WorldWideScience

Sample records for single radio multi-channel

  1. Multi-Channel Distributed Coordinated Function over Single Radio in Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Kok-Keong (Jonathan Loo

    2011-01-01

    Full Text Available Multi-channel assignments are becoming the solution of choice to improve performance in single radio for wireless networks. Multi-channel allows wireless networks to assign different channels to different nodes in real-time transmission. In this paper, we propose a new approach, Multi-channel Distributed Coordinated Function (MC-DCF which takes advantage of multi-channel assignment. The backoff algorithm of the IEEE 802.11 distributed coordination function (DCF was modified to invoke channel switching, based on threshold criteria in order to improve the overall throughput for wireless sensor networks (WSNs over 802.11 networks. We presented simulation experiments in order to investigate the characteristics of multi-channel communication in wireless sensor networks using an NS2 platform. Nodes only use a single radio and perform channel switching only after specified threshold is reached. Single radio can only work on one channel at any given time. All nodes initiate constant bit rate streams towards the receiving nodes. In this work, we studied the impact of non-overlapping channels in the 2.4 frequency band on: constant bit rate (CBR streams, node density, source nodes sending data directly to sink and signal strength by varying distances between the sensor nodes and operating frequencies of the radios with different data rates. We showed that multi-channel enhancement using our proposed algorithm provides significant improvement in terms of throughput, packet delivery ratio and delay. This technique can be considered for WSNs future use in 802.11 networks especially when the IEEE 802.11n becomes popular thereby may prevent the 802.15.4 network from operating effectively in the 2.4 GHz frequency band.

  2. Multi-channel distributed coordinated function over single radio in wireless sensor networks.

    Science.gov (United States)

    Campbell, Carlene E-A; Loo, Kok-Keong Jonathan; Gemikonakli, Orhan; Khan, Shafiullah; Singh, Dhananjay

    2011-01-01

    Multi-channel assignments are becoming the solution of choice to improve performance in single radio for wireless networks. Multi-channel allows wireless networks to assign different channels to different nodes in real-time transmission. In this paper, we propose a new approach, Multi-channel Distributed Coordinated Function (MC-DCF) which takes advantage of multi-channel assignment. The backoff algorithm of the IEEE 802.11 distributed coordination function (DCF) was modified to invoke channel switching, based on threshold criteria in order to improve the overall throughput for wireless sensor networks (WSNs) over 802.11 networks. We presented simulation experiments in order to investigate the characteristics of multi-channel communication in wireless sensor networks using an NS2 platform. Nodes only use a single radio and perform channel switching only after specified threshold is reached. Single radio can only work on one channel at any given time. All nodes initiate constant bit rate streams towards the receiving nodes. In this work, we studied the impact of non-overlapping channels in the 2.4 frequency band on: constant bit rate (CBR) streams, node density, source nodes sending data directly to sink and signal strength by varying distances between the sensor nodes and operating frequencies of the radios with different data rates. We showed that multi-channel enhancement using our proposed algorithm provides significant improvement in terms of throughput, packet delivery ratio and delay. This technique can be considered for WSNs future use in 802.11 networks especially when the IEEE 802.11n becomes popular thereby may prevent the 802.15.4 network from operating effectively in the 2.4 GHz frequency band.

  3. Multi-channel software defined radio experimental evaluation and analysis

    CSIR Research Space (South Africa)

    Van der Merwe, JR

    2014-09-01

    Full Text Available Multi-channel software-defined radios (SDRs) can be utilised as inexpensive prototyping platforms for transceiver arrays. The application for multi-channel prototyping is discussed and measured results of coherent channels for both receiver...

  4. Decentralized power control for multi-radio multi-channel wireless mesh networks

    CSIR Research Space (South Africa)

    Olwal, TO

    2010-09-01

    Full Text Available Multi-Radio Multi-Channel (MRMC) WMNs result in power control problems including interference, un-scalable connectivity and energy consumption. Several previous studies have focused on the single radio wireless configurations while studying power...

  5. Throughput Improvement in Multi radio Multi channel Wireless Cognitive Radio Mesh Networks

    Directory of Open Access Journals (Sweden)

    Fahimeh Aghaei

    2016-10-01

    Full Text Available The classic spectrum management methods cannot efficiently supply the future multicast traffic demands. Recently, the cognitive radio technology has emerged as a promising solution to enhance the spectrum utilization. However, the potential heterogeneity in channel availability among the network users leads to send the packets through multiple channels. This significantly decreases the network throughput. The main goal of this paper is to reduce the multicast period in a single-cell and multi-channel wireless mesh cognitive radio network. In this regard, we jointly exploit the multicast scheduling policies, the intra-groups and inter-groups assistance strategies, and the Wireless Broadcast Advantage (WBA. Based on WBA, a single transmission of a node can simultaneously cover multiple neighboring receivers. In addition, by assigning multiple radios to each network user, we allow the nodes to simultaneously transmit/receive the packets on distinct channels. Numerical results of our comprehensive simulations demonstrate the efficiency of the proposed scheme in term of the network throughput.

  6. Multiple-state based power control for multi-radio multi-channel wireless mesh networks

    CSIR Research Space (South Africa)

    Olwal, TO

    2009-01-01

    Full Text Available Multi-Radio Multi-Channel (MRMC) systems are key to power control problems in wireless mesh networks (WMNs). In this paper, we present asynchronous multiple-state based power control for MRMC WMNs. First, WMN is represented as a set of disjoint...

  7. Autonomous transmission power adaptation for multi-radio multi-channel wireless mesh networks

    CSIR Research Space (South Africa)

    Olwal, TO

    2009-09-01

    Full Text Available Multi-Radio Multi-Channel (MRMC) systems are key to power control problems in WMNs. Previous studies have emphasized through- put maximization in such systems as the main design challenge and transmission power control treated as a secondary issue...

  8. Autonomous transmission power adaptation for multi-radio multi-channel wireless mesh networks

    CSIR Research Space (South Africa)

    Olwal, TO

    2008-09-01

    Full Text Available Multi-Radio Multi-Channel (MRMC) systems are key to power control problems in WMNs. Previous studies have emphasized throughput maximization in such systems as the main design challenge and transmission power control treated as a secondary issue...

  9. Stochastic geometry model for multi-channel fog radio access networks

    KAUST Repository

    Emara, Mostafa

    2017-06-29

    Cache-enabled base station (BS) densification, denoted as a fog radio access network (F-RAN), is foreseen as a key component of 5G cellular networks. F-RAN enables storing popular files at the network edge (i.e., BS caches), which empowers local communication and alleviates traffic congestions at the core/backhaul network. The hitting probability, which is the probability of successfully transmitting popular files request from the network edge, is a fundamental key performance indicator (KPI) for F-RAN. This paper develops a scheduling aware mathematical framework, based on stochastic geometry, to characterize the hitting probability of F-RAN in a multi-channel environment. To this end, we assess and compare the performance of two caching distribution schemes, namely, uniform caching and Zipf caching. The numerical results show that the commonly used single channel environment leads to pessimistic assessment for the hitting probability of F-RAN. Furthermore, the numerical results manifest the superiority of the Zipf caching scheme and quantify the hitting probability gains in terms of the number of channels and cache size.

  10. Interference-aware power control for multi-radio multi-channel wireless mesh networks

    CSIR Research Space (South Africa)

    Olwal, TO

    2009-09-01

    Full Text Available shocks term ( )I tε is a random variable with zero mean and variance, 2εσ . Assume that corresponding to a UCG l is the user (NIC- pair) i. Then, the multi-radio multi-channel state interaction (MRSI) model representation becomes [15...] ( ) ( ) ( ) ( ) 1 N y i ij j i j j i y t L t e t tε = ≠ = +∑ , (9) where ( )yi tε denotes the coordination process shocks with zero mean and covariance yεσ . ( )iC t is a unity...

  11. Tunable single-photon multi-channel quantum router based on an optomechanical system

    Science.gov (United States)

    Ma, Peng-Cheng; Yan, Lei-Lei; Zhang, Jian; Chen, Gui-Bin; Li, Xiao-Wei; Zhan, You-Bang

    2018-01-01

    Routing of photons plays a key role in optical communication networks and quantum networks. Although the quantum routing of signals has been investigated for various systems, both in theory and experiment, the general form of a quantum router with multi-output terminals still needs to be explored. Here, we propose an experimentally accessible tunable single-photon multi-channel routing scheme using an optomechanics cavity which is Coulomb coupled to a nanomechanical resonator. The router can extract single photons from the coherent input signal and directly modulate them into three different output channels. More importantly, the two output signal frequencies can be selected by adjusting the Coulomb coupling strength. For application purposes, we justify that there is insignificant influence from the vacuum and thermal noises on the performance of the router under cryogenic conditions. Our proposal may pave a new avenue towards multi-channel routers and quantum networks.

  12. 4 × 160-Gbit/s multi-channel regeneration in a single fiber

    DEFF Research Database (Denmark)

    Wang, Ju; Ji, Hua; Hu, Hao

    2014-01-01

    Simultaneous regeneration of four high-speed (160 Gbit/s) wavelength-division multiplexed (WDM) and polarization-division multiplexed (PDM) signals in a single highly nonlinear fiber (HNLF) is demonstrated. The regeneration operation is based on four-wave mixing in HNLF, where the degraded data...... phase modulation of the CW light. Mitigation of the inter-channel nonlinearities is achieved mainly through an inter-channel 0.5 bit slot time delay. Bidirectional propagation is also applied to relieve the inter-channel four-wave mixing. The multi-channel regeneration performance is validated by bit...

  13. Multi-Channel Adjustable DC Power Supply with Single Transformer Based on Spectral Separation

    Science.gov (United States)

    Benfeng, Zhang; Huafeng, Li; Sunan, Li

    2014-01-01

    To meet the need of multi-channel DC power supply to activate multiple macro fiber composite (MFC) material simultaneously, a novel multi-channel adjustable DC supply using single-input single-output transformer based on spectral separation is proposed. A hybrid signal containing multiple frequency bands is boosted to obtain a high-voltage signal without bands change. Several frequency selection circuits are then used to separate individual signals in different frequency band from the high-voltage signal. Finally, these signals are rectified and filtered respectively to obtain multiple channel DC voltages. The feasibility of the proposed scheme is analyzed theoretically and verified by simulation. The hybrid signal containing multiple frequency bands is constructed by MCU (Micro Control Unit) and boosted using push-pull boost circuit. Low-pass, band-pass and high-pass frequency selection circuits are used to obtain the individual high-voltage signal in different frequency bands, and the amplitude frequency response characteristics of these filters are simulated using PSpice. Experimental results prove that each part of the scheme runs reliable and the output is stable and adjustable.

  14. Self-aligned multi-channel superconducting nanowire single-photon detectors.

    Science.gov (United States)

    Cheng, Risheng; Guo, Xiang; Ma, Xiaosong; Fan, Linran; Fong, King Y; Poot, Menno; Tang, Hong X

    2016-11-28

    We describe a micromachining process to allow back-side coupling of an array of single-mode telecommunication fibers to individual superconducting nanowire single photon detectors (SNSPDs). This approach enables a back-illuminated detector structure which separates the optical access and electrical readout on two sides of the chip and thus allows for compact integration of multi-channel detectors. As proof of principle, we show the integration of four detectors on the same silicon chip with two different designs and their performances are compared. In the optimized design, the device shows saturated system detection efficiency of 16% while the dark count rate is less than 20 Hz, all achieved without the use of metal reflectors or distributed Bragg reflectors (DBRs). This back-illumination approach also eliminates the cross-talk between different detection channels.

  15. Performance analysis of correlated multi-channels in cognitive radio sensor network based smart grid

    CSIR Research Space (South Africa)

    Ogbodo, EU

    2017-09-01

    Full Text Available ) to dynamically allocate radio resources to the sensor nodes. However, one of the CRSN challenges is the problem of dual/multi correlation fading channels due to dual/multi antenna channels of the sensor nodes as well as very close spacing of sensor nodes...

  16. Wireless multi-channel single unit recording in freely moving and vocalizing primates.

    Science.gov (United States)

    Roy, Sabyasachi; Wang, Xiaoqin

    2012-01-15

    The ability to record well-isolated action potentials from individual neurons in naturally behaving animals is crucial for understanding neural mechanisms underlying natural behaviors. Traditional neurophysiology techniques, however, require the animal to be restrained which often restricts natural behavior. An example is the common marmoset (Callithrix jacchus), a highly vocal New World primate species, used in our laboratory to study the neural correlates of vocal production and sensory feedback. When restrained by traditional neurophysiological techniques marmoset vocal behavior is severely inhibited. Tethered recording systems, while proven effective in rodents pose limitations in arboreal animals such as the marmoset that typically roam in a three-dimensional environment. To overcome these obstacles, we have developed a wireless neural recording technique that is capable of collecting single-unit data from chronically implanted multi-electrodes in freely moving marmosets. A lightweight, low power and low noise wireless transmitter (headstage) is attached to a multi-electrode array placed in the premotor cortex of the marmoset. The wireless headstage is capable of transmitting 15 channels of neural data with signal-to-noise ratio (SNR) comparable to a tethered system. To minimize radio-frequency (RF) and electro-magnetic interference (EMI), the experiments were conducted within a custom designed RF/EMI and acoustically shielded chamber. The individual electrodes of the multi-electrode array were periodically advanced to densely sample the cortical layers. We recorded single-unit data over a period of several months from the frontal cortex of two marmosets. These recordings demonstrate the feasibility of using our wireless recording method to study single neuron activity in freely roaming primates. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. Multi-Channel Multi-Radio Using 802.11 Based Media Access for Sink Nodes in Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Kok-Keong Loo

    2011-05-01

    Full Text Available The next generation surveillance and multimedia systems will become increasingly deployed as wireless sensor networks in order to monitor parks, public places and for business usage. The convergence of data and telecommunication over IP-based networks has paved the way for wireless networks. Functions are becoming more intertwined by the compelling force of innovation and technology. For example, many closed-circuit TV premises surveillance systems now rely on transmitting their images and data over IP networks instead of standalone video circuits. These systems will increase their reliability in the future on wireless networks and on IEEE 802.11 networks. However, due to limited non-overlapping channels, delay, and congestion there will be problems at sink nodes. In this paper we provide necessary conditions to verify the feasibility of round robin technique in these networks at the sink nodes by using a technique to regulate multi-radio multichannel assignment. We demonstrate through simulations that dynamic channel assignment scheme using multi-radio, and multichannel configuration at a single sink node can perform close to optimal on the average while multiple sink node assignment also performs well. The methods proposed in this paper can be a valuable tool for network designers in planning network deployment and for optimizing different performance objectives.

  18. Multi-channel multi-radio using 802.11 based media access for sink nodes in wireless sensor networks.

    Science.gov (United States)

    Campbell, Carlene E-A; Khan, Shafiullah; Singh, Dhananjay; Loo, Kok-Keong

    2011-01-01

    The next generation surveillance and multimedia systems will become increasingly deployed as wireless sensor networks in order to monitor parks, public places and for business usage. The convergence of data and telecommunication over IP-based networks has paved the way for wireless networks. Functions are becoming more intertwined by the compelling force of innovation and technology. For example, many closed-circuit TV premises surveillance systems now rely on transmitting their images and data over IP networks instead of standalone video circuits. These systems will increase their reliability in the future on wireless networks and on IEEE 802.11 networks. However, due to limited non-overlapping channels, delay, and congestion there will be problems at sink nodes. In this paper we provide necessary conditions to verify the feasibility of round robin technique in these networks at the sink nodes by using a technique to regulate multi-radio multichannel assignment. We demonstrate through simulations that dynamic channel assignment scheme using multi-radio, and multichannel configuration at a single sink node can perform close to optimal on the average while multiple sink node assignment also performs well. The methods proposed in this paper can be a valuable tool for network designers in planning network deployment and for optimizing different performance objectives.

  19. Safety of multi-channel stimulation implants: a single blocking capacitor per channel is not sufficient after single-fault failure.

    Science.gov (United States)

    Nonclercq, Antoine; Lonys, Laurent; Vanhoestenberghe, Anne; Demosthenous, Andreas; Donaldson, Nick

    2012-04-01

    One reason given for placing capacitors in series with stimulation electrodes is that they prevent direct current flow and therefore tissue damage under fault conditions. We show that this is not true for multiplexed multi-channel stimulators with one capacitor per channel. A test bench of two stimulation channels, two stimulation tripoles and a saline bath was used to measure the direct current flowing through the electrodes under two different single fault conditions. The electrodes were passively discharged between stimulation pulses. For the particular condition used (16 mA, 1 ms stimulation pulse at 20 Hz with electrodes placed 5 cm apart), the current ranged from 38 to 326 μA depending on the type of fault. The variation of the fault current with time, stimulation amplitude, stimulation frequency and distance between the electrodes is given. Possible additional methods to improve safety are discussed.

  20. A new architecture for a single-chip multi-channel beamformer based on a standard FPGA

    DEFF Research Database (Denmark)

    Tomov, Borislav Gueorguiev; Jensen, Jørgen Arendt

    2001-01-01

    A new architecture for a compact medical ultrasound beamformer has been developed. Combination of novel and known principles has been utilized, leading to low processing power requirements and simple analog circuitry. Usage of a field programmable gate array (FPGA) for the digital signal processing...... provides programming flexibility. First, sparse sample processing is performed by generating the in-phase and quadrature beamformed signals. Hereby only 512 samples are beamformed for each line in an image. That leads to a 15-fold decrease in the number of operations and enables the use of Delta-Sigma (ΔΣ....... The control logic consists of few adders and counters and requires very limited resources. Fourth, the beamformer is fully programmable. Any channel can be set to use an arbitrary delay curve, and any number of these channels can be used together in an extendable modular multi-channel system. A prototype...

  1. Multi-Channel 40 Gbit/s NRZ-DPSK Demodulation Using a Single Silicon Microring Resonator

    DEFF Research Database (Denmark)

    Ding, Yunhong; Xu, Jing; Peucheret, Christophe

    2011-01-01

    We comprehensively analyze the demodulation of wavelength division multiplexed (WDM) non return-to-zero differential phase-shift keying (NRZ-DPSK) signals by a single microring resonator. Simultaneous demodulation of multiple 40 Gbit/s WDM NRZ-DPSK channels is demonstrated using a single silicon...

  2. Multi-channeled NbN superconducting single photon detectors (SSPDs) system with NbN meander nanowires

    International Nuclear Information System (INIS)

    Fujiwara, Mikio; Sasaki, Masahide; Miki, Shigehito; Wang Zhen

    2009-01-01

    A superconducting single photon detector (SSPD) is promising candidate of the detector in a quantum key distribution (QKD) system, because of its low dark count and high speed repetition rate. We have developed the SSPD system cooled by a GM cryocooler. In this system, and the work surface can be cooled 2.95 K and up to 6 SSPDs can be installed. The active areas of SSPDs are 10x10 μm 2 or 20x20 μm 2 , and the system detection efficiency at dark count rate of 100 Hz reached 2.6% at a wavelength of 1550 nm.

  3. Digital signal processing based multi channel analyzer

    International Nuclear Information System (INIS)

    Saklani, Vipin; Meenakshi Sundari, A.; Rai, A.K.; Sarma, C.V.R.

    2013-01-01

    Gamma Ray Spectrometry is an essential tool for mapping radio elemental concentrations and has found widespread applications in mineral exploration, geological mapping and environmental mapping. Spectrometry based on analog amplifiers with Gaussian pulse shaping has been used for more than 40 years. Digital electronics and digital signal processing methods have enhanced the spectrometer specifications. This paper presents the design and development of a FPGA based Gamma Ray Spectrometer featuring 1024 channel Multi Channel Analyser (MCA) with NaI(Tl) scintillation detector. The system shows significant improvements in energy resolution, count rate capability and dead time as compared to its analog counterpart. (author)

  4. A Multi-Channel Spectrum Sensing Fusion Mechanism for Cognitive Radio Networks: Design and Application to IEEE 802.22 WRANs

    OpenAIRE

    Tadayon, Navid; Aissa, Sonia

    2016-01-01

    The IEEE 802.22 is a new cognitive radio standard that is aimed at extending wireless outreach to rural areas. Known as wireless regional area networks, and designed based on the not-to-interfere spectrum sharing model, WRANs are channelized and centrally-controlled networks working on the under-utilized UHF/VHF TV bands to establish communication with remote users, so-called customer premises equipment (CPEs). Despite the importance of reliable and interference-free operation in these freque...

  5. Multi-channel Kondo necklace

    International Nuclear Information System (INIS)

    Fazekas, P.; Kee Haeyoung.

    1993-06-01

    A multi-channel generalization of Doniach's Kondo necklace model is formulated, and its phase diagram studied in the mean-field approximation. Our intention is to introduce the possible simplest model which displays some of the features expected from the overscreened Kondo lattice. The N conduction electron channels are represented by N sets of pseudospins τ J , j = 1 1,..., N which are all antiferromagnetically coupled to a periodic array of modul S = 1/2 spins. Exploiting permutation symmetry in the channel index j allows us to write down the self-consistency equation for general N. For N > 2, we find that the critical temperature is rising with increasing Kondo interaction; we interpret this effect by pointing out that the Kondo coupling creates the composite pseudospin objects which undergo an ordering transition. The relevance of our findings to the underlying fermionic multi-channel problem is discussed. (author). 33 refs, 1 fig

  6. Digital Multi Channel Analyzer Enhancement

    International Nuclear Information System (INIS)

    Gonen, E.; Marcus, E.; Wengrowicz, U.; Beck, A.; Nir, J.; Sheinfeld, M.; Broide, A.; Tirosh, D.

    2002-01-01

    A cement analyzing system based on radiation spectroscopy had been developed [1], using novel digital approach for real-time, high-throughput and low-cost Multi Channel Analyzer. The performance of the developed system had a severe problem: the resulted spectrum suffered from lack of smoothness, it was very noisy and full of spikes and surges, therefore it was impossible to use this spectrum for analyzing the cement substance. This paper describes the work carried out to improve the system performance

  7. A multi-channel low-power system-on-chip for single-unit recording and narrowband wireless transmission of neural signal.

    Science.gov (United States)

    Bonfanti, A; Ceravolo, M; Zambra, G; Gusmeroli, R; Spinelli, A S; Lacaita, A L; Angotzi, G N; Baranauskas, G; Fadiga, L

    2010-01-01

    This paper reports a multi-channel neural recording system-on-chip (SoC) with digital data compression and wireless telemetry. The circuit consists of a 16 amplifiers, an analog time division multiplexer, an 8-bit SAR AD converter, a digital signal processor (DSP) and a wireless narrowband 400-MHz binary FSK transmitter. Even though only 16 amplifiers are present in our current die version, the whole system is designed to work with 64 channels demonstrating the feasibility of a digital processing and narrowband wireless transmission of 64 neural recording channels. A digital data compression, based on the detection of action potentials and storage of correspondent waveforms, allows the use of a 1.25-Mbit/s binary FSK wireless transmission. This moderate bit-rate and a low frequency deviation, Manchester-coded modulation are crucial for exploiting a narrowband wireless link and an efficient embeddable antenna. The chip is realized in a 0.35- εm CMOS process with a power consumption of 105 εW per channel (269 εW per channel with an extended transmission range of 4 m) and an area of 3.1 × 2.7 mm(2). The transmitted signal is captured by a digital TV tuner and demodulated by a wideband phase-locked loop (PLL), and then sent to a PC via an FPGA module. The system has been tested for electrical specifications and its functionality verified in in-vivo neural recording experiments.

  8. A multi-channel THz and infrared spectrometer for femtosecond electron bunch diagnostics by single-shot spectroscopy of coherent radiation

    International Nuclear Information System (INIS)

    Wesch, Stephan; Schmidt, Bernhard; Behrens, Christopher; Delsim-Hashemi, Hossein; Schmueser, Peter

    2011-08-01

    The high peak current required in free-electron lasers (FELs) is realized by longitudinal compression of the electron bunches to sub-picosecond length. In this paper, a frequency-domain diagnostic method is described that is capable of resolving structures in the femtosecond regime. A novel in-vacuum spectrometer has been developed for spectroscopy of coherent radiation in the THz and infrared range. The spectrometer is equipped with five consecutive dispersion gratings and 120 parallel readout channels; it can be operated either in short wavelength mode (5-44 μm) or in long wavelength mode (45-430 μm). Fast parallel readout permits the spectroscopy of coherent radiation from single electron bunches. Test measurements at the soft X-ray free-electron laser FLASH, using coherent transition radiation, demonstrate excellent performance of the spectrometer. The high sensitivity down to a few micrometers allows study of short bunch features caused for example by microbunching e ects in magnetic chicanes. The device is planned for use as an online bunch profile monitor during regular FEL operation. (orig.)

  9. A multi-channel THz and infrared spectrometer for femtosecond electron bunch diagnostics by single-shot spectroscopy of coherent radiation

    Energy Technology Data Exchange (ETDEWEB)

    Wesch, Stephan; Schmidt, Bernhard; Behrens, Christopher; Delsim-Hashemi, Hossein; Schmueser, Peter

    2011-08-15

    The high peak current required in free-electron lasers (FELs) is realized by longitudinal compression of the electron bunches to sub-picosecond length. In this paper, a frequency-domain diagnostic method is described that is capable of resolving structures in the femtosecond regime. A novel in-vacuum spectrometer has been developed for spectroscopy of coherent radiation in the THz and infrared range. The spectrometer is equipped with five consecutive dispersion gratings and 120 parallel readout channels; it can be operated either in short wavelength mode (5-44 {mu}m) or in long wavelength mode (45-430 {mu}m). Fast parallel readout permits the spectroscopy of coherent radiation from single electron bunches. Test measurements at the soft X-ray free-electron laser FLASH, using coherent transition radiation, demonstrate excellent performance of the spectrometer. The high sensitivity down to a few micrometers allows study of short bunch features caused for example by microbunching e ects in magnetic chicanes. The device is planned for use as an online bunch profile monitor during regular FEL operation. (orig.)

  10. Design and test of a 434 MHz multi-channel amplifier system for targeted hyperthermia applicators

    NARCIS (Netherlands)

    Bakker, J. F.; Paulides, M. M.; Westra, A. H.; Schippers, H.; Van Rhoon, G. C.

    2010-01-01

    Purpose: For our head-and-neck hyperthermia ( HT) applicator, an amplifier system with full amplitude and phase-control to deliver the radio-frequency signals, was not available. We therefore designed and tested a 433.92 MHz multi-channel amplifier system. System description: The design consists of

  11. Modelling customer behaviour in multi-channel service distribution

    NARCIS (Netherlands)

    Heinhuis, D.; de Vries, E.J.; Kundisch, D.; Veit, D.J.; Weitzel, T.; Weinhardt, C.

    2009-01-01

    Financial service providers are innovating their distribution strategy into multi-channel strategies. The success of a multi-channel approach and the high investments made in information systems and enterprise architectures depends on the adoption and multi-channel usage behaviour of consumers. We

  12. Multi-Channel Capacitive Sensor Arrays

    OpenAIRE

    Wang, Bingnan; Long, Jiang; Teo, Koon Hoo

    2016-01-01

    In this paper, multi-channel capacitive sensor arrays based on microstrip band-stop filters are studied. The sensor arrays can be used to detect the proximity of objects at different positions and directions. Each capacitive sensing structure in the array is connected to an inductive element to form resonance at different frequencies. The resonances are designed to be isolated in the frequency spectrum, such that the change in one channel does not affect resonances at other channels. The indu...

  13. Multi-channel motor evoked potential monitoring during anterior cervical discectomy and fusion

    Directory of Open Access Journals (Sweden)

    Dong-Gun Kim

    Full Text Available Objectives: Anterior cervical discectomy and fusion (ACDF surgery is the most common surgical procedure for the cervical spine with low complication rate. Despite the potential prognostic benefit, intraoperative neurophysiological monitoring (IONM, a method for detecting impending neurological compromise, is not routinely used in ACDF surgery. The present study aimed to identify the potential benefits of monitoring multi-channel motor evoked potentials (MEPs during ACDF surgery. Methods: We retrospectively reviewed 200 consecutive patients who received IONM with multi-channel MEPs and somatosensory evoked potentials (SSEPs. On average, 9.2 muscles per patient were evaluated under MEP monitoring. Results: The rate of MEP change during surgery in the multi-level ACDF group was significantly higher than the single-level group. Two patients from the single-level ACDF group (1.7% and four patients from the multi-level ACDF group (4.9% experienced post-operative motor deficits. Multi-channel MEPs monitoring during single and multi-level ACDF surgery demonstrated higher sensitivity, specificity, positive predictive and negative predictive value than SSEP monitoring. Conclusions: Multi-channel MEP monitoring might be beneficial for the detection of segmental injury as well as long tract injury during single- and multi-level ACDF surgery. Significance: This is first large scale study to identify the usefulness of multi-channel MEPs in monitoring ACDF surgery. Keywords: Disc disease, Somatosensory evoked potentials, Intraoperative neurophysiological monitoring, Motor evoked potentials, Anterior cervical discectomy and fusion

  14. FPGA applications for single dish activity at Medicina radio telescopes

    Science.gov (United States)

    Bartolin, M.; Nald, G.; Mattan, A.; Maccaferr, A.; De Biagg, M.

    FPGA technologies are gaining major attention in the recent years in the field of radio astronomy. At Medicina radio telescopes, FPGAs have been used in the last ten years for a number of purposes and in this article we will take into exam the applications developed and installed for the Medicina Single Dish 32m Antenna: these range from high performance digital signal processing to instrument control developed on top of smaller FPGAs.

  15. Multi-channel coherent perfect absorbers

    KAUST Repository

    Bai, Ping

    2016-05-18

    The absorption efficiency of a coherent perfect absorber usually depends on the phase coherence of the incident waves on the surfaces. Here, we present a scheme to create a multi-channel coherent perfect absorber in which the constraint of phase coherence is loosened. The scheme has a multi-layer structure such that incident waves in different channels with different angular momenta can be simultaneously and perfectly absorbed. This absorber is robust in achieving high absorption efficiency even if the incident waves become "incoherent" and possess "random" wave fronts. Our work demonstrates a unique approach to designing highly efficient metamaterial absorbers. © CopyrightEPLA, 2016.

  16. A multi-channel coronal spectrophotometer.

    Science.gov (United States)

    Landman, D. A.; Orrall, F. Q.; Zane, R.

    1973-01-01

    We describe a new multi-channel coronal spectrophotometer system, presently being installed at Mees Solar Observatory, Mount Haleakala, Maui. The apparatus is designed to record and interpret intensities from many sections of the visible and near-visible spectral regions simultaneously, with relatively high spatial and temporal resolution. The detector, a thermoelectrically cooled silicon vidicon camera tube, has its central target area divided into a rectangular array of about 100,000 pixels and is read out in a slow-scan (about 2 sec/frame) mode. Instrument functioning is entirely under PDP 11/45 computer control, and interfacing is via the CAMAC system.

  17. FIREMAN: foraging-inspired radio-communication energy management for green multi-radio networks

    CSIR Research Space (South Africa)

    Olwal, TO

    2013-11-01

    Full Text Available resource allocation (AFRRA) protocol module built from an energy-aware multi-radio unification protocol (MUP) [8]. This module virtualises functions of multiple MACs and PHYs layers so that the application layers can only visualise the homogenous single... size. Transmitting large payloads was more energy efficient under saturated conditions than small payloads. The exploitation of the multi-channel MAC layer to provide an energy and spectrum efficient throughput had stimulated a flurry...

  18. Miniaturized multi channel infrared optical gas sensor system

    Science.gov (United States)

    Wöllenstein, Jürgen; Eberhardt, Andre; Rademacher, Sven; Schmitt, Katrin

    2011-06-01

    Infrared spectroscopy uses the characteristic absorption of the molecules in the mid infrared and allows the determination of the gases and their concentration. Especially by the absorption at longer wavelengths between 8 μm and 12 μm, the so called "fingerprint" region, the molecules can be measured with highest selectivity. We present an infrared optical filter photometer for the analytical determination of trace gases in the air. The challenge in developing the filter photometer was the construction of a multi-channel system using a novel filter wheel concept - which acts as a chopper too- in order to measure simultaneously four gases: carbon monoxide, carbon dioxide, methane and ammonia. The system consists of a broadband infrared emitter, a long path cell with 1.7m optical path length, a filter wheel and analogue and digital signal processing. Multi channel filter photometers normally need one filter and one detector per target gas. There are small detection units with one, two or more detectors with integrated filters available on the market. One filter is normally used as reference at a wavelength without any cross-sensitivities to possible interfering gases (e.g. at 3.95 μm is an "atmospheric window" - a small spectral band without absorbing gases in the atmosphere). The advantage of a filter-wheel set-up is that a single IR-detector can be used, which reduces the signal drift enormously. Pyroelectric and thermopile detectors are often integrated in these kinds of spectrometers. For both detector types a modulation of the light is required and can be done - without an additional chopper - with the filter wheel.

  19. Multi-Channel Capacitive Sensor Arrays.

    Science.gov (United States)

    Wang, Bingnan; Long, Jiang; Teo, Koon Hoo

    2016-01-25

    In this paper, multi-channel capacitive sensor arrays based on microstrip band-stop filters are studied. The sensor arrays can be used to detect the proximity of objects at different positions and directions. Each capacitive sensing structure in the array is connected to an inductive element to form resonance at different frequencies. The resonances are designed to be isolated in the frequency spectrum, such that the change in one channel does not affect resonances at other channels. The inductive element associated with each capacitive sensor can be surface-mounted inductors, integrated microstrip inductors or metamaterial-inspired structures. We show that by using metamaterial split-ring structures coupled to a microstrip line, the quality factor of each resonance can be greatly improved compared to conventional surface-mounted or microstrip meander inductors. With such a microstrip-coupled split-ring design, more sensing elements can be integrated in the same frequency spectrum, and the sensitivity can be greatly improved.

  20. Multi-Channel Capacitive Sensor Arrays

    Directory of Open Access Journals (Sweden)

    Bingnan Wang

    2016-01-01

    Full Text Available In this paper, multi-channel capacitive sensor arrays based on microstrip band-stop filters are studied. The sensor arrays can be used to detect the proximity of objects at different positions and directions. Each capacitive sensing structure in the array is connected to an inductive element to form resonance at different frequencies. The resonances are designed to be isolated in the frequency spectrum, such that the change in one channel does not affect resonances at other channels. The inductive element associated with each capacitive sensor can be surface-mounted inductors, integrated microstrip inductors or metamaterial-inspired structures. We show that by using metamaterial split-ring structures coupled to a microstrip line, the quality factor of each resonance can be greatly improved compared to conventional surface-mounted or microstrip meander inductors. With such a microstrip-coupled split-ring design, more sensing elements can be integrated in the same frequency spectrum, and the sensitivity can be greatly improved.

  1. Multi-Channel Deconvolution for Forward-Looking Phase Array Radar Imaging

    Directory of Open Access Journals (Sweden)

    Jie Xia

    2017-07-01

    Full Text Available The cross-range resolution of forward-looking phase array radar (PAR is limited by the effective antenna beamwidth since the azimuth echo is the convolution of antenna pattern and targets’ backscattering coefficients. Therefore, deconvolution algorithms are proposed to improve the imaging resolution under the limited antenna beamwidth. However, as a typical inverse problem, deconvolution is essentially a highly ill-posed problem which is sensitive to noise and cannot ensure a reliable and robust estimation. In this paper, multi-channel deconvolution is proposed for improving the performance of deconvolution, which intends to considerably alleviate the ill-posed problem of single-channel deconvolution. To depict the performance improvement obtained by multi-channel more effectively, evaluation parameters are generalized to characterize the angular spectrum of antenna pattern or singular value distribution of observation matrix, which are conducted to compare different deconvolution systems. Here we present two multi-channel deconvolution algorithms which improve upon the traditional deconvolution algorithms via combining with multi-channel technique. Extensive simulations and experimental results based on real data are presented to verify the effectiveness of the proposed imaging methods.

  2. A multi-channel cooling system for multiple heat source

    Directory of Open Access Journals (Sweden)

    Xu Shanglong

    2016-01-01

    Full Text Available High-power electronic devices with multiple heating elements often require temperature uniformity and operating within their functional temperature range for optimal performance. A multi-channel cooling experiment apparatus is developed for studying heat removal inside an electronic device with multiple heat sources. It mainly consists of a computer-controlled pump, a multi-channel heat sink for multi-zone cooling and the apparatus for measuring the temperature and pressure drop. The experimental results show the system and the designed multi-channel heat sink structure can control temperature distribution of electronic device with multiple heat sources by altering coolant flow rate.

  3. Multi-Channel Optical Digitizer for Earth Sciences

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal was to produce an ASIC (application specific integrated circuit) incorporating a multi-channel optical digitizer for use in image sensor instruments.The...

  4. Salt Plug Formation Caused by Decreased River Discharge in a Multi-channel Estuary

    OpenAIRE

    Shaha, Dinesh Chandra; Cho, Yang-Ki

    2016-01-01

    Freshwater input to estuaries may be greatly altered by the river barrages required to meet human needs for drinking water and irrigation and prevent salt water intrusion. Prior studies have examined the salt plugs associated with evaporation and salt outwelling from tidal salt flats in single-channel estuaries. In this work, we discovered a new type of salt plug formation in the multi-channel Pasur River Estuary (PRE) caused by decreasing river discharges resulting from an upstream barrage. ...

  5. Dynamic multi-channel TMS with reconfigurable coil.

    Science.gov (United States)

    Jiang, Ruoli; Jansen, Ben H; Sheth, Bhavin R; Chen, Ji

    2013-05-01

    Investigations of the causal involvement of particular brain areas and interconnections in behavior require an external stimulation system with reasonable spatio-temporal resolution. Current transcranial magnetic stimulation (TMS) technology is limited to stimulating a single brain area once in a given trial. Here, we present a feasibility study for a novel TMS system based on multi-channel reconfigurable coils. With this hardware, researchers will be able to stimulate multiple brain sites in any temporal order in a trial. The system employs a wire-mesh coil, constructed using x- and y-directional wires. By varying the current direction and/or strength on each wire, we can configure the proposed mesh-wire coil into a standard loop coil and figure-eight coil of varying size. This provides maximum flexibility to the experimenter in that the location and extent of stimulation on the brain surface can be modified depending on experimental requirement. Moreover, one can dynamically and automatically modify the site(s) of stimulation several times within the span of seconds. By pre-storing various sequences of excitation patterns inside a control unit, one can explore the effect of dynamic TMS on behavior, in associative learning, and as rehabilitative therapy. Here, we present a computer simulation and bench experiments that show the feasibility of the dynamically-reconfigurable coil.

  6. High transformer ratio of multi-channel dielectric wakefield structures

    Energy Technology Data Exchange (ETDEWEB)

    Shchelkunov, Sergey V., E-mail: sergey.shchelkunov@gmail.com [Omega-P R& D, Inc, CT 06511 (United States); Yale University, CT (United States); Marshall, Thomas C. [Omega-P R& D, Inc, CT 06511 (United States); Sotnikov, Gennadij V. [NSC Kharkov Institute of Physics and Technology, Kharkov (Ukraine); Hirshfield, Jay L. [Omega-P R& D, Inc, CT 06511 (United States)

    2016-09-01

    Dielectric wakefield (DWA) accelerator concepts are receiving attention on account of their promising performance, mechanical simplicity, and anticipated low cost. Interest in DWA physics directed toward an advanced high-gradient accelerator has been enhanced by a finding that some dielectrics can withstand very high fields (>1 GV/m) for the short times during the passage of charged bunches along dielectric-lined channels. In a two-channel structure, a drive bunch train propagates in a first channel, and in the second adjacent channel where a high gradient wakefield develops, a witness bunch is accelerated. Compared with single-channel DWA's, a two-beam accelerator delivers a high transformer ratio, and thereby reduces the number of drive beam sections needed to achieve a given final test beam energy. An overview of multi-channel DWA structures will be given, with an emphasis on two-channel structures, presenting their advantages and drawbacks, and potential impact on the field. Studies aimed to examine charging rate and charge distribution in a thin walled dielectric wakefield accelerator from a passing charge bunch and the physics of conductivity and discharge phenomena in dielectric materials useful for such accelerator applications are presented in a separate paper in the EAAC-2015 conference proceedings.

  7. Parallel encryption for multi-channel images based on an optical joint transform correlator

    Science.gov (United States)

    Liu, Jie; Bai, Tingzhu; Shen, Xueju; Dou, Shuaifeng; Lin, Chao; Cai, Jianjun

    2017-08-01

    We propose an optical encryption method allowing the parallel encryption for multi-channel images based on a joint transform correlator (JTC). Distinguished from the conventional multi-image encryption methods, our proposed cryptosystem can encrypt multi-channel images simultaneously into a single ciphertext, which also can be used to recover arbitrary original images with corresponding keys. This method can achieve the compressed storage of ciphertext. In order to avoid the cross talk between multi-channel images, we restrict the respective joint power spectrum (JPS) into a specific area with optimized phase masks and split the multiple JPS by controlling the position of single JPS using the linear phase shifts. All of these operations are realized by optimizing and designing the phase masks which can be flexibly reconfigured on the spatial light modulator (SLM), leading to a feasible optical implementation with no increase of optical hardware and complexity. Computer simulations provide the validation for it. Experimental implementation is performed in a JTC-based cryptosystem to further verify the feasibility of our proposed method.

  8. Ideas for future large single dish radio telescopes

    Science.gov (United States)

    Kärcher, Hans J.; Baars, Jacob W. M.

    2014-07-01

    The existing large single dish radio telescopes of the 100m class (Effelsberg, Green Bank) were built in the 1970s and 1990s. With some active optics they work now down to 3 millimeter wavelength where the atmospheric quality of the site is also a limiting factor. Other smaller single dish telescopes (50m LMT Mexico, 30m IRAM Spain) are located higher and reach sub-millimeter quality, and the much smaller 12m antennas of the ALMA array reach at a very high site the Terahertz region. They use advanced technologies as carbon fiber structures and flexible body control. We review natural limits to telescope design and use the examples of a number of telescopes for an overview of the available state-of-the-art in design, engineering and technologies. Without considering the scientific justification we then offer suggestions to realize ultimate performance of huge single dish telescopes (up to 160m). We provide an outlook on design options, technological frontiers and cost estimates.

  9. Research on digital multi-channel pulse height analysis techniques

    International Nuclear Information System (INIS)

    Xiao Wuyun; Wei Yixiang; Ai Xianyun; Ao Qi

    2005-01-01

    Multi-channel pulse height analysis techniques are developing in the direction of digitalization. Based on digital signal processing techniques, digital multi-channel analyzers are characterized by powerful pulse processing ability, high throughput, improved stability and flexibility. This paper analyzes key techniques of digital nuclear pulse processing. With MATLAB software, main algorithms are simulated, such as trapezoidal shaping, digital baseline estimation, digital pole-zero/zero-pole compensation, poles and zeros identification. The preliminary general scheme of digital MCA is discussed, as well as some other important techniques about its engineering design. All these lay the foundation of developing homemade digital nuclear spectrometers. (authors)

  10. Handling Deafness Problem of Scheduled Multi-Channel Polling MACs

    Science.gov (United States)

    Jiang, Fulong; Liu, Hao; Shi, Longxing

    Combining scheduled channel polling with channel diversity is a promising way for a MAC protocol to achieve high energy efficiency and performance under both light and heavy traffic conditions. However, the deafness problem may cancel out the benefit of channel diversity. In this paper, we first investigate the deafness problem of scheduled multi-channel polling MACs with experiments. Then we propose and evaluate two schemes to handle the deafness problem. Our experiment shows that deafness is a significant reason for performance degradation in scheduled multi-channel polling MACs. A proper scheme should be chosen depending on the traffic pattern and the design objective.

  11. The NOD3 software package: A graphical user interface-supported reduction package for single-dish radio continuum and polarisation observations

    Science.gov (United States)

    Müller, Peter; Krause, Marita; Beck, Rainer; Schmidt, Philip

    2017-10-01

    Context. The venerable NOD2 data reduction software package for single-dish radio continuum observations, which was developed for use at the 100-m Effelsberg radio telescope, has been successfully applied over many decades. Modern computing facilities, however, call for a new design. Aims: We aim to develop an interactive software tool with a graphical user interface for the reduction of single-dish radio continuum maps. We make a special effort to reduce the distortions along the scanning direction (scanning effects) by combining maps scanned in orthogonal directions or dual- or multiple-horn observations that need to be processed in a restoration procedure. The package should also process polarisation data and offer the possibility to include special tasks written by the individual user. Methods: Based on the ideas of the NOD2 package we developed NOD3, which includes all necessary tasks from the raw maps to the final maps in total intensity and linear polarisation. Furthermore, plot routines and several methods for map analysis are available. The NOD3 package is written in Python, which allows the extension of the package via additional tasks. The required data format for the input maps is FITS. Results: The NOD3 package is a sophisticated tool to process and analyse maps from single-dish observations that are affected by scanning effects from clouds, receiver instabilities, or radio-frequency interference. The "basket-weaving" tool combines orthogonally scanned maps into a final map that is almost free of scanning effects. The new restoration tool for dual-beam observations reduces the noise by a factor of about two compared to the NOD2 version. Combining single-dish with interferometer data in the map plane ensures the full recovery of the total flux density. Conclusions: This software package is available under the open source license GPL for free use at other single-dish radio telescopes of the astronomical community. The NOD3 package is designed to be

  12. Stacked, filtered multi-channel X-ray diode array

    Energy Technology Data Exchange (ETDEWEB)

    MacNeil, Lawrence [National Security Technologies, LLC. (NSTec), Mercury, NV (United States); Dutra, Eric [National Security Technologies, LLC. (NSTec), Mercury, NV (United States); Raphaelian, Mark [National Security Technologies, LLC. (NSTec), Mercury, NV (United States); Compton, Steve [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Jacoby, Barry [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-08-01

    There are many types of X-ray diodes used for X-ray flux or spectroscopic measurements and for estimating the spectral shape of the VUV to soft X-ray spectrum. However, a need exists for a low-cost, robust X-ray diode to use for experiments in hostile environments on multiple platforms, and for experiments that utilize forces that may destroy the diode(s). Since the typical proposed use required a small size with a minimal single line-of-sight, a parallel array could not be used. So, a stacked, filtered multi-channel X-ray diode array was developed, called the MiniXRD. To achieve significant cost savings while maintaining robustness and ease of field setup, repair, and replacement, we designed the system to be modular. The filters were manufactured in-house and cover the range from 450 eV to 5000 eV. To achieve the line-of-sight accuracy needed, we developed mounts and laser alignment techniques. We modeled and tested elements of the diode design at NSTec Livermore Operations (NSTec / LO) to determine temporal response and dynamic range, leading to diode shape and circuitry changes to optimize impedance and charge storage. The authors fielded individual and stacked systems at several national facilities as ancillary "ride-along" diagnostics to test and improve the design usability. This paper presents the MiniXRD system performance, which supports consideration as a viable low-costalternative for multiple-channel low-energy X-ray measurements. This diode array is currently at Technical Readiness Level (TRL) 6.

  13. Online purchase intentions: A multi-channel store image perspective

    NARCIS (Netherlands)

    Verhagen, T.; van Dolen, W.

    2009-01-01

    The advantages of the bricks-and-clicks retail format in the battle for the online customer has been widely discussed but empirical research on it has been limited. We applied a multi-channel store image perspective to assess its influence on online purchase intentions. Drawing on a sample of 630

  14. A high-speed interface for multi-channel analyzer

    International Nuclear Information System (INIS)

    Shen Ji; Zheng Zhong; Qiao Chong; Chen Ziyu; Ye Yunxiu; Ye Zhenyu

    2003-01-01

    This paper presents a high-speed computer interface for multi-channel analyzer based on DMA technique. Its essential principle and operating procedure are introduced. By the detecting of γ spectrum of 137 Cs with the interface, it's proved that the interface can meet the requirements of high-speed data acquisition

  15. Multi-channel data high speed acquisition and processing system

    International Nuclear Information System (INIS)

    Ni Qizhi; Tang Jiajun; Zhao Zhihong

    2001-01-01

    A kind of multi-channel data acquisition and process system is described emphasized on the cardinal technical capability, main structure and its working mode, including the design of preamplifier, A/D converter, data buffer memory (FIFO), digital signal processing etc. This system can be widely used in apparatus which needs high-speed data acquisition and high-speed digital signal processing

  16. Monolithic DWDM Multi-channel planar waveguide laser

    DEFF Research Database (Denmark)

    Sckerl, Mads W.; Guldberg-Kjær, Søren Andreas; Laurent-Lund, Christian

    1999-01-01

    silica -on-silicon-based multi-channel waveguide laser with four outputs channel with ~ 50 GHz spacing is presented. Excellent control over channel positions and spacings is obtained by the method presented here. Remarkable temperature tuning properties have been obtained....

  17. A multi-channel high-resolution time recorder system

    International Nuclear Information System (INIS)

    Zhang Lingyun; Yang Xiaojun; Song Kezhu; Wang Yanfang

    2004-01-01

    This paper introduces a multi-channel and high-speed time recorder system, which was originally designed to work in the experiments of quantum cryptography research. The novelty of the system is that all the hardware logic is performed by only one FPGA. The system can achieve several desirable features, such as simplicity, high resolution and high processing speed. (authors)

  18. [Multi-channel cochlear implants in patients with Mondini malformation].

    Science.gov (United States)

    Li, Yong-xin; Han, De-min; Zhao, Xiao-tian; Chen, Xue-qing; Kong, Ying; Zheng, Jun; Liu, Bo; Liu, Sha; Mo, Ling-yan; Zhang, Hua; Wang, Shuo

    2004-02-01

    To describe clinical experiences with multi-channel cochlear implantation in patients with Mondini malformation. Among 300 patients who received multi-channel cochlear implants from 1996 to 2002 in Beijing Tongren Hospital, 15 patients were diagnosed with Mondini malformation. A retrospective analysis was performed dealing with the surgical techniques, mapping and rehabilitations characteristics after surgery. 15 patients with normal cochlear structure are consider as control group. Gusher is found more common than the normal cochlear implantation, most of them are serious. The electrodes are inserted in the "cochleostomy" in full length of 13 Patients, 2 pairs of electrodes remains outside of "cochleostomy" in 2 patients. No serious complications occurred after implantation. All patients have auditory sensations. The impedance of the electrodes, the T level, C level and the hearing threshold are similar with the normal cochlear implantation group. The results have no significant difference in compare with normal cochlear group(P > 0.05). Multi-channel cochlear implantation could be performed safely in patients with Mondini malformation. The primary outcome for patients with Mondini malformation are similar to those with normal cochlear structure following the multi-channel cochlear implantation.

  19. Multi-channel service concept design and prototyping

    NARCIS (Netherlands)

    Sperling, C.P.; Simons, L.P.A.; Bouwman, W.A.G.A.

    2007-01-01

    Designing e-services which have to function in a multi-channel context has proved to be challenging for organizations. Previous research has shown that structured design methods are useful to structure the design process. In this paper we proceed from an existing method (which identifies

  20. The Art of Multi-channel Hypermedia Application Development

    NARCIS (Netherlands)

    Synodinos, Dionysios G.; Avgeriou, Paris

    2003-01-01

    The plethora of networked devices and platforms that continuously come to light, as well as the emergence of alternative ways to access the internet, have increased the demand for multi-channel access to hypermedia applications. Researchers and practitioners nowadays not only have to deal with the

  1. A multi-channel waveform digitizer system

    International Nuclear Information System (INIS)

    Bieser, F.; Muller, W.F.J.

    1990-01-01

    The authors report on the design and performance of a multichannel waveform digitizer system for use with the Multiple Sample Ionization Chamber (MUSIC) Detector at the Bevalac. 128 channels of 20 MHz Flash ADC plus 256 word deep memory are housed in a single crate. Digital thresholds and hit pattern logic facilitate zero suppression during readout which is performed over a standard VME bus

  2. Multi-channel particle observation instrument

    International Nuclear Information System (INIS)

    Matsumoto, Haruya; Kaya, Nobuyuki

    1978-01-01

    In space particle measurement, the data obtained are a function of time of measurement, place, energy and pitch angle. The methods to measure energy and pitch angle distributions simultaneously with a single analyzer were investigated. The one is the method to measure energy distribution at a pitch angle at the same time, using a magnetic field type analyzer. This is similar to ordinary magnetic field type analyzers with plural detecting ports. It is simple in construction, low cost, and the measurable energy range can be changed by employing electromagnets. However, its shortcoming is that the measurement of protons can not be made. The other is the method to measure the pitch angle distribution at a certain energy simultaneously using a quadrant sphere electrostatic analyzer, in which energy distribution is analyzed by potential difference between outer and inner spheres. Since incident particles are deflected only in the direction to the center of the quadrant sphere, analysis of incident angle becomes possible by providing with plural detecting ports on the detecting surface. Though it enables both electron and proton measurements, and the energy scanning is easy, it is rather complicated in construction and tends to be influenced by disturbances due to ultra-violet ray and high energy particles because it has no collimator. To eliminate those background noises, acceleration at the prestage of the analyzer and the secondary electron removal inside the analyzer by retarding at the inlet of a secondary electron multiplier have been considered, and are now under experiments. (Wakatsuki, Y.)

  3. A Novel Spectrally Efficient Asynchronous Multi-Channel MAC Using a Half-Duplex Transceiver for Wireless Networks

    Directory of Open Access Journals (Sweden)

    Abdullah Devendiran

    2018-01-01

    Full Text Available Multi-channel medium access control (MAC protocols maximize network performance by enabling concurrent wireless transmissions over non-interfering channels. Despite physical layer advancements, the underlying IEEE 802.11 MAC standard cannot fully exploit features and support high-performance applications. In this work, we propose the novel spectrally efficient asynchronous multi-channel MAC (SA-MMAC protocol for wireless networks using a single half-duplex transceiver. A full-duplex mode of operation on data channels reduces the signaling overhead and boosts the spectrum efficiency. A revamped contention mechanism of IEEE 802.11 addresses the multi-channel hidden terminal problem, and a jamming signal from the receiver addresses the collisions in control signals. Furthermore, the control channel is used for data transmissions to increase the bandwidth utilization but under a restricted half-duplex mode to avoid causing a bottleneck situation. The simulator is tested for correctness. The results suggest that the protocol can work well on 3, 4, or 12 concurrent channels with high node density, providing about 12.5 times more throughput than IEEE 802.11 and 18% to 95% more throughput than its multi-channel variants under saturated traffic conditions.

  4. A multi-channel objective model for the Full-Reference assessment of color pictures

    OpenAIRE

    De Simone, Francesca; Ansorge, Michael; Ebrahimi, Touradj

    2008-01-01

    This paper presents a new approach for the design of a full reference objective quality metric for the assessment of color pictures. Our goal is to build a multi-channel metric based on the perceptual weighting of single-channel metrics. A psycho-visual experiment is thus designed in order to determine the values of the weighting factors. This metric is expected to provide a new useful tool for the quality assessment of compressed pictures in the framework of codec performance evaluation.

  5. Multi-channel temperature measurement system for automotive battery stack

    Science.gov (United States)

    Lewczuk, Radoslaw; Wojtkowski, Wojciech

    2017-08-01

    A multi-channel temperature measurement system for monitoring of automotive battery stack is presented in the paper. The presented system is a complete battery temperature measuring system for hybrid / electric vehicles that incorporates multi-channel temperature measurements with digital temperature sensors communicating through 1-Wire buses, individual 1-Wire bus for each sensor for parallel computing (parallel measurements instead of sequential), FPGA device which collects data from sensors and translates it for CAN bus frames. CAN bus is incorporated for communication with car Battery Management System and uses additional CAN bus controller which communicates with FPGA device through SPI bus. The described system can parallel measure up to 12 temperatures but can be easily extended in the future in case of additional needs. The structure of the system as well as particular devices are described in the paper. Selected results of experimental investigations which show proper operation of the system are presented as well.

  6. Multi-channel PSD Estimators for Speech Dereverberation

    DEFF Research Database (Denmark)

    Kuklasinski, Adam; Doclo, Simon; Gerkmann, Timo

    2015-01-01

    densities (PSDs). We first derive closed-form expressions for the mean square error (MSE) of both PSD estimators and then show that one estimator – previously used for speech dereverberation by the authors – always yields a better MSE. Only in the case of a two microphone array or for special spatial......In this paper we perform an extensive theoretical and experimental comparison of two recently proposed multi-channel speech dereverberation algorithms. Both of them are based on the multi-channel Wiener filter but they use different estimators of the speech and reverberation power spectral...... distributions of the interference both estimators yield the same MSE. The theoretically derived MSE values are in good agreement with numerical simulation results and with instrumental speech quality measures in a realistic speech dereverberation task for binaural hearing aids....

  7. Multi-channel fiber optic dew and humidity sensor

    Science.gov (United States)

    Limodehi, Hamid E.; Mozafari, Morteza; Amiri, Hesam; Légaré, François

    2018-03-01

    In this article, we introduce a multi-channel fiber optic dew and humidity sensor which works using a novel method based on relation between surface plasmon resonance (SPR) and water vapor condensation. The proposed sensor can instantly detect moisture or dew formation through its fiber optic channels, separately situated in different places. It enables to simultaneously measure the ambient Relative Humidity (RH) and dew point temperature of several environments with accuracy of 5%.

  8. Investigations of Orchestra Auralizations Using the Multi-Channel Multi-Source Auralization Technique

    DEFF Research Database (Denmark)

    Vigeant, Michelle; Wang, Lily M.; Rindel, Jens Holger

    2008-01-01

    a multi-channel multi-source auralization technique, involving individual five-channel anechoic recordings of each instrumental part of two symphonies. In the first study, these auralizations were subjectively compared to orchestra auralizations made using (a) a single omni-directional source, (b......) a surface source, and (c) single-channel multi-source method. Results show that the multi-source auralizations were rated to be more realistic than the surface source ones and to have larger source width than the single omni-directional source auralizations. No significant differences were found between......Room acoustics computer modeling is a tool for generating impulse responses and auralizations from modeled spaces. The auralizations are commonly made from a single-channel anechoic recording of solo instruments. For this investigation, auralizations of an entire orchestra were created using...

  9. Radio-frequency reflectometry on an undoped AlGaAs/GaAs single electron transistor

    DEFF Research Database (Denmark)

    MacLeod, S. J.; See, A. M.; Keane, Z. K.

    2014-01-01

    Radio frequency reflectometry is demonstrated in a sub-micron undoped AlGaAs/GaAs device. Undoped single electron transistors (SETs) are attractive candidates to study single electron phenomena, due to their charge stability and robust electronic properties after thermal cycling. However, these d......Radio frequency reflectometry is demonstrated in a sub-micron undoped AlGaAs/GaAs device. Undoped single electron transistors (SETs) are attractive candidates to study single electron phenomena, due to their charge stability and robust electronic properties after thermal cycling. However...

  10. A Low-cost Multi-channel Analogue Signal Generator

    CERN Document Server

    Müller, F; The ATLAS collaboration; Shen, W; Stamen, R

    2009-01-01

    A scalable multi-channel analogue signal generator is presented. It uses a commercial low-cost graphics card with multiple outputs in a standard PC as signal source. Each color signal serves as independent channel to generate an analogue signal. A custom-built external PCB was developed to adjust the graphics card output voltage levels for a specific task, which needed differential signals. The system furthermore comprises a software package to program the signal shape. The implementation of the signal generator is presented as well as an application where it was successfully utilized.

  11. A Low-cost Multi-channel Analogue Signal Generator

    CERN Document Server

    Müller, F; The ATLAS collaboration; Shen, W; Stamen, R

    2009-01-01

    A scalable multi-channel analogue signal generator is presented. It uses a commercial low-cost graphics card with multiple outputs in a standard PC as signal source. Each color signal serves as independent channel to generate an analogue signal. A custom-built external PCB was developed to adjust the graphics card output voltage levels for a specific task, which needed differential signals. The system furthermore comprises a software package to program the signal shape. The signal generator was successfully used as independent test bed for the ATLAS Level-1 Trigger Pre-Processor, providing up to 16 analogue signals.

  12. Salt intrusion in multi-channel estuaries: a case study in the Mekong Delta, Vietnam

    Directory of Open Access Journals (Sweden)

    A. D. Nguyen

    2006-01-01

    Full Text Available There is a well-tested theory for the computation of salt intrusion in alluvial estuaries that is fully analytical and predictive. The theory uses analytical equations to predict the mixing behaviour of the estuary based on measurable quantities, such as channel topography, river discharge and tidal characteristics. It applies to single-channel topographies and estuaries that demonstrate moderate tidal damping. The Mekong delta is a multi-channel estuary where the tide is damped due to a relatively strong river discharge (in the order of 2000 m3/s, even during the dry season. As a result the Mekong is a strongly riverine estuary. This paper aims to test if the theory can be applied to such a riverine multi-channel estuary, and to see if possible adjustments or generalisations need to be made. The paper presents salt intrusion measurements that were done by moving boat in 2005, to which the salt intrusion model was calibrated. The theory has been expanded to cater for tidal damping. Subsequently the model has been validated with observations made at fixed locations over the years 1998 and 1999. Finally it has been tested whether the Mekong calibration fits the overall predictive equations derived in other estuaries. The test has been successful and led to a slight adjustment of the predictive equation to cater for estuaries that experience a sloping bottom.

  13. Distributed capillary adiabatic tissue homogeneity model in parametric multi-channel blind AIF estimation using DCE-MRI.

    Science.gov (United States)

    Kratochvíla, Jiří; Jiřík, Radovan; Bartoš, Michal; Standara, Michal; Starčuk, Zenon; Taxt, Torfinn

    2016-03-01

    One of the main challenges in quantitative dynamic contrast-enhanced (DCE) MRI is estimation of the arterial input function (AIF). Usually, the signal from a single artery (ignoring contrast dispersion, partial volume effects and flow artifacts) or a population average of such signals (also ignoring variability between patients) is used. Multi-channel blind deconvolution is an alternative approach avoiding most of these problems. The AIF is estimated directly from the measured tracer concentration curves in several tissues. This contribution extends the published methods of multi-channel blind deconvolution by applying a more realistic model of the impulse residue function, the distributed capillary adiabatic tissue homogeneity model (DCATH). In addition, an alternative AIF model is used and several AIF-scaling methods are tested. The proposed method is evaluated on synthetic data with respect to the number of tissue regions and to the signal-to-noise ratio. Evaluation on clinical data (renal cell carcinoma patients before and after the beginning of the treatment) gave consistent results. An initial evaluation on clinical data indicates more reliable and less noise sensitive perfusion parameter estimates. Blind multi-channel deconvolution using the DCATH model might be a method of choice for AIF estimation in a clinical setup. © 2015 Wiley Periodicals, Inc.

  14. Performance Improvement of Wireless Mesh Networks by Using a Combination of Channel-Bonding and Multi-Channel Techniques

    Science.gov (United States)

    Xu, Liang; Yamamoto, Koji; Murata, Hidekazu; Yoshida, Susumu

    In the present paper, the use of a combination of channel-bonding and multi-channel techniques is proposed to improve the performance of wireless mesh networks (WMNs). It is necessary to increase the network throughput by broadening the bandwidth, and two approaches to effectively utilize the broadened bandwidth can be considered. One is the multi-channel technique, in which multiple separate frequency channels are used simultaneously for information transmission. The other is the channel-bonding technique used in IEEE 802.11n, which joins multiple frequency channels into a single broader channel. The former can reduce the channel traffic to mitigate the effect of packet collision, while the latter can increase the transmission rate. In the present paper, these two approaches are compared and their respective advantages are clarified in terms of the network throughput and delay performance assuming the same total bandwidth and a CSMA protocol. Our numerical and simulation results indicate that under low-traffic conditions, the channel-bonding technique can achieve low delay, while under traffic congestion conditions, the network performance can be improved by using multi-channel technique. Based on this result, the use of a combination of these two techniques is proposed for a WMN, and show that it is better to use a proper channel technique according to the network traffic condition. The findings of the present study also contribute to improving the performance of a multimedia network, which consists of different traffic types of applications.

  15. Multi-channel electrical impedance tomography for regional tissue hydration monitoring

    International Nuclear Information System (INIS)

    Chen, Xiaohui; Kao, Tzu-Jen; Ashe, Jeffrey M; Boverman, Gregory; Sabatini, James E; Davenport, David M

    2014-01-01

    Poor assessment of hydration status during hemodialysis can lead to under- or over-hydration in patients with consequences of increased morbidity and mortality. In current practice, fluid management is largely based on clinical assessments to estimate dry weight (normal hydration body weight). However, hemodialysis patients usually have co-morbidities that can make the signs of fluid status ambiguous. Therefore, achieving normal hydration status remains a major challenge for hemodialysis therapy. Electrical impedance technology has emerged as a promising method for hydration monitoring due to its non-invasive nature, low cost and ease-of-use. Conventional electrical impedance-based hydration monitoring systems employ single-channel current excitation (either 2-electrode or 4-electrode methods) to perturb and extract averaged impedance from bulk tissue and use generalized models from large populations to derive hydration estimates. In the present study, a prototype, single-frequency electrical impedance tomography (EIT) system with simultaneous multi-channel current excitation was used to enable regional hydration change detection. We demonstrated the capability to detect a difference in daily impedance change between left leg and right leg in healthy human subjects, who wore a compression sock only on one leg to reduce daily gravitational fluid accumulation. The impedance difference corresponded well with the difference of lower leg volume change between left leg and right leg measured by volumetry, which on average is ∼35 ml, accounting for 0.7% of the lower leg volume. We have demonstrated the feasibility of using multi-channel EIT to extract hydration information in different tissue layers with minimal skin interference. Our simultaneous, multi-channel current excitation approach provides an effective method to separate electrode contact impedance and skin condition artifacts from hydration signals. The prototype system has the potential to be used in

  16. Multi-channel unidirectional transmission of phononic crystal heterojunctions

    Science.gov (United States)

    Xu, Zhenlong; Tong, Jie; Wu, Fugen

    2018-02-01

    Two square steel columns are arranged in air to form two-dimensional square lattice phononic crystals (PNCs). Two PNCs can be combined into a non-orthogonal 45∘ heterojunction when the difference in the directional band gaps of the two PNC types is utilized. The finite element method is used to calculate the acoustic band structure, the heterogeneous junction transmission characteristics, acoustic field distribution, and many others. Results show that a non-orthogonal PNC heterojunction can produce a multi-channel unidirectional transmission of acoustic waves. With the square scatterer rotated, the heterojunction can select a frequency band for unidirectional transmission performance. This capability is particularly useful for constructing acoustic diodes with wide-bands and high-efficiency unidirectional transmission characteristics.

  17. A high-throughput, multi-channel photon-counting detector with picosecond timing

    CERN Document Server

    Lapington, J S; Miller, G M; Ashton, T J R; Jarron, P; Despeisse, M; Powolny, F; Howorth, J; Milnes, J

    2009-01-01

    High-throughput photon counting with high time resolution is a niche application area where vacuum tubes can still outperform solid-state devices. Applications in the life sciences utilizing time-resolved spectroscopies, particularly in the growing field of proteomics, will benefit greatly from performance enhancements in event timing and detector throughput. The HiContent project is a collaboration between the University of Leicester Space Research Centre, the Microelectronics Group at CERN, Photek Ltd., and end-users at the Gray Cancer Institute and the University of Manchester. The goal is to develop a detector system specifically designed for optical proteomics, capable of high content (multi-parametric) analysis at high throughput. The HiContent detector system is being developed to exploit this niche market. It combines multi-channel, high time resolution photon counting in a single miniaturized detector system with integrated electronics. The combination of enabling technologies; small pore microchanne...

  18. Device for modular input high-speed multi-channel digitizing of electrical data

    Science.gov (United States)

    VanDeusen, Alan L.; Crist, Charles E.

    1995-09-26

    A multi-channel high-speed digitizer module converts a plurality of analog signals to digital signals (digitizing) and stores the signals in a memory device. The analog input channels are digitized simultaneously at high speed with a relatively large number of on-board memory data points per channel. The module provides an automated calibration based upon a single voltage reference source. Low signal noise at such a high density and sample rate is accomplished by ensuring the A/D converters are clocked at the same point in the noise cycle each time so that synchronous noise sampling occurs. This sampling process, in conjunction with an automated calibration, yields signal noise levels well below the noise level present on the analog reference voltages.

  19. Determination of optimum "multi-channel surface wave method" field parameters.

    Science.gov (United States)

    2012-12-01

    Multi-channel surface wave methods (especially the multi-channel analyses of surface wave method; MASW) are routinely used to : determine the shear-wave velocity of the subsurface to depths of 100 feet for site classification purposes. Users are awar...

  20. The use of service channels by citizens in the Netherlands: implications for multi-channel management

    NARCIS (Netherlands)

    Pieterson, Willem Jan; Ebbers, Wolfgang E.

    2008-01-01

    Many governmental organizations are changing their service channel management strategies to multi-channel management. However, very few empirical studies exist that explore how these multi-channel strategies should be shaped. In this article we test a number of hypotheses on citizens' channel use

  1. Radio frequency scanning tunneling spectroscopy for single-molecule spin resonance.

    Science.gov (United States)

    Müllegger, Stefan; Tebi, Stefano; Das, Amal K; Schöfberger, Wolfgang; Faschinger, Felix; Koch, Reinhold

    2014-09-26

    We probe nuclear and electron spins in a single molecule even beyond the electromagnetic dipole selection rules, at readily accessible magnetic fields (few mT) and temperatures (5 K) by resonant radio-frequency current from a scanning tunneling microscope. We achieve subnanometer spatial resolution combined with single-spin sensitivity, representing a 10 orders of magnitude improvement compared to existing magnetic resonance techniques. We demonstrate the successful resonant spectroscopy of the complete manifold of nuclear and electronic magnetic transitions of up to ΔI(z)=±3 and ΔJ(z)=±12 of single quantum spins in a single molecule. Our method of resonant radio-frequency scanning tunneling spectroscopy offers, atom-by-atom, unprecedented analytical power and spin control with an impact on diverse fields of nanoscience and nanotechnology.

  2. Satellite rainfall monitoring over Africa for food security, using multi-channel MSG data

    Science.gov (United States)

    Chadwick, R.; Grimes, D.; Saunders, R.; Blackmore, T.; Francis, P.

    2009-04-01

    Near real-time rainfall estimates are crucial in sub-Saharan Africa for a variety of humanitarian and agricultural purposes. However, for economic and infrastructural reasons, regularly reporting rain-gauges are sparse and precipitation radar networks extremely rare. Satellite rainfall estimates, particularly from geostationary satellites such as Meteosat Second Generation (MSG), present one method of filling this information gap, as they produce data at high temporal and spatial resolution. An algorithm has been developed to produce rainfall estimates for Africa from multi-channel MSG data. The algorithm is calibrated using precipitation radar data collected in Niamey, Niger as part of the African Monsoon Multidisciplinary Analyses (AMMA) project in 2006, and is based on an algorithm used operationally over Europe by the UK Met Office. Contingency tables are used to establish a statistical relationship between multi-channel MSG data and probability of rainfall at several different rain-rate magnitudes as sensed by the radar. Rain-rate estimates can then be produced at a variety of spatial and temporal scales, with MSG scan length (15 minutes) and pixel size (3-4km) as the lower limit. Results will be presented of a validation of this algorithm over the Sahel region of Africa. Rainfall estimates from this algorithm, processed for 2004, will be validated against gridded rain-gauge data at a 0.5 degree and 10 day timescale suitable for drought monitoring purposes. A comparison will also be made against rainfall estimates from the TAMSAT algorithm, which uses single channel IR data from MSG, and has been shown to perform well in the Sahel region.

  3. Multi-channel Analysis of Passive Surface Waves (MAPS)

    Science.gov (United States)

    Xia, J.; Cheng, F. Mr; Xu, Z.; Wang, L.; Shen, C.; Liu, R.; Pan, Y.; Mi, B.; Hu, Y.

    2017-12-01

    Urbanization is an inevitable trend in modernization of human society. In the end of 2013 the Chinese Central Government launched a national urbanization plan—"Three 100 Million People", which aggressively and steadily pushes forward urbanization. Based on the plan, by 2020, approximately 100 million people from rural areas will permanently settle in towns, dwelling conditions of about 100 million people in towns and villages will be improved, and about 100 million people in the central and western China will permanently settle in towns. China's urbanization process will run at the highest speed in the urbanization history of China. Environmentally friendly, non-destructive and non-invasive geophysical assessment method has played an important role in the urbanization process in China. Because human noise and electromagnetic field due to industrial life, geophysical methods already used in urban environments (gravity, magnetics, electricity, seismic) face great challenges. But humanity activity provides an effective source of passive seismic methods. Claerbout pointed out that wavefileds that are received at one point with excitation at the other point can be reconstructed by calculating the cross-correlation of noise records at two surface points. Based on this idea (cross-correlation of two noise records) and the virtual source method, we proposed Multi-channel Analysis of Passive Surface Waves (MAPS). MAPS mainly uses traffic noise recorded with a linear receiver array. Because Multi-channel Analysis of Surface Waves can produces a shear (S) wave velocity model with high resolution in shallow part of the model, MPAS combines acquisition and processing of active source and passive source data in a same flow, which does not require to distinguish them. MAPS is also of ability of real-time quality control of noise recording that is important for near-surface applications in urban environment. The numerical and real-world examples demonstrated that MAPS can be

  4. Multi-Channel Transfer Function with Dimensionality Reduction

    Science.gov (United States)

    Kim, Han Suk; Schulze, Jürgen P.; Cone, Angela C.; Sosinsky, Gina E.; Martone, Maryann E.

    2010-01-01

    The design of transfer functions for volume rendering is a difficult task. This is particularly true for multi-channel data sets, where multiple data values exist for each voxel. In this paper, we propose a new method for transfer function design. Our new method provides a framework to combine multiple approaches and pushes the boundary of gradient-based transfer functions to multiple channels, while still keeping the dimensionality of transfer functions to a manageable level, i.e., a maximum of three dimensions, which can be displayed visually in a straightforward way. Our approach utilizes channel intensity, gradient, curvature and texture properties of each voxel. The high-dimensional data of the domain is reduced by applying recently developed nonlinear dimensionality reduction algorithms. In this paper, we used Isomap as well as a traditional algorithm, Principle Component Analysis (PCA). Our results show that these dimensionality reduction algorithms significantly improve the transfer function design process without compromising visualization accuracy. In this publication we report on the impact of the dimensionality reduction algorithms on transfer function design for confocal microscopy data. PMID:20582228

  5. Multi-Channel Transfer Function with Dimensionality Reduction.

    Science.gov (United States)

    Kim, Han Suk; Schulze, Jürgen P; Cone, Angela C; Sosinsky, Gina E; Martone, Maryann E

    2010-01-18

    The design of transfer functions for volume rendering is a difficult task. This is particularly true for multi-channel data sets, where multiple data values exist for each voxel. In this paper, we propose a new method for transfer function design. Our new method provides a framework to combine multiple approaches and pushes the boundary of gradient-based transfer functions to multiple channels, while still keeping the dimensionality of transfer functions to a manageable level, i.e., a maximum of three dimensions, which can be displayed visually in a straightforward way. Our approach utilizes channel intensity, gradient, curvature and texture properties of each voxel. The high-dimensional data of the domain is reduced by applying recently developed nonlinear dimensionality reduction algorithms. In this paper, we used Isomap as well as a traditional algorithm, Principle Component Analysis (PCA). Our results show that these dimensionality reduction algorithms significantly improve the transfer function design process without compromising visualization accuracy. In this publication we report on the impact of the dimensionality reduction algorithms on transfer function design for confocal microscopy data.

  6. Leveraging multi-channel x-ray detector technology to improve quality metrics for industrial and security applications

    Science.gov (United States)

    Jimenez, Edward S.; Thompson, Kyle R.; Stohn, Adriana; Goodner, Ryan N.

    2017-09-01

    Sandia National Laboratories has recently developed the capability to acquire multi-channel radio- graphs for multiple research and development applications in industry and security. This capability allows for the acquisition of x-ray radiographs or sinogram data to be acquired at up to 300 keV with up to 128 channels per pixel. This work will investigate whether multiple quality metrics for computed tomography can actually benefit from binned projection data compared to traditionally acquired grayscale sinogram data. Features and metrics to be evaluated include the ability to dis- tinguish between two different materials with similar absorption properties, artifact reduction, and signal-to-noise for both raw data and reconstructed volumetric data. The impact of this technology to non-destructive evaluation, national security, and industry is wide-ranging and has to potential to improve upon many inspection methods such as dual-energy methods, material identification, object segmentation, and computer vision on radiographs.

  7. Harnessing mode-selective nonlinear optics for on-chip multi-channel all-optical signal processing

    Directory of Open Access Journals (Sweden)

    Ming Ma

    2016-11-01

    Full Text Available All-optical signal processing based on nonlinear optical effects allows for the realization of important functions in telecommunications including wavelength conversion, optical multiplexing/demultiplexing, Fourier transformation, and regeneration, amongst others, on ultrafast time scales to support high data rate transmission. In integrated photonic subsystems, the majority of all-optical signal processing systems demonstrated to date typically process only a single channel at a time or perform a single processing function, which imposes a serious limitation on the functionality of integrated solutions. Here, we demonstrate how nonlinear optical effects can be harnessed in a mode-selective manner to perform simultaneous multi-channel (two and multi-functional optical signal processing (i.e., regenerative wavelength conversion in an integrated silicon photonic device. This approach, which can be scaled to a higher number of channels, opens up a new degree of freedom for performing a broad range of multi-channel nonlinear optical signal processing functions using a single integrated photonic device.

  8. Sequential multi-channel OCT in the retina using high-speed fiber optic switches

    Science.gov (United States)

    Wartak, Andreas; Augustin, Marco; Beer, Florian; Haindl, Richard; Baumann, Bernhard; Pircher, Michael; Hitzenberger, Christoph K.

    2017-07-01

    A sequential multi-channel OCT prototype featuring high-speed fiber optical switches to enable inter A-scan (A-scan rate: 100 kHz) sample arm switching was developed and human retinal image data is presented.

  9. Integrated multi-channel vehicle-vehicle and vehicle-roadside communications for ITS

    Science.gov (United States)

    2008-12-01

    This research describes a medium access control (MAC) protocol to Enable multi-channel operation for dedicated short-range communication (DSRC). In particular, we focus on the challenge of supporting potentially high-bandwidth commercial or infotainm...

  10. EDMC: An enhanced distributed multi-channel anti-collision algorithm for RFID reader system

    Science.gov (United States)

    Zhang, YuJing; Cui, Yinghua

    2017-05-01

    In this paper, we proposes an enhanced distributed multi-channel reader anti-collision algorithm for RFID environments which is based on the distributed multi-channel reader anti-collision algorithm for RFID environments (called DiMCA). We proposes a monitor method to decide whether reader receive the latest control news after it selected the data channel. The simulation result shows that it improves interrogation delay.

  11. Surface EMG and muscle fatigue: multi-channel approaches to the study of myoelectric manifestations of muscle fatigue.

    Science.gov (United States)

    Marco, Gazzoni; Alberto, Botter; Taian, Vieira

    2017-05-01

    In a broad view, fatigue is used to indicate a degree of weariness. On a muscular level, fatigue posits the reduced capacity of muscle fibres to produce force, even in the presence of motor neuron excitation via either spinal mechanisms or electric pulses applied externally. Prior to decreased force, when sustaining physically demanding tasks, alterations in the muscle electrical properties take place. These alterations, termed myoelectric manifestation of fatigue, can be assessed non-invasively with a pair of surface electrodes positioned appropriately on the target muscle; traditional approach. A relatively more recent approach consists of the use of multiple electrodes. This multi-channel approach provides access to a set of physiologically relevant variables on the global muscle level or on the level of single motor units, opening new fronts for the study of muscle fatigue; it allows for: (i) a more precise quantification of the propagation velocity, a physiological variable of marked interest to the study of fatigue; (ii) the assessment of regional, myoelectric manifestations of fatigue; (iii) the analysis of single motor units, with the possibility to obtain information about motor unit control and fibre membrane changes. This review provides a methodological account on the multi-channel approach for the study of myoelectric manifestation of fatigue and on the experimental conditions to which it applies, as well as examples of their current applications.

  12. New integrated multi-channel instrumentation for astrophysics

    International Nuclear Information System (INIS)

    Bouyjou, Florent

    2011-01-01

    The solar system exploration and study of the distant universe are still sources of discovery and mystery to the scientific community and for humanity in general. These observations are currently mainly based on the measurement of ions and particles in-situ forming these environments. The observation instruments incorporate spatial sensors, used to convert particles energy into electrical charges measurable. These are closely related to their electronic analog or Analog-Front-End (AFE) and the combination form chains astrophysical detection called 'sensor heads'. In recent years, the desire to improve the spatial and spectral resolution detectors requires the design of a multichannel integrated electronics. Thus, a spatial-type electronic Application Specific Integrated Circuit (ASIC) should be developed. This allows one hand to best adapt to each detector to optimize performance, and on the other hand to benefit from multiples advantages inherent in the use of CMOS technology: reducing the size and transit time signals, multi-function integration, cost reduction for mass production and interference effects studied and well known. However, the spatial constraints require a drastic qualification of the circuit. Indeed, the surrounding radiation can damage electronic systems on board the space missions. By reducing the size, it seems more appropriate today to use technologies for the space (or BiCMOS SOI specific) but rather to implement hardening design techniques (RHBD) on standard technologies that are less expensive and more efficient. The objective of this thesis is the design of new integrated multi-channel instrumentation for space. This work, co-funded by CNES and CNRS, has registered as part of a project supported by the Advanced Research Thematic Network Science and Technology for Aeronautics and Space (RTRA STAE) between 2008 and 2011, called CASA (Channels Astrophysics and their associated instrumentation). In this thesis we have designed two

  13. JADSPE, Multi-Channel Gamma Spectra Unfolding Program

    International Nuclear Information System (INIS)

    Rikovska, J.; Stejskalova, E.

    2005-01-01

    1 - Description of program or function: JADSPE is a package of eight programs to process multi-channel gamma-ray spectra. The programs can be used to: - locate automatically spectral peaks and calculate their positions, areas, and full widths at half maximum (FWHM); - plot the spectra on a CALCOMP plotter, TEKTRONIX terminal or a line printer; - add or subtract several spectra with the possibility of adjusting either their start and end channels or the maxima of the chosen corresponding peaks. The JADSPE package comprises the following programs: - SPECTF: automatic location of peaks and calculation of their positions, areas and FWHMS. The standard deviations of peak parameters are also determined, and each evaluated region is plotted on the line printer. - SPECT1: The areas and FWHMs are calculated for peaks whose positions are known beforehand. The standard deviations of calculated parameters are also determined, and each evaluated region is plotted on the line printer. - PLOCHA: The peak net area is calculated by summing the channel contents in specified regions and by subtracting a linear background. - GRAPH: Spectrum plotting on the line printer. - PLTNEW: Spectrum plotting on CALCOMP plotter or on TEKTRONIX terminal. - SUMDIF: The channel contents of several gamma-ray spectra are added or subtracted. - SSPFP: The channel contents of several gamma-ray spectra are added with adjustment of the maxima of specified peaks. - SOUCET: The channel contents of several gamma-ray spectra are added with the adjustment of start and end channels of the spectra. 2 - Method of solution: Non-linear least-square fit. 3 - Restrictions on the complexity of the problem: The full energy peaks are approximated by a symmetrical Gaussian function and the underlying background is approximated by a first-order polynomial. A fixed spectrum length of 4096 channels is assumed. Maxima of: - number of peaks in one multiplet: 9; - number of peaks identified by the automatic search procedure

  14. Design and test of a 434 MHz multi-channel amplifier system for targeted hyperthermia applicators.

    Science.gov (United States)

    Bakker, J F; Paulides, M M; Westra, A H; Schippers, H; Van Rhoon, G C

    2010-01-01

    For our head-and-neck hyperthermia (HT) applicator, an amplifier system with full amplitude and phase-control to deliver the radio-frequency signals, was not available. We therefore designed and tested a 433.92 MHz multi-channel amplifier system. The design consists of a direct digital synthesizer (DDS) system that generates 12 phase-controlled coherent 433.92 MHz signals, which are amplified to maximum 200 W output per channel. Directional couplers are placed at the amplifiers to couple a small portion of both forward and reflected signals to gain-and-phase detectors. The power setting is applied with a resolution of 2 W and for the phase it is 0.1 degrees . The channels are sequentially sampled at 100 Hz per channel. We tested the performance of the designed amplifier system by measuring the RF spectrum, power and phase accuracy, and by characterising the feedback control by using highly accurate power and phase meters. The spurious emission is less than 60 dBc and the first two harmonic frequencies are suppressed more than 45 dB. The measurement accuracy for the power (+/-5%) is valid for at least 20 days after calibration and for the phase (+/-5 degrees ) it is valid for at least 2 months. The amplifier system operates according to our design criteria to support targeted HT. It can be used for both our in-house developed superficial and head-and-neck HT applicators or any other HT applicator that works on the same frequency of 433.92 MHz.

  15. A new Implementation of the multi-channel analysis in the dosimetry through radiochromic films; Una nueva implementacion del analisis multicanal en la dosimetria mediante peliculas radiocromicas

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Rodriguez, C.; Martin Martin, G.; Bermudez Luna, R.; Lopez Fernandez, A.; Torres Olombrada, M. V. de; Garcia Canibano, T.; Caballero Guerra, P.

    2013-07-01

    The objectives of this study are to implement multi-channel analysis algorithm using open source tools, extend the application of the same to a scanner other than the supported by Micke, generate maps of dose absorbed in compatible format with the PTW Verisoft quality control program and to quantify the improvement in the results of the gamma index as to what would be obtained by applying a conventional single-channel analysis. (Author)

  16. ERPWAVELAB a toolbox for multi-channel analysis of time-frequency transformed event related potentials.

    Science.gov (United States)

    Mørup, Morten; Hansen, Lars Kai; Arnfred, Sidse M

    2007-04-15

    The open source toolbox 'ERPWAVELAB' is developed for multi-channel time-frequency analysis of event related activity of EEG and MEG data. The toolbox provides tools for data analysis and visualization of the most commonly used measures of time-frequency transformed event related data as well as data decomposition through non-negative matrix and multi-way (tensor) factorization. The decompositions provided can accommodate additional dimensions like subjects, conditions or repeats and as such they are perfected for group analysis. Furthermore, the toolbox enables tracking of phase locked activity from one channel-time-frequency instance to another as well as tools for artifact rejection in the time-frequency domain. Several other features are highlighted. ERPWAVELAB can freely be downloaded from www.erpwavelab.org, requires EEGLAB [Delorme A, Makeig S. EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis. J Neurosci Meth 2004;134:9-21] and runs under MATLAB (The Mathworks, Inc.).

  17. A flexible multi-channel high-resolution time-to-digital converter ASIC

    CERN Document Server

    Mota, M; Debieux, S; Ryzhov, V; Moreira, P; Marchioro, A

    2000-01-01

    A data driven multi-channel Time-to-Digital Converter (TDC) circuit with programmable resolution ( similar to 25ps - 8OOps binning) and a dynamic range of 102.4mus has been implemented in a 0.25mum CMOS technology. An on-chip PLL is used for clock multiplication up to 320MHz from an external 40MHz reference. A 32 element Delay Locked Loop (DLL) performs time interpolation down to 97.5ps. Finally, finer time interpolation is obtained using four samples of the DLL separated by 24.5ps generated by an adjustable on-chip RC delay line. In the lower resolution modes of operation, 32 TDC channels are available. In the highest resolution mode eight channels are available, since four low-resolution channels are used to perform a single fine time interpolation. The TDC is capable of measuring both leading and trailing edges of the input signal. Measurements are initially stored as time stamps in individual four-location deep asynchronous channel buffers. After proper encoding, measurements are written into four 256-dee...

  18. The Over-Barrier Resonant States and Multi-Channel Scattering in Multiple Quantum Wells

    Directory of Open Access Journals (Sweden)

    A Polupanov

    2016-09-01

    Full Text Available We demonstrate an explicit numerical method for accurate calculation of the scattering matrix and its poles, and apply this method to describe the multi-channel scattering in the multiple quantum-wells structures. The S-matrix is continued analytically to the unphysical region of complex energy values. Results of calculations show that there exist one or more S-matrix poles, corresponding to the over-barrier resonant states critical for the effect of the absolute reflection of holes in the energy range where only the heavy ones may propagate over barriers in a structure. Light- and heavy-hole states are described by the Luttinger Hamiltonian matrix. In contrast to the single quantum-well case, at some parameters of a multiple quantum-wells structure the number of S-matrix poles may exceed that of the absolute reflection peaks, and at different values of parameters the absolute reflection peak corresponds to different resonant states. The imaginary parts of the S-matrix poles and hence the lifetimes of resonant states as well as the widths of resonant peaks of absolute reflection depend drastically on the quantum-well potential depth. In the case of shallow quantum wells there is in fact a long-living over-barrier resonant hole state.

  19. Optimization of multi-channel neutron focusing guides for extreme sample environments

    International Nuclear Information System (INIS)

    Di Julio, D D; Lelièvre-Berna, E; Andersen, K H; Bentley, P M; Courtois, P

    2014-01-01

    In this work, we present and discuss simulation results for the design of multichannel neutron focusing guides for extreme sample environments. A single focusing guide consists of any number of supermirror-coated curved outer channels surrounding a central channel. Furthermore, a guide is separated into two sections in order to allow for extension into a sample environment. The performance of a guide is evaluated through a Monte-Carlo ray tracing simulation which is further coupled to an optimization algorithm in order to find the best possible guide for a given situation. A number of population-based algorithms have been investigated for this purpose. These include particle-swarm optimization, artificial bee colony, and differential evolution. The performance of each algorithm and preliminary results of the design of a multi-channel neutron focusing guide using these methods are described. We found that a three-channel focusing guide offered the best performance, with a gain factor of 2.4 compared to no focusing guide, for the design scenario investigated in this work.

  20. A multi-channel magnetic induction tomography measurement system for human brain model imaging

    International Nuclear Information System (INIS)

    Xu, Zheng; Luo, Haijun; He, Wei; He, Chuanhong; Song, Xiaodong; Zahng, Zhanglong

    2009-01-01

    This paper proposes a multi-channel magnetic induction tomography measurement system for biological conductivity imaging in a human brain model. A hemispherical glass bowl filled with a salt solution is used as the human brain model; meanwhile, agar blocks of different conductivity are placed in the solution to simulate the intracerebral hemorrhage. The excitation and detection coils are fixed co-axially, and the axial gradiometer is used as the detection coil in order to cancel the primary field. On the outer surface of the glass bowl, 15 sensor units are arrayed in two circles as measurement parts, and a single sensor unit for canceling the phase drift is placed beside the glass bowl. The phase sensitivity of our system is 0.204°/S m −1 with the excitation frequency of 120 kHz and the phase noise is in the range of −0.03° to +0.05°. Only the coaxial detection coil is available for each excitation coil; therefore, 15 phase data are collected in each measurement turn. Finally, the two-dimensional images of conductivity distribution are obtained using an interpolation algorithm. The frequency-varying experiment indicates that the imaging quality becomes better as the excitation frequency is increased

  1. Spectrally shaped DP-16QAM super-channel transmission with multi-channel digital back-propagation.

    Science.gov (United States)

    Maher, Robert; Xu, Tianhua; Galdino, Lidia; Sato, Masaki; Alvarado, Alex; Shi, Kai; Savory, Seb J; Thomsen, Benn C; Killey, Robert I; Bayvel, Polina

    2015-02-03

    The achievable transmission capacity of conventional optical fibre communication systems is limited by nonlinear distortions due to the Kerr effect and the difficulty in modulating the optical field to effectively use the available fibre bandwidth. In order to achieve a high information spectral density (ISD), while simultaneously maintaining transmission reach, multi-channel fibre nonlinearity compensation and spectrally efficient data encoding must be utilised. In this work, we use a single coherent super-receiver to simultaneously receive a DP-16QAM super-channel, consisting of seven spectrally shaped 10GBd sub-carriers spaced at the Nyquist frequency. Effective nonlinearity mitigation is achieved using multi-channel digital back-propagation (MC-DBP) and this technique is combined with an optimised forward error correction implementation to demonstrate a record gain in transmission reach of 85%; increasing the maximum transmission distance from 3190 km to 5890 km, with an ISD of 6.60 b/s/Hz. In addition, this report outlines for the first time, the sensitivity of MC-DBP gain to linear transmission line impairments and defines a trade-off between performance and complexity.

  2. Impedance of the single-electron transistor at radio-frequencies

    International Nuclear Information System (INIS)

    Ciccarelli, C; Ferguson, A J

    2011-01-01

    We experimentally characterize the impedance of a single-electron transistor (SET) at an excitation frequency comparable to the electron tunnel rate. In contrast to usual radio-frequency-SET operations, the excitation signal is applied to the gate of the device. At zero source-drain bias, the SET displays both resistive (Sisyphus resistance) and reactive (tunnelling capacitance) components to its impedance. We study the bias dependence of the complex impedance, investigating its response as the electron tunnel rate becomes large with respect to the driving frequency. The experimental data are compared with values calculated from a master equation model.

  3. Impedance of the single-electron transistor at radio-frequencies

    Science.gov (United States)

    Ciccarelli, C.; Ferguson, A. J.

    2011-09-01

    We experimentally characterize the impedance of a single-electron transistor (SET) at an excitation frequency comparable to the electron tunnel rate. In contrast to usual radio-frequency-SET operations, the excitation signal is applied to the gate of the device. At zero source-drain bias, the SET displays both resistive (Sisyphus resistance) and reactive (tunnelling capacitance) components to its impedance. We study the bias dependence of the complex impedance, investigating its response as the electron tunnel rate becomes large with respect to the driving frequency. The experimental data are compared with values calculated from a master equation model.

  4. Impedance of the single-electron transistor at radio-frequencies

    Energy Technology Data Exchange (ETDEWEB)

    Ciccarelli, C; Ferguson, A J, E-mail: cc538@cam.ac.uk, E-mail: ajf1006@cam.ac.uk [Cavendish Laboratory, University of Cambridge, J J Thomson Avenue, Cambridge CB3 0HE (United Kingdom)

    2011-09-15

    We experimentally characterize the impedance of a single-electron transistor (SET) at an excitation frequency comparable to the electron tunnel rate. In contrast to usual radio-frequency-SET operations, the excitation signal is applied to the gate of the device. At zero source-drain bias, the SET displays both resistive (Sisyphus resistance) and reactive (tunnelling capacitance) components to its impedance. We study the bias dependence of the complex impedance, investigating its response as the electron tunnel rate becomes large with respect to the driving frequency. The experimental data are compared with values calculated from a master equation model.

  5. Spectrum sensing using single-radio switched-beam antenna systems

    DEFF Research Database (Denmark)

    Tsakalaki, Elpiniki; Wilcox, David; De Carvalho, Elisabeth

    2012-01-01

    The paper describes spectrum sensing using single-radio switched-beam arrays with reactance-loaded parasitic elements. At a given frequency, the antenna's loading conditions (reactive loads) are optimized for maximum average beamforming gain in the beampattern look direction. Circular permutations...... of the reactive loads rotate the narrowband beampattern to different angular positions dividing the whole space around the cognitive receiver into several angular subspaces. The beampattern directionality leverages the performance of spectrum sensing algorithms like the energy detection by enhancing the receive...

  6. A Novel Single Pass Authenticated Encryption Stream Cipher for Software Defined Radios

    DEFF Research Database (Denmark)

    Khajuria, Samant

    2012-01-01

    high throughput and low overhead for SDRs. The thesis is divided into two research topics. One topic is the design of a 1-pass authenticated encryption scheme that can accomplish both message secrecy and authenticity in a single cryptographic primitive. The other topic is the implementation......With the rapid growth of new wireless communication standards, a solution that is able to provide a seamless shift between existing wireless protocols and high flexibility as well as capacity is crucial. Software Defined Radio (SDR) technology offers this flexibility. It gives the possibility...

  7. Range based power control for multi-radio multi-channel wireless mesh networks

    CSIR Research Space (South Africa)

    Olwal, TO

    2009-08-01

    Full Text Available ) Here, 2. is the Euclidean norm and υ is the path loss exponent (PLE) assumed to be 2 6υ≤ ≤ , depending on the physical environment conditions [11]. Substitute (3) into (4) to get: Network and Above PMMUP: V-MAC Link Layer MAC # 2 Physical #2... neighbouring nodes. The probability of selecting transmission power that is greater than the probing power level increases with the connectivity range at different path loss exponents (PLE). When the PLE is high it implies bad wireless channel environment...

  8. Modeling of water flow in multi-channel river system in the Narew National Park

    Directory of Open Access Journals (Sweden)

    Marcinkowski Paweł

    2017-09-01

    Full Text Available Modeling of water flow in multi-channel river system in the Narew National Park. Anastomosing rivers constitute a rare example of multi-channel systems, which used to be very common before the agricultural and industrial development. Presently few of them remain worldwide and the only example in Poland is the Upper River Narew within Narew National Park. Although hydraulic modeling using one-dimensional models is commonly used to describe water flow in rivers, for multi-channel rivers problem is more complicated. For this type of rivers it is expected that the feedback between process of plants growth (expressed by Manning’s coefficient and distribution of flow in anabranches is high. However, assignment procedure on roughness coefficients in splitting and rejoining channels is laborious and difficult. Therefore, for efficient water flow modeling in multi-channel systems a stand-alone hydraulic model equipped with automatic optimization procedure was developed. Optimization and validation stages, based on field measurements data of discharge and water levels, indicated that the model accurately simulates water flow in multi-channel system.

  9. The Time Division Multi-Channel Communication Model and the Correlative Protocol Based on Quantum Time Division Multi-Channel Communication

    International Nuclear Information System (INIS)

    Liu Xiao-Hui; Pei Chang-Xing; Nie Min

    2010-01-01

    Based on the classical time division multi-channel communication theory, we present a scheme of quantum time-division multi-channel communication (QTDMC). Moreover, the model of quantum time division switch (QTDS) and correlative protocol of QTDMC are proposed. The quantum bit error rate (QBER) is analyzed and the QBER simulation test is performed. The scheme shows that the QTDS can carry out multi-user communication through quantum channel, the QBER can also reach the reliability requirement of communication, and the protocol of QTDMC has high practicability and transplantable. The scheme of QTDS may play an important role in the establishment of quantum communication in a large scale in the future. (general)

  10. Multianalyte chemical identification and quantitation using a single radio frequency identification sensor.

    Science.gov (United States)

    Potyrailo, Radislav A; Morris, William G

    2007-01-01

    We demonstrate an approach for multianalyte chemical identification and quantitation using a single conventional radio frequency identification (RFID) tag that has been adapted for chemical sensing. Unlike other approaches of using RFID sensors, where a special tag should be designed at a much higher cost, we utilize a conventional RFID tag and coat it with a chemically sensitive film. As an example, we demonstrate detection of several vapors of industrial, health, law enforcement, and security interest (ethanol, methanol, acetonitrile, water vapors) with a single 13.56-MHz RFID tag coated with a solid polymer electrolyte sensing film. By measuring simultaneously several parameters of the complex impedance from such an RFID sensor and applying multivariate statistical analysis methods, we were able to identify and quantify several vapors of interest. With a careful selection of the sensing film and measurement conditions, we achieved parts-per-billion vapor detection limits in air. These RFID sensors are very attractive as ubiquitous multianalyte distributed sensor networks.

  11. A multi-channel humidity control system based on LabVIEW

    International Nuclear Information System (INIS)

    Zhang Aiwu; Xie Yuguang; Liu Hongbang; Liu Yingbiao; Cai Xiao; Yu Boxiang; Lu Junguang; Zhou Li

    2011-01-01

    A real time multi-channel humidity control system was designed based on LabVIEW, using the dry air branch of BESⅢ drying system. The hardware of this control system consist of mini humidity and temperature sensors, intelligent collection module, switch quantity controller and electromagnetic valves. The humidity can be controlled at arbitrary value from air humidity to 3% with accuracy better than 2%. Multi microenvironment with different humidity can be easily controlled and monitored in real time by this system. It can also be extended to hybrid control of multi channel humidity and temperature. (authors)

  12. A Flexible Speech Distortion Weighted Multi-Channel Wiener Filter for Noise Reduction in Hearing Aids

    DEFF Research Database (Denmark)

    Ngo, K.; Moonen, M.; Jensen, Søren Holdt

    2011-01-01

    In this paper, a multi-channel noise reduction algorithm is presented based on a Speech Distortion Weighted Multi-channel Wiener Filter (SDW-MWF) approach that incorporates a flexible weighting factor. A typical SDW-MWF uses a fixed weighting factor to trade-off between noise reduction and speech......-only and a speech+noise state, a solution is introduced that allows for a more flexible trade-off between noise reduction and speech distortion. Experimental results with hearing aid scenarios demonstrate that the proposed SDW-MWF incorporating the flexible weighting factor improves the signal...

  13. The design and implementation of a PC based multi-channel scaler system

    International Nuclear Information System (INIS)

    Wang Qiang; Chinese Academy of Sciences, Beijing; Jin Dapeng; Liu Zhen'an; Zhao Dixin

    2007-01-01

    A multi-channel scaler system is designed for the system check and status monitoring of the BESIII trigger system. It is composed of a PC, two PCI interface multi-channel scaler cards, the corresponding drivers and user programs. Total 64 signals can be scaled and monitored in real time. The scaled data are recorded locally and some of them are distributed to the online system. In this paper, the hardware structure, software development and long time running stability of the system are introduced. (authors)

  14. Radio frequency phototube and optical clock: High resolution, high rate and highly stable single photon timing technique

    Energy Technology Data Exchange (ETDEWEB)

    Margaryan, Amur

    2011-10-01

    A new timing technique for single photons based on the radio frequency phototube and optical clock or femtosecond optical frequency comb generator is proposed. The technique has a 20 ps resolution for single photons, is capable of operating with MHz frequencies and achieving 10 fs instability level.

  15. All-optical UWB generation and modulation using SOA-XPM effect and DWDM-based multi-channel frequency discrimination.

    Science.gov (United States)

    Wang, Fei; Dong, Jianji; Xu, Enming; Zhang, Xinliang

    2010-11-22

    An all-optical UWB pulses generation and modulation scheme using cross phase modulation (XPM) effect of semiconductor optical amplifier (SOA) and DWDM-based multi-channel frequency discrimination is proposed and demonstrated, which has potential application in multiuser UWB-Over-Fiber communication systems. When a Gaussian pulse light and a wavelength-tunable CW probe light are together injected into the SOA, the probe light out from the SOA will have a temporal chirp due to SOA-XPM effect. When the chirped probe light is tuned to the slopes of single DWDM channel transmittance curve, the optical phase modulation to intensity modulation conversion is achieved at DWDM that serves as a multi-channel frequency discriminator, the inverted polarity Gaussian monocycle and doublet pulse is detected by a photodetector, respectively. If the probe lights are simultaneously aimed to different slopes of several DWDM channels, multi-channel or binary-phase-coded UWB signal generation can be acquired. Using proposed scheme, pulse amplitude modulation (PAM), pulse polarity modulation (PPM) and pulse shape modulation (PSM) to UWB pulses also can be conveniently realized.

  16. An S-FSCW Based Multi-Channel Reader System for Beamforming Applications using Surface Acoustic Wave Sensors

    Directory of Open Access Journals (Sweden)

    C. Pfeffer

    2011-12-01

    Full Text Available Interrogating multiple surface acoustic wave (SAW sensors located within the same radar beam require techniques to separate the multiple superposing SAW sensor responses. The presented multi-channel reader features four parallel transceiver channels, which are based on the switched frequency-stepped continuous-wave principle and high-speed parallelized baseband electronics. Thus classical beamforming applications including angle of arrival measurement of single SAW tags and the angular separation of multiple SAW sensors are presented and compared to a multiple-input multiple-output (MIMO approach. Due to the larger virtual array in the MIMO approach a larger aperture can be synthesized, which leads to significantly better angular separation results. The level analysis for the given system is verified by baseband-power measurements at different readout distances, considering the hardware parameters as well as the free-space propagation aspects. Finally measurements assess the maximum interrogation distance for the system.

  17. Single-Dish Radio Polarimetry in the F-GAMMA Program with the Effelsberg 100-m Radio Telescope

    Directory of Open Access Journals (Sweden)

    Beuchert Tobias

    2013-12-01

    Full Text Available Studying the variability of polarized AGN jet emission in the radio band is crucial for understanding the dynamics of moving shocks as well as the structure of the underlying magnetic field. The 100-m Effelsberg Telescope is a high-quality instrument for studying the long-term variability of both total and polarized intensity as well as the electric-vector position angle. Since 2007, the F-GAMMA program has been monitoring the linear polarized emission of roughly 60 blazars at 11 frequencies between 2.7 and 43 GHz. Here, we describe the calibration of the polarimetric data at 5 and 10 GHz and the resulting F-GAMMA full-Stokes light curves for the exemplary case of the radio galaxy 3C 111.

  18. Stereotactic radio surgery and radio frequency rhizotomy for trigeminal neuralgia in multiple sclerosis: A single institution experience.

    Science.gov (United States)

    Holland, Marshall T; Teferi, Nahom; Noeller, Jennifer; Swenson, Andrea; Smith, Mark; Buatti, John; Hitchon, Patrick W

    2017-11-01

    For patients with medically unresponsive trigeminal neuralgia (TN), surgical options include micro vascular decompression (MVD), radiofrequency rhizotomy (RF), and stereotactic radio surgery (SRS). Multiple sclerosis (MS) is a demyelinating condition that can be associated with TN, but is not amenable to treatment with MVD. We sought to identify the outcome differences of patients with TN in MS undergoing SRS or RFR in an attempt to identify factors that may influence outcomes. We also evaluated cost outcomes, both initially and over time, based on the index procedure. We performed a retrospective review of our experience with 17 cases. A single institution retrospective chart review was performed. Since 1997, 17 patients with TN and MS have been treated at our institution. All patients underwent a preoperative MRI to rule out a compressive lesion. Patients either underwent SRS (n=7) or RFR (n=10) as their index procedure and were evaluated as a group based on this first procedure. Outcome measures included preoperative Expand Disability Status Score (EDSS) scores, pre- and postoperative facial pain and medication use, post-intervention facial numbness, need for subsequent procedures, and duration of follow-up. Charges for the index procedure, subsequent interventions, and total costs were tabulated and analyzed in 2017 US dollars, adjusting for inflation. The median age of patients at first operation in each group was 58.5±10.9 and 63.5±7.5 for SRS and RFR respectively. There were no significant differences in basic demographics. Overall, 71% of these patients had an excellent or good initial pain outcome. Over time, 60% of RFR and 29% of SRS patients required additional procedures to obtain satisfactory pain relief. The patients who underwent RFR as their index procedure required a significantly higher number of procedures to achieve adequate pain relief (RFR=2.7 vs SRS=2.0 [p=0.04]). The average index procedure costs in US dollars were significantly different

  19. 120 Gb/s Multi-Channel THz Wireless Transmission and THz Receiver Performance Analysis

    DEFF Research Database (Denmark)

    Jia, Shi; Yu, Xianbin; Hu, Hao

    2017-01-01

    A photonic multi-channel terahertz (THz) wireless transmission system in the 350-475 GHz band is experimentally demonstrated. The employment of six THz carriers modulated with 10 Gbaud Nyquist quadrature phase-shift keying baseband signal per carrier results in an overall capacity of up to 120 Gb...

  20. Implementation issues of a High-Speed distributed Multi-Channel ADDA System

    NARCIS (Netherlands)

    Wesselink, J.M.; Berkhoff, Arthur P.; Laanstra, Geert J.; Kuipers, Hendrik

    2005-01-01

    A multi-channel ADDA controller is used in many active noise cancellation and active vibration control problems. Such a con- troller is able to yield good performance, however it also requires a lot of hardware on a centralized place and a lot of sensitive wiring. A practical work around for this

  1. Exploiting the opportunities of Internet and multi-channel pricing : An exploratory research

    NARCIS (Netherlands)

    Sotgiu, Francesca; Ancarani, Fabio

    2004-01-01

    Smart firms are not worried about the impact of the Internet on pricing, but realise that they have the unique opportunity to exploit new options and improve their marketing performance. Multi-channel pricing is one of the most interesting opportunities firms can exploit in the digital economy.

  2. Maximum likelihood based multi-channel isotropic reverberation reduction for hearing aids

    DEFF Research Database (Denmark)

    Kuklasiński, Adam; Doclo, Simon; Jensen, Søren Holdt

    2014-01-01

    We propose a multi-channel Wiener filter for speech dereverberation in hearing aids. The proposed algorithm uses joint maximum likelihood estimation of the speech and late reverberation spectral variances, under the assumption that the late reverberant sound field is cylindrically isotropic...

  3. The applications of CPLD in a computerized multi-channel nuclear spectrum acquisition system

    International Nuclear Information System (INIS)

    Lu Kun; Zhou Daoyu; Fang Tongxiu

    2002-01-01

    The author presents the applications of CPLD in a computerized multi-channel nuclear spectrum acquisition system which was designed by means of EDA technique and CPLD device. The working principle and design methods of this digital circuitry and system integration with CPLD are also introduced. The features and technical points in system designation are discussed as well

  4. Digital multi-channel pulse height analyzer based on soft core

    International Nuclear Information System (INIS)

    Liang Weiping; Li Jinglun; Hu Yingrui

    2012-01-01

    A kind of digital multi-channel pulse height analyzer (DMCA) was introduced. This system uses the NIOS Ⅱ soft-core processor embedded in a FPGA and the system processes nuclear pulse signal by digital signal processing methods, such as digital trapezoidal filter. The test shows that the system transformation gain is 4096 channel and maximum pulse passing is 200 kcps. (authors)

  5. New-fashioned Multi-channel Analyzer Based on Bipartition Method

    International Nuclear Information System (INIS)

    Liu Mingjian; Zhang Yan; Yan Xuekun; Chen Ying

    2009-01-01

    A new-fashioned digital-analog converter (DAC) which can find the pulse-signal amplitude through dichotomy is devised. With this new DAC method, a 256-channel multi-channel pulse amplitude analyzer (MCA) is designed successfully, and its hardware and software are introduced in detail. This provides a new method for designing MCA. (authors)

  6. E-Fulfillment and Multi-Channel Distribution – A Review

    NARCIS (Netherlands)

    N.A.H. Agatz (Niels); M. Fleischmann (Moritz); J.A.E.E. van Nunen (Jo)

    2006-01-01

    textabstractThis review addresses the specific supply chain management issues of Internet fulfillment in a multi-channel environment. It provides a systematic overview of managerial planning tasks and reviews corresponding quantitative models. In this way, we aim to enhance the understanding of

  7. A multi-channel data acquisition system with high resolution based on microcomputer

    International Nuclear Information System (INIS)

    An Qi; Wang Yanfang; Xing Tao

    1995-01-01

    The paper introduces the principle of a multi-channel data acquisition system with high resolution based on the microcomputer.The system consists of five parts.They are analog-to-digital converter, data buffer area, trigger logic circuit, control circuit, and digital-to-analog converter

  8. A microprocessor based, multi-channel low-temperature monitoring system

    NARCIS (Netherlands)

    Kuiper, B.W.; van Dijk, M.H.H.

    1982-01-01

    A multi-channel low-temperature monitoring system and its design considerations are presented. The system is microprocessor based and specially designed to interface thermoresistive sensors in cryogenic experiments. The system can be easily expanded to accept any type of physical transducer and to

  9. Objective ARX Model Order Selection for Multi-Channel Human Operator Identification

    NARCIS (Netherlands)

    Roggenkämper, N; Pool, D.M.; Drop, F.M.; van Paassen, M.M.; Mulder, M.

    2016-01-01

    In manual control, the human operator primarily responds to visual inputs but may elect to make use of other available feedback paths such as physical motion, adopting a multi-channel control strategy. Hu- man operator identification procedures generally require a priori selection of the model

  10. Designing Multi-Channel Web Frameworks for Cultural Tourism Applications: The MUSE Case Study.

    Science.gov (United States)

    Garzotto, Franca; Salmon, Tullio; Pigozzi, Massimiliano

    A framework for the design of multi-channel (MC) applications in the cultural tourism domain is presented. Several heterogeneous interface devices are supported including location-sensitive mobile units, on-site stationary devices, and personalized CDs that extend the on-site experience beyond the visit time thanks to personal memories gathered…

  11. Radio frequency single electron transistors: readout for a solid state quantum computer

    International Nuclear Information System (INIS)

    Buehler, T.M.; Reilly, D.J.; Starrett, R.P.; Brenner, R.; Hamilton, A.R.; Clark, R.G.; Court, N.A.; Dzurak, A.S.

    2002-01-01

    Full text: Quantum computers promise unprecedented computational power if they can be scaled to a large number of qubits. Essential to the operation of such a machine is readout: the determination of the final quantum state of the system. In the case of the silicon based solid state architecture proposed by Kane, readout is achieved by determining the direction of a single electron spin via the detection of a spin dependent tunneling event. This requires a highly sensitive electrometer that can detect the motion of a single electron in a timescale less than the spin relaxation time. The Radio Frequency Single Electron Transistor (RF-SET) is a device that possesses both the charge sensitivity (oq ∼ 10 -6 / √Hz), approaching the quantum limit) and fast response required to perform readout in such a system. Here we describe the fabrication and operation of transmission mode RF-SETs and discuss the application of these novel electrometers in the readout of a solid state quantum computer

  12. Multi-channel amplitude analyzer CMA-1 and CMA-2

    International Nuclear Information System (INIS)

    Czermak, A.; Jablonski, J.; Ostrowicz, A.

    1977-01-01

    Analyzer CMA is implemented in the CAMAC system. A single crate contains the required modules and is controlled by the PDP-11/10 minicomputer with 8k 16 bit word memory. Spectra can be accumulated in full 4k, 2k 1k or 0,5k. System provides: display of stored data in the form of full memory, very accurate representation of any part (44 channels) on alphanumeric display, readout of the data by paper tape punch or printing. (author)

  13. Development of Multi-Channel Photoelectric Photometer Using Optical Fiber

    Directory of Open Access Journals (Sweden)

    Woo-Baik Lee

    1993-06-01

    Full Text Available We have developed a four-channel photoelectric photometer for the 61cm telescope of Sobaeksan Astronomy Observatory using optical fiber. We observed a standard star with each channel to check the efficiency difference between the channels, and found no differences. To calibrate the observing accuracy and efficiency, we have observed a short period WUMa type eclipsing binary star, BV Dra. Test observations show that the photometer is very stable and the accuracy of the data is also increased. The observing efficiency is very increased compared with that of single channel photometer; at least five times faster than older one in the case of one filter observation.

  14. Design of new multi-channel electrodes for surface electromyography signals for signal-processing.

    Science.gov (United States)

    Kilby, J; Prasad, K; Mawston, G

    2016-08-01

    This paper covers the design aspects of a new multi-channel electrode for the acquisition of surface electromyography signals from a selected muscle. The new multi-channel electrode has 11 pins where the monopolar signals produced will be configured in a software either as Linear array or Laplacian configuration. The design specification of the pre-amplifier ideally was to have a voltage gain of 500 with bandpass filtering of 5 Hz-1 kHz. The final design of the pre-amplifier circuit using an INA 118 instrumentation amplifier was built and tested to give values for voltage gain of 484 with bandpass filtering of 6.8 Hz-1.02 kHz. The software configuration that gives clearer and more defined signals in terms of motor unit action potentials for future signal processing is the Laplacian rather than Linear array.

  15. Multi-channel real time active noise control system for infant incubators.

    Science.gov (United States)

    Liu, Lichuan; Gujjula, Shruthi; Kuo, Sen M

    2009-01-01

    Excessive noise levels inside infants incubators in neonatal intensive care units (NICU) contribute to number of harmful effects on the infant's health. This paper develops and implements practical active noise control (ANC) systems for the infant incubators. The filtered-X least mean square (FXLMS) algorithm is used to cancel the noise inside the incubator. The multi-channel and pseudo multi-channel ANC systems are proposed to enhance the noise cancellation performance in terms of cancellation gain and quiet zone. An experimental setup based on real Giraffe incubator from GE Healthcare is used for real-time experiments. The results show that the ANC system can dramatically reduce the noise and cost effective.

  16. A new design for multi-channel charge to digit conversion

    International Nuclear Information System (INIS)

    Li Yong; Ai Zhujun; Su Hong; Peng Yu

    2007-01-01

    In order to improve the performance and decrease the cost of the front-end electronics readout system of the Neutron Wall Detector, a new multi-channel charge to digit conversion (QDC) circuit designed by us is introduced briefly in this paper, which mainly consists of 32 channels QAC, a judgment circuit and a A/D converter. Since new ways and new devices are adopted, the circuit features high speed of conversion, good linear, low power consumption and low cost. The multi-channel QDC circuit we developed can be widely used in nuclear measurement system of physics experiment with large-scale detector array to form front-end electronics of data acquisition system. (authors)

  17. A dynamical strategy of multi-channel MAC protocol based on QoS

    Science.gov (United States)

    Zhang, Bu-shuo; Lv, Na; Chen, Ke-fan; Zhao, Peng-bo

    2017-10-01

    Aiming at the QoS problems of QoS and channel access in aviation Ad Hoc network under high load. A multi-channel MAC protocol(DQM)based on the dynamic QoS is put forward. On the basis of statistical multi-channel detection, DQM optimizes the network traffic to ensure high priority data transmit successfully with low latency by closuring the low priority data. Aiming at ensuring the access rate of high priority data, it utilizes the flow prediction model to predict the network flow and uses the PSO to find the most optimal priority threshold .The simulation results prove that DQM maintains an optimized network traffic by adaptively controlling channel access under high load, ensures the access rate of high priority data more than 99% and solve the QoS and latency problem caused by high traffic in aviation data link.

  18. Digital baseline estimation method for multi-channel pulse height analyzing

    International Nuclear Information System (INIS)

    Xiao Wuyun; Wei Yixiang; Ai Xianyun

    2005-01-01

    The basic features of digital baseline estimation for multi-channel pulse height analysis are introduced. The weight-function of minimum-noise baseline filter is deduced with functional variational calculus. The frequency response of this filter is also deduced with Fourier transformation, and the influence of parameters on amplitude frequency response characteristics is discussed. With MATLAB software, the noise voltage signal from the charge sensitive preamplifier is simulated, and the processing effect of minimum-noise digital baseline estimation is verified. According to the results of this research, digital baseline estimation method can estimate baseline optimally, and it is very suitable to be used in digital multi-channel pulse height analysis. (authors)

  19. Non-invasive temperature monitoring using small coils during radio-frequency heating

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, Takeo; Gu, Yeun Hwa; Ushiba, Hiroaki; Hara, Kensaku; Hashimoto, Tatsuya; Nohara, Yuushi [Suzuka University, Mie (Japan); Hasegawa, Takashi [Accelerator Engineering Co, Chiba (Japan); Yamamoto, Itsuo [Yamamoto Vinyter Co, Osaka (Japan)

    1999-07-01

    In hyperthermia treatment of malignant tumors, thermal tissue injury increases drastically with every degree of increase in the tissue temperature above 42.5 .deg. C Accurate temperature monitoring during hyperthermia is important. Therefore, we developed a non-invasive method to monitor the tissue temperature during radio-frequency hyperthermia by detecting the magnetic field induced by the radio-frequency currents that flow through the heated tissue. This technique uses small multi-channel coil antennas to detect radio-frequency currents and generates two-dimensional distribution in the tissue. A rectifying circuit was connected to each coil antenna, and the current was converted with a fixed resistance into voltage. Since the voltage output from each antenna was attenuated at 1/2pr (r: distance from the radio-frequency current), single-peaked projection data were prepared, and after treatment of various signals, radio-frequency currents that flowed through the heated object were determined as a two-dimensional current distribution profile by back-projection. A high correlation was observed between the distribution of radio-frequency currents detected with the coil antennas and the temperature distribution detected by thermography. Our method of the temperature distribution suggests the possibility of non-invasive evaluation of the temperature distribution in the target of hyperthermia and clinical usefulness of this method for temperature monitoring during hyperthermia.

  20. The interface design for the USB-based multi-channel analyzer

    CERN Document Server

    Sun Guang Cai

    2002-01-01

    A new style interface circuit design for multi-channel analyzer is introduced, which takes the advantages of Universal Serial Bus to communicate with computer and gets the merit of high universality and Plug and Play. The interface circuit also uses dual-port SRAM and high-speed MCU to store and translate data, which could solve the bottleneck problem existing in data translation from the interface to computer

  1. Multi-Channel Cluster Tree for 802.15.4 Wireless Sensor Networks

    OpenAIRE

    Abdeddaim, Nazim; Theoleyre, Fabrice; Rousseau, Franck; Duda, Andrzej

    2012-01-01

    Selective A - Session: MAC12: MAC for mesh, ad hoc, relay, and sensor networks II; International audience; We propose MCCT (Multi-Channel Cluster Tree), a cluster-tree construction protocol for nodes in IEEE 802.15.4 beacon-enabled mode. By multiplexing transmissions across orthogonal channels, we reduce collisions between control and data frames, which leads to better packet delivery rate and fairness. We propose a method for constructing a cluster-tree suitable for minimizing beacon collisi...

  2. Validation of multi-channel scanning microwave radiometer on-board Oceansat-1

    Digital Repository Service at National Institute of Oceanography (India)

    Muraleedharan, P.M.; Pankajakshan, T.; Harikrishnan, M.

    the National Dairy Development Board and its subsidiary DOFCO and the Department of Biotechnology, New Delhi. NCB was supported by a Research Fellowship from the Council of Scientific and Industrial Researc h (CSIR), India. We thank A. K. Pradhan, Anil... Grover and Arun Jagannath for support with materials and helpful discussions. Received 21 February 2004; revised accepted 24 June 2004 Validation of multi - channel scanning microwave radiometer on - board Oceansat - I P. M...

  3. Asymptotically exact solution of the multi-channel resonant-level model

    International Nuclear Information System (INIS)

    Zhang Guangming; Su Zhaobin; Yu Lu.

    1994-01-01

    An asymptotically exact partition function of the multi-channel resonant-level model is obtained through Tomonaga-Luttinger bosonization. A Fermi-liquid vs. non-Fermi-liquid transition, resulting from a competition between the Kondo and X-ray edge physics, is elucidated explicitly via the renormalization group theory. In the strong-coupling limit, the model is renormalized to the Toulouse limit. (author). 20 refs, 1 fig

  4. Energy reduction using multi-channels optical wireless communication based OFDM

    Science.gov (United States)

    Darwesh, Laialy; Arnon, Shlomi

    2017-10-01

    In recent years, an increasing number of data center networks (DCNs) have been built to provide various cloud applications. Major challenges in the design of next generation DC networks include reduction of the energy consumption, high flexibility and scalability, high data rates, minimum latency and high cyber security. Use of optical wireless communication (OWC) to augment the DC network could help to confront some of these challenges. In this paper we present an OWC multi channels communication method that could lead to significant energy reduction of the communication equipment. The method is to convert a high speed serial data stream to many slower and parallel streams and vies versa at the receiver. We implement this concept of multi channels using optical orthogonal frequency division multiplexing (O-OFDM) method. In our scheme, we use asymmetrically clipped optical OFDM (ACO-OFDM). Our results show that the realization of multi channels OFDM (ACO-OFDM) methods reduces the total energy consumption exponentially, as the number of channels transmitted through them rises.

  5. Content-Based Multi-Channel Network Coding Algorithm in the Millimeter-Wave Sensor Network.

    Science.gov (United States)

    Lin, Kai; Wang, Di; Hu, Long

    2016-07-01

    With the development of wireless technology, the widespread use of 5G is already an irreversible trend, and millimeter-wave sensor networks are becoming more and more common. However, due to the high degree of complexity and bandwidth bottlenecks, the millimeter-wave sensor network still faces numerous problems. In this paper, we propose a novel content-based multi-channel network coding algorithm, which uses the functions of data fusion, multi-channel and network coding to improve the data transmission; the algorithm is referred to as content-based multi-channel network coding (CMNC). The CMNC algorithm provides a fusion-driven model based on the Dempster-Shafer (D-S) evidence theory to classify the sensor nodes into different classes according to the data content. By using the result of the classification, the CMNC algorithm also provides the channel assignment strategy and uses network coding to further improve the quality of data transmission in the millimeter-wave sensor network. Extensive simulations are carried out and compared to other methods. Our simulation results show that the proposed CMNC algorithm can effectively improve the quality of data transmission and has better performance than the compared methods.

  6. Research on development of multi-channel analyzer used for monitoring and warning radiation equipment

    International Nuclear Information System (INIS)

    Nguyen Van Sy; Dang Quang Thieu; Nguyen Thi Bao My

    2015-01-01

    The subject assigned to this paper presents research on development of multi-channel analyzer used for monitoring and warning environmental radiation equipment under the project KC.05.16/11-15 Research on manufacturing equipment monitoring and warning radiation. In this thematic we have two subjects that need to be resolved such as: i) Designing spectroscopy amplifier block (AMP) duty pulse signals obtained about few hundred millivolts output from scintillation detector preamplifier, amplified as a few volts and the standard Gaussian pulses shaped to connect to the analog-to-digital converter. The spectroscopy amplifier block can change the gain by digital control to respond to the problem of automatic spectrum stability for multi-channel analyzer systems. ii) Designing analog-to-digital converter block (ADC) in accordance with the actual conditions, such as high stability, fast conversion time, high throughput, and it consumes low energy. Selecting suitable microprocessor for fast connection ability, to operate reliably paired with the analog-to-digital converter into a multi-channel analyzer (MCA) serving analysis. (author)

  7. An Interactive Visualization Tool for Multi-channel Confocal Microscopy Data in Neurobiology Research

    Science.gov (United States)

    Wan, Yong; Otsuna, Hideo; Chien, Chi-Bin; Hansen, Charles

    2010-01-01

    Confocal microscopy is widely used in neurobiology for studying the three-dimensional structure of the nervous system. Confocal image data are often multi-channel, with each channel resulting from a different fluorescent dye or fluorescent protein; one channel may have dense data, while another has sparse; and there are often structures at several spatial scales: subneuronal domains, neurons, and large groups of neurons (brain regions). Even qualitative analysis can therefore require visualization using techniques and parameters fine-tuned to a particular dataset. Despite the plethora of volume rendering techniques that have been available for many years, the techniques standardly used in neurobiological research are somewhat rudimentary, such as looking at image slices or maximal intensity projections. Thus there is a real demand from neurobiologists, and biologists in general, for a flexible visualization tool that allows interactive visualization of multi-channel confocal data, with rapid fine-tuning of parameters to reveal the three-dimensional relationships of structures of interest. Together with neurobiologists, we have designed such a tool, choosing visualization methods to suit the characteristics of confocal data and a typical biologist’s workflow. We use interactive volume rendering with intuitive settings for multidimensional transfer functions, multiple render modes and multi-views for multi-channel volume data, and embedding of polygon data into volume data for rendering and editing. As an example, we apply this tool to visualize confocal microscopy datasets of the developing zebrafish visual system. PMID:19834225

  8. Compressed sensing MRI with multi-channel data using multi-core processors.

    Science.gov (United States)

    Chang, Ching-Hua; Ji, Jim

    2009-01-01

    Compressed sensing (CS) has emerged as a promising method in the field of magnetic resonance imaging. Taking advantage of the signal sparsity in certain domain via L(1) minimization, CS requires only reduced k-space data to reconstruct an image. Since most clinical MRI scanners are equipped with multi-channel receiver systems, integrating CS with multi-channel systems may not only shorten the scan time but provide a better image quality. However, significant computation time is required to perform CS reconstruction. Furthermore, this burden will be scaled by the number of channels. In this paper, we proposed a reconstruction procedure, which uses multi-core processors to accelerate CS reconstruction from multiple channel data. The performance was tested in terms of comparing to different image sizes and using different number cores of CPU. Experimentally, it shows that the maximum efficiency benefits from parallelizing the CS reconstructions, pipelining multi-channel data on multi-core processors and choosing the numbers of channels as multiple numbers of cores.

  9. Content-Based Multi-Channel Network Coding Algorithm in the Millimeter-Wave Sensor Network

    Directory of Open Access Journals (Sweden)

    Kai Lin

    2016-07-01

    Full Text Available With the development of wireless technology, the widespread use of 5G is already an irreversible trend, and millimeter-wave sensor networks are becoming more and more common. However, due to the high degree of complexity and bandwidth bottlenecks, the millimeter-wave sensor network still faces numerous problems. In this paper, we propose a novel content-based multi-channel network coding algorithm, which uses the functions of data fusion, multi-channel and network coding to improve the data transmission; the algorithm is referred to as content-based multi-channel network coding (CMNC. The CMNC algorithm provides a fusion-driven model based on the Dempster-Shafer (D-S evidence theory to classify the sensor nodes into different classes according to the data content. By using the result of the classification, the CMNC algorithm also provides the channel assignment strategy and uses network coding to further improve the quality of data transmission in the millimeter-wave sensor network. Extensive simulations are carried out and compared to other methods. Our simulation results show that the proposed CMNC algorithm can effectively improve the quality of data transmission and has better performance than the compared methods.

  10. An interactive visualization tool for multi-channel confocal microscopy data in neurobiology research

    KAUST Repository

    Yong Wan,

    2009-11-01

    Confocal microscopy is widely used in neurobiology for studying the three-dimensional structure of the nervous system. Confocal image data are often multi-channel, with each channel resulting from a different fluorescent dye or fluorescent protein; one channel may have dense data, while another has sparse; and there are often structures at several spatial scales: subneuronal domains, neurons, and large groups of neurons (brain regions). Even qualitative analysis can therefore require visualization using techniques and parameters fine-tuned to a particular dataset. Despite the plethora of volume rendering techniques that have been available for many years, the techniques standardly used in neurobiological research are somewhat rudimentary, such as looking at image slices or maximal intensity projections. Thus there is a real demand from neurobiologists, and biologists in general, for a flexible visualization tool that allows interactive visualization of multi-channel confocal data, with rapid fine-tuning of parameters to reveal the three-dimensional relationships of structures of interest. Together with neurobiologists, we have designed such a tool, choosing visualization methods to suit the characteristics of confocal data and a typical biologist\\'s workflow. We use interactive volume rendering with intuitive settings for multidimensional transfer functions, multiple render modes and multi-views for multi-channel volume data, and embedding of polygon data into volume data for rendering and editing. As an example, we apply this tool to visualize confocal microscopy datasets of the developing zebrafish visual system.

  11. Timing Solution and Single-pulse Properties for Eight Rotating Radio Transients

    Energy Technology Data Exchange (ETDEWEB)

    Cui, B.-Y.; McLaughlin, M. A. [Department of Physics and Astronomy West Virginia University Morgantown, WV 26506 (United States); Boyles, J. [Department of Physics and Astronomy West Kentucky University Bowling Green, KY 42101 (United States); Palliyaguru, N. [Physics and Astronomy Department Texas Tech University Lubbock, TX 79409-1051 (United States)

    2017-05-01

    Rotating radio transients (RRATs), loosely defined as objects that are discovered through only their single pulses, are sporadic pulsars that have a wide range of emission properties. For many of them, we must measure their periods and determine timing solutions relying on the timing of their individual pulses, while some of the less sporadic RRATs can be timed by using folding techniques as we do for other pulsars. Here, based on Parkes and Green Bank Telescope (GBT) observations, we introduce our results on eight RRATs including their timing-derived rotation parameters, positions, and dispersion measures (DMs), along with a comparison of the spin-down properties of RRATs and normal pulsars. Using data for 24 RRATs, we find that their period derivatives are generally larger than those of normal pulsars, independent of any intrinsic correlation with period, indicating that RRATs’ highly sporadic emission may be associated with intrinsically larger magnetic fields. We carry out Lomb–Scargle tests to search for periodicities in RRATs’ pulse detection times with long timescales. Periodicities are detected for all targets, with significant candidates of roughly 3.4 hr for PSR J1623−0841 and 0.7 hr for PSR J1839−0141. We also analyze their single-pulse amplitude distributions, finding that log-normal distributions provide the best fits, as is the case for most pulsars. However, several RRATs exhibit power-law tails, as seen for pulsars emitting giant pulses. This, along with consideration of the selection effects against the detection of weak pulses, imply that RRAT pulses generally represent the tail of a normal intensity distribution.

  12. Timing Solution and Single-pulse Properties for Eight Rotating Radio Transients

    Science.gov (United States)

    Cui, B.-Y.; Boyles, J.; McLaughlin, M. A.; Palliyaguru, N.

    2017-05-01

    Rotating radio transients (RRATs), loosely defined as objects that are discovered through only their single pulses, are sporadic pulsars that have a wide range of emission properties. For many of them, we must measure their periods and determine timing solutions relying on the timing of their individual pulses, while some of the less sporadic RRATs can be timed by using folding techniques as we do for other pulsars. Here, based on Parkes and Green Bank Telescope (GBT) observations, we introduce our results on eight RRATs including their timing-derived rotation parameters, positions, and dispersion measures (DMs), along with a comparison of the spin-down properties of RRATs and normal pulsars. Using data for 24 RRATs, we find that their period derivatives are generally larger than those of normal pulsars, independent of any intrinsic correlation with period, indicating that RRATs’ highly sporadic emission may be associated with intrinsically larger magnetic fields. We carry out Lomb-Scargle tests to search for periodicities in RRATs’ pulse detection times with long timescales. Periodicities are detected for all targets, with significant candidates of roughly 3.4 hr for PSR J1623-0841 and 0.7 hr for PSR J1839-0141. We also analyze their single-pulse amplitude distributions, finding that log-normal distributions provide the best fits, as is the case for most pulsars. However, several RRATs exhibit power-law tails, as seen for pulsars emitting giant pulses. This, along with consideration of the selection effects against the detection of weak pulses, imply that RRAT pulses generally represent the tail of a normal intensity distribution.

  13. Advanced Modular, Multi-Channel, High Speed Fiber Optic Sensing System for Acoustic Emissions Monitoring, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Intelligent Fiber Optic Systems Corporation (IFOS) proposes to prove the feasibility of innovations based on ultra-light-weight, ultra-high-speed, multi-channel,...

  14. Pixel-Wise-Inter/Intra-Channel Color and Luminance Uniformity Corrections for Multi-Channel Projection Displays

    Science.gov (United States)

    2016-08-11

    Journal Article 3. DATES COVERED (From – To) Jan 2015 – Dec 2015 4. TITLE AND SUBTITLE PIXEL-WISE INTER/INTRA-CHANNEL COLOR & LUMINANCE UNIFORMITY...Conference Dayton, Ohio – 28-29 June 2016 14. ABSTRACT Inter- and intra-channel color and luminance are generally non-uniform in multi-channel...projection display systems. Several methods have been proposed to correct for both inter- and intra-channel color and luminance variation in multi-channel

  15. A radio-frequency single-electron transistor based on an InAs/InP heterostructure nanowire

    DEFF Research Database (Denmark)

    Nilsson, Henrik A.; Duty, Tim; Abay, Simon

    2008-01-01

    We demonstrate radio frequency single-electron transistors fabricated from epitaxially grown InAs/InP heterostructure nanowires. Two sets of double-barrier wires with different barrier thicknesses were grown. The wires were suspended 15 nm above a metal gate electrode. Electrical measurements...... on a high-resistance nanowire showed regularly spaced Coulomb oscillations at a gate voltage from −0.5 to at least 1.8 V. The charge sensitivity was measured to 32 µerms Hz−1/2 at 1.5 K. A low-resistance single-electron transistor showed regularly spaced oscillations only in a small gate-voltage region just...

  16. Adaptive multi-channel downlink assignment for overloaded spectrum-shared multi-antenna overlaid cellular networks

    KAUST Repository

    Radaydeh, Redha Mahmoud

    2012-10-19

    Overlaid cellular technology has been considered as a promising candidate to enhance the capacity and extend the coverage of cellular networks, particularly indoors. The deployment of small cells (e.g. femtocells and/or picocells) in an overlaid setup is expected to reduce the operational power and to function satisfactorily with the existing cellular architecture. Among the possible deployments of small-cell access points is to manage many of them to serve specific spatial locations, while reusing the available spectrum universally. This contribution considers the aforementioned scenario with the objective to serve as many active users as possible when the available downlink spectrum is overloaded. The case study is motivated by the importance of realizing universal resource sharing in overlaid networks, while reducing the load of distributing available resources, satisfying downlink multi-channel assignment, controlling the aggregate level of interference, and maintaining desired design/operation requirements. These objectives need to be achieved in distributed manner in each spatial space with as low processing load as possible when the feedback links are capacity-limited, multiple small-cell access points can be shared, and data exchange between access points can not be coordinated. This contribution is summarized as follows. An adaptive downlink multi-channel assignment scheme when multiple co-channel and shared small-cell access points are allocated to serve active users is proposed. It is assumed that the deployed access points employ isotropic antenna arrays of arbitrary sizes, operate using the open-access strategy, and transmit on shared physical channels simultaneously. Moreover, each active user can be served by a single transmit channel per each access point at a time, and can sense the concurrent interference level associated with each transmit antenna channel non-coherently. The proposed scheme aims to identify a suitable subset of transmit channels

  17. Development of front-end readout electronics for multi-channel silicon detector

    International Nuclear Information System (INIS)

    Zhang Fei; Fan Ruirui; Peng Wenxi; Dong Yifan; Gong Ke; Wang Huanyu

    2014-01-01

    A front-end readout circuit used in charge measurement for multi-channel silicon detector and its performance test results are introduced in this paper. A 64-channel charge sensitive ASIC chip (VA140) from IDEAS company is adopted in this method. With its features of low power consumption (< 0.29 mW/ch), low noise (RMSE < O.l fC), large dynamic range (-200 fC∼ +200 fC) and high integration (include 64 channels preamplifier-shaper), it can be used in future particle detecting experiments base on silicon detector. (authors)

  18. Note: Design principles of a linear array multi-channel effusive metal-vapor atom source.

    Science.gov (United States)

    Jana, B; Majumder, A; Thakur, K B; Das, A K

    2013-10-01

    Atomic beams can easily be produced by allowing atoms to effuse through a channel. In an earlier investigation [A. Majumder et al., Vacuum 83, 989 (2009)], we had designed, fabricated, and characterized an effusive metal-vapor source using collinear-array of multi-channel. In this note, we describe the theoretical basis of designing the source. Atom density in atomic beam has been estimated using a set of analytical expressions for long-channel operated in transparent mode. Parametric studies on aspect ratio of channel, inter-channel separation, beam width, and vertical distance from the source are carried out. They are useful in providing physical picture and optimizing design parameters.

  19. On a multi-channel transportation loss system with controlled input and controlled service

    Directory of Open Access Journals (Sweden)

    Jewgeni Dshalalow

    1987-01-01

    Full Text Available A multi-channel loss queueing system is investigated. The input stream is a controlled point process. The service in each of m parallel channels depends on the state of the system at certain moments of time when input and service may be controlled. To obtain explicitly the limiting distribution of the main process (Zt (the number of busy channels in equilibrium, an auxiliary three dimensional process with two additional components (one of them is a semi-Markov process is treated as semi-regenerative process. An optimization problem is discussed. Simple expressions for an objective function are derived.

  20. Multi-channel time-division integrator in HL-2A

    International Nuclear Information System (INIS)

    Yan Ji

    2008-01-01

    HL-2A is China's first Tokamak device with divertor configuration (magnetic confinement controlled nuclear fusion device). To find out the details of on-going fusion reaction at different times is of important significance in achieving controlled nuclear fusion. We developed a new type multi-channel time-division integrator for HL-2A. It has functions of automatic cutting off negative pulse of the input signals, optional integrating time division spacing 0.2-1 ms, TTL starting trigger signal, automatic regularly work 20 s, and integrating 10 channel at the same time. (authors)

  1. Electro-optic tunable multi-channel filter in two-dimensional ferroelectric photonic crystals

    International Nuclear Information System (INIS)

    Fu, Yulan; Zhang, Jiaxiang; Hu, Xiaoyong; Gong, Qihuang

    2010-01-01

    An electro-optic tunable multi-channel filter is presented, which is based on a two-dimensional ferroelectric photonic crystal made of barium titanate. The filtering properties of the photonic crystal filter can be tuned by an applied voltage or by adjusting the structural parameters. The channel shifts about 30 nm under excitation of an applied voltage of 54.8 V. The influences of the structural disorders caused by the perturbations in the radius or the position of air holes on the filtering properties are also analyzed

  2. Design of multi-channel analyzer's monitoring system based on embedded system

    International Nuclear Information System (INIS)

    Yang Tao; Wei Yixiang

    2007-01-01

    A new Multi-Channel Analyzer's Monitoring system based on ARM9 Embedded system is introduced in this paper. Some solutions to problem are also discussed during the procedure of design, installation and debugging on Linux system. The Monitoring system is developed by using MiniGUI and Linux software system API, with the functions of collecting, displaying and I/O data controlling 1024 channels datum. They are all realized in real time, with the merits of low cost, small size and portability. All these lay the foundation of developing homemade Digital and Portable nuclear spectrometers. (authors)

  3. Frequency-comb-referenced multi-channel fiber laser for DWDM communication.

    Science.gov (United States)

    Chun, Byung Jae; Hyun, Sangwon; Kim, Seungman; Kim, Seung-Woo; Kim, Young-Jin

    2013-12-02

    We propose an all-fiber-based multi-channel optical scheme that enables simultaneous generation of multiple continuous-wave laser wavelengths with stabilization to the frequency comb of a femtosecond laser. The intention is to produce highly stable, accurate wavelength channels with immunity to environmental disturbance so as to enhance the transmission capacity of dense wavelength division multiplexing (DWDM) communications. Generated wavelengths lie over a wide spectral range of 5 THz about 1550 nm, each yielding a narrow linewidth of less than 24 kHz with an absolute position uncertainty of ~2.24 × 10¹² (10 s averaging) traceable directly to the atomic Rb clock.

  4. Characteristics of crosstalk in the reproduced output of a newly developed multi-channel MR head

    Energy Technology Data Exchange (ETDEWEB)

    Machida, K. E-mail: machida@strl.nhk.or.jp; Hayashi, N.; Yoneda, Y.; Numazawa, J.; Kohro, M.; Tanabe, T

    2001-05-01

    We prepared the multi-channel magnetoresistive head with a simple structural design and it has the advantages of high-density recording and ultra-high transfer rate. Characteristics of crosstalk in the reproduced output of our head have been estimated by a micromagnetic calculation using the Landau-Lifshitz-Gilbert (LLG) equation, while the specimen head was fabricated and evaluated. As a result, by applying a magnetic field of 40 Oe only between adjacent channels, the crosstalk was much decreased without reducing the reproduced output.

  5. Independent multi-channel analyzer with the color display and microcomputer in the CAMAC standard

    International Nuclear Information System (INIS)

    Gyunter, Z.; Elizarov, O.I.; Zhukov, G.P.; Mikhaehlis, B.; Shul'tts, K.Kh.

    1983-01-01

    An independent multi-channel time-of-flight analyzer developed for a spectrometer of polarised neutrons and used in experiments with the IBR-2 pulse reactor is described. Different cyclic modes of measuring are realized in the analyzer, 4 kwords of analyzer momory being assigned for each mode. The spectra are displayed on a colour screen during measurements. Simultaneous displaying of up to 8 spectra is possible. A microcomputer transfers the spectra from the buffer analyzer memory to the microcomputer memory. The accumulated information is transferred to the PDP-11/70 central computer

  6. Validation of multi-channel scanning microwave radiometer onboard OCEANSAT - 1

    Digital Repository Service at National Institute of Oceanography (India)

    Muraleedharan, P.M.; Pankajakshan, T.; Harikrishnan, M.

    • ~ '. :.0- Proceedings ofCOT03, International Conference on Coastal and Ocean Technology, pp. 439-443 VALIDATION OF MULTI-CHANNEL SCANNING MICROWAVE RADIOMETER ONBOARD OCEANSAT - 1. P.M.Muraleedharan and T. Pankajakshan National Institute ofOceanography, Goa.... The 150 km grid is nearest in size to the spatial resolution of the 6.6 GHz channels. All the other frequency (and polarization) channels are generated in this grid (largest grid size). Hence this grid contains the geophysical data retrieved by. making use...

  7. Multi-channel normal speed gated integrator in the measurement of the laser scattering light energy

    International Nuclear Information System (INIS)

    Yang Dong; Yu Xiaoqi; Hu Yuanfeng

    2005-01-01

    With the method of integration in a limited time, a Multi-channel normal speed gated integrator based on VXI system has been developed for measuring the signals with changeable pulse width in laser scattering light experiment. It has been tested with signal sources in ICF experiment. In tests, the integral nonlinearity between the integral results of the gated integrator and that of an oscilloscope is less than 1%. In the ICF experiments the maximum error between the integral results of the gated integrator and that of oscilloscope is less than 3% of the full scale range of the gated integrator. (authors)

  8. Applying a CPLD for Refurbishment of a Multi-channel Pulse Height Analyzer

    International Nuclear Information System (INIS)

    Leetragunpichitchai, Supalerk; Thong-Aram, Decho; Ploykrachang, Kamontip

    2007-08-01

    Full text: This research applied a CPLD for construction of a 100 MHz, 2048 channel, Wilkinson type analog to digital converter (ADC) circuits for refurbishment of an original multi-channel pulse height analyzer (PHA) ADC. Introduction of the CPLD could reduce the complexity of the circuits, equipment size and also the power consumption while the operation speed was increased. The linearity test of the ADC was found to be excellent with an R2 = 0.9995 and a maximum pulse rate of 48.828 k cps could be converted in this system. Therefore the developed system was appropriate for replacing the original ADC

  9. Network based multi-channel digital flash X-ray imaging system

    International Nuclear Information System (INIS)

    Wang Jingjin; Yuan Jie; Liu Yaqiang; Lin Yong; Song Zheng; Liu Keyin; Zhang Qi; Zheng Futang

    2000-01-01

    A network based multi-channel digital flash X-ray imaging system has been developed. It can be used to acquire and digitize orthogonal flash X-ray images in multi-interval, and to distribute the images on the network. There is no need of films and chemical process, no anxiety of waiting and no trouble of film archiving. This system is useful for testing ballistics, jet, explode, armour-piercing and fast running machines. The system composing and acquired images are presented. The software for object separating, mass calculating, 3D positioning, speed determining and cavity reconstruction are described

  10. Network based multi-channel digital flash X-ray imaging system

    International Nuclear Information System (INIS)

    Wang Jingjin; Yuan Jie; Liu Yaqiang; Lin Yong; Song Zheng; Liu Keyin

    2003-01-01

    A network based multi-channel digital flash X-ray imaging system has been developed. It can be used to acquire and digitize orthogonal flash X-ray images in multi-interval, and to distribute the images on the network. There is no need of films and chemical process, no anxiety of waiting and no trouble of film archiving. This system is useful for testing ballistics, jet, explode, armour-piercing and fast running machines. The system composing and acquired images of terminal ballistics are presented. The software for object separating, profile calculating and 3D cavity reconstruction are described

  11. Development of a USB-based multi-channel time division scaler for HL-2A

    International Nuclear Information System (INIS)

    Liang Ping

    2008-01-01

    HL-2A is China's first Tokamak device with divertor configuration. Mastering the process and plasma parameter changes with time are of great significance to achieve controlled nuclear fusion. In the recent upgrading of HL-2A, for which a higher and faster electronic equipment was required, we developed a new type USB multi-channel time division scaler for HL-2A including functions: USB interface, PC graphical user interface, simultaneously calibrating more than five channel signals, optional time division spacing 2-50 ms, count rate up to over 2 MHz, accessing all the information 20 s after a activated signal, and processing data and displaying off-line. (authors)

  12. Dual-Stack Single-Radio Communication Architecture for UAV Acting As a Mobile Node to Collect Data in WSNs

    Directory of Open Access Journals (Sweden)

    Ali Sayyed

    2015-09-01

    Full Text Available The use of mobile nodes to collect data in a Wireless Sensor Network (WSN has gained special attention over the last years. Some researchers explore the use of Unmanned Aerial Vehicles (UAVs as mobile node for such data-collection purposes. Analyzing these works, it is apparent that mobile nodes used in such scenarios are typically equipped with at least two different radio interfaces. The present work presents a Dual-Stack Single-Radio Communication Architecture (DSSRCA, which allows a UAV to communicate in a bidirectional manner with a WSN and a Sink node. The proposed architecture was specifically designed to support different network QoS requirements, such as best-effort and more reliable communications, attending both UAV-to-WSN and UAV-to-Sink communications needs. DSSRCA was implemented and tested on a real UAV, as detailed in this paper. This paper also includes a simulation analysis that addresses bandwidth consumption in an environmental monitoring application scenario. It includes an analysis of the data gathering rate that can be achieved considering different UAV flight speeds. Obtained results show the viability of using a single radio transmitter for collecting data from the WSN and forwarding such data to the Sink node.

  13. Dual-Stack Single-Radio Communication Architecture for UAV Acting As a Mobile Node to Collect Data in WSNs.

    Science.gov (United States)

    Sayyed, Ali; de Araújo, Gustavo Medeiros; Bodanese, João Paulo; Becker, Leandro Buss

    2015-09-16

    The use of mobile nodes to collect data in a Wireless Sensor Network (WSN) has gained special attention over the last years. Some researchers explore the use of Unmanned Aerial Vehicles (UAVs) as mobile node for such data-collection purposes. Analyzing these works, it is apparent that mobile nodes used in such scenarios are typically equipped with at least two different radio interfaces. The present work presents a Dual-Stack Single-Radio Communication Architecture (DSSRCA), which allows a UAV to communicate in a bidirectional manner with a WSN and a Sink node. The proposed architecture was specifically designed to support different network QoS requirements, such as best-effort and more reliable communications, attending both UAV-to-WSN and UAV-to-Sink communications needs. DSSRCA was implemented and tested on a real UAV, as detailed in this paper. This paper also includes a simulation analysis that addresses bandwidth consumption in an environmental monitoring application scenario. It includes an analysis of the data gathering rate that can be achieved considering different UAV flight speeds. Obtained results show the viability of using a single radio transmitter for collecting data from the WSN and forwarding such data to the Sink node.

  14. Reduced-complexity adaptive multi-channel assignment for shared access points in over-loaded small-cell networks

    KAUST Repository

    Radaydeh, Redha Mahmoud

    2013-06-01

    This paper proposes a reduced-complexity downlink multi-channel assignment scheme when feedback links are capacity-limited. The system model treats the case when multiple access points are allocated to serve scheduled users in over-loaded (i.e. dense) pico/femtocell networks. It assumes that the deployed access points can be shared simultaneously and employ isotropic antenna arrays of arbitrary sizes. Moreover, they transmit their data on a common physical channel and can not coordinate their transmissions. On the other hand, each scheduled user can be served by single transmit channel from each active access point at a time, and it lacks coordination with concurrent active users. The scheme operates according to the occupancy of available transmit channels, wherein extensively occupied access points are avoided adaptively, while reducing the load of processing. The operation is linked to a target performance via controlling the observed aggregate interference from the projected set of serving points. Through the analysis, results for the scheduled user outage performance, and the average number of active access points are presented. Numerical and simulations studies clarify the gains of the proposed scheme for different operating conditions. © 2013 IEEE.

  15. Spectrum-efficient multi-channel design for coexisting IEEE 802.15.4 networks: A stochastic geometry approach

    KAUST Repository

    Elsawy, Hesham

    2014-07-01

    For networks with random topologies (e.g., wireless ad-hoc and sensor networks) and dynamically varying channel gains, choosing the long term operating parameters that optimize the network performance metrics is very challenging. In this paper, we use stochastic geometry analysis to develop a novel framework to design spectrum-efficient multi-channel random wireless networks based on the IEEE 802.15.4 standard. The proposed framework maximizes both spatial and time domain frequency utilization under channel gain uncertainties to minimize the number of frequency channels required to accommodate a certain population of coexisting IEEE 802.15.4 networks. The performance metrics are the outage probability and the self admission failure probability. We relax the single channel assumption that has been used traditionally in the stochastic geometry analysis. We show that the intensity of the admitted networks does not increase linearly with the number of channels and the rate of increase of the intensity of the admitted networks decreases with the number of channels. By using graph theory, we obtain the minimum required number of channels to accommodate a certain intensity of coexisting networks under a self admission failure probability constraint. To this end, we design a superframe structure for the coexisting IEEE 802.15.4 networks and a method for time-domain interference alignment. © 2002-2012 IEEE.

  16. A reconfigurable microwave photonic filter with flexible tunability using a multi-wavelength laser and a multi-channel phase-shifted fiber Bragg grating

    Science.gov (United States)

    Shi, Nuannuan; Hao, Tengfei; Li, Wei; Zhu, Ninghua; Li, Ming

    2018-01-01

    We propose a photonic scheme to realize a reconfigurable microwave photonic filter (MPF) with flexible tunability using a multi-wavelength laser (MWL) and a multi-channel phase-shifted fiber Bragg grating (PS-FBG). The proposed MPF is capable of performing reconfigurability including single bandpass filter, two independently bandpass filter and a flat-top bandpass filter. The performance such as the central frequency and the bandwidth of passband is tuned by controlling the wavelengths of the MWL. In the MPF, The light waves from a MWL are sent to a phase modulator (PM) to generate the phase-modulated optical signals. By applying a multi-channel PS-FBG, which has a series of narrow notches in the reflection spectrum with the free spectral range (FSR) of 0.8 nm, the +1st sidebands are removed in the notches and the phased-modulated signals are converted to the intensity-modulated signals without beating signals generation between each two optical carriers. The proposed MPF is also experimentally verified. The 3-dB bandwidth of the MPF is broadened from 35 MHz to 135 MHz and the magnitude deviation of the top from the MPF is less than 0.2 dB within the frequency tunable range from 1 GHz to 5 GHz.

  17. Multi-channel control circuit for real-time control of events in Aditya tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Edappala, Praveenlal, E-mail: praveen@ipr.res.in; Shah, Minsha; Rajpal, Rachana; Tanna, R.L.; Ghosh, Joydeep; Chattopadhyay, P.K.; Jha, R.

    2016-11-15

    Highlights: • Low cost microcontroller based control circuit. • The control hardware can be programmed/configured very easily for different applications. • Microcontroller programming is done in assembly language so that precise timing can be achieved with micro seconds resolution. • Successful implementation of this circuit in noisy tokamak environment. • Efficient noise and burst elimination. • Can be integrated in to the other subsystems. • Low cost solution for implementing feedback control in small and medium size tokamaks and other experiments requiring feedback control. - Abstract: Tokamak plasma is prone to many random events having potential for causing severe damages to the machine, such as disruptions, production and elimination of high-energy runaway electrons etc. These events can be mitigated by obtaining pre-cursor signal leading to these events and then taking proper measures just before their onset to avoid their happenings, like disruptions can be mitigated by massive gas injection or putting a bias voltage on an electrode placed inside the plasma, the runaways can be mitigated by gas injection and by applying specific magnetic fields. Hence for real time control of these events, the pre-cursors should be electronically recorded and the mitigation techniques should be initiated by sending triggers to their individual operational systems. To implement these methodologies of real-time controlling of events in Aditya Tokamak, a low cost multi-channel Micro-Controller based timing circuit is designed and developed in-house. This circuit first compares the precursor signals fed into it with the pre-set values and gives a trigger output whenever the signals overshoot the pre-set values. The circuit readies itself for operation along with start of the tokamak discharge and waits up to an initial pre-determined delay and then initiates a trigger at the time of overshooting of precursor signal. The circuit is fully integrated and assembled in

  18. A modified multi-channel EMG feature for upper limb motion pattern recognition.

    Science.gov (United States)

    Tsai, An-Chih; Luh, Jer-Junn; Lin, Ta-Te

    2012-01-01

    The EMG signal is a well-known and useful biomedical signal. Much information related to muscles and human motions is included in EMG signals. Many approaches have proposed various methods that tried to recognize human motion via EMG signals. However, one of the critical problems of motion pattern recognition is that the performance of recognition is easily affected by the normalization procedure and may not work well on different days. In this paper, a modified feature of the multi-channel EMG signal is proposed and the normalization procedure is also simplified by using this modified feature. To recognize motion pattern, we applied the support vector machine (SVM) to build the motion pattern recognition model. In training and validation procedures, we used the 2-DoF exoskeleton robot arm system to do the designed pose, and the multi-channel EMG signals were obtained while the user resisted the robot. Experiment results indicate that the performance of applying the proposed feature (94.9%) is better than that of conventional features. Moreover, the performances of the recognition model, which applies the modified feature to recognize the motions on different days, are more stable than other conventional features.

  19. An Efficient VLSI Architecture for Multi-Channel Spike Sorting Using a Generalized Hebbian Algorithm

    Directory of Open Access Journals (Sweden)

    Ying-Lun Chen

    2015-08-01

    Full Text Available A novel VLSI architecture for multi-channel online spike sorting is presented in this paper. In the architecture, the spike detection is based on nonlinear energy operator (NEO, and the feature extraction is carried out by the generalized Hebbian algorithm (GHA. To lower the power consumption and area costs of the circuits, all of the channels share the same core for spike detection and feature extraction operations. Each channel has dedicated buffers for storing the detected spikes and the principal components of that channel. The proposed circuit also contains a clock gating system supplying the clock to only the buffers of channels currently using the computation core to further reduce the power consumption. The architecture has been implemented by an application-specific integrated circuit (ASIC with 90-nm technology. Comparisons to the existing works show that the proposed architecture has lower power consumption and hardware area costs for real-time multi-channel spike detection and feature extraction.

  20. Wireless acquisition of multi-channel seismic data using the Seismobile system

    Science.gov (United States)

    Isakow, Zbigniew

    2017-11-01

    This paper describes the wireless acquisition of multi-channel seismic data using a specialized mobile system, Seismobile, designed for subsoil diagnostics for transportation routes. The paper presents examples of multi-channel seismic records obtained during system tests in a configuration with 96 channels (4 landstreamers of 24-channel) and various seismic sources. Seismic waves were generated at the same point using different sources: a 5-kg hammer, a Gisco's source with a 90-kg pile-driver, and two other the pile-drivers of 45 and 70 kg. Particular attention is paid to the synchronization of source timing, the measurement of geometry by autonomous GPS systems, and the repeatability of triggering measurements constrained by an accelerometer identifying the seismic waveform. The tests were designed to the registration, reliability, and range of the wireless transmission of survey signals. The effectiveness of the automatic numbering of measuring modules was tested as the system components were arranged and fixed to the streamers. After measurements were completed, the accuracy and speed of data downloading from the internal memory (SDHC 32GB WiFi) was determined. Additionally, the functionality of automatic battery recharging, the maximum survey duration, and the reliability of battery discharge signalling were assessed.

  1. Analysis and compensation of synchronous measurement error for multi-channel laser interferometer

    International Nuclear Information System (INIS)

    Du, Shengwu; Hu, Jinchun; Zhu, Yu; Hu, Chuxiong

    2017-01-01

    Dual-frequency laser interferometer has been widely used in precision motion system as a displacement sensor, to achieve nanoscale positioning or synchronization accuracy. In a multi-channel laser interferometer synchronous measurement system, signal delays are different in the different channels, which will cause asynchronous measurement, and then lead to measurement error, synchronous measurement error (SME). Based on signal delay analysis of the measurement system, this paper presents a multi-channel SME framework for synchronous measurement, and establishes the model between SME and motion velocity. Further, a real-time compensation method for SME is proposed. This method has been verified in a self-developed laser interferometer signal processing board (SPB). The experiment result showed that, using this compensation method, at a motion velocity 0.89 m s −1 , the max SME between two measuring channels in the SPB is 1.1 nm. This method is more easily implemented and applied to engineering than the method of directly testing smaller signal delay. (paper)

  2. Analysis and compensation of synchronous measurement error for multi-channel laser interferometer

    Science.gov (United States)

    Du, Shengwu; Hu, Jinchun; Zhu, Yu; Hu, Chuxiong

    2017-05-01

    Dual-frequency laser interferometer has been widely used in precision motion system as a displacement sensor, to achieve nanoscale positioning or synchronization accuracy. In a multi-channel laser interferometer synchronous measurement system, signal delays are different in the different channels, which will cause asynchronous measurement, and then lead to measurement error, synchronous measurement error (SME). Based on signal delay analysis of the measurement system, this paper presents a multi-channel SME framework for synchronous measurement, and establishes the model between SME and motion velocity. Further, a real-time compensation method for SME is proposed. This method has been verified in a self-developed laser interferometer signal processing board (SPB). The experiment result showed that, using this compensation method, at a motion velocity 0.89 m s-1, the max SME between two measuring channels in the SPB is 1.1 nm. This method is more easily implemented and applied to engineering than the method of directly testing smaller signal delay.

  3. SVM-Based Spectral Analysis for Heart Rate from Multi-Channel WPPG Sensor Signals

    Directory of Open Access Journals (Sweden)

    Jiping Xiong

    2017-03-01

    Full Text Available Although wrist-type photoplethysmographic (hereafter referred to as WPPG sensor signals can measure heart rate quite conveniently, the subjects’ hand movements can cause strong motion artifacts, and then the motion artifacts will heavily contaminate WPPG signals. Hence, it is challenging for us to accurately estimate heart rate from WPPG signals during intense physical activities. The WWPG method has attracted more attention thanks to the popularity of wrist-worn wearable devices. In this paper, a mixed approach called Mix-SVM is proposed, it can use multi-channel WPPG sensor signals and simultaneous acceleration signals to measurement heart rate. Firstly, we combine the principle component analysis and adaptive filter to remove a part of the motion artifacts. Due to the strong relativity between motion artifacts and acceleration signals, the further denoising problem is regarded as a sparse signals reconstruction problem. Then, we use a spectrum subtraction method to eliminate motion artifacts effectively. Finally, the spectral peak corresponding to heart rate is sought by an SVM-based spectral analysis method. Through the public PPG database in the 2015 IEEE Signal Processing Cup, we acquire the experimental results, i.e., the average absolute error was 1.01 beat per minute, and the Pearson correlation was 0.9972. These results also confirm that the proposed Mix-SVM approach has potential for multi-channel WPPG-based heart rate estimation in the presence of intense physical exercise.

  4. Design and fabricate multi channel microfluidic mold on top of glass slide using SU-8

    Science.gov (United States)

    Azman, N. A. N.; Rajapaksha, R. D. A. A.; Uda, M. N. A.; Hashim, U.

    2017-09-01

    Microfluidic is the study of fluid in microscale. Microfluidics provides miniaturized fluidic networks for processing and analyzing liquids in the nanoliter to milliliter range. Microfluidic device comprises of some essential segments or structure that are micromixer, microchannel and microchamber. The SU-8 mold is known as the most used technique in microfluidic fabrication due to the characteristic of very gooey polymer that can be spread over a thickness. In this study, in order to reduce the fabrication cost, the development and fabrication of SU-8 mold is replace by using a glass plate instead of silicon wafer which is used in the previous research. We designed a microfluidic chip for use with an IDE sensors to conduct multiplex detection of multiple channels. The microfluidic chip was designed to include multiplex detection for pathogen that consists of multiple channels of simultaneous results. The multi-channel microfluidic chip was designed, including the fluid outlet and inlet. A multi-channel microfluidic chip was used for pathogen detection. This paper sum up the fabrication of lab SU-8 mold using glass slide.

  5. Adaptation of the Electra Radio to Support Multiple Receive Channels

    Science.gov (United States)

    Satorius, Edgar H.; Shah, Biren N.; Bruvold, Kristoffer N.; Bell, David J.

    2011-01-01

    Proposed future Mars missions plan communication between multiple assets (rovers). This paper presents the results of a study carried out to assess the potential adaptation of the Electra radio to a multi-channel transceiver. The basic concept is a Frequency Division multiplexing (FDM) communications scheme wherein different receiver architectures are examined. Options considered include: (1) multiple IF slices, A/D and FPGAs each programmed with an Electra baseband modem; (2) common IF but multiple A/Ds and FPGAs and (3) common IF, single A/D and single or multiple FPGAs programmed to accommodate the FDM signals. These options represent the usual tradeoff between analog and digital complexity. Given the space application, a common IF is preferable; however, multiple users present dynamic range challenges (e.g., near-far constraints) that would favor multiple IF slices (Option 1). Vice versa, with a common IF and multiple A/Ds (Option 2), individual AGC control of the A/Ds would be an important consideration. Option 3 would require a common AGC control strategy and would entail multiple digital down conversion paths within the FPGA. In this paper, both FDM parameters as well as the different Electra design options will be examined. In particular, signal channel spacing as a function of user data rates and transmit powers will be evaluated. In addition, tradeoffs between the different Electra design options will be presented with the ultimate goal of defining an augmented Electra radio architecture for potential future missions.

  6. The influence of ocean conditions on two-phase flow instability in a parallel multi-channel system

    International Nuclear Information System (INIS)

    Yun Guo; Qiu, S.Z.; Su, G.H.; Jia, D.N.

    2008-01-01

    In this paper, the two-phase flow instability between multi-channels (FIBM) operating under ocean conditions is studied theoretically. The physical and mathematical model of the multi-channel system which is based on Lee and Pan [Lee, J.D., Pan, C., 1999. Dynamics of multiple parallel boiling channel systems with forced flows. Nuclear Engineering and Design 192, 31-44], is extended to analyze the influence of ocean conditions. The influence of ocean conditions on the FIBM is analyzed, particularly with respect to the periodic total mass flow rate and rolling motion. Furthermore, the instability oscillation trajectories of the multi-channel system are obtained on the phase plane of the inlet velocity and boiling boundary. Some of the trajectories show chaotic characteristic. The instability zone of a nine-channel system under rolling motion is then obtained

  7. The designing principle and implementation of multi-channel intelligence isotope thickness gauge based on multifunction card PCI-1710

    International Nuclear Information System (INIS)

    Zhang Bin; Zhao Shujun; Guo Maotian; He Jintian

    2006-01-01

    The designing principle, the constitution of system and the implementation of multi-channel intelligence isotope thickness gauge are introduced in the paper in detail, which are based on multifunction card PCI-1710. The paper also discusses the primaryprinciple of isotope thickness gauge, correct factor in measurement and complication of calibration. In the following, the whole frame of multi-channel intelligence isotope thickness gauge is given. The functions, the characteristics and the usage of multifunction card PCI-1710 are described. Furthermore, the developing process and the function modules of software are presented. Finally, the real prototype of multi-channel intelligence isotope thickness gauge is introduced, using 241 Am as a radioactive element. (authors)

  8. A miniaturized NQR spectrometer for a multi-channel NQR-based detection device.

    Science.gov (United States)

    Beguš, Samo; Jazbinšek, Vojko; Pirnat, Janez; Trontelj, Zvonko

    2014-10-01

    A low frequency (0.5-5 MHz) battery operated sensitive pulsed NQR spectrometer with a transmitter power up to 5 W and a total mass of about 3 kg aimed at detecting (14)N NQR signals, predominantly of illicit materials, was designed and assembled. This spectrometer uses a standard software defined radio (SDR) platform for the data acquisition unit. Signal processing is done with the LabView Virtual instrument on a personal computer. We successfully tested the spectrometer by measuring (14)N NQR signals from aminotetrazole monohydrate (ATMH), potassium nitrate (PN), paracetamol (PCM) and trinitrotoluene (TNT). Such a spectrometer is a feasible component of a portable single or multichannel (14)N NQR based detection device. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Flexible Method for the Automated Offline-Detection of Artifacts in Multi-Channel Electroencephalogram Recordings

    DEFF Research Database (Denmark)

    Waser, Markus; Garn, Heinrich; Benke, Thomas

    2017-01-01

    . However, these preprocessing steps do not allow for complete artifact correction. We propose a method for the automated offline-detection of remaining artifacts after preprocessing in multi-channel EEG recordings. In contrast to existing methods it requires neither adaptive parameters varying between...... recordings nor a topography template. It is suited for short EEG segments and is flexible with regard to target applications. The algorithm was developed and tested on 60 clinical EEG samples of 20 seconds each that were recorded both in resting state and during cognitive activation to gain a realistic...... in conjunction with receiver operating characteristics (ROC curves). We observed high sensitivity of 95.5%±4.8 and specificity of 88.8%±2.1. The method has thus shown great potential and is promising as a possible tool for both EEG-based clinical applications and EEG-related research....

  10. Mathematical modeling of fluid flow in complex multi-channel structures

    Science.gov (United States)

    Shashkin, V. Y.

    2017-10-01

    The work is focused on a numerical hydraulic model, which allows one to simulate fluid flow in a complex, arbitrarily configured multi-channel system with a capability of automatic visualization of its structure. The main elements of a system are channels which are united in the system by means of a particular set of coupling elements (local resistance, knots). The processes models in channels are based on the equation of continuity, momentum conservation. The system structure is made by forming matrices of regional and internal boundary conditions according to the developed algorithm. By the model the algorithm is created, on the basis of which the application program is developed. The application program enables one to determine parameters of a steady state of fluid flow in the complex multichannel structures. The calculation structure is shown.

  11. [Analysis of the Muscle Fatigue Based on Band Spectrum Entropy of Multi-channel Surface Electromyography].

    Science.gov (United States)

    Liu, Jian; Zou, Renling; Zhang, Dongheng; Xu, Xiulin; Hu, Xiufang

    2016-06-01

    Exercise-induced muscle fatigue is a phenomenon that the maximum voluntary contraction force or power output of muscle is temporarily reduced due to muscular movement.If the fatigue is not treated properly,it will bring about a severe injury to the human body.With multi-channel collection of lower limb surface electromyography signals,this article analyzes the muscle fatigue by adoption of band spectrum entropy method which combined electromyographic signal spectral analysis and nonlinear dynamics.The experimental result indicated that with the increase of muscle fatigue,muscle signal spectrum began to move to low frequency,the energy concentrated,the system complexity came down,and the band spectrum entropy which reflected the complexity was also reduced.By monitoring the entropy,we can measure the degree of muscle fatigue,and provide an indicator to judge fatigue degree for the sports training and clinical rehabilitation training.

  12. Design of a novel multi channel photonic crystal fiber polarization beam splitter

    Science.gov (United States)

    Zhao, Yunyan; Li, Shuguang; Wang, Xinyu; Wang, Guangyao; Shi, Min; Wu, Junjun

    2017-10-01

    A kind of multi channel dual-core photonic crystal fiber polarization beam splitter is designed. We analyze the effects of the lattice parameters and the thickness of gold layer on the beam splitting by the finite element method. Numerical results show that the thickness of metal layer and the size of the air holes near the fiber cores are closely linked with the nature of the polarization beam splitter. We also obtain that extinction ratio can reach -73.87 dB at 1 . 55 μm wavelength and at 1 . 41 μm, 1 . 65 μm extinction ratio can reach 30.8978 dB and 31.1741 dB, respectively. The comparison of the effect on the characteristic of the photonic crystal fiber with coating no gold is also taken into account.

  13. A low delay transmission method of multi-channel video based on FPGA

    Science.gov (United States)

    Fu, Weijian; Wei, Baozhi; Li, Xiaobin; Wang, Quan; Hu, Xiaofei

    2018-03-01

    In order to guarantee the fluency of multi-channel video transmission in video monitoring scenarios, we designed a kind of video format conversion method based on FPGA and its DMA scheduling for video data, reduces the overall video transmission delay.In order to sace the time in the conversion process, the parallel ability of FPGA is used to video format conversion. In order to improve the direct memory access (DMA) writing transmission rate of PCIe bus, a DMA scheduling method based on asynchronous command buffer is proposed. The experimental results show that this paper designs a low delay transmission method based on FPGA, which increases the DMA writing transmission rate by 34% compared with the existing method, and then the video overall delay is reduced to 23.6ms.

  14. Selecting participants for listening tests of multi-channel reproduced sound

    DEFF Research Database (Denmark)

    Wickelmaier, Florian; Choisel, Sylvain

    2005-01-01

    A selection procedure was devised in order to select listeners for experiments in which their main task will be to judge multi-channel reproduced sound. 91 participants filled in a web-based questionnaire. 78 of them took part in an assessment of their hearing thresholds, their spatial hearing......, and their verbal production abilities. The listeners displayed large individual differences in their performance. 40 subjects were selected based on the test results. The self-assessed listening habits and experience in the web questionnaire could not predict the results of the selection procedure. Further......, the hearing thresholds did not correlate with the spatial-hearing test. This leads to the conclusion that task-specific performance tests might be the preferable means of selecting a listening panel....

  15. Research on Intelligent Control System of DC SQUID Magnetometer Parameters for Multi-channel System

    Science.gov (United States)

    Chen, Hua; Yang, Kang; Lu, Li; Kong, Xiangyan; Wang, Hai; Wu, Jun; Wang, Yongliang

    2018-03-01

    In a multi-channel SQUID measurement system, adjusting device parameters to optimal condition for all channels is time-consuming. In this paper, an intelligent control system is presented to determine the optimal working point of devices which is automatic and more efficient comparing to the manual one. An optimal working point searching algorithm is introduced as the core component of the control system. In this algorithm, the bias voltage V_bias is step scanned to obtain the maximal value of the peak-to-peak current value I_pp of the SQUID magnetometer modulation curve. We choose this point as the optimal one. Using the above control system, more than 30 weakly damped SQUID magnetometers with area of 5 × 5 mm^2 or 10 × 10 mm^2 are adjusted and a 36-channel magnetocardiography system perfectly worked in a magnetically shielded room. The average white flux noise is 15 μΦ_0/Hz^{1/2}.

  16. Signal Detection of Multi-Channel Capillary Electrophoresis Chip Based on CCD

    Science.gov (United States)

    Lv, Hongfeng; Yan, Weiping; Yang, Xiaobo; Li, Jiechao; Zhu, Jieying

    2012-12-01

    A kind of multi-channel capillary electrophoresis (CE) chip signal detection system based on CCD was developed. The output signal of the CCD sensor was processed by a series of pre-processing circuits and ADC, and then it was collected by the Field Programmable Gate Array (FPGA) chip which communicated with a host computer. The core in FPGA was designed to control the signal flow of the CCD and transfer the data to PC based on a Nios II embedded soft-processor. The application of PC was used to store the data and demonstrate the curve. The measurement of the fluorescent signals for different concentration Rhodamine B dyes is presented and the comparison with other detection systems is also discussed.

  17. A customizable multi-channel loudness compensation method based on WDRC for digital hearing aids

    Science.gov (United States)

    Hu, Jiebin; Wang, Mingjiang; Ma, Min

    2017-08-01

    Loudness compensation is the most significant signal processing algorithm in digital hearing aids at present. An algorithm of multi-channel loudness compensation for embedded system has been put forward in this paper. The number of channels is customizable in this algorithm. The algorithm can set different number and different width of channels for each patient based on frequency domain wide dynamic range compression. First, according to the requirement of patient to divide the frequency domain into multiple unequal frequency bands. And then calculate the gain of each channel according to the input-output curve of sound pressure level. Finally, the time-domain impulse response of gain is computed from Mel filter banks. It is used in conjunction with speech enhancement processing in hearing aids. Simulation results show that the algorithm can effectively enhance the loudness for different frequencies.

  18. Multi-channel, passive, short-range anti-aircraft defence system

    Science.gov (United States)

    Gapiński, Daniel; Krzysztofik, Izabela; Koruba, Zbigniew

    2018-01-01

    The paper presents a novel method for tracking several air targets simultaneously. The developed concept concerns a multi-channel, passive, short-range anti-aircraft defence system based on the programmed selection of air targets and an algorithm of simultaneous synchronisation of several modified optical scanning seekers. The above system is supposed to facilitate simultaneous firing of several self-guided infrared rocket missiles at many different air targets. From the available information, it appears that, currently, there are no passive self-guided seekers that fulfil such tasks. This paper contains theoretical discussions and simulations of simultaneous detection and tracking of many air targets by mutually integrated seekers of several rocket missiles. The results of computer simulation research have been presented in a graphical form.

  19. Electro-opto-mechanical radio-frequency oscillator driven by guided acoustic waves in standard single-mode fiber

    Directory of Open Access Journals (Sweden)

    Yosef London

    2017-04-01

    Full Text Available An opto-electronic radio-frequency oscillator that is based on forward scattering by the guided acoustic modes of a standard single-mode optical fiber is proposed and demonstrated. An optical pump wave is used to stimulate narrowband, resonant guided acoustic modes, which introduce phase modulation to a co-propagating optical probe wave. The phase modulation is converted to an intensity signal at the output of a Sagnac interferometer loop. The intensity waveform is detected, amplified, and driven back to modulate the optical pump. Oscillations are achieved at a frequency of 319 MHz, which matches the resonance of the acoustic mode that provides the largest phase modulation of the probe wave. Oscillations at the frequencies of competing acoustic modes are suppressed by at least 40 dB. The linewidth of the acoustic resonance is sufficiently narrow to provide oscillations at a single longitudinal mode of the hybrid cavity. Competing longitudinal modes are suppressed by at least 38 dB as well. Unlike other opto-electronic oscillators, no radio-frequency filtering is required within the hybrid cavity. The frequency of oscillations is entirely determined by the fiber opto-mechanics.

  20. Scale-Free Brain Quartet: Artistic Filtering of Multi-Channel Brainwave Music

    Science.gov (United States)

    Wu, Dan; Li, Chaoyi; Yao, Dezhong

    2013-01-01

    To listen to the brain activities as a piece of music, we proposed the scale-free brainwave music (SFBM) technology, which translated scalp EEGs into music notes according to the power law of both EEG and music. In the present study, the methodology was extended for deriving a quartet from multi-channel EEGs with artistic beat and tonality filtering. EEG data from multiple electrodes were first translated into MIDI sequences by SFBM, respectively. Then, these sequences were processed by a beat filter which adjusted the duration of notes in terms of the characteristic frequency. And the sequences were further filtered from atonal to tonal according to a key defined by the analysis of the original music pieces. Resting EEGs with eyes closed and open of 40 subjects were utilized for music generation. The results revealed that the scale-free exponents of the music before and after filtering were different: the filtered music showed larger variety between the eyes-closed (EC) and eyes-open (EO) conditions, and the pitch scale exponents of the filtered music were closer to 1 and thus it was more approximate to the classical music. Furthermore, the tempo of the filtered music with eyes closed was significantly slower than that with eyes open. With the original materials obtained from multi-channel EEGs, and a little creative filtering following the composition process of a potential artist, the resulted brainwave quartet opened a new window to look into the brain in an audible musical way. In fact, as the artistic beat and tonal filters were derived from the brainwaves, the filtered music maintained the essential properties of the brain activities in a more musical style. It might harmonically distinguish the different states of the brain activities, and therefore it provided a method to analyze EEGs from a relaxed audio perspective. PMID:23717527

  1. Estimation of black carbon content for biomass burning aerosols from multi-channel Raman lidar data

    Science.gov (United States)

    Talianu, Camelia; Marmureanu, Luminita; Nicolae, Doina

    2015-04-01

    Biomass burning due to natural processes (forest fires) or anthropical activities (agriculture, thermal power stations, domestic heating) is an important source of aerosols with a high content of carbon components (black carbon and organic carbon). Multi-channel Raman lidars provide information on the spectral dependence of the backscatter and extinction coefficients, embedding information on the black carbon content. Aerosols with a high content of black carbon have large extinction coefficients and small backscatter coefficients (strong absorption), while aerosols with high content of organic carbon have large backscatter coefficients (weak absorption). This paper presents a method based on radiative calculations to estimate the black carbon content of biomass burning aerosols from 3b+2a+1d lidar signals. Data is collected at Magurele, Romania, at the cross-road of air masses coming from Ukraine, Russia and Greece, where burning events are frequent during both cold and hot seasons. Aerosols are transported in the free troposphere, generally in the 2-4 km altitude range, and reaches the lidar location after 2-3 days. Optical data are collected between 2011-2012 by a multi-channel Raman lidar and follows the quality assurance program of EARLINET. Radiative calculations are made with libRadTran, an open source radiative model developed by ESA. Validation of the retrievals is made by comparison to a co-located C-ToF Aerosol Mass Spectrometer. Keywords: Lidar, aerosols, biomass burning, radiative model, black carbon Acknowledgment: This work has been supported by grants of the Romanian National Authority for Scientific Research, Programme for Research- Space Technology and Advanced Research - STAR, project no. 39/2012 - SIAFIM, and by Romanian Partnerships in priority areas PNII implemented with MEN-UEFISCDI support, project no. 309/2014 - MOBBE

  2. Scale-free brain quartet: artistic filtering of multi-channel brainwave music.

    Science.gov (United States)

    Wu, Dan; Li, Chaoyi; Yao, Dezhong

    2013-01-01

    To listen to the brain activities as a piece of music, we proposed the scale-free brainwave music (SFBM) technology, which translated scalp EEGs into music notes according to the power law of both EEG and music. In the present study, the methodology was extended for deriving a quartet from multi-channel EEGs with artistic beat and tonality filtering. EEG data from multiple electrodes were first translated into MIDI sequences by SFBM, respectively. Then, these sequences were processed by a beat filter which adjusted the duration of notes in terms of the characteristic frequency. And the sequences were further filtered from atonal to tonal according to a key defined by the analysis of the original music pieces. Resting EEGs with eyes closed and open of 40 subjects were utilized for music generation. The results revealed that the scale-free exponents of the music before and after filtering were different: the filtered music showed larger variety between the eyes-closed (EC) and eyes-open (EO) conditions, and the pitch scale exponents of the filtered music were closer to 1 and thus it was more approximate to the classical music. Furthermore, the tempo of the filtered music with eyes closed was significantly slower than that with eyes open. With the original materials obtained from multi-channel EEGs, and a little creative filtering following the composition process of a potential artist, the resulted brainwave quartet opened a new window to look into the brain in an audible musical way. In fact, as the artistic beat and tonal filters were derived from the brainwaves, the filtered music maintained the essential properties of the brain activities in a more musical style. It might harmonically distinguish the different states of the brain activities, and therefore it provided a method to analyze EEGs from a relaxed audio perspective.

  3. A radio frequency single-electron transistor based on an InAs/InP heterostructure nanowire.

    Science.gov (United States)

    Nilsson, Henrik A; Duty, Tim; Abay, Simon; Wilson, Chris; Wagner, Jakob B; Thelander, Claes; Delsing, Per; Samuelson, Lars

    2008-03-01

    We demonstrate radio frequency single-electron transistors fabricated from epitaxially grown InAs/InP heterostructure nanowires. Two sets of double-barrier wires with different barrier thicknesses were grown. The wires were suspended 15 nm above a metal gate electrode. Electrical measurements on a high-resistance nanowire showed regularly spaced Coulomb oscillations at a gate voltage from -0.5 to at least 1.8 V. The charge sensitivity was measured to 32 microe rms Hz(-1/2) at 1.5 K. A low-resistance single-electron transistor showed regularly spaced oscillations only in a small gate-voltage region just before carrier depletion. This device had a charge sensitivity of 2.5 microe rms Hz(-1/2). At low frequencies this device showed a typical 1/f noise behavior, with a level extrapolated to 300 microe rms Hz(-1/2) at 10 Hz.

  4. Use of a Flexible Inflatable Multi-Channel Applicator for Vaginal Brachytherapy in the Management of Gynecologic Cancer

    Directory of Open Access Journals (Sweden)

    Samuel M Shin

    2015-09-01

    Full Text Available Introduction: Evaluate use of novel multi-channel applicator (MC CapriTM to improve vaginal disease coverage achievable by single-channel applicator (SC and comparable to Syed plan simulation. Material and Methods: 28 plans were evaluated from 4 patients with primary or recurrent gynecologic cancer in the vagina. Each received whole pelvis radiation, followed by 3 weekly treatments using HDR brachytherapy with a 13-channel MC. Upper vagina was treated to 5 mm depth to 1500 cGy/3 fractions with a simultaneous integrated boost totaling 2100 cGy/3 fractions to tumor. Modeling of SC and Syed plans was performed using MC scans for each patient. Dosimetry for MC and SC plans was evaluated for PTV700 cGy coverage, maximum dose to 2cm3 to bladder, rectum as well as mucosal surface points. Dosimetry for Syed plans was calculated for PTV700 cGy coverage. Patients were followed for treatment response and toxicity.Results: Dosimetric analysis between MC and SC plans demonstrated increased tumor coverage (PTV700 cGy, with decreased rectal, bladder, and contralateral vaginal mucosa dose in favor of MC. These differences were significant (p<0.05. Comparison of MC and Syed plans demonstrated increased tumor coverage in favor of Syed plans which were not significant (p=0.71. Patients treated with MC had no cancer recurrence or ≥ grade 3 toxicity.Conclusion: Use of MC was efficacious and safe, providing superior coverage of tumor volumes ≤1cm depth compared to SC and comparable to Syed implant. MC avoids excess dose to surrounding organs compared to SC, and potentially less morbidity than Syed implants. For tumors extending ≤1cm depth, use of MC represents an alternative to an interstitial implant.

  5. Task Dependent Prefrontal Dysfunction in Persons with Asperger's Disorder Investigated with Multi-Channel Near-Infrared Spectroscopy

    Science.gov (United States)

    Iwanami, Akira; Okajima, Yuka; Ota, Haruhisa; Tani, Masayuki; Yamada, Takashi; Hashimoro, Ryuichiro; Kanai, Chieko; Watanabe, Hiromi; Yamasue, Hidenori; Kawakubo, Yuki; Kato, Nobumasa

    2011-01-01

    Dysfunction of the prefrontal cortex has been previously reported in individuals with Asperger's disorder. In the present study, we used multi-channel near-infrared spectroscopy (NIRS) to detect changes in the oxygenated hemoglobin concentration ([oxy-Hb]) during two verbal fluency tasks. The subjects were 20 individuals with Asperger's disorder…

  6. Determining electrical properties based on B1 fields measured in an MR scanner using a multi-channel transmit/receive coil: a general approach

    Science.gov (United States)

    Liu, Jiaen; Zhang, Xiaotong; Van de Moortele, Pierre-Francois; Schmitter, Sebastian; He, Bin

    2013-07-01

    Electrical properties tomography (EPT) is a recently developed noninvasive technology to image the electrical conductivity and permittivity of biological tissues at Larmor frequency in magnetic resonance scanners. The absolute phase of the complex radio-frequency magnetic field (B1) is necessary for electrical property calculation. However, due to the lack of practical methods to directly measure the absolute B1 phases, current EPT techniques have been achieved with B1 phase estimation based on certain assumptions on object anatomy, coil structure and/or electromagnetic wave behavior associated with the main magnetic field, limiting EPT from a larger variety of applications. In this study, using a multi-channel transmit/receive coil, the framework of a new general approach for EPT has been introduced, which is independent on the assumptions utilized in previous studies. Using a human head model with realistic geometry, a series of computer simulations at 7 T were conducted to evaluate the proposed method under different noise levels. Results showed that the proposed method can be used to reconstruct the conductivity and permittivity images with noticeable accuracy and stability. The feasibility of this approach was further evaluated in a phantom experiment at 7 T.

  7. Space charge effect measurements for a multi-channel ionization chamber used for synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Nasr, Amgad

    2012-07-18

    In vivo coronary angiography is one of the techniques used to investigate the heart diseases, by using catheter to inject a contrast medium of a given absorption coefficient into the heart vessels. Taking X-ray images produced by X-ray tube or synchrotron radiation for visualizing the blood in the coronary arteries. As the synchrotron radiation generated by the relativistic charged particle at the bending magnets, which emits high intensity photons in comparison with the X-ray tube. The intensity of the synchrotron radiation is varies with time. However for medical imaging it's necessary to measure the incoming intensity with the integrated time. The thesis work includes building a Multi-channel ionization chamber which can be filled with noble gases N{sub 2}, Ar and Xe with controlled inner pressure up to 30 bar. This affects the better absorption efficiency in measuring the high intensity synchrotron beam fluctuation. The detector is a part of the experimental setup used in the k-edge digital subtraction angiography project, which will be used for correcting the angiography images taken by another detector at the same time. The Multi-channel ionization chamber calibration characteristics are measured using 2 kW X-ray tube with molybdenum anode with characteristic energy of 17.44 keV. According to the fast drift velocity of the electrons relative to the positive ions, the electrons will be collected faster at the anode and will induce current signals, while the positive ions is still drifting towards the cathode. However the accumulation of the slow ions inside the detector disturbs the homogeneous applied electric field and leads to what is known a space charge effect. In this work the space charge effect is measured with very high synchrotron photons intensity from EDR beam line at BESSYII. The strong attenuation in the measured amplitude signal occurs when operating the chamber in the recombination region. A plateau is observed at the amplitude signal when

  8. Enabling Technology for the Exploration of the Arctic Ocean - Multi Channel Seismic Reflection data acquisition

    Science.gov (United States)

    Coakley, B.; Anderson, R.; Chayes, D. N.; Goemmer, S.; Oursler, M.

    2009-12-01

    Great advances in mapping the Arctic Ocean have recently been made through the relatively routine acquisition of multibeam data from icebreakers operating on various cruise. The USCGC Healy, the German icebreaker Polarstern, the Canadian icebreaker Amundsen and the Swedish icebreaker Oden all routinely collect multibeam data, even while in heavy ice pack. This increase in data has substantially improved our knowledge of the form of the Arctic Ocean seafloor. Unfortunately, it is not possible to routinely collect Multi Channel Seismic Reflection (MCS) data while underway in the ice pack. Our inability to simply collect these data restricts how we understand many of the features that segment the basin by depriving us of the historical information that can be obtained by imaging the stratigraphy. Without these data, scientific ocean drilling, the ultimate ground truth for Marine Geology, cannot be done. The technology and expertise to collect MCS must be adapted for the particular circumstances of the Arctic Ocean. While MCS data have been collected in the Arctic Ocean, the procedures have relied on icebreakers towing equipment. Since icebreakers follow the path of least resistance through the pack, data are acquired in locations that are not scientifically optimal and rarely in the relatively straight lines necessary for optimal processing. Towing in the ice pack is also difficult, inefficient and puts this equipment at substantial risk of crushing or loss. While icebreakers are one means to collect these data, it is time to conduct a systematic evaluation of the costs and benefits of different platforms for MCS data acquisition. This evaluation should enable collection of high-quality data set at selected locations to solve scientific problems. Substantial uncertainties exist about the relative capabilities, costs and limitations for acquisition of MCS data from various platforms in the Arctic Ocean. For example; - Is it possible to collect multi-channel seismic

  9. Digital coherent receiver for subcarrier multiplexed phase modulated radio-over-fibre signals

    DEFF Research Database (Denmark)

    Zibar, Darko; Larsen, Knud J.; Tafur Monroy, Idelfonso

    2009-01-01

    Digital coherent detection of multi-channel subcarrier multiplexed optically phase-modulated radio-over-fibre signals is experimentally demonstrated. Successful detection after transmission over a 40 km long fibre link of four or five 25 Mbaud BPSK/QPSK subcarrier channels in 5 GHz bandwidth...... is demonstrated using offline digital signal processing....

  10. Preparation of single-crystal TiC (111) by radio frequency magnetron sputtering at low temperature

    International Nuclear Information System (INIS)

    Qi, Q.; Zhang, W.Z.; Shi, L.Q.; Zhang, W.Y.; Zhang, W.; Zhang, B.

    2012-01-01

    Single-crystal films of TiC (111) have been synthesized at room temperature on Al 2 O 3 (0001) substrates by radio frequency magnetron sputtering using a compound Ti–C target. The substrate temperature and bias were varied to explore the influence of deposition parameters on the crystal structure. Both Al 2 O 3 (0001) and Si (100) substrates were used for epitaxial growth of TiC films. A series of characterizations of TiC films were carried out, including Rutherford backscattering spectroscopy, X-ray diffraction, Raman and X-ray photoelectron spectroscopy. Single-crystal films of TiC (111) on the Al 2 O 3 (0001) were demonstrated. - Highlights: ► Single-crystal films of TiC (111) have been synthesized by RF magnetron sputtering. ► Both temperature and bias affect greatly the TiC crystal structure. ► Al 2 O 3 substrate is much better than Si substrate for TiC epitaxial growth. ► TiC (111) epitaxial film can be grown on Al 2 O 3 (0001) at room temperature.

  11. Signal acquisition module design for multi-channel surface magnetic resonance sounding system.

    Science.gov (United States)

    Lin, Tingting; Chen, Wuqiang; Du, Wenyuan; Zhao, Jing

    2015-11-01

    To obtain a precise 2D/3D image of fissure or karst water, multi-channel magnetic resonance sounding (MRS) systems using edge-to-edge or overlapping receiving coils are needed. Thus, acquiring a nano-volt signal for a small amount of the aquifer and suppressing the mutual coupling between adjacent coils are two important issues for the design of the signal acquisition module in the system. In the present study, we propose to use a passive low pass filter, consisted of a resistance (R) and capacitance (C), to inhibit the mutual coupling effects of the coils. Four low-noise operational amplifiers LT1028, OPA124, AD745, and OP27 were compared with respect to achieving the lowest system noise. As a result, 3 pieces of LT1028 were chosen and connected in parallel to serve as preamplifier, with a sensitivity of 1.4 nV/√Hz at 2 kHz. Experimental results are presented for 2D MRS groundwater investigations conducted in the suburb of Changchun, China. The inversion result is consistent with the result of drilling log, suggesting that the signal acquisition module is well developed.

  12. Hyperbolic Positioning with Antenna Arrays and Multi-Channel Pseudolite for Indoor Localization

    Directory of Open Access Journals (Sweden)

    Kenjirou Fujii

    2015-09-01

    Full Text Available A hyperbolic positioning method with antenna arrays consisting of proximately-located antennas and a multi-channel pseudolite is proposed in order to overcome the problems of indoor positioning with conventional pseudolites (ground-based GPS transmitters. A two-dimensional positioning experiment using actual devices is conducted. The experimental result shows that the positioning accuracy varies centimeter- to meter-level according to the geometric relation between the pseudolite antennas and the receiver. It also shows that the bias error of the carrier-phase difference observables is more serious than their random error. Based on the size of the bias error of carrier-phase difference that is inverse-calculated from the experimental result, three-dimensional positioning performance is evaluated by computer simulation. In addition, in the three-dimensional positioning scenario, an initial value convergence analysis of the non-linear least squares is conducted. Its result shows that initial values that can converge to a right position exist at least under the proposed antenna setup. The simulated values and evaluation methods introduced in this work can be applied to various antenna setups; therefore, by using them, positioning performance can be predicted in advance of installing an actual system.

  13. Multi-Channel Amplifier-Discriminator for Highly Time-Resolved Detection

    CERN Document Server

    Despeisse, M; Lapington, J; Jarron, P

    2011-01-01

    A low-power multi-channel amplifier-discriminator was developed for application in highly time-resolved detection systems. The proposed circuit architecture, so-called Nino, is based on a time-over-threshold approach and shows a high potential for time-resolved readout of solid-state photo-detectors and of detectors based on vacuum technologies. The Irpics circuit was designed in a 250 nm CMOS technology, implementing 32 channels of a Nino version optimized to achieve high-time resolution on the output low-voltage differential signals (LVDS) while keeping a low power consumption of 10 mW per channel. Electrical characterizations of the circuit demonstrate a very low intrinsic time jitter on the output pulse leading edge, measured below 10 ps rms for each channel for high input signal charges (100 fC) and below 25 ps rms for low input signal charges (20-100 fC). The read-out architecture moreover permits to retrieve the input signal charge from the timing measurements, while a calibration procedure was develop...

  14. Multi-channel non-invasive fetal electrocardiography detection using wavelet decomposition

    Science.gov (United States)

    Almeida, Javier; Ruano, Josué; Corredor, Germán.; Romo-Bucheli, David; Navarro-Vargas, José Ricardo; Romero, Eduardo

    2017-11-01

    Non-invasive fetal electrocardiography (fECG) has attracted the medical community because of the importance of fetal monitoring. However, its implementation in clinical practice is challenging: the fetal signal has a low Signal- to-Noise-Ratio and several signal sources are present in the maternal abdominal electrocardiography (AECG). This paper presents a novel method to detect the fetal signal from a multi-channel maternal AECG. The method begins by applying filters and signal detrending the AECG signals. Afterwards, the maternal QRS complexes are identified and subtracted. The residual signals are used to detect the fetal QRS complex. Intervals of these signals are analyzed by using a wavelet decomposition. The resulting representation feds a previously trained Random Forest (RF) classifier that identifies signal intervals associated to fetal QRS complex. The method was evaluated on a public available dataset: the Physionet2013 challenge. A set of 50 maternal AECG records were used to train the RF classifier. The evaluation was carried out in signals intervals extracted from additional 25 maternal AECG. The proposed method yielded an 83:77% accuracy in the fetal QRS complex classification task.

  15. Titanium-based multi-channel, micro-electrode array for recording neural signals.

    Science.gov (United States)

    McCarthy, Patrick T; Madangopal, Rajtarun; Otto, Kevin J; Rao, Masaru P

    2009-01-01

    Micro-scale brain-machine interface (BMI) devices have provided an opportunity for direct probing of neural function and have also shown significant promise for restoring neurological functions lost to stroke, injury, or disease. However, the eventual clinical translation of such devices may be hampered by limitations associated with the materials commonly used for their fabrication, e.g. brittleness of silicon, insufficient rigidity of polymeric devices, and unproven chronic biocompatibility of both. Herein, we report, for the first time, the development of titanium-based "Michigan" type multi-channel, microelectrode arrays that seek to address these limitations. Titanium provides unique properties of immediate relevance to microelectrode arrays, such as high toughness, moderate modulus, and excellent biocompatibility, which may enhance structural reliability, safety, and chronic recording reliability. Realization of these devices is enabled by recently developed techniques which provide the opportunity for fabrication of high aspect ratio micromechanical structures in bulk titanium substrates. Details regarding the design, fabrication, and characterization of these devices for eventual use in rat auditory cortex and thalamus recordings are presented, as are preliminary results.

  16. A Cardiac Early Warning System with Multi Channel SCG and ECG Monitoring for Mobile Health

    Science.gov (United States)

    Sahoo, Prasan Kumar; Thakkar, Hiren Kumar; Lee, Ming-Yih

    2017-01-01

    Use of information and communication technology such as smart phone, smart watch, smart glass and portable health monitoring devices for healthcare services has made Mobile Health (mHealth) an emerging research area. Coronary Heart Disease (CHD) is considered as a leading cause of death world wide and an increasing number of people die prematurely due to CHD. Under such circumstances, there is a growing demand for a reliable cardiac monitoring system to catch the intermittent abnormalities and detect critical cardiac behaviors which lead to sudden death. Use of mobile devices to collect Electrocardiography (ECG), Seismocardiography (SCG) data and efficient analysis of those data can monitor a patient’s cardiac activities for early warning. This paper presents a novel cardiac data acquisition method and combined analysis of Electrocardiography (ECG) and multi channel Seismocardiography (SCG) data. An early warning system is implemented to monitor the cardiac activities of a person and accuracy assessment of the early warning system is conducted for the ECG data only. The assessment shows 88% accuracy and effectiveness of our proposed analysis, which implies the viability and applicability of the proposed early warning system. PMID:28353681

  17. Multi-channel high-speed CMOS image acquisition and pre-processing system

    Science.gov (United States)

    Sun, Chun-feng; Yuan, Feng; Ding, Zhen-liang

    2008-10-01

    A new multi-channel high-speed CMOS image acquisition and pre-processing system is designed to realize the image acquisition, data transmission, time sequential control and simple image processing by high-speed CMOS image sensor. The modular structure design, LVDS and ping-pong cache techniques used during the designed image data acquisition sub-system design ensure the real-time data acquisition and transmission. Furthermore, a new histogram equalization algorithm of adaptive threshold value based on the reassignment of redundant gray level is incorporated in the image preprocessing module of FPGA. The iterative method is used in the course of setting threshold value, and a redundant graylevel is redistributed rationally according to the proportional gray level interval. The over-enhancement of background is restrained and the feasibility of mergence of foreground details is reduced. The experimental certificates show that the system can be used to realize the image acquisition, transmission, memory and pre-processing to 590MPixels/s data size, and make for the design and realization of the subsequent system.

  18. Multi-channel integrated circuits for the detection and measurement of ionizing radiation

    International Nuclear Information System (INIS)

    Engel, G.L.; Duggireddi, N.; Vangapally, V.; Elson, J.M.; Sobotka, L.G.; Charity, R.J.

    2011-01-01

    The Integrated Circuits (IC) Design Research Laboratory at Southern Illinois University Edwardsville (SIUE) has collaborated with the Nuclear Reactions Group at Washington University (WU) to develop a family of multi-channel integrated circuits. To date, the collaboration has successfully produced two micro-chips. The first was an analog shaped and peak sensing chip with on-board constant-fraction discriminators and sparsified readout. This chip is known as Heavy-Ion Nuclear Physics-16 Channel (HINP16C). The second chip, christened PSD8C, was designed to logically complement (in terms of detector types) the HINP16C chip. Pulse Shape Discrimination-8 Channel (PSD8C), featuring three settable charge integration windows per channel, performs pulse shape discrimination (PSD). This paper summarizes the design, capabilities, and features of the HINP16C and PSD8C ICs. It proceeds to discuss the modifications, made to the ICs and their associated systems, which have attempted to improve ease of use, increase performance, and extend capabilities. The paper concludes with a brief discussion of what may be the next chip (employing a multi-sampling scheme) to be added to our CMOS ASIC 'tool box' for radiation detection instrumentation.

  19. A multi-channel time-to-digital converter chip for drift chamber readout

    International Nuclear Information System (INIS)

    Santos, D.M.; Chau, A.; DeBusshere, D.; Dow, S.; Flasck, J.; Levi, M.; Kirsten, F.; Su, E.

    1995-12-01

    A complete, multi-channel, timing and amplitude measurement IC for use in drift chamber applications is described. By targeting specific resolutions, i.e. 6-bits of resolution for both time and amplitude, area and power can be minimized while achieving the proper level of measurement accuracy. Time is digitized using one eight channel TDC comprised of a delay locked loop and eight sets of latches and encoders. Amplitude (for dE/dx) is digitized using a dual-range FADC for each channel. Eight bits of dynamic range with six bits of accuracy are achieved with the dual-range. The timing and amplitude information is multiplexed into one DRAM (Dynamic Random Access Memory) trigger latency buffer. Interesting events are then transferred into an SRAM (Static Random Access Memory) readout buffer before the latency time has expired. The design has been optimized to achieve the requisite resolution using the smallest area and lowest power. The circuit has been implemented in a 0.8μ triple metal CMOS process. The TDC sub-element has been measured to have better than 135 ps time resolution and 35 ps jitter. The DRAM has a measured cycle time of 80 MHz

  20. The Research of China's Civil Aviation Passenger Multi-Channel Service Technology Platform

    Science.gov (United States)

    Zhibing, Xue; Xinming, Wang

    IATA is promoting Simplifying the Business. The traditional passenger services and business process, such as ticketing, airport counters, had a great influence. The airlines have the passenger service and convenience as the next product development requirements. With civil aviation industry and their company's products construction, the authors propose a solution of passenger multi-channel service product platform. The solution is to streamline the business as the breakthrough point, around the convenience of passengers travel services to travelers as the center, using the current mainstream and the latest IT technology to establish passenger service product platform. The solution will promote DCS e-ticketing business development and service channel diversity. In this paper, the research results have been applied in the product platform construction of the authors' company. The practice shows that through traditional business with the latest IT technologies, traditional passenger services into the emerging service model, passenger service product platform has strong advantages and characteristics. Based on the platform, various types of service products is growing rapidly.

  1. Dimensionality Reduction on Multi-Dimensional Transfer Functions for Multi-Channel Volume Data Sets

    Science.gov (United States)

    Kim, Han Suk; Schulze, Jürgen P.; Cone, Angela C.; Sosinsky, Gina E.; Martone, Maryann E.

    2011-01-01

    The design of transfer functions for volume rendering is a non-trivial task. This is particularly true for multi-channel data sets, where multiple data values exist for each voxel, which requires multi-dimensional transfer functions. In this paper, we propose a new method for multi-dimensional transfer function design. Our new method provides a framework to combine multiple computational approaches and pushes the boundary of gradient-based multi-dimensional transfer functions to multiple channels, while keeping the dimensionality of transfer functions at a manageable level, i.e., a maximum of three dimensions, which can be displayed visually in a straightforward way. Our approach utilizes channel intensity, gradient, curvature and texture properties of each voxel. Applying recently developed nonlinear dimensionality reduction algorithms reduces the high-dimensional data of the domain. In this paper, we use Isomap and Locally Linear Embedding as well as a traditional algorithm, Principle Component Analysis. Our results show that these dimensionality reduction algorithms significantly improve the transfer function design process without compromising visualization accuracy. We demonstrate the effectiveness of our new dimensionality reduction algorithms with two volumetric confocal microscopy data sets. PMID:21841914

  2. Dimensionality Reduction on Multi-Dimensional Transfer Functions for Multi-Channel Volume Data Sets.

    Science.gov (United States)

    Kim, Han Suk; Schulze, Jürgen P; Cone, Angela C; Sosinsky, Gina E; Martone, Maryann E

    2010-09-21

    The design of transfer functions for volume rendering is a non-trivial task. This is particularly true for multi-channel data sets, where multiple data values exist for each voxel, which requires multi-dimensional transfer functions. In this paper, we propose a new method for multi-dimensional transfer function design. Our new method provides a framework to combine multiple computational approaches and pushes the boundary of gradient-based multi-dimensional transfer functions to multiple channels, while keeping the dimensionality of transfer functions at a manageable level, i.e., a maximum of three dimensions, which can be displayed visually in a straightforward way. Our approach utilizes channel intensity, gradient, curvature and texture properties of each voxel. Applying recently developed nonlinear dimensionality reduction algorithms reduces the high-dimensional data of the domain. In this paper, we use Isomap and Locally Linear Embedding as well as a traditional algorithm, Principle Component Analysis. Our results show that these dimensionality reduction algorithms significantly improve the transfer function design process without compromising visualization accuracy. We demonstrate the effectiveness of our new dimensionality reduction algorithms with two volumetric confocal microscopy data sets.

  3. Block sparsity-based joint compressed sensing recovery of multi-channel ECG signals.

    Science.gov (United States)

    Singh, Anurag; Dandapat, Samarendra

    2017-04-01

    In recent years, compressed sensing (CS) has emerged as an effective alternative to conventional wavelet based data compression techniques. This is due to its simple and energy-efficient data reduction procedure, which makes it suitable for resource-constrained wireless body area network (WBAN)-enabled electrocardiogram (ECG) telemonitoring applications. Both spatial and temporal correlations exist simultaneously in multi-channel ECG (MECG) signals. Exploitation of both types of correlations is very important in CS-based ECG telemonitoring systems for better performance. However, most of the existing CS-based works exploit either of the correlations, which results in a suboptimal performance. In this work, within a CS framework, the authors propose to exploit both types of correlations simultaneously using a sparse Bayesian learning-based approach. A spatiotemporal sparse model is employed for joint compression/reconstruction of MECG signals. Discrete wavelets transform domain block sparsity of MECG signals is exploited for simultaneous reconstruction of all the channels. Performance evaluations using Physikalisch-Technische Bundesanstalt MECG diagnostic database show a significant gain in the diagnostic reconstruction quality of the MECG signals compared with the state-of-the art techniques at reduced number of measurements. Low measurement requirement may lead to significant savings in the energy-cost of the existing CS-based WBAN systems.

  4. A novel human--machine interface based on recognition of multi-channel facial bioelectric signals.

    Science.gov (United States)

    Mohammad Rezazadeh, Iman; Firoozabadi, S Mohammad; Hu, Huosheng; Hashemi Golpayegani, S Mohammad Reza

    2011-12-01

    This paper presents a novel human-machine interface for disabled people to interact with assistive systems for a better quality of life. It is based on multi-channel forehead bioelectric signals acquired by placing three pairs of electrodes (physical channels) on the Frontalis and Temporalis facial muscles. The acquired signals are passed through a parallel filter bank to explore three different sub-bands related to facial electromyogram, electrooculogram and electroencephalogram. The root mean square features of the bioelectric signals analyzed within non-overlapping 256 ms windows were extracted. The subtractive fuzzy c-means clustering method (SFCM) was applied to segment the feature space and generate initial fuzzy based Takagi-Sugeno rules. Then, an adaptive neuro-fuzzy inference system is exploited to tune up the premises and consequence parameters of the extracted SFCMs rules. The average classifier discriminating ratio for eight different facial gestures (smiling, frowning, pulling up left/right lips corner, eye movement to left/right/up/down) is between 93.04% and 96.99% according to different combinations and fusions of logical features. Experimental results show that the proposed interface has a high degree of accuracy and robustness for discrimination of 8 fundamental facial gestures. Some potential and further capabilities of our approach in human-machine interfaces are also discussed.

  5. A multi-channel model for an α plus {sup 6}He nucleus cluster

    Energy Technology Data Exchange (ETDEWEB)

    Amos, K.; Karataglidis, S. [University of Melbourne, School of Physics, Victoria (Australia); University of Johannesburg, Department of Physics, Auckland Park (South Africa); Canton, L. [Istituto Nazionale di Fisica Nucleare, Padova (Italy); Fraser, P.R. [Curtin University, Department of Physics, Astronomy and Medical Radiation Sciences, Perth (Australia); Svenne, J.P. [Department of Physics and Astronomy, University of Manitoba, and Winnipeg Institute for Theoretical Physics, Winnipeg, MB (Canada); Van der Knijff, D. [University of Melbourne, School of Physics, Victoria (Australia)

    2017-04-15

    A multi-channel algebraic scattering (MCAS) method has been used to solve coupled sets of Lippmann-Schwinger equations for the α + {sup 6}He cluster system, so finding a model spectrum for {sup 10}Be to more than 10MeV excitation. Three states of {sup 6}He were included and the resonance character of the two excited states taken into account in finding solutions. A model Hamiltonian has been found that gives very good agreement with the known bound states and with some low-lying resonances of {sup 10}Be. More resonance states are predicted than those which have been observed as yet. The method also yields S-matrices which we have used to evaluate low-energy {sup 6}He-α scattering cross sections. Reasonable reproduction of low-energy differential cross sections and of energy variation of cross sections measured at fixed scattering angles have been found. Enlarging the channel space by including two higher energy states of {sup 6}He, assuming values for their spin-parities, leads to an enlarged spectrum for {sup 10}Be in which the number and distribution of resonances show similarity to the known spectrum. (orig.)

  6. The development of a digital multi-channel pulse height analysis

    International Nuclear Information System (INIS)

    Huang Shanshan; Sang Ziru; Liang Futian; Chen Lian; Liang Hao; Jin Ge

    2012-01-01

    A kind of digital multi-channel analyzer which was developed for Nuclear and Particle Experiment of Undergraduate Student in university was introduced. The input signal is digitalized with a high speed ADC, and feed to a FPGA for seeking peak, recording, spectrometer processing and displaying automatically. The principle of digital searching peck was given in the paper. In order to improve the capability of anti-noise, a dual digital thresholds and dual buffer memories was designed. Aiming at the influence of nonlinear of ADC to the system, a revised algorithm was designed to ensure the channel width uniformity. Since the huge sampling and storaging data of MCA, a method of parallel work of double memory was used, just separated empty transmit data and stored count, reduced the dead time and data overflowing. The host computer can set up and monitor MCA real-time, read and write data from MCA by an USB interface. Contrasts commercial MCA, the MCA has a good result in function and price. (authors)

  7. Prefrontal activation during two Japanese Stroop tasks revealed with multi-channel near-infrared spectroscopy.

    Science.gov (United States)

    Watanabe, Yukina; Sumitani, Satsuki; Hosokawa, Mai; Ohmori, Tetsuro

    2015-01-01

    The Stroop task is sometimes used in psychiatric research to elicit prefrontal activity, which presumably reflects cognitive functioning. Although there are two Stroop tasks (Kana script and Kanji script) in Japan, it is unclear whether these tasks elicit the same hemoglobin changes. Moreover, it is unclear whether psychological conditions or characteristics influence hemoglobin changes in the Japanese Stroop task. The aim of this study was to clarify whether hemoglobin changes elicited by the two Japanese Stroop tasks accurately reflected cognitive functioning. Hemoglobin changes were measured with multi-channel near-infrared spectroscopy (NIRS) in 100 healthy Japanese participants performing two Japanese Stroop tasks. The Beck-Depression Inventory (BDI), State-Trait-Anxiety Inventory (STAI), and Maudsley Obsessive Compulsive Inventory (MOCI) were administered to participants to identify psychological conditions or personality characteristics. Compared with the Kanji task, the Kana task produced a greater Stroop effect and a larger increase in oxyhemoglobin (oxy-Hb) concentration. Moreover there were no significant correlations between oxy-Hb concentration and BDI, STAI-trait, STAI-state, or MOCI scores. Therefore we found that a participant's psychological conditions or characteristics did not influence the hemodynamic changes during either task. These data suggest the Kana Stroop task is more useful than the Kanji Stroop task for NIRS studies in psychiatric research.

  8. A compact multi-channel fluorescence sensor with ambient light suppression

    Science.gov (United States)

    Egly, Dominik; Geörg, Daniel; Rädle, Matthias; Beuermann, Thomas

    2012-03-01

    A multi-channel fluorescence sensor has been developed for process monitoring and fluorescence diagnostics. It comprises a fiber-optic set-up with an immersion probe and an intensity-modulated high power ultraviolet light-emitting diode as a light source for fluorescence excitation. By applying an electronic lock-in procedure, fluorescence signals are selectively detectable at ambient light levels of 1000 000 times higher intensity. The sensor was designed to be compact, low cost and easily adaptable to a wide field of application. The set-up was used to simultaneously monitor three important metabolic fluorophores: NAD(P)H, flavins and porphyrins during the cultivation of a baker's yeast. Moreover, the accumulation and degradation kinetics of protoporphyrin IX induced by 5-aminolevulinic acid on the skin could be recorded by the sensor. The detection limit for protoporphyrin IX was determined to be 4 × 10-11 mol L-1. The linear signal amplification of the sensor and time courses of fluorescence signals monitored during yeast fermentations were validated using a commercial CCD spectrometer. The robust and flexible set-up of the fiber-optic measurement system promises easy implementation of this non-invasive analytical tool to fluorescence monitoring and diagnostics in R&D and production.

  9. Exploring Multi-Channel Shopping Behavior Towards It & C Products, Based on Business Students Opinions

    Directory of Open Access Journals (Sweden)

    Cristinel Vasiliu

    2016-02-01

    Full Text Available Young people have rapidly adopted the practice of using a variety of channels through which to shop, especially for products that require thorough information on features and price. IT & C products fall into this category, and buyers using multiple channels benefit from the advantages of information from online stores and reduced risks associated with the acquisition from traditional stores. The aim of this article is to identify young people preference for buying IT & C products from companies that distribute them across multiple channels. In this regard, an exploratory research was conducted on a sample of 340 students. The main results showed the high frequency use of Internet as a means of searching the information needed for purchasing IT & C products, the low share of exclusively online purchase, the fact that they are being perceived by students as both a need and a desire, and the weak expression of views about products purchased in the virtual environment. Price and quality are the main criteria in choosing them. Originality of this article is determined by identifying students’ preference for firms practicing multi-channel distribution strategy for IT & C products. Basically, people that we investigated gather online information about these products, from companies’ sites, but they mainly buy them in traditional stores.

  10. Implementation of a galvanically isolated low-noise power supply board for multi-channel headstage preamplifiers.

    Science.gov (United States)

    Tóth, Attila; Máthé, Kálmán; Petykó, Zoltán; Szabó, Imre; Czurkó, András

    2008-06-15

    Custom made multi-channel headstage preamplifiers are traditionally powered by battery. By the use of an isolated unregulated DC/DC converter integrated circuit (DCP010512B from Texas Instruments Inc., TX, USA), here we describe the implementation of a galvanically isolated low-noise power supply board for multi-channel headstage preamplifiers. The implemented galvanically isolated power supply board provides the same quality noise free recording as the battery power supply. The non-isolated part of the power supply board is powered by standard 230 V AC/6 V DC wall mount adapter or USB cable. The described galvanically isolated power supply board can replace the batteries in preamplifier power supplies without any deterioration of the quality of recordings.

  11. Experimental researches and comparison on aerodynamic parameters and cleaning efficiency of multi-level multi-channel cyclone

    Directory of Open Access Journals (Sweden)

    Aleksandras Chlebnikovas

    2015-10-01

    Full Text Available Multi-level multi-channel cyclone – the lately designed air cleaning device that can remove ultra-fine 20 μm particulatematter (PM from dusted air and reach over 95% of the overall cleaning efficiency. Multi-channel cyclone technology is based on centrifugal forces and has the resulting additional filtering process operation. Multi-level structure of cyclone allows to achieve higher air flow cleaning capacity at the same dimensions of the device, thus saving installation space required for the job, production and operating costs. Studies have examined the air flow parameters change in one–, two– and three–levels multichannel cyclone. These constructions differ according to the productivity of cleaned air under the constant peripheral and transitional (50/50 case air flow relations. Accordance with the results of air flow dynamics – velocity distribution of multi-channel cyclone, aerodynamic resistance and efficiency can be judged on the flow turbulence, the flow channel cross-section and select the most appropriate application. Cleaning efficiency studies were carried out using fine granite and wood ashes PM. The maximum cleaning efficiency was 93.3%, at an average of 4.5 g/m3, the aerodynamic resistance was equal to 1525 Pa.

  12. Compensation of multi-channel mismatches in high-speed high-resolution photonic analog-to-digital converter.

    Science.gov (United States)

    Yang, Guang; Zou, Weiwen; Yu, Lei; Wu, Kan; Chen, Jianping

    2016-10-17

    We demonstrate a method to compensate multi-channel mismatches that intrinsically exist in a photonic analog-to-digital converter (ADC) system. This system, nominated time-wavelength interleaved photonic ADC (TWI-PADC), is time-interleaved via wavelength demultiplexing/multiplexing before photonic sampling, wavelength demultiplexing channelization, and electronic quantization. Mismatches among multiple channels are estimated in frequency domain and hardware adjustment are used to approach the device-limited accuracy. A multi-channel mismatch compensation algorithm, inspired from the time-interleaved electronic ADC, is developed to effectively improve the performance of TWI-PADC. In the experiment, we configure out a 4-channel TWI-PADC system with 40 GS/s sampling rate based on a 10-GHz actively mode-locked fiber laser. After multi-channel mismatch compensation, the effective number of bit (ENOB) of the 40-GS/s TWI-PADC system is enhanced from ~6 bits to >8.5 bits when the RF frequency is within 0.1-3.1 GHz and from ~6 bits to >7.5 bits within 3.1-12.1 GHz. The enhanced performance of the TWI-PADC system approaches the limitation determined by the timing jitter and noise.

  13. Intsy: a low-cost, open-source, wireless multi-channel bioamplifier system.

    Science.gov (United States)

    Erickson, Jonathan C; Hayes, James A; Bustamante, Mauricio; Joshi, Rajwol; Rwagaju, Alfred; Paskaranandavadivel, Niranchan; Angeli, Timothy R

    2018-02-06

    Multi-channel electrical recordings of physiologically generated signals are common to a wide range of biomedical fields. The aim of this work was to develop, validate, and demonstrate the practical utility of a high-quality, low-cost 32/64-channel bioamplifier system with real-time wireless data streaming capability. The new "Intsy" system integrates 3 main off-the-shelf hardware components: 1) Intan RHD2132 bioamplifier; 2) Teensy 3.2 microcontroller; and 3) RN-42 Bluetooth 2.1 module with a custom LabView interface for real-time data streaming and visualization. Practical utility was validated by measuring serosal gastric slow waves and surface EMG on the forearm with various contraction force levels. Quantitative comparisons were made to a gold-standard commercial system (Biosemi ActiveTwo). Intsy signal quality was quantitatively comparable to that of the ActiveTwo. Recorded slow wave signals had high SNR (24 ± 2.7 dB) and wavefront propagation was accurately mapped. Surface EMG spike bursts were characterized by high SNR (≥10 dB) and activation timing was readily identified. Stable data streaming rates achieved were 3.5 kS/s for wireless and 64 kS/s for USB-wired transmission. Intsy has the highest channel count of any existing open-source, wireless-enabled module. The flexibility, portability and low cost ($1300 for the 32-channel version, or $2500 for 64 channels) of this new hardware module reduce the entry barrier for a range of electrophysiological experiments, as are typical in the gastrointestinal (EGG), cardiac (ECG), neural (EEG), and neuromuscular (EMG) domains. © 2018 Institute of Physics and Engineering in Medicine.

  14. Optical single sideband modulation radio over fiber system by using a fiber-Bragg-grating-based acousto-optic filter

    Science.gov (United States)

    Gao, Song; Pei, Li; Li, Zhuoxuan; Liu, Chao; Wang, Yiqun; Weng, Sijun

    2013-03-01

    An optical single sideband (OSSB) modulation radio over a fiber system, by using an acousto-optic filter (AOF), is proposed and demonstrated. In the AOF, a uniform fiber Bragg grating is etched and modulated by an axially propagating acoustic wave. Due to the acousto-optic superlattice modulation, two secondary reflection peaks, centered on the primary reflection peak, are generated. In the scheme, an optical double-sideband signal passes though the AOF to realize OSSB modulation. Because the reflect depth of the primary peak is much deeper than those of the secondary peaks, the carrier experiences higher attenuation than the upper sideband, which means the carrier-to-sideband ratio (CSR) can be optimized at the same time. We demonstrate this scheme via simulations, and successfully reduce the CSR from 9.73 to 2.9 dB. As a result, the receiving sensitivity improved from -23.43 to -31.18 dBm at BER of 10-9 with 30 km long SMF.

  15. Take time to make time : What to consider when managing multi-channel sales systems with the objective to increase sales efficiency

    OpenAIRE

    ALM, RAGNAR; KYRÖNLAHTI, RUDY

    2016-01-01

    Traditional sales systems have been disrupted by technological developments. In order to  adapt, companies are changing the way they interact with their customers in business-to-business markets. In the last three decades, multi-channel strategies have spurred the proliferation of different sales channels and new ways of managing sales systems. The purpose of this research was to investigate what should be considered when managing multi-channel sales systems with the objective of increasing s...

  16. Multi-channel programmable power supply with temperature compensation for silicon sensors.

    Science.gov (United States)

    Shukla, R A; Achanta, V G; Dugad, S R; Freeman, J; Garde, C S; Gupta, S K; Khandekar, P D; Kurup, A M; Lokhandwala, S S; Los, S; Prabhu, S S; Rakshe, P S

    2016-01-01

    Silicon Photo-Multipliers (SiPMs) are increasingly becoming popular for discrete photon counting applications due to the wealth of advantages they offer over conventional photo-detectors such as photo-multiplier tubes and hybrid photo-diodes. SiPMs are used in variety of applications ranging from high energy physics and nuclear physics experiments to medical diagnostics. The gain of a SiPM is directly proportional to the difference between applied and breakdown voltage of the device. However, the breakdown voltage depends critically on the ambient temperature and has a large temperature co-efficient in the range of 40-60 mV/°C resulting in a typical gain variation of 3%-5%/°C [Dinu et al., in IEEE Nuclear Science Symposium, Medical Imaging Conference and 17th Room Temperature Semiconductor Detector Workshop (IEEE, 2010), p. 215]. We plan to use the SiPM as a replacement for PMT in the cosmic ray experiment (GRAPES-3) at Ooty [Gupta et al., Nucl. Instrum. Methods Phys. Res., Sect. A 540, 311 (2005)]. There the SiPMs will be operated in an outdoor environment subjected to temperature variation of about 15 °C over a day. A gain variation of more than 50% was observed for such large variations in the temperature. To stabilize the gain of the SiPM under such operating conditions, a low-cost, multi-channel programmable power supply (0-90 V) was designed that simultaneously provides the bias voltage to 16 SiPMs. The programmable power supply (PPS) was designed to automatically adjust the operating voltage for each channel with a built-in closed loop temperature feedback mechanism. The PPS provides bias voltage with a precision of 6 mV and measures the load current with a precision of 1 nA. Using this PPS, a gain stability of 0.5% for SiPM (Hamamatsu, S10931-050P) has been demonstrated over a wide temperature range of 15 °C. The design methodology of the PPS system, its validation, and the results of the tests carried out on the SiPM is presented in this

  17. Nonlocal atlas-guided multi-channel forest learning for human brain labeling.

    Science.gov (United States)

    Ma, Guangkai; Gao, Yaozong; Wu, Guorong; Wu, Ligang; Shen, Dinggang

    2016-02-01

    It is important for many quantitative brain studies to label meaningful anatomical regions in MR brain images. However, due to high complexity of brain structures and ambiguous boundaries between different anatomical regions, the anatomical labeling of MR brain images is still quite a challenging task. In many existing label fusion methods, appearance information is widely used. However, since local anatomy in the human brain is often complex, the appearance information alone is limited in characterizing each image point, especially for identifying the same anatomical structure across different subjects. Recent progress in computer vision suggests that the context features can be very useful in identifying an object from a complex scene. In light of this, the authors propose a novel learning-based label fusion method by using both low-level appearance features (computed from the target image) and high-level context features (computed from warped atlases or tentative labeling maps of the target image). In particular, the authors employ a multi-channel random forest to learn the nonlinear relationship between these hybrid features and target labels (i.e., corresponding to certain anatomical structures). Specifically, at each of the iterations, the random forest will output tentative labeling maps of the target image, from which the authors compute spatial label context features and then use in combination with original appearance features of the target image to refine the labeling. Moreover, to accommodate the high inter-subject variations, the authors further extend their learning-based label fusion to a multi-atlas scenario, i.e., they train a random forest for each atlas and then obtain the final labeling result according to the consensus of results from all atlases. The authors have comprehensively evaluated their method on both public LONI_LBPA40 and IXI datasets. To quantitatively evaluate the labeling accuracy, the authors use the dice similarity coefficient

  18. Nonlocal atlas-guided multi-channel forest learning for human brain labeling

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Guangkai [Space Control and Inertial Technology Research Center, Harbin Institute of Technology, Harbin 150001, China and Department of Radiology and BRIC, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599 (United States); Gao, Yaozong; Wu, Guorong [Department of Computer Science, Department of Radiology, and BRIC, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599 (United States); Wu, Ligang [Space Control and Inertial Technology Research Center, Harbin Institute of Technology, Harbin 150001 (China); Shen, Dinggang, E-mail: dgshen@med.unc.edu [Department of Radiology and BRIC, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599 and Department of Brain and Cognitive Engineering, Korea University, Seoul 02841 (Korea, Republic of)

    2016-02-15

    Purpose: It is important for many quantitative brain studies to label meaningful anatomical regions in MR brain images. However, due to high complexity of brain structures and ambiguous boundaries between different anatomical regions, the anatomical labeling of MR brain images is still quite a challenging task. In many existing label fusion methods, appearance information is widely used. However, since local anatomy in the human brain is often complex, the appearance information alone is limited in characterizing each image point, especially for identifying the same anatomical structure across different subjects. Recent progress in computer vision suggests that the context features can be very useful in identifying an object from a complex scene. In light of this, the authors propose a novel learning-based label fusion method by using both low-level appearance features (computed from the target image) and high-level context features (computed from warped atlases or tentative labeling maps of the target image). Methods: In particular, the authors employ a multi-channel random forest to learn the nonlinear relationship between these hybrid features and target labels (i.e., corresponding to certain anatomical structures). Specifically, at each of the iterations, the random forest will output tentative labeling maps of the target image, from which the authors compute spatial label context features and then use in combination with original appearance features of the target image to refine the labeling. Moreover, to accommodate the high inter-subject variations, the authors further extend their learning-based label fusion to a multi-atlas scenario, i.e., they train a random forest for each atlas and then obtain the final labeling result according to the consensus of results from all atlases. Results: The authors have comprehensively evaluated their method on both public LONI-LBPA40 and IXI datasets. To quantitatively evaluate the labeling accuracy, the authors use the

  19. Multi-channel programmable power supply with temperature compensation for silicon sensors

    Science.gov (United States)

    Shukla, R. A.; Achanta, V. G.; Dugad, S. R.; Freeman, J.; Garde, C. S.; Gupta, S. K.; Khandekar, P. D.; Kurup, A. M.; Lokhandwala, S. S.; Los, S.; Prabhu, S. S.; Rakshe, P. S.

    2016-01-01

    Silicon Photo-Multipliers (SiPMs) are increasingly becoming popular for discrete photon counting applications due to the wealth of advantages they offer over conventional photo-detectors such as photo-multiplier tubes and hybrid photo-diodes. SiPMs are used in variety of applications ranging from high energy physics and nuclear physics experiments to medical diagnostics. The gain of a SiPM is directly proportional to the difference between applied and breakdown voltage of the device. However, the breakdown voltage depends critically on the ambient temperature and has a large temperature co-efficient in the range of 40-60 mV/°C resulting in a typical gain variation of 3%-5%/°C [Dinu et al., in IEEE Nuclear Science Symposium, Medical Imaging Conference and 17th Room Temperature Semiconductor Detector Workshop (IEEE, 2010), p. 215]. We plan to use the SiPM as a replacement for PMT in the cosmic ray experiment (GRAPES-3) at Ooty [Gupta et al., Nucl. Instrum. Methods Phys. Res., Sect. A 540, 311 (2005)]. There the SiPMs will be operated in an outdoor environment subjected to temperature variation of about 15 °C over a day. A gain variation of more than 50% was observed for such large variations in the temperature. To stabilize the gain of the SiPM under such operating conditions, a low-cost, multi-channel programmable power supply (0-90 V) was designed that simultaneously provides the bias voltage to 16 SiPMs. The programmable power supply (PPS) was designed to automatically adjust the operating voltage for each channel with a built-in closed loop temperature feedback mechanism. The PPS provides bias voltage with a precision of 6 mV and measures the load current with a precision of 1 nA. Using this PPS, a gain stability of 0.5% for SiPM (Hamamatsu, S10931-050P) has been demonstrated over a wide temperature range of 15 °C. The design methodology of the PPS system, its validation, and the results of the tests carried out on the SiPM is presented in this article. The

  20. Nonlocal atlas-guided multi-channel forest learning for human brain labeling

    International Nuclear Information System (INIS)

    Ma, Guangkai; Gao, Yaozong; Wu, Guorong; Wu, Ligang; Shen, Dinggang

    2016-01-01

    Purpose: It is important for many quantitative brain studies to label meaningful anatomical regions in MR brain images. However, due to high complexity of brain structures and ambiguous boundaries between different anatomical regions, the anatomical labeling of MR brain images is still quite a challenging task. In many existing label fusion methods, appearance information is widely used. However, since local anatomy in the human brain is often complex, the appearance information alone is limited in characterizing each image point, especially for identifying the same anatomical structure across different subjects. Recent progress in computer vision suggests that the context features can be very useful in identifying an object from a complex scene. In light of this, the authors propose a novel learning-based label fusion method by using both low-level appearance features (computed from the target image) and high-level context features (computed from warped atlases or tentative labeling maps of the target image). Methods: In particular, the authors employ a multi-channel random forest to learn the nonlinear relationship between these hybrid features and target labels (i.e., corresponding to certain anatomical structures). Specifically, at each of the iterations, the random forest will output tentative labeling maps of the target image, from which the authors compute spatial label context features and then use in combination with original appearance features of the target image to refine the labeling. Moreover, to accommodate the high inter-subject variations, the authors further extend their learning-based label fusion to a multi-atlas scenario, i.e., they train a random forest for each atlas and then obtain the final labeling result according to the consensus of results from all atlases. Results: The authors have comprehensively evaluated their method on both public LONI-LBPA40 and IXI datasets. To quantitatively evaluate the labeling accuracy, the authors use the

  1. Multi-channel counter-current chromatography for high-throughput fractionation of natural products for drug discovery.

    Science.gov (United States)

    Wu, Shihua; Yang, Lu; Gao, Yuan; Liu, Xiaoyue; Liu, Feiyan

    2008-02-08

    A multi-channel counter-current chromatography (CCC) method has been designed and fabricated for the high-throughput fractionation of natural products without complications sometimes encountered with other conventional chromatographic systems, such as irreversible adsorptive constituent losses and deactivation, tailing of solute peaks and contamination. It has multiple independent CCC channels and each channel connects independent separation column(s) by parallel flow tubes, and thus the multi-channel CCC apparatus can achieve simultaneously two or more independent chromatographic processes. Furthermore, a high-throughput CCC fractionation method for natural products has been developed by a combination of a new three-channel CCC apparatus and conventional parallel chromatographic devices including pumps, sample injectors, effluent detectors and collectors, and its performance has been displayed on the fractionation of ethyl acetate extracts of three natural materials Solidago canadensis, Suillus placidus, and Trichosanthes kirilowii, which are found to be potent cytotoxic to tumor cell lines in the course of screening the antitumor candidates. By combination of biological screening programs and preparative high-performance liquid chromatography (HPLC) purification, 22.8 mg 6 beta-angeloyloxykolavenic acid and 29.4 mg 6 beta-tigloyloxykolavenic acid for S. canadensis, 25.3mg suillin for S. placidus, and 6.8 mg 23,24-dihydrocucurbitacin B for T. Kirilowii as their major cytotoxic principles were isolated from each 1000 mg crude ethyl acetate extract. Their chemical structures were characterized by electrospray ionization mass spectrometry, one- and two-dimensional nuclear magnetic resonance. The overall results indicate the multi-channel CCC is very useful for high-throughput fractionation of natural products for drug discovery in spite of the solvent balancing requirement and the lower resolution of the shorter CCC columns.

  2. Multi-channel EEG-based sleep stage classification with joint collaborative representation and multiple kernel learning.

    Science.gov (United States)

    Shi, Jun; Liu, Xiao; Li, Yan; Zhang, Qi; Li, Yingjie; Ying, Shihui

    2015-10-30

    Electroencephalography (EEG) based sleep staging is commonly used in clinical routine. Feature extraction and representation plays a crucial role in EEG-based automatic classification of sleep stages. Sparse representation (SR) is a state-of-the-art unsupervised feature learning method suitable for EEG feature representation. Collaborative representation (CR) is an effective data coding method used as a classifier. Here we use CR as a data representation method to learn features from the EEG signal. A joint collaboration model is established to develop a multi-view learning algorithm, and generate joint CR (JCR) codes to fuse and represent multi-channel EEG signals. A two-stage multi-view learning-based sleep staging framework is then constructed, in which JCR and joint sparse representation (JSR) algorithms first fuse and learning the feature representation from multi-channel EEG signals, respectively. Multi-view JCR and JSR features are then integrated and sleep stages recognized by a multiple kernel extreme learning machine (MK-ELM) algorithm with grid search. The proposed two-stage multi-view learning algorithm achieves superior performance for sleep staging. With a K-means clustering based dictionary, the mean classification accuracy, sensitivity and specificity are 81.10 ± 0.15%, 71.42 ± 0.66% and 94.57 ± 0.07%, respectively; while with the dictionary learned using the submodular optimization method, they are 80.29 ± 0.22%, 71.26 ± 0.78% and 94.38 ± 0.10%, respectively. The two-stage multi-view learning based sleep staging framework outperforms all other classification methods compared in this work, while JCR is superior to JSR. The proposed multi-view learning framework has the potential for sleep staging based on multi-channel or multi-modality polysomnography signals. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Portable e-Tongue based on Multi-channel LAPS Array with PVC Membrane for Rapid Environment Detection

    Science.gov (United States)

    Ha, D.; Yu, H.; Hu, N.; Wu, C. X.; Zhou, J.; Kirsanov, Dmitry; Legin, Andrey; Wang, P.

    2011-09-01

    A new kind of portable e-Tongue based on multi-channel LAPS array with PVC membrane has been designed for the rapid detection of environment situation, especially the seawater. It has the great advantages of depositing membranes which are offered by Chemistry Department, Saint-Petersburg State University on the sensors artificially with convenience and efficiency. To detect various heavy metal ions (Pb2+, Cd2+, Zn2+) simultaneously, respective Polyvinyl Chloride (PVC) membrane could be prepared on the surface of the silicon-based sensor in different channel.

  4. A multi-channel 24.4 ps bin size Time-to-Digital Converter for HEP applications

    CERN Document Server

    Mester, C; Morira, P

    2008-01-01

    A multi-channel time-tagging Time-to-Digital Converter (TDC) ASIC with a resolution of 24.4 ps (bin size) has been implemented and fabricated in a 130 nm CMOS technology. An on-chip PLL is used to generate an internal timing reference from an external 40 MHz clock source. The circuit is based on a 32 element Delay Locked Loop (DLL) which performs the time interpolation. The 32 channel architecture of the TDC is suitable for both triggered and non-triggered applications. The prototype contains test structures such as a substrate noise generator. The paper describes the circuit architecture and its principles of operation.

  5. Distributed capillary adiabatic tissue homogeneity model in parametric multi-channel blind AIF estimation using DCE-MRI

    Czech Academy of Sciences Publication Activity Database

    Kratochvíla, Jiří; Jiřík, Radovan; Bartoš, M.; Standara, M.; Starčuk jr., Zenon; Taxt, T.

    2016-01-01

    Roč. 75, č. 3 (2016), s. 1355-1365 ISSN 0740-3194 R&D Projects: GA ČR GAP102/12/2380; GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : dynamic contrast-enhanced magnetic resonance imaging * multi-channel blind deconvolution * arterial input function * impulse residue function * renal cell carcinoma Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 3.924, year: 2016

  6. ON SCALAR MESONS FROM THE COMBINED ANALYSIS OF MULTI-CHANNEL pi pi SCATTERING AND J/psi DECAYS

    Czech Academy of Sciences Publication Activity Database

    Surovtsev, Yu .S.; Bydžovský, Petr; Gutsche, T.; Lyubovitskij, V. E.

    2011-01-01

    Roč. 26, 3-4 (2011), s. 610-612 ISSN 0217-751X. [11th International Workshop on Meson Production , Properties and Interaction. Krakow, 10.06.2010-15.06.2010] R&D Projects: GA ČR GA202/08/0984 Institutional research plan: CEZ:AV0Z10480505 Keywords : Multi-channel pion-pion scattering * scalar-isoscalar resonances * multichannel analysis Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.053, year: 2011

  7. Multi-channel Wiener Filter for Speech Dereverberation in Hearing Aids - Sensitivity to DoA Errors

    DEFF Research Database (Denmark)

    Kuklasinski, Adam; Doclo, Simon; Jensen, Søren Holdt

    2016-01-01

    In this paper we study the robustness of a recently proposed Multi-channel Wiener Filter-based speech dereverberation algorithm to errors in the assumed direction of arrival (DoA) of the target speech. Different subsets of microphones of a pair of behind-the-ear hearing aids are used to construct......, in conditions where the assumed DoA is increasingly incorrect, the performance of the binaural configurations is shown to deteriorate more quickly than that of the monaural configurations. In effect, for large DoA errors it is the simpler, monaural configurations that perform better....

  8. Extraction of auditory features and elicitation of attributes for the assessment of multi-channel reproduced sound

    DEFF Research Database (Denmark)

    Choisel, Sylvain; Wickelmaier, Florian

    2005-01-01

    The identification of relevant auditory attributes is pivotal in sound quality evaluation. Two fundamentally different psychometric methods were employed to uncover perceptually relevant auditory features of multi-channel reproduced sound. In the first method, called Repertory Grid Technique (RGT......), subjects were asked to directly assign verbal labels to the features when encountering them, and to subsequently rate the sounds on the scales thus obtained. The second method requires the subjects to consistently identify the perceptually relevant features before assigning them a verbal label. Under...... sufficient consistency, a lattice representation -- as frequently used in Formal Concept Analysis (FCA) -- can be derived to depict the structure of auditory features....

  9. Mapping of calf muscle oxygenation and haemoglobin content during dynamic plantar flexion exercise by multi-channel time-resolved near-infrared spectroscopy

    Science.gov (United States)

    Torricelli, Alessandro; Quaresima, Valentina; Pifferi, Antonio; Biscotti, Giovanni; Spinelli, Lorenzo; Taroni, Paola; Ferrari, Marco; Cubeddu, Rinaldo

    2004-03-01

    A compact and fast multi-channel time-resolved near-infrared spectroscopy system for tissue oximetry was developed. It employs semiconductor laser and fibre optics for delivery of optical signals. Photons are collected by eight 1 mm fibres and detected by a multianode photomultiplier. A time-correlated single photon counting board is used for the parallel acquisition of time-resolved reflectance curves. Estimate of the reduced scattering coefficient is achieved by fitting with a standard model of diffusion theory, while the modified Lambert-Beer law is used to assess the absorption coefficient. In vivo measurements were performed on five healthy volunteers to monitor spatial changes in calf muscle (medial and lateral gastrocnemius; MG, LG) oxygen saturation (SmO2) and total haemoglobin concentration (tHb) during dynamic plantar flexion exercise performed at 50% of the maximal voluntary contraction. At rest SmO2 was 73.0 ± 0.9 and 70.5 ± 1.7% in MG and LG, respectively (P = 0.045). At the end of the exercise, SmO2 decreased (69.1 ± 1.8 and 63.8 ± 2.1% in MG and LG, respectively; P muscle SmO2 and tHb.

  10. Mapping of calf muscle oxygenation and haemoglobin content during dynamic plantar flexion exercise by multi-channel time-resolved near-infrared spectroscopy

    International Nuclear Information System (INIS)

    Torricelli, Alessandro; Quaresima, Valentina; Pifferi, Antonio; Biscotti, Giovanni; Spinelli, Lorenzo; Taroni, Paola; Ferrari, Marco; Cubeddu, Rinaldo

    2004-01-01

    A compact and fast multi-channel time-resolved near-infrared spectroscopy system for tissue oximetry was developed. It employs semiconductor laser and fibre optics for delivery of optical signals. Photons are collected by eight 1 mm fibres and detected by a multianode photomultiplier. A time-correlated single photon counting board is used for the parallel acquisition of time-resolved reflectance curves. Estimate of the reduced scattering coefficient is achieved by fitting with a standard model of diffusion theory, while the modified Lambert-Beer law is used to assess the absorption coefficient. In vivo measurements were performed on five healthy volunteers to monitor spatial changes in calf muscle (medial and lateral gastrocnemius; MG, LG) oxygen saturation (SmO 2 ) and total haemoglobin concentration (tHb) during dynamic plantar flexion exercise performed at 50% of the maximal voluntary contraction. At rest SmO 2 was 73.0 ± 0.9 and 70.5 ± 1.7% in MG and LG, respectively (P = 0.045). At the end of the exercise, SmO 2 decreased (69.1 ± 1.8 and 63.8 ± 2.1% in MG and LG, respectively; P 2 and tHb

  11. Multiplex multivariate recurrence network from multi-channel signals for revealing oil-water spatial flow behavior.

    Science.gov (United States)

    Gao, Zhong-Ke; Dang, Wei-Dong; Yang, Yu-Xuan; Cai, Qing

    2017-03-01

    The exploration of the spatial dynamical flow behaviors of oil-water flows has attracted increasing interests on account of its challenging complexity and great significance. We first technically design a double-layer distributed-sector conductance sensor and systematically carry out oil-water flow experiments to capture the spatial flow information. Based on the well-established recurrence network theory, we develop a novel multiplex multivariate recurrence network (MMRN) to fully and comprehensively fuse our double-layer multi-channel signals. Then we derive the projection networks from the inferred MMRNs and exploit the average clustering coefficient and the spectral radius to quantitatively characterize the nonlinear recurrent behaviors related to the distinct flow patterns. We find that these two network measures are very sensitive to the change of flow states and the distributions of network measures enable to uncover the spatial dynamical flow behaviors underlying different oil-water flow patterns. Our method paves the way for efficiently analyzing multi-channel signals from multi-layer sensor measurement system.

  12. Large area multi-channel plasmonic absorber based on the touching triangular dimers fabricated by angle controlled colloidal nanolithography

    Science.gov (United States)

    Hamidi, S. M.; Behjati, S.

    2018-02-01

    Here we introduce large area plasmonic touching triangular dimers by angle controlled colloidal nanolithography to use them as an efficient multi channel absorber and also high figure of merit sensors. For this purpose, we coated gold thin films onto nanometric and also micrometric polystyrene hexagonal closed packed masks in different deposition angles and also diverse substrate polar angles. Our prepared samples, after remove masks, show large area touching triangular pattern with different inter particle distances in greater polar angles. To get more sense about optical response of the samples such as transmittance and also electric field distribution, we use finite difference time domain method in simulation part. The transmittance plot shows one narrow or multi-channel adjustable deep depend on inter-particle distances which can be controlled by azimuthally angle in nano lithography process. Also, due to the isoelliptical points in the transmittance spectra; we can see the bright and dark plasmon modes coupling and thus the Fano like resonance takes place in the optical spectral region which is very useful for refractive index measurement.

  13. Multi-channel Andreev reflection in Co-W nanocontacts fabricated using focused electron/ion beam induced deposition.

    Science.gov (United States)

    Sharma, N; Vugts, P; Daniels, C; Keuning, W; Kohlhepp, J T; Kurnosikov, O; Koopmans, B

    2014-12-12

    We report multi-channel electron transport in nano-contacts fabricated using focused electron beam induced deposited (FEBID) cobalt and focused ion beam induced deposited (FIBID) tungsten. Anomalous Andreev reflection (AR) effect is observed to which the conventional Blonder-Tinkham-Klapwijk (BTK) fit cannot be applied. In specific, we have observed multiple number of shoulders near the AR peak, whose origin is unknown in literature. We explain this effect based on a simple model that takes into account the material properties of the FIBID grown W superconductor, as well as the specific interface properties that are an outcome of using FEBID/FIBID as a fabrication technique. We show that numerical calculations using the BTK approximation based on the consideration of multiple channels generate similar shoulders as we observed in the AR experiments. Electrical measurements and x-ray photoemission spectroscopy carried out on FIBID W deposits puts additional evidence towards multi-channel current transport occuring at the interface of the nanocontacts.

  14. Fluorescence-based Sensing of 2,4,6-Trinitrotoluene (TNT Using a Multi-channeled Poly(methyl methacrylate (PMMA Microimmunosensor

    Directory of Open Access Journals (Sweden)

    Anne W. Kusterbeck

    2010-01-01

    Full Text Available Fluorescence immunoassays employing monoclonal antibodies directed against the explosive 2,4,6-trinitrotoluene (TNT were conducted in a multi-channel microimmunosensor. The multi-channel microimmunosensor was prepared in poly (methyl methacrylate (PMMA via hot embossing from a brass molding tool. The multi-channeled microfluidic device was sol-gel coated to generate a siloxane surface that provided a scaffold for antibody immobilization. AlexaFluor-cadaverine-trinitrobenzene (AlexaFluor-Cad-TNB was used as the reporter molecule in a displacement immunoassay. The limit of detection was 1-10 ng/mL (ppb with a linear dynamic range that covered three orders of magnitude. In addition, antibody crossreactivity was investigated using hexahydro-1,3,5-triazine (RDX, HMX, 2,4-dinitrotoluene (DNT, 4-nitrotoluene (4-NT and 2-amino-4,6-DNT.

  15. Monitoring of active layer dynamics at a permafrost site on Svalbard using multi-channel ground-penetrating radar

    Directory of Open Access Journals (Sweden)

    S. Westermann

    2010-11-01

    Full Text Available Multi-channel ground-penetrating radar is used to investigate the late-summer evolution of the thaw depth and the average soil water content of the thawed active layer at a high-arctic continuous permafrost site on Svalbard, Norway. Between mid of August and mid of September 2008, five surveys have been conducted in gravelly soil over transect lengths of 130 and 175 m each. The maximum thaw depths range from 1.6 m to 2.0 m, so that they are among the deepest thaw depths recorded in sediments on Svalbard so far. The thaw depths increase by approximately 0.2 m between mid of August and beginning of September and subsequently remain constant until mid of September. The thaw rates are approximately constant over the entire length of the transects within the measurement accuracy of about 5 to 10 cm. The average volumetric soil water content of the thawed soil varies between 0.18 and 0.27 along the investigated transects. While the measurements do not show significant changes in soil water content over the first four weeks of the study, strong precipitation causes an increase in average soil water content of up to 0.04 during the last week. These values are in good agreement with evapotranspiration and precipitation rates measured in the vicinity of the the study site. While we cannot provide conclusive reasons for the detected spatial variability of the thaw depth at the study site, our measurements show that thaw depth and average soil water content are not directly correlated.

    The study demonstrates the potential of multi-channel ground-penetrating radar for mapping thaw depth in permafrost areas. The novel non-invasive technique is particularly useful when the thaw depth exceeds 1.5 m, so that it is hardly accessible by manual probing. In addition, multi-channel ground-penetrating radar holds potential for mapping the latent heat content of the active layer and for estimating weekly to monthly averages of the ground heat flux during the

  16. A Multi-Channel Low-Power System-on-Chip for in Vivo Recording and Wireless Transmission of Neural Spikes

    Directory of Open Access Journals (Sweden)

    Alessandro Sottocornola Spinelli

    2012-09-01

    Full Text Available This paper reports a multi-channel neural spike recording system-on-chip with digital data compression and wireless telemetry. The circuit consists of 16 amplifiers, an analog time-division multiplexer, a single 8 bit analog-to-digital converter, a digital signal compression unit and a wireless transmitter. Although only 16 amplifiers are integrated in our current die version, the whole system is designed to work with 64, demonstrating the feasibility of a digital processing and narrowband wireless transmission of 64 neural recording channels. Compression of the raw data is achieved by detecting the action potentials (APs and storing 20 samples for each spike waveform. This compression method retains sufficiently high data quality to allow for single neuron identification (spike sorting. The 400 MHz transmitter employs a Manchester-Coded Frequency Shift Keying (MC-FSK modulator with low modulation index. In this way, a 1:25 Mbit/s data rate is delivered within a limited band of about 3 MHz. The chip is realized in a 0:35 m AMS CMOS process featuring a 3 V power supply with an area of 3:1 2:7 mm2. The achieved transmission range is over 10 m with an overall power consumption for 64 channels of 17:2 mW. This figure translates into a power budget of 269 W per channel, in line with published results but allowing a larger transmission distance and more efficient bandwidth occupation of the wireless link. The integrated circuit was mounted on a small and light board to be used during neuroscience experiments with freely-behaving rats. Powered by 2 AAA batteries, the system can continuously work for more than 100 hours allowing for long-lasting neural spike recordings.

  17. Design of a Compact Wireless Multi-Channel High Area-Efficient Stimulator with Arbitrary Channel Configuration

    Directory of Open Access Journals (Sweden)

    Yuwei Zhang

    2017-12-01

    Full Text Available This paper presents the design of a wireless, implantable, multi-channel, programmable stimulator with arbitrary channel combination. A novel channel management module using a switch array is presented, enabling arbitrary channel configuration with a silicon area reduction of 81%. The chip was fabricated in a 0.18- μ m Taiwan semiconductor manufacturing company (TSMC high voltage (HV complementary metal–oxide semiconductor (CMOS technology. A stimulator system was realized using the proposed integrated circuit (IC. A wireless communication link was established between a specified Android-based graphical user interface (GUI and the proposed device for control of the stimulation pattern and wireless battery charging. The size of the entire system occupies a volume of only 14 mm × 14 mm × 4 mm (without the battery. Experimental results demonstrated a successful independent configuration between different channels, as well as an arbitrary channel combination, as expected.

  18. Multi Channels PWM Controller for Thermoelectric Cooler Using a Programmable Logic Device and Lab-Windows CVI

    Directory of Open Access Journals (Sweden)

    Eli FLAXER

    2008-09-01

    Full Text Available We present a complete design of a multi channels PID controller for Thermoelectric Cooler (TEC using a pulse width modulation (PWM technique implemented by a dedicated programmable logic device (PLD programmed by VHDL. The PID control loop is implemented by software written by National Instrument Lab-Windows CVI. Due to the fact that the implementation is by a VHDL and PLD the design is modular, as a result, the circuit is very compact in size and very low cost as compared to any commercial product. In addition, since the control loop is implemented by software running on a personal computer (PC using a C language, it is easy to adjust the controller to various environmental conditions and for a width range of sensors like: a thermo couple (TC, thermistor, resistance temperature detectors (RTD etc. We demonstrate the performance of this circuit as a controller for a small incubator using thermistor as the temperature sensor.

  19. Multi-channel photon migration study in visible Chinese human muscle for optical detection of deep vein thrombosis

    Science.gov (United States)

    Sun, Yunlong; Li, Ting

    2016-03-01

    Deep vein thrombosis (DVT) always induced venous thrombosis. Most cases of venous thrombosis were induced by deep vein thrombosis (DVT), with high incidence rate of >60% in >60 years old people. Near-infrared spectroscopy (NIRS) were reported recently to be an intriguing and potential technique in detecting DVT in clinics. However, the photon transport is still unclear, which is crucial for the image reconstruction of the updated development called as NIRS-based DVT imager. Here we employed the Monte Carlo simulation software for 3D voxelized media (MCVM) and the Visible Chinese Human (VCH) model, which segmentation is finest in the world, to simulate multi-channel photon migration in calf muscle. And the image reconstruction of DVT hemodynamic distribution was achieved. This study, for the first time, provides the most realistic 3-D multichannel photon migration for NIRS study on DVT, and explored the image reconstruction for furtherly developing a NIRS-based DVT imager.

  20. New approach to information fusion for Lipschitz classifiers ensembles: Application in multi-channel C-OTDR-monitoring systems

    Energy Technology Data Exchange (ETDEWEB)

    Timofeev, Andrey V.; Egorov, Dmitry V. [LPP “EqualiZoom”, Astana, 010000 (Kazakhstan)

    2016-06-08

    This paper presents new results concerning selection of an optimal information fusion formula for an ensemble of Lipschitz classifiers. The goal of information fusion is to create an integral classificatory which could provide better generalization ability of the ensemble while achieving a practically acceptable level of effectiveness. The problem of information fusion is very relevant for data processing in multi-channel C-OTDR-monitoring systems. In this case we have to effectively classify targeted events which appear in the vicinity of the monitored object. Solution of this problem is based on usage of an ensemble of Lipschitz classifiers each of which corresponds to a respective channel. We suggest a brand new method for information fusion in case of ensemble of Lipschitz classifiers. This method is called “The Weighing of Inversely as Lipschitz Constants” (WILC). Results of WILC-method practical usage in multichannel C-OTDR monitoring systems are presented.

  1. Multi-channel up-conversion infrared spectrometer and method of detecting a spectral distribution of light

    DEFF Research Database (Denmark)

    2015-01-01

    A multi-channel infrared spectrometer for detecting an infrared spectrum of light received from an object. The spectrometer comprises a wavelength converter system comprising a nonlinear material and having an input side and an output side. The wavelength converter system comprises at least a first...... on the first side into light in a second output wavelength range output on the second side. The spectrometer further comprises a demultiplexer configured for demultiplexing light in the first up-conversion channel and light in the second up-conversion channel. The demultiplexer is located on the first side...... or the second side of the wavelength converter system. Finally, the spectrometer comprises a spatially resolved detector arranged in the image plane to detect light in the first output wavelength range and second output wavelength range output of the wavelength converter system....

  2. A modular architecture for multi-channel external cavity quantum cascade laser-based chemical sensors: a systems approach

    Energy Technology Data Exchange (ETDEWEB)

    Taubman, Matthew S.; Myers, Tanya L.; Bernacki, Bruce E.; Stahl, Robert D.; Cannon, Bret D.; Schiffern, John T.; Phillips, Mark C.

    2012-04-01

    A multi-channel laser-based chemical sensor platform is presented, in which a modular architecture allows the exchange of complete sensor channels without disruption to overall operation. Each sensor channel contains custom optical and electronics packages, which can be selected to access laser wavelengths, interaction path lengths and modulation techniques optimal for a given application or mission. Although intended primarily to accommodate mid-infrared (MIR) external cavity quantum cascade lasers (ECQCLs)and astigmatic Herriott cells, channels using visible or near infrared (NIR) lasers or other gas cell architectures can also be used, making this a truly versatile platform. Analog and digital resources have been carefully chosen to facilitate small footprint, rapid spectral scanning, ow-noise signal recovery, failsafe autonomous operation, and in-situ chemometric data analysis, storage and transmission. Results from the demonstration of a two-channel version of this platform are also presented.

  3. Smart multi-channel two-dimensional micro-gas chromatography for rapid workplace hazardous volatile organic compounds measurement.

    Science.gov (United States)

    Liu, Jing; Seo, Jung Hwan; Li, Yubo; Chen, Di; Kurabayashi, Katsuo; Fan, Xudong

    2013-03-07

    We developed a novel smart multi-channel two-dimensional (2-D) micro-gas chromatography (μGC) architecture that shows promise to significantly improve 2-D μGC performance. In the smart μGC design, a non-destructive on-column gas detector and a flow routing system are installed between the first dimensional separation column and multiple second dimensional separation columns. The effluent from the first dimensional column is monitored in real-time and decision is then made to route the effluent to one of the second dimensional columns for further separation. As compared to the conventional 2-D μGC, the greatest benefit of the smart multi-channel 2-D μGC architecture is the enhanced separation capability of the second dimensional column and hence the overall 2-D GC performance. All the second dimensional columns are independent of each other, and their coating, length, flow rate and temperature can be customized for best separation results. In particular, there is no more constraint on the upper limit of the second dimensional column length and separation time in our architecture. Such flexibility is critical when long second dimensional separation is needed for optimal gas analysis. In addition, the smart μGC is advantageous in terms of elimination of the power intensive thermal modulator, higher peak amplitude enhancement, simplified 2-D chromatogram re-construction and potential scalability to higher dimensional separation. In this paper, we first constructed a complete smart 1 × 2 channel 2-D μGC system, along with an algorithm for automated control/operation of the system. We then characterized and optimized this μGC system, and finally employed it in two important applications that highlight its uniqueness and advantages, i.e., analysis of 31 workplace hazardous volatile organic compounds, and rapid detection and identification of target gas analytes from interference background.

  4. Towards a context-aware multi-channel messaging model for African banks: preliminary investigations

    CSIR Research Space (South Africa)

    Salami, O

    2016-05-01

    Full Text Available Technological advancements have provided Banks several means of sending messages to their customers. In the context of business-to-customer interaction, Single Channel Messaging (SCM) model is prominently used by most Banks in Africa. SCM...

  5. Mapping of calf muscle oxygenation and haemoglobin content during dynamic plantar flexion exercise by multi-channel time-resolved near-infrared spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Torricelli, Alessandro [INFM-Dipartimento di Fisica and IFN-CNR, Politecnico di Milano, Piazza Leonardo da Vinci 32, I-20133 Milan (Italy); Quaresima, Valentina [Department of Biomedical Sciences and Technologies, University of L' Aquila, I-67100 L' Aquila (Italy); Pifferi, Antonio [INFM-Dipartimento di Fisica and IFN-CNR, Politecnico di Milano, Piazza Leonardo da Vinci 32, I-20133 Milan (Italy); Biscotti, Giovanni [INFM-Dipartimento di Fisica and IFN-CNR, Politecnico di Milano, Piazza Leonardo da Vinci 32, I-20133 Milan (Italy); Spinelli, Lorenzo [INFM-Dipartimento di Fisica and IFN-CNR, Politecnico di Milano, Piazza Leonardo da Vinci 32, I-20133 Milan (Italy); Taroni, Paola [INFM-Dipartimento di Fisica and IFN-CNR, Politecnico di Milano, Piazza Leonardo da Vinci 32, I-20133 Milan (Italy); Ferrari, Marco [Department of Biomedical Sciences and Technologies, University of L' Aquila, I-67100 L' Aquila (Italy); Cubeddu, Rinaldo [INFM-Dipartimento di Fisica and IFN-CNR, Politecnico di Milano, Piazza Leonardo da Vinci 32, I-20133 Milan (Italy)

    2004-03-07

    A compact and fast multi-channel time-resolved near-infrared spectroscopy system for tissue oximetry was developed. It employs semiconductor laser and fibre optics for delivery of optical signals. Photons are collected by eight 1 mm fibres and detected by a multianode photomultiplier. A time-correlated single photon counting board is used for the parallel acquisition of time-resolved reflectance curves. Estimate of the reduced scattering coefficient is achieved by fitting with a standard model of diffusion theory, while the modified Lambert-Beer law is used to assess the absorption coefficient. In vivo measurements were performed on five healthy volunteers to monitor spatial changes in calf muscle (medial and lateral gastrocnemius; MG, LG) oxygen saturation (SmO{sub 2}) and total haemoglobin concentration (tHb) during dynamic plantar flexion exercise performed at 50% of the maximal voluntary contraction. At rest SmO{sub 2} was 73.0 {+-} 0.9 and 70.5 {+-} 1.7% in MG and LG, respectively (P = 0.045). At the end of the exercise, SmO{sub 2} decreased (69.1 {+-} 1.8 and 63.8 {+-} 2.1% in MG and LG, respectively; P < 0.01). The LG desaturation was greater than the MG desaturation (P < 0.02). These results strengthen the role of time-resolved near-infrared spectroscopy as a powerful tool for investigating the spatial and temporal features of muscle SmO{sub 2} and tHb.

  6. A hazard-independent approach for the standardised multi-channel dissemination of warning messages

    Science.gov (United States)

    Esbri Palomares, M. A.; Hammitzsch, M.; Lendholt, M.

    2012-04-01

    capabilities of different dissemination channels such as SMS, email and television, have bearing on the information processing required for delivery and consumption of a DEWS EDXL-DE/CAP message over each dissemination channel. These messages may include additional information in the form of maps, graphs, documents, sensor observations, etc. Therefore, the generated messages are pre-processed by channel adaptors in the information dissemination services converting it into a format that is suitable for end-to-end delivery over the dissemination channels without any semantic distortion. The approach followed by DEWS for disseminating warnings not only relies on traditional communication ways used by the already established early warnings such as the delivery of faxes and phone calls but takes into consideration the use of other broadly used communication channels such as SMS, email, narrowcast and broadcast television, instant messaging, Voice over IP, and radio. It also takes advantage of social media channels like RSS feeds, Facebook, Twitter, etc., enabling a multiplier effect, like in the case of radio and television, and thus allowing to create mash-ups by aggregating other sources of information to the original message. Finally, status information is also important in order to assess and understand whether the process of disseminating the warning to the message consumers has been successfully completed or the process failed at some point of the dissemination chain. To that end, CAP-based messages generated within the information dissemination services provide the semantics for those fields that are of interest within the context of reporting the warning dissemination status in DEWS.

  7. New channels, new possibilities : A typology and classification of social robots and their role in multi-channel public service delivery

    NARCIS (Netherlands)

    Pieterson, Willem Jan; Ebbers, Wolfgang E.; Madsen, Christian Ostergaard; Janssen, Marijn; Axelsson, Karin; Glassey, Olivier; Klievink, Bram; Krimmer, Robert; Lindgren, Ida; Parycek, Peter; Scholl, Hans J.; Trutnev, Dmitrii

    2017-01-01

    In this contribution we discuss the characteristics of what we call the fourth generation of public sector service channels: social robots. Based on a review of relevant literature we discuss their characteristics and place into multi-channel models of service delivery. We argue that social robots

  8. Multi-Objective Clustering Optimization for Multi-Channel Cooperative Spectrum Sensing in Heterogeneous Green CRNs

    KAUST Repository

    Celik, Abdulkadir

    2016-06-27

    In this paper, we address energy efficient (EE) cooperative spectrum sensing policies for large scale heterogeneous cognitive radio networks (CRNs) which consist of multiple primary channels and large number of secondary users (SUs) with heterogeneous sensing and reporting channel qualities. We approach this issue from macro and micro perspectives. Macro perspective groups SUs into clusters with the objectives: 1) total energy consumption minimization; 2) total throughput maximization; and 3) inter-cluster energy and throughput fairness. We adopt and demonstrate how to solve these using the nondominated sorting genetic algorithm-II. The micro perspective, on the other hand, operates as a sub-procedure on cluster formations decided by the macro perspective. For the micro perspectives, we first propose a procedure to select the cluster head (CH) which yields: 1) the best CH which gives the minimum total multi-hop error rate and 2) the optimal routing paths from SUs to the CH. Exploiting Poisson-Binomial distribution, a novel and generalized K-out-of-N voting rule is developed for heterogeneous CRNs to allow SUs to have different local detection performances. Then, a convex optimization framework is established to minimize the intra-cluster energy cost by jointly obtaining the optimal sensing durations and thresholds of feature detectors for the proposed voting rule. Likewise, instead of a common fixed sample size test, we developed a weighted sample size test for quantized soft decision fusion to obtain a more EE regime under heterogeneity. We have shown that the combination of proposed CH selection and cooperation schemes gives a superior performance in terms of energy efficiency and robustness against reporting error wall.

  9. Regional brain blood flow in mouse: quantitative measurement using a single-pass radio-tracer method and a mathematical algorithm.

    Science.gov (United States)

    Xu, K; Radhakrishnan, K; Serhal, A; Allen, F; Lamanna, J C; Puchowicz, M A

    2011-01-01

    We have developed a reliable experimental method for measuring local regional cerebral blood flows in anesthetized mice. This method is an extension of the well-established single-pass dual-label indicator method for simultaneously measuring blood flow and glucose influx in rat brains. C57BL6J mice (n = 10) were anesthetized and regional blood flows (ml/min/g) were measured using the radio-tracer method. To test the sensitivity of this method we used a mathematical algorithm to predict the blood flows and compared the two sets of results.Measured regional blood flows between 0.7 and 1.7 ml/min/g were similar to those we have previously reported in the rat. The predicted blood flows using an assumed linearly increasing arterial tracer concentration-versus-time profile (that is, a ramp) were similar to the values measured in the physiological experiments (R(2) 0.99; slope 0.91). Thus,measurements of local regional cerebral blood flow in anesthetized mice using a single-pass radio-tracer method appear to be reliable.

  10. Discourse segmentation and the management of multiple tasks in single episodes of air traffic controller-pilot spoken radio communication

    Directory of Open Access Journals (Sweden)

    Paul A. Falzon

    2009-06-01

    Full Text Available Episodes of VHF radio-mediated pilot-controller spoken communication in which multiple tasks are conducted are engendered in and through the skilful deployment and combination, by the parties to the talk, of multiple orders of discourse segmentation. These orders of segmentation are manifest at the levels of transmission design and sequential organisation. Both of these features are analysed from a Conversation Analytic standpoint in order to track their segment by segment genesis, development and completion. From the analysis it emerges that in addition to the serial type of sequential organisations described by Schegloff (1986, there exists an alternative form of organisation that enables tasks to be managed in a quasi-parallel manner, and which affords controllers and pilots a number of practical advantages in the conduct of their radio-mediated service encounters.Cet article présente des extraits d’échanges oraux entre pilots et contrôleurs du ciel via la radio VHF. On peut y voir comment le déploiement et la combinaison habile de plusieurs ordres de segmentation discursive, engageant les deux coénonciateurs de la conversation, leur permet d’accomplir des tâches multiples. Ces ordres de segmentation se manifestent aux niveaux du plan de la transmission et de l’organisation séquentielle. Ces deux niveaux sont envisagées du point de vue de l’analyse conversationnelle dans le but d’examiner, segment après segment, comment ils se mettent en place, se développent puis prennent fin. Notre étude montre que, outre le type sériel d’organisations séquentielles décrit par Schegloff (1986, il existe une forme alternative d’organisation qui permet de gérer les tâches de manière quasi parallèle, et qui fournit aux contrôleurs aériens ainsi qu’aux pilotes de nombreux avantages pratiques dans la conduite de leurs radio.

  11. Passive ultra high frequency radio frequency identification systems for single-item identification in food supply chains

    Directory of Open Access Journals (Sweden)

    Paolo Barge

    2017-02-01

    Full Text Available In the food industry, composition, size, and shape of items are much less regular than in other commodities sectors. In addition, a wide variety of packaging, composed by different materials, is employed. As material, size and shape of items to which the tag should be attached strongly influence the minimum power requested for tag functioning, performance improvements can be achieved only selecting suitable radio frequency (RF identifiers for the specific combination of food product and packaging. When dealing with logistics units, the dynamic reading of a vast number of tags could originate simultaneous broadcasting of signals (tag-to-tag collisions that could affect reading rates and the overall reliability of the identification procedure. This paper reports the results of an analysis of the reading performance of ultra high frequency radio frequency identification systems for multiple static and dynamic electronic identification of food packed products in controlled conditions. Products were considered when arranged on a logistics pallet. The effects on reading rate of different factors, among which the product type, the gate configuration, the field polarisation, the power output of the RF reader, the interrogation protocol configuration as well as the transit speed, the number of tags and their interactions were statistically analysed and compared.

  12. Development and field example of multi channel surface wave data acquisition and processing system (SWS-1); Multi channel hyomenha data shutoku shori system (SWS-1) no kaihatsu to jikkenrei

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Y. [Huashui Institute of Geophysical Exploration, (China); Wang, Z. [Bureauof Engineering MGMR, (China); Zhang, Z [STG Corp., (China); Tanaka, Y.

    1996-05-01

    A report is given here about the use of a newly-developed multi-channel surface wave data acquisition and processing system different from the conventional surface wave exploration device. This system enables the on-site pickup of a dispersion curve out of the multi-component surface wave data and, in the analysis of underground structure, performs the forward modeling and inversion. The system, furthermore, acquires and analyzes the data obtained from reflection earthquake exploration and constant microtremor observation. During a survey conducted along the highway from Port Ren-un to Xuzhou, China, estimation of the basement boundary was made by use of dynamite, and what was obtained agreed with the result of boring though with an error of 3m. In addition, this system could probe levels deeper than 100m using the instantaneous Rayleigh wave exploration method. This system and the conventional surface exploration device were compared in a soft ground in Fukui Prefecture, the former using a 10kg hammer and the latter using a 350kg exciter, when it was verified that the results produced by both techniques excellently agree with the geologic columnar section and changes in the N-value. 4 refs., 4 figs.

  13. Radio Mariackie

    OpenAIRE

    Tytko, Marek Mariusz

    1993-01-01

    Tekst dotyczy początków katolickiego Radia Mariackiego w Krakowie w 1993 r. The text concerns the begining of the Mariackie Radio [The Mariackie Broadcasting, the Maria's Radio Station, the Maria's Broadcasting, the Maria's Radio) in Cracow 1993.

  14. Digital multi-channel stabilization of four-mode phase-sensitive parametric multicasting.

    Science.gov (United States)

    Liu, Lan; Tong, Zhi; Wiberg, Andreas O J; Kuo, Bill P P; Myslivets, Evgeny; Alic, Nikola; Radic, Stojan

    2014-07-28

    Stable four-mode phase-sensitive (4MPS) process was investigated as a means to enhance two-pump driven parametric multicasting conversion efficiency (CE) and signal to noise ratio (SNR). Instability of multi-beam, phase sensitive (PS) device that inherently behaves as an interferometer, with output subject to ambient induced fluctuations, was addressed theoretically and experimentally. A new stabilization technique that controls phases of three input waves of the 4MPS multicaster and maximizes CE was developed and described. Stabilization relies on digital phase-locked loop (DPLL) specifically was developed to control pump phases to guarantee stable 4MPS operation that is independent of environmental fluctuations. The technique also controls a single (signal) input phase to optimize the PS-induced improvement of the CE and SNR. The new, continuous-operation DPLL has allowed for fully stabilized PS parametric broadband multicasting, demonstrating CE improvement over 20 signal copies in excess of 10 dB.

  15. Multi-Channel Optical Coherence Elastography Using Relative and Absolute Shear-Wave Time of Flight.

    Directory of Open Access Journals (Sweden)

    Eli Elyas

    Full Text Available Elastography, the imaging of elastic properties of soft tissues, is well developed for macroscopic clinical imaging of soft tissues and can provide useful information about various pathological processes which is complementary to that provided by the original modality. Scaling down of this technique should ply the field of cellular biology with valuable information with regard to elastic properties of cells and their environment. This paper evaluates the potential to develop such a tool by modifying a commercial optical coherence tomography (OCT device to measure the speed of shear waves propagating in a three-dimensional (3D medium. A needle, embedded in the gel, was excited to vibrate along its long axis and the displacement as a function of time and distance from the needle associated with the resulting shear waves was detected using four M-mode images acquired simultaneously using a commercial four-channel swept-source OCT system. Shear-wave time of arrival (TOA was detected by tracking the axial OCT-speckle motion using cross-correlation methods. Shear-wave speed was then calculated from inter-channel differences of TOA for a single burst (the relative TOA method and compared with the shear-wave speed determined from positional differences of TOA for a single channel over multiple bursts (the absolute TOA method. For homogeneous gels the relative method provided shear-wave speed with acceptable precision and accuracy when judged against the expected linear dependence of shear modulus on gelatine concentration (R2 = 0.95 and ultimate resolution capabilities limited by 184μm inter-channel distance. This overall approach shows promise for its eventual provision as a research tool in cancer cell biology. Further work is required to optimize parameters such as vibration frequency, burst length and amplitude, and to assess the lateral and axial resolutions of this type of device as well as to create 3D elastograms.

  16. Reconfigurable digital receiver for 8PSK subcarrier multiplexed and 16QAM single carrier phase‐modulated radio over fiber links

    DEFF Research Database (Denmark)

    Guerrero Gonzalez, Neil; Zibar, Darko; Yu, Xianbin

    2011-01-01

    A reconfigurable digital receiver based on the k‐means algorithm is proposed for phase‐modulated subcarrier multiplexed (SCM) and quadrature amplitude‐modulated single carrier, phase‐modulated radio‐over‐fiber links. We report successful demodulation after 40 km single mode fiber transmission...

  17. A Multi-Channel Opto-Electronic Sensor to Accurately Monitor Heart Rate against Motion Artefact during Exercise

    Directory of Open Access Journals (Sweden)

    Abdullah Alzahrani

    2015-10-01

    Full Text Available This study presents the use of a multi-channel opto-electronic sensor (OEPS to effectively monitor critical physiological parameters whilst preventing motion artefact as increasingly demanded by personal healthcare. The aim of this work was to study how to capture the heart rate (HR efficiently through a well-constructed OEPS and a 3-axis accelerometer with wireless communication. A protocol was designed to incorporate sitting, standing, walking, running and cycling. The datasets collected from these activities were processed to elaborate sport physiological effects. t-test, Bland-Altman Agreement (BAA, and correlation to evaluate the performance of the OEPS were used against Polar and Mio-Alpha HR monitors. No differences in the HR were found between OEPS, and either Polar or Mio-Alpha (both p > 0.05; a strong correlation was found between Polar and OEPS (r: 0.96, p < 0.001; the bias of BAA 0.85 bpm, the standard deviation (SD 9.20 bpm, and the limits of agreement (LOA from −17.18 bpm to +18.88 bpm. For the Mio-Alpha and OEPS, a strong correlation was found (r: 0.96, p < 0.001; the bias of BAA 1.63 bpm, SD 8.62 bpm, LOA from −15.27 bpm to +18.58 bpm. These results demonstrate the OEPS to be capable of carrying out real time and remote monitoring of heart rate.

  18. 'Too much, too late': mixed methods multi-channel video recording study of computerized decision support systems and GP prescribing.

    Science.gov (United States)

    Hayward, James; Thomson, Fionagh; Milne, Heather; Buckingham, Susan; Sheikh, Aziz; Fernando, Bernard; Cresswell, Kathrin; Williams, Robin; Pinnock, Hilary

    2013-06-01

    Computerized decision support systems (CDSS) are commonly deployed to support prescribing, although over-riding of alerts by prescribers remains a concern. We aimed to understand how general practitioners (GPs) interact with prescribing CDSS in order to inform deliberation on how better to support prescribing decisions in primary care. Quantitative and qualitative analysis of interactions between GPs, patients, and computer systems using multi-channel video recordings of 112 primary care consultations with eight GPs in three UK practices. 132 prescriptions were issued in the course of 73 of the consultations, of which 81 (61%) attracted at least one alert. Of the total of 117 alerts, only three resulted in the GP checking, but not altering, the prescription. CDSS provided information and safety alerts at the point of generating a prescription. This was 'too much, too late' as the majority of the 'work' of prescribing occurred prior to using the computer. By the time an alert appeared, the GP had formulated the problem(s), potentially spent several minutes considering, explaining, negotiating, and reaching agreement with the patient about the proposed treatment, and had possibly given instructions and printed an information leaflet. CDSS alerts do not coincide with the prescribing workflow throughout the whole GP consultation. Current systems interrupt to correct decisions that have already been taken, rather than assisting formulation of the management plan. CDSS are likely to be more acceptable and effective if the prescribing support is provided much earlier in the process of generating a prescription.

  19. Vehicular Networking Enhancement And Multi-Channel Routing Optimization, Based on Multi-Objective Metric and Minimum Spanning Tree

    Directory of Open Access Journals (Sweden)

    Peppino Fazio

    2013-01-01

    Full Text Available Vehicular Ad hoc NETworks (VANETs represent a particular mobile technology that permits the communication among vehicles, offering security and comfort. Nowadays, distributed mobile wireless computing is becoming a very important communications paradigm, due to its flexibility to adapt to different mobile applications. VANETs are a practical example of data exchanging among real mobile nodes. To enable communications within an ad-hoc network, characterized by continuous node movements, routing protocols are needed to react to frequent changes in network topology. In this paper, the attention is focused mainly on the network layer of VANETs, proposing a novel approach to reduce the interference level during mobile transmission, based on the multi-channel nature of IEEE 802.11p (1609.4 standard. In this work a new routing protocol based on Distance Vector algorithm is presented to reduce the delay end to end and to increase packet delivery ratio (PDR and throughput in VANETs. A new metric is also proposed, based on the maximization of the average Signal-to-Interference Ratio (SIR level and the link duration probability between two VANET nodes. In order to relieve the effects of the co-channel interference perceived by mobile nodes, transmission channels are switched on a basis of a periodical SIR evaluation. A Network Simulator has been used for implementing and testing the proposed idea.

  20. Research on multi - channel interactive virtual assembly system for power equipment under the “VR+” era

    Science.gov (United States)

    Ren, Yilong; Duan, Xitong; Wu, Lei; He, Jin; Xu, Wu

    2017-06-01

    With the development of the “VR+” era, the traditional virtual assembly system of power equipment has been unable to satisfy our growing needs. In this paper, based on the analysis of the traditional virtual assembly system of electric power equipment and the application of VR technology in the virtual assembly system of electric power equipment in our country, this paper puts forward the scheme of establishing the virtual assembly system of power equipment: At first, we should obtain the information of power equipment, then we should using OpenGL and multi texture technology to build 3D solid graphics library. After the completion of three-dimensional modeling, we can use the dynamic link library DLL package three-dimensional solid graphics generation program to realize the modularization of power equipment model library and power equipment model library generated hidden algorithm. After the establishment of 3D power equipment model database, we set up the virtual assembly system of 3D power equipment to separate the assembly operation of the power equipment from the space. At the same time, aiming at the deficiency of the traditional gesture recognition algorithm, we propose a gesture recognition algorithm based on improved PSO algorithm for BP neural network data glove. Finally, the virtual assembly system of power equipment can really achieve multi-channel interaction function.

  1. Developmental changes in frontal lobe function during a verbal fluency task: a multi-channel near-infrared spectroscopy study.

    Science.gov (United States)

    Tando, Tomoko; Kaga, Yoshimi; Ishii, Sayaka; Aoyagi, Kakuro; Sano, Fumikazu; Kanemura, Hideaki; Sugita, Kanji; Aihara, Masao

    2014-11-01

    Near-infrared spectroscopy (NIRS) is commonly used to investigate continuous changes of brain activation and has excellent time resolution. Verbal fluency task (VFT) is widely used as a neuropsychological test of frontal lobe function. The aim of this study was to investigate normal developmental change in frontal lobe function during VFT performance using multi-channel NIRS, specifically focusing on oxygenation hemoglobin (oxyHb) changes. The subjects were 9 adults and 37 childrens who were all healthy right-handed volunteers. Children were divided into four age groups (group A, 6-8 years; group B, 9-11 years; group C, 12-14 years; group D, 15-18 years). The [oxyHb] changes were measured with 22 channels of NIRS during VFT. We defined the frontopolar region as the region of interest for analysis, and calculated the Z-score to compare the data between groups. The task performance changed with age. There were significant differences between group A and other groups. The Z-score of [oxyHb] also significantly increased with age, when comparing adults to groups A and B. The task performances decreased with time in all groups. In contrast, [oxyHb] only continued to increase in the adult group. The verbal retrieval functions begin to mature in early adolescence and continue to grow up to adulthood. Copyright © 2014 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  2. Leveraging accelerated testing of LED drivers to model the reliability of two-stage and multi-channel drivers

    Energy Technology Data Exchange (ETDEWEB)

    Davis, Lynn; Perkins, Curtis; Smith, Aaron; Clark, Terry; Mills, Karmann

    2017-05-30

    The next wave of LED lighting technology is likely to be tunable white lighting (TWL) devices which can adjust the colour of the emitted light between warm white (~ 2700 K) and cool white (~ 6500 K). This type of lighting system uses LED assemblies of two or more colours each controlled by separate driver channels that independently adjust the current levels to achieve the desired lighting colour. Drivers used in TWL devices are inherently more complex than those found in simple SSL devices, due to the number of electrical components in the driver required to achieve this level of control. The reliability of such lighting systems can only be studied using accelerated stress tests (AST) that accelerate the aging process to time frames that can be accommodated in laboratory testing. This paper describes AST methods and findings developed from AST data that provide insights into the lifetime of the main components of one-channel and multi-channel LED devices. The use of AST protocols to confirm product reliability is necessary to ensure that the technology can meet the performance and lifetime requirements of the intended application.

  3. New geological interpretation of multi-channel seismic profiles from the Pacific Margin of the Antarctic Peninsula

    Directory of Open Access Journals (Sweden)

    Okoń Jan

    2016-06-01

    Full Text Available The Polish Geophysical Expedition to West Antarctica in 1979–1980 was carried out by the Institute of Geophysics, Polish Academy of Sciences. Beside deep seismic soundings, 12 multi-channel seismic profiles, with a total length of ca 1000 km have been recorded north and east of the South Shetland Islands and in the Bransfield Strait, but they have never before been completely interpreted and published. All profiles have been processed with modern processing flow including time migration. Profiles crossing the South Shetland Trench revealed distinct reflector inside continental slope, which has been interpreted as border between buried accretionary prism and overlying slope sediments of glacial-marine origin. Profiles in the Bransfield Strait show traces of the Last Glacial Maximum (LGM in the form of glacial foreground valleys, with some of them used as weak spots for young age volcanic intrusions. This paper is the first comprehensive geological interpretation of collected dataset and differences between results from other expeditions are discussed.

  4. Equalization enhanced phase noise in Nyquist-spaced superchannel transmission systems using multi-channel digital back-propagation.

    Science.gov (United States)

    Xu, Tianhua; Liga, Gabriele; Lavery, Domaniç; Thomsen, Benn C; Savory, Seb J; Killey, Robert I; Bayvel, Polina

    2015-09-14

    Superchannel transmission spaced at the symbol rate, known as Nyquist spacing, has been demonstrated for effectively maximizing the optical communication channel capacity and spectral efficiency. However, the achievable capacity and reach of transmission systems using advanced modulation formats are affected by fibre nonlinearities and equalization enhanced phase noise (EEPN). Fibre nonlinearities can be effectively compensated using digital back-propagation (DBP). However EEPN which arises from the interaction between laser phase noise and dispersion cannot be efficiently mitigated, and can significantly degrade the performance of transmission systems. Here we report the first investigation of the origin and the impact of EEPN in Nyquist-spaced superchannel system, employing electronic dispersion compensation (EDC) and multi-channel DBP (MC-DBP). Analysis was carried out in a Nyquist-spaced 9-channel 32-Gbaud DP-64QAM transmission system. Results confirm that EEPN significantly degrades the performance of all sub-channels of the superchannel system and that the distortions are more severe for the outer sub-channels, both using EDC and MC-DBP. It is also found that the origin of EEPN depends on the relative position between the carrier phase recovery module and the EDC (or MC-DBP) module. Considering EEPN, diverse coding techniques and modulation formats have to be applied for optimizing different sub-channels in superchannel systems.

  5. Multi-channel, fiber-based seed pulse distribution system for femtosecond-level synchronized chirped pulse amplifiers.

    Science.gov (United States)

    Horáček, Martin; Indra, Lukáš; Green, Jonathan T; Naylon, Jack A; Tykalewicz, Boguslaw; Novák, Jakub; Batysta, František; Mazanec, Tomáš; Horáček, Jakub; Antipenkov, Roman; Hubka, Zbyněk; Boge, Robert; Bakule, Pavel; Rus, Bedřich

    2017-01-01

    We report on the design and performance of a fiber-based, multi-channel laser amplifier seed pulse distribution system. The device is designed to condition and distribute low energy laser pulses from a mode-locked oscillator to multiple, highly synchronized, high energy amplifiers integrated into a laser beamline. Critical functions such as temporal pulse stretching well beyond 100 ps/nm, pulse picking, and fine control over the pulse delay up to 300 ps are all performed in fiber eliminating the need for bulky and expensive grating stretchers, Pockels cells, and delay lines. These functions are characterized and the system as a whole is demonstrated by seeding two high energy amplifiers in the laser beamline. The design of this system allows for complete computer control of all functions, including tuning of dispersion, and is entirely hands-free. The performance of this device and its subsystems will be relevant to those developing lasers where reliability, size, and cost are key concerns in addition to performance; this includes those developing large-scale laser systems similar to ours and also those developing table-top experiments and commercial systems.

  6. Gait training assisted by multi-channel functional electrical stimulation early after stroke: study protocol for a randomized controlled trial.

    Science.gov (United States)

    van Bloemendaal, Maijke; Bus, Sicco A; de Boer, Charlotte E; Nollet, Frans; Geurts, Alexander C H; Beelen, Anita

    2016-10-01

    Many stroke survivors suffer from paresis of lower limb muscles, resulting in compensatory gait patterns characterised by asymmetries in spatial and temporal parameters and reduced walking capacity. Functional electrical stimulation has been used to improve walking capacity, but evidence is mostly limited to the orthotic effects of peroneal functional electrical stimulation in the chronic phase after stroke. The aim of this study is to investigate the therapeutic effects of up to 10 weeks of multi-channel functional electrical stimulation (MFES)-assisted gait training on the restoration of spatiotemporal gait symmetry and walking capacity in subacute stroke patients. In a proof-of-principle study with a randomised controlled design, 40 adult patients with walking deficits who are admitted for inpatient rehabilitation within 31 days since the onset of stroke are randomised to either MFES-assisted gait training or conventional gait training. Gait training is delivered in 30-minute sessions each workday for up to 10 weeks. The step length symmetry ratio is the primary outcome. Blinded assessors conduct outcome assessments at baseline, every 2 weeks during the intervention period, immediately post intervention and at 3-month follow-up. This study aims to provide preliminary evidence for the feasibility and effectiveness of MFES-assisted gait rehabilitation early after stroke. Results will inform the design of a larger multi-centre trial. This trial is registered at the Netherlands Trial Register (number NTR4762 , registered 28 August 2014).

  7. BDNF gene delivery within and beyond templated agarose multi-channel guidance scaffolds enhances peripheral nerve regeneration

    Science.gov (United States)

    Gao, Mingyong; Lu, Paul; Lynam, Dan; Bednark, Bridget; Campana, W. Marie; Sakamoto, Jeff; Tuszynski, Mark

    2016-12-01

    Objective. We combined implantation of multi-channel templated agarose scaffolds with growth factor gene delivery to examine whether this combinatorial treatment can enhance peripheral axonal regeneration through long sciatic nerve gaps. Approach. 15 mm long scaffolds were templated into highly organized, strictly linear channels, mimicking the linear organization of natural nerves into fascicles of related function. Scaffolds were filled with syngeneic bone marrow stromal cells (MSCs) secreting the growth factor brain derived neurotrophic factor (BDNF), and lentiviral vectors expressing BDNF were injected into the sciatic nerve segment distal to the scaffold implantation site. Main results. Twelve weeks after injury, scaffolds supported highly linear regeneration of host axons across the 15 mm lesion gap. The incorporation of BDNF-secreting cells into scaffolds significantly increased axonal regeneration, and additional injection of viral vectors expressing BDNF into the distal segment of the transected nerve significantly enhanced axonal regeneration beyond the lesion. Significance. Combinatorial treatment with multichannel bioengineered scaffolds and distal growth factor delivery significantly improves peripheral nerve repair, rivaling the gold standard of autografts.

  8. Multi-channel analysis of surface waves MASW of models with high shear-wave velocity contrast

    Science.gov (United States)

    Ivanov, J.; Miller, R.D.; Peterie, S.; Zeng, C.; Xia, J.; Schwenk, T.

    2011-01-01

    We use the multi-channel analysis of surface waves MASW method to analyze synthetic seismic data calculated using models with high shear-wave velocity Vs contrast. The MASW dispersion-curve images of the Rayleigh wave are obtained using various sets of source-offset and spread-size configurations from the synthetic seismic data and compared with the theoretically calculated fundamental- and higher-mode dispersion-curves. Such tests showed that most of the dispersion-curve images are dominated by higher-mode energy at the low frequencies, especially when analyzing data from long receiver offsets and thus significantly divert from numerically expected dispersion-curve trends, which can lead to significant Vs overestimation. Further analysis showed that using data with relatively short spread lengths and source offsets can image the desired fundamental-mode of the Rayleigh wave that matches the numerically expected dispersion-curve pattern. As a result, it was concluded that it might be possible to avoid higher-mode contamination at low frequencies at sites with high Vs contrast by appropriate selection of spread size and seismic source offset. ?? 2011 Society of Exploration Geophysicists.

  9. Do you see what I hear: experiments in multi-channel sound and 3D visualization for network monitoring?

    Science.gov (United States)

    Ballora, Mark; Hall, David L.

    2010-04-01

    Detection of intrusions is a continuing problem in network security. Due to the large volumes of data recorded in Web server logs, analysis is typically forensic, taking place only after a problem has occurred. This paper describes a novel method of representing Web log information through multi-channel sound, while simultaneously visualizing network activity using a 3-D immersive environment. We are exploring the detection of intrusion signatures and patterns, utilizing human aural and visual pattern recognition ability to detect intrusions as they occur. IP addresses and return codes are mapped to an informative and unobtrusive listening environment to act as a situational sound track of Web traffic. Web log data is parsed and formatted using Python, then read as a data array by the synthesis language SuperCollider [1], which renders it as a sonification. This can be done either for the study of pre-existing data sets or in monitoring Web traffic in real time. Components rendered aurally include IP address, geographical information, and server Return Codes. Users can interact with the data, speeding or slowing the speed of representation (for pre-existing data sets) or "mixing" sound components to optimize intelligibility for tracking suspicious activity.

  10. Real-time system design environment for multi-channel high-speed data acquisition system and pattern recognition

    International Nuclear Information System (INIS)

    Crosetto, Dario B.

    1999-01-01

    The Design Real-Time 2.0 software environment provides the user with a set of tools to create a real-time fully programmable system which can sustain a rate of several MHz from multi-channel inputs, can extend processing time in a pipeline stage and can provide a result within a few hundred ns. The tool set allows the user to (a) create applications of different sizes with different throughput and filtering algorithms; (b) select the processor speed, internal bus width, lookup tables, number of input and output result bits for each set of data received at each channel for each algorithm execution; (c) simulate a specific parallel-processing system for a given algorithm on different sets of data; (d) monitor the system in real time via an RS232 interface; (e) create a hardware component (FPGA or ASIC) by means of interfacing to the Electronic Design Automation (EDA) tools. The advantage of these tools is that of allowing simulation, before construction, of an entire programmable high-speed data acquisition and processing system, and selection of the processor speed, bus width and real-time algorithm which is most cost effective for a specific application where general-purpose processors fail in speed and performance. Benefits derived from the use of the novel architecture and cost comparisons with respect to similar designs are also provided

  11. XPS: A multi-channel preamplifier-shaper IC for X-ray spectroscopy

    International Nuclear Information System (INIS)

    Krieger, B.; Kipnis, I.; Ludewigt, B.A.

    1997-11-01

    An integrated circuit featuring 48 channels of charge-sensitive preamplifiers followed by variable-gain pulse shaping amplifiers is being developed as part of an x-ray spectrometer with a highly segmented detector to handle high fluxes in synchrotron experiments. Such detector systems can provide excellent energy resolution combined with one-dimensional spatial information. The IC combines many basic spectroscopy amplifier functions with a low-noise preamplifier section to produce a unique circuit capable of driving conventional ADC modules directly. An important feature of the design is the novel CR-RC 2 pulse shaper. In this section, high-linearity transconductor circuits are required in order to provide a broad range of continuously variable peaking times while still maintaining the linearity and noise performance necessary for x-ray spectroscopy. Reported here are first measurements made on the performance of a 16-channel prototype integrated circuit. At present, the preamplifier-shaper circuit achieves an equivalent input noise of 26 electrons rms at 2 micros peaking time with a 0.2 pF external capacitor, which is similar to the capacitance of a single detector element. The design was fabricated in standard 1.2 microm CMOS technology

  12. Quantifying forearm muscle activity during wrist and finger movements by means of multi-channel electromyography.

    Directory of Open Access Journals (Sweden)

    Marco Gazzoni

    Full Text Available The study of hand and finger movement is an important topic with applications in prosthetics, rehabilitation, and ergonomics. Surface electromyography (sEMG is the gold standard for the analysis of muscle activation. Previous studies investigated the optimal electrode number and positioning on the forearm to obtain information representative of muscle activation and robust to movements. However, the sEMG spatial distribution on the forearm during hand and finger movements and its changes due to different hand positions has never been quantified. The aim of this work is to quantify 1 the spatial localization of surface EMG activity of distinct forearm muscles during dynamic free movements of wrist and single fingers and 2 the effect of hand position on sEMG activity distribution. The subjects performed cyclic dynamic tasks involving the wrist and the fingers. The wrist tasks and the hand opening/closing task were performed with the hand in prone and neutral positions. A sensorized glove was used for kinematics recording. sEMG signals were acquired from the forearm muscles using a grid of 112 electrodes integrated into a stretchable textile sleeve. The areas of sEMG activity have been identified by a segmentation technique after a data dimensionality reduction step based on Non Negative Matrix Factorization applied to the EMG envelopes. The results show that 1 it is possible to identify distinct areas of sEMG activity on the forearm for different fingers; 2 hand position influences sEMG activity level and spatial distribution. This work gives new quantitative information about sEMG activity distribution on the forearm in healthy subjects and provides a basis for future works on the identification of optimal electrode configuration for sEMG based control of prostheses, exoskeletons, or orthoses. An example of use of this information for the optimization of the detection system for the estimation of joint kinematics from sEMG is reported.

  13. Quantifying forearm muscle activity during wrist and finger movements by means of multi-channel electromyography.

    Science.gov (United States)

    Gazzoni, Marco; Celadon, Nicolò; Mastrapasqua, Davide; Paleari, Marco; Margaria, Valentina; Ariano, Paolo

    2014-01-01

    The study of hand and finger movement is an important topic with applications in prosthetics, rehabilitation, and ergonomics. Surface electromyography (sEMG) is the gold standard for the analysis of muscle activation. Previous studies investigated the optimal electrode number and positioning on the forearm to obtain information representative of muscle activation and robust to movements. However, the sEMG spatial distribution on the forearm during hand and finger movements and its changes due to different hand positions has never been quantified. The aim of this work is to quantify 1) the spatial localization of surface EMG activity of distinct forearm muscles during dynamic free movements of wrist and single fingers and 2) the effect of hand position on sEMG activity distribution. The subjects performed cyclic dynamic tasks involving the wrist and the fingers. The wrist tasks and the hand opening/closing task were performed with the hand in prone and neutral positions. A sensorized glove was used for kinematics recording. sEMG signals were acquired from the forearm muscles using a grid of 112 electrodes integrated into a stretchable textile sleeve. The areas of sEMG activity have been identified by a segmentation technique after a data dimensionality reduction step based on Non Negative Matrix Factorization applied to the EMG envelopes. The results show that 1) it is possible to identify distinct areas of sEMG activity on the forearm for different fingers; 2) hand position influences sEMG activity level and spatial distribution. This work gives new quantitative information about sEMG activity distribution on the forearm in healthy subjects and provides a basis for future works on the identification of optimal electrode configuration for sEMG based control of prostheses, exoskeletons, or orthoses. An example of use of this information for the optimization of the detection system for the estimation of joint kinematics from sEMG is reported.

  14. High speed, multi-channel, user programmable digital data acquisition system.

    Energy Technology Data Exchange (ETDEWEB)

    Sabourov, Konstantin [XIA LLC; Hennig, Wolfgang [XIA LLC; Walby, Mark [XIA LLC

    2013-11-18

    As applications for radiation detection become more demanding, and in turn improvements are made in the technology of radiation detection, there is a need for high speed digital detector readout electronics matching these improvements. Specifically, full control over the on-line processing resources of modern digital electronics is desirable so that researchers can develop custom algorithms for special applications.In the proposed effort, the 500 MHz digital readout electronics previously developed by our company will be redesigned to allow user access to the on-line processing resources. In Phase I, the division of online processing into vendor and user firmware sections has been studied on existing hardware. In Phase II, the hardware will be upgraded to better facilitate the division, and the firmware will be restructured into a robust vendor logic block (providing standard functions such as host I/O, on-board memory I/O, energy computation, MCA spectra, timestamps, waveform capture, run statistics, and triggering and timing) and a user logic block for custom algorithms (with templates and examples for frequently used functions). Investigating several options to divide online processing, it was determined that the most promising approach is to “partition” a single FPGA integrated circuit into a vendor and user section, which is supported in newer devices. The analog front end of the existing electronics proved suitable for most applications, in particular high rate measurements with germanium detectors. The design architecture for new electronics was developed, combining one of the new FPGA device with the analog front end.

  15. Design and construction of the 8K multi-channel gamma spectrometer module (ADC+MCD)

    International Nuclear Information System (INIS)

    Vu Xuan Cach; Hoang Thi Ngoc Bich; Truong Van Dat; Pham Ngoc Tuan; Dang Lanh; Tuong Thi Thu Huong; Nguyen Xuan Hai

    2007-01-01

    A multichannel pulse-height analyzer system (MCA) consists of an ADC with 8192 channel performance, a histogramming memory, and a visual display of the histogram, implemented on a Personal Computer (PC). The purpose of the analog-to-digital converter (ADC) is to measure the maximum amplitude of an analog pulse, and convert that value into a digital number. This digital output is a proportional representation of the analog amplitude at the ADC input. The digital ADC outputs are stored in a histogram memory, where each bin represents a pulse height interval and the number of events in each bin represents the number of events in that interval. The combination of ADC, histogramming memory and display functions are the minimum to constitute a multichannel analyzer or MCA based on PC. It is designed and fabricated on a single NIM module. The communication between MCA module and PC implements via USB bus. In our application, performance of the USB standard version 1.1 is good enough for purposes. The application program was designed in LabWIEW 8.0 software. This application is the main display and acquisition software for the MCA module. It is compatible with Windows 98SE/XP. The libraries USB driver, with their supporting files, are in the FTD2XX driver DLL Package and D2XX function 7.0 for LabWIEW supporting. These libraries are used to write custom code to control the MCA module. The 8K MCA module has the main following hardware specifications: ADC Successive-approximation type with sliding scale linearization; resolution: 8192 channels; dead time per event: 5 μs, including memory transfer; integral nonlinearity: ±0.025% over the top 98% of the dynamic range; differential nonlinearity: < ±1% over the top 98% of the dynamic range; data memory: 224 counts per channel (16 millions counts); presets; Real Time/Live Time: 1 to 232(s), Multiples of 1 s; ADC LLD and ULD Aajustable from 0 to 100% of full scale via hardware control; input accepts positive unipolar pulses in

  16. Multi-channel Dual Clocks three-dimensional probability Random Multiple Access protocol for Wireless Public Bus Networks based on RTS/CTS mechanism

    Directory of Open Access Journals (Sweden)

    Zhou Sheng Jie

    2016-01-01

    Full Text Available A MAC protocol for public bus networks, called Bus MAC protocol, designed to provide high quality Internet service for bus passengers. The paper proposed a multi-channel dual clocks three-demission probability random multiple access protocol based on RTS/CTS mechanism, decreasing collisions caused by multiple access from multiple passengers. Use the RTS/CTS mechanism increases the reliability and stability of the system, reducing the collision possibility of the information packets to a certain extent, improves the channel utilization; use the multi-channel mechanism, not only enables the channel load balancing, but also solves the problem of the hidden terminal and exposed terminal. Use the dual clocks mechanism, reducing the system idle time. At last, the different selection of the three-dimensional probabilities can make the system throughput adapt to the network load which could realize the maximum of the system throughput.

  17. THE APPLICATION OF GENERAL THEORY OF ROOT TRAJECTORIES METHODS IN RESEARCH OF MULTI-CHANNEL CONTROL SYSTEM WITH CROSS-CONNECTIONS

    Directory of Open Access Journals (Sweden)

    V. V. Tkachenko

    2016-01-01

    Full Text Available Computer aided research method on the basis of general theory of root trajectories is considered in the frame of study of multi-channel control systems with varying parameters included as cofactors with arbitrary exponents in coefficients of the characteristic equation of the system. Possibilities of the method are demonstrated on the example of constructing stability regions projections on the plane of varying parameters of dual-channel pulse system with cross-connections.

  18. Exploring the complementarity of THz pulse imaging and DCE-MRIs: Toward a unified multi-channel classification and a deep learning framework.

    Science.gov (United States)

    Yin, X-X; Zhang, Y; Cao, J; Wu, J-L; Hadjiloucas, S

    2016-12-01

    We provide a comprehensive account of recent advances in biomedical image analysis and classification from two complementary imaging modalities: terahertz (THz) pulse imaging and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). The work aims to highlight underlining commonalities in both data structures so that a common multi-channel data fusion framework can be developed. Signal pre-processing in both datasets is discussed briefly taking into consideration advances in multi-resolution analysis and model based fractional order calculus system identification. Developments in statistical signal processing using principal component and independent component analysis are also considered. These algorithms have been developed independently by the THz-pulse imaging and DCE-MRI communities, and there is scope to place them in a common multi-channel framework to provide better software standardization at the pre-processing de-noising stage. A comprehensive discussion of feature selection strategies is also provided and the importance of preserving textural information is highlighted. Feature extraction and classification methods taking into consideration recent advances in support vector machine (SVM) and extreme learning machine (ELM) classifiers and their complex extensions are presented. An outlook on Clifford algebra classifiers and deep learning techniques suitable to both types of datasets is also provided. The work points toward the direction of developing a new unified multi-channel signal processing framework for biomedical image analysis that will explore synergies from both sensing modalities for inferring disease proliferation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. Multi-channel and porous SiO@N-doped C rods as anodes for high-performance lithium-ion batteries

    Science.gov (United States)

    Huang, Xiao; Li, Mingqi

    2018-05-01

    To improve the cycling stability and rate capability of SiO electrodes, multi-channel and porous SiO@N-doped C (mp-SiO@N-doped C) rods are fabricated by the combination of electrospinning and heat treatment with the assistance of poly(methyl methacrylate) (PMMA). During annealing, in-situ PMMA degradation and gasification lead to the formation of multi-channel structure and more pores. As anodes for lithium ion batteries, the mp-SiO@N-doped C rods exhibit excellent cycling stability. At a current density of 400 mA g-1, a discharge capacity of 806 mAh g-1 can be kept after 250 cycles, the retention of which is over than 100% versus the initial reversible capacity. Compared with the SiO@N-doped C rods synthesized without the help of PMMA, the mp-SiO@N-doped C rods exhibit more excellent rate capability. The excellent electrochemical performance is attributed to the special structure of the mp-SiO@N-doped C rods. In addition to the conductivity improved by carbon fibers, the multi-channel and porous structures not only make ions/electrons transfer and electrolyte diffusion easier, but also contribute to the structural stability of the electrodes.

  20. Detection of gear cracks in a complex gearbox of wind turbines using supervised bounded component analysis of vibration signals collected from multi-channel sensors

    Science.gov (United States)

    Li, Zhixiong; Yan, Xinping; Wang, Xuping; Peng, Zhongxiao

    2016-06-01

    In the complex gear transmission systems, in wind turbines a crack is one of the most common failure modes and can be fatal to the wind turbine power systems. A single sensor may suffer with issues relating to its installation position and direction, resulting in the collection of weak dynamic responses of the cracked gear. A multi-channel sensor system is hence applied in the signal acquisition and the blind source separation (BSS) technologies are employed to optimally process the information collected from multiple sensors. However, literature review finds that most of the BSS based fault detectors did not address the dependence/correlation between different moving components in the gear systems; particularly, the popular used independent component analysis (ICA) assumes mutual independence of different vibration sources. The fault detection performance may be significantly influenced by the dependence/correlation between vibration sources. In order to address this issue, this paper presents a new method based on the supervised order tracking bounded component analysis (SOTBCA) for gear crack detection in wind turbines. The bounded component analysis (BCA) is a state of art technology for dependent source separation and is applied limitedly to communication signals. To make it applicable for vibration analysis, in this work, the order tracking has been appropriately incorporated into the BCA framework to eliminate the noise and disturbance signal components. Then an autoregressive (AR) model built with prior knowledge about the crack fault is employed to supervise the reconstruction of the crack vibration source signature. The SOTBCA only outputs one source signal that has the closest distance with the AR model. Owing to the dependence tolerance ability of the BCA framework, interfering vibration sources that are dependent/correlated with the crack vibration source could be recognized by the SOTBCA, and hence, only useful fault information could be preserved in

  1. RADIO CINEMA

    OpenAIRE

    JØRGENSEN, MARIA; HALADYN, DENNIS; DIENER, BIRK; REESE, LIV LINDTNER

    2016-01-01

    First article: Radio Cinema has become more and more popular in Copenhagen - escalating since the first Radio Cinema event was held in 2013. Now, it is monthly taking place in Gloria Biograf. The audience meets in the darkened cinema auditory and listens to a curated program of podcasts. In this article we investigate how the experience of participating in a Radio Cinema event feels through the theory of Sarah Pink’s Doing Sensory Ethnography (2009). In the first par...

  2. Terrestrial water storage changes over Xinjiang extracted by combining Gaussian filter and multi-channel singular spectrum analysis from GRACE

    Science.gov (United States)

    Guo, Jinyun; Li, Wudong; Chang, Xiaotao; Zhu, Guangbin; Liu, Xin; Guo, Bin

    2018-01-01

    Water resource management is crucial for the economic and social development of Xinjiang, an arid area located in the Northwest China. In this paper, the time-variations of GRACE-derived monthly gravity field models from Jan. 2003 to Dec. 2013 are analyzed to study the terrestrial water storage (TWS) changes in Xinjiang using the multi-channel singular spectrum analysis (MSSA) with a Gaussian smoothing radius of 400 km. As an extended singular spectrum analysis (SSA), MSSA is more flexible to deal with multivariate time series in terms of estimating periodic components and trend, reducing noise and identifying patterns of similar spatiotemporal behavior thanks to the data-adaptive nature of the base functions. Combining MSSA and Gaussian filter can not only obviously remove the north-south striping errors in the GRACE solutions, but also reduce the leakage errors, which can increase the signal-to-noise ratio by comparing with the traditional procedure, i.e. empirical decorrelation method (EDM) followed with the Gaussian filtering. The spatiotemporal characteristics of TWS changes in Xinjiang were validated against the Global Land Dynamics Assimilation System (GLDAS), the Climate Prediction Center (CPC) and in-situ precipitation data. The water storage in Xinjiang shows the relatively large fluctuation from Jan. 2003 to Dec. 2013, with a drop from Jan. 2006 to Dec. 2008 due to the drought event and an obvious rise from Jan. 2009 to Dec. 2010 because of the high precipitation. Spatially, the terrestrial water storage has been increasing in the south Xinjiang, but decreasing in the north Xinjiang. The minimum rate of water storage change is -4.4 mm/yr occurring in the central Tianshan Mountain.

  3. Optimizing Within-Subject Experimental Designs for jICA of Multi-Channel ERP and fMRI.

    Science.gov (United States)

    Mangalathu-Arumana, Jain; Liebenthal, Einat; Beardsley, Scott A

    2018-01-01

    Joint independent component analysis (jICA) can be applied within subject for fusion of multi-channel event-related potentials (ERP) and functional magnetic resonance imaging (fMRI), to measure brain function at high spatiotemporal resolution (Mangalathu-Arumana et al., 2012). However, the impact of experimental design choices on jICA performance has not been systematically studied. Here, the sensitivity of jICA for recovering neural sources in individual data was evaluated as a function of imaging SNR, number of independent representations of the ERP/fMRI data, relationship between instantiations of the joint ERP/fMRI activity (linear, non-linear, uncoupled), and type of sources (varying parametrically and non-parametrically across representations of the data), using computer simulations. Neural sources were simulated with spatiotemporal and noise attributes derived from experimental data. The best performance, maximizing both cross-modal data fusion and the separation of brain sources, occurred with a moderate number of representations of the ERP/fMRI data (10-30), as in a mixed block/event related experimental design. Importantly, the type of relationship between instantiations of the ERP/fMRI activity, whether linear, non-linear or uncoupled, did not in itself impact jICA performance, and was accurately recovered in the common profiles (i.e., mixing coefficients). Thus, jICA provides an unbiased way to characterize the relationship between ERP and fMRI activity across brain regions, in individual data, rendering it potentially useful for characterizing pathological conditions in which neurovascular coupling is adversely affected.

  4. On the estimation of the worst-case implant-induced RF-heating in multi-channel MRI

    Science.gov (United States)

    Córcoles, Juan; Zastrow, Earl; Kuster, Niels

    2017-06-01

    The increasing use of multiple radiofrequency (RF) transmit channels in magnetic resonance imaging (MRI) systems makes it necessary to rigorously assess the risk of RF-induced heating. This risk is especially aggravated with inclusions of medical implants within the body. The worst-case RF-heating scenario is achieved when the local tissue deposition in the at-risk region (generally in the vicinity of the implant electrodes) reaches its maximum value while MRI exposure is compliant with predefined general specific absorption rate (SAR) limits or power requirements. This work first reviews the common approach to estimate the worst-case RF-induced heating in multi-channel MRI environment, based on the maximization of the ratio of two Hermitian forms by solving a generalized eigenvalue problem. It is then shown that the common approach is not rigorous and may lead to an underestimation of the worst-case RF-heating scenario when there is a large number of RF transmit channels and there exist multiple SAR or power constraints to be satisfied. Finally, this work derives a rigorous SAR-based formulation to estimate a preferable worst-case scenario, which is solved by casting a semidefinite programming relaxation of this original non-convex problem, whose solution closely approximates the true worst-case including all SAR constraints. Numerical results for 2, 4, 8, 16, and 32 RF channels in a 3T-MRI volume coil for a patient with a deep-brain stimulator under a head imaging exposure are provided as illustrative examples.

  5. Life-threatening false alarm rejection in ICU: using the rule-based and multi-channel information fusion method.

    Science.gov (United States)

    Liu, Chengyu; Zhao, Lina; Tang, Hong; Li, Qiao; Wei, Shoushui; Li, Jianqing

    2016-08-01

    False alarm (FA) rates as high as 86% have been reported in intensive care unit monitors. High FA rates decrease quality of care by slowing staff response times while increasing patient burdens and stresses. In this study, we proposed a rule-based and multi-channel information fusion method for accurately classifying the true or false alarms for five life-threatening arrhythmias: asystole (ASY), extreme bradycardia (EBR), extreme tachycardia (ETC), ventricular tachycardia (VTA) and ventricular flutter/fibrillation (VFB). The proposed method consisted of five steps: (1) signal pre-processing, (2) feature detection and validation, (3) true/false alarm determination for each channel, (4) 'real-time' true/false alarm determination and (5) 'retrospective' true/false alarm determination (if needed). Up to four signal channels, that is, two electrocardiogram signals, one arterial blood pressure and/or one photoplethysmogram signal were included in the analysis. Two events were set for the method validation: event 1 for 'real-time' and event 2 for 'retrospective' alarm classification. The results showed that 100% true positive ratio (i.e. sensitivity) on the training set were obtained for ASY, EBR, ETC and VFB types, and 94% for VTA type, accompanied by the corresponding true negative ratio (i.e. specificity) results of 93%, 81%, 78%, 85% and 50% respectively, resulting in the score values of 96.50, 90.70, 88.89, 92.31 and 64.90, as well as with a final score of 80.57 for event 1 and 79.12 for event 2. For the test set, the proposed method obtained the score of 88.73 for ASY, 77.78 for EBR, 89.92 for ETC, 67.74 for VFB and 61.04 for VTA types, with the final score of 71.68 for event 1 and 75.91 for event 2.

  6. Investigation of verbal and visual working memory by multi-channel time-resolved functional near-infrared spectroscopy

    Science.gov (United States)

    Contini, D.; Caffini, M.; Re, R.; Zucchelli, L.; Spinelli, L.; Basso Moro, S.; Bisconti, S.; Ferrari, M.; Quaresima, V.; Cutini, S.; Torricelli, A.

    2013-03-01

    Working memory (WM) is fundamental for a number of cognitive processes, such as comprehension, reasoning and learning. WM allows the short-term maintenance and manipulation of the information selected by attentional processes. The goal of this study was to examine by time-resolved fNIRS neural correlates of the verbal and visual WM during forward and backward digit span (DF and DB, respectively) tasks, and symbol span (SS) task. A neural dissociation was hypothesised between the maintenance and manipulation processes. In particular, a dorsolateral/ventrolateral prefrontal cortex (DLPFC/VLPFC) recruitment was expected during the DB task, whilst a lateralised involvement of Brodmann Area (BA) 10 was expected during the execution of the DF task. Thirteen subjects were monitored by a multi-channel, dual-wavelength (690 and 829 nm) time-resolved fNIRS system during 3 minutes long DF and DB tasks and 4 minutes long SS task. The participants' mean memory span was calculated for each task: DF: 6.46+/-1.05 digits; DB: 5.62+/-1.26 digits; SS: 4.69+/-1.32 symbols. No correlation was found between the span level and the heart rate data (measured by pulse oximeter). As expected, DB elicited a broad activated area, in the bilateral VLPFC and the right DLPFC, whereas a more localised activation was observed over the right hemisphere during either DF (BA 10) or SS (BA 10 and 44). The robust involvement of the DLPFC during DB, compared to DF, is compatible with previous findings and with the key role of the central executive subserving in manipulating processes.

  7. A novel LabVIEW-based multi-channel non-invasive abdominal maternal-fetal electrocardiogram signal generator.

    Science.gov (United States)

    Martinek, Radek; Kelnar, Michal; Koudelka, Petr; Vanus, Jan; Bilik, Petr; Janku, Petr; Nazeran, Homer; Zidek, Jan

    2016-02-01

    This paper describes the design, construction, and testing of a multi-channel fetal electrocardiogram (fECG) signal generator based on LabVIEW. Special attention is paid to the fetal heart development in relation to the fetus' anatomy, physiology, and pathology. The non-invasive signal generator enables many parameters to be set, including fetal heart rate (FHR), maternal heart rate (MHR), gestational age (GA), fECG interferences (biological and technical artifacts), as well as other fECG signal characteristics. Furthermore, based on the change in the FHR and in the T wave-to-QRS complex ratio (T/QRS), the generator enables manifestations of hypoxic states (hypoxemia, hypoxia, and asphyxia) to be monitored while complying with clinical recommendations for classifications in cardiotocography (CTG) and fECG ST segment analysis (STAN). The generator can also produce synthetic signals with defined properties for 6 input leads (4 abdominal and 2 thoracic). Such signals are well suited to the testing of new and existing methods of fECG processing and are effective in suppressing maternal ECG while non-invasively monitoring abdominal fECG. They may also contribute to the development of a new diagnostic method, which may be referred to as non-invasive trans-abdominal CTG +  STAN. The functional prototype is based on virtual instrumentation using the LabVIEW developmental environment and its associated data acquisition measurement cards (DAQmx). The generator also makes it possible to create synthetic signals and measure actual fetal and maternal ECGs by means of bioelectrodes.

  8. Optimizing Within-Subject Experimental Designs for jICA of Multi-Channel ERP and fMRI

    Science.gov (United States)

    Mangalathu-Arumana, Jain; Liebenthal, Einat; Beardsley, Scott A.

    2018-01-01

    Joint independent component analysis (jICA) can be applied within subject for fusion of multi-channel event-related potentials (ERP) and functional magnetic resonance imaging (fMRI), to measure brain function at high spatiotemporal resolution (Mangalathu-Arumana et al., 2012). However, the impact of experimental design choices on jICA performance has not been systematically studied. Here, the sensitivity of jICA for recovering neural sources in individual data was evaluated as a function of imaging SNR, number of independent representations of the ERP/fMRI data, relationship between instantiations of the joint ERP/fMRI activity (linear, non-linear, uncoupled), and type of sources (varying parametrically and non-parametrically across representations of the data), using computer simulations. Neural sources were simulated with spatiotemporal and noise attributes derived from experimental data. The best performance, maximizing both cross-modal data fusion and the separation of brain sources, occurred with a moderate number of representations of the ERP/fMRI data (10–30), as in a mixed block/event related experimental design. Importantly, the type of relationship between instantiations of the ERP/fMRI activity, whether linear, non-linear or uncoupled, did not in itself impact jICA performance, and was accurately recovered in the common profiles (i.e., mixing coefficients). Thus, jICA provides an unbiased way to characterize the relationship between ERP and fMRI activity across brain regions, in individual data, rendering it potentially useful for characterizing pathological conditions in which neurovascular coupling is adversely affected. PMID:29410611

  9. Satellite Radio

    Indian Academy of Sciences (India)

    Satellites have been a highly effective platform for multi- form broadcasts. This has led to a revival of the radio era. The satellite radio is a natural choice to bridge the digital gap. It has several novel features like selective addressing and error control. The value-added services from such systems are of particular interest.

  10. Radio-nuclide mixture identification using medium energy resolution detectors

    Science.gov (United States)

    Nelson, Karl Einar

    2013-09-17

    According to one embodiment, a method for identifying radio-nuclides includes receiving spectral data, extracting a feature set from the spectral data comparable to a plurality of templates in a template library, and using a branch and bound method to determine a probable template match based on the feature set and templates in the template library. In another embodiment, a device for identifying unknown radio-nuclides includes a processor, a multi-channel analyzer, and a memory operatively coupled to the processor, the memory having computer readable code stored thereon. The computer readable code is configured, when executed by the processor, to receive spectral data, to extract a feature set from the spectral data comparable to a plurality of templates in a template library, and to use a branch and bound method to determine a probable template match based on the feature set and templates in the template library.

  11. GIFT-Grab: Real-time C++ and Python multi-channel video capture, processing and encoding API

    Directory of Open Access Journals (Sweden)

    Dzhoshkun Ismail Shakir

    2017-10-01

    Full Text Available GIFT-Grab is an open-source API for acquiring, processing and encoding video streams in real time. GIFT-Grab supports video acquisition using various frame-grabber hardware as well as from standard-compliant network streams and video files. The current GIFT-Grab release allows for multi-channel video acquisition and encoding at the maximum frame rate of supported hardware – 60 frames per second (fps. GIFT-Grab builds on well-established highly configurable multimedia libraries including FFmpeg and OpenCV. GIFT-Grab exposes a simplified high-level API, aimed at facilitating integration into client applications with minimal coding effort. The core implementation of GIFT-Grab is in C++11. GIFT-Grab also features a Python API compatible with the widely used scientific computing packages NumPy and SciPy. GIFT-Grab was developed for capturing multiple simultaneous intra-operative video streams from medical imaging devices. Yet due to the ubiquity of video processing in research, GIFT-Grab can be used in many other areas. GIFT-Grab is hosted and managed on the software repository of the Centre for Medical Image Computing (CMIC at University College London, and is also mirrored on GitHub. In addition it is available for installation from the Python Package Index (PyPI via the pip installation tool. Funding statement: This work was supported through an Innovative Engineering for Health award by the Wellcome Trust [WT101957], the Engineering and Physical Sciences Research Council (EPSRC [NS/A000027/1] and a National Institute for Health Research Biomedical Research Centre UCLH/UCL High Impact Initiative. Sébastien Ourselin receives funding from the EPSRC (EP/H046410/1, EP/J020990/1, EP/K005278 and the MRC (MR/J01107X/1. Luis C. García-Peraza-Herrera is supported by the EPSRC-funded UCL Centre for Doctoral Training in Medical Imaging (EP/L016478/1.

  12. Taipei's Use of a Multi-Channel Mass Risk Communication Program to Rapidly Reverse an Epidemic of Highly Communicable Disease

    Science.gov (United States)

    Yen, Muh-Yong; Wu, Tsung-Shu Joseph; Chiu, Allen Wen-Hsiang; Wong, Wing-Wai; Wang, Po-En; Chan, Ta-Chien; King, Chwan-Chuen

    2009-01-01

    Background In September 2007, an outbreak of acute hemorrhagic conjunctivitis (AHC) occurred in Keelung City and spread to Taipei City. In response to the epidemic, a new crisis management program was implemented and tested in Taipei. Methodology and Principal Findings Having noticed that transmission surged on weekends during the Keelung epidemic, Taipei City launched a multi-channel mass risk communications program that included short message service (SMS) messages sent directly to approximately 2.2 million Taipei residents on Friday, October 12th, 2007. The public was told to keep symptomatic students from schools and was provided guidelines for preventing the spread of the disease at home. Epidemiological characteristics of Taipei's outbreak were analyzed from 461 sampled AHC cases. Median time from exposure to onset of the disease was 1 day. This was significantly shorter for cases occurring in family clusters than in class clusters (mean±SD: 2.6±3.2 vs. 4.39±4.82 days, p = 0.03), as well as for cases occurring in larger family clusters as opposed to smaller ones (1.2±1.7 days vs. 3.9±4.0 days, pTaipei's program had a significant impact on patient compliance. Home confinement of symptomatic children increased from 10% to 60% (pTaipei experienced a rapid decrease in AHC cases between the Friday of the SMS announcement and the following Monday, October 15, (0.70% vs. 0.36%). By October 26, AHC cases reduced to 0.01%. The success of this risk communication program in Taipei (as compared to Keelung) is further reflected through rapid improvements in three epidemic indicators: (1) significantly lower crude attack rates (1.95% vs. 14.92%, pTaipei districts that border Keelung (the original domestic epicenter). Conclusions and Significance The timely launch of this systematic, communication-based intervention proved effective at preventing a dangerous spike in AHC and was able to bring this high-risk disease under control. We recommend that public health

  13. Eastern Gondwana breakup and the Lord Howe Rise continental ribbon from multi-channel seismic reflection data

    Science.gov (United States)

    Boston, Brian; Nakamura, Yasuyuki; Kodaira, Shuichi; Miura, Seiichi; Gallais, Flora; Fujie, Gou; Kaiho, Yuka; Hackney, Ron; Yamada, Yasuhiro; Saito, Saneatsu; Shiraishi, Kazuya; Nichol, Scott; Bernardel, George; Mitchell, Cameron

    2017-04-01

    The eastern Australian margin of Gondwana rifted during the Late Cretaceous, forming the Lord Howe Rise continental ribbon. This breakup is still poorly understood with only a few regional studies and suggested formation processes that range from a plume impinging on the lithosphere to upper-plate extension associated with slab rollback. This project uses data collected on a multi-leg geophysical cruise undertaken in 2016 to study the rifting processes at the Lord Howe Rise. This project uses a regional 900 km long east-west oriented profile at 27.2°S with both multi-channel seismic reflection and multibeam bathymetry datasets. We present processed pre-stack depth migrated seismic reflection images and interpretations to show the structure and evolution of this margin from the oceanic Tasman Basin in the west to the extended continental crust of the Lord Howe Rise in the east. The Tasman Basin contains buried basins only on its eastern side. These basins may be related to early transform faulting. The Lord Howe Rise contains both syn-rift and post-rift sedimentary sequences in multiple basins that record the breakup of the margin. Between these two regions are the Dampier Ridge and Middleton Basin. The boundary between the Dampier Ridge and Tasman Basin is a very sharp feature that is unlike any other boundary in the area. This sharp boundary may represent a transform segment. Within the Dampier Ridge, there are multiple rift basins up to 3 km deep that are similar to those on the Lord Howe Rise. In contrast, the Middleton Basin that separates the Dampier Ridge and the Lord Howe Rise is a broad, well-stratified sedimentary basin of up to 3.5 km thick and contains an unconformity that separates deeper sedimentary strata that are conformable with the basement and younger strata that filled the basin post-rifting. These new results indicate a dynamic process and history during the breakup of eastern Gondwana that led to the opening of the Tasman Basin and formation

  14. The structural elements and tectonics of the Lake Van basin (Eastern Anatolia) from multi-channel seismic reflection profiles

    Science.gov (United States)

    Toker, Mustafa; Sengor, A. M. Celal; Demirel Schluter, Filiz; Demirbag, Emin; Cukur, Deniz; Imren, Caner; Niessen, Frank; PaleoVan-Working Group

    2017-05-01

    This study analyzed multi-channel seismic reflection data from Lake Van, Eastern Anatolia, to provide key information on the structural elements, deformational patterns and overall tectonic structure of the Lake Van basin. The seismic data reveal three subbasins (the Tatvan, northern and Ahlat subbasins) separated by structural ridges (the northern and Ahlat ridges). The Tatvan basin is a tilted wedge-block in the west, it is a relatively undeformed and flat-lying deep basin, forming a typical example of strike-slip sedimentation. Seismic sections reveal that the deeper sedimentary sections of the Tatvan basin are locally folded, gently in the south and more intensely further north, suggesting a probable gravitational "wedge-block" instability, oblique to the northern margin. The northern subbasin, bounded by normal oblique faults, forms a basin-margin graben structure that is elongated in a northeast-southwest direction. The east-west trending Ahlat ridge forms a fault-wedged sedimentary ridge and appears to offset by reverse oblique faults forming as a push-up rhomb horst structure. The Ahlat subbasin is a fault-wedged trough fill that is elongated in the west-east direction and appears as a horst-foot graben formed by the normal oblique faults. The northeast-southwest directed northern ridge is a faulted crestal terrace of a sublacustrine basement block. Its step-like morphology, in response to the downfaulting of the Tatvan basin, as well as its backthrusted appearance, indicates the normal oblique nature of the bounding faults. The lacustrine shelf and slope show distinctive stratigraphic features; progradational deltas, submerged fluvial channels, distorted and collapsed beddings and soft sediment deformation structures, characterizing a highly unstable nature of shelf caused by strong oblique faulting and related earthquakes. The faulting caused uplift of the Çarpanak spur zone, together with the northeastern Erek delta, deformation of deltaic structures

  15. Evaluation of atmospheric profiles derived from single- and zero-difference excess phase processing of BeiDou radio occultation data from the FY-3C GNOS mission

    Directory of Open Access Journals (Sweden)

    W. Bai

    2018-02-01

    Full Text Available The Global Navigation Satellite System (GNSS Occultation Sounder (GNOS is one of the new-generation payloads onboard the Chinese FengYun 3 (FY-3 series of operational meteorological satellites for sounding the Earth's neutral atmosphere and ionosphere. The GNOS was designed for acquiring setting and rising radio occultation (RO data by using GNSS signals from both the Chinese BeiDou System (BDS and the US Global Positioning System (GPS. An ultra-stable oscillator with 1 s stability (Allan deviation at the level of 10−12 was installed on the FY-3C GNOS, and thus both zero-difference and single-difference excess phase processing methods should be feasible for FY-3C GNOS observations. In this study we focus on evaluating zero-difference processing of BDS RO data vs. single-difference processing, in order to investigate the zero-difference feasibility for this new instrument, which after its launch in September 2013 started to use BDS signals from five geostationary orbit (GEO satellites, five inclined geosynchronous orbit (IGSO satellites and four medium Earth orbit (MEO satellites. We used a 3-month set of GNOS BDS RO data (October to December 2013 for the evaluation and compared atmospheric bending angle and refractivity profiles, derived from single- and zero-difference excess phase data, against co-located profiles from European Centre for Medium-Range Weather Forecasts (ECMWF analyses. We also compared against co-located refractivity profiles from radiosondes. The statistical evaluation against these reference data shows that the results from single- and zero-difference processing are reasonably consistent in both bias and standard deviation, clearly demonstrating the feasibility of zero differencing for GNOS BDS RO observations. The average bias (and standard deviation of the bending angle and refractivity profiles were found to be about 0.05 to 0.2 % (and 0.7 to 1.6 % over the upper troposphere and lower stratosphere. Zero

  16. Evaluation of atmospheric profiles derived from single- and zero-difference excess phase processing of BeiDou radio occultation data from the FY-3C GNOS mission

    Science.gov (United States)

    Bai, Weihua; Liu, Congliang; Meng, Xiangguang; Sun, Yueqiang; Kirchengast, Gottfried; Du, Qifei; Wang, Xianyi; Yang, Guanglin; Liao, Mi; Yang, Zhongdong; Zhao, Danyang; Xia, Junming; Cai, Yuerong; Liu, Lijun; Wang, Dongwei

    2018-02-01

    The Global Navigation Satellite System (GNSS) Occultation Sounder (GNOS) is one of the new-generation payloads onboard the Chinese FengYun 3 (FY-3) series of operational meteorological satellites for sounding the Earth's neutral atmosphere and ionosphere. The GNOS was designed for acquiring setting and rising radio occultation (RO) data by using GNSS signals from both the Chinese BeiDou System (BDS) and the US Global Positioning System (GPS). An ultra-stable oscillator with 1 s stability (Allan deviation) at the level of 10-12 was installed on the FY-3C GNOS, and thus both zero-difference and single-difference excess phase processing methods should be feasible for FY-3C GNOS observations. In this study we focus on evaluating zero-difference processing of BDS RO data vs. single-difference processing, in order to investigate the zero-difference feasibility for this new instrument, which after its launch in September 2013 started to use BDS signals from five geostationary orbit (GEO) satellites, five inclined geosynchronous orbit (IGSO) satellites and four medium Earth orbit (MEO) satellites. We used a 3-month set of GNOS BDS RO data (October to December 2013) for the evaluation and compared atmospheric bending angle and refractivity profiles, derived from single- and zero-difference excess phase data, against co-located profiles from European Centre for Medium-Range Weather Forecasts (ECMWF) analyses. We also compared against co-located refractivity profiles from radiosondes. The statistical evaluation against these reference data shows that the results from single- and zero-difference processing are reasonably consistent in both bias and standard deviation, clearly demonstrating the feasibility of zero differencing for GNOS BDS RO observations. The average bias (and standard deviation) of the bending angle and refractivity profiles were found to be about 0.05 to 0.2 % (and 0.7 to 1.6 %) over the upper troposphere and lower stratosphere. Zero differencing was found

  17. RadioImmunotherapy for adenoid cystic carcinoma: a single-institution series of combined treatment with cetuximab

    International Nuclear Information System (INIS)

    Jensen, Alexandra D; Krauss, Jürgen; Weichert, Wilko; Debus, Jürgen; Münter, Marc W

    2010-01-01

    Local control in adjuvant/definitive RT of adenoid cystic carcinoma (ACC) is largely dose-dependent. However, some clinical situations do not allow application of tumouricidal doses (i.e. re-irradiation) hence radiation sensitization by exploitation of high endothelial growth factor receptor (EGFR)-expression in ACC seems beneficial. This is a single-institution experience of combined radioimmunotherapy (RIT) with the EGFR-inhibitor cetuximab. Between 2006 and 2010, 9 pts received RIT for advanced/recurrent ACC, 5/9 pts as re-irradiation. Baseline characteristics as well as treatment parameters were retrieved to evaluate efficacy and toxicity of the combination regimen were evaluated. Control rates (local/distant) and overall survival were calculated using Kaplan-Meier estimation. Median dose was 65 Gy, pts received a median of 6 cycles cetuximab. RIT was tolerated well with only one °III mucositis/dysphagia. Overall response/remission rates were high (77,8%); 2-year estimate of local control was 80% hence reaching local control levels comparable to high-dose RT. Progression-free survival (PFS) at 2 years and median overall survival were only 62,5% and 22,2 mo respectively. While local control and treatment response in RIT seems promising, PFS and overall survival are still hampered by distant failure. The potential benefit of RIT with cetuximab warrants exploration in a prospective controlled clinical trial

  18. RadioImmunotherapy for adenoid cystic carcinoma: a single-institution series of combined treatment with cetuximab

    Directory of Open Access Journals (Sweden)

    Weichert Wilko

    2010-11-01

    Full Text Available Abstract Background Local control in adjuvant/definitive RT of adenoid cystic carcinoma (ACC is largely dose-dependent. However, some clinical situations do not allow application of tumouricidal doses (i.e. re-irradiation hence radiation sensitization by exploitation of high endothelial growth factor receptor (EGFR-expression in ACC seems beneficial. This is a single-institution experience of combined radioimmunotherapy (RIT with the EGFR-inhibitor cetuximab. Methods Between 2006 and 2010, 9 pts received RIT for advanced/recurrent ACC, 5/9 pts as re-irradiation. Baseline characteristics as well as treatment parameters were retrieved to evaluate efficacy and toxicity of the combination regimen were evaluated. Control rates (local/distant and overall survival were calculated using Kaplan-Meier estimation. Results Median dose was 65 Gy, pts received a median of 6 cycles cetuximab. RIT was tolerated well with only one °III mucositis/dysphagia. Overall response/remission rates were high (77,8%; 2-year estimate of local control was 80% hence reaching local control levels comparable to high-dose RT. Progression-free survival (PFS at 2 years and median overall survival were only 62,5% and 22,2 mo respectively. Conclusion While local control and treatment response in RIT seems promising, PFS and overall survival are still hampered by distant failure. The potential benefit of RIT with cetuximab warrants exploration in a prospective controlled clinical trial.

  19. Solar Radio

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Scientists monitor the structure of the solar corona, the outer most regions of the Sun's atmosphere, using radio waves (100?s of MHz to 10?s of GHz). Variations in...

  20. Radio astronomy

    International Nuclear Information System (INIS)

    Parijskij, Y.N.; Gossachinskij, I.V.; Zuckerman, B.; Khersonsky, V.K.; Pustilnik, S.; Robinson, B.J.

    1976-01-01

    A critical review of major developments and discoveries in the field of radioastronomy during the period 1973-1975 is presented. The report is presented under the following headings:(1) Continuum radiation from the Galaxy; (2) Neutral hydrogen, 21 cm (galactic and extragalactic) and recombination lines; (3) Radioastronomy investigations of interstellar molecules; (4) Extragalactic radio astronomy and (6) Development in radio astronomy instruments. (B.R.H.)

  1. Unrepeatered Nyquist PDM-16QAM transmission over 364  km using Raman amplification and multi-channel digital back-propagation.

    Science.gov (United States)

    Galdino, Lidia; Tan, Mingming; Lavery, Domaniç; Rosa, Pawel; Maher, Robert; Phillips, Ian D; Ania Castañón, Juan D; Harper, Paul; Killey, Robert I; Thomsen, Benn C; Makovejs, Sergejs; Bayvel, Polina

    2015-07-01

    Transmission of a net 467-Gb/s PDM-16QAM Nyquist-spaced superchannel is reported with an intra-superchannel net spectral efficiency (SE) of 6.6 (b/s)/Hz, over 364-km SMF-28 ULL ultra-low loss optical fiber, enabled by bi-directional second-order Raman amplification and digital nonlinearity compensation. Multi-channel digital back-propagation (MC-DBP) was applied to compensate for nonlinear interference; an improvement of 2 dB in Q(2) factor was achieved when 70-GHz DBP bandwidth was applied, allowing an increase in span length of 37 km.

  2. On the Efficiency of the Multi-Channel Analysis of Surface Wave Method for Shallow and Semi-Deep Loose Soil Layers

    Directory of Open Access Journals (Sweden)

    Kasgin Khaheshi Banab

    2010-01-01

    Full Text Available The multi-channel analysis of surface waves (MASWs method was used to obtain the shear wave velocity variations through near surface (depth 2,300 m/s is very large. The MASW velocity results compared with those of other geophysical approaches, such as seismic reflection/refraction methods and borehole data, where available, mostly confirming the capability of the MASW method to distinguish the high shear wave velocity contrast in the study area. We have found that, of the inversion procedures of MASW data, the random search inversion technique provides better results than the analytical generalized inversion method.

  3. Multi-channel physiological sensing of human emotion: insights into emotion-aware computing using affective protocols, avatars and emotion specifications.

    Science.gov (United States)

    Bamidis, Panagiotis D; Luneski, Andrej; Vivas, Ana; Papadelis, Christos; Maglaveras, Nicos; Pappas, Costas

    2007-01-01

    This paper introduces a methodology for combining multi-channel psycho-physiological recordings of affective paradigms into a framework where the scientific results of such experiments are utilized in the human computer interaction context to model the computer's response based on the emotional context of the user and the situation. An affective protocol is described the results of which are expected to be combined with anthropomorphic avatars that enhance the man-machine interaction. The technological infrastructure of the later component is provided by means of XML specifications of signal descriptions and emotion recognition, as well as avatar behavior generator descriptions.

  4. Radiative parameters for multi-channel visible and near-infrared emission transitions of Sm3+ in heavy-metal-silicate glasses

    Science.gov (United States)

    Yang, Jie; Zhai, Bin; Zhao, Xin; Wang, Zhiqiang; Lin, Hai

    2013-05-01

    Multi-channel visible and near-infrared (NIR) emission transitions originating from 4G5/2 emitting state of Sm3+ in cadmium-aluminum-silicate (CAS) glasses with maximum-phonon-energy of ˜980 cm-1 have been investigated. Based on the measured absorption spectrum, the Judd-Ofelt parameters Ωt (t=2, 4, 6) are derived to be 2.87×10-20, 3.34×10-20 and 1.86×10-20 cm2, respectively. From the evaluated Judd-Ofelt parameters, the radiative parameters such as spontaneous emission probabilities (Arad), branching ratios (β), and radiative lifetime (τrad) are obtained from the 4G5/2 excited level to different lower energy levels. The efficient visible and NIR transition emissions have been observed in the Sm3+ doped CAS glasses, and the maximum stimulated emission cross-sections (σe-max) corresponding to emission peaks are calculated and demonstrated to lay in the same order of magnitude. The quantum efficiency of 4G5/2 level of Sm3+ has been derived to be 60%. Investigations on multi-channel radiative transition emissions originated from 4G5/2 level of Sm3+ in CAS glasses expose its potential applications in tunable laser, medical light source and NIR optoelectronic devices.

  5. An efficient VLSI implementation of on-line recursive ICA processor for real-time multi-channel EEG signal separation.

    Science.gov (United States)

    Shih, Wei-Yeh; Liao, Jui-Chieh; Huang, Kuan-Ju; Fang, Wai-Chi; Cauwenberghs, Gert; Jung, Tzyy-Ping

    2013-01-01

    This paper presents an efficient VLSI implementation of on-line recursive ICA (ORICA) processor for real-time multi-channel EEG signal separation. The proposed design contains a system control unit, a whitening unit, a singular value decomposition unit, a floating matrix multiply unit and, and an ORICA weight training unit. Because the input sample rate of the ORICA processor is 128 Hz, the ORICA processor should produce independent components before the next sample is input in 1/128 s. Under the timing constraints of commutating multi-channel ORICA in real time, the design of the ORICA processor is a mixed architecture, which is designed as different hardware parallelism according to the complexity of processing units. The shared arithmetic processing unit and shared register can reduce hardware complexity and power consumption. The proposed design is implemented used TSMC 90 nm CMOS technology with 8-channel EEG processing in 128 Hz sample rate of raw data and consumes 2.827 mW at 50 MHz clock rate. The performance of the proposed design is also shown to reach 0.0078125 s latency after each EEG sample time, and the average correlation coefficient between the original source signals and extracted ORICA signals for each 1 s frame is 0.9763.

  6. Multi-channel ground-penetrating radar to explore spatial variations in thaw depth and moisture content in the active layer of a permafrost site

    Directory of Open Access Journals (Sweden)

    U. Wollschläger

    2010-08-01

    Full Text Available Multi-channel ground-penetrating radar (GPR was applied at a permafrost site on the Tibetan Plateau to investigate the influence of surface properties and soil texture on the late-summer thaw depth and average soil moisture content of the active layer. Measurements were conducted on an approximately 85 × 60 m2 sized area with surface and soil textural properties that ranged from medium to coarse textured bare soil to finer textured, sparsely vegetated areas covered with fine, wind blown sand, and it included the bed of a gravel road. The survey allowed a clear differentiation of the various units. It showed (i a shallow thaw depth and low average soil moisture content below the sand-covered, vegetated area, (ii an intermediate thaw depth and high average soil moisture content along the gravel road, and (iii an intermediate to deep thaw depth and low to intermediate average soil moisture content in the bare soil terrain. From our measurements, we found hypotheses for the permafrost processes at this site leading to the observed late-summer thaw depth and soil moisture conditions. The study clearly indicates the complicated interactions between surface and subsurface state variables and processes in this environment. Multi-channel GPR is an operational technology to efficiently study such a system at scales varying from a few meters to a few kilometers.

  7. Development of slew-rate-limited time-over-threshold (ToT) ASIC for a multi-channel silicon-based ion detector

    Science.gov (United States)

    Uenomachi, M.; Orita, T.; Shimazoe, K.; Takahashi, H.; Ikeda, H.; Tsujita, K.; Sekiba, D.

    2018-01-01

    High-resolution Elastic Recoil Detection Analysis (HERDA), which consists of a 90o sector magnetic spectrometer and a position-sensitive detector (PSD), is a method of quantitative hydrogen analysis. In order to increase sensitivity, a HERDA system using a multi-channel silicon-based ion detector has been developed. Here, as a parallel and fast readout circuit from a multi-channel silicon-based ion detector, a slew-rate-limited time-over-threshold (ToT) application-specific integrated circuit (ASIC) was designed, and a new slew-rate-limited ToT method is proposed. The designed ASIC has 48 channels and each channel consists of a preamplifier, a slew-rate-limited shaping amplifier, which makes ToT response linear, and a comparator. The measured equivalent noise charges (ENCs) of the preamplifier, the shaper, and the ToT on no detector capacitance were 253±21, 343±46, and 560±56 electrons RMS, respectively. The spectra from a 241Am source measured using a slew-rate-limited ToT ASIC are also reported.

  8. Anti-Sweep Jamming Design and Implementation Using Multi-Channel Harmonic Timing Sequence Detection for Short-Range FMCW Proximity Sensors.

    Science.gov (United States)

    Kong, Zhijie; Li, Ping; Yan, Xiaopeng; Hao, Xinhong

    2017-09-06

    Currently, frequency-modulated continuous-wave (FMCW) proximity sensors are widely used. However, they suffer from a serious sweep jamming problem, which significantly reduces the ranging performance. To improve its anti-jamming capability, this paper analyzed the response mechanism of a proximity sensor with the existence of real target echo signals and sweep jamming, respectively. Then, a multi-channel harmonic timing sequence detection method, using the spectrum components' distribution difference between the real echo signals and sweep jamming, is proposed. Moreover, a novel fast Fourier transform (FFT)-based implementation was employed to extract multi-channel harmonic information. Compared with the traditional band-pass filter (BPF) implementation, this novel realization scheme only computes FFT once, in each transmission cycle, which significantly reduced hardware resource consumption and improved the real-time performance of the proximity sensors. The proposed method was implemented and proved to be feasible through the numerical simulations and prototype experiments. The results showed that the proximity sensor utilizing the proposed method had better anti-sweep jamming capability and ranging performance.

  9. Continuous Estimates of Surface Density and Annual Snow Accumulation with Multi-Channel Snow/Firn Penetrating Radar in the Percolation Zone, Western Greenland Ice Sheet

    Science.gov (United States)

    Meehan, T.; Marshall, H. P.; Bradford, J.; Hawley, R. L.; Osterberg, E. C.; McCarthy, F.; Lewis, G.; Graeter, K.

    2017-12-01

    A priority of ice sheet surface mass balance (SMB) prediction is ascertaining the surface density and annual snow accumulation. These forcing data can be supplied into firn compaction models and used to tune Regional Climate Models (RCM). RCMs do not accurately capture subtle changes in the snow accumulation gradient. Additionally, leading RCMs disagree among each other and with accumulation studies in regions of the Greenland Ice Sheet (GrIS) over large distances and temporal scales. RCMs tend to yield inconsistencies over GrIS because of sparse and outdated validation data in the reanalysis pool. Greenland Traverse for Accumulation and Climate Studies (GreenTrACS) implemented multi-channel 500 MHz Radar in multi-offset configuration throughout two traverse campaigns totaling greater than 3500 km along the western percolation zone of GrIS. The multi-channel radar has the capability of continuously estimating snow depth, average density, and annual snow accumulation, expressed at 95% confidence (+-) 0.15 m, (+-) 17 kgm-3, (+-) 0.04 m w.e. respectively, by examination of the primary reflection return from the previous year's summer surface.

  10. A multi-channel device for high-density target-selective stimulation and long-term monitoring of cells and subcellular features in C. elegans

    Science.gov (United States)

    Coakley, Sean; Mugno, Paula; Hammarlund, Marc; Hilliard, Massimo A.; Lu, Hang

    2014-01-01

    Selective cell ablation can be used to identify neuronal functions in multicellular model organisms such as Caenorhabditis elegans. The optogenetic tool KillerRed facilitates selective ablation by enabling light-activated damage of cell or subcellular components in a temporally and spatially precise manner. However, the use of KillerRed requires stimulating (5 min-1 hr), culturing (~24 hrs) and imaging (often repeatedly) a large number of individual animals. Current manual manipulation methods are limited by their time-consuming, labor-intensive nature, and their usage of anesthetics. To facilitate large-scale selective ablation, culturing, and repetitive imaging, we developed a densely-packed multi-channel device and used it to perform high-throughput neuronal ablation on KillerRed-expressing animals. The ability to load worms in identical locations with high loading efficiency allows us to ablate selected neurons in multiple worms simultaneously. Our device also enables continuous observation of aminals for 24 hrs following KillerRed activation, and allows the animals to be recovered for behavioural assays. We expect this multi-channel device to facilitate a broad range of long-term imaging and selective illumination experiments in neuroscience. PMID:25257026

  11. Radio astronomy

    CERN Document Server

    Alder, Berni

    1975-01-01

    Methods in Computational Physics, Volume 14: Radio Astronomy is devoted to the role of the digital computer both as a control device and as a calculator in addressing problems related to galactic radio noise. This volume contains four chapters and begins with a technical description of the hardware and the special data-handling problems of using radioheliography, with an emphasis on a selection of observational results obtained with the Culgoora radioheliograph and their significance to solar physics and to astrophysics in general. The subsequent chapter examines interstellar dispersion, i

  12. Satellite Radio

    Indian Academy of Sciences (India)

    communications as well as for point-to-multipoint broadcasting. GENERAL I ARTICLE. Radio is perceived to be an individual's possession because of its portability. It can be ... (See Box 1.) Gsa satellites are used for point-to-point communications as ... digital modulations one uses perceptual coding using auditory masking.

  13. Multi-DSP and FPGA based Multi-channel Direct IF/RF Digital receiver for atmospheric radar

    Science.gov (United States)

    Yasodha, Polisetti; Jayaraman, Achuthan; Kamaraj, Pandian; Durga rao, Meka; Thriveni, A.

    2016-07-01

    Modern phased array radars depend highly on digital signal processing (DSP) to extract the echo signal information and to accomplish reliability along with programmability and flexibility. The advent of ASIC technology has made various digital signal processing steps to be realized in one DSP chip, which can be programmed as per the application and can handle high data rates, to be used in the radar receiver to process the received signal. Further, recent days field programmable gate array (FPGA) chips, which can be re-programmed, also present an opportunity to utilize them to process the radar signal. A multi-channel direct IF/RF digital receiver (MCDRx) is developed at NARL, taking the advantage of high speed ADCs and high performance DSP chips/FPGAs, to be used for atmospheric radars working in HF/VHF bands. Multiple channels facilitate the radar t be operated in multi-receiver modes and also to obtain the wind vector with improved time resolution, without switching the antenna beam. MCDRx has six channels, implemented on a custom built digital board, which is realized using six numbers of ADCs for simultaneous processing of the six input signals, Xilinx vertex5 FPGA and Spartan6 FPGA, and two ADSPTS201 DSP chips, each of which performs one phase of processing. MCDRx unit interfaces with the data storage/display computer via two gigabit ethernet (GbE) links. One of the six channels is used for Doppler beam swinging (DBS) mode and the other five channels are used for multi-receiver mode operations, dedicatedly. Each channel has (i) ADC block, to digitize RF/IF signal, (ii) DDC block for digital down conversion of the digitized signal, (iii) decoding block to decode the phase coded signal, and (iv) coherent integration block for integrating the data preserving phase intact. ADC block consists of Analog devices make AD9467 16-bit ADCs, to digitize the input signal at 80 MSPS. The output of ADC is centered around (80 MHz - input frequency). The digitized data is fed

  14. High space velocities of single radio pulsars versus low orbital eccentricities and masses of double neutron stars: Evidence for two different neutron star formation mechanisms

    NARCIS (Netherlands)

    van den Heuvel, E.P.J.

    2010-01-01

    Radio pulsars tend to be high-velocity objects, which implies that the majority of them received a velocity kick of several hundreds of km s(-1) at birth. However, six of the eight known double neutron stars in the galactic disk have quite low orbital eccentricities (0.085-0.27), indicating - taking

  15. Multi-channel EEG signal feature extraction and pattern recognition on horizontal mental imagination task of 1-D cursor movement for brain computer interface.

    Science.gov (United States)

    Serdar Bascil, M; Tesneli, Ahmet Y; Temurtas, Feyzullah

    2015-06-01

    Brain computer interfaces (BCIs), based on multi-channel electroencephalogram (EEG) signal processing convert brain signal activities to machine control commands. It provides new communication way with a computer by extracting electroencephalographic activity. This paper, deals with feature extraction and classification of horizontal mental task pattern on 1-D cursor movement from EEG signals. The hemispherical power changes are computed and compared on alpha & beta frequencies and horizontal cursor control extracted with only mental imagination of cursor movements. In the first stage, features are extracted with the well-known average signal power or power difference (alpha and beta) method. Principal component analysis is used for reducing feature dimensions. All features are classified and the mental task patterns are recognized by three neural network classifiers which learning vector quantization, multilayer neural network and probabilistic neural network due to obtaining acceptable good results and using successfully in pattern recognition via k-fold cross validation technique.

  16. Optimization of a digital lock-in algorithm with a square-wave reference for frequency-divided multi-channel sensor signal detection.

    Science.gov (United States)

    Zhang, Shengzhao; Li, Gang; Lin, Ling; Zhao, Jing

    2016-08-01

    A digital lock-in detection technique is commonly used to measure the amplitude and phase of a selected frequency signal. A technique that uses a square wave as the reference signal has an advantage over the one using a sinusoidal wave due to its easier implementation and higher computational efficiency. However, demodulating multiple-frequency composite signals using square wave reference may result in interference between channels. To avoid interference between channels and reduce the computational complexity, we modify the calculations and determine the optimal parameter settings of the low-pass filter and carrier frequency, as detailed in this paper. The results of our analysis show that when the length of the average filter and carrier frequencies are properly set, the interference between the channels is removed. This optimization produces the digital lock-in detection suitable for measuring multi-channel sensor signals.

  17. The investigation of multi-channel splitters and big-bend waveguides based on 2D sunflower-typed photonic crystals

    Science.gov (United States)

    Liu, Wei; Sun, XiaoHong; Fan, QingBin; Wang, Shuai; Qi, YongLe

    2016-12-01

    Different kinds of multi-channel splitters and big-bend waveguides have been designed and investigated by using sunflower-typed photonic crystals. By comparing the transmission spectra of two kinds of 4-channels beam splitters, we find that "C" type splitter has a relative uniform splitting ratio for different channels in a certain wavelength range. Furthermore three types of waveguides with different bending degrees have been investigated. Except for a little loss in the short wavelength with the increase of the bending degrees, they have almost the same transmission spectra structures. The result can be extended to big-bend waveguides with arbitrary bending degrees. This research is valuable for developing new-typed integrated optical communication devices.

  18. Investigating the astrophysical 22Ne(p, γ23Na and 22Mg(p, γ23Al reactions with a multi-channel scattering formalism

    Directory of Open Access Journals (Sweden)

    Fraser P. R.

    2014-03-01

    Full Text Available The reaction 22Ne(p, γ23Na is key to the NeNa cycle of stellar nucleogenesis, and better understanding of the 22Mg(p, γ23Al reaction is needed to understand the 22Na puzzle in ONe white dwarf novae. We aim to study these reactions using a multi-channel algebraic scattering (MCAS formalism for low-energy nucleon-nucleus scattering, recently expanded to investigate radiative capture. As a first step towards this goal, we here calculate the energy levels of the mass-23 (Ne, Mg, Na, Al nuclei. This is not only because the resonant structure of these nuclei are related to the astrophysical -rates of interest, but also because the interaction parameters determined for describing the energy levels are an integral part of the future calculation of the astrophysical reactions when using the MCAS scheme.

  19. Experimental and theoretical study of hydrodynamic cell lysing of cancer cells in a high-throughput Circular Multi-Channel Microfiltration device

    KAUST Repository

    Ma, W.

    2013-04-01

    Microfiltration is an important microfluidic technique suitable for enrichment and isolation of cells. However, cell lysing could occur due to hydrodynamic damage that may be detrimental for medical diagnostics. Therefore, we conducted a systematic study of hydrodynamic cell lysing in a high-throughput Circular Multi-Channel Microfiltration (CMCM) device integrated with a polycarbonate membrane. HeLa cells (cervical cancer cells) were driven into the CMCM at different flow rates. The viability of the cells in the CMCM was examined by fluorescence microscopy using Acridine Orange (AO)/Ethidium Bromide (EB) as a marker for viable/dead cells. A simple analytical cell viability model was derived and a 3D numerical model was constructed to examine the correlation of between cell lysing and applied shear stress under varying flow rate and Reynolds number. The measured cell viability as a function of the shear stress was consistent with theoretical and numerical predictions when accounting for cell size distribution. © 2013 IEEE.

  20. Biphasic DC measurement approach for enhanced measurement stability and multi-channel sampling of self-sensing multi-functional structural materials doped with carbon-based additives

    Science.gov (United States)

    Downey, Austin; D'Alessandro, Antonella; Ubertini, Filippo; Laflamme, Simon; Geiger, Randall

    2017-06-01

    Investigation of multi-functional carbon-based self-sensing structural materials for structural health monitoring applications is a topic of growing interest. These materials are self-sensing in the sense that they can provide measurable electrical outputs corresponding to physical changes such as strain or induced damage. Nevertheless, the development of an appropriate measurement technique for such materials is yet to be achieved, as many results in the literature suggest that these materials exhibit a drift in their output when measured with direct current (DC) methods. In most of the cases, the electrical output is a resistance and the reported drift is an increase in resistance from the time the measurement starts due to material polarization. Alternating current methods seem more appropriate at eliminating the time drift. However, published results show they are not immune to drift. Moreover, the use of multiple impedance measurement devices (LCR meters) does not allow for the simultaneous multi-channel sampling of multi-sectioned self-sensing materials due to signal crosstalk. The capability to simultaneously monitor multiple sections of self-sensing structural materials is needed to deploy these multi-functional materials for structural health monitoring. Here, a biphasic DC measurement approach with a periodic measure/discharge cycle in the form of a square wave sensing current is used to provide consistent, stable resistance measurements for self-sensing structural materials. DC measurements are made during the measurement region of the square wave while material depolarization is obtained during the discharge region of the periodic signal. The proposed technique is experimentally shown to remove the signal drift in a carbon-based self-sensing cementitious material while providing simultaneous multi-channel measurements of a multi-sectioned self-sensing material. The application of the proposed electrical measurement technique appears promising for real

  1. Space Telecommunications Radio System STRS Cognitive Radio

    Science.gov (United States)

    Briones, Janette C.; Handler, Louis M.

    2013-01-01

    Radios today are evolving from awareness toward cognition. A software defined radio (SDR) provides the most capability for integrating autonomic decision making ability and allows the incremental evolution toward a cognitive radio. This cognitive radio technology will impact NASA space communications in areas such as spectrum utilization, interoperability, network operations, and radio resource management over a wide range of operating conditions. NASAs cognitive radio will build upon the infrastructure being developed by Space Telecommunication Radio System (STRS) SDR technology. This paper explores the feasibility of inserting cognitive capabilities in the NASA STRS architecture and the interfaces between the cognitive engine and the STRS radio. The STRS architecture defines methods that can inform the cognitive engine about the radio environment so that the cognitive engine can learn autonomously from experience, and take appropriate actions to adapt the radio operating characteristics and optimize performance.

  2. Robotic single-port transumbilical total hysterectomy: a pilot study

    OpenAIRE

    Nam, Eun Ji; Kim, Sang Wun; Lee, Maria; Yim, Ga Won; Paek, Ji Heum; Lee, San Hui; Kim, Sunghoon; Kim, Jae Hoon; Kim, Jae Wook; Kim, Young Tae

    2011-01-01

    Objective To evaluate the feasibility of robotic single-port transumbilical total hysterectomy using a home-made surgical glove port system. Methods We retrospectively reviewed the medical records of patients who underwent robotic single-port transumbilical total hysterectomy between January 2010 and July 2010. All surgical procedures were performed through a single 3-4-cm umbilical incision, with a multi-channel system consisting of a wound retractor, a surgical glove, and two 10/12-mm and t...

  3. Tools of radio astronomy

    CERN Document Server

    Wilson, Thomas L; Hüttemeister, Susanne

    2009-01-01

    The recent years have seen breathtaking progress in technology, especially in the receiver and digital technologies relevant for radio astronomy, which has at the same time advanced to shorter wavelengths. This is the updated and completely revised 5th edition of the most used introductory text in radio astronomy. It presents a unified treatment of the entire field from centimeter to sub-millimeter wavelengths. Topics covered include instruments, sensitivity considerations, observational methods and interpretations of the data recorded with both single dishes and interferometers. This text is useful to both students and experienced practicing astronomers. Besides making major updates and additions throughout the book, the authors have re-organized a number of chapters to more clearly separate basic theory from rapidly evolving practical aspects. Further, problem sets have been added at the end of each chapter.

  4. Timing Performance of a MCP Photon Detector Read Out with Multi-Channel Electronics for the Torch System

    Science.gov (United States)

    Castillo García, L.; Fopma, J. M.; Forty, R.; Frei, C.; Gao, R.; Gys, T.; Harnew, N.; Piedigrossi, D.

    2014-06-01

    As part of the R&D phase of the (Time Of internally Reflected Cherenkov light) TORCH project, 8×8 pad micro-channel plate photon detectors are being characterized. Multichannel electronics based on fast amplifier discriminator and time digitization conversion ASICs are used to read out and time the charge signals from single photoelectrons. The MCP performance is investigated with a 20ps pulsed blue laser diode. A time resolution of 90ps is achieved. Timing properties are obtained at modest MCP gain, without time walk correction and no fine calibration of the time-to-digital converter circuit. The reference time is provided by a single-channel MCP photon detector coupled to a Constant Fraction Discriminator. Photoelectron detection efficiencies and back-scattering effect are discussed together with the laser source influence on the timing performance.

  5. Sparse Non-negative Tensor 2D Deconvolution (SNTF2D) for multi channel time-frequency analysis

    DEFF Research Database (Denmark)

    Mørup, Morten; Schmidt, Mikkel N.

    2006-01-01

    We recently introduced two algorithms for sparse non-negative matrix factor 2-D deconvolution (SNMF2D) that are useful for single channel source separation and music transcription. We here extend this approach to the analysis of the log-frequency spectrograms of a multichannel recording. The model....... The algorithms are demonstrated to successfully identify the components of both artificially generated as well as real stereo music....

  6. Radio Jove: Jupiter Radio Astronomy for Citizens

    Science.gov (United States)

    Higgins, Charles; Thieman, J. R.; Flagg, R.; Reyes, F. J.; Sky, J.; Greenman, W.; Brown, J.; Typinski, D.; Ashcraft, T.; Mount, A.

    2014-01-01

    Radio JOVE is a hands-on educational activity that brings the radio sounds of the Sun, Jupiter, the Milky Way Galaxy, and terrestrial radio noise to students, teachers, and the general public. Participants may build a simple radio telescope kit, make scientific observations, and interact with professional radio observatories in real-time over the Internet. Our website (http://radiojove.gsfc.nasa.gov) includes science information, construction manuals, observing guides, and education resources for teachers and students. Radio Jove is continually expanding its participants with over 1800 kits sold to more than 70 countries worldwide. Recently some of our most dedicated observers have upgraded their Radio Jove antennas to semi-professional observatories. We have spectrographs and wide band antennas, some with 8 MHz bandwidth and some with dual polarization capabilities. In an effort to add to the science literature, these observers are coordinating their efforts to pursue some basic questions about Jupiter’s radio emissions (radio source locations, spectral structure, long term changes, etc.). We can compare signal and ionosphere variations using the many Radio Jove observers at different locations. Observers are also working with members of the Long Wavelength Array Station 1 (LWA1) radio telescope to coordinate observations of Jupiter; Radio Jove is planning to make coordinated observations while the Juno Mission is active beginning in 2015. The Radio Jove program is overviewed, its hardware and software are highlighted, recent sample observations are shown, and we demonstrate that we are capable of real citizen science.

  7. Preliminary Interpretations of Multi-Channel Seismic Reflection and Magnetic Data on North Anatolian Fault (NAF) in the Eastern Marmara Region, Turkey

    Science.gov (United States)

    Gözde Okut Toksoy, Nigar; Kurt, Hülya; İşseven, Turgay

    2017-04-01

    The North Anatolian Fault (NAF) is 1600 km long, right lateral strike-slip fault nearly E-W elongated between Karlıova in the east and Saros Gulf in the west. NAF splays into two major strands near the west of Bolu city as Northern and Southern strands. Northern strand passes Sapanca Lake and extends towards west and reaches Marmara Sea through the Gulf of Izmit. The area has high seismicity; 1999 Kocaeli (Mw=7.4) and 1999 Düzce (Mw=7.2) earthquakes caused approximately 150 km long surface rupture between the Gulf of Izmit and Bolu. The rupture has four distinct fault segments as Gölcük, Sapanca, Sakarya, and Karadere from west to east. In this study multi-channel seismic and magnetic data are collected for the first time on the Sapanca Segment to investigate the surficial and deeper geometry of the NAF. Previously, the NAF in the eastern Marmara region is investigated using by paleo-seismological data from trenches on the surface rupture of fault or the geomorphological data (Lettis et al., 2000; Dikbaş and Akyüz, 2010) which have shallower depth targets. Crustal structure and seismic velocities for Central Anatolia and eastern Marmara regions are obtained from deeper targeted refraction data (Gürbüz et al., 1992). However, their velocity models do not have the spatial resolution to determine details of the fault zone structure. Multi-channel seismic and magnetic data in this study were acquired on two N-S directed profiles crossing NAF perpendicularly near Kartepe on the western part of the Sapanca Lake in October 2016. The receiver interval is 5 m, shot interval is 5-10 m, and the total length of the profiles are approximately 1400 m. Buffalo Gun is used as a seismic source for deeper penetration. Conventional seismic reflection processing steps are applied to the data. These are geometry definition, editing, filtering, static correction, velocity analysis and deconvolution, stacking and migration. Echos seismic software package in Geophysical Department

  8. Fundamental studies on initiation and evolution of multi-channel discharges and their application to next generation pulsed power machines.

    Energy Technology Data Exchange (ETDEWEB)

    Schwarz, Jens; Savage, Mark E.; Lucero, Diego Jose; Jaramillo, Deanna M.; Seals, Kelly Gene; Pitts, Todd Alan; Hautzenroeder, Brenna M.; Laine, Mark Richard; Karelitz, David B.; Porter, John L.

    2014-09-01

    Future pulsed power systems may rely on linear transformer driver (LTD) technology. The LTD's will be the building blocks for a driver that can deliver higher current than the Z-Machine. The LTD's would require tens of thousands of low inductance ( %3C 85nH), high voltage (200 kV DC) switches with high reliability and long lifetime ( 10 4 shots). Sandia's Z-Machine employs 36 megavolt class switches that are laser triggered by a single channel discharge. This is feasible for tens of switches but the high inductance and short switch life- time associated with the single channel discharge are undesirable for future machines. Thus the fundamental problem is how to lower inductance and losses while increasing switch life- time and reliability. These goals can be achieved by increasing the number of current-carrying channels. The rail gap switch is ideal for this purpose. Although those switches have been extensively studied during the past decades, each effort has only characterized a particular switch. There is no comprehensive understanding of the underlying physics that would allow predictive capability for arbitrary switch geometry. We have studied rail gap switches via an extensive suite of advanced diagnostics in synergy with theoretical physics and advanced modeling capability. Design and topology of multichannel switches as they relate to discharge dynamics are investigated. This involves electrically and optically triggered rail gaps, as well as discrete multi-site switch concepts.

  9. Stress-related psycho-physiological disorders: randomized single blind placebo controlled naturalistic study of psychometric evaluation using a radio electric asymmetric treatment

    Science.gov (United States)

    2011-01-01

    Background The aim of this study is to investigate the effects of a radio electric asymmetric treatment on psycho-physiological disorders (PPD). PPD are often stress related and are under the unconscious control of the patient and cannot be traced back to any serious physical disease. The brain stimulation treatment protocol used is called Neuro Psycho Physical Optimization (NPPO) with a Radio Electric Asymmetric Conveyer (REAC) device. Methods Psychological stress and PPD were measured for a group of 888 subjects using the Psychological Stress Measure (PSM) test, a self-administered questionnaire. Data were collected immediately before and after the 4-weeks of REAC treatment cycle. Results This study showed a significant reduction in scores measuring subjective perceptions of stress for subjects treated with a cycle of NPPO REAC treatment. At the end-point the number of subjects reporting symptoms of stress-related PPD on the PSM test was significantly reduced, whereas in the placebo group the difference was not significant. Conclusion A cycle of NPPO treatment with REAC was shown to reduce subjective perceptions of stress measured by the PSM test and in particular on PPD. Trial Registration This trial has been registered in the Australian New Zealand Clinical Trials Registry (ANZCTR) with the number: ACTRN12607000463471. PMID:21771304

  10. Hybrid spread spectrum radio system

    Science.gov (United States)

    Smith, Stephen F [London, TN; Dress, William B [Camas, WA

    2010-02-09

    Systems and methods are described for hybrid spread spectrum radio systems. A method, includes receiving a hybrid spread spectrum signal including: fast frequency hopping demodulating and direct sequence demodulating a direct sequence spread spectrum signal, wherein multiple frequency hops occur within a single data-bit time and each bit is represented by chip transmissions at multiple frequencies.

  11. Industrial interference and radio astronomy

    Science.gov (United States)

    Jessner, A.

    2013-07-01

    The interferer - victim scenario is described for the case of industrial interference affecting radio astronomical observatories. The sensitivity of radio astronomical receivers and their interference limits are outlined. EMC above 30 MHz is a serious problem for Radio Astronomy. Interferer (CISPR) and victim (ITU-R RA 769) standards are not harmonised. The emissions from the interferer and their spectral characteristics are not defined sufficiently well by CISPR standards. The required minimum coupling losses (MCL) between an industrial device and radio astronomical antenna depends on device properties but is shown to exceed 140 dB in most cases. Spatial separation of a few km is insufficient on its own, the terrain must shield > 30-40 dB, additional mitigations such as extra shielding or suppression of high frequency emissions may be necessary. A case by case compatibility analysis and tailored EMC measures are required for individual installations. Aggregation of many weak rfi emitters can become serious problem. If deployment densities are high enough, the emission constraints can even exceed those for a single interferer at a short distance from the radio observatory. Compatibility studies must account not only for the single interferer but also for many widely distributed interference sources.

  12. Ultra-wideband microwave photonic frequency downconverter based on carrier-suppressed single-sideband modulation

    Science.gov (United States)

    Wang, Yunxin; Li, Jingnan; Wang, Dayong; Zhou, Tao; Xu, Jiahao; Zhong, Xin; Yang, Dengcai; Rong, Lu

    2018-03-01

    An ultra-wideband microwave photonic frequency downconverter is proposed based on carrier-suppressed single-sideband (CS-SSB) modulation. A radio frequency (RF) signal and a local oscillator (LO) signal are combined to drive a dual-parallel Mach-Zehnder modulator (DPMZM) through the electrical 90°hybrid coupler. To break through the bandwidth limit, an optical bandpass filter (OBPF) is applied simultaneously. Then a photodetector (PD) after OBPF is used to obtain intermediate frequency (IF) signal. Experimental results demonstrate that the proposed frequency downconverter can generate the CS-SSB modulation signal from 2 to 40 GHz in optical spectrum. All the mixing spurs are completely suppressed under the noise floor in electrical spectrum, and the output IF signal possesses high purity with a suppression ratio of the undesired signals (≥40 dB). Furthermore, the multi-octave downconversion can also be implemented to satisfy the bandwidth requirement of multi-channel communication. The proposed frequency downconverter supplies an ultra-wideband and high-purity alternative for the signal processing in microwave photonic applications.

  13. Dedicated multichannel readout ASIC coupled with single crystal diamond for dosimeter application

    International Nuclear Information System (INIS)

    Fabbri, A; Notaristefani, F De; Galasso, M; Cencelli, V Orsolini; Falco, M D; Marinelli, M; Tortora, L; Verona, C; Rinati, G Verona

    2013-01-01

    This paper reports on the tests of a low-noise, multi-channel readout integrated circuit used as a readout electronic front-end for a diamond multi-pixel dosimeter. The system is developed for dose distribution measurement in radiotherapy applications. The first 10-channel prototype chip was designed and fabricated in a 0.18 um CMOS process. Every channel includes a charge integrator with a 10 pF capacitor and a double slope A/D converter. The diamond multi-pixel detector, based on CVD synthetic single crystal diamond Schottky diodes, is made by a 3 × 3 sensor matrix. The overall device has been tested under irradiation with 6 MeV radio therapeutic photon beams at the Policlinico ''Tor Vergata'' (PTV) hospital. Measurements show a 20 fA RMS leakage current from the front-end input stage and a negligible dark current from the diamond detector, a stable temporal response and a good linear behaviour as a function of both dose and dose rate. These characteristics were common to each tested channel.

  14. The EarthScope Array Network Facility: application-driven low-latency web-based tools for accessing high-resolution multi-channel waveform data

    Science.gov (United States)

    Newman, R. L.; Lindquist, K. G.; Clemesha, A.; Vernon, F. L.

    2008-12-01

    Since April 2004 the EarthScope USArray seismic network has grown to over 400 broadband stations that stream multi-channel data in near real-time to the Array Network Facility in San Diego. Providing secure, yet open, access to real-time and archived data for a broad range of audiences is best served by a series of platform agnostic low-latency web-based applications. We present a framework of tools that interface between the world wide web and Boulder Real Time Technologies Antelope Environmental Monitoring System data acquisition and archival software. These tools provide audiences ranging from network operators and geoscience researchers, to funding agencies and the general public, with comprehensive information about the experiment. This ranges from network-wide to station-specific metadata, state-of-health metrics, event detection rates, archival data and dynamic report generation over a stations two year life span. Leveraging open source web-site development frameworks for both the server side (Perl, Python and PHP) and client-side (Flickr, Google Maps/Earth and jQuery) facilitates the development of a robust extensible architecture that can be tailored on a per-user basis, with rapid prototyping and development that adheres to web-standards.

  15. Development and Experimental Validation of a Dry Non-Invasive Multi-Channel Mouse Scalp EEG Sensor through Visual Evoked Potential Recordings

    Directory of Open Access Journals (Sweden)

    Donghyeon Kim

    2017-02-01

    Full Text Available In this paper, we introduce a dry non-invasive multi-channel sensor for measuring brainwaves on the scalps of mice. The research on laboratory animals provide insights to various practical applications involving human beings and other animals such as working animals, pets, and livestock. An experimental framework targeting the laboratory animals has the potential to lead to successful translational research when it closely resembles the environment of real applications. To serve scalp electroencephalography (EEG research environments for the laboratory mice, the dry non-invasive scalp EEG sensor with sixteen electrodes is proposed to measure brainwaves over the entire brain area without any surgical procedures. We validated the proposed sensor system with visual evoked potential (VEP experiments elicited by flash stimulations. The VEP responses obtained from experiments are compared with the existing literature, and analyzed in temporal and spatial perspectives. We further interpret the experimental results using time-frequency distribution (TFD and distance measurements. The developed sensor guarantees stable operations for in vivo experiments in a non-invasive manner without surgical procedures, therefore exhibiting a high potential to strengthen longitudinal experimental studies and reliable translational research exploiting non-invasive paradigms.

  16. Development and Experimental Validation of a Dry Non-Invasive Multi-Channel Mouse Scalp EEG Sensor through Visual Evoked Potential Recordings.

    Science.gov (United States)

    Kim, Donghyeon; Yeon, Chanmi; Kim, Kiseon

    2017-02-09

    In this paper, we introduce a dry non-invasive multi-channel sensor for measuring brainwaves on the scalps of mice. The research on laboratory animals provide insights to various practical applications involving human beings and other animals such as working animals, pets, and livestock. An experimental framework targeting the laboratory animals has the potential to lead to successful translational research when it closely resembles the environment of real applications. To serve scalp electroencephalography (EEG) research environments for the laboratory mice, the dry non-invasive scalp EEG sensor with sixteen electrodes is proposed to measure brainwaves over the entire brain area without any surgical procedures. We validated the proposed sensor system with visual evoked potential (VEP) experiments elicited by flash stimulations. The VEP responses obtained from experiments are compared with the existing literature, and analyzed in temporal and spatial perspectives. We further interpret the experimental results using time-frequency distribution (TFD) and distance measurements. The developed sensor guarantees stable operations for in vivo experiments in a non-invasive manner without surgical procedures, therefore exhibiting a high potential to strengthen longitudinal experimental studies and reliable translational research exploiting non-invasive paradigms.

  17. A multi-channel bioluminescent bacterial biosensor for the on-line detection of metals and toxicity. Part I: design and optimization of bioluminescent bacterial strains

    Energy Technology Data Exchange (ETDEWEB)

    Charrier, Thomas; Durand, Marie-Jose; Jouanneau, Sulivan; Thouand, Gerald [UMR CNRS 6144 GEPEA, CBAC, Nantes University, PRES UNAM, Campus de la Courtaisiere-IUT, La Roche-sur-Yon cedex (France); Dion, Michel [UMR CNRS 6204, Nantes University, PRES UNAM, Biotechnologie, Biocatalyse, Bioregulation, 2, Rue de la Houssiniere, BP 92208, Nantes cedex 3 (France); Pernetti, Mimma; Poncelet, Denis [ONIRIS-ENITIAA, UMR CNRS GEPEA, Rue de la Geraudiere, BP 82225, Nantes cedex 3 (France)

    2011-05-15

    This study describes the construction of inducible bioluminescent strains via genetic engineering along with their characterization and optimization in the detection of heavy metals. Firstly, a preliminary comparative study enabled us to select a suitable carbon substrate from pyruvate, glucose, citrate, diluted Luria-Bertani, and acetate. The latter carbon source provided the best induction ratios for comparison. Results showed that the three constructed inducible strains, Escherichia coli DH1 pBzntlux, pBarslux, and pBcoplux, were usable when conducting a bioassay after a 14-h overnight culture at 30 C. Utilizing these sensors gave a range of 12 detected heavy metals including several cross-detections. Detection limits for each metal were often close to and sometimes lower than the European standards for water pollution. Finally, in order to maintain sensitive bacteria within the future biosensor-measuring cell, the agarose immobilization matrix was compared to polyvinyl alcohol (PVA). Agarose was selected because the detection limits of the bioluminescent strains were not affected, in contrast to PVA. Specific detection and cross-detection ranges determined in this study will form the basis of a multiple metals detection system by the new multi-channel Lumisens3 biosensor. (orig.)

  18. Biodegradation of a commercial mixture of the herbicides atrazine and S-metolachlor in a multi-channel packed biofilm reactor.

    Science.gov (United States)

    Cabrera-Orozco, Alberto; Galíndez-Nájera, Silvia Patricia; Ruiz-Ordaz, Nora; Galíndez-Mayer, Juvencio; Martínez-Jerónimo, Fernando

    2017-11-01

    Atrazine and S-metolachlor are two of the most widely used herbicides for agricultural purposes; consequently, residues of both compounds and their metabolites had been detected in ground and superficial waters. Unlike atrazine, the complete degradation of metolachlor has not been achieved. Hence, the purpose of this research is to study the biodegradation of a commercial mixture of atrazine and S-metolachlor in a prototype of a multi-channel packed-bed-biofilm reactor (MC-PBR) designed with the aim of solving the problems of pressure drop and oxygen transfer, typically found on this type of bioreactors.Because the removal efficiency of the herbicides was increased when Candida tropicalis was added to the original microbial community isolated, the reactor was inoculated with this enriched community. The operational conditions tested in batch and continuous mode did not affect the removal efficiency of atrazine; however, this was not the case for S-metolachlor. The removal rates and efficiencies showed a notable variation along the MC-PBR operation.

  19. 12.5 Gb/s multi-channel broadcasting transmission for free-space optical communication based on the optical frequency comb module.

    Science.gov (United States)

    Tan, Jun; Zhao, Zeping; Wang, Yuehui; Zhang, Zhike; Liu, Jianguo; Zhu, Ninghua

    2018-01-22

    A wide-spectrum, ultra-stable optical frequency comb (OFC) module with 100 GHz frequency intervals based on a quantum dot mode locked (QDML) laser is fabricated by our lab, and a scheme with 12.5 Gb/s multi-channel broadcasting transmission for free-space optical (FSO) communication is proposed based on the OFC module. The output power of the OFC is very stable, with the specially designed circuit and the flatness of the frequency comb over the span of 6 nm, which can be limited to 1.5 dB. Four channel wavelengths are chosen to demonstrate one-to-many channels for FSO communication, like optical wireless broadcast. The outdoor experiment is established to test the bit error rate (BER) and eye diagrams with 12.5 Gb/s on-off keying (OOK). The indoor experiment is used to test the highest traffic rate, which is up to 21 Gb/s for one-hop FSO communication. To the best of our knowledge, this scheme is the first to propose the realization of one-to-many broadcasting transmission for FSO communication based on the OFC module. The advantages of integration, miniaturization, channelization, low power consumption, and unlimited bandwidth of one-to-many broadcasting communication scheme, shows promising results on constructing the future space-air-ground-ocean (SAGO) FSO communication networks.

  20. The design of the layout of faceted multi-channel electro-optical spatial coordinates measuring instrument for point-like bright objects

    Science.gov (United States)

    Repin, Vladislav A.; Gorbunova, Elena V.; Chertov, Aleksandr N.; Korotaev, Valery V.

    2017-06-01

    For many applied problems it is necessary to obtain information about the situation in a wide angular field in order to measure various parameters of objects: their spatial coordinates, instantaneous velocities, and so on. In this case, one interesting bionic approach can be used - a mosaic (or discrete, otherwise, facet) angular field. Such electro-optical system constructively imitates the visual apparatus of insects: many photodetectors like ommatidia (elements of the facet eye structure) are located on a non-planar surface. Such devices can be used in photogrammetry and aerial photography systems (if the space is sufficient), in the transport sector as vehicle orientation organs, as systems for monitoring in unmanned aerial vehicles, in endoscopy for obtaining comprehensive information on the state of various cavities, in intelligent robotic systems. In this manuscript discusses the advantages and disadvantages of multi-channeled optoelectronic systems with a mosaic angular field, presents possible options for their use, and discusses some of the design procedures performed when developing a layout of a coordinate measuring device.

  1. The Use of Continuous Wavelet Transform Based on the Fast Fourier Transform in the Analysis of Multi-channel Electrogastrography Recordings.

    Science.gov (United States)

    Komorowski, Dariusz; Pietraszek, Stanislaw

    2016-01-01

    This paper presents the analysis of multi-channel electrogastrographic (EGG) signals using the continuous wavelet transform based on the fast Fourier transform (CWTFT). The EGG analysis was based on the determination of the several signal parameters such as dominant frequency (DF), dominant power (DP) and index of normogastria (NI). The use of continuous wavelet transform (CWT) allows for better visible localization of the frequency components in the analyzed signals, than commonly used short-time Fourier transform (STFT). Such an analysis is possible by means of a variable width window, which corresponds to the scale time of observation (analysis). Wavelet analysis allows using long time windows when we need more precise low-frequency information, and shorter when we need high frequency information. Since the classic CWT transform requires considerable computing power and time, especially while applying it to the analysis of long signals, the authors used the CWT analysis based on the fast Fourier transform (FFT). The CWT was obtained using properties of the circular convolution to improve the speed of calculation. This method allows to obtain results for relatively long records of EGG in a fairly short time, much faster than using the classical methods based on running spectrum analysis (RSA). In this study authors indicate the possibility of a parametric analysis of EGG signals using continuous wavelet transform which is the completely new solution. The results obtained with the described method are shown in the example of an analysis of four-channel EGG recordings, performed for a non-caloric meal.

  2. Segmentation and profiling consumers in a multi-channel environment using a combination of self-organizing maps (SOM method, and logistic regression

    Directory of Open Access Journals (Sweden)

    Seyed Ali Akbar Afjeh

    2014-05-01

    Full Text Available Market segmentation plays essential role on understanding the behavior of people’s interests in purchasing various products and services through various channels. This paper presents an empirical investigation to shed light on consumer’s purchasing attitude as well as gathering information in multi-channel environment. The proposed study of this paper designed a questionnaire and distributed it among 800 people who were at least 18 years of age and had some experiences on purchasing goods and services on internet, catalog or regular shopping centers. Self-organizing map, SOM, clustering technique was performed based on consumer’s interest in gathering information as well as purchasing products through internet, catalog and shopping centers and determined four segments. There were two types of questions for the proposed study of this paper. The first group considered participants’ personal characteristics such as age, gender, income, etc. The second group of questions was associated with participants’ psychographic characteristics including price consciousness, quality consciousness, time pressure, etc. Using multinominal logistic regression technique, the study determines consumers’ behaviors in each four segments.

  3. Imaging observations of nighttime mid-latitude F-region field-aligned irregularities by an MU radar ultra-multi-channel system

    Directory of Open Access Journals (Sweden)

    S. Saito

    2008-08-01

    Full Text Available Mid-latitude F-region field-aligned irregularities (FAIs were studied by using the middle-and-upper atmosphere (MU radar ultra-multi-channel system with the radar imaging technique. On 12 June 2006, F-region FAI echoes with a period of about one hour were observed intermittently. These echoes were found to be embedded in medium-scale traveling ionospheric disturbances (MSTIDs observed as variations of total electron content (TEC. The echoes drifting away from (toward the radar were observed in the depletion (enhancement phase of the MSTID. The Doppler velocity of the echoes is consistent with the range rates in the the range-time-intensity (RTI maps. Fine scale structures with a spatial scale of 10 km or less were found by the radar imaging analysis. Those structures with positive Doppler velocities (moving away from the radar appeared to drift north- (up- westward, and those with negative Doppler velocities south- (down- eastward approximately along the wavefronts of the MSTID. FAIs with positive Doppler velocities filling TEC depletion regions were observed.

  4. Linear and nonlinear analyses of multi-channel mechanomyographic recordings reveal heterogeneous activation of wrist extensors in presence of delayed onset muscle soreness.

    Science.gov (United States)

    Madeleine, Pascal; Hansen, Ernst A; Samani, Afshin

    2014-12-01

    In this study, we applied multi-channel mechanomyographic (MMG) recordings in combination with linear and nonlinear analyses to investigate muscular and musculotendinous effects of high intensity eccentric exercise. Twelve accelerometers arranged in a 3 × 4 matrix over the dominant elbow muscles were used to detect MMG activity in 12 healthy participants. Delayed onset muscle soreness was induced by repetitive high intensity eccentric contractions of the wrist extensor muscles. Average rectified values (ARV) as well as percentage of recurrence (%REC) and percentage of determinism (%DET) extracted from recurrence quantification analysis were computed from data obtained during static-dynamic contractions performed before exercise, immediately after exercise, and in presence of muscle soreness. A linear mixed model was used for the statistical analysis. The ARV, %REC, and %DET maps revealed heterogeneous MMG activity over the wrist extensor muscles before, immediately after, and in presence of muscle soreness (Psoreness compared with before exercise (Psoreness. Recurrence quantification analysis can be suggested as a tool for detection of MMG changes in presence of muscle soreness. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  5. Multi-Channeled Polymeric Microsystem for Studying the Impact of Surface Topography on Cell Adhesion and Motility

    Directory of Open Access Journals (Sweden)

    Andres Diaz Lantada

    2015-11-01

    Full Text Available This paper presents the complete development and experimental validation of a microsystem designed to systematically assess the impact of surface topography on cell adhesion and dynamics. The microsystem includes two pools for culturing cells and for including chemicals. These pools are connected by several channels that have different microtextures, along which the cells crawl from one well to another. The impact of channel surface topography on cell performance, as well as the influence of other relevant factors, can therefore be assessed. The microsystem stands out for its being able to precisely define the surface topographies from the design stage and also has the advantage of including the different textures under study in a single device. Validation has been carried out by culturing human mesenchymal stem cells (hMSCs on the microsystem pre-treated with a coating of hMSC conditioned medium (CM produced by these cells. The impact of surface topography on cell adhesion, motility, and velocity has been quantified, and the relevance of using a coating of hMSC-CM for these kinds of studies has been analyzed. Main results, current challenges, and future proposals based on the use of the proposed microsystem as an experimental resource for studying cell mechanobiology are also presented.

  6. HAI: A novel airborne multi-channel hygrometer for fast multi-phase H2O quantification: Performance of the HAI instrument during the first flights on the German HALO aircraft

    Science.gov (United States)

    Buchholz, B.; Ebert, V.; Kraemer, M.; Afchine, A.

    2014-12-01

    Common gas phase H2O measurements on fast airborne platforms e.g. using backward facing or "Rosemount"-inlets can lead to a high risk of ice and droplets contamination. In addition, currently no single hygrometer exists that allows a simultaneous, high-speed measurement of all phases (gas, liquid, ice) with the same detection principle. In the rare occasions multi-phase measurements are realized, gas-and condensed-phase observations rely on different methods, instruments and calibration strategies so that precision and accuracy levels are quite difficult to quantify. This is effectively avoided by the novel TDLAS instrument, HAI, Hygrometer for Atmospheric Investigation, which allows a simultaneous, high speed, multi-phase detection without any sensor calibration in a unique "2+2" channel concept. Hai combines two independent wavelength channels, at 1.4 µm and at 2.6 µm, for a wide dynamic range from 1 to 30 000 ppmv, with a simultaneous closed path (extractive) and open path detection. Thus, "Total", i.e. gas-phase plus condensed-phase water is measured by sampling via a forward facing inlet into "closed-path" extractive cells. A selective, sampling-free, high speed gas phase detection is realized via a dual-wavelength "open-path" cell placed outside of the aircraft fuselage. All channels can be sampled with 120 Hz (measurement cycle time Dt=1.6 ms) allowing an unprecedented spatial resolution of 30 cm at 900 km/h. The evaluation of the individual multi-channel raw-data is done post flight, without any channel interdependencies, in calibration-free mode, thus allowing fast, accurate and precise multi-phase water detection in flight. The performance could be shown in more than 200 net flights hours in three scientific flight campaigns (TACTS, ESMVal, ML-CIRRUS) on the new German HALO aircraft. In addition the level of the accuracy of the calibration free evaluation was evaluated at the German national primary water vapor standard.

  7. Radio frequency detection assembly and method for detecting radio frequencies

    Science.gov (United States)

    Cown, Steven H.; Derr, Kurt Warren

    2010-03-16

    A radio frequency detection assembly is described and which includes a radio frequency detector which detects a radio frequency emission produced by a radio frequency emitter from a given location which is remote relative to the radio frequency detector; a location assembly electrically coupled with the radio frequency detector and which is operable to estimate the location of the radio frequency emitter from the radio frequency emission which has been received; and a radio frequency transmitter electrically coupled with the radio frequency detector and the location assembly, and which transmits a radio frequency signal which reports the presence of the radio frequency emitter.

  8. China's first intermediate resolution multi-channel seismic survey in the northern Victoria Land Basin and Terror Rift, Ross Sea, Antarctica

    Science.gov (United States)

    Shen, Zhongyan; Gao, Jinyao; Zhang, Tao; Wang, Wei; Ding, Weifeng; Zhang, Sheng

    2017-04-01

    The West Antarctic Rift System (WARS) represents one of the largest active continental rift systems on Earth and is less well known than other rift systems because it is largely covered by thick ice. The Terror Rift (TR), superimposing on the Victoria Land Basin (VLB) in the western Ross Sea, is identified as the most recent deformational zone of the WARS, thus will provide knowledge of the active deformation process of the WARS. The structure and kinematics of the TR is under debate. Originally, the TR was thought to consist of two parts: the Discovery Graben and the magmatically-intruded Lee Arch. New denser seismic grid in the middle and southern segments of the TR revealed a different structure of the Lee Arch while the northern segment of the TR is not well studied. The glacial history of the VLB/TR region is another attractive issue to the geologists since this area records the behavior information of EAIS and WAIS. In the southern part of the VLB, especially in the McMurdo Sound, the framework of the glacial history is well established after several deep cores which recovery the whole stratigraphic sequences since the onset of the glaciation. However, the glacial history of the northern part of the VLB/TR is less well studied and here we emphasize its importance because the northern part of the VLB/TR is a link between the well-studied southern VLB and the sediment-well-preserved Northern Basin. During the 32nd Chinese National Antarctic Research Expedition, on the board of the RV XueLong, we collected intermediate resolution multi-channel seismic reflection data in the northern VLB/TR. These data will establish new constraints on the timing of deformation, structure and kinematics of the TR, and the history of the EAIS and WAIS.

  9. Surface morphology and surface energy of anode materials influence power outputs in a multi-channel mediatorless bio-photovoltaic (BPV) system.

    Science.gov (United States)

    Bombelli, Paolo; Zarrouati, Marie; Thorne, Rebecca J; Schneider, Kenneth; Rowden, Stephen J L; Ali, Akin; Yunus, Kamran; Cameron, Petra J; Fisher, Adrian C; Ian Wilson, D; Howe, Christopher J; McCormick, Alistair J

    2012-09-21

    Bio-photovoltaic cells (BPVs) are a new photo-bio-electrochemical technology for harnessing solar energy using the photosynthetic activity of autotrophic organisms. Currently power outputs from BPVs are generally low and suffer from low efficiencies. However, a better understanding of the electrochemical interactions between the microbes and conductive materials will be likely to lead to increased power yields. In the current study, the fresh-water, filamentous cyanobacterium Pseudanabaena limnetica (also known as Oscillatoria limnetica) was investigated for exoelectrogenic activity. Biofilms of P. limnetica showed a significant photo response during light-dark cycling in BPVs under mediatorless conditions. A multi-channel BPV device was developed to compare quantitatively the performance of photosynthetic biofilms of this species using a variety of different anodic conductive materials: indium tin oxide-coated polyethylene terephthalate (ITO), stainless steel (SS), glass coated with a conductive polymer (PANI), and carbon paper (CP). Although biofilm growth rates were generally comparable on all materials tested, the amplitude of the photo response and achievable maximum power outputs were significantly different. ITO and SS demonstrated the largest photo responses, whereas CP showed the lowest power outputs under both light and dark conditions. Furthermore, differences in the ratios of light : dark power outputs indicated that the electrochemical interactions between photosynthetic microbes and the anode may differ under light and dark conditions depending on the anodic material used. Comparisons between BPV performances and material characteristics revealed that surface roughness and surface energy, particularly the ratio of non-polar to polar interactions (the CQ ratio), may be more important than available surface area in determining biocompatibility and maximum power outputs in microbial electrochemical systems. Notably, CP was readily outperformed by all

  10. A multi-channel bioluminescent bacterial biosensor for the on-line detection of metals and toxicity. Part II: technical development and proof of concept of the biosensor

    Energy Technology Data Exchange (ETDEWEB)

    Charrier, Thomas; Thouand, Gerald [UMR CNRS 6144 GEPEA, CBAC, Nantes University, PRES UNAM, Campus de la Courtaisiere-IUT, La Roche-sur-Yon cedex (France); Chapeau, Cyrille [Biolumine, Biokar Diagnostic, Rue des Quarante Mines ZAC de Ther-Allonne, Beauvais Cedex (France); Bendria, Loubna; Daniel, Philippe [UMR CNRS 6087 LPEC, Universite du Maine, Av Olivier Messiaen, Le Mans cedex 9 (France); Picart, Pascal [UMR CNRS 6613 IAM-LAUM, Ecole Nationale des Ingenieurs du Mans, Universite du Maine, Le Mans Cedex 9 (France)

    2011-05-15

    This research study deals with the on-line detection of heavy metals and toxicity within the context of environmental pollution monitoring. It describes the construction and the proof of concept of a multi-channel bioluminescent bacterial biosensor in immobilized phase: Lumisens3. This new versatile device, designed for the non-stop analysis of water pollution, enables the insertion of any bioluminescent strains (inducible or constitutive), immobilized in a multi-well removable card. The technical design of Lumisens3 has benefited from both a classical and a robust approach and includes four main parts: (1) a dedicated removable card contains 64 wells, 3 mm in depth, arranged in eight grooves within which bacteria are immobilized, (2) this card is incubated on a Pelletier block with a CCD cooled camera on top for bioluminescence monitoring, (3) a fluidic network feeds the card with the sample to be analyzed and finally (4) a dedicated computer interface, BIOLUX 1.0, controls all the elements of the biosensor, allowing it to operate autonomously. The proof of concept of this biosensor was performed using a set of four bioluminescent bacteria (Escherichia coli DH1 pBzntlux, pBarslux, pBcoplux, and E. coli XL1 pBfiluxCDABE) in the on-line detection of CdCl{sub 2} 0.5 {mu}M and As{sub 2}O{sub 3} 5 {mu}M from an influent. When considering metals individually, the ''fingerprints'' from the biosensor were as expected. However, when metals were mixed together, cross reaction and synergistic effects were detected. This biosensor allowed us to demonstrate the simultaneous on-line cross detection of one or several heavy metals as well as the measurement of the overall toxicity of the sample. (orig.)

  11. The Role of Alternating Bilateral Stimulation in Establishing Positive Cognition in EMDR Therapy: A Multi-Channel Near-Infrared Spectroscopy Study.

    Science.gov (United States)

    Amano, Tamaki; Toichi, Motomi

    2016-01-01

    Eye movement desensitisation and reprocessing (EMDR) is a standard method for treating post-traumatic stress disorder. EMDR treatment consists of desensitisation and resource development and installation (RDI) stages. Both protocols provide a positive alternating bilateral stimulation (BLS). The effect of desensitisation with BLS has been elucidated. However, a role for BLS in RDI remains unknown. Therefore, it is important to measure feelings as subjective data and physiological indicators as objective data to clarify the role of BLS in RDI. RDI was administered to 15 healthy volunteer subjects who experienced pleasant memories. Their oxygenated haemoglobin concentration ([oxy-Hb]), a sensitive index of brain activity, was measured from the prefrontal cortex (PFC) to the temporal cortex using multi-channel near-infrared spectroscopy during recall of a pleasant memory with or without BLS. The BLS used was alternating bilateral tactile stimulation with a vibration machine. The psychological evaluation suggested that RDI was successful. The results showed that, compared with non-BLS conditions, accessibility was increased and subjects were more relaxed under BLS conditions. A significant increase in [oxy-Hb] was detected in the right superior temporal sulcus (STS), and a decrease in the wide bilateral areas of the PFC was observed in response to BLS. The significant BLS-induced activation observed in the right STS, which is closely related to memory representation, suggests that BLS may help the recall of more representative pleasant memories. Furthermore, the significant reduction in the PFC, which is related to emotion regulation, suggests that BLS induces relaxation and comfortable feelings. These results indicate an important neural mechanism of RDI that emotional processing occurred rather than higher cognitive processing during this stage. Considering the neuroscientific evidence to date, BLS in RDI may enhance comfortable feelings about pleasant memories

  12. The Role of Alternating Bilateral Stimulation in Establishing Positive Cognition in EMDR Therapy: A Multi-Channel Near-Infrared Spectroscopy Study.

    Directory of Open Access Journals (Sweden)

    Tamaki Amano

    Full Text Available Eye movement desensitisation and reprocessing (EMDR is a standard method for treating post-traumatic stress disorder. EMDR treatment consists of desensitisation and resource development and installation (RDI stages. Both protocols provide a positive alternating bilateral stimulation (BLS. The effect of desensitisation with BLS has been elucidated. However, a role for BLS in RDI remains unknown. Therefore, it is important to measure feelings as subjective data and physiological indicators as objective data to clarify the role of BLS in RDI. RDI was administered to 15 healthy volunteer subjects who experienced pleasant memories. Their oxygenated haemoglobin concentration ([oxy-Hb], a sensitive index of brain activity, was measured from the prefrontal cortex (PFC to the temporal cortex using multi-channel near-infrared spectroscopy during recall of a pleasant memory with or without BLS. The BLS used was alternating bilateral tactile stimulation with a vibration machine. The psychological evaluation suggested that RDI was successful. The results showed that, compared with non-BLS conditions, accessibility was increased and subjects were more relaxed under BLS conditions. A significant increase in [oxy-Hb] was detected in the right superior temporal sulcus (STS, and a decrease in the wide bilateral areas of the PFC was observed in response to BLS. The significant BLS-induced activation observed in the right STS, which is closely related to memory representation, suggests that BLS may help the recall of more representative pleasant memories. Furthermore, the significant reduction in the PFC, which is related to emotion regulation, suggests that BLS induces relaxation and comfortable feelings. These results indicate an important neural mechanism of RDI that emotional processing occurred rather than higher cognitive processing during this stage. Considering the neuroscientific evidence to date, BLS in RDI may enhance comfortable feelings about pleasant

  13. Multi-channel heat exchanger-reactor using arborescent distributors: A characterization study of fluid distribution, heat exchange performance and exothermic reaction

    International Nuclear Information System (INIS)

    Guo, Xiaofeng; Fan, Yilin; Luo, Lingai

    2014-01-01

    A multi-functional heat exchanger-reactor comprising arborescent (tree-like) distributors and collector, 16 mini-channels in parallel and T-mixers is introduced in this paper. Flow distribution property, pressure drop and heat exchange performance of proposed heat exchanger-reactor are tested and discussed. Firstly, flow distribution uniformity is characterized by CFD simulation and then qualitatively confirmed by visualization experiment. Results show that for total flowrates ranging from 5 mL s −1 to 20 mL s −1 , good distribution uniformity is obtained, with maximum flowrate deviation less than 10%. Then, experiments of heat exchange between hot and cold water are carried out. High values of overall heat transfer coefficient ranging from 2000 to 5000 W m −2  °C −1 are obtained under our working conditions. The volumetric heat exchange capability (UA/V) is found to be around 200 kW m −3  °C −1 , showing a high heat exchange capability with compact design. The roles of end-effect and non-established flow are discussed and are supposed to be responsible for efficient heat transfer. Finally a typical fast exothermic reaction, neutralization between acid and basic solutions, is carried out to test the thermal control capability of the studied heat exchanger-reactor. Results indicate that isothermal condition could be realized by circulating appropriate flowrate of coolant through the heat exchanger. The design of heat exchanger-reactor with arborescent distributor and collector makes possible the application of multi-channel systems. This paper introduces systematically the successful integration of heat exchanger-reactor and its performance evaluation. - Highlights: • A design of mini scale, multichannel heat exchanger-reactor is proposed. • Uniform distribution for parallel channels is obtained with arborescent structure. • High global heat exchange coefficient is found experimentally. • Thermal control capability is verified with an

  14. Enhancement of absorption and resistance of motion utilizing a multi-channel opto-electronic sensor to effectively monitor physiological signs during sport exercise

    Science.gov (United States)

    Alzahrani, Abdullah; Hu, Sijung; Azorin-Peris, Vicente; Barrett, Laura; Esliger, Dale; Hayes, Matthew; Akbare, Shafique; Achart, Jérôme; Kuoch, Sylvain

    2015-03-01

    This study presents an effective engineering approach for human vital signs monitoring as increasingly demanded by personal healthcare. The aim of this work is to study how to capture critical physiological parameters efficiently through a well-constructed electronic system and a robust multi-channel opto-electronic patch sensor (OEPS), together with a wireless communication. A unique design comprising multi-wavelength illumination sources and a rapid response photo sensor with a 3-axis accelerometer enables to recover pulsatile features, compensate motion and increase signal-to-noise ratio. An approved protocol with designated tests was implemented at Loughborough University a UK leader in sport and exercise assessment. The results of sport physiological effects were extracted from the datasets of physical movements, i.e. sitting, standing, waking, running and cycling. t-test, Bland-Altman and correlation analysis were applied to evaluate the performance of the OEPS system against Acti-Graph and Mio-Alpha.There was no difference in heart rate measured using OEPS and both Acti-Graph and Mio-Alpha (both p<0.05). Strong correlations were observed between HR measured from the OEPS and both the Acti-graph and Mio-Alpha (r = 0.96, p<0.001). Bland-Altman analysis for the Acti-Graph and OEPS found the bias 0.85 bpm, the standard deviation 9.20 bpm, and the limits of agreement (LOA) -17.18 bpm to +18.88 bpm for lower and upper limits of agreement respectively, for the Mio-Alpha and OEPS the bias is 1.63 bpm, standard deviation SD8.62 bpm, lower and upper limits of agreement, - 15.27 bpm and +18.58 bpm respectively. The OEPS demonstrates a real time, robust and remote monitoring of cardiovascular function.

  15. Acquisition and preliminary analysis of multi-channel seismic reflection data, acquired during the oceanographic cruises of the TOMO-ETNA experiment

    Directory of Open Access Journals (Sweden)

    Marco Firetto Carlino

    2016-09-01

    Full Text Available The TOMO-ETNA experiment was performed in the framework of the FP7 “MED-SUV” (MEDiterranean SUpersite Volcanoes in order to gain a detailed geological and structural model of the continental and oceanic crust concerning Etna and Aeolian Islands volcanoes (Sicily, Italy, by means of active and passive seismic exploration methodologies. Among all data collected, some 1410 km of marine multi-channel seismic (MCS reflection profiles were acquired in the Ionian and Tyrrhenian Seas during two of the three oceanographic cruises of the TOMO-ETNA experiment, in July and November 2014, with the aim of shading light to deep, intermediate and shallow stratigraphy and crustal structure of the two above mentioned areas. The MCS sections, targeted to deep exploration, were acquired during the oceanographic cruise on board the R/V “Sarmiento de Gamboa”, using an active seismic source of 16 air-guns, for a total volume of 4340 cu. in., and a 3000 m long, 240-channels digital streamer as receiving system. High-resolution seismic profiles were instead collected through the R/V “Aegaeo”, using two smaller air-guns (overall 270 cu. in. volume and a 96 channels, 300 m long digital streamer. This paper provides a detailed description of the acquisition parameters and main processing steps adopted for the MCS data. Some processed lines are shown and preliminarily interpreted, to highlight the overall good quality and the high potential of the MCS sections collected during the TOMO-ETNA experiment.

  16. Call Arrival Rate Prediction and Blocking Probability Estimation for Infrastructure based Mobile Cognitive Radio Personal Area Network

    Directory of Open Access Journals (Sweden)

    Neeta Nathani

    2017-08-01

    Full Text Available The Cognitive Radio usage has been estimated as non-emergency service with low volume traffic. Present work proposes an infrastructure based Cognitive Radio network and probability of success of CR traffic in licensed band. The Cognitive Radio nodes will form cluster. The cluster nodes will communicate on Industrial, Scientific and Medical band using IPv6 over Low-Power Wireless Personal Area Network based protocol from sensor to Gateway Cluster Head. For Cognitive Radio-Media Access Control protocol for Gateway to Cognitive Radio-Base Station communication, it will use vacant channels of licensed band. Standalone secondary users of Cognitive Radio Network shall be considered as a Gateway with one user. The Gateway will handle multi-channel multi radio for communication with Base Station. Cognitive Radio Network operators shall define various traffic data accumulation counters at Base Station for storing signal strength, Carrier-to-Interference and Noise Ratio, etc. parameters and record channel occupied/vacant status. The researches has been done so far using hour as interval is too long for parameters like holding time expressed in minutes and hence channel vacant/occupied status time is only probabilistically calculated. In the present work, an infrastructure based architecture has been proposed which polls channel status each minute in contrary to hourly polling of data. The Gateways of the Cognitive Radio Network shall monitor status of each Primary User periodically inside its working range and shall inform to Cognitive Radio- Base Station for preparation of minutewise database. For simulation, the occupancy data for all primary user channels were pulled in one minute interval from a live mobile network. Hourly traffic data and minutewise holding times has been analyzed to optimize the parameters of Seasonal Auto Regressive Integrated Moving Average prediction model. The blocking probability of an incoming Cognitive Radio call has been

  17. Visualizing multi-channel networks

    DEFF Research Database (Denmark)

    Antemijczuk, Paweł; Magiera, Marta; Jørgensen, Sune Lehmann

    2014-01-01

    In this paper, we propose a visualization to illustrate social interactions, built from multiple distinct channels of communication. The visualization displays a summary of dense personal information in a compact graphical notation. The starting point is an abstract drawing of a spider’s web. Below...

  18. Impact of cognitive radio on radio astronomy

    NARCIS (Netherlands)

    Bentum, Marinus Jan; Boonstra, A.J.; Baan, W.A.

    2010-01-01

    The introduction of new communication techniques requires an increase in the efficiency of spectrum usage. Cognitive radio is one of the new techniques that fosters spectrum efficiency by using unoccupied frequency spectrum for communications. However, cognitive radio will increase the transmission

  19. MARS PATHFINDER RADIO TRACKING

    Data.gov (United States)

    National Aeronautics and Space Administration — The Mars Pathfinder (MPF) Radio Science (RS) data archive contains both raw radio tracking data collected during the surface lifetime of the MPF Lander and results...

  20. Amateur Planetary Radio Data Archived for Science and Education: Radio Jove

    Science.gov (United States)

    Thieman, J.; Cecconi, B.; Sky, J.; Garcia, L. N.; King, T. A.; Higgins, C. A.; Fung, S. F.

    2015-12-01

    The Radio Jove Project is a hands-on educational activity in which students, teachers, and the general public build simple radio telescopes, usually from a kit, to observe single frequency decameter wavelength radio emissions from Jupiter, the Sun, the galaxy, and the Earth usually with simple dipole antennas. Some of the amateur observers have upgraded their receivers to spectrographs and their antennas have become more sophisticated as well. The data records compare favorably to more sophisticated professional radio telescopes such as the Long Wavelength Array (LWA) and the Nancay Decametric Array. Since these data are often carefully calibrated and recorded around the clock in widely scattered locations they represent a valuable database useful not only to amateur radio astronomers but to the professional science community as well. Some interesting phenomena have been noted in the data that are of interest to the professionals familiar with such records. The continuous monitoring of radio emissions from Jupiter could serve as useful "ground truth" data during the coming Juno mission's radio observations of Jupiter. Radio Jove has long maintained an archive for thousands of Radio Jove observations, but the database was intended for use by the Radio Jove participants only. Now, increased scientific interest in the use of these data has resulted in several proposals to translate the data into a science community data format standard and store the data in professional archives. Progress is being made in translating Radio Jove data to the Common Data Format (CDF) and also in generating new observations in that format as well. Metadata describing the Radio Jove data would follow the Space Physics Archive Search and Extract (SPASE) standard. The proposed archive to be used for long term preservation would be the Planetary Data System (PDS). Data sharing would be achieved through the PDS and the Paris Astronomical Data Centre (PADC) and the Virtual Wave Observatory (VWO

  1. La radio digital

    Directory of Open Access Journals (Sweden)

    Carlos Eduardo Cortés S.

    2015-01-01

    Full Text Available La radio digital es un producto de la llamada convergencia digital. Las nuevas tecnologías interconectadas permiten la aparición de nuevos modos de audiencia y la implementación de herramientas versátiles. Habla del problema de los estándares, de la radio satelital, la radio digital terrestre, las radios internacionales, la interactividad.

  2. Ionosphere and Radio Communication

    Indian Academy of Sciences (India)

    ionosphere is used for radio communication and navigation as it reflects long, medium, as well as short radio waves. Since solar radiation is the main cause of the existence of iono- sphere, any variation in the radiations can affect the entire radio communication system. This article attempts to briefly introduce the readers to ...

  3. The multi-channel cochlear implant: multi-disciplinary development of electrical stimulation of the cochlea and the resulting clinical benefit.

    Science.gov (United States)

    Clark, Graeme M

    2015-04-01

    This multi-disciplinary research showed sound could be coded by electrical stimulation of the cochlea and peripheral auditory nervous system. But the temporal coding of frequency as seen in the experimental animal, was inadequate for the important speech frequencies. The data indicated the limitation was due in particular to deterministic firing of neurons and failure to reproduce the normal fine temporo-spatial pattern of neural responses seen with sound. However, the data also showed the need for the place coding of frequency, and this meant multi-electrodes inserted into the cochlea. Nevertheless, before this was evaluated on people we undertook biological safety studies to determine the effects of surgical trauma and electrical stimuli, and how to prevent infection. Then our research demonstrated place of stimulation had timbre and was perceived as vowels. This led to our discovery in 1978 of the formant-extraction speech code that first enabled severely-profoundly deaf people to understand running speech. This result in people who had hearing before becoming severely deaf was an outcome not previously considered possible. In 1985 it was the first multi-channel implant to be approved by the US Food and Drug Administration (FDA). It was also the fore runner of our advanced formant and fixed filter strategies When these codes were used from 1985 for those born deaf or deafened early in life we discovered there was a critical period when brain plasticity would allow speech perception and language to be developed near- normally, and this required in particular the acquisition of place coding. In 1990 this led to the first cochlear implant to be approved by the FDA for use in children. Finally, we achieved binaural hearing in 1989 with bilateral cochlear implants, followed by bimodal speech processing in 1990 with a hearing aid in one ear and implant in the other. The above research has been developed industrially, with for example 250,000 people worldwide receiving

  4. Surface related multiple elimination (SRME) and radon transform forward multiple modeling methods applied to 2D multi-channel seismic profiles from the Chukchi Shelf, Arctic Ocean

    Science.gov (United States)

    Ilhan, I.; Coakley, B. J.

    2013-12-01

    The Chukchi Edges project was designed to establish the relationship between the Chukchi Shelf and Borderland and indirectly test theories of opening for the Canada Basin. During this cruise, ~5300 km of 2D multi-channel reflection seismic profiles and other geophysical data (swath bathymetry, gravity, magnetics, sonobuoy refraction seismic) were collected from the RV Marcus G. Langseth across the transition between the Chukchi Shelf and Chukchi Borderland, where the water depths vary from 30 m to over 3 km. Multiples occur when seismic energy is trapped in a layer and reflected from an acoustic interface more than once. Various kinds of multiples occur during seismic data acquisition. These depend on the ray-path the seismic energy follows through the layers. One of the most common multiples is the surface related multiple, which occurs due to strong acoustic impedance contrast between the air and water. The reflected seismic energy from the water surface is trapped within the water column, thus reflects from the seafloor multiple times. Multiples overprint the primary reflections and complicate data interpretation. Both surface related multiple elimination (SRME) and forward parabolic radon transform multiple modeling methods were necessary to attenuate the multiples. SRME is applied to shot gathers starting with the near offset interpolation, multiple estimation using water depths, and subtracting the model multiple from the shot gathers. This method attenuated surface related multiple energy, however, peg-leg multiples remained in the data. The parabolic radon transform method minimized the effect of these multiples. This method is applied to normal moveout (NMO) corrected common mid-point gathers (CMP). The CMP gathers are fitted or modeled with curves estimated from the reference offset, moveout range, moveout increment parameters. Then, the modeled multiples are subtracted from the data. Preliminary outputs of these two methods show that the surface related

  5. Seafloor surface processes and subsurface paleo-channel unconformities mapped using multi-channel seismic and multi-beam sonar data from the Galicia 3D seismic experiment.

    Science.gov (United States)

    Gibson, J. C.; Shillington, D. J.; Sawyer, D. S.; Jordan, B.; Morgan, J. K.; Ranero, C.; Reston, T. J.

    2015-12-01

    In this study we use geophysical methods, stratigraphic relationships, and coring/drilling leg results to assess possible controls on deep-sea channel formation in order to further constrain paleo-channel (PC) and associated unconformity timing/source processes. A series of cut and fill PC are mapped in 3D multi-channel seismic (MCS) data and compared with multi-beam (MB) sonar bathymetry/backscatter data collected during the Galicia 3D survey with the R/V Marcus G. Langseth (2013). The MCS data were collected using four 6 km streamers spaced at 200 m resulting in 25 m x 25 m common mid-point bins within the ~67 km x 20 km 3D volume. The MB data were collected at an average depth of ~4900 m with a constrained swath width of 4.5 km resulting in 11.25x overlap while enabling 25-m bathymetry and 10-m backscatter grids. The PC lie below the mouth of a submarine canyon at the edge of the Galicia abyssal plain and cut pre/syn-rift sediments; they are bound by a rift block to the north and paleo-levees to the south (maximum height of ~180m). From drilling results, the most recent PC is late Miocene in age. In this study, four PC are traced into the basin as unconformities. Several of the PC/unconformities are tentatively correlated with previously interpreted Pyrenean orogeny/compressional Miocene/Oligocene tectonic events. However, one PC/unconformity within this interval has not been previously interpreted. In order test the hypothesis that the unconformities are the result of a significant change in base level indicated by a low shale/sand (SS) ratio, we use seismic surface attributes to calculate the SS ratio and trace the horizontal extent of the unconformities. Additionally, the MB/MCS seafloor morphology reveals sedimentary waves outboard of the canyon mouth. We use backscatter data to compare the extent of recent processes (e.g., Pleistocene glaciation/de-glaciation) with the unconformities by mapping the surface/shallow subsurface SS ratio (volume scattering).

  6. Classification of four-class motor imagery employing single-channel electroencephalography.

    Directory of Open Access Journals (Sweden)

    Sheng Ge

    Full Text Available With advances in brain-computer interface (BCI research, a portable few- or single-channel BCI system has become necessary. Most recent BCI studies have demonstrated that the common spatial pattern (CSP algorithm is a powerful tool in extracting features for multiple-class motor imagery. However, since the CSP algorithm requires multi-channel information, it is not suitable for a few- or single-channel system. In this study, we applied a short-time Fourier transform to decompose a single-channel electroencephalography signal into the time-frequency domain and construct multi-channel information. Using the reconstructed data, the CSP was combined with a support vector machine to obtain high classification accuracies from channels of both the sensorimotor and forehead areas. These results suggest that motor imagery can be detected with a single channel not only from the traditional sensorimotor area but also from the forehead area.

  7. Ham radio for dummies

    CERN Document Server

    Silver, H Ward

    2013-01-01

    An ideal first step for learning about ham radio Beyond operating wirelessly, today's ham radio operators can transmit data and pictures; use the Internet, laser, and microwave transmitters; and travel to places high and low to make contact. This hands-on beginner guide reflects the operational and technical changes to amateur radio over the past decade and provides you with updated licensing requirements and information, changes in digital communication (such as the Internet, social media, and GPS), and how to use e-mail via radio. Addresses the critical use of ham radio for replacing downe

  8. Evaluation of radio-induced DNA damage and their repair in human lymphocytes by comet assay or single cell gel electrophoresis

    International Nuclear Information System (INIS)

    Nascimento, Patricia A. do; Suzuki, Miriam F.; Okazaki, Kayo

    1997-01-01

    The comet assay, also called single cell gel electrophoresis technique, permits to evaluate quantitatively DNA breakage induced by chemical and physical agents at the level of the single cell. The present paper refers to the construction of dose-response curves to DNA damage and repair studies in human peripheral lymphocytes, utilizing the comet assay for the radiosensitivity analysis. So, the blood samples were obtained from healthy donors (40-50 year old), irradiated in a 60 Co source (GAMMACEL 220) with doses of 0.17, 0.25, 0.57, 1.10, 2.12 and 4.22 Gy (0.59 Gy/min.) and processed 1 and 24 hours after the exposition. Results obtained showed a increase in the total lenght of comet (DNA migration) as a function of radiation dose in samples processed 1 and 24 hours after the treatment. The DNA lesion in irradiated lymphocytes with 4.22 Gy (means value of 101.4 μm) were 3.4 times higher than in the untreated lymphocytes (mean value of 30 μm) instead of 24 hours after the irradiation were 1.5 times higher (mean value of 46.3 μm). This reduction on DNA repair occurred in these cells. It was also possible visualized the presence of subpopulations of the cells with different sensitivity and repair capacity to ionizing radiation in these donors. (author). 8 refs., 3 figs

  9. Radiography of Spanish Radio

    Directory of Open Access Journals (Sweden)

    Dra. Emma Rodero Antón

    2007-01-01

    Full Text Available In its eighty years of existence, radio has been always characterized to adapt to the social, cultural and technological transformations. Thus it has been until this moment. Nevertheless, some years ago, the authors and professionals of this medium have been detecting a stagnation that affects to its structure. At a time in continuous technological evolution, radio demands a deep transformation. For that reason, from the conviction of which the future radio, public and commercial, will necessarily have to renew itself, in this paper we establish ten problems and their possible solutions to the radio crisis in order to draw an x-ray of radio in Spain. Radio has future, but it is necessary to work actively by it. That the radio continues being part of sound of our life, it will depend on the work of all: companies, advertisers, professionals, students, investigators and listeners.

  10. Survey Layanan Publik Pemantauan Frekuensi Radio untuk Radio Amatir Dan Radio Antar Penduduk Indonesia

    OpenAIRE

    Azwar Aziz

    2014-01-01

    Berlatar belakang fenomena penggunaan amatir radio dan komunikasi radio antar penduduk yang berkaitan dengan faktor layanan publik dari monitor frekuensi radio, dimana peneliti memfokuskan pada permasalahan kondisi pelayanan publik yang diberikan oleh pemerintah tentang penggunaan radio non komersial yang digunakan oleh perorangan. Penelitian ini memperlihatkan penggiat amatir radio dan komunikasi radio antar penduduk bervariasi, mulai dari yang tidak mempunyai izin sampai pada yang memiliki ...

  11. Single channel atmospheric pressure transporting plasma and plasma stream demultiplexing: physical characterization and application to E. coli bacteria inactivation

    International Nuclear Information System (INIS)

    Valinataj Omran, A; Arefi-Khonsari, F; Sohbatzadeh, F; Siadati, S N; Hosseinzadeh Colagar, A; Akishev, Y

    2017-01-01

    In this article, we developed transporting plasma sources that operate at atmospheric pressure. The effect of electrode configuration on plasma transporting was investigated. In order to increase the transporting plasma cross-section, we converted a plasma stream into four plasma channels by a cylindrical housing. Electron excitation and rotational temperatures were estimated using optical emission spectroscopy. Furthermore, the electrical and temporal characteristics of the plasma, discharge power and charge deposition on the target were investigated. The propagation characteristics of single and multi-channel transporting plasma were compared with the same cross-sectional area. Two configurations for multi-channels were designed for this purpose. Escherichia coli bacteria were exposed to the single and multi-channel transporting discharge for different time durations. After exposure, the results indicated that the inactivation zones were significantly increased by a multi-channel transporting plasma. Finally, E. coli inactivation by those plasma apparatuses was compared with that of several standard antimicrobial test discs such as Gentamicin, Tetracycline, Amoxicillin and Cefixime. (paper)

  12. Repositioning and stabilization of the radial styloid process in comminuted fractures of the distal radius using a single approach: the radio-volar double plating technique

    Directory of Open Access Journals (Sweden)

    Jacobi Matthias

    2010-08-01

    Full Text Available Abstract Background A possible difficulty in intra-articular fracture of the distal radius is the displacement tendency of the radial styloid process due to the tension of the brachioradialis tendon. Methods Ten patients treated within one year for complex distal radius fractures by double-plating technique with a radial buttress plate and volar locking plate, through a single volar approach, were followed prospectively during 24 months. Outcome measures included radiographic follow-up, range of motion, grip strength and score follow-up (VAS, Gartland-Werley score and patient-rated wrist evaluation. Results Ten patients with intraarticular distal radius fractures with dislocation of the radial styloid process were treated with this technique. This resulted after 24 months in good clinical outcome (mean visual analog scale 0.9; almost symmetric range of motion; mean Gartland-Werley score 2 ± 3; mean patient-rated wrist evaluation 3.2 ± 2.4. Radiologic evaluation according to the Dresdner Score revealed anatomic reduction without secondary dislocation during the follow-up and uneventful consolidation. Conclusions The described technique strongly facilitates anatomic reduction and stable fixation of intra-articular distal radius fractures with dislocation of the radial styloid process and leads to satisfactory clinical and radiographic outcome.

  13. Radio-photothermal therapy mediated by a single compartment nanoplatform depletes tumor initiating cells and reduces lung metastasis in the orthotopic 4T1 breast tumor model

    Science.gov (United States)

    Zhou, Min; Zhao, Jun; Tian, Mei; Song, Shaoli; Zhang, Rui; Gupta, Sanjay; Tan, Dongfeng; Shen, Haifa; Ferrari, Mauro; Li, Chun

    2015-11-01

    Tumor Initiating Cells (TICs) are resistant to radiotherapy and chemotherapy, and are believed to be responsible for tumor recurrence and metastasis. Combination therapies can overcome the limitation of conventional cancer treatments, and have demonstrated promising application in the clinic. Here, we show that dual modality radiotherapy (RT) and photothermal therapy (PTT) mediated by a single compartment nanosystem copper-64-labeled copper sulfide nanoparticles ([64Cu]CuS NPs) could suppress breast tumor metastasis through eradication of TICs. Positron electron tomography (PET) imaging and biodistribution studies showed that more than 90% of [64Cu]CuS NPs was retained in subcutaneously grown BT474 breast tumor 24 h after intratumoral (i.t.) injection, indicating the NPs are suitable for the combination therapy. Combined RT/PTT therapy resulted in significant tumor growth delay in the subcutaneous BT474 breast cancer model. Moreover, RT/PTT treatment significantly prolonged the survival of mice bearing orthotopic 4T1 breast tumors compared to no treatment, RT alone, or PTT alone. The RT/PTT combination therapy significantly reduced the number of tumor nodules in the lung and the formation of tumor mammospheres from treated 4T1 tumors. No obvious side effects of the CuS NPs were noted in the treated mice in a pilot toxicity study. Taken together, our data support the feasibility of a therapeutic approach for the suppression of tumor metastasis through localized RT/PTT therapy.Tumor Initiating Cells (TICs) are resistant to radiotherapy and chemotherapy, and are believed to be responsible for tumor recurrence and metastasis. Combination therapies can overcome the limitation of conventional cancer treatments, and have demonstrated promising application in the clinic. Here, we show that dual modality radiotherapy (RT) and photothermal therapy (PTT) mediated by a single compartment nanosystem copper-64-labeled copper sulfide nanoparticles ([64Cu]CuS NPs) could suppress

  14. The radio structure of radio-quiet quasars

    NARCIS (Netherlands)

    Leipski, C.; Falcke, H.D.E.; Bennert, N.; Hüttemeister, S.

    2006-01-01

    Aims.We investigate the radio emitting structures of radio-quiet active galactic nuclei with an emphasis on radio-quiet quasars to study their connection to Seyfert galaxies.
    Methods: .We present and analyse high-sensitivity VLA radio continuum images of 14 radio-quiet quasars and six Seyfert

  15. Senior radio listeners

    DEFF Research Database (Denmark)

    Blaakilde, Anne Leonora

    Radiobroadcasting and the hardware materialization of radio have during the 20th century changed significantly, which means that senior radio listeners have travelled along with this evolution from large, impressive radio furnitures to DAB and small, wireless, mobile devices, and from grave...... and solemn radio voices to lightharted, laughing and chatting speakers. Senior radio listerners have experienced the development and refinements of technique, content and genres. It is now expected of all media users that they are capable of crossing media, combining, juggling and jumping between various...... media platforms, not the least when listening to radio. The elder generation is no exception from this. Recently, for instance, the Danish public broadcast DR has carried out an exodus of programmes targeted for the senior segment. These programmes are removed from regular FM and sent to DAB receivers...

  16. Senior radio listeners

    DEFF Research Database (Denmark)

    Blaakilde, Anne Leonora

    Radiobroadcasting and the hardware materialization of radio have during the 20th century changed significantly, which means that senior radio listeners have travelled along with this evolution from large, impressive radio furnitures to DAB and small, wireless, mobile devices, and from grave...... media platforms, not the least when listening to radio. The elder generation is no exception from this. Recently, for instance, the Danish public broadcast DR has carried out an exodus of programmes targeted for the senior segment. These programmes are removed from regular FM and sent to DAB receivers...

  17. Radio Surveys: an Overview

    NARCIS (Netherlands)

    Morganti, Raffaella

    Radio astronomy has provided important surveys that have made possible key (and sometimes serendipitous) discoveries. I will briefly mention some of the past continuum and line (HI) radio surveys as well as new, on-going surveys and surveys planned for the near future. This new generation of large

  18. Ionosphere and Radio Communication

    Indian Academy of Sciences (India)

    The upperionosphere is used for radio communication and navigationas it reflects long, medium, as well as short radio waves. Sincesolar radiation is the main cause of the existence of ionosphere,any variation in the radiations can affect the entireradio communication system. This article attempts to brieflyintroduce the ...

  19. Writing for Radio.

    Science.gov (United States)

    Tupper, Marianna S.

    1995-01-01

    Describes a 24-hour commercial radio station simulation class project for eighth-grade language arts. Students wrote their own scripts, chose music and were disc jockeys on their own music and talk shows, and prepared news and traffic reports. Guest speakers from actual commercial radio came in to discuss issues such as advertising, censorship,…

  20. Software defined radio receivers exploiting noise cancelling: A tutorial review

    NARCIS (Netherlands)

    Klumperink, Eric A.M.; Nauta, Bram

    2014-01-01

    Traditional radio receivers were narrowband and dedicated to a single frequency band exploiting LC tanks, whereas software defined radios target a flexibly programmable frequency. The broadband noise cancelling circuit technique has proven useful to achieve this target, as it breaks the traditional

  1. Workshop on Radio Recombination Lines

    CERN Document Server

    1980-01-01

    Since their first detection 15 years ago, radio recombination lines from several elements have been observed in a wide variety of objects including HII regions, planetary nebulae, molecular clouds, the diffuse interstellar medium, and recently, other galaxies. The observations span almost the entire range from 0.1 to 100 GHz, and employ both single­ djsh and aperture synthesis techniques. The theory of radio recombination lines has also advanced strongly, to the point where it is perhaps one of the best-understood in astro­ physics. In a parallel development, it has become possible over the last decade to study these same highly-excited atoms in the laboratory; this work provides further confirmation of the theoretical framework. However there has been continuing controversy over the astrophysical interpre­ tation of radio recombination line observations, especially regarding the role of stimulated emission. A workshop was held in Ottawa on 24-25 August, 1979, bringing together many of the active scientist...

  2. Single Platform Geolocation of Radio Frequency Emitters

    Science.gov (United States)

    2015-03-26

    that [9] Rxx = QDQH = [ Qs Qw ]  Ds 00 σ2wI  [ Qs Qw ]H (2.26) where Qs consists of the K eigenvectors which span the signal...When K < M the matrix ARssAH is singular with rank K and the relation [19] det ( ARssAH ) = det ( Rxx − σ2wI ) = 0 (2.27) indicates that σ2w is an...There are K linearly independent eigenvectors qs with corresponding eigenvalues λs of the matrix ARssAH which are also eigenvectors of Rxx as shown by [9

  3. Radio Band Observations of Blazar Variability

    Indian Academy of Sciences (India)

    2016-01-27

    Jan 27, 2016 ... The properties of blazar variability in the radio band are studied using the unique combination of temporal resolution from single dish monitoring and spatial resolution from VLBA imaging. Such measurements now available in all four Stokes parameters, together with theoretical simulations, identify the ...

  4. Unlocking radio broadcasts

    DEFF Research Database (Denmark)

    Skov, Mette; Lykke, Marianne

    2012-01-01

    This poster reports the preliminary results of a user study uncovering the information seeking behaviour of humanities scholars dedicated to radio research. The study is part of an interdisciplinary research project on radio culture and auditory resources. The purpose of the study is to inform...... the design of information architecture and interaction design of a research infrastructure that will enable future radio and audio based research. Results from a questionnaire survey on humanities scholars‟ research interest and information needs, preferred access points, and indexing levels are reported...

  5. Radio broadcasting via satellite

    Science.gov (United States)

    Helm, Neil R.; Pritchard, Wilbur L.

    1990-10-01

    Market areas offering potential for future narrowband broadcast satellites are examined, including international public diplomacy, government- and advertising-supported, and business-application usages. Technical issues such as frequency allocation, spacecraft types, transmission parameters, and radio receiver characteristics are outlined. Service and system requirements, advertising revenue, and business communications services are among the economic issues discussed. The institutional framework required to provide an operational radio broadcast service is studied, and new initiatives in direct broadcast audio radio systems, encompassing studies, tests, in-orbit demonstrations of, and proposals for national and international commercial broadcast services are considered.

  6. Shoestring Budget Radio Astronomy

    Science.gov (United States)

    Hoot, John E.

    2017-06-01

    The commercial exploitation of microwave frequencies for cellular, WiFi, Bluetooth, HDTV, and satellite digital media transmission has brought down the cost of the components required to build an effective radio telescope to the point where, for the cost of a good eyepiece, you can construct and operate a radio telescope. This paper sets forth a family of designs for 1421 MHz telescopes. It also proposes a method by which operators of such instruments can aggregate and archive data via the Internet. With 90 or so instruments it will be possible to survey the entire radio sky for transients with a 24 hour cadence.

  7. Optimization of time-correlated single photon counting spectrometer

    International Nuclear Information System (INIS)

    Zhang Xiufeng; Du Haiying; Sun Jinsheng

    2011-01-01

    The paper proposes a performance improving scheme for the conventional time-correlated single photon counting spectrometer and develops a high speed data acquisition card based on PCI bus and FPGA technologies. The card is used to replace the multi-channel analyzer to improve the capability and decrease the volume of the spectrometer. The process of operation is introduced along with the integration of the spectrometer system. Many standard samples are measured. The experimental results show that the sensitivity of the spectrometer is single photon counting, and the time resolution of fluorescence lifetime measurement can be picosecond level. The instrument could measure the time-resolved spectroscopy. (authors)

  8. Planck intermediate results: XLV. Radio spectra of northern extragalactic radio sources

    DEFF Research Database (Denmark)

    Ade, P. A R; Aghanim, N.; Aller, H. D.

    2016-01-01

    ground-based radio observations between 1.1 and 37 GHz. The single-survey Planck data confirm that the flattest high-frequency radio spectral indices are close to zero, indicating that the original accelerated electron energy spectrum is much harder than commonly thought, with power-law index around 1......Continuum spectra covering centimetre to submillimetre wavelengths are presented for a northern sample of 104 extragalactic radio sources, mainly active galactic nuclei, based on four-epoch Planck data. The nine Planck frequencies, from 30 to 857 GHz, are complemented by a set of simultaneous.......5 instead of the canonical 2.5. The radio spectra peak at high frequencies and exhibit a variety of shapes. For a small set of low-z sources, we find a spectral upturn at high frequencies, indicating the presence of intrinsic cold dust. Variability can generally be approximated by achromatic variations...

  9. Music, radio and mediatization

    DEFF Research Database (Denmark)

    Michelsen, Morten; Krogh, Mads

    2016-01-01

    Mediatization has become a key concept for understanding the relations between media and other cultural and social fields. Contributing to the discussions related to the concept of mediatization, this article discusses how practices of radio and music(al life) influence each other. We follow Deacon......’s and Stanyer’s advice to supplement the concept of mediatization with ‘a series of additional concepts at lower levels of abstraction’ and suggest, in this respect, the notion of heterogeneous milieus of music–radio. Hereby, we turn away from the all-encompassing perspectives related to the concept...... of mediatization where media as such seem to be ascribed agency. Instead, we consider historical accounts of music–radio in order to address the complex nonlinearity of concrete processes of mediatization as they take place in the multiple meetings between a decentred notion of radio and musical life....

  10. Social cognitive radio networks

    CERN Document Server

    Chen, Xu

    2015-01-01

    This brief presents research results on social cognitive radio networks, a transformational and innovative networking paradigm that promotes the nexus between social interactions and cognitive radio networks. Along with a review of the research literature, the text examines the key motivation and challenges of social cognitive radio network design. Three socially inspired distributed spectrum sharing mechanisms are introduced: adaptive channel recommendation mechanism, imitation-based social spectrum sharing mechanism, and evolutionarily stable spectrum access mechanism. The brief concludes with a discussion of future research directions which ascertains that exploiting social interactions for distributed spectrum sharing will advance the state-of-the-art of cognitive radio network design, spur a new line of thinking for future wireless networks, and enable novel wireless service and applications.

  11. Eratosthenes via Ham Radio

    Science.gov (United States)

    Koser, John F.

    1975-01-01

    A secondary geology class used Eratosthenes' method for measuring the circumference of the earth by comparing their measurements of the shadow of a vertical rod to the measurements made by another person contacted by ham radio. (MLH)

  12. Wireless radio a history

    CERN Document Server

    Coe, Lewis

    2006-01-01

    ""Informative...recommended""--Choice; ""interesting...a good read...well worth reading""--Contact Magazine. This history first looks at Marconi's wireless communications system and then explores its many applications, including marine radio, cellular telephones, police and military uses, television and radar. Radio collecting is also discussed, and brief biographies are provided for the major figures in the development and use of the wireless.

  13. ¿Radios ciudadanas?

    OpenAIRE

    López Vigil, José Ignacio

    1998-01-01

    Educativas, sindicales, populares, comunitarias, libres, rebeldes, participativas, alternativas, alterativas, han sido las denominaciones de la radio cuando su proyecto está al servicio de la gente. Palabras apropiadas y nobles -dice elautor-pero devaluadas, a las que ahora se agrega la radio ciudadana, para relievarla como ejercicio depoder y espacio de verdadera participación de la genteenla vida de su nación.

  14. Architectures/Algorithms/Tools for Ultra-Low Power, Compact EVA Digital Radio, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The EVA digital radio imposes tight constraints on power consumption, latency, throughput, form factor, reconfigurability, single event upset and fault tolerance,...

  15. Classics in radio astronomy

    CERN Document Server

    Sullivan, Woodruff Turner

    1982-01-01

    Radio techniques were the nrst to lead astronomy away from the quiescent and limited Universe revealed by traditional observations at optical wave­ lengths. In the earliest days of radio astronomy, a handful of radio physicists and engineers made one startling discovery after another as they opened up the radio sky. With this collection of classic papers and the extensive intro­ ductory material, the reader can experience these exciting discoveries, as well as understand the developing techniques and follow the motivations which prompted the various lines of inquiry. For instance he or she will follow in detail the several attempts to detect radio waves from the sun at the turn of the century; the unravelling by Jansky of a "steady hiss type static"; the incredible story of Reber who built a 9 meter dish in his backyard in 1937 and then mapped the Milky Way; the vital discoveries by Hey and colleagues of radio bursts from the Sun and of a discrete source in the constellation of Cygnus; the development of re...

  16. Astrometry of southern radio sources

    Science.gov (United States)

    White, Graeme L.; Jauncey, David L.; Harvey, Bruce R.; Savage, Ann; Gulkis, Samuel; Preston, Robert A.

    1991-01-01

    An overview is presented of a number of astrometry and astrophysics programs based on radio sources from the Parkes 2.7 GHz catalogs. The programs cover the optical identification and spectroscopy of flat-spectrum Parkes sources and the determination of their milliarcsecond radio structures and positions. Work is also in progress to tie together the radio and Hipparcos positional reference frames. A parallel program of radio and optical astrometry of southern radio stars is also under way.

  17. Radio continuum observations of NML Cygni

    International Nuclear Information System (INIS)

    Gregory, P.C.; Seaquist, E.R.

    1976-01-01

    An attempt to detect thermal radio emission from a compact circumstellar cloud about the infrared star NML Cyg has been carried out at three frequencies, 2.7, 8.1, and 10.5 GHz. Although positive results were obtained with single-dish observations at 10.5 GHz, the radio emission is not from a circumstellar cloud about NML Cyg. Instead it is postulated that the emission is from an H ii region with an angular extent of approx.2'. The red print of the Sky Survey shows a faint nebulosity of comparable angular size overlapping the star's position, lending support to this interpretation. The interferometer observations at 2.7 and 8.1 GHz provide an upper limit on the radio emission from any compact circumstellar cloud about NML Cyg of 2.8 mJy, which is well below the flux density expected for the absorbing cloud postulated by Davies et al. (1972)

  18. The radio spectral energy distribution of infrared-faint radio sources

    Science.gov (United States)

    Herzog, A.; Norris, R. P.; Middelberg, E.; Seymour, N.; Spitler, L. R.; Emonts, B. H. C.; Franzen, T. M. O.; Hunstead, R.; Intema, H. T.; Marvil, J.; Parker, Q. A.; Sirothia, S. K.; Hurley-Walker, N.; Bell, M.; Bernardi, G.; Bowman, J. D.; Briggs, F.; Cappallo, R. J.; Callingham, J. R.; Deshpande, A. A.; Dwarakanath, K. S.; For, B.-Q.; Greenhill, L. J.; Hancock, P.; Hazelton, B. J.; Hindson, L.; Johnston-Hollitt, M.; Kapińska, A. D.; Kaplan, D. L.; Lenc, E.; Lonsdale, C. J.; McKinley, B.; McWhirter, S. R.; Mitchell, D. A.; Morales, M. F.; Morgan, E.; Morgan, J.; Oberoi, D.; Offringa, A.; Ord, S. M.; Prabu, T.; Procopio, P.; Udaya Shankar, N.; Srivani, K. S.; Staveley-Smith, L.; Subrahmanyan, R.; Tingay, S. J.; Wayth, R. B.; Webster, R. L.; Williams, A.; Williams, C. L.; Wu, C.; Zheng, Q.; Bannister, K. W.; Chippendale, A. P.; Harvey-Smith, L.; Heywood, I.; Indermuehle, B.; Popping, A.; Sault, R. J.; Whiting, M. T.

    2016-10-01

    Context. Infrared-faint radio sources (IFRS) are a class of radio-loud (RL) active galactic nuclei (AGN) at high redshifts (z ≥ 1.7) that are characterised by their relative infrared faintness, resulting in enormous radio-to-infrared flux density ratios of up to several thousand. Aims: Because of their optical and infrared faintness, it is very challenging to study IFRS at these wavelengths. However, IFRS are relatively bright in the radio regime with 1.4 GHz flux densities of a few to a few tens of mJy. Therefore, the radio regime is the most promising wavelength regime in which to constrain their nature. We aim to test the hypothesis that IFRS are young AGN, particularly GHz peaked-spectrum (GPS) and compact steep-spectrum (CSS) sources that have a low frequency turnover. Methods: We use the rich radio data set available for the Australia Telescope Large Area Survey fields, covering the frequency range between 150 MHz and 34 GHz with up to 19 wavebands from different telescopes, and build radio spectral energy distributions (SEDs) for 34 IFRS. We then study the radio properties of this class of object with respect to turnover, spectral index, and behaviour towards higher frequencies. We also present the highest-frequency radio observations of an IFRS, observed with the Plateau de Bure Interferometer at 105 GHz, and model the multi-wavelength and radio-far-infrared SED of this source. Results: We find IFRS usually follow single power laws down to observed frequencies of around 150 MHz. Mostly, the radio SEDs are steep (α IFRS show statistically significantly steeper radio SEDs than the broader RL AGN population. Our analysis reveals that the fractions of GPS and CSS sources in the population of IFRS are consistent with the fractions in the broader RL AGN population. We find that at least % of IFRS contain young AGN, although the fraction might be significantly higher as suggested by the steep SEDs and the compact morphology of IFRS. The detailed multi

  19. Tools of radio astronomy

    CERN Document Server

    Wilson, Thomas L; Hüttemeister, Susanne

    2013-01-01

    This 6th edition of “Tools of Radio Astronomy”, the most used introductory text in radio astronomy, has been revised to reflect the current state of this important branch of astronomy. This includes the use of satellites, low radio frequencies, the millimeter/sub-mm universe, the Cosmic Microwave Background and the increased importance of mm/sub-mm dust emission. Several derivations and presentations of technical aspects of radio astronomy and receivers, such as receiver noise, the Hertz dipole and  beam forming have been updated, expanded, re-worked or complemented by alternative derivations. These reflect advances in technology. The wider bandwidths of the Jansky-VLA and long wave arrays such as LOFAR and mm/sub-mm arrays such as ALMA required an expansion of the discussion of interferometers and aperture synthesis. Developments in data reduction algorithms have been included. As a result of the large amount of data collected in the past 20 years, the discussion of solar system radio astronomy, dust em...

  20. Radio coverage statistics.

    Science.gov (United States)

    Lynn, W

    1984-01-01

    The Clearinghouse on Development Communication surveyed 135 countries in Asia, Africa, Europe, North and South America, for U.S.A.I.D., to determine the number of radio and television broadcast stations and receivers. Some of the data were obtained from the World Factbook, the World Radio and TV Handbook, and the World Radio and T.V. Facts and Figures, from 1979 to 1981. In those countries where stations are privately owned, audience surveys are often available. In 2 out of 3 developing countries, however, stations are government owned, and no such information is available. Numbers of receivers can sometimes be ascertained from receiver license applications. There is a need for more complete information on broadcast demographics, listening and viewing patterns by the community of world development program personnel.

  1. Galactic radio astronomy

    CERN Document Server

    Sofue, Yoshiaki

    2017-01-01

    This book is a concise primer on galactic radio astronomy for undergraduate and graduate students, and provides wide coverage of galactic astronomy and astrophysics such as the physics of interstellar matter and the dynamics and structure of the Milky Way Galaxy and galaxies. Radio astronomy and its technological development have led to significant progress in galactic astronomy and contributed to understanding interstellar matter and galactic structures. The book begins with the fundamental physics of radio-wave radiation, i.e., black body radiation, thermal emission, synchrotron radiation, and HI and molecular line emissions. The author then gives overviews of ingredients of galactic physics, including interstellar matter such as the neutral (HI), molecular hydrogen, and ionized gases, as well as magnetic fields in galaxies. In addition, more advanced topics relevant to the Galaxy and galaxies are also contained here: star formation, supernova remnants, the Galactic Center and black holes, galactic dynamics...

  2. Radio structure in quasars

    International Nuclear Information System (INIS)

    Barthel, P.D.

    1984-01-01

    In this thesis, observational attention is given to the extended extragalactic radio sources associated with quasars. The isolated compact radio sources, often identified with quasars, are only included in the discussions. Three aspects of the radio structure in quasars and their cosmic evolution are considered: a study of the parsec scale morphology in quasar cores, in relation to the extended morphologies; an investigation of possible epoch dependent hotspot properties as well as a more detailed investigation of this fine scale structure; a VLA project was carried out to obtain morphological information on scales of 0.5 arcsec on high redshift quasars and to investigate possible epoch dependent morphological properties. MERLIN observations at 0.1 arcsec resolution to supplement the VLA data were initiated. (Auth.)

  3. Allow for Uncertainty - Indeterminacy & RadioRadio Research 2013

    OpenAIRE

    Watson, Rob

    2013-01-01

    Radio is faced with the challenge of rapidly changing technology and social practices. How can the study of radio be adapted to account for these changes, and what issues will need to be prioritised in the future.

  4. Radio Emission from Supernovae

    International Nuclear Information System (INIS)

    Weiler, Kurt W.; Panagia, Nino; Sramek, Richard A.; Van Dyk, Schuyler D.; Williams, Christopher L.; Stockdale, Christopher J.; Kelley, Matthew T.

    2009-01-01

    Study of radio supernovae over the past 27 years includes more than three dozen detected objects and more than 150 upper limits. From this work it is possible to identify classes of radio properties, demonstrate conformance to and deviations from existing models, estimate the density and structure of the circumstellar material and, by inference, the evolution of the presupernova stellar wind, and reveal the last stages of stellar evolution before explosion. It is also possible to detect ionized hydrogen along the line of sight, to demonstrate binary properties of the presupernova stellar system, and to detect dumpiness of the circumstellar material.

  5. Intergenerational preferences for radio loudness during automobile driving.

    Science.gov (United States)

    Hanser, Frederick Howard Bateman; Adjei Boakye, Eric; Mikulec, Anthony Alan

    2017-07-01

    The comparative contribution to human noise exposure from the vehicular radio is unknown, as are the radio volume preferences of different generations when driving an automobile. A single vehicle was used to measure radio listening level in decibels of three generations (age 16-17 years, age 32-50 years, and age 51-73 years) in various conditions, ranging from engine off with windows closed to 60 miles per hour (mph) with windows open. No differences in radio loudness based on the sex of the driver were found. Statistically significant differences were identified in preferred signal to noise ratio among multiple vehicular paradigms, with the youngest generation preferring the largest signal to noise ratio in conditions with low background noise. The youngest generation favored the largest signal to noise ratio (radio level above background noise), a preference which waned with increasing background noise. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. A reconfigurable radio architecture for Cognitive Radio in emergency networks

    NARCIS (Netherlands)

    Zhang, Q.; Kokkeler, Andre B.J.; Smit, Gerardus Johannes Maria

    2006-01-01

    Cognitive Radio has been proposed as a promising technology to solve today’s spectrum scarcity problem. Cognitive Radio is able to sense the spectrum to find the free spectrum, which can be optimally used by Cognitive Radio without causing interference to the licensed user. In the scope of the

  7. Spectrum management and radio resource management considering cognitive radio systems

    NARCIS (Netherlands)

    Haartsen, J.C.; Wieweg, Lasse; Huschke, Jörg

    2005-01-01

    International fora and some national administrations define a cognitive radio (CR) as a pioneering radio communication system that would be capable of altering and adapting its transmitter and receiver parameters based on communication and the exchange of information with related detectable radio

  8. Radio Fatwa : Islamic Tanya-Jawab Programmes on Radio Dakwah

    NARCIS (Netherlands)

    Sunarwoto,

    2012-01-01

    The present article is a study of radio fatwa in Indonesia with special reference to the Tanya-Jawab genres in radio dakwah.The concept of fatwa has changed over time. Such Islamic Tanya-Jawab programmes broadcast on radio dakwah are important to understand how fatwa is disseminated by means of

  9. Radio spectra of Gigahertz Peaked Spectrum radio sources

    NARCIS (Netherlands)

    deVries, WH; Barthel, PD; ODea, CP

    A well defined sample of 72 Gigahertz Peaked Spectrum radio sources is compiled, having turnover frequencies in the range of 0.5 - 10 GHz. Using this sample, the canonical GPS radio spectrum is constructed, which is found to have a constant shape, independent of AGN type, redshift or radio

  10. 75 FR 10439 - Cognitive Radio Technologies and Software Defined Radios

    Science.gov (United States)

    2010-03-08

    ..., such as keys, passwords or biometric data. 11. Finally, as software defined radio and security... concerning the use of open source software to implement security features in software defined radios (SDRs... radios; and (2) its policy on the confidentiality of software that controls security measures in software...

  11. Pilot study of the radio-emitting AGN population: the emerging new class of FR 0 radio-galaxies

    Science.gov (United States)

    Baldi, Ranieri D.; Capetti, Alessandro; Giovannini, Gabriele

    2015-04-01

    We present the results of a pilot JVLA project aimed at studying the bulk of the radio-emitting AGN population, that was unveiled by the NVSS/FIRST and SDSS surveys. The key questions are related to the origin of their radio-emission and to its connection with the properties of their hosts. We obtained A-array observations at the JVLA at 1.4, 4.5, and 7.5 GHz for 12 sources, a small but representative subsample. The radio maps reveal compact unresolved or only slightly resolved radio structures on a scale of 1-3 kpc, with the one exception of a hybrid FR I/FR II source extended over ~40 kpc. Thanks to either the new high-resolution maps or to the radio spectra, we isolated the radio core component in most of them. We split the sample into two groups. Four sources have low black hole (BH) masses (mostly ~107 M⊙) and are hosted by blue galaxies, often showing evidence of a contamination from star formation to their radio emission, and are associated with radio-quiet (RQ) AGN. The second group consists in seven radio-loud (RL) AGN, which are located in red massive (~1011 M⊙) early-type galaxies, have high BH masses (≳108 M⊙), and are spectroscopically classified as low excitation galaxies (LEG). These are all characteristics typical of FR I radio galaxies. They also lie on the correlation between radio core power and [O III] line luminosity defined by FR Is. However, they are more core-dominated (by a factor of ~30) than FR Is and show a deficit of extended radio emission. We dub these sources "FR 0" to emphasize their lack of prominent extended radio emission, which is their single distinguishing feature with respect to FR Is. The differences in radio properties between FR 0s and FR Is might be ascribed to an evolutionary effect, with the FR 0 sources undergoing rapid intermittency that prevents the growth of large-scale structures. However, this contrasts with the scenario in which low-luminosity radio-galaxies are fed by continuous accretion of gas from

  12. Radio Broadcast Technology

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 7; Issue 1. Radio Broadcast Technology. Harsh Vardhan. General Article Volume 7 Issue 1 January 2002 pp 53-63. Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/reso/007/01/0053-0063. Keywords. Hertzian ...

  13. Radio Frequency Identification

    Indian Academy of Sciences (India)

    Radio Frequency Identification (RFID) has been around sinceearly 2000. Its use has currently become commonplace as thecost of RFID tags has rapidly decreased. RFID tags have alsobecome more 'intelligent' with the incorporation of processorsand sensors in them. They are widely used now in manyinnovative ways.

  14. A Radio Production Course.

    Science.gov (United States)

    Novak, Glenn D.

    1983-01-01

    Provides a framework for an upper-level basic radio production course. Covers course structure, production assignments, equipment, studio/lab time, grading procedures, textbook and audiovisual materials. Emphasizes theory and practice to provide students with critical and production skills. (PD)

  15. Division x: Radio Astronomy

    NARCIS (Netherlands)

    Taylor, Russ; Chapman, Jessica; Rendong, Nan; Carilli, Christopher; Giovannini, Gabriele; Hills, Richard; Hirabayashi, Hisashi; Jonas, Justin; Lazio, Joseph; Morganti, Raffaella; Rubio, Monica; Shastri, Prajval

    This triennium has seen a phenomenal investment in development of observational radio astronomy facilities in all parts of the globe at a scale that significantly impacts the international community. This includes both major enhancements such as the transition from the VLA to the EVLA in North

  16. Boom Booom Net Radio

    DEFF Research Database (Denmark)

    Grimshaw, Mark Nicholas; Yong, Louisa; Dobie, Ian

    1999-01-01

    Internet radio is one of the growth areas of the Internet but, as this article will show, is fraught with difficulties and frustration for both the modestly-funded broadcaster (bitcaster) and the listener. The article will illustrate some of these problems by means of a short case study of an exi...

  17. Ham Radio is Mir Magic.

    Science.gov (United States)

    Evans, Gary

    1997-01-01

    Presents a classroom activity in which students communicated with U.S. and Russian astronauts via ham radio while they were in orbit on the space station Mir. Gives suggestions for other ham radio classroom activities as well as names of organizations, publications, and grant programs that teachers can access to help in bring ham radio into their…

  18. A Study on Radio Access Technology Selection Algorithms

    CERN Document Server

    Wu, Leijia

    2012-01-01

    This book discusses the basic idea of Common Radio Resource Management (CRRM), especially on the Radio Access Technologies selection part of CRRM. It introduces two interaction functions (information reporting function and RRM decision support function) and four interaction degrees (from low to very high) of CRRM. Four possible CRRM topologies (CRRM server, integrated CRRM, Hierarchical CRRM, and CRRM in user terminals) are described. The book presents different Radio Access Technologies selection algorithms, including single criterion and multiple criteria based algorithms are presented and compares them. Finally, the book analyses the advantages and disadvantages of the different selection algorithms.

  19. Radio resource management using geometric water-filling

    CERN Document Server

    He, Peter; Zhou, Sheng; Niu, Zhisheng

    2014-01-01

    This brief introduces the fundamental theory and development of managing radio resources using a water-filling algorithm that can optimize system performance in wireless communication. Geometric Water-Filling (GWF) is a crucial underlying tool in emerging communication systems such as multiple input multiple output systems, cognitive radio systems, and green communication systems. Early chapters introduce emerging wireless technologies and provide a detailed analysis of water-filling. The brief investigates single user and multi-user issues of radio resource management, allocation of resources

  20. The importance of Radio Quiet Zone (RQZ) for radio astronomy

    Science.gov (United States)

    Umar, Roslan; Abidin, Zamri Zainal; Ibrahim, Zainol Abidin

    2013-05-01

    Most of radio observatories are located in isolated areas. Since radio sources from the universe is very weak, astronomer need to avoid radio frequency interference (RFI) from active spectrum users and radio noise produced by human made (telecommunication, mobile phone, microwave user and many more. There are many observatories around the world are surrounded by a Radio Quiet Zone (RQZ), which is it was set up using public or state laws. A Radio Quiet Zone normally consists of two areas: an exclusive area in which totally radio emissions are forbidden, with restrictions for residents and business developments, and a larger (radius up to 100 km above) coordination area where the power of radio transmission limits to threshold levels. Geographical Information System (GIS) can be used as a powerful tool in mapping large areas with varying RQZ profiles. In this paper, we report the initial testing of the usage of this system in order to identify the areas were suitable for Radio Quiet Zone. Among the important parameters used to develop the database for our GIS are population density, information on TV and telecommunication (mobile phones) transmitters, road networks (highway), and contour shielding. We will also use other information gathered from on-site RFI level measurements on selected 'best' areas generated by the GIS. The intention is to find the best site for the purpose of establishing first radio quiet zones for radio telescope in Malaysia.

  1. Introduction to international radio regulations

    International Nuclear Information System (INIS)

    Radicella, S.M.

    2003-01-01

    These lecture notes contain an overview of basic problems of the International Radio Regulations. Access to the existing information infrastructure, and to that of the future Information Society, depends critically on radio, especially in poor, remote and sparsely populated regions with under-developed telecommunication infrastructure. How the spectrum of radio frequencies is regulated has profound impact on the society, its security, prosperity, and culture. The radio regulations represent a very important framework for an adequate use of radio and should be known by all of those working in the field

  2. WDM-Coherent OCDMA over one single device based on short chip Super Structured Fiber Bragg Gratings.

    Science.gov (United States)

    Amaya, Waldimar; Pastor, Daniel; Baños, Rocio; Garcia-Munoz, Victor

    2011-11-21

    We theoretically propose and demonstrate experimentally a Coherent Direct Sequence OCDMA en/decoder for multi-channel WDM operation based on a single device. It presents a broadband spectral envelope and a periodic spectral pattern that can be employed for en/decoding multiple sub-bands simultaneously. Multi-channel operation is verified experimentally by means of Multi-Band Super Structured Fiber Bragg Gratings with binary phase encoded chips fabricated with 1mm inter-chip separation that provides 4x100 GHz ITU sub-band separation at 1.25 Gbps. The WDM-OCDMA system verification was carried out employing simultaneous encoding of four adjacent sub-bands and two different OCDMA codes. © 2011 Optical Society of America

  3. Measurements of the principal Hugoniots of dense gaseous deuterium−helium mixtures: Combined multi-channel optical pyrometry, velocity interferometry, and streak optical pyrometry measurements

    Directory of Open Access Journals (Sweden)

    Zhi-Guo Li

    2016-10-01

    Full Text Available The accurate hydrodynamic description of an event or system that addresses the equations of state, phase transitions, dissociations, ionizations, and compressions, determines how materials respond to a wide range of physical environments. To understand dense matter behavior in extreme conditions requires the continual development of diagnostic methods for accurate measurements of the physical parameters. Here, we present a comprehensive diagnostic technique that comprises optical pyrometry, velocity interferometry, and time-resolved spectroscopy. This technique was applied to shock compression experiments of dense gaseous deuterium–helium mixtures driven via a two-stage light gas gun. The advantage of this approach lies in providing measurements of multiple physical parameters in a single experiment, such as light radiation histories, particle velocity profiles, and time-resolved spectra, which enables simultaneous measurements of shock velocity, particle velocity, pressure, density, and temperature and expands understanding of dense high pressure shock situations. The combination of multiple diagnostics also allows different experimental observables to be measured and cross-checked. Additionally, it implements an accurate measurement of the principal Hugoniots of deuterium−helium mixtures, which provides a benchmark for the impedance matching measurement technique.

  4. Radio-capacity of ecosystems

    International Nuclear Information System (INIS)

    Kultakhmedov, Yu.; Kultakhmedova-Vyshnyakova, V.

    1997-01-01

    This paper consider a universal approach to ecosystems of different types, based on representation of their radio-capacity. The concept of ecosystem includes reproduction of components (bio-productivity) and conditions such as maintaining of environment quality. Radio-capacity in the case of radionuclide pollution appears in accumulation and redistribution of radionuclides in the ecosystem. As a result the radionuclides are redistributed and buried in soil or lake bottom sediments. Estimation models for the radio-capacity of water and terrestrial ecosystems are represented. The calculations of the radio-capacity factor of water ecosystems are performed, and the high radio-capacity of a freshwater reservoir (F=0.6-0.8) and extremely high radio-capacity of a reservoir cascade (F c =0.99) is shown material from the Dnieper's cascade reservoirs. The methods of radio-capacity estimation of agroecosystems, wood and marine ecosystems are developed. (authors)

  5. The Concept of 'Radio Music'

    DEFF Research Database (Denmark)

    Fjeldsøe, Michael

    2016-01-01

    , educational and didactic effort which would enlighten all of society. For a while it seemed that radio music was considered a genre of its own. To fulfil its function, radio music had to consider technical limitations as well as the educational level and listening modes of the new mass audience. Public radio......, as discussed by Kurt Weill and Paul Hindemith, was at first greeted with great expectations, but soon a more realistic attitude prevailed. Weill, himself a radio critic as well, composed Der Lindberghflug (1929) as a piece of ‘radio music theatre’, but then changed some of its features in order to turn...... it into a didactical play for amateurs, a so-called Lehrstück. The article will present the concept of ‘radio music’ developed within German Neue Sachlichkeit and discuss the relevance of such a concept for current research in the field of radio and music....

  6. Die radio in Afrika

    Directory of Open Access Journals (Sweden)

    S. de Villiers

    1966-03-01

    Full Text Available Omvang van radio-uitsendings in en na Afrika. — Redes vir die versnelde tempo van uitbreiding. — Radio as die geskikste massa-kommunikasiemiddel vir Afrika. — Faktore wat die verspreiding bemoeilik. — Skouspelagtige toename in luistertalle.Toe Plinius, wat in die jaar 79 oorlede is, in sy „Historia Naturalis” verklaar het dat daar altyd iets nuuts uit Afrika afkomstig is, kon hy nouliks voorsien het dat die „iets" negentien eeue later in die lug sou setel wat hierdie reuse-vasteland oorspan — ’n Babelse spraakverwarring en ’n ongekende, verbete woorde-oorlog in die etergolwe, onder meer daarop bereken om die harte en hoofde van derduisendes te verower.

  7. Stations de radio confessionnelles

    OpenAIRE

    Chandès, Gérard

    2013-01-01

    L’auteur cherche à définir les propriétés sonores propres aux radios chrétiennes, principalement catholiques. La première partie de l’article se fonde sur l’étude historique des encycliques et des lettres pastorales du Vatican depuis l’inauguration de Radio Vatican et la seconde partie relève de la sémiologie du son. L’auteur cible les deux caractéristiques principales qui rendent compte de la relation à la transcendance divine : la prédilection pour les longues durées et des effets sonores t...

  8. Radio frequency ion source

    CERN Document Server

    Shen Guan Ren; Gao Fu; LiuNaiYi

    2001-01-01

    The study on Radio Frequency Ion Source is mainly introduced, which is used for CIAE 600kV ns Pulse Neutron Generator; and obtained result is also presented. The RF ion source consists of a diameter phi 25 mm, length 200 mm, coefficient of expansion =3.5 mA, beam current on target >=1.5 mA, beam spot =100 h.

  9. MUSIC RADIO-JOURNALISM

    OpenAIRE

    Dubovtceva Ludmila I.

    2014-01-01

    The article is based on years of practical experience, the author highlights the main radio genres in which music correspondent, music reviewer, music commentator, and music leading and a disc jockey work. Theoretical principles of their creative activities are analyzed in common journalistic genres, such as interview, reportage, talk show, live broadcast, radiofilm, as well as specialized genres like concert on demand and music competition. Journalist’ speech is seen as a logical element, th...

  10. Radio Frequency Interference Mitigation

    Science.gov (United States)

    An, T.; Chen, X.; Mohan, P.; Lao, B. Q.

    2017-09-01

    The observational facilities of radio astronomy keep constant upgrades and developments to achieve better capabilities including increasing the time of the data recording and frequency resolutions, and increasing the receiving and recording bandwidth. However in contrast, only a limited spectrum resource has been allocated to radio astronomy by the International Telecommunication Union, resulting in that the radio observational instrumentations are inevitably exposed to undesirable radio frequency interference (RFI) signals which originate mainly from the terrestrial human activity and are becoming stronger with time. RFIs degrade the quality of data and even lead to invalid data. The impact of RFIs on scientific outcome becomes more and more serious. In this article, the requirement for RFI mitigation is motivated, and the RFI characteristics, mitigation techniques, and strategies are reviewed. The mitigation strategies adopted at some representative observatories, telescopes, and arrays are also introduced. The advantages and shortcomings of the four classes of RFI mitigation strategies are discussed and presented, applicable at the connected causal stages: preventive, pre-detection, pre-correlation, and post-correlation. The proper identification and flagging of RFI is the key to the reduction of data loss and improvement in data quality, and is also the ultimate goal of developing RFI mitigation technique. This can be achieved through a strategy involving a combination of the discussed techniques in stages. The recent advances in the high speed digital signal processing and high performance computing allow for performing RFI excision of the large data volumes generated from large telescopes or arrays in both real time and offline modes, aiding the proposed strategy.

  11. Cognitive radio networks efficient resource allocation in cooperative sensing, cellular communications, high-speed vehicles, and smart grid

    CERN Document Server

    Jiang, Tao; Cao, Yang

    2015-01-01

    PrefaceAcknowledgmentsAbout the AuthorsIntroductionCognitive Radio-Based NetworksOpportunistic Spectrum Access NetworksCognitive Radio Networks with Cooperative SensingCognitive Radio Networks for Cellular CommunicationsCognitive Radio Networks for High-Speed VehiclesCognitive Radio Networks for a Smart GridContent and OrganizationTransmission Slot Allocation in an Opportunistic Spectrum Access NetworkSingle-User Single-Channel System ModelProbabilistic Slot Allocation SchemeOptimal Probabilistic Slot AllocationBaseline PerformanceExponential DistributionHyper-Erlang DistributionPerformance An

  12. Spectral differences between the jets in `radio-loud' and `radio-quiet' hard-state black hole binaries

    Science.gov (United States)

    Espinasse, M.; Fender, R.

    2018-01-01

    We have compiled from the available literature a large set of radio measurements of black hole binaries in the hard X-ray state for which measurements of the gigahertz frequency radio spectral index are possible. We separate the sample into 'radio-loud' and 'radio-quiet' subsets based upon their distribution in the radio-X-ray plane and investigate the distribution of radio spectral indices within each subset. The distribution of spectral indices of the 'radio-loud' subset is well described by a Gaussian distribution with mean spectral index α = +0.2 and standard deviation 0.2 (here spectral index is defined such that a positive spectral index means more flux at higher frequencies). The sparser sample for the 'radio-quiet' subset can be approximated, less well, by a Gaussian with mean α = -0.2 and standard deviation 0.3; alternatively, the simple mean of the distribution of the radio-quiet subset is -0.3. The two spectral index distributions are different at high statistical significance. Confirming previous work in the literature, we test to see if the differences in observed spectra could result from different distributions of jet viewing angles, but find no evidence for this. We conclude therefore that the jets in the two groups are physically different in some way, and briefly discuss possible origins and further possible diagnostics. Finally, we note that extrapolating to lower frequencies the two subsets move closer together in the radio-X-ray plane, and approximately merge into a single distribution at around 400 MHz.

  13. RADIO-LOUD ACTIVE GALACTIC NUCLEUS: IS THERE A LINK BETWEEN LUMINOSITY AND CLUSTER ENVIRONMENT?

    International Nuclear Information System (INIS)

    Ineson, J.; Croston, J. H.; Hardcastle, M. J.; Jarvis, M.; Kraft, R. P.; Evans, D. A.

    2013-01-01

    We present here the first results from the Chandra ERA (Environments of Radio-loud AGN) Large Project, characterizing the cluster environments of a sample of 26 radio-loud active galactic nuclei (AGNs) at z ∼ 0.5 that covers three decades of radio luminosity. This is the first systematic X-ray environmental study at a single epoch, and has allowed us to examine the relationship between radio luminosity and cluster environment without the problems of Malmquist bias. We have found a weak correlation between radio luminosity and host cluster X-ray luminosity, as well as tentative evidence that this correlation is driven by the subpopulation of low-excitation radio galaxies, with high-excitation radio galaxies showing no significant correlation. The considerable scatter in the environments may be indicative of complex relationships not currently included in feedback models.

  14. THE RADIO ACTIVITY-ROTATION RELATION OF ULTRACOOL DWARFS

    International Nuclear Information System (INIS)

    McLean, M.; Berger, E.; Reiners, A.

    2012-01-01

    We present a new radio survey of about 100 late-M and L dwarfs undertaken with the Very Large Array. The sample was chosen to explore the role of rotation in the radio activity of ultracool dwarfs. As part of the survey we discovered radio emission from three new objects, 2MASS J 0518113 – 310153 (M6.5), 2MASS J 0952219 – 192431 (M7), and 2MASS J 1314203 + 132001 (M7), and made an additional detection of LP 349-25 (M8). Combining the new sample with results from our previous studies and from the literature, we compile the largest sample to date of ultracool dwarfs with radio observations and measured rotation velocities (167 objects). In the spectral type range M0-M6 we find a radio activity-rotation relation, with saturation at L rad /L bol ≈ 10 –7.5 above vsin i ≈ 5 km s –1 , similar to the relation in Hα and X-rays. However, at spectral types ∼> M7 the ratio of radio to bolometric luminosity increases significantly regardless of rotation velocity, and the scatter in radio luminosity increases. In particular, while the most rapid rotators (vsin i ∼> 20 km s –1 ) exhibit 'super-saturation' in X-rays and Hα, this effect is not seen in the radio. We also find that ultracool dwarfs with vsin i ∼> 20 km s –1 have a higher radio detection fraction by about a factor of three compared to objects with vsin i ∼ –1 . When measured in terms of the Rossby number (Ro), the radio activity-rotation relation follows a single trend and with no apparent saturation from G to L dwarfs and down to Ro ∼ 10 –3 ; in X-rays and Hα there is clear saturation at Ro ∼ rad /R 2 * ) as a function of Ro. The continued role of rotation in the overall level of radio activity and in the fraction of active sources, and the single trend of L rad /L bol and L rad /R 2 * as a function of Ro from G to L dwarfs, indicates that rotation effects are important in regulating the topology or strength of magnetic fields in at least some fully convective dwarfs. The fact that

  15. Flexible Adaptation in Cognitive Radios

    CERN Document Server

    Li, Shujun

    2013-01-01

    This book provides an introduction to software-defined radio and cognitive radio, along with methodologies for applying knowledge representation, semantic web, logic reasoning and artificial intelligence to cognitive radio, enabling autonomous adaptation and flexible signaling. Readers from the wireless communications and software-defined radio communities will use this book as a reference to extend software-defined radio to cognitive radio, using the semantic technology described. Readers with a background in semantic web and artificial intelligence will find in this book the application of semantic web and artificial intelligence technologies to wireless communications. For readers in networks and network management, this book presents a new approach to enable interoperability, collaborative optimization and flexible adaptation of network components. Provides a comprehensive ontology covering the core concepts of wireless communications using a formal language; Presents the technical realization of using a ...

  16. The properties of radio ellipticals

    International Nuclear Information System (INIS)

    Sparks, W.B.; Disney, M.J.; Rodgers, A.W.

    1984-01-01

    Optical and additional radio data are presented for the bright galaxies of the Disney and Wall survey (1977 Mon. Not. R. Astron. Soc. 179, 235). These data form the basis of a statistical comparison of the properties of radio elliptical galaxies to radio-quiet ellipticals. The correlations may be explained by the depth of the gravitational potential well in which the galaxy resides governing the circumstances under which an elliptical galaxy rids itself of internally produced gas. (author)

  17. Military Mail Radio

    Directory of Open Access Journals (Sweden)

    Bîlbîie Răduţ

    2015-12-01

    Full Text Available Cultural and scientific personalities from the army, military experts and creators of the doctrine have collaborated with the radio from the beginnings of radiophony, the educational role of this new, persuasive communication channel being evident not only for Romania or the Romanian army but also for all the countries that had radiophony services. This happens in the context of the end of the crisis and the start of economic and social development, promoting culture, creating a solid class of peasants with a certain social status, in villages, together with the priest, teacher and gendarme, increasing of the number of subscriptions and development of the Romanian radiophony.

  18. Radio frequency pulse compression

    International Nuclear Information System (INIS)

    Farkas, Z.D.

    1988-12-01

    High gradients require peak powers. One possible way to generate high peak powers is to generate a relatively long pulse at a relatively low power and compress it into a shorter pulse with higher peak power. It is possible to compress before dc to rf conversion as is done for the relativistic klystron or after dc to rf conversion as is done with SLED. In this note only radio frequency pulse compression (RFPC) is considered. Three methods of RFPC will be discussed: SLED, BEC, and REC. 3 refs., 8 figs., 1 tab

  19. La radio digital.

    OpenAIRE

    Cortés, Carlos

    2005-01-01

    La radio digital es un producto de la llamada convergencia digital. Desde la década de1990, nuevos dispositivos electrónicos de recepción y reproducción digital, incluyendo ciertos teléfonos celulares, se comunican entre sí, en los entornos de redes, mediante sencillas interfaces. Por esta razón, ofrecen ventajas antes inexistentes en los medios analógicos. A partir de sistemas de adquisición y producción digital, que comenzaron como simples cintas de audio digital (DAT), la evolución tec...

  20. Central radio sources

    International Nuclear Information System (INIS)

    Phinney, E.S.

    1985-01-01

    The compact radio sources in the nuclei of most active galaxies lie closer to their centers of activity than any other region accessible to observation, excepting only the broad emission line region. They provide uniquely strong evidence for bulk motion of matter at relativistic velocities, encouraging the belief that the activity originates in a gravitational potential well whose escape velocity is of the order of the speed of light. The observational facts are reviewed as well as several theoretical pictures of them. Those places where systematic observations could help to distinguish the true theoretical picture from the many competing forgeries are emphasized. 76 references

  1. Pluralismo, radio e Internet

    OpenAIRE

    Bruce Girard

    2015-01-01

    En muchas ocasiones de ha oído hablar que internet y las nuevas tecnologías de la comunicación llevarán a la humanidad a un mundo homogeneizado en donde todos compartirán la misa cultura del “ciberespacio” y hablarán el mismo lenguaje. Nuevas iniciativas en América Latina combinan la tecnología de punta y la radio para poner fin a este mito y contribuir a una comunicación más democrática.

  2. Radio-induced brain lesions

    Directory of Open Access Journals (Sweden)

    Gorgan Mircea Radu

    2014-03-01

    Full Text Available Introduction : Radiotherapy, an important tool in multimodal oncologic treatment, can cause radio-induced brain lesion development after a long period of time following irradiation.

  3. Radio Frequency Anechoic Chamber Facility

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Supports the design, manufacture, and test of antenna systems. The facility is also used as an electromagnetic compatibility/radio frequency interference...

  4. The coexistence of cognitive radio and radio astronomy

    NARCIS (Netherlands)

    Bentum, Marinus Jan; Boonstra, A.J.; Baan, W.A.

    2009-01-01

    An increase of the efficiency of spectrum usage requires the development of new communication techniques. Cognitive radio may be one of those new technique, which uses unoccupied frequency bands for communications. This will lead to more power in the bands and therefore an increasing level of Radio

  5. Radio Astronomy and the Giant Metre-Wave Radio Telescope

    Indian Academy of Sciences (India)

    of light into its constituent colours (or wavelengths, since light of different colours corresponds to light of different wavelengths) is called a ... together to form neutral atoms). The diffuse gas that is found between stars is also a strong emitter of radio-waves. In general, optical telescopes show us where stars are, while radio.

  6. Radio Jove: Citizen Science for Jupiter Radio Astronomy

    Science.gov (United States)

    Higgins, C. A.; Thieman, J.; Reyes, F. J.; Typinski, D.; Flagg, R. F.; Greenman, W.; Brown, J.; Ashcraft, T.; Sky, J.; Cecconi, B.; Garcia, L. N.

    2016-12-01

    The Radio Jove Project (http://radiojove.gsfc.nasa.gov) has been operating as an educational activity for 18 years to introduce radio astronomy activities to students, teachers, and the general public. Participants may build a simple radio telescope kit, make scientific observations, and interact with radio observatories in real-time over the Internet. Recently some of our dedicated citizen science observers have upgraded their systems to better study radio emission from Jupiter and the Sun by adding dual-polarization spectrographs and wide-band antennas in the frequency range of 15-30 MHz. Some of these observations are being used in conjunction with professional telescopes such as the Long Wavelength Array (LWA), the Nancay Decametric Array, and the Ukrainian URAN2 Radio Telescope. In particular, there is an effort to support the Juno Mission radio waves instrument at Jupiter by using citizen science ground-based data for comparison and polarization verification. These data will be archived through a Virtual European Solar and Planetary Access (VESPA) archive (https://voparis-radiojove.obspm.fr/radiojove/welcome) for use by the amateur and professional radio science community. We overview the program and display recent observations that will be of interest to the science community.

  7. Radio Astronomy and the Giant Metre-Wave Radio Telescope

    Indian Academy of Sciences (India)

    background, listening intently to this extra-terrestrial signal. For many people of that generation, this is likely to have been their first, and most likely only, exposure to radio astronomy. In some ways, however, what is more surprising is that the general public has some exposure to radio astronomy at all, let alone through a.

  8. Dramatugi Penyiar Radio

    Directory of Open Access Journals (Sweden)

    Hastika Yanti Nora

    2009-07-01

    Full Text Available Dramaturgy is the work of Erving Goffman. He wrote "Presentation of Self in Everyday Life" in '1959. Following the theatrical analogy, Goffman spoke of a front stage and back stage. The front stage is that part of the performance that generally functions in rather fixed and general ways to define the situation for those who observed the performance. The back stage is situation where facts suppressed in the front or various kinds of informal actions may appear. A back stage is usually adjacent to the front stage, but it also cut off from it. Everyone in this world have to run his role in their everyday life. It also a radio announcer. As an actor, they have to be a nice and friendy person when they perform to make air personality, that is  a good  impression, from their audience. But before their perform in the front stage, there so much to do to prepare in the backstage. The front and back stage is radio announcer dramaturgy.

  9. Multi-channel automotive night vision system

    Science.gov (United States)

    Lu, Gang; Wang, Li-jun; Zhang, Yi

    2013-09-01

    A four-channel automotive night vision system is designed and developed .It is consist of the four active near-infrared cameras and an Mulit-channel image processing display unit,cameras were placed in the automobile front, left, right and rear of the system .The system uses near-infrared laser light source,the laser light beam is collimated, the light source contains a thermoelectric cooler (TEC),It can be synchronized with the camera focusing, also has an automatic light intensity adjustment, and thus can ensure the image quality. The principle of composition of the system is description in detail,on this basis, beam collimation,the LD driving and LD temperature control of near-infrared laser light source,four-channel image processing display are discussed.The system can be used in driver assistance, car BLIS, car parking assist system and car alarm system in day and night.

  10. Multi-Channel Maximum Likelihood Pitch Estimation

    DEFF Research Database (Denmark)

    Christensen, Mads Græsbøll

    2012-01-01

    . This essentially means that the model allows for different conditions in the various channels, like different signal-to-noise ratios, microphone characteristics and reverberation. Moreover, the method does not assume that a certain array structure is used but rather relies on a more general model and is hence...

  11. Multi-channel gas-delivery system

    Energy Technology Data Exchange (ETDEWEB)

    Rozenzon, Yan; Trujillo, Robert T.; Beese, Steven C.

    2016-09-13

    One embodiment of the present invention provides a gas-delivery system for delivering reaction gas to a reactor chamber. The gas-delivery system includes a main gas-inlet port for receiving reaction gases and a gas-delivery plate that includes a plurality of gas channels. A gas channel includes a plurality of gas holes for allowing the reaction gases to enter the reactor chamber from the gas channel. The gas-delivery system further includes a plurality of sub-gas lines coupling together the main gas-inlet port and the gas-delivery plate, and a respective sub-gas line is configured to deliver a portion of the received reaction gases to a corresponding gas channel.

  12. Channel Power in Multi-Channel Environments

    NARCIS (Netherlands)

    M.G. Dekimpe (Marnik); B. Skiera (Bernd)

    2004-01-01

    textabstractIn the literature, little attention has been paid to instances where companies add an Internet channel to their direct channel portfolio. However, actively managing multiple sales channels requires knowing the customers’ channel preferences and the resulting channel power. Two key

  13. Multi-channel medical imaging system

    Science.gov (United States)

    Frangioni, John V

    2013-12-31

    A medical imaging system provides simultaneous rendering of visible light and fluorescent images. The system may employ dyes in a small-molecule form that remain in the subject's blood stream for several minutes, allowing real-time imaging of the subject's circulatory system superimposed upon a conventional, visible light image of the subject. The system may provide an excitation light source to excite the fluorescent substance and a visible light source for general illumination within the same optical guide used to capture images. The system may be configured for use in open surgical procedures by providing an operating area that is closed to ambient light. The systems described herein provide two or more diagnostic imaging channels for capture of multiple, concurrent diagnostic images and may be used where a visible light image may be usefully supplemented by two or more images that are independently marked for functional interest.

  14. Customer Engagement Tool (Multi Channel Communication)

    Data.gov (United States)

    Social Security Administration — Add new infrastructure within SSA's Enterprise Architecture to allow interactions over multiple, yet to be defined, channels. Possibilities include: Provide a portal...

  15. Radio design in nanometer technologies

    CERN Document Server

    Ismail, Mohammed

    2006-01-01

    This is the first volume that looks at the integrated radio design problem as a "piece of a big puzzle" Most books discuss more on communications or more on hardware but not both, this book strikes the right balance between the two and provides the reader with a holistic view of the subject of radio design: current and future trends.

  16. Tuning in to pavement radio

    NARCIS (Netherlands)

    Ellis, S.D.K.

    1989-01-01

    This article describes a phenomenon known all over Africa, for which there is no really satisfactory term in English but which is summed up in the French term 'radio trottoir', literally 'pavement radio'. It may be defined as the popular and unofficial discussion of current affairs in Africa,

  17. Cognitive Radio for Emergency Networks

    NARCIS (Netherlands)

    Zhang, Q.; Kokkeler, Andre B.J.; Smit, Gerardus Johannes Maria

    2006-01-01

    In the scope of the Adaptive Ad-hoc Freeband (AAF) project, an emergency network built on top of Cognitive Radio is proposed to alleviate the spectrum shortage problem which is the major limitation for emergency networks. Cognitive Radio has been proposed as a promising technology to solve

  18. Radio Propagation into Modern Buildings

    DEFF Research Database (Denmark)

    Rodriguez Larrad, Ignacio; Nguyen, Huan Cong; Jørgensen, Niels T.K.

    2014-01-01

    constructions. These materials are used in favor of achieving a proper level of thermal isolation, but it has been noticed that they can impact heavily on radio signal propagation. This paper presents a measurement-based analysis of the outdoor-to-indoor attenuation experienced in several modern constructions...... presented along the paper are useful for future radio network planning considerations....

  19. RADIO NOISE ADVANCES SEXUAL MATURITY

    African Journals Online (AJOL)

    ansistf-lewis

    groups for a regression of body weight on age at first egg, indicating that accelerated growth did not contribute to the advance in ... clocks that operated the radios and the lights. The other two chambers ... Mean body weight at first egg for the birds given the radio noise was not significantly different from the controls (Table).

  20. Dust tori in radio galaxies

    NARCIS (Netherlands)

    van der Wolk, G.; Barthel, P. D.; Peletier, R. F.; Pel, J. W.

    Aims. We investigate the quasar - radio galaxy unification scenario and detect dust tori within radio galaxies of various types. Methods. Using VISIR on the VLT, we acquired sub-arcsecond (similar to 0.40 '') resolution N-band images, at a wavelength of 11.85 mu m, of the nuclei of a sample of 27

  1. Compressed Sensing Methods in Radio Receivers Exposed to Noise and Interference

    DEFF Research Database (Denmark)

    Pierzchlewski, Jacek

    implemented standard for mobile communication, implements performance parameters which not so long ago were available only for cable networks. There is also observed a trend to implement many radio receivers in a single integrated circuit. Radio receivers become more software-based, due to signicant increase...

  2. Interactive radio instruction: developing instructional methods.

    Science.gov (United States)

    Friend, J

    1989-01-01

    The USAID has, since 1972, funded the development of a new methodology for educational radio for young children through 3 projects: the Radio Mathematics PRoject of Nicaragua, the Radio Language Arts Project of Kenya, and the Radio Science PRoject of Papua New Guinea. These projects developed math programs for grades 1-4 and English as a second language for grades 1-3; programs to teach science in grades 4-6 are now being developed. Appropriate techniques were developed to engage young children actively in the learning process. Lessons are planned as a "conversation" between the children and the radio; scripts are written as 1/2 of a dialogue, with pauses carefully timed so that written as 12 of a dialogue, with pauses carefully timed so that students can contribute their 1/2. Teaching techniques used in all 3 projects include choral responses, simultaneous individual seatwork, and activities using simple materials such as pebbles and rulers. Certain techniques were specific to the subject being taught, or to the circumstances in which the lessons were to be used. Patterned oral drill was used frequently in the English lessons, including sound-cued drills. "Deferred" oral responses were used often in the math lessons. In this method, the children are instructed to solve a problem silently, not giving the answer aloud until requested, thus allowing time for even the slower children to participate. "One-child" questions were used in both English and science: the radio asks a question to be answered by a single child, who is selected on the spot by the classroom teacher. This allows for open-ended questions, but also requires constant supervision of the classroom teacher. Songs and games were used in all programs, and extensively for didactic purposes in the teaching of English. Instructions for science activities are often more complex than in other courses, particularly when the children are using science apparatus, especially when they work in pairs to share scarce

  3. Radio propagation measurement and channel modelling

    CERN Document Server

    Salous, Sana

    2013-01-01

    While there are numerous books describing modern wireless communication systems that contain overviews of radio propagation and radio channel modelling, there are none that contain detailed information on the design, implementation and calibration of radio channel measurement equipment, the planning of experiments and the in depth analysis of measured data. The book would begin with an explanation of the fundamentals of radio wave propagation and progress through a series of topics, including the measurement of radio channel characteristics, radio channel sounders, measurement strategies

  4. CURIE: Cubesat Radio Interferometry Experiment

    Science.gov (United States)

    Sundkvist, D. J.; Saint-Hilaire, P.; Bain, H. M.; Bale, S. D.; Bonnell, J. W.; Hurford, G. J.; Maruca, B.; Martinez Oliveros, J. C.; Pulupa, M.

    2016-12-01

    The CUbesat Radio Interferometry Experiment (CURIE) is a proposed two-element radio interferometer, based on proven and developed digital radio receivers and designed to fit within a Cubesat platform. CURIE will launch as a 6U Cubesat and then separate into two 3U Cubesats once in orbit. CURIE measures radio waves from 0.1-19MHz, which must be measured from space, as those frequencies fall below the cutoff imposed by Earth's ionosphere. The principal science objective for CURIE is to use radio interferometry to study radio burst emissions from solar eruptive events such as flares and coronal mass ejections (CMEs) in the inner heliosphere, providing observations important for our understanding of the heliospheric space weather environment. The influence of space weather can be felt at Earth and other planets, as radiation levels increase and lead to auroral activity and geomagnetic effects. CURIE will be able to determine the location and size of radio burst source regions and then to track their movement outward from the Sun. In addition to the primary objective CURIE will measure the gradients of the local ionospheric density and electron temperature on the spatial scale of a few kilometers, as well as create an improved map of the radio sky at these unexplored frequencies. A space based radio interferometry observatory has long been envisioned, in orbit around the Earth or the Moon, or on the far side of the Moon. Beyond its important science objectives, CURIE will prove that the concept of a dedicated space-based interferometer can be realized by using relatively cheap Cubesats. CURIE will therefore not only provide new important science results but also serve as a pathfinder in the development of new space-based radio observation techniques for helio- and astro-physics.

  5. Implementing Software Defined Radio

    CERN Document Server

    Grayver, Eugene

    2013-01-01

    Software Defined Radio makes wireless communications easier, more efficient, and more reliable. This book bridges the gap between academic research and practical implementation. When beginning a project, practicing engineers, technical managers, and graduate students can save countless hours by considering the concepts presented in these pages. The author covers the myriad options and trade-offs available when selecting an appropriate hardware architecture. As demonstrated here, the choice between hardware- and software-centric architecture can mean the difference between meeting an aggressive schedule and bogging down in endless design iterations. Because of the author’s experience overseeing dozens of failed and successful developments, he is able to present many real-life examples. Some of the key concepts covered are: Choosing the right architecture for the market – laboratory, military, or commercial Hardware platforms – FPGAs, GPPs, specialized and hybrid devices Standardization efforts to ens...

  6. MUSIC RADIO-JOURNALISM

    Directory of Open Access Journals (Sweden)

    Dubovtceva Ludmila I.

    2014-04-01

    Full Text Available The article is based on years of practical experience, the author highlights the main radio genres in which music correspondent, music reviewer, music commentator, and music leading and a disc jockey work. Theoretical principles of their creative activities are analyzed in common journalistic genres, such as interview, reportage, talk show, live broadcast, radiofilm, as well as specialized genres like concert on demand and music competition. Journalist’ speech is seen as a logical element, the incoming with music in art-structural relationships. However, it does not become the predominant sound layer and aims to harmonious correlation or local penetration into music opus. In addition, important links in music journalism are defined the auxiliary "offscreen" editor's job and keeping the original sound archive. The author cites a number of own work examples on the air.

  7. Radio-isotopic tracers

    International Nuclear Information System (INIS)

    Wolfangel, R.G.

    1976-01-01

    The invention concerns the dispersions that may be used for preparing radio-isotopic tracers, technetium labelled dispersions, processes for preparing these dispersions and their use as tracers. Technetium 99m sulphur colloids are utilized as scintillation tracers to give a picture of the reticulo-endothelial system, particularly the liver and spleen. A dispersion is provided which only requires the addition of a radioactive nuclide to form a radioactively labelled dispersion that can be injected as a tracer. It is formed of a colloid of tin sulphur dispersed in an aqueous buffer solution. Such a reagent has the advantage of being safe and reliable and is easier to use. The colloid can be prepared more quickly since additions of several different reagents are avoided. There is no need to heat up and no sulphuretted hydrogen, which is a toxic gas, is used [fr

  8. Radio opaque gloves

    International Nuclear Information System (INIS)

    Whittaker, A.V.; Whittaker, R.E. Jr.; Goldstrom, R.A.; Shipko, F.J.

    1975-01-01

    Radiation shielding garments and accessories, such as radio-opaque gloves for surgeons, shielding against the harmful x-ray radiation in a fluoroscopic zone, are advantageously different from garments for shielding from other medical uses of x-rays. Such garments are provided with zones of differing opacity, whereby desired sensitivity and ''feel'' through the glove material is retained. One feature is the provision of an ''opacity gradient'' across the glove cross section with opacity being relatively low at the fingertip area (lesser shield-thickness), but relatively high at the less nonprehensile hand zones, such as the palm. Glove fabrication techniques for achieving such an opacity gradient are described. (U.S.)

  9. AGONIZAN RADIOS MINERAS

    Directory of Open Access Journals (Sweden)

    Raquel Salinas

    2015-01-01

    Full Text Available Se ofrece un amplio análisis sobre la industria electoral, recordando que un candidato a presidente es "un producto para la venta". Se Desmenuzan las estrategias utilizadas en el plebiscito chileno,las elecciones norteamericanas con el NO a BUSH. El Mercadeo Social es una nueva metodología utilizada en proyectos de desarrollo a nivel de campo por ello se hace un esclarecimiento y clarifica el vínculo con la comunicación. Se agrega temas como: Los modelos de recepción de mensajes cuyos marcos conceptuales y metodologías aún no se han adaptado al potencial de esta línea de trabajo.Se analiza la agonía de las radios mineras en Bolivia en la que 42 años de historia y heroísmo se desmoronan.

  10. The Radio Language Arts Project: adapting the radio mathematics model.

    Science.gov (United States)

    Christensen, P R

    1985-01-01

    Kenya's Radio Language Arts Project, directed by the Academy for Educational Development in cooperation with the Kenya Institute of Education in 1980-85, sought to teach English to rural school children in grades 1-3 through use of an intensive, radio-based instructional system. Daily 1/2 hour lessons are broadcast throughout the school year and supported by teachers and print materials. The project further was aimed at testing the feasibility of adaptation of the successful Nicaraguan Radio Math Project to a new subject area. Difficulties were encountered in articulating a language curriculum with the precision required for a media-based instructional system. Also a challenge was defining the acceptable regional standard for pronunciation and grammar; British English was finally selected. An important modification of the Radio Math model concerned the role of the teacher. While Radio Math sought to reduce the teacher's responsibilities during the broadcast, Radio Language Arts teachers played an important instructional role during the English lesson broadcasts by providing translation and checks on work. Evaluations of the Radio language Arts Project suggest significant gains in speaking, listening, and reading skills as well as high levels of satisfaction on the part of parents and teachers.

  11. A Radio Astronomy Science Education Partnership - GAVRT and Radio JOVE

    Science.gov (United States)

    Higgins, C. A.; Thieman, J. R.; Bunnell, K.; Soholt, G.

    2009-12-01

    The planet Jupiter provides an excellent subject to educate, engage, and inspire students and teachers to learn science. The Goldstone Apple-Valley Radio Telescope (GAVRT) program (http://www.lewiscenter.org/gavrt) and The Radio JOVE project (http://radiojove.gsfc.nasa.gov) each have a long history of allowing students and teachers to interact with scientists and real radio telescopes. The upcoming Juno mission to Jupiter (2011 launch) allows both GAVRT and Radio JOVE to combine efforts and engage with the NASA Juno mission, thus increasing the excitement and learning potential for teachers, students, and the general public. Teachers can attend workshops for training to operate a 34-meter radio telescope and/or build their own simple radio telescope, both of which can be used directly in the classroom. We will overview some classroom activities and highlight some teacher-student experiences. In addition, we will update our efforts on greater Web-based control of the radio telescopes, as well as highlight our upcoming workshops to allow better access for teachers in different parts of the Country.

  12. Annals of the International Geophysical Year solar radio emission during the International Geophysical Year

    CERN Document Server

    Smerd, S F

    1969-01-01

    Annals of the International Geophysical Year, Volume 34: Solar Radio Emission During the International Geophysical Year covers the significant solar radio emission events observed during the International Geophysical Year (IGY). This book is composed of six chapters, and begins with a summary of tabulated quantities describing solar radio emission during the IGY. The tabulated figures illustrate the method of recording the position of radio sources on the sun, the use of symbols in describing the structure of bursts observed at single frequencies, and the different types used in a spectral

  13. Radio Astronomy Explorer /RAE/. I - Observations of terrestrial radio noise.

    Science.gov (United States)

    Herman, J. R.; Caruso, J. A.; Stone, R. G.

    1973-01-01

    Radio Astronomy Explorer (RAE) I data are analyzed to establish characteristics of HF terrestrial radio noise at an altitude of about 6000 km. Time and frequency variations in amplitude of the observed noise well above cosmic noise background are explained on the basis of temporal and spatial variations in ionospheric critical frequency coupled with those in noise source distributions. It is shown that terrestrial radio noise regularly breaks through the ionosphere and reaches RAE with magnitudes 15 dB and more above cosmic noise background, on frequencies above the F-layer critical frequency.

  14. Tectonic and climatic controls on seafloor sedimentary processes from analysis of multi-beam sonar and multi-channel seismic data collected during the Galicia 3D seismic experiment.

    Science.gov (United States)

    Gibson, J. C.; Shillington, D. J.; Sawyer, D. S.; Morgan, J.; Ranero, C. R.; Reston, T. J.; Dash, R. K.; Payne, B. A.

    2016-12-01

    Due to a very low sedimentation rate, the deep Galicia Basin provides a unique opportunity to gain insight into the control by recent tectonic and/or climatic processes on deep-sea sediment delivery. In order to study the sediment delivery system we use morphological and geophysical attributes drawn from multi-beam (MB) sonar bathymetry/backscatter data supplemented with 3D multi-channel seismic (MCS) surface seismic attributes collected using R/V Marcus G. Langseth during the Galicia 3D seismic experiment (2013). We observe a submarine canyon that is controlled by rift-block geometry and connected to the Galicia Bank. Relatively low reflectivity is associated with the canyon, but a large ( 125 km2) tongue-shaped area of high reflectively is seen in the deep abyssal plain seaward of the canyon mouth. This suggests that processes such as flow stripping are taking place resulting in relatively coarse grain deposition in the basin. This interpretation is further supported by the presence of variable wavelength (400m-5km) sediment waves and discrete linear bands of high reflectivity. Spectral analysis of the sediment waves reveals short-wavelength overprinting of relatively long-wavelength features suggesting a relatively recent shift in the flow regime. The spectrums also provide quantitative measurement of the wavelength, amplitude, and phase of the reflectivity relative to the bathymetry from which we make estimations as to grain size and flow velocity. Additionally, attributes drawn from MB (e.g., slope, aspect) and MCS (e.g., instantaneous frequency) spanning the sediment wave field are used for multivariate least squares analysis of the spatial distribution of reflectivity in respect to the morphology of the sediment waves, which further supports the spectral analysis. The large tongue shaped high reflectivity feature extending 30km into the basin is analyzed in respect to geometry and variable reflectivity. The results of the above analyses along with

  15. The Nature of Coherent Radio Emission from Pulsars

    Indian Academy of Sciences (India)

    72

    waves excited by the coherent curvature radiation are polarized either along the k and local magnetic field plane (O-mode) or perpendicular to the k and magnetic field plane (X-mode). The single pulse observations suggest that pulsar radio emission is excited by coher- ent curvature radiation which is a definitive solution to.

  16. Variations in translating Poceza m'Madzulo radio narrative texts ...

    African Journals Online (AJOL)

    This study is a follow-up to an earlier one that overviewed the dramatic style and artistry of Julius Chongo, a Zambian radio narrative performer, in relation to a single narrative (Wendland 2014*). In that investigation I did not develop in detail the translation strategy that I employed when rendering the original Chewa ...

  17. V-FASTR: THE VLBA FAST RADIO TRANSIENTS EXPERIMENT

    International Nuclear Information System (INIS)

    Wayth, Randall B.; Tingay, Steven J.; Brisken, Walter F.; Deller, Adam T.; Majid, Walid A.; Thompson, David R.; Wagstaff, Kiri L.

    2011-01-01

    Recent discoveries of dispersed, non-periodic impulsive radio signals with single-dish radio telescopes have sparked significant interest in exploring the relatively uncharted space of fast transient radio signals. Here we describe V-FASTR, an experiment to perform a blind search for fast transient radio signals using the Very Long Baseline Array (VLBA). The experiment runs entirely in a commensal mode, alongside normal VLBA observations and operations. It is made possible by the features and flexibility of the DiFX software correlator that is used to process VLBA data. Using the VLBA for this type of experiment offers significant advantages over single-dish experiments, including a larger field of view, the ability to easily distinguish local radio-frequency interference from real signals, and the possibility to localize detected events on the sky to milliarcsecond accuracy. We describe our software pipeline, which accepts short integration (∼ ms) spectrometer data from each antenna in real time during correlation and performs an incoherent dedispersion separately for each antenna, over a range of trial dispersion measures. The dedispersed data are processed by a sophisticated detector and candidate events are recorded. At the end of the correlation, small snippets of the raw data at the time of the events are stored for further analysis. We present the results of our event detection pipeline from some test observations of the pulsars B0329+54 and B0531+21 (the Crab pulsar).

  18. Technology, Empowerment and Community Radio

    OpenAIRE

    Salvatore Scifo

    2015-01-01

    This article will provide an overview of the conceptual contours of community media and community radio, highlighting some of the key questions shaping the debate and, with the help of a case study, show how digital media in the context of community radio can help local groups to get a voice in their local media systems, and how a university-based radio station, and its students and volunteers, play an important role for a more diverse and vibrant media content available in their area.

  19. Introduction to international radio regulations

    International Nuclear Information System (INIS)

    Struzak, R.

    2003-01-01

    These notes introduce the ITU Radio Regulations and related UN and WTO agreements that specify how terrestrial and satellite radio should be used in all countries over the planet. Access to the existing information infrastructure, and to that of the future Information Society, depends critically on these regulations. The paper also discusses few problems related to the use of the radio frequencies and satellite orbits. The notes are extracted from a book under preparation, in which these issues are discussed in more detail. (author)

  20. Magnetogasdynamics of double radio sources

    International Nuclear Information System (INIS)

    Nepveu, M.

    1979-01-01

    The magnetogasdynamical behaviour of plasmoids moving through an ambient gas is investigated numerically with a two-dimensional code, based on the SHASTA scheme. The astrophysical importance of this study lies in the observed extended extragalactic radio sources. It is assumed that plasma clouds with cylinder symmetry are ejected from the nucleus of a galaxy. Their large-scale evolution in the intergalactic medium (IGM) is followed. The gas dynamics of an ejected cloud, the magnetogasdynamics of ejected clouds, the Christiansen-Pacholczyk-Scott picture for radio galaxies and the shear layers in double radio sources are studied. (Auth.)