WorldWideScience

Sample records for single stage accelerator

  1. Performance of the rebuilt SUERC single-stage accelerator mass spectrometer

    Science.gov (United States)

    Shanks, Richard P.; Ascough, Philippa L.; Dougans, Andrew; Gallacher, Paul; Gulliver, Pauline; Rood, Dylan H.; Xu, Sheng; Freeman, Stewart P. H. T.

    2015-10-01

    The SUERC bipolar single-stage accelerator mass spectrometer (SSAMS) has been dismantled and rebuilt to accommodate an additional rotatable pre-accelerator electrostatic spherical analyser (ESA) and a second ion source injector. This is for the attachment of an experimental positive-ion electron cyclotron resonance (ECR) ion source in addition to a Cs-sputter source. The ESA significantly suppresses oxygen interference to radiocarbon detection, and remaining measurement interference is now thought to be from 13C injected as 13CH molecule scattering off the plates of a second original pre-detector ESA.

  2. Single-stage accelerator mass spectrometer radiocarbon-interference identification and positive-ionisation characterisation

    Energy Technology Data Exchange (ETDEWEB)

    Wilcken, K.M., E-mail: klaus.wilcken@ansto.gov.au [Scottish Universities Environmental Research Centre, Scottish Enterprise Technology Park, East Kilbride G75 0QF (United Kingdom); Freeman, S.P.H.T.; Xu, S.; Dougans, A. [Scottish Universities Environmental Research Centre, Scottish Enterprise Technology Park, East Kilbride G75 0QF (United Kingdom)

    2013-01-15

    A single-stage accelerator mass spectrometer (SSAMS) is a good alternative to conventional spectrometers based on tandem electrostatic acceleration for radiocarbon measurement and permits experimentation with both negative and positive carbon ions. However, such {sup 14}C AMS of either polarity ions is limited by an interference. In the case of anion acceleration we have newly determined this to be summed {sup 13}C and {sup 16}O by improvising an additional Wien filter on our SSAMS deck. Also, {sup 14}C AMS might be improved by removing its dependency on negative-ionisation in a sputter ion source. This requires negative-ionisation of sample atoms elsewhere to suppress the {sup 14}N interference, which we accomplish by transmitting initially positive ions through a thin membrane. The ionisation dependence on ion-energy is found to be consistent with previous experimentation with vapours and thicker foils.

  3. Single-stage osseointegrated reconstruction and rehabilitation of lower limb amputees: the Osseointegration Group of Australia Accelerated Protocol-2 (OGAAP-2) for a prospective cohort study.

    Science.gov (United States)

    Al Muderis, Munjed; Lu, William; Tetsworth, Kevin; Bosley, Belinda; Li, Jiao Jiao

    2017-03-22

    Lower limb amputations have detrimental influences on the quality of life, function and body image of the affected patients. Following amputation, prolonged rehabilitation is required for patients to be fitted with traditional socket prostheses, and many patients experience symptomatic socket-residuum interface problems which lead to reduced prosthetic use and quality of life. Osseointegration has recently emerged as a novel approach for the reconstruction of amputated limbs, which overcomes many of the socket-related problems by directly attaching the prosthesis to the skeletal residuum. To date, the vast majority of osseointegration procedures worldwide have been performed in 2 stages, which require at least 4 months and up to 18 months for the completion of reconstruction and rehabilitation from the time of the initial surgery. The current prospective cohort study evaluates the safety and efficacy of a single-stage osseointegration procedure performed under the Osseointegration Group of Australia Accelerated Protocol-2 (OGAAP-2), which dramatically reduces the time of recovery to ∼3-6 weeks. The inclusion criteria for osseointegrated reconstruction under the OGAAP-2 procedure are age over 18 years, unilateral transfemoral amputation and experiencing problems or difficulties in using socket prostheses. All patients receive osseointegrated implants which are press-fitted into the residual bone. Functional and quality-of-life outcome measures are recorded preoperatively and at defined postoperative follow-up intervals up to 2 years. Postoperative adverse events are also recorded. The preoperative and postoperative values are compared for each outcome measure, and the benefits and harms of the single-stage OGAAP-2 procedure will be compared with the results obtained using a previously employed 2-stage procedure. This study has received ethics approval from the University of Notre Dame, Sydney, Australia (014153S). The study outcomes will be disseminated

  4. Acceleration of single pixel imaging

    Science.gov (United States)

    Nitta, K.

    2018-01-01

    A method for single pixel imaging (SPI) is introduced. The method is proposed to accelerate optical measurement. The method is also useful for high-definition imaging. The processing procedure of the method is described and some features of the based on the proposed method is described.

  5. [Second stage of labor: Does accelerations matter?].

    Science.gov (United States)

    Martí-Gamboa, S; Rodríguez-Lázaro, L; Redrado-Giménez, O; Ruiz-Sada, J; Castón-Mateo, S

    2016-05-01

    Accelerations role during the second stage of labor has not been studied and current classification system NICHD downplays its presence. The objective of this study is to determine validity for acidemia detection of the loss of accelerations during the second stage of labor. This is a one year retrospective case-control study of 102 neonates with acidemia defined as an umbilical cord gas pH≤7.10 compared to 100 non acidemic controls. The last thirty minutes of CTG were evaluated by two obstetricians blind to clinical and outcome data that classified tracings into categories according to NICHD definitions, determining the presence or absence of accelerations. Validity of NICHD categories and absence of accelerations were calculated. 85% of fetuses presented a category II tracing in the last 30 minutes of labor. Absence of accelerations was associated with neonatal acidemia (ORa 4.43). Category II tracings were not associated with acidemia after adjusting for confounding factors.Validity of the absence of accelerations during the second stage of labor was higher in terms of sensitivity (80.3%), specificity (54%) and global value (67%) to that of the presence of a category II tracing (96%, 24% and 60% respectively) in this period. The absence of accelerations during the second stage of labor shows a bigger validity for neonatal acidemia than the presence of a category II tracing.

  6. Two stage-type railgun accelerator

    International Nuclear Information System (INIS)

    Ogino, Mutsuo; Azuma, Kingo.

    1995-01-01

    The present invention provides a two stage-type railgun accelerator capable of spiking a flying body (ice pellet) formed by solidifying a gaseous hydrogen isotope as a fuel to a thermonuclear reactor at a higher speed into a central portion of plasmas. Namely, the two stage-type railgun accelerator accelerates the flying body spiked from a initial stage accelerator to a portion between rails by Lorentz force generated when electric current is supplied to the two rails by way of a plasma armature. In this case, two sets of solenoids are disposed for compressing the plasma armature in the longitudinal direction of the rails. The first and the second sets of solenoid coils are previously supplied with electric current. After passing of the flying body, the armature formed into plasmas by a gas laser disposed at the back of the flying body is compressed in the longitudinal direction of the rails by a magnetic force of the first and the second sets of solenoid coils to increase the plasma density. A current density is also increased simultaneously. Then, the first solenoid coil current is turned OFF to accelerate the flying body in two stages by the compressed plasma armature. (I.S.)

  7. Detailed experimental results for laser acceleration staging

    Directory of Open Access Journals (Sweden)

    W. D. Kimura

    2001-10-01

    Full Text Available Detailed experimental results of staging two laser-driven, relativistic electron accelerators are presented. During the experiment called STELLA (staged electron laser acceleration, an inverse free-electron laser (IFEL is used to modulate the electron energy, thereby, causing ∼3 fs microbunches to form separated by the laser wavelength at 10.6 μm (equivalent to a 35 fs period. A second IFEL accelerates the electrons depending upon the phase of the microbunches entering the second IFEL with respect to the laser beam driving the second IFEL. The data presented includes electron energy spectra as a function of the phase delay and laser power driving the first IFEL. Also shown is a comparison with the computer model, which includes space charge and misalignment effects.

  8. Augment-type two stage accelerator

    International Nuclear Information System (INIS)

    Ogino, Mutsuo; Azuma, Kingo.

    1995-01-01

    When a flying body accelerated by a gas gun at a first stage enters into an augment rail passing through an introduction tube, an ignition capacitor for initial plasmas is turned ON to apply a voltage between the augment rails. Subsequently, the accelerating gas present behind the flying body is formed into plasmas by a laser, to flow electric current from one of the inner augment rails → plasma armature → the other of the inner augment rails, and additionally accelerate the flying body by Lorentz force formed in this case. Since the plasmas are maintained in a state of higher density than the plasmas obtained by using all of the augment rails, the ignition capacitor for initial plasmas in switched to a power source. As a result, it is possible to flow the maximum current before the plasmas expand, and a large accelerating force and a high magnetic flux density are attained, to improve acceleration performance of the flying body. (N.H.)

  9. Single conversion stage amplifier - SICAM

    Energy Technology Data Exchange (ETDEWEB)

    Ljusev, P.

    2005-12-15

    This Ph.D. thesis presents a thorough analysis of the so called SICAM - SIngle Converter stage AMplifier approach to building direct energy conversion audio power amplifiers. The mainstream approach for building isolated audio power amplifiers today consists of isolated DC power supply and Class D amplifier, which essentially represents a two stage solution, where each of the components can be viewed as separate and independent part. The proposed SICAM solution strives for direct energy conversion from the mains to the audio output, by dedicating the operation of the components one to another and integrating their functions, so that the final audio power amplifier represents a single-stage topology with higher efficiency, lower volume, less board space, lower component count and subsequently lower cost. The SICAM approach is both applicable to non-isolated and isolated audio power amplifiers, but the problems encountered in these two cases are different. Non-isolated SICAM solutions are intended for both AC mains-connected and battery-powered devices. In non-isolated mains-connected SICAMs the main idea is to simplify the power supply or even provide integrated power factor correction (PFC) functions, while still maintaining low component stress and good audio performance by generally decreasing the input voltage level to the Class D audio power amplifier. On the other hand, non-isolated battery-powered SICAMs have to cope with the ever changing battery voltage and provide output voltage levels which are both lower and higher than the battery voltage, while still being simple and single-stage energy conversion solutions. In isolated SICAMs the isolation transformer adjusts the voltage level on the secondary side to the desired level, so the main challenges here are decreasing the size of the magnetic core and reducing the number and size of bulky reactive components as much as possible. The main focus of this thesis is directed towards the isolated SICAMs and

  10. Second-stage acceleration in solar flares

    International Nuclear Information System (INIS)

    Mullan, D.J.

    1976-01-01

    A model proposed by Chevalier and Scott to account for cosmic ray acceleration in an expanding supernova remnant is applied to the case of a shock wave injected into the solar corona by a flare. Certain features of solar cosmic rays can be explained by this model. (orig.) [de

  11. Flame acceleration in the early stages of burning in tubes

    Energy Technology Data Exchange (ETDEWEB)

    Bychkov, Vitaly; Fru, Gordon; Petchenko, Arkady [Institute of Physics, Umeaa University, S-901 87 Umeaa (Sweden); Akkerman, V' yacheslav [Institute of Physics, Umeaa University, S-901 87 Umeaa (Sweden); Nuclear Safety Institute (IBRAE) of Russian Academy of Sciences, B. Tulskaya 52, 115191 Moscow (Russian Federation); Eriksson, Lars-Erik [Department of Applied Mechanics, Chalmers University of Technology, 412 96 Goeteborg (Sweden)

    2007-09-15

    Acceleration of premixed laminar flames in the early stages of burning in long tubes is considered. The acceleration mechanism was suggested earlier by Clanet and Searby [Combust. Flame 105 (1996) 225]. Acceleration happens due to the initial ignition geometry at the tube axis when a flame develops to a finger-shaped front, with surface area growing exponentially in time. Flame surface area grows quite fast but only for a short time. The analytical theory of flame acceleration is developed, which determines the growth rate, the total acceleration time, and the maximal increase of the flame surface area. Direct numerical simulations of the process are performed for the complete set of combustion equations. The simulations results and the theory are in good agreement with the previous experiments. The numerical simulations also demonstrate flame deceleration, which follows acceleration, and the so-called ''tulip flames''. (author)

  12. Control of Single-Stage Single-Phase PV inverter

    DEFF Research Database (Denmark)

    Ciobotaru, Mihai; Teodorescu, Remus; Blaabjerg, Frede

    2005-01-01

    In this paper the issue of control strategies for single-stage photovoltaic (PV) inverter is addressed. Two different current controllers have been implemented and an experimental comparison between them has been made. A complete control structure for the single-phase PV system is also presented...

  13. Glass coated single grid for charged particle acceleration

    Science.gov (United States)

    Banks, B. A.; Nakanishi, S.

    1968-01-01

    Glass coating is used on a single grid accelerator system for ion thrusters. The uniformly thin, smooth, dense, impervious glass coating has a high dielectric strength and is firmly bonded to the accelerator grid.

  14. Delayed Single Stage Perineal Posterior Urethroplasty

    International Nuclear Information System (INIS)

    Ali, S.; Shahnawaz; Shahzad, I.; Baloch, M. U.

    2015-01-01

    Objective: To determine the delayed single stage perineal posterior urethroplasty for treatment of posterior urethral stricture/distraction defect. Study Design: Descriptive case series. Place and Duration of Study: Department of Urology, Jinnah Postgraduate Medical Centre, Karachi, from January 2009 to December 2011. Methodology: Patients were selected for delayed single stage perineal posterior urethroplasty for treatment of posterior urethral stricture / distraction defect. All were initially suprapubically catheterized followed by definitive surgery after at least 3 months. Results: Thirty male patients were analyzed with a mean follow-up of 10 months, 2 patients were excluded as they developed failure in first 3 months postoperatively. Mean patients age was 26.25 ± 7.9 years. On follow-up, 7 patients (23.3 percentage) experienced recurrent stricture during first 10 months. Five (16.6 percentage) patients were treated successfully with single direct visual internal urethrotomy. Two patients (6.6 percentage) had more than one direct visual internal urethrotomy and considered failed. Re-do perineal urethroplasty was eventually performed. The overall success rate was 93.3 percentage with permissive criteria allowing single direct visual internal urethrotomy and 76.6% with strict criteria allowing no more procedures postoperatively. Conclusion: Posterior anastomotic urethroplasty offers excellent long-term results to patients with posterior urethral trauma and distraction defect even after multiple prior procedures. (author)

  15. Staging of RF-accelerating Units in a MEMS-based Ion Accelerator

    Science.gov (United States)

    Persaud, A.; Seidl, P. A.; Ji, Q.; Feinberg, E.; Waldron, W. L.; Schenkel, T.; Ardanuc, S.; Vinayakumar, K. B.; Lal, A.

    Multiple Electrostatic Quadrupole Array Linear Accelerators (MEQALACs) provide an opportunity to realize compact radio- frequency (RF) accelerator structures that can deliver very high beam currents. MEQALACs have been previously realized with acceleration gap distances and beam aperture sizes of the order of centimeters. Through advances in Micro-Electro-Mechanical Systems (MEMS) fabrication, MEQALACs can now be scaled down to the sub-millimeter regime and batch processed on wafer substrates. In this paper we show first results from using three RF stages in a compact MEMS-based ion accelerator. The results presented show proof-of-concept with accelerator structures formed from printed circuit boards using a 3 × 3 beamlet arrangement and noble gas ions at 10 keV. We present a simple model to describe the measured results. We also discuss some of the scaling behaviour of a compact MEQALAC. The MEMS-based approach enables a low-cost, highly versatile accelerator covering a wide range of currents (10 μA to 100 mA) and beam energies (100 keV to several MeV). Applications include ion-beam analysis, mass spectrometry, materials processing, and at very high beam powers, plasma heating.

  16. Single-particle dynamics - RF acceleration

    International Nuclear Information System (INIS)

    Montague, B.W.

    1977-01-01

    In this paper the rf acceleration of both synchronous and non-synchronous particles is discussed and a simple linearized equation of small amplitude synchrotron oscillations is derived. Phase stability, the hamiltonian for synchrotron oscillations, oscillation amplitudes and adiabatic damping are then briefly discussed. The final sections of the paper contain a description of the basic principles of rf beam stacking in the longitudinal phase space of intersecting Storage Rings and a description of phase displacement acceleration which inspite of certain disadvantages, remains an attractive technique for proton storage rings. (B.D.)

  17. Control of Single-Stage Single-Phase PV inverter

    DEFF Research Database (Denmark)

    Ciobotaru, Mihai; Teodorescu, Remus; Blaabjerg, Frede

    2005-01-01

    In this paper the issue of control strategies for single-stage photovoltaic (PV) inverter is addressed. Two different current controllers have been implemented and an experimental comparison between them has been made. A complete control structure for the single-phase PV system is also presented......-forward; - and the grid current controller implemented in two different ways, using the classical proportional integral (PI) and the novel proportional resonant (PR) controllers. The control strategy was tested experimentally on 1.5 kW PV inverter........ The main elements of the PV control structure are: - a maximum power point tracker (MPPT) algorithm using the incremental conductance method; - a synchronization method using the phase-locked-loop (PLL), based on delay; - the input power control using the dc voltage controller and power feed...

  18. Earthquake acceleration amplification based on single microtremor test

    Science.gov (United States)

    Jaya Syahbana, Arifan; Kurniawan, Rahmat; Soebowo, Eko

    2018-02-01

    Understanding soil dynamics is needed to understand soil behaviour, including the parameters of earthquake acceleration amplification. Many researchers now conduct single microtremor tests to obtain amplification of velocity and natural periods of soil at test sites. However, these amplification parameters are rarely used, so a method is needed to convert the velocity amplification to acceleration amplification. This paper will discuss the proposed process of changing the value of amplification. The proposed method is to integrate the time histories of the synthetic earthquake acceleration of the soil surface under the deaggregation at that location so the time histories of the velocity earthquake will be obtained. Next is to conduct a “fitting curve” between amplification by a single microtremor test with amplification of the synthetic earthquake velocity time histories. After obtaining the fitting curve time histories of velocity, differentiation will be conducted to obtain fitting curve acceleration time histories. The final step after obtaining the fitting curve is to compare the acceleration of the “fitting curve” against the histories time of the acceleration of synthetic earthquake at bedrocks to obtain single microtremor acceleration amplification factor.

  19. ATOM - Accelerating Therapeutics for Opportunities in Medicine | FNLCR Staging

    Science.gov (United States)

    The Frederick National Lab is a founding member of the Accelerating Therapeutics for Opportunities in Medicine (ATOM) Consortium,a public-private partnership with themission oftransforming drug discovery by accelerating the deve

  20. Transformer ratio studies for single bunch plasma wakefield acceleration

    Energy Technology Data Exchange (ETDEWEB)

    Massimo, F., E-mail: francesco.massimo@uniroma1.it [Dipartimento SBAI, “Sapienza” University of Rome, Rome (Italy); Marocchino, A. [Dipartimento SBAI, “Sapienza” University of Rome, Rome (Italy); Chiadroni, E.; Ferrario, M. [INFN-LNF, Frascati (Italy); Mostacci, A. [Dipartimento SBAI, “Sapienza” University of Rome, Rome (Italy); INFN-LNF, Frascati (Italy); Musumeci, P. [University of California, Department of Physics and Astronomy, Los Angeles (United States); Palumbo, L. [Dipartimento SBAI, “Sapienza” University of Rome, Rome (Italy); INFN-LNF, Frascati (Italy)

    2014-03-11

    In Plasma Wakefield Acceleration (PWFA) plasma oscillations are driven by ultra relativistic electron beams. The ratio of the maximum accelerating field behind the driving beam (bunch) and the maximum decelerating field inside the driving beam (bunch) is defined as Transformer Ratio, a key parameter that determines the energy gain in particle acceleration. We investigate the transformer ratio for different shapes of a single driving bunch. One dimensional, fluid, relativistic, cold plasma equations have been numerically solved. A complete map of the transformer ratio is obtained by varying: bunch shape, bunch length and density ratio. It is found that the transformer ratio critically depends on the bunch shape and on the density ratio. Moreover both in the linear as well as in the non-linear regime the theoretical limit of 2 for the transformer ratio of a single symmetric bunch can be exceeded using asymmetric bunches in the linear regime as well as symmetric bunches in nonlinear regime.

  1. Staged electron laser accelerator (STELLA) experiment at brookhaven ATF

    Energy Technology Data Exchange (ETDEWEB)

    Pogorelsky, I.V.; Steenbergen, A. van; Gallardo, J.C. [Brookhaven National Lab., Upton, NY (United States)] [and others

    1998-03-01

    The STELLA experiment is being prepared at the BNL Accelerator Test Facility (STF). The goal of the experiment is to demonstrate quasi-monochromatic inverse Cherenkov acceleration (ICA) of electrons bunched to the laser wavelength period. Microbunches on the order of 2 {mu}m in length separated by 10.6 {mu}m will be produced using an inverse free electron laser (IFEL) accelerator driven by a CO{sub 2} laser. The design and simulations for two phases of this experiment including demonstration of 10 MeV and 100 MeV acceleration are presented. (author)

  2. European accelerator facilities for single event effects testing

    Energy Technology Data Exchange (ETDEWEB)

    Adams, L.; Nickson, R.; Harboe-Sorensen, R. [ESA-ESTEC, Noordwijk (Netherlands); Hajdas, W.; Berger, G.

    1997-03-01

    Single event effects are an important hazard to spacecraft and payloads. The advances in component technology, with shrinking dimensions and increasing complexity will give even more importance to single event effects in the future. The ground test facilities are complex and expensive and the complexities of installing a facility are compounded by the requirement that maximum control is to be exercised by users largely unfamiliar with accelerator technology. The PIF and the HIF are the result of experience gained in the field of single event effects testing and represent a unique collaboration between space technology and accelerator experts. Both facilities form an essential part of the European infrastructure supporting space projects. (J.P.N.)

  3. Staging optics considerations for a plasma wakefield acceleration linear collider

    Energy Technology Data Exchange (ETDEWEB)

    Lindstrøm, C.A., E-mail: c.a.lindstrom@fys.uio.no [Department of Physics, University of Oslo, Oslo 0316 (Norway); SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Adli, E. [Department of Physics, University of Oslo, Oslo 0316 (Norway); SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Allen, J.M.; Delahaye, J.P.; Hogan, M.J. [SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Joshi, C. [Department of Electrical Engineering, UCLA, Los Angeles, CA 90095 (United States); Muggli, P. [Max Planck Institute for Physics, 80805 Munich (Germany); Raubenheimer, T.O.; Yakimenko, V. [SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States)

    2016-09-01

    Plasma wakefield acceleration offers acceleration gradients of several GeV/m, ideal for a next-generation linear collider. The beam optics requirements between plasma cells include injection and extraction of drive beams, matching the main beam beta functions into the next cell, canceling dispersion as well as constraining bunch lengthening and chromaticity. To maintain a high effective acceleration gradient, this must be accomplished in the shortest distance possible. A working example is presented, using novel methods to correct chromaticity, as well as scaling laws for a high energy regime.

  4. Design considerations for single-stage and two-stage pneumatic pellet injectors

    International Nuclear Information System (INIS)

    Gouge, M.J.; Combs, S.K.; Fisher, P.W.; Milora, S.L.

    1988-09-01

    Performance of single-stage pneumatic pellet injectors is compared with several models for one-dimensional, compressible fluid flow. Agreement is quite good for models that reflect actual breech chamber geometry and incorporate nonideal effects such as gas friction. Several methods of improving the performance of single-stage pneumatic pellet injectors in the near term are outlined. The design and performance of two-stage pneumatic pellet injectors are discussed, and initial data from the two-stage pneumatic pellet injector test facility at Oak Ridge National Laboratory are presented. Finally, a concept for a repeating two-stage pneumatic pellet injector is described. 27 refs., 8 figs., 3 tabs

  5. DEVELOPMENT OF WATER JET PLASMA MIRROR FOR STAGING OF LASER PLASMA ACCELERATORS

    International Nuclear Information System (INIS)

    Panasenko, Dmitriy; Gonsalves, Anthony J.; Leemans, Wim; Nakamura, Kei; Shu, Anthony; Toth, Csaba

    2009-01-01

    Staging Laser Plasma Accelerators (LPAs) is necessary in order to reach beam energies of 100 GeV and above. This requires incoupling of additional laser beams into accelerating stages. In order to maintain the high average accelerating gradient of a staged LPA, it is imperative to minimize the distance that is needed for laser incoupling. A plasma mirror is proposed as the final coupling optic reducing the coupling distance from tens of meters, using a conventional optic, to as small as a few cm. Both a planar water jet and a nitrocellulose foil are used as reflecting surfacesand characterized. A maximum reflectivity of 70percent was obtained using both surfaces.

  6. Single-stage repair versus traditional repair of high anorectal ...

    African Journals Online (AJOL)

    random number table. The patients in group A were treated with a single-stage operation, whereas the patients in group B were treated with a standard staged operation. (either PSARP or abdominoperineal pull-through). After clinical evaluation using the Kelly score, patients were divided into three clinical groups ...

  7. Systems and methods for cylindrical hall thrusters with independently controllable ionization and acceleration stages

    Science.gov (United States)

    Diamant, Kevin David; Raitses, Yevgeny; Fisch, Nathaniel Joseph

    2014-05-13

    Systems and methods may be provided for cylindrical Hall thrusters with independently controllable ionization and acceleration stages. The systems and methods may include a cylindrical channel having a center axial direction, a gas inlet for directing ionizable gas to an ionization section of the cylindrical channel, an ionization device that ionizes at least a portion of the ionizable gas within the ionization section to generate ionized gas, and an acceleration device distinct from the ionization device. The acceleration device may provide an axial electric field for an acceleration section of the cylindrical channel to accelerate the ionized gas through the acceleration section, where the axial electric field has an axial direction in relation to the center axial direction. The ionization section and the acceleration section of the cylindrical channel may be substantially non-overlapping.

  8. Design, Construction and Measured Performance of a Single-Stage ...

    African Journals Online (AJOL)

    The design philosophy, construction and measured performances of a single stage, single entry centrifugal pump demonstration unit are presented. In the construction, close-coupled induction motor drives the centrifugal pump, which draws fluid (water) from a water storage tank and delivers same through a flow control ...

  9. Single-pulse electrons from a linear accelerator

    International Nuclear Information System (INIS)

    Antoku, Shigetoshi; Sunayashiki, Tadashi; Takeoka, Seiji; Kato, Kazushi

    1976-01-01

    The electronic circuits of a 35 MeV linear accelerator at Hiroshima University were modified to produce single-pulse electrons. Single-pulse electrons were obtained by synchronizing one of eight pulses from an electron gun modulator, 120 pps, to one of the micro-waves from a klystron, 15 pps. After single-pulse electrons were discharged, a signal was relayed to a stop-gate circuit from a binary scaler which was connected to the gun modulator. Although reproducibility of single-pulse electrons and stability of electron output per pulse were not completely satisfactory, it was possible to use for radiobiological studies. Biological effects of single-pulse electrons (energy: 25 MeV, dose rate: 10 10 rad/min) on cultured mammalian cells and on mice were nearly equal to those of multi-pulse electrons (25 MeV, 10 7 rad/min) and Co-60 γ-rays (dose rate: 100 rad/min). (auth.)

  10. Comparison between a two-stage and single-stage digesters when ...

    African Journals Online (AJOL)

    Phenol is a pollutant found in many industrial wastewaters, which diminishes biogas formation in anaerobic digesters. In this study, a two-stage (acidogenic and methanogenic) anaerobic digester (TSAD) was compared to a single stage digester (SSD), in treating a synthetic wastewater contaminated with phenol.

  11. Accelerated Monte Carlo simulation on the chemical stage in water radiolysis using GPU

    Science.gov (United States)

    Tian, Zhen; Jiang, Steve B.; Jia, Xun

    2017-04-01

    The accurate simulation of water radiolysis is an important step to understand the mechanisms of radiobiology and quantitatively test some hypotheses regarding radiobiological effects. However, the simulation of water radiolysis is highly time consuming, taking hours or even days to be completed by a conventional CPU processor. This time limitation hinders cell-level simulations for a number of research studies. We recently initiated efforts to develop gMicroMC, a GPU-based fast microscopic MC simulation package for water radiolysis. The first step of this project focused on accelerating the simulation of the chemical stage, the most time consuming stage in the entire water radiolysis process. A GPU-friendly parallelization strategy was designed to address the highly correlated many-body simulation problem caused by the mutual competitive chemical reactions between the radiolytic molecules. Two cases were tested, using a 750 keV electron and a 5 MeV proton incident in pure water, respectively. The time-dependent yields of all the radiolytic species during the chemical stage were used to evaluate the accuracy of the simulation. The relative differences between our simulation and the Geant4-DNA simulation were on average 5.3% and 4.4% for the two cases. Our package, executed on an Nvidia Titan black GPU card, successfully completed the chemical stage simulation of the two cases within 599.2 s and 489.0 s. As compared with Geant4-DNA that was executed on an Intel i7-5500U CPU processor and needed 28.6 h and 26.8 h for the two cases using a single CPU core, our package achieved a speed-up factor of 171.1-197.2.

  12. Comparisons of single-stage and two-stage approaches to genomic selection.

    Science.gov (United States)

    Schulz-Streeck, Torben; Ogutu, Joseph O; Piepho, Hans-Peter

    2013-01-01

    Genomic selection (GS) is a method for predicting breeding values of plants or animals using many molecular markers that is commonly implemented in two stages. In plant breeding the first stage usually involves computation of adjusted means for genotypes which are then used to predict genomic breeding values in the second stage. We compared two classical stage-wise approaches, which either ignore or approximate correlations among the means by a diagonal matrix, and a new method, to a single-stage analysis for GS using ridge regression best linear unbiased prediction (RR-BLUP). The new stage-wise method rotates (orthogonalizes) the adjusted means from the first stage before submitting them to the second stage. This makes the errors approximately independently and identically normally distributed, which is a prerequisite for many procedures that are potentially useful for GS such as machine learning methods (e.g. boosting) and regularized regression methods (e.g. lasso). This is illustrated in this paper using componentwise boosting. The componentwise boosting method minimizes squared error loss using least squares and iteratively and automatically selects markers that are most predictive of genomic breeding values. Results are compared with those of RR-BLUP using fivefold cross-validation. The new stage-wise approach with rotated means was slightly more similar to the single-stage analysis than the classical two-stage approaches based on non-rotated means for two unbalanced datasets. This suggests that rotation is a worthwhile pre-processing step in GS for the two-stage approaches for unbalanced datasets. Moreover, the predictive accuracy of stage-wise RR-BLUP was higher (5.0-6.1%) than that of componentwise boosting.

  13. Stochastic acceleration by a single wave in a magnetized plasma

    Energy Technology Data Exchange (ETDEWEB)

    Smith, R.

    1977-09-22

    A particularly simple problem exhibiting stochasticity is the motion of a charged particle in a uniform magnetic field and a single wave. Detailed studies of this wave-particle interaction show the following features. An electrostatic wave propagating obliquely to the magnetic field causes stochastic motion if the wave amplitude exceeds a certain threshold. The overlap of cyclotron resonances then destroys a constant of the motion, allowing strong particle acceleration. A wave of large enough amplitude would thus suffer severe damping and lead to rapid heating of a particle distribution. The stochastic motion resembles a diffusion process even though the wave spectrum contains only a single wave. The motion of ions in a nonuniform magnetic field and a single electrostatic wave is treated in our study of a possible saturation mechanism of the dissipative trapped-ion instability in a tokamak. A theory involving the overlap of bounce resonances predicts the main features found in the numerical integration of the equations of motion. Ions in a layer near the trapped-circulating boundary move stochastically. This motion leads to nonlinear stabilization mechanisms which are described qualitatively.

  14. Beam dynamics analysis of femtosecond microbunches produced by the staged electron laser acceleration experiment

    Directory of Open Access Journals (Sweden)

    F. Zhou

    2003-05-01

    Full Text Available Preservation of the femtosecond (fs microbunches, created during laser acceleration, is a crucial step to enable staging of the laser acceleration process. This paper focuses on the optimization of the beam dynamics of fs microbunches transported through the staged electron laser acceleration (STELLA-II experiment being carried out at the Brookhaven National Laboratory Accelerator Test Facility. STELLA-II consists of an inverse free electron laser (IFEL untapered undulator, which acts as an electron beam energy modulator; a magnetic chicane, which acts as a buncher; a second IFEL tapered undulator, which acts as an accelerator; and a dipole, which serves as an energy spectrometer. When the energy-modulated macrobunch traverses through the chicane and a short drift space, microbunches of order fs in duration (i.e., ∼3  fs FWHM are formed. The 3-fs microbunches are accelerated by interacting with a high-power CO_{2} laser beam in the following tapered undulator. These extremely short microbunches may experience significant space charge and coherent synchrotron radiation effects when traversing the STELLA-II transport line. These effects are analyzed and the safe operating conditions are determined. With less than 0.5-pC microbunch charge, both microbunch debunching and emittance growth are negligible, and the energy-spread increase is less than 5%. These results are also useful for the laser electron acceleration project at SLAC and in possible future programs where the fs microbunches are employed for other purposes.

  15. Single particle dynamics and nonlinear resonances in circular accelerators

    International Nuclear Information System (INIS)

    Ruth, R.D.

    1985-11-01

    The purpose of this paper is to introduce the reader to single particle dynamics in circular accelerators with an emphasis on nonlinear resonances. We begin with the Hamiltonian and the equations of motion in the neighborhood of the design orbit. In the linear theory this yields linear betatron oscillations about a closed orbit. It is useful then to introduce the action-angle variables of the linear problem. Next we discuss the nonlinear terms which are present in an actual accelerator, and in particular, we motivate the inclusion of sextupoles to cure chromatic effects. To study the effects of the nonlinear terms, we next discuss canonical perturbation theory which leads us to nonlinear resonances. After showing a few examples of perturbation theory, we abandon it when very close to a resonance. This leads to the study of an isolated resonance in one degree of freedom with a 'time'-dependent Hamiltonian. We see the familiar resonance structure in phase space which is simply closed islands when the nonlinear amplitude dependence of the frequency or 'tune' is included. To show the limits of the validity of the isolated resonance approximation, we discuss two criteria for the onset of chaotic motion. Finally, we study an isolated coupling resonance in two degrees of freedom with a 'time'-dependent Hamiltonian and calculate the two invariants in this case. This leads to a surface of section which is a 2-torus in 4-dimensional phase space. However, we show that it remains a 2-torus when projected into particular 3-dimensional subspaces, and thus can be viewed in perspective

  16. Construction of a 300-keV compact ion microbeam system with a three-stage acceleration lens

    Energy Technology Data Exchange (ETDEWEB)

    Ishii, Yasuyuki, E-mail: ishii.yasuyuki@jaea.go.jp; Ohkubo, Takeru; Kojima, Takuji; Kamiya, Tomihiro

    2014-08-01

    Hydrogen ion microbeams were experimentally formed at beam energies below 150 keV using a 300-keV compact microbeam system that was constructed at the Japan Atomic Energy Agency. This paper is a preliminary report on the performance of the three-stage acceleration lens used in the compact microbeam system. This system consists of a three-stage acceleration lens and a plasma-type ion source. Since the three-stage acceleration lens was designed to simultaneously accelerate and focus the ion beam, the compact microbeam system is only about 1-m high and can be placed in a small experimental room. To evaluate the effectiveness of the three-stage acceleration lens, experimentally measured beam sizes are compared with theoretically calculated ones. The calculated and measured beam sizes were consistent within 10%. This shows that the three-stage acceleration lens is effective as a focusing lens for forming microbeams.

  17. An accelerated hypofractionated radiotherapy regimen in patients after organ-sparing surgery for stages I–IIA breast cancer

    Directory of Open Access Journals (Sweden)

    I. A. Gladilina

    2016-01-01

    Full Text Available Objective: to assess the results of accelerated hypofractionated radiotherapy and to comparatively analyze it with the standard radiotherapy in patients with stages I–IIA breast cancer (BC after organ-sparing surgery.Materials and methods. A total of 203 patients with stages I–IIA BC underwent radiotherapy after organ-sparing surgery. A control group of 91 patients received the standard radiotherapy (the single focal dose (SFD was 2 Gy 5 times a week, 25 fractions; the total focal dose (TFD was 50 Gy for 5 weeks. A study group of 112 patients had accelerated hypofractionated radiotherapy (SFD 3 Gy 5 times a week, 13 fractions; TFD 39 Gy for 2.3 weeks.Results. Local recurrences were not detected in any patient after the hypofractionated radiotherapy regimen and were diagnosed in 3.3 % of the patients after the standard regimen. There were no statistically significant differences between the groups in 5-year overall and relapsefree survival rates. Further observation revealed a statistically significant difference in 6-year overall survival rates in the study and control groups: 99.1 and 70.4 %, respectively (p ≤ 0.046. The 6-year relapse-free survival rates in patients who had received the accelerated hypo-fractionated radiotherapy regimen were also significantly higher than in those who had the standard radiotherapy regimen: 97.9 and 71.3 %, respectively (p ≤ 0.043. The rate of post-radiation normal tissue damages after the hypofractionated radiotherapy regimen was significantly lower (15.2 % than that after the standard regimen (27.5 %. Good and excellent cosmetic results of treatment were achieved in most (95.1 % patients and did not differ in their frequency after different radiotherapy regimens.Conclusion. The accelerated hypofractionated radiotherapy regimen showed a high efficiency and a favorable toxicity profile in patients with stages I–IIA BC.

  18. A single-beam deuteron compact accelerator for neutron generation

    International Nuclear Information System (INIS)

    Araujo, Wagner Leite; Campos, Tarcisio Passos Ribeiro de

    2011-01-01

    Portable neutron generators are devices composed by small size accelerators that produce neutrons through fusion between hydrogen isotopes. These reactions are characterized by appreciable cross section at energies at the tens of keV, which enables device portability. The project baselines follow the same physical and engineering principles of any other particle accelerators. The generator consists of a gas reservoir, apparatus for ion production, few electrodes to accelerate and focus the ion beam, and a metal hydride target where fusion reactions occur. Neutron generator applications include geophysical measurements, indus- trial process control, environmental, research, nation's security and mechanical structure analysis.This article presents a design of a compact accelerator for d-d neutron generators, describing the physical theory applied to the deuteron extraction system, and simulating the ion beam transport in the accelerator. (author)

  19. Evaluation of an automated single-channel sleep staging algorithm

    Science.gov (United States)

    Wang, Ying; Loparo, Kenneth A; Kelly, Monica R; Kaplan, Richard F

    2015-01-01

    Background We previously published the performance evaluation of an automated electroencephalography (EEG)-based single-channel sleep–wake detection algorithm called Z-ALG used by the Zmachine® sleep monitoring system. The objective of this paper is to evaluate the performance of a new algorithm called Z-PLUS, which further differentiates sleep as detected by Z-ALG into Light Sleep, Deep Sleep, and Rapid Eye Movement (REM) Sleep, against laboratory polysomnography (PSG) using a consensus of expert visual scorers. Methods Single night, in-lab PSG recordings from 99 subjects (52F/47M, 18–60 years, median age 32.7 years), including both normal sleepers and those reporting a variety of sleep complaints consistent with chronic insomnia, sleep apnea, and restless leg syndrome, as well as those taking selective serotonin reuptake inhibitor/serotonin–norepinephrine reuptake inhibitor antidepressant medications, previously evaluated using Z-ALG were re-examined using Z-PLUS. EEG data collected from electrodes placed at the differential-mastoids (A1–A2) were processed by Z-ALG to determine wake and sleep, then those epochs detected as sleep were further processed by Z-PLUS to differentiate into Light Sleep, Deep Sleep, and REM. EEG data were visually scored by multiple certified polysomnographic technologists according to the Rechtschaffen and Kales criterion, and then combined using a majority-voting rule to create a PSG Consensus score file for each of the 99 subjects. Z-PLUS output was compared to the PSG Consensus score files for both epoch-by-epoch (eg, sensitivity, specificity, and kappa) and sleep stage-related statistics (eg, Latency to Deep Sleep, Latency to REM, Total Deep Sleep, and Total REM). Results Sensitivities of Z-PLUS compared to the PSG Consensus were 0.84 for Light Sleep, 0.74 for Deep Sleep, and 0.72 for REM. Similarly, positive predictive values were 0.85 for Light Sleep, 0.78 for Deep Sleep, and 0.73 for REM. Overall, kappa agreement of 0

  20. Single Stage Contactor Testing Of The Next Generation Solvent Blend

    Energy Technology Data Exchange (ETDEWEB)

    Herman, D. T.; Peters, T. B.; Duignan, M. R.; Williams, M. R.; Poirier, M. R.; Brass, E. A.; Garrison, A. G.; Ketusky, E. T.

    2014-01-06

    The Modular Caustic Side Solvent Extraction (CSSX) Unit (MCU) facility at the Savannah River Site (SRS) is actively pursuing the transition from the current BOBCalixC6 based solvent to the Next Generation Solvent (NGS)-MCU solvent to increase the cesium decontamination factor. To support this integration of NGS into the MCU facility the Savannah River National Laboratory (SRNL) performed testing of a blend of the NGS (MaxCalix based solvent) with the current solvent (BOBCalixC6 based solvent) for the removal of cesium (Cs) from the liquid salt waste stream. This testing utilized a blend of BOBCalixC6 based solvent and the NGS with the new extractant, MaxCalix, as well as a new suppressor, tris(3,7dimethyloctyl) guanidine. Single stage tests were conducted using the full size V-05 and V-10 liquid-to-liquid centrifugal contactors installed at SRNL. These tests were designed to determine the mass transfer and hydraulic characteristics with the NGS solvent blended with the projected heel of the BOBCalixC6 based solvent that will exist in MCU at time of transition. The test program evaluated the amount of organic carryover and the droplet size of the organic carryover phases using several analytical methods. The results indicate that hydraulically, the NGS solvent performed hydraulically similar to the current solvent which was expected. For the organic carryover 93% of the solvent is predicted to be recovered from the stripping operation and 96% from the extraction operation. As for the mass transfer, the NGS solvent significantly improved the cesium DF by at least an order of magnitude when extrapolating the One-stage results to actual Seven-stage extraction operation with a stage efficiency of 95%.

  1. Comparison of single-stage and temperature-phased two-stage anaerobic digestion of oily food waste

    International Nuclear Information System (INIS)

    Wu, Li-Jie; Kobayashi, Takuro; Li, Yu-You; Xu, Kai-Qin

    2015-01-01

    Highlights: • A single-stage and two two-stage anaerobic systems were synchronously operated. • Similar methane production 0.44 L/g VS added from oily food waste was achieved. • The first stage of the two-stage process became inefficient due to serious pH drop. • Recycle favored the hythan production in the two-stage digestion. • The conversion of unsaturated fatty acids was enhanced by recycle introduction. - Abstract: Anaerobic digestion is an effective technology to recover energy from oily food waste. A single-stage system and temperature-phased two-stage systems with and without recycle for anaerobic digestion of oily food waste were constructed to compare the operation performances. The synchronous operation indicated the similar ability to produce methane in the three systems, with a methane yield of 0.44 L/g VS added . The pH drop to less than 4.0 in the first stage of two-stage system without recycle resulted in poor hydrolysis, and methane or hydrogen was not produced in this stage. Alkalinity supplement from the second stage of two-stage system with recycle improved pH in the first stage to 5.4. Consequently, 35.3% of the particulate COD in the influent was reduced in the first stage of two-stage system with recycle according to a COD mass balance, and hydrogen was produced with a percentage of 31.7%, accordingly. Similar solids and organic matter were removed in the single-stage system and two-stage system without recycle. More lipid degradation and the conversion of long-chain fatty acids were achieved in the single-stage system. Recycling was proved to be effective in promoting the conversion of unsaturated long-chain fatty acids into saturated fatty acids in the two-stage system.

  2. New results for single stage low energy carbon AMS

    International Nuclear Information System (INIS)

    Klody, G.M.; Schroeder, J.B.; Norton, G.A.; Loger, R.L.; Kitchen, R.L.; Sundquist, M.L.

    2005-01-01

    A new configuration of the NEC single stage, low energy carbon AMS system (U.S. Patent 6,815,666 B2) has been built and tested. The injector includes two 40-sample ion sources, electrostatic and magnetic analysis, and fast sequential injection. The gas stripper, analyzing magnet, electrostatic analyzer, and detector are on an open air 250 kV deck. Both 12 C and 13 C currents are measured on the deck after the stripper, and an SSB detector is used for 14 C counting. Injected 12 C and mass 13 ( 13 C and 12 CH) currents are also measured. Automated controls follow a user-specified run list for unattended operation. Initial test results show precision for 14 C/ 12 C ratios of better than 5 per mil, and backgrounds for unprocessed graphite of less than 0.005 x modern. We will report final results for precision, background, and throughput and discuss related design features

  3. Compressed gas combined single- and two-stage light-gas gun

    Science.gov (United States)

    Lamberson, L. E.; Boettcher, P. A.

    2018-02-01

    With more than 1 trillion artificial objects smaller than 1 μm in low and geostationary Earth orbit, space assets are subject to the constant threat of space debris impact. These collisions occur at hypervelocity or speeds greater than 3 km/s. In order to characterize material behavior under this extreme event as well as study next-generation materials for space exploration, this paper presents a unique two-stage light-gas gun capable of replicating hypervelocity impacts. While a limited number of these types of facilities exist, they typically are extremely large and can be costly and dangerous to operate. The design presented in this paper is novel in two distinct ways. First, it does not use a form of combustion in the first stage. The projectile is accelerated from a pressure differential using air and inert gases (or purely inert gases), firing a projectile in a nominal range of 1-4 km/s. Second, the design is modular in that the first stage sits on a track sled and can be pulled back and used in itself to study lower speed impacts without any further modifications, with the first stage piston as the impactor. The modularity of the instrument allows the ability to investigate three orders of magnitude of impact velocities or between 101 and 103 m/s in a single, relatively small, cost effective instrument.

  4. The destruction of parasitic resistant stages in sewage sludge by irradiation with low accelerating voltage electrons

    International Nuclear Information System (INIS)

    Enigk, K.; Holl, P.; Dey-Hazra, A.; Polymer-Physik G.m.b.H. und Co. K.G., Tuebingen

    1975-01-01

    The destroying effect of ionizing radiation on parasitic resistant stages in sludge has been tested. Suitable for that process is an electron beam accelerator which will be provided with energy from the electric power supply network which can be switched on and off according to the requirements. Such modern utilities have an enormous beam capacity and a high operating safety. The process is working according to the continuous flow principle and at room temperature. In a series of 13 experiments the effect of different doses has been tested. A dose of 480 kRad (accelerating voltage: 400 kV, beam current: 10 mA , irradiation time: 24 sec.) can easily obtained in practical work and is economically acceptable. By these means approximately 97% of the following parasitic stages have been destroyed: undeveloped eggs of Ascaris suum, Trichuris suis, Fasciola hepatica and gastrointestinal strongylids of pigs, embryonated eggs of Capillaria obsignata and probably of Taenia spec. A few third-stage larvae of Oesophagostomum (Strongylidae) of pigs survived even 108 sec of irradiation; however, they did not develop to maturity in the definitive host. Approximately 25% of the sporulated oocysts of Eimeria tenella were still infective after 108 sec of irradiation. (orig.) [de

  5. 85,000-GPM, single-stage, single-suction LMFBR intermediate centrifugal pump

    International Nuclear Information System (INIS)

    Fair, C.E.; Cook, M.E.; Huber, K.A.; Rohde, R.

    1983-01-01

    The mechanical and hydraulic design features of the 85,000-gpm, single-stage, single-suction pump test article, which is designed to circulate liquid-sodium coolant in the intermediate heat-transport system of a Large-Scale Liquid Metal Fast Breeder Reactor (LS-LMFBR), are described. The design and analytical considerations used to satisfy the pump performance and operability requirements are presented. The validation of pump hydraulic performance using a hydraulic scale-model pump is discussed, as is the featute test for the mechanical-shaft seal system

  6. System and method for single-phase, single-stage grid-interactive inverter

    Science.gov (United States)

    Liu, Liming; Li, Hui

    2015-09-01

    The present invention provides for the integration of distributed renewable energy sources/storages utilizing a cascaded DC-AC inverter, thereby eliminating the need for a DC-DC converter. The ability to segment the energy sources and energy storages improves the maintenance capability and system reliability of the distributed generation system, as well as achieve wide range reactive power compensation. In the absence of a DC-DC converter, single stage energy conversion can be achieved to enhance energy conversion efficiency.

  7. Two-stage unilateral versus one-stage bilateral single-port sympathectomy for palmar and axillary hyperhidrosis†

    Science.gov (United States)

    Ibrahim, Mohsen; Menna, Cecilia; Andreetti, Claudio; Ciccone, Anna Maria; D'Andrilli, Antonio; Maurizi, Giulio; Poggi, Camilla; Vanni, Camilla; Venuta, Federico; Rendina, Erino Angelo

    2013-01-01

    OBJECTIVES Video-assisted thoracoscopic sympathectomy is currently the best treatment for palmar and axillary hyperhidrosis. It can be performed through either one or two stages of surgery. This study aimed to evaluate the operative and postoperative results of two-stage unilateral vs one-stage bilateral thoracoscopic sympathectomy. METHODS From November 1995 to February 2011, 270 patients with severe palmar and/or axillary hyperhidrosis were recruited for this study. One hundred and thirty patients received one-stage bilateral, single-port video-assisted thoracoscopic sympathectomy (one-stage group) and 140, two-stage unilateral, single-port video-assisted thoracoscopic sympathectomy, with a mean time interval of 4 months between the procedures (two-stage group). RESULTS The mean postoperative follow-up period was 12.5 (range: 1–24 months). After surgery, hands and axillae of all patients were dry and warm. Sixteen (12%) patients of the one-stage group and 15 (11%) of the two-stage group suffered from mild/moderate pain (P = 0.8482). The mean operative time was 38 ± 5 min in the one-stage group and 39 ± 8 min in the two-stage group (P = 0.199). Pneumothorax occurred in 8 (6%) patients of the one-stage group and in 11 (8%) of the two-stage group. Compensatory sweating occurred in 25 (19%) patients of the one-stage group and in 6 (4%) of the two-stage group (P = 0.0001). No patients developed Horner's syndrome. CONCLUSIONS Both two-stage unilateral and one-stage bilateral single-port video-assisted thoracoscopic sympathectomies are effective, safe and minimally invasive procedures. Two-stage unilateral sympathectomy can be performed with a lower occurrence of compensatory sweating, improving permanently the quality of life in patients with palmar and axillary hyperhidrosis. PMID:23442937

  8. Two-stage acceleration of an ion beam for high power ion source

    International Nuclear Information System (INIS)

    Ohara, Yoshihiro

    1979-07-01

    In research and development of a high power ion source for the JT-60 neutral beam injector, beam optics in the two-stage acceleration system has been investigated both numerically and experimentally. A computer code for cylindrically symmetric ion beam was developed for the simulation. By making use of this code, behaviour of the two-stage ion beam optics was clarified. The calculation results agreed well with the experimental ones. Experimentally, the gradient grid current and the grid heat loading proved to depend largely on the beam optics. The beam focusing by aperture displacement was investigated in thin lens approximation. The results obtained contributed to design and development of a high power ion source for the JT-60 neutral beam injector. (author)

  9. NASA Glenn's Single-Stage Axial Compressor Facility Upgraded

    Science.gov (United States)

    Brokopp, Richard A.

    2004-01-01

    NASA Glenn Research Center's Single-Stage Axial Compressor Facility was upgraded in fiscal year 2003 to expand and improve its research capabilities for testing high-speed fans and compressors. The old 3000-hp drive motor and gearbox were removed and replaced with a refurbished 7000-hp drive motor and gearbox, with a maximum output speed of 21,240 rpm. The higher horsepower rating permits testing of fans and compressors with higher pressure ratio or higher flow. A new inline torquemeter was installed to provide an alternate measurement of fan and compressor efficiency, along with the standard pressure and temperature measurements. A refurbished compressor bearing housing was also installed with bidirectional rotation capability, so that a variety of existing hardware could be tested. Four new lubrication modules with backup capability were installed for the motor, gearbox, torquemeter, and compressor bearing housing, so that in case the primary pump fails, the backup will prevent damage to the rotating hardware. The combustion air supply line for the facility inlet air system was activated to provide dry air for repeatable inlet conditions. New flow conditioning hardware was installed in the facility inlet plenum tank, which greatly reduced the inlet turbulence. The new inlet can also be easily modified to accommodate 20- or 22-in.-diameter fans and compressors, so a variety of existing hardware from other facilities (such as Glenn's 9- by 15-Foot Low-Speed Wind Tunnel) can be tested in the Single-Stage Axial Compressor Facility. An exhaust line was also installed to provide bleed capability to remove the inlet boundary layer. To improve the operation and control of the facility, a new programmable logic controller (PLC) was installed to upgrade from hardwired relay logic to software logic. The PLC also enabled the usage of human-machine interface software to allow for easier operation of the facility and easier reconfiguration of the facility controls when

  10. The Integrity of ACSR Full Tension Single-Stage Splice Connector at Higher Operation Temperature

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jy-An John [ORNL; Lara-Curzio, Edgar [ORNL; King Jr, Thomas J [ORNL

    2008-10-01

    Due to increases in power demand and limited investment in new infrastructure, existing overhead power transmission lines often need to operate at temperatures higher than those used for the original design criteria. This has led to the accelerated aging and degradation of splice connectors. It is manifested by the formation of hot-spots that have been revealed by infrared imaging during inspection. The implications of connector aging is two-fold: (1) significant increases in resistivity of the splice connector (i.e., less efficient transmission of electricity) and (2) significant reductions in the connector clamping strength, which could ultimately result in separation of the power transmission line at the joint. Therefore, the splice connector appears to be the weakest link in electric power transmission lines. This report presents a protocol for integrating analytical and experimental approaches to evaluate the integrity of full tension single-stage splice connector assemblies and the associated effective lifetime at high operating temperature.

  11. Single event simulation for memories using accelerated ions

    International Nuclear Information System (INIS)

    Sakagawa, Y.; Shiono, N.; Mizusawa, T.; Sekiguchi, M.; Sato, K.; Sugai, I.; Hirao, Y.; Nishimura, J.; Hattori, T.

    1987-01-01

    To evaluate the error immunity of the LSI memories from cosmic rays in space, an irradiation test using accelerated heavy ions is performed. The sensitive regions for 64 K DRAM (Dynamic Random Access Memory) and 4 K SRAM (Static Random Access Memory) are determined from the irradiation test results and the design parameters of the devices. The observed errors can be classified into two types. One is the direct ionization type and the other is the recoil produced error type. Sensitive region is determined for the devices. Error rate estimation methods for both types are proposed and applied to those memories used in space. The error rate of direct ionization exceeds the recoil type by 2 or 3 orders. And the direct ionization is susceptible to shield thickness. (author)

  12. Secondary malignancies in patients with stage IA-IIIA Hodgkin's lymphoma after radiation (chemoradiation) therapy using accelerated dose fractionation

    International Nuclear Information System (INIS)

    Sinajko, V.V.; Minajlo, I.I.; Veyakin, I.V.

    2010-01-01

    The incidence of secondary malignancies was investigated in 367 patients with stage IA-IIIA Hodgkin's lymphoma after radiation therapy using accelerated fractionation. For 20 years of the observation 24 of them developed 27(7.4%) tumors, besides their frequency did not depend on the disease stage and method of treatment.

  13. Single-stage mass spectrometric analyses of resin bead samples

    Energy Technology Data Exchange (ETDEWEB)

    Smith, D. H.; Walker, R. L.; Bertram, L. K.; Carter, J. A.

    1978-10-01

    Plutonium and uranium from dissolver solutions loaded on resin beads can be analyzed on single-stage mass spectrometers with little or no degradation of results provided proper care is exercised with regard to sample handling techniques. Additionally, storage of samples on resin beads is feasible for periods at least as long as six months provided the beads are not exposed to residual HNO/sub 3/ and air; it is probable that beads will retain their integrity much longer than six months when stored under collodion, but as yet no data to support this contention have been collected. Conventional or commercial mass spectrometers can readily be adapted to the resin bead technique by installing a pulse-counting detection system. The cost of such conversion will vary depending on whether or not a data acquisition system will be needed. A reasonable estimate is that the cost will be in the neighborhood of $15,000; this figure includes the price of a multi-channel analyzer to serve as a temporary data storage device, but does not include the cost of a computer. It does not appear that it will be practicable to switch easily back and forth between pulse-counting and current integration modes unless the instrument is provided with a movable Faraday cup. Using the same multiplier in both modes would undoubtedly degrade its performance in each. The requirements of low background counting rates and high gain for pulse counting, and of relatively high signal handling capacity in current integration are mutually incompatible if demanded of the same multiplier.

  14. Realization of single-phase single-stage grid-connected PV system

    Directory of Open Access Journals (Sweden)

    Osama M. Arafa

    2017-05-01

    Full Text Available This paper presents a single phase single stage grid-tied PV system. Grid angle detection is introduced to allow operation at any arbitrary power factor but unity power factor is chosen to utilize the full inverter capacity. The system ensures MPPT using the incremental conductance method and it can track the changes in insolation level without oscillations. A PI voltage controller and a dead-beat current controller are used to ensure high quality injected current to the grid. The paper investigates the system structure and performance through numerical simulation using Matlab/Simulink. An experimental setup controlled by the MicrolabBox DSP prototyping platform is utilized to realize the system and study its performance. The precautions for smooth and safe system operation including the startup sequence are fully considered in the implementation.

  15. Two-stage IMZ implants and ITI implants inserted in a single-stage procedure : A prospective comparative study

    NARCIS (Netherlands)

    Heydenrijk, Kees; Raghoebar, Gerry M.; Meijer, Henny J.A.; Reijden, Willy A. van der; Winkelhoff, Arie Jan van; Stegenga, Boudewijn

    2002-01-01

    The aim of this study was to evaluate the feasibility of using a two-stage implant system in a single-stage procedure and to study the impact of the microgap at crestal level and to monitor the microflora in the peri-implant area. Forty edentulous patients (Cawood & Howell class V–VI) participated

  16. Two-stage IMZ implants and ITI implants inserted in a single-stage procedure - A prospective comparative study

    NARCIS (Netherlands)

    Heydenrijk, K; Raghoebar, GM; Meijer, HJA; van der Reijden, WA; van Winkelhoff, AJ; Stegenga, B

    The aim of this study was to evaluate the feasibility of using a two-stage implant system in a single-stage procedure and to study the impact of the microgap at crestal level and to monitor the microflora in the peri-implant area. Forty edentulous patients (Cawood & Howell class V-VI) participated

  17. Accelerated Hypofractionated Radiotherapy for Early-Stage Non-Small-Cell Lung Cancer: Long-Term Results

    International Nuclear Information System (INIS)

    Soliman, Hany; Cheung, Patrick; Yeung, Latifa; Poon, Ian; Balogh, Judith; Barbera, Lisa; Spayne, Jacqueline; Danjoux, Cyril; Dahele, Max; Ung, Yee

    2011-01-01

    Purpose: To retrospectively review the results of a single-institution series of accelerated hypofractionated radiotherapy for early-stage non-small-cell lung cancer (NSCLC) in patients who are medically inoperable or who refuse surgery. Methods and Materials: Peripherally located T1 to T3 N0 M0 tumors were treated with 48 to 60 Gy in 12 to 15 fractions between 1996 and 2007. No elective nodal irradiation was delivered. Patient, tumor, and treatment information was abstracted from the medical records. Results: A total of 124 tumors were treated in 118 patients (56 male and 62 female). Median age at diagnosis was 76.3 years (range, 49-90 years). In all, 113 patients (95.8%) were not surgical candidates because of medical comorbidities. The 2- and 5-year overall survival (OS) rates were 51.0% and 23.3%, respectively, and the 2- and 5-year cause-specific survival (CSS) rates were 67.6% and 59.8%, respectively. The 2- and 5-year actuarial local control (LC) rates were 76.2% and 70.1%, respectively. Univariate analysis revealed that tumor size less than 3cm compared with greater than 3 cm resulted in significantly improved OS (40.0% vs. 5.0% at 5 years; p = 0.0002), CSS (69.7% vs. 45.1% at 5 years; p = 0.0461), and a trend toward better LC (82.5% vs. 66.9% at 2 years, 76.6% vs. 60.8% at 5 years; p = 0.0685). Treatment was well tolerated and there were no treatment delays because of acute toxicity. Conclusions: Accelerated hypofractionated radiotherapy with 48 to 60 Gy using fractions of 4 Gy per day provides very good results for small tumors in medically inoperable patients with early-stage NSCLC.

  18. Construction and characterization of a single stage dual diaphragm gas gun

    Science.gov (United States)

    Helminiak, Nathaniel Steven

    In the interest of studying the propagation of shock waves, this work sets out to design, construct, and characterize a pneumatic accelerator that performs high-velocity flyer plate impact tests. A single stage gas gun with a dual diaphragm breach allows for a non-volatile, reliable experimental testing platform for shock phenomena. This remotely operated gas gun utilizes compressed nitrogen to launch projectiles down a 14 foot long, 2 inch diameter bore barrel, which subsequently impacts a target material of interest. A dual diaphragm firing mechanism allows the 4.5 liter breech to reach a total pressure differential of 10ksi before accelerating projectiles to velocities as high as 1,000 m/s (1570-2240 mph). The projectile's velocity is measured using a series of break pin circuits. The target response can be measured with Photon Doppler Velocimetry (PDV) and/or stress gauge system. A vacuum system eliminates the need for pressure relief in front of the projectile, while additionally allowing the system to remain closed over the entire firing cycle. Characterization of the system will allow for projectile speed to be estimated prior to launching based on initial breach pressure.

  19. Thermodynamic analysis of single-stage and multi-stage adsorption refrigeration cycles with activated carbon–ammonia working pair

    International Nuclear Information System (INIS)

    Xu, S.Z.; Wang, L.W.; Wang, R.Z.

    2016-01-01

    Highlights: • Activated carbon–ammonia multi-stage adsorption refrigerator was analyzed. • COP, exergetic efficiency and entropy production of cycles were calculated. • Single-stage cycle usually has the advantages of simple structure and high COP. • Multi-stage cycles adapt to critical conditions better than single-stage cycle. • Boundary conditions for choosing optimal cycle were summarized as tables. - Abstract: Activated carbon–ammonia multi-stage adsorption refrigeration cycle was analyzed in this article, which realized deep-freezing for evaporating temperature under −18 °C with heating source temperature much lower than 100 °C. Cycle mathematical models for single, two and three-stage cycles were established on the basis of thorough thermodynamic analysis. According to simulation results of thermodynamic evaluation indicators such as COP (coefficient of performance), exergetic efficiency and cycle entropy production, multi-stage cycle adapts to high condensing temperature, low evaporating temperature and low heating source temperature well. Proposed cycle with selected working pair can theoretically work under very severe conditions, such as −25 °C evaporating temperature, 40 °C condensing temperature, and 70 °C heating source temperature, but under these working conditions it has the drawback of low cycle adsorption quantity. It was found that both COP and exergetic efficiency are of great reference value in the choice of cycle, whereas entropy production is not so useful for cycle stage selection. Finally, the application boundary conditions of single-stage, two-stage, and three-stage cycles were summarized as tables according to the simulation results, which provides reference for choosing optimal cycle under different conditions.

  20. Induction Acceleration of a Single RF Bunch in the KEK PS

    CERN Document Server

    Takayama, Ken; Arakida, Yoshio; Horioka, Kazuhiko; Igarashi, Susumu; Iwashita, Taiki; Kawasaki, Atsushi; Kishiro, Junichi; Kono, Tadaaki; Koseki, Kunio; Nakamura, Eiji; Sakuda, Makoto; Sato, Hikaru; Shiho, Makoto; Shimosaki, Yoshito; Shirakata, Masashi; Sueno, Tsuyoshi; Tokuchi, Akira; Torikai, Kota; Toyama, Takeshi; Wake, Masayoshi; Watanabe, Masao; Yamane, Isao

    2005-01-01

    A single bunch trapped in an RF bucket was accelerated by induction devices from 500 MeV to 8GeV beyond transition energy in the KEK-PS. This is the first demonstration of induction acceleration in a high energy circular ring. The acceleration was confirmed by measuring a temporal evolution of the RF phase through an entire acceleration.* Key devices in an induction acceleration system are an induction accelerating cavity capable of generating an induced voltage of 2kV/cell, a pulse modulator to drive the cavity (switching driver), and a DSP system to control gate signals for switching. Their remarkable characteristics are its repetition ratio of about 1MHz and duty factor of 50%. All devices have been newly developed at KEK so as to meet this requirement. The pulse modulator employing MOSFETs as switching elements is connected with the accelerating cavity through a long transmission cable in order to avoid a high-dose irradiation in the accelerator tunnel. The induction system has been running beyond more th...

  1. Integrated single- and two-photon light sheet microscopy using accelerating beams

    DEFF Research Database (Denmark)

    Piksarv, Peeter; Marti, Dominik; Le, Tuan

    2017-01-01

    We demonstrate the first light sheet microscope using propagation invariant, accelerating Airy beams that operates both in single- and two-photon modes. The use of the Airy beam permits us to develop an ultra compact, high resolution light sheet system without beam scanning. In two-photon mode, a...

  2. Accelerators

    CERN Multimedia

    CERN. Geneva

    2001-01-01

    The talk summarizes the principles of particle acceleration and addresses problems related to storage rings like LEP and LHC. Special emphasis will be given to orbit stability, long term stability of the particle motion, collective effects and synchrotron radiation.

  3. Predictive coding accelerates word recognition and learning in the early stages of language development.

    Science.gov (United States)

    Ylinen, Sari; Bosseler, Alexis; Junttila, Katja; Huotilainen, Minna

    2017-11-01

    The ability to predict future events in the environment and learn from them is a fundamental component of adaptive behavior across species. Here we propose that inferring predictions facilitates speech processing and word learning in the early stages of language development. Twelve- and 24-month olds' electrophysiological brain responses to heard syllables are faster and more robust when the preceding word context predicts the ending of a familiar word. For unfamiliar, novel word forms, however, word-expectancy violation generates a prediction error response, the strength of which significantly correlates with children's vocabulary scores at 12 months. These results suggest that predictive coding may accelerate word recognition and support early learning of novel words, including not only the learning of heard word forms but also their mapping to meanings. Prediction error may mediate learning via attention, since infants' attention allocation to the entire learning situation in natural environments could account for the link between prediction error and the understanding of word meanings. On the whole, the present results on predictive coding support the view that principles of brain function reported across domains in humans and non-human animals apply to language and its development in the infant brain. A video abstract of this article can be viewed at: http://hy.fi/unitube/video/e1cbb495-41d8-462e-8660-0864a1abd02c. [Correction added on 27 January 2017, after first online publication: The video abstract link was added.]. © 2016 John Wiley & Sons Ltd.

  4. Design stage confirmation of lifetime improvement for newly modified products through accelerated life testing

    Energy Technology Data Exchange (ETDEWEB)

    Mohammadian, S. Hossein, E-mail: seyed-h.mohammadian.1@ulaval.c [Centre Interuniversitaire de Recherche sur les Reseaux d' Entreprise, la Logistique et le Transport (CIRRELT), Departement de Genie Mecanique, Pavillon Adrien-Pouliot, Universite Laval, Quebec, G1V 0A6 (Canada) and Centre Interdisciplinaire de Recherche en Readaptation et en Integration Sociale (CIRRIS), Institut de Readaptation en Deficience Physique de Quebec, 525 Boul. Hamel, Quebec, G1M 2S8 (Canada); Ait-Kadi, Daoud, E-mail: Daoud.Aitkadi@gmc.ulaval.c [Centre Interuniversitaire de Recherche sur les Reseaux d' Entreprise, la Logistique et le Transport (CIRRELT), Departement de Genie Mecanique, Pavillon Adrien-Pouliot, Universite Laval, Quebec, G1V 0A6 (Canada); Centre Interdisciplinaire de Recherche en Readaptation et en Integration Sociale (CIRRIS), Institut de Readaptation en Deficience Physique de Quebec, 525 Boul. Hamel, Quebec, G1M 2S8 (Canada)

    2010-08-15

    After a modification to the original version of a product and before mass production, the expected improvement in the product lifetime or reliability needs to be validated. This paper presents three approaches based on accelerated life testing to verify, estimate and confirm the lifetime or reliability of a newly modified product at design stage: ALT comparative approach, reliability estimation approach, and reliability validation test. Test samples of the original and modified versions are expected to fail during the tests in order to obtain their failure time data. In ALT comparative approach, the statistical comparison between failure time data of the original and modified versions is used to verify the required improvement in lifetime. In reliability estimation approach, the relationship made between available lifetime and failure time data of the original version is used to extrapolate lifetime data of the modified version from its failure time data. Since modified versions are usually highly reliable, all test samples might survive the tests (without any failures) that results in the lack of failure time data for statistical analysis. To confirm a level of service reliability with confidence, reliability validation test is presented to make an estimate of the number of samples required to survive the tests. To fulfill the same level of confidence for fewer number of prototypes (as test samples), the test time must be extended. On the other hand, more prototypes are needed to pass a shorter test time if there are any time constraints.

  5. Design stage confirmation of lifetime improvement for newly modified products through accelerated life testing

    International Nuclear Information System (INIS)

    Mohammadian, S. Hossein; Ait-Kadi, Daoud

    2010-01-01

    After a modification to the original version of a product and before mass production, the expected improvement in the product lifetime or reliability needs to be validated. This paper presents three approaches based on accelerated life testing to verify, estimate and confirm the lifetime or reliability of a newly modified product at design stage: ALT comparative approach, reliability estimation approach, and reliability validation test. Test samples of the original and modified versions are expected to fail during the tests in order to obtain their failure time data. In ALT comparative approach, the statistical comparison between failure time data of the original and modified versions is used to verify the required improvement in lifetime. In reliability estimation approach, the relationship made between available lifetime and failure time data of the original version is used to extrapolate lifetime data of the modified version from its failure time data. Since modified versions are usually highly reliable, all test samples might survive the tests (without any failures) that results in the lack of failure time data for statistical analysis. To confirm a level of service reliability with confidence, reliability validation test is presented to make an estimate of the number of samples required to survive the tests. To fulfill the same level of confidence for fewer number of prototypes (as test samples), the test time must be extended. On the other hand, more prototypes are needed to pass a shorter test time if there are any time constraints.

  6. Evaluation of an automated single-channel sleep staging algorithm

    OpenAIRE

    Kaplan, Richard; Wang,Ying; Loparo,Kenneth; Kelly,Monica

    2015-01-01

    Ying Wang,1 Kenneth A Loparo,1,2 Monica R Kelly,3 Richard F Kaplan1 1General Sleep Corporation, Euclid, OH, 2Department of Electrical Engineering and Computer Science, Case Western Reserve University, Cleveland, OH, 3Department of Psychology, University of Arizona, Tucson, AZ, USA Background: We previously published the performance evaluation of an automated electroencephalography (EEG)-based single-channel sleep–wake detection algorithm called Z-ALG used by the Zmachine® s...

  7. Active vibration control of a single-stage spur gearbox

    Science.gov (United States)

    Dogruer, C. U.; Pirsoltan, Abbas K.

    2017-02-01

    The dynamic transmission error between driving and driven gears of a gear mechanism with torsional mode is induced by periodic time-varying mesh stiffness. In this study, to minimize the adverse effect of this time-varying mesh stiffness, a nonlinear controller which adjusts the torque acting on the driving gear is proposed. The basic approach is to modulate the input torque such that it compensates the periodic change in mesh stiffness. It is assumed that gears are assembled with high precision and gearbox is analyzed by a finite element software to calculate the mesh stiffness curve. Thus, change in the mesh stiffness, which is inherently nonlinear, can be predicted and canceled by a feed-forward loop. Then, remaining linear dynamics is controlled by pole placement techniques. Under these premises, it is claimed that any acceleration and velocity profile of the input shaft can be tracked accurately. Thereby, dynamic transmission error is kept to a minimum possible value and a spur gearbox, which does not emit much noise and vibration, is designed.

  8. Single-stage revision for periprosthetic hip infection using antibiotic loaded impaction graft.

    Science.gov (United States)

    Ebied, Ayman M; Elseedy, Adel I; Gamal, Osama

    2016-11-10

    Staged revision for periprosthetic infection of the hip is an accepted and widely used technique by many surgeons. However, single-stage exchange of the hip prosthesis remains an attractive option to others because of the advantages of reduced morbidity, shorter treatment time and hospital stay in addition to the reduced cost of treatment. Single-stage revision for periprosthetic hip infection can achieve excellent results if a specific protocol for patients' selection and management is followed. 52 patients with evidence of periprosthetic infection had preoperative aspiration of the affected hip. The infecting organisms were identified in 33/52 and single-stage revision was performed. The remaining 19 patients had a 2-stage exchange arthroplasty. Patients in the single-stage revision protocol had antibiotic loaded morsellized bone graft, a cemented cup and a long cementless stem. At an average follow up of 6 (range 4-8) years postoperatively, only 1 case of persistent infection was found in the single-stage group - a 97% rate of eradicating infection was achieved. Single-stage exchange achieves excellent success rate in patients with periprosthetic infection when a specific protocol for patient selection and management is followed.

  9. Optimization And Single-Shot Characterization Of Ultrashort Thz Pulses From A Laser Wakefield Accelerator

    International Nuclear Information System (INIS)

    Plateau, G.R.; Matlis, N.H.; van Tilborg, J.; Geddes, C.G.R.; Toth, Cs.; Schroeder, C.B.; Leemans, W.P.

    2009-01-01

    We present spatiotemporal characterization of μJ-class ultrashort THz pulses generated from a laser wakefield accelerator (LWFA). Accelerated electrons, resulting from the interaction of a high-intensity laser pulse with a plasma, emit high-intensity THz pulses as coherent transition radiation. Such high peak-power THz pulses, suitable for high-field (MV/cm) pump-probe experiments, also provide a non-invasive bunch-length diagnostic and thus feedback for the accelerator. The characterization of the THz pulses includes energy measurement using a Golay cell, 2D sign-resolved electro-optic measurement and single-shot spatiotemporal electric-field distribution retrieval using a new technique, coined temporal electric-field cross-Correlation (TEX). All three techniques corroborate THz pulses of ∼ 5 μJ, with peak fields of 100's of kV/cm and ∼ 0.4 ps rms duration.

  10. Radiation Fields in High Energy Accelerators and their impact on Single Event Effects

    CERN Document Server

    García Alía, Rubén; Wrobel, Frédéric; Brugger, Markus

    Including calculation models and measurements for a variety of electronic components and their concerned radiation environments, this thesis describes the complex radiation field present in the surrounding of a high-energy hadron accelerator and assesses the risks related to it in terms of Single Event Effects (SEE). It is shown that this poses not only a serious threat to the respective operation of modern accelerators but also highlights the impact on other high-energy radiation environments such as those for ground and avionics applications. Different LHC-like radiation environments are described in terms of their hadron composition and energy spectra. They are compared with other environments relevant for electronic component operation such as the ground-level, avionics or proton belt. The main characteristic of the high-energy accelerator radiation field is its mixed nature, both in terms of hadron types and energy interval. The threat to electronics ranges from neutrons of thermal energies to GeV hadron...

  11. Initial Results of Accelerated Stress Testing on Single-Channel and Multichannel Drivers: Solid-State Lighting Technology Area

    Energy Technology Data Exchange (ETDEWEB)

    None

    2018-02-28

    This report is the first in a series of studies on accelerated stress testing (AST) of drivers used for SSL luminaires, such as downlights, troffers, and streetlights. A representative group of two-stage commercial driver products was exposed to an AST environment consisting of 75°C and 75% relative humidity (7575). These drivers were a mix of single-channel drivers (i.e., a single output current for one LED primary) and multichannel drivers (i.e., separate output currents for multiple LED primaries). This AST environment was chosen because previous testing on downlights with integrated drivers demonstrated that 38% of the sample population failed in less than 2,500 hours of testing using this method. In addition to AST test results, the performance of an SSL downlight product incorporating an integrated, multichannel driver during extended room temperature operational life (RTOL) testing is also reported. A battery of measurements was used to evaluate these products during accelerated testing, including full electrical characterization (i.e., power consumption, PF, total harmonic distortion [THD], and inrush current) and photometric characterization of external LED loads attached to the drivers (i.e., flicker performance and lumen maintenance).

  12. Single-bunch beam loading on the SLAC two-mile accelerator

    International Nuclear Information System (INIS)

    Koontz, R.F.

    1976-05-01

    The experiments described were initially prompted by interest in the radiation loss of relativistic electron rings passing through periodic structures. Later the same experiments became relevant to the theory of energy loss of electrons in large storage rings. In both of these cases energy loss to the higher order modes of the respective structures could seriously limit their effective operation. In these experiments, single bunches of electrons with intensities up to 7 x 10 8 electrons per bunch are accelerated through the SLAC three-kilometer accelerator, and their energy spectra are analyzed. Early experiments over a wide energy range (900 MeV to 19 GeV) demonstrated that the energy loss was proportional to the total charge in the bunch but was independent of beam energy. The average energy loss of a single bunch normalized to 10 9 electrons was initially measured to be 38 MeV

  13. Single-Stage Revision Arthroplasty for Infection-An Underutilized Treatment Strategy.

    Science.gov (United States)

    Negus, Jonathan J; Gifford, Peter B; Haddad, Fares S

    2017-07-01

    The burden of revision arthroplasty surgery for infection is rising as the rate of primary arthroplasty surgery increases. Infected arthroplasty rates are now relatively low, but the sheer increase in volume is leading to considerable patient morbidity and significant increases in costs to the health care system. Single-stage revision for infection is one of the several accepted treatment options, but the indications and results are debated. This review aims to clarify the current evidence. MEDLINE/PubMed databases were reviewed for studies that looked at single- or one-stage revision knee or hip arthroplasty for infection. There is increasing evidence that single-stage revision for infection can control infection and with decreased morbidity, mortality, and health care costs compared with a staged approach. However, the indications are still debated. Recently, there has been a determined effort to define an infected arthroplasty in a manner that will allow for standardization of reporting in the literature. The evidence supporting single stage for knee arthroplasty is catching up with the result with hip arthroplasty. High-quality data from randomized controlled trials are now pending. After the gradual evolution of using the single-stage approach, with the widespread acceptance of this definition, we can now standardize comparisons across the world and move toward a refined definition of the ideal patient population for single-stage arthroplasty revision in both the hip and the knee population. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Single Stage Knee Arthroplasty Revision Surgery: A Systematic Review of the Literature.

    Science.gov (United States)

    Chew, E; Khan, W S; Agarwal, S; Morgan-Jones, R

    2015-01-01

    Total Knee Arthroplasty is an increasingly common procedure and revision surgery, particularly for infection, is associated with significant morbidity and healthcare costs. The current gold standard is a two stage revision procedure but single stage revision is increasingly being used in some departments to improve patient outcomes. We conducted a systematic review of the literature to determine the up-to-date evidence underlying the use of a single stage knee approach in revision surgery. A total of 12 studies were included in this review amounting to 433 revision surgeries. This is the largest review of single stage knee revision surgery. The procedures described were heterogenous and included the 'two-in-one' technique as well as other single stage revision procedures. There were also differences in implants and antibiotic regimens. The mean re-infection rates described in 10 studies was 9.4% (range 0-19.2%) after a mean follow-up of 40.3 months (range 7-180 months). The re-infection rates in the studies published over the last 30 years are falling, and this is not accounted for by any significant change in duration of follow-up during this period. The outcome scores varied, but patients generally showed an improvement. The Knee Society Score and the Oxford Knee Score were the most commonly used in five and three studies respectively. We conclude that the current evidence for single stage revision is variable and there is a lack of good quality evidence to address whether single stage revisions is thorough enough to eradicate deep infection and is able to restore adequate function. There is a need for larger prospective studies with standardised procedures and protocol, and with adequate follow-up. Till then, patients considered for a single stage approach should be thoroughly assessed and the surgery should be performed by a senior surgeon with experience in single stage knee revisions.

  15. Characterestics of pico-second single bunch at the S-band linear accelerator

    International Nuclear Information System (INIS)

    Uesaka, Mitsuru; Kozawa, Takahiro; Kobayashi, Toshiaki; Ueda, Toru; Miya, Kenzo

    1994-01-01

    Measurement of the bunch structure of a pico-second single bunch was performed using a femto-second streak camera at the S-band linear accelerator of the University of Tokyo. The aim of this research is to investigate the feasibility of the generation of a femto-second single bunch at the S-band linac. The details of the bunch structure and energy spectrum of an original single bunch were precisely investigated in several operation modes where the RF phases in accelerating tubes and a prebuncher were varied. The femto-second streak camera was utilized to measure the bunch structure by one shot via Cherenkov radiation emitted by the electrons in the bunch. Next, an experiment for magnetic pulse compression of the original single bunch was carried out. Pulse shapes of the compressed bunchs for different energy modulation were also obtained by measuring Cherenkov radiation by one shot using the femto-second streak camera. Prior to the experiment, numerical tracking analysis to determine operating parameters for the magnetic pulse compression was also done. Measured pulse widths were compared with calculated ones. Finally, a 2 ps (full width at half maximum; FWHM) single bunch with an electric charge of 0.3 nC could be generated by the magnetic pulse compression. ((orig.))

  16. Use of skin stretchers for single-stage bilateral mastectomies in a dog and a cat.

    Science.gov (United States)

    Miyazaki, Yuta; Aikawa, Takeshi; Shimatsu, Taichi; Nishimura, Masaaki; Sadahiro, Shigeo

    2018-04-01

    To describe the application of skin stretchers for closure of single-stage bilateral mastectomies in a dog and a cat. Clinical case report. A 12-year-old intact female Miniature Dachshund and a 13-year-old spayed female domestic short-hair cat. Skin stretchers were applied to the site of the skin adjacent to mammary glands for 2-4 days before surgery. Cable tension was adjusted every 6-8 hours to elongate the skin and to achieve primary closure of single-stage bilateral mastectomy without tension. Wound closure after single-stage bilateral mastectomy was achieved without tension or major complication in both animals. Use of skin stretchers allows primary closure of single-stage bilateral mastectomy in dogs and cats. © 2017 The American College of Veterinary Surgeons.

  17. Single-Stage, Gelled Hydrazine System for Mars Ascent Vehicle Propulsion, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Microcosm, Inc. in cooperation with Aerojet Rocketdyne is presenting an innovative approach to the Mars Ascent Vehicle (MAV). The single-stage monopropellant system...

  18. Single Stage Transthoracic Approach to the Right Lung and Liver Dome Hydatid Cysts

    Directory of Open Access Journals (Sweden)

    Rasih Yazkan

    2011-09-01

    lung, the hepatic lesions were all of the dome located. Conclusions :Single stage transthoracic approach is prevent the second surgical procedures on simultaneous right lung and liver dome hydatid cyst and it is safe and effective method.

  19. NOFBX Single-Stage-to-Orbit Mars Ascent Vehicle Engine, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose the continuation of our research and development of a Nitrous Oxide Fuel Blend (NOFBXTM) Single-Stage-to-Orbit (SSTO) monopropellant propulsion system for...

  20. Elimination of pharmaceuticals in single- and three-stage pre-denitrifying MBBR

    DEFF Research Database (Denmark)

    Polesel, Fabio; Torresi, Elena; Loreggian, L.

    This study investigated the elimination of pharmaceuticals in pre-denitrifying moving bed biofilm reactors (MBBRs) in single- and three-stage configurations. Under batch conditions, biotransformation and retransformation of two pharmaceuticals (trimethoprim, sulfamethoxazole) occurred at comparab...

  1. Is Single-stage Revision Safe Following Infected Total Knee Arthroplasty? A Critical Review.

    Science.gov (United States)

    Vaishya, Raju; Agarwal, Amit Kumar; Rawat, Sudheer K; Singh, Harsh; Vijay, Vipul

    2017-08-30

    With the improvement in outcomes and modern prosthesis design, total knee arthroplasty (TKA) has now become a commonly performed surgery. It is postulated that a total of 2-5% of the primary and revision TKA becomes infected every year, requiring a revision procedure which to date is the conventional two-stage revision. The diagnosis and treatment of these periprosthetic infections is a major and challenging task, as it requires precise identification of the pathogen, meticulous debridement, and postoperative rehabilitation. To date, there have been very few studies in existing literature comparing the outcomes of single-stage versus two-stage procedure in infected TKA. The aim of the review was to provide the clinicians an insight into the outcome of the single-stage procedure compared to two-stage procedures and to suggest ways to improve the results further. In the following critical review, a total of 669 cases that underwent either a single or two-stage revision for infected TKA were studied. The postoperative functional scores were comparable in most studies during the early postoperative period. Our data supports the use of a single-stage revision surgery in infected TKA as an alternative to a conventional two-stage procedure. However, larger prospective and multicentric trials are required to validate our findings.

  2. Resent advance in electron linear accelerators

    International Nuclear Information System (INIS)

    Takeda, Seishi; Tsumori, Kunihiko; Takamuku, Setsuo; Okada, Toichi; Hayashi, Koichiro; Kawanishi, Masaharu

    1986-01-01

    In recently constructed electron linear accelerators, there has been remarkable advance both in acceleration of a high-current single bunch electron beam for radiation research and in generation of high accelerating gradient for high energy accelerators. The ISIR single bunch electron linear accelerator has been modified an injector to increase a high-current single bunch charge up to 67 nC, which is ten times greater than the single bunch charge expected in early stage of construction. The linear collider projects require a high accelerating gradient of the order of 100 MeV/m in the linear accelerators. High-current and high-gradient linear accelerators make it possible to obtain high-energy electron beam with small-scale linear accelerators. The advance in linear accelerators stimulates the applications of linear accelerators not only to fundamental research of science but also to industrial uses. (author)

  3. On the preservation of single- and multi-bunch emittance in linear accelerators

    International Nuclear Information System (INIS)

    Drevlak, M.

    1995-11-01

    This document is concentrated on the investigation of the dynamics of a particle beam in a linear accelerator. We numerically simulate a number of effects and evaluate the severity of their impact on the beam. Furthermore, we examine the applicability of several correction techniques aiming at the suppression or correction of the effects diluting the beam emittance. First, there is the issue of single-bunch dynamics : we see that wake field effects and dispersive errors can cause a significant emittance growth. Secondly, long range dipole wakes and dispersive effects arising from the energy spread between different bunches will cause relative offsets between the individual bunches and likewise result in emittance growth. Finally, we observe interactions between the single-bunch and multi-bunch dynamics in a bunch train, which further aggravate these effects. The corrective measures against emittance growth are first tested with respect to individual effects relating to issues of single- or multi-bunch dynamics. Later, these different correction techniques are joined to one machine tuning procedure that will be applied in order to achieve good emittance preservation for operation of the accelerator with a full beam consisting of the full number of bunches. The performance of this procedure is tested in simulations of the combined single- and multi-bunch dynamics. Finally, tolerances on the machine alignment as well as machine and beam parameters are established. (orig.)

  4. Acceleration of small, light projectiles (including hydrogen isotopes) to high speeds using a two-stage light gas gun

    International Nuclear Information System (INIS)

    Combs, S.K.; Foust, C.R.; Gouge, M.J.; Milora, S.L.

    1989-01-01

    Small, light projectiles have been accelerated to high speeds using a two-stage light gas gun at Oak Ridge National Laboratory. With 35-mg plastic projectiles (4 mm in diameter), speeds of up to 4.5 km/s have been recorded. The ''pipe gun'' technique for freezing hydrogen isotopes in situ in the gun barrel has been used to accelerate deuterium pellets (nominal diameter of 4 mm) to velocities of up to 2.85 km/s. The primary application of this technology is for plasma fueling of fusion devices via pellet injection of hydrogen isotopes. Conventional pellet injectors are limited to pellet speeds in the range 1-2 km/s. Higher velocities are desirable for plasma fueling applications, and the two-stage pneumatic technique offers performance in a higher velocity regime. However, experimental results indicate that the use of sabots to encase the cryogenic pellets and protect them for the high peak pressures will be required to reliably attain intact pellets at speeds of ∼3 km/s or greater. In some limited tests, lithium hydride pellets were accelerated to speeds of up to 4.2 km/s. Also, repetitive operation of the two-stage gun (four plastic pellets fired at ∼0.5 Hz) was demonstrated for the first time in preliminary tests. The equipment and operation are described, and experimental results and some comparisons with a theoretical model are presented. 17 refs., 6 figs., 2 tabs

  5. Single-drop liquid phase microextraction accelerated by surface acoustic wave.

    Science.gov (United States)

    Zhang, Anliang; Zha, Yan

    2013-03-01

    A single-drop liquid phase microextraction method is presented, in which surface acoustic wave (SAW) is used for accelerating extraction speed. A pair of interdigital transducers with 27.5 MHz center frequency is fabricated on a 128° yx-LiNbO3 substrate. A radio frequency signal is applied to one of interdigital transducers to excite SAW. Plastic straw is filled with PDMS, leaving 1 mL for holding sample solution. Plastic straw with sample solution droplet is then dipping into extractant, into which SAW is radiated. Mass transportation from sample solution to extractant drop is accelerated due to acoustic streaming, and extraction time is decreased. An ionic liquid and an acid green-25 solution are used for extraction experiments. Results show that the extraction process is almost finished within 2 min, and extraction speed is increased with radio frequency signal power. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Two-stage IMZ implants and ITI implants inserted in a single-stage procedure. A prospective comparative study.

    Science.gov (United States)

    Heydenrijk, Kees; Raghoebar, Gerry M; Meijer, Henny J A; van der Reijden, Willy A; van Winkelhoff, Arie Jan; Stegenga, Boudewijn

    2002-08-01

    The aim of this study was to evaluate the feasibility of using a two-stage implant system in a single-stage procedure and to study the impact of the microgap at crestal level and to monitor the microflora in the peri-implant area. Forty edentulous patients (Cawood & Howell class V-VI) participated in this study. After randomisation, 20 patients received two IMZ implants inserted in a single-stage procedure and 20 patients received two ITI implants. After 3 months, overdentures were fabricated, supported by a bar and clip attachment. A standardised clinical and radiographic evaluation was performed immediately after denture insertion and 6 and 12 months later. Twelve months after loading, peri-implant samples were collected with sterile paper points and analysed for the presence of putative periodontal pathogens using culture techniques. One IMZ implant was lost due to insufficient osseointegration. With regard to the clinical parameters at the 12 months evaluation, significant differences for plaque score and probing pocket depth (IMZ: mean 3.3 mm, ITI: mean 2.9 mm) were found between the two groups. The mean bone loss in the first year of functioning was 0.6 mm for both groups. Prevotella intermedia was detected more often in the ITI group (12 implants) than in the IMZ group (three implants). Porphyromonas gingivalis was found in three patients. In one of these patients an implant showed bone loss of 1.6 mm between T0 and T12. Some associations were found between clinical parameters and the target microorganisms in the ITI group. These associations were not present in the IMZ group. The short-term results indicate that two-stage implants inserted in a single-stage procedure may be as predictable as one-stage implants. The microgap at crestal level in nonsubmerged IMZ implants seems to have no adverse influence on the peri-implant microbiological colonisation and of crestal bone loss in the first year of functioning. The peri-implant sulcus can and does harbour

  7. Development of a Charged Particle Microbeam for Single-Particle Subcellular Irradiations at the MIT Laboratory for Accelerator Beam Application

    International Nuclear Information System (INIS)

    Yanch, Jacquelyn C.

    2004-01-01

    The development of a charged particle microbeam for single particle, subcellular irradiations at the Massachusetts Institute of Technology Laboratory for Accelerator Beam Applications (MIT LABA) was initiated under this NEER aeard. The Microbeam apparatus makes use of a pre-existing electrostatic accelerator with a horizontal beam tube

  8. Effect of obstacle size and spacing on the initial stage of flame acceleration in a rough tube

    Science.gov (United States)

    Ciccarelli, G.; Fowler, C. J.; Bardon, M.

    2005-11-01

    Experiments were conducted to study flame acceleration in an orifice plate laden detonation tube. Orifice plate area blockage and spacing were varied to determine their affect on flame acceleration. The tube used in the study was 3.05 m long with an inner diameter of 14.0 cm. Experiments were primarily carried out with stoichiometric propane-air, however the affect of mixture reactivity was also investigated by varying the mixture equivalence ratio. The distance required for the flame to achieve a velocity equal to the speed of sound in the unburned gas mixture was measured. This run-up distance is used to characterize the early stage of the flame acceleration process. It was found that in all cases, the flame run-up distance decreased with increased blockage ratio and with increased mixture reactivity. It was found that for higher blockage ratios plates flame acceleration was greatest for a plate spacing of one tube diameter, but for lower blockage ratio plates the results obtained for one-half, one, and one and one-half tube diameter plate spacing were very similar. The most rapid flame acceleration was observed when the ratio of the orifice plate spacing and the orifice plate height (half of the difference between the tube and orifice plate diameter) is on the order of 5. It is proposed that this optimum acceleration corresponds to the condition where the plate spacing is roughly equal to the length of the unburned gas re-circulation zone downstream from the orifice plate.

  9. Concept of a staged FEL enabled by fast synchrotron radiation cooling of laser-plasma accelerated beam by solenoidal magnetic fields in plasma bubble

    Science.gov (United States)

    Seryi, Andrei; Lesz, Zsolt; Andreev, Alexander; Konoplev, Ivan

    2017-03-01

    A novel method for generating GigaGauss solenoidal fields in a laser-plasma bubble, using screw-shaped laser pulses, has been recently presented. Such magnetic fields enable fast synchrotron radiation cooling of the beam emittance of laser-plasma accelerated leptons. This recent finding opens a novel approach for design of laser-plasma FELs or colliders, where the acceleration stages are interleaved with laser-plasma emittance cooling stages. In this concept paper, we present an outline of what a staged plasma-acceleration FEL could look like, and discuss further studies needed to investigate the feasibility of the concept in detail.

  10. Miniature, Single Channel, Memory-Based, High-G Acceleration Recorder (Millipen)

    International Nuclear Information System (INIS)

    Rohwer, Tedd A.

    1999-01-01

    The Instrumentation and Telemetry Departments at Sandia National Laboratories have been instrumenting earth penetrators for over thirty years. Recorded acceleration data is used to quantify penetrator performance. Penetrator testing has become more difficult as desired impact velocities have increased. This results in the need for small-scale test vehicles and miniature instrumentation. A miniature recorder will allow penetrator diameters to significantly decrease, opening the window of testable parameters. Full-scale test vehicles will also benefit from miniature recorders by using a less intrusive system to instrument internal arming, fusing, and firing components. This single channel concept is the latest design in an ongoing effort to miniaturize the size and reduce the power requirement of acceleration instrumentation. A micro-controller/memory based system provides the data acquisition, signal conditioning, power regulation, and data storage. This architecture allows the recorder, including both sensor and electronics, to occupy a volume of less than 1.5 cubic inches, draw less than 200mW of power, and record 15kHz data up to 40,000 gs. This paper will describe the development and operation of this miniature acceleration recorder

  11. Computer simulations of a single-laser double-gas-jet wakefield accelerator concept

    Directory of Open Access Journals (Sweden)

    R. G. Hemker

    2002-04-01

    Full Text Available We report in this paper on full scale 2D particle-in-cell simulations investigating laser wakefield acceleration. First we describe our findings of electron beam generation by a laser propagating through a single gas jet. Using realistic parameters which are relevant for the experimental setup in our laboratory we find that the electron beam resulting after the propagation of a 0.8 μm, 50 fs laser through a 1.5 mm gas jet has properties that would make it useful for further acceleration. Our simulations show that the electron beam is generated when the laser exits the gas jet, and the properties of the generated beam, especially its energy, depend only weakly on most properties of the gas jet. We therefore propose to use the first gas jet as a plasma cathode and then use a second gas jet placed immediately behind the first to provide additional acceleration. Our simulations of this proposed setup indicate the feasibility of this idea and also suggest ways to optimize the quality of the resulting beam.

  12. A fast-acting hydrogen gas source for staged pneumatic high-speed acceleration of fusion plasma fuel pellets

    International Nuclear Information System (INIS)

    Andersen, S.A.; Baekmark, L.

    1990-02-01

    This report describes a possible design of a fast, high-temperature, arc-driven hydrogen gas source module, to be used in a scheme for multistage high-speed pneumatic acceleration of fusion plasma fuel pellets. The potential of this scheme for operating with a moderate driving pressure at long acceleration path lengths is particular attractive for accelerating fragile hydrogen isotope ice pellets. From experiments with an ethanol-based arc unit, design parameters for a propeller module were assessed, and with a barrel-mounted ethanol module staged pneumatic acceleration of a plastic dummy pellet was demonstrated. In experiments with a hydrogenbased, cryogenic arc unit in which 200 joules of electrical energy were dissipated with a power level approaching 5 MW within 30 mus, the velocity of a 23-mg plastic pellet was increased from 1.7 to 2.4 km/s. Results in terms of barrel pressure transients and arc characteristics are described. (author) 20 ills., 8 refs

  13. Numerical Simulation of single-stage axial fan operation under dusty flow conditions

    Science.gov (United States)

    Minkov, L. L.; Pikushchak, E. V.

    2017-11-01

    Assessment of the aerodynamic efficiency of the single-stage axial flow fan under dusty flow conditions based on a numerical simulation using the computational package Ansys-Fluent is proposed. The influence of dust volume fraction on the dependences of the air volume flow rate and the pressure drop on the rotational speed of rotor is demonstrated. Matching functions for formulas describing a pressure drop and volume flow rate in dependence on the rotor speed and dust content are obtained by numerical simulation for the single-stage axial fan. It is shown that the aerodynamic efficiency of the single-stage axial flow fan decreases exponentially with increasing volume content of dust in the air.

  14. Accelerated rogue waves generated by soliton fusion at the advanced stage of supercontinuum formation in photonic-crystal fibers.

    Science.gov (United States)

    Driben, Rodislav; Babushkin, Ihar

    2012-12-15

    Soliton fusion is a fascinating and delicate phenomenon that manifests itself in optical fibers in case of interaction between copropagating solitons with small temporal and wavelength separation. We show that the mechanism of acceleration of a trailing soliton by dispersive waves radiated from the preceding one provides necessary conditions for soliton fusion at the advanced stage of supercontinuum generation in photonic-crystal fibers. As a result of fusion, large-intensity robust light structures arise and propagate over significant distances. In the presence of small random noise the delicate condition for the effective fusion between solitons can easily be broken, making the fusion-induced giant waves a rare statistical event. Thus oblong-shaped giant accelerated waves become excellent candidates for optical rogue waves.

  15. Outcomes of single-stage grip-release reconstruction in tetraplegia.

    Science.gov (United States)

    Reinholdt, Carina; Fridén, Jan

    2013-06-01

    To evaluate the outcomes of our technique for single-stage grip-release reconstruction and compare it with previous 1- and 2-stage grip reconstructions in tetraplegia. A total of 14 patients (16 hands) with tetraplegia underwent a single-stage combination of operations to provide pinch, grip, and release function. We compared the study group with a historical control group of 15 patients (18 hands) who had been treated with staged flexion-extension grip-release reconstructions. Both groups were classified as ocular cutaneous 4. Assessment parameters included grip and pinch strength, maximal opening of the first webspace, and Canadian Occupational Performance Measurement. Both groups were rehabilitated with early active mobilization beginning the first day after surgery. Grip strength and opening of the first webspace were significantly greater in the single-stage group than in the comparative group. Pinch strength was not significantly different between groups. On the Canadian Occupational Performance Measurement score, patients belonging to the single-stage group were highly satisfied (increase of 3.7 points) and could perform several of their self-selected goals (3.5 points of improvement). The single-stage grip-release reconstruction provides people who have spinal cord injuries and tetraplegia with improved and reliable grip function; active finger flexion, active thumb flexion, passive thumb extension, and passive interossei function can all be achieved through this procedure. Early active mobilization is particularly important in improving functional outcome after this combination of grip reconstruction procedures. Therapeutic III. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  16. imulation Results of Single Stage AC- AC Converter for Induction Heating

    Directory of Open Access Journals (Sweden)

    S. ARUMUGAM

    2010-12-01

    Full Text Available This paper presents simulation of single stage Induction heating system with series Load Resonance. Low frequency AC is converted in to High Frequency Ac using newly developed ZVS-PWM high frequency inverter. This High Frequency is used for Induction Heating .Single stage AC-AC converter system is modeled and simulated using Matlab Simulink. The simulation results of ZVS-PWM high frequency system are presented. The effectiveness of this UFAC-to-HFAC direct power frequency converter using IGBTs for consumer high-frequency IH appliances is evaluated and proved on the basis of simulation results.

  17. Theoretical evaluation of the efficiency of gas single-stage reciprocating compressor medium pressure units

    Science.gov (United States)

    Busarov, S. S.; Vasil'ev, V. K.; Busarov, I. S.; Titov, D. S.; Panin, Ju. N.

    2017-08-01

    Developed earlier and tested in such working fluid as air, the technology of calculating the operating processes of slow-speed long-stroke reciprocating stages let the authors to obtain successful results concerning compression of gases to medium pressures in one stage. In this connection, the question of the efficiency of the application of slow-speed long-stroke stages in various fields of technology and the national economy, where the working fluid is other gas or gas mixture, is topical. The article presents the results of the efficiency evaluation of single-stage compressor units on the basis of such stages for cases when ammonia, hydrogen, helium or propane-butane mixture is used as the working fluid.

  18. New J-STAGE system accelerates digitization and distribution of academic journals from Japan

    Science.gov (United States)

    Sato, Ryuichi; Kubota, Soichi; Aoyama, Kota; Tsuchiya, Eri; Miyagawa, Yoshiyuki

    13 years have passed since J-STAGE was launched. At present no one could deny that its user interface and functions were already out of date comparing to foreign established e-journals. So JST has developed a new system called “J-STAGE3” in order to offer better usability and give powerful dissemination of academic papers from Japan. As the result of it, they will be able to enjoy the following things: 1) integration of two databases, Journal@rchive and J-STAGE, 2) new design/interface, 3) introduction of international standard XML format, 4) advanced subscription management, 5) saving cost of publishers, and 6) improving J-STAGE online submission and review system. At the end of March 2011, we conducted a market research on current status of digitization on Japanese society journals. The report told us that digitization ratio of those was 62% in total but it was 34% in humanities/social sciences. Or it was 92% in English journals and 55% in Japanese ones. It means that we need further promotion of digitization. In this paper, we discuss functions and direction of J-STAGE3 as well as our role in promotion of digitization of Japanese society journals.

  19. A two-phase inspection model for a single component system with three-stage degradation

    International Nuclear Information System (INIS)

    Wang, Huiying; Wang, Wenbin; Peng, Rui

    2017-01-01

    This paper presents a two-phase inspection schedule and an age-based replacement policy for a single plant item contingent on a three-stage degradation process. The two phase inspection schedule can be observed in practice. The three stages are defined as the normal working stage, low-grade defective stage and critical defective stage. When an inspection detects that an item is in the low-grade defective stage, we may delay the preventive replacement action if the time to the age-based replacement is less than or equal to a threshold level. However, if it is above this threshold level, the item will be replaced immediately. If the item is found in the critical defective stage, it is replaced immediately. A hybrid bee colony algorithm is developed to find the optimal solution for the proposed model which has multiple decision variables. A numerical example is conducted to show the efficiency of this algorithm, and simulations are conducted to verify the correctness of the model. - Highlights: • A two-phase inspection model is studied. • The failure process has three stages. • The delayed replacement is considered.

  20. Analysis of U and Pu resin bead samples with a single stage mass spectrometer

    International Nuclear Information System (INIS)

    Smith, D.H.; Walker, R.L.; Bertram, L.K.; Carter, J.A.

    1979-01-01

    Resin bead sampling enables the shipment of nanogram U and Pu quantities for analysis. Application of this sampling technique to safeguards was investigated with a single-stage mass spectrometer. Standards gave results in good agreement with NBS certified values. External precisions of +-0.5% were obtained on isotopic ratios of approx. 0.01; precisions on quantitative measurements are +-1.0%

  1. Practical Considerations Concerning the Interleaved Transition Mode Single-stage Ballast

    DEFF Research Database (Denmark)

    Teodorescu, Remus; Kjær, Søren Bækhøj; Munk-Nielsen, Stig

    2002-01-01

    The aim of this paper is to present a novel single-stage interleaved ballast focusing on practical design aspects like: key current expression, overall losses, harmonic analysis of the differential-mode EMI current and preheating ballast function. A new preheating method is also presented. A PSPI...

  2. Single-Stage Low-Power Quadrature RF Receiver Front-End: The LMV Cell

    DEFF Research Database (Denmark)

    Liscidini, Antonio; Mazzanti, Andrea; Tonietto, Riccardo

    2006-01-01

    This paper presents the first quadrature RF receiver front-end where, in a single stage, low-noise amplifier (LNA), mixer and voltage-controlled oscillator (VCO) share the same bias current. The new structure exploits the intrinsic mixing functionality of a classical LC-tank oscillator providing ...

  3. Single stage buck-boost DC-AC neutral point clamped inverter

    DEFF Research Database (Denmark)

    Mo, Wei; Loh, Poh Chiang; Andrew, A.

    2012-01-01

    This paper proposes a new single stage buck-boost DC-AC neutral point clamped inverter topology which integrates the cascaded configurations of recently introduced inductor-capacitor-capacitor-transformer impedance source network (by Adamowicz) and classic NPC configuration. As a consequence...

  4. Preoperative Single Fraction Partial Breast Radiotherapy for Early-Stage Breast Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Palta, Manisha; Yoo, Sua; Adamson, Justus D.; Prosnitz, Leonard R. [Department of Radiation Oncology, Duke University Medical Center, Durham, NC (United States); Horton, Janet K., E-mail: janet.horton@duke.edu [Department of Radiation Oncology, Duke University Medical Center, Durham, NC (United States)

    2012-01-01

    Purpose: Several recent series evaluating external beam accelerated partial breast irradiation (PBI) have reported adverse cosmetic outcomes, possibly related to large volumes of normal tissue receiving near-prescription doses. We hypothesized that delivery of external beam PBI in a single fraction to the preoperative tumor volume would be feasible and result in a decreased dose to the uninvolved breast compared with institutional postoperative PBI historical controls. Methods and Materials: A total of 17 patients with unifocal Stage T1 breast cancer were identified. Contrast-enhanced subtraction magnetic resonance images were loaded into an Eclipse treatment planning system and used to define the target volumes. A 'virtual plan' was created using four photon beams in a noncoplanar beam arrangement and optimized to deliver 15 Gy to the planning target volume. Results: The median breast volume was 1,713 cm{sup 3} (range: 1,014-2,140), and the median clinical target volume was 44 cm{sup 3} (range: 26-73). In all cases, 100% of the prescription dose covered 95% of the clinical target volume. The median conformity index was 0.86 (range: 0.70-1.12). The median percentage of the ipsilateral breast volume receiving 100% and 50% of the prescribed dose was 3.8% (range: 2.2-6.9) and 13.3% (range: 7.5-20.8) compared with 18% (range: 3-42) and 53% (range: 24-65) in the institutional historical controls treated with postoperative external beam PBI (p = .002). The median maximum skin dose was 9 Gy. The median dose to 1 and 10 cm{sup 3} of skin was 6.7 and 4.9 Gy. The doses to the heart and ipsilateral lung were negligible. Conclusion: Preoperative PBI resulted in a substantial reduction in ipsilateral breast tissue dose compared with postoperative PBI. The skin dose appeared reasonable, given the small volumes. A prospective Phase I trial evaluating this technique is ongoing.

  5. Preoperative Single Fraction Partial Breast Radiotherapy for Early-Stage Breast Cancer

    International Nuclear Information System (INIS)

    Palta, Manisha; Yoo, Sua; Adamson, Justus D.; Prosnitz, Leonard R.; Horton, Janet K.

    2012-01-01

    Purpose: Several recent series evaluating external beam accelerated partial breast irradiation (PBI) have reported adverse cosmetic outcomes, possibly related to large volumes of normal tissue receiving near-prescription doses. We hypothesized that delivery of external beam PBI in a single fraction to the preoperative tumor volume would be feasible and result in a decreased dose to the uninvolved breast compared with institutional postoperative PBI historical controls. Methods and Materials: A total of 17 patients with unifocal Stage T1 breast cancer were identified. Contrast-enhanced subtraction magnetic resonance images were loaded into an Eclipse treatment planning system and used to define the target volumes. A “virtual plan” was created using four photon beams in a noncoplanar beam arrangement and optimized to deliver 15 Gy to the planning target volume. Results: The median breast volume was 1,713 cm 3 (range: 1,014–2,140), and the median clinical target volume was 44 cm 3 (range: 26–73). In all cases, 100% of the prescription dose covered 95% of the clinical target volume. The median conformity index was 0.86 (range: 0.70–1.12). The median percentage of the ipsilateral breast volume receiving 100% and 50% of the prescribed dose was 3.8% (range: 2.2–6.9) and 13.3% (range: 7.5–20.8) compared with 18% (range: 3–42) and 53% (range: 24–65) in the institutional historical controls treated with postoperative external beam PBI (p = .002). The median maximum skin dose was 9 Gy. The median dose to 1 and 10 cm 3 of skin was 6.7 and 4.9 Gy. The doses to the heart and ipsilateral lung were negligible. Conclusion: Preoperative PBI resulted in a substantial reduction in ipsilateral breast tissue dose compared with postoperative PBI. The skin dose appeared reasonable, given the small volumes. A prospective Phase I trial evaluating this technique is ongoing.

  6. Predictive Coding Accelerates Word Recognition and Learning in the Early Stages of Language Development

    Science.gov (United States)

    Ylinen, Sari; Bosseler, Alexis; Junttila, Katja; Huotilainen, Minna

    2017-01-01

    The ability to predict future events in the environment and learn from them is a fundamental component of adaptive behavior across species. Here we propose that inferring predictions facilitates speech processing and word learning in the early stages of language development. Twelve- and 24-month olds' electrophysiological brain responses to heard…

  7. Accelerated osteogenic orthodontics technique: a 1-stage surgically facilitated rapid orthodontic technique with alveolar augmentation.

    Science.gov (United States)

    Wilcko, M Thomas; Wilcko, William M; Pulver, Jeffrey J; Bissada, Nabil F; Bouquot, Jerry E

    2009-10-01

    Demineralization of a thin layer of bone over a root prominence after corticotomy surgery can optimize the response to applied orthodontic forces. This physiologic response is consistent with the regional acceleratory phenomenon process. When combined with alveolar augmentation, one is no longer strictly at the mercy of the original alveolar volume and osseous dehiscences, and fenestrations can be corrected over vital root surfaces. This is substantiated with computerized tomographic and histologic evaluations. Two case reports are presented that demonstrate the usefulness of the accelerated osteogenic orthodontics technique in de-crowding and space closing for the correction of dental malocclusions. Orthodontics is combined with full-thickness flap reflection, selective alveolar decortication, ostectomy, and bone grafting to accomplish complete orthodontic treatment. Rapid tooth movement was demonstrated in both cases and stability up to 8 years of retention. The accelerated osteogenic orthodontics technique provides for efficient and stable orthodontic tooth movement. Frequently, the teeth can be moved further in one third to one fourth the time required for traditional orthodontics alone. This is a physiologically based treatment consistent with a regional acceleratory phenomenon and maintaining an adequate blood supply is essential.

  8. Development of a two-stage light gas gun to accelerate hydrogen pellets to high speeds for plasma fueling applications

    International Nuclear Information System (INIS)

    Combs, S.K.; Milora, S.L.; Foust, C.R.; Gouge, M.J.; Fehling, D.T.; Sparks, D.O.

    1988-01-01

    The development of a two-stage light gas gun to accelerate hydrogen isotope pellets to high speeds is under way at Oak Ridge National Laboratory. High velocities (>2 km/s) are desirable for plasma fueling applications, since the faster pellets can penetrate more deeply into large, hot plasmas and deposit atoms of fuel directly in a larger fraction of the plasma volume. In the initial configuration of the two-stage device, a 2.2-l volume (/ 3 for frozen hydrogen isotopes). However, the use of sabots to encase and protect the cryogenic pellets from the high peak pressures will probably be required to realize speeds of ∼3 km/s or greater. The experimental plan includes acceleration of hydrogen isotopes as soon as the gun geometry and operating parameters are optimized; theoretical models are being used to aid in this process. The hardware is being designed to accommodate repetitive operation, which is the objective of this research and is required for future applications. 25 refs., 6 figs., 1 tab

  9. Genomic Prediction of Single Crosses in the Early Stages of a Maize Hybrid Breeding Pipeline

    Directory of Open Access Journals (Sweden)

    Dnyaneshwar C. Kadam

    2016-11-01

    Full Text Available Prediction of single-cross performance has been a major goal of plant breeders since the beginning of hybrid breeding. Recently, genomic prediction has shown to be a promising approach, but only limited studies have examined the accuracy of predicting single-cross performance. Moreover, no studies have examined the potential of predicting single crosses among random inbreds derived from a series of biparental families, which resembles the structure of germplasm comprising the initial stages of a hybrid maize breeding pipeline. The main objectives of this study were to evaluate the potential of genomic prediction for identifying superior single crosses early in the hybrid breeding pipeline and optimize its application. To accomplish these objectives, we designed and analyzed a novel population of single crosses representing the Iowa Stiff Stalk synthetic/non-Stiff Stalk heterotic pattern commonly used in the development of North American commercial maize hybrids. The performance of single crosses was predicted using parental combining ability and covariance among single crosses. Prediction accuracies were estimated using cross-validation and ranged from 0.28 to 0.77 for grain yield, 0.53 to 0.91 for plant height, and 0.49 to 0.94 for staygreen, depending on the number of tested parents of the single cross and genomic prediction method used. The genomic estimated general and specific combining abilities showed an advantage over genomic covariances among single crosses when one or both parents of the single cross were untested. Overall, our results suggest that genomic prediction of single crosses in the early stages of a hybrid breeding pipeline holds great potential to redesign hybrid breeding and increase its efficiency.

  10. Accelerators for critical experiments involving single-particle upset in solid-state microcircuits

    Science.gov (United States)

    Zoutendyk, J. A.

    1985-01-01

    Charged-particle interactions in microelectronic circuit chips (integrated circuits) present a particularly insidious problem for solid-state electronic systems due to the generation of soft errors or single-particle event upset (SEU) by either cosmic rays or other radiation sources. Particle accelerators are used to provide both light and heavy ions in order to assess the propensity of integrated circuit chips for SEU. Critical aspects of this assessment involve the ability to analytically model SEU for the prediction of error rates in known radiation environments. In order to accurately model SEU, the measurement and prediction of energy deposition in the form of an electron-hole plasma generated along an ion track is of paramount importance. This requires the use of accelerators which allow for ease in both energy control (change of energy) and change of ion species. This and other aspects of ion-beam control and diagnostics (e.g., uniformity and flux) are of critical concern for the experimental verification of theoretical SEU models.

  11. Accelerated rescaling of single Monte Carlo simulation runs with the Graphics Processing Unit (GPU).

    Science.gov (United States)

    Yang, Owen; Choi, Bernard

    2013-01-01

    To interpret fiber-based and camera-based measurements of remitted light from biological tissues, researchers typically use analytical models, such as the diffusion approximation to light transport theory, or stochastic models, such as Monte Carlo modeling. To achieve rapid (ideally real-time) measurement of tissue optical properties, especially in clinical situations, there is a critical need to accelerate Monte Carlo simulation runs. In this manuscript, we report on our approach using the Graphics Processing Unit (GPU) to accelerate rescaling of single Monte Carlo runs to calculate rapidly diffuse reflectance values for different sets of tissue optical properties. We selected MATLAB to enable non-specialists in C and CUDA-based programming to use the generated open-source code. We developed a software package with four abstraction layers. To calculate a set of diffuse reflectance values from a simulated tissue with homogeneous optical properties, our rescaling GPU-based approach achieves a reduction in computation time of several orders of magnitude as compared to other GPU-based approaches. Specifically, our GPU-based approach generated a diffuse reflectance value in 0.08ms. The transfer time from CPU to GPU memory currently is a limiting factor with GPU-based calculations. However, for calculation of multiple diffuse reflectance values, our GPU-based approach still can lead to processing that is ~3400 times faster than other GPU-based approaches.

  12. Experimental setup for Single Event Effects at the São Paulo 8UD Pelletron Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Aguiar, V.A.P. [Instituto de Física da Universidade de São Paulo, São Paulo, SP (Brazil); Added, N., E-mail: nemitala@if.usp.br [Instituto de Física da Universidade de São Paulo, São Paulo, SP (Brazil); Medina, N.H.; Macchione, E.L.A.; Tabacniks, M.H.; Aguirre, F.R. [Instituto de Física da Universidade de São Paulo, São Paulo, SP (Brazil); Silveira, M.A.G.; Santos, R.B.B. [Centro Universitário da FEI, São Bernardo do Campo, SP (Brazil); Seixas, L.E. [Centro de Tecnologia da Informação Renato Archer, Campinas, SP (Brazil)

    2014-08-01

    In this work we present an experimental setup mounted in one of the beam lines at the São Paulo 8UD Pelletron Accelerator in order to study Single Event Effects in electronic devices. The basic idea is to use elastic scattering collisions to achieve a low-flux with a high-uniformity ion beam to irradiate several devices. {sup 12}C, {sup 16}O, {sup 28}Si, {sup 35}Cl and {sup 63}Cu beams were used to test the experimental setup. In this system it is possible to use efficiently LET values of 17 MeV/mg/cm{sup 2} for an external beam arrangement and up to 32 MeV/mg/cm{sup 2} for in-vacuum irradiation.

  13. Experimental setup for Single Event Effects at the São Paulo 8UD Pelletron Accelerator

    Science.gov (United States)

    Aguiar, V. A. P.; Added, N.; Medina, N. H.; Macchione, E. L. A.; Tabacniks, M. H.; Aguirre, F. R.; Silveira, M. A. G.; Santos, R. B. B.; Seixas, L. E.

    2014-08-01

    In this work we present an experimental setup mounted in one of the beam lines at the São Paulo 8UD Pelletron Accelerator in order to study Single Event Effects in electronic devices. The basic idea is to use elastic scattering collisions to achieve a low-flux with a high-uniformity ion beam to irradiate several devices. 12C, 16O, 28Si, 35Cl and 63Cu beams were used to test the experimental setup. In this system it is possible to use efficiently LET values of 17 MeV/mg/cm2 for an external beam arrangement and up to 32 MeV/mg/cm2 for in-vacuum irradiation.

  14. Single-session versus staged procedures for elective multivessel percutaneous coronary intervention.

    Science.gov (United States)

    Toyota, Toshiaki; Morimoto, Takeshi; Shiomi, Hiroki; Yamaji, Kyohei; Ando, Kenji; Ono, Koh; Shizuta, Satoshi; Saito, Naritatsu; Kato, Takao; Kaji, Shuichiro; Furukawa, Yutaka; Nakagawa, Yoshihisa; Kadota, Kazushige; Horie, Minoru; Kimura, Takeshi

    2017-11-16

    To clarify the effect of single-session multivessel percutaneous coronary intervention (PCI) strategy relative to the staged multivessel strategy on clinical outcomes in patients with stable coronary artery disease (CAD) or non-ST-elevation acute coronary syndrome. In the Coronary REvascularisation Demonstrating Outcome Study in Kyoto PCI/coronary artery bypass grafting registry cohort-2, there were 2018 patients who underwent elective multivessel PCI. Primary outcome measure was composite of all-cause death, myocardial infarction and stroke at 5-year follow-up. Single-session multivessel PCI and staged multivessel PCI were performed in 707 patients (35.0%) and 1311 patients (65.0%), respectively. The cumulative 5-year incidence of and adjusted risk for the primary outcome measure were not significantly different between the single-session and staged groups (26.7% vs 23.0%, p=0.45; HR 0.91, 95% CI 0.72 to 1.16, p=0.47). The 30-day incidence of all-cause death was significantly higher in the single-session group than in the staged group (1.1% vs 0.2%, p=0.009). However, the causes of death in 11 patients who died within 30 days were generally not related to the procedural complications, but related to the serious clinical status before PCI. For the subgroup analyses including age, gender, extent of CAD, severe chronic kidney disease and heart failure, there was no significant interaction between the subgroup factors and the effect of the single-session strategy relative to the staged strategy for the primary outcome measure. The single-session multivessel PCI strategy was associated with at least comparable 5-year clinical outcomes compared with the staged multivessel PCI, although the prevalence of the single-session strategy was low in the present study. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. Single-stage posterior transforaminal lumbar interbody fusion, debridement, limited decompression, 3-column reconstruction, and posterior instrumentation in surgical treatment for single-segment lumbar spinal tuberculosis

    OpenAIRE

    Zeng, Hao; Wang, Xiyang; Zhang, Penghui; Peng, Wei; Zhang, Yupeng; Liu, Zheng

    2015-01-01

    Objective: The aim of this study is to determine the feasibility and efficacy of surgical management of single-segment lumbar spinal tuberculosis (TB) by using single-stage posterior transforaminal lumbar interbody fusion, debridement, limited decompression, 3-column reconstruction, and posterior instrumentation.Methods: Seventeen cases of single-segment lumbar TB were treated with single-stage posterior transforaminal lumbar interbody fusion, debridement, limited decompression, 3-column reco...

  16. Efficacy of single-stage and two-stage Fowler–Stephens laparoscopic orchidopexy in the treatment of intraabdominal high testis

    Directory of Open Access Journals (Sweden)

    Chang-Yuan Wang

    2017-11-01

    Conclusion: In the case of testis with good collateral circulation, single-stage F-S laparoscopic orchidopexy had the same safety and efficacy as the two-stage F-S procedure. Surgical options should be based on comprehensive consideration of intraoperative testicular location, testicular ischemia test, and collateral circumstances surrounding the testes. Under the appropriate conditions, we propose single-stage F-S laparoscopic orchidopexy be preferred. It may be appropriate to avoid unnecessary application of the two-stage procedure that has a higher cost and causes more pain for patients.

  17. Single-stage reconstruction of flexor tendons with vascularized tendon transfers.

    Science.gov (United States)

    Cavadas, P C; Pérez-García, A; Thione, A; Lorca-García, C

    2015-03-01

    The reconstruction of finger flexor tendons with vascularized flexor digitorum superficialis (FDS) tendon grafts (flaps) based on the ulnar vessels as a single stage is not a popular technique. We reviewed 40 flexor tendon reconstructions (four flexor pollicis longus and 36 finger flexors) with vascularized FDS tendon grafts in 38 consecutive patients. The donor tendons were transferred based on the ulnar vessels as a single-stage procedure (37 pedicled flaps, three free flaps). Four patients required composite tendon and skin island transfer. Minimum follow-up was 12 months, and functional results were evaluated using a total active range of motion score. Multiple linear regression analysis was performed to evaluate the factors that could be associated with the postoperative total active range of motion. The average postoperative total active range of motion (excluding the thumbs) was 178.05° (SD 50°). The total active range of motion was significantly lower for patients who were reconstructed with free flaps and for those who required composite tendon and skin island flap. Age, right or left hand, donor/motor tendon and pulley reconstruction had no linear effect on total active range of motion. Overall results were comparable with a published series on staged tendon grafting but with a lower complication rate. Vascularized pedicled tendon grafts/flaps are useful in the reconstruction of defects of finger flexor tendons in a single stage, although its role in the reconstructive armamentarium remains to be clearly established. © The Author(s) 2014.

  18. [Study on Sleep Staging Based on Support Vector Machines and Feature Selection in Single Channel Electroencephalogram].

    Science.gov (United States)

    Lin, Xiujing; Xia, Yongming; Qian, Songrong

    2015-06-01

    Sleep electroencephalogram (EEG) is an important index in diagnosing sleep disorders and related diseases. Manual sleep staging is time-consuming and often influenced by subjective factors. Existing automatic sleep staging methods have high complexity and a low accuracy rate. A sleep staging method based on support vector machines (SVM) and feature selection using single channel EEG single is proposed in this paper. Thirty-eight features were extracted from the single channel EEG signal. Then based on the feature selection method F-Score's definition, it was extended to multiclass with an added eliminate factor in order to find proper features, which were used as SVM classifier inputs. The eliminate factor was adopted to reduce the negative interaction of features to the result. Research on the F-Score with an added eliminate factor was further accomplished with the data from a standard open source database and the results were compared with none feature selection and standard F-Score feature selection. The results showed that the present method could effectively improve the sleep staging accuracy and reduce the computation time.

  19. Single-stage Modified Duhamel procedure for Hirschsprung′s disease : Our experience

    Directory of Open Access Journals (Sweden)

    Paras R Kothari

    2012-01-01

    Full Text Available Introduction: Primary single-stage pull-through for Hirschsprung′s disease (HD has been reported to give comparable surgical outcomes to staged operations with less morbidity. Herein, we present our experience with single-stage Modified Duhamel procedure for management of HD. Patients and Methods: This was a review of 48 cases of HD who underwent single-stage Modified Duhamel procedure without a protective colostomy. Results: The age at surgery ranged from 6 months to 10 years (median - 9 months, mean - 2.3 years. The average weight of the child was 7.2 kg (range, 4.9-22 kg. 38 (79.2% patients had classical rectosigmoid HD, the rest being long segment HD (the proximal most level being the splenic flexure. The average duration of surgery was 175 minutes (range, 130-245 minutes. The average blood loss was 45 ml. The average hospital stay was 7.2 days (range: 6-10 days. The major postoperative complications (n=3 included postoperative adhesive intestinal obstruction, anastomotic leak and persistent constipation due to residual aganglionosis. Each required a re-exploration. Minor complications included surgical site infection (n=3 and post-operative enterocolitis (n=3, which were managed conservatively. Six patients had constipation for a limited period post-operatively. All patients have a satisfactory functional outcome and normal development and growth. Conclusions: For HD, we recommend that single-stage Modified Duhamel procedure should be the preferred approach in view of its low morbidity, satisfactory functional outcome and avoidance of stoma, multiple surgeries and economic benefit in view of decreased hospital stay.

  20. Single-stage electrohydraulic servosystem for actuating on airflow valve with frequencies to 500 hertz

    Science.gov (United States)

    Webb, J. A., Jr.; Mehmed, O.; Lorenzo, C. F.

    1980-01-01

    An airflow valve and its electrohydraulic actuation servosystem are described. The servosystem uses a high-power, single-stage servovalve to obtain a dynamic response beyond that of systems designed with conventional two-stage servovalves. The electrohydraulic servosystem is analyzed and the limitations imposed on system performance by such nonlinearities as signal saturations and power limitations are discussed. Descriptions of the mechanical design concepts and developmental considerations are included. Dynamic data, in the form of sweep-frequency test results, are presented and comparison with analytical results obtained with an analog computer model is made.

  1. Surgical reconstruction of pressure ulcer defects: a single- or two-stage procedure?

    LENUS (Irish Health Repository)

    Laing, Tereze A

    2012-02-01

    BACKGROUND: The surgical management of pressure ulcers traditionally involved staged procedures, with initial debridement of necrotic or infected material followed by reconstruction at a later date when the wound was deemed viable and free of gross infection. However, over the past decade, it has been suggested that a single-stage procedure, combining initial debridement and definitive reconstruction, may provide advantages over staged surgery. We present our experience with the staged approach and review the current evidence for both methods. SUBJECTS AND SETTINGS: : We reviewed medical records of all patients referred to our service for pressure ulcer management between October 2001 and October 2007. The National Rehabilitation Hospital is the national center in Ireland for primary rehabilitation of adults and children suffering from spinal and brain injury, serving patients locally and from around the country. METHODS: All subjects who were managed surgically underwent a 2-stage procedure, with initial debridement and subsequent reconstruction. The main outcome measures were length of hospital stay, postoperative morbidity and mortality, and time to complete ulcer healing. RESULTS: Forty-one of 108 patients with 58 pressure ulcers were managed surgically. All patients underwent initial surgical debridement and 20 patients underwent subsequent pressure ulcer reconstruction. Postreconstructive complications occurred in 5 patients (20%). The mean time to complete ulcer healing was 17.4 weeks. Partial flap necrosis occurred in 3 patients, but there were no episodes of flap failure. CONCLUSIONS: We achieved favorable results with a 2-stage reconstruction technique and suggest that the paucity of evidence related to single-stage procedures does not support a change in surgical management.

  2. Frequency-Domain Tomography for Single-shot, Ultrafast Imaging of Evolving Laser-Plasma Accelerators

    Science.gov (United States)

    Li, Zhengyan; Zgadzaj, Rafal; Wang, Xiaoming; Downer, Michael

    2011-10-01

    Intense laser pulses propagating through plasma create plasma wakefields that often evolve significantly, e.g. by expanding and contracting. However, such dynamics are known in detail only through intensive simulations. Laboratory visualization of evolving plasma wakes in the ``bubble'' regime is important for optimizing and scaling laser-plasma accelerators. Recently snap-shots of quasi-static wakes were recorded using frequency-domain holography (FDH). To visualize the wake's evolution, we have generalized FDH to frequency-domain tomography (FDT), which uses multiple probes propagating at different angles with respect to the pump pulse. Each probe records a phase streak, imprinting a partial record of the evolution of pump-created structures. We then topographically reconstruct the full evolution from all phase streaks. To prove the concept, a prototype experiment visualizing nonlinear index evolution in glass is demonstrated. Four probes propagating at 0, 0.6, 2, 14 degrees to the index ``bubble'' are angularly and temporally multiplexed to a single spectrometer to achieve cost-effective FDT. From these four phase streaks, an FDT algorithm analogous to conventional CT yields a single-shot movie of the pump's self-focusing dynamics.

  3. Advocacy for the Archives and History Office of the SLAC National Accelerator Laboratory: Stages and Methods

    Energy Technology Data Exchange (ETDEWEB)

    Deken, Jean Marie; /SLAC

    2009-06-19

    Advocating for the good of the SLAC Archives and History Office (AHO) has not been a one-time affair, nor has it been a one-method procedure. It has required taking time to ascertain the current and perhaps predict the future climate of the Laboratory, and it has required developing and implementing a portfolio of approaches to the goal of building a stronger archive program by strengthening and appropriately expanding its resources. Among the successful tools in the AHO advocacy portfolio, the Archives Program Review Committee has been the most visible. The Committee and the role it serves as well as other formal and informal advocacy efforts are the focus of this case study My remarks today will begin with a brief introduction to advocacy and outreach as I understand them, and with a description of the Archives and History Office's efforts to understand and work within the corporate culture of the SLAC National Accelerator Laboratory. I will then share with you some of the tools we have employed to advocate for the Archives and History Office programs and activities; and finally, I will talk about how well - or badly - those tools have served us over the past decade.

  4. Instruments for radiation measurement in life sciences (4). 7. Application of accelerator mass spectrometry for drug development. Human mass balance studies at discovery stage

    International Nuclear Information System (INIS)

    Miyaoka, Teiji

    2005-01-01

    Following the recent trend of Position Paper issued from European Agency for the Evaluation of Medicinal Products on the non-clinical safety studies to support clinical trials with a single micro dose, human mass balance studies at discovery stages were made with special interest in using AMS (accelerator mass spectrometry) with a small amount of hot (radioisotope-labeled) drug. This method was found to be effective for the purpose of screening in the clinical study for pharmaceutical development. To show an example of the test, 5, 50, 500μg/body of C14-ARA (α1A adrenoreceptor antagonist, 50 nCi or 1.85 kBq/body/dose) were given (cross over) to several persons to be inspected and C14-quantity in the blood plasma or urine was determined with AMS until after 168 hours or so. The results of the present experiment demonstrate that human mass balance study at discovery stages is possible with ultra high sensitive measuring systems such as AMS and PET (positron emission tomography). (S. Ohno)

  5. Validation of a PC based program for single stage absorption heat pump

    Science.gov (United States)

    Zaltash, A.; Ally, M. R.

    1991-09-01

    An interactive computer code was developed to evaluate single stage absorption heat pump performance for temperature amplifier and heat amplifier modes using water as the refrigerant. This program performs the cycle calculations for single stage cycles based on the polynomial expressions developed to correlate experimental vapor-liquid-equilibrium (VLE) and specific enthalpy-concentration data for LiBr/water and (Li, K, Na)NO3 water systems as well as the properties of pure water. The operating parameters obtained by this program were tested against mass and energy balances in documented cases and the results show that the maximum deviation between coefficient of performance (COP) values obtained by this software and the ones previously calculated is less than 3 percent. In addition, this program was used to study the effect of solution temperature leaving the absorber on the other operating parameters. This type of analysis could be used to improve and optimize cycle design.

  6. Grid Integration of Single Stage Solar PV System using Three-level Voltage Source Converter

    Science.gov (United States)

    Hussain, Ikhlaq; Kandpal, Maulik; Singh, Bhim

    2016-08-01

    This paper presents a single stage solar PV (photovoltaic) grid integrated power generating system using a three level voltage source converter (VSC) operating at low switching frequency of 900 Hz with robust synchronizing phase locked loop (RS-PLL) based control algorithm. To track the maximum power from solar PV array, an incremental conductance algorithm is used and this maximum power is fed to the grid via three-level VSC. The use of single stage system with three level VSC offers the advantage of low switching losses and the operation at high voltages and high power which results in enhancement of power quality in the proposed system. Simulated results validate the design and control algorithm under steady state and dynamic conditions.

  7. Single-stage osseointegrated implants for nasal prosthodontic rehabilitation: A clinical report.

    Science.gov (United States)

    de Carvalho, Bruna M D F; Freitas-Pontes, Karina M; de Negreiros, Wagner A; Verde, Marcus A R L

    2015-08-01

    Malignant tumors in the nasal region may be treated by means of invasive surgical procedures, with large facial losses. Nasal prostheses, retained by osseointegrated facial implants, instead of plastic surgery, will, in most patients, offer good biomechanical and cosmetic results. This clinical report describes the prosthetic rehabilitation of a patient with nasal cancer who had the entire nasal vestibule removed in a single-stage surgical procedure in order to shorten the rehabilitation time. The nasal prosthesis was built on a 3-magnet bar and was made of platinum silicone with intrinsic pigmentation, thereby restoring the patient's appearance and self-esteem. The authors concluded that single-stage implants may reduce the rehabilitation time to as little as 1 month, and the correct use of materials and techniques may significantly improve the nasal prosthesis. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  8. Investigation of Single-Stage Modified Turbine of Mark 25 Torpedo Power Plant

    Science.gov (United States)

    Hoyt, Jack W.

    1947-01-01

    Efficiency investigations have been made on a single-stage modification of the turbine of a Mark 25 aerial torpedo to determine the performance of the unit with five different turbine nozzles. The output of the turbine blades was computed by analyzing the windage and mechanical-friction losses of the unit. The turbine was faund to be most efficient with a cast nozzle having sharp-edged inlets to the nine nozzle ports. An analysis af the effectiveness af the first and second stages of the standard Mark 25 torpedo turbine indicates that the first- stage turbine contributes nearly all the brake power produced at blade-jet speed ratios above 0.26.

  9. [Single-stage bilateral Pemberton's pericapsular osteotomy in bilateral developmental dysplasia of the hip].

    Science.gov (United States)

    Zorer, Gazi; Bagatur, A Erdem

    2002-01-01

    This study was designed to evaluate the results of single-stage bilateral Pemberton's pericapsular osteotomy with or without open reduction and to demonstrate its advantages over two separate consecutive interventions in bilateral developmental dysplasia of the hip (DDH). This prospective study included 20 patients (14 girls, 6 boys; mean age 30 months; range 12 to 60 months) with bilateral DDH, who underwent single-stage bilateral Pemberton's pericapsular osteotomy with (14 patients, group A1) or without (6 patients, group A2) open reduction. Twenty patients (16 girls, 4 boys; mean age 24 months; range 13 to 47 months) with unilateral DDH, who underwent Pemberton's pericapsular osteotomy with (12 patients, group B1) or without (8 patients, group B2) open reduction were enrolled into the study as controls. Single- and two-stage procedures were compared with regard to improvement in the acetabular index, complications, mean duration of anesthesia, perioperative need for blood transfusion, length of hospital stay, initiation of walking, overall cost of antibiotic prophylaxis, and total hospital charge. There were no significant differences between A1 and B1, A2 and B2 groups with respect to mean age, gender, pre- and postoperative acetabular indices, and recovery times. However, duration of anesthesia, length of hospital stay, cost of antibiotic prophylaxis, and total hospital charges differed significantly. The amount of blood transfusion differed significantly only between groups A1 and B1. The length of hospital stay and cost of antibiotic prophylaxis in group A2 was twice as much as that of group B2. Increases in other parameters ranged between 22% to 37%. No early or late complications were encountered. Single-stage bilateral Pemberton's pericapsular osteotomy in patients with bilateral DDH seems to have significant advantages over two separate consecutive interventions. However, increased risks of bilateral osteotomies require that sufficiently equipped and

  10. Advanteges of using Two-Switch Forward in Single-Stage Power Factor Corrected Power Supplies

    DEFF Research Database (Denmark)

    Petersen, Lars

    2000-01-01

    A single-Stage power factor corrected power supply using a two-switch forward is proposed to increase efficiency. The converter is operated in the DCM (Discontinues Conduction Mode). This will insure the intermediate DC-bus to be controlled only by means of circuit parameters and therefore...... power supply has been implemented. The measured efficiency and power factor are about 87% and 0.96 respectively....

  11. The first preliminary experiments on an 84 GHz gyrotron with a single-stage depressed collector

    International Nuclear Information System (INIS)

    Shimozuma, T.; Sato, M.; Takita, Y.

    1997-10-01

    We fabricated and tested an 84GHz gyrotron with a single-stage depressed collector. The gyrotron has a high-voltage insulating section made of a low loss silicon nitride composite. In this preliminary experiment in the depressed collector configuration, we obtained 591kW, 41% operation with a depression voltage of 22.5kV. Access to the higher efficiency region was inhibited by an increase in anode current. (author)

  12. Adaptive kanban control mechanism for a single-stage hybrid system

    Science.gov (United States)

    Korugan, Aybek; Gupta, Surendra M.

    2002-02-01

    In this paper, we consider a hybrid manufacturing system with two discrete production lines. Here the output of either production line can satisfy the demand for the same type of product without any penalties. The interarrival times for demand occurrences and service completions are exponentially distributed i.i.d. variables. In order to control this type of manufacturing system we suggest a single stage pull type control mechanism with adaptive kanbans and state independent routing of the production information.

  13. Clinical and radiologic evaluation of 2-stage IMZ implants placed in a single-stage procedure : 2-year results of a prospective comparative study

    NARCIS (Netherlands)

    Heydenrijk, K; Raghoebar, GM; Meijer, HJA; Stegenga, B

    2003-01-01

    Purpose: The aim of this study was to evaluate the feasibility of using a 2-stage implant system in a single-stage procedure and to study the impact of the microgap between the implant and the abutment. Materials and Methods: Sixty edentulous patients (Cawood class V or VI) participated in this

  14. Two-stage single-volume exchange transfusion in severe hemolytic disease of the newborn.

    Science.gov (United States)

    Abbas, Wael; Attia, Nayera I; Hassanein, Sahar M A

    2012-07-01

    Evaluation of two-stage single-volume exchange transfusion (TSSV-ET) in decreasing the post-exchange rebound increase in serum bilirubin level, with subsequent reduction of the need for repeated exchange transfusions. The study included 104 neonates with hyperbilirubinemia needing exchange transfusion. They were randomly enrolled into two equal groups, each group comprised 52 neonates. TSSV-ET was performed for the 52 neonates and the traditional single-stage double-volume exchange transfusion (SSDV-ET) was performed to 52 neonates. TSSV-ET significantly lowered rebound serum bilirubin level (12.7 ± 1.1 mg/dL), compared to SSDV-ET (17.3 ± 1.7 mg/dL), p < 0.001. Need for repeated exchange transfusions was significantly lower in TSSV-ET group (13.5%), compared to 32.7% in SSDV-ET group, p < 0.05. No significant difference was found between the two groups as regards the morbidity (11.5% and 9.6%, respectively) and the mortality (1.9% for both groups). Two-stage single-volume exchange transfusion proved to be more effective in reducing rebound serum bilirubin level post-exchange and in decreasing the need for repeated exchange transfusions.

  15. Nitrite reduction and methanogenesis in a single-stage UASB reactor.

    Science.gov (United States)

    Borges, L I; López-Vazquez, C M; García, H; van Lier, J B

    2015-01-01

    In this study, nitrite reduction and methanogenesis in a single-stage upflow anaerobic sludge blanket (UASB) reactor was investigated, using high-strength synthetic domestic wastewater as substrate. To assess long-term effects and evaluate the mechanisms that allow successful nitrite reduction and methanogenesis in a single-stage UASB, sludge was exposed to relatively high nitrite loading rates (315 ± 13 mgNO(2)(-)-N/(l.d)), using a chemical oxygen demand (COD) to nitrogen ratio of 18 gCOD/gNO(2)(-)-N, and an organic loading rate of 5.4 ± 0.2 gCOD/(l.d). In parallel, the effects of sludge morphology on methanogenesis inhibition were studied by performing short-term batch activity tests at different COD/NO(2)(-)-N ratios with anaerobic sludge samples. In long-term tests, denitrification was practically complete and COD removal efficiency did not change significantly after nitrite addition. Furthermore, methane production only decreased by 13%, agreeing with the reducing equivalents requirement for complete NO(2)(-) reduction to N₂. Apparently, the spatial separation of denitrification and methanogenesis zones inside the UASB reactor allowed nitrite reduction and methanogenesis to occur at the same moment. Batch tests showed that granules seem to protect methanogens from nitrite inhibition, probably due to transport limitations. Combined COD and N removal via nitrite in a single-stage UASB reactor could be a feasible technology to treat high-strength domestic wastewater.

  16. Red Mud Catalytic Pyrolysis of Pinyon Juniper and Single-Stage Hydrotreatment of Oils

    Energy Technology Data Exchange (ETDEWEB)

    Agblevor, Foster A.; Elliott, Douglas C.; Santosa, Daniel M.; Olarte, Mariefel V.; Burton, Sarah D.; Swita, Marie; Beis, Sedat H.; Christian, Kyle; Sargent, Brandon

    2016-10-20

    Pinyon juniper biomass feedstocks, which cover a large acreage of rangeland in the western United States, are being eradicated and, therefore, considered as a convenient biomass feedstock for biofuel production. Pinyon juniper whole biomass (wood, bark, and leaves) were pyrolyzed in a pilot-scale bubbling fluidized-bed reactor at 450 °C, and the noncondensable gases were recycled to fluidize the reactor. Red mud was used as the in situ catalyst for the pyrolysis of the pinyon juniper biomass. The pyrolysis products were condensed in three stages, and products were analyzed for physicochemical properties. The condenser oil formed two phases with the aqueous fraction, whereas the electrostatic precipitator oils formed a single phase. The oil pH was 3.3; the higher heating value (HHV) was 28 MJ/kg; and the viscosity was less than 100 cP. There was a direct correlation between the viscosity of the oils and the alcohol/ether content of the oils, and this was also related to the aging rate of the oils. The catalytic pyrolysis oils were hydrotreated in a continuous single-stage benchtop hydrotreater to produce hydrocarbon fuels with a density of 0.80$-$0.82 cm3/g. The hydrotreater ran continuously for over 300 h with no significant catalyst deactivation or coke formation. This is the first time that such a long single-stage hydrotreatment has been demonstrated on biomass catalytic pyrolysis oils.

  17. Performance characteristics of an excimer laser (XeCl) with single-stage magnetic pulse compression

    Science.gov (United States)

    Varshnay, N. K.; Singh, A.; Benerji, N. S.

    2017-02-01

    Performance characteristics of an excimer laser (XeCl) with single-stage magnetic pulse compression suitable for material processing applications are presented here. The laser incorporates in-built compact gas circulation and gas cooling to ensure fresh gas mixture between the electrodes for repetitive operation. A magnetically coupled tangential blower is used for gas circulation inside the laser chamber for repetitive operation. The exciter consists of C-C energy transfer circuit and thyratron is used as a high-voltage main switch with single-stage magnetic pulse compression (MPC) between thyratron and the laser electrodes. Low inductance of the laser head and uniform and intense pre-ionization are the main features of the electric circuit used in the laser. A 250 ns rise time voltage pulse was compressed to 100 ns duration with a single-stage magnetic pulse compressor using Ni-Zn ferrite cores. The laser can generate about 150 mJ at ˜100 Hz rep-rate reliably from a discharge volume of 100 cm 3. 2D spatial laser beam profile generated is presented here. The profile shows that the laser beam is completely filled with flat-top which is suitable for material processing applications. The SEM image of the microhole generated on copper target is presented here.

  18. New current control based MPPT technique for single stage grid connected PV systems

    International Nuclear Information System (INIS)

    Jain, Sachin; Agarwal, Vivek

    2007-01-01

    This paper presents a new maximum power point tracking algorithm based on current control for a single stage grid connected photovoltaic system. The main advantage of this algorithm comes from its ability to predict the approximate amplitude of the reference current waveform or power that can be derived from the PV array with the help of an intermediate variable β. A variable step size for the change in reference amplitude during initial tracking helps in fast tracking. It is observed that if the reference current amplitude is greater than the array capacity, the system gets unstable (i.e. moves into the positive slope region of the p-v characteristics of the array). The proposed algorithm prevents the PV system from entering the positive slope region of the p-v characteristics. It is also capable of restoring stability if the system goes unstable due to a sudden environmental change. The proposed algorithm has been tested on a new single stage grid connected PV configuration recently developed by the authors to feed sinusoidal current into the grid. The system is operated in a continuous conduction mode to realize advantages such as low device current stress, high efficiency and low EMI. A fast MPPT tracker with single stage inverter topology operating in CCM makes the overall system highly efficient. Specific cases of the system, operating in just discontinuous current mode and discontinuous current mode and their relative merits and demerits are also discussed

  19. Addition of seaweed and bentonite accelerates the two-stage composting of green waste.

    Science.gov (United States)

    Zhang, Lu; Sun, Xiangyang

    2017-11-01

    Green waste (GW) is an important recyclable resource, and composting is an effective technology for the recycling of organic solid waste, including GW. This study investigated the changes in physical and chemical characteristics during the two-stage composting of GW with or without addition of seaweed (SW, Ulva ohnoi) (at 0, 35, and 55%) and bentonite (BT) (at 0.0, 2.5%, and 4.5%). During the bio-oxidative phase, the combined addition of SW and BT improved the physicochemical conditions, increased the respiration rate and enzyme activities, and decreased ammonia and nitrous oxide emissions. The combination of SW and BT also enhanced the quality of the final compost in terms of water-holding capacity, porosity, particle-size distribution, water soluble organic carbon/organic nitrogen ratio, humification, nutrient content, and phytotoxicity. The best quality compost, which matured in only 21days, was obtained with 35% SW and 4.5% BT. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Monte Carlo Error Analysis Applied to Core Formation: The Single-stage Model Revived

    Science.gov (United States)

    Cottrell, E.; Walter, M. J.

    2009-12-01

    The last decade has witnessed an explosion of studies that scrutinize whether or not the siderophile element budget of the modern mantle can plausibly be explained by metal-silicate equilibration in a deep magma ocean during core formation. The single-stage equilibrium scenario is seductive because experiments that equilibrate metal and silicate can then serve as a proxy for the early earth, and the physical and chemical conditions of core formation can be identified. Recently, models have become more complex as they try to accommodate the proliferation of element partitioning data sets, each of which sets its own limits on the pressure, temperature, and chemistry of equilibration. The ability of single stage models to explain mantle chemistry has subsequently been challenged, resulting in the development of complex multi-stage core formation models. Here we show that the extent to which extant partitioning data are consistent with single-stage core formation depends heavily upon (1) the assumptions made when regressing experimental partitioning data (2) the certainty with which regression coefficients are known and (3) the certainty with which the core/mantle concentration ratios of the siderophile elements are known. We introduce a Monte Carlo algorithm coded in MATLAB that samples parameter space in pressure and oxygen fugacity for a given mantle composition (nbo/t) and liquidus, and returns the number of equilibrium single-stage liquidus “solutions” that are permissible, taking into account the uncertainty in regression parameters and range of acceptable core/mantle ratios. Here we explore the consequences of regression parameter uncertainty and the impact of regression construction on model outcomes. We find that the form of the partition coefficient (Kd with enforced valence state, or D) and the handling of the temperature effect (based on 1-atm free energy data or high P-T experimental observations) critically affects model outcomes. We consider the most

  1. Preoperative Accelerated Partial Breast Irradiation for Early-Stage Breast Cancer: Preliminary Results of a Prospective, Phase 2 Trial

    International Nuclear Information System (INIS)

    Nichols, Elizabeth; Kesmodel, Susan B.; Bellavance, Emily; Drogula, Cynthia; Tkaczuk, Katherine; Cohen, Randi J.; Citron, Wendla; Morgan, Michelle; Staats, Paul; Feigenberg, Steven; Regine, William F.

    2017-01-01

    Purpose: To assess the feasibility of utilizing 3-dimensional conformal accelerated partial-breast irradiation (APBI) in the preoperative setting followed by standard breast-conserving therapy. Patients and Methods: This was a prospective trial testing the feasibility of preoperative APBI followed by lumpectomy for patients with early-stage invasive ductal breast cancer. Eligible patients had T1-T2 (<3 cm), N0 tumors. Patients received 38.5 Gy in 3.85-Gy fractions delivered twice daily. Surgery was performed >21 days after radiation therapy. Adjuvant therapy was given as per standard of care. Results: Twenty-seven patients completed treatment. With a median follow-up of 3.6 years (range, 0.5-5 years), there have been no local or regional failures. A complete pathologic response according to hematoxylin and eosin stains was seen in 4 patients (15%). There were 4 grade 3 seromas. Patient-reported cosmetic outcome was rated as good to excellent in 79% of patients after treatment. Conclusions: Preoperative 3-dimensional conformal radiation therapy−APBI is feasible and well tolerated in select patients with early-stage breast cancer, with no reported local recurrences and good to excellent cosmetic results. The pathologic response rates associated with this nonablative APBI dose regimen are particularly encouraging and support further exploration of this paradigm.

  2. Preoperative Accelerated Partial Breast Irradiation for Early-Stage Breast Cancer: Preliminary Results of a Prospective, Phase 2 Trial

    Energy Technology Data Exchange (ETDEWEB)

    Nichols, Elizabeth, E-mail: Enichols1@umm.edu [Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, Maryland (United States); Kesmodel, Susan B.; Bellavance, Emily; Drogula, Cynthia [Department of Surgical Oncology, University of Maryland School of Medicine, Baltimore, Maryland (United States); Tkaczuk, Katherine [Department of Medical Oncology, University of Maryland School of Medicine, Baltimore, Maryland (United States); Cohen, Randi J.; Citron, Wendla; Morgan, Michelle [Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, Maryland (United States); Staats, Paul [Department of Pathology, University of Maryland School of Medicine, Baltimore, Maryland (United States); Feigenberg, Steven; Regine, William F. [Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, Maryland (United States)

    2017-03-15

    Purpose: To assess the feasibility of utilizing 3-dimensional conformal accelerated partial-breast irradiation (APBI) in the preoperative setting followed by standard breast-conserving therapy. Patients and Methods: This was a prospective trial testing the feasibility of preoperative APBI followed by lumpectomy for patients with early-stage invasive ductal breast cancer. Eligible patients had T1-T2 (<3 cm), N0 tumors. Patients received 38.5 Gy in 3.85-Gy fractions delivered twice daily. Surgery was performed >21 days after radiation therapy. Adjuvant therapy was given as per standard of care. Results: Twenty-seven patients completed treatment. With a median follow-up of 3.6 years (range, 0.5-5 years), there have been no local or regional failures. A complete pathologic response according to hematoxylin and eosin stains was seen in 4 patients (15%). There were 4 grade 3 seromas. Patient-reported cosmetic outcome was rated as good to excellent in 79% of patients after treatment. Conclusions: Preoperative 3-dimensional conformal radiation therapy−APBI is feasible and well tolerated in select patients with early-stage breast cancer, with no reported local recurrences and good to excellent cosmetic results. The pathologic response rates associated with this nonablative APBI dose regimen are particularly encouraging and support further exploration of this paradigm.

  3. Sleep stage and obstructive apneaic epoch classification using single-lead ECG

    Directory of Open Access Journals (Sweden)

    Yılmaz Bülent

    2010-08-01

    Full Text Available Abstract Background Polysomnography (PSG is used to define physiological sleep and different physiological sleep stages, to assess sleep quality and diagnose many types of sleep disorders such as obstructive sleep apnea. However, PSG requires not only the connection of various sensors and electrodes to the subject but also spending the night in a bed that is different from the subject's own bed. This study is designed to investigate the feasibility of automatic classification of sleep stages and obstructive apneaic epochs using only the features derived from a single-lead electrocardiography (ECG signal. Methods For this purpose, PSG recordings (ECG included were obtained during the night's sleep (mean duration 7 hours of 17 subjects (5 men with ages between 26 and 67. Based on these recordings, sleep experts performed sleep scoring for each subject. This study consisted of the following steps: (1 Visual inspection of ECG data corresponding to each 30-second epoch, and selection of epochs with relatively clean signals, (2 beat-to-beat interval (RR interval computation using an R-peak detection algorithm, (3 feature extraction from RR interval values, and (4 classification of sleep stages (or obstructive apneaic periods using one-versus-rest approach. The features used in the study were the median value, the difference between the 75 and 25 percentile values, and mean absolute deviations of the RR intervals computed for each epoch. The k-nearest-neighbor (kNN, quadratic discriminant analysis (QDA, and support vector machines (SVM methods were used as the classification tools. In the testing procedure 10-fold cross-validation was employed. Results QDA and SVM performed similarly well and significantly better than kNN for both sleep stage and apneaic epoch classification studies. The classification accuracy rates were between 80 and 90% for the stages other than non-rapid-eye-movement stage 2. The accuracies were 60 or 70% for that specific stage

  4. Plasma gasification of refuse derived fuel in a single-stage system using different gasifying agents.

    Science.gov (United States)

    Agon, N; Hrabovský, M; Chumak, O; Hlína, M; Kopecký, V; Masláni, A; Bosmans, A; Helsen, L; Skoblja, S; Van Oost, G; Vierendeels, J

    2016-01-01

    The renewable evolution in the energy industry and the depletion of natural resources are putting pressure on the waste industry to shift towards flexible treatment technologies with efficient materials and/or energy recovery. In this context, a thermochemical conversion method of recent interest is plasma gasification, which is capable of producing syngas from a wide variety of waste streams. The produced syngas can be valorized for both energetic (heat and/or electricity) and chemical (ammonia, hydrogen or liquid hydrocarbons) end-purposes. This paper evaluates the performance of experiments on a single-stage plasma gasification system for the treatment of refuse-derived fuel (RDF) from excavated waste. A comparative analysis of the syngas characteristics and process yields was done for seven cases with different types of gasifying agents (CO2+O2, H2O, CO2+H2O and O2+H2O). The syngas compositions were compared to the thermodynamic equilibrium compositions and the performance of the single-stage plasma gasification of RDF was compared to that of similar experiments with biomass and to the performance of a two-stage plasma gasification process with RDF. The temperature range of the experiment was from 1400 to 1600 K and for all cases, a medium calorific value syngas was produced with lower heating values up to 10.9 MJ/Nm(3), low levels of tar, high levels of CO and H2 and which composition was in good agreement to the equilibrium composition. The carbon conversion efficiency ranged from 80% to 100% and maximum cold gas efficiency and mechanical gasification efficiency of respectively 56% and 95%, were registered. Overall, the treatment of RDF proved to be less performant than that of biomass in the same system. Compared to a two-stage plasma gasification system, the produced syngas from the single-stage reactor showed more favourable characteristics, while the recovery of the solid residue as a vitrified slag is an advantage of the two-stage set-up. Copyright

  5. Single-stage micro-scale solvent extraction in parallel microbore tubes using MDIMJ

    International Nuclear Information System (INIS)

    Darekar, Mayur; Singh, K.K.; Joshi, J.M.; Mukhopadhyay, S.; Shenoy, K.T.

    2016-01-01

    Single-stage micro-scale solvent extraction of U(VI) from simulated lean streams is explored using micro-scale contactor comprising of a MDIMJ (Monoblock Distributor with Integrated Microfluidic Junction) and PTFE microbore tubes. 30% (v/v) TBP in dodecane has been used as the extracting phase. The objective of the study is to demonstrate numbering up approach for scale-up of micro-scale extraction using indigenously conceptualized and fabricated MDIMJ. First the performance of MIDIMJ for equal flow distribution is tested. Then the effects of inlet flow rate and O/A ratio on stage efficiency and percentage extraction are studied. The experiments show that it is easy to scale-up single-stage micro-scale solvent extraction by using MDIMJ for numbering up approach. Maximum capacity tested is 4.8 LPH. With O/A = 2/1, more than 90% extraction is achieved in a very short contact time of less than 3s. The study thus demonstrates possibility of process intensification and easy scale-up of micro-scale solvent extraction

  6. Analysis of single photon detection in avalanche photodetectors with multi-gain-stage multiplication region.

    Science.gov (United States)

    Hosseinzadeh, Amir; Zavvari, Mahdi

    2017-02-20

    We report the design and analysis of a single photon avalanche detector (SPAD) with cascaded multiplication stages with asymmetric gain series for near-IR applications. The asymmetric gain profile allows us to selectively enhance the ionization coefficient for injected electrons and suppress the hole-initiated ionization by repetition of high and low field layers. The low field layer acts as a carrier relaxation region, which inhibits avalanche feedback between stages; hence, it is expected to have a lower dark count rate (DCR). The gain stage consists of three distinct layers with different electric fields, which can be adjusted by geometrical and mole fraction design. In this paper we study the effect of these layers' field and thickness on the single photon quantum efficiency (SPQE) and DCR of the proposed SPAD. Our results show that the high-field layer can better influence the performance of the detector rather than the others. In comparison with a conventional SPAD with a uniform multiplication region, our proposed structure shows lower DCR for a same SPQE.

  7. Attainability and minimum energy of single-stage membrane and membrane/distillation hybrid processes

    KAUST Repository

    Alshehri, Ali

    2014-12-01

    As an energy-efficient separation method, membrane technology has attracted more and more attentions in many challenging separation processes. The attainability and the energy consumption of a membrane process are the two basic fundamental questions that need to be answered. This report aims to use process simulations to find: (1) at what conditions a single-stage membrane process can meet the separation task that is defined by product purity and recovery ratio and (2) what are the most important parameters that determine the energy consumption. To perform a certain separation task, it was found that both membrane selectivity and pressure ratio exhibit a minimum value that is defined only by product purity and recovery ratio. The membrane/distillation hybrid system was used to study the energy consumption. A shortcut method was developed to calculate the minimum practical separation energy (MPSE) of the membrane process and the distillation process. It was found that the MPSE of the hybrid system is only determined by the membrane selectivity and the applied transmembrane pressure ratio in three stages. At the first stage when selectivity is low, the membrane process is not competitive to the distillation process. Adding a membrane unit to a distillation tower will not help in reducing energy. At the second medium selectivity stage, the membrane/distillation hybrid system can help reduce the energy consumption, and the higher the membrane selectivity, the lower is the energy. The energy conservation is further improved as pressure ratio increases. At the third stage when both selectivity and pressure ratio are high, the hybrid system will change to a single-stage membrane unit and this change will cause significant reduction in energy consumption. The energy at this stage keeps decreasing with selectivity at slow rate, but slightly increases with pressure ratio. Overall, the higher the membrane selectivity, the more the energy is saved. Therefore, the two

  8. A single-stage polymerase-based protocol for the introduction of deletions and insertions without subcloning.

    Science.gov (United States)

    Salerno, John C; Jones, Rachel J; Erdogan, Eda; Smith, Susan M E

    2005-03-01

    A single-stage polymerase-based procedure is described that allows extensive modifications of DNA. The version described here uses the QuikChange Site-Directed Mutagenesis System kit supplied by Stratagene. The original protocol is replaced by a single-stage method in which linear production of complementary strands is accomplished in separate single primer reactions. This has proved effective in introducing insertions and deletions into large gene/vector combinations without subcloning.

  9. Design and analysis of a radial diffuser in a single-stage centrifugal pump

    Directory of Open Access Journals (Sweden)

    Ming-Gao Tan

    2016-01-01

    Full Text Available Radial diffusers can improve the flow uniformity in pumps and affect the hydraulic performance of centrifugal pumps directly. The diffusion coefficient d is an important parameter in fluid machinery but it has seldom been used in the diffuser design of single-stage centrifugal pumps. To improve the design method of radial diffuser use in centrifugal pumps, the diffusion coefficient was introduced into the design of radial diffusers based on a single-arc hydraulic design method and it was found that the vane outlet angle, vane outlet thickness and vane number have a significant impact on the design results. A single-stage centrifugal pump with a radial diffuser was selected as the research model. The inner flow was simulated using the commercial computational fluid dynamics (CFD program CFX and verified by experiment. The results indicate that the head and efficiency of the pump are best when the vane outlet angle is 6°. The flow area decreases and the flow velocity at radial diffuser outlet increase when the outlet thickness is greater than 2 mm. The hydraulic loss is minimum and the head and efficiency are better when the vane number is 8 at different flow rates. So, the optimal range of the diffusion coefficient for the model pump is around 1.6 to 2. The study indicates that it is feasible to design radial diffusers according to the diffusion coefficient.

  10. Raman spectral dynamics of single cells in the early stages of growth factor stimulation.

    Science.gov (United States)

    Takanezawa, Sota; Morita, Shin-ichi; Ozaki, Yukihiro; Sako, Yasushi

    2015-05-05

    Cell fates change dynamically in response to various extracellular signals, including growth factors that stimulate differentiation and proliferation. The processes underlying cell-fate decisions are complex and often include large cell-to-cell variations, even within a clonal population in the same environment. To understand the origins of these cell-to-cell variations, we must detect the internal dynamics of single cells that reflect their changing chemical milieu. In this study, we used the Raman spectra of single cells to trace their internal dynamics during the early stages of growth factor stimulation. This method allows nondestructive and inclusive time-series analyses of chemical compositions of the same single cells. Applying a Gaussian mixture model to the major principal components of the single-cell Raman spectra, we detected the dynamics of the chemical states in MCF-7 cancer-derived cells in the absence and presence of differentiation and proliferation factors. The dynamics displayed characteristic variations according to the functions of the growth factors. In the differentiation pathway, the chemical composition changed directionally between multiple states, including both reversible and irreversible state transitions. In contrast, in the proliferation pathway, the chemical composition was homogenized into a single state. The differentiation factor also stimulated fluctuations in the chemical composition, whereas the proliferation factor did not. Copyright © 2015 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  11. Single Ion transient-IBIC analyses of semiconductor devices using a cryogenic temperature stage

    International Nuclear Information System (INIS)

    Laird, J.S.; Bardos, R.; Legge, G.J.F.; Jagadish, C.

    1998-01-01

    A new Transient - IBIC data acquisition and analysis system at MARC is described. A discussion on the need for single ion control and temperature control is also given. The recorded signal is used as the trigger for beam pulsing. The new cryostatic temperature control stage is introduced. Data is presented on line profiles across the edge of a Au-Si junction collected over the temperature range of 25-300K using a developed C-V and I-V variable temperature stage incorporating a liquid helium cryostat. It demonstrates the potential improvements in spatial resolution in materials of long lifetime by mapping on timing windows around the prompt charge component in the charge transient

  12. Multi-disciplinary design optimization and performance evaluation of a single stage transonic axial compressor

    International Nuclear Information System (INIS)

    Lee, Sae Il; Lee, Dong Ho; Kim, Kyu Hong; Park, Tae Choon; Lim, Byeung Jun; Kang, Young Seok

    2013-01-01

    The multidisciplinary design optimization method, which integrates aerodynamic performance and structural stability, was utilized in the development of a single-stage transonic axial compressor. An approximation model was created using artificial neural network for global optimization within given ranges of variables and several design constraints. The genetic algorithm was used for the exploration of the Pareto front to find the maximum objective function value. The final design was chosen after a second stage gradient-based optimization process to improve the accuracy of the optimization. To validate the design procedure, numerical simulations and compressor tests were carried out to evaluate the aerodynamic performance and safety factor of the optimized compressor. Comparison between numerical optimal results and experimental data are well matched. The optimum shape of the compressor blade is obtained and compared to the baseline design. The proposed optimization framework improves the aerodynamic efficiency and the safety factor.

  13. Single Ion transient-IBIC analyses of semiconductor devices using a cryogenic temperature stage

    Energy Technology Data Exchange (ETDEWEB)

    Laird, J.S.; Bardos, R.; Legge, G.J.F. [Melbourne Univ., Parkville, VIC (Australia). School of Physics; Jagadish, C. [Australian National Univ., Canberra, ACT (Australia). School of Physics, Electronic Materials Engineering

    1998-06-01

    A new Transient - IBIC data acquisition and analysis system at MARC is described. A discussion on the need for single ion control and temperature control is also given. The recorded signal is used as the trigger for beam pulsing. The new cryostatic temperature control stage is introduced. Data is presented on line profiles across the edge of a Au-Si junction collected over the temperature range of 25-300K using a developed C-V and I-V variable temperature stage incorporating a liquid helium cryostat. It demonstrates the potential improvements in spatial resolution in materials of long lifetime by mapping on timing windows around the prompt charge component in the charge transient. 2 figs.

  14. Minimally Invasive, Single-Stage, Multilevel Surgery for Obstructive Sleep Apnea in Asian Patients.

    Science.gov (United States)

    Lin, Hsin-Ching; Friedman, Michael; Chang, Hsueh-Wen; Bonzelaar, Lauren; Salapatas, Anna M; Lin, Meng-Chih; Huang, Kuo-Tung

    2017-02-01

    This study adds to the literature on the efficacy and low complication rates associated with minimally invasive, single-stage, multilevel surgery for Asian adults with obstructive sleep apnea (OSA) for whom conservative treatment had failed. Overall, our experience has produced results that make this procedure an option for select patients with snoring and OSA. To investigate the effectiveness and safety of anatomy-based, minimally invasive, single-stage, multilevel surgery in the treatment of OSA in an Asian population. This retrospective study enrolled 59 consecutive patients with OSA from a tertiary academic medical center who had multilevel obstruction and unsuccessful conservative therapy and then underwent minimally invasive, single-stage, multilevel surgery. The subjective symptoms and objective polysomnographic findings were collected preoperatively and at a minimum of 3 months postoperatively. The Global Patient Assessment questionnaire was used to assess patient satisfaction after minimally invasive, single-stage, multilevel surgery. Scores on the Epworth Sleepiness Scale and bed partner evaluation of patient's snoring on a visual analog scale (scale of 0-10, with 0 indicating no snoring and 10 indicating the bed partner to leave the room or sleep separately, as assessed by the bed partner). The primary outcomes are a 50% decrease in bed partner's snoring visual analog scale level postoperatively and an improvement of 50% or more in apnea-hypopnea index by an at least 3-month follow-up. Adverse events and patient-reported quality measures were also assessed. Forty-seven patients (36 men and 11 women; mean [SD], 47.3 [10.9] years) with a minimum 3-month follow-up and complete data were included in the analysis. None of the patients had serious perioperative or postoperative complications. Three months postoperatively, the mean (SD) scores on the Epworth Sleepiness Scale and bed partner evaluation of patient's snoring on the visual analog scale decreased

  15. Plutonium (TRU) transmutation and {sup 233}U production by single-fluid type accelerator molten-salt breeder (AMSB)

    Energy Technology Data Exchange (ETDEWEB)

    Furukaw, Kazuo [Tokai Univ., Kanagawa (Japan); Kato, Yoshio [Japan Atom. Ene. Res. Inst., Ibaraki (Japan); Chigrinov, Sergey E. [Academy of Science, Minsk (Belarus)

    1995-10-01

    For practical/industrial disposition of Pu(TRU) by accelerator facility, not only physical soundness and safety but also the following technological rationality should be required: (1) few R&D items including radiation damage, heat removal and material compatibility; (2) few operation/maintenance/processing works: (3) few reproduction of radioactivity; (4) effective energy production in parallel. This will be achieved by the new modification of Th-fertilizing Single-Fluid type Accelerator Molten-Salt Breeder (AMSB), by which a global nuclear energy strategy for next century might be prepared.

  16. Performance Evaluation of Low/Zero Voltage Ride-Through Operations for Single-Stage Single-Phase Photovoltaic Inverters

    DEFF Research Database (Denmark)

    Zhang, Zhen; Yang, Yongheng; Blaabjerg, Frede

    2017-01-01

    With the fast development of distributed power generations, stability and security have attracted extensive attention in the recent years. As a representative of clean energies, Photovoltaic (PV) systems have been installed extensively worldwide. This drives grid-connected requirements to be cont......With the fast development of distributed power generations, stability and security have attracted extensive attention in the recent years. As a representative of clean energies, Photovoltaic (PV) systems have been installed extensively worldwide. This drives grid-connected requirements......-connected single-stage single-phase PV systems in the case of Low/Zero Voltage Ride-Through (LVRT/ZVRT) operation. A comparative analysis of the two LVRT/ZVRT control methods for PV systems is presented. Simulation results are presented, which verifies that the LVRT/ZVRT methods can help the PV systems...... to temporarily ride-through the grid low-/zero-voltage faults. The power phase-angle control method has a better dynamic response....

  17. The Lifetime Estimate for ACSR Single-Stage Splice Connector Operating at Higher Temperatures

    International Nuclear Information System (INIS)

    Wang, Jy-An John; Graziano, Joe; Chan, John

    2011-01-01

    This paper is the continuation of Part I effort to develop a protocol of integrating analytical and experimental approaches to evaluate the integrity of a full tension single-stage splice connector (SSC) assembly during service at high operating temperature.1The Part II efforts are mainly focused on the thermal mechanical testing, thermal-cycling simulation and its impact on the effective lifetime of the SSC system. The investigation indicates that thermal cycling temperature and frequency, conductor cable tension loading, and the compressive residual stress field within a SSC system have significant impact on the SSC integrity and the associated effective lifetime.

  18. Fault Diagnosis for Engine Based on Single-Stage Extreme Learning Machine

    Directory of Open Access Journals (Sweden)

    Fei Gao

    2016-01-01

    Full Text Available Single-Stage Extreme Learning Machine (SS-ELM is presented to dispose of the mechanical fault diagnosis in this paper. Based on it, the traditional mapping type of extreme learning machine (ELM has been changed and the eigenvectors extracted from signal processing methods are directly regarded as outputs of the network’s hidden layer. Then the uncertainty that training data transformed from the input space to the ELM feature space with the ELM mapping and problem of the selection of the hidden nodes are avoided effectively. The experiment results of diesel engine fault diagnosis show good performance of the SS-ELM algorithm.

  19. Single-stage MPPT control realization for Aalborg inverter in photovoltaic system

    DEFF Research Database (Denmark)

    Zhang, Shuai; Wu, Weimin; Wang, Houqing

    2017-01-01

    In this paper, the single-stage Maximum Power Point Tracking (MPPT) control strategy for the Aalborg photovoltaic inverter is presented. Aalborg inverter has many advantages, such as high efficiency, wide range of input voltage, minimum voltage drop of the filtering inductors, etc. Nevertheless......, it is essentially a “half-bridge” inverter with two input sources, where one source works in MPPT mode, the other is out of control. If without the reasonable parameter design and the proper control, the bus-voltage of this inverter may change greatly, resulting in the serious power oscillation around maximum power...... that the proposed control strategy has good steady-state and dynamic performances....

  20. Simulation model of a single-stage lithium bromide-water absorption cooling unit

    Science.gov (United States)

    Miao, D.

    1978-01-01

    A computer model of a LiBr-H2O single-stage absorption machine was developed. The model, utilizing a given set of design data such as water-flow rates and inlet or outlet temperatures of these flow rates but without knowing the interior characteristics of the machine (heat transfer rates and surface areas), can be used to predict or simulate off-design performance. Results from 130 off-design cases for a given commercial machine agree with the published data within 2 percent.

  1. Promising results after single-stage reconstruction of the nipple and areola complex

    DEFF Research Database (Denmark)

    Børsen-Koch, Mikkel; Bille, Camilla; Thomsen, Jørn B

    2013-01-01

    a technique based on a local flap for reconstruction of the nipple in combination with immediate intradermal tattooing for reconstruction of the areola. Results: We reviewed the outcome of 22 cases of women who had simple single-stage reconstruction over a period of one year. We found no major and only two...... minor complications including one case of partial flap necrosis and one case of infection. Only three patients needed additional tattooing after a three-month period. The cosmetic outcome was satisfactory and none of the patients needed corrective procedures. The mean procedure time for unilateral...

  2. Vaginal Radical Trachelectomy for early stage cervical cancer. Results of the Danish National Single Center Strategy

    DEFF Research Database (Denmark)

    Hauerberg, L; Høgdall, C; Loft, A

    2015-01-01

    OBJECTIVE: To present and evaluate an unselected national single center strategy with fertility preserving trachelectomy in cervical cancer. In 2003 nationwide single-center referral of women for trachelectomies was agreed upon between all Danish departments performing cervical cancer surgery...... with the purpose of increasing volume, to increase surgical safety and facilitate follow-up. METHODS: Prospective data were recorded in the Danish Gynecological Cancer Database of all Vaginal Radical Trachelectomies (VRT) performed in Denmark between 2002 and 2013. Oncologic, fertility and obstetrical outcomes...... of 120 unselected consecutive VRTs were assessed. To obtain complete follow-up about fertility treatment, pregnancy and obstetric outcome the women filled out an electronic questionnaire. Median follow-up: 55.7 months. RESULTS: 85.8% of the patients had stage IB1 disease, 68.3% squamous cell carcinomas...

  3. Accelerated safety analyses - structural analyses Phase I - structural sensitivity evaluation of single- and double-shell waste storage tanks

    International Nuclear Information System (INIS)

    Becker, D.L.

    1994-11-01

    Accelerated Safety Analyses - Phase I (ASA-Phase I) have been conducted to assess the appropriateness of existing tank farm operational controls and/or limits as now stipulated in the Operational Safety Requirements (OSRs) and Operating Specification Documents, and to establish a technical basis for the waste tank operating safety envelope. Structural sensitivity analyses were performed to assess the response of the different waste tank configurations to variations in loading conditions, uncertainties in loading parameters, and uncertainties in material characteristics. Extensive documentation of the sensitivity analyses conducted and results obtained are provided in the detailed ASA-Phase I report, Structural Sensitivity Evaluation of Single- and Double-Shell Waste Tanks for Accelerated Safety Analysis - Phase I. This document provides a summary of the accelerated safety analyses sensitivity evaluations and the resulting findings

  4. Immediate two-stage tissue expander vs single-stage direct-to-implant breast reconstruction: two case reports of identical twins with BRCA 2 mutation

    Directory of Open Access Journals (Sweden)

    Aleš Porčnik

    2015-12-01

    Full Text Available In order to achieve the best aesthetic result after immediate implant-based breast reconstruction, all the advantages and disadvantages of two-stage tissue expander and single-stage direct-to-implant breast reconstruction should be considered. Decision about the type of implant-based reconstruction is based on the consultations outcomes after multidisciplinary team meeting of breast and reconstructive specialist, but patients own wishes should be prioritised.

  5. Design and analysis of a single stage to orbit nuclear thermal rocket reactor engine

    Energy Technology Data Exchange (ETDEWEB)

    Labib, Satira, E-mail: Satira.Labib@duke-energy.com; King, Jeffrey, E-mail: kingjc@mines.edu

    2015-06-15

    Graphical abstract: - Highlights: • Three NTR reactors are optimized for the single stage launch of 1–15 MT payloads. • The proposed rocket engines have specific impulses in excess of 700 s. • Reactivity and submersion criticality requirements are satisfied for each reactor. - Abstract: Recent advances in the development of high power density fuel materials have renewed interest in nuclear thermal rockets (NTRs) as a viable propulsion technology for future space exploration. This paper describes the design of three NTR reactor engines designed for the single stage to orbit launch of payloads from 1 to 15 metric tons. Thermal hydraulic and rocket engine analyses indicate that the proposed rocket engines are able to reach specific impulses in excess of 800 s. Neutronics analyses performed using MCNP5 demonstrate that the hot excess reactivity, shutdown margin, and submersion criticality requirements are satisfied for each NTR reactor. The reactors each consist of a 40 cm diameter core packed with hexagonal tungsten cermet fuel elements. The core is surrounded by radial and axial beryllium reflectors and eight boron carbide control drums. The 40 cm long reactor meets the submersion criticality requirements (a shutdown margin of at least $1 subcritical in all submersion scenarios) with no further modifications. The 80 and 120 cm long reactors include small amounts of gadolinium nitride as a spectral shift absorber to keep them subcritical upon submersion in seawater or wet sand following a launch abort.

  6. Heavy metal bioleaching and sludge stabilization in a single-stage reactor using indigenous acidophilic heterotrophs.

    Science.gov (United States)

    Mehrotra, Akanksha; Sreekrishnan, T R

    2017-11-01

    Simultaneous sludge digestion and metal leaching (SSDML) have been reported at mesophilic temperature. It is generally perceived that while sludge stabilization is effected by heterotrophs at neutral pH, metal bioleaching is done by acidophilic autotrophs. However, little information is available on the microbial communities involved in the process. This study carried out SSDML in a single-stage reactor using sludge indigenous microorganisms and looked at the bacterial communities responsible for the process. Volatile suspended solids were reduced by more than 40%. The concentration of zinc, copper, chromium, cadmium and nickel decreased by more than 45% in the dry sludge. Acidophilic species of Alicyclobacillus genus were the dominant heterotrophs. A few heterotrophic bacteria were detected which can oxidize iron (Alicyclobacillus ferrooxydans, Alicyclobacillus ferripilum and Ferrimicrobium acidiphilum). Acidithiobacillus ferrooxidans (autotroph) was responsible for the oxidation of both iron and sulfur which lead to a change in the pH from neutral to acidic. The presence of acidophilic heterotrophs, which can oxidize either iron or sulfur, enhanced the efficiency of SSDML process with respect to sludge stabilization and metal leaching. This study shows that it is possible to carry out the SSDML in a single-stage reactor with indigenous microorganisms.

  7. A single stage to orbit rocket with non-cryogenic propellants

    Science.gov (United States)

    Clapp, Mitchell B.; Hunter, Maxwell W.

    1993-06-01

    Different propellant combinations for single-stage-to-orbit-rocket applications were compared to oxygen/hydrogen, including nitrogen tetroxide/hydrazine, oxygen/methane, oxygen/propane, oxygen/RP-1, solid core nuclear/hydrogen, and hydrogen peroxide/JP-5. Results show that hydrogen peroxide and JP-5, which have a specific impulse of 328 s in vacuum and a density of 1,330 kg/cu m. This high-density jet fuel offers 1.79 times the payload specific energy of oxygen and hydrogen. By catalytically decomposing the hydrogen peroxide to steam and oxygen before injection into the thrust chamber, the JP-5 can be injected as a liquid into a high-temperature gas flow. This would yield superior combustion stability and permit easy throttling of the engine by adjusting the amount of JP-5 in the mixture. It is concluded that development of modern hydrogen peroxide/JP-5 engines, combined with modern structural technology, could lead to a simple, robust, and versatile single-stage-to-orbit capability.

  8. Performance evaluation of a piezoactuator-based single-stage valve system subjected to high temperature

    International Nuclear Information System (INIS)

    Jeon, Juncheol; Han, Chulhee; Ung Chung, Jye; Choi, Seung-Bok

    2015-01-01

    In this paper, a novel single-stage valve system activated by a piezostack actuator is proposed and experimentally evaluated at both room temperature (20 °C) and high temperature (100 °C) conditions. A hinge-lever displacement amplifier is adopted in the valve system to magnify the displacement generated from the piezostack actuator. After explaining the operating principle of the proposed piezostack-driven single-stage valve system, the geometric dimensions and mechanical properties of the valve components are discussed in details. An experimental apparatus is then manufactured to evaluate the performances of the valve system such as flow rate. The experimental apparatus consists of a heat chamber, which can regulate the temperature of the valve system and oil, pneumatic-hydraulic cylinders, a hydraulic circuit, a pneumatic circuit, electronic devices, an interface card, and a high voltage amplifier. The pneumatic-hydraulic cylinder transforms the pneumatic pressure into hydraulic pressure. The performances of the valve system regarding spool response, pressure drop, and flow rate are evaluated and presented. In addition, the performance of the valve system under high temperature condition is compared with that under room temperature condition. The experimental results are plotted in both frequency and time domains. (paper)

  9. Lengthening Temporalis Myoplasty for Single-Stage Smile Reconstruction in Children with Facial Paralysis.

    Science.gov (United States)

    Panossian, Andre

    2016-04-01

    Free muscle transfer for dynamic smile reanimation in facial paralysis is not always predictable with regard to cosmesis. Hospital stays range from 5 to 7 days. Prolonged operative times, longer hospital stays, and excessive cheek bulk are associated with free flap options. Lengthening temporalis myoplasty offers single-stage smile reanimation with theoretical advantages over free tissue transfer. From 2012 to 2014, 18 lengthening temporalis myoplasties were performed in 14 children for smile reconstruction. A retrospective chart review was completed for demographics, operative times, length of hospital stay, and perioperative complications. Fourteen consecutive patients with complete facial paralysis were included. Four patients underwent single-stage bilateral reconstruction, and 10 underwent unilateral procedures. Diagnoses included Möbius syndrome (n = 5), posterior cranial fossa tumors (n = 4), posttraumatic (n = 2), hemifacial microsomia (n = 1), and idiopathic (n = 2). Average patient age was 10.1 years. Average operative time was 410 minutes (499 minutes for bilateral lengthening temporalis myoplasty and 373 for unilateral lengthening temporalis myoplasty). Average length of stay was 3.3 days (4.75 days for bilateral lengthening temporalis myoplasty and 2.8 for unilateral lengthening temporalis myoplasty). Nine patients required minor revisions. Lengthening temporalis myoplasty is a safe alternative to free tissue transfer for dynamic smile reconstruction in children with facial paralysis. Limited donor-site morbidity, shorter operative times, and shorter hospital stays are some benefits over free flap options. However, revisions are required frequently secondary to tendon avulsions and adhesions. Therapeutic, IV.

  10. Shape Optimization of the Assisted Bi-directional Glenn surgery for stage-1 single ventricle palliation

    Science.gov (United States)

    Verma, Aekaansh; Shang, Jessica; Esmaily-Moghadam, Mahdi; Wong, Kwai; Marsden, Alison

    2016-11-01

    Babies born with a single functional ventricle typically undergo three open-heart surgeries starting as neonates. The first of these stages (BT shunt or Norwood) has the highest mortality rates of the three, approaching 30%. Proceeding directly to a stage-2 Glenn surgery has historically demonstrated inadequate pulmonary flow (PF) & high mortality. Recently, the Assisted Bi-directional Glenn (ABG) was proposed as a promising means to achieve a stable physiology by assisting the PF via an 'ejector pump' from the systemic circulation. We present preliminary parametrization and optimization results for the ABG geometry, with the goal of increasing PF. To limit excessive pressure increases in the Superior Vena Cava (SVC), the SVC pressure is included as a constraint. We use 3-D finite element flow simulations coupled with a single ventricle lumped parameter network to evaluate PF & the pressure constraint. We employ a derivative free optimization method- the Surrogate Management Framework, in conjunction with the OpenDIEL framework to simulate multiple simultaneous evaluations. Results show that nozzle diameter is the most important design parameter affecting ABG performance. The application of these results to patient specific situations will be discussed. This work was supported by an NSF CAREER award (OCI1150184) and by the XSEDE National Computing Resource.

  11. Hearing rehabilitation with single-stage bilateral vibroplasty in a child with Franceschetti syndrome.

    Science.gov (United States)

    Sargsyan, Sona; Rahne, Torsten; Kösling, Sabrina; Eichler, Gerburg; Plontke, Stefan K

    2014-05-01

    Hearing is of utmost importance for normal speech and social development. Even children who have mild or unilateral permanent hearing loss may experience difficulties with understanding speech, as well as problems with educational and psycho-social development. The increasing advantages of middle-ear implant technologies are opening new perspectives for restoring hearing. Active middle-ear implants can be used in children and adolescents with hearing loss. In addition to the well-documented results for improving speech intelligibility and quality of hearing in sensorineural hearing loss active middle-ear implants are now successfully used in patients with conductive and mixed hearing loss. In this article we present a case of successful, single-stage vibroplasty, on the right side with the fixation of the FMT on the stapes and PORP CLiP vibroplasty on the left side in a 6-year-old girl with bilateral mixed hearing loss and multiple dyslalia associated with Franceschetti syndrome (mandibulofacial dysostosis). CT revealed bilateral middle-ear malformations as well as an atretic right and stenotic left external auditory canal. Due to craniofacial dysmorphia airway and (post)operative, management is significantly more difficult in patients with a Franceschetti syndrome which in this case favoured a single-stage bilateral procedure. No intra- or postoperative surgical complications were reported. The middle-ear implants were activated 4 weeks after surgery. In the audiological examination 6 months after surgery, the child showed 100% speech intelligibility with activated implants on each side.

  12. In-situ sludge pretreatment in a single-stage anaerobic digester.

    Science.gov (United States)

    Chen, Yun; Xiao, Keke; Jiang, Xie; Shen, Nan; Zeng, Raymond J; Zhou, Yan

    2017-08-01

    This study aimed to develop an in-situ sludge pretreatment method by increasing the temperature from thermophilic to extreme thermophilic condition in a single-stage anaerobic digester. The results revealed that a stable performance was obtained within the temperature range of 55-65°C, and the maximum methane yield of 208.51±13.66mL/g VS was obtained at 65°C. Moreover, the maximum extent of hydrolysis (33%) and acidification (27.1%) was also observed at 65°C. However, further increase of temperature to 70°C did not improve the organic conversion efficiency. Microbial community analysis revealed that Coprothermobacter, highly related to acetate oxidisers, appeared to be the abundant bacterial group at higher temperature. A progressive shift in methanogenic members from Methanosarcina to Methanothermobacter was observed upon increasing the temperature. This work demonstrated single-stage sludge digestion system can be successfully established at high temperature (65°C) with stable performance, which can eliminate the need of conventional thermophilic pretreatment step. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Clinical staging and survival in refractory celiac disease: a single center experience.

    Science.gov (United States)

    Rubio-Tapia, Alberto; Kelly, Darlene G; Lahr, Brian D; Dogan, Ahmet; Wu, Tsung-Teh; Murray, Joseph A

    2009-01-01

    Refractory celiac disease (RCD) occurs when both symptoms and intestinal damage persist or recur despite strict adherence to a gluten-free diet. In RCD, the immunophenotype of intraepithelial lymphocytes may be normal and polyclonal (RCD I) or abnormal and monoclonal (RCD II). The aim is to describe the clinical characteristics, treatment, and long-term outcome in a large single-center cohort of patients with RCD. We compared the clinical characteristics and outcome in 57 patients with RCD: 42 with RCD I and 15 with RCD II. Fifteen of 57 patients died during follow-up (n=8 with RCD I and n=7 with RCD II), each within the first 2 years after RCD diagnosis. The overall 5-year cumulative survival is 70%, 80%, and 45% for the entire cohort, RCD I, and RCD II, respectively. The refractory state itself and enteropathy-associated T-cell lymphoma (EATL) were the most common causes of death, respectively. A new staging system is proposed based on the cumulative effect of 5 prognostic factors investigated at the time of the refractory state diagnosis: for patients in stages I, II, and III, the 5-year cumulative survival rate was 96%, 71%, and 19%, respectively (PRCD is associated with high mortality with RCD II having an especially poor prognosis because of the development of EATL. A new staging model is proposed that may improve the precision of prognosis in patients with RCD.

  14. Temperature control system for the study of single event effects in integrated circuits using a cyclotron accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Bakerenkov, A.S., E-mail: as_bakerenkov@list.ru [National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), Moscow (Russian Federation); Belyakov, V.V. [National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), Moscow (Russian Federation); Kozyukov, A.E. [Joint-Stock Company Institute of Space Device Engineering (JSC ISDE), Moscow (Russian Federation); Pershenkov, V.S.; Solomatin, A.V.; Shurenkov, V.V. [National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), Moscow (Russian Federation)

    2015-02-11

    The temperature control system for the study of single event disruptions produced by hard ion impacts in integrated circuits is described. Heating and cooling of the irradiated device are achieved using thermoelectric modules (Peltier modules). The thermodynamic performance of the system is estimated. The technique for the numerical estimation of the main parameters of the temperature control system for cooling and heating is considered. The results of a test of the system in a vacuum cell of an accelerator are presented.

  15. Single- or two-stage revision for infected total hip arthroplasty? A systematic review of the literature.

    Science.gov (United States)

    Leonard, Hugh A C; Liddle, Alexander D; Burke, Orlaith; Murray, David W; Pandit, Hemant

    2014-03-01

    The best approach for surgical treatment of an infected THA remains controversial. Two-stage revision is believed to result in lower reinfection rates but may result in significant functional impairment. Some authors now suggest that single-stage revision may provide comparable results in terms of infection eradication while providing superior functional outcomes. We performed a systematic review to determine whether single- or two-stage revision for an infected THA provides lower reinfection rates and higher functional outcome scores. We conducted a comprehensive search of PubMed and Embase, using the search string [Infection AND ("total hip replacement" OR "total hip arthroplasty") AND revision]. All studies comparing reinfection rates or functional scores for single- and two-stage revision were retrieved and reviewed. A systematic review was performed according to the PRISMA checklist. The initial search retrieved 1128 studies. Following strict exclusion criteria, we identified nine comparative studies comparing reinfection rates (all nine studies) or functional scores (four studies) between single- and two-stage revisions. The overall quality of studies was poor with no randomized studies being identified. Groups often varied in their baseline characteristics. There was no consensus among the studies regarding the relative incidence of reinfection between the two procedures. There was a trend toward better functional outcomes in single-stage surgery, but this reached significance in only one study. In appropriate patients, single-stage revision appears to be associated with similar reinfection rates when compared with two-stage revision with superior functional outcomes. This concurs with earlier studies, but given the methodologic quality of the included studies, these findings should be treated with caution. High-quality randomized studies are needed to compare the two approaches to confirm these findings, and, if appropriate, to determine which patients are

  16. Comparison of feature and classifier algorithms for online automatic sleep staging based on a single EEG signal

    NARCIS (Netherlands)

    Radha, Mustafa; Garcia Molina, Gary; Poel, Mannes; Tononi, Giulio

    Automatic sleep staging on an online basis has recently emerged as a research topic motivated by fundamental sleep research. The aim of this paper is to find optimal signal processing methods and machine learning algorithms to achieve online sleep staging on the basis of a single EEG signal. The

  17. Magnesium isotope evidence for single stage formation of CB chondrules by colliding planetesimals

    DEFF Research Database (Denmark)

    Olsen, Mia Bjørg Stolberg; Schiller, Martin; Krot, Alexander N.

    2013-01-01

    Chondrules are igneous spherical objects preserved in chondritic meteorites and believed to have formed during transient heating events in the solar protoplanetary disk. Chondrules present in the metal-rich CB chondrites show unusual chemical and petrologic features not observed in other chondrite...... groups, implying a markedly distinct formation mechanism. Here, we report high-precision Mg-isotope data for 10 skeletal olivine chondrules from the Hammadah al Hamra 237 (HH237) chondrite to probe the formation history of CB chondrules. The Al/Mg ratios of individual chondrules are positively correlated...... to their stable Mg-isotope composition (μMg), indicating that the correlated variability was imparted by a volatility-controlled process (evaporation/condensation). The mass-independent Mg composition (μMg*) of chondrules is consistent with single stage formation from an initially homogeneous magnesium reservoir...

  18. Aeration Strategies To Mitigate Nitrous Oxide Emissions from Single-Stage Nitritation/Anammox Reactors

    DEFF Research Database (Denmark)

    Domingo Felez, Carlos; Mutlu, A. Gizem; Jensen, Marlene Mark

    2014-01-01

    Autotrophic nitrogen removal is regarded as a resource efficient process to manage nitrogen-rich residual streams. However, nitrous oxide emissions of these processes are poorly documented and strategies to mitigate emissions unknown. In this study, two sequencing batch reactors performing single......-stage nitritation/anammox were operated under different aeration strategies, gradually adjusted over six months. At constant but limiting oxygen loading, synthetic reject water was fed (0.75g-N/L.d) and high nitrogen removal efficiencies (83 +/- 5 and 88 +/- 2%) obtained. Dynamics of liquid phase nitrous (N2O......) and nitric oxide (NO) concentrations were monitored and N2O emissions calculated. Significant decreases in N2O emissions were obtained when the frequency of aeration was increased while maintaining a constant air flow rate (from >6 to 1.7% Delta N2O/Delta TN). However, no significant effect on the emissions...

  19. A numerical investigation on the unstable flow in a single stage of an axial compressors

    CERN Document Server

    Farhanieh, B; Ghorbanian, K

    2003-01-01

    An unsteady two-dimensional finite-volume solver was developed based on Van Leer's flux splitting algorithm in conjunction with sup M onotonic Upstream Scheme for Conservation Laws sup l imiters to improve the order of accuracy and the two-layer Baldwin-Lomax turbulence model was also implemented. Two test cases were prepared to validate the solver. The computed results were compared with the experimental data and a good agreement validated the solver. Finally, the solver was used for the flow through a multi-blade stage of an axial compressor in its off-design condition. The computed results showed a rotating stall-like instability with a periodic behavior. To investigate the flow properties during the instability condition, the flow pattern, vortex properties and the axial velocity were studied. It was concluded that the instability vortices in the multi-blade cascade do not have the same generation history of the separated vortices over a single body.

  20. Clean-chemistry synthesis of 2-tetralones in a single-stage acylation-cycloalkylation process.

    Science.gov (United States)

    Gray, A D; Smyth, T P

    2001-10-19

    The preparation of substituted-2-tetralones by direct reaction of a 1-alkene with a substituted phenylacetic acid in a reaction system of trifluoroacetic anhydride (TFAA) and phosphoric acid is described. This single-stage process involves in situ formation of a mixed anhydride of the phenylacetic acid and acylation of the alkene by this species followed by cycloalkylation of the aromatic ring. This is a cleaner approach to the synthesis of 2-tetralones compared to Friedel-Crafts aliphatic acylation-cycloalkylation in that use of thionyl chloride, aluminum trichloride, and a chlorinated hydrocarbon solvent is eliminated. In addition, the atom efficiency is augmented by recovery of the spent TFAA as trifluoroacetic acid (TFA) and conversion of this back to TFAA by dehydration.

  1. Isolated EWiRaC: A New Low-Stress Single-Stage Isolated PFC Converter

    DEFF Research Database (Denmark)

    Schneider, Henrik; Bergendorff, Stefan Pihl; Petersen, Lars

    2007-01-01

    A new PFC-family of Efficient Wide Range Converters named EWiRaC was recently introduced. EWiRaC has a major advantage in terms of efficiency at low-line and handles challenges like inrush current limiting as an integrated part of the conversion scheme. The main objective of this paper is to inve......A new PFC-family of Efficient Wide Range Converters named EWiRaC was recently introduced. EWiRaC has a major advantage in terms of efficiency at low-line and handles challenges like inrush current limiting as an integrated part of the conversion scheme. The main objective of this paper...... is to investigate the performance of an isolated EWiRaC (I-EWiRaC) in a single-stage PFC configuration....

  2. Identification of Dewetting Stages and Preparation of Single Chain Gold Nanoparticle Rings by Colloidal Lithography.

    Science.gov (United States)

    Nagy, Norbert; Zámbó, Dániel; Pothorszky, Szilárd; Gergely-Fülöp, Eszter; Deák, András

    2016-02-02

    Massively parallel nanoparticle assembly was carried out by means of colloidal lithographic experiments over a silicon substrate supported (sub)microparticle Langmuir-Blodgett monolayer, using high purity aqueous solution of PEGylated gold nanoparticles. The size of the polystyrene template particles in the monolayer was varied between 608 nm and 2.48 μm, while gold nanoparticles with diameters between 18 and 65 nm were used. Thanks to the PEGylation of the gold nanoparticles, they could be used as tracer objects to follow the drying process. In this way, different dewetting stages could be identified in the confined space between and underneath the template polystyrene spheres. Depending on the concentration of the nanoparticles, the presented approach allows the preparation of single-particle width necklace structures composed of gold particles. At the same time, the high purity of the substrate as well as of the evolved particle rings is preserved and unwanted particle deposition on the substrate surface is minimized.

  3. High efficiency 40 K single-stage Stirling-type pulse tube cryocooler

    Science.gov (United States)

    Wu, X. L.; Chen, L. B.; Pan, C. Z.; Cui, C.; Wang, J. J.; Zhou, Y.

    2017-12-01

    A high efficiency single-stage Stirling-type coaxial pulse tube cryocooler (SPTC) operating at around 40 K has been designed, built and tested. The double-inlet and the inertance tubes together with the gas reservoir were adopted as the phase shifters. Under the conditions of 2.5 MPa charging pressure and 30 Hz operating frequency, the prototype has achieved a no-load temperature of 23.8 K with 330 W of electric input power at a rejection temperature of 279 K. When the input power increases to 400 W, it can achieve a cooling capacity of 4.7 W/40 K while rejecting heat at 279 K yielding an efficiency of 7.02% relative to Carnot. It achieves a cooling capacity of 5 W/40 K with an input power of 450 W. It takes 10 minutes for the SPTC to cool to its no-load temperature of 40 K from 295 K.

  4. Self-Excited Single-Stage Power Factor Correction Driving Circuit for LED Lighting

    Directory of Open Access Journals (Sweden)

    Yong-Nong Chang

    2014-01-01

    Full Text Available This pa\tper proposes a self-excited single-stage high power factor LED lighting driving circuit. Being featured with power factor correction capability without needing any control devices, the proposed circuit structure is with low cost and suitable for commercial production. The power factor correction function is accomplished by using inductor in combination with a half-bridge quasi resonant converter to achieve active switching and yield out voltage regulation according to load requirement. Furthermore, the zero-voltage switching in the half-bridge converter can be attained to promote the overall performance efficiency of the proposed circuit. Finally, the validity and production availability of the proposed circuit will be verified as well.

  5. Detection of Brucella melitensis and Brucella abortus strains using a single-stage PCR method

    Directory of Open Access Journals (Sweden)

    Alamian, S.

    2015-04-01

    Full Text Available Brucella melitensis and Brucella abortus are of the most important causes of brucellosis, an infectious disease which is transmitted either directly or indirectly including consuming unpasteurized dairy products. Both strains are considered endemic in Iran. Common diagnostic methods such as bacteriologic cultures are difficult and time consuming regarding the bacteria. The aim of this study was to suggest a single-stage PCR method using a pair of primers to detect both B. melitensis and B. abortus. The primers were named UF1 and UR1 and the results showed that the final size of PCR products were 84 bp and 99 bp for B. melitensis and B. abortus, respectively. Therefore the method could be useful for rapid detection of B. melitensis and B. abortus simultaneously.

  6. Single stage to orbit mass budgets derived from propellant density and specific impulse

    Energy Technology Data Exchange (ETDEWEB)

    Whitehead, J.C.

    1996-06-06

    The trade between specific impulse (Isp) and density is examined in view of Single Stage To Orbit (SSTO) requirements. Mass allocations for vehicle hardware are derived from these two properties, for several propellant combinations and a dual-fuel case. This comparative analysis, based on flight-proven hardware, indicates that the higher density of several alternative propellants compensates for reduced Isp, when compared with cryogenic oxygen and hydrogen. Approximately half the orbiting mass of a rocket- propelled SSTO vehicle must be allocated to propulsion hardware and residuals. Using hydrogen as the only fuel requires a slightly greater fraction of orbiting mass for propulsion, because hydrogen engines and tanks are heavier than those for denser fuels. The advantage of burning both a dense fuel and hydrogen in succession depends strongly on tripropellant engine weight. The implications of the calculations for SSTO vehicle design are discussed, especially with regard to the necessity to minimize non-tankage structure.

  7. Single-stage management with combined tri-endoscopic approach for concomitant cholecystolithiasis and choledocholithiasis.

    Science.gov (United States)

    Lv, Fujing; Zhang, Shutian; Ji, Ming; Wang, Yongjun; Li, Peng; Han, Wei

    2016-12-01

    The aim of this study was to investigate the value of a single stage with combined tri-endoscopic (duodenoscopy, laparoscopy and choledochoscopy) approach for patients with concomitant cholecystolithiasis and choledocholithiasis. Fifty-three patients with combined gallbladder stones and common bile duct stones from February 2014 to April 2015 were randomized assigned to two groups: 29 patients underwent single-stage surgery with combined duodenoscope, laparoscope and choledochoscope (combined tri-endoscopic group), and 29 patients underwent endoscopic sphincterotomy to remove common bile duct stones followed by laparoscopic cholecystectomy several days later (control group). The success rate of complete stone removal, procedure-related complication, hospital stay and the cost of hospitalization were compared between the two groups. Altogether, 53 patients (29 patients in combined tri-endoscopic group and 24 patients in control group) successfully underwent the surgery and ERCP procedure. Three patients in the control group developed post-ERCP pancreatitis. One case of bile leaking and one case of residual stone were noted in the combined tri-endoscopic group. There were no significant differences between the two groups with regard to both complete stone removal [96.6 % (28/29) vs. 100 % (24/24)] and procedure-related complication rate [3.4 % (1/29) vs. 12.5 % (3/24)] (p > 0.05). No open surgery was required in either group. There were significant differences between the two groups with regard to hospital stay (6.72 ± 1.3 days vs. 10.91 ± 1.6 days, p choledocholithiasis was just as safe and successful as the control group. In addition, it resulted in a shorter hospital stay and less cost.

  8. Outcome of single stage vertebral column resection in treatment of kyphotic deformity.

    Science.gov (United States)

    Arif, Mohammad; Satar, Abdul; Saeed, Muhammad; Wazir, Zahid; Inam, Mohammad

    2014-12-01

    To find the frequency of deformity correction, functional outcome and complications of single-stage vertebral column resection in patients with kyphotic deformity. The prospective case series was conducted at Hayatabad Medical Complex, Peshawar, and Aman Hospital, Peshawar, from January 2012 to December 2013, and comprised all patients who underwent single-stage posterior vertebral column resection. Only patients with severe rigid sharp deformity of different aetiology that required more than 40 degree correction and who had at least 3-month follow-up were included. Data was processed using SPSS 16. Of the total 18 patients, 11(61.1%) were male and 7(38.9%) were female, with an overall mean age of 28.7±13.6 years (range: 12-60 years). Among them, 8(44.4%) patients had congenital kyphosis, 5(27.8%) had posttraumatic origin, 4(22.2%) had post-tuberculous deformity, while 1(5.6%) had iatrogenic kyphosis. The apex of the deformity was in thoracic spine in 12(66.7%) patients, while in 6(33.3%) patients it was in the lumbar spine. The average pre- and post-operative Cobb's angle was 66.2±18.9 degrees and 18.8±12.8 degrees respectively. Mean correction of deformities was 47.3±13.3 degrees. The mean correction achieved in percentage terms was 73.5±8.6 per cent (range: 56-87%). There were no patients with post-operative deterioration of neurological status. Two (11%) patients underwent re-exploration of the wounds with wash and cultures due to wound discharge. Posterior vertebral column resection was found to be a very effective method of correction of severe kyphotic deformities in expert hands with acceptable morbidity.

  9. Metoidioplasty as a single stage sex reassignment surgery in female transsexuals: Belgrade experience.

    Science.gov (United States)

    Djordjevic, Miroslav L; Stanojevic, Dusan; Bizic, Marta; Kojovic, Vladimir; Majstorovic, Marko; Vujovic, Svetlana; Milosevic, Alexandar; Korac, Gradimir; Perovic, Sava V

    2009-05-01

    Metoidioplasty represents one of the variants of phalloplasty in female transsexuals. Its main characteristic is that it is a one-stage procedure. It involves lengthening and straightening of hypertrophied clitoris to create a neophallus, urethral lengthening to enable voiding while standing, and scrotal reconstruction with insertion of testicle prostheses. Our aim is to describe our technique and highlight its advantages. Between September 2002 and April 2007, 82 female transsexuals, aged 18-54 years (mean age 31) underwent one-stage metoidioplasty. Clitoris is lengthened and straightened by division of clitoral ligaments and short urethral plate. Urethroplasty is done with combined buccal mucosa graft and genital skin flaps. Scrotum is created from labia majora in which two testicle prostheses are inserted. Simultaneously, female genitalia are removed. Patients' personal satisfaction about sensitivity and length of neophallus, possibility to void in standing position, real length of reconstructed urethra as well as complication rate comparing to other published data. The median follow-up was 32 months (range 14-69). The mean neophallic length was 5.7 cm (range 4-10). Voiding in standing position was reported in all patients, while dribbling and spraying were noticed in 23 cases and solved spontaneously. There were two urethral strictures and seven fistulas that required secondary minor revision. All patients reported preserved sensation and normal postoperative erection. Testicle prostheses rejection was not observed in any of the patients. Metoidioplasty is a single-stage and time-saving procedure. It could be an alternative to total phalloplasty in female transsexuals who do not wish to have sexual intercourse. Also, it represents a first step in cases where additional augmentation phalloplasty is required.

  10. Single-Mode Deceleration Stage Rayleigh-Taylor Instability Growth in Cylindrical Implosions

    Science.gov (United States)

    Sauppe, J. P.; Palaniyappan, S.; Bradley, P. A.; Batha, S. H.; Loomis, E. N.; Kline, J. L.; Srinivasan, B.; Bose, A.; Malka, E.; Shvarts, D.

    2017-10-01

    We present design calculations demonstrating the feasibility of measuring single-mode deceleration stage Rayleigh-Taylor instability (RTI) growth at a factor of four convergence. RTI growth rates are modified as a result of convergence [Bell LA-1321, 1951], and cylindrical targets are considered here, as they allow direct diagnostic access along the interface. The 2D computations, performed with the radiation-hydrodynamics code xRAGE [Gittings et al., CSD 2008] utilizing a new laser ray-tracing package, predict growth factors of 6 to 10 for mode 10 and 4 to 6 for mode 4, both of high interest in evaluating inertial confinement fusion capsule degradation mechanisms [Bose et al., this conference]. These results compare favorably to a linear theory [Epstein, PoP 2004] and to a buoyancy-drag model [Srebro et al., LPB 2003], which accounts for the linear and non-linear stages. Synthetic radiographs, produced by combining 2D computations of axial and transverse cross-sections, indicate this growth will be observable, and these will be compared to experimental data obtained at the OMEGA laser facility. Work performed by Los Alamos National Laboratory under contract DE-AC52-06NA25396 for the National Nuclear Security Administration of the U.S. Department of Energy. (LA-UR-17-25608).

  11. Single-Stage Step up/down Driver for Permanent-Magnet Synchronous Machines

    Science.gov (United States)

    Chen, T. R.; Juan, Y. L.; Huang, C. Y.; Kuo, C. T.

    2017-11-01

    The two-stage circuit composed of a step up/down dc converter and a three-phase voltage source inverter is usually adopted as the electric vehicle’s motor driver. The conventional topology is more complicated. Additional power loss resulted from twice power conversion would also cause lower efficiency. A single-stage step up/down Permanent-Magnet Synchronous Motor driver for Brushless DC (BLDC) Motor is proposed in this study. The number components and circuit complexity are reduced. The low frequency six-step square-wave control is used to reduce the switching losses. In the proposed topology, only one active switch is gated with a high frequency PWM signal for adjusting the rotation speed. The rotor position signals are fed back to calculate the motor speed for digital close-loop control in a MCU. A 600W prototype circuit is constructed to drive a BLDC motor with rated speed 3000 rpm, and can control the speed of six sections.

  12. Superconductivity and future accelerators

    International Nuclear Information System (INIS)

    Danby, G.T.; Jackson, J.W.

    1963-01-01

    For 50 years particle accelerators employing accelerating cavities and deflecting magnets have been developed at a prodigious rate. New accelerator concepts and hardware ensembles have yielded great improvements in performance and GeV/$. The great idea for collective acceleration resulting from intense auxiliary charged-particle beams or laser light may or may not be just around the corner. In its absence, superconductivity (SC) applied both to rf cavities and to magnets opened up the potential for very large accelerators without excessive energy consumption and with other economies, even with the cw operation desirable for colliding beams. HEP has aggressively pioneered this new technology: the Fermilab single ring 1 TeV accelerator - 2 TeV collider is near the testing stage. Brookhaven National Laboratory's high luminosity pp 2 ring 800 GeV CBA collider is well into construction. Other types of superconducting projects are in the planning stage with much background R and D accomplished. The next generation of hadron colliders under discussion involves perhaps a 20 TeV ring (or rings) with 40 TeV CM energy. This is a very large machine: even if the highest practical field B approx. 10T is used, the radius is 10x that of the Fermilab accelerator. An extreme effort to get maximum GeV/$ may be crucial even for serious consideration of funding

  13. Rapid near-optimal trajectory generation and guidance law development for single-stage-to-orbit airbreathing vehicles

    Science.gov (United States)

    Calise, A. J.; Flandro, G. A.; Corban, J. E.

    1990-01-01

    General problems associated with on-board trajectory optimization, propulsion system cycle selection, and with the synthesis of guidance laws were addressed for an ascent to low-earth-orbit of an air-breathing single-stage-to-orbit vehicle. The NASA Generic Hypersonic Aerodynamic Model Example and the Langley Accelerator aerodynamic sets were acquired and implemented. Work related to the development of purely analytic aerodynamic models was also performed at a low level. A generic model of a multi-mode propulsion system was developed that includes turbojet, ramjet, scramjet, and rocket engine cycles. Provisions were made in the dynamic model for a component of thrust normal to the flight path. Computational results, which characterize the nonlinear sensitivity of scramjet performance to changes in vehicle angle of attack, were obtained and incorporated into the engine model. Additional trajectory constraints were introduced: maximum dynamic pressure; maximum aerodynamic heating rate per unit area; angle of attack and lift limits; and limits on acceleration both along and normal to the flight path. The remainder of the effort focused on required modifications to a previously derived algorithm when the model complexity cited above was added. In particular, analytic switching conditions were derived which, under appropriate assumptions, govern optimal transition from one propulsion mode to another for two cases: the case in which engine cycle operations can overlap, and the case in which engine cycle operations are mutually exclusive. The resulting guidance algorithm was implemented in software and exercised extensively. It was found that the approximations associated with the assumed time scale separation employed in this work are reasonable except over the Mach range from roughly 5 to 8. This phenomenon is due to the very large thrust capability of scramjets in this Mach regime when sized to meet the requirement for ascent to orbit. By accounting for flight path

  14. Single stage: dorsolateral onlay buccal mucosal urethroplasty for long anterior urethral strictures using perineal route

    Directory of Open Access Journals (Sweden)

    Vikram Prabha

    2016-06-01

    Full Text Available ABSTRACT Objective To assess the outcome of single stage dorsolateral onlay buccal mucosal urethroplasty for long anterior urethral strictures (>4cm long using a perineal incision. Materials and Methods From August 2010 to August 2013, 20 patients underwent BMG urethroplasty. The cause of stricture was Lichen sclerosis in 12 cases (60%, Instrumentation in 5 cases (25%, and unknown in 3 cases (15%. Strictures were approached through a perineal skin incision and penis was invaginated into it to access the entire urethra. All the grafts were placed dorsolaterally, preserving the bulbospongiosus muscle, central tendon of perineum and one-sided attachement of corpus spongiosum. Procedure was considered to be failure if the patient required instrumentation postoperatively. Results Mean stricture length was 8.5cm (range 4 to 12cm. Mean follow-up was 22.7 months (range 12 to 36 months. Overall success rate was 85%. There were 3 failures (meatal stenosis in 1, proximal stricture in 1 and whole length recurrent stricture in 1. Other complications included wound infection, urethrocutaneous fistula, brownish discharge per urethra and scrotal oedema. Conclusion Dorsolateral buccal mucosal urethroplasty for long anterior urethral strictures using a single perineal incision is simple, safe and easily reproducible by urologists with a good outcome.

  15. Ion sources for electrostatic accelerators

    International Nuclear Information System (INIS)

    Hellborg, R.

    1998-01-01

    Maybe the most important part of an electrostatic accelerator system, and also often the most tricky part is the ion source. There has been a rapid growth in activity in ion-source research and development during the last two to three decades. Some of these developments have also been of benefit to electrostatic accelerator users. In this report some of the different types of ion sources used in electrostatic accelerators are described. The list is not complete but more an overview of some of the more commonly used sources. The description is divided into two groups; positive ion sources for single stage electrostatic accelerators and negative ion sources for two stages (i.e. tandem) accelerators

  16. Bunch-shape monitor for a picosecond single-bunch beam of a 35 MeV electron linear accelerator

    International Nuclear Information System (INIS)

    Hosono, Yoneichi; Nakazawa, Masaharu; Iguchi, Tetsuo

    1995-01-01

    A non-interactive-type bunch-shape and beam intensity monitor for a 35 MeV electron linear accelerator (linac) has been developed. The monitor consists of an electric SMA-type connector and an Al pipe of 50 mm inner diameter. Test measurements of the present monitor have been made under the conditions of the accelerated charges of lower than 27 nC/pulse and the pulse width ranging from 6 to 30 ps (Full Width at Half Maximum). The results show that the present monitor is applicable to bunch-shape measurement of the picosecond single-bunch beam. The monitor output is also found to be proportional to the beam intensity of more than 0.05 nC/pulse. (author)

  17. Clinical application of Half Fourier Acquisition Single Shot Turbo Spin Echo (HASTE) imaging accelerated by simultaneous multi-slice acquisition.

    Science.gov (United States)

    Schulz, Jenni; P Marques, José; Ter Telgte, Annemieke; van Dorst, Anouk; de Leeuw, Frank-Erik; Meijer, Frederick J A; Norris, David G

    2018-01-01

    As a single-shot sequence with a long train of refocusing pulses, Half-Fourier Acquisition Single-Shot Turbo-Spin-Echo (HASTE) suffers from high power deposition limiting use at high resolutions and high field strengths, particularly if combined with acceleration techniques such as simultaneous multi-slice (SMS) imaging. Using a combination of multiband (MB)-excitation and PINS-refocusing pulses will effectively accelerate the acquisition time while staying within the SAR limitations. In particular, uncooperative and young patients will profit from the speed of the MB-PINS HASTE sequence, as clinical diagnosis can be possible without sedation. Materials and MethodsMB-excitation and PINS-refocusing pulses were incorporated into a HASTE-sequence with blipped CAIPIRINHA and TRAPS including an internal FLASH reference scan for online reconstruction. Whole brain MB-PINS HASTE data were acquired on a Siemens 3T-Prisma system from 10 individuals and compared to a clinical HASTE protocol. ResultsThe proposed MB-PINS HASTE protocol accelerates the acquisition by about a factor 2 compared to the clinical HASTE. The diagnostic image quality proved to be comparable for both sequences for the evaluation of the overall aspect of the brain, the detection of white matter changes and areas of tissue loss, and for the evaluation of the CSF spaces although artifacts were more frequently encountered with MB-PINS HASTE. ConclusionsMB-PINS HASTE enables acquisition of slice accelerated highly T2-weighted images and provides good diagnostic image quality while reducing acquisition time. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Calculations following voltage breakdown in a single-ended Van de Graaff with an accelerator tube

    International Nuclear Information System (INIS)

    Staniforth, J.A.

    1979-01-01

    Calculation of voltages and voltage gradients in the terminal, along the insulating column and the accelerating tube are described for various breakdown positions. The method uses a number of inverted-L network sections to represent the machine assuming that the tube is coupled to the column. Various forms of coupling are examined. The calculations use an iterative computer program which calculates the voltages and currents in the networks at successive small time intervals. (author)

  19. Feasibility of a single-stage tracheostomy decannulation protocol with endoscopy in adult patients.

    Science.gov (United States)

    Cohen, Oded; Tzelnick, Sharon; Lahav, Yonatan; Stavi, Dekel; Shoffel-Havakuk, Hagit; Hain, Moshe; Halperin, Doron; Adi, Nimrod

    2016-09-01

    Gradual decrease in tube size and tube capping are considered the standard of care for tracheostomy decannulation. Both of these actions result in increased airway resistance. Immediate decannulation may offer a more tolerable approach. To assess the feasibility of immediate tracheostomy decannulation compared with the traditional decannulation methods. This study is a single institute, case-control retrospective study of patients between the years 2009 to 2014. The study group included all patients who underwent immediate decannulation, whereas the control group comprised patients who underwent traditional staged decannulation. An immediate decannulation protocol included admission to the intensive care unit, a comprehensive evaluation, decannulation, 24 hours of monitoring, and observation until discharge. Twenty-nine patients were included in the study group and 20 in the control group. No significant statistical difference was found between the two groups in the patients' medical history and tracheostomy data, except for the Acute Physiology and Chronic Health Evaluation II score and duration of the deflated cuff, which were significantly higher in the control group. A significant difference was found in the complication rate between the groups. In the staged decannulation group, four patients failed decannulation and required reinsertion of the tracheostomy cannula, whereas there were no such failures in the immediate decannulation group. Hospitalization duration after decannulation of the study group patients was significantly shorter than that of the control group. Immediate decannulation may offer a safe alternative for weaning from tracheostomy. It may also reduce the duration of the weaning process and hospitalization. 3b Laryngoscope, 126:2057-2062, 2016. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  20. Evaluation of single-stage adjustable strabismus surgery under conscious sedation

    Directory of Open Access Journals (Sweden)

    Sharma Pradeep

    2009-01-01

    Full Text Available Purpose: To evaluate the feasibility and stability of ocular alignment after single-stage adjustable strabismus surgery (SSASS performed under topical anesthesia. Materials and Methods: Forty-five patients of concomitant exodeviations were randomized into three groups of 15 cases each and were operated with three different techniques: Group I - conventional surgery, Group II - two-stage adjustable suture technique with suture adjustment performed 6h postoperatively and Group III- SSASS under topical anesthesia and intravenous conscious sedation with midazolam and fentanyl. Intraoperative suture adjustment was done by giving a cross target to the patient on the ceiling at the end of the procedure. Surgical results were compared among the three groups at three months follow-up. Intraoperative hemodynamic parameters and patients′ experience of the surgery (by questionnaire were also compared. Results: Mean preoperative deviation for distance in Groups I, II, III was -41.67 prism diopter (pd ±9.0, -38.93 pd ±11.05 and -41.87 pd ±8.91 ( P =0.6 respectively. At three months, mean correction achieved for distance was +31.87 pd ±11.71, +35.47 pd ±10.86 and +42.80 pd ±10.71 respectively which was significantly different between Group III and Group I ( P =0.03. Intraoperatively all hemodynamic parameters remained stable and comparable ( P =0. 5 in all groups. Intraoperative pain ( P < 0.001 and time taken for surgery ( P < 0.001 was more in the SSASS group. Amount of exodrift was 10-12 pd, comparable in all three groups ( P = 0.5. Conclusions: SSASS, performed under topical anesthesia, is safe and has better outcomes than conventional recession-resection surgery for concomitant exodeviation. An overcorrection of about 10-12 pd is recommended to check the exodrift and achieve stable alignment.

  1. Thrombotic complications and thromboprophylaxis across all three stages of single ventricle heart palliation.

    Science.gov (United States)

    Manlhiot, Cedric; Brandão, Leonardo R; Kwok, Judith; Kegel, Stefan; Menjak, Ines B; Carew, Caitlin L; Chan, Anthony K; Schwartz, Steven M; Sivarajan, V Ben; Caldarone, Christopher A; Van Arsdell, Glen S; McCrindle, Brian W

    2012-09-01

    To describe the incidence of thrombotic complications across all 3 stages of single ventricle palliation and the association between thromboprophylaxis use and thrombotic risk. Two separate cross-sectional studies were performed that included 195 patients born between 2003-2008 and 162 patients who underwent Fontan after 2000. The incidence of thrombotic complications was 40% and 28% after initial palliation and superior cavopulmonary connection (SCPC), respectively; 5-year freedom from thrombotic complications after Fontan was 79%. Thromboprophylaxis was initiated for 70%, 46%, and 94% of patients after initial palliation, SCPC, and Fontan, respectively. Thromboprophylaxis with enoxaparin (vs no thromboprophylaxis) was associated with a reduction in risk of thrombotic complications after initial palliation (hazard ratio [HR] 0.5, P = .05) and SCPC (HR 0.2, P = .04). Thromboprophylaxis with warfarin was associated with a reduction in thrombotic complications after Fontan (HR 0.27, P = .05 vs acetylsalicylic acid; HR 0.18, P = .02 vs no thromboprophylaxis). Thrombotic complications were associated with increased mortality after initial palliation (HR 5.5, P SCPC (HR 12.5, P < .001). Three patients experienced major bleeding complications without permanent sequelae (2 enoxaparin, 1 warfarin). Given the negative impact of thrombotic complications on survival, the low risk of serious bleeding complications, and the association between thromboprophylaxis and lowered thrombotic complication risk across all 3 palliative stages, routine use of thromboprophylaxis from the initial palliation to the early post-Fontan period in this population may be indicated. Copyright © 2012 Mosby, Inc. All rights reserved.

  2. Molecular asymmetry in the 8-cell stage Xenopus tropicalis embryo described by single blastomere transcript sequencing.

    Science.gov (United States)

    De Domenico, Elena; Owens, Nick D L; Grant, Ian M; Gomes-Faria, Rosa; Gilchrist, Michael J

    2015-12-15

    Correct development of the vertebrate body plan requires the early definition of two asymmetric, perpendicular axes. The first axis is established during oocyte maturation, and the second is established by symmetry breaking shortly after fertilization. The physical processes generating the second asymmetric, or dorsal-ventral, axis are well understood, but the specific molecular determinants, presumed to be maternal gene products, are poorly characterized. Whilst enrichment of maternal mRNAs at the animal and vegetal poles in both the oocyte and the early embryo has been studied, little is known about the distribution of maternal mRNAs along either the dorsal-ventral or left-right axes during the early cleavage stages. Here we report an unbiased analysis of the distribution of maternal mRNA on all axes of the Xenopus tropicalis 8-cell stage embryo, based on sequencing of single blastomeres whose positions within the embryo are known. Analysis of pooled data from complete sets of blastomeres from four embryos has identified 908 mRNAs enriched in either the animal or vegetal blastomeres, of which 793 are not previously reported as enriched. In contrast, we find no evidence for asymmetric distribution along either the dorsal-ventral or left-right axes. We confirm that animal pole enrichment is on average distinctly lower than vegetal pole enrichment, and that considerable variation is found between reported enrichment levels in different studies. We use publicly available data to show that there is a significant association between genes with human disease annotation and enrichment at the animal pole. Mutations in the human ortholog of the most animally enriched novel gene, Slc35d1, are causative for Schneckenbecken dysplasia, and we show that a similar phenotype is produced by depletion of the orthologous protein in Xenopus embryos. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  3. Thermodynamic simulation of condensation heat recovery characteristics of a single stage centrifugal chiller in a hotel

    International Nuclear Information System (INIS)

    Gong, Guangcai; Chen, Feihu; Su, Huan; Zhou, Jianyong

    2012-01-01

    Highlights: ► Thermodynamic model of a two-condenser condensation system has been carried out. ► Dynamic simulation method has been presented. ► COP and g of the refrigerating system is better than the single condensation system. ► The optimal parameters for the two-condenser condensation system have been studied. -- Abstract: A thermodynamic simulation study has been carried out for a single stage centrifugal chiller in this paper. The cooling capacity of the chiller unit is about 1750 kW. The chiller unit has been set and tested, and the work refrigerant is R22. A heat exchanger has been set between outlet of the compressor and the condenser for sanitary hot water supplying. Then the chiller unit is a kind of combined system that can provide sanitary hot water supplying and air conditioning simultaneously. A thermodynamic simulation model of the combined system has been established with the system simulation toolbox Simulink. Performance of the components and the combined system of the chiller unit has been studied over a wide range of operating conditions. The potential energy and fuel cost saving associated with the use of the proposed combined system for a typical hotel in south China has been estimated. It is showed that the combined system of the chiller unit is very useful in hotel buildings. And the thermodynamic simulation model of the combined system is significance for the optimization of parameters of the chiller unit such as condensation and evaporation temperature, mass flow of the sanitary hot water and size of hot water storage tank.

  4. Single-stage posterior transforaminal lumbar interbody fusion, debridement, limited decompression, 3-column reconstruction, and posterior instrumentation in surgical treatment for single-segment lumbar spinal tuberculosis.

    Science.gov (United States)

    Zeng, Hao; Wang, Xiyang; Zhang, Penghui; Peng, Wei; Liu, Zheng; Zhang, Yupeng

    2015-01-01

    The aim of this study is to determine the feasibility and efficacy of surgical management of single-segment lumbar spinal tuberculosis (TB) by using single-stage posterior transforaminal lumbar interbody fusion, debridement, limited decompression, 3-column reconstruction, and posterior instrumentation. Seventeen cases of single-segment lumbar TB were treated with single-stage posterior transforaminal lumbar interbody fusion, debridement, limited decompression, 3-column reconstruction, and posterior instrumentation. The mean follow-up was 36.9 months (range: 24-62 months). The kyphotic angle ranged from 15.2-35.1° preoperatively, with an average measurement of 27.8°. The American Spinal Injury Association (ASIA) score system was used to evaluate the neurological deficits and erythrocyte sedimentation rate (ESR) used to judge the activity of TB. Spinal TB was completely cured in all 17 patients. There was no recurrent TB infection. The postoperative kyphotic angle was 6.6-10.2°, 8.1° in average, and there was no significant loss of the correction at final follow-up. Solid fusion was achieved in all cases. Neurological condition in all patients was improved after surgery. Single-stage posterior transforaminal lumbar interbody fusion, debridement, limited decompression, 3-column reconstruction, and posterior instrumentation can be a feasible and effective method the in treatment of single-segment lumbar spinal TB.

  5. Outcomes of single-stage total arch replacement via clamshell incision

    Directory of Open Access Journals (Sweden)

    Ishizaka Toru

    2011-09-01

    Full Text Available Abstract Background Treatment of complex aortic pathologies involving the transverse arch with extensive involvement of the descending aorta remains a surgical challenge. Since clamshell incision provides superior exposure of the entire thoracic aorta, we evaluated the use of this technique for single-stage total arch replacement by arch vessel reconstruction. Methods The arch-first technique combined with clamshell incision was used in 38 cases of aneurysm and aortic disease in 2008 and 2009. Extensive total arch replacement was used with clamshell incision for reconstruction of arch vessels under deep hypothermic circulatory arrest. Results Overall 30-day mortality was 13%. The mean operating time was approximately 8 hours. Deep hypothermia resulted in mean CPB time exceeding 4.5 hours and mean duration of circulatory arrest was 25 minutes. The overall postoperative temporary and permanent neurologic dysfunction rates were 3% and 3% for elective and 3% and 0% for emergency surgery, respectively. All patients except the five who died in hospital were discharged without nursing care after an average post-operative hospital stay of 35 days. Conclusions The arch-first technique, combined with clamshell incision, provides expeditious replacement of the thoracic aorta with an acceptable duration of hypothermic circulatory arrest and minimizes the risk of retrograde atheroembolism by using antegrade perfusion.

  6. Solvent Carryover Characterization and Recovery for a 10-inch Single Stage Centrifugal Contactor

    International Nuclear Information System (INIS)

    Lentsch, R.D.; Stephens, A.B.; Leung, D.T.; Baffling, K.E.; Harmon, H.D.; Suggs, P.C.

    2006-01-01

    A test program has been performed to characterize the organic solvent carryover and recovery from centrifugal contactors in the Caustic-side Solvent Extraction (CSSX) process. CSSX is the baseline design for removing cesium from salt solutions for Department of Energy (DOE) Savannah River Site's Salt Waste Processing Facility. CSSX uses a custom solvent to extract cesium from the salt solution in a series of single stage centrifugal contactors. Meeting the Waste Acceptance Criteria at the Defense Waste Processing Facility and Saltstone, as well as plant economics, dictate that solvent loss should be kept to a minimum. Solvent droplet size distribution in the aqueous outlet streams of the CSSX contactors is of particular importance to the design of solvent recovery equipment. Because insufficient solvent droplet size data existed to form a basis for the recovery system design, DOE funded the CSSX Solvent Carryover Characterization and Recovery Test (SCCRT). This paper presents the droplet size distribution of solvent and concentration in the contactor aqueous outlet streams as a function of rotor speed, bottom plate type, and flow rate. It also presents the performance data of a prototype coalescer. (authors)

  7. Single-stage Kanban system with deterioration failures and condition-based preventive maintenance

    International Nuclear Information System (INIS)

    Xanthopoulos, A.S.; Koulouriotis, D.E.; Botsaris, P.N.

    2015-01-01

    Despite the fact that the fields of pull type production control policies and condition-based preventive maintenance have much in common contextually, they have evolved independently up to now. In this investigation, an attempt is made to bridge the gap between these two branches of knowledge by introducing the single-stage Kanban system with deterioration failures and condition-based preventive maintenance. The formalism of continuous time Markov chains is used to model the system and expressions for eight performance metrics are derived. Two important, from a managerial perspective, constrained optimization problems for the proposed model are defined where the objective is the simultaneous optimization of the Kanban policy, the preventive maintenance policy and the inspection schedule under conflicting performance criteria. Multiple instances of each optimization problem are solved by means of the augmented Lagrangian genetic algorithm. The results from the optimization trials coupled by the results from extensive numerical examples facilitate the thorough investigation of the system’s behaviour. - Highlights: • Kanban system with deterioration failures and preventive maintenance is introduced. • The system is modeled as a continuous time Markov chain. • Expressions for eight performance metrics are derived. • The behavior of the system is studied through numerical examples. • Optimization results for selected performance metrics are presented

  8. [Achieve single-stage autotrophic biological nitrogen removal process by controlling the concentration of free ammonia].

    Science.gov (United States)

    Ji, Li-Li; Yang, Zhao-Hui; Xu, Zheng-Yong; Li, Xiao-Jiang; Tang, Zhi-Gang; Deng, Jiu-Hu

    2011-01-01

    Through controlling the concentration of free ammonia in the sequencing batch reactor (SBR), the single-stage autotrophic biological nitrogen removal process was achieved, including partial nitrification and anaerobic ammonium oxidation. The experiment was completed via two steps, the enrichment of nitrite bacteria and the inoculation of the mixture of anammox biomass. The operating temperature in the SBR was (31 +/- 2) degrees C. During the step of the enrichment of nitrite bacteria, pH was about 7.8. Changes of FA concentration were achieved by controlling the concentration of influent NH4(+) -N(56-446 mg x L(-1)), in order to inhibit and eliminate the nitrate bacteria. The activity tests of the sludge, 55d after enrichment, showed strong activity of aerobic ammonium oxidation [2.91 kg x (kg x d)(-1)] and low activity of nitrite oxidation [0.03 kg x(kg x d)(-1)]. During the inoculation of the mixture of anammox biomass, changes of FA concentration were achieved by controlling the concentration of influent NH4(+) -N and pH. As the inoculation of anammox biomass, abundant of bacteria and nutrient content were into the reactor and there kept high activity of aerobic ammonium oxidation [2.83 kg x (kg x d)(-1)] and a certain activity of nitrite oxidation, at the same time, the activity of anammox and heterotrophic denitrification reached 0.65 kg x (kg x d)(-1) and 0.11 kg x (kg x d)(-1), respectively.

  9. Wind-driven SEIG supplying DC microgrid through a single-stage power converter

    Directory of Open Access Journals (Sweden)

    Vellapatchi Nayanar

    2016-09-01

    Full Text Available Nowadays, there is an increased emphasis on utilizing the renewable energy sources and selection of suitable power converters for supplying dc microgrid. Among the various renewable energy sources, wind energy stands first in terms of installed capacity. So, an attempt is made in this paper for supplying dc microgrid utilizing wind energy. A self-excited induction generator has been used in the proposed wind energy conversion system (WECS. A single-stage power converter, namely, semi-converter is connected between the SEIG and dc grid terminals for closed-loop control of the proposed system. A perturb and observe (P&O based maximum power point tracking (MPPT algorithm has been developed and implemented using a dsPIC30F4011 digital controller. In this MPPT algorithm, the firing angle of the converter is adjusted by continuously monitoring the dc grid current for a given wind velocity. For analyzing the proposed system, a MATLAB/Simulink model has been developed by selecting the various components starting from wind-turbine model to the power converter supplying dc microgrid. Successful working of the proposed WECS has also been shown through experimental results obtained on a prototype model developed in the laboratory.

  10. Orifice Mass Flow Calculation in NASA's W-8 Single Stage Axial Compressor Facility

    Science.gov (United States)

    Bozak, Richard F.

    2018-01-01

    Updates to the orifice mass flow calculation for the W-8 Single Stage Axial Compressor Facility at NASA Glenn Research Center are provided to include the effect of humidity and incorporate ISO 5167. A methodology for including the effect of humidity into the inlet orifice mass flow calculation is provided. Orifice mass flow calculations provided by ASME PTC-19.5-2004, ASME MFC-3M-2004, ASME Fluid Meters, and ISO 5167 are compared for W-8's atmospheric inlet orifice plate. Differences in expansion factor and discharge coefficient given by these standards give a variation of about +/- 75% mass flow except for a few cases. A comparison of the calculations with an inlet static pressure mass flow correlation and a fan exit mass flow integration using test data from a 2017 turbofan rotor test in W-8 show good agreement between the inlet static pressure mass flow correlation, ISO 5167, and ASME Fluid Meters. While W-8's atmospheric inlet orifice plate violates the pipe diameter limit defined by each of the standards, the ISO 5167 is chosen to be the primary orifice mass flow calculation to use in the W-8 facility.

  11. Single-stage transforaminal decompression, debridement, interbody fusion, and posterior instrumentation for lumbosacral brucellosis.

    Science.gov (United States)

    Abulizi, Yakefu; Liang, Wei-Dong; Muheremu, Aikeremujiang; Maimaiti, Maierdan; Sheng, Wei-Bin

    2017-07-14

    Spinal brucellosis is a less commonly reported infectious spinal pathology. There are few reports regarding the surgical treatment of spinal brucellosis in existing literature. This retrospective study was conducted to determine the effectiveness of single-stage transforaminal decompression, debridement, interbody fusion, and posterior instrumentation for lumbosacral spinal brucellosis. From February 2012 to April 2015, 32 consecutive patients (19 males and 13 females, mean age 53.7 ± 8.7) with lumbosacral brucellosis treated by transforaminal decompression, debridement, interbody fusion, and posterior instrumentation were enrolled. Medical records, imaging studies, laboratory data were collected and summarized. Surgical outcomes were evaluated based on visual analogue scale (VAS), Oswestry Disability Index (ODI) and Japanese Orthopaedic Association (JOA) scale. The changes in C-reactive protein (CRP) levels, erythrocyte sedimentation rate (ESR), clinical symptoms and complications were investigated. Graft fusion was evaluated using Bridwell grading criteria. The mean follow-up period was 24.9 ± 8.2 months. Back pain and radiating leg pain was relieved significantly in all patients after operation. No implant failures were observed in any patients. Wound infection was observed in two patients and sinus formation was observed in one patient. Solid bony fusion was achieved in 30 patients and the fusion rate was 93.8%. The levels of ESR and CRP were returned to normal by the end of three months' follow-up. VAS and ODI scores were significantly improved (P brucellosis.

  12. Revision Anterior Cruciate Ligament Reconstruction: Results of a Single-stage Approach Using Allograft Dowel Bone Grafting for Femoral Defects.

    Science.gov (United States)

    Werner, Brian C; Gilmore, Carl J; Hamann, Joshua C; Gaskin, Cree M; Carroll, John J; Hart, Joseph M; Miller, Mark D

    2016-08-01

    The purpose of this study was to present results of single-stage revision anterior cruciate ligament (ACL) reconstruction using an allograft bone dowel for isolated femoral bony deficiency. Sixteen patients underwent single-stage revision ACL reconstruction using an allograft bone dowel for isolated femoral bony deficiency between 2007 and 2012. Twelve patients (75%) completed study visits, which included CT scans as well as completion of validated outcomes measures. The average KT-1000 side-to-side difference was 1.0 mm ± 2.9 mm. The average International Knee Documentation Committee score was 70.2 ± 17.8, the Tegner score was 4.8 ± 2.8, and the visual analog scale pain score was 2.8 ± 2.4. An analysis of CT scans showed that all 12 dowels had excellent (>75%) incorporation. A single-stage approach for revision ACL reconstruction using allograft dowels for isolated femoral bony deficiency yields objective and subjective outcomes comparable to those reported in the literature for two-stage and other single-stage techniques, with good incorporation of the dowels. Retrospective case series, level IV.

  13. Statistical issues for design and analysis of single-arm multi-stage phase II cancer clinical trials.

    Science.gov (United States)

    Jung, Sin-Ho

    2015-05-01

    Phase II trials have been very widely conducted and published every year for cancer clinical research. In spite of the fast progress in design and analysis methods, single-arm two-stage design is still the most popular for phase II cancer clinical trials. Because of their small sample sizes, statistical methods based on large sample approximation are not appropriate for design and analysis of phase II trials. As a prospective clinical research, the analysis method of a phase II trial is predetermined at the design stage and it is analyzed during and at the end of the trial as planned by the design. The analysis method of a trial should be matched with the design method. For two-stage single arm phase II trials, Simon's method has been the standards for choosing an optimal design, but the resulting data have been analyzed and published ignoring the two-stage design aspect with small sample sizes. In this article, we review analysis methods that exactly get along with the exact two-stage design method. We also discuss some statistical methods to improve the existing design and analysis methods for single-arm two-stage phase II trials. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. On-line monitoring system development for single-phase flow accelerated corrosion

    International Nuclear Information System (INIS)

    Lee, Na Young; Lee, Seung Gi; Ryu, Kyung Ha; Hwang, Il Soon

    2007-01-01

    Aged nuclear piping has been reported to undergo corrosion-induced accelerated failures, often without giving signatures to current inspection campaigns. Therefore, we need diverse sensors which can cover a wide area in an on-line application. We suggest an integrated approach to monitor the flow accelerated corrosion (FAC) susceptible piping. Since FAC is a combined phenomenon, we need to monitor as many parameters as possible and that cover wide area, since we do not know where the FAC occurs. For this purpose, we introduce the wearing rate model which focuses on the electrochemical parameters. Using this model, we can predict the wearing rate and then compare testing results. Through analysis we identified feasibility and then developed electrochemical sensors for high temperature application; we also introduced a mechanical monitoring system which is still under development. To support the validation of the monitored results, we adopted high temperature ultrasonic transducer (UT), which shows good resolution in the testing environment. As such, all the monitored results can be compared in terms of thickness. Our validation tests demonstrated the feasibility of sensors. To support direct thickness measurement for a wide-area, the direct current potential drop (DCPD) method will be researched to integrate into the developed framework

  15. Accelerated median root prior reconstruction for pinhole single-photon emission tomography (SPET)

    Energy Technology Data Exchange (ETDEWEB)

    Sohlberg, Antti [Department of Clinical Physiology and Nuclear Medicine, Kuopio University Hospital, PO Box 1777 FIN-70211, Kuopio (Finland); Ruotsalainen, Ulla [Institute of Signal Processing, DMI, Tampere University of Technology, PO Box 553 FIN-33101, Tampere (Finland); Watabe, Hiroshi [National Cardiovascular Center Research Institute, 5-7-1 Fujisihro-dai, Suita City, Osaka 565-8565 (Japan); Iida, Hidehiro [National Cardiovascular Center Research Institute, 5-7-1 Fujisihro-dai, Suita City, Osaka 565-8565 (Japan); Kuikka, Jyrki T [Department of Clinical Physiology and Nuclear Medicine, Kuopio University Hospital, PO Box 1777 FIN-70211, Kuopio (Finland)

    2003-07-07

    Pinhole collimation can be used to improve spatial resolution in SPET. However, the resolution improvement is achieved at the cost of reduced sensitivity, which leads to projection images with poor statistics. Images reconstructed from these projections using the maximum likelihood expectation maximization (ML-EM) algorithms, which have been used to reduce the artefacts generated by the filtered backprojection (FBP) based reconstruction, suffer from noise/bias trade-off: noise contaminates the images at high iteration numbers, whereas early abortion of the algorithm produces images that are excessively smooth and biased towards the initial estimate of the algorithm. To limit the noise accumulation we propose the use of the pinhole median root prior (PH-MRP) reconstruction algorithm. MRP is a Bayesian reconstruction method that has already been used in PET imaging and shown to possess good noise reduction and edge preservation properties. In this study the PH-MRP algorithm was accelerated with the ordered subsets (OS) procedure and compared to the FBP, OS-EM and conventional Bayesian reconstruction methods in terms of noise reduction, quantitative accuracy, edge preservation and visual quality. The results showed that the accelerated PH-MRP algorithm was very robust. It provided visually pleasing images with lower noise level than the FBP or OS-EM and with smaller bias and sharper edges than the conventional Bayesian methods.

  16. Assessment of left ventricular function with single breath-hold highly accelerated cine MRI combined with guide-point modeling

    International Nuclear Information System (INIS)

    Heilmaier, Christina; Nassenstein, Kai; Nielles-Vallespin, Sonia; Zuehlsdorff, Sven; Hunold, Peter; Barkhausen, Joerg

    2010-01-01

    Purpose: To prospectively assess the performance of highly accelerated cine MRI in multi-orientations combined with a new guide-point modeling post-processing technique (GPM approach) for assessment of left ventricular (LV) function compared to the standard summation of slices method based on a stack of short axis views (SoS approach). Materials and methods: 33 consecutive patients were examined on a 1.5 T scanner with a standard steady state free precession (SSFP) sequence (TR, 3.0 ms; TE, 1.5 m; flip angle (FA), 60 o ; acceleration factor (AF), 2) analyzed with the SoS method and a highly accelerated, single breath-hold temporal parallel acquisition SSFP sequence (TR, 4.6 ms; TE, 1.1 ms; AF, 3) post-processed with the GPM method. LV function values were measured by two independent readers with different experience in cardiac MRI and compared by using the paired t-test and F-test. Inter- and intraobserver agreements were calculated using Bland-Altman-Plots. Results: Mean acquisition and post-processing time was significantly shorter with the GPM approach (15 s/3 min versus 360 s/6 min). For all LV function parameters interobserver agreement between the experienced and non-experienced reader was significantly improved when the GPM approach was used. However, end-diastolic and end-systolic volumes were larger for the GPM technique when compared to the SoS method (P 0.121). In both readers and for all parameters variances did not differ significantly (P ≥ 0.409) and the two approaches showed an excellent linear correlation (r > 0.951). Conclusion: Due to its accurate, fast and reproducible assessment of LV function parameters highly accelerated MRI combined with the GPM technique may become the technique of first choice for assessment of LV function in clinical routine.

  17. Control of a Two-Stage Direct Power Converter with a Single Voltage Sensor Mounted in the Intermediary Circuit

    DEFF Research Database (Denmark)

    Klumpner, Christian; Wheeler, P.; Blaabjerg, Frede

    2004-01-01

    Controlling a converter requires not only a powerful processors but also accurate voltage and current sensors and fast and precise analogue-digital converters, which increase the cost per kW of the assembly, especially in the low power range. A matrix converter requires less transducers than a back...... converters but in two stages (AC/DC/AC) without using energy storage in the intermediary circuit. They also offer the possibility to reduce the number of switches compared to the standard single-stage matrix converter. This paper presents a new method to control a two-stage DPC providing sine-wave in sine...

  18. Laser wakefield acceleration

    International Nuclear Information System (INIS)

    Esarey, E.; Ting, A.; Sprangle, P.

    1989-01-01

    The laser wakefield accelerator (LWFA) is a novel plasma based electron acceleration scheme which utilizes a relativistic optical guiding mechanism for laser pulse propagation. In the LWFA, a short, high power, single frequency laser pulse is propagated through a plasma. As the laser pulse propagates, its radial and axial ponderomotive forces nonresonantly generate large amplitude plasma waves (wakefields) with a phase velocity equal to the group velocity of the pulse. A properly phased electron bunch may then be accelerated by the axial wakefield and focused by the transverse wakefield. Optical guiding of the laser pulse in the plasma is necessary in order to achieve high energies in a single stage of acceleration. At sufficiently high laser powers, optical guiding may be achieved through relativistic effects associated with the plasma electrons. Preliminary analysis indicates that this scheme may overcome some of the difficulties present in the plasma beat wave accelerator and in the plasma wakefield accelerator. Analytical and numerical calculations are presented which study both laser pulse propagation within a plasma as well as the subsequent generation of large amplitude plasma waves. In addition, the generation of large amplitude plasma waves in regimes where the plasma waves become highly nonlinear is examined

  19. Specific passage of simian immunodeficiency virus from end-stage disease results in accelerated progression to AIDS in rhesus macaques

    NARCIS (Netherlands)

    Holterman, L.; Niphuis, H.; ten Haaft, P. J.; Goudsmit, J.; Baskin, G.; Heeney, J. L.

    1999-01-01

    To determine whether passage of late-stage variants of simian immunodeficiency virus (SIV) would lead to a more virulent infection and rapid disease progression, a study was designed to examine the effects of selective transmission of SIV from late-stage cases of AIDS in Macaca mulatta. In a uniform

  20. Nebivolol reduces central blood pressure in stage I hypertensive patients: experimental single cohort study

    Directory of Open Access Journals (Sweden)

    Renan Oliveira Vaz-de-Melo

    Full Text Available CONTEXT AND OBJECTIVES: Assessment of central blood pressure (BP has grown substantially over recent years because evidence has shown that central BP is more relevant to cardiovascular outcomes than peripheral BP. Thus, different classes of antihypertensive drugs have different effects on central BP despite similar reductions in brachial BP. The aim of this study was to investigate the effect of nebivolol, a β-blocker with vasodilator properties, on the biochemical and hemodynamic parameters of hypertensive patients.DESIGN AND SETTING: Experimental single cohort study conducted in the outpatient clinic of a university hospital.METHODS: Twenty-six patients were recruited. All of them underwent biochemical and hemodynamic evaluation (BP, heart rate (HR, central BP and augmentation index before and after 3 months of using nebivolol.RESULTS: 88.5% of the patients were male; their mean age was 49.7 ± 9.3 years and most of them were overweight (29.6 ± 3.1 kg/m2 with large abdominal waist (102.1 ± 7.2 cm. There were significant decreases in peripheral systolic BP (P = 0.0020, diastolic BP (P = 0.0049, HR (P < 0.0001 and central BP (129.9 ± 12.3 versus 122.3 ± 10.3 mmHg; P = 0.0083 after treatment, in comparison with the baseline values. There was no statistical difference in the augmentation index or in the biochemical parameters, from before to after the treatment.CONCLUSIONS: Nebivolol use seems to be associated with significant reduction of central BP in stage I hypertensive patients, in addition to reductions in brachial systolic and diastolic BP.

  1. An operation protocol for facilitating start-up of single-stage autotrophic nitrogen removing reactors based on process stoichiometry

    DEFF Research Database (Denmark)

    Mutlu, A. Gizem; Vangsgaard, Anna Katrine; Sin, Gürkan

    2012-01-01

    Start-up and operation of single-stage nitritation/anammox reactor employing complete autotrophic nitrogen can be difficult. Keeping the performance criteria and monitoring the microbial community composition may not be easy or fast enough to take action on time. In this study, a control strategy...

  2. Low voltage ride-through capability control for single-stage inverter-based grid-connected photovoltaic power plant

    DEFF Research Database (Denmark)

    Al-Shetwi, Ali Q.; Sujod, Muhamad Zahim; Blaabjerg, Frede

    2018-01-01

    The low voltage ride-through (LVRT) capability is one of the challenges faced by the integration of large-scale photovoltaic (PV) power stations into electrical grid which has not been fully investigated. Therefore, this paper presents a comprehensive control strategy of single-stage PV power pla...

  3. Optimization of atrazine and imidacloprid removal from water using biochars: Designing single or multi-staged batch adsorption systems.

    Science.gov (United States)

    Mandal, Abhishek; Singh, Neera

    2017-05-01

    Contamination of surface and ground water by pesticides from agricultural runoff and industrial discharge is one of the main causes of aqueous contaminations world over. Biochar, agricultural waste derived highly aromatic substance produced after pyrolysis and carbonification of biomass have exhibited good adsorption capacity for pesticides and can be used to develop on-site bio-purification systems for organic contaminant removal from polluted waters. However, high amounts of adsorbent required in single stage-batch sorption plant increases the cost of water treatment; therefore, multistage plant systems were investigated. Normal (RSBC) and phosphoric acid treated (T-RSBC) rice straw biochars were evaluated for atrazine and imidacloprid sorption and data fitted to the Freundlich isotherm. The adsorption data was modelled to develop single or multi-staged adsorber plants for pesticide removal from water. Both biochars showed significantly high adsorption capacity for imidacloprid and atrazine. Modelling studies using the Freundlich adsorption parameters suggested that the amounts (kg/1000L) of RSBC and T-RSBC for 95% of atrazine removal (10mg/L) in single-, two- and three-staged adsorber plant models were 8.84, 2.44, 1.61kg and 4.47, 1.42, 0.98kg, respectively. Corresponding amounts for 95% imidacloprid removal (10mg/L) were 3.97, 1.22, 0.84kg and 3.98, 1.38, 0.96kg, respectively. Thus, the two-staged model suggested 65-72% reduction in amount of adsorbent required over the single stage model, while the three-staged model suggested 30-34% adsorbent saving over the two-staged plant model. Single and two-staged adsorber plant model findings were validated for atrazine removal using T-RSBC. Results suggested that amounts calculated using modelling studies were fairly accurate. Biochars, as low cost adsorbents for atrazine and imidacloprid removal from contaminated water, can be used to develop low cost adsorber plants based on multiple batch sorption systems for the

  4. Single-site catalyst promoters accelerate metal-catalyzed nitroarene hydrogenation

    KAUST Repository

    Wang, Liang

    2018-04-04

    Atomically dispersed supported metal catalysts are drawing wide attention because of the opportunities they offer for new catalytic properties combined with efficient use of the metals. We extend this class of materials to catalysts that incorporate atomically dispersed metal atoms as promoters. The catalysts are used for the challenging nitroarene hydrogenation and found to have both high activity and selectivity. The promoters are single-site Sn on TiO2 supports that incorporate metal nanoparticle catalysts. Represented as M/Sn-TiO2 (M = Au, Ru, Pt, Ni), these catalysts decidedly outperform the unpromoted supported metals, even for hydrogenation of nitroarenes substituted with various reducible groups. The high activity and selectivity of these catalysts result from the creation of oxygen vacancies on the TiO2 surface by single-site Sn, which leads to efficient, selective activation of the nitro group coupled with a reaction involving hydrogen atoms activated on metal nanoparticles.

  5. Single stage incubators and Hypercapnia during incubation affect the vascularization of the chorioallantoic membrane in broiler embryos.

    Science.gov (United States)

    Fernandes, J I M; Bortoluzzi, C; Schmidt, J M; Scapini, L B; Santos, T C; Murakami, A E

    2017-01-01

    Incubation management can have direct effects on neonate health and consequently affect post-hatching development. The effects of incubation in multiple and single stage incubators with different concentrations of CO 2 were evaluated in terms of the vessel density in the chorioallantoic membrane, hatching, heart morphology, and body development of the neonate up to the tenth day. A total of 2,520 fertile eggs were used and distributed in a completely randomized design with 4 levels of CO 2 in 4 single-stage incubators (4,000; 6,000; 8,000; and 10,000 ppm) and a control treatment based on multiple-stage incubation, totaling 5 treatments. The levels of CO 2 were used during the first 10 d of the incubation period, and after this period, all eggs were submitted to the same level of CO 2 (4,000 ppm). Eggs that were incubated in multiple-stage incubators presented a lower percentage of vessels in the chorioallantoic membrane, lower yolk absorption by the embryo, wall depth of the right ventricle, and greater humidity losses in the eggs when compared to eggs in the single-stage incubators. The eggs submitted to hypercapnia, between 5,000 and 6,000 ppm of CO 2 , had a higher percentage of vessels in the chorioallantoic membrane; the embryos originating from these eggs had higher weight, with higher relative weight of the liver. However, the same levels reduced the yolk absorption. Single-stage incubation with moderate levels of hypercapnia is an efficient tool to be adopted by the hatcheries when attempting to improve chick quality. © 2016 Poultry Science Association Inc.

  6. Single-shot EPI with Nyquist ghost compensation: Interleaved Dual-Echo with Acceleration (IDEA) EPI

    Science.gov (United States)

    Poser, Benedikt A; Barth, Markus; Goa, Pål-Erik; Deng, Weiran; Stenger, V Andrew

    2012-01-01

    Echo planar imaging is most commonly used for BOLD fMRI, owing to its sensitivity and acquisition speed. A major problem with EPI is Nyquist (N/2) ghosting, most notably at high field. EPI data are acquired under an oscillating readout gradient and hence vulnerable to gradient imperfections such as eddy current delays and off-resonance effects, as these cause inconsistencies between odd and even k-space lines after time reversal. We propose a straightforward and pragmatic method herein termed Interleaved Dual Echo with Acceleration (IDEA) EPI: Two k-spaces (echoes) are acquired under the positive and negative readout lobes, respectively, by performing phase blips only before alternate readout gradients. From these two k-spaces, two almost entirely ghost free images per shot can be constructed, without need for phase correction. The doubled echo train length can be compensated by parallel imaging and/or partial Fourier acquisition. The two k-spaces can either be complex-averaged during reconstruction, which results in near-perfect cancellation of residual phase errors, or reconstructed into separate images. We demonstrate the efficacy of IDEA EPI and show phantom and in vivo images at both 3 and 7 Tesla. PMID:22411762

  7. Accelerating Value Creation with Accelerators

    DEFF Research Database (Denmark)

    Jonsson, Eythor Ivar

    2015-01-01

    accelerator programs. Microsoft runs accelerators in seven different countries. Accelerators have grown out of the infancy stage and are now an accepted approach to develop new ventures based on cutting-edge technology like the internet of things, mobile technology, big data and virtual reality. It is also...... and developing the best business ideas and support the due diligence process. Even universities are noticing that the learning experience of the action learning approach is an effective way to develop capabilities and change cultures. Accelerators related to what has historically been associated...... have the same purpose as businesses: To create customers....

  8. More than just a conference : the European Particule Accelerator Conference, EPAC, has developped a distinctive role on the world stage, explains Christine Petit-Jean-Genaz, the EPAC conferences coordinator

    CERN Multimedia

    Maximilien Brice

    2004-01-01

    More than just a conference : the European Particule Accelerator Conference, EPAC, has developped a distinctive role on the world stage, explains Christine Petit-Jean-Genaz, the EPAC conferences coordinator

  9. ACCELERATORS: Design of a 450 MHz β = 0.2 single spoke cavity at PKU

    Science.gov (United States)

    Yao, Zhong-Yuan; Lu, Xiang-Yang; Zhao, Kui

    2009-04-01

    The design of a 450 MHz β = 0.2 superconducting single spoke cavity has been finished at Peking University. A theoretical model and a numerical simulation are used to study the relationship between the RF performance and the geometric parameters of the cavity. In this paper, the optimization of the spoke cavity is described in detail. The RF simulation gives the optimum parameters Epk/Eacc of 2.65 and Bpk/Eacc of 5.22 mT/(MV/m). The mechanical properties of the cavity are also studied. Two stiff ribs are used to offer a credible mechanical stability.

  10. Linear induction accelerators

    International Nuclear Information System (INIS)

    Briggs, R.J.

    1986-06-01

    The development of linear induction accelerators has been motivated by applications requiring high-pulsed currents of charged particles at voltages exceeding the capability of single-stage, diode-type accelerators and at currents too high for rf accelerators. In principle, one can accelerate charged particles to arbitrarily high voltages using a multi-stage induction machine, but the 50-MeV, 10-kA Advanced Test Accelerator (ATA) at LLNL is the highest voltage machine in existence at this time. The advent of magnetic pulse power systems makes sustained operation at high-repetition rates practical, and this capability for high-average power is very likely to open up many new applications of induction machines in the future. This paper surveys the US induction linac technology with primary emphasis on electron machines. A simplified description of how induction machines couple energy to the electron beam is given, to illustrate many of the general issues that bound the design space of induction linacs

  11. Linear induction accelerators

    International Nuclear Information System (INIS)

    Briggs, R.J.

    1986-01-01

    The development of linear induction accelerators has been motivated by applications requiring high-pulsed currents of charged particles at voltages exceeding the capability of single-stage, diode-type accelerators and at currents too high for r.f. accelerators. In principle, one can accelerate charged particles to arbitrarily high voltages using a multi-stage induction machine, but the 50-MeV, 10-kA Advanced Test Accelerator (ATA) at LLNL is the highest voltage machine in existence at this time. The advent of magnetic pulse power systems makes sustained operation at high-repetition rates practical, and this capability for high-average power in very likely to open up many new applications of induction machines in the future. The US induction linac technology is surveyed with primary emphasis on electron machines. A simplified description of how induction machines couple energy to the electron beam is given, to illustrate many of the general issues that bound the design space of induction linacs. A key issue in all high-intensity linacs is that of beam instability

  12. Loss of a single allele for Ku80 leads to progenitor dysfunction and accelerated aging in skeletal muscle

    Science.gov (United States)

    Didier, Nathalie; Hourdé, Christophe; Amthor, Helge; Marazzi, Giovanna; Sassoon, David

    2012-01-01

    Muscle wasting is a major cause of morbidity in the elderly. Ku80 is required for DNA double strand repair and is implicated in telomere maintenance. Complete loss-of-function leads to reduced post-natal growth and severe progeria in mice. We examined the role of Ku80 in age-related skeletal muscle atrophy. While complete loss of Ku80 leads to pronounced aging in muscle as expected, accompanied by accumulation of DNA damage, loss of a single allele is sufficient to accelerate aging in skeletal muscle although post-natal growth is normal. Ku80 heterozygous muscle shows no DNA damage accumulation but undergoes premature telomere shortening that alters stem cell self-renewal through stress response pathways including p53. These data reveal an unexpected requirement for both Ku80 alleles for optimal progenitor function and prevention of early onset aging in muscle, as well as providing a useful model for therapeutic approaches. PMID:22915554

  13. Acceleration for 2D time-domain elastic full waveform inversion using a single GPU card

    Science.gov (United States)

    Jiang, Jinpeng; Zhu, Peimin

    2018-05-01

    Full waveform inversion (FWI) is a challenging procedure due to the high computational cost related to the modeling, especially for the elastic case. The graphics processing unit (GPU) has become a popular device for the high-performance computing (HPC). To reduce the long computation time, we design and implement the GPU-based 2D elastic FWI (EFWI) in time domain using a single GPU card. We parallelize the forward modeling and gradient calculations using the CUDA programming language. To overcome the limitation of relatively small global memory on GPU, the boundary saving strategy is exploited to reconstruct the forward wavefield. Moreover, the L-BFGS optimization method used in the inversion increases the convergence of the misfit function. A multiscale inversion strategy is performed in the workflow to obtain the accurate inversion results. In our tests, the GPU-based implementations using a single GPU device achieve >15 times speedup in forward modeling, and about 12 times speedup in gradient calculation, compared with the eight-core CPU implementations optimized by OpenMP. The test results from the GPU implementations are verified to have enough accuracy by comparing the results obtained from the CPU implementations.

  14. Iterative image reconstruction with a single-board computer employing hardware acceleration

    International Nuclear Information System (INIS)

    Mayans, R.; Rogers, W.L.; Clinthorne, N.H.; Atkins, D.; Chin, I.; Hanao, J.

    1984-01-01

    Iterative reconstruction of tomographic images offers much greater flexibility than filtered backprojection; finite ray width, spatially variant resolution, nonstandard ray geometry, missing angular samples and irregular attenuation maps are all readily accommodated. In addition, various solution strategies such as least square or maximum entropy can be implemented. The principal difficulty is that either a large computer must be used or the computation time is excessive. The authors have developed an image reconstructor based on the Intel 86/12 single-board computer. The design strategy was to first implement a family of reconstruction algorithms in PLM-86 and to identify the slowest common computation segments. Next, double precision arithmetic was recoded and extended addressing calls replaced with in-line code. Finally, the inner loop was shortened by factoring the computation. Computation times for these versions were in the ratio 1:0:75:0.5. Using software only, a single iteration of the ART algorithm for finite beam geometry involving 300k pixel weights could be accomplished in 70 seconds with high quality images obtained in three iterations. In addition the authors examined multibus compatible hardware additions to further speed the computation. The simplest of those schemes, which performs only the forward projection, has been constructed and is being tested. With this addition, computation time is expected to be reduced an additional 40%. With this approach that have combined flexible choice of algorithm with reasonable image reconstruction time

  15. Multi Stage Strategies for Single Point Incremental Forming of a Cup

    DEFF Research Database (Denmark)

    Skjødt, Martin; Bay, Niels; Endelt, Benny

    2008-01-01

    A five stage forming strategy for forming of a circular cylindrical cup with a height/radius ratio of one is presented. Geometrical relations are discussed and theoretical strains are calculated. The influence of forming direction (upwards or downwards) is investigated for the second stage...... comparing explicit FE analysis with experiments. Good agreement is found between calculated and measured thickness distribution, overall geometry and strains. Using the proposed multi stage strategy it is shown possible to produce a cup with a height close to the radius and side parallel to the symmetry...

  16. Rapidly alternating combination of cisplatin-based chemotherapy and hyperfractionated accelerated radiotherapy in split course for Stage IIIA and Stage IIIB non-small cell lung cancer: results of a Phase I-II study by the GOTHA group

    Energy Technology Data Exchange (ETDEWEB)

    Alberto, P.; Mermillod, B. [Hopital Cantonal Geneve, Geneva (Switzerland); Mirimanoff, R.O.; Leyvraz, S.; Nagy-Mignotte, H.; Bolla, M.; Wellmann, D.; Moro, D.; Brambilla, E. [Hopital Cantonal Universitaire, Lausanne (Switzerland)

    1995-08-01

    The prognosis of stage III non-small cell lung cancer (NSCLC) can be improved by a combination of radiotherapy (RT) and chemotherapy (CT). In this study, the GOTHA group evaluated the feasibility, tolerance, tumour response, pattern of failure and effect on survival of a combination alternating accelerated hyperfractionated (AH) RT and CT in patients with tumour stage III NSCLC. Toxic effects were leucopenia, nausea and vomiting, mucositis, diarrhoea, alopecia and peripheral neuropathy. Alternating CT and AHRT, as used in this study, were well tolerated and allowed full dose delivery within less than 12 weeks. Initial response was not predictive of survival. The survival curve is encouraging and the 5 year survival is superior to the 5% generally observed with conventionally fractionated radiotherapy. (author).

  17. SMLocalizer, a GPU accelerated ImageJ plugin for single molecule localization microscopy.

    Science.gov (United States)

    Bernhem, Kristoffer; Brismar, Hjalmar

    2018-01-01

    SMLocalizer combines the availability of ImageJ with the power of GPU processing for fast and accurate analysis of single molecule localization microscopy data. Analysis of 2D and 3D data in multiple channels is supported. Plugin freely available for Fiji and ImageJ2.0 through https://sourceforge.net/projects/smlocalizer/. Plugin also available for continuous updates through ImageJ update system, add http://sites.imagej.net/Cellular-Biophysics-KTH/ as update site in ImageJ. Java and CUDA source code freely available on the web at https://github.com/KristofferBernhem/SMlocalizer. brismar@kth.se. Supplementary data are available at Bioinformatics online. © The Author(s) 2017. Published by Oxford University Press.

  18. Magnetization of a Single Carbonaceous Grain Obtained by Field-Induced Acceleration

    Science.gov (United States)

    Hisayoshi, Keiji; Uyeda, Chiaki

    2017-10-01

    Diamagnetic susceptibility χDIA of single carbonaceous grains were detected by observing their translations induced by field-gradient force in an area of microgravity. Using the above method, χDIA of a small carbonaceous particle is obtained with no interfering signal of the sample holder; it is unnecessary to know the mass of sample. The χDIA values of various materials obtained by the above method agreed fairly well with their published values. By comparing the obtained χDIA value with a list of published values, the material of an unidentified organic grain can be determined without consuming the sample. The principle of magnetic transition is applicable to investigate the magnetic properties of nano-size carbonaceous materials.

  19. Large Conization and Laparoendoscopic Single-Port Pelvic Lymphadenectomy in Early-Stage Cervical Cancer for Fertility Preservation

    Directory of Open Access Journals (Sweden)

    Polat Dursun

    2013-01-01

    Full Text Available Fertility preservation in early-stage cervical cancer is a hot topic in gynecologic oncology. Although radical vaginal trachelectomy (RVT is suggested as a fertility preserving approach, there are some serious concerns like cervical stenosis, second trimester loss, preterm delivery in survivors, and lack of residual tumor in the majority of the surgical specimens. Therefore, less radical surgical operations have been proposed in early-stage cervical carcinomas. On the other hand, single-incision laparoscopic surgery (SILS is an evolving endoscopic approach for minimal access surgery. In this report, we present a case with early-stage cervical cancer who wishes to preserve fertility. We successfully performed single-port pelvic lymphadenectomy and large conization to preserve fertility potential of the patient. We think that combination of less radical approach like conization and single-port pelvic lymphadenectomy might be less minimally invasive and is still an effective surgical approach in well-selected cases with cervical carcinomas. Incorporation of single-port laparoscopy into the minimally invasive fertility sparing management of the cervical cancer will improve patients outcome with less complications and better cosmesis. Further studies are needed to reach a clear conclusion.

  20. Control of a Two-Stage Direct Power Converter with a Single Voltage Sensor Mounted in the Intermediary Circuit

    DEFF Research Database (Denmark)

    Klumpner, Christian; Wheeler, P.; Blaabjerg, Frede

    2004-01-01

    Controlling a converter requires not only a powerful processors but also accurate voltage and current sensors and fast and precise analogue-digital converters, which increase the cost per kW of the assembly, especially in the low power range. A matrix converter requires less transducers than a back......-wave out operation while using a single voltage sensor mounted in the intermediary link between the rectification and the inversion stages and the information of the sign of the input line-to-line voltages, which is needed anyway for the safe-commutation of the rectification stage....

  1. High Power Test of X-band Single Cell HOM-free Choke-mode Damped Accelerating Structure made by Tsinghua University

    OpenAIRE

    Wu, Xiaowei; Abe, Tetsuo; Chen, Huaibi; Higo, Toshiyasu; Shi, Jiaru; Wuensch, Walter; Zha, Hao

    2016-01-01

    As an alternative design for CLIC main accelerating structures, X-band choke-mode damped structures had been studied for several years. However, the performance of choke-mode cavity under high power is still in lack of research. Two standing wave single cell choke-mode damped accelerating structures with different choke dimensions which are working at 11.424 GHz were designed, manufactured and bench tested by accelerator group in Tsinghua University. High power test was carried out on it to s...

  2. Single Port Management: Critical Link in the Reception, Staging, Onward Movement, and Integration Process

    National Research Council Canada - National Science Library

    Bush, Ralph

    1998-01-01

    .... The doctrine on single port management is still evolving and not entirely written. With clearly defined responsibilities and accepted doctrine, our ability to support geographic commanders greatly improves...

  3. Tissue inhibitor of metalloproteinase-4 is elevated in early-stage breast cancers with accelerated progression and poor clinical course.

    Science.gov (United States)

    Liss, Michaelann; Sreedhar, Nandhini; Keshgegian, Albert; Sauter, Guido; Chernick, Michael R; Prendergast, George C; Wallon, U Margaretha

    2009-09-01

    An increasing number of breast cancer patients are diagnosed with small, localized, early-stage tumors. These patients are typically thought to have a good prognosis for long-term disease-free survival, but epidemiological studies indicate that up to 30% may have a recurrence within 3 to 5 years of diagnosis. Identifying patients with a high risk of recurrence and/or progression is important because they could be more aggressively treated at diagnosis to improve their chances for disease-free survival. Recent evidence suggests that elevated levels of the matrix metalloproteinase inhibitor, tissue inhibitor of metalloproteinase (TIMP)-4, are associated with malignant progression of ductal carcinoma in situ, a precancerous lesion. To examine the association of TIMP-4 with survival outcomes, we conducted a retrospective immunohistochemical analysis of 314 cases from patients with early-stage disease, defined as tumors smaller than 2 cm and no spread to lymph nodes (tumor-node-metastasis staging: T1N0MX). We found that tumors with elevated levels of TIMP-4 were correlated with a reduced probability of long-term disease-free survival, especially in patients with estrogen receptor-negative tumors. Our findings prompt further evaluation of TIMP-4 as a simple prognostic marker that may help identify patients with early-stage breast cancer who could benefit from more aggressive treatment at diagnosis.

  4. Effectiveness of surgery and individualized high-dose hyperfractionated accelerated radiotherapy on survival in clinical stage I non-small cell lung cancer. A propensity score matched analysis

    International Nuclear Information System (INIS)

    Jimenez, Marcelo F.; Baardwijk, Angela van; Aerts, Hugo J.W.L.; De Ruysscher, Dirk; Novoa, Nuria M.; Varela, Gonzalo; Lambin, Philippe

    2010-01-01

    Background and purpose: Surgery is considered the treatment of choice for early-stage non-small cell lung cancer (NSCLC). Patients with poor pulmonary function or other comorbidities are treated with radiotherapy. The objective of this investigation is to compare the 3-year survival of two early-stage NSCLC populations treated in two different hospitals, either by surgical resection (lobectomy) or by individualized high-dose accelerated radiotherapy, after matching patients by propensity scoring analysis. Methods: A retrospective comparative study has been performed on two series of consecutive patients with cytohistological diagnosis of NSCLC, clinically staged IA by means of PET-scan (radiotherapy group) and pathologically staged IA (surgery group). Results: A total of 157 cases were initially selected for the analysis (110 operated and 47 treated by radiotherapy). Patients in the radiotherapy group were older, with higher comorbidity and lower FEV1% with 3-years probability of survival for operated patients higher than that found for patients treated by radiotherapy. After matching by propensity scoring (using age and FEV1%), differences disappear and 3-years probability of survival had no statistical differences. Conclusions: Although this is a non-randomized retrospective analysis, we have not found 3-years survival differences after matching cases between surgery and radiotherapy. Nevertheless, data presented here support the continuous investigation for non-surgical alternatives in this disease.

  5. Leveraging accelerated testing of LED drivers to model the reliability of two-stage and multi-channel drivers

    Energy Technology Data Exchange (ETDEWEB)

    Davis, Lynn; Perkins, Curtis; Smith, Aaron; Clark, Terry; Mills, Karmann

    2017-05-30

    The next wave of LED lighting technology is likely to be tunable white lighting (TWL) devices which can adjust the colour of the emitted light between warm white (~ 2700 K) and cool white (~ 6500 K). This type of lighting system uses LED assemblies of two or more colours each controlled by separate driver channels that independently adjust the current levels to achieve the desired lighting colour. Drivers used in TWL devices are inherently more complex than those found in simple SSL devices, due to the number of electrical components in the driver required to achieve this level of control. The reliability of such lighting systems can only be studied using accelerated stress tests (AST) that accelerate the aging process to time frames that can be accommodated in laboratory testing. This paper describes AST methods and findings developed from AST data that provide insights into the lifetime of the main components of one-channel and multi-channel LED devices. The use of AST protocols to confirm product reliability is necessary to ensure that the technology can meet the performance and lifetime requirements of the intended application.

  6. Accelerated repopulation of mouse tongue epithelium during fractionated irradiations or following single doses

    International Nuclear Information System (INIS)

    Doerr, W.; Kummermehr, J.

    1990-01-01

    Mouse tongue mucosa was established as an animal model to study repopulation after large single doses or during continuous irradiation. A top-up irradiation technique was used employing priming doses or fractionated treatment to the whole snout (300 kV X-rays) followed by local test doses (25 kV X-rays) to elicit denudation in a confined field of the inferior tongue surface. Clearcut quantal dose-response curves of ulcer incidence were obtained to all protocols; animal morbidity, i.e. body weight loss was minimal. Repopulation following priming doses of 10 and 13 Gy started with a delay of at least 3 days and then progressed rapidly to nearly restore original tissue tolerance by day 11. During continuous fractionation over 1 to 3 weeks with 5 fractions/week and doses per fraction of 2.5, 3 and 3.5 Gy, repopulation was small in week one but subsequently increased to fully compensate the weekly dose at all dose levels. Additional measurements of cell density during a 4 weeks course of 5 x 3 Gy or 5 x 4 Gy per week showed only moderate depletion to 67% of the control figures. The fact that rapid repopulation is achieved at relatively moderate damage levels should be taken into account when the timing of a treatment split is considered. (author). 18 refs.; 7 figs.; 1 tab

  7. A single aerobic exercise session accelerates movement execution but not central processing.

    Science.gov (United States)

    Beyer, Kit B; Sage, Michael D; Staines, W Richard; Middleton, Laura E; McIlroy, William E

    2017-03-27

    Previous research has demonstrated that aerobic exercise has disparate effects on speed of processing and movement execution. In simple and choice reaction tasks, aerobic exercise appears to increase speed of movement execution while speed of processing is unaffected. In the flanker task, aerobic exercise has been shown to reduce response time on incongruent trials more than congruent trials, purportedly reflecting a selective influence on speed of processing related to cognitive control. However, it is unclear how changes in speed of processing and movement execution contribute to these exercise-induced changes in response time during the flanker task. This study examined how a single session of aerobic exercise influences speed of processing and movement execution during a flanker task using electromyography to partition response time into reaction time and movement time, respectively. Movement time decreased during aerobic exercise regardless of flanker congruence but returned to pre-exercise levels immediately after exercise. Reaction time during incongruent flanker trials decreased over time in both an aerobic exercise and non-exercise control condition indicating it was not specifically influenced by exercise. This disparate influence of aerobic exercise on movement time and reaction time indicates the importance of partitioning response time when examining the influence of aerobic exercise on speed of processing. The decrease in reaction time over time independent of aerobic exercise indicates that interpreting pre-to-post exercise changes in behavior requires caution. Copyright © 2017 IBRO. Published by Elsevier Ltd. All rights reserved.

  8. Single vacancy defects diffusion at the initial stage of graphene growth: A first-principles study

    International Nuclear Information System (INIS)

    Du, H.B.; Jia, Y.; Sun, Q.; Guo, Z.X.

    2015-01-01

    The migration of a single vacancy (SV) defect in graphene fragment (GF) has been investigated by density functional theory (DFT). The results revealed that a single vacancy defect is easy to migrate to the GF edge. The interaction between an SV and a five-numbered ring at the edge results in two neighboring five-membered rings finally, while the interaction between an SV and a seven-membered ring defect at the edge of the GF leads to a five-numbered ring and a neighbor seven-numbered ring. Our findings shed light upon understanding of the growth process of the graphene grain boundary. - Highlights: • The migration of single vacancy in graphene fragment. • The interaction between single vacancy and five- or seven-membered ring. • The possible reason why it is difficult to find single vacancy inside graphene

  9. Effects of Stator Shroud Injection on the Aerodynamic Performance of a Single-Stage Transonic Axial Compressor

    International Nuclear Information System (INIS)

    Dinh, Cong-Truong; Ma, Sang-Bum; Kim, Kwang Yong

    2017-01-01

    In this study, stator shroud injection in a single-stage transonic axial compressor is proposed. A parametric study of the effect of stator shroud injection on aerodynamic performances was conducted using the three-dimensional Reynolds-averaged Navier-Stokes equations. The curvature, length, width, and circumferential angle of the stator shroud injector and the air injection mass flow rate were selected as the test parameters. The results of the parametric study show that the aerodynamic performances of the single-stage transonic axial compressor were improved by stator shroud injection. The aerodynamic performances were the most sensitive to the injection mass flow rate. Further, the total pressure ratio and adiabatic efficiency were the maximum when the ratio of circumferential angle was 10%.

  10. Effects of Stator Shroud Injection on the Aerodynamic Performance of a Single-Stage Transonic Axial Compressor

    Energy Technology Data Exchange (ETDEWEB)

    Dinh, Cong-Truong; Ma, Sang-Bum; Kim, Kwang Yong [Inha Univ., Incheon (Korea, Republic of)

    2017-01-15

    In this study, stator shroud injection in a single-stage transonic axial compressor is proposed. A parametric study of the effect of stator shroud injection on aerodynamic performances was conducted using the three-dimensional Reynolds-averaged Navier-Stokes equations. The curvature, length, width, and circumferential angle of the stator shroud injector and the air injection mass flow rate were selected as the test parameters. The results of the parametric study show that the aerodynamic performances of the single-stage transonic axial compressor were improved by stator shroud injection. The aerodynamic performances were the most sensitive to the injection mass flow rate. Further, the total pressure ratio and adiabatic efficiency were the maximum when the ratio of circumferential angle was 10%.

  11. Area G perimeter surface-soil and single-stage water sampling: Environmental surveillance for fiscal year 95. Progress report

    Energy Technology Data Exchange (ETDEWEB)

    Childs, M.; Conrad, R.

    1997-09-01

    ESH-19 personnel collected soil and single-stage water samples around the perimeter of Area G at Los Alamos National Laboratory (LANL) during FY 95 to characterize possible radionuclide movement out of Area G through surface water and entrained sediment runoff. Soil samples were analyzed for tritium, total uranium, isotopic plutonium, americium-241, and cesium-137. The single-stage water samples were analyzed for tritium and plutonium isotopes. All radiochemical data was compared with analogous samples collected during FY 93 and 94 and reported in LA-12986 and LA-13165-PR. Six surface soils were also submitted for metal analyses. These data were included with similar data generated for soil samples collected during FY 94 and compared with metals in background samples collected at the Area G expansion area.

  12. Modeling of DNA single stage splicing language via Yusof-Goode approach: One string with two rules

    Science.gov (United States)

    Lim, Wen Li; Yusof, Yuhani; Mudaber, Mohammad Hassan

    2015-02-01

    Splicing system plays a pivotal role in attempts to recombine sets of double-stranded DNA molecules when acted by restriction enzymes and ligase. Traditional method of finding the result of DNA recombination through experiment is both time and money consuming. Hence, finding the number of patterns of DNA single stage splicing language through formalism of splicing system is a way to optimize the searching process. From the biological perspective, it predicts the number of types of molecules that will exist in the system under existence of restriction enzymes and ligase. In this paper, some theorems, corollaries and examples that lead to the predictions of single stage splicing languages involving one pattern string and two rules are presented via Yusof-Goode approach.

  13. Adjuvant Radiotherapy for Stages II and III Resected Thymoma: A Single-institutional Experience.

    Science.gov (United States)

    Yan, Jinchun; Liu, Qin; Moseley, Jessica N; Baik, Christina S; Chow, Laura Q M; Goulart, Bernardo H M; Zlotnick, David; Papanicolau-Sengos, Antoni; Gallaher, Ian; Knopp, Joy M; Zeng, Jing; Patel, Shilpen

    2016-06-01

    The role of adjuvant radiation for Masaoka stages II and III thymoma remains controversial. The aim of this study was to evaluate the clinical benefit of radiation therapy for resected stages II and III thymoma patients. We retrospectively reviewed the medical records of 175 thymoma patients treated from July 1996 to January 2013 at University of Washington Medical Center; 88 patients with adequate follow-up and who met histologic criteria were included. We evaluated progression-free survival (PFS) and overall survival (OS), and compared these outcomes in patients treated by surgery (S) alone versus surgery plus radiotherapy (S+RT). Cox regression models and log-rank tests were used to compare PFS and OS for S versus S+RT, and they were further assessed by margin-positive versus margin-negative subgroups using Kaplan-Meier curves. Among the 88 thymoma patients, 22 were stage II and 18 were stage III. For all stages II and III patients, adjuvant radiation was not identified as a significant predictor for PFS (P=0.95) or OS (P=0.63). A positive surgical margin predicted for a worse OS (hazard ratio=7.1; P=0.004). Further investigation revealed for resection margin-positive patients; S+RT had higher OS than S alone (P=0.006). For stages II and III thymoma, postoperative adjuvant radiation was not associated with statistically significant differences in PFS or OS in this study. Our results indicated a potential OS benefit of adjuvant RT in patients with positive resection margins, and therefore may be considered in this patient population.

  14. Adjuvant Radiotherapy for Stages II and III Resected Thymoma: a Single Institution Experience

    Science.gov (United States)

    Yan, Jinchun; Liu, Qin; Moseley, Jessica N.; Baik, Christina S.; Chow, Laura Q. M.; Goulart, Bernardo H. M.; Zlotnick, David; Papanicolau-Sengos, Antoni; Gallaher, Ian; Knopp, Joy M.; Zeng, Jing; Patel, Shilpen

    2016-01-01

    Purpose Role of adjuvant radiation for Masaoka stage II and III thymoma remains controversial. The aim of this study was to evaluate the clinical benefits of radiation therapy for resected stages II and III thymoma. Methods and Materials We retrospectively reviewed the medical records of 175 thymoma patients treated from July 1996 to January 2013 at University of Washington Medical Center; 88 patients with adequate follow-up and who met histologic criteria were included. We evaluated progression-free survival (PFS) and overall survival (OS), and compared these outcomes in patients treated by surgery (S) alone versus surgery plus radiotherapy (S + RT). Cox regression models and log-rank tests were used to compare PFS and OS for S versus S + RT, and they were further assessed by margin-positive versus margin-negative subgroups using Kaplan-Meier curves. Results Among the 88 thymoma patients, 22 were stage II and 18 were stage III. For all stages II and III patients, adjuvant radiation was not identified as a significant predictor for PFS (P = 0.95) or OS (P = 0.63). A positive surgical margin predicted for a worse OS (hazard ratio = 7.1; P = 0.004). Further investigation revealed for resection margin-positive patients; S + RT had higher OS than S alone (P = 0.006). Conclusions For stages II and III thymoma, postoperative adjuvant radiation was not associated with statistically significant differences in PFS or OS in this study. Our results indicated a potential OS benefit of adjuvant RT in patients with positive resection margins, and therefore may be considered in this patient population. PMID:24517958

  15. Performance analysis of a single stage four bed metal hydride cooling system, part A: Influence of mass recovery

    Energy Technology Data Exchange (ETDEWEB)

    Abraham, Kevin; Prakash Maiya, M.; Srinivasa Murthy, S. [Refrigeration and Air-conditioning Laboratory, Department of Mechanical Engineering, Indian Institute of Technology Madras, 600036, Chennai (India)

    2003-01-01

    The concept of mass recovery in metal hydride systems is studied with a single stage multi-bed cooling system as example. Mass recovery results in variation of bed temperatures due to removal or addition of heat of desorption or absorption respectively. Coefficient of performance and cold output increase while required heat input decreases for the mass recovery cycle. Thus mass recovery between hydride reactors is found to improve system performance compared to that of a basic system. (authors)

  16. Single-stage revision from gastric band to gastric bypass or sleeve gastrectomy: 6- and 12-month outcomes.

    Science.gov (United States)

    Yeung, Louise; Durkan, Brandice; Barrett, Allison; Kraft, Cary; Vu, Kim; Phillips, Edward; Cunneen, Scott; Burch, Miguel

    2016-06-01

    Laparoscopic adjustable gastric banding (LAGB) is increasingly requiring revisional surgery for complications and failures. Removal of the band and conversion to either laparoscopic Roux-en-y gastric bypass (LRYGB) or laparoscopic sleeve gastrectomy (LSG) is feasible as a single-stage procedure. The objective of this study is to compare the safety and efficacy of single-stage revision from LAGB to either LRYGB or LSG at 6 and 12 months postoperatively. Retrospective analysis was performed on patients undergoing single-stage revision between 2009 and 2014 at a single academic medical center. Patients were reassessed for weight loss and complications at 6 and 12 months postoperatively. Thirty-two patients underwent single-stage revision to LRYGB, and 72 to LSG. Preoperative BMIs were similar between the two groups (p = 0.27). Median length of stay for LRYGB was 3 days versus 2 for LSG (p = 0.14). Four patients in the LRYGB group required reoperation within 30 days, and two patients in the LSG group required reoperation within 30 days (p = 0.15). There was no difference in ER visits (p = 0.24) or readmission rates (p = 0.80) within 30 days of operation. Six delayed complications were seen in the LSG group with three requiring intervention. At 6 months postoperatively, percent excess weight loss (%EWL) was 50.20 for LRYGB and 30.64 for LSG (p = 0.056). At 12 months, %EWL was 51.19 for LRYGB and 34.89 for LSG (p = 0.31). There was no difference in diabetes or hypertension medication reduction at 12 months between LRYGB and LSG (p > 0.07). Single-stage revision from LAGB to LRYGB or LSG is technically feasible, but not without complications. The complications in the bypass group were more severe. There was no difference in readmission or reoperation rates, weight loss or comorbidity reduction. Revision to LRYGB trended toward higher rate and greater severity of complications with equivalent weight loss and comorbidity reduction.

  17. Numerical simulations of single and multi-staged injection of H2 in a supersonic scramjet combustor

    Directory of Open Access Journals (Sweden)

    L. Abu-Farah

    2014-12-01

    Full Text Available Computational fluid dynamics (CFD simulations of a single staged injection of H2 through a central wedge shaped strut and a multi-staged injection through wall injectors are carried out by using Ansys CFX-12 code. Unstructured tetrahedral grids for narrow channel and quarter geometries of the combustor are generated by using ICEM CFD. Steady three-dimensional (3D Reynolds-averaged Navier-stokes (RANS simulations are carried out in the case of no H2 injection and compared with the simulations of single staged pilot and/or main H2 injections and multistage injection. Shear stress transport (SST based on k-ω turbulent model is adopted. Flow field visualization (complex shock waves interactions and static pressure distribution along the wall of the combustor are predicted and compared with the experimental schlieren images and measured wall static pressures for validation. A good agreement is found between the CFD predicted results and the measured data. The narrow and quarter geometries of the combustor give similar results with very small differences. Multi-staged injections of H2 enhance the turbulent H2/air mixing by forming vortices and additional shock waves (bow shocks.

  18. ''SMILE'': A Self Magnetically Insulated Transmission LinE adder for the 8-stage RADLAC II accelerator

    International Nuclear Information System (INIS)

    Mazarakis, M.G.; Poukey, J.W.; Shope, S.L.; Frost, C.A.; Turman, B.N.; Ramirez, J.J.; Prestwich, K.R.; Pankuch, P.J.

    1991-01-01

    The RADLAC II Self Magnetically Insulated Transmission LinE ''SMILE'' is a coaxial wave guide structure that is composed of two regions: (a) a 9.5-m voltage adder and (b) a 3-m long extension section. The adder section provides for the addition of the input voltages from the individual water-dielectric pulse forming line feeds. The extension section isolates the adder from the magnetically immersed foilless diode electron source load and efficiently transports the pulsed power out from the deionized water tank of the device. The SMILE modification of the RADLAC II accelerator enabled us to produce high quality beams of up to 14 MV, 100 kA. The design and the experimental evaluation of SMILE will be presented and compared with numerical simulation predictions. 12 refs., 9 figs., 1 tab

  19. SMILE'': A Self Magnetically Insulated Transmission LinE adder for the 8-stage RADLAC II accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Mazarakis, M.G.; Poukey, J.W.; Shope, S.L.; Frost, C.A.; Turman, B.N.; Ramirez, J.J.; Prestwich, K.R. (Sandia National Labs., Albuquerque, NM (USA)); Pankuch, P.J. (EG and G Energy Measurements Group, Inc., Albuquerque, NM (USA). Special Projects)

    1991-01-01

    The RADLAC II Self Magnetically Insulated Transmission LinE SMILE'' is a coaxial wave guide structure that is composed of two regions: (a) a 9.5-m voltage adder and (b) a 3-m long extension section. The adder section provides for the addition of the input voltages from the individual water-dielectric pulse forming line feeds. The extension section isolates the adder from the magnetically immersed foilless diode electron source load and efficiently transports the pulsed power out from the deionized water tank of the device. The SMILE modification of the RADLAC II accelerator enabled us to produce high quality beams of up to 14 MV, 100 kA. The design and the experimental evaluation of SMILE will be presented and compared with numerical simulation predictions. 12 refs., 9 figs., 1 tab.

  20. Theoretical comparison of single-stage and advanced absorption heat transformers used to increase solar pond's temperature

    Energy Technology Data Exchange (ETDEWEB)

    Rivera, W; Best, Roberto [Centro de Investigacion en Energia-UNAM, Temixco, Morelos (Mexico)

    2000-07-01

    Mathematical models of single-stage and advanced absorption heat transformers operating with the water/Carrol{sup T}M mixture were developed to simulate the performance of these systems coupled to a solar pond in order to increase the temperature of the useful heat produced by solar ponds. The results showed that the single-stage and the double absorption heat transformer are the most promising configuration to be coupled to solar ponds. With single-stage heat transformers it is possible to increase solar pond's temperature until 50 Celsius degrees with coefficients of performance of about 0.48 and with double absorption heat transformers until 100 Celsius degrees with coefficients of performance of 0.33. [Spanish] Se desarrollaron modelos matematicos de una sola etapa y transformadores avanzados de absorcion de calor operando con la mezcla agua/Carrol{sup T}M para simular el rendimiento de estos sistemas acoplados a un estanque solar con el objeto de aumentar la temperatura del calor util producido por los estanques solares. Los resultados mostraron que la etapa sencilla y el transformador de calor de absorcion doble son la configuracion mas prometedora para ser acoplado a estanques solares. Con los transformadores de calor de una sola etapa es posible aumentar la temperatura del estanque solar hasta 50 grados Celsius con coeficientes de rendimiento de alrededor de 0.48 y con transformadores de calor de doble absorcion hasta 100 grados Celsius con coeficientes de rendimiento de 0.33.

  1. How can recovery be enhanced after single-stage laparoscopic management of CBD stones? Endoscopic treatment versus laparoscopic surgery.

    Science.gov (United States)

    Chapuis-Roux, Emilie; Pellissier, Laurent; Browet, Francois; Berthou, Jean Charles; Hakim, Sami; Brazier, Franck; Cosse, Cyril; Delcenserie, Richard; Regimbeau, Jean Marc

    2017-07-01

    Single-stage management of CBD stones comprises simultaneous common bile duct (CBD) clearance and cholecystectomy. The CBD can be cleared by using endoscopic treatment (ET) or laparoscopic surgery (LS) alone. To determine the most rapid recovery after the single-stage laparoscopic management of CBD stones. Patients with CBD stones treated at either of two centers (one performing ET only and one performing LS only for single-stage treatment) were included. The primary endpoint was "the textbook outcome". The feasibility rate was 74% for ET and 100% for LS (p≤0.001). The proportion of cases with the textbook outcome was higher in the ET group than in the LS-only group (73% vs. 10%; pCBD clearance rate was similar in the ET and LS-only groups (100% vs. 96.6%, respectively; p=0.17). The overall morbidity rate was lower in the ET group than in the LS-only group (23% vs. 29%, p=0.05). Both ET and LS are feasible, safe and effective for clearance of the CBD. ET was better than LS in terms of a less frequent requirement for drainage and a shorter length of hospital stay. LS was associated with a shorter operating time. Copyright © 2017 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  2. Dual matrix ordered subsets reconstruction for accelerated 3D scatter compensation in single-photon emission tomography

    International Nuclear Information System (INIS)

    Kamphuis, C.; Beekman, F.J.; Van Rijk, P.P.; Viergever, M.A.

    1998-01-01

    Three-dimensional (3D) iterative maximum likelihood expectation maximization (ML-EM) algorithms for single-photon emission tomography (SPET) are capable of correcting image-degrading effects of non-uniform attenuation, distance-dependent camera response and patient shape-dependent scatter. However, the resulting improvements in quantitation, resolution and signal-to-noise ratio (SNR) are obtained at the cost of a huge computational burden. This paper presents a new acceleration method for ML-EM: dual matrix ordered subsets (DM-OS). DM-OS combines two acceleration methods: (a) different matrices for projection and back-projection and (b) ordered subsets of projections. DM-OS was compared with ML-EM on simulated data and on physical thorax phantom data, for both 180 and 360 orbits. Contrast, normalized standard deviation and mean squared error were calculated for the digital phantom experiment. DM-OS resulted in similar image quality to ML-EM, even for speed-up factors of 200 compared to ML-EM in the case of 120 projections. The thorax phantom data could be reconstructed 50 times faster (60 projections) using DM-OS with preservation of image quality. ML-EM and DM-OS with scatter compensation showed significant improvement of SNR compared to ML-EM without scatter compensation. Furthermore, inclusion of complex image formation models in the computer code is simplified in the case of DM-OS. It is thus shown that DM-OS is a fast and relatively simple algorithm for 3D iterative scatter compensation, with similar results to conventional ML-EM, for both 180 and 360 acquired data. (orig.)

  3. A 0.18 {mu}m CMOS single-inductor single-stage quadrature frontend for GNSS receiver

    Energy Technology Data Exchange (ETDEWEB)

    Li Bing; Zhuang Yiqi; Han Yeqi; Xing Xiaoling; Li Zhenrong; Long Qiang, E-mail: waxmax@126.com [Key Laboratory of the Ministry of Education for Wide Bandgap Semiconductor Materials and Devices, School of Microelectronics, Xidian University, Xi' an 710071 (China)

    2011-09-15

    This paper presents an improved merged architecture for a low-IF GNSS receiver frontend, where the bias current and functions are reused in a stacked quadrature LNA-mixer-VCO. Only a single spiral inductor is implemented for the LC resonator and an extra 1/2 frequency divider is added as the quadrature LO signal generator. The details of the design are presented. The gain plan and noise figure are discussed. The phase noise, quadrature accuracy and power consumption are improved. The test chip is fabricated though a 0.18 {mu}m RF CMOS process. The measured noise figure is 5.4 dB on average, with a gain of 43 dB and a IIP3 of -39 dBm. The measured phase noise is better than -105 dBc/Hz at 1 MHz offset. The total power consumption is 19.8 mW with a 1.8 V supply. The experimental results satisfy the requirements for GNSS applications. (semiconductor integrated circuits)

  4. Single Stage Reconstruction of Type IIA Defect of the Ear Lobule ...

    African Journals Online (AJOL)

    technique using a doubled‑over skin flap allows a one stage reconstruction of the ear lobule. It is technically simple and may be performed under local anesthesia. The aesthetic results are generally well acceptable and there is a good color match between the neolobule and the surrounding skin. Key words: Ear lobule, ...

  5. Strain Paths and Fractures in Rotational Symmetric Multi Stage Single Point Incremental Forming

    DEFF Research Database (Denmark)

    Skjødt, Martin; Silva, M.B.; Martins, P.A.F.

    2008-01-01

    A multi stage strategy, which allows forming of SPIF parts with vertical walls, is investigated with emphasis on strain paths and fracture strains. Whereas downwards movement of the tool pin results in deformation close to plane strain upwards moving tool results in biaxial strains. A good correl...

  6. Design model for bending vibrations of single-stage tunnel fan rotor

    Science.gov (United States)

    Krasyuk, AM; Kosykh, PV

    2018-03-01

    Using of one-mass model of tunnel fan rotor is justified for estimation calculation of the natural bending vibrations frequency during the design stage. It’s shown that the evaluative computation of the main axial tunnel fan at the early design stage yields the acceptable accuracy. It is shown that after completion of the design, the mass of the stepped-type shaft differs from the mass of the calculated uniform-diameter shaft no more than by 40%. Inclusion of this additional mass in the estimation calculation makes it possible to improve the calculation accuracy. The region of the dimensionless rotor design parameters at which the relative difference of frequency in the evaluative and verification calculations is not higher than 5 % is determined.

  7. Weibull aging models for the single protective channel unavailability analysis by the device of stages

    International Nuclear Information System (INIS)

    Nunes, M.E.C.; Noriega, H.C.; Melo, P.F.F.

    1997-01-01

    Among the features to take into account in the unavailability analysis of protective channels, there is one that plays a dominant role - that of considering the equipment aging. In this sense, the exponential failure model is not adequate, since some transition rates are no more constant. As a consequence, Markovian models cannot be used anymore. As an alternative, one may use the device of stages that allows for transforming a Non Markovian model into an equivalent Markovian one by insertion of a fictitious states set, called stages. For a given time-dependent transition rate, its failure density is analysed as to the best combination of exponential distributions and then the moments of the original distribution and those of the combination are matched to estimate the necessary parameters. In this paper, the aging of the protective channel is supposed to follow Weibull distributions. Typical means and variances for the times to failure are considered and combinations of stages are checked. Initial conditions features are discussed in connection with states that are fictitious and to check the validity of the developed models. Alternative solutions by the discretization of the failure rates are generated. The results obtained agree quite well. (author). 7 refs., 6 figs

  8. Dynamic variability of the heading-flowering stages of single rice in China based on field observations and NDVI estimations.

    Science.gov (United States)

    Zhang, Zhao; Song, Xiao; Chen, Yi; Wang, Pin; Wei, Xing; Tao, Fulu

    2015-05-01

    Although many studies have indicated the consistent impact of warming on the natural ecosystem (e.g., an early flowering and prolonged growing period), our knowledge of the impacts on agricultural systems is still poorly understood. In this study, spatiotemporal variability of the heading-flowering stages of single rice was detected and compared at three different scales using field-based methods (FBMs) and satellite-based methods (SBMs). The heading-flowering stages from 2000 to 2009 with a spatial resolution of 1 km were extracted from the SPOT/VGT NDVI time series data using the Savizky-Golay filtering method in the areas in China dominated by single rice of Northeast China (NE), the middle-lower Yangtze River Valley (YZ), the Sichuan Basin (SC), and the Yunnan-Guizhou Plateau (YG). We found that approximately 52.6 and 76.3 % of the estimated heading-flowering stages by a SBM were within ±5 and ±10 days estimation error (a root mean square error (RMSE) of 8.76 days) when compared with those determined by a FBM. Both the FBM data and the SBM data had indicated a similar spatial pattern, with the earliest annual average heading-flowering stages in SC, followed by YG, NE, and YZ, which were inconsistent with the patterns reported in natural ecosystems. Moreover, diverse temporal trends were also detected in the four regions due to different climate conditions and agronomic factors such as cultivar shifts. Nevertheless, there were no significant differences (p > 0.05) between the FBM and the SBM in both the regional average value of the phenological stages and the trends, implying the consistency and rationality of the SBM at three scales.

  9. Induction accelerators and free-electron lasers at LLNL

    International Nuclear Information System (INIS)

    Briggs, R.J.

    1989-01-01

    Linear induction accelerators have been developed to produce pulses of charged particles at voltages exceeding the capabilities of single-stage, diode-type accelerators and at currents too high for rf accelerators. In principle, one can accelerate charged particles to arbitrarily high voltages using a multi-stage induction machine. The advent of magnetic pulse power systems makes sustained operation at high repetition rates practical, and high-average-power capability is very likely to open up many new applications of induction machines

  10. Approaches to building single-stage AC/AC conversion switch-mode audio power amplifiers

    DEFF Research Database (Denmark)

    Ljusev, Petar; Andersen, Michael Andreas E.

    2004-01-01

    This paper discusses the possible topologies and promising approaches towards direct single-phase AC-AC conversion of the mains voltage for audio applications. When compared to standard Class-D switching audio power amplifiers with a separate power supply, it is expected that direct conversion...

  11. Pilot study of human recombinant interferon gamma and accelerated hyperfractionated thoracic radiation therapy in patients with unresectable stage IIIA/B nonsmall cell lung cancer

    International Nuclear Information System (INIS)

    Shaw, Edward G.; Deming, Richard L.; Creagan, Edward T.; Nair, Suresh; Su, John Q.; Levitt, Ralph; Steen, Preston D.; Wiesenfeld, Martin; Mailliard, James A.

    1995-01-01

    Purpose: Gamma interferon has a wide range of properties, including the ability to sensitize solid tumor cells to the effects of ionizing radiation. The North Central Cancer Treatment Group has previously completed pilot studies of accelerated hyperfractionated thoracic radiation therapy (AHTRT) in patients with unresectable Stage IIIA/B nonsmall cell lung cancer (NSCLC). This Phase I study was designed to assess the toxicity of concomitant gamma interferon and AHTRT in a similar patient population. Methods and Materials: Between December 1991 and May 1992, 18 patients with unresectable Stage IIIA/B NSCLC were treated with daily gamma interferon (0.2 mg subcutaneously) concomitant with AHTRT (60 Gy given in 1.5 Gy twice daily fractions). All patients had an Eastern Cooperative Oncology Group performance status of 0 or 1 with weight loss < 5%. Eight patients had Stage IIIA and 10 had Stage IIIB disease. Results: Nine patients (50%) experienced severe, life-threatening, or fatal toxicities. Eight of the patients (44%) developed significant radiation pneumonitis, which was severe in six patients and fatal in two patients (11% treatment-related mortality). Two patients (11%) developed severe radiation esophagitis. With follow-up of 15-21 months, 2 patients are alive, and 16 have died. The median survival time and 1-year survival rate is 7.8 months and 38%, respectively. Conclusion: Gamma interferon appeared to sensitize normal lung tissue to the effects of radiation, as demonstrated by the high incidence of severe or fatal radiation pneumonitis. We do not recommend pursuing gamma interferon as a radiosensitizer in this setting

  12. A single cidofovir treatment rescues animals at progressive stages of lethal orthopoxvirus disease

    Directory of Open Access Journals (Sweden)

    Israely Tomer

    2012-06-01

    Full Text Available Abstract Background In an event of a smallpox outbreak in humans, the window for efficacious treatment by vaccination with vaccinia viruses (VACV is believed to be limited to the first few days post-exposure (p.e.. We recently demonstrated in a mouse model for human smallpox, that active immunization 2–3 days p.e. with either VACV-Lister or modified VACV Ankara (MVA vaccines, can rescue animals from lethal challenge of ectromelia virus (ECTV, the causative agent of mousepox. The present study was carried out in order to determine whether a single dose of the anti-viral cidofovir (CDV, administered at different times and doses p.e. either alone or in conjunction with active vaccination, can rescue ECTV infected mice. Methods Animals were infected intranasally with ECTV, treated on different days with various single CDV doses and monitored for morbidity, mortality and humoral response. In addition, in order to determine the influence of CDV on the immune response following vaccination, both the "clinical take”, IFN-gamma and IgG Ab levels in the serum were evaluated as well as the ability of the mice to withstand a lethal challenge of ECTV. Finally the efficacy of a combined treatment regime of CDV and vaccination p.e. was determined. Results A single p.e. CDV treatment is sufficient for protection depending on the initiation time and dose (2.5 – 100 mg/kg of treatment. Solid protection was achieved by a low dose (5 mg/kg CDV treatment even if given at day 6 p.e., approximately 4 days before death of the control infected untreated mice (mean time to death (MTTD 10.2. At the same time point complete protection was achieved by single treatment with higher doses of CDV (25 or 100 mg/kg. Irrespective of treatment dose, all surviving animals developed a protective immune response even when the CDV treatment was initiated one day p.e.. After seven days post treatment with the highest dose (100 mg/kg, virus was still detected in some

  13. Robotic-assisted transperitoneal aortic lymphadenectomy as part of staging procedure for gynaecological malignancies: single institution experience.

    Science.gov (United States)

    Zanagnolo, V; Rollo, D; Tomaselli, T; Rosenberg, P G; Bocciolone, L; Landoni, F; Aletti, G; Peiretti, M; Sanguineti, F; Maggioni, A

    2013-01-01

    Introduction. This study was designed to confirm the feasibility and safety of robotic-assisted transperitoneal aortic lymphadenectomy as part of staging procedure for gynecologic malignancies. Methods. Chart review of 51 patients who had undergone robotic staging with aortic lymphadenectomy for different gynaecologic malignancies was performed. Results. The primary diagnosis was as follows: 6 cases of endometrial cancer, 31 epithelial ovarian cancer, 9 nonepithelial ovarian cancer, 4 tubal cancer, and 1 cervical cancer. Median BMI was 23 kg/m(2). Except for a single case of aortic lymphadenectomy only, both aortic and pelvic lymphadenectomies were performed at the time of the staging procedure. All the para-aortic lymphadenectomies were carried out to the level of the renal veinl but 6 cases were carried out to the level of the inferior mesenteric artery. Hysterectomy was performed in 24 patiens (47%). There was no conversion to LPT. The median console time was 285 (range 195-402) with a significant difference between patients who underwent hysterectomy and those who did not. The median estimated blood loss was 50 mL (range 20-200). The mean number of removed nodes was 29 ± 9.6. The mean number of pelvic nodes was 15 ± 7.6, whereas the mean number of para-aortic nodes was 14 ± 6.6. Conclusions. Robotic transperitoneal infrarenal aortic lymphadenectomy as part of staging procedure is feasible and can be safely performed. Additional trocars are needed when pelvic surgery is also performed.

  14. Single-channel EEG sleep stage classification based on a streamlined set of statistical features in wavelet domain.

    Science.gov (United States)

    da Silveira, Thiago L T; Kozakevicius, Alice J; Rodrigues, Cesar R

    2017-02-01

    The main objective of this study was to enhance the performance of sleep stage classification using single-channel electroencephalograms (EEGs), which are highly desirable for many emerging technologies, such as telemedicine and home care. The proposed method consists of decomposing EEGs by a discrete wavelet transform and computing the kurtosis, skewness and variance of its coefficients at selected levels. A random forest predictor is trained to classify each epoch into one of the Rechtschaffen and Kales' stages. By performing a comprehensive set of tests on 106,376 epochs available from the Physionet public database, it is demonstrated that the use of these three statistical moments has enhanced performance when compared to their application in the time domain. Furthermore, the chosen set of features has the advantage of exhibiting a stable classification performance for all scoring systems, i.e., from 2- to 6-state sleep stages. The stability of the feature set is confirmed with ReliefF tests which show a performance reduction when any individual feature is removed, suggesting that this group of feature cannot be further reduced. The accuracies and kappa coefficients yield higher than 90 % and 0.8, respectively, for all of the 2- to 6-state sleep stage classification cases.

  15. Approaches to building single-stage AC/AC conversion switch-mode audio power amplifiers

    Energy Technology Data Exchange (ETDEWEB)

    Ljusev, P.; Andersen, Michael A.E.

    2005-07-01

    This paper discusses the possible topologies and promising approaches towards direct single-phase AC-AC conversion of the mains voltage for audio applications. When compared to standard Class-D switching audio power amplifiers with a separate power supply, it is expected that direct conversion will provide better efficiency and higher level of integration, leading to lower component count, volume and cost, but at the expense of a minor performance deterioration. (au)

  16. Single-stage treatment of infected tibial non-unions and osteomyelitis with bone marrow granulocytes precursors protecting bone graft.

    Science.gov (United States)

    Hernigou, Philippe; Dubory, Arnaud; Homma, Yasuhiro; Flouzat Lachaniette, Charles Henri; Chevallier, Nathalie; Rouard, Helene

    2017-11-13

    Infected non-unions present a clinical challenge, especially with risk of recurrent infection. Bone marrow contains granulocyte precursors identified in vitro as colony forming units-granulocyte macrophage (CFU-GM) have a prophylactic action against infection. We therefore tested the hypothesis that bone marrow concentrated granulocytes precursors added to a standard bone graft could decrease the risk of recurrence of infection when single-stage treatment of infected tibial non-unions is performed with bone graft. During a single-stage procedure 40 patients with infected tibial non-union received a spongious bone graft supercharged with granulocytes precursors after debridement (study group). A control group (40 patients) was treated in a single stage with local debridement and standard bone graft obtained from the iliac crest. The antibiotic therapy protocol was the same (60 days) in the two groups. CFU-GM progenitors were harvested from bone marrow aspirated on the opposite iliac crest of the site where the cancellous bone was obtained. Union (radiographs and CT scan), a recurrence of clinical infection, and need for subsequent surgery were evaluated. Thirty-eight (95%) patients who received graft supercharged with granulocytes precursors achieved successful union without recurrence of infection during the seven-year follow-up versus 28 (70%) control patients; for the control group the mean graft resorption volume was 40%, while no bone graft resorption was found for the study group. Supercharging the cancellous bone graft with bone marrow granulocytes precursors protect the site of infected non-union from recurrence of infection and bone resorption of the graft.

  17. Single-port one-stage bilateral thoracoscopic sympathicotomy for severe hyperhidrosis: prospective analysis of a standardized approach

    Science.gov (United States)

    2013-01-01

    Background Primary palmar and/or axillary focal hyperhidrosis is a frequent disorder characterized by excessive sweating beyond physiological needs, often leading to a substantial impairment of quality of life. Over the years several minimally invasive surgical treatments have been described, however results vary, and due to a lack of uniform surgical approach, technique and nomenclature are often difficult to compare. In this prospective study we sought to evaluate the safety and effectiveness of our standardized technique of single-port, one-stage bilateral thoracoscopic sympathicotomy. Methods On a prospective basis a hundred consecutive patients with severe or intolerable primary hyperhidrosis underwent one-stage bilateral single-port thoracoscopic sympathicotomy. Primary outcome was measured in pre- vs. post-operative Hyperhidrosis Disease Severity Scale scores. Location and extend of compensatory hyperhidrosis, and satisfaction with the procedure were registered. Results A significant reduction in mean Hyperhidrosis Disease Severity Scale score (3.69 ± 0.47 preoperatively vs. 1.06 ± 0.34 postoperatively) (p 80% reduction in sweat production was achieved. Compensatory hyperhidrosis was seen in 27 patients (27%). It was rated as mild by 21 patients (78%) and as moderate by 6 (22%) of these patients. No severe compensatory hyperhidrosis was reported. Major complications, such as intraoperative bleeding, infections, and Horner’s syndrome were not observed. Conclusions Highly selective sympathicotomy at well-defined levels with a one-stage bilateral single-port transaxillary thoracoscopic approach is a save procedure, with excellent and reproducible immediate results in the treatment of primary palmar and/or axillary hyperhidrosis. PMID:24279511

  18. Tumour burden in early stage Hodgkin's disease: the single most important prognostic factor for outcome after radiotherapy

    DEFF Research Database (Denmark)

    Specht, L; Nordentoft, A M; Cold, Søren

    1987-01-01

    --from 15 to 146 months after initiation of therapy. The initial tumour burden of each patient was assessed, combining tumour size of each involved region and number of regions involved. Tumour burden thus assessed proved to be the single most important prognostic factor with regard to disease free survival....... Other known prognostic factors such as number of involved regions, mediastinal size, pathological stage, systemic symptoms, and ESR were related to tumour burden and lost their prognostic significance in a multivariate analysis. The only other factors of independent significance were histologic subtype...

  19. A clinical case of single-stage correction of penetration combined orofacial defect with two microsurgical autografts

    Directory of Open Access Journals (Sweden)

    A. D. Kaprin

    2015-01-01

    Full Text Available After surgical treatment for locally advanced oral tumors with resection of soft tissues, mucosal membrane, and facial skeletal structures, there are penetration combined defects, removal of which is a challenge for reconstructive surgeons. Mandibular repair is one of the problems in the correction of combined oral defects. Surgeons use different grafts to remove mandibular defects. One-flap transplantation does not always solve all reconstruction problems and ensure the repair of the mucosal membrane, a soft-tissue component, skin integuments, and facial skeleton.The authors describe a clinical case of successful single-stage correction of penetration combined orofacial defect after resection of the tongue, mouth floor, en bloc resection of the lower jaw and mental soft tissues, bilateral cervical supramyochoroidal lymphadenectomy, stage LCL CM mandibular defect formation after J. Boyd, by using two microsurgical autografts (a peroneal skin-muscle-skin autograft and a radial skin-fascia one in a 39-year-old female patient clinically diagnosed with carcinoma of the left mandibular alveolar ridge mucosa, Stage IVA (T4аN0M0.The Department of Microsurgery, P.A. Herzen Moscow Oncology Research Institute, Ministry of Health of Russia, has gained experience in comprehensively correcting extensive combined maxillofacial defects with two or more grafts in 27 patients who underwent autografting with a total of 73 flaps. The most functionally incapacitating and life-incompatible defect was removed at Stage 1 of reconstructive treatment. Delayed reconstruction was made after a complex of specialized antitumor therapy and assessment of treatment results in the absence of progressive growth. A great problem during multi-stage defect correction is presented by the lack of recipient vessels after cervical lymphadenectomy, the presence of soft tissue scar changes, trismus, temporomandibular joint ankylosis, contractures and displacement of the edges of the

  20. Beam transport through electrostatic accelerators and matching into post accelerators

    International Nuclear Information System (INIS)

    Larson, J.D.

    1986-01-01

    Ion beam transport through electrostatic acceleration is briefly reviewed. Topics discussed include injection, matching into the low-energy acceleration stage, matching from the terminal stripper into the high-energy stage, transport to a post accelerator, space charge, bunching isochronism, dispersion and charge selection. Beam transport plans for the proposed Vivitron accelerator are described. (orig.)

  1. Single-shot measurements of low emittance beams from laser-plasma accelerators comparing two triggered injection methods

    Science.gov (United States)

    van Tilborg, Jeroen

    2017-10-01

    The success of laser plasma accelerator (LPA) based applications, such as a compact x-ray free electron laser (FEL), relies on the ability to produce electron beams with excellent 6D brightness, where brightness is defined as the ratio of charge to the product of the three normalized emittances. As such, parametric studies of the emittance of LPA generated electron beams are essential. Profiting from a stable and tunable LPA setup, combined with a carefully designed single-shot energy-dispersed emittance diagnostic, we present a direct comparison of charge dependent emittance measurements of electron beams generated by two different injection mechanisms: ionization injection and shock-induced density down-ramp injection. Both injection mechanisms have gained in popularity in recent years due to their demonstrated stable LPA performance. For the down-ramp injection configuration, normalized emittances a factor of two lower were recorded: less than 1 micron at spectral charge densities up to 2 pC/MeV. For both injection mechanisms, a contributing correlation of space charge to the emittance was identified. This measurement technique in general, and these results specifically, are critical to the evaluation of LPA injection methods and development of high-quality LPA beam lines worldwide. This work is supported by the U.S. DOE under Contract No. DE-AC02-05CH11231, by the U.S. DOE NNSA, DNN R&D (NA22), by the National Science Foundation under Grant No. PHY-1415596, and by the Gordon and Betty Moore Foundation under Grant ID GBMF4898.

  2. Epidemiology of end-stage renal disease in Dubai: Single-center data

    Directory of Open Access Journals (Sweden)

    Fakhriya Alalawi

    2017-01-01

    Full Text Available Hemodialysis (HD was first established in Dubai in the year 1980 and was in its full capacity by the year 1983. Since then, the HD population has been growing rapidly. This report represents the demographic data and clinical characteristics of our HD patients during the period between January 2012 and October 2016. Diabetic nephropathy (57% and hypertension (12.4% are emerging as the most common causes of end-stage renal disease (ESRD in our data, followed by undetermined causes in those who presented as ESRD (10.9%, and then by rejected transplant in 4.6%. Obstructive uropathy in our data was 4.37% among all causes. The causes were primary glomerulonephritis (only proven cases in kidney biopsy were counted in 3.6%, adult polycystic kidney disease in 2.43%, and lupus nephritis in 1.45% of cases. The prevalence of ESRD in the current study was 152 patients per million population per year.

  3. Single-stage quintuplet for upgrading triplet based lens system: Simulation for Atomki microprobe

    Science.gov (United States)

    Ponomarov, Artem; Rajta, Istvan; Nagy, Gyula; Romanenko, Oleksandr V.

    2017-08-01

    Among different configurations of lens systems for nuclear microprobes, the most common one is a triplet of magnetic quadrupole lenses. Nowadays, microanalysis and material modification will undoubtedly benefit from an improvement in spatial resolution. This work presents the results of simulations for improvement of the Oxford Triplet lens system at the Atomki microprobe with consideration of its system parameters and measured beam brightness distribution. For this purpose, an additional single-unit doublet of lenses with two power supplies was introduced. Using earlier developed methods, such a quintuplet system was optimized in order to determine the parameters which provided the highest resolution for different current operational modes with the same microprobe geometry. The tolerances for lens positioning accuracy were also calculated. The obtained quintuplet parameters indicate a resolution improvement for the Atomki microprobe compared to the Oxford Triplet system and these results validate further experimental testing of the proposed quintuplet.

  4. Single-Cell Analysis Identifies Distinct Stages of Human Endothelial-to-Hematopoietic Transition

    Directory of Open Access Journals (Sweden)

    Carolina Guibentif

    2017-04-01

    Full Text Available During development, hematopoietic cells originate from endothelium in a process known as endothelial-to-hematopoietic transition (EHT. To study human EHT, we coupled flow cytometry and single-cell transcriptional analyses of human pluripotent stem cell-derived CD34+ cells. The resulting transcriptional hierarchy showed a continuum of endothelial and hematopoietic signatures. At the interface of these two signatures, a unique group of cells displayed both an endothelial signature and high levels of key hematopoietic stem cell-associated genes. This interphase group was validated via sort and subculture as an immediate precursor to hematopoietic cells. Differential expression analyses further divided this population into subgroups, which, upon subculture, showed distinct hematopoietic lineage differentiation potentials. We therefore propose that immediate precursors to hematopoietic cells already have their hematopoietic lineage restrictions defined prior to complete downregulation of the endothelial signature. These findings increase our understanding of the processes of de novo hematopoietic cell generation in the human developmental context.

  5. A Collaborative Analysis Tool for Integrating Hypersonic Aerodynamics, Thermal Protection Systems, and RBCC Engine Performance for Single Stage to Orbit Vehicles

    Science.gov (United States)

    Stanley, Thomas Troy; Alexander, Reginald

    1999-01-01

    Presented is a computer-based tool that connects several disciplines that are needed in the complex and integrated design of high performance reusable single stage to orbit (SSTO) vehicles. Every system is linked to every other system, as is the case of SSTO vehicles with air breathing propulsion, which is currently being studied by NASA. The deficiencies in the scramjet powered concept led to a revival of interest in Rocket-Based Combined-Cycle (RBCC) propulsion systems. An RBCC propulsion system integrates airbreathing and rocket propulsion into a single engine assembly enclosed within a cowl or duct. A typical RBCC propulsion system operates as a ducted rocket up to approximately Mach 3. At this point the transitions to a ramjet mode for supersonic-to-hypersonic acceleration. Around Mach 8 the engine transitions to a scram4jet mode. During the ramjet and scramjet modes, the integral rockets operate as fuel injectors. Around Mach 10-12 (the actual value depends on vehicle and mission requirements), the inlet is physically closed and the engine transitions to an integral rocket mode for orbit insertion. A common feature of RBCC propelled vehicles is the high degree of integration between the propulsion system and airframe. At high speeds the vehicle forebody is fundamentally part of the engine inlet, providing a compression surface for air flowing into the engine. The compressed air is mixed with fuel and burned. The combusted mixture must be expanded to an area larger than the incoming stream to provide thrust. Since a conventional nozzle would be too large, the entire lower after body of the vehicle is used as an expansion surface. Because of the high external temperatures seen during atmospheric flight, the design of an airbreathing SSTO vehicle requires delicate tradeoffs between engine design, vehicle shape, and thermal protection system (TPS) sizing in order to produce an optimum system in terms of weight (and cost) and maximum performance.

  6. Single stage reconstruction of ruptured tendoachilles tendon with skin cover using distally based superficial sural artery flap.

    Science.gov (United States)

    Abhyankar, Suhas V; Kulkarni, Ananta; Agarwal, Naveen Kumar

    2009-10-01

    Ruptured tendoachilles along with skin defect is a complex problem to reconstruct. Both things require a priority. Single stage reconstruction of ruptured tendoachilles tendon with skin cover using distally based superficial sural arterial flap allows us to perform both. This procedure gives excellent result, shortens the stay, thereby reducing the cost. This method is a simple solution to the complex problem like ruptured tendoachilles with skin defect. In this study, 6 patients with rupture of tendoachilles tendon due to penetrating injury, with skin defect are presented. The repair was done using aponeurotic part of tendoachilles tendon, taken from proximal part of tendoachilles in the midline measuring around 2 to 2.5 cm in width and 8 to 10 cm in length, with intact distal attachment. The tendon was turned upside down by 180 degrees and sutured to the distal stump of the tendoachilles tendon without tension. The skin defect was covered using distally based superficial sural artery flap in the same sitting. The follow-up period was 9 to 30 months. All patients showed good results. In one patient there was distal necrosis of 1.5 cm of the distally based superficial sural artery flap, which healed satisfactorily with conservative treatment. Single stage tendoachilles reconstruction can be used with good functional result and patient satisfaction.

  7. Single-virus tracking approach to reveal the interaction of Dengue virus with autophagy during the early stage of infection

    Science.gov (United States)

    Chu, Li-Wei; Huang, Yi-Lung; Lee, Jin-Hui; Huang, Long-Ying; Chen, Wei-Jun; Lin, Ya-Hsuan; Chen, Jyun-Yu; Xiang, Rui; Lee, Chau-Hwang; Ping, Yueh-Hsin

    2014-01-01

    Dengue virus (DENV) is one of the major infectious pathogens worldwide. DENV infection is a highly dynamic process. Currently, no antiviral drug is available for treating DENV-induced diseases since little is known regarding how the virus interacts with host cells during infection. Advanced molecular imaging technologies are powerful tools to understand the dynamics of intracellular interactions and molecular trafficking. This study exploited a single-virus particle tracking technology to address whether DENV interacts with autophagy machinery during the early stage of infection. Using confocal microscopy and three-dimensional image analysis, we showed that DENV triggered the formation of green fluorescence protein-fused microtubule-associated protein 1A/1B-light chain 3 (GFP-LC3) puncta, and DENV-induced autophagosomes engulfed DENV particles within 15-min postinfection. Moreover, single-virus particle tracking revealed that both DENV particles and autophagosomes traveled together during the viral infection. Finally, in the presence of autophagy suppressor 3-methyladenine, the replication of DENV was inhibited and the location of DENV particles spread in cytoplasma. In contrast, the numbers of newly synthesized DENV were elevated and the co-localization of DENV particles and autophagosomes was detected while the cells were treated with autophagy inducer rapamycin. Taken together, we propose that DENV particles interact with autophagosomes at the early stage of viral infection, which promotes the replication of DENV.

  8. A single centre experience with sequential and concomitant chemoradiotherapy in locally advanced stage IV tonsillar cancer

    Directory of Open Access Journals (Sweden)

    Coyle Catherine

    2010-12-01

    Full Text Available Abstract Background Chemo-radiotherapy offers an alternative to primary surgery and adjuvant therapy for the management of locally advanced stage IV squamous cell carcinomas of the tonsil. Methods A retrospective analysis was performed of the outcomes of 41 patients with locoregionally advanced squamous cell carcinoma of the tonsil treated non-surgically at the Yorkshire Cancer Centre between January 2004 and December 2005. Due to long radiotherapy waiting times, patients received induction chemotherapy with cisplatin and 5-fluorouracil followed by either cisplatin concurrent chemoradiotherapy or radiotherapy alone. Results Median age was 55 years (range 34-76 years and 28 (68% patients were male. 35/41 patients (85% received 2 or more cycles of induction chemotherapy. Following induction chemotherapy, 32/41 patients (78% had a clinical response. Concomitant chemotherapy was given to 30/41 (73%. All patients received the planned radiotherapy dose with no delays. There were no treatment related deaths. Six (15% patients had gastrostomy tubes placed before treatment, and 22 (54% required nasogastric tube placement during or after treatment for nutritional support. 17 patients required unplanned admissions during treatment for supportive care. At 4 months post treatment assessment 35 out of 41 (85% patients achieved complete clinical and radiographic response. Median follow-up is 38 months (8-61 months. Local and regional control rate in complete responders at 3 years was 91%. Distant metastases have been found in 4 (9.8% patients. Three year progression-free survival rate in all patients is 75%. The 3-year cause specific survival and overall survival are 75% and 66% respectively. Conclusion Cisplatin-based induction and concurrent chemoradiotherapy provides excellent tumour control with acceptable toxicity for patients with locally advanced tonsillar cancer.

  9. A single centre experience with sequential and concomitant chemoradiotherapy in locally advanced stage IV tonsillar cancer

    International Nuclear Information System (INIS)

    D Prestwich, Robin J; Kancherla, Kiran; Oksuz, Didem Colpan; Williamson, Deborah; Dyker, Karen E; Coyle, Catherine; Sen, Mehmet

    2010-01-01

    Chemo-radiotherapy offers an alternative to primary surgery and adjuvant therapy for the management of locally advanced stage IV squamous cell carcinomas of the tonsil. A retrospective analysis was performed of the outcomes of 41 patients with locoregionally advanced squamous cell carcinoma of the tonsil treated non-surgically at the Yorkshire Cancer Centre between January 2004 and December 2005. Due to long radiotherapy waiting times, patients received induction chemotherapy with cisplatin and 5-fluorouracil followed by either cisplatin concurrent chemoradiotherapy or radiotherapy alone. Median age was 55 years (range 34-76 years) and 28 (68%) patients were male. 35/41 patients (85%) received 2 or more cycles of induction chemotherapy. Following induction chemotherapy, 32/41 patients (78%) had a clinical response. Concomitant chemotherapy was given to 30/41 (73%). All patients received the planned radiotherapy dose with no delays. There were no treatment related deaths. Six (15%) patients had gastrostomy tubes placed before treatment, and 22 (54%) required nasogastric tube placement during or after treatment for nutritional support. 17 patients required unplanned admissions during treatment for supportive care. At 4 months post treatment assessment 35 out of 41 (85%) patients achieved complete clinical and radiographic response. Median follow-up is 38 months (8-61 months). Local and regional control rate in complete responders at 3 years was 91%. Distant metastases have been found in 4 (9.8%) patients. Three year progression-free survival rate in all patients is 75%. The 3-year cause specific survival and overall survival are 75% and 66% respectively. Cisplatin-based induction and concurrent chemoradiotherapy provides excellent tumour control with acceptable toxicity for patients with locally advanced tonsillar cancer

  10. Endoscopic mucosal resection for staging and treatment of early esophageal carcinoma: a single institution experience.

    Science.gov (United States)

    Huntington, Justin T; Walker, Jon P; Meara, Michael P; Hazey, Jeffrey W; Melvin, W Scott; Perry, Kyle A

    2015-08-01

    Endoscopic mucosal resection (EMR) has emerged for evaluation and treatment of esophageal nodules. We report our initial experience with EMR for T staging and management of early esophageal cancer. We reviewed patients undergoing EMR for esophageal adenocarcinoma between 2008 and 2013. The primary outcome measure was needed for esophagectomy. Secondary outcomes included complete eradication of adenocarcinoma, recurrence or persistence of cancer, nodal status for those undergoing esophagectomy, and complications of endoscopic treatment. During the study period, 24 patients underwent EMR demonstrating carcinoma, and a grossly margin negative endoscopic resection was achieved in all cases. Ten patients (42 %) had evidence of submucosal invasion and were referred for esophagectomy. Patients with margin negative EMR (n = 10, 42 %) or positive radial margins (n = 4, 16 %) underwent endoscopic surveillance and treatment with radiofrequency ablation or repeat EMR as needed. Thirteen patients (93 %) with intramucosal cancer (IMC) have been successfully managed with ongoing endoscopic surveillance and treatment with a median follow-up of 15.5 months. One patient underwent esophagectomy due to recurrent IMC in the setting of long-segment multifocal high-grade dysplasia. There were no esophageal perforations, one patient developed a self-limited gastrointestinal hemorrhage following EMR, and one had an esophageal stricture following endoscopic management. IMC can be successfully managed endoscopically and thus esophagectomy is avoided in a significant proportion of patients. Endoscopic management may be utilized in the setting of complete resection or radial margin involvement without evidence of submucosal invasion. Close endoscopic follow-up is of paramount importance even in those with negative margins, because recurrent disease may occur following EMR in these patients.

  11. Exergy analysis of an experimental single-stage heat transformer operating with single water/lithium bromide and using additives (1-octanol and 2-ethyl-1-hexanol)

    International Nuclear Information System (INIS)

    Rivera, W.; Martinez, H.; Cerezo, J.; Romero, R.J.; Cardoso, M.J.

    2011-01-01

    Second law of Thermodynamics has been used to analyze the performance of an experimental single-stage heat transformer operating with the water/lithium bromide as single working pair and subsequently, using 1-octanol and 2-ethyl-1-hexanol as additives. Additives have been used in order to increase the heat transfer in the absorber and generator decreasing their irreversibilities. The enthalpy-based coefficients of performance (COP), external coefficients of performance (COP EXT ), exergy-based coefficients of performance (ECOP) and the irreversibilities of the equipment components were calculated for the main operating temperatures of the system. The results showed that for absorber temperatures between 84 o C and 88 o C the highest COP, COP EXT , and ECOP are obtained with the use of the 2-ethyl-1-hexanol (400 parts per million) additive, reaching values up to 0.49, 0.40 and 0.43, respectively. The lowest coefficients of performance and highest irreversibilities were obtained by using the single water/lithium bromide mixture. Analysing the irreversibilities in each one of the main components of the system, it was found that 2-ethyl-1-hexanol decreases considerably the irreversibility in the absorber then increasing the efficiency of this component and hence of the entire equipment. - Highlights: → An exergy analysis has been used to analyze an experimental heat transformer. → The system operated with single water/lithium bromide and then adding two additives. → The additives were 1-octanol and 2-ethyl-1-hexanol. → The 2-ethyl-1-hexanol additive reduced the system irreversibilities. → The highest coefficients of performance were obtained with the 2-ethyl-1-hexanol additive.

  12. Transverse preputial onlay island flap urethroplasty for single-stage correction of proximal hypospadias.

    Science.gov (United States)

    Singal, Arbinder Kumar; Dubey, Manish; Jain, Viral

    2016-07-01

    Transverse preputial onlay island flap urethroplasty (TPOIF) was described initially for distal hypospadias, but has seen extended application for proximal hypospadias. We describe a set of modifications in the technique and results in a large series of proximal hypospadias. All children who underwent TPOIF repair for proximal hypospadias (proximal penile, penoscrotal and scrotal) from June 2006 to June 2013 by a single surgeon were prospectively followed till June, 2014. A standard technique and postoperative protocol were followed. Salient points to be emphasized in the technique: (1) dissection of the dartos pedicle till penopubic junction to prevent penile torsion, (2) incorporation of the spongiosum in the urethroplasty, (3) midline urethral plate incision in glans (hinging the plate), (4) Dartos blanket cover on whole urethroplasty. Out of 136 children with proximal hypospadias, 92 children who underwent TPOIF formed the study group. Out of 92 children, 48 (52 %) children required a tunica albuginea plication for chordee correction. In total, 16 (17 %) patients developed 24 complications and 11 children (12 %) required second surgeries: fistula closure in 7 (with meatoplasty in 5), glansplasty for glans dehiscence in 2 and excision of diverticulum in 2. Two children required a third surgery. Only 5 children had a noticeable penile torsion (less than 30 degree), and 7 had a patulous meatus. Transverse preputial onlay island flap urethroplasty can deliver reliable cosmetic and functional outcomes in proximal hypospadias.

  13. Advanced exergy analysis applied to a single-stage heat transformer

    International Nuclear Information System (INIS)

    Colorado, D.

    2017-01-01

    Highlights: • Endogenous, exogenous, avoidable and unavoidable exergy destruction was calculated for a heat transformer. • 14.78% of the total exergy destruction could be reduced assuming improvements in the efficiency and design of the equipment. • A parametric study was discussed considering variations in the operation conditions. - Abstract: This study presents an advanced exergy analysis of a single-state absorption heat transformer operating with a lithium bromide water solution. A traditional exergy analysis was also conducted to identify the components with the highest contribution to the exergy destruction, and an advanced exergy approach was developed to estimate a realistic design and improve the operating conditions of the system. According to the base case of this study, when calculating the total reversibility of the cycle, only 14.78% could be reduced by improving its design and configuration. In addition, a parametric study was presented to discuss the sensitivity of splitting exergy destruction concepts taking into account temperature variations in the heat source, sink, and seawater outlet. Considering improvements to the generator a top priority, followed by improving the absorber, the condenser and finally the evaporator. The numerical results of this work have been developed to help design engineers experiment and assemble future equipment.

  14. Acute Toxicity Profile and Compliance to Accelerated Radiotherapy Plus Carbogen and Nicotinamide for Clinical Stage T2-4 Laryngeal Cancer: Results of a Phase III Randomized Trial

    Energy Technology Data Exchange (ETDEWEB)

    Janssens, Geert O., E-mail: g.janssens@rther.umcn.nl [Department of Radiation Oncology, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands); Terhaard, Chris H. [Department of Radiation Oncology, University Medical Center Utrecht, Utrecht (Netherlands); Doornaert, Patricia A. [Department of Radiation Oncology, VU University Medical Center, Amsterdam (Netherlands); Bijl, Hendrik P. [Department of Radiation Oncology, University Medical Center Groningen, Groningen (Netherlands); Ende, Piet van den [Department of Radiation Oncology, Maastricht University Medical Centre, Maastricht (Netherlands); Chin, Alim [Department of Clinical Oncology, Leiden University Medical Centre, Leiden (Netherlands); Pop, Lucas A.; Kaanders, Johannes H. [Department of Radiation Oncology, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands)

    2012-02-01

    Purpose: To report the acute toxicity profile and compliance from a randomized Phase III trial comparing accelerated radiotherapy (AR) with accelerated radiotherapy plus carbogen and nicotinamide (ARCON) in laryngeal cancer. Methods and Materials: From April 2001 to February 2008, 345 patients with cT2-4 squamous cell laryngeal cancer were randomized to AR (n = 174) and ARCON (n = 171). Acute toxicity was scored weekly until Week 8 and every 2-4 weeks thereafter. Compliance to carbogen and nicotinamide was reported. Results: Between both treatment arms (AR vs. ARCON) no statistically significant difference was observed for incidence of acute skin reactions (moist desquamation: 56% vs. 58%, p = 0.80), acute mucosal reactions (confluent mucositis: 79% vs. 85%, p = 0.14), and symptoms related to acute mucositis (severe pain on swallowing: 53% vs. 58%, p = 0.37; nasogastric tube feeding: 28% vs. 28%, p = 0.98; narcotic medicines required: 58% vs. 58%, p = 0.97). There was a statistically significant difference in median duration of confluent mucositis in favor of AR (2.0 vs 3.0 weeks, p = 0.01). There was full compliance with carbogen breathing and nicotinamide in 86% and 80% of the patients, with discontinuation in 6% and 12%, respectively. Adjustment of antiemesis prophylaxis was needed in 42% of patients. Conclusion: With the exception of a slight increase in median duration of acute confluent mucositis, the present data reveal a similar acute toxicity profile between both regimens and a good compliance with ARCON for clinical stage T2-4 laryngeal cancers. Treatment outcome and late morbidity will determine the real therapeutic benefit.

  15. Robotic-Assisted Transperitoneal Aortic Lymphadenectomy as Part of Staging Procedure for Gynaecological Malignancies: Single Institution Experience

    Directory of Open Access Journals (Sweden)

    V. Zanagnolo

    2013-01-01

    Full Text Available Introduction. This study was designed to confirm the feasibility and safety of robotic-assisted transperitoneal aortic lymphadenectomy as part of staging procedure for gynecologic malignancies. Methods. Chart review of 51 patients who had undergone robotic staging with aortic lymphadenectomy for different gynaecologic malignancies was performed. Results. The primary diagnosis was as follows: 6 cases of endometrial cancer, 31 epithelial ovarian cancer, 9 nonepithelial ovarian cancer, 4 tubal cancer, and 1 cervical cancer. Median BMI was 23 kg/m2. Except for a single case of aortic lymphadenectomy only, both aortic and pelvic lymphadenectomies were performed at the time of the staging procedure. All the para-aortic lymphadenectomies were carried out to the level of the renal veinl but 6 cases were carried out to the level of the inferior mesenteric artery. Hysterectomy was performed in 24 patiens (47%. There was no conversion to LPT. The median console time was 285 (range 195–402 with a significant difference between patients who underwent hysterectomy and those who did not. The median estimated blood loss was 50 mL (range 20–200. The mean number of removed nodes was 29±9.6. The mean number of pelvic nodes was 15±7.6, whereas the mean number of para-aortic nodes was 14±6.6. Conclusions. Robotic transperitoneal infrarenal aortic lymphadenectomy as part of staging procedure is feasible and can be safely performed. Additional trocars are needed when pelvic surgery is also performed.

  16. Fractional Models Simulating Non-Fickian Behavior in Four-Stage Single-Well Push-Pull Tests

    Science.gov (United States)

    Chen, Kewei; Zhan, Hongbin; Yang, Qiang

    2017-11-01

    Four-stage single-well push-pull (SWPP) tracer tests, including injection, chasing, resting, and pumping, were conducted in a fractured aquifer at Newark basin. An anomalous transport phenomenon observed in the SWPP tests is the linear decline of breakthrough curves (BTCs) at late time with slope of -1.8 in log-log plots. A time-dependent fractional model is developed to interpret the anomalous transport behavior. This model considers a time-dependent power law memory function and a time-dependent fractional advection-dispersion operator. The fractional advection-dispersion equations (fADE) are solved in a radial coordinate system using the implicit Euler method. A semi-analytical solution of the first-order rate-limited mobile-immobile model (FORMIM) is derived for comparison. It is found that both the nonlocal transport in time and space can produce the long-tailed BTC. A smaller time-fractional or space-fractional index leads to a lower peak concentration and a larger late-time slope. The mass distribution of the fractional-in-space (FS) model exhibits power law decline at the leading plume edge. Early breakthrough during pumping is not observed because the mobile mass at the start of pumping is nonzero and more concentrated near the wellbore. The capacity ratio is an important factor that affects the peak concentration. A larger capacity ratio leads to greater peak concentration. A smaller time-fractional index in the injection, chasing, or resting stage will move the BTC downward and the slope of the late time BTC is determined by the space-fractional index over all stages and the time-fractional index in the pumping stage. The capability of the existing models to recover the BTC of the SWPP test is discussed and some guidelines for how to choose the appropriate model to interpret the SWPP test data are proposed.

  17. Sorting of cells of the same size, shape, and cell cycle stage for a single cell level assay without staining

    Directory of Open Access Journals (Sweden)

    Yomo Tetsuya

    2006-06-01

    Full Text Available Abstract Background Single-cell level studies are being used increasingly to measure cell properties not directly observable in a cell population. High-performance data acquisition systems for such studies have, by necessity, developed in synchrony. However, improvements in sample purification techniques are also required to reveal new phenomena. Here we assessed a cell sorter as a sample-pretreatment tool for a single-cell level assay. A cell sorter is routinely used for selecting one type of cells from a heterogeneous mixture of cells using specific fluorescence labels. In this case, we wanted to select cells of exactly the same size, shape, and cell-cycle stage from a population, without using a specific fluorescence label. Results We used four light scatter parameters: the peak height and area of the forward scatter (FSheight and FSarea and side scatter (SSheight and SSarea. The rat pheochromocytoma PC12 cell line, a neuronal cell line, was used for all experiments. The living cells concentrated in the high FSarea and middle SSheight/SSarea fractions. Single cells without cell clumps were concentrated in the low SS and middle FS fractions, and in the higher FSheight/FSarea and SSheight/SSarea fractions. The cell populations from these viable, single-cell-rich fractions were divided into twelve subfractions based on their FSarea-SSarea profiles, for more detailed analysis. We found that SSarea was proportional to the cell volume and the FSarea correlated with cell roundness and elongation, as well as with the level of DNA in the cell. To test the method and to characterize the basic properties of the isolated single cells, sorted cells were cultured in separate wells. The cells in all subfractions survived, proliferated and differentiated normally, suggesting that there was no serious damage. The smallest, roundest, and smoothest cells had the highest viability. There was no correlation between proliferation and differentiation. NGF increases

  18. Low Energy Multi-Stage Atrial Defibrillation Therapy Terminates Atrial Fibrillation with Less Energy than a Single Shock

    Science.gov (United States)

    Li, Wenwen; Janardhan, Ajit H.; Fedorov, Vadim V.; Sha, Qun; Schuessler, Richard B.; Efimov, Igor R.

    2011-01-01

    Background Implantable device therapy of atrial fibrillation (AF) is limited by pain from high-energy shocks. We developed a low-energy multi-stage defibrillation therapy and tested it in a canine model of AF. Methods and Results AF was induced by burst pacing during vagus nerve stimulation. Our novel defibrillation therapy consisted of three stages: ST1 (1-4 low energy biphasic shocks), ST2 (6-10 ultra-low energy monophasic shocks), and ST3 (anti-tachycardia pacing). Firstly, ST1 testing compared single or multiple monophasic (MP) and biphasic (BP) shocks. Secondly, several multi-stage therapies were tested: ST1 versus ST1+ST3 versus ST1+ST2+ST3. Thirdly, three shock vectors were compared: superior vena cava to distal coronary sinus (SVC>CSd), proximal coronary sinus to left atrial appendage (CSp>LAA) and right atrial appendage to left atrial appendage (RAA>LAA). The atrial defibrillation threshold (DFT) of 1BP shock was less than 1MP shock (0.55 ± 0.1 versus 1.38 ± 0.31 J; p =0.003). 2-3 BP shocks terminated AF with lower peak voltage than 1BP or 1MP shock and with lower atrial DFT than 4 BP shocks. Compared to ST1 therapy alone, ST1+ST3 lowered the atrial DFT moderately (0.51 ± 0.46 versus 0.95 ± 0.32 J; p = 0.036) while a three-stage therapy, ST1+ST2+ST3, dramatically lowered the atrial DFT (0.19 ± 0.12 J versus 0.95 ± 0.32 J for ST1 alone, p=0.0012). Finally, the three-stage therapy ST1+ST2+ST3 was equally effective for all studied vectors. Conclusions Three-stage electrotherapy significantly reduces the AF defibrillation threshold and opens the door to low energy atrial defibrillation at or below the pain threshold. PMID:21980076

  19. Single stage bilateral uniportal videothoracoscopic sympathicotomy for hyperhidrosis: can it be managed as an outpatient procedure?

    Directory of Open Access Journals (Sweden)

    Ahmet Demirkaya

    2016-05-01

    Full Text Available Introduction : The videothoracoscopic approach is minimally invasive with benefits that include less postoperative pain and shorter hospital stay. It is also a safe procedure which can be performed on an outpatient basis. Aim: To determine whether videothoracoscopic sympathicotomy can be performed safely in most patients as an outpatient procedure. Material and methods: Between July 2005 and October 2015, a total of 92 patients underwent bilateral and single port thoracoscopic sympathicotomy in our department on an outpatient basis. The level of sympathicotomy was T2 in 2 (2.2% patients, T2 to T3 in 31 (33% patients, T2 to T4 in 46 (50% patients and T3 to T4 in 12 (13% patients. Demographic data, length of postoperative stay, substitution index (SI, admission rate (AR and readmission rate (RR, complications and patient satisfaction were reviewed retrospectively. Results: Two (2.2% patients suffered from chest pain, while 4 (4.3% patients complained about pain at the port site. Mean discharge time after surgery was 5.1 h (range: 4–6 h, mean duration of hospital stay was 0.15 days (0–3 days postoperatively and the mean operation time was 43.6 min (15–130 min. In 8 (8.6% patients, pneumothorax was detected on postoperative chest X-ray, while 5 (5.4% patients required chest tube drainage. Mild or moderate compensatory sweating developed in 32 (34.7% patients. No recurrence was observed, and the satisfaction rate was 96.7%. Substitution index and admission rate were 91.3% and 11% respectively, while RR was 0%. Conclusions : Bilateral video-assisted thoracoscopic sympathicotomy can be performed safely in most patients as an outpatient procedure.

  20. Results of single-staged rotational osteotomy in a child with congenital proximal radioulnar synostosis: subjective and objective evaluation.

    Science.gov (United States)

    Shingade, Viraj U; Shingade, Rashmi V; Ughade, Suresh N

    2014-01-01

    For congenital proximal radioulnar synostosis, both conservative and operative treatments have been described. Most of the studies describing surgical interventions are based on subjective evaluation of the forearm function and have used severe degree of forearm pronation as an indication for surgery. This study describes a single-staged rotational osteotomy of the proximal third ulna and distal third radius. The aim of the study was to assess the utility of the described surgical procedure by subjective and objective evaluations of the forearm function. Forty-eight children with congenital proximal radioulnar synostosis were evaluated by subjective and objective assessments and were followed up prospectively. Subjective evaluation consisted of a set of 12 questions regarding the basic activities of life. Objective evaluation was made using the Jebsen-Taylor hand-function test and a classification system used by Failla and colleagues for 15 tasks described by Morrey and colleagues. Eleven children were treated conservatively. Thirty-six children underwent a single-staged rotational osteotomy of the proximal third ulna and distal third radius. After surgery, the evaluations were repeated. The mean age at surgery was 8.6±3.7 years, and the mean postoperative follow-up period was 54±13 months. All operated forearms showed a statistically significant improvement in functioning after surgery as per the subjective and objective evaluations. The mean time taken to carry out all activities before surgery was 47.7+10.0 seconds, which significantly reduced to 33.3+6.6 seconds after surgery (P=0.0001) as per the results of the Jebsen-Taylor hand-function test. All good (n=19) and fair (n=11) results were converted to excellent (n=30) after surgery as per the modified Failla classification. There were no neurovascular injuries as compared with other published techniques. Only 1 child had delayed union, and 1 had persistent dorsal angulation at the radial osteotomy site. For

  1. A Rocket Powered Single-Stage-to-Orbit Launch Vehicle With U.S. and Soviet Engineers

    Science.gov (United States)

    MacConochie, Ian O.; Stnaley, Douglas O.

    1991-01-01

    A single-stage-to-orbit launch vehicle is used to assess the applicability of Soviet Energia high-pressure-hydrocarbon engine to advanced U.S. manned space transportation systems. Two of the Soviet engines are used with three Space Shuttle Main Engines. When applied to a baseline vehicle that utilized advanced hydrocarbon engines, the higher weight of the Soviet engines resulted in a 20 percent loss of payload capability and necessitated a change in the crew compartment size and location from mid-body to forebody in order to balance the vehicle. Various combinations of Soviet and Shuttle engines were evaluated for comparison purposes, including an all hydrogen system using all Space Shuttle Main Engines. Operational aspects of the baseline vehicle are also discussed. A new mass properties program entitles Weights and Moments of Inertia (WAMI) is used in the study.

  2. Advantages of using a two-switch forward in single-stage power factor corrected power supplies

    DEFF Research Database (Denmark)

    Petersen, Lars

    2000-01-01

    A single-stage power factor corrected power supply using a two-switch forward is proposed to increase efficiency. The converter is operated in the DCM (discontinues conduction mode) and it is shown that this operation mode ensures the intermediate DC-bus to be controlled only by means of circuit...... parameters and therefore independent of load variations. The DCM operation often has a diminishing effect on the efficiency but by use of the two-switch topology high efficiency with minimum circuit complexity can be achieved in this mode. A 500 W 70 V prototype of the two-switch boost-forward PFC power...... supply has been implemented. The measured efficiency is between 85% and 88.5% in the range 30 W-500 W and the measured power factor at full load is 0.95....

  3. Slip-band formation and dislocation kinetics in the stage I deformation of neutron-irradiated copper single crystals

    International Nuclear Information System (INIS)

    Kitajima, Sadakichi; Shinohara, Kazutoshi; Kutsuwada, Masanori

    1995-01-01

    The velocity of edge and screw dislocations moving in primary slip bands and the formation rate of primary slip bands were measured in stage I deformation of neutron-irradiated copper single crystals at different strain rates at room temperature using micro-cinematography and optical micrography. The average velocity of edge dislocations was larger at least by one order than that of screw ones, and that of screw dislocations did not depend so strongly on strain rate. The formation rate of primary slip bands was proportional to strain rate. From these results, it is concluded that (1) jogs produced on moving dislocations by cutting dislocation loops result in the difference in velocity between edge and screw dislocations and (2) the change in the density of mobile dislocations as well as velocity of dislocations is responsible for the change of plastic strain rate of a crystal. (author)

  4. Bilateral Simultaneous Revision Total Knee Arthroplasty as a Single Staged Procedure: A Case Report and Review of Literature.

    Science.gov (United States)

    Vaishya, Raju; Agarwal, Amit Kumar; Jaiswal, Chirag; Vijay, Vipul; Vaish, Abhishek

    2017-03-23

    Bilateral revision total knee arthroplasty (TKA) is a surgical procedure, which is rarely done simultaneously as it is a difficult surgery and the safety of simultaneous bilateral single stage surgery remains unknown. We report a case of a 67-year-old woman who presented to us with bilateral painful and unstable TKA (right > left) of six months duration. The primary bilateral TKA were done 14 years ago. Bilateral simultaneous revision TKA was performed, using cemented, constrained, long-stem prostheses. The intraoperative and postoperative periods remained uneventful. At last follow-up at four years, she had a pain-free range of motion of up to 0-115°, and the patient had returned to the activities of daily living. She had stable knees with good function and no evidence of loosening or wear.

  5. A rapid method for optimization of the rocket propulsion system for single-stage-to-orbit vehicles

    Science.gov (United States)

    Eldred, C. H.; Gordon, S. V.

    1976-01-01

    A rapid analytical method for the optimization of rocket propulsion systems is presented for a vertical take-off, horizontal landing, single-stage-to-orbit launch vehicle. This method utilizes trade-offs between propulsion characteristics affecting flight performance and engine system mass. The performance results from a point-mass trajectory optimization program are combined with a linearized sizing program to establish vehicle sizing trends caused by propulsion system variations. The linearized sizing technique was developed for the class of vehicle systems studied herein. The specific examples treated are the optimization of nozzle expansion ratio and lift-off thrust-to-weight ratio to achieve either minimum gross mass or minimum dry mass. Assumed propulsion system characteristics are high chamber pressure, liquid oxygen and liquid hydrogen propellants, conventional bell nozzles, and the same fixed nozzle expansion ratio for all engines on a vehicle.

  6. The Naso-labial and lateral forehead flaps as a single stage: A case report and review of literature

    Directory of Open Access Journals (Sweden)

    Adigun I

    2008-01-01

    Full Text Available We present here the case of a patient with a major traumatic nasal loses who had a near-total nasal reconstruction as a single-stage procedure. A 35 year-old civil servant who was involved in a road traffic injury about two years before presentation. He sustained extensive and multiple facial injuries with complete loss of nasal cover and lining. Reconstruction was performed by using superiorly based, bilateral, nasolabial flaps to line the floor and the nasal septum, and a paramedian forehead flap for skin cover. The patient did well postoperatively and was discharged home on the 7 th postoperative day. If the principles concerning cover, support, and lining are adhered to, excellent functional and aesthetic results can be achieved as we have obtained in our patient.

  7. Studies on water turbine runner which fish can pass through: In case of single stage axial runner

    International Nuclear Information System (INIS)

    Shimizu, Yukimari; Maeda, Takao; Nagoshi, Osamu; Ieda, Kazuma; Shinma, Hisako; Hagimoto, Michiko

    1994-01-01

    The relationship between water turbine runner design and operation and the safe passage of fish through the turbine is studied. The kinds of fish used in the tests are a dace, a sweet fish and a small salmon. A single stage axial runner is used. The velocity and pressure distributions were measured inside the turbine casing and along the casing wall. Many pictures showing fish passing through the rotating runner were taken and analyzed. The swimming speed of the fish was examined from video recordings. Fish pass through the runner more rapidly when they can determine and choose the easier path. Injury and mortality of fish are affected by the runner speed and the location of impact of the runner on the fish body

  8. Single stage concrete pumping through 2.432 km (1.51 miles: Weather and execution challenges

    Directory of Open Access Journals (Sweden)

    Chetan Hazaree

    2015-12-01

    Full Text Available This paper describes the execution challenges faced during single stage pumping of concrete through 2.432 km. Pump and pipeline selection and installation, materials’ development, establishing of control points and controlling variations are discussed. Concrete responses to weather changes play a vital role in concreting and pumping methodology development. Measuring pump pressure during pumping can provide insightful guidance to concreting. In order to optimize concrete mixtures, distance-specific mixture designs were developed and a relation between air-free paste volume (AFPV and pumping distance is derived. Pipeline priming and washout procedures specific to long-distance pumping are elaborated in detail. The paper presents a broad understanding regarding the challenges encountered; changes in pumping distance, materials, and climate would change the approach to solutions.

  9. Correlation Between the Microstructural Defects and Residual Stress in a Single Crystal Nickel-Based Superalloy During Different Creep Stages

    Science.gov (United States)

    Mo, Fangjie; Wu, Erdong; Zhang, Changsheng; Wang, Hong; Zhong, Zhengye; Zhang, Jian; Chen, Bo; Hofmann, Michael; Gan, Weimin; Sun, Guangai

    2018-03-01

    The present work attempts to reveal the correlation between the microstructural defects and residual stress in the single crystal nickel-based superalloy, both of which play the significant role on properties and performance. Neutron diffraction was employed to investigate the microstructural defects and residual stresses in a single crystal (SC) nickel-based superalloy, which was subjected to creeping under 220 MPa and 1000 °C for different times. The measured superlattice and fundamental lattice reflections confirm that the mismatch and tetragonal distortions with c/a > 1 exist in the SC superalloy. At the initially unstrained state, there exists the angular distortion between γ and γ' phases with small triaxial compressive stresses, ensuring the structural stability of the superalloy. After creeping, the tetragonal distortion for the γ phase is larger than that for the γ' phase. With increasing the creeping time, the mismatch between γ and γ' phases increases to the maximum, then decreases gradually and finally remains unchanged. The macroscopic residual stress shows a similar behavior with the mismatch, indicating the correlation between them. Based on the model of shear and dislocations, the evolution of microstructural defects and residual stress are reasonably explained. The effect of shear is dominant at the primary creep stage, which greatly enlarges the mismatch and the residual stress. The dislocations weaken the effect of shear for the further creep stage, resulting in the decrease of the mismatch and relaxation of the residual stress. Those findings add some helpful understanding into the microstructure-performance relationship in the SC nickel-based superalloy, which might provide the insight to materials design and applications.

  10. The MARVEL domain protein, Singles Bar, is required for progression past the pre-fusion complex stage of myoblast fusion.

    Science.gov (United States)

    Estrada, Beatriz; Maeland, Anne D; Gisselbrecht, Stephen S; Bloor, James W; Brown, Nicholas H; Michelson, Alan M

    2007-07-15

    Multinucleated myotubes develop by the sequential fusion of individual myoblasts. Using a convergence of genomic and classical genetic approaches, we have discovered a novel gene, singles bar (sing), that is essential for myoblast fusion. sing encodes a small multipass transmembrane protein containing a MARVEL domain, which is found in vertebrate proteins involved in processes such as tight junction formation and vesicle trafficking where--as in myoblast fusion--membrane apposition occurs. sing is expressed in both founder cells and fusion competent myoblasts preceding and during myoblast fusion. Examination of embryos injected with double-stranded sing RNA or embryos homozygous for ethane methyl sulfonate-induced sing alleles revealed an identical phenotype: replacement of multinucleated myofibers by groups of single, myosin-expressing myoblasts at a stage when formation of the mature muscle pattern is complete in wild-type embryos. Unfused sing mutant myoblasts form clusters, suggesting that early recognition and adhesion of these cells are unimpaired. To further investigate this phenotype, we undertook electron microscopic ultrastructural studies of fusing myoblasts in both sing and wild-type embryos. These experiments revealed that more sing mutant myoblasts than wild-type contain pre-fusion complexes, which are characterized by electron-dense vesicles paired on either side of the fusing plasma membranes. In contrast, embryos mutant for another muscle fusion gene, blown fuse (blow), have a normal number of such complexes. Together, these results lead to the hypothesis that sing acts at a step distinct from that of blow, and that sing is required on both founder cell and fusion-competent myoblast membranes to allow progression past the pre-fusion complex stage of myoblast fusion, possibly by mediating fusion of the electron-dense vesicles to the plasma membrane.

  11. Single-cell pulsed-field gel electrophoresis to detect the early stage of DNA fragmentation in human sperm nuclei.

    Directory of Open Access Journals (Sweden)

    Satoru Kaneko

    Full Text Available Single-cell pulsed-field gel electrophoresis (SCPFGE with dual electrode pairs was developed to detect the early stage of DNA fragmentation in human sperm. The motile sperm were purified by the commonly used density-gradient centrifugation technique and subsequent swim-up. The sperm were embedded in a thin film of agarose containing bovine trypsin (20 µg/mL and were then lysed. Prior to SCPFGE, proteolysis of DNA-binding components, such as protamine and the nuclear matrix was essential to separate the long chain fibers from the fibrous and granular fragments derived from a single nucleus. The overall electrophoretic profiles elucidated the course of DNA fragmentation. A few large fibrous fragments were observed at the beginning of the process, however, as the fragmentation advanced, the long chain fibers decreased and shortened, and, conversely, the granular fragments increased until finally almost all the DNA was shredded. Although the ejaculate contained sperm with heterogeneous stages, the purified motile sperm exhibited several dozens of uniformly elongated fibers arising from the tangled DNA at the origin, whereas a part of these fibers gave rise to fibrous fragments beyond the tip of the elongated fibers, and their numbers and sizes varied among the sperm. Conventional intra-cytoplasmic sperm injection (ICSI usually depends on intra-operative light microscopic observation to select a sperm for injection. The present results revealed that sperm motility could not give full assurance of DNA integrity. SCPFGE is likely to serve an important role in the preoperative differential diagnosis to determine the competence of the sperm population provided for injection.

  12. From a Single Presentation of Poetry Up to Its Stylized Stage Image in the Form of Theatre Performance

    Directory of Open Access Journals (Sweden)

    Podmaková Ú Dagmar

    2017-06-01

    Full Text Available In the 1940s the Drama Company of the Slovak National Theatre introduced four poetry productions, which demonstrated the stage potential of the symbiosis of verse and a music-accompanied recitation in an original stage design solution. The single presentation of poetry of Poézia revolúcie a boja [The Poetry of Revolution and Fight, 1945] directed by Ján Jamnický and Pásmo poézie Janka Jesenského [The Show of Poetry by Janko Jesenský, 1946] directed by Jozef Budský were the first independent attempts at staging selected poetry. Besides recitation, they were dominated by the visual sign, powerful music sometimes accompanied by the singing of individuals and a voice band, and distinctive lighting design. Botto’s Smrť Jánošíkova [The Death of Jánošík] and Sládkovič’s Marína (both in 1948 directed by Jozef Budský displayed all features of synthetic theatre, combining recitation, voice band singing, scenic and visual solutions, metaphor, originally composed music inspired by the folk song, dance, film screening, and meaningful lighting. Jozef Budský indirectly built on Czech theatre, particularly on E. F. Burian. Both masterpieces by the authors of Štúr’s generation (Ján Botto, Andrej Sládkovič aroused the interest of the expert public and the audience. It triggered arguments about excessive directorial intervention and insufficient ideological character, especially in the theatre form of Marína.

  13. Brain single-photon emission tomography with technetium-99m hexamethylpropylene amine oxime in adolscents with intial-stage schizophrenia

    International Nuclear Information System (INIS)

    Batista, J.F.; Galiano, M.C.; Torres, L.A.; Hernandez, M.C.; Sosa, F.; Perera, A.; Perez, M.

    1995-01-01

    The objective of this study was to search for regional cerebral blood flow (rCBF) abnormalities in adolescents with initial-stage schizophrenia by means of brain single-photon emission tomography (SPET) using technetium-99m hexamethylpropylene amine oxime (HMPAO). SPET studies were performed on a homogeneous sample of 15 carefully selected adolescents with a recent diagnosis of schizophrenia, and without previous electroconvulsive or antipsychotic drug treatment. Computed tomography (CT) and electro-encephalographic (EEG) studies were performed in all patients. Qualitative and semiquantitative analysis of 99m Tc-HMPAO SPET studies showed an impaired rCBF in 12 patients (80%). The most common pattern was a decreased uptake of 99m Tc-HMPAO in the frontal lobes, usually in the left hemisphere. Conventional and quantitative EEG was positive in 12 (80%) and 15 (100%) patients, respectively. CT findings were positive in two patients (13%). There was a high level of concordance between SPET and EEG results and between SPET and clinical features (P > 0.05). This study suggests that previously untreated patients in the first stages of schizophrenia present functional abnormalities that are revealed by brain SPET. (orig.)

  14. Brain single-photon emission tomography with technetium-99m hexamethylpropylene amine oxime in adolscents with intial-stage schizophrenia

    Energy Technology Data Exchange (ETDEWEB)

    Batista, J.F. [Centro de Investigaciones Clinicas, Ciudad Habana (Cuba); Galiano, M.C. [Clinica del Adolescente, Ciudad Habana (Cuba); Torres, L.A. [Centro de Investigaciones Clinicas, Ciudad Habana (Cuba); Hernandez, M.C. [Clinica del Adolescente, Ciudad Habana (Cuba); Sosa, F. [Centro de Investigaciones Clinicas, Ciudad Habana (Cuba); Perera, A. [Centro de Investigaciones Clinicas, Ciudad Habana (Cuba); Perez, M. [Centro de Investigaciones Clinicas, Ciudad Habana (Cuba)

    1995-11-01

    The objective of this study was to search for regional cerebral blood flow (rCBF) abnormalities in adolescents with initial-stage schizophrenia by means of brain single-photon emission tomography (SPET) using technetium-99m hexamethylpropylene amine oxime (HMPAO). SPET studies were performed on a homogeneous sample of 15 carefully selected adolescents with a recent diagnosis of schizophrenia, and without previous electroconvulsive or antipsychotic drug treatment. Computed tomography (CT) and electro-encephalographic (EEG) studies were performed in all patients. Qualitative and semiquantitative analysis of {sup 99m}Tc-HMPAO SPET studies showed an impaired rCBF in 12 patients (80%). The most common pattern was a decreased uptake of {sup 99m}Tc-HMPAO in the frontal lobes, usually in the left hemisphere. Conventional and quantitative EEG was positive in 12 (80%) and 15 (100%) patients, respectively. CT findings were positive in two patients (13%). There was a high level of concordance between SPET and EEG results and between SPET and clinical features (P > 0.05). This study suggests that previously untreated patients in the first stages of schizophrenia present functional abnormalities that are revealed by brain SPET. (orig.)

  15. Test-compatible confidence intervals for adaptive two-stage single-arm designs with binary endpoint.

    Science.gov (United States)

    Kunzmann, Kevin; Kieser, Meinhard

    2018-01-01

    Inference after two-stage single-arm designs with binary endpoint is challenging due to the nonunique ordering of the sampling space in multistage designs. We illustrate the problem of specifying test-compatible confidence intervals for designs with nonconstant second-stage sample size and present two approaches that guarantee confidence intervals consistent with the test decision. Firstly, we extend the well-known Clopper-Pearson approach of inverting a family of two-sided hypothesis tests from the group-sequential case to designs with fully adaptive sample size. Test compatibility is achieved by using a sample space ordering that is derived from a test-compatible estimator. The resulting confidence intervals tend to be conservative but assure the nominal coverage probability. In order to assess the possibility of further improving these confidence intervals, we pursue a direct optimization approach minimizing the mean width of the confidence intervals. While the latter approach produces more stable coverage probabilities, it is also slightly anti-conservative and yields only negligible improvements in mean width. We conclude that the Clopper-Pearson-type confidence intervals based on a test-compatible estimator are the best choice if the nominal coverage probability is not to be undershot and compatibility of test decision and confidence interval is to be preserved. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Treatment of metastatic uveal melanoma with adoptive transfer of tumour-infiltrating lymphocytes: a single-centre, two-stage, single-arm, phase 2 study.

    Science.gov (United States)

    Chandran, Smita S; Somerville, Robert P T; Yang, James C; Sherry, Richard M; Klebanoff, Christopher A; Goff, Stephanie L; Wunderlich, John R; Danforth, David N; Zlott, Daniel; Paria, Biman C; Sabesan, Arvind C; Srivastava, Abhishek K; Xi, Liqiang; Pham, Trinh H; Raffeld, Mark; White, Donald E; Toomey, Mary Ann; Rosenberg, Steven A; Kammula, Udai S

    2017-06-01

    Uveal melanoma is a rare tumour with no established treatments once metastases develop. Although a variety of immune-based therapies have shown efficacy in metastatic cutaneous melanoma, their use in ocular variants has been disappointing. Recently, adoptive T-cell therapy has shown salvage responses in multiple refractory solid tumours. Thus, we sought to determine if adoptive transfer of autologous tumour-infiltrating lymphocytes (TILs) could mediate regression of metastatic uveal melanoma. In this ongoing single-centre, two-stage, phase 2, single-arm trial, patients (aged ≥16 years) with histologically confirmed metastatic ocular melanoma were enrolled. Key eligibility criteria were an Eastern Cooperative Oncology Group performance status of 0 or 1, progressive metastatic disease, and adequate haematological, renal, and hepatic function. Metastasectomies were done to procure tumour tissue to generate autologous TIL cultures, which then underwent large scale ex-vivo expansion. Patients were treated with lymphodepleting conditioning chemotherapy (intravenous cyclophosphamide [60 mg/kg] daily for 2 days followed by fludarabine [25 mg/m 2 ] daily for 5 days, followed by a single intravenous infusion of autologous TILs and high-dose interleukin-2 [720 000 IU/kg] every 8 h). The primary endpoint was objective tumour response in evaluable patients per protocol using Response to Evaluation Criteria in Solid Tumors, version 1.0. An interim analysis of this trial is reported here. The trial is registered at ClinicalTrials.gov, number NCT01814046. From the completed first stage and ongoing expansion stage of this trial, a total of 21 consecutive patients with metastatic uveal melanoma were enrolled between June 7, 2013, and Sept 9, 2016, and received TIL therapy. Seven (35%, 95% CI 16-59) of 20 evaluable patients had objective tumour regression. Among the responders, six patients achieved a partial response, two of which are ongoing and have not reached maximum

  17. Intercommunications of indexes of speed and power qualities of sportsmen single combat on the stage of the specialized base preparation

    Directory of Open Access Journals (Sweden)

    A.O. Nykytenko

    2013-01-01

    Full Text Available The purpose of work is a study of interdependence between indexes specially-preparatory and general preparatory exercises of sportsmen (boxing, sporting hand-to-hand fight hopak, fencing. 42 sportsmen took part in researches. Statistical reliable intercommunications are set: a indexes of force of shots by hands with the indexes of rate of single movement; b indexes of force of shots by feet with indexes from maximal force of muscles (tractive forces; c indexes of speed of shots by hands (pricking with the indexes of distance of shove of balls by mass 300 gramme; d indexes of speed of movement a step in a battle bar with indexes: speeds of shots by hands (pricking; e indexes of frequency of shots of boxers and sportsmen hand-to-hand fight hopak with the indexes of frequency of movement (manoeuvring on feet. Facilities which it is expedient to apply in the training process of single combats on this stage of long-term preparation are certain.

  18. Single cell analysis facilitates staging of Blimp1-dependent primordial germ cells derived from mouse embryonic stem cells.

    Directory of Open Access Journals (Sweden)

    John J Vincent

    Full Text Available The cell intrinsic programming that regulates mammalian primordial germ cell (PGC development in the pre-gonadal stage is challenging to investigate. To overcome this we created a transgene-free method for generating PGCs in vitro (iPGCs from mouse embryonic stem cells (ESCs. Using labeling for SSEA1 and cKit, two cell surface molecules used previously to isolate presumptive iPGCs, we show that not all SSEA1+/cKit+ double positive cells exhibit a PGC identity. Instead, we determined that selecting for cKit(bright cells within the SSEA1+ fraction significantly enriches for the putative iPGC population. Single cell analysis comparing SSEA1+/cKit(bright iPGCs to ESCs and embryonic PGCs demonstrates that 97% of single iPGCs co-express PGC signature genes Blimp1, Stella, Dnd1, Prdm14 and Dazl at similar levels to e9.5-10.5 PGCs, whereas 90% of single mouse ESC do not co-express PGC signature genes. For the 10% of ESCs that co-express PGC signature genes, the levels are significantly lower than iPGCs. Microarray analysis shows that iPGCs are transcriptionally distinct from ESCs and repress gene ontology groups associated with mesoderm and heart development. At the level of chromatin, iPGCs contain 5-methyl cytosine bases in their DNA at imprinted and non-imprinted loci, and are enriched in histone H3 lysine 27 trimethylation, yet do not have detectable levels of Mvh protein, consistent with a Blimp1-positive pre-gonadal PGC identity. In order to determine whether iPGC formation is dependent upon Blimp1, we generated Blimp1 null ESCs and found that loss of Blimp1 significantly depletes SSEA1/cKit(bright iPGCs. Taken together, the generation of Blimp1-positive iPGCs from ESCs constitutes a robust model for examining cell-intrinsic regulation of PGCs during the Blimp1-positive stage of development.

  19. Single cell proteomics using frog (Xenopus laevis) blastomeres isolated from early stage embryos, which form a geometric progression in protein content

    OpenAIRE

    Sun, Liangliang; Dubiak, Kyle M.; Peuchen, Elizabeth H.; Zhang, Zhenbin; Zhu, Guijie; Huber, Paul W.; Dovichi, Norman J.

    2016-01-01

    Single cell analysis is required to understand cellular heterogeneity in biological systems. We propose that single cells (blastomeres) isolated from early stage invertebrate, amphibian, or fish embryos are ideal model systems for the development of technologies for single cell analysis. For these embryos, although cell cleavage is not exactly symmetric, the content per blastomere decreases roughly by half with each cell division, creating a geometric progression in cellular content. This pro...

  20. Decline of Cosmetic Outcomes Following Accelerated Partial Breast Irradiation Using Intensity Modulated Radiation Therapy: Results of a Single-Institution Prospective Clinical Trial

    International Nuclear Information System (INIS)

    Liss, Adam L.; Ben-David, Merav A.; Jagsi, Reshma; Hayman, James A.; Griffith, Kent A.; Moran, Jean M.; Marsh, Robin B.; Pierce, Lori J.

    2014-01-01

    Purpose: To report the final cosmetic results from a single-arm prospective clinical trial evaluating accelerated partial breast irradiation (APBI) using intensity modulated radiation therapy (IMRT) with active-breathing control (ABC). Methods and Materials: Women older than 40 with breast cancer stages 0-I who received breast-conserving surgery were enrolled in an institutional review board-approved prospective study evaluating APBI using IMRT administered with deep inspiration breath-hold. Patients received 38.5 Gy in 3.85-Gy fractions given twice daily over 5 consecutive days. The planning target volume was defined as the lumpectomy cavity with a 1.5-cm margin. Cosmesis was scored on a 4-category scale by the treating physician. Toxicity was scored according to National Cancer Institute Common Terminology Criteria for Adverse Events (CTCAE version 3.0). We report the cosmetic and toxicity results at a median follow-up of 5 years. Results: A total of 34 patients were enrolled. Two patients were excluded because of fair baseline cosmesis. The trial was terminated early because fair/poor cosmesis developed in 7 of 32 women at a median follow-up of 2.5 years. At a median follow-up of 5 years, further decline in the cosmetic outcome was observed in 5 women. Cosmesis at the time of last assessment was 43.3% excellent, 30% good, 20% fair, and 6.7% poor. Fibrosis according to CTCAE at last assessment was 3.3% grade 2 toxicity and 0% grade 3 toxicity. There was no correlation of CTCAE grade 2 or greater fibrosis with cosmesis. The 5-year rate of local control was 97% for all 34 patients initially enrolled. Conclusions: In this prospective trial with 5-year median follow-up, we observed an excellent rate of tumor control using IMRT-planned APBI. Cosmetic outcomes, however, continued to decline, with 26.7% of women having a fair to poor cosmetic result. These results underscore the need for continued cosmetic assessment for patients treated with APBI by technique

  1. Decline of Cosmetic Outcomes Following Accelerated Partial Breast Irradiation Using Intensity Modulated Radiation Therapy: Results of a Single-Institution Prospective Clinical Trial

    Energy Technology Data Exchange (ETDEWEB)

    Liss, Adam L. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Ben-David, Merav A. [Department of Radiation Oncology, The Sheba Medical Center, Ramat Gan (Israel); Jagsi, Reshma; Hayman, James A. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Griffith, Kent A. [Biostatistics Unit, University of Michigan, Ann Arbor, Michigan (United States); Moran, Jean M.; Marsh, Robin B. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Pierce, Lori J., E-mail: ljpierce@umich.edu [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States)

    2014-05-01

    Purpose: To report the final cosmetic results from a single-arm prospective clinical trial evaluating accelerated partial breast irradiation (APBI) using intensity modulated radiation therapy (IMRT) with active-breathing control (ABC). Methods and Materials: Women older than 40 with breast cancer stages 0-I who received breast-conserving surgery were enrolled in an institutional review board-approved prospective study evaluating APBI using IMRT administered with deep inspiration breath-hold. Patients received 38.5 Gy in 3.85-Gy fractions given twice daily over 5 consecutive days. The planning target volume was defined as the lumpectomy cavity with a 1.5-cm margin. Cosmesis was scored on a 4-category scale by the treating physician. Toxicity was scored according to National Cancer Institute Common Terminology Criteria for Adverse Events (CTCAE version 3.0). We report the cosmetic and toxicity results at a median follow-up of 5 years. Results: A total of 34 patients were enrolled. Two patients were excluded because of fair baseline cosmesis. The trial was terminated early because fair/poor cosmesis developed in 7 of 32 women at a median follow-up of 2.5 years. At a median follow-up of 5 years, further decline in the cosmetic outcome was observed in 5 women. Cosmesis at the time of last assessment was 43.3% excellent, 30% good, 20% fair, and 6.7% poor. Fibrosis according to CTCAE at last assessment was 3.3% grade 2 toxicity and 0% grade 3 toxicity. There was no correlation of CTCAE grade 2 or greater fibrosis with cosmesis. The 5-year rate of local control was 97% for all 34 patients initially enrolled. Conclusions: In this prospective trial with 5-year median follow-up, we observed an excellent rate of tumor control using IMRT-planned APBI. Cosmetic outcomes, however, continued to decline, with 26.7% of women having a fair to poor cosmetic result. These results underscore the need for continued cosmetic assessment for patients treated with APBI by technique.

  2. Accelerated Partial Breast Irradiation Is Safe and Effective Using Intensity-Modulated Radiation Therapy in Selected Early-Stage Breast Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lewin, Alan A., E-mail: alanl@baptisthealth.net [Department of Radiation Oncology, Baptist Hospital of Miami, Miami, FL (United States); Derhagopian, Robert [Department of Surgery, Baptist Hospital of Miami, Miami, FL (United States); Saigal, Kunal; Panoff, Joseph E. [Department of Radiation Oncology, University of Miami, Miami, FL (United States); Abitbol, Andre; Wieczorek, D. Jay; Mishra, Vivek [Department of Radiation Oncology, Baptist Hospital of Miami, Miami, FL (United States); Reis, Isildinha; Ferrell, Annapoorna [Division of Biostatistics, University of Miami, Miami, FL (United States); Moreno, Lourdes [Department of Radiation Oncology, Baptist Hospital of Miami, Miami, FL (United States); Takita, Cristiane [Department of Radiation Oncology, University of Miami, Miami, FL (United States)

    2012-04-01

    Purpose: To report the feasibility, toxicity, cosmesis, and efficacy of using intensity-modulated radiation therapy (IMRT) with respiratory gating to deliver accelerated partial breast irradiation (APBI) in selected Stage I/II breast cancer after breast-conserving surgery. Methods and Materials: Eligible patients with node-negative Stage I/II breast cancer were prospectively enrolled in an institutional review board approved protocol to receive APBI using IMRT after breast-conserving surgery. The target volume was treated at 3.8 Gy/fraction twice daily for 5 days, to a total dose of 38 Gy. Results: Thirty-six patients were enrolled for a median follow-up time of 44.8 months. The median tumor size was 0.98 cm (range, 0.08-3 cm). The median clinical target volume (CTV) treated was 71.4 cc (range, 19-231 cc), with the mean dose to the CTV being 38.96 Gy. Acute toxicities included Grade 1 erythema in 44% of patients and Grade 2 in 6%, Grade 1 hyperpigmentation in 31% of patients and Grade 2 in 3%, and Grade 1 breast/chest wall tenderness in 14% of patients. No Grade 3/4 acute toxicities were observed. Grade 1 and 2 late toxicities as edema, fibrosis, and residual hyperpigmentation occurred in 14% and 11% of patients, respectively; Grade 3 telangiectasis was observed in 3% of patients. The overall cosmetic outcome was considered 'excellent' or 'good' by 94% of patients and 97% when rated by the physician, respectively. The local control rate was 97%; 1 patient died of a non-cancer-related cause. Conclusions: APBI can be safely and effectively administered using IMRT. In retrospective analysis, IMRT enabled the achievement of normal tissue dose constraints as outlined by Radiation Therapy Oncology Group 04-13/NSABP B-13 while providing excellent conformality for the CTV. Local control and cosmesis have remained excellent at current follow-up, with acceptable rates of acute/late toxicities. Our data suggest that cosmesis is dependent on target volume

  3. Accelerated Partial Breast Irradiation Is Safe and Effective Using Intensity-Modulated Radiation Therapy in Selected Early-Stage Breast Cancer

    International Nuclear Information System (INIS)

    Lewin, Alan A.; Derhagopian, Robert; Saigal, Kunal; Panoff, Joseph E.; Abitbol, Andre; Wieczorek, D. Jay; Mishra, Vivek; Reis, Isildinha; Ferrell, Annapoorna; Moreno, Lourdes; Takita, Cristiane

    2012-01-01

    Purpose: To report the feasibility, toxicity, cosmesis, and efficacy of using intensity-modulated radiation therapy (IMRT) with respiratory gating to deliver accelerated partial breast irradiation (APBI) in selected Stage I/II breast cancer after breast-conserving surgery. Methods and Materials: Eligible patients with node-negative Stage I/II breast cancer were prospectively enrolled in an institutional review board approved protocol to receive APBI using IMRT after breast-conserving surgery. The target volume was treated at 3.8 Gy/fraction twice daily for 5 days, to a total dose of 38 Gy. Results: Thirty-six patients were enrolled for a median follow-up time of 44.8 months. The median tumor size was 0.98 cm (range, 0.08–3 cm). The median clinical target volume (CTV) treated was 71.4 cc (range, 19–231 cc), with the mean dose to the CTV being 38.96 Gy. Acute toxicities included Grade 1 erythema in 44% of patients and Grade 2 in 6%, Grade 1 hyperpigmentation in 31% of patients and Grade 2 in 3%, and Grade 1 breast/chest wall tenderness in 14% of patients. No Grade 3/4 acute toxicities were observed. Grade 1 and 2 late toxicities as edema, fibrosis, and residual hyperpigmentation occurred in 14% and 11% of patients, respectively; Grade 3 telangiectasis was observed in 3% of patients. The overall cosmetic outcome was considered “excellent” or “good” by 94% of patients and 97% when rated by the physician, respectively. The local control rate was 97%; 1 patient died of a non–cancer-related cause. Conclusions: APBI can be safely and effectively administered using IMRT. In retrospective analysis, IMRT enabled the achievement of normal tissue dose constraints as outlined by Radiation Therapy Oncology Group 04-13/NSABP B-13 while providing excellent conformality for the CTV. Local control and cosmesis have remained excellent at current follow-up, with acceptable rates of acute/late toxicities. Our data suggest that cosmesis is dependent on target volume size

  4. Characterization and single-stage denitrification anaerobic digestion of spent stream from the hydrolysis-fermentation-combustion process

    Science.gov (United States)

    Singh, Ramnik

    The demand for ethanol as an oxygenate and octane booster in automobile fuel is growing. A number of processes are being investigated for conversion of biomass to ethanol. The Hydrolysis-Fermentation-Combustion (HFC) process for fuel ethanol production developed at the University of California Forest Products Laboratory, Richmond, California is at the stage of technology transfer following over two decades of research and development. This study addresses the technology to be used in treatment of spent streams to be discharged from this process. The treatment design combines a single stage denitrification and anaerobic digestion (SSDAD) for the biological treatment of a representative stream from this process. A typical spent stream contained a wide range of soluble organic materials including: unfermented sugars, components of the feedstocks solubilized in the hydrolysis, acid degradation products of carbohydrates, cleavage products of lignin, water-soluble extractives and phenolics, terpenes and other unfermented organic material, and nitrate ion from the nitric acid used as a catalyst in the hydrolysis reaction. Three sets of experiments were conducted in laboratory scale anaerobic digesters. Commonly available anaerobic sludge from local sewage treatment plants was used as a starter seed and was successfully acclimated to the high nitrate substrate leading to enrichment of denitrifiers. Necessary nutrients and trace elements were identified and supplied to satisfy the obligatory requirements of different groups of bacterial groups present. A major finding was the unique role of ammonium hydroxide in controlling pH leading to steady-state operation of the digester. At steady state operation the reduction in COD was 65%, the nitrate reduction was 88% and the nitrite reduction was 100%. Nitrate was reduced to safe nitrogen gas without buildup of any intermediate products. Organic material was converted to useful methane gas and carbon dioxide. The SSDAD system was

  5. Single-particle dynamics in a nonlinear accelerator lattice: attaining a large tune spread with octupoles in IOTA

    Energy Technology Data Exchange (ETDEWEB)

    Antipov, S. A.; Nagaitsev, S.; Valishev, A.

    2017-04-01

    Fermilab is constructing the Integrable Optics Test Accelerator (IOTA) as the centerpiece of the Accelerator R&D Program towards high-intensity circular machines. One of the factors limiting the beam intensity in present circular accelerators is collective instabilities, which can be suppressed by a spread of betatron frequencies (tunes) through the Landau damping mechanism or by an external damper, if the instability is slow enough. The spread is usually created by octupole magnets, which introduce the tune dependence on the amplitude and, in some cases, by a chromatic spread (tune dependence on particle's momentum). The introduction of octupoles usually lead to a resonant behavior and a reduction of the dynamic aperture. One of the goals of the IOTA research program is to achieve a high betatron tune spread, while retaining a large dynamic aperture using conventional octupole magnets in a special but realistic accelerator configuration. In this report, we present results of computer simulations of an electron beam in the IOTA by particle tracking and the Frequency Map Analysis. The results show that the ring's octupole magnets can be configured to provide a betatron tune shift of 0.08 (for particles at large amplitudes) with the dynamical aperture of over 20 beam sigma for a 150-MeV electron beam. The influence of the synchrotron motion, lattice errors, and magnet imperfections is insignificant for the parameters and levels of tolerances set by the design of the ring. The described octupole insert could be beneficial for suppression of space-charge induced instabilities in high intensity machines.

  6. Prospective study of single-stage repair of contaminated hernias using a biologic porcine tissue matrix: the RICH Study.

    Science.gov (United States)

    Itani, Kamal M F; Rosen, Michael; Vargo, Daniel; Awad, Samir S; Denoto, George; Butler, Charles E

    2012-09-01

    In the presence of contamination, the repair of a ventral incisional hernia (VIH) is challenging. The presence of comorbidities poses an additional risk for postoperative wound events and hernia recurrence. To date, very few studies describe the outcomes of VIH repair in this high-risk population. A prospective, multicenter, single-arm, the Repair of Infected or Contaminated Hernias study was performed to study the clinical outcomes of open VIH repair of contaminated abdominal defects with a non-cross-linked, porcine, acellular dermal matrix, Strattice. Of 85 patients who consented to participate, 80 underwent open VIH repair with Strattice. Hernia defects were 'clean-contaminated' (n = 39), 'contaminated' (n = 39), or 'dirty' (n = 2), and the defects were classified as grade 3 (n = 60) or grade 4 (n = 20). The midline was restored, and primary closure was achieved in 64 patients; the defect was bridged in 16 patients. At 24 months, 53 patients (66%) experienced 95 wound events. There were 28 unique, infection-related events in 24 patients. Twenty-two patients experienced seromas, all but 5 of which were transient and required no intervention. No unanticipated adverse events occurred, and no tissue matrix required complete excision. There were 22 hernia (28%) recurrences by month 24. There was no correlation between infection-related events and hernia recurrence. The use of the intact, non-cross-linked, porcine, acellular dermal matrix, Strattice, in the repair of contaminated VIH in high-risk patients allowed for successful, single-stage reconstruction in >70% of patients followed for 24 months after repair. Published by Mosby, Inc.

  7. A Robust High-Performance GPS L1 Receiver with Single-stage Quadrature Redio-Frequency Circuit

    Science.gov (United States)

    Liu, Jianghua; Xu, Weilin; Wan, Qinq; Liu, Tianci

    2018-03-01

    A low power current reuse single-stage quadrature raido-frequency part (SQRF) is proposed for GPS L1 receiver in 180nm CMOS process. The proposed circuit consists of LNA, Mixer, QVCO, is called the QLMV cell. A two blocks stacked topology is adopted in this design. The parallel QVCO and mixer placed on the top forms the upper stacked block, and the LNA placed on the bottom forms the other stacked block. The two blocks share the current and achieve low power performance. To improve the stability, a float current source is proposed. The float current isolated the local oscillation signal and the input RF signal, which bring the whole circuit robust high-performance. The result shows conversion gain is 34 dB, noise figure is three dB, the phase noise is -110 dBc/Hz at 1MHz and IIP3 is -20 dBm. The proposed circuit dissipated 1.7mW with 1 V supply voltage.

  8. FunSAV: predicting the functional effect of single amino acid variants using a two-stage random forest model.

    Directory of Open Access Journals (Sweden)

    Mingjun Wang

    Full Text Available Single amino acid variants (SAVs are the most abundant form of known genetic variations associated with human disease. Successful prediction of the functional impact of SAVs from sequences can thus lead to an improved understanding of the underlying mechanisms of why a SAV may be associated with certain disease. In this work, we constructed a high-quality structural dataset that contained 679 high-quality protein structures with 2,048 SAVs by collecting the human genetic variant data from multiple resources and dividing them into two categories, i.e., disease-associated and neutral variants. We built a two-stage random forest (RF model, termed as FunSAV, to predict the functional effect of SAVs by combining sequence, structure and residue-contact network features with other additional features that were not explored in previous studies. Importantly, a two-step feature selection procedure was proposed to select the most important and informative features that contribute to the prediction of disease association of SAVs. In cross-validation experiments on the benchmark dataset, FunSAV achieved a good prediction performance with the area under the curve (AUC of 0.882, which is competitive with and in some cases better than other existing tools including SIFT, SNAP, Polyphen2, PANTHER, nsSNPAnalyzer and PhD-SNP. The sourcecodes of FunSAV and the datasets can be downloaded at http://sunflower.kuicr.kyoto-u.ac.jp/sjn/FunSAV.

  9. Heat transfer and oil flow studies on a single-stage-to-orbit control-configured winged entry vehicle

    Science.gov (United States)

    Helms, V. T., III; Bradley, P. F.

    1984-01-01

    Results are presented for oil flow and phase change paint heat transfer tests conducted on a 0.006 scale model of a proposed single stage to orbit control configured vehicle. The data were taken at angles of attack up to 40 deg at a free stream Mach number of 10 for Reynolds numbers based on model length of 0.5 x 10 to the 6th power, 1.0 x 10 to the 6th power and 2.0 x 10 to the 6th power. The magnitude and distribution of heating are characterized in terms of angle of attack and Reynolds number aided by an analysis of the flow data which are used to suggest the presence of various three dimensional flow structures that produce the observed heating patterns. Of particular interest are streak heating patterns that result in high localized heat transfer rates on the wing windward surface at low to moderate angles of attack. These streaks are caused by the bow-shock/wing-shock interaction and formation of the wing-shock. Embedded vorticity was found to be associated with these interactions.

  10. Phase 2 Study of Accelerated Hypofractionated Thoracic Radiation Therapy and Concurrent Chemotherapy in Patients With Limited-Stage Small-Cell Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Bing [Department of Radiation Oncology, Shanghai Cancer Center, Fudan University, Shanghai (China); Department of Radiation Oncology, Hangzhou Cancer Hospital, Hangzhou (China); Hong, Ling-Zhi [Department of Oncology, Nanjing First Hospital, Nanjing Medical University, Nanjing (China); Cai, Xu-Wei; Zhu, Zheng-Fei; Liu, Qi; Zhao, Kuai-Le; Fan, Min; Mao, Jing-Fang; Yang, Huan-Jun; Wu, Kai-Liang [Department of Radiation Oncology, Shanghai Cancer Center, Fudan University, Shanghai (China); Fu, Xiao-Long, E-mail: xlfu1964@hotmail.com [Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai (China)

    2015-03-01

    Purpose: To prospectively investigate the efficacy and toxicity of accelerated hypofractionated thoracic radiation therapy (HypoTRT) combined with concurrent chemotherapy in the treatment of limited-stage small-cell lung cancer (LS-SCLC), with the hypothesis that both high radiation dose and short radiation time are important in this setting. Methods and Materials: Patients with previously untreated LS-SCLC, Eastern Cooperative Oncology Group performance status of 0 to 2, and adequate organ function were eligible. HypoTRT of 55 Gy at 2.5 Gy per fraction over 30 days was given on the first day of the second or third cycle of chemotherapy. An etoposide/cisplatin regimen was given to 4 to 6 cycles. Patients who had a good response to initial treatment were offered prophylactic cranial irradiation. The primary endpoint was the 2-year progression-free survival rate. Results: Fifty-nine patients were enrolled from July 2007 through February 2012 (median age, 58 years; 86% male). The 2-year progression-free survival rate was 49.0% (95% confidence interval [CI] 35.3%-62.7%). Median survival time was 28.5 months (95% CI 9.0-48.0 months); the 2-year overall survival rate was 58.2% (95% CI 44.5%-71.9%). The 2-year local control rate was 76.4% (95% CI 63.7%-89.1%). The severe hematologic toxicities (grade 3 or 4) were leukopenia (32%), neutropenia (25%), and thrombocytopenia (15%). Acute esophagitis and pneumonitis of grade ≥3 occurred in 25% and 10% of the patients, respectively. Thirty-eight patients (64%) received prophylactic cranial irradiation. Conclusion: Our study showed that HypoTRT of 55 Gy at 2.5 Gy per fraction daily concurrently with etoposide/cisplatin chemotherapy has favorable survival and acceptable toxicity. This radiation schedule deserves further investigation in LS-SCLC.

  11. Effects of a saturated layer and recirculation on nitrogen treatment performances of a single stage Vertical Flow Constructed Wetland (VFCW).

    Science.gov (United States)

    Prigent, S; Paing, J; Andres, Y; Chazarenc, F

    2013-01-01

    Upgrades to enhance nitrogen removal were tested in a 2 year old pilot vertical flow constructed wetland in spring and summer periods. The effects of a saturated layer and of recirculation were tested in particular. Two pilots (L = 2 m, W = 1.25 m, H = 1.2 m), filled with expanded schist (Mayennite(®)), were designed with hydraulic saturated layers of 20 and 40 cm at the bottom. Each pilot was fed with raw domestic wastewater under field conditions according to a hydraulic load of 15-38 cm d(-1) (i.e. 158-401 g COD (chemical oxygen demand) m(-2) d(-1)) and to recirculation rates ranging from 0% up to 150%. The initial load during the first 2 years of operation resulted in an incomplete mineralized accumulated sludge leading to total suspended solids (TSS), COD and biochemical oxygen demand (BOD5) release. A 40 cm hydraulic saturated layer enabled an increase of 5-10% total nitrogen (TN) removal compared to a 20 cm saturated layer. Recirculation allowed the dilution of raw wastewater and enhanced nitrification in a single stage. A design of 1.8 m² pe(-1) (48 cm d(-1), 191 g COD m(-2) d(-1)) with a 40 cm saturated layer and 100% recirculation enabled the French standard D4 (35 mg TSS L(-1), 125 mg COD L(-1), 25 mg BOD5 L(-1)), nitrogen concentrations below 20 mg TKN (total Kjeldahl nitrogen) L(-1) and 50 mg TN L(-1), to be met.

  12. Influence of the effectiveness of raw materials on the reliability of thermoelectric cooling devices. Part I: single-stage TEDs

    Directory of Open Access Journals (Sweden)

    Zaikov V. P.

    2015-02-01

    Full Text Available Increase of the reliability of information systems depends on the reliability improvement of their component elements, including cooling devices, providing efficiency of thermally loaded components. Thermoelectric devices based on the Peltier effect have significant advantages compared with air and liquid systems for thermal modes of the radio-electronic equipment. This happens due to the absence of moving parts, which account for the failure rate. The article presents research results on how thermoelectric efficiency modules affect the failure rate and the probability of non-failure operation in the range of working temperature of thermoelectric coolers. The authors investigate a model of relative failure rate and the probability of failure-free operation single-stage thermoelectric devices depending on the main relevant parameters: the operating current flowing through the thermocouple and resistance, temperature changes, the magnitude of the heat load and the number of elements in the module. It is shown that the increase in the thermoelectric efficiency of the primary material for a variety of thermocouple temperature changes causes the following: maximum temperature difference increases by 18%; the number of elements in the module decreases; cooling coefficient increases; failure rate reduces and the probability of non-failure operation of thermoelectric cooling device increases. Material efficiency increase by 1% allows reducing failure rate by 2,6—4,3% in maximum refrigeration capacity mode and by 4,2—5,0% in minimal failure rate mode when temperature difference changes in the range of 40—60 K. Thus, the increase in the thermoelectric efficiency of initial materials of thermocouples can significantly reduce the failure rate and increase the probability of failure of thermoelectric coolers depending on the temperature difference and the current operating mode.

  13. A Three-Level Quasi-Two-Stage Single-Phase PFC Converter with Flexible Output Voltage and Improved Conversion Efficiency

    DEFF Research Database (Denmark)

    Tang, Yi; Zhu, Dexuan; Jin, Chi

    2015-01-01

    This paper presents a three-level quasi-two-stage single-phase power factor correction (PFC) converter that has flexible output voltage and improved conversion efficiency. The proposed PFC converter features sinusoidal input current, three-level output characteristic, and a wide range of output dc...

  14. An operational protocol for facilitating start-up of single-stage autotrophic nitrogen-removing reactors based on process stoichiometry

    DEFF Research Database (Denmark)

    Mutlu, Ayten Gizem; Vangsgaard, Anna Katrine; Sin, Gürkan

    2013-01-01

    Start-up and operation of single-stage nitritation–anammox sequencing batch reactors (SBRs) for completely autotrophic nitrogen removal can be challenging and far from trivial. In this study, a step-wise procedure is developed based on stoichiometric analysis of the process performance from...

  15. Enamel pits in hamster molars, formed by a single high fluoride dose, are associated with a perturbation of transitional stage ameloblasts

    NARCIS (Netherlands)

    Lyaruu, D.M.; Vermeulen, L.; Stienen, N.; Bervoets, T.J.M.; Denbesten, P.K.; Bronckers, A.L.J.J.

    2012-01-01

    Excessive intake of fluoride (F) by young children results in the formation of enamel subsurface porosities and pits, called enamel fluorosis. In this study, we used a single high dose of F administered to hamster pups to determine the stage of ameloblasts most affected by F and whether pit

  16. Temperature-phased anaerobic digestion of food waste: A comparison with single-stage digestions based on performance and energy balance.

    Science.gov (United States)

    Xiao, Benyi; Qin, Yu; Zhang, Wenzhe; Wu, Jing; Qiang, Hong; Liu, Junxin; Li, Yu-You

    2018-02-01

    The temperature-phased anaerobic digestion (TPAD) of food waste was studied for the purpose of comparing with single-stage mesophilic and thermophilic anaerobic digestion. The biogas and methane yields in the TPAD during the steady period were 0.759 ± 0.115 L/g added VS and 0.454 ± 0.201 L/g added VS, which were lower than those in the two single-stage anaerobic digestion. The improper sludge retention time may be the reason for the lower biogas and methane production in TPAD. The removal of volatile solids in the TPAD was 78.55 ± 4.59% and the lowest among the three anaerobic digestion processes. The reaction ratios of the four anaerobic digestion steps in the TPAD were all lower than those in the two single-stage anaerobic digestion. The energy conversion efficiency of the degraded substrate in the TPAD was similar with those in single-stage mesophilic and thermophilic anaerobic digestion systems. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Characteristics and Sampling Efficiencies of Two Impactor Bioaerosol Samplers: MAS-100(Registered) (Microbial Air Monitoring System) and Single-Stage Andersen Viable Microbial Samplers

    National Research Council Canada - National Science Library

    Hottell, K

    2004-01-01

    .... A petri dish with agar is used as the impaction surface for these samplers. The MAS-l00 is a single-stage impactor that aspirates air through a 400-hole perforated entry plate onto an agar plate at an airflow rate of 100 L/min...

  18. Linac project - actual stage

    International Nuclear Information System (INIS)

    Carlin Filho, N.

    1990-01-01

    The actual development stage of Pelletron accelerator to study heavy ion reactions, nuclear structures and applied nuclear physics is presented. The construction of acceleration systems able to provide beams of several mass and energies up to 20 MeV/A, is discussed, describing acceleration structures and implemented systems. (M.C.K.)

  19. Advances in single- and multi-stage Stirling-type pulse tube cryocoolers for space applications in NLIP/SITP/CAS

    Science.gov (United States)

    Dang, Haizheng; Tan, Jun; Zha, Rui; Li, Jiaqi; Zhang, Lei; Zhao, Yibo; Gao, Zhiqian; Bao, Dingli; Li, Ning; Zhang, Tao; Zhao, Yongjiang; Zhao, Bangjian

    2017-12-01

    This paper presents a review of recent advances in single- and multi-stage Stirling-type pulse tube cryocoolers (SPTCs) for space applications developed at the National Laboratory for Infrared Physics, Shanghai Institute of Technical Physics, Chinese Academy of Sciences (NLIP/SITP/CAS). A variety of single-stage SPTCs operating at 25-150 K have been developed, including several mid-sized ones operating at 80-110 K. Significant progress has been achieved in coolers operating at 30-40 K which use common stainless steel meshes as regenerator matrices. Another important advance is the micro SPTCs with an overall mass of 300-800 g operating at high frequencies varying from 100 Hz to 400 Hz. The main purpose of developing two-stage SPTCs is to simultaneously acquire cooling capacities at both stages, obviating the need for auxiliary precooling in various applications. The three-stage SPTCs are developed mainly for applications at around 10 K, which are also used for precooling the J-T coolers to achieve further lower temperatures. The four-stage SPTCs are developed to directly achieve the liquid helium temperature for cooling space low-Tc superconducting devices and for the deep space exploration as well. Several typical development programs are described and an overview of the cooler performances is presented.

  20. The new target chamber at LIPSION: The new translation stage and goniometer and the new irradiation platform for single cell experiments

    International Nuclear Information System (INIS)

    Nilsson, Charlotta; Petriconi, Silvio; Reinert, Tilo; Butz, Tilman

    2007-01-01

    A new target chamber as well as a new 7-axes translation stage with goniometer will shortly be implemented at the LIPSION nanoprobe in Leipzig. This new stage should enable linear motion as well as rotary motion with high precision, positioning accuracy and repeatability. These different features have been investigated online as well as offline, with encouraging results. Along with the new equipment, new software is also being developed, to provide stage control running over network. These software developments, including a graphical user interface, will also be described. As part of the new target chamber, a new external beam facility and irradiation platform for single ion experiments on single living cells is being assembled. A detailed description of the new cell irradiation platform, including beam extraction, new cell dishes, and cell recognition aspects will be given. It will be shown that the possibility of offline cell recognition, possibly using a differential interference contrast microscope, is an option

  1. Studying the effect of over-modulation on the output voltage of three-phase single-stage grid-connected boost inverter

    Directory of Open Access Journals (Sweden)

    A. Abbas Elserougi

    2013-09-01

    Full Text Available Voltage boosting is very essential issue in renewable-energy fed applications. The classical two-stage power conversion process is typically used to interface the renewable energy sources to the grid. For better efficiency, single-stage inverters are recommended. In this paper, the performance of single-stage three-phase grid-connected boost inverter is investigated when its gain is extended by employing over-modulation technique. Using of over-modulation is compared with the employment of third order harmonic injection. The latter method can increase the inverter gain by 15% without distorting the inverter output voltage. The performance of extended gain grid-connected boost inverter is also tested during normal operation as well as in the presence of grid side disturbances. Simulation and experimental results are satisfactory.

  2. Administration of toltrazuril during experimental coccidiosis in mule ducks: comparison of the efficacy of a single administration at two different endogenous stages.

    Science.gov (United States)

    Reynaud, M C; Chauve, C M; Gastellu, J; Gounel, J M

    1999-03-15

    An experimental Eimeria mulardi coccidiosis was reproduced in mule ducks. A single dose of toltrazuril (7 mg per kg) was administered at two different endogenous stages: Day 2 (first meronts) or Day 5 (last meronts and gamonts). The efficacy of the drug was assessed on four criteria (body weight, oocyst counts, macroscopic lesions, and presence of the meronts and gamonts). To have a curative effect, a single dose of toltrazuril should be administered early on. However, a single treatment on Day 5 had a prophylactic effect.

  3. Accelerating RF cavity of the Booster

    CERN Multimedia

    CERN PhotoLab

    1983-01-01

    Each of the 4 PS Booster rings has a single accelerating cavity.It consists of 2 quarter-wave ferrite-loaded resonators. 2 figure-of-eight loops tune the frequency throughout the accelerating cycle, from 3 to 8 MHz (from 50 MeV at injection to the original Booster energy of 800 MeV, 2 GeV today). The cavities have a flat design, to fit the ring-to-ring distance of 36 cm, and are forced-air cooled. The 2 round objects in the front-compartments are the final-stage power-tetrodes. See also 8111095.

  4. Is less also better? A single-institution experience on treatment of early stage Malignant Pleural Mesothelioma.

    Science.gov (United States)

    Bertoglio, P; Ambrogi, M C; Chella, A; Aprile, V; Dini, P; Korasidis, S; Fanucchi, O; Mussi, A

    2017-07-01

    No clear evidence of which surgical procedure should be performed for early stage mesothelioma is available to date. We analyzed our 10-year experience in the treatment of early stage mesothelioma with surgery and Hyperthermic IntraTHOracic Chemotherapy. We retrospectively analyzed all cases of histologically proven epithelioid or biphasic IMIG stage I and II mesothelioma that we operated between 2005 and 2014. We performed an open pleurectomy and partial decortication of any visible lesion on the visceral pleura in all cases and both diaphragm and pericardium were always spared; Hyperthermic IntraTHOracic Chemotherapy was ran using Cisplatin 80 mg/m 2 and Doxorubicin 25 mg/m 2 at a target temperature of 42.5 °C for 60 min. We operated on 26 patients (23 male and 3 female); epithelioid tumor was diagnosed in 23 cases. Twelve patients were in IMIG stage I and 14 in IMIG stage II; median overall survival for all patients, stage I and II were 35.6, 46 and 23 months respectively and disease free survival was 18, 18 and 16 months respectively. Our results for stage I were better than those reported in literature and were similar for stage II. We observe no 30- and 90- mortality and the rate of severe complication (all CTCAE stage 3) were 30%; the median postoperative stay was 7.5 days. Our lung sparing approach for the treatment of pleural mesothelioma in early stages allows promising long term outcomes with a complete sparing of pulmonary and diaphragmatic function. Larger studies are needed to confirm our good results. Copyright © 2017 Elsevier Ltd, BASO ~ The Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.

  5. First TRUE Stage - Transport of solutes in an interpreted single fracture. Proceedings from the 4th international seminar

    International Nuclear Information System (INIS)

    2001-08-01

    The First Stage of the Tracer Retention Understanding Experiments (TRUE-1) was initiated in 1994 and the experimental activities were officially concluded in December 1998 with the termination of the final test with radioactive sorbing tracers. The programme also included a laboratory programme focused on both generic (Aespoe HRL) and site-specific (Feature A) geological material. Modelling, both scopings, predictions and evaluation of the final tests with sorbing tracers has been performed parallel to the experimental work. The work and conclusions of the SKB TRUE project team have been published in a SKB technical report. The TRUE-1 experiments have also been subject to blind prediction and evaluation by an international group of modelling teams within the auspices of the Aespoe Task Force on Groundwater on Modelling of Groundwater Flow and Solute Transport. A list of relevant reports and publications related to the First TRUE Stage are presented in Appendix A. The present seminar provides a venue to present and discuss the results of the TRUE-1 experiments in terms of identified transport and retention processes and concepts/approaches used to model. However, given the fact that may international programs, including that of SKB, are either underway or preparing for site characterisation programs, the seminar provides a possibility to discuss research priorities and the specific data needs for development of a geological repository. In his opening address, the director of the Aespoe Hard Rock Laboratory emphasised the need to carefully integrate available experience from other research sites, e.g. Grimsel (Switzerland), Stripa (Sweden) and El Berrocal (Spain). The two important questions to be asked are; What do we know? What is the way forward? For the subsequent discussions four different discussion themes were identified; 1. Identification of transport processes. 2. Model concepts. 3. Site-specific data needs for a geological repository. 4. Research priorities

  6. Technology and staging effects on two-stage-to-orbit systems

    Science.gov (United States)

    Wilhite, Alan W.

    1991-01-01

    Horizontal takeoff and landing two-stage systems with an airbreathing first stage and rocket second stage are evaluated for staging Mach numbers that range from 5 to 14. All systems are evaluated with advanced technologies being developed in the NASP Program and sized to the same mission requirements. With these advanced technologies, the two-stage systems are heavier than the single stage. The weights of the two-stage systems are closely related to staging. Using a rocket on the first stage to accelerate from the turboramjet limit of Mach 6 to Mach 10 signiificantly decreases dry weight as compared to the Mach 6-staged system. The optimum dry weight staging Mach number for the scramjet two-stage system is Mach 12. At a 40 percent weight growth (current technology level), the scramjet two-stage systems are half the weight and less sensitive to weight changes than the single stage, but still require substantial technology development in the areas of inlets, nozzles, ramjet propulsion, active cooling, and high-temperature structures.

  7. Single-stage epidural catheter lavage with posterior spondylodesis in lumbar pyogenic spondylodiscitis with multilevel epidural abscess formation.

    Science.gov (United States)

    Tschoeke, Sven K; Kayser, Ralph; Gulow, Jens; Hoeh, Nicolas von der; Salis-Soglio, Georg von; Heyde, Christoph

    2014-11-01

    Despite significant advances in the conservative management of pyogenic spondylodiscitis, consecutive instability, deformity, and/or neurologic compromise demands a prompt surgical intervention. However, in rare cases involving additional multilevel epidural abscess formation, the appropriate surgical strategy remains controversial. In this retrospective cohort analyses, we evaluated the efficacy of a single-stage posterior approach with the addition of a one-time multilevel epidural lavage via the surgically exposed interlaminar fenestration of the infected segment. From January 2009 through December 2010, 73 patients presenting pyogenic spondylodiscitis with instability of the lumbar spine were admitted. In all cases, the surgical strategy included a radical resection of the affected intervertebral disc and stabilization by intervertebral fusion using a titanium cage with autologous bone grafting in a level-dependent posterior approach with additional pedicle screw-and-rod instrumentation. In cases where multilevel abscess formation was evident, the standard surgical procedure was complemented by drainage and irrigation of the abscess from posterior by carefully advancing a soft infant feeding tube via the surgically exposed epidural space under fluoroscopic guidance. All patients received complementary oral antibiotic therapy for 12 weeks and were followed-up for a minimum of 12 months postoperatively. Ten patients (three male and seven female patients; mean age: 64.9 ± 10.9 years) presented with an additional lumbar epidural abscess extending beyond three levels proximal or distal to the infected disc. In all 10 patients the laboratory-chemical inflammatory parameters (leukocyte count, C-reactive protein) remained within the physiologic range after completing antibiotic therapy throughout the 1-year follow-up period. The plain radiographs and magnetic resonance imaging demonstrated solid fusion and the complete remission of the initial abscess formation after

  8. Which Stage of ADPKD Is More Appropriate for Decortication? A Retrospective Study of 137 Patients from a Single Clinic.

    Directory of Open Access Journals (Sweden)

    Xiaoqiang Qian

    Full Text Available To study retrospectively the efficacy of decortication in patients with different stages of ADPKD and to determine which stage for decortication is more appropriate.We analyzed 137 patients with ADPKD from 2001 to 2010. All patients were divided into three stages. A total of 70 patients underwent decortication, and we studied intraoperative indicators and postoperative indicators at 1 and 3 years follow-up.In 70 patients who underwent decortication, significant differences were observed in operative duration and bleeding volume between patients with stage I and II ADPKD (P 0.05. The total complication occurrence rate was significantly different between them (P 0.05. Scr levels were significantly decreased in patients with stage II ADPKD in the 1st postoperative year (P 0.05. In the 1st postoperative year, VAS value, blood pressure and renal volume significantly differed (P 0.05.Decortication in patients with stage I ADPKD can alleviate back pain symptoms and decrease blood pressure within 1 year, but the long-term efficacy is not ideal. Scr levels can be maintained within normal limits, suggesting that decortication does not lead to deterioration of renal function. For patients with stage II ADPKD, decortication can significantly improve renal function over the short term. However, after 3 years, renal function returns to the preoperative level, and surgical difficulties and complications also increase.

  9. Single-stage endoscopic treatment for mild to moderate acute cholangitis associated with choledocholithiasis: a multicenter, non-randomized, open-label and exploratory clinical trial.

    Science.gov (United States)

    Eto, Kazunori; Kawakami, Hiroshi; Haba, Shin; Yamato, Hiroaki; Okuda, Toshinori; Yane, Kei; Hayashi, Tsuyoshi; Ehira, Nobuyuki; Onodera, Manabu; Matsumoto, Ryusuke; Matsubara, Yu; Takagi, Tomofumi; Sakamoto, Naoya

    2015-12-01

    Two-stage treatment involving stone removal after drainage is recommended for mild to moderate acute cholangitis associated with choledocholithiasis. However, single-stage treatment has some advantages. We aimed to assess the efficacy and safety of single-stage endoscopic treatment for mild to moderate acute cholangitis associated with choledocholithiasis. A multicenter, non-randomized, open-label, exploratory clinical trial was performed in 12 institutions. A total of 50 patients with a naïve papilla and a body temperature ≥37 °C who were diagnosed with mild to moderate cholangitis associated with choledocholithiasis were enrolled between August 2012 and February 2014. Of the 50 patients, 15 had mild cholangitis and 35 had moderate cholangitis. The median number of common bile duct stones was 2 (range, 1-8), and the median diameter of the common bile duct stones was 7.5 mm (range, 1-18). The cure rate of acute cholangitis within 4 days after single-stage treatment was 90% (45/50) based on a body temperature choledocholithiasis (clinical trial registration number: UMIN000008494). © 2015 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  10. Multi-stage versus single-stage inflation and deflation cycle for alternating low pressure air mattresses to prevent pressure ulcers in hospitalised patients: a randomised-controlled clinical trial.

    Science.gov (United States)

    Demarré, L; Beeckman, D; Vanderwee, K; Defloor, T; Grypdonck, M; Verhaeghe, S

    2012-04-01

    The duration and the amount of pressure and shear must be reduced in order to minimize the risk of pressure ulcer development. Alternating low pressure air mattresses with multi-stage inflation and deflation cycle of the air cells have been developed to relieve pressure by sequentially inflating and deflating the air cells. Evidence about the effectiveness of this type of mattress in clinical practice is lacking. This study aimed to compare the effectiveness of an alternating low pressure air mattress that has a standard single-stage inflation and deflation cycle of the air cells with an alternating low pressure air mattress with multi-stage inflation and deflation cycle of the air cells. A randomised controlled trial was performed in a convenience sample of 25 wards in five hospitals in Belgium. In total, 610 patients were included and randomly assigned to the experimental group (n=298) or the control group (n=312). In the experimental group, patients were allocated to an alternating low pressure air mattress with multi-stage inflation and deflation cycle of the air cells. In the control group, patients were allocated to an alternating low pressure air mattress with a standard single-stage inflation and deflation cycle of the air cells. The outcome was defined as cumulative pressure ulcer incidence (Grade II-IV). An intention-to-treat analysis was performed. There was no significant difference in cumulative pressure ulcer incidence (Grade II-IV) between both groups (Exp.=5.7%, Contr.=5.8%, p=0.97). When patients developed a pressure ulcer, the median time was 5.0 days in the experimental group (IQR=3.0-8.5) and 8.0 days in the control group (IQR=3.0-8.5) (Mann-Whitney U-test=113, p=0.182). The probability to remain pressure ulcer free during the observation period in this trial did not differ significantly between the experimental group and the control group (log-rank χ(2)=0.013, df=1, p=0.911). An alternating low pressure air mattress with multi-stage inflation

  11. Low Voltage Ride-Through Capability of a Single-Stage Single-Phase Photovoltaic System Connected to the Low-Voltage Grid

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede

    2013-01-01

    The progressively growing of single-phase photovoltaic (PV) systems makes the Distribution System Operators (DSO) to update or revise the existing grid codes in order to guarantee the availability, quality and reliability of the electrical system. It is expected that the future PV systems connected...... to the low-voltage grid will be more active with functionalities of low voltage ride-through (LVRT) and the grid support capability, which is not the case today. In this paper, the operation principle is demonstrated for a single-phase grid-connected PV system in low voltage ride through operation in order...... to map future challenges. The system is verified by simulations and experiments. Test results show that the proposed power control method is effective and the single-phase PV inverters connected to low-voltage networks are ready to provide grid support and ride-through voltage fault capability...

  12. Plasma wakefield acceleration experiments at FACET II

    Science.gov (United States)

    Joshi, C.; Adli, E.; An, W.; Clayton, C. E.; Corde, S.; Gessner, S.; Hogan, M. J.; Litos, M.; Lu, W.; Marsh, K. A.; Mori, W. B.; Vafaei-Najafabadi, N.; O'shea, B.; Xu, Xinlu; White, G.; Yakimenko, V.

    2018-03-01

    During the past two decades of research, the ultra-relativistic beam-driven plasma wakefield accelerator (PWFA) concept has achieved many significant milestones. These include the demonstration of ultra-high gradient acceleration of electrons over meter-scale plasma accelerator structures, efficient acceleration of a narrow energy spread electron bunch at high-gradients, positron acceleration using wakes in uniform plasmas and in hollow plasma channels, and demonstrating that highly nonlinear wakes in the ‘blow-out regime’ have the electric field structure necessary for preserving the emittance of the accelerating bunch. A new 10 GeV electron beam facility, Facilities for Accelerator Science and Experimental Test (FACET) II, is currently under construction at SLAC National Accelerator Laboratory for the next generation of PWFA research and development. The FACET II beams will enable the simultaneous demonstration of substantial energy gain of a small emittance electron bunch while demonstrating an efficient transfer of energy from the drive to the trailing bunch. In this paper we first describe the capabilities of the FACET II facility. We then describe a series of PWFA experiments supported by numerical and particle-in-cell simulations designed to demonstrate plasma wake generation where the drive beam is nearly depleted of its energy, high efficiency acceleration of the trailing bunch while doubling its energy and ultimately, quantifying the emittance growth in a single stage of a PWFA that has optimally designed matching sections. We then briefly discuss other FACET II plasma-based experiments including in situ positron generation and acceleration, and several schemes that are promising for generating sub-micron emittance bunches that will ultimately be needed for both an early application of a PWFA and for a plasma-based future linear collider.

  13. Effect of Die Head Temperature at Compounding Stage on the Degradation of Linear Low Density Polyethylene/Plastic Film Waste Blends after Accelerated Weathering

    OpenAIRE

    S. M. Al-Salem; N. M. Al-Dousari; G. Joseph Abraham; M. Aromin D’Souza; O. A. Al-Qabandi; W. Al-Zakri

    2016-01-01

    Accelerated weathering test was performed on blends of linear low density polyethylene (LLDPE) and plastic film waste constituting the following percentages of polyolefin polymers (wt.%): LLDPE (46%), low density polyethylene (LDPE, 51%), high density polyethylene (HDPE, 1%), and polypropylene (PP, 2%). Compounded blends were evaluated for their mechanical and physical (optical) properties. The impact of photodegradation on the formulated blends was studied, and loss of mechanical integrity w...

  14. Single-stage oxidative dehydrogenation of n-butaneand isopentane in adiabatic sectional reactors with supply of oxygene and water steam

    International Nuclear Information System (INIS)

    Azizov, A.G; Gadji-Kasumov, V.S

    2000-01-01

    Full text: The advanced technique of single-stage dehydrogenation of n-butane and iso-pentane in adiabatic sectional with separate supply of oxygen on every section is offered. The substance of the novel method consist in water metering for every section. Such technological technique considerably cut the specific energy expenses on high temperature water steam production, increase the yield and selectivity of main products formation at the expense of more complete partial oxidation of the correspondend olefins.

  15. Can Accelerators Accelerate Learning?

    International Nuclear Information System (INIS)

    Santos, A. C. F.; Fonseca, P.; Coelho, L. F. S.

    2009-01-01

    The 'Young Talented' education program developed by the Brazilian State Funding Agency (FAPERJ)[1] makes it possible for high-schools students from public high schools to perform activities in scientific laboratories. In the Atomic and Molecular Physics Laboratory at Federal University of Rio de Janeiro (UFRJ), the students are confronted with modern research tools like the 1.7 MV ion accelerator. Being a user-friendly machine, the accelerator is easily manageable by the students, who can perform simple hands-on activities, stimulating interest in physics, and getting the students close to modern laboratory techniques.

  16. Induction accelerators and free-electron lasers at LLNL

    International Nuclear Information System (INIS)

    Briggs, R.J.

    1989-01-01

    Linear induction accelerators have been developed to produce pulses of charged particles at voltages exceeding the capabilities of single-stage, diode-type accelerators and at currents too high for rf accelerators. In principle, one can accelerate charged particles to arbitrarily high voltages using a multi-stage induction machine. The advent of magnetic pulse power systems makes sustained operation at high repetition rates practical, and high-average-power capability is very likely to open up many new applications of induction machines. In part A of this paper, the US induction linac technology is surveyed emphasizing electron machines. A simplified description is given of how induction machines couple energy to the electron beam to illustrate many general issues that designers of high-brightness and high-average-power induction linacs must consider. An example is given of the application of induction accelerator technology to the relativistic klystron, a power source for high-gradient accelerators. In part B the application of LIAs to free-electron lasers is addressed. The multikiloampere peak currents available from linear induction accelerators make high-gain, free-electron laser amplifier configurations feasible. High extraction efficiencies in a single pass of the electron beam are possible if the wiggler parameters are appropriately tapered, as recently demonstrated at millimeter wavelengths on the 4-MeV ELF facility. Key issues involved in extending the technology to shorter wavelengths and higher average powers are described. Current FEL experiments at LLNL are discussed. 5 references, 16 figures, 1 table

  17. Optimizing and accelerating the assignation of lineages in Mycobacterium tuberculosis using novel alternative single-tube assays.

    Directory of Open Access Journals (Sweden)

    María Carcelén

    Full Text Available The assignation of lineages in Mycobacterium tuberculosis (MTB provides valuable information for evolutionary and phylogeographic studies and makes for more accurate knowledge of the distribution of this pathogen worldwide. Differences in virulence have also been found for certain lineages. MTB isolates were initially assigned to lineages based on data obtained from genotyping techniques, such as spoligotyping or MIRU-VNTR analysis, some of which are more suitable for molecular epidemiology studies. However, since these methods are subject to a certain degree of homoplasy, other criteria have been chosen to assign lineages. These are based on targeting robust and specific SNPs for each lineage. Here, we propose two newly designed multiplex targeting methods-both of which are single-tube tests-to optimize the assignation of the six main lineages in MTB. The first method is based on ASO-PCR and offers an inexpensive and easy-to-implement assay for laboratories with limited resources. The other, which is based on SNaPshot, enables more refined standardized assignation of lineages for laboratories with better resources. Both methods performed well when assigning lineages from cultured isolates from a control panel, a test panel, and a problem panel from an unrelated population, Mexico, which included isolates in which standard genotyping was not able to classify lineages. Both tests were also able to assign lineages from stored isolates, without the need for subculture or purification of DNA, and even directly from clinical specimens with a medium-high bacilli burden. Our assays could broaden the contexts where information on lineages can be acquired, thus enabling us to quickly update data from retrospective collections and to merge data with those obtained at the time of diagnosis of a new TB case.

  18. Performance and genome-centric metagenomics of thermophilic single and two-stage anaerobic digesters treating cheese wastes

    DEFF Research Database (Denmark)

    Fontana, Alessandra; Campanaro, Stefano; Treu, Laura

    2018-01-01

    configurations were remarkably different, demonstrating a higher methanogenic biodiversity in the two-stage configuration. In fact, the acidogenic reactor of the serial configuration was almost solely composed by the lactose degrader Bifidobacterium crudilactis UC0001. The predictive functional analyses...... Tepidanaerobacter acetatoxydans UC0018 and to the absence of aceticlastic methanogens....

  19. Development and testing of a three-stage double tandem accelerator-decelerator system for low energy, highly stripped ions. Progress report, March 1, 1978--February 28, 1979

    International Nuclear Information System (INIS)

    Bayfield, J.E.

    1978-11-01

    Three-stage operation of the University of Pittsburgh accel-decel double tandem source of highly stripped ion beams is described. The system has produced O 5+ , O 6+ , O 7+ , and O 8+ ions at specific energies as low as 15 keV per AMU. The design of the new decelerator tubes is discussed. The present performance and limitations of the overall system are outlined. Some new charge exchange cross sections have been measured, for combined higher ion charge states and lower ion energies than heretofore was possible. Future four-stage operation with very heavy ions is considered

  20. Development and testing of a three-stage double tandem accelerator-decelerator system for low energy, highly stripped ions. Progress report, March 1, 1978--February 28, 1979

    International Nuclear Information System (INIS)

    Bayfield, J.E.

    1978-11-01

    Three-stage operation of the University of Pittsburgh accel-decel double tandem source of highly stripped ion beams is described. The system has produced 0 5+ , 0 6+ , 0 7+ , and 0 8+ ions at specific energies as low as 15 keV per AMU. The design of the new decelerator tubes is discussed. The present performance and limitations of the overall system are outlined. Some new charge exchange cross sections have been measured, for combined higher ion charge states and lower ion energies than heretofore was possible. Future four-stage operation with very heavy ions is considered

  1. Accelerating patient access to novel biologics using stable pool-derived product for non-clinical studies and single clone-derived product for clinical studies.

    Science.gov (United States)

    Munro, Trent P; Le, Kim; Le, Huong; Zhang, Li; Stevens, Jennitte; Soice, Neil; Benchaar, Sabrina A; Hong, Robert W; Goudar, Chetan T

    2017-11-01

    Cell cloning and subsequent process development activities are on the critical path directly impacting the timeline for advancement of next generation therapies to patients with unmet medical needs. The use of stable cell pools for early stage material generation and process development activities is an enabling technology to reduce timelines. To successfully use stable pools during development, it is important that bioprocess performance and requisite product quality attributes be comparable to those observed from clonally derived cell lines. To better understand the relationship between pool and clone derived cell lines, we compared data across recent first in human (FIH) programs at Amgen including both mAb and Fc-fusion modalities. We compared expression and phenotypic stability, bioprocess performance, and product quality attributes between material derived from stable pools and clonally derived cells. Overall, our results indicated the feasibility of matching bioprocess performance and product quality attributes between stable pools and subsequently derived clones. These findings support the use of stable pools to accelerate the advancement of novel biologics to the clinic. © 2017 The Authors Biotechnology Progress published by Wiley Periodicals, Inc. on behalf of American Institute of Chemical Engineers Biotechnol. Prog., 33:1476-1482, 2017. © 2017 The Authors Biotechnology Progress published by Wiley Periodicals, Inc. on behalf of American Institute of Chemical Engineers.

  2. Clinical results of stereotactic body radiotherapy for Stage I small-cell lung cancer. A single institutional experience

    International Nuclear Information System (INIS)

    Shioyama, Yoshiyuki; Nakamura, Katsumasa; Sasaki, Tomonari; Ohga, Saiji; Yoshitake, Tadamasa; Nonoshita, Takeshi; Asai, Kaori; Terashima, Koutarou; Matsumoto, Keiji; Hirata, Hideki; Honda, Hiroshi

    2013-01-01

    The purpose of this study was to evaluate the treatment outcomes of stereotactic body radiotherapy (SBRT) for Stage I small-cell lung cancer (SCLC). From April 2003 to September 2009, a total of eight patients with Stage I SCLC were treated with SBRT in our institution. In all patients, the lung tumors were proven as SCLC pathologically. The patients' ages were 58-84 years (median: 74). The T-stage of the primary tumor was T1a in two, T1b in two and T2a in four patients. Six of the patients were inoperable because of poor cardiac and/or pulmonary function, and two patients refused surgery. SBRT was given using 7-8 non-coplanar beams with 48 Gy in four fractions. Six of the eight patients received 3-4 cycles of chemotherapy using carboplatin (CBDCA) + etoposide (VP-16) or cisplatin (CDDP) + irinotecan (CPT-11). The follow-up period for all patients was 6-60 months (median: 32). Six patients were still alive without any recurrence. One patient died from this disease and one died from another disease. The overall and disease-specific survival rate at three years was 72% and 86%, respectively. There were no patients with local progression of the lesion targeted by SBRT. Only one patient had nodal recurrence in the mediastinum at 12 months after treatment. The progression-free survival rate was 71%. No Grade 2 or higher SBRT-related toxicities were observed. SBRT plus chemotherapy could be an alternative to surgery with chemotherapy for inoperable patients with Stage I small-cell lung cancer. However, further investigation is needed using a large series of patients. (author)

  3. Posterior or Single-stage Combined Anterior and Posterior Approach Decompression for Treating Complex Cervical Spondylotic Myelopathy Coincident Multilevel Anterior and Posterior Compression.

    Science.gov (United States)

    Zhou, Xiaoxiao; Cai, Pan; Li, Yuwei; Wang, Haijiao; Xia, Shengli; Wang, Xiuhui

    2017-12-01

    A single-center, retrospective, longitudinal matched cohort clinical study of prospectively collected outcomes. To compare retrospectively the clinical outcomes and complications of the posterior approach laminoplasty and single-stage anterior approach laminoplasty combined with anterior cervical corpectomy and fusion and anterior cervical discectomy and fusion for treating patients with cervical spondylotic myelopathy coincident multilevel anterior and posterior compression, known as complex cervical spondylotic myelopathy (cCSM) here. The optimal surgical management of this type of cCSM remains controversial. Sixty-seven patients with multilevel cCSM underwent decompression surgery from 1996 to 2007. Among these patients, 31 underwent a single-stage combined approach with decompression (combined approach group) and 36 underwent laminoplasty for posterior approach (posterior approach group). Average operative duration, operative estimated blood loss, surgical costs, and cervical alignment were measured. Average operative duration, operative estimated blood loss, and surgical costs were significantly lower in the posterior approach group than those in the combined approach group (P0.05). No statistical difference was observed in the preoperative Cobb angle (P>0.05), whereas a significant statistical difference was observed for the postoperative Cobb angle (Pgroups. The surgical incidences of complications were 22.2% and 48.4% in the posterior and combined approach groups (Papproach laminoplasty and single-stage combined approach led to significant neurological improvement and pain reduction in the majority of patients. Both approaches showed similar results in terms of decompression and neurological improvement. The posterior approach was superior to the combined approach in terms of surgical costs, surgical time, blood loss, and complication rate.

  4. Laser-driven accelerators

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    Several devices for using laser fields have been proposed and they can be classified in three broad categories - 'far-field' accelerators (such as the principle of inverse free electron lasers), 'media' accelerators (which, for example, use the inverse Cherenkov effect or laser-controlled plasma waves), and 'near-field' accelerators (using a loaded guiding structure such as cavities or gratings). These different approaches come from the fact that a particle cannot be accelerated by the absorption of single photons (because of momentum conservation) and thus some other element has to intervene. (orig./HSI).

  5. Research on High Efficient Single-Phase Multi-Stage Interleaved Bridgeless PFC Frontend for Class-D Amplifiers

    DEFF Research Database (Denmark)

    Li, Qingnan; Thomsen, Ole Cornelius; Andersen, Michael A. E.

    2012-01-01

    In this paper, a 3.5kW single-phase high efficient interleaved Bridgeless PFC (IBPFC) is proposed for class-D amplifiers. This topology achieves a relatively higher efficiency in a wide output power range, which helps to reduce the energy consuming of the whole system. In addition, a detailed...

  6. Clinical utility of simultaneous whole-body 18F-FDG PET/MRI as a single-step imaging modality in the staging of primary nasopharyngeal carcinoma.

    Science.gov (United States)

    Chan, Sheng-Chieh; Yeh, Chih-Hua; Yen, Tzu-Chen; Ng, Shu-Hang; Chang, Joseph Tung-Chieh; Lin, Chien-Yu; Yen-Ming, Tsang; Fan, Kang-Hsing; Huang, Bing-Shen; Hsu, Cheng-Lung; Chang, Kai-Ping; Wang, Hung-Ming; Liao, Chun-Ta

    2018-03-03

    Both head and neck magnetic resonance imaging (MRI) and 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/computed tomography (CT) play a crucial role in the staging of primary nasopharyngeal carcinoma (NPC). In this study, we sought to prospectively investigate the clinical utility of simultaneous whole-body 18F-FDG PET/MRI for primary staging of NPC patients. We examined 113 patients with histologically confirmed NPC who underwent pretreatment, simultaneous whole-body PET/MRI and PET/CT for primary tumor staging. The images obtained with the different imaging modalities were interpreted independently and compared with each other. PET/MRI increased the accuracy of head and neck MRI for assessment of primary tumor extent in four patients via addition of FDG uptake information to increase the conspicuity of morphologically subtle lesions. PET/MR images were more discernible than PET/CT images for mapping tumor extension, especially intracranial invasion. Regarding the N staging assessment, the sensitivity of PET/MRI (99.5%) was higher than that of head and neck MRI (94.2%) and PET/CT (90.9%). PET/MRI was particularly useful for distinguishing retropharyngeal nodal metastasis from adjacent nasopharyngeal tumors. For distant metastasis evaluation, PET/MRI exhibited a similar sensitivity (90% vs. 86.7% vs. 83.3%), but higher positive predictive value (93.1% vs. 78.8% vs. 83.3%) than whole-body MRI and PET/CT, respectively. For tumor staging of NPC, simultaneous whole-body PET/MRI was more accurate than head and neck MRI and PET/CT, and may serve as a single-step staging modality.

  7. Postoperative radiotherapy for completely resected Masaoka stage III thymoma: a retrospective study of 65 cases from a single institution

    International Nuclear Information System (INIS)

    Fan, Chengcheng; Hui, Zhouguang; Liang, Jun; Lv, Jima; Mao, Yousheng; Wang, Luhua; He, Jie; Feng, Qinfu; Chen, Yidong; Zhai, Yirui; Zhou, Zongmei; Chen, Dongfu; Xiao, Zefen; Zhang, Hongxing; Li, Jian

    2013-01-01

    The role of adjuvant radiotherapy (RT) for patients with stage III thymoma after complete resection is not definite. Some authors have advocated postoperative RT after complete tumor resection, but some others suggested observation. In this study, we retrospectively evaluated the effect of postoperative RT on survival as well as tumor control in patients with Masaoka stage III thymoma. Between June 1982 and December 2010, 65 patients who underwent complete resection of stage III thymoma entered the study. Fifty-three patients had adjuvant RT after surgery (S + R) and 12 had surgery only (S alone). Of patients who had adjuvant RT, 28 had three-dimensional conformal RT (3D-CRT)/intensity modulated RT (IMRT) and 25 had conventional RT. A median prescribed dose of 56 Gy (range, 28–60 Gy) was given. The median follow-up time was 50 months (range, 5–360 months). Five- and 10-year overall survival (OS) rates were 91.7% and 71.6%, respectively, for S + R and 81.5% and 65.2% for S alone (P = 0.5), respectively. In the subgroup analysis, patients with 3D-CRT/IMRT showed a trend of improved 5-year OS rate compared with conventional RT (100% vs. 86.9%, P =0.12). Compared with S alone, the 5-year OS rate was significantly improved (100% vs. 81.5%, P = 0.049). Relapses occurred in 15 patients (23.1%). There was a trend of lower crude local recurrence rates for S + R (3.8%) compared with S alone (16.7%) (P = 0.09), whereas the crude regional recurrence rates were similar (P = 0.9). No clear dose–response relationship was found according to prescribed doses. Adjuvant 3D-CRT/IMRT showed potential advantages in improving survival and reducing relapse in patients with stage III thymoma after complete resection, whereas adjuvant RT did not significantly improve survival or reduce recurrence for the cohort as a whole. Doses of ≤ 50 Gy may be effective and could be prescribed for adjuvant RT. To confirm the role of adjuvant 3D-CRT/IMRT in patients who undergo a complete

  8. MRI-guided single fraction ablative radiotherapy for early-stage breast cancer: a brachytherapy versus volumetric modulated arc therapy dosimetry study.

    Science.gov (United States)

    Charaghvandi, Ramona K; den Hartogh, Mariska D; van Ommen, Anne-Mar L N; de Vries, Wilfred J H; Scholten, Vincent; Moerland, Marinus A; Philippens, Mariëlle E P; Schokker, Rogier I; van Vulpen, Marco; van Asselen, Bram; van den Bongard, Desirée H J G

    2015-12-01

    A radiosurgical treatment approach for early-stage breast cancer has the potential to minimize the patient's treatment burden. The dosimetric feasibility for single fraction ablative radiotherapy was evaluated by comparing volumetric modulated arc therapy (VMAT) with an interstitial multicatheter brachytherapy (IMB) approach. The tumors of 20 patients with early-stage breast cancer were delineated on a preoperative contrast-enhanced planning CT-scan, co-registered with a contrast-enhanced magnetic resonance imaging (MRI), both in radiotherapy supine position. A dose of 15 Gy was prescribed to the planned target volume of the clinical target volume (PTVCTV), and 20 Gy integrated boost to the PTV of the gross tumor volume (PTVGTV). Treatment plans for IMB and VMAT were optimized for adequate target volume coverage and minimal organs at risk (OAR) dose. The median PTVGTV/CTV receiving at least 95% of the prescribed dose was ⩾99% with both techniques. The median PTVCTV unintentionally receiving 95% of the prescribed PTVGTV dose was 65.4% and 4.3% with IMB and VMAT, respectively. OAR doses were comparable with both techniques. MRI-guided single fraction radiotherapy with an integrated ablative boost to the GTV is dosimetrically feasible with both techniques. We perceive IMB less suitable for clinical implementation due to PTVCTV overdosage. Future studies have to confirm the clinical feasibility of the single fraction ablative approach. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  9. Analysis of honeybush tea (Cyclopia spp.) volatiles by comprehensive two-dimensional gas chromatography using a single-stage thermal modulator.

    Science.gov (United States)

    Ntlhokwe, Gaalebalwe; Tredoux, Andreas G J; Górecki, Tadeusz; Edwards, Matthew; Vestner, Jochen; Muller, Magdalena; Erasmus, Lené; Joubert, Elizabeth; Christel Cronje, J; de Villiers, André

    2017-07-01

    The applicability of comprehensive two-dimensional gas chromatography (GC×GC) using a single-stage thermal modulator was explored for the analysis of honeybush tea (Cyclopia spp.) volatile compounds. Headspace solid phase micro-extraction (HS-SPME) was used in combination with GC×GC separation on a non-polar × polar column set with flame ionisation (FID) detection for the analysis of fermented Cyclopia maculata, Cyclopia subternata and Cyclopia genistoides tea infusions of a single harvest season. Method optimisation entailed evaluation of the effects of several experimental parameters on the performance of the modulator, the choice of columns in both dimensions, as well as the HS-SPME extraction fibre. Eighty-four volatile compounds were identified by co-injection of reference standards. Principal component analysis (PCA) showed clear differentiation between the species based on their volatile profiles. Due to the highly reproducible separations obtained using the single-stage thermal modulator, multivariate data analysis was simplified. The results demonstrate both the complexity of honeybush volatile profiles and the potential of GC×GC separation in combination with suitable data analysis techniques for the investigation of the relationship between sensory properties and volatile composition of these products. The developed method therefore offers a fast and inexpensive methodology for the profiling of honeybush tea volatiles. Graphical abstract Surface plot obtained for the GC×GC-FID analysis of honeybush tea volatiles.

  10. Acceleration Mechanisms

    OpenAIRE

    Melrose, D. B.

    2009-01-01

    Glossary I. Background and context of the subject II. Stochastic acceleration III. Resonant scattering IV. Diffusive shock acceleration V. DSA at multiple shocks VI. Applications of DSA VII. Acceleration by parallel electric fields VIII. Other acceleration mechanisms IX. Future directions X. Appendix: Quasilinear equations XI. Bibliography

  11. DART-bid: dose-differentiated accelerated radiation therapy, 1.8 Gy twice daily. High local control in early stage (I/II) non-small-cell lung cancer

    International Nuclear Information System (INIS)

    Zehentmayr, Franz; Wurstbauer, Karl; Deutschmann, Heinz; Sedlmayer, Felix; Fussl, Christoph; Kopp, Peter; Dagn, Karin; Fastner, Gerd; Porsch, Peter; Studnicka, Michael

    2015-01-01

    While surgery is considered standard of care for early stage (I/II), non-small-cell lung cancer (NSCLC), radiotherapy is a widely accepted alternative for medically unfit patients or those who refuse surgery. International guidelines recommend several treatment options, comprising stereotactic body radiation therapy (SBRT) for small tumors, conventional radiotherapy ≥ 60 Gy for larger sized especially centrally located lesions or continuous hyperfractionated accelerated RT (CHART). This study presents clinical outcome and toxicity for patients treated with a dose-differentiated accelerated schedule using 1.8 Gy bid (DART-bid). Between April 2002 and December 2010, 54 patients (median age 71 years, median Karnofsky performance score 70 %) were treated for early stage NSCLC. Total doses were applied according to tumor diameter: 73.8 Gy for 6 cm. The median follow-up was 28.5 months (range 2-108 months); actuarial local control (LC) at 2 and 3 years was 88 %, while regional control was 100 %. There were 10 patients (19 %) who died of the tumor, and 18 patients (33 %) died due to cardiovascular or pulmonary causes. A total of 11 patients (20 %) died intercurrently without evidence of progression or treatment-related toxicity at the last follow-up, while 15 patients (28 %) are alive. Acute esophagitis ≤ grade 2 occurred in 7 cases, 2 patients developed grade 2 chronic pulmonary fibrosis. DART-bid yields high LC without significant toxicity. For centrally located and/or large (> 5 cm) early stage tumors, where SBRT is not feasible, this method might serve as radiotherapeutic alternative to present treatment recommendations, with the need of confirmation in larger cohorts. (orig.) [de

  12. DART-bid: dose-differentiated accelerated radiation therapy, 1.8 Gy twice daily: high local control in early stage (I/II) non-small-cell lung cancer.

    Science.gov (United States)

    Zehentmayr, Franz; Wurstbauer, Karl; Deutschmann, Heinz; Fussl, Christoph; Kopp, Peter; Dagn, Karin; Fastner, Gerd; Porsch, Peter; Studnicka, Michael; Sedlmayer, Felix

    2015-03-01

    While surgery is considered standard of care for early stage (I/II), non-small-cell lung cancer (NSCLC), radiotherapy is a widely accepted alternative for medically unfit patients or those who refuse surgery. International guidelines recommend several treatment options, comprising stereotactic body radiation therapy (SBRT) for small tumors, conventional radiotherapy ≥ 60 Gy for larger sized especially centrally located lesions or continuous hyperfractionated accelerated RT (CHART). This study presents clinical outcome and toxicity for patients treated with a dose-differentiated accelerated schedule using 1.8 Gy bid (DART-bid). Between April 2002 and December 2010, 54 patients (median age 71 years, median Karnofsky performance score 70%) were treated for early stage NSCLC. Total doses were applied according to tumor diameter: 73.8 Gy for 6 cm. The median follow-up was 28.5 months (range 2-108 months); actuarial local control (LC) at 2 and 3 years was 88%, while regional control was 100%. There were 10 patients (19%) who died of the tumor, and 18 patients (33%) died due to cardiovascular or pulmonary causes. A total of 11 patients (20%) died intercurrently without evidence of progression or treatment-related toxicity at the last follow-up, while 15 patients (28%) are alive. Acute esophagitis ≤ grade 2 occurred in 7 cases, 2 patients developed grade 2 chronic pulmonary fibrosis. DART-bid yields high LC without significant toxicity. For centrally located and/or large (> 5 cm) early stage tumors, where SBRT is not feasible, this method might serve as radiotherapeutic alternative to present treatment recommendations, with the need of confirmation in larger cohorts.

  13. Single-stage gain-clamped L-band EDFA with C-band ASE self-oscillation in ring cavity

    International Nuclear Information System (INIS)

    Mahdi, M A; Al-Mansoori, M H; Bakar, A A A; Shaari, S; Zamzuri, A K

    2008-01-01

    We demonstrate single-stage gain-clamped L-band Er 3+ -doped fiber amplifier (EDFA) utilizing self-oscillation modes as the control light. The amplifier structure exploits the characteristics of C/L-band coupler to isolate between lasing modes and L-band signal. The self-lasing cavity modes are obtained without any tunable bandpass filter in the loop and generated from the amplified spontaneous emission in the C-band region. The amplifier configuration has lower noise figures as opposed to a dual-stage partially gain-clamped amplifier. The gain and noise figure fluctuations are less than ± 0.4 dB in the gain-clamping region. The transient analysis confirms that the maximum power excursion is less than 0.3 dB for 10-dB add/drop

  14. Performance analysis of the single-stage absorption heat transformer using a new working pair composed of ionic liquid and water

    International Nuclear Information System (INIS)

    Zhang Xiaodong; Hu Dapeng

    2012-01-01

    The performance simulation of a single-stage absorption heat transformer using a new working pair composed of ionic liquids, 1-ethyl-3-methylimidazolium dimethylphosphate, and water (H 2 O + [EMIM][DMP]), was performed based on the thermodynamic properties of the new working pair and on the mass and energy balance for each component of the system. In order to evaluate the new working pair, the simulation results were compared with those of aqueous solution of lithium bromide (H 2 O + LiBr), Trifluoroethanol (TFE) + tetraethylenglycol dimethylether (E181). The results indicate that when generation, evaporation, condensing and absorption temperatures are 90 °C, 90 °C, 35 °C and 130 °C, the coefficients of performance of the single-stage absorption heat transformer using H 2 O + LiBr, H 2 O + [EMIM][DMP] and TFE + E181 as working pairs will reach 0.494, 0.481 and 0.458 respectively. And the corresponding exergy efficiency will reach 0.64, 0.62 and 0.59, respectively. Meanwhile the available heat outputs for per unit mass of refrigerant are 2466 kJ/kg, 2344 kJ/kg and 311 kJ/kg, respectively. The above excellent cycle performance together with the advantages of negligible vapor pressure, no crystallization and more weak corrosion tendency to iron-steel materials may make the new working pair better suited for the industrial absorption heat transformer. - Highlights: ► The cycle performance of the single-stage absorption heat transformer was simulated. ► Water and 1-ethyl-3-methylimidazolium dimethylphosphate was used as new working pair. ► Water and 1-ethyl-3-methylimidazolium dimethylphosphate are entirely miscible. ► The COP and exergy efficiency for this new working pairs were 0.481 and 0.62. ► The new working pairs has potential application to absorption heat transformer.

  15. Retrospective analysis of 56 edentulous dental arches restored with 344 single-stage implants using an immediate loading fixed provisional protocol: statistical predictors of implant failure.

    Science.gov (United States)

    Kinsel, Richard P; Liss, Mindy

    2007-01-01

    The purpose of this retrospective study was to evaluate the effects of implant dimensions, surface treatment, location in the dental arch, numbers of supporting implant abutments, surgical technique, and generally recognized risk factors on the survival of a series of single-stage Straumann dental implants placed into edentulous arches using an immediate loading protocol. Each patient received between 4 and 18 implants in one or both dental arches. Periapical radiographs were obtained over a 2- to 10-year follow-up period to evaluate crestal bone loss following insertion of the definitive metal-ceramic fixed prostheses. Univariate tests for failure rates as a function of age ( or = 60 years), gender, smoking, bone grafting, dental arch, surface type, anterior versus posterior, number of implants per arch, and surgical technique were made using Fisher exact tests. The Cochran-Armitage test for trend was used to evaluate the presence of a linear trend in failure rates regarding implant length and implant diameter. Logistic regression modeling was used to determine which, if any, of the aforementioned factors would predict patient and implant failure. A significance criterion of P = .05 was utilized. Data were collected for 344 single-stage implants placed into 56 edentulous arches (39 maxillae and 17 mandibles) of 43 patients and immediately loaded with a 1-piece provisional fixed prosthesis. A total of 16 implants failed to successfully integrate, for a survival rate of 95.3%. Increased rates of failure were associated with reduced implant length, placement in the posterior region of the jaw, increased implant diameter, and surface treatment. Implant length emerged as the sole significant predictor of implant failure. In this retrospective analysis of 56 consecutively treated edentulous arches with multiple single-stage dental implants loaded immediately, reduced implant length was the sole significant predictor of failure.

  16. A Cost-Effective Power Ramp-Rate Control Strategy for Single-Phase Two-Stage Grid-Connected Photovoltaic Systems

    DEFF Research Database (Denmark)

    Sangwongwanich, Ariya; Yang, Yongheng; Blaabjerg, Frede

    2016-01-01

    In the case of a wide-scale adoption of grid-connected Photovoltaic (PV) systems, more fluctuated power will be injected into the grid due to the intermittency of solar PV energy. A sudden change in the PV power can potentially induce grid voltage fluctuations, and thus challenge the stability......-point. Experiments conducted on a 3-kW single-phase two-stage grid-connected PV system have verified that the proposed solution can accomplish fast dynamics, high accuracy, and high robustness in the power ramp-rate control for PV systems....

  17. Safety and efficacy of staged retrograde intrarenal surgery for large stone burden of renal stones in selected patients: A single-center experience

    Directory of Open Access Journals (Sweden)

    Cheng-Feng Lin

    2017-06-01

    Conclusion: To the best of our knowledge, RIRS for large renal stone manipulation is an effective and safe treatment modality currently. In our study, the single RIRS SFR was superior to PNL or SWL even when the stone burden was between 2.0 cm and 3.0 cm (80.2%. For those patients whose stone burden was over 3.0 cm or for those with comorbidities, staged RIRS resulted in a lower complication rate, reduced hospital stay, and better SFR (76.5%.

  18. Tumour burden in early stage Hodgkin's disease: the single most important prognostic factor for outcome after radiotherapy

    DEFF Research Database (Denmark)

    Specht, L; Nordentoft, A M; Cold, Søren

    1987-01-01

    One hundred and forty-two patients with Hodgkin's disease PS I or II were treated with total or subtotal nodal irradiation as part of a prospective randomized trial in the Danish National Hodgkin Study during the period 1971-83. They were followed till death or--at the time of this analysis......--from 15 to 146 months after initiation of therapy. The initial tumour burden of each patient was assessed, combining tumour size of each involved region and number of regions involved. Tumour burden thus assessed proved to be the single most important prognostic factor with regard to disease free survival...

  19. One stage revision single-bundle anterior cruciate ligament reconstruction with impacted morselized bone graft following a failed double-bundle reconstruction

    Directory of Open Access Journals (Sweden)

    Ho Jong Ra

    2017-01-01

    Full Text Available Although double-bundle anterior cruciate ligament (ACL reconstruction has theoretical benefits such as more accurate reproduction of ACL anatomy, it is technically more demanding surgery. This report describes the case of a one stage revision single-bundle ACL reconstruction after primary double-bundle ACL reconstruction. A professional dancer had an ACL previously reconstructed with a double-bundle technique, but the femoral tunnels were malpositioned resulting in residual laxity and rotational instability. The previous femoral tunnel positions were vertical and widened. The previous vertical tunnels were filled with impacted bone graft and a revision single-bundle ACL reconstruction was performed via the new femoral tunnel with a 2 O'clock position between the previous two tunnels. After 10 months of postoperative rehabilitation, the patient returned to professional dancing with sound bony union and without any residual instability.

  20. Single Stage String Inverter for Gridconnected Photovoltaic System with Modified Perturb and Observe (P&O Fuzzy Logic Control(FLC-based MPPT Technique

    Directory of Open Access Journals (Sweden)

    S.Z.Mohammad Noor

    2016-06-01

    Full Text Available This paper presents an implementation of Single-phase Single stage String inverter for Grid connected Photovoltaic (PV system. The proposed system uses Modified Perturb and Observe (P&O algorithm implemented using Fuzzy Logic Control (FLC as Maximum Power Point Tracking (MPPT. The inverter is designed for 340W system using two series of STP170s24/Ac PV modules. The MPPT unit keeps tracking the maximum power from the PV array by changing the modulation index and the phase angle of inverter’s output voltage. The simulation model is developed using Matlab/Simulink to evaluate the performance of the converter. Selected experimental results are also presented in this paper.

  1. Accelerated hypofractionated three-dimensional conformal radiation therapy (3 Gy/fraction) combined with concurrent chemotherapy for patients with unresectable stage III non-small cell lung cancer: preliminary results of an early terminated phase II trial.

    Science.gov (United States)

    Ren, Xiao-Cang; Wang, Quan-Yu; Zhang, Rui; Chen, Xue-Ji; Wang, Na; Liu, Yue-E; Zong, Jie; Guo, Zhi-Jun; Wang, Dong-Ying; Lin, Qiang

    2016-04-23

    Increasing the biological effective dose (BED) of radiotherapy for non-small cell lung cancer (NSCLC) can increase local control rates and improve overall survival. Compared with conventional fractionated radiotherapy, accelerated hypofractionated radiotherapy can yield higher BED, shorten the total treatment time, and theoretically obtain better efficacy. However, currently, there is no optimal hypofractionated radiotherapy regimen. Based on phase I trial results, we performed this phase II trial to further evaluate the safety and preliminary efficacy of accelerated hypofractionated three-dimensional conformal radiation therapy(3-DCRT) combined with concurrent chemotherapy for patients with unresectable stage III NSCLC. Patients with previously untreated unresectable stage III NSCLC received 3-DCRT with a total dose of 69 Gy, delivered at 3 Gy per fraction, once daily, five fractions per week, completed within 4.6 weeks. At the same time, platinum doublet chemotherapy was applied. After 12 patients were enrolled in the group, the trial was terminated early. There were five cases of grade III radiation esophagitis, of which four cases completed the radiation doses of 51 Gy, 51 Gy, 54 Gy, and 66 Gy, and one case had 16 days of radiation interruption. The incidence of grade III acute esophagitis in patients receiving an irradiation dose per fraction ≥2.7 Gy on the esophagus was 83.3% (5/6). The incidence of symptomatic grade III radiation pneumonitis among the seven patients who completed 69 Gy according to the plan was 28.6% (2/7). The median local control (LC) and overall survival (OS) were not achieved; the 1-year LC rate was 59.3%, and the 1-year OS rate was 78.6%. For unresectable stage III NSCLC, the accelerated hypofractionated radiotherapy with a total dose of 69 Gy (3 Gy/f) combined with concurrent chemotherapy might result in severe radiation esophagitis and pneumonitis to severely affect the completion of the radiotherapy. Therefore, we considered that

  2. A Collaborative Analysis Tool for Integrated Hypersonic Aerodynamics, Thermal Protection Systems, and RBCC Engine Performance for Single Stage to Orbit Vehicles

    Science.gov (United States)

    Stanley, Thomas Troy; Alexander, Reginald; Landrum, Brian

    2000-01-01

    Presented is a computer-based tool that connects several disciplines that are needed in the complex and integrated design of high performance reusable single stage to orbit (SSTO) vehicles. Every system is linked to every other system, as is the case of SSTO vehicles with air breathing propulsion, which is currently being studied by NASA. An RBCC propulsion system integrates airbreathing and rocket propulsion into a single engine assembly enclosed within a cowl or duct. A typical RBCC propulsion system operates as a ducted rocket up to approximately Mach 3. Then there is a transition to a ramjet mode for supersonic-to-hypersonic acceleration. Around Mach 8 the engine transitions to a scramjet mode. During the ramjet and scramjet modes, the integral rockets operate as fuel injectors. Around Mach 10-12 (the actual value depends on vehicle and mission requirements), the inlet is physically closed and the engine transitions to an integral rocket mode for orbit insertion. A common feature of RBCC propelled vehicles is the high degree of integration between the propulsion system and airframe. At high speeds the vehicle forebody is fundamentally part of the engine inlet, providing a compression surface for air flowing into the engine. The compressed air is mixed with fuel and burned. The combusted mixture must be expanded to an area larger than the incoming stream to provide thrust. Since a conventional nozzle would be too large, the entire lower after body of the vehicle is used as an expansion surface. Because of the high external temperatures seen during atmospheric flight, the design of an airbreathing SSTO vehicle requires delicate tradeoffs between engine design, vehicle shape, and thermal protection system (TPS) sizing in order to produce an optimum system in terms of weight (and cost) and maximum performance. To adequately determine the performance of the engine/vehicle, the Hypersonic Flight Inlet Model (HYFIM) module was designed to interface with the RBCC

  3. Effect of Die Head Temperature at Compounding Stage on the Degradation of Linear Low Density Polyethylene/Plastic Film Waste Blends after Accelerated Weathering

    Directory of Open Access Journals (Sweden)

    S. M. Al-Salem

    2016-01-01

    Full Text Available Accelerated weathering test was performed on blends of linear low density polyethylene (LLDPE and plastic film waste constituting the following percentages of polyolefin polymers (wt.%: LLDPE (46%, low density polyethylene (LDPE, 51%, high density polyethylene (HDPE, 1%, and polypropylene (PP, 2%. Compounded blends were evaluated for their mechanical and physical (optical properties. The impact of photodegradation on the formulated blends was studied, and loss of mechanical integrity was apparent with respect to both the exposure duration to weathering and waste content. The effect of processing conditions, namely, the die head temperature (DHT of the blown-film assembly used, was investigated in this work. It was witnessed that surpassing the melting point of the blends constituting polymers did not always result in a synergistic behaviour between polymers. This was suspected to be due to the loss of amorphous region that polyolefin polymers get subjected to with UV exposure under weathering conditions and the effect of the plastic waste constituents. The total change in colour (ΔE did not change with respect to DHT or waste content due to rapid change degradation on the material’s surface. Haze (% and light transmission (% decreased with the increase in waste content which was attributed to lack of miscibility between constituting polymers.

  4. Clinical characteristics and outcome of patients with stage III esophageal carcinoma: a single-center experience from Turkey.

    Science.gov (United States)

    Ugur, Vahide I; Kara, Sakire P; Kucukplakci, Bulent; Demirkasimoglu, Taciser; Misirlioglu, Cem; Ozgen, Aytul; Elgin, Yesim; Sanri, Ergun; Altundag, Kadri; Ozdamar, Nadi

    2008-01-01

    Esophageal carcinoma is an extremely deadly disease, and prognosis is poor. We retrospectively evaluated stage III esophageal carcinoma patients in our center. Median age of the patients was 52. Men to women ratio were 3/1. Epidermoid carcinoma was the major histology. Incidence of esophageal carcinoma was higher in the distal and middle third of the esophagus. In 19 patients tumor size was more than 5 cm. In total of 17 of the patients were operated. About 58 patients were irradiated. About 45 of the patients were irradiated with curative intent, 31 of them were primarily irradiated and 14 of them were irradiated postoperatively. Only 13 of the patients received concurrent chemoradiotherapy. Overall 1, 2, 3, and 4 year survival rates were 38.9%, 11.1%, 5.6%, and %1.9, respectively and median survival was 12 months. Median survival for tumors located in cervical esophageal, middle esophagus, and distal esophagus were 23, 8, and 14 months, respectively. One, 2, 3, 4 year survival rates of operated patients were 58.8%, 29.4%, 17.6%, 5.9%, respectively and median survival was 23 months. For inoperable patients 1 and 2 year survival rates were 29.7% and 2.7% and median survival was 8 months. Differences between operable and inoperable patients were statistically significant (P: 0.0003). One, 2, 3, 4 years survival results of patients treated with surgery and postoperative radiotherapy was 62.5%, 25%, 12.5%, 12.5% and median survival was 21 months, 1, 2, 3, 4 years survival results of patients treated with surgery and concurrent chemoradiotherapy was 55.6%, 33.3%, 22.2%, and 0% and median survival was 27 months. There was no statistically significant difference between groups (P: 0.5390). During the therapy, disphagia was the major side effect observed in seven patients. Fatigue, pain, and mild weight loss were the other side effects. Three patients could not tolerate the treatment and left the therapy. We demonstrated that stage III esophageal carcinoma is an extremely

  5. Single-Fraction Carbon-Ion Radiation Therapy for Patients 80 Years of Age and Older With Stage I Non-Small Cell Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Karube, Masataka, E-mail: mstk117@gmail.com [Research Center Hospital for Charged Particle Therapy, National Institute of Radiological Sciences, Chiba (Japan); Department of Radiology, The University of Tokyo Hospital, Tokyo (Japan); Yamamoto, Naoyoshi; Nakajima, Mio [Research Center Hospital for Charged Particle Therapy, National Institute of Radiological Sciences, Chiba (Japan); Yamashita, Hideomi; Nakagawa, Keiichi [Department of Radiology, The University of Tokyo Hospital, Tokyo (Japan); Miyamoto, Tadaaki; Tsuji, Hiroshi [Research Center Hospital for Charged Particle Therapy, National Institute of Radiological Sciences, Chiba (Japan); Fujisawa, Takehiko [Chiba Foundation for Health Promotion and Disease Prevention, Chiba (Japan); Kamada, Tadashi [Research Center Hospital for Charged Particle Therapy, National Institute of Radiological Sciences, Chiba (Japan)

    2016-05-01

    Purpose: In an aging society, many senior citizens want less invasive treatment because of potential medical complications. The National Institute of Radiological Sciences has started to treat stage I lung cancer with single-fraction carbon-ion radiation therapy (CIRT) as a dose escalation prospective phase 1/2 trial. We evaluated the efficacy and safety of CIRT for patients 80 years of age and older, undergoing single-fraction CIRT. Methods and Materials: Peripheral non-small cell lung cancer patients who were treated with single-fraction CIRT were prospectively followed. We analyzed the data from among these patients 80 years of age and older. Results: There were 70 patients. Median age was 83 years (range: 80-89) and median follow-up period was 42.7 months (range: 12-128 months). Three-year local control, cause-specific survival, and overall survival rates were 88.0%, 81.6%, and 72.4%, respectively. Five-year local control, cause-specific survival, and overall survival rates were 85.8%, 64.9%, and 39.7%, respectively. There were no adverse effects higher than grade 2 either in the acute or late phase in terms of skin and lung. Analgesic agents were necessary for only 5 patients (7.1%), to relieve muscular or rib fracture pain caused by irradiation. Conclusions: Single-fraction CIRT was low-risk and effective, even for the elderly.

  6. Malnutrition, inflamation and atherosclerosis (MIA syndrome) in patients with end stage renal disease on maintenance hemodialysis (a single centre experience).

    Science.gov (United States)

    Allawi, Ali Abdulmajid Dyab

    2017-09-21

    Inflammation and malnutrition play an important role in endothelial dysfunction, atherosclerosis and excessive cardiovascular morbidity and mortality in ESRD patients AIM OF THE STUDY: The primary objective is to determine the prevalence of inflammation, malnutrition and atherosclerosis in patients on maintenance haemodialysis. Secondary objective was to determine the association for atherosclerosis with inflammation and malnutrition. One hundred and one adult patients with end stage renal disease on maintenance haemodialysis who are met with the exclusion criteria were enrolled in this cross sectional study from haemodialysis unit of Baghdad teaching hospital over the period of July/2015 - June 2016. All patients were thoroughly examined and many variables were evaluated (age, gender, blood pressure, diabetes mellitus, serum lipid profile, smoking habits, serum albumin, CRP, calcium, Phosphate, Parathyroid hormone and haemoglobin measurements). All patients underwent a carotid Doppler ultrasound study. Atherosclerosis was present in 65.3%: 58.4% of patients had malnutrition and 43.6% had inflammation. The association for atherosclerosis and high CRP and low serum albumin is strong and independent of other atherosclerosis risk factors. There is significant inverse and independent correlation between CRP and albumin. Inflammation (high serum CRP) and malnutrition (low serum albumin) in patients on haemodialysis are significantly associated with carotid atherosclerosis. Inflammation was more prevalent in the malnourished patients than in those with normal nutritional status. Copyright © 2017 Diabetes India. Published by Elsevier Ltd. All rights reserved.

  7. Experiments of an intense H{sup -} ion beam acceleration

    Energy Technology Data Exchange (ETDEWEB)

    Ando, A.; Takeiri, Y.; Kaneko, O.; Oka, Y.; Tsumori, K.; Asano, E.; Kawamoto, T.; Akiyama, R.; Kuroda, T.

    1995-08-01

    An intense H{sup -} beam of a single beamlet is extracted from a large multicusp plasma source operated with cesium seeding. The H{sup -} beams are accelerated up to 100keV by a single-stage or a two-stage electrode system. Spatial profiles of the beams are measured calorimetrically and a minimum beam divergence angle of 5mrad is achieved at a H{sup -} current density of 30mA/cm{sup 2} with a beam energy of 100keV. A ratio of an acceleration current to a H{sup -} current increases abruptly when a H{sup -} current saturates in the space charge limited region. This enhancement is mainly due to secondary electrons caused by the intersection of H{sup -} beams with an extraction grid. When an operating gas pressure decreases, the ratio of the acceleration current to the H{sup -} current decreases. This is related to a stripping loss of H{sup -} ions in the electrodes. A beam divergence angle becomes minimum when a ratio of V{sub acc} to V{sub ext} is set at a optimum value of 1.6 in the single-stage acceleration. This ratio is almost the same as that in the double-stage acceleration, where the optimum ratio of E{sub acc1}/E{sub ext} is 1.5. In the optimum E{sub acc1}/E{sub ext} ratio the divergence angle is not affected by V{sub acc2}. The divergence angle can be reduced by changing V{sub acc2} even if the ratio of E{sub acc1}/E{sub ext} is not optimized. The beam steering effect by permanent magnets buried in an extraction grid is observed in nine beamlets experiments. A simple calculation of a single particle trajectory gives a good approximation of the beam deflection angle. (author).

  8. Multi-staging for extraction of cesium from nitric acid by a single liquid-liquid countercurrent centrifugal extractor with Taylor vortices

    International Nuclear Information System (INIS)

    Nakase, Masahiko; Kinuhata, Hiroshi; Takeshita, Kenji

    2013-01-01

    Fission products that emit considerable decay heat and radioactivity, such as 137 Cs, have a large impact on waste management. Small and high-performance extractor is desirable for separating such nuclei. In this study, we implemented the continuous extraction of Cs from nitric acid in a single liquid-liquid countercurrent centrifugal extractor with Taylor Vortices by calix arene-bis(t-octylbenzo-crown-6)(BOBCalixC6) as an extractant with trioctylamine(TOA) as a suppressant and with 1-(2,2,3,3-tetrafluoropropoxy)-3-(4-sec-butylphenoxy)-2-propanol (Cs-7SB) as a phase modifier. Because of slow extraction kinetics of this process, extraction with multiple theoretical stages by just replacing conventional extractors into the single centrifugal extractor is difficult. Hence, we improved the dispersion of organic phase by an inner rotor made of lipophilic epoxy resin and elevating the solution temperature to lower the viscosity. Higher temperature was not appropriate from the aspect of chemical equilibrium in this process, but extraction with multiple theoretical stages was found to be possible. (author)

  9. Effects of sludge recirculation rate and mixing time on performance of a prototype single-stage anaerobic digester for conversion of food wastes to biogas and energy recovery.

    Science.gov (United States)

    Ratanatamskul, Chavalit; Saleart, Tawinan

    2016-04-01

    Food wastes have been recognized as the largest waste stream and accounts for 39.25 % of total municipal solid waste in Thailand. Chulalongkorn University has participated in the program of in situ energy recovery from food wastes under the Ministry of Energy (MOE), Thailand. This research aims to develop a prototype single-stage anaerobic digestion system for biogas production and energy recovery from food wastes inside Chulalongkorn University. Here, the effects of sludge recirculation rate and mixing time were investigated as the main key parameters for the system design and operation. From the results obtained in this study, it was found that the sludge recirculation rate of 100 % and the mixing time of 60 min per day were the most suitable design parameters to achieve high efficiencies in terms of chemical oxygen demand (COD), total solids (TS), and total volatile solid (TVS) removal and also biogas production by this prototype anaerobic digester. The obtained biogas production was found to be 0.71 m(3)/kg COD and the composition of methane was 61.6 %. Moreover, the efficiencies of COD removal were as high as 82.9 % and TVS removal could reach 83.9 % at the optimal condition. Therefore, the developed prototype single-stage anaerobic digester can be highly promising for university canteen application to recover energy from food wastes via biogas production.

  10. Reactive Power Control of Single-Stage Three-Phase Photovoltaic System during Grid Faults Using Recurrent Fuzzy Cerebellar Model Articulation Neural Network

    Directory of Open Access Journals (Sweden)

    Faa-Jeng Lin

    2014-01-01

    Full Text Available This study presents a new active and reactive power control scheme for a single-stage three-phase grid-connected photovoltaic (PV system during grid faults. The presented PV system utilizes a single-stage three-phase current-controlled voltage-source inverter to achieve the maximum power point tracking (MPPT control of the PV panel with the function of low voltage ride through (LVRT. Moreover, a formula based on positive sequence voltage for evaluating the percentage of voltage sag is derived to determine the ratio of the injected reactive current to satisfy the LVRT regulations. To reduce the risk of overcurrent during LVRT operation, a current limit is predefined for the injection of reactive current. Furthermore, the control of active and reactive power is designed using a two-dimensional recurrent fuzzy cerebellar model articulation neural network (2D-RFCMANN. In addition, the online learning laws of 2D-RFCMANN are derived according to gradient descent method with varied learning-rate coefficients for network parameters to assure the convergence of the tracking error. Finally, some experimental tests are realized to validate the effectiveness of the proposed control scheme.

  11. A simulation study on performance evaluation of single-stage LiBr–H2O vapor absorption heat pump for chip cooling

    Directory of Open Access Journals (Sweden)

    Manu S.

    2016-12-01

    Full Text Available The growth of Lithium Bromide–Water (LiBr–H2O absorption based heat pump is encouraged for the necessity of extracting high heat from the electronic chips. This paper presents a simulation study of single-stage LiBr–H2O vapor absorption heat pump for chip cooling. In this study, a detailed thermodynamic analysis of the single-stage LiBr–H2O vapor absorption heat pump for chip cooling in the nonexistence of solution heat exchanger was performed and a user-friendly graphical user interface (GUI package including visual components was developed by using MATlab (2008b. The influence of chip temperature on COP (Coefficient of Performance, flow rates and conductance was examined by using the developed package. The model is validated by using the values available in the literature and indicates that there is a greater reduction in the absorber load. The influence of chip temperature on the performance and thermal loads of individual components was studied and it was concluded that, COP increases from 0.7145 to 0.8421 with an increase in chip temperature.

  12. Proton-driven plasma wakefield acceleration: a path to the future of high-energy particle physics

    CERN Document Server

    Assmann, R.; Bohl, T.; Bracco, C.; Buttenschon, B.; Butterworth, A.; Caldwell, A.; Chattopadhyay, S.; Cipiccia, S.; Feldbaumer, E.; Fonseca, R.A.; Goddard, B.; Gross, M.; Grulke, O.; Gschwendtner, E.; Holloway, J.; Huang, C.; Jaroszynski, D.; Jolly, S.; Kempkes, P.; Lopes, N.; Lotov, K.; Machacek, J.; Mandry, S.R.; McKenzie, J.W.; Meddahi, M.; Militsyn, B.L.; Moschuering, N.; Muggli, P.; Najmudin, Z.; Noakes, T.C.Q.; Norreys, P.A.; Oz, E.; Pardons, A.; Petrenko, A.; Pukhov, A.; Rieger, K.; Reimann, O.; Ruhl, H.; Shaposhnikova, E.; Silva, L.O.; Sosedkin, A.; Tarkeshian, R.; Trines, R.M.G.N.; Tuckmantel, T.; Vieira, J.; Vincke, H.; Wing, M.; Xia, G.

    2014-01-01

    New acceleration technology is mandatory for the future elucidation of fundamental particles and their interactions. A promising approach is to exploit the properties of plasmas. Past research has focused on creating large-amplitude plasma waves by injecting an intense laser pulse or an electron bunch into the plasma. However, the maximum energy gain of electrons accelerated in a single plasma stage is limited by the energy of the driver. Proton bunches are the most promising drivers of wakefields to accelerate electrons to the TeV energy scale in a single stage. An experimental program at CERN -- the AWAKE experiment -- has been launched to study in detail the important physical processes and to demonstrate the power of proton-driven plasma wakefield acceleration. Here we review the physical principles and some experimental considerations for a future proton-driven plasma wakefield accelerator.

  13. Reduction of the divergence angle of an incident beam to enhance the demagnification factor of a two-stage acceleration lens in a gas ion nanobeam system of several tens of keV

    Science.gov (United States)

    Ishii, Yasuyuki; Kojima, Takuji

    2018-04-01

    The demagnification factor of a two-stage acceleration lens in a gas ion nanobeam system that produces ion beams with energies in the order of 10 keV was enhanced in this study so that a hydrogen ion beam with a diameter of 115 nm could be produced. The reduction of the divergence angle of the incident beam into the two-stage acceleration lens is the effective method for enhancing the demagnification factor. The divergence angle has been gradually reduced by firstly introducing the preacceleration electrodes to control the divergence angle, namely divergence-angle-control electrodes, and secondly replacing an anode with a modified anode that possesses a Pierce electrode, both of which were in an ion source directly connected to the lens. In this study, the divergence angle of less than 3.6 × 10-4 rad that was previously used to produce a 160-nm hydrogen ion beam with the energy of 46 keV by the above procedure was numerically determined using an ion beam extraction simulation code. The determined minimum divergence angle of the incident ion beam was calculated to be 2.0 × 10-4 rad, which was about half of the previously obtained divergence angle; this was used to experimentally form a hydrogen beam with a diameter of 115 ± 10 nm and the energy of 47 keV. The demagnification factor was estimated to be 1,739 using the newly formed hydrogen beam, which was similar to the simulation result.

  14. Monolithic Composite “Pressure + Acceleration + Temperature + Infrared” Sensor Using a Versatile Single-Sided “SiN/Poly-Si/Al” Process-Module

    Science.gov (United States)

    Ni, Zao; Yang, Chen; Xu, Dehui; Zhou, Hong; Zhou, Wei; Li, Tie; Xiong, Bin; Li, Xinxin

    2013-01-01

    We report a newly developed design/fabrication module with low-cost single-sided “low-stress-silicon-nitride (LS-SiN)/polysilicon (poly-Si)/Al” process for monolithic integration of composite sensors for sensing-network-node applications. A front-side surface-/bulk-micromachining process on a conventional Si-substrate is developed, featuring a multifunctional SiN/poly-Si/Al layer design for diverse sensing functions. The first “pressure + acceleration + temperature + infrared” (PATIR) composite sensor with the chip size of 2.5 mm × 2.5 mm is demonstrated. Systematic theoretical design and analysis methods are developed. The diverse sensing components include a piezoresistive absolute-pressure sensor (up to 700 kPa, with a sensitivity of 49 mV/MPa under 3.3 V supplied voltage), a piezoresistive accelerometer (±10 g, with a sensitivity of 66 μV/g under 3.3 V and a −3 dB bandwidth of 780 Hz), a thermoelectric infrared detector (with a responsivity of 45 V/W and detectivity of 3.6 × 107 cm·Hz1/2/W) and a thermistor (−25–120 °C). This design/fabrication module concept enables a low-cost monolithically-integrated “multifunctional-library” technique. It can be utilized as a customizable tool for versatile application-specific requirements, which is very useful for small-size, low-cost, large-scale sensing-network node developments. PMID:23325169

  15. Monolithic Composite “Pressure + Acceleration + Temperature + Infrared” Sensor Using a Versatile Single-Sided “SiN/Poly-Si/Al” Process-Module

    Directory of Open Access Journals (Sweden)

    Xinxin Li

    2013-01-01

    Full Text Available We report a newly developed design/fabrication module with low-cost single-sided “low-stress-silicon-nitride (LS-SiN/polysilicon (poly-Si/Al” process for monolithic integration of composite sensors for sensing-network-node applications. A front-side surface-/bulk-micromachining process on a conventional Si-substrate is developed, featuring a multifunctional SiN/poly-Si/Al layer design for diverse sensing functions. The first “pressure + acceleration + temperature + infrared” (PATIR composite sensor with the chip size of 2.5 mm × 2.5 mm is demonstrated. Systematic theoretical design and analysis methods are developed. The diverse sensing components include a piezoresistive absolute-pressure sensor (up to 700 kPa, with a sensitivity of 49 mV/MPa under 3.3 V supplied voltage, a piezoresistive accelerometer (±10 g, with a sensitivity of 66 μV/g under 3.3 V and a −3 dB bandwidth of 780 Hz, a thermoelectric infrared detector (with a responsivity of 45 V/W and detectivity of 3.6 × 107 cm·Hz1/2/W and a thermistor (−25–120 °C. This design/fabrication module concept enables a low-cost monolithically-integrated “multifunctional-library” technique. It can be utilized as a customizable tool for versatile application-specific requirements, which is very useful for small-size, low-cost, large-scale sensing-network node developments.

  16. Laser accelerators

    International Nuclear Information System (INIS)

    Willis, W.J.

    1977-01-01

    A brief discussion is given on the feasibility of using lasers to accelerate particle beams. A rough theory of operation is developed, and numerical results are obtained for an example equivalent to the Fermilab Accelerator

  17. Administering Multiple Injectable Vaccines During a Single Visit-Summary of Findings From the Accelerated Introduction of Inactivated Polio Vaccine Globally.

    Science.gov (United States)

    Dolan, Samantha B; Patel, Manish; Hampton, Lee M; Burnett, Eleanor; Ehlman, Daniel C; Garon, Julie; Cloessner, Emily; Chmielewski, Elizabeth; Hyde, Terri B; Mantel, Carsten; Wallace, Aaron S

    2017-07-01

    largely from developed countries. Parental acceptance of multiple injections was associated with a positive provider recommendation to the caregiver. Findings of the systematic review identified that the intramuscular route is preferred over the subcutaneous route for vaccine administration and that the vastus lateralis muscle is preferred over the deltoid muscle for intramuscular injections. Recommendations on vaccine spacing and procedural preparedness were based on practical necessities, but comparative evidence was not identified. During 2013-2015, 85 countries added IPV to their immunization schedules, 46 (55%) of which adopted a schedule resulting in 3 injectable vaccines being administered in a single visit. The multiple-injection experience identified gaps in guidance for future vaccine introductions. Global partner organizations quickly mobilized to assess, document, and communicate the existing global experience on multiple-injection visits. This evidence-based approach provided reassurance to opinion leaders, health workers, and professional societies, thus encouraging uptake of IPV as a second or third injection in an accelerated manner globally. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.

  18. Source identification of nitrous oxide emission pathways from a single-stage nitritation-anammox granular reactor

    KAUST Repository

    Ali, Muhammad

    2016-06-16

    Nitrous oxide (N2O) production pathway in a signal-stage nitritation-anammox sequencing batch reactor (SBR) was investigated based on a multilateral approach including real-time N2O monitoring, N2O isotopic composition analysis, and in-situ analyses of spatial distribution of N2O production rate and microbial populations in granular biomass. N2O emission rate was high in the initial phase of the operation cycle and gradually decreased with decreasing NH4+ concentration. The average emission of N2O was 0.98 ± 0.42% and 1.35 ± 0.72% of the incoming nitrogen load and removed nitrogen, respectively. The N2O isotopic composition analysis revealed that N2O was produced via NH2OH oxidation and NO2− reduction pathways equally, although there is an unknown influence from N2O reduction and/or anammox N2O production. However, the N2O isotopomer analysis could not discriminate the relative contribution of nitrifier denitrification and heterotrophic denitrification in the NO2− reduction pathway. Various in-situ techniques (e.g. microsensor measurements and FISH (fluorescent in-situ hybridization) analysis) were therefore applied to further identify N2O producers. Microsensor measurements revealed that approximately 70% of N2O was produced in the oxic surface zone, where nitrifiers were predominantly localized. Thus, NH2OH oxidation and NO2 reduction by nitrifiers (nitrifier-denitrification) could be responsible for the N2O production in the oxic zone. The rest of N2O (ca. 30%) was produced in the anammox bacteria-dominated anoxic zone, probably suggesting that NO2− reduction by coexisting putative heterotrophic denitrifiers and some other unknown pathway(s) including the possibility of anammox process account for the anaerobic N2O production. Further study is required to identify the anaerobic N2O production pathways. Our multilateral approach can be useful to quantitatively examine the relative contributions of N2O production pathways. Good understanding of the key N2O

  19. Single-stage multilevel soft-tissue surgery in the lower limbs with spastic cerebral palsy: Experience from a rehabilitation unit

    Directory of Open Access Journals (Sweden)

    Gupta Anupam

    2008-01-01

    Full Text Available Background: To assess the effect of single-stage multilevel soft-tissue surgery (Single Event Multiple Level Resections, SEMLR on deformities and locomotion in patients with cerebral palsy (CP with static contracture(s in lower limbs. Patients and Methods: Study included 34 patients (M:F, 23:11 with mean age of 9.53 ± 3.92 years (4-16 years. Among them 22 had diplegia and four each had quadriplegia and right and left hemiplegia. Fourteen patients (41.2% had their intelligence quotient (IQ in the normal range (IQ ≥ 80, while others had mental retardation (MR of varying severity: borderline MR (IQ = 70-79 in 12, mild MR (IQ = 50-69 in 5, and moderate MR (IQ = 35-49 in patients 3. All patients underwent surgery (total number of procedures 153, average 4.5 procedures/patient over a period of 30 months (April 2005 to September 2007. Improvement in functional abilities and locomotion was assessed using Gross Motor Functional Classification Scale (GMFCS scores and by physical examination. Results: Significant improvement in function was observed ( P = 0.000 after surgery when comparing the preoperative and postoperative GMFCS scores. All patients were maintaining ambulation at a mean follow-up duration of 13.12 ± 6.07 months (3-24 months, with five patients using knee-ankle-foot orthoses (KAFO, 22 using ankle-foot orthoses (AFO, and six patients using knee gaiters. Sixteen patients were using walker, and two were using crutches as assistive devices. Conclusion: This study suggests that CP patients with good trunk control and static contractures at multiple joints in the lower limbs can be made ambulant with single-stage multilevel soft-tissue surgery. It has to be a team effort of the surgeon and the rehabilitation team in the postoperative period for the attainment of satisfactory goal.

  20. Urochordate ascidians possess a single isoform of Aurora kinase that localizes to the midbody via TPX2 in eggs and cleavage stage embryos.

    Directory of Open Access Journals (Sweden)

    Celine Hebras

    Full Text Available Aurora kinases are key proteins found throughout the eukaryotes that control mitotic progression. Vertebrate Aurora-A and B kinases are thought to have evolved from a single Aurora-kinase isoform closest to that found in present day urochordates. In urochordate ascidians Aurora binds both TPX2 (a vertebrate AURKA partner and INCENP (a vertebrate AURKB partner and localizes to centrosomes and spindle microtubules as well as chromosomes and midbody during both meiosis and mitosis. Ascidian Aurora also displays this localization pattern during mitosis in echinoderms, strengthening the idea that non-vertebrate deuterostomes such as the urochordates and echinoderms possess a single form of Aurora kinase that has properties of vertebrate Aurora-kinase A and B. In the ascidian, TPX2 localizes to the centrosome and the spindle poles also as in vertebrates. However, we were surprised to find that TPX2 also localized strongly to the midbody in ascidian eggs and embryos. We thus examined more closely Aurora localization to the midbody by creating two separate point mutations of ascidian Aurora predicted to perturb binding to TPX2. Both forms of mutated Aurora behaved as predicted: neither localized to spindle poles where TPX2 is enriched. Interestingly, neither form of mutated Aurora localized to the midbody where TPX2 is also enriched, suggesting that ascidian Aurora midbody localization required TPX2 binding in ascidians. Functional analysis revealed that inhibition of Aurora kinase with a pharmacological inhibitor or with a dominant negative kinase dead form of Aurora caused cytokinesis failure and perturbed midbody formation during polar body extrusion. Our data support the view that vertebrate Aurora-A and B kinases evolved from a single non-vertebrate deuterostome ancestor. Moreover, since TPX2 localizes to the midbody in ascidian eggs and cleavage stage embryos it may be worthwhile re-assessing whether Aurora A kinase or TPX2 localize to the midbody

  1. Combined inflatable penile prosthesis-artificial urinary sphincter implantation: no increased risk of adverse events compared to single or staged device implantation.

    Science.gov (United States)

    Segal, Robert L; Cabrini, Mercelo R; Harris, Elaine D; Mostwin, Jacek L; Bivalacqua, Trinity J; Burnett, Arthur L

    2013-12-01

    Little data exist on the outcome of combined inflatable penile prosthesis and artificial urinary sphincter insertion for erectile dysfunction and stress urinary incontinence. We assessed patient outcomes for combined vs single device implantation at a single institution. We retrospectively reviewed the records of all patients who underwent inflatable penile prosthesis and artificial urinary sphincter insertion at our hospital from January 2000 to December 2011. A total of 55 combined procedures were performed compared to the single insertion of 336 inflatable penile prostheses and 279 artificial urinary sphincters. The surgical approach consisted of penoscrotal incisions for inflatable penile prostheses and transperineal incisions for artificial urinary sphincter cuff placement with a secondary lower abdominal incision for reservoir placement. Men treated with combined implantation had greater mean age and were at greater risk for prostate cancer diagnosis and treatment, and at lesser risk for Peyronie disease than men who received an inflatable penile prosthesis alone (each pprosthesis alone and the AUS alone (mean 218.1 vs 145.9 and 114.7 minutes, respectively, p0.05). Combined inflatable penile prosthesis-artificial urinary sphincter implantation and staged prosthesis implantation are feasible without an increased risk of adverse outcomes compared to implantation of a single prosthesis. Patients with concomitant erectile dysfunction and stress urinary incontinence should be counseled about the possible advantages of this surgical option, which include a single anesthesia event and faster resumption of sexual activity and urinary control. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  2. Stage-independent, single lead EEG sleep spindle detection using the continuous wavelet transform and local weighted smoothing

    Directory of Open Access Journals (Sweden)

    Athanasios eTsanas

    2015-04-01

    Full Text Available Sleep spindles are critical in characterizing sleep and have been associated with cognitive function and pathophysiological assessment. Typically, their detection relies on the subjective and time-consuming visual examination of electroencephalogram (EEG signal(s by experts, and has led to large inter-rater variability as a result of poor definition of sleep spindle characteristics. Hitherto, many algorithmic spindle detectors inherently make signal stationarity assumptions (e.g. Fourier transform-based approaches which are inappropriate for EEG signals, and frequently rely on additional information which may not be readily available in many practical settings (e.g. more than one EEG channels, or prior hypnogram assessment. This study proposes a novel signal processing methodology relying solely on a single EEG channel, and provides objective, accurate means towards probabilistically assessing the presence of sleep spindles in EEG signals. We use the intuitively appealing continuous wavelet transform (CWT with a Morlet basis function, identifying regions of interest where the power of the CWT coefficients corresponding to the frequencies of spindles (11-16 Hz is large. The potential for assessing the signal segment as a spindle is refined using local weighted smoothing techniques. We evaluate our findings on two databases: the MASS database comprising 19 healthy controls and the DREAMS sleep spindle database comprising eight participants diagnosed with various sleep pathologies. We demonstrate that we can replicate the experts’ sleep spindles assessment accurately in both databases (MASS database: sensitivity: 84%, specificity: 90%, false discovery rate 83%, DREAMS database: sensitivity: 76%, specificity: 92%, false discovery rate: 67%, outperforming six competing automatic sleep spindle detection algorithms in terms of correctly replicating the experts’ assessment of detected spindles.

  3. On the Possibility of Accelerating Positron on an Electron Wake at SABER

    International Nuclear Information System (INIS)

    Ischebeck, R.; Joshi, C.; Katsouleas, T.C.; Muggli, P.; Wang, X.

    2008-01-01

    A new approach for positron acceleration in non-linear plasma wakefields driven by electron beams is presented. Positrons can be produced by colliding an electron beam with a thin foil target embedded in the plasma. Integration of positron production and acceleration in one stage is realized by a single relativistic, intense electron beam. Simulations with the parameters of the proposed SABER facility [1] at SLAC suggest that this concept could be tested there

  4. Cells deficient in PARP-1 show an accelerated accumulation of DNA single strand breaks, but not AP sites, over the PARP-1-proficient cells exposed to MMS.

    Science.gov (United States)

    Pachkowski, Brian F; Tano, Keizo; Afonin, Valeriy; Elder, Rhoderick H; Takeda, Shunichi; Watanabe, Masami; Swenberg, James A; Nakamura, Jun

    2009-12-01

    Poly(ADP-ribose) polymerase-1 (PARP-1) is a base excision repair (BER) protein that binds to DNA single strand breaks (SSBs) and subsequently synthesizes and transfers poly(ADP-ribose) polymers to various nuclear proteins. Numerous biochemical studies have implicated PARP-1 as a modulator of BER; however, the role of PARP-1 in BER in living cells remains unclear partly due to lack of accurate quantitation of BER intermediates existing in cells. Since DT40 cells, chicken B lymphocytes, naturally lack PARP-2, DT40 cells allow for the investigation of the PARP-1 null phenotype without confounding by PARP-2. To test the hypothesis that PARP-1 is necessary for efficient BER during methylmethane sulfonate (MMS) exposure in vertebrate cells, intact DT40 cells and their isogenic PARP-1 null counterparts were challenged with different exposure scenarios for phenotypic characterization. With chronic exposure, PARP-1 null cells exhibited sensitivity to MMS but with an acute exposure did not accumulate base lesions or AP sites to a greater extent than wild-type cells. However, an increase in SSB content in PARP-1 null cell DNA, as indicated by glyoxal gel electrophoresis under neutral conditions, suggested the presence of BER intermediates. These data suggest that during exposure, PARP-1 impacts the stage of BER after excision of the deoxyribosephosphate moiety from the 5' end of DNA strand breaks by polymerase beta.

  5. Experimental demonstration of dielectric structure based two beam acceleration

    International Nuclear Information System (INIS)

    Gai, W.; Conde, M. E.; Konecny, R.; Power, J. G.; Schoessow, P.; Sun, X.; Zou, P.

    2000-01-01

    We report on the experimental results of the dielectric based two beam accelerator (step-up transformer). By using a single high charge beam, we have generated and extracted a high power RF pulse from a 7.8 GHz primary dielectric structure and then subsequently transferred to a second accelerating structure with higher dielectric constant and smaller transverse dimensions. We have measured the energy change of a second (witness) beam passing through the acceleration stage. The measured gradient is >4 times the deceleration gradient. The detailed experiment of set-up and results of the measurements are dimmed. Future plans for the development of a 100 MeV demonstration accelerator based on this technique is presented

  6. Effect of gravitational acceleration, hypokinesia and hypodynamia on the structure of the intestinal vascular bed

    Science.gov (United States)

    Nikitin, M. V.

    1980-01-01

    A series of experiments comparing single and combined effects of hypokinesia and gravitational acceleration on morphology of intestinal blood vessels are discussed. Results indicate that hypokinesia has a whole body nonspecific effect reflected even in an organ whose activity shows little or no change due to hypokinesia. In early hypokinetic stages blood redistribution caused anorexia, intestinal atonia, and secretory disruption. Destructive changes from further exposure include aneurisms, varicoses, extravascular movement of blood elements, and vascular wall muscle fiber degeneration. The effect of acceleration is greatest in the ventrodorsal direction. Changes due to acceleration then hypokinesia are like those due to hypokinesia alone; changes due to acceleration before and after hypokinesia are like those due to acceleration. Adaptation raises acceleration tolerance but the effects do not survive four-week hypokinesia.

  7. Multiple stage railgun

    International Nuclear Information System (INIS)

    Aaland, K.; Hawke, R.S.; Scudder, J.K.

    1982-01-01

    A multiple stage magnetic railgun accelerator for accelerating a projectile by movement of a plasma arc along the rails. The railgun is divided into a plurality of successive rail stages which are sequentially energized by separate energy sources as the projectile moves through the bore of the railgun. Propagation of energy from an energized rail stage back towards the breech end of the railgun can be prevented by connection of the energy sources to the rails through isolation diodes. Propagation of energy from an energized rail stage back towards the breech end of the railgun can also be prevented by dividing the rails into electrically isolated rail sections. In such case means are used to extinguish the arc at the end of each energized stage and a fuse or laser device is used to initiate a new plasma arc in the next energized rail stage

  8. A Proposal Of Simulation Model Of A Wind-Steering System For Sailing Yachts, Based On Single-Stage Servo-Pendulum Coupled With Main Rudder

    Directory of Open Access Journals (Sweden)

    Piętak Andrzej

    2015-04-01

    Full Text Available The aim of this study was to investigate possible application of fast design prototyping methods for wind-steering systems used in offshore sailing yachts. The development of such methods would help to speed up the construction work and reduce the scope of necessary experimental research, prior to implementation of the system. In the present work, based on an analysis of existing designs of windvane systems, a preliminary selection of the system configuration has been undertaken, in terms of a compromise between efficiency, performance, and design complexity. Construction design of a single-stage, servo – pendulum system, has been developed by using the Autodesk Inventor design package. Next, based on the design data, a simulation model of the system, has been produced by using Matlab - Simulink software and SimMechanics library. The model was further verified in terms of kinematics mapping with the use of Matlab visualization tools.

  9. Performance comparison of single-stage mixed-refrigerant Joule–Thomson cycle and reverse Brayton cycle for cooling 80 to 120 K temperature-distributed heat loads

    Science.gov (United States)

    Wang, H. C.; Chen, G. F.; Gong, M. Q.; Li, X.

    2017-12-01

    Thermodynamic performance comparison of single-stage mixed-refrigerant Joule–Thomson cycle (MJTR) and pure refrigerant reverse Brayton cycle (RBC) for cooling 80 to 120 K temperature-distributed heat loads was conducted in this paper. Nitrogen under various liquefaction pressures was employed as the heat load. The research was conducted under nonideal conditions by exergy analysis methods. Exergy efficiency and volumetric cooling capacity are two main evaluation parameters. Exergy loss distribution in each process of refrigeration cycle was also investigated. The exergy efficiency and volumetric cooling capacity of MJTR were obviously superior to RBC in 90 to 120 K temperature zone, but still inferior to RBC at 80 K. The performance degradation of MJTR was caused by two main reasons: The high fraction of neon resulted in large entropy generation and exergy loss in throttling process. Larger duty and WLMTD lead to larger exergy losses in recuperator.

  10. Correlation of precursor and product ions in single-stage high resolution mass spectrometry. A tool for detecting diagnostic ions and improving the precursor elemental composition elucidation

    Energy Technology Data Exchange (ETDEWEB)

    Borràs, S. [Departament de Química Analítica, Universitat de Barcelona, Martí i Franquès 1-11, 08028 Barcelona (Spain); Kaufmann, A., E-mail: anton.kaufmann@klzh.ch [Official Food Control Authority, Fehrenstrasse 15, 8032 Zürich (Switzerland); Companyó, R. [Departament de Química Analítica, Universitat de Barcelona, Martí i Franquès 1-11, 08028 Barcelona (Spain)

    2013-04-15

    Highlights: ► We are describing a technique to spot ions which are derived from each other. ► Single stage high resolution data is used. ► This “in silicon” technique is compared to conventional precursor scan. ► Some applications for this technique are presented. -- Abstract: Monitoring of common diagnostic fragments is essential for recognizing molecules which are members of a particular compound class. Up to now, unit resolving tandem quadrupole mass spectrometers, operating in the precursor ion scan mode, have been typically used to perform such analysis. By means of high-resolution mass spectrometry (HRMS) a much more sensitive and selective detection can be achieved. However, using a single-stage HRMS instrument, there is no unequivocal link to the corresponding precursor ion, since such instrumentation does not permit a previous precursor selection. Thus, to address this limitation, an in silico approach to locate precursor ions, based on diagnostic fragments, was developed. Implemented as an Excel macro, the algorithm rapidly assembles and surveys exact mass data to provide a list of feasible precursor candidates according to the correlation of the chromatographic peak shape profile and other additional filtering criteria (e.g. neutral losses and isotopes). The macro was tested with two families of veterinary drugs, sulfonamides and penicillins, which are known to yield diagnostic product ions when fragmented. Data sets obtained from different food matrices (fish and liver), both at high and low concentration of the target compounds, were investigated in order to evaluate the capabilities and limitations of the reported approach. Finally, other possible applications of this technique, such as the elucidation of elemental compositions based on product ions and corresponding neutral losses, were also presented and discussed.

  11. Evaluation of advanced hydraulic turbomachinery for underground pumped hydroelectric storage. Part 1. Single-stage regulated pump turbines for operating heads of 500 to 1000 m

    Energy Technology Data Exchange (ETDEWEB)

    Frigo, A.A.; Blomquist, C.A.; Degnan, J.R.

    1979-10-01

    High-head, large-capacity turbomachinery is needed for the concept of underground pumped hydroelectric storage to be technically and economically attractive. Single-stage, reversible, Francis-type pump turbines with adjustable wicket gates appear to offer the most economically attractive option for heads between about 500 and 1000 m. The feasibility of developing these types of machines for capacities up to 500 MW and operating heads up to 1000 m has been evaluated. Preliminary designs have been generated for six single-stage pump turbines. The designs are for capacities of 350 and 500 MW and for operating heads of 500, 750, and 1000 m. The report contains drawings of the machines along with material specifications and hydraulic performance data. Mechanical, hydraulic, and economic analyses indicate that these machines will behave according to the criteria used to design them and that they can be built at a reasonable cost. The stress and deflection responses of the 500-MW, 100-m-head pump turbine, determined by detailed finite element analysis techniques, give solid evidence of the integrity of the conceptual designs of the six units and indicate no unsolvable problems. Results of a life expectancy analysis of the wicket gates indicate that a near infinite life can be expected for these components when they are subjected to normal design loads. Efficiencies of 90.7 and 91.4% in the generating and pumping modes, respectively, can be expected for the 500-MW, 1000-m-head unit. Performances of the other five machines are comparable. The specific costs of the pump turbines in mid-1978 US dollars per kW vary from 19.2 to 11.8 over a head range of from 500 to 1000 m for the 500-MW machines and from 20.0 to 12.3 for the 350-MW machines.

  12. In-source collision-induced dissociation (IS-CID): Applications, issues and structure elucidation with single-stage mass analyzers.

    Science.gov (United States)

    Parcher, Jon F; Wang, Mei; Chittiboyina, Amar G; Khan, Ikhlas A

    2018-01-01

    A discussion of the definition, advantages, and issues with the formation of ions in the transition region between an electrospray ionization (ESI) source and the ion optics of a mass analyzer is presented. The various types of ions formed in the so-called in-source collision-induced dissociation (IS-CID) process are illustrated. Applications of IS-CID with single-stage mass analyzers, such as structure elucidation and quantitation, are demonstrated. The discussion is illustrated by examples of the in-source fragmentation of ginkgolides, which are marker compounds found only in Ginkgo biloba. Supercritical fluid chromatography (SFC) with non-aqueous eluents was used to achieve a fast resolution of the ginkgolides without the hydrolysis reactions possible with aqueous high-performance liquid chromatography (HPLC) eluents. In-source ion generation occurs at relatively high pressures (ca. 1-3 torr) compared to the low pressure normally observed in collision chambers of tandem mass spectrometry (MS/MS). As a result, the fragmentation process is complex and often generates ions other than the fragments observed with classic CID or the same ions at different intensities. The objective of the current tutorial is to illustrate the conditions under which single-stage, quadrupole or time-of-flight mass analyzers with electrospray or in-air (direct analysis in real time; DART) ionization can be used for quantitation and structure elucidation in a manner similar to that observed with MS/MS. While the low m/z (≤ [M±H] ± ) ions formed in-source often duplicate the ions observed in MS/MS systems, it is the focus of this discussion to illustrate the utility of in-source generated fragment ions that may not be observed or observed at different intensities than in the collision cells of MS/MS instruments. Copyright © 2017 John Wiley & Sons, Ltd.

  13. Efficacy of single-stage breast-conserving treatment using multicatheter partial breast brachytherapy evaluated by GEC-ESTRO phase 3 trial.

    Science.gov (United States)

    Sato, Kazuhiko; Fuchikami, Hiromi; Kato, Masahiro; Shimo, Takahiro; Kubota, Jun; Takeda, Naoko; Inoue, Yuko; Seto, Hiroshi; Okawa, Tomohiko

    2017-10-01

    The GEC-ESTRO has reported the equivalent outcomes of partial breast irradiation (PBI) using multicatheter interstitial brachytherapy (MCB) to whole breast irradiation (WBI) in breast-conserving therapy (BCT). We performed single-stage BCT with partial breast brachytherapy by intraoperative catheter placement. After the categorization of patients into inclusion and exclusion criteria on this trial, our databases were evaluated in order to translate it to Japanese patients. Patients undergoing BCT were retrospectively examined between November 2007 and December 2015. The technique is an open-cavity implant with a dose of 32 Gy in 8 fractions. The 4-year clinical outcomes of MCB-PBI were evaluated in the 2 distinct categories, and the comparison of the outcomes of MCB-PBI with WBI was performed in patients with unfavorable features. Of a total of 501 lesions undergoing BCT, 301 lesions were treated with MCB-PBI and 200 lesions with WBI. At the median follow-up time of 52 months, the 4-year rate of ipsilateral breast tumor recurrence (IBTR)-free, disease-free (DFS), and overall survival (OS) in patients with MCB-PBI and WBI were 98.9% vs. 98.0% ( p = 0.56), 97.0% vs. 95.3% ( p = 0.78), and 99.6% vs. 98.2% ( p = 0.38), respectively. Although in exclusion cohort treated with MCB-PBI, IBTR-free, and disease-free survival were significantly worse than in inclusion cohort, non-significantly worse outcomes was demonstrated than in exclusion cohort with WBI; IBTR-free survival (95.0% vs. 97.2%, p = 0.24), and disease-free survival (95.0% vs. 95.8%, p = 0.31). Single-stage BCT using MCB-PBI offered similar tumor control rates compering to WBI. However, further research is needed to define the benefit for patients with an exclusion criteria.

  14. A novel, fast and efficient single-sensor automatic sleep-stage classification based on complementary cross-frequency coupling estimates.

    Science.gov (United States)

    Dimitriadis, Stavros I; Salis, Christos; Linden, David

    2018-04-01

    Limitations of the manual scoring of polysomnograms, which include data from electroencephalogram (EEG), electro-oculogram (EOG), electrocardiogram (ECG) and electromyogram (EMG) channels have long been recognized. Manual staging is resource intensive and time consuming, and thus considerable effort must be spent to ensure inter-rater reliability. As a result, there is a great interest in techniques based on signal processing and machine learning for a completely Automatic Sleep Stage Classification (ASSC). In this paper, we present a single-EEG-sensor ASSC technique based on the dynamic reconfiguration of different aspects of cross-frequency coupling (CFC) estimated between predefined frequency pairs over 5 s epoch lengths. The proposed analytic scheme is demonstrated using the PhysioNet Sleep European Data Format (EDF) Database with repeat recordings from 20 healthy young adults. We validate our methodology in a second sleep dataset. We achieved very high classification sensitivity, specificity and accuracy of 96.2 ± 2.2%, 94.2 ± 2.3%, and 94.4 ± 2.2% across 20 folds, respectively, and also a high mean F1 score (92%, range 90-94%) when a multi-class Naive Bayes classifier was applied. High classification performance has been achieved also in the second sleep dataset. Our method outperformed the accuracy of previous studies not only on different datasets but also on the same database. Single-sensor ASSC makes the entire methodology appropriate for longitudinal monitoring using wearable EEG in real-world and laboratory-oriented environments. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  15. A model of the two-stage Hall thruster discharge

    International Nuclear Information System (INIS)

    Ahedo, E.; Parra, F.I.

    2005-01-01

    The effect of a third, active electrode placed inside the ceramic chamber of a Hall thruster is analyzed. Both electron-collecting and electron-emitting modes are considered. Significant efficiency enhancement with respect to the single-stage operation can be obtained for a good electron-emitting electrode, placed in an intermediate location of the acceleration region, and for an anode-to-electrode (inner-stage) potential significantly larger than the ionization potential. Optimum values of the electrode location and voltage are determined. The performance improvement is due to a reduction of the energy losses to the chamber walls. This is the consequence of lower Joule heating and thus lower electron temperature in the outer stage. When the ionization process is efficient already in the single-stage operation (i) two-stage operation does not affect practically the propellant and voltage utilizations and (ii) thrust efficiency decreases when the intermediate electrode works as an electron collector

  16. STAT3 single nucleotide polymorphism rs4796793 SNP does not correlate with response to adjuvant IFNα therapy in stage III melanoma patients

    Directory of Open Access Journals (Sweden)

    David eSchrama

    2014-11-01

    Full Text Available Interferon alpha (IFNα is approved for adjuvant treatment of stage III melanoma in Europe and the US. Its clinical efficacy, however, is restricted to a subpopulation of patients while side effects occur in most of treated patients. Thus, the identification of predictive biomarkers would be highly beneficial to improve the benefit to risk ratio. In this regard, STAT3 is important for signaling of the IFNα receptor. Moreover, the STAT3 single nucleotide polymorphism (SNP rs4796793 has recently been reported to be associated with IFNα sensitivity in metastatic renal cell carcinoma. To translate this notion to melanoma, we scrutinized the impact of rs4796793 functionally and clinically in this cancer. Interestingly, melanoma cells carrying the minor allele of rs4796793 were the most sensitive to IFNα in vitro. However, we did not detect a correlation between SNP genotype and STAT3 mRNA expression for either melanoma cells or for peripheral blood lymphocytes. Next, we analyzed the impact of rs4796793 on the clinical outcome of 259 stage III melanoma patients of which one third had received adjuvant IFNα treatment. These analyses did not reveal a significant association between the STAT3 rs4796793 SNP and patients’ progression free or overall survival when IFN treated and untreated patients were compared. In conclusion, STAT3 rs4796793 SNP is no predictive marker for the efficacy of adjuvant IFNα treatment in melanoma patients.

  17. Single-cell analysis of differences in transcriptomic profiles of oocytes and cumulus cells at GV, MI, MII stages from PCOS patients.

    Science.gov (United States)

    Liu, Qiwei; Li, Yumei; Feng, Yun; Liu, Chaojie; Ma, Jieliang; Li, Yifei; Xiang, Huifen; Ji, Yazhong; Cao, Yunxia; Tong, Xiaowen; Xue, Zhigang

    2016-12-22

    Polycystic ovary syndrome (PCOS) is a common frequent endocrine disorder among women of reproductive age. Although assisted reproductive techniques (ARTs) are used to address subfertility in PCOS women, their effectiveness is not clear. Our aim was to compare transcriptomic profiles of oocytes and cumulus cells (CCs) between women with and without PCOS, and assess the effectiveness of ARTs in treating PCOS patients. We collected oocytes and CCs from 16 patients with and without PCOS patients to categorize them into 6 groups according to oocyte nuclear maturation. Transcriptional gene expression of oocyte and CCs was determined via single-cell RNA sequencing. The ratio of fertilization and cleavage was higher in PCOS patients than in non-PCOS patients undergoing ARTs, and there was no difference in the number of high-quality embryos between the groups. Differentially expressed genes including PPP2R1A, PDGFRA, EGFR, GJA1, PTGS2, TNFAIP6, TGF-β1, CAV1, INHBB et al. were investigated as potential causes of PCOS oocytes and CCs disorder at early stages, but their expression returned to the normal level at the metaphase II (MII) stage via ARTs. In conclusion, ARTs can improve the quality of cumulus-oocyte complex (COC) and increase the ratio of fertilization and cleavage in PCOS women.

  18. Accelerated Learning 1985-1986.

    Science.gov (United States)

    Cullen, Audrey; And Others

    A second language teaching technique using relaxation, imagination, and music to accelerate the learning process is imagination, and music to accelerate the learning process is discussed. Part 1 describes the classroom setting and the stages and processes of the technique. Part 2 outlines the theory and sources of the method in the literature of…

  19. High flux coherent super-continuum soft X-ray source driven by a single-stage, 10mJ, Ti:sapphire amplifier-pumped OPA.

    Science.gov (United States)

    Ding, Chengyuan; Xiong, Wei; Fan, Tingting; Hickstein, Daniel D; Popmintchev, Tenio; Zhang, Xiaoshi; Walls, Mike; Murnane, Margaret M; Kapteyn, Henry C

    2014-03-10

    We demonstrate the highest flux tabletop source of coherent soft X-rays to date, driven by a single-stage 10 mJ Ti:sapphire regenerative amplifier at 1 kHz. We first down-convert the laser to 1.3 µm using a parametric amplifier, before up-converting it to soft X-rays using high harmonic generation in a high-pressure, phase matched, hollow waveguide geometry. The resulting optimally phase matched broadband spectrum extends to 200 eV, with a soft X-ray photon flux of > 10(6) photons/pulse/1% bandwidth at 1 kHz, corresponding to > 10(9) photons/s/1% bandwidth, or approximately a three order-of-magnitude increase compared with past work. Finally, using this broad bandwidth X-ray source, we demonstrate X-ray absorption spectroscopy of multiple elements and transitions in molecules in a single spectrum, with a spectral resolution of 0.25 eV, and with the ability to resolve the near edge fine structure.

  20. Performance analysis of single stage libr-water absorption machine operated by waste thermal energy of internal combustion engine: Case study

    Science.gov (United States)

    Sharif, Hafiz Zafar; Leman, A. M.; Muthuraman, S.; Salleh, Mohd Najib Mohd; Zakaria, Supaat

    2017-09-01

    Combined heating, cooling, and power is also known as Tri-generation. Tri-generation system can provide power, hot water, space heating and air -conditioning from single source of energy. The objective of this study is to propose a method to evaluate the characteristic and performance of a single stage lithium bromide-water (LiBr-H2O) absorption machine operated with waste thermal energy of internal combustion engine which is integral part of trigeneration system. Correlations for computer sensitivity analysis are developed in data fit software for (P-T-X), (H-T-X), saturated liquid (water), saturated vapor, saturation pressure and crystallization temperature curve of LiBr-H2O Solution. Number of equations were developed with data fit software and exported into excel work sheet for the evaluation of number of parameter concerned with the performance of vapor absorption machine such as co-efficient of performance, concentration of solution, mass flow rate, size of heat exchangers of the unit in relation to the generator, condenser, absorber and evaporator temperatures. Size of vapor absorption machine within its crystallization limits for cooling and heating by waste energy recovered from exhaust gas, and jacket water of internal combustion engine also presented in this study to save the time and cost for the facilities managers who are interested to utilize the waste thermal energy of their buildings or premises for heating and air conditioning applications.

  1. DART-bid: dose-differentiated accelerated radiation therapy, 1.8 Gy twice daily. High local control in early stage (I/II) non-small-cell lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Zehentmayr, Franz; Wurstbauer, Karl; Deutschmann, Heinz; Sedlmayer, Felix [Landeskrankenhaus Salzburg, Univ.-Klinik fuer Radiotherapie und Radio-Onkologie, Univ.-Klinikum der Paracelsus Medizinischen Privatuniversitaet, Salzburg (Austria); Paracelsus Medizinische Privatuniversitaet, Institute for Research and Development of Advanced Radiation Technologies (radART), Salzburg (Austria); Fussl, Christoph; Kopp, Peter; Dagn, Karin; Fastner, Gerd [Landeskrankenhaus Salzburg, Univ.-Klinik fuer Radiotherapie und Radio-Onkologie, Univ.-Klinikum der Paracelsus Medizinischen Privatuniversitaet, Salzburg (Austria); Porsch, Peter; Studnicka, Michael [Landeskrankenhaus Salzburg, Univ.-Klinik fuer Pneumologie, Univ.-Klinikum der Paracelsus Medizinischen Privatuniversitaet, Salzburg (Austria)

    2014-09-23

    While surgery is considered standard of care for early stage (I/II), non-small-cell lung cancer (NSCLC), radiotherapy is a widely accepted alternative for medically unfit patients or those who refuse surgery. International guidelines recommend several treatment options, comprising stereotactic body radiation therapy (SBRT) for small tumors, conventional radiotherapy ≥ 60 Gy for larger sized especially centrally located lesions or continuous hyperfractionated accelerated RT (CHART). This study presents clinical outcome and toxicity for patients treated with a dose-differentiated accelerated schedule using 1.8 Gy bid (DART-bid). Between April 2002 and December 2010, 54 patients (median age 71 years, median Karnofsky performance score 70 %) were treated for early stage NSCLC. Total doses were applied according to tumor diameter: 73.8 Gy for < 2.5 cm, 79.2 Gy for 2.5-4.5 cm, 84.6 Gy for 4.5-6 cm, 90 Gy for > 6 cm. The median follow-up was 28.5 months (range 2-108 months); actuarial local control (LC) at 2 and 3 years was 88 %, while regional control was 100 %. There were 10 patients (19 %) who died of the tumor, and 18 patients (33 %) died due to cardiovascular or pulmonary causes. A total of 11 patients (20 %) died intercurrently without evidence of progression or treatment-related toxicity at the last follow-up, while 15 patients (28 %) are alive. Acute esophagitis ≤ grade 2 occurred in 7 cases, 2 patients developed grade 2 chronic pulmonary fibrosis. DART-bid yields high LC without significant toxicity. For centrally located and/or large (> 5 cm) early stage tumors, where SBRT is not feasible, this method might serve as radiotherapeutic alternative to present treatment recommendations, with the need of confirmation in larger cohorts. (orig.) [German] Die Standardbehandlung fuer nichtkleinzellige Bronchialkarzinome (NSCLC) im Stadium I/II ist die Operation, wobei Radiotherapie fuer Patienten, die nicht operabel sind oder die Operation ablehnen, als Alternative

  2. Laser accelerator

    OpenAIRE

    Vigil, Ricardo

    2014-01-01

    Approved for public release; distribution is unlimited In 1979,W. B. Colson and S. K. Ride proposed a new kind of electron accelerator using a uniform magnetic field in combination with a circularly-polarized laser field. A key concept is to couple the oscillating electric field to the electron’s motion so that acceleration is sustained. This dissertation investigates the performance of the proposed laser accelerator using modern high powered lasers and mag-netic fields that are significan...

  3. Electrostatic accelerators

    CERN Document Server

    Hinterberger, F

    2006-01-01

    The principle of electrostatic accelerators is presented. We consider Cockcroft– Walton, Van de Graaff and Tandem Van de Graaff accelerators. We resume high voltage generators such as cascade generators, Van de Graaff band generators, Pelletron generators, Laddertron generators and Dynamitron generators. The speci c features of accelerating tubes, ion optics and methods of voltage stabilization are described. We discuss the characteristic beam properties and the variety of possible beams. We sketch possible applications and the progress in the development of electrostatic accelerators.

  4. Accelerator development

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    Because the use of accelerated heavy ions would provide many opportunities for new and important studies in nuclear physics and nuclear chemistry, as well as other disciplines, both the Chemistry and Physics Divisions are supporting the development of a heavy-ion accelerator. The design of greatest current interest includes a tandem accelerator with a terminal voltage of approximately 25 MV injecting into a linear accelerator with rf superconducting resonators. This combined accelerator facility would be capable of accelerating ions of masses ranging over the entire periodic table to an energy corresponding to approximately 10 MeV/nucleon. This approach, as compared to other concepts, has the advantages of lower construction costs, lower operating power, 100 percent duty factor, and high beam quality (good energy resolution, good timing resolution, small beam size, and small beam divergence). The included sections describe the concept of the proposed heavy-ion accelerator, and the development program aiming at: (1) investigation of the individual questions concerning the superconducting accelerating resonators; (2) construction and testing of prototype accelerator systems; and (3) search for economical solutions to engineering problems. (U.S.)

  5. Laser cellulite treatment and laser-assisted lipoplasty of the thighs and buttocks: Combined modalities for single stage contouring of the lower body.

    Science.gov (United States)

    Petti, Christine; Stoneburner, Jacqueline; McLaughlin, Laura

    2016-01-01

    Cellulite and lipodystrophy are often found together, especially in areas of the buttocks and thighs, causing skin surface irregularities. Each of these conditions is currently treated independently as two separate surgical procedures. In our practice, we developed a novel combined approach for the simultaneous treatment of cellulite and lipodystrophy, as a single stage procedure in the same anatomic area. For the treatment of cellulite, we used the Nd:YAG laser at a wavelength of 1,440-nm, along with an innovative 1,000-micron directional side-firing fiber optic laser system. For the treatment of lipodystrophy, the Nd:YAG laser with a 1,440 nm wavelength, along with a fiber optic laser system was used. The objective of this study is to determine the efficacy and safety of a combined approach for the simultaneous treatment of cellulite and lipodystrophy. In 2012, 16 subjects with noticeable cellulite, Grade II and Grade III, accompanied by mild-to-moderate lipodystrophy of the lower body received single treatments of the Nd:YAG laser at a wavelength of 1,440-nm along with the 1,000-micron side-firing fiber optic laser system for simultaneous treatments of both cellulite and lipodystrophy. Patients were assessed at baseline and 3-6 months post-treatment by a modified Nurnberger-Muller scale utilized to quantify the cellulite severity. Additionally, patient satisfaction and a global aesthetic improvement scale were used to measure the improvement in lipodystrophy. Blinded reviewers identified the correct baseline photographs 97% of the time when presented with a set of photographs. The median modified Nurnberger-Muller scale score at baseline was 4.75 ± 1.2 and the average improvement was 2.0 ± 1.2. Global aesthetic improvement scores ranged from 1 to 3 with an average of 1.58 indicating a much-improved overall appearance. Satisfaction was high for both physicians and patients with scores corresponding to extremely satisfied/satisfied. Precise, effective

  6. LIBO accelerates

    CERN Multimedia

    2002-01-01

    The prototype module of LIBO, a linear accelerator project designed for cancer therapy, has passed its first proton-beam acceleration test. In parallel a new version - LIBO-30 - is being developed, which promises to open up even more interesting avenues.

  7. Induction accelerators

    CERN Document Server

    Takayama, Ken

    2011-01-01

    A broad class of accelerators rests on the induction principle whereby the accelerating electrical fields are generated by time-varying magnetic fluxes. Particularly suitable for the transport of bright and high-intensity beams of electrons, protons or heavy ions in any geometry (linear or circular) the research and development of induction accelerators is a thriving subfield of accelerator physics. This text is the first comprehensive account of both the fundamentals and the state of the art about the modern conceptual design and implementation of such devices. Accordingly, the first part of the book is devoted to the essential features of and key technologies used for induction accelerators at a level suitable for postgraduate students and newcomers to the field. Subsequent chapters deal with more specialized and advanced topics.

  8. Accelerating Inspire

    CERN Document Server

    AUTHOR|(CDS)2266999

    2017-01-01

    CERN has been involved in the dissemination of scientific results since its early days and has continuously updated the distribution channels. Currently, Inspire hosts catalogues of articles, authors, institutions, conferences, jobs, experiments, journals and more. Successful orientation among this amount of data requires comprehensive linking between the content. Inspire has lacked a system for linking experiments and articles together based on which accelerator they were conducted at. The purpose of this project has been to create such a system. Records for 156 accelerators were created and all 2913 experiments on Inspire were given corresponding MARC tags. Records of 18404 accelerator physics related bibliographic entries were also tagged with corresponding accelerator tags. Finally, as a part of the endeavour to broaden CERN's presence on Wikipedia, existing Wikipedia articles of accelerators were updated with short descriptions and links to Inspire. In total, 86 Wikipedia articles were updated. This repo...

  9. A prospective phase I comparison of toxicity and cosmesis outcomes of single-fraction IORT and hypofractionated radiotherapy with IORT boost in early-stage breast cancer.

    Science.gov (United States)

    Bhandari, Tanuja; Babaran, Wesley; Forouzannia, Afshin; Williams, Venita; Harness, Jay; Carpenter, Michele; Gobran, Maher; Khanijou, Rajesh; Wagman, Brittany; Ash, Robert; Wagman, Lawrence D

    Radiation therapy is proven to reduce local recurrence in patients with early-stage breast cancer. To reduce toxicity, treatment time, and improve accuracy, intraoperative radiation therapy was used as definitive treatment or as a boost. The study's objective was to compare the short-term toxicity and cosmesis of single-fraction (SF) IORT and hypofractionated radiotherapy with IORT boost (HfB) given as definitive treatment. Between March 2011 and December 2013, 57 patients aged 45-91 years and 24 patients aged 43-83 years (total n = 81) with Stage 0-II were treated with SF or HfB (Mobetron, IntraOp Medical, Sunnyvale, CA). For SF treatment, 21 Gy was delivered using 4.5-6 cm applicators with electron energies from 6 to 12 MeV. For HfB, an intraoperative boost of 10 Gy was delivered using 4-7 cm applicators with energies from 4 to 12 MeV followed by whole-breast radiation with 40.5 Gy over 15 fractions. Toxicity was assessed at 2 weeks, 6 months, and 12 months per Radiation Therapy Oncology Group acute skin toxicity criteria and cosmesis. At 12 months, SF and HfB were well tolerated by all patients with no Grade 3+ toxicity. At 1 year, Grade-2 toxicity was resolved. Ninety-eight percent of SF patients and ninety percent of HfB patients had 0-1 grade toxicity. In the SF and HfB groups, 100% of patients had excellent or good cosmesis at 12-month followup interval. The SF exhibited a more favorable cosmesis with a higher percentage of excellent scores compared with HfB (80.4% vs. 45%; p = 0.0033). After breast conservation surgery, SF or HfB may be an option for patients with early-stage breast cancer compared to conventional external beam radiotherapy. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  10. Control scheme towards enhancing power quality and operational efficiency of single-phase two-stage grid-connected photovoltaic systems

    Directory of Open Access Journals (Sweden)

    Mahmoud Salem

    2015-12-01

    Full Text Available Achieving high reliable grid-connected photovoltaic (PV systems with high power quality and high operation efficiency is highly required for distributed generation units. A double grid-frequency voltage ripple is found on the dc-link voltage in single-phase photovoltaic grid-connected systems due to the unbalance of the instantaneous dc input and ac output powers. This voltage ripple has undesirable effects on the power quality and operational efficiency of the whole system. Harmonic distortion in the injected current to the grid is one of the problems caused by this double grid-frequency voltage ripple. The double grid frequency ripple propagates to the PV voltage and current which disturb the extracted maximum power from the PV array. This paper introduces intelligent solutions towards mitigate the side effects of the double grid-frequency voltage ripple on the transferred power quality and the operational efficiency of single-phase two-stage grid-connected PV system. The proposed system has three control loops: MPPT control loop, dc-link voltage control loop and inverter current control loop. Solutions are introduced for all the three control loops in the system. The current controller cancels the dc-link voltage effect on the total harmonic distortion of the output current. The dc-link voltage controller is designed to generate a ripple free reference current signal that leads to enhance the quality of the output power. Also a modified MPPT controller is proposed to optimize the extracted power from the PV array. Simulation results show that higher injected power quality is achieved and higher efficiency of the overall system is realized.

  11. FMIT accelerator

    International Nuclear Information System (INIS)

    Armstrong, D.D.

    1983-01-01

    A 35-MeV 100-mA cw linear accelerator is being designed by Los Alamos for use in the Fusion Materials Irradiation Test (FMIT) Facility. Essential to this program is the design, construction, and evaluation of performance of the accelerator's injector, low-energy beam transport, and radio-frequency quadrupole sections before they are shipped to the facility site. The installation and testing of some of these sections have begun as well as the testing of the rf, noninterceptive beam diagnostics, computer control, dc power, and vacuum systems. An overview of the accelerator systems and the performance to date is given

  12. Immediate, single stage, truly anatomic zirconia implant in lower molar replacement: a case report with 2.5 years follow-up.

    Science.gov (United States)

    Pirker, W; Wiedemann, D; Lidauer, A; Kocher, A A

    2011-02-01

    This report demonstrates the clinical use of a modified, truly anatomic, root-analogue zirconia implant for immediate replacement of a two-rooted, left first mandibular molar. A 50-year-old female patient with chronic apical periodontitis of the left mandibulary first molar was referred and the tooth was extracted. The mesial root had to be removed surgically due to a root fracture. A truly anatomical, root identical, roughened zirconia implant modified by macro-retentions was manufactured and placed into the extraction socket by tapping 7 days later. After 4 months a composite crown was cemented in place. No complications occurred during the healing period. A good functional and aesthetic result was achieved with minimal bone resorption and soft tissue recession at 30 months follow-up. This report describes the successful clinical use of an immediate, single stage, truly anatomical root-analogue zirconia implant for replacement of a two-rooted tooth. Significant modifications such as macro-retentions yielded primary stability and excellent osseointegration. This novel approach is minimally invasive, respects the underlying anatomy, aids socket prevention, is time- and cost-saving with good patient acceptance as there is no need for bone drilling, sinus lift, bone augmentation or other traumatic procedures. Copyright © 2010 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  13. Enhancement of the complete autotrophic nitrogen removal over nitrite process in a modified single-stage subsurface vertical flow constructed wetland: Effect of saturated zone depth.

    Science.gov (United States)

    Huang, Menglu; Wang, Zhen; Qi, Ran

    2017-06-01

    This study was conducted to explore enhancement of the complete autotrophic nitrogen removal over nitrite (CANON) process in a modified single-stage subsurface vertical flow constructed wetland (VSSF) with saturated zone, and nitrogen transformation pathways in the VSSF treating digested swine wastewater were investigated at four different saturated zone depths (SZDs). SZD significantly affected nitrogen transformation pathways in the VSSF throughout the experiment. As the SZD was 45cm, the CANON process was enhanced most effectively in the system owing to the notable enhancement of anammox. Correspondingly, the VSSF had the best TN removal performance [(76.74±7.30)%] and lower N 2 O emission flux [(3.50±0.22)mg·(m 2 ·h) - 1 ]. It could be concluded that autotrophic nitrogen removal via CANON process could become a primary route for nitrogen removal in the VSSF with optimized microenvironment that developed as a result of the appropriate SZD. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Multi-analysis determination of tropane alkaloids in cereals and solanaceaes seeds by liquid chromatography coupled to single stage Exactive-Orbitrap.

    Science.gov (United States)

    Marín-Sáez, Jesús; Romero-González, Roberto; Garrido Frenich, Antonia

    2017-10-06

    Tropane alkaloids are a wide group of substances that comprises more than 200 compounds occurring especially in the Solanaceae family. The main aim of this study is the development of a method for the analysis of the principal tropane alkaloids as atropine, scopolamine, anisodamine, tropane, tropine, littorine, homatropine, apoatropine, aposcopolamine, scopoline, tropinone, physoperuvine, pseudotropine and cuscohygrine in cereals and related matrices. For that, a simple solid-liquid extraction was optimized and a liquid chromatographic method coupled to a single stage Exactive-Orbitrap was developed. The method was validated obtaining recoveries in the range of 60-109% (except for some compounds in soy), precision values (expressed as relative standard deviation) lower than 20% and detection and quantification limits equal to or lower than 2 and 3μg/kg respectively. Finally, the method was applied to the analysis of different types of samples as buckwheat, linseed, soy and millet, obtaining positives for anisodamine, scopolamine, atropine, littorine and tropinone in a millet flour sample above the quantification limits, whereas atropine and scopolamine were detected in a buckwheat sample, below the quantification limit. Contaminated samples with Solanaceaes seeds (Datura Stramonium and Brugmansia Arborea) were also analysed, detecting concentrations up to 693μg/kg (scopolamine) for contaminated samples with Brugmansia seeds and 1847μg/kg (atropine) when samples were contaminated with Stramonium seeds. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. The effect of resorbable membranes on one-stage ridge augmentation in anterior single-tooth replacement: A randomized, controlled clinical trial.

    Science.gov (United States)

    Jonker, Brend P; Wolvius, Eppo B; van der Tas, Justin T; Pijpe, Justin

    2018-02-01

    To evaluate the effect of resorbable membranes on one-stage ridge augmentation procedures in small (2-4 mm) buccal bony dehiscences in anterior maxillary single-tooth replacement. Patients with a buccal bony dehiscence after implant placement in the esthetic zone were randomly allocated to one-stage ridge augmentation with (M+) or without a membrane (M-). Second-phase surgery was performed after 8 weeks, and follow-up was performed 1, 6, and ≥12 months after loading. Outcomes included implant survival and success, complications, clinical and radiographic parameters, esthetic results and patient satisfaction. Fifty-two patients were randomized to one-stage ridge augmentation with (n = 25) or without use of a membrane (n = 27). No significant differences in implant survival and success have been observed. The risk of having a small mucosal dehiscence was more than six times higher in the M+ group than in the M- group (RR 6.24, 95% CI 0.81 to 48.21). At the last follow-up, the bleeding index (BI) was marginally higher in the M+ group (14/9/2/0) compared to the M- group (24/2/0/0) (U = 205, Z = -2.97, p = .003, r = .42). The median change in marginal bone level was statistically lower in the M+ group (0.06 mm) than the M- group (0.60 mm) at last follow-up (U = 120, Z = -2.73 a p = .006 r = .42). Total pink esthetic index (PES) and white esthetic score (WES) and combined PES/WES were not significantly different between treatment groups at more than 12 months after loading. Only the subcategory root convexity/soft tissue color scored significantly lower in the M+ group (1.5) compared to the M- group (2.0) at the last follow-up (U = 172, Z = -2.34, p = .019 r = .34). No differences were found in patient satisfaction. The use of a resorbable membrane in small buccal bony dehiscences in anterior maxillary single-tooth replacement resulted in less marginal bone loss, but showed more mucosal dehiscences, higher bleeding scores and lower

  16. Horizontal Accelerator

    Data.gov (United States)

    Federal Laboratory Consortium — The Horizontal Accelerator (HA) Facility is a versatile research tool available for use on projects requiring simulation of the crash environment. The HA Facility is...

  17. Accelerator terminal voltage stability

    Science.gov (United States)

    Ferry, J. A.; Kolonko, J. J.; Phillips, S. H.; Lunstrum, S. J.

    1992-02-01

    Measurements reported at the 11th International Conference on Applications of Accelerators in Research and Industry [Schroeder et al., Nucl. Instr. and Meth. B56/B57 (1991) 1033] for a 1 MV single-ended Pelletron accelerator equipped with corona probe and tank liner voltage stabilizers have been extended by measuring the resonant yield of γ-rays from the 27Al(p, γ) 28Si reaction at 992 keV. Results show that terminal voltage stability is consistent with the earlier measurement of 31 V FWHM for ripple at 1 MV for periods of about one-half ( {1}/{2}) hour.

  18. Accelerator terminal voltage stability

    International Nuclear Information System (INIS)

    Ferry, J.A.; Kolonko, J.J.; Phillips, S.H.; Lunstrum, S.J.

    1992-01-01

    Measurements reported at the 11th International Conference on Applications of Accelerators in Research and Industry for a 1 MV single-ended Pelletron accelerator equipped with corona probe and tank liner voltage stabilizers have been extended by measuring the resonant yield of γ-rays from the 27 Al(p,γ) 28 Si reaction at 992 keV. Results show that terminal voltage stability is consistent with the earlier measurement of 31 V FWHM for ripple at 1 MV for periods of about one-half (1/2) hour. (orig.)

  19. Late Toxicity and Patient Self-Assessment of Breast Appearance/Satisfaction on RTOG 0319: A Phase 2 Trial of 3-Dimensional Conformal Radiation Therapy-Accelerated Partial Breast Irradiation Following Lumpectomy for Stages I and II Breast Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Chafe, Susan, E-mail: susan.chafe@albertahealthservices.ca [Department of Radiation Oncology, Cross Cancer Institute-University of Alberta, Edmonton, Alberta (Canada); Moughan, Jennifer [Department of Radiation Oncology, RTOG Statistical Center, Philadelphia, Pennsylvania (United States); McCormick, Beryl [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Wong, John [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland (United States); Pass, Helen [Womens' Breast Center, Stamford Hospital, Stamford, Connecticut (United States); Rabinovitch, Rachel [Department of Radiation Oncology, University of Colorado Denver, Aurora, Colorado (United States); Arthur, Douglas W. [Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia (United States); Petersen, Ivy [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota (United States); White, Julia [Department of Radiation Oncology, Ohio State University, Columbus, Ohio (United States); Vicini, Frank A. [Michigan Healthcare Professionals/21st Century Oncology, Farmington Hills, Michigan (United States)

    2013-08-01

    Purpose: Late toxicities and cosmetic analyses of patients treated with accelerated partial breast irradiation (APBI) on RTOG 0319 are presented. Methods and Materials: Patients with stages I to II breast cancer ≤3 cm, negative margins, and ≤3 positive nodes were eligible. Patients received three-dimensional conformal external beam radiation therapy (3D-CRT; 38.5 Gy in 10 fractions twice daily over 5 days). Toxicity and cosmesis were assessed by the patient (P), the radiation oncologist (RO), and the surgical oncologist (SO) at 3, 6, and 12 months from the completion of treatment and then annually. National Cancer Institute Common Terminology Criteria for Adverse Events, version 3.0, was used to grade toxicity. Results: Fifty-two patients were evaluable. Median follow-up was 5.3 years (range, 1.7-6.4 years). Eighty-two percent of patients rated their cosmesis as good/excellent at 1 year, with rates of 64% at 3 years. At 3 years, 31 patients were satisfied with the treatment, 5 were not satisfied but would choose 3D-CRT again, and none would choose standard radiation therapy. The worst adverse event (AE) per patient reported as definitely, probably, or possibly related to radiation therapy was 36.5% grade 1, 50% grade 2, and 5.8% grade 3 events. Grade 3 AEs were all skin or musculoskeletal-related. Treatment-related factors were evaluated to potentially establish an association with observed toxicity. Surgical bed volume, target volume, the number of beams used, and the use of bolus were not associated with late cosmesis. Conclusions: Most patients enrolled in RTOG 0319 were satisfied with their treatment, and all would choose to have the 3D-CRT APBI again.

  20. Interim Cosmetic Results and Toxicity Using 3D Conformal External Beam Radiotherapy to Deliver Accelerated Partial Breast Irradiation in Patients With Early-Stage Breast Cancer Treated With Breast-Conserving Therapy

    International Nuclear Information System (INIS)

    Vicini, Frank A.; Chen, Peter; Wallace, Michelle; Mitchell, Christina; Hasan, Yasmin; Grills, Inga; Kestin, Larry; Schell, Scott; Goldstein, Neal S.; Kunzman, Jonathan; Gilbert, Sam; Martinez, Alvaro

    2007-01-01

    Purpose: We present our ongoing clinical experience utilizing three-dimensional (3D)-conformal radiation therapy (3D-CRT) to deliver accelerated partial breast irradiation (APBI) in patients with early-stage breast cancer treated with breast-conserving therapy. Methods and Materials: Ninety-one consecutive patients were treated with APBI using our previously reported 3D-CRT technique. The clinical target volume consisted of the lumpectomy cavity plus a 10- to 15 -mm margin. The prescribed dose was 34 or 38.5 Gy in 10 fractions given over 5 consecutive days. The median follow-up was 24 months. Twelve patients have been followed for ≥4 years, 20 for ≥3.5 years, 29 for >3.0 years, 33 for ≥2.5 years, and 46 for ≥2.0 years. Results: No local recurrences developed. Cosmetic results were rated as good/excellent in 100% of evaluable patients at ≥ 6 months (n = 47), 93% at 1 year (n = 43), 91% at 2 years (n = 21), and in 90% at ≥3 years (n = 10). Erythema, hyperpigmentation, breast edema, breast pain, telangiectasias, fibrosis, and fat necrosis were evaluated at 6, 24, and 36 months after treatment. All factors stabilized by 3 years posttreatment with grade I or II rates of 0%, 0%, 0%, 0%, 9%, 18%, and 9%, respectively. Only 2 patients (3%) developed grade III toxicity (breast pain), which resolved with time. Conclusions: Delivery of APBI with 3D-CRT resulted in minimal chronic (≥6 months) toxicity to date with good/excellent cosmetic results. Additional follow-up is needed to assess the long-term efficacy of this form of APBI

  1. Field calculations, single-particle tracking, and beam dynamics with space charge in the electron lens for the Fermilab Integrable Optics Test Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Noll, Daniel [Goethe Univ., Frankfurt (Germany); Stancari, Giulio [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2015-11-17

    An electron lens is planned for the Fermilab Integrable Optics Test Accelerator as a nonlinear element for integrable dynamics, as an electron cooler, and as an electron trap to study space-charge compensation in rings. We present the main design principles and constraints for nonlinear integrable optics. A magnetic configuration of the solenoids and of the toroidal section is laid out. Singleparticle tracking is used to optimize the electron path. Electron beam dynamics at high intensity is calculated with a particle-in-cell code to estimate current limits, profile distortions, and the effects on the circulating beam. In the conclusions, we summarize the main findings and list directions for further work.

  2. Acceleration of polarized protons in the IHEP accelerator complex

    International Nuclear Information System (INIS)

    Anferov, V.A.; Ado, Yu.M.; Shoumkin, D.

    1995-01-01

    The paper considers possibility to accelerate polarized beam in the IHEP accelerator complex (including first stage of the UNK). The scheme of preserving beam polarization is described for all acceleration stages up to 400 GeV beam energy. Polarization and intensity of the polarized proton beam are estimated. The suggested scheme includes using two Siberian snakes in opposite straight sections of the UNK-1, where each snake consists of five dipole magnets. In the U-70 it is suggested to use one helical Siberian snake, which is turned on adiabatically at 10 GeV, and four pulsed quadrupoles. To incorporate the snake into the accelerator lattice it is proposed to make modification of one superperiod. This would make a 13 m long straight section. Spin depolarization in the Booster is avoided by decreasing the extraction energy to 0.9 GeV. Then no additional hardware is required in the Booster

  3. Minilaparoscopic radical hysterectomy (mLPS-RH) vs laparoendoscopic single-site radical hysterectomy (LESS-RH) in early stage cervical cancer: a multicenter retrospective study.

    Science.gov (United States)

    Fagotti, Anna; Ghezzi, Fabio; Boruta, David M; Scambia, Giovanni; Escobar, Pedro; Fader, Amanda N; Malzoni, Mario; Fanfani, Francesco

    2014-01-01

    To compare the perioperative outcomes of laparoendoscopic single-site radical hysterectomy (LESS-RH) and minilaparoscopic radical hysterectomy (mLPS-RH). Retrospective study (Canadian Task Force classification II-2). Seven institutions in Italy. Forty-six patents with early cervical cancer (FIGO stage IA2-IB1/IIA1) were included in the study. Nineteen patients (41.3%) underwent LESS-RH, and 27 (58.7%) underwent mLPS-RH. Pelvic lymph node dissection was performed in all patients. In the LESS-RH group, all surgical procedures were performed through a single umbilical multichannel port. In the mLPS-RH group, the procedure was completed using a 5-mm umbilical optical trocar and 3 additional 3-mm ancillary trocars, placed suprapubically and in the left and right lower abdominal regions. There was no difference in clinicopathologic characteristics at the time of diagnosis between the LESS-RH and mLPS-RH groups. Median operative time was 270 minutes (range, 149-380 minutes) for LESS-RH, and was 180 minutes (range, 90-240 minutes) for mLPS-RH (p = .001). No further differences were detected between the 2 groups insofar as type of radical hysterectomy, number of lymph nodes removed, or perioperative outcomes. In the LESS-RH group, conversion to laparotomy was necessary in 1 patient (5.3%) because of external iliac vein injury, and in another patient, conversion to standard laparoscopy was required because of truncal obesity. In the mLPS-RH group, no conversions were observed; however, a repeat operation was performed to repair a ureteral injury. The percentage of patients discharged 1 day after surgery was significantly higher in the LESS-RH group (57.9%) compared with the mLPS-RH group (25.0%) (p = .03). After a median follow-up of 27 months (range, 9-73 months), only 1 patient, who had undergone mLPS-RH, experienced pelvic recurrence and died of the disease. Both LESS-RH and mLPS-RH are feasible ultra-minimally invasive approaches for performance of radical hysterectomy

  4. Evaluation of a single-stage consumable-free modulator for comprehensive two-dimensional gas chromatography: analysis of polychlorinated biphenyls, organochlorine pesticides and chlorobenzenes.

    Science.gov (United States)

    Muscalu, Alina M; Edwards, Matthew; Górecki, Tadeusz; Reiner, Eric J

    2015-04-24

    Comprehensive two-dimensional gas chromatography (GC×GC) has been rapidly growing in popularity. The GC×GC separation is performed by interfacing a modulator between two columns of different selectivities. The modulator periodically traps and then re-injects the analytes eluting from the first column into the second column. The most popular GC×GC systems require consumables such as liquid N2 for the trapping function of the modulator. Although these systems are very effective, their costs are a hindrance to more widespread use. A new, single-stage thermal modulator for GC×GC that requires no consumables has been developed and tested. The device traps analytes using a proprietary stainless steel capillary trap compressed between two ceramic cooling pads. Analytes are thermally desorbed from the trap into the second column via resistive heating. To evaluate this system, a routine accredited method for the analysis of polychlorinated biphenyls, organochlorine pesticides and chlorobenzenes was run using the new modulator and its performance was compared to that of an industry standard modulation system. Within-day repeatability (% RSD ranging from 2% to 13%), between-day reproducibility (% RSD from 3% to 15%), as well as between-trap reproducibility were assessed. The results are very encouraging as negligible shifts in retention times (% RSD from 0.3% to 0.6% in the 1st dimension and 0.8% to 2% in the 2nd dimension) were observed for both within-day and day-to-day comparisons of the studied samples (ANOVA, p=0.9893 for the sediment reference material compared), and the quantitative results were comparable. Routine analysis and quality control applications will benefit from the improved reproducibility as the variances in cold/hot jet flows and temperatures are eliminated. An overview of the device operation and the results from this study are summarized. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Feasibility of Urgent-Start Peritoneal Dialysis in Older Patients with End-Stage Renal Disease: A Single-Center Experience.

    Science.gov (United States)

    Jin, Haijiao; Ni, Zhaohui; Mou, Shan; Lu, Renhua; Fang, Wei; Huang, Jiaying; Hu, Chunhua; Zhang, Haifen; Yan, Hao; Li, Zhenyuan; Yu, Zanzhe

    2018-01-01

    Patients with end-stage renal disease (ESRD) frequently require urgent-start dialysis. Recent evidence suggests that peritoneal dialysis (PD) might be a feasible alternative to hemodialysis (HD) in these patients, including in older patients. This retrospective study enrolled patients aged > 65 years with ESRD who underwent urgent dialysis without functional vascular access or PD catheter at a single center, from January 2011 to December 2014. Patients were grouped based on their dialysis modality (PD or HD). Patients unable to tolerate PD catheter insertion or wait for PD were excluded. Each patient was followed for at least 30 days after catheter insertion. Short-term (30-day) dialysis-related complications and patient survival were compared between the 2 groups. A total of 94 patients were enrolled, including 53 (56.4%) who underwent PD. The incidence of dialysis-related complications during the first 30 days was significantly lower in PD compared with HD patients (3 [5.7%] vs 10 [24.4%], p = 0.009). Logistic regression identified urgent-start HD as an independent risk factor for dialysis-related complications compared with urgent-start PD (odds ratio 4.760 [1.183 - 19.147], p = 0.028). The 6-, 12-, 24-, and 36-month survival rates in the PD and HD groups were 92.3% vs 94.6%, 82.4% vs 81.3%, 75.7% vs 74.2%, and 69.5% vs 60.6%, respectively, with no significant differences between the groups (log-rank = 0.011, p = 0.915). Urgent-start PD was associated with fewer short-term dialysis-related complications and similar survival to urgent-start HD in older patients with ESRD. Peritoneal dialysis may thus be a safe and effective dialysis modality for older ESRD patients requiring urgent dialysis. Copyright © 2018 International Society for Peritoneal Dialysis.

  6. Influence of Different Tibial Fixation Techniques on Initial Stability in Single-Stage Anterior Cruciate Ligament Revision With Confluent Tibial Tunnels: A Biomechanical Laboratory Study.

    Science.gov (United States)

    Schliemann, Benedikt; Treder, Maximilian; Schulze, Martin; Müller, Viktoria; Vasta, Sebastiano; Zampogna, Biaggio; Herbort, Mirco; Kösters, Clemens; Raschke, Michael J; Lenschow, Simon

    2016-01-01

    To kinematically and biomechanically compare 4 different types of tibial tunnel management in single-stage anterior cruciate ligament (ACL) revision reconstruction with the control: primary ACL reconstruction using a robotic-based knee testing setup. Porcine knees and flexor tendons were used. One hundred specimens were randomly assigned to 5 testing groups: (1) open tibial tunnel, (2) bone plug technique, (3) biodegradable interference screw, (4) dilatation technique, and (5) primary ACL reconstruction. A robotic/universal force-moment sensor testing system was used to simulate the KT-1000 (MEDmetric, San Diego, CA) and pivot-shift tests. Cyclic loading and load-to-failure testing were performed. Anterior tibial translation increased significantly with all of the techniques compared with the intact ACL (P .05). The open tunnel and dilated tunnel techniques showed significantly greater anterior tibial translation (P < .05). The results of the simulated pivot-shift test were in accordance with those of the KT-1000 test. No significant differences could be observed regarding stiffness or maximum load to failure. However, elongation was significantly lower in the primary ACL reconstruction group compared with groups 1 and 3 (P = .02 and P = .03, respectively). Filling an incomplete and incorrect tibial tunnel with a press-fit bone plug or a biodegradable interference screw in a standardized laboratory situation provided initial biomechanical properties and knee stability comparable with those of primary ACL reconstruction. In contrast, the dilatation technique or leaving the malplaced tunnel open did not restore knee kinematics adequately in this model. Backup extracortical fixation should be considered because the load to failure depends on the extracortical fixation when an undersized interference screw is used for aperture fixation. Our biomechanical results could help orthopaedic surgeons to optimize the results of primary ACL revision with incomplete, incorrect

  7. Post-Burn Skin Deformities of the Face and Neck Region in Pediatric Patients: Single-Stage Treatment Using Collagen Elastin Matrix

    Directory of Open Access Journals (Sweden)

    Çağlayan Yağmur

    2017-09-01

    Full Text Available Objective: Treating severe post-burn deformities of the face and neck region in pediatric populations is challenging because of technical difficulties (e.g., limited full thickness skin graft donor site, limited flap options, unavailability for expander placement and increased donor site morbidity (e.g., related to flap and graft donor sites. In this study, we present the single-stage treatment of severe post-burn skin deformities of the face and neck region in pediatric patients using collagen-elastin matrix (Matriderm® combined with partial thickness skin grafts. Material and Methods: The total number of cases was eight (four females, four males, and the ages were between two and 11 years. All cases were operated on for only one region. Following the release of contractures and/or excision of wide excessive/ unfavorable dermal scars, defects were reconstructed using collagen- elastin matrix (Matriderm® combined with partial-thickness skin grafts. The final functional and aesthetic results were evaluated using photography and examination. Results: The deformities were in the form of contractures and/ or excessive dermal scarring. The involved regions were the face (n=3 and neck (n=5. The grafts yielded favorable plication and texture, and no recurrence of excessive dermal scarring was observed. All contractures healed unproblematically. Two patients were re-operated on for regrafting caused by minor graft loss (5% and 12% of the total area, respectively. Conclusion: In this study, we observed that collagen elastin matrix combined with partial-thickness skin grafts provides a favorable option for the treatment of pediatric late post-burn complications in the face and neck region with limited surgical options.

  8. Single-staged resections and 3D reconstructions of the nasion, glabella, medial orbital wall, and frontal sinus and bone: Long-term outcome and review of the literature.

    Science.gov (United States)

    Ciporen, Jeremy; Lucke-Wold, Brandon P; Mendez, Gustavo; Chen, Anton; Banerjee, Amit; Akins, Paul T; Balough, Ben J

    2016-01-01

    Aesthetic facial appearance following neurosurgical ablation of frontal fossa tumors is a primary concern for patients and neurosurgeons alike. Craniofacial reconstruction procedures have drastically evolved since the development of three-dimensional computed tomography imaging and computer-assisted programming. Traditionally, two-stage approaches for resection and reconstruction were used; however, these two-stage approaches have many complications including cerebrospinal fluid leaks, necrosis, and pneumocephalus. We present two successful cases of single-stage osteoma resection and craniofacial reconstruction in a 26-year-old female and 65-year-old male. The biopolymer implants were preselected and contoured based on imaging prior to surgery. The ideal selection of appropriate flaps for reconstruction was imperative. The flaps were well vascularized and included a pedicle for easy translocation. Using a titanium mesh biopolymer implant for reconstruction in conjunction with a forehead flap proved advantageous, and the benefits of single-stage approaches were apparent. The patients recovered quickly after the surgery with complete resection of the osteoma and good aesthetic appearance. The flap adhered to the biopolymer implant, and the cosmetic appearance years after surgery remained decent. The gap between the bone and implant was less than 2 mm. The patients are highly satisfied with the symmetrical appearance of the reconstruction. Advances in technology are allowing neurosurgeons unprecedented opportunities to design complex yet feasible single-stage craniofacial reconstructions that improve a patient's quality of life by enhancing facial contours, aesthetics, and symmetry.

  9. Accelerator microanalysis

    International Nuclear Information System (INIS)

    Tuniz, C.

    1997-01-01

    Particle accelerators have been developed more than sixty years ago to investigate nuclear and atomic phenomena. A major shift toward applications of accelerators in the study of materials structure and composition in inter-disciplinary projects has been witnessed in the last two decades. The Australian Nuclear Science and Technology Organisation (ANSTO) has developed advanced research programs based on the use of particle and photon beams. Atmospheric pollution problems are investigated at the 3 MV Van de Graff accelerator using ion beam analysis techniques to detect toxic elements in aerosol particles. High temperature superconductor and semiconductor materials are characterised using the recoil of iodine and other heavy ions produced at ANTARES, the 10-MV Tandem accelerator. A heavy-ion microprobe is presently being developed at ANTARES to map elemental concentrations of specific elements with micro-size resolution. An Accelerator mass Spectrometry (AMS) system has been developed at ANSTO for the ultra-sensitive detection of Carbon-14, Iodine-129 and other long-lived radioisotopes. This AMS spectrometer is a key instrument for climate change studies and international safeguards. ANSTO is also managing the Australian Synchrotron Research program based on facilities developed at the Photon Factory (Japan) and at the Advanced Photon Source (USA). Advanced projects in biology, materials chemistry, structural condensed matter and other disciplines are being promoted by a consortium involving Australian universities and research institutions. This paper will review recent advances in the use of particle accelerators, with a particular emphasis on applications developed at ANSTO and related to problems of international concern, such as global environmental change, public health and nuclear proliferation

  10. Accelerator operations

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    Operations of the SuperHILAC, the Bevatron/Bevalac, and the 184-inch Synchrocyclotron during the period from October 1977 to September 1978 are discussed. These include ion source development, accelerator facilities, the Heavy Ion Spectrometer System, and Bevelac biomedical operations

  11. Acceleration grid

    International Nuclear Information System (INIS)

    Hemmerich, J.; Kupschus, P.; Fraenkle, H.

    1983-01-01

    The acceleration grid is used in nuclear fusion technique as an ion beam grid. It consists of perforated plates at different potentials situated behind one another in the axial movement direction of their through holes. In order to prevent interference in the perforated hole area due to thermal expansion, the perforated plates are fixed with elastic springiness (plate fields) at their edges. (DG) [de

  12. Accelerators course

    CERN Multimedia

    CERN. Geneva HR-RFA; Métral, E

    2006-01-01

    1a) Introduction and motivation 1b) History and accelerator types 2) Transverse beam dynamics 3a) Longitudinal beam dynamics 3b) Figure of merit of a synchrotron/collider 3c) Beam control 4) Main limiting factors 5) Technical challenges

  13. Accelerator operations

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    This section is concerned with the operation of both the tandem-linac system and the Dynamitron, two accelerators that are used for entirely different research. Developmental activities associated with the tandem and the Dynamitron are also treated here, but developmental activities associated with the superconducting linac are covered separately because this work is a program of technology development in its own right

  14. Accelerator update

    International Nuclear Information System (INIS)

    Anon.

    1995-01-01

    When the Accelerator Conference, combined International High Energy and US Particle versions, held in Dallas in May, was initially scheduled, progress nearby for the US Superconducting Supercollider was high on the preliminary agenda. With the SSC voted down by Congress in October 1993, this was no longer the case. However the content of the meeting, in terms of both its deep implications for ambitious new projects and the breadth of its scope, showed that the worldwide particle accelerator field is far from being moribund. A traditional feature of such accelerator conferences is the multiplicity of parallel sessions. No one person can attend all sessions, so that delegates can follow completely different paths and emerge with totally different impressions. Despite this overload, and despite the SSC cancellation, the general picture is one of encouraging progress over a wide range of major new projects throughout the world. At the same time, spinoff from, and applications of, accelerators and accelerator technology are becoming increasingly important. Centrestage is now CERN's LHC proton-proton collider, where a test string of superconducting magnets is operating over long periods at the nominal LHC field of 8.36 tesla or more. The assignment of the underground areas in the existing 27- kilometre LEP tunnel is now quasidefinitive (see page 3). For CERN's existing big machine, the LEP electron-positron collider, ongoing work concentrates on boosting performance using improved optics and bunch trains. But the main objective is the LEP2 scheme using superconducting accelerating cavities to boost the beam energy (see page 6). After some initial teething problems, production and operation of these cavities appears to have been mastered, at least under test conditions. A highlight at CERN last year was the first run with lead ions (December 1994, page 15). Handling these heavy particles with systems originally designed for protons calls for ingenuity. The SPS

  15. Lability and Basicity of Bipyridine-Carboxylate-Phosphonate Ligand Accelerate Single-Site Water Oxidation by Ruthenium-Based Molecular Catalysts.

    Science.gov (United States)

    Shaffer, David W; Xie, Yan; Szalda, David J; Concepcion, Javier J

    2017-11-01

    A critical step in creating an artificial photosynthesis system for energy storage is designing catalysts that can thrive in an assembled device. Single-site catalysts have an advantage over bimolecular catalysts because they remain effective when immobilized. Hybrid water oxidation catalysts described here, combining the features of single-site bis-phosphonate catalysts and fast bimolecular bis-carboxylate catalysts, have reached turnover frequencies over 100 s -1 , faster than both related catalysts under identical conditions. The new [(bpHc)Ru(L) 2 ] (bpH 2 cH = 2,2'-bipyridine-6-phosphonic acid-6'-carboxylic acid, L = 4-picoline or isoquinoline) catalysts proceed through a single-site water nucleophilic attack pathway. The pendant phosphonate base mediates O-O bond formation via intramolecular atom-proton transfer with a calculated barrier of only 9.1 kcal/mol. Additionally, the labile carboxylate group allows water to bind early in the catalytic cycle, allowing intramolecular proton-coupled electron transfer to lower the potentials for oxidation steps and catalysis. That a single-site catalyst can be this fast lends credence to the possibility that the oxygen evolving complex adopts a similar mechanism.

  16. Lability and Basicity of Bipyridine-Carboxylate-Phosphonate Ligand Accelerate Single-Site Water Oxidation by Ruthenium-Based Molecular Catalysts

    International Nuclear Information System (INIS)

    Shaffer, David W.; Xie, Yan; Szalda, David J.; Concepcion, Javier J.

    2017-01-01

    Here, a critical step in creating an artificial photosynthesis system for energy storage is designing catalysts that can thrive in an assembled device. Single-site catalysts have an advantage over bimolecular catalysts because they remain effective when immobilized. Hybrid water oxidation catalysts described here, combining the features of single-site bis-phosphonate catalysts and fast bimolecular bis-carboxylate catalysts, have reached turnover frequencies over 100 s –1 , faster than both related catalysts under identical conditions. The new [(bpHc)Ru(L) 2 ] (bpH 2 cH = 2,2'-bipyridine-6-phosphonic acid-6'-carboxylic acid, L = 4-picoline or isoquinoline) catalysts proceed through a single-site water nucleophilic attack pathway. The pendant phosphonate base mediates O–O bond formation via intramolecular atom-proton transfer with a calculated barrier of only 9.1 kcal/mol. Additionally, the labile carboxylate group allows water to bind early in the catalytic cycle, allowing intramolecular proton-coupled electron transfer to lower the potentials for oxidation steps and catalysis. That a single-site catalyst can be this fast lends credence to the possibility that the oxygen evolving complex adopts a similar mechanism.

  17. Quantitative targeted and retrospective data analysis of relevant pesticides, antibiotics and mycotoxins in bakery products by liquid chromatography-single-stage Orbitrap mass spectrometry.

    Science.gov (United States)

    De Dominicis, Emiliano; Commissati, Italo; Gritti, Elisa; Catellani, Dante; Suman, Michele

    2015-01-01

    In addition to 'traditional' multi-residue and multi-contaminant multiple reaction monitoring (MRM) mass spectrometric techniques devoted to quantifying a list of targeted compounds, the global food industry requires non-targeted methods capable of detecting other possible potentially hazardous compounds. Ultra-high-performance liquid chromatography combined with a single-stage Orbitrap high-resolution mass spectrometer (UHPLC-HRMS Exactive™-Orbitrap Technology) was successfully exploited for the complete selective and quantitative determination of 33 target compounds within three major cross categories (pesticides, antibiotics and mycotoxins) in bakery matrices (specifically milk, wheat flour and mini-cakes). Resolution was set at 50 000 full width at half maximum (FWHM) to achieve the right compromise between an adequate scan speed and selectivity, allowing for the limitations related to the necessary generic sample preparation approach. An exact mass with tolerance of 5 ppm and minimum peak threshold of 10 000 units were fixed as the main identification conditions, including retention time and isotopic pattern as additional criteria devoted to greatly reducing the risk of false-positive findings. The full validation for all the target analytes was performed: linearity, intermediate repeatability and recovery (28 analytes within 70-120%) were positively assessed; furthermore, limits of quantification between 5 and 100 µg kg(-1) (with most of the analytes having a limit of detection below 6 µg kg(-1)) indicate good performance, which is compatible with almost all the regulatory needs. Naturally contaminated and fortified mini-cakes, prepared through combined use of industrial and pilot plant production lines, were analysed at two different concentration levels, obtaining good overall quantitative results and providing preliminary indications of the potential of full-scan HRMS cluster analysis. The effectiveness of this analytical approach was also tested in

  18. Single or dual experimental infections with Vibrio aestuarianus and OsHV-1 in diploid and triploid Crassostrea gigas at the spat, juvenile and adult stages.

    Science.gov (United States)

    Azéma, Patrick; Travers, Marie-Agnès; Benabdelmouna, Abdellah; Dégremont, Lionel

    2016-09-01

    French production of the Pacific cupped oyster, Crassostrea gigas, is currently threatened by two pathogens, OsHV-1 and V. aestuarianus. While oysters selected for their higher resistance to OsHV-1 are now available for the industry, the impact of V. aestuarianus on such oysters is unknown, especially for triploids. In addition, experimental infection has used the virus or the bacteria alone, but there have been no investigations of dual exposure to these pathogens. This study is the first report of single or dual exposure in spat (Spat1 and Spat2), juvenile and adult naïve oysters. For each of the two stocks evaluated, unselected oysters and oysters selected for their higher resistance to OsHV-1 infection were tested, as well as their triploid siblings of the selected oysters produced using cytochalasin B. We confirmed that resistance to OsHV-1 infection and susceptibility to V. aestuarianus increased with age and size, although selected oysters were not significantly impacted by OsHV-1 whatever their ploidy, size or age. We found different mortality patterns depending on the pathogen tested. The mortality pattern was similar for oysters exposed to OsHV-1 or to both pathogens in the Spat1 trial (4months old and 1.9g). The mortality pattern was similar for oysters exposed to V. aestuarianus or to both pathogens in the Adult trial (25months old and 63.1g). Surprisingly, mortality was much higher (ranging from 75.9% to 100%), in particular for the selected oysters, for the Spat2 (8months old/3.9g) and Juvenile trials (16months old/18.4g) given a dual exposure, regardless of the level of selection for OsHV-1 and the ploidy state. Our findings highlight an important threat for oyster farmers: oysters exposed to both pathogens could experience dramatic mortality rates, even in oysters selected for their higher resistance to OsHV-1. Finally, our study demonstrated for the first time that triploid oysters were more susceptible to experimental challenges with V

  19. 14C Accelerator mass spectrometry in Brazil

    International Nuclear Information System (INIS)

    Macario, K.D.; Gomes, P.R.S.; Anjos, Roberto M.; Linares, R.; Queiroz, E.A.; Oliveira, F.M.; Cardozo, L.; Carvalho, C.R.A.

    2011-01-01

    Radiocarbon Accelerator Mass Spectrometry is an ultra-sensitive technique that enables the direct measurement of carbon isotopes in samples as small as a few milligrams. The possibility of dating or tracing rare or even compound specific carbon samples has application in many fields of science such as Archaeology, Geosciences and Biomedicine. Several kinds of material such as wood, charcoal, carbonate and bone can be chemically treated and converted to graphite to be measured in the accelerator system. The Physics Institute of Universidade Federal Fluminense (UFF), in Brazil will soon be able to perform the complete 14 C-AMS measurement of samples. At the Nuclear Chronology Laboratory (LACRON) samples are prepared and converted to carbon dioxide. A stainless steel vacuum system was constructed for carbon dioxide purification and graphitization is performed in sealed tubes in a muffle oven. Graphite samples will be analyzed in a 250 kV Single Stage Accelerator produced by National Electrostatic Corporation which will be installed in the beginning of 2012. With the sample preparation laboratory at LACRON and the SSAMS system, the Physics Institute of UFF will be the first 14 C-AMS facility in Latin America. (author)

  20. Simulations of multistage intense ion beam acceleration

    International Nuclear Information System (INIS)

    Slutz, S.A.; Poukey, J.W.

    1992-01-01

    An analytic theory for magnetically insulated, multistage acceleration of high intensity ion beams, where the diamagnetic effect due to electron flow is important, has been presented by Slutz and Desjarlais. The theory predicts the existence of two limiting voltages called V 1 (W) and V 2 (W), which are both functions of the injection energy qW of ions entering the accelerating gap. As the voltage approaches V 1 (W), unlimited beam-current density can penetrate the gap without the formation of a virtual anode because the dynamic gap goes to zero. Unlimited beam current density can penetrate an accelerating gap above V 2 (W), although a virtual anode is formed. It was found that the behavior of these limiting voltages is strongly dependent on the electron density profile. The authors have investigated the behavior of these limiting voltages numerically using the 2-D particle-in-cell (PIC) code MAGIC. Results of these simulations are consistent with the superinsulated analytic results. This is not surprising, since the ignored coordinate eliminates instabilities known to be important from studies of single stage magnetically insulated ion diodes. To investigate the effect of these instabilities the authors have simulated the problem with the 3-D PIC code QUICKSILVER, which indicates behavior that is consistent with the saturated model

  1. Phase 2 Trial of Accelerated, Hypofractionated Whole-Breast Irradiation of 39 Gy in 13 Fractions Followed by a Tumor Bed Boost Sequentially Delivering 9 Gy in 3 Fractions in Early-Stage Breast Cancer

    International Nuclear Information System (INIS)

    Kim, Ja Young; Jung, So-Youn; Lee, Seeyoun; Kang, Han-Sung; Lee, Eun Sook; Park, In Hae; Lee, Keun Seok; Ro, Jungsil; Lee, Nam Kwon; Shin, Kyung Hwan

    2013-01-01

    Purpose: To report a phase 2 trial of accelerated, hypofractionated whole-breast irradiation (AH-WBI) delivered as a daily dose of 3 Gy to the whole breast followed by a tumor bed boost. Methods and Materials: Two hundred seventy-six patients diagnosed with breast cancer (pT1-2 and pN0-1a) who had undergone breast-conserving surgery in which the operative margins were negative were treated with AH-WBI delivered as 39 Gy in 13 fractions of 3 Gy to the whole breast once daily over 5 consecutive working days, and 9 Gy in 3 sequential fractions of 3 Gy to a lumpectomy cavity, all within 3.2 weeks. Results: After a median follow-up period of 57 months (range: 27-75 months), the rate of 5-year locoregional recurrence was 1.4% (n=4), whereas that of disease-free survival was 97.4%. No grade 3 skin toxicity was reported during the follow-up period. Qualitative physician cosmetic assessments of good or excellent were noted in 82% of the patients at 2 months after the completion of AH-WBI. The global cosmetic outcome did not worsen over time, and a good or excellent cosmetic outcome was reported in 82% of the patients at 3 years. The mean pretreatment percentage breast retraction assessment was 12.00 (95% confidence interval [CI]: 11.14-12.86). The mean value of percentage breast retraction assessment increased to 13.99 (95% CI: 12.17-15.96) after 1 year and decreased to 13.54 (95% CI: 11.84-15.46) after 3 years but was not significant (P>.05). Conclusions: AH-WBI consisting of 39 Gy in 13 fractions followed by a tumor bed boost sequentially delivering 9 Gy in 3 fractions can be delivered with excellent disease control and tolerable skin toxicity in patients with early-stage breast cancer after breast-conserving surgery

  2. Phase 2 Trial of Accelerated, Hypofractionated Whole-Breast Irradiation of 39 Gy in 13 Fractions Followed by a Tumor Bed Boost Sequentially Delivering 9 Gy in 3 Fractions in Early-Stage Breast Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ja Young [Proton Therapy Center, Research Institute and Hospital, National Cancer Center, Goyang (Korea, Republic of); Jung, So-Youn; Lee, Seeyoun; Kang, Han-Sung; Lee, Eun Sook; Park, In Hae; Lee, Keun Seok; Ro, Jungsil [Center for Breast Cancer, Research Institute and Hospital, National Cancer Center, Goyang (Korea, Republic of); Lee, Nam Kwon [Proton Therapy Center, Research Institute and Hospital, National Cancer Center, Goyang (Korea, Republic of); Department of Radiation Oncology, Korea University Medical Center, Collage of Medicine, Seoul (Korea, Republic of); Shin, Kyung Hwan, E-mail: radiat@ncc.re.kr [Proton Therapy Center, Research Institute and Hospital, National Cancer Center, Goyang (Korea, Republic of); Department of Radiation Oncology, Korea University Medical Center, Collage of Medicine, Seoul (Korea, Republic of)

    2013-12-01

    Purpose: To report a phase 2 trial of accelerated, hypofractionated whole-breast irradiation (AH-WBI) delivered as a daily dose of 3 Gy to the whole breast followed by a tumor bed boost. Methods and Materials: Two hundred seventy-six patients diagnosed with breast cancer (pT1-2 and pN0-1a) who had undergone breast-conserving surgery in which the operative margins were negative were treated with AH-WBI delivered as 39 Gy in 13 fractions of 3 Gy to the whole breast once daily over 5 consecutive working days, and 9 Gy in 3 sequential fractions of 3 Gy to a lumpectomy cavity, all within 3.2 weeks. Results: After a median follow-up period of 57 months (range: 27-75 months), the rate of 5-year locoregional recurrence was 1.4% (n=4), whereas that of disease-free survival was 97.4%. No grade 3 skin toxicity was reported during the follow-up period. Qualitative physician cosmetic assessments of good or excellent were noted in 82% of the patients at 2 months after the completion of AH-WBI. The global cosmetic outcome did not worsen over time, and a good or excellent cosmetic outcome was reported in 82% of the patients at 3 years. The mean pretreatment percentage breast retraction assessment was 12.00 (95% confidence interval [CI]: 11.14-12.86). The mean value of percentage breast retraction assessment increased to 13.99 (95% CI: 12.17-15.96) after 1 year and decreased to 13.54 (95% CI: 11.84-15.46) after 3 years but was not significant (P>.05). Conclusions: AH-WBI consisting of 39 Gy in 13 fractions followed by a tumor bed boost sequentially delivering 9 Gy in 3 fractions can be delivered with excellent disease control and tolerable skin toxicity in patients with early-stage breast cancer after breast-conserving surgery.

  3. Single-shot echo-planar imaging with Nyquist ghost compensation: interleaved dual echo with acceleration (IDEA) echo-planar imaging (EPI).

    Science.gov (United States)

    Poser, Benedikt A; Barth, Markus; Goa, Pål-Erik; Deng, Weiran; Stenger, V Andrew

    2013-01-01

    Echo planar imaging (EPI) is most commonly used for blood oxygen level-dependent fMRI, owing to its sensitivity and acquisition speed. A major problem with EPI is Nyquist (N/2) ghosting, most notably at high field. EPI data are acquired under an oscillating readout gradient and hence vulnerable to gradient imperfections such as eddy current delays and off-resonance effects, as these cause inconsistencies between odd and even k-space lines after time reversal. We propose a straightforward and pragmatic method herein termed "interleaved dual echo with acceleration (IDEA) EPI": two k-spaces (echoes) are acquired under the positive and negative readout lobes, respectively, by performing phase encoding blips only before alternate readout gradients. From these two k-spaces, two almost entirely ghost free images per shot can be constructed, without need for phase correction. The doubled echo train length can be compensated by parallel imaging and/or partial Fourier acquisition. The two k-spaces can either be complex averaged during reconstruction, which results in near-perfect cancellation of residual phase errors, or reconstructed into separate images. We demonstrate the efficacy of IDEA EPI and show phantom and in vivo images at both 3 T and 7 T. Copyright © 2012 Wiley Periodicals, Inc.

  4. Accelerated treatment.

    Science.gov (United States)

    Barkley, H T

    1985-05-01

    In the first third of this century, the prevailing concept was that malignant cells had a brief period of sensitivity and radiation treatments were ideally given in overall times of 2 weeks or less. Following the Second World War, routine treatment times were extended to 5 to 8 weeks to avoid severe acute normal tissue reactions and achieve higher tumor doses. In reaction to these prolonged overall times, a series of large-fraction, shortened-overall-time clinical experiments were attempted, with disastrous normal tissue effects and poor tumor control. More recently, attempts to accelerate treatment have been accomplished by utilizing multiple fractions per day or semicontinuous irradiation. Unfortunately, the majority of these attempts have been forced by the occurrence of unacceptable normal tissue reactions to significantly reduce total dose or introduce lengthy splits in treatment. These results suggest that in our current state of knowledge accelerated schedules be reserved for use in the treatment of rapidly proliferating neoplasms or for palliation.

  5. Laser Accelerator

    Science.gov (United States)

    2014-09-01

    Photocathode emitters eject electrons from the cathode by the photoelectric effect. A drive laser source shines light energy onto a metal or...synchronized so that the electrons ejected via the photoelectric effect are properly accelerated. 15 Figure 2.4: Cross-section of a triple spoke cavity, from...2.3: Available Pulsed Magnets at PFF LANL. SP = Short Pulse. MP = Mid-Pulse, after [19] Cell No. Magnet Pulse Duration (ms) Bore (mm) 1 50 T SP 25 24

  6. DC and RF ion accelerators for MeV energies

    International Nuclear Information System (INIS)

    Urbanus, W.H.

    1990-01-01

    This thesis deals with the transport and acceleration of intense ion beams in single-ended Van de Graaff accelerators and the multiple beam rf accelerator MEQALAC (Multiple Electrostatic Quadrupole Array Linear Accelerator). Ch. 2 discusses several beam-envelope calculation techniques and describes the ion-optical components of a 1 MV, high-current, heavy-ion implantation facility and a 2 MV facility for analyzing purposes. The X-ray level of these accelerators is kept low, such that no shielding is needed, by keeping the energy of the secondary electrons sufficiently low, which is accomplished by a suppression system of small permanent magnets built in the acceleration tubes (ch. 3). Ch.'s 4,5 and 6 cover various aspects of stage II of the MEQALAC project. This stage deals with the parallel acceleration of four high-current N + beams from 40 keV to 1 MeV. Acceleration takes place in 32 rf gaps which are part of a modified interdigital H-resonator. In between the accelerating gaps, small electrostatic quadrupoles are mounted, which oppose the space charge forces of the intense ion beams. The lenses are arranged in a periodic focusing structure. A bucket-type plasma ion source is used, which produces both N + and N 2 + ions. In between the ion source and the MEQALAC section, a Low Energy Beam Transport (LEBT) section is mounted which provides for the drift space for a buncher. The latter device transforms the extracted dc beams into bunched beams which are accepted by the MEQALAC section. In ch. 4 the transport of ion beams that contain both N + and N 2 + ions, so-called mixed beams, through the LEBT section is discussed and equations for the current limit of a mixed beam are derived. Bunching of mixed N + , N 2 + beams is discussed in ch. 5. Multichannel acceleration of N + ions with the MEQALAC is discussed in ch. 6. (author). 122 refs.; 67 figs.; 1 tab

  7. Accelerating networks

    International Nuclear Information System (INIS)

    Smith, David M D; Onnela, Jukka-Pekka; Johnson, Neil F

    2007-01-01

    Evolving out-of-equilibrium networks have been under intense scrutiny recently. In many real-world settings the number of links added per new node is not constant but depends on the time at which the node is introduced in the system. This simple idea gives rise to the concept of accelerating networks, for which we review an existing definition and-after finding it somewhat constrictive-offer a new definition. The new definition provided here views network acceleration as a time dependent property of a given system as opposed to being a property of the specific algorithm applied to grow the network. The definition also covers both unweighted and weighted networks. As time-stamped network data becomes increasingly available, the proposed measures may be easily applied to such empirical datasets. As a simple case study we apply the concepts to study the evolution of three different instances of Wikipedia, namely, those in English, German, and Japanese, and find that the networks undergo different acceleration regimes in their evolution

  8. Radiocarbon accelerator mass spectrometry (AMS) sample preparation laboratory in Brazil

    International Nuclear Information System (INIS)

    Macario, Kita D.; Gomes, Paulo R. S.; Anjos, Roberto M. dos; Linares, Roberto; Queiroz, Eduardo; Oliveira, Fabiana M. de; Cardozo, Laio; Carvalho, Carla R.A.

    2011-01-01

    Full text: For decades Accelerator Mass Spectrometry has been widely used for radiocarbon measurements all over the world with application in several fields of science from archaeology to geosciences. This technique provides ultrasensitive analysis of reduced size samples or even specific compounds since sample atoms are accelerated to high energies and measured using nuclear particle detectors. Sample preparation is extremely important for accurate radiocarbon measurement and includes chemical pre-treatment to remove all possible contaminants. For beam extraction in the accelerator ion source, samples are usually converted to graphite. In this work we report a new radiocarbon sample preparation facility installed at the Physics Institute of Universidade Federal Fluminense (UFF), in Brazil. At the Nuclear Chronology Laboratory (LACRON) samples are chemically treated and converted to carbon dioxide by hydrolysis or combustion. A stainless steel based vacuum line was constructed for carbon dioxide separation and graphitization is performed in sealed quartz tubes in a muffle oven. Successful graphite production is important to provide stable beam currents and to minimize isotopic fractionation. Performance tests for graphite production are currently under way and isotopic analysis will soon be possible with the acquisition of a Single Stage AMS System by our group. The Single Stage Accelerator produced by National Electrostatic Corporation is a 250 kV air insulated accelerator especially constructed to measure the amount of 14 C in small modern graphite samples to a precision of 0.3 % or better. With the installation of such equipment in the first half of 2012, UFF will be ready to perform the 14C -AMS technique. (author)

  9. VLHC accelerator physics

    Energy Technology Data Exchange (ETDEWEB)

    Michael Blaskiewicz et al.

    2001-11-01

    A six-month design study for a future high energy hadron collider was initiated by the Fermilab director in October 2000. The request was to study a staged approach where a large circumference tunnel is built that initially would house a low field ({approx}2 T) collider with center-of-mass energy greater than 30 TeV and a peak (initial) luminosity of 10{sup 34} cm{sup -2}s{sup -1}. The tunnel was to be scoped, however, to support a future upgrade to a center-of-mass energy greater than 150 TeV with a peak luminosity of 2 x 10{sup 34} cm{sup -2} sec{sup -1} using high field ({approx} 10 T) superconducting magnet technology. In a collaboration with Brookhaven National Laboratory and Lawrence Berkeley National Laboratory, a report of the Design Study was produced by Fermilab in June 2001. 1 The Design Study focused on a Stage 1, 20 x 20 TeV collider using a 2-in-1 transmission line magnet and leads to a Stage 2, 87.5 x 87.5 TeV collider using 10 T Nb{sub 3}Sn magnet technology. The article that follows is a compilation of accelerator physics designs and computational results which contributed to the Design Study. Many of the parameters found in this report evolved during the study, and thus slight differences between this text and the Design Study report can be found. The present text, however, presents the major accelerator physics issues of the Very Large Hadron Collider as examined by the Design Study collaboration and provides a basis for discussion and further studies of VLHC accelerator parameters and design philosophies.

  10. Implementation of GPU-accelerated back projection for EPR imaging.

    Science.gov (United States)

    Qiao, Zhiwei; Redler, Gage; Epel, Boris; Qian, Yuhua; Halpern, Howard

    2015-01-01

    Electron paramagnetic resonance (EPR) Imaging (EPRI) is a robust method for measuring in vivo oxygen concentration (pO2). For 3D pulse EPRI, a commonly used reconstruction algorithm is the filtered backprojection (FBP) algorithm, in which the backprojection process is computationally intensive and may be time consuming when implemented on a CPU. A multistage implementation of the backprojection can be used for acceleration, however it is not flexible (requires equal linear angle projection distribution) and may still be time consuming. In this work, single-stage backprojection is implemented on a GPU (Graphics Processing Units) having 1152 cores to accelerate the process. The GPU implementation results in acceleration by over a factor of 200 overall and by over a factor of 3500 if only the computing time is considered. Some important experiences regarding the implementation of GPU-accelerated backprojection for EPRI are summarized. The resulting accelerated image reconstruction is useful for real-time image reconstruction monitoring and other time sensitive applications.

  11. Advanced concepts for acceleration

    International Nuclear Information System (INIS)

    Keefe, D.

    1986-07-01

    Selected examples of advanced accelerator concepts are reviewed. Such plasma accelerators as plasma beat wave accelerator, plasma wake field accelerator, and plasma grating accelerator are discussed particularly as examples of concepts for accelerating relativistic electrons or positrons. Also covered are the pulsed electron-beam, pulsed laser accelerator, inverse Cherenkov accelerator, inverse free-electron laser, switched radial-line accelerators, and two-beam accelerator. Advanced concepts for ion acceleration discussed include the electron ring accelerator, excitation of waves on intense electron beams, and two-wave combinations

  12. Positron emission tomography with 2-[18F]-Fluoro-2-Deoxy-D-Glucose for initial staging of hodgkin lymphoma: a single center experience in Brazil

    Directory of Open Access Journals (Sweden)

    Juliano Julio Cerci

    2009-06-01

    Full Text Available BACKGROUND: 2-[18F]-Fluoro-2-Deoxy-D-Glucose (FDG-PET is a well established functional imaging modality for the initial staging of Hodgkin lymphoma (HL in patients from Western Europe and North America. The reliability of FDG-PET in populations of different ethnic groups is unclear, as all investigations published to date have come from developed countries. PURPOSE: The aim of the present study was to investigate the effectiveness of FDG-PET in the initial staging of HL patients in a Brazilian population. METHODS: Eighty-two patients with newly diagnosed HL were prospectively included in the study. All patients were staged with both conventional clinical staging (CCS methods, including computed tomography (CT and whole-body FDG-PET methods. A standard of reference for the nodal regions and the extranodal organs was determined using all available information, including the CCS methods, FDG-PET, the diagnostic histology and the follow-up examinations. The results of the CCS were then compared to the FDG-PET results. RESULTS: The sensitivity of FDG-PET was higher for nodal staging than that of CT (87.8% vs. 61.6%, respectively. FDG-PET was also more sensitive than CT in regard to evaluating the extranodal organs for lymphomatous involvement (96.2% vs. 40.0%, respectively. FDG-PET detected all 16 patients who were characterized by a positive bone marrow biopsy and identified an additional 4 patients with bone marrow disease. The incorporation of FDG-PET coupled with CCS in the staging procedure upstaged 20% (17/82 of the patients and downstaged 11% (9/82 of the patients. As a result of these changes in staging, 15% (13/82 of the patients would have received a different therapeutic regimen. CONCLUSIONS: The FDG-PET method is superior to CT for the detection of nodal and extra-nodal HL. The observation that the FDG-PET method upstaged the disease was the most common result (20% of patients brought about by the addition of PET to the staging algorithm

  13. Role of staging laparoscopy in the management of Pancreatic Duct Carcinoma (PDAC): Single-center experience from a tertiary hospital in Brazil.

    Science.gov (United States)

    de Jesus, Victor Hugo Fonseca; da Costa Junior, Wilson Luiz; de Miranda Marques, Tomás Mansur Duarte; Diniz, Alessandro Landskron; de Castro Ribeiro, Héber Salvador; de Godoy, André Luis; de Farias, Igor Correia; Coimbra, Felipe José Fernandez

    2018-03-06

    Proper staging is critical to the management of pancreatic ductal carcinoma (PDAC). Laparoscopy has been used to stage patients without gross metastatic disease with variable success. We aimed to identify the frequency of patients diagnosed by laparoscopy with occult metastatic disease. Also, we looked for variables related to a higher chance of occult metastasis. Patients with PDAC submitted to staging laparoscopy either immediately before pancreatectomy or as a separate procedure between January 2010 and December 2016 were included. None presented gross metastatic disease at initial staging. We used logistic regression to search for variables associated with metastatic disease. The study population consisted of 63 patients. Among all patients, nine (16.7%) had occult metastases at laparoscopy. Unresectable tumor (Odds ratio = 18.0, P = 0.03), increasing tumor size (Odds ratio = 1.36, P = 0.01), and abdominal pain (Odds ratio = 5.6, P = 0.04) significantly predicted the risk of occult metastases in univariate analysis. In multivariate analysis, only tumor size predicted the risk of occult metastases. Laparoscopy remains a valuable tool in PDAC staging. Patients with either large or unresectable tumors, or presenting with abdominal pain present the highest risk for occult intra-abdominal metastases. © 2018 Wiley Periodicals, Inc.

  14. Accelerators and the Accelerator Community

    Energy Technology Data Exchange (ETDEWEB)

    Malamud, Ernest; Sessler, Andrew

    2008-06-01

    In this paper, standing back--looking from afar--and adopting a historical perspective, the field of accelerator science is examined. How it grew, what are the forces that made it what it is, where it is now, and what it is likely to be in the future are the subjects explored. Clearly, a great deal of personal opinion is invoked in this process.

  15. Dedicated Linear Accelerator Radiosurgery for Trigeminal Neuralgia: A Single-Center Experience in 179 Patients With Varied Dose Prescriptions and Treatment Plans

    International Nuclear Information System (INIS)

    Smith, Zachary A.; Gorgulho, Alessandra A.; Bezrukiy, Nikita; McArthur, David; Agazaryan, Nzhde; Selch, Michael T.; De Salles, Antonio A.F.

    2011-01-01

    Purpose: Dedicated linear accelerator radiosurgery (D-LINAC) has become an important treatment for trigeminal neuralgia (TN). Although the use of gamma knife continues to be established, few large series exist using D-LINAC. The authors describe their results, comparing the effects of varied target and dose regimens. Methods and Materials: Between August 1995 and January 2008, 179 patients were treated with D-LINAC radiosurgery. Ten patients (5.58%) had no clinical follow-up. The median age was 74.0 years (range, 32-90 years). A total of 39 patients had secondary or atypical pain, and 130 had idiopathic TN. Initially, 28 patients received doses between 70 and 85 Gy, with the 30% isodose line (IDL) touching the brainstem. Then, using 90 Gy, 82 consecutive patients were treated with a 30% IDL and 59 patients with a 50% IDL tangential to the pons. Results: Of 169 patients, 134 (79.3%) experienced significant relief at a mean of 28.8 months (range, 5-142 months). Average time to relief was 1.92 months (range, immediate to 6 months). A total of 31 patients (19.0%) had recurrent pain at 13.5 months. Of 87 patients with idiopathic TN without prior procedures, 79 (90.8%) had initial relief. Among 28 patients treated with 70 Gy and 30% IDL, 18 patients (64.3%) had significant relief, and 10 (35.7%) had numbness. Of the patients with 90 Gy and 30% IDL at the brainstem, 59 (79.0%) had significant relief and 48.9% had numbness. Among 59 consecutive patients with similar dose but the 50% isodoseline at the brainstem, 49 patients (88.0%) had excellent/good relief. Numbness, averaging 2.49 on a subjective scale of 1 to 5, was experienced by 49.7% of the patients, Conclusions: Increased radiation dose and volume of brainstem irradiation may improve clinical outcomes with the trade-off of trigeminal dysfunction. Further study of the implications of dose and target are needed to optimize outcomes and to minimize complications.

  16. Can neck irradiation be an alternative to neck dissection in early stage carcinoma oral tongue operated for primary alone? Experience from a single institute

    Directory of Open Access Journals (Sweden)

    Sushmita Ghoshal

    2016-07-01

    Full Text Available Purpose: To study pattern of failure, locoregional control rates (LCR and disease free survival (DFS in post-operative patients of carcinoma oral tongue, and to study the impact of nodal dissection on DFS in stage I and II patients.Methods: 102 patients of carcinoma oral tongue treated between January 2009 and December 2013 were analyzed. All patients were operated for primary disease, but neck dissection was done in 78 (76.5% patients only. However, radiation to primary site along with neck region was received by all patients. Pattern of failure, LCR and DFS were estimated.Results: At median follow up of 12 months, 10.8% patients failed locally, 10.8% in nodal region, 2.9% both at local and nodal site, and 5.9% patients failed distally. 2 year LCR and DFS was 71.2%, 90.9%, 79.5%, 0% and 55.2%, 64.4%, 57.8%, 0% in stage I, II, III, IV respectively. 2 year DFS in stage I patients, who underwent nodal dissection and post-operative radiation (14 patients was 64.3% and in whom only neck irradiation was done (15 patients, it was 45.8%, however difference was not significant (p = 0.5. But in stage II patients, 33 patients who underwent nodal dissection and post-operative radiation, 2 year DFS was 85.4% and it was 21.4% in 7 patients who underwent neck radiation only, and difference showed trend towards significance (p = 0.05. 2 or more positive lymph nodes post dissection was the only poor prognostic factor that correlated with DFS (p = 0.02Conclusion: While in stage I, neck irradiation alone can be a possible alternative to neck dissection and post-operative radiation; for stage II, neck dissection is mandatory.

  17. Randomised study on single stage laparo-endoscopic rendezvous (intra-operative ERCP procedure versus two stage approach (Pre-operative ERCP followed by laparoscopic cholecystectomy for the management of cholelithiasis with choledocholithiasis

    Directory of Open Access Journals (Sweden)

    Manash Ranjan Sahoo

    2014-01-01

    Full Text Available Introduction : The ′Rendezvous′ technique consists of laparoscopic cholecystectomy (LC standards with intra-operative cholangiography followed by endoscopic sphincterotomy. The sphincterotome is driven across the papilla through a guidewire inserted by the transcystic route. In this study, we intended to compare the two methods in a prospective randomised trial. Materials And Methods: From 2005 to 2012, we enrolled 83 patients with a diagnosis of cholecysto-choledocolithiasis. They were randomised into two groups. In ′group-A′,41 patients were treated with two stages management, first by pre-operative endoscopic retrograde cholangiopancreatography (ERCP and common bile duct (CBD clearance and second by LC. In ′group-B′, 42 patients were treated with LC and intra-operative cholangiography; and when diagnosis of choledocholithiasis was confirmed, patients had undergone one stage management of by Laparo-endoscopic Rendezvous technique. Results: In arm-A and arm-B groups, complete CBD clearance was achieved in 29 and 38 patients, respectively. Failure of the treatment in arm-A was 29% and in arm-B was 9.5%. In arm-A, selective CBD cannulation was achieved in 33 cases (80.5% and in arm-B in 39 cases (93%. In arm-Agroup, post-ERCP hyperamylasia was presented in nine patients (22% and severe pancreatitis in five patients (12% versus none of the patients (0% in arm-B group, respectively. Mean post-operative hospital stay in arm-A and arm-B groups are 10.9 and 6.8 days, respectively. Conclusion: One stage laparo-endoscopic rendezvous approach increases selective cannulation of CBD, reduces post-ERCP pancreatitis, reduces days of hospital stay, increases patient′s compliance and prevents unnecessary intervention to CBD.

  18. Pulsed Drift Tube Accelerator

    International Nuclear Information System (INIS)

    Faltens, A.

    2004-01-01

    The pulsed drift-tube accelerator (DTA) concept was revived by Joe Kwan and John Staples and is being considered for the HEDP/WDM application. It could be used to reach the full energy or as an intermediate accelerator between the diode and a high gradient accelerator such as multi-beam r.f. In the earliest LBNL HIF proposals and conceptual drivers it was used as an extended injector to reach energies where an induction linac with magnetic quadrupoles is the best choice. For HEDP, because of the very short pulse duration, the DTA could provide an acceleration rate of about 1MV/m. This note is divided into two parts: the first, a design based on existing experience; the second, an optimistic extrapolation. The first accelerates 16 parallel K + beams at a constant line charge density of 0.25(micro) C/m per beam to 10 MeV; the second uses a stripper and charge selector at around 4MeV followed by further acceleration to reach 40 MeV. Both benefit from more compact sources than the present 2MV injector source, although that beam is the basis of the first design and is a viable option. A pulsed drift-tube accelerator was the first major HIF experiment at LBNL. It was designed to produce a 2(micro)s rectangular 1 Ampere C s + beam at 2MeV. It ran comfortably at 1.6MeV for several years, then at lower voltages and currents for other experiments, and remnants of that experiment are in use in present experiments, still running 25 years later. The 1A current, completely equivalent to 1.8A K + , was chosen to be intermediate between the beamlets appropriate for a multi-beam accelerator, and a single beam of, say, 10A, at injection energies. The original driver scenarios using one large beam on each side of the reactor rapidly fell out of favor because of the very high transverse and longitudinal fields from the beam space charge, circa 1MV/cm and 250 kV/cm respectively, near the chamber and because of aberrations in focusing a large diameter beam down to a 1mm radius spot at a

  19. Scientists at Brookhaven contribute to the development of a better electron accelerator

    CERN Multimedia

    2004-01-01

    Scientists working at Brookhaven have developed a compact linear accelerator called STELLA (Staged Electron Laser Acceleration). Highly efficient, it may help electron accelerators become practical tools for applications in industry and medicine, such as radiation therapy (1 page)

  20. Accelerator neutrinos

    International Nuclear Information System (INIS)

    Autiero, D.; Declais, Y.

    2005-01-01

    In the last years neutrino physics was shaken by many important experimental results bringing solid proofs in favor of neutrino oscillations. The goal of the present and future generation of experiments at accelerators is to complete the comprehension of neutrino mixing and of the pattern of neutrino masses, perform precise measurements of all these parameters and investigate CP violation in the neutrino sector. Most of these goals will be achieved with the study of ν μ → ν e oscillations, which are mainly ruled by the still unknown mixing angle Θ 13 . A multi-step experimental strategy has to be attempted, depending on the magnitude of Θ 13 . (authors)

  1. Ring accelerators

    International Nuclear Information System (INIS)

    Gisler, G.; Faehl, R.

    1983-01-01

    We present two-dimensional simulations in (r-z) and r-theta) cylinderical geometries of imploding-liner-driven accelerators of rings of charged particles. We address issues of azimuthal and longitudinal stability of the rings. We discuss self-trapping designs in which beam injection and extraction is aided by means of external cusp fields. Our simulations are done with the 2-1/2-D particle-in-cell plasma simulation code CLINER, which combines collisionless, electromagnetic PIC capabilities with a quasi-MHD finite element package

  2. accelerating cavity

    CERN Multimedia

    On the inside of the cavity there is a layer of niobium. Operating at 4.2 degrees above absolute zero, the niobium is superconducting and carries an accelerating field of 6 million volts per metre with negligible losses. Each cavity has a surface of 6 m2. The niobium layer is only 1.2 microns thick, ten times thinner than a hair. Such a large area had never been coated to such a high accuracy. A speck of dust could ruin the performance of the whole cavity so the work had to be done in an extremely clean environment.

  3. High-current electron accelerator

    Science.gov (United States)

    Alekseyev, B. V.; Gorelikov, I. M.; Kazurov, V. I.; Mashkov, L. V.; Greshko, A. G.; Soklakov, G. I.; Fedorenko, A. I.; Yurekevich, K. B.

    1986-02-01

    A high current electron accelerator was developed and built on the basis of computer aided design calculations and electrolytic trough simulation. A 15 stage Arkadyev/Marx pulse voltage generator serves as the primary energy storing device. Each stage consists of two IK-100-0.4 capacitors connected in parallel and all immersed in transformer oil inside a metal container on electrically insulating posts. Each stage is shielded on both the positive and negative potential side. The shields, made of copper foil, not only smooth the electric field in the clearances but also constitute part of the commutating circuit and contribute to reduction of the overall generator size. The pulse voltage generator is triggered by a synchronizer through the conventional firing circuit of a TGI1-350/16 thyratron. To operate the accelerator in the nanosecond mode, the generator discharges into a diode through a twin shaping line. In this mode the accelerator can produce 0.8 MeV to 240 kA electron beams of 0.8 ns duration. To operate in the microsecond mode, the shaping line acts as storing capacitor, and the discharge gaps must be charged with polarity reversal in each stage. In this mode the accelerator can produce 0.5 MeV to 10 kA electron beams of 1 microsecond duration.

  4. Perspective of culster rapid acceleration

    International Nuclear Information System (INIS)

    Iwata, Yasushi

    1994-01-01

    Fast cluster ion beam is a new radiation beam which is characterized by high particle density and very short pulse when the composing atom group is considered as one ion pulse. As an important research which utilizes these features, the elucidation of nonlinear atomic collision dynamics is conceivable. The condition under which the nonlinear atomic collision occurs is discussed, and that in the relation of the acceleration energy of an ion beam with the particle number density is shown. The history and the present status of cluster rapid acceleration are reported. According to the balance of the electrostatic potential and bond energy of cluster ions, there is the limit in its allowable charge, and the rapid acceleration of cluster ions is made difficult. Accordingly, the method of doing preceding acceleration with an electrostatic accelerator and the acceleration to higher velocity with a RFQ accelerator (Lyons method) is the excellent acceleration system. The new charge conversion method by photoionization is proposed, and it is explained. The examples that suggest the possibility of the occurrence of nonlinear atomic collision by a single atom ion beam are introduced. (K.I.)

  5. Oral cancer trends in a single head-and-neck cancer center in the Netherlands; decline in T-stage at the time of admission

    NARCIS (Netherlands)

    Weijers, M.; Leemans, C.R.; Aartman, I.H.; Karagozoglu, K.H.; van der Waal, I.

    2011-01-01

    OBJECTIVES: In this study we evaluated the possible epidemiologic changes of oral cancer patients in the Netherlands between the years 1980-1984 and 2000-2004. We specifically studied the differences in male-female ratio, age, TNM-stage, site distribution, and alcohol and tobacco use. MATERIALS AND

  6. Performance of a generic non-axisymmetric end wall in a single stage, rotating turbine at on and off-design conditions

    CSIR Research Space (South Africa)

    Snedden, Glen C

    2010-06-01

    Full Text Available The application of non-axisymmetric end walls in turbine stages has gained wide spread acceptance as a means to improve the performance of turbines in both power generation and aero-derivative applications. Non-axisymmetric end walls are aimed...

  7. Primary Solitary Melanoma of the Lymphatic Nodes Or a Single Metastasis of Unknown Melanoma: Do We Need a New Staging System?

    Directory of Open Access Journals (Sweden)

    Georgi Tchernev

    2017-12-01

    CONCLUSION: The affection of a single lymph node in the absence of a primary tumour should not automatically lead to the conclusion that it is a single metastasis, but rather a primary melanoma of the lymph nodes, in cases of a negative PET scan, for example. In these cases, the measuring of the tumour thickness should guide the further therapeutic behaviour and determine the approach.

  8. JACoW Decoupling CERN accelerators

    CERN Document Server

    Dworak, Andrzej

    2018-01-01

    The accelerator complex at CERN is a living system. Accelerators are being dismantled, upgraded or change their purpose. New accelerators are built. The changes do not happen overnight, but when they happen they may require profound changes across the handling systems. Central timings (CT), responsible for sequencing and synchronization of accelerators, are good examples of such systems. This paper shows how over the past twenty years the changes and new requirements influenced the evolution of the CTs. It describes experience gained from using the Central Beam and Cycle Manager (CBCM) CT model, for strongly coupled accelerators, and how it led to a design of a new Dynamic Beam Negotiation (DBN) model for the AD and ELENA accelerators, which reduces the coupling, increasing accelerator independence. The paper ends with an idea how to merge strong points of both models in order to create a single generic system able to efficiently handle all CERN accelerators and provide more beam time to experiments and LHC.

  9. Optimizing accelerator technology

    CERN Multimedia

    Katarina Anthony

    2012-01-01

    A new EU-funded research and training network, oPAC, is bringing together 22 universities, research centres and industry partners to optimize particle accelerator technology. CERN is one of the network’s main partners and will host 5 early-stage researchers in the BE department.   A diamond detector that will be used for novel beam diagnostics applications in the oPAC project based at CIVIDEC. (Image courtesy of CIVIDEC.) As one of the largest Marie Curie Initial Training Networks ever funded by the EU – to the tune of €6 million – oPAC extends well beyond the particle physics community. “Accelerator physics has become integral to research in almost every scientific discipline – be it biology and life science, medicine, geology and material science, or fundamental physics,” explains Carsten P. Welsch, oPAC co-ordinator based at the University of Liverpool. “By optimizing the operation of accelerators, all of these...

  10. Removal of pharmaceuticals in pre-denitrifying MBBR – Influence of organic substrate availability in single- and three-stage configurations

    DEFF Research Database (Denmark)

    Polesel, Fabio; Torresi, Elena; Loreggian, L.

    2017-01-01

    kinetics in the different MBBRs. Experimental results revealed the possible influence of retransformation (e.g., from conjugated metabolites) and enantioselectivity on the removal of selected pharmaceuticals. In the second set of experiments, specific trends in denitrification and biotransformation...... and highest removal in S1 within the three-stage MBBR. Notably, biotransformation rate constants obtained for non-recalcitrant pharmaceuticals correlated with mean specific denitrification rates, maximum specific growth rates and observed growth yield values. Overall, these findings suggest that: (i) the long......-term exposure to tiered substrate accessibility in the three-stage configuration shaped the denitrification and biotransformation capacity of biofilms, with significant reduction under substrate limitation; (ii) biotransformation of pharmaceuticals may have occurred as a result of cometabolism by heterotrophic...

  11. Laser-driven acceleration with Bessel beam

    International Nuclear Information System (INIS)

    Imasaki, Kazuo; Li, Dazhi

    2005-01-01

    A new approach of laser-driven acceleration with Bessel beam is described. Bessel beam, in contrast to the Gaussian beam, shows diffraction-free'' characteristics in its propagation, which implies potential in laser-driven acceleration. But a normal laser, even if the Bessel beam, laser can not accelerate charged particle efficiently because the difference of velocity between the particle and photon makes cyclic acceleration and deceleration phase. We proposed a Bessel beam truncated by a set of annular slits those makes several special regions in its travelling path, where the laser field becomes very weak and the accelerated particles are possible to receive no deceleration as they undergo decelerating phase. Thus, multistage acceleration is realizable with high gradient. In a numerical computation, we have shown the potential of multistage acceleration based on a three-stage model. (author)

  12. Electron accelerators and nanomaterials - a symbiosis

    International Nuclear Information System (INIS)

    Dixit, Kavita P.; Mittal, K.C.

    2011-01-01

    Electron Accelerators and Nanomaterials share a symbiotic relationship. While electron accelerators are fast emerging as popular tools in the field of nanomaterials, use of nanomaterials so developed for sub-systems of accelerators is being explored. Material damage studies, surface modification and lithography in the nanometre scale are some of the areas in which electron accelerators are being extensively used. New methods to characterize the structure of nanoparticles use intense X-ray sources, generated from electron accelerators. Enhancement of field emission properties of carbon nanotubes using electron accelerators is another important area that is being investigated. Research on nanomaterials for use in the field of accelerators is still in the laboratory stage. Yet, new trends and emerging technologies can effectively produce materials which can be of significant use in accelerators. Properties such as enhanced field emission can be put to use in cathodes of electron guns. Superconducting properties some materials may also be useful in accelerators. This paper focusses on the electron accelerators used for synthesis, characterization and property-enhancement of nanomaterials. The details of electron accelerators used for these applications will be highlighted. Some light will be thrown on properties of nano materials which can have potential use in accelerators. (author)

  13. CAS CERN Accelerator School second advanced accelerator physics course

    International Nuclear Information System (INIS)

    Turner, S.

    1989-01-01

    The advanced course on general accelerator physics given in West Berlin closely followed that organised by the CERN Accelerator School at Oxford in September 1985 and whose proceedings were published as CERN Yellow Report 87-03 (1987). However, certain subjects were treated in a different way, improved or extended, while some new ones were introduced and it is all of these which are included in the present proceedings. The lectures include particle-photon interactions, high-brilliance lattices and single/multiple Touschek effect, while the seminars are on the major accelerators presently under construction or proposed for the near future, applications of synchrotron radiation, free-electron lasers, cosmic accelerators and crystal beams. Also included are errata, and addenda to some of the lectures, of CERN 87-03. (orig.)

  14. Stage design

    International Nuclear Information System (INIS)

    Shacter, J.

    1975-01-01

    A method is described of cycling gases through a plurality of diffusion stages comprising the steps of admitting the diffused gases from a first diffusion stage into an axial compressor, simultaneously admitting the undiffused gases from a second diffusion stage into an intermediate pressure zone of said compressor corresponding in pressure to the pressure of said undiffused gases, and then admitting the resulting compressed mixture of diffused and undiffused gases into a third diffusion stage

  15. The ATOMKI Accelerator Center

    International Nuclear Information System (INIS)

    Biri, S.; Kormany, Z.; Berzi, I.; Hunyadi, M.

    2009-01-01

    used for systematic maintenance was 328 hours. The breakdown periods amounted to only 2 hours last year. So the cyclotron was available for users during 1679 hours and the users required 1242 hours. The effectively used beam-on-target time is summarized in Table 2. The accelerated particles and the most frequent or typical energies were: proton (44%, 14.5 MeV), deuteron ( 29%, 10 MeV), alpha (16%, 12.5-15 MeV), He-3 ( 11%, 24 Mev). The renewal project of the nuclear magnetic resonance (NMR) based field stabilization system for the energy analyzing magnet has been completed. The original analogue signal processing units were replaced by a newly developed digital system. It first digitizes the low-frequency amplitude modulated signal of the marginal oscillator and then searches for the NMR-resonance. If the resonance is found then the phase of the resonance signal is measured compared to the field modulating sine wave. Based on this measured phase value the control voltage of the analyzing magnet power supply is adjusted automatically. The system hardware was built applying a C8051F041 mixed signal microcontroller, containing all the peripherals required for the measurement and control of the different components. Signal processing and power supply control is implemented by the microcontroller program and the operator can control the system through a GUI program running on a Windows PC. The new system has been in real operation since March 2009. It provides easy handling, user friendly and reliable operation with measured magnetic field stability values on the 2-3 x 10 -5 , level. The project of developing new power supplies for the low-current magnet coils of the cyclotron and the beam transport system has been continued. The prototype circuit of the new power supplies was designed, built and tested thoroughly. It contains modern high voltage tolerant IGBT components in the final stage. They are cooled by forced air, so we can get rid of the water cooling circuits used

  16. Tissue reduction of map numbers after post-exposure vaccination with single latency antigen is improved by combination with acute-stage antigens in goats

    DEFF Research Database (Denmark)

    Thakur, Aneesh; Aagaard, C.; Melvang, Heidi Mikkelsen

    compared to unvaccinated control goats. FET11 and FET13 vaccination, however, provided significantly protection with absent or very low Map numbers in tissues. No goats seroconverted in ID Screen® ELISA, except for a single goat in the unvaccinated control group at last sampling prior to euthanasia. PPDj...

  17. Oral cancer trends in a single head-and-neck cancer center in the Netherlands; decline in T-stage at the time of admission.

    Science.gov (United States)

    Weijers, Manon; Leemans, C René; Aartman, Irene H; Karagozoglu, K Hakki; van der Waal, Isaäc

    2011-11-01

    In this study we evaluated the possible epidemiologic changes of oral cancer patients in the Netherlands between the years 1980-1984 and 2000-2004. We specifically studied the differences in male-female ratio, age, TNM-stage, site distribution, and alcohol and tobacco use. Patients from the VU University Medical Center with an oral squamous cell carcinoma of the oral cavity registered in 1980-1984 (n=200), group 1, were compared to patients registered in 2000-2004 (n=184), group 2. Trends in prevalence, site distribution, TNM-stage, alcohol and tobacco use, age and gender were studied. The male-female ratio has decreased from 1.8 to 1.2. There were no differences in age between the two groups of patients. The site distribution was similar in both groups. The most commonly involved sites were the tongue and the floor of mouth. In group 2 more patients were diagnosed with a T1 tumour. There were no differences in tobacco use between the two different groups. There were much more light drinkers (0-2 drinks per day) in group 2 than in group 1, whereas there were more heavy drinkers (>4 per day) in group 1 than in group 2 (p<0.001). This was observed in both male and female patients. In our study there were no significant differences between the patients registered in the years 1980-1984 and 2000-2004 regarding the mean age of the patients, site distribution and smoking habits. The male-female ratio has decreased. In the recent group more patients were staged T1N0 and there was a strong decrease of the patients who were heavy drinkers.

  18. Body weight, hemoglobin, and absolute neutrophil count in patients with advanced-stage epithelial ovarian cancer who received chemotherapy: A single-center study

    Science.gov (United States)

    Gunawan, Y.; Winarto, H.

    2017-08-01

    The side effects of chemotherapy, a treatment modality of ovarian cancer, can disrupt overall treatment. To date, the clinical and laboratory profiles of ovarian cancer patients during chemotherapy have not been investigated. This study aimed to elucidate the clinical and laboratory profiles of patients with advanced-stage epithelial ovarian cancer who received chemotherapy in Dr. Cipto Mangunkusumo Hospital, including body mass index (BMI), hemoglobin (Hb), and absolute neutrophil count (ANC). To generate these clinical and laboratory profiles, we collected secondary data from the medical records of advanced-stage epithelial ovarian cancer patients who received six cycles of carboplatin and paclitaxel chemotherapy. We enrolled 23 patients with advanced-stage epithelial ovarian cancer patients who received six cycles of chemotherapy. Mean patient BMI before and after chemotherapy was 22.86 kg/m2 and 21.78 kg/m2, respectively. Hb levels before chemotherapy were 8-13 g/dl, with Hb Hb ≥ 10 g/dl in 22 patients (95.65%). Mean ANC was 5845.6 ± 3325.0. An average of 24.65% of patients experienced anemia after each cycle of chemotherapy. Mean ANC before chemotherapy was 3.5582 ± 3.3250. An average of 26.81% of patients had ANC Hb ≥ 10 g/dl before chemotherapy, 16 (72.72%) experienced a decrease in ANC during chemotherapy. Of the 20 patients (60.87%) with normal BMI or higher, 14 experienced a decrease in ANC during chemotherapy. The mean patient body weight decreased after six cycles of chemotherapy. Hb and ANC were persistently decreased in approximately a quarter of the 23 subjects. The decrease in ANC was not influenced by initial Hb and BMI.

  19. Californium versus cobalt brachytherapy combined with external-beam radiotherapy for IIB stage cervical cancer: long-term experience of a single institute

    OpenAIRE

    Janulionis, Ernestas; Valuckas, Konstantinas Povilas; Liukpetryte, Sarune; Samerdokiene, Vitalija; Atkocius, Vydmantas

    2015-01-01

    Purpose The purpose of this paper was to observe and compare long-term curative effects and complications of FIGO stage IIB cervical cancer patients (n = 232) treated with high-dose-rate (HDR) californium (252Cf) neutron or cobalt (60Co) photon intracavitary brachytherapy (ICBT) combined with external-beam radiotherapy (EBRT). Material and methods The EBRT dose to the small pelvis was 50 Gy in both groups. The brachytherapy component of 252Cf or 60Co was added in the 3rd week of EBRT, 5 fract...

  20. Muon Acceleration R and D

    International Nuclear Information System (INIS)

    Torun, Yagmur

    2009-01-01

    An intense muon source can be built in stages to support a uniquely broad program in high energy physics. Starting with a low-energy cooled muon beam, extraordinarily precise lepton flavor violation experiments are possible. Upgrading the facility with acceleration and a muon storage ring, one can build a Neutrino Factory that would allow a neutrino mixing physics program with unprecedented precision. Adding further acceleration and a collider ring, an energy-frontier muon collider can explore electroweak symmetry breaking and open a window to new physics.