of the lipid bilayer system, while greatly reducing the time required for channel reconstitution.

  18. Comparison of complications between pediatric peripherally inserted central catheter placement techniques

    International Nuclear Information System (INIS)

    Dasgupta, Niloy; Lungren, Matthew P.; Patel, Manish N.; Racadio, John M.; Johnson, Neil D.

    2016-01-01

    Peripherally inserted central catheter (PICC) is among the most common procedures performed in children in the hospital setting. PICC insertion can be simplified with the use of a sheathed needle as an alternative to the modified Seldinger technique. To retrospectively evaluate PICC placement for the technique used and the incidence of complications at a large pediatric tertiary care center. We retrospectively reviewed all PICC placements at a single institution over a 4-year period. We reviewed patient records for demographic data, PICC placement technique, catheter size and number of lumens, and the incidence of complications (i.e. multiple attempted puncture sites, phlebitis and vessel thrombosis). We analyzed complication rates between two placement techniques using a chi-square test. We identified 8,816 successful PICC placements, 4,749 (53.9%) in males and 4,067 (46.1%) in females. The average age of the patients for which a line was placed was 5.6 years (range 1 day to 45 years). A direct sheathed needle puncture technique was used in 8,362 (94.9%) placements and a modified Seldinger technique was used in 454 (5.1%). Complications occurred in 312 (3.7%) of direct sheathed needle puncture placements versus 17 (3.7%) of modified Seldinger placements (P = 0.99). Multiple puncture sites were required in 175 (2.1%) attempted direct sheathed needle puncture placements compared with 8 (1.7%) attempted modified Seldinger placements (P = 0.63). Phlebitis occurred in 94 (1.1%) direct sheathed needle puncture lines versus 5 (1.1%) modified Seldinger placed lines (P = 0.96). Vessel thrombosis occurred in 43 (0.5%) direct sheathed needle puncture lines versus 4 (0.9%) modified Seldinger placed lines (P = 0.30). The direct peel-away sheathed needle vessel puncture technique and the modified Seldinger technique used to place PICC lines in children have similar complication rates. (orig.)

  19. Comparison of complications between pediatric peripherally inserted central catheter placement techniques

    Energy Technology Data Exchange (ETDEWEB)

    Dasgupta, Niloy; Lungren, Matthew P. [Lucile Packard Children' s Hospital Stanford, Department of Radiology, Palo Alto, CA (United States); Patel, Manish N.; Racadio, John M.; Johnson, Neil D. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States)

    2016-09-15

    Peripherally inserted central catheter (PICC) is among the most common procedures performed in children in the hospital setting. PICC insertion can be simplified with the use of a sheathed needle as an alternative to the modified Seldinger technique. To retrospectively evaluate PICC placement for the technique used and the incidence of complications at a large pediatric tertiary care center. We retrospectively reviewed all PICC placements at a single institution over a 4-year period. We reviewed patient records for demographic data, PICC placement technique, catheter size and number of lumens, and the incidence of complications (i.e. multiple attempted puncture sites, phlebitis and vessel thrombosis). We analyzed complication rates between two placement techniques using a chi-square test. We identified 8,816 successful PICC placements, 4,749 (53.9%) in males and 4,067 (46.1%) in females. The average age of the patients for which a line was placed was 5.6 years (range 1 day to 45 years). A direct sheathed needle puncture technique was used in 8,362 (94.9%) placements and a modified Seldinger technique was used in 454 (5.1%). Complications occurred in 312 (3.7%) of direct sheathed needle puncture placements versus 17 (3.7%) of modified Seldinger placements (P = 0.99). Multiple puncture sites were required in 175 (2.1%) attempted direct sheathed needle puncture placements compared with 8 (1.7%) attempted modified Seldinger placements (P = 0.63). Phlebitis occurred in 94 (1.1%) direct sheathed needle puncture lines versus 5 (1.1%) modified Seldinger placed lines (P = 0.96). Vessel thrombosis occurred in 43 (0.5%) direct sheathed needle puncture lines versus 4 (0.9%) modified Seldinger placed lines (P = 0.30). The direct peel-away sheathed needle vessel puncture technique and the modified Seldinger technique used to place PICC lines in children have similar complication rates. (orig.)

  20. Overview of the ATLAS Insertable B-Layer (IBL) Project

    CERN Document Server

    Kagan, M; The ATLAS collaboration

    2013-01-01

    The upgrades for the ATLAS Pixel Detector will be staged in preparation for high luminosity LHC. The first upgrade for the Pixel Detector will be the construction of a new pixel layer which is currently under construction and will be installed during the first shutdown of the LHC machine, in 2013-14. The new detector, called the Insertable B-layer (IBL), will be installed between the existing Pixel Detector and a new, smaller radius beam-pipe at a radius of 3.3 cm. The IBL required the development of several new technologies to cope with increased radiation and pixel occupancy and also to improve the physics performance through reduction of the pixel size and a more stringent material budget. Two different silicon sensor technologies, planar n-in-n and 3D, will be used, connected with the new generation 130nm IBM CMOS FE-I4 readout chip via solder bump-bonds. 32 \

  1. The microstructure and micromechanics of the tendon-bone insertion

    Science.gov (United States)

    Rossetti, L.; Kuntz, L. A.; Kunold, E.; Schock, J.; Müller, K. W.; Grabmayr, H.; Stolberg-Stolberg, J.; Pfeiffer, F.; Sieber, S. A.; Burgkart, R.; Bausch, A. R.

    2017-06-01

    The exceptional mechanical properties of the load-bearing connection of tendon to bone rely on an intricate interplay of its biomolecular composition, microstructure and micromechanics. Here we identify that the Achilles tendon-bone insertion is characterized by an interface region of ~500 μm with a distinct fibre organization and biomolecular composition. Within this region, we identify a heterogeneous mechanical response by micromechanical testing coupled with multiscale confocal microscopy. This leads to localized strains that can be larger than the remotely applied strain. The subset of fibres that sustain the majority of loading in the interface area changes with the angle of force application. Proteomic analysis detects enrichment of 22 proteins in the interfacial region that are predominantly involved in cartilage and skeletal development as well as proteoglycan metabolism. The presented mechanisms mark a guideline for further biomimetic strategies to rationally design hard-soft interfaces.

  2. Clinical relevance of distal biceps insertional and footprint anatomy.

    Science.gov (United States)

    van den Bekerom, Michel P J; Kodde, Izaäk F; Aster, Asir; Bleys, Ronald L A W; Eygendaal, Denise

    2016-07-01

    The aim of this review was to present an overview, based on a literature search, of surgical anatomy for distal biceps tendon repairs, based on the current literature. A narrative review was performed using Pubmed/Medline using key words: Search terms were distal biceps, insertional, and anatomy. Last decade, the interest in both reconstruction techniques, as well as surgical anatomy of the distal biceps tendon, has increased. The insights into various aspects of distal biceps tendon anatomy (two tendons, bicipital tuberosity, lacertus fibrosis, bicipital-radial bursa, posterior interosseous nerve, and lateral antebrachial cutaneous nerve) have evolved significantly in the last years. Thorough knowledge of the anatomy is essential for the surgeon in order to understand the biomechanics of rupture and reconstruction of the distal biceps tendon and to avoid injuries of the nerves. Some tips and tricks are provided, and some pitfalls were described to avoid complications and optimize surgical outcome. IV.

  3. Prototype of Superconducting Quadrupole for ISR Low-Beta Insertion

    CERN Multimedia

    CERN PhotoLab

    1977-01-01

    In colliders, smaller beam cross-section means higher luminosity. Beam-size being proportional to the square-root of the "beta function" value, a small beta means small beam size, hence high luminosity. The first p-p collision in the ISR occurred in January 1971 and in 1973 a study was launched on low-beta insertions, which focus beams to even smaller sizes at the beam crossing points. In 1976 the first prototype of a superconducting quadrupole was tested. Here we see Theodor Tortschanoff with a prototype of 1.25 m magnetic length. Manufacture of 8 quadrupoles (4 of L=1.15 m, 4 of L=0.65 m) began at Alsthom in 1978. They were installed at point 8 of the ISR, enhancing luminosity there until final low-beta operation in December 1983. For details see "Yellow Report" CERN 76-16.

  4. A training system for ultrasound-guided needle insertion procedures.

    Science.gov (United States)

    Zhu, Yanong; Magee, Derek; Ratnalingam, Rish; Kessel, David

    2007-01-01

    Needle placement into a patient body under guidance of ultrasound is a frequently performed procedure in clinical practice. Safe and successful performance of such procedure requires a high level of spatial reasoning and hand-eye co-ordination skills, which must be developed through intensive practice. In this paper we present a training system designed to improve the skills of interventional radiology trainees in ultrasound-guided needle placement procedures. Key issues involved in the system include surface and volumetric registration, solid texture modelling, spatial calibration, and real-time synthesis and rendering of ultrasound images. Moreover, soft tissue deformation caused by the needle movement and needle cutting is realised using a mass-spring-model approach. These have led to a realistic ultrasound simulation system, which has been shown to be a useful tool for the training of needle insertion procedures. Preliminary results of a construct evaluation study indicate the effectiveness and usefulness of the developed training system.

  5. Overview of the ATLAS Insertable B-Layer (IBL) Project

    CERN Document Server

    Djama, F; The ATLAS collaboration

    2012-01-01

    The upgrades for the ATLAS Pixel Detector will be staged in preparation for high luminosity LHC. The first upgrade for the Pixel Detector will be the construction of a new pixel layer which will be installed during the first shutdown of the LHC machine, foreseen in 2013-14. The new detector, called the Insertable B-layer (IBL), will be installed between the existing Pixel Detector and a new, smaller radius beampipe at a radius of 3.3 cm. The IBL will require the development of several new technologies to cope with increased radiation and pixel occupancy and also to improve the physics performance through reduction of the pixel size and a more stringent material budget. Two different and promising silicon sensor technologies, planar n-in-n and 3D, are currently under investigation for the IBL. An overview of the IBL project, of the module design and qualification with particular emphasis on irradiation tests will be presented.

  6. Radiation regression patterns after cobalt plaque insertion for retinoblastoma

    International Nuclear Information System (INIS)

    Buys, R.J.; Abramson, D.H.; Ellsworth, R.M.; Haik, B.

    1983-01-01

    An analysis of 31 eyes of 30 patients who had been treated with cobalt plaques for retinoblastoma disclosed that a type I radiation regression pattern developed in 15 patients; type II, in one patient, and type III, in five patients. Nine patients had a regression pattern characterized by complete destruction of the tumor, the surrounding choroid, and all of the vessels in the area into which the plaque was inserted. This resulting white scar, corresponding to the sclerae only, was classified as a type IV radiation regression pattern. There was no evidence of tumor recurrence in patients with type IV regression patterns, with an average follow-up of 6.5 years, after receiving cobalt plaque therapy. Twenty-nine of these 30 patients had been unsuccessfully treated with at least one other modality (ie, light coagulation, cryotherapy, external beam radiation, or chemotherapy)

  7. Radiation regression patterns after cobalt plaque insertion for retinoblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Buys, R.J.; Abramson, D.H.; Ellsworth, R.M.; Haik, B.

    1983-08-01

    An analysis of 31 eyes of 30 patients who had been treated with cobalt plaques for retinoblastoma disclosed that a type I radiation regression pattern developed in 15 patients; type II, in one patient, and type III, in five patients. Nine patients had a regression pattern characterized by complete destruction of the tumor, the surrounding choroid, and all of the vessels in the area into which the plaque was inserted. This resulting white scar, corresponding to the sclerae only, was classified as a type IV radiation regression pattern. There was no evidence of tumor recurrence in patients with type IV regression patterns, with an average follow-up of 6.5 years, after receiving cobalt plaque therapy. Twenty-nine of these 30 patients had been unsuccessfully treated with at least one other modality (ie, light coagulation, cryotherapy, external beam radiation, or chemotherapy).

  8. Hardening of cutting tool inserts by ion implantation

    International Nuclear Information System (INIS)

    Zlobin, V.N.; Bannikov, M.G.; Draper, P.H.; Zotov, A.V.

    2001-01-01

    Surface hardening has long been recognized as an important method of increasing the integrity and life of cutting tools. In this work we report preliminary investigations of hardening of conventional hard metal tools by ion implantation Three types of mixed carbide tool inserts were treated by bombardment with 40kV ions of Al, Ti, Zr or W in an ambient of Ar or N/sub 2/, with doses of up to 13*10/sup 17/ ions/cm/sup 2/. The samples were monitored by micro-hardness measurements. Complex behaviors as a function of the implantation dose/time have been observed, and are commented on in terms of the lattice disruption caused by the bombardment. Hardness increments of up to 22 % have been obtained using an ion implanter of industrial size, and cutting tests have shown an improvement, by a factor of three, in the life of these treated tools. (author)

  9. Tray-Grid Guide for Accurate Mini-implant Insertion

    Directory of Open Access Journals (Sweden)

    Madhukar Reddy Rachala

    2012-01-01

    Full Text Available The use of Orthodontic mini-implant anchorage is rapidly growing. With the improved understanding of the biomechanics, an array of tooth movements are possible with mini-implants. Precise positioning of miniscrews is critical to their success. Surgical stents, guides and templates can transfer a radiographically planned, three-dimensional implant position to the surgical site more accurately. A new technique using thermoplastic sheets and a grid made of 0.012" stainless steel ligature wire (Tray-Grid Guide; TGG was devised that provides reliable guidance in terms of both location and angulations with minimal complications. It was found to be effective and efficient to obtain a precise and accurate placement of mini-implants. It is particularly valuable when the mini-implant is prescribed and inserted by different clinicians or when the orthodontist is inexperienced in implant techniques.

  10. Insert earphone calibration for hear-through options

    DEFF Research Database (Denmark)

    Hoffmann, Pablo F.; Christensen, Flemming; Hammershøi, Dorte

    2013-01-01

    A hear-through option in earphones exists when the earphone has a microphone mounted on the outside of the earphone thus allowing the user to hear the surroundings - or not. Although routing the microphone signal to the earphone driver is relatively straightforward, the physical presence of the e......A hear-through option in earphones exists when the earphone has a microphone mounted on the outside of the earphone thus allowing the user to hear the surroundings - or not. Although routing the microphone signal to the earphone driver is relatively straightforward, the physical presence...... of the earphone will modify the natural acoustics of the external ear, and some form of compensation is required to make the microphone-earphone combination acoustically transparent. Here we derive a general expression for the design target response of insert earphones with hear-through options emphasizing...

  11. Interchromosomal insertions. Identification of five cases and a review.

    Science.gov (United States)

    Van Hemel, J O; Eussen, H J

    2000-11-01

    In five families with questionable chromosome rearrangements, we identified an interchromosomal insertion by fluorescent in situ hybridization (FISH). In case 1 with a dir ins (5;11)(p14;q14q24) in three generations, the mentally retarded and microcephalic proband showed a 5p14-->pter deletion. In case 2, a duplication (13)(q21.31--> q31.2) combined with a deletion (11)(q14-->q22) segregated from a reciprocal ins(11;13)(q14q122)(q21.32q31.2), causing a mixed phenotype with psychomotor retardation, caput quadratum, choanal atresia, and pes equinovarus. In case 3, a dir ins (18;5)(q21.3;p13.1p14) was associated with spontaneous abortions, in case 4, the proband with mental retardation, microcephaly, and a heart defect showed a pure trisomy of (12)(q13-->q15), which had segregated from a carrier of an ins (18;12)(p11.3;q13q15). In case 5, a duplication of (10)(q26.3-->q25.2) segregated from an inv ins(5;10)(q15;q26.3q25.2), which was passed on directly from a mother to her son,with mental retardation. In all families the elucidation of the insertional translocation (IT) considerably increased the associated genetic risks of carriers. For the review, we collected data from 81 articles on 87 IT probands on ascertainment, origin, familial transmittance, progeny, and genetic risks of IT carriers. We also discussed the recombinant chromosomes and complex rearrangements associated with ITs, and listed chromosome regions occurring solely as deletions, or solely as duplications, or as both to facilitate genotype/phenotype correlations. We conclude that ITs are rare chromosomal rearrangements with an 1:80,000 incidence, of which nearly 80% were referred because of congenital abnormalities and mental retardation. A maternal origin was seen in 59.5%, a paternal origin in 26.6%, and 13.9% were de novo. No notable difference in fertility between male and female IT carriers was noticed. Bias of ascertainment was excluded in 15 familial cases and led to an estimate of the genetic

  12. Effectiveness of one-piece implants inserted in cuspid sites.

    Science.gov (United States)

    Carinci, Francesco

    2012-12-01

    One-piece implants (OPIs) incorporate the trans-mucosal abutment facing the soft tissues as an integral part of the implant. OPIs are usually welded together and loaded immediately. Since no report focuses specifically on OPIs inserted in cuspid sites, a retrospective study is performed. Nineteen patients (10 females and 9 males) with a median age of 62 years (range, 43-80) were admitted at the Dental Clinic, University of Chieti (Italy), for evaluation and implant treatment, by one surgeon between January and December 2010. In our series, the survival rate (SVR) and success rate (SCR) were 96.8% and 100%, respectively. Statistical analysis demonstrated that no studied variable had an impact on the survival (i.e., lost implants) and clinical success (i.e., crestal bone resorption). OPIs are reliable devices for oral rehabilitation in the cuspid sites.

  13. Alu polymorphic insertions reveal genetic structure of north Indian populations.

    Science.gov (United States)

    Tripathi, Manorama; Tripathi, Piyush; Chauhan, Ugam Kumari; Herrera, Rene J; Agrawal, Suraksha

    2008-10-01

    The Indian subcontinent is characterized by the ancestral and cultural diversity of its people. Genetic input from several unique source populations and from the unique social architecture provided by the caste system has shaped the current genetic landscape of India. In the present study 200 individuals each from three upper-caste and four middle-caste Hindu groups and from two Muslim populations in North India were examined for 10 polymorphic Alu insertions (PAIs). The investigated PAIs exhibit high levels of polymorphism and average heterozygosity. Limited interpopulation variance and genetic flow in the present study suggest admixture. The results of this study demonstrate that, contrary to common belief, the caste system has not provided an impermeable barrier to genetic exchange among Indian groups.

  14. Atomic compressibility and reversible insertion of atoms into solids

    International Nuclear Information System (INIS)

    Connerade, J.P.; Semaoune, R.

    2000-01-01

    We developed a theoretical model to investigate the compressibility of atoms. Atoms are confined inside a spherical cavity, simulated numerically by a finite repulsive potential barrier. The energy levels and wavefunctions of confined atoms are determined by solving, for different cavity radii, the relativistic Dirac-Fock equations, including formally the repulsive barrier. The changes in the atomic size and in the ground-state energy level allow one to define a positive isotropic pressure exerted on the confined atom. The model is applied to atomic caesium and it is demonstrated quantitatively that the remarkable compressibility of caesium originates from a purely atomic mechanism, namely the pressure-induced collapse of the 5d orbital. We propose that this mechanism can also drive, at an atomic level, a reversible insertion of atoms into solids. Applications to lithium-ion batteries are briefly discussed at the end of this paper. (author)

  15. Cutting insert and work piece materials for minimum quantity lubrication

    Science.gov (United States)

    Kurgin, Sheri; Barber, Gary; Zou, Qian

    2011-05-01

    There is considerable interest in utilizing either dry or minimum quantity lubrication (MQL) as an alternative to flood cooling due to environmental concerns with flood coolant such as excessive misting and disposal of the used coolant. Dry machining can result in high tool wear and also built up edge problems on the cutting tool. The objective of this research was to study the effect of work piece material and tool material on the machining characteristics, in this case reaming, of aluminum using MQL. In particular, a high tin casting and three different tool materials: carbide, DLC and PCD were studied. The high tin casting was found to produce lower cutting temperature and lower spindle power. The PCD coated insert performed the best in terms of lowest temperature rise, lowest spindle power and highest part quality.

  16. Analysis of reactivity insertion accidents in PWR reactors

    International Nuclear Information System (INIS)

    Camargo, C.T.M.

    1978-06-01

    A calculation model to analyze reactivity insertion accidents in a PWR reactor was developed. To analyze the nuclear power transient, the AIREK-III code was used, which simulates the conventional point-kinetic equations with six groups of delayed neutron precursors. Some modifications were made to generalize and to adapt the program to solve the proposed problems. A transient thermal analysis model was developed which simulates the heat transfer process in a cross section of a UO 2 fuel rod with Zircalloy clad, a gap fullfilled with Helium gas and the correspondent coolant channel, using as input the nulcear power transient calculated by AIREK-III. The behavior of ANGRA-i reactor was analized during two types of accidents: - uncontrolled rod withdrawal from subcritical condition; - uncontrolled rod withdrawal at power. The results and conclusions obtained will be used in the license process of the Unit 1 of the Central Nuclear Almirante Alvaro Alberto. (Author) [pt

  17. [Bowel injuries after port insertion in laparoscopy. Gynerisq's database analysis].

    Science.gov (United States)

    Cesario, E; Crochet, P; Boyer de Latour, F-X; Eglin, G; De Rochambeau, B; Agostini, A

    2016-11-01

    Port insertion is a high-risk period during laparoscopy. The French Gynecologist and Obstetricians College (CNGOF) published recommendations in 2010 to minimize those risks. The aim of our analysis was to establish the accidents' circumstances and consequences and to determine if those incidents could have been depending on whether recommendations had been respected or not. Gynerisq is an approved organism by the Haute Autorité de santé (HAS). Its mission is to evaluate and improve practices by a risk management centered approach. We analysed incidents reported by Gynerisq's adherents in an experience report database. Above 114 incidents analysed in the Gynerisq's database, we reported 31 bowel injuries. Those injuries occurred for 77.4% (24/31) during planned interventions. For 32.3% of the cases (10/31), interventions were judged complex by the surgeons. A total of 54.8% (17/31) of the patients had a history of laparotomy. Above 27 injuries occurred during Veress needle or open laparoscopy, 17 could have been avoided regarding to the surgeon. The causes reported were in 10 cases that the recommendations had not been respected, in 2 cases another cause and in 5 cases no causes were given to explain the incident. Our analysis shows that bowel injuries after port insertion, in open laparoscopy or Veress needle use, do not seem to occur only in an emergency context or during complicated interventions. However, most of the incidents occurred for patients with risk factors. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  18. Heat transfer behaviors in round tube with conical ring inserts

    International Nuclear Information System (INIS)

    Promvonge, P.

    2008-01-01

    To increase convection heat transfer in a uniform heat flux tube by a passive method, several conical rings used as turbulators are mounted over the test tube. The effects of the conical ring turbulator inserts on the heat transfer rate and friction factor are experimentally investigated in the present work. Conical rings with three different diameter ratios of the ring to tube diameter (d/D = 0.5, 0.6, 0.7) are introduced in the tests, and for each ratio, the rings are placed with three different arrangements (converging conical ring, referred to as CR array, diverging conical ring, DR array and converging-diverging conical ring, CDR array). In the experiment, cold air at ambient condition for Reynolds numbers in a range of 6000-26,000 is passed through the uniform heat flux circular tube. It is found that the ring to tube diameter ratio and the ring arrays provide a significant effect on the thermal performance of the test tube. The experimental results demonstrate that the use of conical ring inserts leads to a higher heat transfer rate than that of the plain surface tube, and the DR array yields a better heat transfer than the others. The results are also correlated in the form of Nusselt number as a function of Reynolds number, Prandtl number and diameter ratio. An augmentation of up to 197%, 333%, and 237% in Nusselt number is obtained in the turbulent flow for the CR, DR and CDR arrays, respectively, although the effect of using the conical ring causes a substantial increase in friction factor

  19. Facile construction of a random protein domain insertion library using an engineered transposon.

    Science.gov (United States)

    Shah, Vandan; Pierre, Brennal; Kim, Jin Ryoun

    2013-01-15

    Insertional fusion between multiple protein domains represents a novel means of creating integrated functionalities. Currently, there is no robust guideline for selection of insertion sites ensuring the desired functional outcome of insertional fusion. Therefore, construction and testing of random domain insertion libraries, in which a host protein domain is randomly inserted into a guest protein domain, significantly benefit extensive exploration of sequence spaces for insertion sites. Short peptide residues are usually introduced between protein domains to alleviate structural conflicts, and the interdomain linker residues may affect the functional outcome of protein insertion complexes. Unfortunately, optimal control of interdomain linker residues is not always available in conventional methods used to construct random domain insertion libraries. Moreover, most conventional methods employ blunt-end rather than sticky-end ligation between host and guest DNA fragments, thus lowering library construction efficiency. Here, we report the facile construction of random domain insertion libraries using an engineered transposon. We show that random domain insertion with optimal control of interdomain linker residues was possible with our engineered transposon-based method. In addition, our method employs sticky-end rather than blunt-end ligation between host and guest DNA fragments, thus allowing for facile construction of relatively large sized libraries. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. Insertion forces and intracochlear trauma in temporal bone specimens implanted with a straight atraumatic electrode array.

    Science.gov (United States)

    Mirsalehi, Marjan; Rau, Thomas S; Harbach, Lenka; Hügl, Silke; Mohebbi, Saleh; Lenarz, Thomas; Majdani, Omid

    2017-05-01

    The aim of the study was to evaluate insertion forces during manual insertion of a straight atraumatic electrode in human temporal bones, and post-implantation histologic evaluation of the samples to determine whether violation of intracochlear structures is related to insertion forces. In order to minimize intracochlear trauma and preserve residual hearing during cochlear implantation, knowledge of the insertion forces is necessary. Ten fresh frozen human temporal bones were prepared with canal wall down mastoidectomy. All samples were mounted on a one-axis force sensor. Insertion of a 16-mm straight atraumatic electrode was performed from different angles to induce "traumatic" insertion. Histologic evaluation was performed in order to evaluate intracochlear trauma. In 4 of 10 samples, dislocation of the electrode into scala vestibuli was observed. The mean insertion force for all 10 procedures was 0.003 ± 0.005 N. Insertion forces measured around the site of dislocation to scala vestibuli in 3 of 4 samples were significantly higher than insertion forces at the same location of the cochleae measured in samples without trauma (p straight atraumatic electrode is lower than reported by other studies using longer electrodes. Based on our study, insertion forces leading to basilar membrane trauma may be lower than the previously reported direct rupture forces.

  1. IUD in first-trimester abortion: immediate intrauterine contraceptive devices insertion vs delayed insertion following the next menstruation bleeding.

    Science.gov (United States)

    Tsikouras, Panagiotis; Vrachnis, Nikolaos; Grapsa, Anastasia; Tsagias, Nikolaos; Pinidis, Petros; Liberis, Anastasios; Ammari, Alexandros; Grapsas, Xenofon; Galazios, Georgios; Liberis, Vasileios

    2014-07-01

    Approximately 21 days after an abortion, ovulation occurs in 50 % of women. Installation of an IUD directly after induced or spontaneous abortion offers immediate contraceptive protection. The purpose of the present study was to weigh up contraceptive safety and adverse reactions of IUD inserted directly after first-trimester abortion under general or paracervical anesthesia as against the fitting of IUD in the days of the next menstrual cycle without anesthesia. During the period May 1987 to October 2010, 73 women (Group A) underwent an immediate post-abortion insertion IUD after a first-trimester spontaneous or induced abortion under general or local paracervical anesthesia and 69 participants (Group B) received IUD during the next menstrual cycle without anesthesia. Questionnaires were completed by all the women of the study with respect to the effects of IUD. The women were examined every 3 months for 1 year after the fitting of the IUD in the out-patient department of the University Obstetrics Gynecological Department of Alexandroupolis, Democritus University of Thrace, Greece. The demographic characteristics of the women of the two groups were similar. The age of the women ranged between 19 and 44 years, while 61.98 % were women with one or two children and 38.02 % were women with three or more children. During the first menstrual cycles, with the exception of vaginal hemorrhages (5 %) and adnexitis (1 %), no serious adverse reactions were noted. During the transvaginal ultrasonography checks in both groups, no observation was made of any dislocation of the IUD, except for two cases in the subgroup of those women with paracervical anesthesia and one case in the women of Group B. As concerns the questionnaire with regard to the women's subjective evaluation of IUD, satisfactory answers were given. There were no differences between the two groups either with respect to the security of the supplied contraceptive methods or to the development of side effects.

  2. Transition-metal-catalyzed enantioselective heteroatom-hydrogen bond insertion reactions.

    Science.gov (United States)

    Zhu, Shou-Fei; Zhou, Qi-Lin

    2012-08-21

    Carbon-heteroatom bonds (C-X) are ubiquitous and are among the most reactive components of organic compounds. Therefore investigations of the construction of C-X bonds are fundamental and vibrant fields in organic chemistry. Transition-metal-catalyzed heteroatom-hydrogen bond (X-H) insertions via a metal carbene or carbenoid intermediate represent one of the most efficient approaches to form C-X bonds. Because of the availability of substrates, neutral and mild reaction conditions, and high reactivity of these transformations, researchers have widely applied transition-metal-catalyzed X-H insertions in organic synthesis. Researchers have developed a variety of rhodium-catalyzed asymmetric C-H insertion reactions with high to excellent enantioselectivities for a wide range of substrates. However, at the time that we launched our research, very few highly enantioselective X-H insertions had been documented primarily because of a lack of efficient chiral catalysts and indistinct insertion mechanisms. In this Account, we describe our recent studies of copper- and iron-catalyzed asymmetric X-H insertion reactions by using chiral spiro-bisoxazoline and diimine ligands. The copper complexes of chiral spiro-bisoxazoline ligands proved to be highly enantioselective catalysts for N-H insertions of α-diazoesters into anilines, O-H insertions of α-diazoesters into phenols and water, O-H insertions of α-diazophosphonates into alcohols, and S-H insertions of α-diazoesters into mercaptans. The iron complexes of chiral spiro-bisoxazoline ligands afforded the O-H insertion of α-diazoesters into alcohols and water with unprecedented enantioselectivities. The copper complexes of chiral spiro-diimine ligands exhibited excellent reactivity and enantioselectivity in the Si-H insertion of α-diazoacetates into a wide range of silanes. These transition-metal-catalyzed X-H insertions have many potential applications in organic synthesis because the insertion products, including chiral

  3. The Hairless Stem Phenotype of Cotton (Gossypium barbadense) Is Linked to a Copia-Like Retrotransposon Insertion in a Homeodomain-Leucine Zipper Gene (HD1).

    Science.gov (United States)

    Ding, Mingquan; Ye, Wuwei; Lin, Lifeng; He, Shae; Du, Xiongming; Chen, Aiqun; Cao, Yuefen; Qin, Yuan; Yang, Fen; Jiang, Yurong; Zhang, Hua; Wang, Xiyin; Paterson, Andrew H; Rong, Junkang

    2015-09-01

    Cotton (Gossypium) stem trichomes are mostly single cells that arise from stem epidermal cells. In this study, a homeodomain-leucine zipper gene (HD1) was found to cosegregate with the dominant trichome locus previously designated as T1 and mapped to chromosome 6. Characterization of HD1 orthologs revealed that the absence of stem trichomes in modern Gossypium barbadense varieties is linked to a large retrotransposon insertion in the ninth exon, 2565 bp downstream from the initial codon in the At subgenome HD1 gene (At-GbHD1). In both the At and Dt subgenomes, reduced transcription of GbHD1 genes is caused by this insertion. The disruption of At-HD1 further affects the expression of downstream GbMYB25 and GbHOX3 genes. Analyses of primitive cultivated accessions identified another retrotransposon insertion event in the sixth exon of At-GbHD1 that might predate the previously identified retrotransposon in modern varieties. Although both retrotransposon insertions results in similar phenotypic changes, the timing of these two retrotransposon insertion events fits well with our current understanding of the history of cotton speciation and dispersal. Taken together, the results of genetics mapping, gene expression and association analyses suggest that GbHD1 is an important component that controls stem trichome development and is a promising candidate gene for the T1 locus. The interspecific phenotypic difference in stem trichome traits also may be attributable to HD1 inactivation associated with retrotransposon insertion. Copyright © 2015 by the Genetics Society of America.

  4. A comparative study of three methods of ProSeal laryngeal mask airway insertion in children with simulated difficult laryngoscopy using a rigid neck collar.

    Science.gov (United States)

    Das, Bikramjit; Mitra, Subhro; Samanta, Arijit; Samal, Rajiv Kumar

    2014-09-01

    Combined introducer tool and stylet technique of ProSeal laryngeal mask airway (PLMA) insertion was compared with the conventional digital manipulation and introducer tool technique in children with a rigid neck collar. This was a randomized, single blinded, prospective study. Ninety ASA Grade I-II children weighing 10-20 kg were randomly allocated for PLMA insertion using the digital, introducer tool (IT) or combined IT and stylet techniques. Each group contained 30 patients. Difficult laryngoscopy was simulated using a rigid neck collar. The laryngoscopic view was graded prior to PLMA insertion. The digital and IT techniques were performed according to the manufacturer's instructions. The combined technique involved attaching the IT to the PLMA and inserting a flexible stylet through the drain tube. The median Cormack and Lehane grade was 2 in all three groups. Insertion was more frequently successful with the combined technique at the first attempt (combined 100%, digital 65.38%, IT 66.67%; p  0.05). The time taken for successful placement was similar among groups at the first attempt, but was shorter for the combined technique for overall attempts (combined 18.33 ± 1.27 seconds, digital 27.85 ± 9.05 seconds, IT 26.89 ± 7.17 seconds; p airway morbidity. PLMA insertion with combined IT and stylet technique was more frequently successful than the digital or IT technique in pediatric patients without cervical spine motion. Copyright © 2014. Published by Elsevier B.V.

  5. Nelaton catheter assisted versus standard nasogastric tube insertion: a randomized, clinical trial.

    Science.gov (United States)

    Ghaemi, M; Mousavinasab, N; Jalili, S

    2014-01-09

    It is sometimes difficult to insert a nasogastric tube in an anaesthetized patient. We evaluated the benefit of reinforcing the distal portion of the nasogastric tube with a Nelaton catheter: 8 and 10 French Nelaton catheters were inserted into 16 and 18 French nasogastric tubes respectively through the first proximal holes of tubes up to their tips. The patients anaesthetized were randomly allocated into either the control or the Nelaton groups, and nasogastric tube was inserted as deeply as the catheter length, then the catheter was withdrawn and the tube was inserted farther to reach the stomach. Eighty patients (40 in each group) were included in this study. The success rate of nasogastric tube insertion was 90% in the Nelaton group and 57% in the control group (P = 0.001). The mean insertion time was 80 (SD 43) and 92 (SD 35) seconds in the Nelaton and the control groups respectively.

  6. Structural and biophysical analysis of sequence insertions in the Venezuelan Equine Encephalitis Virus macro domain.

    Science.gov (United States)

    Guillén, Jaime; Lichière, Julie; Rabah, Nadia; Beitzel, Brett F; Canard, Bruno; Coutard, Bruno

    2015-04-02

    Random transposon insertions in viral genomes can be used to reveal genomic regions important for virus replication. We used these genomic data to evaluate at the protein level the effect of such insertions on the Venezuelan Equine Encephalitis Virus nsP3 macro domain. The structural analysis showed that transposon insertions occur mainly in loops connecting the secondary structure elements. Some of the insertions leading to a temperature sensitive viral phenotype (ts) are close to the cleavage site between nsP2 and nsP3 or the ADP-ribose binding site, two important functions of the macro domain. Using four mutants mimicking the transposon insertions, we confirmed that these insertions can affect the macro domain properties without disrupting the overall structure of the protein. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. A new method for insertion of long intestinal tube for small bowel obstruction

    OpenAIRE

    Sekiba, Kazuma; Ohmae, Tomoya; Odawara, Nariaki; Moriyama, Makoto; Kanai, Sachiko; Tsuboi, Mayo; Saito, Tomotaka; Uchino, Koji; Akamatsu, Masatoshi; Okamoto, Makoto

    2016-01-01

    Abstract It is often difficult to insert a long intestinal tube (LT) in patients with small bowel obstruction (SBO). We developed a novel technique for inserting an LT without endoscopy called nonendoscopic over-the-wire method via short nasogastric tube (NEWSt). We evaluated the efficacy and safety of NEWSt. We performed a retrospective study of patients who underwent LT insertion for SBO without any indications of strangulation with either NEWSt (n?=?16) or endoscopy (n?=?17) between Novemb...

  8. Efficacy and safety of peripherally inserted central venous catheters in acute cardiac care management.

    Science.gov (United States)

    Poletti, Fabrizio; Coccino, Claudio; Monolo, Davide; Crespi, Paolo; Ciccioli, Giorgio; Cordio, Giuseppe; Seveso, Giovanni; De Servi, Stefano

    2018-03-01

    Patients admitted to cardiac intensive care unit need administration of drugs intravenously often in concomitance of therapeutic techniques such as non-invasive ventilation, continuous renal replacement therapy and intra-aortic balloon counterpulsation. Therefore, the insertion of central venous catheters provides a reliable access for delivering medications, laboratory testing and hemodynamic monitoring, but it is associated with the risk of important complications. In our study, we tested the efficacy and safety of peripherally inserted central catheters to manage cardiac intensive care. All patients admitted to cardiac intensive care unit with indication for elective central venous access were checked by venous arm ultrasound for peripherally inserted central catheter's implantation. Peripherally inserted central catheters were inserted by ultrasound-guided puncture. After 7 days from the catheter's placement and at the removal, vascular ultrasound examination was performed searching signs of upper extremity deep venous thrombosis. In case of sepsis, blood cultures peripherally from the catheter and direct culture of the tip of the catheter were done to establish a catheter-related blood stream infection. In our cardiac intensive care unit, 137 peripherally inserted central catheters were placed: 80.3% of patients eligible for a peripherally inserted central catheter were implanted. The rate of symptomatic catheter-related peripheral venous thrombosis was 1.4%. Catheter-related blood stream infection was diagnosed in one patient (0.7%; 5.7 × 1000 peripherally inserted central catheter days). All peripherally inserted central catheters were inserted successfully without other major complications. In patients admitted to cardiac intensive care unit, peripherally inserted central catheters' insertion was feasible in a high percentage of patients and was associated with low infective complications and clinical thrombosis rate.

  9. Exponential Megapriming PCR (EMP) Cloning—Seamless DNA Insertion into Any Target Plasmid without Sequence Constraints

    Science.gov (United States)

    Ulrich, Alexander; Andersen, Kasper R.; Schwartz, Thomas U.

    2012-01-01

    We present a fast, reliable and inexpensive restriction-free cloning method for seamless DNA insertion into any plasmid without sequence limitation. Exponential megapriming PCR (EMP) cloning requires two consecutive PCR steps and can be carried out in one day. We show that EMP cloning has a higher efficiency than restriction-free (RF) cloning, especially for long inserts above 2.5 kb. EMP further enables simultaneous cloning of multiple inserts. PMID:23300917

  10. Exponential megapriming PCR (EMP cloning--seamless DNA insertion into any target plasmid without sequence constraints.

    Directory of Open Access Journals (Sweden)

    Alexander Ulrich

    Full Text Available We present a fast, reliable and inexpensive restriction-free cloning method for seamless DNA insertion into any plasmid without sequence limitation. Exponential megapriming PCR (EMP cloning requires two consecutive PCR steps and can be carried out in one day. We show that EMP cloning has a higher efficiency than restriction-free (RF cloning, especially for long inserts above 2.5 kb. EMP further enables simultaneous cloning of multiple inserts.

  11. Early versus delayed insertion of intrauterine contraception after medical abortion - a randomized controlled trial.

    Directory of Open Access Journals (Sweden)

    Ingrid Sääv

    Full Text Available Today, a large proportion of early abortions are medical terminations, in accordance to the woman's choice. Intrauterine contraceptives (IUC provide highly effective, reversible, long-acting contraception. However, the effects of timing of IUC insertion after medical abortion are not known.Women undergoing medical abortion with mifepristone and misoprostol up to 63 days gestation and opting for IUC were randomised to early insertion (day 5-9 after mifepristone or delayed (routine insertion (at 3-4 weeks after mifepristone. The primary outcome was the rate of IUC expulsion at six months after IUC insertion.A total of 129 women were randomized, and 116 women had a successful IUC insertion. There was no difference in expulsion rate between early (9.7% vs. delayed (7.4% IUC insertion (risk difference -9.2-13.4. Furthermore, 1.5% of women randomized to early and 11.5% to delayed insertion did not attend the follow up (proportion difference 10.0%, 95% CI: 1.8-20.6%, p = 0.015, and a higher proportion of women (41% had had unprotected intercourse prior to returning for insertion in the delayed group compared with the early group (16% (p = 0.015. Adverse events were rare and did not differ between the groups.Early insertion of IUC after medical abortion was safe and well tolerated with no increased incidence for expulsions or complications. Women were more likely to return for the IUC insertion if scheduled early after the abortion, and less likely to have had an unprotected intercourse prior to the IUC insertion. Early insertion should be offered as a routine for women undergoing first trimester medical abortion.ClinicalTrials.gov NCT01537562.

  12. Verification of Triple Modular Redundancy Insertion for Reliable and Trusted Systems

    Science.gov (United States)

    Berg, Melanie; LaBel, Kenneth

    2016-01-01

    If a system is required to be protected using triple modular redundancy (TMR), improper insertion can jeopardize the reliability and security of the system. Due to the complexity of the verification process and the complexity of digital designs, there are currently no available techniques that can provide complete and reliable confirmation of TMR insertion. We propose a method for TMR insertion verification that satisfies the process for reliable and trusted systems.

  13. Enhanced electrical properties of oxide semiconductor thin-film transistors with high conductivity thin layer insertion for the channel region

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Cam Phu Thi; Raja, Jayapal; Kim, Sunbo; Jang, Kyungsoo; Le, Anh Huy Tuan; Lee, Youn-Jung; Yi, Junsin, E-mail: junsin@skku.edu

    2017-02-28

    Highlights: • The characteristics of thin film transistors using double active layers are examined. • Electrical characteristics have been improved for the double active layers devices. • The total trap density can be decreased by insert-ion of ultrathin ITO film. - Abstract: This study examined the performance and the stability of indium tin zinc oxide (ITZO) thin film transistors (TFTs) by inserting an ultra-thin indium tin oxide (ITO) layer at the active/insulator interface. The electrical properties of the double channel device (ITO thickness of 5 nm) were improved in comparison with the single channel ITZO or ITO devices. The TFT characteristics of the device with an ITO thickness of less than 5 nm were degraded due to the formation of an island-like morphology and the carriers scattering at the active/insulator interface. The 5 nm-thick ITO inserted ITZO TFTs (optimal condition) exhibited a superior field effect mobility (∼95 cm{sup 2}/V·s) compared with the ITZO-only TFTs (∼34 cm{sup 2}/V·s). The best characteristics of the TFT devices with double channel layer are due to the lowest surface roughness (0.14 nm) and contact angle (50.1°) that result in the highest hydrophicility, and the most effective adhesion at the surface. Furthermore, the threshold voltage shifts for the ITO/ITZO double layer device decreased to 0.80 and −2.39 V compared with 6.10 and −6.79 V (for the ITZO only device) under positive and negative bias stress, respectively. The falling rates of E{sub A} were 0.38 eV/V and 0.54 eV/V for the ITZO and ITO/ITZO bi-layer devices, respectively. The faster falling rate of the double channel devices suggests that the trap density, including interface trap and semiconductor bulk trap, can be decreased by the ion insertion of a very thin ITO film into the ITZO/SiO{sub 2} reference device. These results demonstrate that the double active layer TFT can potentially be applied to the flat panel display.

  14. Incidence and risk factors of superficial and deep vein thrombosis associated with peripherally inserted central catheters in children.

    Science.gov (United States)

    Menéndez, J J; Verdú, C; Calderón, B; Gómez-Zamora, A; Schüffelmann, C; de la Cruz, J J; de la Oliva, P

    2016-11-01

    Essentials Pediatric studies on peripherally inserted central catheter (PICC)-related thrombosis are scarce. This study analyzes incidence and risk factors for PICC-related venous thrombosis in children. PICC-related thrombosis is a common, and nearly always, asymptomatic complication. Echo-guided insertion and a catheter to vein ratio thrombosis is associated with the use of peripherally inserted central catheters (PICCs). Few pediatric studies have focused on this issue. Objectives To determine the incidence and risk factors for PICC-related superficial vein thrombosis (SVT) and deep vein thrombosis (DVT) in children. Patients/methods An observational follow-up cohort study was conducted at a single hospital between June 2012 and June 2015. All patients receiving a PICC were enrolled and followed up, with weekly Doppler ultrasound examination of the catheterized limb until PICC removal. Patient, procedural and follow-up data were analyzed. Results In the study period, 265 PICCs were inserted (median age of patients 6.5 years, interquartile range [IQR] 2.4-13 years; median weight 20 kg, IQR 11-38 kg; 54% males; 67.9% chronically ill), and patients were followed up for a total of 9743 days. The median indwelling time was 21 days (IQR 12-37 days). During follow-up, 88 (33.2% of insertions) PICC-related thromboses (incidence rate [IR] 9.03 per 1000 catheter-days) were diagnosed, 66 (24.9%) as isolated SVT, seven (2.6%) as isolated DVT, and 15 (5.7%) as SVT with associated DVT (IR 6.78, 0.71 and 1.54 per 1000 catheter-days, respectively). Only 9.9% of patients with SVT and 18.2% of those with DVT were symptomatic. The main risk factors for PICC-related SVT and DVT were a catheter/vein ratio of > 0.33 and thrombosis of the catheterized superficial vein, respectively. Conclusions PICC-related thrombosis is a common and nearly always asymptomatic complication in children, the SVT rate being approximately three times higher than the DVT rate. Optimal vein and catheter

  15. Off-the-shelf in-shoe heel inserts: does cost matter?

    Science.gov (United States)

    Ramanathan, A K; John, M C; Arnold, G P; Cochrane, L A; Abboud, R J

    2008-09-01

    A growing exercise culture has lead to an increase in the use of off-the-shelf heel inserts. While there are a variety of designs in a spectrum of cost ranges, probably the ease of availability and cost would mainly determine the choice of purchase. This study was designed to determine whether expensive designs provide better pressure attenuation under the heel than their less expensive counterparts. Six brands of off-the-shelf heel inserts were tested. Selection of these was based purely on their availability in all sizes. Cost per pair ranged from 6 pounds sterling to 30 pounds sterling. Thirty-five asymptomatic subjects walked on a 10 m walkway, once with no inserts and once with each pair of inserts. The Pedar in-shoe system recorded a range of parameters under the heel. Institute of Motion Analysis and Research, Ninewells Hospital and Medical School, University of Dundee. Evaluation of plantar pressure parameters under the heel. All inserts reduced peak pressure under the heel. Maximum force and pressure-time integral also decreased. Contact time generally increased with the use of inserts. Values of contact area with and without inserts were comparable. No significant differences were observed under the heel between the pressure attenuation properties of the lowest-priced and the most expensive designs, and hence the less expensive inserts can be considered as good as the expensive brands. However, the endurance power of these inserts may differ and this should be evaluated.

  16. Nasogastric tube insertion using airway tube exchanger in anesthetized and intubated patients.

    Science.gov (United States)

    Kim, Hyae-Jin; Lee, Hyeon Jeong; Cho, Hyun-Jun; Kim, Hae-Kyu; Cho, Ah-Reum; Oh, Narae

    2016-12-01

    A nasogastric tube (NGT) is commonly inserted into patients undergoing abdominal surgery to decompress the stomach during or after surgery. However, for anatomic reasons, the insertion of NGTs into anesthetized and intubated patients may be challenging. We hypothesized that the use of a tube exchanger for NGT insertion could increase the success rate and reduce complications. One hundred adult patients, aged 20-70 years, who were scheduled for gastrointestinal surgeries with general anesthesia and NGT insertion were enrolled in our study. The patients were randomly allocated to the tube-exchanger group or the control group. The number of attempts, the time required for successful NGT insertion, and the complications were noted for each patient. In the tube-exchanger group, the success rate of NGT insertion on the first attempt was 92%, which is significantly higher than 68%, the rate in the control group (P = 0.007). The time required for successful NGT insertion in the tube-exchanger group was 18.5 ± 8.2 seconds, which is significantly shorter than the control group, 75.1 ± 9.8 seconds (P tube-exchanger group. There were many advantages in using a tube-exchanger as a guide to inserting NGTs in anesthetized and intubated patients. Compared to the conventional technique, the use of a tube-exchanger resulted in a higher the success rate of insertion on the first attempt, a shorter procedure time, and fewer complications.

  17. Metallographic study of reconstitution welding in inserts of 1 cm3

    International Nuclear Information System (INIS)

    Romero C, J.; Garcia R, R.; Fernandez T, F.; Perez R, N.; Rocamontes A, M.

    2007-01-01

    In this article, the welding metallographic study carried out in Charpy test tubes reconstituted with notch in 'V', used in the surveillance programs of the vessel in nucleo electric plants is described. Inserts of 1 cm 3 are used, where the inserts are usually rectangular of minimum 18 millimeters of length. The importance of using inserts of 1 cm 3 is that the mechanical properties can be measured in another direction of the vessel steel, when changing the direction or sense of the notch in 'V' or the face where this notch is made in the insert. (Author)

  18. Fracture of Reduced-Diameter Zirconia Dental Implants Following Repeated Insertion.

    Science.gov (United States)

    Karl, Matthias; Scherg, Stefan; Grobecker-Karl, Tanja

    Achievement of high insertion torque values indicating good primary stability is a goal during dental implant placement. The objective of this study was to evaluate whether or not two-piece implants made from zirconia ceramic may be damaged as a result of torque application. A total of 10 two-piece zirconia implants were repeatedly inserted into polyurethane foam material with increasing density and decreasing osteotomy size. The insertion torque applied was measured, and implants were checked for fractures by applying the fluorescent penetrant method. Weibull probability of failure was calculated based on the recorded insertion torque values. Catastrophic failures could be seen in five of the implants from two different batches at insertion torques ranging from 46.0 to 70.5 Ncm, while the remaining implants (all belonging to one batch) survived. Weibull probability of failure seems to be low at the manufacturer-recommended maximum insertion torque of 35 Ncm. Chipping fractures at the thread tips as well as tool marks were the only otherwise observed irregularities. While high insertion torques may be desirable for immediate loading protocols, zirconia implants may fracture when manufacturer-recommended insertion torques are exceeded. Evaluating bone quality prior to implant insertion may be useful.

  19. Characterization of Tn904 insertions in octopine Ti plasmid mutants of Agrobacterium tumefaciens.

    Science.gov (United States)

    Ooms, G; Klapwijk, P M; Poulis, J A; Schilperoort, R A

    1980-01-01

    Seven Tn904 insertion mutants of pTi Ach5 affecting Agrobacterium tumefaciens virulence were studied. The mutant character was shown to be plasmid borne. Four of these mutants were avirulent and carried an insertion in restriction endonuclease HpaI fragment 12, a 3.3-megadalton fragment, which therefore appears to be a Ti plasmid region essential for virulence. Two mutants were attenuated in virulence. The inserts mapped close to HpaI fragment 12. One mutant giving rise to small tumors with excessive adventitious root formation on Kalanchoe daigremontiana carried an insertion in the right side of the common sequence in the deoxyribonucleic acid of the Ti plasmid detected in crown gall tumors. The insertion behavior of Tn904 was studied by analyzing 11 independently isolated and randomly chosen mutants. The Tn904 inserts did not affect oncogenicity, tumor morphology, bacterial transfer functions, octopine catabolism functions, or vital parts of the Ti plasmid, such as the origin of replication. Most of the Tn904 inserts were concentrated in a small part of the map. The size of additional deoxyribonucleic acid as a result of Tn904 inserts varied between 5 and 15 megadaltons. In two cases a Ti plasmid was found with two Tn904 insertions at different positions. Images PMID:6252198

  20. Unicortical self-drilling external fixator pins reduce thermal effects during pin insertion.

    Science.gov (United States)

    Greinwald, Markus; Varady, Patrick A; Augat, Peter

    2017-12-14

    External fixation is associated with the risk of pin loosening and pin infection potentially associated to thermal bone necrosis during pin insertion. This study aims to investigate if the use of external fixator systems with unicortical pins reduces the heat production during pin insertion compared to fixators with bicortical pins. Porcine bone specimens were employed to determine bone temperatures during insertion of fixator pins. Two thermographic cameras were used for a simultaneous temperature measurement on the bone surface (top view) and a bone cross-section (front view). Self-drilling unicortical and bicortical pins were inserted at different rotational speeds: (30-600) rpm. Maximum and mean temperatures of the emerging bone debris, bone surface and bone cross-section were analyzed. Maximum temperatures of up to 77 ± 26 °C were measured during pin insertion in the emerging debris and up to 42 ± 2 °C on the bone surface. Temperatures of the emerging debris increased with increasing rotational speeds. Bicortical pin insertion generated significantly higher temperatures at low insertion speed (30 rpm) CONCLUSION: The insertion of external fixator pins can generate a considerable amount of heat around the pins, primarily emerging from bone debris and at higher insertion speeds. Our findings suggest that unicortical, self-drilling fixator pins have a decreased risk for thermal damage, both to the surrounding tissue and to the bone itself.