WorldWideScience

Sample records for single sensillum screening

  1. The Benefits of Single-Touch Screens in Intersubjective Meaning Making

    OpenAIRE

    Davidsen, Jacob; Christiansen, Ellen Tove

    2013-01-01

    What are the benefits of single-touch screens? The paper presents findings of onevideo extract from ten months of observation of single-touch screen interaction among 8-9 year-old children. Recent studies of collaborative learning mediated by digital touch screens and tabletops emphasize the possibilities for equal levels of verbal and physical participation.Additionally, these studies suggest that multi-touch technologies offer more task-oriented activities compared to single-touch screen in...

  2. The Benefits of Single-Touch Screens in Intersubjective Meaning Making

    DEFF Research Database (Denmark)

    Davidsen, Jacob; Christiansen, Ellen Tove

    2013-01-01

    the possibilities for equal levels of verbal and physical participation.Additionally, these studies suggest that multi-touch technologies offer more task-oriented activities compared to single-touch screen interaction, in which discussion about turn-taking is more prevalent from the outset. In contrast, applying......What are the benefits of single-touch screens? The paper presents findings of one video extract from ten months of observation of single-touch screen interaction among 8-9 year-old children. Recent studies of collaborative learning mediated by digital touch screens and tabletops emphasize...... the Embodied Interaction Analysis, we find that the constraints of single-touch screens offer support for intersubjective meaning making in their capacity of constraining the interaction. This “grain of sand” shows how children display and construct a shared work space through embodied interaction...

  3. A single-tube screen for Salmonella and Shigella.

    Science.gov (United States)

    Procop, Gary W; Wallace, Jacqueline D; Tuohy, Marion J; Lasalvia, Margret M; Addison, Rachel M; Reller, L Barth

    2008-08-01

    Salmonella and Shigella species are routinely sought in stool specimens submitted for culture. It is a common practice to screen lactose-negative colonies by using triple sugar iron agar, lysine iron agar, and Christensen urea agar to determine if further identification is necessary. We designed and evaluated a novel combination of media, which are layered in a single tube, for screening isolates suspected to possibly represent Salmonella or Shigella. We tested this media combination with 106 Salmonella, 56 Shigella, and 56 other gram-negative bacilli. All Salmonella and Shigella isolates tested were appropriately characterized as possible Salmonella or Shigella by using an algorithm developed for use with this media combination. Similarly, 53 (95%) of 56 other gram-negative bacilli were appropriately screened as non -Salmonella and non -Shigella isolates. This unique media combination provides the most important biochemical reactions needed to screen for Salmonella and Shigella in a single-tube format, which decreases labor by two thirds (ie, 1 tube is inoculated vs 3).

  4. Single-item screening for agoraphobic symptoms : validation of a web-based audiovisual screening instrument

    NARCIS (Netherlands)

    van Ballegooijen, Wouter; Riper, Heleen; Donker, Tara; Martin Abello, Katherina; Marks, Isaac; Cuijpers, Pim

    2012-01-01

    The advent of web-based treatments for anxiety disorders creates a need for quick and valid online screening instruments, suitable for a range of social groups. This study validates a single-item multimedia screening instrument for agoraphobia, part of the Visual Screener for Common Mental Disorders

  5. Interactive Screen Experiments with Single Photons

    Science.gov (United States)

    Bronner, Patrick; Strunz, Andreas; Silberhorn, Christine; Meyn, Jan-Peter

    2009-01-01

    Single photons are used for fundamental quantum physics experiments as well as for applications. Originally being a topic of advance courses, such experiments are increasingly a subject of undergraduate courses. We provide interactive screen experiments (ISE) for supporting the work in a real laboratory, and for students who do not have access to…

  6. Primary care validation of a single-question alcohol screening test.

    Science.gov (United States)

    Smith, Peter C; Schmidt, Susan M; Allensworth-Davies, Donald; Saitz, Richard

    2009-07-01

    Unhealthy alcohol use is prevalent but under-diagnosed in primary care settings. To validate, in primary care, a single-item screening test for unhealthy alcohol use recommended by the National Institute on Alcohol Abuse and Alcoholism (NIAAA). Cross-sectional study. Adult English-speaking patients recruited from primary care waiting rooms. Participants were asked the single screening question, “How many times in the past year have you had X or more drinks in a day?”, where X is 5 for men and 4 for women, and a response of 1 or greater [corrected] is considered positive. Unhealthy alcohol use was defined as the presence of an alcohol use disorder, as determined by a standardized diagnostic interview, or risky consumption, as determined using a validated 30-day calendar method. Of 394 eligible primary care patients, 286 (73%) completed the interview. The single-question screen was 81.8% sensitive (95% confidence interval (CI) 72.5% to 88.5%) and 79.3% specific (95% CI 73.1% to 84.4%) for the detection of unhealthy alcohol use. It was slightly more sensitive (87.9%, 95% CI 72.7% to 95.2%) but was less specific (66.8%, 95% CI 60.8% to 72.3%) for the detection of a current alcohol use disorder. Test characteristics were similar to that of a commonly used three-item screen, and were affected very little by subject demographic characteristics. The single screening question recommended by the NIAAA accurately identified unhealthy alcohol use in this sample of primary care patients. These findings support the use of this brief screen in primary care.

  7. A single-question screening test for drug use in primary care.

    Science.gov (United States)

    Smith, Peter C; Schmidt, Susan M; Allensworth-Davies, Donald; Saitz, Richard

    2010-07-12

    Drug use (illicit drug use and nonmedical use of prescription drugs) is common but underrecognized in primary care settings. We validated a single-question screening test for drug use and drug use disorders in primary care. Adult patients recruited from primary care waiting rooms were asked the single screening question, "How many times in the past year have you used an illegal drug or used a prescription medication for nonmedical reasons?" A response of at least 1 time was considered positive for drug use. They were also asked the 10-item Drug Abuse Screening Test (DAST-10). The reference standard was the presence or absence of current (past year) drug use or a drug use disorder (abuse or dependence) as determined by a standardized diagnostic interview. Drug use was also determined by oral fluid testing for common drugs of abuse. Of 394 eligible primary care patients, 286 (73%) completed the interview. The single screening question was 100% sensitive (95% confidence interval [CI], 90.6%-100%) and 73.5% specific (95% CI, 67.7%-78.6%) for the detection of a drug use disorder. It was less sensitive for the detection of self-reported current drug use (92.9%; 95% CI, 86.1%-96.5%) and drug use detected by oral fluid testing or self-report (81.8%; 95% CI, 72.5%-88.5%). Test characteristics were similar to those of the DAST-10 and were affected very little by participant demographic characteristics. The single screening question accurately identified drug use in this sample of primary care patients, supporting the usefulness of this brief screen in primary care.

  8. Prevalence of problem drinking and characteristics of a single-question screen.

    Science.gov (United States)

    Stewart, Scott H; Borg, Keith T; Miller, Peter M

    2010-09-01

    Hazardous drinking and alcohol use disorders (i.e, abuse and dependence) are common in Emergency Departments (EDs). This study examined 1) the prevalence of these conditions among ED patients and 2) characteristics of a single screening question (having consumed at least five drinks for males or four for females during a single day). Data from the National Epidemiologic Survey on Alcohol and Related Conditions were analyzed. Logistic regression for clustered data was used to estimate the relative risk for past-year ED use associated with hazardous drinking, abuse, and dependence. Contingency tables were analyzed to estimate the sensitivity and specificity of the single-question screen for detecting these conditions. Hazardous drinking was not associated with ED utilization. Alcohol abuse was associated with a relative risk of 1.3 (95% confidence interval [CI] 1.1-1.5) and alcohol dependence with a relative risk of 1.9 (95% CI 1.6-2.2). For current drinkers, the single question screen was 0.96, 0.85, and 0.90 sensitive for hazardous drinking, alcohol abuse, and alcohol dependence, respectively. Individuals with a positive screen in the past year were considered at least hazardous drinkers, and specificity was 0.80, 0.64, and 0.65 for hazardous drinking, abuse, and dependence, respectively. Specificity was modestly increased in women. Most problem drinkers were hazardous drinkers, but only severe alcohol use disorders were particularly prevalent in the ED. The single heavy-drinking-day item appears sensitive for problem drinking. Positive tests must be followed by additional assessment to differentiate hazardous drinking from alcohol use disorders. Copyright © 2010. Published by Elsevier Inc.

  9. A single-question screen for rapid eye movement sleep behavior disorder

    DEFF Research Database (Denmark)

    Postuma, Ronald B; Arnulf, Isabelle; Hogl, Birgit

    2012-01-01

    Idiopathic rapid eye movement (REM) sleep behavior disorder (RBD) is a parasomnia that is an important risk factor for Parkinson's disease (PD) and Lewy body dementia. Its prevalence is unknown. One barrier to determining prevalence is that current screening tools are too long for large......-scale epidemiologic surveys. Therefore, we designed the REM Sleep Behavior Disorder Single-Question Screen (RBD1Q), a screening question for dream enactment with a simple yes/no response....

  10. Development of nondestructive screening methods for single kernel characterization of wheat

    DEFF Research Database (Denmark)

    Nielsen, J.P.; Pedersen, D.K.; Munck, L.

    2003-01-01

    predictability. However, by applying an averaging approach, in which single seed replicate measurements are mathematically simulated, a very good NIT prediction model was achieved. This suggests that the single seed NIT spectra contain hardness information, but that a single seed hardness method with higher......The development of nondestructive screening methods for single seed protein, vitreousness, density, and hardness index has been studied for single kernels of European wheat. A single kernel procedure was applied involving, image analysis, near-infrared transmittance (NIT) spectroscopy, laboratory...

  11. Recent Advances in Insect Olfaction, Specifically Regarding the Morphology and Sensory Physiology of Antennal Sensilla of the Female Sphinx Moth Manduca sexta

    Science.gov (United States)

    SHIELDS, VONNIE D.C.; HILDEBRAND, JOHN G.

    2008-01-01

    The antennal flagellum of female Manduca sexta bears eight sensillum types: two trichoid, two basiconic, one auriculate, two coeloconic, and one styliform complex sensilla. The first type of trichoid sensillum averages 34 μm in length and is innervated by two sensory cells. The second type averages 26 μm in length and is innervated by either one or three sensory cells. The first type of basiconic sensillum averages 22 μm in length, while the second type averages 15 μm in length. Both types are innervated by three bipolar sensory cells. The auriculate sensillum averages 4 μm in length and is innervated by two bipolar sensory cells. The coeloconic type-A and type-B both average 2 μm in length. The former type is innervated by five bipolar sensory cells, while the latter type, by three bipolar sensory cells. The styliform complex sensillum occurs singly on each annulus and averages 38-40 μm in length. It is formed by several contiguous sensilla. Each unit is innervated by three bipolar sensory cells. A total of 2,216 sensilla were found on a single annulus (annulus 21) of the flagellum. Electrophysiological responses from type-A trichoid sensilla to a large panel of volatile odorants revealed three different subsets of olfactory receptor cells (ORCs). Two subsets responded strongly to only a narrow range of odorants, while the third responded strongly to a broad range of odorants. Anterograde labeling of ORCs from type-A trichoid sensilla revealed that their axons projected mainly to two large female glomeruli of the antennal lobe. PMID:11754510

  12. Independent screening for single-index hazard rate models with ultrahigh dimensional features

    DEFF Research Database (Denmark)

    Gorst-Rasmussen, Anders; Scheike, Thomas

    2013-01-01

    can be viewed as the natural survival equivalent of correlation screening. We state conditions under which the method admits the sure screening property within a class of single-index hazard rate models with ultrahigh dimensional features and describe the generally detrimental effect of censoring...

  13. Double versus single reading of mammograms in a breast cancer screening programme: a cost-consequence analysis.

    Science.gov (United States)

    Posso, Margarita C; Puig, Teresa; Quintana, Ma Jesus; Solà-Roca, Judit; Bonfill, Xavier

    2016-09-01

    To assess the costs and health-related outcomes of double versus single reading of digital mammograms in a breast cancer screening programme. Based on data from 57,157 digital screening mammograms from women aged 50-69 years, we compared costs, false-positive results, positive predictive value and cancer detection rate using four reading strategies: double reading with and without consensus and arbitration, and single reading with first reader only and second reader only. Four highly trained radiologists read the mammograms. Double reading with consensus and arbitration was 15 % (Euro 334,341) more expensive than single reading with first reader only. False-positive results were more frequent at double reading with consensus and arbitration than at single reading with first reader only (4.5 % and 4.2 %, respectively; p cancer detection rate were similar for both reading strategies (4.6 and 4.2 per 1000 screens; p = 0.283). Our results suggest that changing to single reading of mammograms could produce savings in breast cancer screening. Single reading could reduce the frequency of false-positive results without changing the cancer detection rate. These results are not conclusive and cannot be generalized to other contexts with less trained radiologists. • Double reading of digital mammograms is more expensive than single reading. • Compared to single reading, double reading yields a higher proportion of false-positive results. • The cancer detection rate was similar for double and single readings. • Single reading may be a cost-effective strategy in breast cancer screening programmes.

  14. Screening for diabetic retinopathy in rural area using single-field, digital fundus images.

    Science.gov (United States)

    Ruamviboonsuk, Paisan; Wongcumchang, Nattapon; Surawongsin, Pattamaporn; Panyawatananukul, Ekchai; Tiensuwan, Montip

    2005-02-01

    To evaluate the practicability of using single-field, 2.3 million-pixel, digital fundus images for screening of diabetic retinopathy in rural areas. All diabetic patients who regularly attended the diabetic clinic at Kabcheang Community Hospital, located at 15 kilometers from the Thailand-Cambodia border, were appointed to the hospital for a 3-day diabetic retinopathy screening programme. The fundi of all patients were captured in single-field, 45 degrees, 2.3 million-pixel images using nonmydriatic digital fundus camera and then sent to a reading center in Bangkok. The fundi were also examined through dilated pupils by a retinal specialist at this hospital. The grading of diabetic retinopathy from two methods was compared for an exact agreement. The average duration of single digital fundus image capture was 2 minutes. The average file size of each image was 750 kilobytes. The average duration of single image transmission to a reading center in Bangkok via satellite was 3 minutes; via a conventional telephone line was 8 minutes. Of all 150 patients, 130 were assessed for an agreement between dilated fundus examination and digital fundus images in diagnosis of diabetic retinopathy. The exact agreement was 0.87, the weighted kappa statistics was 0.74. The sensitivity of digital fundus images in detecting diabetic retinopathy was 80%, the specificity was 96%. For diabetic macular edema the exact agreement was 0.97, the weighted kappa was 0.43, the sensitivity was 43%, and the specificity was 100%. The image capture of the nonmydriatic digital fundus camera is suitable for screening of diabetic retinopathy and single-field digital fundus images are potentially acceptable tools for the screening. The real-time image transmission via telephone lines to remote reading center, however, may not be practical for routine diabetic retinopathy screening in rural areas.

  15. Comparison of single-entry and double-entry two-step couple screening for cystic fibrosis carriers

    NARCIS (Netherlands)

    tenKate, LP; Verheij, JBGM; Wildhagen, MF; Hilderink, HBM; Kooij, L; Verzijl, JG; Habbema, JDF

    1996-01-01

    Both single-entry two-step (SETS) couple screening and double-entry two-step (DETS) couple screening have been recommended as methods to screen for cystic fibrosis gene carriers. In this paper we compare the expected results from both types of screening. In general, DETS results in a higher

  16. Screened Coulomb interactions in metallic alloys. II. Screening beyond the single-site and atomic-sphere approximations

    DEFF Research Database (Denmark)

    Ruban, Andrei; Simak, S.I.; Korzhavyi, P.A.

    2002-01-01

    -electron potential and energy. In the case of a random alloy such interactions can be accounted for only by lifting the atomic-sphere and single-site approximations, in order to include the polarization due to local environment effects. Nevertheless, a simple parametrization of the screened Coulomb interactions...... for the ordinary single-site methods, including the generalized perturbation method, is still possible. We obtained such a parametrization for bulk and surface NiPt alloys, which allows one to obtain quantitatively accurate effective interactions in this system....

  17. Use of a single alcohol screening question to identify other drug use.

    Science.gov (United States)

    Smith, Peter C; Cheng, Debbie M; Allensworth-Davies, Donald; Winter, Michael R; Saitz, Richard

    2014-06-01

    People who consume unhealthy amounts of alcohol are more likely to use illicit drugs. We tested the ability of a screening test for unhealthy alcohol use to simultaneously detect drug use. Adult English speaking patients (n=286) were enrolled from a primary care waiting room. They were asked the screening question for unhealthy alcohol use "How many times in the past year have you had X or more drinks in a day?", where X is 5 for men and 4 for women, and a response of one or more is considered positive. A standard diagnostic interview was used to determine current (past year) drug use or a drug use disorder (abuse or dependence). Oral fluid testing was also used to detect recent use of common drugs of abuse. The single screening question for unhealthy alcohol use was 67.6% sensitive (95% confidence interval [CI], 50.2-82.0%) and 64.7% specific (95% CI, 58.4-70.6%) for the detection of a drug use disorder. It was similarly insensitive for drug use detected by oral fluid testing and/or self-report. Although a patient with a drug use disorder has twice the odds of screening positive for unhealthy alcohol use compared to one without a drug use disorder, suggesting patients who screen positive for alcohol should be asked about drug use, a single screening question for unhealthy alcohol use was not sensitive or specific for the detection of other drug use or drug use disorders in a sample of primary care patients. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  18. Screening and Predicting Posttraumatic Stress and Depression in Children Following Single-Incident Trauma

    Science.gov (United States)

    Nixon, Reginald D. V.; Ellis, Alicia A.; Nehmy, Thomas J.; Ball, Shelley-Anne

    2010-01-01

    Three screening methods to predict posttraumatic stress disorder (PTSD) and depression symptoms in children following single-incident trauma were tested. Children and adolescents (N = 90; aged 7-17 years) were assessed within 4 weeks of an injury that led to hospital treatment and followed up 3 and 6 months later. Screening methods were adapted…

  19. Single-cell screening of photosynthetic growth and lactate production by cyanobacteria

    NARCIS (Netherlands)

    Hammar, P.; Angermayr, S.A.; Sjostrom, S.L.; van der Meer, J.; Hellingwerf, K.J.; Hudson, E.P.; Joensson, H.N.

    2015-01-01

    BACKGROUND: Photosynthetic cyanobacteria are attractive for a range of biotechnological applications including biofuel production. However, due to slow growth, screening of mutant libraries using microtiter plates is not feasible. RESULTS: We present a method for high-throughput, single-cell

  20. Single-cell screening of photosynthetic growth and lactate production by cyanobacteria

    DEFF Research Database (Denmark)

    Hammar, Petter; Angermayr, S. Andreas; Sjostrom, Staffan L.

    2015-01-01

    Background: Photosynthetic cyanobacteria are attractive for a range of biotechnological applications including biofuel production. However, due to slow growth, screening of mutant libraries using microtiter plates is not feasible.Results: We present a method for high-throughput, single-cell analy...

  1. Insects Can Count: Sensory Basis of Host Discrimination in Parasitoid Wasps Revealed.

    Directory of Open Access Journals (Sweden)

    Sara Ruschioni

    Full Text Available The solitary parasitoid Leptopilina heterotoma is one of the best studied organisms concerning the ecology, behaviour and physiology of host discrimination. Behavioural evidence shows that L. heterotoma uses its ovipositor to discriminate not only between parasitized and unparasitized Drosophila melanogaster larvae, but also to discriminate between hosts with different numbers of parasitoid eggs. The existing knowledge about how and when the parasitoid marks the host motivated us to unravel the chemosensory basis of host discrimination by L. heterotoma that allows it to choose the "best" host available. In this paper we report on electrophysiological recordings of multi-neural responses from the single taste sensillum on the tip of the unpaired ovipositor valve. We stimulated this sensillum with haemolymph of unparasitized, one-time-parasitized and two-times-parasitized Drosophila larvae. We demonstrate for the first time that quantitative characteristics of the neural responses to these haemolymph samples differed significantly, implying that host discrimination is encoded by taste receptor neurons in the multi-neuron coeloconic ovipositor sensillum. The activity of three of the six neurons present in the sensillum suffices for host discrimination and support the hypothesis that L. heterotoma females employ an ensemble code of parasitization status of the host.

  2. Communication disruption of guava moth (Coscinoptycha improbana) using a pheromone analog based on chain length.

    Science.gov (United States)

    Suckling, D M; Dymock, J J; Park, K C; Wakelin, R H; Jamieson, L E

    2013-09-01

    The guava moth, Coscinoptycha improbana, an Australian species that infests fruit crops in commercial and home orchards, was first detected in New Zealand in 1997. A four-component pheromone blend was identified but is not yet commercially available. Using single sensillum recordings from male antennae, we established that the same olfactory receptor neurons responded to two guava moth sex pheromone components, (Z)-11-octadecen-8-one and (Z)-12-nonadecen-9-one, and to a chain length analog, (Z)-13-eicosen-10-one, the sex pheromone of the related peach fruit moth, Carposina sasakii. We then field tested whether this non-specificity of the olfactory neurons might enable disruption of sexual communication by the commercially available analog, using male catch to synthetic lures in traps in single-tree, nine-tree and 2-ha plots. A disruptive pheromone analog, based on chain length, is reported for the first time. Trap catches for guava moth were disrupted by three polyethylene tubing dispensers releasing the analog in single-tree plots (86% disruption of control catches) and in a plots of nine trees (99% disruption). Where peach fruit moth pheromone dispensers were deployed at a density of 1000/ha in two 2-ha areas, pheromone traps for guava moth were completely disrupted for an extended period (up to 470 days in peri-urban gardens in Mangonui and 422 days in macadamia nut orchards in Kerikeri). In contrast, traps in untreated areas over 100 m away caught 302.8 ± 128.1 moths/trap in Mangonui and 327.5 ± 78.5 moths/ trap in Kerikeri. The longer chain length in the pheromone analog has greater longevity than the natural pheromone due to its lower volatility. Chain length analogs may warrant further investigation for mating disruption in Lepidoptera, and screening using single-sensillum recording is recommended.

  3. Learning Effectiveness and Cognitive Loads in Instructional Materials of Programming Language on Single and Dual Screens

    Science.gov (United States)

    Hsu, Jenq-Muh; Chang, Ting-Wen; Yu, Pao-Ta

    2012-01-01

    The teaching and learning environment in a traditional classroom typically includes a projection screen, a projector, and a computer within a digital interactive table. Instructors may apply multimedia learning materials using various information communication technologies to increase interaction effects. However, a single screen only displays a…

  4. Single reading with computer-aided detection performed by selected radiologists in a breast cancer screening program

    Energy Technology Data Exchange (ETDEWEB)

    Bargalló, Xavier, E-mail: xbarga@clinic.cat [Department of Radiology (CDIC), Hospital Clínic de Barcelona, C/ Villarroel, 170, 08036 Barcelona (Spain); Santamaría, Gorane; Amo, Montse del; Arguis, Pedro [Department of Radiology (CDIC), Hospital Clínic de Barcelona, C/ Villarroel, 170, 08036 Barcelona (Spain); Ríos, José [Biostatistics and Data Management Core Facility, IDIBAPS, (Hospital Clinic) C/ Mallorca, 183. Floor -1. Office #60. 08036 Barcelona (Spain); Grau, Jaume [Preventive Medicine and Epidemiology Unit, Hospital Clínic de Barcelona, C/ Villarroel, 170, 08036 Barcelona (Spain); Burrel, Marta; Cores, Enrique; Velasco, Martín [Department of Radiology (CDIC), Hospital Clínic de Barcelona, C/ Villarroel, 170, 08036 Barcelona (Spain)

    2014-11-15

    Highlights: • 1-The cancer detection rate of the screening program improved using a single reading protocol by experienced radiologists assisted by CAD. • 2-The cancer detection rate improved at the cost of increasing recall rate. • 3-CAD, used by breast radiologists, did not help to detect more cancers. - Abstract: Objectives: To assess the impact of shifting from a standard double reading plus arbitration protocol to a single reading by experienced radiologists assisted by computer-aided detection (CAD) in a breast cancer screening program. Methods: This was a prospective study approved by the ethics committee. Data from 21,321 consecutive screening mammograms in incident rounds (2010–2012) were read following a single reading plus CAD protocol and compared with data from 47,462 consecutive screening mammograms in incident rounds (2004–2010) that were interpreted following a double reading plus arbitration protocol. For the single reading, radiologists were selected on the basis of the appraisement of their previous performance. Results: Period 2010–2012 vs. period 2004–2010: Cancer detection rate (CDR): 6.1‰ (95% confidence interval: 5.1–7.2) vs. 5.25‰; Recall rate (RR): 7.02% (95% confidence interval: 6.7–7.4) vs. 7.24% (selected readers before arbitration) and vs. 3.94 (all readers after arbitration); Predictive positive value of recall: 8.69% vs. 13.32%. Average size of invasive cancers: 14.6 ± 9.5 mm vs. 14.3 ± 9.5 mm. Stage: 0 (22.3/26.1%); I (59.2/50.8%); II (19.2/17.1%); III (3.1/3.3%); IV (0/1.9%). Specialized breast radiologists performed better than general radiologists. Conclusions: The cancer detection rate of the screening program improved using a single reading protocol by experienced radiologists assisted by CAD, at the cost of a moderate increase of the recall rate mainly related to the lack of arbitration.

  5. Yield of chest X-ray tuberculosis screening of immigrants during the European refugee crisis of 2015: a single-centre experience

    Energy Technology Data Exchange (ETDEWEB)

    Weinrich, Julius Matthias; Sauer, Markus; Henes, Frank Oliver; Adam, Gerhard; Bannas, Peter [University Medical Center Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology and Nuclear Medicine, Hamburg (Germany); Diel, Roland [University Medical Hospital Schleswig-Holstein, Airway Research Center North (ARCN), Institute for Epidemiology, Kiel (Germany); Meywald-Walter, Karen [Public Health Department Hamburg Central, Hamburg (Germany); Schoen, Gerhard [University Medical Center Hamburg-Eppendorf, Department of Medical Biometry and Epidemiology, Hamburg (Germany)

    2017-08-15

    Our aim was to determine the prevalence of tuberculosis (TB), the number needed to screen (NNS), and the diagnostic accuracy of chest X-ray (CXR) screening to detect active pulmonary TB during the 2015 European refugee crisis. We evaluated data of all refugees who underwent CXR screening in a single-centre of one German metropolitan area in 2015. We determined the prevalence of TB, NNS, and accuracy of CXR to detect active pulmonary TB. Reference method for active TB was the database of all definite TB cases registered at the Department of Public Health. A total of 17,487 immigrants underwent single-centre CXR screening in 2015; prevalence of definite pulmonary TB was 0.103%. The NNS for detecting one case of active pulmonary TB was 1749. CXR had a sensitivity of 55.6% 95% confidence interval (CI 30.8-78.5%) and a specificity 98.3% (CI 98.1-98.5%) to reveal one case of active TB. Our single-centre study indicates that chest X-ray screening for TB during the 2015 European refugee crisis was of low yield due the low prevalence of TB and high number needed to screen, thus implicating the need for improved screening algorithms adapted to the overwhelming number of refugees. (orig.)

  6. Yield of chest X-ray tuberculosis screening of immigrants during the European refugee crisis of 2015: a single-centre experience

    International Nuclear Information System (INIS)

    Weinrich, Julius Matthias; Sauer, Markus; Henes, Frank Oliver; Adam, Gerhard; Bannas, Peter; Diel, Roland; Meywald-Walter, Karen; Schoen, Gerhard

    2017-01-01

    Our aim was to determine the prevalence of tuberculosis (TB), the number needed to screen (NNS), and the diagnostic accuracy of chest X-ray (CXR) screening to detect active pulmonary TB during the 2015 European refugee crisis. We evaluated data of all refugees who underwent CXR screening in a single-centre of one German metropolitan area in 2015. We determined the prevalence of TB, NNS, and accuracy of CXR to detect active pulmonary TB. Reference method for active TB was the database of all definite TB cases registered at the Department of Public Health. A total of 17,487 immigrants underwent single-centre CXR screening in 2015; prevalence of definite pulmonary TB was 0.103%. The NNS for detecting one case of active pulmonary TB was 1749. CXR had a sensitivity of 55.6% 95% confidence interval (CI 30.8-78.5%) and a specificity 98.3% (CI 98.1-98.5%) to reveal one case of active TB. Our single-centre study indicates that chest X-ray screening for TB during the 2015 European refugee crisis was of low yield due the low prevalence of TB and high number needed to screen, thus implicating the need for improved screening algorithms adapted to the overwhelming number of refugees. (orig.)

  7. Development of droplets‐based microfluidic systems for single­‐cell high‐throughput screening

    DEFF Research Database (Denmark)

    Chen, Jun; Jensen, Thomas Glasdam; Godina, Alexei

    2014-01-01

    High-throughput screening (HTS) plays an important role in the development of microbial cell factories. One of the most popular approaches is to use microplates combined with the application of robotics, liquid handling and sophisticated detection methods. However, these workstations require large...... investment, and a logarithmic increase to screen large combinatorial libraries over the decades also makes it gradually out of depth. Here, we are trying to develop a feasible high‐throughput system that uses microfluidics to compartmentalize a single cell for propagation and analysis in monodisperse...... picoliter aqueous droplets surround by an immiscible fluorinated oil phase. Our aim is to use this system to facilitate the screening process for both the biotechnology and food industry....

  8. Yield of chest X-ray tuberculosis screening of immigrants during the European refugee crisis of 2015: a single-centre experience.

    Science.gov (United States)

    Weinrich, Julius Matthias; Diel, Roland; Sauer, Markus; Henes, Frank Oliver; Meywald-Walter, Karen; Adam, Gerhard; Schön, Gerhard; Bannas, Peter

    2017-08-01

    Our aim was to determine the prevalence of tuberculosis (TB), the number needed to screen (NNS), and the diagnostic accuracy of chest X-ray (CXR) screening to detect active pulmonary TB during the 2015 European refugee crisis. We evaluated data of all refugees who underwent CXR screening in a single-centre of one German metropolitan area in 2015. We determined the prevalence of TB, NNS, and accuracy of CXR to detect active pulmonary TB. Reference method for active TB was the database of all definite TB cases registered at the Department of Public Health. A total of 17,487 immigrants underwent single-centre CXR screening in 2015; prevalence of definite pulmonary TB was 0.103%. The NNS for detecting one case of active pulmonary TB was 1749. CXR had a sensitivity of 55.6% [95% confidence interval (CI) 30.8-78.5%) and a specificity 98.3% (CI 98.1-98.5%) to reveal one case of active TB. Our single-centre study indicates that chest X-ray screening for TB during the 2015 European refugee crisis was of low yield due the low prevalence of TB and high number needed to screen, thus implicating the need for improved screening algorithms adapted to the overwhelming number of refugees. • Prevalence of pulmonary tuberculosis (TB) among refugees in 2015 was low (0.103%). • The number needed to screen to detect one case of active pulmonary TB was 1749. • Tuberculosis X-ray screening resulted in a low sensitivity and high specificity. • Tuberculosis X-ray screening during the European refugee crisis is of low yield. • Improved screening algorithms are needed due to the overwhelming the number of refugees.

  9. Tuberculosis screening among homeless persons with AIDS living in single-room-occupancy hotels.

    Science.gov (United States)

    Layton, M C; Cantwell, M F; Dorsinville, G J; Valway, S E; Onorato, I M; Frieden, T R

    1995-11-01

    Congregate facilities for homeless persons with the acquired immunodeficiency syndrome (AIDS) are often endemic for tuberculosis. We evaluated tuberculosis screening methods at single-room-occupancy hotels housing persons with AIDS. Residents were screened by cross matching the New York City Tuberculosis Registry, interviewing for tuberculosis history, skin testing, and chest radiography. Cases were classified as either previously or newly diagnosed. Among the 106 participants, 16 (15%) previously diagnosed tuberculosis cases were identified. Participants' tuberculosis histories were identified by the questionnaire (100%) or by registry match (69%). Eight participants (50%) were noncompliant with therapy. These findings prompted the establishment of a directly observed therapy program on site.

  10. Laser-Induced Fluorescence Detection in High-Throughput Screening of Heterogeneous Catalysts and Single Cells Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Su, Hui [Iowa State Univ., Ames, IA (United States)

    2001-01-01

    Laser-induced fluorescence detection is one of the most sensitive detection techniques and it has found enormous applications in various areas. The purpose of this research was to develop detection approaches based on laser-induced fluorescence detection in two different areas, heterogeneous catalysts screening and single cell study. First, the author introduced laser-induced imaging (LIFI) as a high-throughput screening technique for heterogeneous catalysts to explore the use of this high-throughput screening technique in discovery and study of various heterogeneous catalyst systems. This scheme is based on the fact that the creation or the destruction of chemical bonds alters the fluorescence properties of suitably designed molecules. By irradiating the region immediately above the catalytic surface with a laser, the fluorescence intensity of a selected product or reactant can be imaged by a charge-coupled device (CCD) camera to follow the catalytic activity as a function of time and space. By screening the catalytic activity of vanadium pentoxide catalysts in oxidation of naphthalene, they demonstrated LIFI has good detection performance and the spatial and temporal resolution needed for high-throughput screening of heterogeneous catalysts. The sample packing density can reach up to 250 x 250 subunits/cm2 for 40-μm wells. This experimental set-up also can screen solid catalysts via near infrared thermography detection. In the second part of this dissertation, the author used laser-induced native fluorescence coupled with capillary electrophoresis (LINF-CE) and microscope imaging to study the single cell degranulation. On the basis of good temporal correlation with events observed through an optical microscope, they have identified individual peaks in the fluorescence electropherograms as serotonin released from the granular core on contact with the surrounding fluid.

  11. 'Do you think you suffer from depression?' Reevaluating the use of a single item question for the screening of depression in older primary care patients

    DEFF Research Database (Denmark)

    Ayalon, Liat; Goldfracht, Margalit; Bech, Per

    2010-01-01

    OBJECTIVES: The majority of older adults seek depression treatment in primary care. Despite impressive efforts to integrate depression treatment into primary care, depression often remains undetected. The overall goal of the present study was to compare a single item screening for depression...... to existing depression screening tools. METHODS: A cross sectional sample of 153 older primary care patients. Participants completed several depression-screening measures (e.g. a single depression screen, Patient Health Questionnaire-9, Major Depression Inventory, Visual Analogue Scale). Measures were......: An easy way to detect depression in older primary care patients would be asking the single question, 'do you think you suffer from depression?'...

  12. Variations in screening outcome among pairs of screening radiologists at non-blinded double reading of screening mammograms: a population-based study

    NARCIS (Netherlands)

    Klompenhouwer, E. G.; Duijm, L. E. M.; Voogd, A. C.; den Heeten, G. J.; Nederend, J.; Jansen, F. H.; Broeders, M. J. M.

    2014-01-01

    Substantial inter-observer variability in screening mammography interpretation has been reported at single reading. However, screening results of pairs of screening radiologists have not yet been published. We determined variations in screening performances among pairs of screening radiologists at

  13. Laser-Induced Fluorescence Detection in High-Throughput Screening of Heterogeneous Catalysts and Single Cells Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Su, Hui [Iowa State Univ., Ames, IA (United States)

    2001-01-01

    Laser-induced fluorescence detection is one of the most sensitive detection techniques and it has found enormous applications in various areas. The purpose of this research was to develop detection approaches based on laser-induced fluorescence detection in two different areas, heterogeneous catalysts screening and single cell study. First, we introduced laser-induced imaging (LIFI) as a high-throughput screening technique for heterogeneous catalysts to explore the use of this high-throughput screening technique in discovery and study of various heterogeneous catalyst systems. This scheme is based on the fact that the creation or the destruction of chemical bonds alters the fluorescence properties of suitably designed molecules. By irradiating the region immediately above the catalytic surface with a laser, the fluorescence intensity of a selected product or reactant can be imaged by a charge-coupled device (CCD) camera to follow the catalytic activity as a function of time and space. By screening the catalytic activity of vanadium pentoxide catalysts in oxidation of naphthalene, we demonstrated LIFI has good detection performance and the spatial and temporal resolution needed for high-throughput screening of heterogeneous catalysts. The sample packing density can reach up to 250 x 250 subunits/cm2 for 40-μm wells. This experimental set-up also can screen solid catalysts via near infrared thermography detection.

  14. Laser-Induced Fluorescence Detection in High-Throughput Screening of Heterogeneous Catalysts and Single Cells Analysis

    International Nuclear Information System (INIS)

    Hui Su

    2001-01-01

    Laser-induced fluorescence detection is one of the most sensitive detection techniques and it has found enormous applications in various areas. The purpose of this research was to develop detection approaches based on laser-induced fluorescence detection in two different areas, heterogeneous catalysts screening and single cell study. First, we introduced laser-induced imaging (LIFI) as a high-throughput screening technique for heterogeneous catalysts to explore the use of this high-throughput screening technique in discovery and study of various heterogeneous catalyst systems. This scheme is based on the fact that the creation or the destruction of chemical bonds alters the fluorescence properties of suitably designed molecules. By irradiating the region immediately above the catalytic surface with a laser, the fluorescence intensity of a selected product or reactant can be imaged by a charge-coupled device (CCD) camera to follow the catalytic activity as a function of time and space. By screening the catalytic activity of vanadium pentoxide catalysts in oxidation of naphthalene, we demonstrated LIFI has good detection performance and the spatial and temporal resolution needed for high-throughput screening of heterogeneous catalysts. The sample packing density can reach up to 250 x 250 subunits/cm(sub 2) for 40-(micro)m wells. This experimental set-up also can screen solid catalysts via near infrared thermography detection

  15. Identifying harmful drinking using a single screening question in a psychiatric consultation-liaison population.

    Science.gov (United States)

    Massey, Suena H; Norris, Lorenzo; Lausin, Melissa; Nwaneri, Chinyere; Lieberman, Daniel Z

    2011-01-01

    Harmful drinking is common in medical inpatients, yet commonly missed due in part to time pressures. A screening question about past year heavy drinking recommended by the National Institute on Alcohol Abuse and Alcoholism (NIAAA) has been validated in primary care and emergency room settings. We tested the psychometric properties of a modified single screening question (SSQ) in hospitalized patients referred to a consultation-liaison service. A psychiatry attending (n = 40), a psychiatry resident (n = 30) and a medical student (n = 30) administered the SSQ, followed by a self-report 10-item Alcohol Use Disorders Identification Test (AUDIT) to a sample of 100 consultation-liaison patients who were able to give informed consent for participation. Using the AUDIT as a reference, the sensitivity and specificity of the SSQ to detect harmful drinking in this sample were .96 and .82, respectively. Gender differences in specificity were not found. The single question also had a strong correlation with dependence (r(b) = .457, p past year heavy drinking can rapidly identify harmful drinking in alert nonpsychotic consultation-liaison patients. Copyright © 2011 The Academy of Psychosomatic Medicine. Published by Elsevier Inc. All rights reserved.

  16. Ultrasensitive Single Fluorescence-Labeled Probe-Mediated Single Universal Primer-Multiplex-Droplet Digital Polymerase Chain Reaction for High-Throughput Genetically Modified Organism Screening.

    Science.gov (United States)

    Niu, Chenqi; Xu, Yuancong; Zhang, Chao; Zhu, Pengyu; Huang, Kunlun; Luo, Yunbo; Xu, Wentao

    2018-05-01

    As genetically modified (GM) technology develops and genetically modified organisms (GMOs) become more available, GMOs face increasing regulations and pressure to adhere to strict labeling guidelines. A singleplex detection method cannot perform the high-throughput analysis necessary for optimal GMO detection. Combining the advantages of multiplex detection and droplet digital polymerase chain reaction (ddPCR), a single universal primer-multiplex-ddPCR (SUP-M-ddPCR) strategy was proposed for accurate broad-spectrum screening and quantification. The SUP increases efficiency of the primers in PCR and plays an important role in establishing a high-throughput, multiplex detection method. Emerging ddPCR technology has been used for accurate quantification of nucleic acid molecules without a standard curve. Using maize as a reference point, four heterologous sequences ( 35S, NOS, NPTII, and PAT) were selected to evaluate the feasibility and applicability of this strategy. Surprisingly, these four genes cover more than 93% of the transgenic maize lines and serve as preliminary screening sequences. All screening probes were labeled with FAM fluorescence, which allows the signals from the samples with GMO content and those without to be easily differentiated. This fiveplex screening method is a new development in GMO screening. Utilizing an optimal amplification assay, the specificity, limit of detection (LOD), and limit of quantitation (LOQ) were validated. The LOD and LOQ of this GMO screening method were 0.1% and 0.01%, respectively, with a relative standard deviation (RSD) < 25%. This method could serve as an important tool for the detection of GM maize from different processed, commercially available products. Further, this screening method could be applied to other fields that require reliable and sensitive detection of DNA targets.

  17. Screened ion-ion interaction in mercury-chain compounds: Single chain

    International Nuclear Information System (INIS)

    Mohan, M.M.; Griffin, A.

    1985-01-01

    At room temperature, the mercury chains in Hg/sub 3-delta/AsF 6 exhibit phonons characteristic of a one-dimensional lattice. We calculate the screening of the Hg ion-ion interaction in a single chain by electrons moving in a cylindrical potential of finite radius, within the random-phase approximation. The resulting Bohm-Staver-type expression for the phonon velocity is (Z 2 mN/sub I//MN/sub e/)/sup 1/2/v/sub F/, where Z is the Hg ionic charge and N/sub I/ (N/sub e/) is the number of ions (electrons) per unit length. Use of the Tomonaga-Luttinger solution for the electronic response function (keeping only the small-momentum scattering processes) just renormalizes the Fermi velocity in this expression

  18. iScreen: Image-Based High-Content RNAi Screening Analysis Tools.

    Science.gov (United States)

    Zhong, Rui; Dong, Xiaonan; Levine, Beth; Xie, Yang; Xiao, Guanghua

    2015-09-01

    High-throughput RNA interference (RNAi) screening has opened up a path to investigating functional genomics in a genome-wide pattern. However, such studies are often restricted to assays that have a single readout format. Recently, advanced image technologies have been coupled with high-throughput RNAi screening to develop high-content screening, in which one or more cell image(s), instead of a single readout, were generated from each well. This image-based high-content screening technology has led to genome-wide functional annotation in a wider spectrum of biological research studies, as well as in drug and target discovery, so that complex cellular phenotypes can be measured in a multiparametric format. Despite these advances, data analysis and visualization tools are still largely lacking for these types of experiments. Therefore, we developed iScreen (image-Based High-content RNAi Screening Analysis Tool), an R package for the statistical modeling and visualization of image-based high-content RNAi screening. Two case studies were used to demonstrate the capability and efficiency of the iScreen package. iScreen is available for download on CRAN (http://cran.cnr.berkeley.edu/web/packages/iScreen/index.html). The user manual is also available as a supplementary document. © 2014 Society for Laboratory Automation and Screening.

  19. Current Status of Comprehensive Chromosome Screening for Elective Single-Embryo Transfer

    Directory of Open Access Journals (Sweden)

    Ming-Yih Wu

    2014-01-01

    Full Text Available Most in vitro fertilization (IVF experts and infertility patients agree that the most ideal assisted reproductive technology (ART outcome is to have a healthy, full-term singleton born. To this end, the most reliable policy is the single-embryo transfer (SET. However, unsatisfactory results in IVF may result from plenty of factors, in which aneuploidy associated with advanced maternal age is a major hurdle. Throughout the past few years, we have got a big leap in advancement of the genetic screening of embryos on aneuploidy, translocation, or mutations. This facilitates a higher success rate in IVF accompanied by the policy of elective SET (eSET. As the cost is lowering while the scale of genome characterization continues to be up over the recent years, the contemporary technologies on trophectoderm biopsy and freezing-thaw, comprehensive chromosome screening (CCS with eSET appear to be getting more and more popular for modern IVF centers. Furthermore, evidence has showen that, by these avant-garde techniques (trophectoderm biopsy, vitrification, and CCS, older infertile women with the help of eSET may have an opportunity to increase the success of their live birth rates approaching those reported in younger infertility patients.

  20. Dynamical modeling of the moth pheromone-sensitive olfactory receptor neuron within its sensillar environment.

    Directory of Open Access Journals (Sweden)

    Yuqiao Gu

    Full Text Available In insects, olfactory receptor neurons (ORNs, surrounded with auxiliary cells and protected by a cuticular wall, form small discrete sensory organs--the sensilla. The moth pheromone-sensitive sensillum is a well studied example of hair-like sensillum that is favorable to both experimental and modeling investigations. The model presented takes into account both the molecular processes of ORNs, i.e. the biochemical reactions and ionic currents giving rise to the receptor potential, and the cellular organization and compartmentalization of the organ represented by an electrical circuit. The number of isopotential compartments needed to describe the long dendrite bearing pheromone receptors was determined. The transduction parameters that must be modified when the number of compartments is increased were identified. This model reproduces the amplitude and time course of the experimentally recorded receptor potential. A first complete version of the model was analyzed in response to pheromone pulses of various strengths. It provided a quantitative description of the spatial and temporal evolution of the pheromone-dependent conductances, currents and potentials along the outer dendrite and served to determine the contribution of the various steps in the cascade to its global sensitivity. A second simplified version of the model, utilizing a single depolarizing conductance and leak conductances for repolarizing the ORN, was derived from the first version. It served to analyze the effects on the sensory properties of varying the electrical parameters and the size of the main sensillum parts. The consequences of the results obtained on the still uncertain mechanisms of olfactory transduction in moth ORNs--involvement or not of G-proteins, role of chloride and potassium currents--are discussed as well as the optimality of the sensillum organization, the dependence of biochemical parameters on the neuron spatial extension and the respective contributions

  1. Vitrified/warmed single blastocyst transfer in preimplantation genetic diagnosis/preimplantation genetic screening cycles.

    Science.gov (United States)

    Huang, Jin; Li, Rong; Lian, Ying; Chen, Lixue; Shi, Xiaodan; Qiao, Jie; Liu, Ping

    2015-01-01

    To investigate the single blastocyst transfer in preimplantation genetic diagnosis (PGD)/preimplantation genetic screening (PGS) cycles. 80 PGD/PGS cycles undergoing blastocyst biopsy were studied. There were 88 warming cycles during the study period. Only one warmed blastocyst was transferred per cycle. The outcomes were followed up to the infants were born. The embryo implantation rate was 54.55% (48/88). The clinical pregnancy rate was 54.55% (48/88) per transfer cycle and 60% (48/80) per initial PGD/PGS cycle. There was no multi-pregnant in this study. The live birth rate was 42.05% (37/88) per transfer cycle and 46.25% (37/80) per initial PGD/PGS cycle. In PGD/PGS cycles, single blastocyst transfer reduces the multiple pregnancy rate without affecting the clinical outcomes.

  2. Controlled single-blind clinical evaluation of low-dose mammographic screen: film systems

    International Nuclear Information System (INIS)

    Sickles, E.A.; Genant, H.K.

    1979-01-01

    The ability of five low-dose mammographic screen-film systems to portray normal and abnormal breast structures was evaluated in parallel with a study of physical image properties. Single-blind evaluations of the visibility of normal breast architecture, mass lesions, and calcifications were made on the mammograms of 100 patients radiographed with each of the systems. There was increased noise and slightly poorer resolution of the faster recording systems, but there was no difference in final diagnostic impressions among the five systems. These results suggest that the faster systems will result in substantial dose reduction without sacrificing diagnostic accuracy

  3. Screening of a Brassica napus bacterial artificial chromosome library using highly parallel single nucleotide polymorphism assays

    Science.gov (United States)

    2013-01-01

    Background Efficient screening of bacterial artificial chromosome (BAC) libraries with polymerase chain reaction (PCR)-based markers is feasible provided that a multidimensional pooling strategy is implemented. Single nucleotide polymorphisms (SNPs) can be screened in multiplexed format, therefore this marker type lends itself particularly well for medium- to high-throughput applications. Combining the power of multiplex-PCR assays with a multidimensional pooling system may prove to be especially challenging in a polyploid genome. In polyploid genomes two classes of SNPs need to be distinguished, polymorphisms between accessions (intragenomic SNPs) and those differentiating between homoeologous genomes (intergenomic SNPs). We have assessed whether the highly parallel Illumina GoldenGate® Genotyping Assay is suitable for the screening of a BAC library of the polyploid Brassica napus genome. Results A multidimensional screening platform was developed for a Brassica napus BAC library which is composed of almost 83,000 clones. Intragenomic and intergenomic SNPs were included in Illumina’s GoldenGate® Genotyping Assay and both SNP classes were used successfully for screening of the multidimensional BAC pools of the Brassica napus library. An optimized scoring method is proposed which is especially valuable for SNP calling of intergenomic SNPs. Validation of the genotyping results by independent methods revealed a success of approximately 80% for the multiplex PCR-based screening regardless of whether intra- or intergenomic SNPs were evaluated. Conclusions Illumina’s GoldenGate® Genotyping Assay can be efficiently used for screening of multidimensional Brassica napus BAC pools. SNP calling was specifically tailored for the evaluation of BAC pool screening data. The developed scoring method can be implemented independently of plant reference samples. It is demonstrated that intergenomic SNPs represent a powerful tool for BAC library screening of a polyploid genome

  4. Single Molecule Screening of Disease DNA Without Amplification

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji-Young [Iowa State Univ., Ames, IA (United States)

    2006-01-01

    The potential of single molecule detection as an analysis tool in biological and medical fields is well recognized today. This fast evolving technique will provide fundamental sensitivity to pick up individual pathogen molecules, and therefore contribute to a more accurate diagnosis and a better chance for a complete cure. Many studies are being carried out to successfully apply this technique in real screening fields. In this dissertation, several attempts are shown that have been made to test and refine the application of the single molecule technique as a clinical screening method. A basic applicability was tested with a 100% target content sample, using electrophoretic mobility and multiple colors as identification tools. Both electrophoretic and spectral information of individual molecule were collected within a second, while the molecule travels along the flow in a capillary. Insertion of a transmission grating made the recording of the whole spectrum of a dye-stained molecule possible without adding complicated instrumental components. Collecting two kinds of information simultaneously and combining them allowed more thorough identification, up to 98.8% accuracy. Probing mRNA molecules with fluorescently labeled cDNA via hybridization was also carried out. The spectral differences among target, probe, and hybrid were interpreted in terms of dispersion distances after transmission grating, and used for the identification of each molecule. The probes were designed to have the least background when they are free, but have strong fluorescence after hybridization via fluorescence resonance energy transfer. The mRNA-cDNA hybrids were further imaged in whole blood, plasma, and saliva, to test how far a crude preparation can be tolerated. Imaging was possible with up to 50% of clear bio-matrix contents, suggesting a simple lysis and dilution would be sufficient for imaging for some cells. Real pathogen DNA of human papillomavirus (HPV) type-I6 in human genomic DNA

  5. The diagnostic accuracy of single- and five-field fundus photography in diabetic retinopathy screening by primary care physicians.

    Science.gov (United States)

    Srihatrai, Parinya; Hlowchitsieng, Thanita

    2018-01-01

    The aim is to evaluate the diagnostic accuracy of digital fundus photography in diabetic retinopathy (DR) screening at a single university hospital. This was a cross-sectional hospital-based study. One hundred and ninety-eight diabetic patients were recruited for comprehensive eye examination by two ophthalmologists. Five-field fundus photographs were taken with a digital, nonmydriatic fundus camera, and trained primary care physicians then graded the severity of DR present by single-field 45° and five-field fundus photography. Sensitivity and specificity of DR grading were reported using the findings from the ophthalmologists' examinations as a gold standard. When fundus photographs of the participants' 363 eyes were analyzed for the presence of DR, there was substantial agreement between the two primary care physicians, κ = 0.6226 for single-field and 0.6939 for five-field photograph interpretation. The sensitivity and specificity of DR detection with single-field photographs were 70.7% (95% Confidence interval [CI]; 60.2%-79.7%) and 99.3% (95% CI; 97.4%-99.9%), respectively. Sensitivity and specificity for five-field photographs were 84.5% (95% CI; 75.8%-91.1%) and 98.6% (95% CI; 96.5%-99.6%), respectively. The receiver operating characteristic was 0.85 (0.80-0.90) for single-field photographs and 0.92 (0.88-0.95) for five-field photographs. The sensitivity and specificity of fundus photographs for DR detection by primary care physicians were acceptable. Single- and five-field digital fundus photography each represent a convenient screening tool with acceptable accuracy.

  6. Development of a high throughput single-particle screening for inorganic semiconductor nanorods as neural voltage sensor

    Science.gov (United States)

    Kuo, Yung; Park, Kyoungwon; Li, Jack; Ingargiola, Antonino; Park, Joonhyuck; Shvadchak, Volodymyr; Weiss, Shimon

    2017-08-01

    Monitoring membrane potential in neurons requires sensors with minimal invasiveness, high spatial and temporal (sub-ms) resolution, and large sensitivity for enabling detection of sub-threshold activities. While organic dyes and fluorescent proteins have been developed to possess voltage-sensing properties, photobleaching, cytotoxicity, low sensitivity, and low spatial resolution have obstructed further studies. Semiconductor nanoparticles (NPs), as prospective voltage sensors, have shown excellent sensitivity based on Quantum confined Stark effect (QCSE) at room temperature and at single particle level. Both theory and experiment have shown their voltage sensitivity can be increased significantly via material, bandgap, and structural engineering. Based on theoretical calculations, we synthesized one of the optimal candidates for voltage sensors: 12 nm type-II ZnSe/CdS nanorods (NRs), with an asymmetrically located seed. The voltage sensitivity and spectral shift were characterized in vitro using spectrally-resolved microscopy using electrodes grown by thin film deposition, which "sandwich" the NRs. We characterized multiple batches of such NRs and iteratively modified the synthesis to achieve higher voltage sensitivity (ΔF/F> 10%), larger spectral shift (>5 nm), better homogeneity, and better colloidal stability. Using a high throughput screening method, we were able to compare the voltage sensitivity of our NRs with commercial spherical quantum dots (QDs) with single particle statistics. Our method of high throughput screening with spectrally-resolved microscope also provides a versatile tool for studying single particles spectroscopy under field modulation.

  7. An improved single cell ultrahigh throughput screening method based on in vitro compartmentalization.

    Directory of Open Access Journals (Sweden)

    Fuqiang Ma

    Full Text Available High-throughput screening is a key technique in discovery and engineering of enzymes. In vitro compartmentalization based fluorescence-activated cell sorting (IVC-FACS has recently emerged as a powerful tool for ultrahigh-throughput screening of biocatalysts. However, the accuracy of current IVC-FACS assays is severely limited by the wide polydispersity of micro-reactors generated by homogenizing. Here, an improved protocol based on membrane-extrusion technique was reported to generate the micro-reactors in a more uniform manner. This crucial improvement enables ultrahigh-throughput screening of enzymatic activity at a speed of >10⁸ clones/day with an accuracy that could discriminate as low as two-fold differences in enzymatic activity inside the micro-reactors, which is higher than similar IVC-FACS systems ever have reported. The enzymatic reaction in the micro-reactors has very similar kinetic behavior compared to the bulk reaction system and shows wide dynamic range. By using the modified IVC-FACS, E. coli cells with esterase activity could be enriched 330-fold from large excesses of background cells through a single round of sorting. The utility of this new IVC-FACS system was further illustrated by the directed evolution of thermophilic esterase AFEST. The catalytic activity of the very efficient esterase was further improved by ∼2-fold, resulting in several improved mutants with k(cat/K(M values approaching the diffusion-limited efficiency of ∼10⁸ M⁻¹s⁻¹.

  8. A Multiplexed Single-Cell CRISPR Screening Platform Enables Systematic Dissection of the Unfolded Protein Response. | Office of Cancer Genomics

    Science.gov (United States)

    Functional genomics efforts face tradeoffs between number of perturbations examined and complexity of phenotypes measured. We bridge this gap with Perturb-seq, which combines droplet-based single-cell RNA-seq with a strategy for barcoding CRISPR-mediated perturbations, allowing many perturbations to be profiled in pooled format. We applied Perturb-seq to dissect the mammalian unfolded protein response (UPR) using single and combinatorial CRISPR perturbations. Two genome-scale CRISPR interference (CRISPRi) screens identified genes whose repression perturbs ER homeostasis.

  9. 'Do you think you suffer from depression?' Reevaluating the use of a single item question for the screening of depression in older primary care patients

    DEFF Research Database (Denmark)

    Ayalon, Liat; Goldfracht, Margalit; Bech, Per

    2010-01-01

    evaluated against a depression diagnosis made by the Structured Clinical Interview for DSM-IV. RESULTS: Overall, 3.9% of the sample was diagnosed with depression. The most notable finding was that the single-item question, 'do you think you suffer from depression?' had as good or better sensitivity (83......%) than all other screens. Nonetheless, its specificity of 83% suggested that it has to be followed up by a through diagnostic interview. Additional sensitivity analyses concerning the use of a single depression item taken directly from the depression screening measures supported this finding. CONCLUSIONS......: An easy way to detect depression in older primary care patients would be asking the single question, 'do you think you suffer from depression?'...

  10. Label-free screening of single biomolecules through resistive pulse sensing technology for precision medicine applications

    Science.gov (United States)

    Harrer, S.; Kim, S. C.; Schieber, C.; Kannam, S.; Gunn, N.; Moore, S.; Scott, D.; Bathgate, R.; Skafidas, S.; Wagner, J. M.

    2015-05-01

    Employing integrated nano- and microfluidic circuits for detecting and characterizing biological compounds through resistive pulse sensing technology is a vibrant area of research at the interface of biotechnology and nanotechnology. Resistive pulse sensing platforms can be customized to study virtually any particle of choice which can be threaded through a fluidic channel and enable label-free single-particle interrogation with the primary read-out signal being an electric current fingerprint. The ability to perform label-free molecular screening with single-molecule and even single binding site resolution makes resistive pulse sensing technology a powerful tool for analyzing the smallest units of biological systems and how they interact with each other on a molecular level. This task is at the core of experimental systems biology and in particular ‘omics research which in combination with next-generation DNA-sequencing and next-generation drug discovery and design forms the foundation of a novel disruptive medical paradigm commonly referred to as personalized medicine or precision medicine. DNA-sequencing has approached the 1000-Dollar-Genome milestone allowing for decoding a complete human genome with unmatched speed and at low cost. Increased sequencing efficiency yields massive amounts of genomic data. Analyzing this data in combination with medical and biometric health data eventually enables understanding the pathways from individual genes to physiological functions. Access to this information triggers fundamental questions for doctors and patients alike: what are the chances of an outbreak for a specific disease? Can individual risks be managed and if so how? Which drugs are available and how should they be applied? Could a new drug be tailored to an individual’s genetic predisposition fast and in an affordable way? In order to provide answers and real-life value to patients, the rapid evolvement of novel computing approaches for analyzing big data in

  11. Label-free screening of single biomolecules through resistive pulse sensing technology for precision medicine applications.

    Science.gov (United States)

    Harrer, S; Kim, S C; Schieber, C; Kannam, S; Gunn, N; Moore, S; Scott, D; Bathgate, R; Skafidas, S; Wagner, J M

    2015-05-08

    Employing integrated nano- and microfluidic circuits for detecting and characterizing biological compounds through resistive pulse sensing technology is a vibrant area of research at the interface of biotechnology and nanotechnology. Resistive pulse sensing platforms can be customized to study virtually any particle of choice which can be threaded through a fluidic channel and enable label-free single-particle interrogation with the primary read-out signal being an electric current fingerprint. The ability to perform label-free molecular screening with single-molecule and even single binding site resolution makes resistive pulse sensing technology a powerful tool for analyzing the smallest units of biological systems and how they interact with each other on a molecular level. This task is at the core of experimental systems biology and in particular 'omics research which in combination with next-generation DNA-sequencing and next-generation drug discovery and design forms the foundation of a novel disruptive medical paradigm commonly referred to as personalized medicine or precision medicine. DNA-sequencing has approached the 1000-Dollar-Genome milestone allowing for decoding a complete human genome with unmatched speed and at low cost. Increased sequencing efficiency yields massive amounts of genomic data. Analyzing this data in combination with medical and biometric health data eventually enables understanding the pathways from individual genes to physiological functions. Access to this information triggers fundamental questions for doctors and patients alike: what are the chances of an outbreak for a specific disease? Can individual risks be managed and if so how? Which drugs are available and how should they be applied? Could a new drug be tailored to an individual's genetic predisposition fast and in an affordable way? In order to provide answers and real-life value to patients, the rapid evolvement of novel computing approaches for analyzing big data in

  12. Comparison of Alcohol Use Disorder Screens During College Athlete Pre-Participation Evaluations.

    Science.gov (United States)

    Majka, Erek; Graves, Travis; Diaz, Vanessa A; Player, Marty S; Dickerson, Lori M; Gavin, Jennifer K; Wessell, Andrea

    2016-05-01

    The US Preventive Services Task Force (USPSTF) recommends screening adults for alcohol misuse, a challenge among young adults who may not have regular primary care. The pre-participation evaluation (PPE) provides an opportunity for screening, but traditional screening tools require extra time in an already busy visit. The objective of this study was to compare the 10-item Alcohol Use Disorders Identification Test (AUDIT) with a single-question alcohol misuse screen in a population of college-aged athletes. This cross-sectional study was performed during an athletic PPE clinic at a college in the Southeastern United States among athletes ages 18 years and older. Written AUDIT and single-question screen "How many times in the past year have you had X or more drinks in a day?" (five for men, four for women) asked orally were administered to each participant. Sensitivity, specificity, and positive and negative predictive values for the single-question screen were compared to AUDIT. A total of 225 athletes were screened; 60% were female; 29% screened positive by AUDIT; 59% positive by single-question instrument. Males were more likely to screen positive by both methods. Compared to the AUDIT, the brief single-question screen had 92% sensitivity for alcohol misuse and 55% specificity. The negative predictive value of the single-question screen was 95% compared to AUDIT. A single-question screen for alcohol misuse in college-aged athletes had a high sensitivity and negative predictive value compared to the more extensive AUDIT screen. Ease of administration of this screening tool is ideal for use within the pre-participation physical among college-aged athletes who may not seek regular medical care.

  13. Cathode ray tube screens

    International Nuclear Information System (INIS)

    Cockayne, B.; Robbins, D.J.; Glasper, J.L.

    1982-01-01

    An improved cathode ray tube screen is described which consists of a single- or a poly-crystalline slice of a material such as yttrium aluminium garnet in which dopants such as Tb 3 + , Eu 3 + , Ce 3 + or Tm 3 + are ion implanted to different depths or in different areas of the screen. Annealing the screen removes lattice damage caused by the ion implanting and assists the diffusion of the dopant into the crystal. (U.K.)

  14. Comfortably engaging: which approach to alcohol screening should we use?

    Science.gov (United States)

    Vinson, Daniel C; Galliher, James M; Reidinger, Carol; Kappus, Jennifer A

    2004-01-01

    We wanted to compare 2 screening instruments for problem drinking, the CAGE and a single question, assessing frequency of use, patient and clinician comfort, and patient engagement in change. The study was a crossover, cluster-randomized clinical trial with 31 clinicians in Missouri and 13 in the American Academy of Family Physicians (AAFP) National Network for Family Practice and Primary Care Research; 2,800 patients provided data. The clinician was the unit of randomization. Clinicians decided whether to screen each patient; if they chose to screen, they used the screening approach assigned for that block of patients. The clinician and patient separately completed questionnaires immediately after the office visit to assess each one's comfort with screening (and any ensuing discussion) and the patient's engagement in change. Missouri clinicians screened more patients when assigned the single question (81%) than the CAGE (69%, P = .001 in weighted analysis). There was no difference among AAFP network clinicians (96% of patients screened with the CAGE, 97% with the single question). Eighty percent to 90% of clinicians and 70% of patients reported being comfortable with screening and the ensuing discussion, with no difference between approaches in either network. About one third of patients who were identified as problem drinkers reported thinking about or planning to change their drinking behavior, with no difference in engagement between screening approaches. Clinicians and patients reported similar comfort with the CAGE questions and the single-question screening tools for problem drinking, and the 2 instruments were equal in their ability to engage the patient. In Missouri, the single question was more likely to be used.

  15. Identification of tumor associated single-chain Fv by panning and screening antibody phage library using tumor cells

    Science.gov (United States)

    Nie, Yong-Zhan; He, Feng-Tian; Li, Zhi-Kui; Wu, Kai-Chun; Cao, Yun-Xin; Chen, Bao-Jun; Fan, Dai-Ming

    2002-01-01

    AIM: To study the feasibility of panning and screening phage-displaying recombinant single-chain variable fragment (ScFv) of anti-tumor monoclonal antibodies for fixed whole cells as the carriers of mAb-binding antigens. METHODS: The recombinant phage displaying libraries for anti-colorectal tumor mAb MC3Ab, MC5Ab and anti-gastric tumor mAb MGD1 was constructed. Panning and screening were carried out by means of modified fixation of colorectal and gastric tumor cells expressed the mAb-binding antigens. Concordance of binding specificity to tumor cells between phage clones and parent antibodies was analyzed. The phage of positive clones was identified with competitive ELISA, and infected by E. coli HB2151 to express soluble ScFv. RESULTS: The ratio of positive clones to MC3-ScF-MC5-ScFv and MGD1-ScFv were 60%, 24% and 30%. MC3-ScFv had Mr 32000 confirmed by Western blot. The specificity to antigen had no difference between 4 positive recombinant phage antibodies and MC3Ab. CONCLUSION: The modified process of fixing whole tumor cells is efficient, convenient and feasible to pan and screen the phage-displaying ScFv of anti-tumor monoclonal antibodies. PMID:12174367

  16. Diagnostic dilemma of the single screening test used in the diagnosis of syphilis in Nepal.

    Science.gov (United States)

    Dumre, S P; Shakya, G; Acharya, D; Malla, S; Adhikari, N

    2011-12-01

    Syphilis screening by the nontreponemal rapid plasma reagin (RPR) test is not usually followed up by specific treponemal tests in most of the resource poor healthcare settings of Nepal. We analyzed serum specimens of 504 suspected syphilis cases at the immunology department of the national reference laboratory in Nepal during 2007-2009 using RPR test and Treponema pallidum hemagglutination assay (TPHA). In overall, 35.7% were positive by both methods (combination) while 13.1% were RPR positive and TPHA negative, 8.7% were positive by TPHA only and 42.5% were negative by both methods. Among the RPR reactive (n = 246), 73.2% were positive by TPHA. Non-specific agglutination in RPR testing was relatively higher (26.8%) compared to TPHA (19.6%). Although TPHA was found more specific than RPR test, either of the single tests produced inaccurate diagnosis. Since the single RPR testing for syphilis may yield false positive results, specific treponemal test should be routinely used as confirmatory test to rule out false RPR positive cases. More attention needs to be paid on formulation of strict policy on the implementation of the existing guidelines throughout the country to prevent misdiagnosis in syphilis with the use of single RPR test.

  17. Evaluation of a single-item screening question to detect limited health literacy in peritoneal dialysis patients.

    Science.gov (United States)

    Jain, Deepika; Sheth, Heena; Bender, Filitsa H; Weisbord, Steven D; Green, Jamie A

    2014-01-01

    Studies have shown that a single-item question might be useful in identifying patients with limited health literacy. However, the utility of the approach has not been studied in patients receiving maintenance peritoneal dialysis (PD). We assessed health literacy in a cohort of 31 PD patients by administering the Rapid Estimate of Adult Literacy in Medicine (REALM) and a single-item health literacy (SHL) screening question "How confident are you filling out medical forms by yourself?" (Extremely, Quite a bit, Somewhat, A little bit, or Not at all). To determine the accuracy of the single-item question for detecting limited health literacy, we performed sensitivity and specificity analyses of the SHL and plotted the area under the receiver operating characteristic (AUROC) curve using the REALM as a reference standard. Using a cut-off of "Somewhat" or less confident, the sensitivity of the SHL for detecting limited health literacy was 80%, and the specificity was 88%. The positive likelihood ratio was 6.9. The SHL had an AUROC of 0.79 (95% confidence interval: 0.52 to 1.00). Our results show that the SHL could be effective in detecting limited health literacy in PD patients.

  18. Single Health System Adherence to 2012 Cervical Cancer Screening Guidelines at Extremes of Age and Posthysterectomy.

    Science.gov (United States)

    Teoh, Deanna; Isaksson Vogel, Rachel; Hultman, Gretchen; Monu, Minnu; Downs, Levi; Geller, Melissa A; Le, Chap; Melton-Meaux, Genevieve; Kulasingam, Shalini

    2017-03-01

    To estimate the proportion of guideline nonadherent Pap tests in women aged younger than 21 years and older than 65 years and posthysterectomy in a single large health system. Secondary objectives were to describe temporal trends and patient and health care provider characteristics associated with screening in these groups. A retrospective cross-sectional chart review was performed at Fairview Health Services and University of Minnesota Physicians. Reasons for testing and patient and health care provider information were collected. Tests were designated as indicated or nonindicated per the 2012 cervical cancer screening guidelines. Point estimates and descriptive statistics were calculated. Patient and health care provider characteristics were compared between indicated and nonindicated groups using χ and Wilcoxon rank-sum tests. A total of 3,920 Pap tests were performed between September 9, 2012, and August 31, 2014. A total of 257 (51%; 95% confidence interval [CI] 46.1-54.9%) of tests in the younger than 21 years group, 536 (40%; 95% CI 37.7-43.1%) in the older than 65 years group, and 605 (29%; 95% CI 27.1-31.0%) in the posthysterectomy group were not indicated. White race in the older than 65 years group was the only patient characteristic associated with receipt of a nonindicated Pap test (P=.007). Health care provider characteristics associated with nonindicated Pap tests varied by screening group. Temporal trends showed a decrease in the proportion of nonindicated tests in the younger than 21 years group but an increase in the posthysterectomy group. For women aged younger than 21 years and older than 65 years and posthysterectomy, 35% of Pap tests performed in our health system were not guideline-adherent. There were no patient or health care provider characteristics associated with guideline nonadherent screening across all groups.

  19. Cervical cancer screening: Safety, acceptability, and feasibility of a single-visit approach in Bulawayo, Zimbabwe.

    Science.gov (United States)

    Fallala, Muriel S; Mash, Robert

    2015-05-05

    Cervical cancer is the commonest cancer amongst African women, and yet preventative services are often inadequate. The purpose of the study was to assess the safety, acceptability and feasibility of visual inspection with acetic acid and cervicography (VIAC) followed by cryotherapy or a loop electrical excision procedure (LEEP) at a single visit for prevention of cancer of the cervix. The United Bulawayo Hospital, Zimbabwe. The study was descriptive, using retrospective data extracted from electronic medical records of women attending the VIAC clinic. Over 24 months 4641 women visited the clinic and were screened for cervical cancer using VIAC. Cryotherapy or LEEP was offered immediately to those that screened positive. Treated women were followed up at three months and one year. The rate of positive results on VIAC testing was 10.8%. Of those who were eligible, 17.0% received immediate cryotherapy, 44.1% received immediate LEEP, 1.9% delayed treatment, and 37.0% were referred to a gynaecologist. No major complications were recorded after cryotherapy or LEEP. Amongst those treated 99.5% expressed satisfaction with their experience. Only 3.2% of those treated at the clinic had a positive result on VIAC one year later. The service was shown to be feasible to sustain over time with the necessary consumables. There were no service-related treatment postponements and the clinic staff and facility were able to meet the demand for the service. A single-visit approach using VIAC, followed by cryotherapy or LEEP, proved to be safe, acceptable and feasible in an urban African setting in Bulawayo, Zimbabwe. Outcomes a year later suggested that treatment had been effective.

  20. Photon attenuation by intensifying screens

    International Nuclear Information System (INIS)

    Holje, G.

    1983-01-01

    The photon attenuation by intensifying screens of different chemical composition has been determined. The attenuation of photons between 20 keV and 120 keV was measured by use of a multi-channel analyzer and a broad bremsstrahlung distribution. The attenuation by the intensifying screens was hereby determined simultaneously at many different monoenergetic photon energies. Experimentally determined attenuations were found to agree well with attenuation calculated from mass attenuation coefficients. The attenuation by the screens was also determined at various bremsstrahlung distributions, simulating those occurring behind the patient in various diagnostic X-ray examinations. The high attenuation in some of the intensifying screens form the basis for an analysis of the construction of asymmetric screen pairs. Single screen systems are suggested as a favourable alternative to thick screen pair systems. (Author)

  1. Adverse selection without single crossing

    DEFF Research Database (Denmark)

    Schottmüller, Christoph

    2015-01-01

    The single-crossing assumption simplifies the analysis of screening models as local incentive compatibility becomes sufficient for global incentive compatibility. If single crossing is violated, global incentive compatibility constraints have to be taken into account. This paper studies monotone...... solutions in a screening model that allows a one-time violation of single crossing. The results show that local and non-local incentive constraints distort the solution in opposite directions. Therefore, the optimal decision might involve distortions above as well as below the first-best decision...

  2. Tarsal taste neuron activity and proboscis extension reflex in response to sugars and amino acids in Helicoverpa armigera (Hubner).

    Science.gov (United States)

    Zhang, Yun-Feng; van Loon, Joop J A; Wang, Chen-Zhu

    2010-08-15

    In adult female Helicoverpa armigera (Hübner), the fifth tarsomere of the prothoracic legs bears 14 gustatory trichoid chemosensilla. These chemosensilla were characterized through electrophysiological experiments by stimulating with sucrose, glucose, fructose, maltose, myo-inositol and 20 common amino acids. In electrophysiological recordings from nine sensilla, responses were obtained to certain compounds tested at 100 mmol l(-1), and the response spectra differed from broad to narrow. The four sugars excited the same receptor neuron in sensillum a and sensillum b; sucrose and myo-inositol, sucrose and lysine, myo-inositol and lysine excited two different receptor neurons respectively in sensillum a; fructose and lysine excited two different receptor neurons in sensillum n. Furthermore, the four sugars, myo-inositol and lysine all elicited concentration-dependent electrophysiological responses. These six compounds also induced the proboscis extension reflex (PER) followed by ingestion of the solution when they were applied on the tarsi. Lysine and sucrose caused the strongest electrophysiological responses. However, sucrose had the strongest stimulatory effect on the PER whereas lysine had the weakest. Mixtures of sucrose with the other sugars or with lysine had a similar stimulatory effect on the PER as sucrose alone. The electrophysiological and behavioural responses caused by a range of sucrose concentrations were positively correlated. We conclude that the tarsal gustatory sensilla play an essential role in perceiving sugars available in floral nectar and provide chemosensory information determining feeding behaviour. Tarsal taste-receptor-neuron responses to lysine are implicated in oviposition behaviour.

  3. Intra-observer agreement in single and joint double readings of contrast-enhanced breast MRI screening for women with high genetic breast cancer risks

    Directory of Open Access Journals (Sweden)

    Hugo C

    2013-04-01

    Full Text Available Objectives: To examine intra-observer reliability (IR for lesion detection on contrast-enhanced breast magnetic resonance images (MRI for screening women at high risk of breast cancer in single and joint double readings, without case selection. Methods: Contrast-enhanced breast MRIs were interpreted twice by the same independent reader and twice in joint readings. IR was assessed for lesion detection, normal MRI identification, mass, non-mass like enhancements (NMLE and focus characterisation, and BI-RADS assessment. Results: MRI examinations for 124 breasts, 65 women (mean age 43.4y were retrospectively reviewed with 110 lesions identified. Abnormal BIRADS (3-5 classifications were found for 52.3% in single readings and 58.5% in joint readings. Seven biopsies were performed for 4 histologically confirmed cancers. IR for BI-RADS classifications was good for single (0.63, 95% CI: 0.49-0.77, and joint readings (0.77, 95% CI: 0.61-0.93. IR for background parenchymal enhancement (BPE was moderate across single (0.53, 95% CI: 0.40-0.65 and joint readings (0.44, 95% CI: 0.33-0.56. IR for BI-RADS category according to each enhancement was poor for single (0.27, 95% CI: 0.10-0.44, and higher for joint readings, (0.58, 95% CI: 0.43-0.72. Conclusions: IR in BI-RADS breast assessments or BI-RADS lesion assessments are better with joint reading in screening for women with high genetic risks, in particular for abnormal MRI (BI-RADS 3, 4 and 5.

  4. Introduction of the colorectal cancer screening program: results from a single centre study.

    Science.gov (United States)

    Vermeer, Nina C A; Bahadoer, Renu R; Bastiaannet, Esther; Holman, Fabian A; Meershoek-Klein Kranenbarg, Elma; Liefers, Gerrit-Jan; van de Velde, Cornelis J H; Peeters, Koen C M J

    2018-06-19

    In 2014, a national colorectal cancer (CRC) screening program was launched in the Netherlands. It is difficult to assess for the individual CRC patient whether the oncological benefits of surgery will outweigh the morbidity of the procedure, especially in early lesions. This study compares patient and tumour characteristics between screen-detected and non-screen-detected patients. Secondly, we present an overview of treatment options and clinical dilemmas when treating patients with early stage colorectal disease. Between January 2014 and December 2016, all patients with non-malignant polyps or CRC who were referred to the Department of Surgery of the Leiden University Medical Centre in the Netherlands were included. Baseline characteristics, type of treatment and short-term outcomes of patients with screen-detected and non-screen-detected colorectal tumours were compared. A total of 426 patients were included, of whom 240 (56.3%) were identified by screening. Non-screen-detected patients more often had comorbidity (p=0.03), the primary tumour was more often located in the rectum (p=0.001) and there was a higher rate of metastatic disease (p<0.001). Among 354 surgically treated patients, postoperative adverse events did not significantly differ between the two groups (p=0.38). Of 46 patients with T1 CRC in the endoscopic resection specimen, 23 underwent surgical resection of which only 30.4% had residual invasive disease at colectomy. Despite differences in comorbidity and stage, surgical outcome of patients with screen-detected tumours compared to non-screen-detected tumours was not significantly different. Considering its limited oncological benefits as well as the rate of adverse events, surgery for non-malignant polyps and T1 CRC should be considered carefully. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  5. Subchronic immunotoxicity and screening of reproductive toxicity and developmental immunotoxicity following single instillation of HIPCO-single-walled carbon nanotubes: purity-based comparison.

    Science.gov (United States)

    Park, Eun-Jung; Choi, Je; Kim, Jae-Ho; Lee, Byoung-Seok; Yoon, Cheolho; Jeong, Uiseok; Kim, Younghun

    2016-10-01

    Impurity has been suggested as an important factor determining toxicity following exposure to single-walled carbon nanotubes (SWCNTs). In this study, we first compared immunotoxicity based on iron content on day 90 after a single intratracheal instillation of SWCNTs in male and female mice. The inflammatory responses were generally stronger in mice exposed to acid-purified (P)-SWCNTs compared to raw (R)-SWCNTs. In addition, both R- and P-SWCNTs induced Th1-polarized immune responses with apoptotic death of BAL cells and systemically impaired the function of antigen-presenting cells (APC). We also screened reproductive and developmental toxicity by cohabitating male and female mice on day 14 after instillation. Interestingly, the pregnancy rate rapidly decreased following exposure to both types of SWCNTs, especially R-SWCNTs. In addition, we investigated developmental immunotoxicity of the offspring on day 28 after exposure to both types of SWCNTs. Their hematological changes were clearer relative to those of the parents and a significant decrease in the alkaline phosphatase and potassium levels was observed in mice of both sexes exposed to the higher dose of R- and P-SWCNTs. In conclusion, we suggest that SWCNTs may induce Th1-polarized immune responses accompanied by suppression of APC function on day 90 after a single instillation without significant iron content dependance. In addition, the consecutive exposure of SWCNTs to the subsequent generation may exacerbate metabolic and hematological disturbance. Furthermore, our results underscore the need to clarify the reproductive and developmental health effects of SWCNTs.

  6. The benefits of cancer screening in kidney transplant recipients: a single-center experience.

    Science.gov (United States)

    Kato, Taigo; Kakuta, Yoichi; Abe, Toyofumi; Yamanaka, Kazuaki; Imamura, Ryoichi; Okumi, Masayoshi; Ichimaru, Naotsugu; Takahara, Shiro; Nonomura, Norio

    2016-02-01

    The frequency of malignancy is increasing in kidney transplant recipients. Posttransplant malignancy (PTM) is a major cause of long-term graft survival inhibition. In this study, we evaluated the frequency and prognosis of PTM at our center and examined the efficacy of cancer screening. Between 1972 and 2013, 750 patients were followed-up at our center. Annual physical examinations and screenings were performed to detect PTM. We investigated the detail of two distinctive cancer groups: screening-detected cancers and symptom-detected cancers. Seventy-seven PTM were identified during the follow-up period. The mean age at the initial PTM detection was 43.6 ± 12.8 years. The mean interval from transplantation to cancer diagnosis was 134.5 ± 11.3 months. Among the 77 patients, posttransplant lymphoproliferative disease (PTLD) was the most common cancer (19.5%, 15/77), followed by renal cell carcinoma (15.6%, 12/77). Of the cancer cases, 46.8% (36/77) were detected via screening. The most frequently screening-detected cancer was renal cell carcinoma of the native kidney and breast cancer (22.2%, 8/36). However, it was difficult to detect PTLD, urothelial carcinoma, and colorectal cancer via screening. Interestingly, Cox proportional regression analyses revealed nonscreened recipients to be a significant prognostic factor for PTM (P kidney transplant recipients. These findings support the provision of long-term appropriate screening for kidney transplant recipients. © 2015 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  7. Single-item measures for depression and anxiety: Validation of the Screening Tool for Psychological Distress in an inpatient cardiology setting.

    Science.gov (United States)

    Young, Quincy-Robyn; Nguyen, Michelle; Roth, Susan; Broadberry, Ann; Mackay, Martha H

    2015-12-01

    Depression and anxiety are common among patients with cardiovascular disease (CVD) and confer significant cardiac risk, contributing to CVD morbidity and mortality. Unfortunately, due to the lack of screening tools that address the specific needs of hospitalized patients, few cardiac inpatient programs offer routine screening for these forms of psychological distress, despite recommendations to do so. The purpose of this study was to validate single-item measures for depression and anxiety among cardiac inpatients. Consecutive inpatients were recruited from the cardiology and cardiac surgery step-down units at a university-affiliated, quaternary-care hospital. Subjects completed a questionnaire that included: (a) demographics, (b) single-item-measures for depression and anxiety (from the Screening Tool for Psychological Distress (STOP-D)), and (c) Hospital Anxiety and Depression Scale (HADS). One hundred and five participants were recruited with a wide variety of cardiac diagnoses, having a mean age of 66 years, and 28% were women. Both STOP-D items were highly correlated with their corresponding validated measures and demonstrated robust receiver-operator characteristic curves. Severity scores on both items correlated well with established severity cut-off scores on the corresponding subscales of the HADS. The STOP-D is a self-administered, self-report measure using two independent items that provide severity scores for depression and anxiety. The tool performs very well compared with other previously validated measures. Requiring no additional scoring and being free, STOP-D offers a simple and valid method for identifying hospitalized cardiac patients who are experiencing psychological distress. This crucial first step triggers initiation of appropriate monitoring and intervention, thus reducing the likelihood of the adverse cardiac outcomes associated with psychological distress. © The European Society of Cardiology 2014.

  8. X-ray screening materials

    International Nuclear Information System (INIS)

    Wardley, R.B.

    1981-01-01

    This invention relates to x-ray screening materials and especially to materials in sheet form for use in the production of, for example, protective clothing such as aprons and lower back shields, curtains, mobile screens and suspended shields. The invention is based on the observation that x-ray screening materials in sheet form having greater flexiblity than the hitherto known x-ray screening materials of the same x-ray absorber content can be produced if, instead of using a single sheet of filled sheet material of increased thickness, one uses a plurality of sheets of lesser thickness together forming a laminar material of the desired thickness and one bonds the individual sheets together at their edges and, optionally, at other spaced apart points away from the edges thereby allowing one sheet to move relative to another. (U.K.)

  9. RNAi High-Throughput Screening of Single- and Multi-Cell-Type Tumor Spheroids: A Comprehensive Analysis in Two and Three Dimensions.

    Science.gov (United States)

    Fu, Jiaqi; Fernandez, Daniel; Ferrer, Marc; Titus, Steven A; Buehler, Eugen; Lal-Nag, Madhu A

    2017-06-01

    The widespread use of two-dimensional (2D) monolayer cultures for high-throughput screening (HTS) to identify targets in drug discovery has led to attrition in the number of drug targets being validated. Solid tumors are complex, aberrantly growing microenvironments that harness structural components from stroma, nutrients fed through vasculature, and immunosuppressive factors. Increasing evidence of stromally-derived signaling broadens the complexity of our understanding of the tumor microenvironment while stressing the importance of developing better models that reflect these interactions. Three-dimensional (3D) models may be more sensitive to certain gene-silencing events than 2D models because of their components of hypoxia, nutrient gradients, and increased dependence on cell-cell interactions and therefore are more representative of in vivo interactions. Colorectal cancer (CRC) and breast cancer (BC) models composed of epithelial cells only, deemed single-cell-type tumor spheroids (SCTS) and multi-cell-type tumor spheroids (MCTS), containing fibroblasts were developed for RNAi HTS in 384-well microplates with flat-bottom wells for 2D screening and round-bottom, ultra-low-attachment wells for 3D screening. We describe the development of a high-throughput assay platform that can assess physiologically relevant phenotypic differences between screening 2D versus 3D SCTS, 3D SCTS, and MCTS in the context of different cancer subtypes. This assay platform represents a paradigm shift in how we approach drug discovery that can reduce the attrition rate of drugs that enter the clinic.

  10. A Novel Affinity Tag, ABTAG, and Its Application to the Affinity Screening of Single-Domain Antibodies Selected by Phage Display

    Directory of Open Access Journals (Sweden)

    Greg Hussack

    2017-10-01

    Full Text Available ABTAG is a camelid single-domain antibody (sdAb that binds to bovine serum albumin (BSA with low picomolar affinity. In surface plasmon resonance (SPR analyses using BSA surfaces, bound ABTAG can be completely dissociated from the BSA surfaces at low pH, over multiple cycles, without any reduction in the capacity of the BSA surfaces to bind ABTAG. A moderate throughput, SPR-based, antibody screening assay exploiting the unique features of ABTAG is described. Anti-carcinoembryonic antigen-related cell adhesion molecule 6 (CEACAM6 sdAbs were isolated from a phage-displayed sdAb library derived from the heavy chain antibody repertoire of a llama immunized with CEACAM6. Following one or two rounds of panning, enriched clones were expressed as ABTAG fusions in microtiter plate cultures. The sdAb-ABTAG fusions from culture supernatants were captured on BSA surfaces and CEACAM6 antigen was then bound to the captured molecules. The SPR screening method gives a read-out of relative expression levels of the fusion proteins and kinetic and affinity constants for CEACAM6 binding by the captured molecules. The library was also panned and screened by conventional methods and positive clones were subcloned and expressed for SPR analysis. Compared to conventional panning and screening, the SPR-based ABTAG method yielded a considerably higher diversity of binders, some with affinities that were three orders of magnitude higher affinity than those identified by conventional panning.

  11. Laboratory Screening for Children Entering Foster Care.

    Science.gov (United States)

    Greiner, Mary V; Beal, Sarah J; Nause, Katie; Staat, Mary Allen; Dexheimer, Judith W; Scribano, Philip V

    2017-12-01

    To determine the prevalence of medical illness detected by laboratory screening in children entering foster care in a single, urban county. All children entering foster care in a single county in Ohio were seen at a consultation foster care clinic and had laboratory screening, including testing for infectious diseases such as HIV, hepatitis B, hepatitis C, syphilis, and tuberculosis as well as for hemoglobin and lead levels. Over a 3-year period (2012-2015), laboratory screening was performed on 1977 subjects entering foster care in a consultative foster care clinic. The prevalence of hepatitis B, hepatitis C, syphilis, and tuberculosis were all found to be <1%. There were no cases of HIV. Seven percent of teenagers entering foster care tested positive for Chlamydia . A secondary finding was that 54% of subjects were hepatitis B surface antibody-negative, indicating an absence of detected immunity to the hepatitis B virus. Routine laboratory screening for children entering foster care resulted in a low yield. Targeted, rather than routine, laboratory screening may be a more clinically meaningful approach for children entering foster care. Copyright © 2017 by the American Academy of Pediatrics.

  12. Prenatal Screening Using Maternal Markers

    Directory of Open Access Journals (Sweden)

    Howard Cuckle

    2014-05-01

    Full Text Available Maternal markers are widely used to screen for fetal neural tube defects (NTDs, chromosomal abnormalities and cardiac defects. Some are beginning to broaden prenatal screening to include pregnancy complications such as pre-eclampsia. The methods initially developed for NTDs using a single marker have since been built upon to develop high performance multi-maker tests for chromosomal abnormalities. Although cell-free DNA testing is still too expensive to be considered for routine application in public health settings, it can be cost-effective when used in combination with existing multi-maker marker tests. The established screening methods can be readily applied in the first trimester to identify pregnancies at high risk of pre-eclampsia and offer prevention though aspirin treatment. Prenatal screening for fragile X syndrome might be adopted more widely if the test was to be framed as a form of maternal marker screening.

  13. A broad phenotypic screen identifies novel phenotypes driven by a single mutant allele in Huntington's disease CAG knock-in mice.

    Directory of Open Access Journals (Sweden)

    Sabine M Hölter

    Full Text Available Huntington's disease (HD is an autosomal dominant neurodegenerative disorder caused by the expansion of a CAG trinucleotide repeat in the HTT gene encoding huntingtin. The disease has an insidious course, typically progressing over 10-15 years until death. Currently there is no effective disease-modifying therapy. To better understand the HD pathogenic process we have developed genetic HTT CAG knock-in mouse models that accurately recapitulate the HD mutation in man. Here, we describe results of a broad, standardized phenotypic screen in 10-46 week old heterozygous HdhQ111 knock-in mice, probing a wide range of physiological systems. The results of this screen revealed a number of behavioral abnormalities in HdhQ111/+ mice that include hypoactivity, decreased anxiety, motor learning and coordination deficits, and impaired olfactory discrimination. The screen also provided evidence supporting subtle cardiovascular, lung, and plasma metabolite alterations. Importantly, our results reveal that a single mutant HTT allele in the mouse is sufficient to elicit multiple phenotypic abnormalities, consistent with a dominant disease process in patients. These data provide a starting point for further investigation of several organ systems in HD, for the dissection of underlying pathogenic mechanisms and for the identification of reliable phenotypic endpoints for therapeutic testing.

  14. Tiered High-Throughput Screening Approach to Identify ...

    Science.gov (United States)

    High-throughput screening (HTS) for potential thyroid–disrupting chemicals requires a system of assays to capture multiple molecular-initiating events (MIEs) that converge on perturbed thyroid hormone (TH) homeostasis. Screening for MIEs specific to TH-disrupting pathways is limited in the US EPA ToxCast screening assay portfolio. To fill one critical screening gap, the Amplex UltraRed-thyroperoxidase (AUR-TPO) assay was developed to identify chemicals that inhibit TPO, as decreased TPO activity reduces TH synthesis. The ToxCast Phase I and II chemical libraries, comprised of 1,074 unique chemicals, were initially screened using a single, high concentration to identify potential TPO inhibitors. Chemicals positive in the single concentration screen were retested in concentration-response. Due to high false positive rates typically observed with loss-of-signal assays such as AUR-TPO, we also employed two additional assays in parallel to identify possible sources of nonspecific assay signal loss, enabling stratification of roughly 300 putative TPO inhibitors based upon selective AUR-TPO activity. A cell-free luciferase inhibition assay was used to identify nonspecific enzyme inhibition among the putative TPO inhibitors, and a cytotoxicity assay using a human cell line was used to estimate the cellular tolerance limit. Additionally, the TPO inhibition activities of 150 chemicals were compared between the AUR-TPO and an orthogonal peroxidase oxidation assay using

  15. Development and validation of concurrent preimplantation genetic diagnosis for single gene disorders and comprehensive chromosomal aneuploidy screening without whole genome amplification.

    Science.gov (United States)

    Zimmerman, Rebekah S; Jalas, Chaim; Tao, Xin; Fedick, Anastasia M; Kim, Julia G; Pepe, Russell J; Northrop, Lesley E; Scott, Richard T; Treff, Nathan R

    2016-02-01

    To develop a novel and robust protocol for multifactorial preimplantation genetic testing of trophectoderm biopsies using quantitative polymerase chain reaction (qPCR). Prospective and blinded. Not applicable. Couples indicated for preimplantation genetic diagnosis (PGD). None. Allele dropout (ADO) and failed amplification rate, genotyping consistency, chromosome screening success rate, and clinical outcomes of qPCR-based screening. The ADO frequency on a single cell from a fibroblast cell line was 1.64% (18/1,096). When two or more cells were tested, the ADO frequency dropped to 0.02% (1/4,426). The rate of amplification failure was 1.38% (55/4,000) overall, with 2.5% (20/800) for single cells and 1.09% (35/3,200) for samples that had two or more cells. Among 152 embryos tested in 17 cases by qPCR-based PGD and CCS, 100% were successfully given a diagnosis, with 0% ADO or amplification failure. Genotyping consistency with reference laboratory results was >99%. Another 304 embryos from 43 cases were included in the clinical application of qPCR-based PGD and CCS, for which 99.7% (303/304) of the embryos were given a definitive diagnosis, with only 0.3% (1/304) having an inconclusive result owing to recombination. In patients receiving a transfer with follow-up, the pregnancy rate was 82% (27/33). This study demonstrates that the use of qPCR for PGD testing delivers consistent and more reliable results than existing methods and that single gene disorder PGD can be run concurrently with CCS without the need for additional embryo biopsy or whole genome amplification. Copyright © 2016 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  16. The classification of normal screening mammograms

    Science.gov (United States)

    Ang, Zoey Z. Y.; Rawashdeh, Mohammad A.; Heard, Robert; Brennan, Patrick C.; Lee, Warwick; Lewis, Sarah J.

    2016-03-01

    Rationale and objectives: To understand how breast screen readers classify the difficulty of normal screening mammograms using common lexicon describing normal appearances. Cases were also assessed on their suitability for a single reader strategy. Materials and Methods: 15 breast readers were asked to interpret a test set of 29 normal screening mammogram cases and classify them by rating the difficulty of the case on a five-point Likert scale, identifying the salient features and assessing their suitability for single reading. Using the False Positive Fractions from a previous study, the 29 cases were classified into 10 "low", 10 "medium" and nine "high" difficulties. Data was analyzed with descriptive statistics. Spearman's correlation was used to test the strength of association between the difficulty of the cases and the readers' recommendation for single reading strategy. Results: The ratings from readers in this study corresponded to the known difficulty level of cases for the 'low' and 'high' difficulty cases. Uniform ductal pattern and density, symmetrical mammographic features and the absence of micro-calcifications were the main reasons associated with 'low' difficulty cases. The 'high' difficulty cases were described as having `dense breasts'. There was a statistically significant negative correlation between the difficulty of the cases and readers' recommendation for single reading (r = -0.475, P = 0.009). Conclusion: The findings demonstrated potential relationships between certain mammographic features and the difficulty for readers to classify mammograms as 'normal'. The standard Australian practice of double reading was deemed more suitable for most cases. There was an inverse moderate association between the difficulty of the cases and the recommendations for single reading.

  17. A comparative study of breast cancer mass screening using ultrasonography and mammography at a single institution

    International Nuclear Information System (INIS)

    Uemura, Tsuguo; Takahashi, Naohiko; Ueda, Kuniaki

    2011-01-01

    In order to evaluate the effectiveness of ultrasonic screening for breast cancer (US group) in comparison with mammographic screening (MMG group), we analyzed 78,214 breast screening examinees presenting between 2007 and 2008 at our institution. The cancer detection rate in the US group was lower than that in the MMG group. However, the average age in the US group was significantly younger than that in the MMG group, and the rate of annual screening was significantly higher in the former than in the latter. In the US subgroup who underwent annual screening, the recall rate and the cancer detection rate were significantly lower, and the rate of detection of early breast cancers was significantly higher than that in the subgroup who underwent screening biennially or at longer intervals, and there was no significant inter-group difference in the cancer detection rate between women in their 40s and those aged 50 or above who underwent annual screening. The proportion of early breast cancers detected was almost the same in the both groups. In summary, US screening as well as MMG screening seems to be useful for detection of early breast cancer. Although a high recall rate for US screening has been reported previously, annual screening and sufficient quality control based on the guidelines proposed by the Japan Association of Breast and Thyroid Sonology (JABTS) are considered to reduce the recall rate. (author)

  18. Helical CT for secondary screening of lung cancer

    International Nuclear Information System (INIS)

    Mori, Kiyoshi; Onishi, Tsukasa; Tominaga, Keigo; Kishiro, Izumi; Yokoyama, Kohki.

    1995-01-01

    Helical CT was used on a trial basis for secondary screening of lung cancer, and its clinical usefulness is discussed in this report. The subjects of 157 patients with abnormal shadows on plain chest X-ray images were chosen between November 1993 and August 1994. Imaging parameters used for screening CT were as follows: 50 mA, 120 kV, a couch-top movement speed of 20 mm/s, and a beam width of 10 mm. The entire lung field was scanned during a single breath-hold. Reconstructed images were generated at 10-mm intervals by the 180deg interpolation method, and films were produced. Images of the entire lung field were made during a single breath-hold in all patients. Abnormal shadows were detected in 73 of 157 patients by screening CT. These 73 patients included 14 with lung cancer, 53 with benign lesions, one under observation, and five others. The average diameter of the tumors was 11.1 mm. The lung cancers detected all arose in the periphery, and were classified into stage I (10 patients), stage IIIA (3 patients), and stage IV with bone metastases (1 patient). Lung cancers in clinical stage I (3 patients) and stage IV (1 patient) were difficult to see on plain chest X-ray films. We conclude that screening CT is useful for early diagnosis of lung cancer because the entire lung field can be imaged during a single breath-hold. Therefore, helical CT can be expected to be useful in screening for lung cancer. (author)

  19. SEMIAUTOMATED SOLID-PHASE EXTRACTION PROCEDURE FOR DRUG SCREENING IN BIOLOGICAL-FLUIDS USING THE ASPEC SYSTEM IN COMBINATION WITH CLEAN SCREEN DAU COLUMNS

    NARCIS (Netherlands)

    CHEN, XH; FRANKE, JP; ENSING, K; WIJSBEEK, J; DEZEEUW, RA

    1993-01-01

    The use of a semi-automated solid-phase extraction system (ASPEC) for the screening of drugs in plasma and urine on a single mixed-mode column (Clean Screen DAU) is described. The processes of column preconditioning, sample application, column wash, pH adjustment and elution of the drugs were

  20. Microchip screening platform for single cell assessment of NK cell cytotoxicity

    Directory of Open Access Journals (Sweden)

    Karolin eGuldevall

    2016-04-01

    Full Text Available Here we report a screening platform for assessment of the cytotoxic potential of individual natural killer (NK cells within larger populations. Human primary NK cells were distributed across a silicon-glass microchip containing 32 400 individual microwells loaded with target cells. Through fluorescence screening and automated image analysis the numbers of NK and live or dead target cells in each well could be assessed at different time points after initial mixing. Cytotoxicity was also studied by time-lapse live-cell imaging in microwells quantifying the killing potential of individual NK cells. Although most resting NK cells (≈75% were non-cytotoxic against the leukemia cell line K562, some NK cells were able to kill several (≥3 target cells within the 12 hours long experiment. In addition, the screening approach was adapted to increase the chance to find and evaluate serial killing NK cells. Even if the cytotoxic potential varied between donors it was evident that a small fraction of highly cytotoxic NK cells were responsible for a substantial portion of the killing. We demonstrate multiple assays where our platform can be used to enumerate and characterize cytotoxic cells, such as NK or T cells. This approach could find use in clinical applications, e.g. in the selection of donors for stem cell transplantation or generation of highly specific and cytotoxic cells for adoptive immunotherapy.

  1. Microchip Screening Platform for Single Cell Assessment of NK Cell Cytotoxicity

    Science.gov (United States)

    Guldevall, Karolin; Brandt, Ludwig; Forslund, Elin; Olofsson, Karl; Frisk, Thomas W.; Olofsson, Per E.; Gustafsson, Karin; Manneberg, Otto; Vanherberghen, Bruno; Brismar, Hjalmar; Kärre, Klas; Uhlin, Michael; Önfelt, Björn

    2016-01-01

    Here, we report a screening platform for assessment of the cytotoxic potential of individual natural killer (NK) cells within larger populations. Human primary NK cells were distributed across a silicon–glass microchip containing 32,400 individual microwells loaded with target cells. Through fluorescence screening and automated image analysis, the numbers of NK and live or dead target cells in each well could be assessed at different time points after initial mixing. Cytotoxicity was also studied by time-lapse live-cell imaging in microwells quantifying the killing potential of individual NK cells. Although most resting NK cells (≈75%) were non-cytotoxic against the leukemia cell line K562, some NK cells were able to kill several (≥3) target cells within the 12-h long experiment. In addition, the screening approach was adapted to increase the chance to find and evaluate serial killing NK cells. Even if the cytotoxic potential varied between donors, it was evident that a small fraction of highly cytotoxic NK cells were responsible for a substantial portion of the killing. We demonstrate multiple assays where our platform can be used to enumerate and characterize cytotoxic cells, such as NK or T cells. This approach could find use in clinical applications, e.g., in the selection of donors for stem cell transplantation or generation of highly specific and cytotoxic cells for adoptive immunotherapy. PMID:27092139

  2. Can the NHS breast screening programme afford not to double read screening mammograms?

    International Nuclear Information System (INIS)

    Liston, J.C.; Dall, B.J.G.

    2003-01-01

    AIM: Rapid expansion of the National Health Service (UK) Breast Screening Programme (NHSBSP) to routinely invite women aged 50-70 years will result in many new readers undertaking screen reading. A timely method for assessing performance and preferably one that facilitates a steep learning curve will be required. MATERIALS AND METHODS: This unit screens a population of 88000 women aged 50-64 years and double reads >90% films. A record is kept of proven screen-detected cancers not recalled for assessment by either the first or second reader but correctly recalled following third-reader arbitration. Individual readers' workload and recall rates are obtained by running an annual co-writer report. The results of this 7 year prospective audit are presented. RESULTS: In total 177167 women were screened between 1/4/95 and 31/3/02 resulting in the detection of 1072 cancers. Eighty-seven cancers (8.1%) were detected after arbitration. Individual readers recall to assessment rates and percentage of cases incorrectly returned to routine recall varied. Prompt feedback of missed/misinterpreted cases allowed both experienced and inexperienced readers to modify their recall thresholds for particular mammographic abnormalities. CONCLUSION: It is recommended this audit method is adopted by all units in the NHSBSP and that the Advisory Committee for Breast Cancer Screening review the policy of single versus double reading

  3. An Ergonomic Study on Influence of Touch-screen Phone Size on Single-hand Operation Performance

    Directory of Open Access Journals (Sweden)

    Zhu Rui

    2016-01-01

    Full Text Available Touch-screen smart phones have gradually occupied the market of traditional Qwerty Phones and become the mainstream products of mobile phone industry. However, few ergonomics research has been conducted on the touch screens of smart phones, while it has led to tendosynovitis among users owing to the overuse of thumbs. Sizes of smart phones in market range from 3.0 to 7.0 inches. What’s more, 4.0 inches and above are the common size of current touch screens. Also, considering the users’ habits, one-hand operation is preferred when the other hand is occupied. This paper has collected hand parameters of 80 subjects and has adopted an experiment which includes the performance testing and surveys of subjective evaluation by means of usability evaluation. After analysing correlation between touch-screen sizes and operation performances, the result indicates that under one-hand operation, the size of touch screen affects the operation performance significantly. However, it’s hard to implement one-hand operation if the touch-screen size is over 5.7 inches. Additionally, the thickness of smart phones affects the degree of comfort remarkably.

  4. Library fingerprints: a novel approach to the screening of virtual libraries.

    Science.gov (United States)

    Klon, Anthony E; Diller, David J

    2007-01-01

    We propose a novel method to prioritize libraries for combinatorial synthesis and high-throughput screening that assesses the viability of a particular library on the basis of the aggregate physical-chemical properties of the compounds using a naïve Bayesian classifier. This approach prioritizes collections of related compounds according to the aggregate values of their physical-chemical parameters in contrast to single-compound screening. The method is also shown to be useful in screening existing noncombinatorial libraries when the compounds in these libraries have been previously clustered according to their molecular graphs. We show that the method used here is comparable or superior to the single-compound virtual screening of combinatorial libraries and noncombinatorial libraries and is superior to the pairwise Tanimoto similarity searching of a collection of combinatorial libraries.

  5. Preliminary ten year results from a randomised single centre mass screening trial for abdominal aortic aneurysm

    DEFF Research Database (Denmark)

    Lindholt, Jes Sanddal; Juul, Søren; Fasting, H

    2006-01-01

    At present, several regions and countries are considering screening for abdominal aortic aneurysm (AAA). However, The Chichester Aneurysms Screening Trial has reported poor long term benefit of screening for AAA. We therefore supplement previously published data with a preliminary analysis...

  6. Technologies for Single-Cell Isolation

    Science.gov (United States)

    Gross, Andre; Schoendube, Jonas; Zimmermann, Stefan; Steeb, Maximilian; Zengerle, Roland; Koltay, Peter

    2015-01-01

    The handling of single cells is of great importance in applications such as cell line development or single-cell analysis, e.g., for cancer research or for emerging diagnostic methods. This review provides an overview of technologies that are currently used or in development to isolate single cells for subsequent single-cell analysis. Data from a dedicated online market survey conducted to identify the most relevant technologies, presented here for the first time, shows that FACS (fluorescence activated cell sorting) respectively Flow cytometry (33% usage), laser microdissection (17%), manual cell picking (17%), random seeding/dilution (15%), and microfluidics/lab-on-a-chip devices (12%) are currently the most frequently used technologies. These most prominent technologies are described in detail and key performance factors are discussed. The survey data indicates a further increasing interest in single-cell isolation tools for the coming years. Additionally, a worldwide patent search was performed to screen for emerging technologies that might become relevant in the future. In total 179 patents were found, out of which 25 were evaluated by screening the title and abstract to be relevant to the field. PMID:26213926

  7. Technologies for Single-Cell Isolation

    Directory of Open Access Journals (Sweden)

    Andre Gross

    2015-07-01

    Full Text Available The handling of single cells is of great importance in applications such as cell line development or single-cell analysis, e.g., for cancer research or for emerging diagnostic methods. This review provides an overview of technologies that are currently used or in development to isolate single cells for subsequent single-cell analysis. Data from a dedicated online market survey conducted to identify the most relevant technologies, presented here for the first time, shows that FACS (fluorescence activated cell sorting respectively Flow cytometry (33% usage, laser microdissection (17%, manual cell picking (17%, random seeding/dilution (15%, and microfluidics/lab-on-a-chip devices (12% are currently the most frequently used technologies. These most prominent technologies are described in detail and key performance factors are discussed. The survey data indicates a further increasing interest in single-cell isolation tools for the coming years. Additionally, a worldwide patent search was performed to screen for emerging technologies that might become relevant in the future. In total 179 patents were found, out of which 25 were evaluated by screening the title and abstract to be relevant to the field.

  8. Technologies for Single-Cell Isolation.

    Science.gov (United States)

    Gross, Andre; Schoendube, Jonas; Zimmermann, Stefan; Steeb, Maximilian; Zengerle, Roland; Koltay, Peter

    2015-07-24

    The handling of single cells is of great importance in applications such as cell line development or single-cell analysis, e.g., for cancer research or for emerging diagnostic methods. This review provides an overview of technologies that are currently used or in development to isolate single cells for subsequent single-cell analysis. Data from a dedicated online market survey conducted to identify the most relevant technologies, presented here for the first time, shows that FACS (fluorescence activated cell sorting) respectively Flow cytometry (33% usage), laser microdissection (17%), manual cell picking (17%), random seeding/dilution (15%), and microfluidics/lab-on-a-chip devices (12%) are currently the most frequently used technologies. These most prominent technologies are described in detail and key performance factors are discussed. The survey data indicates a further increasing interest in single-cell isolation tools for the coming years. Additionally, a worldwide patent search was performed to screen for emerging technologies that might become relevant in the future. In total 179 patents were found, out of which 25 were evaluated by screening the title and abstract to be relevant to the field.

  9. Parameter Screening in Microfluidics Based Hydrodynamic Single-Cell Trapping

    Directory of Open Access Journals (Sweden)

    B. Deng

    2014-01-01

    Full Text Available Microfluidic cell-based arraying technology is widely used in the field of single-cell analysis. However, among developed devices, there is a compromise between cellular loading efficiencies and trapped cell densities, which deserves further analysis and optimization. To address this issue, the cell trapping efficiency of a microfluidic device with two parallel micro channels interconnected with cellular trapping sites was studied in this paper. By regulating channel inlet and outlet status, the microfluidic trapping structure can mimic key functioning units of previously reported devices. Numerical simulations were used to model this cellular trapping structure, quantifying the effects of channel on/off status and trapping structure geometries on the cellular trapping efficiency. Furthermore, the microfluidic device was fabricated based on conventional microfabrication and the cellular trapping efficiency was quantified in experiments. Experimental results showed that, besides geometry parameters, cellular travelling velocities and sizes also affected the single-cell trapping efficiency. By fine tuning parameters, more than 95% of trapping sites were taken by individual cells. This study may lay foundation in further studies of single-cell positioning in microfluidics and push forward the study of single-cell analysis.

  10. Raman-Activated Droplet Sorting (RADS) for Label-Free High-Throughput Screening of Microalgal Single-Cells.

    Science.gov (United States)

    Wang, Xixian; Ren, Lihui; Su, Yetian; Ji, Yuetong; Liu, Yaoping; Li, Chunyu; Li, Xunrong; Zhang, Yi; Wang, Wei; Hu, Qiang; Han, Danxiang; Xu, Jian; Ma, Bo

    2017-11-21

    Raman-activated cell sorting (RACS) has attracted increasing interest, yet throughput remains one major factor limiting its broader application. Here we present an integrated Raman-activated droplet sorting (RADS) microfluidic system for functional screening of live cells in a label-free and high-throughput manner, by employing AXT-synthetic industrial microalga Haematococcus pluvialis (H. pluvialis) as a model. Raman microspectroscopy analysis of individual cells is carried out prior to their microdroplet encapsulation, which is then directly coupled to DEP-based droplet sorting. To validate the system, H. pluvialis cells containing different levels of AXT were mixed and underwent RADS. Those AXT-hyperproducing cells were sorted with an accuracy of 98.3%, an enrichment ratio of eight folds, and a throughput of ∼260 cells/min. Of the RADS-sorted cells, 92.7% remained alive and able to proliferate, which is equivalent to the unsorted cells. Thus, the RADS achieves a much higher throughput than existing RACS systems, preserves the vitality of cells, and facilitates seamless coupling with downstream manipulations such as single-cell sequencing and cultivation.

  11. SCREENING FOR PERSONALITY DISORDERS

    Science.gov (United States)

    Morse, Jennifer Q.; Pilkonis, Paul A.

    2010-01-01

    A brief but valid self-report measure to screen for personality disorders (PDs) would be a valuable tool in making decisions about further assessment and in planning optimal treatments. In psychiatric and nonpsychiatric samples, we compared the validity of three screening measures: the PD scales from the Inventory of Interpersonal Problems, a self-report version of the Iowa Personality Disorder Screen, and the self-directedness scale of the Temperament and Character Inventory. Despite their different theoretical origins, the screeners were highly correlated in a range from .71 to .77. As a result, the use of multiple screeners was not a significant improvement over any individual screener, and no single screener stood out as clearly superior to the others. Each performed modestly in predicting the presence of any PD diagnosis in both the psychiatric and nonpsychiatric groups. Performance was best when predicting a more severe PD diagnosis in the psychiatric sample. The results also highlight the potential value of multiple assessments when relying on self-reports. PMID:17492920

  12. Colour screening and quark confinement

    International Nuclear Information System (INIS)

    Mack, G.

    1978-01-01

    It is proposed that in quantum chromodynamics the colour charge of gluons and of anything with zero triality is screened by a dynamic Higgs mechanism with Higgs scalars made out of gluons, but the center Z 3 of the gauge group SU(3) is left unbroken, and single quarks, which have nonzero triality, are not screened. Long range forces between them persist therefore. Given that the Higgs mechanism produces a mass gap, the most favourable configuration of field lines between e.g., quark and antiquark will be in strings analogous to magnetic field lines in a superconductor. The string confine the quarks. The screening mechanism, on the other hand, produces not only the mass gap (which leads to string formation) but is also responsible for saturation of forces, i.e. absence of bound states of six quarks, etc. (Auth.)

  13. Colour screening and quark confinement

    International Nuclear Information System (INIS)

    Mack, G.

    1978-03-01

    It is proposed that in Quantum Chromodynamics the colour charge of gluons and of anything with zero triality is screened by a dynamical Higgs mechanism with Higgs scalars made out of gluons. The center Z 3 of the gauge group SU(3) is left unbroken in this way, and single quarks, which have nonzero triality, cannot be screened. Long range forces between them persist therefore. Given that the Higgs mechanism produces a mass gap, the most favorable configuration of field lines between e.g. quark and antiquark will be in strings analogous to magnetic field lines in a superconductor. The strings confine the quarks. The screening mechanism, on the other hand, produces not only the mass gap (which leads to string formation) but is also responsible for saturation of forces, i.e. absence of bound states of six quarks etc. (orig.) [de

  14. Two against one - a case for single-sided films

    International Nuclear Information System (INIS)

    Dixon, L.

    1979-01-01

    The disadvantages of double-sided X-ray film include parallax between the double images where the film is angled to the central ray, and a cross-over effect where light from the front screen affects the back emulsion and vice versa. An investigation of the percentage of the total film density due to cross-over showed the effect varied from 28% to 47%, increasing with total density and faster screens. Kilovoltage had little influence on the effect. A single emulsion film with one screen gave an appreciable increase in radiographic sharpness and definition but required an increase by about 2.5 times in the exposure required. A very fast screen overcame this effect without comparable loss of detail. The use of single emulsion films should also reduce the thickness of cut and therefore improve sharpness in tomography. (UK)

  15. Unifying screening processes within the PROSPR consortium: a conceptual model for breast, cervical, and colorectal cancer screening.

    Science.gov (United States)

    Beaber, Elisabeth F; Kim, Jane J; Schapira, Marilyn M; Tosteson, Anna N A; Zauber, Ann G; Geiger, Ann M; Kamineni, Aruna; Weaver, Donald L; Tiro, Jasmin A

    2015-06-01

    General frameworks of the cancer screening process are available, but none directly compare the process in detail across different organ sites. This limits the ability of medical and public health professionals to develop and evaluate coordinated screening programs that apply resources and population management strategies available for one cancer site to other sites. We present a trans-organ conceptual model that incorporates a single screening episode for breast, cervical, and colorectal cancers into a unified framework based on clinical guidelines and protocols; the model concepts could be expanded to other organ sites. The model covers four types of care in the screening process: risk assessment, detection, diagnosis, and treatment. Interfaces between different provider teams (eg, primary care and specialty care), including communication and transfer of responsibility, may occur when transitioning between types of care. Our model highlights across each organ site similarities and differences in steps, interfaces, and transitions in the screening process and documents the conclusion of a screening episode. This model was developed within the National Cancer Institute-funded consortium Population-based Research Optimizing Screening through Personalized Regimens (PROSPR). PROSPR aims to optimize the screening process for breast, cervical, and colorectal cancer and includes seven research centers and a statistical coordinating center. Given current health care reform initiatives in the United States, this conceptual model can facilitate the development of comprehensive quality metrics for cancer screening and promote trans-organ comparative cancer screening research. PROSPR findings will support the design of interventions that improve screening outcomes across multiple cancer sites. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  16. Cost-effectiveness of one versus two sample faecal immunochemical testing for colorectal cancer screening

    NARCIS (Netherlands)

    S.L. Goede (Luuk); A.H.C. Roon (Aafke); J.C.I.Y. Reijerink (Jacqueline); A.J. van Vuuren (Hanneke); I. Lansdorp-Vogelaar (Iris); J.D.F. Habbema (Dik); E.J. Kuipers (Ernst); M.E. van Leerdam (Monique); M. van Ballegooijen (Marjolein)

    2013-01-01

    textabstractObjective The sensitivity and specificity of a single faecal immunochemical test (FIT) are limited. The performance of FIT screening can be improved by increasing the screening frequency or by providing more than one sample in each screening round. This study aimed to evaluate if

  17. Associations between screen time and physical activity among Spanish adolescents.

    Science.gov (United States)

    Serrano-Sanchez, Jose A; Martí-Trujillo, Sara; Lera-Navarro, Angela; Dorado-García, Cecilia; González-Henríquez, Juan J; Sanchís-Moysi, Joaquín

    2011-01-01

    Excessive time in front of a single or several screens could explain a displacement of physical activity. The present study aimed at determining whether screen-time is associated with a reduced level of moderate to vigorous physical activity (MVPA) in Spanish adolescents living in favorable environmental conditions. A multi-stage stratified random sampling method was used to select 3503 adolescents (12-18 years old) from the school population of Gran Canaria, Spain. MVPA, screen-time in front of television, computer, video game console and portable console was assessed in the classroom by fulfilling a standardized questionnaire. Bivariate and multivariate logistic regression analyses adjusted by a set of social-environmental variables were carried out. Forty-six percent of girls (95% CI±2.3%) and 26% of boys (95% CI±2.1%) did not meet the MVPA recommendations for adolescents. Major gender differences were observed in the time devoted to vigorous PA, video games and the total time spent on screen-based activities. Boys who reported 4 hours•week(-1) or more to total screen-time showed a 64% (OR = 0.61, 95% CI, 0.44-0.86) increased risk of failing to achieve the recommended adolescent MVPA level. Participation in organized physical activities and sports competitions were more strongly associated with MVPA than screen-related behaviors. No single screen-related behavior explained the reduction of MVPA in adolescents. However, the total time accumulated through several screen-related behaviors was negatively associated with MVPA level in boys. This association could be due to lower availability of time for exercise as the time devoted to sedentary screen-time activities increases. Participation in organized physical activities seems to counteract the negative impact of excessive time in front of screens on physical activity.

  18. Associations between screen time and physical activity among Spanish adolescents.

    Directory of Open Access Journals (Sweden)

    Jose A Serrano-Sanchez

    Full Text Available BACKGROUND: Excessive time in front of a single or several screens could explain a displacement of physical activity. The present study aimed at determining whether screen-time is associated with a reduced level of moderate to vigorous physical activity (MVPA in Spanish adolescents living in favorable environmental conditions. METHODOLOGY/PRINCIPAL FINDINGS: A multi-stage stratified random sampling method was used to select 3503 adolescents (12-18 years old from the school population of Gran Canaria, Spain. MVPA, screen-time in front of television, computer, video game console and portable console was assessed in the classroom by fulfilling a standardized questionnaire. Bivariate and multivariate logistic regression analyses adjusted by a set of social-environmental variables were carried out. Forty-six percent of girls (95% CI±2.3% and 26% of boys (95% CI±2.1% did not meet the MVPA recommendations for adolescents. Major gender differences were observed in the time devoted to vigorous PA, video games and the total time spent on screen-based activities. Boys who reported 4 hours•week(-1 or more to total screen-time showed a 64% (OR = 0.61, 95% CI, 0.44-0.86 increased risk of failing to achieve the recommended adolescent MVPA level. Participation in organized physical activities and sports competitions were more strongly associated with MVPA than screen-related behaviors. CONCLUSIONS/SIGNIFICANCE: No single screen-related behavior explained the reduction of MVPA in adolescents. However, the total time accumulated through several screen-related behaviors was negatively associated with MVPA level in boys. This association could be due to lower availability of time for exercise as the time devoted to sedentary screen-time activities increases. Participation in organized physical activities seems to counteract the negative impact of excessive time in front of screens on physical activity.

  19. Providing floating capabilities in latest-generation sand screens

    Energy Technology Data Exchange (ETDEWEB)

    Bowen, E.G.; Coronado, M.P. [Society of Petroleum Engineers, Richardson, TX (United States)]|[Baker Hughes, Houston, TX (United States)

    2008-10-15

    Alternative production methods are needed for the massive reserves located in the bitumen region of Canada's tar sands. The area has over 100 installations of sand screens/slotted liners in both injection and production legs using steam-assisted gravity drainage (SAGD) technology. Multiple wells must be drilled from a single pad because of the sensitive nature of the environment. With significant depths of these wells, a floating sand screen provides assurance that the sand screen will reach the desired depth. Paraffin is generally used to plug the flow access of the screen during installation. This paper discussed a new technology that has been developed to allow for sand screen installations without relying on paraffin wax to withstand differential pressure. The new technology uses a hydro-mechanical valving system incorporated into the screen design to temporarily close off the screen while being run in the hole. The paper described how the technology could provide a reliable, time-saving solution for SAGD installations when floating sand control screens are needed. The paper discussed current technology and its limitations, sand screen installation, screen design for floating applications, and additional applications. It was concluded that this technology solution provides a unique alternative to the methods currently used to install sand screens with SAGD technology in the fast growing Canadian market for bitumen recovery. 2 refs., 5 figs.

  20. Energy saving in greenhouses can be obtained by energy balance-controlled screens

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, N. E. (Univ. of Aarhus, Faculty of Agricultural Sciences, Dept. of Horticulture, Aarslev (Denmark)), e-mail: niels.andersson@agrsci.dk

    2011-03-15

    The energy screens in two greenhouses, one clad with double acrylic and one with single glass, were controlled by an energy balance model. The parameters in the model were heat transmission coefficients, air temperature in the greenhouse and outdoors, irradiance and a single constant for the solar energy efficiency. The energy consumption, screen movements and daily light integral were compared with a glass greenhouse in which the energy screens were controlled by irradiance. In the greenhouse with light-controlled screens the set point for opening and closing of the screens was 5 Wm-2. The energy-saving screens controlled by the energy balance model opened later and closed earlier than in the greenhouse with light-controlled screens. When using the energy balance model the energy saving was 14% for the glass greenhouse and 41% for the double acrylic greenhouse compared with the glass greenhouse with light-controlled screens. The air temperature was on average similar in the three greenhouses, but when the screens were controlled by energy balance the daily light integral was approximately 10% lower and the number of hours the screens were closed was prolonged with 35% for the glass-covered greenhouse and 25% for the double acrylic-covered greenhouse compared with the greenhouse with light-controlled screens. Energy peaks in connection with operation of the screens were not reduced. During the experiment Begonia elatior, Dendranthema grandiflora (Chrysanthemum), Hedera helix, Helianthus annuus, Gerbera jamesonii and Kalanchoe blossfeldiana were grown in the greenhouses. There was a trend in prolongation of the production time when the plants were grown in the glass greenhouse with energy balance control of the screens. A lower number of flowers or inflorescences were observed for some of the plant species produced in the greenhouses with energy balance-controlled screens

  1. The impact of Down syndrome screening on Taiwanese Down syndrome births: a nationwide retrospective study and a screening result from a single medical centre.

    Directory of Open Access Journals (Sweden)

    Shin-Yu Lin

    Full Text Available A retrospective analysis of the Taiwanese National Birth Defect Registration and Notification System was conducted in order to determine the live birth- and stillbirth rates in infants with Down syndrome, trisomy 18, trisomy 13 and Turner syndrome between 2001 and 2010. The objective was to investigate the impact of Down syndrome screening on the Taiwanese Down syndrome live birth rate. In addition, the results of first-trimester Down syndrome screening between 2006 and 2011, and of second-trimester quadruple testing between 2008 and 2011, were obtained from the National Taiwan University Hospital. All Taiwanese infants born between 2001 and 2010 were included in the first part of the analysis, and women receiving first-trimester Down syndrome screening or second-trimester quadruple testing from the National Taiwan University Hospital were included in the second part. The live birth rate of infants with Down syndrome, per 100 000 live births, decreased from 22.28 in 2001 to 7.79 in 2010. The ratio of liveborn DS to total DS was 48.74% in 2001, and then decreased to 25.88% in 2006, when first-trimester screening was widely introduced in Taiwan. This ratio dropped to 20.64% in 2008, when the second-trimester quadruple test was implemented. The overall positive rate in first-trimester screening in the National Taiwan University Hospital was 3.1%, with a Down syndrome detection rate of 100%; the quadruple test had values of 9.0% and 75%, respectively. The use of first-trimester screening and the second-trimester quadruple test may be responsible for the marked decrease in the Taiwanese Down syndrome live birth rate observed between 2001 and 2010.

  2. Perception of noxious compounds by contact chemoreceptors of the blowfly, Phormia regina: putative role of an odorant-bindingpProtein.

    Science.gov (United States)

    Ozaki, Mamiko; Takahara, Teruhiko; Kawahara, Yasuhiro; Wada-Katsumata, Ayako; Seno, Keiji; Amakawa, Taisaku; Yamaoka, Ryohei; Nakamura, Tadashi

    2003-05-01

    The blowfly, Phormia regina, has sensilla with four contact-chemoreceptor cells and one mechanoreceptor cell on its labellum. Three of the four chemoreceptor cells are called the sugar, the salt and the water receptor cells, respectively. However, the specificity of the remaining chemoreceptor cell, traditionally called the "fifth cell", has not yet been clarified. Referring to behavioral evaluation of the oral toxicity of monoterpenes, we measured the electrophysiological response of the "fifth cell" to these compounds. Of all the monoterpenes examined, D-limonene exhibited the strongest oral toxicity and induced the severest aversive behavior with vomiting and/or excretion in the fly. D-Limonene, when dispersed in an aqueous stimulus solution including dimethyl sulfoxide or an odorant-binding protein (OBP) found in the contact-chemoreceptor sensillum, the chemical sense-related lipophilic ligand-binding protein (CRLBP), evoked impulses from the "fifth cell". Considering the relationship between the aversive effects of monoterpenes and the response of the "fifth cell" to these effects, we propose that the "fifth cell" is a warning cell that has been differentiated as a taste system for detecting and avoiding dangerous foods. Here we suggest that in the insect contact-chemoreceptor sensillum, CRLBP carries lipophilic members of the noxious taste substances to the "fifth cell" through the aqueous sensillum lymph. This insect OBP may functionally be analogous to the von Ebner's grand protein in taste organs of mammals.

  3. Early-onset group B streptococcal disease following culture-based screening in Japan: a single center study.

    Science.gov (United States)

    Miyata, Akane; Takahashi, Hironori; Kubo, Takahiko; Watanabe, Noriyoshi; Tsukamoto, Keiko; Ito, Yushi; Sago, Haruhiko

    2012-08-01

    We investigated trends in early-onset group B streptococcal disease (EOD) after the introduction of culture-based screening in Japan. A retrospective cohort study examined EOD trends in 9506 pregnancies and 10 715 neonates at our center from 2002 to 2009. EOD occurred in four neonates (4/7332: 0.55/1000 live births). The EOD incidence among infants born to women positive for GBS by screening was 0.90 cases per 1000 live births (1/1107). In contrast, the EOD incidence among infants negative by GBS screening was 0.48 cases per 1000 live births (3/6225). Thus, of the four affected neonates, three had mothers who tested negative on antepartum GBS screening. Two neonates had symptoms of infection during labor and intrapartum antibiotic agents were administered. The other two neonates received no antibiotics because deliveries were uneventful and they were negative on GBS screening. The incidence of EOD is 0.90 cases per 1000 live births among GBS-positive women and 0.48 cases per 1000 live births among GBS-negative women. The results of our study implied that EOD can develop regardless of GBS screening and intrapartum clinical course, although the method of sample collection, indications for antibiotic prophylaxis, and the antibiotics regimen should be considered. © 2012 The Authors. Journal of Obstetrics and Gynaecology Research © 2012 Japan Society of Obstetrics and Gynecology.

  4. A single reagent radioimmunoassay for thyroxine in blood samples absorbed on filter paper for mass screening of neonatal hypothyroidism

    International Nuclear Information System (INIS)

    Nair, N.; Pillai, M.R.A.; Mani, R.S.

    1988-01-01

    A single reagent radioimmunoassay for thyroxine in blood samples absorbed on filter paper for the mass screening of neonatal hypothyroidism is described. Blood samples were collected by pricking the heel of newborn babies (3 days old) and pressing Whatman 3 filter paper against the wound. 6 mm diameter blood spots were punched out at the time of assay and incubated with 0.4 ml of a preincubated antigen-antibody complex for six hours at 37 deg C. 1 ml of 22% polyethylene glycol is used for the precipitation of antigen-antibody complex. The assay has a sensitivity of 2.2 ng/ml. 500 samples collected from newborns were analyzed in the assay and gave a mean of 117.6+-31.9 ng/ml. (author) 9 refs.; 4 figs

  5. Localization-based super-resolution imaging meets high-content screening.

    Science.gov (United States)

    Beghin, Anne; Kechkar, Adel; Butler, Corey; Levet, Florian; Cabillic, Marine; Rossier, Olivier; Giannone, Gregory; Galland, Rémi; Choquet, Daniel; Sibarita, Jean-Baptiste

    2017-12-01

    Single-molecule localization microscopy techniques have proven to be essential tools for quantitatively monitoring biological processes at unprecedented spatial resolution. However, these techniques are very low throughput and are not yet compatible with fully automated, multiparametric cellular assays. This shortcoming is primarily due to the huge amount of data generated during imaging and the lack of software for automation and dedicated data mining. We describe an automated quantitative single-molecule-based super-resolution methodology that operates in standard multiwell plates and uses analysis based on high-content screening and data-mining software. The workflow is compatible with fixed- and live-cell imaging and allows extraction of quantitative data like fluorophore photophysics, protein clustering or dynamic behavior of biomolecules. We demonstrate that the method is compatible with high-content screening using 3D dSTORM and DNA-PAINT based super-resolution microscopy as well as single-particle tracking.

  6. The paradox of screening: Rural women's views on screening for postnatal depression

    Directory of Open Access Journals (Sweden)

    Small Rhonda E

    2010-12-01

    Full Text Available Abstract Background Universal screening for postnatal depression is currently being promoted in Australia to assist detection and treatment of affected women, yet debate continues internationally about the effectiveness of screening. One rural shire in Victoria has been screening all women for postnatal depression at maternal and child health checks for many years. This paper explores the views of women affected by this intervention. Methods A postal survey was sent to an entire one year cohort of women resident in the shire and eligible for this program [n = 230]. Women were asked whether they recalled having been screened for postnatal depression and what their experience had been, including any referrals made as a result of screening. Women interested in providing additional information were invited to give a phone number for further contact. Twenty women were interviewed in-depth about their experiences. The interview sample was selected to include both depressed and non-depressed women living in town and on rural properties, who represented the range of circumstances of women living in the shire. Results The return rate for the postal survey was 62% [n = 147/230]. Eighty-seven women indicated that they were interested in further contact, 80 of whom were able to be reached by telephone and 20 were interviewed in-depth. Women had diverse views and experiences of screening. The EPDS proved to be a barrier for some women, and a facilitator for others, in accessing support and referrals. The mediating factor appeared to be a trusting relationship with the nurse able to communicate her concern for the woman and offer support and referrals if required. Conclusions Detection of maternal depression requires more than administration of a screening tool at a single time point. While this approach did work for some women, for others it actually made appropriate care and support more difficult. Rather, trained and empathic healthcare providers working

  7. Oblique-view mamography: adequacy for screening. Work in progress

    International Nuclear Information System (INIS)

    Muir, B.B.; Kirkpatrick, A.E.; Roberts, M.M.; Duffy, S.W.

    1984-01-01

    Single oblique-view mammography has been recommended for screening purposes. The authors present data indicating that using the oblique view only can allow 11% of cancers to remain undetected. The smallest and potentially curable cancers are most likely to be overlooked in this way; any possible benefit of screening is thereby reduced. Data are also presented to show that 39% of women may require other views, for reasons not necessarily related to cancer detection. It is therefore recommended that all women have four-view mammography (oblique plus craniocaudal views of each breast) at their first screening visit

  8. Artificial intelligence for breast cancer screening: Opportunity or hype?

    Science.gov (United States)

    Houssami, Nehmat; Lee, Christoph I; Buist, Diana S M; Tao, Dacheng

    2017-12-01

    Interpretation of mammography for breast cancer (BC) screening can confer a mortality benefit through early BC detection, can miss a cancer that is present or fast growing, or can result in false-positives. Efforts to improve screening outcomes have mostly focused on intensifying imaging practices (double instead of single-reading, more frequent screens, or supplemental imaging) that may add substantial resource expenditures and harms associated with population screening. Less attention has been given to making mammography screening practice 'smarter' or more efficient. Artificial intelligence (AI) is capable of advanced learning using large complex datasets and has the potential to perform tasks such as image interpretation. With both highly-specific capabilities, and also possible un-intended (and poorly understood) consequences, this viewpoint considers the promise and current reality of AI in BC detection. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Sensitivity and specificity of automated analysis of single-field non-mydriatic fundus photographs by Bosch DR Algorithm-Comparison with mydriatic fundus photography (ETDRS for screening in undiagnosed diabetic retinopathy.

    Directory of Open Access Journals (Sweden)

    Pritam Bawankar

    Full Text Available Diabetic retinopathy (DR is a leading cause of blindness among working-age adults. Early diagnosis through effective screening programs is likely to improve vision outcomes. The ETDRS seven-standard-field 35-mm stereoscopic color retinal imaging (ETDRS of the dilated eye is elaborate and requires mydriasis, and is unsuitable for screening. We evaluated an image analysis application for the automated diagnosis of DR from non-mydriatic single-field images. Patients suffering from diabetes for at least 5 years were included if they were 18 years or older. Patients already diagnosed with DR were excluded. Physiologic mydriasis was achieved by placing the subjects in a dark room. Images were captured using a Bosch Mobile Eye Care fundus camera. The images were analyzed by the Retinal Imaging Bosch DR Algorithm for the diagnosis of DR. All subjects also subsequently underwent pharmacological mydriasis and ETDRS imaging. Non-mydriatic and mydriatic images were read by ophthalmologists. The ETDRS readings were used as the gold standard for calculating the sensitivity and specificity for the software. 564 consecutive subjects (1128 eyes were recruited from six centers in India. Each subject was evaluated at a single outpatient visit. Forty-four of 1128 images (3.9% could not be read by the algorithm, and were categorized as inconclusive. In four subjects, neither eye provided an acceptable image: these four subjects were excluded from the analysis. This left 560 subjects for analysis (1084 eyes. The algorithm correctly diagnosed 531 of 560 cases. The sensitivity, specificity, and positive and negative predictive values were 91%, 97%, 94%, and 95% respectively. The Bosch DR Algorithm shows favorable sensitivity and specificity in diagnosing DR from non-mydriatic images, and can greatly simplify screening for DR. This also has major implications for telemedicine in the use of screening for retinopathy in patients with diabetes mellitus.

  10. Screening for single-chain variable fragment antibodies against multiple Cry1 toxins from an immunized mouse phage display antibody library.

    Science.gov (United States)

    Dong, Sa; Bo, Zongyi; Zhang, Cunzheng; Feng, Jianguo; Liu, Xianjin

    2018-04-01

    Single-chain variable fragment (scFv) is a kind of antibody that possess only one chain of the complete antibody while maintaining the antigen-specific binding abilities and can be expressed in prokaryotic system. In this study, scFvs against Cry1 toxins were screened out from an immunized mouse phage displayed antibody library, which was successfully constructed with capacity of 6.25 × 10 7  CFU/mL. Using the mixed and alternative antigen coating strategy and after four rounds of affinity screening, seven positive phage-scFvs against Cry1 toxins were selected and characterized. Among them, clone scFv-3H9 (MG214869) showing relative stable and high binding abilities to six Cry1 toxins was selected for expression and purification. SDS-PAGE indicated that the scFv-3H9 fragments approximately 27 kDa were successfully expressed in Escherichia coli HB2151 strain. The purified scFv-3H9 was used to establish the double antibody sandwich enzyme-linked immunosorbent assay method (DAS-ELISA) for detecting six Cry1 toxins, of which the lowest detectable limits (LOD) and the lowest quantitative limits (LOQ) were 3.14-11.07 and 8.22-39.44 ng mL -1 , respectively, with the correlation coefficient higher than 0.997. The average recoveries of Cry1 toxins from spiked rice leaf samples were ranged from 84 to 95%, with coefficient of variation (CV) less than 8.2%, showing good accuracy for the multi-residue determination of six Cry1 toxins in agricultural samples. This research suggested that the constructed phage display antibody library based on the animal which was immunized with the mixture of several antigens under the same category can be used for the quick and effective screening of generic antibodies.

  11. Optical touch screen based on waveguide sensing

    DEFF Research Database (Denmark)

    Pedersen, Henrik Chresten; Jakobsen, Michael Linde; Hanson, Steen Grüner

    2011-01-01

    We disclose a simple, optical touch screen technique based on a planar injection molded polymer waveguide, a single laser, and a small linear detector array. The solution significantly reduces the complexity and cost as compared to existing optical touch technologies. Force detection of a touching...

  12. A cost-benefit analysis of alternative device configurations for aviation-checked baggage security screening.

    Science.gov (United States)

    Jacobson, Sheldon H; Karnani, Tamana; Kobza, John E; Ritchie, Lynsey

    2006-04-01

    The terrorist attacks of September 11, 2001 have resulted in dramatic changes in aviation security. As of early 2003, an estimated 1,100 explosive detection systems (EDS) and 6,000 explosive trace detection machines (ETD) have been deployed to ensure 100% checked baggage screening at all commercial airports throughout the United States. The prohibitive costs associated with deploying and operating such devices is a serious issue for the Transportation Security Administration. This article evaluates the cost effectiveness of the explosive detection technologies currently deployed to screen checked baggage as well as new technologies that could be used in the future. Both single-device and two-device systems are considered. In particular, the expected annual direct cost of using these devices for 100% checked baggage screening under various scenarios is obtained and the tradeoffs between using single- and two-device strategies are studied. The expected number of successful threats under the different checked baggage screening scenarios with 100% checked baggage screening is also obtained. Lastly, a risk-based screening strategy proposed in the literature is analyzed. The results reported suggest that for the existing security setup, with current device costs and probability parameters, single-device systems are less costly and have fewer expected number of successful threats than two-device systems due to the way the second device affects the alarm or clear decision. The risk-based approach is found to have the potential to significantly improve security. The cost model introduced provides an effective tool for the execution of cost-benefit analyses of alternative device configurations for aviation-checked baggage security screening.

  13. The cost-effectiveness of 10 antenatal syphilis screening and treatment approaches in Peru, Tanzania, and Zambia.

    Science.gov (United States)

    Terris-Prestholt, Fern; Vickerman, Peter; Torres-Rueda, Sergio; Santesso, Nancy; Sweeney, Sedona; Mallma, Patricia; Shelley, Katharine D; Garcia, Patricia J; Bronzan, Rachel; Gill, Michelle M; Broutet, Nathalie; Wi, Teodora; Watts, Charlotte; Mabey, David; Peeling, Rosanna W; Newman, Lori

    2015-06-01

    Rapid plasma reagin (RPR) is frequently used to test women for maternal syphilis. Rapid syphilis immunochromatographic strip tests detecting only Treponema pallidum antibodies (single RSTs) or both treponemal and non-treponemal antibodies (dual RSTs) are now available. This study assessed the cost-effectiveness of algorithms using these tests to screen pregnant women. Observed costs of maternal syphilis screening and treatment using clinic-based RPR and single RSTs in 20 clinics across Peru, Tanzania, and Zambia were used to model the cost-effectiveness of algorithms using combinations of RPR, single, and dual RSTs, and no and mass treatment. Sensitivity analyses determined drivers of key results. Although this analysis found screening using RPR to be relatively cheap, most (>70%) true cases went untreated. Algorithms using single RSTs were the most cost-effective in all observed settings, followed by dual RSTs, which became the most cost-effective if dual RST costs were halved. Single test algorithms dominated most sequential testing algorithms, although sequential algorithms reduced overtreatment. Mass treatment was relatively cheap and effective in the absence of screening supplies, though treated many uninfected women. This analysis highlights the advantages of introducing RSTs in three diverse settings. The results should be applicable to other similar settings. Copyright © 2015 International Federation of Gynecology and Obstetrics. All rights reserved.

  14. High-Throughput Accurate Single-Cell Screening of Euglena gracilis with Fluorescence-Assisted Optofluidic Time-Stretch Microscopy.

    Directory of Open Access Journals (Sweden)

    Baoshan Guo

    Full Text Available The development of reliable, sustainable, and economical sources of alternative fuels is an important, but challenging goal for the world. As an alternative to liquid fossil fuels, algal biofuel is expected to play a key role in alleviating global warming since algae absorb atmospheric CO2 via photosynthesis. Among various algae for fuel production, Euglena gracilis is an attractive microalgal species as it is known to produce wax ester (good for biodiesel and aviation fuel within lipid droplets. To date, while there exist many techniques for inducing microalgal cells to produce and accumulate lipid with high efficiency, few analytical methods are available for characterizing a population of such lipid-accumulated microalgae including E. gracilis with high throughout, high accuracy, and single-cell resolution simultaneously. Here we demonstrate high-throughput, high-accuracy, single-cell screening of E. gracilis with fluorescence-assisted optofluidic time-stretch microscopy-a method that combines the strengths of microfluidic cell focusing, optical time-stretch microscopy, and fluorescence detection used in conventional flow cytometry. Specifically, our fluorescence-assisted optofluidic time-stretch microscope consists of an optical time-stretch microscope and a fluorescence analyzer on top of a hydrodynamically focusing microfluidic device and can detect fluorescence from every E. gracilis cell in a population and simultaneously obtain its image with a high throughput of 10,000 cells/s. With the multi-dimensional information acquired by the system, we classify nitrogen-sufficient (ordinary and nitrogen-deficient (lipid-accumulated E. gracilis cells with a low false positive rate of 1.0%. This method holds promise for evaluating cultivation techniques and selective breeding for microalgae-based biofuel production.

  15. DEVELOPMENT AND INVESTIGATION OF LAYOUT OF ACTIVE SCREENING SYSTEM OF THE MAGNETIC FIELD GENERATED BY GROUP OF OVERHEAD TRANSMISSION LINES

    Directory of Open Access Journals (Sweden)

    B. I. Kuznetsov

    2018-04-01

    Full Text Available Purpose. Development and field experimental research of layout of the single-circuit active screening system of the magnetic field generated by group of high voltage transmission lines in residential area is given. Methodology. Mathematical model of magnetic field, generated by group of high voltage transmission lines in residential area, based of the experimental values of magnetic field flux density in given points on the basis of optimization problem solving is improved. The objective of the synthesis of the single circuit active screening system is to determine their number, configuration, spatial arrangement, wiring diagrams and compensation cables currents, setting algorithm of the control systems as well as the resulting value of the magnetic flux density at the points of the protected space. Synthesis of the full-scale model of active screening system is reduced to the problem of multiobjective nonlinear programming with constraints in which calculation of the objective functions and constraints are carried out on the basis of the Maxwell equations solutions in the quasi-stationary approximation. The problem is solved by a stochastic multiswarm multi-agent particles optimization. Results. The single-circuit active screening system synthesis results for reduction of a magnetic field generated by group of high voltage transmission lines in residential area is given. Field experimental researches of the single-circuit active screening system of the magnetic field generated by group of high voltage transmission lines in residential area with various control algorithms is given. Originality. For the first time out the development and field experimental studies of the single-circuit active screening system of the magnetic field generated by group of high voltage transmission lines in residential area are carried out. Practical value. Practical recommendations on reasonable choice of the spatial arrangement of compensating cables of single

  16. Gestalt Theory in Visual Screen Design — A New Look at an old subject

    OpenAIRE

    Chang, D.; Dooley, L.; Tuovinen, J. E

    2002-01-01

    Although often presented as a single basis for educational visual screen design, Gestalt theory is not a single small set of visual principles uniformly applied by all designers. In fact, it appears that instructional visual design literature often deals with only a small set of Gestalt laws. In this project Gestalt literature was consulted to distil the most relevant Gestalt laws for educational visual screen design. Eleven laws were identified. They deal with balance/symmetry, continuation,...

  17. Linear antenna of an arbitrary orientation and position in cylindric screen

    International Nuclear Information System (INIS)

    Prijmenko, S.D.; Papkovich, V.G.; Khizhnyak, N.A.

    1991-01-01

    An equation of the linear antenna in cylindric screen is formulated. Using the averaging method a solution of this equation for the antenna of arbitrary orientation which does not contact the screen walls or contacts them in one or two ends is received. The obtained asymptotic expression for stream permits to describe in a single manner the case of resonance and non-resonance scattering. These results may be applied in design of UHF and accelerating installations using cylindric screens charged with linear vibrators. 9 refs. (author)

  18. Central projections of gustatory receptor neurons in the medial and the lateral sensilla styloconica of Helicoverpa armigera larvae.

    Directory of Open Access Journals (Sweden)

    Qing-Bo Tang

    Full Text Available Food selection behavior of lepidopteran larvae is predominantly governed by the activation of taste neurons present in two sensilla styloconica located on the galea of the maxilla. In this study, we present the ultrastructure of the sensilla styloconica and the central projection pattern of their associated receptor neurons in larvae of the heliothine moth, Helicoverpa armigera. By means of light microscopy and scanning electron microscopy, the previous findings of two morphologically fairly similar sensilla comprising a socketed conic tip inserted into a large peg were confirmed. However, the peg size of the medial sensillum was found to be significantly bigger than that of the lateral sensillum. The sensory neurons derived from each sensillum styloconicum were mapped separately using anterograde staining experiments combined with confocal laser-scanning microscopy. For determining the afferents' target regions relative to each other, we reconstructed the labeled axons and placed them into a common reference framework. The sensory axons from both sensilla projected via the ipsilateral maxillary nerve to the suboesophageal ganglion and further through the ipsilateral circumoesophageal connective to the brain. In the suboesophageal ganglion, the sensory projections targeted two areas of the ipsilateral maxillary neuropil, one located in the ventrolateral neuromere and the other adjacent to the neuromere midline. In the brain, the axon terminals targeted the dorso-anterior area of the ipsilateral tritocerebrum. As confirmed by the three-dimensional reconstructions, the target regions of the neural projections originating from each of the two sensilla styloconica were identical.

  19. Central projections of gustatory receptor neurons in the medial and the lateral sensilla styloconica of Helicoverpa armigera larvae.

    Science.gov (United States)

    Tang, Qing-Bo; Zhan, Huan; Cao, Huan; Berg, Bente G; Yan, Feng-Ming; Zhao, Xin-Cheng

    2014-01-01

    Food selection behavior of lepidopteran larvae is predominantly governed by the activation of taste neurons present in two sensilla styloconica located on the galea of the maxilla. In this study, we present the ultrastructure of the sensilla styloconica and the central projection pattern of their associated receptor neurons in larvae of the heliothine moth, Helicoverpa armigera. By means of light microscopy and scanning electron microscopy, the previous findings of two morphologically fairly similar sensilla comprising a socketed conic tip inserted into a large peg were confirmed. However, the peg size of the medial sensillum was found to be significantly bigger than that of the lateral sensillum. The sensory neurons derived from each sensillum styloconicum were mapped separately using anterograde staining experiments combined with confocal laser-scanning microscopy. For determining the afferents' target regions relative to each other, we reconstructed the labeled axons and placed them into a common reference framework. The sensory axons from both sensilla projected via the ipsilateral maxillary nerve to the suboesophageal ganglion and further through the ipsilateral circumoesophageal connective to the brain. In the suboesophageal ganglion, the sensory projections targeted two areas of the ipsilateral maxillary neuropil, one located in the ventrolateral neuromere and the other adjacent to the neuromere midline. In the brain, the axon terminals targeted the dorso-anterior area of the ipsilateral tritocerebrum. As confirmed by the three-dimensional reconstructions, the target regions of the neural projections originating from each of the two sensilla styloconica were identical.

  20. High-throughput, label-free, single-cell, microalgal lipid screening by machine-learning-equipped optofluidic time-stretch quantitative phase microscopy.

    Science.gov (United States)

    Guo, Baoshan; Lei, Cheng; Kobayashi, Hirofumi; Ito, Takuro; Yalikun, Yaxiaer; Jiang, Yiyue; Tanaka, Yo; Ozeki, Yasuyuki; Goda, Keisuke

    2017-05-01

    The development of reliable, sustainable, and economical sources of alternative fuels to petroleum is required to tackle the global energy crisis. One such alternative is microalgal biofuel, which is expected to play a key role in reducing the detrimental effects of global warming as microalgae absorb atmospheric CO 2 via photosynthesis. Unfortunately, conventional analytical methods only provide population-averaged lipid amounts and fail to characterize a diverse population of microalgal cells with single-cell resolution in a non-invasive and interference-free manner. Here high-throughput label-free single-cell screening of lipid-producing microalgal cells with optofluidic time-stretch quantitative phase microscopy was demonstrated. In particular, Euglena gracilis, an attractive microalgal species that produces wax esters (suitable for biodiesel and aviation fuel after refinement), within lipid droplets was investigated. The optofluidic time-stretch quantitative phase microscope is based on an integration of a hydrodynamic-focusing microfluidic chip, an optical time-stretch quantitative phase microscope, and a digital image processor equipped with machine learning. As a result, it provides both the opacity and phase maps of every single cell at a high throughput of 10,000 cells/s, enabling accurate cell classification without the need for fluorescent staining. Specifically, the dataset was used to characterize heterogeneous populations of E. gracilis cells under two different culture conditions (nitrogen-sufficient and nitrogen-deficient) and achieve the cell classification with an error rate of only 2.15%. The method holds promise as an effective analytical tool for microalgae-based biofuel production. © 2017 International Society for Advancement of Cytometry. © 2017 International Society for Advancement of Cytometry.

  1. Gastric cancer screening of a high-risk population in Japan using serum pepsinogen and barium digital radiography.

    Science.gov (United States)

    Ohata, Hiroshi; Oka, Masashi; Yanaoka, Kimihiko; Shimizu, Yasuhito; Mukoubayashi, Chizu; Mugitani, Kouichi; Iwane, Masataka; Nakamura, Hideya; Tamai, Hideyuki; Arii, Kenji; Nakata, Hiroya; Yoshimura, Noriko; Takeshita, Tetsuya; Miki, Kazumasa; Mohara, Osamu; Ichinose, Masao

    2005-10-01

    With the aim of developing more efficient gastric cancer screening programs for use in Japan, we studied a new screening program that combines serum pepsinogen (PG) testing and barium digital radiography (DR). A total of 17 647 middle-aged male subjects underwent workplace screening over a 7-year period using a combination of PG testing and DR. This program's effectiveness, as well as other characteristics of the program, was analyzed. Forty-nine cases of gastric cancer were detected (comprising 88% early cancer cases). The detection rate was 0.28%, and the positive predictive value was 0.85%. The PG test detected 63.3% of cases, DR detected 69.4% of cases, and both tests were positive in 32.7% of cancer cases. The two methods were almost equally effective, and were considerably more effective than conventional screening using photofluorography. Each screening method detected a distinct gastric cancer subgroup; the PG test efficiently detected asymptomatic small early cancer with intestinal type histology, while DR was efficient at detecting cancers with depressed or ulcerated morphology and diffuse type histology. The cost for the detection of a single cancer was much less than that for conventional screening. In fact, it is possible to further reduce the cost of detecting a single cancer to a cost comparable to that of surgically resecting a single gastric cancer. Thus, it is probable that a highly efficient gastric cancer screening system can be implemented by combining the two screening methods. Such a screening program would be beneficial in a population at high risk for gastric cancer.

  2. Single Frequency Impedance Analysis on Reduced Graphene Oxide Screen-Printed Electrode for Biomolecular Detection.

    Science.gov (United States)

    Rajesh; Singal, Shobhita; Kotnala, Ravinder K

    2017-10-01

    A biofunctionalized reduced graphene oxide (rGO)-modified screen-printed carbon electrode (SPCE) was constructed as an immunosensor for C-reactive protein (CRP) detection, a biomarker released in early stage acute myocardial infarction. A different approach of single frequency analysis (SFA) study was utilized for the biomolecular sensing, by monitoring the response in phase angle changes obtained at an optimized frequency resulting from antigen-antibody interactions. A set of measurements were carried out to optimize a frequency where a maximum change in phase angle was observed, and in this case, we found it at around 10 Hz. The bioelectrode was characterized by contact angle measurements, scanning electron microscopy, and electrochemical techniques. A concentration-dependent response of immunosensor to CRP with the change in phase angle, at a fixed frequency of 10 Hz, was found to be in the range of 10 ng mL -1 to 10 μg mL -1 in PBS and was fit quantitative well with the Hill-Langmuir equation. Based on the concentration-response data, the dissociation constant (K d ) was found to be 3.5 nM (with a Hill coefficient n = 0.57), which indicated a negative cooperativity with high anti-CRP (antibody)-CRP (antigen) binding at the electrode surface. A low-frequency analysis of sensing with an ease of measurement on a disposable electroactive rGO-modified electrode with high selectivity and sensitivity makes it a potential tool for biological sensors.

  3. Smart material screening machines using smart materials and controls

    Science.gov (United States)

    Allaei, Daryoush; Corradi, Gary; Waigand, Al

    2002-07-01

    The objective of this product is to address the specific need for improvements in the efficiency and effectiveness in physical separation technologies in the screening areas. Currently, the mining industry uses approximately 33 billion kW-hr per year, costing 1.65 billion dollars at 0.05 cents per kW-hr, of electrical energy for physical separations. Even though screening and size separations are not the single most energy intensive process in the mining industry, they are often the major bottleneck in the whole process. Improvements to this area offer tremendous potential in both energy savings and production improvements. Additionally, the vibrating screens used in the mining processing plants are the most costly areas from maintenance and worker health and safety point of views. The goal of this product is to reduce energy use in the screening and total processing areas. This goal is accomplished by developing an innovative screening machine based on smart materials and smart actuators, namely smart screen that uses advanced sensory system to continuously monitor the screening process and make appropriate adjustments to improve production. The theory behind the development of Smart Screen technology is based on two key technologies, namely smart actuators and smart Energy Flow ControlT (EFCT) strategies, developed initially for military applications. Smart Screen technology controls the flow of vibration energy and confines it to the screen rather than shaking much of the mass that makes up the conventional vibratory screening machine. Consequently, Smart Screens eliminates and downsizes many of the structural components associated with conventional vibratory screening machines. As a result, the surface area of the screen increases for a given envelope. This increase in usable screening surface area extends the life of the screens, reduces required maintenance by reducing the frequency of screen change-outs and improves throughput or productivity.

  4. Modified Moliere's screening parameter and its impact on multiple coulomb scattering

    International Nuclear Information System (INIS)

    Striganov, Sergei

    2015-01-01

    The Moliere approximation of elastic Coulomb scattering cross-sections plays an important role in accurate description of multiple scattering, non-ionisation energy, DPA radiation damage etc. The cross-section depends only on a single parameter that describes the atomic screening. Moliere calculated the screening angle for the Tomas-Fermi distribution of electrons in atoms. In this paper, the screening parameter was recalculated using a more accurate atomic form-factor obtained from the self-consistent Dirac-Hartree-Fock-Slater computations. For relativistic particles, the new screening angle can differ from the Moliere approximation by up to 50%. At the same time, it is rather close to other independent calculations. At low energies, the new screening angle is different for positrons and electrons. The positron screening parameter is much larger than the electron one for heavy nuclei at energies of ∼Z keV. The impact of the screening angle on particle transport and calculated quantities is discussed. (authors)

  5. Added value of second biopsy target in screen-detected widespread suspicious breast calcifications.

    Science.gov (United States)

    Falkner, Nathalie M; Hince, Dana; Porter, Gareth; Dessauvagie, Ben; Jeganathan, Sanjay; Bulsara, Max; Lo, Glen

    2018-06-01

    There is controversy on the optimal work-up of screen-detected widespread breast calcifications: whether to biopsy a single target or multiple targets. This study evaluates agreement between multiple biopsy targets within the same screen-detected widespread (≥25 mm) breast calcification to determine if the second biopsy adds value. Retrospective observational study of women screened in a statewide general population risk breast cancer mammographic screening program from 2009 to 2016. Screening episodes recalled for widespread calcifications where further views indicated biopsy, and two or more separate target areas were sampled within the same lesion were included. Percentage agreement and Cohen's Kappa were calculated. A total of 293317 women were screened during 761124 separate episodes with recalls for widespread calcifications in 2355 episodes. In 171 women, a second target was biopsied within the same lesion. In 149 (86%) cases, the second target biopsy result agreed with the first biopsy (κ = 0.6768). Agreement increased with increasing mammography score (85%, 86% and 92% for score 3, 4 and 5 lesions). Same day multiple biopsied lesions were three times more likely to yield concordant results compared to post-hoc second target biopsy cases. While a single target biopsy is sufficient to discriminate a benign vs. malignant diagnosis in most cases, in 14% there is added value in performing a second target biopsy. Biopsies performed prospectively are more likely to yield concordant results compared to post-hoc second target biopsy cases, suggesting a single prospective biopsy may be sufficient when results are radiological-pathological concordant; discordance still requires repeat sampling. © 2018 The Royal Australian and New Zealand College of Radiologists.

  6. Is computer aided detection (CAD) cost effective in screening mammography? A model based on the CADET II study

    Science.gov (United States)

    2011-01-01

    Background Single reading with computer aided detection (CAD) is an alternative to double reading for detecting cancer in screening mammograms. The aim of this study is to investigate whether the use of a single reader with CAD is more cost-effective than double reading. Methods Based on data from the CADET II study, the cost-effectiveness of single reading with CAD versus double reading was measured in terms of cost per cancer detected. Cost (Pound (£), year 2007/08) of single reading with CAD versus double reading was estimated assuming a health and social service perspective and a 7 year time horizon. As the equipment cost varies according to the unit size a separate analysis was conducted for high, average and low volume screening units. One-way sensitivity analyses were performed by varying the reading time, equipment and assessment cost, recall rate and reader qualification. Results CAD is cost increasing for all sizes of screening unit. The introduction of CAD is cost-increasing compared to double reading because the cost of CAD equipment, staff training and the higher assessment cost associated with CAD are greater than the saving in reading costs. The introduction of single reading with CAD, in place of double reading, would produce an additional cost of £227 and £253 per 1,000 women screened in high and average volume units respectively. In low volume screening units, the high cost of purchasing the equipment will results in an additional cost of £590 per 1,000 women screened. One-way sensitivity analysis showed that the factors having the greatest effect on the cost-effectiveness of CAD with single reading compared with double reading were the reading time and the reader's professional qualification (radiologist versus advanced practitioner). Conclusions Without improvements in CAD effectiveness (e.g. a decrease in the recall rate) CAD is unlikely to be a cost effective alternative to double reading for mammography screening in UK. This study

  7. Developments in dual-energy, single-exposure chest radiography

    International Nuclear Information System (INIS)

    Ho Jungtsuoe.

    1990-01-01

    Conventional chest radiography (CCR), the most commonly performed technique for the diagnosis of lung cancer, does not detect a high percentage of these tumors. One reason for errors is the overlap of tumor image with bone image in a chest radiograph. Dual-energy (DE) radiography has been suggested as the most effective method to eliminate bone contrast for better lung tumor visualization. DE radiography also provides a bone image from which benign nodules can be identified by the presence of nodule calcification. The purpose of this study is to evaluate the performance of a film-screen based DE, single exposure technique in lung nodule detection and to improve its performance by both hardware (HD) and software developments (SD) to increase the accuracy of lung cancer diagnosis. Previous implementation of the technique resulted in small residual tissue contrast and incomplete tissue subtraction due to screen selection and x-ray beam hardening, respectively. HD, including uses of a new screen pair (Y 2 O 2 S/CaWO 4 ) and a K-edge filter (europium), were studied to improve residual tissue contrast by increasing the energy separation. Successful SD included a three-dimensional interpolation algorithm and noise suppression methods to achieve complete tissue subtraction and noise reduction, respectively. The results show that the new screen pair performed better than LaOBr/CaWo 4 ; the use of K-edge filter produced more residual tissue contrast than that obtained without it. Even though the dual exposure technique performed better than the single exposure technique in a simulated lung nodule detection study, the difference between the two techniques was statistically insignificant and they both performed better than CCR. Based on these encouraging results, the author concludes that the film-screen based DE, single exposure technique, with the HD and SD holds promise for further clinical study

  8. Screening in toddlers and preschoolers at risk for autism spectrum disorder: Evaluating a novel mobile-health screening tool.

    Science.gov (United States)

    Kanne, Stephen M; Carpenter, Laura Arnstein; Warren, Zachary

    2018-05-07

    There are many available tools with varying levels of accuracy designed to screen for Autism Spectrum Disorder (ASD) in young children, both in the general population and specifically among those referred for developmental concerns. With burgeoning waitlists for comprehensive diagnostic ASD assessments, finding accurate methods and tools for advancing diagnostic triage becomes increasingly important. The current study compares the efficacy of four oft used paper and pencil measures, the Modified Checklist for Autism in Toddlers Revised with Follow-up, the Social Responsiveness Scale, Second Edition, and the Social Communication Questionnaire, and the Child Behavior Checklist to a novel mobile-health screening tool developed by Cognoa, Inc. (Cognoa) in a group of children 18-72 months of age. The Cognoa tool may have potential benefits as it integrates a series of parent-report questions with remote clinical ratings of brief video segments uploaded via parent's smartphones to calculate level of ASD risk. Participants were referred to one of three tertiary care diagnostic centers for ASD-related concerns (n = 230) and received a best estimate ASD diagnosis. Analysis and comparison of psychometric properties indicated potential advantages for Cognoa within this clinical sample across age ranges not often covered by another single measure/tool. Autism Res 2018. © 2018 International Society for Autism Research, Wiley Periodicals, Inc. With the wait times getting longer for comprehensive Autism Spectrum Disorder (ASD) diagnostic assessments, it is becoming increasingly important to find accurate tools to screen for ASD. The current study compares four screening measures that have been in use for some time to a novel mobile-health screening tool, called Cognoa. The Cognoa tool is novel because it integrates parent-report questions with clinical ratings of brief video segments uploaded via parent's smartphones to calculate ASD risk. Two hundred thirty children who

  9. Perinatal depression and screening among Aboriginal Australians in the Kimberley.

    Science.gov (United States)

    Kotz, Jayne; Munns, Ailsa; Marriott, Rhonda; Marley, Julia V

    2016-02-01

    Adhoc culturally questionable perinatal mental-health screening among Aboriginal women in the Kimberley. Mental-health issues, substance abuse and suicide attempts are high among young Aboriginal women in Australia. There is no evidence that the Edinburgh Postnatal Depression Scale (EPDS) is effective or culturally safe. Screening practices are complicated by limited understanding of the complex cultural interface between Western and Aboriginal beliefs and notions about health and mental-health. What is the current context of perinatal mental-health screening practices among Aboriginal women in the Kimberley and what might be considered a culturally safe approach? A review of the literature and exploration of current screening practices preceded community participatory action research (CPAR) of perinatal mental-health screening. More than 100 Kimberley women and 72 health practitioners contributed to this joint strategic body of work. Recommendations for practice include one single culturally appropriate Kimberley version of the EPDS.

  10. Identification of the Female-Produced Sex Pheromone of an Invasive Greenhouse Pest, the European Pepper Moth (Duponchelia fovealis).

    Science.gov (United States)

    Molnár, Péter Béla; Bognár, Csengele; Erdei, Anna Laura; Fujii, Takeshi; Vági, Pál; Jósvai, Júlia Katalin; Kárpáti, Zsolt

    2018-03-01

    The European pepper moth (Duponchelia fovealis, Lepidoptera, Crambidae, Spilomelinae) is an invasive pest of greenhouses in many countries, causing serious damages to horticultural plants. Coupled gas chromatographic-electroantennographic detection analysis of the female gland extract revealed two antennally active peaks. Using coupled gas chromatography-mass spectrometry (GC-MS), one was identified as (Z)-11-hexadecenal (Z11-16:Ald); however, further analysis on different types of capillary columns indicated that the second active compound has two different isomers, (E)-13-octadecenal (E13-18:Ald) and (Z)-13-octadecenal (Z13-18:Ald). The approximate ratio of E13-18:Ald, Z13-18:Ald and Z11-16:Ald in the crude pheromone gland extract was 10:1:0.1, respectively. Single sensillum recordings showed that there was one sensory neuron that responded with a high amplitude spike to both E13-18:Ald and Z13-18:Ald, while another neuron housed in the same sensillum responded to Z11-16:Ald. Field evaluation of the identified compounds indicated that the E13-18:Ald was necessary to evoke the attraction of males; although the presence of Z13-18:Ald and Z11-16:Ald increased the catches in traps. The highest number of caught males was achieved when E13-18:Ald, Z13-18:Ald and Z11-16:Ald were present in baits in the same ratio as in the female gland extract. This pheromone can be used in a monitoring strategy and could potentially lead to the development of mating disruption.

  11. Cost implications of PSA screening differ by age.

    Science.gov (United States)

    Rao, Karthik; Liang, Stella; Cardamone, Michael; Joshu, Corinne E; Marmen, Kyle; Bhavsar, Nrupen; Nelson, William G; Ballentine Carter, H; Albert, Michael C; Platz, Elizabeth A; Pollack, Craig E

    2018-05-09

    Multiple guidelines seek to alter rates of prostate-specific antigen (PSA)-based prostate cancer screening. The costs borne by payers associated with PSA-based screening for men of different age groups-including the costs of screening and subsequent diagnosis, treatment, and adverse events-remain uncertain. We sought to develop a model of PSA costs that could be used by payers and health care systems to inform cost considerations under a range of different scenarios. We determined the prevalence of PSA screening among men aged 50 and higher using 2013-2014 data from a large, multispecialty group, obtained reimbursed costs associated with screening, diagnosis, and treatment from a commercial health plan, and identified transition probabilities for biopsy, diagnosis, treatment, and complications from the literature to generate a cost model. We estimated annual total costs for groups of men ages 50-54, 55-69, and 70+ years, and varied annual prostate cancer screening prevalence in each group from 5 to 50% and tested hypothetical examples of different test characteristics (e.g., true/false positive rate). Under the baseline screening patterns, costs of the PSA screening represented 10.1% of the total costs; costs of biopsies and associated complications were 23.3% of total costs; and, although only 0.3% of all screen eligible patients were treated, they accounted for 66.7% of total costs. For each 5-percentage point decrease in PSA screening among men aged 70 and older for a single calendar year, total costs associated with prostate cancer screening decreased by 13.8%. For each 5-percentage point decrease in PSA screening among men 50-54 and 55-69 years old, costs were 2.3% and 7.3% lower respectively. With constrained financial resources and with national pressure to decrease use of clinically unnecessary PSA-based prostate cancer screening, there is an opportunity for cost savings, especially by focusing on the downstream costs disproportionately associated with

  12. Screening and surveillance of workers exposed to mineral dusts

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, G.R.

    1997-12-31

    This publication resulted from a World Health Organisation initiated project to investigate the harmonisation of definitions, approaches and methodologies for the screening and surveillance of workers exposed to mineral dust. The first part of the book provides definitions of screening and surveillance and describes the main elements of such programmes. The second part discusses the practical aspect of the screening and surveillance of working populations exposed to crystalline silica, coal mine dust and asbestos. Although no single set of guidelines is applicable to the development and implementation of a programme for the screening and surveillance of workers exposed to mineral dust, the recommendations, together with certain caveats, should provide a useful starting point. Annexes provide examples of existing programmes in various countries and environments and discuss the use and interpretation of questionnaires, lung spirometry and chest radiography. Overall the book should be of interest to occupational health professionals.

  13. Screens

    OpenAIRE

    2016-01-01

    This Sixth volume in the series The Key Debates. Mutations and Appropriations in European Film Studies investigates the question of screens in the context both of the dematerialization due to digitalization and the multiplication of media screens. Scholars offer various infomations and theories of topics such as the archeology of screen, film and media theories, contemporary art, pragmatics of new ways of screening (from home video to street screening).

  14. A mix-and-read drop-based in vitro two-hybrid method for screening high-affinity peptide binders

    Science.gov (United States)

    Cui, Naiwen; Zhang, Huidan; Schneider, Nils; Tao, Ye; Asahara, Haruichi; Sun, Zhiyi; Cai, Yamei; Koehler, Stephan A.; de Greef, Tom F. A.; Abbaspourrad, Alireza; Weitz, David A.; Chong, Shaorong

    2016-01-01

    Drop-based microfluidics have recently become a novel tool by providing a stable linkage between phenotype and genotype for high throughput screening. However, use of drop-based microfluidics for screening high-affinity peptide binders has not been demonstrated due to the lack of a sensitive functional assay that can detect single DNA molecules in drops. To address this sensitivity issue, we introduced in vitro two-hybrid system (IVT2H) into microfluidic drops and developed a streamlined mix-and-read drop-IVT2H method to screen a random DNA library. Drop-IVT2H was based on the correlation between the binding affinity of two interacting protein domains and transcriptional activation of a fluorescent reporter. A DNA library encoding potential peptide binders was encapsulated with IVT2H such that single DNA molecules were distributed in individual drops. We validated drop-IVT2H by screening a three-random-residue library derived from a high-affinity MDM2 inhibitor PMI. The current drop-IVT2H platform is ideally suited for affinity screening of small-to-medium-sized libraries (103–106). It can obtain hits within a single day while consuming minimal amounts of reagents. Drop-IVT2H simplifies and accelerates the drop-based microfluidics workflow for screening random DNA libraries, and represents a novel alternative method for protein engineering and in vitro directed protein evolution. PMID:26940078

  15. Colorectal cancer mortality 10 years after a single round of guaiac faecal occult blood test gFOBT screening

    DEFF Research Database (Denmark)

    Bjerrum, Andreas; Andersen, Ole; Fischer, Anders

    2016-01-01

    BACKGROUND: In Denmark, colorectal cancer (CRC) is the third most frequent cancer. Randomised trials have shown that guaiac faecal occult blood test (gFOBT) screening can reduce CRC mortality, but a recent large randomised study from Finland did not find any effect. A feasibility study was carried...... out in Denmark in 2005-2006 where residents aged 50-74 years in 2 Danish counties were invited once to participate in gFOBT screening. We used the unique Danish registers to assess the impact of gFOBT screening in this group on CRC incidence and mortality. METHODS: In this cohort study, we followed...... a median follow-up time of 8.9 years, the CRC mortality was significantly lower in the screening group than in the reference group with an adjusted HR (aHR) of 0.92 (95% CI 0.86 to 0.99), while the aHR for all-cause mortality was 0.95 (95% CI 0.94 to 0.96). For screening participants, the aHR for CRC...

  16. An x-ray-based capsule for colorectal cancer screening incorporating single photon counting technology

    Science.gov (United States)

    Lifshitz, Ronen; Kimchy, Yoav; Gelbard, Nir; Leibushor, Avi; Golan, Oleg; Elgali, Avner; Hassoon, Salah; Kaplan, Max; Smirnov, Michael; Shpigelman, Boaz; Bar-Ilan, Omer; Rubin, Daniel; Ovadia, Alex

    2017-03-01

    An ingestible capsule for colorectal cancer screening, based on ionizing-radiation imaging, has been developed and is in advanced stages of system stabilization and clinical evaluation. The imaging principle allows future patients using this technology to avoid bowel cleansing, and to continue the normal life routine during procedure. The Check-Cap capsule, or C-Scan ® Cap, imaging principle is essentially based on reconstructing scattered radiation, while both radiation source and radiation detectors reside within the capsule. The radiation source is a custom-made radioisotope encased in a small canister, collimated into rotating beams. While traveling along the human colon, irradiation occurs from within the capsule towards the colon wall. Scattering of radiation occurs both inside and outside the colon segment; some of this radiation is scattered back and detected by sensors onboard the capsule. During procedure, the patient receives small amounts of contrast agent as an addition to his/her normal diet. The presence of contrast agent inside the colon dictates the dominant physical processes to become Compton Scattering and X-Ray Fluorescence (XRF), which differ mainly by the energy of scattered photons. The detector readout electronics incorporates low-noise Single Photon Counting channels, allowing separation between the products of these different physical processes. Separating between radiation energies essentially allows estimation of the distance from the capsule to the colon wall, hence structural imaging of the intraluminal surface. This allows imaging of structural protrusions into the colon volume, especially focusing on adenomas that may develop into colorectal cancer.

  17. Screening for mutations in human alpha-globin genes by nonradioactive single-strand conformation polymorphism

    Directory of Open Access Journals (Sweden)

    Jorge S.B.

    2003-01-01

    Full Text Available Point mutations and small insertions or deletions in the human alpha-globin genes may produce alpha-chain structural variants and alpha-thalassemia. Mutations can be detected either by direct DNA sequencing or by screening methods, which select the mutated exon for sequencing. Although small (about 1 kb, 3 exons and 2 introns, the alpha-globin genes are duplicate (alpha2 and alpha1 and highy G-C rich, which makes them difficult to denature, reducing sequencing efficiency and causing frequent artifacts. We modified some conditions for PCR and electrophoresis in order to detect mutations in these genes employing nonradioactive single-strand conformation polymorphism (SSCP. Primers previously described by other authors for radioactive SSCP and phast-SSCP plus denaturing gradient gel electrophoresis were here combined and the resultant fragments (6 new besides 6 original per alpha-gene submitted to silver staining SSCP. Nine structural and one thalassemic mutations were tested, under different conditions including two electrophoretic apparatus (PhastSystem(TM and GenePhor(TM, Amersham Biosciences, different polyacrylamide gel concentrations, run temperatures and denaturing agents, and entire and restriction enzyme cut fragments. One hundred percent of sensitivity was achieved with four of the new fragments formed, using the PhastSystem(TM and 20% gels at 15ºC, without the need of restriction enzymes. This nonradioactive PCR-SSCP approach showed to be simple, rapid and sensitive, reducing the costs involved in frequent sequencing repetitions and increasing the reliability of the results. It can be especially useful for laboratories which do not have an automated sequencer.

  18. A cross docking pipeline for improving pose prediction and virtual screening performance

    Science.gov (United States)

    Kumar, Ashutosh; Zhang, Kam Y. J.

    2018-01-01

    Pose prediction and virtual screening performance of a molecular docking method depend on the choice of protein structures used for docking. Multiple structures for a target protein are often used to take into account the receptor flexibility and problems associated with a single receptor structure. However, the use of multiple receptor structures is computationally expensive when docking a large library of small molecules. Here, we propose a new cross-docking pipeline suitable to dock a large library of molecules while taking advantage of multiple target protein structures. Our method involves the selection of a suitable receptor for each ligand in a screening library utilizing ligand 3D shape similarity with crystallographic ligands. We have prospectively evaluated our method in D3R Grand Challenge 2 and demonstrated that our cross-docking pipeline can achieve similar or better performance than using either single or multiple-receptor structures. Moreover, our method displayed not only decent pose prediction performance but also better virtual screening performance over several other methods.

  19. Direct detection of single-nucleotide polymorphisms in bacterial DNA by SNPtrap

    DEFF Research Database (Denmark)

    Grønlund, Hugo Ahlm; Moen, Birgitte; Hoorfar, Jeffrey

    2011-01-01

    A major challenge with single-nucleotide polymorphism (SNP) fingerprinting of bacteria and higher organisms is the combination of genome-wide screenings with the potential of multiplexing and accurate SNP detection. Single-nucleotide extension by the minisequencing principle represents a technolo...

  20. Breast screening policy: Are we heading in the right direction?

    International Nuclear Information System (INIS)

    Evans, A.; Whelehan, P.

    2011-01-01

    There is a large body of evidence supporting 2-yearly screening of women aged 50-69 years. There is good evidence for a mortality reduction from mammographic screening in women aged 40 to 49 years but a 1-year interval is required. The lack of specificity of screening in young women does remain a problem. There is no evidence to suggest that a single screen between the ages of 47 and 50 years within a programme screening at 3-year intervals will reduce mortality; the trials showing a mortality benefit in women in their 40s included multiple screening episodes and shorter screening intervals. There is no randomized, controlled trial evidence to support screening in women aged above 70 years and screening this age group will cause greater harm than in younger women through higher rates of over-diagnosis and consequent over-treatment. The randomized phase of the screening age extension, which at the moment is planned to last only 6 years, should not be immediately followed by general implementation of the policy. Only if and when additional mortality reductions and an acceptable balance between benefit and harms are shown to be achieved by the extra screens should the 2007 Cancer Reform Strategy policy on age extension be implemented. Resources saved by delaying or abandoning the roll-out of the age extension could potentially be redirected towards reducing the current 3 year screening interval to 2 years in women aged 50-69 years. However, reducing the screening interval to 2 years for women aged 50-69 years would require significantly more screening invitations and resources than the proposed age extension.

  1. Breast screening policy: Are we heading in the right direction?

    Energy Technology Data Exchange (ETDEWEB)

    Evans, A., E-mail: a.z.evans@dundee.ac.uk [Dundee Cancer Centre, Ninewells Hospital and Medical School, University of Dundee, Dundee (United Kingdom); Whelehan, P. [Dundee Cancer Centre, Ninewells Hospital and Medical School, University of Dundee, Dundee (United Kingdom)

    2011-10-15

    There is a large body of evidence supporting 2-yearly screening of women aged 50-69 years. There is good evidence for a mortality reduction from mammographic screening in women aged 40 to 49 years but a 1-year interval is required. The lack of specificity of screening in young women does remain a problem. There is no evidence to suggest that a single screen between the ages of 47 and 50 years within a programme screening at 3-year intervals will reduce mortality; the trials showing a mortality benefit in women in their 40s included multiple screening episodes and shorter screening intervals. There is no randomized, controlled trial evidence to support screening in women aged above 70 years and screening this age group will cause greater harm than in younger women through higher rates of over-diagnosis and consequent over-treatment. The randomized phase of the screening age extension, which at the moment is planned to last only 6 years, should not be immediately followed by general implementation of the policy. Only if and when additional mortality reductions and an acceptable balance between benefit and harms are shown to be achieved by the extra screens should the 2007 Cancer Reform Strategy policy on age extension be implemented. Resources saved by delaying or abandoning the roll-out of the age extension could potentially be redirected towards reducing the current 3 year screening interval to 2 years in women aged 50-69 years. However, reducing the screening interval to 2 years for women aged 50-69 years would require significantly more screening invitations and resources than the proposed age extension.

  2. CRISPR-FOCUS: A web server for designing focused CRISPR screening experiments

    OpenAIRE

    Cao, Qingyi; Ma, Jian; Chen, Chen-Hao; Xu, Han; Chen, Zhi; Li, Wei; Liu, X. Shirley

    2017-01-01

    The recently developed CRISPR screen technology, based on the CRISPR/Cas9 genome editing system, enables genome-wide interrogation of gene functions in an efficient and cost-effective manner. Although many computational algorithms and web servers have been developed to design single-guide RNAs (sgRNAs) with high specificity and efficiency, algorithms specifically designed for conducting CRISPR screens are still lacking. Here we present CRISPR-FOCUS, a web-based platform to search and prioriti...

  3. Demonstration of acoustic source localization in air using single pixel compressive imaging

    Science.gov (United States)

    Rogers, Jeffrey S.; Rohde, Charles A.; Guild, Matthew D.; Naify, Christina J.; Martin, Theodore P.; Orris, Gregory J.

    2017-12-01

    Acoustic source localization often relies on large sensor arrays that can be electronically complex and have large data storage requirements to process element level data. Recently, the concept of a single-pixel-imager has garnered interest in the electromagnetics literature due to its ability to form high quality images with a single receiver paired with shaped aperture screens that allow for the collection of spatially orthogonal measurements. Here, we present a method for creating an acoustic analog to the single-pixel-imager found in electromagnetics for the purpose of source localization. Additionally, diffraction is considered to account for screen openings comparable to the acoustic wavelength. A diffraction model is presented and incorporated into the single pixel framework. In this paper, we explore the possibility of applying single pixel localization to acoustic measurements. The method is experimentally validated with laboratory measurements made in an air waveguide.

  4. Nutrition screening tools: does one size fit all? A systematic review of screening tools for the hospital setting.

    Science.gov (United States)

    van Bokhorst-de van der Schueren, Marian A E; Guaitoli, Patrícia Realino; Jansma, Elise P; de Vet, Henrica C W

    2014-02-01

    Numerous nutrition screening tools for the hospital setting have been developed. The aim of this systematic review is to study construct or criterion validity and predictive validity of nutrition screening tools for the general hospital setting. A systematic review of English, French, German, Spanish, Portuguese and Dutch articles identified via MEDLINE, Cinahl and EMBASE (from inception to the 2nd of February 2012). Additional studies were identified by checking reference lists of identified manuscripts. Search terms included key words for malnutrition, screening or assessment instruments, and terms for hospital setting and adults. Data were extracted independently by 2 authors. Only studies expressing the (construct, criterion or predictive) validity of a tool were included. 83 studies (32 screening tools) were identified: 42 studies on construct or criterion validity versus a reference method and 51 studies on predictive validity on outcome (i.e. length of stay, mortality or complications). None of the tools performed consistently well to establish the patients' nutritional status. For the elderly, MNA performed fair to good, for the adults MUST performed fair to good. SGA, NRS-2002 and MUST performed well in predicting outcome in approximately half of the studies reviewed in adults, but not in older patients. Not one single screening or assessment tool is capable of adequate nutrition screening as well as predicting poor nutrition related outcome. Development of new tools seems redundant and will most probably not lead to new insights. New studies comparing different tools within one patient population are required. Copyright © 2013 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  5. Screening individual hybridomas by microengraving to discover monoclonal antibodies

    Science.gov (United States)

    Ogunniyi, Adebola O; Story, Craig M; Papa, Eliseo; Guillen, Eduardo; Love, J Christopher

    2014-01-01

    The demand for monoclonal antibodies (mAbs) in biomedical research is significant, but the current methodologies used to discover them are both lengthy and costly. Consequently, the diversity of antibodies available for any particular antigen remains limited. Microengraving is a soft lithographic technique that provides a rapid and efficient alternative for discovering new mAbs. This protocol describes how to use microengraving to screen mouse hybridomas to establish new cell lines producing unique mAbs. Single cells from a polyclonal population are isolated into an array of microscale wells (~105 cells per screen). The array is then used to print a protein microarray, where each element contains the antibodies captured from individual wells. The antibodies on the microarray are screened with antigens of interest, and mapped to the corresponding cells, which are then recovered from their microwells by micromanipulation. Screening and retrieval require approximately 1–3 d (9–12 d including the steps for preparing arrays of microwells). PMID:19528952

  6. Advances in Predictive Toxicology for Discovery Safety through High Content Screening.

    Science.gov (United States)

    Persson, Mikael; Hornberg, Jorrit J

    2016-12-19

    High content screening enables parallel acquisition of multiple molecular and cellular readouts. In particular the predictive toxicology field has progressed from the advances in high content screening, as more refined end points that report on cellular health can be studied in combination, at the single cell level, and in relatively high throughput. Here, we discuss how high content screening has become an essential tool for Discovery Safety, the discipline that integrates safety and toxicology in the drug discovery process to identify and mitigate safety concerns with the aim to design drug candidates with a superior safety profile. In addition to customized mechanistic assays to evaluate target safety, routine screening assays can be applied to identify risk factors for frequently occurring organ toxicities. We discuss the current state of high content screening assays for hepatotoxicity, cardiotoxicity, neurotoxicity, nephrotoxicity, and genotoxicity, including recent developments and current advances.

  7. Laser micromachining of screen-printed graphene for forming electrode structures

    International Nuclear Information System (INIS)

    Chang, Tien-Li; Chen, Zhao-Chi; Tseng, Shih-Feng

    2016-01-01

    Highlights: • Homogeneous graphene films were prepared by the screen-printing process. • Optimal single-line ablation was performed by ultraviolet nanosecond laser pulses. • Influence of ablation parameters on graphene/glass substrate was clarified. • Electrical measurements of ablated graphene-based device can be investigated. - Abstract: There has been increasing research interest in electronic applications of graphene-based devices fabricated using electrode patterning techniques. This study presents a laser ablation technique along with a screen printing process for fabricating graphene patterns on a glass substrate. First, homogeneous multilayer films on the glass substrate are coated with graphene ink by using the screen printing process. Subsequently, optimal ablation was performed using an ultraviolet nanosecond laser, and the effective number of pulses decreased with an increase in the scanning speed and a decrease in the overlapping rate. Here, the pulsed overlap of a laser spot was determined to be approximately 90% for 75 pulses at a scanning speed of 250 mm/s. Experimental results showed continuous single-line ablation along the laser scanning path in the graphene films. Furthermore, linear current–voltage (I–V) curves showed the multilayer graphene characteristics of ablated devices for forming electrode structures.

  8. Comprehensive preimplantation genetic screening and sperm deoxyribonucleic acid fragmentation from three males carrying balanced chromosome rearrangements.

    Science.gov (United States)

    Ramos, Laia; Daina, Gemma; Del Rey, Javier; Ribas-Maynou, Jordi; Fernández-Encinas, Alba; Martinez-Passarell, Olga; Boada, Montserrat; Benet, Jordi; Navarro, Joaquima

    2015-09-01

    To assess whether preimplantation genetic screening can successfully identify cytogenetically normal embryos in couples carrying balanced chromosome rearrangements in addition to increased sperm DNA fragmentation. Comprehensive preimplantation genetic screening was performed on three couples carrying chromosome rearrangements. Sperm DNA fragmentation was assessed for each patient. Academic center. One couple with the male partner carrying a chromosome 2 pericentric inversion and two couples with the male partners carrying a Robertsonian translocation (13:14 and 14:21, respectively). A single blastomere from each of the 18 cleavage-stage embryos obtained was analysed by metaphase comparative genomic hybridization. Single- and double-strand sperm DNA fragmentation was determined by the alkaline and neutral Comet assays. Single- and double-strand sperm DNA fragmentation values and incidence of chromosome imbalances in the blastomeres were analyzed. The obtained values of single-strand sperm DNA fragmentation were between 47% and 59%, and the double-strand sperm DNA fragmentation values were between 43% and 54%. No euploid embryos were observed in the couple showing the highest single-strand sperm DNA fragmentation. However, euploid embryos were observed in the other two couples: embryo transfer was performed, and pregnancy was achieved by the couple showing the lowest sperm DNA fragmentation values. Preimplantation genetic screening enables the detection of euploid embryos in couples affected by balanced chromosome rearrangements and increased sperm DNA fragmentation. Even though sperm DNA fragmentation may potentially have clinical consequences on fertility, comprehensive preimplantation genetic screening allows for the identification and transfer of euploid embryos. Copyright © 2015. Published by Elsevier Inc.

  9. Depression Screening

    Science.gov (United States)

    ... Depression Screening Substance Abuse Screening Alcohol Use Screening Depression Screening (PHQ-9) - Instructions The following questions are ... this tool, there is also text-only version . Depression Screening - Manual Instructions The following questions are a ...

  10. Effectiveness and cost-effectiveness of double reading in digital mammography screening: A systematic review and meta-analysis.

    Science.gov (United States)

    Posso, Margarita; Puig, Teresa; Carles, Misericòrdia; Rué, Montserrat; Canelo-Aybar, Carlos; Bonfill, Xavier

    2017-11-01

    Double reading is the strategy of choice for mammogram interpretation in screening programmes. It remains, however, unknown whether double reading is still the strategy of choice in the context of digital mammography. Our aim was to determine the effectiveness and cost-effectiveness of double reading versus single reading of digital mammograms in screening programmes. We performed a systematic review by searching the PubMed, Embase, and Cochrane Library databases up to April 2017. We used the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies) tool and CHEERS (Consolidated Health Economic Evaluation Reporting Standards) checklist to assess the methodological quality of the diagnostic studies and economic evaluations, respectively. A proportion's meta-analysis approach, 95% Confidence Intervals (95% CI) and test of heterogeneity (P values) were used for pooled results. Costs are expressed US$ PPP (United States Dollar purchasing power parities). The PROSPERO ID of this Systematic Review's protocol is CRD42014013804. Of 1473 potentially relevant hits, four high-quality studies were included. The pooled cancer detection rate of double reading was 6.01 per 1000 screens (CI: 4.47‰-7.77‰), and it was 5.65 per 1000 screens (CI: 3.95‰-7.65‰) for single reading (P=0.76). The pooled proportion of false-positives of double reading was 47.03 per 1000 screens (CI: 39.13‰-55.62‰) and it was 40.60 per 1000 screens (CI: 38.58‰-42.67‰) for single reading (P=0.12). One study reported, for double reading, an ICER (Incremental Cost-Effectiveness Ratio) of 16,684 Euros (24,717 US$ PPP; 2015 value) per detected cancer. Single reading+CAD (computer-aided-detection) was cost-effective in Japan. The evidence of benefit for double reading compared to single reading for digital mammography interpretation is scarce. Double reading seems to increase operational costs, have a not significantly higher false-positive rate, and a similar cancer detection rate. Copyright

  11. Correction of Microplate Data from High-Throughput Screening.

    Science.gov (United States)

    Wang, Yuhong; Huang, Ruili

    2016-01-01

    High-throughput screening (HTS) makes it possible to collect cellular response data from a large number of cell lines and small molecules in a timely and cost-effective manner. The errors and noises in the microplate-formatted data from HTS have unique characteristics, and they can be generally grouped into three categories: run-wise (temporal, multiple plates), plate-wise (background pattern, single plate), and well-wise (single well). In this chapter, we describe a systematic solution for identifying and correcting such errors and noises, mainly basing on pattern recognition and digital signal processing technologies.

  12. Alignment of breast cancer screening guidelines, accountability metrics, and practice patterns.

    Science.gov (United States)

    Onega, Tracy; Haas, Jennifer S; Bitton, Asaf; Brackett, Charles; Weiss, Julie; Goodrich, Martha; Harris, Kimberly; Pyle, Steve; Tosteson, Anna N A

    2017-01-01

    Breast cancer screening guidelines and metrics are inconsistent with each other and may differ from breast screening practice patterns in primary care. This study measured breast cancer screening practice patterns in relation to common evidence-based guidelines and accountability metrics. Cohort study using primary data collected from a regional breast cancer screening research network between 2011 and 2014. Using information on women aged 30 to 89 years within 21 primary care practices of 2 large integrated health systems in New England, we measured the proportion of women screened overall and by age using 2 screening definition categories: any mammogram and screening mammogram. Of the 81,352 women in our cohort, 54,903 (67.5%) had at least 1 mammogram during the time period, 48,314 (59.4%) had a screening mammogram. Women aged 50 to 69 years were the highest proportion screened (82.4% any mammogram, 75% screening indication); 72.6% of women at age 40 had a screening mammogram with a median of 70% (range = 54.3%-84.8%) among the practices. Of women aged at least 75 years, 63.3% had a screening mammogram, with the median of 63.9% (range = 37.2%-78.3%) among the practices. Of women who had 2 or more mammograms, 79.5% were screened annually. Primary care practice patterns for breast cancer screening are not well aligned with some evidence-based guidelines and accountability metrics. Metrics and incentives should be designed with more uniformity and should also include shared decision making when the evidence does not clearly support one single conclusion.

  13. Bead-based screening in chemical biology and drug discovery

    DEFF Research Database (Denmark)

    Komnatnyy, Vitaly V.; Nielsen, Thomas Eiland; Qvortrup, Katrine

    2018-01-01

    libraries for early drug discovery. Among the various library forms, the one-bead-one-compound (OBOC) library, where each bead carries many copies of a single compound, holds the greatest potential for the rapid identification of novel hits against emerging drug targets. However, this potential has not yet...... been fully realized due to a number of technical obstacles. In this feature article, we review the progress that has been made towards bead-based library screening and applications to the discovery of bioactive compounds. We identify the key challenges of this approach and highlight key steps needed......High-throughput screening is an important component of the drug discovery process. The screening of libraries containing hundreds of thousands of compounds requires assays amanable to miniaturisation and automization. Combinatorial chemistry holds a unique promise to deliver structural diverse...

  14. Adenoma detection in patients undergoing a comprehensive colonoscopy screening

    International Nuclear Information System (INIS)

    Raju, Gottumukkala S; Vadyala, Vikram; Slack, Rebecca; Krishna, Somashekar G; Ross, William A; Lynch, Patrick M; Bresalier, Robert S; Hawk, Ernest; Stroehlein, John R

    2013-01-01

    Measures shown to improve the adenoma detection during colonoscopy (excellent bowel preparation, cecal intubation, cap fitted colonoscope to examine behind folds, patient position change to optimize colon distention, trained endoscopy team focusing on detection of subtle flat lesions, and incorporation of optimum endoscopic examination with adequate withdrawal time) are applicable to clinical practice and, if incorporated are projected to facilitate comprehensive colonoscopy screening program for colon cancer prevention. To determine adenoma and serrated polyp detection rate under conditions designed to optimize quality parameters for comprehensive screening colonoscopy. Retrospective analysis of data obtained from a comprehensive colon cancer screening program designed to optimize quality parameters. Academic medical center. Three hundred and forty-three patients between the ages of 50 years and 75 years who underwent first screening colonoscopy between 2009 and 2011 among 535 consecutive patients undergoing colonoscopy. Comprehensive colonoscopy screening program was utilized to screen all patients. Cecal intubation was successful in 98.8% of patients. The Boston Bowel Preparation Scale for quality of colonoscopy was 8.97 (95% confidence interval [CI]; 8.94, 9.00). The rate of adenoma detection was 60% and serrated lesion (defined as serrated adenomas or hyperplastic polyps proximal to the splenic flexure) detection was 23%. The rate of precancerous lesion detection (adenomas and serrated lesions) was 66%. The mean number of adenomas per screening procedure was 1.4 (1.2, 1.6) and the mean number of precancerous lesions (adenomas or serrated lesions) per screening procedure was 1.6 (1.4, 1.8). Retrospective study and single endoscopist experience. A comprehensive colonoscopy screening program results in high-quality screening with high detection of adenomas, advanced adenomas, serrated adenomas, and multiple adenomas

  15. [Generalized neonatal screening based on laboratory tests].

    Science.gov (United States)

    Ardaillou, Raymond; Le Gall, Jean-Yves

    2006-11-01

    diseases in a single run. In addition to issues of cost and organization, any increase in the number of screened diseases will raise ethical problems, such as how to inform parents of an incurable disease, a late-onset disease, or an entirely asymptomatic disorder. It is unanimously agreed that only Mendelian diseases should be screened for (excluding genetic polymorphisms). Analysis of the present situation suggests the following changes:--guidelines for choosing new diseases for neonatal screening should be updated;--all new screening programs should be tested locally before nationwide implementation;--an evaluation committee of paediatricians and epidemiologists should be created, and the children's long-term outcome should be studied;--the conditions in which heterozygous carriers are informed after familial investigations need to be precisely defined;--blood samples should be banked for epidemiological studies.

  16. Single Cell Assay for Analyzing Single Cell Exosome and Endocrine Secretion and Cancer Markers

    Science.gov (United States)

    Chiu, Yu-Jui

    To understand the inhomogeneity of cells in biological systems, there is a growing demand for the capability to characterize the properties of individual single cells. Since single cell studies require continuous monitoring of the cell behaviors instead of a snapshot test at a single time point, an effective single-cell assay that can support time lapsed studies in a high throughput manner is desired. Most currently available single-cell technologies cannot provide proper environments to sustain cell growth and cannot provide, for appropriate cell types, proliferation of single cells and convenient, non-invasive tests of single cell behaviors from molecular markers. In this dissertation, I present a highly versatile single-cell assay that can accommodate different cellular types, enable easy and efficient single cell loading and culturing, and be suitable for the study of effects of in-vitro environmental factors in combination with drug screening. The salient features of the assay are the non-invasive collection and surveying of single cell secretions at different time points and massively parallel translocation of single cells by user defined criteria, producing very high compatibility to the downstream process such as single cell qPCR and sequencing. Above all, the acquired information is quantitative -- for example, one of the studies is measured by the number of exosomes each single cell secretes for a given time period. Therefore, our single-cell assay provides a convenient, low-cost, and enabling tool for quantitative, time lapsed studies of single cell properties.

  17. Adherence to the cervical cancer screening program in women living with HIV in Denmark

    DEFF Research Database (Denmark)

    Thorsteinsson, Kristina; Ladelund, Steen; Jensen-Fangel, Søren

    2014-01-01

    BACKGROUND: Women living with HIV (WLWH) are at increased risk of invasive cervical cancer (ICC). International HIV guidelines suggest cervical screening twice the first year after HIV diagnosis and thereafter annually. Adherence to the HIV cervical screening program in Denmark is unknown. METHODS......: We studied women from a population-based, nationwide HIV cohort in Denmark and a cohort of age-matched females from the general population. Screening behaviour was assessed from 1999-2010. Adjusted odds ratios (OR's) for screening attendance in the two cohorts and potential predictors of attendance....... CONCLUSIONS: The majority of WLWH do not follow the HIV guidelines for cervical screening. We support the idea of cytology as part of an annual review and integration of HIV care and cervical screening in a single clinic setting....

  18. Approaches to virtual screening and screening library selection.

    Science.gov (United States)

    Wildman, Scott A

    2013-01-01

    The ease of access to virtual screening (VS) software in recent years has resulted in a large increase in literature reports. Over 300 publications in the last year report the use of virtual screening techniques to identify new chemical matter or present the development of new virtual screening techniques. The increased use is accompanied by a corresponding increase in misuse and misinterpretation of virtual screening results. This review aims to identify many of the common difficulties associated with virtual screening and allow researchers to better assess the reliability of their virtual screening effort.

  19. Preimplantation genetic diagnosis and screening by array comparative genomic hybridisation: experience of more than 100 cases in a single centre.

    Science.gov (United States)

    Chow, J Fc; Yeung, W Sb; Lee, V Cy; Lau, E Yl; Ho, P C; Ng, E Hy

    2017-04-01

    Preimplantation genetic screening has been proposed to improve the in-vitro fertilisation outcome by screening for aneuploid embryos or blastocysts. This study aimed to report the outcome of 133 cycles of preimplantation genetic diagnosis and screening by array comparative genomic hybridisation. This study of case series was conducted in a tertiary assisted reproductive centre in Hong Kong. Patients who underwent preimplantation genetic diagnosis for chromosomal abnormalities or preimplantation genetic screening between 1 April 2012 and 30 June 2015 were included. They underwent in-vitro fertilisation and intracytoplasmic sperm injection. An embryo biopsy was performed on day-3 embryos and the blastomere was subject to array comparative genomic hybridisation. Embryos with normal copy numbers were replaced. The ongoing pregnancy rate, implantation rate, and miscarriage rate were studied. During the study period, 133 cycles of preimplantation genetic diagnosis for chromosomal abnormalities or preimplantation genetic screening were initiated in 94 patients. Overall, 112 cycles proceeded to embryo biopsy and 65 cycles had embryo transfer. The ongoing pregnancy rate per transfer cycle after preimplantation genetic screening was 50.0% and that after preimplantation genetic diagnosis was 34.9%. The implantation rates after preimplantation genetic screening and diagnosis were 45.7% and 41.1%, respectively and the miscarriage rates were 8.3% and 28.6%, respectively. There were 26 frozen-thawed embryo transfer cycles, in which vitrified and biopsied genetically transferrable embryos were replaced, resulting in an ongoing pregnancy rate of 36.4% in the screening group and 60.0% in the diagnosis group. The clinical outcomes of preimplantation genetic diagnosis and screening using comparative genomic hybridisation in our unit were comparable to those reported internationally. Genetically transferrable embryos replaced in a natural cycle may improve the ongoing pregnancy rate

  20. BACTEC MGIT 960 TM system for screening of Mycobacterium ...

    African Journals Online (AJOL)

    This study was aimed to evaluate the recent technique (BACTEC MGIT 960 TM system) for screening of Mycobacterium tuberculosis complex among cattle in Egypt. From the 1180 cattle examined in three different Governorates (El-Sharkia, El-Gharbia and El-Monefeia) by single intradermal tuberculin test, 29 animals ...

  1. Database for High Throughput Screening Hits (dHITS): a simple tool to retrieve gene specific phenotypes from systematic screens done in yeast.

    Science.gov (United States)

    Chuartzman, Silvia G; Schuldiner, Maya

    2018-03-25

    In the last decade several collections of Saccharomyces cerevisiae yeast strains have been created. In these collections every gene is modified in a similar manner such as by a deletion or the addition of a protein tag. Such libraries have enabled a diversity of systematic screens, giving rise to large amounts of information regarding gene functions. However, often papers describing such screens focus on a single gene or a small set of genes and all other loci affecting the phenotype of choice ('hits') are only mentioned in tables that are provided as supplementary material and are often hard to retrieve or search. To help unify and make such data accessible, we have created a Database of High Throughput Screening Hits (dHITS). The dHITS database enables information to be obtained about screens in which genes of interest were found as well as the other genes that came up in that screen - all in a readily accessible and downloadable format. The ability to query large lists of genes at the same time provides a platform to easily analyse hits obtained from transcriptional analyses or other screens. We hope that this platform will serve as a tool to facilitate investigation of protein functions to the yeast community. © 2018 The Authors Yeast Published by John Wiley & Sons Ltd.

  2. Ovipositor setation in oldest insects (Insecta: Archaeognatha) revealed by SEM and He-ion microscopy.

    Science.gov (United States)

    Matushkina, Nataliia A

    2017-10-01

    Archaeognatha represent the oldest living lineage of true insects (=Ectognatha), which are remarkable, among others, for plesiomorphic genital morphology and complicated mating behaviour. I used scanning electron microscopy and He-ion microscopy to examine the ovipositor morphology of seven species, in order to describe the cuticle microsculpture. The species studied are characterised by different types of the ovipositor setation pattern, which are considered an important taxonomic feature for Archaeognatha. The common and well discernible elements of ovipositor setation in Archaeognatha are: (1) non-articulated terminal seta, (2) grooved type I basiconic sensillum with apical pore, (3) multiporous type II basiconic sensillum, (4) articulated setae of different length. Coeloconica-like sensilla and campaniform sensilla demonstrate a variety of transient morphology. Results of this study provide morphological evidence of presence of olfactory receptors on the ovipositor in Archaeognatha. The possible functions of the ovipositor setation in Archaeognatha are discussed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Reader practice in mammography screen reporting in Australia

    International Nuclear Information System (INIS)

    Reed, W.; Poulos, A.; Brennan, P.

    2009-01-01

    Full text: Reader variability is a problem in mammography image reporting and compromises the efficacy of screening programmes. The purpose of this exploratory study was to survey reader practice in reporting screening mammograms in Australia to identify aspects of practice that warrant further investigation. Mammography reporting practice and influences on concentration and attention were investigated by using an original questionnaire distributed to screen readers in Australia. A response rate of 71% (83 out of 117) was achieved. Demographic data indicated that the majority of readers were over 46 years of age (73%), have been reporting on screening mammograms for over 10 years (61%), take less than 1 min to report upon a screening mammogram examination (66%), report up to 200 examinations in a single session (83%) and take up to 2 h to report one session (61%). A majority report on more than 5000 examinations annually (66%); 93% of participants regard their search strategy as systematic, 87% agreed that their concentration can vary throughout a session, 64% agreed that the relatively low number of positives can lead to lapses in concentration and attention and almost all (94%) participants agreed that methods to maximise concentration should be explored. Participants identified a range of influences on concentration within their working environment including volume of images reported in one session, image types and aspects of the physical environment. This study has provided important evidence of the need to investigate adverse influences on concentration during mammography screen reporting

  4. Oral cancer screening: serum Raman spectroscopic approach

    Science.gov (United States)

    Sahu, Aditi K.; Dhoot, Suyash; Singh, Amandeep; Sawant, Sharada S.; Nandakumar, Nikhila; Talathi-Desai, Sneha; Garud, Mandavi; Pagare, Sandeep; Srivastava, Sanjeeva; Nair, Sudhir; Chaturvedi, Pankaj; Murali Krishna, C.

    2015-11-01

    Serum Raman spectroscopy (RS) has previously shown potential in oral cancer diagnosis and recurrence prediction. To evaluate the potential of serum RS in oral cancer screening, premalignant and cancer-specific detection was explored in the present study using 328 subjects belonging to healthy controls, premalignant, disease controls, and oral cancer groups. Spectra were acquired using a Raman microprobe. Spectral findings suggest changes in amino acids, lipids, protein, DNA, and β-carotene across the groups. A patient-wise approach was employed for data analysis using principal component linear discriminant analysis. In the first step, the classification among premalignant, disease control (nonoral cancer), oral cancer, and normal samples was evaluated in binary classification models. Thereafter, two screening-friendly classification approaches were explored to further evaluate the clinical utility of serum RS: a single four-group model and normal versus abnormal followed by determining the type of abnormality model. Results demonstrate the feasibility of premalignant and specific cancer detection. The normal versus abnormal model yields better sensitivity and specificity rates of 64 and 80% these rates are comparable to standard screening approaches. Prospectively, as the current screening procedure of visual inspection is useful mainly for high-risk populations, serum RS may serve as a useful adjunct for early and specific detection of oral precancers and cancer.

  5. The effect of aluminium screen on the quality of radiographic image using x-radiation

    International Nuclear Information System (INIS)

    Azali Muhammad; Azhar Azmi; Mohd Soot Ahmad; Hafizul Abd Ghani

    2002-01-01

    The effect of different thickness of aluminium screen on the quality of radiographic image and the exposure time have been studied. The specimen used was based on the steel step wedge having thickness ranging from minimum 10 mm up to maximum 15 mm. The specimen was exposed to 100 kV up to 190 kV x-radiation by using single wall single image (SWSI) radiographic technique. The radiographic film D7 used in this study, which sandwiched with metallic screen made of aluminium, or lead was inserted into flexible cassette. The quality of the radiograph was then evaluated by observing the appearance of DIN wire type image quality indicator (IQI) 10ISO16 and the density difference (ΔD) of two adjacent steps on the radiograph, i.e. the subject contrast. The result shows that at a certain applied voltage (kV), the used of different thickness of aluminium screens give significant effect on the Δ D. Besides that the radiographic image quality in term of visibility of the smallest wire of IQI on radiograph also increases with decreasing kV for all types of aluminium screen. It is observed as well the effect of thickness of aluminium screen on subject contrast depends on the kV, i.e. for kV ranging from 100 up to 190 kV the subject contrast increases with increasing thickness of aluminium screen. The comparison of these results with radiograph using lead screen was also presented in this paper. (Author)

  6. Progress report on INEL full flow drag screen

    International Nuclear Information System (INIS)

    Arave, A.E.; Colson, J.B.; Fincke, J.R.

    1977-01-01

    The objective in developing a full flow drag screen is to obtain a total momentum flux measurement which when combined with a suitable independent velocity or density measurement will yield a total mass flux. The major design considerations are predicated by the fact that an accurate momentum flux measurement must be made over a wide range of flow conditions. The device should exhibit a constant calibration regardless of Reynolds number, void fraction, slip ratio, or flow regime. The dynamics of drag devices are well understood in single-phase flows. This is not true for two-phase flows. The present development program is directed toward gaining an understanding of the dynamics of drag devices which sample the total area of a pipe in two-phase flow and developing a method for deducing mass flow rate using such a device. Various geometric arrangements are to be investigated. Testing to date has shown excellent results using a round wire mesh screen in the Semiscale air/water loop. Future air/water testing will include perforated plates and wire meshes with both rectangular and diamond shaped cross sections. Analytical models of the hydrodynamics of the drag screen as well as the associated density or velocity measuring device are being used to select the optimum configuration. Alternate force sensing methods are also being considered. These include single and multiple transducer arrangements. Multistage springs and pressure drop across the body are to be evaluated for extending the dynamic range of the drag body

  7. Basic elements for breast screening programs for Rwanda

    International Nuclear Information System (INIS)

    Abenanye, Emmanuel

    2015-02-01

    Mammography refers to the X-ray examination of the human breast, and is considered the single most important diagnostic tool in the early detection of breast cancer, which is by far the most common cancer among women. There is good evidence from clinical trials, that mammographic screening can reduce the breast cancer mortality with about 30%. The side effects include a small and age related risk of carcinogenesis due to the exposure of the glandular tissues in the breast to ionizing radiation. As for all X-ray examinations, and of special importance when investigating large populations of asymptomatic women, the relationship between radiation risk and diagnostic accuracy in mammography must be optimized. The overall objective of this thesis was to investigate and improve methods for average glandular dose (AGD) and image quality evaluation in mammography and provide some practical guidance. To assess the behavioral factors influencing breast screening the best set up of the mammography unit as well as equipment construction and the skills of people operating the machines in terms of the radiation protection screening programs. There has been doubts about the efficiency of so called service screening, i.e. routine screening programs (Sjonell and Stahle, 1999), but there is evidence suggesting a reduction of breast cancer mortality similar to that observed in the randomised trials (Duffy et al. 2002). However no study has been carried out in Rwanda of this nature to see what are the basic breast screening elements and behavioral elements that influence it. Therefore, the factors that influence women's mammography screening behavior is an important issue to be uncovered, in order to facilitate the understanding of such a behavior. This report sets out to investigate the factors that influence participation in mammography screening in Rwanda. Such an investigation aims to raise the awareness of health care providers of the factors that influence Rwanda's women

  8. Prospective Assessment of Virtual Screening Heuristics Derived Using a Novel Fusion Score.

    Science.gov (United States)

    Pertusi, Dante A; O'Donnell, Gregory; Homsher, Michelle F; Solly, Kelli; Patel, Amita; Stahler, Shannon L; Riley, Daniel; Finley, Michael F; Finger, Eleftheria N; Adam, Gregory C; Meng, Juncai; Bell, David J; Zuck, Paul D; Hudak, Edward M; Weber, Michael J; Nothstein, Jennifer E; Locco, Louis; Quinn, Carissa; Amoss, Adam; Squadroni, Brian; Hartnett, Michelle; Heo, Mee Ra; White, Tara; May, S Alex; Boots, Evelyn; Roberts, Kenneth; Cocchiarella, Patrick; Wolicki, Alex; Kreamer, Anthony; Kutchukian, Peter S; Wassermann, Anne Mai; Uebele, Victor N; Glick, Meir; Rusinko, Andrew; Culberson, J Christopher

    2017-09-01

    High-throughput screening (HTS) is a widespread method in early drug discovery for identifying promising chemical matter that modulates a target or phenotype of interest. Because HTS campaigns involve screening millions of compounds, it is often desirable to initiate screening with a subset of the full collection. Subsequently, virtual screening methods prioritize likely active compounds in the remaining collection in an iterative process. With this approach, orthogonal virtual screening methods are often applied, necessitating the prioritization of hits from different approaches. Here, we introduce a novel method of fusing these prioritizations and benchmark it prospectively on 17 screening campaigns using virtual screening methods in three descriptor spaces. We found that the fusion approach retrieves 15% to 65% more active chemical series than any single machine-learning method and that appropriately weighting contributions of similarity and machine-learning scoring techniques can increase enrichment by 1% to 19%. We also use fusion scoring to evaluate the tradeoff between screening more chemical matter initially in lieu of replicate samples to prevent false-positives and find that the former option leads to the retrieval of more active chemical series. These results represent guidelines that can increase the rate of identification of promising active compounds in future iterative screens.

  9. Primary care colorectal cancer screening correlates with breast cancer screening: implications for colorectal cancer screening improvement interventions.

    Science.gov (United States)

    Weiss, Jennifer M; Pandhi, Nancy; Kraft, Sally; Potvien, Aaron; Carayon, Pascale; Smith, Maureen A

    2018-04-25

    National colorectal cancer (CRC) screening rates have plateaued. To optimize interventions targeting those unscreened, a better understanding is needed of how this preventive service fits in with multiple preventive and chronic care needs managed by primary care providers (PCPs). This study examines whether PCP practices of other preventive and chronic care needs correlate with CRC screening. We performed a retrospective cohort study of 90 PCPs and 33,137 CRC screening-eligible patients. Five PCP quality metrics (breast cancer screening, cervical cancer screening, HgbA1c and LDL testing, and blood pressure control) were measured. A baseline correlation test was performed between these metrics and PCP CRC screening rates. Multivariable logistic regression with clustering at the clinic-level estimated odds ratios and 95% confidence intervals for these PCP quality metrics, patient and PCP characteristics, and their relationship to CRC screening. PCP CRC screening rates have a strong correlation with breast cancer screening rates (r = 0.7414, p < 0.001) and a weak correlation with the other quality metrics. In the final adjusted model, the only PCP quality metric that significantly predicted CRC screening was breast cancer screening (OR 1.25; 95% CI 1.11-1.42; p < 0.001). PCP CRC screening rates are highly concordant with breast cancer screening. CRC screening is weakly concordant with cervical cancer screening and chronic disease management metrics. Efforts targeting PCPs to increase CRC screening rates could be bundled with breast cancer screening improvement interventions to increase their impact and success.

  10. More comprehensive discussion of CRC screening associated with higher screening.

    Science.gov (United States)

    Mosen, David M; Feldstein, Adrianne C; Perrin, Nancy A; Rosales, A Gabriella; Smith, David H; Liles, Elizabeth G; Schneider, Jennifer L; Meyers, Ronald E; Elston-Lafata, Jennifer

    2013-04-01

    Examine association of comprehensiveness of colorectal cancer (CRC) screening discussion by primary care physicians (PCPs) with completion of CRC screening. Observational study in Kaiser Permanente Northwest, a group-model health maintenance organization. A total of 883 participants overdue for CRC screening received an automated telephone call (ATC) between April and June 2009 encouraging CRC screening. Between January and March 2010, participants completed a survey on PCPs' discussion of CRC screening and patient beliefs regarding screening. receipt of CRC screening (assessed by electronic medical record [EMR], 9 months after ATC). Primary independent variable: comprehensiveness of CRC screening discussion by PCPs (7-item scale). Secondary independent variables: perceived benefits of screening (4-item scale assessing respondents' agreement with benefits of timely screening) and primary care utilization (EMR; 9 months after ATC). The independent association of variables with CRC screening was assessed with logistic regression. Average scores for comprehensiveness of CRC discussion and perceived benefits were 0.4 (range 0-1) and 4.0 (range 1-5), respectively. A total of 28.2% (n = 249) completed screening, 84% of whom had survey assessments after their screening date. Of screeners, 95.2% completed the fecal immunochemical test. More comprehensive discussion of CRC screening was associated with increased screening (odds ratio [OR] = 1.51, 95% confidence interval [CI] = 1.03-2.21). Higher perceived benefits (OR = 1.46, 95% CI = 1.13-1.90) and 1 or more PCP visits (OR = 5.82, 95% CI = 3.87-8.74) were also associated with increased screening. More comprehensive discussion of CRC screening was independently associated with increased CRC screening. Primary care utilization was even more strongly associated with CRC screening, irrespective of discussion of CRC screening.

  11. Second-screening mammography: One versus two views per breast

    International Nuclear Information System (INIS)

    Ikeda, D.M.; Sickles, E.A.

    1987-01-01

    To compare the advantages of single-versus two-view follow-up screening mammograms, oblique and craniocaudal examinations from 1,000 asymptomatic women who had prior normal baseline studies were reviewed retrospectively, first using only the oblique projection, then using the oblique and craniocaudal views. Single-view readings of dense breasts resulted in considerably more abnormal interpretations then were made with two-view readings. The induced costs from these false-positive readings more than offset the small savings in operating expense of single-view reading. In contradistinction, so few false-positive readings were made in women with fatty breasts (in whom superimposition of dense tissue is not a problem) that savings in operating expense exceeded induced costs

  12. Comparison among single-phase test, automated screening method and GC/MS for the traceability of ketamine in urine

    Directory of Open Access Journals (Sweden)

    Alice Visione

    2016-12-01

    CONCLUSION Following the law indications, ketamine is not searched: this limit does not make the authorities able to apply the penalties expected for road laws violations. The automation is essential to guarantee the reliability of toxicological screening tests, especially to medico-legal significance. This results highlight the absolutely necessity of the execution of the confirmation test, successively to screening analysis.

  13. Alcohol-tolerant mutants of cyanobacterium Synechococcus elongatus PCC 7942 obtained by single-cell mutant screening system.

    Science.gov (United States)

    Arai, Sayuri; Hayashihara, Kayoko; Kanamoto, Yuki; Shimizu, Kazunori; Hirokawa, Yasutaka; Hanai, Taizo; Murakami, Akio; Honda, Hiroyuki

    2017-08-01

    Enhancement of alcohol tolerance in microorganisms is an important strategy for improving bioalcohol productivity. Although cyanobacteria can be used as a promising biocatalyst to produce various alcohols directly from CO 2 , low productivity, and low tolerance against alcohols are the main issues to be resolved. Nevertheless, to date, a mutant with increasing alcohol tolerance has rarely been reported. In this study, we attempted to select isopropanol (IPA)-tolerant mutants of Synechococcus elongatus PCC 7942 using UV-C-induced random mutagenesis, followed by enrichment of the tolerant candidates in medium containing 10 g/L IPA and screening of the cells with a high growth rate in the single cell culture system in liquid medium containing 10 g/L IPA. We successfully acquired the most tolerant strain, SY1043, which maintains the ability to grow in medium containing 30 g/L IPA. The photosynthetic oxygen-evolving activities of SY1043 were almost same in cells after 72 h incubation under light with or without 10 g/L IPA, while the activity of the wild-type was remarkably decreased after the incubation with IPA. SY1043 also showed higher tolerance to ethanol, 1-butanol, isobutanol, and 1-pentanol than the wild type. These results suggest that SY1043 would be a promising candidate to improve alcohol production using cyanobacteria. Biotechnol. Bioeng. 2017;114: 1771-1778. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  14. Role of carotid duplex imaging in carotid screening programmes – an overview

    Directory of Open Access Journals (Sweden)

    Gillard Jonathan H

    2008-07-01

    Full Text Available Abstract Background Stroke is the third most common cause of death in the UK and the largest single cause of severe disability. Each year more than 110,000 people in England suffer from a stroke which costs the National Health Service (NHS over GBP2.8 billion. Thus, it is imperative that patients at risk be screened for underlying carotid artery atherosclerosis. Aim To assess the role of carotid ultrasound in different carotid screening programmes. Methods A literature overview was carried out by using PubMed search engine, to identify different carotid screening programmes that had used ultrasound scan as a screening tool. Results It appears that the carotid ultrasound is an effective method for screening carotid artery disease in community as it effectively predicts the presence of stenosis with high accuracy. There is a need for primary care to recommend high risk patients for regular screening, to reduce stroke and transient ischemic attack (TIA related morbidity and mortality. Conclusion Screening programmes using carotid ultrasonography contribute to public health awareness and promotion which in long term could potentially benefit in disease prevention and essentially promote better standards of healthcare.

  15. Demonstrating quantum random with single photons

    International Nuclear Information System (INIS)

    Bronner, Patrick; Strunz, Andreas; Meyn, Jan-Peter; Silberhorn, Christine

    2009-01-01

    We present an experiment for education which demonstrates random transmission or reflection of heralded single photons on beam splitters. With our set-up, we can realize different quantum random experiments by appropriate settings of polarization rotators. The concept of entanglement is motivated by correlated randomness. The experiments are suitable for undergraduate education and are available as interactive screen experiments.

  16. Vision screening with the RDE stereotest in pediatric populations.

    Science.gov (United States)

    Schmidt, P P

    1994-04-01

    The usefulness of the Random Dot E (RDE) stereotest in screening the vision of school-aged children for vision problems has been established. As a single screening procedure, the effectivity (phi) of the RDE (phi = +0.52) is greater than the widely used Snellen acuity technique (phi = +0.36) and faster to complete. Very-low-birthweight (VLBW) children have a higher incidence of vision problems including strabismus, amblyopia, and refractive error than children born with normal-birthweights (NBW's). My purpose was to determine: (1) whether a group of young children at high risk for vision problems could perform random dot stereotesting and (2) an age appropriate pass/fail criterion for stereoacuity screening. Furthermore, categorization as pass or fail by each screening method studied [stereoacuity (RDE), visual acuity [Teller Acuity Cards (TAC) and Broken Wheel (BWA)] and refractive error] was compared for independent agreement with vision examination results. The subjects were a cohort of NBW and VLBW) (RDE); 81.2%, 64.3% (TAC); 52.9%, 92.3% (BWA); and 94.1%, 61.5% (refractive error), respectively, (3) the reliability the RDE stereoacuity screening was greater (k = +0.66) than any of the other procedures studied, and (4) there was 73.3% agreement on test-retest categorizations between observers.(ABSTRACT TRUNCATED AT 250 WORDS)

  17. Premarital screening for hemoglobinopathies: experience of a single center in Kurdistan, Iraq.

    Science.gov (United States)

    Al-Allawi, Nasir A S; Al-Doski, Adnan A S; Markous, Raji S D; Mohamad Amin, Khyria A K; Eissa, Adil A Z; Badi, Ameer I A; Asmaro, Rafal R H; Hamamy, Hanan

    2015-01-01

    A program for the prevention of major hemoglobinopathies was initiated in 2008 in the Kurdistan region of Iraq. This study reports on the achievements and challenges of the program. A total of 102,554 individuals (51,277 couples) visiting a premarital center between 2008 and 2012 were screened for carrier status of hemoglobinopathies, and at-risk couples were counseled. A total of 223 (4.3/1,000) couples were identified and counseled as high-risk couples. Available data on 198 high-risk couples indicated that 90.4% proceeded with their marriage plans, and 15% of these married couples decided to have prenatal diagnosis (PND) in subsequent pregnancies with the identification of 8 affected fetuses; all were terminated as chosen by the parents. Thirty affected births were recorded among the high-risk couples. The premarital program managed to reduce the affected birth rate of major hemoglobinopathies by 21.1%. Of the 136 affected babies born during the study period, 77.9% were born to couples married prior to the start of the program, while 22.1% were born to couples identified as having a high risk. The main reason for not taking the option of PND was unaffordable costs. Financial support would have increased opting for PND by high-risk couples. Further reduction in affected birth rates could be achieved by including parallel antenatal screening programs to cover those married before the initiation of the premarital program and improving the public health education and counseling programs. © 2015 S. Karger AG, Basel.

  18. From structure prediction to genomic screens for novel non-coding RNAs.

    Science.gov (United States)

    Gorodkin, Jan; Hofacker, Ivo L

    2011-08-01

    Non-coding RNAs (ncRNAs) are receiving more and more attention not only as an abundant class of genes, but also as regulatory structural elements (some located in mRNAs). A key feature of RNA function is its structure. Computational methods were developed early for folding and prediction of RNA structure with the aim of assisting in functional analysis. With the discovery of more and more ncRNAs, it has become clear that a large fraction of these are highly structured. Interestingly, a large part of the structure is comprised of regular Watson-Crick and GU wobble base pairs. This and the increased amount of available genomes have made it possible to employ structure-based methods for genomic screens. The field has moved from folding prediction of single sequences to computational screens for ncRNAs in genomic sequence using the RNA structure as the main characteristic feature. Whereas early methods focused on energy-directed folding of single sequences, comparative analysis based on structure preserving changes of base pairs has been efficient in improving accuracy, and today this constitutes a key component in genomic screens. Here, we cover the basic principles of RNA folding and touch upon some of the concepts in current methods that have been applied in genomic screens for de novo RNA structures in searches for novel ncRNA genes and regulatory RNA structure on mRNAs. We discuss the strengths and weaknesses of the different strategies and how they can complement each other.

  19. Differentially pumped spray deposition as a rapid screening tool for organic and perovskite solar cells

    Science.gov (United States)

    Jung, Yen-Sook; Hwang, Kyeongil; Scholes, Fiona H.; Watkins, Scott E.; Kim, Dong-Yu; Vak, Doojin

    2016-01-01

    We report a spray deposition technique as a screening tool for solution processed solar cells. A dual-feed spray nozzle is introduced to deposit donor and acceptor materials separately and to form blended films on substrates in situ. Using a differential pump system with a motorised spray nozzle, the effect of film thickness, solution flow rates and the blend ratio of donor and acceptor materials on device performance can be found in a single experiment. Using this method, polymer solar cells based on poly(3-hexylthiophene) (P3HT):(6,6)-phenyl C61 butyric acid methyl ester (PC61BM) are fabricated with numerous combinations of thicknesses and blend ratios. Results obtained from this technique show that the optimum ratio of materials is consistent with previously reported values confirming this technique is a very useful and effective screening method. This high throughput screening method is also used in a single-feed configuration. In the single-feed mode, methylammonium iodide solution is deposited on lead iodide films to create a photoactive layer of perovskite solar cells. Devices featuring a perovskite layer fabricated by this spray process demonstrated a power conversion efficiencies of up to 7.9%. PMID:26853266

  20. Differentially pumped spray deposition as a rapid screening tool for organic and perovskite solar cells.

    Science.gov (United States)

    Jung, Yen-Sook; Hwang, Kyeongil; Scholes, Fiona H; Watkins, Scott E; Kim, Dong-Yu; Vak, Doojin

    2016-02-08

    We report a spray deposition technique as a screening tool for solution processed solar cells. A dual-feed spray nozzle is introduced to deposit donor and acceptor materials separately and to form blended films on substrates in situ. Using a differential pump system with a motorised spray nozzle, the effect of film thickness, solution flow rates and the blend ratio of donor and acceptor materials on device performance can be found in a single experiment. Using this method, polymer solar cells based on poly(3-hexylthiophene) (P3HT):(6,6)-phenyl C61 butyric acid methyl ester (PC61BM) are fabricated with numerous combinations of thicknesses and blend ratios. Results obtained from this technique show that the optimum ratio of materials is consistent with previously reported values confirming this technique is a very useful and effective screening method. This high throughput screening method is also used in a single-feed configuration. In the single-feed mode, methylammonium iodide solution is deposited on lead iodide films to create a photoactive layer of perovskite solar cells. Devices featuring a perovskite layer fabricated by this spray process demonstrated a power conversion efficiencies of up to 7.9%.

  1. Colon cancer screening

    Science.gov (United States)

    Screening for colon cancer; Colonoscopy - screening; Sigmoidoscopy - screening; Virtual colonoscopy - screening; Fecal immunochemical test; Stool DNA test; sDNA test; Colorectal cancer - screening; Rectal ...

  2. An experience of qualified preventive screening: shiraz smart screening software.

    Science.gov (United States)

    Islami Parkoohi, Parisa; Zare, Hashem; Abdollahifard, Gholamreza

    2015-01-01

    Computerized preventive screening software is a cost effective intervention tool to address non-communicable chronic diseases. Shiraz Smart Screening Software (SSSS) was developed as an innovative tool for qualified screening. It allows simultaneous smart screening of several high-burden chronic diseases and supports reminder notification functionality. The extent in which SSSS affects screening quality is also described. Following software development, preventive screening and annual health examinations of 261 school staff (Medical School of Shiraz, Iran) was carried out in a software-assisted manner. To evaluate the quality of the software-assisted screening, we used quasi-experimental study design and determined coverage, irregular attendance and inappropriateness proportions in relation with the manual and software-assisted screening as well as the corresponding number of requested tests. In manual screening method, 27% of employees were covered (with 94% irregular attendance) while by software-assisted screening, the coverage proportion was 79% (attendance status will clear after the specified time). The frequency of inappropriate screening test requests, before the software implementation, was 41.37% for fasting plasma glucose, 41.37% for lipid profile, 0.84% for occult blood, 0.19% for flexible sigmoidoscopy/colonoscopy, 35.29% for Pap smear, 19.20% for mammography and 11.2% for prostate specific antigen. All of the above were corrected by the software application. In total, 366 manual screening and 334 software-assisted screening tests were requested. SSSS is an innovative tool to improve the quality of preventive screening plans in terms of increased screening coverage, reduction in inappropriateness and the total number of requested tests.

  3. The Relations Between False Positive and Negative Screens and Smoking Cessation and Relapse in the National Lung Screening Trial: Implications for Public Health.

    Science.gov (United States)

    Clark, Melissa A; Gorelick, Jeremy J; Sicks, JoRean D; Park, Elyse R; Graham, Amanda L; Abrams, David B; Gareen, Ilana F

    2016-01-01

    Lung screening is an opportunity for smoking cessation and relapse prevention, but smoking behaviors may differ across screening results. Changes in smoking were evaluated among 18 840 current and former smokers aged 55-74 scheduled to receive three annual lung screenings. Participants were randomized to low-dose computed tomography or single-view chest radiography in the American College of Radiology/National Lung Screening Trial. Outcome measures included point and sustained (6-month) abstinence and motivation to quit among smokers; and relapse among smokers who quit during follow-up, recent quitters (quit < 6 months), and long-term former smokers (quit ≥ 6 months). During five years of follow-up, annual point prevalence quit rates ranged from 11.6%-13.4%; 48% of current smokers reported a quit attempt and 7% of long-term former smokers relapsed. Any false positive screening result was associated with subsequent increased point (multivariable hazard ratio HR = 1.23, 95% CI = 1.13, 1.35) and sustained (HR = 1.28, 95% CI = 1.15, 1.43) abstinence among smokers. Recent quitters with ≥1 false positive screen were less likely to relapse (HR = 0.72, 95% CI = 0.54, 0.96). Screening result was not associated with relapse among long-term former smokers or among baseline smokers who quit during follow-up. A false positive screen was associated with increased smoking cessation and less relapse among recent quitters. Consistently negative screens were not associated with greater relapse among long-term former smokers. Given the Affordable Care Act requires most health plans to cover smoking cessation and lung screening, the impact and cost-effectiveness of lung screening could be further enhanced with the addition of smoking cessation interventions. © The Author 2015. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  4. Multimodal lung cancer screening using the ITALUNG biomarker panel and low dose computed tomography. Results of the ITALUNG biomarker study.

    Science.gov (United States)

    Carozzi, Francesca Maria; Bisanzi, Simonetta; Carrozzi, Laura; Falaschi, Fabio; Lopes Pegna, Andrea; Mascalchi, Mario; Picozzi, Giulia; Peluso, Marco; Sani, Cristina; Greco, Luana; Ocello, Cristina; Paci, Eugenio

    2017-07-01

    Asymptomatic high-risk subjects, randomized in the intervention arm of the ITALUNG trial (1,406 screened for lung cancer), were enrolled for the ITALUNG biomarker study (n = 1,356), in which samples of blood and sputum were analyzed for plasma DNA quantification (cut off 5 ng/ml), loss of heterozygosity and microsatellite instability. The ITALUNG biomarker panel (IBP) was considered positive if at least one of the two biomarkers included in the panel was positive. Subjects with and without lung cancer diagnosis at the end of the screening cycle with LDCT (n = 517) were evaluated. Out of 18 baseline screen detected lung cancer cases, 17 were IBP positive (94%). Repeat screen-detected lung cancer cases were 18 and 12 of them positive at baseline IBP test (66%). Interval cancer cases (2-years) and biomarker tests after a suspect Non Calcific Nodule follow-up were investigated. The single test versus multimodal screening measures of accuracy were compared in a simulation within the screened ITALUNG intervention arm, considering screen-detected and interval cancer cases. Sensitivity was 90% at baseline screening. Specificity was 71 and 61% for LDCT and IBP as baseline single test, and improved at 89% with multimodal, combined screening. The positive predictive value was 4.3% for LDCT at baseline and 10.6% for multimodal screening. Multimodal screening could improve the screening efficiency at baseline and strategies for future implementation are discussed. If IBP was used as primary screening test, the LDCT burden might decrease of about 60%. © 2017 UICC.

  5. High-throughput screening for industrial enzyme production hosts by droplet microfluidics

    DEFF Research Database (Denmark)

    Sjostrom, Staffan L.; Bai, Yunpeng; Huang, Mingtao

    2014-01-01

    A high-throughput method for single cell screening by microfluidic droplet sorting is applied to a whole-genome mutated yeast cell library yielding improved production hosts of secreted industrial enzymes. The sorting method is validated by enriching a yeast strain 14 times based on its α......-amylase production, close to the theoretical maximum enrichment. Furthermore, a 105 member yeast cell library is screened yielding a clone with a more than 2-fold increase in α-amylase production. The increase in enzyme production results from an improvement of the cellular functions of the production host...

  6. Development and application of a general plasmid reference material for GMO screening.

    Science.gov (United States)

    Wu, Yuhua; Li, Jun; Wang, Yulei; Li, Xiaofei; Li, Yunjing; Zhu, Li; Li, Jun; Wu, Gang

    The use of analytical controls is essential when performing GMO detection through screening tests. Additionally, the presence of taxon-specific sequences is analyzed mostly for quality control during GMO detection. In this study, 11 commonly used genetic elements involving three promoters (P-35S, P-FMV35S and P-NOS), four marker genes (Bar, NPTII, HPT and Pmi), and four terminators (T-NOS, T-35S, T-g7 and T-e9), together with the reference gene fragments from six major crops of maize, soybean, rapeseed, rice, cotton and wheat, were co-integrated into the same single plasmid to construct a general reference plasmid pBI121-Screening. The suitability test of pBI121-Screening plasmid as reference material indicated that the non-target sequence on the pBI121-Screening plasmid did not affect the PCR amplification efficiencies of screening methods and taxon-specific methods. The sensitivity of screening and taxon-specific assays ranged from 5 to 10 copies of pBI121-Screening plasmid, meeting the sensitivity requirement of GMO detection. The construction of pBI121-Screening solves the lack of a general positive control for screening tests, thereby reducing the workload and cost of preparing a plurality of the positive control. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Unattached fraction of short-lived Rn decay products in indoor and outdoor environments: An improved single-screen method and results

    International Nuclear Information System (INIS)

    Reineking, A.; Porstendoerfer, J.

    1990-01-01

    The unattached fraction fp of potential alpha energy of short-lived Rn decay products was measured under realistic, natural conditions in different dwellings and in the open atmosphere by a single-screen technique. An improved data evaluation method was developed where the measured activities of 218 Po (RaA) and 214 Pb (RaB) were corrected by the screen-attached activities of 214 Bi ( 214 Po) [RaC (RaC')]. This method is based on the experimental observation that the 214 Bi ( 214 Po) unattached activities are negligible under realistic living conditions and that the size distributions of the aerosol-attached activities of all short-lived Rn daughters are identical. In closed rooms without additional aerosol sources, a mean unattached fraction fp of the potential alpha energy of 0.096 was obtained at a mean aerosol particle concentration of 6100 cm-3 and at a mean equilibrium factor F of 0.30. This mean fp value is about three times higher than the value used in the literature for the radiation exposure calculation of the human public. In closed rooms with additional aerosol sources (cigarette smoke, heating systems, aerosols from a burning candle), the aerosol particle concentrations ranged up to 10(6) cm-3 and the attachment rates, X, increased up to 1000 h-1. The fp values sometimes decreased below the detection limit of 0.005, and the F values increased to as high as 0.77. In the ambient atmosphere in the vicinity of Goettingen, a mean unattached fraction fp of 0.02 and a mean aerosol particle concentration of 3.4 x 10(4) cm-3 were measured at 1 m above the ground. The mean equilibrium factor F was determined to be 0.7.A

  8. Screening the Hanford tanks for trapped gas

    International Nuclear Information System (INIS)

    Whitney, P.

    1995-10-01

    The Hanford Site is home to 177 large, underground nuclear waste storage tanks. Hydrogen gas is generated within the waste in these tanks. This document presents the results of a screening of Hanford's nuclear waste storage tanks for the presence of gas trapped in the waste. The method used for the screening is to look for an inverse correlation between waste level measurements and ambient atmospheric pressure. If the waste level in a tank decreases with an increase in ambient atmospheric pressure, then the compressibility may be attributed to gas trapped within the waste. In this report, this methodology is not used to estimate the volume of gas trapped in the waste. The waste level measurements used in this study were made primarily to monitor the tanks for leaks and intrusions. Four measurement devices are widely used in these tanks. Three of these measure the level of the waste surface. The remaining device measures from within a well embedded in the waste, thereby monitoring the liquid level even if the liquid level is below a dry waste crust. In the past, a steady rise in waste level has been taken as an indicator of trapped gas. This indicator is not part of the screening calculation described in this report; however, a possible explanation for the rise is given by the mathematical relation between atmospheric pressure and waste level used to support the screening calculation. The screening was applied to data from each measurement device in each tank. If any of these data for a single tank indicated trapped gas, that tank was flagged by this screening process. A total of 58 of the 177 Hanford tanks were flagged as containing trapped gas, including 21 of the 25 tanks currently on the flammable gas watch list

  9. Screening for chlamydial infection.

    Science.gov (United States)

    Nelson, H D; Helfand, M

    2001-04-01

    To examine data on the effectiveness of screening for chlamydial infection by a physician or other health care professional. Specifically, we examine the evidence that early treatment of chlamydial infection improves health outcomes, as well as evidence of the effectiveness of screening strategies in nonpregnant women, pregnant women, and men, and the accuracy of tests used for screening. This review updates the literature since the last recommendation of the U.S. Preventive Services Task Force published in 1996. We searched the topic of chlamydia in the MEDLINE, HealthSTAR, and Cochrane Library databases from January 1994 to July 2000, supplemented by reference lists of relevant articles and from experts in the field. Articles published prior to 1994 and research abstracts were cited if particularly important to the key questions or to the interpretation of included articles. A single reader reviewed all English abstracts. Articles were selected for full review if they were about Chlamydia trachomatis genitourinary infections in nonpregnant women, pregnant women, or men and were relevant to key questions in the analytic framework. Investigators read the full-text version of the retrieved articles and applied additional eligibility criteria. For all topics, we excluded articles if they did not provide sufficient information to determine the methods for selecting subjects and for analyzing data. We systematically reviewed three types of studies about screening in nonpregnant women that relate to three key questions: (1) studies about the effectiveness of screening programs in reducing prevalence rates of infection, (2) studies about risk factors for chlamydial infection in women, and (3) studies about chlamydial screening tests in women. Our search found too few studies on pregnant women to systematically review, although pertinent studies are described. We systematically reviewed two types of studies about screening in men: (1) studies about prevalence rates and

  10. Participant selection for lung cancer screening by risk modelling (the Pan-Canadian Early Detection of Lung Cancer [PanCan] study): a single-arm, prospective study.

    Science.gov (United States)

    Tammemagi, Martin C; Schmidt, Heidi; Martel, Simon; McWilliams, Annette; Goffin, John R; Johnston, Michael R; Nicholas, Garth; Tremblay, Alain; Bhatia, Rick; Liu, Geoffrey; Soghrati, Kam; Yasufuku, Kazuhiro; Hwang, David M; Laberge, Francis; Gingras, Michel; Pasian, Sergio; Couture, Christian; Mayo, John R; Nasute Fauerbach, Paola V; Atkar-Khattra, Sukhinder; Peacock, Stuart J; Cressman, Sonya; Ionescu, Diana; English, John C; Finley, Richard J; Yee, John; Puksa, Serge; Stewart, Lori; Tsai, Scott; Haider, Ehsan; Boylan, Colm; Cutz, Jean-Claude; Manos, Daria; Xu, Zhaolin; Goss, Glenwood D; Seely, Jean M; Amjadi, Kayvan; Sekhon, Harmanjatinder S; Burrowes, Paul; MacEachern, Paul; Urbanski, Stefan; Sin, Don D; Tan, Wan C; Leighl, Natasha B; Shepherd, Frances A; Evans, William K; Tsao, Ming-Sound; Lam, Stephen

    2017-11-01

    Results from retrospective studies indicate that selecting individuals for low-dose CT lung cancer screening on the basis of a highly predictive risk model is superior to using criteria similar to those used in the National Lung Screening Trial (NLST; age, pack-year, and smoking quit-time). We designed the Pan-Canadian Early Detection of Lung Cancer (PanCan) study to assess the efficacy of a risk prediction model to select candidates for lung cancer screening, with the aim of determining whether this approach could better detect patients with early, potentially curable, lung cancer. We did this single-arm, prospective study in eight centres across Canada. We recruited participants aged 50-75 years, who had smoked at some point in their life (ever-smokers), and who did not have a self-reported history of lung cancer. Participants had at least a 2% 6-year risk of lung cancer as estimated by the PanCan model, a precursor to the validated PLCOm2012 model. Risk variables in the model were age, smoking duration, pack-years, family history of lung cancer, education level, body-mass index, chest x-ray in the past 3 years, and history of chronic obstructive pulmonary disease. Individuals were screened with low-dose CT at baseline (T0), and at 1 (T1) and 4 (T4) years post-baseline. The primary outcome of the study was incidence of lung cancer. This study is registered with ClinicalTrials.gov, number NCT00751660. 7059 queries came into the study coordinating centre and were screened for PanCan risk. 15 were duplicates, so 7044 participants were considered for enrolment. Between Sept 24, 2008, and Dec 17, 2010, we recruited and enrolled 2537 eligible ever-smokers. After a median follow-up of 5·5 years (IQR 3·2-6·1), 172 lung cancers were diagnosed in 164 individuals (cumulative incidence 0·065 [95% CI 0·055-0·075], incidence rate 138·1 per 10 000 person-years [117·8-160·9]). There were ten interval lung cancers (6% of lung cancers and 6% of individuals with cancer

  11. The cumulative risk of false-positive screening results across screening centres in the Norwegian Breast Cancer Screening Program

    Energy Technology Data Exchange (ETDEWEB)

    Roman, M., E-mail: Marta.Roman@kreftregisteret.no [Cancer Registry of Norway, Oslo (Norway); Department of Women and Children’s Health, Oslo University Hospital, Oslo (Norway); Skaane, P., E-mail: PERSK@ous-hf.no [Department of Radiology, Oslo University Hospital Ullevaal, University of Oslo, Oslo (Norway); Hofvind, S., E-mail: Solveig.Hofvind@kreftregisteret.no [Cancer Registry of Norway, Oslo (Norway); Oslo and Akershus University College of Applied Sciences, Faculty of Health Science, Oslo (Norway)

    2014-09-15

    Highlights: • We found variation in early performance measures across screening centres. • Radiologists’ performance may play a key role in the variability. • Potential to improve the effectiveness of breast cancer screening programs. • Continuous surveillance of screening centres and radiologists is essential. - Abstract: Background: Recall for assessment in mammographic screening entails an inevitable number of false-positive screening results. This study aimed to investigate the variation in the cumulative risk of a false positive screening result and the positive predictive value across the screening centres in the Norwegian Breast Cancer Screening Program. Methods: We studied 618,636 women aged 50–69 years who underwent 2,090,575 screening exams (1996–2010. Recall rate, positive predictive value, rate of screen-detected cancer, and the cumulative risk of a false positive screening result, without and with invasive procedures across the screening centres were calculated. Generalized linear models were used to estimate the probability of a false positive screening result and to compute the cumulative false-positive risk for up to ten biennial screening examinations. Results: The cumulative risk of a false-positive screening exam varied from 10.7% (95% CI: 9.4–12.0%) to 41.5% (95% CI: 34.1–48.9%) across screening centres, with a highest to lowest ratio of 3.9 (95% CI: 3.7–4.0). The highest to lowest ratio for the cumulative risk of undergoing an invasive procedure with a benign outcome was 4.3 (95% CI: 4.0–4.6). The positive predictive value of recall varied between 12.0% (95% CI: 11.0–12.9%) and 19.9% (95% CI: 18.3–21.5%), with a highest to lowest ratio of 1.7 (95% CI: 1.5–1.9). Conclusions: A substantial variation in the performance measures across the screening centres in the Norwegian Breast Cancer Screening Program was identified, despite of similar administration, procedures, and quality assurance requirements. Differences in the

  12. The cumulative risk of false-positive screening results across screening centres in the Norwegian Breast Cancer Screening Program

    International Nuclear Information System (INIS)

    Roman, M.; Skaane, P.; Hofvind, S.

    2014-01-01

    Highlights: • We found variation in early performance measures across screening centres. • Radiologists’ performance may play a key role in the variability. • Potential to improve the effectiveness of breast cancer screening programs. • Continuous surveillance of screening centres and radiologists is essential. - Abstract: Background: Recall for assessment in mammographic screening entails an inevitable number of false-positive screening results. This study aimed to investigate the variation in the cumulative risk of a false positive screening result and the positive predictive value across the screening centres in the Norwegian Breast Cancer Screening Program. Methods: We studied 618,636 women aged 50–69 years who underwent 2,090,575 screening exams (1996–2010. Recall rate, positive predictive value, rate of screen-detected cancer, and the cumulative risk of a false positive screening result, without and with invasive procedures across the screening centres were calculated. Generalized linear models were used to estimate the probability of a false positive screening result and to compute the cumulative false-positive risk for up to ten biennial screening examinations. Results: The cumulative risk of a false-positive screening exam varied from 10.7% (95% CI: 9.4–12.0%) to 41.5% (95% CI: 34.1–48.9%) across screening centres, with a highest to lowest ratio of 3.9 (95% CI: 3.7–4.0). The highest to lowest ratio for the cumulative risk of undergoing an invasive procedure with a benign outcome was 4.3 (95% CI: 4.0–4.6). The positive predictive value of recall varied between 12.0% (95% CI: 11.0–12.9%) and 19.9% (95% CI: 18.3–21.5%), with a highest to lowest ratio of 1.7 (95% CI: 1.5–1.9). Conclusions: A substantial variation in the performance measures across the screening centres in the Norwegian Breast Cancer Screening Program was identified, despite of similar administration, procedures, and quality assurance requirements. Differences in the

  13. Alcohol Use Screening

    Science.gov (United States)

    ... Depression Screening Substance Abuse Screening Alcohol Use Screening Alcohol Use Screening (AUDIT-C) - Instructions The following questions ... this tool, there is also text-only version . Alcohol Use Screening (AUDIT-C) - Manual Instructions The following ...

  14. Final screening round of the NELSON lung cancer screening trial: the effect of a 2.5-year screening interval

    NARCIS (Netherlands)

    Yousaf-Khan, U.; Aalst, C. van der; Jong, P.A. de; Heuvelmans, M.; Scholten, E.T.; Lammers, J.-W.J.; Ooijen, P. van; Nackaerts, K.; Weenink, C.; Groen, H.; Vliegenthart, R.; Haaf, K. Ten; Oudkerk, M.; Koning, H. de

    2016-01-01

    In the USA annual lung cancer screening is recommended. However, the optimal screening strategy (eg, screening interval, screening rounds) is unknown. This study provides results of the fourth screening round after a 2.5-year interval in the Dutch-Belgian Lung Cancer Screening trial

  15. Final screening round of the NELSON lung cancer screening trial : the effect of a 2.5-year screening interval

    NARCIS (Netherlands)

    Yousaf-Khan, Uraujh; van der Aalst, Carlijn; de Jong, Pim A; Heuvelmans, Marjolein; Scholten, Ernst; Lammers, Jan-Willem; van Ooijen, Peter; Nackaerts, Kristiaan; Weenink, Carla; Groen, Harry; Vliegenthart, Rozemarijn; Ten Haaf, Kevin; Oudkerk, Matthijs; de Koning, Harry

    BACKGROUND: In the USA annual lung cancer screening is recommended. However, the optimal screening strategy (eg, screening interval, screening rounds) is unknown. This study provides results of the fourth screening round after a 2.5-year interval in the Dutch-Belgian Lung Cancer Screening trial

  16. Final screening round of the NELSON lung cancer screening trial : the effect of a 2.5-year screening interval

    NARCIS (Netherlands)

    Yousaf-Khan, Uraujh; van der Aalst, Carlijn; de Jong, Pim A.; Heuvelmans, Marjolein; Scholten, Ernst; Lammers, Jan-Willem; van Ooijen, Peter; Nackaerts, Kristiaan; Weenink, Carla; Groen, Harry; Vliegenthart, Rozemarijn; Ten Haaf, Kevin; Oudkerk, Matthijs; de Koning, Harry

    Background In the USA annual lung cancer screening is recommended. However, the optimal screening strategy (eg, screening interval, screening rounds) is unknown. This study provides results of the fourth screening round after a 2.5-year interval in the Dutch-Belgian Lung Cancer Screening trial

  17. Screening for carcinoma in situ in the contralateral testicle in patients with testicular cancer

    DEFF Research Database (Denmark)

    Kier, M G G; Lauritsen, Jakob; Almstrup, Kristian

    2015-01-01

    population-based screening programme for contralateral CIS in patients with testicular cancer showed no significant difference in the risk for metachronous GCC between a screened and an unscreened cohort. Single-site biopsy including modern immunohistochemistry does not identify all cases of CIS.......BACKGROUND: Screening programmes for contralateral carcinoma in situ (CIS) testis in patients with unilateral germ-cell cancer (GCC) have never been evaluated. We investigated the effect of screening for contralateral CIS in a large nation-wide, population-based study. PATIENTS AND METHODS...... years was 1.9% in the screened cohort and 3.1% in the unscreened cohort (P = 0.097), hazard ratio (HR) for the unscreened cohort: 1.59 (P = 0.144). Expert revision with contemporary methodology of CIS-negative biopsy samples from patients with metachronous cancer revealed CIS in 17 out of 45 (38%) cases...

  18. Using the Screened Coulomb Potential to Illustrate the Variational Method

    Science.gov (United States)

    Zuniga, Jose; Bastida, Adolfo; Requena, Alberto

    2012-01-01

    The screened Coulomb potential, or Yukawa potential, is used to illustrate the application of the single and linear variational methods. The trial variational functions are expressed in terms of Slater-type functions, for which the integrals needed to carry out the variational calculations are easily evaluated in closed form. The variational…

  19. Single photon transport by a moving atom

    International Nuclear Information System (INIS)

    Afanasiev, A E; Melentiev, P N; Kuzin, A A; Yu Kalatskiy, A; Balykin, V I

    2017-01-01

    The results of investigation of photon transport through the subwavelength hole in the opaque screen by using single neutral atom are represented. The basis of the proposed and implemented method is the absorption of a photon by a neutral atom immediately before the subwavelength aperture, traveling of the atoms through the hole and emission of a photon on the other side of the screen. Realized method is the alternative approach to existing for photon transport through a subwavelength aperture: 1) self-sustained transmittance of a photon through the aperture according to the Bethe’s model; 2) extra ordinary transmission because of surface-plasmon excitation. (paper)

  20. Nanoscale high-content analysis using compositional heterogeneities of single proteoliposomes

    DEFF Research Database (Denmark)

    Mathiasen, Signe; Christensen, Sune M.; Fung, Juan José

    2014-01-01

    Proteoliposome reconstitution is a standard method to stabilize purified transmembrane proteins in membranes for structural and functional assays. Here we quantified intrareconstitution heterogeneities in single proteoliposomes using fluorescence microscopy. Our results suggest that compositional...... heterogeneities can severely skew ensemble-average proteoliposome measurements but also enable ultraminiaturized high-content screens. We took advantage of this screening capability to map the oligomerization energy of the β2-adrenergic receptor using ∼10(9)-fold less protein than conventional assays....

  1. Evaluation of the concomitant use of two different EIA tests for HIV screening in blood banks

    Directory of Open Access Journals (Sweden)

    Otani Marcia M.

    2003-01-01

    Full Text Available OBJECTIVE: In 1998, the Brazilian Ministry of Health made it mandatory for all blood banks in the country to screen donated blood for human immunodeficiency virus (HIV concomitantly using two different enzyme immunoassay (EIA tests. Concerned with the best use of available resources, our objective with this study was to evaluate the usefulness of conducting two EIA screening tests instead of just one. METHODS: We analyzed data from 1999 through 2001 obtained by testing 698 191 units of donated blood using two EIA HIV screening tests concomitantly at the Pro-Blood Foundation/Blood Center of São Paulo (Fundação Pró-Sangue/Hemocentro de São Paulo, which is a major blood center in the city of São Paulo, Brazil. All samples reactive in at least one of the two EIA tests were submitted for confirmation by a Western blot (WB test, and the persons who had donated those samples were also asked to return and provide a follow-up sample. RESULTS: Out of the 698 191 blood units that were donated, 2 718 of them (0.4% had to be discarded because they were reactive to at least one of the EIA tests. There were two WB-positive donation samples that were reactive in only one HIV EIA screening test. On their follow-up samples, both donors tested WB-negative. These cases were considered false positive results at screening. Of the 2 718 donors who were asked to return and provide a follow-up sample, 1 576 of them (58% did so. From these 1 576 persons, we found that there were two individuals who had been reactive to only one of the two EIA screening tests and who had also been negative on the WB at screening but who were fully seroconverted on the follow-up sample. We thus estimated that, in comparison to the use of a single EIA screening test, the use of two EIA screening tests would detect only one extra sample out of 410 700 units of blood. CONCLUSIONS: Our data do not support the use of two different, concomitant EIA screening tests for HIV. The great

  2. SELEX-Based Screening of Exosome-Tropic RNA.

    Science.gov (United States)

    Yamashita, Takuma; Shinotsuka, Haruka; Takahashi, Yuki; Kato, Kana; Nishikawa, Makiya; Takakura, Yoshinobu

    2017-01-01

    Cell-derived nanosized vesicles or exosomes are expected to become delivery carriers for functional RNAs, such as small interfering RNA (siRNA). A method to efficiently load functional RNAs into exosomes is required for the development of exosome-based delivery carriers of functional RNAs. However, there is no method to find exosome-tropic exogenous RNA sequences. In this study, we used a systematic evolution of ligands by exponential enrichment (SELEX) method to screen exosome-tropic RNAs that can be used to load functional RNAs into exosomes by conjugation. Pooled single stranded 80-base RNAs, each of which contains a randomized 40-base sequence, were transfected into B16-BL6 murine melanoma cells and exosomes were collected from the cells. RNAs extracted from the exosomes were subjected to next round of SELEX. Cloning and sequencing of RNAs in SELEX-screened RNA pools showed that 29 of 56 clones had a typical RNA sequence. The sequence found by SELEX was enriched in exosomes after transfection to B16-BL6 cells. The results show that the SELEX-based method can be used for screening of exosome-tropic RNAs.

  3. Screensaver: an open source lab information management system (LIMS for high throughput screening facilities

    Directory of Open Access Journals (Sweden)

    Nale Jennifer

    2010-05-01

    Full Text Available Abstract Background Shared-usage high throughput screening (HTS facilities are becoming more common in academe as large-scale small molecule and genome-scale RNAi screening strategies are adopted for basic research purposes. These shared facilities require a unique informatics infrastructure that must not only provide access to and analysis of screening data, but must also manage the administrative and technical challenges associated with conducting numerous, interleaved screening efforts run by multiple independent research groups. Results We have developed Screensaver, a free, open source, web-based lab information management system (LIMS, to address the informatics needs of our small molecule and RNAi screening facility. Screensaver supports the storage and comparison of screening data sets, as well as the management of information about screens, screeners, libraries, and laboratory work requests. To our knowledge, Screensaver is one of the first applications to support the storage and analysis of data from both genome-scale RNAi screening projects and small molecule screening projects. Conclusions The informatics and administrative needs of an HTS facility may be best managed by a single, integrated, web-accessible application such as Screensaver. Screensaver has proven useful in meeting the requirements of the ICCB-Longwood/NSRB Screening Facility at Harvard Medical School, and has provided similar benefits to other HTS facilities.

  4. Screensaver: an open source lab information management system (LIMS) for high throughput screening facilities.

    Science.gov (United States)

    Tolopko, Andrew N; Sullivan, John P; Erickson, Sean D; Wrobel, David; Chiang, Su L; Rudnicki, Katrina; Rudnicki, Stewart; Nale, Jennifer; Selfors, Laura M; Greenhouse, Dara; Muhlich, Jeremy L; Shamu, Caroline E

    2010-05-18

    Shared-usage high throughput screening (HTS) facilities are becoming more common in academe as large-scale small molecule and genome-scale RNAi screening strategies are adopted for basic research purposes. These shared facilities require a unique informatics infrastructure that must not only provide access to and analysis of screening data, but must also manage the administrative and technical challenges associated with conducting numerous, interleaved screening efforts run by multiple independent research groups. We have developed Screensaver, a free, open source, web-based lab information management system (LIMS), to address the informatics needs of our small molecule and RNAi screening facility. Screensaver supports the storage and comparison of screening data sets, as well as the management of information about screens, screeners, libraries, and laboratory work requests. To our knowledge, Screensaver is one of the first applications to support the storage and analysis of data from both genome-scale RNAi screening projects and small molecule screening projects. The informatics and administrative needs of an HTS facility may be best managed by a single, integrated, web-accessible application such as Screensaver. Screensaver has proven useful in meeting the requirements of the ICCB-Longwood/NSRB Screening Facility at Harvard Medical School, and has provided similar benefits to other HTS facilities.

  5. Seek and you shall find--but then what do you do? Cold agglutinins in cardiopulmonary bypass and a single-center experience with cold agglutinin screening before cardiac surgery.

    Science.gov (United States)

    Jain, Michael D; Cabrerizo-Sanchez, Rosa; Karkouti, Keyvan; Yau, Terrence; Pendergrast, Jacob M; Cserti-Gazdewich, Christine M

    2013-04-01

    Cardiopulmonary bypass (CPB) during cardiac surgery can involve deliberate hypothermia of the systemic (22-36 °C) and coronary circulations (as low as 8-12 °C). Adverse sequelae of cold-active antibodies have been feared and reported under such conditions, and some centers thus elect to screen for cold agglutinins before CPB. We reviewed the literature on cold agglutinins in cardiac surgery and described the yields and effects of cold agglutinin screening (CAS) in 14,900 cardiac surgery patients undergoing CPB over 8 years at a single institution. Cold agglutinin screening was positive in 47 cases (0.3%), at an annual testing cost of $17,000 CAD. The response of the surgical team to the preoperative discovery of a cold agglutinin was variable, with CPB modified to avoid hypothermia in approximately one-third of cases. In patients discovered to have a positive CAS, postoperative intensive care unit and hospital length of stay were marginally increased (54.6 vs. 42.8 hours, P = .02; 7 [6-14] vs. 7 [5-9] days, P = .04). However, the composite of mortality or severe morbidity (stroke, myocardial infarction, dialysis, low output syndrome, sepsis, and deep vein thrombosis) was not significantly different (14.9% vs. 9.2%, P = .2). Antibody verification found that only 43% of positive CAS patients had true cold agglutinins (20 patients). Furthermore, the rate of adverse events was low in both CAS-positive and true-positive cold agglutinin patients undergoing CPB and cardiac surgery. Finally, modification of CPB to attenuate hypothermia did not decrease adverse events. Based upon historical and local data, preclinical CAS is cost-substantial and nonspecific. Cold agglutinin screening does not promote an algorithm of care that meaningfully improves patient CPB outcomes. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. Prostate Cancer Screening in Jamaica: Results of the Largest National Screening Clinic Prostate Cancer Screening in Jamaica: Results of the Largest National Screening Clinic

    International Nuclear Information System (INIS)

    Morrison, B. F.; Aiken, W.; Mayhew, R.; Gordon, Y.; Reid, M.

    2016-01-01

    Prostate cancer is highly prevalent in Jamaica and is the leading cause of cancer-related deaths. Our aim was to evaluate the patterns of screening in the largest organized screening clinic in Jamaica at the Jamaica Cancer Society. A retrospective analysis of all men presenting for screening at the Jamaica Cancer Society from 1995 to 2005 was done. All patients had digital rectal examinations (DRE) and prostate specific antigen (PSA) tests done. Results of prostate biopsies were noted. 1117 men of mean age 59.9 ± 8.2 years presented for screening. The median documented PSA was 1.6 ng/mL (maximum of 5170 ng/mL). Most patients presented for only 1 screen. There was a gradual reduction in the mean age of presentation for screening over the period. Prostate biopsies were requested on 11% of screening visits; however, only 59% of these were done. 5.6% of all persons screened were found to have cancer. Of the cancers diagnosed, Gleason 6 adenocarcinoma was the commonest grade and median PSA was 8.9 ng/mL (range 1.5-1059 ng/mL). Older men tend to screen for prostate cancer in Jamaica. However, compliance with regular maintenance visits and requests for confirmatory biopsies are poor. Screening needs intervention in the Jamaican population.

  7. Comment on Dynamic plasma screening effects on semiclassical inelastic electron ion collisions in dense plasmas [Phys. Plasmas 4, 21 (1997)

    International Nuclear Information System (INIS)

    Murillo, M.S.

    1997-01-01

    Jung's analysis of dynamics screening appears to be flawed by attempting to patch many-body effects into a single-body theory and a more rigorous foundation is necessary. Jung's result and dynamical screening have been previously analyzed many times

  8. Screening for self-plagiarism in a subspecialty-versus-general imaging journal using iThenticate.

    Science.gov (United States)

    Kalnins, A U; Halm, K; Castillo, M

    2015-06-01

    Self-plagiarism is a form of research misconduct that can dilute the credibility and reputation of a scientific journal, as well as the represented specialty. Journal editors are aware of this problem when reviewing submissions and use on-line plagiarism-analysis programs to facilitate detection. The American Journal of Neuroradiology (AJNR) uses iThenticate to screen several submitted original research manuscripts selected for review per issue and retrospectively assesses 3 issues per year. The prevalence of self-plagiarism in AJNR was compared with that in Radiology; the necessity and cost of more extensive screening in AJNR were evaluated. The self-duplication rate in AJNR original research articles was compared with that in Radiology, a general imaging journal that screens all submitted original research manuscripts selected for review by using iThenticate. The rate of self-duplication in original research articles from 2 randomly selected 2012 AJNR issues was compared with the rate in the prior year to gauge the need for more extensive screening. A cost analysis of screening all submitted original research manuscripts selected for review by using iThenticate was performed. Using an empiric 15% single-source duplication threshold, we found that the rate of significant self-plagiarism in original research articles was low for both journals. While AJNR had more articles exceeding this threshold, most instances were insignificant. Analyzing 2 randomly chosen issues of AJNR for single-source duplication of >15% in original research articles yielded no significant differences compared with an entire year. The approximate annual cost of screening all submitted original research manuscripts selected for review was US $6800.00. While the rate of self-plagiarism was low in AJNR and similar to that in Radiology, its potential cost in negative impact on AJNR and the subspecialty of neuroradiology justifies the costs of broader screening. © 2015 by American Journal of

  9. Genetic screening of EXT1 and EXT2 in Cypriot families with ...

    Indian Academy of Sciences (India)

    RESEARCH NOTE. Genetic screening of EXT1 and EXT2 in Cypriot families with hereditary .... on samples from the HMO patient's parents in an attempt to establish .... Intragenic deletions involving single or multiple EXT1 or. EXT2 exons are ...

  10. Screening for diabetic retinopathy in primary care with a mobile ...

    African Journals Online (AJOL)

    A SWOT analysis of the pilot project was completed and recommendations were made on how to integrate it into the district health system. Conclusion. Screening with a fundal camera improved the quality of care for diabetic patients and is feasible in the South African public sector, primary care setting. A single technician ...

  11. Automated Groundwater Screening

    International Nuclear Information System (INIS)

    Taylor, Glenn A.; Collard, Leonard B.

    2005-01-01

    The Automated Intruder Analysis has been extended to include an Automated Ground Water Screening option. This option screens 825 radionuclides while rigorously applying the National Council on Radiation Protection (NCRP) methodology. An extension to that methodology is presented to give a more realistic screening factor for those radionuclides which have significant daughters. The extension has the promise of reducing the number of radionuclides which must be tracked by the customer. By combining the Automated Intruder Analysis with the Automated Groundwater Screening a consistent set of assumptions and databases is used. A method is proposed to eliminate trigger values by performing rigorous calculation of the screening factor thereby reducing the number of radionuclides sent to further analysis. Using the same problem definitions as in previous groundwater screenings, the automated groundwater screening found one additional nuclide, Ge-68, which failed the screening. It also found that 18 of the 57 radionuclides contained in NCRP Table 3.1 failed the screening. This report describes the automated groundwater screening computer application

  12. From structure prediction to genomic screens for novel non-coding RNAs.

    Directory of Open Access Journals (Sweden)

    Jan Gorodkin

    2011-08-01

    Full Text Available Non-coding RNAs (ncRNAs are receiving more and more attention not only as an abundant class of genes, but also as regulatory structural elements (some located in mRNAs. A key feature of RNA function is its structure. Computational methods were developed early for folding and prediction of RNA structure with the aim of assisting in functional analysis. With the discovery of more and more ncRNAs, it has become clear that a large fraction of these are highly structured. Interestingly, a large part of the structure is comprised of regular Watson-Crick and GU wobble base pairs. This and the increased amount of available genomes have made it possible to employ structure-based methods for genomic screens. The field has moved from folding prediction of single sequences to computational screens for ncRNAs in genomic sequence using the RNA structure as the main characteristic feature. Whereas early methods focused on energy-directed folding of single sequences, comparative analysis based on structure preserving changes of base pairs has been efficient in improving accuracy, and today this constitutes a key component in genomic screens. Here, we cover the basic principles of RNA folding and touch upon some of the concepts in current methods that have been applied in genomic screens for de novo RNA structures in searches for novel ncRNA genes and regulatory RNA structure on mRNAs. We discuss the strengths and weaknesses of the different strategies and how they can complement each other.

  13. About the role of 2D screening in high temperature superconductivity

    International Nuclear Information System (INIS)

    Vazquez-Ponce, Y.; Oliva Aguero, D.; Cabo Montes de Oca, D.

    2005-09-01

    The 2D screening is investigated in a simple single band square tight-binding model which qualitatively resembles the known electronic structure in high temperature superconductors. The Coulomb kernel for the two particle Bethe-Salpeter equation in the single loop (RPA) approximation for the polarization can be evaluated in a strong tight binding limit. The results indicate an intense screening of the Coulomb repulsion between the particles, which becomes stronger and anisotropic when the Fermi level approaches half filling (or equivalently, when the Fermi surface turns to be near the Van Hove singularities) and rapidly decreases away from it. The effect is also more pronounced for quasi-momenta regions near the corners of the Brillouin cell, which corresponds to dual spatial distances of the order of a few unit cells. Therefore, a possible mechanism is identified which could explain the existence of extremely small Cooper pairs in these materials, as bounded anisotropic composite particles joined by residual superexchange or phonon interactions. (author)

  14. Quantifying the advantages and disadvantages of pre-placement genetic screening.

    Science.gov (United States)

    Palmer, K T; Poole, J; Rawbone, R G; Coggon, D

    2004-05-01

    Tests of genotype may enable workers at unusual risk of future ill-health to be identified. Using them to select for employment, however, entails gains and losses to employers and employees. Ensuring a fair balance between the rights and obligations of each group requires a value judgement, but the advantages and disadvantages to interested parties must first be quantified in a meaningful way. The purposes of pre-employment screening are reviewed, and several simple measures relevant to the separate interests of employers and job applicants proposed-number screened to prevent a single adverse outcome; number excluded to prevent a case; expected incidence of the adverse outcome in those excluded; and preventable fraction. The derivation of these measures is illustrated, and the factors that influence them (the prevalence of the prognostic trait, the relative risk that it carries for an adverse outcome, and the overall incidence of disease) are related algebraically and graphically, to aid judgement on the utility of screening under different circumstances. In sensitive areas such as genetic testing the onus should be on the employer to justify plans for pre-placement screening. Several quantitative measures can be used to inform the ethical and economic debate about screening and to evaluate alternative strategies for prevention.

  15. A comprehensive platform for highly multiplexed mammalian functional genetic screens

    Directory of Open Access Journals (Sweden)

    Cheung-Ong Kahlin

    2011-05-01

    Full Text Available Abstract Background Genome-wide screening in human and mouse cells using RNA interference and open reading frame over-expression libraries is rapidly becoming a viable experimental approach for many research labs. There are a variety of gene expression modulation libraries commercially available, however, detailed and validated protocols as well as the reagents necessary for deconvolving genome-scale gene screens using these libraries are lacking. As a solution, we designed a comprehensive platform for highly multiplexed functional genetic screens in human, mouse and yeast cells using popular, commercially available gene modulation libraries. The Gene Modulation Array Platform (GMAP is a single microarray-based detection solution for deconvolution of loss and gain-of-function pooled screens. Results Experiments with specially constructed lentiviral-based plasmid pools containing ~78,000 shRNAs demonstrated that the GMAP is capable of deconvolving genome-wide shRNA "dropout" screens. Further experiments with a larger, ~90,000 shRNA pool demonstrate that equivalent results are obtained from plasmid pools and from genomic DNA derived from lentivirus infected cells. Parallel testing of large shRNA pools using GMAP and next-generation sequencing methods revealed that the two methods provide valid and complementary approaches to deconvolution of genome-wide shRNA screens. Additional experiments demonstrated that GMAP is equivalent to similar microarray-based products when used for deconvolution of open reading frame over-expression screens. Conclusion Herein, we demonstrate four major applications for the GMAP resource, including deconvolution of pooled RNAi screens in cells with at least 90,000 distinct shRNAs. We also provide detailed methodologies for pooled shRNA screen readout using GMAP and compare next-generation sequencing to GMAP (i.e. microarray based deconvolution methods.

  16. Combinatorial drug screening identifies Ewing sarcoma-specific sensitivities

    OpenAIRE

    Radic-Sarikas, Branka; Tsafou, Kalliopi P.; Emdal, Kristina B.; Papamarkou, Theodore; Huber, Kilian V.M.; Mutz, Cornelia; Toretsky, Jeffrey A.; Bennett, Keiryn L.; Olsen, Jesper V.; Brunak, Søren; Kovar, Heinrich; Superti-Furga, Giulio

    2017-01-01

    Improvements in survival for Ewing sarcoma pediatric and adolescent patients have been modest over the past 20 years. Combinations of anticancer agents endure as an option to overcome resistance to single treatments caused by compensatory pathways. Moreover, combinations are thought to lessen any associated adverse side effects through reduced dosing, which is particularly important in childhood tumors. Using a parallel phenotypic combinatorial screening approach of cells derived from three p...

  17. Breast cancer screening

    Science.gov (United States)

    Mammogram - breast cancer screening; Breast exam - breast cancer screening; MRI - breast cancer screening ... is performed to screen women to detect early breast cancer when it is more likely to be cured. ...

  18. RBC Antibody Screen

    Science.gov (United States)

    ... C Cystic Fibrosis (CF) Gene Mutations Testing Cytomegalovirus (CMV) Tests D-dimer Dengue Fever Testing Des-gamma- ... Index of Screening Recommendations Not Listed? Not Listed? Newborn Screening Screening Tests for Infants Screening Tests for ...

  19. Technical Update: Preimplantation Genetic Diagnosis and Screening.

    Science.gov (United States)

    Dahdouh, Elias M; Balayla, Jacques; Audibert, François; Wilson, R Douglas; Audibert, François; Brock, Jo-Ann; Campagnolo, Carla; Carroll, June; Chong, Karen; Gagnon, Alain; Johnson, Jo-Ann; MacDonald, William; Okun, Nanette; Pastuck, Melanie; Vallée-Pouliot, Karine

    2015-05-01

    technologies. Preimplantation genetic diagnosis is an alternative to prenatal diagnosis for the detection of genetic disorders in couples at risk of transmitting a genetic condition to their offspring. Preimplantation genetic screening is being proposed to improve the effectiveness of in vitro fertilization by screening for embryonic aneuploidy. Though FISH-based PGS showed adverse effects on IVF success, emerging evidence from new studies using comprehensive chromosome screening technology appears promising. Recommendations 1. Before preimplantation genetic diagnosis is performed, genetic counselling must be provided by a certified genetic counsellor to ensure that patients fully understand the risk of having an affected child, the impact of the disease on an affected child, and the benefits and limitations of all available options for preimplantation and prenatal diagnosis. (III-A) 2. Couples should be informed that preimplantation genetic diagnosis can reduce the risk of conceiving a child with a genetic abnormality carried by one or both parents if that abnormality can be identified with tests performed on a single cell or on multiple trophectoderm cells. (II-2B) 3. Invasive prenatal or postnatal testing to confirm the results of preimplantation genetic diagnosis is encouraged because the methods used for preimplantation genetic diagnosis have technical limitations that include the possibility of a false result. (II-2B) 4. Trophectoderm biopsy has no measurable impact on embryo development, as opposed to blastomere biopsy. Therefore, whenever possible, trophectoderm biopsy should be the method of choice in embryo biopsy and should be performed by experienced hands. (I-B) 5. Preimplantation genetic diagnosis of single-gene disorders should ideally be performed with multiplex polymerase chain reaction coupled with trophectoderm biopsy whenever available. (II-2B) 6. The use of comprehensive chromosome screening technology coupled with trophectoderm biopsy in preimplantation

  20. A high-content subtractive screen for selecting small molecules affecting internalization of GPCRs

    CSIR Research Space (South Africa)

    Kwon, Y-J

    2012-03-01

    Full Text Available was screened against seven agonist-induced GPCR internalization cell models as well as transferrin uptake in human embryonic kidney cells. Molecules acting on a single receptor were identified through excluding pan-specific compounds affecting housekeeping...

  1. Health literacy screening instruments for eHealth applications: a systematic review.

    Science.gov (United States)

    Collins, Sarah A; Currie, Leanne M; Bakken, Suzanne; Vawdrey, David K; Stone, Patricia W

    2012-06-01

    To systematically review current health literacy (HL) instruments for use in consumer-facing and mobile health information technology screening and evaluation tools. The databases, PubMed, OVID, Google Scholar, Cochrane Library and Science Citation Index, were searched for health literacy assessment instruments using the terms "health", "literacy", "computer-based," and "psychometrics". All instruments identified by this method were critically appraised according to their reported psychometric properties and clinical feasibility. Eleven different health literacy instruments were found. Screening questions, such as asking a patient about his/her need for assistance in navigating health information, were evaluated in seven different studies and are promising for use as a valid, reliable, and feasible computer-based approach to identify patients that struggle with low health literacy. However, there was a lack of consistency in the types of screening questions proposed. There is also a lack of information regarding the psychometric properties of computer-based health literacy instruments. Only English language health literacy assessment instruments were reviewed and analyzed. Current health literacy screening tools demonstrate varying benefits depending on the context of their use. In many cases, it seems that a single screening question may be a reliable, valid, and feasible means for establishing health literacy. A combination of screening questions that assess health literacy and technological literacy may enable tailoring eHealth applications to user needs. Further research should determine the best screening question(s) and the best synthesis of various instruments' content and methodologies for computer-based health literacy screening and assessment. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. Health Literacy Screening Instruments for eHealth Applications: A Systematic Review

    Science.gov (United States)

    Collins, Sarah A.; Currie, Leanne M.; Bakken, Suzanne; Vawdrey, David K.; Stone, Patricia W.

    2012-01-01

    Objective To systematically review current health literacy (HL) instruments for use in consumer-facing and mobile health information technology screening and evaluation tools. Design The databases, PubMed, OVID, Google Scholar, Cochrane Library and Science Citation Index, were searched for health literacy assessment instruments using the terms “health”, “literacy”, “computer-based,” and “psychometrics”. All instruments identified by this method were critically appraised according to their reported psychometric properties and clinical feasibility. Results Eleven different health literacy instruments were found. Screening questions, such as asking a patient about his/her need for assistance in navigating health information, were evaluated in 7 different studies and are promising for use as a valid, reliable, and feasible computer-based approach to identify patients that struggle with low health literacy. However, there was a lack of consistency in the types of screening questions proposed. There is also a lack of information regarding the psychometric properties of computer-based health literacy instruments. Limitations Only English language health literacy assessment instruments were reviewed and analyzed. Conclusions Current health literacy screening tools demonstrate varying benefits depending on the context of their use. In many cases, it seems that a single screening question may be a reliable, valid, and feasible means for establishing health literacy. A combination of screening questions that assess health literacy and technological literacy may enable tailoring eHealth applications to user needs. Further research should determine the best screening question(s) and the best synthesis of various instruments’ content and methodologies for computer-based health literacy screening and assessment. PMID:22521719

  3. Fluorescence-based high-throughput screening of dicer cleavage activity.

    Science.gov (United States)

    Podolska, Katerina; Sedlak, David; Bartunek, Petr; Svoboda, Petr

    2014-03-01

    Production of small RNAs by ribonuclease III Dicer is a key step in microRNA and RNA interference pathways, which employ Dicer-produced small RNAs as sequence-specific silencing guides. Further studies and manipulations of microRNA and RNA interference pathways would benefit from identification of small-molecule modulators. Here, we report a study of a fluorescence-based in vitro Dicer cleavage assay, which was adapted for high-throughput screening. The kinetic assay can be performed under single-turnover conditions (35 nM substrate and 70 nM Dicer) in a small volume (5 µL), which makes it suitable for high-throughput screening in a 1536-well format. As a proof of principle, a small library of bioactive compounds was analyzed, demonstrating potential of the assay.

  4. Screening for retinopathy of prematurity: a report from upper Egypt

    Directory of Open Access Journals (Sweden)

    Mahmoud M. Nassar

    2016-02-01

    Full Text Available AIM: To detect the incidence of retinopathy of prematurity (ROP in a tertiary referral neonatal intensive care unit in upper Egypt and to describe the obstacles faced during implementing the screening protocol for the first time. METHODS: Consecutive infants were enrolled at birth and screened for ROP. We used the UK ROP guideline (May 2008 for infant selection, follow up and treatment. Repeat examinations were performed until retinal vascularisation was complete. RESULTS: Fifty-two infants were enrolled: 24 males and 28 females. Mean gestational age was 31.3wk (±2.8 SD and mean birth weight was 1234.6 g (±221.1 SD. Incidence of ROP was 36.5% (stages 1, 2, 3 and 4a were 9.6%, 9.6%, 15.4% and 1.9% respectively, no stages 4b or 5 were found in this series. Six infants (11.5% died during screening without ROP, 25 infants (48.1% were discharged from screening with retinal vascularisation reaching zone III, 5 infants (9.6% were treated with indirect diode with or without additional cryotherapy and 16 infants (30.8% were lost to follow up. In this series gestational age rather than birth weight was found significantly correlated and predictive (P<0.05 with ROP stages. CONCLUSION: ROP in a single site in Upper Egypt appears to have comparable incidence to other areas worldwide. The main screening obstacle was missing cases due to the absence of a national ROP screening protocol.

  5. Heterointerface Screening Effects between Organic Monolayers and Monolayer Transition Metal Dichalcogenides

    KAUST Repository

    Zheng, Yu Jie; Huang, Yu Li; Chen, Yifeng; Zhao, Weijie; Eda, Goki; Spataru, Catalin D.; Zhang, Wenjing; Chang, Yung-Huang; Li, Lain-Jong; Chi, Dongzhi; Quek, Su Ying; Wee, Andrew Thye Shen

    2016-01-01

    © 2016 American Chemical Society. The nature and extent of electronic screening at heterointerfaces and their consequences on energy level alignment are of profound importance in numerous applications, such as solar cells, electronics etc. The increasing availability of two-dimensional (2D) transition metal dichalcogenides (TMDs) brings additional opportunities for them to be used as interlayers in "van der Waals (vdW) heterostructures" and organic/inorganic flexible devices. These innovations raise the question of the extent to which the 2D TMDs participate actively in dielectric screening at the interface. Here we study perylene-3,4,9,10-tetracarboxylic dianhydride (PTCDA) monolayers adsorbed on single-layer tungsten diselenide (WSe2), bare graphite, and Au(111) surfaces, revealing a strong dependence of the PTCDA HOMO-LUMO gap on the electronic screening effects from the substrate. The monolayer WSe2 interlayer provides substantial, but not complete, screening at the organic/inorganic interface. Our results lay a foundation for the exploitation of the complex interfacial properties of hybrid systems based on TMD materials.

  6. Heterointerface Screening Effects between Organic Monolayers and Monolayer Transition Metal Dichalcogenides

    KAUST Repository

    Zheng, Yu Jie

    2016-01-21

    © 2016 American Chemical Society. The nature and extent of electronic screening at heterointerfaces and their consequences on energy level alignment are of profound importance in numerous applications, such as solar cells, electronics etc. The increasing availability of two-dimensional (2D) transition metal dichalcogenides (TMDs) brings additional opportunities for them to be used as interlayers in "van der Waals (vdW) heterostructures" and organic/inorganic flexible devices. These innovations raise the question of the extent to which the 2D TMDs participate actively in dielectric screening at the interface. Here we study perylene-3,4,9,10-tetracarboxylic dianhydride (PTCDA) monolayers adsorbed on single-layer tungsten diselenide (WSe2), bare graphite, and Au(111) surfaces, revealing a strong dependence of the PTCDA HOMO-LUMO gap on the electronic screening effects from the substrate. The monolayer WSe2 interlayer provides substantial, but not complete, screening at the organic/inorganic interface. Our results lay a foundation for the exploitation of the complex interfacial properties of hybrid systems based on TMD materials.

  7. Effects of doping and bias voltage on the screening in AAA-stacked trilayer graphene

    Science.gov (United States)

    Mohammadi, Yawar; Moradian, Rostam; Shirzadi Tabar, Farzad

    2014-09-01

    We calculate the static polarization of AAA-stacked trilayer graphene (TLG) and study its screening properties within the random phase approximation (RPA) in all undoped, doped and biased regimes. We find that the static polarization of undoped AAA-stacked TLG is a combination of the doped and undoped single-layer graphene static polarization. This leads to an enhancement of the dielectric background constant along a Thomas-Fermi screening with the Thomas-Fermi wave vector which is independent of carrier concentrations and a 1/r3 power law decay for the long-distance behavior of the screened Coulomb potential. We show that effects of a bias voltage can be taken into account by a renormalization of the interlayer hopping energy to a new bias-voltage-dependent value, indicating screening properties of AAA-stacked TLG can be tuned electrically. We also find that screening properties of doped AAA-stacked TLG, when μ exceeds √{2}γ, are similar to that of doped SLG only depending on doping. While for μ<√{2}γ, its screening properties are combination of SLG and AA-stacked bilayer graphene screening properties and they are determined by doping and the interlayer hopping energy.

  8. Cost-effectiveness of cervical-cancer screening in five developing countries.

    Science.gov (United States)

    Goldie, Sue J; Gaffikin, Lynne; Goldhaber-Fiebert, Jeremy D; Gordillo-Tobar, Amparo; Levin, Carol; Mahé, Cédric; Wright, Thomas C

    2005-11-17

    Cervical-cancer screening strategies that involve the use of conventional cytology and require multiple visits have been impractical in developing countries. We used computer-based models to assess the cost-effectiveness of a variety of cervical-cancer screening strategies in India, Kenya, Peru, South Africa, and Thailand. Primary data were combined with data from the literature to estimate age-specific incidence and mortality rates for cancer and the effectiveness of screening for and treatment of precancerous lesions. We assessed the direct medical, time, and program-related costs of strategies that differed according to screening test, targeted age and frequency, and number of clinic visits required. Single-visit strategies involved the assumption that screening and treatment could be provided in the same day. Outcomes included the lifetime risk of cancer, years of life saved, lifetime costs, and cost-effectiveness ratios (cost per year of life saved). The most cost-effective strategies were those that required the fewest visits, resulting in improved follow-up testing and treatment. Screening women once in their lifetime, at the age of 35 years, with a one-visit or two-visit screening strategy involving visual inspection of the cervix with acetic acid or DNA testing for human papillomavirus (HPV) in cervical cell samples, reduced the lifetime risk of cancer by approximately 25 to 36 percent, and cost less than 500 dollars per year of life saved. Relative cancer risk declined by an additional 40 percent with two screenings (at 35 and 40 years of age), resulting in a cost per year of life saved that was less than each country's per capita gross domestic product--a very cost-effective result, according to the Commission on Macroeconomics and Health. Cervical-cancer screening strategies incorporating visual inspection of the cervix with acetic acid or DNA testing for HPV in one or two clinical visits are cost-effective alternatives to conventional three

  9. A novel decision tree approach based on transcranial Doppler sonography to screen for blunt cervical vascular injuries.

    Science.gov (United States)

    Purvis, Dianna; Aldaghlas, Tayseer; Trickey, Amber W; Rizzo, Anne; Sikdar, Siddhartha

    2013-06-01

    Early detection and treatment of blunt cervical vascular injuries prevent adverse neurologic sequelae. Current screening criteria can miss up to 22% of these injuries. The study objective was to investigate bedside transcranial Doppler sonography for detecting blunt cervical vascular injuries in trauma patients using a novel decision tree approach. This prospective pilot study was conducted at a level I trauma center. Patients undergoing computed tomographic angiography for suspected blunt cervical vascular injuries were studied with transcranial Doppler sonography. Extracranial and intracranial vasculatures were examined with a portable power M-mode transcranial Doppler unit. The middle cerebral artery mean flow velocity, pulsatility index, and their asymmetries were used to quantify flow patterns and develop an injury decision tree screening protocol. Student t tests validated associations between injuries and transcranial Doppler predictive measures. We evaluated 27 trauma patients with 13 injuries. Single vertebral artery injuries were most common (38.5%), followed by single internal carotid artery injuries (30%). Compared to patients without injuries, mean flow velocity asymmetry was higher for single internal carotid artery (P = .003) and single vertebral artery (P = .004) injuries. Similarly, pulsatility index asymmetry was higher in single internal carotid artery (P = .015) and single vertebral artery (P = .042) injuries, whereas the lowest pulsatility index was elevated for bilateral vertebral artery injuries (P = .006). The decision tree yielded 92% specificity, 93% sensitivity, and 93% correct classifications. In this pilot feasibility study, transcranial Doppler measures were significantly associated with the blunt cervical vascular injury status, suggesting that transcranial Doppler sonography might be a viable bedside screening tool for trauma. Patient-specific hemodynamic information from transcranial Doppler assessment has the potential to alter

  10. Leptin gene polymorphism in Indian Sahiwal cattle by single strand ...

    African Journals Online (AJOL)

    These leptin gene variants can be sequenced and screened in the entire population to develop single nucleotide polymorphisms (SNPs) for association studies with different productive and reproductive performances and marker assisted selection. Keywords: Leptin gene, PCR-SSCP, genetic variability, dairy cattle

  11. FEPs Screening of Processes and Issues in Drip Shield and Waste Package Degradation

    International Nuclear Information System (INIS)

    K. Mon

    2004-01-01

    The purpose of this report is to evaluate and document the inclusion or exclusion of features, events and processes (FEPs) with respect to drip shield and waste package modeling used to support the Total System Performance Assessment for License Application (TSPA-LA). Thirty-three FEPs associated with the waste package and drip shield performance have been identified (DTN: MO0407SEPFEPLA.000 [DIRS 170760]). A screening decision, either ''included'' or ''excluded,'' has been assigned to each FEP, with the technical bases for screening decisions, as required by the Nuclear Regulatory Commission (NRC) in 10 CFR 63.114 (d, e, and f) [DIRS 156605]. The FEPs analyses in this report address issues related to the degradation and potential failure of the drip shield and waste package over the post closure regulatory period of 10,000 years after permanent closure. For included FEPs, this report summarizes the disposition of the FEP in TSPA-LA. For excluded FEPs, this report provides the technical bases for the screening arguments for exclusion from TSPA-LA. The analyses are for the TSPA-LA base-case design (BSC 2004 [DIRS 168489]), where a drip shield is placed over the waste package without backfill over the drip shield (BSC 2004 [DIRS 168489]). Each FEP includes one or more specific issues, collectively described by a FEP name and description. The FEP description encompasses a single feature, event, or process, or a few closely related or coupled processes, provided the entire FEP can be addressed by a single specific screening argument or TSPA-LA disposition. The FEPs were assigned to associated Project reports, so the screening decisions reside with the relevant subject-matter experts

  12. Using an FSDS-R Item to Screen for Sexually Related Distress: A MsFLASH Analysis

    Directory of Open Access Journals (Sweden)

    Janet S. Carpenter, PhD, RN, FAAN

    2015-03-01

    Conclusions: A single FSDS-R item may be a useful screening tool to quickly identify midlife women with sexually related distress when it is not feasible to administer the entire scale, though further validation is warranted. Carpenter JS, Reed SD, Guthrie KA, Larson JC, Newton KM, Lau RJ, Learman LA, and Shifren JL. Using an FSDS-R item to screen for sexually related distress: A MsFLASH analysis. Sex Med 2015;3:7–13.

  13. Prenatal screening and genetics

    DEFF Research Database (Denmark)

    Alderson, P; Aro, A R; Dragonas, T

    2001-01-01

    Although the term 'genetic screening' has been used for decades, this paper discusses how, in its most precise meaning, genetic screening has not yet been widely introduced. 'Prenatal screening' is often confused with 'genetic screening'. As we show, these terms have different meanings, and we...... examine definitions of the relevant concepts in order to illustrate this point. The concepts are i) prenatal, ii) genetic screening, iii) screening, scanning and testing, iv) maternal and foetal tests, v) test techniques and vi) genetic conditions. So far, prenatal screening has little connection...... with precisely defined genetics. There are benefits but also disadvantages in overstating current links between them in the term genetic screening. Policy making and professional and public understandings about screening could be clarified if the distinct meanings of prenatal screening and genetic screening were...

  14. Tuberculosis screening of travelers to higher-incidence countries: A cost-effectiveness analysis

    Directory of Open Access Journals (Sweden)

    Menzies Dick

    2008-06-01

    Full Text Available Abstract Background Travelers to countries with high tuberculosis incidence can acquire infection during travel. We sought to compare four screening interventions for travelers from low-incidence countries, who visit countries with varying tuberculosis incidence. Methods Decision analysis model: We considered hypothetical cohorts of 1,000 travelers, 21 years old, visiting Mexico, the Dominican Republic, or Haiti for three months. Travelers departed from and returned to the United States or Canada; they were born in the United States, Canada, or the destination countries. The time horizon was 20 years, with 3% annual discounting of future costs and outcomes. The analysis was conducted from the health care system perspective. Screening involved tuberculin skin testing (post-travel in three strategies, with baseline pre-travel tests in two, or chest radiography post-travel (one strategy. Returning travelers with tuberculin conversion (one strategy or other evidence of latent tuberculosis (three strategies were offered treatment. The main outcome was cost (in 2005 US dollars per tuberculosis case prevented. Results For all travelers, a single post-trip tuberculin test was most cost-effective. The associated cost estimate per case prevented ranged from $21,406 for Haitian-born travelers to Haiti, to $161,196 for US-born travelers to Mexico. In all sensitivity analyses, the single post-trip tuberculin test remained most cost-effective. For US-born travelers to Haiti, this strategy was associated with cost savings for trips over 22 months. Screening was more cost-effective with increasing trip duration and infection risk, and less so with poorer treatment adherence. Conclusion A single post-trip tuberculin skin test was the most cost-effective strategy considered, for travelers from the United States or Canada. The analysis did not evaluate the use of interferon-gamma release assays, which would be most relevant for travelers who received BCG

  15. Do recent epidemiologic observations impact who and how we should screen for CRC?

    Science.gov (United States)

    Bortniker, Ethan; Anderson, Joseph C

    2015-03-01

    Colorectal cancer (CRC) screening is recommended to begin at age 50 for those patients with no significant family history of CRC. However, even within this group of average-risk patients, there is data to suggest that there may be variation in CRC risk. These observations suggest that perhaps CRC screening should be tailored to target those patients at higher risk for earlier or more invasive screening as compared to those individuals at lower risk. The strategy of how to identify those higher-risk patients may not be straightforward. One method might be to use single risk factors such as smoking or elevated BMI as has been suggested in the recent American College of Gastroenterology CRC screening guidelines. Another paradigm involves the use of models which incorporate several risk factors to stratify patients by risk. This article will highlight recent large studies that examine recognized CRC risk factors as well as review recently developed CRC risk models. There will also be a discussion of the application of these factors and models in an effort to make CRC screening more efficient.

  16. [First trimester screening for Down syndrome at Prima facie. A 6-year survey].

    Science.gov (United States)

    Roth, P; Bernard, J-P; Meyer, V; Beaujard, M-P; Salomon, L-J; Ville, Y

    2016-02-01

    To evaluate the results of screening for trisomy 21 by the combined risk of first trimester (as defined by the decree of June 23, 2009) in the Prima facie structure. Single center study involving all patients that were seen for first trimester screening at Prima facie with singleton living pregnancy, not obtained by embryo donation, between 1 January 2009 and 31 December 2014. Eighteen thousand two hundred and fifty-one patients were included, of which underwent screening for trisomy 21 by the combined risk. One thousand and forty-six (6.1%) had a calculated risk higher than 1/250. Seventy-five were affected by trisomy 21, of whom 65 in the high risk group. The sensitivity and specificity of screening are 86.7% and 94.4%. The median nuchal translucency was 0.98 MoM. Screening for trisomy 21 by calculating the combined risk of first trimester enabled to detect 86.7% of trisomy 21 with a false positive rate of 5.6%. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  17. Local-global classifier fusion for screening chest radiographs

    Science.gov (United States)

    Ding, Meng; Antani, Sameer; Jaeger, Stefan; Xue, Zhiyun; Candemir, Sema; Kohli, Marc; Thoma, George

    2017-03-01

    Tuberculosis (TB) is a severe comorbidity of HIV and chest x-ray (CXR) analysis is a necessary step in screening for the infective disease. Automatic analysis of digital CXR images for detecting pulmonary abnormalities is critical for population screening, especially in medical resource constrained developing regions. In this article, we describe steps that improve previously reported performance of NLM's CXR screening algorithms and help advance the state of the art in the field. We propose a local-global classifier fusion method where two complementary classification systems are combined. The local classifier focuses on subtle and partial presentation of the disease leveraging information in radiology reports that roughly indicates locations of the abnormalities. In addition, the global classifier models the dominant spatial structure in the gestalt image using GIST descriptor for the semantic differentiation. Finally, the two complementary classifiers are combined using linear fusion, where the weight of each decision is calculated by the confidence probabilities from the two classifiers. We evaluated our method on three datasets in terms of the area under the Receiver Operating Characteristic (ROC) curve, sensitivity, specificity and accuracy. The evaluation demonstrates the superiority of our proposed local-global fusion method over any single classifier.

  18. Evaluation of undoped ZnS single crystal materials for x-ray imaging applications

    Science.gov (United States)

    Saleh, Muad; Lynn, Kelvin G.; McCloy, John S.

    2017-05-01

    ZnS-based materials have a long history of use as x-ray luminescent materials. ZnS was one of the first discovered scintillators and is reported to have one of the highest scintillator efficiencies. The use of ZnS for high energy luminescence has been thus far limited to thin powder screens, such as ZnS:Ag which is used for detecting alpha radiation, due to opacity to its scintillation light, primarily due to scattering. ZnS in bulk form (chemical vapor deposited, powder processed, and single crystal) has high transmission and low scattering compared to powder screens. In this paper, the performance of single crystalline ZnS is evaluated for low energy x-ray (PLE) of several undoped ZnS single crystals is compared to their Radioluminescence (RL) spectra. It was found that the ZnS emission wavelength varies on the excitation source energy.

  19. Cost-effectiveness of one versus two sample faecal immunochemical testing for colorectal cancer screening.

    Science.gov (United States)

    Goede, S Lucas; van Roon, Aafke H C; Reijerink, Jacqueline C I Y; van Vuuren, Anneke J; Lansdorp-Vogelaar, Iris; Habbema, J Dik F; Kuipers, Ernst J; van Leerdam, Monique E; van Ballegooijen, Marjolein

    2013-05-01

    The sensitivity and specificity of a single faecal immunochemical test (FIT) are limited. The performance of FIT screening can be improved by increasing the screening frequency or by providing more than one sample in each screening round. This study aimed to evaluate if two-sample FIT screening is cost-effective compared with one-sample FIT. The MISCAN-colon microsimulation model was used to estimate costs and benefits of strategies with either one or two-sample FIT screening. The FIT cut-off level varied between 50 and 200 ng haemoglobin/ml, and the screening schedule was varied with respect to age range and interval. In addition, different definitions for positivity of the two-sample FIT were considered: at least one positive sample, two positive samples, or the mean of both samples being positive. Within an exemplary screening strategy, biennial FIT from the age of 55-75 years, one-sample FIT provided 76.0-97.0 life-years gained (LYG) per 1000 individuals, at a cost of € 259,000-264,000 (range reflects different FIT cut-off levels). Two-sample FIT screening with at least one sample being positive provided 7.3-12.4 additional LYG compared with one-sample FIT at an extra cost of € 50,000-59,000. However, when all screening intervals and age ranges were considered, intensifying screening with one-sample FIT provided equal or more LYG at lower costs compared with two-sample FIT. If attendance to screening does not differ between strategies it is recommended to increase the number of screening rounds with one-sample FIT screening, before considering increasing the number of FIT samples provided per screening round.

  20. 3D mosquito screens to create window double screen traps for mosquito control.

    Science.gov (United States)

    Khattab, Ayman; Jylhä, Kaisa; Hakala, Tomi; Aalto, Mikko; Malima, Robert; Kisinza, William; Honkala, Markku; Nousiainen, Pertti; Meri, Seppo

    2017-08-29

    Mosquitoes are vectors for many diseases such as malaria. Insecticide-treated bed nets and indoor residual spraying of insecticides are the principal malaria vector control tools used to prevent malaria in the tropics. Other interventions aim at reducing man-vector contact. For example, house screening provides additive or synergistic effects to other implemented measures. We used commercial screen materials made of polyester, polyethylene or polypropylene to design novel mosquito screens that provide remarkable additional benefits to those commonly used in house screening. The novel design is based on a double screen setup made of a screen with 3D geometric structures parallel to a commercial mosquito screen creating a trap between the two screens. Owing to the design of the 3D screen, mosquitoes can penetrate the 3D screen from one side but cannot return through the other side, making it a unidirectional mosquito screen. Therefore, the mosquitoes are trapped inside the double screen system. The permissiveness of both sides of the 3D screens for mosquitoes to pass through was tested in a wind tunnel using the insectary strain of Anopheles stephensi. Among twenty-five tested 3D screen designs, three designs from the cone, prism, or cylinder design groups were the most efficient in acting as unidirectional mosquito screens. The three cone-, prism-, and cylinder-based screens allowed, on average, 92, 75 and 64% of Anopheles stephensi mosquitoes released into the wind tunnel to penetrate the permissive side and 0, 0 and 6% of mosquitoes to escape through the non-permissive side, respectively. A cone-based 3D screen fulfilled the study objective. It allowed capturing 92% of mosquitoes within the double screen setup inside the wind tunnel and blocked 100% from escaping. Thus, the cone-based screen effectively acted as a unidirectional mosquito screen. This 3D screen-based trap design could therefore be used in house screening as a means of avoiding infective bites and

  1. Packaging health services when resources are limited: the example of a cervical cancer screening visit.

    Directory of Open Access Journals (Sweden)

    Jane J Kim

    2006-11-01

    Full Text Available Increasing evidence supporting the value of screening women for cervical cancer once in their lifetime, coupled with mounting interest in scaling up successful screening demonstration projects, present challenges to public health decision makers seeking to take full advantage of the single-visit opportunity to provide additional services. We present an analytic framework for packaging multiple interventions during a single point of contact, explicitly taking into account a budget and scarce human resources, constraints acknowledged as significant obstacles for provision of health services in poor countries.We developed a binary integer programming (IP model capable of identifying an optimal package of health services to be provided during a single visit for a particular target population. Inputs to the IP model are derived using state-transition models, which compute lifetime costs and health benefits associated with each intervention. In a simplified example of a single lifetime cervical cancer screening visit, we identified packages of interventions among six diseases that maximized disability-adjusted life years (DALYs averted subject to budget and human resource constraints in four resource-poor regions. Data were obtained from regional reports and surveys from the World Health Organization, international databases, the published literature, and expert opinion. With only a budget constraint, interventions for depression and iron deficiency anemia were packaged with cervical cancer screening, while the more costly breast cancer and cardiovascular disease interventions were not. Including personnel constraints resulted in shifting of interventions included in the package, not only across diseases but also between low- and high-intensity intervention options within diseases.The results of our example suggest several key themes: Packaging other interventions during a one-time visit has the potential to increase health gains; the shortage of

  2. From structure prediction to genomic screens for novel non-coding RNAs

    DEFF Research Database (Denmark)

    Gorodkin, Jan; Hofacker, Ivo L.

    2011-01-01

    Abstract: Non-coding RNAs (ncRNAs) are receiving more and more attention not only as an abundant class of genes, but also as regulatory structural elements (some located in mRNAs). A key feature of RNA function is its structure. Computational methods were developed early for folding and prediction....... This and the increased amount of available genomes have made it possible to employ structure-based methods for genomic screens. The field has moved from folding prediction of single sequences to computational screens for ncRNAs in genomic sequence using the RNA structure as the main characteristic feature. Whereas early...... upon some of the concepts in current methods that have been applied in genomic screens for de novo RNA structures in searches for novel ncRNA genes and regulatory RNA structure on mRNAs. We discuss the strengths and weaknesses of the different strategies and how they can complement each other....

  3. Cancer screening guidelines.

    Science.gov (United States)

    Zoorob, R; Anderson, R; Cefalu, C; Sidani, M

    2001-03-15

    Numerous medical organizations have developed cancer screening guidelines. Faced with the broad, and sometimes conflicting, range of recommendations for cancer screening, family physicians must determine the most reasonable and up-to-date method of screening. Major medical organizations have generally achieved consensus on screening guidelines for breast, cervical and colorectal cancer. For breast cancer screening in women ages 50 to 70, clinical breast examination and mammography are generally recommended every one or two years, depending on the medical organization. For cervical cancer screening, most organizations recommend a Papanicolaou test and pelvic examination at least every three years in patients between 20 and 65 years of age. Annual fecal occult blood testing along with flexible sigmoidoscopy at five-year to 10-year intervals is the standard recommendation for colorectal cancer screening in patients older than 50 years. Screening for prostate cancer remains a matter of debate. Some organizations recommend digital rectal examination and a serum prostate-specific antigen test for men older than 50 years, while others do not. In the absence of compelling evidence to indicate a high risk of endometrial cancer, lung cancer, oral cancer and ovarian cancer, almost no medical organizations have developed cancer screening guidelines for these types of cancer.

  4. Development of a novel single tube nested PCR for enhanced detection of cytomegalovirus DNA from dried blood spots.

    Science.gov (United States)

    Atkinson, C; Emery, V C; Griffiths, P D

    2014-02-01

    Newborn screening for congenital cytomegalovirus (CCMV) using dried blood spots (DBS) has been proposed because many developed countries have DBS screening programmes in place for other diseases. The aim of this study was to develop a rapid, single tube nested polymerase chain reaction (PCR) method for enhanced detection of CMV from DBS compared to existing (single target) real time PCRs. The new method was compared with existing real time PCRs for sensitivity and specificity. Overall sensitivity of the single target PCR assays in both asymptomatic and symptomatic infants with laboratory confirmed congenital CMV was 69% (CMV PCR or culture positive before day 21 of life). In contrast, the single tube nested assay had an increased sensitivity of 81% with100% specificity. Overall the assay detected CMV from a DBS equivalent to an original blood sample which contained 500IU/ml. In conclusion this single tube nested methodology allows simultaneous amplification and detection of CMV DNA in 1.5h removing the associated contamination risk of a two step nested PCR. Owing to its increased sensitivity, it has the potential to be used as a screening assay and ultimately allow early identification and intervention for children with congenital CMV. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Chromium and molybdenum diffusion in tungsten single crystals

    International Nuclear Information System (INIS)

    Klotsman, S.M.; Koloskov, V.M.; Osetrov, S.V.; Polikarpova, I.P.; Tatarinova, G.N.; Timofeev, A.N.

    1989-01-01

    Consideration is given to results of measuring temperature dependences of diffusion coefficients of homovalent impurities of chromium and molybdenum in tungsten single crystals. It is concluded that the difference of activation energies of selfdiffusion and impurity diffusion in the system 'tungsten-homovalent impurity' is conditioned by interaction of screened potentials of impurity and vacancy with Lazarus-Le Claire model

  6. An effective docking strategy for virtual screening based on multi-objective optimization algorithm

    Directory of Open Access Journals (Sweden)

    Kang Ling

    2009-02-01

    Full Text Available Abstract Background Development of a fast and accurate scoring function in virtual screening remains a hot issue in current computer-aided drug research. Different scoring functions focus on diverse aspects of ligand binding, and no single scoring can satisfy the peculiarities of each target system. Therefore, the idea of a consensus score strategy was put forward. Integrating several scoring functions, consensus score re-assesses the docked conformations using a primary scoring function. However, it is not really robust and efficient from the perspective of optimization. Furthermore, to date, the majority of available methods are still based on single objective optimization design. Results In this paper, two multi-objective optimization methods, called MOSFOM, were developed for virtual screening, which simultaneously consider both the energy score and the contact score. Results suggest that MOSFOM can effectively enhance enrichment and performance compared with a single score. For three different kinds of binding sites, MOSFOM displays an excellent ability to differentiate active compounds through energy and shape complementarity. EFMOGA performed particularly well in the top 2% of database for all three cases, whereas MOEA_Nrg and MOEA_Cnt performed better than the corresponding individual scoring functions if the appropriate type of binding site was selected. Conclusion The multi-objective optimization method was successfully applied in virtual screening with two different scoring functions that can yield reasonable binding poses and can furthermore, be ranked with the potentially compromised conformations of each compound, abandoning those conformations that can not satisfy overall objective functions.

  7. Micropillar arrays as a high-throughput screening platform for therapeutics in multiple sclerosis.

    Science.gov (United States)

    Mei, Feng; Fancy, Stephen P J; Shen, Yun-An A; Niu, Jianqin; Zhao, Chao; Presley, Bryan; Miao, Edna; Lee, Seonok; Mayoral, Sonia R; Redmond, Stephanie A; Etxeberria, Ainhoa; Xiao, Lan; Franklin, Robin J M; Green, Ari; Hauser, Stephen L; Chan, Jonah R

    2014-08-01

    Functional screening for compounds that promote remyelination represents a major hurdle in the development of rational therapeutics for multiple sclerosis. Screening for remyelination is problematic, as myelination requires the presence of axons. Standard methods do not resolve cell-autonomous effects and are not suited for high-throughput formats. Here we describe a binary indicant for myelination using micropillar arrays (BIMA). Engineered with conical dimensions, micropillars permit resolution of the extent and length of membrane wrapping from a single two-dimensional image. Confocal imaging acquired from the base to the tip of the pillars allows for detection of concentric wrapping observed as 'rings' of myelin. The platform is formatted in 96-well plates, amenable to semiautomated random acquisition and automated detection and quantification. Upon screening 1,000 bioactive molecules, we identified a cluster of antimuscarinic compounds that enhance oligodendrocyte differentiation and remyelination. Our findings demonstrate a new high-throughput screening platform for potential regenerative therapeutics in multiple sclerosis.

  8. Fast and flexible selection with a single switch.

    Directory of Open Access Journals (Sweden)

    Tamara Broderick

    Full Text Available Selection methods that require only a single-switch input, such as a button click or blink, are potentially useful for individuals with motor impairments, mobile technology users, and individuals wishing to transmit information securely. We present a single-switch selection method, "Nomon," that is general and efficient. Existing single-switch selection methods require selectable options to be arranged in ways that limit potential applications. By contrast, traditional operating systems, web browsers, and free-form applications (such as drawing place options at arbitrary points on the screen. Nomon, however, has the flexibility to select any point on a screen. Nomon adapts automatically to an individual's clicking ability; it allows a person who clicks precisely to make a selection quickly and allows a person who clicks imprecisely more time to make a selection without error. Nomon reaps gains in information rate by allowing the specification of beliefs (priors about option selection probabilities and by avoiding tree-based selection schemes in favor of direct (posterior inference. We have developed both a Nomon-based writing application and a drawing application. To evaluate Nomon's performance, we compared the writing application with a popular existing method for single-switch writing (row-column scanning. Novice users wrote 35% faster with the Nomon interface than with the scanning interface. An experienced user (author TB, with 10 hours practice wrote at speeds of 9.3 words per minute with Nomon, using 1.2 clicks per character and making no errors in the final text.

  9. An Improved On-line Contingency Screening for Power System Transient Stability Assessment

    DEFF Research Database (Denmark)

    Weckesser, Johannes Tilman Gabriel; Jóhannsson, Hjörtur; Glavic, Mevludin

    2017-01-01

    This paper presents a contingency screening method and a framework for its on-line implementation. The proposed method carries out contingency screening and on-line stability assessment with respect to first-swing transient stability. For that purpose, it utilizes the single machine equivalent...... method and aims at improving the prior developed contingency screening approaches. In order to determine vulnerability of the system with respect to a particular contingency, only one time-domain simulation needs to be performed. An early stop criteria is proposed so that in a majority of the cases...... the simulation can be terminated after a few hundred milliseconds of simulated system response. The method's outcome is an assessment of the system's stability and a classification of each considered contingency. The contingencies are categorized by exploiting parameters of an equivalent one machine infinite bus...

  10. Performance evaluation of phage-displayed synthetic human single-domain antibody libraries: A retrospective analysis.

    Science.gov (United States)

    Henry, Kevin A; Tanha, Jamshid

    2018-05-01

    Fully human synthetic single-domain antibodies (sdAbs) are desirable therapeutic molecules but their development is a considerable challenge. Here, using a retrospective analysis of in-house historical data, we examined the parameters that impact the outcome of screening phage-displayed synthetic human sdAb libraries to discover antigen-specific binders. We found no evidence for a differential effect of domain type (V H or V L ), library randomization strategy, incorporation of a stabilizing disulfide linkage or sdAb display format (monovalent vs. multivalent) on the probability of obtaining any antigen-binding human sdAbs, instead finding that the success of library screens was primarily related to properties of target antigens, especially molecular mass. The solubility and binding affinity of sdAbs isolated from successful screens depended both on properties of the sdAb libraries (primarily domain type) and the target antigens. Taking attrition of sdAbs with major manufacturability concerns (aggregation; low expression) and sdAbs that do not recognize native cell-surface antigens as independent probabilities, we calculate the overall likelihood of obtaining ≥1 antigen-binding human sdAb from a single library-target screen as ~24%. Successful library-target screens should be expected to yield ~1.3 human sdAbs on average, each with average binding affinity of ~2 μM. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. FEPs Screening of Processes and Issues in Drip Shield and Waste Package Degradation

    Energy Technology Data Exchange (ETDEWEB)

    K. Mon

    2004-10-11

    The purpose of this report is to evaluate and document the inclusion or exclusion of features, events and processes (FEPs) with respect to drip shield and waste package modeling used to support the Total System Performance Assessment for License Application (TSPA-LA). Thirty-three FEPs associated with the waste package and drip shield performance have been identified (DTN: MO0407SEPFEPLA.000 [DIRS 170760]). A screening decision, either ''included'' or ''excluded,'' has been assigned to each FEP, with the technical bases for screening decisions, as required by the Nuclear Regulatory Commission (NRC) in 10 CFR 63.114 (d, e, and f) [DIRS 156605]. The FEPs analyses in this report address issues related to the degradation and potential failure of the drip shield and waste package over the post closure regulatory period of 10,000 years after permanent closure. For included FEPs, this report summarizes the disposition of the FEP in TSPA-LA. For excluded FEPs, this report provides the technical bases for the screening arguments for exclusion from TSPA-LA. The analyses are for the TSPA-LA base-case design (BSC 2004 [DIRS 168489]), where a drip shield is placed over the waste package without backfill over the drip shield (BSC 2004 [DIRS 168489]). Each FEP includes one or more specific issues, collectively described by a FEP name and description. The FEP description encompasses a single feature, event, or process, or a few closely related or coupled processes, provided the entire FEP can be addressed by a single specific screening argument or TSPA-LA disposition. The FEPs were assigned to associated Project reports, so the screening decisions reside with the relevant subject-matter experts.

  12. An Algorithm for Glaucoma Screening in Clinical Settings and Its Preliminary Performance Profile

    Directory of Open Access Journals (Sweden)

    S-Farzad Mohammadi

    2013-01-01

    Full Text Available Purpose: To devise and evaluate a screening algorithm for glaucoma in clinical settings. Methods: Screening included examination of the optic disc for vertical cupping (≥0.4 and asymmetry (≥0.15, Goldmann applanation tonometry (≥21 mmHg, adjusted or unadjusted for central corneal thickness, and automated perimetry. In the diagnostic step, retinal nerve fiber layer imaging was performed using scanning laser polarimetry. Performance of the screening protocol was assessed in an eye hospital-based program in which 124 non-physician personnel aged 40 years or above were examined. A single ophthalmologist carried out the examinations and in equivocal cases, a glaucoma subspecialist′s opinion was sought. Results: Glaucoma was diagnosed in six cases (prevalence 4.8%; 95% confidence interval, 0.01-0.09 of whom five were new. The likelihood of making a definite diagnosis of glaucoma for those who were screened positively was 8.5 times higher than the estimated baseline risk for the reference population; the positive predictive value of the screening protocol was 30%. Screening excluded 80% of the initial population. Conclusion: Application of a formal screening protocol (such as our algorithm or its equivalent in clinical settings can be helpful in detecting new cases of glaucoma. Preliminary performance assessment of the algorithm showed its applicability and effectiveness in detecting glaucoma among subjects without any visual complaint.

  13. Microdissection and molecular manipulation of single chromosomes in woody fruit trees with small chromosomes using pomelo (Citrus grandis) as a model. II. Cloning of resistance gene analogs from single chromosomes.

    Science.gov (United States)

    Huang, D; Wu, W; Lu, L

    2004-05-01

    Amplification of resistance gene analogs (RGAs) is both a useful method for acquiring DNA markers closely linked to disease resistance (R) genes and a potential approach for the rapid cloning of R genes in plants. However, the screening of target sequences from among the numerous amplified RGAs can be very laborious. The amplification of RGAs from specific chromosomes could greatly reduce the number of RGAs to be screened and, consequently, speed up the identification of target RGAs. We have developed two methods for amplifying RGAs from single chromosomes. Method 1 uses products of Sau3A linker adaptor-mediated PCR (LAM-PCR) from a single chromosome as the templates for RGA amplification, while Method 2 directly uses a single chromosomal DNA molecule as the template. Using a pair of degenerate primers designed on the basis of the conserved nucleotide-binding-site motifs in many R genes, RGAs were successfully amplified from single chromosomes of pomelo using both these methods. Sequencing and cluster analysis of RGA clones obtained from single chromosomes revealed the number, type and organization of R-gene clusters on the chromosomes. We suggest that Method 1 is suitable for analyzing chromosomes that are unidentifiable under a microscope, while Method 2 is more appropriate when chromosomes can be clearly identified.

  14. STRP Screening Sets for the human genome at 5 cM density

    Directory of Open Access Journals (Sweden)

    Marth Gabor

    2003-02-01

    Full Text Available Abstract Background Short tandem repeat polymorphisms (STRPs are powerful tools for gene mapping and other applications. A STRP genome scan of 10 cM is usually adequate for mapping single gene disorders. However mapping studies involving genetically complex disorders and especially association (linkage disequilibrium often require higher STRP density. Results We report the development of two separate 10 cM human STRP Screening Sets (Sets 12 and 52 which span all chromosomes. When combined, the two Sets contain a total of 782 STRPs, with average STRP spacing of 4.8 cM, average heterozygosity of 0.72, and total sex-average coverage of 3535 cM. The current Sets are comprised almost entirely of STRPs based on tri- and tetranucleotide repeats. We also report correction of primer sequences for many STRPs used in previous Screening Sets. Detailed information for the new Screening Sets is available from our web site: http://research.marshfieldclinic.org/genetics. Conclusion Our new human STRP Screening Sets will improve the quality and cost effectiveness of genotyping for gene mapping and other applications.

  15. Galactomannan and Polymerase Chain Reaction-Based Screening for Invasive Aspergillosis Among High-Risk Hematology Patients: A Diagnostic Meta-analysis.

    Science.gov (United States)

    Arvanitis, Marios; Anagnostou, Theodora; Mylonakis, Eleftherios

    2015-10-15

    Screening of high-risk patients for invasive aspergillosis (IA) has the potential to decrease the use of empiric antifungal agents. However, the performance of different screening methods has not been studied. We performed a meta-analysis of published studies to assess the diagnostic performance of galactomannan (GM) and polymerase chain reaction (PCR) as weekly screening tests in high-risk populations. The sensitivity and specificity of 6 approaches combining GM and PCR were estimated using the bivariate model. Thirteen studies with 1670 patients met our inclusion criteria. Single positive test results had modest sensitivity and specificity for screening (respectively, 92% and 90% for GM; 84% and 76% for PCR). The screening approach with the highest sensitivity was the one that used at least 1 GM- or PCR-positive result to define a positive episode, achieving a sensitivity of 99%, significantly higher than any single test (P = .0018 compared with GM and P value of 100%, whereas the presence of at least 2 positive results is highly suggestive of an active infection with a positive predictive value of 88%. © The Author 2015. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  16. Strategies of digital fundus photography for screening diabetic retinopathy in a diabetic population in urban China.

    Science.gov (United States)

    Ding, Jiyuan; Zou, Yanhong; Liu, Ningpu; Jiang, Li; Ren, Xuetao; Jia, Wei; Snellingen, Torkel; Chongsuvivatwong, Virasakdi; Liu, Xipu

    2012-12-01

    To evaluate the effect of mydriasis and different field strategies on technical failure, probability to refer diabetic retinopathy (DR, sensitivity) and probability not to refer patients without DR (specificity) of digital photography in screening with a fundus camera. A total of 531 patients with diabetes underwent fundus photography with cross-combinations of mydriasis/nonmydriasis and single-field/two-field strategies, followed by slit lamp biomicroscopic examination by a trained ophthalmologist. Fundus photographs were graded independently by another experienced ophthalmologist. Calculations were first based on cases with non-gradable images treated as being referred and then with them excluded. Percentages of DR and referable DR in this patient cohort were 22.4% and 7.7%, respectively, based on slit lamp biomicroscopic examination. Mydriasis significantly reduced the technical failure rate from 27.1% to 8.3% under a single-field strategy, and from 28.2% to 8.9% under a two-field strategy. As compared to the single-field strategy, the two-field strategy increased sensitivity from 75.6% to 87.8% without mydriasis and from 73.2% to 90.2% with mydriasis. Mydriasis increased specificity from 68.8% to 84.3% in the single-field strategy and from 64.7% to 81.6% in the two-field strategy. Had the subjects with non-gradable images been excluded, the two-field strategy without mydriasis reported sensitivity of 85.7% and specificity of 91.6%. Both mydriasis and the two-field strategy are useful in photographic screening tests. Technical failure should be taken into consideration when screening strategies for DR are determined.

  17. Screening for colorectal cancer.

    Science.gov (United States)

    He, Jin; Efron, Jonathan E

    2011-01-01

    March is national colorectal cancer awareness month. It is estimated that as many as 60% of colorectal cancer deaths could be prevented if all men and women aged 50 years or older were screened routinely. In 2000, Katie Couric's televised colonoscopy led to a 20% increase in screening colonoscopies across America, a stunning rise called the "Katie Couric Effect". This event demonstrated how celebrity endorsement affects health behavior. Currently, discussion is ongoing about the optimal strategy for CRC screening, particularly the costs of screening colonoscopy. The current CRC screening guidelines are summarized in Table 2. Debates over the optimum CRC screening test continue in the face of evidence that 22 million Americans aged 50 to 75 years are not screened for CRC by any modality and 25,000 of those lives may have been saved if they had been screened for CRC. It is clear that improving screening rates and reducing disparities in underscreened communities and population subgroups could further reduce colorectal cancer morbidity and mortality. National Institutes of Health consensus identified the following priority areas to enhance the use and quality of colorectal cancer screening: Eliminate financial barriers to colorectal cancer screening and appropriate follow-up of positive results of colorectal cancer screening. Develop systems to ensure the high quality of colorectal cancer screening programs. Conduct studies to determine the comparative effectiveness of the various colorectal cancer screening methods in usual practice settings. Encouraging population adherence to screening tests and allowing patients to select the tests they prefer may do more good (as long as they choose something) than whatever procedure is chosen by the medical profession as the preferred test.

  18. Skin Cancer Screening

    Science.gov (United States)

    ... Genetics of Skin Cancer Skin Cancer Screening Research Skin Cancer Screening (PDQ®)–Patient Version What is screening? ... These are called diagnostic tests . General Information About Skin Cancer Key Points Skin cancer is a disease ...

  19. Premenstrual mood and empathy after a single light therapy session

    NARCIS (Netherlands)

    aan het Rot, Marije; Miloserdov, Kristina; Buijze, Anna L. F.; Meesters, Ybe; Gordijn, Marijke C. M.

    2017-01-01

    To examine whether acute changes in cognitive empathy might mediate the impact of light therapy on mood, we assessed the effects of a single light-therapy session on mood and cognitive empathy in 48 premenstrual women, including 17 who met Premenstrual Symptoms Screening Tool criteria for

  20. Screening for Cancer

    Science.gov (United States)

    Cancer screening is checking for cancer in people who don't have symptoms. Screening tests can help doctors find and treat several types of cancer early, but cancer screening can have harms as well as benefits.

  1. Domestic violence screening in a military setting: provider screening and attitudes.

    Science.gov (United States)

    Lutgendorf, Monica; Busch, Jeanne; Magann, Everett F; Morrison, John C

    2010-06-01

    Domestic violence is an important healthcare problem, and it appears more prevalent in military patient populations although no one has demonstrated the cause behind this phenomenon. The purpose of this observational study was to assess data regarding domestic violence screening from practitioners at one military training center. This study used an anonymous questionnaire for physicians, nurses and nurse midwives, which surveyed current methods, attitudes toward screening, and barriers for such assessment. Fifty-seven surveys were distributed, and 26 were returned for a response rate of 45.6%. Only about a third (38.5%) of the practitioners screened all obstetric patients while the remainder screened selected patients for domestic violence. Even less (19%) screened gynecology patients routinely, whereas 69% reported they screened selected women with chronic or somatic complaints. A history of prior abuse in the respondents led practitioners to try to identify such patients within their practice. Lack of education or training was the most common barrier to universal screening followed by time constraints and frustration about not being able to address adequately the problem when noted. These results emphasized the importance of an educational program to increase domestic violence awareness and routine screening.

  2. Active Learning Strategies for Phenotypic Profiling of High-Content Screens.

    Science.gov (United States)

    Smith, Kevin; Horvath, Peter

    2014-06-01

    High-content screening is a powerful method to discover new drugs and carry out basic biological research. Increasingly, high-content screens have come to rely on supervised machine learning (SML) to perform automatic phenotypic classification as an essential step of the analysis. However, this comes at a cost, namely, the labeled examples required to train the predictive model. Classification performance increases with the number of labeled examples, and because labeling examples demands time from an expert, the training process represents a significant time investment. Active learning strategies attempt to overcome this bottleneck by presenting the most relevant examples to the annotator, thereby achieving high accuracy while minimizing the cost of obtaining labeled data. In this article, we investigate the impact of active learning on single-cell-based phenotype recognition, using data from three large-scale RNA interference high-content screens representing diverse phenotypic profiling problems. We consider several combinations of active learning strategies and popular SML methods. Our results show that active learning significantly reduces the time cost and can be used to reveal the same phenotypic targets identified using SML. We also identify combinations of active learning strategies and SML methods which perform better than others on the phenotypic profiling problems we studied. © 2014 Society for Laboratory Automation and Screening.

  3. Formation and evolution of bubbly screens in confined oscillating bubbly liquids

    Science.gov (United States)

    Shklyaev, Sergey; Straube, Arthur V.

    2010-01-01

    We consider the dynamics of dilute monodisperse bubbly liquid confined by two plane solid walls and subject to small-amplitude high-frequency oscillations normal to the walls. The initial state corresponds to the uniform distribution of bubbles and motionless liquid. The period of external driving is assumed much smaller than typical relaxation times for a single bubble but larger than the period of volume eigenoscillations. The time-averaged description accounting for the two-way coupling between the liquid and the bubbles is applied. We show that the model predicts accumulation of bubbles in thin sheets parallel to the walls. These singular structures, which are formally characterized by infinitely thin width and infinitely high concentration, are referred to as bubbly screens. The formation of a bubbly screen is described analytically in terms of a self-similar solution, which is in agreement with numerical simulations. We study the evolution of bubbly screens and detect a one-dimensional stationary state, which is shown to be unconditionally unstable.

  4. Colorectal Cancer Screening

    Science.gov (United States)

    ... Genetics of Colorectal Cancer Colorectal Cancer Screening Research Colorectal Cancer Screening (PDQ®)–Patient Version What is screening? Go ... These are called diagnostic tests . General Information About Colorectal Cancer Key Points Colorectal cancer is a disease in ...

  5. Screening_mgmt: a Python module for managing screening data.

    Science.gov (United States)

    Helfenstein, Andreas; Tammela, Päivi

    2015-02-01

    High-throughput screening is an established technique in drug discovery and, as such, has also found its way into academia. High-throughput screening generates a considerable amount of data, which is why specific software is used for its analysis and management. The commercially available software packages are often beyond the financial limits of small-scale academic laboratories and, furthermore, lack the flexibility to fulfill certain user-specific requirements. We have developed a Python module, screening_mgmt, which is a lightweight tool for flexible data retrieval, analysis, and storage for different screening assays in one central database. The module reads custom-made analysis scripts and plotting instructions, and it offers a graphical user interface to import, modify, and display the data in a uniform manner. During the test phase, we used this module for the management of 10,000 data points of various origins. It has provided a practical, user-friendly tool for sharing and exchanging information between researchers. © 2014 Society for Laboratory Automation and Screening.

  6. Single-Lap-Joint Screening of Hysol EA 9309NA Epoxy Adhesive

    Science.gov (United States)

    2017-05-01

    Acknowledgments This research was supported in part by the US Army Education Outreach Programs (Science and Engineering Apprentice Program and College...useful for estimating downstream logistical phase- out risk based on current and pending environmental regulations . Second-tier testing consists of...was used to ensure that the breaking load of single-lap-joint samples fell between 15% and 85% of the cell’s full-scale capacity. A crosshead speed

  7. Bavarian mammography screening program; Bayerisches Mammographiescreening (BMS)

    Energy Technology Data Exchange (ETDEWEB)

    Willgeroth, F. [Lenkungsausschuss BMS (Germany); Universitaetsfrauenklinik Innenstadt, Muenchen (Germany); Baumann, M.; Blaser, D.; Froschauer, S.; Kaeaeb, V.; Stich, V.; Thomaschewski, S.; Walter, D. [Kassenaerztliche Vereinigung Bayern (Germany); Crispin, A. [Klinikum Grosshadern der LMU Muenchen, Institut fuer Medizinische Informationsverarbeitung (Germany); Waal, J. de; Heywang-Koebrunner, S.; Rothe, R. [Lenkungsausschuss BMS (Germany); Hoelzel, D. [Lenkungsausschuss BMS (Germany); Klinikum Grosshadern der LMU Muenchen, Institut fuer Medizinische Informationsverarbeitung (Germany)

    2005-03-01

    In Bavaria since the 1st April 2003 we have been conducting a high quality mammography-screening carried out in individual practises (BMS). We have used the European and the S 3 guidelines. The best diagnosis is an early diagnosis of the breast carcinoma to save human life. Because of this and the high mortality rate due to this disease it is essential to have a mammogram screening program. There is no single one ideal way of constructing a screening program, it is always based on compromise within the particular health care-systems. Arising problems cannot be avoided, it is only possible when all parties work closely together that the BMS works properly. (orig.) [German] In Bayern laeuft seit dem 01.04.2003 ein qualitaetsgesichertes, flaechendeckendes Mammographiescreening mit dezentralem Charakter (BMS). Zugrunde liegen die Empfehlungen der European Guidelines sowie der S-3-Leitlinie. Die Vorverlegung der Diagnostik ist beim Mammakarzinom bis heute die effektivste Moeglichkeit, um das Leben von Frauen zu retten, die an diesem Krebs erkrankt sind. Daraus und aufgrund der hohen Mortalitaetsrate dieser Erkrankung leitet sich die Notwendigkeit eines Screeningprogramms ab. Dessen Aufbau kann unterschiedlich sein, denbesten Weg gibt es nicht; es wird sich immer eine Kompromissloesung ergeben, die sehr stark vom jeweiligen Gesundheitssystem beeinflusst wird. Auftretende Probleme sind vielschichtig. Nur durch gemeinsame Anstrengungen aller Beteiligten liess sich das Bayerische Mammographiescreening installieren. (orig.)

  8. Effects of Screening for Psychological Distress on Patient Outcomes in Cancer: a Systematic Review

    Science.gov (United States)

    Meijer, Anna; Roseman, Michelle; Delisle, Vanessa C.; Milette, Katherine; Levis, Brooke; Syamchandra, Achyuth; Stefanek, Michael E.; Stewart, Donna E.; de Jonge, Peter; Coyne, James C.; Thombs, Brett D.

    2013-01-01

    Objective Several practice guidelines recommend routine screening for psychological distress in cancer care. The objective was to evaluate the effect of screening cancer patients for psychological distress by assessing the (1) effectiveness of interventions to reduce distress among patients identified as distressed; and (2) effects of screening for distress on distress outcomes. Methods CINAHL, Cochrane, EMBASE, ISI, MEDLINE, PsycINFO, and SCOPUS databases were searched through April 6, 2011 with manual searches of 45 relevant journals, reference list review, citation tracking of included articles, and trial registry reviews through June 30, 2012. Articles in any language on cancer patients were included if they (1) compared treatment for patients with psychological distress to placebo or usual care in a randomized controlled trial (RCT); or (2) assessed the effect of screening on psychological distress in a RCT. Results There were 14 eligible RCTs for treatment of distress, and 1 RCT on the effects of screening on patient distress. Pharmacological, psychotherapy and collaborative care interventions generally reduced distress with small to moderate effects. One study investigated effects of screening for distress on psychological outcomes, and it found no improvement. Conclusion Treatment studies reported modest improvement in distress symptoms, but only a single eligible study was found on the effects of screening cancer patients for distress, and distress did not improve in screened patients versus those receiving usual care. Because of the lack of evidence of beneficial effects of screening cancer patients for distress, it is premature to recommend or mandate implementation of routine screening. PMID:23751231

  9. Screen-film mammography

    International Nuclear Information System (INIS)

    Logan, W.W.; Janus, J.A.

    1987-01-01

    The development of screen-film mammography has resulted in the re-emergence of confidence, rather than fear, in mammography. When screen-film mammography is performed with state-of-the-art dedicated equipment utilizing vigorous breast compression and a ''soft'' x-ray beam for improved contrast, screen-film images are equivalent or superior to those of reduced-dose xeromammography and superior to those of nonscreen film mammography. Technological aids for conversion from xeromammographic or nonscreen film mammographic techniques to screen-film techniques have been described. Screen-film mammography should not be attempted until dedicated equipment has been obtained and the importance of vigorous compression has been understood

  10. Impact of non-clinical community-based promotional campaigns on bowel cancer screening engagement: An integrative literature review.

    Science.gov (United States)

    Martini, Angelita; Morris, Julia N; Preen, David

    2016-10-01

    This paper reviewed the relationship between non-clinical, client-oriented promotional campaigns to raise bowel cancer awareness and screening engagement. An integrative literature review using predefined search terms was conducted to summarise the accumulated knowledge. Data was analysed by coding and categorising, then synthesized through development of themes. Eighteen of 116 studies met inclusion criteria. Promotional campaigns had varying impact on screening uptake for bowel cancer. Mass media was found to moderately increase screening, predominately amongst "worried well". Small media used in conjunction with other promotional activities, thus its effect on screening behaviours was unclear. One-on-one education was less effective and less feasible than group education in increasing intention to screen. Financial support was ineffective in increasing screening rates when compared to other promotional activities. Screening engagement increased because of special events and celebrity endorsement. Non-clinical promotional campaigns did impact uptake of bowel cancer screening engagement. However, little is evident on the effect of single types of promotion and most research is based on clinician-directed campaigns. Cancer awareness and screening promotions should be implemented at community and clinical level to maximize effectiveness. Such an approach will ensure promotional activities are targeting consumers, thus strengthening screening engagement. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. Family structure as a predictor of screen time among youth.

    Science.gov (United States)

    McMillan, Rachel; McIsaac, Michael; Janssen, Ian

    2015-01-01

    The family plays a central role in the development of health-related behaviors among youth. The objective of this study was to determine whether non-traditional parental structure and shared custody arrangements predict how much time youth spend watching television, using a computer recreationally, and playing video games. Participants were a nationally representative sample of Canadian youth (N = 26,068) in grades 6-10 who participated in the 2009/10 Health Behaviour in School-aged Children Survey. Screen time in youth from single parent and reconstituted families, with or without regular visitation with their non-residential parent, was compared to that of youth from traditional dual-parent families. Multiple imputation was used to account for missing data. After multiple imputation, the relative odds of being in the highest television, computer use, video game, and total screen time quartiles were not different in boys and girls from non-traditional families by comparison to boys and girls from traditional dual-parent families. In conclusion, parental structure and child custody arrangements did not have a meaningful impact on screen time among youth.

  12. Family structure as a predictor of screen time among youth

    Directory of Open Access Journals (Sweden)

    Rachel McMillan

    2015-06-01

    Full Text Available The family plays a central role in the development of health-related behaviors among youth. The objective of this study was to determine whether non-traditional parental structure and shared custody arrangements predict how much time youth spend watching television, using a computer recreationally, and playing video games. Participants were a nationally representative sample of Canadian youth (N = 26,068 in grades 6–10 who participated in the 2009/10 Health Behaviour in School-aged Children Survey. Screen time in youth from single parent and reconstituted families, with or without regular visitation with their non-residential parent, was compared to that of youth from traditional dual-parent families. Multiple imputation was used to account for missing data. After multiple imputation, the relative odds of being in the highest television, computer use, video game, and total screen time quartiles were not different in boys and girls from non-traditional families by comparison to boys and girls from traditional dual-parent families. In conclusion, parental structure and child custody arrangements did not have a meaningful impact on screen time among youth.

  13. Local electric field screening in bi-layer graphene devices

    Directory of Open Access Journals (Sweden)

    Vishal ePanchal

    2014-02-01

    Full Text Available We present experimental studies of both local and macroscopic electrical effects in uniform single- (1LG and bi-layer graphene (2LG devices as well as in devices with non-uniform graphene coverage, under ambient conditions. DC transport measurements on sub-micron scale Hall bar devices were used to show a linear rise in carrier density with increasing amounts of 2LG coverage. Electrical scanning gate microscopy was used to locally top gate uniform and non-uniform devices in order to observe the effect of local electrical gating. We experimentally show a significant level of electric field screening by 2LG. We demonstrate that SGM technique is an extremely useful research tool for studies of local screening effects, which provides a complementary view on phenomena that are usually considered only within a macroscopic experimental scheme.

  14. Engineering aspects of Passavant screening

    International Nuclear Information System (INIS)

    Siddle, K.R.; Sharma, R.K.

    1978-01-01

    The Passavant screen was developed in Europe almost 30 years ago. The Passavant screen is a vertical traveling screen; however, the basic difference between the conventional vertical traveling screen and the Passavant screen is that in the conventional screen water passes through the front screen belt and then the back screen belt, whereas in the Passavant screen the water enters in between the two belts and passes laterally through either of the belts. Thus, theoretically, the screening surface of the Passavant screen is doubled as compared to the same size conventional vertical traveling screen. Various design and operational modifications of the Passavant screen are possible to yield optimum design and performance characteristics which make it amenable to installation at power plants for safe removal of not only fish but also smaller organisms such as fish eggs and larvae. In this paper, details of the screen design and operational characteristics are discussed with notes on how these features can be modified to suit site- and organism-specific requirements

  15. Screening strategies for atrial fibrillation: a systematic review and cost-effectiveness analysis.

    Science.gov (United States)

    Welton, Nicky J; McAleenan, Alexandra; Thom, Howard Hz; Davies, Philippa; Hollingworth, Will; Higgins, Julian Pt; Okoli, George; Sterne, Jonathan Ac; Feder, Gene; Eaton, Diane; Hingorani, Aroon; Fawsitt, Christopher; Lobban, Trudie; Bryden, Peter; Richards, Alison; Sofat, Reecha

    2017-05-01

    -effective than systematic population screening, as long as the uptake of opportunistic screening observed in randomised controlled trials translates to practice. Modified blood pressure monitors, photoplethysmography or nurse pulse palpation were more likely to be cost-effective than other screening tests. A screening strategy with an initial screening age of 65 years and repeated screens every 5 years until age 80 years was likely to be cost-effective, provided that compliance with treatment does not decline with increasing age. A national screening programme for AF is likely to represent a cost-effective use of resources. Systematic opportunistic screening is more likely to be cost-effective than systematic population screening. Nurse pulse palpation or modified blood pressure monitors would be appropriate screening tests, with confirmation by diagnostic 12-lead electrocardiography interpreted by a trained GP, with referral to a specialist in the case of an unclear diagnosis. Implementation strategies to operationalise uptake of systematic opportunistic screening in primary care should accompany any screening recommendations. Many inputs for the economic model relied on a single trial [the Screening for Atrial Fibrillation in the Elderly (SAFE) study] and DTA results were based on a few studies at high risk of bias/of low applicability. Comparative studies measuring long-term outcomes of screening strategies and DTA studies for new, emerging technologies and to replicate the results for photoplethysmography and GP interpretation of 12-lead electrocardiography in a screening population. This study is registered as PROSPERO CRD42014013739. The National Institute for Health Research Health Technology Assessment programme.

  16. Toxicology screen

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003578.htm Toxicology screen To use the sharing features on this page, please enable JavaScript. A toxicology screen refers to various tests that determine the ...

  17. Mental Health Screening Center

    Science.gov (United States)

    ... Releases & Announcements Public Service Announcements Partnering with DBSA Mental Health Screening Center These online screening tools are not ... you have any concerns, see your doctor or mental health professional. Depression Screening for Adult Depression Screening for ...

  18. Pooled-matrix protein interaction screens using Barcode Fusion Genetics.

    Science.gov (United States)

    Yachie, Nozomu; Petsalaki, Evangelia; Mellor, Joseph C; Weile, Jochen; Jacob, Yves; Verby, Marta; Ozturk, Sedide B; Li, Siyang; Cote, Atina G; Mosca, Roberto; Knapp, Jennifer J; Ko, Minjeong; Yu, Analyn; Gebbia, Marinella; Sahni, Nidhi; Yi, Song; Tyagi, Tanya; Sheykhkarimli, Dayag; Roth, Jonathan F; Wong, Cassandra; Musa, Louai; Snider, Jamie; Liu, Yi-Chun; Yu, Haiyuan; Braun, Pascal; Stagljar, Igor; Hao, Tong; Calderwood, Michael A; Pelletier, Laurence; Aloy, Patrick; Hill, David E; Vidal, Marc; Roth, Frederick P

    2016-04-22

    High-throughput binary protein interaction mapping is continuing to extend our understanding of cellular function and disease mechanisms. However, we remain one or two orders of magnitude away from a complete interaction map for humans and other major model organisms. Completion will require screening at substantially larger scales with many complementary assays, requiring further efficiency gains in proteome-scale interaction mapping. Here, we report Barcode Fusion Genetics-Yeast Two-Hybrid (BFG-Y2H), by which a full matrix of protein pairs can be screened in a single multiplexed strain pool. BFG-Y2H uses Cre recombination to fuse DNA barcodes from distinct plasmids, generating chimeric protein-pair barcodes that can be quantified via next-generation sequencing. We applied BFG-Y2H to four different matrices ranging in scale from ~25 K to 2.5 M protein pairs. The results show that BFG-Y2H increases the efficiency of protein matrix screening, with quality that is on par with state-of-the-art Y2H methods. © 2016 The Authors. Published under the terms of the CC BY 4.0 license.

  19. Screening history in women with cervical cancer in a Danish population-based screening program

    DEFF Research Database (Denmark)

    Kirschner, Benny; Poll, Susanne; Rygaard, Carsten

    2011-01-01

    The aim of this study was to explore the screening histories of all cervical cancers in a Danish screening population. The intention was to decide suboptimal sides of the screening program and to evaluate the significance of routine screening in the development of cervical cancer.......The aim of this study was to explore the screening histories of all cervical cancers in a Danish screening population. The intention was to decide suboptimal sides of the screening program and to evaluate the significance of routine screening in the development of cervical cancer....

  20. Compatibility of automatic exposure control with new screen phosphors in diagnostic roentgenography

    International Nuclear Information System (INIS)

    Mulvaney, J.A.

    1982-01-01

    Automatic exposure control systems are used in diagnostic roentgenography to obtain proper film density for a variety of patient examinations and roentgenographic techniques. Most automatic exposure control systems have been designed for use with par speed, calcium tungstate intensifying screens. The use of screens with faster speeds and new phosphor materials has put extreme demands on present systems. The performance of a representative automatic exposure control system is investigated to determine its ability to maintain constant film density over a wide range of x-ray tube voltages and acrylic phantom thicknesses with four different intensifying screen phosphors. The effects of x-ray energy dependence, generator switching time and stored change are investigated. The system is able to maintain film density to within plus or minus 0.2 optical density units for techniques representing adult patients. A single nonadjustable tube voltage compensation circuit is adequate for the four different screen phosphors for x-ray tube voltages above sixty peak kilovolts. For techniques representing pediatric patients at high x-ray tube voltages, excess film density occurs due to stored charge in the transformer and high-voltage cables. An anticipation circuit in the automatic exposure control circuit can be modified to correct for stored charge effects. In a seperate experiment the energy dependence of three different ionization chamber detectors used in automatic exposure control systems is compared directly with the energy dependence of three different screen phosphors. The data on detector sensitivity and screen speed are combined to predict the best tube voltage compensation for each combination of screen and detector

  1. High-throughput screening of filamentous fungi using nanoliter-range droplet-based microfluidics

    Science.gov (United States)

    Beneyton, Thomas; Wijaya, I. Putu Mahendra; Postros, Prexilia; Najah, Majdi; Leblond, Pascal; Couvent, Angélique; Mayot, Estelle; Griffiths, Andrew D.; Drevelle, Antoine

    2016-06-01

    Filamentous fungi are an extremely important source of industrial enzymes because of their capacity to secrete large quantities of proteins. Currently, functional screening of fungi is associated with low throughput and high costs, which severely limits the discovery of novel enzymatic activities and better production strains. Here, we describe a nanoliter-range droplet-based microfluidic system specially adapted for the high-throughput sceening (HTS) of large filamentous fungi libraries for secreted enzyme activities. The platform allowed (i) compartmentalization of single spores in ~10 nl droplets, (ii) germination and mycelium growth and (iii) high-throughput sorting of fungi based on enzymatic activity. A 104 clone UV-mutated library of Aspergillus niger was screened based on α-amylase activity in just 90 minutes. Active clones were enriched 196-fold after a single round of microfluidic HTS. The platform is a powerful tool for the development of new production strains with low cost, space and time footprint and should bring enormous benefit for improving the viability of biotechnological processes.

  2. ScreenOS Cookbook

    CERN Document Server

    Brunner, Stefan; Delcourt, David

    2008-01-01

    In the only book that completely covers ScreenOS, six key members of Juniper Network's ScreenOS development team help you troubleshoot secure networks using ScreenOS firewall appliances. Over 200 recipes address a wide range of security issues, provide step-by-step solutions, and include discussions of why the recipes work, so you can easily set up and keep ScreenOS systems on track. The easy-to-follow format enables you to find the topic and specific recipe you need right away.

  3. P-02: Echocardiography Has Low Clinical Efficacy of Libyan Screening Protocol in Athletes

    Directory of Open Access Journals (Sweden)

    Salaheddin Sharif

    2017-03-01

    Full Text Available INTRODUCTIONPre-participation screening has been largely accepted as a means to identify those athletes at risk of cardiovascular diseases which are responsible for sudden cardiac death. The objectives of athlete screening are to reduce injuries and prevent sudden. However, there is no single commonly adopted protocol to screen athletes. Although the European Society of Cardiology and the American Heart Association recommend the routine screening of athletes to prevent sudden death, there is significant disagreement regarding use 12 lead ECG. FIFA has recommend the inclusion of an Echocardiography (ECHO in screening protocol.PURPOSEExplore the debate regarding differences between European and the USA pre-participation screening protocol for sudden death while also considering pre-competition medical assessment protocol used by the Libyan Football Federation. To provide evidence based recommendations on the best protocol to be used for pre-participation screening, and thus to standardize the screening method.MATERIALS and METHOD1236 male athletic received a medical history, general physical examination, cardiovascular and musculoskeletal examination, 12 lead ECG, blood laboratory test, and echocardiography.FINDINGS1235 athletics were found to be eligible to participate in sport and were given a full medical clearance. One athletic was diagnosed with second degree heart block by ECG while his medical history, physical examination, echocardiograph, and blood test were normal.DISCUSSIONEchocardiography alone do did not identify pathological condition and using echocardiography is still controversial and clinically not effective in young athletesCONCLUSIONThe Screening protocol should include a combination of medical history, physical examination and ECG due to the high sensitivity found, and thus it was able to identify all athletes at risk for the disease.

  4. An investigation into why two-view mammography is better than one-view in breast cancer screening

    International Nuclear Information System (INIS)

    Hackshaw, A.K.; Wald, N.J.; Michell, M.J.; Field, S.; Wilson, A.R.M.

    2000-01-01

    AIM: To determine why two-view mammography in screening for breast cancer is more effective than using a single medio-lateral oblique view. MATERIALS AND METHODS: In the United Kingdom Coordinating Committee on Cancer Research randomized trial of one- vs two-view mammography in breast cancer screening the oblique view was assessed by one radiologist and two views (oblique and cranio-caudal) assessed by another. For the present study the mammographic films were retrieved from the screening centres and assessed by three consultant radiologists. Mammographic films were available from 110 women; 87 had their breast cancer detected by both one and two views and in 23 it was missed by one view but detected using two views. Outcome measures were breast size, location and size of the cancer, mammographic features, presence of microcalcification and overall radiological assessment. RESULTS: Although 23 cancers were missed in the original trial when one view was used, only two were not visible on the oblique view. Cancers missed using a single oblique view (and only detected if the cranio-caudal view was available with the oblique) tended to be smaller by about 4 mm (P = 0.05), centrally located in the breast (P = 0.16), not spiculated or round, (P ≤ 0.001) and lacked microcalcification (P = 0.15). Breast size and breast radiographic density were not significantly associated with breast cancer detection. CONCLUSIONS: The results provide the basis for the observation that two-view mammographic screening is more effective than one-view mammographic screening. Hackshaw, A. (2000). Clinical Radiology 55, 454-458

  5. An electronic screen for triaging adolescent substance use by risk levels.

    Science.gov (United States)

    Levy, Sharon; Weiss, Roger; Sherritt, Lon; Ziemnik, Rosemary; Spalding, Allegra; Van Hook, Shari; Shrier, Lydia A

    2014-09-01

    differences were found in sensitivity or specificity between the full tool and the Screening to Brief Intervention. A single screening question assessing past-year frequency use for 8 commonly misused categories of substances appears to be a valid method for discriminating among clinically relevant risk categories of adolescent substance use.

  6. Role of optometry school in single day large scale school vision testing

    Science.gov (United States)

    Anuradha, N; Ramani, Krishnakumar

    2015-01-01

    Background: School vision testing aims at identification and management of refractive errors. Large-scale school vision testing using conventional methods is time-consuming and demands a lot of chair time from the eye care professionals. A new strategy involving a school of optometry in single day large scale school vision testing is discussed. Aim: The aim was to describe a new approach of performing vision testing of school children on a large scale in a single day. Materials and Methods: A single day vision testing strategy was implemented wherein 123 members (20 teams comprising optometry students and headed by optometrists) conducted vision testing for children in 51 schools. School vision testing included basic vision screening, refraction, frame measurements, frame choice and referrals for other ocular problems. Results: A total of 12448 children were screened, among whom 420 (3.37%) were identified to have refractive errors. 28 (1.26%) children belonged to the primary, 163 to middle (9.80%), 129 (4.67%) to secondary and 100 (1.73%) to the higher secondary levels of education respectively. 265 (2.12%) children were referred for further evaluation. Conclusion: Single day large scale school vision testing can be adopted by schools of optometry to reach a higher number of children within a short span. PMID:25709271

  7. Development and applicability of a ready-to-use PCR system for GMO screening.

    Science.gov (United States)

    Rosa, Sabrina F; Gatto, Francesco; Angers-Loustau, Alexandre; Petrillo, Mauro; Kreysa, Joachim; Querci, Maddalena

    2016-06-15

    With the growing number of GMOs introduced to the market, testing laboratories have seen their workload increase significantly. Ready-to-use multi-target PCR-based detection systems, such as pre-spotted plates (PSP), reduce analysis time while increasing capacity. This paper describes the development and applicability to GMO testing of a screening strategy involving a PSP and its associated web-based Decision Support System. The screening PSP was developed to detect all GMOs authorized in the EU in one single PCR experiment, through the combination of 16 validated assays. The screening strategy was successfully challenged in a wide inter-laboratory study on real-life food/feed samples. The positive outcome of this study could result in the adoption of a PSP screening strategy across the EU; a step that would increase harmonization and quality of GMO testing in the EU. Furthermore, this system could represent a model for other official control areas where high-throughput DNA-based detection systems are needed. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  8. Screen printing as a scalable and low-cost approach for rigid and flexible thin-film transistors using separated carbon nanotubes.

    Science.gov (United States)

    Cao, Xuan; Chen, Haitian; Gu, Xiaofei; Liu, Bilu; Wang, Wenli; Cao, Yu; Wu, Fanqi; Zhou, Chongwu

    2014-12-23

    Semiconducting single-wall carbon nanotubes are very promising materials in printed electronics due to their excellent mechanical and electrical property, outstanding printability, and great potential for flexible electronics. Nonetheless, developing scalable and low-cost approaches for manufacturing fully printed high-performance single-wall carbon nanotube thin-film transistors remains a major challenge. Here we report that screen printing, which is a simple, scalable, and cost-effective technique, can be used to produce both rigid and flexible thin-film transistors using separated single-wall carbon nanotubes. Our fully printed top-gated nanotube thin-film transistors on rigid and flexible substrates exhibit decent performance, with mobility up to 7.67 cm2 V(-1) s(-1), on/off ratio of 10(4)∼10(5), minimal hysteresis, and low operation voltage (transistors (bent with radius of curvature down to 3 mm) and driving capability for organic light-emitting diode have been demonstrated. Given the high performance of the fully screen-printed single-wall carbon nanotube thin-film transistors, we believe screen printing stands as a low-cost, scalable, and reliable approach to manufacture high-performance nanotube thin-film transistors for application in display electronics. Moreover, this technique may be used to fabricate thin-film transistors based on other materials for large-area flexible macroelectronics, and low-cost display electronics.

  9. Waste Tank Safety Screening Module: An aspect of Hanford Site tank waste characterization

    International Nuclear Information System (INIS)

    Hill, J.G.; Wood, T.W.; Babad, H.; Redus, K.S.

    1994-01-01

    Forty-five (45) of the 149 Hanford single-shell tanks have been designated as Watch-List tanks for one or more high-priority safety issues, which include significant concentrations of organic materials, ferrocyanide salts, potential generation of flammable gases, high heat generation, criticality, and noxious vapor generation. While limited waste characterization data have been acquired on these wastes under the original Tri-Party Agreement, to date all of the tank-by-tank assessments involved in these safety issue designations have been based on historical data rather than waste on data. In response to guidance from the Defense Nuclear Facilities Safety Board (DNFSB finding 93-05) and related direction from the US Department of Energy (DOE), Westinghouse Hanford Company, assisted by Pacific Northwest Laboratory, designed a measurements-based screening program to screen all single-shell tanks for all of these issues. This program, designated the Tank Safety Screening Module (TSSM), consists of a regime of core, supernatant, and auger samples and associated analytical measurements intended to make first-order discriminations of the safety status on a tank-by-tank basis. The TSSM combines limited tank sampling and analysis with monitoring and tank history to provide an enhanced measurement-based categorization of the tanks relative to the safety issues. This program will be implemented beginning in fiscal year (FY) 1994 and supplemented by more detailed characterization studies designed to support safety issue resolution

  10. Genomic screening for dissection of a complex disease: The multiple sclerosis phenotype

    Energy Technology Data Exchange (ETDEWEB)

    Haines, J.L.; Bazyk, A.; Gusella, J.F. [Massachusetts General Hospital, Boston, MA (United States)] [and others

    1994-09-01

    Application of positional cloning to diseases with a complex etiology is fraught with problems. These include undefined modes of inheritance, heterogeneity, and epistasis. Although microsatellite markers now make genotyping the genome a straightforward task, no single analytical method is available to efficiently and accurately use these data for a complex disease. We have developed a multi-stage genomic screening strategy which uses a combination of non-parametric approaches (Affected Pedigree Member (APM) linkage analysis and robust sib pair analysis (SP)), and the parametric lod score approach (using four different genetic models). To warrant follow-up, a marker must have two or more of: a nominal P value of 0.05 or less on the non-parametric tests, or a lod score greater than 1.0 for any model. Two adjacent markers each fulfilling one criterion are also considered for follow-up. These criteria were determined both by simulation studies and our empirical experience in screening a large number of other disorders. We applied this approach to multiple sclerosis (MS), a complex neurological disorder with a strong but ill-defined genetic component. Analysis of the first 91 markers from our screen of 55 multiplex families found 5 markers which met the SP criteria, 13 markers which met the APM criteria, and 8 markers which met the lod score criteria. Five regions (on chromosomes 2, 4, 7, 14, and 19) met our overall criteria. However, no single method identified all of these regions, suggesting that each method is sensitive to various (unknown) influences. The chromosome 14 results were not supported by follow-up typing and analysis of markers in that region, but the chromosome 19 results remain well supported. Updated screening results will be presented.

  11. Screening hybridomas for anabolic androgenic steroids by steroid analog antigen microarray.

    Science.gov (United States)

    Du, Hongwu; Chen, Guangyu; Bian, Yongzhong; Xing, Cenzan; Ding, Xue; Zhu, Mengliang; Xun, Yiping; Chen, Peng; Zhou, Yabin; Li, Shaoxu

    2015-01-01

    Currently, dozens of anabolic androgenic steroids (AAS) are forbidden in the World Anti-Doping Agency Prohibited List, however, despite extensive investigation, there are still lots of AAS without corresponding monoclonal antibodies. A steroid analog antigen microarray made up of ten AAS was fabricated to screen the hybridoma and it was found an original unsuccessful clone turned out to be a candidate anti-boldenone antibody, without any cross-reactions with endogenous AAS or 44 different AAS standard reference materials tested. Our findings suggested that steroid analog antigen microarray could be a promising tool to screen and characterize new applications of antibodies for structure analogs, and this also exhibits the potential to fast identify effective epitopes of hybridomas in a single assay.

  12. Metabolite profiling of microfluidic cell culture conditions for droplet based screening

    DEFF Research Database (Denmark)

    Björk, Sara M.; Sjoström, Staffan L.; Svahn, Helene Andersson

    2015-01-01

    We investigate the impact of droplet culture conditions on cell metabolic state by determining key metabolite concentrations in S. cerevisiae cultures in different microfluidic droplet culture formats. Control of culture conditions is critical for single cell/clone screening in droplets......, such as directed evolution of yeast, as cell metabolic state directly affects production yields from cell factories. Here, we analyze glucose, pyruvate, ethanol, and glycerol, central metabolites in yeast glucose dissimilation to establish culture formats for screening of respiring as well as fermenting yeast...... limited cultures, whereas the metabolite profiles of cells cultured in the alternative wide tube droplet incubation format resemble those from aerobic culture. Furthermore, we demonstrate retained droplet stability and size in the new better oxygenated droplet incubation format....

  13. Preimplantation genetic screening.

    Science.gov (United States)

    Harper, Joyce C

    2018-03-01

    Preimplantation genetic diagnosis was first successfully performed in 1989 as an alternative to prenatal diagnosis for couples at risk of transmitting a genetic or chromosomal abnormality, such as cystic fibrosis, to their child. From embryos generated in vitro, biopsied cells are genetically tested. From the mid-1990s, this technology has been employed as an embryo selection tool for patients undergoing in vitro fertilisation, screening as many chromosomes as possible, in the hope that selecting chromosomally normal embryos will lead to higher implantation and decreased miscarriage rates. This procedure, preimplantation genetic screening, was initially performed using fluorescent in situ hybridisation, but 11 randomised controlled trials of screening using this technique showed no improvement in in vitro fertilisation delivery rates. Progress in genetic testing has led to the introduction of array comparative genomic hybridisation, quantitative polymerase chain reaction, and next generation sequencing for preimplantation genetic screening, and three small randomised controlled trials of preimplantation genetic screening using these new techniques indicate a modest benefit. Other trials are still in progress but, regardless of their results, preimplantation genetic screening is now being offered globally. In the near future, it is likely that sequencing will be used to screen the full genetic code of the embryo.

  14. Toward a generalized and high-throughput enzyme screening system based on artificial genetic circuits.

    Science.gov (United States)

    Choi, Su-Lim; Rha, Eugene; Lee, Sang Jun; Kim, Haseong; Kwon, Kilkoang; Jeong, Young-Su; Rhee, Young Ha; Song, Jae Jun; Kim, Hak-Sung; Lee, Seung-Goo

    2014-03-21

    Large-scale screening of enzyme libraries is essential for the development of cost-effective biological processes, which will be indispensable for the production of sustainable biobased chemicals. Here, we introduce a genetic circuit termed the Genetic Enzyme Screening System that is highly useful for high-throughput enzyme screening from diverse microbial metagenomes. The circuit consists of two AND logics. The first AND logic, the two inputs of which are the target enzyme and its substrate, is responsible for the accumulation of a phenol compound in cell. Then, the phenol compound and its inducible transcription factor, whose activation turns on the expression of a reporter gene, interact in the other logic gate. We confirmed that an individual cell harboring this genetic circuit can present approximately a 100-fold higher cellular fluorescence than the negative control and can be easily quantified by flow cytometry depending on the amounts of phenolic derivatives. The high sensitivity of the genetic circuit enables the rapid discovery of novel enzymes from metagenomic libraries, even for genes that show marginal activities in a host system. The crucial feature of this approach is that this single system can be used to screen a variety of enzymes that produce a phenol compound from respective synthetic phenyl-substrates, including cellulase, lipase, alkaline phosphatase, tyrosine phenol-lyase, and methyl parathion hydrolase. Consequently, the highly sensitive and quantitative nature of this genetic circuit along with flow cytometry techniques could provide a widely applicable toolkit for discovering and engineering novel enzymes at a single cell level.

  15. Hematuria screening test for urinary bladder mucosal infiltration in cervical cancer.

    Science.gov (United States)

    Chuttiangtum, Ayuth; Udomthavornsuk, Banchong; Chumworathayi, Bandit

    2012-01-01

    To determine the diagnostic performance of hematuria as a screening test for urinary bladder infiltration in cervical cancer patients with a prospective study design. Newly diagnosed cervical cancer patients at Srinagarind hospital from 14 June 2011 to 30 April 2012 were enrolled in this study. We collected midstream urine samples for urinalysis from every patient before routine cystoscopic exam for clinical staging. The presence of 3 or more red blood cells (RBCs) per high power field was defined as positive for hematuria. A two-by-two table was used to determine the diagnostic performance of hematuria to detect urinary bladder mucosal infiltration using cystoscopy and biopsy as the gold standard. A total of 130 were patients included, 54 of which (41.5%) had hematuria. Of these, four patients (3.08%) had pathological report from cystoscopic biopsy confirmed metastatic squamous cell carcinoma. The sensitivity, specificity, PPV, NPV, and accuracy of hematuria as a screening test to detect urinary bladder mucosal infiltration of cervical cancer were 100%, 60.3%, 7.4%, 100%, and 61.5%, respectively. There was no single case of urinary bladder mucosal infiltration in patients initially staged less than stage III. Hematuria can be used as a screening test to detect urinary bladder mucosal infiltration of cervical cancer. This can reduce the number of cervical cancer patients who really need to undergo cystoscopy as a staging procedure to less than half and to less than 20% if stage III or more were included without missing a single case of urinary bladder mucosal infiltration.

  16. Computed tomographic characteristics of interval and post screen carcinomas in lung cancer screening

    International Nuclear Information System (INIS)

    Scholten, Ernst T.; Horeweg, Nanda; Koning, Harry J. de; Vliegenthart, Rozemarijn; Oudkerk, Matthijs; Mali, Willem P.T.M.; Jong, Pim A. de

    2015-01-01

    To analyse computed tomography (CT) findings of interval and post-screen carcinomas in lung cancer screening. Consecutive interval and post-screen carcinomas from the Dutch-Belgium lung cancer screening trial were included. The prior screening and the diagnostic chest CT were reviewed by two experienced radiologists in consensus with knowledge of the tumour location on the diagnostic CT. Sixty-one participants (53 men) were diagnosed with an interval or post-screen carcinoma. Twenty-two (36 %) were in retrospect visible on the prior screening CT. Detection error occurred in 20 cancers and interpretation error in two cancers. Errors involved intrabronchial tumour (n = 5), bulla with wall thickening (n = 5), lymphadenopathy (n = 3), pleural effusion (n = 1) and intraparenchymal solid nodules (n = 8). These were missed because of a broad pleural attachment (n = 4), extensive reticulation surrounding a nodule (n = 1) and extensive scarring (n = 1). No definite explanation other than human error was found in two cases. None of the interval or post-screen carcinomas involved a subsolid nodule. Interval or post-screen carcinomas that were visible in retrospect were mostly due to detection errors of solid nodules, bulla wall thickening or endobronchial lesions. Interval or post-screen carcinomas without explanation other than human errors are rare. (orig.)

  17. Computed tomographic characteristics of interval and post screen carcinomas in lung cancer screening

    Energy Technology Data Exchange (ETDEWEB)

    Scholten, Ernst T. [University Medical Centre, Department of Radiology, Utrecht (Netherlands); Kennemer Gasthuis, Department of Radiology, Haarlem (Netherlands); Horeweg, Nanda [Erasmus University Medical Centre, Department of Public Health, Rotterdam (Netherlands); Erasmus University Medical Centre, Department of Pulmonary Medicine, Rotterdam (Netherlands); Koning, Harry J. de [Erasmus University Medical Centre, Department of Public Health, Rotterdam (Netherlands); Vliegenthart, Rozemarijn [University of Groningen, University Medical Centre Groningen, Department of Radiology, Groningen (Netherlands); University of Groningen, University Medical Centre Groningen, Center for Medical Imaging-North East Netherlands, Groningen (Netherlands); Oudkerk, Matthijs [University of Groningen, University Medical Centre Groningen, Center for Medical Imaging-North East Netherlands, Groningen (Netherlands); Mali, Willem P.T.M.; Jong, Pim A. de [University Medical Centre, Department of Radiology, Utrecht (Netherlands)

    2015-01-15

    To analyse computed tomography (CT) findings of interval and post-screen carcinomas in lung cancer screening. Consecutive interval and post-screen carcinomas from the Dutch-Belgium lung cancer screening trial were included. The prior screening and the diagnostic chest CT were reviewed by two experienced radiologists in consensus with knowledge of the tumour location on the diagnostic CT. Sixty-one participants (53 men) were diagnosed with an interval or post-screen carcinoma. Twenty-two (36 %) were in retrospect visible on the prior screening CT. Detection error occurred in 20 cancers and interpretation error in two cancers. Errors involved intrabronchial tumour (n = 5), bulla with wall thickening (n = 5), lymphadenopathy (n = 3), pleural effusion (n = 1) and intraparenchymal solid nodules (n = 8). These were missed because of a broad pleural attachment (n = 4), extensive reticulation surrounding a nodule (n = 1) and extensive scarring (n = 1). No definite explanation other than human error was found in two cases. None of the interval or post-screen carcinomas involved a subsolid nodule. Interval or post-screen carcinomas that were visible in retrospect were mostly due to detection errors of solid nodules, bulla wall thickening or endobronchial lesions. Interval or post-screen carcinomas without explanation other than human errors are rare. (orig.)

  18. Molecular screening in galactosemia

    Energy Technology Data Exchange (ETDEWEB)

    Elsas, L.J.; Singh, R.; Fernhoff, P.M. [Emory Univ., Atlanta, GA (United States)] [and others

    1994-09-01

    Classical galactosemia (G/G) is caused by the absence of galactose-1-phosphate uridyl transferase (GALT) activity while the Duarte allele produces partial impairment and a specific biochemical phenotype. Cloning and sequencing of the human GALT gene has enabled the identification of prevalent mutations for both Classical and Duarte alleles. The G allele is caused by a Q188R codon mutation in exon 6 in 70% of a Caucasian population while the D allele is caused by an N134D codon mutation in exon 10. Since the Q188R sequence creates a new Hpa II site and the N314D sequence creates a new Sin I site, it is relatively easy to screen for both mutations by multiplex PCR and restriction digest. Here we describe a method for detection of new mutations producing impaired GALT. Patient DNAs are subjected to SSCP (single strand conformational polymorphism) analysis of their 11 GALT exons. Direct sequencing of the exons targeted by SSCP has revealed many codon changes: IVSC 956 (a splice acceptor site loss), S135L, V151A, E203K, A320T, and Y323D. Two of these codon changes, V151A and S135L, have been confirmed as mutations by finding impaired GALT activity in a yeast expression system. We conclude that molecular screening of GALT DNA will clarify the structural biology of GALT and the pathophysiology of galactosemia.

  19. Screening EEG in Aircrew Selection: Clinical Aerospace Neurology Perspective

    Science.gov (United States)

    Clark, Jonathan B.; Riley, Terrence

    2001-01-01

    As clinical aerospace neurologists we do not favor using screening EEG in pilot selection on unselected and otherwise asymptomatic individuals. The role of EEG in aviation screening should be as an adjunct to diagnosis, and the decision to disqualify a pilot should never be based solely on the EEG. Although a policy of using a screening EEG in an unselected population might detect an individual with a potentially increased relative risk, it would needlessly exclude many applicants who would probably never have a seizure. A diagnostic test performed on an asymptomatic individual without clinical indications, in a population with a low prevalence of disease (seizure) may be of limited or possibly detrimental value. We feel that rather than do EEGs on all candidates, a better approach would be to perform an EEG for a specific indication, such as family history of seizure, single convulsion (seizure) , history of unexplained loss of consciousness or head injury. Routine screening EEGs in unselected aviation applications are not done without clinical indication in the U.S. Air Force, Navy, or NASA. The USAF discontinued routine screening EEGs for selection in 1978, the U.S. Navy discontinued it in 1981 , and NASA discontinued it in 1995. EEG as an aeromedical screening tool in the US Navy dates back to 1939. The US Navy routinely used EEGs to screen all aeromedical personnel from 1961 to 1981. The incidence of epileptiform activity on EEG in asymptomatic flight candidates ranges from 0.11 to 2.5%. In 3 studies of asymptomatic flight candidates with epileptiform activity on EEG followed for 2 to 15 years, 1 of 31 (3.2%), 1 of 30 (3.3%), and 0 of 14 (0%) developed a seizure, for a cumulative risk of an individual with an epileptiform EEG developing a seizure of 2.67% (2 in 75). Of 28,658 student naval aviation personnel screened 31 had spikes and/or slow waves on EEG, and only 1 later developed a seizure. Of the 28,627 who had a normal EEG, 4 later developed seizures, or

  20. Prostate cancer mortality reduction by prostate-specific antigen-based screening adjusted for nonattendance and contamination in the European Randomised Study of Screening for Prostate Cancer (ERSPC).

    Science.gov (United States)

    Roobol, Monique J; Kerkhof, Melissa; Schröder, Fritz H; Cuzick, Jack; Sasieni, Peter; Hakama, Matti; Stenman, Ulf Hakan; Ciatto, Stefano; Nelen, Vera; Kwiatkowski, Maciej; Lujan, Marcos; Lilja, Hans; Zappa, Marco; Denis, Louis; Recker, Franz; Berenguer, Antonio; Ruutu, Mirja; Kujala, Paula; Bangma, Chris H; Aus, Gunnar; Tammela, Teuvo L J; Villers, Arnauld; Rebillard, Xavier; Moss, Sue M; de Koning, Harry J; Hugosson, Jonas; Auvinen, Anssi

    2009-10-01

    Prostate-specific antigen (PSA) based screening for prostate cancer (PCa) has been shown to reduce prostate specific mortality by 20% in an intention to screen (ITS) analysis in a randomised trial (European Randomised Study of Screening for Prostate Cancer [ERSPC]). This effect may be diluted by nonattendance in men randomised to the screening arm and contamination in men randomised to the control arm. To assess the magnitude of the PCa-specific mortality reduction after adjustment for nonattendance and contamination. We analysed the occurrence of PCa deaths during an average follow-up of 9 yr in 162,243 men 55-69 yr of age randomised in seven participating centres of the ERSPC. Centres were also grouped according to the type of randomisation (ie, before or after informed written consent). Nonattendance was defined as nonattending the initial screening round in ERSPC. The estimate of contamination was based on PSA use in controls in ERSPC Rotterdam. Relative risks (RRs) with 95% confidence intervals (CIs) were compared between an ITS analysis and analyses adjusting for nonattendance and contamination using a statistical method developed for this purpose. In the ITS analysis, the RR of PCa death in men allocated to the intervention arm relative to the control arm was 0.80 (95% CI, 0.68-0.96). Adjustment for nonattendance resulted in a RR of 0.73 (95% CI, 0.58-0.93), and additional adjustment for contamination using two different estimates led to estimated reductions of 0.69 (95% CI, 0.51-0.92) to 0.71 (95% CI, 0.55-0.93), respectively. Contamination data were obtained through extrapolation of single-centre data. No heterogeneity was found between the groups of centres. PSA screening reduces the risk of dying of PCa by up to 31% in men actually screened. This benefit should be weighed against a degree of overdiagnosis and overtreatment inherent in PCa screening.

  1. Calibration of Single High Purity Germanium Detector for Whole Body Counter

    International Nuclear Information System (INIS)

    Taha, T.M.; Morsi, T.M.

    2009-01-01

    A new Accuscan II single germanium detector for whole body counter was installed in NRC (Egypt). The current paper concerned on calibration of single high purity germanium detector for whole body counter. Physical parameters affecting on performance of whole body counter such as linearity, minimum detectable activity and source detector distance, SDD were investigated. Counting efficiencies for the detector have been investigated in rear wall, fixed diagnostic position in air. Counting efficiencies for organ compartments such as thyroid, lung, upper and lower gastrointestinal tract have been investigated using transfer phantom in fixed diagnostic and screening positions respectively. The organ compartment efficiencies in screening geometry were higher than that value of diagnostic geometry by a factor of three. The committed dose equivalents of I-131 in thyroid were ranged from 0.073 ± 0.004 to 1.73±0.09 mSv and in lung was 0.02±0.001 mSv

  2. A Rare Case of Malonic Aciduria Diagnosed by Newborn Screening in Qatar

    Directory of Open Access Journals (Sweden)

    Mamatha Ramaswamy

    2017-03-01

    Full Text Available Malonic aciduria is a rare autosomal recessive organic acid disorder. With the widespread use of tandem mass spectrometry for analysis of the amino acid/acylcarnitine profile on dried blood spots for newborn screening (NBS, this condition can be readily diagnosed and can be included in the organic acid screen in NBS programs. In Qatar, we report the first case of an asymptomatic baby screened and diagnosed with malonic aciduria through NBS. This patient has a genetic variant of malonyl-CoA decarboxylase that has not been previously reported in the literature. This condition should be differentiated from a similar disorder, combined malonic and methylmalonic aciduria. The clinical phenotype of malonic aciduria is variable and the pathophysiology is not fully understood. There is no established guidance or recommendations regarding the appropriate treatment regimen, dietary therapy or regular follow-up of these patients. Most available evidence for treatment is based on a single study or case report.

  3. REopt Screenings Catalyze Development of Hundreds of Megawatts of Renewable Energy for Federal Agencies

    Energy Technology Data Exchange (ETDEWEB)

    None

    2017-04-26

    The Federal Energy Management Program (FEMP) offers renewable energy project assistance to federal agencies, which often begins with a desktop screening to develop a prioritized portfolio of project opportunities. FEMP uses the National Renewable Energy Laboratory's REopt energy planning platform to screen potential renewable energy opportunities at a single site or across a range of sites. REopt helps organizations prioritize the most economi­cally and technically viable projects for further study and identifies the size and mix of technologies that meet the orga­nization's goals at minimum cost, along with the optimal operating strategies.

  4. Toward Joint Hypothesis-Tests Seismic Event Screening Analysis: Ms|mb and Event Depth

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Dale [Los Alamos National Laboratory; Selby, Neil [AWE Blacknest

    2012-08-14

    Well established theory can be used to combine single-phenomenology hypothesis tests into a multi-phenomenology event screening hypothesis test (Fisher's and Tippett's tests). Commonly used standard error in Ms:mb event screening hypothesis test is not fully consistent with physical basis. Improved standard error - Better agreement with physical basis, and correctly partitions error to include Model Error as a component of variance, correctly reduces station noise variance through network averaging. For 2009 DPRK test - Commonly used standard error 'rejects' H0 even with better scaling slope ({beta} = 1, Selby et al.), improved standard error 'fails to rejects' H0.

  5. The population impact of human papillomavirus/cytology cervical cotesting at 3-year intervals: Reduced cervical cancer risk and decreased yield of precancer per screen.

    Science.gov (United States)

    Silver, Michelle I; Schiffman, Mark; Fetterman, Barbara; Poitras, Nancy E; Gage, Julia C; Wentzensen, Nicolas; Lorey, Thomas; Kinney, Walter K; Castle, Philip E

    2016-12-01

    The objective of cervical screening is to detect and treat precancer to prevent cervical cancer mortality and morbidity while minimizing overtreatment of benign human papillomavirus (HPV) infections and related minor abnormalities. HPV/cytology cotesting at extended 5-year intervals currently is a recommended screening strategy in the United States, but the interval extension is controversial. In the current study, the authors examined the impact of a decade of an alternative, 3-year cotesting, on rates of precancer and cancer at Kaiser Permanente Northern California. The effect on screening efficiency, defined as numbers of cotests/colposcopy visits needed to detect a precancer, also was considered. Two cohorts were defined. The "open cohort" included all women screened at least once during the study period; > 1 million cotests were performed. In a fixed "long-term screening cohort," the authors considered the cumulative impact of repeated screening at 3-year intervals by restricting the cohort to women first cotested in 2003 through 2004 (ie, no women entering screening later were added to this group). Detection of cervical intraepithelial neoplasia 3/adenocarcinoma in situ (CIN3/AIS) increased in the open cohort (2004-2006: 82.0/100,000 women screened; 2007-2009: 140.6/100,000 women screened; and 2010-2012: 126.0/100,000 women screened); cancer diagnoses were unchanged. In the long-term screening cohort, the detection of CIN3/AIS increased and then decreased to the original level (2004-2006: 80.5/100,000 women screened; 2007-2009: 118.6/100,000 women screened; and 2010-2012: 84.9./100,000 women screened). The number of cancer diagnoses was found to decrease. When viewed in terms of screening efficiency, the number of colposcopies performed to detect a single case of CIN3/AIS increased in the cohort with repeat screening. Repeated cotesting at a 3-year interval eventually lowers population rates of precancer and cancer. However, a greater number of

  6. Cancer Screening Considerations and Cancer Screening Uptake for Lesbian, Gay, Bisexual, and Transgender Persons.

    Science.gov (United States)

    Ceres, Marc; Quinn, Gwendolyn P; Loscalzo, Matthew; Rice, David

    2018-02-01

    To describe the current state of cancer screening and uptake for lesbian, gay, bisexual, and transgender (LGBT) persons and to propose cancer screening considerations for LGBT persons. Current and historic published literature on cancer screening and LGBT cancer screening; published national guidelines. Despite known cancer risks for members of the LGBT community, cancer screening rates are often low, and there are gaps in screening recommendations for LGBT persons. We propose evidence-based cancer screening considerations derived from the current literature and extant cancer screening recommendations. The oncology nurse plays a key role in supporting patient preventive care and screening uptake through assessment, counseling, education, advocacy, and intervention. As oncology nurses become expert in the culturally competent care of LGBT persons, they can contribute to the improvement of quality of care and overall well-being of this health care disparity population. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Vibration characteristics of an inclined flip-flow screen panel in banana flip-flow screens

    Science.gov (United States)

    Xiong, Xiaoyan; Niu, Linkai; Gu, Chengxiang; Wang, Yinhua

    2017-12-01

    A banana flip-flow screen is an effective solution for the screening of high-viscosity, high-water and fine materials. As one of the key components, the vibration characteristics of the inclined flip-flow screen panel largely affects the screen performance and the processing capacity. In this paper, a mathematical model for the vibration characteristic of the inclined flip-flow screen panel is proposed based on Catenary theory. The reasonability of Catenary theory in analyzing the vibration characteristic of flip-flow screen panels is verified by a published experiment. Moreover, the effects of the rotation speed of exciters, the incline angle, the slack length and the characteristics of the screen on the vertical deflection, the vertical velocity and the vertical acceleration of the screen panel are investigated parametrically. The results show that the rotation speed of exciters, the incline angle, the slack length and the characteristics of the screen have significant effects on the vibrations of an inclined flip-flow screen panel, and these parameters should be optimized.

  8. Study of spatial resolution of YAG:Ce cathodoluminescent imaging screens

    Czech Academy of Sciences Publication Activity Database

    Schauer, Petr; Bok, Jan

    2013-01-01

    Roč. 308, 1 August (2013), s. 68-73 ISSN 0168-583X R&D Projects: GA TA ČR TE01020118; GA ČR GAP102/10/1410; GA MŠk EE.2.3.20.0103 Institutional support: RVO:68081731 Keywords : Spatial resolution * Imaging screen * Electron microscope * Cathodoluminescence * YAG:Ce single crystal * Line spread function * Modulation transfer function Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.186, year: 2013

  9. The population impact of HPV/cytology cervical cotesting at 3-year intervals: reduced cervical cancer risk and decreased yield of precancer per screen

    Science.gov (United States)

    Silver, Michelle I.; Schiffman, Mark; Fetterman, Barbara; Poitras, Nancy; Gage, Julia C.; Wentzensen, Nicolas; Lorey, Thomas; Kinney, Walter; Castle, Philip E.

    2016-01-01

    Background Cervical screening aims to detect and treat precancer to prevent cervical cancer mortality and morbidity, while minimizing overtreatment of benign human papillomavirus (HPV) infections and related minor abnormalities. HPV/cytology cotesting at extended 5-year intervals is now a recommended screening strategy in the US, but the interval extension is controversial. We studied the impact of a decade of an alternative, 3-year cotesting, on rates of precancer and cancer at Kaiser Permanente Northern California. We also considered the effect on screening efficiency, defined as numbers of cotests/colposcopy visits needed to detect a precancer. Methods Two cohorts were defined. The “open cohort” included all women screened at least once during the study period; >1 million cotests were performed. In a fixed “long-term screening cohort”, we considered the cumulative impact of repeated screening at 3-year intervals by restricting to women first cotested in 2003–4 (i.e., no women entering screening later were added to this group). Results Detection of CIN3/AIS increased in the open cohort (2004–6, 82.0/100,000 women screened; 2007–9, 140.6/100,000; and 2010–12, 126.0/100,000); cancer diagnoses were unchanged. In the long-term screening cohort, detection of CIN3/AIS increased then decreased to the original level (2004–6, 80.5/100,000; 2007–9, 118.6/100,000; and 2010–2, 84.9/100,000). Cancer diagnoses decreased. Seen in terms of screening efficiency, the number of colposcopies performed todetect a single CIN3/AIS increased in the cohort with repeat screening. Conclusion Repeated cotesting at a 3-year interval eventually lowers population rates of precancer and cancer; however, a greater number of colposcopies is required to detect a single precancer. PMID:27657992

  10. Screen Practice in Curating

    DEFF Research Database (Denmark)

    Toft, Tanya Søndergaard

    2014-01-01

    During the past one and a half decade, a curatorial orientation towards "screen practice" has expanded the moving image and digital art into the public domain, exploring alternative artistic uses of the screen. The emergence of urban LED screens in the late 1990s provided a new venue that allowed...... for digital art to expand into public space. It also offered a political point of departure, inviting for confrontation with the Spectacle and with the politics and ideology of the screen as a mass communication medium that instrumentalized spectator positions. In this article I propose that screen practice...... to the dispositif of screen practice in curating, resulting in a medium-based curatorial discourse. With reference to the nomadic exhibition project Nordic Outbreak that I co-curated with Nina Colosi in 2013 and 2014, I suggest that the topos of the defined visual display area, frequently still known as "the screen...

  11. Can laptops be left inside passenger bags if motion imaging is used in X-ray security screening?

    Science.gov (United States)

    Mendes, Marcia; Schwaninger, Adrian; Michel, Stefan

    2013-01-01

    This paper describes a study where a new X-ray machine for security screening featuring motion imaging (i.e., 5 views of a bag are shown as an image sequence) was evaluated and compared to single view imaging available on conventional X-ray screening systems. More specifically, it was investigated whether with this new technology X-ray screening of passenger bags could be enhanced to such an extent that laptops could be left inside passenger bags, without causing a significant impairment in threat detection performance. An X-ray image interpretation test was created in four different versions, manipulating the factors packing condition (laptop and bag separate vs. laptop in bag) and display condition (single vs. motion imaging). There was a highly significant and large main effect of packing condition. When laptops and bags were screened separately, threat item detection was substantially higher. For display condition, a medium effect was observed. Detection could be slightly enhanced through the application of motion imaging. There was no interaction between display and packing condition, implying that the high negative effect of leaving laptops in passenger bags could not be fully compensated by motion imaging. Additional analyses were carried out to examine effects depending on different threat categories (guns, improvised explosive devices, knives, others), the placement of the threat items (in bag vs. in laptop) and viewpoint (easy vs. difficult view). In summary, although motion imaging provides an enhancement, it is not strong enough to allow leaving laptops in bags for security screening.

  12. Can laptops be left inside passenger bags if motion imaging is used in X-ray security screening?

    Directory of Open Access Journals (Sweden)

    Marcia eMendes

    2013-10-01

    Full Text Available This paper describes a study where a new X-ray machine for security screening featuring motion imaging (i.e. 5 views of a bag are shown as an image sequence was evaluated and compared to single view imaging available on conventional X-ray screening systems. More specifically, it was investigated whether with this new technology X-ray screening of passenger bags could be enhanced to such an extent that laptops could be left inside passenger bags, without causing a significant impairment in threat detection performance. An X-ray image interpretation test was created in four different versions, manipulating the factors packing condition (laptop and bag separate vs. laptop in bag and display condition (single vs. motion imaging. There was a highly significant and large main effect of packing condition. When laptops and bags were screened separately, threat item detection was substantially higher. For display condition, a medium effect was observed. Detection could be slightly enhanced through the application of motion imaging. There was no interaction between display and packing condition, implying that the high negative effect of leaving laptops in passenger bags could not be fully compensated by motion imaging. Additional analyses were carried out to examine effects depending on different threat categories (guns, improvised explosive devices, knives, others, the placement of the threat items (in bag vs. in laptop and viewpoint (easy vs. difficult view. In summary, although motion imaging provides an enhancement, it is not strong enough to allow leaving laptops in bags for security screening.

  13. An in vitro tag-and-modify protein sample generation method for single-molecule fluorescence resonance energy transfer.

    Science.gov (United States)

    Hamadani, Kambiz M; Howe, Jesse; Jensen, Madeleine K; Wu, Peng; Cate, Jamie H D; Marqusee, Susan

    2017-09-22

    Biomolecular systems exhibit many dynamic and biologically relevant properties, such as conformational fluctuations, multistep catalysis, transient interactions, folding, and allosteric structural transitions. These properties are challenging to detect and engineer using standard ensemble-based techniques. To address this drawback, single-molecule methods offer a way to access conformational distributions, transient states, and asynchronous dynamics inaccessible to these standard techniques. Fluorescence-based single-molecule approaches are parallelizable and compatible with multiplexed detection; to date, however, they have remained limited to serial screens of small protein libraries. This stems from the current absence of methods for generating either individual dual-labeled protein samples at high throughputs or protein libraries compatible with multiplexed screening platforms. Here, we demonstrate that by combining purified and reconstituted in vitro translation, quantitative unnatural amino acid incorporation via AUG codon reassignment, and copper-catalyzed azide-alkyne cycloaddition, we can overcome these challenges for target proteins that are, or can be, methionine-depleted. We present an in vitro parallelizable approach that does not require laborious target-specific purification to generate dual-labeled proteins and ribosome-nascent chain libraries suitable for single-molecule FRET-based conformational phenotyping. We demonstrate the power of this approach by tracking the effects of mutations, C-terminal extensions, and ribosomal tethering on the structure and stability of three protein model systems: barnase, spectrin, and T4 lysozyme. Importantly, dual-labeled ribosome-nascent chain libraries enable single-molecule co-localization of genotypes with phenotypes, are well suited for multiplexed single-molecule screening of protein libraries, and should enable the in vitro directed evolution of proteins with designer single-molecule conformational

  14. Incremental Value of Repeated Risk Factor Measurements for Cardiovascular Disease Prediction in Middle-Aged Korean Adults: Results From the NHIS-HEALS (National Health Insurance System-National Health Screening Cohort).

    Science.gov (United States)

    Cho, In-Jeong; Sung, Ji Min; Chang, Hyuk-Jae; Chung, Namsik; Kim, Hyeon Chang

    2017-11-01

    Increasing evidence suggests that repeatedly measured cardiovascular disease (CVD) risk factors may have an additive predictive value compared with single measured levels. Thus, we evaluated the incremental predictive value of incorporating periodic health screening data for CVD prediction in a large nationwide cohort with periodic health screening tests. A total of 467 708 persons aged 40 to 79 years and free from CVD were randomly divided into development (70%) and validation subcohorts (30%). We developed 3 different CVD prediction models: a single measure model using single time point screening data; a longitudinal average model using average risk factor values from periodic screening data; and a longitudinal summary model using average values and the variability of risk factors. The development subcohort included 327 396 persons who had 3.2 health screenings on average and 25 765 cases of CVD over 12 years. The C statistics (95% confidence interval [CI]) for the single measure, longitudinal average, and longitudinal summary models were 0.690 (95% CI, 0.682-0.698), 0.695 (95% CI, 0.687-0.703), and 0.752 (95% CI, 0.744-0.760) in men and 0.732 (95% CI, 0.722-0.742), 0.735 (95% CI, 0.725-0.745), and 0.790 (95% CI, 0.780-0.800) in women, respectively. The net reclassification index from the single measure model to the longitudinal average model was 1.78% in men and 1.33% in women, and the index from the longitudinal average model to the longitudinal summary model was 32.71% in men and 34.98% in women. Using averages of repeatedly measured risk factor values modestly improves CVD predictability compared with single measurement values. Incorporating the average and variability information of repeated measurements can lead to great improvements in disease prediction. URL: https://www.clinicaltrials.gov. Unique identifier: NCT02931500. © 2017 American Heart Association, Inc.

  15. The effects of music on pain and anxiety during screening mammography.

    Science.gov (United States)

    Zavotsky, Kathleen Evanovich; Banavage, Adrienne; James, Patricia; Easter, Kathy; Pontieri-Lewis, Vicky; Lutwin, Lynn

    2014-06-01

    One in four women who are diagnosed with breast cancer die annually, and the single most important way to prevent this is early detection; therefore, women older than 40 years should have an annual screening mammography. Many barriers have been reported that prevent compliance with this recommendation, including lack of insurance, fear, anxiety, pain, worry, and mistrust of the medical community. Nurses are in a position to use creative interventions, such as music therapy, to help minimize barriers. Although this study did not show that music therapy during screening mammograms decreased the amount of pain that the participants experienced, it did suggest that music therapy has the potential to decrease the amount of anxiety. Assisting patients in decreasing anxiety reduces barriers for screening mammography. The literature does suggest that music is a distraction for many populations of patients; however, when patients are faced with the possible diagnosis of breast cancer, it may be difficult to find an intervention to distract a woman's mind, which was supported by the findings of this study.

  16. Breast cancer screening-opportunistic use of registry and linked screening data for local evaluation.

    Science.gov (United States)

    Roder, David; Farshid, Gelareh; Gill, Grantley; Kollias, Jim; Koczwara, Bogda; Karapetis, Chris; Adams, Jacqui; Joshi, Rohit; Keefe, Dorothy; Powell, Kate; Fusco, Kellie; Eckert, Marion; Buckley, Elizabeth; Beckmann, Kerri

    2017-06-01

    Screening has been found to reduce breast cancer mortality at a population level in Australia, but these studies did not address local settings where numbers of deaths would generally have been too low for evaluation. Clinicians, administrators, and consumer groups are also interested in local service outcomes. We therefore use more common prognostic and treatment measures and survivals to gain evidence of screening effects among patients attending 4 local hospitals for treatment. To compare prognostic, treatment, and survival measures by screening history to determine whether expected screening effects are occurring. Employing routine clinical registry and linked screening data to investigate associations of screening history with these measures, using unadjusted and adjusted analyses. Screened women had a 10-year survival from breast cancer of 92%, compared with 78% for unscreened women; and 79% of screened surgical cases had breast conserving surgery compared with 64% in unscreened women. Unadjusted analyses indicated that recently screened cases had earlier tumor node metastasis stages, smaller diameters, less nodal involvement, better tumor differentiation, more oestrogen and progesterone receptor positive lesions, more hormone therapy, and less chemotherapy. Radiotherapy tended to be more common in screening participants. More frequent use of adjunctive radiotherapy applied when breast conserving surgery was used. Results confirm the screening effects expected from the scientific literature and demonstrate the value of opportunistic use of available registry and linked screening data for indicating to local health administrations, practitioners, and consumers whether local screening services are having the effects expected. © 2016 John Wiley & Sons, Ltd.

  17. Screening for carcinoma in situ in the contralateral testicle in patients with testicular cancer: a population-based study.

    Science.gov (United States)

    Kier, M G G; Lauritsen, J; Almstrup, K; Mortensen, M S; Toft, B G; Rajpert-De Meyts, E; Skakkebaek, N E; Rørth, M; von der Maase, H; Agerbaek, M; Holm, N V; Andersen, K K; Dalton, S O; Johansen, C; Daugaard, G

    2015-04-01

    Screening programmes for contralateral carcinoma in situ (CIS) testis in patients with unilateral germ-cell cancer (GCC) have never been evaluated. We investigated the effect of screening for contralateral CIS in a large nation-wide, population-based study. A contralateral single-site biopsy was offered to 4130 patients in whom GCC had been diagnosed in 1984-2007 (screened cohort); 462 patients in whom GCC was diagnosed in 1984-1988 comprised the unscreened cohort. Cases with CIS were offered radiotherapy. Initially CIS-negative biopsies in patients with metachronous GCC were revised according to today's standards. Risk for metachronous GCC was estimated using cumulative incidence and the Cox proportional hazards model. In the screened cohort, contralateral CIS was found in 181 (4.4%) patients. The cumulative incidence of metachronous GCC after 20 years was 1.9% in the screened cohort and 3.1% in the unscreened cohort (P = 0.097), hazard ratio (HR) for the unscreened cohort: 1.59 (P = 0.144). Expert revision with contemporary methodology of CIS-negative biopsy samples from patients with metachronous cancer revealed CIS in 17 out of 45 (38%) cases. Decreased risks for metachronous GCC were related to older age at diagnosis (HR 0.52 per 10 years, P testicular cancer showed no significant difference in the risk for metachronous GCC between a screened and an unscreened cohort. Single-site biopsy including modern immunohistochemistry does not identify all cases of CIS. © The Author 2014. Published by Oxford University Press on behalf of the European Society for Medical Oncology. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  18. A fully automated primary screening system for the discovery of therapeutic antibodies directly from B cells.

    Science.gov (United States)

    Tickle, Simon; Howells, Louise; O'Dowd, Victoria; Starkie, Dale; Whale, Kevin; Saunders, Mark; Lee, David; Lightwood, Daniel

    2015-04-01

    For a therapeutic antibody to succeed, it must meet a range of potency, stability, and specificity criteria. Many of these characteristics are conferred by the amino acid sequence of the heavy and light chain variable regions and, for this reason, can be screened for during antibody selection. However, it is important to consider that antibodies satisfying all these criteria may be of low frequency in an immunized animal; for this reason, it is essential to have a mechanism that allows for efficient sampling of the immune repertoire. UCB's core antibody discovery platform combines high-throughput B cell culture screening and the identification and isolation of single, antigen-specific IgG-secreting B cells through a proprietary technique called the "fluorescent foci" method. Using state-of-the-art automation to facilitate primary screening, extremely efficient interrogation of the natural antibody repertoire is made possible; more than 1 billion immune B cells can now be screened to provide a useful starting point from which to identify the rare therapeutic antibody. This article will describe the design, construction, and commissioning of a bespoke automated screening platform and two examples of how it was used to screen for antibodies against two targets. © 2014 Society for Laboratory Automation and Screening.

  19. Modeling fiber motion in a pulp pressure screen: the effect of slot shape

    International Nuclear Information System (INIS)

    Dong, S.; Salcudean, M.; Gartshore, I.

    2003-01-01

    A pressure screen is a piece of equipment in the pulp and paper industry used either to remove contaminants from the pulp suspension or to separate fibers having different properties. Contaminants such as fiber bundles, bark and plastic specks are introduced when fibers are separated from the wood by mechanical or chemical pulping processes. Contaminants significantly affect the strength and smoothness of the paper and must be removed before the final paper is produced. The screen plate is a critical part of the pressure screen and its design is the key to screen performance. This paper uses a new and comprehensive CFD simulation tool to examine the flow and fiber behavior in a single slot screen having any reasonable slot shape. -This simulation tool includes three coupled models: first, the flow model solves the Reynolds Averaged Navier-Stokes (RANS) equation using the standard k - ε turbulence model to predict the flow field in the equipment. Second, a three-dimensional flexible fiber model is used to track the fiber trajectory in the screen. Third, a very general wall model is used to deal with the case when a fiber touches the equipment wall. The simulated results show that the slot shape has a critical influence on fiber behavior and screen performance. Three general slot shapes were investigated: the smooth slot, the step-step contour slot and slope-slope contour slot. Of these the slope-slope contour slot provides the best passage for the fibers with a length of 1mm and 3mm. (author)

  20. Molecular HIV screening.

    Science.gov (United States)

    Bourlet, Thomas; Memmi, Meriam; Saoudin, Henia; Pozzetto, Bruno

    2013-09-01

    Nuclear acid testing is more and more used for the diagnosis of infectious diseases. This paper focuses on the use of molecular tools for HIV screening. The term 'screening' will be used under the meaning of first-line HIV molecular techniques performed on a routine basis, which excludes HIV molecular tests designed to confirm or infirm a newly discovered HIV-seropositive patient or other molecular tests performed for the follow-up of HIV-infected patients. The following items are developed successively: i) presentation of the variety of molecular tools used for molecular HIV screening, ii) use of HIV molecular tools for the screening of blood products, iii) use of HIV molecular tools for the screening of organs and tissue from human origin, iv) use of HIV molecular tools in medically assisted procreation and v) use of HIV molecular tools in neonates from HIV-infected mothers.

  1. Newborn screening by tandem mass spectrometry: ethical and social issues.

    Science.gov (United States)

    Avard, Denise; Vallance, Hilary; Greenberg, Cheryl; Potter, Beth

    2007-01-01

    Emerging technologies like Tandem Mass Spectrometry (TMS) enable multiple tests on a single blood sample and allow the expansion of Newborn Screening (NBS) to include various metabolic diseases. Introducing TMS for NBS raises important social and ethical questions: what are the criteria for adding disorders to screening panels? What evidence justifies expansion of screening? How can equity in NBS access and standards be ensured? How can policy standards be set, given the multiplicity of stakeholders? To address emerging issues, policy-makers, patient advocates, clinicians and researchers had a workshop during the 2005 Garrod Symposium. The participants received a summary of the discussion and understood the workshop's goal was to provide a basis for further discussion. This article contributes to this ongoing discussion. Several proposed recommendations assert the centrality of including social and ethical issues in the assessment of whether or not to introduce TMS. The article outlines five key recommendations for advancing the NBS agenda: national public health leadership; transparency; increased national consistency in NBS strategy, including minimum standards; collaboration between the federal and provincial/territorial governments and diverse stakeholders; and supporting research and/or programs based on effectiveness, which integrate ethical and social issues into assessment.

  2. Colorectal Cancer Screening

    OpenAIRE

    Quintero, Enrique; Saito, Yutaka; Hassan, Cessare; Senore, Carlo

    2012-01-01

    Colorectal cancer, which is the leading cancer in Singapore, can be prevented by increased use of screening and polypectomy. A range of screening strategies such as stool-based tests, flexible sigmoidoscopy, colonoscopy and computed tomography colonography are available, each with different strengths and limitations. Primary care physicians should discuss appropriate screening modalities with their patients, tailored to their individual needs. Physicians, patients and the government should wo...

  3. JOURNAL CLUB: Plagiarism in Manuscripts Submitted to the AJR: Development of an Optimal Screening Algorithm and Management Pathways.

    Science.gov (United States)

    Taylor, Donna B

    2017-04-01

    The objective of this study was to investigate the incidence of plagiarism in a sample of manuscripts submitted to the AJR using CrossCheck, develop an algorithm to identify significant plagiarism, and formulate management pathways. A sample of 110 of 1610 (6.8%) manuscripts submitted to AJR in 2014 in the categories of Original Research or Review were analyzed using CrossCheck and manual assessment. The overall similarity index (OSI), highest similarity score from a single source, whether duplication was from single or multiple origins, journal section, and presence or absence of referencing the source were recorded. The criteria outlined by the International Committee of Medical Journal Editors were the reference standard for identifying manuscripts containing plagiarism. Statistical analysis was used to develop a screening algorithm to maximize sensitivity and specificity for the detection of plagiarism. Criteria for defining the severity of plagiarism and management pathways based on the severity of the plagiarism were determined. Twelve manuscripts (10.9%) contained plagiarism. Nine had an OSI excluding quotations and references of less than 20%. In seven, the highest similarity score from a single source was less than 10%. The highest similarity score from a single source was the work of the same author or authors in nine. Common sections for duplication were the Materials and Methods, Discussion, and abstract. Referencing the original source was lacking in 11. Plagiarism was undetected at submission in five of these 12 articles; two had been accepted for publication. The most effective screening algorithm was to average the OSI including quotations and references and the highest similarity score from a single source and to submit manuscripts with an average value of more than 12% for further review. The current methods for detecting plagiarism are suboptimal. A new screening algorithm is proposed.

  4. The Prevalence of CKD in Rural Canadian Indigenous Peoples: Results From the First Nations Community Based Screening to Improve Kidney Health and Prevent Dialysis (FINISHED) Screen, Triage, and Treat Program.

    Science.gov (United States)

    Komenda, Paul; Lavallee, Barry; Ferguson, Thomas W; Tangri, Navdeep; Chartrand, Caroline; McLeod, Lorraine; Gordon, Audrey; Dart, Allison; Rigatto, Claudio

    2016-10-01

    Indigenous Canadians have high rates of risk factors for chronic kidney disease (CKD), in particular diabetes. Furthermore, they have increased rates of complications associated with CKD, such as kidney failure and vascular disease. Our objective was to describe the prevalence of CKD in this population. Cross-sectional cohort. Indigenous (First Nations) Canadians 18 years or older screened as part of the First Nations Community Based Screening to Improve Kidney Health and Prevent Dialysis (FINISHED) project, an initiative completed in 2015 that accomplished community-wide screening in 11 rural communities in Manitoba, Canada. Indigenous ethnicity and geographic location (communities accessible by road compared with those accessible only by air). Prevalence of CKD, presumed based on a single ascertainment of urine albumin-creatinine ratio (UACR) ≥ 30mg/g and/or estimated glomerular filtration rate (eGFR)indigenous Canadians in comparison to the general population and a prevalence of severely increased albuminuria that was 5-fold higher. This is comparable to patients with diabetes and/or hypertension. Public health strategies to screen, triage, and treat all Canadian indigenous peoples with CKD should be considered. Copyright © 2016 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  5. Light emission efficiency and imaging properties of YAP:Ce granular phosphor screens

    International Nuclear Information System (INIS)

    Kalivas, N.; Valais, I.; Nikolopoulos, D.; Konstantinidis, A.; Cavouras, D.; Kandarakis, I.; Gaitanis, A.; Nomicos, C.D.; Panayiotakis, G.

    2007-01-01

    Phosphor materials are used in medical imaging combined with radiographic film or other photodetectors. Cerium (Ce 3+ ) -doped scintillators are of particular interest for medical imaging, because of their very fast response. YAP:Ce scintillator-based image detectors have already been evaluated in single-crystal form and under conditions of positron emission tomography and synchrotron or γ-ray irradiation. Furthermore, YAP:Ce phosphor has been evaluated in conjunction with radiographic films. The present work reports experimental and theoretical data concerning the light output absolute luminescence efficiency (AE) of the YAP:Ce screens under irradiation conditions employed in medical X-ray projection imaging (i.e., in diagnostic radiology). projection imaging (i.e., in diagnostic radiology). YAP:Ce phosphor screens with surface densities ranging between 53 and 110 mg/cm 2 were prepared by sedimentation on fused silica substrates in our laboratory. The resulted surface density of the screens was determined by dividing the phosphor mass deposited on the screen surface with the area of the surface. Additionally this work addresses the imaging performance of YAP:Ce by estimation of the detective quantum efficiency (DQE), i.e., the square of the signal to noise ratio transfer. Absolute efficiency was found to decrease with X-ray tube voltage for for YAP:Ce phosphor. The highest experimental efficiency was obtained for the 53.7 mg/cm 2 and 88.0 mg/cm 2 YAP:Ce screens. The highest DQE value was found for the 88.0 mg/cm 2 screen irradiated at 60 kVp. (orig.)

  6. Screen dealing

    International Nuclear Information System (INIS)

    Barlow, J.W.

    1991-01-01

    The screen dealing system provides a facility whereby buyers and sellers of spot thermal coal can make bids and offers via the medium of the Reuters screen. A sale results when a market participant notifies his acceptance of a price to a central dealing desk. Use of the system is available to all genuine participants in the coal trade. This paper reports that it provides a focus for information and for the visible making of coal prices. For years screen trading has been used successfully to trade other commodities. At last coal is being traded electronically. It makes sense. It works. Users like it

  7. Screen time and children

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/patientinstructions/000355.htm Screen time and children To use the sharing features on ... videos is considered unhealthy screen time. Current Screen Time Guidelines Children under age 2 should have no ...

  8. Single cell analysis contemporary research and clinical applications

    CERN Document Server

    Cossarizza, Andrea

    2017-01-01

    This book highlights the current state of the art in single cell analysis, an area that involves many fields of science – from clinical hematology, functional analysis and drug screening, to platelet and microparticle analysis, marine biology and fundamental cancer research. This book brings together an eclectic group of current applications, all of which have a significant impact on our current state of knowledge. The authors of these chapters are all pioneering researchers in the field of single cell analysis. The book will not only appeal to those readers more focused on clinical applications, but also those interested in highly technical aspects of the technologies. All of the technologies identified utilize unique applications of photon detection systems.

  9. New perspectives on preimplantation genetic diagnosis and preimplantation genetic screening

    Directory of Open Access Journals (Sweden)

    Chun-Kai Chen

    2014-06-01

    Full Text Available Preimplantation genetic diagnosis is a procedure that involves the removal of one or more nuclei from oocytes (a polar body or embryos (blastomeres or trophectoderm cells in order to test for problems in genome sequence or chromosomes of the embryo prior to implantation. It provides new hope of having unaffected children, as well as avoiding the necessity of terminating an affected pregnancy for genetic parents who carry an affected gene or have balanced chromosomal status. Polymerase chain reaction-based molecular techniques are the methods used to detect gene defects with a known sequence and X-linked diseases. The indication for using this approach has expanded for couples who are prevented from having babies because they carry a serious genetic disorder to couples with conditions that are not immediately life threatening, such as cancer predisposition genes and Huntington disease. In addition, fluorescent in situ hybridization (FISH has been widely applied for the detection of chromosome abnormalities. FISH allows the evaluation of many chromosomes at the same time, up to 15 chromosome pairs in a single cell. Preimplantation genetic screening, defined as a test that screens for aneuploidy, has been most commonly used in situations of advanced maternal age, a history of recurrent miscarriage, a history of repeated implantation failure, or a severe male factor. Unfortunately, randomized controlled trials have as yet shown no benefit with respect to preimplantation genetic screening using cleavage stage biopsy, which is probably attributable to the high levels of mosaicism at early cleavage stages and the limitations of FISH. Recently, two main types of array-based technology combined with whole genome amplification have been developed for use in preimplantation genetic diagnosis; these are comparative genomic hybridization and single nucleotide polymorphism-based arrays. Both allow the analysis of all chromosomes, and the latter also allows

  10. Screening for abdominalt aortaaneurisme

    DEFF Research Database (Denmark)

    Lindholt, J S; Juul, Svend; Henneberg, E W

    1997-01-01

    rupture. Ultrasonographic screening for AAA takes 10 minutes per scan, and the sensitivity and specificity are high. Ultrasonographic screening for AAA is a reliable, safe and inexpensive method for screening, and screening for AAA is discussed worldwide. One point four percent of deaths among men from 65...... to 80 year of age are caused by ruptured AAA. Screening men over 65 for AAA can theoretically prevent a substantial number of deaths. Our calculations predict one prevented AAA-death per 200-300 scans for a cost of about 4000 DKK per saved year of life. However, cost-benefit analyses are based...... on uncertain assumptions concerning prevalence, incidence and risk of rupture. Therefore a randomized trial screening of 65-73 year old males is taking place in the County of Viborg in Denmark. Udgivelsesdato: 1997-Mar-24...

  11. Virtual colonoscopy - changes for screening examination?

    International Nuclear Information System (INIS)

    Rust, G.F.; Reiser, M.

    2002-01-01

    In principle, virtual colonoscopy is capable to be used as method for early detection of colorectal cancer (CRC), even if the accuracy of the method and radiation exposure are matters discussion in the radiological community. Virtual colonoscopy is able to detect any pathology which is relevant for early detection of CRC especially when using multislice CT, but also with single slice CT. The diagnosis of small lesions, less than 7 mm in diameter (polyps and flat lesions) is still problematic as it is in conventional colonoscopy. The exposure to x-rays in asymptomatic patients, without any increased risk of developing cancer is highly problematic and should be reduced to a minimum. Using special post processing filters on the volume dataset it can be shown that a tube current of 20 mAs is sufficient without any loss in accuracy. Measurements on the Alderson-phantom showed, that an effective dose exposure of 1.2 mSv is obtained using these reduced mAs values. It has to be differentiated between virtual colonoscopy for early detection of polyps and CRC in individual patients or as a screening examination of a large population. Virtual colonoscopy as a screening examination necessitates reduction of radiation dose, a high degree of automatisation in 3D reconstructions as well as the assessment of the entire mucosa. High risk patients, whom refuse fibreoptic colonoscopy should undergo virtual colonoscopy. Virtual colonoscopy has a good chance to become an accepted tool for general screening, if efficient dose reduction, complete visualization of the colon mucosa and automatisation of the post processing procedures can be achieved. (orig.) [de

  12. Single-Cell Whole-Genome Amplification and Sequencing: Methodology and Applications.

    Science.gov (United States)

    Huang, Lei; Ma, Fei; Chapman, Alec; Lu, Sijia; Xie, Xiaoliang Sunney

    2015-01-01

    We present a survey of single-cell whole-genome amplification (WGA) methods, including degenerate oligonucleotide-primed polymerase chain reaction (DOP-PCR), multiple displacement amplification (MDA), and multiple annealing and looping-based amplification cycles (MALBAC). The key parameters to characterize the performance of these methods are defined, including genome coverage, uniformity, reproducibility, unmappable rates, chimera rates, allele dropout rates, false positive rates for calling single-nucleotide variations, and ability to call copy-number variations. Using these parameters, we compare five commercial WGA kits by performing deep sequencing of multiple single cells. We also discuss several major applications of single-cell genomics, including studies of whole-genome de novo mutation rates, the early evolution of cancer genomes, circulating tumor cells (CTCs), meiotic recombination of germ cells, preimplantation genetic diagnosis (PGD), and preimplantation genomic screening (PGS) for in vitro-fertilized embryos.

  13. Prenatal Detection of Congenital Heart Diseases: One-Year Survey Performing a Screening Protocol in a Single Reference Center in Brazil

    Directory of Open Access Journals (Sweden)

    Luciane Alves Rocha

    2014-01-01

    Full Text Available Objective. To describe the experience of a tertiary center in Brazil to which patients are referred whose fetuses are at increased risk for congenital heart diseases (CHDs. Methods. This was a cross-sectional observational study. The data was collected prospectively, during the year 2012, through a screening protocol of the fetal heart adapted from the International Society of Ultrasound in Obstetrics and Gynecology (ISUOG guideline. We performed a fetal echocardiogram screening for all pregnant women who were referred to the fetal cardiology outpatient obstetrics clinic of a university hospital. The exams were classified as normal or abnormal. The cases considered abnormal were undergone to a postnatal echocardiogram. We categorized the abnormal fetal heart according to severity in “complex,” “significant,” “minor,” and “others.” Results. We performed 271 fetal heart screening. The incidence of abnormal screenings was 9.96% (27 fetuses. The structural CHD when categorized due to severity showed 48.1% (n=13 of “complex” cases, 18.5% (n=5 “significant” cases, and 7.4% (n=2 “minor” cases. The most common referral reason was by maternal causes (67% followed by fetal causes (33%. The main referral indication was maternal metabolic disease (30%, but there was just one fetus with CHD in such cases (1.2%. CHDs were found in 19/29 fetuses with suspicion of some cardiac abnormality by obstetrician (65.5%. Conclusion. We observed a high rate of CHD in our population. We also found that there was higher incidence of complex cases.

  14. Effect of critical field on screened dielectric breakdown growth

    International Nuclear Information System (INIS)

    Wang Wei.

    1993-10-01

    In this paper we have shown that due to a critical field, the patterns growing in the screened Laplacian field will be affected. When the critical field is zero, there is a transition from a dense growing to single branch of aggregate. At a higher critical field, the pattern shows a spiky-type aggregate, and for a small critical field the transition is cut. For an intermediate critical field, the result shows that below the transition, there no dense structure. (author). 9 refs, 2 figs

  15. Enzymatically Generated CRISPR Libraries for Genome Labeling and Screening.

    Science.gov (United States)

    Lane, Andrew B; Strzelecka, Magdalena; Ettinger, Andreas; Grenfell, Andrew W; Wittmann, Torsten; Heald, Rebecca

    2015-08-10

    CRISPR-based technologies have emerged as powerful tools to alter genomes and mark chromosomal loci, but an inexpensive method for generating large numbers of RNA guides for whole genome screening and labeling is lacking. Using a method that permits library construction from any source of DNA, we generated guide libraries that label repetitive loci or a single chromosomal locus in Xenopus egg extracts and show that a complex library can target the E. coli genome at high frequency. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Breast Cancer Screening

    International Nuclear Information System (INIS)

    Altaf, Fadwa J.

    2004-01-01

    Breast cancer is a very common health problem in Saudi females that can be reduced by early detection through introducing breast cancer screening. Literature review reveals significant reduction in breast cancer incidence and outcome after the beginning of breast cancer screening. The objectives of this article are to highlight the significance of breast cancer screening in different international societies and to write the major guidelines of breast cancer screening in relation to other departments involved with more emphasis on the Pathology Department guidelines in tissue handling, diagnostic criteria and significance of the diagnosis. This article summaries and acknowledges major work carried out before, and recommends similar modified work in order to meet the requirement for the Saudi society. (author)

  17. Stomach (Gastric) Cancer Screening

    Science.gov (United States)

    ... Stomach Cancer Prevention Stomach Cancer Screening Research Stomach (Gastric) Cancer Screening (PDQ®)–Patient Version What is screening? Go ... are called diagnostic tests . General Information About Stomach (Gastric) Cancer Key Points Stomach cancer is a disease in ...

  18. Preimplantation Genetic Screening and Preimplantation Genetic Diagnosis.

    Science.gov (United States)

    Sullivan-Pyke, Chantae; Dokras, Anuja

    2018-03-01

    Preimplantation genetic testing encompasses preimplantation genetic screening (PGS) and preimplantation genetic diagnosis (PGD). PGS improves success rates of in vitro fertilization by ensuring the transfer of euploid embryos that have a higher chance of implantation and resulting in a live birth. PGD enables the identification of embryos with specific disease-causing mutations and transfer of unaffected embryos. The development of whole genome amplification and genomic tools, including single nucleotide polymorphism microarrays, comparative genomic hybridization microarrays, and next-generation sequencing, has led to faster, more accurate diagnoses that translate to improved pregnancy and live birth rates. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Screening vs. non-screening detected colorectal cancer: Differences in pre-therapeutic work up and treatment.

    Science.gov (United States)

    Saraste, D; Martling, A; Nilsson, P J; Blom, J; Törnberg, S; Janson, M

    2017-06-01

    Objectives To compare preoperative staging, multidisciplinary team-assessment, and treatment in patients with screening detected and non-screening detected colorectal cancer. Methods Data on patient and tumour characteristics, staging, multidisciplinary team-assessment and treatment in patients with screening and non-screening detected colorectal cancer from 2008 to 2012 were collected from the Stockholm-Gotland screening register and the Swedish Colorectal Cancer Registry. Results The screening group had a higher proportion of stage I disease (41 vs. 15%; p team-assessed than the non-screening group ( p team-assessed than patients with surgically resected cancers ( p team assessed more extensively than patients with non-screening detected cancers. Staging and multidisciplinary team assessment prior to endoscopic resection was less complete compared with surgical resection. Extensive surgical and (neo)adjuvant treatment was given in stage I disease. Participation in screening reduced the risk of emergency surgery for colorectal cancer.

  20. Highly efficient sources of single indistinguishable photons

    DEFF Research Database (Denmark)

    Gregersen, Niels

    2013-01-01

    be electrically driven. Several design strategies addressing these requirements have been proposed. In the cavity-based source, light emission is controlled using resonant cavity quantum electrodynamics effects, whereas in the waveguide-based source, broadband electric field screening effects are employed......Solid-state sources capable of emitting single photons on demand are of great interest in quantum information applications. Ideally, such a source should emit exactly one photon into the collection optics per trigger, the emitted photons should be indistinguishable and the source should...

  1. Colorectal cancer screening

    OpenAIRE

    Plumb, A. A.; Halligan, S.

    2015-01-01

    Colorectal cancer is a major public health burden worldwide. There is clear-cut evidence that screening will reduce colorectal cancer mortality and the only contentious issue is which screening tool to use. Most evidence points towards screening with fecal occult blood testing. The immunochemical fecal occult blood tests have a higher sensitivity than the guaiac-based tests. In addition, their automation and haemoglobin quantification allows a threshold for colonoscopy to be selected that can...

  2. A high throughput screening assay for identifying glycation inhibitors on MALDI-TOF target.

    Science.gov (United States)

    Zhang, Qiuting; Tu, Zongcai; Wang, Hui; Fan, Liangliang; Huang, Xiaoqin; Xiao, Hui

    2015-03-01

    The Maillard reaction plays an important role in the food industry, however, the deleterious effects generated by the advanced glycation end-products (AGEs) have been well recognized. Many efforts have been made to seek new AGE inhibitors, in particular those natural ones without adverse effect. We have developed a rapid, mass spectrometry based, on-plate screening assay for novel AGE inhibitors. The glycation reaction, inhibition feedback as well as the subsequent MALDI mass spectrometric analysis occurred on one single MALDI plate. At 1:10 M ratio of peptide to sugar, as little as 4h incubation time allowed the screening test to be ready for analysis. DSP, inhibition and IC50 were calculated to evaluate selected inhibitors and resulting inhibition efficiencies were consistent with available references. We demonstrated that this method provide a potential high throughput screening assay to analyze and identify the anti-glycation agents. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. A Screening Tool for Assessing Alcohol Use Risk among Medically Vulnerable Youth.

    Science.gov (United States)

    Levy, Sharon; Dedeoglu, Fatma; Gaffin, Jonathan M; Garvey, Katharine C; Harstad, Elizabeth; MacGinnitie, Andrew; Rufo, Paul A; Huang, Qian; Ziemnik, Rosemary E; Wisk, Lauren E; Weitzman, Elissa R

    2016-01-01

    In an effort to reduce barriers to screening for alcohol use in pediatric primary care, the National Institute on Alcoholism and Alcohol Abuse (NIAAA) developed a two-question Youth Alcohol Screening Tool derived from population-based survey data. It is unknown whether this screening tool, designed for use with general populations, accurately identifies risk among youth with chronic medical conditions (YCMC). This growing population, which comprises nearly one in four youth in the US, faces a unique constellation of drinking-related risks. To validate the NIAAA Youth Alcohol Screening Tool in a population of YCMC, we performed a cross-sectional validation study with a sample of 388 youth ages 9-18 years presenting for routine subspecialty care at a large children's hospital for type 1 diabetes, persistent asthma, cystic fibrosis, inflammatory bowel disease, or juvenile idiopathic arthritis. Participants self-administered the NIAAA Youth Alcohol Screening Tool and the Diagnostic Interview Schedule for Children as a criterion standard measure of alcohol use disorders (AUD). Receiver operating curve analysis was used to determine cut points for identifying youth at moderate and highest risk for an AUD. Nearly one third of participants (n = 118; 30.4%) reported alcohol use in the past year; 86.4% (106) of past year drinkers did not endorse any AUD criteria, 6.8% (n = 8) of drinkers endorsed a single criterion, and 6.8% of drinkers met criteria for an AUD. Using the NIAAA tool, optimal cut points found to identify youth at moderate and highest risk for an AUD were ≥ 6 and ≥12 drinking days in the past year, respectively. The NIAAA Youth Alcohol Screening Tool is highly efficient for detecting alcohol use and discriminating disordered use among YCMC. This brief screen appears feasible for use in specialty care to ascertain alcohol-related risk that may impact adversely on health status and disease management.

  4. REopt Screenings Catalyze Development of Hundreds of Megawatts of Renewable Energy for Federal Agencies

    Energy Technology Data Exchange (ETDEWEB)

    2017-04-24

    The U.S. Department of Energy's (DOE's) Federal Energy Management Program (FEMP) offers project assistance to federal agencies, which often begins with a desktop screening to develop a prioritized portfolio of renewable energy project opportunities. FEMP uses the National Renewable Energy Laboratory's (NREL) REopt energy planning platform to quickly and efficiently screen potential renewable energy opportunities at a single site or across a range of sites. REopt helps organizations prioritize the most economically and technically viable projects for further study, and identifies the size and mix of technologies that meet the organization's goals at minimum cost, along with the optimal operating strategies.

  5. Difficulties encountered managing nodules detected during a computed tomography lung cancer screening program.

    Science.gov (United States)

    Veronesi, Giulia; Bellomi, Massimo; Scanagatta, Paolo; Preda, Lorenzo; Rampinelli, Cristiano; Guarize, Juliana; Pelosi, Giuseppe; Maisonneuve, Patrick; Leo, Francesco; Solli, Piergiorgio; Masullo, Michele; Spaggiari, Lorenzo

    2008-09-01

    The main challenge of screening a healthy population with low-dose computed tomography is to balance the excessive use of diagnostic procedures with the risk of delayed cancer detection. We evaluated the pitfalls, difficulties, and sources of mistakes in the management of lung nodules detected in volunteers in the Cosmos single-center screening trial. A total of 5201 asymptomatic high-risk volunteers underwent screening with multidetector low-dose computed tomography. Nodules detected at baseline or new nodules at annual screening received repeat low-dose computed tomography at 1 year if less than 5 mm, repeat low-dose computed tomography 3 to 6 months later if between 5 and 8 mm, and fluorodeoxyglucose positron emission tomography if more than 8 mm. Growing nodules at the annual screening received low-dose computed tomography at 6 months and computed tomography-positron emission tomography or surgical biopsy according to doubling time, type, and size. During the first year of screening, 106 patients underwent lung biopsy and 91 lung cancers were identified (70% were stage I). Diagnosis was delayed (false-negative) in 6 patients (stage IIB in 1 patient, stage IIIA in 3 patients, and stage IV in 2 patients), including 2 small cell cancers and 1 central lesion. Surgical biopsy revealed benign disease (false-positives) in 15 cases (14%). Positron emission tomography sensitivity was 88% for prevalent cancers and 70% for cancers diagnosed after first annual screening. No needle biopsy procedures were performed in this cohort of patients. Low-dose computed tomography screening is effective for the early detection of lung cancers, but nodule management remains a challenge. Computed tomography-positron emission tomography is useful at baseline, but its sensitivity decreases significantly the subsequent year. Multidisciplinary management and experience are crucial for minimizing misdiagnoses.

  6. Retinopathy of prematurity screening criteria in Iran: new screening guidelines.

    Science.gov (United States)

    Roohipoor, Ramak; Karkhaneh, Reza; Farahani, Afsar; Ebrahimiadib, Nazanin; Modjtahedi, Bobeck; Fotouhi, Akbar; Yaseri, Mehdi; Khodabande, Alireza; Zarei, Mohammad; Imani Fuladi, Marjan; Taheri, Arash; Riazi Esfahani, Mohammad; Loewenstein, John

    2016-07-01

    To test the applicability of existing retinopathy of prematurity (ROP) guidelines on Iranian patients and to develop novel ROP screening criteria in Iran. Both eyes of 1932 infants born ≤37 weeks of gestation and/or weighting ≤3000 g were included in this prospective cohort study that was conducted across nine neonatal intensive care units and a tertiary eye hospital ROP clinic. The patients were examined for ROP and the need for treatment (type 1 ROP or worse). All the patients were screened 4 weeks after birth or at 31 weeks of postmenstrual age, whichever was later. The patients were followed until retinal vascularisation was completed or the patients reached 50 weeks of gestational age (GA) without prethreshold ROP. A receiver operating characteristic curve was used to determine the best screening criteria for ROP. Screening criteria from other countries were applied to our patient data to determine their ability to appropriately detect ROP. Patients with ROP requiring treatment. The mean GA±SD and birth weight (BW)±SD of the screened patients were 32±2.7 weeks and 1713±516 g, respectively. Using criteria of GA≤32 weeks or BW ≤2000 yielded sensitivity and specificity of 100% and 26.7%, respectively, for treatment requiring ROP regardless of clinical comorbidities. Using screening recommendations of American Academy of Pediatrics would miss 25.4% of ROP and 8.4%ROP requiring treatment in our cohort. Other countries screening recommendations would result in a significant amount of missed cases of treatment requiring ROP when applied to Iran. As a result, we have proposed new guidelines for premature babies in Iran. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  7. Shifts in sensory neuron identity parallel differences in pheromone preference in the European corn borer

    Directory of Open Access Journals (Sweden)

    Fotini A Koutroumpa

    2014-10-01

    Full Text Available Pheromone communication relies on highly specific signals sent and received between members of the same species. However, how pheromone specificity is determined in moth olfactory circuits remains unknown. Here we provide the first glimpse into the mechanism that generates this specificity in Ostrinia nubilalis. In Ostrinia nubilalis it was found that a single locus causes strain-specific, diametrically opposed preferences for a 2-component pheromone blend. Previously we found pheromone preference to be correlated with the strain and hybrid-specific relative antennal response to both pheromone components. This led to the current study, in which we detail the underlying mechanism of this differential response, through chemotopically mapping of the pheromone detection circuit in the antenna. We determined that both strains and their hybrids have swapped the neuronal identity of the pheromone-sensitive neurons co-housed within a single sensillum. Furthermore, neurons that mediate behavioral antagonism surprisingly co-express up to five pheromone receptors, mirroring the concordantly broad tuning to heterospecific pheromones. This appears as possible evolutionary adaptation that could prevent cross attraction to a range of heterospecific signals, while keeping the pheromone detection system to its simplest tripartite setup.

  8. Digital breast tomosynthesis (3D-mammography) screening: A pictorial review of screen-detected cancers and false recalls attributed to tomosynthesis in prospective screening trials.

    Science.gov (United States)

    Houssami, Nehmat; Lång, Kristina; Bernardi, Daniela; Tagliafico, Alberto; Zackrisson, Sophia; Skaane, Per

    2016-04-01

    This pictorial review highlights cancers detected only at tomosynthesis screening and screens falsely recalled in the course of breast tomosynthesis screening, illustrating both true-positive (TP) and false-positive (FP) detection attributed to tomosynthesis. Images and descriptive data were used to characterise cases of screen-detection with tomosynthesis, sourced from prospective screening trials that performed standard (2D) digital mammography (DM) and tomosynthesis (3D-mammography) in the same screening participants. Exemplar cases from four trials highlight common themes of relevance to screening practice including: the type of lesions frequently made more conspicuous or perceptible by tomosynthesis (spiculated masses, and architectural distortions); the histologic findings (both TP and FP) of tomosynthesis-only detection; and the need to extend breast work-up protocols (additional imaging including ultrasound and MRI, and tomosynthesis-guided biopsy) if tomosynthesis is adopted for primary screening. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Single photon transport by a moving atom through sub-wavelength hole

    International Nuclear Information System (INIS)

    Afanasiev, A.E.; Melentiev, P.N.; Kuzin, A.A.; Kalatskiy, A.Yu.; Balykin, V.I.

    2017-01-01

    The results of investigation of photon transport through the subwavelength hole in the opaque screen by using single neutral atom are represented. The basis of the proposed and implemented method is the absorption of a photon by a neutral atom immediately before the subwavelength aperture, traveling of the atoms through the hole and emission of a photon on the other side of the screen. Realized method is the alternative approach to existing for photon transport through a subwavelength aperture: 1) self-sustained transmittance of a photon through the aperture according to the Bethe’s model; 2) extra ordinary transmission because of surface-plasmon excitation.

  10. Metal screen retention for thoron daughter free atoms and atoms attached to condensation nuclei

    International Nuclear Information System (INIS)

    Cash, W.; Webb, J.; Fitts, D.; Skrable, K.W.; Chabot, G.E.

    1978-01-01

    Metal support screens available in a 47 mm commercial filter holder (model F3052-4, available from Scientific Products, Bedford, MA) assembly were tested for retention of thoron daughter atoms and atoms attached to condensation nuclei as a function of the flow rate of the carrier air stream. Sources of Pb-212 were generated on the surface of a metal disk by exposing the disk to thoron emanation generated from a special preparation of Th-228. This source of Pb-212, in transient equilibrium with its daughters, was placed in a flow through chamber connected in series to two of the metal screens backed by a glass fiber filter. Most of the recoil product radioactivity emitted from the Pb-212 source and collected on the screens was due to single atoms of Tl-208, which is born by alpha decay of Bi-212 with a recoil energy of 116 keV. Some free atoms of Bi-212 were also observed. Alpha autoradiographs of Filter samples placed on the downstream side of the two metal screens gave proof of the existence of Pb-212 aggregates through their alpha star images. These aggregate recoil particles were found to have a much higher penetration through the screens than free atoms of Tl-208 and Bi-212. Penetration of Tl-208 atoms and ions decreased exponentially as the inverse of the carrier air flow rate. Penetration varied from 0.047 at 0.088 cfm to 0.661 at 2.47 cfm. Atoms of Pb-212 attached to condensation nuclei were obtained by passing thoron into a reaction chamber containing naturally occurring condensation nuclei from the laboratory. The retention for these attached species varied both as a function of the flow rate and the age of the aerosol. The maximum retention varied from 0.525% at 6.38 cfm to 3.5% at 0.636 cfm for respective delay times of 120 and 30 minutes post the introduction of the thoron into the reaction chamber. A system consisting of a single screen backed by a glass fiber filter may be used to obtain the numbers of radon or thoron daughter free atoms and attached

  11. Biological Evaluations of an Off-Stream Channel, Horizontal Flat-Plate Fish Screen-The Farmers Screen

    Science.gov (United States)

    Mesa, Matthew G.; Rose, Brien P.; Copeland, Elizabeth S.

    2010-01-01

    Screens are commonly installed at water diversion sites to reduce entrainment of fish. Recently, the Farmers Irrigation District in Hood River, Oregon, developed a new flat-plate screen design that offers passive operation and may result in reduced operation and installation costs to irrigators. To evaluate the performance (its biological effect on fish) of this type of screen, two size classes of juvenile coho salmon (Oncorhynchus kistuch) were released over a small version of this screen in the field-the Herman Creek screen. The performance of the screen was evaluated over a range of inflow [0.02 to 0.42 m3/s (cubic meters per second)] and diversion flows (0.02 to 0.34 m3/s) at different weir wall heights. The mean approach velocities for the screen ranged from 0 to 5 cm/s (centimeters per second) and mean sweeping velocities ranged from 36 to 178 cm/s. Water depths over the screen surface ranged from 1 to 25 centimeters and were directly related to weir wall height and inflow. Passage of juvenile coho salmon over the screen under a variety of hydraulic conditions did not severely injure them or cause delayed mortality. For all fish, the mean percentage of body surface area that was injured after passage over the screen ranged from about 0.4 to 3.0%. This occurred even though many fish contacted the screen surface during passage. No fish were observed becoming impinged on the screen surface (greater than 1 second contact with the screen). When operated within its design criteria (diversion flows of about 0.28 m3/s), the screen provided safe and effective downstream passage of juvenile salmonids under a variety of hydraulic conditions. However, we do not recommend operating the screen at inflows less than 0.14 m3/s (5 ft3/s) because water depth can get quite shallow and the screen can completely dewater, particularly at very low flows.

  12. A Screen Space GPGPU Surface LIC Algorithm for Distributed Memory Data Parallel Sort Last Rendering Infrastructures

    Energy Technology Data Exchange (ETDEWEB)

    Loring, Burlen; Karimabadi, Homa; Rortershteyn, Vadim

    2014-07-01

    The surface line integral convolution(LIC) visualization technique produces dense visualization of vector fields on arbitrary surfaces. We present a screen space surface LIC algorithm for use in distributed memory data parallel sort last rendering infrastructures. The motivations for our work are to support analysis of datasets that are too large to fit in the main memory of a single computer and compatibility with prevalent parallel scientific visualization tools such as ParaView and VisIt. By working in screen space using OpenGL we can leverage the computational power of GPUs when they are available and run without them when they are not. We address efficiency and performance issues that arise from the transformation of data from physical to screen space by selecting an alternate screen space domain decomposition. We analyze the algorithm's scaling behavior with and without GPUs on two high performance computing systems using data from turbulent plasma simulations.

  13. Screening for Glaucoma

    Science.gov (United States)

    Understanding Task Force Recommendations Screening for Glaucoma The U.S. Preventive Services Task Force (Task Force) has issued a final recommendation statement on Screening for Glaucoma . This final recommendation statement ...

  14. Socio-demographic characteristics of participation in the opportunistic German cervical cancer screening programme: results from the EPIC-Heidelberg cohort.

    Science.gov (United States)

    Seidel, David; Becker, Nikolaus; Rohrmann, Sabine; Nimptsch, Katharina; Linseisen, Jakob

    2009-04-01

    To analyse participation in the German cervical cancer screening programme by socio-demographic characteristics. In the EPIC-Heidelberg cohort study 13,612 women aged 35-65 years were recruited between 1994 and 1998. Follow-up questionnaires were used to analyse participation in cervical cancer screening. Subjects were categorised according to age (birth cohort), education, vocational training, employment status, marital status and household size. Associations between socio-demographic characteristics and participation in cervical cancer screening were analysed using multinomial logistic regression. Females of the oldest and middle birth cohort were less likely to be screened compared to the youngest birth cohort. Less-educated women and those with a low-level secondary school degree had a decreased likelihood of undergoing screening in comparison to better educated women. Married women and women living in households with four or more persons were more likely to participate in the screening programme than single women or women living alone. Employment status did not modify participation in cervical cancer screening. Knowledge on the characteristics of women with a lower attendance to cervical cancer screening could be used to improve the effectiveness of the current (opportunistic) programme by dedicated health promotion programmes. However, an organized screening programme with written invitation of all eligible women would be the preferred option.

  15. Expanded Newborn Screening Program in Saudi Arabia: Incidence of screened disorders.

    Science.gov (United States)

    Alfadhel, Majid; Al Othaim, Ali; Al Saif, Saif; Al Mutairi, Fuad; Alsayed, Moeenaldeen; Rahbeeni, Zuhair; Alzaidan, Hamad; Alowain, Mohammed; Al-Hassnan, Zuhair; Saeedi, Mohamad; Aljohery, Saeed; Alasmari, Ali; Faqeih, Eissa; Alwakeel, Mansour; AlMashary, Maher; Almohameed, Sulaiman; Alzahrani, Mohammed; Migdad, Abeer; Al-Dirbashi, Osama Y; Rashed, Mohamed; Alamoudi, Mohamed; Jacob, Minnie; Alahaidib, Lujane; El-Badaoui, Fahd; Saadallah, Amal; Alsulaiman, Ayman; Eyaid, Wafaa; Al-Odaib, Ali

    2017-06-01

    To address the implementation of the National Newborn Screening Program (NBS) in Saudi Arabia and stratify the incidence of the screened disorders. A retrospective study conducted between 1 August 2005 and 31 December 2012, total of 775 000 newborns were screened from 139 hospitals distributed among all regions of Saudi Arabia. The NBS Program screens for 16 disorders from a selective list of inborn errors of metabolism (IEM) and endocrine disorders. Heel prick dry blood spot samples were obtained from all newborns for biochemical and immunoassay testing. Recall screening testing was performed for Initial positive results and confirmed by specific biochemical assays. A total of 743 cases were identified giving an overall incidence of 1:1043. Frequently detected disorders nationwide were congenital hypothyroidism and congenital adrenal hyperplasia with an incidence of 1:7175 and 1:7908 correspondingly. The highest incidence among the IEM was propionic acidaemia with an incidence rate of 1:14 000. The article highlights the experience of the NBS Program in Saudi Arabia and providing data on specific regional incidences of all the screened disorders included in the programme; and showed that the incidence of these disorders is one of the highest reported so far world-wide. © 2017 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).

  16. Breast cancer screening

    International Nuclear Information System (INIS)

    Vandenbroucke, A.

    1987-01-01

    Many studies have shown that breast cancer screening is able to reduce breast cancer mortality, including the HIP study, the Swedish Trial and the Netherlands studies. Mammography is considered as the most effective method for breast cancer screening but it might be unfeasible for some reasons: - the population acceptability of the method might be low. Indeed, most populations of the South of Europe are less compliant to mass screening than populations of the North of Europe; - the medical equipment and personnel - radiologists and pathologists - might be insufficient; - it might be too costly for the National Health Service, specially where the incidence rate of breast cancer is relatively low (i.e. Greece, Portugal). The validity of screening tests is judged by their sensitivity and their specificity

  17. Opportunistic detection of glaucomatous optic discs within a diabetic retinopathy screening service.

    Science.gov (United States)

    Treacy, Maxwell P; O'Neill, Evelyn C; Murphy, Melissa; O'Toole, Louise; Delaney, Yvonne; O'Brien, Colm; Connell, Paul P

    2016-06-10

    To determine the prevalence of glaucoma among patients referred to a glaucoma service with suspicious disc photographs from the diabetic retinopathy (DR) screening program. A clinical audit of all patients attending a single-center DR screening program in the Mater Misericordiae University Hospital, Dublin, between July 2010 and October 2011 was conducted with a minimum follow-up of 30 months. The DR screening service uses trained technician graders to assess 2-field color retinal photographs for the features of DR. Recently, the service was enhanced so that optic discs are also assessed for signs of glaucoma. In the 16-month study period, 3,697 diabetic patients were photographed. Following photograph grading, 91 (2.46%) were judged to require referral for assessment at the glaucoma clinic. Of these, 63 (69.23%) presented for assessment. Thirteen patients (20.63%) were diagnosed with glaucoma, comprising 7 cases of low-tension glaucoma and 6 cases of primary open-angle glaucoma. Thirty-six patients (57.14%) were classified as glaucoma suspects and 14 patients (22.22%) were discharged back to the DR screening program following normal ocular examination. Only 6 (9.52%) of the 63 patients examined had an intraocular pressure greater than 21 mm Hg. The assessment of DR screening photographs for signs of glaucomatous optic nerve damage should be considered as part of a strategy to improve glaucoma case detection and to reduce the burden of this disease on society.

  18. A SINGLE-COLUMN PROCEDURE ON BOND ELUT CERTIFY FOR SYSTEMATIC TOXICOLOGICAL ANALYSIS OF DRUGS IN PLASMA AND URINE

    NARCIS (Netherlands)

    CHEN, XH; WIJSBEEK, J; FRANKE, JP; DEZEEUW, RA

    A single-column solid-phase extraction procedure was developed for the screening of acidic, neutral, and basic drugs from plasma. The recoveries of all 25 tested drugs exceeded 82%. After the plasma had been diluted with phosphate buffer (pH 6.0), the drugs were extracted using a single Bond Elut

  19. Does digital mammography in a decentralized breast cancer screening program lead to screening performance parameters comparable with film-screen mammography?

    International Nuclear Information System (INIS)

    Ongeval, Chantal van; Steen, Andre van; Zanca, Federica; Bosmans, Hilde; Marchal, Guy; Putte, Gretel vande; Limbergen, Erik van

    2010-01-01

    To evaluate if the screening performance parameters of digital mammography (DM) in a decentralized screening organization were comparable with film-screen mammography (FSM). A nationwide screening program was launched in 2001, and since 2005 screening with DM has been allowed. Firstly, the parameters of the three regional screening units (RSUs) that first switched to DM (11,355 women) were compared with the FSM period of the same three RSUs (23,325 women). Secondly, they were compared with the results of the whole central breast unit (CBU). The recall rate (RR) of the DM group in the initial round was 2.64% [2.40% for FSM (p = 0.43)] and in the subsequent round 1.20% [1.58% for FSM (p = 0.03)]. The cancer detection rate (CDR) was 0.59% for DM and 0.64% for FSM (p = 0.56). The percentage of ductal carcinoma in situ was 0.07% for DM and 0.16% for FSM (p = 0.02). The positive predictive value was high in the subsequent rounds (DM 48.00%, FSM 45.93%) and lower in the initial round (DM 24.05%, FSM 24.86%). Compared with the results of the whole CBU, DM showed no significant difference. DM can be introduced in a decentralized screening organization with a high CDR without increasing the RR. (orig.)

  20. A Decision Aid to Promote Appropriate Colorectal Cancer Screening among Older Adults: A Randomized Controlled Trial.

    Science.gov (United States)

    Lewis, Carmen L; Kistler, Christine E; Dalton, Alexandra F; Morris, Carolyn; Ferrari, Renée; Barclay, Colleen; Brewer, Noel T; Dolor, Rowena; Harris, Russell; Vu, Maihan; Golin, Carol E

    2018-07-01

    Concerns have been raised about both over- and underutilization of colorectal cancer (CRC) screening in older patients and the need to align screening behavior with likelihood of net benefit. The purpose of this study was to test a novel use of a patient decision aid (PtDA) to promote appropriate CRC screening in older adults. A total of 424 patients ages 70 to 84 y who were not up to date with CRC screening participated in a double-blinded randomized controlled trial of a PtDA targeted to older adults making decisions about whether to undergo CRC screening from March 2012 to February 2015. Patients were randomized to a targeted PtDA or an attention control. The PtDA was designed to facilitate individualized decision making-helping patients understand the potential risks, benefits, and uncertainties of CRC screening given advanced age, health state, preferences, and values. Two composite outcomes, appropriate CRC screening behavior 6 mo after the index visit and appropriate screening intent immediately after the visit, were defined as completed screening or intent for patients in good health, discussion about screening with their provider for patients in intermediate health, and no screening or intent for patients in poor health. Health state was determined by age and Charlson Comorbidity Index. Four hundred twelve (97%) and 421 (99%) patients were analyzed for the primary and secondary outcomes, respectively. Appropriate screening behavior at 6 mo was higher in the intervention group (55% v. 45%, P = 0.023) as was appropriate screening intent following the provider visit (61% v. 47%, P = 0.003). The study took place in a single geographic region. The appropriate CRC screening classification system used in this study has not been formally validated. A PtDA for older adults promoted appropriate CRC screening behavior and intent. Clinicaltrials.gov, registration number NCT01575990. https://clinicaltrials.gov/ct2/show/NCT01575990?term=epic-d&rank=1.

  1. A retrospective audit of the first screening round of the Maltese breast screening programme

    International Nuclear Information System (INIS)

    Mizzi, D.; Zarb, F.; Dennis, A.

    2017-01-01

    Purpose: To analyse whether the screening performance parameters of the Maltese National Breast Screening Programme first screening round met requirements set by European standards. The association between screening age and results of screening performance parameters was also investigated. Method: Quantitative methodology was used to review examinations of women who were recalled for a technical recall or further assessment rates. All accessible members of the population recalled during the first round were retrospectively reviewed resulting in a sample of 2300 recalled examinations. Results: Malta's first screening round met the European Guidelines recommendations for technical repeat rate (0.26%), early recall rate (0.45%), breast cancer detection rate (13.77 per 1000 women) and Positive Predictive Value of screening test (7.58%). However, local recall rate (18.53%) and further assessment rate (18.27%) were higher than recommended. The Chi square test showed a statistically significant difference (p ≤ 0.05) in recall rates between the compared age groups, as younger women (51–55 years) were more likely to have a negative diagnosis after the initial mammogram whereas older women (56–60 years) were more likely to be recalled. There was no age discrepancy (p ≥ 0.05) in local breast cancer detection rate and positive predictive value of screening test. Conclusion: Although the Maltese first screening round performed well, this study found deficiencies in recall and further assessment rates, which according to literature may result in psychological morbidity and inefficient use of screening resources. This study also concluded that when a cohort is analysed, age is not as significant as the screening round itself (first/subsequent). - Highlights: • The Maltese technical and early recall rates complied with European guidelines. • Breast cancer detection rate and positive predictive value conformed to guidelines. • The recall and further

  2. Subcutaneous ICD screening with the Boston Scientific ZOOM programmer versus a 12-lead ECG machine.

    Science.gov (United States)

    Chang, Shu C; Patton, Kristen K; Robinson, Melissa R; Poole, Jeanne E; Prutkin, Jordan M

    2018-02-24

    The subcutaneous implantable cardioverter-defibrillator (S-ICD) requires preimplant screening to ensure appropriate sensing and reduce risk of inappropriate shocks. Screening can be performed using either an ICD programmer or a 12-lead electrocardiogram (ECG) machine. It is unclear whether differences in signal filtering and digital sampling change the screening success rate. Subjects were recruited if they had a transvenous single-lead ICD without pacing requirements or were candidates for a new ICD. Screening was performed using both a Boston Scientific ZOOM programmer (Marlborough, MA, USA) and General Electric MAC 5000 ECG machine (Fairfield, CT, USA). A pass was defined as having at least one lead that fit within the screening template in both supine and sitting positions. A total of 69 subjects were included and 27 sets of ECG leads had differing screening results between the two machines (7%). Of these sets, 22 (81%) passed using the ECG machine but failed using the programmer and five (19%) passed using the ECG machine but failed using the programmer (P machine but failed using the programmer. No subject passed screening with the programmer but failed with the ECG machine. There can be occasional disagreement in S-ICD patient screening between an ICD programmer and ECG machine, all of whom passed with the ECG machine but failed using the programmer. On a per lead basis, the ECG machine passes more subjects. It is unknown what the inappropriate shock rate would be if an S-ICD was implanted. Clinical judgment should be used in borderline cases. © 2018 Wiley Periodicals, Inc.

  3. Screening for skin cancer.

    Science.gov (United States)

    Helfand, M; Mahon, S M; Eden, K B; Frame, P S; Orleans, C T

    2001-04-01

    Malignant melanoma is often lethal, and its incidence in the United States has increased rapidly over the past 2 decades. Nonmelanoma skin cancer is seldom lethal, but, if advanced, can cause severe disfigurement and morbidity. Early detection and treatment of melanoma might reduce mortality, while early detection and treatment of nonmelanoma skin cancer might prevent major disfigurement and to a lesser extent prevent mortality. Current recommendations from professional societies regarding screening for skin cancer vary. To examine published data on the effectiveness of routine screening for skin cancer by a primary care provider, as part of an assessment for the U.S. Preventive Services Task Force. We searched the MEDLINE database for papers published between 1994 and June 1999, using search terms for screening, physical examination, morbidity, and skin neoplasms. For information on accuracy of screening tests, we used the search terms sensitivity and specificity. We identified the most important studies from before 1994 from the Guide to Clinical Preventive Services, second edition, and from high-quality reviews. We used reference lists and expert recommendations to locate additional articles. Two reviewers independently reviewed a subset of 500 abstracts. Once consistency was established, the remainder were reviewed by one reviewer. We included studies if they contained data on yield of screening, screening tests, risk factors, risk assessment, effectiveness of early detection, or cost effectiveness. We abstracted the following descriptive information from full-text published studies of screening and recorded it in an electronic database: type of screening study, study design, setting, population, patient recruitment, screening test description, examiner, advertising targeted at high-risk groups or not targeted, reported risk factors of participants, and procedure for referrals. We also abstracted the yield of screening data including probabilities and numbers

  4. Mechanical polishing as an improved surface treatment for platinum screen-printed electrodes

    Directory of Open Access Journals (Sweden)

    Junqiao Lee

    2016-07-01

    Full Text Available The viability of mechanical polishing as a surface pre-treatment method for commercially available platinum screen-printed electrodes (SPEs was investigated and compared to a range of other pre-treatment methods (UV-Ozone treatment, soaking in N,N-dimethylformamide, soaking and anodizing in aqueous NaOH solution, and ultrasonication in tetrahydrofuran. Conventional electrochemical activation of platinum SPEs in 0.5 M H2SO4 solution was ineffective for the removal of contaminants found to be passivating the screen-printed surfaces. However, mechanical polishing showed a significant improvement in hydrogen adsorption and in electrochemically active surface areas (probed by two different redox couples due to the effective removal of surface contaminants. Results are also presented that suggest that SPEs are highly susceptible to degradation by strong acidic or caustic solutions, and could potentially lead to instability in long-term applications due to continual etching of the binding materials. The ability of SPEs to be polished effectively extends the reusability of these traditionally “single-use” devices. Keywords: Screen-printed electrodes, Polishing, Platinum, Activation, Pre-treatment, Cyclic voltammetry

  5. Between Stage and Screen

    NARCIS (Netherlands)

    Tornqvist, Egil

    1996-01-01

    Ingmar Bergman is worldwide known as a film and stage director. Yet no-one has attempted to compare his stage and screen activities. In Between stage and screen Egil Tornqvist examines formal and thematical correspondences and differences between a number of Bergman's stage, screen, and radio

  6. In-bead screening

    DEFF Research Database (Denmark)

    2013-01-01

    The present invention relates to screening of one-bead-one-compound (OBOC) combinatorial libraries which is useful for the discovery of compounds displaying molecular interactions with a biological or a physicochemical system, such as substrates and inhibitors of enzymes and the like. The invention...... provides a method for screening a library of compounds for their interaction with a physico- chemical or biological system and a corresponding kit for performing the method of screening a one-bead-one-compound library of compounds....

  7. siMacro: A Fast and Easy Data Processing Tool for Cell-Based Genomewide siRNA Screens

    Directory of Open Access Journals (Sweden)

    Nitin Kumar Singh

    2013-03-01

    Full Text Available Growing numbers of studies employ cell line-based systematic short interfering RNA (siRNA screens to study gene functions and to identify drug targets. As multiple sources of variations that are unique to siRNA screens exist, there is a growing demand for a computational tool that generates normalized values and standardized scores. However, only a few tools have been available so far with limited usability. Here, we present siMacro, a fast and easy-to-use Microsoft Office Excel-based tool with a graphic user interface, designed to process single-condition or two-condition synthetic screen datasets. siMacro normalizes position and batch effects, censors outlier samples, and calculates Z-scores and robust Z-scores, with a spreadsheet output of >120,000 samples in under 1 minute.

  8. Screening for Posttraumatic Stress Disorder among Somali ex-combatants: A validation study

    Directory of Open Access Journals (Sweden)

    Rockstroh Brigitte

    2007-09-01

    Full Text Available Abstract Background In Somalia, a large number of active and former combatants are affected by psychological problems such as Posttraumatic Stress Disorder (PTSD. This disorder impairs their ability to re-integrate into civilian life. However, many screening instruments for Posttraumatic Stress Disorder used in post-conflict settings have limited validity. Here we report on development and validation of a screening tool for PTSD in Somali language with a sample of ex-combatants. Methods We adapted the Posttraumatic Diagnostic Scale (PDS to reflect linguistic and cultural differences within the Somali community so that local interviewers could be trained to administer the scale. For validation purposes, a randomly selected group of 135 Somali ex-combatants was screened by trained local interviewers; 64 of them were then re-assessed by trained clinical psychologists using the Composite International Diagnostic Interview (CIDI and the Self-Report Questionnaire (SRQ-20. Results The screening instrument showed good internal consistency (Cronbach's α = .86, convergent validity with the CIDI (sensitivity = .90; specificity = .90 as well as concurrent validity: positive cases showed higher SRQ-20 scores, higher prevalence of psychotic symptoms, and higher levels of intake of the local stimulant drug khat. Compared to a single cut-off score, the multi-criteria scoring, in keeping with the DSM-IV, produced more diagnostic specificity. Conclusion The results provide evidence that our screening instrument is a reliable and valid method to detect PTSD among Somali ex-combatants. A future Disarmament, Demobilization and Reintegration Program in Somalia is recommended to screen for PTSD in order to identify ex-combatants with special psycho-social needs.

  9. Psychosocial consequences in the Danish randomised controlled lung cancer screening trial (DLCST).

    Science.gov (United States)

    Rasmussen, Jakob F; Siersma, V; Pedersen, J H; Brodersen, J

    2015-01-01

    To measure the psychosocial consequences in the Danish lung cancer screening trial (DLCST) and compare those between the computed tomography (CT) group and the control group. This study was a single centre randomised controlled trial with five annual screening rounds. Healthy current or former heavy smokers aged 50-70 years (men and women) were randomised 1:1 to a CT group and a control group. Heavy smokers were defined by having smoked ≥20 pack years and former smokers by being abstinent ≤10 years. Both groups were invited annually to the screening clinic to complete the validated lung-cancer-specific questionnaire consequences of screening lung cancer (COS-LC). The CT group was also offered a low dose CT scan of the lungs. The COS-LC measures nine scales with psychosocial properties: Anxiety, Behaviour, Dejection, Negative impact on sleep, Self-blame, Focus on Airway Symptoms, Stigmatisation, Introvert, and Harm of Smoking. 4104 participants were randomised to the DLCST and the COS-LC completion rates for the CT group and the control group were 95.5% and 73.6%, respectively. There was a significant increase in negative psychosocial consequences from baseline through rounds 2-5 for both the CT group and the control group (mean increase >0, p0 and p<.033). Lung cancer CT-screening trials induced more negative psychosocial reactions in both the CT group and the control group compared with the baseline psychosocial profile. The CT group experienced less negative psychosocial consequences compared with the control group, which might be explained by reassurance among those with normal screening results. ClinicalTrials.gov: NCT00496977. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  10. Band structure engineering in van der Waals heterostructures via dielectric screening: the GΔW method

    DEFF Research Database (Denmark)

    Winther, Kirsten Trøstrup; Thygesen, Kristian Sommer

    2017-01-01

    precise magnitude is non-trivial to predict because of the non-local nature of the screening in quasi-2D crystals. Moreover, the effect is not captured by effective single-particle methods such as density functional theory. Here we present an efficient and general method for calculating the band gap...

  11. Development of Single Cell Raman Spectroscopy for Cancer Screening and Therapy Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Chan, James W. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2009-02-24

    The overall goal of this project was to develop a new technology for cancer detection based on single cell laser tweezers Raman spectroscopy (LTRS). This method has the potential to improve the detection of cancer characteristics in single cells by acquiring cellular spectral markers that reflect the intrinsic biology of the cell. These spectral biomarkers are a new form of molecular signatures in the field of cancer research that may hold promise in accurately identifying and diagnosing cancer and measuring patient response to treatment. The primary objectives of this proposed work were to perform a full characterization of the Raman spectra of single normal, transformed, and cancer cells to identify cancer spectral signatures, validate the clinical significance of these results by direct correlation to established clinical parameters for assessing cancer, and to develop the optical technology needed for efficient sampling and analysis of cells needed for the practical use of such a system in the clinic. The results indicated that normal T and B lymphocytes could be distinguished from their neoplastic cultured cells and leukemia patient cells with classification sensitivities and specificities routinely exceeding 90% based on multivariate statistical analysis and leave-one-out cross validation. Differences primarily in the Raman peaks associated with DNA and protein were observed between normal and leukemic cells and were consistent for both the cultured and primary cells. Differences between normal and leukemia patient cells were more subtle than between normal and leukemia cultured cells but were still significant to allow for accurate discrimination. Furthermore, it is revealed that the spectral differences are representative of the neoplastic phenotype of the cells and not a reflection of the different metabolic states (resting versus active) of normal and leukemic cells. The effect of different standard cell fixation protocols (i.e. methanol, paraformaledhye

  12. Mammography for women in their 40s : to screen or not to screen

    International Nuclear Information System (INIS)

    Le Heron, J.

    1997-01-01

    In the United States there is currently a raging controversy as to whether women in their 40s should be screened for breast cancer, with responsible medical bodies each issuing divergent recommendations. With the imminent commencement of the national breast screening programme in New Zealand, it is relevant to briefly review what underlies these differences. The evicence from international studies is that breast cancer deaths on the population of women aged 50 to 69 can be reduced by about 30% by good mammography screening programes. However the evidence in not so unequivocal for the 40 to 49 age group. Breast cancer in younger women tends to be more virulent, growing faster, and killing faster, and detection of cancer in younger breasts is more difficult than in breasts of older women due to the presence of greater amounts of glandular tissue. Where does this leave breast screening in New Zealand? The nationwide breast screening programme will commence with asymmptomatic women aged 50-64 eligible for screening. Extension to women older than 64 will be considered again once the programme is in place and running well. The Ministry of Health has not recommended routine screening for women in their 40s, but will continue to monitor the latest information and if, sufficient new evidence becomes availabe, the screening guidelines will be reassessed. (author)

  13. Just-in-Time Compound Pooling Increases Primary Screening Capacity without Compromising Screening Quality.

    Science.gov (United States)

    Elkin, L L; Harden, D G; Saldanha, S; Ferguson, H; Cheney, D L; Pieniazek, S N; Maloney, D P; Zewinski, J; O'Connell, J; Banks, M

    2015-06-01

    Compound pooling, or multiplexing more than one compound per well during primary high-throughput screening (HTS), is a controversial approach with a long history of limited success. Many issues with this approach likely arise from long-term storage of library plates containing complex mixtures of compounds at high concentrations. Due to the historical difficulties with using multiplexed library plates, primary HTS often uses a one-compound-one-well approach. However, as compound collections grow, innovative strategies are required to increase the capacity of primary screening campaigns. Toward this goal, we have developed a novel compound pooling method that increases screening capacity without compromising data quality. This method circumvents issues related to the long-term storage of complex compound mixtures by using acoustic dispensing to enable "just-in-time" compound pooling directly in the assay well immediately prior to assay. Using this method, we can pool two compounds per well, effectively doubling the capacity of a primary screen. Here, we present data from pilot studies using just-in-time pooling, as well as data from a large >2-million-compound screen using this approach. These data suggest that, for many targets, this method can be used to vastly increase screening capacity without significant reduction in the ability to detect screening hits. © 2015 Society for Laboratory Automation and Screening.

  14. Characteristics and screening outcome of women referred twice at screening mammography

    International Nuclear Information System (INIS)

    Setz-Pels, Wikke; Duijm, Lucien E.M.; Jansen, Frits H.; Louwman, Marieke W.J.; Roumen, Rudi M.H.; Voogd, Adri C.

    2012-01-01

    To determine the characteristics and screening outcome of women referred twice at screening mammography. We included 424,703 consecutive screening mammograms and collected imaging, biopsy and surgery reports of women with screen-detected breast cancer. Review of screening mammograms was performed to determine whether or not an initial and second referral comprised the same lesion. The overall positive predictive value of referral for cancer was 38.6% (95% CI 37.3-39.8%). Of 147 (2.6%) women referred twice, 86 had been referred for a different lesion at second referral and 32 of these proved malignant (37.2%, 95% CI 27.0-47.4%). Sixty-one women had been referred twice for the same lesion, of which 22 proved malignant (36.1%, 95% CI 24.1-48.0%). Characteristics of these women were comparable to women with cancer diagnosed after first referral. Compared with women without cancer at second referral for the same lesion, women with cancer more frequently showed suspicious densities at screening mammography (86.4% vs 53.8%, P = 0.02) and work-up at first referral had less frequently included biopsy (22.7% vs 61.5%, P = 0.004). Cancer risk in women referred twice for the same lesion is similar to that observed in women referred once, or referred for a second time but for a different lesion. (orig.)

  15. Cervical Cancer Screening

    Science.gov (United States)

    ... Cancer found early may be easier to treat. Cervical cancer screening is usually part of a woman's health ... may do more tests, such as a biopsy. Cervical cancer screening has risks. The results can sometimes be ...

  16. High-throughput screening of hybridoma supernatants using multiplexed fluorescent cell barcoding on live cells.

    Science.gov (United States)

    Lu, Mei; Chan, Brian M; Schow, Peter W; Chang, Wesley S; King, Chadwick T

    2017-12-01

    With current available assay formats using either immobilized protein (ELISA, enzyme-linked immunosorbent assay) or immunostaining of fixed cells for primary monoclonal antibody (mAb) screening, researchers often fail to identify and characterize antibodies that recognize the native conformation of cell-surface antigens. Therefore, screening using live cells has become an integral and important step contributing to the successful identification of therapeutic antibody candidates. Thus the need for developing high-throughput screening (HTS) technologies using live cells has become a major priority for therapeutic mAb discovery and development. We have developed a novel technique called Multiplexed Fluorescent Cell Barcoding (MFCB), a flow cytometry-based method based upon the Fluorescent Cell Barcoding (FCB) technique and the Luminex fluorescent bead array system, but is applicable to high-through mAb screens on live cells. Using this technique in our system, we can simultaneously identify or characterize the antibody-antigen binding of up to nine unique fluorescent labeled cell populations in the time that it would normally take to process a single population. This has significantly reduced the amount of time needed for the identification of potential lead candidates. This new technology enables investigators to conduct large-scale primary hybridoma screens using flow cytometry. This in turn has allowed us to screen antibodies more efficiently than before and streamline identification and characterization of lead molecules. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Screening sensitivity theory

    International Nuclear Information System (INIS)

    Oblow, E.M.; Perey, F.G.

    1984-01-01

    A comprehensive rigorous theory is developed for screening sensitivity coefficients in largescale modeling applications. The theory uses Bayesian inference and group theory to establish a probabilistic framework for solving an underdetermined system of linear equations. The underdetermined problem is directly related to statistical screening sensitivity theory as developed in recent years. Several examples of the new approach to screening are worked out in detail and comparisons are made with statistical approaches to the problem. The drawbacks of these latter methods are discussed at some length

  18. Field effect of screened charges: electrical detection of peptides and proteins by a thin-film resistor.

    Science.gov (United States)

    Lud, Simon Q; Nikolaides, Michael G; Haase, Ilka; Fischer, Markus; Bausch, Andreas R

    2006-02-13

    For many biotechnological applications the label-free detection of biomolecular interactions is becoming of outstanding importance. In this Article we report the direct electrical detection of small peptides and proteins by their intrinsic charges using a biofunctionalized thin-film resistor. The label-free selective and quantitative detection of small peptides and proteins is achieved using hydrophobized silicon-on-insulator (SOI) substrates functionalized with lipid membranes that incorporate metal-chelating lipids. The response of the nanometer-thin conducting silicon film to electrolyte screening effects is taken into account to determine quantitatively the charges of peptides. It is even possible to detect peptides with a single charge and to distinguish single charge variations of the analytes even in physiological electrolyte solutions. As the device is based on standard semiconductor technologies, parallelization and miniaturization of the SOI-based biosensor is achievable by standard CMOS technologies and thus a promising basis for high-throughput screening or biotechnological applications.

  19. Fragment-based screening in tandem with phenotypic screening provides novel antiparasitic hits.

    Science.gov (United States)

    Blaazer, Antoni R; Orrling, Kristina M; Shanmugham, Anitha; Jansen, Chimed; Maes, Louis; Edink, Ewald; Sterk, Geert Jan; Siderius, Marco; England, Paul; Bailey, David; de Esch, Iwan J P; Leurs, Rob

    2015-01-01

    Methods to discover biologically active small molecules include target-based and phenotypic screening approaches. One of the main difficulties in drug discovery is elucidating and exploiting the relationship between drug activity at the protein target and disease modification, a phenotypic endpoint. Fragment-based drug discovery is a target-based approach that typically involves the screening of a relatively small number of fragment-like (molecular weight <300) molecules that efficiently cover chemical space. Here, we report a fragment screening on TbrPDEB1, an essential cyclic nucleotide phosphodiesterase (PDE) from Trypanosoma brucei, and human PDE4D, an off-target, in a workflow in which fragment hits and a series of close analogs are subsequently screened for antiparasitic activity in a phenotypic panel. The phenotypic panel contained T. brucei, Trypanosoma cruzi, Leishmania infantum, and Plasmodium falciparum, the causative agents of human African trypanosomiasis (sleeping sickness), Chagas disease, leishmaniasis, and malaria, respectively, as well as MRC-5 human lung cells. This hybrid screening workflow has resulted in the discovery of various benzhydryl ethers with antiprotozoal activity and low toxicity, representing interesting starting points for further antiparasitic optimization. © 2014 Society for Laboratory Automation and Screening.

  20. Single tube genotyping of sickle cell anaemia using PCR-based SNP analysis.

    Science.gov (United States)

    Waterfall, C M; Cobb, B D

    2001-12-01

    Allele-specific amplification (ASA) is a generally applicable technique for the detection of known single nucleotide polymorphisms (SNPs), deletions, insertions and other sequence variations. Conventionally, two reactions are required to determine the zygosity of DNA in a two-allele system, along with significant upstream optimisation to define the specific test conditions. Here, we combine single tube bi-directional ASA with a 'matrix-based' optimisation strategy, speeding up the whole process in a reduced reaction set. We use sickle cell anaemia as our model SNP system, a genetic disease that is currently screened using ASA methods. Discriminatory conditions were rapidly optimised enabling the unambiguous identification of DNA from homozygous sickle cell patients (HbS/S), heterozygous carriers (HbA/S) or normal DNA in a single tube. Simple downstream mathematical analyses based on product yield across the optimisation set allow an insight into the important aspects of priming competition and component interactions in this competitive PCR. This strategy can be applied to any polymorphism, defining specific conditions using a multifactorial approach. The inherent simplicity and low cost of this PCR-based method validates bi-directional ASA as an effective tool in future clinical screening and pharmacogenomic research where more expensive fluorescence-based approaches may not be desirable.

  1. A reliable computational workflow for the selection of optimal screening libraries.

    Science.gov (United States)

    Gilad, Yocheved; Nadassy, Katalin; Senderowitz, Hanoch

    2015-01-01

    The experimental screening of compound collections is a common starting point in many drug discovery projects. Successes of such screening campaigns critically depend on the quality of the screened library. Many libraries are currently available from different vendors yet the selection of the optimal screening library for a specific project is challenging. We have devised a novel workflow for the rational selection of project-specific screening libraries. The workflow accepts as input a set of virtual candidate libraries and applies the following steps to each library: (1) data curation; (2) assessment of ADME/T profile; (3) assessment of the number of promiscuous binders/frequent HTS hitters; (4) assessment of internal diversity; (5) assessment of similarity to known active compound(s) (optional); (6) assessment of similarity to in-house or otherwise accessible compound collections (optional). For ADME/T profiling, Lipinski's and Veber's rule-based filters were implemented and a new blood brain barrier permeation model was developed and validated (85 and 74 % success rate for training set and test set, respectively). Diversity and similarity descriptors which demonstrated best performances in terms of their ability to select either diverse or focused sets of compounds from three databases (Drug Bank, CMC and CHEMBL) were identified and used for diversity and similarity assessments. The workflow was used to analyze nine common screening libraries available from six vendors. The results of this analysis are reported for each library providing an assessment of its quality. Furthermore, a consensus approach was developed to combine the results of these analyses into a single score for selecting the optimal library under different scenarios. We have devised and tested a new workflow for the rational selection of screening libraries under different scenarios. The current workflow was implemented using the Pipeline Pilot software yet due to the usage of generic

  2. Effects of repeated mammographic screening on breast cancer stage distribution

    International Nuclear Information System (INIS)

    Fagerberg, G.; Baldetorp, L.; Groentoft, O.; Lundstroem, B.; Maanson, J.C.; Nordenskjoeld, B.

    1985-01-01

    A randomised controlled trial of mass screening for breast cancer by single-view mammography was begun in Sweden in 1977. All women aged 40 and older and resident in the counties of Koppaberg and Oestergoetland were enrolled. The present report is confined to the Oestergoetland study, which started in 1978 and comprised 92934 women. After randomisation, which was done on the basis of communities rather than individuals, 47001 women were allocated to the study group and offered repeated mammographic screening; 45933 were allocated to the control group. As compliance among women over 74 years of age was poor these were excluded from the present report. The yearly incidence of stage II or more advanced breast cancers after the initial screening round up to and including the second was reduced by 40 per cent in the study group compared with the controls. This effect was less marked in the age group 40-49. After 5.5 years average from the date of entry the absolute number of women with stage II-IV disease in the control group exceeded that for the study group by 44, whereas there was a large excess of cancer in situ and stage I cancer in the study group. (orig.)

  3. Hierarchical screening for multiple mental disorders.

    Science.gov (United States)

    Batterham, Philip J; Calear, Alison L; Sunderland, Matthew; Carragher, Natacha; Christensen, Helen; Mackinnon, Andrew J

    2013-10-01

    There is a need for brief, accurate screening when assessing multiple mental disorders. Two-stage hierarchical screening, consisting of brief pre-screening followed by a battery of disorder-specific scales for those who meet diagnostic criteria, may increase the efficiency of screening without sacrificing precision. This study tested whether more efficient screening could be gained using two-stage hierarchical screening than by administering multiple separate tests. Two Australian adult samples (N=1990) with high rates of psychopathology were recruited using Facebook advertising to examine four methods of hierarchical screening for four mental disorders: major depressive disorder, generalised anxiety disorder, panic disorder and social phobia. Using K6 scores to determine whether full screening was required did not increase screening efficiency. However, pre-screening based on two decision tree approaches or item gating led to considerable reductions in the mean number of items presented per disorder screened, with estimated item reductions of up to 54%. The sensitivity of these hierarchical methods approached 100% relative to the full screening battery. Further testing of the hierarchical screening approach based on clinical criteria and in other samples is warranted. The results demonstrate that a two-phase hierarchical approach to screening multiple mental disorders leads to considerable increases efficiency gains without reducing accuracy. Screening programs should take advantage of prescreeners based on gating items or decision trees to reduce the burden on respondents. © 2013 Elsevier B.V. All rights reserved.

  4. Virtual colonoscopy: a new alternative for colorectal neoplasm screening?; Colonoscopia virtual: una nueva alternativa en el screening del cancer colorrectal?

    Energy Technology Data Exchange (ETDEWEB)

    Carrascosa, P; Castiglioni, R; Sanchez, F; Capunay, C; Mazzuco, J; Carrascosa, J [Diagnostico Maipu, Vicente Lopez, Buenos Aires (Argentina)

    2000-07-01

    The authors presents 46 patients-series with virtual colonoscopy. The findings obtained through virtual colonoscopy were divided into 7 groups: 1) Single polypoid lesion (9 patients); 2) Associated polypoid lesions (11 patients); 3) Tumoral stenosis without synchronic lesion (3 patients); 4) Tumoral stenosis with synchronic lesion (6 patients); 5) Non-tumoral stenosis (4 patients); 6) Normal studies (2 patients); 7) Patients excluded due to wrong preparation (11 patients). We concluded that the virtual colonoscopy is a valid alternative in the screening of the colorectal pathology, showing some advantages when compared to the usual studies, since it is non-invasive, does not require sedation, and allows the staging of the neoplasm. (author)

  5. Single borehole test sensitivity towards crack and rock parameter. Lesson Hortberg; Einbohrlochtracertestsensitivitaet gegenueber Riss und Gesteinsparametern. Lektion Horstberg

    Energy Technology Data Exchange (ETDEWEB)

    Ghergut, Iulia; Behrens, Horst; Sauter, Martin [Goettingen Univ. (Germany). Angewandte Geologie

    2012-10-16

    The novel experiments of the GeoZentrum Hanover (Hanover, Federal Republic of Germany) on geothermal energy at the well bore Horstberg in the south heath also motivated the accompanying tracertest-mindset to move away from the tracer job stereotypes. For some possible designs at the tracertest at this drilling (forced-gradient divergent push by water fracking of Detfurth perforation, single-screen push-pull at Solling perforation, single-screen push-pull at Detfurth perforation, and so forth) the analysis shows how and why the controlling parameter do not comply with the mental basic pattern of the expectations at the tracertests ('tracertest by crack {yields} characterization of the crack', 'tracer residence time {yields} prognosis of the thermal lifetime').

  6. 20 CFR 654.408 - Screening.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Screening. 654.408 Section 654.408 Employees... EMPLOYMENT SERVICE SYSTEM Housing for Agricultural Workers Housing Standards § 654.408 Screening. (a) All outside openings shall be protected with screening of not less than 16 mesh. (b) All screen doors shall be...

  7. Moving beyond Screen Time: Redefining Developmentally Appropriate Technology Use in Early Childhood Education. Policy Brief

    Science.gov (United States)

    Daugherty, Lindsay; Dossani, Rafiq; Johnson, Erin-Elizabeth; Wright, Cameron

    2014-01-01

    Conversations about what constitutes "developmentally appropriate" use of technology in early childhood education have, to date, focused largely on a single, blunt measure--screen time--that fails to capture important nuances, such as what type of media a child is accessing and whether technology use is taking place solo or with peers.…

  8. Management of urinary tract infections in pregnancy: a review with comments on single dose therapy.

    Science.gov (United States)

    Zinner, S H

    1992-01-01

    Most investigators agree that the adverse effects of urinary tract infections in pregnancy can be abrogated by effective early detection and treatment. However, the optimal methods for screening and treatment remain controversial. Although single-dose therapy has not been applied to pregnant women with acute pyelonephritis, most but not all studies which have compared single-dose with longer courses of beta-lactam or other antibiotics in pregnant asymptomatic bacteriuric women have shown no differences in outcome. This paper reviews recent trials of single-dose treatment of bacteriuria in pregnant women.

  9. Influence of a screening navigation program on social inequalities in health beliefs about colorectal cancer screening.

    Science.gov (United States)

    Vallet, Fanny; Guillaume, Elodie; Dejardin, Olivier; Guittet, Lydia; Bouvier, Véronique; Mignon, Astrid; Berchi, Célia; Salinas, Agnès; Launoy, Guy; Christophe, Véronique

    2016-08-01

    The aim of the study was to test whether a screening navigation program leads to more favorable health beliefs and decreases social inequalities in them. The selected 261 noncompliant participants in a screening navigation versus a usual screening program arm had to respond to health belief measures inspired by the Protection Motivation Theory. Regression analyses showed that social inequalities in perceived efficacy of screening, favorable attitude, and perceived facility were reduced in the screening navigation compared to the usual screening program. These results highlight the importance of health beliefs to understand the mechanism of screening navigation programs in reducing social inequalities. © The Author(s) 2014.

  10. piggyBac transposon somatic mutagenesis with an activated reporter and tracker (PB-SMART for genetic screens in mice.

    Directory of Open Access Journals (Sweden)

    Sean F Landrette

    Full Text Available Somatic forward genetic screens have the power to interrogate thousands of genes in a single animal. Retroviral and transposon mutagenesis systems in mice have been designed and deployed in somatic tissues for surveying hematopoietic and solid tumor formation. In the context of cancer, the ability to visually mark mutant cells would present tremendous advantages for identifying tumor formation, monitoring tumor growth over time, and tracking tumor infiltrations and metastases into wild-type tissues. Furthermore, locating mutant clones is a prerequisite for screening and analyzing most other somatic phenotypes. For this purpose, we developed a system using the piggyBac (PB transposon for somatic mutagenesis with an activated reporter and tracker, called PB-SMART. The PB-SMART mouse genetic screening system can simultaneously induce somatic mutations and mark mutated cells using bioluminescence or fluorescence. The marking of mutant cells enable analyses that are not possible with current somatic mutagenesis systems, such as tracking cell proliferation and tumor growth, detecting tumor cell infiltrations, and reporting tissue mutagenesis levels by a simple ex vivo visual readout. We demonstrate that PB-SMART is highly mutagenic, capable of tumor induction with low copy transposons, which facilitates the mapping and identification of causative insertions. We further integrated a conditional transposase with the PB-SMART system, permitting tissue-specific mutagenesis with a single cross to any available Cre line. Targeting the germline, the system could also be used to conduct F1 screens. With these features, PB-SMART provides an integrated platform for individual investigators to harness the power of somatic mutagenesis and phenotypic screens to decipher the genetic basis of mammalian biology and disease.

  11. [Breast cancer screening in Austria: Key figures, age limits, screening intervals and evidence].

    Science.gov (United States)

    Jeitler, Klaus; Semlitsch, Thomas; Posch, Nicole; Siebenhofer, Andrea; Horvath, Karl

    2015-01-01

    In January 2014, the first nationwide quality-assured breast cancer screening program addressing women aged ≥ 40 years was introduced in Austria. As part of the process of developing a patient information leaflet, the Evidence Based Medicine (EBM) Review Center of the Medical University of Graz was charged with the task of assessing the potential benefits and harms of breast cancer screening from the available evidence. Based on these results, key figures were derived for mortality, false-positive and false-negative mammography results, and overdiagnosis, considering Austria-specific incidence rates for breast cancer and breast cancer mortality. Furthermore, the current evidence regarding age limits and screening interval, which were the subjects of controversial public discussions, was analyzed. A systematic search for primary and secondary literature was performed and additional evidence was screened, e. g., evaluation reports of European breast cancer screening programs. On the basis of the available evidence and of the Austrian breast cancer mortality and incidence rates, it can be assumed that - depending on the age group - 1 to 4 breast cancer deaths can be avoided per 1,000 women screened in a structured breast cancer screening program, while the overall mortality remains unchanged. On the other hand, 150 to 200 of these 1,000 women will be affected by false-positive results and 1 to 9 women by overdiagnosis due to the structured breast cancer screening. Therefore, the overall benefit-harm balance is uncertain. If women from 40 to 44 or above 70 years of age are considered, who can also participate in the Austrian screening program, even a negative benefit-harm balance seems possible. However, with the implementation of quality standards in breast cancer screening and the dissemination of a patient information leaflet, an improvement in the medical treatment situation, specifically in terms of informed decision-making, can be expected. Copyright © 2015

  12. Physician and Nurse Acceptance of Technicians to Screen for Geriatric Syndromes in the Emergency Department

    Directory of Open Access Journals (Sweden)

    Brian F Gage

    2011-05-01

    Full Text Available Introduction: The objective of this study was to evaluate emergency medicine physician and nurse acceptance of nonnurse, nonphysician screening for geriatric syndromes. Methods: This was a single-center emergency department (ED survey of physicians and nurses after an 8-month project. Geriatric technicians were paid medical student research assistants evaluating consenting ED patients older than 65 years for cognitive dysfunction, fall risk, or functional decline. The primary objective of this anonymous survey was to evaluate ED nurse and physician perceptions about the geriatric screener feasibility and barriers to implementation. In addition, as a secondary objective, respondents reported ongoing geriatric screening efforts independent of the research screeners. Results: The survey was completed by 72% of physicians and 33% of nurses. Most nurses and physicians identified geriatric technicians as beneficial to patients without impeding ED throughput. Fewer than 25% of physicians routinely screen for any geriatric syndromes. Nurses evaluated for fall risk significantly more often than physicians, but no other significant differences were noted in ongoing screening efforts. Conclusion: Dedicated geriatric technicians are perceived by nurses and physicians as beneficial to patients with the potential to improve patient safety and clinical outcomes. Most nurses and physicians are not currently screening for any geriatric syndromes. [West J Emerg Med. 2011;12(4:489–495.

  13. Radiation accident dosimetry: TL properties of mobile phone screen glass

    International Nuclear Information System (INIS)

    Bassinet, C.; Pirault, N.; Baumann, M.; Clairand, I.

    2014-01-01

    Mobile phones are carried by a large part of the population and previous studies have shown that they may be able to function as individual fortuitous dosimeters in case of radiological accident. This study deals with thermoluminescence (TL) properties of mobile phone screen glass. The presence of a significant background signal which partially overlaps with the radiation-induced signal is a serious issue for dose reconstruction. A mechanical method to reduce this signal using a diamond grinding bit is presented. An over-response at low energy (∼50 keV) is observed for two investigated glasses. The results of a dose recovery test using a single-aliquot regenerative-dose (SAR) procedure are discussed. - Highlights: • Mobile phone screen glass is a promising material for retrospective dosimetry. • The TL non-radiation induced background signal can be significantly reduced by a mechanical method. • A dose recovery test using an SAR procedure was successfully carried out for the investigated glass

  14. Phonon-limited mobility in n-type single-layer MoS2 from first principles

    DEFF Research Database (Denmark)

    Kaasbjerg, Kristen; Thygesen, Kristian S.; Jacobsen, Karsten W.

    2012-01-01

    We study the phonon-limited mobility in intrinsic n-type single-layer MoS2 for temperatures T > 100 K. The materials properties including the electron-phonon interaction are calculated from first principles and the deformation potentials and Frohlich interaction in single-layer MoS2 are established...... to recent experimental findings for the mobility in single-layer MoS2 (similar to 200 cm(2)V(-1)s(-1)), our results indicate that mobilities close to the intrinsic phonon-limited mobility can be achieved in two-dimensional materials via dielectric engineering that effectively screens static Coulomb...

  15. Depression screening among older adults attending low-vision rehabilitation and eye-care services: Characteristics of those who screen positive and client acceptability of screening.

    Science.gov (United States)

    Holloway, Edith E; Sturrock, Bonnie A; Lamoureux, Ecosse L; Keeffe, Jill E; Rees, Gwyneth

    2015-12-01

    To investigate characteristics associated with screening positive for depressive symptoms among older adults accessing low-vision rehabilitation and eye-care services and to determine client acceptability of depression screening using the Patient Health Questionnaire-2 (PHQ-2) in these settings. One-hundred and twenty-four older adults (mean = 77.02 years, SD = 9.12) attending low-vision rehabilitation and eye-care services across Australia were screened for depression and invited to complete a telephone-administered questionnaire to determine characteristics associated with depressive symptoms and client acceptability of screening in these settings. Thirty-seven per cent (n = 46/124) of participants screened positive for depressive symptoms, and the majority considered the new depression screening method to be a 'good idea' in vision services (85%). Severe vision loss (<6/60 in the better eye) was associated with an increased odds of screening positive for depressive symptoms (odds ratio 2.37; 95% confidence interval 1.08-6.70) even after adjusting for potential confounders. Participants who screened positive had a preference for 'talking' therapy or a combination of medication and 'talking therapy' delivered within their own home (73%) or via telephone (67%). The PHQ-2 appears to be an acceptable method for depression screening in eye-care settings among older adults. Targeted interventions that incorporate home-based or telephone delivered therapy sessions may improve outcomes for depression in this group. © 2014 ACOTA.

  16. Cost-effectiveness of screening and correcting refractive errors in school children in Africa, Asia, America and Europe.

    Science.gov (United States)

    Baltussen, Rob; Naus, Jeroen; Limburg, Hans

    2009-02-01

    To estimate the costs and effects of alternative strategies for annual screening of school children for refractive errors, and the provision of spectacles, in different WHO sub-regions in Africa, Asia, America and Europe. We developed a mathematical simulation model for uncorrected refractive error, using prevailing prevalence and incidence rates. Remission rates reflected the absence or presence of screening strategies for school children. All screening strategies were implemented for a period of 10 years and were compared to a situation were no screening was implemented. Outcome measures were life years adjusted for disability (DALYs), costs of screening and provision of spectacles and follow-up for six different screening strategies, and cost-effectiveness in international dollars per DALY averted. Epidemiological information was derived from the burden of disease study from the World Health Organization (WHO). Cost data were derived from large databases from the WHO. Both univariate and multivariate sensitivity analyses were performed on key parameters to determine the robustness of the model results. In all regions, screening of 5-15 years old children yields most health effects, followed by screening of 11-15 years old, 5-10 years old, and screening of 8 and 13 years old. Screening of broad-age intervals is always more costly than screening of single-age intervals, and there are important economies of scale for simultaneous screening of both 5-10 and 11-15-year-old children. In all regions, screening of 11-15 years old is the most cost-effective intervention, with the cost per DALY averted ranging from I$67 per DALY averted in the Asian sub-region to I$458 per DALY averted in the European sub-region. The incremental cost per DALY averted of screening 5-15 years old ranges between I$111 in the Asian sub-region to I$672 in the European sub-region. Considering the conservative study assumptions and the robustness of study conclusions towards changes in these

  17. [Overdiagnosis in cancer screening].

    Science.gov (United States)

    Cervera Deval, J; Sentís Crivillé, M; Zulueta, J J

    2015-01-01

    In screening programs, overdiagnosis is defined as the detection of a disease that would have gone undetected without screening when that disease would not have resulted in morbimortality and was treated unnecessarily. Overdiagnosis is a bias inherent in screening and an undesired effect of secondary prevention and improved sensitivity of diagnostic techniques. It is difficult to discriminate a priori between clinically relevant diagnoses and those in which treatment is unnecessary. To minimize the effects of overdiagnosis, screening should be done in patients at risk. Copyright © 2014 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  18. Screening for colorectal cancer

    DEFF Research Database (Denmark)

    Nielsen, Hans J.; Jakobsen, Karen V.; Christensen, Ib J.

    2011-01-01

    Emerging results indicate that screening improves survival of patients with colorectal cancer. Therefore, screening programs are already implemented or are being considered for implementation in Asia, Europe and North America. At present, a great variety of screening methods are available including...... into improvements of screening for colorectal cancer includes blood-based biological markers, such as proteins, DNA and RNA in combination with various demographically and clinically parameters into a "risk assessment evaluation" (RAE) test. It is assumed that such a test may lead to higher acceptance among...... procedures for colorectal cancer. Therefore, results of present research, validating RAE tests, are awaited with interest....

  19. Substance Abuse Screening

    Science.gov (United States)

    ... information is collected, stored or sent over the Internet. To ensure complete privacy, exit your web browser after completing this screening. ... information is collected, stored or sent over the Internet. To ensure complete privacy, exit your web browser after completing this screening. ...

  20. [Construction and screening of phage antibody libraries against epidermal growth factor receptor and soluble expression of single chain Fv].

    Science.gov (United States)

    Sheng, Wei-Jin; Miao, Qing-Fang; Zhen, Yong-Su

    2009-06-01

    Recent studies have shown that epidermal growth factor receptor (EGFR) is an important target for cancer therapy. The present study prepared single chain Fv (scFv) directed against EGFR. Balb/c mice were immunized by human carcinoma A431 cells, and total RNA of the splenic cells was extracted. VH and VL gene fragments were amplified by RT-PCR and further joined into scFv gene with a linker, then scFv gene fragments were ligated into the phagemid vector pCANTAB 5E. The phagemid containing scFv were transformed into electro-competent E. coli TG1 cells. The recombinant phage antibody library was constructed through rescuing the transformed cells with help phage M13K07. The specified recombinant phages were enriched through 5 rounds of affinity panning and the anti-EGFR phage scFv clones were screened and identified with ELISA. A total of 48 clones from the library were selected randomly and 45 clones were identified positive. After infecting E. coli HB2151 cells with one positive clone, soluble recombinant antibodies about 27 kD were produced and located in the periplasm and the supernatant. The result of sequencing showed that the scFv gene was 768 bp, which encoded 256 amino acid residues. VH and VL including 3 CDRs and 4 FRs, respectively, were all homologous to mouse Ig. The soluble scFv showed the specific binding activity to purified EGFR and EGFR located in carcinoma cell membrane. The successful preparation of anti-EGFR scFv will provide an EGFR targeted molecule for the development of antibody-based drugs and biological therapy of cancer.

  1. Exploring avenues for best use of cytotechnologists in non-gynaecological cytology: Double screening or independent sign-out.

    Science.gov (United States)

    Fischer, G; Haddad, M; Cormier, K

    2018-02-01

    Cytotechnologist (CT) screening workload has been decreasing due to the falling number of Papanicolaou tests. This continuing trend has prompted exploration of ways to best employ the CT skillset. One potential way of more effective use is by having two CTs double screen non-gynaecological (NGC) cases to assess whether this improves screening quality and concordance with pathologists. Another is evaluating the CT's performance on low-complexity negative NGC cases for a potential independent CT sign-out without pathologist review. In total, 1119 NGC cases were reviewed; 577 screened by two CTs and 542 screened by one CT. All cases were signed out by a pathologist and all CT interpretations were compared to the pathologist final diagnoses. The disagreements were classified based on degree of discrepancy. The extra workload by adding the second screener was assessed. The agreement rate between the CT's screening interpretation and pathologist's interpretation did not improve by adding a second CT compared to a single screener (91.5% vs 92.9%, respectively). CT to pathologist concordance was very high on low complexity NGC cases (voided urine, fluid, sputum) whether screened and interpreted as negative by one CT (97.3%) or two CTs (99.3%). Double screening of NGC cases by two cytotechnologists prior to pathologist sign-out does not improve screening quality and is not cost-effective. The high concordance between the CTs and pathologists in this limited group of low complexity negative cases suggests that such cases could be signed out independently by cytotechnologists. © 2017 John Wiley & Sons Ltd.

  2. Color correction of projected image on color-screen for mobile beam-projector

    Science.gov (United States)

    Son, Chang-Hwan; Sung, Soo-Jin; Ha, Yeong-Ho

    2008-01-01

    With the current trend of digital convergence in mobile phones, mobile manufacturers are researching how to develop a mobile beam-projector to cope with the limitations of a small screen size and to offer a better feeling of movement while watching movies or satellite broadcasting. However, mobile beam-projectors may project an image on arbitrary surfaces, such as a colored wall and paper, not on a white screen mainly used in an office environment. Thus, color correction method for the projected image is proposed to achieve good image quality irrespective of the surface colors. Initially, luminance values of original image transformed into the YCbCr space are changed to compensate for spatially nonuniform luminance distribution of arbitrary surface, depending on the pixel values of surface image captured by mobile camera. Next, the chromaticity values for each surface and white-screen image are calculated using the ratio of the sum of three RGB values to one another. Then their chromaticity ratios are multiplied by converted original image through an inverse YCbCr matrix to reduce an influence of modulating the appearance of projected image due to spatially different reflectance on the surface. By projecting corrected original image on a texture pattern or single color surface, the image quality of projected image can be improved more, as well as that of projected image on white screen.

  3. The efficacy of using CAD for detection of breast cancer in mammography screening A systematic review

    DEFF Research Database (Denmark)

    Henriksen, Emilie; Lauridsen, Carsten Ammitzbøl

    Abstract Purpose: The aim of this systematic review is to present an overview of the available studies concerning the use of computer-aided detection (CAD) systems in screening mammography for early detection of breast cancer and compare the diagnostic accuracy and recall rates of single reading....... The literature search resulted in 1522 records after duplicates were removed. 1491 records were excluded by abstract and 18 were excluded after assessing the eligibility by full text reading. A total of 13 articles were included in this study. Results: The results for the single reading vs. single reading...... with CAD group indicate that the addition of CAD increases sensitivity and cancer detection rate (CDR). For the double reading vs. single reading with CAD group none of the studies reported significant differences in sensitivity and CDR. Adding CAD to single reading increased the recall rates and decreased...

  4. High Throughput Single-cell and Multiple-cell Micro-encapsulation

    OpenAIRE

    Lagus, Todd P.; Edd, Jon F.

    2012-01-01

    Microfluidic encapsulation methods have been previously utilized to capture cells in picoliter-scale aqueous, monodisperse drops, providing confinement from a bulk fluid environment with applications in high throughput screening, cytometry, and mass spectrometry. We describe a method to not only encapsulate single cells, but to repeatedly capture a set number of cells (here we demonstrate one- and two-cell encapsulation) to study both isolation and the interactions between cells in groups of ...

  5. WE-D-207-03: CT Protocols for Screening and the ACR Designated Lung Screening Program

    International Nuclear Information System (INIS)

    McNitt-Gray, M.

    2015-01-01

    In the United States, Lung Cancer is responsible for more cancer deaths than the next four cancers combined. In addition, the 5 year survival rate for lung cancer patients has not improved over the past 40 to 50 years. To combat this deadly disease, in 2002 the National Cancer Institute launched a very large Randomized Control Trial called the National Lung Screening Trial (NLST). This trial would randomize subjects who had substantial risk of lung cancer (due to age and smoking history) into either a Chest X-ray arm or a low dose CT arm. In November 2010, the National Cancer Institute announced that the NLST had demonstrated 20% fewer lung cancer deaths among those who were screened with low-dose CT than with chest X-ray. In December 2013, the US Preventive Services Task Force recommended the use of Lung Cancer Screening using low dose CT and a little over a year later (Feb. 2015), CMS announced that Medicare would also cover Lung Cancer Screening using low dose CT. Thus private and public insurers are required to provide Lung Cancer Screening programs using CT to the appropriate population(s). The purpose of this Symposium is to inform medical physicists and prepare them to support the implementation of Lung Screening programs. This Symposium will focus on the clinical aspects of lung cancer screening, requirements of a screening registry for systematically capturing and tracking screening patients and results (such as required Medicare data elements) as well as the role of the medical physicist in screening programs, including the development of low dose CT screening protocols. Learning Objectives: To understand the clinical basis and clinical components of a lung cancer screening program, including eligibility criteria and other requirements. To understand the data collection requirements, workflow, and informatics infrastructure needed to support the tracking and reporting components of a screening program. To understand the role of the medical physicist in

  6. Magnetorefractive cell on basis of the Salisbury screen

    Energy Technology Data Exchange (ETDEWEB)

    Boriskina, Ju.V. [Faculty of Physics, Moscow State University, Leninski Gory, Moscow 119992 (Russian Federation) and Institute of Theoretical and Applied Electrodynamics, OIVT, RAS, Moscow 125412 (Russian Federation)]. E-mail: j_boriskina@mail.ru; Erokhin, S.G. [Faculty of Physics, Moscow State University, Leninski Gory, Moscow 119992 (Russian Federation); Institute of Theoretical and Applied Electrodynamics, OIVT, RAS, Moscow 125412 (Russian Federation); Vinogradov, A.P. [Institute of Theoretical and Applied Electrodynamics, OIVT, RAS, Moscow 125412 (Russian Federation); Inoue, M. [Toyohashi University of Technology, 1-1, Hibari-Ga-Oka, Tempaku, Toyohashi 441-8580 (Japan); Granovsky, A.B. [Faculty of Physics, Moscow State University, Leninski Gory, Moscow 119992 (Russian Federation)

    2006-05-15

    Recently, it has been shown that the magnetorefractive effect (MRE) can be significantly enhanced if a layer of material exhibiting MRE is placed inside a photonic crystal to form a defect mode. We propose to use for the MRE enhancement the Salisbury screen as a competitive and much more simple scheme. Since MRE is mostly due to a change of light absorption under magnetization the three-layer Salisbury structure optimized for highest possible absorption inside magnetic layer provides MRE at least two orders of magnitude greater than that for single layer and of the same value or even greater than that for 37-layer photonic crystal.

  7. Magnetorefractive cell on basis of the Salisbury screen

    International Nuclear Information System (INIS)

    Boriskina, Ju.V.; Erokhin, S.G.; Vinogradov, A.P.; Inoue, M.; Granovsky, A.B.

    2006-01-01

    Recently, it has been shown that the magnetorefractive effect (MRE) can be significantly enhanced if a layer of material exhibiting MRE is placed inside a photonic crystal to form a defect mode. We propose to use for the MRE enhancement the Salisbury screen as a competitive and much more simple scheme. Since MRE is mostly due to a change of light absorption under magnetization the three-layer Salisbury structure optimized for highest possible absorption inside magnetic layer provides MRE at least two orders of magnitude greater than that for single layer and of the same value or even greater than that for 37-layer photonic crystal

  8. New perspectives on preimplantation genetic diagnosis and preimplantation genetic screening.

    Science.gov (United States)

    Chen, Chun-Kai; Yu, Hsing-Tse; Soong, Yung-Kuei; Lee, Chyi-Long

    2014-06-01

    Preimplantation genetic diagnosis is a procedure that involves the removal of one or more nuclei from oocytes (a polar body) or embryos (blastomeres or trophectoderm cells) in order to test for problems in genome sequence or chromosomes of the embryo prior to implantation. It provides new hope of having unaffected children, as well as avoiding the necessity of terminating an affected pregnancy for genetic parents who carry an affected gene or have balanced chromosomal status. Polymerase chain reaction-based molecular techniques are the methods used to detect gene defects with a known sequence and X-linked diseases. The indication for using this approach has expanded for couples who are prevented from having babies because they carry a serious genetic disorder to couples with conditions that are not immediately life threatening, such as cancer predisposition genes and Huntington disease. In addition, fluorescent in situ hybridization (FISH) has been widely applied for the detection of chromosome abnormalities. FISH allows the evaluation of many chromosomes at the same time, up to 15 chromosome pairs in a single cell. Preimplantation genetic screening, defined as a test that screens for aneuploidy, has been most commonly used in situations of advanced maternal age, a history of recurrent miscarriage, a history of repeated implantation failure, or a severe male factor. Unfortunately, randomized controlled trials have as yet shown no benefit with respect to preimplantation genetic screening using cleavage stage biopsy, which is probably attributable to the high levels of mosaicism at early cleavage stages and the limitations of FISH. Recently, two main types of array-based technology combined with whole genome amplification have been developed for use in preimplantation genetic diagnosis; these are comparative genomic hybridization and single nucleotide polymorphism-based arrays. Both allow the analysis of all chromosomes, and the latter also allows the haplotype of

  9. Screen or not to screen for peripheral arterial disease: guidance from a decision model.

    Science.gov (United States)

    Vaidya, Anil; Joore, Manuela A; Ten Cate-Hoek, Arina J; Ten Cate, Hugo; Severens, Johan L

    2014-01-29

    Asymptomatic Peripheral Arterial Disease (PAD) is associated with greater risk of acute cardiovascular events. This study aims to determine the cost-effectiveness of one time only PAD screening using Ankle Brachial Index (ABI) test and subsequent anti platelet preventive treatment (low dose aspirin or clopidogrel) in individuals at high risk for acute cardiovascular events compared to no screening and no treatment using decision analytic modelling. A probabilistic Markov model was developed to evaluate the life time cost-effectiveness of the strategy of selective PAD screening and consequent preventive treatment compared to no screening and no preventive treatment. The analysis was conducted from the Dutch societal perspective and to address decision uncertainty, probabilistic sensitivity analysis was performed. Results were based on average values of 1000 Monte Carlo simulations and using discount rates of 1.5% and 4% for effects and costs respectively. One way sensitivity analyses were performed to identify the two most influential model parameters affecting model outputs. Then, a two way sensitivity analysis was conducted for combinations of values tested for these two most influential parameters. For the PAD screening strategy, life years and quality adjusted life years gained were 21.79 and 15.66 respectively at a lifetime cost of 26,548 Euros. Compared to no screening and treatment (20.69 life years, 15.58 Quality Adjusted Life Years, 28,052 Euros), these results indicate that PAD screening and treatment is a dominant strategy. The cost effectiveness acceptability curves show 88% probability of PAD screening being cost effective at the Willingness To Pay (WTP) threshold of 40000 Euros. In a scenario analysis using clopidogrel as an alternative anti-platelet drug, PAD screening strategy remained dominant. This decision analysis suggests that targeted ABI screening and consequent secondary prevention of cardiovascular events using low dose aspirin or

  10. Comparison of first-tier cell-free DNA screening for common aneuploidies with conventional publically funded screening.

    Science.gov (United States)

    Langlois, Sylvie; Johnson, JoAnn; Audibert, François; Gekas, Jean; Forest, Jean-Claude; Caron, André; Harrington, Keli; Pastuck, Melanie; Meddour, Hasna; Tétu, Amélie; Little, Julian; Rousseau, François

    2017-12-01

    This study evaluates the impact of offering cell-free DNA (cfDNA) screening as a first-tier test for trisomies 21 and 18. This is a prospective study of pregnant women undergoing conventional prenatal screening who were offered cfDNA screening in the first trimester with clinical outcomes obtained on all pregnancies. A total of 1198 pregnant women were recruited. The detection rate of trisomy 21 with standard screening was 83% with a false positive rate (FPR) of 5.5% compared with 100% detection and 0% FPR for cfDNA screening. The FPR of cfDNA screening for trisomies 18 and 13 was 0.09% for each. Two percent of women underwent an invasive diagnostic procedure based on screening or ultrasound findings; without the cfDNA screening, it could have been as high as 6.8%. Amongst the 640 women with negative cfDNA results and a nuchal translucency (NT) ultrasound, only 3 had an NT greater or equal to 3.5 mm: one had a normal outcome and two lost their pregnancy before 20 weeks. cfDNA screening has the potential to be a highly effective first-tier screening approach leading to a significant reduction of invasive diagnostic procedures. For women with a negative cfDNA screening result, NT measurement has limited clinical utility. © 2017 John Wiley & Sons, Ltd.

  11. Newborn hearing screening.

    Science.gov (United States)

    Stewart, D L; Pearlman, A

    1994-11-01

    Congenital deafness is a relatively common problem with an incidence of 1/300 to 1/1000. Most states have no mass screening program for hearing loss, but the state of Kentucky compiles a High Risk Registry which is a historical survey of parents relating to risk factors for hearing loss. Unfortunately this survey can miss 50% of those who have a hearing deficit. If not detected prior to discharge, there is often a delay in diagnosis of deafness which prevents early intervention. We report 2 years' experience at Kosair Children's Hospital where 1,987 infants admitted to well baby, intermediate, or intensive care nurseries were screened using the ALGO-1 screener (Natus Medical Inc, Foster City, CA) which is a modified auditory brain stem evoked response (ABR). Our screening of this population led to an 11% incidence of referral for complete audiological evaluation. There were no significant complications. Forty-eight infants were found to have nonspecified, sensorineural, or conductive hearing loss. The positive predictive value of the test was 96%. Therefore, we feel that the use of the modified ABR in the newborn is a timely, cost efficient method of screening for hearing loss and should be used for mass screening of all newborns.

  12. High incidence of hypermethioninaemia in a single neonatal intensive care unit detected by a newly introduced neonatal screening programme

    NARCIS (Netherlands)

    ten Hoedt, A. E.; van Kempen, A. A.; Boelen, A.; Duran, M.; Kemper-Proper, E. A.; Oey-Spauwen, M. J. W.; Wijburg, F. A.; Bosch, A. M.

    2007-01-01

    From 1 January 2007 an expanded neonatal screening programme was initiated in the Netherlands, including homocystinuria with methionine as the primary marker. During the first 2 months hypermethioninaemia was detected in 14 newborns who, after proper evaluation, were demonstrated not to have

  13. A novel glutamine–RNA interaction identified by screening libraries in mammalian cells

    OpenAIRE

    Tan, Ruoying; Frankel, Alan D.

    1998-01-01

    The arginine-rich motif provides a versatile framework for RNA recognition in which few amino acids other than arginine are needed to mediate specific binding. Using a mammalian screening system based on transcriptional activation by HIV Tat, we identified novel arginine-rich peptides from combinatorial libraries that bind tightly to the Rev response element of HIV. Remarkably, a single glutamine, but not asparagine, within a stretch of polyarginine can mediate high-affinity binding. These re...

  14. Screening for abdominalt aortaaneurisme

    DEFF Research Database (Denmark)

    Lindholt, Jes Sanddal; Juul, Søren; Henneberg, E W

    1997-01-01

    In spite of increasing number of elective resections of abdominal aortic aneurysms (AAA) the mortality or ruptured AAA is increasing. The advantages of elective operations are obvious; the lethality is 2-6% while the lethality of ruptured AAA is 75-95%. However, AAA seldom causes symptoms before...... rupture. Ultrasonographic screening for AAA takes 10 minutes per scan, and the sensitivity and specificity are high. Ultrasonographic screening for AAA is a reliable, safe and inexpensive method for screening, and screening for AAA is discussed worldwide. One point four percent of deaths among men from 65...... to 80 year of age are caused by ruptured AAA. Screening men over 65 for AAA can theoretically prevent a substantial number of deaths. Our calculations predict one prevented AAA-death per 200-300 scans for a cost of about 4000 DKK per saved year of life. However, cost-benefit analyses are based...

  15. Cost Analysis of Universal Screening vs. Risk Factor-Based Screening for Methicillin-Resistant Staphylococcus aureus (MRSA.

    Directory of Open Access Journals (Sweden)

    Virginia R Roth

    Full Text Available The literature remains conflicted regarding the most effective way to screen for MRSA. This study was designed to assess costs associated with universal versus risk factor-based screening for the reduction of nosocomial MRSA transmission.The study was conducted at The Ottawa Hospital, a large multi-centre tertiary care facility with approximately 47,000 admissions annually. From January 2006-December 2007, patients underwent risk factor-based screening for MRSA on admission. From January 2008 to August 2009 universal MRSA screening was implemented. A comparison of costs incurred during risk factor-based screening and universal screening was conducted. The model incorporated probabilities relating to the likelihood of being tested and the results of polymerase chain reaction (PCR testing with associated effects in terms of MRSA bacteremia and true positive and negative test results. Inputted costs included laboratory testing, contact precautions and infection control, private room costs, housekeeping, and length of hospital stay. Deterministic sensitivity analyses were conducted.The risk factor-based MRSA screening program screened approximately 30% of admitted patients and cost the hospital over $780 000 annually. The universal screening program screened approximately 83% of admitted patients and cost over $1.94 million dollars, representing an excess cost of $1.16 million per year. The estimated additional cost per patient screened was $17.76.This analysis demonstrated that a universal MRSA screening program was costly from a hospital perspective and was previously known to not be clinically effective at reducing MRSA transmission. These results may be useful to inform future model-based economic analyses of MRSA interventions.

  16. Obesity Prevention and Screening.

    Science.gov (United States)

    Mackey, Eleanor R; Olson, Alexandra; DiFazio, Marc; Cassidy, Omni

    2016-03-01

    Obesity is widespread, associated with several physical and psychosocial comorbidities, and is difficult to treat. Prevention of obesity across the lifespan is critical to improving the health of individuals and society. Screening and prevention efforts in primary care are an important step in addressing the obesity epidemic. Each period of human development is associated with unique risks, challenges, and opportunities for prevention and intervention. Screening tools for overweight/obesity, although imperfect, are quick and easy to administer. Screening should be conducted at every primary care visit and tracked longitudinally. Screening tools and cutoffs for overweight and obesity vary by age group. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Mammography screening in Denmark

    DEFF Research Database (Denmark)

    Vejborg, Ilse; Mikkelsen, Ellen Margrethe; Garne, Jens Peter

    2011-01-01

    Mammography screening is offered healthy women, and a high standard on professional and organizational level is mandatory not only in the screening programme but even in the diagnostic work-up and treatment. The main goal is to achieve a substantial reduction in disease specific mortality......, but it is not possible to evaluate the effect on mortality until several years later, and continuously monitoring of the quality of all aspects of a screening programme is necessary. Based on other European guidelines, 11 quality indicators have been defined, and guidelines concerning organizational requirements...... for a Danish screening programme as well as recommendations for the radiographic and radiological work have been drawn up....

  18. Mass screening in breast cancer

    International Nuclear Information System (INIS)

    Strax, P.

    1977-01-01

    Some questions about mass screening in breast cancer are answered it being concluded that: 1. mass screening for the detection of early breast cancer is the only means with proven potential for lowering the death rate of the disease; 2. mammography is an importante - if not the most important modality in mass screening; 3. new film - screen combinations generally available are capable of producing mammograms of excelent quality with radiation doses down to .1 rad into the body of breast. The risk of malignant changes from such dosage - even when given periodically is negligeable. New equipment, to be available, shortly, will use the new film - screen combinations in an automated manner with must reduce cost in time, filme, personnel and processing - of more than 50%. This would make mass screening more practical. (M.A.) [pt

  19. Current Cervical Carcinoma Screening Guidelines

    Directory of Open Access Journals (Sweden)

    Megan J. Schlichte

    2015-05-01

    Full Text Available A formidable threat to the health of women, cervical carcinoma can be prevented in many cases with adequate screening. The current guidelines for cervical carcinoma screening were created as joint recommendations of the American Cancer Society (ACS, the American Society for Colposcopy and Cervical Pathology (ASCCP and the American Society for Clinical Pathology (ASCP in 2012, and later accepted and promoted by the American Congress of Obstetricians and Gynecologists (ACOG. The 2012 recommendations underscore the utility of molecular testing as an adjunct to cytology screening for certain women and provide guidance to clinicians based on different risk-benefit considerations for different ages. This manuscript will review screening techniques and current recommendations for cervical cancer screening and human papilloma virus (HPV testing, as well as possible future screening strategies.

  20. [Comparison of screening performance between primary high-risk HPV screening and high-risk HPV screening plus liquid-based cytology cotesting in diagnosis of cervical precancerous or cancerous lesions].

    Science.gov (United States)

    Zhao, X L; Remila, Rezhake; Hu, S Y; Zhang, L; Xu, X Q; Chen, F; Pan, Q J; Zhang, X; Zhao, F H

    2018-05-06

    Objective: To evaluate and compare the screening performance of primary high-risk HPV(HR-HPV) screening and HR-HPV screening plus liquid-based cytology (LBC) cotesting in diagnosis of cervical cancer and precancerous lesions (CIN2+). Methods: We pooled 17 population-based cross-sectional studies which were conducted across China from 1999 to 2008. After obtaining informed consent, all women received liquid-based cytology(LBC)testing, HR-HPV DNA testing. Totally 28 777 women with complete LBC, HPV and biopsy results were included in the final analysis. Screening performance of primary HR-HPV DNA screening and HPV screening plus LBC co-testing in diagnosis of CIN2+ were calculated and compared among different age groups. Results: Among the whole population, the detection rates of primary HR-HPV screening and HR-HPV screening plus LBC co-testing are 3.05% (879 CIN2+) and 3.13%(900 CIN2+), respectively. The sensitivity were 96.4% and 98.7% (χ(2)=19.00, PHPV screening performed better than co-testing (AUC were 0.913 and 0.888; Z= 6.16, PHPV screening, co-testing showed significantly higher colposcopy referral rates (16.5% and 23.6%, respectively, χ(2)=132.00, PHPV screening in diagnosis of CIN2+, and was 12.5 (15.7%(288 cases) vs 1.3%(23 cases)) times as much as the detection rate of HR-HPV screening plus cytology contesting. Conclusion: Compared with primary HR-HPV screening, HR-HPV screening plus cytology co-testing does not show better results in the screening performance for CIN2+ detection, and the cost-effectiveness is not good enough, especially in younger age group.

  1. Clinically targeted screening for congenital CMV - potential for integration into the National Hearing Screening Programme.

    Science.gov (United States)

    Kadambari, S; Luck, S; Davis, A; Williams, Ej; Berrington, J; Griffiths, Pd; Sharland, M

    2013-10-01

    Screening for a condition should only be undertaken if certain strict criteria are met. Congenital CMV (cCMV) is a leading cause of sensorineuronal hearing loss (SNHL) and meets many of these criteria, but is not currently screened for in the UK. Ganciclovir reduces CMV-induced progressive SNHL if treatment is begun in the first month of life. The Newborn Hearing Screening Programme (NHSP) has been shown to identify SNHL at the earliest possible age. The potential of integrating screening for cCMV into the NHSP is discussed to consolidate the link between screening, early diagnosis and management. The early diagnosis and treatment of cCMV may prevent a small proportion of late SNHL. In the absence of any screening programme, we provide evidence that clinically targeted screening through the NHSP is a potential option in the UK, enhancing the diagnostic pathway and enabling appropriate early treatment to reduce long-term morbidity. ©2013 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  2. Empirical study of supervised gene screening

    Directory of Open Access Journals (Sweden)

    Ma Shuangge

    2006-12-01

    Full Text Available Abstract Background Microarray studies provide a way of linking variations of phenotypes with their genetic causations. Constructing predictive models using high dimensional microarray measurements usually consists of three steps: (1 unsupervised gene screening; (2 supervised gene screening; and (3 statistical model building. Supervised gene screening based on marginal gene ranking is commonly used to reduce the number of genes in the model building. Various simple statistics, such as t-statistic or signal to noise ratio, have been used to rank genes in the supervised screening. Despite of its extensive usage, statistical study of supervised gene screening remains scarce. Our study is partly motivated by the differences in gene discovery results caused by using different supervised gene screening methods. Results We investigate concordance and reproducibility of supervised gene screening based on eight commonly used marginal statistics. Concordance is assessed by the relative fractions of overlaps between top ranked genes screened using different marginal statistics. We propose a Bootstrap Reproducibility Index, which measures reproducibility of individual genes under the supervised screening. Empirical studies are based on four public microarray data. We consider the cases where the top 20%, 40% and 60% genes are screened. Conclusion From a gene discovery point of view, the effect of supervised gene screening based on different marginal statistics cannot be ignored. Empirical studies show that (1 genes passed different supervised screenings may be considerably different; (2 concordance may vary, depending on the underlying data structure and percentage of selected genes; (3 evaluated with the Bootstrap Reproducibility Index, genes passed supervised screenings are only moderately reproducible; and (4 concordance cannot be improved by supervised screening based on reproducibility.

  3. Effects of screened Coulomb (Yukawa) and exponential-cosine-screened Coulomb potentials on photoionization of H and He+

    International Nuclear Information System (INIS)

    Lin, C.Y.; Ho, Y.K.

    2010-01-01

    The screening effects due to the exponential-cosine-screened Coulomb and screened Coulomb (Yukawa) potentials on photoionization processes are explored within the framework of complex coordinate rotation method. The energy levels of H and He + in both screened potentials shifted with various Debye screening lengths are presented. The photoionization cross sections illustrate the considerable screening effects on photoionization processes in low energy region. The shape resonances can be found near ionization thresholds for certain of Debye screening lengths. The relations between the appearance of resonances and the existence of quasi-bound states under shielding conditions are discussed. (authors)

  4. A Screening Tool for Assessing Alcohol Use Risk among Medically Vulnerable Youth.

    Directory of Open Access Journals (Sweden)

    Sharon Levy

    Full Text Available In an effort to reduce barriers to screening for alcohol use in pediatric primary care, the National Institute on Alcoholism and Alcohol Abuse (NIAAA developed a two-question Youth Alcohol Screening Tool derived from population-based survey data. It is unknown whether this screening tool, designed for use with general populations, accurately identifies risk among youth with chronic medical conditions (YCMC. This growing population, which comprises nearly one in four youth in the US, faces a unique constellation of drinking-related risks.To validate the NIAAA Youth Alcohol Screening Tool in a population of YCMC, we performed a cross-sectional validation study with a sample of 388 youth ages 9-18 years presenting for routine subspecialty care at a large children's hospital for type 1 diabetes, persistent asthma, cystic fibrosis, inflammatory bowel disease, or juvenile idiopathic arthritis. Participants self-administered the NIAAA Youth Alcohol Screening Tool and the Diagnostic Interview Schedule for Children as a criterion standard measure of alcohol use disorders (AUD. Receiver operating curve analysis was used to determine cut points for identifying youth at moderate and highest risk for an AUD.Nearly one third of participants (n = 118; 30.4% reported alcohol use in the past year; 86.4% (106 of past year drinkers did not endorse any AUD criteria, 6.8% (n = 8 of drinkers endorsed a single criterion, and 6.8% of drinkers met criteria for an AUD. Using the NIAAA tool, optimal cut points found to identify youth at moderate and highest risk for an AUD were ≥ 6 and ≥12 drinking days in the past year, respectively.The NIAAA Youth Alcohol Screening Tool is highly efficient for detecting alcohol use and discriminating disordered use among YCMC. This brief screen appears feasible for use in specialty care to ascertain alcohol-related risk that may impact adversely on health status and disease management.

  5. Descriptive epidemiology of screen and non-screen sedentary time in adolescents: a cross sectional study

    Directory of Open Access Journals (Sweden)

    Ridley Kate

    2010-12-01

    Full Text Available Abstract Background Much attention has been paid to adolescents' screen time, however very few studies have examined non-screen sedentary time (NSST. This study aimed to (1 describe the magnitude and composition of screen sedentary time (SST and NSST in Australian adolescents, (2 describe the socio-demographic correlates of SST and NSST, and (3 determine whether screen time is an adequate surrogate for total sedentary behaviour in this population. Methods 2200 9-16 year old Australians provided detailed use of time data for four days. Non-screen sedentary time (NSST included time spent participating in activities expected to elicit Results Adolescents spent a mean (SD of 345 (105 minutes/day in NSST, which constituted 60% of total sedentary time. School activities contributed 42% of NSST, socialising 19%, self-care (mainly eating 16%, and passive transport 15%. Screen time and NSST showed opposite patterns in relation to key socio-demographic characteristics, including sex, age, weight status, household income, parental education and day type. Because screen time was negatively correlated with NSST (r = -0.58, and exhibited a moderate correlation (r = 0.53 with total sedentary time, screen time was only a moderately effective surrogate for total sedentary time. Conclusions To capture a complete picture of young people's sedentary time, studies should endeavour to measure both screen time and NSST.

  6. Positive predictive values by mammographic density and screening mode in the Norwegian Breast Cancer Screening Program.

    Science.gov (United States)

    Moshina, Nataliia; Ursin, Giske; Roman, Marta; Sebuødegård, Sofie; Hofvind, Solveig

    2016-01-01

    To investigate the probability of breast cancer among women recalled due to abnormal findings on the screening mammograms (PPV-1) and among women who underwent an invasive procedure (PPV-2) by mammographic density (MD), screening mode and age. We used information about 28,826 recall examinations from 26,951 subsequently screened women in the Norwegian Breast Cancer Screening Program, 1996-2010. The radiologists who performed the recall examinations subjectively classified MD on the mammograms into three categories: fatty (70%). Screening mode was defined as screen-film mammography (SFM) and full-field digital mammography (FFDM). We examined trends of PPVs by MD, screening mode and age. We used logistic regression to estimate odds ratio (OR) of screen-detected breast cancer associated with MD among women recalled, adjusting for screening mode and age. PPV-1 and PPV-2 decreased by increasing MD, regardless of screening mode (p for trend breasts. Among women recalled, the adjusted OR of breast cancer decreased with increasing MD. Compared with women with fatty breasts, the OR was 0.90 (95% CI: 0.84-0.96) for those with medium dense breasts and 0.85 (95% CI: 0.76-0.95) for those with dense breasts. PPVs decreased by increasing MD. Fewer women needed to be recalled or undergo an invasive procedure to detect one breast cancer among those with fatty versus dense breasts in the screening program in Norway, 1996-2010. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  7. An analysis of the duplicate testing strategy of an Irish immunochemical FOBT colorectal cancer screening programme.

    LENUS (Irish Health Repository)

    Kelley, Leanne

    2013-06-10

    AIM: This study examined the relevance of using a two sample quantitative immunochemical faecal occult blood test (iFOBT or FIT) at a high cut off stringency by the first population-based colorectal cancer (CRC) pilot screening programme in Ireland. METHOD: Approximately ten thousand individuals between the ages of 50-74 years were invited to perform two consecutive FITs. These were analysed in tandem using the OC-Sensor and participants with at least one positive result with a haemoglobin cut off for positivity at 100 ng\\/ml were offered colonoscopy. RESULTS: A total of 5023 (52%) (2177 (43%) male; 2846 (57%) female) individuals with a median age of 64 years participated. At least one positive FIT test was detected from 514 (10%) individuals. From the 419 (82%) patients who proceeded to colonoscopy 17 (4%) had CRC and 132(33%) had an advanced adenoma. The detection rate for these screen relevant lesions was 3% (95% CIs = 2.5% - 3.5%) and the FIT positive + colonoscopy detection rate was 36% (95% CI = 31% - 40%). The numbers needed to colonoscope to find an advanced lesion was 2.8. The two test system detected four (23.5%) additional patients with CRC and 37 (28%) with an advanced adenoma compared with a single test. CONCLUSION: The CRC miss rate estimated for a single test (23.5%) was unacceptably high when the goal was to maximize the discovery of advanced lesions in the initial screening round. We conclude that the two test protocol at a high cut off threshold is suitable to optimize FIT screening in Ireland. This article is protected by copyright. All rights reserved.

  8. Screening physical health? Yes! But...: nurses' views on physical health screening in mental health care.

    Science.gov (United States)

    Happell, Brenda; Scott, David; Nankivell, Janette; Platania-Phung, Chris

    2013-08-01

    To explore nurses' views on the role of nurses in screening and monitoring for physical care of consumers with serious mental illness, at a regional mental health care service. People with serious mental illness experience heightened incidence of preventable and treatable physical illnesses such as cardiovascular disease and diabetes. Screening and monitoring are considered universal clinical safeguards. Nurses can potentially facilitate systematic screening, but their views on physical health care practices are rarely investigated. Qualitative exploratory study. Focus group interviews with 38 nurses of a regional mental health care service district of Australia. To facilitate discussion, participants were presented with a screening system, called the Health Improvement Profile (HIP), as an exemplar of screening of physical health risks by nurses. Inductive data analysis and theme development were guided by a thematic analysis framework. Nurses argued that treatable and preventable physical health problems were common. Four main themes were identified: screening - essential for good practice; the policy-practice gap; 'screening then what?' and, is HIP the answer? Screening and monitoring were considered crucial to proper diagnosis and treatment, however, were not performed systematically or consistently. Nurse readiness for an enhanced role in screening was shaped by: role and responsibility issues, legal liability concerns, funding and staff shortages. Participants were concerned that lack of follow up would limit effectiveness of these interventions. Screening was considered an important clinical step in effective diagnosis and treatment; however, identified barriers need to be addressed to ensure screening is part of a systemic approach to improve physical health of consumers with serious mental illness. Nurses have potential to influence improvement in physical health outcomes for consumers of mental health services. Such potential can only be realised if a

  9. Risks of Colorectal Cancer Screening

    Science.gov (United States)

    ... Genetics of Colorectal Cancer Colorectal Cancer Screening Research Colorectal Cancer Screening (PDQ®)–Patient Version What is screening? Go ... These are called diagnostic tests . General Information About Colorectal Cancer Key Points Colorectal cancer is a disease in ...

  10. Cervical cancer - screening and prevention

    Science.gov (United States)

    Cancer cervix - screening; HPV - cervical cancer screening; Dysplasia - cervical cancer screening; Cervical cancer - HPV vaccine ... Almost all cervical cancers are caused by HPV (human papilloma virus). HPV is a common virus that spreads through sexual contact. Certain ...

  11. Single borehole test sensitivity towards crack and rock parameter. Lesson Hortberg; Einbohrlochtracertestsensitivitaet gegenueber Riss und Gesteinsparametern. Lektion Horstberg

    Energy Technology Data Exchange (ETDEWEB)

    Ghergut, Iulia; Behrens, Horst; Sauter, Martin [Goettingen Univ. (Germany). Angewandte Geologie

    2012-10-16

    The novel experiments of the GeoZentrum Hanover (Hanover, Federal Republic of Germany) on geothermal energy at the well bore Horstberg in the south heath also motivated the accompanying tracertest-mindset to move away from the tracer job stereotypes. For some possible designs at the tracertest at this drilling (forced-gradient divergent push by water fracking of Detfurth perforation, single-screen push-pull at Solling perforation, single-screen push-pull at Detfurth perforation, and so forth) the analysis shows how and why the controlling parameter do not comply with the mental basic pattern of the expectations at the tracertests ('tracertest by crack {yields} characterization of the crack', 'tracer residence time {yields} prognosis of the thermal lifetime').

  12. Is it worthwhile to screen patients with type 2 diabetes mellitus for subclinical Cushing's syndrome?

    Science.gov (United States)

    Budyal, Sweta; Jadhav, Swati Sachin; Kasaliwal, Rajeev; Patt, Hiren; Khare, Shruti; Shivane, Vyankatesh; Lila, Anurag R; Bandgar, Tushar; Shah, Nalini S

    2015-01-01

    Variable prevalence of subclinical Cushing's syndrome (SCS) has been reported in patients with type 2 diabetes mellitus (T2DM), making the need for screening in this population uncertain. It is unknown if this variability is solely due to study-related methodological differences or a reflection of true differences in ethnic predisposition. The objective of this study is to explore the prevalence of SCS in Asian Indian patients with T2DM. In this prospective single center study conducted in a tertiary care referral center, 993 T2DM outpatients without any discriminatory clinical features (easy bruising, facial plethora, proximal muscle weakness, and/or striae) of hypercortisolism underwent an overnight 1 mg dexamethasone suppression test (ODST). ODST serum cortisol ≥1.8 μg/dl was considered positive, and those with positive results were subjected to 48 h, 2 mg/day low dose DST (LDDST). A stepwise evaluation for endogenous hypercortisolism was planned for patients with LDDST serum cortisol ≥1.8 μg/dl. Patients with positive ODST and negative LDDST were followed up clinically and re-evaluated a year later for the development of clinically evident Cushing's syndrome (CS). In this largest single center study reported to date, we found 37 out of 993 (3.72%) patients had ODST serum cortisol ≥1.8 μg/dl. None of them had LDDST cortisol ≥1.8 μg/dl, nor did they develop clinically evident CS over a follow-up period of 1 year. Specificity of ODST for screening of CS was 96.3% in our cohort. None of the T2DM outpatients in our cohort had SCS, hence cautioning against routine biochemical screening for SCS in this cohort. We suggest screening be based on clinical suspicion only. PMID:26420669

  13. Detection beyond the Debye screening length in a high-frequency nanoelectronic biosensor.

    Science.gov (United States)

    Kulkarni, Girish S; Zhong, Zhaohui

    2012-02-08

    Nanosensors based on the unique electronic properties of nanotubes and nanowires offer high sensitivity and have the potential to revolutionize the field of Point-of-Care (POC) medical diagnosis. The direct current (dc) detection of a wide array of organic and inorganic molecules has been demonstrated on these devices. However, sensing mechanism based on measuring changes in dc conductance fails at high background salt concentrations, where the sensitivity of the devices suffers from the ionic screening due to mobile ions present in the solution. Here, we successfully demonstrate that the fundamental ionic screening effect can be mitigated by operating single-walled carbon nanotube field effect transistor as a high-frequency biosensor. The nonlinear mixing between the alternating current excitation field and the molecular dipole field can generate mixing current sensitive to the surface-bound biomolecules. Electrical detection of monolayer streptavidin binding to biotin in 100 mM buffer solution is achieved at a frequency beyond 1 MHz. Theoretical modeling confirms improved sensitivity at high frequency through mitigation of the ionic screening effect. The results should promise a new biosensing platform for POC detection, where biosensors functioning directly in physiologically relevant condition are desired. © 2012 American Chemical Society

  14. Single-Nucleotide Polymorphism-Microarray Ploidy Analysis of Paraffin-Embedded Products of Conception in Recurrent Pregnancy Loss Evaluations.

    Science.gov (United States)

    Maslow, Bat-Sheva L; Budinetz, Tara; Sueldo, Carolina; Anspach, Erica; Engmann, Lawrence; Benadiva, Claudio; Nulsen, John C

    2015-07-01

    To compare the analysis of chromosome number from paraffin-embedded products of conception using single-nucleotide polymorphism (SNP) microarray with the recommended screening for the evaluation of couples presenting with recurrent pregnancy loss who do not have previous fetal cytogenetic data. We performed a retrospective cohort study including all women who presented for a new evaluation of recurrent pregnancy loss over a 2-year period (January 1, 2012, to December 31, 2013). All participants had at least two documented first-trimester losses and both the recommended screening tests and SNP microarray performed on at least one paraffin-embedded products of conception sample. Single-nucleotide polymorphism microarray identifies all 24 chromosomes (22 autosomes, X, and Y). Forty-two women with a total of 178 losses were included in the study. Paraffin-embedded products of conception from 62 losses were sent for SNP microarray. Single-nucleotide polymorphism microarray successfully diagnosed fetal chromosome number in 71% (44/62) of samples, of which 43% (19/44) were euploid and 57% (25/44) were noneuploid. Seven of 42 (17%) participants had abnormalities on recurrent pregnancy loss screening. The per-person detection rate for a cause of pregnancy loss was significantly higher in the SNP microarray (0.50; 95% confidence interval [CI] 0.36-0.64) compared with recurrent pregnancy loss evaluation (0.17; 95% CI 0.08-0.31) (P=.002). Participants with one or more euploid loss identified on paraffin-embedded products of conception were significantly more likely to have an abnormality on recurrent pregnancy loss screening than those with only noneuploid results (P=.028). The significance remained when controlling for age, number of losses, number of samples, and total pregnancies. These results suggest that SNP microarray testing of paraffin-embedded products of conception is a valuable tool for the evaluation of recurrent pregnancy loss in patients without prior fetal

  15. Screening diagnostic program breast cancer

    International Nuclear Information System (INIS)

    Portnoj, L.M.; Zhakova, I.I.; Budnikova, N.V.; Rukhlyadko, E.D.

    1995-01-01

    The authors propose their screening program for detection of breast cancer. It includes the entire complex of present-day screening diagnostic methods, starting from an original system for the formation of groups at risk of breast cancer and completed by the direct diagnostic model of detection of the condition, oriented at a differentiated approach to the use of mammographic techniques. The proposed organizational and methodologic screening measures are both economic and diagnostically effective, thus meeting the principal requirements to screening programs. Screening of 8541 risk-groups patients helped detect 867 nodular formations, 244 of which were cancer and 623 benign formations. 8 refs., 3 figs.,

  16. A systematic review of hepatitis B screening economic evaluations in low- and middle-income countries.

    Science.gov (United States)

    Wright, Cameron M; Boudarène, Lydia; Ha, Ninh Thi; Wu, Olivia; Hawkins, Neil

    2018-03-20

    Chronic hepatitis B infection is a significant cause of morbidity and mortality worldwide; low- and middle-income countries (LMICs) are disproportionately affected. Economic evaluations are a useful decision tool to assess costs versus benefits of hepatitis B virus (HBV) screening. No published study reviewing economic evaluations of HBV screening in LMICs has been undertaken to date. The following databases were searched from inception to 21 April 2017: MEDLINE, PubMed, EMBASE, CINAHL Plus, the Cochrane Library, Global Health and the Cost-effectiveness Analysis Registry. English-language studies were included if they assessed the costs against the benefits of HBV screening in LMICs. PROSPERO registration: CRD42015024391, 20 July 2015. Nine studies fulfilled the eligibility criteria. One study from Thailand indicated that adding hepatitis B immunoglobulin (HBIG) to HBV vaccination for newborns following screening of pregnant women might be cost-effective for some LMICs, though inadequate total funding and health infrastructure were likely to limit feasibility. A similar study from China indicated a benefit to cost ratio of 2.7 from selective HBIG administration to newborns, if benefits were considered from a societal perspective. Of the two studies assessing screening amongst the general adult population, a single cost-benefit analysis from China found a benefit to cost ratio (BCR) of 1.73 with vaccination guided by HBV screening of adults aged 21-39, compared to 1.42 with vaccination with no screening, both from a societal perspective. Community-based screening of adults in The Gambia with linkage to treatment yielded an incremental cost per disability-adjusted life year averted of $566 (in 2017 USD), less than two-times gross domestic product per capita for that country. Screening with 'catch-up' vaccination for younger adults yielded benefits above costs, and screening linked with treatment has shown cost-effectiveness that may be affordable for some LMICs

  17. The comparative evaluation of film-screen combinations

    International Nuclear Information System (INIS)

    Choi, Gyung Ja; Choi, Syng Kyu

    1988-01-01

    This study was to compare the quality of image by different screen and film combinations. Using the sensitometer measured the speed and average gradient of blue sensitive films and orthochromatic films. The films was combined with rare earth screen LR, Lm, LF and conventional screen OM, OH, XOR, OKa and exposed the stepwedge to impulse 2, 3, 4, 6, 10, 15, 24, 38, 60 and measured the density. The following results were obtained: 1. The density of film and film-screen combinations showed significant difference, then in film-screen combinations was significantly different by the screens than films. 2. The speed of blue sensitive films was little different, the TMG of orthochromatic films producted high speed, and the AX films was high average gradient. 3. The relative speed of film-screen combinations showed significant difference, and was high in the OKa of the conventional screens and in the LR of the rare earth screens, especially that of LR screen in the combination with blue sensitive films was high. 4. The average gradient of film-screen combinations showed no significant difference, and was high in the OKa screen and LR/OG combination, and that of OKa/AX combination was highest. 5. The latitude of film-screen combinations showed significant difference by screens, and was high in the LM screen in combination with blue sensitive films and in the OM screen in combination with orthochromatic films. 6. The subject contrast of film-screen combinations showed significant difference by screen, and was high in the LR screen in combination with blue sensitive AX film and orthochromatic TMG film.

  18. Screening of specific nucleic acid aptamers binding tumor markers in the serum of the lung cancer patients and identification of their activities.

    Science.gov (United States)

    Li, Kun; Xiu, Chen-Lin; Gao, Li-Ming; Liang, Hua-Gang; Xu, Shu-Feng; Shi, Ming; Li, Jian; Liu, Zhi-Wei

    2017-07-01

    Lung cancer is by far the leading cause of cancer death in the world. Despite the improvements in diagnostic methods, the status of early detection was not achieved. So, a new diagnostic method is needed. The aim of this study is to obtain the highly specific nucleic acid aptamers with strong affinity to tumor markers in the serum of the lung cancer patients for targeting the serum. Aptamers specifically binding to tumor markers in the serum of the lung cancer patients were screened from the random single-stranded DNA library with agarose beads as supports and the serum as a target by target-substituting subtractive SELEX technique and real-time quantitative polymerase chain reaction technique. Subsequently, the secondary single-stranded DNA library obtained by 10 rounds of screening was amplified to double-stranded DNA, followed by high-throughput genome sequence analysis to screen aptamers with specific affinity to tumor markers in the serum of the lung cancer patients. Finally, six aptamers obtained by 10 rounds of screening were identified with high specific affinity to tumor markers in the serum of the lung cancer patients. Compared with other five aptamers, the aptamer 43 was identified both with the highest specificity to bind target molecule and without any obvious affinity to non-specific proteins. The screened aptamers have relatively high specificity to combine tumor markers in the serum of the lung cancer patients, which provides breakthrough points for early diagnosis and treatment of lung cancer.

  19. Colorectal cancer mortality 10 years after a single round of guaiac faecal occult blood test (gFOBT) screening

    DEFF Research Database (Denmark)

    Bjerrum, Andreas; Andersen, Ole; Fischer, Anders

    2016-01-01

    BACKGROUND: In Denmark, colorectal cancer (CRC) is the third most frequent cancer. Randomised trials have shown that guaiac faecal occult blood test (gFOBT) screening can reduce CRC mortality, but a recent large randomised study from Finland did not find any effect. A feasibility study was carried...

  20. Smoking cessation and lung cancer screening

    DEFF Research Database (Denmark)

    Pedersen, Jesper Johannes Holst; Tønnesen, Philip; Ashraf, Haseem

    2016-01-01

    Smoking behavior may have a substantial influence on the overall effect of lung cancer screening. Non-randomized studies of smoking behavior during screening have indicated that computer tomography (CT) screening induces smoking cessation. Randomized studies have further elaborated that this effect...... and decrease smoking relapse rate. Also low smoking dependency and high motivation to quit smoking at baseline predicted smoking abstinence in screening trials. Lung cancer screening therefore seems to be a teachable moment for smoking cessation. Targeted smoking cessation counselling should be an integrated...... part of future lung cancer screening trials....

  1. The association of colonoscopy quality indicators with the detection of screen-relevant lesions, adverse events, and postcolonoscopy cancers in an asymptomatic Canadian colorectal cancer screening population.

    Science.gov (United States)

    Hilsden, Robert J; Dube, Catherine; Heitman, Steven J; Bridges, Ronald; McGregor, S Elizabeth; Rostom, Alaa

    2015-11-01

    Although several quality indicators of colonoscopy have been defined, quality assurance activities should be directed at the measurement of quality indicators that are predictive of key screening colonoscopy outcomes. The goal of this study was to examine the association among established quality indicators and the detection of screen-relevant lesions (SRLs), adverse events, and postcolonoscopy cancers. Historical cohort study. Canadian colorectal cancer screening center. A total of 18,456 asymptomatic men and women ages 40 to 74, at either average risk or increased risk for colorectal cancer because of a family history, who underwent a screening colonoscopy from 2008 to 2010. Using univariate and multivariate analyses, we explored the association among procedural quality indicators and 3 colonoscopy outcomes: detection of SRLs, adverse events, and postcolonoscopy cancers. The crude rates of SRLs, adverse events, and postcolonoscopy cancers were 240, 6.44, and .54 per 1000 colonoscopies, respectively. Several indicators, including endoscopist withdrawal time (OR, 1.3; 95% CI, 1.2-1.4) and cecal intubation rate (OR, 13.9; 95% CI, 1.9-96.9), were associated with the detection of SRLs. No quality indicator was associated with the risk of adverse events. Endoscopist average withdrawal time over 6 minutes (OR, .12; 95% CI, .002-.85) and SRL detection rate over 20% (OR, .17; 95% CI, .03-.74) were associated with a reduced risk of postcolonoscopy cancers. Single-center study. Quality assurance programs should prioritize the measurement of endoscopist average withdrawal time and adenoma (SRL) detection rate. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  2. Newborn Screening for Severe Combined Immunodeficiency in 11 Screening Programs in the United States

    Science.gov (United States)

    Kwan, Antonia; Abraham, Roshini S.; Currier, Robert; Brower, Amy; Andruszewski, Karen; Abbott, Jordan K.; Baker, Mei; Ballow, Mark; Bartoshesky, Louis E.; Bonagura, Vincent R.; Bonilla, Francisco A.; Brokopp, Charles; Brooks, Edward; Caggana, Michele; Celestin, Jocelyn; Church, Joseph A.; Comeau, Anne Marie; Connelly, James A.; Cowan, Morton J.; Cunningham-Rundles, Charlotte; Dasu, Trivikram; Dave, Nina; De La Morena, Maria T.; Duffner, Ulrich; Fong, Chin-To; Forbes, Lisa; Freedenberg, Debra; Gelfand, Erwin W.; Hale, Jaime E.; Celine Hanson, I.; Hay, Beverly N.; Hu, Diana; Infante, Anthony; Johnson, Daisy; Kapoor, Neena; Kay, Denise M.; Kohn, Donald B.; Lee, Rachel; Lehman, Heather; Lin, Zhili; Lorey, Fred; Abdel-Mageed, Aly; Manning, Adrienne; McGhee, Sean; Moore, Theodore B.; Naides, Stanley J.; Notarangelo, Luigi D.; Orange, Jordan S.; Pai, Sung-Yun; Porteus, Matthew; Rodriguez, Ray; Romberg, Neil; Routes, John; Ruehle, Mary; Rubenstein, Arye; Saavedra-Matiz, Carlos A.; Scott, Ginger; Scott, Patricia M.; Secord, Elizabeth; Seroogy, Christine; Shearer, William T.; Siegel, Subhadra; Silvers, Stacy K.; Stiehm, E. Richard; Sugerman, Robert W.; Sullivan, John L.; Tanksley, Susan; Tierce, Millard L.; Verbsky, James; Vogel, Beth; Walker, Rosalyn; Walkovich, Kelly; Walter, Jolan E.; Wasserman, Richard L.; Watson, Michael S.; Weinberg, Geoffrey A.; Weiner, Leonard B.; Wood, Heather; Yates, Anne B.; Puck, Jennifer M.

    2015-01-01

    IMPORTANCE Newborn screening for severe combined immunodeficiency (SCID) using assays to detect T-cell receptor excision circles (TRECs) began in Wisconsin in 2008, and SCID was added to the national recommended uniform panel for newborn screened disorders in 2010. Currently 23 states, the District of Columbia, and the Navajo Nation conduct population-wide newborn screening for SCID. The incidence of SCID is estimated at 1 in 100 000 births. OBJECTIVES To present data from a spectrum of SCID newborn screening programs, establish population-based incidence for SCID and other conditions with T-cell lymphopenia, and document early institution of effective treatments. DESIGN Epidemiological and retrospective observational study. SETTING Representatives in states conducting SCID newborn screening were invited to submit their SCID screening algorithms, test performance data, and deidentified clinical and laboratory information regarding infants screened and cases with nonnormal results. Infants born from the start of each participating program from January 2008 through the most recent evaluable date prior to July 2013 were included. Representatives from 10 states plus the Navajo Area Indian Health Service contributed data from 3 030 083 newborns screened with a TREC test. MAIN OUTCOMES AND MEASURES Infants with SCID and other diagnoses of T-cell lymphopenia were classified. Incidence and, where possible, etiologies were determined. Interventions and survival were tracked. RESULTS Screening detected 52 cases of typical SCID, leaky SCID, and Omenn syndrome, affecting 1 in 58 000 infants (95%CI, 1/46 000-1/80 000). Survival of SCID-affected infants through their diagnosis and immune reconstitution was 87%(45/52), 92%(45/49) for infants who received transplantation, enzyme replacement, and/or gene therapy. Additional interventions for SCID and non-SCID T-cell lymphopenia included immunoglobulin infusions, preventive antibiotics, and avoidance of live vaccines. Variations in

  3. Lung cancer screening: Update

    International Nuclear Information System (INIS)

    Kim, Hyea Young

    2015-01-01

    Lung cancer is the leading cause of cancer deaths worldwide as well as in Korea. A recent National Lung Screening Trial in U.S. revealed that low-dose CT (LDCT) screening reduced lung cancer specific mortality by 20% in high risk individuals as compared to chest radiograph screening. Based on this evidence, several expert societies in U.S. and Korean multisociety collaborative committee developed guidelines for recommendation of lung cancer screening using annual LDCT in high risk populations. In most of the societies high risk groups are defined as persons aged 55 to 74 years, who are current smokers with history of smoking of more than 30 packs per year or ex-smokers, who quit smoking up to 15 or more years ago. The benefits of LDCT screening are modestly higher than the harms in high risk individuals. The harms included a high rate of false-positive findings, over-diagnosis and radiation-related deaths. Invasive diagnostic procedure due to false positive findings may lead to complications. LDCT should be performed in qualified hospitals and interpreted by expert radiologists. Recently, the American College of Radiology released the current version of Lung cancer CT screening Reporting and Data Systems. Education and actions to stop smoking must be offered to current smokers

  4. Lung cancer screening: Update

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyea Young [Dept. of Radiology, Center for Lung Cancer, National Cancer Center, Goyang (Korea, Republic of)

    2015-09-15

    Lung cancer is the leading cause of cancer deaths worldwide as well as in Korea. A recent National Lung Screening Trial in U.S. revealed that low-dose CT (LDCT) screening reduced lung cancer specific mortality by 20% in high risk individuals as compared to chest radiograph screening. Based on this evidence, several expert societies in U.S. and Korean multisociety collaborative committee developed guidelines for recommendation of lung cancer screening using annual LDCT in high risk populations. In most of the societies high risk groups are defined as persons aged 55 to 74 years, who are current smokers with history of smoking of more than 30 packs per year or ex-smokers, who quit smoking up to 15 or more years ago. The benefits of LDCT screening are modestly higher than the harms in high risk individuals. The harms included a high rate of false-positive findings, over-diagnosis and radiation-related deaths. Invasive diagnostic procedure due to false positive findings may lead to complications. LDCT should be performed in qualified hospitals and interpreted by expert radiologists. Recently, the American College of Radiology released the current version of Lung cancer CT screening Reporting and Data Systems. Education and actions to stop smoking must be offered to current smokers.

  5. Measuring lip force by oral screens. Part 1: Importance of screen size and individual variability.

    Science.gov (United States)

    Wertsén, Madeleine; Stenberg, Manne

    2017-06-01

    To reduce drooling and facilitate food transport in rehabilitation of patients with oral motor dysfunction, lip force can be trained using an oral screen. Longitudinal studies evaluating the effect of training require objective methods. The aim of this study was to evaluate a method for measuring lip strength, to investigate normal values and fluctuation of lip force in healthy adults on 1 occasion and over time, to study how the size of the screen affects the force, to evaluate the most appropriate measure of reliability, and to identify force performed in relation to gender. Three different sizes of oral screens were used to measure the lip force for 24 healthy adults on 3 different occasions, during a period of 6 months, using an apparatus based on strain gauge. The maximum lip force as evaluated with this method depends on the area of the screen size. By calculating the projected area of the screen, the lip force could be normalized to an oral screen pressure quantity expressed in kPa, which can be used for comparing measurements from screens with different sizes. Both the mean value and standard deviation were shown to vary between individuals. The study showed no differences regarding gender and only small variation with age. Normal variation over time (months) may be up to 3 times greater than the standard error of measurement at a certain occasion. The lip force increases in relation to the projected area of the screen. No general standard deviation can be assigned to the method and all measurements should be analyzed individually based on oral screen pressure to compensate for different screen sizes.

  6. [Organized breast cancer screening].

    Science.gov (United States)

    Rouëssé, Jacques; Sancho-Garnier, Hélèn

    2014-02-01

    Breast screening programs are increasingly controversial, especially regarding two points: the number of breast cancer deaths they avoid, and the problem of over-diagnosis and over-treatment. The French national breast cancer screening program was extended to cover the whole country in 2004. Ten years later it is time to examine the risk/benefit ratio of this program and to discuss the need for change. Like all forms of cancer management, screening must be regularly updated, taking into account the state of the art, new evidence, and uncertainties. All screening providers should keep themselves informed of the latest findings. In the French program, women aged 50-74 with no major individual or familial risk factors for breast cancer are offered screening mammography and clinical breast examination every two years. Images considered non suspicious of malignancy by a first reader are re-examined by a second reader. The devices and procedures are subjected to quality controls. Participating radiologists (both public and private) are required to read at least 500 mammographies per year. The program's national participation rate was 52.7 % in 2012. When individual screening outside of the national program is taken into account (nearly 15 % of women), coverage appears close to the European recommendation of 65 %. Breast cancer mortality has been falling in France by 0.6 % per year for over 30 years, starting before mass screening was implemented, and by 1.5 % since 2005. This decline can be attributed in part to earlier diagnosis and better treatment, so that the specific impact of screening cannot easily be measured. Over-treatment, defined as the detection and treatment of low-malignancy tumors that would otherwise not have been detected in a person's lifetime, is a major negative effect of screening, but its frequency is not precisely known (reported to range from 1 % to 30 %). In view of these uncertainties, it would be advisable to modify the program in order to

  7. Micro-motor with screen-printed rotor magnets

    International Nuclear Information System (INIS)

    Speliotis, Thanassis; Niarchos, Dimitris; Meneroud, Patrick; Magnac, G.; Claeyssen, Franck; Pepin, John; Fermon, Claude; Pannetier, M.; Biziere, N.

    2007-01-01

    The feasibility to develop mini- and micro-magnetic electro-mechanical systems (MEMS) has been evaluated by prototyping of a single-phase stepper motor. The main targeted application of such device is the watch industry needing micro-motors in huge quantities at low cost. The motor part that required the greatest efforts has been the magnet, which cannot yet be found in film layer. The screen-printing technology has been used for the production of NdFeB-based magnets whose properties have been characterised. The thick film magnets have been integrated in the stepper motor specially designed for this purpose. The whole motor has been characterised and conclusions are drawn on the possibility of producing thick film magnets for magnetic MEMS

  8. Simple Screening Methods for Drought and Heat Tolerance in Cowpea

    International Nuclear Information System (INIS)

    Singh, B. B.

    2000-10-01

    Success in breeding for drought tolerance has not been as pronounced as for other traits. This is partly due to lack of simple, cheap and reliable screening methods to select drought tolerant plants/progenies from the segregating populations and partly due to complexity of factors involved in drought tolerance. Measuring drought tolerance through physiological parameters is expensive, time consuming and difficult to use for screening large numbers of lines and segregating populations. Since several factors/mechanisms (in shoot and root) operate independently and/or jointly to enable plants to cope with drought stress, drought tolerance appears as a complex trait. However, if these factors/mechanisms can be separated and studied individually, the components leading to drought tolerance will appear less complex and may be easy to manipulate by breeders. We have developed a simple box screening method for shoot drought tolerance in cowpea, which eliminates the effects of roots and permits non-destructive visual identification of shoot dehydration tolerance. We have also developed a 'root-box pin-board' method to study two dimensional root architecture of individual plants. Using these methods, we have identified two mechanisms of shoot drought tolerance in cowpea which are controlled by single dominant genes and major difference for root architecture among cowpea varieties. Combining deep and dense root system with shoot dehydration tolerance results into highly drought tolerant plants

  9. Factors Influencing Colorectal Cancer Screening Participation

    Directory of Open Access Journals (Sweden)

    Antonio Z. Gimeno García

    2012-01-01

    Full Text Available Colorectal cancer (CRC is a major health problem worldwide. Although population-based CRC screening is strongly recommended in average-risk population, compliance rates are still far from the desirable rates. High levels of screening uptake are necessary for the success of any screening program. Therefore, the investigation of factors influencing participation is crucial prior to design and launches a population-based organized screening campaign. Several studies have identified screening behaviour factors related to potential participants, providers, or health care system. These influencing factors can also be classified in non-modifiable (i.e., demographic factors, education, health insurance, or income and modifiable factors (i.e., knowledge about CRC and screening, patient and provider attitudes or structural barriers for screening. Modifiable determinants are of great interest as they are plausible targets for interventions. Interventions at different levels (patient, providers or health care system have been tested across the studies with different results. This paper analyzes factors related to CRC screening behaviour and potential interventions designed to improve screening uptake.

  10. Utility of supplemental screening with breast ultrasound in asymptomatic women with dense breast tissue who are not at high risk for breast cancer

    OpenAIRE

    Klevos, Geetika A; Collado-Mesa, Fernando; Net, Jose M; Yepes, Monica M

    2017-01-01

    Objective: To assess the results of an initial round of supplemental screening with hand-held bilateral breast ultrasound following a negative screening mammogram in asymptomatic women with dense breast tissue who are not at high risk for breast cancer. Materials and Methods: A retrospective, Health Insurance Portability and Accountability Act compliant, Institutional Research Board approved study was performed at a single academic tertiary breast center. Informed consent was waived. A system...

  11. CRISPR library designer (CLD): software for multispecies design of single guide RNA libraries.

    Science.gov (United States)

    Heigwer, Florian; Zhan, Tianzuo; Breinig, Marco; Winter, Jan; Brügemann, Dirk; Leible, Svenja; Boutros, Michael

    2016-03-24

    Genetic screens using CRISPR/Cas9 are a powerful method for the functional analysis of genomes. Here we describe CRISPR library designer (CLD), an integrated bioinformatics application for the design of custom single guide RNA (sgRNA) libraries for all organisms with annotated genomes. CLD is suitable for the design of libraries using modified CRISPR enzymes and targeting non-coding regions. To demonstrate its utility, we perform a pooled screen for modulators of the TNF-related apoptosis inducing ligand (TRAIL) pathway using a custom library of 12,471 sgRNAs. CLD predicts a high fraction of functional sgRNAs and is publicly available at https://github.com/boutroslab/cld.

  12. Screening for autistic spectrum disorder in children aged 14-15 months. II: population screening with the Early Screening of Autistic Traits Questionnaire (ESAT). Design and general findings.

    NARCIS (Netherlands)

    Dietz, C.; Swinkels, S.H.N.; Daalen, E. van; Engeland, H.M. van; Buitelaar, J.K.

    2006-01-01

    A two-stage protocol for screening for autistic spectrum disorders (ASD) was evaluated in a random population of 31,724 children aged 14-15 months. Children were first pre-screened by physicians at well-baby clinics using a 4-item screening instrument. Infants that screened positive were then

  13. Single exposure simultaneous acquisition of digital and conventional radiographs utilizing unaltered dose

    International Nuclear Information System (INIS)

    Oestmann, J.W.; Greene, R.

    1988-01-01

    We describe the simultaneous acquisition of digital and conventional radiographs with a single standard radiographic exposure. A digitizable storage phosphor (ST Imaging Plate, Fuji) is sandwiched into a radiographic cassette (X-Omatic, Kodak) behind a conventional radiographic film-screen combination (Lanex medium screens, OC film, Kodak). The barium fluorohalide storage phosphor is digitized with a helium-neon laser scanner (TCR 201, Toshiba), and the conventional radiograph is processed in the standard fashion (M7B, Kodak). The storage phosphor is exposed by the 'wasted' radiation normally exiting the back of the film-screen combination (32% of the cassette entrance dose at 141 kVp). At a standard exposure (6.3 mAs), the conventional radiograph is of unaltered quality, and the digital image appears to have an adequate signal-to-noise ratio for chest studies despite the lower exposure dose. This technique produces twin images of identical spatial and temporal registration and avoids the added radiation exposure normally required to carry out comparative studies. (orig.)

  14. Can data science inform environmental justice and community risk screening for type 2 diabetes?

    Science.gov (United States)

    Davis, J Allen; Burgoon, Lyle D

    2015-01-01

    Having the ability to scan the entire country for potential "hotspots" with increased risk of developing chronic diseases due to various environmental, demographic, and genetic susceptibility factors may inform risk management decisions and enable better environmental public health policies. Develop an approach for community-level risk screening focused on identifying potential genetic susceptibility hotpots. Our approach combines analyses of phenotype-genotype data, genetic prevalence of single nucleotide polymorphisms, and census/geographic information to estimate census tract-level population attributable risks among various ethnicities and total population for the state of California. We estimate that the rs13266634 single nucleotide polymorphism, a type 2 diabetes susceptibility genotype, has a genetic prevalence of 56.3%, 47.4% and 37.0% in Mexican Mestizo, Caucasian, and Asian populations. Looking at the top quintile for total population attributable risk, 16 California counties have greater than 25% of their population living in hotspots of genetic susceptibility for developing type 2 diabetes due to this single genotypic susceptibility factor. This study identified counties in California where large portions of the population may bear additional type 2 diabetes risk due to increased genetic prevalence of a susceptibility genotype. This type of screening can easily be extended to include information on environmental contaminants of interest and other related diseases, and potentially enables the rapid identification of potential environmental justice communities. Other potential uses of this approach include problem formulation in support of risk assessments, land use planning, and prioritization of site cleanup and remediation actions.

  15. Lung cancer incidence and mortality in National Lung Screening Trial participants who underwent low-dose CT prevalence screening: a retrospective cohort analysis of a randomised, multicentre, diagnostic screening trial.

    Science.gov (United States)

    Patz, Edward F; Greco, Erin; Gatsonis, Constantine; Pinsky, Paul; Kramer, Barnett S; Aberle, Denise R

    2016-05-01

    Annual low-dose CT screening for lung cancer has been recommended for high-risk individuals, but the necessity of yearly low-dose CT in all eligible individuals is uncertain. This study examined rates of lung cancer in National Lung Screening Trial (NLST) participants who had a negative prevalence (initial) low-dose CT screen to explore whether less frequent screening could be justified in some lower-risk subpopulations. We did a retrospective cohort analysis of data from the NLST, a randomised, multicentre screening trial comparing three annual low-dose CT assessments with three annual chest radiographs for the early detection of lung cancer in high-risk, eligible individuals (aged 55-74 years with at least a 30 pack-year history of cigarette smoking, and, if a former smoker, had quit within the past 15 years), recruited from US medical centres between Aug 5, 2002, and April 26, 2004. Participants were followed up for up to 5 years after their last annual screen. For the purposes of this analysis, our cohort consisted of all NLST participants who had received a low-dose CT prevalence (T0) screen. We determined the frequency, stage, histology, study year of diagnosis, and incidence of lung cancer, as well as overall and lung cancer-specific mortality, and whether lung cancers were detected as a result of screening or within 1 year of a negative screen. We also estimated the effect on mortality if the first annual (T1) screen in participants with a negative T0 screen had not been done. The NLST is registered with ClinicalTrials.gov, number NCT00047385. Our cohort consisted of 26 231 participants assigned to the low-dose CT screening group who had undergone their T0 screen. The 19 066 participants with a negative T0 screen had a lower incidence of lung cancer than did all 26 231 T0-screened participants (371·88 [95% CI 337·97-408·26] per 100 000 person-years vs 661·23 [622·07-702·21]) and had lower lung cancer-related mortality (185·82 [95% CI 162·17

  16. New generation expandable sand screens

    OpenAIRE

    Syltøy, Christer

    2014-01-01

    Master's thesis in Petroleum engineering This thesis aims to give a general insight into sand control and various sorts of sand control measures and applications of sand control tools. Special focus will be given to expandable sand screens – a technology which came about in the late 1990’s through the use of flexible, expandable tubulars as base pipe in sand screens. More specifically Darcy’s Hydraulic Endurance Screens, a compliant sand screen system using hydraulic activation, and the fu...

  17. How is adults' screen time behaviour influencing their views on screen time restrictions for children? A cross-sectional study.

    Science.gov (United States)

    Schoeppe, Stephanie; Rebar, Amanda L; Short, Camille E; Alley, Stephanie; Van Lippevelde, Wendy; Vandelanotte, Corneel

    2016-03-01

    High screen time in children and its detrimental health effects is a major public health problem. How much screen time adults think is appropriate for children remains little explored, as well as whether adults' screen time behaviour would determine their views on screen time restrictions for children. This study aimed to investigate how adults' screen time behaviour influences their views on screen time restrictions for children, including differences by gender and parental status. In 2013, 2034 Australian adults participated in an online survey conducted by the Population Research Laboratory at Central Queensland University, Rockhampton. Adult screen time behaviour was assessed using the Workforce Sitting Questionnaire. Adults reported the maximum time children aged between 5-12 years should be allowed to spend watching TV and using a computer. Ordinal logistic regression was used to compare adult screen time behaviour with views on screen time restrictions for children. Most adults (68%) held the view that children should be allowed no more than 2 h of TV viewing and computer use on school days, whilst fewer adults (44%) thought this screen time limit is needed on weekend days. Women would impose higher screen time restrictions for children than men (p 2 h on watching TV and using the computer at home on work days (66%) and non-work days (88%). Adults spending ≤ 2 h/day in leisure-related screen time were less likely to permit children > 2 h/day of screen time. These associations did not differ by adult gender and parental status. Most adults think it is appropriate to limit children's screen time to the recommended ≤ 2 h/day but few adults themselves adhere to this screen time limit. Adults with lower screen use may be more inclined to limit children's screen time. Strategies to reduce screen time in children may also need to target adult screen use.

  18. Phenylketonuria in The Netherlands : 93% of the mutations are detected by single-strand conformation analysis

    NARCIS (Netherlands)

    vanderSijsBos, CJM; Diepstraten, CM; Juyn, JA; Plaisier, M; Giltay, JC; vanSpronsen, FJ; Smit, GPA; Berger, R; Smeitink, JAM; PollThe, BT; vanAmstel, JKP

    1996-01-01

    Single-strand conformational analysis was used to screen for genetic defects in all thirteen exons of the phenylalanine hydroxylase gene (PAH) in phenylketonuria and hyperphenylalaninemia patients in the Netherlands. Exons that showed a bandshift were sequenced directly, In this way, we were able to

  19. More misinformation on breast cancer screening

    OpenAIRE

    Kopans, Daniel B.

    2017-01-01

    Unfortunately, a great deal of misinformation has accumulated in the breast cancer screening literature that is based on flawed analyses in an effort to reduce access to screening. Quite remarkably, much of this has come from publications in previously highly respected medical journals. In several papers the intervention (mammography screening) is faulted yet the analyses provided no data on who participated in mammography screening, and which cancers were detected by mammography screening. I...

  20. Time of flight secondary ion mass spectrometry: A powerful high throughput screening tool

    International Nuclear Information System (INIS)

    Smentkowski, Vincent S.; Ostrowski, Sara G.

    2007-01-01

    Combinatorial materials libraries are becoming more complicated; successful screening of these libraries requires the development of new high throughput screening methodologies. Time of flight secondary ion mass spectrometry (ToF-SIMS) is a surface analytical technique that is able to detect and image all elements (including hydrogen which is problematic for many other analysis instruments) and molecular fragments, with high mass resolution, during a single measurement. Commercial ToF-SIMS instruments can image 500 μm areas by rastering the primary ion beam over the region of interest. In this work, we will show that large area analysis can be performed, in one single measurement, by rastering the sample under the ion beam. We show that an entire 70 mm diameter wafer can be imaged in less than 90 min using ToF-SIMS stage (macro)rastering techniques. ToF-SIMS data sets contain a wealth of information since an entire high mass resolution mass spectrum is saved at each pixel in an ion image. Multivariate statistical analysis (MVSA) tools are being used in the ToF-SIMS community to assist with data interpretation; we will demonstrate that MVSA tools provide details that were not obtained using manual (univariate) analysis

  1. Screening for Cervical Cancer

    Science.gov (United States)

    Understanding Task Force Recommendations Screening for Cervical Cancer The U.S. Preventive Services Task Force (Task Force) has issued final recommendations on Screening for Cervical Cancer . These recommendations are for women ...

  2. European Society of Veterinary Cardiology screening guidelines for dilated cardiomyopathy in Doberman Pinschers.

    Science.gov (United States)

    Wess, G; Domenech, O; Dukes-McEwan, J; Häggström, J; Gordon, S

    2017-10-01

    Dilated cardiomyopathy (DCM) is the most common cardiac disease in large breed dogs and is inherited in Doberman Pinschers with a high prevalence (58%). The European Society for Veterinary Cardiology convened a task force to formulate screening guidelines for DCM in Dobermans. Screening for occult DCM in Dobermans should start at three years of age and use both Holter monitoring and echocardiography. Yearly screening over the life of the dog is recommended, as a one-time screening is not sufficient to rule out future development of DCM. The preferred echocardiographic method is the measurement of the left ventricular volume by Simpson's method of discs (SMOD). Less than 50 single ventricular premature complexes (VPCs) in 24 h are considered to be normal in Dobermans, although detection of any number of VPCs is cause for concern. Greater than 300 VPCs in 24 h or two subsequent recordings within a year showing between 50 and 300 VPCs in 24 h is considered diagnostic of occult DCM in Dobermans regardless of the concurrent echocardiographic findings. The guidelines also provide recommendations concerning ancillary tests, that are not included in the standard screening protocol, but which may have some utility when recommended tests are not available or financially untenable on an annual basis. These tests include assay of cardiac biomarkers (Troponin I and N-Terminal pro-B-type Natriuretic Peptide) as well as a 5-min resting electrocardiogram (ECG). The current guidelines should help to establish an early diagnosis of DCM in Dobermans. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  3. Affinity-based screening of combinatorial libraries using automated, serial-column chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Evans, D.M.; Williams, K.P.; McGuinness, B. [PerSeptive Biosystems, Framingham, MA (United States)] [and others

    1996-04-01

    The authors have developed an automated serial chromatographic technique for screening a library of compounds based upon their relative affinity for a target molecule. A {open_quotes}target{close_quotes} column containing the immobilized target molecule is set in tandem with a reversed-phase column. A combinatorial peptide library is injected onto the target column. The target-bound peptides are eluted from the first column and transferred automatically to the reversed-phase column. The target-specific peptide peaks from the reversed-phase column are identified and sequenced. Using a monoclonal antibody (3E-7) against {beta}-endorphin as a target, we selected a single peptide with sequence YGGFL from approximately 5800 peptides present in a combinatorial library. We demonstrated the applicability of the technology towards selection of peptides with predetermined affinity for bacterial lipopolysaccharide (LPS, endotoxin). We expect that this technology will have broad applications for high throughput screening of chemical libraries or natural product extracts. 21 refs., 4 figs.

  4. [Construction of a phage antibody library and screening of anti-epidermal growth factor receptor variant III single chain antibody].

    Science.gov (United States)

    Han, Dong-gang; Duan, Xiao-yi; Guo, You-min; Zhou, Qi; Wang, Quan-ying; Yang, Guang-xiao

    2010-01-01

    To obtain specific anti-epidermal growth factor receptor variant III (EGFRvIII) single chain antibody (ScFv) by phage antibody library display system. The total RNA was extracted from the spleen B cells of BALB/c mice immunized with pep-3-OVA protein, and the first-strand cDNA was synthesized by reverse transcription. Antibody VH and VL gene fragments were amplified and joined to a ScFv gene with the linker. The ScFv gene was ligated into the phagemid vector pCANTAB5E, which was transformed into competent E. coli TG1. The transformed cells were then infected with M13KO7 helper phage to yield the recombinant phage to construct the phage ScFv library. Pep-3-BSA protein was used to screen the phage antibody library and ELISA carried out to characterize the activity of the antibody. The VH and VL gene fragments of the antibody were about 350 bp and 320 bp in length as analyzed by agarose gel electrophoresis. The ScFv gene was 780 bp, consistent with the expected length. The recombinant phagemid with ScFv gene insert was rescued, and an immune phage ScFv library with the content of 5.0x10(6) was constructed. The recombinant ScFv phage had a titer of 3.0x10(4) cfu/ml, and the fourth phage harvest yielded 56 times as much as that of the first one. SDS-PAGE demonstrated a molecular mass of the soluble ScFv of about 28 kD. ELISA results indicated good specificity of the ScFv to bind EGFRvIII. An immune phage ScFv library is successfully constructed, and the ScFv antibody fragment is capable of specific binding to EGFRvIII.

  5. Completing the cervical screening pathway: Factors that facilitate the increase of self-collection uptake among under-screened and never-screened women, an Australian pilot study.

    Science.gov (United States)

    McLachlan, E; Anderson, S; Hawkes, D; Saville, M; Arabena, K

    2018-02-01

    To examine factors that enhance under-screened and never-screened women's completion of the self-collection alternative pathway of the Renewed National Cervical Screening Program (ncsp) in Victoria, Australia. With the Australian ncsp changing, starting on 1 December 2017, the Medical Services Advisory Committee (msac) recommended implementing human papillomavirus (hpv) testing using a self-collected sample for under-screened and never-screened populations. In response, a multi-agency group implemented an hpv self-collection pilot project to trial self-collection screening pathways for eligible women. Quantitative data were collected on participation rates and compliance rates with follow-up procedures across three primary health care settings. Forty women who self-collected were interviewed in a semi-structured format, and seven agency staff completed in-depth interviews. Qualitative data were used to identify and understand clinical and personal enablers that assisted women to complete self-collection cervical screening pathways successfully. Eighty-five per cent (10 women) of participants who tested positive for hpv successfully received their results and completed follow-up procedures as required. Two remaining participants also received hpv-positive results. However, agencies were unable to engage them in follow-up services and procedures. The overall participation rate in screening (self-collection or Pap test) was 85.7% (84 women), with 79 women self-collecting. Qualitative data indicated that clear explanations on self-collection, development of trusting, empathetic relationships with health professionals, and recognition of participants' past experiences were critical to the successful completion of the self-collection pathway. When asked about possible inhibitors to screening and to following up on results and appointments, women cited poor physical and mental health, as well as financial and other structural barriers. A well-implemented process, led by

  6. Breast cancer screening implementation and reassurance

    DEFF Research Database (Denmark)

    Østerø, J; Siersma, Volkert Dirk; Brodersen, John

    2013-01-01

    difference in reported psychosocial aspects had disappeared or been reduced because of the nationwide screening implementation. METHODS: The 1000 women included in the previous survey were posted part I of the questionnaire Consequences of Screening in Breast Cancer (COS-BC1) in August 2011, nearly 5 years......BACKGROUND: Women not offered screening mammography reported higher levels of negative psychosocial aspects than women offered screening. This was demonstrated in a questionnaire survey where 1000 women were included: 500 women living in areas where the public authorities had never offered...... screening mammography and 500 women living in areas where women had been invited to screening mammography for >10 years. After this baseline survey, nationwide screening mammography was implemented. The aim of this follow-up study was to resurvey the 1000 women and to investigate if the identified...

  7. A generic approach for expanding homolog-targeted residue screening of sulfonamides using a fast matrix separation and class-specific fragmentation-dependent acquisition with a hybrid quadrupole-linear ion trap mass spectrometer

    International Nuclear Information System (INIS)

    Huang Chunlin; Guo Bin; Wang Xiaoying; Li Jie; Zhu Weitao; Chen Bo; Ouyang Shan; Yao Shouzhuo

    2012-01-01

    Highlights: ► Generic homolog-targeted screening approach for multi-residual sulfonamide analogs. ► Single-tube extraction/partitioning-multifunction adsorption cleanup for direct injection. ► Class-specific fragmentation for expanding coverage of N 4 -acetyl and N-OH metabolites. ► PreS–IDA–EPI in LC–QqLIT for simultaneous screening and confirmation of real samples. - Abstract: A generic and efficient homolog-targeted approach was used to expand screening and detection of target class of sulfonamides and structural analogs, based on a fast single-tube extraction/partitioning-multifunction adsorption cleanup (SEP/MAC) for class-specific fragmentation-dependent acquisition with a liquid chromatography–hybrid triple-quadrupole linear ion trap mass spectrometer (LC–QqLIT). By combining the two-stage process conducted in a single tube as one-pot protocol, the straightforward SEP/MAC procedure was optimized to offer clean extracts with reasonable recovery (71–109% with RSDs 4 -acetyl and hydroxylamine metabolites plus their possible dimers. Moreover, the PreS-triggered automatically enhanced product ion spectral acquisition enabled simultaneous screening, profiling and confirmation of an unlimited number of analytes belonging to the sulfonamide class within a single analysis. The validation and application results of the generic SEP/MAC-based LC–QqLIT strategy consistently demonstrated favorable performances with acceptable accuracy (67–116%), precision (RSDs −1 ) to meet the acceptance criteria for all the sulfonamide–tissue combinations. Thus, the integration of the matrix-independent SEP/MAC procedure and the multiparameter matching algorithm with the unit-resolution LC–QqLIT instrument can serve as a valuable semi-targeted discovery strategy for rapid screening and reliable quantitative/confirmatory analysis of real samples.

  8. ScreenBEAM: a novel meta-analysis algorithm for functional genomics screens via Bayesian hierarchical modeling.

    Science.gov (United States)

    Yu, Jiyang; Silva, Jose; Califano, Andrea

    2016-01-15

    Functional genomics (FG) screens, using RNAi or CRISPR technology, have become a standard tool for systematic, genome-wide loss-of-function studies for therapeutic target discovery. As in many large-scale assays, however, off-target effects, variable reagents' potency and experimental noise must be accounted for appropriately control for false positives. Indeed, rigorous statistical analysis of high-throughput FG screening data remains challenging, particularly when integrative analyses are used to combine multiple sh/sgRNAs targeting the same gene in the library. We use large RNAi and CRISPR repositories that are publicly available to evaluate a novel meta-analysis approach for FG screens via Bayesian hierarchical modeling, Screening Bayesian Evaluation and Analysis Method (ScreenBEAM). Results from our analysis show that the proposed strategy, which seamlessly combines all available data, robustly outperforms classical algorithms developed for microarray data sets as well as recent approaches designed for next generation sequencing technologies. Remarkably, the ScreenBEAM algorithm works well even when the quality of FG screens is relatively low, which accounts for about 80-95% of the public datasets. R package and source code are available at: https://github.com/jyyu/ScreenBEAM. ac2248@columbia.edu, jose.silva@mssm.edu, yujiyang@gmail.com Supplementary data are available at Bioinformatics online. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  9. Nutrition screening: science behind simplicity

    African Journals Online (AJOL)

    Nutrition screening triggers entry into the nutrition care process.1 Screening has informally been described as simple, quick or low-intensity proxy for more complex procedures. More formal definitions for the nutrition setting have been proposed, describing nutrition screening as a process of identifying patients, clients, or ...

  10. Push for the Second Screen

    DEFF Research Database (Denmark)

    Sørensen, Jannick Kirk; Sørensen, Lene Tolstrup

    Users’ perception of the relation between the TV screen and a secondary screen (e.g. smartphone or tablet) is examined empirically in a pilot project through a low-fi prototype and interviews. Early observations indicate that the user value/acceptance of push-messages delivered to the second screen...

  11. Advances in cervical screening technology.

    Science.gov (United States)

    Stoler, M H

    2000-03-01

    The Pap smear unquestionably is a successful screening test for cervical cancer. However, recent advances in technology have raised questions regarding whether the conventional Pap smear is still the standard of care. This article relates issues of screening and cost-effectiveness to the state of the art in thin layer preparations, cytology automation, human papillomavirus screening, human papillomavirus vaccines, and other cervical screening adjuncts. Perhaps nowhere in medicine is clinical decision making being more strongly influenced by market and other external forces than in cervical cytopathology.

  12. Predictors of adherence to screening guidelines for chronic diseases of lifestyle, cancers, and HIV in a health-insured population in South Africa

    Directory of Open Access Journals (Sweden)

    Leegale Adonis

    2014-03-01

    Full Text Available Background: Adherence to screening guidelines has been widely accepted to reduce morbidity, mortality, and cost outcomes. The aim of this study was to identify predictors of adherence to screening guidelines for chronic diseases of lifestyle (CDL, cancers, and HIV in a health-insured population in South Africa, some of whom voluntarily opt into a wellness program that incentivizes screening. Method: A cross-sectional study for the period 2007–2011 was conducted using a random sample of 170,471 health insurance members from a single insurer. Adherence to screening guidelines was calculated from medical claims data. Results: Adherence to screening guidelines ranged from 1.1% for colorectal cancer to 40.9% for cholesterol screening. Members of the wellness program were up to three times more likely to screen for diseases (odds ratio [OR]=3.2 for HIV screening, confidence interval [CI]=2.75–3.73. Plan type (full comprehensive plan was most strongly associated with cholesterol screening (OR=3.53, CI=3.27–3.80, and most negatively associated (hospital-only core plan with cervical cancer screening (OR= 0.44, CI=0.28–0.70. Gender was a negative predictor for glucose screening (OR=0.88, CI=0.82–0.96. Provincial residence was most strongly associated with cervical cancer screening (OR=1.89, CI=0.65–5.54. Conclusion: Adherence to screening recommendations was <50%. Plan type, gender, provincial residence, and belonging to an incentivized wellness program were associated with disproportionate utilization of screening services, even with equal payment access.

  13. Physics in Screening Environments

    Science.gov (United States)

    Certik, Ondrej

    In the current study, we investigated atoms in screening environments like plasmas. It is common practice to extract physical data, such as temperature and electron densities, from plasma experiments. We present results that address inherent computational difficulties that arise when the screening approach is extended to include the interaction between the atomic electrons. We show that there may arise an ambiguity in the interpretation of physical properties, such as temperature and charge density, from experimental data due to the opposing effects of electron-nucleus screening and electron-electron screening. The focus of the work, however, is on the resolution of inherent computational challenges that appear in the computation of two-particle matrix elements. Those enter already at the Hartree-Fock level. Furthermore, as examples of post Hartree-Fock calculations, we show second-order Green's function results and many body perturbation theory results of second order. A self-contained derivation of all necessary equations has been included. The accuracy of the implementation of the method is established by comparing standard unscreened results for various atoms and molecules against literature for Hartree-Fock as well as Green's function and many body perturbation theory. The main results of the thesis are presented in the chapter called Screened Results, where the behavior of several atomic systems depending on electron-electron and electron-nucleus Debye screening was studied. The computer code that we have developed has been made available for anybody to use. Finally, we present and discuss results obtained for screened interactions. We also examine thoroughly the computational details of the calculations and particular implementations of the method.

  14. Abdominal aortic aneurysm screening program in Poland.

    Science.gov (United States)

    Jawien, A; Formankiewicz, B; Derezinski, T; Migdalski, A; Brazis, P; Woda, L

    Screening for abdominal aortic aneurysms (AAA) is currently recommended by several vascular societies. In countries where it has been introduced the prevalence of AAAs differed greatly and was mainly related to cigarette smoking. The screening program also had an enormous impact on the decrease of AAA ruptures and reduced mortality rate. These facts have led to the introduction of the first screening program for AAAs in Poland. The aim of the study was to determine the prevalence of AAAs among men aged 60 years and older undergoing ultrasound examination of the abdominal aorta. A single ultrasonography of the abdomen was performed to assess the aorta from the renal arteries to the bifurcation and the diameter of the aorta was measured at its widest point. The cut-off value for determining an aortic aneurysm was set at a diameter of ≥ 30 mm. All ultrasonography measurements were performed by physicians in outpatient departments throughout the Kuyavian-Pomeranian Province. Additionally, each subject had to fill out a questionnaire with demographic data, smoking habits, existing comorbidities and familial occurrence of AAAs. The study was conducted from October 2009 to November 2011. The abdominal aorta ultrasound examinations were carried out in 1556 men aged 60 years and older. The prevalence of AAA in the study population was 6.0 % (94 out of 1556). The average age of the men was 69 years (SD 6 years, range 60-92 years). In the study population 55 % of the men smoked or had smoked and 3 % were aware of the presence of AAAs in family members. There were three risk factors significantly associated with the presence of AAAs: age (p < 0.05), smoking (72.3 % vs 53.9 %, p = 0.004) and family history of AAAs (9.6 % vs 2.7 %, p = 0.017). The prevalence of AAAs among men in Poland is higher than in other European countries and the USA. The screening program for AAAs is an easy and reliable method for detecting early stages of the disease and

  15. Comparison of UK and US screening criteria for detection of retinopathy of prematurity in a developing nation.

    Science.gov (United States)

    Ugurbas, Silay Canturk; Gulcan, Hande; Canan, Handan; Ankarali, Handan; Torer, Birgin; Akova, Yonca Aydın

    2010-12-01

    To determine the incidence, risk factors, and appropriateness of differing guidelines in developed nations for screening for retinopathy of prematurity (ROP) in a single nursery in a large urban city in southern Turkey. The records of 260 premature infants born ≤34 weeks in a single tertiary unit were retrospectively reviewed for ROP risk factors and diagnosis. Applicability of UK and US criteria were assessed by the use of receiver operating characteristic curves. ROP of any stage was present in 60 infants (23%); ROP requiring treatment was seen in 30 (11.5%). Univariate analysis showed a significant relationship among the following factors: gestational age, birth weight, total duration of supplemental oxygen, duration of mechanical ventilation, respiratory distress syndrome, anemia, and intraventricular hemorrhage (p < 0.0001). Multiple logistic regression analysis showed gestational age (p = 0.039), birth weight (p = 0.05), respiratory distress syndrome (p = 0.05), and anemia (p = 0.004) as independent predictors of ROP requiring treatment. Area under curve for gestational age alone for diagnosing stage 2 or greater ROP was 0.824 ± 0.03 (p = 0.0001) and for birth weight alone was 0.808 ± 0.03 (p = 0.0001). UK screening criteria detected all stage 2 and greater ROP; US screening criteria missed 2 infants with stage 2 ROP but detected all treatment-requiring disease. Adoption of these screening criteria would have reduced unnecessary examinations by either 21% (UK) or 37% (US). UK and US criteria improved the detection accuracy for ROP requiring treatment in Turkey and should be studied for other developing nations. Copyright © 2010 American Association for Pediatric Ophthalmology and Strabismus. Published by Mosby, Inc. All rights reserved.

  16. Luminescent screens

    International Nuclear Information System (INIS)

    Lu, C.-I.

    1982-01-01

    Luminescent screens which are useful for such purposes as intensifying screens for radiographs are comprised of a support bearing a layer of finely divided particles of a phosphor dispersed in a cross-linked polymeric matrix formed by heat-curing of a coating composition comprising an unsaturated cross-linkable polymer, a polymerizable acrylic monomer, a thermoplastic polyurethane elastomer, and a heat-activatable polymerization initiator. The phosphor layer includes voids formed by evaporation of an evaporable component which is present in the coating composition from which such layer is formed. (author)

  17. Measuring lip force by oral screens Part 2: The importance of screen design, instruction and suction.

    Science.gov (United States)

    Wertsén, Madeleine; Stenberg, Manne

    2017-10-01

    The aim of this study was to find a reliable method for measuring lip force and to find the most important factors that influence the measurements in terms of magnitude and variability. The hypothesis tested was that suction is involved and thus the instruction and the design of the oral screen are of importance when measuring lip force. This is a methodological study in a healthy population. This study was conducted in a general community. The designs of the screens were soft and hard prefabricated screens and 2 semi-individually made with a tube allowing air to pass. The screens and the instructions squeeze or suck were tested on 29 healthy adults, one at a time and on 4 occasions. The test order of the screens was randomized. Data were collected during 4 consecutive days, and the procedure was repeated after 1 month. The participants were 29 healthy adult volunteers. The instruction was an important mean to distinguish between squeezing and sucking. The design of the screen affected the lip force so that it increases in relation to the projected area of the screen. A screen design with a tube allowing air to pass made it possible to avoid suction when squeezing. By measuring with and without allowing air to pass, it was possible to distinguish between suction related and not suction related lip force. The additional screen pressure when sucking was related to the ability to produce a negative intraoral pressure. In conclusion lip force increases in relation to the projected area of the screen, sucking generally increases the measured lip force and the additional screen pressure when sucking is related to the ability to produce a negative intraoral pressure.

  18. Using lessons from breast, cervical, and colorectal cancer screening to inform the development of lung cancer screening programs.

    Science.gov (United States)

    Armstrong, Katrina; Kim, Jane J; Halm, Ethan A; Ballard, Rachel M; Schnall, Mitchell D

    2016-05-01

    Multiple advisory groups now recommend that high-risk smokers be screened for lung cancer by low-dose computed tomography. Given that the development of lung cancer screening programs will face many of the same issues that have challenged other cancer screening programs, the National Cancer Institute-funded Population-based Research Optimizing Screening through Personalized Regimens (PROSPR) consortium was used to identify lessons learned from the implementation of breast, cervical, and colorectal cancer screening that should inform the introduction of lung cancer screening. These lessons include the importance of developing systems for identifying and recruiting eligible individuals in primary care, ensuring that screening centers are qualified and performance is monitored, creating clear communication standards for reporting screening results to referring physicians and patients, ensuring follow-up is available for individuals with abnormal test results, avoiding overscreening, remembering primary prevention, and leveraging advances in cancer genetics and immunology. Overall, this experience emphasizes that effective cancer screening is a multistep activity that requires robust strategies to initiate, report, follow up, and track each step as well as a dynamic and ongoing oversight process to revise current screening practices as new evidence regarding screening is created, new screening technologies are developed, new biological markers are identified, and new approaches to health care delivery are disseminated. Cancer 2016;122:1338-1342. © 2016 American Cancer Society. © 2016 American Cancer Society.

  19. Effect of a Low-Intensity PSA-Based Screening Intervention on Prostate Cancer Mortality: The CAP Randomized Clinical Trial.

    Science.gov (United States)

    Martin, Richard M; Donovan, Jenny L; Turner, Emma L; Metcalfe, Chris; Young, Grace J; Walsh, Eleanor I; Lane, J Athene; Noble, Sian; Oliver, Steven E; Evans, Simon; Sterne, Jonathan A C; Holding, Peter; Ben-Shlomo, Yoav; Brindle, Peter; Williams, Naomi J; Hill, Elizabeth M; Ng, Siaw Yein; Toole, Jessica; Tazewell, Marta K; Hughes, Laura J; Davies, Charlotte F; Thorn, Joanna C; Down, Elizabeth; Davey Smith, George; Neal, David E; Hamdy, Freddie C

    2018-03-06

    Prostate cancer screening remains controversial because potential mortality or quality-of-life benefits may be outweighed by harms from overdetection and overtreatment. To evaluate the effect of a single prostate-specific antigen (PSA) screening intervention and standardized diagnostic pathway on prostate cancer-specific mortality. The Cluster Randomized Trial of PSA Testing for Prostate Cancer (CAP) included 419 582 men aged 50 to 69 years and was conducted at 573 primary care practices across the United Kingdom. Randomization and recruitment of the practices occurred between 2001 and 2009; patient follow-up ended on March 31, 2016. An invitation to attend a PSA testing clinic and receive a single PSA test vs standard (unscreened) practice. Primary outcome: prostate cancer-specific mortality at a median follow-up of 10 years. Prespecified secondary outcomes: diagnostic cancer stage and Gleason grade (range, 2-10; higher scores indicate a poorer prognosis) of prostate cancers identified, all-cause mortality, and an instrumental variable analysis estimating the causal effect of attending the PSA screening clinic. Among 415 357 randomized men (mean [SD] age, 59.0 [5.6] years), 189 386 in the intervention group and 219 439 in the control group were included in the analysis (n = 408 825; 98%). In the intervention group, 75 707 (40%) attended the PSA testing clinic and 67 313 (36%) underwent PSA testing. Of 64 436 with a valid PSA test result, 6857 (11%) had a PSA level between 3 ng/mL and 19.9 ng/mL, of whom 5850 (85%) had a prostate biopsy. After a median follow-up of 10 years, 549 (0.30 per 1000 person-years) died of prostate cancer in the intervention group vs 647 (0.31 per 1000 person-years) in the control group (rate difference, -0.013 per 1000 person-years [95% CI, -0.047 to 0.022]; rate ratio [RR], 0.96 [95% CI, 0.85 to 1.08]; P = .50). The number diagnosed with prostate cancer was higher in the intervention group (n = 8054; 4

  20. Thumb Reach of Indonesian Young Adult When Interacting with Touchscreen of Single-Handed Device: A Preliminary Study

    Science.gov (United States)

    Umami, M. K.

    2018-01-01

    This study is a preliminary survey on thumb reach of Indonesian population when interacting with single-handed device. This study was aimed to know the thumb reach envelope on the screen of mobile phone. The correlation between the thumb reach vs. the hand length and thumb length was also identified. Thirty young adults participated in the study. All participants had normal body stature and were right-handed person. In the observational phase, the participant was asked to colour the canvas area on the screen of the mobile phone by using his/her thumb. The participant had to complete the task by applying the single hand interaction. The participant should grab the mobile phone as he/she use it normally in his/her daily activities. The thumb reach envelope of participants was identified from the coloured area of the canvas. The results of this study found that participants with a large hand length and thumb length tend to have a large thumb reach. The results of this study also show the thumb reach area of the participants is forming an elliptical shape that runs from the northeast to southwest on the device screen.

  1. How is adults’ screen time behaviour influencing their views on screen time restrictions for children? A cross-sectional study

    Directory of Open Access Journals (Sweden)

    Stephanie Schoeppe

    2016-03-01

    Full Text Available Abstract Background High screen time in children and its detrimental health effects is a major public health problem. How much screen time adults think is appropriate for children remains little explored, as well as whether adults’ screen time behaviour would determine their views on screen time restrictions for children. This study aimed to investigate how adults’ screen time behaviour influences their views on screen time restrictions for children, including differences by gender and parental status. Methods In 2013, 2034 Australian adults participated in an online survey conducted by the Population Research Laboratory at Central Queensland University, Rockhampton. Adult screen time behaviour was assessed using the Workforce Sitting Questionnaire. Adults reported the maximum time children aged between 5–12 years should be allowed to spend watching TV and using a computer. Ordinal logistic regression was used to compare adult screen time behaviour with views on screen time restrictions for children. Results Most adults (68 % held the view that children should be allowed no more than 2 h of TV viewing and computer use on school days, whilst fewer adults (44 % thought this screen time limit is needed on weekend days. Women would impose higher screen time restrictions for children than men (p  2 h on watching TV and using the computer at home on work days (66 % and non-work days (88 %. Adults spending ≤ 2 h/day in leisure-related screen time were less likely to permit children > 2 h/day of screen time. These associations did not differ by adult gender and parental status. Conclusions Most adults think it is appropriate to limit children’s screen time to the recommended ≤ 2 h/day but few adults themselves adhere to this screen time limit. Adults with lower screen use may be more inclined to limit children’s screen time. Strategies to reduce screen time in children may also need to target adult screen use.

  2. Depression screening using the Patient Health Questionnaire-9 administered on a touch screen computer.

    Science.gov (United States)

    Fann, Jesse R; Berry, Donna L; Wolpin, Seth; Austin-Seymour, Mary; Bush, Nigel; Halpenny, Barbara; Lober, William B; McCorkle, Ruth

    2009-01-01

    To (1) evaluate the feasibility of touch screen depression screening in cancer patients using the Patient Health Questionnaire-9 (PHQ-9), (2) evaluate the construct validity of the PHQ-9 using the touch screen modality, and (3) examine the prevalence and severity of depression using this screening modality. The PHQ-9 was placed in a web-based survey within a study of the clinical impact of computerized symptom and quality of life screening. Patients in medical oncology, radiation oncology, and hematopoietic stem cell transplantation (HSCT) clinics used the program on a touch screen computer in waiting rooms prior to therapy (T1) and during therapy (T2). Responses of depressed mood or anhedonia (PHQ-2 cardinal depression symptoms) triggered additional items. PHQ-9 scores were provided to the oncology team in real time. Among 342 patients enrolled, 33 (9.6%) at T1 and 69 (20.2%) at T2 triggered the full PHQ-9 by endorsing at least one cardinal symptom. Feasibility was high, with at least 97% completing the PHQ-2 and at least 96% completing the PHQ-9 when triggered and a mean completion time of about 2 min. The PHQ-9 had good construct validity. Medical oncology patients had the highest percent of positive screens (12.9%) at T1, while HSCT patients had the highest percent (30.5%) at T2. Using this method, 21 (6.1%) at T1 and 54 (15.8%) at T2 of the total sample had moderate to severe depression. The PHQ-9 administered on a touch screen computer is feasible and provides valid depression data in a diverse cancer population. (c) 2008 John Wiley & Sons, Ltd.

  3. Patient-initiated breast cancer screening

    International Nuclear Information System (INIS)

    Chilcote, W.

    1990-01-01

    This paper reviews the results of a breast cancer screening program sponsored by organizations at workplace or community locations. A comprehensive mobile breast cancer screening program, including education, breast physical examination, and mammography, was provided to 89 local organizations at $50.00 per examination over an 18-month period. The examination was patient initiated, following the ACS screening guidelines. Estimates of eligible women were provided by each organization. A total of 5,030 women at 89 organizations were screened for breast cancer. Approximately 25,727 women were eligible

  4. Modeling and Design of High-Efficiency Single-Photon Sources

    DEFF Research Database (Denmark)

    Gregersen, Niels; Nielsen, Per Kær; Mørk, Jesper

    2013-01-01

    be electrically driven. Several design strategies addressing these requirements have been proposed. In the cavity-based source, light emission is controlled using resonant cavity quantum electrodynamics effects, whereas in the waveguide-based source, broadband electric field screening effects are employed......Solid-state sources capable of emitting single photons on demand are of great interest in quantum information applications. Ideally, such a source should emit exactly one photon into the collection optics per trigger, the emitted photons should be indistinguishable, and the source should...

  5. Liver (Hepatocellular) Cancer Screening

    Science.gov (United States)

    ... Treatment Liver Cancer Prevention Liver Cancer Screening Research Liver (Hepatocellular) Cancer Screening (PDQ®)–Patient Version What is ... These are called diagnostic tests . General Information About Liver (Hepatocellular) Cancer Key Points Liver cancer is a ...

  6. Hearing Loss: Screening Newborns

    Science.gov (United States)

    ... of this page please turn JavaScript on. Feature: Hearing Loss Screening Newborns Past Issues / Spring 2015 Table ... deafness, which account for most cases. Screening Newborns' Hearing Now Standard In 1993, children born in the ...

  7. Systematic immunohistochemical screening for Lynch syndrome in colorectal cancer: a single centre experience of 486 patients.

    Science.gov (United States)

    Zumstein, Valentin; Vinzens, Fabrizio; Zettl, Andreas; Heinimann, Karl; Koeberle, Dieter; von Flüe, Markus; Bolli, Martin

    2016-01-01

    Germline mutations in DNA mismatch repair (MMR) genes MLH1, MSH2, MSH6 and PMS2 cause autosomal dominantly inherited Lynch syndrome. Lynch syndrome patients and their families benefit from life-saving intensive cancer surveillance. Approximately one in 30 colorectal cancers arises in the setting of Lynch syndrome. The aim of this study was to assess the detection rate of Lynch syndrome at our institution after introduction of systematic immunohistochemical screening for MMR deficiency in colorectal cancers from 2011 to 2015. Following the recommendations by the Evaluation of Genomic Applications in Practice and Prevention working group all colorectal cancers were immunohistochemically stained for the presence of MMR proteins MLH1, PMS2, MSH2 and MSH6, independent of clinical criteria. In the case of loss of MLH1, the somatic BRAF mutation V600E was assessed with molecular testing and/or immunohistochemistry. Clinical follow-up of potential Lynch syndrome carriers (patients with tumours showing loss of MLH1 expression with absence of BRAFV600E, loss of PMS2, MSH2 or MSH6) was evaluated. Of all patients (n = 486), loss of MMR protein expression was found in 73 (15.0%) tumours. Twenty-eight (6.0%) were classified as potential Lynch syndrome carriers. Of the genetically tested potential Lynch syndrome carriers (10 out of 28 patients), 40% were first diagnosed with Lynch syndrome. Implementation of systematic immunohistochemistry screening for Lynch syndrome showed that 6% of colorectal cancers were potentially Lynch-syndrome related. Tumour board protocols should systematically contain information on MMR status of all colorectal cancers and, in MMR deficient cases, include clear recommendations for genetic counselling for all potential Lynch syndrome patients.

  8. Screening for type 2 diabetes: a short report for the National Screening Committee.

    Science.gov (United States)

    Waugh, N R; Shyangdan, D; Taylor-Phillips, S; Suri, G; Hall, B

    2013-08-01

    The prevalence of type 2 diabetes mellitus (T2DM) has been increasing, owing to increases in overweight and obesity, decreasing physical activity and the changing demographic structure of the population. People can develop T2DM without symptoms and up to 20% may be undiagnosed. They may have diabetic complications, such as retinopathy, by the time they are diagnosed, or may suffer a heart attack, without warning. Undiagnosed diabetes can be detected by raised blood glucose levels. The aim of this review was to provide an update for the UK National Screening Committee (NSC) on screening for T2DM. As this review was undertaken to update a previous Health Technology Assessment review published in 2007, and a more recent Scottish Public Health Network review, searches for evidence were restricted from 2009 to end of January 2012, with selected later studies added. The databases searched were MEDLINE, EMBASE, MEDLINE-in-Process & Other Non-Indexed Citations, Science Citation Index and Conference Proceedings Citation Index. The case for screening was considered against the criteria used by the NSC to assess proposed population screening programmes. Population screening for T2DM does not meet all of the NSC criteria. Criterion 12, on optimisation of existing management, has not been met. A report by the National Audit Office (NAO) gives details of shortcomings. Criterion 13 requires evidence from high-quality randomised controlled trials that screening is beneficial. This has not been met. The Ely trial of screening showed no benefit. The ADDITION trial was not a trial of screening, but showed no benefit in cardiovascular outcomes from intensive management in people with screen-detected T2DM. Criterion 18 on staffing and facilities does not appear to have been met, according to the NAO report. Criterion 19 requires that all other options, including prevention, should have been considered. A large proportion of cases of T2DM could be prevented if people avoided becoming

  9. Screening for hypopituitarism in 509 patients with traumatic brain injury or subarachnoid hemorrhage.

    Science.gov (United States)

    Kopczak, Anna; Kilimann, Ingo; von Rosen, Friedrich; Krewer, Carmen; Schneider, Harald Jörn; Stalla, Günter Karl; Schneider, Manfred

    2014-01-01

    We performed a screening on patients with traumatic brain injury (TBI) or subarachnoid hemorrhage (SAH) to determine the prevalence of post-traumatic hypopituitarism in neurorehabilitation in a cross-sectional, observational single-center study. In addition, the therapeutic consequences of our screening were analyzed retrospectively. From February 2006 to August 2009, patients between 18 and 65 years (n=509) with the diagnosis of TBI (n=340) or SAH (n=169) were screened within two weeks of admittance to neurorehabilitation as clinical routine. Blood was drawn to determine fasting cortisol, free thyroxine (fT4), prolactin, testosterone or estradiol, and insulin-like growth factor I (IGF-I). Patients with abnormalities in the screening or clinical signs of hypopituitarism received further stimulation tests: growth hormone releasing hormone -L-arginine-test and adrenocorticotrophic hormone (ACTH)-test (n=36); ACTH-test alone (n=26); or insulin tolerance test (n=56). In our screening of 509 patients, 28.5% showed lowered values in at least one hormone of the hypothalamus-pituitary axis and 4.5% in two or more axes. The most common disturbance was a decrease of testosterone in 40.7% of all men (in the following 13/131 men were given substitution therapy). Low fT4 was detected in 5.9% (n=3 were given substitution therapy). Low IGF-I was detected in 5.8%, low cortisol in 1.4%, and low prolactin in 0.2%; none were given substitution therapy. Further stimulation tests revealed growth hormone deficiency in 20.7% (n=19/92) and hypocortisolism in 23.7% (n=28/118). Laboratory values possibly indicating hypopituitarism (33%) were common but did not always implicate post-traumatic hypopituitarism. Laboratory values possibly indicating hypopituitarism were common in our screening but most patients were clinically not diagnosed as pituitary insufficient and did not receive hormone replacement therapy. A routine screening of all patients in neurorehabilitation without considering

  10. Anodic Voltammetric determination of gemifloxacin using screen-printed carbon electrode

    Directory of Open Access Journals (Sweden)

    Abd-Elgawad Radi

    2013-04-01

    Full Text Available The electrochemical oxidation behavior and voltammetric assay of gemifloxacin were investigated using differential-pulse and cyclic voltammetry on a screen-printed carbon electrode. The effects of pH, scan rates, and concentration of the drug on the anodic peak current were studied. Voltammograms of gemifloxacin in Tris–HCl buffer (pH 7.0 exhibited a well-defined single oxidation peak. A differential-pulse voltammetric procedure for the quantitation of gemifloxacin has been developed and suitably validated with respect to linearity, limits of detection and quantification, accuracy, precision, specificity, and robustness. The calibration was linear from 0.5 to 10.0 μM, and the limits of detection and quantification were 0.15 and 5.0 μM. Recoveries ranging from 96.26% to 103.64% were obtained. The method was successfully applied to the determination of gemifloxacin in pharmaceutical tablets without any pre-treatment. Excipients present in the tablets did not interfere in the assay. Keywords: Screen-printed carbon electrode, Voltammetry, Gemifloxacin, Pharmaceutical analysis

  11. Development of a solar-powered residential air conditioner: Screening analysis

    Science.gov (United States)

    1975-01-01

    Screening analysis aimed at the definition of an optimum configuration of a Rankine cycle solar-powered air conditioner designed for residential application were conducted. Initial studies revealed that system performance and cost were extremely sensitive to condensing temperature and to the type of condenser used in the system. Consequently, the screening analyses were concerned with the generation of parametric design data for different condenser approaches; i. e., (1) an ambient air condenser, (2) a humidified ambient air condenser (3) an evaporative condenser, and (4) a water condenser (with a cooling tower). All systems feature a high performance turbocompressor and a single refrigerant (R-11) for the power and refrigeration loops. Data were obtained by computerized methods developed to permit system characterization over a broad range of operating and design conditions. The criteria used for comparison of the candidate system approaches were (1) overall system COP (refrigeration effect/solar heat input), (2) auxiliary electric power for fans and pumps, and (3) system installed cost or cost to the user.

  12. How many "Get Screened" messages does it take? Evidence from colorectal cancer screening promotion in the United States, 2012.

    Science.gov (United States)

    Cooper, Crystale Purvis; Gelb, Cynthia A; Hawkins, Nikki A

    2014-03-01

    Colorectal cancer screening has been widely promoted in the United States. We investigated the association between reported exposure to screening information during the past year and screening participation and knowledge. Data from the 2012 HealthStyles Fall survey of U.S. adults were examined using adjusted logistic regression to examine the frequency of exposure to screening information as a predictor of screening participation and knowledge; analyses were limited to participants aged ≥50years with no history of colorectal cancer or polyps (N=1714). Nearly half of the participants (44.9%) reported exposure to colorectal cancer screening information during the previous year. The most common sources of screening information were news reports, advertisements, and health care providers. Screening participation and knowledge consistently increased with the reported frequency of exposure to screening information, and these associations generally persisted when demographic variables were controlled. Compared with unexposed participants, significant gains in screening participation were associated with exposure to screening information 2-3 times (Adj. OR=1.84, p=0.001), 4-9 times (Adj. OR=2.00, p=0.001), and ≥10 times (Adj. OR=3.03, p<0.001) in the adjusted model. Increasing public exposure to screening promotion messages may augment screening participation and knowledge. Published by Elsevier Inc.

  13. Screening for coronary artery disease in respiratory patients: comparison of single- and dual-source CT in patients with a heart rate above 70 bpm

    International Nuclear Information System (INIS)

    Pansini, Vittorio; Remy-Jardin, Martine; Tacelli, Nunzia; Faivre, Jean-Baptiste; Remy, Jacques; Flohr, Thomas; Deken, Valerie; Duhamel, Alain

    2008-01-01

    To evaluate the assessibility of coronary arteries in respiratory patients with high heart rates. This study was based on the comparative analysis of two paired populations of 54 patients with a heart rate >70 bpm evaluated with dual-source (group 1) and single-source (group 2) CT. The mean heart rate was 89.1 bpm in group 1 and 86.7 bpm in group 2 (P=0.26). The mean number of assessable segments per patient was significantly higher in group 1 compared to group 2 (P≤0.0001). The proportions of patients in whom proximal and mid-coronary segments were assessable (i.e., the anatomical level enabling screening for asymptomatic coronary artery disease) were 35.3% for heart rates <110 bpm, 35.6% for heart rates <100 bpm, 40% for heart rates <90 bpm, and 60% for heart rates <80 bpm in group 1 and 11.3, 12.2, 8.8, and 10% for the corresponding thresholds in group 2 (P<0.05). In both groups of patients, coronary artery imaging was obtained from standard CT angiograms of the chest. The improvement in coronary imaging with dual-source CT suggests that high heart rates should no longer be considered as contraindications for ECG-gated CT angiograms of the chest whenever clinically relevant. (orig.)

  14. Evaluation of the potential benefit of computer-aided diagnosis (CAD) for lung cancer screening using photofluorography

    International Nuclear Information System (INIS)

    Matsumoto, Tsuneo; Nakamura, Hiroshi; Nakanishi, Takashi; Doi, Kunio; Kano, Akiko.

    1993-01-01

    To evaluate the potential benefit of computer-aided diagnosis (CAD) in lung cancer screenings using photofluorographic films, we performed an observer test with 12 radiologists. We used 60 photofluorographic films obtained from a lung cancer screening program in Yamaguchi Prefecture (30 contained cancerous nodules and 30 had no nodules). In these cases, our current automated detection scheme achieved a sensitivity of 80%, but yielded an average of 11 false-positives per image. The observer study consisted of three viewing conditions: 1) only the original image (single reading), 2) the original image and computer output obtained from the current CAD scheme (CAD 1), 3) the original image and computer output obtained from a simulated improved CAD scheme with the same 80% true-positive rate, but with an average of one false-positive per image (CAD 2). Compared with double reading using independent interpretations, which is based on a higher score between two single readings, CAD 2 was more sensitive in subtle cases. The specificity of CAD was superior to that of double reading. Although CAD 1 (Az=0.805) was inferior to double reading (Az=0.837) in terms of the ROC curve, CAD 2 (Az=0.872) significantly improved the ROC curve and also significantly reduced observation time (p<0.05). If the number of false positives can be reduced, computer-aided diagnosis may play an important role in lung cancer screening programs. (author)

  15. Onset timing, thoughts of self-harm, and diagnoses in postpartum women with screen-positive depression findings.

    Science.gov (United States)

    Wisner, Katherine L; Sit, Dorothy K Y; McShea, Mary C; Rizzo, David M; Zoretich, Rebecca A; Hughes, Carolyn L; Eng, Heather F; Luther, James F; Wisniewski, Stephen R; Costantino, Michelle L; Confer, Andrea L; Moses-Kolko, Eydie L; Famy, Christopher S; Hanusa, Barbara H

    2013-05-01

    The period prevalence of depression among women is 21.9% during the first postpartum year; however, questions remain about the value of screening for depression. To screen for depression in postpartum women and evaluate positive screen findings to determine the timing of episode onset, rate and intensity of self-harm ideation, and primary and secondary DSM-IV disorders to inform treatment and policy decisions. Sequential case series of women who recently gave birth. Urban academic women's hospital. During the maternity hospitalization, women were offered screening at 4 to 6 weeks post partum by telephone. Screen-positive women were invited to undergo psychiatric evaluations in their homes. A positive screen finding was an Edinburgh Postnatal Depression Scale (EPDS) score of 10 or higher. Self-harm ideation was assessed on EPDS item 10: "The thought of harming myself has occurred to me" (yes, quite often; sometimes; hardly ever; never). Screen-positive women underwent evaluation with the Structured Clinical Interview for DSM-IV for Axis I primary and secondary diagnoses. Ten thousand mothers underwent screening, with positive findings in 1396 (14.0%); of these, 826 (59.2%) completed the home visits and 147 (10.5%) completed a telephone diagnostic interview. Screen-positive women were more likely to be younger, African American, publicly insured, single, and less well educated. More episodes began post partum (40.1%), followed by during pregnancy (33.4%) and before pregnancy (26.5%). In this population, 19.3% had self-harm ideation. All mothers with the highest intensity of self-harm ideation were identified with the EPDS score of 10 or higher. The most common primary diagnoses were unipolar depressive disorders (68.5%), and almost two-thirds had comorbid anxiety disorders. A striking 22.6% had bipolar disorders. The most common diagnosis in screen-positive women was major depressive disorder with comorbid generalized anxiety disorder. Strategies to differentiate

  16. Onset Timing, Thoughts of Self-harm, and Diagnoses in Postpartum Women With Screen-Positive Depression Findings

    Science.gov (United States)

    Wisner, Katherine L.; Sit, Dorothy K. Y.; McShea, Mary C.; Rizzo, David M.; Zoretich, Rebecca A.; Hughes, Carolyn L.; Eng, Heather F.; Luther, James F.; Wisniewski, Stephen R.; Costantino, Michelle L.; Confer, Andrea L.; Moses-Kolko, Eyclie L.; Famy, Christopher S.; Hanusa, Barbara H.

    2015-01-01

    Importance The period prevalence of depression among women is 21.9% during the first postpartum year; however, questions remain about the value of screening for depression. Objectives To screen for depression in postpartum women and evaluate positive screen findings to determine the timing of episode onset, rate and intensity of self-harm ideation, and primary and secondary DSM-IV disorders to inform treatment and policy decisions. Design Sequential case series of women who recently gave birth. Setting Urban academic women’s hospital. Participants During the maternity hospitalization, women were offered screening at 4 to 6 weeks post parturn by telephone. Screen-positive women were invited to undergo psychiatric evaluations in their homes. Main Outcomes and Measures A positive screen finding was an Edinburgh Postnatal Depression Scale (EPDS) score of 10 or higher. Self-harm ideation was assessed on EPDS item 10: “The thought of harming myself has occurred to me” (yes, quite often; sometimes; hardly ever; never). Screen-positive women underwent evaluation with the Structured Clinical Interview for DSM-IV for Axis I primary and secondary diagnoses. Results Ten thousand mothers underwent screening, with positive findings in 1396 (14.0%); of these, 826 (59.2%) completed the home visits and 147 (10.5%) completed a telephone diagnostic interview. Screen-positive women were more likely to be younger, African American, publicly insured, single, and less well educated. More episodes began post partum (40.1%), followed by during pregnancy (33.4%) and before pregnancy (26.5%). In this population, 19.3% had self-harm ideation. All mothers with the highest intensity of self-harm ideation were identified with the EPDS score of 10 or higher. The most common primary diagnoses were unipolar depressive disorders (68.5%), and almost two-thirds had co-morbid anxiety disorders. A striking 22.6% had bipolar disorders. Conclusions and Relevance The most common diagnosis in screen

  17. Cervical cancer screening at crossroads

    DEFF Research Database (Denmark)

    Lynge, Elsebeth; Rygaard, Carsten; Baillet, Miguel Vazquez-Prada

    2014-01-01

    Cervical screening has been one of the most successful public health prevention programmes. For 50 years, cytology formed the basis for screening, and detected cervical intraepithelial lesions (CIN) were treated surgically to prevent progression to cancer. In a high-risk country as Denmark......, screening decreased the incidence of cervical cancer from 34 to 11 per 100,000, age-standardized rate (World Standard Population). Screening is, however, also expensive; Denmark (population: 5.6 million) undertakes close to half a million tests per year, and has 6-8 CIN-treated women for each prevented...... cancer case. The discovery of human papillomavirus (HPV) as the cause of cervical cancer dramatically changed perspectives for disease control. Screening with HPV testing was launched around 1990, and preventive HPV vaccination was licensed in 2006. Long-term randomized controlled trials (RCT...

  18. Single visit nonsurgical endodontic therapy for periapical cysts: A clinical study.

    Science.gov (United States)

    Maity, Ipsita; Meena, N; Kumari, R Anitha

    2014-04-01

    The aim of this study was to assess the outcome of single sitting root canal treatment (RCT) of asymptomatic teeth with periapical cysts. Ten maxillary anterior teeth showing periapical lesion on the radiograph was further screened by ultrasound with color power Doppler (CPD) for confirmation of a cyst. The average dimension of the lesions ranged from 1.3 to 1.9 cm. Single sitting RCT was performed on all the selected teeth. Postoperative healing was monitored at regular interval of 3 months, 6 months, and 1 year by using subjective feedback, radiograph, and ultrasound with CPD study. Eight among the ten cases showed either signs of complete healing or healing in progress by the end of 6-12 months. It was observed that single sitting nonsurgical endodontic management of asymptomatic teeth with periapical cyst confirmed by ultrasound was successful in selected cases.

  19. Differences in knowledge, attitudes, beliefs, and perceived risks regarding colorectal cancer screening among Chinese, Korean, and Vietnamese sub-groups.

    Science.gov (United States)

    Le, T Domi; Carney, Patricia A; Lee-Lin, Frances; Mori, Motomi; Chen, Zunqiu; Leung, Holden; Lau, Christine; Lieberman, David A

    2014-04-01

    Asian ethnic subgroups are often treated as a single demographic group in studies looking at cancer screening and health disparities. To evaluate knowledge and health beliefs associated with colorectal cancer (CRC) and CRC screening among Chinese, Korean, and Vietnamese subgroups, a survey assessed participants' demographic characteristics, healthcare utilization, knowledge, beliefs, attitudes associated with CRC and CRC screening. Exploratory factor analysis identified six factors accounting >60 % of the total variance in beliefs and attitudes. Cronbach's alpha coefficients assessed internal consistency. Differences among Asian subgroups were assessed using a Chi square, Fisher's exact, or Kruskal-Wallis test. Pearson's correlation coefficient assessed an association among factors. 654 participants enrolled: 238 Chinese, 217 Korean, and 199 Vietnamese. Statistically significant differences existed in demographic and health care provider characteristics, knowledge, and attitude/belief variables regarding CRC. These included knowledge of CRC screening modalities, reluctance to discuss cancer, belief that cancer is preventable by diet and lifestyle, and intention to undergo CRC screening. Chinese subjects were more likely to use Eastern medicine (52 % Chinese, 25 % Korean, 27 % Vietnamese; p Vietnamese; p Vietnamese subjects were less likely to consider CRC screening (95 % Chinese, 95 % Korean, 80 % Vietnamese; p < 0.0001). Important differences exist in knowledge, attitudes, and health beliefs among Asian subgroups. Understanding these differences will enable clinicians to deliver tailored, effective health messages to improve CRC screening and other health behaviors.

  20. An integrated PCR colony hybridization approach to screen cDNA libraries for full-length coding sequences.

    Science.gov (United States)

    Pollier, Jacob; González-Guzmán, Miguel; Ardiles-Diaz, Wilson; Geelen, Danny; Goossens, Alain

    2011-01-01

    cDNA-Amplified Fragment Length Polymorphism (cDNA-AFLP) is a commonly used technique for genome-wide expression analysis that does not require prior sequence knowledge. Typically, quantitative expression data and sequence information are obtained for a large number of differentially expressed gene tags. However, most of the gene tags do not correspond to full-length (FL) coding sequences, which is a prerequisite for subsequent functional analysis. A medium-throughput screening strategy, based on integration of polymerase chain reaction (PCR) and colony hybridization, was developed that allows in parallel screening of a cDNA library for FL clones corresponding to incomplete cDNAs. The method was applied to screen for the FL open reading frames of a selection of 163 cDNA-AFLP tags from three different medicinal plants, leading to the identification of 109 (67%) FL clones. Furthermore, the protocol allows for the use of multiple probes in a single hybridization event, thus significantly increasing the throughput when screening for rare transcripts. The presented strategy offers an efficient method for the conversion of incomplete expressed sequence tags (ESTs), such as cDNA-AFLP tags, to FL-coding sequences.