WorldWideScience

Sample records for single subject designs

  1. The Utility of Single Subject Design Research

    Science.gov (United States)

    Bennett, Kyle D.

    2016-01-01

    Single subject design (SSD) research is a quantitative approach used to investigate basic and applied research questions. It has been used for decades to examine issues of social importance such as those related to general and special education strategies, therapeutic approaches in mental health, community health practices, safety, and business…

  2. Handbook of statistical methods single subject design

    CERN Document Server

    Satake, Eiki; Maxwell, David L

    2008-01-01

    This book is a practical guide of the most commonly used approaches in analyzing and interpreting single-subject data. It arranges the methodologies used in a logical sequence using an array of research studies from the existing published literature to illustrate specific applications. The book provides a brief discussion of each approach such as visual, inferential, and probabilistic model, the applications for which it is intended, and a step-by-step illustration of the test as used in an actual research study.

  3. Creating single-subject design graphs in Microsoft Excel 2007.

    Science.gov (United States)

    Dixon, Mark R; Jackson, James W; Small, Stacey L; Horner-King, Mollie J; Lik, Nicholas Mui Ker; Garcia, Yors; Rosales, Rocio

    2009-01-01

    Over 10 years have passed since the publication of Carr and Burkholder's (1998) technical article on how to construct single-subject graphs using Microsoft Excel. Over the course of the past decade, the Excel program has undergone a series of revisions that make the Carr and Burkholder paper somewhat difficult to follow with newer versions. The present article provides task analyses for constructing various types of commonly used single-subject design graphs in Microsoft Excel 2007. The task analyses were evaluated using a between-subjects design that compared the graphing skills of 22 behavior-analytic graduate students using Excel 2007 and either the Carr and Burkholder or newly developed task analyses. Results indicate that the new task analyses yielded more accurate and faster graph construction than the Carr and Burkholder instructions.

  4. SSDOnt: An Ontology for Representing Single-Subject Design Studies.

    Science.gov (United States)

    Berges, Idoia; Bermúdez, Jesus; Illarramendi, Arantza

    2018-02-01

    Single-Subject Design is used in several areas such as education and biomedicine. However, no suited formal vocabulary exists for annotating the detailed configuration and the results of this type of research studies with the appropriate granularity for looking for information about them. Therefore, the search for those study designs relies heavily on a syntactical search on the abstract, keywords or full text of the publications about the study, which entails some limitations. To present SSDOnt, a specific purpose ontology for describing and annotating single-subject design studies, so that complex questions can be asked about them afterwards. The ontology was developed following the NeOn methodology. Once the requirements of the ontology were defined, a formal model was described in a Description Logic and later implemented in the ontology language OWL 2 DL. We show how the ontology provides a reference model with a suitable terminology for the annotation and searching of single-subject design studies and their main components, such as the phases, the intervention types, the outcomes and the results. Some mappings with terms of related ontologies have been established. We show as proof-of-concept that classes in the ontology can be easily extended to annotate more precise information about specific interventions and outcomes such as those related to autism. Moreover, we provide examples of some types of queries that can be posed to the ontology. SSDOnt has achieved the purpose of covering the descriptions of the domain of single-subject research studies. Schattauer GmbH.

  5. The Applied Behavior Analysis Research Paradigm and Single-Subject Designs in Adapted Physical Activity Research.

    Science.gov (United States)

    Haegele, Justin A; Hodge, Samuel Russell

    2015-10-01

    There are basic philosophical and paradigmatic assumptions that guide scholarly research endeavors, including the methods used and the types of questions asked. Through this article, kinesiology faculty and students with interests in adapted physical activity are encouraged to understand the basic assumptions of applied behavior analysis (ABA) methodology for conducting, analyzing, and presenting research of high quality in this paradigm. The purposes of this viewpoint paper are to present information fundamental to understanding the assumptions undergirding research methodology in ABA, describe key aspects of single-subject research designs, and discuss common research designs and data-analysis strategies used in single-subject studies.

  6. Single-subject withdrawal designs in delayed matching-to-sample procedures

    OpenAIRE

    Eilifsen, Christoffer; Arntzen, Erik

    2011-01-01

    In most studies of delayed matching-to-sample (DMTS) and stimulus equivalence, the delay has remained fixed throughout a single experimental condition. We wanted to expand on the DMTS and stimulus equivalence literature by examining the effects of using titrating delays with different starting points during the establishment of conditional discriminations prerequisite for stimulus equivalence. In Experiment 1, a variation of a single-subject withdrawal design was used. Ten adults were exposed...

  7. Bias Corrections for Standardized Effect Size Estimates Used with Single-Subject Experimental Designs

    Science.gov (United States)

    Ugille, Maaike; Moeyaert, Mariola; Beretvas, S. Natasha; Ferron, John M.; Van den Noortgate, Wim

    2014-01-01

    A multilevel meta-analysis can combine the results of several single-subject experimental design studies. However, the estimated effects are biased if the effect sizes are standardized and the number of measurement occasions is small. In this study, the authors investigated 4 approaches to correct for this bias. First, the standardized effect…

  8. Rating the methodological quality of single-subject designs and n-of-1 trials: introducing the Single-Case Experimental Design (SCED) Scale.

    Science.gov (United States)

    Tate, Robyn L; McDonald, Skye; Perdices, Michael; Togher, Leanne; Schultz, Regina; Savage, Sharon

    2008-08-01

    Rating scales that assess methodological quality of clinical trials provide a means to critically appraise the literature. Scales are currently available to rate randomised and non-randomised controlled trials, but there are none that assess single-subject designs. The Single-Case Experimental Design (SCED) Scale was developed for this purpose and evaluated for reliability. Six clinical researchers who were trained and experienced in rating methodological quality of clinical trials developed the scale and participated in reliability studies. The SCED Scale is an 11-item rating scale for single-subject designs, of which 10 items are used to assess methodological quality and use of statistical analysis. The scale was developed and refined over a 3-year period. Content validity was addressed by identifying items to reduce the main sources of bias in single-case methodology as stipulated by authorities in the field, which were empirically tested against 85 published reports. Inter-rater reliability was assessed using a random sample of 20/312 single-subject reports archived in the Psychological Database of Brain Impairment Treatment Efficacy (PsycBITE). Inter-rater reliability for the total score was excellent, both for individual raters (overall ICC = 0.84; 95% confidence interval 0.73-0.92) and for consensus ratings between pairs of raters (overall ICC = 0.88; 95% confidence interval 0.78-0.95). Item reliability was fair to excellent for consensus ratings between pairs of raters (range k = 0.48 to 1.00). The results were replicated with two independent novice raters who were trained in the use of the scale (ICC = 0.88, 95% confidence interval 0.73-0.95). The SCED Scale thus provides a brief and valid evaluation of methodological quality of single-subject designs, with the total score demonstrating excellent inter-rater reliability using both individual and consensus ratings. Items from the scale can also be used as a checklist in the design, reporting and critical

  9. Can Constraint Induced Movement Therapy Improve In-Hand Manipulation Skills: A Single Subject Design

    Directory of Open Access Journals (Sweden)

    Somaye Kavousipor

    2012-04-01

    Full Text Available Objectives: This study describes a single subject design (ABA that shows the effective use of constraint induced movement therapy in improvement of quality and performance of in-hand manipulation skills for a 10 year old boy and a 9 years old girl with hemiplegic cerebral palsy, as Dickerson (2007 showed it in arm movement and function. Methods: To determine the effectiveness of CIMT by the use of C-statistic analysis and visual analysis. Approach: The first step was to design a child friendly group activity and home based intervention program through occupation. The possible effectiveness of CIMT was evaluated by daily measurements and video recording of 6 sub skills of in-hand manipulation according to Pont category (2009 in defined activity. Results: For making the treatment more cost effective, families can produce a simple clinical setting at home and participate in their child treatment plan actively. Discussion: A client center intervention will facilitate the use and quality of fingers and hand motion. Also a group activity can motivate participants to participate more and better.

  10. Quality Appraisal of Single-Subject Experimental Designs: An Overview and Comparison of Different Appraisal Tools

    Science.gov (United States)

    Wendt, Oliver; Miller, Bridget

    2012-01-01

    Critical appraisal of the research literature is an essential step in informing and implementing evidence-based practice. Quality appraisal tools that assess the methodological quality of experimental studies provide a means to identify the most rigorous research suitable for evidence-based decision-making. In single-subject experimental research,…

  11. Creating Single-Subject Design Graphs in Microsoft Excel[TM] 2007

    Science.gov (United States)

    Dixon, Mark R.; Jackson, James W.; Small, Stacey L.; Horner-King, Mollie J.; Mui Ker Lik, Nicholas; Garcia, Yors; Rosales, Rocio

    2009-01-01

    Over 10 years have passed since the publication of Carr and Burkholder's (1998) technical article on how to construct single-subject graphs using Microsoft Excel. Over the course of the past decade, the Excel program has undergone a series of revisions that make the Carr and Burkholder paper somewhat difficult to follow with newer versions. The…

  12. The influence of the design matrix on treatment effect estimates in the quantitative analyses of single-subject experimental design research.

    Science.gov (United States)

    Moeyaert, Mariola; Ugille, Maaike; Ferron, John M; Beretvas, S Natasha; Van den Noortgate, Wim

    2014-09-01

    The quantitative methods for analyzing single-subject experimental data have expanded during the last decade, including the use of regression models to statistically analyze the data, but still a lot of questions remain. One question is how to specify predictors in a regression model to account for the specifics of the design and estimate the effect size of interest. These quantitative effect sizes are used in retrospective analyses and allow synthesis of single-subject experimental study results which is informative for evidence-based decision making, research and theory building, and policy discussions. We discuss different design matrices that can be used for the most common single-subject experimental designs (SSEDs), namely, the multiple-baseline designs, reversal designs, and alternating treatment designs, and provide empirical illustrations. The purpose of this article is to guide single-subject experimental data analysts interested in analyzing and meta-analyzing SSED data. © The Author(s) 2014.

  13. Optimum design of a Lanchester damper for a viscously damped single degree of freedom system subjected to inertial excitation

    Science.gov (United States)

    Bapat, V. A.; Prabhu, P.

    1980-11-01

    The problem of designing an optimum Lanchester damper for a viscously damped single degree of freedom system subjected to inertial harmonic excitation is investigated. Two criteria are used for optimizing the performance of the damper: (i) minimum motion transmissibility; (ii) minimum force transmissibility. Explicit expressions are developed for determining the absorber parameters.

  14. Evidence-Based Communication Practices for Children with Visual Impairments and Additional Disabilities: An Examination of Single-Subject Design Studies

    Science.gov (United States)

    Parker, Amy T.; Grimmett, Eric S.; Summers, Sharon

    2008-01-01

    This review examines practices for building effective communication strategies for children with visual impairments, including those with additional disabilities, that have been tested by single-subject design methodology. The authors found 30 studies that met the search criteria and grouped intervention strategies to align any evidence of the…

  15. Effects of Oral Stimulation Intervention in Newborn Babies with Cri du Chat Syndrome: Single-Subject Research Design

    Directory of Open Access Journals (Sweden)

    Mi Kyung Kim

    2018-01-01

    Full Text Available The purpose of this study is to treat dysphagia in a newborn baby with cri du chat syndrome using an oral stimulation intervention and to examine its effects. The subject of this study was a baby born 2 weeks prematurely. Since birth, his oxygen saturation (SaO2 decreased while feeding, and he had difficulty with mouth feeding. Thus, an NG feeding tube was inserted, and dysphagia treatment was initiated on the sixth day after birth. A baseline phase and an intervention phase were performed using an AB design. The oral stimulation intervention was not performed in the baseline phase, as only nonnutritive sucking training using a rubber pacifier was used during the baseline phase. During the intervention phase, nonnutritive sucking training and oral stimulation intervention were simultaneously conducted. After the intervention period, daily oral milk intake and intake per feeding of the subject noticeably increased. The oxygen saturation while feeding rose over 90% on average, and the baby did not present with hypoxia. The oral stimulation intervention provided prior to feeding resulted in highly positive effects, including induced normal development of the baby, stimulation of his transition from the NG feeding tube to bottle feeding, increased oxygen saturation, and a shortened hospital stay.

  16. Single Subject Research: Applications to Special Education

    Science.gov (United States)

    Cakiroglu, Orhan

    2012-01-01

    Single subject research is a scientific research methodology that is increasingly used in the field of special education. Therefore, understanding the unique characteristics of single subject research methodology is critical both for educators and practitioners. Certain characteristics make single subject research one of the most preferred…

  17. Case study: videogame distraction reduces behavioral distress in a preschool-aged child undergoing repeated burn dressing changes: a single-subject design.

    Science.gov (United States)

    Sil, Soumitri; Dahlquist, Lynnda M; Burns, Andrew J

    2013-04-01

    This single-subject design study evaluated the feasibility and efficacy of passive and interactive videogame distraction on behavioral distress for a preschool-aged child receiving repeated burn dressing changes. A 4-year-old girl underwent 3 baseline and 10 videogame distraction sessions (5 passive and 5 interactive) using a restricted alternating treatments design. Observed behavioral distress was coded, and parents and nurses rated the child's distress and cooperative behavior. Relative to baseline, behavioral distress decreased and cooperative behavior increased immediately after the onset of videogame distraction. Single Case Randomization Tests revealed significantly lower behavioral distress and greater cooperation during interactive videogame distraction relative to passive videogame distraction. Interactive videogame distraction appears to be a feasible and effective pain management strategy for a preschool-aged child undergoing repeated painful medical procedures.

  18. Exposure-based cognitive behavioral therapy for irritable bowel syndrome. A single-case experimental design across 13 subjects.

    Science.gov (United States)

    Boersma, Katja; Ljótsson, Brjánn; Edebol-Carlman, Hanna; Schrooten, Martien; Linton, Steven J; Brummer, Robert J

    2016-11-01

    Irritable bowel syndrome (IBS) is a highly prevalent disorder with a significant impact on quality of life. The presence of psychological symptoms in IBS patients such as catastrophic worry and behavioral avoidance suggests the possible efficacy of cognitive behavioral interventions. Exposure-based cognitive behavioral therapy (CBT) has proven to be a promising approach but has only been investigated in a few studies and mainly via the Internet. Therefore, the aims of this study were to extend and replicate previous findings and to evaluate whether an individual, face-to-face, exposure-based CBT leads to improvement in gastrointestinal symptoms, pain catastrophizing, avoidance behavior and quality of life in IBS patients. Thirteen patients with IBS according to Rome III criteria participated in a single-case experimental study using a five-week baseline and a subsequent twelve-session intervention phase focusing on psycho-education, mindfulness and in vivo exposure. Standardized measurement of gastrointestinal symptoms, pain catastrophizing, avoidance behavior and quality of life was conducted weekly during baseline as well as intervention phase and at six-month follow-up. Results showed that over 70% of patients improved significantly on gastrointestinal symptoms, pain catastrophizing, and quality of life. Effects on avoidance behavior were modest. These results strengthen and extend earlier findings and provide further support for the efficacy of exposure-based strategies for IBS.

  19. The effect of a motor-based, social skills intervention for adolescents with high-functioning autism: two single-subject design cases.

    Science.gov (United States)

    Gutman, Sharon A; Raphael, Emily I; Ceder, Leila M; Khan, Arshi; Timp, Katherine M; Salvant, Sabrina

    2010-12-01

    The purpose of this study was to assess the effect of a motor-based, social skills intervention for two adolescents with high-functioning autism (HFA) using single-subject design. A description of the intervention is provided as a first step in the manualization process. The intervention was provided as a 7-week after-school program, once weekly to the paired participants. Intervention consisted of role-play methods in which motor behaviours were linked with their cognitive and emotional meanings. Baseline, intervention and 3-month probe data collection periods were carried out and then compared using visual inspection of graphed data, paired t-tests and a three-standard-deviation-band approach. Both participants displayed a statistically significant increase in targeted social skills behaviours from baseline to intervention and maintained this level at a 3-month post-intervention probe. These single-subject design cases illustrate that motor-based, social skills interventions may be effective for adolescents with HFA and warrant further testing. Copyright © 2010 John Wiley & Sons, Ltd.

  20. Single-Subject Research Methodology: An Underutilized Tool in the Field of Deafness.

    Science.gov (United States)

    Bullis, Michael; Anderson, Glenn

    1986-01-01

    Single-subject research methods are simple, powerful, and very applicable to selected study of deafness. This article considers group versus single-subject designs; an example of withdrawal single-subject design; and an example of the multiple baseline single-subject design. (CB)

  1. Knowledge of results and learning to tell the time in an adult male with an intellectual disability: a single-subject research design.

    Science.gov (United States)

    Applegate, Samantha L; Rice, Martin S; Stein, Franklin; Maitra, Kinsuk K

    2008-01-01

    The present study investigated whether knowledge of results, in the form of visual and audible feedback, would increase the accuracy of time-telling in an individual with an intellectual disability. A 19-year-old male with mild intellectual disability participated in this A1-B1-A2-B2 single-subject study design. The task involved correctly identifying the time given on a computer. Data, based on the Wilcoxon signed-rank test, showed that the participant demonstrated a greater number of correct responses during the intervention phases. Incorporating knowledge of results into a learning strategy for this individual with intellectual disability resulted in an increased ability to accurately identify the correct time on an analogue clock. There is a need to replicate the study design to increase the external validity and generalization of results. The strategies described in the present study may also be useful for occupational therapists who teach individuals with intellectual disability to gain skills in their everyday activities of daily living (ADLs). (c) 2007 John Wiley & Sons, Ltd.

  2. Comparison of forward versus backward walking using body weight supported treadmill training in an individual with a spinal cord injury: a single subject design.

    Science.gov (United States)

    Moriello, Gabriele; Pathare, Neeti; Cirone, Cono; Pastore, Danielle; Shears, Dacia; Sulehri, Sahira

    2014-01-01

    Body weight supported treadmill training (BWSTT) is a task-specific intervention that promotes functional locomotion. There is no research evaluating the effect of backward walking (BW) using BWSTT in individuals with spinal cord injury (SCI). The purpose of this single subject design was to examine the differences between forward walking (FW) and BW training using BWSTT in an individual with quadriparesis. The participant was a 57-year-old male with incomplete C3-C6 SCI. An ABABAB design (A = BW; B = FW; each phase = 3 weeks of biweekly sessions) was utilized. Outcome measures included: gait parameters; a timed 4-meter walk; the 5-repetition sit-to-stand test (STST); tandem stance time; and 6-minute walk test (6MWT). Data was analyzed with split level method of trend estimation. Improvements in gait parameters, on the timed 4-meter walk, 6MWT, tandem balance and aerobic endurance were similar with FW and BW training. The only difference between FW and BW training was that BW training resulted in greater improvements in the STST. The results of this study suggest that in this individual backward walking training was advantageous, resulting in improved ability to perform the 5-repetition STST. It is suspected that these changes can be attributed to the differences in muscle activation and task difficulty between FW and BW.

  3. The Reliability of Single Subject Statistics for Biofeedback Studies.

    Science.gov (United States)

    Bremner, Frederick J.; And Others

    To test the usefulness of single subject statistical designs for biofeedback, three experiments were conducted comparing biofeedback to meditation, and to a compound stimulus recognition task. In a statistical sense, this experimental design is best described as one experiment with two replications. The apparatus for each of the three experiments…

  4. Internet-Based Cognitive Behavioral Therapy for Residual Symptoms in Bipolar Disorder Type II: A Single-Subject Design Pilot Study.

    Science.gov (United States)

    Holländare, Fredrik; Eriksson, Annsofi; Lövgren, Lisa; Humble, Mats B; Boersma, Katja

    2015-04-23

    Bipolar disorder is a chronic condition with recurring episodes that often lead to suffering, decreased functioning, and sick leave. Pharmacotherapy in the form of mood stabilizers is widely available, but does not eliminate the risk of a new depressive or (hypo)manic episode. One way to reduce the risk of future episodes is to combine pharmacological treatment with individual or group psychological interventions. However, access to such interventions is often limited due to a shortage of trained therapists. In unipolar depression there is now robust evidence of the effectiveness of Internet-based psychological interventions, usually comprising psychoeducation and cognitive behavioral therapy (CBT). Internet-based interventions for persons suffering from bipolar disorder could increase access to psychological treatment. The aim of this study was to investigate the feasibility of an Internet-based intervention, as well as its effect on residual depressive symptoms in persons diagnosed with bipolar disorder type II (BP-II). The most important outcomes were depressive symptoms, treatment adherence, and whether the patient perceived the intervention as helpful. A total of 7 patients diagnosed with bipolar disorder type II at a Swedish psychiatric outpatient clinic were offered the opportunity to participate. Of the 7 patients, 3 (43%) dropped out before treatment began, and 4 (57%) were treated by means of an online, Internet-based intervention based on CBT (iCBT). The intervention was primarily aimed at psychoeducation, treatment of residual depressive symptoms, emotion regulation, and improved sleep. All patients had ongoing pharmacological treatment at recruitment and established contact with a psychiatrist. The duration of BP-II among the treated patients was between 6 and 31 years. A single-subject design was used and the results of the 4 participating patients were presented individually. Initiating treatment was perceived as too demanding under current life

  5. Acute and chronic effects of aquatic treadmill training on land treadmill running kinematics: A cross-over and single-subject design approach.

    Science.gov (United States)

    Bressel, Eadric; Louder, Talin J; Hoover, James P; Roberts, Luke C; Dolny, Dennis G

    2017-11-01

    The aim of this study was to determine if selected kinematic measures (foot strike index [SI], knee contact angle and overstride angle) were different between aquatic treadmill (ATM) and land treadmill (LTM) running, and to determine if these measures were altered during LTM running as a result of 6 weeks of ATM training. Acute effects were tested using 15 competitive distance runners who completed 1 session of running on each treadmill type at 5 different running speeds. Subsequently, three recreational runners completed 6 weeks of ATM training following a single-subject baseline, intervention and withdrawal experiment. Kinematic measures were quantified from digitisation of video. Regardless of speed, SI values during ATM running (61.3 ± 17%) were significantly greater (P = 0.002) than LTM running (42.7 ± 23%). Training on the ATM did not change (pre/post) the SI (26 ± 3.2/27 ± 3.1), knee contact angle (165 ± 0.3/164 ± 0.8) or overstride angle (89 ± 0.4/89 ± 0.1) during LTM running. Although SI values were different between acute ATM and LTM running, 6 weeks of ATM training did not appear to alter LTM running kinematics as evidenced by no change in kinematic values from baseline to post intervention assessments.

  6. Safety and feasibility of transcranial direct current stimulation in amyotrophic lateral sclerosis - a pilot study with a single subject experimental design.

    Science.gov (United States)

    Madhavan, Sangeetha; Sivaramakrishnan, Anjali; Bond, Sam; Jiang, Qin Li

    2018-02-28

    Transcranial direct current stimulation (tDCS) has been explored as a neuromodulatory tool to prime motor function in several neurological disorders. Studies using tDCS in amyotrophic lateral sclerosis (ALS) are limited. We investigated the safety, feasibility and effects of long-term tDCS in an individual with ALS. A 36-year-old male diagnosed with clinically definite ALS received 12 sessions each of anodal, sham, and cathodal tDCS. Outcome measures included disease progression (revised ALS functional rating scale (ALSFRS-R)), clinical measures of endurance and mobility, and corticomotor excitability. No adverse events or change in disease progression were noticed during the study. Small improvement in gait speed (15% increase) was noticed with anodal tDCS only. This case study demonstrates the safety and feasibility of long-term facilitatory and inhibitory tDCS on a single participant with ALS. This study serves as a guideline for implementing tDCS in future ALS trials.

  7. Single liner shipping service design

    DEFF Research Database (Denmark)

    Plum, Christian Edinger Munk; Pisinger, David; Salazar-González, Juan-José

    2014-01-01

    The design of container shipping networks is an important logistics problem, involving assets and operational costs measured in billions of dollars. To guide the optimal deployment of the ships, a single vessel round trip is considered by minimizing operational costs and flowing the best paying...

  8. Single wire drift chamber design

    International Nuclear Information System (INIS)

    Krider, J.

    1987-01-01

    This report summarizes the design and prototype tests of single wire drift chambers to be used in Fermilab test beam lines. The goal is to build simple, reliable detectors which require a minimum of electronics. Spatial resolution should match the 300 μm rms resolution of the 1 mm proportional chambers that they will replace. The detectors will be used in beams with particle rates up to 20 KHz. Single track efficiency should be at least 99%. The first application will be in the MT beamline, which has been designed for calibration of CDF detectors. A set of four x-y modules will be used to track and measure the momentum of beam particles

  9. A comparison of the effects of visual deprivation and regular body weight support treadmill training on improving over-ground walking of stroke patients: a multiple baseline single subject design.

    Science.gov (United States)

    Kim, Jeong-Soo; Kang, Sun-Young; Jeon, Hye-Seon

    2015-01-01

    The body-weight-support treadmill (BWST) is commonly used for gait rehabilitation, but other forms of BWST are in development, such as visual-deprivation BWST (VDBWST). In this study, we compare the effect of VDBWST training and conventional BWST training on spatiotemporal gait parameters for three individuals who had hemiparetic strokes. We used a single-subject experimental design, alternating multiple baselines across the individuals. We recruited three individuals with hemiparesis from stroke; two on the left side and one on the right. For the main outcome measures we assessed spatiotemporal gait parameters using GAITRite, including: gait velocity; cadence; step time of the affected side (STA); step time of the non-affected side (STN); step length of the affected side (SLA); step length of the non-affected side (SLN); step-time asymmetry (ST-asymmetry); and step-length asymmetry (SL-asymmetry). Gait velocity, cadence, SLA, and SLN increased from baseline after both interventions, but STA, ST-asymmetry, and SL-asymmetry decreased from the baseline after the interventions. The VDBWST was significantly more effective than the BWST for increasing gait velocity and cadence and for decreasing ST-asymmetry. VDBWST is more effective than BWST for improving gait performance during the rehabilitation for ground walking.

  10. Early Intervention for Children with Conduct Disorders: A Quantitative Synthesis of Single-Subject Research.

    Science.gov (United States)

    Scruggs, Thomas E.; And Others

    1986-01-01

    Sixteen studies were analyzed that employed single-subject designs focusing on conduct disorders in preschoolers. Results indicated that reinforcement produced most positive outcomes, followed by punishment, timeout, and differential attention. Subject characteristics such as sex, handicapping condition, and target behavior typically bore little…

  11. Evaluation on Behavior of Single Block Subject to Harmonic Excitation

    International Nuclear Information System (INIS)

    Choi, Woo-Seok; Kim, Dong-Ok; Park, Keun-Bae; Lee, Won-Jae

    2007-01-01

    NHDD(Nuclear Hydrogen Development and Demonstration) project team in KAERI(Korea Atomic Energy Research Institute) has been developing a methodology on the seismic evaluation of VHTR(Very High Temperature Reactor). Roughly, there are a block type and a pebble type reactor in VHTR. In the block type reactor, several blocks are stacked and the stacked blocks are arrayed in certain pattern. To evaluate a behavior style and an integrity of the stacked structure subject to a seismic load, a modeling technique to represent the contact surface characteristics between a block and a block support structure and between blocks is necessary. The way to evaluate a load path is also needed. However, it is difficult to deal with a realistic seismic load and to figure out the characteristic of block behavior since it has very complicated time history. In this study, the evaluation of single block subject to a harmonic excitation is conducted for a preliminary evaluation

  12. Future steam generator designs. Single wall designs

    Energy Technology Data Exchange (ETDEWEB)

    Hayden, O [Nuclear Power Company Ltd, Warrington, Cheshire (United Kingdom)

    1978-10-01

    The easily removable 'U' tube design style adopted in the UK for the existing PFR Steam Generators, the Replacement Units now in production and for the future CDFR, gives the operator an extremely valuable option in the event of a water/steam leak occurring inside the Steam Generator. He can choose to shut-down, attempt to find the leak, assess damage, repair, revalidate and return to service in situ, or he can elect to remove the defect unit and replace with a 'proven' spare before returning the circuit to power. With the latter approach the resultant outage time is a known entity of about two weeks. If a repair is attempted in situ, predictions of outage time can become a matter of guesswork since one has no 'guaranteed' method of leak location and the assessment of secondary damage may be very time consuming, depending on the size and type of the original leak together with the particular design style of the Steam Generator. A further significant advantage of the removable 'U' tube design concept is that periodic interchanging of bundles with a spare enables routine chemical cleaning and thorough scheduled tube inspections, with specimen tube sample removal if required for monitoring purposes. If necessary, bundle decontamination can be undertaken to assess engineering deterioration to various degrees of thoroughness ranging from 100% equivalent factory final assembly inspection, to partial decontamination operating via a glovebox type of maintenance bag arrangement, examining local points of both shell and tube areas of the bundle. Many lessons from the last five years' experience of PFR will be incorporated into the design of the CDFR and PFR Steam Generators have two very good examples of how the designer can ease or severely handicap the operator in coping with sodium/water leakages. Good, quick access to tube ends is achieved in the existing PFR Evaporator by simply unbolting the steam/water closure head, but on the superheater and reheater hand-caps have

  13. Future steam generator designs. Single wall designs

    International Nuclear Information System (INIS)

    Hayden, O.

    1978-01-01

    The easily removable 'U' tube design style adopted in the UK for the existing PFR Steam Generators, the Replacement Units now in production and for the future CDFR, gives the operator an extremely valuable option in the event of a water/steam leak occurring inside the Steam Generator. He can choose to shut-down, attempt to find the leak, assess damage, repair, revalidate and return to service in situ, or he can elect to remove the defect unit and replace with a 'proven' spare before returning the circuit to power. With the latter approach the resultant outage time is a known entity of about two weeks. If a repair is attempted in situ, predictions of outage time can become a matter of guesswork since one has no 'guaranteed' method of leak location and the assessment of secondary damage may be very time consuming, depending on the size and type of the original leak together with the particular design style of the Steam Generator. A further significant advantage of the removable 'U' tube design concept is that periodic interchanging of bundles with a spare enables routine chemical cleaning and thorough scheduled tube inspections, with specimen tube sample removal if required for monitoring purposes. If necessary, bundle decontamination can be undertaken to assess engineering deterioration to various degrees of thoroughness ranging from 100% equivalent factory final assembly inspection, to partial decontamination operating via a glovebox type of maintenance bag arrangement, examining local points of both shell and tube areas of the bundle. Many lessons from the last five years' experience of PFR will be incorporated into the design of the CDFR and PFR Steam Generators have two very good examples of how the designer can ease or severely handicap the operator in coping with sodium/water leakages. Good, quick access to tube ends is achieved in the existing PFR Evaporator by simply unbolting the steam/water closure head, but on the superheater and reheater hand-caps have

  14. Microarray expression profiling of human dental pulp from single subject.

    Science.gov (United States)

    Tete, Stefano; Mastrangelo, Filiberto; Scioletti, Anna Paola; Tranasi, Michelangelo; Raicu, Florina; Paolantonio, Michele; Stuppia, Liborio; Vinci, Raffaele; Gherlone, Enrico; Ciampoli, Cristian; Sberna, Maria Teresa; Conti, Pio

    2008-01-01

    Microarray is a recently developed simultaneous analysis of expression patterns of thousand of genes. The aim of this research was to evaluate the expression profile of human healthy dental pulp in order to find the presence of genes activated and encoding for proteins involved in the physiological process of human dental pulp. We report data obtained by analyzing expression profiles of human tooth pulp from single subjects, using an approach based on the amplification of the total RNA. Experiments were performed on a high-density array able to analyse about 21,000 oligonucleotide sequences of about 70 bases in duplicate, using an approach based on the amplification of the total RNA from the pulp of a single tooth. Obtained data were analyzed using the S.A.M. system (Significance Analysis of Microarray) and genes were merged according to their molecular functions and biological process by the Onto-Express software. The microarray analysis revealed 362 genes with specific pulp expression. Genes showing significant high expression were classified in genes involved in tooth development, protoncogenes, genes of collagen, DNAse, Metallopeptidases and Growth factors. We report a microarray analysis, carried out by extraction of total RNA from specimens of healthy human dental pulp tissue. This approach represents a powerful tool in the study of human normal and pathological pulp, allowing minimization of the genetic variability due to the pooling of samples from different individuals.

  15. Subjective knowledge and fear appeal effectiveness: implications for message design.

    Science.gov (United States)

    Nabi, Robin L; Roskos-Ewoldsen, David; Carpentier, Francesca Dillman

    2008-01-01

    This research investigates the role of perceived health knowledge on the effectiveness of fear-based persuasive appeals. Undergraduates (N = 263) read a strong fear, weak fear, or efficacy-only message encouraging breast or testicular self-examination. As expected, results indicated that men high in subjective knowledge were less reactant and more persuaded by the efficacy-only message whereas those low in subjective knowledge did not evidence this pattern. Contrary to expectation, women high in subjective knowledge had comparable reactions to each of the 3 messages. Implications for fear appeal theory and message design are discussed.

  16. Single-Case Designs and Qualitative Methods: Applying a Mixed Methods Research Perspective

    Science.gov (United States)

    Hitchcock, John H.; Nastasi, Bonnie K.; Summerville, Meredith

    2010-01-01

    The purpose of this conceptual paper is to describe a design that mixes single-case (sometimes referred to as single-subject) and qualitative methods, hereafter referred to as a single-case mixed methods design (SCD-MM). Minimal attention has been given to the topic of applying qualitative methods to SCD work in the literature. These two…

  17. Design for subjective well-being in interior architecture

    NARCIS (Netherlands)

    Petermans, A.; Pohlmeyer, A.E.

    2014-01-01

    Can interior environments engage people in pleasurable and meaningful experiences and thereby have a positive influence on their happiness? This paper discusses why and how interior architects might want to consider implementing ideas in relation to ‘design for subjective well-being’. Despite of

  18. Single Trial Probability Applications: Can Subjectivity Evade Frequency Limitations?

    Directory of Open Access Journals (Sweden)

    David Howden

    2009-10-01

    Full Text Available Frequency probability theorists define an event’s probability distribution as the limit of a repeated set of trials belonging to a homogeneous collective. The subsets of this collective are events which we have deficient knowledge about on an individual level, although for the larger collective we have knowledge its aggregate behavior. Hence, probabilities can only be achieved through repeated trials of these subsets arriving at the established frequencies that define the probabilities. Crovelli (2009 argues that this is a mistaken approach, and that a subjective assessment of individual trials should be used instead. Bifurcating between the two concepts of risk and uncertainty, Crovelli first asserts that probability is the tool used to manage uncertain situations, and then attempts to rebuild a definition of probability theory with this in mind. We show that such an attempt has little to gain, and results in an indeterminate application of entrepreneurial forecasting to uncertain decisions—a process far-removed from any application of probability theory.

  19. Design of broadband single polarized antenna

    Science.gov (United States)

    Shin, Phoo Kho; Aziz, Mohamad Zoinol Abidin Abd.; Ahmad, Badrul Hisham; Ramli, Mohamad Hafize Bin; Fauzi, Noor Azamiah Md; Malek, Mohd Fareq Abd

    2015-05-01

    In practical wireless communication application, bandwidth enhancement becomes one of the major design considerations. At the same time, circular polarized (CP) antenna received much attention for the applications of modern wireless communication system when compared to linear polarized (LP) antenna. This is because CP antenna can reduce the multipath effect. Hence, broadband antenna with operating frequency at 2.4GHz for WLAN application is proposed. The proposed antenna is done by using L-probe amendment with rectangular patch. The rectangular patch and copper ground plane is separated with 10mm air gap. This approach is used to enhance the bandwidth and the gain of the proposed antenna. The bandwidth of the designed antenna is more than 200MHz which meet broadband application. The return loss for the antenna is below -10dB to achieved 90% matching efficiency. The position of L-probe feed is altered in order to obtained different polarizations. The broadband antenna had been designed and simulated by using Computer Simulation Technology (CST) software. In this paper, the comparison for single polarized antenna with the design of non-inverted patch and inverted patch is discussed. The characteristics of the S-parameter, axial ratio, gain, surface current for each designed antenna are analyzed.

  20. Performance of Single Friction Pendulum bearing for isolated buildings subjected to seismic actions in Vietnam

    Science.gov (United States)

    Nguyen, N. V.; Nguyen, C. H.; Hoang, H. P.; Huong, K. T.

    2018-04-01

    Using structural control technology in earthquake resistant design of buildings in Vietnam is very limited. In this paper, a performance evaluation of using Single Friction Pendulum (SFP) bearing for seismically isolated buildings with earthquake conditions in Vietnam is presented. A two-dimensional (2-D) model of the 5-storey building subjected to earthquakes is analyzed in time domain. Accordingly, the model is analyzed for 2 cases: with and without SFP bearing. The ground acceleration data is selected and scaled to suit the design acceleration in Hanoi followed by the Standard TCVN 9386:2012. It is shown that the seismically isolated buildings gets the performance objectives while achieving an 91% reduction in the base shear, a significant decrease in the inter-story drift and absolute acceleration of each story.

  1. Positive design : An introduction to design for subjective well-being

    NARCIS (Netherlands)

    Desmet, P.M.A.; Pohlmeyer, A.E.

    2013-01-01

    This paper addresses the question of how design can contribute to the happiness of individuals–to their subjective well-being. A framework for positive design is introduced that includes three main components of subjective well-being: pleasure, personal significance and virtue. Each component

  2. Pharmacokinetics of lansoprazole and its main metabolites after single intravenous doses in healthy Chinese subjects.

    Science.gov (United States)

    Zhang, Dan; Yang, Man; Liu, Man; Zhang, Yanan; Wang, Xiaolin; Xiao, Xue; Liu, Huichen

    2012-11-01

    The aim of the study was to evaluate the pharmacokinetics (PK) of lansoprazole (LPZ) and its main metabolites 5'-hydroxy lansoprazole (HLPZ) and lansoprazole sulphone (LPZS) after single intravenous (i.v.) doses of LPZ in healthy Chinese subjects, and the relationship between the cytochrome P450 (CYP) 2C19 phenotypes and the plasma concentrations of LPZS at the time-points in the elimination phase of LPZ. Twelve subjects were given lansoprazole by i.v. infusion. Blood samples were collected at designated time points up to 24 h. Plasma concentrations of LPZ, HLPZ and LPZS were quantified by a selective and sensitive liquid chromatography-tandem mass spectrometric (LC-MS/MS) method. After single i.v. doses of 15, 30 and 60 mg LPZ, C(max) and area under the plasma concentration-time curve (AUC(0-t)) of LPZ were 725 ± 151, 1480 ± 190, 3130 ± 480 µg · L(-1) and 1690 ± 1210, 3630 ± 2530, 8080 ± 4550 µg · h · L(-1), respectively. LPZ was generally well tolerated in healthy Chinese subjects, and displayed linear PK in the range of 15-60 mg. There were significant differences in the elimination of LPZ and the formation of LPZS between the single CYP2C19 poor metabolizer (PM) and the CYP2C19 extensive metabolizers (EM). The concentration of LPZS at the time-points in the elimination phase of LPZ could be monitored for CYP2C19 phenotyping. As a probe drug for CYP2C19 phenotyping, LPZ for injection might be more suitable than LPZ oral formulations.

  3. Self-Management Interventions on Students with Autism: A Meta-Analysis of Single-Subject Research

    Science.gov (United States)

    Carr, Monica E.; Moore, Dennis W.; Anderson, Angelika

    2014-01-01

    Self-management interventions aimed at skill acquisition and/or improving behavior of students diagnosed with autism spectrum disorders were examined. Twenty-three single-subject research design studies met inclusion criteria. Quality assessment of these studies was conducted using the What Works Clearinghouse guidelines, and treatment effect…

  4. Effects of listening to pleasant music on chronic unilateral neglect: a single-subject study.

    Science.gov (United States)

    Tsai, Pei-Luen; Chen, Mei-Ching; Huang, Yu-Ting; Lin, Keh-Chung

    2013-01-01

    Recent studies suggest that the positive emotion induced by pleasant music may improve cognitive functions. We used the single-subject design to study whether listening to preferred music may reduce unilateral neglect in two participants with post-stroke neglect. These participants were instructed to listen to their preferred music every day for 5 weeks, followed by 2 weeks of follow-up assessment. Outcome measures involved the Star Cancellation Test, the Line Bisection Test, and the visual exploration task. A combination of visual analysis and the two-standard-deviation band method was used for data analysis. Both participants showed significant intervention-related improvements on all outcome measures except the Line Bisection Test, on which one participant showed no improvement. The therapeutic effects were maintained during the follow-up phase. The findings suggest that positive emotion, evoked by preferred music, may be used to ameliorate unilateral neglect. Further research using controlled trials is warranted to validate the findings.

  5. Design of an Annular Disc Subject to Thermomechanical Loading

    Directory of Open Access Journals (Sweden)

    Sergei Alexandrov

    2012-01-01

    Full Text Available Two solutions to design a thin annular disc of variable thickness subject to thermomechanical loading are proposed. It is assumed that the thickness of the disc is everywhere sufficiently small for the stresses to be averaged through the thickness. The state of stress is plane. The initiation of plastic yielding is controlled by Mises yield criterion. The design criterion for one of the solutions proposed requires that the distribution of stresses is uniform over the entire disc. In this case there is a relation between optimal values of the loading parameters at the final stage. The specific shape of the disc corresponds to each pair of such parameters. The other solution is obtained under the additional requirement that the distribution of strains is uniform. This solution exists for the disc of constant thickness at specific values of the loading parameters.

  6. Subjectivity

    Directory of Open Access Journals (Sweden)

    Jesús Vega Encabo

    2015-11-01

    Full Text Available In this paper, I claim that subjectivity is a way of being that is constituted through a set of practices in which the self is subject to the dangers of fictionalizing and plotting her life and self-image. I examine some ways of becoming subject through narratives and through theatrical performance before others. Through these practices, a real and active subjectivity is revealed, capable of self-knowledge and self-transformation. 

  7. design, construction and measured performance of a single-stage

    African Journals Online (AJOL)

    2012-11-03

    Nov 3, 2012 ... Abstract. The design philosophy, construction and measured performances of a single stage, single entry centrifugal pump .... the tachometer spindle to be held against a recess in the motor shaft. The constructed centrifugal ...

  8. Program computes single-point failures in critical system designs

    Science.gov (United States)

    Brown, W. R.

    1967-01-01

    Computer program analyzes the designs of critical systems that will either prove the design is free of single-point failures or detect each member of the population of single-point failures inherent in a system design. This program should find application in the checkout of redundant circuits and digital systems.

  9. Pharmacokinetics of colistin methanesulfonate (CMS) in healthy Chinese subjects after single and multiple intravenous doses.

    Science.gov (United States)

    Zhao, Miao; Wu, Xiao-Jie; Fan, Ya-Xin; Zhang, Ying-Yuan; Guo, Bei-Ning; Yu, Ji-Cheng; Cao, Guo-Ying; Chen, Yuan-Cheng; Wu, Ju-Fang; Shi, Yao-Guo; Li, Jian; Zhang, Jing

    2018-05-01

    The high prevalence of extensively drug-resistant Gram-negative pathogens has forced clinicians to use colistin as a last-line therapy. Knowledge on the pharmacokinetics of colistin methanesulfonate (CMS), an inactive prodrug, and colistin has increased substantially; however, the pharmacokinetics in the Chinese population is still unknown due to lack of a CMS product in China. This study aimed to evaluate the pharmacokinetics of a new CMS product developed in China in order to optimise dosing regimens. A total of 24 healthy subjects (12 female, 12 male) were enrolled in single- and multiple-dose pharmacokinetic (PK) studies. Concentrations of CMS and formed colistin in plasma and urine were measured, and PK analysis was conducted using a non-compartmental approach. Following a single CMS dose [2.36 mg colistin base activity (CBA) per kg, 1 h infusion], peak concentrations (C max ) of CMS and formed colistin were 18.0 mg/L and 0.661 mg/L, respectively. The estimated half-life (t 1/2 ) of CMS and colistin were 1.38 h and 4.49 h, respectively. Approximately 62.5% of the CMS dose was excreted via urine within 24 h after dosing, whilst only 1.28% was present in the form of colistin. Following multiple CMS doses, colistin reached steady-state within 24 h; there was no accumulation of CMS, but colistin accumulated slightly (R AUC  = 1.33). This study provides the first PK data in the Chinese population and is essential for designing CMS dosing regimens for use in Chinese hospitals. The urinary PK data strongly support the use of intravenous CMS for serious urinary tract infections. Copyright © 2018 Elsevier B.V. and International Society of Chemotherapy. All rights reserved.

  10. Pharmacokinetic Effects of Antidrug Antibodies Occurring in Healthy Subjects After a Single Dose of Intravenous Infliximab.

    Science.gov (United States)

    Ehrenpreis, Eli D

    2017-12-01

    Infliximab pharmacokinetic studies have been performed in patients receiving chronic infliximab therapy. In these patients, infliximab antidrug antibodies (ADAs) increase infliximab clearance and decrease serum levels and drug efficacy. This study analyzed the pharmacokinetic effect of infliximab ADAs in healthy subjects receiving a single dose of intravenous infliximab. Data were obtained from a single-blind, parallel-group, single-dose study of healthy subjects receiving 5 mg/kg of intravenous SB2 (infliximab biosimilar), EU-sourced Remicade (EU-IFX) or US-sourced Remicade (US-IFX). Serum infliximab was measured at 1, 2, 3, 6, 12, 24, 48, and 72 h and at 5, 7, 14, 21, 28, 42, 56, and 70 days after administration. ADAs were measured pre-dose and at 29 and 71 days. Data from the first ten subjects randomized to each treatment arm were utilized for this study. A two-compartment model of the serum infliximab vs. time curve was developed using nonlinear regression. At 10 weeks, 11 subjects (37%) developed ADAs. ADAs were detected in four subjects after SB2, one subject after EU-IFX, and six subjects after US-IFX infusion. Of these, neutralizing antibodies occurred in one subject after SB2, in no subjects after EU-IFX, and in three subjects after US-IFX infusion. Infliximab clearance was increased in subjects with ADAs vs. those without ADAs (12.89 ± 2.69 vs. 9.90 ± 1.74 ml/h; p ADAs (282.4 ± 56.4 vs. 343.3 ± 61.9 h; p ADAs are common in healthy subjects after a single intravenous dose of infliximab and result in faster infliximab clearance, shorter elimination time, and lower serum infliximab levels. These data confirm that ADAs are common with biologic therapy and significantly impact the efficacy of these drugs.

  11. Temperature measurement and control system for transtibial prostheses: Single subject clinical evaluation.

    Science.gov (United States)

    Ghoseiri, Kamiar; Zheng, Yong Ping; Leung, Aaron K L; Rahgozar, Mehdi; Aminian, Gholamreza; Masoumi, Mehdi; Safari, Mohammad Reza

    2018-01-01

    The snug fit of a prosthetic socket over the residual limb can disturb thermal balance and put skin integrity in jeopardy by providing an unpleasant and infectious environment. The prototype of a temperature measurement and control (TM&C) system was previously introduced to resolve thermal problems related to prostheses. This study evaluates its clinical application in a setting with reversal, single subject design. The TM&C system was installed on a fabricated prosthetic socket of a man with unilateral transtibial amputation. Skin temperature of the residual limb without prosthesis at baseline and with prosthesis during rest and walking was evaluated. The thermal sense and thermal comfort of the participant were also evaluated. The results showed different skin temperature around the residual limb with a temperature decrease tendency from proximal to distal. The TM&C system decreased skin temperature rise after prosthesis wearing. The same situation occurred during walking, but the thermal power of the TM&C system was insufficient to overcome heat build-up in some regions of the residual limb. The participant reported no significant change of thermal sense and thermal comfort. Further investigations are warranted to examine thermography pattern of the residual limb, thermal sense, and thermal comfort in people with amputation.

  12. The Digital Design Process - Reflections on a Single Design Case

    NARCIS (Netherlands)

    Achten, H.H.; Joosen, G.; Dokonal, W.; Hirschberg, U.

    2003-01-01

    CAD tools are increasing their expressive and geometric power to enable a design process in which the computer model can be used throughout the whole design process for realizing the design. Such a process, in which other media such as physical scale models or drawings are no longer required by

  13. Analysis of an adhesively bonded single lap joint subjected to eccentric loading

    DEFF Research Database (Denmark)

    Anyfantis, Konstantinos; Tsouvalis, N. G.

    2013-01-01

    is benchmarking of computational tools. The test is based on a Single Lap Joint subjected to Eccentric Loading (SLJ-EL). The basic concept that lies behind this configuration is that the applied in-plane tensile load leads the adhesive layer to develop normal stresses, in-plane and out-of-plane shear stresses...

  14. Single Subject Prediction of Brain Disorders in Neuroimaging: Promises and Pitfalls

    Science.gov (United States)

    Arbabshirani, Mohammad R.; Plis, Sergey; Sui, Jing; Calhoun, Vince D.

    2016-01-01

    Neuroimaging-based single subject prediction of brain disorders has gained increasing attention in recent years. Using a variety of neuroimaging modalities such as structural, functional and diffusion MRI, along with machine learning techniques, hundreds of studies have been carried out for accurate classification of patients with heterogeneous mental and neurodegenerative disorders such as schizophrenia and Alzheimer's disease. More than 500 studies have been published during the past quarter century on single subject prediction focused on a multiple brain disorders. In the first part of this study, we provide a survey of more than 200 reports in this field with a focus on schizophrenia, mild cognitive impairment (MCI), Alzheimer's disease (AD), depressive disorders, autism spectrum disease (ASD) and attention-deficit hyperactivity disorder (ADHD). Detailed information about those studies such as sample size, type and number of extracted features and reported accuracy are summarized and discussed. To our knowledge, this is by far the most comprehensive review of neuroimaging-based single subject prediction of brain disorders. In the second part, we present our opinion on major pitfalls of those studies from a machine learning point of view. Common biases are discussed and suggestions are provided. Moreover, emerging trends such as decentralized data sharing, multimodal brain imaging, differential diagnosis, disease subtype classification and deep learning are also discussed. Based on this survey, there are extensive evidences showing the great potential of neuroimaging data for single subject prediction of various disorders. However, the main bottleneck of this exciting field is still the limited sample size, which could be potentially addressed by modern data sharing models such as the ones discussed in this paper. Emerging big data technologies and advanced data-intensive machine learning methodologies such as deep learning have coincided with an increasing need

  15. Media education in the subject of civic education (design worksheets)

    OpenAIRE

    ZIFČÁKOVÁ, Monika

    2012-01-01

    This bachelor thesis deals with Media education and its participation in subject called Citizenship education, which is taught in the form of worksheets at elementary school. The main aim of the thesis is to create worksheets to the subject of Media education. The worksheets should contribute to develop knowledge and skills in the field of Media education. Topics for worksheets are chosen in appropriate form, so they can be taught in Citizenship education at elementary school. The topics are ...

  16. Reflective Subjects in Kant and Architectural Design Education

    Science.gov (United States)

    Rawes, Peg

    2007-01-01

    In architectural design education, students develop drawing, conceptual, and critical skills which are informed by their ability to reflect upon the production of ideas in design processes and in the urban, environmental, social, historical, and cultural context that define architecture and the built environment. Reflective actions and thinking…

  17. Design of Brand Names of Medicines Considering Subjects' Preferences.

    Science.gov (United States)

    Pires, Carla Maria Batista Ferreira; Cavaco, Afonso

    2018-03-01

    Only recently, regulations on the names of medicines were developed. Regulations are mainly focused on avoiding the approval of medicine names that may be confusing to others. Furthermore, legal requirements do not include testing for human factors, such as potential users' preferences. To develop a set of new brand names of medicines, to determine subjects' preferred names, and to evaluate if the linguistic features of these names were related to subjects' preferences. Forty-six new names linguistically equivalent to the Portuguese brand names of medicines were developed. A panel of 13 postgraduates on linguistic studies were purposively enrolled. Participants were required to select and categorize the 6 most preferred names. From the 29 selected names: 62.1% ended in consonants, 65.5% contained at least one syllable of the CVC type, and 62.1% presented final stress. Considering these 3 linguistic features, there were statistically significant differences between the preferred and underpreferred names: χ 2 = 4.572, P = .032; χ 2 = 5.599, P = .018; and χ 2 = 4.572; P = .032, respectively. Some linguistic features of the evaluated names were related to subjects' preferences. Tests on subjects' preferences about the names of medicines may provide additional safety features addressed by the present regulations.

  18. Single- and multiple-dose pharmacokinetics, pharmacodynamics, and safety of apixaban in healthy Chinese subjects

    Directory of Open Access Journals (Sweden)

    Cui Y

    2013-12-01

    Full Text Available Yimin Cui,1 Yan Song,2 Jessie Wang,2 Zhigang Yu,2 Alan Schuster,2 Yu Chen Barrett,2 Charles Frost2 1Peking University First Hospital, Beijing, People's Republic of China; 2Bristol-Myers Squibb, Princeton, NJ, USA Background: The pharmacokinetics (PK, pharmacodynamics (PD, and safety of apixaban were assessed in healthy Chinese subjects in this randomized, placebo-controlled, double-blind, single-sequence, single- and multiple-dose study. Subjects and methods: Eighteen subjects 18–45 years of age were randomly assigned (2:1 ratio to receive apixaban or matched placebo. Subjects received a single 10 mg dose of apixaban or placebo on day 1, followed by 10 mg apixaban or placebo twice daily for 6 days (days 4–9. The PK and PD of apixaban were assessed by collecting plasma samples for 72 hours following the dose on day 1 and the morning dose on day 9, and measuring apixaban concentration and anti-Xa activity. Safety was assessed via physical examinations, vital sign measurements, electrocardiograms, and clinical laboratory evaluations. Results: PK analysis showed similar characteristics of apixaban after single and multiple doses, including a median time to maximum concentration of ~3 hours, mean elimination half-life of ~11 hours, and renal clearance of ~1.2 L/hour. The accumulation index was 1.7, consistent with twice-daily dosing and the observed elimination half-life. Single-dose data predict multiple-dose PK, therefore apixaban PK are time-independent. The relationship between anti-Xa activity and plasma apixaban concentrations appears to be linear. Apixaban was safe and well tolerated, with no bleeding-related adverse events reported. Conclusion: Apixaban was safe and well tolerated in healthy Chinese subjects. Apixaban PK and PD were predictable and consistent with findings from previous studies in Asian and non-Asian subjects. The administration of apixaban does not require any dose modification based on race. Keywords: apixaban, oral

  19. Pharmacokinetics of lansoprazole and its main metabolites after single and multiple intravenous doses in healthy Chinese subjects.

    Science.gov (United States)

    Zhang, Dan; Zhang, Yanan; Liu, Man; Wang, Xiaolin; Yang, Man; Han, Jing; Liu, Huichen

    2013-09-01

    The aim of the study was to evaluate and compare the pharmacokinetics of lansoprazole (LPZ) and its main metabolites, 5'-hydroxy lansoprazole (HLPZ) and lansoprazole sulfone (LPZS), after single and multiple intravenous (i.v.) doses of LPZ in healthy Chinese subjects. Twelve subjects (six males and six females) were given a single dose of LPZ by i.v. infusion on day 1, and multiple doses from day 2 to day 6. Blood samples were collected at designated time points for analysis of plasma concentrations of LPZ, HLPZ and LPZS by an LC-MS/MS method. LPZ was generally well tolerated in healthy Chinese subjects. After single and multiple i.v. doses of 30 mg LPZ, the C max values of LPZ, HLPZ and LPZS were 1490 ± 290 and 1450 ± 280, 175 ± 71 and 154 ± 56, and 51.3 ± 82.9 and 74.1 ± 158.7 ng/mL, with the AUC0-t values 3280 ± 2550 and 4260 ± 3880, 381 ± 128 and 389 ± 111, and 389 ± 1204 and 700 ± 2255 ng h/mL, respectively. The t 1/2 and CL values of LPZ after single and multiple i.v. doses were 1.48 ± 1.03 and 2.19 ± 1.03 h, and 11.67 ± 4.49 and 9.56 ± 4.08 L/h, respectively. Compared with the pharmacokinetics of LPZ after a single dose, t 1/2 increased markedly, CL decreased significantly and AUC increased by over 20 % after multiple doses. The results indicated that there was drug accumulation of LPZ after multiple i.v. doses, and there was no gender-related difference in pharmacokinetics of LPZ and its two metabolites.

  20. Security evaluation and design of structures subjected to blast loading

    OpenAIRE

    Pereira, João Miguel

    2014-01-01

    Tese de doutoramento em Engenharia Civil The work presented in this thesis was developed at the Department of Civil Engineering of University of Minho. This work involves experimental and numerical campaigns and intends to give a contribution for a better understanding of the effect of explosions. Blast loading is a subject of much actuality and considerable lack of expertise. Europe has never been so rich and safe, where the violent years of the first half of the 20th centu...

  1. Designing Cartoon as a Supplementary Material for English Structure Subject

    Science.gov (United States)

    Mina, Nurawati; Putranti, Sulistini Dwi

    2015-01-01

    Cartoon comes from an Italian word "Cartone" meaning a large paper. It is designed not only as the media to describe daily activities, but also to entertain, criticize, provoke, and even to teach people. A lot of studies have been conducted regarding the implementation of cartoon in classroom or outside classroom context. It is proven…

  2. A single dose of dark chocolate increases parasympathetic modulation and heart rate variability in healthy subjects

    Directory of Open Access Journals (Sweden)

    Ana Amélia Machado DUARTE

    Full Text Available ABSTRACT Objective: The aim of this study was to investigate the acute effect of a single dose of dark chocolate (70% cocoa on blood pressure and heart rate variability. Methods: Thirty-one healthy subjects (aged 18-25 years; both sexes were divided into two groups: 10 subjects in the white chocolate (7.4 g group and 21 in the dark chocolate (10 g group; measurements were performed at the university's physiology lab. An electrocardiogram measured the sympathovagal balance by spectral and symbolic analysis. Results: A single dose of dark chocolate significantly reduced systolic blood pressure and heart rate. After consuming 10 g of dark chocolate, significant increases were observed for heart rate variability, standard deviation of RR intervals standard deviation of all NN intervals, square root of the mean squared differences between adjacent normal RR intervals root mean square of successive differences, and an increase in the high frequency component in absolute values, representing the parasympathetic modulation. Conclusion: In conclusion the importance of our results lies in the magnitude of the response provoked by a single dose of cocoa. Just 10 g of cocoa triggered a significant increase in parasympathetic modulation and heart rate variability. These combined effects can potentially increase life expectancy because a reduction in heart rate variability is associated with several cardiovascular diseases and higher mortality.

  3. Learning Layouts for Single-Page Graphic Designs.

    Science.gov (United States)

    O'Donovan, Peter; Agarwala, Aseem; Hertzmann, Aaron

    2014-08-01

    This paper presents an approach for automatically creating graphic design layouts using a new energy-based model derived from design principles. The model includes several new algorithms for analyzing graphic designs, including the prediction of perceived importance, alignment detection, and hierarchical segmentation. Given the model, we use optimization to synthesize new layouts for a variety of single-page graphic designs. Model parameters are learned with Nonlinear Inverse Optimization (NIO) from a small number of example layouts. To demonstrate our approach, we show results for applications including generating design layouts in various styles, retargeting designs to new sizes, and improving existing designs. We also compare our automatic results with designs created using crowdsourcing and show that our approach performs slightly better than novice designers.

  4. Structural Design of Two-Cylinder Single Overhead Camshaft

    Science.gov (United States)

    Zhao, Yuxia; Zhang, Kangsheng; Di, Jiejian

    2018-01-01

    Due to the higher performance demand, the camshaft is the key driving part in the engine. Because it is eccentric circular section part, it is very difficult to design and manufacture this kind of axial parts. Take two-cylinder single overhead camshaft for an example, the entire process of camshaft design is analyzed. The practice has proved that the method has simple, flexible and efficient advantages, and it can greatly shorten the design of artificial computing time.

  5. The semantic variant of primary progressive aphasia: clinical and neuroimaging evidence in single subjects.

    Directory of Open Access Journals (Sweden)

    Leonardo Iaccarino

    Full Text Available We present a clinical-neuroimaging study in a series of patients with a clinical diagnosis of semantic variant of primary progressive aphasia (svPPA, with the aim to provide clinical-functional correlations of the cognitive and behavioral manifestations at the single-subject level.We performed neuropsychological investigations, 18F-FDG-PET single-subject and group analysis, with an optimized SPM voxel-based approach, and correlation analyses. A measurement of white matter integrity by means of diffusion tensor imaging (DTI was also available for a subgroup of patients.Cognitive assessment confirmed the presence of typical semantic memory deficits in all patients, with a relative sparing of executive, attentional, visuo-constructional, and episodic memory domains. 18F-FDG-PET showed a consistent pattern of cerebral hypometabolism across all patients, which correlated with performance in semantic memory tasks. In addition, a majority of patients also presented with behavioral disturbances associated with metabolic dysfunction in limbic structures. In a subgroup of cases the DTI analysis showed FA abnormalities in the inferior longitudinal and uncinate fasciculi.Each svPPA individual had functional derangement involving an extended, connected system within the left temporal lobe, a crucial part of the verbal semantic network, as well as an involvement of limbic structures. The latter was associated with behavioral manifestations and extended beyond the area of atrophy shown by CT scan.Single-subject 18F-FDG-PET analysis can account for both cognitive and behavioral alterations in svPPA. This provides useful support to the clinical diagnosis.

  6. Mild hallux valgus angle affects single-limb postural stability in asymptomatic subjects.

    Science.gov (United States)

    Çınar-Medeni, Özge; Atalay Guzel, Nevin; Basar, Selda

    2016-01-01

    Single-limb postural stability is a key component of lower extremity functional status. Factors affecting postural stability should be well defined to prevent injuries. The aim of this study was to investigate the effect of the hallux valgus angle on postural stability in asymptomatic subjects. A total of 19 subjects were included in the study. The hallux valgus angle and postural stability were assessed. Participants were assigned to two groups according to whether the hallux valgus angle was pathological or not. A hallux valgus angle greater than 15 degrees was accepted as pathological. The relationship between the hallux valgus angle and postural stability, and the differences in postural stability scores between the two groups were analyzed. Postural stability was assessed with a stabilometer. The test was performed with the eyes open. We found a significant correlation between the hallux valgus angle and mediolateral and overall stability index (r= 0.484, p= 0.036; r = 0.463, p= 0.046 respectively). Subjects with a pathological mild hallux valgus angle had greater stability index scores than normal subjects (phallux valgus angle has negative effects on postural stability as a forefoot deformity. This deformity should be taken into account for injury prevention strategies in pain-free younger adults.

  7. Enhancement of in vitro interleukin-2 production in normal subjects following a single spinal manipulative treatment

    Directory of Open Access Journals (Sweden)

    Harris Glen M

    2008-05-01

    Full Text Available Abstract Background Increasing evidence supports somato-visceral effects of manual therapies. We have previously demonstrated that a single spinal manipulative treatment (SMT accompanied by audible release has an inhibitory effect on the production of proinflammatory cytokines in asymptomatic subjects. The purpose of this study is to report on SMT-related changes in the production of the immunoregulatory cytokine interleukin 2 (IL-2 and to investigate whether such changes might differ with respect to the treatment approach related to the presence or absence of an audible release (joint cavitation. Methods Of 76 asymptomatic subjects, 29 received SMT with cavitation (SMT-C, 23 were treated with SMT without cavitation (SMT-NC and 24 comprised the venipuncture control (VC group. The SMT-C and SMT-NC subjects received a single, similar force high velocity low amplitude manipulation, in the upper thoracic spine. However, in SMT-NC subjects, positioning and line of drive were not conducive to cavitation. Blood and serum samples were obtained before and then at 20 and 120 min post-intervention. The production of IL-2 in peripheral blood mononuclear cell cultures was induced by activation for 48 hr with Staphylococcal protein A (SPA and, in parallel preparations, with the combination of phorbol ester (TPA and calcium ionophore. The levels of IL-2 in culture supernatants and serum were assessed by specific immunoassays. Results Compared with VC and their respective baselines, SPA-induced secretion of IL-2 increased significantly in cultures established from both SMT-C and SMT-NC subjects at 20 min post-intervention. At 2 hr post-treatment, significant elevation of IL-2 synthesis was still apparent in preparations from SMT-treated groups though it became somewhat attenuated in SMT-NC subjects. Conversely, IL-2 synthesis induced by TPA and calcium ionophore was unaltered by either type of SMT and was comparable to that in VC group at all time points. No

  8. A new microcavity design for single molecule detection

    International Nuclear Information System (INIS)

    Steiner, M.; Schleifenbaum, F.; Stupperich, C.; Failla, A.V.; Hartschuh, A.; Meixner, A.J.

    2006-01-01

    We present a new microcavity design which allows for efficient detection of single molecules by measuring the molecular fluorescence emission coupled into a resonant cavity mode. The Fabry-Perot-type microresonator consists of two silver mirrors separated by a thin polymer film doped with dye molecules in ultralow concenctration. By slightly tilting one of the mirrors different cavity lengths can be selected within the same sample. Locally, on a μm scale, the microcavity still acts as a planar Fabry-Perot resonator. Using scanning confocal fluorescence microscopy, single emitters on resonance with a single mode of the microresonator can be spatially addressed. Our microcavity is demonstrated to be well-suited for investigating the coupling mechanism between single quantum emitters and single modes of the electromagnetic field. The microcavity layout could be integrated in a lab-on-a-microchip design for ultrasensitive microfluidic analytics and can be considered as an important improvement for single photon sources based on single molecules operating at room temperature

  9. Gestalt Theory in Visual Screen Design — A New Look at an old subject

    OpenAIRE

    Chang, D.; Dooley, L.; Tuovinen, J. E

    2002-01-01

    Although often presented as a single basis for educational visual screen design, Gestalt theory is not a single small set of visual principles uniformly applied by all designers. In fact, it appears that instructional visual design literature often deals with only a small set of Gestalt laws. In this project Gestalt literature was consulted to distil the most relevant Gestalt laws for educational visual screen design. Eleven laws were identified. They deal with balance/symmetry, continuation,...

  10. Design of subjects training on reactor simulator and feasibility study - toward the empirical evaluation of interface design concept

    International Nuclear Information System (INIS)

    Yamaguchi, Y.; Furukawa, H.; Tanabe, F.

    1998-01-01

    On-going JAERI's project for empirical evaluation of the ecological interface design concept was first described. The empirical evaluation is planned to be proceeded through three consecutive steps; designing and actual implementation of the interface on reactor simulator, verification of the interface created, and the validation by the simulator experiment. For conducting the project, three different experimental resources are prerequisite, that are, data analysis method for identifying the operator's strategies, experimental facility including reactor simulator, and experimental subjects or subjects training method. Among the three experimental resources, subjects training method was recently designed and a simulator experiment was earned out in order to examine the feasibility of the designed training method. From the experiment and analysis of the experimental records, we could conclude that it is feasible that the experimental subjects having an appropriate technical basis can gain the sufficient competence for evaluation work of the interface design concept by using the training method designed. (author)

  11. A Theory-Driven Approach to Subject Design in Teacher Education

    Science.gov (United States)

    Zundans-Fraser, Lucia; Auhl, Greg

    2016-01-01

    The intent of this study was to examine how a theoretically-designed subject in an undergraduate teacher education course impacted on the learning and confidence of pre-service teachers in catering for the needs of students with diverse needs. The subject design utilised theoretical principles of self-organisation that were incorporated with the…

  12. Single-dose FTY720 pharmacokinetics, food effect, and pharmacological responses in healthy subjects

    Science.gov (United States)

    Kovarik, John M; Schmouder, Robert; Barilla, Denise; Wang, Yibin; Kraus, Gerolf

    2004-01-01

    Aims FTY720 is a sphingosine-1-phosphate receptor agonist that redirects lymphocytes from the circulation to lymph nodes without impairing lymphocyte function. It is being developed as an immunomodulator for the prevention of acute rejection after organ transplantation. This study was performed to provide guidance on administration with respect to meals and to measure pharmacologic responses in healthy subjects. Methods In this randomized, two-period, crossover study, 14 healthy subjects received placebo on day −1 of each period with baseline circadian measurements of lymphocyte count and heart rate. Subjects subsequently received a single 1 mg oral dose of FTY720 on day 1 under fasting conditions and after a high fat meal. Blood FTY720 concentrations, lymphocyte count, and supine heart rate were assessed over an 8 day period after each FTY720 dose. The effect of food on FTY720 pharmacokinetics was assessed by standard bioequivalence testing. Results Both the peak concentration (0.65 ± 0.17 vs 0.64 ± 0.18 ng ml−1) and total exposure (AUC 149 ± 65 vs 139 ± 43 ng ml−1 h) did not differ significantly between fasting and fed states, respectively. The corresponding fed/fasting ratios and 90% confidence intervals were 1.00 (0.86, 1.17) for Cmax and 0.98 (0.86, 1.11) for AUC. Under both treatment conditions peripheral blood lymphocyte count decreased from baseline by 38 ± 9% over the first 2 days postdose and then increased towards predose values over the subsequent week. Whereas a circadian rhythm in supine heart rate was preserved in the presence of FTY720, the heart rate vs time curve was shifted downwards by 10% over the first day postdose and then recovered to prestudy values by days 3–5 postdose. These changes were asymptomatic. Conclusions Single 1 mg doses of FTY720 were well tolerated in healthy subjects and elicited a moderate decrease in peripheral blood lymphocyte count and a transient decrease in heart rate consistent with its pharmacological

  13. Subjective and Objective Quality Assessment of Single-Channel Speech Separation Algorithms

    DEFF Research Database (Denmark)

    Mowlaee, Pejman; Saeidi, Rahim; Christensen, Mads Græsbøll

    2012-01-01

    Previous studies on performance evaluation of single-channel speech separation (SCSS) algorithms mostly focused on automatic speech recognition (ASR) accuracy as their performance measure. Assessing the separated signals by different metrics other than this has the benefit that the results...... are expected to carry on to other applications beyond ASR. In this paper, in addition to conventional speech quality metrics (PESQ and SNRloss), we also evaluate the separation systems output using different source separation metrics: blind source separation evaluation (BSS EVAL) and perceptual evaluation...... that PESQ and PEASS quality metrics predict well the subjective quality of separated signals obtained by the separation systems. From the results it is observed that the short-time objective intelligibility (STOI) measure predict the speech intelligibility results....

  14. A study on fatigue crack growth behavior subjected to a single tensile overload

    International Nuclear Information System (INIS)

    Lee, S.Y.; Liaw, P.K.; Choo, H.; Rogge, R.B.

    2011-01-01

    Neutron diffraction and electric potential experiments were carried out to investigate the growth behavior of a fatigue crack subjected to a single tensile overload. The specific objectives were to (i) probe the crack tip deformation and fracture behaviors under applied loads; (ii) examine the overload-induced transient crack growth micromechanism; (iii) validate the effective stress intensity factor range based on the crack closure approach as the fatigue crack tip driving force; and (iv) establish a quantitative relationship between the crack tip driving force and crack growth behavior. Immediately after a single tensile overload was introduced and then unloaded, the crack tip became blunt and enlarged compressive residual stresses in both magnitude and zone size were observed around the crack tip. The results show that the combined contributions of the overload-induced enlarged compressive residual stresses and crack tip blunting with secondary cracks are responsible for the observed changes in the crack opening load and the resultant post-overload transient crack growth behavior.

  15. Long-term functional, subjective and psychological results after single digit replantation.

    Science.gov (United States)

    Chen, Jing; Zhang, Ai Xian; Chen, Qing Zhong; Mu, Shuai; Tan, Jun

    2018-03-01

    The aim of this study was to analyse the long-term functional, subjective, and psychological results after single-digit replantation. Thirty cases of digital replantation (14 thumbs, 12 index fingers, 2 middle fingers, 1 ring finger, and 1 little finger) in 30 patients (7 females and 23 males) with a mean age of 44.2 years (20-65 years) were evaluated at the end of a mean follow-up time of 36 months (19-50 months). The active range of motion of joints, grip and pinch strength, cutaneous sensibility, upper-extremity functioning, and subjective satisfaction were determined using the Disability of Arm, Shoulder, and Hand (DASH) questionnaire and the Michigan Hand Outcomes questionnaire (MHQ). Psychological sequelae, including depression, anxiety, and posttraumatic stress disorder (PTSD), were assessed. A correlation analysis among variables was also performed. The mean score for the DASH questionnaire was 6.6 (range: 0-39.2). The symptom of cold intolerance occurred in 53% of the patients. Two patients were diagnosed with depression, and only one patient exhibited PTSD. The DASH score had a good statistical correlation with total grip strength, pinch grip strength, and static two-point discrimination (S-2PD) (P digit replantation are very low at long-term follow-up. Level IV, therapeutic study. Copyright © 2017 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  16. Experimental gingivitis induces systemic inflammatory markers in young healthy individuals: a single-subject interventional study.

    Science.gov (United States)

    Eberhard, Jörg; Grote, Karsten; Luchtefeld, Maren; Heuer, Wieland; Schuett, Harald; Divchev, Dimitar; Scherer, Ralph; Schmitz-Streit, Ruth; Langfeldt, Daniela; Stumpp, Nico; Staufenbiel, Ingmar; Schieffer, Bernhard; Stiesch, Meike

    2013-01-01

    We here investigated whether experimental gingivitis enhances systemic markers of inflammation which are also known as surrogate markers of atherosclerotic plaque development. Gingivitis is a low-level oral infection induced by bacterial deposits with a high prevalence within Western populations. A potential link between the more severe oral disease periodontitis and cardiovascular disease has already been shown. 37 non-smoking young volunteers with no inflammatory disease or any cardiovascular risk factors participated in this single-subject interventional study with an intra-individual control. Intentionally experimental oral inflammation was induced by the interruption of oral hygiene for 21 days, followed by a 21-days resolving phase after reinitiation of oral hygiene. Primary outcome measures at baseline, day 21 and 42 were concentrations of hsCRP, IL-6, and MCP-1, as well as adhesion capacity and oxLDL uptake of isolated blood monocytes. The partial cessation of oral hygiene procedures was followed by the significant increase of gingival bleeding (34.0%, Pgingivitis. Bacterial-induced gingival low-level inflammation induced a systemic increase in inflammatory markers. Dental hygiene almost completely reversed this experimental inflammatory process, suggesting that appropriate dental prophylaxis may also limit systemic markers of inflammation in subjects with natural gingivitis. International Clinical Trials Register Platform of the World Health Organization, registry number: DRKS00003366, URL: http://apps.who.int/trialsearch/Default.aspx.

  17. Effects of a single, oral 60 mg caffeine dose on attention in healthy adult subjects.

    Science.gov (United States)

    Wilhelmus, Micha Mm; Hay, Justin L; Zuiker, Rob Gja; Okkerse, Pieter; Perdrieu, Christelle; Sauser, Julien; Beaumont, Maurice; Schmitt, Jeroen; van Gerven, Joop Ma; Silber, Beata Y

    2017-02-01

    Caffeine induces positive effects on sustained attention, although studies assessing the acute effects of low caffeine dose (caffeine on sustained attention in tests lasting up to 45 minutes using 82 low or non-caffeine-consuming healthy male ( n=41) and female ( n=41) adults aged between 40 and 60 years. Vigilance was measured using Mackworth Clock test, Rapid Visual Information Processing Test, adaptive tracking test, saccadic eye movement and attention switch test. Effects on mood and fatigue were analysed using Bond and Lader and Caffeine Research visual analogue scales, and Samn-Perelli questionnaire. Saliva sampling was performed for both compliance and caffeine pharmacokinetic analysis. Administration of a 60 mg caffeine dose resulted in a significant improvement in sustained attention compared with the placebo. Also a significantly improved peak saccadic velocity and reaction time performance was found, and decreased error rate. Significantly increased feelings of alertness, contentment and overall mood after caffeine treatment compared with placebo were observed. This study demonstrated that in healthy adult subjects oral administration of a single 60 mg caffeine dose elicited a clear enhancement of sustained attention and alertness, measured both in multiple objective performances and in subjective scales.

  18. Long-term functional, subjective and psychological results after single digit replantation

    Directory of Open Access Journals (Sweden)

    Jing Chen

    2018-03-01

    Full Text Available Objective: The aim of this study was to analyse the long-term functional, subjective, and psychological results after single-digit replantation. Methods: Thirty cases of digital replantation (14 thumbs, 12 index fingers, 2 middle fingers, 1 ring finger, and 1 little finger in 30 patients (7 females and 23 males with a mean age of 44.2 years (20–65 years were evaluated at the end of a mean follow-up time of 36 months (19–50 months. The active range of motion of joints, grip and pinch strength, cutaneous sensibility, upper-extremity functioning, and subjective satisfaction were determined using the Disability of Arm, Shoulder, and Hand (DASH questionnaire and the Michigan Hand Outcomes questionnaire (MHQ. Psychological sequelae, including depression, anxiety, and posttraumatic stress disorder (PTSD, were assessed. A correlation analysis among variables was also performed. Results: The mean score for the DASH questionnaire was 6.6 (range: 0–39.2. The symptom of cold intolerance occurred in 53% of the patients. Two patients were diagnosed with depression, and only one patient exhibited PTSD. The DASH score had a good statistical correlation with total grip strength, pinch grip strength, and static two-point discrimination (S-2PD (P < 0.05. Several aspects of the MHQ were also statistically relevant to some or all of the three objective results. Furthermore, the grip strength showed significant correlation with DASH and most aspects of the MHQ in multivariate logistic regression analysis (P < 0.05. Conclusion: Total grip strength is the most important factor positively related to subjective outcomes. The incidence rates of psychological symptoms after digit replantation are very low at long-term follow-up. Level of evidence: Level IV, therapeutic study. Keywords: Digit Replantation, DASH score, Posttraumatic stress disorder

  19. EFFECTIVENESS OF ROCABADO'S TECHNIQUE FOR SUBJECTS WITH TEMPOROMANDIBULAR JOINT DYSFUNCTION - A SINGLE BLIND STUDY

    Directory of Open Access Journals (Sweden)

    Niha Siraj Mulla

    2015-02-01

    Full Text Available Background:A temporo-mandibular joint dysfunction or TMD is a group of conditions characterized by pain in the muscles of mastication, the temporo-mandiblar joint or both. Rocabado has described techniques includes the Rocabado’s manipulation and Rocabado’s exercises which have both been individually advocated for treatment of TMD. The purpose of study is to determine the effectiveness of Rocabado’s techniques on TMJ dysfunction symptoms, pain, TMJ Range of Motion (ROM and jaw functional limitation for subjects with temporo-mandibular joint dysfunction. Method: Pre to post test experimental study design, subjects with temporo-mandibular joint dysfunction randomized into two groups with 15 subjects into each group with total of 30 subjects in Study and control group, respectively. The study group received the Rocabado’s technique which consisted of Rocabado’s non-thrust TMJ manipulation and Rocabado’s exercises along with conventional TMJ exercises and the control group received only conventional TMJ exercises. The exercises were performed for 6 times per each session, six times in a day, one session under supervision and remaining five sessions by the subject at home for 6 days in a week for duration of 2 weeks. The outcome measurements such as VAS for pain, TMJ ROM, Fonseca’s questionnaire rating for TMJ dysfunction symptoms and jaw function limitation score (JFLS was measured before and after two weeks of intervention. Results: Comparative analysis, using Independent ‘t’ test and Mann Whitney U- test found that the means of VAS, TMJ ROM, Fonseca’s questionnaire and JFLS scores showed statistically significant difference (p <0.05 when the pre-intervention means and post-intervention means were compared between two groups. Conclusion: It is concluded that Rocabado’s technique found to have statistically and clinically significant added effect with conventional TMJ exercises shown greater percentage of improvements obtained

  20. The Single-Phase ProtoDUNE Technical Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Abi, B. [Univ. of Padova (Italy); et al.

    2017-06-21

    ProtoDUNE-SP is the single-phase DUNE Far Detector prototype that is under construction and will be operated at the CERN Neutrino Platform (NP) starting in 2018. ProtoDUNE-SP, a crucial part of the DUNE effort towards the construction of the first DUNE 10-kt fiducial mass far detector module (17 kt total LAr mass), is a significant experiment in its own right. With a total liquid argon (LAr) mass of 0.77 kt, it represents the largest monolithic single-phase LArTPC detector to be built to date. It's technical design is given in this report.

  1. Trajectory Design for a Single-String Impactor Concept

    Science.gov (United States)

    Dono Perez, Andres; Burton, Roland; Stupl, Jan; Mauro, David

    2017-01-01

    This paper introduces a trajectory design for a secondary spacecraft concept to augment science return in interplanetary missions. The concept consist of a single-string probe with a kinetic impactor on board that generates an artificial plume to perform in-situ sampling. The trajectory design was applied to a particular case study that samples ejecta particles from the Jovian moon Europa. Results were validated using statistical analysis. Details regarding the navigation, targeting and disposal challenges related to this concept are presented herein.

  2. Design of tracking photovoltaic systems with a single vertical axis

    Energy Technology Data Exchange (ETDEWEB)

    Lorenzo, E. [Ciudad Universitaria, Madrid (Spain). Instituto de Energeia Solar; Perez, M. [Pol Industrial La Nava, Naavarrsa (Spain). Alternativas Energeticas Solares; Ezpeleta, A. [Energia Hidroelectrica Navarra, Pamplona (Spain); Acedo, J. [Ingeteam SA, Pamplona (Spain)

    2002-07-01

    Solar tracking is used in large grid-connected photovoltaic plants to maximise solar radiation collection and, hence, to reduce the cost of delivered electricity. In particular, single vertical axis tracking, also called azimuth tracking, allows for energy gains up to 40%, compared with optimally tilted fully static arrays. This paper examines the theoretical aspects associated with the design of azimuth tracking, taking into account shadowing between different trackers and back-tracking features. Then, the practical design of the trackers installed at the 1.4 MW Tudela PV plant is presented and discussed. Finally, this tracking alternative is compared with the more conventional fully stationary approach. (author)

  3. Using virtual reality to distinguish subjects with multiple- but not single-domain amnestic mild cognitive impairment from normal elderly subjects.

    Science.gov (United States)

    Mohammadi, Alireza; Kargar, Mahmoud; Hesami, Ehsan

    2018-03-01

    Spatial disorientation is a hallmark of amnestic mild cognitive impairment (aMCI) and Alzheimer's disease. Our aim was to use virtual reality to determine the allocentric and egocentric memory deficits of subjects with single-domain aMCI (aMCIsd) and multiple-domain aMCI (aMCImd). For this purpose, we introduced an advanced virtual reality navigation task (VRNT) to distinguish these deficits in mild Alzheimer's disease (miAD), aMCIsd, and aMCImd. The VRNT performance of 110 subjects, including 20 with miAD, 30 with pure aMCIsd, 30 with pure aMCImd, and 30 cognitively normal controls was compared. Our newly developed VRNT consists of a virtual neighbourhood (allocentric memory) and virtual maze (egocentric memory). Verbal and visuospatial memory impairments were also examined with Rey Auditory-Verbal Learning Test and Rey-Osterrieth Complex Figure Test, respectively. We found that miAD and aMCImd subjects were impaired in both allocentric and egocentric memory, but aMCIsd subjects performed similarly to the normal controls on both tasks. The miAD, aMCImd, and aMCIsd subjects performed worse on finding the target or required more time in the virtual environment than the aMCImd, aMCIsd, and normal controls, respectively. Our findings indicated the aMCImd and miAD subjects, as well as the aMCIsd subjects, were more impaired in egocentric orientation than allocentric orientation. We concluded that VRNT can distinguish aMCImd subjects, but not aMCIsd subjects, from normal elderly subjects. The VRNT, along with the Rey Auditory-Verbal Learning Test and Rey-Osterrieth Complex Figure Test, can be used as a valid diagnostic tool for properly distinguishing different forms of aMCI. © 2018 Japanese Psychogeriatric Society.

  4. Optimal Multitrial Prediction Combination and Subject-Specific Adaptation for Minimal Training Brain Switch Designs

    NARCIS (Netherlands)

    Spyrou, L.; Blokland, Y.M.; Farquhar, J.D.R.; Bruhn, J.

    2016-01-01

    Brain-Computer Interface (BCI) systems are traditionally designed by taking into account user-specific data to enable practical use. More recently, subject independent (SI) classification algorithms have been developed which bypass the subject specific adaptation and enable rapid use of the system.

  5. Optimal multitrial prediction combination and subject-specific adaptation for minimal training brain switch designs

    NARCIS (Netherlands)

    Spyrou, L.; Blokland, Y.M.; Farquhar, J.D.R.; Bruhn, J.

    2016-01-01

    Brain-Computer Interface systems are traditionally designed by taking into account user-specific data to enable practical use. More recently, subject independent (SI) classification algorithms have been developed which bypass the subject specific adaptation and enable rapid use of the system. A

  6. Role of the DGAT gene C79T single-nucleotide polymorphism in French obese subjects.

    Science.gov (United States)

    Coudreau, Sylvie Kipfer; Tounian, Patrick; Bonhomme, Geneviève; Froguel, Philippe; Girardet, Jean-Philippe; Guy-Grand, Bernard; Basdevant, Arnaud; Clément, Karine

    2003-10-01

    Acyl-coenzyme A, diacylglycerol acyltransferase (DGAT), is a key enzyme involved in adipose-cell triglyceride storage. A 79-bp T-to-C single-nucleotide polymorphism (SNP) on the 3' region of the DGAT transcriptional site has been reported to increase promoter activity and is associated with higher BMI in Turkish women. To validate the possible role of this genetic variant in obesity, as well as the variant's possible cellular-functional significance, we performed an association study between the T79C change and several obesity-related phenotypes in 1357 obese French adults and children. The prevalence of the T79C SNP was similar between obese adults and children when each group was compared with the controls. (CC genotype carrier frequencies were 0.25 to 0.29 in the obese groups and 0.21 in controls; p > 0.05.) In each of the obese adult and child groups studied, the T79C variant was not found to be associated with any of the obesity-related phenotypes tested. Although the T79C SNP of the DGAT gene was studied in several groups of white subjects, the association between this SNP and obesity-related phenotypes, previously described, was not confirmed in our population.

  7. Brain Single Photon Emission Computed Tomography in Anosmic Subjects Ater Closed Head Trauma

    Directory of Open Access Journals (Sweden)

    Roozbeh Banan

    2011-01-01

    Full Text Available Anosmia following head trauma is relatively common and in many cases is persistent and irreversible. The ability to objectively measure such a decline in smelling, for both clinical and medicolegal goals, is very important. The aim of this study was to find results of brain Single Photon Emission Computed Tomography (SPECT in anosmic subjects after closed head trauma. This case-control cross sectional study was conducted in a tertiary referral University Hospital. The brain perfusion state of nineteen anosmic patients and thirteen normal controls was evaluated by means of the SPECT with 99mtc- ECD infusion- before and after olfactory stimulation. The orbitofrontal lobe of the brain was assumed as the region of interest and changes in perfusion of this area before and after the stimulations were compared in two groups. The mean of brain perfusion in controls before and after the stimulation was 8.26% ± 0.19% and 9.89% ± 0.54%, respectively (P < 0.0001. Among patients group, these quantities were 7.97% ± 1.05% and 8.49% ± 1.5%, respectively (P < 0.004. The difference between all the measures in cases and controls were statistically significant (P < 0.0001. There were no differences in age and sex between two groups. The brain SPECT is an objective technique suitable for evaluating anosmia following the head trauma and it may be used with other diagnostic modalities

  8. Design of single piece sabot for a single stage gas gun

    Science.gov (United States)

    Vemparala, Vignesh; Mathew, Arun Tom; Rao Koka, Tirumala

    2017-11-01

    Single piece sabot is a vital part in single stage gas guns for impact testing in aerospace industries. Depending on the type of projectile used the design of sabot varies to accommodate the testing equipment. The velocity of the projectile exiting the barrel is dependent on the material and shape of the sabot used. The material selected for the design of sabot is rigid polyurethane foam, due to their low elastic modulus and low density. Two samples of rigid PU foam is taken and tests are performed to get their exact material properties. These properties are incorporated in numerical simulation to determine the best fit for practical use. Since the PU foams has a wide range of porosity which plays a prominent role in deciding the exit velocity and accuracy of the projectile coming out of the barrel. By optimisation, to the best suitable material sample can be determined.

  9. Pen needle design influences ease of insertion, pain, and skin trauma in subjects with type 2 diabetes

    DEFF Research Database (Denmark)

    Præstmark, Kezia A; Jensen, Morten L; Berg Madsen, Nils

    2016-01-01

    subject and in random order. Penetration force (PF) through the skin, pain perception on 100 mm visual analog scale, and change in skin blood perfusion (SBP) were quantified after the insertions. RESULTS: Needle diameter was positively related to PF and SBP (ptrend relation...... of insertion, pain and skin trauma. RESEARCH DESIGN AND METHODS: 30 subjects with injection-treated type 2 diabetes and body mass index 25-35 kg/m(2) were included in the single-blinded study. Each subject received abdominal insertions with 18 different types of needles. All needles were tested twice per....... Lack of needle lubrication and small 'needle hooks' increased PF and SBP (pskin and in polyurethane rubber were linearly related, and pain outcome...

  10. Single pressure vessel (SPV) nickel-hydrogen battery design

    Energy Technology Data Exchange (ETDEWEB)

    Coates, D.; Grindstaff, B.; Fox, C. [Eagle-Picher Industries, Inc., Joplin, MO (United States)

    1995-07-01

    Single pressure vessel (SPV) technology combines an entire multi-cell nickel-hydrogen (NiH{sub 2}) space battery within a single pressure vessel. SPV technology has been developed to improve the performance (volume/mass) of the NiH{sub 2} system at the battery level and ultimately to reduce overall battery cost and increase system reliability. Three distinct SPV technologies are currently under development and in production. Eagle-Picher has license to the COMSAT Laboratories technology, as well as internally developed independent SPV technology. A third technology resulted from the acquisition of Johnson Controls NiH{sub 2} battery assets in June, 1994. SPV batteries are currently being produced in 25 ampere-hour (Ah), 35 Ah and 50 Ah configurations. The battery designs have an overall outside diameter of 10 inches (25.4 centimeters).

  11. SCREAMER: a single-line pulsed-power design tool

    International Nuclear Information System (INIS)

    Kiefer, M.L.; Widner, M.M.

    1985-01-01

    SCREAMER is a special purpose circuit code developed as a design tool for single module accelerators. It is fast, accurate, flexible, and user-friendly. Its development was motivated by the excessive costs and long turn-around times incurred when using the SCEPTRE circuit analysis code to perform simulations of circuits with large numbers of nodes and with nonlinear components. Comparable simulations between SCREAMER running on a VAX 11/780 and SCEPTRE running on a CRAY-1S show that turn-around times and costs can be two orders of magnitude lower when using SCREAMER

  12. SCREAMER - A single-line pulsed-power design tool

    International Nuclear Information System (INIS)

    Kiefer, M.L.; Widner, M.M.

    1985-01-01

    SCREAMER is a special purpose circuit code developed as a design tool for single module accelerators. it is fast, accurate, flexible, and user-friendly. Its development was motivated by the excessive costs and long turn-around times incurred when using the SCEPTRE circuit analysis code to perform simulations of circuits with large numbers of modes and with nonlinear components. Comparable simulations between SCREAMER running on a VAX 11/780 and SCEPTRE running on a CRAY-1S show that turn-around times and costs can be two orders of magnitude lower when using SCREAMER

  13. Mechanism Design for Single Leader Stackelberg Problems and Application to Procurement Auction Design

    OpenAIRE

    Garg, Dinesh; Narahari, Y

    2008-01-01

    In this paper, we focus on mechanism design for single leader Stackelberg problems, which are a special case of hierarchical decision making problems in which a distinguished agent, known as the leader, makes the first move and this action is followed by the actions of the remaining agents, which are known as the followers. These problems are also known as single leader rest follower (SLRF) problems. There are many examples of such problems in the areas of electronic commerce, supply chain ma...

  14. POBE: A Computer Program for Optimal Design of Multi-Subject Blocked fMRI Experiments

    Directory of Open Access Journals (Sweden)

    Bärbel Maus

    2014-01-01

    Full Text Available For functional magnetic resonance imaging (fMRI studies, researchers can use multi-subject blocked designs to identify active brain regions for a certain stimulus type of interest. Before performing such an experiment, careful planning is necessary to obtain efficient stimulus effect estimators within the available financial resources. The optimal number of subjects and the optimal scanning time for a multi-subject blocked design with fixed experimental costs can be determined using optimal design methods. In this paper, the user-friendly computer program POBE 1.2 (program for optimal design of blocked experiments, version 1.2 is presented. POBE provides a graphical user interface for fMRI researchers to easily and efficiently design their experiments. The computer program POBE calculates the optimal number of subjects and the optimal scanning time for user specified experimental factors and model parameters so that the statistical efficiency is maximised for a given study budget. POBE can also be used to determine the minimum budget for a given power. Furthermore, a maximin design can be determined as efficient design for a possible range of values for the unknown model parameters. In this paper, the computer program is described and illustrated with typical experimental factors for a blocked fMRI experiment.

  15. Towards sustainable design for single-use medical devices.

    Science.gov (United States)

    Hanson, Jacob J; Hitchcock, Robert W

    2009-01-01

    Despite their sophistication and value, single-use medical devices have become commodity items in the developed world. Cheap raw materials along with large scale manufacturing and distribution processes have combined to make many medical devices more expensive to resterilize, package and restock than to simply discard. This practice is not sustainable or scalable on a global basis. As the petrochemicals that provide raw materials become more expensive and the global reach of these devices continues into rapidly developing economies, there is a need for device designs that take into account the total life-cycle of these products, minimize the amount of non-renewable materials consumed and consider alternative hybrid reusable / disposable approaches. In this paper, we describe a methodology to perform life cycle and functional analyses to create additional design requirements for medical devices. These types of sustainable approaches can move the medical device industry even closer to the "triple bottom line"--people, planet, profit.

  16. Optimization design of energy deposition on single expansion ramp nozzle

    Science.gov (United States)

    Ju, Shengjun; Yan, Chao; Wang, Xiaoyong; Qin, Yupei; Ye, Zhifei

    2017-11-01

    Optimization design has been widely used in the aerodynamic design process of scramjets. The single expansion ramp nozzle is an important component for scramjets to produces most of thrust force. A new concept of increasing the aerodynamics of the scramjet nozzle with energy deposition is presented. The essence of the method is to create a heated region in the inner flow field of the scramjet nozzle. In the current study, the two-dimensional coupled implicit compressible Reynolds Averaged Navier-Stokes and Menter's shear stress transport turbulence model have been applied to numerically simulate the flow fields of the single expansion ramp nozzle with and without energy deposition. The numerical results show that the proposal of energy deposition can be an effective method to increase force characteristics of the scramjet nozzle, the thrust coefficient CT increase by 6.94% and lift coefficient CN decrease by 26.89%. Further, the non-dominated sorting genetic algorithm coupled with the Radial Basis Function neural network surrogate model has been employed to determine optimum location and density of the energy deposition. The thrust coefficient CT and lift coefficient CN are selected as objective functions, and the sampling points are obtained numerically by using a Latin hypercube design method. The optimized thrust coefficient CT further increase by 1.94%, meanwhile, the optimized lift coefficient CN further decrease by 15.02% respectively. At the same time, the optimized performances are in good and reasonable agreement with the numerical predictions. The findings suggest that scramjet nozzle design and performance can benefit from the application of energy deposition.

  17. Evaluation of the single radiosensitivity in patients subjected to medical exposure that show severe skin reactions

    International Nuclear Information System (INIS)

    Di Giorgio, M.; Vallerga, M.B.; Portas, M.; Perez, M.R.

    2006-01-01

    The Burnt Hospital of the Buenos Aires City Government (HQGCBA) it is a hospital of reference of the Net of Medical Responses in Radiological Emergencies of the Argentine Republic. In the mark of an agreement among the HQGCBA and the Authority Regulatory Nuclear (ARN), it is in execution a study protocol for the one boarding diagnoses and therapeutic of radioinduced cutaneous leisure. They exist individual variations that can condition the response to the ionizing radiations (IR), so much in accidental exposures as having programmed (radiotherapy, radiology interventionist). In this context, the individual radiosensitivity is evaluated in the patients signed up in this protocol that presented sharp or late cutaneous reactions, with grades of severity 3-4 (approaches EORTC/RTOG). The capacity of repair of the DNA was evaluated in outlying blood lymphocytes irradiated in vitro (2 Gy, gamma of Co-60) by means of the micronucleus techniques and comet essay in alkaline conditions. In this work two cases in those that is applied this study protocol, the therapeutic answer and its correlate with the discoveries of the radiosensitivity tests is presented. Case 1: patient of feminine sex, subjected to external radiotherapy by a breast infiltrating ductal carcinoma; developed sharp cutaneous radiotoxicity grade 3 (confluent humid epithelitis) that motivate the interruption of the treatment. Case 2: patient of masculine sex, subjected to a coronary angioplasty (interventionist radiology); developed late cutaneous radiotoxicity grade 4 (ulceration in dorsal region). Both patients were treated with topical trolamine associated to systemic administration of pentoxiphiline and antioxidants. The therapeutic answer is evaluated by means of clinical pursuit, photographic serial register and complementary exams (thermography and ultrasonography of high frequency). In the case 1 the answer was very favorable, with precocious local improvement and complete remission of symptoms and

  18. Computing tools for implementing standards for single-case designs.

    Science.gov (United States)

    Chen, Li-Ting; Peng, Chao-Ying Joanne; Chen, Ming-E

    2015-11-01

    In the single-case design (SCD) literature, five sets of standards have been formulated and distinguished: design standards, assessment standards, analysis standards, reporting standards, and research synthesis standards. This article reviews computing tools that can assist researchers and practitioners in meeting the analysis standards recommended by the What Works Clearinghouse: Procedures and Standards Handbook-the WWC standards. These tools consist of specialized web-based calculators or downloadable software for SCD data, and algorithms or programs written in Excel, SAS procedures, SPSS commands/Macros, or the R programming language. We aligned these tools with the WWC standards and evaluated them for accuracy and treatment of missing data, using two published data sets. All tools were tested to be accurate. When missing data were present, most tools either gave an error message or conducted analysis based on the available data. Only one program used a single imputation method. This article concludes with suggestions for an inclusive computing tool or environment, additional research on the treatment of missing data, and reasonable and flexible interpretations of the WWC standards. © The Author(s) 2015.

  19. Robustness of crossover trials against subject drop-out - Examples of perpetually connected designs.

    Science.gov (United States)

    Godolphin, P J; Godolphin, E J

    2017-01-01

    When performing a repeated measures experiment, such as a clinical trial, there is a risk of subject drop-out during the experiment. If one or more subjects leave the study prematurely, a situation could arise where the eventual design is disconnected, implying that very few treatment contrasts for both direct effects and carryover effects are estimable. This paper aims to identify experimental conditions where this problem with the eventual design can be avoided. It is shown that in the class of uniformly balanced repeated measurement designs consisting of two or more Latin squares, there are planned designs with the following useful property. Provided that all subjects have completed the first two periods of study, such a design will not be replaced by a disconnected eventual design due to drop-out, irrespective of the type of drop-out behaviour that may occur. Designs with this property are referred to as perpetually connected. These experimental conditions are identified and examined in the paper and an example of at least one perpetually connected uniformly balanced repeated measurement design is given in each case. The results improve upon previous contributions in the literature that have been confined largely to cases in which drop-out occurs only in the final periods of study.

  20. Effects of Singapore's Model Method on Elementary Student Problem Solving Performance: Single Subject Research

    Science.gov (United States)

    Mahoney, Kevin

    2012-01-01

    This research investigation examined the effects of Singapore's Model Method, also known as "model drawing" or "bar modeling" on the word problem-solving performance of American third and fourth grade students. Employing a single-case design, a researcher-designed teaching intervention was delivered to a child in third…

  1. Single-subject structural networks with closed-form rotation invariant matching mprove power in developmental studies of the cortex.

    Science.gov (United States)

    Kandel, Benjamin M; Wang, Danny J J; Gee, James C; Avants, Brian B

    2014-01-01

    Although much attention has recently been focused on single-subject functional networks, using methods such as resting-state functional MRI, methods for constructing single-subject structural networks are in their infancy. Single-subject cortical networks aim to describe the self-similarity across the cortical structure, possibly signifying convergent developmental pathways. Previous methods for constructing single-subject cortical networks have used patch-based correlations and distance metrics based on curvature and thickness. We present here a method for constructing similarity-based cortical structural networks that utilizes a rotation-invariant representation of structure. The resulting graph metrics are closely linked to age and indicate an increasing degree of closeness throughout development in nearly all brain regions, perhaps corresponding to a more regular structure as the brain matures. The derived graph metrics demonstrate a four-fold increase in power for detecting age as compared to cortical thickness. This proof of concept study indicates that the proposed metric may be useful in identifying biologically relevant cortical patterns.

  2. A Field-Tested Task Analysis for Creating Single-Subject Graphs Using Microsoft[R] Office Excel

    Science.gov (United States)

    Lo, Ya-yu; Konrad, Moira

    2007-01-01

    Creating single-subject (SS) graphs is challenging for many researchers and practitioners because it is a complex task with many steps. Although several authors have introduced guidelines for creating SS graphs, many users continue to experience frustration. The purpose of this article is to minimize these frustrations by providing a field-tested…

  3. Stimulus-Dominance Effects and Lateral Asymmetries for Language in Normal Subjects and in Patients with a Single Functional Hemisphere

    Science.gov (United States)

    Di Stefano, Marirosa; Marano, Elena; Viti, Marzia

    2004-01-01

    The assessment of language laterality by the dichotic fused-words test may be impaired by interference effects revealed by the dominant report of one member of the stimuli-pair. Stimulus-dominance and ear asymmetry were evaluated in normal population (48 subjects of both sex and handedness) and in 2 patients with a single functional hemisphere.…

  4. Picture Exchange Communication System with Individuals with Developmental Disabilities: A Meta-Analysis of Single Subject Studies

    Science.gov (United States)

    Hart, Stephanie L.; Banda, Devender R.

    2010-01-01

    Picture Exchange Communication System (PECS) is a picture-based communication strategy used to teach communication skills to persons with developmental disabilities including autism. This article systematically reviews 13 published single-subject studies to examine the effectiveness of PECS, the effects of PECS on speech and problem behaviors,…

  5. An Evaluation of a Computer-Based Training on the Visual Analysis of Single-Subject Data

    Science.gov (United States)

    Snyder, Katie

    2013-01-01

    Visual analysis is the primary method of analyzing data in single-subject methodology, which is the predominant research method used in the fields of applied behavior analysis and special education. Previous research on the reliability of visual analysis suggests that judges often disagree about what constitutes an intervention effect. Considering…

  6. Pen needle design influences ease of insertion, pain, and skin trauma in subjects with type 2 diabetes.

    Science.gov (United States)

    Præstmark, Kezia A; Jensen, Morten L; Madsen, Nils B; Kildegaard, Jonas; Stallknecht, Bente M

    2016-01-01

    Pen needles used for subcutaneous injections have gradually become shorter, thinner and more thin walled, and thereby less robust to patient reuse. Thus, different needle sizes, alternative tip designs and needles resembling reuse were tested to explore how needle design influences ease of insertion, pain and skin trauma. 30 subjects with injection-treated type 2 diabetes and body mass index 25-35 kg/m 2 were included in the single-blinded study. Each subject received abdominal insertions with 18 different types of needles. All needles were tested twice per subject and in random order. Penetration force (PF) through the skin, pain perception on 100 mm visual analog scale, and change in skin blood perfusion (SBP) were quantified after the insertions. Needle diameter was positively related to PF and SBP (ptrend relation. Lack of needle lubrication and small 'needle hooks' increased PF and SBP (pskin and in polyurethane rubber were linearly related, and pain outcome was dependent of SBP increase. The shape and design of a needle and the needle tip affect ease of insertion, pain and skin trauma. Relations are seen across different data acquisition methods and across species, enabling needle performance testing outside of clinical trials. NCT02531776; results.

  7. Single- and Multiple-Dose Study To Determine the Safety, Tolerability, Pharmacokinetics, and Food Effect of Oral MRX-I versus Linezolid in Healthy Adult Subjects.

    Science.gov (United States)

    Eckburg, Paul B; Ge, Yigong; Hafkin, Barry

    2017-04-01

    A multipart phase 1 study was conducted to determine the safety, tolerability, pharmacokinetics, and food effect of the novel oral oxazolidinone, MRX-I, in healthy adults, as well as the tolerability of longer-term exposure of both oral MRX-I and linezolid. Thirty subjects in part 1 received single ascending doses of MRX-I or placebo under fasting or fed condition in a double-blind crossover design. Twelve subjects in part 2 received MRX-I at 800 mg every 12 h (q12h) for 14 days in a double-blind, placebo-controlled design. In part 3, 24 subjects were randomized to receive 28 days of MRX-I at 800 mg q12h or oral linezolid at 600 mg q12h for 28 days in a double-blind, double-dummy design. Oral MRX-I was associated with a greater bioavailability and exposure when administered with food, and minimal accumulation of MRX-I occurred after multiple-dose administration. Oral MRX-I was well tolerated at single doses of up to 1,200 and 800 mg q12h for up to 28 days; all adverse events were mild to moderate in severity, and there was no drug discontinuation due to adverse events. These data support further clinical development of oral MRX-I in the treatment of resistant Gram-positive bacterial infections. Copyright © 2017 American Society for Microbiology.

  8. Dealing with subjectivity in early product design phase: a systematic approch to exploit QFD potentials

    NARCIS (Netherlands)

    Raharjo, H.; Brombacher, A.C.; Xie, M.

    2008-01-01

    Quality Function Deployment (QFD), as a customer-driven tool, is generally used in the early phase of new or improved products/services design process, and therefore most of the input parameters are highly subjective in nature. The five major input components of the QFD, which are laid in the House

  9. A Framework for Control System Design Subject to Average Data-Rate Constraints

    DEFF Research Database (Denmark)

    Silva, Eduardo; Derpich, Milan; Østergaard, Jan

    2011-01-01

    This paper studies discrete-time control systems subject to average data-rate limits. We focus on a situation where a noisy linear system has been designed assuming transparent feedback and, due to implementation constraints, a source-coding scheme (with unity signal transfer function) has to be ...

  10. Usability Testing, User-Centered Design, and LibGuides Subject Guides: A Case Study

    Science.gov (United States)

    Sonsteby, Alec; DeJonghe, Jennifer

    2013-01-01

    Usability testing has become a routine way for many libraries to ensure that their Web presence is user-friendly and accessible. At the same time, popular subject guide creation systems, such as LibGuides, decentralize Web content creation and put authorship into the hands of librarians who may not be trained in user-centered design principles. At…

  11. Single Pass Stripline Beam Position Monitor Design, Fabrication and Commissioning

    Directory of Open Access Journals (Sweden)

    McKinlay J.

    2012-10-01

    Full Text Available To monitor the position of the electron beam during transport from the Booster Synchrotron to the Storage Ring at the Australian Synchrotron, a stripline Beam Position Monitor (BPM has been designed, fabricated and installed in-house. The design was based on an existing stripline in the Booster and modified for the transfer line with a particular emphasis on ensuring the line impedance is properly matched to the detector system. The initial bench tests of a prototype stripline showed that the fabrication of the four individual striplines in the BPM was made precisely, each with a measured standing wave ratio (SWR of 1.8 at 500 MHz. Further optimization for impedance matching will be done for new stripline BPMs. The linearity and gain factor was measured with the detector system. The detector system that digitizes the signals is an Instrumentation Technologies Brilliance Single Pass [1]. The results show an error of 1 mm at an offset (from the electrical centre of 10 mm when a linear gain factor is assumed and an RMS noise of ~150 um that decreases to < 10 um with increasing signal intensity. The results were under our requirements for the transport line. The commissioning results of the stripline will also be presented showing a strong signal for an electron beam with an estimated integrated charge of ~50 nC with a position stability of 28 um (horizontal and 75 um (vertical.

  12. Single Pass Stripline Beam Position Monitor Design, Fabrication and Commissioning

    Science.gov (United States)

    Tan, Y.-R. E.; Wang, D.; Van Garderen, E.; McKinlay, J.

    2012-10-01

    To monitor the position of the electron beam during transport from the Booster Synchrotron to the Storage Ring at the Australian Synchrotron, a stripline Beam Position Monitor (BPM) has been designed, fabricated and installed in-house. The design was based on an existing stripline in the Booster and modified for the transfer line with a particular emphasis on ensuring the line impedance is properly matched to the detector system. The initial bench tests of a prototype stripline showed that the fabrication of the four individual striplines in the BPM was made precisely, each with a measured standing wave ratio (SWR) of 1.8 at 500 MHz. Further optimization for impedance matching will be done for new stripline BPMs. The linearity and gain factor was measured with the detector system. The detector system that digitizes the signals is an Instrumentation Technologies Brilliance Single Pass [1]. The results show an error of 1 mm at an offset (from the electrical centre) of 10 mm when a linear gain factor is assumed and an RMS noise of ~150 um that decreases to < 10 um with increasing signal intensity. The results were under our requirements for the transport line. The commissioning results of the stripline will also be presented showing a strong signal for an electron beam with an estimated integrated charge of ~50 nC with a position stability of 28 um (horizontal) and 75 um (vertical).

  13. Pharmacokinetics and Safety of Intravenous Murepavadin Infusion in Healthy Adult Subjects Administered Single and Multiple Ascending Doses.

    Science.gov (United States)

    Wach, Achim; Dembowsky, Klaus; Dale, Glenn E

    2018-04-01

    Murepavadin is the first in class of the outer membrane protein-targeting antibiotics (OMPTA) and a pathogen-specific peptidomimetic antibacterial with a novel, nonlytic mechanism of action targeting Pseudomonas aeruginosa Murepavadin is being developed for the treatment of hospital-acquired bacterial pneumonia (HABP) and ventilator-associated bacterial pneumonia (VABP). The pharmacokinetics (PK) and safety of single and multiple doses of murepavadin were investigated in healthy male subjects. Part A of the study was a double-blind, randomized, placebo-controlled, single-ascending-dose investigation in 10 sequential cohorts where each cohort comprised 6 healthy male subjects; 4 subjects were randomized to murepavadin, and 2 subjects were randomized to placebo. Part B was a double-blind, randomized, placebo-controlled, multiple-ascending-dose investigation in 3 sequential cohorts. After a single dose of murepavadin, the geometric mean half-life (2.52 to 5.30 h), the total clearance (80.1 to 114 ml/h/kg), and the volume of distribution (415 to 724 ml/kg) were consistent across dose levels. The pharmacokinetics of the dosing regimens evaluated were dose proportional and linear. Murepavadin was well tolerated, adverse events were transient and generally mild, and no dose-limiting toxicity was identified. Copyright © 2018 American Society for Microbiology.

  14. Inactivation of single-chain urokinase-type plasminogen activator by thrombin in human subjects

    NARCIS (Netherlands)

    Braat, E. A.; Levi, M. [=Marcel M.; Bos, R.; Haverkate, F.; Lassen, M. R.; de Maat, M. P.; Rijken, D. C.

    1999-01-01

    Thrombin cleaves single-chain urokinase-type plasminogen activator (scu-PA) into a virtually inactive two-chain form (tcu-PA/T), a process that may protect a blood clot from early fibrinolysis. It is not known under what circumstances tcu-PA/T can be generated in vivo. We have studied the occurrence

  15. Designing Infographics to support teaching complex science subject: A comparison between static and animated Infographics

    Science.gov (United States)

    Hassan, Hesham Galal

    This thesis explores the proper principles and rules for creating excellent infographics that communicate information successfully and effectively. Not only does this thesis examine the creation of Infographics, it also tries to answer which format, Static or Animated Infographics, is the most effective when used as a teaching-aid framework for complex science subjects, and if compelling Infographics in the preferred format facilitate the learning experience. The methodology includes the creation of infographic using two formats (Static and Animated) of a fairly complex science subject (Phases Of The Moon), which were then tested for their efficacy as a whole, and the two formats were compared in terms of information comprehension and retention. My hypothesis predicts that the creation of an infographic using the animated format would be more effective in communicating a complex science subject (Phases Of The Moon), specifically when using 3D computer animation to visualize the topic. This would also help different types of learners to easily comprehend science subjects. Most of the animated infographics produced nowadays are created for marketing and business purposes and do not implement the analytical design principles required for creating excellent information design. I believe that science learners are still in need of more variety in their methods of learning information, and that infographics can be of great assistance. The results of this thesis study suggests that using properly designed infographics would be of great help in teaching complex science subjects that involve spatial and temporal data. This could facilitate learning science subjects and consequently impact the interest of young learners in STEM.

  16. No auditory experience, no tinnitus: Lessons from subjects with congenital- and acquired single-sided deafness.

    Science.gov (United States)

    Lee, Sang-Yeon; Nam, Dong Woo; Koo, Ja-Won; De Ridder, Dirk; Vanneste, Sven; Song, Jae-Jin

    2017-10-01

    Recent studies have adopted the Bayesian brain model to explain the generation of tinnitus in subjects with auditory deafferentation. That is, as the human brain works in a Bayesian manner to reduce environmental uncertainty, missing auditory information due to hearing loss may cause auditory phantom percepts, i.e., tinnitus. This type of deafferentation-induced auditory phantom percept should be preceded by auditory experience because the fill-in phenomenon, namely tinnitus, is based upon auditory prediction and the resultant prediction error. For example, a recent animal study observed the absence of tinnitus in cats with congenital single-sided deafness (SSD; Eggermont and Kral, Hear Res 2016). However, no human studies have investigated the presence and characteristics of tinnitus in subjects with congenital SSD. Thus, the present study sought to reveal differences in the generation of tinnitus between subjects with congenital SSD and those with acquired SSD to evaluate the replicability of previous animal studies. This study enrolled 20 subjects with congenital SSD and 44 subjects with acquired SSD and examined the presence and characteristics of tinnitus in the groups. None of the 20 subjects with congenital SSD perceived tinnitus on the affected side, whereas 30 of 44 subjects with acquired SSD experienced tinnitus on the affected side. Additionally, there were significant positive correlations between tinnitus characteristics and the audiometric characteristics of the SSD. In accordance with the findings of the recent animal study, tinnitus was absent in subjects with congenital SSD, but relatively frequent in subjects with acquired SSD, which suggests that the development of tinnitus should be preceded by auditory experience. In other words, subjects with profound congenital peripheral deafferentation do not develop auditory phantom percepts because no auditory predictions are available from the Bayesian brain. Copyright © 2017 Elsevier B.V. All rights

  17. Motion Correction of Single-Voxel Spectroscopy by Independent Component Analysis Applied to Spectra From Nonanesthetized Pediatric Subjects

    DEFF Research Database (Denmark)

    de Nijs, Robin; Miranda, Maria J.; Hansen, Lars Kai

    2009-01-01

    For single-voxel spectroscopy, the acquisition of the spectrum is typically repeated n times and then combined with a factor in order to improve the signal-to-noise ratio. In practice, the acquisitions are not only affected by random noise but also by physiologic motion and subject movements. Since...... the influence of physiologic motion such as cardiac and respiratory motion on the data is limited, it can be compensated for without data loss. Individual acquisitions hampered by subject movements, on the other hand, need to be rejected if no correction or compensation is possible. If the individual...

  18. A comparison in young and elderly subjects of the pharmacokinetics and pharmacodynamics of single and multiple doses of benazepril.

    Science.gov (United States)

    Macdonald, N J; Elliott, H L; Hughes, D M; Reid, J L

    1993-01-01

    1. The pharmacokinetics and pharmacodynamics of single and multiple oral doses of the ACE inhibitor benazepril were investigated in young and elderly normotensive subjects. 2. Following multiple doses the trough concentrations were significantly higher in the elderly and the areas under the plasma concentration-time curves (AUC0-24) were significantly greater, by approximately 23%. 3. The fall in blood pressure tended to be greater in the elderly subjects but this is likely to be attributable to their higher initial blood pressures, although it may reflect the small differences in pharmacokinetics. 4. The age related differences in kinetics and dynamics following multiple dosing are quantitatively similar to those obtained with single doses. However, there appears to be a quantitative difference between benazepril and other ACE inhibitors in that the age related increases were of a relatively smaller magnitude. PMID:9114904

  19. CRISPR library designer (CLD): software for multispecies design of single guide RNA libraries.

    Science.gov (United States)

    Heigwer, Florian; Zhan, Tianzuo; Breinig, Marco; Winter, Jan; Brügemann, Dirk; Leible, Svenja; Boutros, Michael

    2016-03-24

    Genetic screens using CRISPR/Cas9 are a powerful method for the functional analysis of genomes. Here we describe CRISPR library designer (CLD), an integrated bioinformatics application for the design of custom single guide RNA (sgRNA) libraries for all organisms with annotated genomes. CLD is suitable for the design of libraries using modified CRISPR enzymes and targeting non-coding regions. To demonstrate its utility, we perform a pooled screen for modulators of the TNF-related apoptosis inducing ligand (TRAIL) pathway using a custom library of 12,471 sgRNAs. CLD predicts a high fraction of functional sgRNAs and is publicly available at https://github.com/boutroslab/cld.

  20. AHSG tag single nucleotide polymorphisms associate with type 2 diabetes and dyslipidemia: studies of metabolic traits in 7,683 white Danish subjects

    DEFF Research Database (Denmark)

    Andersen, Gitte; Burgdorf, Kristoffer Sølvsten; Sparsø, Thomas

    2008-01-01

    been largely successful. We related seven frequent AHSG tag single nucleotide polymorphisms to a range of metabolic traits, including type 2 diabetes, obesity, and dyslipidemia. RESEARCH DESIGN AND METHODS: The polymorphisms were genotyped in 7,683 white Danish subjects using Taqman allelic...... with dyslipidemia (P = 0.003 and P(corr) = 0.009). Thr248Met (rs4917) tended to associate with lower fasting and post-oral glucose tolerance test serum insulin release (P = 0.02, P(corr) = 0.1 for fasting and P = 0.04, P(corr) = 0.2 for area under the insulin curve) and improved insulin sensitivity estimated...

  1. Alzheimer Disease and Behavioral Variant Frontotemporal Dementia: Automatic Classification Based on Cortical Atrophy for Single-Subject Diagnosis.

    Science.gov (United States)

    Möller, Christiane; Pijnenburg, Yolande A L; van der Flier, Wiesje M; Versteeg, Adriaan; Tijms, Betty; de Munck, Jan C; Hafkemeijer, Anne; Rombouts, Serge A R B; van der Grond, Jeroen; van Swieten, John; Dopper, Elise; Scheltens, Philip; Barkhof, Frederik; Vrenken, Hugo; Wink, Alle Meije

    2016-06-01

    Purpose To investigate the diagnostic accuracy of an image-based classifier to distinguish between Alzheimer disease (AD) and behavioral variant frontotemporal dementia (bvFTD) in individual patients by using gray matter (GM) density maps computed from standard T1-weighted structural images obtained with multiple imagers and with independent training and prediction data. Materials and Methods The local institutional review board approved the study. Eighty-four patients with AD, 51 patients with bvFTD, and 94 control subjects were divided into independent training (n = 115) and prediction (n = 114) sets with identical diagnosis and imager type distributions. Training of a support vector machine (SVM) classifier used diagnostic status and GM density maps and produced voxelwise discrimination maps. Discriminant function analysis was used to estimate suitability of the extracted weights for single-subject classification in the prediction set. Receiver operating characteristic (ROC) curves and area under the ROC curve (AUC) were calculated for image-based classifiers and neuropsychological z scores. Results Training accuracy of the SVM was 85% for patients with AD versus control subjects, 72% for patients with bvFTD versus control subjects, and 79% for patients with AD versus patients with bvFTD (P ≤ .029). Single-subject diagnosis in the prediction set when using the discrimination maps yielded accuracies of 88% for patients with AD versus control subjects, 85% for patients with bvFTD versus control subjects, and 82% for patients with AD versus patients with bvFTD, with a good to excellent AUC (range, 0.81-0.95; P ≤ .001). Machine learning-based categorization of AD versus bvFTD based on GM density maps outperforms classification based on neuropsychological test results. Conclusion The SVM can be used in single-subject discrimination and can help the clinician arrive at a diagnosis. The SVM can be used to distinguish disease-specific GM patterns in patients with AD

  2. GSK1265744 pharmacokinetics in plasma and tissue after single-dose long-acting injectable administration in healthy subjects.

    Science.gov (United States)

    Spreen, William; Ford, Susan L; Chen, Shuguang; Wilfret, David; Margolis, David; Gould, Elizabeth; Piscitelli, Stephen

    2014-12-15

    GSK1265744 (744) is an HIV-1 integrase inhibitor in clinical development as a long-acting (LA) injectable formulation. This study evaluated plasma and tissue pharmacokinetics after single-dose administration of 744 LA administered by intramuscular (IM) or subcutaneous injections. This was a phase I, open-label, 9-cohort, parallel study of 744 in healthy subjects. 744 was administered as a 200 mg/mL nanosuspension at doses of 100-800 mg IM and 100-400 mg subcutaneous. Eight (6 active and 2 placebo) male and female subjects participated in each of the first 7 cohorts. All 8 subjects, 4 males and 4 females, received active 744 LA in cohorts 8 and 9 and underwent rectal and cervicovaginal tissue sampling, respectively. Plasma pharmacokinetic sampling was performed for a minimum of 12 weeks or until 744 concentrations were ≤0.1 μg/mL. Rectal and cervicovaginal tissue biopsies were performed at weeks 2 and 8 (cohort 8) and weeks 4 and 12 (cohort 9). 744 LA was generally safe and well tolerated after single injections. A majority of subjects reported injection site reactions, all graded as mild in intensity. Plasma concentration-time profiles were prolonged with measureable concentrations up to 52 weeks after dosing. 744 LA 800 mg IM achieved mean concentrations above protein adjusted-IC90 for approximately 16 weeks. Rectal and cervicovaginal tissue concentrations ranged from injection has potential application as a monthly or less frequent HIV treatment or prevention agent.

  3. Performance evaluation of a piezoactuator-based single-stage valve system subjected to high temperature

    Science.gov (United States)

    Jeon, Juncheol; Han, Chulhee; Chung, Jye Ung; Choi, Seung-Bok

    2015-01-01

    In this paper, a novel single-stage valve system activated by a piezostack actuator is proposed and experimentally evaluated at both room temperature (20 °C) and high temperature (100 °C) conditions. A hinge-lever displacement amplifier is adopted in the valve system to magnify the displacement generated from the piezostack actuator. After explaining the operating principle of the proposed piezostack-driven single-stage valve system, the geometric dimensions and mechanical properties of the valve components are discussed in details. An experimental apparatus is then manufactured to evaluate the performances of the valve system such as flow rate. The experimental apparatus consists of a heat chamber, which can regulate the temperature of the valve system and oil, pneumatic-hydraulic cylinders, a hydraulic circuit, a pneumatic circuit, electronic devices, an interface card, and a high voltage amplifier. The pneumatic-hydraulic cylinder transforms the pneumatic pressure into hydraulic pressure. The performances of the valve system regarding spool response, pressure drop, and flow rate are evaluated and presented. In addition, the performance of the valve system under high temperature condition is compared with that under room temperature condition. The experimental results are plotted in both frequency and time domains.

  4. Performance evaluation of a piezoactuator-based single-stage valve system subjected to high temperature

    International Nuclear Information System (INIS)

    Jeon, Juncheol; Han, Chulhee; Ung Chung, Jye; Choi, Seung-Bok

    2015-01-01

    In this paper, a novel single-stage valve system activated by a piezostack actuator is proposed and experimentally evaluated at both room temperature (20 °C) and high temperature (100 °C) conditions. A hinge-lever displacement amplifier is adopted in the valve system to magnify the displacement generated from the piezostack actuator. After explaining the operating principle of the proposed piezostack-driven single-stage valve system, the geometric dimensions and mechanical properties of the valve components are discussed in details. An experimental apparatus is then manufactured to evaluate the performances of the valve system such as flow rate. The experimental apparatus consists of a heat chamber, which can regulate the temperature of the valve system and oil, pneumatic-hydraulic cylinders, a hydraulic circuit, a pneumatic circuit, electronic devices, an interface card, and a high voltage amplifier. The pneumatic-hydraulic cylinder transforms the pneumatic pressure into hydraulic pressure. The performances of the valve system regarding spool response, pressure drop, and flow rate are evaluated and presented. In addition, the performance of the valve system under high temperature condition is compared with that under room temperature condition. The experimental results are plotted in both frequency and time domains. (paper)

  5. Neurofeedback-Based Enhancement of Single Trial Auditory Evoked Potentials: Feasibility in Healthy Subjects.

    Science.gov (United States)

    Rieger, Kathryn; Rarra, Marie-Helene; Moor, Nicolas; Diaz Hernandez, Laura; Baenninger, Anja; Razavi, Nadja; Dierks, Thomas; Hubl, Daniela; Koenig, Thomas

    2018-03-01

    Previous studies showed a global reduction of the event-related potential component N100 in patients with schizophrenia, a phenomenon that is even more pronounced during auditory verbal hallucinations. This reduction assumingly results from dysfunctional activation of the primary auditory cortex by inner speech, which reduces its responsiveness to external stimuli. With this study, we tested the feasibility of enhancing the responsiveness of the primary auditory cortex to external stimuli with an upregulation of the event-related potential component N100 in healthy control subjects. A total of 15 healthy subjects performed 8 double-sessions of EEG-neurofeedback training over 2 weeks. The results of the used linear mixed effect model showed a significant active learning effect within sessions ( t = 5.99, P < .001) against an unspecific habituation effect that lowered the N100 amplitude over time. Across sessions, a significant increase in the passive condition ( t = 2.42, P = .03), named as carry-over effect, was observed. Given that the carry-over effect is one of the ultimate aims of neurofeedback, it seems reasonable to apply this neurofeedback training protocol to influence the N100 amplitude in patients with schizophrenia. This intervention could provide an alternative treatment option for auditory verbal hallucinations in these patients.

  6. Composite Estimation for Single-Index Models with Responses Subject to Detection Limits

    KAUST Repository

    Tang, Yanlin; Wang, Huixia Judy; Liang, Hua

    2017-01-01

    We propose a semiparametric estimator for single-index models with censored responses due to detection limits. In the presence of left censoring, the mean function cannot be identified without any parametric distributional assumptions, but the quantile function is still identifiable at upper quantile levels. To avoid parametric distributional assumption, we propose to fit censored quantile regression and combine information across quantile levels to estimate the unknown smooth link function and the index parameter. Under some regularity conditions, we show that the estimated link function achieves the non-parametric optimal convergence rate, and the estimated index parameter is asymptotically normal. The simulation study shows that the proposed estimator is competitive with the omniscient least squares estimator based on the latent uncensored responses for data with normal errors but much more efficient for heavy-tailed data under light and moderate censoring. The practical value of the proposed method is demonstrated through the analysis of a human immunodeficiency virus antibody data set.

  7. Fatigue crack growth behaviour of carbon steel piping material subjected to single overload/under-load

    International Nuclear Information System (INIS)

    Arora, Punit; Tripathi, R.; Singh, P.K.; Bhasin, V.; Vijayan, P.K.

    2016-01-01

    The objective of the present study is to understand the Fatigue Crack Growth Rate (FCGR) behaviour after single over-load/ under-load event on carbon steel piping material. The tests have been carried out on standard Compact Tension (CT) specimens. The effect of different crack length to width ratio (a/W) of specimen and overload/under-load ratios on FCGR have been studied. The studies have shown significant reduction in FCG rate after overload event. The strain field has been measured using Digital Image Correlation (DIC) technique ahead of the crack tip to quantify the plastic zone size due to overload and constant amplitude load. In addition, plastic zone calculations have also been carried out using 3D finite element analyses for the prediction of post overload FCGR/ life. The predicted FCGR are in agreement with experimentally determined FCGR. (author)

  8. Composite Estimation for Single-Index Models with Responses Subject to Detection Limits

    KAUST Repository

    Tang, Yanlin

    2017-11-03

    We propose a semiparametric estimator for single-index models with censored responses due to detection limits. In the presence of left censoring, the mean function cannot be identified without any parametric distributional assumptions, but the quantile function is still identifiable at upper quantile levels. To avoid parametric distributional assumption, we propose to fit censored quantile regression and combine information across quantile levels to estimate the unknown smooth link function and the index parameter. Under some regularity conditions, we show that the estimated link function achieves the non-parametric optimal convergence rate, and the estimated index parameter is asymptotically normal. The simulation study shows that the proposed estimator is competitive with the omniscient least squares estimator based on the latent uncensored responses for data with normal errors but much more efficient for heavy-tailed data under light and moderate censoring. The practical value of the proposed method is demonstrated through the analysis of a human immunodeficiency virus antibody data set.

  9. Cost Optimal Design of a Single-Phase Dry Power Transformer

    Directory of Open Access Journals (Sweden)

    Raju Basak

    2015-08-01

    Full Text Available The Dry type transformers are preferred to their oil-immersed counterparts for various reasons, particularly because their operation is hazardless. The application of dry transformers was limited to small ratings in the earlier days. But now these are being used for considerably higher ratings.  Therefore, their cost-optimal design has gained importance. This paper deals with the design procedure for achieving cost optimal design of a dry type single-phase power transformer of small rating, subject to usual design constraints on efficiency and voltage regulation. The selling cost for the transformer has been taken as the objective function. Only two key variables have been chosen, the turns/volt and the height: width ratio of window, which affects the cost function to high degrees. Other variables have been chosen on the basis of designers’ experience. Copper has been used as conductor material and CRGOS as core material to achieve higher efficiency, lower running cost and compact design. The electrical and magnetic loadings have been kept at their maximum values without violating the design constraints. The optimal solution has been obtained by the method of exhaustive search using nested loops.

  10. Design of Active Magnetic Bearing Controllers for Rotors Subjected to Gas Seal Forces

    DEFF Research Database (Denmark)

    Lauridsen, Jonas Skjødt; Santos, Ilmar F.

    2018-01-01

    Proper design of feedback controllers is crucial for ensuring high performance of Active Magnetic Bearing (AMB) supported rotor dynamic systems. Annular seals in those systems can contribute with significant forces, which, in many cases, are hard to model in advance due to complex geometries...... of the seal and multiphase fluids. Hence, it can be challenging to design AMB controllers that will guarantee robust performance for these kinds of systems. This paper demonstrates the design, simulation and experimental results of model based controllers for AMB systems, subjected to dynamic seal forces....... The controllers are found using H-infinity - and µ synthesis and are based on a global rotor dynamic model in-which the seal coefficients are identified in-situ. The controllers are implemented in a rotor-dynamic test facility with two radial AMBs and one annular seal with an adjustable inlet pressure. The seal...

  11. Pharmacokinetics and Safety of a Single Oral Dose of Mirogabalin in Japanese Subjects With Varying Degrees of Renal Impairment.

    Science.gov (United States)

    Kato, Manabu; Tajima, Naoyuki; Shimizu, Takako; Sugihara, Masahiro; Furihata, Kenichi; Harada, Kazuhiro; Ishizuka, Hitoshi

    2018-01-01

    Mirogabalin (DS-5565) is a novel preferentially selective α 2 δ-1 ligand being developed for the treatment of diabetic peripheral neuropathic pain and postherpetic neuralgia. The current multicenter open-label study determined the effect of varying degrees of renal impairment on the pharmacokinetics and safety of a single dose of mirogabalin 5 mg in Japanese subjects. A total of 30 subjects (6 subjects per renal function category [normal, mild, moderate, or severe impairment; and end-stage renal disease (ESRD)]) were enrolled and completed the study. The AUC last increased with severity of renal impairment; the geometric least-squares mean ratios of AUC last compared with subjects with normal renal function were 1.3, 1.9, 3.6, and 5.3 for patients with mild, moderate, and severe impairment and ESRD, respectively. In accordance with this AUC last increase, apparent total body clearance (CL/F), renal clearance (CLr), and the cumulative percentage of mirogabalin dose excreted into urine all decreased with severity of renal impairment. There were no deaths and no severe treatment-related adverse events (TEAEs), serious TEAEs, or TEAEs resulting in study discontinuation. Mirogabalin was well tolerated in Japanese subjects with normal renal function and those with mild to severe renal impairment. It was also tolerated in subjects with ESRD but with a higher incidence of TEAEs. The most frequently reported TEAEs were dizziness (ESRD, n = 3), somnolence (ESRD, n = 2), and vomiting (ESRD, n = 2). Based on these data, a mirogabalin dose adjustment will be considered in Japanese subjects with moderate to severe renal impairment and those with ESRD. © 2017, The Authors. The Journal of Clinical Pharmacology published by Wiley Periodicals, Inc. on behalf of American College of Clinical Pharmacology.

  12. Investigating Neuroanatomical Features in Top Athletes at the Single Subject Level.

    Science.gov (United States)

    Taubert, Marco; Wenzel, Uwe; Draganski, Bogdan; Kiebel, Stefan J; Ragert, Patrick; Krug, Jürgen; Villringer, Arno

    2015-01-01

    In sport events like Olympic Games or World Championships competitive athletes keep pushing the boundaries of human performance. Compared to team sports, high achievements in many athletic disciplines depend solely on the individual's performance. Contrasting previous research looking for expertise-related differences in brain anatomy at the group level, we aim to demonstrate changes in individual top athlete's brain, which would be averaged out in a group analysis. We compared structural magnetic resonance images (MRI) of three professional track-and-field athletes to age-, gender- and education-matched control subjects. To determine brain features specific to these top athletes, we tested for significant deviations in structural grey matter density between each of the three top athletes and a carefully matched control sample. While total brain volumes were comparable between athletes and controls, we show regional grey matter differences in striatum and thalamus. The demonstrated brain anatomy patterns remained stable and were detected after 2 years with Olympic Games in between. We also found differences in the fusiform gyrus in two top long jumpers. We interpret our findings in reward-related areas as correlates of top athletes' persistency to reach top-level skill performance over years.

  13. Investigating Neuroanatomical Features in Top Athletes at the Single Subject Level.

    Directory of Open Access Journals (Sweden)

    Marco Taubert

    Full Text Available In sport events like Olympic Games or World Championships competitive athletes keep pushing the boundaries of human performance. Compared to team sports, high achievements in many athletic disciplines depend solely on the individual's performance. Contrasting previous research looking for expertise-related differences in brain anatomy at the group level, we aim to demonstrate changes in individual top athlete's brain, which would be averaged out in a group analysis. We compared structural magnetic resonance images (MRI of three professional track-and-field athletes to age-, gender- and education-matched control subjects. To determine brain features specific to these top athletes, we tested for significant deviations in structural grey matter density between each of the three top athletes and a carefully matched control sample. While total brain volumes were comparable between athletes and controls, we show regional grey matter differences in striatum and thalamus. The demonstrated brain anatomy patterns remained stable and were detected after 2 years with Olympic Games in between. We also found differences in the fusiform gyrus in two top long jumpers. We interpret our findings in reward-related areas as correlates of top athletes' persistency to reach top-level skill performance over years.

  14. INFLUENCE OF SUBJECT AND OBJECTIVES FACTORS OF INFORMATIZATION ON THE PEDAGOGICAL DESIGN EFFICIENCY

    Directory of Open Access Journals (Sweden)

    Tamara O. Pushkareva

    2018-02-01

    Full Text Available In this article, a preliminary terminological analysis of the conceptual apparatus in the direction of computer-oriented informatization of pedagogical designing of educational activity in the structure of general secondary education has been made. The influence of the subject and object factors of the informatization of the educational process on the efficiency of pedagogical design is investigated. The existence of a dual problem in the educational sphere, related both to the formatting of an effective informational and educational product, and to the technologically acceptable component of well-organized computer-oriented support for students, is established. It is carried out the analysis of priority in the perception of varieties of information by the subjects of the educational system, as well as revealed that in the perception of computer information by subjects of different status or age there are differences that are related to their individual needs, desires, inclinations. The means of informative support of educational process are considered and recommendations on their use are given.

  15. Rational design of single-molecule magnets: a supramolecular approach.

    Science.gov (United States)

    Glaser, Thorsten

    2011-01-07

    Since the discovery that Mn(12)OAc acts as a single-molecule magnet (SMM), an increasing number of transition metal complexes have been demonstrated to behave as SMMs. The signature of a SMM is a slow relaxation of the magnetization at low temperatures accompanied by a magnetic hysteresis. The origin of SMM behaviour is the existence of an appreciable thermal barrier U for spin-reversal called magnetic anisotropy barrier which is related to the combination of a large total spin ground state (S(t)) and an easy-axis magnetic anisotropy. The extensive research on Mn(12)OAc and other SMMs has established more prerequisites for a rational development of new SMMs besides the high-spin ground state and the magnetic anisotropy: the symmetry should be at least C(3) to minimize the quantum tunneling of the magnetization through the anisotropy barrier but lower than cubic to avoid the cancellation of the local anisotropies upon projection onto the spin ground state. Based on these prerequisites, we have designed the ligand triplesalen which combines the phloroglucinol bridging unit for high spin ground states by the spin-polarization mechanism with a salen-like ligand environment for single-site magnetic anisotropies by a strong tetragonal ligand field. The C(3) symmetric, trinuclear complexes of the triplesalen ligand (talen(t-Bu(2)))(6-) exhibit a strong ligand folding resulting in an overall bowl-shaped molecular structure. This ligand folding preorganizes the axial coordination sites of the metal salen subunits for the complementary binding of three facial nitrogen atoms of a hexacyanometallate unit. This leads to a high driving force for the formation of heptanuclear complexes [M(t)(6)M(c)](n+) by the assembly of three molecular building blocks. Attractive van der Waals interactions of the tert-butyl phenyl units of two triplesalen trinuclear building blocks increase the driving force. In this respect, we have been able to synthesize the isostructural series [Mn(III)(6

  16. N-of-1-pathways MixEnrich: advancing precision medicine via single-subject analysis in discovering dynamic changes of transcriptomes.

    Science.gov (United States)

    Li, Qike; Schissler, A Grant; Gardeux, Vincent; Achour, Ikbel; Kenost, Colleen; Berghout, Joanne; Li, Haiquan; Zhang, Hao Helen; Lussier, Yves A

    2017-05-24

    Transcriptome analytic tools are commonly used across patient cohorts to develop drugs and predict clinical outcomes. However, as precision medicine pursues more accurate and individualized treatment decisions, these methods are not designed to address single-patient transcriptome analyses. We previously developed and validated the N-of-1-pathways framework using two methods, Wilcoxon and Mahalanobis Distance (MD), for personal transcriptome analysis derived from a pair of samples of a single patient. Although, both methods uncover concordantly dysregulated pathways, they are not designed to detect dysregulated pathways with up- and down-regulated genes (bidirectional dysregulation) that are ubiquitous in biological systems. We developed N-of-1-pathways MixEnrich, a mixture model followed by a gene set enrichment test, to uncover bidirectional and concordantly dysregulated pathways one patient at a time. We assess its accuracy in a comprehensive simulation study and in a RNA-Seq data analysis of head and neck squamous cell carcinomas (HNSCCs). In presence of bidirectionally dysregulated genes in the pathway or in presence of high background noise, MixEnrich substantially outperforms previous single-subject transcriptome analysis methods, both in the simulation study and the HNSCCs data analysis (ROC Curves; higher true positive rates; lower false positive rates). Bidirectional and concordant dysregulated pathways uncovered by MixEnrich in each patient largely overlapped with the quasi-gold standard compared to other single-subject and cohort-based transcriptome analyses. The greater performance of MixEnrich presents an advantage over previous methods to meet the promise of providing accurate personal transcriptome analysis to support precision medicine at point of care.

  17. Pet Bottle Design, Correlation Analysis Of Pet Bottle Characteristics Subjective Judgment

    Directory of Open Access Journals (Sweden)

    Darko Avramović

    2012-06-01

    Full Text Available Ability to predict consumer’s reaction to particular design solution of the product is very important. Gathering andanalysis of subjective judgments of particular characteristics, based on which the aesthetic of the product is judged,is one of predicting the consumer’s reaction in the future. Knowledge gathered this manner can serve as a referencefor further studies of determining factors for aesthetic results and design quality. There are two opposed opinionsregarding prediction of aesthetic impression. One opinion is that taste of individual cannot be discussed because itis extremely variable and the possibility of meaningful analysis of aesthetic impression is rejected. Other opinionstates that there is a consistent preference of certain aesthetic characteristics despite individual and group differences.Main goal of this paper is to examine the correlation between subjective judgments of certain PET bottlecharacteristics. Analysis showed meaningful correlation between some of the PET bottle characteristics while othercharacteristics showed less correlation. It can be concluded that not all of the characteristics have the same influenceon the aesthetics and design quality of the PET bottle form. Emphasizing the characteristics relative to aesthetics ofthe product can produce better market results, taking in to account that consumer’s buy the product they consider tobe more attractive if other parameters of the product are similar.

  18. Optimum Design of FGX-CNT-Reinforced Reddy Pipes Conveying Fluid Subjected to Moving Load

    Directory of Open Access Journals (Sweden)

    Farid Vakili Tahami

    2016-12-01

    Full Text Available The harmony search algorithm is applied to the optimum designs of functionally graded (FG-carbon nanotubes (CNTs-reinforced pipes conveying fluid which are subjected to a moving load. The structure is modeled by the Reddy cylindrical shell theory, and the motion equations are derived by Hamilton's principle. The dynamic displacement of the system is derived based on the differential quadrature method (DQM. Moreover, the length, thickness, diameter, velocity, and acceleration of the load, the temperature and velocity of the fluid, and the volume fraction of CNT are considered for the design variables. The results illustrate that the optimum diameter of the pipe is decreased by increasing the volume percentage of CNTs. In addition, by increasing the moving load velocity and acceleration, the FS is decreased.

  19. Pharmacokinetics, Safety and Tolerability of Sacubitril/Valsartan (LCZ696) After Single-Dose Administration in Healthy Chinese Subjects.

    Science.gov (United States)

    Han, Yi; Ayalasomayajula, Surya; Pan, Wei; Yang, Fan; Yuan, Yaozong; Langenickel, Thomas; Hinder, Markus; Kalluri, Sampath; Pal, Parasar; Sunkara, Gangadhar

    2017-02-01

    Sacubitril/valsartan (LCZ696) is a first-in-class angiotensin receptor neprilysin inhibitor (ARNI) and has been recently approved in several countries for the treatment of patients with heart failure and reduced ejection fraction. This was the first study conducted to characterise the pharmacokinetics of LCZ696 analytes (pro-drug sacubitril, active neprilysin inhibitor LBQ657 and valsartan) after single-dose administration of LCZ696 in healthy Chinese subjects. In this open-label, randomised, parallel-group study, following screening and baseline evaluation, eligible healthy subjects received single oral doses of LCZ696 50, 100, 200 or 400 mg. The pharmacokinetics, safety and tolerability of LCZ696 were assessed up to 72 h after dosing. A total of 40 healthy male subjects were enrolled, and all completed the study. Following oral administration, LCZ696 delivered systemic exposure to sacubitril, LBQ657 and valsartan with a median time to reach maximum plasma concentration (T max ) ranging from 0.50 to 1.25, 2.00 to 3.00 and 1.50 to 2.50 h, respectively, over the investigated dose range. The mean terminal elimination half-life (T 1/2 ) ranged from 0.89 to 1.35, 8.57 to 9.24 and 5.33 to 7.91 h for sacubitril, LBQ657 and valsartan, respectively. The area under the plasma concentration-time curve from time zero to the time of the last quantifiable concentration (AUC 0-last ), and maximum plasma concentration (C max ) for LBQ657 increased dose proportionally over the entire dose range. Dose linear increase in the exposure was observed across the dose range for sacubitril and valsartan. LCZ696 was safe and well tolerated at all doses in this study. Adverse events of only mild intensity, which required no treatment, were reported in 6 (15 %) subjects. The pharmacokinetic profiles of LCZ696 analytes in Chinese subjects are similar to those reported previously in Caucasian subjects.

  20. [Design of standard voice sample text for subjective auditory perceptual evaluation of voice disorders].

    Science.gov (United States)

    Li, Jin-rang; Sun, Yan-yan; Xu, Wen

    2010-09-01

    To design a speech voice sample text with all phonemes in Mandarin for subjective auditory perceptual evaluation of voice disorders. The principles for design of a speech voice sample text are: The short text should include the 21 initials and 39 finals, this may cover all the phonemes in Mandarin. Also, the short text should have some meanings. A short text was made out. It had 155 Chinese words, and included 21 initials and 38 finals (the final, ê, was not included because it was rarely used in Mandarin). Also, the text covered 17 light tones and one "Erhua". The constituent ratios of the initials and finals presented in this short text were statistically similar as those in Mandarin according to the method of similarity of the sample and population (r = 0.742, P text were statistically not similar as those in Mandarin (r = 0.731, P > 0.05). A speech voice sample text with all phonemes in Mandarin was made out. The constituent ratios of the initials and finals presented in this short text are similar as those in Mandarin. Its value for subjective auditory perceptual evaluation of voice disorders need further study.

  1. Quantum design rules for single molecule logic gates.

    Science.gov (United States)

    Renaud, N; Hliwa, M; Joachim, C

    2011-08-28

    Recent publications have demonstrated how to implement a NOR logic gate with a single molecule using its interaction with two surface atoms as logical inputs [W. Soe et al., ACS Nano, 2011, 5, 1436]. We demonstrate here how this NOR logic gate belongs to the general family of quantum logic gates where the Boolean truth table results from a full control of the quantum trajectory of the electron transfer process through the molecule by very local and classical inputs practiced on the molecule. A new molecule OR gate is proposed for the logical inputs to be also single metal atoms, one per logical input.

  2. Design of a single ion facility and its applications

    Energy Technology Data Exchange (ETDEWEB)

    Cholewa, M.; Saint, A.; Legge, G.J.F. [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1996-12-31

    The use of micro-irradiation techniques in radiobiology is not new; however, the current techniques take advantage of recent developments in particle delivery, focussing detection, image processing, cell recognition and computer control. These developments have generally come from other fields, for example microbeam elemental analysis techniques and single-event upset testing of semiconductor devices. Also in radiation biology there have been important advances in developments of individual cell assays, which allow a wide range of endpoints to be studied with good accuracy at low doses. Many of the studies that are planned involve following the responses of individual cells after a programmed exposure to charged-particle traversals. To probe the radiation sensitivity of a single cell and/or its constituents with a submicron resolution several developments are needed. The essential parameters of the proposed system can be summarised as follows: a focussed beam of ions of 300nm or less at the cell; a reliable (close to 100%) single ion detection; a fast beam switch to prevent second hits; a target holder adapted for the irradiation of wet cells and a fully automated system for cell recognition and single hits. 1 fig.

  3. Design of a single ion facility and its applications

    Energy Technology Data Exchange (ETDEWEB)

    Cholewa, M; Saint, A; Legge, G J.F. [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1997-12-31

    The use of micro-irradiation techniques in radiobiology is not new; however, the current techniques take advantage of recent developments in particle delivery, focussing detection, image processing, cell recognition and computer control. These developments have generally come from other fields, for example microbeam elemental analysis techniques and single-event upset testing of semiconductor devices. Also in radiation biology there have been important advances in developments of individual cell assays, which allow a wide range of endpoints to be studied with good accuracy at low doses. Many of the studies that are planned involve following the responses of individual cells after a programmed exposure to charged-particle traversals. To probe the radiation sensitivity of a single cell and/or its constituents with a submicron resolution several developments are needed. The essential parameters of the proposed system can be summarised as follows: a focussed beam of ions of 300nm or less at the cell; a reliable (close to 100%) single ion detection; a fast beam switch to prevent second hits; a target holder adapted for the irradiation of wet cells and a fully automated system for cell recognition and single hits. 1 fig.

  4. Single locus complementary sex determination in Hymenoptera : an "unintelligent" design?

    NARCIS (Netherlands)

    Wilgenburg, Ellen van; Driessen, Gerard; Beukeboom, Leo W.

    2006-01-01

    The haplodiploid sex determining mechanism in Hymenoptera (males are haploid, females are diploid) has played an important role in the evolution of this insect order. In Hymenoptera sex is usually determined by a single locus, heterozygotes are female and hemizygotes are male. Under inbreeding,

  5. Single locus complementary sex determination in Hymenoptera: an "unintelligent" design?

    NARCIS (Netherlands)

    van Wilgenburg, E.; Driessen, G.J.J.; Beukeboom, L.W.

    2006-01-01

    The haplodiploid sex determining mechanism in Hymenoptera (males are haploid, females are diploid) has played an important role in the evolution of this insect order. In Hymenoptera sex is usually determined by a single locus, heterozygotes are female and hemizygotes are male. Under inbreeding,

  6. Design and characterization of single photon avalanche diodes arrays

    Science.gov (United States)

    Neri, L.; Tudisco, S.; Lanzanò, L.; Musumeci, F.; Privitera, S.; Scordino, A.; Condorelli, G.; Fallica, G.; Mazzillo, M.; Sanfilippo, D.; Valvo, G.

    2010-05-01

    During the last years, in collaboration with ST-Microelectronics, we developed a new avalanche photo sensor, single photon avalanche diode (SPAD) see Ref.[S. Privitera, et al., Sensors 8 (2008) 4636 [1];S. Tudisco et al., IEEE Sensors Journal 8 (2008) 1324 [2

  7. Propagation of plasmons in designed single crystalline silver nanostructures

    DEFF Research Database (Denmark)

    Kumar, Shailesh; Lu, Ying-Wei; Huck, Alexander

    2012-01-01

    We demonstrate propagation of plasmons in single crystalline silver nanostructures fabricated using a combination of a bottom-up and a top-down approach. Silver nanoplates of thickness around 65 nm and a surface area of about 100 μm2 are made using a wet chemical method. Silver nanotips...

  8. Population pharmacokinetics of artesunate and dihydroartemisinin following single- and multiple-dosing of oral artesunate in healthy subjects

    Directory of Open Access Journals (Sweden)

    Kirsch Lee E

    2009-12-01

    Full Text Available Abstract Background The population pharmacokinetics of artesunate (AS and its active metabolite dihydroartemisinin (DHA were studied in healthy subjects receiving single- or multiple-dosing of AS orally either in combination with pyronaridine (PYR or as a monotherapy with or without food. Methods Data from 118 concentration-time profiles arising from 91 healthy Korean subjects were pooled from four Phase I clinical studies. Subjects received 2-5 mg/kg of single- and multiple-dosing of oral AS either in combination with PYR or as a monotherapy with or without food. Plasma AS and DHA were measured simultaneously using a validated liquid chromatography- mass spectrometric method with a lower limit of quantification of 1 ng/mL for both AS and DHA. Nonlinear mixed-effect modelling was used to obtain the pharmacokinetic and variability (inter-individual and residual variability parameter estimates. Results A novel parent-metabolite pharmacokinetic model consisting of a dosing compartment, a central compartment for AS, a central compartment and a peripheral compartment for DHA was developed. AS and DHA data were modelled simultaneously assuming stoichiometric conversion to DHA. AS was rapidly absorbed with a population estimate of absorption rate constant (Ka of 3.85 h-1. The population estimates of apparent clearance (CL/F and volume of distribution (V2/F for AS were 1190 L/h with 36.2% inter-individual variability (IIV and 1210 L with 57.4% IIV, respectively. For DHA, the population estimates of apparent clearance (CLM/F and central volume of distribution (V3/F were 93.7 L/h with 28% IIV and 97.1 L with 30% IIV, respectively. The population estimates of apparent inter-compartmental clearance (Q/F and peripheral volume of distribution (V4/F for DHA were 5.74 L/h and 18.5 L, respectively. Intake of high-fat and high-caloric meal prior to the drug administration resulted in 84% reduction in Ka. Body weight impacted CLM/F, such that a unit change in

  9. A randomized, single-blind, single-dose study evaluating the pharmacokinetic equivalence of proposed biosimilar ABP 980 and trastuzumab in healthy male subjects.

    Science.gov (United States)

    Hanes, Vladimir; Chow, Vincent; Zhang, Nan; Markus, Richard

    2017-05-01

    This study compared the pharmacokinetic (PK) profiles of the proposed biosimilar ABP 980 and trastuzumab in healthy males. In this single-blind study, 157 healthy males were randomized 1:1:1 to a single 6 mg/kg intravenous infusion of ABP 980, FDA-licensed trastuzumab [trastuzumab (US)], or EU-authorized trastuzumab [trastuzumab (EU)]. Primary endpoints were area under the serum concentration-time curve from time 0 to infinity (AUC inf ) and maximum observed serum concentration (C max ). To establish equivalence, the geometric mean ratio (GMR) and 90% confidence interval (CI) for C max and AUC inf had to be within the equivalence criteria of 0.80-1.25. The GMRs and 90% CIs for C max and AUC inf , respectively, were: 1.04 (0.99-1.08) and 1.06 (1.00-1.12) for ABP 980 versus trastuzumab (US); 0.99 (0.95-1.03) and 1.00 (0.95-1.06) for ABP 980 versus trastuzumab (EU); and 0.96 (0.92-1.00) and 0.95 (0.90-1.01) for trastuzumab (US) versus trastuzumab (EU). All comparisons were within the equivalence criteria of 0.80-1.25. Treatment-emergent adverse events (TEAEs) were reported in 84.0, 75.0, and 78.2 of subjects in the ABP 980, trastuzumab (US), and trastuzumab (EU) groups, respectively. There were no deaths or TEAEs leading to study discontinuation and no binding or neutralizing anti-drug anti-bodies were detected. This study demonstrated the PK similarity of ABP 980 to both trastuzumab (US) and trastuzumab (EU), and of trastuzumab (US) to trastuzumab (EU). No differences in safety and tolerability between treatments were noted; no subject tested positive for binding anti-bodies.

  10. Teaching Earth Sciences as an interdisciplinary subject: Novel module design involving research literature

    Science.gov (United States)

    Tong, Vincent C. H.

    2010-05-01

    The study of Earth Sciences requires an interdisciplinary approach as it involves understanding scientific knowledge originating from a wide spectrum of research areas. Not only does it include subjects ranging from, for instance, hydrogeology to deep crustal seismology and from climate science to oceanography, but it also has many direct applications in closely related disciplines such as environmental engineering and natural resources management. While research crossing traditional disciplinary boundaries in geosciences is becoming increasingly common, there is only limited integration of interdisciplinary research in the teaching of the subject. Given that the transition from undergraduate education based on subject modules to postgraduate interdisciplinary research is never easy, such integration is a highly desirable pedagogical approach at both undergraduate and postgraduate levels. My presentation is based on a recent teaching project involving novel design of an undergraduate course. The course is implemented in order to address the synergy between research and teaching (Tong, 2009). This project has been shown to be effective and successful in teaching geosciences undergraduates at the University of London. The module consists of studying core geophysical principles and linking them directly to a selection of recently published research papers in a wide range of interdisciplinary applications. Research reviewing and reporting techniques are systematically developed, practised and fully integrated into teaching of the core scientific theories. A fully-aligned assignment with a feedback website invites the students to reflect on the scientific knowledge and the study skills related to research literature they have acquired in the course. This teaching project has been recognized by a teaching award (http://www.clpd.bbk.ac.uk/staff/BETA). In this presentation, I will discuss how undergraduate teaching with a focus on research literature in Earth Sciences can

  11. Effectiveness of Play Therapy on Problem Behaviors of Children with Intellectual Disabilities: A Single Subject Design

    Science.gov (United States)

    Swan, Karrie L.

    2011-01-01

    A growing disparity between the mental health needs of children and their lack of treatment served as the basis of this study. To address this existent gap, I proposed that child-centered play therapy (CCPT), a holistic treatment that fosters children's emotional, developmental, and social growth would serve as a viable treatment. The purpose of…

  12. The reproducibility of binocular pattern reversal visual evoked potentials: a single subject design.

    Science.gov (United States)

    Mellow, Tessa B; Liasis, Alki; Lyons, Ruth; Thompson, Dorothy A

    2011-06-01

    This study aimed to investigate the within-participant variability over time of both amplitude and peak latency measures of pattern reversal visual evoked potentials (pVEPs). As a large number of factors are known to contribute to the variability of the pVEPs (such as fixation instability and drowsiness), testing was conducted in controlled conditions with two co-operative participants. PVEPs were recorded during 24 sessions, over an eight-week period using the same equipment and recording settings. The participants viewed a plasma monitor binocularly from a distance of 1 meter. High contrast (97%), black and white checks of side subtense 50', 25', and 12.5' pattern reversed 3/s in a 28 degree test field. The different sized checks were presented in a pseudo-random order. Three runs, each of 100 trials, were acquired to each stimulus from an active electrode placed at Oz referred to aFz. The amplitude of N80-P100 and the latency of P100 were measured. P100 amplitude and latency were stable across sessions and did not depend upon the order of check size presentation. As expected, variation in amplitude was greater than peak latency. The coefficients of variation for different check sizes and participants were 9-14% for pVEP amplitude, but only 1-2% for P100 latency.

  13. A randomised, single-blind, single-dose, three-arm, parallel-group study in healthy subjects to demonstrate pharmacokinetic equivalence of ABP 501 and adalimumab.

    Science.gov (United States)

    Kaur, Primal; Chow, Vincent; Zhang, Nan; Moxness, Michael; Kaliyaperumal, Arunan; Markus, Richard

    2017-03-01

    To demonstrate pharmacokinetic (PK) similarity of biosimilar candidate ABP 501 relative to adalimumab reference product from the USA and European Union (EU) and evaluate safety, tolerability and immunogenicity of ABP 501. Randomised, single-blind, single-dose, three-arm, parallel-group study; healthy subjects were randomised to receive ABP 501 (n=67), adalimumab (USA) (n=69) or adalimumab (EU) (n=67) 40 mg subcutaneously. Primary end points were area under the serum concentration-time curve from time 0 extrapolated to infinity (AUC inf ) and the maximum observed concentration (C max ). Secondary end points included safety and immunogenicity. AUC inf and C max were similar across the three groups. Geometrical mean ratio (GMR) of AUC inf was 1.11 between ABP 501 and adalimumab (USA), and 1.04 between ABP 501 and adalimumab (EU). GMR of C max was 1.04 between ABP 501 and adalimumab (USA) and 0.96 between ABP 501 and adalimumab (EU). The 90% CIs for the GMRs of AUC inf and C max were within the prespecified standard PK equivalence criteria of 0.80 to 1.25. Treatment-related adverse events were mild to moderate and were reported for 35.8%, 24.6% and 41.8% of subjects in the ABP 501, adalimumab (USA) and adalimumab (EU) groups; incidence of antidrug antibodies (ADAbs) was similar among the study groups. Results of this study demonstrated PK similarity of ABP 501 with adalimumab (USA) and adalimumab (EU) after a single 40-mg subcutaneous injection. No new safety signals with ABP 501 were identified. The safety and tolerability of ABP 501 was similar to the reference products, and similar ADAb rates were observed across the three groups. EudraCT number 2012-000785-37; Results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  14. Learned helplessness in the rat: effect of response topography in a within-subject design.

    Science.gov (United States)

    dos Santos, Cristiano Valerio; Gehm, Tauane; Hunziker, Maria Helena Leite

    2011-02-01

    Three experiments investigated learned helplessness in rats manipulating response topography within-subject and different intervals between treatment and tests among groups. In Experiment 1, rats previously exposed to inescapable shocks were tested under an escape contingency where either jumping or nose poking was required to terminate shocks; tests were run either 1, 14 or 28 days after treatment. Most rats failed to jump, as expected, but learned to nose poke, regardless of the interval between treatment and tests and order of testing. The same results were observed in male and female rats from a different laboratory (Experiment 2) and despite increased exposure to the escape contingencies using a within-subject design (Experiment 3). Furthermore, no evidence of helplessness reversal was observed, since animals failed to jump even after having learned to nose-poke in a previous test session. These results are not consistent with a learned helplessness hypothesis, which claims that shock (un)controllability is the key variable responsible for the effect. They are nonetheless consistent with the view that inescapable shocks enhance control by irrelevant features of the relationship between the environment and behavior. Copyright © 2010 Elsevier B.V. All rights reserved.

  15. design and operations challenges of a single toggle jaw crusher

    African Journals Online (AJOL)

    HOD

    [13] showed that the difference between Wall and Bond energies for hard rocks are .... advantages of retaining the structural design of the crusher and decreasing the ..... of aw crusher supporting structure fatigue failure”,. Stro niški Vestnik ...

  16. Design and control of single-phase dynamic voltage restorer

    Indian Academy of Sciences (India)

    Amit Meena

    ... voltage sag and swell. Modelling of the DVR and its controller design is included in ..... simulation study of DVR is accomplished in MATLAB/. Simulink. Parameters of ..... During this process, the PWM signals generated by the DSP are not as ...

  17. Weighing Designs to Detect a Single Counterfeit Coin

    Indian Academy of Sciences (India)

    IAS Admin

    research-level problems have been posed and resolved from time to time. .... 1b shows this method of fake coin detection. 2. ... the same weighing design) whether there is a fake coin of ..... He put all 101 pills in the last bottle, and mixed it up.

  18. Single locus complementary sex determination in Hymenoptera: an "unintelligent" design?

    Directory of Open Access Journals (Sweden)

    Driessen Gerard

    2006-01-01

    Full Text Available Abstract The haplodiploid sex determining mechanism in Hymenoptera (males are haploid, females are diploid has played an important role in the evolution of this insect order. In Hymenoptera sex is usually determined by a single locus, heterozygotes are female and hemizygotes are male. Under inbreeding, homozygous diploid and sterile males occur which form a genetic burden for a population. We review life history and genetical traits that may overcome the disadvantages of single locus complementary sex determination (sl-CSD. Behavioural adaptations to avoid matings between relatives include active dispersal from natal patches and mating preferences for non-relatives. In non-social species, temporal and spatial segregation of male and female offspring reduces the burden of sl-CSD. In social species, diploid males are produced at the expense of workers and female reproductives. In some social species, diploid males and diploid male producing queens are killed by workers. Diploid male production may have played a role in the evolution or maintenance of polygyny (multiple queens and polyandry (multiple mating. Some forms of thelytoky (parthenogenetic female production increase homozygosity and are therefore incompatible with sl-CSD. We discuss a number of hypothetical adaptations to sl-CSD which should be considered in future studies of this insect order.

  19. Controlling the formation of wrinkles in a single layer graphene sheet subjected to in-plane shear

    KAUST Repository

    Duan, Wen Hui

    2011-08-01

    The initiation and development of wrinkles in a single layer graphene sheet subjected to in-plane shear displacements are investigated. The dependence of the wavelength and amplitude of wrinkles on the applied shear displacements is explicitly obtained with molecular mechanics simulations. A continuum model is developed for the characteristics of the wrinkles which show that the wrinkle wavelength decreases with an increase in shear loading, while the amplitude of the wrinkles is found to initially increase and then become stable. The propagation and growth process of the wrinkles in the sheet is elucidated. It is expected that the research could promote applications of graphenes in the transportation of biological systems, separation science, and the development of the fluidic electronics. © 2011 Elsevier Ltd. All rights reserved.

  20. Accelerated reliability testing of highly aligned single-walled carbon nanotube networks subjected to DC electrical stressing.

    Science.gov (United States)

    Strus, Mark C; Chiaramonti, Ann N; Kim, Young Lae; Jung, Yung Joon; Keller, Robert R

    2011-07-01

    We investigate the electrical reliability of nanoscale lines of highly aligned, networked, metallic/semiconducting single-walled carbon nanotubes (SWCNTs) fabricated through a template-based fluidic assembly process. We find that these SWCNT networks can withstand DC current densities larger than 10 MA cm(-2) for several hours and, in some cases, several days. We develop test methods that show that the degradation rate, failure predictability and total device lifetime can be linked to the initial resistance. Scanning electron and transmission electron microscopy suggest that fabrication variability plays a critical role in the rate of degradation, and we offer an empirical method of quickly determining the long-term performance of a network. We find that well-fabricated lines subject to constant electrical stress show a linear accumulation of damage reminiscent of electromigration in metallic interconnects, and we explore the underlying physical mechanisms that could cause such behavior.

  1. Within-Subject Mediation Analysis in AB/BA Crossover Designs.

    Science.gov (United States)

    Josephy, Haeike; Vansteelandt, Stijn; Vanderhasselt, Marie-Anne; Loeys, Tom

    2015-05-01

    Crossover trials are widely used to assess the effect of a reversible exposure on an outcome of interest. To gain further insight into the underlying mechanisms of this effect, researchers may be interested in exploring whether or not it runs through a specific intermediate variable: the mediator. Mediation analysis in crossover designs has received scant attention so far and is mostly confined to the traditional Baron and Kenny approach. We aim to tackle mediation analysis within the counterfactual framework and elucidate the assumptions under which the direct and indirect effects can be identified in AB/BA crossover studies. Notably, we show that both effects are identifiable in certain statistical models, even in the presence of unmeasured time-independent (or upper-level) confounding of the mediator-outcome relation. Employing the mediation formula, we derive expressions for the direct and indirect effects in within-subject designs for continuous outcomes that lend themselves to linear modelling, under a large variety of settings. We discuss an estimation approach based on regressing differences in outcomes on differences in mediators and show how to allow for period effects as well as different types of moderation. The performance of this approach is compared to other existing methods through simulations and is illustrated with data from a neurobehavioural study. Lastly, we demonstrate how a sensitivity analysis can be performed that is able to assess the robustness of both the direct and indirect effect against violation of the "no unmeasured lower-level mediator-outcome confounding" assumption.

  2. Development of the complex general linear model in the Fourier domain: application to fMRI multiple input-output evoked responses for single subjects.

    Science.gov (United States)

    Rio, Daniel E; Rawlings, Robert R; Woltz, Lawrence A; Gilman, Jodi; Hommer, Daniel W

    2013-01-01

    A linear time-invariant model based on statistical time series analysis in the Fourier domain for single subjects is further developed and applied to functional MRI (fMRI) blood-oxygen level-dependent (BOLD) multivariate data. This methodology was originally developed to analyze multiple stimulus input evoked response BOLD data. However, to analyze clinical data generated using a repeated measures experimental design, the model has been extended to handle multivariate time series data and demonstrated on control and alcoholic subjects taken from data previously analyzed in the temporal domain. Analysis of BOLD data is typically carried out in the time domain where the data has a high temporal correlation. These analyses generally employ parametric models of the hemodynamic response function (HRF) where prewhitening of the data is attempted using autoregressive (AR) models for the noise. However, this data can be analyzed in the Fourier domain. Here, assumptions made on the noise structure are less restrictive, and hypothesis tests can be constructed based on voxel-specific nonparametric estimates of the hemodynamic transfer function (HRF in the Fourier domain). This is especially important for experimental designs involving multiple states (either stimulus or drug induced) that may alter the form of the response function.

  3. Estimation methods with ordered exposure subject to measurement error and missingness in semi-ecological design

    Directory of Open Access Journals (Sweden)

    Kim Hyang-Mi

    2012-09-01

    Full Text Available Abstract Background In epidemiological studies, it is often not possible to measure accurately exposures of participants even if their response variable can be measured without error. When there are several groups of subjects, occupational epidemiologists employ group-based strategy (GBS for exposure assessment to reduce bias due to measurement errors: individuals of a group/job within study sample are assigned commonly to the sample mean of exposure measurements from their group in evaluating the effect of exposure on the response. Therefore, exposure is estimated on an ecological level while health outcomes are ascertained for each subject. Such study design leads to negligible bias in risk estimates when group means are estimated from ‘large’ samples. However, in many cases, only a small number of observations are available to estimate the group means, and this causes bias in the observed exposure-disease association. Also, the analysis in a semi-ecological design may involve exposure data with the majority missing and the rest observed with measurement errors and complete response data collected with ascertainment. Methods In workplaces groups/jobs are naturally ordered and this could be incorporated in estimation procedure by constrained estimation methods together with the expectation and maximization (EM algorithms for regression models having measurement error and missing values. Four methods were compared by a simulation study: naive complete-case analysis, GBS, the constrained GBS (CGBS, and the constrained expectation and maximization (CEM. We illustrated the methods in the analysis of decline in lung function due to exposures to carbon black. Results Naive and GBS approaches were shown to be inadequate when the number of exposure measurements is too small to accurately estimate group means. The CEM method appears to be best among them when within each exposure group at least a ’moderate’ number of individuals have their

  4. Efficacy of Executive Functions Training (Response Inhibition on the Rate of Impulsivity in Preschool Children with Developmental Coordination Disorder: A Single-Subject Research

    Directory of Open Access Journals (Sweden)

    Farnoush Kavianpour

    2013-04-01

    Full Text Available Objectives: The present study aims to investigate the efficacy of executive functions training (response inhibition on the rate of impulsivity in preschool children with developmental coordination disorder in Isfahan city.  Materials & Methods: The participants of this study were three preschool children which were recognized to have developmental coordination disorder. To collect data, we used NEPSY neuropsychology test, Conner’s parent rating scale, Wechsler intelligence scale for children, basic motor ability tests and clinical interview. A single-subject method with MBD design research methodology was used as well. Results: The results of the data chart analysis based on descriptive statistics' and visual analysis indices revealed that the intervention has been effective on the three participants (PND of 80%, 70% and 70% for test number one, two and three, respectively. Conclusion: The results of the present study show that response inhibition executive function training can reduce level of impulsivity.

  5. The pharmacokinetics of peginterferon lambda-1a following single dose administration to subjects with impaired renal function.

    Science.gov (United States)

    Hruska, Matthew W; Adamczyk, Robert; Colston, Elizabeth; Hesney, Michael; Stonier, Michele; Myler, Heather; Bertz, Richard

    2015-09-01

    This open label study was conducted to assess the effect of renal impairment (RI) on the pharmacokinetics (PK) of peginterferon lambda-1a (Lambda). Subjects (age 18-75 years, BMI 18-35 kg m(-2) ) were enrolled into one of five renal function groups: normal (n = 12), mild RI (n = 8), moderate RI (n = 8), severe RI (n = 7), end-stage renal disease (ESRD, n = 8) based on estimated glomerular filtration rate (eGFR) calculated using the Modification of Diet in Renal Disease (MDRD) equation. Subjects received a single dose of Lambda (180 µg) subcutaneously on day 1 followed by PK serum sample collections through day 29. Safety, tolerability and immunogenicity data were collected through day 43. PK parameters were estimated and summarized by group. Geometric mean ratios (GMR) and 90% confidence intervals (CIs) were calculated between normal and RI groups. With decreasing eGFR, Lambda exposure (Cmax , AUC) increased while apparent clearance (CL/F) and apparent volume of distribution (V/F) decreased. Relative to subjects with normal renal function (geometric mean AUC = 99.5 ng ml(-1) h), Lambda exposure estimates (AUC) were slightly increased in the mild RI group (geometric mean [90% CI]: 1.20 [0.82, 1.77]) and greater in the moderate (1.95 [1.35, 2.83]), severe RI (1.95 [1.30, 2.93]) and ESRD (1.88 [1.30, 2.73]) groups. Lambda was generally well tolerated. The results demonstrated that RI reduces the clearance of Lambda and suggests that dose modifications may not be required in patients with mild RI but may be required in patients with moderate to severe RI or ESRD. © 2015 The British Pharmacological Society.

  6. Single-case research design in pediatric psychology: considerations regarding data analysis.

    Science.gov (United States)

    Cohen, Lindsey L; Feinstein, Amanda; Masuda, Akihiko; Vowles, Kevin E

    2014-03-01

    Single-case research allows for an examination of behavior and can demonstrate the functional relation between intervention and outcome in pediatric psychology. This review highlights key assumptions, methodological and design considerations, and options for data analysis. Single-case methodology and guidelines are reviewed with an in-depth focus on visual and statistical analyses. Guidelines allow for the careful evaluation of design quality and visual analysis. A number of statistical techniques have been introduced to supplement visual analysis, but to date, there is no consensus on their recommended use in single-case research design. Single-case methodology is invaluable for advancing pediatric psychology science and practice, and guidelines have been introduced to enhance the consistency, validity, and reliability of these studies. Experts generally agree that visual inspection is the optimal method of analysis in single-case design; however, statistical approaches are becoming increasingly evaluated and used to augment data interpretation.

  7. Design of all solid state tunable single-mode Ti: sapphire laser for nuclear industry

    International Nuclear Information System (INIS)

    Lee, J.H.; Nam, S.M.; Lee, Y.J.; Lee, J.M.; Horn, Roland E.; Wendt, Klaus

    1999-01-01

    We designed a Ti:Sapphire laser pumped by a diode laser pumped solid state laser (DPSSL). The DPSSL was intra-cavity frequency doubled and it had 20 W output power. The Ti:Sapphire laser was designed for single longitudinal mode lasing. For single mode lasing, the laser used several solid etalons. We simulated temporal evolution of the laser pulse and single pass amplification rate of the photons in each modes from rate equations. From the result, we found that single mode lasing is viable in this cavity

  8. Shedding light on the subject: introduction to illumination engineering and design for multidiscipline engineering students

    Science.gov (United States)

    Ronen, Ram S.; Smith, R. Frank

    1995-10-01

    Educating engineers and architects in Illumination Engineering and related subjects has become a very important field and a very satisfying and rewarding one. Main reasons include the need to significantly conserve lighting energy and meet government regulations while supplying appropriate light levels and achieving aesthetical requirements. The proliferation of new lamps, luminaries and lighting controllers many of which are 'energy savers' also helps a trend to seek help from lighting engineers when designing new commercial and residential buildings. That trend is believed to continue and grow as benefits become attractive and new government conservation regulations take affect. To make things even better one notices that Engineering and Science students in most disciplines make excellent candidates for Illumination Engineers because of their background and teaching them can move ahead at a brisk pace and be a rewarding experience nevertheless. In the past two years, Cal Poly Pomona College of Engineering has been the beneficiary of a DOE/California grant. Its purpose was to precipitate and oversee light curricula in various California community colleges and also develop and launch an Illumination Engineering minor at Cal Poly University. Both objectives have successfully been met. Numerous community colleges throughout California developed and are offering a sequence of six lighting courses leading to a certificate; the first graduating class is now coming out of both Cypress and Consumnes Community Colleges. At Cal Poly University a four course/laboratory sequence leading to a minor in Illumination Engineering (ILE) is now offered to upper division students in the College of Engineering, College of Science and College of Architecture and Design. The ILE sequence will briefly be described. The first course, Introduction to Illumination Engineering and its laboratory are described in more detail alter. Various methods of instruction including lectures, self work

  9. Design And Development Of An Automatic Single Phase Protective Device Using Ssr

    Directory of Open Access Journals (Sweden)

    Michael E.

    2017-10-01

    Full Text Available Since the discovery of energy safety has been a paramount subject matter. This we can see in todays electrical systems where protective devices such as fuse and circuit breakers are used to prevent fire hazards resulting from overload overvoltage and short circuits. However with all the revolution in technology these options may be considered less smart since the fuse made with wire strands calculated for specific current capacity faults permanently when the specified current rating is exceeded. While the circuit breaker which is made up of mechanical switch fails as a result of carbon forming and the wearing away of the contacts because of arcing. As a means of improvement this paper presents the design and development of an automatic single phase protective device using solid state relay SSR. This study is to ensure automatic cut off from power supply in cases of overvoltage above 240 V AC or when overload and short circuit current above 8amps is detected without permanent damage of a fuse placed along current path. Also the design will ensure that there is an automatic close circuit whenever the trigger switch is momentary switch is closed. The system is achieved via the use of PIC micro-controller current sensor and other discrete components. The system is tested and works well inhibiting the frequent faulting of fuses. It also helps to prevent hazard as a result of overvoltage overload and short circuit and ensures a close circuit when the trigger switch is closed.

  10. Single mode optical fiber vibration sensor: design and development

    Science.gov (United States)

    Alanis-Carranza, L. E.; Alvarez-Chavez, J. A.; Perez-Sanchez, G. G.; Sierra-Calderon, A.; Rodriguez-Novelo, J. C.

    2016-09-01

    This work deals with the design and development of an SMF28-based vibration detector including the fiber segment, the data acquisition via an NI-USB-6212 card, the data processing code in Visual Basic and the signal spectrum obtained via Fourier analysis. The set-up consists of a regulated voltage source at 2.6V, 300mA, which serves as the power source for a 980nm semiconductor laser operating at 150mW which is fiber coupled into a 20m-piece of SMF-28 fiber. Perpendicular to such fiber the perturbations ranged from 1 to 100 kHz, coming from a DC motor at 12 Volts. At the detection stage, a simple analog filter and a commercial photo diode were employed for data acquisition, before a transimpedance amplification stage reconstructed the signal into the National Instruments data acquisition card. At the output, the signals Fourier transformation allows the signal to be displayed in a personal computer. The presentation will include a full electrical and optical characterization of the device and preliminary sensing results, which could be suitable for structural health monitoring applications.

  11. Single session imaging of cerebellum at 7 Tesla: obtaining structure and function of multiple motor subsystems in individual subjects.

    Directory of Open Access Journals (Sweden)

    Melissa A Batson

    Full Text Available The recent increase in the use of high field MR systems is accompanied by a demand for acquisition techniques and coil systems that can take advantage of increased power and accuracy without being susceptible to increased noise. Physical location and anatomical complexity of targeted regions must be considered when attempting to image deeper structures with small nuclei and/or complex cytoarchitechtonics (i.e. small microvasculature and deep nuclei, such as the brainstem and the cerebellum (Cb. Once these obstacles are overcome, the concomitant increase in signal strength at higher field strength should allow for faster acquisition of MR images. Here we show that it is technically feasible to quickly and accurately detect blood oxygen level dependent (BOLD signal changes and obtain anatomical images of Cb at high spatial resolutions in individual subjects at 7 Tesla in a single one-hour session. Images were obtained using two high-density multi-element surface coils (32 channels in total placed beneath the head at the level of Cb, two channel transmission, and three-dimensional sensitivity encoded (3D, SENSE acquisitions to investigate sensorimotor activations in Cb. Two classic sensorimotor tasks were used to detect Cb activations. BOLD signal changes during motor activity resulted in concentrated clusters of activity within the Cb lobules associated with each task, observed consistently and independently in each subject: Oculomotor vermis (VI/VII and CrusI/II for pro- and anti-saccades; ipsilateral hemispheres IV-VI for finger tapping; and topographical separation of eye- and hand- activations in hemispheres VI and VIIb/VIII. Though fast temporal resolution was not attempted here, these functional patches of highly specific BOLD signal changes may reflect small-scale shunting of blood in the microvasculature of Cb. The observed improvements in acquisition time and signal detection are ideal for individualized investigations such as

  12. Design parameters for voltage-controllable directed assembly of single nanoparticles

    International Nuclear Information System (INIS)

    Porter, Benjamin F; Bhaskaran, Harish; Abelmann, Leon

    2013-01-01

    Techniques to reliably pick-and-place single nanoparticles into functional assemblies are required to incorporate exotic nanoparticles into standard electronic circuits. In this paper we explore the use of electric fields to drive and direct the assembly process, which has the advantage of being able to control the nano-assembly process at the single nanoparticle level. To achieve this, we design an electrostatic gating system, thus enabling a voltage-controllable nanoparticle picking technique. Simulating this system with the nonlinear Poisson–Boltzmann equation, we can successfully characterize the parameters required for single particle placement, the key being single particle selectivity, in effect designing a system that can achieve this controllably. We then present the optimum design parameters required for successful single nanoparticle placement at ambient temperature, an important requirement for nanomanufacturing processes. (paper)

  13. Clinical trial: single- and multiple-dose pharmacokinetics of polyethylene glycol (PEG-3350) in healthy young and elderly subjects.

    Science.gov (United States)

    Pelham, R W; Nix, L C; Chavira, R E; Cleveland, M Vb; Stetson, P

    2008-07-01

    The pharmacokinetics of polyethylene glycol 3350 (PEG-3350) have not been fully described because of lack of a sufficiently sensitive analytical method. To describe the pharmacokinetics of PEG-3350 in humans. A highly sensitive, high performance liquid chromatography with mass spectrometry (HPLC/MS/MS) method was developed for PEG-3350 in urine, plasma and faeces with quantification limits of 30 ng/mL, 100 ng/mL and 500 microg/g respectively. Noncompartmental pharmacokinetics methods were used and the effects of gender, age, renal status and dosing frequency were examined after the oral administration of 17 g to healthy volunteers. Peak PEG-3350 plasma concentrations occurred at 2-4 h and declined to nonquantifiable levels usually within 18 h after single and multiple doses, with a half-life of about 4-6 h. Steady state was reached within 5 days of dosing. Mean urinary excretion of the administered dose ranged from 0.19% to 0.25%. Age, gender or mild kidney impairment did not alter the pharmacokinetics of PEG-3350. Mean faecal excretion of the administered dose was 93% in young subjects. For the first time, a highly sensitive assay allowed comprehensive pharmacokinetics studies of PEG-3350 in humans. These studies confirmed that orally administered PEG-3350 is minimally absorbed, rapidly excreted and primarily eliminated via faeces.

  14. Can Air Seat Cushions and Ball Chairs Improved Classroom Behaviors of Students with Autism Spectrum Disorder: A Single Subject Study

    Directory of Open Access Journals (Sweden)

    Nader Matin Sadr

    2015-06-01

    Full Text Available Background: Classroom behaviorsare disturbed in autistic students because of their repetitive, restlessness, and disruptive behaviors. This study aimed to examine the impacts of sitting on a ball, cushion, and/or common chair on classroom behavior of four students with Autism Spectrum Disorder (ASD. Methods: Four children with Autism participated in this single-subject study. Students’ behaviors were video recorded in three phases: Sitting on their common chairs during phase A, air-sit cushioned in phase B, and ball chairs in phase C. Sitting times and on-task/off-task behaviors were quantified by momentary time sampling (every 10 seconds and compared during different phases for important changes. Social validity was taken by the teacher at the end of the research as well. Results: The findings demonstrated increases in on-task and in-seat behaviors in four students when seated on air sit cushioned chairs. Despite rises of ontask behaviors for all students, only two of the students showed enhanced inseat behaviors when seated on therapy balls. Social validity findings indicated that the teacher preferred the use of the balls and air-cushioned chairs for her students. Conclusion: Therapy balls/cushioned chairs for students with ASD may facilitate in-seat and on-task behavior.

  15. Max-min SINR low complexity transceiver design for single cell massive MIMO

    KAUST Repository

    Sifaou, Houssem; Kammoun, Abla; Sanguinetti, Luca; Debbah, Mé rouane; Alouini, Mohamed-Slim

    2016-01-01

    This work focuses on large scale multi-user MIMO systems in which the base station (BS) outfitted with M antennas communicates with K single antenna user equipments (UEs). In particular, we aim at designing the linear precoder and receiver

  16. Design and evaluation of a single-span bridge using ultra-high performance concrete.

    Science.gov (United States)

    2009-09-01

    "Research presented herein describes an application of a newly developed material called Ultra-High Performance Concrete (UHPC) to a : single-span bridge. The two primary objectives of this research were to develop a shear design procedure for possib...

  17. Challenges in thermal design of industrial single-phase power inverter

    Directory of Open Access Journals (Sweden)

    Ninković Predrag

    2016-01-01

    Full Text Available This paper presents the influence of thermal aspects in design process of an industrial single-phase inverter, choice of its topology and components. Stringent design inputs like very high overload level, demand for natural cooling and very wide input voltage range have made conventional circuit topology inappropriate therefore asking for alternative solution. Different power losses calculations in semiconductors are performed and compared, outlining the guidelines how to choose the final topology. Some recommendations in power magnetic components design are given. Based on the final project, a 20kVA single-phase inverter for thermal power plant supervisory and control system is designed and commissioned.

  18. The Immediate Effects of Conventional Physical Therapy on the Knee Joint Load in Subjects with Moderate Knee Osteoarthritis; A Preliminary Single Blinded Randomized Control Trial

    Directory of Open Access Journals (Sweden)

    Leila Fattahi

    2015-12-01

    Full Text Available Background: Subjects with knee osteoarthritis typically have higher knee adduction moment. Current research efforts are mainly focused on therapeutic procedures that potentially may modify disease progression. This preliminary study was designed as a single blind (examiner randomized control trial to investigate the impact of conventional physical therapy on pain, and knee joint load in subjects with moderate knee osteoarthritis. Methods: Twelve participants diagnosed with moderate knee OA were randomly assigned into control and intervention groups. Three-dimensional knee kinematic and kinetic data were recorded during the gait before and after 10 sessions of conventional physical therapy. In addition, pain intensity was evaluated by visual analog scale and pain subscale of KOOS questionnaire. The control group did not receive any intervention during the same period. Gait parameters were analyzed within and between groups using nonparametric tests. Results: There was a significant difference between groups in baseline KOOS-pain Score and ML knee force (P=0.048 and P=0.01. Immediately after ten sessions of physical therapy the initial (first peak of knee adduction moment was significantly (P=0.03 lower than that of the control group while the first and second peak of knee AP velocity were significantly (P=0.02, P=0.01 respectively higher. In the intervention group, the second peaks of vertical and anteroposterior (AP knee forces were strongly correlated with the pretest KOOS-pain Score (r=0.99 and r=0.98, P<0.001. Therefore a multivariate general linear model was adopted with adjustment to baseline KOOS-pain. By this adjustment, 51% alleviation of VAS pain score and 81% decrement of first peak of knee adduction moment in comparison to control group was statistically significant (P=0.02, P=0.03 respectively. Conclusion: It seems that ten sessions of conventional physical therapy may modify knee joint load in subjects with moderate knee

  19. Influences of crystallographic orientations on deformation mechanism and grain refinement of Al single crystals subjected to one-pass equal-channel angular pressing

    International Nuclear Information System (INIS)

    Han, W.Z.; Zhang, Z.F.; Wu, S.D.; Li, S.X.

    2007-01-01

    The influences of crystallographic orientations on the evolution of dislocation structures and the refinement process of sub-grains in Al single crystals processed by one-pass equal-channel angular pressing (ECAP) were systematically investigated by means of scanning electron microscopy, electron backscatter diffraction and transmission electron microscopy. Three single crystals with different orientations, denoted as crystal I, crystal II and crystal III, were specially designed according to the shape of the ECAP die. For crystal I, its insert direction is parallel to [1 1 0] and its extrusion direction is parallel to [1-bar11]. For crystal II, the (1-bar11) plane is located parallel to the intersection plane of the ECAP die, and the [1 1 0] direction is along the general shear direction on the intersection plane. For crystal III, the (1-bar11) plane is laid on the plane perpendicular to the intersection of the ECAP die, and the [1 1 0] direction is vertical to the general shear direction. For crystal I, abundant cell block structures with multi-slip characters were formed, and they should be induced by four symmetric slip systems, while for crystal II, there are two sets of sub-grain structures with higher misorientation, making an angle of ∼70 deg., which can be attributed to the interactions of the two asymmetric primary slip planes, whereas for crystal III, only one set of ribbon structures was parallel to the traces of (1-bar11) with the lowest misorientation angle among the three single crystals, which should result from the homogeneous slip on the primary slip plane. The different microstructural features of the three single crystals provide clear experimental evidence that the microstructures and misorientation evolution are strongly affected by the crystallographic orientation or by the interaction between shear deformation imposed by the ECAP die and the intrinsic slip deformation of the single crystals. Based on the experimental results and the

  20. Max-min SINR low complexity transceiver design for single cell massive MIMO

    KAUST Repository

    Sifaou, Houssem

    2016-08-11

    This work focuses on large scale multi-user MIMO systems in which the base station (BS) outfitted with M antennas communicates with K single antenna user equipments (UEs). In particular, we aim at designing the linear precoder and receiver that maximizes the minimum signal-to-interference-plus-noise ratio (SINR) subject to a given power constraint. To gain insights into the structure of the optimal precoder and receiver as well as to reduce the computational complexity for their implementation, we analyze the asymptotic regime where M and K grow large with a given ratio and make use of random matrix theory (RMT) tools to compute accurate approximations. Although simpler, the implementation of the asymptotic precoder and receiver requires fast inversions of large matrices in every coherence period. To overcome this issue, we apply the truncated polynomial expansion (TPE) technique to the precoding and receiving vector of each UE and make use of RMT to determine the optimal weighting coefficients that asymptotically solve the max-min SINR problem. Numerical results are used to show that the proposed TPE-based precoder and receiver almost achieve the same performance as the optimal ones while requiring a lower complexity.

  1. Crossover learning of gestures in two ideomotor apraxia patients: A single case experimental design study.

    Science.gov (United States)

    Shimizu, Daisuke; Tanemura, Rumi

    2017-06-01

    Crossover learning may aid rehabilitation in patients with neurological disorders. Ideomotor apraxia (IMA) is a common sequela of left-brain damage that comprises a deficit in the ability to perform gestures to verbal commands or by imitation. This study elucidated whether crossover learning occurred in two post-stroke IMA patients without motor paralysis after gesture training approximately 2 months after stroke onset. We quantitatively analysed the therapeutic intervention history and investigated whether revised action occurred during gesture production. Treatment intervention was to examine how to influence improvement and generalisation of the ability to produce the gesture. This study used an alternating treatments single-subject design, and the intervention method was errorless learning. Results indicated crossover learning in both patients. Qualitative analysis indicated that revised action occurred during the gesture-production process in one patient and that there were two types of post-revised action gestures: correct and incorrect gestures. We also discovered that even when a comparably short time had elapsed since stroke onset, generalisation was difficult. Information transfer between the left and right hemispheres of the brain via commissural fibres is important in crossover learning. In conclusion, improvements in gesture-production skill should be made with reference to the left cerebral hemisphere disconnection hypothesis.

  2. Mass balance, metabolic disposition, and pharmacokinetics of a single oral dose of regorafenib in healthy human subjects.

    Science.gov (United States)

    Gerisch, Michael; Hafner, Frank-Thorsten; Lang, Dieter; Radtke, Martin; Diefenbach, Konstanze; Cleton, Adriaan; Lettieri, John

    2018-01-01

    To evaluate the mass balance, metabolic disposition, and pharmacokinetics of a single dose of regorafenib in healthy volunteers. In addition, in vitro metabolism of regorafenib in human hepatocytes was investigated. Four healthy male subjects received one 120 mg oral dose of regorafenib containing approximately 100 µCi (3.7 MBq) [ 14 C]regorafenib. Plasma concentrations of parent drug were derived from HPLC-MS/MS analysis and total radioactivity from liquid scintillation counting (LSC). Radiocarbon analyses used HPLC with fraction collection followed by LSC for all urine samples, plasma, and fecal homogenate extracts. For the in vitro study, [ 14 C]regorafenib was incubated with human hepatocytes and analyzed using HPLC-LSC and HPLC-HRMS/MS. Regorafenib was the major component in plasma, while metabolite M-2 (pyridine N-oxide) was the most prominent metabolite. Metabolites M-5 (demethylated pyridine N-oxide) and M-7 (N-glucuronide) were identified as minor plasma components. The mean concentration of total radioactivity in plasma/whole blood appeared to plateau at 1-4 h and again at 6-24 h post-dose. In total, 90.5% of administered radioactivity was recovered in the excreta within a collection interval of 12 days, most of which (71.2%) was eliminated in feces, while excretion via urine accounted for 19.3%. Regorafenib (47.2%) was the most prominent component in feces and was not excreted into urine. Excreted metabolites resulted from oxidative metabolism and glucuronidation. Regorafenib was eliminated predominantly in feces as well as by hepatic biotransformation. The multiple biotransformation pathways of regorafenib decrease the risk of pharmacokinetic drug-drug interactions.

  3. The influence of prototype fidelity and aesthetics of design in usability tests: effects on user behaviour, subjective evaluation and emotion.

    Science.gov (United States)

    Sauer, Juergen; Sonderegger, Andreas

    2009-07-01

    An empirical study examined the impact of prototype fidelity on user behaviour, subjective user evaluation and emotion. The independent factors of prototype fidelity (paper prototype, computer prototype, fully operational appliance) and aesthetics of design (high vs. moderate) were varied in a between-subjects design. The 60 participants of the experiment were asked to complete two typical tasks of mobile phone usage: sending a text message and suppressing a phone number. Both performance data and a number of subjective measures were recorded. The results suggested that task completion time may be overestimated when a computer prototype is being used. Furthermore, users appeared to compensate for deficiencies in aesthetic design by overrating the aesthetic qualities of reduced fidelity prototypes. Finally, user emotions were more positively affected by the operation of the more attractive mobile phone than by the less appealing one.

  4. Longitudinal Seismic Behavior of a Single-Tower Cable-Stayed Bridge Subjected to Near-Field Earthquakes

    Directory of Open Access Journals (Sweden)

    J. Yi

    2017-01-01

    Full Text Available Cable-stayed bridges are quite sensitive to large amplitude oscillations from earthquakes and seismic damage was observed for Shipshaw Bridge and Chi-Lu Bridge during past earthquakes. In order to investigate seismic damage of cable-stayed bridges, a 1 : 20 scale model of a single-tower cable-stayed bridge with A-shaped tower was designed, constructed, and tested on shake tables at Tongji University, China. One typical near-field ground motion was used to excite the model from low to high intensity. Test result showed that severe structural damage occurred at the tower of the model including parallel concrete cracks from bottom to nearly half height of the tower, concrete spalling, and exposed bars at top tower 0.2 m above the section where two skewed legs intersect. Posttest analysis was conducted and compared with test results. It is revealed that the numerical model was able to simulate the seismic damage of the test model by modeling nonlinearity of different components for cable-stayed bridges, namely, the tower, bents, superstructure, cables, and bearings. Numerical analysis also revealed that cable relaxation, which was detected during the test, had limited influence on the overall seismic response of the bridge with maximum error of 12%.

  5. Multi-person and multi-attribute design evaluations using evidential reasoning based on subjective safety and cost analyses

    International Nuclear Information System (INIS)

    Wang, J.; Yang, J.B.; Sen, P.

    1996-01-01

    This paper presents an approach for ranking proposed design options based on subjective safety and cost analyses. Hierarchical system safety analysis is carried out using fuzzy sets and evidential reasoning. This involves safety modelling by fuzzy sets at the bottom level of a hierarchy and safety synthesis by evidential reasoning at higher levels. Fuzzy sets are also used to model the cost incurred for each design option. An evidential reasoning approach is then employed to synthesise the estimates of safety and cost, which are made by multiple designers. The developed approach is capable of dealing with problems of multiple designers, multiple attributes and multiple design options to select the best design. Finally, a practical engineering example is presented to demonstrate the proposed multi-person and multi-attribute design selection approach

  6. Masked Visual Analysis: Minimizing Type I Error in Visually Guided Single-Case Design for Communication Disorders.

    Science.gov (United States)

    Byun, Tara McAllister; Hitchcock, Elaine R; Ferron, John

    2017-06-10

    Single-case experimental designs are widely used to study interventions for communication disorders. Traditionally, single-case experiments follow a response-guided approach, where design decisions during the study are based on participants' observed patterns of behavior. However, this approach has been criticized for its high rate of Type I error. In masked visual analysis (MVA), response-guided decisions are made by a researcher who is blinded to participants' identities and treatment assignments. MVA also makes it possible to conduct a hypothesis test assessing the significance of treatment effects. This tutorial describes the principles of MVA, including both how experiments can be set up and how results can be used for hypothesis testing. We then report a case study showing how MVA was deployed in a multiple-baseline across-subjects study investigating treatment for residual errors affecting rhotics. Strengths and weaknesses of MVA are discussed. Given their important role in the evidence base that informs clinical decision making, it is critical for single-case experimental studies to be conducted in a way that allows researchers to draw valid inferences. As a method that can increase the rigor of single-case studies while preserving the benefits of a response-guided approach, MVA warrants expanded attention from researchers in communication disorders.

  7. Design and cold-air test of single-stage uncooled turbine with high work output

    Science.gov (United States)

    Moffitt, T. P.; Szanca, E. M.; Whitney, W. J.; Behning, F. P.

    1980-01-01

    A solid version of a 50.8 cm single stage core turbine designed for high temperature was tested in cold air over a range of speed and pressure ratio. Design equivalent specific work was 76.84 J/g at an engine turbine tip speed of 579.1 m/sec. At design speed and pressure ratio, the total efficiency of the turbine was 88.6 percent, which is 0.6 point lower than the design value of 89.2 percent. The corresponding mass flow was 4.0 percent greater than design.

  8. Soothing and anti-itch effect of quercetin phytosome in human subjects: a single-blind study

    Directory of Open Access Journals (Sweden)

    Maramaldi G

    2016-02-01

    Full Text Available Giada Maramaldi,1 Stefano Togni,1 Ivan Pagin,1 Luca Giacomelli,2 Roberta Cattaneo,3 Roberto Eggenhöffner,2 Samuele E Burastero4 1Indena S.p.A, Milan, 2Department of Surgical Sciences and Integrated Diagnostics, School of Medicine, Genova University, Genoa, 3Abich Srl, Verbania, 4San Raffaele Scientific Institute, Milan, ItalyBackground: We evaluated the ability of quercetin, a natural antioxidant formulated in a specific delivery system, to reduce skin inflammation induced by a variety of stimuli, including UV radiation, stimulation with a histamine solution, or contact with chemical irritants. In particular, we tested the soothing and anti-itch effect of Quercevita®, 1% cream for external use, a formulation characterized by a phospholipids-based delivery system.Patients and methods: The study was a monocentric, single blind trial that enrolled a group of 30 healthy volunteers. The back of each subject was examined to identify four quadrants with no previous skin damage or naevi that were treated in order to induce a controlled and reversible form of skin stress. The areas were treated as follows: no product; Quercevita® 1% cream, 2 mg/cm2; placebo; positive control (a commercially available topical formulation containing 1% dexchlorpheniramine.Results: Only quercetin phospholipids 1% and dexchlorpheniramine 1% achieved a significant reduction in erythema with comparable results: (–10.05% [P=0.00329] for quercetin phospholipids 1% vs –14.05% [P=0.00046] for the positive control. Moreover, quercetin phospholipids 1% and dexchlorpheniramine 1% were both associated with a significant decrease in mean wheal diameter: (–13.25% and –12.23% for dexchlorpheniramine 1%, respectively. Similar findings were reported for the other tested parameters.Conclusion: Quercetin has a skin protective effect against damage caused by a variety of insults, including UV radiation, histamine, or contact with toxic chemical compounds. Indeed, quercetin is able

  9. Effects of diazepam and levodopa single doses on motor cortex plasticity modulation in healthy human subjects: A TMS study

    Directory of Open Access Journals (Sweden)

    Ilić Nela V.

    2012-01-01

    Full Text Available Introduction. Administration of pharmacological agents with specific actions on neurotransmitter systems is a powerful driver of functional cortical reorganization. Plastic reorganization of the motor cortex in humans studies by the use of non-invasive stimulation protocols, which mimic the Hebbian model of associative plasticity. Objective. Aiming to explore pharmacological modulation on human motor cortex plasticity, we tested healthy subjects after each dosage of diazepam, levodopa i placebo administration, using paired associative stimulation protocol (PAS that induce fenomena similar to a long-term potentiation and depression, as defined on the synaptic level. Methods. We analyzed effects of benzodiazepines (10 mg, levodopa (200 mg and placebo on PAS protocol in 14 healthy volunteers, using a double-blind placebo-controlled study design. PAS consisted of electrical stimuli pairs at n.medianus and magnetic pulses over the scalp (transcranial magnetic stimulation in precisely defined intervals (ISI was 10 and 25 ms for a total of about 15 minutes (200 pairs. MEP amplitudes before and after (0, 10, 20 and 30 minutes later interventional protocols were compared. Results. When protocols were applied with placebo depending on ISI (10 ms - inhibitory, 25 ms - facilitatory effects, MEP amplitudes decreased or increased, while values in the postinterventional period (0, 10, 20 and 30 min were compared with initial values before the use of SAS. The use of benzodiazepines caused the occlusion of LTP-like effect, in contrast to amplification effects recorded after the administration of levodopa. With respect to the LTD-like protocol, the reverse was true (ANOVA for repeat measurements p<0.001. Conclusion. Administration of GABA-ergic agonist diazepam interferes with the induction of associative plasticity in the motor cortex of healthy individuals, as opposed to the use of levodopa, which stimulates these processes. The observed effects point at a

  10. Hybrid neural network model for the design of beam subjected to ...

    Indian Academy of Sciences (India)

    There is no direct method for design of beams. In general the dimensions of the beam and reinforcement are initially assumed and then the interaction formula is used to verify the suitability of chosen dimensions. This approach necessitates few trials for coming up with an economical and safe design. This paper ...

  11. On strength design using free material subjected to multiple load cases

    DEFF Research Database (Denmark)

    Pedersen, Pauli; Pedersen, Niels Leergaard

    2013-01-01

    Multiple load cases and the consideration of strength is a reality that most structural designs are exposed to. Improved possibility to produce specific materials, say by fiber lay-up, put focus on research on free material optimization. A formulation for such design problems together with a prac......Multiple load cases and the consideration of strength is a reality that most structural designs are exposed to. Improved possibility to produce specific materials, say by fiber lay-up, put focus on research on free material optimization. A formulation for such design problems together...... with a practical recursive design procedure is presented and illustrated with examples. The presented finite element analysis involve many elements as well as many load cases. Separating the local amount of material from a description with unit trace for the local anisotropy, gives the free materials formulation...

  12. Design of climate respiration chambers, adjustable to the metabolic mass of subjects

    NARCIS (Netherlands)

    Heetkamp, M.J.W.; Alferink, S.J.J.; Zandstra, T.; Hendriks, P.; Brand, van den H.; Gerrits, W.J.J.

    2015-01-01

    Open-circuit respiration chambers can be used to measure gas exchange and to calculate heat production (Q) of humans and animals. When studying short-term changes in Q, the size of the respiration chamber in relation to the subject of study is a point of concern. The washout time of a chamber,

  13. Predicting Rapid Relapse Following Treatment for Chemical Dependence: A Matched-Subjects Design.

    Science.gov (United States)

    Svanum, Soren; McAdoo, William George

    1989-01-01

    Persons who underwent residential treatment for chemical dependency were identified as three-month treatment failures (N=52) or successes (N=52). Subjects were matched on Minnesota Multiphasic Personality Inventory (MMPI) scores. Found posttreatment depression, anxiety, and sleep problems strongly related to failure among psychiatric MMPI group;…

  14. Design of a bolted flange subjected to severe nuclear system thermal transients - A case study

    International Nuclear Information System (INIS)

    Palmer, W.J.; Tomawski, R.J.; Ezekoye, L.I.; Lacey, M.L.

    1986-01-01

    Flange design standards recognize that flanged joints may develop leakage should they be exposed to severe thermal gradients and recommend that such operating conditions be avoided. In nuclear power plants, severe thermal transients may be encountered in many plant and system operating and test conditions. In such applications, conformance with standard design practice may not ensure a leak-tight joint. This paper describes the proper consideration of thermal effects on flanged joints and how that can lead to the development of a successful leak-tight design. Similar procedures may be applied generally to evaluate and upgrade flanged joints in thermal shock applications

  15. Designing oversight for nanomedicine research in human subjects: systematic analysis of exceptional oversight for emerging technologies

    International Nuclear Information System (INIS)

    Wolf, Susan M.; Jones, Cortney M.

    2011-01-01

    The basic procedures and rules for oversight of U.S. human subjects research have been in place since 1981. Certain types of human subjects research, however, have provoked creation of additional mechanisms and rules beyond the Department of Health and Human Services (DHHS) Common Rule and Food and Drug Administration (FDA) equivalent. Now another emerging domain of human subjects research—nanomedicine—is prompting calls for extra oversight. However, in 30 years of overseeing research on human beings, we have yet to specify what makes a domain of scientific research warrant extra oversight. This failure to systematically evaluate the need for extra measures, the type of extra measures appropriate for different challenges, and the usefulness of those measures hampers efforts to respond appropriately to emerging science such as nanomedicine. This article evaluates the history of extra oversight, extracting lessons for oversight of nanomedicine research in human beings. We argue that a confluence of factors supports the need for extra oversight, including heightened uncertainty regarding risks, fast-evolving science yielding complex and increasingly active materials, likelihood of research on vulnerable participants including cancer patients, and potential risks to others beyond the research participant. We suggest the essential elements of the extra oversight needed.

  16. Designing oversight for nanomedicine research in human subjects: systematic analysis of exceptional oversight for emerging technologies

    Science.gov (United States)

    Wolf, Susan M.; Jones, Cortney M.

    2011-04-01

    The basic procedures and rules for oversight of U.S. human subjects research have been in place since 1981. Certain types of human subjects research, however, have provoked creation of additional mechanisms and rules beyond the Department of Health & Human Services (DHHS) Common Rule and Food and Drug Administration (FDA) equivalent. Now another emerging domain of human subjects research—nanomedicine—is prompting calls for extra oversight. However, in 30 years of overseeing research on human beings, we have yet to specify what makes a domain of scientific research warrant extra oversight. This failure to systematically evaluate the need for extra measures, the type of extra measures appropriate for different challenges, and the usefulness of those measures hampers efforts to respond appropriately to emerging science such as nanomedicine. This article evaluates the history of extra oversight, extracting lessons for oversight of nanomedicine research in human beings. We argue that a confluence of factors supports the need for extra oversight, including heightened uncertainty regarding risks, fast-evolving science yielding complex and increasingly active materials, likelihood of research on vulnerable participants including cancer patients, and potential risks to others beyond the research participant. We suggest the essential elements of the extra oversight needed.

  17. Safety and pharmacokinetics of single and multiple intravenous bolus doses of diclofenac sodium compared with oral diclofenac potassium 50 mg: A randomized, parallel-group, single-center study in healthy subjects.

    Science.gov (United States)

    Munjal, Sagar; Gautam, Anirudh; Okumu, Franklin; McDowell, James; Allenby, Kent

    2016-01-01

    In a randomized, parallel-group, single-center study in 42 healthy adults, the safety and pharmacokinetic parameters of an intravenous formulation of 18.75 and 37.5 mg diclofenac sodium (DFP-08) following single- and multiple-dose bolus administration were compared with diclofenac potassium 50 mg oral tablets. Mean AUC0-inf values for a 50-mg oral tablet and an 18.75-mg intravenous formulation were similar (1308.9 [393.0]) vs 1232.4 [147.6]). As measured by the AUC, DFP-08 18.75 mg and 37.5 mg demonstrated dose proportionality for extent of exposure. One subject in each of the placebo and DFP-08 18.75-mg groups and 2 subjects in the DFP-08 37.5-mg group reported adverse events that were considered by the investigator to be related to the study drug. All were mild in intensity and did not require treatment. Two subjects in the placebo group and 1 subject in the DFP-08 18.75-mg group reported grade 1 thrombophlebitis; no subjects reported higher than grade 1 thrombophlebitis after receiving a single intravenous dose. The 18.75- and 37.5-mg doses of intravenous diclofenac (single and multiple) were well tolerated for 7 days. Additional efficacy and safety studies are required to fully characterize the product. © 2015, The American College of Clinical Pharmacology.

  18. Functional aspects of treatment with implant-supported single crowns: a quality control study in subjects with tooth agenesis

    DEFF Research Database (Denmark)

    Goshima, Kenichi; Lexner, Michala O; Thomsen, Carsten Eckhart

    2010-01-01

    -Related Quality of Life (OHRQoL) in subjects with tooth agenesis. MATERIAL AND METHODS: In nine females and nine males (32 + or - 10 years) with agenesis treated with one to four ISSC (68% in the premolar region), the treatment effect and masticatory function were assessed. The evaluation was performed first...... after implant placement shortly before crown cementation, and again 1 month after cementation. It consisted of questionnaires [including Oral Health Impact Profile (OHIP-49)] and functional examination with plastic strips, the Dental Prescale Film and the Occluzer system, Xylitol color-changeable gum...... with ISSCs in subjects with tooth agenesis significantly increased masticatory function subjectively and clinically as well as OHRQoL. However, as the functional parameters before replacement of the teeth corresponded to values in subjects with complete dentitions, the functional importance of the increase...

  19. Design methodology of single-feed compact near-isotropic antenna design

    KAUST Repository

    Su, Zhen

    2017-06-07

    The abundance of mobile wireless devices is giving rise to a new paradigm known as Internet of Things. In this paradigm, wireless devices will be everywhere and communicating with each other. Since they will be oriented randomly in the environment, they should be able to communicate equally in all directions in order to have stable communication link. Hence, compact near isotropic antennas are required, which can enable orientation insensitive communication. In this paper, we propose a simple design methodology to design a compact near-isotropic wire antenna based on equal vector potentials. As a proof of concept, a quarter wavelength monopole antennas has been designed that is wrapped on a 3D-printed box keeping the vector potentials in three orthogonal different directions equal. By optimizing the dimension of the antenna arms, a nearly isotropic radiation pattern is thus achieved. The results show that the antenna has a maximum gain of 2.2dBi at 900 MHz with gain derivation of 9.4dB.

  20. Design and evaluation guidelines for Department of Energy facilities subjected to natural phenomena hazards

    International Nuclear Information System (INIS)

    Kennedy, R.P.; Short, S.A.; McDonald, J.R.; McCann, M.W. Jr.; Murray, R.C.; Hill, J.R.

    1990-06-01

    The Department of Energy (DOE) and the DOE Natural Phenomena Hazards Panel have developed uniform design and evaluation guidelines for protection against natural phenomena hazards at DOE sites throughout the United States. The goal of the guidelines is to assure that DOE facilities can withstand the effects of natural phenomena such as earthquakes, extreme winds, tornadoes, and flooding. The guidelines apply to both new facilities (design) and existing facilities (evaluation, modification, and upgrading). The intended audience is primarily the civil/structural or mechanical engineers conducting the design or evaluation of DOE facilities. The likelihood of occurrence of natural phenomena hazards at each DOE site has been evaluated by the DOE Natural Phenomena Hazard Program. Probabilistic hazard models are available for earthquake, extreme wind/tornado, and flood. Alternatively, site organizations are encouraged to develop site-specific hazard models utilizing the most recent information and techniques available. In this document, performance goals and natural hazard levels are expressed in probabilistic terms, and design and evaluation procedures are presented in deterministic terms. Design/evaluation procedures conform closely to common standard practices so that the procedures will be easily understood by most engineers. Performance goals are expressed in terms of structure or equipment damage to the extent that: (1) the facility cannot function; (2) the facility would need to be replaced; or (3) personnel are endangered. 82 refs., 12 figs., 18 tabs

  1. Design and evaluation guidelines for Department of Energy facilities subjected to natural phenomena hazards

    Energy Technology Data Exchange (ETDEWEB)

    Kennedy, R.P. (Structural Mechanics Consulting, Inc., Yorba Linda, CA (USA)); Short, S.A. (ABB Impell Corp., Mission Viejo, CA (USA)); McDonald, J.R. (Texas Tech Univ., Lubbock, TX (USA)); McCann, M.W. Jr. (Benjamin (J.R.) and Associates, Inc., Mountain View, CA (USA)); Murray, R.C. (Lawrence Livermore National Lab., CA (USA)); Hill, J.R. (USDOE Assistant Secretary for Environment, Safety, and He

    1990-06-01

    The Department of Energy (DOE) and the DOE Natural Phenomena Hazards Panel have developed uniform design and evaluation guidelines for protection against natural phenomena hazards at DOE sites throughout the United States. The goal of the guidelines is to assure that DOE facilities can withstand the effects of natural phenomena such as earthquakes, extreme winds, tornadoes, and flooding. The guidelines apply to both new facilities (design) and existing facilities (evaluation, modification, and upgrading). The intended audience is primarily the civil/structural or mechanical engineers conducting the design or evaluation of DOE facilities. The likelihood of occurrence of natural phenomena hazards at each DOE site has been evaluated by the DOE Natural Phenomena Hazard Program. Probabilistic hazard models are available for earthquake, extreme wind/tornado, and flood. Alternatively, site organizations are encouraged to develop site-specific hazard models utilizing the most recent information and techniques available. In this document, performance goals and natural hazard levels are expressed in probabilistic terms, and design and evaluation procedures are presented in deterministic terms. Design/evaluation procedures conform closely to common standard practices so that the procedures will be easily understood by most engineers. Performance goals are expressed in terms of structure or equipment damage to the extent that: (1) the facility cannot function; (2) the facility would need to be replaced; or (3) personnel are endangered. 82 refs., 12 figs., 18 tabs.

  2. Enhancing the hermeneutic single-case efficacy design: Bridging the research-practice gap.

    Science.gov (United States)

    Wall, Jessie M; Kwee, Janelle L; Hu, Monica; McDonald, Marvin J

    2017-09-01

    Systematic case study designs are emerging as alternative paradigm strategies for psychotherapy and social science research. Through enhanced sensitivity to context, these designs examine idiographic profiles of causal processes. We specifically advocate the use of the hermeneutic single-case efficacy design (HSCED). HSCED has recently been used to investigate the efficacy of an existing therapy with a new population (Observed and Experiential Integration for athlete performance barriers) and an emerging therapy (Lifespan Integration Therapy). We describe innovations in HSCED that were implemented for these studies. These developments include (a) integrating psychotherapists as case developers, (b) incorporating multiple cases in one investigation, and (c) tailoring the repertoire of assessment tools. These extensions strategically incorporated principles of contextual paradigms in HSCED, thus complementing single-case designs that neglect idiographic contexts. We discuss recommendations for using HSCED in practice-based research, highlighting its potential as a bridge to address the research-practice gap.

  3. A parametric design of ceramic faced composite armor subject to air weapon threats

    International Nuclear Information System (INIS)

    Guo, Y N; Sun, Q

    2015-01-01

    By taking into consideration the two categories of military projectile threats to aircraft structures, an optimal layer configuration of ceramic faced composite armor was designed in this paper. Using numerical simulations and the same layer arrangement of ceramic, UHMWPE, and carbon fiber laminates, a parametric finite element model using LS-DYNA code was built. Several thickness combinations were analyzed in order to determine the final lightest configuration that is capable of supporting a high-speed impact load and HEI blast wave load, which implements a high anti-penetration design for aircraft armor. This configuration can be used to improve the anti-impact ability of aircraft structures as well as achieve a structure/function integration design that considers a lighter weight. (paper)

  4. Design of Robust AMB Controllers for Rotors Subjected to Varying and Uncertain Seal Forces

    DEFF Research Database (Denmark)

    Lauridsen, Jonas Skjødt; Santos, Ilmar

    2017-01-01

    This paper demonstrates the design and simulation results of model based controllers for AMB systems, subjectedto uncertain and changing dynamic seal forces. Specifically, a turbocharger with a hole-pattern seal mounted acrossthe balance piston is considered. The dynamic forces of the seal, which...... are dependent on the operational conditions,have a significant effect on the overall system dynamics. Furthermore, these forces are considered uncertain.The nominal and the uncertainty representation of the seal model are established using results from conventionalmodelling approaches, i.e. CFD and Bulkflow......, and experimental results. Three controllers are synthesized: I) AnH∞ controller based on nominal plant representation, II) A µ controller, designed to be robust against uncertaintiesin the dynamic seal model and III) a Linear Parameter Varying (LPV) controller, designed to provide a unifiedperformance over a large...

  5. Balancing between conflicting values for designing subjective well-being for the digital home

    NARCIS (Netherlands)

    Tsai, W.-C.; Chuang, Y.; Chen, L.

    2015-01-01

    This paper highlights three pairs of implicit but important human values that are sometimes overlooked or taken for granted in the design of mainstream products for the home. They are private and shared, present and past, control and abdicate. We argue that these values are worth preserving and

  6. A Comparison of Different Teaching Designs of "Acids and Bases" Subject

    Science.gov (United States)

    Ültay, Neslihan; Çalik, Muammer

    2016-01-01

    Inability to link the acid-base concepts with daily life phenomena (as contexts) highlights the need for further research on the context-based acid-base chemistry. In this vein, the aim of this study is to investigate the effects of different teaching designs (REACT strategy, 5Es learning model and traditional (existing) instruction) relevant with…

  7. Feasibility studies on design of steel containment for AHWR subjected to normal and seismic loads

    International Nuclear Information System (INIS)

    Verma, Rajeev; Reddy, G.R.; Vaze, K.K.; Kumar, Ajay

    2011-01-01

    Reactor Containments in nuclear power plants are the final leak tight harriers preventing release of radioactive material during the accident to the environment. It should provide containment against fission product release, passive containment cooling and should be economical. In the world various configurations have been adopted depending on the accident pressures, temperatures, leak rate requirements and radius of exclusion zones. economy, speed of construction etc. Some of the containments arc of Reinforced Cement Concrete (RCC), Prestressed Cement Concrete (PCC), RCC with the liner, PCC with the liner and Steel. The design concepts and the choice of containment depend on the country practices. The main objective of this paper is to design, analyze and characterize the effectiveness of steel containment for AHWR and compare it with other type of containments. The paper discusses the literature regarding various types of existing containments in the world. In depth study of design practice for cylinder and various types of heads have been discussed. Also discusses the finite element modeling of the containment, analysis for normal and accidental loads and the design qualification as per the ASME and IS-800 codes. In the conclusion the advantage of steel containment is highlighted with the small discussion on the newer trends of construction. (author)

  8. Single-Case Research Design: An Alternative Strategy for Evidence-Based Practice

    Science.gov (United States)

    Stapleton, Drue; Hawkins, Andrew

    2015-01-01

    Objective: The trend of utilizing evidence-based practice (EBP) in athletic training is now requiring clinicians, researchers, educators, and students to be equipped to both engage in and make judgments about research evidence. Single-case design (SCD) research may provide an alternative approach to develop such skills and inform clinical and…

  9. Applying Quality Indicators to Single-Case Research Designs Used in Special Education: A Systematic Review

    Science.gov (United States)

    Moeller, Jeremy D.; Dattilo, John; Rusch, Frank

    2015-01-01

    This study examined how specific guidelines and heuristics have been used to identify methodological rigor associated with single-case research designs based on quality indicators developed by Horner et al. Specifically, this article describes how literature reviews have applied Horner et al.'s quality indicators and evidence-based criteria.…

  10. Publishing Single-Case Research Design Studies That Do Not Demonstrate Experimental Control

    Science.gov (United States)

    Tincani, Matt; Travers, Jason

    2018-01-01

    Demonstration of experimental control is considered a hallmark of high-quality single-case research design (SCRD). Studies that fail to demonstrate experimental control may not be published because researchers are unwilling to submit these papers for publication and journals are unlikely to publish negative results (i.e., the file drawer effect).…

  11. ADHD Symptom Reduction in Elementary Students: A Single-Case Effectiveness Design

    Science.gov (United States)

    Schottelkorb, April A.; Ray, Dee C.

    2009-01-01

    The authors used a single-case design to examine the effectiveness of child-centered play therapy (CCPT) and person-centered teacher consultation (PCTC) for four elementary students identified with attention deficit hyperactivity disorder (ADHD) symptoms. Two students participated in CCPT and their teachers participated in PCTC. Two students…

  12. Using Data Collection Apps and Single-Case Designs to Research Transformative Learning in Adults

    Science.gov (United States)

    Roessger, Kevin M.; Greenleaf, Arie; Hoggan, Chad

    2017-01-01

    To overcome situational hurdles when researching transformative learning in adults, we outline a research approach using single-case research designs and smartphone data collection apps. This approach allows researchers to better understand learners' current lived experiences and determine the effects of transformative learning interventions on…

  13. Anterior single implants with different neck designs : 5 Year results of a randomized clinical trial

    NARCIS (Netherlands)

    den Hartog, Laurens; Meijer, Henny J A; Vissink, Arjan; Raghoebar, Gerry M

    BACKGROUND: The design of the implant neck might be significant for preservation of marginal bone. PURPOSE: To compare the 5-year radiographic and clinical outcome of single anterior implants provided with a smooth neck, a rough neck or a scalloped rough neck. MATERIALS AND METHODS: 93 Patients with

  14. Therapist-Aided Exposure for Women with Lifelong Vaginismus: A Replicated Single-Case Design

    Science.gov (United States)

    ter Kuile, Moniek M.; Bulte, Isis; Weijenborg, Philomeen T. M.; Beekman, Aart; Melles, Reinhilde; Onghena, Patrick

    2009-01-01

    Vaginismus is commonly described as a persistent difficulty in allowing vaginal entry of a penis or other object. Lifelong vaginismus occurs when a woman has never been able to have intercourse. A replicated single-case A-B-phase design was used to investigate the effectiveness of therapist-aided exposure for lifelong vaginismus. A baseline period…

  15. Design of Water Temperature Control System Based on Single Chip Microcomputer

    Science.gov (United States)

    Tan, Hanhong; Yan, Qiyan

    2017-12-01

    In this paper, we mainly introduce a multi-function water temperature controller designed with 51 single-chip microcomputer. This controller has automatic and manual water, set the water temperature, real-time display of water and temperature and alarm function, and has a simple structure, high reliability, low cost. The current water temperature controller on the market basically use bimetal temperature control, temperature control accuracy is low, poor reliability, a single function. With the development of microelectronics technology, monolithic microprocessor function is increasing, the price is low, in all aspects of widely used. In the water temperature controller in the application of single-chip, with a simple design, high reliability, easy to expand the advantages of the function. Is based on the appeal background, so this paper focuses on the temperature controller in the intelligent control of the discussion.

  16. Displacement based seismic design of symmetric single-storey wood-frame buildings with the aid of N2 method

    Directory of Open Access Journals (Sweden)

    Panagiotis eMergos

    2015-07-01

    Full Text Available This paper presents a new methodology for the displacement-based seismic design of symmetric single-storey wood-frame buildings. Previous displacement-based design efforts were based on the direct displacement-based design (DDBD approach, which uses a substitute linear system with an appropriate stiffness and viscous damping combination. Despite the fact that this method has shown to produce promising results for wood structures, it does not fit into the framework of the Eurocode 8 (EC8 provisions. The methodology presented herein is based on the N2 method, which is incorporated in EC8 and combines the non-linear pushover analysis with the response spectrum method. The N2 method has been mostly applied to reinforced concrete and steel structures. In order to properly implement the N2 method for the case of wood-frame buildings new behavior factor – displacement ductility relationships are proposed. These relationships were derived from inelastic time history analyses of 35 SDOF systems subjected to 80 different ground motion records. Furthermore, the validity of the N2 method is examined for the case of a timber shear wall tested on a shake table and satisfactory predictions are obtained. Last, the proposed design methodology is applied to the displacement-based seismic design of a realistic symmetric single-storey wood-frame building in order to meet the performance objectives of EC8. It is concluded that the simplicity and computational efficiency of the adopted methodology make it a valuable tool for the seismic design of this category of wood-frame buildings, while the need for extending the method to more complex wood-frame buildings is also highlighted.

  17. An Improved Rank Correlation Effect Size Statistic for Single-Case Designs: Baseline Corrected Tau.

    Science.gov (United States)

    Tarlow, Kevin R

    2017-07-01

    Measuring treatment effects when an individual's pretreatment performance is improving poses a challenge for single-case experimental designs. It may be difficult to determine whether improvement is due to the treatment or due to the preexisting baseline trend. Tau- U is a popular single-case effect size statistic that purports to control for baseline trend. However, despite its strengths, Tau- U has substantial limitations: Its values are inflated and not bound between -1 and +1, it cannot be visually graphed, and its relatively weak method of trend control leads to unacceptable levels of Type I error wherein ineffective treatments appear effective. An improved effect size statistic based on rank correlation and robust regression, Baseline Corrected Tau, is proposed and field-tested with both published and simulated single-case time series. A web-based calculator for Baseline Corrected Tau is also introduced for use by single-case investigators.

  18. Radiation field control at the latest BWR plants -- design principle, operational experience and future subjects

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, Shunsuke [Energy Research Lab., Ibaraki (Japan); Ohsumi, Katsumi; Takashima, Yoshie [Hitachi Works, Ibaraki (Japan)

    1995-03-01

    Improvements of operational procedures to control water chemistry, e.g., nickel/iron control, as well as application of hardware improvements for reducing radioactive corrosion products resulted in an extremely low occupational exposure of less than 0.5 man.Sv/yr without any serious impact on the radwaste system, for BWR plants involved in the Japanese Improvement and Standardization Program. Recently, {sup 60}C radioactively in the reactor water has been increasing due to less crud fixation on the two smooth surfaces of new type high performance fuels and to the pH drop caused by chromium oxide anions released from stainless steel structures and pipings. This increase must be limited by changes in water chemistry, e.g., applications of modified nickel/iron ratio control and weak alkali control. Controlled water chemistry to optimize three points, the plant radiation level and integrities of fuel and structural materials, is the primary future subject for BWR water chemistry.

  19. CONCRETE MIX DESIGN FOR STRUCTURES SUBJECTED TO EXPOSURE CLASS XC1 DEPENDING ON CONCRETE COVER

    Directory of Open Access Journals (Sweden)

    O. Yu. Cherniakevich

    2016-01-01

    Full Text Available The reinforced steel corrosion which is the most important problem of reinforced concrete structures durability is generally stipulated for carbonization of concrete surrounding it. Concrete cover calculation at the design stage is predicated one because of the differences in manufacturing conditions and use of constructions. The applying of the probabilistic approaches to the carbonation process modeling allows to get predicated grade of the depth of carbonization of concrete and, thus, to settle minimum concrete cover thickness for a given projected service life of a construction. The procedures for concrete mix design for different strength classes of concrete are described in the article. Current recommendations on assignment of concrete strength class as well as concrete cover are presented. The European Standard EN 206:2013 defines the content requirements for the concrete structures operated in the exposure class XC1, including the minimum values of water-cement ratio, minimum cement content, and minimum strength class of concrete. Since the standard does not include any basis or explanations of the requirements, we made an effort to develop a scientific justification for the mentioned requirements. We developed the probabilistic models for the process of carbonation of concrete based on the concrete mix which was designed using the software VTK-Korroziya. The reinforced concrete structures with concrete cover 20–35 mm operated in the most unfavorable conditions within the exposure class XC1 were analyzed. The corresponding probabilistic calculations of the depth of carbonated concrete are described in the article. 

  20. Assessment of precast beam-column using capacity demand response spectrum subject to design basis earthquake and maximum considered earthquake

    Science.gov (United States)

    Ghani, Kay Dora Abd.; Tukiar, Mohd Azuan; Hamid, Nor Hayati Abdul

    2017-08-01

    Malaysia is surrounded by the tectonic feature of the Sumatera area which consists of two seismically active inter-plate boundaries, namely the Indo-Australian and the Eurasian Plates on the west and the Philippine Plates on the east. Hence, Malaysia experiences tremors from far distant earthquake occurring in Banda Aceh, Nias Island, Padang and other parts of Sumatera Indonesia. In order to predict the safety of precast buildings in Malaysia under near field ground motion the response spectrum analysis could be used for dealing with future earthquake whose specific nature is unknown. This paper aimed to develop of capacity demand response spectrum subject to Design Basis Earthquake (DBE) and Maximum Considered Earthquake (MCE) in order to assess the performance of precast beam column joint. From the capacity-demand response spectrum analysis, it can be concluded that the precast beam-column joints would not survive when subjected to earthquake excitation with surface-wave magnitude, Mw, of more than 5.5 Scale Richter (Type 1 spectra). This means that the beam-column joint which was designed using the current code of practice (BS8110) would be severely damaged when subjected to high earthquake excitation. The capacity-demand response spectrum analysis also shows that the precast beam-column joints in the prototype studied would be severely damaged when subjected to Maximum Considered Earthquake (MCE) with PGA=0.22g having a surface-wave magnitude of more than 5.5 Scale Richter, or Type 1 spectra.

  1. A single night of partial sleep deprivation induces insulin resistance in multiple metabolic pathways in healthy subjects

    NARCIS (Netherlands)

    Donga, Esther; van Dijk, Marieke [Leiden Univ., LUMC; van Dijk, J. Gert; Biermasz, Nienke R.; Lammers, Gert-Jan; van Kralingen, Klaas W.; Corssmit, Eleonara P. M.; Romijn, Johannes A.

    2010-01-01

    Subsequent nights with partial sleep restriction result in impaired glucose tolerance, but the effects on insulin sensitivity have not been characterized. The aim of this study was to evaluate the effect of a single night of partial sleep restriction on parameters of insulin sensitivity. Nine

  2. The Effectiveness of a Single Intervention of Computer-Aided Argument Mapping in a Marketing and a Financial Accounting Subject

    Science.gov (United States)

    Carrington, Michal; Chen, Richard; Davies, Martin; Kaur, Jagjit; Neville, Benjamin

    2011-01-01

    An argument map visually represents the structure of an argument, outlining its informal logical connections and informing judgments as to its worthiness. Argument mapping can be augmented with dedicated software that aids the mapping process. Empirical evidence suggests that semester-length subjects using argument mapping along with dedicated…

  3. A Single Session of Autogenic Training Increases Acute Subjective and Physiological Sexual Arousal in Sexually Functional Women.

    Science.gov (United States)

    Stanton, Amelia; Meston, Cindy

    2017-10-03

    Heart rate variability (HRV) has recently been associated with female sexual function (Stanton, Lorenz, Pulverman, & Meston, 2015). Below-average HRV was identified as a possible risk factor for sexual arousal dysfunction and overall sexual dysfunction in women. Based on this newly established relationship between HRV and female sexual function, the present study examined the effect of autogenic training to increase HRV on acute physiological and subjective sexual arousal in women. Specifically, vaginal pulse amplitude (VPA), an index of genital sexual arousal, and subjective sexual arousal were assessed in 33 sexually functional women, aged 18 to 27, before and after a short session of autogenic training. Autogenic training, a relaxation technique that restores the balance between the activity of the sympathetic and the parasympathetic branches of the autonomic nervous system, has been shown to significantly increase HRV (Miu, Heilman, & Miclea, 2009). After autogenic training, significant increases in both VPA (p <.05) and subjective sexual arousal (p <.005) were observed. Moreover, change in HRV from pre- to postmanipulation significantly moderated changes in subjective sexual arousal (p <.05) when it was measured continuously during the presentation of the erotic stimulus. This cost-effective, easy-to-administer behavioral intervention may have important implications for increasing sexual arousal in women.

  4. Motion Control Design for an Omnidirectional Mobile Robot Subject to Velocity Constraints

    Directory of Open Access Journals (Sweden)

    Ollin Peñaloza-Mejía

    2015-01-01

    Full Text Available A solution to achieve global asymptotic tracking with bounded velocities in an omnidirectional mobile robot is proposed in this paper. It is motivated by the need of having a useful in-practice motion control scheme, which takes into account the physical limits of the velocities. To this end, a passive nonlinear controller is designed and combined with a tracking controller in a negative feedback connection structure. By using Lyapunov theory and passivity tools, global asymptotic tracking with desired bounded velocities is proved. Simulations and experimental results are provided to show the effectiveness of the proposal.

  5. Device Design and Test of Fatigue Behaviour of Expansion Anchor Subjected to Tensile Loads

    Directory of Open Access Journals (Sweden)

    Zhang Jinfeng

    2016-01-01

    Full Text Available In order to study on the fatigue behaviour of expansion anchor (M16, grade 8.8 for overhead contact system in electrification railways, a set of safe, practical loading device is designed and a fatigue test campaign was carried out at structural laboratory of China Academy of Building Research on expansion anchor embedded in concrete block. The mobile frame of the loading device was designed well by finite-element simulation. According to some fatigue performance test of expansion anchor with different size and form, the device have been assessed experimentally its dependability. The results were found that no fatigue damage phenomenon occurred in all specimens after 2×106 cycles tensile fatigue test in this specific series. It shows that in the condition of medium level or slightly lower maximum stress limit and nominal stress range, expansion bolt has good fatigue resistance. The biggest relative displacement and the residual relative displacement after test (Δδ = δ2-δ1 was also strongly lower than the symbol of the fatigue test failure index of this specific series (0.5mm in the high cycle fatigue regime. The ultimate tension failures mode after fatigue tests in all tested samples take place in the concrete anchorage zone. The reduction range of the ultimate tensile strength properties of the anchorage system was not obvious, and the concrete was seen to be the weakest link of the system.

  6. Progress towards developing consistent design and evaluation guidelines for DOE facilities subjected to natural phenomena hazards

    International Nuclear Information System (INIS)

    Kennedy, R.P.; Short, S.A.; McDonald, J.R.; McCann, M.W. Jr.; Reed, J.W.

    1985-01-01

    Probabilistic definitions of earthquake, wind and tornado natural phenomena hazards for many Department of Energy (DOE) facilities throughout the United States have been developed. In addition, definitions of the flood hazards which might affect these locations are currently being developed. The Department of Energy Natural Phenomena Hazards Panel is now preparing a document to provide guidance and criteria for DOE facility managers to assure that DOE facilities are adequately constructed to resist the effects of natural phenomena such as earthquake, strong wind and flood. The intent of this document is to provide instruction on how to utilize the hazard definitions to evaluate existing facilities and design new facilities in a manner such that the risk of adverse consequences is consistent with the cost, function, and danger to the public or environment of the facility. Potential effects on facilities of natural phenomena hazards are emphasized in this paper. The philosophy for mitigating these effects to be employed in the design and evaluation guidelines is also presented

  7. Multi-disciplinary design optimization and performance evaluation of a single stage transonic axial compressor

    International Nuclear Information System (INIS)

    Lee, Sae Il; Lee, Dong Ho; Kim, Kyu Hong; Park, Tae Choon; Lim, Byeung Jun; Kang, Young Seok

    2013-01-01

    The multidisciplinary design optimization method, which integrates aerodynamic performance and structural stability, was utilized in the development of a single-stage transonic axial compressor. An approximation model was created using artificial neural network for global optimization within given ranges of variables and several design constraints. The genetic algorithm was used for the exploration of the Pareto front to find the maximum objective function value. The final design was chosen after a second stage gradient-based optimization process to improve the accuracy of the optimization. To validate the design procedure, numerical simulations and compressor tests were carried out to evaluate the aerodynamic performance and safety factor of the optimized compressor. Comparison between numerical optimal results and experimental data are well matched. The optimum shape of the compressor blade is obtained and compared to the baseline design. The proposed optimization framework improves the aerodynamic efficiency and the safety factor.

  8. Design and optimization of a self-developing single axis tracking PV array

    International Nuclear Information System (INIS)

    Colozza, A.J.

    1992-01-01

    This paper reports on a study performed in order to design a tracking PV array and optimize the design for maximum specific power. The design considerations were minimal deployment time, high reliability and small stowage volume. The array design was self-deployable, from a compact stowage configuration, using a passive pressurized gas deployment mechanism. The array structural components consist of a combination of beams, columns and cables used to deploy and orient a flexible PV blanket. Each structural component of the design was analyzed to determine the size necessary to withstand the various forces it would be subjected to. An optimization was performed to determine the array dimensions and blanket geometry which produce the maximum specific power

  9. Control Design of Active Magnetic Bearings for Rotors Subjected to Destabilising Seal Forces - Theory & Experiment

    DEFF Research Database (Denmark)

    Lauridsen, Jonas Skjødt

    . At present, there is no generally accepted method for determination of dynamic seal forces. Therefore, large uncertainties must be expected when modelling dynamic seal forces and consequently also in rotor-dynamic stability analysis. This thesis focuses on i) closed loop identification of uncertain AMB...... parameters, ii) closed loop identification of unknown stiffness and damping coefficients of a dynamicseal model and iii) the design of AMB controllers to handle dynamic seal forces. Controllers that can guarantee stability and performance in the presence of uncertainseal forces are of special interest...... the uncertaintiesin seal forces and for LPV control synthesis, to compensate for known changes in seal forces due to changes in operating conditions. A rotor dynamic test facility with a rigid rotor, two radial AMBs and one annular test seal is used for i) closed loop identification of parameters in the AMB...

  10. The diuretic effect in human subjects of an extract of Taraxacum officinale folium over a single day.

    Science.gov (United States)

    Clare, Bevin A; Conroy, Richard S; Spelman, Kevin

    2009-08-01

    Taraxacum officinale (L.) Weber (Asteraceae) has been extensively employed as a diuretic in traditional folk medicine and in modern phytotherapy in Europe, Asia, and the Americas without prior clinical trial substantiation. In this pilot study, a high-quality fresh leaf hydroethanolic extract of the medicinal plant T. officinale (dandelion) was ingested by volunteers to investigate whether an increased urinary frequency and volume would result. Volume of urinary output and fluid intake were recorded by subjects. Baseline values for urinary frequency and excretion ratio (urination volume:fluid intake) were established 2 days prior to dandelion dosing (8 mL TID) and monitored throughout a 1-day dosing period and 24 hours postdosing. For the entire population (n = 17) there was a significant (p officinale ethanolic extract shows promise as a diuretic in humans. Further studies are needed to establish the value of this herb for induction of diuresis in human subjects.

  11. Convective heat transfer in single-phase flow in a vertical tube subjected to axial low frequency oscillations

    Energy Technology Data Exchange (ETDEWEB)

    Pendyala, Rajashekhar; Jayanti, Sreenivas; Balakrishnan, A.R. [Indian Institute of Technology Madras, Department of Chemical Engineering, Chennai, Tamil Nadu (India)

    2008-05-15

    The effect of oscillations on the heat transfer in a vertical tube has been studied experimentally. A vertical tube was mounted on a plate and the whole plate was subjected to oscillations in the vertical plane using a mechanical oscillator to provide low frequency oscillations. A section of the tube in the middle is subjected to a constant heat flux. The effect of the oscillations on the heat transfer coefficient has been examined. It was found that the heat transfer coefficient increased with oscillations in the laminar regime. In turbulent flow regime (Re > 2,100) it is found that the effect of oscillations did not show any change. A correlation has been developed for enhancement of the local Nusselt number in terms of the effective acceleration and Reynolds number. Using this, an expression has been proposed to calculate the mean Nusselt number as a function of the tube length. (orig.)

  12. Design considerations for single-stage and two-stage pneumatic pellet injectors

    International Nuclear Information System (INIS)

    Gouge, M.J.; Combs, S.K.; Fisher, P.W.; Milora, S.L.

    1988-09-01

    Performance of single-stage pneumatic pellet injectors is compared with several models for one-dimensional, compressible fluid flow. Agreement is quite good for models that reflect actual breech chamber geometry and incorporate nonideal effects such as gas friction. Several methods of improving the performance of single-stage pneumatic pellet injectors in the near term are outlined. The design and performance of two-stage pneumatic pellet injectors are discussed, and initial data from the two-stage pneumatic pellet injector test facility at Oak Ridge National Laboratory are presented. Finally, a concept for a repeating two-stage pneumatic pellet injector is described. 27 refs., 8 figs., 3 tabs

  13. Assessment of the Pharmacokinetics, Pharmacodynamics, and Safety of Single Doses of TV-1106, a Long-Acting Growth Hormone, in Healthy Japanese and Caucasian Subjects.

    Science.gov (United States)

    Cohen-Barak, Orit; Barkay, Hadas; Rasamoelisolo, Michele; Butler, Kathleen; Yamada, Kazumasa; Bassan, Merav; Yoon, Esther; Spiegelstein, Ofer

    2017-07-01

    TV-1106 is a human serum albumin genetically fused to recombinant human growth hormone, designed to provide a long-acting alternative to daily growth hormone (GH) injections in patients with GH deficiency. This study investigated the pharmacokinetics, pharmacodynamics, and safety of single subcutaneous doses of TV-1106 (7.5, 15, 50, and 100 mg) in Japanese (n = 44) and caucasian (n = 44) healthy subjects. TV-1106 pharmacokinetics and pharmacodynamics were comparable in Japanese and caucasian populations. TV-1106 demonstrated relatively slow absorption (median t max , 10-30 hours) and a mean elimination half-life of 26-36 hours. Apparent clearance and volume of distribution decreased with increasing TV-1106 doses in both populations and appeared to increase more than dose proportionality across the tested doses. Insulin-like growth factor-1 (IGF-1) and IGF binding protein-3 (IGFBP-3) increased in a dose-related manner, with maximum responses observed at 33-96 and 42-109 hours, respectively. IGF-1 and IGFBP-3 returned to baseline values at 168 hours following 7.5 and 15 mg of TV-1106, and 336 hours following 50 and 100 mg of TV-1106. TV-1106 appeared safe in both populations. There was no evidence of differences in pharmacokinetics, pharmacodynamics, or safety of TV-1106 between Japanese and caucasian populations. The data also demonstrate long-acting growth hormone properties of TV-1106 and support its potential for once-weekly dosing. © 2016, The Authors. Clinical Pharmacology in Drug Development Published by Wiley Periodicals, Inc. on behalf of The American College of Clinical Pharmacology.

  14. Integrating Language, Pragmatics, and Social Intervention in a Single-Subject Case Study of a Child With a Developmental Social Communication Disorder.

    Science.gov (United States)

    Adams, Catherine; Gaile, Jacqueline; Lockton, Elaine; Freed, Jenny

    2015-10-01

    This clinical focus article presents an illustration of a complex communication intervention, the Social Communication Intervention Programme (SCIP), as delivered to a child who has a social communication disorder (SCD). The SCIP intervention combined language processing and pragmatic and social understanding therapies in a program of individualized therapy activities and in close liaison with families. The study used an enhanced AB single-subject design in which an 8-year-old child with an SCD participated in 20 therapy sessions with a specialist speech-language pathologist. A procedure of matching assessment findings to intervention choices was followed to construct an individualized treatment program. Examples of intervention content and the embedded structure of SCIP are illustrated. Observational and formal measurements of receptive and expressive language, conversation, and parent-teacher ratings of social communication were completed before therapy, after therapy, and at a 6-month follow-up session. Outcomes revealed change in total and receptive language scores but not in expressive language. Conversation showed marked improvement in responsiveness, appreciation of listener knowledge, turn taking, and adaptation of discourse style. Teacher-reported outcomes included improved classroom behavior and enhanced literacy skills. Parent-reported outcomes included improved verbal interactions with family members and personal narratives. This clinical focus article demonstrates the complexity of needs in a child with an SCD and how these can be addressed in individualized intervention. Findings are discussed in relation to the essential nature of language support including pragmatic therapy for children with SCDs. Discussion of the role of formal and functional outcome measurement as well as the proximity of chosen outcomes to the intervention is included.

  15. Optimization Design of Structures Subjected to Transient Loads Using First and Second Derivatives of Dynamic Displacement and Stress

    Directory of Open Access Journals (Sweden)

    Qimao Liu

    2012-01-01

    Full Text Available This paper developed an effective optimization method, i.e., gradient-Hessian matrix-based method or second order method, of frame structures subjected to the transient loads. An algorithm of first and second derivatives of dynamic displacement and stress with respect to design variables is formulated based on the Newmark method. The inequality time-dependent constraint problem is converted into a sequence of appropriately formed time-independent unconstrained problems using the integral interior point penalty function method. The gradient and Hessian matrixes of the integral interior point penalty functions are also computed. Then the Marquardt's method is employed to solve unconstrained problems. The numerical results show that the optimal design method proposed in this paper can obtain the local optimum design of frame structures and sometimes is more efficient than the augmented Lagrange multiplier method.

  16. Italy-Japan international project-based learning for developing human resources using design of welfare equipment as a subject.

    Science.gov (United States)

    Hanafusa, A; Komeda, T; Ito, K; Zobel, P Beomonte

    2015-08-01

    Project-based learning (PBL) is effective for developing human resources of young students. The design of welfare equipment, such as wheelchairs and gait assistive devices, is taken as the subject in this study because these devices must be fit to their environment, users, and method of use; students must consider the circumstances of each country concerned. The program commenced in 2012 at L'Aquila, Italy, and the Shibaura Institute of Technology, Japan and has been continuing for three years. Students were divided into four groups and discussions were held on how to adapt the equipment to the user and environment. After discussion, they designed and simulated a model of the equipment using CAD. Finally, they presented their designs to each other. Through the program, students had fruitful discussions, exchanged ideas from different cultures, and learned from each other. Furthermore, friendships among the students were nurtured. It is believed that the objective of the program was satisfactorily accomplished.

  17. Finite Element Simulation and Assessment of Single-Degree-of-Freedom Prediction Methodology for Insulated Concrete Sandwich Panels Subjected to Blast Loads

    Science.gov (United States)

    2011-02-01

    Precast /prestressed components, along with their connections to the structure, should be designed to withstand the blast to prevent falling or...response of the component. Connections used for precast components subjected to blast are normally designed with small to zero dynamic increase...methodology considers fixed boundary condition to be more similar to continuous beams or columns . Figure 71 and Table 14 present the comparisons

  18. An Investigation of dynamic characteristics of structures subjected to dynamic load from the viewpoint of design

    International Nuclear Information System (INIS)

    Lee, Hyun Ah; Kim, Yong Il; Park, Gyung Jin; Kang, Byung Soo; Kim, Joo Sung

    2006-01-01

    All the loads in the real world are dynamic loads and structural optimization under dynamic loads is very difficult. Thus the dynamic loads are often transformed to static loads by dynamic factors, which are believed equivalent to the dynamic loads. However, due to the difference of load characteristics, there can be considerable differences between the results from static and dynamic analyses. When the natural frequency of a structure is high, the dynamic analysis result is similar to that of static analysis due to the small inertia effect on the behavior of the structure. However, if the natural frequency of the structure is low, the inertia effect should not be ignored. then, the behavior of the dynamic system is different from that of the static system. The difference of the two cases can be explained from the relationship between the homogeneous and the particular solutions of the differential equation that governs the behavior of the structure. Through various examples, the difference between the dynamic analysis and the static analysis are shown. Also dynamic response optimization results are compared with the results with static loads transformed from dynamic loads by dynamic factors, which show the necessity of the design considering dynamic loads

  19. Towards Subject-Specific Strength Training Design through Predictive Use of Musculoskeletal Models

    Directory of Open Access Journals (Sweden)

    Michael Plüss

    2018-01-01

    Full Text Available Lower extremity dysfunction is often associated with hip muscle strength deficiencies. Detailed knowledge of the muscle forces generated in the hip under specific external loading conditions enables specific structures to be trained. The aim of this study was to find the most effective movement type and loading direction to enable the training of specific parts of the hip muscles using a standing posture and a pulley system. In a novel approach to release the predictive power of musculoskeletal modelling techniques based on inverse dynamics, flexion/extension and ab-/adduction movements were virtually created. To demonstrate the effectiveness of this approach, three hip orientations and an external loading force that was systematically rotated around the body were simulated using a state-of-the art OpenSim model in order to establish ideal designs for training of the anterior and posterior parts of the M. gluteus medius (GM. The external force direction as well as the hip orientation greatly influenced the muscle forces in the different parts of the GM. No setting was found for simultaneous training of the anterior and posterior parts with a muscle force higher than 50% of the maximum. Importantly, this study has demonstrated the use of musculoskeletal models as an approach to predict muscle force variations for different strength and rehabilitation exercise variations.

  20. Pharmacokinetics After Single Ascending Dose, Food Effect, and Safety of Sacubitril/Valsartan (LCZ696), an Angiotensin Receptor and Neprilysin Inhibitor, in Healthy Japanese Subjects.

    Science.gov (United States)

    Akahori, Mizuki; Ayalasomayajula, Surya; Langenickel, Thomas; Pal, Parasar; Zhou, Wei; Sunkara, Gangadhar

    2017-06-01

    LCZ696 (sacubitril/valsartan) is a novel angiotensin receptor neprilysin inhibitor (ARNI) that has been developed for treatment of heart failure patients with reduced ejection fraction and approved in the US, Europe, and many other countries. This randomized, placebo-controlled study was conducted in healthy Japanese male subjects (N = 50) to assess the pharmacokinetics and safety of single ascending oral doses (20-600 mg) of LCZ696. Food effect was also evaluated following administration of 200 mg dose. Plasma and urine samples from 40 subjects receiving LCZ696 were collected to assess pharmacokinetics of LCZ696 analytes (sacubitril, sacubitrilat, and valsartan). Following single oral dose administration of LCZ696, sacubitril and valsartan rapidly appeared in systemic circulation with a dose-linear increase in the exposure to the LCZ696 analytes. Of the administered dose, approximately 0.85 %, 54.0 %, and 8.19 % of sacubitril, sacubitrilat, and valsartan, respectively, were recovered in urine. Food reduced AUC of sacubitril, sacubitrilat, and valsartan by 21, 8, and 40 %, respectively, and C max by 72, 27, and 51 %, respectively. Single oral doses of up to 600 mg of LCZ696 were safe and generally well tolerated in healthy Japanese male subjects.

  1. Subjective perception of cocaine reward in mice assessed by a single exposure place preference (sePP) paradigm

    DEFF Research Database (Denmark)

    Runegaard, Annika H.; Jensen, Kathrine Louise; Dencker, Ditte

    2017-01-01

    -related behavior. Comparison with existing methods In rodents, the rewarding effects of drugs have often been assessed in self-administration or place preference paradigms; both involving repeated drug exposure and weeks of training and testing. New method Our investigation describes a valid approach to assess....... The sePP protocol allows further dissection of the mechanism and influence of initial cocaine exposure on subsequent drug-related behaviors by including extinction and reinstatement. The lack of sePP in female mice may reflect a biologically relevant sex difference in the initial subjective perception...

  2. Design of a single cylinder optical access to the combustion engine Scania D12

    Energy Technology Data Exchange (ETDEWEB)

    Fuchs, Juergen

    2000-11-01

    In this work a maximum optical access to a diesel engine is developed. The combustion-process in the engine should be representative to the one in a standard engine, so the geometry of the combustion chamber is modified as little as possible. A Scania single cylinder, 2-litre engine was subjected to modifications allowing the optical access. Solutions to these problems are obtained by using the method of Product-Development, mainly based on the literature by Prof Dr.-Ing. Birkhofer at the Technical University of Darmstadt, Germany. An optical engine design of the Bowditch type was the chosen main working principle. This engine contains an extended cylinder, partly made of glass, a glass piston-crown and a mirror placed inside the extended piston. The laser sheet is led into the combustion chamber through the glass part of the cylinder, then gets reflected inside the combustion chamber and is led through the glass piston crown and via the mirror out of the engine. A redesign of the valve-train, using extended push-rods, is necessary. The demand to examine the combustion at Top-Dead-Centre (TDC) and the necessity of supporting the glass, give the reasons to do work on the cylinder head. This in return brings sealing problems, which have been solved. Another problem that occurs with that type of engine is that is has to run without oil-lubrication. Piston rings made of Rylon are used to solve this problem. A special feature of the engine that has been constructed here is that the inner surface of the glass may be cleaned without removing the cylinder head. This is obtained by a construction with a movable cylinder. In cleaning-state the cylinder is driven up and down together with the piston, while the head is supported by an outer structure. When running the engine, the cylinder is fixed to the structure. Furthermore this report contains the necessary calculations and integrity assessments on the critical parts of the construction. All calculations, except the

  3. Design of a hybrid double-sideband/single-sideband (schlieren) objective aperture suitable for electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Buijsse, Bart; Laarhoven, Frank M.H.M. van [FEI Company, PO Box 80066, 5600 KA Eindhoven (Netherlands); Schmid, Andreas K.; Cambie, Rossana; Cabrini, Stefano; Jin, Jian [Lawrence Berkeley National Laboratory, University of California, Berkeley, CA 94720 (United States); Glaeser, Robert M., E-mail: rmglaeser@lbl.gov [Lawrence Berkeley National Laboratory, University of California, Berkeley, CA 94720 (United States)

    2011-12-15

    A novel design is described for an aperture that blocks a half-plane of the electron diffraction pattern out to a desired scattering angle, and then - except for a narrow support beam - transmits all of the scattered electrons beyond that angle. Our proposed tulip-shaped design is thus a hybrid between the single-sideband (ssb) aperture, which blocks a full half-plane of the diffraction pattern, and the conventional (i.e. fully open) double-sideband (dsb) aperture. The benefits of this hybrid design include the fact that such an aperture allows one to obtain high-contrast images of weak-phase objects with the objective lens set to Scherzer defocus. We further demonstrate that such apertures can be fabricated from thin-foil materials by milling with a focused ion beam (FIB), and that such apertures are fully compatible with the requirements of imaging out to a resolution of at least 0.34 nm. As is known from earlier work with single-sideband apertures, however, the edge of such an aperture can introduce unwanted, electrostatic phase shifts due to charging. The principal requirement for using such an aperture in a routine data-collection mode is thus to discover appropriate materials, protocols for fabrication and processing and conditions of use such that the hybrid aperture remains free of charging over long periods of time. -- Highlights: Black-Right-Pointing-Pointer New objective-aperture design is proposed for imaging weak-phase objects. Black-Right-Pointing-Pointer Design produces single-sideband contrast at low spatial frequencies. Black-Right-Pointing-Pointer Design also retains Scherzer-defocus phase contrast at higher resolution. Black-Right-Pointing-Pointer Proof-of-concept results are presented for microfabricated apertures. Black-Right-Pointing-Pointer Charging of such apertures during use remains an experimental challenge.

  4. Neuropsychological Performance and Subjective Symptom Reporting in Military Service Members With a History of Multiple Concussions: Comparison With a Single Concussion, Posttraumatic Stress Disorder, and Orthopedic Trauma.

    Science.gov (United States)

    Cooper, Douglas B; Curtiss, Glenn; Armistead-Jehle, Patrick; Belanger, Heather G; Tate, David F; Reid, Matthew; Bowles, Amy O; Velez, Carmen S; Kennedy, Jan E; Vanderploeg, Rodney D

    To examine differences in objective neurocognitive performance and subjective cognitive symptoms in individuals with a history of a single concussion, multiple concussions, orthopedic injuries, and posttraumatic stress disorder (PTSD). Participants included 116 military service members who sustained a mild traumatic brain injury (mTBI) during combat deployment. Subjects were subdivided into groups based on concussion frequency: a single concussion (n = 42), 2 concussions (n = 21), and 3 or more concussions (n = 53). Eighty-one subjects sustained an orthopedic injury (n = 60) during deployment or were diagnosed with PTSD (n = 21), but had no history of mTBI. Subjects completed a battery of neuropsychological tests and self-report measures of postconcussive symptoms, PTSD symptoms, and psychopathology. No differences were found among the concussion groups on a composite neuropsychological measure. The PTSD group had the highest number of symptom complaints, with the 2-concussion and 3-plus-concussion groups being most similar to the PTSD group. The concussion groups showed a nonsignificant pattern of increasing distress with increasing number of concussions. The current findings are consistent with meta-analytic results showing no differential effect on neuropsychological functioning due to multiple concussions. Results also support the burden of adversity hypothesis suggesting increasing symptom levels with increasing psychological or physically traumatic exposures.

  5. Research design considerations for single-dose analgesic clinical trials in acute pain

    DEFF Research Database (Denmark)

    Cooper, Stephen A; Desjardins, Paul J; Turk, Dennis C

    2016-01-01

    This article summarizes the results of a meeting convened by the Initiative on Methods, Measurement, and Pain Assessment in Clinical Trials (IMMPACT) on key considerations and best practices governing the design of acute pain clinical trials. We discuss the role of early phase clinical trials......, including pharmacokinetic-pharmacodynamic (PK-PD) trials, and the value of including both placebo and active standards of comparison in acute pain trials. This article focuses on single-dose and short-duration trials with emphasis on the perioperative and study design factors that influence assay...... sensitivity. Recommendations are presented on assessment measures, study designs, and operational factors. Although most of the methodological advances have come from studies of postoperative pain after dental impaction, bunionectomy, and other surgeries, the design considerations discussed are applicable...

  6. Design of nanostrip magnonic crystal waveguides with a single magnonic band gap

    International Nuclear Information System (INIS)

    Wang, Qi; Zhong, Zhiyong; Jin, Lichuan; Tang, Xiaoli; Bai, Feiming; Zhang, Huaiwu; Beach, Geoffrey S.D.

    2013-01-01

    A novel planar structure of magnonic-crystal waveguide (MCW) with periodic rectangular-shaped holes embedded in a magnetic nanostrip film was designed. The effects of the distance between rectangular-shaped holes in the width direction of MCW on magnonic band structures were studied by micromagnetic simulations. The results show that a MCW with a single magnonic band gap can be obtained by adjusting the distance to meet the condition of Bragg reflection of spin waves in the width direction of MCW. Moreover, the center frequency and width of magnonic gap can be regulated by changing the period and length of rectangular-shaped holes. - Highlights: • Design a novel planar structure of magnonic-crystal waveguide. • The physical origin of a single magnonic band gap. • Study of the center frequency and width of magnonic gap

  7. Design study of technology requirements for high performance single-propeller-driven business airplanes

    Science.gov (United States)

    Kohlman, D. L.; Hammer, J.

    1985-01-01

    Developments in aerodyamic, structural and propulsion technologies which influence the potential for significant improvements in performance and fuel efficiency of general aviation business airplanes are discussed. The advancements include such technolgies as natural laminar flow, composite materials, and advanced intermittent combustion engines. The design goal for this parameter design study is a range of 1300 nm at 300 knots true airspeed with a payload of 1200lbs at 35,000 ft cruise altitude. The individual and synergistic effects of various advanced technologies on the optimization of this class of high performance, single engine, propeller driven business airplanes are identified.

  8. Single Phase Current-Source Active Rectifier for Traction: Control System Design and Practical Problems

    Directory of Open Access Journals (Sweden)

    Jan Michalik

    2006-01-01

    Full Text Available This research has been motivated by industrial demand for single phase current-source active rectifier dedicated for reconstruction of older types of dc machine locomotives. This paper presents converters control structure design and simulations. The proposed converter control is based on the mathematical model and due to possible interaction with railway signaling and required low switching frequency employs synchronous PWM. The simulation results are verified by experimental tests performed on designed laboratory prototype of power of 7kVA

  9. Design of a multi beam klystron cavity from its single beam parameters

    Energy Technology Data Exchange (ETDEWEB)

    Kant, Deepender, E-mail: dkc@ceeri.ernet.in; Joshi, L. M. [CSIR-Central Electronics Engineering Research Institute, Pilani (India); Janyani, Vijay [Department of ECE, MNIT, Jaipur (India)

    2016-03-09

    The klystron is a well-known microwave amplifier which uses kinetic energy of an electron beam for amplification of the RF signal. There are some limitations of conventional single beam klystron such as high operating voltage, low efficiency and bulky size at higher power levels, which are very effectively handled in Multi Beam Klystron (MBK) that uses multiple low purveyance electron beams for RF interaction. Each beam propagates along its individual transit path through a resonant cavity structure. Multi-Beam klystron cavity design is a critical task due to asymmetric cavity structure and can be simulated by 3D code only. The present paper shall discuss the design of multi beam RF cavities for klystrons operating at 2856 MHz (S-band) and 5 GHz (C-band) respectively. The design approach uses some scaling laws for finding the electron beam parameters of the multi beam device from their single beam counter parts. The scaled beam parameters are then used for finding the design parameters of the multi beam cavities. Design of the desired multi beam cavity can be optimized through iterative simulations in CST Microwave Studio.

  10. Design of a multi beam klystron cavity from its single beam parameters

    International Nuclear Information System (INIS)

    Kant, Deepender; Joshi, L. M.; Janyani, Vijay

    2016-01-01

    The klystron is a well-known microwave amplifier which uses kinetic energy of an electron beam for amplification of the RF signal. There are some limitations of conventional single beam klystron such as high operating voltage, low efficiency and bulky size at higher power levels, which are very effectively handled in Multi Beam Klystron (MBK) that uses multiple low purveyance electron beams for RF interaction. Each beam propagates along its individual transit path through a resonant cavity structure. Multi-Beam klystron cavity design is a critical task due to asymmetric cavity structure and can be simulated by 3D code only. The present paper shall discuss the design of multi beam RF cavities for klystrons operating at 2856 MHz (S-band) and 5 GHz (C-band) respectively. The design approach uses some scaling laws for finding the electron beam parameters of the multi beam device from their single beam counter parts. The scaled beam parameters are then used for finding the design parameters of the multi beam cavities. Design of the desired multi beam cavity can be optimized through iterative simulations in CST Microwave Studio.

  11. Methodology for the structural design of single spoke accelerating cavities at Fermilab

    International Nuclear Information System (INIS)

    Passarelli, Donato; Merio, Margherita; Ristori, Leonardo

    2016-01-01

    Fermilab is planning to upgrade its accelerator complex to deliver a more powerful and intense proton-beam for neutrino experiments. In the framework of the so-called Proton Improvement Plan-II (PIP-II), we are designing and developing a cryomodule containing superconducting accelerating cavities, the Single Spoke Resonators of type 1 (SSR1). In this paper, we present the sequence of analysis and calculations performed for the structural de- sign of these cavities, using the rules of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (BPVC). The lack of an accepted procedure for addressing the design, fabrication, and inspection of such unique pressure vessels makes the task demanding and challenging every time. Several factors such as exotic materials, unqualified brazing procedures, limited nondestructive examination, and the general R&D nature of these early generations of cavity design, conspire to make it impractical to obtain full compliance with all ASME BPVC requirements. However, the presented approach allowed us to validate the design of these new generation of single spoke cavities with values of maximum allowable working pressure that exceed the safety requirements. This set of rules could be used as a starting point for the structural design and development of similar objects.

  12. Structural analysis of the CAREM-25 nuclear power plant subjected to the design basis accident and seismic loads

    International Nuclear Information System (INIS)

    Ambrosini, Daniel; Codina, Ramón H.; Curadelli, Oscar; Martínez, Carlos A.

    2017-01-01

    Highlights: • Structural analysis of CAREM-25 NPP is presented. • Full 3D numerical model was developed. • Transient thermal and static structural analyses were performed. • Modeling guidelines for numerical structural analysis of NPP are recommended. • Envelope condition of DBA dominates the structural behavior. - Abstract: In this paper, a numerical study about the structural response of the Argentine nuclear power plant CAREM-25 subjected to the design basis accident (DBA) and seismic loads is presented. Taking into account the hardware capabilities available, a full 3D finite element model was adopted. A significant part of the building was modeled using more than 2 M solid elements. In order to take into account the foundation flexibility, linear springs were used. The springs and the model were calibrated against a greater model used to study the soil-structure interaction. The structure was subjected to the DBA and seismic loads as combinations defined by ASME international code. First, a transient thermal analysis was performed with the conditions defined by DBA and evaluating the time history of the temperature of the model, each 1 h until 36 h. The final results of this stage were considered as initial conditions of a static structural analysis including the pressure defined by DBA. Finally, an equivalent static analysis was performed to analyze the seismic response considering the design basis spectra for the site. The different loads were combined and the abnormal/extreme environmental combination was the most unfavorable for the structure, defining the design.

  13. Self-Similar Nanocavity Design with Ultrasmall Mode Volume for Single-Photon Nonlinearities

    DEFF Research Database (Denmark)

    Choi, Hyeongrak; Heuck, Mikkel; Englund, Dirk R.

    2017-01-01

    We propose a photonic crystal nanocavity design with self-similar electromagnetic boundary conditions, achieving ultrasmall mode volume (V-eff). The electric energy density of a cavity mode can be maximized in the air or dielectric region, depending on the choice of boundary conditions. We illust...... at the single-photon level. These features open new directions in cavity quantum electrodynamics, spectroscopy, and quantum nonlinear optics....

  14. Solar energy heating system design package for a single-family residence at New Castle, Pennsylvania

    Energy Technology Data Exchange (ETDEWEB)

    1977-08-01

    The design of a solar heating and hot water system for the New Castle Redevelopment Authority's single-family dwelling located at New Castle, Pennsylvania is described. Documentation submitted by the contractor for Government review of plans, specifications, cost trade studies and verification status for approval to commit the system to fabrication is presented. Also included are system integration drawings, major subsystems drawings, and architect's specifications and plans.

  15. Esthetic Evaluation of Anterior Single-Tooth Implants with Different Abutment Designs-Patients' Satisfaction Compared to Dentists' Observations.

    Science.gov (United States)

    Patil, Ratnadeep; Gresnigt, Marco M M; Mahesh, Kavita; Dilbaghi, Anjali; Cune, Marco S

    2017-07-01

    To correlate patients' satisfaction and dentists' observations regarding two abutment designs used for single crowns in the esthetic zone: a divergent one (control) and a curved one (experimental), with special emphasis on muco-gingival esthetics. Twenty-six patients with nonadjacent missing teeth in the esthetic zone were enrolled in a randomized clinical trial (within-subject comparison). Two implants placed in each were restored using abutments of different geometry. Patients' appreciation was assessed on a visual analog scale (VAS) by recording answers to three questions, and dentists' appreciation was determined by means of the Pink Esthetic Score (PES) at T0 (crown cementation, baseline) and at T12 (1 year post-cementation). ANOVA with post hoc analysis was used to identify differences between groups and at different moments in time. Pearson correlations were calculated between all variables, both at T0 and at T12. No statistically significant differences were found at any time between the control and experimental abutment design, either for the PES or for the VAS score. PES slightly improved after 1 year, as did the VAS rating related to functioning with the implant-crown compared to the natural teeth. All PES and VAS scores demonstrated highly significant correlation. Both patient satisfaction and professional appreciation of muco-gingival conditions after single implant treatment in the esthetic zone were high; however, the curved, experimental abutment design performed no better than the conventional, divergent type. Curved abutment design does not significantly impact crown or gingival esthetics as assessed by PES and VAS scored by dentists and patients, respectively. © 2016 by the American College of Prosthodontists.

  16. QuantifyMe: An Open-Source Automated Single-Case Experimental Design Platform †

    Science.gov (United States)

    Sano, Akane; Ferguson, Craig; Mohan, Akshay; Picard, Rosalind W.

    2018-01-01

    Smartphones and wearable sensors have enabled unprecedented data collection, with many products now providing feedback to users about recommended step counts or sleep durations. However, these recommendations do not provide personalized insights that have been shown to be best suited for a specific individual. A scientific way to find individualized recommendations and causal links is to conduct experiments using single-case experimental design; however, properly designed single-case experiments are not easy to conduct on oneself. We designed, developed, and evaluated a novel platform, QuantifyMe, for novice self-experimenters to conduct proper-methodology single-case self-experiments in an automated and scientific manner using their smartphones. We provide software for the platform that we used (available for free on GitHub), which provides the methodological elements to run many kinds of customized studies. In this work, we evaluate its use with four different kinds of personalized investigations, examining how variables such as sleep duration and regularity, activity, and leisure time affect personal happiness, stress, productivity, and sleep efficiency. We conducted a six-week pilot study (N = 13) to evaluate QuantifyMe. We describe the lessons learned developing the platform and recommendations for its improvement, as well as its potential for enabling personalized insights to be scientifically evaluated in many individuals, reducing the high administrative cost for advancing human health and wellbeing. PMID:29621133

  17. QuantifyMe: An Open-Source Automated Single-Case Experimental Design Platform

    Directory of Open Access Journals (Sweden)

    Sara Taylor

    2018-04-01

    Full Text Available Smartphones and wearable sensors have enabled unprecedented data collection, with many products now providing feedback to users about recommended step counts or sleep durations. However, these recommendations do not provide personalized insights that have been shown to be best suited for a specific individual. A scientific way to find individualized recommendations and causal links is to conduct experiments using single-case experimental design; however, properly designed single-case experiments are not easy to conduct on oneself. We designed, developed, and evaluated a novel platform, QuantifyMe, for novice self-experimenters to conduct proper-methodology single-case self-experiments in an automated and scientific manner using their smartphones. We provide software for the platform that we used (available for free on GitHub, which provides the methodological elements to run many kinds of customized studies. In this work, we evaluate its use with four different kinds of personalized investigations, examining how variables such as sleep duration and regularity, activity, and leisure time affect personal happiness, stress, productivity, and sleep efficiency. We conducted a six-week pilot study (N = 13 to evaluate QuantifyMe. We describe the lessons learned developing the platform and recommendations for its improvement, as well as its potential for enabling personalized insights to be scientifically evaluated in many individuals, reducing the high administrative cost for advancing human health and wellbeing.

  18. QuantifyMe: An Open-Source Automated Single-Case Experimental Design Platform.

    Science.gov (United States)

    Taylor, Sara; Sano, Akane; Ferguson, Craig; Mohan, Akshay; Picard, Rosalind W

    2018-04-05

    Smartphones and wearable sensors have enabled unprecedented data collection, with many products now providing feedback to users about recommended step counts or sleep durations. However, these recommendations do not provide personalized insights that have been shown to be best suited for a specific individual. A scientific way to find individualized recommendations and causal links is to conduct experiments using single-case experimental design; however, properly designed single-case experiments are not easy to conduct on oneself. We designed, developed, and evaluated a novel platform, QuantifyMe, for novice self-experimenters to conduct proper-methodology single-case self-experiments in an automated and scientific manner using their smartphones. We provide software for the platform that we used (available for free on GitHub), which provides the methodological elements to run many kinds of customized studies. In this work, we evaluate its use with four different kinds of personalized investigations, examining how variables such as sleep duration and regularity, activity, and leisure time affect personal happiness, stress, productivity, and sleep efficiency. We conducted a six-week pilot study ( N = 13) to evaluate QuantifyMe. We describe the lessons learned developing the platform and recommendations for its improvement, as well as its potential for enabling personalized insights to be scientifically evaluated in many individuals, reducing the high administrative cost for advancing human health and wellbeing.

  19. Stress in closed thin-walled tubes of single box subjected by shear forces and application to airfoils

    Directory of Open Access Journals (Sweden)

    Zebbiche Toufik

    2014-09-01

    Full Text Available The presented work is to develop a numerical computation program to determine the distribution of the shear stress to shear in closed tubes with asymmetric single thin wall section with a constant thickness and applications to airfoils and therefore determining the position and value of the maximum stress. In the literature, there are exact analytical solutions only for some sections of simple geometries such as circular section. Hence our interest is focused on the search of approximate numerical solutions for more complex sections used in aeronautics. In the second stage the position of the shear center is determined so that the section does not undergo torsion. The analytic function of the boundary of the airfoil is obtained by using the cubic spline interpolation since it is given in the form of tabulated points.

  20. Software for generation and analysis of photoelastic fringes in plates with a single hole subjected to in-plane loads

    International Nuclear Information System (INIS)

    Soares, W.A.; Andrade, A.H.P.

    1995-01-01

    A software package for generating and analyzing photoelastic images on infinite rectangular plates, subjected to in-plane loads, is being presented. It allows the user to generate photoelastic images as produced in a polariscope fed by monochromatic light. Both circular and plane polariscopes in conditions of dark or light field can be selected. Tools for obtaining light intensity distributions along horizontal and vertical lines and for extracting darkest regions of photoelastic fringes are also available. The extraction of such regions can be done by digital image processing (DIP). This process produces thin lines, from which main stresses and intensity factor used in the Fracture Mechanics can be obtained. The software was developed for running on DOS environment in Super VGA mode. The synthetic photoelastic images are generated in 64 gray levels. This software is a useful tool for teaching the fundamentals of photoelasticity and will help the researchers in the development of photoelastic experiments. (author). 6 fefs., 7 figs

  1. Flexible Design and Operation of Multi-Stage Flash (MSF Desalination Process Subject to Variable Fouling and Variable Freshwater Demand

    Directory of Open Access Journals (Sweden)

    Said Alforjani Said

    2013-10-01

    Full Text Available This work describes how the design and operation parameters of the Multi-Stage Flash (MSF desalination process are optimised when the process is subject to variation in seawater temperature, fouling and freshwater demand throughout the day. A simple polynomial based dynamic seawater temperature and variable freshwater demand correlations are developed based on actual data which are incorporated in the MSF mathematical model using gPROMS models builder 3.0.3. In addition, a fouling model based on stage temperature is considered. The fouling and the effect of noncondensable gases are incorporated into the calculation of overall heat transfer co-efficient for condensers. Finally, an optimisation problem is developed where the total daily operating cost of the MSF process is minimised by optimising the design (no of stages and the operating (seawater rejected flowrate and brine recycle flowrate parameters.

  2. Design and experimental validation of Unilateral Linear Halbach magnet arrays for single-sided magnetic resonance.

    Science.gov (United States)

    Bashyam, Ashvin; Li, Matthew; Cima, Michael J

    2018-07-01

    Single-sided NMR has the potential for broad utility and has found applications in healthcare, materials analysis, food quality assurance, and the oil and gas industry. These sensors require a remote, strong, uniform magnetic field to perform high sensitivity measurements. We demonstrate a new permanent magnet geometry, the Unilateral Linear Halbach, that combines design principles from "sweet-spot" and linear Halbach magnets to achieve this goal through more efficient use of magnetic flux. We perform sensitivity analysis using numerical simulations to produce a framework for Unilateral Linear Halbach design and assess tradeoffs between design parameters. Additionally, the use of hundreds of small, discrete magnets within the assembly allows for a tunable design, improved robustness to variability in magnetization strength, and increased safety during construction. Experimental validation using a prototype magnet shows close agreement with the simulated magnetic field. The Unilateral Linear Halbach magnet increases the sensitivity, portability, and versatility of single-sided NMR. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. Using machine learning to identify structural breaks in single-group interrupted time series designs.

    Science.gov (United States)

    Linden, Ariel; Yarnold, Paul R

    2016-12-01

    Single-group interrupted time series analysis (ITSA) is a popular evaluation methodology in which a single unit of observation is being studied, the outcome variable is serially ordered as a time series and the intervention is expected to 'interrupt' the level and/or trend of the time series, subsequent to its introduction. Given that the internal validity of the design rests on the premise that the interruption in the time series is associated with the introduction of the treatment, treatment effects may seem less plausible if a parallel trend already exists in the time series prior to the actual intervention. Thus, sensitivity analyses should focus on detecting structural breaks in the time series before the intervention. In this paper, we introduce a machine-learning algorithm called optimal discriminant analysis (ODA) as an approach to determine if structural breaks can be identified in years prior to the initiation of the intervention, using data from California's 1988 voter-initiated Proposition 99 to reduce smoking rates. The ODA analysis indicates that numerous structural breaks occurred prior to the actual initiation of Proposition 99 in 1989, including perfect structural breaks in 1983 and 1985, thereby casting doubt on the validity of treatment effects estimated for the actual intervention when using a single-group ITSA design. Given the widespread use of ITSA for evaluating observational data and the increasing use of machine-learning techniques in traditional research, we recommend that structural break sensitivity analysis is routinely incorporated in all research using the single-group ITSA design. © 2016 John Wiley & Sons, Ltd.

  4. Single Low Dose Primaquine (0.25 mg/kg Does Not Cause Clinically Significant Haemolysis in G6PD Deficient Subjects.

    Directory of Open Access Journals (Sweden)

    Germana Bancone

    Full Text Available Primaquine is the only drug consistently effective against mature gametocytes of Plasmodium falciparum. The transmission blocking dose of primaquine previously recommended was 0.75 mg/kg (adult dose 45 mg but its deployment was limited because of concerns over haemolytic effects in patients with glucose-6-phosphate dehydrogenase (G6PD deficiency. G6PD deficiency is an inherited X-linked enzymatic defect that affects an estimated 400 million people around the world with high frequencies (15-20% in populations living in malarious areas. To reduce transmission in low transmission settings and facilitate elimination of P. falciparum, the World Health Organization now recommends adding a single dose of 0.25 mg/kg (adult dose 15 mg to Artemisinin-based Combination Therapies (ACTs without G6PD testing. Direct evidence of the safety of this low dose is lacking. Adverse events and haemoglobin variations after this treatment were assessed in both G6PD normal and deficient subjects in the context of targeted malaria elimination in a malaria endemic area on the North-Western Myanmar-Thailand border where prevalence of G6PD deficiency (Mahidol variant approximates 15%.The tolerability and safety of primaquine (single dose 0.25 mg base/kg combined with dihydroartemisinin-piperaquine (DHA-PPQ given three times at monthly intervals was assessed in 819 subjects. Haemoglobin concentrations were estimated over the six months preceding the ACT + primaquine rounds of mass drug administration. G6PD deficiency was assessed with a phenotypic test and genotyping was performed in male subjects with deficient phenotypes and in all females. Fractional haemoglobin changes in relation to G6PD phenotype and genotype and primaquine round were assessed using linear mixed-effects models. No adverse events related to primaquine were reported during the trial. Mean fractional haemoglobin changes after each primaquine treatment in G6PD deficient subjects (-5.0%, -4.2% and -4

  5. Design optimization of the distributed modal filtering rod fiber for increasing single mode bandwidth

    DEFF Research Database (Denmark)

    Jørgensen, Mette Marie; Petersen, Sidsel Rübner; Laurila, Marko

    2012-01-01

    . Large preform tolerances are compensated during the fiber draw resulting in ultra low NA fibers with very large cores. In this paper, design optimization of the SM bandwidth of the DMF rod fiber is presented. Analysis of band gap properties results in a fourfold increase of the SM bandwidth compared...... LMA fiber amplifiers having high pump absorption through a pump cladding that is decoupled from the outer fiber. However, achieving ultra low NA for single-mode (SM) guidance is challenging, and thus different design strategies must be applied to filter out higher order modes (HOMs). The novel...... distributed modal filtering (DMF) design presented here enables SM guidance, and previous results have shown a SM mode field diameter of 60 μm operating in a 20 nm SM bandwidth. The DMF rod fiber has high index ring-shaped inclusions acting as resonators enabling SM guidance through modal filtering of HOMs...

  6. Comparisons between designs for single-sided linear electric motors: Homopolar synchronous and induction

    Science.gov (United States)

    Nondahl, T. A.; Richter, E.

    1980-09-01

    A design study of two types of single sided (with a passive rail) linear electric machine designs, namely homopolar linear synchronous machines (LSM's) and linear induction machines (LIM's), is described. It is assumed the machines provide tractive effort for several types of light rail vehicles and locomotives. These vehicles are wheel supported and require tractive powers ranging from 200 kW to 3735 kW and top speeds ranging from 112 km/hr to 400 km/hr. All designs are made according to specified magnetic and thermal criteria. The LSM advantages are a higher power factor, much greater restoring forces for track misalignments, and less track heating. The LIM advantages are no need to synchronize the excitation frequency precisely to vehicle speed, simpler machine construction, and a more easily anchored track structure. The relative weights of the two machine types vary with excitation frequency and speed; low frequencies and low speeds favor the LSM.

  7. Conceptual Design of a Single-Aisle Turboelectric Commercial Transport With Fuselage Boundary Layer Ingestion

    Science.gov (United States)

    Welstead, Jason R.; Felder, James L.

    2016-01-01

    A single-aisle commercial transport concept with a turboelectric propulsion system architecture was developed assuming entry into service in 2035 and compared to a similar technology conventional configuration. The turboelectric architecture consisted of two underwing turbofans with generators extracting power from the fan shaft and sending it to a rear fuselage, axisymmetric, boundary layer ingesting fan. Results indicate that the turbo- electric concept has an economic mission fuel burn reduction of 7%, and a design mission fuel burn reduction of 12% compared to the conventional configuration. An exploration of the design space was performed to better understand how the turboelectric architecture changes the design space, and system sensitivities were run to determine the sensitivity of thrust specific fuel consumption at top of climb and propulsion system weight to the motor power, fan pressure ratio, and electrical transmission efficiency of the aft boundary layer ingesting fan.

  8. Masked Visual Analysis: Minimizing Type I Error in Visually Guided Single-Case Design for Communication Disorders

    Science.gov (United States)

    Byun, Tara McAllister; Hitchcock, Elaine R.; Ferron, John

    2017-01-01

    Purpose: Single-case experimental designs are widely used to study interventions for communication disorders. Traditionally, single-case experiments follow a response-guided approach, where design decisions during the study are based on participants' observed patterns of behavior. However, this approach has been criticized for its high rate of…

  9. Pharmacokinetics and Safety of DW1029M, a Botanical Drug for the Treatment of Diabetic Nephropathy, Following Single Doses in Healthy Subjects.

    Science.gov (United States)

    Kim, Yunjeong; Jeon, Ji-Young; Kim, Eun-Young; Lim, Cheol-Hee; Jang, Hwan Bong; Kim, Min-Gul

    2017-09-01

    DW1029M is a botanical extract of Morus albalinne root bark and Puerariae radix that is used for the treatment of diabetic nephropathy. This study evaluated the safety and pharmacokinetics of DW1029M following its administration in healthy Korean subjects. We conducted a randomized, open-label, single-dose, crossover phase 1 clinical study. During each period, subjects received 300, 600, or 1200 mg oral doses of DW1029M. Plasma concentrations of puerarin, daidzin, and daidzein were analyzed using a liquid chromatography-tandem mass spectrometry. Six healthy male subjects completed the study. The maximum concentration of the drug in the plasma (C max ) and area under the plasma drug concentration-time curve to the last measurable concentration (AUC last ) for puerarin, daidzin, and daidzein were assessed after oral administration of DW1029M. No serious adverse events or clinically or statistically significant adverse events associated with any of the drug levels were observed. The results of the measurement of vital signs, electrocardiogram, laboratory tests, and physical examinations indicated that no clinically significant changes occurred during this study. The DW1029M tablet was safe and well tolerated over a single dose range of 300-1200 mg. This pharmacokinetic study of a botanical drug may aid in the development of DW1029M. © 2017, The American College of Clinical Pharmacology.

  10. Vertical dynamics of a single-span beam subjected to moving mass-suspended payload system with variable speeds

    Science.gov (United States)

    He, Wei

    2018-03-01

    This paper presents the vertical dynamics of a simply supported Euler-Bernoulli beam subjected to a moving mass-suspended payload system of variable velocities. A planar theoretical model of the moving mass-suspended payload system of variable speeds is developed based on several assumptions: the rope is massless and rigid, and its length keeps constant; the stiffness of the gantry beam is much greater than the supporting beam, and the gantry beam can be treated as a mass particle traveling along the supporting beam; the supporting beam is assumed as a simply supported Bernoulli-Euler beam. The model can be degenerated to consider two classical cases-the moving mass case and the moving payload case. The proposed model is verified using both numerical and experimental methods. To further investigate the effect of possible influential factors, numerical examples are conducted covering a range of parameters, such as variable speeds (acceleration or deceleration), mass ratios of the payload to the total moving load, and the pendulum lengths. The effect of beam flexibility on swing response of the payload is also investigated. It is shown that the effect of a variable speed is significant for the deflections of the beam. The accelerating movement tends to induce larger beam deflections, while the decelerating movement smaller ones. For accelerating or decelerating movements, the moving mass model may underestimate the deflections of the beam compared with the presented model; while for uniform motion, both the moving mass model and the moving mass-payload model lead to same beam responses. Furthermore, it is observed that the swing response of the payload is not sensitive to the stiffness of the beam for operational cases of a moving crane, thus a simple moving payload model can be employed in the swing control of the payload.

  11. Design and optimization for the occupant restraint system of vehicle based on a single freedom model

    Science.gov (United States)

    Zhang, Junyuan; Ma, Yue; Chen, Chao; Zhang, Yan

    2013-05-01

    Throughout the vehicle crash event, the interactions between vehicle, occupant, restraint system (VOR) are complicated and highly non-linear. CAE and physical tests are the most widely used in vehicle passive safety development, but they can only be done with the detailed 3D model or physical samples. Often some design errors and imperfections are difficult to correct at that time, and a large amount of time will be needed. A restraint system concept design approach which based on single-degree-of-freedom occupant-vehicle model (SDOF) is proposed in this paper. The interactions between the restraint system parameters and the occupant responses in a crash are studied from the view of mechanics and energy. The discrete input and the iterative algorithm method are applied to the SDOF model to get the occupant responses quickly for arbitrary excitations (impact pulse) by MATLAB. By studying the relationships between the ridedown efficiency, the restraint stiffness, and the occupant response, the design principle of the restraint stiffness aiming to reduce occupant injury level during conceptual design is represented. Higher ridedown efficiency means more occupant energy absorbed by the vehicle, but the research result shows that higher ridedown efficiency does not mean lower occupant injury level. A proper restraint system design principle depends on two aspects. On one hand, the restraint system should lead to as high ridedown efficiency as possible, and at the same time, the restraint system should maximize use of the survival space to reduce the occupant deceleration level. As an example, an optimization of a passenger vehicle restraint system is designed by the concept design method above, and the final results are validated by MADYMO, which is the most widely used software in restraint system design, and the sled test. Consequently, a guideline and method for the occupant restraint system concept design is established in this paper.

  12. A new design approach for control circuits of pipelined single-flux-quantum microprocessors

    International Nuclear Information System (INIS)

    Yamanashi, Y; Akimoto, A; Yoshikawa, N; Tanaka, M; Kawamoto, T; Kamiya, Y; Fujimaki, A; Terai, H; Yorozu, S

    2006-01-01

    A novel method of design for controllers of pipelined microprocessors using single-flux-quantum (SFQ) logic has been proposed. The proposed design approach is based on one hot encoding and is very suitable for designing a finite state machine using SFQ logic circuits, where each internal state of the microprocessor is represented by a flip-flop. In this approach, decoding of the internal state can be performed instantaneously, in contrast to the case in the conventional method using a binary state register. Moreover, pipelining is effectively implemented without increasing the circuit size because no pipeline registers are required in the one hot encoding. By using this method, we have designed a controller for our new SFQ microprocessors, which employs pipelining. The number of Josephson junctions of the newly designed controller is 1067, while the previous version without pipelining contains 1721 Josephson junctions. These results indicate that the proposed design approach is very effective for pipelined SFQ microprocessors. We have implemented a new controller using the NEC 2.5 kA cm -2 Nb standard process and confirmed its correct operation experimentally

  13. Design of Single Stage Axial Turbine with Constant Nozzle Angle Blading for Small Turbojet

    Science.gov (United States)

    Putra Adnan, F.; Hartono, Firman

    2018-04-01

    In this paper, an aerodynamic design of a single stage gas generator axial turbine for small turbojet engine is explained. As per design requirement, the turbine should be able to deliver power output of 155 kW at 0.8139 kg/s gas mass flow, inlet total temperature of 1200 K and inlet total pressure of 335330 Pa. The design phase consist of several steps, i.e.: determination of velocity triangles in 2D plane, 2D blading design and 3D flow analysis at design point using Computational Fluid Dynamics method. In the determination of velocity triangles, two conditions are applied: zero inlet swirl (i.e. the gas flow enter the turbine at axial direction) and constant nozzle angle design (i.e. the inlet and outlet angle of the nozzle blade are constant from root to tip). The 2D approach in cascade plane is used to specify airfoil type at root, mean and tip of the blade based on inlet and outlet flow conditions. The 3D approach is done by simulating the turbine in full configuration to evaluate the overall performance of the turbine. The observed parameters including axial gap, stagger angle, and tip clearance affect its output power. Based on analysis results, axial gap and stagger angle are positively correlated with output power up to a certain point at which the power decreases. Tip clearance, however, gives inversely correlation with output power.

  14. Refined Exploration of Turbofan Design Options for an Advanced Single-Aisle Transport

    Science.gov (United States)

    Guynn, Mark D.; Berton, Jeffrey J.; Fisher, Kenneth L.; Haller, William J.; Tong, Michael T.; Thurman, Douglas R.

    2011-01-01

    A comprehensive exploration of the turbofan engine design space for an advanced technology single-aisle transport (737/A320 class aircraft) was conducted previously by the authors and is documented in a prior report. Through the course of that study and in a subsequent evaluation of the approach and results, a number of enhancements to the engine design ground rules and assumptions were identified. A follow-on effort was initiated to investigate the impacts of these changes on the original study results. The fundamental conclusions of the prior study were found to still be valid with the revised engine designs. The most significant impact of the design changes was a reduction in the aircraft weight and block fuel penalties incurred with low fan pressure ratio, ultra-high bypass ratio designs. This enables lower noise levels to be pursued (through lower fan pressure ratio) with minor negative impacts on aircraft weight and fuel efficiency. Regardless of the engine design selected, the results of this study indicate the potential for the advanced aircraft to realize substantial improvements in fuel efficiency, emissions, and noise compared to the current vehicles in this size class.

  15. Single-earthquake design for piping systems in advanced light water reactors

    International Nuclear Information System (INIS)

    Terao, D.

    1993-01-01

    Appendix A to Part 100 of Title 10 of the Code of Federal Regulations (10 CFR Part 100) requires, in part, that all structures, systems, and components of the nuclear power plant necessary for continued operation without undue risk to the health and safety of the public shall be designed to remain functional and within applicable stress and deformation limits when subject to an operating basis earthquake (OBE). The US Nuclear Regulatory Commission (NRC) is proposing changes to Appendix A to Part 100 to redefine the OBE at a level such that its purpose can be satisfied without the need to perform explicit response analyses. Consequently, only the safe-shutdown earthquake (SSE) would be required for the seismic design of safety-related structures, systems and components. The purpose of this paper is to discuss the proposed changes to existing seismic design criteria that the NRC staff has found acceptable for implementing the proposed rule change in the design of safety-related piping systems in the advanced light water reactor (ALWR) lead plant. These criteria apply only to the ALWR lead plant design and are not intended to replace the seismic design criteria approved by the Commission in the licensing bases of currently operating facilities. Although the guidelines described herein have been proposed for use as a pilot program for implementing the proposed rule change specifically for the ALWR lead plant, the NRC staff expects that these guidelines will also be applied to other ALWRs

  16. Analysis and meta-analysis of single-case designs with a standardized mean difference statistic: a primer and applications.

    Science.gov (United States)

    Shadish, William R; Hedges, Larry V; Pustejovsky, James E

    2014-04-01

    This article presents a d-statistic for single-case designs that is in the same metric as the d-statistic used in between-subjects designs such as randomized experiments and offers some reasons why such a statistic would be useful in SCD research. The d has a formal statistical development, is accompanied by appropriate power analyses, and can be estimated using user-friendly SPSS macros. We discuss both advantages and disadvantages of d compared to other approaches such as previous d-statistics, overlap statistics, and multilevel modeling. It requires at least three cases for computation and assumes normally distributed outcomes and stationarity, assumptions that are discussed in some detail. We also show how to test these assumptions. The core of the article then demonstrates in depth how to compute d for one study, including estimation of the autocorrelation and the ratio of between case variance to total variance (between case plus within case variance), how to compute power using a macro, and how to use the d to conduct a meta-analysis of studies using single-case designs in the free program R, including syntax in an appendix. This syntax includes how to read data, compute fixed and random effect average effect sizes, prepare a forest plot and a cumulative meta-analysis, estimate various influence statistics to identify studies contributing to heterogeneity and effect size, and do various kinds of publication bias analyses. This d may prove useful for both the analysis and meta-analysis of data from SCDs. Copyright © 2013 Society for the Study of School Psychology. Published by Elsevier Ltd. All rights reserved.

  17. A design of calibration single star simulator with adjustable magnitude and optical spectrum output system

    Science.gov (United States)

    Hu, Guansheng; Zhang, Tao; Zhang, Xuan; Shi, Gentai; Bai, Haojie

    2018-03-01

    In order to achieve multi-color temperature and multi-magnitude output, magnitude and temperature can real-time adjust, a new type of calibration single star simulator was designed with adjustable magnitude and optical spectrum output in this article. xenon lamp and halogen tungsten lamp were used as light source. The control of spectrum band and temperature of star was realized with different multi-beam narrow band spectrum with light of varying intensity. When light source with different spectral characteristics and color temperature go into the magnitude regulator, the light energy attenuation were under control by adjusting the light luminosity. This method can completely satisfy the requirements of calibration single star simulator with adjustable magnitude and optical spectrum output in order to achieve the adjustable purpose of magnitude and spectrum.

  18. Design of single-longitudinal-mode laser oscillator for edge Thomson scattering system in ITER

    International Nuclear Information System (INIS)

    Hatae, Takaki; Kusama, Yoshinori; Kubomura, Hiroyuki; Matsuoka, Shin-ichi

    2006-06-01

    A high output energy (5J) and high repetition rate (100 Hz) laser system is required for the edge Thomson scattering system in ITER. A YAG laser (Nd:YAG laser) is a first candidate for the laser system satisfying the requirements. It is important to develop a high beam quality and single longitudinal mode (SLM) laser oscillator in order to realize this high power laser system. In this design work, following activities relating to the SLM laser oscillator have been carried out: design of the laser head and the resonator, estimation of the output power for the SLM laser oscillator, consideration of the feedback control scheme and consideration of interface for amplification system to achieve required performance (5J, 100 Hz). It is expected that the designed laser diode (LD) pumped SLM laser oscillator realizes: 100 Hz of repetition rate, 10 mJ of output energy, 10 ns of pulse width, single longitudinal mode, TEM 00 of transversal mode, divergence less than 4 times of the diffraction limit, energy stability within 5%. (author)

  19. A design of a high speed dual spectrometer by single line scan camera

    Science.gov (United States)

    Palawong, Kunakorn; Meemon, Panomsak

    2018-03-01

    A spectrometer that can capture two orthogonal polarization components of s light beam is demanded for polarization sensitive imaging system. Here, we describe the design and implementation of a high speed spectrometer for simultaneous capturing of two orthogonal polarization components, i.e. vertical and horizontal components, of light beam. The design consists of a polarization beam splitter, two polarization-maintain optical fibers, two collimators, a single line-scan camera, a focusing lens, and a reflection blaze grating. The alignment of two beam paths was designed to be symmetrically incident on the blaze side and reverse blaze side of reflection grating, respectively. The two diffracted beams were passed through the same focusing lens and focused on the single line-scan sensors of a CMOS camera. The two spectra of orthogonal polarization were imaged on 1000 pixels per spectrum. With the proposed setup, the amplitude and shape of the two detected spectra can be controlled by rotating the collimators. The technique for optical alignment of spectrometer will be presented and discussed. The two orthogonal polarization spectra can be simultaneously captured at a speed of 70,000 spectra per second. The high speed dual spectrometer can simultaneously detected two orthogonal polarizations, which is an important component for the development of polarization-sensitive optical coherence tomography. The performance of the spectrometer have been measured and analyzed.

  20. Single shot trajectory design for region-specific imaging using linear and nonlinear magnetic encoding fields.

    Science.gov (United States)

    Layton, Kelvin J; Gallichan, Daniel; Testud, Frederik; Cocosco, Chris A; Welz, Anna M; Barmet, Christoph; Pruessmann, Klaas P; Hennig, Jürgen; Zaitsev, Maxim

    2013-09-01

    It has recently been demonstrated that nonlinear encoding fields result in a spatially varying resolution. This work develops an automated procedure to design single-shot trajectories that create a local resolution improvement in a region of interest. The technique is based on the design of optimized local k-space trajectories and can be applied to arbitrary hardware configurations that employ any number of linear and nonlinear encoding fields. The trajectories designed in this work are tested with the currently available hardware setup consisting of three standard linear gradients and two quadrupolar encoding fields generated from a custom-built gradient insert. A field camera is used to measure the actual encoding trajectories up to third-order terms, enabling accurate reconstructions of these demanding single-shot trajectories, although the eddy current and concomitant field terms of the gradient insert have not been completely characterized. The local resolution improvement is demonstrated in phantom and in vivo experiments. Copyright © 2012 Wiley Periodicals, Inc.

  1. The effect of single oral doses of duloxetine, reboxetine, and midodrine on the urethral pressure in healthy female subjects, using urethral pressure reflectometry

    DEFF Research Database (Denmark)

    Klarskov, Niels; Cerneus, Dirk; Sawyer, William

    2018-01-01

    AIMS: To evaluate the effect on urethral pressure of reference drugs known to reduce stress urinary incontinence symptoms by different effect size and mechanisms of action on urethral musculature under four test conditions in healthy female subjects using urethral pressure reflectometry. METHODS......: Healthy females aged 18-55 years were recruited by advertising for this phase 1, single site, placebo-controlled, randomized, four-period, crossover study. The interventions were single oral doses of 10 mg Midodrine, 80 mg Duloxetine, 12 mg Reboxetine, and placebo. The endpoints were the opening urethral...... pressure measured in each period at four time points (predose and 2, 5.5, and 9 h after dosing). RESULTS: Twenty-nine females were enrolled; 25 randomized and 24 completed the study. The opening urethral pressure was higher in all measurements with filled bladder compared with empty bladder, and during...

  2. Investigation of single lateral mode for 852nm diode lasers with ridge waveguide design

    Science.gov (United States)

    Liu, Chu; Guan, Baolu; Mi, Guoxin; Liao, Yiru; Liu, Zhenyang; Li, Jianjun; Xu, Chen

    2016-11-01

    852nm Narrow linewidth lasers can be widely used in the field of ultra-fine spectrum measurement, Cs atomic clock control, satellite and optical fiber communication and so on. Furthermore, the stability of the single lateral mode is a very important condition to guarantee the narrow linewidth lasers. Here we investigate experimentally the influence of the narrow ridge structure and asymmetrical waveguide design on the stability single lateral mode of an 852nm diode laser. According to the waveguide theoretical analysis, ridge mesa etch depth (Δη , related to the refractive index difference of parallel to the junction) and ridge mesa width (the narrower the more control force to low order mode) are the main elements for lateral modes. In this paper, we designed different structures to investigate and verify major factors for lateral mode by experiment, and to confirm our thought. Finally, the 5μm mesa ridge laser, 800nm etch depth, with groove structure obtains excellent steady single lateral mode output by 150mA operating current and 30°C temperature. The optical spectrum FWHM is 0.5nm and side mode suppression ratio is 27dBm with uncoated. The laser with 1mm cavity length showed the threshold current of 50mA, a lasing wavelength of λ = 852.6nm, slope efficiency of above 0.7mW/mA. We accomplished single lateral mode of ridge waveguide edge-emitting lasers which can also be used as a laser source in the ultra-narrow linewidth external cavity laser system.

  3. Use of trunk stabilization and locomotor training in an adult with cerebellar ataxia: a single system design.

    Science.gov (United States)

    Freund, Jane E; Stetts, Deborah M

    2010-10-01

    The purpose of this study is to describe the effects of trunk stabilization training and locomotor training (LT) using body-weight support on a treadmill (BWST) and overground walking on balance, gait, self-reported function, and trunk muscle performance in an adult with severe ataxia secondary to brain injury. There are no studies on the effectiveness of these combined interventions in persons with ataxia. The subject was a 23-year-old male who had a traumatic brain injury 13 months prior. An A-B-A withdrawal single-system design was used. Outcome measures were Berg Balance Test (BBT), timed unsupported stance, Functional Ambulation Category (FAC), 10-meter walk test (10-MWT), Outpatient Physical Therapy Improvement in Movement Assessment Log (OPTIMAL), transverse abdominis (TrA) thickness, and isometric trunk endurance tests. Performance on the BBT, timed unsupported stance, FAC, 10-MWT, and OPTIMAL each improved after 10 weeks of intervention. In additions, TrA symmetry at rest improved as did right side-bridge endurance time. LT, using BWST and overground walking, and trunk stabilization training may be effective in improving balance, gait, function, and trunk performance in individuals with severe ataxia. Further research with additional subjects is indicated.

  4. Design of a test device for subjecting materials to high strain rates: with application in nuclear area

    Energy Technology Data Exchange (ETDEWEB)

    Todesco, Sergio R.; Mucsi, Cristiano S.; Rossi, Jesualdo L., E-mail: sergio.todesco@usp.br, E-mail: csmucsi@ipen.br, E-mail: jelrossi@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    This paper presents a design of a device to gather characteristic data of materials subjected to high strain rates, this device named after the eminent English engineer Sir Bertram Hopkinson 'Split Hopkinson Pressure Bar', from here will be designated SHPB. More specifically, this work is inseparably linked to the development of packing for transportation of highly radioactive substances as a part to the general scope of a CAPES project in partnership with the CCTM Materials Department of IPEN, Institute of Energy and Nuclear Research, linked to the University of Sao Paulo. The development of the device is part of a scope, and collection of data necessary for the design and construction of this packing. The SHPB device can be divided into two parts, the first part concerning the mechanical design. The second, data collection that is indeed the challenging part of the device, and proper tests. The present paper, specifically, will only deals with the mechanical design of the device, importantly, divided into two parts, the size of the bars, which are the impact bar, the input bar, and the output bar, and the size of the impact device. The sizing of the bars involve knowledge of the concept of elastic waves in solid media for the length of the bars to serve as a wave-guide, which will cause a deformation of the specimen, and enables recording of these waves for data analysis. The impact device must be robust enough to produce the stress wave to deform the specimen, but not to plastically deform the bars, which have to continue throughout the test within the elastic range. (author)

  5. Design of a test device for subjecting materials to high strain rates: with application in nuclear area

    International Nuclear Information System (INIS)

    Todesco, Sergio R.; Mucsi, Cristiano S.; Rossi, Jesualdo L.

    2015-01-01

    This paper presents a design of a device to gather characteristic data of materials subjected to high strain rates, this device named after the eminent English engineer Sir Bertram Hopkinson 'Split Hopkinson Pressure Bar', from here will be designated SHPB. More specifically, this work is inseparably linked to the development of packing for transportation of highly radioactive substances as a part to the general scope of a CAPES project in partnership with the CCTM Materials Department of IPEN, Institute of Energy and Nuclear Research, linked to the University of Sao Paulo. The development of the device is part of a scope, and collection of data necessary for the design and construction of this packing. The SHPB device can be divided into two parts, the first part concerning the mechanical design. The second, data collection that is indeed the challenging part of the device, and proper tests. The present paper, specifically, will only deals with the mechanical design of the device, importantly, divided into two parts, the size of the bars, which are the impact bar, the input bar, and the output bar, and the size of the impact device. The sizing of the bars involve knowledge of the concept of elastic waves in solid media for the length of the bars to serve as a wave-guide, which will cause a deformation of the specimen, and enables recording of these waves for data analysis. The impact device must be robust enough to produce the stress wave to deform the specimen, but not to plastically deform the bars, which have to continue throughout the test within the elastic range. (author)

  6. Design and performance of single photon APD focal plane arrays for 3-D LADAR imaging

    Science.gov (United States)

    Itzler, Mark A.; Entwistle, Mark; Owens, Mark; Patel, Ketan; Jiang, Xudong; Slomkowski, Krystyna; Rangwala, Sabbir; Zalud, Peter F.; Senko, Tom; Tower, John; Ferraro, Joseph

    2010-08-01

    ×We describe the design, fabrication, and performance of focal plane arrays (FPAs) for use in 3-D LADAR imaging applications requiring single photon sensitivity. These 32 × 32 FPAs provide high-efficiency single photon sensitivity for three-dimensional LADAR imaging applications at 1064 nm. Our GmAPD arrays are designed using a planarpassivated avalanche photodiode device platform with buried p-n junctions that has demonstrated excellent performance uniformity, operational stability, and long-term reliability. The core of the FPA is a chip stack formed by hybridizing the GmAPD photodiode array to a custom CMOS read-out integrated circuit (ROIC) and attaching a precision-aligned GaP microlens array (MLA) to the back-illuminated detector array. Each ROIC pixel includes an active quenching circuit governing Geiger-mode operation of the corresponding avalanche photodiode pixel as well as a pseudo-random counter to capture per-pixel time-of-flight timestamps in each frame. The FPA has been designed to operate at frame rates as high as 186 kHz for 2 μs range gates. Effective single photon detection efficiencies as high as 40% (including all optical transmission and MLA losses) are achieved for dark count rates below 20 kHz. For these planar-geometry diffused-junction GmAPDs, isolation trenches are used to reduce crosstalk due to hot carrier luminescence effects during avalanche events, and we present details of the crosstalk performance for different operating conditions. Direct measurement of temporal probability distribution functions due to cumulative timing uncertainties of the GmAPDs and ROIC circuitry has demonstrated a FWHM timing jitter as low as 265 ps (standard deviation is ~100 ps).

  7. Single Event Upset Energy Dependence In a Buck-Converter Power Supply Design

    CERN Document Server

    Drake, G; The ATLAS collaboration; De Lurgio, P; Stanek, R; Mellado, B; Gopalakrishnan, A; Mahadik, S; Reed, R; Senthilkumaran, A

    2012-01-01

    We present a study of Single Event Upsets performed on a commercial pulse-width modulator controller chip that we are using for a switching power supply design for the Atlas Tile Calorimeter at the LHC. We performed tests to study the probability of an SEU occurring as a function of incident particle (hadron) energy. We compare the results with prediction from theory. We discuss the performance of the circuit, and perform an analysis using Bendel parameters. We also present a solution that we found using external circuitry that eliminates the effect.

  8. Optimized design and performance of a shared pump single clad 2 μm TDFA

    Science.gov (United States)

    Tench, Robert E.; Romano, Clément; Delavaux, Jean-Marc

    2018-05-01

    We report the design, experimental performance, and simulation of a single stage, co- and counter-pumped Tm-doped fiber amplifier (TDFA) in the 2 μm signal wavelength band with an optimized 1567 nm shared pump source. We investigate the dependence of output power, gain, and efficiency on pump coupling ratio and signal wavelength. Small signal gains of >50 dB, an output power of 2 W, and small signal noise figures of performance agree well with the experimental data. We also discuss performance tradeoffs with respect to amplifier topology for this simple and efficient TDFA.

  9. Modeling and Design of High-Efficiency Single-Photon Sources

    DEFF Research Database (Denmark)

    Gregersen, Niels; Nielsen, Per Kær; Mørk, Jesper

    2013-01-01

    be electrically driven. Several design strategies addressing these requirements have been proposed. In the cavity-based source, light emission is controlled using resonant cavity quantum electrodynamics effects, whereas in the waveguide-based source, broadband electric field screening effects are employed......Solid-state sources capable of emitting single photons on demand are of great interest in quantum information applications. Ideally, such a source should emit exactly one photon into the collection optics per trigger, the emitted photons should be indistinguishable, and the source should...

  10. Design and simulation of ion optics for ion sources for production of singly charged ions

    Science.gov (United States)

    Zelenak, A.; Bogomolov, S. L.

    2004-05-01

    During the last 2 years different types of the singly charged ion sources were developed for FLNR (JINR) new projects such as Dubna radioactive ion beams, (Phase I and Phase II), the production of the tritium ion beam and the MASHA mass separator. The ion optics simulations for 2.45 GHz electron cyclotron resonance source, rf source, and the plasma ion source were performed. In this article the design and simulation results of the optics of new ion sources are presented. The results of simulation are compared with measurements obtained during the experiments.

  11. Design and simulation of ion optics for ion sources for production of singly charged ions

    International Nuclear Information System (INIS)

    Zelenak, A.; Bogomolov, S.L.

    2004-01-01

    During the last 2 years different types of the singly charged ion sources were developed for FLNR (JINR) new projects such as Dubna radioactive ion beams, (Phase I and Phase II), the production of the tritium ion beam and the MASHA mass separator. The ion optics simulations for 2.45 GHz electron cyclotron resonance source, rf source, and the plasma ion source were performed. In this article the design and simulation results of the optics of new ion sources are presented. The results of simulation are compared with measurements obtained during the experiments

  12. MECHANISM FOR DESIGNING COMPETENCE-ORIENTED TASKS IN VARIOUS ACADEMIC SUBJECTS AND REQUIREMENTS FOR ITS IMPLEMENTATION IN HIGHER EDUCATIONAL ESTABLISHMENTS

    Directory of Open Access Journals (Sweden)

    Natalya M. Zhukova

    2015-01-01

    Full Text Available The research objective is to develop a mechanism for designing competence-oriented tasks in various academic subjects and requirements for its implementation in higher educational establishments. Methods. The authors conducted a theoretical analysis of philosophical, psychological and pedagogical literature sources on the research issues to implement the objectives of the study; Russian and foreign educational experience on the use of study tasks in the study process is studied and summarized; educational and syllabus documentation and training materials are analyzed (syllabi, textbooks, manuals, task and exercise books, etc.; normative documents are studied (State Educational Standards, Federal State Educational Standards, Main Syllabi, curricula, instructional acts, etc.. Empirical research methods involve observation, testing, questioning, modeling, peer review, pedagogical experiment and statistical interpretation of the study results. The study was carried out from 2007 to 2012 in the Engineering-Pedagogical Faculty of Moscow State Agroengineering Goryachkin University. 240 students were engaged in the pedagogical experiment. The following Moscow colleges provided facilities for the peer review of the list and solution frequency of vocational education tasks by secondary vocational school teachers: Colleges of Civil Engineering No 1 and No 12, Small Business College No 48, Polytechnic College No 13, Printing and Publishing College No 56, and Electromechanical College No 55. Results. The research findings demonstrate that the competence-oriented tasks are shown as an integrative didactic unit of professional competence development. Its functions, classification, and structural components are given. The mechanism of designing competence-oriented tasks in various academic subjects is developed and tested. The proposed mechanism is an invariant for academic and teaching staff of educational establishments at all levels of professional

  13. ICU architectural design affects the delirium prevalence: a comparison between single-bed and multibed rooms*.

    Science.gov (United States)

    Caruso, Pedro; Guardian, Lilian; Tiengo, Tatiane; Dos Santos, Lucio Souza; Junior, Pedro Medeiros

    2014-10-01

    Delirium risk factors are related to the patients' acute and chronic clinical condition, treatment, and environment. The environmental risk factors are essentially determined by the ICU architectural design. Although there are countless architectural variations among the ICUs, all can be classified as single- or multibed rooms. Our objectives were to compare the ICU delirium prevalence and characteristics (coma/delirium-free days, first day in delirium, and delirium motoric subtypes) of critically ill patients admitted in single- or multibed rooms. Retrospective. ICU of a teaching oncologic hospital with 31 beds. Twenty-three beds distributed in one multibed room with 13 beds and other with 10 beds. Eight beds distributed in single-bed rooms. All adult patients admitted from February to November 2011. None. We evaluated 1,587 patients and included 1,253 patients. Patients' characteristics at ICU admission and their outcomes along the ICU stay were not different between patients admitted in single- or multibed rooms. One hundred sixty-three patients (13.0%) had delirium, and the prevalence was significantly lower in patients admitted in single-bed rooms (6.8% × 15.1%; p < 0.01). This lower prevalence occurred in patients admitted due to a medical (11.0% × 25.6%; p < 0.01) or postoperative (5.0% × 11.4%; p < 0.01) reason. However, the coma/delirium-free days, the first day in delirium, and the delirium motoric subtypes were not different between the single- and multibed rooms. The risk factors associated with delirium were admission in multibed rooms (odds ratio, 4.03; 95% CI, 2.13-7.62), older age, ICU-acquired infection, and higher Simplified Acute Physiology Score 3 and Sequential Organ Failure Assessment score. Critically ill patients admitted in single-bed rooms have a lower prevalence of delirium than those admitted in multibed rooms. However, coma/delirium-free days, first day in delirium, and motoric subtypes were not different.

  14. Data mining for materials design: A computational study of single molecule magnet

    Energy Technology Data Exchange (ETDEWEB)

    Dam, Hieu Chi [Japan Advanced Institute of Science and Technology, 1-1 Asahidai, Nomi, Ishikawa 923-1292 (Japan); Faculty of Physics, Vietnam National University, 334 Nguyen Trai, Hanoi (Viet Nam); Pham, Tien Lam; Ho, Tu Bao [Japan Advanced Institute of Science and Technology, 1-1 Asahidai, Nomi, Ishikawa 923-1292 (Japan); Nguyen, Anh Tuan [Faculty of Physics, Vietnam National University, 334 Nguyen Trai, Hanoi (Viet Nam); Nguyen, Viet Cuong [HPC Systems, Inc., 3-9-15 Kaigan, Minato-ku, Tokyo 108-0022 (Japan)

    2014-01-28

    We develop a method that combines data mining and first principles calculation to guide the designing of distorted cubane Mn{sup 4+} Mn {sub 3}{sup 3+} single molecule magnets. The essential idea of the method is a process consisting of sparse regressions and cross-validation for analyzing calculated data of the materials. The method allows us to demonstrate that the exchange coupling between Mn{sup 4+} and Mn{sup 3+} ions can be predicted from the electronegativities of constituent ligands and the structural features of the molecule by a linear regression model with high accuracy. The relations between the structural features and magnetic properties of the materials are quantitatively and consistently evaluated and presented by a graph. We also discuss the properties of the materials and guide the material design basing on the obtained results.

  15. Conceptual Design of a Single Phase 33 MVA HTS Transformer with a Tertiary Winding

    International Nuclear Information System (INIS)

    Lee, S. W.; Kim, W. S.; Hahn, S. Y.; Hwang, Y. I.; Choi, K. D.

    2006-01-01

    We have proposed a 3 phase, 100 MVA, 154 kV class HTS transformer substituting for a 60 MVA conventional transformer. The power transformer of 154 kV class has a tertiary winding besides primary and secondary windings. So the HTS transformer should have the 3rd superconducting winding. In this paper, we designed conceptually the structure of the superconducting windings of a single phase 33 MVA transformer. The electrical characteristics of the HTS transformer such as % impedance and AC loss vary with the arrangement of the windings and gaps between windings. We analyzed the effects of the winding parameters, evaluated the cost of each design, and proposed a suitable HTS transformer model for future power distribution system.

  16. The design and analysis of single flank transmission error testor for loaded gears

    Science.gov (United States)

    Houser, D. R.; Bassett, D. E.

    1985-01-01

    Due to geometrical imperfections in gears and finite tooth stiffnesses, the motion transmitted from an input gear shaft to an output gear shaft will not have conjugate action. In order to strengthen the understanding of transmission error and to verify mathematical models of gear transmission error, a test stand that will measure the transmission error of a gear pair at operating loads, but at reduced speeds would be desirable. This document describes the design and development of a loaded transmission error tester. For a gear box with a gear ratio of one, few tooth meshing combinations will occur during a single test. In order to observe the effects of different tooth mesh combinations and to increase the ability to load test gear pairs with higher gear ratios, the system was designed around a gear box with a gear ratio of two.

  17. Single-well experimental design for studying residual trapping of superciritcal carbon dioxide

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Y.; Freifeld, B.; Finsterle, S.; Leahy, M.; Ennis-King, J.; Paterson, L.; Dance, T.

    2010-06-15

    The objective of our research is to design a single-well injection-withdrawal test to evaluate residual phase trapping at potential CO{sub 2} geological storage sites. Given the significant depths targeted for CO{sub 2} storage and the resulting high costs associated with drilling to those depths, it is attractive to develop a single-well test that can provide data to assess reservoir properties and reduce uncertainties in the appraisal phase of site investigation. The main challenges in a single-well test design include (1) difficulty in quantifying the amount of CO{sub 2} that has dissolved into brine or migrated away from the borehole; (2) non-uniqueness and uncertainty in the estimate of the residual gas saturation (S{sub gr}) due to correlations among various parameters; and (3) the potential biased S{sub gr} estimate due to unaccounted heterogeneity of the geological medium. To address each of these challenges, we propose (1) to use a physical-based model to simulation test sequence and inverse modeling to analyze data information content and to quantify uncertainty; (2) to jointly use multiple data types generated from different kinds of tests to constrain the Sgr estimate; and (3) to reduce the sensitivity of the designed tests to geological heterogeneity by conducting the same test sequence in both a water-saturated system and a system with residual gas saturation. To perform the design calculation, we build a synthetic model and conduct a formal analysis for sensitivity and uncertain quantification. Both parametric uncertainty and geological uncertainty are considered in the analysis. Results show (1) uncertainty in the estimation of Sgr can be reduced by jointly using multiple data types and repeated tests; and (2) geological uncertainty is essential and needs to be accounted for in the estimation of S{sub gr} and its uncertainty. The proposed methodology is applied to the design of a CO{sub 2} injection test at CO2CRC's Otway Project Site, Victoria

  18. Subjective memory impairment in general practice : Short overview and design of a mixed methods study.

    Science.gov (United States)

    Pentzek, Michael; Leve, Verena; Leucht, Verena

    2017-05-01

    Public awareness for dementia is rising and patients with concerns about forgetfulness are not uncommon in general practice. For the general practitioner (GP) subjectively perceived memory impairment (SMI) also offers a chance to broach the issue of cognitive function with the patient. This may support GPs' patient-centered care in terms of a broader frailty concept. What is SMI (definition, operationalization, prevalence and burden)? Which conceptions and approaches do GPs have regarding SMI? Narrative overview of recent SMI criteria and results, selective utilization of results from a systematic literature search on GP dementia care, non-systematic search regarding SMI in general practice, deduction of a study design from the overview and development according to international standards. Studies revealed that approximately 60% of GP patients aged >74 reported a declining memory, every sixth person had concerns about this aspect and only relatively few seek medical advice. Concerns about SMI are considered a risk factor for future dementia. Specific general practice conceptions about SMI could not be identified in the literature. Using guidelines for mixed methods research, the design of an exploratory sequential mixed methods study is presented, which should reveal different attitudes of GPs towards SMI. Subjective memory impairment (SMI) is a common feature and troubles a considerable proportion of patients. Neuropsychiatric research is progressing, but for the transfer of the SMI concept into routine practice, involvement of GP research is necessary. A new study aims to make a contribution to this.

  19. Virtual peer-delivered memory intervention: a single-case experimental design in an adolescent with chronic memory impairment.

    Science.gov (United States)

    Cooper, Janine M; Lockett, Stephen; McIlroy, Alissandra; Gonzalez, Linda

    2018-01-01

    Children and adolescents with chronic memory impairment may develop coping strategies that enable functioning, yet these often remain undetectable using traditional psychometric measures. Personalized intervention studies that promote the use of such strategies designed specifically for use by this young cohort are scarce. To investigate the effect of a novel virtual reality peer-delivered memory intervention on the everyday functioning and well-being of SE, a 17-year-old female with a history of chronic verbal memory issues, impaired autobiographical event recall and elevated mood symptoms. A single-case ABA experimental design study was used to assess change. Following initial baseline assessment using objective neuropsychological and subjective functional questionnaires and intervention training, case SE used the intervention daily for 3 weeks before repeating key outcome measures. Using non-overlap of all pairs and qualitative feedback analysis, the results revealed a significant increase in event recall and self-reported positive changes to levels of everyday functioning. Supporting autobiographical event recall and prospective memory via a virtual peer-delivered intervention may lead to reduction in cognitive load, and benefit overall well-being and everyday functioning.

  20. Validity of single-cycle objective functions for multicycle reload design optimization

    International Nuclear Information System (INIS)

    Kropaczek, D.J.; McElroy, J.; Turinsky, P.J.

    1993-01-01

    Beyond the equilibrium cycle scoping calculations used for determining numbers of feed assemblies and enrichment estimates, multicycle reload design currently consists of stagewise optimization of single-cycle core loading patterns, typically extending over a short-term planning horizon of perhaps three reload cycles. Particularly in transition cycles, however, optimizing a loading pattern over a single cycle for a stated objective, such as minimum core leakage, may have an adverse impact on subsequent cycles. The penalties paid may be in the form of reduced thermal margin or an increase in feed enrichment due to insufficient reactivity carryover from the open-quotes optimizedclose quotes cycle. In view of current practices, a study was performed that examined the behavior of the loading pattern as a function of the objective functions selected as implemented in the stagewise optimization of single-cycle core loading patterns from initial transition cycle through equilibrium using the FORMOSA-P code. The objective functions studied were region average discharge burnup maximization (with enrichment search) and feed enrichment minimization. It is noted at the beginning that the maximization of region average discharge has no meaning for the equilibrium cycle because region average discharge burnup is explicitly set by the feed size and cycle length independent of the loading pattern. In the nonequilibrium cycle, however, it was reasoned that this objective would provide the maximum reactivity carryover throughout the transition and thus have a direct effect on minimizing the multicycle levelized fuel cost

  1. Safety, tolerability and pharmacokinetics of doravirine, a novel HIV non-nucleoside reverse transcriptase inhibitor, after single and multiple doses in healthy subjects.

    Science.gov (United States)

    Anderson, Matt S; Gilmartin, Jocelyn; Cilissen, Caroline; De Lepeleire, Inge; Van Bortel, Luc; Dockendorf, Marissa F; Tetteh, Ernestina; Ancona, June K; Liu, Rachael; Guo, Ying; Wagner, John A; Butterton, Joan R

    2015-01-01

    Doravirine is a novel non-nucleoside inhibitor of HIV-1 reverse transcriptase with potent activity against wild-type virus (95% inhibitory concentration 19 nM, 50% human serum). Doravirine has low potential to cause drug-drug interactions since it is primarily eliminated by oxidative metabolism and does not inhibit or significantly induce drug-metabolizing enzymes. The pharmacokinetics and safety of doravirine were investigated in two double-blind, dose-escalation studies in healthy males. Thirty-two subjects received single doses of doravirine (6-1,200 mg) or matching placebo tablets; 40 subjects received doravirine (30-750 mg) or matching placebo tablets once daily for 10 days. In addition, the effect of doravirine (120 mg for 14 days) on single-dose pharmacokinetics of the CYP3A substrate midazolam was evaluated (10 subjects). The maximum plasma concentration (Cmax) of doravirine was achieved within 1-5 h with an apparent terminal half-life of 12-21 h. Consistent with single-dose pharmacokinetics, steady state was achieved after approximately 7 days of once daily administration, with accumulation ratios (day 10/day 1) of 1.1-1.5 in the area under the plasma concentration-time curve during the dosing interval (AUC0-24 h), Cmax and trough plasma concentration (C24 h). All dose levels produced C24 h>19 nM. Administration of 50 mg doravirine with a high-fat meal was associated with slight elevations in AUC time zero to infinity (AUC0-∞) and C24 h with no change in Cmax. Midazolam AUC0-∞ was slightly reduced by coadministration of doravirine (geometric mean ratio 0.82, 90% CI 0.70, 0.97). There was no apparent relationship between adverse event frequency or intensity and doravirine dose. No rash or significant central nervous system events other than headache were reported. Doravirine is generally well tolerated in single doses up to 1,200 mg and multiple doses up to 750 mg once daily for up to 10 days, with a pharmacokinetic profile supportive of once

  2. Design and analysis of a single stage to orbit nuclear thermal rocket reactor engine

    International Nuclear Information System (INIS)

    Labib, Satira; King, Jeffrey

    2015-01-01

    Graphical abstract: - Highlights: • Three NTR reactors are optimized for the single stage launch of 1–15 MT payloads. • The proposed rocket engines have specific impulses in excess of 700 s. • Reactivity and submersion criticality requirements are satisfied for each reactor. - Abstract: Recent advances in the development of high power density fuel materials have renewed interest in nuclear thermal rockets (NTRs) as a viable propulsion technology for future space exploration. This paper describes the design of three NTR reactor engines designed for the single stage to orbit launch of payloads from 1 to 15 metric tons. Thermal hydraulic and rocket engine analyses indicate that the proposed rocket engines are able to reach specific impulses in excess of 800 s. Neutronics analyses performed using MCNP5 demonstrate that the hot excess reactivity, shutdown margin, and submersion criticality requirements are satisfied for each NTR reactor. The reactors each consist of a 40 cm diameter core packed with hexagonal tungsten cermet fuel elements. The core is surrounded by radial and axial beryllium reflectors and eight boron carbide control drums. The 40 cm long reactor meets the submersion criticality requirements (a shutdown margin of at least $1 subcritical in all submersion scenarios) with no further modifications. The 80 and 120 cm long reactors include small amounts of gadolinium nitride as a spectral shift absorber to keep them subcritical upon submersion in seawater or wet sand following a launch abort

  3. Design and Fabrication of a Single Cusp Magnetic Field Type Hydrogen ion Source

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Su Hun

    1996-02-15

    A single-cusp type hydrogen ion source has been designed and fabricated. In order to increase the efficiency of the plasma production, a single-cusp type magnet circuit and an electrostatic reflector were installed. The Poission Group Code was used to predict the distribution of magnetic field in the plasma chamber. In order to design the accel.-decel. extraction part for forming the ion beam with low emmitance and high current density, EGUN code was used. The results of calculation show that the configuration of plasma electrode strongly affects the beam quality and the deceleration electrode only functions the repression of the electron stream. When the plasma-accel potential is -20kV and an accel.-decel. potential is 1kV, the calculated extraction current, normalized emittance and perveance are 20.6mA, 1.28x 10{sup -7} m {center_dot} rad and 7.87 x 10{sup -9}A {center_dot} V{sup -3/2}, respectively. This study on the improvement of beam quality and the achievement of high ion beam current will contribute to the analysis of fusion plasma and the research on the surface physics.

  4. Design and Fabrication of a Single Cusp Magnetic Field Type Hydrogen ion Source

    International Nuclear Information System (INIS)

    Kim, Su Hun

    1996-02-01

    A single-cusp type hydrogen ion source has been designed and fabricated. In order to increase the efficiency of the plasma production, a single-cusp type magnet circuit and an electrostatic reflector were installed. The Poission Group Code was used to predict the distribution of magnetic field in the plasma chamber. In order to design the accel.-decel. extraction part for forming the ion beam with low emmitance and high current density, EGUN code was used. The results of calculation show that the configuration of plasma electrode strongly affects the beam quality and the deceleration electrode only functions the repression of the electron stream. When the plasma-accel potential is -20kV and an accel.-decel. potential is 1kV, the calculated extraction current, normalized emittance and perveance are 20.6mA, 1.28x 10 -7 m · rad and 7.87 x 10 -9 A · V -3/2 , respectively. This study on the improvement of beam quality and the achievement of high ion beam current will contribute to the analysis of fusion plasma and the research on the surface physics

  5. Design optimization of single mixed refrigerant LNG process using a hybrid modified coordinate descent algorithm

    Science.gov (United States)

    Qyyum, Muhammad Abdul; Long, Nguyen Van Duc; Minh, Le Quang; Lee, Moonyong

    2018-01-01

    Design optimization of the single mixed refrigerant (SMR) natural gas liquefaction (LNG) process involves highly non-linear interactions between decision variables, constraints, and the objective function. These non-linear interactions lead to an irreversibility, which deteriorates the energy efficiency of the LNG process. In this study, a simple and highly efficient hybrid modified coordinate descent (HMCD) algorithm was proposed to cope with the optimization of the natural gas liquefaction process. The single mixed refrigerant process was modeled in Aspen Hysys® and then connected to a Microsoft Visual Studio environment. The proposed optimization algorithm provided an improved result compared to the other existing methodologies to find the optimal condition of the complex mixed refrigerant natural gas liquefaction process. By applying the proposed optimization algorithm, the SMR process can be designed with the 0.2555 kW specific compression power which is equivalent to 44.3% energy saving as compared to the base case. Furthermore, in terms of coefficient of performance (COP), it can be enhanced up to 34.7% as compared to the base case. The proposed optimization algorithm provides a deep understanding of the optimization of the liquefaction process in both technical and numerical perspectives. In addition, the HMCD algorithm can be employed to any mixed refrigerant based liquefaction process in the natural gas industry.

  6. Design and analysis of a single stage to orbit nuclear thermal rocket reactor engine

    Energy Technology Data Exchange (ETDEWEB)

    Labib, Satira, E-mail: Satira.Labib@duke-energy.com; King, Jeffrey, E-mail: kingjc@mines.edu

    2015-06-15

    Graphical abstract: - Highlights: • Three NTR reactors are optimized for the single stage launch of 1–15 MT payloads. • The proposed rocket engines have specific impulses in excess of 700 s. • Reactivity and submersion criticality requirements are satisfied for each reactor. - Abstract: Recent advances in the development of high power density fuel materials have renewed interest in nuclear thermal rockets (NTRs) as a viable propulsion technology for future space exploration. This paper describes the design of three NTR reactor engines designed for the single stage to orbit launch of payloads from 1 to 15 metric tons. Thermal hydraulic and rocket engine analyses indicate that the proposed rocket engines are able to reach specific impulses in excess of 800 s. Neutronics analyses performed using MCNP5 demonstrate that the hot excess reactivity, shutdown margin, and submersion criticality requirements are satisfied for each NTR reactor. The reactors each consist of a 40 cm diameter core packed with hexagonal tungsten cermet fuel elements. The core is surrounded by radial and axial beryllium reflectors and eight boron carbide control drums. The 40 cm long reactor meets the submersion criticality requirements (a shutdown margin of at least $1 subcritical in all submersion scenarios) with no further modifications. The 80 and 120 cm long reactors include small amounts of gadolinium nitride as a spectral shift absorber to keep them subcritical upon submersion in seawater or wet sand following a launch abort.

  7. Design of automatic curtain controlled by wireless based on single chip 51 microcomputer

    Science.gov (United States)

    Han, Dafeng; Chen, Xiaoning

    2017-08-01

    In order to realize the wireless control of the domestic intelligent curtains, a set of wireless intelligent curtain control system based on 51 single chip microcomputer have been designed in this paper. The intelligent curtain can work in the manual mode, automatic mode and sleep mode and can be carried out by the button and mobile phone APP mode loop switch. Through the photosensitive resistance module and human pyroelectric infrared sensor to collect the indoor light value and the data whether there is the person in the room, and then after single chip processing, the motor drive module is controlled to realize the positive inversion of the asynchronous motor, the intelligent opening and closing of the curtain have been realized. The operation of the motor can be stopped under the action of the switch and the curtain opening and closing and timing switch can be controlled through the keys and mobile phone APP. The optical fiber intensity, working mode, curtain state and system time are displayed by LCD1602. The system has a high reliability and security under practical testing and with the popularity and development of smart home, the design has broad market prospects.

  8. Design and Characterization of 64K Pixels Chips Working in Single Photon Processing Mode

    CERN Document Server

    Llopart Cudie, Xavier; Campbell, M

    2007-01-01

    Progress in CMOS technology and in fine pitch bump bonding has made possible the development of high granularity single photon counting detectors for X-ray imaging. This thesis studies the design and characterization of three pulse processing chips with 65536 square pixels of 55 µm x 55 µm designed in a commercial 0.25 µm 6-metal CMOS technology. The 3 chips share the same architecture and dimensions and are named Medipix2, Mpix2MXR20 and Timepix. The Medipix2 chip is a pixel detector readout chip consisting of 256 x 256 identical elements, each working in single photon counting mode for positive or negative input charge signals. The preamplifier feedback provides compensation for detector leakage current on a pixel by pixel basis. Two identical pulse height discriminators are used to define an energy window. Every event falling inside the energy window is counted with a 13 bit pseudo-random counter. The counter logic, based in a shift register, also behaves as the input/output register for the pixel. Each...

  9. Design of an omnidirectional single-point photodetector for large-scale spatial coordinate measurement

    Science.gov (United States)

    Xie, Hongbo; Mao, Chensheng; Ren, Yongjie; Zhu, Jigui; Wang, Chao; Yang, Lei

    2017-10-01

    In high precision and large-scale coordinate measurement, one commonly used approach to determine the coordinate of a target point is utilizing the spatial trigonometric relationships between multiple laser transmitter stations and the target point. A light receiving device at the target point is the key element in large-scale coordinate measurement systems. To ensure high-resolution and highly sensitive spatial coordinate measurement, a high-performance and miniaturized omnidirectional single-point photodetector (OSPD) is greatly desired. We report one design of OSPD using an aspheric lens, which achieves an enhanced reception angle of -5 deg to 45 deg in vertical and 360 deg in horizontal. As the heart of our OSPD, the aspheric lens is designed in a geometric model and optimized by LightTools Software, which enables the reflection of a wide-angle incident light beam into the single-point photodiode. The performance of home-made OSPD is characterized with working distances from 1 to 13 m and further analyzed utilizing developed a geometric model. The experimental and analytic results verify that our device is highly suitable for large-scale coordinate metrology. The developed device also holds great potential in various applications such as omnidirectional vision sensor, indoor global positioning system, and optical wireless communication systems.

  10. Monitoring driver fatigue using a single-channel electroencephalographic device: A validation study by gaze-based, driving performance, and subjective data.

    Science.gov (United States)

    Morales, José M; Díaz-Piedra, Carolina; Rieiro, Héctor; Roca-González, Joaquín; Romero, Samuel; Catena, Andrés; Fuentes, Luis J; Di Stasi, Leandro L

    2017-12-01

    Driver fatigue can impair performance as much as alcohol does. It is the most important road safety concern, causing thousands of accidents and fatalities every year. Thanks to technological developments, wearable, single-channel EEG devices are now getting considerable attention as fatigue monitors, as they could help drivers to assess their own levels of fatigue and, therefore, prevent the deterioration of performance. However, the few studies that have used single-channel EEG devices to investigate the physiological effects of driver fatigue have had inconsistent results, and the question of whether we can monitor driver fatigue reliably with these EEG devices remains open. Here, we assessed the validity of a single-channel EEG device (TGAM-based chip) to monitor changes in mental state (from alertness to fatigue). Fifteen drivers performed a 2-h simulated driving task while we recorded, simultaneously, their prefrontal brain activity and saccadic velocity. We used saccadic velocity as the reference index of fatigue. We also collected subjective ratings of alertness and fatigue, as well as driving performance. We found that the power spectra of the delta EEG band showed an inverted U-shaped quadratic trend (EEG power spectra increased for the first hour and half, and decreased during the last thirty minutes), while the power spectra of the beta band linearly increased as the driving session progressed. Coherently, saccadic velocity linearly decreased and speeding time increased, suggesting a clear effect of fatigue. Subjective data corroborated these conclusions. Overall, our results suggest that the TGAM-based chip EEG device is able to detect changes in mental state while performing a complex and dynamic everyday task as driving. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Relationships between Endogenous Plasma Biomarkers of Constitutive Cytochrome P450 3A Activity and Single-Time-Point Oral Midazolam Microdose Phenotype in Healthy Subjects.

    Science.gov (United States)

    Woolsey, Sarah J; Beaton, Melanie D; Choi, Yun-Hee; Dresser, George K; Gryn, Steven E; Kim, Richard B; Tirona, Rommel G

    2016-04-01

    Due to high basal interindividual variation in cytochrome P450 3A (CYP3A) activity and susceptibility to drug interactions, there has been interest in the application of efficient probe drug phenotyping strategies, as well as endogenous biomarkers for assessment of in vivo CYP3A activity. The biomarkers 4β-hydroxycholesterol (4βHC) and 6β-hydroxycortisol (6βHCL) are sensitive to CYP3A induction and inhibition. However, their utility for the assessment of constitutive CYP3A activity remains uncertain. We investigated whether endogenous plasma biomarkers (4βHC and 6βHCL) are associated with basal CYP3A metabolic activity in healthy subjects assessed by a convenient single-time-point oral midazolam (MDZ) phenotyping strategy. Plasma 4βHC and 6βHCL metabolic ratios (MRs) were analysed in 51 healthy adult participants. CYP3A activity was determined after administration of an oral MDZ microdose (100 μg). Simple linear and multiple linear regression analyses were performed to assess relationships between MDZ oral clearance, biomarkers and subject covariates. Among study subjects, basal MDZ oral clearance, 4βHC and 6βHCL MRs ranged 6.5-, 10- and 13-fold, respectively. Participant age and alcohol consumption were negatively associated with MDZ oral clearance (p = 0.03 and p = 0.045, respectively), while weight and female sex were associated with lower plasma 4βHC MR (p = 0.0003 and p = 0.032, respectively). Neither 4βHC nor 6βHCL MRs were associated with MDZ oral clearance. Plasma 4βHC and 6βHCL MRs do not relate to MDZ single-time-point metabolic phenotype in the assessment of constitutive CYP3A activity among healthy individuals. © 2015 Nordic Association for the Publication of BCPT (former Nordic Pharmacological Society).

  12. Reinforcement-Learning-Based Robust Controller Design for Continuous-Time Uncertain Nonlinear Systems Subject to Input Constraints.

    Science.gov (United States)

    Liu, Derong; Yang, Xiong; Wang, Ding; Wei, Qinglai

    2015-07-01

    The design of stabilizing controller for uncertain nonlinear systems with control constraints is a challenging problem. The constrained-input coupled with the inability to identify accurately the uncertainties motivates the design of stabilizing controller based on reinforcement-learning (RL) methods. In this paper, a novel RL-based robust adaptive control algorithm is developed for a class of continuous-time uncertain nonlinear systems subject to input constraints. The robust control problem is converted to the constrained optimal control problem with appropriately selecting value functions for the nominal system. Distinct from typical action-critic dual networks employed in RL, only one critic neural network (NN) is constructed to derive the approximate optimal control. Meanwhile, unlike initial stabilizing control often indispensable in RL, there is no special requirement imposed on the initial control. By utilizing Lyapunov's direct method, the closed-loop optimal control system and the estimated weights of the critic NN are proved to be uniformly ultimately bounded. In addition, the derived approximate optimal control is verified to guarantee the uncertain nonlinear system to be stable in the sense of uniform ultimate boundedness. Two simulation examples are provided to illustrate the effectiveness and applicability of the present approach.

  13. Safety, tolerability, pharmacokinetics and pharmacodynamics of single doses of empagliflozin, a sodium glucose cotransporter 2 (SGLT2) inhibitor, in healthy Japanese subjects.

    Science.gov (United States)

    Sarashina, Akiko; Koiwai, Kazuki; Seman, Leo J; Yamamura, Norio; Taniguchi, Atsushi; Negishi, Takahiro; Sesoko, Shogo; Woerle, Hans J; Dugi, Klaus A

    2013-01-01

    This randomized, placebo-controlled within dose groups, double-blind, single rising dose study investigated the safety, tolerability, pharmacokinetics and pharmacodynamics of 1 mg to 100 mg doses of empagliflozin in 48 healthy Japanese male subjects. Empagliflozin was rapidly absorbed, reaching peak levels in 1.25 to 2.50 h; thereafter, plasma concentrations declined in a biphasic fashion, with mean terminal elimination half-life ranging from 7.76 to 11.7 h. Increase in empagliflozin exposure was proportional to dose. Oral clearance was dose independent and ranged from 140 to 172 mL/min. In the 24 h following 100 mg empagliflozin administration, the mean (%CV) amount of glucose excreted in urine was 74.3 (17.1) g. The amount and the maximum rate of glucose excreted via urine increased with dose of empagliflozin. Nine adverse events, all of mild intensity, were reported by 8 subjects (7 with empagliflozin and 1 with the placebo). No hypoglycemia was reported. In conclusion, 1 mg to 100 mg doses of empagliflozin had a good safety and tolerability profile in healthy Japanese male subjects. Exposure to empagliflozin was dose proportional. The amount and rate of urinary glucose excretion were higher with empagliflozin than with the placebo, and increased with empagliflozin dose.

  14. Optimization of single-walled carbon nanotube solubility by noncovalent PEGylation using experimental design methods

    Directory of Open Access Journals (Sweden)

    Hadidi N

    2011-04-01

    Full Text Available Naghmeh Hadidi1, Farzad Kobarfard2, Nastaran Nafissi-Varcheh3, Reza Aboofazeli11Department of Pharmaceutics, 2Department of Pharmaceutical Chemistry, 3Department of Pharmaceutical Biotechnology, School of Pharmacy, Shaheed Beheshti University of Medical Sciences, Tehran, IranAbstract: In this study, noncovalent functionalization of single-walled carbon nanotubes (SWCNTs with phospholipid-polyethylene glycols (Pl-PEGs was performed to improve the solubility of SWCNTs in aqueous solution. Two kinds of PEG derivatives, ie, Pl-PEG 2000 and Pl-PEG 5000, were used for the PEGylation process. An experimental design technique (D-optimal design and second-order polynomial equations was applied to investigate the effect of variables on PEGylation and the solubility of SWCNTs. The type of PEG derivative was selected as a qualitative parameter, and the PEG/SWCNT weight ratio and sonication time were applied as quantitative variables for the experimental design. Optimization was performed for two responses, aqueous solubility and loading efficiency. The grafting of PEG to the carbon nanostructure was determined by thermogravimetric analysis, Raman spectroscopy, and scanning electron microscopy. Aqueous solubility and loading efficiency were determined by ultraviolet-visible spectrophotometry and measurement of free amine groups, respectively. Results showed that Pl-PEGs were grafted onto SWCNTs. Aqueous solubility of 0.84 mg/mL and loading efficiency of nearly 98% were achieved for the prepared Pl-PEG 5000-SWCNT conjugates. Evaluation of functionalized SWCNTs showed that our noncovalent functionalization protocol could considerably increase aqueous solubility, which is an essential criterion in the design of a carbon nanotube-based drug delivery system and its biodistribution.Keywords: phospholipid-PEG, D-optimal design, loading efficiency, Raman spectroscopy, scanning electron microscopy, theromogravimetric analysis, carbon nanotubes

  15. Assessment of cerebral perfusion with single-photon emission tomography in normal subjects and in patients with Alzheimer's disease: effects of region of interest selection

    Energy Technology Data Exchange (ETDEWEB)

    Claus, J J [Dept. of Neurology, Univ. Hospital, Rotterdam (Netherlands) Dept. of Epidemiology and Biostatistics, Erasmus Univ. Medical School, Rotterdam (Netherlands); Harskamp, F van [Dept. of Neurology, Univ. Hospital, Rotterdam (Netherlands); Breteler, M M.B. [Dept. of Epidemiology and Biostatistics, Erasmus Univ. Medical School, Rotterdam (Netherlands); Krenning, E P [Dept. of Nuclear Medicine, Univ. Hospital, Rotterdam (Netherlands); Cammen, T.J.M. van der (Dept. of Geriatric Medicine, Univ. Hospital, Rotterdam (Netherlands)); Hofman, A [Dept. of Epidemiology and Biostatistics, Erasmus Univ. Medical School, Rotterdam (Netherlands); Hasan, D [Dept. of Neurology, Univ. Hospital, Rotterdam (Netherlands)

    1994-10-01

    We compared three different ROIs in a SPET study with 60 controls and in 48 patients with probable Alzheimer's disease diagnosed according to the NINCDS-ADRDA criteria. Regional cerebral blood flow (rCBF) was assessed with SPET using technetium-99m d,l-hexamethylpropylene amine oxime ([sup 99m]Tc-HMPAO), normalized to the mean activity in a cerebellar reference slice. The three different ROIs were: a multi-slice and a single-slice ROI with reference to the normal brain anatomy (using an anatomical atlas), and a rectangular (2x4 pixels) ROI in the frontal, temporal, temporoparietal and occipital cortices. No differences were observed for the means of rCBF values between the single-slice and multi-slice ROI's with reference to the normal anatomy, but some variability was present for individual comparisons. In contrast, significantly higher mean rCBF values were obtained with the single-slice rectangular ROIs in all four regions for both patients and controls and considerable variability was shown for individual subjects. After analysis with multivariate logistic regression and receiver operator characteristic curves, the ability of SPET to discriminate between controls and Alzheimer patients was similar in the three methods for mild and moderate Alzheimer patients (Global Deterioration Scale = GDS of 3 and 4). However, with increasing dementia severity (GDS>4) the rectangular ROIs showed lower ability to discriminate between groups compared to the single-slice and multi-slice anatomically defined ROIs. This study suggests that results of rCBF assessment with SPET using [sup 99m]Tc-HMPAO in patients with severe Alzheimer's disease are influenced by the shape and size of the ROI. (orig.)

  16. Assessment of cerebral perfusion with single-photon emission tomography in normal subjects and in patients with Alzheimer's disease: effects of region of interest selection

    International Nuclear Information System (INIS)

    Claus, J.J.; Harskamp, F. van; Breteler, M.M.B.; Krenning, E.P.; Cammen, T.J.M. van der; Hofman, A.; Hasan, D.

    1994-01-01

    We compared three different ROIs in a SPET study with 60 controls and in 48 patients with probable Alzheimer's disease diagnosed according to the NINCDS-ADRDA criteria. Regional cerebral blood flow (rCBF) was assessed with SPET using technetium-99m d,l-hexamethylpropylene amine oxime ( 99m Tc-HMPAO), normalized to the mean activity in a cerebellar reference slice. The three different ROIs were: a multi-slice and a single-slice ROI with reference to the normal brain anatomy (using an anatomical atlas), and a rectangular (2x4 pixels) ROI in the frontal, temporal, temporoparietal and occipital cortices. No differences were observed for the means of rCBF values between the single-slice and multi-slice ROI's with reference to the normal anatomy, but some variability was present for individual comparisons. In contrast, significantly higher mean rCBF values were obtained with the single-slice rectangular ROIs in all four regions for both patients and controls and considerable variability was shown for individual subjects. After analysis with multivariate logistic regression and receiver operator characteristic curves, the ability of SPET to discriminate between controls and Alzheimer patients was similar in the three methods for mild and moderate Alzheimer patients (Global Deterioration Scale = GDS of 3 and 4). However, with increasing dementia severity (GDS>4) the rectangular ROIs showed lower ability to discriminate between groups compared to the single-slice and multi-slice anatomically defined ROIs. This study suggests that results of rCBF assessment with SPET using 99m Tc-HMPAO in patients with severe Alzheimer's disease are influenced by the shape and size of the ROI. (orig.)

  17. Design of flapping wings for application to single active degree of freedom micro air vehicles

    Science.gov (United States)

    Chang, Kelvin Thomas

    This dissertation covers an experimental program to understand how wing compliance influences the performance of flapping micro air vehicle wings. The focus is the design of a membraned flapping wing for a single active degree of freedom mechanism, looking to maximize thrust performance in hover conditions. The optimization approach is unique in that experiments were the chosen engine as opposed to a computation model; this is because of the complexity involved in hover-mode flapping aerodynamics. The flapping mechanism and manufacturing process for fabricating the wings were carefully developed. The uncertainty in the thrust measurement was identified and reduced by implementing precision machining and repeatable techniques for fabrication. This resulted in a reduction of the manufacturing coefficient of variation from 16.8% to 2.6%. Optimization was then conducted for a single objective (Maximize thrust), using a three parameter design space, finding the highest thrust performance in wings with high aspect ratio; then, a multi-objective optimization was conducted with two objectives (Thrust and Power) and a four parameter space. The research then shifted focus to identifying the stiffness and deformation characteristics of high performance wing designs. Static stiffness measurements with a simple line load suggested that high chordwise stiffness or lower spanwise stiffness would be favorable for aerodynamic performance. To explore more components of the deformation, a full-field imaging technique was used and a uniform load was substituted to engage with the membrane. It was found that there is a range of torsional compliance where the wing is most efficient especially at higher flapping frequencies. The final component of the study was the dynamic deformation measurement. The two system, four camera digital image correlation setup uses stroboscopic measurement to capture the wing deformation. The phase shift between the twist and stroke, and the tip deflection

  18. Analysis of Turbofan Design Options for an Advanced Single-Aisle Transport Aircraft

    Science.gov (United States)

    Guynn, Mark D.; Berton, Jeffrey J.; Fisher, Kenneth L.; Haller, William J.; Tong, Michael T.; Thurman, Douglas R.

    2009-01-01

    The desire for higher engine efficiency has resulted in the evolution of aircraft gas turbine engines from turbojets, to low bypass ratio, first generation turbofans, to today's high bypass ratio turbofans. It is possible that future designs will continue this trend, leading to very-high or ultra-high bypass ratio (UHB) engines. Although increased bypass ratio has clear benefits in terms of propulsion system metrics such as specific fuel consumption, these benefits may not translate into aircraft system level benefits due to integration penalties. In this study, the design trade space for advanced turbofan engines applied to a single-aisle transport (737/A320 class aircraft) is explored. The benefits of increased bypass ratio and associated enabling technologies such as geared fan drive are found to depend on the primary metrics of interest. For example, bypass ratios at which fuel consumption is minimized may not require geared fan technology. However, geared fan drive does enable higher bypass ratio designs which result in lower noise. Regardless of the engine architecture chosen, the results of this study indicate the potential for the advanced aircraft to realize substantial improvements in fuel efficiency, emissions, and noise compared to the current vehicles in this size class.

  19. Design of a Facility for Studying Shock-Cell Noise on Single and Coaxial Jets

    Directory of Open Access Journals (Sweden)

    Daniel Guariglia

    2018-03-01

    Full Text Available Shock-cell noise occurs in aero-engines when the nozzle exhaust is supersonic and shock-cells are present in the jet. In commercial turbofan engines, at cruise, the secondary flow is often supersonic underexpanded, with the formation of annular shock-cells in the jet and consequent onset of shock-cell noise. This paper aims at describing the design process of the new facility FAST (Free jet AeroacouSTic laboratory at the von Karman Institute, aimed at the investigation of the shock-cell noise phenomenon on a dual stream jet. The rig consists of a coaxial open jet, with supersonic capability for both the primary and secondary flow. A coaxial silencer was designed to suppress the spurious noise coming from the feeding lines. Computational fluid dynamics (CFD simulations of the coaxial jet and acoustic simulations of the silencer have been carried out to support the design choices. Finally, the rig has been validated by performing experimental measurements on a supersonic single stream jet and comparing the results with the literature. Fine-scale PIV (Particle Image Velocimetry coupled with a microphone array in the far field have been used in this scope. Preliminary results of the dual stream jet are also shown.

  20. Design of a Large Single-Aperture Dipole Magnet for HL-LHC Upgrade

    CERN Document Server

    Qingjin, Xu; Iio, Masami; Ogitsu, Toru; Sasaki, Kenichi; Yamamoto, Akira; Todesco, Ezio

    2013-01-01

    An upgrade of the low-beta insertion system for the ATLAS and Compact Muon Solenoid experiments is proposed in the high luminosity Large Hadron Collider upgrade project. It includes final beam focusing quadrupoles, beam separation and recombination dipoles, and larger aperture matching section quadrupoles. KEK is in charge of the conceptual design of the large aperture separation dipole D1. The latest design parameters are a main field of ~ 5 T at 1.9 K with Nb-Ti superconducting technology, a coil aperture of 160 mm, and a cos-theta one-layer coil with Large Hadron Collider dipole cable. Because the new D1 is expected to be operated in a very high radiation environment, radiation resistance and a cooling scheme are being carefully considered. The collaring-yoke structure is adopted to provide the mechanical support for the single-layer Nb-Ti coil. We summarize the design study of this magnet, including i) the very large iron saturation effect on field quality due to the large aperture and limited size of the...

  1. Design principles of natural light-harvesting as revealed by single molecule spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Krüger, T.P.J., E-mail: tjaart.kruger@up.ac.za [Department of Physics, University of Pretoria, Private bag X20, Hatfield 0028 (South Africa); Grondelle, R. van [Department of Physics and Astronomy, VU University Amsterdam, De Boelelaan 1081, 1081 HV Amsterdam (Netherlands)

    2016-01-01

    Biology offers a boundless source of adaptation, innovation, and inspiration. A wide range of photosynthetic organisms exist that are capable of harvesting solar light in an exceptionally efficient way, using abundant and low-cost materials. These natural light-harvesting complexes consist of proteins that strongly bind a high density of chromophores to capture solar photons and rapidly transfer the excitation energy to the photochemical reaction centre. The amount of harvested light is also delicately tuned to the level of solar radiation to maintain a constant energy throughput at the reaction centre and avoid the accumulation of the products of charge separation. In this Review, recent developments in the understanding of light-harvesting by plants will be discussed, based on results obtained from single molecule spectroscopy studies. Three design principles of the main light-harvesting antenna of plants will be highlighted: (a) fine, photoactive control over the intrinsic protein disorder to efficiently use intrinsically available thermal energy dissipation mechanisms; (b) the design of the protein microenvironment of a low-energy chromophore dimer to control the amount of shade absorption; (c) the design of the exciton manifold to ensure efficient funneling of the harvested light to the terminal emitter cluster.

  2. Pharmacokinetics of a telmisartan/rosuvastatin fixed-dose combination: a single-dose, randomized, open-label, 2-period crossover study in healthy Korean subjects.

    Science.gov (United States)

    Chae, Dong Woo; Son, Mijeong; Kim, Yukyung; Son, Hankil; Jang, Seong Bok; Seo, Jeong Min; Nam, Su Youn; Park, Kyungsoo

    2015-10-01

    As hypertension and dyslipidemia are frequent comorbidities, antihypertensive drugs and lipid-lowering agents are often prescribed together for their treatment. Telmisartan and rosuvastatin are widely used together to treat hypertension and dyslipidemia. A combination formulation of these two drugs would improve patient compliance due to ease of dosing. The purpose of this study was to assess bioequivalence of single-dose administration of a newly-developed fixed-dose combination (FDC) tablet containing telmisartan/rosuvastatin 80/20 mg (test treatment) and coadministration of a telmisartan 80-mg tablet and a rosuvastatin 20-mg tablet (reference treatment) in healthy Korean male volunteers. This was a single-dose, randomized, open-label, 2-period crossover study enrolling healthy males aged 20 - 50 years with BMI between 18.5 and 25 kg/m2. Each subject received a single dose of the reference and test treatments with a 14-day washout period. Blood sampling was performed at prespecified intervals for up to 72 hours after dosing. Primary pharmacokinetic parameters were Cmax, AUClast, and AUC0-∞ of telmisartan, rosuvastatin, and N-desmethyl rosuvastatin. Bioequivalence was assessed by determining whether the 90% confidence intervals (CIs) of the geometric mean ratios (test treatment/reference treatment) of these parameters were within the standard range of 80% to 125%. Adverse events were monitored via regular interviews with the subjects and by physical examinations. 60 subjects were enrolled and 55 completed the study. The 90% CIs of the geometric mean ratios of Cmax, AUClast, and AUC00-∞ were 0.9262-1.1498, 0.9294-1.0313, and 0.9312-1.0320 for telmisartan, 0.9041-1.0428, 0.9262-1.0085, and 0.9307-1.0094 for rosuvastatin, and 0.8718-1.0022, 0.8901-0.9904, and 0.8872-0.9767 for N-desmethyl rosuvastatin, respectively. There was no statistical difference in the incidence of adverse events (AEs) (all of which were mild or moderate) between the reference and test

  3. Design and Development of a Model to Simulate 0-G Treadmill Running Using the European Space Agency's Subject Loading System

    Science.gov (United States)

    Caldwell, E. C.; Cowley, M. S.; Scott-Pandorf, M. M.

    2010-01-01

    Develop a model that simulates a human running in 0 G using the European Space Agency s (ESA) Subject Loading System (SLS). The model provides ground reaction forces (GRF) based on speed and pull-down forces (PDF). DESIGN The theoretical basis for the Running Model was based on a simple spring-mass model. The dynamic properties of the spring-mass model express theoretical vertical GRF (GRFv) and shear GRF in the posterior-anterior direction (GRFsh) during running gait. ADAMs VIEW software was used to build the model, which has a pelvis, thigh segment, shank segment, and a spring foot (see Figure 1).the model s movement simulates the joint kinematics of a human running at Earth gravity with the aim of generating GRF data. DEVELOPMENT & VERIFICATION ESA provided parabolic flight data of subjects running while using the SLS, for further characterization of the model s GRF. Peak GRF data were fit to a linear regression line dependent on PDF and speed. Interpolation and extrapolation of the regression equation provided a theoretical data matrix, which is used to drive the model s motion equations. Verification of the model was conducted by running the model at 4 different speeds, with each speed accounting for 3 different PDF. The model s GRF data fell within a 1-standard-deviation boundary derived from the empirical ESA data. CONCLUSION The Running Model aids in conducting various simulations (potential scenarios include a fatigued runner or a powerful runner generating high loads at a fast cadence) to determine limitations for the T2 vibration isolation system (VIS) aboard the International Space Station. This model can predict how running with the ESA SLS affects the T2 VIS and may be used for other exercise analyses in the future.

  4. Comparing Single Case Design Overlap-Based Effect Size Metrics from Studies Examining Speech Generating Device Interventions

    Science.gov (United States)

    Chen, Mo; Hyppa-Martin, Jolene K.; Reichle, Joe E.; Symons, Frank J.

    2016-01-01

    Meaningfully synthesizing single case experimental data from intervention studies comprised of individuals with low incidence conditions and generating effect size estimates remains challenging. Seven effect size metrics were compared for single case design (SCD) data focused on teaching speech generating device use to individuals with…

  5. Added value of integrated circuit detector in head CT: objective and subjective image quality in comparison to conventional detector design.

    Science.gov (United States)

    Korn, Andreas; Bender, Benjamin; Spira, Daniel; Schabel, Christoph; Bhadelia, Rafeeque; Claussen, Claus; Ernemann, Ulrike; Brodoefel, Harald

    2014-12-01

    A new computed tomography (CT) detector with integrated electric components and shorter conducting pathways has recently been introduced to decrease system inherent electronic noise. The purpose of this study was to assess the potential benefit of such integrated circuit detector (ICD) in head CT by comparing objective and subjective image quality in low-dose examinations with a conventional detector design. Using a conventional detector, reduced-dose noncontrast head CT (255 mAs; effective dose, 1.7 mSv) was performed in 25 consecutive patients. Following transition to ICD, 25 consecutive patients were scanned using identical imaging parameters. Images in both groups were reconstructed with iterative reconstruction (IR) and filtered back projection (FBP) and assessed in terms of quantitative and qualitative image quality. Acquisition of head CT using ICD increased signal-to-noise ratio of gray and white matter by 14% (10.0 ± 1.6 vs. 11.4 ± 2.5; P = .02) and 17% (8.2 ± 0.8 vs. 9.6 ± 1.5; P = .000). The associated improvement in contrast-to-noise ratio was 12% (2.0 ± 0.5 vs. 2.2 ± 0.6; P = .121). In addition, there was a 51% increase in objective image sharpness (582 ± 85 vs. 884.5 ± 191; change in HU/Pixel; P < .000). Compared to standard acquisitions, subjective grading of noise and overall image quality scores were significantly improved with ICD (2.1 ± 0.3 vs. 1.6 ± 0.3; P < .000; 2.0 ± 0.5 vs. 1.6 ± 0.3; P = .001). Moreover, streak artifacts in the posterior fossa were substantially reduced (2.3 ± 0.7 vs. 1.7 ± 0.5; P = .004). At the same radiation level, acquisition of head CT with ICD achieves superior objective and subjective image quality and provides potential for significant dose reduction. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.

  6. Design and Development of a Solar Thermal Collector with Single Axis Solar Tracking Mechanism

    Directory of Open Access Journals (Sweden)

    Theebhan Mogana

    2016-01-01

    Full Text Available The solar energy is a source of energy that is abundant in Malaysia and can be easily harvested. However, because of the rotation of the Earth about its axis, it is impossible to harvest the solar energy to the maximum capacity if the solar thermal collector is placed fix to a certain angle. In this research, a solar thermal dish with single axis solar tracking mechanism that will rotate the dish according to the position of the sun in the sky is designed and developed, so that more solar rays can be reflected to a focal point and solar thermal energy can be harvested from the focal point. Data were collected for different weather conditions and performance of the solar thermal collector with a solar tracker were studied and compared with stationary solar thermal collector.

  7. Thermal design of a modern, air-conditioned, single-floor, solar-powered desert house

    KAUST Repository

    Serag-Eldin, M. A.

    2011-12-01

    The paper presents a thermal analysis of a single-floor, solar-powered desert house. The house is air-conditioned and provides all modern comforts and facilities. Electrical power, which drives the entire energy system, is generated by roof-mounted photovoltaic modules. The modules are fixed on special cradles which fold at night to expose the roof to the night sky, thereby enhancing night-time cooling, which is substantial in the desert environment. A detailed dynamic heat transfer analysis is conducted for the building envelope, coupled with a solar radiation model. Application to a typical Middle-Eastern desert site reveals that indeed such a design is feasible with present-day technology; and should be even more attractive with future advances in technology. © 2011 Copyright Taylor and Francis Group, LLC.

  8. Precoding Design for Single-RF Massive MIMO Systems: A Large System Analysis

    KAUST Repository

    Sifaou, Houssem

    2016-08-26

    This work revisits a recently proposed precoding design for massive multiple-input multiple output (MIMO) systems that is based on the use of an instantaneous total power constraint. The main advantages of this technique lie in its suitability to the recently proposed single radio frequency (RF) MIMO transmitter coupled with a very-high power efficiency. Such features have been proven using simulations for uncorrelated channels. Based on tools from random matrix theory, we propose in this work to analyze the performance of this precoder for more involved channels accounting for spatial correlation. The obtained expressions are then optimized in order to maximize the signalto- interference-plus-noise ratio (SINR). Simulation results are provided in order to illustrate the performance of the optimized precoder in terms of peak-to-average power ratio (PAPR) and signal-to-interference-plus-noise ratio (SINR). © 2012 IEEE.

  9. Possibility designing half-wave and full-wave molecular rectifiers by using single benzene molecule

    Science.gov (United States)

    Abbas, Mohammed A.; Hanoon, Falah H.; Al-Badry, Lafy F.

    2018-02-01

    This work focused on possibility designing half-wave and full-wave molecular rectifiers by using single and two benzene rings, respectively. The benzene rings were threaded by a magnetic flux that changes over time. The quantum interference effect was considered as the basic idea in the rectification action, the para and meta configurations were investigated. All the calculations are performed by using steady-state theoretical model, which is based on the time-dependent Hamiltonian model. The electrical conductance and the electric current are considered as DC output signals of half-wave and full-wave molecular rectifiers. The finding in this work opens up the exciting potential to use these molecular rectifiers in molecular electronics.

  10. Designing Multifunctionality into Single Phase and Multiphase Metal-Oxide-Selective Propylene Ammoxidation Catalysts

    Directory of Open Access Journals (Sweden)

    James F. Brazdil

    2018-03-01

    Full Text Available Multifunctionality is the hallmark of most modern commercial heterogeneous catalyst systems in use today, including those used for the selective ammoxidation of propylene to acrylonitrile. It is the quintessential principle underlying commercial catalyst design efforts since petrochemical process development is invariably driven by the need to reduce manufacturing costs. This is in large part achieved through new and improved catalysts that increase selectivity and productivity. In addition, the future feedstocks for chemical processes will be invariably more refractory than those currently in use (e.g., replacing alkenes with alkanes or using CO2, thus requiring a disparate combination of chemical functions in order to effect multiple chemical transformations with the fewest separate process steps. This review summarizes the key chemical phenomena behind achieving the successful integration of multiple functions into a mixed-metal-oxide-selective ammoxidation catalyst. An experiential and functional catalyst design model is presented that consists of one or both of the following components: (1 a mixed-metal-oxide–solid solution where the individual metal components serve separate and necessary functions in the reaction mechanism through their atomic level interaction in the context of a single crystallographic structure; (2 the required elemental components and their catalytic function existing in separate phases, where these phases are able to interact for the purposes of electron and lattice oxygen transfer through the formation of a structurally coherent interface (i.e., epitaxy between the separate crystal structures. Examples are provided from the literature and explained in the context of this catalyst design model. The extension of the model concepts to the design of heterogeneous catalysts in general is also discussed.

  11. Optimizing Within-Subject Experimental Designs for jICA of Multi-Channel ERP and fMRI

    Science.gov (United States)

    Mangalathu-Arumana, Jain; Liebenthal, Einat; Beardsley, Scott A.

    2018-01-01

    Joint independent component analysis (jICA) can be applied within subject for fusion of multi-channel event-related potentials (ERP) and functional magnetic resonance imaging (fMRI), to measure brain function at high spatiotemporal resolution (Mangalathu-Arumana et al., 2012). However, the impact of experimental design choices on jICA performance has not been systematically studied. Here, the sensitivity of jICA for recovering neural sources in individual data was evaluated as a function of imaging SNR, number of independent representations of the ERP/fMRI data, relationship between instantiations of the joint ERP/fMRI activity (linear, non-linear, uncoupled), and type of sources (varying parametrically and non-parametrically across representations of the data), using computer simulations. Neural sources were simulated with spatiotemporal and noise attributes derived from experimental data. The best performance, maximizing both cross-modal data fusion and the separation of brain sources, occurred with a moderate number of representations of the ERP/fMRI data (10–30), as in a mixed block/event related experimental design. Importantly, the type of relationship between instantiations of the ERP/fMRI activity, whether linear, non-linear or uncoupled, did not in itself impact jICA performance, and was accurately recovered in the common profiles (i.e., mixing coefficients). Thus, jICA provides an unbiased way to characterize the relationship between ERP and fMRI activity across brain regions, in individual data, rendering it potentially useful for characterizing pathological conditions in which neurovascular coupling is adversely affected. PMID:29410611

  12. Diagnostic Value of Subjective Memory Complaints Assessed with a Single Item in Dominantly Inherited Alzheimer’s Disease: Results of the DIAN Study

    Directory of Open Access Journals (Sweden)

    Christoph Laske

    2015-01-01

    Full Text Available Objective. We examined the diagnostic value of subjective memory complaints (SMCs assessed with a single item in a large cross-sectional cohort consisting of families with autosomal dominant Alzheimer’s disease (ADAD participating in the Dominantly Inherited Alzheimer Network (DIAN. Methods. The baseline sample of 183 mutation carriers (MCs and 117 noncarriers (NCs was divided according to Clinical Dementia Rating (CDR scale into preclinical (CDR 0; MCs: n=107; NCs: n=109, early symptomatic (CDR 0.5; MCs: n=48; NCs: n=8, and dementia stage (CDR ≥ 1; MCs: n=28; NCs: n=0. These groups were subdivided by the presence or absence of SMCs. Results. At CDR 0, SMCs were present in 12.1% of MCs and 9.2% of NCs (P=0.6. At CDR 0.5, SMCs were present in 66.7% of MCs and 62.5% of NCs (P=1.0. At CDR ≥ 1, SMCs were present in 96.4% of MCs. SMCs in MCs were significantly associated with CDR, logical memory scores, Geriatric Depression Scale, education, and estimated years to onset. Conclusions. The present study shows that SMCs assessed by a single-item scale have no diagnostic value to identify preclinical ADAD in asymptomatic individuals. These results demonstrate the need of further improvement of SMC measures that should be examined in large clinical trials.

  13. Design of a Single-Cell Positioning Controller Using Electroosmotic Flow and Image Processing

    Directory of Open Access Journals (Sweden)

    Jhong-Yin Chen

    2013-05-01

    Full Text Available The objective of the current research was not only to provide a fast and automatic positioning platform for single cells, but also improved biomolecular manipulation techniques. In this study, an automatic platform for cell positioning using electroosmotic flow and image processing technology was designed. The platform was developed using a PCI image acquisition interface card for capturing images from a microscope and then transferring them to a computer using human-machine interface software. This software was designed by the Laboratory Virtual Instrument Engineering Workbench, a graphical language for finding cell positions and viewing the driving trace, and the fuzzy logic method for controlling the voltage or time of an electric field. After experiments on real human leukemic cells (U-937, the success of the cell positioning rate achieved by controlling the voltage factor reaches 100% within 5 s. A greater precision is obtained when controlling the time factor, whereby the success rate reaches 100% within 28 s. Advantages in both high speed and high precision are attained if these two voltage and time control methods are combined. The control speed with the combined method is about 5.18 times greater than that achieved by the time method, and the control precision with the combined method is more than five times greater than that achieved by the voltage method.

  14. THE DESIGN, FABRICATION AND PRELIMINARY TESTING OF AN INDIGENOUS SINGLE SCREW EXTRUDER

    Directory of Open Access Journals (Sweden)

    FOLASAYO T. FAYOSE

    2017-10-01

    Full Text Available Developing countries including Nigeria have become dumping grounds of unserviceable and broken down imported machineries because of poor adaptation. Detailed study and design of machines to suit local conditions will prevent poor adaptation of imported machines and high initial costs. In this study, a single screw starch extruder was designed, fabricated and tested using locally available materials. The extruder is the dry type and it has 27.12 kg/s capacity, a compression ratio of 4.5: 1 and is powered by a 5.5 kW electric motor. It consists of a hopper, feeding screw, extruder screw rotating in a barrel and variable die, all made of stainless steel. A unit of the machine costs N 470, 390.00.00 as at April 2015. When used to process cassava flour, a maximum temperature of 114°C was attained through viscous dissipation, up to an actual screw speed of 98.96 rpm (1.65 Hz and extruder efficiency of 64%. Barrel temperature varied directly with extrusion time in a polynomial trend while actual extruder screw speed and efficiency varied inversely with extrusion time and it is best fitted with a polynomial trend.

  15. Prototype design of singles processing unit for the small animal PET

    Science.gov (United States)

    Deng, P.; Zhao, L.; Lu, J.; Li, B.; Dong, R.; Liu, S.; An, Q.

    2018-05-01

    Position Emission Tomography (PET) is an advanced clinical diagnostic imaging technique for nuclear medicine. Small animal PET is increasingly used for studying the animal model of disease, new drugs and new therapies. A prototype of Singles Processing Unit (SPU) for a small animal PET system was designed to obtain the time, energy, and position information. The energy and position is actually calculated through high precison charge measurement, which is based on amplification, shaping, A/D conversion and area calculation in digital signal processing domian. Analysis and simulations were also conducted to optimize the key parameters in system design. Initial tests indicate that the charge and time precision is better than 3‰ FWHM and 350 ps FWHM respectively, while the position resolution is better than 3.5‰ FWHM. Commination tests of the SPU prototype with the PET detector indicate that the system time precision is better than 2.5 ns, while the flood map and energy spectra concored well with the expected.

  16. Design, operation, and safety of single-room interventional MRI suites: practical experience from two centers.

    Science.gov (United States)

    White, Mark J; Thornton, John S; Hawkes, David J; Hill, Derek L G; Kitchen, Neil; Mancini, Laura; McEvoy, Andrew W; Razavi, Reza; Wilson, Sally; Yousry, Tarek; Keevil, Stephen F

    2015-01-01

    The design and operation of a facility in which a magnetic resonance imaging (MRI) scanner is incorporated into a room used for surgical or endovascular cardiac interventions presents several challenges. MR safety must be maintained in the presence of a much wider variety of equipment than is found in a diagnostic unit, and of staff unfamiliar with the MRI environment, without compromising the safety and practicality of the interventional procedure. Both the MR-guided cardiac interventional unit at Kings College London and the intraoperative imaging suite at the National Hospital for Neurology and Neurosurgery are single-room interventional facilities incorporating 1.5 T cylindrical-bore MRI scanners. The two units employ similar strategies to maintain MR safety, both in original design and day-to-day operational workflows, and between them over a decade of incident-free practice has been accumulated. This article outlines these strategies, highlighting both similarities and differences between the units, as well as some lessons learned and resulting procedural changes made in both units since installation. © 2014 Wiley Periodicals, Inc.

  17. Design and implementation of a personal mobility of single spherical drive

    International Nuclear Information System (INIS)

    Hoshino, Tasuku; Yazawa, Miki; Naganuma, Ryota; Takada, Kotaro

    2016-01-01

    This paper deals with a personal electric vehicle driven by a single spherical wheel. Using an appropriate feedback control, this driving strategy realizes dynamic stability in all directions and the vehicle can always be kept upright on the road surface of variety of slopes. It also enables immediate mobility to all directions, unlike personal vehicles of two- wheel type. The spherical wheel is driven by omnidirectional wheels as usual; however, since the number and location of wheels have huge effect on the driving performance, the authors firstly analyze kinematics of omnidirectional wheels and sphere and derive new configuration to achieve maximum power. Based on the kinematic analysis, the equation of motion of the vehicle is derived via Lagrangian formulation. The full dynamic model including kinematic constraints is then derived. Using the full model, a stabilizing controller for driving is designed based on partial feedback linearization technique. The vehicle is constructed and tested with a human driver. The proposed configuration of omnidirectional wheels, the controller design model and the control scheme are examined in practice. Results of the experiments, including going over uphill road and uneven ground, show much better driving performance than authors’ previous prototype of the similar. (paper)

  18. Design of a high-pressure single pulse shock tube for chemical kinetic investigations

    International Nuclear Information System (INIS)

    Tranter, R. S.; Brezinsky, K.; Fulle, D.

    2001-01-01

    A single pulse shock tube has been designed and constructed in order to achieve extremely high pressures and temperatures to facilitate gas-phase chemical kinetic experiments. Postshock pressures of greater than 1000 atmospheres have been obtained. Temperatures greater than 1400 K have been achieved and, in principle, temperatures greater than 2000 K are easily attainable. These high temperatures and pressures permit the investigation of hydrocarbon species pyrolysis and oxidation reactions. Since these reactions occur on the time scale of 0.5--2 ms the shock tube has been constructed with an adjustable length driven section that permits variation of reaction viewing times. For any given reaction viewing time, samples can be withdrawn through a specially constructed automated sampling apparatus for subsequent species analysis with gas chromatography and mass spectrometry. The details of the design and construction that have permitted the successful generation of very high-pressure shocks in this unique apparatus are described. Additional information is provided concerning the diaphragms used in the high-pressure shock tube

  19. Seismic Design of a Single Bored Tunnel: Longitudinal Deformations and Seismic Joints

    Science.gov (United States)

    Oh, J.; Moon, T.

    2018-03-01

    The large diameter bored tunnel passing through rock and alluvial deposits subjected to seismic loading is analyzed for estimating longitudinal deformations and member forces on the segmental tunnel liners. The project site has challenges including high hydrostatic pressure, variable ground profile and high seismic loading. To ensure the safety of segmental tunnel liner from the seismic demands, the performance-based two-level design earthquake approach, Functional Evaluation Earthquake and Safety Evaluation Earthquake, has been adopted. The longitudinal tunnel and ground response seismic analyses are performed using a three-dimensional quasi-static linear elastic and nonlinear elastic discrete beam-spring elements to represent segmental liner and ground spring, respectively. Three components (longitudinal, transverse and vertical) of free-field ground displacement-time histories evaluated from site response analyses considering wave passage effects have been applied at the end support of the strain-compatible ground springs. The result of the longitudinal seismic analyses suggests that seismic joint for the mitigation measure requiring the design deflection capacity of 5-7.5 cm is to be furnished at the transition zone between hard and soft ground condition where the maximum member forces on the segmental liner (i.e., axial, shear forces and bending moments) are induced. The paper illustrates how detailed numerical analyses can be practically applied to evaluate the axial and curvature deformations along the tunnel alignment under difficult ground conditions and to provide the seismic joints at proper locations to effectively reduce the seismic demands below the allowable levels.

  20. Proposal of a Self-baking Single-wall Design for the VI Section of the ATLAS Beam Pipe

    CERN Document Server

    Marco Olcese, MO

    2002-01-01

    A single-wall design for the VI section of the ATLAS beam vacuum chamber is presented. This design would allow for a major cost saving with respect to the current double-wall baseline. All the thermal implications and impact on the B-layer mudules are discussed.

  1. Design of Slow and Fast Light Photonic Crystal Waveguides for Single-photon Emission Using a Bloch Mode Expansion Technique

    DEFF Research Database (Denmark)

    de Lasson, Jakob Rosenkrantz; Rigal, B.; Kapon, E.

    We design slow and fast light photonic crystal waveguides for single-photon emission using a Bloch mode expansion and scattering matrix technique. We propose slow light designs that increase the group index-waveguide mode volume ratio for larger Purcell enhancement, and address efficient slow-to-...

  2. Esophageal transit and in vivo disintegration of branded risedronate sodium tablets and two generic formulations of alendronic acid tablets: a single-center, single-blind, six-period crossover study in healthy female subjects.

    Science.gov (United States)

    Perkins, Alan C; Blackshaw, P Elaine; Hay, Peter D; Lawes, Simon C; Atherton, Clare T; Dansereau, Richard J; Wagner, Leigh K; Schnell, Dan J; Spiller, Robin C

    2008-05-01

    Delayed esophageal transit or disintegration of oral bisphosphonate tablets before they enter the stomach may be of concern with respect to iatrogenic complications among patients receiving longterm treatment. Different formulations of generic bisphosphonate tablets meeting regulatory requirements may have substantial differences in pharmaceutical attributes from the branded product that may result in different characteristics during esophageal transit. The primary objective of this study was to evaluate and compare esophageal transit times and in vivo disintegration of 3 bisphosphonate formulations, one branded and the others generic, that are commercially available in Canada and the United Kingdom. This was a single-center, randomized, singleblind, 6-period crossover study in healthy postmenopausal women aged >50 years. Each subject received a single oral dose of a branded risedronate sodium 35-mg tablet and 2 generic formulations of alendronic acid 70-mg tablets (Novopharm Limited, Toronto, Canada, and Teva UK Limited, Morley, United Kingdom) in both the erect and semisupine (45 degrees ) positions. Although the products are labeled to be taken in the erect position, the semisupine position was included to simulate dosing in bedridden patients. Subjects took tablets with 30 mL of water in the morning after an overnight fast. The tablets were radiolabeled with technetium-99m ion-exchange resins to enable visualization and measurement of esophageal transit time and disintegration using a gamma camera. Dynamic scintigraphic images were obtained for a total of 10 minutes: 2 images per second for the first 30 seconds and 1 image every 15 seconds for 9.5 minutes. This was a mechanistic study and tolerability was not assessed. The study was conducted in 20 healthy white female subjects with a mean age of 62 years (range, 51-77 years). The effect of body position was statistically significant (P = 0.043), with the estimated hazard ratio (HR) of 0.74 indicating longer

  3. A Phase 1, Single-center, Double-blind, Placebo-controlled Study in Healthy Subjects to Assess the Safety, Tolerability, Clinical Effects, and Pharmacokinetics-Pharmacodynamics of Intravenous Cyclopropyl-methoxycarbonylmetomidate (ABP-700) after a Single Ascending Bolus Dose.

    Science.gov (United States)

    Struys, Michel M R F; Valk, Beatrijs I; Eleveld, Douglas J; Absalom, Anthony R; Meyer, Peter; Meier, Sascha; den Daas, Izaak; Chou, Thomas; van Amsterdam, Kai; Campagna, Jason A; Sweeney, Steven P

    2017-07-01

    Cyclopropyl-methoxycarbonylmetomidate (ABP-700) is a new "soft" etomidate analog. The primary objectives of this first-in-human study were to describe the safety and efficacy of ABP-700 and to determine its maximum tolerated dose. Secondary objectives were to characterize the pharmacokinetics of ABP-700 and its primary metabolite (cyclopropyl-methoxycarbonyl acid), to assess the clinical effects of ABP-700, and to investigate the dose-response and pharmacokinetic/pharmacodynamic relationships. Sixty subjects were divided into 10 cohorts and received an increasing, single bolus of either ABP-700 or placebo. Safety was assessed by clinical laboratory evaluations, infusion-site reactions, continuous monitoring of vital signs, physical examination, adverse event monitoring, and adrenocorticotropic hormone stimulation testing. Clinical effects were assessed with modified observer's assessment of alertness/sedation and Bispectral Index monitoring. Pharmacokinetic parameters were calculated. Stopping criteria were met at 1.00 mg/kg dose. No serious adverse events were reported. Adverse events were dose-dependent and comprised involuntary muscle movement, tachycardia, and ventilatory effects. Adrenocorticotropic hormone stimulation evoked a physiologic cortisol response in all subjects, no different from placebo. Pharmacokinetics were dose-proportional. A three-compartment pharmacokinetic model described the data well. A rapid onset of anesthesia/sedation after bolus administration and also a rapid recovery were observed. A quantitative concentration-effect relationship was described for the modified observer's assessment of alertness/sedation and Bispectral Index. This first-in-human study of ABP-700 shows that ABP-700 was safe and well tolerated after single-bolus injections up to 1.00 mg/kg. Bolus doses of 0.25 and 0.35 mg/kg were found to provide the most beneficial clinical effect versus side-effect profile.

  4. Differential effects of dietary protein sources on postprandial low-grade inflammation after a single high fat meal in obese non-diabetic subjects

    Directory of Open Access Journals (Sweden)

    Herzig Karl-Heinz

    2011-10-01

    Full Text Available Abstract Background Obesity is a state of chronic low-grade inflammation. Chronic low-grade inflammation is associated with the pathophysiology of both type-2 diabetes and atherosclerosis. Prevention or reduction of chronic low-grade inflammation may be advantageous in relation to obesity related co-morbidity. In this study we investigated the acute effect of dietary protein sources on postprandial low-grade inflammatory markers after a high-fat meal in obese non-diabetic subjects. Methods We conducted a randomized, acute clinical intervention study in a crossover design. We supplemented a fat rich mixed meal with one of four dietary proteins - cod protein, whey isolate, gluten or casein. 11 obese non-diabetic subjects (age: 40-68, BMI: 30.3-42.0 kg/m2 participated and blood samples were drawn in the 4 h postprandial period. Adiponectin was estimated by ELISA methods and cytokines were analyzed by multiplex assay. Results MCP-1 and CCL5/RANTES displayed significant postprandial dynamics. CCL5/RANTES initially increased after all meals, but overall CCL5/RANTES incremental area under the curve (iAUC was significantly lower after the whey meal compared with the cod and casein meals (P = 0.0053. MCP-1 was initially suppressed after all protein meals. However, the iAUC was significantly higher after whey meal compared to the cod and gluten meals (P = 0.04. Conclusion We have demonstrated acute differential effects on postprandial low grade inflammation of four dietary proteins in obese non-diabetic subjects. CCL5/RANTES initially increased after all meals but the smallest overall postprandial increase was observed after the whey meal. MCP-1 was initially suppressed after all 4 protein meals and the whey meal caused the smallest overall postprandial suppression. Trial Registration ClinicalTrials.gov ID: NCT00863564

  5. Optimized design and structural mechanics of a single-piece composite helicopter driveshaft

    Science.gov (United States)

    Henry, Todd C.

    In rotorcraft driveline design, single-piece composite driveshafts have much potential for reducing driveline mass and complexity over multi-segmented metallic driveshafts. The singlepiece shaft concept is enabled by the relatively high fatigue strain capacity of fiber reinforced polymer composites over metals. Challenges for single-piece driveshaft design lie in addressing the self-heating behavior of the composite due to the material damping, as well as, whirling stability, torsional buckling stability, and composite strength. Increased composite temperature due to self-heating reduces the composite strength and is accounted for in this research. The laminate longitudinal stiffness ( Ex) and strength (Fx) are known to be heavily degraded by fiber undulation, however, both are not well understood in compression. The whirling stability (a function of longitudinal stiffness) and the composite strength are strongly influential in driveshaft optimization, and thus are investigated further through the testing of flat and filament wound composite specimens. The design of single-piece composite driveshafts, however, needs to consider many failure criteria, including hysteresis-induced overheating, whirl stability, torsional buckling stability, and material failure by overstress. The present investigation uses multi-objective optimization to investigate the design space which visually highlights design trades. Design variables included stacking sequence, number of laminas, and number of hanger bearings. The design goals were to minimize weight and maximize the lowest factor of safety by adaptively generating solutions to the multi-objective problem. Several design spaces were investigated by examining the effect of misalignment, ambient temperature, and constant power transmission on the optimized solution. Several materials of interest were modeled using experimentally determined elastic properties and novel temperature-dependent composite strength. Compared to the

  6. Safety and Tolerability of Theta Burst Stimulation versus Single and Paired Pulse Transcranial Magnetic Stimulation: A Comparative Study of 165 Pediatric Subjects

    Directory of Open Access Journals (Sweden)

    Yaejee H Hong

    2015-02-01

    Full Text Available Background: Although single- and paired-pulse (sp/pp transcranial magnetic stimulation (TMS studies are considered minimal risk in adults and children, the safety profile for theta-burst TMS (TBS is unknown.Objective: In this comparative analysis, we explored the rate, severity, and specific symptoms of TMS-related adverse effects (AEs between sp/ppTMS and TBS in subjects between ages 6 and 18 years.Method: Data from 165 participants from 2009-2014 were analyzed. Assessment of AEs was performed based on baseline and post-TMS administration of a symptom-based questionnaire that rated AEs on a 5-level ordinal scale (minimal, mild, moderate, marked, severe. AE rates and severity were compared using Chi Square or Fisher’s Exact Test depending on data characteristics.Result: Overall, no seizures or severe-rated AEs were reported by 165 pediatric participants. The rate of AE in all TBS sessions was 10.5% (n=76, 95% CI: 4.7 - 19.7%, whereas the rate of AE in all sp/ppTMS sessions was 12.4% (n=89, 95% CI: 6.3 - 21.0%. There was no statistical difference in AE rates between TBS and sp/ppTMS (p=0.71. In all sp/ppTMS and TBS sessions, 20 subjects reported a total of 35 AEs, among these 31 (~88.6% were rated as minimal or mild. There was no difference in the severity of AE between TBS and sp/ppTMS (p=1.0. Only one of 76 TBS participants reported an AE rated as more than minimal/mild.Conclusion: Our comparative analysis showed that TBS appears to be as safe as sp/ppTMS in terms of AE rate and severity. This report supports further investigation of TBS in children.

  7. Single-subject-based whole-brain MEG slow-wave imaging approach for detecting abnormality in patients with mild traumatic brain injury

    Directory of Open Access Journals (Sweden)

    Ming-Xiong Huang

    2014-01-01

    Full Text Available Traumatic brain injury (TBI is a leading cause of sustained impairment in military and civilian populations. However, mild TBI (mTBI can be difficult to detect using conventional MRI or CT. Injured brain tissues in mTBI patients generate abnormal slow-waves (1–4 Hz that can be measured and localized by resting-state magnetoencephalography (MEG. In this study, we develop a voxel-based whole-brain MEG slow-wave imaging approach for detecting abnormality in patients with mTBI on a single-subject basis. A normative database of resting-state MEG source magnitude images (1–4 Hz from 79 healthy control subjects was established for all brain voxels. The high-resolution MEG source magnitude images were obtained by our recent Fast-VESTAL method. In 84 mTBI patients with persistent post-concussive symptoms (36 from blasts, and 48 from non-blast causes, our method detected abnormalities at the positive detection rates of 84.5%, 86.1%, and 83.3% for the combined (blast-induced plus with non-blast causes, blast, and non-blast mTBI groups, respectively. We found that prefrontal, posterior parietal, inferior temporal, hippocampus, and cerebella areas were particularly vulnerable to head trauma. The result also showed that MEG slow-wave generation in prefrontal areas positively correlated with personality change, trouble concentrating, affective lability, and depression symptoms. Discussion is provided regarding the neuronal mechanisms of MEG slow-wave generation due to deafferentation caused by axonal injury and/or blockages/limitations of cholinergic transmission in TBI. This study provides an effective way for using MEG slow-wave source imaging to localize affected areas and supports MEG as a tool for assisting the diagnosis of mTBI.

  8. The Effect of Isomaltulose Together with Green Tea on Glycemic Response and Antioxidant Capacity: A Single-Blind, Crossover Study in Healthy Subjects.

    Science.gov (United States)

    Suraphad, Passakorn; Suklaew, Phim On; Ngamukote, Sathaporn; Adisakwattana, Sirichai; Mäkynen, Kittana

    2017-05-06

    Isomaltulose, a naturally-occurring isomer of sucrose, is commonly used as an alternative sweetener in foods and beverages. The goal of this study was to determine the effect of isomaltulose together with green tea on postprandial plasma glucose and insulin concentration, as well as antioxidant capacity in healthy subjects. In a randomized, single-blind, crossover study, 15 healthy subjects (eight women and seven men; ages 23.5 ± 0.7 years; with body mass index of 22.6 ± 0.4 kg/m²) consumed five beverages: (1) 50 g sucrose in 400 mL water; (2) 50 g isomaltulose in 400 mL of water; (3) 400 mL of green tea; (4) 50 g sucrose in 400 mL of green tea; and (5) 50 g isomaltulose in 400 mL of green tea. Incremental area under postprandial plasma glucose, insulin, ferric reducing ability of plasma (FRAP) and malondialdehyde (MDA) concentration were determined during 120 min of administration. Following the consumption of isomaltulose, the incremental 2-h area under the curve (AUC 0-2 h ) indicated a higher reduction of postprandial glucose (43.4%) and insulin concentration (42.0%) than the consumption of sucrose. The addition of green tea to isomaltulose produced a greater suppression of postprandial plasma glucose (20.9%) and insulin concentration (37.7%). In accordance with antioxidant capacity, consumption of sucrose (40.0%) and isomaltulose (28.7%) caused the reduction of green tea-induced postprandial increases in FRAP. A reduction in postprandial MDA after drinking green tea was attenuated when consumed with sucrose (34.7%) and isomaltulose (17.2%). In conclusion, green tea could enhance the reduction of postprandial glucose and insulin concentration when consumed with isomaltulose. In comparison with sucrose, isomaltulose demonstrated less alteration of plasma antioxidant capacity after being consumed with green tea.

  9. Effects of formulation on the bioavailability of lutein and zeaxanthin: a randomized, double-blind, cross-over, comparative, single-dose study in healthy subjects.

    Science.gov (United States)

    Evans, Malkanthi; Beck, Mareike; Elliott, James; Etheve, Stephane; Roberts, Richard; Schalch, Wolfgang

    2013-06-01

    Lutein and zeaxanthin are macular pigments with a protective function in the retina. These xanthophylls must be obtained from the diet or added to foods or supplements via easy-to-use, stable formulations. The technique employed to produce these formulations may affect the bioavailability of the xanthophylls. Forty-eight healthy volunteers were randomized into this double-blind, cross-over study investigating the plasma kinetics of lutein provided as two different beadlet formulations. Subjects (n = 48) received a single dose of 20 mg of lutein as either a starch-matrix ("SMB", FloraGLO® Lutein 5 %) or as a cross-linked alginate-matrix beadlet ("AMB", Lyc-O-Lutein 20 %) formulation. Plasma concentrations of lutein and zeaxanthin were measured at 0, 1, 3, 6, 9, 12, 14, 24, 26, 28, 32, 36, 48, 72, 168, and 672 h. The mean plasma AUC(0-72h), AUC(0-672h), and C(max) for total lutein and zeaxanthin and their all-E-isomers were significantly increased (p < 0.001) from pre-dose concentrations in response to SMB and AMB. There was no difference in lutein T max between the two test articles. However, by 14 h post-dose, total plasma lutein increased by 7 % with AMB and by 126 % with SMB. Total lutein AUC(0-72h) and AUC(0-672h) were 1.8-fold and 1.3-fold higher, respectively, for SMB compared to AMB. Both formulations were well tolerated by subjects in this study. These findings confirm that the bioavailability of lutein and zeaxanthin critically depends on the formulation used and document a superiority of the starch-based over the alginate-based product in this study.

  10. Imagery Rescripting for Body Dysmorphic Disorder: A Multiple-Baseline Single-Case Experimental Design.

    Science.gov (United States)

    Willson, Rob; Veale, David; Freeston, Mark

    2016-03-01

    Individuals with body dysmorphic disorder (BDD) often experience negative distorted images of their appearance, and research suggests these may be linked to memories of adverse events such as bullying or teasing. This study evaluates imagery rescripting (ImR) as an intervention for BDD. In this article, we present a multiple-baseline single-case experimental design testing imagery rescripting as a brief, stand-alone intervention, with six individuals with BDD that related to aversive memories. The impact of the intervention was assessed by self-reported daily measures of symptom severity (preoccupation with appearance, appearance-related checking behaviors, appearance-related distress, and strength of belief that their main problem is their appearance) and standardized clinician ratings of BDD severity (Yale-Brown Obsessive Compulsive Scale modified for BDD). Four out of six of the participants responded positively to the intervention, with clinically meaningful improvement in symptomatology. Overall response was rapid; improvements began within the first week post-ImR intervention. From a small sample it is cautiously concluded that imagery rescripting may show promise as a module in cognitive-behavioral therapy for BDD, and is worthy of further investigation. Copyright © 2015. Published by Elsevier Ltd.

  11. An introduction to modeling longitudinal data with generalized additive models: applications to single-case designs.

    Science.gov (United States)

    Sullivan, Kristynn J; Shadish, William R; Steiner, Peter M

    2015-03-01

    Single-case designs (SCDs) are short time series that assess intervention effects by measuring units repeatedly over time in both the presence and absence of treatment. This article introduces a statistical technique for analyzing SCD data that has not been much used in psychological and educational research: generalized additive models (GAMs). In parametric regression, the researcher must choose a functional form to impose on the data, for example, that trend over time is linear. GAMs reverse this process by letting the data inform the choice of functional form. In this article we review the problem that trend poses in SCDs, discuss how current SCD analytic methods approach trend, describe GAMs as a possible solution, suggest a GAM model testing procedure for examining the presence of trend in SCDs, present a small simulation to show the statistical properties of GAMs, and illustrate the procedure on 3 examples of different lengths. Results suggest that GAMs may be very useful both as a form of sensitivity analysis for checking the plausibility of assumptions about trend and as a primary data analysis strategy for testing treatment effects. We conclude with a discussion of some problems with GAMs and some future directions for research on the application of GAMs to SCDs. (c) 2015 APA, all rights reserved).

  12. Design of a serotonin 4 receptor radiotracer with decreased lipophilicity for single photon emission computed tomography.

    Science.gov (United States)

    Fresneau, Nathalie; Dumas, Noé; Tournier, Benjamin B; Fossey, Christine; Ballandonne, Céline; Lesnard, Aurélien; Millet, Philippe; Charnay, Yves; Cailly, Thomas; Bouillon, Jean-Philippe; Fabis, Frédéric

    2015-04-13

    With the aim to develop a suitable radiotracer for the brain imaging of the serotonin 4 receptor subtype (5-HT4R) using single photon emission computed tomography (SPECT), we synthesized and evaluated a library of di- and triazaphenanthridines with lipophilicity values which were in the range expected to favour brain penetration, and which demonstrated specific binding to the target of interest. Adding additional nitrogen atoms to previously described phenanthridine ligands exhibiting a high unspecific binding, we were able to design a radioiodinated compound [(125)I]14. This compound exhibited a binding affinity value of 0.094 nM toward human 5-HT4R and a high selectivity over other serotonin receptor subtypes (5-HTR). In vivo SPECT imaging studies and competition experiments demonstrated that the decreased lipophilicity (in comparison with our previously reported compounds 4 and 5) allowed a more specific labelling of the 5-HT4R brain-containing regions. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  13. Single stage batch adsorber design for efficient Eosin yellow removal by polyaniline coated ligno-cellulose.

    Science.gov (United States)

    Debnath, Sushanta; Ballav, Niladri; Maity, Arjun; Pillay, Kriveshini

    2015-01-01

    Polyaniline-coated lignin-based adsorbent (PLC) was synthesized and used for uptake of reactive dye eosin yellow (EY) from aqueous solution. The adsorption capability of the adsorbent was found to be more effective than the unmodified adsorbent (LC). In particular, the adsorption capability of the PLC was effective over a wider pH range. This could be owing to its higher point of zero charge, which is more favorable for the uptake of the anionic dye. Adsorption isotherm models suggested a monolayer adsorption was predominant. The mean free energy of adsorption (E(DR)) was found to have values between 8 and 16 kJ mol(-1) which suggests that an electrostatic mechanism of adsorption predominated over other underlying mechanisms. The adsorption process was also found to be spontaneous, with increasing negative free energy values observed at higher temperatures. Chemisorption process was supported by the changes in enthalpy above 40 kJ mol(-1) and by the results of desorption studies. This new adsorbent was also reusable and regenerable over four successive adsorption-desorption cycles. The single stage adsorber design revealed that PLC can be applicable as an effective biosorbent for the treatment of industrial effluents containing EY dye. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Compact Single-Layer Traveling-Wave Antenna DesignUsing Metamaterial Transmission Lines

    Science.gov (United States)

    Alibakhshikenari, Mohammad; Virdee, Bal Singh; Limiti, Ernesto

    2017-12-01

    This paper presents a single-layer traveling-wave antenna (TWA) that is based on composite right/left-handed (CRLH)-metamaterial (MTM) transmission line (TL) structure, which is implemented by using a combination of interdigital capacitors and dual-spiral inductive slots. By embedding dual-spiral inductive slots inside the CRLH MTM-TL results in a compact TWA. Dimensions of the proposed CRLH MTM-TL TWA is 21.5 × 30.0 mm2 or 0.372λ0 × 0.520λ0 at 5.2 GHz (center frequency). The fabricated TWA operates over 1.8-8.6 GHz with a fractional bandwidth greater than 120%, and it exhibits a peak gain and radiation efficiency of 4.2 dBi and 81%, respectively, at 5 GHz. By avoiding the use of lumped components, via-holes or defected ground structures, the proposed TWA design is economic for mass production as well as easy to integrate with wireless communication systems.

  15. Rational design of single-ion magnets and spin qubits based on mononuclear lanthanoid complexes.

    Science.gov (United States)

    Baldoví, José J; Cardona-Serra, Salvador; Clemente-Juan, Juan M; Coronado, Eugenio; Gaita-Ariño, Alejandro; Palii, Andrew

    2012-11-19

    Here we develop a general approach to calculating the energy spectrum and the wave functions of the low-lying magnetic levels of a lanthanoid ion submitted to the crystal field created by the surrounding ligands. This model allows us to propose general criteria for the rational design of new mononuclear lanthanoid complexes behaving as single-molecule magnets (SMMs) or acting as robust spin qubits. Three typical environments exhibited by these metal complexes are considered, namely, (a) square antiprism, (b) triangular dodecahedron, and (c) trigonal prism. The developed model is used to explain the properties of some representative examples showing these geometries. Key questions in this area, such as the chemical tailoring of the superparamagnetic energy barrier, tunneling gap, or spin relaxation time, are discussed. Finally, in order to take into account delocalization and/or covalent effects of the ligands, this point-charge model is complemented with ab initio calculations, which provide accurate information on the charge distribution around the metal, allowing for an explanation of the SMM behavior displayed by some sandwich-type organometallic compounds.

  16. Design principles for single standing nanowire solar cells: going beyond the planar efficiency limits.

    Science.gov (United States)

    Zeng, Yang; Ye, Qinghao; Shen, Wenzhong

    2014-05-09

    Semiconductor nanowires (NWs) have long been used in photovoltaic applications but restricted to approaching the fundamental efficiency limits of the planar devices with less material. However, recent researches on standing NWs have started to reveal their potential of surpassing these limits when their unique optical property is utilized in novel manners. Here, we present a theoretical guideline for maximizing the conversion efficiency of a single standing NW cell based on a detailed study of its optical absorption mechanism. Under normal incidence, a standing NW behaves as a dielectric resonator antenna, and its optical cross-section shows its maximum when the lowest hybrid mode (HE11δ) is excited along with the presence of a back-reflector. The promotion of the cell efficiency beyond the planar limits is attributed to two effects: the built-in concentration caused by the enlarged optical cross-section, and the shifting of the absorption front resulted from the excited mode profile. By choosing an optimal NW radius to support the HE11δ mode within the main absorption spectrum, we demonstrate a relative conversion-efficiency enhancement of 33% above the planar cell limit on the exemplary a-Si solar cells. This work has provided a new basis for designing and analyzing standing NW based solar cells.

  17. Treatment of paranoid personality disorder with cognitive analytic therapy: a mixed methods single case experimental design.

    Science.gov (United States)

    Kellett, Stephen; Hardy, Gillian

    2014-01-01

    Paranoid personality disorder (PPD) presents as chronic and widespread interpersonal distrust, whereby the actions of others are interpreted as malevolent and malicious. This research details the assessment, formulation and treatment of a case of PPD within a 24-session contract of cognitive analytic therapy (CAT). The outcome methodology was an A/B with extended follow-up single case experimental design (SCED). The SCED was supplemented with qualitative patient interviewing via the Change Interview regarding their experience of CAT, whether change had taken place and detailing of any identified change mechanisms. Quantitative results show that five out of the six daily rated paranoia target complaint measures were extinguished during the treatment phase. Qualitatively, the patient attributed change to the therapy conducted. The results suggest that CAT was an effective intervention in this case of PPD and are discussed in terms of identified methodological shortcomings, treatment implications and the potential for generating a convincing evidence base for the psychotherapy of PPD. Narrative reformulation using a CAT model offers a key opportunity for the patient to achieve a new understanding of their paranoia. Psychotherapy for PPD requires a cognitive component, within a boundaried and relational therapy, that is able to reflect on paranoid enactments and ruptures within the therapeutic relationship.There is a large role for clinician-researchers in developing a PPD outcome evidence base. Copyright © 2013 John Wiley & Sons, Ltd.

  18. Catalysis by Design: Well-Defined Single-Site Heterogeneous Catalysts

    KAUST Repository

    Pelletier, Jeremie

    2016-03-09

    ConspectusHeterogeneous catalysis, a field important industrially and scientifically, is increasingly seeking and refining strategies to render itself more predictable. The main issue is due to the nature and the population of catalytically active sites. Their number is generally low to very low, their "acid strengths" or " redox properties" are not homogeneous, and the material may display related yet inactive sites on the same material. In many heterogeneous catalysts, the discovery of a structure-activity reationship is at best challenging. One possible solution is to generate single-site catalysts in which most, if not all, of the sites are structurally identical. Within this context and using the right tools, the catalyst structure can be designed and well-defined, to reach a molecular understanding. It is then feasible to understand the structure-activity relationship and to develop predictable heterogeneous catalysis. Single-site well-defined heterogeneous catalysts can be prepared using concepts and tools of surface organometallic chemistry (SOMC). This approach operates by reacting organometallic compounds with surfaces of highly divided oxides (or of metal nanoparticles). This strategy has a solid track record to reveal structure-activity relationship to the extent that it is becoming now quite predictable. Almost all elements of the periodical table have been grafted on surfaces of oxides (from simple oxides such as silica or alumina to more sophisticated materials regarding composition or porosity).Considering catalytic hydrocarbon transformations, heterogeneous catalysis outcome may now be predicted based on existing mechanistic proposals and the rules of molecular chemistry (organometallic, organic) associated with some concepts of surface sciences. A thorough characterization of the grafted metal centers must be carried out using tools spanning from molecular organometallic or surface chemistry. By selection of the metal, its ligand set, and the

  19. Design and efficacy of a single-use bioreactor for heart valve tissue engineering.

    Science.gov (United States)

    Converse, Gabriel L; Buse, Eric E; Neill, Kari R; McFall, Christopher R; Lewis, Holley N; VeDepo, Mitchell C; Quinn, Rachael W; Hopkins, Richard A

    2017-02-01

    Heart valve tissue engineering offers the promise of improved treatments for congenital heart disorders; however, widespread clinical availability of a tissue engineered heart valve (TEHV) has been hindered by scientific and regulatory concerns, including the lack of a disposable, bioreactor system for nondestructive valve seeding and mechanical conditioning. Here we report the design for manufacture and the production of full scale, functional prototypes of such a system. To evaluate the efficacy of this bioreactor as a tool for seeding, ovine aortic valves were decellularized and subjected to seeding with human mesenchymal stem cells (hMSC). The effects of pulsatile conditioning using cyclic waveforms tuned to various negative and positive chamber pressures were evaluated, with respect to the seeding of cells on the decellularized leaflet and the infiltration of seeded cells into the interstitium of the leaflet. Infiltration of hMSCs into the aortic valve leaflet was observed following 72 h of conditioning under negative chamber pressure. Additional conditioning under positive pressure improved cellular infiltration, while retaining gene expression within the MSC-valve interstitial cell phenotype lineage. This protocol resulted in a subsurface pilot population of cells, not full tissue recellularization. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 249-259, 2017. © 2015 Wiley Periodicals, Inc.

  20. Optical design and studies of a tiled single grating pulse compressor for enhanced parametric space and compensation of tiling errors

    Science.gov (United States)

    Daiya, D.; Patidar, R. K.; Sharma, J.; Joshi, A. S.; Naik, P. A.; Gupta, P. D.

    2017-04-01

    A new optical design of tiled single grating pulse compressor has been proposed, set-up and studied. The parametric space, i.e. the laser beam diameters that can be accommodated in the pulse compressor for the given range of compression lengths, has been calculated and shown to have up to two fold enhancement in comparison to our earlier proposed optical designs. The new optical design of the tiled single grating pulse compressor has an additional advantage of self compensation of various tiling errors like longitudinal and lateral piston, tip and groove density mismatch, compared to the earlier designs. Experiments have been carried out for temporal compression of 650 ps positively chirped laser pulses, at central wavelength 1054 nm, down to 235 fs in the tiled grating pulse compressor set up with the proposed design. Further, far field studies have been performed to show the desired compensation of the tiling errors takes place in the new compressor.

  1. Numerical design of in-line X-ray phase-contrast imaging based on ellipsoidal single-bounce monocapillary

    International Nuclear Information System (INIS)

    Sun, Weiyuan; Liu, Zhiguo; Sun, Tianxi; Peng, Song; Ma, Yongzhong; Ding, Xunliang

    2014-01-01

    A new device using an ellipsoidal single-bounce monocapillary X-ray optics was numerically designed to realize in-line X-ray phase-contrast imaging by using conventional laboratory X-ray source with a large spot. Numerical simulation results validated the effectiveness of the proposed device and approach. The ellipsoidal single-bounce monocapillary X-ray optics had potential applications in the in-line phase contrast imaging with polychromatic X-rays

  2. Numerical design of in-line X-ray phase-contrast imaging based on ellipsoidal single-bounce monocapillary

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Weiyuan; Liu, Zhiguo [The Key Laboratory of Beam Technology and Materials Modification of the Ministry of Education, Beijing Normal University, Beijing 100875 (China); College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875 (China); Beijing Radiation Center, Beijing 100875 (China); Sun, Tianxi, E-mail: stx@bnu.edu.cn [The Key Laboratory of Beam Technology and Materials Modification of the Ministry of Education, Beijing Normal University, Beijing 100875 (China); College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875 (China); Beijing Radiation Center, Beijing 100875 (China); Peng, Song [The Key Laboratory of Beam Technology and Materials Modification of the Ministry of Education, Beijing Normal University, Beijing 100875 (China); College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875 (China); Beijing Radiation Center, Beijing 100875 (China); Ma, Yongzhong [Center for Disease Control and Prevention of Beijing, Beijing 100013 (China); Ding, Xunliang [The Key Laboratory of Beam Technology and Materials Modification of the Ministry of Education, Beijing Normal University, Beijing 100875 (China); College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875 (China); Beijing Radiation Center, Beijing 100875 (China)

    2014-05-11

    A new device using an ellipsoidal single-bounce monocapillary X-ray optics was numerically designed to realize in-line X-ray phase-contrast imaging by using conventional laboratory X-ray source with a large spot. Numerical simulation results validated the effectiveness of the proposed device and approach. The ellipsoidal single-bounce monocapillary X-ray optics had potential applications in the in-line phase contrast imaging with polychromatic X-rays.

  3. Safety, pharmacokinetics, and pharmacodynamics of TV-1380, a novel mutated butyrylcholinesterase treatment for cocaine addiction, after single and multiple intramuscular injections in healthy subjects.

    Science.gov (United States)

    Cohen-Barak, Orit; Wildeman, Jacqueline; van de Wetering, Jeroen; Hettinga, Judith; Schuilenga-Hut, Petra; Gross, Aviva; Clark, Shane; Bassan, Merav; Gilgun-Sherki, Yossi; Mendzelevski, Boaz; Spiegelstein, Ofer

    2015-05-01

    Human plasma butyrylcholinesterase (BChE) contributes to cocaine metabolism and has been considered for use in treating cocaine addiction and cocaine overdose. TV-1380 is a recombinant protein composed of the mature form of human serum albumin fused at its amino terminus to the carboxy-terminus of a truncated and mutated BChE. In preclinical studies, TV-1380 has been shown to rapidly eliminate cocaine in the plasma thus forestalling entry of cocaine into the brain and heart. Two randomized, blinded phase I studies were conducted to evaluate the safety, pharmacokinetics, and pharmacodynamics of TV-1380, following single and multiple administration in healthy subjects. TV-1380 was found to be safe and well tolerated with a long half-life (43-77 hours) and showed a dose-proportional increase in systemic exposure. Consistent with preclinical results, the ex vivo cocaine hydrolysis, TV-1380 activity clearly increased upon treatment in a dose-dependent manner. In addition, there was a direct relationship between ex vivo cocaine hydrolysis (kel ) and TV-1380 serum concentrations. There was no evidence that TV-1380 affected heart rate, the uncorrected QT interval, or the heart-rate-corrected QTcF interval. TV-1380, therefore, offers a safe once-weekly therapy to increase cocaine hydrolysis. © 2015 The Authors. The Journal of Clinical Pharmacology Published by Wiley Periodicals, Inc. on behalf of American College of Clinical Pharmacology.

  4. Comparative bioavailability and pharmacokinetics of two oral formulations of flurbiprofen: a single-dose, randomized, open-label, two-period, crossover study in Pakistani subjects.

    Science.gov (United States)

    Qayyum, Aisha; Najmi, Muzammil Hasan; Abbas, Mateen

    2013-11-01

    Comparative bioavailability studies are conducted to establish the bioequivalence of generic formulation with that of branded reference formulation, providing confidence to clinicians to use these products interchangeably. This study was carried out to compare a locally manufactured formulation of flurbiprofen with that of a branded product. Twenty two healthy male adults received a single dose of flurbiprofen (100mg) either generic or branded product according to randomization scheme on each of 2 periods. Blood samples were collected and plasma flurbiprofen concentration was determined by a validated HPLC method. Pharmacokinetic parameters like AUC(0-t), AUC(0-oo), Cmax, Tmax, t½, Vd and clearance were determined. The 90% CI for the ratio of geometric means of test to reference product's pharmacokinetic variables was calculated. Pharmacokinetic parameters for two formulations were comparable. Ratio of means of AUC(0-24), AUC(0-oo) and Cmax for test to reference products and 90% CI for these ratios were within the acceptable range. The p-values calculated by TOST were much less than the specified value (p-0.05). ANOVA gave p-values which were more than the specified value (p-0.05) for sequence, subject, period and formulation. Test formulation of flurbiprofen (tablet Flurso) was found to meet the criteria for bioequivalence to branded product (tablet Ansaid) based on pharmacokinetic parameters.

  5. Hemodynamic mechanisms of the attenuated blood pressure response to mental stress after a single bout of maximal dynamic exercise in healthy subjects

    Directory of Open Access Journals (Sweden)

    F.J. Neves

    2012-07-01

    Full Text Available To determine the hemodynamic mechanisms responsible for the attenuated blood pressure response to mental stress after exercise, 26 healthy sedentary individuals (age 29 ± 8 years underwent the Stroop color-word test before and 60 min after a bout of maximal dynamic exercise on a treadmill. A subgroup (N = 11 underwent a time-control experiment without exercise. Blood pressure was continuously and noninvasively recorded by infrared finger photoplethysmography. Stroke volume was derived from pressure signals, and cardiac output and peripheral vascular resistance were calculated. Perceived mental stress scores were comparable between mental stress tests both in the exercise (P = 0.96 and control (P = 0.24 experiments. After exercise, the blood pressure response to mental stress was attenuated (pre: 10 ± 13 vs post: 6 ± 7 mmHg; P 0.05. In conclusion, a single bout of maximal dynamic exercise attenuates the blood pressure response to mental stress in healthy subjects, along with lower stroke volume and cardiac output, denoting an acute modulatory action of exercise on the central hemodynamic response to mental stress.

  6. Characterization of Decision Making Behaviors Associated with Human Systems Integration (HSI) Design Tradeoffs: Subject Matter Expert Interviews

    Science.gov (United States)

    2014-11-18

    Anticipated/Diagnosed potential user difficulty with the design • Evaluated/Mentally simulated interface use to create a storyboard HFEs with...Compared and contrasted different technologies Conducted a prototype/ storyboard review Conducted a technology demonstration Generated design

  7. Reliability-Oriented Design and Analysis of Input Capacitors in Single-Phase Transformer-less Photovoltaic Inverters

    DEFF Research Database (Denmark)

    Wang, Huai; Yang, Yongheng; Blaabjerg, Frede

    2013-01-01

    While 99% efficiency has been reported, the target of 20 years of service time imposes new challenge to cost-effective solutions for grid-connected photovoltaic (PV) inverters. Aluminum electrolytic capacitors are the weak-link in terms of reliability and lifetime in single-phase PV systems....... A reliability-oriented design guideline is proposed in this paper for the input capacitors in single-phase transformer-less PV inverters. The guideline ensures that the service time requirement is to be accomplished under different power levels and ambient temperature profiles. The theoretical analysis has been...... demonstrated by a 1 kW single-phase PV inverter....

  8. Design and Testing of a Thermostable Platform for Multimerization of Single Domain Antibodies

    Science.gov (United States)

    2012-08-01

    H.J. Properties , production, and applications of camelid single domain antibody fragments. Appl. Microbiol. Biot. 2007, 77, 13‒22. 2. Goldman...Conway, J.; Sherwood, L.J.; Fech, M.; Vo, B.; Liu, J.L.; Hayhurst, A. Thermostable llama single domain antibodies for detection of Botulinum A...antiparallel coiled-coil inserted. J. Mol. Bio. 2001, 306, 25‒35. 9. Liu, J.L.; Anderson, G.P.; Goldman, E.R. Isolation of anti- toxin single domain

  9. Design of polymetallic uranium assemblies for the development of single molecule magnets

    International Nuclear Information System (INIS)

    Chatelain, Lucile

    2016-01-01

    The study of actinide chemistry is not only essential for the development of nuclear fuel, nuclear fuel reprocessing or environmental clean up, but also for the understanding of fundamental actinide/ligand interactions and multiple bounding. The magnetic properties of polynuclear actinide molecules are of significant interest to investigate the magnetic communication between the metallic centres. Furthermore, they are highly promising for the design of molecular magnets. Uranium undergoes redox reactions due to a wide range of available oxidation states and easily forms polynuclear assemblies. However, only a few controlled synthetic routes towards these polynuclear uranium assemblies are described in the literature. In this context, the first part of this work was dedicated to the synthesis of oxo/hydroxo uranium clusters from the controlled hydrolysis of tetravalent uranium in the presence of an environmentally relevant ligand. This led to the synthesis of clusters with novel topologies, for which size could be varied as a function of the reaction conditions employed. However, the obtained clusters do not behave as SMM. In order to gain a stronger interaction between metallic centres, the cation-cation interaction was used to rationally design polynuclear uranyl(V) complexes. The isolation of uranyl(V) complexes had been limited in the past by its disproportionation, however, a fine tuning of the organic ligand and reaction conditions finally allowed to stabilise uranyl(V). We used stable uranyl(V) units as building block to form heteronuclear complexes with 3d and 4f metals with polymeric or discrete structures. The study of the magnetic properties of the uranium polynuclear assemblies was carried out and revealed single molecule or chain magnet behaviours with high energy barriers. The uranyl(V) unit was also used as a structural model for the more radioactive neptunium element, allowing the isolation of an isostructural trinuclear neptunyl(V) assembly in

  10. From fundamental studies of reactivity on single crystals to the design of catalysts

    Science.gov (United States)

    H. Larsen, Jane; Chorkendorff, Ib

    One of the prominent arguments for performing surface science studies have for many years been to improve and design new and better catalysts. Although surface science has provided the fundamental framework and tools for understanding heterogeneous catalysis until now there have been extremely few examples of actually designing new catalysts based solely on surface science studies. In this review, we shall demonstrate how a close collaboration between different fundamental disciplines like structural-, theoretical-and reactivity-studies of surfaces as well as a strong interaction with industry can have strong synergetic effects and how this was used to develop a new catalyst. As so often before the studies reviewed here were not initiated with the objective to solve a specific problem, but realizing that a new class of very stable two-dimensional alloys could be synthesized from otherwise immiscible metals made it possible to present a new solution to a specific problem in the industrial catalysis relating to methane activation in the steam reforming process. Methane is the main constituent of natural gas and it is an extremely important raw material for many large scale chemical processes such as production of hydrogen, ammonia, and methanol. In the steam reforming process methane and water are converted into a mixture of mainly hydrogen and carbon monoxide, the so-called synthesis gas. Industrially the steam reforming process usually takes place over a catalyst containing small nickel crystallites highly dispersed on a porous support material like aluminum/magnesium oxides in order to achieve a high active metal area. There is a general consensus that the rate limiting step of this process is the dissociative sticking of methane on the nickel surface. Driven by the desire to understand this step and hopefully be able to manipulate the reactivity, a large number of investigations of the methane/nickel interaction have been performed using nickel single crystals as

  11. Design and Generation of Humanized Single-chain Fv Derived from Mouse Hybridoma for Potential Targeting Application.

    Science.gov (United States)

    Khantasup, Kannika; Chantima, Warangkana; Sangma, Chak; Poomputsa, Kanokwan; Dharakul, Tararaj

    2015-12-01

    Single-chain variable antibody fragments (scFvs) are attractive candidates for targeted immunotherapy in several human diseases. In this study, a concise humanization strategy combined with an optimized production method for humanizing scFvs was successfully employed. Two antibody clones, one directed against the hemagglutinin of H5N1 influenza virus, the other against EpCAM, a cancer biomarker, were used to demonstrate the validity of the method. Heavy chain (VH) and light chain (VL) variable regions of immunoglobulin genes from mouse hybridoma cells were sequenced and subjected to the construction of mouse scFv 3-D structure. Based on in silico modeling, the humanized version of the scFv was designed via complementarity-determining region (CDR) grafting with the retention of mouse framework region (FR) residues identified by primary sequence analysis. Root-mean-square deviation (RMSD) value between mouse and humanized scFv structures was calculated to evaluate the preservation of CDR conformation. Mouse and humanized scFv genes were then constructed and expressed in Escherichia coli. Using this method, we successfully generated humanized scFvs that retained the targeting activity of their respective mouse scFv counterparts. In addition, the humanized scFvs were engineered with a C-terminal cysteine residue (hscFv-C) for site-directed conjugation for use in future targeting applications. The hscFv-C expression was extensively optimized to improve protein production yield. The protocol yielded a 20-fold increase in production of hscFv-Cs in E. coli periplasm. The strategy described in this study may be applicable in the humanization of other antibodies derived from mouse hybridoma.

  12. A Rational Engineering Strategy for Designing Protein A-Binding Camelid Single-Domain Antibodies

    Science.gov (United States)

    Henry, Kevin A.; Sulea, Traian; van Faassen, Henk; Hussack, Greg; Purisima, Enrico O.; MacKenzie, C. Roger; Arbabi-Ghahroudi, Mehdi

    2016-01-01

    Staphylococcal protein A (SpA) and streptococcal protein G (SpG) affinity chromatography are the gold standards for purifying monoclonal antibodies (mAbs) in therapeutic applications. However, camelid VHH single-domain Abs (sdAbs or VHHs) are not bound by SpG and only sporadically bound by SpA. Currently, VHHs require affinity tag-based purification, which limits their therapeutic potential and adds considerable complexity and cost to their production. Here we describe a simple and rapid mutagenesis-based approach designed to confer SpA binding upon a priori non-SpA-binding VHHs. We show that SpA binding of VHHs is determined primarily by the same set of residues as in human mAbs, albeit with an unexpected degree of tolerance to substitutions at certain core and non-core positions and some limited dependence on at least one residue outside the SpA interface, and that SpA binding could be successfully introduced into five VHHs against three different targets with no adverse effects on expression yield or antigen binding. Next-generation sequencing of llama, alpaca and dromedary VHH repertoires suggested that species differences in SpA binding may result from frequency variation in specific deleterious polymorphisms, especially Ile57. Thus, the SpA binding phenotype of camelid VHHs can be easily modulated to take advantage of tag-less purification techniques, although the frequency with which this is required may depend on the source species. PMID:27631624

  13. Small-Signal Modeling, Stability Analysis and Design Optimization of Single-Phase Delay-Based PLLs

    DEFF Research Database (Denmark)

    Golestan, Saeed; Guerrero, Josep M.; Vidal, Ana

    2016-01-01

    Generally speaking, designing single-phase phaselocked loops (PLLs) is more complicated than three-phase ones, as their implementation often involves the generation of a fictitious orthogonal signal for the frame transformation. In recent years, many approaches to generate the orthogonal signal...... these issues and explore new methods to enhance their performance. The stability analysis, control design guidelines and performance comparison with the state-of-the-art PLLs are presented as well....

  14. Design of Circular, Square, Single, and Multi-layer Induction Coils for Electromagnetic Priming Using Inductance Estimates

    Science.gov (United States)

    Fritzsch, Robert; Kennedy, Mark W.; Aune, Ragnhild E.

    2018-02-01

    Special induction coils used for electro magnetic priming of ceramic foam filters in liquid metal filtration have been designed using a combination of analytical and finite element modeling. Relatively simple empirical equations published by Wheeler in 1928 and 1982 have been used during the design process. The equations were found to accurately predict the z-component of the magnetic flux densities of both single- and multi-layer coils as verified both experimentally and by using COMSOL® 5.1 multiphysics simulations.

  15. Design of a box trainer for objective assessment of technical skills in single-port surgery

    NARCIS (Netherlands)

    Horeman, Tim; Sun, Siyu; Tuijthof, Gabrielle J. M.; Jansen, Frank William; Meijerink, Jeroen W. J. H. J.; Dankelman, Jenny

    2015-01-01

    Laparoscopic single-port (SP) surgery uses only a single entry point for all instruments. The approach of SP has been applied in multiple laparoscopic disciplines owing to its improved cosmetic result. However, in SP surgery, instrument movements are further restricted, resulting in increased

  16. DESIGN METHODOLOGIES AND TOOLS FOR SINGLE-FLUX QUANTUM LOGIC CIRCUITS

    Science.gov (United States)

    2017-10-01

    Determine GLOBAL CLK DEF or NETLIST Produce results END STA TOOL Determine clocking scheme Determine system clock Determine slack and other path...times. It also enables the designer to input a target time for the design which produces a slack value. Positive slack meaning that the critical time is...less than the target time and the design meets the speed requirements set by the designer. A negative slack value indicates that the design does

  17. Middle-School Teachers' Understanding and Teaching of the Engineering Design Process: A Look at Subject Matter and Pedagogical Content Knowledge

    Science.gov (United States)

    Hynes, Morgan M.

    2012-01-01

    This paper reports on research investigating six middle school teachers without engineering degrees as they taught an engineering unit on the engineering design process. Videotaped classroom sessions and teacher interviews were analyzed to understand the subject matter and pedagogical content knowledge the teachers used and developed as they…

  18. Esthetic Evaluation of Anterior Single-Tooth Implants with Different Abutment Designs - Patients' Satisfaction Compared to Dentists' Observations

    NARCIS (Netherlands)

    Patil, Ratnadeep; Gresnigt, Marco M M; Mahesh, Kavita; Dilbaghi, Anjali; Cune, Marco S

    Purpose: To correlate patients' satisfaction and dentists' observations regarding two abutment designs used for single crowns in the esthetic zone: a divergent one (control) and a curved one (experimental), with special emphasis on muco-gingival esthetics. Materials and Methods: Twenty-six patients

  19. Therapeutic Assessment for Preadolescent Boys with Oppositional Defiant Disorder: A Replicated Single-Case Time-Series Design

    Science.gov (United States)

    Smith, Justin D.; Handler, Leonard; Nash, Michael R.

    2010-01-01

    The Therapeutic Assessment (TA) model is a relatively new treatment approach that fuses assessment and psychotherapy. The study examines the efficacy of this model with preadolescent boys with oppositional defiant disorder and their families. A replicated single-case time-series design with daily measures is used to assess the effects of TA and to…

  20. Explaining Variance and Identifying Predictors of Children's Communication via a Multilevel Model of Single-Case Design Research: Brief Report

    Science.gov (United States)

    Ottley, Jennifer Riggie; Ferron, John M.; Hanline, Mary Frances

    2016-01-01

    The purpose of this study was to explain the variability in data collected from a single-case design study and to identify predictors of communicative outcomes for children with developmental delays or disabilities (n = 4). Using SAS® University Edition, we fit multilevel models with time nested within children. Children's level of baseline…

  1. Meta-Analysis of Single-Case Design Research on Self-Regulatory Interventions for Academic Performance

    Science.gov (United States)

    Perry, Valerie; Albeg, Loren; Tung, Catherine

    2012-01-01

    The current study examined the effects of self-regulatory interventions on reading, writing, and math by conducting a meta-analysis of single-case design research. Self-regulatory interventions have promise as an effective approach that is both minimally invasive and involves minimal resources. Effects of the interventions were analyzed by…

  2. Problem Solving and Creativity and Design: What Influence Do They Have on Girls' Interest in STEM Subject Areas?

    Science.gov (United States)

    Cooper, Robyn; Heaverlo, Carol

    2013-01-01

    For girls there is a distinct loss in interest, lack of confidence, and decline in positive attitudes toward STEM subject areas that begins early on in their academic experience and increases with age. According to the National Academy of Engineering, students need to begin associating the possibilities in STEM fields with the need for creativity…

  3. Design and analysis of linear oscillatory single-phase permanent magnet generator for free-piston stirling engine systems

    Science.gov (United States)

    Kim, Jeong-Man; Choi, Jang-Young; Lee, Kyu-Seok; Lee, Sung-Ho

    2017-05-01

    This study focuses on the design and analysis of a linear oscillatory single-phase permanent magnet generator for free-piston stirling engine (FPSE) systems. In order to implement the design of linear oscillatory generator (LOG) for suitable FPSEs, we conducted electromagnetic analysis of LOGs with varying design parameters. Then, detent force analysis was conducted using assisted PM. Using the assisted PM gave us the advantage of using mechanical strength by detent force. To improve the efficiency, we conducted characteristic analysis of eddy-current loss with respect to the PM segment. Finally, the experimental result was analyzed to confirm the prediction of the FEA.

  4. Design and analysis of linear oscillatory single-phase permanent magnet generator for free-piston stirling engine systems

    Directory of Open Access Journals (Sweden)

    Jeong-Man Kim

    2017-05-01

    Full Text Available This study focuses on the design and analysis of a linear oscillatory single-phase permanent magnet generator for free-piston stirling engine (FPSE systems. In order to implement the design of linear oscillatory generator (LOG for suitable FPSEs, we conducted electromagnetic analysis of LOGs with varying design parameters. Then, detent force analysis was conducted using assisted PM. Using the assisted PM gave us the advantage of using mechanical strength by detent force. To improve the efficiency, we conducted characteristic analysis of eddy-current loss with respect to the PM segment. Finally, the experimental result was analyzed to confirm the prediction of the FEA.

  5. Design and prototyping of self-centering optical single-mode fiber alignment structures

    International Nuclear Information System (INIS)

    Ebraert, Evert; Gao, Fei; Thienpont, Hugo; Van Erps, Jürgen; Beri, Stefano; Watté, Jan

    2016-01-01

    The European Commission’s goal of providing each European household with at least a 30 Mb s −1 Internet connection by 2020 would be facilitated by a widespread deployment of fibre-to-the-home, which would in turn be sped up by the development of connector essential components, such as high-precision alignment features. Currently, the performance of state-of-the-art physical contact optical fiber connectors is limited by the tolerance on the cladding of standard telecom-grade single-mode fiber (SMF), which is typically smaller than  ±1 μ m. We propose to overcome this limit by developing micro-spring-based self-centering alignment structures (SCAS) for SMF-connectors. We design these alignment structures with robustness and low-cost replication in mind, allowing for large-scale deployment. Both theoretical and finite element analysis (FEA) models are used to determine the optimal dimensions of the beams of which the micro-springs of the SCAS are comprised. Two topologies of the SCAS, consisting of three and four micro-springs respectively, are investigated for two materials: polysulfone (PSU) and polyetherimide (PEI). These materials hold great potential for high-performance fiber connectors while being compatible with low-cost production and with the harsh environmental operation conditions of those connectors. The theory and FEA agree well (<3% difference) for a simple micro-spring. When including a pedestal on the micro-spring (to bring it further away from the fiber) and for shorter spring lengths the agreement worsens. This is due to spring compression effects not being taken into account in our theoretical model. Prototypes are successfully fabricated using deep proton writing and subsequently characterized. The controlled insertion of an SMF in the SCAS is investigated and we determine that a force of 0.11 N is required. The fiber insertion also causes an out-of-plane deformation of the micro-springs in the SCAS of about 7 μ m, which is no

  6. Design of single-polarization wavelength splitter based on photonic crystal fiber.

    Science.gov (United States)

    Zhang, Shanshan; Zhang, Weigang; Geng, Pengcheng; Li, Xiaolan; Ruan, Juan

    2011-12-20

    A new single-polarization wavelength splitter based on the photonic crystal fiber (PCF) has been proposed. The full-vector finite-element method (FEM) is applied to analyze the single-polarization single-mode guiding properties. Splitting of two different wavelengths is realized by adjusting the structural parameters. The semi-vector three-dimensional beam propagation method is employed to confirm the wavelength splitting characteristics of the PCF. Numerical simulations show that the wavelengths of 1.3 μm and 1.55 μm are split for a fiber length of 10.7 mm with single-polarization guiding in each core. The crosstalk between the two cores is low over appreciable optical bandwidths.

  7. Design of a Single Motor Based Leg Structure with the Consideration of Inherent Mechanical Stability

    Science.gov (United States)

    Taha Manzoor, Muhammad; Sohail, Umer; Noor-e-Mustafa; Nizami, Muhammad Hamza Asif; Ayaz, Yasar

    2017-07-01

    The fundamental aspect of designing a legged robot is constructing a leg design that is robust and presents a simple control problem. In this paper, we have successfully designed a robotic leg based on a unique four bar mechanism with only one motor per leg. The leg design parameters used in our platform are extracted from design principles used in biological systems, multiple iterations and previous research findings. These principles guide a robotic leg to have minimal mechanical passive impedance, low leg mass and inertia, a suitable foot trajectory utilizing a practical balance between leg kinematics and robot usage, and the resultant inherent mechanical stability. The designed platform also exhibits the key feature of self-locking. Theoretical tools and software iterations were used to derive these practical features and yield an intuitive sense of the required leg design parameters.

  8. Design, Fabrication and Initial Testing of a Large Bore Single Aperture 1 m Long Superconducting Dipole Made with Phenolic Inserts

    CERN Document Server

    Boschmann, H; Kirby, G A; Lucas, J; Ostojic, R; Russenschuck, Stephan; Siemko, A; Vanenkov, I; Weterings, W

    1997-01-01

    In the framework of the LHC magnet development programme, a large bore single aperture 1-meter long superconducting dipole has been built in collaboration with HOLEC. The magnet features a single layer coil wound using the LHC main dipole outer layer cable, phenolic inserts, and a keyed two part structural iron yoke. This paper presents the magnetic and mechanical design and optimisation of the magnet. We describe the coil winding and curing, and present the construction and assembly procedures. Finally we report on the mechanical behaviour during assembly and cooling, and present the magnet training behaviour.

  9. Meteorological Parameters and the Onset of Chest Pain in Subjects with Acute ST-Elevation Myocardial Infarction: an Eight-Year, Single-Center Study in China

    Directory of Open Access Journals (Sweden)

    En-Zhi Jia

    2014-10-01

    Full Text Available Objective: The purpose of this study was to investigate the influence of weather on the occurrence of acute ST-elevation myocardial infarction in Chinese subjects. Methods: Weather and climate data, as well as the occurrence of STEMI, were monitored at 2 am, 8 am, 2 pm, and 8 pm between 2003 and 2010. Generalized additive Poisson models were utilized to plot the numbers of patients with STEMI within 6 hour intervals against climatological variations, after accounting for the effects of the hour and season. Results: The inclusion of meteorological conditions, including observed atmospheric pressure (hPa, hectopascal variations during the previous three hours and temperature (°C, degrees Celsius, significantly affected the occurrence of STEMI, as measured every six hours. Compared with the 50th percentile of atmospheric pressure variations, the RRs (95% CI for the first percentile, 10th percentile, 25th percentile, 75th percentile, 90th percentile, and 99th percentile of atmospheric pressure variation over lag 0 were 1.66 (1.36∼2.03, 1.47 (1.30∼1.67, 1.22 (1.12∼1.33, 1.16 (1.07∼1.25, 1.27 (1.13∼1.43, and 1.16 (0.92∼1.46, respectively. Compared to the 50th percentile of temperature, the RRs (95% CI for the first percentile, 10th percentile, 25th percentile, 75th percentile, 90th percentile, and 99th percentile of temperature over lag 0 were 0.58 (0.40∼0.83, 0.60 (0.46∼0.78, 0.69 (0.57∼0.83, 1.33 (1.14∼1.56, 1.39 (1.13∼1.71, and 1.17 (0.84∼1.63, respectively. Conclusions: Based on the eight-year, single-center study, significant relationships were observed among the occurrence of STEMI and atmospheric pressure variations during the previous three hours and temperature after account for long-term time trends.

  10. Concentrations of garenoxacin in plasma, bronchial mucosa, alveolar macrophages and epithelial lining fluid following a single oral 600 mg dose in healthy adult subjects.

    Science.gov (United States)

    Andrews, J; Honeybourne, D; Jevons, G; Boyce, M; Wise, R; Bello, A; Gajjar, D

    2003-03-01

    A microbiological assay was used to measure concentrations of garenoxacin (BMS-284756) in plasma, bronchial mucosa (BM), alveolar macrophages (AM) and epithelial lining fluid (ELF), following a single 600 mg oral dose. Twenty-four healthy subjects were allocated into four nominal time intervals after the dose, 2.5-3.5, 4.5-5.5, 10.5-11.5 and 23.5-24.5 h. Mean concentrations in plasma, BM, AM and ELF, respectively, for the four nominal time windows were for 2.5-3.5 h 10.0 mg/L (S.D. 2.8), 7.0 mg/kg (S.D. 1.3), 106.1 mg/L (S.D. 60.3) and 9.2 mg/L (S.D. 3.6); 4.5-5.5 h 8.7 mg/L (S.D. 2.2), 6.0 mg/kg (S.D. 1.9), 158.6 mg/L (S.D. 137.4) and 14.3 mg/L (S.D. 8.2); 10.5-11.5 h 6.1 mg/L (S.D. 1.9), 4.0 mg/kg (S.D. 1.4), 76.0 mg/L (S.D. 47.7) and 7.9 mg/L (S.D. 4.6); and 23.5-24.5 h 2.1 mg/L (S.D. 0.5), 1.7 mg/kg (S.D. 0.7), 30.7 mg/L (S.D. 12.9) and 3.3 mg/L (S.D. 2.3). Concentrations at all sites exceeded MIC(90)s for the common respiratory pathogens Haemophilus influenzae (0.03 mg/L), Moraxella catarrhalis (0.015 mg/L) and Streptococcus pneumoniae (0.06 mg/L). These data suggest that garenoxacin should be effective in the treatment of community-acquired pneumonia and chronic obstructive pulmonary disease.

  11. Collaboration Between Art Teacher Students and Communication and Digital Media Students Promoting Subject Specific Didactics in Digital Visual Learning Design

    DEFF Research Database (Denmark)

    Buhl, Mie; Skov, Kirsten

    . Student art teachers and teacher trainers took part in the design process performed by communication students. The project took its point of the departure in the act of Danish teacher education where student teachers must be educated in the practical use of digital visual media for art practices aiming......, drawing or video. Thus, the project suggested the development of a visual learning design for achieving augmented reality (AR) experiences in urban environments and sharing them on social media. The purpose was to explore adequate approaches to work with digital media in visual arts education based...... on practices and reflective processes. The theoretical framework for our discussion of the empirical project draws on current discussions of learning designs and digital media in visual arts education (Peppler 2010, Rasmussen 2015, Buhl & Ejsing-Duun, 2015; Buhl, 2016). Methodology The choice of empirical...

  12. Farmers’ Cohort for Agricultural Work-Related Musculoskeletal Disorders (FARM) Study: Study Design, Methods, and Baseline Characteristics of Enrolled Subjects

    Science.gov (United States)

    Jo, Hannae; Baek, Sora; Park, Hee-won; Lee, Sang-Ah; Moon, Jiyoung; Yang, Jae E.; Kim, Ki Sung; Kim, Jee Yong; Kang, Eun Kyoung

    2016-01-01

    Background The ongoing Farmers’ Cohort for Agricultural Work-related Musculoskeletal Disorders (FARM) study was developed to evaluate health status and related factors in farmers. Methods Farmers in Kangwon Province, South Korea, were recruited. Baseline characteristics were determined using questionnaires about sociodemographic and health characteristics and agricultural work-related factors. In addition, laboratory examinations (lumbar spinal radiography and serologic testing) were conducted. Results The FARM study covers eight rural areas and recruited 1013 subjects (534 women; mean [standard deviation {SD}] age, 57.2 [7.5] years). Musculoskeletal pain in multiple areas was reported by 925 subjects (91.3%), and low back pain (63.8%) was the most frequent site of pain. Farmer’s Stress Inventory (mean [SD], 77.7 [10.2]; range, 28–112] and subjective stress index (mean [SD], 5.3 [2.4]; range, 0–10) were above median scale values, reflecting a stressful condition, while the EuroQol-5D-3L index and the EuroQol-Visual Analog Scale scores were high (mean [SD], 0.9 [0.1]; range −0.171–1 and mean [SD], 67.7 [18.7]; range 0–100, respectively), reflecting good life quality. In total, 53% of participants had worked in farming for more than 30 years, and workers involved in dry-field farming comprised the largest subgroup (41.5%). Most participants (94.3%) had no more than a high school education, and families with annual income below 20 million won constituted the largest subgroup (36.3%). Conclusions The FARM study may provide data on the current health status and related sociodemographic and agricultural work-related risk factors in Korean farmers, with the goal of providing a scientific basis for developing coping interventions and preventive strategies. PMID:26235456

  13. The effect of shoe design and lateral wedges on knee load and neuromuscular control in healthy subjects during walking

    DEFF Research Database (Denmark)

    Mølgaard, Carsten Møller; Kersting, Uwe G.

    2013-01-01

    and second peak knee adduction moments. However, the variability of this moment between shoe designs was of similar magnitude as the effect of laterally wedged insoles. Only marginal changes in muscle activity for gastrocnemius when walking with the wedged Oxford shoe were revealed. Conclusion: Lateral...

  14. A numerical design approach for single amplifier, Active-RC Butterworth filter of order 5

    OpenAIRE

    Gaunholt, Hans

    2007-01-01

    A design method is presented for the design of all pole lowpass active-RC filters applying operational amplifiers. The operational amplifier model used is the integrator model: omegat/s where omegat is the unity gain frequency. The design method is used for the design of a fifth order Butterworth filter applying just one operational amplifier coupled as a unity gain amplifier. It is shown that the influence from the real operational amplifier may be reduced by trimming just one resistor in th...

  15. Design considerations for a Space Shuttle Main Engine turbine blade made of single crystal material

    Science.gov (United States)

    Abdul-Aziz, A.; August, R.; Nagpal, V.

    1993-01-01

    Nonlinear finite-element structural analyses were performed on the first stage high-pressure fuel turbopump blade of the Space Shuttle Main Engine. The analyses examined the structural response and the dynamic characteristics at typical operating conditions. Single crystal material PWA-1480 was considered for the analyses. Structural response and the blade natural frequencies with respect to the crystal orientation were investigated. The analyses were conducted based on typical test stand engine cycle. Influence of combined thermal, aerodynamic, and centrifugal loadings was considered. Results obtained showed that the single crystal secondary orientation effects on the maximum principal stresses are not highly significant.

  16. Cavity design for single-frequency Yb:YAB microchip lasers

    International Nuclear Information System (INIS)

    Burns, P.; Dawes, J.M.; Piper, J.A.

    2000-01-01

    Full text: We have proposed a cavity configuration for compact, stable, single-frequency operation in Yb:YAB. Modelling of the cavity output in the infrared and green has shown that sufficient mode discrimination can be achieved within the tuning range of the crystal. Experiments are planned to demonstrate efficient single longitudinal mode infrared operation of the devices that can be extended to include the self-frequency-doubled output. Details of the modelling and preliminary results will be presented at the conference

  17. Image quality and radiation dose of single heartbeat 640-slice coronary CT angiography: A comparison between patients with chronic Atrial Fibrillation and subjects in normal sinus rhythm by propensity analysis

    International Nuclear Information System (INIS)

    Di Cesare, Ernesto; Gennarelli, Antonio; Di Sibio, Alessandra; Felli, Valentina; Splendiani, Alessandra; Gravina, Giovanni Luca; Masciocchi, Carlo

    2015-01-01

    Highlights: •Atrial Fibrillation (AF) may affect CCTA image quality. •We compare the results of single heartbeat CCTA in subjects with chronic AF and in sinus rhythm. •Single heartbeat CCTA may be feasible also in subjects with cAF and HR <72 bpm. •In cAF patients with heart rate higher than 72 bpm, CCTA has more movement-associated artefacts. •Mean effective dose of single heartbeat CCTA in cAF group was higher than in sinus rhythm one. -- Abstract: Objectives: To evaluate image quality and radiation dose of single heartbeat 640-slice coronary CT angiography (CCTA) in patients with chronic Atrial Fibrillation (cAF) in comparison with subjects in normal sinus rhythm. Methods: A cohort of 71 patients with cAF was matched with 71 subjects in normal sinus rhythm (NSR) and HR ≤ 65 bpm using a matched by propensity analysis. All subjects underwent a single heartbeat CCTA with prospective gating. In subjects with cAF, we manually established the acquisition of data only from a single heartbeat. Mean effective dose and image quality, with both objective and subjective measures, were assessed. Results: 96.4% of all segments in the cAF group had diagnostic image quality. The rate of subjects with at least one non-diagnostic segment was 14% and 2.8% (p = 0.031) in the cAF and NRS groups, respectively. In the cAF group, the percentage of patients with at least one non-diagnostic segment for acquisition HR ≤ 72 was 1.8% (1/55), and it did not significantly differ from the NSR group (2.8%; 2/71) (p = 1.0). Objective quality parameters did not show a statistically significant difference between the two groups. The mean effective dose was 4.24 ± 1.24 mSv in the cAF group and 2.67 ± 0.5 mSv in the sinus rhythm group (p < 0.0001) with an increase by 59% in the cAF group with respect to the SNR group. Conclusions: A single heartbeat acquisition protocol with a 640-slice prospectively ECG-triggered CT angiography may be feasible in patients with cAF and HR below 72

  18. Image quality and radiation dose of single heartbeat 640-slice coronary CT angiography: A comparison between patients with chronic Atrial Fibrillation and subjects in normal sinus rhythm by propensity analysis

    Energy Technology Data Exchange (ETDEWEB)

    Di Cesare, Ernesto, E-mail: ernesto.dicesare@cc.univaq.it [Department of Biotechnological and Applied Clinical Sciences, Division of Radiotherapy, Laboratory of Radiobiology, University of L’Aquila (Italy); Gennarelli, Antonio; Di Sibio, Alessandra; Felli, Valentina; Splendiani, Alessandra [Department of Biotechnological and Applied Clinical Sciences, Division of Radiology, Laboratory of Radiobiology, University of L’Aquila (Italy); Gravina, Giovanni Luca [Department of Biotechnological and Applied Clinical Sciences, Division of Radiotherapy, Laboratory of Radiobiology, University of L’Aquila (Italy); Masciocchi, Carlo [Department of Biotechnological and Applied Clinical Sciences, Division of Radiology, Laboratory of Radiobiology, University of L’Aquila (Italy)

    2015-04-15

    Highlights: •Atrial Fibrillation (AF) may affect CCTA image quality. •We compare the results of single heartbeat CCTA in subjects with chronic AF and in sinus rhythm. •Single heartbeat CCTA may be feasible also in subjects with cAF and HR <72 bpm. •In cAF patients with heart rate higher than 72 bpm, CCTA has more movement-associated artefacts. •Mean effective dose of single heartbeat CCTA in cAF group was higher than in sinus rhythm one. -- Abstract: Objectives: To evaluate image quality and radiation dose of single heartbeat 640-slice coronary CT angiography (CCTA) in patients with chronic Atrial Fibrillation (cAF) in comparison with subjects in normal sinus rhythm. Methods: A cohort of 71 patients with cAF was matched with 71 subjects in normal sinus rhythm (NSR) and HR ≤ 65 bpm using a matched by propensity analysis. All subjects underwent a single heartbeat CCTA with prospective gating. In subjects with cAF, we manually established the acquisition of data only from a single heartbeat. Mean effective dose and image quality, with both objective and subjective measures, were assessed. Results: 96.4% of all segments in the cAF group had diagnostic image quality. The rate of subjects with at least one non-diagnostic segment was 14% and 2.8% (p = 0.031) in the cAF and NRS groups, respectively. In the cAF group, the percentage of patients with at least one non-diagnostic segment for acquisition HR ≤ 72 was 1.8% (1/55), and it did not significantly differ from the NSR group (2.8%; 2/71) (p = 1.0). Objective quality parameters did not show a statistically significant difference between the two groups. The mean effective dose was 4.24 ± 1.24 mSv in the cAF group and 2.67 ± 0.5 mSv in the sinus rhythm group (p < 0.0001) with an increase by 59% in the cAF group with respect to the SNR group. Conclusions: A single heartbeat acquisition protocol with a 640-slice prospectively ECG-triggered CT angiography may be feasible in patients with cAF and HR below 72

  19. A Comparison of Single-Gender Classes and Traditional, Coeducational Classes on Student Academic Achievement, Discipline Referrals, and Attitudes toward Subjects

    Science.gov (United States)

    Smith, Debra Messenger

    2010-01-01

    In recent years, there has been a resurgence of interest in single gender education. Emerging science has proven that boys and girls learn differently. This study compared fifth grade single-gender classes to fifth grade traditional, coeducational classes in the same urban middle school. The following were compared: students' academic achievement;…

  20. Evaluation of a Direct-Instruction Intervention to Improve Movement and Preliteracy Skills among Young Children: A Within-Subject Repeated-Measures Design.

    Science.gov (United States)

    Bedard, Chloe; Bremer, Emily; Campbell, Wenonah; Cairney, John

    2017-01-01

    School readiness involves the development of foundational skills such as emergent literacy and fundamental movement skills as well as the capacity to attentively engage in instructional situations. Children do not develop these skills naturally; therefore, they need the opportunity to develop these skills in their early years prior to entering school. The objective of the current study was to evaluate the effectiveness and feasibility of a direct-instruction movement and preliteracy intervention in children aged 3-4 years. A within-subject repeated-measures design, embedded within a wait-list control study, was used to evaluate the intervention. The intervention was run across 10 weeks with 1 h weekly sessions. Each weekly session consisted of 30-min of movement skill instruction (e.g., through single-step acquisition strategies), 15-min of free play during which time children had access to a variety of equipment (e.g., balls, hula hoops, etc.) or toys (e.g., puzzles, building blocks), and a 15-min interactive reading circle during which children read a storybook and were taught 1-2 preliteracy skills (e.g., alphabet knowledge, narrative knowledge, etc.). A convenience sample of 11 children (mean age = 45.6 months, SD = 7.3) was recruited. All children were assessed four times: baseline (Time 1), pre-intervention (Time 2), post-intervention (Time 3), and 5-week follow-up (Time 4). Gross motor skills and preliteracy skills were assessed at each time point. There was a statistically significant effect of time on the change in gross motor skills (Wilks' lambda = 0.09, p  = .002), print-concept skills (Wilks' lambda = 0.09, p  = .001), and alphabet knowledge (Wilks' lambda = 0.29, p  = .046). Post hoc analyses reveal non-significant changes between time 1 and 2 for motor and print-concept skills and significant changes in all three outcomes between time 2 and time 3. Participation in a direct-instruction movement and preliteracy

  1. Evaluation of a Direct-Instruction Intervention to Improve Movement and Preliteracy Skills among Young Children: A Within-Subject Repeated-Measures Design

    Directory of Open Access Journals (Sweden)

    Chloe Bedard

    2018-01-01

    Full Text Available ObjectiveSchool readiness involves the development of foundational skills such as emergent literacy and fundamental movement skills as well as the capacity to attentively engage in instructional situations. Children do not develop these skills naturally; therefore, they need the opportunity to develop these skills in their early years prior to entering school. The objective of the current study was to evaluate the effectiveness and feasibility of a direct-instruction movement and preliteracy intervention in children aged 3–4 years.MethodsA within-subject repeated-measures design, embedded within a wait-list control study, was used to evaluate the intervention. The intervention was run across 10 weeks with 1 h weekly sessions. Each weekly session consisted of 30-min of movement skill instruction (e.g., through single-step acquisition strategies, 15-min of free play during which time children had access to a variety of equipment (e.g., balls, hula hoops, etc. or toys (e.g., puzzles, building blocks, and a 15-min interactive reading circle during which children read a storybook and were taught 1–2 preliteracy skills (e.g., alphabet knowledge, narrative knowledge, etc.. A convenience sample of 11 children (mean age = 45.6 months, SD = 7.3 was recruited. All children were assessed four times: baseline (Time 1, pre-intervention (Time 2, post-intervention (Time 3, and 5-week follow-up (Time 4. Gross motor skills and preliteracy skills were assessed at each time point.ResultsThere was a statistically significant effect of time on the change in gross motor skills (Wilks’ lambda = 0.09, p = .002, print-concept skills (Wilks’ lambda = 0.09, p = .001, and alphabet knowledge (Wilks’ lambda = 0.29, p = .046. Post hoc analyses reveal non-significant changes between time 1 and 2 for motor and print-concept skills and significant changes in all three outcomes between time 2 and time 3.ConclusionParticipation in a

  2. The Iterative Use of Single Case Research Designs to Advance the Science of EI/ECSE

    Science.gov (United States)

    Barton, Erin E.; Ledford, Jennifer R.; Lane, Justin D.; Decker, Jessica; Germansky, Sara E.; Hemmeter, Mary Louise; Kaiser, Ann

    2016-01-01

    Research in early intervention/early childhood special education (EI/ECSE) is focused on identifying effective practices related to positive outcomes for young children with disabilities and their families. Individual responses to evidence-based practices are often variable, and non-responders are common. Single case research (SCR) might be…

  3. Design parameters for voltage-controllable directed assembly of single nanoparticles

    NARCIS (Netherlands)

    Porter, Benjamin F.; Abelmann, Leon; Bhaskaran, Harish

    2013-01-01

    Techniques to reliably pick-and-place single nanoparticles into functional assemblies are required to incorporate exotic nanoparticles into standard electronic circuits. In this paper we explore the use of electric fields to drive and direct the assembly process, which has the advantage of being

  4. Single-Case Design and Evaluation in R: An Introduction and Tutorial for School Psychologists

    Science.gov (United States)

    McGill, Ryan J.

    2017-01-01

    For the appraisal of single-case intervention data, school psychologists have been encouraged to focus most, if not all, of their interpretive weight on the visual inspection of graphed data. However, existing software programs provide practitioners with limited features for systematic visual inspection. R (R Development Core Team, 2014) is a…

  5. The Impact of Psychotherapeutic Reiki on Anxiety and Mindfulness: A Single-Case Design

    Science.gov (United States)

    Webster, Lindsay C.

    2016-01-01

    Reiki healing is one of several complementary and integrative therapies becoming increasingly prevalent in mental health counseling. It has been identified in the medical field for its usefulness in treating anxiety, depression, distress, and pain but has rarely been studied for its counseling impact on client wellness. I conducted single-case…

  6. Design and Implementation of Wireless Energy Meter System for Monitoring the Single Phase Supply

    OpenAIRE

    U. V, Prashanth B.

    2013-01-01

    Wireless energy meter is a system developed to serve as a basic single-phase energy meter with advanced functionalities such as Peak hour setting, Peak load setting Wireless reading transmission; further the system eliminates the role of a Meter Reader.

  7. Single Event Upset Energy Dependence In a Buck-Converter Power Supply Design

    CERN Document Server

    Drake, G; The ATLAS collaboration; Gopalakrishnan, A; Mahadik, S; Mellado, B; Proudfoot, J; Reed, R; Senthilkumaran, A; Stanek, R

    2012-01-01

    We present a study of Single Event Upsets (SEU) performed on a commercial pulse-width modulator controller chip for switching power supplies. We performed tests to study the probability of an SEU occurring as a function of incident particle (hadron) energy. We discuss the performance of the circuit, and present a solution using external circuitry to effectively eliminate the effect.

  8. Thermal design of a modern, air-conditioned, single-floor, solar-powered desert house

    KAUST Repository

    Serag-Eldin, M. A.

    2011-01-01

    The paper presents a thermal analysis of a single-floor, solar-powered desert house. The house is air-conditioned and provides all modern comforts and facilities. Electrical power, which drives the entire energy system, is generated by roof

  9. Collaboration between student art teachers and communication and digital media students promoting subject specific didactics in digital visual learning design

    DEFF Research Database (Denmark)

    Skov, Kirsten; Buhl, Mie

    into account. Our discussion of the potential for developing digital learning application from a collaborative approach is based on the visual design products, interviews and written reports, as well as shared experiences from the stakeholders in the project. Results: The project revealed three digital visual......=pdf Dunleavy, M. & Dede, C. (2014). Augmented reality teaching and learning. in. J.M. Spector, M.D. Merrill, J. Elen & M.J. Bishop (eds), The handbook og research for educational communications and technology New York: Springer http://isites.harvard.edu/fs/docs/icb.topic1116077.files....../DunleavyDedeARfinal.pdf Rasmussen, H. (2015). Digital Picture Production and Picture aesthetic Competency in It-didactic Design. Risk and opportunities for visual arts education in Europe. Proceedings, InSEA conferene, Lisbon, Portugal...

  10. The Design of a Single-Bit CMOS Image Sensor for Iris Recognition Applications

    Directory of Open Access Journals (Sweden)

    Keunyeol Park

    2018-02-01

    Full Text Available This paper presents a single-bit CMOS image sensor (CIS that uses a data processing technique with an edge detection block for simple iris segmentation. In order to recognize the iris image, the image sensor conventionally captures high-resolution image data in digital code, extracts the iris data, and then compares it with a reference image through a recognition algorithm. However, in this case, the frame rate decreases by the time required for digital signal conversion of multi-bit digital data through the analog-to-digital converter (ADC in the CIS. In order to reduce the overall processing time as well as the power consumption, we propose a data processing technique with an exclusive OR (XOR logic gate to obtain single-bit and edge detection image data instead of multi-bit image data through the ADC. In addition, we propose a logarithmic counter to efficiently measure single-bit image data that can be applied to the iris recognition algorithm. The effective area of the proposed single-bit image sensor (174 × 144 pixel is 2.84 mm2 with a 0.18 μm 1-poly 4-metal CMOS image sensor process. The power consumption of the proposed single-bit CIS is 2.8 mW with a 3.3 V of supply voltage and 520 frame/s of the maximum frame rates. The error rate of the ADC is 0.24 least significant bit (LSB on an 8-bit ADC basis at a 50 MHz sampling frequency.

  11. The Design of a Single-Bit CMOS Image Sensor for Iris Recognition Applications.

    Science.gov (United States)

    Park, Keunyeol; Song, Minkyu; Kim, Soo Youn

    2018-02-24

    This paper presents a single-bit CMOS image sensor (CIS) that uses a data processing technique with an edge detection block for simple iris segmentation. In order to recognize the iris image, the image sensor conventionally captures high-resolution image data in digital code, extracts the iris data, and then compares it with a reference image through a recognition algorithm. However, in this case, the frame rate decreases by the time required for digital signal conversion of multi-bit digital data through the analog-to-digital converter (ADC) in the CIS. In order to reduce the overall processing time as well as the power consumption, we propose a data processing technique with an exclusive OR (XOR) logic gate to obtain single-bit and edge detection image data instead of multi-bit image data through the ADC. In addition, we propose a logarithmic counter to efficiently measure single-bit image data that can be applied to the iris recognition algorithm. The effective area of the proposed single-bit image sensor (174 × 144 pixel) is 2.84 mm² with a 0.18 μm 1-poly 4-metal CMOS image sensor process. The power consumption of the proposed single-bit CIS is 2.8 mW with a 3.3 V of supply voltage and 520 frame/s of the maximum frame rates. The error rate of the ADC is 0.24 least significant bit (LSB) on an 8-bit ADC basis at a 50 MHz sampling frequency.

  12. Process design and simulation for optimizing the oxygen concentration in Czochralski-grown single-crystal silicon

    International Nuclear Information System (INIS)

    Jung, Y. J.; Kim, W. K.; Jung, J. H.

    2014-01-01

    The highest-concentration impurity in a single-crystal silicon ingot is oxygen, which infiltrates the ingot during growth stage. This oxygen adversely affects the wafer is quality. This study was aimed at finding an optimal design for the Czochralski (Cz) process to enable high-quality and low cost (by reducing power consumption) wafer production by controlling the oxygen concentration in the silicon ingots. In the Cz process, the characteristics of silicon ingots during crystallization are greatly influenced by the design and the configuration of the hot zone, and by crystallization rate. In order to identify process conditions for obtaining an optimal oxygen concentration of 11 - 13 ppma (required for industrial-grade ingots), designed two shield shapes for the hot zone. Furthermore, oxygen concentrations corresponding to these two shapes were compared by evaluating each shape at five different production speeds. In addition, simulations were performed to identify the optimal shield design for industrial applications.

  13. Process design and simulation for optimizing the oxygen concentration in Czochralski-grown single-crystal silicon

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Y. J.; Kim, W. K.; Jung, J. H. [Yeungnam University, Gyeongsan (Korea, Republic of)

    2014-08-15

    The highest-concentration impurity in a single-crystal silicon ingot is oxygen, which infiltrates the ingot during growth stage. This oxygen adversely affects the wafer is quality. This study was aimed at finding an optimal design for the Czochralski (Cz) process to enable high-quality and low cost (by reducing power consumption) wafer production by controlling the oxygen concentration in the silicon ingots. In the Cz process, the characteristics of silicon ingots during crystallization are greatly influenced by the design and the configuration of the hot zone, and by crystallization rate. In order to identify process conditions for obtaining an optimal oxygen concentration of 11 - 13 ppma (required for industrial-grade ingots), designed two shield shapes for the hot zone. Furthermore, oxygen concentrations corresponding to these two shapes were compared by evaluating each shape at five different production speeds. In addition, simulations were performed to identify the optimal shield design for industrial applications.

  14. Design optimization of shell-and-tube heat exchangers using single objective and multiobjective particle swarm optimization

    International Nuclear Information System (INIS)

    Elsays, Mostafa A.; Naguib Aly, M; Badawi, Alya A.

    2010-01-01

    The Particle Swarm Optimization (PSO) algorithm is used to optimize the design of shell-and-tube heat exchangers and determine the optimal feasible solutions so as to eliminate trial-and-error during the design process. The design formulation takes into account the area and the total annual cost of heat exchangers as two objective functions together with operating as well as geometrical constraints. The Nonlinear Constrained Single Objective Particle Swarm Optimization (NCSOPSO) algorithm is used to minimize and find the optimal feasible solution for each of the nonlinear constrained objective functions alone, respectively. Then, a novel Nonlinear Constrained Mult-objective Particle Swarm Optimization (NCMOPSO) algorithm is used to minimize and find the Pareto optimal solutions for both of the nonlinear constrained objective functions together. The experimental results show that the two algorithms are very efficient, fast and can find the accurate optimal feasible solutions of the shell and tube heat exchangers design optimization problem. (orig.)

  15. Staff Nurse Perceptions of Open-Pod and Single Family Room NICU Designs on Work Environment and Patient Care.

    Science.gov (United States)

    Winner-Stoltz, Regina; Lengerich, Alexander; Hench, Anna Jeanine; OʼMalley, Janet; Kjelland, Kimberly; Teal, Melissa

    2018-06-01

    Neonatal intensive care units have historically been constructed as open units or multiple-bed bays, but since the 1990s, the trend has been toward single family room (SFR) units. The SFR design has been found to promote family-centered care and to improve patient outcomes and safety. The impact of the SFR design NICU on staff, however, has been mixed. The purposes of this study were to compare staff nurse perceptions of their work environments in an open-pod versus an SFR NICU and to compare staff nurse perceptions of the impact of 2 NICU designs on the care they provide for patients/families. A prospective cohort study was conducted. Questionnaires were completed at 6 months premove and again at 3, 9, and 15 months postmove. A series of 1-way analyses of variance were conducted to compare each group in each of the 8 domains. Open-ended questions were evaluated using thematic analysis. The SFR design is favorable in relation to environmental quality and control of primary workspace, privacy and interruption, unit features supporting individual work, and unit features supporting teamwork; the open-pod design is preferable in relation to walking. Incorporating design features that decrease staff isolation and walking and ensuring both patient and staff safety and security are important considerations. Further study is needed on unit design at a microlevel including headwall design and human milk mixing areas, as well as on workflow processes.

  16. All-optical Hilbert transformer based on a single phase-shifted fiber Bragg grating: design and analysis.

    Science.gov (United States)

    Asghari, Mohammad H; Azaña, José

    2009-02-01

    A simple all-fiber design for implementing an all-optical temporal Hilbert transformer is proposed and numerically demonstrated. We show that an all-optical Hilbert transformer can be implemented using a uniform-period fiber Bragg grating (FBG) with a properly designed amplitude-only grating apodization profile incorporating a single pi phase shift in the middle of the grating length. All-optical Hilbert transformers capable of processing arbitrary optical waveforms with bandwidths up to a few hundreds of gigahertz can be implemented using feasible FBGs.

  17. Mechanical design optimization of a single-axis MOEMS accelerometer based on a grating interferometry cavity for ultrahigh sensitivity

    Science.gov (United States)

    Lu, Qianbo; Bai, Jian; Wang, Kaiwei; Lou, Shuqi; Jiao, Xufen; Han, Dandan; Yang, Guoguang

    2016-08-01

    The ultrahigh static displacement-acceleration sensitivity of a mechanical sensing chip is essential primarily for an ultrasensitive accelerometer. In this paper, an optimal design to implement to a single-axis MOEMS accelerometer consisting of a grating interferometry cavity and a micromachined sensing chip is presented. The micromachined sensing chip is composed of a proof mass along with its mechanical cantilever suspension and substrate. The dimensional parameters of the sensing chip, including the length, width, thickness and position of the cantilevers are evaluated and optimized both analytically and by finite-element-method (FEM) simulation to yield an unprecedented acceleration-displacement sensitivity. Compared with one of the most sensitive single-axis MOEMS accelerometers reported in the literature, the optimal mechanical design can yield a profound sensitivity improvement with an equal footprint area, specifically, 200% improvement in displacement-acceleration sensitivity with moderate resonant frequency and dynamic range. The modified design was microfabricated, packaged with the grating interferometry cavity and tested. The experimental results demonstrate that the MOEMS accelerometer with modified design can achieve the acceleration-displacement sensitivity of about 150μm/g and acceleration sensitivity of greater than 1500V/g, which validates the effectiveness of the optimal design.

  18. Meta-Analysis of Incremental Rehearsal Using Phi Coefficients to Compare Single-Case and Group Designs

    Science.gov (United States)

    Burns, Matthew K.; Zaslofsky, Anne F.; Kanive, Rebecca; Parker, David C.

    2012-01-01

    The current study meta-analyzed single-case design (SCD) and group research regarding incremental rehearsal (IR). We used phi to meta-analyze data from 19 IR studies. Data from the SCD studies resulted in a nonoverlap of all pairs (NAP) score of 98.9% (95% CI = 97.6-100%), which resulted in a weighted phi of 0.77 (95% CI = 0.69-0.83). The group…

  19. Single-mode optical fiber design with wide-band ultra low bending-loss for FTTH application.

    Science.gov (United States)

    Watekar, Pramod R; Ju, Seongmin; Han, Won-Taek

    2008-01-21

    We propose a new design of a single-mode optical fiber (SMF) which exhibits ultra low bend sensitivity over a wide communication band (1.3 microm to 1.65 microm). A five-cladding fiber structure has been proposed to minimize the bending loss, estimated to be as low as 4.4x10(-10) dB/turn for the bend radius of 10 mm.

  20. Advanced Propfan Engine Technology (APET) definition study, single and counter-rotation gearbox/pitch change mechanism design

    Science.gov (United States)

    Anderson, R. D.

    1985-01-01

    Single-rotation propfan-powered regional transport aircraft were studied to identify key technology development issues and programs. The need for improved thrust specific fuel consumption to reduce fuel burned and aircraft direct operating cost is the dominant factor. Typical cycle trends for minimizing fuel consumption are reviewed, and two 10,000 shp class engine configurations for propfan propulsion systems for the 1990's are presented. Recommended engine configurations are both three-spool design with dual spool compressors and free power turbines. The benefits of these new propulsion system concepts were evaluated using an advanced airframe, and results are compared for single-rotation propfan and turbofan advanced technology propulsion systems. The single-rotation gearbox is compared to a similar design with current technology to establish the benefits of the advanced gearbox technology. The conceptual design of the advanced pitch change mechanism identified a high pressure hydraulic system that is superior to the other contenders and completely external to the gearboxes.

  1. The effect of shoe design and lateral wedges on knee load and neuromuscular control in healthy subjects during walking

    DEFF Research Database (Denmark)

    Mølgaard, Carsten; Kersting, Uwe G.

    2014-01-01

    The increasing number of patients with developing osteoarthritis is accompanied by a growing scientific interest in non-operative early treatment strategies. It is generally believed that laterally wedged insoles can change the distribution of knee loading. However, the importance of footwear...... wedging is effective regardless of shoe design. Differences between the three neutral walking conditions underline the importance of footwear choice in individuals. It is safe to apply lateral wedges without jeopardising muscular control during walking regardless of shoe type. Possible effects of altering...

  2. The facial and subjective emotional reaction in response to a video game designed to train emotional regulation (Playmancer).

    Science.gov (United States)

    Claes, Laurence; Jiménez-Murcia, Susana; Santamaría, Juan J; Moussa, Maher B; Sánchez, Isabel; Forcano, Laura; Magnenat-Thalmann, Nadia; Konstantas, Dimitri; Overby, Mikkel L; Nielsen, Jeppe; Bults, Richard G A; Granero, Roser; Lam, Tony; Kalapanidas, Elias; Treasure, Janet; Fernández-Aranda, Fernando

    2012-11-01

    Several aspects of social and emotional functioning are abnormal in people with eating disorders. The aim of the present study was to measure facial emotional expression in patients with eating disorders and healthy controls whilst playing a therapeutic video game (Playmancer) designed to train individuals in emotional regulation. Participants were 23 ED patients (11 AN, 12 BN) and 11 HCs. ED patients self reported more anger at baseline but expressed less facial expression of anger during the Playmancer game. The discrepancy between self-report and non-verbal expression may lead to problems in social communication. Copyright © 2012 John Wiley & Sons, Ltd and Eating Disorders Association.

  3. Design model for bending vibrations of single-stage tunnel fan rotor

    Science.gov (United States)

    Krasyuk, AM; Kosykh, PV

    2018-03-01

    Using of one-mass model of tunnel fan rotor is justified for estimation calculation of the natural bending vibrations frequency during the design stage. It’s shown that the evaluative computation of the main axial tunnel fan at the early design stage yields the acceptable accuracy. It is shown that after completion of the design, the mass of the stepped-type shaft differs from the mass of the calculated uniform-diameter shaft no more than by 40%. Inclusion of this additional mass in the estimation calculation makes it possible to improve the calculation accuracy. The region of the dimensionless rotor design parameters at which the relative difference of frequency in the evaluative and verification calculations is not higher than 5 % is determined.

  4. Design optimization of single-main-amplifier KrF laser-fusion systems

    International Nuclear Information System (INIS)

    Harris, D.B.; Pendergrass, J.H.

    1985-01-01

    KrF lasers appear to be a very promising laser fusion driver for commercial applications. The Large Amplifier Module for the Aurora Laser System at Los Alamos is the largest KrF laser in the world and is currently operating at 5 kJ with 10 to 15 kJ eventually expected. The next generation system is anticipated to be a single-main-amplifier system that generates approximately 100 kJ. This paper examines the cost and efficiency tradeoffs for a complete single-main-amplifier KrF laser fusion experimental facility. It has been found that a 7% efficient $310/joule complete laser-fusion system is possible by using large amplifier modules and high optical fluences

  5. Computer Aided Design of Ni-Based Single Crystal Superalloy for Industrial Gas Turbine Blades

    Science.gov (United States)

    Wei, Xianping; Gong, Xiufang; Yang, Gongxian; Wang, Haiwei; Li, Haisong; Chen, Xueda; Gao, Zhenhuan; Xu, Yongfeng; Yang, Ming

    The influence of molybdenum, tungsten and cobalt on stress-rupture properties of single crystal superalloy PWA1483 has been investigated using the simulated calculation of JMatPro software which ha s been widely used to develop single crystal superalloy, and the effect of alloying element on the stability of strengthening phase has been revealed by using the Thermo-Calc software. Those properties calculation results showed that the increasing of alloy content could facilitate the precipitation of TCP phases and increase the lattice misfit between γ and γ' phase, and the effect of molybdenum, tantalum was the strongest and that of cobalt was the weakest. Then the chemical composition was optimized, and the selected compositions showed excellent microstructure stability and stress-rupture properties by the confirmation of d-electrons concept and software calculation.

  6. Improved Design Methods for Robust Single- and Three-Phase ac-dc-ac Power Converters

    DEFF Research Database (Denmark)

    Qin, Zian

    . The approaches for improving their performance, in terms of the voltage stress, efficiency, power density, cost, loss distribution, and temperature, will be studied. The structure of the thesis is as follows, Chapter 1 presents the introduction and motivation of the whole project as well as the background...... becomes a emerging challenge. Accordingly, installation of sustainable power generators like wind turbines and solar panels has experienced a large increase during the last decades. Meanwhile, power electronics converters, as interfaces in electrical system, are delivering approximately 80 % electricity...... back-to-back, and meanwhile improve the harmonics, control flexibility, and thermal distribution between the switches. Afterwards, active power decoupling methods for single-phase inverters or rectifiers that are similar to the single-phase ac-dc-ac converter, are studied in Chapter 4...

  7. Design and analysis of single- ended robust low power 8T SRAM cell

    Directory of Open Access Journals (Sweden)

    Gupta Neha

    2016-01-01

    Full Text Available This paper is based on the observation of 8T single ended static random access memory (SRAM and two techniques for reducing the sub threshold leakage current, power consumption are examined. In the first technique, effective supply voltage and ground node voltages are changed using a dynamic variable voltage level technique(VVL. In the second technique power supply is scaled down. This 8T SRAM cell uses one word line, two bitlinesand a transmission gate. Simulations and analytical results show that when the two techniques combine the new SRAM cell has correct read and write operation and also the cell contains 55.6% less leakage and the dynamic power is 98.8% less than the 8T single ended SRAM cell. Simulations are performed using cadence virtuoso tool at 45nm technology.

  8. Experimental design rules for implementing biconically tapered single mode optical fibre displacement sensors

    Science.gov (United States)

    Arregui, Francisco J.; Matias, Ignacio R.; Bariain, Candido; Lopez-Amo, Manuel

    1998-06-01

    Tapered optical fibers are used to design couplers, wavelength division multiplexers, near field scanning optical microscopy, just to mention a few. Moreover, and due to its strong transmission dependence to external medium the tapered fiber may also be used to sense distinct parameters such as temperature, humidity, PH, etc. In this work bending effects in tapers are exploited to achieved displacement sensors and to present design rules for implementing these sensors according to the desired both range and sensitivity.

  9. Multi-kW single fiber laser based on an extra large mode area fiber design

    Science.gov (United States)

    Langner, Andreas; Such, Mario; Schötz, Gerhard; Just, Florian; Leich, Martin; Schwuchow, Anka; Grimm, Stephan; Zimer, Hagen; Kozak, Marcin; Wedel, Björn; Rehmann, Georg; Bachert, Charley; Krause, Volker

    2012-02-01

    The quality of Yb-doped fused bulk silica produced by sintering of Yb-doped fused silica granulates has improved greatly in the past five years [1 - 4]. In particular, the refractive index and doping level homogeneity of such materials are excellent and we achieved excellent background fiber attenuation of the active core material down to about 20 dB/km at 1200 nm. The improvement of the Yb-doped fused bulk silica has enabled the development of multi-kW fiber laser systems based on a single extra large multimode laser fiber (XLMA fiber). When a single active fiber is used in combination with the XLMA multimode fiber of 1200 μm diameter simple and robust high power fiber laser setups without complex fiber coupling and fiber combiner systems become possible. In this papper, we will discuss in detail the development of the core material based on Yb-doped bulk silica and the characterization of Yb-doped fibers with different core compositions. We will also report on the excellent performance of a 4 kW fiber laser based on a single XLMA-fiber and show the first experimental welding results of steel sheets achieved with such a laser.

  10. Strain measurement of objects subjected to aerodynamic heating using digital image correlation: experimental design and preliminary results.

    Science.gov (United States)

    Pan, Bing; Jiang, Tianyun; Wu, Dafang

    2014-11-01

    In thermomechanical testing of hypersonic materials and structures, direct observation and quantitative strain measurement of the front surface of a test specimen directly exposed to severe aerodynamic heating has been considered as a very challenging task. In this work, a novel quartz infrared heating device with an observation window is designed to reproduce the transient thermal environment experienced by hypersonic vehicles. The specially designed experimental system allows the capture of test article's surface images at various temperatures using an optical system outfitted with a bandpass filter. The captured images are post-processed by digital image correlation to extract full-field thermal deformation. To verify the viability and accuracy of the established system, thermal strains of a chromiumnickel austenite stainless steel sample heated from room temperature up to 600 °C were determined. The preliminary results indicate that the air disturbance between the camera and the specimen due to heat haze induces apparent distortions in the recorded images and large errors in the measured strains, but the average values of the measured strains are accurate enough. Limitations and further improvements of the proposed technique are discussed.

  11. Progress towards developing consistent design and evaluation guidelines for US Department of Energy facilities subjected to natural phenomena

    International Nuclear Information System (INIS)

    Murray, R.C.

    1987-01-01

    Probabilistic definitions of earthquake, wind, and tornado hazards for many DOE facilities throughout the United States have been developed. In addition, definitions of the flood hazards which might affect these locations are currently being developed. We have prepared a document to provide guidance and criteria for DOE facility managers to assure that DOE facilities are adequately constructed to resist the effects of natural phenomena such as earthquake, strong wind, and flood. The intent of this document is to provide instruction on how to utilize the hazard definitions to evaluate existing facilities and design new facilities in a manner such that the risk of adverse consequences is consistent with the cost, function, and danger to the public or environment. A conference and six mini-courses were organized on natural phenomena hazards mitigation. This provided a mechanism for technology transfer to the DOE community. Complementary manuals have also been developed for 1) suspended ceiling systems and recommendations for bracing them, 2) practical equipment seismic upgrade and strengthening guidelines, and 3) suggested structural details for wind design. These manuals are intended to provide input and guidance for ongoing site safety programs. (orig./HP)

  12. Emollient product design: objective measurements of formulation structure, texture and performance, and subjective assessments of user acceptability.

    Science.gov (United States)

    Antonijević, M D; Owusu-Ware, S; Sanchon-Lopez, B

    2018-06-01

    The choice of prescribed emollients is usually based on cost and patient preference. Differences in formulations can affect user acceptability. To compare the physical performance, user acceptability and various product design features of two emollient gels that are prescribed in the UK and alleged to be therapeutically interchangeable because their formulations are described as having the same contents of oily ingredients. We found that here are in fact significant measurable differences between the structure and performance of the two formulations, which materially affect their user acceptability. These differences are attributed to the use of different types of gelling agents and other ingredients of differing grades/quality and concentrations, and probably due to the formulations being made by different manufacturing processes. We also identified other product design features that are important to user appeal, including the type of container in which the formulations are presented, the type of dispensing devices provided, and the nature and form of the supplied user instructions. Patients and prescribers should be aware that there can be important differences in performance and user appeal between emollients, even between products that, superficially, may appear to be very similar. These important performance aspects should be characterized for new emollient introductions to encourage better informed product selection. © 2018 The Authors. Clinical and Experimental Dermatology published by John Wiley & Sons Ltd on behalf of British Association of Dermatologists, North American Clinical Dermatologic Society and St Johns Dermatological Society.

  13. Progress towards developing consistent design and evaluation guidelines for US Department of Energy facilities subjected to natural phenomena

    International Nuclear Information System (INIS)

    Murray, R.C.

    1987-01-01

    Probabilistic definitions of earthquake, wind, and tornado hazards for many Department of Energy (DOE) facilities throughout the United States have been developed. In addition, definitions of the flood hazards which might affect these locations are currently being developed. The authors have prepared a document to provide guidance and criteria for DOE facility managers to assure that DOE facilities are adequately constructed to resist the effects of natural phenomena such as earthquake, strong wind, and flood. The intent of this document is to provide instruction on how to utilize the hazard definitions to evaluate existing facilities and design new facilities in a manner such that the risk of adverse consequences is consistent with the cost, function, and danger to the public or environment. A conference and six mini-courses were organized on natural phenomena hazards mitigation. This provided a mechanism for technology transfer to the DOE community. Complementary manuals have also been developed for 1) suspended ceiling systems and recommendations for bracing them, 2) practical equipment seismic upgrade and strengthening guidelines, and 3) suggested structural details for wind design. These manuals are intended to provide input and guidance for ongoing site safety programs

  14. A single-dose, crossover, placebo- and moxifloxacin-controlled study to assess the effects of neratinib (HKI-272) on cardiac repolarization in healthy adult subjects.

    Science.gov (United States)

    Hug, Bruce; Abbas, Richat; Leister, Cathie; Burns, Jaime; Sonnichsen, Daryl

    2010-08-01

    Neratinib is an orally administered, small-molecule, irreversible pan-ErbB inhibitor in development for the treatment of ErbB2-positive breast cancer. This study assessed the effects of therapeutic and supratherapeutic neratinib concentrations on cardiac repolarization, in accordance with current regulatory guidance. This was a two-part study in healthy subjects. In part 1, subjects were randomized to receive placebo, 400 mg moxifloxacin, or 240 mg neratinib (therapeutic dose) following a high-fat meal. In part 2, after a washout period, subjects received placebo plus 400 mg ketoconazole or 240 mg neratinib plus ketoconazole (supratherapeutic dose). ANOVA was used to compare the baseline-adjusted QTc interval for neratinib with that of placebo (reference), and for neratinib plus ketoconazole with that of placebo plus ketoconazole (reference). Pharmacokinetic/pharmacodynamic analyses and categorical summaries of interval data were done. Assay sensitivity was evaluated by the effect of moxifloxacin on QTc compared with placebo. Sixty healthy subjects were enrolled in this study. The upper bounds of the 90% confidence interval for baseline-adjusted QTcN (population-specific corrected QT) were neratinib. Pharmacokinetic/pharmacodynamic analysis revealed no relationship between neratinib concentrations and QTc interval. No subjects had QTcI, QTcF, or QTcN intervals >450 milliseconds or change from baseline >30 milliseconds. Moxifloxacin produced a significant increase in QTcN compared with placebo (P neratinib do not prolong the QTc interval in healthy subjects. (c) 2010 AACR.

  15. Generation of subject-specific, dynamic, multisegment ankle and foot models to improve orthotic design: a feasibility study

    Directory of Open Access Journals (Sweden)

    Oosterwaal Michiel

    2011-11-01

    Full Text Available Abstract Background Currently, custom foot and ankle orthosis prescription and design tend to be based on traditional techniques, which can result in devices which vary greatly between clinicians and repeat prescription. The use of computational models of the foot may give further insight in the biomechanical effects of these devices and allow a more standardised approach to be taken to their design, however due to the complexity of the foot the models must be highly detailed and dynamic. Methods/Design Functional and anatomical datasets will be collected in a multicentre study from 10 healthy participants and 15 patients requiring orthotic devices. The patient group will include individuals with metarsalgia, flexible flat foot and drop foot. Each participant will undergo a clinical foot function assessment, 3D surface scans of the foot under different loading conditions, and detailed gait analysis including kinematic, kinetic, muscle activity and plantar pressure measurements in both barefoot and shod conditions. Following this each participant will undergo computed tomography (CT imaging of their foot and ankle under a range of loads and positions while plantar pressures are recorded. A further subgroup of participants will undergo magnetic resonance imaging (MRI of the foot and ankle. Imaging data will be segmented to derive the geometry of the bones and the orientation of the joint axes. Insertion points of muscles and ligaments will be determined from the MRI and CT-scans and soft tissue material properties computed from the loaded CT data in combination with the plantar pressure measurements. Gait analysis data will be used to drive the models and in combination with the 3D surface scans for scaling purposes. Predicted plantar pressures and muscle activation patterns predicted from the models will be compared to determine the validity of the models. Discussion This protocol will lead to the generation of unique datasets which will be used

  16. Development of the JNC geological disposal technical information integration system subjected for repository design and safety assessment

    International Nuclear Information System (INIS)

    Ishihara, Yoshinao; Ito, Takashi; Kobayashi, Shigeki; Neyama, Atsushi

    2004-02-01

    On this work, system manufacture about disposal technology and safety assessment field was performed towards construction of the JNC Geological Disposal Technical Information Integration System which systematized three fields of technical information acquired in investigation (site characteristic investigation) of geology environmental conditions, disposal technology (design of deep repository), and performance/safety assessment. The technical information database managed focusing on the technical information concerning individual research of an examination, analysis, etc. and the parameter set database managed focusing on the set up data set used in case of comprehensive evaluation are examined. In order to support and promote share and use of the technical information registered and managed by the database, utility functions, such as a technical information registration function, technical information search/browse function, analysis support function, and visualization function, are considered, and the system realized in these functions is built. The built system is installed in the server of JNC, and the functional check examination is carried out. (author)

  17. Mechanical design of a single-axis monolithic accelerometer for advanced seismic attenuation systems

    Energy Technology Data Exchange (ETDEWEB)

    Bertolini, Alessandro [Dipartimento di Fisica dell' Universita di Pisa and INFM, Largo Pontecorvo 2, I-56127 Pisa (Italy) and LIGO Project, California Institute of Technology, 1200 E. California Blvd., Pasadena, CA 91125 (United States)]. E-mail: alessandro.bertolini@desy.de; DeSalvo, Riccardo [LIGO Project, California Institute of Technology, 1200 E. California Blvd., Pasadena, CA 91125 (United States); Fidecaro, Francesco [Dipartimento di Fisica dell' Universita di Pisa and INFM, Largo Pontecorvo 2, I-56127 Pisa (Italy); Francesconi, Mario [Dipartimento di Fisica dell' Universita di Pisa and INFM, Largo Pontecorvo 2, I-56127 Pisa (Italy); Marka, Szabolcs [Department of Physics, Columbia University, 538 W. 120th St., New York, NY 10027 (United States); Sannibale, Virginio [LIGO Project, California Institute of Technology, 1200 E. California Blvd., Pasadena, CA 91125 (United States); Simonetti, Duccio [Dipartimento di Fisica dell' Universita di Pisa and INFM, Largo Pontecorvo 2, I-56127 Pisa (Italy); Takamori, Akiteru [LIGO Project, California Institute of Technology, 1200 E. California Blvd., Pasadena, CA 91125 (United States); Earthquake Research Institute, University of Tokyo, 1-1-1 Yayoi, Bunkyo-Ku, Tokyo 113-0032 (Japan); Tariq, Hareem [LIGO Project, California Institute of Technology, 1200 E. California Blvd., Pasadena, CA 91125 (United States)

    2006-01-15

    The design and mechanics for a new very-low noise low frequency horizontal accelerometer is presented. The sensor has been designed to be integrated in an advanced seismic isolation system for interferometric gravitational wave detectors. The motion of a small monolithic folded-pendulum (FP) is monitored by a high resolution capacitance displacement sensor; a feedback force actuator keeps the mass at the equilibrium position. The feedback signal is proportional to the ground acceleration in the frequency range 0-150Hz. The very high mechanical quality factor, Q{approx}3000 at a resonant frequency of 0.5Hz, reduces the Brownian motion of the proof mass of the accelerometer below the resolution of the displacement sensor. This scheme enables the accelerometer to detect the inertial displacement of a platform with a root-mean-square noise less than 1nm, integrated over the frequency band from 0.01 to 150Hz. The FP geometry, combined with the monolithic design, allows the accelerometer to be extremely directional. A vertical-horizontal coupling ranging better than 10{sup -3} has been achieved. A detailed account of the design and construction of the accelerometer is reported here. The instrument is fully ultra-high vacuum compatible and has been tested and approved for integration in seismic attenuation system of japanese TAMA 300 gravitational wave detector. The monolithic design also makes the accelerometer suitable for cryogenic operation.

  18. Design of single-layer high-efficiency transmitting phase-gradient metasurface and high gain antenna

    Science.gov (United States)

    Zhang, Di; Yang, Xiaoqing; Su, Piqiang; Luo, Jiefang; Chen, Huijie; Yuan, Jianping; Li, Lixin

    2017-12-01

    In this paper, based on rotation phase-gradient principle, a single-layer, high-efficiency transmitting metasurface is designed and applied to high-gain antenna. In the case of circularly polarized incident wave, the PCR (polarization conversions ratio) of the metasurface element is greater than 90% in the band of 9.11-10.48 GHz. The transmitting wave emerges an anomalous refraction when left-handed circularly polarized wave are incident perpendicularly to the 1D phase-gradient metasurface, which is composed of cycle arrangement of 6 units with step value of 30°. The simulated anomalous refraction angle is 40.1°, coincided with the theoretical design value (40.6°). For further application, the 2D focused metasurface is designed to enhance the antenna performance while the left-handed circularly polarized antenna is placed at the focus. The simulated max gain is increased by 12 dB (182%) and the half-power beamwidth is reduced by 74.6°. The measured results are coincided with the simulations, which indicates the antenna has high directivity. The designed single-layer transmission metasurface has advantages of thin thickness (only 1.5 mm), high efficiency and light weight, and will have important application prospects in polarization conversion and beam control.

  19. Detecting and locating light atoms from high-resolution STEM images: The quest for a single optimal design

    Energy Technology Data Exchange (ETDEWEB)

    Gonnissen, J.; De Backer, A. [Electron Microscopy for Materials Science (EMAT), University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium); Dekker, A.J. den [iMinds-Vision Lab, University of Antwerp, Universiteitsplein 1, 2610 Wilrijk (Belgium); Delft Center for Systems and Control (DCSC), Delft University of Technology, Mekelweg 2, 2628 CD Delft (Netherlands); Sijbers, J. [iMinds-Vision Lab, University of Antwerp, Universiteitsplein 1, 2610 Wilrijk (Belgium); Van Aert, S., E-mail: sandra.vanaert@uantwerpen.be [Electron Microscopy for Materials Science (EMAT), University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium)

    2016-11-15

    In the present paper, the optimal detector design is investigated for both detecting and locating light atoms from high resolution scanning transmission electron microscopy (HR STEM) images. The principles of detection theory are used to quantify the probability of error for the detection of light atoms from HR STEM images. To determine the optimal experiment design for locating light atoms, use is made of the so-called Cramér–Rao Lower Bound (CRLB). It is investigated if a single optimal design can be found for both the detection and location problem of light atoms. Furthermore, the incoming electron dose is optimised for both research goals and it is shown that picometre range precision is feasible for the estimation of the atom positions when using an appropriate incoming electron dose under the optimal detector settings to detect light atoms. - Highlights: • The optimal detector design to detect and locate light atoms in HR STEM is derived. • The probability of error is quantified and used to detect light atoms. • The Cramér–Rao lower bound is calculated to determine the atomic column precision. • Both measures are evaluated and result in the single optimal LAADF detector regime. • The incoming electron dose is optimised for both research goals.

  20. Marginal bone levels at single tooth implants with a conical fixture design. The influence of surface macro- and microstructure.

    Science.gov (United States)

    Norton, M R

    1998-04-01

    The concept of a conical implant design to accommodate single tooth replacement, has previously been shown to result in excessive bone loss, around the machined titanium conical collar, usually down to the 1st thread. This unusually aggressive loss of bone was shown to occur within a short period of time, post loading, with greater than 3 mm of bone loss occurring within the 1st 6 months to 1 year. The influence of implant design, surface texture and microleakage have all been highlighted as a potential cause. A modification of the surface structure, both at the macroscopic and microscopic level, as well as an altered fixture-abutment interface design has resulted in the maintenance of marginal bone around a single tooth titanium implant with a similar conical design. The radiographic follow-up of 33 implants loaded for up to 4 years, has revealed, by comparison, a most favourable maintenance of marginal bone around the conical collar, with a mean marginal bone loss of 0.32 mm mesially and 0.34 mm distally for the whole group. The cumulative mean marginal bone loss mesially and distally is 0.42 mm and 0.40 mm from 1 to 2 years, 0.54 mm and 0.43 mm from 2 to 3 years, 0.51 mm and 0.24 mm from 3 to 4 years, and 0.62 mm and 0.60 mm for implants past their 4 year recall.

  1. A room of one's own--Being cared for in a hospital with a single-bed room design.

    Science.gov (United States)

    Persson, Eva; Anderberg, Patrice; Ekwall, Anna Kristensson

    2015-06-01

    To illuminate patients' experiences of being hospitalised in a hospital with a single-bed room design. Many patients seem to prefer single-bed hospital rooms. However, studies have also shown that patients do see the advantages of multiple-bed rooms. Interviews were conducted with 16 inpatients from a surgical ward in a hospital building with a single-bed room design. A hermeneutical-phenomenological approach guided by van Manen's four life-world existentials was used to analyse the interviews. The essential meaning was that patients felt secure because they could create a personal environment without disruptive elements. The room was private, and this implied feelings of homeliness, which allowed patients to focus on themselves and was thought to facilitate the recovery process. The patients preferred staying in their room, and the relationship with the personnel was central. Feelings of loneliness and isolation could occur and could be frightening. Being hospitalised in a single-bed room meant balancing between feeling secure and feeling insecure. The following four themes emerged: A homely environment, The need for company and security, Time as unpredictable and involving waiting and Focus on healing the body. Patients experienced that a single-bed room allowed them to focus on their recovery, have visitors without disturbing others and create a feeling of homeliness. However, mobilisation is not a natural part of the recovery process when patients have all they need in their rooms. The patients' need for social interaction and confirmation was not satisfied without effort and planning on the part of staff. © 2014 Nordic College of Caring Science.

  2. Design and Research of Intelligent Remote Control Fan Based on Single Chip Microcomputer and Bluetooth Technology

    Directory of Open Access Journals (Sweden)

    Zhang Xue-Xia

    2017-01-01

    Full Text Available This paper is designed for intelligent remote control fans. The design of the microcontroller as the core, the sensor, Bluetooth and Andrews system applied to the design of intelligent remote control fan. According to the temperature sensor to achieve the indoor temperature collection, to achieve and set the temperature comparison, thus affecting the fan speed. At the same time, the system according to the infrared sensor components to detect external factors, in order to achieve the running or stopping of the fan, that is, to achieve intelligent control of the fan. In addition, the system achieve the Bluetooth and mobile phone Andrews system of effective combination, and through the software program to complete the fan remote operation and wind speed control.

  3. SSC 50 MM collider dipole cryostat single tube support post conceptual design and analysis

    International Nuclear Information System (INIS)

    Nicol, T.H.

    1992-01-01

    Superconducting Super Collider (SSC) dipole magnet cold masses are connected to the cryostat vacuum vessel at five places equally spaced along their length. Five supports limit sag of the cold assembly due to its own weight to a level consistent with the final magnet alignment specifications. The design essentially consists of two composite tubes nested within each other as a means of maximizing the thermal path length. In addition it provides an ideal way to utilize materials best suited for the temperature range over which they must operate. Filament wound S-glass is used between 300K and 80K. Filament wound graphite fiber is used between 80K and 20K and between 20K and 4.5K. S-glass is a better thermal performer above approximately 40K. Graphite composites are ideally suited for operation below 40K. The designs for the 50 mm reentrant supports are well documented in the literature. The current design of the reentrant support has two major drawbacks. First, it requires very tight dimensional control on all components; composite tubes and metal attachment parts. Second, it is expensive, with cost being driven by both the tolerance constraints and by a complex assembly procedure. It seems clear that production magnets will require a support structure which is considerably less expensive than that which is currently used. It seems clear that a design alternate for reentrant support posts will be required for production dipoles primarily due to their cost. It seems less clear that injection molded composite materials are the ideal choice. This report describes the conceptual design for a support post whose function is identical to that of the current reentrant design, which requires very few modifications to surrounding cryostat components, is thermally equivalent to the current 50 mm support post, and is nearly equivalent structurally

  4. Design of a Negative Differential Resistance Circuit Element Using Single-Electron Transistors

    Science.gov (United States)

    Dixon, D. C.; Heij, C. P.; Hadley, P.; Mooij, J. E.

    1998-03-01

    Electronic circuit elements displaying negative differential resistance (NDR), such as tunnel diodes, have a wide variety of device applications, including oscillators, amplifiers, logic, and memory. We present a two-terminal device using two single-electron transistors (SET's) that demonstrates an NDR profile tuneable with gate voltages. If the capacitive coupling between the SET's is sufficiently larger than the junction capacitances, the device exhibits multiply-peaked NDR, allowing its use as a multi-valued digital element. We will also report recent experimental progress in measurements of such a device, fabricated using standard Al tunnel junctions, but with an additional overlap capacitor to allow the required inter-SET coupling.

  5. Single Allocation Hub-and-spoke Networks Design Based on Ant Colony Optimization Algorithm

    Directory of Open Access Journals (Sweden)

    Yang Pingle

    2014-10-01

    Full Text Available Capacitated single allocation hub-and-spoke networks can be abstracted as a mixed integer linear programming model equation with three variables. Introducing an improved ant colony algorithm, which has six local search operators. Meanwhile, introducing the "Solution Pair" concept to decompose and optimize the composition of the problem, the problem can become more specific and effectively meet the premise and advantages of using ant colony algorithm. Finally, location simulation experiment is made according to Australia Post data to demonstrate this algorithm has good efficiency and stability for solving this problem.

  6. Design of L1 -Adaptive Controller for Single Axis Positioning Table

    Directory of Open Access Journals (Sweden)

    Amjad Jalil Humaidi

    2017-11-01

    Full Text Available L1 adaptive controller has proven to provide fast adaptation with guaranteed transients in a large variety of systems. It is commonly used for controlling systems with uncertain time-varying unknown parameters. The effectiveness of L1 adaptive controller for position control of single axis has been examined and compared with Model Reference Adaptive Controller (MRAC. The Linear servo motor is one of the main constituting elements of the x-y table which is mostly used in automation application. It is characterized by time-varying friction and disturbance

  7. Precision Attitude Determination System (PADS) system design and analysis: Single-axis gimbal star tracker

    Science.gov (United States)

    1974-01-01

    The feasibility is evaluated of an evolutionary development for use of a single-axis gimbal star tracker from prior two-axis gimbal star tracker based system applications. Detailed evaluation of the star tracker gimbal encoder is considered. A brief system description is given including the aspects of tracker evolution and encoder evaluation. System analysis includes evaluation of star availability and mounting constraints for the geosynchronous orbit application, and a covariance simulation analysis to evaluate performance potential. Star availability and covariance analysis digital computer programs are included.

  8. Detecting and locating light atoms from high-resolution STEM images: The quest for a single optimal design.

    Science.gov (United States)

    Gonnissen, J; De Backer, A; den Dekker, A J; Sijbers, J; Van Aert, S

    2016-11-01

    In the present paper, the optimal detector design is investigated for both detecting and locating light atoms from high resolution scanning transmission electron microscopy (HR STEM) images. The principles of detection theory are used to quantify the probability of error for the detection of light atoms from HR STEM images. To determine the optimal experiment design for locating light atoms, use is made of the so-called Cramér-Rao Lower Bound (CRLB). It is investigated if a single optimal design can be found for both the detection and location problem of light atoms. Furthermore, the incoming electron dose is optimised for both research goals and it is shown that picometre range precision is feasible for the estimation of the atom positions when using an appropriate incoming electron dose under the optimal detector settings to detect light atoms. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Attitude Control of a Single Tilt Tri-Rotor UAV System: Dynamic Modeling and Each Channel's Nonlinear Controllers Design

    Directory of Open Access Journals (Sweden)

    Juing-Shian Chiou

    2013-01-01

    Full Text Available This paper has implemented nonlinear control strategy for the single tilt tri-rotor aerial robot. Based on Newton-Euler’s laws, the linear and nonlinear mathematical models of tri-rotor UAVs are obtained. A numerical analysis using Newton-Raphson method is chosen for finding hovering equilibrium point. Back-stepping nonlinear controller design is based on constructing Lyapunov candidate function for closed-loop system. By imitating the linguistic logic of human thought, fuzzy logic controllers (FLCs are designed based on control rules and membership functions, which are much less rigid than the calculations computers generally perform. Effectiveness of the controllers design scheme is shown through nonlinear simulation model on each channel.

  10. SSD for R: A Comprehensive Statistical Package to Analyze Single-System Data

    Science.gov (United States)

    Auerbach, Charles; Schudrich, Wendy Zeitlin

    2013-01-01

    The need for statistical analysis in single-subject designs presents a challenge, as analytical methods that are applied to group comparison studies are often not appropriate in single-subject research. "SSD for R" is a robust set of statistical functions with wide applicability to single-subject research. It is a comprehensive package…

  11. Modified Design of Anterolateral Thigh Flap for Total Pharyngolaryngectomy Reconstruction: A Single-Center Experience.

    Science.gov (United States)

    Cheng, Li-Yen; Chen, Cha-Chun; Lin, Hwang-Chi; Jeng, Chu-Hsu; Lin, Shang-Hsi; Chen, Wei-Nung Jim; Lin, Yu-Hsien; Hao, Sheng-Po

    2018-07-01

    Defects after total pharyngolaryngectomy for hypopharyngeal cancer often require reconstruction via free tissue transfer. Recently, anterolateral thigh (ALT) flap has become the gold standard in many centers because of its advantages with respect to versatility, minimal donor-site morbidity, good speech quality, and relatively low fistula and anastomotic leakage rates. Moreover, ALT allows 2 surgical teams to work simultaneously. However, the height of the parallelogram in the ALT design for neoesophagus reconstruction is usually set at a minimum of 9.4 cm (circumference, 2πr) for smooth food passage. Because this height exceeds 8 cm, the donor site may not be closed primarily, which highly depends on the patient's body habitus and the skin tone or quality and requires other methods, such as local flap or skin graft for wound closure, which subsequently increase operating time and donor-site complication rate. Thus, we aimed to construct a simple and modified ALT design that will not only include the advantages described earlier but also provide adequate donor-site primary closure without jeopardizing complication rates. Ten patients with hypopharyngeal cancer underwent reconstructive surgery using our modified ALT design after total pharyngolaryngectomy between 2010 and 2017. Our modified ALT design converts this "classical" shape into a parallelogram so that the height of the modified design is always less than 8 cm, thus allowing for easy primary closure of the wound. The donor-site defects of all 10 patients were closed primarily. No donor-site complications and partial or total flap loss were observed. One patient experienced persistent wound infection with dehiscence, for which debridement was performed. The stricture and fistula rates were 10% (n = 1) and 20% (n = 2), respectively. The mean follow-up time is approximately 1 year. Minimizing donor-site morbidity is an important goal in reconstructive surgery. Our modified ALT flap design is simple, enabling

  12. Design of Controller for Reducing In-Rush Current of Single-Phase Induction Motor

    Energy Technology Data Exchange (ETDEWEB)

    Park, Su Kang; Baek, Hyung Lae; Lee, Sang Il [Chosun University, Kwangju (Korea)

    2001-05-01

    During an AC motor's start-up accelerating period, a large amount of current is required to reach to the rating speed. This is called in-rush current. This peak in-rush current can be more than about several times the operating or steady-state current in the full load rating of the motor. In-rush current is present in both and electronic ballasts. The main area of concern is the tripping of circuit breaker and fuses which can affect electrical system components From this, we can see that the electrical power controllers will be rather concerned, since they have to supply the actual current necessary to start the motor. This paper presents a new method to reducing in-rush current and energy saving of the single-phase induction motor used in air-conditioner. It can be obtained that proposed system is low cost and small size as compared with other controller. Experiments are focused on a capacitor starting single-phase induction motor. The optimal power saving and in-rush current limiting by phase angle control are verified by experimental results. Also, auxiliary winding was controlled by electronic starting switch. (author). 10 refs., 13 figs., 2 tabs.

  13. Design of high-activity single-atom catalysts via n-p codoping

    Science.gov (United States)

    Wang, Xiaonan; Zhou, Haiyan; Zhang, Xiaoyang; Jia, Jianfeng; Wu, Haishun

    2018-03-01

    The large-scale synthesis of stable single-atom catalysts (SACs) in experiments remains a significant challenge due to high surface free energy of metal atom. Here, we propose a concise n-p codoping approach, and find it can not only disperse the relatively inexpensive metal, copper (Cu), onto boron (B)-doped graphene, but also result in high-activity SACs. We use CO oxidation on B/Cu codoped graphene as a prototype example, and demonstrate that: (1) a stable SAC can be formed by stronger electrostatic attraction between the metal atom (n-type Cu) and support (p-type B-doped graphene). (2) the energy barrier of the prototype CO oxidation on B/Cu codoped graphene is 0.536 eV by the Eley-Rideal mechanism. Further analysis shows that the spin selection rule can provide well theoretical insight into high activity of our suggested SAC. The concept of n-p codoping may lead to new strategy in large-scale synthesis of stable single-atom catalysts.

  14. Design of a Modular DNA Triangular-Prism Sensor Enabling Ratiometric and Multiplexed Biomolecule Detection on a Single Microbead.

    Science.gov (United States)

    Liu, Yu; Chen, Qiaoshu; Liu, Jianbo; Yang, Xiaohai; Guo, Qiuping; Li, Li; Liu, Wei; Wang, Kemin

    2017-03-21

    DNA nanostructures have emerged as powerful and versatile building blocks for the construction of programmable nanoscale structures and functional sensors for biomarker detection, disease diagnostics, and therapy. Here we integrated multiple sensing modules into a single DNA three-dimensional (3D) nanoarchitecture with a triangular-prism (TP) structure for ratiometric and multiplexed biomolecule detection on a single microbead. In our design, the complementary hybridization of three clip sequences formed TP nanoassemblies in which the six single-strand regions in the top and bottom faces act as binding sites for different sensing modules, including an anchor module, reference sequence module, and capture sequence module. The multifunctional modular TP nanostructures were thus exploited for ratiometric and multiplexed biomolecule detection on microbeads. Microbead imaging demonstrated that, after ratiometric self-calibration analysis, the imaging deviations resulting from uneven fluorescence intensity distribution and differing probe concentrations were greatly reduced. The rigid nanostructure also conferred the TP as a framework for geometric positioning of different capture sequences. The inclusion of multiple targets led to the formation of sandwich hybridization structures that gave a readily detectable optical response at different fluorescence channels and distinct fingerprint-like pattern arrays. This approach allowed us to discriminate multiplexed biomolecule targets in a simple and efficient fashion. In this module-designed strategy, the diversity of the controlled DNA assembly coupled with the geometrically well-defined rigid nanostructures of the TP assembly provides a flexible and reliable biosensing approach that shows great promise for biomedical applications.

  15. Rotor Design for an Efficient Single-Phase Induction Motor for Refrigerator Compressors

    Directory of Open Access Journals (Sweden)

    Hyun-Jin Ahn

    2016-03-01

    Full Text Available This article describes a rotor making technology for the production of high-efficiency single-phase induction motors (SPIMs to be used in refrigerator compressors. Rotors can have different aluminum fill factors according to the fabrication method. In order to examine the association between the fill factor and the efficiency of the rotor, we analyzed the distribution of magnetic flux density using the finite element method (FEM. Next, we made prototype rotors by conventional casting methods and by the proposed casting method and compared their fill factors. In addition, SPIMs were made using the rotors, and their efficiencies were measured using a dynamometer. Moreover, the SPIMs were put to use in a compressor, for testing, and for each SPIM the refrigerating capacity of the compressor was measured with a calorimeter. Based on the results of the FEM analysis of the magnetic flux density and the experiments, the reliability and validity of the proposed method were proven.

  16. A single of MR sponge tactile sensor design for medical applications

    Science.gov (United States)

    Cha, Seung-Woo; Kang, Seok-Rae; Hwang, Yong-Hoon; Choi, Seung-Bok

    2017-04-01

    Recently, it is very popular in medical field to adopt robot surgery such as robot-assisted minimally invasive surgery (RMIS). However, there are some problems in the robot surgery. It is very hard to get the touch feeling of the organs during the surgical operation because the surgeons cannot touch and feel repulsive force from the organs directly. So, this work proposes a squeeze mode of single magneto-rheological (MR) sponge to realize viscoelastic property of human organs or skins and undertake a theoretical analysis of MR sponge. In addition, its effectiveness is verified through experimental tests. The similarity between MR sponge and real organs is identified and desired repulsive force of each organs can be achieved by proper selection of MR sponge cell associated with controlled input current.

  17. Partial PIC-MRC Receiver Design for Single Carrier Block Transmission System over Multipath Fading Channels

    Directory of Open Access Journals (Sweden)

    Juinn-Horng Deng

    2012-01-01

    Full Text Available Single carrier block transmission (SCBT system has become one of the most popular modulation systems due to its low peak-to-average power ratio (PAPR, and it is gradually considered to be used for uplink wireless communication systems. In this paper, a low complexity partial parallel interference cancellation (PIC with maximum ratio combining (MRC technology is proposed to use for receiver to combat the intersymbol interference (ISI problem over multipath fading channel. With the aid of MRC scheme, the proposed partial PIC technique can effectively perform the interference cancellation and acquire the benefit of time diversity gain. Finally, the proposed system can be extended to use for multiple antenna systems to provide excellent performance. Simulation results reveal that the proposed low complexity partial PIC-MRC SIMO system can provide robust performance and outperform the conventional PIC and the iterative frequency domain decision feedback equalizer (FD-DFE systems over multipath fading channel environment.

  18. Single Tree Vegetation Depth Estimation Tool for Satellite Services Link Design

    Directory of Open Access Journals (Sweden)

    Z. Hasirci

    2016-04-01

    Full Text Available Attenuation caused by tree shadowing is an important factor for describing the propagation channel of satellite services. Thus, vegetation effects should be determined by experimental studies or empirical formulations. In this study, tree types in the Black Sea Region of Turkey are classified based on their geometrical shapes into four groups such as conic, ellipsoid, spherical and hemispherical. The variations of the vegetation depth according to different tree shapes are calculated with ray tracing method. It is showed that different geometrical shapes have different vegetation depths even if they have same foliage volume for different elevation angles. The proposed method is validated with the related literature in terms of average single tree attenuation. On the other hand, due to decrease system requirements (speed, memory usage etc. of ray tracing method, an artificial neural network is proposed as an alternative. A graphical user interface is created for the above processes in MATLAB environment named vegetation depth estimation tool (VdET.

  19. Design and Fabrication of Single-Walled Carbon Nanonet Flexible Strain Sensors

    Directory of Open Access Journals (Sweden)

    Trung Kien Vu

    2012-03-01

    Full Text Available This study presents a novel flexible strain sensor for real-time strain sensing. The material for strain sensing is single-walled carbon nanonets, grown using the alcohol catalytic chemical vapor deposition method, that were encapsulated between two layers of Parylene-C, with a polyimide layer as the sensing surface. All of the micro-fabrication was compatible with the standard IC process. Experimental results indicated that the gauge factor of the proposed strain sensor was larger than 4.5, approximately 2.0 times greater than those of commercial gauges. The results also demonstrated that the gauge factor is small when the growth time of SWCNNs is lengthier, and the gauge factor is large when the line width of the serpentine pattern of SWCNNs is small.

  20. Design of indoor temperature and humidity detection system based on single chip microcomputer

    Science.gov (United States)

    Fu, Xiuwei; Fu, Li; Ma, Tianhui

    2018-03-01

    The indoor temperature and humidity detection system based on STC15F2K60S2 is designed in this paper. The temperature and humidity sensor DHT22 to monitor the indoor temperature and humidity are used, and the temperature and humidity data to the user's handheld device are wirelessly transmitted, when the temperature reaches or exceeds the user set the temperature alarm value, and the system sound and light alarm, to remind the user.

  1. Optimization of Amylase and Protease Production from Aspergillus awamori in Single Bioreactor Through EVOP Factorial Design Technique

    Directory of Open Access Journals (Sweden)

    Sangeeta Negi

    2006-01-01

    Full Text Available Evolutionary operation (EVOP factorial design technique was explored in order to economically produce amylase and protease at their optimum level in a single bioreactor by modified solid-state fermentation. Maximum yields of amylase and protease were achieved, using wheat bran as a substrate by a highly potent, locally isolated strain of Aspergillus awamori: Nakazawa MTCC 6652. The strain had been induced previously, inferring the ability to produce both enzymes concomitantly in a single bioreactor with their maximum capacity. The highest secretion of amylase and protease were measured to be 9420.6 and 1930 U/g, respectively, at 37 °C. pH and relative humidity were found to be optimum at 4 and 85 %, evaluated through EVOP method.

  2. Analysis, Design, and Experimental Verification of A Synchronous Reference Frame Voltage Control for Single-Phase Inverters

    DEFF Research Database (Denmark)

    Monfared, Mohammad; Golestan, Saeed; Guerrero, Josep M.

    2014-01-01

    Control of three-phase power converters in the synchronous reference frame is now a mature and well developed research topic. However, for single-phase converters, it is not as well-established as three-phase applications. This paper deals with the design of a synchronous reference frame multi-lo...... on a frequency response approach is presented. Finally, the theoretical achievements are supported by experimental results.......-loop control strategy for single phase inverter-based islanded distributed generation (DG) systems. The proposed controller uses a synchronous reference frame PI (SRFPI) controller to regulate the instantaneous output voltage, a capacitor current shaping loop in the stationary reference frame to provide active...

  3. A Novel Design of Rescue Capsule considering the Pressure Characteristics and Thermal Dynamic Response with Thermomechanical Coupling Action Subjected to Gas Explosion Load

    Directory of Open Access Journals (Sweden)

    Xiaowei Zhai

    2017-01-01

    Full Text Available To ensure the structural safety and reliability of coal mine rescue capsule in disastrous surroundings after gas explosion, in this paper, the thermomechanical coupling effect on a certain structure subjected to gas explosion was analyzed, and then a novel rescue capsule with a combination of radius and square features was designed according to the underground surroundings and relevant regulations on mine rescue devices. Foremost, the coupling mechanism of thermal-fluid-solid interaction between gas explosion shock wave and rescue capsule and the thermal dynamic response of the capsule subjected to explosion load of gas/air mixture was investigated and revealed by employing LS-DYNA. The variation laws and characteristics of stress field, displacement field, and temperature field of the capsule were analyzed based on the simulation results. Results show that the structural safety, tightness, and reliability of the capsule meet the requirements of the national safety regulations. The design method presented in this work provides a new thought for design of coal mine rescue capsule.

  4. Using single-case experimental design methodology to evaluate the effects of the ABC method for nursing staff on verbal aggressive behaviour after acquired brain injury.

    Science.gov (United States)

    Winkens, Ieke; Ponds, Rudolf; Pouwels, Climmy; Eilander, Henk; van Heugten, Caroline

    2014-01-01

    The ABC method is a basic and simplified form of behavioural modification therapy for use by nurses. ABC refers to the identification of Antecedent events, target Behaviours, and Consequent events. A single-case experimental AB design was used to evaluate the effects of the ABC method on a woman diagnosed with olivo-ponto-cerebellar ataxia. Target behaviour was verbal aggressive behaviour during ADL care, assessed at 9 time points immediately before implementation of the ABC method and at 36 time points after implementation. A randomisation test showed a significant treatment effect between the baseline and intervention phases (t = .58, p = .03; ES [Nonoverlap All Pairs] = .62). Visual analysis, however, showed that the target behaviour was still present after implementation of the method and that on some days the nurses even judged the behaviour to be more severe than at baseline. Although the target behaviour was still present after treatment, the ABC method seems to be a promising tool for decreasing problem behaviour in patients with acquired brain injury. It is worth investigating the effects of this method in future studies. When interpreting single-subject data, both visual inspection and statistical analysis are needed to determine whether treatment is effective and whether the effects lead to clinically desirable results.

  5. Design and synthesis of single-source molecular precursors to homogeneous multi-component oxide materials

    Science.gov (United States)

    Fujdala, Kyle Lee

    This dissertation describes the syntheses of single-source molecular precursors to multi-component oxide materials. These molecules possess a core metal or element with various combinations of -OSi(O tBu)3, -O2P(OtBu) 2, and -OB[OSi(OtBu)3] 2 ligands. Such molecules decompose under mild thermolytic conditions (models for oxide-supported metal species and multi-component oxides. Significantly, the first complexes to contain three or more heteroelements suitable for use in the TMP method have been synthesized. Compounds for use as single-source molecular precursors have been synthesized containing Al, B, Cr, Hf, Mo, V, W, and Zr, and their thermal transformations have been examined. Heterogeneous catalytic reactions have been examined for selected materials. Also, cothermolyses of molecular precursors and additional molecules (i.e., metal alkoxides) have been utilized to provide materials with several components for potential use as catalysts or catalyst supports. Reactions of one and two equivs of HOSi(OtBu) 3 with Cr(OtBu)4 afforded the first Cr(IV) alkoxysiloxy complexes (tBuO) 3CrOSi(OtBu)3 and ( tBuO)2Cr[OSi(OtBu) 3]2, respectively. The high-yielding, convenient synthesis of (tBuO)3CrOSi(O tBu)3 make this complex a useful single-source molecular precursor, via the TMP method, to Cr/Si/O materials. The thermal transformations of (tBuO)3CrOSi(O tBu)3 and (tBuO) 2Cr[OSi(OtBu)3]2 to chromia-silica materials occurr at low temperatures (≤180°C), to give isobutene as the major carbon-containing product. The material generated from the solid-state conversion of (tBuO) 3CrOSi(OtBu)3 (CrOS ss) has an unexpectedly high surface area of 315 m2 g-1 that is slightly reduced to 275 m2 g-1 after calcination at 500°C in O2. The xerogel obtained by the thermolysis of an n-octane solution of (tBuO)3CrOSi(O tBu)3 (CrOSixg) has a surface area of 315 m2 g-1 that is reduced to 205 m2 g-1 upon calcination at 500°C. Powder X-ray diffraction (PXRD) analysis revealed that Cr2O 3 is

  6. X-Ray Emission Spectrometer Design with Single-Shot Pump-Probe and Resonant Excitation Capabilities

    Energy Technology Data Exchange (ETDEWEB)

    Spoth, Katherine; /SUNY, Buffalo /SLAC

    2012-08-28

    Core-level spectroscopy in the soft X-ray regime is a powerful tool for the study of chemical bonding processes. The ultrafast, ultrabright X-ray pulses generated by the Linac Coherent Light Source (LCLS) allow these reactions to be studied in greater detail than ever before. In this study, we investigated a conceptual design of a spectrometer for the LCLS with imaging in the non-dispersive direction. This would allow single-shot collection of X-ray emission spectroscopy (XES) measurements with varying laser pump X-ray probe delay or a variation of incoming X-ray energy over the illuminated area of the sample. Ray-tracing simulations were used to demonstrate how the components of the spectrometer affect its performance, allowing a determination of the optimal final design. These simulations showed that the spectrometer's non-dispersive focusing is extremely sensitive to the size of the sample footprint; the spectrometer is not able to image a footprint width larger than one millimeter with the required resolution. This is compatible with a single shot scheme that maps out the laser pump X-ray probe delay in the non-dispersive direction as well as resonant XES applications at normal incidence. However, the current capabilities of the Soft X-Ray (SXR) beamline at the LCLS do not produce the required energy range in a small enough sample footprint, hindering the single shot resonant XES application at SXR for chemical dynamics studies at surfaces. If an upgraded or future beamline at LCLS is developed with lower monochromator energy dispersion the width can be made small enough at the required energy range to be imaged by this spectrometer design.

  7. Comparison of Inversion (“flipping”) Rates Among Different Port Designs: A Single-Center Experience

    International Nuclear Information System (INIS)

    Etezadi, Vahid; Trerotola, Scott O.

    2017-01-01

    PurposeTo compare incidence of port inversion among different types of implantable venous access devices.Materials and Methods Records of patients who underwent imaging-guided subcutaneous port placement without port fixation between July 2001 and April 2015 were reviewed with use of a quality assurance database. 1930 patients with complete follow-up (death or explant) were included in the study. Collected data included date and indication for port placement, port type, venous access site, immediate and long-term complications, indication for removal, and total number of catheter days. BMI of patients with inverted ports was also calculated.Results Port inversion within the pocket was observed in 18 patients (0.9%) including 7/82 (9%) of Dignity ports, 4/126 (3%) of Vaxcel plastic arm ports, 3/142 (2%) of Smartports, 2/100 (2%) of Powerports, 1/14 (7%) of Vaccess ports, and 1/1421 (0.07%) of Vortex LP ports. Among these designs, the inversion rate was significantly lower in Vortex LP ports (0.1%) (P < 0.05). There was a trend toward higher inversion rate of Dignity ports, which have a rectangular design with a relatively narrow base. Mean dwell in inverted ports was 114 days (7–580).Conclusion The incidence of port inversion without suture fixation of the port base to the pocket is extremely low. The present study shows differences in inversion incidence based on port design.Level of Evidence: Case Series, Level IV.

  8. Comparison of Inversion (“flipping”) Rates Among Different Port Designs: A Single-Center Experience

    Energy Technology Data Exchange (ETDEWEB)

    Etezadi, Vahid, E-mail: vahid.etezadi@umm.edu; Trerotola, Scott O., E-mail: streroto@uphs.upenn.edu [University of Pennsylvania Medical Center, Division of Interventional Radiology, Department of Radiology (United States)

    2017-04-15

    PurposeTo compare incidence of port inversion among different types of implantable venous access devices.Materials and Methods Records of patients who underwent imaging-guided subcutaneous port placement without port fixation between July 2001 and April 2015 were reviewed with use of a quality assurance database. 1930 patients with complete follow-up (death or explant) were included in the study. Collected data included date and indication for port placement, port type, venous access site, immediate and long-term complications, indication for removal, and total number of catheter days. BMI of patients with inverted ports was also calculated.Results Port inversion within the pocket was observed in 18 patients (0.9%) including 7/82 (9%) of Dignity ports, 4/126 (3%) of Vaxcel plastic arm ports, 3/142 (2%) of Smartports, 2/100 (2%) of Powerports, 1/14 (7%) of Vaccess ports, and 1/1421 (0.07%) of Vortex LP ports. Among these designs, the inversion rate was significantly lower in Vortex LP ports (0.1%) (P < 0.05). There was a trend toward higher inversion rate of Dignity ports, which have a rectangular design with a relatively narrow base. Mean dwell in inverted ports was 114 days (7–580).Conclusion The incidence of port inversion without suture fixation of the port base to the pocket is extremely low. The present study shows differences in inversion incidence based on port design.Level of Evidence: Case Series, Level IV.

  9. Design optimization of single mixed refrigerant natural gas liquefaction process using the particle swarm paradigm with nonlinear constraints

    International Nuclear Information System (INIS)

    Khan, Mohd Shariq; Lee, Moonyong

    2013-01-01

    The particle swarm paradigm is employed to optimize single mixed refrigerant natural gas liquefaction process. Liquefaction design involves multivariable problem solving and non-optimal execution of these variables can waste energy and contribute to process irreversibilities. Design optimization requires these variables to be optimized simultaneously; minimizing the compression energy requirement is selected as the optimization objective. Liquefaction is modeled using Honeywell UniSim Design ™ and the resulting rigorous model is connected with the particle swarm paradigm coded in MATLAB. Design constraints are folded into the objective function using the penalty function method. Optimization successfully improved efficiency by reducing the compression energy requirement by ca. 10% compared with the base case. -- Highlights: ► The particle swarm paradigm (PSP) is employed for design optimization of SMR NG liquefaction process. ► Rigorous SMR process model based on UniSim is connected with PSP coded in MATLAB. ► Stochastic features of PSP give more confidence in the optimality of complex nonlinear problems. ► Optimization with PSP notably improves energy efficiency of the SMR process.

  10. [The system design of an intraperitoneal perfusion machine for hyperthermic chemotherapy based on single chip microcomputer].

    Science.gov (United States)

    Zhang, Zhiyong; Yang, Xuandong; Li, Kaiyang

    2005-06-01

    A new kind of method for intraperitoneal hyperthermic chemotherapy has been proved to be very effective for the therapy of gastrointestinal cancer. In this article is reported an intraperitoneal perfusion machine which is designed for instituting the treatment. The liquor of the chemotherapy drug is infused into the abdomen after being heated by heating system; the liquor flows out of the abdomen is abandoned. The temperature of heating and the velocity of flow are controlled by MCU, thus the temperature of the liquor of the chemotherapy drug in the abdomen can be adjusted to the most favarable temperature.

  11. Single voxel magnetic resonance spectroscopy at 3 Tesla in a memory disorders clinic: early right hippocampal NAA/Cr loss in mildly impaired subjects.

    Science.gov (United States)

    Caserta, Maria T; Ragin, Ann; Hermida, Adriana P; Ahrens, R John; Wise, Leon

    2008-11-30

    In this study, we use magnetic resonance spectroscopy (MRS) at 3 Tesla to measure N-acetyl aspartate (NAA), myo-inositol (mI) and choline (Cho) to creatine (Cr) ratios in R (right) and L (left) hippocampi (H) in 8 mildly memory impaired (MMI), 6 probable Alzheimer's Disease (PRAD), and 17 control subjects. NAA/Cr was significantly reduced in the RH in the MMI group and bilaterally in the PRAD group vs. controls. No other metabolite differences were noted between the three groups. Five MMI subjects have converted to PRAD in follow-up. These findings suggest that RH NAA/Cr ratios measured at 3 Tesla may be a sensitive marker of future progression to dementia in a clinically defined population with isolated memory complaints.

  12. Effectiveness of ACT-Based Parenting Training to Mothers on the Depression of Children with Cleft Lip and Palate: A Single Subject Study

    OpenAIRE

    محمد صالح فقیهی; محمد باقر کجباف

    2017-01-01

    The purpose of this study was to determine the effectiveness of Parenting Training based on Acceptance and Commitment Therapy (ACT) to mothers on the depression of children with cleft lip and palate. The research method was based on a single case and individual intervention study. The sample was constituted of 65 Isfahanian children with cleft lip and palate. Parenting skills based on ACT were taught to five mothers of children with cleft lip and palate who achieved the minimum score in scree...

  13. The effect of phonation into a straw on the vocal tract adjustments and formant frequencies. A preliminary MRI study on a single subject completed with acoustic results

    Czech Academy of Sciences Publication Activity Database

    Laukkanen, A. M.; Horáček, Jaromír; Krupa, P.; Švec, J. G.

    2012-01-01

    Roč. 7, č. 1 (2012), s. 50-57 ISSN 1746-8094 R&D Projects: GA ČR GA101/08/1155 Institutional research plan: CEZ:AV0Z20760514 Keywords : vocal exercises * semi-occlusions * vocal tract setting Subject RIV: BI - Acoustics Impact factor: 1.074, year: 2012 http://www.sciencedirect.com/science/article/pii/S1746809411000097

  14. Single-Step Fabrication of Computationally Designed Microneedles by Continuous Liquid Interface Production.

    Directory of Open Access Journals (Sweden)

    Ashley R Johnson

    Full Text Available Microneedles, arrays of micron-sized needles that painlessly puncture the skin, enable transdermal delivery of medications that are difficult to deliver using more traditional routes. Many important design parameters, such as microneedle size, shape, spacing, and composition, are known to influence efficacy, but are notoriously difficult to alter due to the complex nature of microfabrication techniques. Herein, we utilize a novel additive manufacturing ("3D printing" technique called Continuous Liquid Interface Production (CLIP to rapidly prototype sharp microneedles with tuneable geometries (size, shape, aspect ratio, spacing. This technology allows for mold-independent, one-step manufacturing of microneedle arrays of virtually any design in less than 10 minutes per patch. Square pyramidal CLIP microneedles composed of trimethylolpropane triacrylate, polyacrylic acid and photopolymerizable derivatives of polyethylene glycol and polycaprolactone were fabricated to demonstrate the range of materials that can be utilized within this platform for encapsulating and controlling the release of therapeutics. These CLIP microneedles effectively pierced murine skin ex vivo and released the fluorescent drug surrogate rhodamine.

  15. The design of rapid turbidity measurement system based on single photon detection techniques

    Science.gov (United States)

    Yang, Yixin; Wang, Huanqin; Cao, Yangyang; Gui, Huaqiao; Liu, Jianguo; Lu, Liang; Cao, Huibin; Yu, Tongzhu; You, Hui

    2015-10-01

    A new rapid turbidity measurement system has been developed to measure the turbidity of drinking water. To determinate the turbidity quantitatively, the total intensity of scattering light has been measured and quantified as number of photons by adopting the single photon detection techniques (SPDT) which has the advantage of high sensitivity. On the basis of SPDT, the measurement system has been built and series of experiments have been carried out. Combining then the 90° Mie scattering theory with the principle of SPDT, a turbidity measurement model has been proposed to explain the experimental results. The experimental results show that a turbidity, which is as low as 0.1 NTU (Nephelometric Turbidity Units), can be measured steadily within 100 ms. It also shows a good linearity and stability over the range of 0.1-400 NTU and the precision can be controlled within 5% full scale. In order to improve its precision and stability, some key parameters, including the sampling time and incident light intensity, have been discussed. It has been proved that, to guarantee an excellent system performance, a good compromise between the measurement speed and the low power consumption should be considered adequately depending on the practical applications.

  16. Hysteresis loop design by geometry of garnet film element with single domain wall

    International Nuclear Information System (INIS)

    Skidanov, V A; Vetoshko, P M; Stempkovskiy, A L

    2011-01-01

    Numerical modeling and experimental investigation of magnetostatic stable states of two-domain structure in Bi-substituted uniaxial garnet film elements was made. Single domain walls (DW) between two opposite normally magnetized parts in isolated rectangular strip and strip-like bridge are found to exhibit different behavior. DW inside strip (bridge) suffers increasing repulsion (attraction) from nearest edge when shifted from element center. DW position center position is stable in isolated strip but bridge is magnetized spontaneously to one of two saturated states in zero external field. Isolated strip magnetization process occurs reversibly while bridge magnetization reversal occurs by coercive manner. Strip susceptibility and bridge coercive field are entirely defined by magnetostatic barrier created by element boundary stray field in case of constant DW length during magnetization reversal. Variation of strip and bridge boundary shape along DW trajectory gives the opportunity to create additional controllable potential profile due to DW surface energy modulation by DW length. Garnet elements with high Faraday rotation and low light switching field were developed for fine magnetic sensing and optical data processing applications.

  17. Design and experiments of a linear piezoelectric motor driven by a single mode.

    Science.gov (United States)

    Liu, Zhen; Yao, Zhiyuan; Li, Xiang; Fu, Qianwei

    2016-11-01

    In this contribution, we propose a novel linear piezoelectric motor with a compact stator that is driven by a single mode. The linear piezoelectric motor can realize bidirectional motion by changing the vibration modes of the stator. Finite element analysis is performed to determine the required vibration mode of the stator and obtain the optimal stator structure and dimensions. Furthermore, the trajectories of the driving foot are analyzed with and without consideration of the mechanical contact with the slider. It is shown that the trajectory of the driving foot is an oblique line when disregarding the contact, and the trajectory becomes an oblique ellipse while taking into account the contact. Finally, a prototype of the motor is fabricated based on the results of finite element analysis. The optimization results show that the motor reaches its maximum thrust force of 4.0 kg, maximum thrust-weight ratio of 33.3, maximum unloaded velocity of 385 mm/s under the excitation of Mode-B, and maximum unloaded velocity of 315 mm/s under the excitation of Mode-L.

  18. Pharmaceutical 3D printing: Design and qualification of a single step print and fill capsule.

    Science.gov (United States)

    Smith, Derrick M; Kapoor, Yash; Klinzing, Gerard R; Procopio, Adam T

    2018-06-10

    Fused deposition modeling (FDM) 3D printing (3DP) has a potential to change how we envision manufacturing in the pharmaceutical industry. A more common utilization for FDM 3DP is to build upon existing hot melt extrusion (HME) technology where the drug is dispersed in the polymer matrix. However, reliable manufacturing of drug-containing filaments remains a challenge along with the limitation of active ingredients which can sustain the processing risks involved in the HME process. To circumvent this obstacle, a single step FDM 3DP process was developed to manufacture thin-walled drug-free capsules which can be filled with dry or liquid drug product formulations. Drug release from these systems is governed by the combined dissolution of the FDM capsule 'shell' and the dosage form encapsulated in these shells. To prepare the shells, the 3D printer files (extension '.gcode') were modified by creating discrete zones, so-called 'zoning process', with individual print parameters. Capsules printed without the zoning process resulted in macroscopic print defects and holes. X-ray computed tomography, finite element analysis and mechanical testing were used to guide the zoning process and printing parameters in order to manufacture consistent and robust capsule shell geometries. Additionally, dose consistencies of drug containing liquid formulations were investigated in this work. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Straightforward single-calibrant quantification of seized designer drugs by liquid chromatography-chemiluminescence nitrogen detection.

    Science.gov (United States)

    Rasanen, Ilpo; Kyber, Marianne; Szilvay, Ilmari; Rintatalo, Janne; Ojanperä, Ilkka

    2014-04-01

    Sixty-one different psychoactive substances were quantified by liquid chromatography-chemiluminescence nitrogen detection (LC-CLND) in 177 samples, using a single secondary standard (caffeine), in a trial concerning the quantitative purity assessment of drug-related material seized by the police in 2011-2012 and customs in 2011-2013 in Finland. The substances found were predominantly substituted phenethylamines, cathinones, tryptamines and synthetic cannabinoids, which were identified by appropriate methods prior to submitting the samples for quantification by LC-CLND. The equimolarity and expanded uncertainty of measurement by LC-CLND were on average 95% and 13%, respectively, based on 16 different substances. The median (mean) purity of stimulant/hallucinogenic drug samples seized at the border was 92.9% (87.6%) and in the street 82.0% (64.5%). The corresponding figures for powdery synthetic cannabinoid samples seized at the border and in the street were 99.0% (96.8%) and 90.0% (92.2%), respectively. There was generally only one active drug to be quantified in each sample. Seized herbal samples contained 0.15-9.2% of between one and three components. LC-CLND was found to be suitable for quantification of the nitrogen-containing drugs encountered in the study, showing sufficient N-equimolarity for both stimulant/hallucinogenic drugs and synthetic cannabinoids. The technique possesses great potential as a standard technique in forensic laboratories. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  20. Design, structural investigation and physicochemical properties of benzotriazolium m-nitrophthalate monohydrate single crystals

    Science.gov (United States)

    Mekala, R.; Mani, Rajaboopathi; Jagdish, P.; Mathammal, R.

    2018-04-01

    The single crystals of organic salt benzotriazolium m-nitrophthalate monohydrate were grown by slow evaporation technique. It crystallizes in orthorhombic system with space group Pbca. The molecular interactions of the compound have been pictured using Hirshfeld surfaces and fingerprints plots and the results were compared with BZD+·mNPA-. The functional groups were identified by FTIR and FT-Raman spectra. The proton transfer from acid to base was identified from the 1H and 13C NMR spectra. The absorption and emission spectrum of BTA+·mNPA-·H2O was recorded in aqueous solution and different solvents, respectively The HOMO and LUMO energy gap of benzotriazole and BTA+·mNPA-·H2O were calculated using density functional theory (DFT). The thermal stability and melting point of hydrated salt was analysed and compared by TG-DTG/DSC study. The anti-oxidant activity of the title compound was evaluated by DPPH and ABTS+ Radical scavenging assay. The anti-microbial and anti-cancer activity showed a potential impact in the crystal.

  1. Immediate effect of nonspecific mandibular mobilization on postural control in subjects with temporomandibular disorder: a single-blind, randomized, controlled clinical trial.

    Science.gov (United States)

    Amaral, Ana P; Politti, Fabiano; Hage, Yasmin E; Arruda, Eric E C; Amorin, Cesar F; Biasotto-Gonzalez, Daniela A

    2013-01-01

    Temporomandibular disorder (TMD) is considered multifactorial and is defined as a group of pain conditions characterized by functional stomatognathic system alterations, which may be affected by or related disrupted postural control. Assess the immediate effect of nonspecific mandibular mobilization (NMM) on the postural control of subjects diagnosed or not with TMD. A simple-blind, randomized, controlled clinical trial was performed involving 50 subjects of both genders assigned to two groups: the TMD group and the control group. TMD was diagnosed according to the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD). A stabilometric assessment was performed by testing subjects in a quiet stance on a dual force platform under two visual conditions (eyes open and eyes closed). The Center of Pressure (CoP)-related variables analyzed were displacement, amplitude, speed of anterior-posterior (AP) and medial-lateral (ML) displacements and CoP sway area. The mean values of each variable were compared, considering the accepted significance value of ppostural control in patients with TMD.

  2. Design and Construction of an Autonomous Low-Cost Pulse Height Analyzer and a Single Channel Analyzer for Moessbauer Spectroscopy

    International Nuclear Information System (INIS)

    Velasquez, A.A.; Trujillo, J.M.; Morales, A.L.; Tobon, J.E.; Gancedo, J.R.; Reyes, L.

    2005-01-01

    A multichannel analyzer (MCA) and a single channel-analyzer (SCA) for Moessbauer spectrometry application have been designed and built. Both systems include low-cost digital and analog components. A microcontroller manages, either in PHA or MCS mode, the data acquisition, data storage and setting of the pulse discriminator limits. The user can monitor the system from an external PC through the serial port with the RS232 communication protocol. A graphic interface made with the LabVIEW software allows the user to adjust digitally the lower and upper limits of the pulse discriminator, and to visualize as well as save the PHA spectra in a file. The system has been tested using a 57Co radioactive source and several iron compounds, yielding satisfactory results. The low cost of its design, construction and maintenance make this equipment an attractive choice when assembling a Moessbauer spectrometer

  3. Design and implementation of an efficient single layer five input majority voter gate in quantum-dot cellular automata.

    Science.gov (United States)

    Bahar, Ali Newaz; Waheed, Sajjad

    2016-01-01

    The fundamental logical element of a quantum-dot cellular automata (QCA) circuit is majority voter gate (MV). The efficiency of a QCA circuit is depends on the efficiency of the MV. This paper presents an efficient single layer five-input majority voter gate (MV5). The structure of proposed MV5 is very simple and easy to implement in any logical circuit. This proposed MV5 reduce number of cells and use conventional QCA cells. However, using MV5 a multilayer 1-bit full-adder (FA) is designed. The functional accuracy of the proposed MV5 and FA are confirmed by QCADesigner a well-known QCA layout design and verification tools. Furthermore, the power dissipation of proposed circuits are estimated, which shows that those circuits dissipate extremely small amount of energy and suitable for reversible computing. The simulation outcomes demonstrate the superiority of the proposed circuit.

  4. An Optimized Design of Single-Channel Beta-Gamma Coincidence Phoswich Detector by Geant4 Monte Carlo Simulations

    Directory of Open Access Journals (Sweden)

    Weihua Zhang

    2011-01-01

    Full Text Available An optimized single-channel phoswich well detector design has been proposed and assessed in order to improve beta-gamma coincidence measurement sensitivity of xenon radioisotopes. This newly designed phoswich well detector consists of a plastic beta counting cell (BC404 embedded in a CsI(Tl crystal coupled to a photomultiplier tube. The BC404 is configured in a cylindrical pipe shape to minimise light collection deterioration. The CsI(Tl crystal consists of a rectangular part and a semicylindrical scintillation part as a light reflector to increase light gathering. Compared with a PhosWatch detector, the final optimized detector geometry showed 15% improvement in the energy resolution of a 131mXe 129.4 keV conversion electron peak. The predicted beta-gamma coincidence efficiencies of xenon radioisotopes have also been improved accordingly.

  5. Structural Design of Systems with Safe Behavior under Single and Multiple Faults

    DEFF Research Database (Denmark)

    Blanke, Mogens; Staroswiecki, Marcel

    2006-01-01

    Handling of multiple simultaneous faults is a complex issue in fault-tolerant control. The design task is particularly made difficult by to the numerous different cases that need be analyzed. Aiming at safe fault-handling, this paper shows how structural analysis can be applied to find...... to structural analysis to disclose which faults could be isolated from a structural point of view using active fault isolation. Results from application on a marine control system illustrate the concepts....... the analytical redundancy relations for all relevant combinations of faults, and can cope with the complexity and size of a real system. Being essential for fault-tolerant control schemes that shall handle particular cases of faults/failures, fault isolation is addressed. The paper introduces an extension...

  6. A practical guide to the design and construction of a single wire beverage antenna

    Science.gov (United States)

    Spong, H. L.

    1980-09-01

    Theoretical results are presented which show the performance likely to result from using differing antenna heights, lengths and wire sizes and from operating with different ground conductivities. These studies were undertaken to provide practical advice for constructors and operators. Design parameters can be easily obtained with the aid of computer programs and an antenna can be rapidly constructed from readily available materials. Directivity can be increased by adding more elements, either in parallel or on a radial basis. A particular performance can be achieved with great latitude in the parameters. Good low angle performance can be achieved without large ground screens. A directional array can be made by switching between a number of elements set up on different bearings.

  7. Designing Kerr interactions using multiple superconducting qubit types in a single circuit

    Science.gov (United States)

    Elliott, Matthew; Joo, Jaewoo; Ginossar, Eran

    2018-02-01

    The engineering of Kerr interactions is of great interest for processing quantum information in multipartite quantum systems and for investigating many-body physics in a complex cavity-qubit network. We study how coupling multiple different types of superconducting qubits to the same cavity modes can be used to modify the self- and cross-Kerr effects acting on the cavities and demonstrate that this type of architecture could be of significant benefit for quantum technologies. Using both analytical perturbation theory results and numerical simulations, we first show that coupling two superconducting qubits with opposite anharmonicities to a single cavity enables the effective self-Kerr interaction to be diminished, while retaining the number splitting effect that enables control and measurement of the cavity field. We demonstrate that this reduction of the self-Kerr effect can maintain the fidelity of coherent states and generalised Schrödinger cat states for much longer than typical coherence times in realistic devices. Next, we find that the cross-Kerr interaction between two cavities can be modified by coupling them both to the same pair of qubit devices. When one of the qubits is tunable in frequency, the strength of entangling interactions between the cavities can be varied on demand, forming the basis for logic operations on the two modes. Finally, we discuss the feasibility of producing an array of cavities and qubits where intermediary and on-site qubits can tune the strength of self- and cross-Kerr interactions across the whole system. This architecture could provide a way to engineer interesting many-body Hamiltonians and be a useful platform for quantum simulation in circuit quantum electrodynamics.

  8. Design of a single-borehole hydraulic test programme allowing for interpretation-based errors

    International Nuclear Information System (INIS)

    Black, J.H.

    1987-07-01

    Hydraulic testing using packers in single boreholes is one of the most important sources of data to safety assessment modelling in connection with the disposal of radioactive waste. It is also one of the most time-consuming and expensive. It is important that the results are as reliable as possible and as accurate as necessary for the use that is made of them. There are many causes of possible error and inaccuracy ranging from poor field practice to inappropriate interpretation procedure. The report examines and attempts to quantify the size of error arising from the accidental use of an inappropriate or inadequate interpretation procedure. In doing so, it can be seen which interpretation procedure or combination of procedures results in least error. Lastly, the report attempts to use the previous conclusions from interpretation to propose forms of field test procedure where interpretation-based errors will be minimised. Hydraulic tests (sometimes known as packer tests) come in three basic forms: slug/pulse, constant flow and constant head. They have different characteristics, some measuring a variable volume of rock (dependent on hydraulic conductivity) and some having a variable duration (dependent on hydraulic conductivity). A combination of different tests in the same interval is seen as desirable. For the purposes of assessing interpretation-based errors, slug and pulse tests are considered together as are constant flow and constant head tests. The same method is used in each case to assess errors. The method assumes that the simplest analysis procedure (cylindrical flow in homogeneous isotropic porous rock) will be used on each set of field data. The error is assessed by calculating synthetic data for alternative configurations (e.g. fissured rock, anisotropic rock, inhomogeneous rock - i.e. skin - etc.) and then analyzing this data using the simplest analysis procedure. 28 refs., 26 figs

  9. Design of 650 MHz, β=0.61, 5-cell SRF cavity and development of single cell niobium cavity

    International Nuclear Information System (INIS)

    Seth, Sudeshna; Som, Sumit; Bhattacharyya, Pranab

    2015-01-01

    In India, DAE laboratories and other institutes are now actively involved in research and development activities on SRF cavities and associated technologies for the proposed high current, high energy proton linear accelerators like ISNS/IADS and also for the FERMILAB PIP-II program under Indian institutions-Fermilab collaboration (IIFC). As part of the above activities, VECC, Kolkata, has been involved in the design, analysis and development of a 650 MHz, β=0.61, 5-cell elliptical shape Superconducting RF linac cavity. RF design involves optimization of the geometry to get acceptable values of field enhancement factors (magnetic and electric), R/Q , Geometric factor, coupling factor and field flatness. This paper describes the RF design using 2-D superfish and 3-D CST Microwave studio and multipacting analysis using 2-D Multipac2.1 and 3-D CST Particle Studio. A prototype 1-cell aluminum cavity and a prototype 5-cell copper cavity have been fabricated using die-punch assembly designed for fabrication of elliptical half-cells to check the procedures for forming and to make sure the desired frequency and field flatness could be obtained. RF characterization has been carried out for both the prototypes using Vector Network Analyzer and Bead pull measurement set up.The fabrication of a single-cell niobium cavity has been carried out indigenously and with the help of Electron Beam Welding (EBW) facility at IUAC, New Delhi. CMM measurement and RF characterization of the niobium half cells and full cell cavities have been carried out. This paper describes the development and measurement of prototype cavities and single cell niobium cavity. (author)

  10. Expanding subjectivities

    DEFF Research Database (Denmark)

    Lundgaard Andersen, Linda; Soldz, Stephen

    2012-01-01

    A major theme in recent psychoanalytic thinking concerns the use of therapist subjectivity, especially “countertransference,” in understanding patients. This thinking converges with and expands developments in qualitative research regarding the use of researcher subjectivity as a tool......-Saxon and continental traditions, this special issue provides examples of the use of researcher subjectivity, informed by psychoanalytic thinking, in expanding research understanding....

  11. Design and characterization of a single channel two-liquid capacitor and its application to hyperelastic strain sensing.

    Science.gov (United States)

    Liu, Shanliangzi; Sun, Xiaoda; Hildreth, Owen J; Rykaczewski, Konrad

    2015-03-07

    Room temperature liquid-metal microfluidic devices are attractive systems for hyperelastic strain sensing. These liquid-phase electronics are intrinsically soft and retain their functionality even when stretched to several times their original length. Currently two types of liquid metal-based strain sensors exist for in-plane measurements: single-microchannel resistive and two-microchannel capacitive devices. With a winding serpentine channel geometry, these sensors typically have a footprint of about a square centimeter. This large footprint of an individual device limits the number of sensors that can be embedded into, for example, electronic fabric or skin. In this work we introduce an alternative capacitor design consisting of two liquid metal electrodes separated by a liquid dielectric material within a single straight channel. Using a liquid insulator instead of a solid elastomer enables us to tailor the system's capacitance by selecting high or low dielectric constant liquids. We quantify the effects of the electrode geometry including the diameter, spacing, and meniscus shape as well as the dielectric constant of the insulating liquid on the overall system's capacitance. We also develop a procedure for fabricating the two-liquid capacitor within a single straight polydiemethylsiloxane channel and demonstrate that this device can have about 25 times higher capacitance per sensor's base area when compared to two-channel liquid metal capacitors. Lastly, we characterize the response of this compact device to strain and identify operational issues arising from complex hydrodynamics near liquid-liquid and liquid-elastomer interfaces.

  12. Design and testing of an integrated electronically controlled capacitor for integral and fractional horse power single phase induction motor

    International Nuclear Information System (INIS)

    Faiz, Jawad; Kasebi, F.; Pillay, P.

    2004-01-01

    This paper addresses a problem that occurs in many small appliances. As such, it is an important problem of energy utilization. To improve the performance of a single phase capacitor start/run induction motor, FET type power transistors could be used to replace a SCR H bridge. Such a configuration can lead to a simpler and more inexpensive circuit for the electronically controlled capacitor. In this paper, ICs and an OP-AMP are used to design an electronically controlled capacitor for a single phase induction motor. The design can compensate for the input voltage fluctuations that are present in the normal operation of the motor. In addition, an improvement in its performance can be obtained. At present, the use of a tachometer can be considered a disadvantage of the proposed scheme. Thus, a configuration that enables removal of the tachometer, while maintaining reasonable cost, is desirable. In addition, replacing the ac capacitor with one rated for dc can lead to a system reduction, in addition to a considerable reduction in the size of the circuit due to the use of integrated circuits

  13. TA Treatment of Depression - A Hermeneutic Single-Case Efficacy Design Study - ‘Linda’ - a mixed outcome case

    Directory of Open Access Journals (Sweden)

    Mark Widdowson

    2013-07-01

    Full Text Available Hermeneutic Single-Case EfficacyDesign (HSCED is a systematic case study research method involving the cross-examination of mixed method data to generate both plausible arguments that the client changed due to therapy and alternative explanations. The present study is the fourth article of a case series which has investigated the process and outcome of transactional analysis psychotherapy using Hermeneutic Single-Case Efficacy Design (Elliott 2002. The client, Linda, was a 45 yearold white British woman with mild depression who attended nine sessions of therapy. The conclusion of the judges was that this was a mixed-outcome case:whilst the client improved over the course of therapy and was positive about her experience of therapy, her changes did not last when she experienced considerable stressful events during follow-up. Linda provided a detailed and idiosyncratic description of the aspects of the therapy which were most helpful for her. A cross-case comparison with other cases in this series suggests several interesting features which are worthy of further investigation. Specifically, the use of a shared theoretical framework and an egalitarian therapeutic relationship were helpful. As with other cases in this series, the client experienced positive changes in her interpersonal relationships suggesting that this outcome of TA therapy warrants further investigation

  14. Design comparison of single phase outer and inner-rotor hybrid excitation flux switching motor for hybrid electric vehicles

    Science.gov (United States)

    Mazlan, Mohamed Mubin Aizat; Sulaiman, Erwan; Husin, Zhafir Aizat; Othman, Syed Muhammad Naufal Syed; Khan, Faisal

    2015-05-01

    In hybrid excitation machines (HEMs), there are two main flux sources which are permanent magnet (PM) and field excitation coil (FEC). These HEMs have better features when compared with the interior permanent magnet synchronous machines (IPMSM) used in conventional hybrid electric vehicles (HEVs). Since all flux sources including PM, FEC and armature coils are located on the stator core, the rotor becomes a single piece structure similar with switch reluctance machine (SRM). The combined flux generated by PM and FEC established more excitation fluxes that are required to produce much higher torque of the motor. In addition, variable DC FEC can control the flux capabilities of the motor, thus the machine can be applied for high-speed motor drive system. In this paper, the comparisons of single-phase 8S-4P outer and inner rotor hybrid excitation flux switching machine (HEFSM) are presented. Initially, design procedures of the HEFSM including parts drawing, materials and conditions setting, and properties setting are explained. Flux comparisons analysis is performed to investigate the flux capabilities at various current densities. Then the flux linkages of PM with DC FEC of various DC FEC current densities are examined. Finally torque performances are analyzed at various armature and FEC current densities for both designs. As a result, the outer-rotor HEFSM has higher flux linkage of PM with DC FEC and higher average torque of approximately 10% when compared with inner-rotor HEFSM.

  15. Design Of Single-Axis And Dual-Axis Solar Tracking Systems Protected Against High Wind Speeds

    Directory of Open Access Journals (Sweden)

    Mai Salaheldin Elsherbiny

    2017-09-01

    Full Text Available Solar energy is rapidly gaining ground as an important mean of expanding renewable energy use. Solar tracking is employed in order to maximize collected solar radiation by a photovoltaic panel. In this paper we present a prototype for Automatic solar tracker that is designed using Arduino UNO with Wind sensor to Cease Wind effect on panels if wind speed exceeds certain threshold. The Proposed solar tracker tracks the location of the sun anywhere in any time by calculating the position of the sun. For producing the maximum amount of solar energy a solar panel must always be perpendicular to the source of light. Because the sun motion plane varies daily and during the day it moves from east to west one needs two axis tracking to follow the suns position. Maximum possible power is collected when two axis tracking is done. However two axis tracking is relatively costly and complex. A compromise between maximum power collection and system simplicity is obtained by single axis tracking where the plane North south axis is fixed while the east west motion is accomplished. This work deals with the design of both single and two axis tracking systems. Automatic trackers is also compared to Fixed one in terms of Energy generated Efficiency Cost and System reliability.

  16. A single IGCC design for variable CO{sub 2} capture

    Energy Technology Data Exchange (ETDEWEB)

    O' Keefe, L.F.; Griffiths, J.; Wainwright, J.M. [Chevron Texaco Worldwide Power and Gasification, Houston, TX (United States)

    2002-07-01

    Global warming and the production of greenhouse gases (GHG) have become an important issue in many countries around the world. While there has been a heightened sense of awareness that the combustion of fossil fuels produces the majority of the controllable carbon dioxide released to the atmosphere, there have been few substantive solutions that produce economically realistic solutions. Moreover, some fossil fuels, like coal, are viewed negatively due to their relatively high carbon content per Btu. Integrated Gasification Combined Cycle (IGCC) offers the option of a realistic, economically viable solution for reducing, by pre-combustion capture, significant amounts of CO{sub 2} while using existing commercially proven technologies. The novel IGCC flowscheme is designed so that the power plant can be built and operated without CO{sub 2} removal and later upgraded to low CO{sub 2} emissions at minimal additional cost. The novel flowscheme is based on commercially proven technology using processes that are in operation today. Overall performance and capital cost estimates are presented and two other possible applications of the novel flowscheme are discussed in this paper. 17 refs., 3 figs., 2 tabs.

  17. A design approach for improving the performance of single-grid planar retarding potential analyzers

    International Nuclear Information System (INIS)

    Davidson, R. L.; Earle, G. D.

    2011-01-01

    Planar retarding potential analyzers (RPAs) have a long flight history and have been included on numerous spaceflight missions including Dynamics Explorer, the Defense Meteorological Satellite Program, and the Communications/Navigation Outage Forecast System. RPAs allow for simultaneous measurement of plasma composition, density, temperature, and the component of the velocity vector normal to the aperture plane. Internal conductive grids are used to approximate ideal potential planes within the instrument, but these grids introduce perturbations to the potential map inside the RPA and cause errors in the measurement of the parameters listed above. A numerical technique is presented herein for minimizing these grid errors for a specific mission by varying the depth and spacing of the grid wires. The example mission selected concentrates on plasma dynamics near the sunset terminator in the equatorial region. The international reference ionosphere model is used to discern the average conditions expected for this mission, and a numerical model of the grid-particle interaction is used to choose a grid design that will best fulfill the mission goals.

  18. Solar project description for Design Construction Association single family dwelling, Big Fork, Montana

    Science.gov (United States)

    1980-04-01

    A solar energy system was installed in a 2100 sq ft house located in Big Fork, Montana. The system is designed to provide solar energy for heating and domestic hot water. Solar energy is collected by flat plate collectors with a gross area of 792 square feet. The collector banks are mounted on the roof of the house and face due south at an angle of 45 deg to the horizontal optimizing solar energy collection. Solar energy is transferred from the collector array to a 1500 gallon storage tank. Water is used as the heat collection, transfer and storage medium. Freeze protection is provided by use of a drain down system. Space heating demands are met by circulating hot water from storage through baseboard units in the distribution system of the house. Auxiliary space heating is provided by an electrical heating element in the boiler. Similarly, an electrical heating element in the DHW tank provides energy for water heating. The dwelling was fully instrumented for performance evaluation since October 1977 and the data is integrated into the National Solar Data Network.

  19. Angle dependence on the anisotropic magnetoresistance amplitude of a single-contacted Ni nanowire subjected to a thermo-mechanical strain

    Energy Technology Data Exchange (ETDEWEB)

    Melilli, G.; Madon, B.; Wegrowe, J.-E., E-mail: jean-eric.wegrowe@polytechnique.edu; Clochard, M.-C., E-mail: clochard@cea.fr

    2015-12-15

    The effects of thermoelastic and piezoelectric strain of an active track-etched β-PVDF polymer matrix on an electrodeposited single-contacted Ni nanowire (NW) are investigated at the nanoscale by measuring the change of magnetization (i.e. using the inverse magnetostriction effect). The magnetization state is measured locally by anisotropic magnetoresistance (AMR). The ferromagnetic NW plays thus the role of a mechanical probe that allows the effects of mechanical strain to be characterized and described qualitatively and quantitatively. The inverse magnetostriction was found to be responsible for a quasi-disappearance of the AMR signal for a variation of the order of ΔT ≈ 10 K. In other terms, the variation of the magnetization due to the stress compensates the effect of external magnetic field applied on the NW resistance. The induced stress field in a single Ni NW was found 1000 time higher than the bulk stress field (due to thermal expansion measured on the PVDF). This amplification could be attributed to three nanoscopic effects: (1) a stress mismatch between the Ni NW and the membrane, (2) a non-negligible role of the surface tension on Ni NW Young modulus, and (3) the possibility of non-linear stress–strain law. We investigate here the role of these different contributions using track-etched polymer membranes irradiated at various angles (α{sub irrad}) leading to, after electrodeposition, embedded Ni NWs of different orientations.

  20. Angle dependence on the anisotropic magnetoresistance amplitude of a single-contacted Ni nanowire subjected to a thermo-mechanical strain

    Science.gov (United States)

    Melilli, G.; Madon, B.; Wegrowe, J.-E.; Clochard, M.-C.

    2015-12-01

    The effects of thermoelastic and piezoelectric strain of an active track-etched β-PVDF polymer matrix on an electrodeposited single-contacted Ni nanowire (NW) are investigated at the nanoscale by measuring the change of magnetization (i.e. using the inverse magnetostriction effect). The magnetization state is measured locally by anisotropic magnetoresistance (AMR). The ferromagnetic NW plays thus the role of a mechanical probe that allows the effects of mechanical strain to be characterized and described qualitatively and quantitatively. The inverse magnetostriction was found to be responsible for a quasi-disappearance of the AMR signal for a variation of the order of ΔT ≈ 10 K. In other terms, the variation of the magnetization due to the stress compensates the effect of external magnetic field applied on the NW resistance. The induced stress field in a single Ni NW was found 1000 time higher than the bulk stress field (due to thermal expansion measured on the PVDF). This amplification could be attributed to three nanoscopic effects: (1) a stress mismatch between the Ni NW and the membrane, (2) a non-negligible role of the surface tension on Ni NW Young modulus, and (3) the possibility of non-linear stress-strain law. We investigate here the role of these different contributions using track-etched polymer membranes irradiated at various angles (αirrad) leading to, after electrodeposition, embedded Ni NWs of different orientations.